WorldWideScience

Sample records for high frequency measurements

  1. Low frequency phase signal measurement with high frequency squeezing

    OpenAIRE

    Zhai, Zehui; Gao, Jiangrui

    2011-01-01

    We calculate the utility of high-frequency squeezed-state enhanced two-frequency interferometry for low-frequency phase measurement. To use the high-frequency sidebands of the squeezed light, a two-frequency intense laser is used in the interferometry instead of a single-frequency laser as usual. We find that the readout signal can be contaminated by the high-frequency phase vibration, but this is easy to check and avoid. A proof-of-principle experiment is in the reach of modern quantum optic...

  2. An inkjet vision measurement technique for high-frequency jetting

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kye-Si, E-mail: kskwon@sch.ac.kr; Jang, Min-Hyuck; Park, Ha Yeong [Department of Mechanical Engineering, Soonchunhyang University 22, Soonchunhyang-Ro, Shinchang, Asan Chungnam 336-745 (Korea, Republic of); Ko, Hyun-Seok [Department of Electrical and Robot Engineering, Soonchunhyang University, 22, Soonchunhyang-Ro, Shinchang, Asan Chungnam 336-745 (Korea, Republic of)

    2014-06-15

    Inkjet technology has been used as manufacturing a tool for printed electronics. To increase the productivity, the jetting frequency needs to be increased. When using high-frequency jetting, the printed pattern quality could be non-uniform since the jetting performance characteristics including the jetting speed and droplet volume could vary significantly with increases in jet frequency. Therefore, high-frequency jetting behavior must be evaluated properly for improvement. However, it is difficult to measure high-frequency jetting behavior using previous vision analysis methods, because subsequent droplets are close or even merged. In this paper, we present vision measurement techniques to evaluate the drop formation of high-frequency jetting. The proposed method is based on tracking target droplets such that subsequent droplets can be excluded in the image analysis by focusing on the target droplet. Finally, a frequency sweeping method for jetting speed and droplet volume is presented to understand the overall jetting frequency effects on jetting performance.

  3. Modelling and measurement of high switching frequency conducted EMI

    CSIR Research Space (South Africa)

    Grobler, Inus

    2013-11-01

    Full Text Available High density high switching frequency power converter conducted EMC had been analysed, modelling the noise source and noise path, while providing accurate conducted EMC noise levels comparable to accredited noise measurements up to 100 MHz...

  4. Self-integrating inductive loop for measuring high frequency pulses.

    Science.gov (United States)

    Rojas-Moreno, Mónica V; Robles, Guillermo; Martínez-Tarifa, Juan M; Sanz-Feito, Javier

    2011-08-01

    High frequency pulses can be measured by means of inductive sensors. The main advantage of these sensors consists of non-contact measurements that isolate and protect measuring equipment. The objective of this paper is to present the implementation of an inductive sensor for measuring rapidly varying currents. It consists of a rectangular loop with a resistor at its terminals. The inductive loop gives the derivative of the current according to Faraday's law and the resistor connected to the loop modifies the sensor's frequency response to obtain an output proportional to the current pulse. The self-integrating inductive sensor was validated with two sensors, a non-inductive resistor and a commercial high frequency current transformer. The results were compared to determine the advantages and drawbacks of the probe as an adequate inductive transducer.

  5. High Frequency Modulation Method for Measuring of Birefringence

    Directory of Open Access Journals (Sweden)

    Šulc M.

    2013-05-01

    Full Text Available A method of optical birefringence measurement is presented. It uses an el ectro-optic modulator for the high frequency modulation of polarization of the laser beam. The developed optical apparatus exhibits high sensitivity. It is able to measure very small birefringence of samples down to 10-3 rad. The accuracy and sensitivity of the method was checked by measurement of calibrated Sol eil – Babi net compensator. Method can be also used for online and accurate measurement of an optical components birefringence. This application was developed with the aim to measure Cotton-Mouton effect in air and nitrogen.

  6. High temporal frequency measurements of greenhouse gas emissions from soils

    Science.gov (United States)

    Savage, K.; Phillips, R.; Davidson, E.

    2014-05-01

    Carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O) are the most important anthropogenic greenhouse gases (GHGs). Variation in soil moisture can be very dynamic, and it is one of the dominant factors controlling the net exchange of these three GHGs. Although technologies for high-frequency, precise measurements of CO2 have been available for years, methods for measuring soil fluxes of CH4 and N2O at high temporal frequency have been hampered by lack of appropriate technology for in situ real-time measurements. A previously developed automated chamber system for measuring CO2 flux from soils was configured to run in line with a new quantum cascade laser (QCLAS) instrument that measures N2O and CH4. Here we present data from a forested wetland in Maine and an agricultural field in North Dakota, which provided examples of both net uptake and production for N2O and CH4. The objective was to provide a range of conditions in which to run the new system and to compare results to a traditional manual static-chamber method. The high-precision and more-than-10-times-lower minimum detectable flux of the QCLAS system, compared to the manual system, provided confidence in measurements of small N2O uptake in the forested wetland. At the agricultural field, the greatest difference between the automated and manual sampling systems came from the effect of the relatively infrequent manual sampling of the high spatial variation, or "hot spots", in GHG fluxes. Hot spots greatly influenced the seasonal estimates, particularly for N2O, over one 74-day alfalfa crop cycle. The high temporal frequency of the automated system clearly characterized the transient response of all three GHGs to precipitation and demonstrated a clear diel pattern related to temperature for GHGs. A combination of high-frequency automated and spatially distributed chambers would be ideal for characterizing hot spots and "hot moments" of GHG fluxes.

  7. High frequency microphone measurements for transition detection on airfoils

    Energy Technology Data Exchange (ETDEWEB)

    Doessing, M.

    2008-05-15

    Time series of pressure fluctuations has been obtained using high frequency microphones distributed over the surface of airfoils undergoing wind tunnel tests in the LM Windtunnel, owned by 'LM Glasfiber', Denmark. The present report describes the dataanalysis, with special attention given to transition detection. It is argued that the transition point can be detected by observing the increase in the mean of the Fourier spectre and that thismethod is very stable froma numerical point of view. Other important issues are also discussed, e.g. the variation of pressure standard deviations (sound pressure) and Tollmien-Schlichting frequencies. The tests were made at Reynolds and Mach numbers corresponding to the operating conditions of a typical horizontal axis wind turbine (HAWT). The Risoe B1-18, Risoe C2-18 and NACA0015 profiles were tested and the measured transition points are reported. (au)

  8. Condenser Microphone Protective Grid Correction for High Frequency Measurements

    Science.gov (United States)

    Lee, Erik; Bennett, Reginald

    2010-01-01

    Use of a protective grid on small diameter microphones can prolong the lifetime of the unit, but the high frequency effects can complicate data interpretation. Analytical methods have been developed to correct for the grid effect at high frequencies. Specifically, the analysis pertains to quantifying the microphone protective grid response characteristics in the acoustic near field of a rocket plume noise source. A frequency response function computation using two microphones will be explained. Experimental and instrumentation setup details will be provided. The resulting frequency response function for a B&K 4944 condenser microphone protective grid will be presented, along with associated uncertainties

  9. Collective Thomson scattering measurements with high frequency resolution at TEXTOR

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Nielsen, Stefan Kragh; Korsholm, Søren Bang

    2010-01-01

    We discuss the development and first results of a receiver system for the collective Thomson scattering (CTS) diagnostic at TEXTOR with frequency resolution in the megahertz range or better. The improved frequency resolution expands the diagnostic range and utility of CTS measurements in general...

  10. Radar and Laser Sensors for High Frequency Ocean Wave Measurement.

    Science.gov (United States)

    Kennedy, C. R.

    2016-02-01

    Experimental measurement of air-sea fluxes invariably take place using shipbourne instrumentation and simultaneous measurement of wave height and direction is desired. A number of researchers have shown that range measuring sensors combined with inertial motion compensation can be successful on board stationary or very slowly moving ships. In order to measure wave characteristics from ships moving at moderate to full speed the sensors are required to operate at higher frequency so as to overcome the Doppler shift caused by ship motion. This work presents results from some preliminary testing of laser, radar and ultrasonic range sensors in the laboratory and on board ship. The characteristics of the individual sensors are discussed and comparison of the wave spectra produced by each is presented.

  11. High frequency electric field levels: An example of determination of measurement uncertainty for broadband measurements

    Directory of Open Access Journals (Sweden)

    Vulević Branislav

    2016-01-01

    Full Text Available Determining high frequency electromagnetic field levels in urban areas represents a very complex task, having in mind the exponential growth of the number of sources embodied in public cellular telephony systems in the past twenty years. The main goal of this paper is a representation of a practical solution in the evaluation of measurement uncertainty for in-situ measurements in the case of spatial averaging. An example of the estimation of the uncertainty for electric field strength broadband measurements in the frequency range from 3 MHz to 18 GHz is presented.

  12. High frequency microphone measurements for transition detection on airfoils

    DEFF Research Database (Denmark)

    Døssing, Mads

    Time series of pressure fluctuations has been obtained using high frequency microphones distributed over the surface of airfoils undergoing wind tunnel tests in the LM Windtunnel, owned by ’LM Glasfiber’, Denmark. The present report describes the dataanalysis, with special attention given...... to transition detection. It is argued that the transition point can be detected by observing the increase in the mean of the Fourier spectre and that thismethod is very stable froma numerical point of view. Other important issues are also discussed, e.g. the variation of pressure standard deviations (sound...

  13. High frequency, realtime measurements of stable isotopes in liquid water

    Science.gov (United States)

    Weiler, M.; Herbstritt, B.; Gralher, B.

    2012-04-01

    We developed a method to measure in-situ the isotopic composition of liquid water with minimal supervision and, most important, with a temporal resolution of less than a minute. For this purpose a off-the-shelf microporous hydrophobic membrane contactor for under 200€ was combined with an isotope laser spectrometer (Picarro). The contactor, originally designed for degassing liquids, was used with nitrogen as carrier gas in order to transform a small fraction of liquid water to water vapor. The generated water vapor was then analyzed continuously by the isotope laser spectrometer. To prove the membrane's applicability we determined the specific isotope fractionation factor for the phase change through the contactor's membrane for a common temperature range and with different waters of known isotopic compositions. This fractionation factor is then used to derive the liquid water isotope ratio from the measured water vapor isotope ratios and the measured temperature at the phase change. The system was compared for breakthrough curves of isotopically enriched water and the isotope values corresponded very well with those of liquid water samples taken simultaneously and analyzed with a conventional method (CRDS). The introduced method supersedes taking liquid samples and employs only relative cheap and readily available components. This makes it a relatively inexpensive, fast, user-friendly and easily reproducible method. It can be applied in both the field and laboratory wherever a water vapor isotope analyzer can be run and whenever real-time isotope data of liquid water are required at high temporal resolution with the same accuracy as collecting individual water samples.

  14. Novel, high sensitivity and high frequency instruments for in-situ measurements of volcanic gases

    Science.gov (United States)

    Burton, Mike; Chiarugi, Antonio; D'Amato, Francesco; Viciani, Silvia; Queisser, Manuel; La Spina, Alessandro

    2017-04-01

    The accurate, precise and traceable measurement of volcanic gas compositions and fluxes is a key pillar upon which our understanding of volcanic processes and geological volatile cycles rests. While enormous progress has been made in the quality and quantity of in-situ gas composition measurements in recent years, the number of instruments which are both field deployable and able to accurately measure magmatic gas compositions remains quite limited. This makes intercomparisons and validations, key activities for any quantitative field study, challenging. Furthermore, the potential of UAV and airborne technology can only be fully realised when we have high frequency measurements of volcanic gases from several gas sensors simultaneously, as gas concentrations can vary quickly during flight, and any frequency response delay between individual gas sensors may introduce significant artifacts in retrieved gas ratios. For these reasons, within the European Research Council project CO2Volc, we have produced and field-tested new, custom-built TDLS- and LED-based in-situ gas sensing systems, capable of measuring H2O, CO2, SO2, HCl and HF at 5-10 Hz and sub-ppm precision for CO2 and SO2, and 50 ppb detection limit for HCl and HF. Here, we report results from the field tests, and examine the potential new applications they offer.

  15. Determining of the electric field strength using high frequency broadband measurements

    OpenAIRE

    Vulević, Branislav D.

    2017-01-01

    Exposure of humans to electromagnetic fields of high frequency (above 100 kHz), i.e. radiofrequency radiation from the modern wireless systems, today inevitable is. The purpose of this paper is to highlight the importance of broadband measurements of the electric field of high frequency in order to fast and reliable assessment of human exposure. A practical method of ‘in situ’ measurement the electric field intensity which is related to the frequency range of 3 MHz to 18 GHz, is provided.

  16. High-frequency phosphorus and nitrate measurements for improved statutory water quality monitoring and management

    Science.gov (United States)

    Bieroza, Magdalena

    2017-04-01

    High-frequency nutrient (phosphorus and nitrogen) monitoring using wet-chemistry analysers and optical sensors has revolutionised the collection of biogeochemical data from streams, rivers and lakes. Matching the nutrient measurement time with timescales of hydrological responses has revealed biogeochemical patterns and nutrient hydrological responses not observed previously. Capturing a wider range of nutrient concentrations compared to traditional coarse resolution sampling enables more accurate estimation of mean concentrations and loads and thus improved water body classification. However, to date the scientific insights from the high-frequency nutrient monitoring studies have not been translated into policy and operational responses. The pertinent question is where and how often to measure nutrients to satisfy statutory monitoring requirements for the Water Framework Directive and the Nitrates Directive. Therefore this paper discusses how the reduced data uncertainty and improved process understanding obtained with the high-frequency measurements can improve statutory nutrient monitoring, using case studies from England and Sweden.

  17. First Measurements of High Frequency Cross-Spectra from a Pair of Large Michelson Interferometers

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Aaron S.; Gustafson, Richard; Hogan, Craig; Kamai, Brittany; Kwon, Ohkyung; Lanza, Robert; McCuller, Lee; Meyer, Stephan S.; Richardson, Jonathan; Stoughton, Chris; Tomlin, Raymond; Waldman, Samuel; Weiss, Rainer

    2016-09-01

    Measurements are reported of high frequency cross-spectra of signals from the Fermilab Holometer, a pair of co-located 39 m, high power Michelson interferometers. The instrument obtains differential position sensitivity to cross-correlated signals far exceeding any previous measurement in a broad frequency band extending to the 3.8 MHz inverse light crossing time of the apparatus. A model of universal exotic spatial shear correlations that matches the Planck scale holographic information bound of space-time position states is excluded to 4.6{\\sigma} significance.

  18. Calorimetric Measuring Systems for Characterizing High Frequency Power Losses in Power Electronic Components and Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Pedersen, John Kim; Ritchie, Andrew Ewen

    2002-01-01

    High frequency power losses in power electronic components and systems are very difficult to measure. The same applies to the efficiency of high-efficiency systems and components. An important method to measure losses with high accuracy is the calorimetric measuring systems. This paper describes...... two different calorimetric measuring systems, one for power losses up to 50 W and one for power losses up to 1500 W. These differ in size and also the systems which can be analysed. The basic concept of calorimetry is discussed and the overall performance of the two systems is specified. Methods...

  19. Upgrading a high-throughput spectrometer for high-frequency (<400 kHz) measurements

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, T., E-mail: nishizawa@wisc.edu; Nornberg, M. D.; Den Hartog, D. J. [University of Wisconsin–Madison, Madison, Wisconsin 53706 (United States); Craig, D. [Wheaton College, Wheaton, Illinois 60187 (United States)

    2016-11-15

    The upgraded spectrometer used for charge exchange recombination spectroscopy on the Madison Symmetric Torus resolves emission fluctuations up to 400 kHz. The transimpedance amplifier’s cutoff frequency was increased based upon simulations comparing the change in the measured photon counts for time-dynamic signals. We modeled each signal-processing stage of the diagnostic and scanned the filtering frequency to quantify the uncertainty in the photon counting rate. This modeling showed that uncertainties can be calculated based on assuming each amplification stage is a Poisson process and by calibrating the photon counting rate with a DC light source to address additional variation.

  20. Reference-free, high-resolution measurement method of timing jitter spectra of optical frequency combs

    Science.gov (United States)

    Kwon, Dohyeon; Jeon, Chan-Gi; Shin, Junho; Heo, Myoung-Sun; Park, Sang Eon; Song, Youjian; Kim, Jungwon

    2017-01-01

    Timing jitter is one of the most important properties of femtosecond mode-locked lasers and optical frequency combs. Accurate measurement of timing jitter power spectral density (PSD) is a critical prerequisite for optimizing overall noise performance and further advancing comb applications both in the time and frequency domains. Commonly used jitter measurement methods require a reference mode-locked laser with timing jitter similar to or lower than that of the laser-under-test, which is a demanding requirement for many laser laboratories, and/or have limited measurement resolution. Here we show a high-resolution and reference-source-free measurement method of timing jitter spectra of optical frequency combs using an optical fibre delay line and optical carrier interference. The demonstrated method works well for both mode-locked oscillators and supercontinua, with 2 × 10-9 fs2/Hz (equivalent to -174 dBc/Hz at 10-GHz carrier frequency) measurement noise floor. The demonstrated method can serve as a simple and powerful characterization tool for timing jitter PSDs of various comb sources including mode-locked oscillators, supercontinua and recently emerging Kerr-frequency combs; the jitter measurement results enabled by our method will provide new insights for understanding and optimizing timing noise in such comb sources.

  1. High-frequency measurements of aeolian saltation flux: Field-based methodology and applications

    Science.gov (United States)

    Martin, Raleigh L.; Kok, Jasper F.; Hugenholtz, Chris H.; Barchyn, Thomas E.; Chamecki, Marcelo; Ellis, Jean T.

    2018-02-01

    Aeolian transport of sand and dust is driven by turbulent winds that fluctuate over a broad range of temporal and spatial scales. However, commonly used aeolian transport models do not explicitly account for such fluctuations, likely contributing to substantial discrepancies between models and measurements. Underlying this problem is the absence of accurate sand flux measurements at the short time scales at which wind speed fluctuates. Here, we draw on extensive field measurements of aeolian saltation to develop a methodology for generating high-frequency (up to 25 Hz) time series of total (vertically-integrated) saltation flux, namely by calibrating high-frequency (HF) particle counts to low-frequency (LF) flux measurements. The methodology follows four steps: (1) fit exponential curves to vertical profiles of saltation flux from LF saltation traps, (2) determine empirical calibration factors through comparison of LF exponential fits to HF number counts over concurrent time intervals, (3) apply these calibration factors to subsamples of the saltation count time series to obtain HF height-specific saltation fluxes, and (4) aggregate the calibrated HF height-specific saltation fluxes into estimates of total saltation fluxes. When coupled to high-frequency measurements of wind velocity, this methodology offers new opportunities for understanding how aeolian saltation dynamics respond to variability in driving winds over time scales from tens of milliseconds to days.

  2. Broadband measurements of high-frequency electric field levels and exposure ratios determination

    Directory of Open Access Journals (Sweden)

    Vulević Branislav

    2017-01-01

    Full Text Available The exposure of people to high-frequency electromagnetic fields (over 100 kHz that emanate from modern wireless information transmission systems is inevitable in modern times. Due to the rapid development of new technologies, measuring devices and their connection to measuring systems, the first fifteen years of the 21st century are characterized by the appearance of different approaches to measurements. This prompts the need for the assessment of the exposure of people to these fields. The main purpose of this paper is to show how to determine the exposure ratios based on the results of broadband measurements of the high-frequency electric field in the range of 3 MHz to 18 GHz in the environment.

  3. An impedance bridge measuring the capacitance ratio in the high frequency range up to 1 MHz

    Science.gov (United States)

    Bee Kim, Dan; Kew Lee, Hyung; Kim, Wan-Seop

    2017-02-01

    This paper describes a 2-terminal-pair impedance bridge, measuring the capacitance ratio in the high frequency range up to 1 MHz. The bridge was configured with two voltage sources and a phase control unit which enabled the bridge balance by synchronizing the voltage sources with an enhanced phase resolution. Without employing the transformers such as inductive voltage divider, injection and detection transformers, etc, the bridge system is quite simple to set up, and the balance procedure is quick and easy. Using this dual-source coaxial bridge, the 1:1 and 10:1 capacitance ratios were measured with 1 pF-1 nF capacitors in the frequency range from 1 kHz to 1 MHz. The measurement values obtained by the dual-source bridge were then compared with reference values measured using a commercial precision capacitance bridge of AH2700A, the Z-matrix method developed by ourselves, and the 4-terminal-pair coaxial bridge by the Czech Metrological Institute. All the measurements agreed within the reference uncertainty range of an order of 10-6-10-5, proving the bridge ability as a trustworthy tool for measuring the capacitance ratio in the high frequency range.

  4. Study on technology of high-frequency pulsed magnetic field strength measurement.

    Science.gov (United States)

    Chen, Yi-Mei; Liu, Zhi-Peng; Yin, Tao

    2012-01-01

    High-frequency transient weak magnetic field is always involved in researches about biomedical engineering field while common magnetic-field sensors cannot work properly at frequencies as high as MHz. To measure the value of MHz-level weak pulsed magnetic-field strength accurately, this paper designs a measurement and calibration method for pulsed magnetic-field. In this paper, a device made of Nonferromagnetic material was independently designed and applied to pulsed magnetic field measurement. It held an accurately relative position between the magnetic field generating coil and the detecting coil. By applying a sinusoidal pulse to the generator, collecting the induced electromotive force of the detector, the final magnetic field strength was worked out through algorithms written in Matlab according to Faraday's Law. Experiments were carried out for measurement and calibration. Experiments showed that, under good stability and consistency, accurate measurement of magnetic-field strength of a sinepulse magnetic-field can be achieved, with frequency at 0.5, 1, 1.5 MHz and strength level at micro-Tesla. Calibration results carried out a measuring relative error about 2.5%.

  5. High-accuracy Brillouin frequency shift measurement system based on stimulated Brillouin scattering phase shift

    Science.gov (United States)

    Li, Yongqian; An, Qi; Li, Xiaojuan; Zhang, Lixin

    2017-05-01

    A high-accuracy Brillouin frequency shift (BFS) measurement system for vector Brillouin optical time-domain analysis-based temperature sensor is proposed, in which double sideband modulation is used and the stimulated Brillouin scattering (SBS) gain and loss processes work together to generate a superimposed SBS phase-shift spectrum. The measurement principle is analyzed by mathematical modeling and the proof-of-concept experiment is performed by using a 100-m long standard single-mode fiber. The theoretical and experimental results reveal that the temperature sensitivity of BFS obtained from the measured SBS phase-shift spectrum is 1.059 MHz/°C, and the measurement error of temperature is only half that in traditional single sideband-based system, which indicates that the proposed technique can realize high-accuracy temperature measurement and have huge potential in the field of long-distance and high-accuracy sensing.

  6. Investigating DOC export dynamics using high-frequency instream concentration measurements

    Science.gov (United States)

    Oosterwoud, Marieke; Keller, Toralf; Musolff, Andreas; Frei, Sven; Park, Ji-Hyung; Fleckenstein, Jan H.

    2014-05-01

    Being able to monitor DOC concentrations using in-situ high frequency measurements makes it possible to better understand concentration-discharge behavior under different hydrological conditions. We developed a UV-Vis probe setup for modified/adapted use under field conditions. The quasi mobile probe setup allows a more flexible probe deployment. New or existing monitoring sites can easily be equipped for quasi-continuous monitoring or measurements can be performed at changing locations, without the need for additional infrastructure. We were able to gather high frequency data on DOC dynamics for one year in two streams in the Harz mountains in Germany. It proved that obtaining accurate DOC concentrations from the UV-Vis probes required frequent maintenance and probe calibration. The advantage of the setup over standard monitoring protocols becomes evident when comparing net exports over a year. In addition to mass improved balance calculations the high-frequency measurements can reveal intricate hysteretic relationships between discharge and concentrations that can provide valuable insights into the hydrologic dynamics and mechanisms that govern the delivery of DOC to the receiving waters. Measurements with similar probes from two additional catchments in Southern Germany and South Korea will be used to illustrate different discharge-concentration relationships and what can be learned from them about the hydrologic mechanisms that control the dynamics of DOC export.

  7. Speckle interferometric sensor to measure low-amplitude high frequency Ocular Microtremor (OMT)

    Science.gov (United States)

    Ryle, James P.; Al-Kalbani, Mohammed; Gopinathan, Unnikrishnan; Boyle, Gerard; Coakley, Davis; Sheridan, John T.

    2009-08-01

    Ocular microtremor (OMT) is a physiological high frequency (up to 150Hz) low amplitude (150-2500nm) involuntary tremor of the human eye. It is one of the three fixational ocular motions described by Adler and Fliegelman in 1934 as well as microsaccades and drift. Clinical OMT investigations to date have used eye-contacting piezoelectric probes or piezoelectric strain gauges. Before contact can be made, the eye must first be anaesthetised. In some cases, this induces eyelid spasms (blepharospasm) making it impossible to measure OMT. Using the contact probe method, the eye motion is mechanically damped. In addition to this, it is not possible to obtain exact information about the displacement. Results from clinical studies to date have given electrical signal amplitudes from the probe. Recent studies suggest a number of clinical applications for OMT, these include monitoring the depth of anaesthesia of a patient in surgery, prediction of outcome in coma, diagnosis of brainstem death. In addition to this, abnormal OMT frequency content is present in patients with neurological disorders such as Multiple sclerosis and Parkinson's disease. However for ongoing clinical investigations the contact probe method falls short of a non-contact accurate measurement solution. In this paper, we design a compact non contact phase modulating optical fiber speckle interferometer to measure eye motions. We present our calibration results using a calibrated piezoelectric vibration simulator. Digital signal processing is then performed to extract the low amplitude high frequency displacement information.

  8. Working Fluid State Properties Measurements in Medium and High Frequency Cryocoolers

    Science.gov (United States)

    Roberts, Thomas P.; Desai, Prateen V.

    2004-06-01

    The measurement of the internal thermodynamic states in operational cryocoolers has been an experimental challenge of long standing. An experimental data acquisition system is described which uses high frequency pressure and hot wire anemometry transducers to measure the pressure, temperature, and mass flow within a working Stirling cycle refrigerator operating in the 20 to 60 hertz frequency range. Problems with establishing refrigerator hermeticity and instrumentation calibrations are discussed and the solutions which were used are detailed. A subset of the empirical data obtained by the experimental effort is shown in order to demonstrate how working fluid equations of state can be used to describe refrigeration component performance and estimate how components contribute to overall system characteristics.

  9. Time resolved measurements of cathode fall in high frequency fluorescent lamps

    Science.gov (United States)

    Hadrath, S.; Garner, R. C.; Lieder, G. H.; Ehlbeck, J.

    2007-11-01

    Measurements are presented of the time resolved cathode and anode falls of high frequency fluorescent lamps for a range of discharge currents typically encountered in dimming mode. Measurements were performed with the movable anode technique. Supporting spectroscopic emission measurements were made of key transitions (argon 420.1 nm and mercury 435.8 nm), whose onset coincide with cathode fall equalling the value associated with the energy, relative to the ground state, of the upper level of the respective transition. The measurements are in general agreement with the well-known understanding of dimmed lamp operation: peak cathode fall decreases with increasing lamp current and with increasing auxiliary coil heating. However, the time dependence of the measurements offers additional insight.

  10. Time resolved measurements of cathode fall in high frequency fluorescent lamps

    Energy Technology Data Exchange (ETDEWEB)

    Hadrath, S [Institute of Low-Temperature Plasma Physics, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany); Garner, R C [Central Research and Services Laboratory, OSRAM Sylvania, 71 Cherry Hill Dr, Beverly, MA 01915 (United States); Lieder, G H [Research Light Sources, Osram GmbH, Hellabrunner Str. 1, D-81536 Munich (Germany); Ehlbeck, J [Institute of Low-Temperature Plasma Physics, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany)

    2007-11-21

    Measurements are presented of the time resolved cathode and anode falls of high frequency fluorescent lamps for a range of discharge currents typically encountered in dimming mode. Measurements were performed with the movable anode technique. Supporting spectroscopic emission measurements were made of key transitions (argon 420.1 nm and mercury 435.8 nm), whose onset coincide with cathode fall equalling the value associated with the energy, relative to the ground state, of the upper level of the respective transition. The measurements are in general agreement with the well-known understanding of dimmed lamp operation: peak cathode fall decreases with increasing lamp current and with increasing auxiliary coil heating. However, the time dependence of the measurements offers additional insight.

  11. In vivo measurement of basilar membrane vibration in the unopened chinchilla cochlea using high frequency ultrasound.

    Science.gov (United States)

    Landry, Thomas G; Bance, Manohar L; Leadbetter, Jeffrey; Adamson, Robert B; Brown, Jeremy A

    2017-06-01

    The basilar membrane and organ of Corti in the cochlea are essential for sound detection and frequency discrimination in normal hearing. There are currently no methods used for real-time high resolution clinical imaging or vibrometry of these structures. The ability to perform such imaging could aid in the diagnosis of some pathologies and advance understanding of the causes. It is demonstrated that high frequency ultrasound can be used to measure basilar membrane vibrations through the round window of chinchilla cochleas in vivo. The basic vibration characteristics of the basilar membrane agree with previous studies that used other methods, although as expected, the sensitivity of ultrasound was not as high as optical methods. At the best frequency for the recording location, the average vibration velocity amplitude was about 4 mm/s/Pa with stimulus intensity of 50 dB sound pressure level. The displacement noise floor was about 0.4 nm with 256 trial averages (5.12 ms per trial). Although vibration signals were observed, which likely originated from the organ of Corti, the spatial resolution was not adequate to resolve any of the sub-structures. Improvements to the ultrasound probe design may improve resolution and allow the responses of these different structures to be better discriminated.

  12. High frequency BJT: modeling, and parameter extraction from simple measurements on encapsulated devices

    Science.gov (United States)

    Karmalkar, S.; Chandra, A. Sharat

    2003-01-01

    This paper develops measurement procedures for extracting the critical structural parameters of an encapsulated high frequency bipolar transistor from simple measurements. Encapsulated devices can be readily handled and included in a test set up, and the present work obviates the need to fabricate and measure separate simpler test structures for parameter extraction. The parameters extracted are: emitter stripe width and area, epitaxial collector doping, resistivity and width, emitter and collector junction depths, peak base doping, impurity gradient of the emitter junction, oxide thickness and fixed charge, and package parasitic capacitances. The material parameters and the readily observable planar dimensions such as emitter stripe length and metal pad areas are used as input parameters in the extraction procedure. The work re-inforces recent insights into the nature of current flow across the epitaxial collector width of a real device at the onset of base widening effects, as the terminal collector-base voltage is varied.

  13. High-frequency attenuation and backscatter measurements of rat blood between 30 and 60 MHz

    Science.gov (United States)

    Huang, Chih-Chung

    2010-10-01

    There has recently been a great deal of interest in noninvasive high-frequency ultrasound imaging of small animals such as rats due to their being the preferred animal model for gene therapy and cancer research. Improving the interpretation of the obtained images and furthering the development of the imaging devices require a detailed knowledge of the ultrasound attenuation and backscattering of biological tissue (e.g. blood) at high frequencies. In the present study, the attenuation and backscattering coefficients of the rat red blood cell (RBC) suspensions and whole blood with hematocrits ranging from 6% to 40% were measured between 30 and 60 MHz using a modified substitution approach. The acoustic parameters of porcine blood under the same conditions were also measured in order to compare differences in the blood properties between these two animals. For porcine blood, both whole blood and RBC suspension were stirred at a rotation speed of 200 rpm. Three different rotation speeds of 100, 200 and 300 rpm were carried out for rat blood experiments. The attenuation coefficients of both rat and porcine blood were found to increase linearly with frequency and hematocrit (the values of coefficients of determination (r2) are around 0.82-0.97 for all cases). The average attenuation coefficient of rat whole blood with a hematocrit of 40% increased from 0.26 Nepers mm-1 at 30 MHz to 0.47 Nepers mm-1 at 60 MHz. The maximum backscattering coefficients of both rat and porcine RBC suspensions were between 10% and 15% hematocrits at all frequencies. The fourth-power dependence of backscatter on frequency was approximately valid for rat RBC suspensions with hematocrits between 6% and 40%. However, the frequency dependence of the backscatter estimate deviates from a fourth-power law for porcine RBC suspension with hematocrit higher than 20%. The backscattering coefficient plateaued for hematocrits higher than 15% in porcine blood, but for rat blood it was maximal around a

  14. High-frequency attenuation and backscatter measurements of rat blood between 30 and 60 MHz

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chih-Chung, E-mail: j648816n@ms23.hinet.ne [Department of Electrical Engineering, Fu Jen Catholic University, Taipei, Taiwan (China)

    2010-10-07

    There has recently been a great deal of interest in noninvasive high-frequency ultrasound imaging of small animals such as rats due to their being the preferred animal model for gene therapy and cancer research. Improving the interpretation of the obtained images and furthering the development of the imaging devices require a detailed knowledge of the ultrasound attenuation and backscattering of biological tissue (e.g. blood) at high frequencies. In the present study, the attenuation and backscattering coefficients of the rat red blood cell (RBC) suspensions and whole blood with hematocrits ranging from 6% to 40% were measured between 30 and 60 MHz using a modified substitution approach. The acoustic parameters of porcine blood under the same conditions were also measured in order to compare differences in the blood properties between these two animals. For porcine blood, both whole blood and RBC suspension were stirred at a rotation speed of 200 rpm. Three different rotation speeds of 100, 200 and 300 rpm were carried out for rat blood experiments. The attenuation coefficients of both rat and porcine blood were found to increase linearly with frequency and hematocrit (the values of coefficients of determination (r{sup 2}) are around 0.82-0.97 for all cases). The average attenuation coefficient of rat whole blood with a hematocrit of 40% increased from 0.26 Nepers mm{sup -1} at 30 MHz to 0.47 Nepers mm{sup -1} at 60 MHz. The maximum backscattering coefficients of both rat and porcine RBC suspensions were between 10% and 15% hematocrits at all frequencies. The fourth-power dependence of backscatter on frequency was approximately valid for rat RBC suspensions with hematocrits between 6% and 40%. However, the frequency dependence of the backscatter estimate deviates from a fourth-power law for porcine RBC suspension with hematocrit higher than 20%. The backscattering coefficient plateaued for hematocrits higher than 15% in porcine blood, but for rat blood it was

  15. High accuracy microwave frequency measurement based on single-drive dual-parallel Mach-Zehnder modulator

    DEFF Research Database (Denmark)

    Zhao, Ying; Pang, Xiaodan; Deng, Lei

    2011-01-01

    A novel approach for broadband microwave frequency measurement by employing a single-drive dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. Based on bias manipulations of the modulator, conventional frequency-to-power mapping technique is developed by performing a...... 10−3 relative error. This high accuracy frequency measurement technique is a promising candidate for high-speed electronic warfare and defense applications....

  16. High-frequency phase shift measurement greatly enhances the sensitivity of QCM immunosensors.

    Science.gov (United States)

    March, Carmen; García, José V; Sánchez, Ángel; Arnau, Antonio; Jiménez, Yolanda; García, Pablo; Manclús, Juan J; Montoya, Ángel

    2015-03-15

    In spite of being widely used for in liquid biosensing applications, sensitivity improvement of conventional (5-20MHz) quartz crystal microbalance (QCM) sensors remains an unsolved challenging task. With the help of a new electronic characterization approach based on phase change measurements at a constant fixed frequency, a highly sensitive and versatile high fundamental frequency (HFF) QCM immunosensor has successfully been developed and tested for its use in pesticide (carbaryl and thiabendazole) analysis. The analytical performance of several immunosensors was compared in competitive immunoassays taking carbaryl insecticide as the model analyte. The highest sensitivity was exhibited by the 100MHz HFF-QCM carbaryl immunosensor. When results were compared with those reported for 9MHz QCM, analytical parameters clearly showed an improvement of one order of magnitude for sensitivity (estimated as the I50 value) and two orders of magnitude for the limit of detection (LOD): 30μgl(-1) vs 0.66μgL(-1)I50 value and 11μgL(-1) vs 0.14μgL(-1) LOD, for 9 and 100MHz, respectively. For the fungicide thiabendazole, I50 value was roughly the same as that previously reported for SPR under the same biochemical conditions, whereas LOD improved by a factor of 2. The analytical performance achieved by high frequency QCM immunosensors surpassed those of conventional QCM and SPR, closely approaching the most sensitive ELISAs. The developed 100MHz QCM immunosensor strongly improves sensitivity in biosensing, and therefore can be considered as a very promising new analytical tool for in liquid applications where highly sensitive detection is required. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. High-Frequency Pulsed-Electro-Acoustic (PEA) Measurements for Mapping Charge Distribution

    Science.gov (United States)

    Sorensen, Kristina; Pearson, Lee; Dennison, J. R.; Doyle, Timothy; Hartley, Kent

    2012-10-01

    High-frequency pulsed-electro-acoustic (PEA) measurements are a non-destructive method used to investigate internal charge distributions in dielectric materials. This presentation discusses the theory and signal processing of simple PEA experiments and shows results of PEA measurements. PEA experiments involve a thin dielectric positioned between two conducting electrodes. A voltage signal on the two electrodes generates an electric field across the dielectric, which stimulates embedded charge and creates a pressure wave that propagates within the capacitor. A coupled acoustic sensor then measures the ensuing pressure pulse response. Spatial distributions of the charge profile are obtained from the resultant pressure waveform. Gaussian filters and other signal processing methods are used to increase the signal-to-noise ratio in this waveform. Estimates of the charge distribution inside the dielectric are extracted from this analysis. Our ultimate objective is to develop high resolution PEA methods to investigate in vacuo charge deposition in thin film polymeric, ceramic, or glass dielectric materials using medium to high energy (approximately 103 to 107 eV) electron beams.

  18. Statistical Analysis of Thomson Scattering Measurements for High-Frequency Temperature Fluctuations

    Science.gov (United States)

    Morton, Lucas; den Hartog, Daniel; Parke, Eli; Duff, James; Lin, Liang

    2014-10-01

    The MST Thomson Scattering (TS) Diagnostic is used to study electron temperature (Te) fluctuations at frequencies (lasers can fire 4-5 pulses at repetition rate of 12.5 kHz. Adjusting the time delay between the lasers (as low as 1 μs) allows probing of high-frequency (up to 1 MHz) fluctuations by autocorrelating the resulting Te measurements. This technique's effectiveness is demonstrated by comparing its results to those of tearing-mode-correlation studies. In 400 kA standard MST discharges, the dominant tearing modes have associated Te fluctuations of up to 25 +/- 5eV in the core. The TS autocorrelation measures total fluctuations of 42 +/- 5eV, indicating that tearing comprises much of the core Te fluctuations. With improved laser alignment, we investigate 400 kA improved confinement (PPCD) plasmas where global tearing activity is reduced and electrostatic turbulence may dominate electron thermal transport and fluctuation power. We also find no significant Te fluctuation (<5eV) correlated with edge-localized density fluctuations seen by the FIR interferometer in 200kA PPCD plasmas. This work supported by the US DOE and NSF.

  19. High Frequency Transducer Dedicated to the High-resolution in Situ Measurement of the Distance between Two Nuclear Fuel Plates

    Science.gov (United States)

    Zaz, G.; Dekkious, A.; Meignen, P. A.; Calzavara, Y.; Le Clézio, E.; Despaux, G.

    Most high flux reactors for research purposes have fuel elements composed of plates and not pencils. The measure of inter-plate distance of a fuel element is tricky since a resolution of a micron is searched to measure plate swellings of about ten microns while the dimension between the plates is close to the millimeter. This measure should provide information about the fuel and particularly its history of irradiation. That is the reason why a solution has been considered: a robust device based upon high frequency ultrasonic probes adapted to the high radiation environment and thinned to 1 mm to be inserted into a 1.8 mm width water channel between two fuel plates. To achieve the expected resolution, the system is excited with frequencies up to 150 MHz. Thanks to a specific signal processing, this device allows the distance measurement through an ultrasonic wave's time of flight. The feasibility of such challenging distance measurement has already been proved with success on a full size irradiated fuel element of the RHF.

  20. Design and Measurement of Planar Toroidal Transformers for Very High Frequency Power Applications

    DEFF Research Database (Denmark)

    Knott, Arnold; Pejtersen, Jens

    2012-01-01

    -core toroidal transformer configuration for use in very high frequency power conversion applications. Two prototype transformers (10:10 and 12:12) have been implemented using conventional four layer printed circuit board technology. The transformers have been characterized by two port Z-parameters, which have...... power converters for very high frequencies. The magnetic coupling factor of both transformers is approx. 60 % and the mutual coupling inductance is dominant up to a frequency of 50 MHz.......The quest for higher power density has led to research of very high frequency (30-300 MHz) power converters. Magnetic components based on ferrite cores have limited application within this frequency range due to increased core loss. Air-core magnetics is a viable alternative as they do not exhibit...

  1. Beyond the frame rate: measuring high-frequency fluctuations with light-intensity modulation.

    Science.gov (United States)

    Wong, Wesley P; Halvorsen, Ken

    2009-02-01

    Power-spectral-density measurements of any sampled signal are typically restricted by both acquisition rate and frequency response limitations of instruments, which can be particularly prohibitive for video-based measurements. We have developed a new method called intensity modulation spectral analysis that circumvents these limitations, dramatically extending the effective detection bandwidth. We demonstrate this by video tracking an optically trapped microsphere while oscillating an LED illumination source. This approach allows us to quantify fluctuations of the microsphere at frequencies over 10 times higher than the Nyquist frequency, mimicking a significantly higher frame rate.

  2. A very low noise, high accuracy, programmable voltage source for low frequency noise measurements

    Science.gov (United States)

    Scandurra, Graziella; Giusi, Gino; Ciofi, Carmine

    2014-04-01

    In this paper an approach for designing a programmable, very low noise, high accuracy voltage source for biasing devices under test in low frequency noise measurements is proposed. The core of the system is a supercapacitor based two pole low pass filter used for filtering out the noise produced by a standard DA converter down to 100 mHz with an attenuation in excess of 40 dB. The high leakage current of the supercapacitors, however, introduces large DC errors that need to be compensated in order to obtain high accuracy as well as very low output noise. To this end, a proper circuit topology has been developed that allows to considerably reduce the effect of the supercapacitor leakage current on the DC response of the system while maintaining a very low level of output noise. With a proper design an output noise as low as the equivalent input voltage noise of the OP27 operational amplifier, used as the output buffer of the system, can be obtained with DC accuracies better that 0.05% up to the maximum output of 8 V. The expected performances of the proposed voltage source have been confirmed both by means of SPICE simulations and by means of measurements on actual prototypes. Turn on and stabilization times for the system are of the order of a few hundred seconds. These times are fully compatible with noise measurements down to 100 mHz, since measurement times of the order of several tens of minutes are required in any case in order to reduce the statistical error in the measured spectra down to an acceptable level.

  3. PD-Detection vs. Loss Measurements at High Voltages with variable frequencies

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Edin, Hans

    1999-01-01

    Partial discharge-activity (PD) in internal voids in epoxy plastic was measured at AC voltages from below inception to 3 times inception with variable frequencies in the range 0.1 to 100Hz.The results from phase/height analyses were compared to dielec-tric loss measurements and related to the app......Partial discharge-activity (PD) in internal voids in epoxy plastic was measured at AC voltages from below inception to 3 times inception with variable frequencies in the range 0.1 to 100Hz.The results from phase/height analyses were compared to dielec-tric loss measurements and related...

  4. Developments of the indirect method for measuring the high frequency dynamic stiffness of resilient elements

    NARCIS (Netherlands)

    Thompson, D.J.; Vliet, W.J. van; Verheij, J.W.

    1998-01-01

    The complex stiffness of resilient elements is an important parameter required in order to model vibration isolation for many applications. Measurement methods are being standardized which allow such a stiffness to be measured as a function of excitation frequency for known loading conditions. This

  5. Frequency Comb Driven Raman Transitions in the THz Range: High Precision Isotope Shift Measurements in Ca+

    DEFF Research Database (Denmark)

    Meyer, Steffen

    2017-01-01

    to picoseconds in the previous experiments. For the broad spectrum, the additional effect of group delay dispersion (GDD) has to be taken into account, since the Raman process relies on the coherent interaction of all frequency components of the spectrum, with GDD influencing the relative phase which leads......This thesis presents for the first time the experimental implementation of coherent Raman oscillations with a femtosecond frequency comb for transition frequencies in the THz range. The technique has been successfully demonstrated before to drive Raman transitions between hyperfine structure states...... to destructive interference. Therefore, GDD is compensated using a prism compressor and it is shown quantitatively that the measured GDD matches the theoretically predicted effect on the total Raman Rabi frequency. For the measurements and compensation of GDD, the techniques of interferometric autocorrelation...

  6. Measuring myofiber orientations from high-frequency ultrasound images using multiscale decompositions

    Science.gov (United States)

    Qin, Xulei; Fei, Baowei

    2014-07-01

    High-frequency ultrasound (HFU) has the ability to image both skeletal and cardiac muscles. The quantitative assessment of these myofiber orientations has a number of applications in both research and clinical examinations; however, difficulties arise due to the severe speckle noise contained in the HFU images. Thus, for the purpose of automatically measuring myofiber orientations from two-dimensional HFU images, we propose a two-step multiscale image decomposition method. It combines a nonlinear anisotropic diffusion filter and a coherence enhancing diffusion filter to extract myofibers. This method has been verified by ultrasound data from simulated phantoms, excised fiber phantoms, specimens of porcine hearts, and human skeletal muscles in vivo. The quantitative evaluations of both phantoms indicated that the myofiber measurements of our proposed method were more accurate than other methods. The myofiber orientations extracted from different layers of the porcine hearts matched the prediction of an established cardiac mode and demonstrated the feasibility of extracting cardiac myofiber orientations from HFU images ex vivo. Moreover, HFU also demonstrated the ability to measure myofiber orientations in vivo.

  7. High Frequency Acoustic Sensor Dedicated to the High Resolution Measurement of Mechanical Properties

    Science.gov (United States)

    Meignen, Pierre-Antoine; Le Clézio, Emmanuel; Despaux, Gilles

    Through acoustic signature, scanning acoustic microscopy can be used to quantify local mechanical properties of a medium thanks to the generation of surface waves, mostly Rayleigh waves. Despite being quite effective, this method requires to evaluate the mechanical properties of a single point the acquisition of many ultrasonic signals. This process is then time-consuming and is hardly adaptable to quantitative imaging. The solution considered in this paper to speed-up the method is to design a multi-element sensor allowing the extraction of information on Rayleigh waves with a reduced number of acquisitions. The work is conducted along two axes. As a first step, a model allowing the simulation of the acoustic wave behavior at a fluid/solid interface is developed. This model leads to a better understanding of the characterization of the mechanical properties and to the definition of an adapted sensor's design. As a second step, an experimental method for acoustic field reconstruction is used to characterize the multi-elements sensor and measurements of mechanical properties were done.

  8. Mitigation measures of electromagnetic field exposure in the vicinity of high frequency welders

    Directory of Open Access Journals (Sweden)

    Bartłomiej Zubrzak

    2017-12-01

    Full Text Available Background: Presented information about the welding process and equipment, focusing on the emission of electromagnetic field (EMF with levels significant in terms of the labor safety regulations in force in Poland – the ordinances of the Minister of Family, Labour and Social Policy that came into force on June 27, 2016 and June 29, 2016 – emerged due to harmonization with European Union directive 2013/35/EU of 26 June 2013 of the European Parliament and the Council. They presented methods of determination of the EMF distribution in the welding machine surroundings and analyzed the background knowledge from the available literature. Material and Methods: The subject of the analysis included popular high frequency welders widely used in the industry. Electromagnetic field measurements were performed in the welder operating place (in situ during machine normal operations, using measurement methods accordant with labor safety regulations in force in Poland and according to the same guidelines, the EMF distributions and parameters having been described. Results: They presented various scenarios of particular, real examples of excessive exposure to EMF in the dielectric welder surroundings and showed solutions, ranging from simple and costless and ending on dedicated electromagnetic shielding systems, which allowed to reduce EMF exposure in some cases of more than 80% (protection zone ranges or eliminate dangerous zone presence. Conclusions: It has shown that in the dielectric welders surrounding, significant EMF strength levels may be the result of errors or omissions which often occur during development, installation, operation or modification of welding machines. It has allowed to present the measures that may significantly reduce the exposure to EMF of workers in the welder surroundings. The role of accredited laboratories in helping in such cases was underlined. Med Pr 2017;68(6:693–703

  9. Mitigation measures of electromagnetic field exposure in the vicinity of high frequency welders.

    Science.gov (United States)

    Zubrzak, Bartłomiej; Bieńkowski, Paweł; Cała, Pawel

    2017-10-17

    Presented information about the welding process and equipment, focusing on the emission of electromagnetic field (EMF) with levels significant in terms of the labor safety regulations in force in Poland - the ordinances of the Minister of Family, Labour and Social Policy that came into force on June 27, 2016 and June 29, 2016 - emerged due to harmonization with European Union directive 2013/35/EU of 26 June 2013 of the European Parliament and the Council. They presented methods of determination of the EMF distribution in the welding machine surroundings and analyzed the background knowledge from the available literature. The subject of the analysis included popular high frequency welders widely used in the industry. Electromagnetic field measurements were performed in the welder operating place (in situ) during machine normal operations, using measurement methods accordant with labor safety regulations in force in Poland and according to the same guidelines, the EMF distributions and parameters having been described. They presented various scenarios of particular, real examples of excessive exposure to EMF in the dielectric welder surroundings and showed solutions, ranging from simple and costless and ending on dedicated electromagnetic shielding systems, which allowed to reduce EMF exposure in some cases of more than 80% (protection zone ranges) or eliminate dangerous zone presence. It has shown that in the dielectric welders surrounding, significant EMF strength levels may be the result of errors or omissions which often occur during development, installation, operation or modification of welding machines. It has allowed to present the measures that may significantly reduce the exposure to EMF of workers in the welder surroundings. The role of accredited laboratories in helping in such cases was underlined. Med Pr 2017;68(6):693-703.

  10. Simultaneous measurement of red blood cell aggregation and whole blood coagulation using high-frequency ultrasound.

    Science.gov (United States)

    Nam, Kweon-Ho; Yeom, Eunseop; Ha, Hojin; Lee, Sang Joon

    2012-03-01

    This study aims to investigate the feasibility of using high-frequency ultrasound (HFUS) for simultaneous monitoring of blood coagulation and red blood cell (RBC) aggregation. Using a 35-MHz ultrasound scanner, ultrasound speckle data were acquired from whole blood samples of three experimental groups of rats, including 4,4'-diisothiocyanatostilbene-2,2'-disulfonic acid (DIDS)-treated, noncoagulation and normal control groups. The variations of blood echogenicity, the shape parameters of probability distribution of speckle intensity (skewness and kurtosis) and the correlation coefficient between two consecutive speckle data were calculated as a function of time starting from immediately after taking blood. The blood echogenicity increases rapidly to plateaus at the early stage of measurement for all the experimental groups caused by the formation of RBC aggregates. The DIDS-treated group exhibits the lowest echogenicity level due to the inhibitory effect of DIDS on RBC aggregation. The correlation analysis between consecutive speckle patterns seems to be useful to examine the variation of blood fluidity and the progress of clot formation. Whole blood coagulation is observed to be accelerated by DIDS treatment. In addition, the results of skewness and kurtosis analysis indicated that RBC aggregates may be disrupted during blood coagulation. The present study suggests that HFUS has good potential for simultaneous monitoring of RBC aggregation and blood coagulation to examine the relationship between them. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. In Situ Acoustic Monitoring of Thermal Spray Process Using High-Frequency Impulse Measurements

    Science.gov (United States)

    Tillmann, Wolfgang; Walther, Frank; Luo, Weifeng; Haack, Matthias; Nellesen, Jens; Knyazeva, Marina

    2018-01-01

    In order to guarantee their protective function, thermal spray coatings must be free from cracks, which expose the substrate surface to, e.g., corrosive media. Cracks in thermal spray coatings are usually formed because of tensile residual stresses. Most commonly, the crack occurrence is determined after the thermal spraying process by examination of metallographic cross sections of the coating. Recent efforts focus on in situ monitoring of crack formation by means of acoustic emission analysis. However, the acoustic signals related to crack propagation can be absorbed by the noise of the thermal spraying process. In this work, a high-frequency impulse measurement technique was applied to separate different acoustic sources by visualizing the characteristic signal of crack formation via quasi-real-time Fourier analysis. The investigations were carried out on a twin wire arc spraying process, utilizing FeCrBSi as a coating material. The impact of the process parameters on the acoustic emission spectrum was studied. Acoustic emission analysis enables to obtain global and integral information on the formed cracks. The coating morphology and coating defects were inspected using light microscopy on metallographic cross sections. Additionally, the resulting crack patterns were imaged in 3D by means of x-ray microtomography.

  12. Seismic imaging of the shallow subsurface with high frequency seismic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kaelin, Bruno [Univ. of California, Berkeley, CA (United States). Dept. of Geology and Geophysics

    1998-07-01

    Elastic wave propagation in highly heterogeneous media is investigated and theoretical calculations and field measurements are presented. In the first part the dynamic composite elastic medium (DYCEM) theory is derived for one-dimensional stratified media. A self-consistent method using the scattering functions of the individual layers is formulated, which allows the calculation of phase velocity, attenuation and waveform. In the second part the DYCEM theory has been generalized for three-dimensional inclusions. The specific case of spherical inclusions is calculated with the exact scattering functions and compared with several low frequency approximations. In the third part log and VSP data of partially water saturated tuffs in the Yucca Mountain region of Nevada are analyzed. The anomalous slow seismic velocities can be explained by combining self-consistent theories for pores and cracks. The fourth part analyzes an air injection experiment in a shallow fractured limestone, which has shown large effects on the amplitude, but small effects on the travel time of the transmitted seismic waves. The large amplitude decrease during the experiment is mainly due to the impedance contrast between the small velocities of gas-water mixtures inside the fracture and the formation. The slow velocities inside the fracture allow an estimation of aperture and gas concentration profiles.

  13. Measurement of ciliary beat frequency using ultra-high resolution optical coherence tomography

    Science.gov (United States)

    Chen, Jason J.; Jing, Joseph C.; Su, Erica; Badger, Christopher; Coughlan, Carolyn A.; Chen, Zhongping; Wong, Brian J. F.

    2016-02-01

    Ciliated epithelial cells populate up to 80% of the surface area of the human airway and are responsible for mucociliary transport, which is the key protective mechanism that provides the first line of defense in the respiratory tract. Cilia beat in a rhythmic pattern and may be easily affected by allergens, pollutants, and pathogens, altering ciliary beat frequency (CBF) subsequently. Diseases including cystic fibrosis, chronic obstructive pulmonary disease, and primary ciliary dyskinesia may also decrease CBF. CBF is therefore a critical component of respiratory health. The current clinical method of measuring CBF is phase-contrast microscopy, which involves a tissue biopsy obtained via brushing of the nasal cavity. While this method is minimally invasive, the tissue sample must be oriented to display its profile view, making the visualization of a single layer of cilia challenging. In addition, the conventional method requires subjective analysis of CBF, e.g., manually counting by visual inspection. On the contrary, optical coherence tomography (OCT) has been used to study the retina in ophthalmology as well as vasculature in cardiology, and offers higher resolution than conventional computed tomography and magnetic resonance imaging. Based on this technology, our lab specifically developed an ultra-high resolution OCT system to image the microstructure of the ciliated epithelial cells. Doppler analysis was also performed to determine CBF. Lastly, we also developed a program that utilizes fast Fourier transform to determine CBF under phase-contrast microscopy, providing a more objective method compared to the current method.

  14. Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements

    Directory of Open Access Journals (Sweden)

    Kanellopoulos AJ

    2013-11-01

    Full Text Available Anastasios John Kanellopoulos,1,2 George Asimellis1 1Laservision.gr Eye Institute, Athens, Greece; 2New York University Medical School, New York, NY, USA Background: The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II, a spectral-domain anterior-segment optical coherence tomography (AS-OCT system, and a high-frequency ultrasound biomicroscopy (HF-UBM system. Methods: Fifty eyes randomly selected from 50 patients were included in the study. Inclusion criteria were healthy, nonoperated eyes examined consecutively by the same examiner. Corneal imaging was performed by three different methods, ie, Oculyzer II, spectral-domain AS-OCT, and FH-UBM. Central corneal thickness measurements were compared using scatter diagrams, Bland-Altman plots (with bias and 95% confidence intervals, and two-paired analysis. Results: The coefficient of determination (r2 between the Oculyzer II and AS-OCT measurements was 0.895. Likewise, the coefficient was 0.893 between the Oculyzer II and HF-UBM and 0.830 between the AS-OCT and HF-UBM. The trend line coefficients of linearity were 0.925 between the Oculyzer II and the AS-OCT, 1.006 between the Oculyzer II and HF-UBM, and 0.841 between the AS-OCT and HF-UBM. The differences in average corneal thickness between the three pairs of CCT measurements were –6.86 µm between the Oculyzer II and HF-UBM, –12.20 µm between the AS-OCT and Oculyzer II, and +19.06 µm between the HF-UBM and AS-OCT. Conclusion: The three methods used for corneal thickness measurement are highly correlated. Compared with the Scheimplug and ultrasound devices, the AS-OCT appears to report a more accurate, but overally thinner corneal pachymetry. Keywords: anterior eye segment, high-frequency ultrasound biomicroscopy, optical coherence tomography, high-resolution Pentacam

  15. High resolution kilometric range optical telemetry in air by radio frequency phase measurement

    Energy Technology Data Exchange (ETDEWEB)

    Guillory, Joffray; García-Márquez, Jorge; Truong, Daniel; Wallerand, Jean-Pierre [Laboratoire Commun de Métrologie LNE-Cnam (LCM), LNE, 1 rue Gaston Boissier, 75015 Paris (France); Šmíd, Radek [Laboratoire Commun de Métrologie LNE-Cnam (LCM), LNE, 1 rue Gaston Boissier, 75015 Paris (France); Institute of Scientific Instruments of the CAS, Kralovopolska 147, 612 64 Brno (Czech Republic); Alexandre, Christophe [Centre d’Études et de Recherche en Informatique et Communications (CEDRIC), Cnam, 292 rue St-Martin, 75003 Paris (France)

    2016-07-15

    We have developed an optical Absolute Distance Meter (ADM) based on the measurement of the phase accumulated by a Radio Frequency wave during its propagation in the air by a laser beam. In this article, the ADM principle will be described and the main results will be presented. In particular, we will emphasize how the choice of an appropriate photodetector can significantly improve the telemeter performances by minimizing the amplitude to phase conversion. Our prototype, tested in the field, has proven its efficiency with a resolution better than 15 μm for a measurement time of 10 ms and distances up to 1.2 km.

  16. Inferring DOC export mechanisms from high-frequency, instream UV-VIS concentration measurements

    Science.gov (United States)

    Oosterwoud, Marieke; Musolff, Andreas; Keller, Toralf; Fleckenstein, Jan

    2015-04-01

    The flux of soil-derived dissolved organic carbon (DOC) is a significant term in terrestrial carbon budgets and, as a result, a dominant link between terrestrial and aquatic ecosystems. Concentrations of dissolved organic carbon in streams and rivers have been increasing in many parts of the world. Providers of drinking water from surface water reservoirs are increasingly facing problems as elevated DOC concentrations cause higher costs for removal and potentially to toxic by-products during chlorination. Mitigating these problems requires a mechanistic understanding of the controls and dynamics of DOC export from catchments. High frequency measurements using UV-vis absorbance as a proxy for DOC concentrations allow for improved evaluation of DOC concentration-discharge relationships in catchments. In addition, several UV-vis absorbance proxies (both single and multiple wavelength) can be used as an indicator of DOC quality. These relationships allow quantification of net DOC export, and may additionally provide new insights into the mechanisms that control DOC export dynamics. We aimed to evaluate the response and interaction of DOC concentrations and quality between a riparian zone soil and stream under different hydrological conditions. UV-vis sensors were installed in both the riparian soil and stream of two headwater catchments, the Hassel and Rappbode, in the Harz Mountains in Germany. The two headwater catchments are approximately equal in size, however, differ in their land-use. The Hassel catchment is dominated by agricultural land-use, whereas the Rappbode catchment is mainly forested. The DOC concentration-discharge relationships show intricate hysteretic behavior, which differs between locations and shifts in time. The rich data-set will allow for a characterization of space and time patterns of DOC export as well as changes in its quality, providing valuable new insights into the hydrologic mechanisms that govern the delivery of DOC to streams.

  17. Readout for intersatellite laser interferometry: Measuring low frequency phase fluctuations of high-frequency signals with microradian precision

    DEFF Research Database (Denmark)

    Gerberding, Oliver; Diekmann, Christian; Kullmann, Joachim

    2015-01-01

    Precision phase readout of optical beat note signals is one of the core techniques required for inter-satellite laser interferometry. Future space based gravitational wave detectors like eLISA require such a readout over a wide range of MHz frequencies, due to orbit induced Doppler shifts...

  18. High frequency microphone measurements for transition detection on airfoils. NACA-0015 appendix report

    DEFF Research Database (Denmark)

    Døssing, Mads

    Time series of pressure fluctuations has been obtained using high frequency microphones distributed over the surface of airfoils undergoing wind tunnel tests in the LM Windtunnel, owned by ’LM Glasfiber’, Denmark. The present report describes the dataanalysis, with special attention given...... to transition detection. It is argued that the transition point can be detected by observing the increase in the mean of the Fourier spectre and that thismethod is very stable froma numerical point of view. Other important issues are also discussed, e.g. the variation of pressure standard deviations (sound...

  19. Preference and intake frequency of high sodium foods and dishes and their correlations with anthropometric measurements among Malaysian subjects.

    Science.gov (United States)

    Choong, Stella Sinn-Yee; Balan, Sumitha Nair; Chua, Leong-Siong; Say, Yee-How

    2012-06-01

    This study investigated the preference and intake frequency of a list of 15 commonly available high sodium Malaysian foods/dishes, discretionary salt use, and their possible association with demographics, blood pressures and anthropometric measurements among 300 Malaysian university students (114 males, 186 females; 259 ethnic Chinese, 41 Indians; 220 lean, 80 overweight). French fries and instant soup noodle were found to be the most preferred and most frequently consumed salty food, respectively, while salted fish was least preferred and least frequently consumed. Males had a significantly higher intake frequency of at least 6 of the salty foods, but the preference of most salty foods was not significantly different between genders. Ethnic Chinese significantly preferred more and took more frequently traditional and conventional Malaysian foods like asam laksa (a Malaysian salty-sour-spicy noodle in fish stock), salted biscuits and salted vegetable, while Indians have more affinity and frequency towards eating salty Western foods. Body Mass Index was significantly negatively correlated with the intake frequency of canned/packet soup and salted fish while waist circumference was significantly positively correlated with the preference of instant noodle. Also, an increased preference of potato chips and intake frequency of salted biscuits seemed to lead to a decreased WHR. Other than these, all the other overweight/obesity indicators did not seem to fully correlate with the salty food preference and intake frequency. Nevertheless, the preference and intake frequency of asam laksa seemed to be significant negative predictors for blood pressures. Finally, increased preference and intake frequency of high sodium shrimp paste (belacan)-based foods like asam laksa and belacan fried rice seemed to discourage discretionary salt use. In conclusion, the preference and intake frequency of the high sodium belacan-based dish asam laksa seems to be a good predictor for ethnic

  20. Comparison between high-frequency ultrasonography and histological assessment reveals weak correlation for measurements of scar tissue thickness.

    Science.gov (United States)

    Agabalyan, Natacha A; Su, Samuel; Sinha, Sarthak; Gabriel, Vincent

    2017-05-01

    Current methods for evaluating scar tissue volume following burns have shortcomings. The Vancouver Burn Scar scale is subjective, leading to a high variability in assessment. Although histological assessment via punch biopsy can discriminate between the different layers of skin, such an approach is invasive, inefficient, and detrimental to patient experience and wound healing. This study investigates the accuracy of high-frequency ultrasonography, a non-invasive alternative to histology, for measuring dermal and epidermal thickness in scar tissue. Scar thicknesses of 10 patients following burns were assessed using a 2-D high-frequency ultrasound probe. The scars were then biopsied using a circular 4mm punch biopsy for histological assessment. Dermal, epidermal, and total thickness of the scar tissue was measured using ultrasound and histology, and correlations between the two measurements were calculated. There was not a strong correlation between ultrasound measurement and histological analysis for epidermal, dermal, and total thickness (Spearman's rank correlation of -0.1223, -0.6242, and -0.6242) of scar tissue. Measurements of scar thickness using high-frequency ultrasonography did not recapitulate the in vivo dermal, epidermal and total thickness. Based on these findings, strategies for further optimization of 2-D ultrasonography is discussed before clinical and research use. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  1. A digital instantaneous frequency measurement technique utilising high speed analogue to digital converters and field programmable gate arrays

    CSIR Research Space (South Africa)

    Herselman, PLR

    2007-09-01

    Full Text Available In modern information and sensor systems, the timely estimation of the carrier frequency of received signals is of critical importance. This paper presents a digital instantaneous frequency measurement (DIFM) technique, which can measure the carrier...

  2. High Frequency Field Measurements of an Undular Bore Using a 2D LiDAR Scanner

    Directory of Open Access Journals (Sweden)

    Kévin Martins

    2017-05-01

    Full Text Available The secondary wave field associated with undular tidal bores (known as whelps has been barely studied in field conditions: the wave field can be strongly non-hydrostatic, and the turbidity is generally high. In situ measurements based on pressure or acoustic signals can therefore be limited or inadequate. The intermittent nature of this process in the field and the complications encountered in the downscaling to laboratory conditions also render its study difficult. Here, we present a new methodology based on LiDAR technology to provide high spatial and temporal resolution measurements of the free surface of an undular tidal bore. A wave-by-wave analysis is performed on the whelps, and comparisons between LiDAR, acoustic and pressure-derived measurements are used to quantify the non-hydrostatic nature of this phenomenon. A correction based on linear wave theory applied on individual wave properties improves the results from the pressure transducer (Root mean square error, R M S E of 0 . 19 m against 0 . 38 m; however, more robust data is obtained from an upwards-looking acoustic sensor despite high turbidity during the passage of the whelps ( R M S E of 0 . 05 m. Finally, the LiDAR scanner provides the unique possibility to study the wave geometry: the distribution of measured wave height, period, celerity, steepness and wavelength are presented. It is found that the highest wave from the whelps can be steeper than the bore front, explaining why breaking events are sometimes observed in the secondary wave field of undular tidal bores.

  3. High frequency electromagnetic dosimetry

    CERN Document Server

    Sánchez-Hernández, David A

    2009-01-01

    Along with the growth of RF and microwave technology applications, there is a mounting concern about the possible adverse effects over human health from electromagnetic radiation. Addressing this issue and putting it into perspective, this groundbreaking resource provides critical details on the latest advances in high frequency electromagnetic dosimetry.

  4. Adaptation of a High Frequency Ultrasonic Transducer to the Measurement of Water Temperature in a Nuclear Reactor

    Science.gov (United States)

    Zaz, G.; Calzavara, Y.; Le Clézio, E.; Despaux, G.

    Most high flux reactors possess for research purposes fuel elements composed of plates. Their relative distance is a crucial parameter, particularly concerning the irradiation history. For the High Flux Reactor (RHF) of the Institute Laue-Langevin (ILL), the measurement of this distance with a microscopic resolution becomes extremely challenging. To address this issue, a specific ultrasonic transducer, presented in a first paper, has been designed and manufactured to be inserted into the 1.8 mm width channel existing between curved fuel plates. It was set on a blade yielding a total device thickness of 1 mm. To achieve the expected resolution, the system is excited with frequencies up to 70 MHz and integrated into a set of high frequency acquisition instruments. Thanks to a specific signal processing, this device allows the distance measurement through the evaluation of the ultrasonic wave time of fight. One of the crucial points is then the evaluation of the local water temperature inside the water channel. To obtain a precise estimation of this parameter, the ultrasonic sensor is used as a thermometer thanks to the analysis of the spectral components of the acoustic signal propagating inside the sensor multilayered structure. The feasibility of distance measurement was proved during the December 2013 experiment in the RHF fuel element of the ILL. Some of the results will be presented as well as some experimental constraints identified to improve the accuracy of the measurement in future works.

  5. Comparative Analysis of Selected High Frequency Words Found in Commercial Spelling Series and Misspelled in Students' Writing to a Standard Measure of Word Frequency.

    Science.gov (United States)

    Hagerty, Patricia Jo

    A major purpose of this study was to determine whether a selected number of current, commercially prepared spelling series used high frequency words for their word lists. A second purpose was to determine whether students misspelled high frequency words in their writing. Eleven commercially prepared spelling series were selected according to the…

  6. A multivariate correlation analysis of high-frequency bottom backscattering strength measurements with geotechnical parameters

    NARCIS (Netherlands)

    Simons, D.G.; Snellen, M.; Ainslie, M.A.

    2007-01-01

    Sound backscattered from the seabed has been measured in a 10 × 10-nmi2 region of the North Sea, characterized by a variety of bottom types, including mud, sand, and gravel. The backscattering strength measurements are made by a forward-looking sonar, operating at 100 kHz and tilted at an angle of

  7. Brahan Project High Frequency Radar Ocean Measurements: Currents, Winds, Waves and Their Interactions

    Directory of Open Access Journals (Sweden)

    Belinda Lipa

    2014-12-01

    Full Text Available We describe radar measurements of waves, currents and winds made on the coast of northern Scotland during two 2013/14 winter storms, giving methods, results and interpretation. Wave parameters (height, period, direction and short-wave/wind direction were derived and compared with measurements made by a neighboring buoy and local weather stations. Wind direction and current velocity maps were produced and the interactions of winds and currents discussed. Significant oscillations in wave parameters were observed, which appear to be due to forcing by tidal current velocity variations. The oscillations in waveheight are explained using hydrodynamic analysis and derived amplitudes are compared with radar measurements.

  8. Long-term, high frequency in situ measurements of intertidal mussel bed temperatures using biomimetic sensors.

    Science.gov (United States)

    Helmuth, Brian; Choi, Francis; Matzelle, Allison; Torossian, Jessica L; Morello, Scott L; Mislan, K A S; Yamane, Lauren; Strickland, Denise; Szathmary, P Lauren; Gilman, Sarah E; Tockstein, Alyson; Hilbish, Thomas J; Burrows, Michael T; Power, Anne Marie; Gosling, Elizabeth; Mieszkowska, Nova; Harley, Christopher D G; Nishizaki, Michael; Carrington, Emily; Menge, Bruce; Petes, Laura; Foley, Melissa M; Johnson, Angela; Poole, Megan; Noble, Mae M; Richmond, Erin L; Robart, Matt; Robinson, Jonathan; Sapp, Jerod; Sones, Jackie; Broitman, Bernardo R; Denny, Mark W; Mach, Katharine J; Miller, Luke P; O'Donnell, Michael; Ross, Philip; Hofmann, Gretchen E; Zippay, Mackenzie; Blanchette, Carol; Macfarlan, J A; Carpizo-Ituarte, Eugenio; Ruttenberg, Benjamin; Peña Mejía, Carlos E; McQuaid, Christopher D; Lathlean, Justin; Monaco, Cristián J; Nicastro, Katy R; Zardi, Gerardo

    2016-10-11

    At a proximal level, the physiological impacts of global climate change on ectothermic organisms are manifest as changes in body temperatures. Especially for plants and animals exposed to direct solar radiation, body temperatures can be substantially different from air temperatures. We deployed biomimetic sensors that approximate the thermal characteristics of intertidal mussels at 71 sites worldwide, from 1998-present. Loggers recorded temperatures at 10-30 min intervals nearly continuously at multiple intertidal elevations. Comparisons against direct measurements of mussel tissue temperature indicated errors of ~2.0-2.5 °C, during daily fluctuations that often exceeded 15°-20 °C. Geographic patterns in thermal stress based on biomimetic logger measurements were generally far more complex than anticipated based only on 'habitat-level' measurements of air or sea surface temperature. This unique data set provides an opportunity to link physiological measurements with spatially- and temporally-explicit field observations of body temperature.

  9. Mode-resolved frequency comb interferometry for high-accuracy long distance measurement

    National Research Council Canada - National Science Library

    Van den Berg, S.A; Van Eldik, S; Bhattacharya, N

    2015-01-01

    .... From the spectrally resolved output of a Michelson interferometer a distance is derived. The presented measurement method combines spectral interferometry, white light interferometry and multi-wavelength interferometry in a single scheme...

  10. Long-term, high frequency in situ measurements of intertidal mussel bed temperatures using biomimetic sensors

    Science.gov (United States)

    Helmuth, Brian; Choi, Francis; Matzelle, Allison; Torossian, Jessica L.; Morello, Scott L.; Mislan, K. A. S.; Yamane, Lauren; Strickland, Denise; Szathmary, P. Lauren; Gilman, Sarah E.; Tockstein, Alyson; Hilbish, Thomas J.; Burrows, Michael T.; Power, Anne Marie; Gosling, Elizabeth; Mieszkowska, Nova; Harley, Christopher D. G.; Nishizaki, Michael; Carrington, Emily; Menge, Bruce; Petes, Laura; Foley, Melissa M.; Johnson, Angela; Poole, Megan; Noble, Mae M.; Richmond, Erin L.; Robart, Matt; Robinson, Jonathan; Sapp, Jerod; Sones, Jackie; Broitman, Bernardo R.; Denny, Mark W.; Mach, Katharine J.; Miller, Luke P.; O'Donnell, Michael; Ross, Philip; Hofmann, Gretchen E.; Zippay, Mackenzie; Blanchette, Carol; Macfarlan, J. A.; Carpizo-Ituarte, Eugenio; Ruttenberg, Benjamin; Peña Mejía, Carlos E.; McQuaid, Christopher D.; Lathlean, Justin; Monaco, Cristián J.; Nicastro, Katy R.; Zardi, Gerardo

    2016-10-01

    At a proximal level, the physiological impacts of global climate change on ectothermic organisms are manifest as changes in body temperatures. Especially for plants and animals exposed to direct solar radiation, body temperatures can be substantially different from air temperatures. We deployed biomimetic sensors that approximate the thermal characteristics of intertidal mussels at 71 sites worldwide, from 1998-present. Loggers recorded temperatures at 10-30 min intervals nearly continuously at multiple intertidal elevations. Comparisons against direct measurements of mussel tissue temperature indicated errors of ~2.0-2.5 °C, during daily fluctuations that often exceeded 15°-20 °C. Geographic patterns in thermal stress based on biomimetic logger measurements were generally far more complex than anticipated based only on ‘habitat-level’ measurements of air or sea surface temperature. This unique data set provides an opportunity to link physiological measurements with spatially- and temporally-explicit field observations of body temperature.

  11. Brahan Project High Frequency Radar Ocean Measurements: Currents, Winds, Waves and Their Interactions

    OpenAIRE

    Belinda Lipa; Donald Barrick; Andres Alonso-Martirena; Maria Fernandes; Maria Inmaculada Ferrer; Bruce Nyden

    2014-01-01

    We describe radar measurements of waves, currents and winds made on the coast of northern Scotland during two 2013/14 winter storms, giving methods, results and interpretation. Wave parameters (height, period, direction and short-wave/wind direction) were derived and compared with measurements made by a neighboring buoy and local weather stations. Wind direction and current velocity maps were produced and the interactions of winds and currents discussed. Significant oscillations in wave param...

  12. Aerodynamic noise characterization of a full-scale wind turbine through high-frequency surface pressure measurements

    DEFF Research Database (Denmark)

    Bertagnolio, Franck; Aagaard Madsen, Helge; Bak, Christian

    2015-01-01

    wind turbine with a 80 m diameter rotor as well as measurements of an airfoil section tested in a wind tunnel. The turbine was extensively equipped in order to monitor the local inflow onto the rotating blades. Further a section of the 38 m long blade was instrumented with 50 microphones flush...... in a wind tunnel on a copy of the blade section of the full scale blade. Computational Fluid Dynamics calculations were conducted to investigate the influence of the inflow conditions on the airfoil and blade sections aerodynamics and aeroacoustics. Comparisons between measurement data and model results......The aim of this work is to investigate and characterize the high-frequency surface pressure fluctuations on a full-scale wind turbine blade and in particular the influence of the atmospheric turbulence. As these fluctuations are highly correlated to the sources of both turbulent inflow noise...

  13. Measuring and Forecasting Financial Market Volatility using High-Frequency Data

    NARCIS (Netherlands)

    K. Bannouh (Karim)

    2013-01-01

    textabstractThis dissertation consists of three studies on the use of intraday asset price data for accurate measurement and forecasting of financial market volatility. Chapter 2 proposes a refined heuristic bias-correction for the two time scales realized range-based volatility estimator in the

  14. Long-term, high frequency in situ measurements of intertidal mussel bed temperatures using biomimetic sensors

    Science.gov (United States)

    Helmuth, Brian; Choi, Francis; Matzelle, Allison; Torossian, Jessica L.; Morello, Scott L.; Mislan, K.A.S.; Yamane, Lauren; Strickland, Denise; Szathmary, P. Lauren; Gilman, Sarah E.; Tockstein, Alyson; Hilbish, Thomas J.; Burrows, Michael T.; Power, Anne Marie; Gosling, Elizabeth; Mieszkowska, Nova; Harley, Christopher D.G.; Nishizaki, Michael; Carrington, Emily; Menge, Bruce; Petes, Laura; Foley, Melissa M.; Johnson, Angela; Poole, Megan; Noble, Mae M.; Richmond, Erin L.; Robart, Matt; Robinson, Jonathan; Sapp, Jerod; Sones, Jackie; Broitman, Bernardo R.; Denny, Mark W.; Mach, Katharine J.; Miller, Luke P.; O’Donnell, Michael; Ross, Philip; Hofmann, Gretchen E.; Zippay, Mackenzie; Blanchette, Carol; Macfarlan, J.A.; Carpizo-Ituarte, Eugenio; Ruttenberg, Benjamin; Peña Mejía, Carlos E.; McQuaid, Christopher D.; Lathlean, Justin; Monaco, Cristián J.; Nicastro, Katy R.; Zardi, Gerardo

    2016-01-01

    At a proximal level, the physiological impacts of global climate change on ectothermic organisms are manifest as changes in body temperatures. Especially for plants and animals exposed to direct solar radiation, body temperatures can be substantially different from air temperatures. We deployed biomimetic sensors that approximate the thermal characteristics of intertidal mussels at 71 sites worldwide, from 1998-present. Loggers recorded temperatures at 10–30 min intervals nearly continuously at multiple intertidal elevations. Comparisons against direct measurements of mussel tissue temperature indicated errors of ~2.0–2.5 °C, during daily fluctuations that often exceeded 15°–20 °C. Geographic patterns in thermal stress based on biomimetic logger measurements were generally far more complex than anticipated based only on ‘habitat-level’ measurements of air or sea surface temperature. This unique data set provides an opportunity to link physiological measurements with spatially- and temporally-explicit field observations of body temperature. PMID:27727238

  15. High frequency nanotube oscillator

    Science.gov (United States)

    Peng, Haibing [Houston, TX; Zettl, Alexander K [Kensington, TX

    2012-02-21

    A tunable nanostructure such as a nanotube is used to make an electromechanical oscillator. The mechanically oscillating nanotube can be provided with inertial clamps in the form of metal beads. The metal beads serve to clamp the nanotube so that the fundamental resonance frequency is in the microwave range, i.e., greater than at least 1 GHz, and up to 4 GHz and beyond. An electric current can be run through the nanotube to cause the metal beads to move along the nanotube and changing the length of the intervening nanotube segments. The oscillator can operate at ambient temperature and in air without significant loss of resonance quality. The nanotube is can be fabricated in a semiconductor style process and the device can be provided with source, drain, and gate electrodes, which may be connected to appropriate circuitry for driving and measuring the oscillation. Novel driving and measuring circuits are also disclosed.

  16. High-Frequency, Automated Measurements of CO2, N2O and CH4 from Forested Soils

    Science.gov (United States)

    Savage, K. E.; Davidson, E. A.; Phillips, R. L.

    2011-12-01

    Carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O) are the most important anthropogenic greenhouse gases. Soils are the dominant natural source of N2O, and fertilized agricultural soils are a major source of increasing anthropogenic N2O. Anthropogenic sources of CH4 include rice cultivation, while wetlands are a significant natural source, and upland soils are a natural CH4 sink. While most anthropogenic CO2 is derived from fossil fuel combustion, a significant fraction is from land use change, including a portion from loss of soil carbon. Soils play a central role as sources and sinks of the three most important anthropogenic greenhouse gases of the 21st century, CO2, CH4, and N2O. Variation in soil moisture can be very dynamic, and it is one of the dominant factors controlling soil aeration, and hence the balance between aerobic (CO2 producing) and anaerobic (CH4 producing) respiration. The production and consumption of N2O is also highly dependent on spatial and temporal variation in soil moisture. Although technologies for high frequency, precise measurements of CO2 have been available for years, methods for measuring soil fluxes of CH4 and N2O at high temporal frequency have been hampered by lack of appropriate technology for in situ real-time measurements. We utilized a previously developed automated chamber system for measuring CO2 efflux (Licor 6252 IRGA) from soils, and configured it to run in-line with a new model quantum cascade laser (QCL) system which measures N2O and CH4 (Aerodyne model QC-TILDAS-CS). The QCL is thermoelectrically cooled and uses a 76-meter path length, 0.5 liter volume, and multiple pass absorption cell for sampling. The QCL sampling frequency is 10Hz, and its range is 0.3 to 3000 ppb for N2O with a sensitivity of 0.3 ppb, and 0.5 to 5000 ppb for CH4 with a sensitivity of 0.5 ppb. Six sampling chambers, with corresponding soil water content and soil temperature sensors, were deployed at the Howland Forest ME, in an upland

  17. Differentiating epileptic from non-epileptic high frequency intracerebral EEG signals with measures of wavelet entropy.

    Science.gov (United States)

    Mooij, Anne H; Frauscher, Birgit; Amiri, Mina; Otte, Willem M; Gotman, Jean

    2016-12-01

    To assess whether there is a difference in the background activity in the ripple band (80-200Hz) between epileptic and non-epileptic channels, and to assess whether this difference is sufficient for their reliable separation. We calculated mean and standard deviation of wavelet entropy in 303 non-epileptic and 334 epileptic channels from 50 patients with intracerebral depth electrodes and used these measures as predictors in a multivariable logistic regression model. We assessed sensitivity, positive predictive value (PPV) and negative predictive value (NPV) based on a probability threshold corresponding to 90% specificity. The probability of a channel being epileptic increased with higher mean (p=0.004) and particularly with higher standard deviation (pentropy is likely to be epileptic; with a threshold corresponding to 90% specificity our model can reliably select a subset of epileptic channels. Most studies have concentrated on brief ripple events. We showed that background activity in the ripple band also has some ability to discriminate epileptic channels. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  18. High Accuracy Microwave Frequency Measurement Based on Single-Drive Dual-Parallel Mach-Zehnder Modulator

    DEFF Research Database (Denmark)

    Zhao, Ying; Deng, Lei; Pang, Xiaodan

    2011-01-01

    A novel approach for broadband microwave frequency measurement based on bias manipulation of a dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. A 10-3 relative error verifies a significant accuracy improvement by this method....

  19. Effect of closed endotracheal suction in high-frequency ventilated premature infants measured with electrical impedance tomography

    NARCIS (Netherlands)

    van Veenendaal, M.B.; Miedema, M.; de Jongh, F.H.C.; van der Lee, J.H.; Frerichs, I.; van Kaam, A.H.

    2009-01-01

    Objective: To determine the global and regional changes in lung volume during and after closed endotracheal tube (ETT) suction in high-frequency ventilated preterm infants with respiratory distress syndrome (RDS). Design: Prospective observational clinical study. Setting: Neonatal intensive care

  20. Non-invasive measure of respiratory mechanics and conventional respiratory parameters in conscious large animals by high frequency Airwave Oscillometry.

    Science.gov (United States)

    Bassett, Leanne; Troncy, Eric; Robichaud, Annette; Schuessler, Thomas F; Pouliot, Mylène; Ascah, Alexis; Authier, Simon

    2014-01-01

    A number of drugs in clinical trials are discontinued due to potentially life-threatening airway obstruction. As some drugs may not cause changes in core battery parameters such as tidal volume (Vt), respiratory rate (RR) or minute ventilation (MV), including measurements of respiratory mechanics in safety pharmacology studies represents an opportunity for design refinement. The present study aimed to test a novel non-invasive methodology to concomitantly measure respiratory system resistance (Rrs) and conventional respiratory parameters (Vt, RR, MV) in conscious Beagle dogs and cynomolgus monkeys. An Airwave Oscillometry system (tremoFlo; THORASYS Inc., Montreal, Canada) was used to concomitantly assess Rrs and conventional respiratory parameters before and after intravenous treatment with a bronchoactive agent. Respiratory mechanics measurements were performed by applying a short (i.e. 16s) single high frequency (19Hz) waveform at the subject's airway opening via a face mask. During measurements, pressure and flow signals were recorded. After collection of baseline measurements, methacholine was administered intravenously to Beagle dogs (n=6) and cynomolgus monkeys (n=4) at 8 and 68μg/kg, respectively. In dogs, methacholine induced significant increases in Vt, RR and MV while in monkeys, it only augmented RR. A significant increase in Rrs was observed after methacholine administration in both species with mean percentage peak increases from baseline of 88 (53)% for dogs and 28 (16)% for cynomolgus monkeys. Airwave Oscillometry appears to be a promising non-invasive methodology to enable respiratory mechanics measurements in conscious large animals, a valuable refinement in respiratory safety pharmacology. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Calibrating high-precision Faraday rotation measurements for LOFAR and the next generation of low-frequency radio telescopes

    NARCIS (Netherlands)

    Sotomayor-Beltran, C.; et al., [Unknown; Hessels, J.W.T.; Alexov, A.; van Leeuwen, J.; Markoff, S.; Wijers, R.A.M.J.; Wise, M.W.

    2013-01-01

    Faraday rotation measurements using the current and next generation of low-frequency radio telescopes will provide a powerful probe of astronomical magnetic fields. However, achieving the full potential of these measurements requires accurate removal of the time-variable ionospheric Faraday rotation

  2. Hourly surface currents measured by high frequency Wellen radars off western Oahu, Hawaii, from September 2002 to May 2003 (NODC Accession 0013113)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A pair of High Frequency Wellen radars (WERA) shore-based at southwest Oahu (Ko'Olina) and northwest Oahu (Kaena), Hawaii measured surface currents over a nine-month...

  3. Hourly surface currents measured by High Frequency (HF) Wellen radars (WERA) off western Oahu, Hawaii, from September 2002 to May 2003 (NODC Accession 0013113)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A pair of High Frequency Wellen radars (WERA) shore-based at southwest Oahu (Ko'Olina) and northwest Oahu (Kaena), Hawaii measured surface currents over a nine-month...

  4. Measurements of attenuation coefficient for evaluating the hardness of a cataract lens by a high-frequency ultrasonic needle transducer

    Science.gov (United States)

    Chen, Ruimin; Tsui, Po-Hsiang; Zhou, Qifa; Humayun, Mark S; Shung, K Kirk

    2010-01-01

    A cataract is a clouding of the lens in the eye that affects vision. Phacoemulsification is the mostly common surgical method for treating cataracts, and determining that the optimal phacoemulsification energy is dependent on measuring the hardness of the lens. This study explored the use of an ultrasound needle transducer for invasive measurements of ultrasound attenuation coefficient to evaluate the hardness of the cataract lens. A 47 MHz high-frequency needle transducer with a diameter of 0.9 mm was fabricated by a polarized PMN-33%PT single crystal in the present study. The attenuation coefficients at different stages of an artificial porcine cataract lens were measured using the spectral shift approach. The hardness of the cataract lens was also evaluated by mechanical measurement of its elastic properties. The results demonstrated that the ultrasonic attenuation coefficient was increased from 0.048 ± 0.02 to 0.520 ± 0.06 dB mm−1 MHz−1 corresponding to an increase in Young’s modulus from 6 ± 0.4 to 96 ± 6.2 kPa as the cataract further developed. In order to evaluate the feasibility of combining needle transducer and phacoemulsification probe for real-time measurement during cataract surgery, the needle transducer was mounted on the phacoemulsification probe for a vibration test. The results indicated that there was no apparent damage to the tip of the needle transducer and the pulse–echo test showed that a good performance in sensitivity was maintained after the vibration test. PMID:19759408

  5. Measurements of attenuation coefficient for evaluating the hardness of a cataract lens by a high-frequency ultrasonic needle transducer

    Energy Technology Data Exchange (ETDEWEB)

    Huang, C.-C. [Department of Electronic Engineering, Fu Jen Catholic University, Taipei 24205, Taiwan (China); Chen Ruimin; Zhou Qifa; Shung, K Kirk [NIH Resource on Medical Ultrasonic Transducer Technology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089 (United States); Tsui, P.-H. [Division of Mechanics, Research Center for Applied Sciences, Academia Sinica, Taipei 11529, Taiwan (China); Humayun, Mark S [Doheny Retina Institute, Doheny Eye Institute, Department of Ophthalmology, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033 (United States)], E-mail: j648816n@ms23.hinet.net

    2009-10-07

    A cataract is a clouding of the lens in the eye that affects vision. Phacoemulsification is the mostly common surgical method for treating cataracts, and determining that the optimal phacoemulsification energy is dependent on measuring the hardness of the lens. This study explored the use of an ultrasound needle transducer for invasive measurements of ultrasound attenuation coefficient to evaluate the hardness of the cataract lens. A 47 MHz high-frequency needle transducer with a diameter of 0.9 mm was fabricated by a polarized PMN-33%PT single crystal in the present study. The attenuation coefficients at different stages of an artificial porcine cataract lens were measured using the spectral shift approach. The hardness of the cataract lens was also evaluated by mechanical measurement of its elastic properties. The results demonstrated that the ultrasonic attenuation coefficient was increased from 0.048 {+-} 0.02 to 0.520 {+-} 0.06 dB mm{sup -1} MHz{sup -1} corresponding to an increase in Young's modulus from 6 {+-} 0.4 to 96 {+-} 6.2 kPa as the cataract further developed. In order to evaluate the feasibility of combining needle transducer and phacoemulsification probe for real-time measurement during cataract surgery, the needle transducer was mounted on the phacoemulsification probe for a vibration test. The results indicated that there was no apparent damage to the tip of the needle transducer and the pulse-echo test showed that a good performance in sensitivity was maintained after the vibration test.

  6. An Isotope Dilution Method for High-frequency Measurements of Dissolved Inorganic Carbon concentration in the Surface Ocean

    Science.gov (United States)

    Huang, K.; Bender, M. L.; Wanninkhof, R. H.; Cassar, N.

    2013-12-01

    Dissolved inorganic carbon (DIC) is one of the most important species in the ocean carbon system. An autonomous system using isotope dilution as its core method has been developed to obtain high-frequency measurements of dissolved inorganic carbon (DIC) concentrations in the surface ocean. This system accurately mixes a seawater sample and a 13C-labeled sodium bicarbonate solution (spike). The mixed solution is then acidified and sent through a gas permeable membrane contactor. CO2 derived from DIC in the mixture is extracted by a CO2-free gas stream, and is sent to a cavity ring-down spectrometer to analyze its 13C/12C ratio. [DIC] of the seawater can then be derived from the measured 13C/12C, the known mixing ratio and the [DI13C] of the spike. The method has been tested under a wide [DIC] range (1800-2800 μmol/kg) in the laboratory. It has also been deployed on a cruise that surveyed ocean waters to the south of Florida. At a sampling resolution of 4 minutes (15 samples per hour), the relative standard deviation of DIC determined from the laboratory tests and the field deployment is ×0.07% and ×0.09%, respectively. The accuracy of the method is better than 0.1% except where [DIC] varies faster than 5 μmol/kg per minute. Based on the laboratory and field evaluations, we conclude that this method can provide accurate underway [DIC] measurements at high resolution in most oceanic regions. Schematic illustration of the work flow.

  7. A 15 year record of high-frequency, in situ measurements of hydrogen at Mace Head, Ireland

    Directory of Open Access Journals (Sweden)

    A. Grant

    2010-02-01

    Full Text Available Continuous high-frequency measurements of atmospheric molecular hydrogen have been made at Mace Head atmospheric research station on the west coast of Ireland from March 1994 to December 2008. The presented data provides information on long term trends and seasonal cycles of hydrogen in background northern hemispheric air. Individual measurements have been sorted using a Lagrangian dispersion model to separate clean background air from regionally polluted European air masses and those transported from southerly latitudes. No significant trend was observed in background northern hemispheric air over the 15 year record, elevations in yearly means were accounted for from large scale biomass burning events. Seasonal cycles show the expected pattern with maxima in spring and minima in late autumn. The mean hydrogen mole fraction in baseline northern hemispheric air was found to be 500.1 ppb. Air transported from southerly latitudes showed an elevation from baseline mean of 11.0 ppb, reflecting both the latitudinal gradient of hydrogen, with higher concentrations in the Southern Hemisphere, and the photochemical source of hydrogen from low northern latitudes. European polluted air masses arriving at Mace Head showed mean elevation of 5.3 ppb from baseline air masses, reflecting hydrogen's source from primary emissions like fossil fuel combustion. Forward modelling of transport of hydrogen to Mace Head suggests that the ratio of hydrogen to carbon monoxide in primary emissions is considerably less in non-traffic sources than traffic sources.

  8. Measurement and Analysis of Partial Discharge using an Ultra-High Frequency Sensor for Gas Insulated Structures

    Directory of Open Access Journals (Sweden)

    Wang Guoming

    2017-09-01

    Full Text Available Although the gas insulated structures have a high degree of reliability, the unavoidable defects are primary reason of their failures. Partial discharge (PD has been regarded as an effective indication for condition monitoring and diagnosis of gas insulated switchgears (GISs to ensure their reliable and stable operation. Among various PD detection methods, the ultra-high frequency (UHF technique has the advantages of on-line motoring and defect classification. In this paper, there are presented 7 types of artificial electrode systems fabricated for simulation of real insulation defects in gas insulated structures. A real-time measurement system was developed to acquire defect patterns in a form of phase-resolve partial discharge (PRPD intensity graph, using a UHF sensor. Further, the discharge distribution and statistical characteristics were extracted for defect identification using a neural network algorithm. In addition, a conversion experiment was proposed by detecting the PD pulse simultaneously using a non-induction resistor and a UHF sensor. A relationship between the magnitude of UHF signal and the amplitude of apparent charge was established, which was used for evaluation of PD using the UHF sensor.

  9. Silicon Photoelectrode Thermodynamics and Hydrogen Evolution Kinetics Measured by Intensity-Modulated High-Frequency Resistivity Impedance Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Neale, Nathan R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Anderson, Nicholas C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Christensen, Steven T [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Van De Lagemaat, Jao [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Pekarek, Ryan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Carroll, Gerard M. [Formerly NREL

    2017-10-13

    We present an impedance technique based on light intensity-modulated high-frequency resistivity (IMHFR) that provides a new way to elucidate both the thermodynamics and kinetics in complex semiconductor photoelectrodes. We apply IMHFR to probe electrode interfacial energetics on oxide-modified semiconductor surfaces frequently used to improve the stability and efficiency of photoelectrochemical water splitting systems. Combined with current density-voltage measurements, the technique quantifies the overpotential for proton reduction relative to its thermodynamic potential in Si photocathodes coated with three oxides (SiOx, TiO2, and Al2O3) and a Pt catalyst. In pH 7 electrolyte, the flatband potentials of TiO2- and Al2O3-coated Si electrodes are negative relative to samples with native SiOx, indicating that SiOx is a better protective layer against oxidative electrochemical corrosion than ALD-deposited crystalline TiO2 or Al2O3. Adding a Pt catalyst to SiOx/Si minimizes proton reduction overpotential losses but at the expense of a reduction in available energy characterized by a more negative flatband potential relative to catalyst-free SiOx/Si.

  10. Automatic real-time control of suspended sediment based upon high frequency in situ measurements of nephelometric turbidity

    Science.gov (United States)

    Jack Lewis; Rand Eads

    1998-01-01

    Abstract - For estimating suspended sediment concentration (SSC) in rivers, turbidity is potentially a much better predictor than water discharge. Since about 1990, it has been feasible to automatically collect high frequency turbidity data at remote sites using battery-powered turbidity probes that are properly mounted in the river or stream. With sensors calibrated...

  11. Effect of closed endotracheal suction in high-frequency ventilated premature infants measured with electrical impedance tomography

    NARCIS (Netherlands)

    van Veenendaal, Mariëtte B.; Miedema, Martijn; de Jongh, Frans H. C.; van der Lee, Johanna H.; Frerichs, Inez; van Kaam, Anton H.

    2009-01-01

    To determine the global and regional changes in lung volume during and after closed endotracheal tube (ETT) suction in high-frequency ventilated preterm infants with respiratory distress syndrome (RDS). Prospective observational clinical study. Neonatal intensive care unit. Eleven non-muscle relaxed

  12. New insights into nitrate dynamics in a karst groundwater system gained from in situ high-frequency optical sensor measurements

    Science.gov (United States)

    Opsahl, S. P.; Musgrove, M.; Slattery, R. N.

    2017-03-01

    Understanding nitrate dynamics in groundwater systems as a function of climatic conditions, especially during contrasting patterns of drought and wet cycles, is limited by a lack of temporal and spatial data. Nitrate sensors have the capability for making accurate, high-frequency measurements of nitrate in situ, but have not yet been evaluated for long-term use in groundwater wells. We measured in situ nitrate continuously in two groundwater monitoring wells -one rural and one urban-located in the recharge zone of a productive karst aquifer in central Texas in order to resolve changes that occur over both short-term (hourly to daily) and long-term (monthly to yearly) periods. Nitrate concentrations, measured as nitrate-nitrogen in milligrams per liter (mg/L), during drought conditions showed little or no temporal change as groundwater levels declined. During aquifer recharge, extremely rapid changes in concentration occurred at both wells as documented by hourly data. At both sites, nitrate concentrations were affected by recharging surface water as evidenced by nitrate concentrations in groundwater recharge (0.8-1.3 mg/L) that were similar to previously reported values for regional recharging streams. Groundwater nitrate concentrations responded differently at urban and rural sites during groundwater recharge. Concentrations at the rural well (approximately 1.0 mg/L) increased as a result of higher nitrate concentrations in groundwater recharge relative to ambient nitrate concentrations in groundwater, whereas concentrations at the urban well (approximately 2.7 mg/L) decreased as a result of the dilution of higher ambient nitrate concentrations relative to those in groundwater recharge. Notably, nitrate concentrations decreased to as low as 0.8 mg/L at the urban site during recharge but postrecharge concentrations exceeded 3.0 mg/L. A return to higher nitrate concentrations postrecharge indicates mobilization of a localized source of elevated nitrate within the

  13. Spectroscopic measurement of high-frequency electric fields in the interaction of explosive debris plasma with magnetized background plasma

    Energy Technology Data Exchange (ETDEWEB)

    Bondarenko, A. S., E-mail: AntonBondarenko@ymail.com; Schaeffer, D. B.; Everson, E. T.; Clark, S. E.; Constantin, C. G.; Niemann, C. [Department of Physics and Astronomy, University of California-Los Angeles, Los Angeles, California 90095 (United States)

    2014-12-15

    The collision-less transfer of momentum and energy from explosive debris plasma to magnetized background plasma is a salient feature of various astrophysical and space environments. While much theoretical and computational work has investigated collision-less coupling mechanisms and relevant parameters, an experimental validation of the results demands the measurement of the complex, collective electric fields associated with debris-background plasma interaction. Emission spectroscopy offers a non-interfering diagnostic of electric fields via the Stark effect. A unique experiment at the University of California, Los Angeles, that combines the Large Plasma Device (LAPD) and the Phoenix laser facility has investigated the marginally super-Alfvénic, quasi-perpendicular expansion of a laser-produced carbon (C) debris plasma through a preformed, magnetized helium (He) background plasma via emission spectroscopy. Spectral profiles of the He II 468.6 nm line measured at the maximum extent of the diamagnetic cavity are observed to intensify, broaden, and develop equally spaced modulations in response to the explosive C debris, indicative of an energetic electron population and strong oscillatory electric fields. The profiles are analyzed via time-dependent Stark effect models corresponding to single-mode and multi-mode monochromatic (single frequency) electric fields, yielding temporally resolved magnitudes and frequencies. The proximity of the measured frequencies to the expected electron plasma frequency suggests the development of the electron beam-plasma instability, and a simple saturation model demonstrates that the measured magnitudes are feasible provided that a sufficiently fast electron population is generated during C debris–He background interaction. Potential sources of the fast electrons, which likely correspond to collision-less coupling mechanisms, are briefly considered.

  14. High-frequency complex pitch

    DEFF Research Database (Denmark)

    Santurette, Sébastien; Dau, Torsten

    2012-01-01

    Harmonics in a complex tone are typically considered unresolved when they interact with neighboring harmonics in the cochlea and cannot be heard out separately. Recent studies have suggested that the low pitch evoked by unresolved high-frequency harmonics may be coded via temporal fine-structure ......Harmonics in a complex tone are typically considered unresolved when they interact with neighboring harmonics in the cochlea and cannot be heard out separately. Recent studies have suggested that the low pitch evoked by unresolved high-frequency harmonics may be coded via temporal fine......-structure cues. However, these conclusions rely on the assumptions that combination tones were properly masked and that the ability of listeners to hear out individual partials provides an adequate measure of resolvability. Those assumptions were tested by measuring the audibility of combination tones...... and their effects on pitch matches, the effects of relative component phases and of dichotic presentation, and listeners' ability to hear out individual partials. The results confirmed that combination tones affected pitch, but pitch remained salient when they were masked. The lack of dependence of pitch...

  15. High Frequency, Long Time Series Measurements from the Bermuda Testbed Mooring in Support of SIMBIOS. Chapter 8

    Science.gov (United States)

    Dickey, Tommy; Dobeck, Laura; Sigurdson, David; Zedler, Sarah; Manov, Derek; Yu, Xuri

    2001-01-01

    It has been recognized that optical moorings are important platforms for the validation of Sea-Viewing Wide Field-of-view Sensor (SeaWiFS). It was recommended that optical moorings be maintained in order to: (1) provide long-term time series comparisons between in situ and SeaWIFS measurements of normalized water-leaving radiance; (2) develop and test algorithms for pigment biomass and phytoplankton primary productivity; and (3) provide long-term, virtually continuous in situ observations which can be used to determine and optimize the accuracy of derived satellite products. These applications require the use of in situ radiometers for long periods of time to evaluate and correct for inherent satellite undersampling (aliasing and biasing) and degradation of satellite color sensors (e.g., drifts as experienced by the Coastal Zone Color Scanner). The Bermuda Testbed Mooring (BTM) program was initiated in 1994 at a site located about 80km southeast of Bermuda in waters of about 4530 m depth. In August 1997, with NASA's support, we started to provide the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) program with large volumes of high frequency, long-term time-series bio-optical data from the BTM for SeaWiFS satellite ocean color groundtruthing and algorithm development. This NASA supported portion of the BTM activity spanned three years and covered five BTM deployments. During these three years, the quality of radiometric data has improved dramatically. Excellent agreement between BTM moored data and both SeaWiFS and nearby ship profile radiometric data demonstrate that technical advances in the moored optical observations have reduced the major difficulties that moored platforms face: biofouling and less frequent calibration.

  16. Ballistic-type field penetration into metals illustrated by high- and low-frequency size-effect measurements in silver

    DEFF Research Database (Denmark)

    Gantmakher, V. F.; Lebech, Jens; Bak, Christen Kjeldahl

    1979-01-01

    structure of the field is eliminated because it takes a finite time for an electron to pass the effective region of the trajectory when compared to the time variation of the applied field. Hence only the field between the splash positions remains. The role of different types of trajectories under...... these conditions are discussed on the basis of Pippard's ineffectiveness concept. The Fermi velocities along the belly orbit (B→∥[001]) in silver are extracted from the high-frequency spectra....

  17. New insights into nitrate dynamics in a karst groundwater system gained from in situ high-frequency optical sensor measurements

    Science.gov (United States)

    Opsahl, Stephen P.; Musgrove, MaryLynn; Slattery, Richard N.

    2017-01-01

    Understanding nitrate dynamics in groundwater systems as a function of climatic conditions, especially during contrasting patterns of drought and wet cycles, is limited by a lack of temporal and spatial data. Nitrate sensors have the capability for making accurate, high-frequency measurements of nitrate in situ, but have not yet been evaluated for long-term use in groundwater wells. We measured in situ nitrate continuously in two groundwater monitoring wells —one rural and one urban—located in the recharge zone of a productive karst aquifer in central Texas in order to resolve changes that occur over both short-term (hourly to daily) and long-term (monthly to yearly) periods. Nitrate concentrations, measured as nitrate-nitrogen in milligrams per liter (mg/L), during drought conditions showed little or no temporal change as groundwater levels declined. During aquifer recharge, extremely rapid changes in concentration occurred at both wells as documented by hourly data. At both sites, nitrate concentrations were affected by recharging surface water as evidenced by nitrate concentrations in groundwater recharge (0.8–1.3 mg/L) that were similar to previously reported values for regional recharging streams. Groundwater nitrate concentrations responded differently at urban and rural sites during groundwater recharge. Concentrations at the rural well (approximately 1.0 mg/L) increased as a result of higher nitrate concentrations in groundwater recharge relative to ambient nitrate concentrations in groundwater, whereas concentrations at the urban well (approximately 2.7 mg/L) decreased as a result of the dilution of higher ambient nitrate concentrations relative to those in groundwater recharge. Notably, nitrate concentrations decreased to as low as 0.8 mg/L at the urban site during recharge but postrecharge concentrations exceeded 3.0 mg/L. A return to higher nitrate concentrations postrecharge indicates mobilization of a localized source of elevated nitrate

  18. Diurnal and Seasonal Responses of High Frequency Chlorophyll Fluorescence and PRI Measurements to Abiotic Stress in Almonds

    Science.gov (United States)

    Bambach-Ortiz, N. E.; Paw U, K. T.

    2016-12-01

    Plants have evolved to efficiently utilize light to synthesize energy-rich carbon compounds, and at the same time, dissipate absorbed but excessive photon that would otherwise transfer excitation energy to potentially toxic reactive oxygen species (ROS). Nevertheless, even the most rapidly growing plants with the highest rates of photosynthesis only utilize about half of the light their leaves absorb during the hours of peak irradiance in sun-exposed habitats. Usually, that daily peak of irradiance coincides with high temperature and a high vapor pressure deficit, which are conditions related to plant stomata closure. Consequently, specially in water stressed environments, plants need to have mechanisms to dissipate most of absorbed photons. Plants avoid photo-oxidative damage of the photosynthetic apparatus due to the formation of ROS under excess light using different mechanisms in order to either lower the amount of ROS formation or detoxify already formed ROS. Photoinhibition is defined as a reduction in photosynthetic activity due largely to a sustained reduction in the photochemical efficiency of Photosystem II (PSII), which can be assessed by monitoring Chlorophyll a fluorescence (ChlF). Alternatively, monitoring abiotic stress effects upon photosynthetic activity and photoinhibition may be possible using high frequency spectral reflectance sensors. We aim to find the potential relationships between high frequency PRI and ChlF as indicators of photoinhibition and permanent photodamage at a seasonal scale. Preliminary results show that PRI responses are sensitive to photoinhibition, but provide a poor representation of permanent photodamage observed at a seasonal scale.

  19. [Clinical auxiliary diagnosis value of high frequency ultrasonographic measurements of the thickness of transverse carpal ligaments in carpal tunnel syndrome patients].

    Science.gov (United States)

    Xu, L; Chen, F M; Wang, L; Zhang, P X; Jiang, X R

    2016-04-18

    To evaluate the meaning and value of high-frequency ultrasound in the diagnosis of carpal tunnel syndrome (CTS). In this study, 48 patients (unilateral hand) with CTS were analyzed. The thickness of transverse carpal ligaments at the pisiform bone was measured using high-frequency ultrasound. Open carpal tunnel release procedure was performed in the 48 CTS patients, and the thickness of transverse carpal ligaments at the hamate hook bone measured using vernier caliper under direct vision. The accuracy of thickness of transverse carpal ligaments was evaluated using high-frequency ultrasound. high-frequency ultrasound measurement of thickness of transverse carpal ligaments at the hamate hook bone and pisiform bone, and determination of the diagnostic threshold measurement index using receiver operating characteristic (ROC) curve, sensitivity and specificity were performed and the correlation between the thickness of transverse carpal ligaments and nerve conduction study (NCS) analyzed. The thickness of transverse carpal ligaments in the CTS patients were (0.42±0.08) cm (high-frequency ultrasound) and (0.41±0.06) cm (operation) at hamate hook bone, and there was no significant difference between the two ways (t=0.672, P>0.05). The optimal cut-off value of the transverse carpal ligaments at hamate hook bone was 0.385 cm, the sensitivity 0.775, and the specificity 0.788. The optimal cut-off value of the transverse carpal ligaments at the pisiform bone was 0.315 cm, the sensitivity 0.950, and the specificity 1.000. The transverse carpal ligaments thickness and wrist-index finger sensory nerve conduction velocity (SCV), wrist-middle finger SCV showed a negative correlation. High frequency ultrasound measurements of thickness of transverse carpal ligaments is a valuable method for the diagnosis of CTS.

  20. High-precision real-time 3D shape measurement using a bi-frequency scheme and multi-view system.

    Science.gov (United States)

    Tao, Tianyang; Chen, Qian; Feng, Shijie; Hu, Yan; Da, Jian; Zuo, Chao

    2017-05-01

    High-speed and high-precision 3D shape measurement plays a central role in diverse applications such as automatic online inspection, robotics control, and human-computer interaction. Conventional multi-frame phase-shifting-based fringe projection profilometry techniques face inherent trade-offs between the speed and measurement precision, which are fundamentally limited by the fringe density and extra pattern projections used for de-ambiguity of fringe orders. Increasing the frequency of the projection fringes can obviously improve the measurement precision; however, it creates difficulties in the subsequent phase unwrapping. For this reason, to date, the frequency of the fringes in typical real-time 3D shape measurement techniques is generally less than 30 to guarantee a reasonable reliability of phase unwrapping. To overcome this limitation, a bi-frequency phase-shifting technique based on a multi-view fringe projection system is proposed, which significantly enhances the measurement precision without compromising the measurement speed. Based on the geometric constraints in a multi-view system, the unwrapped phase of the low-frequency (10-period) fringes can be obtained directly, which serves as a reference to unwrap the high-frequency phase map with a total number of periods of up to 160. Besides, the proposed scheme with 10-period and 160-period fringes is suitable for slightly defocusing projection, allowing a higher projection rate and measurement speed. Experiments on both static and dynamic scenes are performed, verifying that our method can achieve high-speed and high-precision 3D measurement at 300 frames per second with a precision of about 50 μm.

  1. High frequency microphone measurements for transition detection on airfoils. Risø B1-18 appendix report

    DEFF Research Database (Denmark)

    Døssing, Mads

    Time series of pressure fluctuations has been obtained using high frequency microphones distributed over the surface of airfoils undergoing wind tunnel tests in the LM Windtunnel, owned by ’LM Glasfiber’, Denmark. The present report describes the dataanalysis, with special attention given...... to transition detection. It is argued that the transition point can be detected by observing the increase in the mean of the Fourier spectre and that thismethod is very stable froma numerical point of view. Other important issues are also discussed, e.g. the variation of pressure standard deviations (sound...

  2. High frequency microphone measurements for transition detection on airfoils. Risø C2-18 appendix report

    DEFF Research Database (Denmark)

    Døssing, Mads

    Time series of pressure fluctuations has been obtained using high frequency microphones distributed over the surface of airfoils undergoing wind tunnel tests in the LM Windtunnel, owned by ’LM Glasfiber’, Denmark. The present report describes the dataanalysis, with special attention given...... to transition detection. It is argued that the transition point can be detected by observing the increase in the mean of the Fourier spectre and that thismethod is very stable froma numerical point of view. Other important issues are also discussed, e.g. the variation of pressure standard deviations (sound...

  3. Measurement of Nonlinear Coefficients of Crystals at Terahertz Frequencies via High Field THz at the FELIX FEL

    Science.gov (United States)

    2017-04-02

    Mid-IR) or FIR, with the exception of measurements in and around 10 μm by means of CO2 lasers [1]. Nothing at all exists for the THz regime. Generally...of high power to enable the measurement of nonlinear phenomena. It is desirable that the source laser is short pulsed to achieve high peak power while...The macropulse energy Emacro is dependent on the operating wavelength of the laser , measured at the sample position Emacro = 0.7 mJ for λ = 20 μm

  4. Geographies of High Frequency Trading

    DEFF Research Database (Denmark)

    Grindsted, Thomas Skou

    2016-01-01

    This paper investigates the geographies of high frequency trading. Today shares shift hands within micro seconds, giving rise to a form of financial geographies termed algorithmic capitalism. This notion refers to the different spatio-temporalities produced by high frequency trading, under...... the valuation of time. As high frequency trading accelerates financial markets, the paper examines the spatio-temporalities of automated trading by the ways in which the speed of knowledge exploitation in financial markets is not only of interest, but also the expansion between different temporalities....... The paper demonstrates how the intensification of time-space compression produces radical new dynamics in the financial market and develops information rent in HFT as convertible to a time rent and a spatio-temporal rent. The final section discusses whether high frequency trading only responds to crises...

  5. Error Analysis of High Frequency Core Loss Measurement for Low-Permeability Low-Loss Magnetic Cores

    DEFF Research Database (Denmark)

    Niroumand, Farideh Javidi; Nymand, Morten

    2016-01-01

    in magnetic cores is B-H loop measurement where two windings are placed on the core under test. However, this method is highly vulnerable to phase shift error, especially for low-permeability, low-loss cores. Due to soft saturation and very low core loss, low-permeability low-loss magnetic cores are favorable...... in many of the high-efficiency high power-density power converters. Magnetic powder cores, among the low-permeability low-loss cores, are very attractive since they possess lower magnetic losses in compared to gapped ferrites. This paper presents an analytical study of the phase shift error in the core....... The analysis has been validated by experimental measurements for relatively low-loss magnetic cores with different permeability values....

  6. High-frequency Trader Subjectivity

    DEFF Research Database (Denmark)

    Borch, Christian; Lange, Ann-Christina

    2017-01-01

    In this article, we examine the recent shift in financial markets toward high-frequency trading (HFT). This turn is being legitimized with reference to how algorithms are allegedly more rational and efficient than human traders, and less prone to emotionally motivated decisions. We argue......-techniques of the ideal high-frequency trader. We demonstrate that these traders face the challenge of avoiding emotional interference in their algorithms and that they deploy a set of disciplinary self-techniques to curb the importance of emotional attachment....

  7. Measuring low-frequency noise indoors

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2008-01-01

    that is exceeded in 10% of the volume of a room (L10) is proposed as a rational and objective target for a measurement method. In Sweden and Denmark rules exist for measuring low-frequency noise indoors. The performance of these procedures was investigated in three rooms. The results from the Swedish method were...... close to the L10 target, but, due to a doubtful use of C-weighting in the scanning, it may give too low results in case of complex sounds. The Danish method was found to have a high risk of giving results substantially below the target, unless complainants can precisely appoint measurement positions...

  8. Multi-point measurement using two-channel reflectometer with antenna switching for study of high-frequency fluctuations in GAMMA 10

    Science.gov (United States)

    Ikezoe, R.; Ichimura, M.; Okada, T.; Itagaki, J.; Hirata, M.; Sumida, S.; Jang, S.; Izumi, K.; Tanaka, A.; Yoshikawa, M.; Kohagura, J.; Sakamoto, M.; Nakashima, Y.

    2017-03-01

    A two-channel microwave reflectometer system with fast microwave antenna switching capability was developed and applied to the GAMMA 10 tandem mirror device to study high-frequency small-amplitude fluctuations in a hot mirror plasma. The fast switching of the antennas is controlled using PIN diode switches, which offers the significant advantage of reducing the number of high-cost microwave components and digitizers with high bandwidths and large memory that are required to measure the spatiotemporal behavior of the high-frequency fluctuations. The use of two channels rather than one adds the important function of a simultaneous two-point measurement in either the radial direction or the direction of the antenna array to measure the phase profile of the fluctuations along with the normal amplitude profile. The density fluctuations measured using this system clearly showed the high-frequency coherent fluctuations that are associated with Alfvén-ion-cyclotron (AIC) waves in GAMMA 10. A correlation analysis applied to simultaneously measured density fluctuations showed that the phase component that was included in a reflected microwave provided both high coherence and a clear phase difference for the AIC waves, while the amplitude component showed neither significant coherence nor clear phase difference. The axial phase differences of the AIC waves measured inside the hot plasma confirmed the formation of a standing wave structure. The axial variation of the radial profiles was evaluated and a clear difference was found among the AIC waves for the first time, which would be a key to clarify the unknown boundary conditions of the AIC waves.

  9. Applying high-frequency surrogate measurements and a wavelet-ANN model to provide early warnings of rapid surface water quality anomalies.

    Science.gov (United States)

    Shi, Bin; Wang, Peng; Jiang, Jiping; Liu, Rentao

    2018-01-01

    It is critical for surface water management systems to provide early warnings of abrupt, large variations in water quality, which likely indicate the occurrence of spill incidents. In this study, a combined approach integrating a wavelet artificial neural network (wavelet-ANN) model and high-frequency surrogate measurements is proposed as a method of water quality anomaly detection and warning provision. High-frequency time series of major water quality indexes (TN, TP, COD, etc.) were produced via a regression-based surrogate model. After wavelet decomposition and denoising, a low-frequency signal was imported into a back-propagation neural network for one-step prediction to identify the major features of water quality variations. The precisely trained site-specific wavelet-ANN outputs the time series of residual errors. A warning is triggered when the actual residual error exceeds a given threshold, i.e., baseline pattern, estimated based on long-term water quality variations. A case study based on the monitoring program applied to the Potomac River Basin in Virginia, USA, was conducted. The integrated approach successfully identified two anomaly events of TP variations at a 15-minute scale from high-frequency online sensors. A storm event and point source inputs likely accounted for these events. The results show that the wavelet-ANN model is slightly more accurate than the ANN for high-frequency surface water quality prediction, and it meets the requirements of anomaly detection. Analyses of the performance at different stations and over different periods illustrated the stability of the proposed method. By combining monitoring instruments and surrogate measures, the presented approach can support timely anomaly identification and be applied to urban aquatic environments for watershed management. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. High-Frequency Seafloor Acoustics

    CERN Document Server

    Jackson, Darrell R

    2007-01-01

    High-Frequency Seafloor Acoustics is the first book in a new series sponsored by the Office of Naval Research on the latest research in underwater acoustics. This exciting new title provides ready access to experimental data, theory, and models relevant to high-frequency seafloor acoustics and will be of interest to sonar engineers and researchers working in underwater acoustics. The physical characteristics of the seafloor affecting acoustic propagation and scattering are covered, including physical and geoacoustic properties and surface roughness. Current theories for acoustic propagation in sediments are presented along with corresponding models for reflection, scattering, and seafloor penetration. The main text is backed up by an extensive bibliography and technical appendices.

  11. Extremely high frequency RF effects on electronics.

    Energy Technology Data Exchange (ETDEWEB)

    Loubriel, Guillermo Manuel; Vigliano, David; Coleman, Phillip Dale; Williams, Jeffery Thomas; Wouters, Gregg A.; Bacon, Larry Donald; Mar, Alan

    2012-01-01

    The objective of this work was to understand the fundamental physics of extremely high frequency RF effects on electronics. To accomplish this objective, we produced models, conducted simulations, and performed measurements to identify the mechanisms of effects as frequency increases into the millimeter-wave regime. Our purpose was to answer the questions, 'What are the tradeoffs between coupling, transmission losses, and device responses as frequency increases?', and, 'How high in frequency do effects on electronic systems continue to occur?' Using full wave electromagnetics codes and a transmission-line/circuit code, we investigated how extremely high-frequency RF propagates on wires and printed circuit board traces. We investigated both field-to-wire coupling and direct illumination of printed circuit boards to determine the significant mechanisms for inducing currents at device terminals. We measured coupling to wires and attenuation along wires for comparison to the simulations, looking at plane-wave coupling as it launches modes onto single and multiconductor structures. We simulated the response of discrete and integrated circuit semiconductor devices to those high-frequency currents and voltages, using SGFramework, the open-source General-purpose Semiconductor Simulator (gss), and Sandia's Charon semiconductor device physics codes. This report documents our findings.

  12. Frequency Control Performance Measurement and Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Illian, Howard F.

    2010-12-20

    Frequency control is an essential requirement of reliable electric power system operations. Determination of frequency control depends on frequency measurement and the practices based on these measurements that dictate acceptable frequency management. This report chronicles the evolution of these measurements and practices. As technology progresses from analog to digital for calculation, communication, and control, the technical basis for frequency control measurement and practices to determine acceptable performance continues to improve. Before the introduction of digital computing, practices were determined largely by prior experience. In anticipation of mandatory reliability rules, practices evolved from a focus primarily on commercial and equity issues to an increased focus on reliability. This evolution is expected to continue and place increased requirements for more precise measurements and a stronger scientific basis for future frequency management practices in support of reliability.

  13. Note: Ultra-high frequency ultra-low dc power consumption HEMT amplifier for quantum measurements in millikelvin temperature range.

    Science.gov (United States)

    Korolev, A M; Shnyrkov, V I; Shulga, V M

    2011-01-01

    We have presented theory and experimentally demonstrated an efficient method for drastically reducing the power consumption of the rf/microwave amplifiers based on HEMT in unsaturated dc regime. Conceptual one-stage 10 dB-gain amplifier showed submicrowatt level of the power consumption (0.95 μW at frequency of 0.5 GHz) when cooled down to 300 mK. Proposed technique has a great potential to design the readout amplifiers for ultra-deep-cooled cryoelectronic quantum devices.

  14. Direct high-precision measurement of the effective optical path length of multi-pass cell with optical frequency domain reflectometer.

    Science.gov (United States)

    Du, Z H; Gao, H; Cao, X H

    2016-01-11

    Multi-pass cells (MPCs) are commonly used in trace-gas detection and weak spectrum measurement. It is essential to accomplish a high-precision measurement of MPCs' effective optical path length (EOPL). A direct high-precision measuring method of MPCs' EOPL with optical frequency domain reflectometer (OFDR) was reported and demonstrated in this paper. Several important parameters of a MPC, such as EOPL and base length, were derived with high-precision by identifying the complicated signal of OFDR. The MPC's EOPL was also verified with the prevailing absorbance method. The results showed that the MPC's EOPL measured by each of these two methods is highly consistent. However, the relative uncertainty with the OFDR dramatically decreased 2 orders of magnitude (about 0.0085%) than that with the absorbance method. It demonstrated that the OFDR method with fewer measurement links is more conducive to a direct measurement. The performances of beam spread and stray light in the White-cell were also evaluated with the method.

  15. A novel system for rapid measurement of high-frequency magnetic properties of toroidal cores of different sizes

    CERN Document Server

    Derebasi, N; Moses, A J; Fox, D

    2000-01-01

    A novel system for power loss and B-H measurements on toroidal magnetic cores was built to operate up to 200 kHz. Measurement data taken using sophisticated software at 10 MHz sampling rate and 16-bit resolution shows the system is versatile and can be used to test a wide range of core sizes and materials with an error <+-3%.

  16. High-frequency magnetic components

    CERN Document Server

    Kazimierczuk, Marian K

    2013-01-01

    A unique text on the theory and design fundaments of inductors and transformers, updated with more coverage on the optimization of magnetic devices and many new design examples The first edition is popular among a very broad audience of readers in different areas of engineering and science. This book covers the theory and design techniques of the major types of high-frequency power inductors and transformers for a variety of applications, including switching-mode power supplies (SMPS) and resonant dc-to-ac power inverters and dc-to-dc power converters. It describes eddy-current phenomena (su

  17. The LASI high-frequency ellipticity system

    Energy Technology Data Exchange (ETDEWEB)

    Sternberg, B.K.; Poulton, M.M. [Univ. of Arizona, Tucson, AZ (United States)

    1995-10-01

    A high-frequency, high-resolution, electromagnetic (EM) imaging system has been developed for environmental geophysics surveys. Some key features of this system include: (1) rapid surveying to allow dense spatial sampling over a large area, (2) high-accuracy measurements which are used to produce a high-resolution image of the subsurface, (3) measurements which have excellent signal-to-noise ratio over a wide bandwidth (31 kHz to 32 MHz), (4) large-scale physical modeling to produce accurate theoretical responses over targets of interest in environmental geophysics surveys, (5) rapid neural network interpretation at the field site, and (6) visualization of complex structures during the survey.

  18. High Frequency Guided Wave Virtual Array SAFT

    Science.gov (United States)

    Roberts, R.; Pardini, A.; Diaz, A.

    2003-03-01

    The principles of the synthetic aperture focusing technique (SAFT) are generalized for application to high frequency plate wave signals. It is shown that a flaw signal received in long-range plate wave propagation can be analyzed as if the signals were measured by an infinite array of transducers in an unbounded medium. It is shown that SAFT-based flaw sizing can be performed with as few as three or less actual measurement positions.

  19. High-resolution measurement of differential mode delay of few-mode fiber using phase reference technique for swept-frequency interferometry

    Science.gov (United States)

    Ohno, Shingo; Iida, Daisuke; Toge, Kunihiro; Manabe, Tetsuya

    2018-01-01

    A method is described for the high-resolution measurement of the differential mode delay (DMD) of few-mode fiber based on the frequency-modulated continuous wave (FMCW) technique. With the conventional approach, a wider optical bandwidth is required for higher resolution, however, the effect of chromatic dispersion becomes critical and limits the actual resolution. This paper proposes and demonstrates a phase reference technique for FMCW signals that achieves high-resolution measurements without increasing the optical bandwidth. We can also further improve the resolution of our proposed method by reducing the phase fluctuation with signal averaging. The feasibility of the proposed method is confirmed experimentally with several kinds of FMFs including an offset-spliced fiber where mode couplings occur.

  20. High Temperature Radio Frequency Loads

    CERN Document Server

    Federmann, S; Grudiev, A; Montesinos, E; Syratchev, I

    2011-01-01

    In the context of energy saving and recovery requirements the design of reliable and robust RF power loads which permit a high outlet temperature and high pressure of the cooling water is desirable. Cooling water arriving at the outlet withmore than 150 ◦C and high pressure has a higher value than water with 50 ◦C under low pressure. Conventional RF power loads containing dielectric and magnetic materials as well as sensitive ceramic windows usually do not permit going much higher than 90 ◦C. Here we present and discuss several design concepts for "metal only" RF high power loads. One concept is the application of magnetic steel corrugated waveguides near cutoff – this concept could find practical use above several GHz. Another solution are resonant structures made of steel to be installed in large waveguides for frequencies of 500 MHz or lower. Similar resonant structures above 100 MHz taking advantage of the rather high losses of normal steel may also be used in coaxial line geometries with large di...

  1. Long-term high frequency measurements of ethane, benzene and methyl chloride at Ragged Point, Barbados: Identification of long-range transport events

    Directory of Open Access Journals (Sweden)

    A.T. Archibald

    2015-09-01

    Full Text Available AbstractHere we present high frequency long-term observations of ethane, benzene and methyl chloride from the AGAGE Ragged Point, Barbados, monitoring station made using a custom built GC-MS system. Our analysis focuses on the first three years of data (2005–2007 and on the interpretation of periodic episodes of high concentrations of these compounds. We focus specifically on an exemplar episode during September 2007 to assess if these measurements are impacted by long-range transport of biomass burning and biogenic emissions. We use the Lagrangian Particle Dispersion model, NAME, run forwards and backwards in time to identify transport of air masses from the North East of Brazil during these events. To assess whether biomass burning was the cause we used hot spots detected using the MODIS instrument to act as point sources for simulating the release of biomass burning plumes. Excellent agreement for the arrival time of the simulated biomass burning plumes and the observations of enhancements in the trace gases indicates that biomass burning strongly influenced these measurements. These modelling data were then used to determine the emissions required to match the observations and compared with bottom up estimates based on burnt area and literature emission factors. Good agreement was found between the two techniques highlight the important role of biomass burning. The modelling constrained by in situ observations suggests that the emission factors were representative of their known upper limits, with the in situ data suggesting slightly greater emissions of ethane than the literature emission factors account for. Further analysis was performed concluding only a small role for biogenic emissions of methyl chloride from South America impacting measurements at Ragged Point. These results highlight the importance of long-term high frequency measurements of NMHC and ODS and highlight how these data can be used to determine sources of emissions

  2. High-frequency conductivity of optically excited charge carriers in hydrogenated nanocrystalline silicon investigated by spectroscopic femtosecond pump–probe reflectivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    He, Wei [University of Birmingham, School of Physics and Astronomy, Birmingham B15 2TT (United Kingdom); Yurkevich, Igor V. [Aston University, Nonlinearity and Complexity Research Group, Birmingham B4 7ET (United Kingdom); Zakar, Ammar [University of Birmingham, School of Physics and Astronomy, Birmingham B15 2TT (United Kingdom); Kaplan, Andrey, E-mail: a.kaplan.1@bham.ac.uk [University of Birmingham, School of Physics and Astronomy, Birmingham B15 2TT (United Kingdom)

    2015-10-01

    We report an investigation into the high-frequency conductivity of optically excited charge carriers far from equilibrium with the lattice. The investigated samples consist of hydrogenated nanocrystalline silicon films grown on a thin film of silicon oxide on top of a silicon substrate. For the investigation, we used an optical femtosecond pump–probe setup to measure the reflectance change of a probe beam. The pump beam ranged between 580 and 820 nm, whereas the probe wavelength spanned 770 to 810 nm. The pump fluence was fixed at 0.6 mJ/cm{sup 2}. We show that at a fixed delay time of 300 fs, the conductivity of the excited electron–hole plasma is described well by a classical conductivity model of a hot charge carrier gas found at Maxwell–Boltzmann distribution, while Fermi–Dirac statics is not suitable. This is corroborated by values retrieved from pump–probe reflectance measurements of the conductivity and its dependence on the excitation wavelength and carrier temperature. The conductivity decreases monotonically as a function of the excitation wavelength, as expected for a nondegenerate charge carrier gas. - Highlights: • We study high‐frequency conductivity of excited hydrogenated nanocrystalline silicon. • Reflectance change was measured as a function of pump and probe wavelength. • Maxwell–Boltzmann transport theory was used to retrieve the conductivity. • The conductivity decreases monotonically as a function of the pump wavelength.

  3. Low-frequency vibration measurement by a dual-frequency DBR fiber laser

    Science.gov (United States)

    Zhang, Bing; Cheng, Linghao; Liang, Yizhi; Jin, Long; Guo, Tuan; Guan, Bai-Ou

    2017-09-01

    A dual-frequency distributed Bragg reflector (DBR) fiber laser based sensor is demonstrated for low-frequency vibration measurement through the Doppler effect. The response of the proposed sensor is quite linear and is much higher than that of a conventional accelerometer. The proposed sensor can work down to 1 Hz with high sensitivity. Therefore, the proposed sensor is very efficient in low-frequency vibration measurement.

  4. Investigating the dependence of the temperature of high-intensity discharge (HID) lamp electrodes on the operating frequency by pyrometric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Reinelt, J; Westermeier, M; Ruhrmann, C; Bergner, A; Awakowicz, P; Mentel, J, E-mail: juergen.mentel@ruhr-uni-bochum.de [Ruhr University of Bochum, Electrical Engineering and Plasma Technology, D-44780 Bochum (Germany)

    2011-03-09

    Phase-resolved temperature distributions are determined along a rod-shaped tungsten electrode, by which an ac arc is operated within a model lamp filled with argon. Switched dc and sinusoidal currents are applied with amplitudes of several amperes and operating frequencies being varied between 10 Hz and 10 kHz. The temperature is deduced from the grey body radiation of the electrode being recorded with a spectroscopic measuring system. Phase-resolved values of the electrode tip temperature T{sub tip} and of the power input P{sub in} are determined comparing the measured temperature distributions with the integral of the one-dimensional heat balance with these parameters as integration constants. They are supplemented by phase-resolved measurements of the sum of cathode and anode fall called the electrode sheath voltage. If a switched dc current is applied it is found that both quantities are within the cathodic phase only marginally higher than for a cathode being operated with a dc current. T{sub tip} and P{sub in} start to decrease for low currents and to increase for high currents at the beginning of the anodic phase. But with increasing operating frequency the deviations from the cathodic phase are reduced until they cannot be resolved for frequencies of several kHz. A more pronounced modulation, but the same tendencies, is observed with a sinusoidal current waveform. For 10 kHz a diffuse arc attachment with an almost phase-independent electrode tip temperature, which deviates only marginally from that of a dc cathode, and an electrode sheath voltage proportional to the arc current is established with both current waveforms.

  5. High-frequency measurement of depressive severity in a patient treated for severe treatment-resistant depression with deep-brain stimulation.

    Science.gov (United States)

    Sani, S; Busnello, J; Kochanski, R; Cohen, Y; Gibbons, R D

    2017-08-15

    Although there have been previous studies of deep-brain stimulation (DBS), we present, to our knowledge, the first example of high-frequency depressive severity measurement-based DBS treatment in particular and psychiatric treatment in general. Daily post-surgical e-mail prompts for a period of 6 months resulted in 93 administrations of a computerized adaptive test (CAT) of depression severity (CAT-Depression Inventory or CAT-DI) via the internet. There was an average of 3.37 weekly measurements with an average separation of 2.12 days. No additional incentive was provided to the patient for completing the adaptive tests. The patient is a 55-year-old female with six psychiatric hospitalizations for depression, two suicide attempts, marginal response to eight electroconvulsive therapy (ECT) treatments and 35 psychotropic medications. We report results after high-frequency stimulation of the superolateral branch of the medial forebrain bundle. The CAT-DI was used for daily assessments before, during and after (remotely in response to an e-mail prompt) the DBS procedure. Two follow-up Hamilton Depression Scales (HAM-Ds) were also collected. Response to treatment varied markedly, with a decrease from severe (>75) to mild (60), which is three times the size of the uncertainty level. Although the HAM-D scores decreased, they missed the more complete temporal pattern identified by CAT-DI daily monitoring. We demonstrated feasibility of daily depressive severity measurement at high levels of precision and compliance. Clinician ratings confirm the general pattern of treatment benefit, but mask the marked variability in mood and more marked periods of benefit and decline.

  6. Quantifying Ozone Production throughout the Boundary Layer from High Frequency Tethered Profile Measurements during a High Ozone Episode in the Uinta Basin, Utah

    Science.gov (United States)

    Sterling, C. W.; Johnson, B.; Schnell, R. C.; Oltmans, S. J.; Cullis, P.; Hall, E. G.; Jordan, A. F.; Windell, J.; McClure-Begley, A.; Helmig, D.; Petron, G.

    2015-12-01

    During the Uinta Basin Winter Ozone Study (UBWOS) in Jan - Feb 2013, 735 tethered ozonesonde profiles were obtained at 3 sites including during high wintertime photochemical ozone production events that regularly exceeded 125 ppb. High resolution profiles of ozone and temperature with altitude, measured during daylight hours, showed the development of approximately week long high ozone episodes building from background levels of ~40 ppb to >150 ppb. The topography of the basin combined with a strong temperature inversion trapped oil and gas production effluents in the basin and the snow covered surface amplified the sun's radiation driving the photochemical ozone production at rates up to 13 ppb/hour in a cold layer capped at 1600-1700 meters above sea level. Beginning in mid-morning, ozone mixing ratios throughout the cold layer increased until late afternoon. Ozone mixing ratios were generally constant with height indicating that ozone production was nearly uniform throughout the depth of the cold pool. Although there was strong diurnal variation, ozone mixing ratios increased during the day more than decreased during the night, resulting in elevated levels the next morning; an indication that nighttime loss processes did not compensate for daytime production. Even though the 3 tethersonde sites were at elevations differing by as much as 140 m, the top of the high ozone layer was nearly uniform in altitude at the 3 locations. Mobile van surface ozone measurements across the basin confirmed this capped structure of the ozone layer; the vehicle drove out of high ozone mixing ratios at an elevation of ~1900 meters above sea level, above which free tropospheric ozone mixing ratios of ~50 ppb were measured. Exhaust plumes from a coal-fired power plant in the eastern portion of the basin were intercepted by the tethersondes. The structure of the profiles clearly showed that effluents in the plumes were not mixed downward and thus did not contribute precursor nitrogen

  7. High spectral purity Kerr frequency comb radio frequency photonic oscillator.

    Science.gov (United States)

    Liang, W; Eliyahu, D; Ilchenko, V S; Savchenkov, A A; Matsko, A B; Seidel, D; Maleki, L

    2015-08-11

    Femtosecond laser-based generation of radio frequency signals has produced astonishing improvements in achievable spectral purity, one of the basic features characterizing the performance of an radio frequency oscillator. Kerr frequency combs hold promise for transforming these lab-scale oscillators to chip-scale level. In this work we demonstrate a miniature 10 GHz radio frequency photonic oscillator characterized with phase noise better than -60 dBc Hz(-1) at 10 Hz, -90 dBc Hz(-1) at 100 Hz and -170 dBc Hz(-1) at 10 MHz. The frequency stability of this device, as represented by Allan deviation measurements, is at the level of 10(-10) at 1-100 s integration time-orders of magnitude better than existing radio frequency photonic devices of similar size, weight and power consumption.

  8. Econometrics of financial high-frequency data

    CERN Document Server

    Hautsch, Nikolaus

    2011-01-01

    This book covers major approaches in high-frequency econometrics. It discusses implementation details, provides insights into properties of high-frequency data as well as institutional settings and presents applications.

  9. Combining an automated closed chamber system with a quantum cascade laser for high-frequency measurements of δ13C of ecosystem CO2 fluxes

    Science.gov (United States)

    Brændholt, Andreas; Ibrom, Andreas; Ambus, Per; Steenberg Larsen, Klaus; Pilegaard, Kim

    2017-04-01

    Advances in laser spectroscopy have allowed for online high-frequency measurements of the isotopic composition of C and O in CO2, thereby providing new ways to investigate CO2 flux partitioning and carbon cycling in natural ecosystems. In this study, we combined an Aerodyne quantum cascade laser for CO2 isotopes with the LI-COR LI-8100A/8150 automatic closed chamber system to yield the δ13C of CO2 during automated closed chamber measurements. The system was used during a two month campaign in a Danish beech forest, where δ13C was measured for a total of 12 chambers, each enclosing either intact soil, trenched soil, tree stem or a tree root. By applying the Keeling plot methodology to the change in δ13C of CO2 during a chamber measurement, the isotopic composition of the respired CO2 was determined. The poster presents δ13C data of ecosystem CO2 fluxes on both a daily and diel scale for soil, roots and tree stems that revealed interesting information about forest ecosystem carbon cycling. Furthermore, it explores the unique setup and the tests required for precise automated chamber-based measurements of δ13C by a quantum cascade laser. Acknowledgements: This study was funded by the free Danish Ministry for Research, Innovation and higher Education, the free Danish Research Council (DFF - 1323-00182).

  10. Frequency dependence of lung volume changes during superimposed high-frequency jet ventilation and high-frequency jet ventilation.

    Science.gov (United States)

    Sütterlin, R; Priori, R; Larsson, A; LoMauro, A; Frykholm, P; Aliverti, A

    2014-01-01

    Superimposed high-frequency jet ventilation (SHFJV) has proved to be safe and effective in clinical practice. However, it is unclear which frequency range optimizes ventilation and gas exchange. The aim of this study was to systematically compare high-frequency jet ventilation (HFJV) with HFJV by assessing chest wall volume variations (ΔEEV(CW)) and gas exchange in relation to variable high frequency. SHFJV or HFJV were used alternatively to ventilate the lungs of 10 anaesthetized pigs (21-25 kg). The low-frequency component was kept at 16 min(-1) in SHFJV. In both modes, high frequencies ranging from 100 to 1000 min(-1) were applied in random order and ventilation was maintained for 5 min in all modalities. Chest wall volume variations were obtained using opto-electronic plethysmography. Airway pressures and arterial blood gases were measured repeatedly. SHFJV increased ΔEEV(CW) compared with HFJV; the difference ranged from 43 to 68 ml. Tidal volume (V(T)) was always >240 ml during SHFJV whereas during HFJV ranged from 92 ml at the ventilation frequency of 100 min(-1) to negligible values at frequencies >300 min(-1). We observed similar patterns for Pa(O₂) and Pa(CO₂). SHFJV provided generally higher, frequency-independent oxygenation (Pa(O₂) at least 32.0 kPa) and CO₂ removal (Pa(CO₂) ∼5.5 kPa), whereas HFJV led to hypoxia and hypercarbia at higher rates (Pa(O₂) 10 kPa at f(HF)>300 min(-1)). In a porcine model, SHFJV was more effective in increasing end-expiratory volume than single-frequency HFJV, but both modes may provide adequate ventilation in the absence of airway obstruction and respiratory disease, except for HFJV at frequencies ≥300 min(-1).

  11. High frequency ultrasound measurements on a translucent thin bioglass, based on Si, Ca, Na: Study of the distribution of elastic modulus

    Science.gov (United States)

    Bachar, Ahmed; Nassar, Georges; Mercier, Cyrille; Bouchart, Franck; Follet, Claudine; Amrousse, Rachid; Kazan, Michel

    2013-11-01

    In this work, an ultrasonic high frequency focused sensor (100 MHz) has been used to study the variation of the elastic modulus of a thin bioglass element, based on Si, Ca, Na. In fact, physical functionalization of materials may play a role in defining the properties of interfaces of the surface depending of the physico-chemical characteristics of the materials used. The study is restricted to the characterization by an ultrasonic method of the elastic modulus profile of the bioglass element during the final phase of processing: before and after thermal treatment. The initial objective is to produce an ultrasonic map of the element under investigation, such as a substrate, prior to further tests involving adhesion of biological cells in order to try to understand the relationship between the distribution of the measured mechanical properties and the adhesion phenomenon.

  12. Investigation of the electronic structure of the primary electron donor in bacterial photosynthesis. Measurements of the anisotropy of the electronic G-tensor using high-field/high-frequency EPR

    Energy Technology Data Exchange (ETDEWEB)

    Huber, M. [Institut fuer Organische Chemie, FU Berlin, Berlin (Germany); Toerring, J.T.; Plato, M.; Moebius, K. [Institut fuer Experimentalphysik, FU Berlin, Berlin (Germany); Fink, U.; Lubitz, W. [Max-Volmer Institut, TU Berlin, Berlin (Germany); Feick, R. [Max-Planck-Institut fuer Biochemie, Martinsried (Germany); Schenck, C.C. [Department of Biochemistry, Colorado State University, Fort Collins (United States)

    1995-08-01

    Cation radicals of the primary electron donor (D{sup +}) in bacterial photosynthesis were investigated by high field, high frequency (95 GHz) EPR. Measurements on frozen solutions of D{sup +}, a dimeric {pi}-cation radical, of various organisms (Rps. viridis, Rb. sphaeroides, Chloroflexus aurantiacus and a heterodimer mutant) are reported, revealing differences in the principal values of the G-tensor. Elements of a theory relating the magnitudes of G principal values to the electronic structure are discussed

  13. Reprint of "Non-invasive measure of respiratory mechanics and conventional respiratory parameters in conscious large animals by high frequency Airwave Oscillometry".

    Science.gov (United States)

    Bassett, Leanne; Troncy, Eric; Robichaud, Annette; Schuessler, Thomas F; Pouliot, Mylène; Ascah, Alexis; Authier, Simon

    2014-01-01

    A number of drugs in clinical trials are discontinued due to potentially life-threatening airway obstruction. As some drugs may not cause changes in core battery parameters such as tidal volume (Vt), respiratory rate (RR) or minute ventilation (MV), including measurements of respiratory mechanics in safety pharmacology studies represents an opportunity for design refinement. The present study aimed to test a novel non-invasive methodology to concomitantly measure respiratory system resistance (Rrs) and conventional respiratory parameters (Vt, RR, MV) in conscious Beagle dogs and cynomolgus monkeys. An Airwave Oscillometry system (tremoFlo; THORASYS Inc., Montreal, Canada) was used to concomitantly assess Rrs and conventional respiratory parameters before and after intravenous treatment with a bronchoactive agent. Respiratory mechanics measurements were performed by applying a short (i.e. 16s) single high frequency (19Hz) waveform at the subject's airway opening via a face mask. During measurements, pressure and flow signals were recorded. After collection of baseline measurements, methacholine was administered intravenously to Beagle dogs (n=6) and cynomolgus monkeys (n=4) at 8 and 68μg/kg, respectively. In dogs, methacholine induced significant increases in Vt, RR and MV while in monkeys, it only augmented RR. A significant increase in Rrs was observed after methacholine administration in both species with mean percentage peak increases from baseline of 88 (53)% for dogs and 28 (16)% for cynomolgus monkeys. Airwave Oscillometry appears to be a promising non-invasive methodology to enable respiratory mechanics measurements in conscious large animals, a valuable refinement in respiratory safety pharmacology. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Measurement of high frequency conductivity of oxide-doped anti-ferromagnetic thin film with a near-field scanning microwave microscope

    Directory of Open Access Journals (Sweden)

    Z. Wu

    2014-04-01

    Full Text Available In this manuscript, we describe how the map of high frequency conductivity distribution of an oxide-doped anti-ferromagnetic 200 nm thin film can be obtained from the quality factor (Q measured by a near-field scanning microwave microscope (NSMM. Finite element analysis (FEA is employed to simulate the NSMM tip-sample interaction and obtain a curve related between the simulated quality factor (Q and conductivity. The curve is calibrated by a standard Cu thin film with thickness of 200 nm, together with NSMM measured Q of Ag, Au, Fe, Cr and Ti thin films. The experimental conductivity obtained by the NSMM for IrMn thin films with various doped concentrations of Al2O3 is found consistent with conventional voltammetry measurement in the same tendency. That conductivity decreases as the content of doped Al2O3 increases. The results and images obtained demonstrate that NSMM can be employed in thin film analysis for characterization of local electrical properties of materials in a non-destructive manner and for obtaining a map of conductivity distribution on the same film.

  15. Measurement Duration and Frequency Impact Objective Light Exposure Measures.

    Science.gov (United States)

    Ulaganathan, Sekar; Read, Scott A; Collins, Michael J; Vincent, Stephen J

    2017-05-01

    To determine the measurement duration and frequency required to reliably quantify the typical personal light exposure patterns of children and young adults. Ambient light exposure data were obtained from 31 young adults and 30 children using a wrist-worn light sensor configured to measure ambient light exposure every 30 seconds for 14 days. To examine the influence of measurement duration upon light exposure, the daily time exposed to outdoor light levels (>1000 lux) was initially calculated based upon data from all 14 days and then recalculated from 12, 10, 8, 6, 4, and 2 randomly selected days. To examine the influence of measurement frequency, the outdoor exposure time was calculated for a 30-second sampling rate and again after resampling at 1-, 2-, 3-, 4-, 5-, and 10-minute sampling rates. Children spent significantly greater time outdoors (44 minutes higher [95% CI: 26, 62]) compared to adults (P = .001). Children spent more time outdoors during the weekdays (13 minutes higher [-7, 32]) and adults spent more time outdoors during the weekends (24 minutes higher [7, 40]) (P = .005). Calculating light exposure using a lower number of days and coarser sampling frequencies did not significantly alter the group mean light exposure (P > .05). However, a significant increase in measurement variability occurred for outdoor light exposure derived from less than 8 days and 3 minutes or coarser measurement frequencies in adults, and from less than 8 days and 4 minutes or coarser frequencies in children (all P measurement duration seemed to have a greater impact upon measurement variability than reducing the measurement frequency. These findings suggest that a measurement duration of at least 1 week and a measurement frequency of 2 minutes or finer provides the most reliable estimates of personal outdoor light exposure measures in children and young adults.

  16. Combined investigations on long-term hydrochemical monitoring and high frequency measurements in the Critical Zone from the Auradé catchment (SW, France)

    Science.gov (United States)

    Ponnou-Delaffon, Vivien; Probst, Anne; Payre-Suc, Virginie; Ferrant, Sylvain; Probst, Jean-Luc

    2017-04-01

    The Critical Zone (CZ) is now well identified as the land-atmosphere interface under the influence of many human pressures rendering up vulnerable for future generations. Although many investigations have been undergone over the last 30 years in the different compartments of the CZ, it remains important to understand the overall functioning of this area in a context of global change. A long-term hydrological and chemical monitoring was performed since 30 years for nitrates and discharge, and for 10 years for major elements at the stream outlet of a small agricultural carbonated catchment (Auradé site). This catchment is part of the observatories network OZCAR infrastructure and since 1992 it was a pilot for improving agricultural practices. Two time scales were investigated based on a discrete sampling during low water flow and hydrological events, and since 2006 on high frequency datas (every 10mn) for pH, conductivity, nitrate, temperature…using a multiparameter probe. The long-term trends indicated mostly a decreasing in nitrate, Ca and Mg concentrations namely and an increase in DOC, which can be related to the influence of the environmental practices (fertilizers inputs, vegetative filter strip etc..), but more recently to the changes in temperature and hydrological patterns (decreasing discharge and occurrence of rare but intensive events). The high frequency measurements on short-term events allowed: (i) to highlight the mechanisms involved in flux exportations (nycthemeral cycle for nitrates as ex.), (ii) to reconstruct the chemical patterns by correlating the parameters to major elements, and finally (iii) to have a better and more precise approach of the contribution of weathering and land use on the hydrochemical functioning of the CZ, particularly on the disturbance of carbon cycle by anthropogenic fingerprints.

  17. High-frequency Rayleigh-wave method

    Science.gov (United States)

    Xia, J.; Miller, R.D.; Xu, Y.; Luo, Y.; Chen, C.; Liu, J.; Ivanov, J.; Zeng, C.

    2009-01-01

    High-frequency (???2 Hz) Rayleigh-wave data acquired with a multichannel recording system have been utilized to determine shear (S)-wave velocities in near-surface geophysics since the early 1980s. This overview article discusses the main research results of high-frequency surface-wave techniques achieved by research groups at the Kansas Geological Survey and China University of Geosciences in the last 15 years. The multichannel analysis of surface wave (MASW) method is a non-invasive acoustic approach to estimate near-surface S-wave velocity. The differences between MASW results and direct borehole measurements are approximately 15% or less and random. Studies show that simultaneous inversion with higher modes and the fundamental mode can increase model resolution and an investigation depth. The other important seismic property, quality factor (Q), can also be estimated with the MASW method by inverting attenuation coefficients of Rayleigh waves. An inverted model (S-wave velocity or Q) obtained using a damped least-squares method can be assessed by an optimal damping vector in a vicinity of the inverted model determined by an objective function, which is the trace of a weighted sum of model-resolution and model-covariance matrices. Current developments include modeling high-frequency Rayleigh-waves in near-surface media, which builds a foundation for shallow seismic or Rayleigh-wave inversion in the time-offset domain; imaging dispersive energy with high resolution in the frequency-velocity domain and possibly with data in an arbitrary acquisition geometry, which opens a door for 3D surface-wave techniques; and successfully separating surface-wave modes, which provides a valuable tool to perform S-wave velocity profiling with high-horizontal resolution. ?? China University of Geosciences (Wuhan) and Springer-Verlag GmbH 2009.

  18. Uncertainty Measures of Regional Flood Frequency Estimators

    DEFF Research Database (Denmark)

    Rosbjerg, Dan; Madsen, Henrik

    1995-01-01

    Regional flood frequency models have different assumptions regarding homogeneity and inter-site independence. Thus, uncertainty measures of T-year event estimators are not directly comparable. However, having chosen a particular method, the reliability of the estimate should always be stated, e...

  19. High frequency pressure oscillator for microcryocoolers

    NARCIS (Netherlands)

    Vanapalli, Srinivas; ter Brake, Hermanus J.M.; Jansen, Henricus V.; Zhao, Yiping; Holland, Herman J.; Burger, Johannes Faas; Elwenspoek, Michael Curt

    2008-01-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency

  20. Using paired in situ high frequency nitrate measurements to better understand controls on nitrate concentrations and estimate nitrification rates in a wastewater-impacted river

    Science.gov (United States)

    Kraus, Tamara; O'Donnell, Katy; Downing, Bryan D.; Burau, Jon R.; Bergamaschi, Brian

    2017-01-01

    We used paired continuous nitrate ( ) measurements along a tidally affected river receiving wastewater discharge rich in ammonium ( ) to quantify rates of change in  concentration ( ) and estimate nitrification rates.  sensors were deployed 30 km apart in the Sacramento River, California (USA), with the upstream station located immediately above the regional wastewater treatment plant (WWTP). We used a travel time model to track water transit between the stations and estimated  every 15 min (October 2013 to September 2014). Changes in concentration were strongly related to water temperature. In the presence of wastewater, was generally positive, ranging from about 7 µM d−1 in the summer to near zero in the winter. Numerous periods when the WWTP halted discharge allowed the  to be estimated under no-effluent conditions and revealed that in the absence of effluent, net gains in  were substantially lower but still positive in the summer and negative (net sink) in the winter. Nitrification rates of effluent-derived NH4 ( ) were estimated from the difference between  measured in the presence versus absence of effluent and ranged from 1.5 to 3.4 µM d−1, which is within literature values but tenfold greater than recently reported for this region.  was generally lower in winter (∼2 µM d−1) than summer (∼3 µM d−1). This in situ, high frequency approach provides advantages over traditional discrete sampling, incubation, and tracer methods and allows measurements to be made over broad areas for extended periods of time. Incorporating this approach into environmental monitoring programs can facilitate our ability to protect and manage aquatic systems.

  1. Measurement of background translocation frequencies in individuals with clones

    Energy Technology Data Exchange (ETDEWEB)

    Wade, Marcelle J. [California State Univ. (CalState), Hayward, CA (United States)

    1996-08-01

    In the leukemia case the unseparated B and T lymphocytes had a high translocation frequency even after 0.0014, respectively. After purging all clones from the data, the translocation frequencies for Bio 8 and Bio 23 were 0.00750.0014 and 0.0073 metaphases were scored for chromosomal aberrations,, specifically reciprocal translocations, using fluorescence in situ hybridization (FISH). Metaphase spreads were used from two healthy, unexposed individuals (not exposed to radiation, chemotherapy or radiotherapy) and one early B- precursor acute lymphocytic leukemia (ALL) patient (metaphase spreads from both separated T lymphocytes and unseparated B and T lymphocytes were scored). All three individuals had an abnormally high translocation frequency. The high translocation frequencies resulted from clonal expansion of specific translocated chromosomes. I show in this thesis that by purging (discounting or removing) clones from the data of unexposed individuals, one can obtain true background translocation frequencies. In two cases, Bio 8 and Bio 23, the measured translocation frequency for chromosomes 1, 2 and 4 was 0.0124 purging all of the clones from the data. This high translocation frequency may be due to a low frequency of some clones and may not be recognized. The separated T lymphocytes had a higher translocation frequency than expected.

  2. OceanCubes: An Affordable Cabled Observatory System for Integrated Long-Term, High Frequency Biological, Chemical, and Physical Measurements for Understanding Coastal Ecosystems

    Science.gov (United States)

    Gallager, S. M.

    2016-02-01

    Understanding how coastal ocean processes are forcing and/or responding to ecosystem change is a central premise in current oceanographic research and monitoring. A distributed, high capacity observing capability is necessary to address biological processes requiring high frequency observations on short ( turbulence, internal waves), moderate (typhoons), and decadal time scales (e.g., NAO, El Nino-SO, PDO). The current belief that ocean observing systems need to be expensive, large, difficult to deploy and limited in capacity was tested by developing OceanCubes, an end-to-end cabled observational system with real-time telemetry, state-of-the-art sensor packages, high level of expandability, and diver maintained to reduce operating costs. A modular approach allows for a scalable system that can grow over time to accommodate budgets. The control volume design allows for measurement of material flux and energy from the water column to the benthos at a rate of s-1. The sensor package is connected by electro-optical cable to shore providing the capability for internet-based teleoperation by scientists world-wide. The central node provides underwater mateable connections for > 22 serial and Ethernet-based sensors (CTD, four ADCPs, chlorophyll and CDOM fluorescence, O2, nitrate, pCO2, pH, a bio-optical package, a Continuous Plankton Imaging and Classification Sensor (CPICS) for mesoplankton, a pan and tilt webcam, and two stereo cameras to observe and track fish communities. ADCPs and temperature strings mark the corners of the 162,000 m3 control volume. Disparate data streams are remotely archived, correlated, and analyzed while plankton and fish are identified using state-of-the-art machine vision and learning techniques. Two OceanCubes have been installed in Japan (Okinawa and Oshima Island, Tokyo) and have survived several typhoon seasons. Two additional systems are planned for either side of the Panamanian Isthmus. Results of these systems will be discussed.

  3. Pulse shape measurements using single shot-frequency resolved optical gating for high energy (80 J) short pulse (600 fs) laser.

    Science.gov (United States)

    Palaniyappan, S; Shah, R C; Johnson, R; Shimada, T; Gautier, D C; Letzring, S; Jung, D; Hörlein, R; Offermann, D T; Fernández, J C; Hegelich, B M

    2010-10-01

    Relevant to laser based electron/ion accelerations, a single shot second harmonic generation frequency resolved optical gating (FROG) system has been developed to characterize laser pulses (80 J, ∼600 fs) incident on and transmitted through nanofoil targets, employing relay imaging, spatial filter, and partially coated glass substrates to reduce spatial nonuniformity and B-integral. The device can be completely aligned without using a pulsed laser source. Variations of incident pulse shape were measured from durations of 613 fs (nearly symmetric shape) to 571 fs (asymmetric shape with pre- or postpulse). The FROG measurements are consistent with independent spectral and autocorrelation measurements.

  4. Measurement techniques for radio frequency nanoelectronics

    CERN Document Server

    Wallis, T Mitch

    2017-01-01

    Connect basic theory with real-world applications with this practical, cross-disciplinary guide to radio frequency measurement of nanoscale devices and materials.• Learn the techniques needed for characterizing the performance of devices and their constituent building blocks, including semiconducting nanowires, graphene, and other two dimensional materials such as transition metal dichalcogenides• Gain practical insights into instrumentation, including on-wafer measurement platforms and scanning microwave microscopy• Discover how measurement techniques can be applied to solve real-world problems, in areas such as passive and active nanoelectronic devices, semiconductor dopant profiling, subsurface nanoscale tomography, nanoscale magnetic device engineering, and broadband, spatially localized measurements of biological materialsFeaturing numerous practical examples, and written in a concise yet rigorous style, this is the ideal resource for researchers, practicing engineers, and graduate students new to ...

  5. Extreme Low Frequency Acoustic Measurement System

    Science.gov (United States)

    Shams, Qamar A. (Inventor); Zuckerwar, Allan J. (Inventor)

    2017-01-01

    The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.

  6. High frequency pressure oscillator for microcryocoolers

    OpenAIRE

    Vanapalli, Srinivas; ter Brake, Hermanus J.M.; Jansen, Henricus V.; Zhao, Yiping; Holland, Herman J.; Burger, Johannes Faas; Elwenspoek, Michael Curt

    2008-01-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80 K, delivering a cooling power of 10 mW. Piezoelectric actuators operate efficiently at ...

  7. Measurement of low-frequency noise in rooms

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2006-01-01

    Measurement of low-frequency noise in rooms is problematic due to standing wave patterns. The spatial variation in the sound pressure level can typically be as much as 20-30 dB. For assessment of annoyance from low-frequency noise in dwellings, it is important to measure a level close to the high......Measurement of low-frequency noise in rooms is problematic due to standing wave patterns. The spatial variation in the sound pressure level can typically be as much as 20-30 dB. For assessment of annoyance from low-frequency noise in dwellings, it is important to measure a level close...... to the highest level present in a room, rather than a room average level. In order to ensure representative noise measurements, different positions were investigated based on theoretical considerations and observations from numerical room simulations. In addition measurements were performed in three different...... rooms. The sound pressure level was measured 1) in three-dimensional corners and 2) according to current Swedish and Danish measurement methods. Furthermore, the entire sound pressure distributions were measured by scanning. The Swedish and Danish measurement methods include a corner measurement...

  8. High frequency pressure oscillator for microcryocoolers

    Science.gov (United States)

    Vanapalli, S.; ter Brake, H. J. M.; Jansen, H. V.; Zhao, Y.; Holland, H. J.; Burger, J. F.; Elwenspoek, M. C.

    2008-04-01

    Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating between 300 and 80K, delivering a cooling power of 10mW. Piezoelectric actuators operate efficiently at high frequencies and have high power density making them good candidates as drivers for high frequency pressure oscillator. The pressure oscillator described in this work consists of a membrane driven by a piezoelectric actuator. A pressure ratio of about 1.11 was achieved with a filling pressure of 2.5MPa and compression volume of about 22.6mm3 when operating the actuator with a peak-to-peak sinusoidal voltage of 100V at a frequency of 1kHz. The electrical power input was 2.73W. The high pressure ratio and low electrical input power at high frequencies would herald development of microminiature cryocoolers.

  9. Simulation and measurement of the high-frequency properties of a superconducting photoelectron source; Simulation und Messung der Hochfrequenzeigenschaften einer supraleitenden Photo-Elektronenquelle

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Andre

    2012-07-12

    The success of future synchrotron radiation sources and high power IR free-electron lasers (FELs) largely depends on the development of an appropriate electron source. At the moment, the superconducting radio frequency photoinjector (SRF gun) seems to be a promising approach to achieve the required brightness and the high average current at the same time. Within the present thesis a SRF gun was brought into operation and essential characteristics could be investigated. To date this is the only source, which is equipped with all components and operated at a linear accelerator.

  10. High-frequency behavior of magnetic composites

    Science.gov (United States)

    Lagarkov, Andrey N.; Rozanov, Konstantin N.

    2009-07-01

    The paper reviews recent progress in the field of microwave magnetic properties of composites. The problem under discussion is developing composites with high microwave permeability that are needed in many applications. The theory of magnetic composites is briefly sketched with the attention paid to the laws governing the magnetic frequency dispersion in magnetic materials and basic mixing rules for composites. Recent experimental reports on the microwave performance of magnetic composites, as well as data on the agreement of the mixing rules with the measured permeability of composites that are available from the literature are discussed. From the data, a conclusion is made that the validity of a mixing rule is determined by the permeability contrast in the composite, i.e., the difference between permeability of inclusions and that of the host matrix. When the contrast is low, the Maxwell Garnet mixing rule is frequently valid. When the contrast is high, which is of the most interest for obtaining high microwave permeability of a composite, no conventionally accepted theory is capable of accurately predicting the permeability of the composites. Therefore, the mixing rules do not allow the microwave properties of magnetic composites to be predicted when the permeability of inclusions is high, that is the case of the most interest. Because of that, general limitations to the microwave performance of composites are of importance. In particular, an important relation constraining the microwave permeability of composites follows from Kittel's theory of ferromagnetic resonance and analytical properties of frequency dependence of permeability. Another constraint concerning the bandwidth of electromagnetic wave absorbers follows from the Kramers-Kronig relations for the reflection coefficient. The constraints are of importance in design and analysis of electromagnetic wave absorbers and other devices that employ the microwave magnetic properties of composites, such as

  11. High Energy Single Frequency Resonant Amplifier Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase I project proposes a single frequency high energy resonant amplifier for remote sensing. Current state-of-art technologies can not provide all...

  12. Overview of the Advanced High Frequency Branch

    Science.gov (United States)

    Miranda, Felix A.

    2015-01-01

    This presentation provides an overview of the competencies, selected areas of research and technology development activities, and current external collaborative efforts of the NASA Glenn Research Center's Advanced High Frequency Branch.

  13. Factors Affecting the Benefits of High-Frequency Amplification

    Science.gov (United States)

    Horwitz, Amy R.; Ahlstrom, Jayne B.; Dubno, Judy R.

    2008-01-01

    Purpose: This study was designed to determine the extent to which high-frequency amplification helped or hindered speech recognition as a function of hearing loss, gain-frequency response, and background noise. Method: Speech recognition was measured monaurally under headphones for nonsense syllables low-pass filtered in one-third-octave steps…

  14. On the synthesis of multiple frequency tone burst stimuli for efficient high frequency auditory brainstem response.

    Science.gov (United States)

    Ellingson, Roger M; Dille, Marilyn L; Leek, Marjorie R; Fausti, Stephen A

    2008-01-01

    The development and digital waveform synthesis of a multiple-frequency tone-burst (MFTB) stimulus is presented. The stimulus is designed to improve the efficiency of monitoring high-frequency auditory-brainstem-response (ABR) hearing thresholds. The pure-tone-based, fractional-octave-bandwidth MFTB supports frequency selective ABR audiometry with a bandwidth that falls between the conventional click and single-frequency tone-burst stimuli. The MFTB is being used to identify high frequency hearing threshold change due to ototoxic medication which most generally starts at the ultra-highest hearing frequencies and progresses downwards but could be useful in general limited-bandwidth testing applications. Included is a Mathcad implementation and analysis of our MFTB synthesis technique and sample performance measurements of the MFTB stimulus configuration used in a clinical research ABR system.

  15. Probing High Frequency Noise with Macroscopic Resonant Tunneling

    OpenAIRE

    Lanting, T.; Amin, M. H. S.; Johnson, M. W.; Altomare, F.; Berkley, A. J.; Gildert, S.; Harris, R; Johansson, J; Bunyk, P.; Ladizinsky, E.; Tolkacheva, E.; Averin, D. V.

    2011-01-01

    We have developed a method for extracting the high-frequency noise spectral density of an rf-SQUID flux qubit from macroscopic resonant tunneling (MRT) rate measurements. The extracted noise spectral density is consistent with that of an ohmic environment up to frequencies ~ 4 GHz. We have also derived an expression for the MRT lineshape expected for a noise spectral density consisting of such a broadband ohmic component and an additional strongly peaked low-frequency component. This hybrid m...

  16. High frequency conductivity in carbon nanotubes

    Directory of Open Access Journals (Sweden)

    S. S. Abukari

    2012-12-01

    Full Text Available We report on theoretical analysis of high frequency conductivity in carbon nanotubes. Using the kinetic equation with constant relaxation time, an analytical expression for the complex conductivity is obtained. The real part of the complex conductivity is initially negative at zero frequency and become more negative with increasing frequency, until it reaches a resonance minimum at ω ∼ ωB for metallic zigzag CNs and ω < ωB for armchair CNs. This resonance enhancement is indicative for terahertz gain without the formation of current instabilities induced by negative dc conductivity. We noted that due to the high density of states of conduction electrons in metallic zigzag carbon nanotubes and the specific dispersion law inherent in hexagonal crystalline structure result in a uniquely high frequency conductivity than the corresponding values for metallic armchair carbon nanotubes. We suggest that this phenomenon can be used to suppress current instabilities that are normally associated with a negative dc differential conductivity.

  17. Absolute atomic oxygen and nitrogen densities in radio-frequency driven atmospheric pressure cold plasmas: Synchrotron vacuum ultra-violet high-resolution Fourier-transform absorption measurements

    Energy Technology Data Exchange (ETDEWEB)

    Niemi, K.; O' Connell, D.; Gans, T. [York Plasma Institute, Department of Physics, University of York, York YO10 5DD (United Kingdom); Oliveira, N. de; Joyeux, D.; Nahon, L. [Synchrotron Soleil, l' Orme des Merisiers, St. Aubin BP 48, 91192 Gif sur Yvette Cedex (France); Booth, J. P. [Laboratoire de Physique des Plasmas-CNRS, Ecole Polytechnique, 91128 Palaiseau (France)

    2013-07-15

    Reactive atomic species play a key role in emerging cold atmospheric pressure plasma applications, in particular, in plasma medicine. Absolute densities of atomic oxygen and atomic nitrogen were measured in a radio-frequency driven non-equilibrium plasma operated at atmospheric pressure using vacuum ultra-violet (VUV) absorption spectroscopy. The experiment was conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Measurements were carried out in plasmas operated in helium with air-like N{sub 2}/O{sub 2} (4:1) admixtures. A maximum in the O-atom concentration of (9.1 {+-} 0.7) Multiplication-Sign 10{sup 20} m{sup -3} was found at admixtures of 0.35 vol. %, while the N-atom concentration exhibits a maximum of (5.7 {+-} 0.4) Multiplication-Sign 10{sup 19} m{sup -3} at 0.1 vol. %.

  18. Measurements on polar liquids at a microwave frequency ...

    Indian Academy of Sciences (India)

    A simple method of estimating the dipole moment () and relaxation time () of polar molecules in liquid state, from a single set of dielectric measurements at high frequency, is proposed by using the concept of dielectric virial coefficients and employing Onsager model. The proposed method is tested in a number of polar ...

  19. Noise Measurement and Frequency Analysis of Commercially Available Noisy Toys

    Directory of Open Access Journals (Sweden)

    Shohreh Jalaie

    2005-06-01

    Full Text Available Objective: Noise measurement and frequency analysis of commercially available noisy toys were the main purposes of the study. Materials and Methods: 181 noisy toys commonly found in toy stores in different zones of Tehran were selected and categorized into 10 groups. Noise measurement were done at 2, 25, and 50 cm from toys in dBA. The noisiest toy of each group was frequency analyzed in octave bands. Results: The highest and the lowest intensity levels belonged to the gun (mean=112 dBA and range of 100-127 dBA and to the rattle-box (mean=84 dBA and range of 74-95 dBA, respectively. Noise intensity levels significantly decreased with increasing distance except for two toys. Noise frequency analysis indicated energy in effective hearing frequencies. Most of the toys energies were in the middle and high frequency region. Conclusion: As intensity level of the toys is considerable, mostly more than 90 dBA, and also their energy exist in the middle and high frequency region, toys should be considered as a cause of the hearing impairment.

  20. Novel high-frequency air transducers

    Science.gov (United States)

    Schiller, S.; Hsieh, C.-K.; Chou, C.-H.; Khuri-Yakub, B. T.

    The properties of ligneous materials have been evaluated in order to improve the insertion loss and bandwidth of air-based ultrasonic transducers. It is found that cork and balsa wood have the appropriate impedance to match with air, though their attenuation coefficients are prohibitive for high-frequency operation. For multiple matching layer devices, ligneous materials could be made useful in the 1-10 MHz frequency range.

  1. Frequency Estimation Techniques For High Dynamic Trajectories

    Science.gov (United States)

    Vilnrotter, V. A.; Hinedi, S. M.; Kumar, R.

    1989-01-01

    Report presents comparative study of four techniques for estimating frequency of sinusoidal signal received in presence of noise when transmitter and/or receiver experiencing very high dynamics. Four techniques involve approximate-maximum-likelihood estimator, extended Kalman filter, cross-product automatic frequency control loop, and digital phase locked loop, respectively. In numerical simulations, each technique applied to signal from transmitter maneuvering along common trajectory; performance of each examined to determine its useful operating range, and performances compared.

  2. FREQUENCY-DEPENDENT DISPERSION MEASURES AND IMPLICATIONS FOR PULSAR TIMING

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, J. M. [Astronomy Department, Cornell University, Ithaca, NY 14853 (United States); Shannon, R. M. [CSIRO Astronomy and Space Science, Box 76, Epping, NSW 1710 (Australia); Stinebring, D. R., E-mail: cordes@astro.cornell.edu, E-mail: ryan.shannon@csiro.au, E-mail: dan.stinebring@oberlin.edu [Department of Physics and Astronomy, Oberlin College, Oberlin, OH 44074 (United States)

    2016-01-20

    The dispersion measure (DM), the column density of free electrons to a pulsar, is shown to be frequency dependent because of multipath scattering from small-scale electron-density fluctuations. DMs vary between propagation paths whose transverse extent varies strongly with frequency, yielding arrival times that deviate from the high-frequency scaling expected for a cold, uniform, unmagnetized plasma (1/frequency{sup 2}). Scaling laws for thin phase screens are verified with simulations; extended media are also analyzed. The rms DM difference across an octave band near 1.5 GHz is ∼ 4 × 10{sup −5} pc cm{sup −3} for pulsars at ∼1 kpc distance. The corresponding arrival-time variations are a few to hundreds of nanoseconds for DM ≲ 30 pc cm{sup −3} but increase rapidly to microseconds or more for larger DMs and wider frequency ranges. Chromatic DMs introduce correlated noise into timing residuals with a power spectrum of “low pass” form. The correlation time is roughly the geometric mean of the refraction times for the highest and lowest radio frequencies used, ranging from days to years, depending on the pulsar. We discuss implications for methodologies that use large frequency separations or wide bandwidth receivers for timing measurements. Chromatic DMs are partially mitigable by including an additional chromatic term in arrival time models. Without mitigation, an additional term in the noise model for pulsar timing is implied. In combination with measurement errors from radiometer noise, an arbitrarily large increase in total frequency range (or bandwidth) will yield diminishing benefits and may be detrimental to overall timing precision.

  3. High frequency and pulse scattering physical acoustics

    CERN Document Server

    Pierce, Allan D

    1992-01-01

    High Frequency and Pulse Scattering investigates high frequency and pulse scattering, with emphasis on the phenomenon of echoes from objects. Geometrical and catastrophe optics methods in scattering are discussed, along with the scattering of sound pulses and the ringing of target resonances. Caustics and associated diffraction catastrophes are also examined.Comprised of two chapters, this volume begins with a detailed account of geometrically based approximation methods in scattering theory, focusing on waves transmitted through fluid and elastic scatterers and glory scattering; surface ray r

  4. High-frequency fluctuation measurements by far-infrared laser Faraday-effect polarimetry-interferometry and forward scattering system on MST.

    Science.gov (United States)

    Ding, W X; Lin, L; Duff, J R; Brower, D L

    2014-11-01

    Magnetic fluctuation-induced transport driven by global tearing modes has been measured by Faraday-effect polarimetry and interferometry (phase measurements) in the MST reversed field pinch. However, the role of small-scale broadband magnetic and density turbulence in transport remains unknown. In order to investigate broadband magnetic turbulence, we plan to upgrade the existing detector system by using planar-diode fundamental waveguide mixers optimized for high sensitivity. Initial tests indicate these mixers have ×10 sensitivity improvement compared to currently employed corner-cube Schottky-diode mixers and ×5 lower noise. Compact mixer design will allow us to resolve the wavenumbers up to k ∼ 1-2 cm(-1) for beam width w = 1.5 cm and 15 cm(-1) for beam width w = 2 mm. The system can also be used to measure the scattered signal (amplitude measurement) induced by both plasma density and magnetic fluctuations.

  5. Advances in Very High Frequency Power Conversion

    DEFF Research Database (Denmark)

    Kovacevic, Milovan

    . Excellent performance and small size of magnetic components and capacitors at very high frequencies, along with constant advances in performance of power semiconductor devices, suggests a sizable shift in consumer power supplies market into this area in the near future. To operate dc-dc converter power...... devices at very high frequencies, switching loss needs to reduced or eliminated, as it would become prohibitively large. In addition, as the frequency increases, hard-switched gate driving becomes less and less of an option, as it embodies the same loss mechanism. A low-loss gate drive methods may need...... drive solution, which is applicable in cases when there are at least two power stages, and with minimal additional hardware requirements. It is experimentally confirmed that the method is suitable for both parallel and serial input configurations. Compared to state-of-the-art solutions, the proposed...

  6. Seabed Scattering from Low Frequency Reverberation Measurements

    Science.gov (United States)

    2015-09-30

    SAX99” (sediment acoustics experiments) was con- ducted in the Gulf of Mexico (referred to as SAX99 site).13,14 During the SAX99 experiment, the Biot...frequency dependence ð/ f 2:000Þ, are both readily uniquely determined. The result- ant cs and as as a function of frequency are shown in Figs. 2(a) and

  7. Breakfast frequency among adolescents: associations with measures of family functioning.

    Science.gov (United States)

    Pedersen, Trine Pagh; Holstein, Bjørn E; Damsgaard, Mogens Trab; Rasmussen, Mette

    2016-06-01

    To investigate (i) associations between adolescents' frequency of breakfast and family functioning (close relations to parents, quality of family communication and family support) and (ii) if any observed associations between breakfast frequency and family functioning vary by sociodemographic factors. School-based cross-sectional study. Students completed a web-based questionnaire. Associations were estimated by multilevel multivariate logistic regression. Danish arm of the Health Behaviour in School-aged Children study, 2014. Adolescents aged 13 and 15 years (n 3054) from a random sample of forty-one schools. Nearly one-quarter of the adolescents had low breakfast frequency. Low breakfast frequency was associated with low family functioning measured by three dimensions. The OR (95 % CI) of low breakfast frequency was 1·81 (1·40, 2·33) for adolescents who reported no close relations to parents, 2·28 (1·61, 3·22) for adolescents who reported low level of quality of family communication and 2·09 (1·39, 3·15) for adolescents who reported low level of family support. Joint effect analyses suggested that the odds of low breakfast frequency among adolescents with low family functioning compared with high family functioning were highest among adolescents being girls, immigrants and living in other than a traditional family structure. Low breakfast frequency was associated with low family functioning measured by close relations to parents, quality of family communication and family support. Further, analyses suggested that the associations were more pronounced among girls, immigrants and adolescents from other family structure than traditional. The study highlights the importance of the family setting in promoting regular breakfast frequency among adolescents.

  8. A mobile and self-sufficient lab for high frequency measurements of stable water isotopes and chemistry of multiple water sources

    Science.gov (United States)

    Windhorst, David; Kraft, Philipp; Holly, Hartmut; Sahraei, Amir; Breuer, Lutz

    2017-04-01

    Technical advances over the last years have made instruments for stable water isotope and water chemistry measurements smaller, more durable and energy efficient. It is nowadays feasible to deploy such instruments in situ during field campaigns. Coupled to an automated sample delivery system, high temporal resolution online measurements of various sources are within the bounds of economic and technical possibility. However, the day to day operation of such equipment still requires either a lot of man power and infrastructure or the implementation of a quasi-self-sufficient system. The challenge remains on how to facilitate and remotely operate such a system. We present the design and implementation of the Water Analysis Trailer for Environmental Research (WATER), an autonomous platform consisting of instruments for stable water isotope and water chemistry analysis. The system takes and measures samples in high temporal resolution (self-sufficient power supply, - automated sample delivery and preparation, and - autonomous measurements and management interfacing all instruments. In addition to the basic requirements we implemented: - communication of all system states, alarm messages and measurement results to an internal as well as an external database via cellular telemetry, - automated storage of up to 300 frozen reference samples (100 mL, stored at -18°C), - climate control for temperature sensitive equipment (±1°C), - a local and remote (up to 20 km using radio telemetry) sensor network (i.e. to record states of the hydrological system and climate and soil conditions), also suitable to trigger specific measurements - automatic fire suppression and security system. The initial instrumentation includes a UV spectrometer (ProPs, Trios GmBH, Germany) to measure NO3-, COD, TOC and total suspended sediments, multiparameter water quality probe (YSI600R, YSI, USA) to measure electrical conductivity and pH, and a stable water isotope analyzer (L2130-i, Picarro, USA

  9. Dielectric properties of Nb-doped CaCu{sub 3}Ti{sub 4}O{sub 12} electroceramics measured at high frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Sulaiman, Muhammad Azwadi [School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang (Malaysia); Hutagalung, Sabar D., E-mail: mrsabar@eng.usm.m [School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang (Malaysia); Ain, Mohd Fadzil [School of Electrical and Electronic Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang (Malaysia); Ahmad, Zainal A. [School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang (Malaysia)

    2010-03-18

    In this work, Nb dopant was introduced into CaCu{sub 3}Ti{sub 4}O{sub 12} (CCTO) electroceramic in order to improve the dielectric properties. The CCTO electroceramic was prepared using the solid state reaction method. An X-ray diffractometer (XRD) analysis proved the formation of a single CCTO phase after sintering at 1040 {sup o}C for 10 h. Abnormal grain growth was observed in undoped CCTO and 1 mol% Nb-doped CCTO. Normal grain growth was produced at Nb dopant levels higher than 3 mol%. Dielectric properties were measured at a frequency range of 1 MHz to 1 GHz. It was found that CCTO doped with 1 mol% Nb gave the highest dielectric constant of 18,000 at 1 MHz. Meanwhile, the lowest dielectric loss (0.31) at 1 MHz was given by CCTO doped with 10 mol% Nb. The dielectric constant between 10 MHz and 1 GHz was almost stable with values at around 500.

  10. Measurement of frequency sweep nonlinearity using atomic absorption spectroscopy

    Science.gov (United States)

    Song, Ningfang; Lu, Xiangxiang; Xu, Xiaobin; Pan, Xiong; Li, Wei; Hu, Di; Liu, Jixun

    2018-01-01

    A novel scheme to determine frequency sweep nonlinearity using atomic saturated absorption spectroscopy is proposed and demonstrated. The frequency modulation rate is determined by directly measuring the interference fringe number and the frequency gap between two atomic transition peaks of rubidium atom. An experimental setup is established, and test results show that the frequency sweep nonlinearity is ∼10%, with an average frequency modulation rate of ∼1.12 THz/s. Moreover, the absolute optical frequency and optical path difference between two laser beams are simultaneously determined with this method. This low-cost technique can be used for optical frequency sweep nonlinearity correction and real-time frequency monitor.

  11. High Frequency Amplitude Detector for GMI Magnetic Sensors

    Directory of Open Access Journals (Sweden)

    Aktham Asfour

    2014-12-01

    Full Text Available A new concept of a high-frequency amplitude detector and demodulator for Giant-Magneto-Impedance (GMI sensors is presented. This concept combines a half wave rectifier, with outstanding capabilities and high speed, and a feedback approach that ensures the amplitude detection with easily adjustable gain. The developed detector is capable of measuring high-frequency and very low amplitude signals without the use of diode-based active rectifiers or analog multipliers. The performances of this detector are addressed throughout the paper. The full circuitry of the design is given, together with a comprehensive theoretical study of the concept and experimental validation. The detector has been used for the amplitude measurement of both single frequency and pulsed signals and for the demodulation of amplitude-modulated signals. It has also been successfully integrated in a GMI sensor prototype. Magnetic field and electrical current measurements in open- and closed-loop of this sensor have also been conducted.

  12. High-Order Frequency-Locked Loops

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In very recent years, some attempts for designing high-order frequency-locked loops (FLLs) have been made. Nevertheless, the advantages and disadvantages of these structures, particularly in comparison with a standard FLL and high-order phase-locked loops (PLLs), are rather unclear. This lack...... study, and its small-signal modeling, stability analysis, and parameter tuning are presented. Finally, to gain insight about advantages and disadvantages of high-order FLLs, a theoretical and experimental performance comparison between the designed second-order FLL and a standard FLL (first-order FLL...

  13. Prestress Force Identification for Externally Prestressed Concrete Beam Based on Frequency Equation and Measured Frequencies

    OpenAIRE

    Luning Shi; Haoxiang He; Weiming Yan

    2014-01-01

    A prestress force identification method for externally prestressed concrete uniform beam based on the frequency equation and the measured frequencies is developed. For the purpose of the prestress force identification accuracy, we first look for the appropriate method to solve the free vibration equation of externally prestressed concrete beam and then combine the measured frequencies with frequency equation to identify the prestress force. To obtain the exact solution of the free vibration e...

  14. High Temperature, High Frequency Fuel Metering Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Active Signal Technologies and its subcontractor Moog propose to develop a high-frequency actuator driven valve intended to achieve TRL 6 by the end of Phase II....

  15. High frequency impedances in European XFEL

    Energy Technology Data Exchange (ETDEWEB)

    Dohlus, Martin; Zagorodnov, Igor; Zagorodnova, Olga

    2010-06-15

    The method of the optical approximation is used to estimate the high frequency impedances of different vacuum chamber transitions of the European XFEL beam line. The approximations of the longitudinal impedances are obtained in terms of simple one-dimensional integrals. The transverse impedances are written in analytical closed form. The analytical results are compared with the results obtained by numerical solution of Maxwell's equations. (orig.)

  16. High-Frequency Percussive Ventilation Revisited

    Science.gov (United States)

    2010-01-01

    Landstuhl Regional Medical Center, Germany; and †United States Army Institute of Surgical Research, Fort Sam Houston, Texas. The author does not have...AND ADDRESS(ES) United States Army Institute of Surgical Research, JBSA Fort Sam Houston, TX 8. PERFORMING ORGANIZATION REPORT NUMBER 9...Engl J Med 1981;305:1375–9. 25. Pillow JJ. High-frequency oscillatory ventilation: mecha- nisms of gas exchange and lung mechanics. Crit Care Med

  17. High Frequency Components in Bottlenose Dolphin Echolocation Signals

    National Research Council Canada - National Science Library

    Toland, Ronald

    1998-01-01

    .... To assess the importance of these high frequencies in dolphin echolocation and target identification, experiments were performed in which an acoustic filter, used to suppress the high frequencies...

  18. Measuring Auditory Selective Attention using Frequency Tagging

    Directory of Open Access Journals (Sweden)

    Hari M Bharadwaj

    2014-02-01

    Full Text Available Frequency tagging of sensory inputs (presenting stimuli that fluctuate periodically at rates to which the cortex can phase lock has been used to study attentional modulation of neural responses to inputs in different sensory modalities. For visual inputs, the visual steady-state response (VSSR at the frequency modulating an attended object is enhanced, while the VSSR to a distracting object is suppressed. In contrast, the effect of attention on the auditory steady-state response (ASSR is inconsistent across studies. However, most auditory studies analyzed results at the sensor level or used only a small number of equivalent current dipoles to fit cortical responses. In addition, most studies of auditory spatial attention used dichotic stimuli (independent signals at the ears rather than more natural, binaural stimuli. Here, we asked whether these methodological choices help explain discrepant results. Listeners attended to one of two competing speech streams, one simulated from the left and one from the right, that were modulated at different frequencies. Using distributed source modeling of magnetoencephalography results, we estimate how spatially directed attention modulates the ASSR in neural regions across the whole brain. Attention enhances the ASSR power at the frequency of the attended stream in the contralateral auditory cortex. The attended-stream modulation frequency also drives phase-locked responses in the left (but not right precentral sulcus (lPCS, a region implicated in control of eye gaze and visual spatial attention. Importantly, this region shows no phase locking to the distracting stream suggesting that the lPCS in engaged in an attention-specific manner. Modeling results that take account of the geometry and phases of the cortical sources phase locked to the two streams (including hemispheric asymmetry of lPCS activity help partly explain why past ASSR studies of auditory spatial attention yield seemingly contradictory

  19. Probing high-frequency noise with macroscopic resonant tunneling

    Science.gov (United States)

    Lanting, T.; Amin, M. H. S.; Johnson, M. W.; Altomare, F.; Berkley, A. J.; Gildert, S.; Harris, R.; Johansson, J.; Bunyk, P.; Ladizinsky, E.; Tolkacheva, E.; Averin, D. V.

    2011-05-01

    We have developed a method for extracting the high-frequency noise spectral density of an rf-SQUID flux qubit from macroscopic resonant tunneling (MRT) rate measurements. The extracted noise spectral density is consistent with that of an ohmic environment up to frequencies ~4 GHz. We have also derived an expression for the MRT line shape expected for a noise spectral density consisting of such a broadband ohmic component and an additional strongly peaked low-frequency component. This hybrid model provides an excellent fit to experimental data across a range of tunneling amplitudes and temperatures.

  20. Parametric nanomechanical amplification at very high frequency.

    Science.gov (United States)

    Karabalin, R B; Feng, X L; Roukes, M L

    2009-09-01

    Parametric resonance and amplification are important in both fundamental physics and technological applications. Here we report very high frequency (VHF) parametric resonators and mechanical-domain amplifiers based on nanoelectromechanical systems (NEMS). Compound mechanical nanostructures patterned by multilayer, top-down nanofabrication are read out by a novel scheme that parametrically modulates longitudinal stress in doubly clamped beam NEMS resonators. Parametric pumping and signal amplification are demonstrated for VHF resonators up to approximately 130 MHz and provide useful enhancement of both resonance signal amplitude and quality factor. We find that Joule heating and reduced thermal conductance in these nanostructures ultimately impose an upper limit to device performance. We develop a theoretical model to account for both the parametric response and nonequilibrium thermal transport in these composite nanostructures. The results closely conform to our experimental observations, elucidate the frequency and threshold-voltage scaling in parametric VHF NEMS resonators and sensors, and establish the ultimate sensitivity limits of this approach.

  1. High frequency image-based flow detection

    Energy Technology Data Exchange (ETDEWEB)

    Chung, R [National Heart and Lung Institute, Royal Brompton Hospital, London SW3 6NP (United Kingdom); Prager, R W [Dept. of Engineering, University of Cambridge, Cambridge CB2 1PZ (United Kingdom); Gee, A H [Dept. of Engineering, University of Cambridge, Cambridge CB2 1PZ (United Kingdom); Treece, G M [Dept. of Engineering, University of Cambridge, Cambridge CB2 1PZ (United Kingdom)

    2004-01-01

    Tumour angiogenesis refers to neovascular development on a microvascular scale and is an early indicator of cancer. Prototype high frequency pulsed Doppler systems using 50 MHz transducers have been reported to detect microvascular flow in vessels 0.02 mm to 0.5 mm in diameter at superficial depths of 0.5 mm. Detecting flow in microvasculature at deeper depths requires lower frequency transducers with a resulting tradeoff in spatial resolution. Using a 22 MHz transducer, we demonstrate a speckle decorrelation technique to detect in vitro flow in soft tubing of 0.5 mm diameter at a depth of 2 cm. This image-based decorrelation technique is capable of detecting flow in significantly narrower diameters down to 0.125 mm by decreasing the region of interest.

  2. Asynchronous BCI control using high-frequency SSVEP

    National Research Council Canada - National Science Library

    Diez, Pablo F; Mut, Vicente A; Avila Perona, Enrique M; Laciar Leber, Eric

    2011-01-01

    ...) and high frequency (> 30 Hz). SSVEP-based Brain-Computer Interfaces (BCI) are principally focused on the low and medium range of frequencies whereas there are only a few projects in the high-frequency range...

  3. High-power femtosecond Raman frequency shifter.

    Science.gov (United States)

    Vicario, Carlo; Shalaby, Mostafa; Konyashchenko, Aleksandr; Losev, Leonid; Hauri, Christoph P

    2016-10-15

    We report on the generation of broadband, high-energy femtosecond pulses centered at 1.28 μm by stimulated Raman scattering in a pressurized hydrogen cell. Stimulated Raman scattering is performed by two chirped and delayed pulses originating from a multi-mJ Ti:sapphire amplifier. The Stokes pulse carries record-high energy of 4.4 mJ and is recompressed down to 66 fs by a reflective grating pair. We characterized the short-wavelength mid-infrared source in view of energy stability, beam profile, and conversion efficiency at repetition rates of 100 and 10 Hz. The demonstrated high-energy frequency shifter will benefit intense THz sources based on highly nonlinear organic crystals.

  4. Frequencies of inaudible high-frequency sounds differentially affect brain activity: positive and negative hypersonic effects.

    Directory of Open Access Journals (Sweden)

    Ariko Fukushima

    Full Text Available The hypersonic effect is a phenomenon in which sounds containing significant quantities of non-stationary high-frequency components (HFCs above the human audible range (max. 20 kHz activate the midbrain and diencephalon and evoke various physiological, psychological and behavioral responses. Yet important issues remain unverified, especially the relationship existing between the frequency of HFCs and the emergence of the hypersonic effect. In this study, to investigate the relationship between the hypersonic effect and HFC frequencies, we divided an HFC (above 16 kHz of recorded gamelan music into 12 band components and applied them to subjects along with an audible component (below 16 kHz to observe changes in the alpha2 frequency component (10-13 Hz of spontaneous EEGs measured from centro-parieto-occipital regions (Alpha-2 EEG, which we previously reported as an index of the hypersonic effect. Our results showed reciprocal directional changes in Alpha-2 EEGs depending on the frequency of the HFCs presented with audible low-frequency component (LFC. When an HFC above approximately 32 kHz was applied, Alpha-2 EEG increased significantly compared to when only audible sound was applied (positive hypersonic effect, while, when an HFC below approximately 32 kHz was applied, the Alpha-2 EEG decreased (negative hypersonic effect. These findings suggest that the emergence of the hypersonic effect depends on the frequencies of inaudible HFC.

  5. Direct precision frequency measurement and correction technology with double ADC

    Science.gov (United States)

    Bai, L. N.; Liu, H. D.; Wang, T. T.; Ge, X. X.; Zhai, H. Q.; Zhou, W.

    2017-12-01

    A new method of direct precision frequency measurement is proposed in this paper, which uses the clock cursor effect between the sampling clock signal and input signal and ADC (analog to digital converter) quantization error suppression technique in the background of digital measurement with double ADC. On this basis, a precision frequency corrector is designed. Compared with the traditional frequency synthesizer, this device takes the non-standard frequency signal of the crystal oscillator as the reference to realize the standard frequency signal output through the frequency correction function. Meanwhile, the output signal is obviously narrower in range, from 0.0001 Hz to 0.1 Hz. The frequency corrector can also realize the second stability of less than 3 × 10-12 and a small frequency correction of 10-11 orders of magnitude.

  6. Cultures of High-frequency Trading

    DEFF Research Database (Denmark)

    Lange, Ann-Christina; Lenglet, Marc; Seyfert, Robert

    2016-01-01

    As part of ongoing work to lay a foundation for social studies of high-frequency trading (HFT), this paper introduces the culture(s) of HFT as a sociological problem relating to knowledge and practice. HFT is often discussed as a purely technological development, where all that matters is the speed...... of allocating, processing and transmitting data. Indeed, the speed at which trades are executed and data transmitted is accelerating, and it is fair to say that algorithms are now the primary interacting agents operating in the financial markets. However, we contend that HFT is first and foremost a cultural...

  7. A simple, tunable, and highly sensitive radio-frequency sensor.

    Science.gov (United States)

    Cui, Yan; Sun, Jiwei; He, Yuxi; Wang, Zheng; Wang, Pingshan

    2013-08-05

    We report a radio frequency (RF) sensor that exploits tunable attenuators and phase shifters to achieve high-sensitivity and broad band frequency tunability. Three frequency bands are combined to enable sensor operations from ∼20 MHz to ∼38 GHz. The effective quality factor (Qeff ) of the sensor is as high as ∼3.8 × 10(6) with 200 μl of water samples. We also demonstrate the measurement of 2-proponal-water-solution permittivity at 0.01 mole concentration level from ∼1 GHz to ∼10 GHz. Methanol-water solution and de-ionized water are used to calibrate the RF sensor for the quantitative measurements.

  8. Design and development of ITER high-frequency magnetic sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Y., E-mail: Yunxing.Ma@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Fircroft Engineering, Lingley House, 120 Birchwood Point, Birchwood Boulevard, Warrington, WA3 7QH (United Kingdom); Vayakis, G. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Begrambekov, L.B. [National Research Nuclear University (MEPhI), 115409, Moscow, Kashirskoe shosse 31 (Russian Federation); Cooper, J.-J. [Culham Centre for Fusion Energy (CCFE), Abingdon, Oxfordshire OX14 3DB (United Kingdom); Duran, I. [IPP Prague, Za Slovankou 1782/3, 182 00 Prague 8 (Czech Republic); Hirsch, M.; Laqua, H.P. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Moreau, Ph. [CEA Cadarache, 13108 Saint Paul lez Durance Cedex (France); Oosterbeek, J.W. [Eindhoven University of Technology (TU/e), PO Box 513, 5600 MB Eindhoven (Netherlands); Spuig, P. [CEA Cadarache, 13108 Saint Paul lez Durance Cedex (France); Stange, T. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Walsh, M. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-15

    Highlights: • ITER high-frequency magnetic sensor system has been designed. • Prototypes have been successfully manufactured. • Manufactured prototypes have been tested in various labs. • Test results experimentally validated the design. - Abstract: High-frequency (HF) inductive magnetic sensors are the primary ITER diagnostic set for Toroidal Alfvén Eigenmodes (TAE) detection, while they also supplement low-frequency MHD and plasma equilibrium measurements. These sensors will be installed on the inner surface of ITER vacuum vessel, operated in a harsh environment with considerable neutron/nuclear radiation and high thermal load. Essential components of the HF sensor system, including inductive coil, electron cyclotron heating (ECH) shield, electrical cabling and termination load, have been designed to meet ITER measurement requirements. System performance (e.g. frequency response, thermal conduction) has been assessed. A prototyping campaign was initiated to demonstrate the manufacturability of the designed components. Prototypes have been produced according to the specifications. A series of lab tests have been performed to examine assembly issues and validate electrical and thermo-mechanical aspects of the design. In-situ microwave radiation test has been conducted in the MISTRAL test facility at IPP-Greifswald to experimentally examine the microwave shielding efficiency and structural integrity of the ECH shield. Low-power microwave attenuation measurement and scanning electron microscopic inspection were conducted to probe and examine the quality of the metal coating on the ECH shield.

  9. Bite frequency measured by head pitch movements in grazing experiment

    DEFF Research Database (Denmark)

    Oudshoorn, Frank W.; S. Nadimi, Esmaeil; Jørgensen, Rasmus Nyholm

    2010-01-01

    Objective of the experiment was to investigate if bite frequency could be measured by registering head movements in the field. Background for this research question was the found variation of bite frequency measured on different initial grass length (Oudshoorn & Nadimi, 2008) as also documented...... bite frequency variation related to grass length and grass quality (Pulido & Leaver 2001; Barrett et al. 2003). .   Head movements and bite frequency were registered in spring and autumn in 2009, with 2x10 cows grazing two weeks in two stocking densities.  Head movements were measured by activity...... sensors placed on the head of the cows, bite frequency was registered manually by noting the rip off sound during a specified time bout. Sward registrations comprised grass length measurement by rising plate meter , grass quality by laboratory analysis of hand harvested grass simulating the cows grazing...

  10. High-frequency microrheology reveals cytoskeleton dynamics in living cells

    Science.gov (United States)

    Rigato, Annafrancesca; Miyagi, Atsushi; Scheuring, Simon; Rico, Felix

    2017-08-01

    Living cells are viscoelastic materials, dominated by an elastic response on timescales longer than a millisecond. On shorter timescales, the dynamics of individual cytoskeleton filaments are expected to emerge, but active microrheology measurements on cells accessing this regime are scarce. Here, we develop high-frequency microrheology experiments to probe the viscoelastic response of living cells from 1 Hz to 100 kHz. We report the viscoelasticity of different cell types under cytoskeletal drug treatments. On previously inaccessible short timescales, cells exhibit rich viscoelastic responses that depend on the state of the cytoskeleton. Benign and malignant cancer cells revealed remarkably different scaling laws at high frequencies, providing a unique mechanical fingerprint. Microrheology over a wide dynamic range--up to the frequency characterizing the molecular components--provides a mechanistic understanding of cell mechanics.

  11. High temperature measuring device

    Science.gov (United States)

    Tokarz, Richard D.

    1983-01-01

    A temperature measuring device for very high design temperatures (to 2,000.degree. C.). The device comprises a homogenous base structure preferably in the form of a sphere or cylinder. The base structure contains a large number of individual walled cells. The base structure has a decreasing coefficient of elasticity within the temperature range being monitored. A predetermined quantity of inert gas is confined within each cell. The cells are dimensionally stable at the normal working temperature of the device. Increases in gaseous pressure within the cells will permanently deform the cell walls at temperatures within the high temperature range to be measured. Such deformation can be correlated to temperature by calibrating similarly constructed devices under known time and temperature conditions.

  12. A new way to measure the electron cyclotron frequency

    Science.gov (United States)

    Palmer, F. L.

    1993-03-01

    A method is described for using spin flips to measure the 0 to 1 cyclotron transition frequency of a single electron in a Penning trap. Detection can be accomplished with magnetic bottles of 10 T/m2 or less, thereby greatly reducing the thermal broadening of the cyclotron line. This method complements a recently published technique for measuring the anomaly frequency, making a more precise measurement of the electron anomaly ratio possible.

  13. Effect of high-frequency excitation on natural frequencies of spinning discs

    DEFF Research Database (Denmark)

    Hansen, Morten Hartvig

    2000-01-01

    The effect of high-frequency, non-resonant parametric excitation on the low-frequency response of spinning discs is considered. The parametric excitation is obtained through a non-constant rotation speed, where the frequency of the pulsating overlay is much higher than the lowest natural frequenc...

  14. Asynchronous BCI control using high-frequency SSVEP

    Directory of Open Access Journals (Sweden)

    Laciar Leber Eric

    2011-07-01

    Full Text Available Abstract Background Steady-State Visual Evoked Potential (SSVEP is a visual cortical response evoked by repetitive stimuli with a light source flickering at frequencies above 4 Hz and could be classified into three ranges: low (up to 12 Hz, medium (12-30 and high frequency (> 30 Hz. SSVEP-based Brain-Computer Interfaces (BCI are principally focused on the low and medium range of frequencies whereas there are only a few projects in the high-frequency range. However, they only evaluate the performance of different methods to extract SSVEP. Methods This research proposed a high-frequency SSVEP-based asynchronous BCI in order to control the navigation of a mobile object on the screen through a scenario and to reach its final destination. This could help impaired people to navigate a robotic wheelchair. There were three different scenarios with different difficulty levels (easy, medium and difficult. The signal processing method is based on Fourier transform and three EEG measurement channels. Results The research obtained accuracies ranging in classification from 65% to 100% with Information Transfer Rate varying from 9.4 to 45 bits/min. Conclusions Our proposed method allows all subjects participating in the study to control the mobile object and to reach a final target without prior training.

  15. High frequency oscillations and high frequency functional network characteristics in the intraoperative electrocorticogram in epilepsy

    NARCIS (Netherlands)

    Zweiphenning, W. J E M; van 't Klooster, M. A.; van Diessen, E.; van Klink, N. E C; Huiskamp, G. J M; Gebbink, T. A.; Leijten, F. S S; Gosselaar, P. H.; Otte, W. M.; Stam, C. J.; Braun, K. P J; Zijlmans, G. J M

    2016-01-01

    OBJECTIVE: High frequency oscillations (HFOs; > 80 Hz), especially fast ripples (FRs, 250-500 Hz), are novel biomarkers for epileptogenic tissue. The pathophysiology suggests enhanced functional connectivity within FR generating tissue. Our aim was to determine the relation between brain areas

  16. High frequency oscillations and high frequency functional network characteristics in the intraoperative electrocorticogram in epilepsy

    Directory of Open Access Journals (Sweden)

    W.J.E.M. Zweiphenning

    2016-01-01

    Significance: ‘Baseline’ high-frequency network parameters might help intra-operative recognition of epileptogenic tissue without the need for waiting for events. These findings can increase our understanding of the ‘architecture’ of epileptogenic networks and help unravel the pathophysiology of HFOs.

  17. Dream recall frequency: impact of prospective measures and motivational factors.

    Science.gov (United States)

    Zadra, Antonio; Robert, Geneviève

    2012-12-01

    Significant individual differences exist in dream recall frequency (DRF) but some variance is likely attributable to instrument choice in measuring DRF. Three hundred and fifty eight participants estimated their weekly DRF and recorded their dreams in either a narrative log (n = 165) or checklist log (n = 193) for 2-5 weeks. There was an early peak in DRF within the first week of both types of prospective logs after which DRF remained relatively stable. Although the two groups did not differ in their estimated DRF, significantly fewer dreams were reported per week on the narrative logs and only checklist logs yielded significantly higher DRF than participants' questionnaire estimates. The interactions between DRF measures did not vary across groups with low, medium or high baseline levels of DRF. Keeping a dream log does not necessarily increase DRF and narrative logs' time consuming nature can impact subjects' motivation to report all of their dreams over time. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Frequency Combs in the XUV by Intra-Laser High Harmonic Generation for Ultra-Precise Measurements of the Fine Structure Constant

    Science.gov (United States)

    2015-06-03

    diverse as medicine, biology, chemistry , physics and materials science, enabling applications, such as time-resolved ARPES, VUV and XUV metrology, or...multimegahertz VUV/XUV sources with high photon flux would have a strong impact in fields as diverse as medicine, biology, chemistry , physics, and...spectra. Among the different borates, Yb:YCOB and Yb:LSB have the advantage of a nearly congruent melting behavior, which enables Czochral- ski growth

  19. Multiplexed fluorescence lifetime measurements by frequency-sweeping Fourier spectroscopy.

    Science.gov (United States)

    Zhao, Ming; Peng, Leilei

    2010-09-01

    We report simultaneous measurements of fluorescence lifetimes at multiple excitation wavelengths with a Fourier transform frequency domain fluorescence lifetime spectrometer. The spectrometer uses a Michelson interferometer with its differential optical path length scanning at a 22,000 Hz scan rate. The scan speed of the optical delay varies linearly during each scan and creates interference modulations that sweep from -150 to 150 MHz in 45.5 micros. The frequency-sweeping modulation allows nanosecond fluorescence lifetime measurements within 45.5 micros. Because the interference modulation frequency is wavelength dependent, under the Fourier multiplexing principle, the spectrometer can perform lifetime measurements on multiple excitation wavelengths simultaneously.

  20. Electron neutral collision frequency measurement with the hairpin resonator probe

    Science.gov (United States)

    Peterson, David J.; Kraus, Philip; Chua, Thai Cheng; Larson, Lynda; Shannon, Steven C.

    2017-09-01

    Electron neutral collision frequency is measured using both grounded and floating hairpin resonator probes in a 27 MHz parallel plate capacitively coupled plasma. Operating conditions are 0.1-2 Torr (13.3-267 Pa) in Ar, He, and Ar-He gas mixtures. The method treats the hairpin probe as a two wire transmission line immersed in a dielectric medium. Measurements are obtained using a pressure and sheath correction process by sweeping over assumed collision frequencies in order to obtain the measured collision frequency. Results are compared to hybrid plasma equipment module simulations and show good agreement.

  1. Plant Responses to High Frequency Electromagnetic Fields

    Directory of Open Access Journals (Sweden)

    Alain Vian

    2016-01-01

    Full Text Available High frequency nonionizing electromagnetic fields (HF-EMF that are increasingly present in the environment constitute a genuine environmental stimulus able to evoke specific responses in plants that share many similarities with those observed after a stressful treatment. Plants constitute an outstanding model to study such interactions since their architecture (high surface area to volume ratio optimizes their interaction with the environment. In the present review, after identifying the main exposure devices (transverse and gigahertz electromagnetic cells, wave guide, and mode stirred reverberating chamber and general physics laws that govern EMF interactions with plants, we illustrate some of the observed responses after exposure to HF-EMF at the cellular, molecular, and whole plant scale. Indeed, numerous metabolic activities (reactive oxygen species metabolism, α- and β-amylase, Krebs cycle, pentose phosphate pathway, chlorophyll content, terpene emission, etc. are modified, gene expression altered (calmodulin, calcium-dependent protein kinase, and proteinase inhibitor, and growth reduced (stem elongation and dry weight after low power (i.e., nonthermal HF-EMF exposure. These changes occur not only in the tissues directly exposed but also systemically in distant tissues. While the long-term impact of these metabolic changes remains largely unknown, we propose to consider nonionizing HF-EMF radiation as a noninjurious, genuine environmental factor that readily evokes changes in plant metabolism.

  2. Plant Responses to High Frequency Electromagnetic Fields

    Science.gov (United States)

    Vian, Alain; Davies, Eric; Gendraud, Michel; Bonnet, Pierre

    2016-01-01

    High frequency nonionizing electromagnetic fields (HF-EMF) that are increasingly present in the environment constitute a genuine environmental stimulus able to evoke specific responses in plants that share many similarities with those observed after a stressful treatment. Plants constitute an outstanding model to study such interactions since their architecture (high surface area to volume ratio) optimizes their interaction with the environment. In the present review, after identifying the main exposure devices (transverse and gigahertz electromagnetic cells, wave guide, and mode stirred reverberating chamber) and general physics laws that govern EMF interactions with plants, we illustrate some of the observed responses after exposure to HF-EMF at the cellular, molecular, and whole plant scale. Indeed, numerous metabolic activities (reactive oxygen species metabolism, α- and β-amylase, Krebs cycle, pentose phosphate pathway, chlorophyll content, terpene emission, etc.) are modified, gene expression altered (calmodulin, calcium-dependent protein kinase, and proteinase inhibitor), and growth reduced (stem elongation and dry weight) after low power (i.e., nonthermal) HF-EMF exposure. These changes occur not only in the tissues directly exposed but also systemically in distant tissues. While the long-term impact of these metabolic changes remains largely unknown, we propose to consider nonionizing HF-EMF radiation as a noninjurious, genuine environmental factor that readily evokes changes in plant metabolism. PMID:26981524

  3. Compensation of Unavailable Test Frequencies During Immunity Measurements

    Science.gov (United States)

    Gronwald, F.; Kebel, R.; Stadtler, T.

    2012-05-01

    Radiated immunity tests usually are performed in shielded test environments, such as anechoic chambers, GTEM-cells, and mode stirred chambers, for example. Then, if testing is performed in the frequency domain, the corresponding EMC-standards often specify test frequencies that have to be used. These requirements may become incompatible in case of large test objects, such as passenger aircraft, that cannot be placed in shielded test environments but only can be tested in open environments where, for regulatory reasons, not all required test frequencies can be applied. In this contribution it is investigated whether incomplete test procedures due to unavailable test frequencies can be compensated by alternative measurement setups.

  4. DISTRIBUTION OF HIGH-FREQUENCY VOLTAGE IN DISTRIBUTION NETWORK

    Directory of Open Access Journals (Sweden)

    M. I. Polujanov

    2005-01-01

    Full Text Available The paper reveals a method for remote determination of a location of single-phase short circuit on the ground in distribution networks with isolated neutral point. The method is based on measurement of high-frequency (a tone  range inter-phase voltage at all transformer substations and it creates preconditions for automation of searching process.  

  5. On-Chip Terahertz-Frequency Measurements of Liquids.

    Science.gov (United States)

    Swithenbank, Matthew; Burnett, Andrew D; Russell, Christopher; Li, Lianhe H; Davies, Alexander Giles; Linfield, Edmund H; Cunningham, John E; Wood, Christopher D

    2017-08-01

    Terahertz-frequency-range measurements can offer potential insight into the picosecond dynamics, and therefore function, of many chemical systems. There is a need to develop technologies capable of performing such measurements in aqueous and polar environments, particularly when it is necessary to maintain the full functionality of biological samples. In this study, we present a proof-of-concept technology comprising an on-chip planar Goubau line, integrated with a microfluidic channel, which is capable of low-loss, terahertz-frequency-range spectroscopic measurements of liquids. We also introduce a mathematical model that accounts for changes in the electric field distribution around the waveguide, allowing accurate, frequency-dependent liquid parameters to be extracted. We demonstrate the sensitivity of this technique by measuring a homologous alcohol series across the 0.1-0.8 THz frequency range.

  6. Measuring nightmare frequency: retrospective questionnaires versus prospective logs

    NARCIS (Netherlands)

    Lancee, J.; Spoormaker, V.I.; Peterse, G.; Van den Bout, J.

    2008-01-01

    Retrospective measurements underestimate nightmare frequency, but little is known about how retrospective duration and attention for nightmares may affect this process. This study evaluates the differences between two retrospective durations, a prospective log, and a retrospective estimate after

  7. Prestress Force Identification for Externally Prestressed Concrete Beam Based on Frequency Equation and Measured Frequencies

    Directory of Open Access Journals (Sweden)

    Luning Shi

    2014-01-01

    Full Text Available A prestress force identification method for externally prestressed concrete uniform beam based on the frequency equation and the measured frequencies is developed. For the purpose of the prestress force identification accuracy, we first look for the appropriate method to solve the free vibration equation of externally prestressed concrete beam and then combine the measured frequencies with frequency equation to identify the prestress force. To obtain the exact solution of the free vibration equation of multispan externally prestressed concrete beam, an analytical model of externally prestressed concrete beam is set up based on the Bernoulli-Euler beam theory and the function relation between prestress variation and vibration displacement is built. The multispan externally prestressed concrete beam is taken as the multiple single-span beams which must meet the bending moment and rotation angle boundary conditions, the free vibration equation is solved using sublevel simultaneous method and the semi-analytical solution of the free vibration equation which considered the influence of prestress on section rigidity and beam length is obtained. Taking simply supported concrete beam and two-span concrete beam with external tendons as examples, frequency function curves are obtained with the measured frequencies into it and the prestress force can be identified using the abscissa of the crosspoint of frequency functions. Identification value of the prestress force is in good agreement with the test results. The method can accurately identify prestress force of externally prestressed concrete beam and trace the trend of effective prestress force.

  8. Saltating Snow Mechanics: High Frequency Particle Response to Mountain Wind

    Science.gov (United States)

    Aksamit, N. O.; Pomeroy, J. W.

    2015-12-01

    Blowing snow transport theory is currently limited by its dependency on the coupling of time-averaged measurements of particle saltation and suspension and wind speed. Details of the stochastic process of particle transport and complex bed interactions in the saltation layer, along with the influence of boundary-layer turbulence are unobservable with classic measurement techniques. In contrast, recent advances in two-phase sand transport understanding have been spurred by development of high-frequency wind and particle velocity measurement techniques. To advance the understanding of blowing snow, laser illuminated high-speed videography and ultrasonic anemometry were deployed in a mountain environment to examine saltation of snow over a natural snowpack in detail. A saltating snow measurement site was established at the Fortress Mountain Snow Laboratory, Alberta, Canada and instrumented with two Campbell CSAT3 ultrasonic anemometers, four Campbell SR50 ultrasonic snow depth sounders and a two dimensional Particle Tracking Velocimetry (PTV) system. Measurements were collected during nighttime blowing snow events, quantifying snow particle response to high frequency wind gusts. This novel approach permits PTV to step beyond mean statistics of snow transport by identifying sub-species of saltation motion in the first 20 mm above the surface, as well as previously overlooked initiation processes, such as tumbling aggregate snow crystals ejecting smaller grains, then eventually disintegrating and bouncing into entrainment. Spectral characteristics of snow particle ejection and saltation dynamics were also investigated. These unique observations are starting to inform novel conceptualizations of saltating snow transport mechanisms.

  9. Effect of skin dielectric properties on the read range of epidermal ultra-high frequency radio-frequency identification tags.

    Science.gov (United States)

    Oyeka, Dumtoochukwu O; Batchelor, John C; Ziai, Ali Mohamad

    2017-04-01

    This Letter presents an investigation of the effect of human tissue conductivity and permittivity on the performance of epidermal transfer tattoo ultra-high frequency radio-frequency identification (RFID) tags. The measurements were carried out on 20 individuals and the variations in the measured dielectric properties correlate well with variations in the measured tag read range on the individuals and to a lesser extent with their body mass index values. Simulation results also showed the effects of permittivity and conductivity on the designed resonance frequency of the RFID tag.

  10. Effect of skin dielectric properties on the read range of epidermal ultra-high frequency radio-frequency identification tags

    Science.gov (United States)

    Batchelor, John C.; Ziai, Ali Mohamad

    2017-01-01

    This Letter presents an investigation of the effect of human tissue conductivity and permittivity on the performance of epidermal transfer tattoo ultra-high frequency radio-frequency identification (RFID) tags. The measurements were carried out on 20 individuals and the variations in the measured dielectric properties correlate well with variations in the measured tag read range on the individuals and to a lesser extent with their body mass index values. Simulation results also showed the effects of permittivity and conductivity on the designed resonance frequency of the RFID tag. PMID:28461902

  11. A High Power Frequency Doubled Fiber Laser

    Science.gov (United States)

    Thompson, Rob; Tu, Meirong; Aveline, Dave; Lundblad, Nathan; Maleki, Lute

    2003-01-01

    This slide presentation reviews the power frequencies for the doubled fiber laser. It includes information on the 780 nm laser, second harmonic generation in one crystal, cascading crystals, the tenability of laser systems, laser cooling, and directions for future work.

  12. Characterizing Fracture Property Using Resistivity Measured at Different Frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Horne, Roland N. [Stanford Univ., CA (United States); Li, Kewen [Stanford Univ., CA (United States)

    2014-09-30

    The objective was to develop geophysical approaches to detecting and evaluating the fractures created or existing in EGS and other geothermal reservoirs by measuring the resistivity at different frequencies. This project has been divided into two phases: Phase I (first year): Proof of Concept – develop the resistivity approach and verify the effect of frequency on the resistivity in rocks with artificial or natural fractures over a wide range of frequencies. Phase II: Prototyping Part 1 (second year): measure the resistivity in rocks with fractures of different apertures, different length, and different configurations at different frequencies. Part 2 (third year): develop mathematical models and the resistivity method; infer the fracture properties using the measured resistivity data.

  13. High frequency oscillations and high frequency functional network characteristics in the intraoperative electrocorticogram in epilepsy.

    Science.gov (United States)

    Zweiphenning, W J E M; van 't Klooster, M A; van Diessen, E; van Klink, N E C; Huiskamp, G J M; Gebbink, T A; Leijten, F S S; Gosselaar, P H; Otte, W M; Stam, C J; Braun, K P J; Zijlmans, G J M

    2016-01-01

    High frequency oscillations (HFOs; > 80 Hz), especially fast ripples (FRs, 250-500 Hz), are novel biomarkers for epileptogenic tissue. The pathophysiology suggests enhanced functional connectivity within FR generating tissue. Our aim was to determine the relation between brain areas showing FRs and 'baseline' functional connectivity within EEG networks, especially in the high frequency bands. We marked FRs, ripples (80-250 Hz) and spikes in the electrocorticogram of 14 patients with refractory temporal lobe epilepsy. We assessed 'baseline' functional connectivity in epochs free of epileptiform events within these recordings, using the phase lag index. We computed the Eigenvector Centrality (EC) per channel in the FR and gamma band network. We compared EC between channels that did or did not show events at other moments in time. FR-band EC was higher in channels with than without spikes. Gamma-band EC was lower in channels with ripples and FRs. We confirmed previous findings of functional isolation in the gamma-band and found a first proof of functional integration in the FR-band network of channels covering presumed epileptogenic tissue. 'Baseline' high-frequency network parameters might help intra-operative recognition of epileptogenic tissue without the need for waiting for events. These findings can increase our understanding of the 'architecture' of epileptogenic networks and help unravel the pathophysiology of HFOs.

  14. Arctic Climate Forcing Observations to Improve Earth System Models: Measurements at High Frequency, Fine Spatial Resolution, and Climatically Relevant Spatial Scales with the use of the Recently Deployed NGEE-Arctic Tram

    Science.gov (United States)

    Curtis, J. B.; Serbin, S.; Dafflon, B.; Raz Yaseef, N.; Torn, M. S.; Cook, P. J.; Lewin, K. F.; Wullschleger, S. D.

    2014-12-01

    In order to improve the representation of the land surface and subsurface properties and their associated feedbacks with climate forcings, climate change, and drivers in Earth System Models (ESMs), detailed observations need to be made at climatically relevant spatial and temporal scales. Pan-Arctic spatial heterogeneity and temporal variation present major challenges to the current generation of ESMs. To enable highly spatially resolved and high temporal frequency measurements for the independent validation of modeled energy and greenhouse gas surface fluxes at core to intermediate scales, we have developed, tested, and deployed an automated observational platform, the Next Generation Ecosystem Experiment (NGEE)-Arctic Tram. The NGEE-Arctic Tram, installed on the Barrow Environmental Observatory (BEO) near Barrow, AK in mid May 2014, consists of 65 meters of elevated track and a fully automated cart carrying a suite of radiation and remote sensing instrumentation. The tram transect is located within the NGEE eddy covariance tower footprint to help better understand the relative contribution of different landforms (e.g. low center vs high center polygonal tundra and associated vegetation) to the overall energy budget of the footprint. Electrical resistivity tomography (ERT), soil moisture, and soil temperature sensors are acquired autonomously and co-located with the tram to link subsurface properties with surface observations. To complement the high frequency and fine spatial resolution of the tram, during the summer field seasons of 2013 and 2014 a portable version of the NGEE-Arctic Tram (also know as the portable energy pole or PEP); was used to characterize surface albedo, NDVI, surface temperature, and photosynthetically active radiation (PAR) across two ~500 m BEO transects co-located with subsurface ERT and ground penetrating radar (GPR) measurements. In addition, a ~ 3 Km transect across three drained thaw-lake basins (DTLB) of different climate

  15. Distributed measurement of acoustic vibration location with frequency multiplexed phase-OTDR

    Science.gov (United States)

    Iida, Daisuke; Toge, Kunihiro; Manabe, Tetsuya

    2017-07-01

    All-fiber distributed vibration sensing is attracting attention in relation to structural health monitoring because it is cost effective, offers high coverage of the monitored area and can detect various structural problems. And in particular the demand for high-speed vibration sensing operating at more than 10 kHz has increased because high frequency vibration indicates high energy and severe trouble in the monitored object. Optical fiber vibration sensing with phase-sensitive optical time domain reflectometry (phase-OTDR) has long been studied because it can be used for distributed vibration sensing in optical fiber. However, pulse reflectometry such as OTDR cannot measure high-frequency vibration whose cycle is shorter than the repetition time of the OTDR. That is, the maximum detectable frequency depends on fiber length. In this paper, we describe a vibration sensing technique with frequency-multiplexed OTDR that can detect the entire distribution of a high-frequency vibration thus allowing us to locate a high-speed vibration point. We can measure the position, frequency and dynamic change of a high-frequency vibration whose cycle is shorter than the repetition time. Both frequency and position are visualized simultaneously for a 5-km fiber with an 80-kHz frequency response and a 20-m spatial resolution.

  16. High efficiency coupling of radio frequency beams from the dual frequency gyrotron with a corrugated waveguide transmission system.

    Science.gov (United States)

    Oda, Yasuhisa; Kajiwara, Ken; Takahashi, Koji; Mitsunaka, Yoshika; Sakamoto, Keishi

    2013-01-01

    High efficiency coupling of the millimeter-wave output of the dual-frequency gyrotron with the transmission line was demonstrated. The dual-frequency gyrotron was design to produce similar beam profiles for two operation frequencies (170 GHz and 137 GHz). Using two RF beam reflecting mirrors in a matching optics unit (MOU), which are designed to transform the beam profile of the gyrotron output to the fundamental waveguide mode (HE(11) mode) at 170 GHz, high efficiency coupling was demonstrated for two frequencies. The measured mode purity of HE(11) mode was 96% at 170 GHz and 94% at 137 GHz operations with the identical mirrors at the fixed mirror position and angle. The results indicate that the significantly simple dual frequency system is realized by the gyrotron designed to output the similar beam profiles at different frequency operation.

  17. Cross-education after high-frequency versus low-frequency volume-matched handgrip training.

    Science.gov (United States)

    Boyes, Natasha G; Yee, Peter; Lanovaz, Joel L; Farthing, Jonathan P

    2017-10-01

    Cross-education training programs cause interlimb asymmetry of strength and hypertrophy. We examined the cross-education effects from a high-frequency (HF) versus a low-frequency (LF) volume-matched handgrip training program on interlimb asymmetry. Right-handed participants completed either HF (n = 10; 2 × 6 repetitions 10 times per week) or LF (n = 9; 5 × 8 repetitions 3 times per week) training. Testing occurred twice before and once after 4 weeks of right-handed isometric handgrip training totaling 120 weekly repetitions. Measures were maximal isometric handgrip and wrist flexion torque, muscle thickness, and muscle activation (electromyography; EMG). Grip strength was greater in both limbs posttraining, pooled across groups (P 0.103). Both LF and HF induced cross-education of grip strength to the untrained limb, but HF did not reduce asymmetry. These findings have implications for injury rehabilitation. Muscle Nerve 56: 689-695, 2017. © 2017 Wiley Periodicals, Inc.

  18. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakage...

  19. Evolution of Very High Frequency Power Supplies

    DEFF Research Database (Denmark)

    Knott, Arnold; Andersen, Toke Meyer; Kamby, Peter

    2013-01-01

    The ongoing demand for smaller and lighter power supplies is driving the motivation to increase the switching frequencies of power converters. Drastic increases however come along with new challenges, namely the increase of switching losses in all components. The application of power circuits use...

  20. High frequency of non-nocturnal hypoglycemia was associated with poor sleep quality measure by Pittsburg Sleep Quality Index in patients with diabetes receiving insulin therapy: Diabetes Distress and Care Registry at Tenri (DDCRT 4).

    Science.gov (United States)

    Hayashino, Y; Tsujii, S; Ishii, H

    2013-11-01

    To investigate the temporal association between frequency of non-nocturnal hypoglycemia and sleep quality among patients with diabetes receiving insulin therapy.We used data from 1 513 patients with diabetes receiving insulin therapy. We estimated the relative risks (RR) of the frequency of non-nocturnal hypoglycemia for poor sleep quality measured by the Pittsburgh Sleep Quality Index.The average age and HbA1c value of the patients were 63.7 years and 7.8%, respectively. Compared with poor sleep quality in patients without any type of non-nocturnal disabling hypoglycemia (NNDH), the multivariable-adjusted RR values for poor sleep quality were 1.30 (95% confidence interval [CI], 1.06-1.61) and 1.37 (95% CI, 0.96-1.95) in patients who experienced 1-4 and ≥5 episodes of NNDH, respectively (p=0.004). Experiencing non-nocturnal severe hypoglycemia (NNSH) once in the past 90 days significantly increased the risk of poor sleep quality by 1.54 episodes (95% CI, 1.16-2.05; p=0.003). By adding the presence of depression as a variable to the multivariable-adjusted model, these associations were attenuated because we did not observe any significant association between NNDH and poor sleep quality (p=0.178). However, a significant association between NNSH and poor sleep quality was observed (RR=1.43; 95% CI, 1.09-1.90; p=0.011).A high frequency of non-nocturnal hypoglycemia was associated with poor sleep quality in patients with diabetes receiving insulin therapy. Our data also suggested that the association of NNDH, and not NNSH, was mediated by comorbid depression. © J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York.

  1. Phosphorus geochemical cycling inferences from high frequency lake monitoring

    Science.gov (United States)

    Crockford, Lucy; Jordan, Philip; Taylor, David

    2013-04-01

    Freshwater bodies in Europe are required to return to good water quality status under the Water Framework Directive by 2015. A small inter-drumlin lake in the northeast of Ireland has been susceptible to eutrophic episodes and the presence of algal blooms during summer since annual monitoring began in 2002. While agricultural practice has been controlled by the implementation of the Nitrates Directive in 2006, the lake is failing to recover to good water quality status to meet with the Water Framework Directive objectives. Freshwaters in Ireland are regarded, in the main, as phosphorus (P) limited so identifying the sources of P possibly fuelling the algal blooms may provide an insight into how to improve water quality conditions. In a lake, these sources are divided between external catchment driven loads, as a result of farming and point sources, and P released from sediments made available to photic waters through internal lake mechanisms. High frequency sensors on data-sondes, installed on the lake in three locations, have provided chlorophyll a, redox potential, dissolved oxygen, temperature, pH, conductivity and turbidity data since March 2010. A data-sonde was installed in the hypolimnion to observe the change in lake conditions as P is released from lake sediments as a result of geochemical cycling with iron during anoxic periods. As compact high frequency sampling equipment for P analysis is still in its infancy for freshwaters, a proxy measurement of geochemical cycling in lakes would be useful to determine fully the extent of P contribution from sediments to the overall P load. Phosphorus was analysed once per month along with a number of other parameters and initial analysis of the high frequency data has shown changes in readings when known P release from lake sediments has occurred. Importantly, these data have shown when these P enriched hypolimnetic waters may be re-introduced to shallower waters in the photic zone, by changes in dissolved oxygen

  2. Respiratory Frequency during Exercise: The Neglected Physiological Measure

    Directory of Open Access Journals (Sweden)

    Andrea Nicolò

    2017-12-01

    Full Text Available The use of wearable sensor technology for athlete training monitoring is growing exponentially, but some important measures and related wearable devices have received little attention so far. Respiratory frequency (fR, for example, is emerging as a valuable measurement for training monitoring. Despite the availability of unobtrusive wearable devices measuring fR with relatively good accuracy, fR is not commonly monitored during training. Yet fR is currently measured as a vital sign by multiparameter wearable devices in the military field, clinical settings, and occupational activities. When these devices have been used during exercise, fR was used for limited applications like the estimation of the ventilatory threshold. However, more information can be gained from fR. Unlike heart rate, V˙O2, and blood lactate, fR is strongly associated with perceived exertion during a variety of exercise paradigms, and under several experimental interventions affecting performance like muscle fatigue, glycogen depletion, heat exposure and hypoxia. This suggests that fR is a strong marker of physical effort. Furthermore, unlike other physiological variables, fR responds rapidly to variations in workload during high-intensity interval training (HIIT, with potential important implications for many sporting activities. This Perspective article aims to (i present scientific evidence supporting the relevance of fR for training monitoring; (ii critically revise possible methodologies to measure fR and the accuracy of currently available respiratory wearables; (iii provide preliminary indication on how to analyze fR data. This viewpoint is expected to advance the field of training monitoring and stimulate directions for future development of sports wearables.

  3. Homodyne and heterodyne optical interferometry for frequency dependent piezoelectric displacement measurement

    Science.gov (United States)

    Delahoussaye, Keith; Guo, Ruyan; Bhalla, Amar

    2014-09-01

    The electromechanical coupling in piezoelectric materials has been widely studied however a unified view of this interaction as function of frequencies using different measurement techniques has not previously been available. This study examines and compares multiple optical based homodyne and heterodyne interferometry techniques for displacement measurement over a wide range of frequencies and including a comparison made by using a commercial Laser Doppler Vibrometer. Ferroelectric lead titanate PbTiO3 with high ferroelectric strain is studied in this work. Frequency dependence of the electromechanical displacement is obtained using multiple techniques and the emphasis is given to near resonant frequency interrogations.

  4. High frequency modeling of power transformers. Stresses and diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Bjerkan, Eilert

    2005-05-15

    measurements are done on impregnated press board at different temperatures and moisture-levels. Dielectric loss factor is found to be twice the corresponding value for impregnated paper at frequencies from 50 khz to 1MHz. Moisture has a minor effect on the losses when frequency approaches 1MHz. Service-aged paper (impregnated) is also tested in order to investigate other ageing-effects than produced water, but the test show the same decreasing influence at higher frequencies as impregnated press board with moisture added. The following main conclusions were drawn from this work: A simple, analytical approach cannot be used to build a versatile high frequency power transformer model. The reason being mainly the lack of a proper representation of the iron core, since a FEM-representation without the core did not increase coherence to measurements significantly. A proper representation of the iron core is very important for the calculation of inductances. Losses mainly originate from the core at intermediate frequencies (10-200 khz), and not only from eddy currents in the windings as traditionally assumed. The permeability seem to be of less importance as long as it is well above permeability for oil, since the internal resonances mainly depends on the leakage inductances. The core leg equivalent is important for the leakage field and determines the leakage inductances and winding losses. Using a frequency-dependent complex permeability in a FEM-simulation makes possible an accurate representation of core and windings using a coarse mesh. If coating resistivity is sufficiently low to create interlaminar currents/ losses, the iron laminates should be represented by a 2-dimensional complex permeability. Coating parameters are seldom available. Dielectric properties of power transformer insulating materials depend on frequency, temperature, moisture, ageing and pressure. Temperature has minor influence on FRA-signatures, other parameters have practically no influence. Impulse- and

  5. High-frequency analog integrated circuit design

    CERN Document Server

    1995-01-01

    To learn more about designing analog integrated circuits (ICs) at microwave frequencies using GaAs materials, turn to this text and reference. It addresses GaAs MESFET-based IC processing. Describes the newfound ability to apply silicon analog design techniques to reliable GaAs materials and devices which, until now, was only available through technical papers scattered throughout hundred of articles in dozens of professional journals.

  6. Brillouin frequency shift measurement with virtually controlled sensitivity

    Science.gov (United States)

    Tanaka, Yosuke; Ozaki, Yuta

    2017-06-01

    We propose measuring the change in Brillouin frequency shift (BFS) in an optical fiber with virtually controlled sensitivity based on the Vernier effect using a multimode pump and probe light. We measure BFS from the envelope curve of the spectra for multimode Stokes light without scanning the probe frequency. The sensitivity of BFS is virtually controlled by changing the difference in the mode spacing between the pump and the probe. It is experimentally demonstrated that the virtual sensitivity is controlled from -1.1 to 1.1 GHz/K, the maximum value of which is 1,100 times higher than the standard BFS of 1 MHz/K.

  7. High-frequency instability of the sheath-plasma resonance

    Science.gov (United States)

    Stenzel, R. L.

    1989-01-01

    Coherent high frequency oscillations near the electron plasma frequency (omega approx. less than omega sub p) are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diode-like electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening and copious harmonics. The fundamental instability is a bounded oscillation due to wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres) which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line broadening mechanism was identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burst-like RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

  8. Implementation of Low Frequency Ac to High Frequency Ac with Single Stage Zvs-Pwm Inverter

    OpenAIRE

    S. Arumugam S. Ramareddy M. Sridhar

    2011-01-01

    This paper presents a novel soft-switching pulse width modulation (PWM) utility frequency AC to high frequency (HF) AC power conversion circuit incorporating boost-active clamp single stage inverter topology. This power converter is more suitable and acceptable for cost effective HF consumer induction heating applications. Its operating principle is presented. The operating performances of this high frequency inverter using the latest insulated gate bipolar transistors are illustrated, which ...

  9. High-Frequency Percussive Ventilation: Pneumotachograph Validation and Tidal Volume Analysis

    Science.gov (United States)

    2010-06-01

    percussive ventilation (HFPV) is an increasingly used mode of mechanical ventilation , for which there is no proven real-time means of measuring delivered... mechanical ventilation ; tidal volume; VT; pneumotachography. [Respir Care 2010;55(6):734–740] Introduction Clinical application of high-frequency percussive...conventional mechanical ventilation (Fig. 1). How- ever, neither the low-frequency nor the high-frequency volumes administered by HFPV are measured by the

  10. High-frequency homogenization of zero frequency stop band photonic and phononic crystals

    CERN Document Server

    Antonakakis, Tryfon; Guenneau, Sebastien

    2013-01-01

    We present an accurate methodology for representing the physics of waves, for periodic structures, through effective properties for a replacement bulk medium: This is valid even for media with zero frequency stop-bands and where high frequency phenomena dominate. Since the work of Lord Rayleigh in 1892, low frequency (or quasi-static) behaviour has been neatly encapsulated in effective anisotropic media. However such classical homogenization theories break down in the high-frequency or stop band regime. Higher frequency phenomena are of significant importance in photonics (transverse magnetic waves propagating in infinite conducting parallel fibers), phononics (anti-plane shear waves propagating in isotropic elastic materials with inclusions), and platonics (flexural waves propagating in thin-elastic plates with holes). Fortunately, the recently proposed high-frequency homogenization (HFH) theory is only constrained by the knowledge of standing waves in order to asymptotically reconstruct dispersion curves an...

  11. Frequency swept fibre laser for wind speed measurements

    DEFF Research Database (Denmark)

    Pedersen, Anders Tegtmeier

    continuous wave (CW) and pulsed lidars. A light source capable of emitting such a pulse train is suggested. A theoretical description of all components constituting the light source is presented, and a time dependent model is developed and compared to measurements as well as to previous theoretical work from......This PhD thesis builds around a light source forming the basis for a novel type of wind measuring lidar. The lidar emits a train of laser pulses with each pulse being separated from its neighbours in frequency, while being closely spaced in time, thus combining the advantages of conventional...... the scientific literature. The model presented shows good agreement with the experimental results regarding the pulse train envelope as well as the individual pulses. A model adopted from the literature is subsequently expanded to incorporate frequency components other than the main signal frequency and compared...

  12. RF MEMS Fractal Capacitors With High Self-Resonant Frequencies

    KAUST Repository

    Elshurafa, Amro M.

    2012-07-23

    This letter demonstrates RF microelectromechanical systems (MEMS) fractal capacitors possessing the highest reported self-resonant frequencies (SRFs) in PolyMUMPS to date. Explicitly, measurement results show SRFs beyond 20 GHz. Furthermore, quality factors higher than 4 throughout a band of 1-15 GHz and reaching as high as 28 were achieved. Additional benefits that are readily attainable from implementing fractal capacitors in MEMS are discussed, including suppressing residual stress warping, eliminating the need for etching holes, and reducing parasitics. The latter benefits were acquired without any fabrication intervention. © 2011 IEEE.

  13. High-Speed Low-Jitter Frequency Multiplication in CMOS

    NARCIS (Netherlands)

    van de Beek, R.C.H.

    2004-01-01

    This thesis deals with high-speed Clock and Frequency Multiplication. The term `high-speedù applies to both the output and the reference frequency of the multiplier. Much emphasis is placed on analysis and optimization of the total timing inaccuracies, and on implementing a high-speed feedback

  14. Optical Transmitter Terminal for Selective RF High Frequency Bans Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the proposal work is to investigate the highly innovative conceptual design of an optical communication selective frequency transmitter terminal...

  15. Multifunctional Magnetodielectric Composites for Antenna and High Frequency Applications

    National Research Council Canada - National Science Library

    Zhang, Xiaokai; Golt, Michael C; Ekiert, Jr., Thomas F; Yarlagadda, Shridhar; Unruh, Karl M; Xaio, John Q

    2006-01-01

    Miniaturization of high frequency antennas while maintaining desirable bandwidth, impedance, and loss characteristics has recently attracted great attention in part due to the development of metamaterials...

  16. A precise measurement of the B-0 meson oscillation frequency

    NARCIS (Netherlands)

    Aaij, R.; Beteta, C. Abelian; Adeva, B.; Adinolfi, M.; Affolder, A.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Ali, S.; Alkhazov, G.; Cartelle, P. Alvarez; Alves, A. A.; Amato, S.; Amerio, S.; Amhis, Y.; An, L.; Anderlini, L.; Andreassi, G.; Andreotti, M.; Andrews, J. E.; Appleby, R. B.; Gutierrez, O. Aquines; Archilli, F.; d' Argent, P.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Baalouch, M.; Bachmann, S.; Back, J. J.; Radalov, A.; Baesso, C.; Baldini, W.; Barlow, R. J.; Barschel, C.; Barsuk, S.; Barter, W.; Batozskaya, V.; Battista, V.; Beaucourt, L.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Bel, L. J.; Bellee, V.; Belloli, N.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Benson, S.; Benton, J.; Berezhnoy, A.; Bernet, R.; Bertolin, A.; Bettler, M-O; van Beuzekom, M.; Bien, A.; Bifani, S.; Billoir, P.; Bird, T.; Birnkraut, A.; Bizzeti, A.; Blake, T.; Blanc, F.; Blouw, J.; Blusk, S.; Bocci, V.; Bondar, A.; Bondar, N.; Bonivento, W.; Borghi, S.; Borsato, M.; Bowcock, T. J. V.; Bowen, E.; Bozzi, C.; Braun, S.; Britsch, M.; Britton, T.; Brodzicka, J.; Brook, N. H.; Buchanan, E.; Bursche, A.; Buytaert, J.; Cadeddu, S.; Calabrese, R.; Calvi, M.; Calvo Gomez, M.; Campana, P.; Perez, D. Campora; Capriotti, L.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carniti, P.; Carson, L.; Carvalho Akiba, K.; Casse, G.; Cassina, L.; Garcia, L. Castillo; Cattaneo, M.; Cauet, Ch; Cavallero, G.; Cenci, R.; Charles, M.; Charpentier, Ph.; Chefdeville, M.; Cheung, S-F; Chiapolini, N.; Chrzaszcz, M.; Vidal, X. Cid; Ciezarek, G.; Clarke, P. E. L.; Clemencic, M.; Cliff, H. V.; Closier, J.; Coco, V.; Cogan, J.; Cogneras, E.; Cogoni, V.; Cojocariu, L.; Collazuol, G.; Collins, P.; Comerma-Montells, A.; Contu, A.; Cook, A.; Coombes, M.; Coquereau, S.; Corti, G.; Corvo, M.; Couturier, B.; Cowan, G. A.; Craik, D. C.; Crocombe, A.; Cruz Torres, M.; Cunliffe, S.; Currie, R.; D'Ambrosio, C.; Dall'Occo, E.; Dalseno, J.; David, P. N. Y.; Davis, A.; De Aguiar Francisco, O.; De Bruyn, K.; De Capua, S.; De Cian, M.; De Miranda, J. M.; De Paula, L.; De Simone, P.; Dean, C-T; Decamp, D.; Deckenhoff, M.; Del Buono, L.; Deleage, N.; Demmer, M.; Derkach, D.; Deschamps, O.; Dettori, F.; Dey, B.; Di Canto, A.; Di Ruscio, F.; Donleavy, S.; Dordei, F.; Dorigo, M.; Dosil Suarez, A.; Dossett, D.; Dovbnya, A.; Dreimanis, K.; Dufour, L.; Dujany, G.; Dupertuis, F.; Durante, P.; Dzhelyadin, R.; Dziurda, A.; Dzyuba, A.; Easo, S.; Egede, U.; Egorychev, V.; Eidelman, S.; Eisenhardt, S.; Eitschberger, U.; Ekelhof, R.; Eklund, L.; El Rifai, I.; Elsasser, Ch.; Ely, S.; Esen, S.; Evans, H. M.; Evans, T.; Falabella, A.; Farber, C.; Farley, N.; Farry, S.; Fay, R.; Ferguson, D.; Fernandez Albor, V.; Ferrari, F.; Ferreira Rodrigues, F.; Ferro-Luzzi, M.; Filippov, S.; Fiore, M.; Fiorini, M.; Firlej, M.; Fitzpatrick, C.; Fiutowski, T.; Fohl, K.; Fol, P.; Fontana, M.; Fontanelli, F.; Forshaw, D. C.; Forty, R.; Frei, C.; Frosini, M.; Furfaro, E.; Gallas Torreira, A.; Galli, D.; Gallorini, S.; Gambetta, S.; Gandelman, M.; Gandini, P.; Garcia Pardinas, J.; Tico, J. Gana; Garrido, L.; Gascon, D.; Gaspar, C.; Gauld, R.; Gavardi, L.; Gazzoni, G.; Gerick, D.; Gersabeck, E.; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Giani, S.; Gibson, V.; Girard, O. G.; Giubega, L.; Gligorov, V. V.; Gobel, C.; Golubkov, D.; Golutvin, A.; Gotti, C.; Gandara, M. Grabalosa; Graciani Diaz, R.; Cardoso, L. A. Granado; Grauges, E.; Graverini, E.; Graziani, G.; Grecu, A.; Greening, E.; Gregson, S.; Griffith, P.; Grillo, L.; Grunberg, O.; Gui, B.; Gushchin, E.; Guz, Yu; Gys, T.; Hadavizadeh, T.; Hadjivasiliou, C.; Haefeli, G.; Haen, C.; Haines, S. C.; Hall, S.; Hamilton, B.; Hansmann-Menzemer, S.; Harnew, N.; Harnew, S. T.; Harrison, J.; He, J.; Head, T.; Heijne, V.; Heister, A.; Hennessy, K.; Henrard, P.; Henry, L.; Hernando Morata, J. A.; van Herwijnen, E.; Hess, M.; Hicheur, A.; Hill, D.; Hoballah, M.; Hombach, C.; Hulsbergen, W.; Humair, T.; Hutchcroft, D.; Hynds, D.; Idzik, M.; Ilten, P.; Jacobsson, R.; Jalocha, J.; Jans, E.; Jawahery, A.; Jing, F.; John, M.; Johnson, D.; Jones, C. R.; Joram, C.; Jost, B.; Jurik, N.; Kandybei, S.; Kanso, W.; Karacson, M.; Karbach, T. M.; Karodia, S.; Kecke, M.; Kelsey, M.; Kenyon, I. R.; Kenzie, M.; Ketel, T.; Khanji, B.; Khurewathanakul, C.; Kirn, T.; Klaver, S.; Klimaszewski, K.; Kochebina, O.; Kolpin, M.; Komarov, I.; Koppenburg, P.; Kozeiha, M.; Kravchuk, L.; Kreplin, K.; Kreps, M.; Krocker, G.; Krokovny, P.; Krzemien, W.; Kucewicz, W.; Kucharczyk, M.; Kudryavtsev, V.; Kuonen, A. K.; Kurek, K.; Kvaratskheliya, T.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lambert, D.; Lanfranchi, G.; Langenbruch, C.; Langhans, B.; Latham, T.; Lazzeroni, C.; Le Gac, R.; van Leerdam, J.; Lees, J-P; Lefevre, R.; Leflat, A.; Lefrancois, J.; Lemos Cid, E.; Leroy, O.; Lesiak, T.; Leverington, B.; Likhomanenko, T.; Liles, M.; Lindner, R.; Linn, C.; Lionetto, F.; Loh, D.; Longstaff, I.; Lopes, J. H.; Lucchesi, D.; Lucio Martinez, M.; Luo, H.; Lupato, A.; Luppi, E.; Lupton, O.; Lusardi, N.; Lusiani, A.; Machefert, F.; Maciuc, F.; Maev, O.; Maguire, K.; Malde, S.; Malinin, A.; Manca, G.; Mancinelli, G.; Manning, P.; Mapelli, A.; Maratas, J.; Marchand, J. F.; Marconi, U.; Marin Benito, C.; Marino, P.; Marks, J.; Martellotti, G.; Martinelli, M.; Martinez Santos, D.; Martinez Vidal, F.; Martins Tostes, D.; Massafferri, A.; Matev, R.; Mathad, A.; Mathe, Z.; Matteuzzi, C.; Mauri, A.; Maurin, B.; Mazurov, A.; McCann, M.; McCarthy, J.; Mcnab, A.; McNulty, R.; Meadows, B.; Meier, F.; Melnychuk, D.; Merk, M.; Michielin, E.; Milanes, D. A.; Minard, M-N; Mitzel, D. S.; Molina Rodriguez, J.; Monroy, I. A.; Monteil, S.; Morandin, M.; Morawski, P.; Morda, A.; Morello, M. J.; Moron, J.; Morriss, A. B.; Mountain, R.; Muheim, F.; Mulller, D.; Mueller, J.; Mueller, V.; Mussini, M.; Muster, B.; Naik, P.; Nakada, T.; Nandakumar, R.; Nandi, A.; Nasteva, I.; Needham, M.; Neri, N.; Neubert, S.; Neufeld, N.; Neuner, M.; Nguyen, A. D.; Nguyen-Mau, C.; Niess, V.; Niet, R.; Nikitin, N.; Nikodem, T.; Novoselov, A.; O'Hanlon, D. P.; Oblakowska-Mucha, A.; Obraztsov, V.; Ogilvy, S.; Okhrimenko, O.; Oldeman, R.; Onderwater, C. J. G.; Osorio Rodrigues, B.; Otalora Goicochea, J. M.; Otto, A.; Owen, P.; Oyanguren, A.; Palano, A.; Palombo, F.; Palutan, M.; Papanestis, A.; Pappagallo, M.; Pappalardo, L. L.; Pappenheimer, C.; Parkes, C.; Passaleva, G.; Patel, G. D.; Patrignani, C.; Pearce, A.; Pellegrino, A.; Penso, G.; Altarelli, M. Pepe; Perazzini, S.; Perret, P.; Pescatore, L.; Petridis, K.; Petrolini, A.; Petruzzo, M.; Picatoste Olloqui, E.; Pietrzyk, B.; Pilar, T.; Pinci, D.; Pistone, A.; Piucci, A.; Playfer, S.; Plo Casasus, M.; Poikela, T.; Polci, F.; Poluektov, A.; Polyakov, I.; Polycarpo, E.; Popov, A.; Popov, D.; Popovici, B.; Potterat, C.; Price, E.; Price, J. D.; Prisciandaro, J.; Pritchard, A.; Prouve, C.; Pugatch, V.; Navarro, A. Puig; Punzi, G.; Qian, W.; Quagliani, R.; Rachwal, B.; Rademacker, J. H.; Rama, M.; Rangel, M. S.; Raniuk, I.; Rauschmayr, N.; Raven, G.; Redi, F.; Reichert, S.; Reid, M. M.; dos Reis, A. C.; Ricciardi, S.; Richards, S.; Rihl, M.; Rinnert, K.; Rives Molina, V.; Rodrigues, A. B.; Rodrigues, E.; Rodriguez Lopez, J. A.; Perez, P. Rodriguez; Roiser, S.; Romanovsky, V.; Romero Vidal, A.; Ronayne, J. W.; Rotondo, M.; Rouvinet, J.; Ruf, T.; Ruiz Valls, P.; Saborido Silva, J. J.; Sagidova, N.; Sail, P.; Saitta, B.; Salustino Guimaraes, V.; Sanchez Mayordomo, C.; Sanmartin Sedes, B.; Santacesaria, R.; Santamarina Rios, C.; Santimaria, M.; Santovetti, E.; Sarti, A.; Satriano, C.; Satta, A.; Saunders, D. M.; Savrina, D.; Schael, S.; Schindler, H.; Schlupp, M.; Schmelling, M.; Schmelzer, T.; Schmidt, B.; Schneider, O.; Schopper, A.; Schubiger, M.; Schune, M-H; Schwemmer, R.; Sciascia, B.; Sciubba, A.; Semennikov, A.; Sergi, A.; Serra, N.; Serrano, J.; Sestini, L.; Seyfert, P.; Shapkin, M.; Shapoval, I.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, V.; Shires, A.; Siddi, B. G.; Coutinho, R. Silva; Silva de Oliveira, L.; Simi, G.; Sirendi, M.; Skidmore, N.; Skwarnicki, T.; Smiih, E.; Smith, I. T.; Snoek, H.; Sokoloff, M. D.; Soler, F. J. P.; Soomro, F.; Souza, D.; Souza De Paula, B.; Spaan, B.; Spradlin, P.; Sridharan, S.; Stagni, F.; Stahl, M.; Stahl, S.; Stefkova, S.; Steinkamp, O.; Stenyakin, O.; Stevenson, S.; Stone, S.; Storaci, B.; Stracka, S.; Straticiuc, M.; Straumann, U.; Sutcliffe, W.; Swientek, K.; Swientek, S.; Syropoulos, V.; Szczekowski, M.; Szczypka, P.; Szumlak, T.; T'Jampens, S.; Tayduganov, A.; Tekampe, T.; Teklishyn, M.; Tellarini, G.; Teubert, F.; van Tilburg, J.; Tisserand, V.; Tobin, M.; Todd, J.; Tolk, S.; Tomassetti, L.; Tonelli, D.; Topp-Joergensen, S.; Torr, N.; Tournefier, E.; Tourneur, S.; Trabelsi, K.; Tresch, M.; Trisovic, A.; Tsaregorodtsev, A.; Tsopelas, P.; Tuning, N.; Ukleja, A.; Ustyuzhanin, A.; Uwer, U.; Vacca, C.; Vagnoni, V.; Valenti, G.; Vallier, A.; Gomez, R. Vazquez; Vazquez Regueiro, P.; Vazquez Sierra, C.; Vecchi, S.; van Veghel, M.; Velthuis, J. J.; Veltri, M.; Veneziano, G.; Vesterinen, M.; Viaud, B.; Vieira, D.; Vieites Diaz, M.; Vilasis-Cardona, X.; Vollhardt, A.; Volyanskyy, D.; Voong, D.; Vorobyev, A.; Vorobyev, V.; Voss, C.; Waldi, R.; Wallace, C.; Wallace, R.; Wandernoth, S.; Ward, D. R.; Watson, N. K.; Websdale, D.; Weiden, A.; Whitehead, M.; Wilkinson, G.; Williams, T.; Wilson, F. F.; Wimberley, J.; Wishahi, J.; Wislicki, W.; Witek, M.; Wormser, G.; Wotton, S. A.; Wright, S.; Wyllie, K.; Xie, Y.; Yang, Z.; Yu, J.; Yuan, X.; Yushchenko, O.; Zangoli, M.; Zavertyaev, M.; Zhelezov, A.; Zhokhov, A.; Zhong, L.; Zhukov, V.; Zucchelli, S.

    2016-01-01

    The oscillation frequency, Delta m(d), of B-0 mesons is measured using semileptonic decays with a D- or D*(-) meson in the final state. The data sample corresponds to 3.0 fb(-1) of pp collisions, collected by the LHCb experiment at centre-of-mass energies root s = 7 and 8 TeV. A combination of the

  17. MEASUREMENT OF FORMANT FREQUENCIES AND BANDWIDTHS IN SINGING

    NARCIS (Netherlands)

    SCHUTTE, HK; MILLER, DG; SVEC, JG

    That singers under certain circumstances adjust the articulation of the vocal tract (formant tuning) to enhance acoustic output is both apparent from measurements and understood in theory. The precise effect of a formant on an approaching (retreating) harmonic as the latter varies in frequency

  18. The multi-frequency sodar with high temporal resolution

    Directory of Open Access Journals (Sweden)

    Rostislav D. Kouznetsov

    2009-05-01

    Full Text Available The new sodar LATAN-3M with a frequency-coded sounding signal was developed, manufactured, and successfully tested at the Obukhov Institute for Atmospheric Physics. The sodar emits a sequence of sounding pulses at different frequencies and then averages the Doppler spectra for each range gate over the ensemble of frequencies. The field tests have proved the significant advantages of a multi-frequency technique in comparison with a single-frequency one. The use of eight different frequencies halves the minimal acceptable signal to noise ratio compared to single-frequency sounding. Moreover, the multi-frequency mode improves the accuracy of instantaneous values of measured parameters and significantly increases the reliability in recognizing noisy echo-signals.

  19. Frequency of inappropriate medical exceptions to quality measures.

    Science.gov (United States)

    Persell, Stephen D; Dolan, Nancy C; Friesema, Elisha M; Thompson, Jason A; Kaiser, Darren; Baker, David W

    2010-02-16

    Quality improvement programs that allow physicians to document medical reasons for deviating from guidelines preserve clinicians' judgment while enabling them to strive for high performance. However, physician misconceptions or gaming potentially limit programs. To implement computerized decision support with mechanisms to document medical exceptions to quality measures and to perform peer review of exceptions and provide feedback when appropriate. Observational study. Large internal medicine practice. Patients eligible for 1 or more quality measures. A peer-review panel judged medical exceptions to 16 chronic disease and prevention quality measures as appropriate, inappropriate, or of uncertain appropriateness. Medical records were reviewed after feedback was given to determine whether care changed. Physicians recorded 650 standardized medical exceptions during 7 months. The reporting tool was used without any medical reason 36 times (5.5%). Of the remaining 614 exceptions, 93.6% were medically appropriate, 3.1% were inappropriate, and 3.3% were of uncertain appropriateness. Frequencies of inappropriate exceptions were 7 (6.9%) for coronary heart disease, 0 (0%) for heart failure, 10 (10.8%) for diabetes, and 2 (0.6%) for preventive services. After physicians received direct feedback about inappropriate exceptions, 8 of 19 (42%) changed management. The peer-review process took less than 5 minutes per case, but for each change in clinical care, 65 reviews were required. The findings could differ at other sites or if financial incentives were in place. Physician-recorded medical exceptions were correct most of the time. Peer review of medical exceptions can identify myths and misconceptions, but the process needs to be more efficient to be sustainable. Agency for Healthcare Research and Quality.

  20. Oscillations of the Boundary Layer and High-frequency QPOs

    Directory of Open Access Journals (Sweden)

    Blinova A. A.

    2014-01-01

    Full Text Available We observed persistent high-frequency oscillations of the boundary layer near an accreting, weakly-magnetized star in global 3D MHD simulations. The tilted dipole magnetic field is not strong enough to open a gap between the star and the disk. Instead, it forms a highly-wrapped azimuthal field near the surface of the star which slows down rotation of the disk matter, while a small tilt of the field excites oscillations of the boundary layer with a frequency below the Keplerian frequency. This mechanism may be responsible for the high-frequency oscillations in accreting neutron stars, white dwarfs and classical T Tauri stars.

  1. Measuring the Bunch Frequency Multiplication at CTF3

    CERN Document Server

    Bettoni, S; Corsini, R; Dabrowski, A; Doebert, S; Egger, D; Ferrari, A; Lefevre, T; Rabiller, A; Skowronski, PK; Soby, L; Tecker, F; Welsch, CP

    2010-01-01

    The CLIC Test Facility 3 (CTF3) is being built and commissioned by an international collaboration to test the feasibility of the proposed Compact Linear Collider (CLIC) drive beam generation scheme. Central to this scheme is the use of RF deflectors to inject bunches into a delay loop and a combiner ring, in order to transform the initial bunch frequency of 1.5 GHz from the LINAC to a final bunch frequency of 12 GHz. The optimization procedure relies on several steps. The active length of each ring is carefully adjusted to within less than millimetre accuracy using a wiggler magnet. The transverse optics of the machine must be set up in a way to ensure beam isochronicity. Diagnostics based on optical Streak camera and RF power measurements have been designed to measure the longitudinal behaviour of the beam during the combination. This paper presents their performance and recent measurements

  2. Intensity autocorrelation measurements of frequency combs in the terahertz range

    Science.gov (United States)

    Benea-Chelmus, Ileana-Cristina; Rösch, Markus; Scalari, Giacomo; Beck, Mattias; Faist, Jérôme

    2017-09-01

    We report on direct measurements of the emission character of quantum cascade laser based frequency combs, using intensity autocorrelation. Our implementation is based on fast electro-optic sampling, with a detection spectral bandwidth matching the emission bandwidth of the comb laser, around 2.5 THz. We find the output of these frequency combs to be continuous even in the locked regime, but accompanied by a strong intensity modulation. Moreover, with our record temporal resolution of only few hundreds of femtoseconds, we can resolve correlated intensity modulation occurring on time scales as short as the gain recovery time, about 4 ps. By direct comparison with pulsed terahertz light originating from a photoconductive emitter, we demonstrate the peculiar emission pattern of these lasers. The measurement technique is self-referenced and ultrafast, and requires no reconstruction. It will be of significant importance in future measurements of ultrashort pulses from quantum cascade lasers.

  3. A New Instantaneous Frequency Measure Based on The Stockwell Transform

    Science.gov (United States)

    yedlin, M. J.; Ben-Horrin, Y.; Fraser, J. D.

    2011-12-01

    We propose the use of a new transform, the Stockwell transform[1], as a means of creating time-frequency maps and applying them to distinguish blasts from earthquakes. This new transform, the Stockwell transform can be considered as a variant of the continuous wavelet transform, that preserves the absolute phase.The Stockwell transform employs a complex Morlet mother wavelet. The novelty of this transform lies in its resolution properties. High frequencies in the candidate signal are well-resolved in time but poorly resolved in frequency, while the converse is true for low frequency signal components. The goal of this research is to obtain the instantaneous frequency as a function of time for both the earthquakes and the blasts. Two methods will be compared. In the first method, we will compute the analytic signal, the envelope and the instantaneous phase as a function of time[2]. The instantaneous phase derivative will yield the instantaneous angular frequency. The second method will be based on time-frequency analysis using the Stockwell transform. The Stockwell transform will be computed in non-redundant fashion using a dyadic representation[3]. For each time-point, the frequency centroid will be computed -- a representation for the most likely frequency at that time. A detailed comparison will be presented for both approaches to the computation of the instantaneous frequency. An advantage of the Stockwell approach is that no differentiation is applied. The Hilbert transform method can be less sensitive to edge effects. The goal of this research is to see if the new Stockwell-based method could be used as a discriminant between earthquakes and blasts. References [1] Stockwell, R.G., Mansinha, L. and Lowe, R.P. "Localization of the complex spectrum: the S transform", IEEE Trans. Signal Processing, vol.44, no.4, pp.998-1001, (1996). [2]Taner, M.T., Koehler, F. "Complex seismic trace analysis", Geophysics, vol. 44, Issue 6, pp. 1041-1063 (1979). [3] Brown, R

  4. High frequency oscillations in epilepsy surgery

    NARCIS (Netherlands)

    van 't Klooster, MA|info:eu-repo/dai/nl/413752623

    2016-01-01

    Epilepsy surgery is the sole treatment to cure patients with focal epilepsy. The chances on seizure freedom after surgery is determined by how well we can pinpoint the epileptic focus and delineate the margins of the disease tissue for resection. Intra-operative invasive EEG, measuring brain signals

  5. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-04-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The power supply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to the indispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer need considering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, but also parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits a simple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with stray capacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only a precise measurement procedure but also effective design information for series-load resonant converter. The plasma discharging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit model of the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasma generator is built and the designing procedures for appropriate selections of the corresponding resonant-circuit parameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along with a 22 kHz and over 8kV output, is realized and implemented.

  6. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-03-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The powersupply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to theindispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer needconsidering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, butalso parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits asimple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with straycapacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only aprecise measurement procedure but also effective design information for series-load resonant converter. The plasmadischarging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit modelof the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasmagenerator is built and the designing procedures for appropriate selections of the corresponding resonant-circuitparameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along witha 22 kHz and over 8kV output, is realized and implemented.

  7. High-frequency fatigue after alpine slalom skiing.

    Science.gov (United States)

    Tomazin, Katja; Dolenec, Ales; Strojnik, Vojko

    2008-05-01

    The aim of the study was to examine the presence of high-frequency fatigue (HFF) after simulated alpine slalom skiing race. Eight male alpine skiers (18.4+/-1.2 y.a., 182.3+/-3.5 cm, 80.5+/-3.4 kg) completed the study. Their average FIS points in slalom were 30.1+/-5.4. After the special skiing warm up, the following initial tests were performed: blood lactate concentration, twitch response of the relaxed VL muscle, knee torque during low- (20 Hz) and high-frequency (100 Hz) electrical stimulation of vastus lateralis muscle, and maximum, voluntary isometric knee extension torque. Then, subjects performed slalom with 45 gates, whose duration was approximately 45 s. The same test sequence, except blood lactate test was used after slalom and the measurements started exactly 60 and 180 s after slalom. Blood lactate concentration measurement started exactly 3 and 5 min after slalom. A 1x3 repeated measures; time-series design was used with one within factor of time (before 60 s, and 180 s after skiing). The average blood lactate level increased from 1.6 (0.6) pre-slalom to 7.1(1.6) mmol(-l) 15 min post-slalom (F2,14=70.1; P<0.001). Sixty seconds after slalom, twitch contraction time shortened from 78.2 (5.7) pre-slalom to 66.0 (7.2) ms post-slalom (F1.19,8.3=9.9; P<0.05). Peak twitch torque was potentiated from 21.6 (3.8) to 26.4 (5.3) Nm (F2,14=16.7; P<0.05). Slalom reduced high-frequency torque from 64.4 (35) to 58.2 (34.2) Nm 60 s post-slalom (F2,14=3.8; P<0.05), while low-frequency torque stayed virtually the same. Slalom induced HFF, which is typical of SSC exercises of maximum intensity and short duration.

  8. Review of sensors for low frequency seismic vibration measurement

    CERN Document Server

    Collette, C; Janssens, S; Artoos, K; Guinchard, M; Hauviller, C

    2011-01-01

    The objective of this report is to review the main different types of sensors used to measure seismic vibrations at low frequencies. After some basic background preliminaries, the main different types of relative measurements are first reviewed. Then, the following inertial sensors are treated: geophones, accelerometers and broadband seismometers. For each of these sensors, the basic working principle is explained, along with the main performances limitations. Each section ends with a tentative comparison of some commercial products, far from being exhaustive, but hopefully representative of the average characteristics of each family of sensors. The report finishes with a brief discussion on the modelling and measurement of the sensor noise

  9. Absolute frequency measurements on Mg{sup +} cooling transitions

    Energy Technology Data Exchange (ETDEWEB)

    Batteiger, Valentin; Herrmann, Maximilian; Knuenz, Sebastian; Bernhardt, Birgitta; Udem, Thomas; Haensch, Theodor W. [Max-Planck-Institut fuer Quantenoptik, Garching (Germany); Zhu, Feng; Schuessler, Hans [Texas A and M University, College Station, Texas (United States)

    2008-07-01

    We present isotopically resolved absolute frequency measurements of both fine structure components of the 3s-3p transition in single, trapped magnesium ions. The transitions are observed in the limit of unresolved sidebands, which would lead to strongly asymmetric line shapes due to cooling and heating if only one laser were swept over the resonance. A novel spectroscopy scheme based on sympathetic cooling and spatially resolved detection allows to observe symmetric lines. The measurements contribute to astronomical searches for drifts of the fine structure constant in quasar absorption spectra and improve the accuracy over previous measurements by two orders of magnitude.

  10. High frequency plant regeneration from desiccated calli of indica rice

    African Journals Online (AJOL)

    An efficient and reproducible protocol is required to achieve high frequency transformation from transformed calli. We report here high frequency plant regeneration from mature seed derived embryogenic calli of two recalcitrant indica rice cultivars HKR-46 and HKR-126 after partial desiccation treatment. Embryogenic and ...

  11. Effective properties of mechanical systems under high-frequency excitation at multiple frequencies

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel

    2008-01-01

    Effects of strong high-frequency excitation at multiple frequencies (multi-HFE) are analyzed for a class of generally nonlinear systems. The effects are illustrated for a simple pendulum system with a vibrating support, and for a parametrically excited flexible beam. For the latter, theoretical...

  12. Computing effective properties of nonlinear structures exposed to strong high-frequency loading at multiple frequencies

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel

    2006-01-01

    Effects of strong high-frequency excitation at multiple frequencies (multi-HFE) are analyzed for a class of generally nonlinear systems. The effects are illustrated for a simple pendulum system with a vibrating support, and for a parametrically excited flexible beam. For the latter, theoretical...

  13. FREQUENCY DETERMINATION OF HIGH-FREQUENCY LINK FOR PERCPECTIVE ELECTRIC ROLLING STOCK

    Directory of Open Access Journals (Sweden)

    D. O. Zabarylo

    2014-12-01

    Full Text Available Purpose. Total mileage of Ukrainian electric railways is distributed approximately equally between the areas of direct and alternating current. A double system of electric rolling stock is used to pass jointing places of different current kinds without train’s stop. Therefore introduction of such rolling stock of a new concept that is using an asynchronous traction drive is prospective for Ukrainian railways. Apart from advantages a rolling stock of similar concept has significant disadvantages, it is pulse energy consumption from the power supply, and it can affect the reliability of track automatic devices, and consequently, the train traffic safety. In addition the specific power of traction transformer is considerably inferior to the power density of other traction elements. The promising schemes using an intermediary link of increased frequency, which consist of a transformer and inverter, have been proposed for disadvantages amendments. The main task for the further introduction of prospective circuit is to determine the operating frequency for high frequency link. Methodology. The method of thermal parameters calculation of semiconductor devices has been used for determination switching transistors of maximum operating frequency. To obtain analytical expressions curves of energy, released during the IGBT (insulated-gate bipolar transistor switching from its current load approximation method is used. Findings. The permissible frequency of low-frequency link is determinated by load current of intermediate transformer. Operating frequency range of a link depending on load current has been determined. A comparative analysis of the switching characteristics of 65 class IGBT production by companies Infineon and ABB has been performed. Originality. The further determination method of the maximum operating frequency of intermediate link for circuit with high-frequency transformer has been developed. Practical value. The established operating

  14. Suppressing interfering scattered signals in swept-frequency radar measurements by using frequency domain Wiener filtering

    Science.gov (United States)

    Weissman, David E.; Staton, Leo D.

    1991-01-01

    A novel approach to the reduction of scattered, interfering signals that corrupt measurements of the signal backscattered from radar targets of interest is being developed. It is being explored with sphere measurements in an indoor microwave radar range. This method is based on the concept of Wiener filtering (which minimizes the difference between the signal plus noise and the desired signal in the time domain). In contrast to the traditional Wiener filter, in which the time domain error between two sequences are minimized, the approach reported uses the frequency domain phasor amplitudes of a swept frequency signal. It minimizes the difference (least-mean-square-magnitude) between the signal-plus-noise and the signal complex phasors, across the entire spectrum.

  15. High Security Chipless RFID Tags Using Frequency Shift Coding Technique

    Directory of Open Access Journals (Sweden)

    M. Sumi

    2017-09-01

    Full Text Available A high security chipless RFID tag designed using E shaped resonator is presented in this paper. The tag identity is encoded using Frequency Shift Coding technique. 144 different code words are possible in 2.78 to 3.85 GHz band using two E shaped resonators. The tag identity can be decoded from either amplitude or group delay information. The resonators are designed and fabricated on substrate C-MET LK4.3 of dielectric constant 4.3 and loss tangent 0.0018. Different tag combinations are designed and tested using bistatic measurement setup. Measurement results on realized prototypes are provided to ensure the reliability of the proposed design.

  16. Mechanical monolithic sensor for low-frequency seismic noise measurement

    Science.gov (United States)

    Acernese, Fausto; De Rosa, Rosario; Giordano, Gerardo; Romano, Rocco; Barone, Fabrizio

    2007-04-01

    This paper describes a new low-frequency seismic sensor for geophysical applications. The instrument is basically a monolithic tunable folded pendulum with an interferometric readout system, that can be configured as seismometer or as accelerometer. The monolithic mechanical design and the introduction of a laser interferometric technique for the readout implementation make it a very sensitive and compact instrument with a very good immunity to environmental noises. The theoretical sensitivity curve is calculated considering the brownian noise, the readout noise and the data acquisition noise. Preliminary tests on the mechanical performances of the monolithic structure and on the optical readout have been performed. Interesting result is the measured resonant frequency of the instrument of ~ 150mHz obtained with a rough tuning, demonstrating the feasibility of a resonant frequency of the order of 5mHz with a more refined tuning. The transfer function of the folded pendulum in open loop configuration is calculated measuring the resonant frequency and the quality factor for several step responses. Then a PID controller is added to implement the closed loop configuration. The mechanics of the seismic sensor, the optical scheme of the readout system, the theoretical predictions and the preliminary experimental performances as accelerometer are discussed in detail, together with the foreseen further improvements.

  17. Stress Recovery Effects of High- and Low-Frequency Amplified Music on Heart Rate Variability

    Directory of Open Access Journals (Sweden)

    Yoshie Nakajima

    2016-01-01

    Full Text Available Sounds can induce autonomic responses in listeners. However, the modulatory effect of specific frequency components of music is not fully understood. Here, we examined the role of the frequency component of music on autonomic responses. Specifically, we presented music that had been amplified in the high- or low-frequency domains. Twelve healthy women listened to white noise, a stress-inducing noise, and then one of three versions of a piece of music: original, low-, or high-frequency amplified. To measure autonomic response, we calculated the high-frequency normalized unit (HFnu, low-frequency normalized unit, and the LF/HF ratio from the heart rate using electrocardiography. We defined the stress recovery ratio as the value obtained after participants listened to music following scratching noise, normalized by the value obtained after participants listened to white noise after the stress noise, in terms of the HFnu, low-frequency normalized unit, LF/HF ratio, and heart rate. Results indicated that high-frequency amplified music had the highest HFnu of the three versions. The stress recovery ratio of HFnu under the high-frequency amplified stimulus was significantly larger than that under the low-frequency stimulus. Our results suggest that the high-frequency component of music plays a greater role in stress relief than low-frequency components.

  18. Stress Recovery Effects of High- and Low-Frequency Amplified Music on Heart Rate Variability.

    Science.gov (United States)

    Nakajima, Yoshie; Tanaka, Naofumi; Mima, Tatsuya; Izumi, Shin-Ichi

    Sounds can induce autonomic responses in listeners. However, the modulatory effect of specific frequency components of music is not fully understood. Here, we examined the role of the frequency component of music on autonomic responses. Specifically, we presented music that had been amplified in the high- or low-frequency domains. Twelve healthy women listened to white noise, a stress-inducing noise, and then one of three versions of a piece of music: original, low-, or high-frequency amplified. To measure autonomic response, we calculated the high-frequency normalized unit (HFnu), low-frequency normalized unit, and the LF/HF ratio from the heart rate using electrocardiography. We defined the stress recovery ratio as the value obtained after participants listened to music following scratching noise, normalized by the value obtained after participants listened to white noise after the stress noise, in terms of the HFnu, low-frequency normalized unit, LF/HF ratio, and heart rate. Results indicated that high-frequency amplified music had the highest HFnu of the three versions. The stress recovery ratio of HFnu under the high-frequency amplified stimulus was significantly larger than that under the low-frequency stimulus. Our results suggest that the high-frequency component of music plays a greater role in stress relief than low-frequency components.

  19. Linear High Resolution Frequency-Wavenumber Analysis

    Science.gov (United States)

    1976-03-01

    and 43-74. On 31 May 74 at 0313:11 an earthquake occurred in the vicinity of Unimak Island in the Aleutians. At 0326:57 a second event occurred in...Ms measurements un- available. The Unimak signal was expected at LASA about 0330 0 from 302 , with the Kazakh signal expected about 0406, in the...and 3180. In win- dows 1, 2, and 3 the detector is "triggering" on the ongoing coda from the Unimak earthquake. But in windows 4 and 5 it turns and

  20. A MEMS-based high frequency x-ray chopper

    Energy Technology Data Exchange (ETDEWEB)

    Siria, A; Schwartz, W; Chevrier, J [Institut Neel, CNRS-Universite Joseph Fourier Grenoble, BP 166, F-38042 Grenoble Cedex 9 (France); Dhez, O; Comin, F [ESRF, 6 rue Jules Horowitz, F-38043 Grenoble Cedex 9 (France); Torricelli, G [Department of Physics and Astronomy, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom)

    2009-04-29

    Time-resolved x-ray experiments require intensity modulation at high frequencies (advanced rotating choppers have nowadays reached the kHz range). We here demonstrate that a silicon microlever oscillating at 13 kHz with nanometric amplitude can be used as a high frequency x-ray chopper. We claim that using micro-and nanoelectromechanical systems (MEMS and NEMS), it will be possible to achieve higher frequencies in excess of hundreds of megahertz. Working at such a frequency can open a wealth of possibilities in chemistry, biology and physics time-resolved experiments.

  1. A MEMS-based high frequency x-ray chopper.

    Science.gov (United States)

    Siria, A; Dhez, O; Schwartz, W; Torricelli, G; Comin, F; Chevrier, J

    2009-04-29

    Time-resolved x-ray experiments require intensity modulation at high frequencies (advanced rotating choppers have nowadays reached the kHz range). We here demonstrate that a silicon microlever oscillating at 13 kHz with nanometric amplitude can be used as a high frequency x-ray chopper. We claim that using micro-and nanoelectromechanical systems (MEMS and NEMS), it will be possible to achieve higher frequencies in excess of hundreds of megahertz. Working at such a frequency can open a wealth of possibilities in chemistry, biology and physics time-resolved experiments.

  2. Advanced Extremely High Frequency Satellite (AEHF)

    Science.gov (United States)

    2015-12-01

    resistant communications for high priority military ground, sea, and air assets. The system consists of four satellites in Geosynchronous Earth Orbit that...submarine terminals, and airborne terminals. The mission control segment controls satellites on orbit , monitors satellite health, and provides...Schriever Air Force Base (AFB). Due to the proprietary nature of the AEHF Space Satellite (on- orbit ) Segment, this segment is not considered core and the

  3. Extended high frequency audiometry in users of personal listening devices.

    Science.gov (United States)

    Kumar, Poornima; Upadhyay, Prabhakar; Kumar, Ashok; Kumar, Sunil; Singh, Gautam Bir

    Noise exposure leads to high frequency hearing loss. Use of Personal Listening Devices may lead to decline in high frequency hearing sensitivity because of prolonged exposure to these devices at high volume. This study explores the changes in hearing thresholds by Extended High Frequency audiometry in users of personal listening devices. A descriptive, hospital based observational study was performed with total 100 subjects in age group of 15-30years. Subjects were divided in two groups consisting of 30 subjects (Group A) with no history of Personal Listening Devices use and (Group B) having 70 subjects with history of use of Personal Listening Devices. Conventional pure tone audiometry with extended high frequency audiometry was performed in all the subjects. Significant differences in hearing thresholds of Personal Listening Device users were seen at high frequencies (3kHz, 4kHz and 6kHz) and extended high frequencies (9kHz, 10kHz, 11kHz, 13kHz, 14kHz, 15kHz and 16kHz) with p value 5years usage at high volume. Thus, it can be reasonably concluded that extended high frequencies can be used for early detection of NIHL in PLD users. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Low-frequency measurement of leakage in enclosures

    Science.gov (United States)

    Sherman, Max; Modera, Mark

    1986-07-01

    A wide variety of enclosed structures either require or cannot entirely prevent leakage from their interior space to the outside. Existing methods for measuring such leakage have important disadvantages. We have developed a device and technique that permits leakage areas to be measured from within or without the enclosure without causing unacceptable disturbance. The apparatus uses low-frequency (1 Hz) acoustic monopoles to generate an internal pressure signal which is then analyzed synchronously to provide a measurement of leakage area. We have successfully applied this technique to measuring air tightness in residential houses, and believe it can be easily adapted for use in field, laboratory, or classroom applications. We are currently evaluating why the values we obtained were, on average, 14% lower than those obtained through conventional methods and we are investigating the apparent inability of the device, as presently designed, to measure large leaks.

  5. High-frequency multimodal atomic force microscopy

    Directory of Open Access Journals (Sweden)

    Adrian P. Nievergelt

    2014-12-01

    Full Text Available Multifrequency atomic force microscopy imaging has been recently demonstrated as a powerful technique for quickly obtaining information about the mechanical properties of a sample. Combining this development with recent gains in imaging speed through small cantilevers holds the promise of a convenient, high-speed method for obtaining nanoscale topography as well as mechanical properties. Nevertheless, instrument bandwidth limitations on cantilever excitation and readout have restricted the ability of multifrequency techniques to fully benefit from small cantilevers. We present an approach for cantilever excitation and deflection readout with a bandwidth of 20 MHz, enabling multifrequency techniques extended beyond 2 MHz for obtaining materials contrast in liquid and air, as well as soft imaging of delicate biological samples.

  6. Intramuscular Contributions to Low-Frequency Force Potentiation Induced by a High-Frequency Conditioning Stimulation

    Directory of Open Access Journals (Sweden)

    Arthur J. Cheng

    2017-09-01

    Full Text Available Electrically-evoked low-frequency (submaximal force is increased immediately following high-frequency stimulation in human skeletal muscle. Although central mechanisms have been suggested to be the major cause of this low-frequency force potentiation, intramuscular factors might contribute. Thus, we hypothesized that two intramuscular Ca2+-dependent mechanisms can contribute to the low-frequency force potentiation: increased sarcoplasmic reticulum Ca2+ release and increased myofibrillar Ca2+ sensitivity. Experiments in humans were performed on the plantar flexor muscles at a shortened, intermediate, and long muscle length and electrically evoked contractile force and membrane excitability (i.e., M-wave amplitude were recorded during a stimulation protocol. Low-frequency force potentiation was assessed by stimulating with a low-frequency tetanus (25 Hz, 2 s duration, followed by a high-frequency tetanus (100 Hz, 2 s duration, and finally followed by another low-frequency (25 Hz, 2 s duration tetanus. Similar stimulation protocols were performed on intact mouse single fibers from flexor digitorum brevis muscle, whereby force and myoplasmic free [Ca2+] ([Ca2+]i were assessed. Our data show a low-frequency force potentiation that was not muscle length-dependent in human muscle and it was not accompanied by any increase in M-wave amplitude. A length-independent low-frequency force potentiation could be replicated in mouse single fibers, supporting an intramuscular mechanism. We show that at physiological temperature (31°C this low-frequency force potentiation in mouse fibers corresponded with an increase in sarcoplasmic reticulum (SR Ca2+ release. When mimicking the slower contractile properties of human muscle by cooling mouse single fibers to 18°C, the low-frequency force potentiation was accompanied by minimally increased SR Ca2+ release and hence it could be explained by increased myofibrillar Ca2+ sensitivity. Finally, introducing a brief 200

  7. Intramuscular Contributions to Low-Frequency Force Potentiation Induced by a High-Frequency Conditioning Stimulation.

    Science.gov (United States)

    Cheng, Arthur J; Neyroud, Daria; Kayser, Bengt; Westerblad, Håkan; Place, Nicolas

    2017-01-01

    Electrically-evoked low-frequency (submaximal) force is increased immediately following high-frequency stimulation in human skeletal muscle. Although central mechanisms have been suggested to be the major cause of this low-frequency force potentiation, intramuscular factors might contribute. Thus, we hypothesized that two intramuscular Ca2+-dependent mechanisms can contribute to the low-frequency force potentiation: increased sarcoplasmic reticulum Ca2+ release and increased myofibrillar Ca2+ sensitivity. Experiments in humans were performed on the plantar flexor muscles at a shortened, intermediate, and long muscle length and electrically evoked contractile force and membrane excitability (i.e., M-wave amplitude) were recorded during a stimulation protocol. Low-frequency force potentiation was assessed by stimulating with a low-frequency tetanus (25 Hz, 2 s duration), followed by a high-frequency tetanus (100 Hz, 2 s duration), and finally followed by another low-frequency (25 Hz, 2 s duration) tetanus. Similar stimulation protocols were performed on intact mouse single fibers from flexor digitorum brevis muscle, whereby force and myoplasmic free [Ca2+] ([Ca2+]i) were assessed. Our data show a low-frequency force potentiation that was not muscle length-dependent in human muscle and it was not accompanied by any increase in M-wave amplitude. A length-independent low-frequency force potentiation could be replicated in mouse single fibers, supporting an intramuscular mechanism. We show that at physiological temperature (31°C) this low-frequency force potentiation in mouse fibers corresponded with an increase in sarcoplasmic reticulum (SR) Ca2+ release. When mimicking the slower contractile properties of human muscle by cooling mouse single fibers to 18°C, the low-frequency force potentiation was accompanied by minimally increased SR Ca2+ release and hence it could be explained by increased myofibrillar Ca2+ sensitivity. Finally, introducing a brief 200 ms pause

  8. A precise measurement of the $B^0$ meson oscillation frequency

    CERN Document Server

    Aaij, Roel; Adeva, Bernardo; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassi, Guido; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; d'Argent, Philippe; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Bel, Lennaert; Bellee, Violaine; Belloli, Nicoletta; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bertolin, Alessandro; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Billoir, Pierre; Bird, Thomas; Birnkraut, Alex; Bizzeti, Andrea; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Braun, Svende; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Buchanan, Emma; Bursche, Albert; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Capriotti, Lorenzo; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carniti, Paolo; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cavallero, Giovanni; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cogoni, Violetta; Cojocariu, Lucian; Collazuol, Gianmaria; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Crocombe, Andrew; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dall'Occo, Elena; Dalseno, Jeremy; David, Pieter; Davis, Adam; De Aguiar Francisco, Oscar; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Simone, Patrizia; Dean, Cameron Thomas; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Demmer, Moritz; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Dey, Biplab; Di Canto, Angelo; Di Ruscio, Francesco; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dufour, Laurent; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferrari, Fabio; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fohl, Klaus; Fol, Philip; Fontana, Marianna; Fontanelli, Flavio; Forshaw, Dean Charles; Forty, Roger; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garra Tico, Jordi; Garrido, Lluis; Gascon, David; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gazzoni, Giulio; Gerick, David; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianì, Sebastiana; Gibson, Valerie; Girard, Olivier Göran; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graverini, Elena; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadavizadeh, Thomas; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Heister, Arno; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Humair, Thibaud; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kecke, Matthieu; Kelsey, Matthew; Kenyon, Ian; Kenzie, Matthew; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Kirn, Thomas; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Kozeiha, Mohamad; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Krzemien, Wojciech; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kuonen, Axel Kevin; Kurek, Krzysztof; Kvaratskheliya, Tengiz; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Lemos Cid, Edgar; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Liu, Xuesong; Loh, David; Longstaff, Iain; Lopes, Jose; Lucchesi, Donatella; Lucio Martinez, Miriam; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Lusardi, Nicola; Lusiani, Alberto; Machefert, Frederic; Maciuc, Florin; Maev, Oleg; Maguire, Kevin; Malde, Sneha; Malinin, Alexander; Manca, Giulia; Mancinelli, Giampiero; Manning, Peter Michael; Mapelli, Alessandro; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Marks, Jörg; Martellotti, Giuseppe; Martin, Morgan; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathad, Abhijit; Mathe, Zoltan; Matteuzzi, Clara; Mauri, Andrea; Maurin, Brice; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; Meadows, Brian; Meier, Frank; Meissner, Marco; Melnychuk, Dmytro; Merk, Marcel; Michielin, Emanuele; Milanes, Diego Alejandro; Minard, Marie-Noelle; Mitzel, Dominik Stefan; Molina Rodriguez, Josue; Monroy, Ignacio Alberto; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Dominik; Müller, Janine; Müller, Katharina; Müller, Vanessa; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nandi, Anita; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Osorio Rodrigues, Bruno; Otalora Goicochea, Juan Martin; Otto, Adam; Owen, Patrick; Oyanguren, Maria Aranzazu; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Pappenheimer, Cheryl; Parkes, Christopher; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perret, Pascal; Pescatore, Luca; Petridis, Konstantinos; Petrolini, Alessandro; Petruzzo, Marco; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Piucci, Alessio; Playfer, Stephen; Plo Casasus, Maximo; Poikela, Tuomas; Polci, Francesco; Poluektov, Anton; Polyakov, Ivan; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Quagliani, Renato; Rachwal, Bartolomiej; Rademacker, Jonas; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Lopez, Jairo Alexis; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Ronayne, John William; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santimaria, Marco; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrina, Darya; Schael, Stefan; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmelzer, Timon; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schubiger, Maxime; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Semennikov, Alexander; Sergi, Antonino; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Siddi, Benedetto Gianluca; Silva Coutinho, Rafael; Silva de Oliveira, Luiz Gustavo; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Edmund; Smith, Eluned; Smith, Iwan Thomas; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Stefkova, Slavomira; Steinkamp, Olaf; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szumlak, Tomasz; T'Jampens, Stephane; Tayduganov, Andrey; Tekampe, Tobias; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Todd, Jacob; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Trabelsi, Karim; Tran, Minh Tâm; Tresch, Marco; Trisovic, Ana; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; van Veghel, Maarten; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Weiden, Andreas; Whitehead, Mark; Wilkinson, Guy; Wilkinson, Michael; Williams, Mark Richard James; Williams, Matthew; Williams, Mike; Williams, Timothy; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wyllie, Kenneth; Xie, Yuehong; Xu, Zhirui; Yang, Zhenwei; Yu, Jiesheng; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zhukov, Valery; Zucchelli, Stefano

    2016-07-21

    The oscillation frequency, $\\Delta m_d$, of $B^0$ mesons is measured using semileptonic decays with a $D^-$ or $D^{*-}$ meson in the final state, in a data sample of $pp$ collisions collected by the LHCb detector corresponding to an integrated luminosity of 3.0$\\mbox{fb}^{-1}$. A combination of the two decay modes gives $\\Delta m_d = (505.0 \\pm 2.1 \\pm 1.0) \\rm \\,ns^{-1}$, where the first uncertainty is statistical and the second is systematic. This is the most precise single measurement of this parameter. It is compatible with the current world average and has similar precision.

  9. High-frequency energy in singing and speech

    Science.gov (United States)

    Monson, Brian Bruce

    While human speech and the human voice generate acoustical energy up to (and beyond) 20 kHz, the energy above approximately 5 kHz has been largely neglected. Evidence is accruing that this high-frequency energy contains perceptual information relevant to speech and voice, including percepts of quality, localization, and intelligibility. The present research was an initial step in the long-range goal of characterizing high-frequency energy in singing voice and speech, with particular regard for its perceptual role and its potential for modification during voice and speech production. In this study, a database of high-fidelity recordings of talkers was created and used for a broad acoustical analysis and general characterization of high-frequency energy, as well as specific characterization of phoneme category, voice and speech intensity level, and mode of production (speech versus singing) by high-frequency energy content. Directionality of radiation of high-frequency energy from the mouth was also examined. The recordings were used for perceptual experiments wherein listeners were asked to discriminate between speech and voice samples that differed only in high-frequency energy content. Listeners were also subjected to gender discrimination tasks, mode-of-production discrimination tasks, and transcription tasks with samples of speech and singing that contained only high-frequency content. The combination of these experiments has revealed that (1) human listeners are able to detect very subtle level changes in high-frequency energy, and (2) human listeners are able to extract significant perceptual information from high-frequency energy.

  10. Exposure to high-frequency transient electromagnetic fields.

    Science.gov (United States)

    Skotte, J H

    1996-02-01

    The purpose of this study was to assess exposure to high-frequency transient (HFT) electromagnetic fields in occupational and residential environments. Exposure to HFT electromagnetic fields was measured with personal dosimeters for 301 volunteers (396 measurements) in periods of 24 h in both occupational and residential environments. The study included electrical utility workers (generation, transmission, distribution, substation), office and industrial workers, and people living near high-power transmission lines. The measure of exposure to HFT fields was specified as the proportion of time (parts per million) in which the electric field exceeds a nominal threshold level of 200 V.m-1 at 5-20 MHz. Recently the specification of the HFT channel of the dosimeter has been found to be incomplete; therefore a testing of the threshold level and the sensitivity to electromagnetic fields from radio-telephones was carried out. The percentage of measurements with a mean workday exposure above 0.1 ppm was 6.5-9.4% for the utility groups and 0.9% for all the nonwork measurements. It is likely that the use of radio-telephones has contributed significantly to the number of HFT events in some of the measurements, especially for the generation workers. The nominal threshold level of the dosimeter was found to vary considerably depending on the polarization of the field (20-400 V.m-1 at 13.56 MHz for one instrument). Generally speaking, HFT fields appeared infrequently. The workday exposure to HFT fields and 50 Hz magnetic fields ranked the groups differently. There is a need for developing instrumentation for HFT field measurements further.

  11. High-frequency broadband modulation of electroencephalographic spectra

    Directory of Open Access Journals (Sweden)

    Julie A Onton

    2009-12-01

    Full Text Available High-frequency cortical potentials in electroencephalographic (EEG scalp recordings have low amplitudes and may be confounded with scalp muscle activities. EEG data from an eyes-closed emotion imagination task were linearly decomposed using independent component analysis (ICA into maximally independent component (IC processes. Joint decomposition of IC log spectrograms into source- and frequency-independent modulator (IM processes revealed three distinct classes of IMs that separately modulated broadband high-frequency (~15-200 Hz power of brain, scalp muscle, and likely ocular motor IC processes. Multi-dimensional scaling revealed significant but spatially complex relationships between mean broadband brain IM effects and the valence of the imagined emotions. Thus, contrary to prevalent assumption, unitary modes of spectral modulation of frequencies encompassing the beta, gamma, and high gamma frequency ranges can be isolated from scalp-recorded EEG data and may be differentially associated with brain sources and cognitive activities.

  12. Project 8: Using Radio Frequencies to Measure the Neutrino Mass

    CERN Document Server

    Oblath, N S

    2011-01-01

    It is well known that the neutrino masses affect the shape of the energy spectrum of tritium beta-decay electrons. However, experiments have yet to measure that distortion. The Project 8 experiment proposes to measure the spectral distortion in a novel way: using radio-frequency techniques to detect and measure the energies of the beta-decay electrons. We plan on measuring the radiation created from the cyclotron motion of the electrons in a strong magnetic field. I will report on the status of a prototype that is designed to demonstrate single-electron detection at energies near the tritium endpoint, 18.6 keV. I will also discuss the possibilities for scaling up to a neutrino-mass experiment.

  13. The Influence of High-Frequency Envelope Information on Low-Frequency Vowel Identification in Noise.

    Science.gov (United States)

    Schubotz, Wiebke; Brand, Thomas; Kollmeier, Birger; Ewert, Stephan D

    2016-01-01

    Vowel identification in noise using consonant-vowel-consonant (CVC) logatomes was used to investigate a possible interplay of speech information from different frequency regions. It was hypothesized that the periodicity conveyed by the temporal envelope of a high frequency stimulus can enhance the use of the information carried by auditory channels in the low-frequency region that share the same periodicity. It was further hypothesized that this acts as a strobe-like mechanism and would increase the signal-to-noise ratio for the voiced parts of the CVCs. In a first experiment, different high-frequency cues were provided to test this hypothesis, whereas a second experiment examined more closely the role of amplitude modulations and intact phase information within the high-frequency region (4-8 kHz). CVCs were either natural or vocoded speech (both limited to a low-pass cutoff-frequency of 2.5 kHz) and were presented in stationary 3-kHz low-pass filtered masking noise. The experimental results did not support the hypothesized use of periodicity information for aiding low-frequency perception.

  14. The Influence of High-Frequency Envelope Information on Low-Frequency Vowel Identification in Noise.

    Directory of Open Access Journals (Sweden)

    Wiebke Schubotz

    Full Text Available Vowel identification in noise using consonant-vowel-consonant (CVC logatomes was used to investigate a possible interplay of speech information from different frequency regions. It was hypothesized that the periodicity conveyed by the temporal envelope of a high frequency stimulus can enhance the use of the information carried by auditory channels in the low-frequency region that share the same periodicity. It was further hypothesized that this acts as a strobe-like mechanism and would increase the signal-to-noise ratio for the voiced parts of the CVCs. In a first experiment, different high-frequency cues were provided to test this hypothesis, whereas a second experiment examined more closely the role of amplitude modulations and intact phase information within the high-frequency region (4-8 kHz. CVCs were either natural or vocoded speech (both limited to a low-pass cutoff-frequency of 2.5 kHz and were presented in stationary 3-kHz low-pass filtered masking noise. The experimental results did not support the hypothesized use of periodicity information for aiding low-frequency perception.

  15. Earless toads sense low frequencies but miss the high notes

    DEFF Research Database (Denmark)

    Womack, Molly C; Christensen-Dalsgaard, Jakob; Coloma, Luis A

    2017-01-01

    , four earless) within the Neotropical true toad family (Bufonidae). We found that species lacking middle ears are less sensitive to high-frequency sounds, however, low-frequency hearing and vibrational sensitivity are equivalent between eared and earless species. Furthermore, extratympanic hearing...

  16. Automated Screening for High-Frequency Hearing Loss

    NARCIS (Netherlands)

    Vlaming, M.S.M.G.; MacKinnon, R.C.; Jansen, M.; Moore, D.R.

    2014-01-01

    OBJECTIVE: Hearing loss at high frequencies produces perceptual difficulties and is often an early sign of a more general hearing loss. This study reports the development and validation of two new speech-based hearing screening tests in English that focus on detecting hearing loss at frequencies

  17. Scene content is predominantly conveyed by high spatial frequencies in scene-selective visual cortex.

    Science.gov (United States)

    Berman, Daniel; Golomb, Julie D; Walther, Dirk B

    2017-01-01

    In complex real-world scenes, image content is conveyed by a large collection of intertwined visual features. The visual system disentangles these features in order to extract information about image content. Here, we investigate the role of one integral component: the content of spatial frequencies in an image. Specifically, we measure the amount of image content carried by low versus high spatial frequencies for the representation of real-world scenes in scene-selective regions of human visual cortex. To this end, we attempted to decode scene categories from the brain activity patterns of participants viewing scene images that contained the full spatial frequency spectrum, only low spatial frequencies, or only high spatial frequencies, all carefully controlled for contrast and luminance. Contrary to the findings from numerous behavioral studies and computational models that have highlighted how low spatial frequencies preferentially encode image content, decoding of scene categories from the scene-selective brain regions, including the parahippocampal place area (PPA), was significantly more accurate for high than low spatial frequency images. In fact, decoding accuracy was just as high for high spatial frequency images as for images containing the full spatial frequency spectrum in scene-selective areas PPA, RSC, OPA and object selective area LOC. We also found an interesting dissociation between the posterior and anterior subdivisions of PPA: categories were decodable from both high and low spatial frequency scenes in posterior PPA but only from high spatial frequency scenes in anterior PPA; and spatial frequency was explicitly decodable from posterior but not anterior PPA. Our results are consistent with recent findings that line drawings, which consist almost entirely of high spatial frequencies, elicit a neural representation of scene categories that is equivalent to that of full-spectrum color photographs. Collectively, these findings demonstrate the

  18. Scene content is predominantly conveyed by high spatial frequencies in scene-selective visual cortex.

    Directory of Open Access Journals (Sweden)

    Daniel Berman

    Full Text Available In complex real-world scenes, image content is conveyed by a large collection of intertwined visual features. The visual system disentangles these features in order to extract information about image content. Here, we investigate the role of one integral component: the content of spatial frequencies in an image. Specifically, we measure the amount of image content carried by low versus high spatial frequencies for the representation of real-world scenes in scene-selective regions of human visual cortex. To this end, we attempted to decode scene categories from the brain activity patterns of participants viewing scene images that contained the full spatial frequency spectrum, only low spatial frequencies, or only high spatial frequencies, all carefully controlled for contrast and luminance. Contrary to the findings from numerous behavioral studies and computational models that have highlighted how low spatial frequencies preferentially encode image content, decoding of scene categories from the scene-selective brain regions, including the parahippocampal place area (PPA, was significantly more accurate for high than low spatial frequency images. In fact, decoding accuracy was just as high for high spatial frequency images as for images containing the full spatial frequency spectrum in scene-selective areas PPA, RSC, OPA and object selective area LOC. We also found an interesting dissociation between the posterior and anterior subdivisions of PPA: categories were decodable from both high and low spatial frequency scenes in posterior PPA but only from high spatial frequency scenes in anterior PPA; and spatial frequency was explicitly decodable from posterior but not anterior PPA. Our results are consistent with recent findings that line drawings, which consist almost entirely of high spatial frequencies, elicit a neural representation of scene categories that is equivalent to that of full-spectrum color photographs. Collectively, these findings

  19. High Frequency Radar Locations in the United States as of February 2016.

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset show the point locations of High Frequency (HF) radar systems across the US. HF radars measure the speed and direction of ocean surface currents in near...

  20. High Frequency QPOs due to Black Hole Spin

    Science.gov (United States)

    Kazanas, Demos; Fukumura, K.

    2009-01-01

    We present detailed computations of photon orbits emitted by flares at the innermost stable circular orbit (ISCO) of accretion disks around rotating black holes. We show that for sufficiently large spin parameter, i.e. a > 0.94 M, flare a sufficient number of photons arrive at an observer after multiple orbits around the black hole, to produce an "photon echo" of constant lag, i.e. independent of the relative phase between the black hole and the observer, of T approximates 14 M. This constant time delay, then, leads to a power spectrum with a QPO at a frequency nu approximates 1/14M, even for a totally random ensemble of such flares. Observation of such a QPO will provide incontrovertible evidence for the high spin of the black hole and a very accurate, independent, measurement of its mass.

  1. The wave buoy analogy - estimating high-frequency wave excitations

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2008-01-01

    The paper deals with the wave buoy analogy where a ship is considered as a wave buoy, so that measured ship responses are used as a basis to estimate wave spectra and associated sea state parameters. The study presented follows up on a previous paper, Nielsen [Nielsen UD. Response-based estimation...... of sea state parameters — influence of filtering. Ocean Engineering 2007;34:1797–810.], where time series of ship responses were generated from a known wave spectrum for the purpose of the inverse process — the estimation of the underlying wave excitations. Similar response generations and vice versa...... be estimated reasonably well, even considering high-frequency wave components of a wind sea wave spectrum....

  2. High frequency techniques an introduction to RF and microwave engineering

    CERN Document Server

    White, Joseph F

    2004-01-01

    A practical guide for today's wireless engineerHigh Frequency Techniques: An Introduction to RF and Microwave Engineering is a clearly written classical circuit and field theory text illustrated with modern computer simulation software. The book's ten chapters cover: *The origins and current uses of wireless transmission *A review of AC analysis, Kirchhoff's laws, RLC elements, skin effect, and introduction to the use of computer simulation software*Resonators, Q definitions, and Q-based impedance matching *Transmission lines, waves, VSWR, reflection phenomena, Fano's reflection bandwidth limits, telegrapher, and impedance transformation equations*Development and in-depth use of the Smith Chart *Matrix algebra with Z, Y, ABCD, S, and T matrix applications*An unusually thorough introduction to electromagnetic field theory, step-by-step development of vector calculus, Maxwell's equations, waveguides, propagation, and antennas*Backward wave, branch line, rat race and Wilkinson couplers, impedance measurements, a...

  3. Excitation and Ionisation dynamics in high-frequency plasmas

    Science.gov (United States)

    O'Connell, D.

    2008-07-01

    Non-thermal low temperature plasmas are widely used for technological applications. Increased demands on plasma technology have resulted in the development of various discharge concepts based on different power coupling mechanisms. Despite this, power dissipation mechanisms in these discharges are not yet fully understood. Of particular interest are low pressure radio-frequency (rf) discharges. The limited understanding of these discharges is predominantly due to the complexity of the underlying mechanisms and difficult diagnostic access to important parameters. Optical measurements are a powerful diagnostic tool offering high spatial and temporal resolution. Optical emission spectroscopy (OES) provides non-intrusive access, to the physics of the plasma, with comparatively simple experimental requirements. Improved advances in technology and modern diagnostics now allow deeper insight into fundamental mechanisms. In low pressure rf discharges insight into the electron dynamics within the rf cycle can yield vital information. This requires high temporal resolution on a nano-second time scale. The optical emission from rf discharges exhibits temporal variations within the rf cycle. These variations are particularly strong, in for example capacitively coupled plasmas (CCPs), but also easily observable in inductively coupled plasmas (ICPs), and can be exploited for insight into power dissipation. Interesting kinetic and non-linear coupling effects are revealed in capacitive systems. The electron dynamics exhibits a complex spatio-temporal structure. Excitation and ionisation, and, therefore, plasma sustainment is dominated through directed energetic electrons created through the dynamics of the plasma boundary sheath. In the relatively simple case of an asymmetric capacitively coupled rf plasma the complexity of the power dissipation is exposed and various mode transitions can be clearly observed and investigated. At higher pressure secondary electrons dominate the

  4. Instrumentation for high-frequency meteorological observations from research vessel

    Digital Repository Service at National Institute of Oceanography (India)

    VijayKumar, K.; Khalap, S.; Mehra, P.

    Ship provides an attractive platform from which high-frequency meteorological observations (e.g., wind components, water vapor density, and air temperature) can be made accurately. However, accurate observations of meteorological variables depend...

  5. Music students: conventional hearing thresholds and at high frequencies

    National Research Council Canada - National Science Library

    Lüders, Débora; Gonçalves, Cláudia Giglio de Oliveira; Lacerda, Adriana Bender de Moreira; Ribas, Ângela; Conto, Juliana de

    2014-01-01

    .... To analyze the hearing thresholds from 250 Hz to 16,000 Hz in a group of music students and compare them to a non-musician group in order to determine whether high-frequency audiometry is a useful...

  6. BIOLOGICAL EFFECTS OF HIGH-FREQUENCY ELECTROMAGNETIC WAVES

    Science.gov (United States)

    In this report the author discusses the influence of high-frequency electromagnetic waves on living matter, especially in the field of microwaves. He...of electromagnetic waves . Symptoms of damage are listed and methods of protection discussed.

  7. High-frequency matrix converter with square wave input

    Science.gov (United States)

    Carr, Joseph Alexander; Balda, Juan Carlos

    2015-03-31

    A device for producing an alternating current output voltage from a high-frequency, square-wave input voltage comprising, high-frequency, square-wave input a matrix converter and a control system. The matrix converter comprises a plurality of electrical switches. The high-frequency input and the matrix converter are electrically connected to each other. The control system is connected to each switch of the matrix converter. The control system is electrically connected to the input of the matrix converter. The control system is configured to operate each electrical switch of the matrix converter converting a high-frequency, square-wave input voltage across the first input port of the matrix converter and the second input port of the matrix converter to an alternating current output voltage at the output of the matrix converter.

  8. High-Frequency Microwave Processing of Materials Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Conducts research on high-frequency microwave processing of materials using a highpower, continuous-wave (CW), 83-GHz, quasi-optical beam system for rapid,...

  9. High frequency study of nutrient fluxes variability in a small river

    Science.gov (United States)

    Zongo, S. B.; Schmitt, F. G.

    2012-04-01

    We consider here high frequency nutrient fluxes recorded during two one month duration campaigns in 2010 and 2011 in the Wimereux river (North of France). During these campaigns, the river flow is recorded every 10 minutes, simultaneously with NO3, NH4, PO4 and COT data. High frequency fluxes are computed. We first compare these high frequency estimations with low frequency (1 measurement every month) estimations in order to quantify the error in the latter. We also consider the pdf of the ratio of high frequency fluxes ("true" values) to low frequency estimation. We finally consider the scaling properties of the fluctuations of the nutrient data, flow data, and of the fluxes. This study was supported by a grant from Agence de l'Eau Artois Picardie.

  10. Gender & High Frequency vs. Low Frequency tasks in a context of Joint-Liability Incentives.

    OpenAIRE

    Marianne Bernatzky; José María Cabrera; Alejandro Cid

    2014-01-01

    We study the impact of high and low frequency incentives in a joint-liability framework on six academic outcomes of undergraduate students using a randomized field experiment. As recently documented in health literature, incentives to exercise are effective in developing healthy habits. Therefore, we design groups of three students and provide a premium to the homework’s grade if all the members of the group (three) meet some requirements. We investigate how the frequency of these take home t...

  11. Music students: conventional hearing thresholds and at high frequencies

    OpenAIRE

    Lüders,Débora; Gonçalves, Cláudia Giglio de Oliveira; de Moreira Lacerda, Adriana Bender; Ribas,Ângela; Conto,Juliana de

    2014-01-01

    INTRODUCTION: Research has shown that hearing loss in musicians may cause difficulty in timbre recognition and tuning of instruments. AIM: To analyze the hearing thresholds from 250 Hz to 16,000 Hz in a group of music students and compare them to a non-musician group in order to determine whether high-frequency audiometry is a useful tool in the early detection of hearing impairment. METHODS: Study design was a retrospective observational cohort. Conventional and high-frequency audio...

  12. Efficacy of Conventional and High-Frequency Ventilation at Altitude

    Science.gov (United States)

    1988-12-01

    evacuation; Mechanical ventilation ;--andL If.’jJI t’ 06 I 12 i ~High-Frequency ventilation ’& ~.~.- 19 ABSTRACT (Continue on reverse If neesry and identify by...The inspired gas and the subsequent rate of appearance of these gases in arterial blood were monitored. With conventional mechanical ventilation (CMV...AND HIGH-FREQUENCY VENTILATION AT ALTITUDE INTRODUCTION The logistics of aeromedical evacuation of patients requiring mechanical ventilation is

  13. Testing the efficiency of high-frequency foreign exchange market

    Directory of Open Access Journals (Sweden)

    Václav Mastný

    2004-01-01

    Full Text Available This paper deals with the efficiency of the high-frequency foreign exchange market. The objective of this paper is to investigate whether standard statistical tests give the same results for time series resampled at intervals of 15.30 and 60 min. The data used for the purpose of this paper contain major currency pairs such as EUR/USD, GBP/USD and JPY/USD. The results of statistical tests indicate that the high frequency intervals (15-minute are not random and should not be considered independent. On the other hand, tests with lower frequency rates (30 and 60 min indicate rising randomness of the market.

  14. Network Analyses for Space-Time High Frequency Wind Data

    Science.gov (United States)

    Laib, Mohamed; Kanevski, Mikhail

    2017-04-01

    Recently, network science has shown an important contribution to the analysis, modelling and visualization of complex time series. Numerous existing methods have been proposed for constructing networks. This work studies spatio-temporal wind data by using networks based on the Granger causality test. Furthermore, a visual comparison is carried out with several frequencies of data and different size of moving window. The main attention is paid to the temporal evolution of connectivity intensity. The Hurst exponent is applied on the provided time series in order to explore if there is a long connectivity memory. The results explore the space time structure of wind data and can be applied to other environmental data. The used dataset presents a challenging case study. It consists of high frequency (10 minutes) wind data from 120 measuring stations in Switzerland, for a time period of 2012-2013. The distribution of stations covers different geomorphological zones and elevation levels. The results are compared with the Person correlation network as well.

  15. High Frequency Longitudinal Damped Vibrations of a Cylindrical Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    Mihai Valentin Predoi

    2014-01-01

    Full Text Available Ultrasonic piezoelectric transducers used in classical nondestructive testing are producing in general longitudinal vibrations in the MHz range. A simple mechanical model of these transducers would be very useful for wave propagation numerical simulations, avoiding the existing complicated models in which the real components of the transducer are modeled by finite elements. The classical model for longitudinal vibrations is not adequate because the generated longitudinal wave is not dispersive, the velocity being the same at any frequency. We have adopted the Rayleigh-Bishop model, which avoids these limitations, even if it is not converging to the first but to the second exact longitudinal mode in an elastic rod, as obtained from the complicated Pochhammer-Chree equations. Since real transducers have significant vibrations damping, we have introduced a damping term in the Rayleigh-Bishop model, increasing the imaginary part and keeping almost identical real part of the wavenumber. Common transducers produce amplitude modulated signals, completely attenuated after several periods. This can be modeled by two close frequencies, producing a “beat” phenomenon, superposed on the high damping. For this reason, we introduce a two-rod Rayleigh-Bishop model with damping. Agreement with measured normal velocity on the transducer free surface is encouraging for continuation of the research.

  16. Technique for Performing Dielectric Property Measurements at Microwave Frequencies

    Science.gov (United States)

    Barmatz, Martin B. (Inventor); Jackson, Henry W. (Inventor)

    2014-01-01

    A method, system, apparatus, and computer readable medium has been provided with the ability to obtain a complex permittivity dielectric or a complex permeability micron of a sample in a cavity. One or more complex-valued resonance frequencies f(sub m) of the cavity, wherein each f(sub m) is a measurement, are obtained. Maxwell's equations are solved exactly for dielectric, and/or micron, using the f(sub m) as known quantities, thereby obtaining the dielectric and/or micron of the sample.

  17. Nondestructive Measurement of Momentum Transfer Collision Frequency for Low Temperature Combustion Plasma

    Directory of Open Access Journals (Sweden)

    Douglas Letsholathebe

    2014-01-01

    Full Text Available Accurately measured momentum transfer collision frequency and electron density for fire plasma enable correct simulation of electromagnetic wave propagation in the medium. The simulation is essential for designing high-performance systems suitable for the environment. Despite this, momentum transfer collision frequency for fire plumes has always been an estimated quantity and/or crudely determined. There are anecdotal reports of severe line-of-sight (LOS radio frequency signal degradation on firegrounds. The problem has implications on safety of fire-fighters during wildfire suppression hence the need of high performance communication systems. In the experiment, a nonintrusive and direct method for measuring momentum transfer collision frequency in a fire plume was carried out. Using an automatic network analyser, x-band microwaves were caused to propagate combustion zones of eucalyptus and grass litter fires to measure the flames, scattering parameters. The parameters were then used to determine average collision frequencies for the plumes. The average collision frequencies for the eucalyptus and grass fire plumes were measured to be 5.84×1010 and 5.92×1010 rad/s, respectively.

  18. The role of high-frequency audiometry in early detection of ototoxicity

    NARCIS (Netherlands)

    Dreschler, W. A.; vd Hulst, R. J.; Tange, R. A.; Urbanus, N. A.

    1985-01-01

    Ototoxicity is one of the unwanted side-effects of a number of medical drugs. As ototoxicity appears to be most pronounced in the higher frequencies, it can be assessed at an earlier stage by using high-frequency audiometry from 8 to 20 kHz. We have investigated the precision of these measurements.

  19. High-frequency underwater plasma discharge application in antibacterial activity

    Science.gov (United States)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U.; Mongre, R. K.; Jeong, D. K.; Suresh, R.; Lee, H. J.

    2017-03-01

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli ( E. coli) by generating high-frequency, high-voltage, oxygen (O2) injected and hydrogen peroxide (H2O2) added discharge in water was achieved. The effect of H2O2 dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H2O2 addition with O2 injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH•, H, and O). Interestingly, the results demonstrated that O2 injected and H2O2 added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.

  20. High-frequency underwater plasma discharge application in antibacterial activity

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, M. W.; Choi, S.; Lyakhov, K.; Shaislamov, U. [Jeju National University, Department of Nuclear and Energy Engineering (Korea, Republic of); Mongre, R. K.; Jeong, D. K. [Jeju National University, Faculty of Biotechnology (Korea, Republic of); Suresh, R.; Lee, H. J., E-mail: hjlee@jejunu.ac.kr [Jeju National University, Department of Nuclear and Energy Engineering (Korea, Republic of)

    2017-03-15

    Plasma discharge is a novel disinfection and effectual inactivation approach to treat microorganisms in aqueous systems. Inactivation of Gram-negative Escherichia coli (E. coli) by generating high-frequency, high-voltage, oxygen (O{sub 2}) injected and hydrogen peroxide (H{sub 2}O{sub 2}) added discharge in water was achieved. The effect of H{sub 2}O{sub 2} dose and oxygen injection rate on electrical characteristics of discharge and E. coli disinfection has been reported. Microbial log reduction dependent on H{sub 2}O{sub 2} addition with O{sub 2} injection was observed. The time variation of the inactivation efficiency quantified by the log reduction of the initial E. coli population on the basis of optical density measurement was reported. The analysis of emission spectrum recorded after discharge occurrence illustrated the formation of oxidant species (OH{sup •}, H, and O). Interestingly, the results demonstrated that O{sub 2} injected and H{sub 2}O{sub 2} added, underwater plasma discharge had fabulous impact on the E. coli sterilization. The oxygen injection notably reduced the voltage needed for generating breakdown in flowing water and escalated the power of discharge pulses. No impact of hydrogen peroxide addition on breakdown voltage was observed. A significant role of oxidant species in bacterial inactivation also has been identified. Furthermore the E. coli survivability in plasma treated water with oxygen injection and hydrogen peroxide addition drastically reduced to zero. The time course study also showed that the retardant effect on E. coli colony multiplication in plasma treated water was favorable, observed after long time. High-frequency underwater plasma discharge based biological applications is technically relevant and would act as baseline data for the development of novel antibacterial processing strategies.

  1. Frequency stability measurement of a transfer-cavity-stabilized diode laser by using an optical frequency comb

    Science.gov (United States)

    Uetake, S.; Matsubara, K.; Ito, H.; Hayasaka, K.; Hosokawa, M.

    2009-10-01

    We report results of frequency stability measurements of an extended cavity diode laser (ECDL) whose frequency is stabilized by a non-evacuated scanning transfer cavity. The transfer cavity is locked to a commercial frequency stabilized helium-neon laser. Frequency stability is measured by use of an optical frequency comb. The environmental perturbations (variations of temperature, air pressure, and humidity) are also simultaneously measured. The observed frequency drift of the ECDL is well explained by environmental perturbations. An atmospheric pressure variation, which is difficult to control with a non-evacuated cavity, is mainly affected to the frequency stability. Thus we put the cavity into a simple O-ring sealed (non-evacuated) tube. With this simple O-ring sealed tube, the frequency drift is reduced by a factor of 3, and the Allan variance reaches a value of 2.4×10-10, corresponds to the frequency stability of 83 kHz, at the average time of 3000 s. Since the actual frequency drift is well estimated by simultaneous measurement of the ambient temperature, pressure, and humidity, a feed-forward compensation of frequency drifts is also feasible in order to achieve a higher frequency stability with a simple non-evacuated transfer cavity.

  2. Characteristics of a piezoresistive accelerometer in high frequency, high shock environments

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, V.I.; Davie, N.T.; Brown, F.A.

    1993-12-31

    The characteristics of a piezoresistive accelerometer in shock environments are being studied at Sandia National Laboratories in the Mechanical Shock Testing Laboratory. A Hopkinson bar capability has been developed to extend our understanding of the piezoresistive accelerometer with and without mechanical isolation in the high frequency, high shock environments where measurements are being made. Two different Hopkinson bar materials are being used: titanium and beryllium. The characteristics of the piezoresistive accelerometer for frequencies of DC-10 kHz and shock magnitudes of up to 4,000 g as determined from measurements with a titanium Hopkinson bar are presented. The SNL uniaxial shock isolation technique has demonstrated acceptable characteristics for a temperature range of {minus}50{degree}F to +186{degree}F and a frequency bandwidth of DC to 10 kHz. These characteristics have been verified by the calibration of the Hopkinson bar used for accelerometer testing. The beryllium Hopkinson bar configuration is described. Preliminary characteristics of the piezoresistive accelerometer at a nominal shock level of 17,000 g for a frequency range of DC-50 kHz are presented.

  3. High frequency guided wave propagation in monocrystalline silicon wafers

    Science.gov (United States)

    Pizzolato, Marco; Masserey, Bernard; Robyr, Jean-Luc; Fromme, Paul

    2017-04-01

    Monocrystalline silicon wafers are widely used in the photovoltaic industry for solar panels with high conversion efficiency. The cutting process can introduce micro-cracks in the thin wafers and lead to varying thickness. High frequency guided ultrasonic waves are considered for the structural monitoring of the wafers. The anisotropy of the monocrystalline silicon leads to variations of the wave characteristics, depending on the propagation direction relative to the crystal orientation. Full three-dimensional Finite Element simulations of the guided wave propagation were conducted to visualize and quantify these effects for a line source. The phase velocity (slowness) and skew angle of the two fundamental Lamb wave modes (first anti-symmetric mode A0 and first symmetric mode S0) for varying propagation directions relative to the crystal orientation were measured experimentally. Selective mode excitation was achieved using a contact piezoelectric transducer with a custom-made wedge and holder to achieve a controlled contact pressure. The out-of-plane component of the guided wave propagation was measured using a noncontact laser interferometer. Good agreement was found with the simulation results and theoretical predictions based on nominal material properties of the silicon wafer.

  4. Algorithmic and high-frequency trading in Borsa Istanbul

    Directory of Open Access Journals (Sweden)

    Oguz Ersan

    2016-12-01

    Full Text Available This paper investigates the levels of algorithmic trading (AT and high-frequency trading (HFT in an emerging market, Borsa Istanbul (BIST, utilizing a dataset of 354 trading days between January 2013 and May 2014. We find an upward trend in AT by using common proxies: number of messages per minute and algo_trad of Hendershott et al. (2011. Mean algo_trad for BIST 100 index constituents varies between −18 and −13 which is parallel to 2003–2005 levels of NASDAQ large cap stocks. Initially, we measure HFT involvement by detecting linked messages as in the way proposed in Hasbrouck and Saar (2013. Next, we propose an extended HFT measure which captures various HFT strategies. This measure attributes approximately 6% of the orders to HFT. HFT involvement is higher in large orders (11.96%, in orders submitted by portfolio/fund management firms (10.40%, after improvement of BIST's order submission platform and tick size reduction for certain stocks.

  5. Advanced waveforms and frequency with spinal cord stimulation: burst and high-frequency energy delivery.

    Science.gov (United States)

    Pope, Jason E; Falowski, Steven; Deer, Tim R

    2015-07-01

    In recent years, software development has been key to the next generation of neuromodulation devices. In this review, we will describe the new strategies for electrical waveform delivery for spinal cord stimulation. A systematic literature review was performed using bibliographic databases, limited to the English language and human data, between 2010 and 2014. The literature search yielded three articles on burst stimulation and four articles on high-frequency stimulation. High-frequency and burst stimulation may offer advantages over tonic stimulation, as data suggest improved patient tolerance, comparable increase in function and possible success with a subset of patients refractory to tonic spinal cord stimulation. High-frequency and burst stimulation are new ways to deliver energy to the spinal cord that may offer advantages over tonic stimulation. These may offer new salvage strategies to mitigate spinal cord stimulation failure and improve cost-effectiveness by reducing explant rate.

  6. Laser heterodyne interferometric signal processing method based on rising edge locking with high frequency clock signal.

    Science.gov (United States)

    Zhang, Enzheng; Chen, Benyong; Yan, Liping; Yang, Tao; Hao, Qun; Dong, Wenjun; Li, Chaorong

    2013-02-25

    A novel phase measurement method composed of the rising-edge locked signal processing and the digital frequency mixing is proposed for laser heterodyne interferometer. The rising-edge locked signal processing, which employs a high frequency clock signal to lock the rising-edges of the reference and measurement signals, not only can improve the steepness of the rising-edge, but also can eliminate the error counting caused by multi-rising-edge phenomenon in fringe counting. The digital frequency mixing is realized by mixing the digital interference signal with a digital base signal that is different from conventional frequency mixing with analogue signals. These signal processing can improve the measurement accuracy and enhance anti-interference and measurement stability. The principle and implementation of the method are described in detail. An experimental setup was constructed and a series of experiments verified the feasibility of the method in large displacement measurement with high speed and nanometer resolution.

  7. Frequency characteristics of amplitude and phase of oscillating bubble systems in a closed measuring cell.

    Science.gov (United States)

    Kovalchuk, V I; Krägel, J; Makievski, A V; Loglio, G; Ravera, F; Liggieri, L; Miller, R

    2002-08-15

    The amplitude- and phase-frequency characteristics of oscillating bubble systems with a closed measuring cell are analyzed. The shape of the frequency characteristics is qualitatively different for bubbles smaller or larger than a hemisphere, respectively, and also for diluted and concentrated surfactant solutions. Moreover, the presence of a surfactant in the solution strongly influences the characteristic frequencies of the system. The experiments performed under ground and microgravity conditions show a good qualitative agreement with theoretically predicted amplitude- and phase-frequency characteristics and confirm the adequacy of the proposed theory. The comparison of high-frequency limits of the surface dilatational elasticity with the theoretical Gibbs elasticities calculated according to the respective adsorption isotherm shows good agreement for small surfactant concentrations. At higher concentrations large discrepancies are observed which can possibly be explained by the violation of the linearity condition for the surface layer.

  8. Measurement of the B$_{d}^{0}$ meson oscillation frequency

    CERN Document Server

    Acciarri, M; Aguilar-Benítez, M; Ahlen, S P; Alpat, B; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alverson, G; Alviggi, M G; Ambrosi, G; Anderhub, H; Andreev, V P; Angelescu, T; Antreasyan, D; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Baksay, L; Ball, R C; Banerjee, S; Banicz, K; Barillère, R; Barone, L; Bartalini, P; Baschirotto, A; Basile, M; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Biasini, M; Biland, A; Bilei, G M; Blaising, J J; Blyth, S C; Bobbink, Gerjan J; Böck, R K; Böhm, A; Borgia, B; Boucham, A; Bourilkov, D; Bourquin, Maurice; Boutigny, D; Brambilla, Elena; Branson, J G; Brigljevic, V; Brock, I C; Buijs, A; Burger, J D; Burger, W J; Busenitz, J K; Buytenhuijs, A O; Cai, X D; Campanelli, M; Capell, M; Cara Romeo, G; Caria, M; Carlino, G; Cartacci, A M; Casaus, J; Castellini, G; Castello, R; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada-Canales, M; Cesaroni, F; Chamizo-Llatas, M; Chan, A; Chang, Y H; Chaturvedi, U K; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chen, M; Chiefari, G; Chien, C Y; Choi, M T; Cifarelli, Luisa; Cindolo, F; Civinini, C; Clare, I; Clare, R; Cohn, H O; Coignet, G; Colijn, A P; Colino, N; Costantini, S; Cotorobai, F; de la Cruz, B; Csilling, Akos; Dai, T S; D'Alessandro, R; De Asmundis, R; De Boeck, H; Degré, A; Deiters, K; Denes, P; De Notaristefani, F; DiBitonto, Daryl; Diemoz, M; Van Dierendonck, D N; Di Lodovico, F; Dionisi, C; Dittmar, Michael; Dominguez, A; Doria, A; Dorne, I; Dova, M T; Drago, E; Duchesneau, D; Duinker, P; Durán, I; Dutta, S; Easo, S; Efremenko, Yu V; El-Mamouni, H; Engler, A; Eppling, F J; Erné, F C; Ernenwein, J P; Extermann, Pierre; Fabre, M; Faccini, R; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, Marta; Ferguson, T; Fernández, D; Ferroni, F; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, Frank; Fisher, P H; Forconi, G; Fredj, L; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; Gau, S S; Gentile, S; Gerald, J; Gheordanescu, N; Giagu, S; Goldfarb, S; Goldstein, J; Gong, Z F; Gougas, Andreas; Gratta, Giorgio; Grünewald, M W; Gupta, V K; Gurtu, A; Gutay, L J; Hangarter, K; Hartmann, B; Hasan, A; Hebbeker, T; Hervé, A; Van Hoek, W C; Hofer, H; Hoorani, H; Hou, S R; Hu, G; Ilyas, M M; Innocente, Vincenzo; Janssen, H; Jin, B N; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kasser, A; Khan, R A; Kamyshkov, Yu A; Kapinos, P; Kapustinsky, J S; Karyotakis, Yu; Kaur, M; Kienzle-Focacci, M N; Kim, D; Kim, J K; Kim, S C; Kim, Y G; Kinnison, W W; Kirkby, A; Kirkby, D; Kirkby, Jasper; Kiss, D; Kittel, E W; Klimentov, A; König, A C; Korolko, I; Koutsenko, V F; Krämer, R W; Kramer, T; Krenz, W; Kuijten, H; Kunin, A; Ladrón de Guevara, P; Landi, G; Lapoint, C; Lassila-Perini, K M; Laurikainen, P; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Lee Jae Sik; Lee, K Y; Leggett, C; Le Goff, J M; Leiste, R; Lenti, M; Leonardi, E; Levchenko, P M; Li Chuan; Lieb, E H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lu, W; Lü, Y S; Lübelsmeyer, K; Luci, C; Luckey, D; Ludovici, L; Luminari, L; Lustermann, W; Ma Wen Gan; Macchiolo, A; Maity, M; Majumder, G; Malgeri, L; Malinin, A; Maña, C; Mangla, S; Marchesini, P A; Marin, A; Martin, J P; Marzano, F; Massaro, G G G; Mazumdar, K; McNally, D; Mele, S; Merola, L; Meschini, M; Metzger, W J; Von der Mey, M; Mi, Y; Mihul, A; Van Mil, A J W; Mirabelli, G; Mnich, J; Monteleoni, B; Moore, R; Morganti, S; Mount, R; Müller, S; Muheim, F; Nagy, E; Nahn, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Nippe, A; Nowak, H; Organtini, G; Ostonen, R; Pandoulas, D; Paoletti, S; Paolucci, P; Park, H K; Pascale, G; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, Felicitas; Peach, D; Pei, Y J; Pensotti, S; Perret-Gallix, D; Petrak, S; Pevsner, A; Piccolo, D; Pieri, M; Pinto, J C; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Postema, H; Produit, N; Prokofev, D; Prokofiev, D O; Raghavan, R; Rahal-Callot, G; Rancoita, P G; Rattaggi, M; Raven, G; Razis, P A; Read, K; Ren, D; Rescigno, M; Reucroft, S; Van Rhee, T; Riemann, S; Riemers, B C; Riles, K; Rind, O; Ro, S; Robohm, A; Rodin, J; Rodríguez-Calonge, F J; Roe, B P; Röhner, S; Romero, L; Rosier-Lees, S; Rosselet, P; Van Rossum, W; Roth, S; Rubio, Juan Antonio; Rykaczewski, H; Salicio, J; Sánchez, E; Santocchia, A; Sarakinos, M E; Sarkar, S; Sassowsky, M; Sauvage, G; Schäfer, C; Shchegelskii, V; Schmidt-Kärst, S; Schmitz, D; Schmitz, P; Schneegans, M; Schöneich, B; Scholz, N; Schopper, Herwig Franz; Schotanus, D J; Schwenke, J; Schwering, G; Sciacca, C; Sciarrino, D; Sens, Johannes C; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shukla, J; Shumilov, E; Shvorob, A V; Siedenburg, T; Son, D; Sopczak, André; Soulimov, V; Smith, B; Spillantini, P; Steuer, M; Stickland, D P; Sticozzi, F; Stone, H; Stoyanov, B; Strässner, A; Strauch, K; Sudhakar, K; Sultanov, G G; Sun, L Z; Susinno, G F; Suter, H; Swain, J D; Tang, X W; Tauscher, Ludwig; Taylor, L; Ting, Samuel C C; Ting, S M; Tonisch, F; Tonutti, M; Tonwar, S C; Tóth, J; Tully, C; Tuchscherer, H; Tung, K L; Ulbricht, J; Uwer, U; Valente, E; Van de Walle, R T; Vesztergombi, G; Vetlitskii, I; Viertel, Gert M; Vivargent, M; Völkert, R; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Vorvolakos, A; Wadhwa, M; Wallraff, W; Wang, J C; Wang, X L; Wang, Y F; Wang, Z M; Weber, A; Wittgenstein, F; Wu, S X; Wynhoff, S; Xu, J; Xu, Z Z; Yang, B Z; Yang, C G; Yao, X Y; Ye, J B; Yeh, S C; You, J M; Zalite, A; Zalite, Yu; Zemp, P; Zeng, Y; Zhang, Z; Zhang, Z P; Zhou, B; Zhou, Y; Zhu, G Y; Zhu, R Y; Zichichi, Antonino

    1996-01-01

    Time-dependent \\Bd-\\Bbd\\ mixing is studied using 1.5 million hadronic Z decays collected by L3. Semileptonic B decays are selected by requiring at least one reconstructed lepton in both thrust hemispheres. Charge correlations between the tagged leptons are studied as a function of proper time. The proper time of the b-hadron decay is measured by reconstructing the production and decay vertices using a silicon microvertex detector. The measured \\Bd\\ meson oscillation frequency corresponds to a mass difference \\Dmd\\ between the two \\Bd\\ mass eigenstates of \\begin{displaymath} \\Dmd = \\left( 0.496 ^{+ 0.055}_{- 0.051}\\ \\mathrm{(stat)} \\pm{ 0.043}\\ \\mathrm{(syst)} \\right)\\ \\mathrm{ps}^{-1}. \\end{displaymath}

  9. Adequacy of Frequency Reserves for High Wind Power Generation

    DEFF Research Database (Denmark)

    Das, Kaushik; Litong-Palima, Marisciel; Maule, Petr

    2017-01-01

    are developed through this methodology. Furthermore, the probability of reducing this frequency containment reserve requirement is investigated through this methodology with activation of different volumes and speed of frequency restoration reserve. Wind power generation for 2020 and 2030 scenarios......In this article, a new methodology is developed to assess the adequacy of frequency reserves to handle power imbalances caused by wind power forecast errors. The goal of this methodology is to estimate the adequate volume and speed of activation of frequency reserves required to handle power...... imbalances caused due to high penetration of wind power. An algorithm is proposed and developed to estimate the power imbalances due to wind power forecast error following activation of different operating reserves. Frequency containment reserve requirements for mitigating these power imbalances...

  10. Extending the frequency range of free-field reciprocity calibration of measurement microphones to frequencies up to 150 kHz

    DEFF Research Database (Denmark)

    Barrera Figueroa, Salvador; Torras Rosell, Antoni; Jacobsen, Finn

    2013-01-01

    Measurement microphones are typically calibrated in a free field at frequencies up to 50 kHz. This is a sufficiently high frequency for the most sound measurement applications related with noise assessment. However, other applications such as the measurement of noise emitted by ultrasound cleaning...... machines and failure detection in aeronautic structures require that the sensitivity of the microphone is known at frequencies up to 150 kHz. Another area of particular interest is the investigation of the perception mechanisms of ultrasound. In any of these applications, it is of fundamental importance...... to establish a well-defined traceability chain to support the measurement results. In order to extend the frequency range of free-field calibration the measurement system and measurement methods must undergo a series of changes and adaptations including the type of excitation signal, techniques for eliminating...

  11. An application of uncertain numbers in radio frequency power measurement

    Science.gov (United States)

    Hall, B. D.

    2009-06-01

    The uncertain-numbers method (Hall B D 2006 Metrologia 43 L56-61) is an alternative computational procedure to the Law of Propagation of Uncertainty (LPU) described in the Guide to the Expression of Uncertainty in Measurement. One advantage of the method is that data processing can be carried out in an arbitrary series of steps and much of the mathematical analysis normally associated with the LPU can be automated by software. This has applications for measuring systems, which are modular in design and use internal data processing to apply corrections to raw data. Several scenarios involving radio frequency power measurements are used to illustrate the new method in this context. The scenarios show something of the difficulty inherent in calculating uncertainty for modern measurement systems and in particular highlight the occurrence of systematic errors arising from internal instrument correction factors. Such errors introduce correlation to a series of measurements and must be handled with care when functions of results, such as means, differences and ratios, are required.

  12. Compression Frequency Choice for Compression Mass Gauge Method and Effect on Measurement Accuracy

    Science.gov (United States)

    Fu, Juan; Chen, Xiaoqian; Huang, Yiyong

    2013-12-01

    It is a difficult job to gauge the liquid fuel mass in a tank on spacecrafts under microgravity condition. Without the presence of strong buoyancy, the configuration of the liquid and gas in the tank is uncertain and more than one bubble may exist in the liquid part. All these will affect the measure accuracy of liquid mass gauge, especially for a method called Compression Mass Gauge (CMG). Four resonance resources affect the choice of compression frequency for CMG method. There are the structure resonance, liquid sloshing, transducer resonance and bubble resonance. Ground experimental apparatus are designed and built to validate the gauging method and the influence of different compression frequencies at different fill levels on the measurement accuracy. Harmonic phenomenon should be considered during filter design when processing test data. Results demonstrate the ground experiment system performances well with high accuracy and the measurement accuracy increases as the compression frequency climbs in low fill levels. But low compression frequencies should be the better choice for high fill levels. Liquid sloshing induces the measurement accuracy to degrade when the surface is excited to wave by external disturbance at the liquid natural frequency. The measurement accuracy is still acceptable at small amplitude vibration.

  13. Resonant frequencies and Q factors of dielectric parallelepipeds by measurement and by FDTD

    Energy Technology Data Exchange (ETDEWEB)

    Trueman, C.W. [Concordia Univ., Montreal, Quebec (Canada); Mishra, S.R.; Larose, C.L. [David Florida Lab., Ottawa (Canada)] [and others

    1994-12-31

    This paper describes the measurement and computation of the resonant frequencies and the associated Q factors of dielectric parallelepipeds made of high-permittivity, low-loss ceramic materials. Each resonance peak is measured separately with a fine frequency step. A curve-fitting method is used to accurately estimate the resonant frequency and 3 dB bandwidth from the somewhat noisy measured data. The finite-difference time-domain method is used to compute the initial portion of the backscattered field due to a Gaussian pulse plane wave. The time response is then extended to zero value by Prony`s method. The measured and computed data is compared for a parallelepiped resonator of permittivity 37.84.

  14. Tsunami Arrival Detection with High Frequency (HF Radar

    Directory of Open Access Journals (Sweden)

    Donald Barrick

    2012-05-01

    Full Text Available Quantitative real-time observations of a tsunami have been limited to deep-water, pressure-sensor observations of changes in the sea surface elevation and observations of sea level fluctuations at the coast, which are essentially point measurements. Constrained by these data, models have been used for predictions and warning of the arrival of a tsunami, but to date no system exists for local detection of an actual incoming wave with a significant warning capability. Networks of coastal high frequency (HF-radars are now routinely observing surface currents in many countries. We report here on an empirical method for the detection of the initial arrival of a tsunami, and demonstrate its use with results from data measured by fourteen HF radar sites in Japan and USA following the magnitude 9.0 earthquake off Sendai, Japan, on 11 March 2011. The distance offshore at which the tsunami can be detected, and hence the warning time provided, depends on the bathymetry: the wider the shallow continental shelf, the greater this time. We compare arrival times at the radars with those measured by neighboring tide gauges. Arrival times measured by the radars preceded those at neighboring tide gauges by an average of 19 min (Japan and 15 min (USA The initial water-height increase due to the tsunami as measured by the tide gauges was moderate, ranging from 0.3 to 2 m. Thus it appears possible to detect even moderate tsunamis using this method. Larger tsunamis could obviously be detected further from the coast. We find that tsunami arrival within the radar coverage area can be announced 8 min (i.e., twice the radar spectral time resolution after its first appearance. This can provide advance warning of the tsunami approach to the coastline locations.

  15. Unusual Solar Decameter Radio Bursts with High Frequency Cut off

    Science.gov (United States)

    Brazhenko, A. I.; Melnik, V. M.; Frantsuzenko, A. V.; Rucker, H. O.; Panchenko, M.

    2015-03-01

    Solar bursts with high frequency cut off were observed by the URAN-2 radio telescope (Poltava, Ukraine) on 18 August, 2012 in the frequency range 8-32 MHz. Durations of these bursts changed from 30 to 70 s. It is much longer than that for standard type III bursts. Drift rates are much smaller than those of type III bursts are, though much larger than those for decameter type II bursts. In some cases, the drift rate sign changes from the negative to positive one. Some of these bursts have fine structures. Stripes of the fine structures have small drift rates of 20-40 kHz/s. Polarizations of these bursts made about 10 % that apparently indicates that they are generated at the second harmonic of the local plasma frequency. The connection of bursts with the high frequency cut off with compact ejections from the behind-limb active regions is confirmed.

  16. Extended high frequency audiometry in polycystic ovary syndrome.

    Science.gov (United States)

    Kucur, Cuneyt; Kucur, Suna Kabil; Gozukara, Ilay; Seven, Ali; Yuksel, Kadriye Beril; Keskin, Nadi; Oghan, Fatih

    2013-01-01

    Polycystic ovarian syndrome (PCOS) is the most common endocrine disorder affecting 5-10% of women in reproductive age. Insulin resistance, dyslipidemia, glucose intolerance, hypertension, and obesity are metabolic disorders accompanying the syndrome. PCOS is a chronic proinflammatory state and the disease is associated with endothelial dysfunction. In diseases with endothelial damage, hearing in high frequencies are mostly effected in early stages. We evaluated extended high frequency hearing loss in PCOS patients. Forty women diagnosed as PCOS and 25 healthy controls were included in this study. Age and BMI of PCOS and control groups were comparable. Each subject was tested with low (250-2000 Hz), high (4000-8000 Hz), and extended high frequency audiometry (8000-20000). Hormonal and biochemical values including LH, LH/FSH, testosterone, fasting glucose, fasting insulin, HOMA-I, and CRP were calculated. PCOS patients showed high levels of LH, LH/FSH, testosterone, fasting insulin, glucose, HOMA-I, and CRP levels. The hearing thresholds of the groups were similar at frequencies of 250, 500, 1000, 2000, and 4000 Hz; statistically significant difference was observed in 8000-14000 Hz in PCOS group compared to control group. PCOS patients have hearing impairment especially in extended high frequencies. Further studies are needed to help elucidate the mechanism behind hearing impairment in association with PCOS.

  17. Integrated Very High Frequency Switch Mode Power Supplies: Design Considerations

    DEFF Research Database (Denmark)

    Hertel, Jens Christian; Nour, Yasser; Knott, Arnold

    2017-01-01

    This paper presents a power supply using an increased switching frequency to minimize the size of energy storing components, thereby addressing the demands for increased power densities in power supplies. 100 MHz and higher switching frequencies have been used in resonant power converters, which...... simulations. The required spiral inductors was modeled, and simulations show Q values of as high as 14 at a switching frequency of 250 MHz. Simulations of the converter show an efficiency of 55 % with a self oscillating gate drive. However the modeled inductor was not adequate for operating with the self...

  18. Development of Low-Frequency AC Voltage Measurement System Using Single-Junction Thermal Converter

    Science.gov (United States)

    Amagai, Yasutaka; Nakamura, Yasuhiro

    Accurate measurement of low-frequency AC voltage using a digital multimeter at frequencies of 4-200Hz is a challenge in the mechanical engineering industry. At the National Metrology Institute of Japan, we developed a low-frequency AC voltage measurement system for calibrating digital multimeters operating at frequencies down to 1 Hz. The system uses a single-junction thermal converter and employs a theoretical model and a three-parameter sine wave fitting algorithm based on the least-square (LS) method. We calibrated the AC voltage down to 1Hz using our measurement system and reduced the measurement time compared with that using thin-film thermal converters. Our measurement results are verified by comparison with those of a digital sampling method using a high-resolution analog-to-digital converter; our data are in agreement to within a few parts in 105. Our proposed method enables us to measure AC voltage with an uncertainty of 25 μV/V (k = 1) at frequencies down to 4 Hz and a voltage of 10 V.

  19. Extended High Frequency Audiometry in Polycystic Ovary Syndrome

    Directory of Open Access Journals (Sweden)

    Cuneyt Kucur

    2013-01-01

    and BMI of PCOS and control groups were comparable. Each subject was tested with low (250–2000 Hz, high (4000–8000 Hz, and extended high frequency audiometry (8000–20000. Hormonal and biochemical values including LH, LH/FSH, testosterone, fasting glucose, fasting insulin, HOMA-I, and CRP were calculated. Results. PCOS patients showed high levels of LH, LH/FSH, testosterone, fasting insulin, glucose, HOMA-I, and CRP levels. The hearing thresholds of the groups were similar at frequencies of 250, 500, 1000, 2000, and 4000 Hz; statistically significant difference was observed in 8000–14000 Hz in PCOS group compared to control group. Conclusion. PCOS patients have hearing impairment especially in extended high frequencies. Further studies are needed to help elucidate the mechanism behind hearing impairment in association with PCOS.

  20. A Compact High Frequency Doppler Radio Scatterometer for Coastal Oceanography

    Science.gov (United States)

    Flament, P. J.; Harris, D.; Flament, M.; Fernandez, I. Q.; Hlivak, R.; Flores-vidal, X.; Marié, L.

    2016-12-01

    A low-power High Frequency Doppler Radar has been designed for large series production. The use of commercial-off-the-shelf components is maximized to minimize overall cost. Power consumption is reduced to 130W in full duty and 20W in stand-by under 20-36 V-DC, thus enabling solar/wind and/or fuel cell operation by default. For 8 channels, commercial components and sub-assemblies cost less than k20 excluding coaxial antenna cables, and less than four man-weeks of technician suffice for integration, testing and calibration, suggesting a final cost of about k36, based on production batches of 25 units. The instrument is integrated into passively-cooled 90x60x20 cm3 field-deployable enclosures, combining signal generation, transmitter, received, A/D converter and computer, alleviating the need for additional protection such as a container or building. It uses frequency-ramped continuous wave signals, and phased-array transmissions to decouple the direct path to the receivers. Five sub-assemblies are controlled by a Linux embedded computer: (i) direct digital synthesis of transmit and orthogonal local oscillator signals, derived from a low phase noise oven-controlled crystal; (ii) distributed power amplifiers totaling 5 W, integrated into λ/8 passive transmit antenna monopoles; (iii) λ/12 compact active receive antenna monopoles with embedded out-of-band rejection filters; (iv) analog receivers based on complex demodulation by double-balanced mixers, translating the HF spectrum to the audio band; (v) 24-bit analog-to-digital sigma-delta conversion at 12 kHz with 512x oversampling, followed by decimation to a final sampling frequency of 750 Hz. Except for the HF interference rejection filters, the electronics can operate between 3 and 50 MHz with no modification. At 13.5 MHz, 5 W transmit power, 15 min integration time, the high signal-to-noise ratio permits a typical range of 120 km for currents measurements with 8-antenna beam-forming. The University of Hawaii HFR

  1. Carbon nanotube transistor based high-frequency electronics

    Science.gov (United States)

    Schroter, Michael

    At the nanoscale carbon nanotubes (CNTs) have higher carrier mobility and carrier velocity than most incumbent semiconductors. Thus CNT based field-effect transistors (FETs) are being considered as strong candidates for replacing existing MOSFETs in digital applications. In addition, the predicted high intrinsic transit frequency and the more recent finding of ways to achieve highly linear transfer characteristics have inspired investigations on analog high-frequency (HF) applications. High linearity is extremely valuable for an energy efficient usage of the frequency spectrum, particularly in mobile communications. Compared to digital applications, the much more relaxed constraints for CNT placement and lithography combined with already achieved operating frequencies of at least 10 GHz for fabricated devices make an early entry in the low GHz HF market more feasible than in large-scale digital circuits. Such a market entry would be extremely beneficial for funding the development of production CNTFET based process technology. This talk will provide an overview on the present status and feasibility of HF CNTFET technology will be given from an engineering point of view, including device modeling, experimental results, and existing roadblocks. Carbon nanotube transistor based high-frequency electronics.

  2. High frequency in vitro shoot regeneration of Momordica balsamina ...

    African Journals Online (AJOL)

    A protocol was developed for in vitro propagation by multiple shoot induction of Momordica balsamina (Cucurbitaceae), a climber with high medicinal and nutritional values. High frequencies of multiple shoot regeneration were achieved from auxillary bud of nodal explants. The bud explants were cultured on MS media ...

  3. Occupational exposure to anaesthetic gases and high-frequency audiometry.

    Science.gov (United States)

    Giorgianni, Concetto; Gangemi, Silvia; Tanzariello, Maria Giuseppina; Barresi, Gaetano; Miceli, Ludovica; D'Arrigo, Graziella; Spatari, Giovanna

    2015-09-01

    Occupational exposure to anaestethic gases has been suggested to induce auditory damages. The aim of this study is to investigate high-frequency audiometric responses in subjects exposed to anaesthetic gases, in order to highlight the possible effects on auditory system. The study was performed on a sample of 30 medical specialists of Messina University Anaesthesia and Intensive care. We have used tonal audiometry as well as high-frequency one. We have compared the responses with those obtained in a similar control group not exposed to anaesthetic gases. Results were compared statistically. Results show a strong correlation (p = 0.000) between left and right ear responses to all the audiometric tests. The exposed and the control group run though the standard audiometry analysis plays different audiometric responses up only to higher frequencies (2000 HZ p = 0.009 and 4000 Hz p = 0.04); in high-frequency audiometry, as all other frequencies, the attention is drew to the fact that the sample groups distinguish themselves in a significantly statistic way (10,000 Hz p = 0.025, 12,000 Hz p = 0.008, 14,000 Hz p = 0.026, 16,000 Hz p = 0.08). The highest values are the ones related to exposed subjects both in standard (2000 Hz p = 0.01, 4000 Hz p = 0.02) and in high-frequency audiometry (10,000 Hz p = 0.011, 12,000 Hz p = 0.004, 14,000 Hz p = 0.012, 16,000 Hz p = 0.004). Results, even if preliminary and referred to a low-range sample, show an involvement of the anatomic structure responsible for the perception of high-frequency audiometric responses in subjects exposed to anaesthetic gases. © The Author(s) 2012.

  4. Comparison of time and frequency domain measures of RSA in ambulatory recordings.

    NARCIS (Netherlands)

    Goedhart, A.D.; van der Sluis, S.; Houtveen, J.H.; Willemsen, A.H.M.; de Geus, E.J.C.

    2007-01-01

    The extent to which various measures of ambulatory respiratory sinus arrhythmia (RSA) capture the same information across conditions in different subjects remains unclear. In this study the root mean square of successive differences (RMSSD), peak valley RSA (pvRSA), and high frequency power (HF

  5. Monitoring Reading Growth: Goal Setting, Measurement Frequency, and Methods of Evaluation

    Science.gov (United States)

    Jenkins, Joseph; Terjeson, Kari J.

    2011-01-01

    This study examined effects of goal setting, frequency of progress monitoring, and method of evaluating progress on the number of instructional change prompts generated by reading-curriculum-based measurements (CBM). Participants were 31 high-incidence special education students in grades 2-6 selected from 8 schools. Following baseline…

  6. Measurement and control from frequency to phase based on virtual signal reconstruction

    Science.gov (United States)

    Li, Zhiqi; Zhou, Wei; Chen, Jingbiao; Bai, Lina; Chen, Faxi; Xu, Longfei; Ge, Xiaoxia; Miao, Miao

    2018-01-01

    A virtual reconstruction method of directly capturing phase information between different nominal frequency signals, without frequency transformation, is proposed in this paper, building a virtual standard frequency signal whose frequency equals the measured nominal frequency and then making continuous comparison in the measuring gate which is synchronous with multiple periods between the measured signal and the reference frequency signal. Phase variations of the measured signal in every continuous gate are determined, and continuous phase-measuring is implemented. The experimental result verifies this special method for directly processing the phase difference between different nominal frequency signals and realizes a comparison precision of 10-17/day in a wide range.

  7. Fantoni’s Tracheostomy using Catheter High Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    P. Török

    2012-01-01

    Full Text Available Background: It has been shown previously that conventional ventilation delivered through a long cuffed endotracheal tube is associated with a high flow-resistance and frequent perioperative complications. Aim: We attempted to supersede the conventional ventilation by high-frequency jet ventilation through a catheter (HFJV-C and assess safety of the procedure. Material and methods: Using a translaryngeal tracheostomy kit, we performed a translaryngeal (Fantoni tracheostomy (TLT. Subsequently, we introduced a special 2-way prototype ventilatory catheter into the trachea via the TLT under bronchoscopic control. Satisfactory HFJV-C ventilation through the catheter was achieved in 218 patients. Results: There were no significant adverse effects on vital signs observed in the cohort during the study. The pH, SpO2, PaO2, and PaCO2 did not change significantly following the HFJV-C. The intrinsic PEEPi measured in trachea did not exceed 4—5 cm H2O during its application, which was significantly less than during the classical ventilation via the endotracheal tube fluctuating between 12 and 17 cm H2O. No serious medical complications occurred. Conclusion: The HFJV during Fantoni’s tracheostomy using the catheter HFJV-C proved to be a safe and effective method of lung ventilation at the intensive care unit. Key words: Translaryngeal tracheostomy, HFJV via catheter.

  8. High Frequency Mechanical Pyroshock Simulations for Payload Systems

    Energy Technology Data Exchange (ETDEWEB)

    BATEMAN,VESTA I.; BROWN,FREDERICK A.; CAP,JEROME S.; NUSSER,MICHAEL A.

    1999-12-15

    Sandia National Laboratories (SNL) designs mechanical systems with components that must survive high frequency shock environments including pyrotechnic shock. These environments have not been simulated very well in the past at the payload system level because of weight limitations of traditional pyroshock mechanical simulations using resonant beams and plates. A new concept utilizing tuned resonators attached to the payload system and driven with the impact of an airgun projectile allow these simulations to be performed in the laboratory with high precision and repeatability without the use of explosives. A tuned resonator has been designed and constructed for a particular payload system. Comparison of laboratory responses with measurements made at the component locations during actual pyrotechnic events show excellent agreement for a bandwidth of DC to 4 kHz. The bases of comparison are shock spectra. This simple concept applies the mechanical pyroshock simulation simultaneously to all components with the correct boundary conditions in the payload system and is a considerable improvement over previous experimental techniques and simulations.

  9. High brightness, high SNR radio-frequency signal generated by an all-fibered linear-polarization single-mode dual-frequency fiber laser.

    Science.gov (United States)

    Zhao, Xiang; Shen, Hui; Bai, Gang; Zhang, Jingpu; Chen, Xiaolong; Yang, Yifeng; Qi, Yunfeng; He, Bing; Zhou, Jun

    2017-10-30

    A high brightness, high signal-to-noise ratio (SNR) linear-polarization optically generated radio-frequency signal is demonstrated based on an all-fibered master oscillator power amplifier (MOPA) configuration. The seed signal is generated by beating two different frequency beams which are split from the same single frequency laser source. One beam has initial frequency and the other beam is shifted by 200 MHz using an acoustic-optical modulator. The combined beam contains two frequency components with a frequency difference of 200 MHz and this dual-frequency laser signal is then amplified by a three-stage all-fibered amplifier. In order to obtain high brightness output, a single mode fiber with 10 μm core diameter is adopted in the amplifier chain. A designed step-distribution strain is applied on the active fiber for the suppression of stimulated Brillouin scattering (SBS) effect. As a result, up to 143 W output power is achieved with the slop efficiency of 81.4%. The beam quality factors (M 2 ) are measured to 1.06 (Mx2) and 1.04 (My2) and the SNR is up to 54.7 dB. These two frequency components with a certain frequency gap can be identically amplified via the fiber amplifier and the beat note stability, modulation depth as well as SNR are well maintained before and after amplification. To the best of our knowledge, this is the highest reported brightness of the optically generated radio-frequency signal.

  10. Ultra-wide frequency response measurement of an optical system with a DC photo-detector

    KAUST Repository

    Kuntz, Katanya B.

    2017-01-09

    Precise knowledge of an optical device\\'s frequency response is crucial for it to be useful in most applications. Traditional methods for determining the frequency response of an optical system (e.g. optical cavity or waveguide modulator) usually rely on calibrated broadband photo-detectors or complicated RF mixdown operations. As the bandwidths of these devices continue to increase, there is a growing need for a characterization method that does not have bandwidth limitations, or require a previously calibrated device. We demonstrate a new calibration technique on an optical system (consisting of an optical cavity and a high-speed waveguide modulator) that is free from limitations imposed by detector bandwidth, and does not require a calibrated photo-detector or modulator. We use a low-frequency (DC) photo-detector to monitor the cavity\\'s optical response as a function of modulation frequency, which is also used to determine the modulator\\'s frequency response. Knowledge of the frequency-dependent modulation depth allows us to more precisely determine the cavity\\'s characteristics (free spectral range and linewidth). The precision and repeatability of our technique is demonstrated by measuring the different resonant frequencies of orthogonal polarization cavity modes caused by the presence of a non-linear crystal. Once the modulator has been characterized using this simple method, the frequency response of any passive optical element can be determined to a fine resolution (e.g. kilohertz) over several gigahertz.

  11. Correction of Single Frequency Altimeter Measurements for Ionosphere Delay

    Science.gov (United States)

    Schreiner, William S.; Markin, Robert E.; Born, George H.

    1997-01-01

    This study is a preliminary analysis of the accuracy of various ionosphere models to correct single frequency altimeter height measurements for Ionospheric path delay. In particular, research focused on adjusting empirical and parameterized ionosphere models in the parameterized real-time ionospheric specification model (PRISM) 1.2 using total electron content (TEC) data from the global positioning system (GPS). The types of GPS data used to adjust PRISM included GPS line-of-sight (LOS) TEC data mapped to the vertical, and a grid of GPS derived TEC data in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by IRI-90, a climatotogical model, were compared to TOPEX/Poseidon (T/P) TEC measurements from the dual-frequency altimeter for a number of T/P tracks. When adjusted with GPS LOS data, the PRISM empirical model predicted TEC over 24 1 h data sets for a given local time to with in a global error of 8.60 TECU rms during a midnight centered ionosphere and 9.74 TECU rms during a noon centered ionosphere. Using GPS derived sun-fixed TEC data, the PRISM parameterized model predicted TEC within an error of 8.47 TECU rms centered at midnight and 12.83 TECU rms centered at noon. From these best results, it is clear that the proposed requirement of 3-4 TECU global rms for TOPEX/Poseidon Follow-On will be very difficult to meet, even with a substantial increase in the number of GPS ground stations, with any realizable combination of the aforementioned models or data assimilation schemes.

  12. Music students: conventional hearing thresholds and at high frequencies

    Directory of Open Access Journals (Sweden)

    Débora Lüders

    2014-07-01

    Full Text Available INTRODUCTION: Research has shown that hearing loss in musicians may cause difficulty in timbre recognition and tuning of instruments. AIM: To analyze the hearing thresholds from 250 Hz to 16,000 Hz in a group of music students and compare them to a non-musician group in order to determine whether high-frequency audiometry is a useful tool in the early detection of hearing impairment. METHODS: Study design was a retrospective observational cohort. Conventional and high-frequency audiometry was performed in 42 music students (Madsen Itera II audiometer and TDH39P headphones for conventional audiometry, and HDA 200 headphones for high-frequency audiometry. RESULTS: Of the 42 students, 38.1% were female students and 61.9% were male students, with a mean age of 26 years. At conventional audiometry, 92.85% had hearing thresholds within normal limits; but even within the normal limits, the worst results were observed in the left ear for all frequencies, except for 4000 Hz; compared to the non-musician group, the worst results occurred at 500 Hz in the left ear, and at 250 Hz, 6000 Hz, 9000 Hz, 10,000 Hz, and 11,200 Hz in both the ears. CONCLUSION: The periodic evaluation of high-frequency thresholds may be useful in the early detection of hearing loss in musicians.

  13. Music students: conventional hearing thresholds and at high frequencies.

    Science.gov (United States)

    Lüders, Débora; Gonçalves, Cláudia Giglio de Oliveira; Lacerda, Adriana Bender de Moreira; Ribas, Ângela; Conto, Juliana de

    2014-01-01

    Research has shown that hearing loss in musicians may cause difficulty in timbre recognition and tuning of instruments. To analyze the hearing thresholds from 250 Hz to 16,000 Hz in a group of music students and compare them to a non-musician group in order to determine whether high-frequency audiometry is a useful tool in the early detection of hearing impairment. Study design was a retrospective observational cohort. Conventional and high-frequency audiometry was performed in 42 music students (Madsen Itera II audiometer and TDH39P headphones for conventional audiometry, and HDA 200 headphones for high-frequency audiometry). Of the 42 students, 38.1% were female students and 61.9% were male students, with a mean age of 26 years. At conventional audiometry, 92.85% had hearing thresholds within normal limits; but even within the normal limits, the worst results were observed in the left ear for all frequencies, except for 4000 Hz; compared to the non-musician group, the worst results occurred at 500 Hz in the left ear, and at 250 Hz, 6000 Hz, 9000 Hz, 10,000 Hz, and 11,200 Hz in both the ears. The periodic evaluation of high-frequency thresholds may be useful in the early detection of hearing loss in musicians. Copyright © 2014 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  14. High speed high dynamic range high accuracy measurement system

    Science.gov (United States)

    Deibele, Craig E.; Curry, Douglas E.; Dickson, Richard W.; Xie, Zaipeng

    2016-11-29

    A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

  15. Optimized tissue heating by adopting high frequency electrotherapy

    Directory of Open Access Journals (Sweden)

    Jae-cheol Lee

    2015-11-01

    Full Text Available We have developed an electronics circuit that generates a high voltage with a frequency of 0.3–2 MHz to build an electro therapy system that can optimize tissue heating characteristics. These characteristics are used in medical applications. This paper is focused on the analysis of high frequency electro-therapy system to optimize tissue heating with the help of a high voltage pulse signal, which peak voltage is almost 2 kV. This optimized tissue heating between the inner tissue and the thermal distributions has examined in terms of frequency and voltage. The target tissue heating is composed of a single electrode in an experiment that has especially conducted to find the tissue heating characteristics. In the end, a new method for electro-therapy is developed, which is applicable to a specific tissue depth.

  16. [The treatment of glottic carcinoma with high-frequency electrotome].

    Science.gov (United States)

    Mao, Huadong; Xie, Hongwu; Wang, Yakang; Liang, Suqing

    2014-02-01

    To investigate the surgery management of glottic carcinoma with high-frequency electrotome. Twenty cases of patients with glottic carcinoma were treated by cordectomy under micro-laryngoscopy with high-frequency electrotome. The 20 patients were followed up from 5 months to 6 years, retained good laryngeal function and structure: 1 case had local recurrences after 6 months, underwent total laryngectomy, and now no recurrence had been found: 19 cases (mild adhesions of vocal cords formed in 2 cases) had no local recurrence nor lymph node metastasis. It is unnecessary to invest in expensive equipment in the cordectomy under micro-laryngoscopy with high frequency electrotome under general anesthesia and the result is satisfactory.

  17. High-frequency TRNS reduces BOLD activity during visuomotor learning.

    Directory of Open Access Journals (Sweden)

    Catarina Saiote

    Full Text Available Transcranial direct current stimulation (tDCS and transcranial random noise stimulation (tRNS consist in the application of electrical current of small intensity through the scalp, able to modulate perceptual and motor learning, probably by changing brain excitability. We investigated the effects of these transcranial electrical stimulation techniques in the early and later stages of visuomotor learning, as well as associated brain activity changes using functional magnetic resonance imaging (fMRI. We applied anodal and cathodal tDCS, low-frequency and high-frequency tRNS (lf-tRNS, 0.1-100 Hz; hf-tRNS 101-640 Hz, respectively and sham stimulation over the primary motor cortex (M1 during the first 10 minutes of a visuomotor learning paradigm and measured performance changes for 20 minutes after stimulation ceased. Functional imaging scans were acquired throughout the whole experiment. Cathodal tDCS and hf-tRNS showed a tendency to improve and lf-tRNS to hinder early learning during stimulation, an effect that remained for 20 minutes after cessation of stimulation in the late learning phase. Motor learning-related activity decreased in several regions as reported previously, however, there was no significant modulation of brain activity by tDCS. In opposition to this, hf-tRNS was associated with reduced motor task-related-activity bilaterally in the frontal cortex and precuneous, probably due to interaction with ongoing neuronal oscillations. This result highlights the potential of lf-tRNS and hf-tRNS to differentially modulate visuomotor learning and advances our knowledge on neuroplasticity induction approaches combined with functional imaging methods.

  18. High frequency conductivity of hot electrons in carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Amekpewu, M., E-mail: mamek219@gmail.com [Department of Applied Physics, University for Development Studies, Navrongo (Ghana); Mensah, S.Y. [Department of Physics, College of Agriculture and Natural Sciences, U.C.C. (Ghana); Musah, R. [Department of Applied Physics, University for Development Studies, Navrongo (Ghana); Mensah, N.G. [Department of Mathematics, College of Agriculture and Natural Sciences, U.C.C. (Ghana); Abukari, S.S.; Dompreh, K.A. [Department of Physics, College of Agriculture and Natural Sciences, U.C.C. (Ghana)

    2016-05-01

    High frequency conductivity of hot electrons in undoped single walled achiral Carbon Nanotubes (CNTs) under the influence of ac–dc driven fields was considered. We investigated semi-classically Boltzmann's transport equation with and without the presence of the hot electrons’ source by deriving the current densities in CNTs. Plots of the normalized current density versus frequency of ac-field revealed an increase in both the minimum and maximum peaks of normalized current density at lower frequencies as a result of a strong injection of hot electrons. The applied ac-field plays a twofold role of suppressing the space-charge instability in CNTs and simultaneously pumping an energy for lower frequency generation and amplification of THz radiations. These have enormous promising applications in very different areas of science and technology.

  19. Lead extraction experience with high frequency excimer laser.

    Science.gov (United States)

    Tanawuttiwat, Tanyanan; Gallego, Daniel; Carrillo, Roger G

    2014-09-01

    A higher frequency Excimer laser sheath using an 80-Hz pulse repetitive rate was approved by the Food and Drug Administration in April 2012. We reported our initial clinical experience with a high-frequency Excimer laser sheath and compared it with lower-frequency laser sheaths which have been previously used. In this single center, retrospective cohort study, we evaluated patients who underwent lead extraction from December 2008 to May 2013. Those who underwent lead removal without using a laser sheath or with approaches other than subclavian were excluded. Primary endpoints included total laser time, number of pulses, and complications. Data on clinical characteristics, lead type, indications, and outcomes were prospectively collected and analyzed. A total of 427 patients were included in the study (72.6% male; age 67.9 ± 15.23 years). Lower frequency and higher frequency laser sheaths were used in 315 and 112 patients, respectively. A total of 821 leads were removed with 765 leads (93.2%) extracted using the Excimer laser sheath. Lead age was 5.71 ± 4.96 years. Complete extraction was seen in all patients. A higher-frequency laser sheath was associated with a lower laser time and a lower total number of laser pulses even after adjustments for the number of leads, type of leads, and lead age. In the higher frequency group, mortality rate was 0.9% and minor complication rate was 3.6%. When compared with the lower-frequency laser sheath, the higher-frequency laser sheath requires less laser times and more efficient amount of pulses for lead extraction with comparable success rate. Due to the rarity of major and minor complications, no statistical significance was found between the two groups. ©2014 Wiley Periodicals, Inc.

  20. Early deactivation of slower muscle fibres at high movement frequencies.

    Science.gov (United States)

    Blake, Ollie M; Wakeling, James M

    2014-10-01

    Animals produce rapid movements using fast cyclical muscle contractions. These types of movements are better suited to faster muscle fibres within muscles of mixed fibre types as they can shorten at faster velocities and achieve higher activation-deactivation rates than their slower counterparts. Preferential recruitment of faster muscle fibres has previously been shown during high velocity contractions. Additionally, muscle deactivation takes longer than activation and therefore may pose a limitation to fast cyclical contractions. It has been speculated that slower fibres may be deactivated before faster fibres to accommodate their longer deactivation time. This study aimed to test whether shifts in muscle fibre recruitment occur with derecruitment of slow fibres before faster fibres at high cycle frequencies. Electromyographic (EMG) signals were collected from the medial gastrocnemius at an extreme range of cycle frequencies and workloads. Wavelets were used to resolve the EMG signals into time and frequency space and the primary sources of variability within the EMG frequency spectra were identified through principal component analysis. Early derecruitment of slower fibres was evident at the end of muscle excitation at higher cycle frequencies, as determined by reduced low-frequency EMG content, and additional slower fibre recruitment was present at the highest cycle frequency. The duration of muscle excitation reached a minimum of about 150 ms and did not change for the three highest cycle frequencies, suggesting a duration limit for the medial gastrocnemius. This study provides further evidence of modifications of muscle fibre recruitment strategies to meet the mechanical demands of movement. © 2014. Published by The Company of Biologists Ltd.

  1. High-frequency, three-phase current controller implementation in an FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M.; Round, S. D.; Kolar, J. W.

    2008-07-01

    Three phase rectifiers with switching frequencies of 500 kHz or more require high speed current controllers. At such high switching frequencies analog controllers as well as high speed digital signal processing (DSP) systems have limited performance. In this paper, two high speed current controller implementations using two different field-programmable gate arrays (FPGA) - one for switching frequencies up to 1 MHz and one for switching frequencies beyond 1 MHz - are presented to overcome this performance limitation. Starting with the digital system design all the blocks of the signal chain, containing analog-to-digital (A/D) interface, digital controller implementation using HW-multipliers and implementation of a novel high speed, high resolution pulse width modulation (PWM) are discussed and compared. Final measurements verify the performance of the controllers. (author)

  2. Extracting cardiac myofiber orientations from high frequency ultrasound images

    Science.gov (United States)

    Qin, Xulei; Cong, Zhibin; Jiang, Rong; Shen, Ming; Wagner, Mary B.; Kirshbom, Paul; Fei, Baowei

    2013-03-01

    Cardiac myofiber plays an important role in stress mechanism during heart beating periods. The orientation of myofibers decides the effects of the stress distribution and the whole heart deformation. It is important to image and quantitatively extract these orientations for understanding the cardiac physiological and pathological mechanism and for diagnosis of chronic diseases. Ultrasound has been wildly used in cardiac diagnosis because of its ability of performing dynamic and noninvasive imaging and because of its low cost. An extraction method is proposed to automatically detect the cardiac myofiber orientations from high frequency ultrasound images. First, heart walls containing myofibers are imaged by B-mode high frequency (pig hearts.

  3. The Impact of Very High Frequency Surface Reverberation on Coherent Acoustic Propagation and Modeling

    Science.gov (United States)

    2015-09-30

    The third primary objective is to characterize high frequency wave noise in environmental simulators , the surf zone and the open ocean. 2 In...conducted in a wind-wave simulator at Scripps Institution of Oceanography, and will transition next year to the littoral zone off La Jolla Shores Beach...and work in this initial phase has focused on laboratory measurements of high frequency surface scattering, simulations of the scattered signal and

  4. Thrombolysis using multi-frequency high intensity focused ultrasound at MHz range: an in vitro study.

    Science.gov (United States)

    Suo, Dingjie; Guo, Sijia; Lin, Weili; Jiang, Xiaoning; Jing, Yun

    2015-09-21

    High intensity focused ultrasound (HIFU) based thrombolysis has emerged as a promising drug-free treatment approach for ischemic stroke. The large amount of acoustic power required by this approach, however, poses a critical challenge to the future clinical translation. In this study, multi-frequency acoustic waves at MHz range (near 1.5 MHz) were introduced as HIFU excitations to reduce the required power for treatment as well as the treatment time. In vitro bovine blood clots weighing around 150 mg were treated by single-frequency and multi-frequency HIFU. The pulse length was 2 ms for all experiments except the ones where the duty cycle was changed. It was found that dual-frequency thrombolysis efficiency was statistically better than single-frequency under the same acoustic power and excitation condition. When varying the acoustic power but fixing the duty cycle at 5%, it was found that dual-frequency ultrasound can save almost 30% power in order to achieve the same thrombolysis efficiency. In the experiment where the duty cycle was increased from 0.5% to 10%, it was shown that dual-frequency ultrasound can achieve the same thrombolysis efficiency with only half of the duty cycle of single-frequency. Dual-frequency ultrasound could also accelerate the thrombolysis by a factor of 2-4 as demonstrated in this study. No significant differences were found between dual-frequencies with different frequency differences (0.025, 0.05, and 0.1 MHz) and between dual-frequency and triple-frequency. The measured cavitation doses of dual-frequency and triple-frequency excitations were at about the same level but both were significantly higher than that of single-frequency.

  5. Sustainable limitation of high-frequency oscillations of elevator cabin

    Science.gov (United States)

    Kaytukov, Batraz

    2017-10-01

    In this paper, a problem of sustainable limitation of vertical high-frequency oscillations of elevator cabin in buildings with various number of storeys is considered. To solve this problem, dynamic model of the elevator movement was developed. In the course of analytical and experimental studies, the main cause for emergence of undesirable high-frequency oscillations of a cabin was defined. The amplification factor which is the function of λ and length of cable was determined. The λ parameter is variable, and length of the cable changes depending on length passed by the cabin and is an amplification factor argument. For sustainable limitation of oscillations, use of dynamic dumper of lever type is proposed. Adjustment of the dumper natural vibration frequency in such a way that it is equal to the excitation frequency allows limiting of oscillations of the cabin and the elevator machine to reasonable value irrespective to position of a moving cabin in the shaft. Using dependences and plots which were obtained in the course of scientific analysis and experimental studies, reasonability of dumper application for sustainable limitation of high-frequency influence of the elevator machine on the base and obtaining of solutions of inertial forces equilibration problem was proved.

  6. Carbon fiber and void detection using high-frequency electromagnetic induction techniques

    Science.gov (United States)

    Barrowes, Benjamin E.; Sigman, John B.; Wang, YinLin; O'Neill, Kevin A.; Shubitidze, Fridon; Simms, Janet; Bennett, Hollis J.; Yule, Donald E.

    2016-05-01

    Ultrawide band electromagnetic induction (EMI) instruments have been traditionally used to detect high electric conductivity discrete targets such as metal unexploded ordnance. The frequencies used for this EMI regime have typically been less than 100 kHz. To detect intermediate conductivity objects like carbon fiber, even less conductive saturated salts, and even voids embedded in conducting soils, higher frequencies up to the low megahertz range are required in order to capture characteristic responses. To predict EMI phenomena at frequencies up to 15 MHz, we first modeled the response of intermediate conductivity targets using a rigorous, first-principles approach, the Method of Auxiliary Sources. A newly fabricated benchtop high-frequency electromagnetic induction instrument produced EMI data at frequencies up to that same high limit. Modeled and measured characteristic relaxation signatures compare favorably and indicate new sensing possibilities in a variety of scenarios.

  7. Computation of High-Frequency Waves with Random Uncertainty

    KAUST Repository

    Malenova, Gabriela

    2016-01-06

    We consider the forward propagation of uncertainty in high-frequency waves, described by the second order wave equation with highly oscillatory initial data. The main sources of uncertainty are the wave speed and/or the initial phase and amplitude, described by a finite number of random variables with known joint probability distribution. We propose a stochastic spectral asymptotic method [1] for computing the statistics of uncertain output quantities of interest (QoIs), which are often linear or nonlinear functionals of the wave solution and its spatial/temporal derivatives. The numerical scheme combines two techniques: a high-frequency method based on Gaussian beams [2, 3], a sparse stochastic collocation method [4]. The fast spectral convergence of the proposed method depends crucially on the presence of high stochastic regularity of the QoI independent of the wave frequency. In general, the high-frequency wave solutions to parametric hyperbolic equations are highly oscillatory and non-smooth in both physical and stochastic spaces. Consequently, the stochastic regularity of the QoI, which is a functional of the wave solution, may in principle below and depend on frequency. In the present work, we provide theoretical arguments and numerical evidence that physically motivated QoIs based on local averages of |uE|2 are smooth, with derivatives in the stochastic space uniformly bounded in E, where uE and E denote the highly oscillatory wave solution and the short wavelength, respectively. This observable related regularity makes the proposed approach more efficient than current asymptotic approaches based on Monte Carlo sampling techniques.

  8. Automated screening for high-frequency hearing loss.

    Science.gov (United States)

    Vlaming, Marcel S M G; MacKinnon, Robert C; Jansen, Marije; Moore, David R

    2014-01-01

    Hearing loss at high frequencies produces perceptual difficulties and is often an early sign of a more general hearing loss. This study reports the development and validation of two new speech-based hearing screening tests in English that focus on detecting hearing loss at frequencies above 2000 Hz. The Internet-delivered, speech-in noise tests used closed target-word sets of digit triplets or consonant-vowel-consonant (CVC) words presented against a speech-shaped noise masker. The digit triplet test uses the digits 0 to 9 (excluding the disyllabic 7), grouped in quasi-random triplets. The CVC test uses simple words (e.g., "cat") selected for the high-frequency spectral content of the consonants. During testing, triplets or CVC words were identified in an adaptive procedure to obtain the speech reception threshold (SRT) in noise. For these new, high-frequency (HF) tests, the noise was low-pass filtered to produce greater masking of the low-frequency speech components, increasing the sensitivity of the test for HF hearing loss. Individual test tokens (digits, CVCs) were first homogenized using a group of 10 normal-hearing (NH) listeners by equalizing intelligibility across tokens at several speech-in-noise levels. Both tests were then validated and standardized using groups of 24 NH listeners and 50 listeners with hearing impairment. Performance on the new high frequency digit triplet (HF-triplet) and CVC (HF-CVC) tests was compared with audiometric hearing loss, and with that on the unfiltered, broadband digit triplet test (BB-triplet) test, and the ASL (Adaptive Sentence Lists) speech-in-noise test. The HF-triplet and HF-CVC test results (SRT) both correlated positively and highly with high-frequency audiometric hearing loss and with the ASL test. SRT for both tests as a function of high-frequency hearing loss increased at nearly three times the rate as that of the BB-triplet test. The intraindividual variability (SD) on the tests was about 2.1 (HF-triplet) and 1

  9. Pigeons use high spatial frequencies when memorizing pictures.

    Science.gov (United States)

    Murphy, Matthew S; Brooks, Daniel I; Cook, Robert G

    2015-07-01

    The ability of animals to visually memorize and categorize a large number of pictures is well established. Determining the kinds of information animals use to accomplish these goals has been more difficult. This experiment examined the contribution of spatial frequency information to picture memorization by pigeons. A series of grayscale pictures were notch-filtered to eliminate different portions of the spatial frequency spectrum of memorized pictures. The results indicated that the higher spatial frequencies in the pictures were most important to accurate recognition, suggesting that the detection of fine detail at the high range of pigeon visual acuity was a critical component to their memorized representations. Subsequent tests with band-pass and hybrid conflict stimuli confirmed this conclusion. It is suggested that cognitive and task demands may determine how spatial frequency is used by pigeons, with higher frequencies more important to item memorization, while lower spatial frequencies may contribute to categorization in other types of discrimination tasks. (c) 2015 APA, all rights reserved).

  10. Ion velocity distribution function and electric field measurements in a dual-frequency rf sheath

    Science.gov (United States)

    Moore, Nathaniel; Gekelman, Walter; Prybil, Patrick; Zhang, Yiting; Kushner, Mark

    2013-10-01

    Ion dynamics are investigated in a dual-frequency rf sheath above a 300 mm diameter biased silicon wafer in an industrial inductively coupled (440 kHz, 500 W) plasma etch tool. Ion velocity distribution (IVD) function measurements in the argon plasma are taken using laser induced fluorescence (LIF). Planar sheets of laser light enter the chamber both parallel and perpendicular to the surface of the wafer in order to measure both parallel and perpendicular IVDs at thousands of spatial positions. A fast (30 ns exposure) CCD camera measures the resulting fluorescence with a spatial resolution of 0.4 mm. The dual-frequency bias on the wafer is comprised of a 2 MHz low frequency bias and an adjustable 10-20 MHz high frequency bias. The bias voltages may be switched on and off (frep up to 1 kHz, duty cycle 10-90%). IVDs are measured with several different bias and timing combinations. For the 2 MHz bias, it was found that the IVD is uniform to within 5% across the wafer. IVDs as a function of phase of the bias were also measured. The electric field in the sheath was measured volumetrically over the wafer at thousands of positions using an emissive probe. The experimental results are compared with a simulation specifically designed for this particular plasma tool. Work supported by the NSF and DOE.

  11. Challenges in graphene integration for high-frequency electronics

    Science.gov (United States)

    Giannazzo, F.; Fisichella, G.; Greco, G.; Roccaforte, F.

    2016-06-01

    This paper provides an overview of the state-of-the-art research on graphene (Gr) for high-frequency (RF) devices. After discussing current limitations of lateral Gr RF transistors, novel vertical devices concepts such as the Gr Base Hot Electron Transistor (GBHET) will be introduced and the main challenges in Gr integration within these architectures will be discussed. In particular, a GBHET device based on Gr/AlGaN/GaN heterostructure will be considered. An approach to the fabrication of this heterostructure by transfer of CVD grown Gr on copper to the AlGaN surface will be presented. The morphological and electrical properties of this system have been investigated at nanoscale by atomic force microscopy (AFM) and conductive atomic force microscopy (CAFM). In particular, local current-voltage measurements by the CAFM probe revealed the formation of a Schottky contact with low barrier height (˜0.41 eV) and excellent lateral uniformity between Gr and AlGaN. Basing on the electrical parameters extracted from this characterization, the theoretical performances of a GBHET formed by a metal/Al2O3/Gr/AlGaN/GaN stack have been evaluated.

  12. Improving NASICON Sinterability through Crystallization under High Frequency Electrical Fields

    Directory of Open Access Journals (Sweden)

    Ilya eLisenker

    2016-03-01

    Full Text Available The effect of high frequency (HF electric fields on the crystallization and sintering rates of a lithium aluminum germanium phosphate (LAGP ion conducting ceramic was investigated. LAGP with the nominal composition Li1.5Al0.5Ge1.5(PO43 was crystallized and sintered, both conventionally and under effect of electrical field. Electrical field application, of 300V/cm at 1MHz, produced up to a 40% improvement in sintering rate of LAGP that was crystallized and sintered under the HF field. Heat sink effect of the electrodes appears to arrest thermal runaway and subsequent flash behavior. Sintered pellets were characterized using XRD, SEM, TEM and EIS to compare conventionally and field sintered processes. The as-sintered structure appears largely unaffected by the field as the sintering curves tend to converge beyond initial stages of sintering. Differences in densities and microstructure after 1 hour of sintering were minor with measured sintering strains of 31% vs. 26% with and without field, respectively . Ionic conductivity of the sintered pellets was evaluated and no deterioration due to the use of HF field was noted, though capacitance of grain boundaries due to secondary phases was significantly increased.

  13. Bottomside Ionospheric Electron Density Specification using Passive High Frequency Signals

    Science.gov (United States)

    Kaeppler, S. R.; Cosgrove, R. B.; Mackay, C.; Varney, R. H.; Kendall, E. A.; Nicolls, M. J.

    2016-12-01

    The vertical bottomside electron density profile is influenced by a variety of natural sources, most especially traveling ionospheric disturbances (TIDs). These disturbances cause plasma to be moved up or down along the local geomagnetic field and can strongly impact the propagation of high frequency radio waves. While the basic physics of these perturbations has been well studied, practical bottomside models are not well developed. We present initial results from an assimilative bottomside ionosphere model. This model uses empirical orthogonal functions based on the International Reference Ionosphere (IRI) to develop a vertical electron density profile, and features a builtin HF ray tracing function. This parameterized model is then perturbed to model electron density perturbations associated with TIDs or ionospheric gradients. Using the ray tracing feature, the model assimilates angle of arrival measurements from passive HF transmitters. We demonstrate the effectiveness of the model using angle of arrival data. Modeling results of bottomside electron density specification are compared against suitable ancillary observations to quantify accuracy of our model.

  14. Features of the high frequency power transformer calculation

    Directory of Open Access Journals (Sweden)

    D.A. Zabarilo

    2013-06-01

    Full Text Available Purpose. The windings of power transformers have low resistance value and a most inductance, which reduces the rate of rise of current in the windings. Therefore, when the estimated amount of current is set one should make sure of the possibility of achieving it. As inductance is characterized by a short-circuit voltage, it is necessary to develop a technique for determining the maximum magnitude of the current in the windings of the transformer according to the short-circuit voltage and operating frequency. Methodology. The classical method of calculation of transient processes to determine the value of the transient current of the transformer windings to achieve purpose is used. Findings. The nature of the transient current in the windings of high-frequency transformer, which is powered by a voltage inverter is investigated and analyzed. Originality. The method for determining the maximum amount of current depending on the short-circuit voltage and frequency of the applied voltage with other set-up parameters was proposed. Practical value. The proposed method allows determining the maximum value of the current in the windings of the high-frequency transformer including its RL-parameters. This will let compare the value of a given current with possible depending on short-circuit voltage and frequency of the applied voltage. Research material may be applied for power transformers design.

  15. Fact or friction: jumps at ultra high frequency

    NARCIS (Netherlands)

    Christensen, K.; Oomen, R.; Podolskij, M.

    2011-01-01

    In this paper, we demonstrate that jumps in financial asset prices are not nearly as common as generally thought, and that they account for only a very small proportion of total return variation. We base our investigation on an extensive set of ultra high-frequency equity and foreign exchange rate

  16. High frequency plant regeneration from shoot tip explants of ...

    African Journals Online (AJOL)

    A high frequency and rapid regeneration protocol was developed from shoot tip explants of Citrullus colocynthis on Murashige and Skoog (MS) medium supplemented with N6-benzylamino-purine (BAP, 0.5 mg/l) and α-naphthalene acetic acid (NAA, 0.5 mg/l). Highest number of shoots (23.0 ± 0.567) was obtained on MS ...

  17. High frequency MOSFET gate drivers technologies and applications

    CERN Document Server

    Zhang, Zhiliang

    2017-01-01

    This book describes high frequency power MOSFET gate driver technologies, including gate drivers for GaN HEMTs, which have great potential in the next generation of switching power converters. Gate drivers serve as a critical role between control and power devices.

  18. Collocations of High Frequency Noun Keywords in Prescribed Science Textbooks

    Science.gov (United States)

    Menon, Sujatha; Mukundan, Jayakaran

    2012-01-01

    This paper analyses the discourse of science through the study of collocational patterns of high frequency noun keywords in science textbooks used by upper secondary students in Malaysia. Research has shown that one of the areas of difficulty in science discourse concerns lexis, especially that of collocations. This paper describes a corpus-based…

  19. Development and Testing of Adaptive HF (High Frequency) Radio Techniques

    Science.gov (United States)

    1984-10-01

    December 1980). 2. HFDM : AN/USQ-83(XH-1)(V), The High Frequency Digital Modem, Opera- tion and Maintenance Manual, Sylvania Systems Group, Needham Heights...the HF digital modem ( HFDM ) 2 that per- mits implementing of different modulaticn formats simply by changing the program code. The sounding signal can

  20. Frequency of Guns in the Households of High School Seniors

    Science.gov (United States)

    Coker, Ann L.; Bush, Heather M.; Follingstad, Diane R.; Brancato, Candace J.

    2017-01-01

    Background: In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. Methods: In this cohort study of 3,006 high school seniors from 24 schools, we examined the frequency of household guns ownership. Results: About 65%…

  1. Modelling financial high frequency data using point processes

    DEFF Research Database (Denmark)

    Hautsch, Nikolaus; Bauwens, Luc

    In this chapter written for a forthcoming Handbook of Financial Time Series to be published by Springer-Verlag, we review the econometric literature on dynamic duration and intensity processes applied to high frequency financial data, which was boosted by the work of Engle and Russell (1997...

  2. High resolution mid-infrared spectroscopy based on frequency upconversion

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Hu, Qi; Tidemand-Lichtenberg, Peter

    2013-01-01

    We present high resolution upconversion of incoherent infrared radiation by means of sum-frequency mixing with a laser followed by simple CCD Si-camera detection. Noise associated with upconversion is, in strong contrast to room temperature direct mid-IR detection, extremely small, thus very faint...

  3. Current barriers to confine high frequency common mode currents

    NARCIS (Netherlands)

    Moonen, Dominicus Johannes Guilielmus; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2016-01-01

    A commercially produced three phase power line filter is submitted to a Current Barrier (CB) Electro-Magnetic Compatibility (EMC) zoning strategy as an attempt to confine high frequency common mode currents. The intent of the paper is not to show how to build a ’perfect’ filter, since this is known.

  4. Practical techniques for enhancing the high-frequency MASW method

    Science.gov (United States)

    For soil exploration in the vadose zone, a high-frequency multi-channel analysis of surface waves (HF-MASW) method has been developed. In the study, several practical techniques were applied to enhance the overtone image of the HF-MASW method. They included (1) the self-adaptive MASW method using a ...

  5. High frequency ultrasound imaging of a single-species biofilm

    NARCIS (Netherlands)

    Shemesh, H.; Goertz, D. E.; van der Sluis, L. W. M.; de Jong, N.; Wu, M. K.; Wesselink, P. R.

    Objective: This study evaluated the feasibility of a high frequency ultrasound scan to examine the 3D morphology of Streptococcus mutans biofilms grown in vitro. Methods: Six 2-day S. mutans biofilms and six 7-day biofilms were grown on tissue culture membranes and on bovine dentine discs. A sterile

  6. Planck 2013 results. VI. High Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143,217, 353, 545...

  7. High-frequency Trading, Algorithmic Finance, and the Flash Crash

    DEFF Research Database (Denmark)

    Borch, Christian

    2016-01-01

    The Flash Crash of 6 May 2010 has an interesting status in discussions of high-frequency trading, i.e. fully automated, superfast computerized trading: it is invoked both as an important illustration of how this field of algorithmic trading operates and, more often, as an example of how fully aut...

  8. High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing

    OpenAIRE

    MacLachlan, Robert A.; Riviere, Cameron N.

    2009-01-01

    Position-sensitive detectors (PSDs), or lateral-effect photodiodes, are commonly used for high-speed, high-resolution optical position measurement. This paper describes the instrument design for multidimensional position and orientation measurement based on the simultaneous position measurement of multiple modulated sources using frequency-domain-multiplexed (FDM) PSDs. The important advantages of this optical configuration in comparison with laser/mirror combinations are that it has a large ...

  9. High-frequency Oscillations in Eyewalls of Tropical Cyclones

    Science.gov (United States)

    Li, Weibiao; Chen, Shumin

    2017-04-01

    High-frequency oscillations, with periods of about 2 hours, are first identified by applying wavelet analysis to observed minutely wind speeds around the eye and eyewall of tropical cyclones (TCs). Analysis of a model simulation of Typhoon Hagupit (2008) shows that the oscillations also occur in the intensity of TC, vertical motion, convergence activity and air density around the eyewall. Sequences of oscillations in these variables follow a certain order. In a typical cycle, the drop of density in the planetary boundary layer (PBL) is followed by an increase in the inward radial wind; this enhanced frictional convergence causes increase in density, followed by a decrease in the inward radial wind. The increase in convergence in the PBL causes increase of updraft at the top of the PBL, followed by high vertical velocity at high altitude of 8-10 km, then the increase of the maximum wind speed, and vice versa. Key words: tropical cyclone, high-frequency oscillations, eyewall, intensity

  10. Very High Frequency Switch-Mode Power Supplies

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre

    The importance of technology and electronics in our daily life is constantly increasing. At the same time portability and energy efficiency are currently some of the hottest topics. This creates a huge need for power converters in a compact form factor and with high efficiency, which can supply...... band gap semiconductors and integrated power supplies. Afterwards a wide range of topologies suited for operation at very high frequencies is investigated and the most promising ones are tested experimentally. Through a comparison of these topologies the class DE inverter is found to be superior...... to the other alternatives, at least for converters with hundreds of volts as input and a few tens of watts output power. A class DE inverter does however require a high side gate drive, which have never been presented before for these frequencies and voltages. This thesis presents the worlds first high side...

  11. Very High Frequency Monitoring System for Engine Gearbox and Generator Health Management (Postprint)

    Science.gov (United States)

    2007-09-18

    measurement of VHF vibration. This instrumentation includes high bandwidth piezoelectric accelerometers and a laser vibrometer , as seen in Table 1. Table...Bandwidth Piezoelectric Accelerometers Most commonly used, variety of sizes and configurations Optical Laser Vibrometer System 500 kHz Bandwidth, dynamic... piezoelectric , optical, and acoustic frequency measurements for improved, incipient anomaly detection. These gas turbine engine vibration monitoring technologies

  12. Automated Screening for High-Frequency Hearing Loss

    OpenAIRE

    Vlaming, Marcel S M G; Mackinnon, Robert C.; Jansen, Marije; Moore, David R.

    2014-01-01

    OBJECTIVE: Hearing loss at high frequencies produces perceptual difficulties and is often an early sign of a more general hearing loss. This study reports the development and validation of two new speech-based hearing screening tests in English that focus on detecting hearing loss at frequencies above 2000 Hz. DESIGN: The Internet-delivered, speech-in noise tests used closed target-word sets of digit triplets or consonant-vowel-consonant (CVC) words presented against a speech-shaped noise mas...

  13. High-power non linear frequency converted laser diodes

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Andersen, Peter E.; Hansen, Anders Kragh

    2015-01-01

    We present different methods of generating light in the blue-green spectral range by nonlinear frequency conversion of tapered diode lasers achieving state-of-the-art power levels. In the blue spectral range, we show results using single-pass second harmonic generation (SHG) as well as cavity...... enhanced sum frequency generation (SFG) with watt-level output powers. SHG and SFG are also demonstrated in the green spectral range as a viable method to generate up to 4 W output power with high efficiency using different configurations....

  14. Planck 2013 results. VI. High Frequency Instrument data processing

    OpenAIRE

    Planck Collaboration; Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.

    2013-01-01

    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857GHz with an angular resolution ranging from 9.́7 to 4.́6. The detector noise per (effective) beam solid angle is respectively, 10, 6 , 12, and 39 μK in the four lowest HFI frequency channels (10...

  15. Occupational hearing loss: tonal audiometry X high frequencies audiometry

    Directory of Open Access Journals (Sweden)

    Lauris, José Roberto Pereira

    2009-09-01

    Full Text Available Introduction: Studies on the occupational exposure show that noise has been reaching a large part of the working population around the world, and NIHL (noise-induced hearing loss is the second most frequent disease of the hearing system. Objective: To review the audiometry results of employees at the campus of the University of São Paulo, Bauru. Method: 40 audiometry results were analyzed between 2007 and 2008, whose ages comprised between 32 and 59 years, of both sexes and several professions: gardeners, maintenance technicians, drivers etc. The participants were divided into 2 groups: those with tonal thresholds within acceptable thresholds and those who presented auditory thresholds alterations, that is tonal thresholds below 25 dB (NA in any frequency (Administrative Rule no. 19 of the Ministry of Labor 1998. In addition to the Conventional Audiologic Evaluation (250Hz to 8.000Hz we also carried out High Frequencies Audiometry (9000Hz, 10000Hz, 11200Hz, 12500Hz, 14000Hz and 16000Hz. Results: According to the classification proposed by FIORINI (1994, 25.0% (N=10 they presented with NIHL suggestive audiometric configurations. The results of high frequencies Audiometry confirmed worse thresholds than those obtained in the conventional audiometry in the 2 groups evaluated. Conclusion: The use of high frequencies audiometry proved to be an important register as a hearing alteration early detection method.

  16. 75 FR 81284 - Nationwide Use of High Frequency and Ultra High Frequency Active SONAR Technology; Draft...

    Science.gov (United States)

    2010-12-27

    ... such as Hurricanes Katrina and Rita of 2005; established security areas around high-value vessels... appropriate location for inspection would be at a water depth that would preclude seafloor disturbance. As... technology during times of extreme weather, such as hurricanes, could be required for onshore areas that...

  17. Tube method of sound-absorption measurement extended to frequencies far above cutoff

    Science.gov (United States)

    Shields, F. D.; Bass, H. E.; Bolen, L. N.

    1977-01-01

    Equipment had been constructed for measuring sound absorption in the frequency range from 4 to 100 kHz in a large tube 25.4 cm in diameter and 4.8-m long. The technique employs a large moveable solid-dielectric capacitance transducer that completely fills the tube cross section and generates pulses of plane waves. An identical transducer terminates the other end of the tube and serves as a microphone to detect and reflect the sound pulses. Measurements in argon, nitrogen, and air indicate that the attenuation of the sound pulses differs by less than 1% from values calculated for the zero-order mode for frequencies up to 44 times the cutoff frequency for the first 'nonplane' mode. Above that frequency, the measured values are less than those predicted by theory by an amount that is approximately proportional to the wavelength to the -3.1 power. In a smaller tube of similar construction, the high-frequency deviation from theory is absent.

  18. Highly flexible distributions to fit multiple frequency financial returns

    Science.gov (United States)

    BenSaïda, Ahmed; Slim, Skander

    2016-01-01

    Financial data are usually studied via low flexible distributions, independently of the frequency of the data, due to their simplicity and analytical tractability. In this paper we analyze two highly flexible five-parameter distributions into fitting financial returns, these are the skewed generalized t (SGT) and the generalized hyperbolic (GH). Applications carried on two exchange rates (Euro-Dollar and Dollar-Yen), and two indexes (S&P 500 and Nikkei 225) over four frequencies: weekly, daily, 30-min and 5-min, confirm the superiority of the SGT and GH in approximating the distribution of a given data at a remarkable precision. Moreover, as we move from higher to lower frequency, the distribution's overall shape does indeed change radically, and the estimated parameters refute the tendency to normality, which calls into question the aggregational Gaussianity's stylized fact.

  19. Graphene Quantum Capacitors for High Frequency Tunable Analog Applications.

    Science.gov (United States)

    Moldovan, Clara F; Vitale, Wolfgang A; Sharma, Pankaj; Tamagnone, Michele; Mosig, Juan R; Ionescu, Adrian M

    2016-08-10

    Graphene quantum capacitors (GQC) are demonstrated to be enablers of radio-frequency (RF) functions through voltage-tuning of their capacitance. We show that GQC complements MEMS and MOSFETs in terms of performance for high frequency analog applications and tunability. We propose a CMOS compatible fabrication process and report the first experimental assessment of their performance at microwaves frequencies (up to 10 GHz), demonstrating experimental GQCs in the pF range with a tuning ratio of 1.34:1 within 1.25 V, and Q-factors up to 12 at 1 GHz. The figures of merit of graphene variable capacitors are studied in detail from 150 to 350 K. Furthermore, we describe a systematic, graphene specific approach to optimize their performance and predict the figures of merit achieved if such a methodology is applied.

  20. Shallow PS-logging by high frequency wave; Koshuha wo mochiita senbu PS kenso

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, A.; Miyazawa, M.; Azuma, H. [OYO Corp., Tokyo (Japan)

    1996-05-01

    This paper describes the following matters on down-hole PS logging in shallow subsurface. Determining an elastic wave velocity structure in shallow subsurface with high accuracy by using down-hole PS logging requires reduction of errors in reading travel time. Therefore, a high-frequency vibration source was fabricated with an objective to raise frequencies of waves used for the measurement. Measurements were made on two holes, A and B, at a measurement interval of 0.5 m, whereas at the hole A a measurement was performed simultaneously by using a normal type (low-frequency) vibration source. A spectral analysis on the waveform record revealed that the frequencies with each vibration source were 127 Hz and 27 Hz for the hole A, 115 Hz for the hole B, and the S/N ratio was all the same for both holes. When the high-frequency vibration source was used, the velocity was determined at accuracy of 5% over the whole length of the shallow section. When the low-frequency vibration source was used, sections with the velocity determining error greater than 5% were found, and it was not possible to derive the velocity structure in the shallow subsurface in fine segments. 3 refs., 8 figs., 2 tabs.

  1. Mid- to high-frequency noise from high-speed boats and its potential impacts on humpback dolphins.

    Science.gov (United States)

    Li, Songhai; Wu, Haiping; Xu, Youhou; Peng, Chongwei; Fang, Liang; Lin, Mingli; Xing, Luru; Zhang, Peijun

    2015-08-01

    The impact of noise made by vessels on marine animals has come under increased concern. However, most measurements on noise from vessels have only taken into account the low-frequency components. For cetaceans operating in the mid- and high-frequencies, such as the Indo-Pacific humpback dolphin (Sousa chinensis), mid- to high-frequency noise components may be of more concern, in terms of their potential impacts. In this study, noise made by a small high-speed boat was recorded using a broadband recording system in a dolphin watching area focusing on the effects on humpback dolphins in Sanniang Bay, China. The high-speed boat produced substantial mid- to high-frequency noise components with frequencies to >100 kHz, measured at three speeds: ∼40, 30, and 15 km/h. The noise from the boat raised the ambient noise levels from ∼5 to 47 decibels (dB) root-mean-square (rms) across frequency bands ranging from 1 to 125 kHz at a distance of 20 to 85 m, with louder levels recorded at higher speeds and at closer distances. To conclude, the noise produced by the small high-speed boat could be heard by Sousa chinensis and therefore potentially had adverse effects on the dolphins.

  2. Non-destructive plasma frequency measurement for a semiconductor thin film using broadband surface plasmon polaritons

    Science.gov (United States)

    Yang, Tao; Ge, Jia-cheng; Li, Xing-ao; Stantchev, Rayko Ivanov; Zhu, Yong-yuan; Zhou, Yuan; Huang, Wei

    2018-03-01

    Measurement of the plasma frequency of a semiconductor film using broadband surface plasmon is demonstrated in this paper. We theoretically deduce a formula about the relation between plasma frequency and characteristic surface plasmon frequency. The characteristic surface plasmon frequency can be captured from the cut-off frequency of the transmission spectra of the broadband surface plasmon, which is used to measure the plasma frequency indirectly. The plasma frequencies of an intrinsic indium antimonide with and without optical illuminance are measured with a THz time-domain spectrometer at room temperature. The experimental measured plasma frequencies fit well with theoretical and simulation results. Compared with other methods, the proposed method has a special advantage on measuring the plasma frequency for a thin semiconductor film coated on other materials.

  3. A High Reliability Frequency Stabilized Semiconductor Laser Source Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Ultrastable, narrow linewidth, high reliability MOPA sources are needed for high performance LIDARs in NASA for, wind speed measurement, surface topography and earth...

  4. Dynamic pressure probe response tests for robust measurements in periodic flows close to probe resonating frequency

    Science.gov (United States)

    Ceyhun Şahin, Fatma; Schiffmann, Jürg

    2018-02-01

    A single-hole probe was designed to measure steady and periodic flows with high fluctuation amplitudes and with minimal flow intrusion. Because of its high aspect ratio, estimations showed that the probe resonates at a frequency two orders of magnitude lower than the fast response sensor cut-off frequencies. The high fluctuation amplitudes cause a non-linear behavior of the probe and available models are neither adequate for a quantitative estimation of the resonating frequencies nor for predicting the system damping. Instead, a non-linear data correction procedure based on individual transfer functions defined for each harmonic contribution is introduced for pneumatic probes that allows to extend their operating range beyond the resonating frequencies and linear dynamics. This data correction procedure was assessed on a miniature single-hole probe of 0.35 mm inner diameter which was designed to measure flow speed and direction. For the reliable use of such a probe in periodic flows, its frequency response was reproduced with a siren disk, which allows exciting the probe up to 10 kHz with peak-to-peak amplitudes ranging between 20%–170% of the absolute mean pressure. The effect of the probe interior design on the phase lag and amplitude distortion in periodic flow measurements was investigated on probes with similar inner diameters and different lengths or similar aspect ratios (L/D) and different total interior volumes. The results suggest that while the tube length consistently sets the resonance frequency, the internal total volume affects the non-linear dynamic response in terms of varying gain functions. A detailed analysis of the introduced calibration methodology shows that the goodness of the reconstructed data compared to the reference data is above 75% for fundamental frequencies up to twice the probe resonance frequency. The results clearly suggest that the introduced procedure is adequate to capture non-linear pneumatic probe dynamics and to

  5. Measuring coral size-frequency distribution using stereo video technology, a comparison with in situ measurements.

    Science.gov (United States)

    Turner, Joseph A; Polunin, Nicholas V C; Field, Stuart N; Wilson, Shaun K

    2015-05-01

    Coral colony size-frequency distribution data offer valuable information about the ecological status of coral reefs. Such data are usually collected by divers in situ, but stereo video is being increasingly used for monitoring benthic marine communities and may be used to collect size information for coral colonies. This study compared the size-frequency distributions of coral colonies obtained by divers measuring colonies 'in situ' with digital video imagery collected using stereo video and later processed using computer software. The size-frequency distributions of the two methods were similar for corymbose colonies, although distributions were different for massive, branching and all colonies combined. The differences are mainly driven by greater abundance of colonies >50 cm and fewer colonies 5 cm and was able to record measurements on 87% of the colonies detected. However, stereo video only detected 57% of marked colonies coral recruits. Estimates of colony size made with the stereo video were smaller than the in situ technique for all growth forms, particularly for massive morphologies. Despite differences in size distributions, community assessments, which incorporated genera, growth forms and size, were similar between the two techniques. Stereo video is suitable for monitoring coral community demographics and provided data similar to in situ measure for corymbose corals, but the ability to accurately measure massive and branching coral morphologies appeared to decline with increasing colony size.

  6. Accurate modeling of high frequency microelectromechanical systems (MEMS switches in time- and frequency-domainc

    Directory of Open Access Journals (Sweden)

    F. Coccetti

    2003-01-01

    Full Text Available In this contribution we present an accurate investigation of three different techniques for the modeling of complex planar circuits. The em analysis is performed by means of different electromagnetic full-wave solvers in the timedomain and in the frequency-domain. The first one is the Transmission Line Matrix (TLM method. In the second one the TLM method is combined with the Integral Equation (IE method. The latter is based on the Generalized Transverse Resonance Diffraction (GTRD. In order to test the methods we model different structures and compare the calculated Sparameters to measured results, with good agreement.

  7. A Simplified Analytical Technique for High Frequency Characterization of Resonant Tunneling Diode

    Directory of Open Access Journals (Sweden)

    DESSOUKI, A. A. S.

    2014-11-01

    Full Text Available his paper proposes a simplified analytical technique for high frequency characterization of the resonant tunneling diode (RTD. An equivalent circuit of the RTD that consists of a parallel combination of conductance, G (V, f, and capacitance, C (V, f is formulated. The proposed approach uses the measured DC current versus voltage characteristic of the RTD to extract the equivalent circuit elements parameters in the entire bias range. Using the proposed analytical technique, the frequency response - including the high frequency range - of many characteristic aspects of the RTD is investigated. Also, the maximum oscillation frequency of the RTD is calculated. The results obtained have been compared with those concluded and reported in the literature. The reported results in literature were obtained through simulation of the RTD at high frequency using either a computationally complicated quantum simulator or through difficult RF measurements. A similar pattern of results and highly concordant conclusion are obtained. The proposed analytical technique is simple, correct, and appropriate to investigate the behavior of the RTD at high frequency. In addition, the proposed technique can be easily incorporated into SPICE program to simulate circuits containing RTD.

  8. High and low frequency subharmonic imaging of angiogenesis in a murine breast cancer model

    OpenAIRE

    Dahibawkar, Manasi; Forsberg, Mark A.; Gupta, Aditi; Jaffe, Samantha; Dulin, Kelly; Eisenbrey, John R.; Halldorsdottir, Valgerdur G.; Forsberg, Anya I.; Dave, Jaydev K.; Marshall, Andrew; Machado, Priscilla; Fox, Traci B.; Liu, Ji-Bin; Forsberg, Flemming

    2015-01-01

    This project compared quantifiable measures of tumor vascularity obtained from contrast-enhanced high frequency (HF) and low frequency (LF) subharmonic ultrasound imaging (SHI) to 3 immunohistochemical markers of angiogenesis in a murine breast cancer model (since angiogenesis is an important marker of malignancy and the target of many novel cancer treatments). Nineteen athymic, nude, female rats were implanted with 5×106 breast cancer cells (MDA-MB-231) in the mammary fat pad. The contrast a...

  9. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    OpenAIRE

    Yong-Nong, C.; K. Chih-Ming

    2013-01-01

    In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The power supply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to the indispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer need considering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, but also parasitic capacitance resulted fr...

  10. Frequency stability measurement of pulsed superradiance from strontium

    Science.gov (United States)

    Norcia, Matthew; Cline, Julia; Robinson, John; Ye, Jun; Thompson, James

    2017-04-01

    Superradiant laser light from an ultra-narrow optical transition holds promise as a next-generation of active frequency references. We have recently demonstrated pulsed lasing on the milliHertz linewidth clock transition in strontium. Here, we present the first frequency comparisons between such a superradiant source and a state of the art stable laser system. We characterize the stability of the superradiant system, and demonstrate a reduction in sensitivity to cavity frequency fluctuations of nearly five orders of magnitude compared to a conventional laser. DARPA QUASAR, NIST, NSF PFC.

  11. A Realized Variance for the Whole Day Based on Intermittent High-Frequency Data

    DEFF Research Database (Denmark)

    Hansen, Peter Reinhard; Lunde, Asger

    2005-01-01

    We consider the problem of deriving an empirical measure of daily integrated variance (IV) in the situation where high-frequency price data are unavailable for part of the day. We study three estimators in this context and characterize the assumptions that justify their use. We show that the opti......We consider the problem of deriving an empirical measure of daily integrated variance (IV) in the situation where high-frequency price data are unavailable for part of the day. We study three estimators in this context and characterize the assumptions that justify their use. We show...

  12. National High Frequency Radar Network (hfrnet) and Pacific Research Efforts

    Science.gov (United States)

    Hazard, L.; Terrill, E. J.; Cook, T.; de Paolo, T.; Otero, M. P.; Rogowski, P.; Schramek, T. A.

    2016-12-01

    The U.S. High Frequency Radar Network (HFRNet) has been in operation for over ten years with representation from 31 organizations spanning academic institutions, state and local government agencies, and private organizations. HFRNet currently holds a collection from over 130 radar installations totaling over 10 million records of surface ocean velocity measurements. HFRNet is a primary example of inter-agency and inter-institutional partnerships for improving oceanographic research and operations. HF radar derived surface currents have been used in several societal applications including coastal search and rescue, oil spill response, water quality monitoring and marine navigation. Central to the operational success of the large scale network is an efficient data management, storage, access, and delivery system. The networking of surface current mapping systems is characterized by a tiered structure that extends from the individual field installations to local regional operations maintaining multiple sites and on to centralized locations aggregating data from all regions. The data system development effort focuses on building robust data communications from remote field locations (sites) for ingestion into the data system via data on-ramps (Portals or Site Aggregators) to centralized data repositories (Nodes). Centralized surface current data enables the aggregation of national surface current grids and allows for ingestion into displays, management tools, and models. The Coastal Observing Research and Development Center has been involved in international relationships and research in the Philippines, Palau, and Vietnam. CORDC extends this IT architecture of surface current mapping data systems leveraging existing developments and furthering standardization of data services for seamless integration of higher level applications. Collaborations include the Philippine Atmospheric Geophysical and Astronomical Services Administration (PAGASA), The Coral Reef Research

  13. Robust Optimization Design Algorithm for High-Frequency TWTs

    Science.gov (United States)

    Wilson, Jeffrey D.; Chevalier, Christine T.

    2010-01-01

    Traveling-wave tubes (TWTs), such as the Ka-band (26-GHz) model recently developed for the Lunar Reconnaissance Orbiter, are essential as communication amplifiers in spacecraft for virtually all near- and deep-space missions. This innovation is a computational design algorithm that, for the first time, optimizes the efficiency and output power of a TWT while taking into account the effects of dimensional tolerance variations. Because they are primary power consumers and power generation is very expensive in space, much effort has been exerted over the last 30 years to increase the power efficiency of TWTs. However, at frequencies higher than about 60 GHz, efficiencies of TWTs are still quite low. A major reason is that at higher frequencies, dimensional tolerance variations from conventional micromachining techniques become relatively large with respect to the circuit dimensions. When this is the case, conventional design- optimization procedures, which ignore dimensional variations, provide inaccurate designs for which the actual amplifier performance substantially under-performs that of the design. Thus, this new, robust TWT optimization design algorithm was created to take account of and ameliorate the deleterious effects of dimensional variations and to increase efficiency, power, and yield of high-frequency TWTs. This design algorithm can help extend the use of TWTs into the terahertz frequency regime of 300-3000 GHz. Currently, these frequencies are under-utilized because of the lack of efficient amplifiers, thus this regime is known as the "terahertz gap." The development of an efficient terahertz TWT amplifier could enable breakthrough applications in space science molecular spectroscopy, remote sensing, nondestructive testing, high-resolution "through-the-wall" imaging, biomedical imaging, and detection of explosives and toxic biochemical agents.

  14. Design of 1 MHz Solid State High Frequency Power Supply

    Science.gov (United States)

    Parmar, Darshan; Singh, N. P.; Gajjar, Sandip; Thakar, Aruna; Patel, Amit; Raval, Bhavin; Dhola, Hitesh; Dave, Rasesh; Upadhay, Dishang; Gupta, Vikrant; Goswami, Niranjan; Mehta, Kush; Baruah, Ujjwal

    2017-04-01

    High Frequency Power supply (HFPS) is used for various applications like AM Transmitters, metallurgical applications, Wireless Power Transfer, RF Ion Sources etc. The Ion Source for a Neutral beam Injector at ITER-India uses inductively coupled power source at High Frequency (∼1 MHz). Switching converter based topology used to generate 1 MHz sinusoidal output is expected to have advantages on efficiency and reliability as compared to traditional RF Tetrode tubes based oscillators. In terms of Power Electronics, thermal and power coupling issues are major challenges at such a high frequency. A conceptual design for a 200 kW, 1 MHz power supply and a prototype design for a 600 W source been done. The prototype design is attempted with Class-E amplifier topology where a MOSFET is switched resonantly. The prototype uses two low power modules and a ferrite combiner to add the voltage and power at the output. Subsequently solution with Class-D H-Bridge configuration have been evaluated through simulation where module design is stable as switching device do not participate in resonance, further switching device voltage rating is substantially reduced. The rating of the modules is essentially driven by the maximum power handling capacity of the MOSFETs and ferrites in the combiner circuit. The output passive network including resonance tuned network and impedance matching network caters for soft switching and matches the load impedance to 50ohm respectively. This paper describes the conceptual design of a 200 kW high frequency power supply and experimental results of the prototype 600 W, 1 MHz source.

  15. Study of switching transients in high frequency converters

    Science.gov (United States)

    Zinger, Donald S.; Elbuluk, Malik E.; Lee, Tony

    1993-01-01

    As the semiconductor technologies progress rapidly, the power densities and switching frequencies of many power devices are improved. With the existing technology, high frequency power systems become possible. Use of such a system is advantageous in many aspects. A high frequency ac source is used as the direct input to an ac/ac pulse-density-modulation (PDM) converter. This converter is a new concept which employs zero voltage switching techniques. However, the development of this converter is still in its infancy stage. There are problems associated with this converter such as a high on-voltage drop, switching transients, and zero-crossing detecting. Considering these problems, the switching speed and power handling capabilities of the MOS-Controlled Thyristor (MCT) makes the device the most promising candidate for this application. A complete insight of component considerations for building an ac/ac PDM converter for a high frequency power system is addressed. A power device review is first presented. The ac/ac PDM converter requires switches that can conduct bi-directional current and block bi-directional voltage. These bi-directional switches can be constructed using existing power devices. Different bi-directional switches for the converter are investigated. Detailed experimental studies of the characteristics of the MCT under hard switching and zero-voltage switching are also presented. One disadvantage of an ac/ac converter is that turn-on and turn-off of the switches has to be completed instantaneously when the ac source is at zero voltage. Otherwise shoot-through current or voltage spikes can occur which can be hazardous to the devices. In order for the devices to switch softly in the safe operating area even under non-ideal cases, a unique snubber circuit is used in each bi-directional switch. Detailed theory and experimental results for circuits using these snubbers are presented. A current regulated ac/ac PDM converter built using MCT's and IGBT's is

  16. High frequency plant regeneration from mature seedderived callus ...

    African Journals Online (AJOL)

    In the present study, we have developed a high-frequency plant regeneration system for Italian ryegrass via callus culture using mature seeds as explants. Optimal embryogenic callus induction was found to occur in MS medium containing 5 mg l-1 2,4-D, 0.5 mg l-1 BA, 500 mg l-1 L-proline, 1 g l-1 casein hydrolysate, 30 g ...

  17. High frequency plant regeneration from mature seed- derived callus ...

    African Journals Online (AJOL)

    PRECIOUS

    2009-12-15

    Dec 15, 2009 ... In the present study, we have developed a high-frequency plant regeneration system for Italian ryegrass via callus culture using mature seeds as explants. Optimal embryogenic callus induction was found to occur in MS medium containing 5 mg l-1 2,4-D, 0.5 mg l-1 BA, 500 mg l-1 L-proline, 1 g l-1 casein.

  18. Unbalanced heat isolation in high-frequency electrothermics of polymers

    OpenAIRE

    A. V. Livshits

    2014-01-01

    The polymeric materials are widely applied in many industries because they have a number of advantages, which allow their use instead of traditional materials. Nevertheless, the issues of manufacturing products from polymeric materials and their applications are insufficiently studied. The same can be said about high-frequency (HF) electrothermics of polymers. Therefore, mathematical simulation of electrothermic processes is of interest both in terms of science and in terms of applications.Tr...

  19. Automated composite ellipsoid modelling for high frequency GTD analysis

    Science.gov (United States)

    Sze, K. Y.; Rojas, R. G.; Klevenow, F. T.; Scheick, J. T.

    1991-01-01

    The preliminary results of a scheme currently being developed to fit a composite ellipsoid to the fuselage of a helicopter in the vicinity of the antenna location are discussed under the assumption that the antenna is mounted on the fuselage. The parameters of the close-fit composite ellipsoid would then be utilized as inputs into NEWAIR3, a code programmed in FORTRAN 77 for high frequency Geometrical Theory of Diffraction (GTD) Analysis of the radiation of airborne antennas.

  20. A novel high-frequency encoding algorithm for image compression

    Science.gov (United States)

    Siddeq, Mohammed M.; Rodrigues, Marcos A.

    2017-12-01

    In this paper, a new method for image compression is proposed whose quality is demonstrated through accurate 3D reconstruction from 2D images. The method is based on the discrete cosine transform (DCT) together with a high-frequency minimization encoding algorithm at compression stage and a new concurrent binary search algorithm at decompression stage. The proposed compression method consists of five main steps: (1) divide the image into blocks and apply DCT to each block; (2) apply a high-frequency minimization method to the AC-coefficients reducing each block by 2/3 resulting in a minimized array; (3) build a look up table of probability data to enable the recovery of the original high frequencies at decompression stage; (4) apply a delta or differential operator to the list of DC-components; and (5) apply arithmetic encoding to the outputs of steps (2) and (4). At decompression stage, the look up table and the concurrent binary search algorithm are used to reconstruct all high-frequency AC-coefficients while the DC-components are decoded by reversing the arithmetic coding. Finally, the inverse DCT recovers the original image. We tested the technique by compressing and decompressing 2D images including images with structured light patterns for 3D reconstruction. The technique is compared with JPEG and JPEG2000 through 2D and 3D RMSE. Results demonstrate that the proposed compression method is perceptually superior to JPEG with equivalent quality to JPEG2000. Concerning 3D surface reconstruction from images, it is demonstrated that the proposed method is superior to both JPEG and JPEG2000.

  1. Airway Humidification During High-Frequency Percussive Ventilation

    Science.gov (United States)

    2009-03-01

    Association for Respi- ratory Care (AARC) recommendations for the minimum acceptable heating and humidification during mechanical ventilation ( 30°C...Care. AARC clinical practice guideline: humidification during mechanical ventilation . Respir Care 1992;37(8):887-890. 3. Branson RD. The effects of...Airway Humidification During High-Frequency Percussive Ventilation Patrick F Allan MD, Michael J Hollingsworth CRT, Gordon C Maniere CRT, Anthony K

  2. High-Frequency-Trading: Zwischen Nutzeffekten und Risiken

    OpenAIRE

    Gomber, Peter

    2011-01-01

    Die Mehrheit der auf High Frequency Trading basierenden Strategien trägt zur Marktliquidität (Market-Making-Strategien) oder zur Preisfindung und Markteffizienz (Arbitrage-Strategien) bei. Eine ungeeignete Regulierung dieser Strategien oder eine Beeinträchtigung der zugrunde liegenden Geschäftsmodelle durch übermäßige Belastungen kann kontraproduktiv sein und unvorhergesehene Auswirkungen auf die Marktqualität haben. Allerdings muss jede missbräuchliche Strategie effektiv durch die Aufsichtsb...

  3. Measurement of instrument noise spectra at frequencies below 1 hertz

    Science.gov (United States)

    Snare, R. C.; Mcpherron, R. L.

    1973-01-01

    The use of peak-to-peak values in describing output noise of a magnetometer or low frequency amplifier is of questionable value for certain applications. A more precise statement of instrument noise is made with a plot of the noise power spectral density vs frequency. The spectral density plot provides a rich source of information which can be used in the selection and testing of such instrumentation.

  4. High-frequency EPR on high-spin transition-metal sites

    NARCIS (Netherlands)

    Mathies, Guinevere

    2012-01-01

    The electronic structure of transition-metal sites can be probed by electron-paramagnetic-resonance (EPR) spectroscopy. The study of high-spin transition-metal sites benefits from EPR spectroscopy at frequencies higher than the standard 9.5 GHz. However, high-frequency EPR is a developing field. In

  5. Method and apparatus for measuring the droplet frequency response of an ink-jet print head

    Science.gov (United States)

    Lian, Zhi-Ru; Lee, Ming-Ling; Lai, Yi-Hsuan; Hu, Hung-Lien; Wang, Chiehwen

    2000-06-01

    To speed up the printing speed of an inkjet printer, the manufacturers normally focus on increasing the droplet frequency response. Hence, it has become a very important technique to measure the droplet frequency response of an inkjet printhead. A magneto-electric method is proposed to measure the droplet frequency response. The magneto-electric apparatus contains a metallic detecting plate and a magnetic ring with a gap of about 100 micrometers filled with a nonmagnetic insulating material. The magnetic ring itself is made of a high-permeability alloy consisting of about 78% nickel and 22% iron. When an ink drop jetted from a nozzle makes a contact with the metallic detecting plate, which is perpendicular to the nozzle plate of a printhead, a current is conducted through the detecting plate immediately, and detected as a portion of expected signal. The expected signal is then processed by a signal processing circuit for counting the number of jetted drops, and determining the maximum droplet frequency response of the inkjet printhead as a function of the driving frequency of an applied voltage across the printhead.

  6. Accurate Estimation of Low Fundamental Frequencies from Real-Valued Measurements

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2013-01-01

    In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason for this is that the......In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason...... for this is that they employ asymptotic approximations that are violated when the harmonics are not well-separated in frequency, something that happens when the observed signal is real-valued and the fundamental frequency is low. To mitigate this, we analyze the problem and present some exact fundamental frequency estimators...... that are aimed at solving this problem. These esti- mators are based on the principles of nonlinear least-squares, harmonic fitting, optimal filtering, subspace orthogonality, and shift-invariance, and they all reduce to already published methods for a high number of observations. In experiments, the methods...

  7. High Sensitivity Very Low Frequency Receiver for Earthquake Data Acquisition.

    Science.gov (United States)

    Munir, A.; Najmurrokhman, A.

    2017-03-01

    high sensitivity very low frequency (VLF) receiver is developed based on AD744 monolithic operational amplifier (Op-Amp) for earthquake data acquisition. In research related natural phenomena such as atmospheric noise, lightning and earthquake, a VLF receiver particularly with high sensitivity is utterly required due to the low power of VLF wave signals received by the antenna. The developed receiver is intended to have high sensitivity reception for the signals in frequency range of 10-30kHz allocated for earthquake observation. The VLF receiver which is portably designed is also equipped with an output port connectable to the soundcard of personal computer for further data acquisition. After obtaining the optimum design, the hardware realization is implemented on a printed circuit board (PCB) for experimental characterization. It shows that the sensitivity of realized VLF receiver is almost linear in the predefined frequency range for the input signals lower than -12dBm and to be quadratic for the higher level input signals.

  8. Planck 2013 results. VI. High Frequency Instrument data processing

    CERN Document Server

    Ade, P.A.R.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J. -P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J.J.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Boulanger, F.; Bowyer, J.W.; Bridges, M.; Bucher, M.; Burigana, C.; Cardoso, J. -F.; Catalano, A.; Chamballu, A.; Chary, R. -R.; Chen, X.; Chiang, L. -Y; Chiang, H.C.; Christensen, P.R.; Church, S.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J. -M.; Désert, F. -X.; Dickinson, C.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Enßlin, T.A.; Eriksen, H.K.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A.A.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giardino, G.; Girard, D.; Giraud-Héraud, Y.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.; Helou, G.; Henrot-Versillé, S.; Herent, O.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hou, Z.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, T.R.; Jaffe, A.H.; Jones, W.C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J. -M.; Lasenby, A.; Laureijs, R.J.; Lawrence, C.R.; Jeune, M. Le; Leonardi, R.; Leroy, C.; Lesgourgues, J.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; MacTavish, C.J.; Maffei, B.; Mandolesi, N.; Maris, M.; Marshall, D.J.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; Matthai, F.; Mazzotta, P.; McGehee, P.; Meinhold, P.R.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M. -A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Mottet, S.; Munshi, D.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; North, C.; Noviello, F.; Novikov, D.; Novikov, I.; Orieux, F.; Osborne, S.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paladini, R.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J. -L.; Rachen, J.P.; Racine, B.; Reach, W.T.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sanselme, L.; Santos, D.; Sauvé, A.; Savini, G.; Shellard, E.P.S.; Spencer, L.D.; Starck, J. -L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sureau, F.; Sutton, D.; Suur-Uski, A. -S.; Sygnet, J. -F.; Tauber, J.A.; Tavagnacco, D.; Techene, S.; Terenzi, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L.A.; Wandelt, B.D.; White, S.D.M.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-01-01

    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (hereafter HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857 GHz with an angular resolution ranging from 9.7 to 4.6 arcmin. The detector noise per (effective) beam solid angle is respectively, 10, 6, 12 and 39 microKelvin in HFI four lowest frequency channel (100--353 GHz) and 13 and 14 kJy/sr for the 545 and 857 GHz channels. Using the 143 GHz channel as a reference, these two high frequency channels are intercalibrated within 5% and the 353 GHz relative calibration is at the percent level. The 100 and 217 GHz channels, which together with the 143 GHz channel determine the high-multipole part of the CMB power spectrum (50 < l <2500), are intercalibrated at better than 0.2 %.

  9. High-resolution mid-IR spectrometer based on frequency upconversion

    DEFF Research Database (Denmark)

    Hu, Qi; Dam, Jeppe Seidelin; Pedersen, Christian

    2012-01-01

    We demonstrate a novel approach for high-resolution spectroscopy based on frequency upconversion and postfiltering by means of a scanning Fabryx2013;Perot interferometer. The system is based on sum-frequency mixing, shifting the spectral content from the mid-infrared to the near-visible region al......-frequency 1064xA0;nm laser. We investigate water vapor emission lines from a butane burner and compare the measured results to model data. The presented method we suggest to be used for real-time monitoring of specific gas lines and reference signals....

  10. The Physics of Ultrabroadband Frequency Comb Generation and Optimized Combs for Measurements in Fundamental Physics

    Science.gov (United States)

    2016-07-02

    order phase-matched cascaded frequency gene, high harmonic generation, fine structure constant measurements, -envelope phase stabilization, ultra fast...partially) coherent seed. Figure 1: Experimental Setup used Our experiments showed control of both the spectral and noise properties of optical fibre...specifically linked to the studies funded by the grant are: D. M. Nguyen, T. Godin, S. Toenger, Y. Combes, B. Wetzel, T. Sylvestre, et al

  11. High-precision, accurate optical frequency reference using a Fabry-Perót diode laser

    Science.gov (United States)

    Chang, Hongrok; Myneni, Krishna; Smith, David D.; Liaghati-Mobarhan, Hassan R.

    2017-06-01

    We show that the optical output of a temperature and current-tuned Fabry-Perót diode laser system, with no external optical feedback and in which the frequency is locked to Doppler-free hyperfine resonances of the 87Rb D2 line, can achieve high frequency stability and accuracy. Experimental results are presented for the spectral linewidth, frequency stability, and frequency accuracy of the source. Although our optical source is limited by a short-term spectral linewidth greater than 2 MHz, beat signal measurements from two such sources demonstrate a frequency stability of 1.1 kHz, or minimum Allan deviation of 4 ×1 0-12, at an integration time τ =15 s and with a frequency accuracy of 60 kHz at τ =300 s. We demonstrate the use of the optical source for the precision measurement of hyperfine level frequency spacings in the 5 P3 /2 excited state of 87Rb and provide an accurate frequency scale for optical spectroscopy.

  12. High-temperature, high-frequency fretting fatigue of a single crystal nickel alloy

    Science.gov (United States)

    Matlik, John Frederick

    Fretting is a structural damage mechanism arising from a combination of wear, corrosion, and fatigue between two nominally clamped surfaces subjected to an oscillatory loading. A critical location for fretting induced damage has been identified at the blade/disk and blade/damper interfaces of gas turbine engine turbomachinery and space propulsion components. The high-temperature, high-frequency loading environment seen by these components lead to severe stress gradients at the edge-of-contact that could potentially foster crack growth leading to component failure. These contact stresses drive crack nucleation in fretting and are very sensitive to the geometry of the contacting bodies, the contact loads, materials, temperature, and contact surface tribology (friction). To diagnose the threat that small and relatively undetectable fretting fatigue cracks pose to damage tolerance and the ensuing structural integrity of aerospace components, a strong motivation exists to develop a quantitative mechanics based understanding of fretting crack nucleation in advanced aerospace alloys. In response to this need, the objective of this work is to characterize the fretting behavior exhibited by a polycrystalline/single crystal nickel contact subjected to elevated frequency and temperature. The effort to meet this objective is two fold: (1) to develop a well-characterized experimental fretting rig to investigate fretting behavior of advanced aerospace alloys at high frequency and high temperature, and (2) to develop the associated contact modeling tools for calculating contact stresses given in-situ experimentally measured remote contact loads. By coupling the experimental results and stress analysis, this effort aims to correlate the fretting crack nucleation behavior with the local contact stresses calculated from the devised three dimensional, anisotropic, dissimilar material contact model. The experimental effort is first motivated by a survey of recent fretting issues and

  13. Comparison of time and frequency domain measures of RSA in ambulatory recordings.

    Science.gov (United States)

    Goedhart, Annebet D; van der Sluis, Sophie; Houtveen, Jan H; Willemsen, Gonneke; de Geus, Eco J C

    2007-03-01

    The extent to which various measures of ambulatory respiratory sinus arrhythmia (RSA) capture the same information across conditions in different subjects remains unclear. In this study the root mean square of successive differences (RMSSD), peak valley RSA (pvRSA), and high frequency power (HF power) were assessed during ambulatory recording in 84 subjects, of which 64 were retested after about 3 years. We used covariance structure modeling to test the equality of the correlations among three RSA measures over two test days and three conditions (daytime sitting or walking and nighttime sleep) and in groups with low, medium, and high mean heart rate (HR), or low, medium, and high mean respiration rate (RR). Results showed that ambulatory RMSSD, pvRSA, and HF power are highly correlated and that their correlation is stable across time, ambulatory conditions, and a wide range of resting HR and RR values. RMSSD appears to be the most cost-efficient measure of RSA.

  14. Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL.

    Science.gov (United States)

    Mehrparvar, Amir Houshang; Mirmohammadi, Seyyed Jalil; Davari, Mohammad Hossein; Mostaghaci, Mehrdad; Mollasadeghi, Abolfazl; Bahaloo, Maryam; Hashemi, Seyyed Hesam

    2014-01-01

    Noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies. This study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission). This was a cross-sectional study. Data was analyzed by SPSS (ver. 19) using chi square, T test and repeated measures analysis. Study samples were workers from tile and ceramic industry. We found that conventional audiometry, extended high-frequency audiometry, low-tone distortion product otoacoustic emission and high-tone distortion product otoacoustic emission had abnormal findings in 29 %, 69 %, 22 %, and 52 % of participants. Most frequently affected frequencies were 4000 and 6000Hz in conventional audiometry, and 14000 and 16000 in extended high-frequency audiometry. Extended high-frequency audiometry was the most sensitive test for detection of hearing loss in workers exposed to hazardous noise compared with conventional audiometry and distortion product otoacoustic.

  15. Tunable-frequency high-field electron paramagnetic resonance

    Science.gov (United States)

    Krzystek, J.; Zvyagin, S. A.; Ozarowski, Andrew; Trofimenko, S.; Telser, Joshua

    2006-02-01

    A tunable-frequency methodology based on backward wave oscillator sources in high-frequency and -field EPR (HFEPR) is described. This methodology is illustrated by an application to three non-Kramers transition metal ion complexes and one Kramers ion complex. The complexes are of: Ni(II) ( S = 1) as found in dichlorobistriphenylphosphanenickel(II), Mn(III) ( S = 2) as found in mesotetrasulfonatoporphyrinatomanganese(III) chloride, Fe(II) ( S = 2) as found in ferrous sulfate tetrahydrate, and Co(II) ( S = 3/2) as found in azido(tris(3- tert-butylpyrazol-1-yl)hydroborate)cobalt(II). The above Ni(II) and Mn(III) complexes have been studied before by HFEPR using the multifrequency methodology based on Gunn oscillator sources, but not by the present method, while the Fe(II) and Co(II) complexes presented here have not been studied by any form of HFEPR. Highly accurate spin Hamiltonian parameters can be obtained by the experimental methodology described here, in combination with automated fitting procedures. This method is particularly successful in determining g-matrix parameters, which are very difficult to extract for high-spin systems from single frequency (or a very limited set of multi-frequency) HFEPR spectra, but is also able to deliver equally accurate values of the zero-field splitting tensor. The experimental methods involve either conventional magnetic field modulation or an optical modulation of the sub-THz wave beam. The relative merits of these and other experimental methods are discussed.

  16. Application of length vernier in phase coincidence detection and precision frequency measurement.

    Science.gov (United States)

    Miao, Miao; Wei, Zhou; Bin, Wang

    2012-02-01

    For comparison of arbitrary frequency signals, the paper proposed two levels of length vernier based on the time-space relationship are used in three levels of phase coincidence detecting circuits to extract the phase coincidence information by proper logic calculation. The length∕phase of each vernier is respectively corresponding to the accuracy and the resolution of detecting circuit. The time-space relationship is based on high-stability, high-accuracy, and high-speed of signal transmission. The method is effective to reduce the fuzzy region in the phase coincidence information and reach a higher measuring precision.

  17. Long range ultra-high frequency (UHF) radio frequency identification (RFID) antenna design

    Science.gov (United States)

    Reynolds, Nathan D.

    There is an ever-increasing demand for radio frequency identification (RFID) tags that are passive, long range, and mountable on multiple surfaces. Currently, RFID technology is utilized in numerous applications such as supply chain management, access control, and public transportation. With the combination of sensory systems in recent years, the applications of RFID technology have been extended beyond tracking and identifying. This extension includes applications such as environmental monitoring and healthcare applications. The available sensory systems usually operate in the medium or high frequency bands and have a low read range. However, the range limitations of these systems are being overcome by the development of RFID sensors focused on utilizing tags in the ultra-high frequency (UHF) band. Generally, RFID tags have to be mounted to the object that is being identified. Often the objects requiring identification are metallic. The inherent properties of metallic objects have substantial effects on nearby electromagnetic radiation; therefore, the operation of the tag antenna is affected when mounted on a metallic surface. This outlines one of the most challenging problems for RFID systems today: the optimization of tag antenna performance in a complex environment. In this research, a novel UHF RFID tag antenna, which has a low profile, long range, and is mountable on metallic surfaces, is designed analytically and simulated using a 3-D electromagnetic simulator, ANSYS HFSS. A microstrip patch antenna is selected as the antenna structure, as patch antennas are low profile and suitable for mounting on metallic surfaces. Matching and theoretical models of the microstrip patch antenna are investigated. Once matching and theory of a microstrip patch antenna is thoroughly understood, a unique design technique using electromagnetic band gap (EBG) structures is explored. This research shows that the utilization of an EBG structure in the patch antenna design yields

  18. High-frequency radar observations of PMSE modulation by radio heating

    Science.gov (United States)

    Senior, Andrew; Rietveld, Michael; Mahmoudian, Alireza; La Hoz, Cesar; Kosch, Michael; Scales, Wayne; Pinedo, Henry

    The first observations using high-frequency (8 MHz) radar of modulation of polar mesospheric summer echoes (PMSE) by radio heating of the ionosphere are presented. The experiment was performed at the EISCAT facility near Tromsø, Norway. The observations are compared with simultaneous radar measurements at 224 MHz and with a model of the dusty plasma response to electron heating. Agreement between the model and observations is good considering technical limitations on the 8 MHz radar measurements. Predictions made about the response of high-frequency PMSE to heating where dust charging dominates over diffusion, opposite to the situation at very high-frequencies are confirmed. Suggestions are made about improving the 8 MHz observations to overcome the current limitations.

  19. On-chip photonic-assisted instantaneous microwave frequency measurement system

    NARCIS (Netherlands)

    Marpaung, D.A.I.

    2013-01-01

    A novel instantaneous frequency measurement system based on a programmable photonic chip frequency discriminator is experimentally demonstrated. The microwave signal whose frequency is to be measured is used to modulate the phase of an optical carrier. An optical ring resonator (ORR) in an add-drop

  20. Very High Frequency Galvanic Isolated Offline Power Supply

    DEFF Research Database (Denmark)

    Pedersen, Jeppe Arnsdorf

    inverters with a single combined rectifier. The converter designed to deliver 9 W to a 60 V LED load and is achieving an efficiency of 89.4% and a power density of 2.14 W3 . The development of this converter proof that offline VHF converter can be implemented with high efficiencies even for low power applications...... converters. During this Ph.D. thesis, different areas of an offline VHF converters are described, dur-ing the project different areas have been investigated such as, gate drive, synchronous rectifiers, PCB transformers, control of a resonant converter, galvanic isolation, EMC performance, power factor......During the last decades many researchers have turned their attention to raising the operation frequency of power converters to the very high frequency (VHF) range going from 30 MHz to 300 MHz. Increasing the operating frequency of a power converter leads to smaller energy storing components...

  1. High-Frequency Quantitative Ultrasound Imaging of Cancerous Lymph Nodes

    Science.gov (United States)

    Mamou, Jonathan; Coron, Alain; Hata, Masaki; Machi, Junji; Yanagihara, Eugene; Laugier, Pascal; Feleppa, Ernest J.

    2009-07-01

    High-frequency ultrasound (HFU) offers a means of investigating biological tissue at the microscopic level. High-frequency, quantitative-ultrasound (QUS) methods were developed to characterize freshly-dissected lymph nodes of cancer patients. Three-dimensional (3D) ultrasound data were acquired from lymph nodes using a 25.6-MHz center-frequency transducer. Each node was inked prior to 3D histological fixation to recover orientation after sectioning. Backscattered echo signals were processed to yield two QUS estimates associated with tissue microstructure: scatterer size and acoustic concentration. The QUS estimates were computed following established methods using a Gaussian scattering model. Four lymph nodes from a patient with stage-3 colon cancer were evaluated as an illustrative case. QUS images were generated for this patient by expressing QUS estimates as color-encoded pixels and overlaying them on conventional gray-scale B-mode images. The single metastatic node had an average scatterer size that was significantly larger than the average scatterer size of the other nodes, and the statistics of both QUS estimates in the metastatic node showed greater variance than the statistics of the other nodes. Results indicate that the methods may provide a useful means of identifying small metastatic foci in dissected lymph nodes that might not be detectable using current standard pathology procedures.

  2. Slow high-frequency effects in mechanics: problems, solutions, potentials

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel

    2005-01-01

    them are introduced first in terms of simple physical examples, and then in generalized form for mathematical models covering broad classes of discrete and continuous mechanical systems. Several application examples are summarized. Three mathematical tools for analyzing HFE effects are described......Strong high-frequency excitation (HFE) may change the ‘slow’ (i.e. effective or average) properties of mechanical systems, e.g. their stiffness, natural frequencies, equilibriums, equilibrium stability, and bifurcation paths. This tutorial describes three general HFE effects: Stiffening...... – an apparent change in the stiffness associated with an equilibrium; Biasing – a tendency for a system to move towards a particular state which does not exist or is unstable without HFE; and Smoothening – a tendency for discontinuities to be apparently smeared out by HFE. The effects and a method for analyzing...

  3. Problems with the graduated frequency approach to measuring alcohol consumption: results from a pilot study in Toronto, Canada.

    Science.gov (United States)

    Graham, Kathryn; Demers, Andrée; Rehm, Jürgen; Gmel, Gerhard

    2004-01-01

    To evaluate advantages and disadvantages of the graduated frequency (GF) approach, which asks about the frequency of alcohol consumption at mutually exclusive quantity levels (i.e. 12 or more drinks, at least eight drinks but less than 12, etc.). Telephone survey of 464 adults aged 18 and older in Toronto, Canada, using random digit dialing and computer-assisted telephone interviewing. Respondents reported higher frequency and volume of drinking on the GF compared to overall and beverage-specific quantity-frequency type measures; however, at least 16% of GF responses included double counting on their frequency estimates using the GF. When these cases were excluded or corrected, differences between the GF and quantity-frequency measures mostly disappeared. The GF was superior to quantity-frequency measures for identifying heavy episodic drinkers. However, the GF had little advantage over the weekly recall method except for identifying very infrequent (i.e. less often than twice a month) heavy drinkers. Because the GF has a high rate of response errors in terms of measuring frequency of alcohol consumption, other combinations of measures, including alternate measures of heavy episodic drinking should be considered.

  4. Dielectric measurements on PWB materials at microwave frequencies

    Indian Academy of Sciences (India)

    Unknown

    microelectronics industry. New packaging technology re- quires substrates with low permittivity. As electrical com- ponents are miniaturized, the .... k = ω /c0 is the free-space propagation vector, where ω is the angular frequency and c0 the velocity of light, c the thickness of the film and. 1. 2. (. ) d. a c. = − , a being the width.

  5. Indoor measurements of low-frequency noise for annoyance assessment

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2007-01-01

    The sound pressure level within a room may vary as much as 20-30 dB at low frequencies. Mainly the highest levels are of concern with regards to annoyance assessment, rather than a room average. The highest levels can however be very difficult to find. Sound fields in rooms were investigated usin...

  6. Dielectric measurements on PWB materials at microwave frequencies

    Indian Academy of Sciences (India)

    In quest of finding new substrate for printed wiring board (PWB) having low dielectric constant, we have made PSF/PMMA blends and evaluated the dielectric parameters at 8.92 GHz frequency and at 35°C temperature. Incorporating PMMA in PSF matrix results in reduced dielectric constant than that of pure PSF.

  7. Optical Measurements of Strong Radio-Frequency Fields Using Rydberg Atoms

    Science.gov (United States)

    Miller, Stephanie Anne

    There has recently been an initiative toward establishing atomic measurement standards for field quantities, including radio-frequency, millimeter-wave, and micro-wave electric fields. Current measurement standards are obtained using dipole antennas, which are fundamentally limited in frequency bandwidth (set by the physical size of the antenna) and accuracy (due to the metal perturbing the field during the measurement). Establishing an atomic standard rectifies these problems. My thesis work contributes to an ongoing effort towards establishing the viability of using Rydberg electromagnetically induced transparency (EIT) to perform atom-based measurements of radio-frequency (RF) fields over a wide range of frequencies and field strengths, focusing on strong-field measurements. Rydberg atoms are atoms with an electron excited to a high principal quantum number, resulting in a high sensitivity to an applied field. A model based on Floquet theory is implemented to accurately describe the observed atomic energy level shifts from which information about the field is extracted. Additionally, the effects due to the different electric field domains within the measurement volume are accurately modeled. Absolute atomic measurements of fields up to 296 V/m within a +/-0.35% relative uncertainty are demonstrated. This is the strongest field measured at the time of data publication. Moreover, the uncertainty is over an order of magnitude better than that of current standards. A vacuum chamber setup that I implemented during my graduate studies is presented and its unique components are detailed. In this chamber, cold-atom samples are generated and Rydberg atoms are optically excited within the ground-state sample. The Rydberg ion detection and imaging procedure are discussed, particularly the high magnification that the system provides. By analyzing the position of the ions, the spatial correlation g(2) (r) of Rydberg-atom distributions can be extracted. Aside from ion

  8. Thermal Loss of High-Q Antennas in Time Domain vs. Frequency Domain Solver

    DEFF Research Database (Denmark)

    Bahramzy, Pevand; Pedersen, Gert Frølund

    2014-01-01

    High-Q structures pose great challenges to their loss simulations in Time Domain Solvers (TDS). Therefore, in this work the thermal loss of high-Q antennas is calculated both in TDS and Frequency Domain Solver (FDS), which are then compared with each other and with the actual measurements....... The thermal loss calculation in FDS is shown to be more accurate for high-Q antennas....

  9. High-power high-frequency DC-to-DC converters

    Energy Technology Data Exchange (ETDEWEB)

    Kheraluwala, M.H.

    1991-01-01

    Three new dc-to-dc converter topologies aimed at high-power high-frequency applications are introduced. Major system parasitics, namely, the leakage inductance of the transformer and the device output capacitance are efficiently utilized. All circuits operate at a constant switching frequency, thus simplifying design of the reactive elements. Of the three circuits the single-phase and three-phase versions of the dual-active-bridge topology demonstrate minimal electrical stresses, better utilization of the transformer, bi-directional and buck-boost model of operation. The power-transfer characteristics and soft-switching regions on the Vout-Iout plane are identified. Two coaxial transformers with different cross-sections were built for a rating of 50 kVA. The measured leakage inductance at 50 kHz is seen to be in the vicinity of 150-250 nH, with power density of approximately 0.1 kg/kW. Based on the single-phase dual-active-bridge topology, a 50kW, 50-kHz converter operating at an input voltage of 200V dc and an output voltage of 1,600V dc was fabricated.

  10. Design, Prototyping and Measurement of a Cascaded 6-GHz Frequency Selective Surface Array

    Directory of Open Access Journals (Sweden)

    Marcelo Bender Perotoni

    2016-04-01

    Full Text Available The design, prototyping, and free-space measurement of a 6-GHz Frequency Selective Surface filter is presented. The prototyping resolution of a large (A4 sheet size Frequency Selective Surface with small loops as elements is checked, as well as the correlation with measurements performed with a 3-D full-wave solver. The test also involved the effect of cascading two different Frequency Selective Surfaces with a viewpoint towards a narrower frequency range, which provided good results.

  11. Application of high frequency ultrasound in the destruction of DDT in contaminated sand and water.

    Science.gov (United States)

    Thangavadivel, Kandasamy; Megharaj, Mallavarapu; Smart, Roger St C; Lesniewski, Peter J; Naidu, Ravi

    2009-09-15

    High frequency ultrasound, as an alternative to high cost incineration, has been investigated to remediate DDT from sand and soil slurries. In this study, low power high frequency ultrasound (1.6 MHz; 150 W/L), with operating costs much lower than low frequency ultrasound, has been used to remediate DDT in liquid solution and in sand slurries. At 1.6 MHz, the wavelength, cycle time, bubble size and bubble life time are much smaller and the number of bubbles per litre is much larger than at frequencies below 50 kHz. These large differences affect the effective mass transfer to the bubbles and subsequent energy release, hydrolysis of water and degradation mechanism. Based on DDT measurement, using high frequency ultrasound, 90% of 8 mg/L of DDT from liquid solution was destroyed in 90 min. Removal efficiency from 32.6 mg/L of DDT in a 40 wt.% sand slurry was 22% in 90 min. Other slurry and DDT combinations are reported. Incremental chloride measurements indicated that combination of ultrasound and iron powder helps to increase the remediation rate of DDT from sand slurry, e.g. 46% cf. 32% for a 20 wt.% slurry. The results show that high frequency ultrasound is effective in degrading the non-polar pollutant DDT dispersed in water and in sand slurry. In practice, due to intensity limitations in currently available equipment and higher attenuation of energy, high frequency ultrasound has a low volume coverage and would require circulation of the slurry past the sonotrode, multiple sonotrodes, larger sonotrode area and lower slurry densities may still be required.

  12. High-frequency field-deployable isotope analyzer for hydrological applications

    Science.gov (United States)

    Elena S.F. Berman; Manish Gupta; Chris Gabrielli; Tina Garland; Jeffrey J. McDonnell

    2009-01-01

    A high-frequency, field-deployable liquid water isotope analyzer was developed. The instrument was deployed for 4 contiguous weeks in the H. J. Andrews Experimental Forest Long-term Ecological Research site in western Oregon, where it was used for real-time measurement of the isotope ratios of precipitation and stream water during three large storm events. We were able...

  13. Pre- and postoperative high-frequency audiometry in otosclerosis. A study of 53 cases

    NARCIS (Netherlands)

    Tange, R. A.; Dreschler, W. A.

    1990-01-01

    A study was carried out to evaluate the results of stapes surgery in 53 cases of otosclerosis. The hearing function was measured pre- and postoperatively by means of conventional and high-frequency audiometry (Demlar 20K). The operative findings of the gradation of otosclerosis were compared with

  14. Estimation of cables’ tension of cable-stayed footbridge using measured natural frequencies

    Directory of Open Access Journals (Sweden)

    Jakiel Przemysław

    2017-01-01

    Full Text Available This paper presents analysis of cables’ tension of steel cable-stayed footbridge using their field-test natural frequencies. A vibration method is usually used for the measured cable tension during the construction of cable systems stiffened with inclined cables. Practical formulas for the vibration method applied herein, mainly based on cable-sag and vertical angle effects (a survey measurement, have been verified on the one-tower steel cable-stayed bridge. The bridge is situated in Sieradz (Poland and it was the structure with the longest span concerning all the cable-stayed bridges in Poland until 1999. The obtained cable axial forces for estimated natural frequencies of low- and high-order modes are verified using FEM models. The final conclusions drawn on the basis of conducted studies can be useful for technical diagnosis, monitoring programs and repair works of similar class of cable-stayed bridges.

  15. Quality ratings of frequency-compressed speech by participants with extensive high-frequency dead regions in the cochlea.

    Science.gov (United States)

    Salorio-Corbetto, Marina; Baer, Thomas; Moore, Brian C J

    2017-02-01

    The objective was to assess the degradation of speech sound quality produced by frequency compression for listeners with extensive high-frequency dead regions (DRs). Quality ratings were obtained using values of the starting frequency (Sf) of the frequency compression both below and above the estimated edge frequency, fe, of each DR. Thus, the value of Sf often fell below the lowest value currently used in clinical practice. Several compression ratios were used for each value of Sf. Stimuli were sentences processed via a prototype hearing aid based on Phonak Exélia Art P. Five participants (eight ears) with extensive high-frequency DRs were tested. Reductions of sound-quality produced by frequency compression were small to moderate. Ratings decreased significantly with decreasing Sf and increasing CR. The mean ratings were lowest for the lowest Sf and highest CR. Ratings varied across participants, with one participant rating frequency compression lower than no frequency compression even when Sf was above fe. Frequency compression degraded sound quality somewhat for this small group of participants with extensive high-frequency DRs. The degradation was greater for lower values of Sf relative to fe, and for greater values of CR. Results varied across participants.

  16. BBO sapphire compound for high-power frequency conversion

    Science.gov (United States)

    Rothhardt, Carolin; Rothhardt, Jan; Klenke, Arno; Peschel, Thomas; Eberhardt, Ramona; Limpert, Jens; Tünnermann, Andreas

    2015-02-01

    Lasers used for diverse applications from industry to fundamental science tend to increasing output powers. Some applications require frequency conversion via nonlinear optical crystals, which suffer from the formation of temperature gradients at high power operation which causes thermal lensing or destruction of the crystal due to tensile stresses. To avoid these unwanted effects we joined a beta barium borate (BBO) crystal with sapphire disks serving as effective heat spreaders due to their high thermal conductivity (thermal conductivity κ = 42 W/Km). Therefore, smooth and flat crystal surfaces were joined by plasma-activated bonding. The joining relies on covalent bonds, which are formed via a condensation reaction of the surfaces which are first connected by Van der Waals forces. The cleaned surfaces are activated by plasma and brought into contact, pressed together and heat treated at a temperature of about 100°C. Special attention has been paid to the cleaning of the surfaces. Therefor the surfaces have been evaluated before and after treatment by means of atomic force microscopy. A stable connection has been formed successfully, which has been tested in a proof of principle experiment and demonstrated efficient second harmonic generation at up to 253 W of input power. Compared to a bare single BBO crystal it could be shown that the temperature within the crystal compound is significantly reduced. Such hybrid structures pave the way for frequency conversion at kilowatts of average power for future high power lasers.

  17. High Frequency Vibration Based Fatigue Testing of Developmental Alloys

    Science.gov (United States)

    Holycross, Casey M.; Srinivasan, Raghavan; George, Tommy J.; Tamirisakandala, Seshacharyulu; Russ, Stephan M.

    Many fatigue test methods have been previously developed to rapidly evaluate fatigue behavior. This increased test speed can come at some expense, since these methods may require non-standard specimen geometry or increased facility and equipment capability. One such method, developed by George et al, involves a base-excited plate specimen driven into a high frequency bending resonant mode. This resonant mode is of sufficient frequency (typically 1200 to 1700 Hertz) to accumulate 107 cycles in a few hours. One of the main limitations of this test method is that fatigue cracking is almost certainly guaranteed to be surface initiated at regions of high stress. This brings into question the validity of the fatigue test results, as compared to more traditional uniaxial, smooth-bar testing, since high stresses are subjecting only a small volume to fatigue damage. This limitation also brings into question the suitability of this method to screen developmental alloys, should their initiation life be governed by subsurface flaws. However, if applicable, the rapid generation of fatigue data using this method would facilitate faster design iterations, identifying more quickly, material and manufacturing process deficiencies. The developmental alloy used in this study was a powder metallurgy boron-modified Ti-6Al-4V, a new alloy currently being considered for gas turbine engine fan blades. Plate specimens were subjected to fully reversed bending fatigue. Results are compared with existing data from commercially available Ti-6Al-4V using both vibration based and more traditional fatigue test methods.

  18. Very High Frequency Half Bridge DC/DC Converter

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    This paper presents the first, off chip, class DE (resonant half bridge) converter working in the Very High Frequency (VHF) range. The benefits of using half bridge circuits both in the inverter and rectifier part of a VHF resonant dc/dc converter are analyzed and design equations for all...... components in the power stage are given. The circuit has been simulated to verify the accuracy of the presented equations and an efficiency of 89% has been shown. A prototype has been implemented with self-oscillating resonant gate drives driving the switches. The prototype has been used to drive an LED...

  19. Very High Frequency Interleaved Self-Oscillating Resonant SEPIC Converter

    DEFF Research Database (Denmark)

    Kovacevic, Milovan; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    This paper describes analysis and design procedure of an interleaved, self-oscillating resonant SEPIC converter, suitable for operation at very high frequencies (VHF) ranging from 30 MHz to 300 MHz. The presented circuit consists of two resonant SEPIC DC-DC converters, and a capacitive...... interconnection network between the switches which provides self-oscillating and interleaved operation. A design approach to ensure zero voltage switching (ZVS) condition of the MOSFET devices is provided. To verify the proposed method, an 11 W, 50 MHz prototype was built using low-cost VDMOS devices...

  20. Coordinate measurement in 2-D and 3-D geometries using frequency scanning interferometry

    CERN Document Server

    Gibson, S M; Howell, David Francis; Mitra, A; Nickerson, R B

    2005-01-01

    Frequency Scanning Interferometry (FSI) has been developed for robust precise distance measurements. We present the reconstruction of two and three dimensional geodetic grids, using simultaneous FSI measurements between grid nodes. The shape of the particle physics tracker inside the ATLAS experiment (currently under construction for the Large Hadron Collider at CERN) will be monitored using a geodetic grid of 842 remotely measured, fibre-coupled interferometers. The challenge is to make precise distance measurements in the hostile, high radiation environment and combine them to reconstruct node coordinates and hence the grid shape in quasi real time to a three dimensional precision of around 10mum. Two and three dimensional prototype grids with adjustable geometries have been measured, demonstrating shape reconstruction to a precision of around 1mum. Error propagation through these grids was studied with different reconstruction models. Grid redundancy allowed the agreement between software models and node c...

  1. A Space-Frequency Data Compression Method for Spatially Dense Laser Doppler Vibrometer Measurements

    Directory of Open Access Journals (Sweden)

    José Roberto de França Arruda

    1996-01-01

    Full Text Available When spatially dense mobility shapes are measured with scanning laser Doppler vibrometers, it is often impractical to use phase-separation modal parameter estimation methods due to the excessive number of highly coupled modes and to the prohibitive computational cost of processing huge amounts of data. To deal with this problem, a data compression method using Chebychev polynomial approximation in the frequency domain and two-dimensional discrete Fourier series approximation in the spatial domain, is proposed in this article. The proposed space-frequency regressive approach was implemented and verified using a numerical simulation of a free-free-free-free suspended rectangular aluminum plate. To make the simulation more realistic, the mobility shapes were synthesized by modal superposition using mode shapes obtained experimentally with a scanning laser Doppler vibrometer. A reduced and smoothed model, which takes advantage of the sinusoidal spatial pattern of structural mobility shapes and the polynomial frequency-domain pattern of the mobility shapes, is obtained. From the reduced model, smoothed curves with any desired frequency and spatial resolution can he produced whenever necessary. The procedure can he used either to generate nonmodal models or to compress the measured data prior to modal parameter extraction.

  2. Modified integration method for amplitude estimation of fundamental frequency measuring signal for power system protection

    Directory of Open Access Journals (Sweden)

    Bajić Vanja N.

    2014-01-01

    Full Text Available The integration method for amplitude estimation of fundamental frequency signal, using appropriate integration interval, can be used when measuring signal is composed of fundamental and high harmonics of order 2n or fundamental and high harmonics of order 3n, n=1,2,3.... It is not possible to find the integration interval to get the integration method which is simultaneous immune to high harmonics of order 2n, 3n, 5n etc.. In this paper, the integration method is modified to get the method which is simultaneous immune to high harmonics of order 2n, 3n and 5n, n=1,2,3.... The obtained method is tested at miscellaneous form of measuring signals using Matlab.

  3. High Frequency Tail Characteristics in the Coastal Waters off Gopalpur, Northwest Bay of Bengal: A Nearshore Modelling Study

    Science.gov (United States)

    Umesh, P. A.; Bhaskaran, Prasad K.; Sandhya, K. G.; Nair, T. M. Balakrishnan

    2017-12-01

    Over the years, continued uncertainty amid - 4 and - 5 frequency exponent representation observed in the slope of the high-frequency tail of a wind-wave frequency spectrum is a major concern. To comprehend the nature of the high-frequency tail an effort has been made to assess the slope of the high-frequency tail with measured data recorded for 3 years off Gopalpur. The study demonstrates that the high-frequency slope of the spectra varied seasonally in the range of n = - 2.13 to - 3.48. The swell and wind sea parameters calculated by separation frequency method, shows that 64.6% of waves were dominant by swell and the rest 34.9% by sea annually. Single, double and multi-peaked spectra occur 12.23, 71.80 and 15.37% annually. To simulate wave spectra, the nested WAM-SWAN model is forced with ERA-Interim winds and 1D wave spectra comparisons, when performed, proved to be encouraging. From the comparisons of measured and theoretical spectra it is concluded that JONSWAP model could not describe the high-frequency tail of measured spectrum, as indicated by the very high Scatter Index ranging from 0.24 to 1.44. Whether there exists a correct slope for the high-frequency tail is still a question. Moreover, the philosophy of a unique slope at any coastal location remains uncertain for the wave modelling community.

  4. Measures of distance between speech signals in the frequency domain

    Science.gov (United States)

    Deseta, D.

    1984-02-01

    The energy density spectra and the time behavior of the autoregressive model of voice signals are studied. The first is a complete representation of the voice signal in the frequency domain, derived from the application of the Fourier transform to the sampled signal. The second is based on a voice signal generation model in which the channel is represented by poles only (resonances). A symmetrical version of the Itakura distance is the best compromise between conflicting requirements.

  5. Transfer Frequency as a Measure of Hospital Capability and Regionalization.

    Science.gov (United States)

    França, Urbano L; McManus, Michael L

    2017-12-01

    To provide metrics for quantifying the capability of hospitals and the degree of care regionalization. Administrative database covering more than 10 million hospital encounters during a 3-year period (2012-2014) in Massachusetts. We calculated the condition-specific probabilities of transfer for all acute care hospitals in Massachusetts and devised two new metrics, the Hospital Capability Index (HCI) and the Regionalization Index (RI), for analyzing hospital systems. The HCI had face validity, accurately differentiating academic, teaching, and community hospitals of varying size. Individual hospital capabilities were clearly revealed in "fingerprints" of their condition-specific transfer behavior. The RI also performed well, with those of specific conditions successfully quantifying the concentration of care arising from regulatory and public health activity. The median RI of all conditions within the Massachusetts health care system was 0.21 (IQR, 0.13-0.36), with a long tail of conditions that were very highly regionalized. Application of the HCI and RI metrics together across the entire state identified the degree of interdependence among its hospitals. Condition-specific transfer activity, as captured in the HCI and RI, provides quantitative measures of hospital capability and regionalization of care. © Health Research and Educational Trust.

  6. Measurement of radio-frequency temporal phase modulation using spectral interferometry

    Science.gov (United States)

    Jachura, Michał; Szczepanek, Jan; Wasilewski, Wojciech; Karpiński, Michał

    2018-02-01

    We present an optical method to measure radio-frequency electro-optic phase modulation profiles by employing spectrum-to-time mapping realized by highly chirped optical pulses. We directly characterize temporal phase modulation profiles of up to 12.5 GHz bandwidth, with temporal resolution comparable to high-end electronic oscilloscopes. The presented optical setup is a valuable tool for direct characterization of complex temporal electro-optic phase modulation profiles, which is indispensable for practical realization of deterministic spectral-temporal reshaping of quantum light pulses.

  7. Emission noise and high frequency cut-off of the Kondo effect in a quantum dot

    Science.gov (United States)

    Delagrange, R.; Basset, J.; Bouchiat, H.; Deblock, R.

    2018-01-01

    By coupling on chip via a resonant circuit a carbon nanotube to a quantum noise detector, a superconductor-insulator-superconductor junction we measure the emission noise of a carbon nanotube quantum dot in the Kondo regime. The signature of the Kondo effect in the current noise is measured for different ratios of the Kondo temperature over the measured frequency and for different asymmetries of the coupling to the contacts and compared to finite frequency quantum noise calculations. Our results point towards the existence of a high frequency cut-off of the electronic emission noise associated with the Kondo resonance. This cut-off frequency is on the order of a few times the Kondo temperature when the electronic system is close to equilibrium, which is the case for a strongly asymmetric coupling. On the other hand, this cut-off is shifted to lower frequencies in a symmetric coupling situation where the bias voltage drives the Kondo state out of equilibrium. We then attribute the low frequency cut-off to voltage-induced spin relaxation.

  8. An induction motor model for high-frequency torsional vibration analysis

    Science.gov (United States)

    Widdle, R. D.; Krousgrill, C. M.; Sudhoff, S. D.

    2006-03-01

    High-frequency torsional oscillations of a 50 horsepower (hp) induction motor are investigated up to approximately 30 kHz. It is experimentally determined that torsional oscillations, due to the switching harmonics of the motor drive, contribute significantly to the torsional oscillation of the output shaft. Two torsional vibration models are developed. One model assumes the rotor to be rigid, while the other has a compliant rotor. The compliant model allows for greater transmission of high-frequency oscillations, and a better prediction of the measured output shaft vibration.

  9. Frequency combs enable rapid and high-resolution multidimensional coherent spectroscopy

    Science.gov (United States)

    Lomsadze, Bachana; Cundiff, Steven T.

    2017-09-01

    Dual laser frequency combs can rapidly measure high-resolution linear absorption spectra. However, one-dimensional linear techniques cannot distinguish the sources of resonances in a mixture of different analytes, nor can they separate inhomogeneous and homogeneous broadening. Here, we overcame these limitations by acquiring high-resolution multidimensional nonlinear coherent spectra with frequency combs. We experimentally differentiated and assigned the Doppler-broadened features of two naturally occurring isotopes of rubidium atoms (87Rb and 85Rb) according to the placement of their hyperfine energy states in a two-dimensional spectrum.

  10. Material control and surveillance for high frequency access vaults project

    Energy Technology Data Exchange (ETDEWEB)

    Longmire, V. L. (Victoria L.); Stevens, R. S. (Rebecca S.); Martinez, B. J. (Benny J.); Butler, G. W. (Gilbert W.); Huang, J. Y. (John Y.); Pickett, C. (Chris); Younkin, J. (James); Dunnigan, Janelle; Gaby, Jane; Lawson, R. (Roger)

    2004-01-01

    The 'Material Control and Surveillance for High Frequency Access Vaults' project sponsored by United States Department of Energy's Office of Security Policy, Policy Integration and Technical Support Program (SO-20.3) focuses on enhancing nuclear materials control and surveillance in vaults that are frequently accessed. The focus of this effort is to improve materials control and accountability (MC&A) while decreasing the operational impact of these activities. Los Alamos and Y-12 have developed a testbed at the Los Alamos National Laboratory for evaluating and demonstrating integrated technologies for use in enhancing materials control and accountability in active nuclear material storage vaults. An update will be provided on the new systems demonstrated in the test-bed including a 'confirmatory cart' for expediting the performance of inventory and radio-frequency actuated video that demonstrates the concept of automated data entry for materials moving between MBA's. The United States Department of Energy's Office of Security Policy, Policy Integration and Technical Support Program (SO-20.3) has sponsored a project where nuclear material inventory, control and surveillance systems are evaluated, developed, and demonstrated in an effort to provide technologies that reduce risk, increase material assurance, and provide cost-efficient alternatives to manpower-intensive physical inventory and surveillance approaches for working (high-frequency-access) vaults. This Fiscal Year has been largely focused on evaluating and developing components of two sub-systems that could be used either separately in nuclear material vaults or as part of a larger integrated system for nuclear materials accountability, control and surveillance.

  11. Electrokinetic particle-electrode interactions at high frequencies

    Science.gov (United States)

    Yariv, Ehud; Schnitzer, Ory

    2013-01-01

    We provide a macroscale description of electrokinetic particle-electrode interactions at high frequencies, where chemical reactions at the electrodes are negligible. Using a thin-double-layer approximation, our starting point is the set of macroscale equations governing the “bounded” configuration comprising of a particle suspended between two electrodes, wherein the electrodes are governed by a capacitive charging condition and the imposed voltage is expressed as an integral constraint. In the large-cell limit the bounded model is transformed into an effectively equivalent “unbounded” model describing the interaction between the particle and a single electrode, where the imposed-voltage condition is manifested in a uniform field at infinity together with a Robin-type condition applying at the electrode. This condition, together with the standard no-flux condition applying at the particle surface, leads to a linear problem governing the electric potential in the fluid domain in which the dimensionless frequency ω of the applied voltage appears as a governing parameter. In the high-frequency limit ω≫1 the flow is dominated by electro-osmotic slip at the particle surface, the contribution of electrode electro-osmosis being O(ω-2) small. That simplification allows for a convenient analytical investigation of the prevailing case where the clearance between the particle and the adjacent electrode is small. Use of tangent-sphere coordinates allows to calculate the electric and flows fields as integral Hankel transforms. At large distances from the particle, along the electrode, both fields decay with the fourth power of distance.

  12. Measuring high-altitude adaptation.

    Science.gov (United States)

    Moore, Lorna G

    2017-11-01

    High altitudes (>8,000 ft or 2,500 m) provide an experiment of nature for measuring adaptation and the physiological processes involved. Studies conducted over the past ~25 years in Andeans, Tibetans, and, less often, Ethiopians show varied but distinct O2 transport traits from those of acclimatized newcomers, providing indirect evidence for genetic adaptation to high altitude. Short-term (acclimatization, developmental) and long-term (genetic) responses to high altitude exhibit a temporal gradient such that, although all influence O2 content, the latter also improve O2 delivery and metabolism. Much has been learned concerning the underlying physiological processes, but additional studies are needed on the regulation of blood flow and O2 utilization. Direct evidence of genetic adaptation comes from single-nucleotide polymorphism (SNP)-based genome scans and whole genome sequencing studies that have identified gene regions acted upon by natural selection. Efforts have begun to understand the connections between the two with Andean studies on the genetic factors raising uterine blood flow, fetal growth, and susceptibility to Chronic Mountain Sickness and Tibetan studies on genes serving to lower hemoglobin and pulmonary arterial pressure. Critical for future studies will be the selection of phenotypes with demonstrable effects on reproductive success, the calculation of actual fitness costs, and greater inclusion of women among the subjects being studied. The well-characterized nature of the O2 transport system, the presence of multiple long-resident populations, and relevance for understanding hypoxic disorders in all persons underscore the importance of understanding how evolutionary adaptation to high altitude has occurred.NEW & NOTEWORTHY Variation in O2 transport characteristics among Andean, Tibetan, and, when available, Ethiopian high-altitude residents supports the existence of genetic adaptations that improve the distribution of blood flow to vital organs

  13. A High Energy and High Efficiency Spectral Shaping Single Frequency Fiber Laser Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase II project proposes a single frequency high energy fiber laser system for coherent Lidar systems for remote sensing. Current state-of-art...

  14. A High Energy and High Efficiency Spectral Shaping Single Frequency Fiber Laser Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase I project proposes a tunable single frequency high energy fiber laser system for coherent Lidar systems for remote sensing. Current state-of-art...

  15. Articulated pipes conveying fluid pulsating with high frequency

    DEFF Research Database (Denmark)

    Jensen, Jakob Søndergaard

    1999-01-01

    Stability and nonlinear dynamics of two articulated pipes conveying fluid with a high-frequency pulsating component is investigated. The non-autonomous model equations are converted into autonomous equations by approximating the fast excitation terms with slowly varying terms. The downward hangin...... is shown to affect the nonlinear behavior of the system, e.g. bifurcation types can change from supercritical to subcritical, creating several coexisting stable solutions and also anti-symmetrical flutter may appear.......Stability and nonlinear dynamics of two articulated pipes conveying fluid with a high-frequency pulsating component is investigated. The non-autonomous model equations are converted into autonomous equations by approximating the fast excitation terms with slowly varying terms. The downward hanging....... An approximate nonlinear solution for small-amplitude flutter oscillations is obtained using a fifth-order multiple scales perturbation method, and large-amplitude oscillations are examined by numerical integration of the autonomous model equations, using a path-following algorithm. The pulsating fluid component...

  16. Breast tissue characterization with high-frequency scanning acoustic microscopy

    Science.gov (United States)

    Kumon, R. E.; Bruno, I.; Heartwell, B.; Maeva, E.

    2004-05-01

    We have performed imaging of breast tissue using scanning acoustic microscopy (SAM) in the range of 25-50 MHz with the goal of accurately and rapidly determining the structure and composition throughout the volume of the samples. In contrast to traditional histological slides, SAM images can be obtained without special preparation, sometimes even without sectioning, but with sufficiently high spatial resolution to give information comparable to surface optical images. As a result, the use of high-frequency SAM at the time of breast lumpectomy to identify disease-free margins has the potential to reduce reoperative rates, patient anxiety, and local recurrence. However, only limited work has been performed to characterize breast tissue in the frequency range above clinical ultrasound devices. The samples are 4-cm2-thick sections (2-3 mm) taken from mastectomies and preserved in formalin. They are placed between two plates and immersed in water during imaging. Attenuation images are acquired by focusing the acoustic beam at the top and bottom of the samples, although better results were obtained for bottom focusing. For purposes of comparison and identification of histological features, acoustical images will be presented along with optical images obtained from the same samples. [Work supported by CIHR.

  17. High-frequency ultrasonic arrays for ocular imaging

    Science.gov (United States)

    Jaeger, M. D.; Kline-Schoder, R. J.; Douville, G. M.; Gagne, J. R.; Morrison, K. T.; Audette, W. E.; Kynor, D. B.

    2007-03-01

    High-resolution ultrasound imaging of the anterior portion of the eye has been shown to provide important information for sizing of intraocular lens implants, diagnosis of pathological conditions, and creation of detailed maps of corneal topography to guide refractive surgery. Current ultrasound imaging systems rely on mechanical scanning of a single acoustic element over the surface of the eye to create the three-dimensional information needed by clinicians. This mechanical scanning process is time-consuming and subject to errors caused by eye movement during the scanning period. This paper describes development of linear ultrasound imaging arrays intended to increase the speed of image acquisition and reduce problems associated with ocular motion. The arrays consist of a linear arrangement of high-frequency transducer elements designed to operate in the 50 - 75 MHz frequency range. The arrays are produced using single-crystal lithium niobate piezoelectric material, thin film electrodes, and epoxy-based acoustic layers. The array elements have been used to image steel test structures and bovine cornea.

  18. Normocapnic high frequency oscillatory hyperventilation increases oxygenation in pigs.

    Science.gov (United States)

    Roubík, K; Pachl, J; Zábrodský, V

    2011-01-01

    High frequency oscillatory ventilation (HFOV), contrary to conventional ventilation, enables a safe increase in tidal volume (V(T)) without endangering alveoli by volutrauma or barotrauma. The aim of the study is to introduce the concept of normocapnic high frequency oscillatory hyperventilation and to assess its effect upon oxygen gain under experimental conditions. Laboratory pigs (n = 9) were investigated under total intravenous anesthesia in three phases. Phase 1: Initial volume controlled HFOV period. Phase 2: Hyperventilation--V(T) was increased by (46 +/- 12) % when compared to normocapnic V(T) during phase 1. All other ventilatory parameters were unchanged. A significant increase in PaO(2) (by 3.75 +/- 0.52 kPa, p hyperventilation was achieved by an iterative increase in the CO(2) fraction in the inspiratory gas by a CO(2) admixture. All ventilatory parameters were unchanged. A significant increase in PaO(2) (by 3.79 +/- 0.73 kPa, p hyperventilation offers a lung protective strategy that significantly improves oxygenation whilst preserving normocapnia.

  19. Relics in galaxy clusters at high radio frequencies

    Science.gov (United States)

    Kierdorf, M.; Beck, R.; Hoeft, M.; Klein, U.; van Weeren, R. J.; Forman, W. R.; Jones, C.

    2017-04-01

    Aims: We investigated the magnetic properties of radio relics located at the peripheries of galaxy clusters at high radio frequencies, where the emission is expected to be free of Faraday depolarization. The degree of polarization is a measure of the magnetic field compression and, hence, the Mach number. Polarization observations can also be used to confirm relic candidates. Methods: We observed three radio relics in galaxy clusters and one radio relic candidate at 4.85 and 8.35 GHz in total emission and linearly polarized emission with the Effelsberg 100-m telescope. In addition, we observed one radio relic candidate in X-rays with the Chandra telescope. We derived maps of polarization angle, polarization degree, and Faraday rotation measures. Results: The radio spectra of the integrated emission below 8.35 GHz can be well fitted by single power laws for all four relics. The flat spectra (spectral indices of 0.9 and 1.0) for the so-called Sausage relic in cluster CIZA J2242+53 and the so-called Toothbrush relic in cluster 1RXS 06+42 indicate that models describing the origin of relics have to include effects beyond the assumptions of diffuse shock acceleration. The spectra of the radio relics in ZwCl 0008+52 and in Abell 1612 are steep, as expected from weak shocks (Mach number ≈2.4). Polarization observations of radio relics offer a method of measuring the strength and geometry of the shock front. We find polarization degrees of more than 50% in the two prominent Mpc-sized radio relics, the Sausage and the Toothbrush, which are among the highest percentages of linear polarization detected in any extragalactic radio source to date. This is remarkable because the large beam size of the Effelsberg single-dish telescope corresponds to linear extensions of about 300 kpc at 8.35 GHz at the distances of the relics. The high degree of polarization indicates that the magnetic field vectors are almost perfectly aligned along the relic structure, as expected for shock

  20. Measurement of the Low Frequency Noise of MOSFETs under Large Signal RF Excitation

    NARCIS (Netherlands)

    van der Wel, A.P.; Klumperink, Eric A.M.; Nauta, Bram

    A measurement technique [1] is presented that allows measurement of MOSFET low frequency (LF) noise under large signal RF (Radio Frequency) excitation. Measurements indicate that MOSFETS exhibit a reduction in LF noise when they are cycled from inversion to accummulation and that this reduction does

  1. Resent developments in high-frequency surface-wave techniques

    Science.gov (United States)

    Xia, J.; Pan, Y.; Zeng, C.

    2012-12-01

    High-frequency Rayleigh-wave methods, such as Multi-channel Analysis of Surface Waves (MASW), are getting increasingly attention in the near-surface geophysics and geotechnique community in the last 20 years because of their non-invasive, non-destructive, efficient, and low-cost advantages and their success in environmental and engineering applications. They are viewed by near-surface geophysics community as the one of most promise techniques in the future. However, they face unique problems related to extremely irregular velocity variations in near-surface geology or man-made constructions, for example, highway, foundation, dam, levee, jetty, etc., which are not solvable by techniques or algorithms widely used in earthquake seismology or oil/gas seismic exploration. We present solutions to the problems associated with near-surface materials that possess velocity inverse and high Poisson's ratio. Calculation of dispersion curves by existing algorithms may fail for some special velocity models due to velocity inverse (a high-velocity layer on the top of a low-velocity layer). Two velocity models are most common in near-surface applications. One is a low-velocity half space model and the other a high-velocity topmost layer. The former model results in a complex matrix that no roots can be found in the real number domain, which implies that no phase velocities can be calculated in certain frequency ranges based on current exist algorithms. A solution is to use the real part of the root of the complex number. It is well-known that phase velocities approach about 91% of the shear (S)-wave velocity of the topmost layer when wavelengths are much shorter than the thickness of the topmost layer. The later model, however, results in that phase velocities in a high-frequency range calculated using the current algorithms approach a velocity associated with the S-wave velocity of the second layer NOT the topmost layer. A solution to this problem is to use a two-layer model to

  2. Tesla’s high voltage and high frequency generators with oscillatory circuits

    OpenAIRE

    Cvetić Jovan M.

    2016-01-01

    The principles that represent the basics of the work of the high voltage and high frequency generator with oscillating circuits will be discussed. Until 1891, Tesla made and used mechanical generators with a large number of extruded poles for the frequencies up to about 20 kHz. The first electric generators based on a new principle of a weakly coupled oscillatory circuits he used for the wireless signal transmission, for the study of the discharges in vacuu...

  3. Mechanisms and factors that influence high frequency retroviral recombination

    DEFF Research Database (Denmark)

    Delviks-Frankenberry, Krista; Galli, Andrea; Nikolaitchik, Olga

    2011-01-01

    With constantly changing environmental selection pressures, retroviruses rely upon recombination to reassort polymorphisms in their genomes and increase genetic diversity, which improves the chances for the survival of their population. Recombination occurs during DNA synthesis, whereby reverse...... transcriptase undergoes template switching events between the two copackaged RNAs, resulting in a viral recombinant with portions of the genetic information from each parental RNA. This review summarizes our current understanding of the factors and mechanisms influencing retroviral recombination, fidelity...... of the recombination process, and evaluates the subsequent viral diversity and fitness of the progeny recombinant. Specifically, the high mutation rates and high recombination frequencies of HIV-1 will be analyzed for their roles in influencing HIV-1 global diversity, as well as HIV-1 diagnosis, drug treatment...

  4. Frequency selective surfaces based high performance microstrip antenna

    CERN Document Server

    Narayan, Shiv; Jha, Rakesh Mohan

    2016-01-01

    This book focuses on performance enhancement of printed antennas using frequency selective surfaces (FSS) technology. The growing demand of stealth technology in strategic areas requires high-performance low-RCS (radar cross section) antennas. Such requirements may be accomplished by incorporating FSS into the antenna structure either in its ground plane or as the superstrate, due to the filter characteristics of FSS structure. In view of this, a novel approach based on FSS technology is presented in this book to enhance the performance of printed antennas including out-of-band structural RCS reduction. In this endeavor, the EM design of microstrip patch antennas (MPA) loaded with FSS-based (i) high impedance surface (HIS) ground plane, and (ii) the superstrates are discussed in detail. The EM analysis of proposed FSS-based antenna structures have been carried out using transmission line analogy, in combination with the reciprocity theorem. Further, various types of novel FSS structures are considered in desi...

  5. High frequency modulation circuits based on photoconductive wide bandgap switches

    Energy Technology Data Exchange (ETDEWEB)

    Sampayan, Stephen

    2018-02-13

    Methods, systems, and devices for high voltage and/or high frequency modulation. In one aspect, an optoelectronic modulation system includes an array of two or more photoconductive switch units each including a wide bandgap photoconductive material coupled between a first electrode and a second electrode, a light source optically coupled to the WBGP material of each photoconductive switch unit via a light path, in which the light path splits into multiple light paths to optically interface with each WBGP material, such that a time delay of emitted light exists along each subsequent split light path, and in which the WBGP material conducts an electrical signal when a light signal is transmitted to the WBGP material, and an output to transmit the electrical signal conducted by each photoconductive switch unit. The time delay of the photons emitted through the light path is substantially equivalent to the time delay of the electrical signal.

  6. Planck early results. VI. The High Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Colley, J.-M.; Bartlett, J.G.; Bucher, M.

    2011-01-01

    We describe the processing of the 336 billion raw data samples from the High Frequency Instrument (HFI) which we performed to produce six temperature maps from the first 295 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545...... by the HFI Data Processing Centre reach our goals in terms of sensitivity, resolution, and photometric accuracy. They are already sufficiently accurate and well-characterised to allow scientific analyses which are presented in an accompanying series of early papers. At this stage, HFI data appears...... to be of high quality and we expect that with further refinements of the data processing we should be able to achieve, or exceed, the science goals of the Planck project. © ESO, 2011....

  7. A method for extracting respiratory frequency during blood pressure measurement, from oscillometric cuff pressure pulses and Korotkoff sounds recorded during the measurement.

    Science.gov (United States)

    Diliang Chen; Fei Chen; Murray, Alan; Dingchang Zheng

    2016-08-01

    Respiratory frequency is an important physiological feature commonly used to assess health. However, the current measurements involve dedicated devices which not only increase the medical cost but also make health monitoring inconvenient. Earlier studies have shown that respiratory frequency could be extracted from electrocardiography (ECG) signal, but little was done to assess the possibility of extracting respiratory frequency from oscillometric cuff pressure pulses (OscP) or Korotkoff sounds (KorS), which are normally used for measuring blood pressure and more easily accessible than the ECG signal. This study presented a method to extract respiratory frequency from OscP and KorS during clinical blood pressure measurement. The method was evaluated with clinical data collected from 15 healthy participants, and its measurement accuracy was compared with a reference respiratory rate obtained with a magnetometer. Experimental results showed small non-significant mean absolute bias (0.019 Hz for OscP and 0.024 Hz for KorS) and high correlation (0.7 for both OscP and KorS) between the reference respiratory frequency and respiratory frequency extracted from OscP or KorS, indicating the high reliability of extracting respiratory frequency from OscP and KorS during normal blood pressure measurement.

  8. Main meal frequency measures in the Health Behaviour in School-aged Children study

    DEFF Research Database (Denmark)

    Pedersen, Trine Pagh; Holstein, Bjørn E; Laursen, Bjarne

    2015-01-01

    OBJECTIVES: To estimate agreement between questionnaire-based frequency measures from the Health Behaviour in School-aged Children study (HBSC) and 7-day 24-h recall measures of breakfast, lunch and evening meals among 11-15-year-olds, and examine whether disagreement between the two methods varied...... for the breakfast measure: per cent agreement 0.70-0.87, kappa 0.43-0.65. Fair agreement for the lunch measure: per cent agreement 0.53-0.84, kappa 0.26-0.54. High per cent agreement for the evening meal measure (0.83-0.95) but poor kappa agreement (0.14-0.19). Being immigrant predicted disagreement between the two...... methods for week day breakfast OR (95 % CI) 2.17 (1.16-4.04) and lunch 2.44 (1.33-4.48). CONCLUSIONS: We found good to moderate agreement between frequency and 7-day 24-h recall measures for breakfast, a fair agreement for lunch and for evening meal the two agreement methods provided different results...

  9. High-frequency noise characterization of graphene field effect transistors on SiC substrates

    Science.gov (United States)

    Yu, C.; He, Z. Z.; Song, X. B.; Liu, Q. B.; Dun, S. B.; Han, T. T.; Wang, J. J.; Zhou, C. J.; Guo, J. C.; Lv, Y. J.; Cai, S. J.; Feng, Z. H.

    2017-07-01

    Considering its high carrier mobility and high saturation velocity, a low-noise amplifier is thought of as being the most attractive analogue application of graphene field-effect transistors. The noise performance of graphene field-effect transistors at frequencies in the K-band remains unknown. In this work, the noise parameters of a graphene transistor are measured from 10 to 26 GHz and noise models are built with the data. The extrinsic minimum noise figure for a graphene transistor reached 1.5 dB, and the intrinsic minimum noise figure was as low as 0.8 dB at a frequency of 10 GHz, which were comparable with the results from tests on Si CMOS and started to approach those for GaAs and InP transistors. Considering the short development time, the current results are a significant step forward for graphene transistors and show their application potential in high-frequency electronics.

  10. Research on controlling middle spatial frequency error of high gradient precise aspheric by pitch tool

    Science.gov (United States)

    Wang, Jia; Hou, Xi; Wan, Yongjian; Shi, Chunyan; Zhong, Xianyun

    2016-09-01

    Extreme optical fabrication projects known as EUV and X-ray optic systems, which are representative of today's advanced optical manufacturing technology level, have special requirements for the optical surface quality. In synchroton radiation (SR) beamlines, mirrors of high shape accuracy is always used in grazing incidence. In nanolithograph systems, middle spatial frequency errors always lead to small-angle scattering or flare that reduces the contrast of the image. The slope error is defined for a given horizontal length, the increase or decrease in form error at the end point relative to the starting point is measured. The quality of reflective optical elements can be described by their deviation from ideal shape at different spatial frequencies. Usually one distinguishes between the figure error, the low spatial error part ranging from aperture length to 1mm frequencies, and the mid-high spatial error part from 1mm to 1 μm and from1 μm to some 10 nm spatial frequencies, respectively. Firstly, this paper will disscuss the relationship between slope error and middle spatial frequency error, which both describe the optical surface error along with the form profile. Then, experimental researches will be conducted on a high gradient precise aspheric with pitch tool, which aim to restraining the middle spatial frequency error.

  11. Indoor measurements of sound at low frequencies

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2006-01-01

    a room average. As a means in this, current Swedish and Danish measurement methods include corner measurements. These positions are however still with some specified height and distance to the walls, and they may not effectively serve the purpose. Alternative measurement positions were investigated based...... positions specified by Swedish and Danish measurement methods, and 3) all three-dimensional corners. The level that is exceeded in 10% of the space in a room (L90%) was found to be a reasonable target for a measurement method rather than the absolute maximum. Good results can be expected with the Swedish...... method, as the Swedish corner position is obtained by scanning and yields levels close to the target; however there are serious concerns regarding the use of C-weighting in the scanning. With the Danish method, good results can only be expected, if complainants can accurately appoint measurement...

  12. Very high frequency plasma reactant for atomic layer deposition

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Il-Kwon; Yoo, Gilsang; Yoon, Chang Mo [School of Electrical and Electronic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Kim, Tae Hyung; Yeom, Geun Young [Department of Advanced Materials Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Kim, Kangsik; Lee, Zonghoon [School Materials Science and Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919 (Korea, Republic of); Jung, Hanearl; Lee, Chang Wan [School of Electrical and Electronic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Kim, Hyungjun, E-mail: hyungjun@yonsei.ac.kr [School of Electrical and Electronic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Lee, Han-Bo-Ram, E-mail: hbrlee@inu.ac.kr [Department of Materials Science and Engineering, Incheon National University, 406-840 Incheon (Korea, Republic of)

    2016-11-30

    Highlights: • Fundamental research plasma process for thin film deposition is presented. • VHF plasma source for PE-ALD Al{sub 2}O{sub 3} was employed to reduce plasma damage. • The use of VHF plasma improved all of the film qualities and growth characteristics. - Abstract: Although plasma-enhanced atomic layer deposition (PE-ALD) results in several benefits in the formation of high-k dielectrics, including a low processing temperature and improved film properties compared to conventional thermal ALD, energetic radicals and ions in the plasma cause damage to layer stacks, leading to the deterioration of electrical properties. In this study, the growth characteristics and film properties of PE-ALD Al{sub 2}O{sub 3} were investigated using a very-high-frequency (VHF) plasma reactant. Because VHF plasma features a lower electron temperature and higher plasma density than conventional radio frequency (RF) plasma, it has a larger number of less energetic reaction species, such as radicals and ions. VHF PE-ALD Al{sub 2}O{sub 3} shows superior physical and electrical properties over RF PE-ALD Al{sub 2}O{sub 3}, including high growth per cycle, excellent conformality, low roughness, high dielectric constant, low leakage current, and low interface trap density. In addition, interlayer-free Al{sub 2}O{sub 3} on Si was achieved in VHF PE-ALD via a significant reduction in plasma damage. VHF PE-ALD will be an essential process to realize nanoscale devices that require precise control of interfaces and electrical properties.

  13. Modeling of High-Frequency Electromagnetic Effects on an Ironless Inductive Position Sensor

    CERN Document Server

    Danisi, Alessandro; Masi, Alessandro; Perriard, Yves

    2013-01-01

    The ironless inductive position sensor (I2PS) is a five-coil air-cored structure that senses the variation of flux linkage between supply and sense coils and relates it to the linear position of a moving coil. In air-cored structures, the skin and proximity effect can bring substantial variations of the electrical resistance, leading to important deviations from the low-frequency functioning. In this paper, an analysis of the effect of high-frequency phenomena on the I2PS functioning is described. The key-element is the modeling of the resistance as a function of the frequency, which starts from the analytical resolution of Maxwell's equations in the coil's geometry. The analysis is validated by means of experimental measurements on custom sensor coils. The resulting model is integrated with the existing low-frequency analysis and represents a complete tool for the design of an I2PS sensor, framing its electromagnetic behavior.

  14. Apparatus and method for qualitative and quantitative measurements of optical properties of turbid media using frequency-domain photon migration

    Science.gov (United States)

    Tromberg, Bruce J.; Tsay, Tsong T.; Berns, Michael W.; Svaasand, Lara O.; Haskell, Richard C.

    1995-01-01

    Optical measurements of turbid media, that is media characterized by multiple light scattering, is provided through an apparatus and method for exposing a sample to a modulated laser beam. The light beam is modulated at a fundamental frequency and at a plurality of integer harmonics thereof. Modulated light is returned from the sample and preferentially detected at cross frequencies at frequencies slightly higher than the fundamental frequency and at integer harmonics of the same. The received radiance at the beat or cross frequencies is compared against a reference signal to provide a measure of the phase lag of the radiance and modulation ratio relative to a reference beam. The phase and modulation amplitude are then provided as a frequency spectrum by an array processor to which a computer applies a complete curve fit in the case of highly scattering samples or a linear curve fit below a predetermined frequency in the case of highly absorptive samples. The curve fit in any case is determined by the absorption and scattering coefficients together with a concentration of the active substance in the sample. Therefore, the curve fitting to the frequency spectrum can be used both for qualitative and quantitative analysis of substances in the sample even though the sample is highly turbid.

  15. Conceptual design of an apparatus for measuring frequency-dependent streaming potential of porous media

    Science.gov (United States)

    Tardif, Eric; Walker, Emilie; Glover, Paul; Ruel, Jean

    2010-05-01

    Electro-kinetic phenomena link fluid flow and electrical flow in porous and fractured media such that a hydraulic flow will generate an electrical current and vice versa. Such a link is likely to be extremely useful, especially in the development of the theory of the electro-seismic method. However, surprisingly little experimental determination, numerical modeling and theoretical development have taken place, and what exists is for steady state flow. There have been only a few attempts at making experimental determinations of the frequency-dependent streaming potential coupling coefficient because of their difficulty, and only one rare measurement made on rocks. Here we have considered six different approaches to making laboratory determinations of the frequency-dependent streaming potential coupling coefficient. In each case, we have quantified the practical difficulties involved in each method. We conclude that the electro-magnetic drive and the piezo-electric are the only approaches that are practicable with current technology. We have also constructed a simplified trial apparatus using the electro-magnetic drive to test the conceptual design with samples in the form of sands and beads. Tests with this apparatus on Ottawa sandstone and glass bead packs have shown that high quality measurements of the frequency-dependent streaming potential coupling coefficient can be made, and we are currently extending its frequency range. Tests have indicated that it is important to ascertain whether the measured frequency-dependent streaming potential coupling coefficient is independent of the volume of fluid passing through the sample per cycle. We have used our experience with the trial apparatus to design a new apparatus for a 1 cm diameter sample, and with the help of an engineering approach we have determined the range of possible sample permeabilities for samples between 0.5 and 2 cm in length. The new cell will have a maximum confining pressure of compressed nitrogen

  16. Dual-Frequency Doppler-Lidar Method of Wind Measurement.

    Science.gov (United States)

    1980-01-22

    Entered) REPORT DOCUMENTATION PAGE READ INSTRUCTIONS BEFORE COMPLETING PORN I. REPORT NUMBER z. .OVT ACCESSION NO. 3. RECIPIENT*S CATALOG NUMBER 1 14...anemometer, Weather- Measure Model W1738, was positioned with the hub about 20 cm from the center of the probed volume. It was aligned to measure the same

  17. Filter-based ultralow-frequency Raman measurement down to 2 cm-1 for fast Brillouin spectroscopy measurement

    Science.gov (United States)

    Liu, Xue-Lu; Liu, He-Nan; Wu, Jiang-Bin; Wu, Han-Xu; Zhang, Tao; Zhao, Wei-Qian; Tan, Ping-Heng

    2017-05-01

    Simultaneous Stokes and anti-Stokes ultralow-frequency (ULF) Raman measurement down to ˜2 cm-1 or 60 GHz is realized by a single-stage spectrometer in combination with volume-Bragg-grating-based notch filters. This system reveals its excellent performance by probing Brillouin signal of acoustic phonons in silicon, germanium, gallium arsenide, and gallium nitride. The deduced sound velocity and elastic constants are in good accordance with previous results determined by various methods. This system can shorten the integration time of the Brillouin signal with a good signal-to-noise ratio by more than 2000-fold compared to a Fabry-Perot interferometer (FPI). This study shows how a filter-based ULF Raman system can be used to reliably achieve Brillouin spectroscopy for condensed materials with high sensitivity and high signal-to-noise ratio, stimulating fast Brillouin spectrum measurements to probe acoustic phonons in semiconductors.

  18. Measurement of high-power microwave pulse under intense ...

    Indian Academy of Sciences (India)

    KALI-1000 pulse power system has been used to generate single pulse nanosecond duration high-power microwaves (HPM) from a virtual cathode oscillator (VIRCATOR) device. HPM power measurements were carried out using a transmitting–receiving system in the presence of intense high frequency (a few MHz) ...

  19. Tecnologia radio cognitiva en la banda ultra high frequency (UHF

    Directory of Open Access Journals (Sweden)

    Hernán Paz Penagos

    2014-01-01

    Full Text Available Mobile cellular communication companies in Colombia require more spectrum resources to expand their portfolio of services. However, additional frequency bands for that particular purpose are scarce, yet it is well known that there are many underutilized licensed bands. Therefore new radio technologies are being studied in order to solve this problem, e.g. Software Defined Radio SDR Cognitive Radio CR and Dynamic Spectrum Access DSA. These strategies recommend mobility across the radio spectrum to meet various needs and achieve greater efficiency when managing such a scarce resource. In this context, a case study is presented in an attempt to examine the require¬ments that must be met for the implementation of cognitive radio networks in Bogota. The case study includes evaluation for the possibility of migration from cellular communications to cognitive radio since the bands assigned to UltraHigh Frequency UHF television offer possible free-of-interference coexistence between the two services (i.e. Cellular and TV. The study shows feasibility to migration; however, the implementations of cognitive radio need availability of hardware, software and flexible radio platforms.

  20. Refractivity variations and propagation at Ultra High Frequency

    Science.gov (United States)

    Alam, I.; Najam-Ul-Islam, M.; Mujahid, U.; Shah, S. A. A.; Ul Haq, Rizwan

    Present framework is established to deal with the refractivity variations normally affected the radio waves propagation at different frequencies, ranges and different environments. To deal such kind of effects, many researchers proposed several methodologies. One method is to use the parameters from meteorology to investigate these effects of variations in refractivity on propagation. These variations are region specific and we have selected a region of one kilometer height over the English Channel. We have constructed different modified refractivity profiles based on the local meteorological data. We have recorded more than 48 million received signal strength from a communication links of 50 km operating at 2015 MHz in the Ultra High Frequency band giving path loss between transmitting and receiving stations of the experimental setup. We have used parabolic wave equation method to simulate an hourly value of signal strength and compared the obtained simulated loss to the experimental loss. The analysis is made to compute refractivity distribution of standard (STD) and ITU (International Telecommunication Union) refractivity profiles for various evaporation ducts. It is found that a standard refractivity profile is better than the ITU refractivity profiles for the region at 2015 MHz. Further, it is inferred from the analysis of results that 10 m evaporation duct height is the dominant among all evaporation duct heights considered in the research.

  1. Non-invasive high-frequency vascular ultrasound elastography

    Energy Technology Data Exchange (ETDEWEB)

    Maurice, Roch L [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital, Quebec (Canada); Daronat, Michel [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital, Quebec (Canada); Ohayon, Jacques [Laboratory TIMC-IMAG, UMR CNRS 5525, Institut A. Bonniot, 38706 La Tronche (France); Stoyanova, Ekatherina [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital, Quebec (Canada); Foster, F Stuart [Department of Medical Biophysics, Sunnybrook and Women' s College Health Sciences Centre, University of Toronto, Ontario (Canada); Cloutier, Guy [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital, Quebec (Canada); Department of Radiology, Radio-oncology and Nuclear Medicine, University of Montreal, Quebec (Canada)

    2005-04-07

    Non-invasive vascular elastography (NIVE) was recently introduced to characterize mechanical properties of superficial arteries. In this paper, the feasibility of NIVE and its applicability in the context of high-frequency ultrasound imaging is investigated. First, experiments were performed in vitro on vessel-mimicking phantoms. Polyvinyl alcohol cryogel was used to create two double-layer vessels with different mechanical properties. In both cases, the stiffness of the inner layer was made softer. Radial stress was applied within the lumen of the phantoms by applying incremental static pressure steps with a column of a flowing mixture of water-glycerol. The vessel phantoms were insonified at 32 MHz with an ultrasound biomicroscope to provide cross-section sequences of radio-frequency (RF) ultrasound data. The Lagrangian speckle model estimator (LSME) was used to assess the two-dimensional-strain tensors, and the composite Von Mises elastograms were computed. A new implementation of the LSME based on the optical flow equations was introduced. Deformation parameters were estimated using an inversion algorithm. For each in vitro experiment, both layers of approximately 1 mm were distinguished. Second, the use of the method for the purpose of studying small vessels (MicroNIVE) in genetically engineered rodents was introduced. Longitudinal scans of the carotid artery were performed at 40 MHz. The in vivo results give confidence in the feasibility of MicroNIVE as a potential tool to non-invasively study the impact of targeted genes on vascular remodelling in rodents.

  2. The Solar Probe Plus Radio Frequency Spectrometer: Measurement requirements, analog design, and digital signal processing

    Science.gov (United States)

    Pulupa, M.; Bale, S. D.; Bonnell, J. W.; Bowen, T. A.; Carruth, N.; Goetz, K.; Gordon, D.; Harvey, P. R.; Maksimovic, M.; Martínez-Oliveros, J. C.; Moncuquet, M.; Saint-Hilaire, P.; Seitz, D.; Sundkvist, D.

    2017-03-01

    The Radio Frequency Spectrometer (RFS) is a two-channel digital receiver and spectrometer, which will make remote sensing observations of radio waves and in situ measurements of electrostatic and electromagnetic fluctuations in the solar wind. A part of the FIELDS suite for Solar Probe Plus (SPP), the RFS is optimized for measurements in the inner heliosphere, where solar radio bursts are more intense and the plasma frequency is higher compared to previous measurements at distances of 1 AU or greater. The inputs to the RFS receiver are the four electric antennas mounted near the front of the SPP spacecraft and a single axis of the SPP search coil magnetometer (SCM). Each RFS channel selects a monopole or dipole antenna input, or the SCM input, via multiplexers. The primary data products from the RFS are autospectra and cross spectra from the selected inputs. The spectra are calculated using a polyphase filter bank, which enables the measurement of low amplitude signals of interest in the presence of high-amplitude narrowband noise generated by spacecraft systems. We discuss the science signals of interest driving the RFS measurement objectives, describe the RFS analog design and digital signal processing, and show examples of current performance.

  3. Measurements of Low Frequency Noise of Infrared Photo-Detectors with Transimpedance Detection System

    Directory of Open Access Journals (Sweden)

    Ciura Łukasz

    2014-08-01

    Full Text Available The paper presents the method and results of low-frequency noise measurements of modern mid-wavelength infrared photodetectors. A type-II InAs/GaSb superlattice based detector with nBn barrier architecture is compared with a high operating temperature (HOT heterojunction HgCdTe detector. All experiments were made in the range 1 Hz - 10 kHz at various temperatures by using a transimpedance detection system, which is examined in detail. The power spectral density of the nBn’s dark current noise includes Lorentzians with different time constants while the HgCdTe photodiode has more uniform 1/f - shaped spectra. For small bias, the low-frequency noise power spectra of both devices were found to scale linearly with bias voltage squared and were connected with the fluctuations of the leakage resistance. Leakage resistance noise defines the lower noise limit of a photodetector. Other dark current components give raise to the increase of low-frequency noise above this limit. For the same voltage biasing devices, the absolute noise power densities at 1 Hz in nBn are 1 to 2 orders of magnitude lower than in a MCT HgCdTe detector. In spite of this, low-frequency performance of the HgCdTe detector at ~ 230K is still better than that of InAs/GaSb superlattice nBn detector.

  4. Propagation Impact on Modern HF (High Frequency) Communications System Design

    Science.gov (United States)

    1986-03-01

    terminal to choose the best frequency. These efforts were aborted in the early 1970s with the expectation of satellite systems. Furthermore, concern...traditional diffic communications and including selectiv connectivity. The frequency selectio ionospheric predic of channel interfe an

  5. Laser generated ultrasound sources using polymer nanocomposites for high frequency metrology

    KAUST Repository

    Rajagopal, Srinath

    2017-11-22

    Accurate characterization of ultrasound fields generated by diagnostic and therapeutic transducers is critical for patient safety. This requires hydrophones calibrated to a traceable standard and currently the upper calibration frequency range available to the user community is limited to a frequency of 40 MHz. However, the increasing use of high frequencies for both imaging and therapy necessitates calibrations to frequencies well beyond this range. For this to be possible, a source of high amplitude, broadband, quasi-planar and stable ultrasound fields is required. This is difficult to achieve using conventional piezoelectric sources, but laser generated ultrasound is a promising technique in this regard. In this study, various polymer-carbon nanotube nanocomposites (PNC) were fabricated and tested for their suitability for such an application by varying the polymer type, carbon nanotubes weight content in the polymer, and PNC thickness. A broadband hydrophone was used to measure the peak pressure and bandwidth of the laser generated ultrasound pulse. Peak-positive pressures of up to 8 MPa and −6dB bandwidths of up to 40 MHz were recorded. There is a nonlinear dependence of the peak pressure on the laser fluence and the bandwidth scales inversely proportionally to the peak pressure. The high-pressure plane waves generated from this preliminary investigation has demonstrated that laser generated ultrasound sources are a promising technique for high frequency calibration of hydrophones.

  6. Theory and measurement of the soliton self-frequency shift and efficiency in optical microcavities.

    Science.gov (United States)

    Yi, Xu; Yang, Qi-Fan; Yang, Ki Youl; Vahala, Kerry

    2016-08-01

    Dissipative Kerr cavity solitons experience a so-called self-frequency shift (SFS) as a result of Raman interactions. The frequency shift has been observed in several microcavity systems. The Raman process has also been shown numerically to influence the soliton pumping efficiency. Here, a perturbed Lagrangian approach is used to derive simple analytical expressions for the SFS and the soliton efficiency. The predicted dependences of these quantities on soliton pulse width are compared with measurements in a high-Q silica microcavity. The Raman time constant in silica is also inferred. Analytical expressions for the Raman SFS and soliton efficiency greatly simplify the prediction of soliton behavior over a wide range of microcavity platforms.

  7. Tesla’s high voltage and high frequency generators with oscillatory circuits

    Directory of Open Access Journals (Sweden)

    Cvetić Jovan M.

    2016-01-01

    Full Text Available The principles that represent the basics of the work of the high voltage and high frequency generator with oscillating circuits will be discussed. Until 1891, Tesla made and used mechanical generators with a large number of extruded poles for the frequencies up to about 20 kHz. The first electric generators based on a new principle of a weakly coupled oscillatory circuits he used for the wireless signal transmission, for the study of the discharges in vacuum tubes, the wireless energy transmission, for the production of the cathode rays, that is x-rays and other experiments. Aiming to transfer the signals and the energy to any point of the surface of the Earth, in the late of 19th century, he had discovered and later patented a new type of high frequency generator called a magnifying transmitter. He used it to examine the propagation of electromagnetic waves over the surface of the Earth in experiments in Colorado Springs in the period 1899-1900. Tesla observed the formation of standing electromagnetic waves on the surface of the Earth by measuring radiated electric field from distant lightning thunderstorm. He got the idea to generate the similar radiation to produce the standing waves. On the one hand, signal transmission, i.e. communication at great distances would be possible and on the other hand, with more powerful and with at least three magnifying transmitters the wireless transmission of energy without conductors at any point of the Earth surface could also be achieved. The discovery of the standing waves on the surface of the Earth and the invention of the magnifying transmitter he claimed his greatest inventions. Less than two years later, at the end of 1901, he designed and started to build a much stronger magnifying transmitter on Long Island near New York City (the Wardenclyffe tower wishing to become a world telecommunication center. During the tower construction, he elaborated the plans for an even stronger transmitter based on

  8. Structural Health Monitoring Using High-Frequency Electromechanical Impedance Signatures

    Directory of Open Access Journals (Sweden)

    Wei Yan

    2010-01-01

    Full Text Available An overview of recent advances in electromechanical impedance- (EMI- based structural health monitoring is presented in this paper. The basic principle of the EMI method is to use high-frequency excitation to sense the local area of a structure. Changes in impedance indicate changes in the structure, which in turn indicate that damages appear. An accurate EMI model based on the method of reverberation-ray matrix is introduced to correlate changes in the signatures to physical parameters of structures for damage detection. Comparison with other numerical results and experimental data validates the present model. A brief remark of the feasibility of implementing the EMI method is considered and the effects of some physical parameters on EMI technique are also discussed.

  9. Ultra-high Frequency Linear Fiber Optic Systems

    CERN Document Server

    Lau, Kam

    2011-01-01

    This book provides an in-depth treatment of both linear fiber-optic systems and their key enabling devices. It presents a concise but rigorous treatment of the theory and practice of analog (linear) fiber-optics links and systems that constitute the foundation of Hybrid Fiber Coax infrastructure in present-day CATV distribution and cable modem Internet access. Emerging applications in remote fiber-optic feed for free-space millimeter wave enterprise campus networks are also described. Issues such as dispersion and interferometric noise are treated quantitatively, and means for mitigating them are explained. This broad but concise text will thus be invaluable not only to students of fiber-optics communication but also to practicing engineers. To the second edition of this book important new aspects of linear fiber-optic transmission technologies are added, such as high level system architectural issues, algorithms for deriving the optimal frequency assignment, directly modulated or externally modulated laser t...

  10. High frequency ultrasound evaluation of traumatic peripheral nerve injuries.

    Science.gov (United States)

    Hollister, Anne M; Simoncini, Alberto; Sciuk, Adam; Jordan, Jenee'

    2012-01-01

    Accurate diagnosis and localization of peripheral nerve traumatic injury remains difficult. Early diagnosis and repair of nerve discontinuity lesions lead to better outcome than delayed repair. We used new high frequency ultrasound to evaluate 24 patients with 29 traumatic nerve injuries. There were a variety of causes including gunshot wounds, blunt injuries, burns, stabbings, and motor vehicle accidents. The patients were then either treated surgically with nerve status directly observed or followed clinically for recovery of nerve function. The ultrasound findings correspond with the clinical outcome of 28 of the 29 nerves. While this is a study limited by a small patient number, ultrasound evaluation should be considered in the evaluation of nerve injury and can lead to early diagnosis and treatment of surgical nerve injuries.

  11. Dynamical structures of high-frequency financial data

    Science.gov (United States)

    Kim, Kyungsik; Yoon, Seong-Min; Kim, SooYong; Chang, Ki-Ho; Kim, Yup; Hoon Kang, Sang

    2007-03-01

    We study the dynamical behavior of high-frequency data from the Korean Stock Price Index (KOSPI) using the movement of returns in Korean financial markets. The dynamical behavior of a binarized series of our models is not completely random. In addition, the conditional probability is numerically estimated from a return series of KOSPI tick data. Non-trivial probability structures can be constituted from binary time series of autoregressive (AR), logit, and probit models, for which the Akaike Information Criterion shows a minimum value at the 15th order. From our results, we find that the value of the correct match ratio for the AR model is slightly larger than that derived by other models.

  12. High-Performance Control in Radio Frequency Power Amplification Systems

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Kofod

    This thesis presents a broad study of methods for increasing the efficiency of narrow-band radio transmitters. The study is centered around the base station application and TETRA/TEDS networks. The general solution space studied is that of envelope tracking applied to linear class-A/B radio...... frequency power amplifiers (RFPAs) in conjunction with cartesian feedback (CFB) used to linearize the overall transmitter system. On a system level, it is demonstrated how envelope tracking is particularly useful for RF carriers with high peak-to-average power ratios, such as TEDS with 10dB. It is also...... and ripple voltage. It is found that the simple fourth-order filter buck converter is ideal for TETRA and TEDS envelope tracking power supplies. The problem of extracting maximum control bandwidth from a given power topology is given particular attention, with a range of, arguably new, insights resulting...

  13. Low-frequency versus high-frequency synchronisation in chirp-evoked auditory brainstem responses

    DEFF Research Database (Denmark)

    Rønne, Filip Munch; Gøtsche-Rasmussen, Kristian

    2011-01-01

    This study investigates the frequency specific contribution to the auditory brainstem response (ABR) of chirp stimuli. Frequency rising chirps were designed to compensate for the cochlear traveling wave delay, and lead to larger wave-V amplitudes than for click stimuli as more auditory nerve fibres...

  14. Low and High-Frequency Field Potentials of Cortical Networks ...

    Science.gov (United States)

    Neural networks grown on microelectrode arrays (MEAs) have become an important, high content in vitro assay for assessing neuronal function. MEA experiments typically examine high- frequency (HF) (>200 Hz) spikes, and bursts which can be used to discriminate between different pharmacological agents/chemicals. However, normal brain activity is additionally composed of integrated low-frequency (0.5-100 Hz) field potentials (LFPs) which are filtered out of MEA recordings. The objective of this study was to characterize the relationship between HF and LFP neural network signals, and to assess the relative sensitivity of LFPs to selected neurotoxicants. Rat primary cortical cultures were grown on glass, single-well MEA chips. Spontaneous activity was sampled at 25 kHz and recorded (5 min) (Multi-Channel Systems) from mature networks (14 days in vitro). HF (spike, mean firing rate, MFR) and LF (power spectrum, amplitude) components were extracted from each network and served as its baseline (BL). Next, each chip was treated with either 1) a positive control, bicuculline (BIC, 25μM) or domoic acid (DA, 0.3μM), 2) or a negative control, acetaminophen (ACE, 100μM) or glyphosate (GLY, 100μM), 3) a solvent control (H2O or DMSO:EtOH), or 4) a neurotoxicant, (carbaryl, CAR 5, 30μM ; lindane, LIN 1, 10μM; permethrin, PERM 25, 50μM; triadimefon, TRI 5, 65μM). Post treatment, 5 mins of spontaneous activity was recorded and analyzed. As expected posit

  15. Atomic fountain clock with very high frequency stability employing a pulse-tube-cryocooled sapphire oscillator.

    Science.gov (United States)

    Takamizawa, Akifumi; Yanagimachi, Shinya; Tanabe, Takehiko; Hagimoto, Ken; Hirano, Iku; Watabe, Ken-ichi; Ikegami, Takeshi; Hartnett, John G

    2014-09-01

    The frequency stability of an atomic fountain clock was significantly improved by employing an ultra-stable local oscillator and increasing the number of atoms detected after the Ramsey interrogation, resulting in a measured Allan deviation of 8.3 × 10(-14)τ(-1/2)). A cryogenic sapphire oscillator using an ultra-low-vibration pulse-tube cryocooler and cryostat, without the need for refilling with liquid helium, was applied as a local oscillator and a frequency reference. High atom number was achieved by the high power of the cooling laser beams and optical pumping to the Zeeman sublevel m(F) = 0 employed for a frequency measurement, although vapor-loaded optical molasses with the simple (001) configuration was used for the atomic fountain clock. The resulting stability is not limited by the Dick effect as it is when a BVA quartz oscillator is used as the local oscillator. The stability reached the quantum projection noise limit to within 11%. Using a combination of a cryocooled sapphire oscillator and techniques to enhance the atom number, the frequency stability of any atomic fountain clock, already established as primary frequency standard, may be improved without opening its vacuum chamber.

  16. Synchronization of vortex formation frequency with the body motion frequency at high Reynolds numbers

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Luiz Antonio Alcantara [Federal University of Itajuba (UNIFEI), MG (Brazil). Inst. of Mechanical Engineering], E-mail: luizantp@unifei.edu.br; Hirata, Miguel Hiroo [State University of Rio de Janeiro (FAT/UERJ), Resende, RJ (Brazil). Fac. de Tecnologia], E-mail: hirata@fat.uerj.br

    2010-07-01

    Understanding vortex induced vibrations is of great importance in the design of a variety of offshore engineering structures, nuclear plant components and cylindrical elements in tube-bank heat exchangers, for example. If a body is placed in a flow, it experiences alternating lift and drag forces caused by the asymmetric formation of vortices, which can cause a structure to vibrate. One of the most interesting features of this flow is the phenomenon of lock-in which is observed when the vortex shedding frequency is close to the body oscillation frequency. This paper presents the results of numerical experiments on vortex shedding from a circular cylinder vibrating in-line or transversely with an incident uniform flow at Reynolds number of 1.0 x 10{sup 5}. The frequencies of the lift and drag coefficients are compared with the body motion frequency when the frequency ratio is about unity. (author)

  17. Measuring ultrashort pulses using frequency-resolved optical gating

    Energy Technology Data Exchange (ETDEWEB)

    Trebino, R. [Sandia National Laboratories, Livermore, CA (United States)

    1993-12-01

    The purpose of this program is the development of techniques for the measurement of ultrafast events important in gas-phase combustion chemistry. Specifically, goals of this program include the development of fundamental concepts and spectroscopic techniques that will augment the information currently available with ultrafast laser techniques. Of equal importance is the development of technology for ultrafast spectroscopy. For example, methods for the production and measurement of ultrashort pulses at wavelengths important for these studies is an important goal. Because the specific vibrational motion excited in a molecule depends sensitively on the intensity, I(t), and the phase, {psi}(t), of the ultrashort pulse used to excite the motion, it is critical to measure both of these quantities for an individual pulse. Unfortunately, this has remained an unsolved problem for many years. Fortunately, this year, the authors present a technique that achieves this goal.

  18. Quasi-B-mode generated by high-frequency gravitational waves and corresponding perturbative photon fluxes

    Energy Technology Data Exchange (ETDEWEB)

    Li, Fangyu, E-mail: cqufangyuli@hotmail.com [Institute of Gravitational Physics, Department of Physics, Chongqing University, Chongqing 400044 (China); Wen, Hao [Institute of Gravitational Physics, Department of Physics, Chongqing University, Chongqing 400044 (China); State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China); Fang, Zhenyun [Institute of Gravitational Physics, Department of Physics, Chongqing University, Chongqing 400044 (China); Wei, Lianfu; Wang, Yiwen; Zhang, Miao [Quantum Optoelectronics Laboratory, Southwest Jiaotong University, Chengdu 610031 (China)

    2016-10-15

    Interaction of very low-frequency primordial (relic) gravitational waves (GWs) to cosmic microwave background (CMB) can generate B-mode polarization. Here, for the first time we point out that the electromagnetic (EM) response to high-frequency GWs (HFGWs) would produce quasi-B-mode distribution of the perturbative photon fluxes. We study the duality and high complementarity between such two B-modes, and it is shown that such two effects are from the same physical origin: the tensor perturbation of the GWs and not the density perturbation. Based on this quasi-B-mode in HFGWs and related numerical calculation, it is shown that the distinguishing and observing of HFGWs from the braneworld would be quite possible due to their large amplitude, higher frequency and very different physical behaviors between the perturbative photon fluxes and background photons, and the measurement of relic HFGWs may also be possible though face to enormous challenge.

  19. Quasi-B-mode generated by high-frequency gravitational waves and corresponding perturbative photon fluxes

    Directory of Open Access Journals (Sweden)

    F.Y. Fangyu Li

    2016-10-01

    Full Text Available Interaction of very low-frequency primordial (relic gravitational waves (GWs to cosmic microwave background (CMB can generate B-mode polarization. Here, for the first time we point out that the electromagnetic (EM response to high-frequency GWs (HFGWs would produce quasi-B-mode distribution of the perturbative photon fluxes. We study the duality and high complementarity between such two B-modes, and it is shown that such two effects are from the same physical origin: the tensor perturbation of the GWs and not the density perturbation. Based on this quasi-B-mode in HFGWs and related numerical calculation, it is shown that the distinguishing and observing of HFGWs from the braneworld would be quite possible due to their large amplitude, higher frequency and very different physical behaviors between the perturbative photon fluxes and background photons, and the measurement of relic HFGWs may also be possible though face to enormous challenge.

  20. Laser generated ultrasound sources using polymer nanocomposites for high frequency metrology

    KAUST Repository

    Rajagopal, Srinath

    2017-11-22

    Accurate characterisation of ultrasound fields generated by diagnostic and therapeutic transducers is critical for patient safety. This requires hydrophones calibrated to a traceable standard. The existing implementation of the primary standard at the National Measurement Institutes, e.g., NPL and PTB, can provide accurate calibration to a maximum frequency of 40MHz. However, the increasing use of high frequencies for both imaging and therapy necessitates calibrations to frequencies well beyond this range. For this to be possible, a source of high amplitude, broadband, quasi-planar and stable ultrasound fields is required. This is difficult to achieve using conventional piezoelectric sources, but laser generated ultrasound is a promising technique in this regard. In this study various polymer-carbon nanotube nanocomposites (PNC) were fabricated and tested for their suitability for such an application.