WorldWideScience

Sample records for high dose pelvic

  1. Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Adkison, Jarrod B.; McHaffie, Derek R.; Bentzen, Soren M.; Patel, Rakesh R.; Khuntia, Deepak [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Petereit, Daniel G. [Department of Radiation Oncology, John T. Vucurevich Regional Cancer Care Institute, Rapid City Regional Hospital, Rapid City, SD (United States); Hong, Theodore S.; Tome, Wolfgang [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Ritter, Mark A., E-mail: ritter@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States)

    2012-01-01

    Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose

  2. Split-Course, High-Dose Palliative Pelvic Radiotherapy for Locally Progressive Hormone-Refractory Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gogna, Nirdosh Kumar, E-mail: kumar_gogna@health.qld.gov.au [Radiation Oncology Services, Mater Centre, Brisbane, Queensland (Australia); Baxi, Siddhartha; Hickey, Brigid; Baumann, Kathryn [Radiation Oncology Services, Mater Centre, Brisbane, Queensland (Australia); Burmeister, Elizabeth [Princess Alexandra Hospital, Brisbane, Queensland (Australia); Holt, Tanya [Radiation Oncology Services, Mater Centre, Brisbane, Queensland (Australia)

    2012-06-01

    Purpose: Local progression, in patients with hormone-refractory prostate cancer, often causes significant morbidity. Pelvic radiotherapy (RT) provides effective palliation in this setting, with most published studies supporting the use of high-dose regimens. The aim of the present study was to examine the role of split-course hypofractionated RT used at our institution in treating this group of patients. Methods and Materials: A total of 34 men with locoregionally progressive hormone-refractory prostate cancer, treated with a split course of pelvic RT (45-60 Gy in 18-24 fractions) between 2000 and 2008 were analyzed. The primary endpoints were the response rate and actuarial locoregional progression-free survival. Secondary endpoints included overall survival, compliance, and acute and late toxicity. Results: The median age was 71 years (range, 53-88). Treatment resulted in an overall initial response rate of 91%, a median locoregional progression-free survival of 43 months, and median overall survival of 28 months. Compliance was excellent and no significant late toxicity was reported. Conclusions: The split course pelvic RT described has an acceptable toxicity profile, is effective, and compares well with other high-dose palliative regimens that have been previously reported.

  3. Transverse colon conduit urinary diversion in patients treated with very high dose pelvic irradiation

    International Nuclear Information System (INIS)

    Ravi, R.; Dewan, A.K.; Pandey, K.K.

    1994-01-01

    Urinary diversion may be required in patients receiving pelvic irradiation for gynaecological or genitourinary cancers either as part of a planned or salvage surgical procedure or for urological complications of irradiation. Records were reviewed for 30 such patients who underwent transverse colon conduit as a primary form of urinary diversion. Most of the conduits were constructed using refluxing ureterocolic anastomoses with stents. The results showed no operative mortality. Although the procedure was associated with a complication rate of 37% and a re-operation rate of 20%, there were no bowel or urinary anastomotic leaks. The operation could be safely performed on patients with renal failure, with 83% of such patients showing normal or improved serum creatinine levels post operatively. The advantages of transverse colon conduit urinary diversion are the use of non-irradiated bowel and ureters for diversion. It is recommended as a primary form of urinary diversion in these high risk cases. (Author)

  4. Complications from high-dose para-aortic and pelvic irradiation for malignant genitourinary tumors

    International Nuclear Information System (INIS)

    Komaki, R.; Barber-Derus, S.; Glisch, C.; Lawton, C.A.; Cox, J.D.; Wilson, J.F.

    1986-01-01

    Between 1967 and 1982, 59 patients (33 with gynecologic malignancies and 26 with malignant tumors of the genitourinary system) received irradiation of 40 Gy or more for metastases to the para-aortic lymph nodes, in addition to pelvic irradiation. Disease in the para-aortic lymph nodes was controlled in 50 patients; the treatment failed in nine. Moderately acute side effects were seen in 25 patients, but none was severe. Late effects of irradiation were moderate in five patients and severe in three. Thirty patients are alive at 5 years. The benefits of local control and prolonged disease-free survival appear to outweigh considerably the risk of late effects from pelvic and para-aortic irradiation for advanced malignant tumors of the genitourinary system

  5. Study of positional dependence of dose to bladder, pelvic wall and rectal points in High-Dose-Rate Brachytherapy in cervical cancer patients

    International Nuclear Information System (INIS)

    Talluri, Anil Kumar; Alluri, Krishnam Raju; Gudipudi, Deleep Kumar; Ahamed, Shabbir; Sresty, Madhusudhana M.; Reddy, Aparna Yarrama

    2013-01-01

    The objective of the study is to examine the variation in doses to, Bladder, pelvic wall and Rectal Points when a patient is simulated in Supine (S Position) and Lithotomy M shaped positions (LM Position), respectively as part of Intracavitary Brachytherapy in Cervical Cancer patients. Patients (n = 19) were simulated and orthogonal images were taken in S Position and LM Positions on a physical simulator. Digital orthogonal X-ray images were transferred to Brachyvision Treatment Planning System via Dicom to generate treatment plans. Radio opaque dye of 7 ml was injected into the Foley bulb for identification and digitization of International Commission on Radiological Units and Measurements (ICRU) Bladder point. Pelvic side wall points were marked in accordance with ICRU 38 recommendations. A Rectal tube containing dummy source marker wire was used to identify Rectal Point. Students' t-test was used to analyze the results. Doses in LM Position were lower and statistically significant when compared to S Position for ICRU Bladder Point, pelvic walls and Rectal Point. It was observed that movement of applicator could be the reason for the variations in doses between the two positions. Bladder, pelvic wall and rectal points systematically registered lower doses in LM Position as compared to S Position. (author)

  6. Impact of hip prosthesis on dose distribution of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Ren Jiangping; Zhang Songfang; Zhu Qibao; Guo Jianxin; Zha Yuanzi

    2011-01-01

    Objective: To study the scattering effect of Co-Cr-Mo hip prosthesis which was high Z material for patients undergoing pelvic irradiation. Methods: The hip prosthesis was set in water phantom (30 cm x 30 cm x 30 cm), determining points were chosen on the entrance side of both 6 MV and 10 MV beams at the distance of 0.5 cm, 1.0 cm, 2.0 cm to the hip prosthesis, and also on the exit side of both 6 MV and 10 MV beams at the distance of 3.0 cm, 5.0 cm, 7.0 cm to the hip prostheses. Dose behind the hip prosthesis at depths of 5.0 cm and 10.0 cm for 6 MV and 10 MV beams are also measured. Results: The dose deviation on the beams' entrance side is between 0 to 5.0%, the backscatter effect was more obviously with the higher energy beam. The dose deviation on the beams' exit side was between 21.6%-30.8%. With the same field size and depth, dose deviation becomes smaller when the beam energy was higher; while with the same energy and depth, dose deviation becomes smaller when the field size was bigger. Dose profiles behind the head of the hip prosthesis indicate obvious attenuation of the beam. Conclusions: Beam arrangements that avoid the prosthesis should be considered first or we should at least reduce the weight of the beam that pass through the prosthesis. (authors)

  7. Evaluation of the Entrance Surface Dose (ESD and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-06-01

    Full Text Available Background Patients' dosimetry is crucial in order to enhance radiation protection optimization and to deliver low radiation dose to the patients in a radiological procedure. The aim of this study was to assess the entrance surface dose (ESD and radiation dose to the radiosensitive organs in pediatric pelvic radiography. Materials and Methods The studied population included 98 pediatric patients of both genders referred to anteroposterior (AP projection of pelvic radiography. The radiation dose was directly measured using high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD-GR200. Two TLDs were placed at the center point of the radiation field to measure the ESD of pelvis. Moreover for each patient, 2 TLDs were placed upon each eyelid, 2 TLDs upon each breast, 2 TLDs upon the surface anatomical position of the thyroid gland and finally 2 TLDs at the surface anatomical position of the gonads to measure the received dose. Results The ESD ± standard deviation for AP pelvic radiography was obtained 591.7±76 µGy. Statistically significant difference was obtained between organs located outside and inside of the radiation field with respect to dose received (P

  8. Pelvic Nodal Dosing With Registration to the Prostate: Implications for High-Risk Prostate Cancer Patients Receiving Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Kishan, Amar U.; Lamb, James M.; Jani, Shyam S.; Kang, Jung J.; Steinberg, Michael L.; King, Christopher R.

    2015-01-01

    Purpose: To determine whether image guidance with rigid registration (RR) to intraprostatic markers (IPMs) yields acceptable coverage of the pelvic lymph nodes in the context of a stereotactic body radiation therapy (SBRT) regimen. Methods and Materials: Four to seven kilovoltage cone-beam CTs (CBCTs) from 12 patients with high-risk prostate cancer were analyzed, allowing approximation of an SBRT regimen. The nodal clinical target volume (CTV N ) and bladder were contoured on all kilovoltage CBCTs. The V 100 CTV N , expressed as a ratio to the same parameter on the initial plan, and the magnitude of translational shift between RR to the IPMs versus RR to the pelvic bones, were computed. The ability of a multimodality bladder filling protocol to minimize bladder height variation was assessed in a separate cohort of 4 patients. Results: Sixty-five CBCTs were assessed. The average V 100 CTV N was 92.6%, but for a subset of 3 patients the average was 80.0%, compared with 97.8% for the others (P<.0001). The average overall and superior–inferior axis magnitudes of the bony-to-fiducial translations were significantly larger in the subgroup with suboptimal nodal coverage (8.1 vs 3.9 mm and 5.8 vs 2.4 mm, respectively; P<.0001). Relative bladder height changes were also significantly larger in the subgroup with suboptimal nodal coverage (42.9% vs 18.5%; P<.05). Use of a multimodality bladder-filling protocol minimized bladder height variation (P<.001). Conclusion: A majority of patients had acceptable nodal coverage after RR to IPMs, even when approximating SBRT. However, a subset of patients had suboptimal nodal coverage. These patients had large bony-to-fiducial translations and large variations in bladder height. Nodal coverage should be excellent if the superior–inferior axis bony-to-fiducial translation and the relative bladder height change (both easily measured on CBCT) are kept to a minimum. Implementation of a strict bladder filling protocol may achieve this

  9. Postoperative high-dose pelvic radiotherapy for N+ prostate cancer: Toxicity and matched case comparison with postoperative prostate bed-only radiotherapy

    International Nuclear Information System (INIS)

    Van Praet, Charles; Ost, Piet; Lumen, Nicolaas; De Meerleer, Gert; Vandecasteele, Katrien; Villeirs, Geert; Decaestecker, Karel; Fonteyne, Valérie

    2013-01-01

    Purpose: To report on toxicity of postoperative high-dose whole-pelvis radiotherapy (WPRT) with androgen deprivation therapy for lymph node metastasized (N1) prostate cancer (PC). To perform a matched-case analysis to compare this toxicity profile to postoperative prostate bed-only radiotherapy (PBRT). Materials and methods: Forty-eight N1-PC patients were referred for WPRT and 239 node-negative patients for PBRT. Patients were matched 1:1 according to pre-treatment demographics, symptoms, treatment and tumor characteristics. Mean dose to the prostate bed was 75 Gy (WPRT–PBRT) and 54 Gy to the elective nodes (WPRT) in 36 or 37 fractions. End points are genito-urinary (GU) and gastro-intestinal (GI) toxicity. Results: After WPRT, 35% developed grade 2 (G2) and 4% G3 acute GU toxicity. Acute GI toxicity developed in 42% (G2). Late GU toxicity developed in 36% (G2) and 7% (G3). One patient had G4 incontinence. Recuperation occurred in 59%. Late GI toxicity developed in 25% (G2) with 100% recuperation. Incidence of acute and late GI toxicity was higher following WPRT compared to PBRT (p ⩽ 0.041). GU toxicity was similar. With WPRT mean dose to bladder and rectosigmoid were higher. Conclusions: Postoperative high-dose WPRT comes at the cost of a temporary increase in G2. GI toxicity compared to PBRT because larger volumes of rectosigmoid are irradiated

  10. Does initial 45Gy of pelvic intensity-modulated radiotherapy reduce late complications in patients with locally advanced cervical cancer? A cohort control study using definitive chemoradiotherapy with high-dose rate brachytherapy

    International Nuclear Information System (INIS)

    Chen, Shang-Wen; Liang, Ji-An; Hung, Yao-Ching; Yeh, Lian-Shung; Chang, Wei-Chun; Lin, Wu-Chou; Chien, Chun-Ru

    2013-01-01

    Comparing initial 45 Gy of pelvic intensity-modulated radiation therapy (IMRT) and non-IMRT in terms of the late toxicities associated with advanced cervical cancer that has also been treated with definitive concurrent chemoradiotherapy and high-dose rate intracavitary brachytherapy (HDRICB). This retrospective study included 320 stage IB2-IIIB cervical cancer patients treated with CCRT (83 IMRT and 237 non-IMRT). The two groups had similar stage and HDRICB ratings. Following 45 Gy to the pelvis, HDRICB of 24 Gy in four courses was prescribed. Late toxicities, including rectal complications (RC), bladder complications (BC) and non-rectal intestinal injury (NRRII), were scored by the Common Terminology Criteria for Adverse Events. A logistic regression was used to estimate the odds ratio (OR) of the complications. With a median follow-up duration of 33 and 77 months for IMRT and non-IMRT, 33 patients had Grade 2 or higher late RC (7.2% IMRT, 11.4% non-IMRT), whereas that for BC was 40 (9.6% IMRT, 13.5% non-IMRT) and for NRRII was 48 (12.0% IMRT, 16.0% non-IMRT). The cumulative rate for total grade 3 or higher gastrointestinal or genitourinary toxicities was 8.4% and 11.8% (p = 0.33). IMRT did not reduce the OR for all endpoints; however, the ORs for rectum and bladder reference doses to Point A were associated with RC and BC. Locally advanced cervical cancer patients treated with initial 45Gy of pelvic IMRT and HDRICB have similar treatment-related late toxicities as those treated with non-IMRT. Optimization of the brachytherapy scheme is essential to minimize late toxicities

  11. High-dose chemotherapy with stem cell rescue in the primary treatment of metastatic and pelvic osteosarcoma: final results of the ISG/SSG II study.

    Science.gov (United States)

    Boye, Kjetil; Del Prever, Adalberto Brach; Eriksson, Mikael; Saeter, Gunnar; Tienghi, Amelia; Lindholm, Paula; Fagioli, Franca; Skjeldal, Sigmund; Ferrari, Stefano; Hall, Kirsten Sundby

    2014-05-01

    Patients with metastatic osteosarcoma at diagnosis or axial primary tumors have a poor prognosis. The aim of the study was to evaluate the feasibility and efficacy of intensified treatment with high-dose chemotherapy (HDCT) and stem cell rescue in this group. From May 1996 to August 2004, 71 patients were included in a Scandinavian-Italian single arm phase II study. Preoperative chemotherapy included methotrexate, doxorubicin, cisplatin and ifosfamide, and postoperative treatment consisted of two cycles of doxorubicin, one cycle of cyclophosphamide and etoposide and two courses of high-dose etoposide and carboplatin with stem cell rescue. Twenty-nine patients (43%) received two courses and 10 patients (15%) received one course of HDCT. HDCT was associated with significant toxicity, but no treatment-related deaths were recorded. Fourteen patients (20%) had disease progression before completion of the study protocol, and only 29/71 patients (41%) received the full planned treatment. Median event-free survival (EFS) was 18 months, and estimated 5-year EFS was 27%. Median overall survival (OS) was 34 months, and estimated 5-year OS was 31%. When patients who did not receive HDCT due to disease progression were excluded, there was no difference in EFS (P = 0.72) or OS (P = 0.49) between patients who did or did not receive HDCT. The administration of high-dose chemotherapy with stem cell rescue was feasible, but associated with significant toxicity. Patient outcome seemed comparable to previous studies using conventional chemotherapy. We conclude that HDCT with carboplatin and etoposide should not be further explored as a treatment strategy in high-risk osteosarcoma. © 2013 Wiley Periodicals, Inc.

  12. Dose-Effect Relationships for Individual Pelvic Floor Muscles and Anorectal Complaints After Prostate Radiotherapy

    International Nuclear Information System (INIS)

    Smeenk, Robert Jan; Hoffmann, Aswin L.; Hopman, Wim P.M.; Lin, Emile N.J. Th. van; Kaanders, Johannes H.A.M.

    2012-01-01

    Purpose: To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). Methods and Materials: In 48 patients treated for localized prostate cancer, the internal anal sphincter (IAS) muscle, the external anal sphincter (EAS) muscle, the puborectalis muscle (PRM), and the levator ani muscles (LAM) in addition to the anal wall (Awall) and rectal wall (Rwall) were retrospectively delineated on planning computed tomography scans. Dose parameters were obtained and compared between patients with and without fecal urgency, incontinence, and frequency. Dose-effect curves were constructed. Finally, the effect of an endorectal balloon, which was applied in 28 patients, was investigated. Results: The total volume of the pelvic floor muscles together was about three times that of the Awall. The PRM was exposed to the highest RT dose, whereas the EAS received the lowest dose. Several anal and rectal dose parameters, as well as doses to all separate pelvic floor muscles, were associated with urgency, while incontinence was associated mainly with doses to the EAS and PRM. Based on the dose-effect curves, the following constraints regarding mean doses could be deduced to reduce the risk of urgency: ≤30 Gy to the IAS; ≤10 Gy to the EAS; ≤50 Gy to the PRM; and ≤40 Gy to the LAM. No dose-effect relationships for frequency were observed. Patients treated with an endorectal balloon reported significantly less urgency and incontinence, while their treatment plans showed significantly lower doses to the Awall, Rwall, and all pelvic floor muscles. Conclusions: Incontinence-related complaints show specific dose-effect relationships to individual pelvic floor muscles. Dose constraints for each muscle can be identified for RT planning. When only the Awall is delineated, substantial components of the continence apparatus are

  13. Dose-effect relationships for individual pelvic floor muscles and anorectal complaints after prostate radiotherapy.

    Science.gov (United States)

    Smeenk, Robert Jan; Hoffmann, Aswin L; Hopman, Wim P M; van Lin, Emile N J Th; Kaanders, Johannes H A M

    2012-06-01

    To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). In 48 patients treated for localized prostate cancer, the internal anal sphincter (IAS) muscle, the external anal sphincter (EAS) muscle, the puborectalis muscle (PRM), and the levator ani muscles (LAM) in addition to the anal wall (Awall) and rectal wall (Rwall) were retrospectively delineated on planning computed tomography scans. Dose parameters were obtained and compared between patients with and without fecal urgency, incontinence, and frequency. Dose-effect curves were constructed. Finally, the effect of an endorectal balloon, which was applied in 28 patients, was investigated. The total volume of the pelvic floor muscles together was about three times that of the Awall. The PRM was exposed to the highest RT dose, whereas the EAS received the lowest dose. Several anal and rectal dose parameters, as well as doses to all separate pelvic floor muscles, were associated with urgency, while incontinence was associated mainly with doses to the EAS and PRM. Based on the dose-effect curves, the following constraints regarding mean doses could be deduced to reduce the risk of urgency: ≤ 30 Gy to the IAS; ≤ 10 Gy to the EAS; ≤ 50 Gy to the PRM; and ≤ 40 Gy to the LAM. No dose-effect relationships for frequency were observed. Patients treated with an endorectal balloon reported significantly less urgency and incontinence, while their treatment plans showed significantly lower doses to the Awall, Rwall, and all pelvic floor muscles. Incontinence-related complaints show specific dose-effect relationships to individual pelvic floor muscles. Dose constraints for each muscle can be identified for RT planning. When only the Awall is delineated, substantial components of the continence apparatus are excluded. Copyright © 2012 Elsevier Inc. All rights

  14. Evaluation of the anode heel effect on the testes dose during pelvic radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-05-01

    Full Text Available Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male patients undergoing pelvic radiography. Methods: This is a cross-sectional study, conducted at one of the teaching hospitals of Ahvaz, Jundishapur University of Medical Science Ahvaz, Iran, from September 2015 to March 2016. In order to measure the profile of radiation intensity variation, 13 paired sets of high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD aligned on the cathode-anode central axis upon the table and then irradiated using routine exposure parameters. The anode of X-ray tube was positioned toward the feet for 40 patients and toward the head for 39 patients undergoing pelvic radiography. For measure the entrance skin dose (ESD, 8 TLD chips were located on the central point of the radiation field and 5 TLDs were located on the testes position to measure the dose received. Results: Radiation intensity profile showed that radiation intensity decrease from the cathode to the anode side. Discrepancy of radiation intensity on central axis of cathode-anode was calculated about 35%. The radiation dose received by the testes was 26.74% lower for patients the anode directed toward the feet, compared to the patients in which the anode directed toward the head (FTC: 1.260±0.296 mGy, FTA: 0.923±0.167 mGy, P<0.05. There was no meaningful difference for the measured ESD of pelvis between two groups of patients (FTC: 1.256±0.315 mGy, FTA: 1.195±0.205 mGy, P=0.788. Conclusion: In pelvic radiography, positioning of testes directed to the anode of X-ray tube can decrease the receive dose.

  15. Venous thromboembolism: Additional diagnostic value and radiation dose of pelvic CT venography in patients with suspected pulmonary embolism

    International Nuclear Information System (INIS)

    Reichert, Miriam; Henzler, Thomas; Krissak, Radko; Apfaltrer, Paul; Huck, Kurt; Buesing, Karen; Sueselbeck, Tim; Schoenberg, Stefan O.; Fink, Christian

    2011-01-01

    detection of VTE, because the additional radiation dose is high and isolated pelvic DVT is very rare. Venous imaging of the legs (preferably by radiation-free ultrasound) is sufficient for the diagnosis of underlying DVT in patients with suspected PE.

  16. Associations between volume changes and spatial dose metrics for the urinary bladder during local versus pelvic irradiation for prostate cancer.

    Science.gov (United States)

    Casares-Magaz, Oscar; Moiseenko, Vitali; Hopper, Austin; Pettersson, Niclas Johan; Thor, Maria; Knopp, Rick; Deasy, Joseph O; Muren, Ludvig Paul; Einck, John

    2017-06-01

    Inter-fractional variation in urinary bladder volumes during the course of radiotherapy (RT) for prostate cancer causes deviations between planned and delivered doses. This study compared planned versus daily cone-beam CT (CBCT)-based spatial bladder dose distributions, for prostate cancer patients receiving local prostate treatment (local treatment) versus prostate including pelvic lymph node irradiation (pelvic treatment). Twenty-seven patients (N = 15 local treatment; N = 12 pelvic treatment) were treated using daily image-guided RT (1.8 Gy@43-45 fx), adhering to a full bladder/empty rectum protocol. For each patient, 9-10 CBCTs were registered to the planning CT, using the clinically applied translations. The urinary bladder was manually segmented on each CBCT, 3 mm inner shells were generated, and semi and quadrant sectors were created using axial/coronal cuts. Planned and delivered DVH metrics were compared across patients and between the two groups of treatment (t-test, p bladder volume variations and the dose-volume histograms (DVH) of the bladder and its sectors were evaluated (Spearman's rank correlation coefficient, r s ). Bladder volumes varied considerably during RT (coefficient of variation: 16-58%). The population-averaged planned and delivered DVH metrics were not significantly different at any dose level. Larger treatment bladder volumes resulted in increased absolute volume of the posterior/inferior bladder sector receiving intermediate-high doses, in both groups. The superior bladder sector received less dose with larger bladder volumes for local treatments (r s  ± SD: -0.47 ± 0.32), but larger doses for pelvic treatments (r s  ± SD: 0.74 ± 0.24). Substantial bladder volume changes during the treatment course occurred even though patients were treated under a full bladder/daily image-guided protocol. Larger bladder volumes resulted in less bladder wall spared at the posterior-inferior sector, regardless the

  17. Pelvic nodal dose escalation with prostate hypofractionation using conformal avoidance defined (H-CAD) intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Hong, Theodore S.; Tome, Wolfgang A.; Jaradat, Hazim; Raisbeck, Bridget M.; Ritter, Mark A.

    2006-01-01

    % of both the PTV 70 (prostate) and PTV 56 (nodes). The EUDs for PTV 70 and PTV 56 were greater than prescription dose for all eight plans. Analysis of bio-effective DVHs demonstrated similar amounts of small bowel receiving >45 Gy for H-CAD and sequential plans, in spite of the significantly higher dose to which H-CAD treated the pelvic nodes. The treatment was well tolerated in the eight treated patients in that no grade 2 or higher acute gastrointestinal toxicities were seen. Prostate hypofractionation with concurrent conformal avoidance-based pelvic IMRT for high risk prostate cancer represents an efficient and promising method for achieving dose escalation both of pelvic lymph nodes and the prostate with modest acute toxicity. Unlike a vascular-guided targeting approach, conformal avoidance has the potential advantage of also encompassing at-risk nodes that are not contained within major nodal chains. A phase II trial to more thoroughly examine this treatment approach is currently underway

  18. Role of prostate dose escalation in patients with greater than 15% risk of pelvic lymph node involvement

    International Nuclear Information System (INIS)

    Jacob, Rojymon; Hanlon, Alexandra L.; Horwitz, Eric M.; Movsas, Benjamin; Uzzo, Robert G.; Pollack, Alan

    2005-01-01

    Purpose: To determine whether the radiation dose is a determinant of clinical outcome in patients with a lymph node risk of >15% treated using whole pelvic (WP), partial pelvic (PP), or prostate only (PO) fields. Methods and materials: A total of 420 patients with prostate cancer treated with three-dimensional conformal radiotherapy with or without short-term androgen deprivation (STAD) between June 1989 and July 2000 were included in this study. Patients had an initial pretreatment prostate-specific antigen level of 15% in the patient population studied. These data suggest that the primary tumor takes precedence over lymph node coverage or the use of STAD. Doses >70 Gy are of paramount importance in such intermediate- and high-risk patients

  19. Dose-effect relationships for individual pelvic floor muscles and anorectal complaints after prostate radiotherapy.

    NARCIS (Netherlands)

    Smeenk, R.J.; Hoffmann, A.L.; Hopman, W.P.M.; Lin, E.N.J.T. van; Kaanders, J.H.A.M.

    2012-01-01

    PURPOSE: To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). METHODS AND MATERIALS: In 48 patients treated for localized prostate

  20. Barriers to Pelvic Floor Physical Therapy Regarding Treatment of High-Tone Pelvic Floor Dysfunction.

    Science.gov (United States)

    Zoorob, Dani; Higgins, Margaret; Swan, Kimberly; Cummings, Jennifer; Dominguez, Sarah; Carey, Erin

    Chronic pelvic pain is a prevalent and debilitating condition with a wide range of etiologies. An estimated 30% to 70% of chronic pelvic cases involve musculoskeletal component pain including high-tone pelvic floor dysfunction (HTPFD). Pelvic floor physical therapy has been shown to be a beneficial treatment for HTPFD, yet many patients do not have access to this treatment. The objective of this study was to identify the barriers preventing patients from following through with the first-line management, physical therapy. Participants with a diagnosis of HTPFD (n = 154) were identified from the list of referrals sent from the obstetrics and gynecology department to an affiliated PFPT center. Participants were contacted and asked to complete a phone survey addressing demographics and perceived barriers to care. Responses were collected in REDCap. Univariate and bivariate analyses were performed using a statistical analysis software. Seventy surveys were completed. The top barriers identified by participants were financial constraints (51.4%), perceived lack of utility (37.1%), time constraints (30.0%), and travel issues (18.6%); 84.4% of participants had 1 or more comorbid pain condition. Whereas 51.4% expressed some level of anxiety regarding the PFPT option, only 9.6% of participants did not start treatment because of fear of treatment. The majority of treatment barriers identified were concrete restraints, with insurance noncoverage and time constraints being the top issues. A fair number of participants expressed anxiety about the treatment or felt they received unclear explanations of the treatment. These are areas in which providers can potentially alleviate some barriers to care.

  1. Comparison of the kidney dose between supine and prone position for pelvic and periaortic irradiation

    International Nuclear Information System (INIS)

    Mison, Chun; Haejin, Kang; Juree, Kim; Heesuk, Ryu; Hyunsoo, Shin

    1996-01-01

    We compared the doses received by the kidney in supine and prone positions for pelvic and periaortic irradiation. Kidney locations were verified by CT images taken with patients in the same position as during the treatment. Due to the shift of the kidney anteriorly during prone position, treatment in supine position delivered a much lower dose to most of the kidney than treatment in the prone position. Therefore, for periaortic irradiation treatment, the supine position should be considered to minimize the dose to the kidneys, even though the prone position with a belly board can reduce the dose to the small bowel

  2. Dose-volume effects for pelvic bone marrow in predicting hematological toxicity in prostate cancer radiotherapy with pelvic node irradiation.

    Science.gov (United States)

    Sini, Carla; Fiorino, Claudio; Perna, Lucia; Noris Chiorda, Barbara; Deantoni, Chiara Lucrezia; Bianchi, Marco; Sacco, Vincenzo; Briganti, Alberto; Montorsi, Francesco; Calandrino, Riccardo; Di Muzio, Nadia; Cozzarini, Cesare

    2016-01-01

    To prospectively identify clinical/dosimetric predictors of acute/late hematologic toxicity (HT) in chemo-naÏve patients treated with whole-pelvis radiotherapy (WPRT) for prostate cancer. Data of 121 patients treated with adjuvant/salvage WPRT were analyzed (static-field IMRT n=19; VMAT/Rapidarc n=57; Tomotherapy n=45). Pelvic bone marrow (BM) was delineated as ilium (IL), lumbosacral, lower and whole pelvis (WP), and the relative DVHs were calculated. HT was graded both according to CTCAE v4.03 and as variation in percentage relative to baseline. Logistic regression was used to analyze association between HT and clinical/DVHs factors. Significant differences (p<0.005) in the DVH of BM volumes between different techniques were found: Tomotherapy was associated with larger volumes receiving low doses (3-20 Gy) and smaller receiving 40-50 Gy. Lower baseline absolute values of WBC, neutrophils and lymphocytes (ALC) predicted acute/late HT (p ⩽ 0.001). Higher BM V40 was associated with higher risk of acute Grade3 (OR=1.018) or late Grade2 lymphopenia (OR=1.005). Two models predicting lymphopenia were developed, both including baseline ALC, and BM WP-V40 (AUC=0.73) and IL-V40+smoking (AUC=0.904) for acute/late respectively. Specific regions of pelvic BM predicting acute/late lymphopenia, a risk factor for viral infections, were identified. The 2-variable models including specific constraints to BM may help reduce HT. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, R.; McCarty, M. [Div. of Radiology, South Cleveland Hospital, South Tees Acute Hospitals NHS Trust, Marton Road, Middlesbrough, Cleveland (United Kingdom); McCallum, H.M. [Regional Medical Physics Dept., South Cleveland Hospital, Middlesbrough (United Kingdom); Montgomery, R. [Dept. of Orthopaedics, South Tees Hospitals NITS Trust, Middlesbrough (United Kingdom); Aszkenasy, M. [Tees and North East Yorkshire NHS Trust, West Lane Hospital, Middlesbrough (United Kingdom)

    2001-05-01

    Background. An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. Objective. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Materials and methods. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Results. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83 %, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Conclusion. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving. (orig.)

  4. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy.

    Science.gov (United States)

    Waugh, R; McCallum, H M; McCarty, M; Montgomery, R; Aszkenasy, M

    2001-05-01

    An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83%, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving.

  5. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy

    International Nuclear Information System (INIS)

    Waugh, R.; McCarty, M.; McCallum, H.M.; Montgomery, R.; Aszkenasy, M.

    2001-01-01

    Background. An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. Objective. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Materials and methods. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Results. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83 %, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Conclusion. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving. (orig.)

  6. Options for radiation dose optimisation in pelvic digital radiography: A phantom study

    International Nuclear Information System (INIS)

    Manning-Stanley, Anthony S.; Ward, Anthony J.; England, Andrew

    2012-01-01

    Purpose: To investigate the effects of phantom orientation and AEC chamber selection on radiation dose and image quality (IQ) for digital radiography (DR) examinations of the pelvis. Methods: A phantom study was conducted using a DR detector, utilising all AEC chamber combinations. Current recommended orientation (Cr-AEC) was with the outer AEC chambers cranially orientated. mAs (given), source-to-skin distance and kV p data facilitated entrance surface dose and effective dose calculations. Six anatomical areas were blindly graded by two observers (3-point scale) for IQ. Statistical differences in radiation dose were determined using the paired Student’s t-test. IQ data was analysed for inter-observer variability (ICC) and statistical differences (Wilcoxon test). Results: Switching phantom orientation (caudally orientated outer AEC chambers: Ca-AEC) reduced mean radiation dose by 36.8%, (p < 0.001). A minor reduction in median IQ (15.5 vs. 15) was seen (p < 0.001). One Ca-AEC orientated image (1.6%) had all anatomical areas graded ‘inadequate’ by at least one observer; all other images were considered ‘adequate’ for all areas. In the Ca-AEC orientation, at least a 44% dose reduction was achievable (p < 0.001) when only the outer AEC chambers were used. In the Cr-AEC orientation, at least 11% dose reduction was achieved (p < 0.001); here the central chamber was used alone, or in combination. IQ scores fell, but remained ‘adequate’. Conclusion: Switching pelvic orientation relative to AEC chamber position can optimise radiation dose during pelvic radiography. AEC chamber position should be clearly marked on equipment to facilitate this. AEC selection should be an active process.

  7. Influence of Routine MV CBCT Usage on Dose Distribution in Pelvic Radiotherapy

    International Nuclear Information System (INIS)

    Faj, D.; Kasabasic, M.; Ivkovic, A.; Tomas, I.; Jurkovic, S.

    2013-01-01

    The pelvic radiotherapy is a standard treatment for patients with cervical, uterine and rectal carcinomas. During radiation treatment open tabletop device or bellyboard is used to reduce the side effects of healthy surrounding tissue. Patients are continually adjusting to the bellyboard during the treatment which causes geometrical and dosage uncertainties and influences the results of the treatment. Therefore, to reduce these uncertainties, megavoltage cone-beam computed tomography (MV CBCT) system is used. The objective of this research was to evaluate the image acquisition dose delivered to patients from MV CBCT. MV CBCT imaging was simulated on 15 patients using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The influence of the routine MV CBCT usage on treatment plan was investigated by analyzing the changes in dose volume histograms, mean values and maximum doses in the planning volumes. Simulations have shown that daily usage of MV CBCT causes differences in the dose volume histograms. Moreover, for every patient mean value exceeded prescribed tolerance (±1% of the prescribed dose) and maximum value exceeded recommended maximum of 107% of the prescribed dose. The results have shown that MV CBCT dose to the patient should be a part of the RT plan.(author)

  8. Proposed Rectal Dose Constraints for Patients Undergoing Definitive Whole Pelvic Radiotherapy for Clinically Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Chan, Linda W.; Xia Ping; Gottschalk, Alexander R.; Akazawa, Michelle; Scala, Matthew; Pickett, Barby M.S.; Hsu, I-C.; Speight, Joycelyn; Roach, Mack

    2008-01-01

    Purpose: Although several institutions have reported rectal dose constraints according to threshold toxicity, the plethora of trials has resulted in multiple, confusing dose-volume histogram recommendations. A set of standardized, literature-based constraints for patients undergoing whole pelvic radiotherapy (RT) for prostate cancer would help guide the practice of prostate RT. The purpose of this study was to develop these constraints, demonstrate that they are achievable, and assess the corresponding rectal toxicity. Methods and Materials: An extensive literature search identified eight key studies relating dose-volume histogram data to rectal toxicity. A correction factor was developed to address differences in the anatomic definition of the rectum across studies. The dose-volume histogram constraints recommended by each study were combined to generate the constraints. The data from all patients treated with definitive intensity-modulated RT were then compared against these constraints. Acute rectal toxicity was assessed. Results: A continuous, proposed rectal dose-constraint curve was generated. Intensity-modulated RT not only met this constraint curve, but also was able to achieve at least 30-40% lower dose to the rectum. The preliminary clinical results were also positive: 50% of patients reported no acute bowel toxicity, 33% reported Grade 1 toxicity, and 17% reported Grade 2 toxicity. No patients reported Grade 3-4 acute rectal toxicity. Conclusions: In this study, we developed a set of proposed rectal dose constraints. This allowed for volumetric assessment of the dose-volume relationship compared with single dose-volume histogram points. Additional research will be performed to validate this threshold as a class solution for rectal dose constraints

  9. Differences in male and female spino-pelvic alignment in asymptomatic young adults: a three-dimensional analysis using upright low-dose digital biplanar X-rays.

    Science.gov (United States)

    Janssen, Michiel M A; Drevelle, Xavier; Humbert, Ludovic; Skalli, Wafa; Castelein, René M

    2009-11-01

    A three-dimensional analysis of spino-pelvic alignment in 60 asymptomatic young adult males and females. To analyze the differences in sagittal spino-pelvic alignment in a group of asymptomatic young adult males and females and describe gender specific reference values. Several spinal disorders like idiopathic scoliosis and Scheuermann's disease have a well-known sex-related prevalence ratio. As spino-pelvic alignment plays an important role in spinal biomechanics, it is imperative to analyze possible differences between the male and female spino-pelvic alignment. Furthermore, in spinal fusion surgery, normal sagittal balance should be recreated as closely as possible. An innovative biplanar ultra low-dose radiographic technique was used to obtain three-dimensional reconstructions of the spine (T1-L5), sacrum, and pelvis in a freestanding position of 30 asymptomatic young male and 30 young female adults. Values were calculated for thoracic kyphosis (T4-T12), lumbar lordosis (L1-S1), total and regional lumbopelvic lordosis (PRT12, PRL2, PRL4, and PRL5), sagittal plumb line of T1, T4, and T9 (HAT1, HAT4, and HAT9), T1-L5 sagittal spinal inclination, T9 sagittal offset, and pelvic parameters (pelvic tilt, sacral slope, and pelvic incidence). In addition, vertebral inclination in the sagittal plane of each vertebra was measured. Differences in spino-pelvic alignment between the sexes were analyzed. The female spine was more dorsally inclined (11 degrees vs. 8 degrees ; P = 0.003). High thoracic and thoracolumbar vertebrae were more dorsally inclined in women than in men. Thoracic kyphosis, lumbar lordosis, regional lumbopelvic lordosis, sagittal plumb lines, T9 sagittal offset, and pelvic parameters were not statistically different between the sexes. These results indicate that the female spine is definitely different from the male spine. The spine as whole and individual vertebrae in certain regions of the normal spine is more backwardly inclined in females than in

  10. High resolution MR imaging of the hip using pelvic phased-array coil

    Energy Technology Data Exchange (ETDEWEB)

    Niitsu, Mamoru; Mishima, Hajime; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    1997-01-01

    A pelvic phased-array coil was applied to obtain high resolution MR images of the hip. Three-mm-thick fast spin-echo images were obtained in seven hips. Images with a pelvic coil enhanced delineation of acetabular labrum and articular cartilage more clearly than those with a body coil or flexible-surface coil. The use of a pelvic coil in imaging of the hip may be of diagnostic value because of its superior delineation. (author)

  11. Dosimetric Study of Pelvic Proton Radiotherapy for High-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    Chera, Bhishamjit S.; Vargas, Carlos; Morris, Christopher G.; Louis, Debbie; Flampouri, Stella; Yeung, Daniel; Duvvuri, Srividya; Li Zuofeng; Mendenhall, Nancy Price

    2009-01-01

    Purpose: To compare dose distributions in targeted tissues (prostate, seminal vesicles, pelvic regional nodes) and nontargeted tissues in the pelvis with intensity-modulated radiotherapy (IMRT) and forward-planned, double-scattered, three-dimensional proton radiotherapy (3D-PRT). Methods and Materials: IMRT, IMRT followed by a prostate 3D-PRT boost (IMRT/3D-PRT), and 3D-PRT plans were created for 5 high-risk prostate cancer patients (n = 15 plans). A 78-CGE/Gy dose was prescribed to the prostate and proximal seminal vesicles and a 46-CGE/Gy was prescribed to the pelvic nodes. Various dosimetric endpoints were compared. Results: Target coverage of the prostate and nodal planning target volumes was adequate for all three plans. Compared with the IMRT and IMRT/3D-PRT plans, the 3D-PRT plans reduced the mean dose to the rectum, rectal wall, bladder, bladder wall, small bowel, and pelvis. The relative benefit of 3D-PRT (vs IMRT) at reducing the rectum and rectal wall V5-V40 was 53% to 71% (p < 0.05). For the bladder and bladder wall, the relative benefit for V5 to V40 CGE/Gy was 40% to 63% (p < 0.05). The relative benefit for reducing the volume of small bowel irradiated from 5 to 30 CGE/Gy in the 3D-PRT ranged from 62% to 69% (p < 0.05). Use of 3D-PRT did not produce the typical low-dose 'bath' of radiation to the pelvis seen with IMRT. Femoral head doses were higher for the 3D-PRT. Conclusions: Use of 3D-PRT significantly reduced the dose to normal tissues in the pelvis while maintaining adequate target coverage compared with IMRT or IMRT/3D-PRT. When treating the prostate, seminal vesicles, and pelvic lymph nodes in prostate cancer, proton therapy may improve the therapeutic ratio beyond what is possible with IMRT.

  12. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  13. Male gonadal dose an adjuvant 3-D-pelvic irradiation after anterior resection of rectal cancer. Influence to fertility

    International Nuclear Information System (INIS)

    Piroth, M.D.; Hensley, F.; Wannenmacher, M.; Zierhut, D.

    2003-01-01

    Background: Rectal cancer is a common malignant disease and occurs not infrequently in younger men. We verified the dose to the testes from scattered radiation in adjuvant pelvic irradiation following anterior resection of rectal cancer. Patients and Method: We measured the scattered gonadal dose of 18 patients in vivo with thermoluminescence detectors, which were fixed on four defined points on the scrotum during radiation on three consecutive days. All patients were treated three-dimensionally planned using a three-field box lying in prone position in a bellyboard. A total dose of 50.4 Gy was given in 28 fractions of 1.8 Gy. From 45 up to 50.4 Gy the radiation fields were modified to lateral-opposing fields which were shortened from the top to protect the small bowel. Results: The mean gonadal dose per fraction of all patients was 0.057 Gy (median 0.05 Gy) with a range between 0.035 and 0.114 Gy. The standard deviation was 0.02 Gy. The calculated cumulative mean gonadal dose after 28 fractions was 1.60 Gy (0.98-3.19 Gy). Conclusions: Germinal epithelium is very sensitive to low-dose irradiation, according to a negative fractionation effect. It is known that gonadal total doses of 1 Gy with single doses of 0.03-0.05 Gy can result in a temporary azoospermia with following recovery in most cases. If gonadal total doses exceed 1.5 Gy a substantial increase in irreversible azoospermia must be expected. With respect to the data reported in the literature our measured mean gonadal total dose of 1.60 Gy will lead with high probability to an irreversible infertility. Because of the small number of patients in our study, the data must be interpreted with caution, however, it is very important in patient's informed consent to draw attention to the high risk of infertility. The possibility of sperm cryoconservation should be discussed with the patient. (orig.) [de

  14. Evaluation of automatic exposure control system chamber for the dose optimization when examining pelvic in digital radiography.

    Science.gov (United States)

    Kim, Sung-Chul; Lee, Hae-Kag; Lee, Yang-Sub; Cho, Jae-Hwan

    2015-01-01

    We found a way to optimize the image quality and reduce the exposure dose of patients through the proper activity combination of the automatic exposure control system chamber for the dose optimization when examining the pelvic anteroposterior side using the phantom of the human body standard model. We set 7 combinations of the chamber of automatic exposure control system. The effective dose was yielded by measuring five times for each according to the activity combination of the chamber for the dose measurement. Five radiologists with more than five years of experience evaluated the image through picture archiving and communication system using double blind test while classifying the 6 anatomical sites into 3-point level (improper, proper, perfect). When only one central chamber was activated, the effective dose was found to be the highest level, 0.287 mSv; and lowest when only the top left chamber was used, 0.165 mSv. After the subjective evaluation by five panel members on the pelvic image was completed, there was no statistically meaningful difference between the 7 chamber combinations, and all had good image quality. When testing the pelvic anteroposterior side with digital radiography, we were able to reduce the exposure dose of patients using the combination of the top right side of or the top two of the chamber.

  15. Standard high-resolution pelvic MRI vs. low-resolution pelvic MRI in the evaluation of deep infiltrating endometriosis

    International Nuclear Information System (INIS)

    Scardapane, Arnaldo; Lorusso, Filomenamila; Ferrante, Annunziata; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Scioscia, Marco

    2014-01-01

    To compare the capabilities of standard pelvic MRI with low-resolution pelvic MRI using fast breath-hold sequences to evaluate deep infiltrating endometriosis (DIE). Sixty-eight consecutive women with suspected DIE were studied with pelvic MRI. A double-acquisition protocol was carried out in each case. High-resolution (HR)-MRI consisted of axial, sagittal, and coronal TSE T2W images, axial TSE T1W, and axial THRIVE. Low-resolution (LR)-MRI was acquired using fast single shot (SSH) T2 and T1 images. Two radiologists with 10 and 2 years of experience reviewed HR and LR images in two separate sessions. The presence of endometriotic lesions of the uterosacral ligament (USL), rectovaginal septum (RVS), pouch of Douglas (POD), and rectal wall was noted. The accuracies of LR-MRI and HR-MRI were compared with the laparoscopic and histopathological findings. Average acquisition times were 24 minutes for HR-MRI and 7 minutes for LR-MRI. The more experienced radiologist achieved higher accuracy with both HR-MRI and LR-MRI. The values of sensitivity, specificity, PPV, NPV, and accuracy did not significantly change between HR and LR images or interobserver agreement for all of the considered anatomic sites. LR-MRI performs as well as HR-MRI and is a valuable tool for the detection of deep endometriosis extension. (orig.)

  16. Standard high-resolution pelvic MRI vs. low-resolution pelvic MRI in the evaluation of deep infiltrating endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Scardapane, Arnaldo; Lorusso, Filomenamila; Ferrante, Annunziata; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe [University Hospital ' ' Policlinico' ' of Bari, Interdisciplinary Department of Medicine, Bari (Italy); Scioscia, Marco [Sacro Cuore Don Calabria General Hospital, Department of Obstetrics and Gynecology, Negrar, Verona (Italy)

    2014-10-15

    To compare the capabilities of standard pelvic MRI with low-resolution pelvic MRI using fast breath-hold sequences to evaluate deep infiltrating endometriosis (DIE). Sixty-eight consecutive women with suspected DIE were studied with pelvic MRI. A double-acquisition protocol was carried out in each case. High-resolution (HR)-MRI consisted of axial, sagittal, and coronal TSE T2W images, axial TSE T1W, and axial THRIVE. Low-resolution (LR)-MRI was acquired using fast single shot (SSH) T2 and T1 images. Two radiologists with 10 and 2 years of experience reviewed HR and LR images in two separate sessions. The presence of endometriotic lesions of the uterosacral ligament (USL), rectovaginal septum (RVS), pouch of Douglas (POD), and rectal wall was noted. The accuracies of LR-MRI and HR-MRI were compared with the laparoscopic and histopathological findings. Average acquisition times were 24 minutes for HR-MRI and 7 minutes for LR-MRI. The more experienced radiologist achieved higher accuracy with both HR-MRI and LR-MRI. The values of sensitivity, specificity, PPV, NPV, and accuracy did not significantly change between HR and LR images or interobserver agreement for all of the considered anatomic sites. LR-MRI performs as well as HR-MRI and is a valuable tool for the detection of deep endometriosis extension. (orig.)

  17. Comparison of low dose with standard dose abdominal/pelvic multidetector CT in patients with stage 1 testicular cancer under surveillance

    Energy Technology Data Exchange (ETDEWEB)

    O' Malley, Martin E. [Joint Department of Medical Imaging, Toronto, ON (Canada); Chung, Peter; Warde, Padraig [Princess Margaret Hospital, Department of Radiation Oncology, Toronto, ON (Canada); Haider, Masoom; Jhaveri, Kartik; Khalili, Korosh [Princess Margaret Hospital, Joint Department of Medical Imaging, Toronto, ON (Canada); Jang, Hyun-Jung [Toronto General Hospital, Joint Department of Medical Imaging, Toronto, ON (Canada); Panzarella, Tony [Princess Margaret Hospital, Department of Biostatistics, Toronto, ON (Canada)

    2010-07-15

    To compare the image quality and acceptability of a low dose with those of standard dose abdominal/pelvic multidetector CT in patients with stage 1 testicular cancer managed by surveillance. One hundred patients (median age 31 years; range 19-83 years), 79 with seminoma and 21 with non-seminoma, underwent abdominal/pelvic imaging with low and standard dose protocols on 64-slice multidetector CT. Three reviewers independently evaluated images for noise and diagnostic quality on a 5-point scale and for diagnostic acceptability. On average, each reader scored noise and diagnostic quality of standard dose images significantly better than corresponding low dose images (p < 0.0001). One reader found all CT examinations acceptable; two readers each found 1/100 (1%) low dose examinations unacceptable. Median and mean dose-length product for low and standard dose protocols were 416.0 and 452.2 (range 122.9-913.4) and 931.9 and 999.8 (range 283.8-1,987.7) mGy cm, respectively. The low dose protocol provided diagnostically acceptable images for at least 99% of patients and achieved mean dose reduction of 55% compared with the standard dose protocol. (orig.)

  18. Gastrointestinal toxicity of vorinostat: reanalysis of phase 1 study results with emphasis on dose-volume effects of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Bratland, Åse; Dueland, Svein; Hollywood, Donal; Flatmark, Kjersti; Ree, Anne H

    2011-01-01

    In early-phase studies with targeted therapeutics and radiotherapy, it may be difficult to decide whether an adverse event should be considered a dose-limiting toxicity (DLT) of the investigational systemic agent, as acute normal tissue toxicity is frequently encountered with radiation alone. We have reanalyzed the toxicity data from a recently conducted phase 1 study on vorinostat, a histone deacetylase inhibitor, in combination with pelvic palliative radiotherapy, with emphasis on the dose distribution within the irradiated bowel volume to the development of DLT. Of 14 eligible patients, three individuals experienced Common Terminology Criteria of Adverse Events grade 3 gastrointestinal and related toxicities, representing a toxicity profile vorinostat has in common with radiotherapy to pelvic target volumes. For each study patient, the relative volumes of small bowel receiving radiation doses between 6 Gy and 30 Gy at 6-Gy intervals (V6-V30) were determined from the treatment-planning computed tomography scans. The single patient that experienced a DLT at the second highest dose level of vorinostat, which was determined as the maximum-tolerated dose, had V6-V30 dose-volume estimates that were considerably higher than any other study patient. This patient may have experienced an adverse radiation dose-volume effect rather than a toxic effect of the investigational drug. When reporting early-phase trial results on the tolerability of a systemic targeted therapeutic used as potential radiosensitizing agent, radiation dose-volume effects should be quantified to enable full interpretation of the study toxicity profile.

  19. SU-F-P-55: Testicular Scatter Dose Determination During Prostate SBRT with and Without Pelvic Lymph Nodes

    Energy Technology Data Exchange (ETDEWEB)

    Venencia, C; Garrigo, E; Castro Pena, P; Torres, J; Zunino, S [Instituto de Radioterapia - Fundacion Marie Curie, Cordoba (Argentina); Germanier, A [Ceprocor, Cordoba (Argentina)

    2016-06-15

    Purpose: The elective irradiation of pelvis lymph node for prostate cancer is still controversial. Including pelvic lymph node as part of the planning target volume could increase the testicular scatter dose, which could have a clinical impact. The objective of this work was to measure testicular scatter dose for prostate SBRT treatment with and without pelvic lymph nodes using TLD dosimetry. Methods: A 6MV beam (1000UM/min) produce by a Novalis TX (BrainLAB-VARIAN) equipped HDMLC was used. Treatment plan were done using iPlan v4.5.3 (BrainLAB) treatment planning system with sliding windows IMRT technique. Prostate SBRT plan (PLAN-1) uses 9 beams with a dose prescription (D95%) of 4000cGy in 5 fractions. Prostate with lymph nodes SBRT plan (PLAN-2) uses 11 beams with a dose prescription (D95%) of 4000cGy to the prostate and 2500cGy to the lymph node in 5 fractions. An anthropomorphic pelvic phantom with a testicular volume was used. Phantom was positioned using ExacTrac IGRT system. Phosphor TLDs LiF:Mg, Ti (TLD700 Harshaw) were positioned in the anterior, posterior and inferior portion of the testicle. Two set of TLD measurements was done for each treatment plan. TLD in vivo dosimetry was done in one patient for each treatment plan. Results: The average phantom scatter doses per fraction for the PLAN-1 were 10.9±1cGy (anterior), 7.8±1cGy (inferior) and 10.7±1cGy (posterior) which represent an average total dose of 48±1cGy (1.2% of prostate dose prescription). The doses for PLAN-2 plan were 17.7±1cGy (anterior), 11±1cGy (inferior) and 13.3±1cGy (posterior) which represent an average total dose of 70.1±1cGy (1.8% of prostate dose prescription). The average dose for in vivo patient dosimetry was 60±1cGy for PLAN-1 and 85±1cGy for PLAN-2. Conclusion: Phantom and in vivo dosimetry shows that the pelvic lymph node irradiation with SBRT slightly increases the testicular scatter dose, which could have a clinical impact.

  20. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  1. Effects of Pelvic and Core Strength Training on High School Cross-Country Race Times.

    Science.gov (United States)

    Clark, Anne W; Goedeke, Maggie K; Cunningham, Saengchoy R; Rockwell, Derek E; Lehecka, Bryan J; Manske, Robert C; Smith, Barbara S

    2017-08-01

    Clark, AW, Goedeke, MK, Cunningham, SR, Rockwell, DE, Lehecka, BJ, Manske, RC, and Smith, BS. Effects of pelvic and core strength training on high school cross-country race times. J Strength Cond Res 31(8): 2289-2295, 2017-There is only limited research examining the effect of pelvic and core strength training on running performance. Pelvic and core muscle fatigue is believed to contribute to excess motion along frontal and transverse planes which decreases efficiency in normal sagittal plane running motions. The purpose of this study was to determine whether adding a 6-week pelvic and core strengthening program resulted in decreased race times in high school cross-country runners. Thirty-five high school cross-country runners (14-19 years old) from 2 high schools were randomly assigned to a strengthening group (experimental) or a nonstrengthening group (control). All participants completed 4 standardized isometric strength tests for hip abductors, adductors, extensors, and core musculature in a test-retest design. The experimental group performed a 6-week pelvic and core strengthening program along with their normal training. Participants in the control group performed their normal training without additional pelvic and core strengthening. Baseline, 3-week, and 6-week race times were collected using a repeated measures design. No significant interaction between experimental and control groups regarding decreasing race times and increasing pelvic and core musculature strength occurred over the 6-week study period. Both groups increased strength and decreased overall race times. Clinically significant findings reveal a 6-week pelvic and core stability strengthening program 3 times a week in addition to coach led team training may help decrease race times.

  2. Dose optimization in pelvic radiography by air gap method on CR and DR systems – A phantom study

    International Nuclear Information System (INIS)

    Chan, C.T.P.; Fung, K.K.L.

    2015-01-01

    Objectives: This study aimed at investigating the feasibility of replacing the anti-scatter grid with an air gap at a pelvic radiographic examination in order to reduce patient dose while retaining diagnostic image quality. Methods: An anthropomorphic pelvis phantom was placed on a device that allowed the adjustment of different air gap thicknesses introduced between the phantom and the image receptor of Computed Radiography (CR) and Digital Radiography (DR) systems. Grid and non-grid images with different air gap thicknesses of both systems were produced. Ovary and testes doses were measured using thermoluminescent dosimeters. Radiographic quality of all images was rated by 5 experienced radiographers blindly using the Image Quality Score (IQS) and Visual Grading Analysis (VGA) systems. Results: Images of diagnostic quality were produced while the grid was replaced by a range of 0–25 cm air gap thickness in the pelvic radiographic examination. At non-grid examination with 10 cm air gap thickness, a maximum of relative dose reduction by 70.7% and 81.6% at CR; 68.6% and 79.4% at DR were achieved respectively at ovary and testes locations of the phantom as compared with their corresponding grid examinations. Conclusion: 10 cm was found to be the optimal air gap thickness at the tested pelvic examination. Effective dose was found to be reduced by 2 and 2.3 times respectively at the CR and DR examinations while the anti-scatter grid was replaced by 10 cm air gap. However, dose reduction effect by air gap method was found to be more pronounced in CR than in DR. - Highlights: • 10 cm air gap was found to be a substitute to replace grid in pelvic RANDO in CR/DR. • Over 68.6% of dose reduction effect were achieved at the ovary and testes regions. • Over 76.4% of reduction in effective dose were achieved at both the tested regions. • Dose reduction by air gap method was found to be more pronounced in CR than in DR

  3. The role and strategy of IMRT in radiotherapy of pelvic tumors: Dose escalation and critical organ sparing in prostate cancer

    International Nuclear Information System (INIS)

    Liu, Y.-M.; Shiau, C.-Y.; Lee, M.-L.; Huang, P.-I.; Hsieh, C.-M.; Chen, P.-H.; Lin, Y.-H.; Wang, L.-W.; Yen, S.-H.

    2007-01-01

    Purpose: To investigate the intensity-modulated radiotherapy (IMRT) strategy in dose escalation of prostate and pelvic lymph nodes. Methods and Materials: Plan dosimetric data of 10 prostate cancer patients were compared with two-dimensional (2D) or IMRT techniques for pelvis (two-dimensional whole pelvic radiation therapy [2D-WPRT] or IM-WPRT) to receive 50 Gy or 54 Gy and additional prostate boost by three-dimensional conformal radiation therapy or IMRT (3D-PBRT or IM-PBRT) techniques up to 72 Gy or 78 Gy. Dose-volume histograms (DVHs), normal tissue complication probabilities (NTCP) of critical organ, and conformity of target volume in various combinations were calculated. Results: In DVH analysis, the plans with IM-WPRT (54 Gy) and additional boost up to 78 Gy had lower rectal and bladder volume percentage at 50 Gy and 60 Gy, compared with those with 2D-WPRT (50 Gy) and additional boost up to 72 Gy or 78 Gy. Those with IM-WPRT (54 Gy) also had better small bowel sparing at 30 Gy and 50 Gy, compared with those with 2D-WPRT (50 Gy). In NTCP, those with IM-WPRT and total dose of 78 Gy achieved lower complication rates in rectum and small bowel, compared with those of 2D-WPRT with total dose of 72 Gy. In conformity, those with IM-WPRT had better conformity compared with those with 2D-WPRT with significance (p < 0.005). No significant difference in DVHs, NTCP, or conformity was found between IM-PBRT and 3D-PBRT after IM-WPRT. Conclusions: Initial pelvic IMRT is the most important strategy in dose escalation and critical organ sparing. IM-WPRT is recommended for patients requiring WPRT. There is not much benefit for critical organ sparing by IMRT after 2D-WPRT

  4. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  5. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  6. Dose levels from thoracic and pelvic examinations in two pediatric radiological departments in Norway - a comparison study of dose-area product and radiographic technique

    International Nuclear Information System (INIS)

    Kjernlie Saether, Hilde; Traegde Martinsen, Anne Catrine; Lagesen, Bente; Platou Holsen, Eva; Oevreboe, Kirsti Marie

    2010-01-01

    Background: Pediatric doses expressed in dose-area product (DAP) can be retrieved from only a few publications; most of which correlate DAP to patient size or large age spans. In clinical practice age is often the only available parameter describing the patient, and thus, evaluation of dose levels in pediatric radiology on the basis of DAP related to age alone would be useful in optimization work. Purpose: To provide comparable data on age-related DAP from thoracic and pelvic radiological examinations of children, and evaluate the usefulness of comparing age-related DAP and radiographic technique between systems to identify areas with potential for optimization. Material and Methods: DAP, age, and radiographic technique were registered for 575 thoracic examinations and 371 pelvic examinations of children from newborn up to 14 years of age in groups with an age span of 1 year, performed with two digital flat-panel systems and one computed radiography system. Results: DAP varies from 2.2 to 54.0 mGycm2 for thoracic examinations, and from 4.6 to 532.5 mGycm2 for pelvic examinations. There are significant differences in DAP between systems and departments due to differences in technique, equipment, and staff. Conclusion: This study provides comparable data on age-related DAP from thoracic and pelvic radiological examinations of children, which could be used as an input to estimate diagnostic reference levels. The comparison between systems of DAP and radiographic technique has proven useful in identifying areas where there may be a potential for optimization.

  7. Gastrointestinal toxicity of vorinostat: reanalysis of phase 1 study results with emphasis on dose-volume effects of pelvic radiotherapy

    LENUS (Irish Health Repository)

    Bratland, Ase

    2011-04-08

    Abstract Background In early-phase studies with targeted therapeutics and radiotherapy, it may be difficult to decide whether an adverse event should be considered a dose-limiting toxicity (DLT) of the investigational systemic agent, as acute normal tissue toxicity is frequently encountered with radiation alone. We have reanalyzed the toxicity data from a recently conducted phase 1 study on vorinostat, a histone deacetylase inhibitor, in combination with pelvic palliative radiotherapy, with emphasis on the dose distribution within the irradiated bowel volume to the development of DLT. Findings Of 14 eligible patients, three individuals experienced Common Terminology Criteria of Adverse Events grade 3 gastrointestinal and related toxicities, representing a toxicity profile vorinostat has in common with radiotherapy to pelvic target volumes. For each study patient, the relative volumes of small bowel receiving radiation doses between 6 Gy and 30 Gy at 6-Gy intervals (V6-V30) were determined from the treatment-planning computed tomography scans. The single patient that experienced a DLT at the second highest dose level of vorinostat, which was determined as the maximum-tolerated dose, had V6-V30 dose-volume estimates that were considerably higher than any other study patient. This patient may have experienced an adverse radiation dose-volume effect rather than a toxic effect of the investigational drug. Conclusions When reporting early-phase trial results on the tolerability of a systemic targeted therapeutic used as potential radiosensitizing agent, radiation dose-volume effects should be quantified to enable full interpretation of the study toxicity profile. Trial registration ClinicalTrials.gov: NCT00455351

  8. Assessment of absorbed dose to the ovaries of patients undergoing pelvic CT examination

    Energy Technology Data Exchange (ETDEWEB)

    Tavakoli, H.M.B. [Isfahan Univ. of Medical Sciences (Iran, Islamic Republic of)

    2006-07-01

    Full text of publication follows: Introduction: Although Computed Tomography (CT) procedures constitute about 5% of the total diagnostic radiology procedures but are responsible for about 40% of the total ionizing radiation dose to the general population. As the dose is high especially in the CT of female pelvis, genetic radiation risk is also considerable. Materials and Methods: Radiation doses to the ovaries of the patients undergoing CT examination of the pelvis were measured from 9 different CT scanners available in Isfahan city. For each CT scanner 20 patients were selected. Measurement of organ dose was performed using TLD method. Results and Discussions: Mean and S.D. of absorbed dose to the ovaries from Shimadzo 2500 were 56.6 2.8; from GE Max 640 were 36.8 1.7; from GE Sytec 3000 were 36.6 1.8; from GE Sytec 4000 were 36.6 2.6; from Piker were 38.4 2.1; from Shimadzo 4500 were 36.4 1.2 and from Shimadzo 7800TE 28.2 1.5. Associated risks due to the measured dose are discussed. (author)

  9. Patient-related factors determining geometry of intracavitary applicators and pelvic dose distribution during cervical cancer brachytherapy

    International Nuclear Information System (INIS)

    Senkus-Konefka, Elzbieta; Kobierska, Anna; Jassem, Jacek; Badzio, Andrezej

    1997-01-01

    Purpose: The aim of this study was to assess retrospectively the influence of the size of cervical cancer brachytherapy applicators (ovoids and uterine tandems) on pelvic dose distribution and to analyze the impact of various patient-and disease-related factors on applicators' geometry and on dose distribution in particular applications. Methods and Materials: The subject of this study were 356 cervical cancer patients treated with Selectron LDR as a part of their radical radiotherapy. Analyzed factors included patient age, weight, number of vaginal deliveries, and disease stage. Results: The use of larger vaginal applicators resulted in lower bladder and rectum doses and in higher point B doses (all p < 0.0001); longer uterine tandems produced lower rectum doses and higher point B doses (both p < 0.0001). Increasing patient age and disease stage resulted in a decreased frequency of use of large ovoids (both p < 0.0001) and of long tandems (age: p = 0.0069, stage: p = 0.004). As a result, higher doses to bladder (age: p < 0.0001, stage: p = 0.017) and rectum (age: p = 0.037, stage: p = 0.011) were observed. Increasing age also resulted in lower point B doses (p < 0.0001). Increasing patient weight correlated with less frequent use of long tandems (p = 0.0015) and with higher bladder doses (p = 0.04). Higher number of vaginal deliveries was related to the increase in the use of long tandems (p = 0.002); in patients who had had at least one vaginal delivery, point B doses were significantly higher (p = 0.0059). In multivariate analysis ovoid size and uterine tandem length were dependent on patient age (respectively: p < 0.001 and p = 0.001), disease stage (respectively: p = 0.003 and p = 0.008) and on the number of vaginal deliveries (respectively: p = 0.07 and p 0.008). Doses to critical organs and to points B were dependent on patient age (respectively: p < 0.001, p = 0.011, and p < 0.001) and on disease stage (respectively: p < 0.001, p = 0.004, and p = 0

  10. Dose-Volume Relationships for Acute Bowel Toxicity in Patients Treated With Pelvic Nodal Irradiation for Prostate Cancer

    International Nuclear Information System (INIS)

    Fiorino, Claudio; Alongi, Filippo; Perna, Lucia; Broggi, Sara; Cattaneo, Giovanni Mauro; Cozzarini, Cesare; Di Muzio, Nadia; Fazio, Ferruccio; Calandrino, Riccardo

    2009-01-01

    Purpose: To find correlation between dose-volume histograms (DVHs) of the intestinal cavity (IC) and moderate-severe acute bowel toxicity in men with prostate cancer treated with pelvic nodal irradiation. Methods and Materials: The study group consisted of 191 patients with localized prostate cancer who underwent whole-pelvis radiotherapy with radical or adjuvant/salvage intent during January 2004 to November 2007. Complete planning/clinical data were available in 175 of these men, 91 of whom were treated with a conventional four-field technique (50.4 Gy, 1.8 Gy/fraction) and 84 of whom were treated with IMRT using conventional Linac (n = 26, 50.4 Gy, 1.8 Gy/fraction) or Helical TomoTherapy (n = 58, 50-54 Gy, 1.8-2 Gy/fraction). The IC outside the planning target volume (PTV) was contoured and the DVH for the first 6 weeks of treatment was recovered in all patients. The correlation between a number of clinical and DVH (V10-V55) variables and toxicity was investigated in univariate and multivariate analyses. The correlation between DVHs for the IC outside the PTV and DVHs for the whole IC was also assessed. Results: Twenty-two patients experienced toxicity (3/22 in the IMRT/tomotherapy group). Univariate analyses showed a significant correlation between V20-V50 and toxicity (p = 0.0002-0.001), with a higher predictive value observed for V40-V50. Previous prostatectomy (p = 0.066) and abdominal/pelvic surgery (p = 0.12) also correlated with toxicity. Multivariate analysis that included V45, abdominal/pelvic surgery, and prostatectomy showed that the most predictive parameters were V45 (p = 0.002) and abdominal/pelvic surgery (p = 0.05, HR = 2.4) Conclusions: Our avoidance IMRT approach drastically reduces the incidence of acute bowel toxicity. V40-V50 of IC and, secondarily, previous abdominal/pelvic surgery were the main predictors of acute bowel toxicity.

  11. Treatment of Chronic Refractory Neuropathic Pelvic Pain with High-Frequency 10-kilohertz Spinal Cord Stimulation.

    Science.gov (United States)

    Simopoulos, Thomas; Yong, Robert J; Gill, Jatinder S

    2017-11-06

    Chronic neuropathic pelvic pain remains a recalcitrant problem in the field of pain management. Case series on application of 10 kHz spinal cord stimulation is presented. High frequency stimulation can improve chronic neuropathic pain states that are known to be mediated at the conus medullaris and offers another avenue for the treatment of these patients. © 2017 World Institute of Pain.

  12. Evaluation of build-up dose from 6 MV X-rays under pelvic and abdominal patient immobilisation devices

    Energy Technology Data Exchange (ETDEWEB)

    Cheung Tsang; Butson, M.J.Martin J. E-mail: mbutson@usa.netmbutson@guessmail.com; Yu, P.K.N

    2002-06-01

    The use of pelvic and abdominal immobilisation devices in radiotherapy is required for accurate positioning and repositioning of patients during their fractionated treatment delivered normally over a period of 5-6 weeks. 6 MV X-rays produced by a medical linear accelerator have a skin sparing effect whereby the skin dose delivered is considerably less than that received by the tumour. The treatment through a vacuum compressed immobilisation device (Vacbag) however increases the dose delivered to the skin by interactions of the X-rays within the Vacbag material. For example, the basal layer doses increased from 16% for an open field to 52% of maximum with a bag thickness of 2.5 cm for a 10 cmx10 cm field at 6 MV X-ray energy. At the same field size the dermal skin layer (1 mm depth) doses increased from 44% (no bag) to 60% for a bag thickness of 2.5 cm at 6 MV X-rays. The Vacbag should be placed outside the treatment field whenever possible to keep skin dose to a minimum level.

  13. Evaluation of build-up dose from 6 MV X-rays under pelvic and abdominal patient immobilisation devices

    International Nuclear Information System (INIS)

    Cheung Tsang; Butson, M.J.Martin J.; Yu, P.K.N.

    2002-01-01

    The use of pelvic and abdominal immobilisation devices in radiotherapy is required for accurate positioning and repositioning of patients during their fractionated treatment delivered normally over a period of 5-6 weeks. 6 MV X-rays produced by a medical linear accelerator have a skin sparing effect whereby the skin dose delivered is considerably less than that received by the tumour. The treatment through a vacuum compressed immobilisation device (Vacbag) however increases the dose delivered to the skin by interactions of the X-rays within the Vacbag material. For example, the basal layer doses increased from 16% for an open field to 52% of maximum with a bag thickness of 2.5 cm for a 10 cmx10 cm field at 6 MV X-ray energy. At the same field size the dermal skin layer (1 mm depth) doses increased from 44% (no bag) to 60% for a bag thickness of 2.5 cm at 6 MV X-rays. The Vacbag should be placed outside the treatment field whenever possible to keep skin dose to a minimum level

  14. Whole-Pelvic Nodal Radiation Therapy in the Context of Hypofractionation for High-Risk Prostate Cancer Patients: A Step Forward

    International Nuclear Information System (INIS)

    Kaidar-Person, Orit; Roach, Mack; Créhange, Gilles

    2013-01-01

    Given the low α/β ratio of prostate cancer, prostate hypofractionation has been tested through numerous clinical studies. There is a growing body of literature suggesting that with high conformal radiation therapy and even with more sophisticated radiation techniques, such as high-dose-rate brachytherapy or image-guided intensity modulated radiation therapy, morbidity associated with shortening overall treatment time with higher doses per fraction remains low when compared with protracted conventional radiation therapy to the prostate only. In high-risk prostate cancer patients, there is accumulating evidence that either dose escalation to the prostate or hypofractionation may improve outcome. Nevertheless, selected patients who have a high risk of lymph node involvement may benefit from whole-pelvic radiation therapy (WPRT). Although combining WPRT with hypofractionated prostate radiation therapy is feasible, it remains investigational. By combining modern advances in radiation oncology (high-dose-rate prostate brachytherapy, intensity modulated radiation therapy with an improved image guidance for soft-tissue sparing), it is hypothesized that WPRT could take advantage of recent results from hypofractionation trials. Moreover, the results from hypofractionation trials raise questions as to whether hypofractionation to pelvic lymph nodes with a high risk of occult involvement might improve the outcomes in WPRT. Although investigational, this review discusses the challenging idea of WPRT in the context of hypofractionation for patients with high-risk prostate cancer

  15. Whole-Pelvic Nodal Radiation Therapy in the Context of Hypofractionation for High-Risk Prostate Cancer Patients: A Step Forward

    Energy Technology Data Exchange (ETDEWEB)

    Kaidar-Person, Orit [Division of Oncology, Rambam Health Care Campus, Haifa (Israel); Roach, Mack [Department of Radiation Oncology, University of California, San Francisco, San Francisco, California (United States); Créhange, Gilles, E-mail: gcrehange@cgfl.fr [Department of Radiation Oncology, Georges-François Leclerc Cancer Center, Dijon (France)

    2013-07-15

    Given the low α/β ratio of prostate cancer, prostate hypofractionation has been tested through numerous clinical studies. There is a growing body of literature suggesting that with high conformal radiation therapy and even with more sophisticated radiation techniques, such as high-dose-rate brachytherapy or image-guided intensity modulated radiation therapy, morbidity associated with shortening overall treatment time with higher doses per fraction remains low when compared with protracted conventional radiation therapy to the prostate only. In high-risk prostate cancer patients, there is accumulating evidence that either dose escalation to the prostate or hypofractionation may improve outcome. Nevertheless, selected patients who have a high risk of lymph node involvement may benefit from whole-pelvic radiation therapy (WPRT). Although combining WPRT with hypofractionated prostate radiation therapy is feasible, it remains investigational. By combining modern advances in radiation oncology (high-dose-rate prostate brachytherapy, intensity modulated radiation therapy with an improved image guidance for soft-tissue sparing), it is hypothesized that WPRT could take advantage of recent results from hypofractionation trials. Moreover, the results from hypofractionation trials raise questions as to whether hypofractionation to pelvic lymph nodes with a high risk of occult involvement might improve the outcomes in WPRT. Although investigational, this review discusses the challenging idea of WPRT in the context of hypofractionation for patients with high-risk prostate cancer.

  16. Dose perturbation due to the presence of a prostatic urethral stent in patients receiving pelvic radiotherapy: an in vitro study.

    Science.gov (United States)

    Gez, E; Cederbaum, M; Yachia, D; Bar-Deroma, R; Kuten, A

    1997-01-01

    Temporary metallic intraprostatic stent is a new alternative treatment for patients with urinary obstructive syndrome caused by prostate cancer. Definitive radiotherapy is a treatment of choice for localized prostate cancer. This study evaluates in vitro the effect of a urethral intraprostatic metallic stent on the dose absorbed by the surrounding tissue. The study was designed to mimic the conditions under which the prostatic stent is placed in the body during pelvic irradiation. A urethral stent composed of a 50% nickel-50% titanium alloy (Uracoil-InStent) was imbedded in material mimicking normal tissue (bolus) at a simulated body depth of 10 cm. The distribution of the absorbed dose of irradiation was determined by film dosimetry using Kodak X-Omat V film. Irradiation was done in a single field at the isocenter of a 6 MV linear accelerator with a field size of 7 x 7 cm. The degree of film blackening was in direct proportion to the absorbed dose. The measurements showed an increase in dose of up to 20% immediately before the stent and a decrease of up to 18% immediately after the stent. These changes occurred within a range of 1-3 mm from both sides of the stent. In practice, irradiation in prostate cancer is given by two pairs of opposed co-axial fields; a total of four fields (Box Technique). The dose perturbations are partly cancelled in a pair of opposed beams resulting in a net variation of +/- 4%; therefore, the presence of the intraprostatic stent should not influence radiotherapy planning for prostate cancer.

  17. Modified Thiele massage as therapeutic intervention for female patients with interstitial cystitis and high-tone pelvic floor dysfunction.

    Science.gov (United States)

    Oyama, Ian A; Rejba, Amy; Lukban, James C; Fletcher, Erica; Kellogg-Spadt, Susan; Holzberg, Adam S; Whitmore, Kristene E

    2004-11-01

    To evaluate the effectiveness of transvaginal manual therapy of the pelvic floor musculature (Thiele massage) in symptomatic female patients with interstitial cystitis and high-tone dysfunction of the pelvic floor. A total of 21 women with documented interstitial cystitis and high-tone pelvic floor dysfunction underwent transvaginal massage using the Thiele technique twice a week for 5 weeks. Symptoms were evaluated before massage, at protocol conclusion, and at a mean of 4.5 months after therapy completion (long-term follow-up). The response to treatment was evaluated through the O'Leary-Sant Interstitial Cystitis Symptom and Problem Indexes, Likert Visual Analogue Scales for urgency and pain, and Short-Form 12-item (SF-12) Quality-of-Life Scale, and through changes in the physical examination findings using a 5-point modified Oxford Scale to document pelvic floor tenderness. A statistically significant improvement was seen in the Symptom and Problem Indexes of the O'Leary-Sant Questionnaire (P = 0.015 and P = 0.039, respectively), Likert Visual Analogue Scales for urgency and pain (P = 0.001 and P = 0.005, respectively), the Physical and Mental Component Summary from the SF-12 Quality-of-Life Scale (P = 0.049 and P = 0.044, respectively), and the modified Oxford Scale (P pelvic floor (P pelvic floor dysfunction in addition to decreasing pelvic floor muscle tone.

  18. Impact of Bone Marrow Radiation Dose on Acute Hematologic Toxicity in Cervical Cancer: Principal Component Analysis on High Dimensional Data

    International Nuclear Information System (INIS)

    Yun Liang; Messer, Karen; Rose, Brent S.; Lewis, John H.; Jiang, Steve B.; Yashar, Catheryn M.; Mundt, Arno J.; Mell, Loren K.

    2010-01-01

    Purpose: To study the effects of increasing pelvic bone marrow (BM) radiation dose on acute hematologic toxicity in patients undergoing chemoradiotherapy, using a novel modeling approach to preserve the local spatial dose information. Methods and Materials: The study included 37 cervical cancer patients treated with concurrent weekly cisplatin and pelvic radiation therapy. The white blood cell count nadir during treatment was used as the indicator for acute hematologic toxicity. Pelvic BM radiation dose distributions were standardized across patients by registering the pelvic BM volumes to a common template, followed by dose remapping using deformable image registration, resulting in a dose array. Principal component (PC) analysis was applied to the dose array, and the significant eigenvectors were identified by linear regression on the PCs. The coefficients for PC regression and significant eigenvectors were represented in three dimensions to identify critical BM subregions where dose accumulation is associated with hematologic toxicity. Results: We identified five PCs associated with acute hematologic toxicity. PC analysis regression modeling explained a high proportion of the variation in acute hematologicity (adjusted R 2 , 0.49). Three-dimensional rendering of a linear combination of the significant eigenvectors revealed patterns consistent with anatomical distributions of hematopoietically active BM. Conclusions: We have developed a novel approach that preserves spatial dose information to model effects of radiation dose on toxicity, which may be useful in optimizing radiation techniques to avoid critical subregions of normal tissues. Further validation of this approach in a large cohort is ongoing.

  19. Optimisation of CT procedures by dose reduction in abdominal-pelvic studies of chronic patients

    International Nuclear Information System (INIS)

    Calvo, D.; Rodriguez, A.M.; Peinado, M.A.; Fernandez, B.; Fernandez, B.M.; Jimenez, J.R.

    2006-01-01

    Full text of publication follows: Objectives: CT explorations are responsible of a significant increase of collective dose during last twenty years. However, by adapting the procedures to the specific diagnostic requirements of each kind of exploration, dose values can be decreased. This can be specially interesting for chronic patients who undergo several CT controls. The aim of this research is to contrast CT image diagnostic quality by comparing those techniques commonly used in our hospital with lower dose ones. Materials and methods: In a first phase, a study on phantom has been developed to evaluate image quality variations obtained with standard a several low dose techniques. Dose reduction was quantified as well by means of C.T.D.I. w measurements on an abdominal phantom. Both aspects were taken into account to determine a dose threshold below image quality degradation was considered unacceptable from a diagnostic point of view. Subsequently, a group of 50 chronic patients under follow -up was selected to undergo a control CT but with a low dose-technique. Image diagnostic quality was compared with that of previous controls obtained using the standard technique. Three experimented radiologist carried out this evaluation over a sample of six particular slices located at the abdomen and pelvis using an ordinal scale. Such a scale gradate the confidence level of the image for each radiologist. This evaluation was repeated one and two months later without knowledge of previous results to calculate inter and intra -observer variability. Conclusions: CT studies can be carried out with a significant dose reduction preserving their diagnostic capabilities. A quantitative evaluation will be offered at the end of the study, still running. (authors)

  20. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  1. Botulinum Toxin A Injections Into Pelvic Floor Muscles Under Electromyographic Guidance for Women With Refractory High-Tone Pelvic Floor Dysfunction: A 6-Month Prospective Pilot Study.

    Science.gov (United States)

    Morrissey, Darlene; El-Khawand, Dominique; Ginzburg, Natasha; Wehbe, Salim; O'Hare, Peter; Whitmore, Kristene

    2015-01-01

    High-tone pelvic floor dysfunction (HTPFD) is a debilitating chronic pain disorder for many women with significant impact on their quality of life (QoL). Our objective was to determine the efficacy of electromyography-guided onabotulinumtoxinA (Botox; Allergan, Irvine, Calif) injections in treating patient's perception of pelvic pain and improving QoL measurement scores. This is a prospective pilot open-label study of women with chronic pelvic pain and HTPFD who have failed conventional therapy between January 2011 and August 2013. Botox injections (up to 300 U) were done using needle electromyography guidance, from a transperineal approach, to localize spastic pelvic floor muscles (PFMs). Data were collected at baseline, 4, 8, 12, and 24 weeks after injections. This included demographics; Visual Analog Scale (VAS) scores for pain and dyspareunia; validated questionnaires for symptoms, QoL, and sexual function; Global Response Assessment scale for pelvic pain; digital examination of PFM for tone and tenderness; and vaginal manometry. Side effects were also recorded. Out of 28 women who enrolled in the study, 21 completed the 6-month follow-up and qualified for analysis. The mean (SD) age was 35.1 (9.4) years (range, 22-50 years), and the mean (SD) body mass index was 25 (4.4). Comorbidities included interstitial cystitis/bladder pain syndrome (42.9%) and vulvodynia (66.7%). Overall, 61.9% of subjects reported improvement on Global Response Assessment at 4 weeks and 80.9% at 8, 12, and 24 weeks post injection, compared with baseline. Of the subjects who were sexually active at baseline, 58.8% (10/17), 68.8% (11/16), 80% (12/15), and 83.3% (15/18) reported less dyspareunia at 4, 8, 12, and 24 weeks, respectively. Dyspareunia Visual Analog Scale score significantly improved at weeks 12 (5.6, P = 0.011) and 24 (5.4, P = 0.004) compared with baseline (7.8). Two of the 4 patients who avoided sexual activity at baseline secondary to dyspareunia resumed and tolerated

  2. Nodal Clearance Rate and Long-Term Efficacy of Individualized Sentinel Node–Based Pelvic Intensity Modulated Radiation Therapy for High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Müller, Arndt-Christian, E-mail: arndt-christian.mueller@med.uni-tuebingen.de [Department of Radiation Oncology, Eberhard Karls University, Tübingen (Germany); Eckert, Franziska; Paulsen, Frank; Zips, Daniel [Department of Radiation Oncology, Eberhard Karls University, Tübingen (Germany); Stenzl, Arnulf; Schilling, David [Department of Urology, Eberhard Karls University, Tübingen (Germany); Alber, Markus [Department of Oncology, Aarhus University, Aarhus (Denmark); Bares, Roland [Department of Nuclear Medicine and Clinical Molecular Imaging, Eberhard Karls University, Tübingen (Germany); Martus, Peter [Institute for Clinical Epidemiology and Applied Biometry, Eberhard Karls University, Tübingen (Germany); Weckermann, Dorothea [Department of Urology, Klinikum Augsburg, Augsburg (Germany); Belka, Claus; Ganswindt, Ute [Department of Radiation Oncology, Ludwig-Maximilians-University, Munich (Germany)

    2016-02-01

    Purpose: To assess the efficacy of individual sentinel node (SN)-guided pelvic intensity modulated radiation therapy (IMRT) by determining nodal clearance rate [(n expected nodal involvement − n observed regional recurrences)/n expected nodal involvement] in comparison with surgically staged patients. Methods and Materials: Data on 475 high-risk prostate cancer patients were examined. Sixty-one consecutive patients received pelvic SN-based IMRT (5 × 1.8 Gy/wk to 50.4 Gy [pelvic nodes + individual SN] and an integrated boost with 5 × 2.0 Gy/wk to 70.0 Gy to prostate + [base of] seminal vesicles) and neo-/adjuvant long-term androgen deprivation therapy; 414 patients after SN–pelvic lymph node dissection were used to calculate the expected nodal involvement rate for the radiation therapy sample. Biochemical control and overall survival were estimated for the SN-IMRT patients using the Kaplan-Meier method. The expected frequency of nodal involvement in the radiation therapy group was estimated by imputing frequencies of node-positive patients in the surgical sample to the pattern of Gleason, prostate-specific antigen, and T category in the radiation therapy sample. Results: After a median follow-up of 61 months, 5-year OS after SN-guided IMRT reached 84.4%. Biochemical control according to the Phoenix definition was 73.8%. The nodal clearance rate of SN-IMRT reached 94%. Retrospective follow-up evaluation is the main limitation. Conclusions: Radiation treatment of pelvic nodes individualized by inclusion of SNs is an effective regional treatment modality in high-risk prostate cancer patients. The pattern of relapse indicates that the SN-based target volume concept correctly covers individual pelvic nodes. Thus, this SN-based approach justifies further evaluation, including current dose-escalation strategies to the prostate in a larger prospective series.

  3. Pharmacokinetically guided dosing of (high-dose) chemotherapeutic agents

    NARCIS (Netherlands)

    Attema-de Jonge, M.E. (Milly Ellen)

    2004-01-01

    Due to variation in drug distribution, metabolism and elimination processes between patients, systemic exposure to chemotherapeutic agents may be highly variable from patient to patient after administration of similar doses. This pharmacokinetic variability may explain in part the large variability

  4. Influence of hamstring muscles extensibility on spinal curvatures and pelvic tilt in highly trained cyclists.

    Science.gov (United States)

    Muyor, José M; Alacid, Fernando; López-Miñarro, Pedro A

    2011-09-01

    The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR hamstring extensibility group (PSLR = 80º - 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles.

  5. Fiber optics in high dose radiation fields

    International Nuclear Information System (INIS)

    Partin, J.K.

    1985-01-01

    A review of the behavior of state-of-the-art optical fiber waveguides in high dose (greater than or equal to 10 5 rad), steady state radiation fields is presented. The influence on radiation-induced transmission loss due to experimental parameters such as dose rate, total dose, irradiation history, temperature, wavelength, and light intensity, for future work in high dose environments are given

  6. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  7. Classification of high-grade spondylolistheses based on pelvic version and spine balance: possible rationale for reduction.

    Science.gov (United States)

    Hresko, Michael T; Labelle, Hubert; Roussouly, Pierre; Berthonnaud, Eric

    2007-09-15

    Retrospective review of a radiographic database of high-grade spondylolisthesis patients in comparison with asymptomatic controls. To analyze the sagittal spinopelvic alignment in high-grade spondylolisthesis patients and identify subgroups that may require reduction to restore sagittal balance. High-grade spondylolisthesis is associated with an abnormally high pelvic incidence (PI); however, the spatial orientation of the pelvis, determined by sacral slope (SS) and pelvic tilt (PT), is not known. We hypothesized that sagittal spinal alignment would vary with the pelvic orientation. Digitized sagittal radiographs of 133 high-grade spondylolisthesis patients (mean age, 17 years) were measured to determined sagittal alignment. K-means cluster analysis identified 2 groups based on the PT and SS, which were compared by paired t test. Comparisons were made to asymptomatic controls matched for PI. High-grade spondylolisthesis patients had a mean PI of 78.9 degrees +/- 12.1 degrees . Cluster analysis identified a retroverted, unbalanced pelvis group with high PT (36.5 degrees +/- 8.0 degrees )/low SS (40.3 degrees +/- 9.0 degrees ) and a balanced pelvic group with low PT (mean 21.3 degrees +/- 8.2 degrees )/high SS (59.9 degrees +/- 11.2 degrees ). The retroverted pelvis group had significantly greater L5 incidence and lumbosacral angle with less thoracic kyphosis than the balanced pelvic group. A total of 83% of controls had a "balanced pelvis" based on the categorization by SS and PT. Analysis of sagittal alignment of high-grade spondylolisthesis patients revealed distinct groups termed "balanced" and "unbalanced" pelvis. The PT and SS were similar in controls and balanced pelvis patients. Unbalanced pelvis patients had a sagittal spinal alignment that differed from the balanced pelvis and control groups. Treatment strategies for high-grade spondylolisthesis should reflect the different mechanical strain on the spinopelvic junction in each group; reduction techniques

  8. Local diagnostic reference level based on size-specific dose estimates: Assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children's hospital

    Energy Technology Data Exchange (ETDEWEB)

    Imai, Rumi; Miyazaki, Osamu; Kurosawa, Hideo; Nosaka, Shunsuke [National Center for Child Health and Development, Department of Radiology, Setagaya-ku, Tokyo (Japan); Horiuchi, Tetsuya [Osaka University, Department of Medical Physics and Engineering, Division of Medical Technology and Science, Course of Health Science, Graduate School of Medicine, Suita, Osaka (Japan)

    2015-03-01

    A child's body size is not accurately reflected by volume CT dose index (CTDI{sub vol}) and dose-length product (DLP). Size-specific dose estimation (SSDE) was introduced recently as a new index of radiation dose. However, it has not yet been established as a diagnostic reference level (DRL). To calculate the SSDE of abdominal/pelvic CT and compare the SSDE with CTDI{sub vol}. To calculate the DRLs of CTDI{sub vol} and SSDE. Our hypotheses are: SSDE values will be greater than CTDI{sub vol}, and our DRL will be smaller than the known DRLs of other countries. The CTDI{sub vol} and DLP of 117 children who underwent abdominal/pelvic CT were collected retrospectively. The SSDE was calculated from the sum of the lateral and anteroposterior diameters. The relationships between body weight and effective diameter and between effective diameter and CTDI{sub vol}/SSDE were compared. Further, the local DRL was compared with the DRLs of other countries. Body weight and effective diameter and effective diameter and SSDE were positively correlated. In children ages 1, 5 and 10 years, the SSDE is closer to the exposure dose of CTDI{sub vol} for the 16-cm phantom, while in children ages 15 years, the SSDE falls between CTDI{sub vol} for the 16-cm phantom and that for the 32-cm phantom. The local DRL was lower than those of other countries. With SSDE, the radiation dose increased with increasing body weight. Since SSDE takes body size into account, it proved to be a useful indicator for estimating the exposure dose. (orig.)

  9. HIGH-DOSE RATE BRACHYTHERAPY IN CARCINOMA CERVIX STAGE IIIB

    Directory of Open Access Journals (Sweden)

    Sathya Maruthavanan

    2016-07-01

    Full Text Available INTRODUCTION Radiotherapy is the standard treatment in locally advanced (IIB-IVA and early inoperable cases. The current standard of practice with curable intent is concurrent chemoradiation in which intracavitary brachytherapy is an integral component of radiotherapy. This study aims at assessing the efficacy of HDR ICBT (High-dose rate intracavitary brachytherapy in terms local response, normal tissue reactions, and feasibility. METHODS AND MATERIALS A total of 20 patients of stage IIIB cancer of the uterine cervix were enrolled in the study and were planned to receive concurrent chemotherapy weekly along with EBRT (external beam radiotherapy to a dose of 50 Gy/25 Fr. Suitability for ICBT was assessed at 40 Gy/20 Fr. 6/20 patients were suitable at 40 Gy and received HDR ICBT with a dose of 5.5 Gy to point A in 4 sessions (5.5 Gy/4 Fr. The remaining 14/20 patients completed 50 Gy and received HDR ICBT with a dose of 6 Gy to point A in 3 sessions (6 Gy/3 Fr. RESULTS A total of 66 intracavitary applications were done and only one application required dose modification due to high bladder dose, the pelvic control rate was 85% (17/20. 10% (2/20 had stable disease and 5% (1/20 had progressive disease at one year of follow up. When toxicity was considered only 15% developed grade I and grade II rectal complications. Patient compliance and acceptability was 100%. Patients were very comfortable with the short treatment time as compared with patients on LDR ICBT (low-dose rate intracavitary brachytherapy treatment interviewed during the same period. CONCLUSION This study proves that HDR brachytherapy is efficacious and feasible in carcinoma of cervix stage IIIB. It also proves that good dose distribution can be achieved with HDR intracavitary facility by the use of dose optimization. The short treatment time in HDR ICBT makes it possible to maintain this optimised dose distribution throughout the treatment providing a gain in the therapeutic ratio and

  10. Exercise level before pregnancy and engaging in high-impact sports reduce the risk of pelvic girdle pain: a population-based cohort study of 39 184 women.

    Science.gov (United States)

    Owe, Katrine Mari; Bjelland, Elisabeth K; Stuge, Britt; Orsini, Nicola; Eberhard-Gran, Malin; Vangen, Siri

    2016-07-01

    To examine whether an association exists between exercise levels pre-pregnancy and pelvic girdle pain in pregnancy. Pelvic girdle pain in pregnancy has been associated with physical inactivity, a risk factor for adverse pregnancy outcomes. We used data from a population-based cohort study including 39 184 nulliparous women with a singleton pregnancy enrolled in the Norwegian Mother and Child Cohort study. Pre-pregnancy exercise frequency and types were assessed by questionnaire in pregnancy week 17. Pelvic girdle pain, defined as combined pain in the anterior pelvis and in the posterior pelvis bilaterally, was self-reported in pregnancy week 30. Multivariable Poisson regression estimated risks of pelvic girdle pain associated with pre-pregnancy exercise. We examined a dose-response association of prepregnancy exercise frequency using restricted cubic splines. A test for non-linearity was also conducted. Final models were adjusted for pre-pregnancy BMI, age, education, history of low back pain and history of depression. 4069 women (10.4%) reported pelvic girdle pain in pregnancy and the prevalence among women who were non-exercisers prepregnancy was 12.5%. There was a non-linear association for pre-pregnancy exercise and risk of pelvic girdle pain (test for non-linearity, p=0.003). Compared to non-exercisers, women exercising 3-5 times weekly pre-pregnancy had a 14% lower risk of developing pelvic girdle pain in pregnancy (aRR 0.86, 95% CI 0.77 to 0.96). Taking part in high-impact exercises such as running, jogging, orienteering, ballgames, netball games and high-impact aerobics were associated with less risk of pelvic girdle pain. Women who exercise regularly and engage in high-impact exercises before the first pregnancy may have a reduced risk of pelvic girdle pain in pregnancy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. Progress in high-dose radiation dosimetry

    International Nuclear Information System (INIS)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.; Chadwick, K.H.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expanded applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Reference systems also include a number of chemical dose meters: ferrous sulphate, ferrous-cupric sulphate, and ceric sulphate acidic aqueous solutions. Requirements for stable and reliable transfer dose meters have led to further developments of several important high-dose systems: amino acids and saccharides analysed by ESR or lyoluminescence, thermoluminescent materials, radiochromic dyes and plastics, ceric-cerous solutions analysed by potentiometry, and ethanol-chlorobenzene solutions analysed by high-frequency oscillometry. A number of other prospective dose meters are also treated in this review. In addition, an IAEA programme of high-dose standardization and intercomparison for industrial radiation processing is described. (author)

  12. INFECTION AFTER RADICAL ABDOMINAL HYSTERECTOMY AND PELVIC LYMPHADENECTOMY - PREVENTION OF INFECTION WITH A 2-DOSE PERIOPERATIVE ANTIBIOTIC-PROPHYLAXIS

    NARCIS (Netherlands)

    BOUMA, J

    1993-01-01

    Surgical site-related infections occurred in 21% of 87 consecutive patients undergoing radical hysterectomy with pelvic lymphadenectomy (RHPL) without planned peri-operative prophylaxis. A prospective, randomized double-blind, placebo-controlled study was conducted in 68 consecutive RHPL patients.

  13. Fluorouracil and high-dose leucovorin with radiotherapy as adjuvant therapy for rectal cancer. Results of a phase II study

    Energy Technology Data Exchange (ETDEWEB)

    Giralt, J. [Radiation Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Rubio, D. [Medical Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Maldonado, X. [Radiation Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Naval, J. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Casado, S. [Medical Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Lara, F. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Rosello, J.M. [Dept. of Preventive Medicine, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Armengol, M. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain)

    1997-07-01

    The purpose of this phase II study was to evaluate the efficacy and toxicity of fluorouracil and high-dose leucovorin (5-FU/LV) with pelvic irradiation as adjuvant therapy for patients with macroscopical resected rectal or recto-sigmoid cancer. Following surgery for stages II-III primary (52) or recurrent rectal cancer (4), 56 patients received 8 cycles of 5-FU/LV and pelvic irradiation. 5-FU doses were 200 mgr/m{sup 2} for cycles 2-3 and 300 mgr/m{sup 2} for cycles 1 and 4-8. LV doses remained fixed at 200 mgr/m{sup 2}. Pelvic radiation was started in the third week, between the first and second cycle. The total dose was 50.4 Gy. No serve complications had been recorded. The incidence of grade 3 diarrhea was 19%. Three patients presented leukopenia grade 3 (5%). In 44 patients (78%) the planned treatment could be administered. The median follow-up was 40 months (range 22-66). Seven patients had a local relapse (13%) and 6 developed distant metastasis (10%). The 3-year disease-free survival was 72% and the overall survival was 76%. These preliminary results show that combined post-operative 5-FU/LV and pelvic radiotherapy are well tolerated and present a reasonable local control and survival rates. This adjuvant treatment should be evaluated in randomized trials. (orig.).

  14. High-dose irradiation of food

    International Nuclear Information System (INIS)

    Diehl, J.F.

    1999-01-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [de

  15. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    International Nuclear Information System (INIS)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-01-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  16. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, David, E-mail: d-pasquier@o-lambret.fr [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Centre Galilee, Clinique de la Louviere, Lille (France); Cavillon, Fabrice [Universite Lille Nord de France, Lille (France); Faculte Libre de Medecine, Lille (France); Lacornerie, Thomas [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Touzeau, Claire [Centre Galilee, Clinique de la Louviere, Lille (France); Tresch, Emmanuelle [Unite de Methodologie et Biostatistique, Centre O. Lambret, Lille (France); Lartigau, Eric [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France)

    2013-02-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  17. A dosimetric comparison of tomotherapy and volumetric modulated arc therapy in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy.

    Science.gov (United States)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-02-01

    To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. High spatial resolution pressure distribution of the vaginal canal in Pompoir practitioners: A biomechanical approach for assessing the pelvic floor.

    Science.gov (United States)

    Cacciari, Licia P; Pássaro, Anice C; Amorim, Amanda C; Sacco, Isabel C N

    2017-08-01

    Pompoir is a technique poorly studied in the literature that claims to improve pelvic floor strength and coordination. This study aims to investigate the pelvic floor muscles' coordination throughout the vaginal canal among Pompoir practitioners and non-practitioners by describing a high resolution map of pressure distribution. This cross-sectional, study included 40 healthy women in two groups: control and Pompoir. While these women performed both sustained and "waveform" pelvic floor muscle contractions, the spatiotemporal pressure distribution in their vaginal canals was evaluated by a non-deformable probe fully instrumented with a 10×10 matrix of capacitive transducers. Pompoir group was able to sustain the pressure levels achieved for a longer period (40% longer, moderate effect, P=0.04). During the "waveform" contraction task, Pompoir group achieved lower, earlier peak pressures (moderate effect, P=0.05) and decreased rates of contraction (small effect, P=0.04) and relaxation (large effect, P=0.01). During both tasks, Pompoir group had smaller relative contributions by the mid-region and the anteroposterior planes and greater contributions by the caudal and cranial regions and the latero-lateral planes. Results suggest that specific coordination training of the pelvic floor muscles alters the pressure distribution profile, promoting a more-symmetric distribution of pressure throughout the vaginal canal. Therefore, this study suggests that pelvic floor muscles can be trained to a degree beyond strengthening by focusing on coordination, which results in changes in symmetry of the spatiotemporal pressure distribution in the vaginal canal. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  20. Radiation effects of high and low doses

    International Nuclear Information System (INIS)

    El-Naggar, A.M.

    1998-01-01

    The extensive proliferation of the uses and applications of atomic and nuclear energy resulted in possible repercussions on human health. The prominent features of the health hazards that may be incurred after exposure to high and low radiation doses are discussed. The physical and biological factors involved in the sequential development of radiation health effects and the different cellular responses to radiation injury are considered. The main criteria and features of radiation effects of high and low doses are comprehensively outlined

  1. Extraperitoneal pelvic leiomyosarcoma

    International Nuclear Information System (INIS)

    Santamarina, Mario G.; Baltazar, Alberto D.; Arce, Patricia; Dettano, Veronica; Lopez, Jessica

    2003-01-01

    Extraperitoneal pelvic leiomyosarcoma is a very uncommon neoplasic process. It is a highly aggressive tumor with unfavorable prognosis. Clinical findings are nonspecific; diagnosis is generally made in an advanced stage of the disease. We present a case of a 34 years old female patient with pelvic leiomyosarcoma located at the recto vaginal septum who referred vulvar tumor and disability of the left lower limb. This case report describes the results obtained by ultrasound, Computed Tomography, Magnetic Resonance Imaging and pathology. (author)

  2. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  3. Pelvic X-ray examinations in follow-up of hip arthroplasty or femoral osteosynthesis – Dose reduction and quality criteria

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, Jost Karsten, E-mail: jost.kloth@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Rickert, Markus, E-mail: markus.rickert@ortho.med.uni-giessen.de [Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg, Klinikstrasse 33, D-35392 Giessen (Germany); Gotterbarm, Tobias, E-mail: tobias.gotterbarm@med.uni-heidelberg.de [Orthopedic and Trauma Surgery, University Hospital Heidelberg, Schlierbacher Landstraße 200a, D-69118 Heidelberg (Germany); Stiller, Wolfram, E-mail: wolfram.stiller@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Burkholder, Iris, E-mail: stabil@burkholder.de [Department of Nursing and Health, University of Applied Sciences of the Saarland, Goebenstrasse 40, D-66117 Saarbruecken (Germany); Kauczor, Hans-Ulrich, E-mail: hans-ulrich.kauczor@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Ewerbeck, Volker, E-mail: volker.ewerbeck@med.uni-heidelberg.de [Orthopedic and Trauma Surgery, University Hospital Heidelberg, Schlierbacher Landstraße 200a, D-69118 Heidelberg (Germany); Weber, Marc-André, E-mail: marcandre.weber@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany)

    2015-05-15

    Highlights: • Pelvic radiographs with speed class 400 and 800 in follow-up of hip arthroplasty were compared. • Radiographs with reduced dose (800) were not inferior to those with standard dose (400). • We recommend speed class 800 as new reference parameter in these examinations. - Abstract: Objective: Digital plain radiographs of the pelvis are frequently performed in follow-up examinations of patients who received total hip arthroplasty (THA) or osteosynthesis (OS). Thus, the purpose was to reduce the radiation dose and to determine objective quality control criteria to ensure accurate assessment. Materials and methods: Institutional review board approval was obtained. In this prospective randomized study, 289 patients underwent X-ray examination of the pelvis as follow up after receiving THA or OS with standard and reduced dose. The evaluation of the plain radiographs was conducted using the following criteria: bone–implant interface, implant–implant discrimination, implant–surface character and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score of 3 or more or more than 2 criteria with 2 points, the radiograph was scored as “not assessable“. The study was designed as non-inferiority-trial. Results: Seven (2.4%) examined X-rays were scored as not assessable. There was no statistical inferiority between the examinations with standard (0.365 mSv) or reduced dose (0.211 mSv). Reduced dose only led to limitations in the evaluation of ceramic components with low clinical impact in most scenarios. Conclusion: Plain radiography of the pelvis in patients with THA or OS can be performed with a dose reduction of about 42% without a loss of important information. The obtained quality control criteria were clinically applicable.

  4. Post operative high dose rate intravaginal irradiation in endometrial cancer: a safe and effective outpatient treatment

    International Nuclear Information System (INIS)

    Chen, Peter; Gibbons, Susan; Vicini, Frank; Weiner, Sheldon; Dmuchowski, Carl; Mele, Beth; Brabbins, Donald; Jennings, John; Gustafson, Gary; Martinez, Alvaro

    1995-01-01

    Purpose: We reviewed our experience with out patient high dose rate (HDR) intravaginal irradiation given post-operatively in endometrial cancer to assess local control, survival, and toxicity when used alone or in combination with external beam irradiation. Methods and Materials: From (12(88)) to (12(92)), 78 patients underwent TAH/BSO and received post-operative HDR intravaginal irradiation for endometrial cancer. Pathologic stage distribution was IB/IC: 56%, II: 22%, III: 22%. Adjuvant therapy was given in one of three schemes: HDR vaginal radiation alone (6 weekly fractions of 500 cGy prescribed 5 mm from the applicator surface treating the upper 4 cm of the vagina), pelvic irradiation with vaginal HDR (500 cGy x 4 weekly fractions) or whole abdomen/pelvic irradiation (WAPI) with vaginal HDR treatment (500 cGy x 3 weekly fractions). Prior to the first HDR vaginal treatment, a simulation with placement of vaginal apex metallic markers was performed to assure proper positioning of the intravaginal cylinders. Pelvic midline blocking was designed from the HDR intravaginal simulation films. The 55 patients who underwent combined external beam irradiation/brachytherapy received a median dose to the pelvis of 5040 cGy (range 25.2-51.6 Gy), and a median total vaginal dose of 5060 cGy (range 30.0-57.6 Gy). Results: Median follow-up is 37 months (range 6-73 months). Local control (vaginally) is 98.7%. The one vaginal failure was in the distal vagina, outside the treatment volume. All other failures (4) were distant with the vagina controlled [3 intra-abdominal and one bone/intra-abdominal]. For stages I and II, the disease free survival is 92.8%. For stage III the disease free survival is 86.5%. Median overall time to failure is 14.3 months (range 8.5-18.6 months). In terms of acute toxicity, no grade 3-4 acute toxicity of the vagina or bladder was seen. However, 9% acute GI toxicity was encountered. Chronic grade 1-2 toxicities included: vaginal 21.8% (foreshortening and

  5. An IGRT margin concept for pelvic lymph nodes in high-risk prostate cancer

    International Nuclear Information System (INIS)

    Groher, M.; Kopp, P.; Deutschmann, H.; Sedlmayer, F.; Wolf, Frank; Drerup, M.

    2017-01-01

    Gold-marker-based image-guided radiation therapy (IGRT) of the prostate allows to correct for inter- and intrafraction motion and therefore to safely reduce margins for the prostate planning target volume (PTV). However, pelvic PTVs, when coadministered in a single plan (registered to gold markers [GM]), require reassessment of the margin concept since prostate movement is independent from the pelvic bony anatomy to which the lymphatics are usually referenced to. We have therefore revisited prostate translational movement relative to the bony anatomy to obtain adequate margins for the pelvic PTVs compensating mismatch resulting from referencing pelvic target volumes to GMs in the prostate. Prostate movement was analyzed in a set of 28 patients (25 fractions each, totaling in 684 fractions) and the required margins calculated for the pelvic PTVs according to Van Herk's margin formula M = 2.5 Σ + 1.64 (σ ' -σ p ). The overall mean prostate movement relative to bony anatomy was 0.9 ± 3.1, 0.6 ± 3.4, and 0.0 ± 0.7 mm in anterior/posterior (A/P), inferior/superior (I/S) and left/right (L/R) direction, respectively. Calculated margins to compensate for the resulting mismatch to bony anatomy were 9/9/2 mm in A/P, I/S, and L/R direction and 10/11/6 mm if an additional residual error of 2 mm was assumed. GM-based IGRT for pelvic PTVs is feasible if margins are adapted accordingly. Margins could be reduced further if systematic errors which are introduced during the planning CT were eliminated. (orig.) [de

  6. Intracranial meningiomas after high-dose irradiation

    International Nuclear Information System (INIS)

    Soffer, D.; Gomori, J.M.; Siegal, T.; Shalit, M.N.

    1989-01-01

    Three patients who presented with intracranial meningiomas 12, 15, and 20 years, respectively, after therapeutic high-dose irradiation of a primary brain tumor are described. Analysis of these cases and similar documented cases suggests that meningiomas after high-dose irradiation constitute a recognizable entity. Patients with such tumors received radiation therapy at a young age (mean age, 9.4 years). After a latent period of 2 to 47 years (mean, 19.8 years) they developed meningiomas at the site of irradiation, at a much younger age than patients with ''spontaneous'' meningiomas. Similar to the situation with meningiomas after low-dose irradiation, a relatively high proportion of meningiomas induced by high-dose irradiation tend to be malignant and biologically aggressive. A very young age at the time of irradiation seems to predispose to the induction of malignant meningiomas, rather than benign tumors. These unusual features provide indirect evidence that high-dose radiation may play a role in the pathogenesis of meningiomas.41 references

  7. Results of radiation therapy for uterine cervical cancer using high dose rate remote after loading system

    International Nuclear Information System (INIS)

    Ogawa, Yoshihiro; Nemoto, Kenji

    2003-01-01

    In Japan, radiotherapy with high dose rate remote after loading system (HDR-RALS) for intracavitary brachytherapy is the standard treatment for more than 30 years. This report showed the usefulness of HDR-RALS for uterine cervical cancer. From 1980 through 1999, 442 patients with uterine cervical cancers (stage I: 66, stage II: 161, stage III: 165, stage IV: 50) were treated. Radiotherapy was performed both external teletherapy and HDR-RALS. Overall survival rate at 5 years was 60.2%. The 5-year actuarial incidence of all complications was 16.4%. The 5-year actuarial incidence of all complications in cases treated with the sum doses of whole pelvic irradiation (without central shield) and RALS up to 49 Gy, 50 to 59 Gy or larger doses were 7.5%, 11.0% and 25.2%, respectively. Radiation therapy using HDR-RALS was very effective. While the dose of whole pelvic irradiation was increased, the actuarial incidence of all complications was increased. (author)

  8. High-dose-rate versus low-dose-rate brachytherapy in the treatment of cervical cancer: analysis of tumor recurrence - the University of Wisconsin experience

    International Nuclear Information System (INIS)

    Petereit, Daniel G.; Sarkaria, Jann N.; Potter, David M.; Schink, Julian C.

    1999-01-01

    Purpose: To retrospectively compare the clinical outcome for cervical cancer patients treated with high-dose-rate (HDR) vs. low-dose-rate (LDR) brachytherapy. Methods and Materials: One hundred ninety-one LDR patients were treated from 1977 to 1988 and compared to 173 HDR patients treated from 1989 to 1996. Patients of similar stage and tumor volumes were treated with identical external beam fractionation schedules. Brachytherapy was given in either 1 or 2 LDR implants for the earlier patient cohort, and 5 HDR implants for the latter cohort. For both patient groups, Point A received a minimum total dose of 80 Gy. The linear-quadratic formula was used to calculate the LDR dose-equivalent contribution to Point A for the HDR treatments. The primary endpoints assessed were survival, pelvic control, relapse-free survival, and distant metastases. Endpoints were estimated using the Kaplan-Meier method. Comparisons between treatment groups were performed using the log-rank test and Cox proportional hazards models. Results: The median follow-up was 65 months (2 to 208 months) in the LDR group and 22 months (1 to 85 months) in the HDR group. For all stages combined there was no difference in survival, pelvic control, relapse-free survival, or distant metastases between LDR and HDR patients. For Stage IB and II HDR patients, the pelvic control rates were 85% and 80% with survival rates of 86% and 65% at 3 years, respectively. In the LDR group, Stage IB and II patients had 91% and 78% pelvic control rates, with 82% and 58% survival rates at 3 years, respectively. No difference was seen in survival or pelvic control for bulky Stage I and II patients combined (> 5 cm). Pelvic control at 3 years was 44% (HDR) versus 75% (LDR) for Stage IIIB patients (p = 0.002). This difference in pelvic control was associated with a lower survival rate in the Stage IIIB HDR versus LDR population (33% versus 58%, p = 0.004). The only major difference, with regard to patient characteristics

  9. Feasibility study of radiation dose reduction in adult female pelvic CT scan with low tube-voltage and adaptive statistical iterative econstruction

    International Nuclear Information System (INIS)

    Wang, Xin Lian; He, Wen; Chen, Jian Hong; Hu, Zhi Hai; Zhao, Li Qin

    2015-01-01

    To evaluate image quality of female pelvic computed tomography (CT) scans reconstructed with the adaptive statistical iterative reconstruction (ASIR) technique combined with low tube-voltage and to explore the feasibility of its clinical application. Ninety-four patients were divided into two groups. The study group used 100 kVp, and images were reconstructed with 30%, 50%, 70%, and 90% ASIR. The control group used 120 kVp, and images were reconstructed with 30% ASIR. The noise index was 15 for the study group and 11 for the control group. The CT values and noise levels of different tissues were measured. The contrast to noise ratio (CNR) was calculated. A subjective evaluation was carried out by two experienced radiologists. The CT dose index volume (CTDIvol) was recorded. A 44.7% reduction in CTDIvol was observed in the study group (8.18 ± 3.58 mGy) compared with that in the control group (14.78 ± 6.15 mGy). No significant differences were observed in the tissue noise levels and CNR values between the 70% ASIR group and the control group (p = 0.068-1.000). The subjective scores indicated that visibility of small structures, diagnostic confidence, and the overall image quality score in the 70% ASIR group was the best, and were similar to those in the control group (1.87 vs. 1.79, 1.26 vs. 1.28, and 4.53 vs. 4.57; p = 0.122-0.585). No significant difference in diagnostic accuracy was detected between the study group and the control group (42/47 vs. 43/47, p = 1.000). Low tube-voltage combined with automatic tube current modulation and 70% ASIR allowed the low CT radiation dose to be reduced by 44.7% without losing image quality on female pelvic scan

  10. Feasibility study of radiation dose reduction in adult female pelvic CT scan with low tube-voltage and adaptive statistical iterative econstruction

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xin Lian; He, Wen; Chen, Jian Hong; Hu, Zhi Hai; Zhao, Li Qin [Dept. of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing (China)

    2015-10-15

    To evaluate image quality of female pelvic computed tomography (CT) scans reconstructed with the adaptive statistical iterative reconstruction (ASIR) technique combined with low tube-voltage and to explore the feasibility of its clinical application. Ninety-four patients were divided into two groups. The study group used 100 kVp, and images were reconstructed with 30%, 50%, 70%, and 90% ASIR. The control group used 120 kVp, and images were reconstructed with 30% ASIR. The noise index was 15 for the study group and 11 for the control group. The CT values and noise levels of different tissues were measured. The contrast to noise ratio (CNR) was calculated. A subjective evaluation was carried out by two experienced radiologists. The CT dose index volume (CTDIvol) was recorded. A 44.7% reduction in CTDIvol was observed in the study group (8.18 ± 3.58 mGy) compared with that in the control group (14.78 ± 6.15 mGy). No significant differences were observed in the tissue noise levels and CNR values between the 70% ASIR group and the control group (p = 0.068-1.000). The subjective scores indicated that visibility of small structures, diagnostic confidence, and the overall image quality score in the 70% ASIR group was the best, and were similar to those in the control group (1.87 vs. 1.79, 1.26 vs. 1.28, and 4.53 vs. 4.57; p = 0.122-0.585). No significant difference in diagnostic accuracy was detected between the study group and the control group (42/47 vs. 43/47, p = 1.000). Low tube-voltage combined with automatic tube current modulation and 70% ASIR allowed the low CT radiation dose to be reduced by 44.7% without losing image quality on female pelvic scan.

  11. Feasibility Study of Radiation Dose Reduction in Adult Female Pelvic CT Scan with Low Tube-Voltage and Adaptive Statistical Iterative Reconstruction

    Science.gov (United States)

    Wang, Xinlian; Chen, Jianghong; Hu, Zhihai; Zhao, Liqin

    2015-01-01

    Objective To evaluate image quality of female pelvic computed tomography (CT) scans reconstructed with the adaptive statistical iterative reconstruction (ASIR) technique combined with low tube-voltage and to explore the feasibility of its clinical application. Materials and Methods Ninety-four patients were divided into two groups. The study group used 100 kVp, and images were reconstructed with 30%, 50%, 70%, and 90% ASIR. The control group used 120 kVp, and images were reconstructed with 30% ASIR. The noise index was 15 for the study group and 11 for the control group. The CT values and noise levels of different tissues were measured. The contrast to noise ratio (CNR) was calculated. A subjective evaluation was carried out by two experienced radiologists. The CT dose index volume (CTDIvol) was recorded. Results A 44.7% reduction in CTDIvol was observed in the study group (8.18 ± 3.58 mGy) compared with that in the control group (14.78 ± 6.15 mGy). No significant differences were observed in the tissue noise levels and CNR values between the 70% ASIR group and the control group (p = 0.068-1.000). The subjective scores indicated that visibility of small structures, diagnostic confidence, and the overall image quality score in the 70% ASIR group was the best, and were similar to those in the control group (1.87 vs. 1.79, 1.26 vs. 1.28, and 4.53 vs. 4.57; p = 0.122-0.585). No significant difference in diagnostic accuracy was detected between the study group and the control group (42/47 vs. 43/47, p = 1.000). Conclusion Low tube-voltage combined with automatic tube current modulation and 70% ASIR allowed the low CT radiation dose to be reduced by 44.7% without losing image quality on female pelvic scan. PMID:26357499

  12. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  13. SU-F-P-29: Impact of Oral Contrast Agent for Assisting in Outlining Small Intestine On Pelvic IMAT Dose in Patients with Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, R; Bai, W; Fan, X [The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei (China)

    2016-06-15

    Purpose: As the advanced intensity modulated arc therapy(IMAT) delivery systems becoming a main role of treatment ways, which places even greater demands on delivering accuracy. The impact of oral contrast agent (meglumine diatrizoate) for assisting in outlining the small intestine on pelvic IMAT dose in patients with cervical cancer was investigated. Methods: Ten cervical cancer patients for postoperative radiotherapy underwent CT scans, and the planning target volumes (PTV) and organs at risk (including the small intestine, rectum, bladder, colon and the left and right femoral head) were contoured. The IMAT plans were generated on Oncentra v4.1 planning system for each case, PTV was prescribed to 50.4 Gy in 28 fractions. Then another plan was generated by re-calculating the radiation dose after changing the electron density of the small bowel. The first plan (plan A) was the conventional IMAT plan (with oral contrast agent), and the second one (plan B) specified the electron density of the small bowel (without oral contrast agent). Paired t-test was used to compare the dose distribution between the two plans. Results: The PTV’s D2, D50, D95, V110, conformity index, and homogeneity index of plans A and B were 5610.5 vs. 5611.4 cGy (P=0.175), 5348.5 vs. 5348.0 cGy (P=0.869), 5039 vs. 5042.3 (P=0.518), 6.0% vs. 6.1 %( P=0.886), 0.1269 vs. 0.1271 (P=0.34) and 0.8421 vs. 0.8416 (P=0.598), respectively. The volumes of the small bowel receiving at least 30 Gy (V30) and the minimum dose of 2% volume accepted (D2) for plans A and B were 31.6% vs. 31.9% (P=0.371) and 5067.8 vs. 5085.4 cGy (P=0.377), while rectum V50 of the two plans was 12.4% vs. 12.1% (P=0.489). Conclusion: The oral contrast agent (meglumine diatrizoate) filling the small intestine does not lead to a significant increase in the pelvic IMAT dose in patients with cervical cancer.

  14. Pelvic Pain

    Science.gov (United States)

    ... OLPP) Office of Science Policy, Reporting, and Program Analysis (OSPRA) Division of Extramural Research (DER) Extramural Scientific ... treat my pain? Can pelvic pain affect my emotional well-being? How can I cope with long- ...

  15. Pelvic Exam

    Science.gov (United States)

    ... each step so that nothing comes as a surprise to you. After the pelvic exam After the ... Clinic does not endorse any of the third party products and services advertised. Advertising and sponsorship policy ...

  16. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  17. Early weight-bearing after periacetabular osteotomy leads to a high incidence of postoperative pelvic fractures.

    Science.gov (United States)

    Ito, Hiroshi; Tanino, Hiromasa; Sato, Tatsuya; Nishida, Yasuhiro; Matsuno, Takeo

    2014-07-11

    It has not been shown whether accelerated rehabilitation following periacetabular osteotomy (PAO) is effective for early recovery. The purpose of this retrospective study was to compare complication rates in patients with standard and accelerated rehabilitation protocols who underwent PAO. Between January 2002 and August 2011, patients with a lateral center-edge (CE) angle of rehabilitation protocol. In 65 patients (76 hips) with the accelerated rehabilitation protocol, postoperative strengthening of the hip, thigh and core musculature was begun on the day of surgery as tolerated. The exercise program included active hip range of motion, and gentle isometric hamstring and quadriceps muscle sets; these exercises were performed for 30 minutes in the morning and 30 minutes in the afternoon with a physical therapist every weekday for 6 weeks. Full weight-bearing with two axillary crutches started on the day of surgery as tolerated. Complications were evaluated for 2 years. The clinical results at the time of follow-up were similar in the two groups. The average periods between the osteotomy and full-weight-bearing walking without support were 4.2 months and 6.9 months in patients with the accelerated and standard rehabilitation protocols (P rehabilitation protocol could achieve earlier recovery of patients. However, postoperative fractures of the ischial ramus and posterior column of the pelvis were more frequently found in patients with the accelerated rehabilitation protocol (8/76) than in those with the standard rehabilitation protocol (1/80) (P = 0.013). The accelerated rehabilitation protocol seems to have advantages for early muscle recovery in patients undergoing PAO; however, postoperative pelvic fracture rates were unacceptably high in patients with this protocol.

  18. Nonlinear model of high-dose implantation

    International Nuclear Information System (INIS)

    Danilyuk, A.

    2001-01-01

    The models of high-dose implantation, using the distribution functions, are relatively simple. However, they must take into account the variation of the function of distribution of the implanted ions with increasing dose [1-4]. This variation takes place owing to the fact that the increase of the concentration of the implanted ions results in a change of the properties of the target. High-dose implantation is accompanied by sputtering, volume growth, diffusion, generation of defects, formation of new phases, etc. The variation of the distribution function is determined by many factors and is not known in advance. The variation within the framework of these models [1-4] is taken into account in advance by the introduction of intuitive assumptions on the basis of implicit considerations. Therefore, these attempts should be regarded as incorrect. The model prepared here makes it possible to take into account the sputtering of the target, volume growth and additional declaration on the implanted ions. Without any assumptions in relation to the variation of the distribution function with increasing dose. In our model it is assumed that the type of distribution function for small doses in a pure target substance is the same as in substances with implanted ions. A second assumption relates to the type of the distribution function valid for small doses in the given substances. These functions are determined as a result of a large number of theoretical and experimental investigations and are well-known at the present time. They include the symmetric and nonsymmetric Gauss distribution, the Pearson distribution, and others. We examine implantation with small doses of up to 10 14 - 10 15 cm -2 when the accurately known distribution is valid

  19. High dose gamma-ray standard

    International Nuclear Information System (INIS)

    Macrin, R.; Moraru, R.

    1999-01-01

    The high gamma-ray doses produced in a gamma irradiator are used, mainly, for radiation processing, i.e. sterilization of medical products, processing of food, modifications of polymers, irradiation of electronic devices, a.s.o. The used absorbed doses depend on the application and cover the range 10 Gy to 100 MGy. The regulations in our country require that the response of the dosimetry systems, used for the irradiation of food and medical products, be calibrated and traceable to the national standards. In order to be sure that the products receive the desired absorbed dose, appropriate dosimetric measurements must be performed, including the calibration of the dosemeters and their traceability to the national standards. The high dose gamma-ray measurements are predominantly based on the use of reference radiochemical dosemeters. Among them the ferrous sulfate can be used as reference dosemeter for low doses (up to 400 Gy) but due to its characteristics it deserves to be considered a standard dosemeter and to be used for transferring the conventional absorbed dose to other chemical dosemeters used for absorbed doses up to 100 MGy. The study of the ferrous sulfate dosemeter consisted in preparing many batches of solution by different operators in quality assurance conditions and in determining for all batches the linearity, the relative intrinsic error, the repeatability and the reproducibility. The principal results are the following: the linear regression coefficient: 0.999, the relative intrinsic error: max.6 %, the repeatability (for P* = 95 %): max.3 %, the reproducibility (P* = 95%): max.5 %. (authors)

  20. Comparison of high-dose-rate and low-dose-rate brachytherapy in the treatment of endometrial carcinoma

    International Nuclear Information System (INIS)

    Fayed, Alaa; Mutch, David G.; Rader, Janet S.; Gibb, Randall K.; Powell, Matthew A.; Wright, Jason D.; El Naqa, Issam; Zoberi, Imran; Grigsby, Perry W.

    2007-01-01

    Purpose: To compare the outcomes for endometrial carcinoma patients treated with either high-dose-rate (HDR) or low-dose-rate (LDR) brachytherapy. Methods and Materials: This study included 1,179 patients divided into LDR (1,004) and HDR groups (175). Patients with International Federation of Gynecology and Obstetrics (FIGO) surgical Stages I-III were included. All patients were treated with postoperative irradiation. In the LDR group, the postoperative dose applied to the vaginal cuff was 60-70 Gy surface doses to the vaginal mucosa. The HDR brachytherapy prescription was 6 fractions of 2 Gy each to a depth of 0.5 cm from the surface of the vaginal mucosa. Overall survival, disease-free survival, local control, and complications were endpoints. Results: For all stages combined, the overall survival, disease-free survival, and local control at 5 years in the LDR group were 70%, 69%, and 81%, respectively. For all stages combined, the overall survival, disease-free survival, and local control at 5 years in the HDR group were 68%, 62%, and 78%, respectively. There were no significant differences in early or late Grade III and IV complications in the HDR or LDR groups. Conclusion: Survival outcomes, pelvic tumor control, and Grade III and IV complications were not significantly different in the LDR brachytherapy group compared with the HDR group

  1. Outcome According to Elective Pelvic Radiation Therapy in Patients With High-Risk Localized Prostate Cancer: A Secondary Analysis of the GETUG 12 Phase 3 Randomized Trial.

    Science.gov (United States)

    Blanchard, Pierre; Faivre, Laura; Lesaunier, François; Salem, Naji; Mesgouez-Nebout, Nathalie; Deniau-Alexandre, Elisabeth; Rolland, Frédéric; Ferrero, Jean-Marc; Houédé, Nadine; Mourey, Loïc; Théodore, Christine; Krakowski, Ivan; Berdah, Jean-François; Baciuchka, Marjorie; Laguerre, Brigitte; Davin, Jean-Louis; Habibian, Muriel; Culine, Stéphane; Laplanche, Agnès; Fizazi, Karim

    2016-01-01

    The role of pelvic elective nodal irradiation (ENI) in the management of prostate cancer is controversial. This study analyzed the role of pelvic radiation therapy (RT) on the outcome in high-risk localized prostate cancer patients included in the Groupe d'Etude des Tumeurs Uro-Genitales (GETUG) 12 trial. Patients with a nonpretreated high-risk localized prostate cancer and a staging lymphadenectomy were randomly assigned to receive either goserelin every 3 months for 3 years and 4 cycles of docetaxel plus estramustine or goserelin alone. Local therapy was administered 3 months after the start of systemic treatment. Performance of pelvic ENI was left to the treating physician. Only patients treated with primary RT were included in this analysis. The primary endpoint was biochemical progression-free survival (bPFS). A total of 413 patients treated from 2002 to 2006 were included, of whom 358 were treated using primary RT. A total of 208 patients received pelvic RT and 150 prostate-only RT. Prostate-specific antigen (PSA) concentration, Gleason score, or T stage did not differ according to performance of pelvic RT; pN+ patients more frequently received pelvic RT than pN0 patients (PENI in multivariate analysis (HR: 1.10 [95% CI: 0.78-1.55], P=.60), even when analysis was restricted to pN0 patients (HR: 0.88 [95% CI: 0.59-1.31], P=.53). Pelvic ENI was not associated with increased acute or late patient reported toxicity. This unplanned analysis of a randomized trial failed to demonstrate a benefit of pelvic ENI on bPFS in high-risk localized prostate cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. NIST high-dose calibration services

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1989-01-01

    There is a need for the standardization of high-dose measurements used in the radiation-processing industry in order to provide assured traceability to national standards. NIST provides dosimetry calibration services to this industry. One of these services involves administration of known absorbed doses of gamma rays to customer-supplied dosimeters. The dosimeters are packaged to provide electron equilibrium conditions and are irradiated in a standard 60 Co calibration facility; this provides a calibration of that batch of dosimeters. Another service consists of supplying to a customer calibrated transfer dosimeters for irradiation with the customer's radiation source. The irradiated transfer dosimeters are then returned to NIST for analysis; the results are reported to the customer, providing a calibration of the dose rate of the customer's source. (orig.)

  3. Intracavitary irradiation of prostatic carcinoma by a high dose-rate afterloading technique

    Energy Technology Data Exchange (ETDEWEB)

    Odelberg-Johnson, O.; Underskog, I.; Johansson, J.E.; Bernshaw, D.; Sorbe, B.; Persson, J.E. (Oerebro Medical Center Hospital (Sweden). Dept. of Oncology Oerebro Medical Center Hospital (Sweden). Dept. of Urology Oerebro Medical Center Hospital (Sweden). Dept. of Gynecologic Oncology Oerebro Medical Center Hospital (Sweden). Dept. of Radiation Physics)

    1991-01-01

    A high dose-rate ({sup 60}Co) afterloading technique was evaluated in a series of 73 patients with prostatic carcinoma stages I-IV. The intraurethral irradiation was combined with external pelvic radiotherapy. A minimum total dose of 78 Gy was delivered to the target volume. In a subgroup of patients extramustine (Estracyt) was given as adjuvant chemohormonal therapy during irradiation. The median follow-up for the whole group was 63 months. The crude 5-year survival rate was 60% and the corrected survival rate 90%. Survival was related to the tumor grade. Local pelvic recurrences were recorded in 17.8%. 'Viable cells' in posttherapy aspiration biopsy were not associated with tumor recurrences or survival. Four patients (5%) had grade 3 late radiation reactions with urethral structure or bladder fibrosis. Urinary tract infections and prior transurethral resections were not associated with a higher frequency of reactions. Concurrent estramustine therapy seemed to increase the frequency of both acute and chronic radiation reactions. Local control, recurrence, and survival were not affected by chemohormonal therapy. The use of tomography, magnetic resonance, and ultrasound as aids to computerized dosimetry may improve local dose distribution and reduce the irradiated volume. (orig.).

  4. Pelvic Actinomycosis

    Directory of Open Access Journals (Sweden)

    Alejandra García-García

    2017-01-01

    Full Text Available Introduction. Actinomycosis is a chronic bacterial infection caused by Actinomyces, Gram-positive anaerobic bacteria. Its symptomatology imitates some malignant pelvic tumours, tuberculosis, or nocardiosis, causing abscesses and fistulas. Actinomycoses are opportunistic infections and require normal mucous barriers to be altered. No epidemiological studies have been conducted to determine prevalence or incidence of such infections. Objective. To analyse the clinical cases of pelvic actinomycosis reported worldwide, to update the information about the disease. Methods. A systematic review of worldwide pelvic actinomycosis cases between 1980 and 2014 was performed, utilising the PubMed, Scopus, and Google Scholar databases. The following information was analysed: year, country, type of study, number of cases, use of intrauterine device (IUD, final and initial diagnosis, and method of diagnosis. Results. 63 articles met the search criteria, of which 55 reported clinical cases and 8 reported cross-sectional studies. Conclusions. Pelvic actinomycosis is confusing to diagnose and should be considered in the differential diagnosis of pelvic chronic inflammatory lesions. It is commonly diagnosed through a histological report, obtained after a surgery subsequent to an erroneous initial diagnosis. A bacterial culture in anaerobic medium could be useful for the diagnosis but requires a controlled technique and should be performed using specialised equipment.

  5. Treatment of carcinoma of uterine cervix with high-dose-rate intracavitary irradiation using Ralstron

    International Nuclear Information System (INIS)

    Suh, C.O.; Kim, G.E.; Loh, J.J.K.

    1988-01-01

    From May 1979 through December 1981, a total of 530 patients with carcinoma of the uterine cervix were treated with radiation therapy with curative intent. Of the 530 patients, 365 were treated with a high-dose-rate remote-controlled afterloading system (RALS) using a cobalt source, and 165 patients received a low dose rate using a radium source. External pelvic irradiation with a total of 40-50 Gy to the whole pelvis followed by intracavitary radiation (ICR) with a total dose of 30-39 Gy in ten to 13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rate with high-dose-rate ICR by stage was as follows: stage I:82.7% (N = 19) stage II:69.6% (N = 184), and stage III:52.2% (N = 156). The above results were comparable with those with conventional low-dose-rate ICR treatment, and late complications were far less. The application of high-dose-rate ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually none as compared with that of low-dose-rate ICR. Within a given period of time, more patients can be treated with high-dose-rate ICR because of the short treatment time. The authors therefore conclude that high-dose-rate ICR is suitable for a cancer center where a large number of patients are to be treated

  6. High-dose erythropoietin for tissue protection

    DEFF Research Database (Denmark)

    Lund, Anton; Lundby, Carsten; Olsen, Niels Vidiendal

    2014-01-01

    BACKGROUND: The discovery of potential anti-apoptotic and cytoprotective effects of recombinant human erythropoietin (rHuEPO) has led to clinical trials investigating the use of high-dose, short-term rHuEPO therapy for tissue protection in conditions such as stroke and myocardial infarction....... Experimental studies have been favourable, but the clinical efficacy has yet to be validated. MATERIALS AND METHODS: We have reviewed clinical studies regarding the use of high-dose, short-term rHuEPO therapy for tissue protection in humans with the purpose to detail the safety and efficacy of r...... no effect of rHuEPO therapy on measures of tissue protection. Five trials including 1025 patients reported safety concerns in the form of increased mortality or adverse event rates. No studies reported reduced mortality. CONCLUSIONS: Evidence is sparse to support a tissue-protective benefit of r...

  7. Laparoscopic pelvic sling placement facilitates optimum therapeutic radiotherapy delivery in the management of pelvic malignancy.

    LENUS (Irish Health Repository)

    Joyce, M

    2012-02-01

    BACKGROUND: Radiotherapy has a significant role in the management of pelvic malignancies. However, the small intestine represents the main dose limiting organ. Invasive and non-invasive mechanical methods have been described to displace bowel out of the radiation field. We herein report a case series of laparoscopic placement of an absorbable pelvic sling in patients requiring pelvic radiotherapy. METHODS: Six patients were referred to our minimally invasive unit. Four patients required radical radiotherapy for localised prostate cancer, one was scheduled for salvage localised radiotherapy for post-prostatectomy PSA progression and one patient required adjuvant radiotherapy post-cystoprostatectomy for bladder carcinoma. All patients had excessive small intestine within the radiation fields despite the use of non-invasive displacement methods. RESULTS: All patients underwent laparoscopic mesh placement, allowing for an elevation of small bowel from the pelvis. The presence of an ileal conduit or previous surgery did not prevent mesh placement. Post-operative planning radiotherapy CT scans confirmed displacement of the small intestine allowing all patients to receive safely the planned radiotherapy in terms of both volume and radiation schedule. CONCLUSION: Laparoscopic mesh placement represents a safe and efficient procedure in patients requiring high-dose pelvic radiation, presenting with unacceptable small intestine volume in the radiation field. This procedure is also feasible in those that have undergone previous major abdominal surgery.

  8. Interim report of image-guided conformal high-dose-rate brachytherapy for patients with unfavorable prostate cancer: the William Beaumont Phase II dose-escalating trial

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Kestin, Larry L.; Stromberg, Jannifer S.; Gonzalez, Jose A.; Wallace, Michelle; Gustafson, Gary S.; Edmundson, Gregory K.; Spencer, William; Vicini, Frank A.

    2000-01-01

    Purpose: We analyzed our institution's experience treating patients with unfavorable prostate cancer in a prospective Phase II dose-escalating trial of external beam radiation therapy (EBRT) integrated with conformal high-dose-rate (HDR) brachytherapy boosts. This interim report discusses treatment outcome and prognostic factors using this treatment approach. Methods and Materials: From November 1991 through February 1998, 142 patients with unfavorable prostate cancer were prospectively treated in a dose-escalating trial with pelvic EBRT in combination with outpatient HDR brachytherapy at William Beaumont Hospital. Patients with any of the following characteristics were eligible: pretreatment prostate-specific antigen (PSA) ≥ 10.0 ng/ml, Gleason score ≥ 7, or clinical stage T2b or higher. All patients received pelvic EBRT to a median total dose of 46.0 Gy. Pelvic EBRT was integrated with ultrasound-guided transperineal conformal interstitial iridium-192 HDR implants. From 1991 to 1995, 58 patients underwent three conformal interstitial HDR implants during the first, second, and third weeks of pelvic EBRT. After October 1995, 84 patients received two interstitial implants during the first and third weeks of pelvic EBRT. The dose delivered via interstitial brachytherapy was escalated from 5.50 Gy to 6.50 Gy for each implant in those patients receiving three implants, and subsequently, from 8.25 Gy to 9.50 Gy per fraction in those patients receiving two implants. To improve implant quality and reduce operator dependency, an on-line, image-guided interactive dose optimization program was utilized during each HDR implant. No patient received hormonal therapy unless treatment failure was documented. The median follow-up was 2.1 years (range: 0.2-7.2 years). Biochemical failure was defined according to the American Society for Therapeutic Radiology and Oncology Consensus Panel definition. Results: The pretreatment PSA level was ≥ 10.0 ng/ml in 51% of patients. The

  9. High dose rate brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Koizumi, Masahiko; Ogawa, Kazuhiko; Furukawa, Souhei

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. (author)

  10. High dose rate brachytherapy for oral cancer.

    Science.gov (United States)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  11. Update on pediatric resuscitation drugs: high dose, low dose, or no dose at all.

    Science.gov (United States)

    Sorrentino, Annalise

    2005-04-01

    Pediatric resuscitation has been a topic of discussion for years. It is difficult to keep abreast of changing recommendations, especially for busy pediatricians who do not regularly use these skills. This review will focus on the most recent guidelines for resuscitation drugs. Three specific questions will be discussed: standard dose versus high-dose epinephrine, amiodarone use, and the future of vasopressin in pediatric resuscitation. The issue of using high-dose epinephrine for cardiopulmonary resuscitation refractory to standard dose epinephrine has been a topic of debate for many years. Recently, a prospective, double-blinded study was performed to help settle the debate. These results will be reviewed and compared with previous studies. Amiodarone is a medication that was added to the pediatric resuscitation algorithms with the most recent recommendations from the American Heart Association in 2000. Its use and safety will also be discussed. Another topic that is resurfacing in resuscitation is the use of vasopressin. Its mechanism and comparisons to other agents will be highlighted, although its use in the pediatric patient has not been thoroughly studied. Pediatric resuscitation is a constantly evolving subject that is on the mind of anyone taking care of sick children. Clinicians are continually searching for the most effective methods to resuscitate children in terms of short- and long-term outcomes. It is important to be familiar with not only the agents being used but also the optimal way to use them.

  12. An IGRT margin concept for pelvic lymph nodes in high-risk prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Groher, M.; Kopp, P.; Deutschmann, H.; Sedlmayer, F.; Wolf, Frank [Paracelsus Medical University of Salzburg, Department of Radiation Oncology, St. Johanns-Spital, Salzburg (Austria); Drerup, M. [Paracelsus Medical University of Salzburg, Department of Urology, St. Johanns-Spital, Salzburg (Austria)

    2017-09-15

    Gold-marker-based image-guided radiation therapy (IGRT) of the prostate allows to correct for inter- and intrafraction motion and therefore to safely reduce margins for the prostate planning target volume (PTV). However, pelvic PTVs, when coadministered in a single plan (registered to gold markers [GM]), require reassessment of the margin concept since prostate movement is independent from the pelvic bony anatomy to which the lymphatics are usually referenced to. We have therefore revisited prostate translational movement relative to the bony anatomy to obtain adequate margins for the pelvic PTVs compensating mismatch resulting from referencing pelvic target volumes to GMs in the prostate. Prostate movement was analyzed in a set of 28 patients (25 fractions each, totaling in 684 fractions) and the required margins calculated for the pelvic PTVs according to Van Herk's margin formula M = 2.5 Σ + 1.64 (σ{sup '}-σ{sub p}). The overall mean prostate movement relative to bony anatomy was 0.9 ± 3.1, 0.6 ± 3.4, and 0.0 ± 0.7 mm in anterior/posterior (A/P), inferior/superior (I/S) and left/right (L/R) direction, respectively. Calculated margins to compensate for the resulting mismatch to bony anatomy were 9/9/2 mm in A/P, I/S, and L/R direction and 10/11/6 mm if an additional residual error of 2 mm was assumed. GM-based IGRT for pelvic PTVs is feasible if margins are adapted accordingly. Margins could be reduced further if systematic errors which are introduced during the planning CT were eliminated. (orig.) [German] Eine Goldmarker-(GM-)basierte, bildgefuehrte Radiotherapie der Prostata ermoeglicht inter- und intrafraktionelle Bewegungen auszugleichen und somit Sicherheitsraender der Planungszielvolumina (PTV) zu minimieren. Dies gilt jedoch nicht fuer Zielvolumina des pelvinen Lymphabflusses, wenn diese im Rahmen eines simultan integrierten Boost-Konzepts im selben Plan verabreicht werden. Da Bewegungen der Prostata und des Lymphabflusses unabhaengig

  13. Re-irradiation: Outcome, cumulative dose and toxicity in patients retreated with stereotactic radiotherapy in the abdominal or pelvic region

    NARCIS (Netherlands)

    H. Abusaris (Huda); M.S. Hoogeman (Mischa); J.J.M.E. Nuyttens (Joost)

    2012-01-01

    textabstractThe purpose of the present study was to explore the outcome, cumulative dose in tumor and organs at risk and toxicity after extra-cranial stereotactic re-irradiation. Twenty-seven patients were evaluated who had been re-irradiated with stereotactic body radiotherapy (SBRT) after

  14. Post Pelvic Radiotherapy Bony Changes

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Seung Jae [Samsung Medical Center, Seoul (Korea, Republic of)

    2009-03-15

    There has been recent interest in radiation-induced bone injury in clinical conditions, especially for pelvic insufficiency fracture (PIF). A PIF is caused by the effect of normal or physiological stress on bone with demineralization and decreased elastic resistance. Pelvic radiotherapy (RT) can also contribute to the development of a PIF. A PIF has been regarded as a rare complication with the use of megavoltage equipment. However, recent studies have reported the incidence of PIFs as 8.2{approx}20% after pelvic RT in gynecological patients, an incidence that was higher than previously believed. The importance of understanding a PIF lies in the potential for misdiagnosis as a bony metastasis. If patients complain of pelvic pain after whole-pelvis radiation therapy, the presence of a PIF must be considered in the differential diagnosis. The use of multibeam arrangements and conformal RT to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture. In addition to a PIF, osteonecrosis and avascular necrosis of the femoral head can develop after radiation therapy. Osteoradionecrosis of the pelvic bone is a clinical diagnostic challenge that must be differentiated from an osseous metastasis. A post-radiation bone sarcoma can result as a long-term sequela of pelvic irradiation for uterine cervical cancer.

  15. SU-G-IeP2-03: Comparison of Dose Calculation On MAR (metal Artifact Reduction) and Non-MAR Datasets for Pelvic Patients with Hip Prosthesis and Head and Neck Patients with Dental Filling

    International Nuclear Information System (INIS)

    Huang, V; Kohli, K

    2016-01-01

    Purpose: Metal artifact reduction (MAR) software in computed tomography (CT) was previously evaluated with phantoms demonstrating the algorithm is capable of reducing metal artifacts without affecting the overall image quality. The goal of this study is to determine the dosimetric impact when calculating with CT datasets reconstructed with and without MAR software. Methods: Twelve head and neck cancer patients with dental fillings and four pelvic cancer patients with hip prosthesis were scanned with a GE Optima RT 580 CT scanner. Images were reconstructed with and without the MAR software. 6MV IMRT and VMAT plans were calculated with AAA on the MAR dataset until all constraints met our clinic’s guidelines. Contours from the MAR dataset were copied to the non-MAR dataset. Next, dose calculation on the non-MAR dataset was performed using the same field arrangements and fluence as the MAR plan. Conformality index, D99% and V100% to PTV were compared between MAR and non-MAR plans. Results: Differences between MAR and non-MAR plans were evaluated. For head and neck plans, the largest variations in conformality index, D99% and V100% were −3.8%, −0.9% and −2.1% respectively whereas for pelvic plans, the biggest discrepancies were −32.7%, −0.4% and -33.5% respectively. The dosimetric impact from hip prosthesis is greater because it produces more artifacts compared to dental fillings. Coverage to PTV can increase or decrease depending on the artifacts since dark streaks reduce the HU whereas bright streaks increase the HU. In the majority of the cases, PTV dose in the non-MAR plans is higher than MAR plans. Conclusion: With the presence of metals, MAR algorithm can allow more accurate delineation of targets and OARs. Dose difference between MAR and non-MAR plans depends on the proximity of the organ to the high density material, the streaking artifacts and the beam arrangements of the plan.

  16. SU-G-IeP2-03: Comparison of Dose Calculation On MAR (metal Artifact Reduction) and Non-MAR Datasets for Pelvic Patients with Hip Prosthesis and Head and Neck Patients with Dental Filling

    Energy Technology Data Exchange (ETDEWEB)

    Huang, V; Kohli, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2016-06-15

    Purpose: Metal artifact reduction (MAR) software in computed tomography (CT) was previously evaluated with phantoms demonstrating the algorithm is capable of reducing metal artifacts without affecting the overall image quality. The goal of this study is to determine the dosimetric impact when calculating with CT datasets reconstructed with and without MAR software. Methods: Twelve head and neck cancer patients with dental fillings and four pelvic cancer patients with hip prosthesis were scanned with a GE Optima RT 580 CT scanner. Images were reconstructed with and without the MAR software. 6MV IMRT and VMAT plans were calculated with AAA on the MAR dataset until all constraints met our clinic’s guidelines. Contours from the MAR dataset were copied to the non-MAR dataset. Next, dose calculation on the non-MAR dataset was performed using the same field arrangements and fluence as the MAR plan. Conformality index, D99% and V100% to PTV were compared between MAR and non-MAR plans. Results: Differences between MAR and non-MAR plans were evaluated. For head and neck plans, the largest variations in conformality index, D99% and V100% were −3.8%, −0.9% and −2.1% respectively whereas for pelvic plans, the biggest discrepancies were −32.7%, −0.4% and -33.5% respectively. The dosimetric impact from hip prosthesis is greater because it produces more artifacts compared to dental fillings. Coverage to PTV can increase or decrease depending on the artifacts since dark streaks reduce the HU whereas bright streaks increase the HU. In the majority of the cases, PTV dose in the non-MAR plans is higher than MAR plans. Conclusion: With the presence of metals, MAR algorithm can allow more accurate delineation of targets and OARs. Dose difference between MAR and non-MAR plans depends on the proximity of the organ to the high density material, the streaking artifacts and the beam arrangements of the plan.

  17. Postoperative low-pelvic irradiation for stage I-IIA cervical cancer patients with risk factors other than pelvic lymph node metastasis

    International Nuclear Information System (INIS)

    Hong, J.-H.; Tsai, C.-S.; Lai, C.-H.; Chang, T.-C.; Wang, C.-C.; Lee, Steve P.; Tseng, C.-J.; Hsueh, Swei

    2002-01-01

    Purpose: To retrospectively investigate whether postoperative low-pelvic radiotherapy (RT) is an appropriate treatment for node-negative, high-risk Stage I-IIA cervical cancer patients. Methods and Materials: A total of 228 Stage I-IIA cervical cancer patients treated by radical surgery and postoperative RT were included in this study. All patients had histopathologically negative pelvic node metastasis, but at least one of the following risk factors: parametrial involvement, positive or close resection margins, invasion depth two-thirds or greater cervical stromal thickness. Seventy-nine patients (35%) received 30-50 Gy (median 44) to whole pelvis and a boost dose to the low pelvis (whole-pelvic RT group); the other 149 patients (65%) received low-pelvic RT only (low-pelvic RT group). For both groups, the total external RT dose to the low pelvis ranged from 40 to 60 Gy (median 50). The potential factors associated with survival, small bowel (gastrointestinal) complications, and leg lymphedema were analyzed, and patients who had a relapse in the upper pelvis were identified. Results: The 5-year overall and disease-specific survival rate was 84% and 86%, respectively. After multivariate analysis, only bulky tumor (≥4 cm) and non-squamous cell carcinoma were significantly associated with survival. Parametrial involvement, lymph-vascular invasion, ≤50.4 Gy to the low pelvis, positive or close margins, and low-pelvic RT alone did not significantly affect survival. Grade I-V small bowel complications occurred in 33 patients (15%). Whole pelvic RT and >50.4 Gy to the low pelvis, but not old age and treatment technique (AP-PA vs. box), were significantly associated with gastrointestinal complications. Three patients (2%) in the low-pelvic RT group and 6 patients (8%) in the whole-pelvic RT group were found to have Grade III or higher small bowel complications (p=0.023). Thirty-one percent of patients developed lymphedema of the leg. A dose to the low pelvis >50.4 Gy

  18. High dose rate endobronchial brachytherapy - treatment technique

    International Nuclear Information System (INIS)

    Carvalho, Heloisa de Andrade; Aisen, Salim; Haddad, Cecilia Maria Kalil; Nadalin, Wladimir; Pedreira Junior, Wilson Leite; Chavantes, Maria Cristina

    1998-01-01

    High dose rate endobronchial brachytherapy is efficient in symptom relief due to obstructive endobronchial malignancies. However, it's role in survival improvement for patients with lung cancer is not yet established. The use of this treatment in increasing, specially in the developing countries. The purpose of this paper is to present the treatment technique used in the Radiotherapy Department of the Hospital da Clinicas, University of Sao Paulo, based on an experience of 60 cases treated with 180 procedures. Some practical suggestions and rules adopted in the Department are described. The severe complications rate is 6.7%, demonstrating an adequate patient selection associated with the technique utilized. (author)

  19. Neuroprotective potential of high-dose biotin.

    Science.gov (United States)

    McCarty, Mark F; DiNicolantonio, James J

    2017-11-01

    A recent controlled trial has established that high-dose biotin supplementation - 100 mg, three times daily - has a stabilizing effect on progression of multiple sclerosis (MS). Although this effect has been attributed to an optimization of biotin's essential cofactor role in the brain, a case can be made that direct stimulation of soluble guanylate cyclase (sGC) by pharmacological concentrations of biotin plays a key role in this regard. The utility of high-dose biotin in MS might reflect an anti-inflammatory effect of cGMP on the cerebral microvasculature, as well on oligodendrocyte differentiation and on Schwann cell production of neurotrophic factors thought to have potential for managing MS. But biotin's ability to boost cGMP synthesis in the brain may have broader neuroprotective potential. In many types of neurons and neural cells, cGMP exerts neurotrophic-mimetic effects - entailing activation of the PI3K-Akt and Ras-ERK pathways - that promote neuron survival and plasticity. Hippocampal long term potentiation requires nitric oxide synthesis, which in turn promotes an activating phosphorylation of CREB via a pathway involving cGMP and protein kinase G (PKG). In Alzheimer's disease (AD), amyloid beta suppresses this mechanism by inhibiting sGC activity; agents which exert a countervailing effect by boosting cGMP levels tend to restore effective long-term potentiation in rodent models of AD. Moreover, NO/cGMP suppresses amyloid beta production within the brain by inhibiting expression of amyloid precursor protein and BACE1. In conjunction with cGMP's ability to oppose neuron apoptosis, these effects suggest that high-dose biotin might have potential for the prevention and management of AD. cGMP also promotes neurogenesis, and may lessen stroke risk by impeding atherogenesis and hypertrophic remodeling in the cerebral vasculature. The neuroprotective potential of high-dose biotin likely could be boosted by concurrent administration of brain

  20. In vivo tissue heterogeneity influence on dose distributhon in high energy radiotheraphy with x ray

    International Nuclear Information System (INIS)

    Aldred, M.A.

    1987-01-01

    In vivo effects of tissue heterogeneity of pelvic region on dose distribution are studied. Eight patients under radiotherapy with linear accelerator are analysed. Thermoluminescent dosimeters placed under the skin are used for dose measurements of radiation beams. A comparative evaluation between this study and homogeneneous phantoms is presented. (M.A.C.) [pt

  1. Outcome According to Elective Pelvic Radiation Therapy in Patients With High-Risk Localized Prostate Cancer: A Secondary Analysis of the GETUG 12 Phase 3 Randomized Trial

    Energy Technology Data Exchange (ETDEWEB)

    Blanchard, Pierre, E-mail: pierre.blanchard@gustaveroussy.fr [Radiation Oncology, Gustave Roussy Cancer Center, Villejuif (France); University of Paris-Sud, Cancer Campus, Villejuif (France); Faivre, Laura [Biostatistics, Gustave Roussy Cancer Center, Villejuif (France); Lesaunier, François [Radiation Oncology, Centre Francois Baclesse, Caen (France); Salem, Naji [Radiation Oncology, Institut Paoli Calmette, Marseille (France); Mesgouez-Nebout, Nathalie [Radiation Oncology, Institut de Cancérologie de l' Ouest, Angers (France); Deniau-Alexandre, Elisabeth [Centre Hospitalier La Roche sur Yon, La Roche sur Yon (France); Rolland, Frédéric [Medical Oncology, Institut de Cancérologie de l' Ouest, Nantes (France); Ferrero, Jean-Marc [Medical Oncology, Centre Antoine Lacassagne, Nice (France); Houédé, Nadine [Medical Oncology, Institut Bergonié, Bordeaux (France); Mourey, Loïc [Institut Claudius Regaud, Toulouse (France); Théodore, Christine [Hospital Foch, Suresnes (France); Krakowski, Ivan [Centre Alexis Vautrin, Vandoeuvre-lès-Nancy (France); Berdah, Jean-François [Clinique Sainte Marguerite, Hyeres (France); Baciuchka, Marjorie [Centre Hospitalier de la Timone, Marseille (France); Laguerre, Brigitte [Centre Eugène Marquis, Rennes (France); Davin, Jean-Louis [Clinique Sainte Catherine, Avignon (France); Habibian, Muriel [R& D UNICANCER, Paris (France); UNICANCER, Paris (France); Culine, Stéphane [Department of Medical Oncology, Hopital Saint-Louis, APHP, Paris (France); and others

    2016-01-01

    Purpose: The role of pelvic elective nodal irradiation (ENI) in the management of prostate cancer is controversial. This study analyzed the role of pelvic radiation therapy (RT) on the outcome in high-risk localized prostate cancer patients included in the Groupe d'Etude des Tumeurs Uro-Genitales (GETUG) 12 trial. Methods and Materials: Patients with a nonpretreated high-risk localized prostate cancer and a staging lymphadenectomy were randomly assigned to receive either goserelin every 3 months for 3 years and 4 cycles of docetaxel plus estramustine or goserelin alone. Local therapy was administered 3 months after the start of systemic treatment. Performance of pelvic ENI was left to the treating physician. Only patients treated with primary RT were included in this analysis. The primary endpoint was biochemical progression-free survival (bPFS). Results: A total of 413 patients treated from 2002 to 2006 were included, of whom 358 were treated using primary RT. A total of 208 patients received pelvic RT and 150 prostate-only RT. Prostate-specific antigen (PSA) concentration, Gleason score, or T stage did not differ according to performance of pelvic RT; pN+ patients more frequently received pelvic RT than pN0 patients (P<.0001). Median follow-up was 8.8 years. In multivariate analysis, bPFS was negatively impacted by pN stage (hazard ratio [HR]: 2.52 [95% confidence interval [CI]: 1.78-3.54], P<.0001), Gleason score 8 or higher (HR: 1.41 [95% CI: 1.03-1.93], P=.033) and PSA higher than 20 ng/mL (HR: 1.41 [95% CI: 1.02-1.96], P=.038), and positively impacted by the use of chemotherapy (HR: 0.66 [95% CI: 0.48-0.9], P=.009). There was no association between bPFS and use of pelvic ENI in multivariate analysis (HR: 1.10 [95% CI: 0.78-1.55], P=.60), even when analysis was restricted to pN0 patients (HR: 0.88 [95% CI: 0.59-1.31], P=.53). Pelvic ENI was not associated with increased acute or late patient reported toxicity. Conclusions: This unplanned analysis of

  2. Performance of thermoluminescent materials for high dose dosimetry

    International Nuclear Information System (INIS)

    Texeira, Maria I.; Cecatti, Sonia G.P.; Caldas, Linda V.E.

    2008-01-01

    Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. The reproducibility, the lower detection limits and dose-response curves were obtained for all three materials. The different kinds of detectors show usefulness for dosimetry of workers exposed accidentally to high doses. (author)

  3. Immune reactivity after high-dose irradiation

    International Nuclear Information System (INIS)

    Gassmann, W.; Wottge, H.U.; von Kolzynski, M.; Mueller-Ruchholtz, W.

    1986-01-01

    Immune reactivity after total-body irradiation was investigated in rats using skin graft rejection as the indicator system. After sublethal irradiation with 10.5 Gy (approximately 50% lethality/6 weeks) the rejection of major histocompatibility complex allogeneic skin grafts was delayed significantly compared with nonirradiated control animals (28 versus 6.5 days). In contrast, skin grafts were rejected after 7.5 days in sublethally irradiated animals and 7 days in lethally irradiated animals if additional skin donor type alloantigens--namely, irradiated bone marrow cells--were given i.v. either simultaneously or with a delay of not more than 24 hr after the above conditioning regimen. These reactions were alloantigen-specific. They were observed in six different strain combinations with varying donors and recipients. Starting on day 2 after irradiation, i.v. injection of bone marrow gradually lost its effectivity and skin grafts were no longer rejected with uniform rapidity; skin donor marrow given on days 4 or 8 did not accelerate skin graft rejection at all. These data show that for approximately 1-2 days after high-dose total-body irradiation rats are still capable of starting a vigorous immune reaction against i.v.-injected alloantigens. The phenomenon of impaired rejection of skin grafted immediately after high-dose irradiation appears to result from the poor accessibility of skin graft alloantigens during the early postirradiation phase when vascularization of the grafted skin is insufficient

  4. High-dose vitamin C and cancer

    Directory of Open Access Journals (Sweden)

    Ahmet Unlu, M.D.

    2016-01-01

    Full Text Available Vitamin C (ascorbic acid, ascorbate is a basic compound that is of great importance with its role in various enzymatic reactions including the synthesis of collagen, as well as with its redox functions. Vitamin C has become the center of interest in cancer studies, in consequence of the facts that connective tissue changes and vitamin C deficiency were first alleged to be associated with cancer in the 1950s; and that high doses of vitamin C was asserted to be cytotoxic for cancer cells, later on. The results of the first study carried out in the 1970s were promising; but afterwards, the studies were ascertained to be faulty. Despite the positive results achieved from some laboratory and animal experiments, randomized clinical trials did not verify those findings, and no clear benefit of vitamin C for cancer treatment could be demonstrated. As for studies, where its use in combination with other cancer treatment regimens was assessed, conflicting results were obtained. Although intake of high doses of vitamin C is alleged to be harmless, based on that it is in the group of water soluble vitamins and is not stored in the body, there are many side effects and drug interactions reported in the literature. For now, it is better to abstain from this treatment, until the benefit of the treatment (if any is clearly demonstrated, considering the potential side effects and interactions.

  5. Adjuvant high dose rate vaginal cuff brachytherapy for early stage endometrial cancer

    International Nuclear Information System (INIS)

    Tannehill, S.P.; Petereit, D.G.; Schink, J.C.; Grosen, E.A.; Hartenbach, E.M.; Thomadsen, B.R.; Buchler, D.A.

    1997-01-01

    Objective: To determine the efficacy and complications of adjuvant high dose rate (HDR) vaginal cuff brachytherapy (VCB) in patients (pts) with low risk endometrial carcinoma. Materials and Methods: Since 1989, 154 patients were treated with outpatient adjuvant VCB for low risk endometrial cancer (Stage IA-14%, Stage IB-82%). Four percent of patients with stage IC disease were treated with VCB only because of medical contraindications to pelvic radiation. Patients had the following histologic grades: 53% grade 1, 40% grade 2, 5% grade 3 and 3% unknown (99%-adenocarcinoma, <1% papillary serous histology). Seventy-three percent of patients had their surgery (TAH-BSO) performed at an outside institution with minimal surgical assessment of the lymph nodes. At a median of 6 weeks after surgery, patients were treated with 2 HDR VCB insertions delivered 1 week apart. Ovoids were placed at the vaginal apex to deliver 16.2 Gy per fraction to the vaginal surface (LDR equivalent of 60 Gy at 100 cGy/h) under conscious outpatient sedation. All clinical endpoints were calculated using the Kaplan Meier method. Complications were scored using the RTOG 5-tiered system. Results: The median time in the brachytherapy suite was 60 minutes with no acute complications observed. With a median follow-up of 33 months (3-79 months), the 4-year overall and disease-free survival were 93% and 96% respectively. Five patients (3%) recurred: 2 intra-abdominally, 1 with lung metastases, and 2 in the pelvic lymph nodes. There were no vaginal cuff recurrences. The single patient with an isolated pelvic sidewall recurrence was salvaged with pelvic RT. Six patients developed a small area of asymptomatic necrosis at the vaginal cuff, which spontaneously healed at a median time of 4 months. There were no grade 3 or greater late tissue toxicities. No patient experienced significant vaginal stenosis, with 20% of the patients experiencing mild fibrosis of the vaginal apex. Conclusions: Adjuvant HDR VCB in 2

  6. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  7. Chemical dosimetry principles in high dose dosimetry

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.

    2016-01-01

    In radiation processing, activities of principal concern are process validation and process control. The objective of such formalized procedures is to establish documentary evidence that the irradiation process has achieved the desired results. The key element of such activities is inevitably a well characterized reliable dosimetry system that is traceable to recognized national and international dosimetry standards. Only such dosimetry systems can help establish the required documentary evidence. In addition, industrial radiation processing such as irradiation of foodstuffs and sterilization of health careproducts are both highly regulated, in particular with regard to dose. Besides, dosimetry is necessary for scaling up processes from the research level to the industrial level. Thus, accurate dosimetry is indispensable

  8. Onyx as radiation detector for high doses

    International Nuclear Information System (INIS)

    Teixeira, Maria Inês; Souza, Divanizia N.; Caldas, Linda V.E.

    2011-01-01

    A study of the thermoluminescent (TL) characteristics of white, black and stripped onyx samples is reported in this work. Onyx is a variety of chalcedony, a form of quartz. The onyx stone is considered nobler than marble. The irradiations were performed using a Gamma-Cell 220 system ( 60 Co). The TL emission curves presented two peaks around 150 °C and 210 °C for all samples. The dose–response curves showed a sublinear behavior between 0.5 Gy and 5 kGy, and the lower detection limit for the white onyx pellets was 1.5 mGy. The main dosimetric characteristics were studied, and the material showed good performance for high dose dosimetry.

  9. The application of high dose food irradiation

    International Nuclear Information System (INIS)

    Bruyn, I. De

    1997-01-01

    During the 1950's to end 1970's the United States Army developed the basic methodology to produce shelf stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive 'dried cooked' taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 25 to 45 kGy (depending on the product) at a temperature of between -20 and -40 Centigrade to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions. The product can be guaranteed for more than two years as long as the integrity of the packaging is maintained. (Author)

  10. The application of high dose food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bruyn, I. De [Atomic Energy Corporation of South Africa LTD, Building 2000, P.O. Box 582, Pretoria 0001, (South Africa)

    1997-12-31

    During the 1950`s to end 1970`s the United States Army developed the basic methodology to produce shelf stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive `dried cooked` taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 25 to 45 kGy (depending on the product) at a temperature of between -20 and -40 Centigrade to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions. The product can be guaranteed for more than two years as long as the integrity of the packaging is maintained. (Author)

  11. Effects of “Danzhi Decoction” on Chronic Pelvic Pain, Hemodynamics, and Proinflammatory Factors in the Murine Model of Sequelae of Pelvic Inflammatory Disease

    Directory of Open Access Journals (Sweden)

    Xiaoling Bu

    2015-01-01

    Full Text Available Objective. To evaluate the effect of Danzhi decoction (DZD on chronic pelvic pain (CPP, hemodynamics, and proinflammatory factors of sequelae of pelvic inflammatory diseases (SPID in murine model. Methods. SPID mice were randomly treated with high-dose DZD, mid-dose DZD, low-dose DZD, aspirin, and vehicle for 3 estrous circles. The Mouse Grimace Scale (MGS was performed to evaluate CPP; blood flows of the upper genital tract, pelvic wall, and mesentery were used to assess hemodynamics in SPID mice; expressions of vascular endothelial growth factor (VEGF, angiopoietin-2 (Ang-2, and osteopontin (OPN were measured by Western blot and immunochemistry. Results. Treatment with dose-dependent DZD significantly decreased the MGS scores, accelerated blood flows of the pelvis, and reduced expressions of VEGF, Ang-2, and OPN in the upper genital tract. Conclusions and Discussions. DZD was effective in relieving CPP and improving hemodynamics of the pelvic blood-stasis microenvironment in SPID mice. There was a relationship between CPP and the pelvic blood-stasis microenvironment. Furthermore, DZD might play a positive role in the anti-inflammatory process.

  12. High dose rate versus low dose rate brachytherapy in the treatment of stage IIIB cervical cancer, and the importance of brachytherapy timing

    International Nuclear Information System (INIS)

    Petereit, Daniel G.; Sarkaria, Jann N.; Czyzewski, Ann; Buchler, Dolores A.

    1996-01-01

    Purpose/Objective: To determine the efficacy of HDR versus LDR brachytherapy for Stage IIIB cervical cancer patients. Material and Methods: Forty-four HDR patients were retrospectively compared to 51 LDR patients treated at the same institution from 1977 to 1988 (LDR) and from 1989 to 1995 (HDR). A tumor burden score (TBS) of 2-9 was calculated for both groups of patients to assess volume of disease (2-4 low tumor burden, 5-9 high tumor burden). LDR and HDR patients received 60 Gy to the whole pelvis at 1.7 Gy/Fx. The majority of LDR patients were treated after completion of external beam radiation (EBR) with one 25 Gy implant to Point A (55 cGy/h). The HDR patients were treated with 4-5 HDR fractions of 3.7 Gy to 5.8 Gy/Fx for an LDR equivalence of 20-25 Gy (median dose/Fx 4.3 Gy, median insertion number 5). Clinical endpoints were calculated actuarially with significance determined by the log rank test and the relative risk (RR). Results: The median follow-up for the HDR and LDR groups was 1.8 and 5 years, respectively. Pelvic control and survival was better in the LDR group than the HDR group, 51%, 73%, 32%, 44% (p = 0.004, RR = 0.4), with grade III and above RTOG complications of 19% and 15%, respectively. The median age and performance status were similar between the two groups; however, a TBS score ≥7 was present in 23% of the HDR patients and in 9% of the LDR patients. Pelvic control in the HDR group was 58% with a TBS ≤4, and 17% with a TBS >4 (p = 0.01, RR = 0.4). The median EBR dose at the first HDR insertion was 31 Gy while all the LDR patients received 60 Gy before the insertion. Pelvic control rates in Table 1 indicate a trend towards improved outcome within the HDR group and same TBS if more external beam radiation was given prior to the first HDR insertion. Pelvic control was also higher within the HDR group when Point A received a BED Gy 10≥100 versus <100: 62%, 40%, respectively (RR 0.6). Conclusion: These retrospective results of HDR versus

  13. Limitations of high dose carrier based formulations.

    Science.gov (United States)

    Yeung, Stewart; Traini, Daniela; Tweedie, Alan; Lewis, David; Church, Tanya; Young, Paul M

    2018-06-10

    This study was performed to investigate how increasing the active pharmaceutical ingredient (API) content within a formulation affects the dispersion of particles and the aerosol performance efficiency of a carrier based dry powder inhalable (DPI) formulation, using a custom dry powder inhaler (DPI) development rig. Five formulations with varying concentrations of API beclomethasone dipropionate (BDP) between 1% and 30% (w/w) were formulated as a multi-component carrier system containing coarse lactose and fine lactose with magnesium stearate. The morphology of the formulation and each component were investigated using scanning electron micrographs while the particle size was measured by laser diffraction. The aerosol performance, in terms of aerodynamic diameter, was assessed using the British pharmacopeia Apparatus E cascade impactor (Next generation impactor). Chemical analysis of the API was observed by high performance liquid chromatography (HPLC). Increasing the concentration of BDP in the blend resulted in increasing numbers and size of individual agglomerates and densely packed BDP multi-layers on the surface of the lactose carrier. BDP present within the multi-layer did not disperse as individual primary particles but as dense agglomerates, which led to a decrease in aerosol performance and increased percentage of BDP deposition within the Apparatus E induction port and pre-separator. As the BDP concentration in the blends increases, aerosol performance of the formulation decreases, in an inversely proportional manner. Concurrently, the percentage of API deposition in the induction port and pre-separator could also be linked to the amount of micronized particles (BDP and Micronized composite carrier) present in the formulation. The effect of such dose increase on the behaviour of aerosol dispersion was investigated to gain greater insight in the development and optimisation of higher dosed carrier-based formulations. Copyright © 2018 Elsevier B.V. All

  14. Efficacy and toxicity of conventionally fractionated pelvic radiation with a hypo fractionated simultaneous versus conventionally fractionated sequential boost for patients with high-risk prostate cancer

    International Nuclear Information System (INIS)

    McDonald, Andrew M.; Jacob, Rojymon; Dobelbower, Michael C.; Kim, Robert Y.; Fiveash, John B.

    2013-01-01

    Purpose: To determine if high-risk prostate cancer responds differently to hypo fractionation. Material and methods: One hundred and fifty-seven men with NCCN high-risk (T3, PSA 20, or Gleason 8) clinically localized prostate cancer treated between 1998 and 2010 met the inclusion criteria for the analysis. Eighty-two were treated with conventional WPRT with a conventionally fractionated sequential boost to the prostate (cRT), with the prostate receiving 75-77 Gy in 1.8 - 2.0 Gy fractions. Seventy-five were treated with pelvic IMRT with a hypo fractionated simultaneous boost to the prostate (hRT), with the prostate receiving 70 Gy in 2.5 Gy fractions. The dose to the pelvic lymph nodes was 45 Gy in the cRT group and 50.4 Gy in the hRT group, both at 1.8 Gy per fraction. Ninety-two percent received neoadjuvant hormonal ablation therapy, typically beginning two months prior to the start of RT. Results: Median follow-up was 6.5 years for men receiving cRT and 3.7 years for those receiving hRT. The actuarial rate of biochemical control at four years was 88% for cRT and 94% for hRT (p=0.82). The rates of early rectal and urinary grade ≥2 toxicities were 35% (29 of 82) and 49% (40 of 82) for the cRT group and 36% (27 of 75) and 44% (33 of 75) for the hRT group. The actuarial rate of late grade 2 rectal toxicity at four years was 25% for the cRT group and 13% for the hRT group (p=0.037). The rate of late grade 3 rectal complications was 4% (3 of 82) for patients receiving cRT and 1% (1 of 75) for patients receiving hRT. Conclusion: Initial follow-up indicates equivalent biochemical control between regimens. Patients receiving hRT experienced fewer late rectal complications

  15. ELDRS Characterization for a Very High Dose Mission

    Science.gov (United States)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  16. High dose rate brachytherapy for medically inoperable stage I endometrial cancer

    Energy Technology Data Exchange (ETDEWEB)

    Petereit, Daniel G; Sarkaria, Jann N; Schink, Julian; Springman, Scott R; Kinsella, Timothy J; Buchler, Dolores A

    1995-07-01

    Purpose/Objective: To determine the efficacy of high dose rate (HDR) brachytherapy in patients with medically inoperable endometrial cancer clinically confined to the corpus. Materials and Methods: Forty-two patients with endometrial cancer and an intact uterus have been treated since 1989 with HDR brachytherapy. Twenty-six patients with medically inoperable Stage I disease were treated with radiation alone and form the basis of this study. Obesity was assessed using the body mass index (BMI kg/m{sup 2}) scale. Patients with a BMI above 28 were considered obese and those above 35 morbidly obese, per standard anesthesia guidelines. Brachytherapy was delivered in 5 HDR insertions, 1 week apart, without any external beam radiation. The following doses were delivered per insertion: 5.7 Gy to point S, 7.0 Gy to point W, 8.2 Gy to the vaginal surface and 9.2 Gy to point M. Point M represents the conventional point A dose, while points S and W are myometrial points. A single tandem with either ovoids or cylinders was placed, unless the uterine cavity would accommodate 2 tandems. All treatments were outpatient using intravenous fentanyl and midazolam for sedation. Pelvic ultrasound was commonly used at the time of brachytherapy to verify tandem placement. Three year clinical endpoints were calculated using the Kaplan Meier method. Results: The median follow-up for the study cohort was 21 months with follow-up greater than 36 months in 11 patients. Seventeen of the 26 patients were inoperable due to morbid obesity (median weight and BMI; 316 lbs and 55 kg/m{sup 2}, respectively); the other patients had poor cardiopulmonary reserve {+-} obesity. The median age, KPS (Karnofsky Performance Status), weight, ASA (American Society of Anesthesiologists' Physical Class System) and BMI were 63 yrs, 80%, 285 lbs, 3 and 49 kg/m{sup 2}, respectively. Two patients with an ASA of 3 and 4 died from acute cardio-pulmonary events within 30 days of the last insertion, emphasizing the need

  17. High dose rate brachytherapy for medically inoperable stage I endometrial cancer

    International Nuclear Information System (INIS)

    Petereit, Daniel G.; Sarkaria, Jann N.; Schink, Julian; Springman, Scott R.; Kinsella, Timothy J.; Buchler, Dolores A.

    1995-01-01

    Purpose/Objective: To determine the efficacy of high dose rate (HDR) brachytherapy in patients with medically inoperable endometrial cancer clinically confined to the corpus. Materials and Methods: Forty-two patients with endometrial cancer and an intact uterus have been treated since 1989 with HDR brachytherapy. Twenty-six patients with medically inoperable Stage I disease were treated with radiation alone and form the basis of this study. Obesity was assessed using the body mass index (BMI kg/m 2 ) scale. Patients with a BMI above 28 were considered obese and those above 35 morbidly obese, per standard anesthesia guidelines. Brachytherapy was delivered in 5 HDR insertions, 1 week apart, without any external beam radiation. The following doses were delivered per insertion: 5.7 Gy to point S, 7.0 Gy to point W, 8.2 Gy to the vaginal surface and 9.2 Gy to point M. Point M represents the conventional point A dose, while points S and W are myometrial points. A single tandem with either ovoids or cylinders was placed, unless the uterine cavity would accommodate 2 tandems. All treatments were outpatient using intravenous fentanyl and midazolam for sedation. Pelvic ultrasound was commonly used at the time of brachytherapy to verify tandem placement. Three year clinical endpoints were calculated using the Kaplan Meier method. Results: The median follow-up for the study cohort was 21 months with follow-up greater than 36 months in 11 patients. Seventeen of the 26 patients were inoperable due to morbid obesity (median weight and BMI; 316 lbs and 55 kg/m 2 , respectively); the other patients had poor cardiopulmonary reserve ± obesity. The median age, KPS (Karnofsky Performance Status), weight, ASA (American Society of Anesthesiologists' Physical Class System) and BMI were 63 yrs, 80%, 285 lbs, 3 and 49 kg/m 2 , respectively. Two patients with an ASA of 3 and 4 died from acute cardio-pulmonary events within 30 days of the last insertion, emphasizing the need for accurate pre

  18. High-dose-rate intraoperative radiation therapy: the nuts and bolts of starting a program

    Science.gov (United States)

    Moningi, Shalini; Armour, Elwood P.; Terezakis, Stephanie A.; Efron, Jonathan E.; Gearhart, Susan L.; Bivalacqua, Trinity J.; Kumar, Rachit; Le, Yi; Kien Ng, Sook; Wolfgang, Christopher L.; Zellars, Richard C.; Ellsworth, Susannah G.; Ahuja, Nita

    2014-01-01

    High-dose-rate intraoperative radiation therapy (HDR-IORT) has historically provided effective local control (LC) for patients with unresectable and recurrent tumors. However, IORT is limited to only a few specialized institutions and it can be difficult to initiate an HDR-IORT program. Herein, we provide a brief overview on how to initiate and implement an HDR-IORT program for a selected group of patients with gastrointestinal and pelvic solid tumors using a multidisciplinary approach. Proper administration of HDR-IORT requires institutional support and a joint effort among physics staff, oncologists, surgeons, anesthesiologists, and nurses. In order to determine the true efficacy of IORT for various malignancies, collaboration among institutions with established IORT programs is needed. PMID:24790628

  19. Pharmacokinetics of cephem antibiotics in exudate of pelvic retroperitoneal space after radical hysterectomy and pelvic lymphadenectomy.

    Science.gov (United States)

    Ito, K; Hayasaki, M; Tamaya, T

    1990-01-01

    Many cephalosporin antibiotics have recently been invented and attempts have been made to use them clinically. The choice of which of these drugs should be used has been difficult in gynecology. The efficacies of these drugs depend on their antibacterial spectra, potencies, and concentrations in tissues. This study was designed to investigate the pharmacokinetics of various cephem antibiotics in the exudate of the retroperitoneal space that is formed after radical hysterectomy and pelvic lymphadenectomy. These cephem antibiotics were cefoxitin, cefotiam, cefotetan, cefpiramide, cefminox, cefotaxime, ceftizoxime, cefoperazone, cefmenoxime, cefbuperazone, ceftazidime, cefpimizole, flomoxef, and cefuzonam. The maximum concentrations after administration of a 1-g dose in the exudate of the pelvic retroperitoneal space were 37.9 micrograms/ml with cefminox, 30.3 micrograms/ml with cefpimizole, 21.6 micrograms/ml with flomoxef, 21.5 micrograms/ml with ceftazidime, and 17.6 micrograms/ml with cefbuperazone, which were relatively high. When selecting antibiotics for prophylactic use against infections in the retroperitoneal space after radical hysterectomy and pelvic lymphadenectomy, on the basis of drug transfer, flomoxef, cefminox, cefbuperazone, ceftazidime, and cefpimizole were considered to be the drugs of first choice at a dose of 1 g. PMID:2393276

  20. High dose potassium-nitrate chemical dosimeter

    International Nuclear Information System (INIS)

    Dorda de Cancio, E.M.; Munoz, S.S.

    1982-01-01

    This dosimeter is used to control 10 kGY-order doses (1 Mrad). Nitrate suffers a radiolitic reduction phenomena, which is related to the given dose. The method to use potassium nitrate as dosimeter is described, as well as effects of the temperature of irradiation, pH, nitrate concentration and post-irradiation stability. Nitrate powder was irradiated at a Semi-Industrial Plant, at Centro Atomico Ezeiza, and also in a Gammacell-220 irradiator. The dose rates used were 2,60 and 1,80 KGY/hour, and the given doses varied between 1,0 and 150 KGY. The uncertainty was +-3% in all the range. (author) [es

  1. Pelvic Chondroblastoma

    International Nuclear Information System (INIS)

    Romero Rojas, Alfredo Ernesto; Restrepo Escobar, Ligia Ines; Melo Uribe, Mario Alexander

    2009-01-01

    This article describes the case of a 24-year old woman with a pelvic chondroblastoma localized at the top of the right iliac crest, with six months of evolution and progressive growth. X-rays revealed an osteolytic lesion with heterogeneous density, extending toward soft tissue; the histopathologic study provided evidence of chondroblastoma. Chondroblastomas are benign bone tumors producers of cartilage which appears in the long bone epiphysis of young people. Nearly 75% of such tumors affect the long bones, principally the femur, the tibia, and the humerus; exceptions include those in the flat craniofacial bones and the pelvis bones. Chondroblastomas have distinct radiological and histopathologic characteristics, and despite their benign biological behavior, can cause elevated morbidity among patients due to their localization and being treated exclusively with surgery.

  2. Second malignancies in high-dose areas of previous tumor radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Welte, Birgitta; Suhr, Peter; Bottke, Dirk; Bartkowiak, Detlef; Wiegel, Thomas [Dept. of Radiotherapy and Radiation Oncology, Univ. of Ulm (Germany); Doerr, Wolfgang [Dept. of Radiotherapy and Radiation Oncology, Radiobiology Lab., Univ. of Technology Dresden (Germany); Trott, Klaus Ruediger [UCL Cancer Centre, Univ. Coll. London (United Kingdom)

    2010-03-15

    Purpose: To characterize second tumors that developed in or near the high-dose areas of a previous radiotherapy, regarding their frequency, entities, latency, and dose dependence. Patients and Methods: 9,995/15,449 tumor patients of the Radiation Oncology Department in Ulm, Germany, treated between 1981 and 2003, survived at least 1 year after radiotherapy. By long-term follow-up and review of treatment documentation, 100 of them were identified who developed an independent second cancer in or near the irradiated first tumor site. Results: Major primary malignancies were breast cancer (27%), lymphoma (24%), and pelvic gynecologic tumors (17%). Main second tumors were carcinomas of the upper (18%) and lower (12%) gastrointestinal tract, head and neck tumors (10%), lymphoma (10%), breast cancer (9%), sarcoma (9%), and lung cancer (8%). Overall median second tumor latency was 7.4 years (1-42 years). For colorectal cancer it was 3.5 and for leukemia 4.3 years, but for sarcoma 11.7 and for breast cancer 17.1 years. The relatively frequent second tumors of the upper gastrointestinal tract were associated with median radiation doses of 24 Gy. By contrast, second colorectal cancer and sarcoma developed after median doses of 50 Gy. Conclusion: The 5- and 15-year probability to develop a histopathologically independent second tumor in or near the irradiated first tumor site, i.e., after intermediate or high radiation doses, was 0.5% and 2.2%, respectively. To identify potentially radiogenic second malignancies, a follow-up far beyond 5 years is mandatory. The incidence and potential dose-response relationship intermediate will be analyzed by a case-case and a case-control study of the Ulm data. (orig.)

  3. Assessment of a semiautomated pelvic floor measurement model for evaluating pelvic organ prolapse on MRI.

    Science.gov (United States)

    Onal, S; Lai-Yuen, S; Bao, P; Weitzenfeld, A; Greene, K; Kedar, R; Hart, S

    2014-06-01

    The objective of this study was to assess the performance of a semiautomated pelvic floor measurement algorithmic model on dynamic magnetic resonance imaging (MRI) images compared with manual pelvic floor measurements for pelvic organ prolapse (POP) evaluation. We examined 15 MRIs along the midsagittal view. Five reference points used for pelvic floor measurements were identified both manually and using our semiautomated measurement model. The two processes were compared in terms of accuracy and precision. The semiautomated pelvic floor measurement model provided highly consistent and accurate locations for all reference points on MRI. Results also showed that the model can identify the reference points faster than the manual-point identification process. The semiautomated pelvic floor measurement model can be used to facilitate and improve the process of pelvic floor measurements on MRI. This will enable high throughput analysis of MRI data to improve the correlation analysis with clinical outcomes and potentially improve POP assessment.

  4. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  5. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  6. High dose radiotherapy for pituitary tumours

    International Nuclear Information System (INIS)

    Mead, K.W.

    1981-01-01

    The results of treatment of 120 pituitary tumours are presented. Based on this experience operable chromophobe adenomas are now treated with 5,000 rads in 4 weeks and inoperable ones receive an additional central dose to 7,500 rads. Pituitary Cushing's tumours are given 10,000 rads in 5 weeks using small fields and acromegalics 5,000 rads to the whole sella and 7,500 to its lower half. The absence of complications at these dose levels is attributed to the use of small fields and the precise application of treatment

  7. High dose radiotherapy for pituitary tumours

    Energy Technology Data Exchange (ETDEWEB)

    Mead, K.W. (Queensland Radium Inst., Herston (Australia))

    1981-11-01

    The results of treatment of 120 pituitary tumours are presented. Based on this experience operable chromophobe adenomas are now treated with 5,000 rads in 4 weeks and inoperable ones receive an additional central dose to 7,500 rads. Pituitary Cushing's tumours are given 10,000 rads in 5 weeks using small fields and acromegalics 5,000 rads to the whole sella and 7,500 to its lower half. The absence of complications at these dose levels is attributed to the use of small fields and the precise application of treatment.

  8. Management of pelvic chondrosarcoma

    Directory of Open Access Journals (Sweden)

    Florin Groșeanu

    2016-11-01

    Full Text Available The partial or complete excision of the hemipelvis with sparing of the lower limb is an option of the treatment of pelvic chondrosarcoma and a therapeutic alternative of the interilio-abdominal disarticulation. The operation has in principle the same indications as the interilio-abdominal disarticulation and offers a good solution for avoiding a mutilating operation. The 149 cases include: 120 biopsies, 29 excisional biopsies, 6 interilioabdominal disarticulations and 14 resections – reconstruction’s, one of with prosthetic reconstruction. The prognostic score was established by assessing: the surgical stage, the site of the tumor, the surgical margins of the tumor, the functional mobility and the postoperative activity. The wide excision of the tumor, a stable reconstruction and an efficient recovery are essential for a successful treatment of pelvic chondrosarcoma. The limb sparing resection-reconstruction represents a highly surgical demanding procedure, followed up by complications in 60% of the cases, so that should be performed only by high skilled surgeons. Hemipelvectomy still remains a well-established life-saving surgery method for patients suffering from vast oncological extensions, where a pelvic resection is not an option.

  9. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  10. High dose rate brachytherapy in treatment of high grade astrocytomas

    International Nuclear Information System (INIS)

    Garcia-Alejo, R.; Delgado, J.M.; Cerro, E. del; Torres, J.J.; Martinez, R.

    1996-01-01

    From May 1994 to June 1995, 18 patients with high grade astrocytomas were entered prospectively on a selective protocol combining surgery, external beam radiotherapy, stereotactic interstitial implantation with HDR Iridium 192 and chemotherapy. Only those patients with tumor size 100cc or less average dimension, high grade astrocytoma, Karnofsky 70 or greater, unilateral, circumscribed, unifocal, tumor stable or responding to external radiation and supratentorial were included in the study. Ages ranged from 16 to 69 years. There were 13 males and 5 females. Surgery consisted of biopsy only in 3 patients, subtotal resection in 11, and gross total resection in 4 patients. Focal external beam radiation portals included the contrast enhancing mass on CT scan plus a 3 cm margin. The protocol called for minimum tumor dose of 60 Gy to be given in 2 Gy daily fractions. An interstitial brachytherapy boost was to be performed two weeks after the conclusion of external beam radiation. The dose was 30 Gy in 4 fractions. The authors analyze on basis on their personal experience, the possibilities and the limits offered by this therapeutic procedure in neuro-oncology. Using stereotactic techniques, interstitial brachytherapy of brain tumors was technically possible with negligible acute morbidity and mortality, and appeared to be effective and may provide for an increase in tumor control in selected cases

  11. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  12. Dosimetry in high dose rate endoluminal brachytherapy

    International Nuclear Information System (INIS)

    Uno, Takashi; Kotaka, Kikuo; Itami, Jun

    1994-01-01

    In endoluminal brachytherapy for the tracheobronchial tree, esophagus, and bile duct, a reference point for dose calculation has been often settled at 1 cm outside from the middle of source travel path. In the current study, a change in the ratio of the reference point dose on the convex to concave side (Dq/Dp) was calculated, provided the source travel path bends as is the case in most endoluminal brachytherapies. Point source was presumed to move stepwise at 1 cm interval from 4 to 13 locations. Retention time at each location was calculated by personal computer so as to deliver equal dose at 1 cm from the linear travel path. With the retention time remaining constant, the change of Dq/Dp was assessed by bending the source travel path. Results indicated that the length of the source travel path and radius of its curve influenced the pattern of change in Dq/Dp. Therefore, it was concluded that the difference in reference dose on the convex and concave side of the curved path is not negligible under certain conditions in endoluminal brachytherapy. In order to maintain the ratio more than 0.9, relatively greater radius was required when the source travel path was decreased. (author)

  13. Cutaneous dosimetry at low and high dose

    International Nuclear Information System (INIS)

    Martin, M.

    2009-01-01

    As radiodermatitis is a complication related to the exposure to ionizing radiation after an accidental exposition or a medical examination (radiotherapy or interventional radiology), the author briefly reports an investigation of the response of the human keratinocyte to irradiation for different dose levels, and the search for exposure markers

  14. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  15. Statistical behavior of high doses in medical radiodiagnosis; Comportamento estatistico das altas doses em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana Elisa, E-mail: adrianaebarboza@gmail.com, E-mail: elisa@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  16. measurement of high dose radiation using yellow perspex dosimeter

    International Nuclear Information System (INIS)

    Thamrin, M Thoyib; Sofyan, Hasnel

    1996-01-01

    Measurement of high dose radiation using yellow perspex dosemeter has been carried out. Dose range used was between 0.1 to 3.0 kGy. Measurement of dose rate against Fricke dosemeter as a standard dose meter From the irradiation of Fricke dosemeter with time variation of 3,6,9,12,15 and 18 minute, it was obtained average dose rate of 955.57 Gy/hour, linear equation of dose was Y= 2.333+15.776 X with its correlation factor r = 0.9999. Measurement result using yellow perspex show that correlation between net optical density and radiation dose was not linear with its equation was ODc exp. [Bo + In(dose).Bi] Value of Bo = -0.215 and Bi=0.5020. From the experiment it was suggested that routine dosimeter (yellow perspex) should be calibrated formerly against standard dosemeters

  17. Methodology of high dose research in medical radiodiagnostic

    International Nuclear Information System (INIS)

    Barboza, Adriana E.; Martins, Cintia P. de S.

    2013-01-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations

  18. Renal streaky artifact during contrast-enhanced abdominal and pelvic CT: Comparison of high versus low osmolality contrast media

    International Nuclear Information System (INIS)

    Kim, Dae Hong; Kim, Jong Chul; Lee, Chung Keun; Shin, Kyoung Suk

    1994-01-01

    Introduction of low osmolality contrast agent(LOCA) has allowed safer, more comfortable contrast-enhanced CT examination, but there has been significant increase in image degradation when evaluating the kidneys due to streaky artifact. The authors reviewed findings of contrast- enhanced abdominal and pelvic computed tomography(CT) to know the difference of renal streaky artifact between a high osmolality contrast agent (HOCA) and LOCA. This study included two hundred contrast-enhanced CT in 200 patients, 100 performed with HOCA(meglumine ioglicate, 150 ml) and 100 performed with LOCA (iopromide,150 ml). The severity of renal streaky artifact was compared between HOCA and LOCA groups. Of the scans performed with HOCA, 40 had no artifact, 52 had grade I artifact, 6 had grade II artifact, and 2 had grade III artifact. Of the scans preformed with LOCA, 23 had no artifact, 44 had grade I artifact, 29 had grade II artifact, and 4 had grade III artifact. There was significant difference in the degree of the streaky artifact depending upon the osmolality of the contrast media used(by χ 2 -test, P=.0001). The results of this study revealed a statistically significant increased incidence of artifacts and distortions of renal image with LOCA when compared with HOCA

  19. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  20. High-dose Extended-Field Irradiation and High-Dose-Rate Brachytherapy With Concurrent Chemotherapy for Cervical Cancer With Positive Para-Aortic Lymph Nodes

    International Nuclear Information System (INIS)

    Kim, Young Seok; Kim, Jong Hoon; Ahn, Seung Do; Lee, Sang-wook; Shin, Seong Soo; Nam, Joo-Hyun; Kim, Young-Tak; Kim, Yong-Man; Kim, Jong-Hyeok; Choi, Eun Kyung

    2009-01-01

    Purpose: To determine the efficacy and toxicity of extended-field radiotherapy (RT) with concurrent platinum-based chemotherapy in patients with uterine cervical carcinoma and positive para-aortic nodes. Methods and Materials: We retrospectively reviewed the results for 33 women with Stage IB-IVB cervical cancer. Each patient had received 59.4 Gy, including a three-dimensional conformal boost to the para-aortic lymph nodes and 41.4-50.4 Gy of external beam radiotherapy to the pelvis. Each patient also underwent six or seven applications of high-dose-rate brachytherapy (median, 5 Gy to point A at each session). Results: The median follow-up period of surviving patients was 39 months. The most common acute toxicity was hematologic, observed in 23 women. Severe acute and late gastrointestinal toxicity was observed in 3 and 4 patients, respectively. More than three-quarters of patients showed a complete response, encompassing the primary mass, metastatic pelvic, and para-aortic lymph nodes. Of the 33 women, 15 had no evidence of disease, 6 had persistent disease, 4 developed in-field failures, and 6 developed distant failures. The 5-year overall and disease-free survival rate was 47% and 42%, respectively. Conclusion: Concurrent chemoradiotherapy with extended-field radiotherapy is feasible in women with uterine cervical carcinoma and positive para-aortic lymph nodes, with acceptable late morbidity and a high survival rate, although it was accompanied by substantial acute toxicity.

  1. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  2. High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Was, Gary; Wirth, Brian; Motta, Athur; Morgan, Dane; Kaoumi, Djamel; Hosemann, Peter; Odette, Robert

    2018-04-30

    Project Objective: The objective of this proposal is to demonstrate the capability to predict the evolution of microstructure and properties of structural materials in-reactor and at high doses, using ion irradiation as a surrogate for reactor irradiations. “Properties” includes both physical properties (irradiated microstructure) and the mechanical properties of the material. Demonstration of the capability to predict properties has two components. One is ion irradiation of a set of alloys to yield an irradiated microstructure and corresponding mechanical behavior that are substantially the same as results from neutron exposure in the appropriate reactor environment. Second is the capability to predict the irradiated microstructure and corresponding mechanical behavior on the basis of improved models, validated against both ion and reactor irradiations and verified against ion irradiations. Taken together, achievement of these objectives will yield an enhanced capability for simulating the behavior of materials in reactor irradiations

  3. An evaluation of high-dose jobs for ALARA improvement

    International Nuclear Information System (INIS)

    Mun, J. H.; Kim, H. S.

    1997-01-01

    It is well known that about 70 percent of occupational dose have incurred from maintenance jobs at outage period. To reduce occupational dose, first, the high-dose jobs at the outage period should be identified and evaluated. For this, the database program is used, which contains the ORE data of reference plants, Kori Units 3 and 4. As a result, it is found that the jobs related to steam generator are the highest dose jobs in terms of collective ORE dose. From the analysis of the job procedures of those jobs, the ALARA improvements are also derived

  4. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  5. Acute renal failure in high dose carboplatin chemotherapy

    NARCIS (Netherlands)

    Frenkel, J.; Kool, G.; de Kraker, J.

    1995-01-01

    Carboplatin has been reported to cause acute renal failure when administered in high doses to adult patients. We report a 4 1/2-year-old girl who was treated with high-dose carboplatin for metastatic parameningeal embryonal rhabdomyosarcoma. Acute renal failure developed followed by a slow partial

  6. Pharmacogenetics and Pharmacokinetics in high-dose alkylating chemotherapy

    NARCIS (Netherlands)

    Ekhart, G.C. (Corine)

    2008-01-01

    High-dose chemotherapy in combination with peripheral blood progenitor cell transplantation has been developed as a possible curative treatment modality in several solid tumours. A frequently used high-dose regimen in the Netherlands is the CTC regimen, which is a 4-day course of cyclophosphamide,

  7. Fertility of Tall Girls Treated with High-Dose Estrogen, a Dose-Response Relationship

    NARCIS (Netherlands)

    Hendriks, A. E. J.; Drop, S. L. S.; Laven, J. S. E.; Boot, A. M.

    Context: High-dose estrogen treatment to reduce final height of tall girls increases their risk for infertility in later life. Objective: The aim was to study the effect of estrogen dose on fertility outcome of these women. Design/Setting: We conducted a retrospective cohort study of university

  8. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  9. Statistical behavior of high doses in medical radiodiagnosis

    International Nuclear Information System (INIS)

    Barboza, Adriana Elisa

    2014-01-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  10. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  11. Chronic pelvic pain.

    Science.gov (United States)

    Stein, Sharon L

    2013-12-01

    Chronic pelvic pain is pain lasting longer than 6 months and is estimated to occur in 15% of women. Causes of pelvic pain include disorders of gynecologic, urologic, gastroenterologic, and musculoskeletal systems. The multidisciplinary nature of chronic pelvic pain may complicate diagnosis and treatment. Treatments vary by cause but may include medicinal, neuroablative, and surgical treatments. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Accelerated Irradiations for High Dose Microstructures in Fast Reactor Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhijie [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-31

    The objective of this project is to determine the extent to which high dose rate, self-ion irradiation can be used as an accelerated irradiation tool to understand microstructure evolution at high doses and temperatures relevant to advanced fast reactors. We will accomplish the goal by evaluating phase stability and swelling of F-M alloys relevant to SFR systems at very high dose by combining experiment and modeling in an effort to obtain a quantitative description of the processes at high and low damage rates.

  13. Radiobiological aspects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation

    International Nuclear Information System (INIS)

    Turesson, I.

    1990-01-01

    The biological effects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation in interstitial and intracavitary radiotherapy and total body irradiation are discussed in terms of dose-rate fractionation sensitivity for various tissues. A scaling between dose-rate and fraction size was established for acute and late normal-tissue effects which can serve as a guideline for local treatment in the range of dose rates between 0.02 and 0.005 Gy/min and fraction sizes between 8.5 and 2.5 Gy. This is valid provided cell-cycle progression and proliferation can be ignored. Assuming that the acute and late tissue responses are characterized by α/β values of about 10 and 3 Gy and a mono-exponential repair half-time of about 3 h, the same total doses given with either of the two methods are approximately equivalent. The equivalence for acute and late non-hemopoietic normal tissue damage is 0.02 Gy/min and 8.5 Gy per fraction; 0.01 Gy/min and 5.5 Gy per fraction; and 0.005 Gy/min and 2.5Gy per fraction. A very low dose rate, below 0.005 Gy/min, is thus necessary to simulate high dose-rate radiotherapy with fraction sizes of about 2Gy. The scaling factor is, however, dependent on the repair half-time of the tissue. A review of published data on dose-rate effects for normal tissue response showed a significantly stronger dose-rate dependence for late than for acute effects below 0.02 Gy/min. There was no significant difference in dose-rate dependence between various acute non-hemopoietic effects or between various late effects. The consistent dose-rate dependence, which justifies the use of a general scaling factor between fraction size and dose rate, contrasts with the wide range of values for repair half-time calculated for various normal-tissue effects. This indicates that the model currently used for repair kinetics is not satisfactory. There are also few experimental data in the clinical dose-rate range, below 0.02 Gy/min. It is therefore

  14. High-temperature absorbed dose measurements in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.; Ardonceau, J.; Zuppiroli, L.

    1988-01-01

    Organic conductors of the tetraselenotetracene family have been tested as ''high-temperature'' absorbed dose dosimeters. They were heated up to 120 0 C and irradiated at this temperature with 1-MeV electrons in order to simulate, in a short time, a much longer γ-ray irradiation. The electric resistance increase of the crystal can be considered a good measurement of the absorbed dose in the range 10 6 Gy to a few 10 8 Gy and presumably one order of magnitude more. This dosimeter also permits on-line (in-situ) measurements of the absorbed dose without removing the sensor from the irradiation site. The respective advantages of organic and inorganic dosimeters at these temperature and dose ranges are also discussed. In this connection, we outline new, but negative, results concerning the possible use of silica as a high-temperature, high-dose dosimeter. (author)

  15. Pelvic haemophilic pseudotumour: management of a patient with high level of inhibitors

    International Nuclear Information System (INIS)

    Keller, A.; Terrier, F.; Schneider, P.A.; Bianchi, S.; Howarth, N.; De Moerloose, P.

    2002-01-01

    Haemophilic pseudotumour (HP) is a rare but very serious complication of haemophilia. HP affects mainly patients with severe haemophilia and those who have developed antibodies to factor VIII or factor IX. We report on a 45-year-old man with haemophilia A and high titres of inhibitors who developed an extensive HP with progressive destruction of the right ilium over a period of 12 years. The different therapeutic options (conservative management by replacement therapy, surgical approach, radiotherapy, percutaneous evacuation with secondary refilled cavity and transcatheter arterial embolization) are reviewed. (orig.)

  16. Radiophotoluminescence light scope for high-dose dosimetry

    International Nuclear Information System (INIS)

    Sato, Fuminobu; Zushi, Naoki; Sakiyama, Tomoki; Kato, Yushi; Murata, Isao; Shimizu, Kikuo; Yamamoto, Takayoshi; Iida, Toshiyuki

    2015-01-01

    A radiophotoluminescence (RPL) light scope is a remote-sensing technique for measuring in situ the radiation dose in an RPL detector placed at a distance. The RPL light scope is mainly composed of an ultraviolet (UV) pulse laser, telescopic lenses, a photomultiplier tube, and camera modules. In a performance test, some RPL detectors were placed at distances up to 30 m and were illuminated with a pulsed UV laser beam. The photoluminescence responses of the RPL detectors were analyzed using this scope. Their radiation doses were determined from the amplitude of the given component of the photoluminescence responses. The RPL readout could be repeated without fading, and its amplitude exhibited good linearity at a dose ranging from 0.1 to 60 Gy. Furthermore, a two-dimensional distribution of radiation dose was obtained by laser scanning on an RPL detector. It was confirmed that the RPL light scope was a useful remote-sensing tool for high-dose dosimetry. - Highlights: • A radiophotoluminescence (RPL) light scope was developed for high-dose dosimetry. • The RPL light scope has high sensitivity and accuracy in high-dose dosimetry. • Two-dimensional radiation dose distribution was obtained by the RPL light scope.

  17. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with

  18. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    International Nuclear Information System (INIS)

    Oliveira, Jetro Pereira de; Batista, Delano Valdivino Santos; Bardella, Lucia Helena; Carvalho, Arnaldo Rangel

    2009-01-01

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  19. High-dose dosimetry using natural silicate minerals

    International Nuclear Information System (INIS)

    Carmo, Lucas S. do; Mendes, Leticia; Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina; Barbosa, Renata F.

    2015-01-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  20. High-dose dosimetry using natural silicate minerals

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Mendes, Leticia, E-mail: isatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina, E-mail: lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear; Barbosa, Renata F., E-mail: profcelta@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil). Departamento de Ciencias do Mar

    2015-07-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  1. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Rees, M.J.; Aickin, R.; Kolbe, A.; Teele, R.L.

    2001-01-01

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  2. Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function.

    Science.gov (United States)

    Nagayama, Yasunori; Tanoue, Shota; Tsuji, Akinori; Urata, Joji; Furusawa, Mitsuhiro; Oda, Seitaro; Nakaura, Takeshi; Utsunomiya, Daisuke; Yoshida, Eri; Yoshida, Morikatsu; Kidoh, Masafumi; Tateishi, Machiko; Yamashita, Yasuyuki

    2018-05-01

    To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal-pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. We included 45 patients with renal dysfunction (estimated glomerular filtration rate  60 ml per lmin per 1.73 m 2 ) who underwent standard oncological abdominal-pelvic CT (600 mgI kg -1 , 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1-3 months after CT were measured. The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p 0.05). No significant kidney injury associated with CM administration was observed. 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.

  3. Treatment of the prostate cancer with high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Torres Silva, Felipe

    2002-01-01

    The prostate cancer treatment in early stages is controversial. The high dose rate brachytherapy has been used like monotherapy or boost with external beam radiotherapy in advanced disease. This paper describes the technique and the advantages over other modalities

  4. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    International Nuclear Information System (INIS)

    Lagisetty, Jyothi; Slovis, Thomas; Thomas, Ronald; Knazik, Stephen; Stankovic, Curt

    2012-01-01

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS <14, positive urinalysis, abdominal pain/tenderness, femur fracture) and five high-risk mechanisms of injury (unrestrained motor vehicle collision [MVC], MVC with ejection, MVC rollover, auto vs. pedestrian, auto vs. bicycle). Pelvic fractures in pediatric major blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients. (orig.)

  5. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Lagisetty, Jyothi [Memorial Hermann Medical Center, Emergency Medicine Department, Houston, TX (United States); Slovis, Thomas [Wayne State University School of Medicine, Department of Radiology, Pediatric Imaging, Children' s Hospital of Michigan, Detroit, MI (United States); Thomas, Ronald [Children' s Hospital of Michigan, Wayne State University of Medicine, Department of Pediatrics, Detroit, MI (United States); Knazik, Stephen; Stankovic, Curt [Wayne State University of Medicine, Division of Emergency Medicine, Children' s Hospital of Michigan, Detroit, MI (United States)

    2012-07-15

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS <14, positive urinalysis, abdominal pain/tenderness, femur fracture) and five high-risk mechanisms of injury (unrestrained motor vehicle collision [MVC], MVC with ejection, MVC rollover, auto vs. pedestrian, auto vs. bicycle). Pelvic fractures in pediatric major blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients. (orig.)

  6. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    International Nuclear Information System (INIS)

    Cunha, Elisete L.; Schimitberger, Thiago

    2017-01-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm -1 and 3271 cm -1 , with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  7. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Elisete L.; Schimitberger, Thiago, E-mail: elisete.cunha@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Oliveira, Cristiana M.; Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm{sup -1} and 3271 cm{sup -1}, with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  8. Braquiterapia de alta taxa de dose no Brasil High-dose rate brachytherapy in Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2004-10-01

    Full Text Available A braquiterapia de alta taxa de dose foi introduzida em nosso meio em janeiro de 1991. Desde então, houve uma mudança significativa na abordagem das neoplasias malignas em relação às vantagens do novo método, e também resolução da demanda reprimida de braquiterapia para as neoplasias ginecológicas. Nos primeiros dez anos de atividade, o Brasil tratou, em 31 serviços, 26.436 pacientes com braquiterapia, sendo mais de 50% das pacientes portadoras de neoplasias do colo uterino. Este estudo mostra o número e o perfil de pacientes tratados com esse método e a sua distribuição no território nacional, deixando explícito o benefício da braquiterapia de alta taxa de dose para o Brasil.High-dose rate brachytherapy was first introduced in Brazil in January 1991. Significant changes in the management of malignant neoplasms were observed since utilization of high-dose rate brachytherapy. The high number of gynecological patients awaiting for brachytherapy also decreased during this period. In the first ten years 26,436 patients were treated with high-dose rate brachytherapy. More than 50% of these patients presented neoplasms of the uterine cervix. In this study we present the number and profile of the patients treated with high-dose rate brachytherapy as well as the distribution of these patients in the Brazilian territory, proving the benefit of the use of high-dose rate brachytherapy in Brazil.

  9. Curative high dose rate vaginal apex brachytherapy in stage I papillary serous carcinoma of the endometrium

    International Nuclear Information System (INIS)

    Turner, B.C.; Kacinski, B.M.; Gumbs, A.; Peschel, R.E.; Haffty, B.G.; Wilson, L.D.

    1996-01-01

    Introduction: Uterine papillary serous carcinoma (UPSC) is a morphologically distinct variant of endometrial carcinoma that is associated with a poor prognosis, high recurrence rate, clinical understaging, and poor response to salvage treatment. We describe the presentation, local and distant control, survival, salvage rate, and complications for patients undergoing whole abdominal radiation therapy (WART), low dose rate (LDR) intracavitary brachytherapy, or high dose rate (HDR) vaginal brachytherapy in patients with stage I UPSC. Methods: Between 1976 and 1994 more than 1700 patients with endometrial carcinoma were treated with radiation therapy, 30 patients with stage I UPSC (1.8%) were treated with radiation before or following TAH/BSO. All patients underwent either preoperative Simon's packing or tandem and plaque which delivered 30-40 Gy to the serosa, WART, or HDR Ir-192 vaginal apex brachytherapy to a total dose of 21 Gy in 3 fractions at 0.5 cm from the vaginal mucosa. A total of 14 patients received HDR vaginal brachytherapy and (5(14)) patients received systemic chemotherapy. All patients presented with vaginal bleeding at a median age of 67 years (range 34-88). The group of 30 patients underwent TAH/BSO, 17 patients were completely staged pathologically (pelvic and para-aortic lymph nodes, omentectomy, and pelvic washings), and 2 patients underwent omental biopsy and pelvic washings only. All specimens revealed UPSC, nuclear grade 3, and lymphovascular invasion (23%). The pathologic stage was IA: 23% (7), IB: 67% (20), and IC: 10% (3). The median follow-up for all patients was 49 months (range 13-187 months). For the patients receiving postoperative HDR vaginal brachytherapy the median time from surgery to radiation was 42 days (range 29-91). Results: The 5-year actuarial disease free survival for Figo stage I UPSC patients treated with postoperative HDR vaginal brachytherapy and systemic chemotherapy was 100% compared to 74% for stage I UPSC patient

  10. Imaging pelvic floor disorders. 2. rev. ed.

    International Nuclear Information System (INIS)

    Stoker, Jaap; Taylor, Stuart A.; DeLancey, John O.L.

    2008-01-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  11. Imaging pelvic floor disorders. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Stoker, Jaap [Amsterdam Univ. (Netherlands). Dept. of Radiology; Taylor, Stuart A. [University College Hospital, London (United Kingdom). Dept. of Specialist X-Ray; DeLancey, John O.L. (eds.) [Michigan Univ., Ann Arbor, MI (United States). L4000 Women' s Hospital

    2008-07-01

    This volume builds on the success of the first edition of imaging pelvic floor disorders and is aimed at those practitioners with an interest in the imaging, diagnosis and treatment of pelvic floor dysfunction. Concise textual information from acknowledged experts is complemented by high-quality diagrams and images to provide a thorough update of this rapidly evolving field. Introductory chapters fully elucidate the anatomical basis underlying disorders of the pelvic floor. State of the art imaging techniques and their application in pelvic floor dysfunction are then discussed in detail. Additions since the first edition include consideration of the effect of aging and new chapters on perineal ultrasound, functional MRI and MRI of the levator muscles. The closing sections of the book describe the modern clinical management of pelvic floor dysfunction, including prolapse, urinary and faecal incontinence and constipation, with specific emphasis on the integration of diagnostic and treatment algorithms. (orig.)

  12. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  13. Proximity correction of high-dosed frame with PROXECCO

    Science.gov (United States)

    Eisenmann, Hans; Waas, Thomas; Hartmann, Hans

    1994-05-01

    Usefulness of electron beam lithography is strongly related to the efficiency and quality of methods used for proximity correction. This paper addresses the above issue by proposing an extension to the new proximity correction program PROXECCO. The combination of a framing step with PROXECCO produces a pattern with a very high edge accuracy and still allows usage of the fast correction procedure. Making a frame with a higher dose imitates a fine resolution correction where the coarse part is disregarded. So after handling the high resolution effect by means of framing, an additional coarse correction is still needed. Higher doses have a higher contribution to the proximity effect. This additional proximity effect is taken into account with the help of the multi-dose input of PROXECCO. The dose of the frame is variable, depending on the deposited energy coming from backscattering of the proximity. Simulation proves the very high edge accuracy of the applied method.

  14. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  15. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  16. Investigation of polymer composite for high dose dosimetry

    International Nuclear Information System (INIS)

    Pereira, E.L.M.; Batista, A.S.M.; Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H.

    2017-01-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO 2 ) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm -1 and 1730 cm -1 can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm -1 and 1730 cm -1 whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  17. Investigation of polymer composite for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, E.L.M.; Batista, A.S.M., E-mail: adriananuclear@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO{sub 2}) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm{sup -1} and 1730 cm{sup -1} can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm{sup -1} and 1730 cm{sup -1} whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  18. Gonad shielding in paediatric pelvic radiography : Disadvantages prevail over benefit

    NARCIS (Netherlands)

    Frantzen, M.J.; Robben, S.; Postma, A.A.; Zoetelief, J.; Wildberger, J.E.; Kemerink, G.J.

    2012-01-01

    Objective To re-evaluate gonad shielding in paediatric pelvic radiography in terms of attainable radiation risk reduction and associated loss of diagnostic information. Methods A study on patient dose and the quality of gonad shielding was performed retrospectively using 500 pelvic radiographs of

  19. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  20. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  1. Pelvic exenteration for locally advanced primary and recurrent pelvic neoplasm: a series of 54 resectable cases

    Directory of Open Access Journals (Sweden)

    Sergio Renato Pais Costa

    2008-09-01

    Full Text Available Objective: To report on a series of 54 patients with pelvic neoplasms submitted to curative pelvic exenteration at a tertiary hospital and describe the results (morbidity, mortality, and long-term survival. Methods: The complete data of 54 patients submitted to pelvic exenteration between 1999 and 2007 were evaluated. Sixteen men and 38 women with a mean age of 65 years and median age of 66 years (36 to 77 were studied. Surgical procedures included total pelvic exenteration (n = 26, anterior pelvic exenteration(n = 5, and posterior pelvic exenteration (n = 23. Rresults: The mean operative time was 402 minutes (280 to 585. The average volume of intraoperative bleeding was 2,013 ml (300 to 5,800. Postoperative mortality was 5% (n = 3. The overall morbidity rate was 46%(n = 25. Histological evaluation demonstrated that 47 resections were R0 (87% while seven were R1 (13%. The overall survival rate in five years was 23.5% (n = 12. Cconclusions: Despite its aggressive nature and high morbidity, pelvic exenteration is still justified in locally advanced pelvic neoplasms or even in isolated pelvic recurrence, since it affords a greater long-term control of the neoplasm.

  2. Establishment of a dosimetric system for high doses using glasses

    International Nuclear Information System (INIS)

    Correa Quezada, Valeria de la Asuncion

    1997-01-01

    A routine dosimetric system was developed using commercial glass samples. The dosimetric characteristics of national and imported samples were studied: batch uniformity, response repeatability, reutilization, absorbed dose response, detection range, response stability as a function of absorbed dose, storage temperature and thermal treatments pre- and post-irradiation, using the optical absorption technique. As an application, the dosimetric system was tested in a flower irradiation process at IPEN. All the obtained results show the usefulness of the proposed system for high dose dosimetry. (author)

  3. Pelvic and acetabular fractures

    International Nuclear Information System (INIS)

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair

  4. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  5. High dose rate brachytherapy for carcinoma of the cervix: risk factors for late rectal complications

    International Nuclear Information System (INIS)

    Uno, Takashi; Itami, Jun; Aruga, Moriyo; Kotaka, Kikuo; Fujimoto, Hajime; Minoura, Shigeki

    1996-01-01

    Purpose/Objective: To determine the incidence of late rectal complications in patients treated with high dose rate brachytherapy for FIGO stage IIB, IIIB carcinoma of the uterine cervix, and to evaluate the treatment factors associated with an increased probability of treatment complications. Materials and Methods: Records of 100 patients with FIGO IIB or IIIB cervical carcinoma treated with definitive irradiation using high dose rate intracavitary brachytherapy (HDR-ICR) between 1977 and 1994 were retrospectively reviewed. For each HDR-ICR session, 6 Gy isodose volume was reconstructed three dimensionally and the following three parameters were determined to represent this isodose volume, length (L); maximum longitudinal distance of 6 Gy isodose area in an oblique frontal plane containing the intrauterine applicator, width (W); maximum width of 6 Gy isodose area in the same plane, height (H); maximum dimension of 6 Gy isodose area perpendicular to the intrauterine applicator determined in the oblique sagittal plane. Point P/Q (2 cm ventral/dorsal from the proximal retention point of the intrauterine source) and point R/S (2 cm ventral/dorsal from the midpoint of the ovoid sources) were also defined retrospectively and HDR-ICR dose at these points were calculated. Statistical analyses were performed to determine the treatment factors predictive of late rectal complications. Results: The 5-year cumulative cause-specific disease-free survival rate was 50% for all, 74% for Stage IIB, and 38% for Stage IIIB, with a significant difference between two FIGO Stages (p=0.0004). Of patients treated for both stages, 30% and 36% had experienced moderate to severe (Grade 2-4) complications at 3 and 5 years, respectively. Average H value (p=0.013) and cumulative point S dose by HDR-ICR (p=0.020) were significantly correlated with the incidence of late rectal complications (Student's t-test), whereas these factors did not significantly affect the probability of pelvic control. No

  6. A Suspected Pelvic Aneurysmal Bone Cyst in Pregnancy

    Directory of Open Access Journals (Sweden)

    Rayan Elkattah

    2013-01-01

    Full Text Available Albeit rare, the majority of identified bone lesions in pregnancy spare the pelvis. Once encountered with a pelvic bone lesion in pregnancy, the obstetrician may face a challenging situation as it is difficult to determine and predict the effects that labor and parturition impart on the pelvic bones. Bone changes and pelvic bone fractures have been well documented during childbirth. The data regarding clinical outcomes and management of pregnancies complicated by pelvic ABCs is scant. Highly suspected to represent an aneurysmal bone cyst, the clinical evaluation of a pelvic lesion in the ilium of a pregnant individual is presented, and modes of delivery in such a scenario are discussed.

  7. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  8. Interaction of 2-Gy Equivalent Dose and Margin Status in Perioperative High-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Martinez-Monge, Rafael; Cambeiro, Mauricio; Moreno, Marta; Gaztanaga, Miren; San Julian, Mikel; Alcalde, Juan; Jurado, Matias

    2011-01-01

    Purpose: To determine patient, tumor, and treatment factors predictive of local control (LC) in a series of patients treated with either perioperative high-dose-rate brachytherapy (PHDRB) alone (Group 1) or with PHDRB combined with external-beam radiotherapy (EBRT) (Group 2). Patient and Methods: Patients (n = 312) enrolled in several PHDRB prospective Phase I-II studies conducted at the Clinica Universidad de Navarra were analyzed. Treatment with PHDRB alone, mainly because of prior irradiation, was used in 126 patients to total doses of 32 Gy/8 b.i.d. or 40 Gy/10 b.i.d. treatments after R0 or R1 resections. Treatment with PHDRB plus EBRT was used in 186 patients to total doses of 16 Gy/4 b.i.d. or 24 Gy/6 b.i.d. treatments after R0 or R1 resections along with 45 Gy of EBRT with or without concomitant chemotherapy. Results: No dose-margin interaction was observed in Group 1 patients. In Group 2 patients there was a significant interaction between margin status and 2-Gy equivalent (Eq2Gy) dose (p = 0.002): (1) patients with negative margins had 9-year LC of 95.7% at Eq2Gy = 62.9Gy; (2) patients with close margins of >1 mm had 9-year LC of 92.4% at Eq2Gy = 72.2Gy, and (3) patients with positive/close <1-mm margins had 9-year LC of 68.0% at Eq2Gy = 72.2Gy. Conclusions: Two-gray equivalent doses ≥70 Gy may compensate the effect of close margins ≥1 mm but do not counterbalance the detrimental effect of unfavorable (positive/close <1 mm) resection margins. No dose-margin interaction is observed in patients treated at lower Eq2Gy doses ≤50 Gy with PHDRB alone.

  9. Calcium carbonate as a possible dosimeter for high irradiation doses

    International Nuclear Information System (INIS)

    Negron M, A.; Ramos B, S.; Camargo R, C.; Uribe, R. M.; Gomez V, V.; Kobayashi, K.

    2014-08-01

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  10. Calcium carbonate as a possible dosimeter for high irradiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Negron M, A.; Ramos B, S.; Camargo R, C. [UNAM, Instituto de Ciencias Nucleares, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Uribe, R. M. [Kent State University, College of Technology, Kent OH (United States); Gomez V, V. [UNAM, Instituto de Quimica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Kobayashi, K., E-mail: negron@nucleares.unam.mx [Yokohama National University (Japan)

    2014-08-15

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  11. Chromosomal Aberrations in Normal and AT Cells Exposed to High Dose of Low Dose Rate Irradiation

    Science.gov (United States)

    Kawata, T.; Shigematsu, N.; Kawaguchi, O.; Liu, C.; Furusawa, Y.; Hirayama, R.; George, K.; Cucinotta, F.

    2011-01-01

    Ataxia telangiectasia (A-T) is a human autosomally recessive syndrome characterized by cerebellar ataxia, telangiectases, immune dysfunction, and genomic instability, and high rate of cancer incidence. A-T cell lines are abnormally sensitive to agents that induce DNA double strand breaks, including ionizing radiation. The diverse clinical features in individuals affected by A-T and the complex cellular phenotypes are all linked to the functional inactivation of a single gene (AT mutated). It is well known that cells deficient in ATM show increased yields of both simple and complex chromosomal aberrations after high-dose-rate irradiation, but, less is known on how cells respond to low-dose-rate irradiation. It has been shown that AT cells contain a large number of unrejoined breaks after both low-dose-rate irradiation and high-dose-rate irradiation, however sensitivity for chromosomal aberrations at low-dose-rate are less often studied. To study how AT cells respond to low-dose-rate irradiation, we exposed confluent normal and AT fibroblast cells to up to 3 Gy of gamma-irradiation at a dose rate of 0.5 Gy/day and analyzed chromosomal aberrations in G0 using fusion PCC (Premature Chromosomal Condensation) technique. Giemsa staining showed that 1 Gy induces around 0.36 unrejoined fragments per cell in normal cells and around 1.35 fragments in AT cells, whereas 3Gy induces around 0.65 fragments in normal cells and around 3.3 fragments in AT cells. This result indicates that AT cells can rejoin breaks less effectively in G0 phase of the cell cycle? compared to normal cells. We also analyzed chromosomal exchanges in normal and AT cells after exposure to 3 Gy of low-dose-rate rays using a combination of G0 PCC and FISH techniques. Misrejoining was detected in the AT cells only? When cells irradiated with 3 Gy were subcultured and G2 chromosomal aberrations were analyzed using calyculin-A induced PCC technique, the yield of unrejoined breaks decreased in both normal and AT

  12. High-dose buprenorphine: perioperative precautions and management strategies.

    Science.gov (United States)

    Roberts, D M; Meyer-Witting, M

    2005-02-01

    Buprenorphine has been in clinical use in anaesthesia for several decades. Recently, the high-dose sublingual formulation (Subutex, Reckitt Benckiser, Slough, U.K.) has been increasingly used as maintenance therapy in opioid dependence, as an alternative to methadone and other pharmacological therapies. Buprenorphine has unique pharmacological properties making it well suited for use as a maintenance therapy in opioid dependence. However, these same properties may cause difficulty in the perioperative management of pain. Buprenorphine is a partial opioid agonist, attenuating the effects of supplemental illicit or therapeutic opioid agonists. As a result of its high receptor affinity, supplemental opioids do not readily displace buprenorphine from the opioid receptor in standard doses. High-dose buprenorphine has an extended duration of action that prolongs both of these effects. The perioperative management of patients stabilized on high-dose buprenorphine and undergoing surgery requires consideration of the likely analgesic requirements. Where possible the buprenorphine should be continued. Pain management should focus on maximizing non-opioid analgesia, local anaesthesia and non-pharmacological techniques. Where pain may not be adequately relieved by these methods, the addition of a full opioid agonist such as fentanyl or morphine at appropriate doses should be considered, accompanied by close monitoring in a high dependency unit. In situations where this regimen is unlikely to be effective, preoperative conversion to morphine or methadone may be an option. Where available, liaison with a hospital-based alcohol and drug service should always be considered.

  13. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  14. Impact of Dose to the Bladder Trigone on Long-Term Urinary Function After High-Dose Intensity Modulated Radiation Therapy for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ghadjar, Pirus; Zelefsky, Michael J.; Spratt, Daniel E. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Munck af Rosenschöld, Per; Oh, Jung Hun; Hunt, Margie [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Kollmeier, Marisa [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Happersett, Laura; Yorke, Ellen; Deasy, Joseph O. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Jackson, Andrew, E-mail: jacksona@mskcc.org [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2014-02-01

    Purpose: To determine the potential association between genitourinary (GU) toxicity and planning dose–volume parameters for GU pelvic structures after high-dose intensity modulated radiation therapy in localized prostate cancer patients. Methods and Materials: A total of 268 patients who underwent intensity modulated radiation therapy to a prescribed dose of 86.4 Gy in 48 fractions during June 2004-December 2008 were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Dose–volume histograms of the whole bladder, bladder wall, urethra, and bladder trigone were analyzed. The primary endpoint for GU toxicity was an IPSS sum increase ≥10 points over baseline. Univariate and multivariate analyses were done by the Kaplan-Meier method and Cox proportional hazard models, respectively. Results: Median follow-up was 5 years (range, 3-7.7 years). Thirty-nine patients experienced an IPSS sum increase ≥10 during follow-up; 84% remained event free at 5 years. After univariate analysis, lower baseline IPSS sum (P=.006), the V90 of the trigone (P=.006), and the maximal dose to the trigone (P=.003) were significantly associated with an IPSS sum increase ≥10. After multivariate analysis, lower baseline IPSS sum (P=.009) and increased maximal dose to the trigone (P=.005) remained significantly associated. Seventy-two patients had both a lower baseline IPSS sum and a higher maximal dose to the trigone and were defined as high risk, and 68 patients had both a higher baseline IPSS sum and a lower maximal dose to the trigone and were defined as low risk for development of an IPSS sum increase ≥10. Twenty-one of 72 high-risk patients (29%) and 5 of 68 low-risk patients (7%) experienced an IPSS sum increase ≥10 (P=.001; odds ratio 5.19). Conclusions: The application of hot spots to the bladder trigone was significantly associated with relevant changes in IPSS during follow-up. Reduction of radiation dose to the lower bladder and specifically the

  15. [Studies on antimicrobial concentrations of flomoxef in serum, pelvic dead space exudate, and pelvic organs/tissues].

    Science.gov (United States)

    Obata, T; Koishi, K; Sasaki, J; Eguchi, M; Yamamoto, Y

    1987-10-01

    To women undergoing radical and total hysterectomy, flomoxef (FMOX, 6315-S) in a dose of 2 g was administered by intravenous drip infusion over 1 hour and drug concentrations in serum and pelvic dead space exudate as well as pelvic organs/tissues were determined over time. The following results were obtained: 1. Serum concentrations of FMOX after intravenous infusion showed the peak value of 92.86 +/- 17.05 micrograms/ml at the end of infusion and then gradually decreased to 29.00 +/- 10.49 micrograms/ml in 1 hour and 1.16 +/- 1.08 micrograms/ml in 6 hours. 2. Concentrations in pelvic dead space exudate, which were 6.54 +/- 3.21 micrograms/ml at the end of intravenous infusion, gradually increased to 31.28 +/- 12.69 micrograms/ml in 30 minutes, and the peak of 35.21 +/- 13.29 micrograms/ml in 1 hour. Exudate concentrations gradually decreased to 11.10 +/- 6.64 micrograms/ml at 6 hours after infusion. 3. The serum concentration at the ligature of uterine artery was 103.21 +/- 51.69 micrograms/ml. Among concentrations in pelvic organ/tissues 37.17 +/- 18.20 micrograms/ml in uterine cervix was the highest, followed by 35.77 +/- 7.68 micrograms/g in portio vaginalis, 26.35 +/- 14.15 micrograms/g in tube, 21.62 +/- 12.15 micrograms/g in ovary, 20.56 +/- 9.82 micrograms/g in myometrium, and 16.45 +/- 8.10 micrograms/g in endometrium, in this order. 4. From an analysis of the two-compartment model, the maximum serum concentration was 92.81 micrograms/ml, which was very high. The time of 50% reduction of concentration in beta phase was 1.21 hours. In the pelvic dead space exudate, the maximum concentration was 32.38 micrograms/ml and the time of 50% reduction was 2.44 hours. The AUC was 147 micrograms.hr/ml in serum and 201 micrograms.hr/ml in the pelvic dead space. The shift to the pelvic dead space was 137% when AUC's were used as the basis of the comparison. 5. Clinically, FMOX was excellently effective against adnexitis caused by Peptostreptococcus asaccharolyticus

  16. TP53 mutations in serous tubal intraepithelial carcinoma and concurrent pelvic high-grade serous carcinoma—evidence supporting the clonal relationship of the two lesions

    Science.gov (United States)

    Kuhn, Elisabetta; Kurman, Robert J; Vang, Russell; Sehdev, Ann Smith; Han, Guangming; Soslow, Robert; Wang, Tian-Li; Shih, Ie-Ming

    2016-01-01

    Serous tubal intraepithelial carcinomas (STICs) have been proposed to be the most likely precursor of ovarian, tubal and ‘primary peritoneal’ (pelvic) high-grade serous carcinoma (HGSC). As somatic mutation of TP53 is the most common molecular genetic change of ovarian HGSC, occurring in more than 95% of cases, we undertook a mutational analysis of 29 pelvic HGSCs that had concurrent STICs to demonstrate the clonal relationship of STICs and HGSCs. In addition, we correlated the mutational data with p53 immunostaining to determine the role of p53 immunoreactivity as a surrogate for TP53 mutations in histological diagnosis. Somatic TP53 mutations were detected in all 29 HGSCs analysed and the identical mutations were detected in 27 of 29 pairs of STICs and concurrent HGSCs. Missense mutations were observed in 61% of STICs and frameshift/splicing junction/nonsense mutations in 39%. Interestingly, there were two HGSCs with two distinctly different TP53 mutations each, but only one of the mutations was detected in the concurrent STICs. Missense mutations were associated with intense and diffuse (≥ 60%) p53 nuclear immunoreactivity, while most of the null mutations were associated with complete loss of p53 staining (p STIC and pelvic HGSC and demonstrate the utility of p53 immunostaining as a surrogate for TP53 mutation in the histological diagnosis of STIC. In this regard, it is important to appreciate the significance of different staining patterns. Specifically, strong diffuse staining correlates with a missense mutation, whereas complete absence of staining correlates with null mutations. PMID:21990067

  17. TP53 mutations in serous tubal intraepithelial carcinoma and concurrent pelvic high-grade serous carcinoma--evidence supporting the clonal relationship of the two lesions.

    Science.gov (United States)

    Kuhn, Elisabetta; Kurman, Robert J; Vang, Russell; Sehdev, Ann Smith; Han, Guangming; Soslow, Robert; Wang, Tian-Li; Shih, Ie-Ming

    2012-02-01

    Serous tubal intraepithelial carcinomas (STICs) have been proposed to be the most likely precursor of ovarian, tubal and 'primary peritoneal' (pelvic) high-grade serous carcinoma (HGSC). As somatic mutation of TP53 is the most common molecular genetic change of ovarian HGSC, occurring in more than 95% of cases, we undertook a mutational analysis of 29 pelvic HGSCs that had concurrent STICs to demonstrate the clonal relationship of STICs and HGSCs. In addition, we correlated the mutational data with p53 immunostaining to determine the role of p53 immunoreactivity as a surrogate for TP53 mutations in histological diagnosis. Somatic TP53 mutations were detected in all 29 HGSCs analysed and the identical mutations were detected in 27 of 29 pairs of STICs and concurrent HGSCs. Missense mutations were observed in 61% of STICs and frameshift/splicing junction/nonsense mutations in 39%. Interestingly, there were two HGSCs with two distinctly different TP53 mutations each, but only one of the mutations was detected in the concurrent STICs. Missense mutations were associated with intense and diffuse (≥ 60%) p53 nuclear immunoreactivity, while most of the null mutations were associated with complete loss of p53 staining (p STIC and pelvic HGSC and demonstrate the utility of p53 immunostaining as a surrogate for TP53 mutation in the histological diagnosis of STIC. In this regard, it is important to appreciate the significance of different staining patterns. Specifically, strong diffuse staining correlates with a missense mutation, whereas complete absence of staining correlates with null mutations. Copyright © 2012 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  18. Are routine pelvic radiographs in major pediatric blunt trauma necessary?

    Science.gov (United States)

    Lagisetty, Jyothi; Slovis, Thomas; Thomas, Ronald; Knazik, Stephen; Stankovic, Curt

    2012-07-01

    Screening pelvic radiographs to rule out pelvic fractures are routinely used for the initial evaluation of pediatric blunt trauma. Recently, the utility of routine pelvic radiographs in certain subsets of patients with blunt trauma has been questioned. There is a growing amount of evidence that shows the clinical exam is reliable enough to obviate the need for routine screening pelvic radiographs in children. To identify variables that help predict the presence or absence of pelvic fractures in pediatric blunt trauma. We conducted a retrospective study from January 2005 to January 2010 using the trauma registry at a level 1 pediatric trauma center. We analyzed all level 1 and level 2 trauma victims, evaluating history, exam and mechanism of injury for association with the presence or absence of a pelvic fracture. Of 553 level 1 and 2 trauma patients who presented during the study period, 504 were included in the study. Most of these children, 486/504 (96.4%), showed no evidence of a pelvic fracture while 18/504 (3.6%) had a pelvic fracture. No factors were found to be predictive of a pelvic fracture. However, we developed a pelvic fracture screening tool that accurately rules out the presence of a pelvic fracture P = 0.008, NPV 99, sensitivity 96, 8.98 (1.52-52.8). This screening tool combines eight high-risk clinical findings (pelvic tenderness, laceration, ecchymosis, abrasion, GCS blunt trauma can reliably be ruled out by using our pelvic trauma screening tool. Although no findings accurately identified the presence of a pelvic fracture, the screening tool accurately identified the absence of a fracture, suggesting that pelvic radiographs are not warranted in this subset of patients.

  19. Analysis of influence factors on the volume of pelvic bowel irradiated for rectal cancer

    International Nuclear Information System (INIS)

    He Yuxiang; Cai Yong; Zhu Xianggao; Han Shukui; Xu Bo

    2007-01-01

    Objective: To evaluate influence of prone/ supine position, gender, operation, bladder distension on bowel irradiated for patients with rectal cancer during pelvic radiotherapy. Methods: 36 patients with rectal cancer were investigated. Treatment plans were created with three dimensional treatment planning system. The dose and volume of bowel irradiated were analyzed according to dose-volume histograms (DVH) for every patient. The prescribed dose was 50 Gy. Results: The extent of bladder distension significantly influenced the mean doses and the V 45 high dose volumes of bowel irradiated. The treatment position and gender significantly influenced the V 15 low dose volume of bowel irradiated, the operation significantly influenced the mean doses of bowel. Either prone and supine position, or preoperative and postoperative, the doses of bowel irradiated for good bladder distension were lower and the volumes were smaller than that for bad bladder distension. The V 45 high dose volume of bowel irradiated for bad and good bladder distension at prone position were 15.3% and 7.4% (P=0.023), respectively, and at postoperative 14.1% and 7.2% (P=0.014), respectively. Conclusions: The doses and volumes of pelvic bowel irradiated were significantly influenced by the extent of bladder distension, and partly influenced by the prone/supine position, gender and operation. (authors)

  20. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  1. A novel theory of radiation damage at high doses

    International Nuclear Information System (INIS)

    Seeger, A.; Stuttgart Univ.

    1989-01-01

    Deviations of radiation damage (in the case of metals usually monitored by the residual electrical resistivity) from proportionality with the irradiation dose have so far been analysed almost exclusively in terms of extensions of models originally developed for small doses. The present theory considers the opposite limit i.e. the quasi-saturated state. It is argued that at high doses the Lueck-Sizmann effect may result in a self-organization of clusters of vacancies and self-interstitials, forming a heterogeneous froth. Possible structures of this froth and its effect on the electrical resistivity of metals are discussed. The model is shown to account for the dependence of the ''saturation resistivity'' on the nature of the irradiation as well as for several other hitherto poorly explained observations. Among them are the electrical-resistivity variation induced by high-dose irradiation with heavy ions, the amorphization of certain alloys by high-dose electron irradiation, and the occurrence of ordered arrays of stacking-fault tetrahedra after in-situ irradiations in high-voltage electron microscopes. (author)

  2. Internal hemipelvectomy with intraoperative and external beam radiotherapy in the limb-sparing treatment of a pelvic girdle chondrosarcoma

    NARCIS (Netherlands)

    Hoekstra, HJ; Szabo, BG

    The case of a patient with an extensive pelvic girdle chondrosarcoma treated with internal hemipelvectomy and intraoperative radiotherapy, followed by adjuvant high-dose external beam radiotherapy, with a successful attempt in achieving long-term local tumor control and limb-sparing treatment is

  3. Assessment of radiation doses to the para-aortic, pelvic, and inguinal lymph nodes delivered by image-guided adaptive brachytherapy in locally advanced cervical cancer

    DEFF Research Database (Denmark)

    Mohamed, Sandy M I; Aagaard, Torben; Fokdal, Lars U

    2015-01-01

    PURPOSE: This study evaluated the dose delivered to lymph nodes (LNs) by brachytherapy (BT) and the effect of BT image-guided optimization on the LN dose. METHODS AND MATERIALS: Twenty-five patients with locally advanced cervical cancer were retrospectively analyzed, 16 patients of them had LN...

  4. Radiation shielding and dose rate distribution for the building of the high dose rate accelerator

    International Nuclear Information System (INIS)

    Matsuda, Koji; Takagaki, Torao; Nakase, Yoshiaki; Nakai, Yohta.

    1984-03-01

    A high dose rate electron accelerator was established at Osaka Laboratory for Radiation Chemistry, Takasaki Establishment, JAERI in the fiscal year of 1975. This report shows the fundamental concept for the radiation shielding of the accelerator building and the results of their calculations which were evaluated through the model experiments. After the construction of the building, the leak radiation was measured in order to evaluate the calculating method of radiation shielding. Dose rate distribution of X-rays was also measured in the whole area of the irradiation room as a data base. (author)

  5. Effective dose calculation in CT using high sensitivity TLDs

    International Nuclear Information System (INIS)

    Brady, Z.; Johnston, P.N.

    2010-01-01

    Full text: To determine the effective dose for common paediatric CT examinations using thermoluminescence dosimetry (TLD) mea surements. High sensitivity TLD chips (LiF:Mg,Cu,P, TLD-IOOH, Thermo Fisher Scientific, Waltham, MA) were calibrated on a linac at an energy of 6 MY. A calibration was also performed on a superricial X-ray unit at a kilovoltage energy to validate the megavoltage cali bration for the purpose of measuring doses in the diagnostic energy range. The dose variation across large organs was assessed and a methodology for TLD placement in a 10 year old anthropomorphic phantom developed. Effective dose was calculated from the TLD measured absorbed doses for typical CT examinations after correcting for the TLD energy response and taking into account differences in the mass energy absorption coefficients for different tissues and organs. Results Using new tissue weighting factors recommended in ICRP Publication 103, the effective dose for a CT brain examination on a 10 year old was 1.6 millisieverts (mSv), 4.9 mSv for a CT chest exa ination and 4.7 mSv for a CT abdomen/pelvis examination. These values are lower for the CT brain examination, higher for the CT chest examination and approximately the same for the CT abdomen/ pelvis examination when compared with effective doses calculated using ICRP Publication 60 tissue weighting factors. Conclusions High sensitivity TLDs calibrated with a radiotherapy linac are useful for measuring dose in the diagnostic energy range and overcome limitations of output reproducibility and uniformity asso ciated with traditional TLD calibration on CT scanners or beam quality matched diagnostic X-ray units.

  6. Implementation of high-dose chemical dosimetry for industrial facilities

    International Nuclear Information System (INIS)

    Conceicao, Cirilo Cezar Sant'Anna da

    2006-01-01

    The purpose of this work is the implementation of methodology for high dose measurements using chemical dosimeters in liquid phase, traceable to the international metrology system, and make available in the country, the standard of high-dose to industrial irradiation facilities and research irradiators, trough the quality program with comparative measurements and direct use of the standard dosimeters in routine. The use of these low cost dosimetry systems in industrial irradiation facilities, assists to the certification requirements and it can reduce the costs with dosimetry for approximately 20% of the total dosimetry costs, using these systems in routine measurements and validation process, largely substituting the imported PMMA dosimeters, among others. (author)

  7. Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy

    International Nuclear Information System (INIS)

    Chu, Sung Sil; Suh, Chang Ok; Kim, Gwi Eon

    2002-01-01

    transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD(VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of 10cm in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the 30cm x 30cm 2 x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size 40 cm x 40 cm 2 and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The lead pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large field of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets reduced the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients

  8. Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Sung Sil; Suh, Chang Ok; Kim, Gwi Eon [Yonsei Univ., Seoul (Korea, Republic of)

    2002-03-15

    transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD(VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of 10cm in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the 30cm x 30cm{sup 2} x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size 40 cm x 40 cm{sup 2} and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The lead pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large field of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets reduced the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young

  9. Abnormal pelvic morphology and high cervical length are responsible for high-risk pregnancies in women displaying achondroplasia.

    Science.gov (United States)

    Vivanti, Alexandre J; Cordier, Anne-Gael; Baujat, Geneviève; Benachi, Alexandra

    2016-12-05

    Pregnancies of women displaying achondroplasia are at high risk of adverse events. Early sonographic assessment of affected women can indicate an unusually long cervical length. It is the consequence of pathological anatomy of the pelvis. Thus, there is a foreseeable dystocia owing to cephalopelvic disproportion. Furthermore, this situation could also complicate cervical ripening prior to fetal extraction.

  10. The Early Result of Whole Pelvic Radiotherapy and Stereotactic Body Radiotherapy Boost for High Risk Localized Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Yu-Wei eLin

    2014-10-01

    Full Text Available PurposeThe rationale for hypofractionated radiotherapy in the treatment of prostate cancer is based on the modern understanding of radiobiology and advances in stereotactic body radiotherapy (SBRT techniques. Whole-pelvis irradiation combined with SBRT boost for high-risk prostate cancer might escalate biologically effective dose without increasing toxicity. Here, we report our 4-year results of SBRT boost for high-risk localized prostate cancer.Methods and MaterialsFrom October 2009 to August 2012, 41 patients of newly diagnosed, high-risk or very high-risk (NCCN definition localized prostate cancer patients were treated with whole-pelvis irradiation and SBRT boost. The whole pelvis dose was 45Gy (25 fractions of 1.8Gy. The SBRT boost dose was 21 Gy (three fractions of 7 Gy. Ninety percent of these patients received hormone therapy. The toxicities of gastrointestinal (GI and genitourinary (GU tracts were scored by Common Toxicity Criteria Adverse Effect (CTCAE v3.0. Biochemical failure was defined by Phoenix definition.ResultsMedian follow-up was 42 months. Mean PSA before treatment was 44.18 ng/ml. Mean PSA level at 3, 6, 12, 18, and 24 months was 0.94, 0.44, 0.13, 0.12, and 0.05 ng/ml, respectively. The estimated 4-year biochemical failure-free survival was 91.9%. Three biochemical failures were observed. GI and GU tract toxicities were minimal. No grade 3 acute GU or GI toxicity was noted. During radiation therapy, 27% of the patient had grade 2 acute GU toxicity and 12% had grade 2 acute GI toxicity. At 3 months, most toxicity scores had returned to baseline. At the last follow up, there was no grade 3 late GU or GI toxicity.ConclusionsWhole-pelvis irradiation combined with SBRT boost for high-risk localized prostate cancer is feasible with minimal toxicity and encouraging biochemical failure-free survival. Continued accrual and follow-up would be necessary to confirm the biochemical control rate and the toxicity profiles.

  11. Characterization of Thymol blue Radiochromic dosimeters for high dose applications

    Directory of Open Access Journals (Sweden)

    Feras M. Aldweri

    2018-03-01

    Full Text Available Thymol blue (TB solutions and Thymol blue Polyvinyl Alcohol (TB-PVA films have been introduced as Radiochromic dosimeter for high dose applications. The dosimeters were irradiated with gamma ray (60Co source from 5 to 30 kGy for film, and from 0.150 kGy to 4 kGy for solution. The optical density of unirradiated and irradiated TB solution as well as TB-PVA film dosimeters were studied in terms of absorbance at 434 nm using UV/VIS spectrophotometer. The effects of scan temperature, light pre-gamma irradiation, dose rate, relative humidity and stability of the absorbance of solutions and films after irradiation were investigated. We found the dose sensitivity of TB solution and TB-PVA film dosimeters increases significantly with increases of the absorbed dose as well as with the increases of TB dye concentrations. The useful dose range of developed TB solutions and TB-PVA films dosimeters is in the range 0.125–1 kGy and of 5–20 kGy, respectively. Keywords: Dose sensitivity, Radio-chromic dosimeter, Thymol blue, Absorbance, Concentrations

  12. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  13. Safety and tolerability of high doses of glucocorticoides

    Directory of Open Access Journals (Sweden)

    Rakić Branislava D.

    2016-01-01

    Full Text Available Introduction: Treatment of acute lymphoblastic leukemia includes the use of high doses of glucocorticoides (prednisone and dexamethasone, which significantly increase the success of therapy due to lymphocytolitic effect. The aim: The aim of the study was to determine tolerability of high doses of prednisone and dexamethasone in children with acute lymphoblastic leukemia and the structure and the intensity of adverse effects, occurred after application of these medicines. Subjects and methods: In a prospective study, we analyzed adverse effects of high doses of glucocorticoides in children suffering acute lymphoblastic leukemia treated in the Institute for Child and Youth Health Care of Vojvodina, since December 2010. until October 2014, were analyzed. This study included 18 patients, aged from 2 to 15 years. Results: Hyperglycemia appeared in 89% of patients treated with prednisone and in 61% of patients treated with dexamethasone. In order to control the high blood glucose level (above 10 mmol /L, in 11% of patients insulin was used. Hypertension appeared in 28% patients treated with prednisone and dexamethasone. Antihypertensives were needed for regulation in 17% patients. Hypopotassemia and hypocalcaemia were significantly more expressed after the use of prednisone in comparison to dexamethasone. In 11% of patients, the treatment with dexamethasone caused depressive behavior, followed by agitation. Conclusion: Adverse effects of dexamethasone and prednisone, administered in high doses in children with ALL were known, expected and reversible. Adverse reactions usually disappeared spontaneously or after short-term symptomatic therapy.

  14. Low dose radiation enhance the anti-tumor effect of high dose radiation on human glioma cell U251

    International Nuclear Information System (INIS)

    Wang Chang; Wang Guanjun; Tan Yehui; Jiang Hongyu; Li Wei

    2008-01-01

    Objective: To detect the effect on the growth of human glioma cell U251 induced by low dose irradiation and low dose irradiation combined with large dose irradiation. Methods: Human glioma cell line U251 and nude mice carried with human glioma were used. The tumor cells and the mice were treated with low dose, high dose, and low dose combined high dose radiation. Cells growth curve, MTT and flow cytometry were used to detect the proliferation, cell cycle and apoptosis of the cells; and the tumor inhibition rate was used to assess the growth of tumor in vivo. Results: After low dose irradiation, there was no difference between experimental group and control group in cell count, MTT and flow cytometry. Single high dose group and low dose combined high dose group both show significantly the suppressing effect on tumor cells, the apoptosis increased and there was cell cycle blocked in G 2 period, but there was no difference between two groups. In vivo apparent anti-tumor effect in high dose radiation group and the combining group was observed, and that was more significant in the combining group; the prior low dose radiation alleviated the injury of hematological system. There was no difference between single low dose radiation group and control. Conclusions: There is no significant effect on human glioma cell induced by low dose radiation, and low dose radiation could not induce adaptive response. But in vivo experience, low dose radiation could enhance the anti-tumor effect of high dose radiation and alleviated the injury of hematological system. (authors)

  15. The influence of high doses of radiation in citrine stones

    International Nuclear Information System (INIS)

    Teixeira, M. I.; Caldas, L. V. E.

    2014-08-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  16. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  17. Multifocal Electroretinography after High Dose Chloroquine Therapy for Malaria

    Directory of Open Access Journals (Sweden)

    Aline Correa de Carvalho

    2013-01-01

    Full Text Available Purpose: To investigate changes in multifocal electroretinography (mfERG parameters associated with high dose chloroquine therapy for treatment of malaria in the Amazonia region of Brazil. Methods: Forty-eight subjects who had received chloroquine treatment for single or multiple malaria infections with a cumulative dose ranging from 1,050 to 27,000mg were included. The control group consisted of 37 healthy aged-matched subjects. Data was collected on amplitude and implicit time of the N1, P1 and N2 waves in the central macular hexagon (R1 and in five concentric rings at different retinal eccentricities (R2-R6. Results: No significant difference was observed in any mfERG parameter between chloroquine treated patients and control subjects. A comparison with previous data obtained from patients with rheumatologic disorders in the same region of Brazil who had received larger cumulative doses of chloroquine and had displayed mfERG changes, indicated that retinal toxicity seems to be dependent on cumulative dose. Conclusion: Lack of mfERG changes in the current study suggests that intensive high dose chloroquine therapy for treatment of malaria is not associated with retinal toxicity.

  18. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  19. Chronic female pelvic pain

    Directory of Open Access Journals (Sweden)

    Gaurab Maitra

    2013-01-01

    Full Text Available Chronic pelvic pain (CPP is defined as nonmalignant pain perceived in the structures related to the pelvis that has been present for more than 6 months or a non acute pain mechanism of shorter duration. Pain in the pelvic region can arise from musculoskeletal, gynaecological, urologic, gastrointestinal and or neurologic conditions. Key gynaecological conditions that contribute to CPP include pelvic inflammatory disease (PID, endometriosis, adnexa pathologies (ovarian cysts, ovarian remnant syndrome, uterine pathologies (leiomyoma, adenomyosis and pelvic girdle pain associated with pregnancy. Several major and minor sexually transmitted diseases (STD can cause pelvic and vulvar pain. A common painful condition of the urinary system is Interstitial cystitis(IC. A second urologic condition that can lead to development of CPP is urethral syndrome. Irritable bowel syndrome (IBS is associated with dysmenorrhoea in 60% of cases. Other bowel conditions contributing to pelvic pain include diverticular disease,Crohn′s disease ulcerative colitis and chronic appendicitis. Musculoskeletal pathologies that can cause pelvic pain include sacroiliac joint (SIJ dysfunction, symphysis pubis and sacro-coccygeal joint dysfunction, coccyx injury or malposition and neuropathic structures in the lower thoracic, lumbar and sacral plexus. Prolonged pelvic girdle pain, lasting more than 6 months postpartum is estimated in 3% to 30% of women. Nerve irritation or entrapment as a cause of pelvic pain can be related to injury of the upper lumbar segments giving rise to irritation of the sensory nerves to the ventral trunk or from direct trauma from abdominal incisions or retractors used during abdominal surgical procedures. Afflictions of the iliohypogastric, ilioinguinal, genitofemoral, pudendal and obturator nerves are of greatest concern in patients with pelvic pain. Patient education about the disease and treatment involved is paramount. A knowledge of the differential

  20. Postoperative vaginal cuff irradiation using high dose rate remote afterloading: a Phase II clinical protocol

    International Nuclear Information System (INIS)

    Noyes, William R.; Bastin, Kenneth; Edwards, Scott A.; Buchler, Dolores A.; Stitt, Judith A.; Thomadsen, Bruce R.; Fowler, Jack F.; Kinsella, Timothy J.

    1995-01-01

    Purpose: In September 1989, a postoperative Phase II high dose rate (HDR) brachytherapy protocol was started for International Federation of Gynecology and Obstetrics (FIGO) Stage I endometrial adenocarcinoma. This review reports the overall survival, local control, and complication rates for the initial 63 patients treated in this Phase II study. Methods and Materials: High dose rate brachytherapy was delivered using an Iridium-192 HDR remote afterloader. Sixty-three patients were entered into the Phase II protocol, each receiving two vaginal cuff treatments 1 week apart (range 4-12 days) with vaginal ovoids (diameter 2.0-3.0 cm). No patient received adjuvant external beam radiation. A dose of 32.4 Gy in two fractions was prescribed to the ovoid surface in 63 patients. The first three patients treated at our institution received 15, 16.2, and 29 Gy, respectively, to determine acute effects. Results: At a median follow-up of 1.6 years (range 0.75-4.3 years) no patient has developed a vaginal cuff recurrence. One regional recurrence (1.6%) occurred at 1.2 years at the pelvic side wall. This patient is alive and without evidence of disease 7 months after completion of salvage irradiation, which resulted in the only vaginal stenosis (1.6%). Fourteen patients (22%) experienced vaginal apex fibrosis by physical exam, which was clinically symptomatic in four patients. Two patients reported stress incontinence; however, these symptoms were noted prior to their HDR therapy. One patient died 2.4 years after HDR therapy due to cardiovascular disease without evidence of cancer at autopsy. Conclusion: Preliminary results of our phase II HDR vaginal cuff protocol for postoperative FIGO Stage IA, Grade 3 or Stage IB, Grade 1-2 patients demonstrate that 32.4 Gy in two fractions is well tolerated by the vaginal cuff mucosa. Local control appears comparable to our prior experience and others with low dose rate (LDR) brachytherapy. Additional patient accrual and further follow

  1. Use of glasses as radiation detectors for high doses

    International Nuclear Information System (INIS)

    Caldas, L.

    1989-08-01

    Glass samples were tested in relation to the possibility of use in high dose dosimetry in medical and industrial areas. The main characteristics were determined: detection threshold, reproducibility, response to gamma radiation of 137 Cs and 6 Co and thermal decay at ambient temperature, with the use of optical absorption and thermoluminesce techniques. (author) [pt

  2. Oval pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    Hoogendijk, JE; Wokke, JHJ; de Visser, M

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Sis patients responded. Side effects

  3. Oral pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    van der Meulen, M. F.; Hoogendijk, J. E.; Wokke, J. H.; de Visser, M.

    2000-01-01

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Six patients responded. Side effects

  4. High-dose acetylcysteine in idiopathic pulmonary fibrosis

    NARCIS (Netherlands)

    Demedts, Maurits; Behr, Juergen; Buhl, Roland; Costabel, Ulrich; Dekhuijzen, Richard; Jansen, Henk M.; MacNee, William; Thomeer, Michiel; Wallaert, Benoit; Laurent, François; Nicholson, Andrew G.; Verbeken, Eric K.; Verschakelen, Johny; Flower, Christopher D. R.; Capron, Frédérique; Petruzzelli, Stefano; de Vuyst, Paul; van den Bosch, Jules M. M.; Rodriguez-Becerra, Eulogio; Corvasce, Giuseppina; Lankhorst, Ida; Sardina, Marco; Montanari, Mauro

    2005-01-01

    BACKGROUND Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily) added

  5. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  6. Unusual complication and successful high-dose chemotherapy ...

    African Journals Online (AJOL)

    ... treated with high-dose chemotherapy in our institution, complicated by unusual bilateral renal vein tumour thrombi and tumour lysis syndrome. We believe this unique case highlights the need for early recognition of current and potential complications on staging computed tomography imaging, as well as successful use of ...

  7. A clinical comparison of high dose and low dose of Suxamethonium

    Directory of Open Access Journals (Sweden)

    RK Yadav

    2014-01-01

    Full Text Available Background: Suxamethonium having its rapid onset and short duration of action makes this drug unique amongst the neuromuscular blocking drugs described so far. However, use of suxamethonium is associated with a large number of undesirable side effects. Objective: To evaluate clinical effects of high and low dose of suxamethonium and to determine whether lower dose of suxamethonium can be used for any beneficial effects in terms of its various adverse effects e.g. cardiovascular responses, post-operative muscle pains and intraocular pressure. Methods: A total of 100 patients were included in this prospective study. All these patients on preoperative clinical evaluation were assessed to have adequate airway. All the patients were divided in two groups, low dose group (group I and High dose group (group II with 50 patients in each at random. A standard anesthetic technique was adhered to all the patients and following parameters were observed on comparative basis: a. Fasciculation and post operative myalgia. b. Cardiovascular effects, c. Intraocular pressure. Observation: The incidence of post Suxamethonium pain was significantly greater in group II. Increase in heart rate from baseline was significant in both groups. There was no significant difference between the two groups in the diastolic pressure but rise in systolic blood pressure was significant at all assessment times in both groups. This rise from control was statistically significant. Conclusion: Suxamethonium can be used in lower doses (0.5 mg/kg in elective cases without airway compromise. It gives benefits of reduced muscle pains, cardiovascular responses and intraocular hypertension. Journal of College of Medical Sciences-Nepal, 2013, Vol-9, No-2, 1-8 DOI: http://dx.doi.org/10.3126/jcmsn.v9i2.9677

  8. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  9. Radiation processing and high-dose dosimetry at ANSTO

    International Nuclear Information System (INIS)

    Gant, G.J.; Saunders, M.; Banos, C.; Mo, L.; Davies, J.; Evans, O.

    2001-01-01

    The Radiation Technology group at ANSTO is part of the Physics Division and provides services and advice in the areas of gamma irradiation and high-dose dosimetry. ANSTO's irradiation facilities are designed for maximum dose uniformity and provide a precision irradiation service unique in Australia. Radiation Technology makes and sells reference and transfer standard dosimeters which are purchased by users and suppliers of commercial irradiation services in Australia and the Asia-Pacific region. A calibration service is also provided for dosimeters purchased from other suppliers

  10. Australian high-dose-rate brachytherapy protocols for gynaecological malignancy

    International Nuclear Information System (INIS)

    MacLeod, C.; Dally, M.; Stevens, M.; Thornton, D.; Carruthers, S.; Jeal, P.

    2001-01-01

    There is no consensus over the optimal dose fractionation schedules for high-dose-rate (HDR) brachytherapy used for gynaecological malignancy. In Australian public hospital departments of radiation oncology, HDR brachytherapy for gynaecological cancer is being more commonly used. A survey of public departments that are using this technology, or that plan to introduce this technology, was performed. Their current protocols are presented. In general, protocols are similar biologically; however, the practical aspects such as the number of fractions given do vary and may reflect resource restrictions or, alternatively, differences in interpretations of the literature and of the best protocols by clinicians. Copyright (2001) Blackwell Science Pty Ltd

  11. Tolerance of the Brachial Plexus to High-Dose Reirradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Allen M., E-mail: achen5@kumc.edu; Yoshizaki, Taeko; Velez, Maria A.; Mikaeilian, Argin G.; Hsu, Sophia; Cao, Minsong

    2017-05-01

    Purpose: To study the tolerance of the brachial plexus to high doses of radiation exceeding historically accepted limits by analyzing human subjects treated with reirradiation for recurrent tumors of the head and neck. Methods and Materials: Data from 43 patients who were confirmed to have received overlapping dose to the brachial plexus after review of radiation treatment plans from the initial and reirradiation courses were used to model the tolerance of this normal tissue structure. A standardized instrument for symptoms of neuropathy believed to be related to brachial plexus injury was utilized to screen for toxicity. Cumulative dose was calculated by fusing the initial dose distributions onto the reirradiation plan, thereby creating a composite plan via deformable image registration. The median elapsed time from the initial course of radiation therapy to reirradiation was 24 months (range, 3-144 months). Results: The dominant complaints among patients with symptoms were ipsilateral pain (54%), numbness/tingling (31%), and motor weakness and/or difficulty with manual dexterity (15%). The cumulative maximum dose (Dmax) received by the brachial plexus ranged from 60.5 Gy to 150.1 Gy (median, 95.0 Gy). The cumulative mean (Dmean) dose ranged from 20.2 Gy to 111.5 Gy (median, 63.8 Gy). The 1-year freedom from brachial plexus–related neuropathy was 67% and 86% for subjects with a cumulative Dmax greater than and less than 95.0 Gy, respectively (P=.05). The 1-year complication-free rate was 66% and 87%, for those reirradiated within and after 2 years from the initial course, respectively (P=.06). Conclusion: The development of brachial plexus–related symptoms was less than expected owing to repair kinetics and to the relatively short survival of the subject population. Time-dose factors were demonstrated to be predictive of complications.

  12. Low grade papillary transitional cell carcinoma pelvic recurrence masquerading as high grade invasive carcinoma, ten years after radical cystectomy

    Directory of Open Access Journals (Sweden)

    Mortazavi Amir

    2008-09-01

    Full Text Available Abstract Background Tumor recurrence following radical cystectomy for a low-grade superficial transitional cell carcinoma (TCC is exceedingly uncommon and has not been reported previously. Case presentation We describe a case of a young male presenting with anorexia, weight loss and a large, painful locally destructive pelvic recurrence, ten years after radical cystoprostatectomy. The pathology was consistent with a low-grade urothelial carcinoma. After an unsuccessful treatment with cisplatin-based chemotherapy, the patient underwent a curative intent hemipelvectomy with complete excision of tumor and is disease free at one year follow-up. Conclusion A literature review related to this unusual presentation is reported and a surgical solutions over chemotherapy and radiotherapy is proposed.

  13. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.; Castro, J.R.; Chen, G.T.Y.; Collier, J.M.; Cartigny, A.; Blakely, E.A.; Lyman, J.T.; Zink, S.R.

    1985-02-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons.

  14. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    International Nuclear Information System (INIS)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.

    1985-01-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons

  15. Dimethyl sulfoxyde diethyl fumarate solution for high dose dosimetry

    International Nuclear Information System (INIS)

    Al-Kassiri, H.; Kattan, M.; Daher, Y.

    2007-06-01

    Dosimetric characterization of diethyl fumarate DEF in dimethyl sulfoxyde DMSO solution has been studied spectrophotometrically for possible application at high dose radiation dosimetry in the range (0-225 kGy). The absorption spectra of irradiated solution showed broad absorption bands between (325-400 nm) with a shoulder at 332 nm. The absorption increases as the dose is increased. Absorbance at 332 nm were measured and plotted against absorbed dose. Linear relationship and good response were found between absorbed dose and absorbance of 20% DEF concentration in the range (0-225 kGy) at the wave length, and linearity up to 250 kGy of absorbance at 332 nm .Good dose rate independence was observed in the range (14-33 kGy/h). The effect of post irradiation storage in darkness and indirect daylight conditions were not found to influence the absorption up to 700 h after irradiation. The effect of irradiation temperature within the range (0 to 60 centigrade degree) on the dosimetry performance was discussed.(author)

  16. Pulsed dose rate and fractionated high dose rate brachytherapy: choice of brachytherapy schedules to replace low dose rate treatments

    International Nuclear Information System (INIS)

    Visser, Andries G.; Aardweg, Gerard J.M.J. van den; Levendag, Peter C.

    1996-01-01

    Purpose: Pulsed dose rate (PDR) brachytherapy is a new type of afterloading brachytherapy (BT) in which a continuous low dose rate (LDR) treatment is simulated by a series of 'pulses,' i.e., fractions of short duration (less than 0.5 h) with intervals between fractions of 1 to a few hours. At the Dr. Daniel den Hoed Cancer Center, the term 'PDR brachytherapy' is used for treatment schedules with a large number of fractions (at least four per day), while the term 'fractionated high dose rate (HDR) brachytherapy' is used for treatment schedules with just one or two brachytherapy fractions per day. Both treatments can be applied as alternatives for LDR BT. This article deals with the choice between PDR and fractionated HDR schedules and proposes possible fractionation schedules. Methods and Materials: To calculate HDR and PDR fractionation schedules with the intention of being equivalent to LDR BT, the linear-quadratic (LQ) model has been used in an incomplete repair formulation as given by Brenner and Hall, and by Thames. In contrast to earlier applications of this model, both the total physical dose and the overall time were not kept identical for LDR and HDR/PDR schedules. A range of possible PDR treatment schedules is presented, both for booster applications (in combination with external radiotherapy (ERT) and for BT applications as a single treatment. Because the knowledge of both α/β values and the half time for repair of sublethal damage (T (1(2)) ), which are required for these calculations, is quite limited, calculations regarding the equivalence of LDR and PDR treatments have been performed for a wide range of values of α/β and T (1(2)) . The results are presented graphically as PDR/LDR dose ratios and as ratios of the PDR/LDR tumor control probabilities. Results: If the condition that total physical dose and overall time of a PDR treatment must be exactly identical to the values for the corresponding LDR treatment regimen is not applied, there appears

  17. High dose rate versus low dose rate interstitial radiotherapy for carcinoma of the floor of mouth

    International Nuclear Information System (INIS)

    Inoue, Takehiro; Inoue, Toshihiko; Yamazaki, Hideya; Koizumi, Masahiko; Kagawa, Kazufumi; Yoshida, Ken; Shiomi, Hiroya; Imai, Atsushi; Shimizutani, Kimishige; Tanaka, Eichii; Nose, Takayuki; Teshima, Teruki; Furukawa, Souhei; Fuchihata, Hajime

    1998-01-01

    Purpose: Patients with cancer of the floor of mouth are treated with radiation because of functional and cosmetic reasons. We evaluate the treatment results of high dose rate (HDR) and low dose rate (LDR) interstitial radiation for cancer of the floor of mouth. Methods and Materials: From January 1980 through March 1996, 41 patients with cancer of the floor of mouth were treated with LDR interstitial radiation using 198 Au grains, and from April 1992 through March 1996 16 patients with HDR interstitial radiation. There were 26 T1 tumors, 30 T2 tumors, and 1 T3 tumor. For 21 patients treated with interstitial radiation alone, a total radiation dose of interstitial therapy was 60 Gy/10 fractions/6-7 days in HDR and 85 Gy within 1 week in LDR. For 36 patients treated with a combination therapy, a total dose of 30 to 40 Gy of external radiation and a total dose of 48 Gy/8 fractions/5-6 days in HDR or 65 Gy within 1 week in LDR were delivered. Results: Two- and 5-year local control rates of patients treated with HDR interstitial radiation were 94% and 94%, and those with LDR were 75% and 69%, respectively. Local control rate of patients treated with HDR brachytherapy was slightly higher than that with 198 Au grains (p = 0.113). For late complication, bone exposure or ulcer occurred in 6 of 16 (38%) patients treated with HDR and 13 of 41 (32%) patients treated with LDR. Conclusion: HDR fractionated interstitial brachytherapy can be an alternative to LDR brachytherapy for cancer of the floor of mouth and eliminate radiation exposure for the medical staff

  18. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko; Furukawa, Souhei; Kakimoto, Naoya

    2003-01-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  19. On the genetic risk after high dose radioiodine therapy with regard to the gonadal dose

    International Nuclear Information System (INIS)

    Ehrenheim, C.; Hauswirth, C.; Fitschen, J.; Martin, E.; Oetting, G.; Hundeshagen, H.

    1997-01-01

    Aim: The genetic risk for the offspring of patients treated with high doses of radioiodine was to be assessed with special regard to the gonadal dose caused by diagnostic and therapeutic procedures. Methods: 41 young females (aged between 19 and 39 years) and four young males (aged 26 to 36 years) treated with radioiodine because of a thyroid carcinoma were interviewed by use of a questionnaire. The course of pregnancy and birth history could be documented as well as the congenital and developmental conditions of 56 children. Results: The amount of radioactivity applied for therapy and whole body scans ranged over 4,144 and 35,15 GBq I-131; the individual gonadal dose was calculated based on the MIRD model and ranged over 0,2 and 2,2 Sv (0,51 Sv at a mean). The period of time between the last radioiodine application and confinement was at least 9 months, not exceeding 14 years. As to the course of pregnancy and birth two early abortions, one extrauterine gravidity and one premature birth due to an insufficiency of the placenta were stated. In one case a chromosomal translocation 7/14 occured as a genetic defect which lead to an interruption. The children's development was unconspicuous except of two cases of neurodermatitis as well as multiple allergies and an early closure of the anterior fontanelle in one child each. Conclusion: Although the genetic risk is supposed to increase with the gonadal dose achieved (doubling dose 1 Sv) and the increased risk of any congenital anomaly was calculated as about 13% at a mean in our patients, the rate of genetic determined diseases was not elevated (1,8% or 1/57). Thus, no increase of genetic defects or congenital malformations was reported in a total of 408 children described in the literature and in our group. (orig.) [de

  20. High dose calibrations at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    McDonald, J.C.; Fox, R.A.

    1988-10-01

    The need is increasing for both high radiation exposures and calibration measurements that provide traceability of such exposures to national standards. The applications of high exposures include: electronic component damage studies, sterilization of medical products and food irradiation. Accurate high exposure measurements are difficult to obtain and cannot, in general, be carried out with a single dose measurement system or technique because of the wide range of doses and the variety of materials involved. This paper describes the dosimetric measurement and calibration techniques used at the Pacific Northwest Laboratory (PNL) that make use of radiochromic dye films, thermoluminescent dosimeters (TLDs), ionization chambers, and calorimetric dosimeters. The methods used to demonstrate the consistency of PNL calibrations with national standards will also be discussed. 4 refs

  1. Pelvic Insufficiency Fracture After Pelvic Radiotherapy for Cervical Cancer: Analysis of Risk Factors

    International Nuclear Information System (INIS)

    Oh, Dongryul; Huh, Seung Jae; Nam, Heerim; Park, Won; Han, Youngyih; Lim, Do Hoon; Ahn, Yong Chan; Lee, Jeong Won; Kim, Byoung Gie; Bae, Duk Soo; Lee, Je Ho

    2008-01-01

    Purpose: To investigate the incidence, clinical characteristics, and risk factors of pelvic insufficiency fracture (PIF) after pelvic radiotherapy (RT) in cervical cancer. Methods and Materials: Medical records and imaging studies, including bone scintigraphy, CT, and MRI of 557 patients with cervical cancer who received whole-pelvic RT between January 1998 and August 2005 were reviewed. Results: Eighty-three patients were diagnosed as having PIF after pelvic RT. The 5-year cumulative incidence of PIF was 19.7%. The most commonly involved site was the sacroiliac joint. Pelvic pain developed in 48 patients (57.8%) at diagnosis. Eleven patients (13.3%) needed admission or narcotics because of severe pain, and others had good relief of symptoms with conservative management. In univariate analysis, age ≥55 years (p < 0.001), anteroposterior/posteroanterior parallel opposing technique (p = 0.001), curative treatment (p < 0.001), and radiation dose ≥50.4 Gy (p = 0.005) were the predisposing factors for development of PIF. Concurrent chemotherapy (p = 0.78) was not significant. Multivariate analysis showed that age ≥55 years (p < 0.001), body weight <55 kg (p = 0.02), curative treatment (p = 0.03), and radiation dose ≥50.4 Gy (p = 0.04) were significant predisposing factors for development of PIF. Conclusion: The development of PIF is not rare after pelvic RT. The use of multibeam arrangements to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture, especially in elderly women with low body weight

  2. Low dose rate and high dose rate intracavitary treatment for cervical cancer

    International Nuclear Information System (INIS)

    Hareyama, Masato; Oouchi, Atsushi; Shidou, Mitsuo

    1997-01-01

    From 1984 through 1993, 144 previous untreated patients with carcinoma of uterine cervix were treated with either low dose rate 137 Cs therapy (LDR) or high dose rate 60 Co therapy (HDR). The local failure rates for more than 2-years for the primary lesions were 11.8% (8 of 63 patients) for LDR and 18.0% (11 of 61 patients). Rectal complication rates were significantly lower for HDR versus LDR (14.3% VS. 32.8%. p<0.01). Also, bladder complication rates were significantly lower for HDR versus LDR (0% VS. 10.4%, p<0.005). Treatment results in term of local control were equivalent for HDR and LDR treatment. However, the incidence of complications was higher for the LDR group than for the HDR group. (author)

  3. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  4. High-dose secondary calibration laboratory accreditation program

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1993-01-01

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program

  5. Anticoagulation and high dose liver radiation. A preliminary report

    International Nuclear Information System (INIS)

    Lightdale, C.J.; Wasser, J.; Coleman, M.; Brower, M.; Tefft, M.; Pasmantier, M.

    1979-01-01

    Two groups of patients were observed for evidence of acute radiation hepatitis during high dose radiation to the liver. The first group of 18 patients with metastatic liver disease received an average of 4,050 rad to the whole liver. Half received anticoagulation with warfarin. One patient on anticoagulation developed evidence of acute radiation hepatitis while 2 patients did so without anticoagulation. Eleven patients with Hodgkin's disease received 4,000 rad to the left lobe of the liver during extended field radiation. Four of these 11 patients were anticoagulated to therapeutic range. Only one of the fully anticoagulated patients showed changes on liver scan consistent with radiation hepatitis whereas three did so without anticoagulation. No serious sequelae from anticoagulation occurred in either group. These preliminary data suggest that anticoagulation may be safely administered with high dose hepatic radiation and that further trials with anticoagulation are warranted

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... often used to determine the cause of unexplained pain. CT scanning is fast, painless, noninvasive and accurate. ... help diagnose the cause of abdominal or pelvic pain and diseases of the internal organs, small bowel ...

  7. Chronic Pelvic Pain

    Science.gov (United States)

    ... NSAIDs) are helpful in relieving pelvic pain, especially dysmenorrhea . Physical therapy—Acupuncture, acupressure, and nerve stimulation therapies may be useful in treating pain caused by dysmenorrhea. Physical therapy that eases trigger points may give ...

  8. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... test used to help detect diseases of the small bowel, colon and other internal organs and is ... pelvic pain and diseases of the internal organs, small bowel and colon, such as: infections such as ...

  9. Pelvic Organ Prolapse

    Science.gov (United States)

    ... the Treatment Options for Pelvic Organ Prolapse? After obtaining a detailed medical history and completing a thorough ... Food and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1- ...

  10. Chronic pelvic floor dysfunction.

    Science.gov (United States)

    Hartmann, Dee; Sarton, Julie

    2014-10-01

    The successful treatment of women with vestibulodynia and its associated chronic pelvic floor dysfunctions requires interventions that address a broad field of possible pain contributors. Pelvic floor muscle hypertonicity was implicated in the mid-1990s as a trigger of major chronic vulvar pain. Painful bladder syndrome, irritable bowel syndrome, fibromyalgia, and temporomandibular jaw disorder are known common comorbidities that can cause a host of associated muscular, visceral, bony, and fascial dysfunctions. It appears that normalizing all of those disorders plays a pivotal role in reducing complaints of chronic vulvar pain and sexual dysfunction. Though the studies have yet to prove a specific protocol, physical therapists trained in pelvic dysfunction are reporting success with restoring tissue normalcy and reducing vulvar and sexual pain. A review of pelvic anatomy and common findings are presented along with suggested physical therapy management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Pelvic Inflammatory Disease (PID)

    Science.gov (United States)

    ... types of infections. Bacterial Vaginosis: A type of vaginal infection caused by the overgrowth of a number of ... of the uterus at the top of the vagina. Chlamydia: A sexually transmitted infection caused by bacteria that can lead to pelvic ...

  12. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxi...

  13. Radiotherapy and high-dose chemotherapy in advanced Ewing's tumors

    International Nuclear Information System (INIS)

    Pape, H.; Glag, M.; Gripp, S.; Wittkamp, M.; Schmitt, G.; Laws, H.J.; Kaik, B. van; Goebel, U.; Burdach, S.; Juergens, H.

    1999-01-01

    Background: Ewing's tumors are sensitive to radio- and chemotherapy. Patients with multifocal disease suffer a poor prognosis. Patients presenting primary bone marrow involvement or bone metastases at diagnosis herald a 3-year disease-free survival below 15%. The European Intergroup Cooperative Ewing's Sarcoma Study (EICESS) has established the following indications for high-dose therapy in advanced Ewing's tumors: Patients with primary multifocal bone disease, patients with early ( [de

  14. Pelvic endometriosis: a comparison between low-field (0.2 T) and high-field (1.5 T) magnetic resonance imaging

    International Nuclear Information System (INIS)

    Minaif, Karine; Ajzen, Sergio; Shigueoka, David Carlos; Minami, Cintia Cristina Satie; Sales, Danilo Moulin; Szejnfeld, Jacob; Ruano, Jose Maria Cordeiro; Noguti, Alberto Sinhiti

    2008-01-01

    Objective: to compare low-field (0.2 T) with high-field (1.5 T) magnetic resonance imaging in the assessment of pelvic endometriosis and adenomyosis. Materials and methods: twenty-seven female patients with clinically suspected endometriosis were prospectively evaluated by means of high-field and low-field magnetic resonance imaging. The reading of the images was performed by a single radiologist, initiating by the low-field, followed by the high-field images. High-field magnetic resonance imaging was utilized as the golden-standard. Results: among the 27 patients included in the present study, 18 (66.7%) had some type of lesion suggesting the presence of endometriosis demonstrated at high-field images. In 14 of these patients the diagnosis was correctly established by low-field magnetic resonance imaging. Endometriomas, tubal lesions, and endometriotic foci > 7 mm identified at the high-field images were also identified at low-field images with 100% accuracy, sensitivity and specificity. Among the nine patients diagnosed with adenomyosis by high-field images, eight were correctly diagnosed by low-field images with 88.9% accuracy, specificity and sensitivity. Conclusion: low-field magnetic resonance imaging demonstrated a low sensitivity in the detection of small endometriotic foci, high sensitivity in the detection of endometriomas and large endometriotic foci, and high accuracy in the detection of adenomyosis when compared with high-field magnetic resonance imaging. (author)

  15. Pelvic endometriosis: a comparison between low-field (0.2 T) and high-field (1.5 T) magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minaif, Karine; Ajzen, Sergio [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis]. E-mail: kminaif@uol.com.br; Shigueoka, David Carlos; Minami, Cintia Cristina Satie; Sales, Danilo Moulin; Szejnfeld, Jacob [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis. Unit of Abdomen; Ruano, Jose Maria Cordeiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of General Gynecology. Sector of Videlaparoscopy; Noguti, Alberto Sinhiti [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of General Gynecology

    2008-11-15

    Objective: to compare low-field (0.2 T) with high-field (1.5 T) magnetic resonance imaging in the assessment of pelvic endometriosis and adenomyosis. Materials and methods: twenty-seven female patients with clinically suspected endometriosis were prospectively evaluated by means of high-field and low-field magnetic resonance imaging. The reading of the images was performed by a single radiologist, initiating by the low-field, followed by the high-field images. High-field magnetic resonance imaging was utilized as the golden-standard. Results: among the 27 patients included in the present study, 18 (66.7%) had some type of lesion suggesting the presence of endometriosis demonstrated at high-field images. In 14 of these patients the diagnosis was correctly established by low-field magnetic resonance imaging. Endometriomas, tubal lesions, and endometriotic foci > 7 mm identified at the high-field images were also identified at low-field images with 100% accuracy, sensitivity and specificity. Among the nine patients diagnosed with adenomyosis by high-field images, eight were correctly diagnosed by low-field images with 88.9% accuracy, specificity and sensitivity. Conclusion: low-field magnetic resonance imaging demonstrated a low sensitivity in the detection of small endometriotic foci, high sensitivity in the detection of endometriomas and large endometriotic foci, and high accuracy in the detection of adenomyosis when compared with high-field magnetic resonance imaging. (author)

  16. Dose characteristics of high-energy electrons, muons and photons

    International Nuclear Information System (INIS)

    Britvich, G.I.; Krupnyj, G.I.; Peleshko, V.N.; Rastsvetalov, Ya.N.

    1980-01-01

    Differential distribution of energy release at different depth of tissue-equivalent phantoms (plexiglas, polystyrene, polyethylene) at the energy of incident electrons, muons of 0.2-40 GeV and photons with the mean energy of 3.6 GeV are measured. The error of experimental results does not exceed 7%. On the basis of the data obtained dose characteristics of electrons, muons and photons for standard geometry are estimated. For all types of irradiation the maximum value of specific equivalent dose, nremxcm 2 /part. is presented. It is shown that published values of specific equivalent dose of electron radiation are higher in all the investigated energy range from 0.2 to 40 GeV, and for muon radiation a good agreement with the present experiment is observed. The highly precise results obtained which cover the wide dynamic range according to the energy of incident particles can serve as the basis for reconsidering the existing recommendations for dose characteristics of electron radiation [ru

  17. Ion exchange resins as high-dose radiation dosimeters

    International Nuclear Information System (INIS)

    Alian, A.; Dessouki, A.; El-Assay, N.B.

    1984-01-01

    This paper reports on the possibility of using various types of ion exchange resins as high-dose radiation dosimeters, by analysis of the decrease in exchange capacity with absorbed dose. The resins studied are Sojuzchim-export-Moscow Cation Exchanger KU-2 and Anion Exchanger AV-17 and Merck Cation Exchanger I, and Merck Anion Exchangers II and III. Over the dose range 1 to 100 kGy, the systems show linearity between log absorbed dose and decrease in resin ion exchange capacity. The slope of this response function differs for the different resins, depending on their ionic form and degree of cross-linking. The radiation sensitivity increases in the order KU-2; Exchanger I; AV-17; Exchanger II; Exchanger III. Merck resins with moisture content of 21% showed considerably higher radiation sensitivity than those with 2 to 3% moisture content. The mechanism of radiation-induced denaturing of the ion exchanger resins involves cleavage and decomposition of functional substituents, with crosslinking playing a stabilizing role, with water and its radiolytic products serving to inhibit radical recombination and interfering with the protection cage effect of crosslinking. (author)

  18. PLUTONIUM/HIGH-LEVEL VITRIFIED WASTE BDBE DOSE CALCULATION

    Energy Technology Data Exchange (ETDEWEB)

    J.A. Ziegler

    2000-11-20

    The purpose of this calculation is to provide a dose consequence analysis of high-level waste (HLW) consisting of plutonium immobilized in vitrified HLW to be handled at the proposed Monitored Geologic Repository at Yucca Mountain for a beyond design basis event (BDBE) under expected conditions using best estimate values for each calculation parameter. In addition to the dose calculation, a plutonium respirable particle size for dose calculation use is derived. The current concept for this waste form is plutonium disks enclosed in cans immobilized in canisters of vitrified HLW (i.e., glass). The plutonium inventory at risk used for this calculation is selected from Plutonium Immobilization Project Input for Yucca Mountain Total Systems Performance Assessment (Shaw 1999). The BDBE examined in this calculation is a nonmechanistic initiating event and the sequence of events that follow to cause a radiological release. This analysis will provide the radiological releases and dose consequences for a postulated BDBE. Results may be considered in other analyses to determine or modify the safety classification and quality assurance level of repository structures, systems, and components. This calculation uses best available technical information because the BDBE frequency is very low (i.e., less than 1.0E-6 events/year) and is not required for License Application for the Monitored Geologic Repository. The results of this calculation will not be used as part of a licensing or design basis.

  19. The spectrum of pelvic fracture urethral injuries and posterior urethroplasty in an Italian high-volume centre, from 1980 to 2013.

    Science.gov (United States)

    Barbagli, Guido; Sansalone, Salvatore; Romano, Giuseppe; Lazzeri, Massimo

    2015-03-01

    To describe the emergency and delayed treatment of patients with pelvic fracture urethral injuries (PFUI) presenting to an Italian high-volume centre. In a retrospective, observational study we evaluated the spectrum of PFUI and posterior urethroplasty in an Italian high-volume centre, from 1980 to 2013. Patients requiring emergency treatment for PFUI and delayed treatment for pelvic fracture urethral defects (PFUD) were included. Patients with incomplete clinical records were excluded from the study. Descriptive statistical methods were applied. In all, 159 male patients (median age 35 years) were included in the study. A traffic accident was the most frequent (42.8%) cause of PFUI, and accidents at work were reported as the cause of trauma in 34% of patients. Agricultural accidents decreased from 24.4% to 6.2% over the course of the survey. A suprapubic cystostomy was the most frequent (49%) emergency treatment in patients with PFUI. The use of surgical realignment decreased from 31.7% to 6.2%, and endoscopic realignment increased from 9.7% to 35.3%. A bulbo-prostatic anastomosis was the most frequent (62.9%) delayed treatment in patients with PFUD. The use of the Badenoch pull-through decreased from 19.5% to 2.6%, and endoscopic holmium laser urethrotomy increased from 4.9% to 32.7%. The spectrum of PFUI and subsequent treatment of PFUD has changed greatly over the last 10 years at our centre. These changes involved patient age, aetiology, emergency and delayed treatments, and were found to be related to changes in the economy and lifestyle of the Italian patients.

  20. Establishment and verification of dose-response curve of chromosomal aberrations after exposure to very high dose γ-ray

    International Nuclear Information System (INIS)

    Chen Ying; Luo Yisheng; Cao Zhenshan; Liu Xiulin

    2006-01-01

    To estimate accurately biological dose of the victims exposed to high dose, the dose-response curves of chromosome aberration induced by 6-22 Gy 60 Co γ-ray were established. Human peripheral blood in vitro was irradiated, then lymphocytes were concentrated, cultured 52h, 68h and 72h and harvested. The frequencies of dicentrics (multi-centrics) and rings were counted and compared between different culture times. The dose-response curves and equations were established, as well as verified with high dose exposure accidents. The experiment showed that the culture time should be prolonged properly after high dose exposure, and no significant differences were observed between 52-72h culture. The dose-response curve of 6-22 Gy fitted to linear-square model Y=-2.269 + 0.776D - 7.868 x 10 -3 D 2 and is reliable through verification of the accident dose estimations. In this study, the dose-response curve and equation of chromosome dic + r after 6-22 Gy high dose irradiation were established firstly, and exact dose estimation can be achieved according to it. (authors)

  1. Survey on patient doses in cardiology in Latin America. Criteria for high skin doses follow up

    International Nuclear Information System (INIS)

    Duran, Ariel; Duro, Ivanna; Lopez, Leonardo; Ramirez, Alfredo; Herrera, Carlos; Navarro, Joaquin; Rivarola, Carlos; Lopez, Jose A.

    2008-01-01

    Full text: As part of the International Action Plan for Protection of Patients and supporting by the IAEA, a survey on patient doses in fluoroscopy guided procedures in cardiology in Latin America has been conducted since 2006. One of the objectives of the survey was to set criteria for the identification and evaluation of high skin doses in a certain number of patients to recommend a clinical follow up for potential radiation injuries (more than 3 Gy at the skin). The used methodology for the survey was initiated with two dedicated workshops held in Santiago de Chile (2005) and San Jose de Costa Rica (2007) involving relevant cardiologists from 15 different Latin American Countries. Some sessions were also attended by experts from the Regulatory and Health Authorities. Standardized forms to collect demographic and patient dosimetric data were agreed. Considering that most of the involved centres had still not dosimeters installed in the cardiology x-ray systems, it was agreed to collect data on fluoroscopy time and total number of cine frames per procedure. Relevant factors influencing radio sensitivity of the skin were also collected. Data from 10 countries representing a sample of 709 patients were received during the first year. Procedures included were diagnostic (DG) (coronary angiography and electrophysiology studies), therapeutic (TH) (percutaneous transluminal coronary angioplasties, cardiac ablations and valvuloplasties) or including both DG and TH. A total of 26 patients (3.7%) were selected for potential high skin doses. Initial considered criteria for selection were more than 30 minutes of fluoroscopy, more than 3,000 cine frames per procedure or patients with more than 100 kg of weight. Maximum reported values were 72 minutes and 8,100 frames. In addition, 5 of these patients were diabetic, 6 have previous fluoroscopy procedures and 5 were over 95 kg. The percentage of selected cases for clinical follow up derived from potential skin injuries seem

  2. Anorectal and Pelvic Pain.

    Science.gov (United States)

    Bharucha, Adil E; Lee, Tae Hee

    2016-10-01

    Although pelvic pain is a symptom of several structural anorectal and pelvic disorders (eg, anal fissure, endometriosis, and pelvic inflammatory disease), this comprehensive review will focus on the 3 most common nonstructural, or functional, disorders associated with pelvic pain: functional anorectal pain (ie, levator ani syndrome, unspecified anorectal pain, and proctalgia fugax), interstitial cystitis/bladder pain syndrome, and chronic prostatitis/chronic pelvic pain syndrome. The first 2 conditions occur in both sexes, while the latter occurs only in men. They are defined by symptoms, supplemented with levator tenderness (levator ani syndrome) and bladder mucosal inflammation (interstitial cystitis). Although distinct, these conditions share several similarities, including associations with dysfunctional voiding or defecation, comorbid conditions (eg, fibromyalgia, depression), impaired quality of life, and increased health care utilization. Several factors, including pelvic floor muscle tension, peripheral inflammation, peripheral and central sensitization, and psychosocial factors, have been implicated in the pathogenesis. The management is tailored to symptoms, is partly supported by clinical trials, and includes multidisciplinary approaches such as lifestyle modifications and pharmacological, behavioral, and physical therapy. Opioids should be avoided, and surgical treatment has a limited role, primarily in refractory interstitial cystitis. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  3. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva; Yoriyaz, Hélio; Tedgren, Åsa Carlsson; Nilsson, Josef; Persson, Maria; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (D m,m ) and dose-to-water-in-medium (D w,m ). The relation between D m,m and D w,m for 192 Ir is the main goal of this study, in particular the dependence of D w,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: D m,m, D w,m (LCT), mean photon energy and photon fluence. D w,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between D m,m and D w,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between D w,m (SCT) and D w,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between D m,m and D w,m (SCT) mainly depend on tissue type, differences between D m,m and D w,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources. (paper)

  4. Preoperative evaluation of locally spreaded pelvic tumors

    International Nuclear Information System (INIS)

    Baramia, M.; Todua, F.; Gotsadze, D.; Khutulashvili, N.; Lashkhi, K.; Nadareishvili, A.

    1998-01-01

    Am of the study: preoperative evaluation of patients with locally advanced pelvic tumors subjected to pelvic exenteration. Determine operability to avoid explorative laparatomies, which cause serious complications in these patients. Evaluate condition of urinary system in case of this pathology. Materials and methods: 34 patients with locally advanced pelvic tumors where pelvic exenteration was attempted were studied. Along with other methods of diagnostic CT and MRI were performed. Results: In all patients secondary involvement of the urinary bladder was noted. In 30 patients CT and MR findings were confirmed (88,2%) intraoperatively and different types of pelvic organs exenteration were performed. In 1 case spread of tomoruos infiltrate to the pelvic wall and common iliac vessels was detected intraoperatively (patient had history of radiation therapy). In 2 cases carcinomatosis of the peritoneum was found. In 1 case involvement of urinary bladder was simulated by close attachment of enlarged uterus. Conclusion: Obtained results show, that CT and MR are highly informative methods of disease spread evaluation and thus determining operability. Radiotherapy performed prior to operation sets difficulties in differentiation for tumourous infiltrate and post-radiotherapy changes in pelvis. (Full text)

  5. High dose vitamin K3 infusion in advanced hepatocellular carcinoma.

    Science.gov (United States)

    Sarin, Shiv K; Kumar, Manoj; Garg, Sanjay; Hissar, Syed; Pandey, Chandana; Sharma, Barjesh C

    2006-09-01

    The survival of patients with unresectable advanced hepatocellular carcinoma (HCC) with portal vein thrombosis is dismal. Current therapeutic options have limited efficacy. Vitamin K has been shown to have antitumor effect on HCC cells both in cell lines and patients with advanced HCC. The aim of this study was to assess the clinical efficacy of high dose vitamin K3 in the treatment of advanced HCC with portal vein thrombosis. Forty-two consecutive patients with advanced HCC (Stage C according to BCLC staging system) with portal vein thrombosis were randomized into two groups: (i) high dose vitamin K3 (n = 23); and (ii) placebo (n = 19). The vitamin K3 was administered by i.v. infusion of 50 mg/day with daily increase of dose by 50 mg for 6 days, followed by 20 mg i.m. twice daily for 2 weeks. Of the 23 patients treated with vitamin K, one (4.3%) achieved complete response and three (13%) partial response, for a total of four (17.4%) objective responders overall. The overall mean survival was 8.9 +/- 8.8 months (median: 6; range 1-37 months) in the vitamin K group and 6.8 +/- 5.3 months (median: 5; range 1.5-21 months) in the placebo group (P = 0.552). The mean duration of survival was longer in patients in the vitamin K group who achieved objective response (22.5 +/- 12.2; median: 21; range 11-37 months) as compared to patients not achieving objective response (6.1 +/- 4.6; median: 5; range 1-16 months) (P = 0.0.002). Portal vein thrombosis resolved with complete patency in one (4.35%) patient. Treatment with high dose vitamin K produces objective response in 17% patients with improved survival in patients achieving objective response; however, it does not affect the overall survival.

  6. High-dose preoperative radiation for cancer of the rectum: Impact of radiation dose on patterns of failure and survival

    International Nuclear Information System (INIS)

    Ahmad, N.R.; Mohiuddin, M.; Marks, G.

    1993-01-01

    A variety of dose-time schedules are currently used for preoperative radiation therapy of rectal cancer. An analysis of patients treated with high-dose preoperative radiation therapy was undertaken to determine the influence of radiation dose on the patterns of failure, survival, and complications. Two hundred seventy-five patients with localized rectal cancer were treated with high-dose preoperative radiation therapy. One hundred fifty-six patients received 45 Gy (low-dose group). Since 1985, 119 patients with clinically unfavorable cancers were given a higher dose, 55 Gy using a shrinking field technique (high-dose group). All patients underwent curative resection. Median follow-up was 66 months in the low-dose group and 28 months in the high-dose group. Patterns of failure, survival, and complications were analyzed as a function of radiation dose. Fourteen percent of the total group developed a local recurrence; 20% in the low-dose group as compared with 6% in the high-dose group. The actuarial local recurrence rate at 5 years was 20% for the low-dose group and 8% for the high-dose group, and approached statistical significance with p = .057. For tethered/fixed tumors the actuarial local recurrence rates at 5 years were 28% and 9%, respectively, with p = .05. Similarly, for low-lying tumors (less than 6 cm from the anorectal junction) the rates were 24% and 9%, respectively, with p = .04. The actuarial rate of distant metastasis was 28% in the low-dose group and 20% in the high-dose group and was not significantly different. Overall actuarial 5-year survival for the total group of patients was 66%. No significant difference in survival was observed between the two groups, despite the higher proportion of unfavorable cancers in the high-dose group. The incidence of complications was 2%, equally distributed between the two groups. High-dose preoperative radiation therapy for rectal cancer results in excellent local control rates. 27 refs., 2 figs., 8 tabs

  7. Methodology of high dose research in medical radiodiagnostic; Metodologia de investigacao de doses elevadas em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana E.; Martins, Cintia P. de S., E-mail: ird@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations.

  8. Preliminary report of a new treatment strategy for advanced pelvic malignancy: surgical resection and radiation therapy using afterloading catheters plus an inflatable displacement prosthesis in the treatment of advanced primary and recurrent rectal cancer

    International Nuclear Information System (INIS)

    Edington, H.D.; Hancock, S.; Coe, F.L.; Sugarbaker, P.H.

    1986-01-01

    An unsolved problem in colon and rectal surgery involves the treatment of locally invasive primary and recurrent rectal cancer. An approach is described that uses intracavitary iridium-192 sources in combination with a pelvic displacement prosthesis to augment external beam radiation doses to sites of residual disease identified at surgery. This approach should permit administration of tumoricidal doses of radiation to positive surgical margins minimizing radiation toxicity to the small bowel. The radiation source and all prosthetic materials are removed at the bedside within 2 weeks of surgery, ensuring accurate radiation dosimetry, minimizing infectious complications, and sparing the patient the need for full high-dose pelvic irradiation

  9. Patients with Pelvic Floor Muscle Spasm Have a Superior Response to Pelvic Floor Physical Therapy at Specialized Centers.

    Science.gov (United States)

    Polackwich, Alan Scott; Li, Jianbo; Shoskes, Daniel A

    2015-10-01

    Chronic prostatitis/chronic pelvic pain syndrome is a common condition that often requires multimodal therapy. Patients with chronic pelvic pain syndrome have a high incidence of pelvic floor spasm, which can be treated with pelvic floor physical therapy. However, this is a specialized skill. We compared outcomes of pelvic floor physical therapy as part of multimodal therapy in patients with chronic pelvic pain syndrome between those treated at our institution and elsewhere. We identified patients from our chronic pelvic pain syndrome registry with pelvic floor spasm who were seen between 2010 and 2014 for more than 1 visit. Patient phenotype was assessed with the UPOINT system and symptom severity was determined by the National Institutes of Health CPSI. A 6-point decrease in CPSI was used to define patient improvement. A total of 82 patients fit the study criteria. Mean age was 41.6 years (range 19 to 75) and median symptom duration was 24 months (range 3 to 240). Mean CPSI was 26.8 (range 10 to 41), the median number of positive UPOINT domains was 3 (range 1 to 6) and 27 patients (32.9%) were treated locally. At followup 9 patients had refused pelvic floor physical therapy, and 24 and 48 had undergone pelvic floor physical therapy elsewhere and at CCF, respectively. The mean change in CPSI was 1.11 ± 4.1 in patients who refused, -3.46 ± 6.7 in those treated elsewhere and -11.3 ± 7.0 in those treated at CCF (p physical therapy at CCF (OR 4.23, p = 0.002) and symptom duration (OR 0.52, p = 0.03) predicted improvement. Pelvic floor physical therapy can be effective for chronic pelvic pain syndrome in patients with pelvic floor spasm. However, the outcome depends on specialty training and experience of therapists. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Routine quality control of high dose rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira

    2001-01-01

    A Quality Assurance program should be installed also for High Dose Rate brachytherapy, in the order to achieve a correct dose administration to the patient and for the safety to those involved directly with the treatment. The work presented here has the following purposes: Analyze the types of equipment tests presented by the official protocols (TG40, TG56 e ARCAL XXX), evaluate the brachytherapy routine tests of protocols from various national and international radiotherapy services and compare the latter with those presented in the official protocols. As a result, we conclude the following: TG56 presents a higher number of tests when compared to the other official protocols and most of the tests presented by the analyzed services are present in TG56. A suggestion for a basic protocol is presented, emphasizing the periodicity and tolerance level of each of the tests. (author)

  11. Development of miniature γ dose rate monitor with high sensitivity

    International Nuclear Information System (INIS)

    Shi Huilu; Tuo Xianguo; Xi Dashun; Tang Rong; Mu Keliang; Yang Jianbo

    2009-01-01

    This paper introduces a miniature γ dose rate monitor with high sensitivity which design based on single chip microcomputer, it can continue monitoring γ dose rate and then choose wire or wireless communications to sent the monitoring data to host according to the actual conditions. It has two kinds of power supply system, AC power supply system and battery which can be chose by concrete circumstances. The design idea and implementation technology of hardware and software and the system structure of the monitor are detailed illustrated in this paper. The experimental results show that measurable range is 0.1 mR/h-200 mR/h, the sensitivity of γ is 90 cps/mR/h, dead time below 200 us, error of stability below ±10%. (authors)

  12. High-dose dosimetry using electron spin resonance (ESR) spectroscopy

    International Nuclear Information System (INIS)

    Kojima, Takuji; Tanaka, Ryuichi

    1992-01-01

    An electron spin resonance (ESR) dosimeter capable of measuring large doses of radiation in radiotherapy and radiation processing is outlined. In particular, an alanine/ESR dosimeter is discussed, focusing on the development of elements, the development of the ESR dosimetric system, the application of alanine/ESR dosimeter, and basic researches. Rod elements for gamma radiation and x radiation and film elements for electron beams are described in detail. The following recent applications of the alanine/ESR dosimeter are introduced: using as a transfer dosimeter, applying to various types of radiation, diagnosing the deterioration of radiological materials and equipments, and applying to ESR imaging. The future subjects to be solved in the alanine/ESR dosimetric system are referred to as follows: (1) improvement of highly accurate elements suitable for the measurement of various types of radiation, (2) establishment of sensitive calibration method of the ESR equipment itself, and (3) calibration and standardization of radiation doses. (K.N.) 65 refs

  13. Use of high irradiation doses for preservation of canned beef

    International Nuclear Information System (INIS)

    Hammad, A.A.I; Salem, F.A.; El-Sahy, K.M.; Rady, A.; Badr, H.H.

    1997-01-01

    The effect of high irradiation doses (11.25,22.5 and 45 KGy) on the bacteriology, organoleptic quality and shelf - life extension of beef meat that are hermetically sealed in metal cans was investigated in comparison with commercial heat sterilization. The unirradiated cans of pre cooked (enzyme inactivated) unirradiated beef were swollen after only one month of storage at ambient temperature (20-30 degree). Application of 11.25 and 22.5 kGy to vacuum packed and enzyme inactivated beef was not enough for sterilization and only delayed swelling of beef cans. Application of 45 KGy irradiation dose prevented swelling of beef vans up to 12 months at ambient temperature and provided meat product, similar to the commercial heat sterilized one, organoleptically acceptable and microbiologically safe. Running title: Radiation sterilization of meat

  14. High and low dose-rate brachytherapy for cervical carcinoma

    International Nuclear Information System (INIS)

    Orton, C.G.

    1998-01-01

    For the brachytherapy component of the r[iation treatment of cervical carcinoma, high dose rate (HDR) is slowly replacing conventional low dose rate (LDR) due primarily to r[iation safety and other physical benefits attributed to the HDR modality. Many r[iation oncologists are reluctant to make this change because of perceived r[iobiological dis[vantages of HDR. However, in clinical practice HDR appears to be as effective as LDR but with a lower risk of late complications, as demonstrated by one randomized clinical trial and two comprehensive literature and practice surveys. The reason for this appears to be that the r[iobiological dis[vantages of HDR are outweighed by the physical [vantages. (orig.)

  15. [Ultrasonography in acute pelvic pain].

    Science.gov (United States)

    Kupesić, Sanja; Aksamija, Alenka; Vucić, Niksa; Tripalo, Ana; Kurjak, Asim

    2002-01-01

    normal intrauterine pregnancy from threatened or spontaneous abortion, ectopic pregnancy and other complications that may occur in patients with positive pregnancy test. Incomplete abortion is visualized as thickened and irregular endometrial echo with certain amount of intracavitary fluid. If applied, color Doppler ultrasound reveals low vascular resistance signals in richly perfused intracavitary area. Transvaginal sonography has high sensitivity and specificity in visualization of uterine and adnexal signs of ectopic pregnancy. Color Doppler examination may aid in detection of the peritrophoblastic flow. Furthermore, it facilitates detection of ectopic living embryo, tubal ring or unspecific adnexal tumor. Corpus luteum cysts and leiomyomas are another cause of pelvic pain during pregnancy, which can be correctly diagnosed by ultrasound. Detection of uterine dehiscence and rupture in patients with history of prior surgical intervention on uterine wall relies exclusively on correct ultrasound diagnosis. In patients with placental abruption sonographer detects hypoechoic complex representing either retroplacental hematoma, subchorionic hematoma or subamniotic hemorrhage. In closing, ultrasound has already become important and easily available tool which can efficiently recognize patients with possibly threatening conditions of different origins.

  16. [Biomechanical modeling of pelvic organ mobility: towards personalized medicine].

    Science.gov (United States)

    Cosson, Michel; Rubod, Chrystèle; Vallet, Alexandra; Witz, Jean-François; Brieu, Mathias

    2011-11-01

    Female pelvic mobility is crucial for urinary, bowel and sexual function and for vaginal delivery. This mobility is ensured by a complex organ suspension system composed of ligaments, fascia and muscles. Impaired pelvic mobility affects one in three women of all ages and can be incapacitating. Surgical management has a high failure rate, largely owing to poor knowledge of the organ support system, including the barely discernible ligamentous system. We propose a 3D digital model of the pelvic cavity based on MRI images and quantitative tools, designed to locate the pelvic ligaments. We thus obtain a coherent anatomical and functional model which can be used to analyze pelvic pathophysiology. This work represents a first step towards creating a tool for localizing and characterizing the source of pelvic imbalance. We examine possible future applications of this model, in terms of personalized therapy and prevention.

  17. Calibration of high-dose radiation facilities (Handbook)

    International Nuclear Information System (INIS)

    Gupta, B.L.; Bhat, R.M.

    1986-01-01

    In India at present several high intensity radiation sources are used. There are 135 teletheraphy machines and 65 high intensity cobalt-60 sources in the form of gamma chambers (2.5 Ci) and PANBIT (50 Ci). Several food irradiation facilities and a medical sterilization plant ISOMED are also in operation. The application of these high intensity sources involve a wide variation of dose from 10 Gy to 100 kGy. Accurate and reproducible radiation dosimetry is essential in the use of these sources. This handbook is especially compiled for calibration of high-dose radiation facilities. The first few chapters discuss such topics as interaction of radiation with matter, radiation chemistry, radiation processing, commonly used high intensity radiation sources and their special features, radiation units and dosimetry principles. In the chapters which follow, chemical dosimeters are discussed in detail. This discussion covers Fricke dosimeter, FBX dosimeter, ceric sulphate dosimeter, free radical dosimetry, coloured indicators for irrdiation verification. A final chapter is devoted to practical hints to be followed in calibration work. (author)

  18. Low dose versus high dose anti-snake venom therapy in the treatment of haematotoxic snake bite in South India.

    Science.gov (United States)

    Joseph, Imanto M; Kuriakose, Cijoy K; Dev, Anand Vimal; Philip, George A

    2017-10-01

    Most of the studies on the appropriate dose of anti-snake venom (ASV) are from tertiary hospitals and the guidelines are unclear. Our observational study compared the outcomes of two prevalent treatment regimes for haematotoxic snake bite in a secondary care hospital in South India. The time to normalisation of whole blood clotting time, mortality and complications were not different between the groups. The average dose of ASV required in the low and high dose groups were 106 mL and 246 mL, respectively. Consequently, patients who received low dose ASV incurred approximately 50% less expense. Urticarial rashes were also significantly fewer in the low dose group.

  19. High Doses Gamma Radiolysis of PVC: Mechanisms of Degradation

    International Nuclear Information System (INIS)

    Colombani, J.

    2006-01-01

    PVC radiolysis leads to the formation of various degradation products: radicals, gas, oxidized products or polyenes. In order to predict the formation of the degradation products with regard to irradiation and ageing parameters, it is important to improve the understanding of the radiolysis mechanisms of PVC. Thus, we used several analytical techniques (Electron Spin Resonance, Fourier Transform Infrared spectroscopy, Nuclear Magnetic Resonance, Size Exclusion Chromatography) to get information on PVC samples irradiated at high doses (up to 4MGy) under different conditions. Gamma irradiation induces the formation of various radicals into PVC. Older studies were generally focused on the effect of low dose and/or low temperature irradiations on PVC. We present here ESR signals of PVC irradiated at high doses and at room temperature. We show that peroxyl radicals are producted by radiolysis under aerobe conditions and that polyenyl radicals are formed under anaerobe conditions. PVC radiolysis induces gas production and especially hydrogen chloride. Production of hydrogen chloride is well known until 1 MGy. We have studied by FTIR, the evolution of the quantity of HCl produced until 4 MGy. We show that higher irradiation dose leads to the lower radiolytic yield of HCl (G(HCl)). Moreover, G(HCl) obtained in aerobe conditions is about fourfold as great as G(HCl) observed in anaerobe radiolysis. Propagation and termination reactions induce degradation products: polyene sequences and crosslinking reactions are observed under anaerobe conditions; oxidized products with addition of chain scissions are formed under aerobe conditions. Although the literature about PVC radiolysis is rich, the main reacting pathways are not well established. Moreover the high doses studies are almost non-existent. We show by FTIR that aerobe radiolysis induces formation of ketons and acids. NMR experiments confirme these results but also focuse on small acids formed (with 2, 3 or 4 carbons). The

  20. High-dose radioiodine therapy of Graves disease

    International Nuclear Information System (INIS)

    Solodky, V.; Fomin, D.; Pestritskaya, E.

    2015-01-01

    Full text of publication follows. Objectives: to estimate the effectiveness and safety of the disease treatment under different modes of applying RIT. Materials and methods: 67 patients with the thyrotoxicosis condition associated with Graves disease were researched. The patients were divided into 2 groups: a control group with 25 people (18 women and 7 men), who underwent a low-dose therapy of 150-500 MBq; and a main group of 42 people (32 women and 10 men), who underwent a high-dose therapy of 550 and 800 MBq. The volume of thyroid prior to the treatment made up 23.8 ± 20 ml in the main group and 30.2 ± 23 ml in the control one. The average age in the high-dose group was 44.6 ±23 years old and in the low-dose -47.2 ± 24 years old. In terms of the hormone level before the RIT, 52% of the main group patients experienced euthyroidism, while 48% - thyrotoxicosis. The corresponding indices in the control group were 42% and 58% respectively. The cessation of the thyreostatic therapy came on 5. to 21. day prior to the treatment, with the average of 14 ±7 days in both groups. The diagnosis of the disease was based on ultrasonography, planar scintigraphy, the hormone level and antibody titer. The performance was assessed through the attainment of hypo-thyrosis and the transition to a substitutive hormonal therapy with L-thyroxine in 6 months or more. The attainment of euthyroidism was seen as a partial effect due to a possibility of relapse. Results: in 6 months a positive result in the form of hypo-thyrosis was achieved for 39 patients in the main group, which accounted for 93%, and 3 patients (7%) experienced euthyroidism. No symptomatic thyrotoxicosis relapses were revealed. In the control group, hypo-thyrosis was achieved by 18 patients, which accounted for 72%; euthyroidism came up to 12%; 4 patients needed a refresher course of RIT, which made up 16% of the group. 93% of the main group patients tolerated the treatment favourably. 3 patients complained of the

  1. Cooperative binding mitigates the high-dose hook effect.

    Science.gov (United States)

    Roy, Ranjita Dutta; Rosenmund, Christian; Stefan, Melanie I

    2017-08-14

    The high-dose hook effect (also called prozone effect) refers to the observation that if a multivalent protein acts as a linker between two parts of a protein complex, then increasing the amount of linker protein in the mixture does not always increase the amount of fully formed complex. On the contrary, at a high enough concentration range the amount of fully formed complex actually decreases. It has been observed that allosterically regulated proteins seem less susceptible to this effect. The aim of this study was two-fold: First, to investigate the mathematical basis of how allostery mitigates the prozone effect. And second, to explore the consequences of allostery and the high-dose hook effect using the example of calmodulin, a calcium-sensing protein that regulates the switch between long-term potentiation and long-term depression in neurons. We use a combinatorial model of a "perfect linker protein" (with infinite binding affinity) to mathematically describe the hook effect and its behaviour under allosteric conditions. We show that allosteric regulation does indeed mitigate the high-dose hook effect. We then turn to calmodulin as a real-life example of an allosteric protein. Using kinetic simulations, we show that calmodulin is indeed subject to a hook effect. We also show that this effect is stronger in the presence of the allosteric activator Ca 2+ /calmodulin-dependent kinase II (CaMKII), because it reduces the overall cooperativity of the calcium-calmodulin system. It follows that, surprisingly, there are conditions where increased amounts of allosteric activator actually decrease the activity of a protein. We show that cooperative binding can indeed act as a protective mechanism against the hook effect. This will have implications in vivo where the extent of cooperativity of a protein can be modulated, for instance, by allosteric activators or inhibitors. This can result in counterintuitive effects of decreased activity with increased concentrations of

  2. High-dose MeV electron irradiation of Si-SiO2 structures implanted with high doses Si+

    Science.gov (United States)

    Kaschieva, S.; Angelov, Ch; Dmitriev, S. N.

    2018-03-01

    The influence was studied of 22-MeV electron irradiation on Si-SiO2 structures implanted with high-fluence Si+ ions. Our earlier works demonstrated that Si redistribution is observed in Si+-ion-implanted Si-SiO2 structures (after MeV electron irradiation) only in the case when ion implantation is carried out with a higher fluence (1016 cm-2). We focused our attention on the interaction of high-dose MeV electron irradiation (6.0×1016 cm-2) with n-Si-SiO2 structures implanted with Si+ ions (fluence 5.4×1016 cm-2 of the same order magnitude). The redistribution of both oxygen and silicon atoms in the implanted Si-SiO2 samples after MeV electron irradiation was studied by Rutherford back-scattering (RBS) spectroscopy in combination with a channeling technique (RBS/C). Our results demonstrated that the redistribution of oxygen and silicon atoms in the implanted samples reaches saturation after these high doses of MeV electron irradiation. The transformation of amorphous SiO2 surface into crystalline Si nanostructures (after MeV electron irradiation) was evidenced by atomic force microscopy (AFM). Silicon nanocrystals are formed on the SiO2 surface after MeV electron irradiation. The shape and number of the Si nanocrystals on the SiO2 surface depend on the MeV electron irradiation, while their size increases with the dose. The mean Si nanocrystals height is 16-20 nm after irradiation with MeV electrons at the dose of 6.0×1016 cm-2.

  3. The status of low dose rate and future of high dose rate Cf-252 brachytherapy

    International Nuclear Information System (INIS)

    Rivard, M.J.; Wierzbicki, J.G.; Van den Heuvel, F.; Chuba, P.J.; Fontanesi, J.

    1997-12-01

    This work describes the current status of the US low dose rate (LDR) Cf-252 brachytherapy program. The efforts undertaken towards development of a high dose rate (HDR) remotely after loaded Cf-252 source, which can accommodate 1 mg or greater Cf-252, are also described. This HDR effort is a collaboration between Oak Ridge National Laboratory (ORNL), commercial remote after loader manufactures, the Gershenson Radiation Oncology Center (ROC), and Wayne State University. To achieve this goal, several advances in isotope chemistry and source preparation at ORNL must be achieved to yield a specific material source loading of greater than or equal 1 mg Cf-252 per mm3. Development work with both radioactive and non-radioactive stand-ins for Cf-252 have indicated the feasibility of fabricating such sources. As a result, the decreased catheter diameter and computer controlled source placement will permit additional sites (e.g. brain, breast, prostate, lung, parotid, etc.) to be treated effectively with Cf-252 sources. Additional work at the Radiochemical Engineering and Development Center (REDC) remains in source fabrication, after loader modification, and safe design. The current LDR Cf-252 Treatment Suite at the ROC is shielded and licensed to hold up to 1 mg of Cf-252. This was designed to maintain cumulative personnel exposure, both external to the room and in direct isotope handling, at less than 20 microSv/hr. However, cumulative exposure may be greatly decreased if a Cf-252 HDR unit is employed which would eliminate direct isotope handling and decrease treatment times from tilde 3 hours to an expected range of 3 to 15 minutes. Such a Cf-252 HDR source will also demonstrate improved dose distributions over current LDR treatments due to the ability to step the point-like source throughout the target volume and weight the dwell time accordingly

  4. Diagnosis of cerebral metastases by means of standard doses of Gadobutrol versus a high-dose protocol. Intraindividual evaluation of a phase-II high-dose study

    International Nuclear Information System (INIS)

    Vogl, T.J.; Friebe, C.E.; Balzer, T.; Mack, M.G.; Steiner, S.; Schedel, H.; Pegios, W.; Lanksch, W.; Banzer, D.; Felix, R.

    1995-01-01

    In a clinical phase-II study 20 patients who had been diagnosed as having brain metastases with CT or MRT were studied prospectively with Gadobutrol, a new nonionic, low osmolality contrast agent. Each patient received an initial injection of 0.1 mmol/kg body weight and an additional dose of 0.2 mmol/kg Gadobutrol 10 min later. Spinecho images were obtained before and after the two applications of Gadobutrol. Dynamic scanning (Turbo-FLASH) was performed for 3 min after each injection of the contrast agent. Both quantitative and qualitative data were intraindividually evaluated. The primary tumor was a bronchial carcinoma in 11 cases; in 9 other cases there were different primary tumors. Forty-eight hours after the use of Gadobutrol there were no adverse signs in the clinical examination, vital signs or blood and urine chemistry. Statistical analysis (Friedman test and Wilcoxon test) of the C/N ratios between tumor and white matter, percentage enhancement, and visual assessment rating revealed statistically significant superiority of high-dose Gadobutrol injection in comparison to the standard dose. The percentage enhancement increased on average from 104% after 0.1 mmol/kg to 162% after 0.3 mmol/kg Gadobutrol. Qualitative delineation and contrast of the lesions increased significantly. The use of high-dose Gadobutrol improved the detection of 36 additional lesions in 6 patients. (orig./VHE) [de

  5. High dose tetrabromobisphenol A impairs hippocampal neurogenesis and memory retention.

    Science.gov (United States)

    Kim, Ah Hyun; Chun, Hye Jeong; Lee, Seulah; Kim, Hyung Sik; Lee, Jaewon

    2017-08-01

    Tetrabromobisphenol A (TBBPA) is a brominated flame retardant that is commonly used in commercial and household products, such as, computers, televisions, mobile phones, and electronic boards. TBBPA can accumulate in human body fluids, and it has been reported that TBBPA possesses endocrine disruptive activity. However, the neurotoxic effect of TBBPA on hippocampal neurogenesis has not yet been investigated. Accordingly, the present study was undertaken to evaluate the effect of TBBPA on adult hippocampal neurogenesis and cognitive function. Male C57BL/6 mice were orally administrated vehicle or TBBPA (20 mg/kg, 100 mg/kg, or 500 mg/kg daily) for two weeks. TBBPA was observed to significantly and dose-dependently reduce the survival of newly generated cells in the hippocampus but not to affect the proliferation of newly generated cells. Numbers of hippocampal BrdU and NeuN positive cells were dose-dependently reduced by TBBPA, indicating impaired neurogenesis in the hippocampus. Interestingly, glial activation without neuronal death was observed in hippocampi exposed to TBBPA. Furthermore, memory retention was found to be adversely affected by TBBPA exposure by a mechanism involving suppression of the BDNF-CREB signaling pathway. The study suggests high dose TBBPA disrupts hippocampal neurogenesis and induces associated memory deficits. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Stock selection of high-dose-irradiation-resistant materials for filter press under high-dose irradiation operation

    International Nuclear Information System (INIS)

    Ishiyama, Shintaro; Minami, Mamoru; Hara, Kouji; Yamashita, Manabu

    2015-01-01

    In a volume reduction process for the decontamination of contained soil, the performance degradation of a filter press is expected owing to material deterioration under high-dose irradiation. Eleven-stock selection of candidate materials including polymers, fibers and rubbers for the filter press was conducted to achieve a high performance of volume reduction of contaminated soil and the following results were derived. Crude rubber and nylon were selected as prime candidates for packing, diaphragm and filter plate materials. Polyethylene was also selected as a prime candidate for the filter cloth material. (author)

  7. Physiological and immunological changes following exposure to low versus high-dose ionizing irradiation; comparative analysis with dose rate and cumulative dose

    International Nuclear Information System (INIS)

    Heesun, Kim; Heewon, Jang; Soungyeon, Song; Shinhye, Oh; Cukcheul, Shin; Meeseon, Jeong; Chasoon, Kim; Kwnaghee, Yang; Seonyoung, Nam; Jiyoung, Kim; Youngwoo, Jin; Changyoung, Cha

    2008-01-01

    Full text: While high-dose of ionizing radiation is generally harmful and causes damage to living organisms some reports suggest low-dose of radiation may not be as damaging as previously thought. Despite increasing evidence regarding the protective effect of low-dose radiation, no studies have directly compared the exact dose-response pattern by high- and low-dose of radiation exposed at high-and low-dose rate. This study aims to explore the cellular and molecular changes in mice exposed to low- and high-dose of radiation exposed at low- and high-dose rate. When C57BL/6 mice (Female, 6 weeks) were exposed at high-dose rate, 0.8 Gy/min, no significant change on the level of WBC, RBC, or platelets was observed up to total dose of 0.5 Gy. However, 2 Gy of radiation caused dramatic reduction in the level of white blood cells (WBC) and platelets. This reduction was accompanied by increased DNA damage in hematopoietic environments. The reduction of WBC was mainly due to the reduction in the number of CD4+ T cells and CD19+ B cells. CD8+ T cells and NK cells appeared to be relatively resistant to high-dose of radiation. This change was also accompanied by the reduction of T- and B- progenitor cells in the bone marrow. In contrast, no significant changes of the number of CD4+ T, CD8+ T, NK, and B cells were observed in the spleen of mice exposed at low-dose-rate (0.7 m Gy/h or 3.95 mGy/h) for up to 2 Gy, suggesting that low-dose radiation does not alter cellular distribution in the spleen. Nevertheless, mice exposed to low-dose radiation exhibited elevation of VEGF, MCP-1, IL-4, Leptin, IL-3, and Tpo in the peripheral blood and slight increases in MIP-2, RANTES, and IL-2 in the spleen. This suggests that chronic γ-radiation can stimulate immune function without causing damage to the immune components of the body. Taken together, these data indicate hormesis of low-dose radiation, which could be attributed to the stimulation of immune function. Dose rate rather than total

  8. Conventional-Dose versus High-Dose Chemotherapy for Relapsed Germ Cell Tumors

    Directory of Open Access Journals (Sweden)

    Deaglan J. McHugh

    2018-01-01

    Full Text Available The majority of metastatic germ cell tumors (GCTs are cured with cisplatin-based chemotherapy, but 20–30% of patients will relapse after first-line chemotherapy and require additional salvage strategies. The two major salvage approaches in this scenario are high-dose chemotherapy (HDCT with autologous stem cell transplant (ASCT or conventional-dose chemotherapy (CDCT. Both CDCT and HDCT have curative potential in the management of relapsed/refractory GCT. However, due to a lack of conclusive randomized trials, it remains unknown whether sequential HDCT or CDCT represents the optimal initial salvage approach, with practice varying between tertiary institutions. This represents the most pressing question remaining for defining GCT treatment standards and optimizing outcomes. The authors review prognostic factors in the initial salvage setting as well as the major studies assessing the efficacy of CDCT, HDCT, or both, describing the strengths and weaknesses that formed the rationale behind the ongoing international phase III “TIGER” trial.

  9. Prehospital high-dose sublingual nitroglycerin rarely causes hypotension.

    Science.gov (United States)

    Clemency, Brian M; Thompson, Jeffrey J; Tundo, Gina N; Lindstrom, Heather A

    2013-10-01

    High-dose intravenous nitroglycerin is a common in-hospital treatment for respiratory distress due to congestive heart failure (CHF) with hypertension. Intravenous (IV) nitroglycerin administration is impractical in the prehospital setting. In 2011, a new regional Emergency Medical Services (EMS) protocol was introduced allowing advanced providers to treat CHF with high-dose oral nitroglycerin. The protocol calls for patients to be treated with two sublingual tabs (0.8 mg) when systolic blood pressure (SBP) was >160 mm Hg, or three sublingual tabs (1.2 mg) when SBP was >200 mm Hg, every five minutes as needed. Hypothesis/Problem To assess the protocol's safety, the incidence of hypotension following prehospital administration of multiple simultaneous nitroglycerin (MSN) tabs by EMS providers was studied. This study was a retrospective cohort study of patients from a single commercial EMS agency over a 6-month period. Records from patients with at least one administration of MSN were reviewed. For each administration, the first documented vital signs pre- and post-administration were compared. Administrations were excluded if pre- or post-administration vital signs were missing. One hundred case-patients had at least one MSN administration by an advanced provider during the study period. Twenty-five case-patients were excluded due to incomplete vital signs. Seventy-five case-patients with 95 individual MSN administrations were included for analysis. There were 65 administrations of two tabs, 29 administrations of three tabs, and one administration of four tabs. The mean change in SBP following MSN was -14.7 mm Hg (SD = 30.7; range, +59 to -132). Three administrations had documented systolic hypotension in the post-administration vital signs (97/71, 78/50 and 66/47). All three patients were over 65 years old, were administered two tabs, had documented improved respiratory status, and had repeat SBP of at least 100. The incidence of hypotension following MSN

  10. High-dose irradiated food: Current progress, applications, and prospects

    Science.gov (United States)

    Feliciano, Chitho P.

    2018-03-01

    Food irradiation as an established and mature technology has gained more attention in the food industry for ensuring food safety and quality. Primarily used for phytosanitary applications, its use has been expanded for developing various food products for varied purposes (e.g. ready-to-eat & ready-to-cook foods, hospital diets, etc.). This paper summarized and analyzed the recent progress and application of high-dose irradiation and discussed its prospects in the field of food product development, its safety and quality.

  11. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  12. Identification of dose-reduction techniques for BWR and PWR repetitive high-dose jobs

    International Nuclear Information System (INIS)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    As a result of concern about the apparent increase in collective radiation dose to workers at nuclear power plants, this project will provide information to industry in preplanning for radiation protection during maintenance operations. This study identifies Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) repetitive jobs, and respective collective dose trends and dose reduction techniques. 3 references, 2 tables

  13. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  14. Pelvic floor muscle function in women with pelvic floor dysfunction

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Dehlendorff, Christian

    2014-01-01

    The objectives of this study were to investigate the level of pelvic floor muscle (PFM) function in women with pelvic floor dysfunction (PFD) referred by gynaecologists and urologists for in-hospital pelvic floor muscle training (PFMT), and to identity associated factors for a low level of PFM...

  15. Physics and quality assurance for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Anderson, Lowell L.

    1995-01-01

    Purpose: To review the physical aspects of high dose rate (HDR) brachytherapy, including commissioning and quality assurance, source calibration and dose distribution measurements, and treatment planning methods. Following the introduction of afterloading in brachytherapy, development efforts to make it 'remote' culminated in 1964 with the near-simultaneous appearance of remote afterloaders in five major medical centers. Four of these machines were 'high dose rate', three employing 60Co and one (the GammaMed) using a single, cable-mounted 192Ir source. Stepping-motor source control was added to the GammaMed in 1974, making it the precursor of modern remote afterloaders, which are now suitable for interstitial as well as intracavitary brachytherapy by virtue of small source-diameter and indexer-accessed multiple channels. Because the 192Ir sources currently used in HDR remote afterloaders are supplied at a nominal air-kerma strength of 11.4 cGy cm2 s-1 (10 Ci), are not collimated in clinical use, and emit a significant fraction (15%) of photons at energies greater than 600 keV, shielding and facility design must be undertaken as carefully and thoroughly as for external beam installations. Licensing requirements of regulatory agencies must be met with respect both to maximum permissible dose limits and to the existence and functionality of safety devices (door interlocks, radiation monitors, etc.). Commissioning and quality assurance procedures that must be documented for HDR remote afterloading relate to (1) machine, applicator, guide-tube, and facility functionality checks, (2) source calibration, (3) emergency response readiness, (4) planning software evaluation, and (5) independent checks of clinical dose calculations. Source calibration checks must be performed locally, either by in-air measurement of air kerma strength or with a well ionization chamber calibrated (by an accredited standards laboratory) against an in-air measurement of air kerma strength for the

  16. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  17. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  18. Clinical application of a OneDose MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast.

    Science.gov (United States)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.

  19. The impact of antiplatelet therapy on pelvic fracture outcomes

    Directory of Open Access Journals (Sweden)

    Christy Jonathan

    2011-01-01

    Full Text Available Introduction : Despite increasing use of antiplatelet agents (APA, little is known regarding the effect of these agents on the orthopedic trauma patient. This study reviews clinical outcomes of patients with pelvic fractures (Pfx who were using pre-injury APA. Specifically, we focused on the influence of APA on postinjury bleeding, transfusions, and outcomes after Pfx. Methods : Patients with Pfx admitted during a 37-month period beginning January 2006 were divided into APA and non-APA groups. Pelvic injuries were graded using pelvic fracture severity score (PFSS-a combination of Young-Burgess (pelvic ring, Letournel-Judet (acetabular, and Denis (sacral fracture classifications. Other clinical data included demographics, co-morbid conditions, medications, injury severity score (ISS, associated injuries, morbidity/mortality, hemoglobin trends, blood product use, imaging studies, procedures, and resource utilization. Multivariate analyses for predictors of early/late transfusions, pelvic surgery, and mortality were performed. Results : A total of 109 patients >45 years with Pfx were identified, with 37 using preinjury APA (29 on aspirin [ASA], 8 on clopidogrel, 5 on high-dose/scheduled non-steroidal anti-inflammatory agents [NSAID], and 8 using >1 APAs. Patients in the APA groups were older than patients in the non-APA group (70 vs. 63 years, P < 0.01. The two groups were similar in gender distribution, PFSS and ISS. Patients in the APA group had more comorbidities, lower hemoglobin levels at 24 h, and received more packed red blood cell (PRBC transfusions during the first 24 h of hospitalization (all, P < 0.05. There were no differences in platelet or late (>24 h PRBC transfusions, blood loss/transfusions during pelvic surgery, lengths of stay, post-ED/discharge disposition, or mortality. In multivariate analysis, predictors of early PRBC transfusion included higher ISS/PFSS, pre-injury ASA use, and lower admission hemoglobin (all, P < 0

  20. Physical activity and the pelvic floor.

    Science.gov (United States)

    Nygaard, Ingrid E; Shaw, Janet M

    2016-02-01

    Pelvic floor disorders are common, with 1 in 4 US women reporting moderate to severe symptoms of urinary incontinence, pelvic organ prolapse, or fecal incontinence. Given the high societal burden of these disorders, identifying potentially modifiable risk factors is crucial. Physical activity is one such potentially modifiable risk factor; the large number of girls and women participating in sport and strenuous training regimens increases the need to understand associated risks and benefits of these exposures. The aim of this review was to summarize studies reporting the association between physical activity and pelvic floor disorders. Most studies are cross-sectional and most include small numbers of participants. The primary findings of this review include that urinary incontinence during exercise is common and is more prevalent in women during high-impact sports. Mild to moderate physical activity, such as brisk walking, decreases both the odds of having and the risk of developing urinary incontinence. In older women, mild to moderate activity also decreases the odds of having fecal incontinence; however, young women participating in high-intensity activity are more likely to report anal incontinence than less active women. Scant data suggest that in middle-aged women, lifetime physical activity increases the odds of stress urinary incontinence slightly and does not increase the odds of pelvic organ prolapse. Women undergoing surgery for pelvic organ prolapse are more likely to report a history of heavy work than controls; however, women recruited from the community with pelvic organ prolapse on examination report similar lifetime levels of strenuous activity as women without this examination finding. Data are insufficient to determine whether strenuous activity while young predisposes to pelvic floor disorders later in life. The existing literature suggests that most physical activity does not harm the pelvic floor and does provide numerous health benefits for

  1. Radiation safety program in a high dose rate brachytherapy facility

    International Nuclear Information System (INIS)

    Rodriguez, L.V.; Hermoso, T.M.; Solis, R.C.

    2001-01-01

    The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. Several accidents, however, have been reported involving high dose-rate brachytherapy system. These events, together with the desire to address the concerns of radiation workers, and the anticipated adoption of the International Basic Safety Standards for Protection Against Ionizing Radiation (IAEA, 1996), led to the development of the radiation safety program at the Department of Radiotherapy, Jose R. Reyes Memorial Medical Center and at the Division of Radiation Oncology, St. Luke's Medical Center. The radiation safety program covers five major aspects: quality control/quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. Measures for evaluation of effectiveness of the program include decreased unnecessary exposures of patients and staff, improved accuracy in treatment delivery and increased department efficiency due to the development of staff vigilance and decreased anxiety. The success in the implementation required the participation and cooperation of all the personnel involved in the procedures and strong management support. This paper will discuss the radiation safety program for a high dose rate brachytherapy facility developed at these two institutes which may serve as a guideline for other hospitals intending to install a similar facility. (author)

  2. Dosimetric properties of commercial glasses and sand for high doses

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines

    2004-01-01

    Commercial glasses (transparent and colored) produced by Cebrace, Brazil, Sao Paulo, and sand samples of different Brazilian beaches were studied, due to their low cost and easy handling, to verify the possibility of their use in high dose dosimetry. The main dosimetric characteristics were determined using a densitometer, a spectrophotometer, a thermoluminescent (TL) reader and an electronic paramagnetic resonance system. The gamma irradiations were carried out using a Gamma-Cell 220 and a panoramic source ( 60 Co) of IPEN. An optical absorption band was observed at 420 nm in the glass samples. The TL glow curves presented peaks at 205 deg C, 135 deg C, 150 deg C and 145 deg C for the transparent, bronze, brown and green glass samples, respectively. All EPR spectra of the glasses showed Fe 3+ characteristic signals at g = 4.27 and 2.01. The gamma irradiated sand samples presented two peaks at 110 deg C and 170 deg C and an EPR signal at g= 1.999. However, these materials present a pronounced thermal fading at room temperature after irradiation. With the objective to minimize this thermal fading, both glass and sand samples were submitted to different pre- and post-irradiation thermal treatments. The glass and sand samples showed the possibility of utilization for high dose dosimetry and as Yes/No irradiation detectors. (author)

  3. Audits in high dose rate brachytherapy in Brazil

    International Nuclear Information System (INIS)

    Marechal, M.H.; Rosa, L.A.; Velasco, A.; Paiva, E. de; Goncalves, M.; Castelo, L.C.

    2002-01-01

    The lack of well established dosimetry protocols for HDR sources is a point of great concern regarding the uniformity of procedures within a particular country. The main objective of this paper is to report the results of an implementation of the audit program in dosimetry of high dose rate brachytherapy sources used by the radiation therapy centers in Brazil. In Brazil, among 169 radiotherapy centers, 35 have HDR brachytherapy systems. This program started in August 2001 and until now eight radiotherapy services were audited. The audit program consists of the visit in loco to each center and the evaluation of the intensity of the source with a well type chamber specially design for HDR 192 Ir sources. The measurements was carried out with a HDR1000PLUS Brachytherapy Well Type Chamber and a MAX 4000 Electrometer, both manufactured by Standard Imaging Inc. The chamber was calibrated in air kerma strength by the Accredited Dosimetry Calibration Laboratory, Department of Medical Physics, University of Wisconsin in the USA. The same chamber was calibrated in Brazil using a 192 lr high dose rate source whose intensity was determined by 60 Co gamma rays and 250 kV x rays interpolation methodology. The Nk of 60 Co and 250 kV x rays were provided by the Brazilian National Standard Laboratory for Ionizing Radiation (LMNRI)

  4. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-01-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  5. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-10-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  6. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.

    Science.gov (United States)

    Schwarz, Timo Julian; Weber, Markus; Dornia, Christian; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Craiovan, Benjamin

    2017-09-01

    Purpose  Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method  In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results  The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion  Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points   · Pelvic tilt and rotation influence cup

  7. Retroperitoneal and pelvic fibromatosis

    International Nuclear Information System (INIS)

    Lopez de Lacalle, J. M.; Garmendia, G.; Laso, C.; Galardi, A.

    1998-01-01

    We present a case of retroperitoneal and pelvic fibromatosis in a 17-year-old boy who came to the emergency room with sudden onset acute abdominal pain. The initial radiological examination (plain X-ray and ultrasound) disclosed only minimal right hydronephrosis. Subsequent computed tomography revealed the presence of a solid retroperitoneal and pelvic mass involving right ureter and secondary right hydronephrosis. We stress its presentation in the form of acute abdominal pain with initial radiological signs suggestive of a primarily urological disorder. (Author) 8 refs

  8. Pelvic actinomycosis presenting with a large abscess and bowel stenosis with marked response to conservative treatment: a case report

    Directory of Open Access Journals (Sweden)

    Nozawa Hiroaki

    2007-11-01

    Full Text Available Abstract Pelvic actinomycosis is a rare disease that can result in abscess formation, bowel obstruction, and other serious complications. Moreover, the correct diagnosis can seldom be established before radical surgery because the disease often mimics pelvic neoplasms. It has been recently recognized that pelvic actinomycosis is associated with long-term use of an intrauterine contraceptive device. We report a woman with a long-standing intrauterine contraceptive device who visited our hospital complaining of symptoms mimicking large bowel ileus with a subacute course. X-ray fluorography and sigmoidoscopy showed marked stenosis in the sigmoid colon but rejected the possibility of colon cancers. Abdomino-pelvic CT and MRI revealed a huge abscess lying over the urinary bladder and anterior to the uterus. Furthermore, a cervical Papanicolaou smear disclosed Actinomyces species. We removed the intrauterine device from the patient. Subsequent high-dose ampicillin administration led to dramatic shrinkage of the abscess and improved the management of the bowel movement quickly. This is a successful case of symptomatic pelvic actinomycosis that was correctly diagnosed and treated without unnecessary surgical intervention.

  9. Complications Following Balloon-Occluded Arterial Infusion Chemotherapy for Pelvic Malignancies

    International Nuclear Information System (INIS)

    Sugimoto, Koji; Hirota, Shozo; Imanaka, Kazufumi; Kawabe, Tetsuya; Nakayama, Yoshiharu; Takeuchi, Yasuhito

    1999-01-01

    Purpose: To evaluate the incidence and causes of complications associated with balloon-occluded arterial infusion chemotherapy (BOAI) for pelvic malignancies. Methods: In 34 courses of BOAI in 22 patients with pelvic malignancies, we analyzed the incidence of complications as well as the effect of the dose of the anticancer drugs, the infusion site, and the number of BOAI administrations on these complications. Complications were divided into two categories: cystitis-like symptoms and neurological complications such as pain, numbness, and paresthesia of the lower extremities and the hip. Results: Eleven patients (50%) suffered from complications, seven (31.8%) from neurological complications and four (18.2%) from cystitis-like symptoms. The complications appeared in 14 courses (42.4%) of BOAI, neurological complications in 10 (30.3%) and cystitis-like symptoms in four (12.1%). A high dose of anti-cancer drugs and infusion from the anterior division tended to induce neurological complications more frequently; however, the cystitis-like symptoms were not related to any factors. Conclusion: Our results indicate that a smaller dose of anti-cancer drugs should be infused from the bilateral internal iliac arteries for safer pelvic BOAI

  10. High dose rate versus medium dose rate intraluminal brachytherapy in inoperable esophageal carcinoma

    International Nuclear Information System (INIS)

    Langendijk, J.; Jager, J.; Jong, J. de; Rijken, J.; Pannebakker, M.

    1996-01-01

    Introduction: The purpose of this study was to compare the results of medium dose rate (MDR) intraluminal brachytherapy (ILBT) and high dose rate (HDR) ILBT in patients with inoperable esophageal carcinoma, with regard to dysphagia, complication rate and survival. Material and methods: Included were 114 patients with inoperable esophageal cancer who were treated with a single session of ILBT. In all cases a single dose of 15 Gy was administered, calculated at a 1 cm radius. Forty-eight patients were treated with MDR ( 137 Cs)ILBT. In June 1990 MDR was replaced by HDR and from then 66 patients were treated with HDR ( 192 Ir). Dysphagia was prospectively scored using a 5-point scale at 6 weeks, 3, 6, 9 and 12 months. Results: No significant differences were noted between the two groups with regard to pretreatment variables. In patients treated with MDR-ILBT improvement of swallowing ability was noted in 30 out of 42 evaluable patients (71%), no change in 9 (21%) and progression of dysphagia in 3 patients (8%), as compared to 34 out of 59 evaluable patients (58%), 16 (27%) and 6 (15%) resp. in de HDR-ILBT group. In the latter category, progression of dysphagia was caused by fistulae in 2 patients. The differences were not significant (ns). Additional treatment in case of recurrent or persistent dysphagia was needed in 50% of the cases in the MDR-ILBT group as compared to 41% in the HDR-ILBT group (ns). The median survival of the MDR-ILBT group was 3.9 months as compared to 4.3 months in the HDR-ILBT group (ns). In 2 patients (4%) treated with MDR-ILBT bronchio-oesphageal fistulae developed at 6 weeks and 2 months. In the HDR-ILBT group fistulae were noted in 7 cases (11%) at 2 weeks, 4 weeks, 2, 3, 3, 4 and 9 months (ns). In all of these cases persistent of recurrent tumour was present. Conclusions: No significant differences were noted with regard to palliation of dysphagia, survival and complication rate between MDR-ILBT and HDR-ILBT in the management of esophageal

  11. Lack of benefit for the addition of androgen deprivation therapy to dose-escalated radiotherapy in the treatment of intermediate- and high-risk prostate cancer.

    LENUS (Irish Health Repository)

    Krauss, Daniel

    2012-02-01

    PURPOSE: Assessment of androgen deprivation therapy (ADT) benefits for prostate cancer treated with dose-escalated radiotherapy (RT). METHODS AND MATERIALS: From 1991 to 2004, 1,044 patients with intermediate- (n = 782) or high-risk (n = 262) prostate cancer were treated with dose-escalated RT at William Beaumont Hospital. Patients received external-beam RT (EBRT) alone, brachytherapy (high or low dose rate), or high dose rate brachytherapy plus pelvic EBRT. Intermediate-risk patients had Gleason score 7, prostate-specific antigen (PSA) 10.0-19.9 ng\\/mL, or Stage T2b-T2c. High-risk patients had Gleason score 8-10, PSA >\\/=20, or Stage T3. Patients were additionally divided specifically by Gleason score, presence of palpable disease, and PSA level to further define subgroups benefitting from ADT. RESULTS: Median follow-up was 5 years; 420 patients received ADT + dose-escalated RT, and 624 received dose-escalated RT alone. For all patients, no advantages in any clinical endpoints at 8 years were associated with ADT administration. No differences in any endpoints were associated with ADT administration based on intermediate- vs. high-risk group or RT modality when analyzed separately. Patients with palpable disease plus Gleason >\\/=8 demonstrated improved clinical failure rates and a trend toward improved survival with ADT. Intermediate-risk patients treated with brachytherapy alone had improved biochemical control when ADT was given. CONCLUSION: Benefits of ADT in the setting of dose-escalated RT remain poorly defined. This question must continue to be addressed in prospective study.

  12. High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

    International Nuclear Information System (INIS)

    Ghadjar, Pirus; Bojaxhiu, Beat; Simcock, Mathew; Terribilini, Dario; Isaak, Bernhard; Gut, Philipp; Wolfensberger, Patrick; Brömme, Jens O.; Geretschläger, Andreas; Behrensmeier, Frank; Pica, Alessia; Aebersold, Daniel M.

    2012-01-01

    Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3–23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

  13. High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ghadjar, Pirus, E-mail: pirus.ghadjar@insel.ch [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Bojaxhiu, Beat [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Simcock, Mathew [Swiss Group for Clinical Cancer Research Coordinating Center, Bern (Switzerland); Terribilini, Dario; Isaak, Bernhard [Division of Medical Radiation Physics, Inselspital, Bern University Hospital, and University of Bern, Bern (Switzerland); Gut, Philipp; Wolfensberger, Patrick; Broemme, Jens O.; Geretschlaeger, Andreas; Behrensmeier, Frank; Pica, Alessia; Aebersold, Daniel M. [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland)

    2012-07-15

    Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3-23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

  14. Biological dose estimation and comet analysis of the victims in a high dose 60Co radiation accident

    International Nuclear Information System (INIS)

    Chen Ying; Liu Xiulin; Luo Yisheng; Li You; Yao Bo

    2007-01-01

    Objective: To explore the methods of chromosome preparation in human peripheral blood and bone marrow after very high dose exposure and fit the dose-response curve of dicentrics and tings in the range of high doses over 6 Gy for estimating biological dose and detecting DNA damage in the victims of '10.21' accident. Methods: The samples of peripheral blood and bone marrow in 2 victims were collected to prepare chromosome mataphases and dicentrics (multicentrics) + rings were counted. The dose-response curve and equation of human blood irradiated between 6-22 Gy in vitro were established and applied to assess biological dose of 2 victims. In addition, their DNA damages were tested by alkaline single cell gel electrophoresis. Results: The dicentric + ring numbers of 4.47 per cell in victims B's peripheral blood lymphocytes and 9.15 per cell in victim A's bone marrow who had no mitosis in peripheral blood cell. The whole body average doses of victims B and A estimated by 6-22 Gy equation arrived at 9.4 Gy and 19.5 Gy, respectively. The serious DNA damages were expressed by small head and large tail comet figures. Conclusions: The biological doses of 2 victims estimated by 6-22 Gy dose-response curve have reached the levels of extreme grave bone marrow and intestinal ARS, respectively. (authors)

  15. An Atraumatic Symphysiolysis with a Unilateral Injured Sacroiliac Joint in a Patient with Cushing’s Disease: A Loss of Pelvic Stability Related to Ligamentous Insufficiency?

    Directory of Open Access Journals (Sweden)

    Andreas Höch

    2016-01-01

    Full Text Available Glucocorticoids are well known for altering bone structure and elevating fracture risk. Nevertheless, there are very few reports on pelvic ring fractures, compared to other bones, especially with a predominantly ligamentous insufficiency, resulting in a rotationally unstable pelvic girdle. We report a 39-year-old premenopausal woman suffering from an atraumatic symphysiolysis and disruption of the left sacroiliac joint. She presented with external rotational pelvic instability and immobilization. Prior to the injury, she received high-dose glucocorticoids for a tentative diagnosis of rheumatoid arthritis over two months. This diagnosis was not confirmed. Other causes leading to the unstable pelvic girdle were excluded by several laboratory and radiological examinations. Elevated basal cortisol and adrenocorticotropic hormone levels were measured and subsequent corticotropin-releasing hormone stimulation, dexamethasone suppression test, and petrosal sinus sampling verified the diagnosis of adrenocorticotropic hormone-dependent Cushing’s disease. The combination of adrenocorticotropic hormone-dependent Cushing’s disease and the additional application of exogenous glucocorticoids is the most probable cause of a rare atraumatic rotational pelvic instability in a premenopausal patient. To the authors’ knowledge, this case presents the first description of a rotationally unstable pelvic ring fracture involving a predominantly ligamentous insufficiency in the context of combined exogenous and endogenous glucocorticoid elevation.

  16. Postirradiation changes in the pelvic wall

    International Nuclear Information System (INIS)

    Soevik, E.; Lien, H.H.; Tveit, K.M.

    1993-01-01

    MR images of 45 patients who had received radiation therapy for carcinoma of the anus or recurrent carcinoma of the rectum were reviewed with regard to postirradiation changes of the pelvic wall. High signal intensity in bone marrow on T1-weighted images due to fatty replacement was almost always observed. Presacral edema occurred in 7 of 36 patients who were examined 4 to 6 weeks after the end of irradiation and was more frequent at later studies. The pelvic wall muscles showed high signal intensity on T2-weighted images compatible with edema. This finding was most frequent on studies performed more than 6 weeks after the end of irradiation. The changes subsided more than a year after radiation therapy. To avoid an erroneous diagnosis of tumor infiltration into the pelvic wall, it is important to be familiar with the normal postirradiation changes of the presacral space and the muscles. (orig.)

  17. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  18. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the hypofractionated treatment of high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Yartsev Slav

    2008-01-01

    Full Text Available Abstract Background To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT with 3-dimensional conformal radiation therapy (3DCRT in the setting of hypofractionated high-risk prostate cancer treatment. Methods 3DCRT and dIMRT/Helical Tomotherapy(HT planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. Results When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p dose, 1–3 Gy over 5/10 dose points; p Conclusion dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies.

  19. Shelf-stable food through high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Placek, V. E-mail: pla@ujv.cz; Svobodova, V.; Bartonicek, B.; Rosmus, J.; Camra, M

    2004-10-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75 deg. C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30 deg. C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Rez 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO{sub x}-containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested.

  20. High-dose processing and application to Korean space foods

    Energy Technology Data Exchange (ETDEWEB)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kim, Jae-Hun [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Byun, Myung-Woo [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kang, Sang-Wook; Choi, Gi-Hyuk [Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Lee, Ju-Woon [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of)], E-mail: sjwlee@kaeri.re.kr

    2009-07-15

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods (Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 {sup o}C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  1. Shelf-stable food through high dose irradiation

    International Nuclear Information System (INIS)

    Placek, V.; Svobodova, V.; Bartonicek, B.; Rosmus, J.; Camra, M.

    2004-01-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75 deg. C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30 deg. C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Rez 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO x -containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested

  2. High dose rate brachytherapy for the palliation of malignant dysphagia

    International Nuclear Information System (INIS)

    Homs, Marjolein Y.V.; Eijkenboom, Wilhelmina M.H.; Coen, Veronique L.M.A.; Haringsma, Jelle; Blankenstein, Mark van; Kuipers, Ernst J.; Siersema, Peter D.

    2003-01-01

    Background and purpose: High dose rate (HDR) brachytherapy is a commonly used palliative treatment for esophageal carcinoma. We evaluated the outcome of HDR brachytherapy in patients with malignant dysphagia. Material and methods: A retrospective analysis over a 10-year period was performed of 149 patients treated with HDR brachytherapy, administered in one or two sessions, at a median dose of 15 Gy. Patients were evaluated for functional outcome, complications, recurrent dysphagia, and survival. Results: At 6 weeks after HDR brachytherapy, dysphagia scores had improved from a median of 3 to 2 (n=104; P<0.001), however, dysphagia had not improved in 51 (49%) patients. Procedure-related complications occurred in seven (5%) patients. Late complications, including fistula formation or bleeding, occurred in 11 (7%) patients. Twelve (8%) patients experienced minor retrosternal pain. Median survival of the patients was 160 days with a 1-year survival rate of 15%. Procedure-related mortality was 2%. At follow-up, 55 (37%) patients experienced recurrent dysphagia. In 34 (23%) patients a metal stent was placed to relieve persistent or recurrent dysphagia. Conclusion: HDR brachytherapy is a moderately effective treatment for the palliation of malignant dysphagia. The incidence of early major complications is low, however, persistent and recurrent dysphagia occur frequently, and require often additional treatment

  3. High-dose processing and application to Korean space foods

    Science.gov (United States)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il; Kim, Jae-Hun; Byun, Myung-Woo; Kang, Sang-Wook; Choi, Gi-Hyuk; Lee, Ju-Woon

    2009-07-01

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods ( Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 °C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  4. Tungsten and carbon surface change under high dose plasma exposure

    International Nuclear Information System (INIS)

    Martynenko, Y.V.; Khripunov, B.I.; Petrov, V.B.

    2009-01-01

    Study of surface composition dynamics has been made on the LENTA linear plasma simulator. Experiments have been made on tungsten and carbon materials subjected to steady-state plasma exposure. The achieved ion doses on the surface were 10 21 ion cm -2 . WL 10 tungsten containing 1% of La2O3 oxide and titanium-doped graphite RG-T were studied. The following experimental conditions were varied in these experiments: energy of ions, surface temperature, working gas. Irradiations of tungsten WL 10 were executed in deuterium plasma at low ion energies (about 20 eV) and at 200 eV for temperatures below 340 K. Graphite RG-T was exposed at 1300 K. Elevated surface temperature (about 1050K) was also characteristic of experiments on tungsten sample under nitrogen plasma impact (simulated inter-ELMs condition). Surface microstructure modification has been observed and surface composition changes were found on the materials showing influence of high dose plasma irradiations on element redistribution in the near surface layers. (author)

  5. High-dose processing and application to Korean space foods

    International Nuclear Information System (INIS)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il; Kim, Jae-Hun; Byun, Myung-Woo; Kang, Sang-Wook; Choi, Gi-Hyuk; Lee, Ju-Woon

    2009-01-01

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods (Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 o C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  6. Concept and computation of radiation dose at high energies

    International Nuclear Information System (INIS)

    Sarkar, P.K.

    2010-01-01

    Computational dosimetry, a subdiscipline of computational physics devoted to radiation metrology, is determination of absorbed dose and other dose related quantities by numbers. Computations are done separately both for external and internal dosimetry. The methodology used in external beam dosimetry is necessarily a combination of experimental radiation dosimetry and theoretical dose computation since it is not feasible to plan any physical dose measurements from inside a living human body

  7. Retrospective review of pelvic malignancies undergoing total pelvic exenteration

    Directory of Open Access Journals (Sweden)

    Kuhrt Maureen P

    2012-06-01

    Full Text Available Abstract Background In patients with locally advanced or recurrent pelvic malignancies, total pelvic exenteration (TPE may be necessary for curative treatment. Despite improvements in mortality rates since TPE was first described, morbidity rates remain high due to the extensive resection and the aggressiveness of these tumors. We have studied the outcomes of TPE surgery performed at our institution. Methods Fifty-three patients with various pelvic pathologies underwent TPE between 2004 and 2010. Patients were divided into two groups based on pathology: colorectal (n = 36 versus non-colorectal (n = 17 malignancies. Demographics, operative reports, pathology reports, periprocedural events, and outcomes were analyzed. Comparison of the two groups was performed using student’s t-test and Fisher’s exact test. Survival curves were constructed using the Kaplan–Meier method and compared using the log rank test. Results The colorectal and non-colorectal groups were similar in demographics, operative times, length of stay, estimated blood loss, and rates of preoperative and intraoperative radiation use. Chemotherapy use was increased in the colorectal group compared with the non-colorectal group (55.6% vs. 23.5%, P = 0.04. Complication rates were similar: 86% in the colorectal group and 76% in the non-colorectal group. In the colorectal group, 27.8% of patients developed perineal abscesses, whereas no patients developed these complications in the non-colorectal group (P = 0.02. No survival difference was seen in primary versus recurrent colorectal tumors; however, within the colorectal group there was a survival advantage when comparing R0 resection to R1 and R2 resection combined. Median survival rates were 27.3 months for R0 resection and 10.7 months for R1 and R2 resection combined. The median survival was 21.4 months for the colorectal group and 6.9 months for the non-colorectal group (P = 0.002. Conclusions

  8. Haemodynamically Unstable Pelvic Fractures

    Science.gov (United States)

    2009-01-01

    through the pubic symphysis, and posteriorlywith the sacrum forming the sacroiliac (SI) joints (Fig. 1). The SI joints are the strongest in the body...Gardner MJ, Kendoff D, Ostermeier S, et al. Sacroiliac joint compression using an anterior pelvic compressor: a mechanical study in synthetic bone. J

  9. Chronic pelvic pain

    African Journals Online (AJOL)

    misdiagnoses, inappropriate or inadequate treatment strategies, and poor patient compliance .... excitation tenderness implies an active pelvic inflammatory process. Pain localising to ... neoplastic process, particularly cervical cancer, must be excluded. .... The dosage should be started at 10 mg at night, and increased by 5 ...

  10. Pelvic Inflammatory Disease (PID)

    Science.gov (United States)

    ... a serious condition, in women. 1 in 8 women with a history of PID experience difficulties getting pregnant. You can prevent PID if you know how to protect yourself. What is PID? Pelvic inflammatory disease is an infection of a woman’s reproductive organs. It is a complication often caused ...

  11. High-Dose Atomoxetine Treatment of ADHD in Youths with Limited Response to Standard Doses

    Science.gov (United States)

    Kratochvil, Christopher J.; Michelson, David; Newcorn, Jeffrey H.; Weiss, Margaret D.; Busner, Joan; Moore, Rodney J.; Ruff, Dustin D.; Ramsey, Janet; Dickson, Ruth; Turgay, Atilla; Saylor, Keith E.; Luber, Stephen; Vaughan, Brigette; Allen, Albert J.

    2007-01-01

    Objective: To assess the utility and tolerability of higher than standard atomoxetine doses to treat attention-deficit/hyperactivity disorder (ADHD). Method: Two randomized, double-blind trials of atomoxetine nonresponders ages 6 to 16 years were conducted comparing continued treatment with same-dose atomoxetine to treatment using greater than…

  12. Surface sputtering in high-dose Fe ion implanted Si

    International Nuclear Information System (INIS)

    Ishimaru, Manabu

    2007-01-01

    Microstructures and elemental distributions in high-dose Fe ion implanted Si were characterized by means of transmission electron microscopy and Rutherford backscattering spectroscopy. Single crystalline Si(0 0 1) substrates were implanted at 350 deg. C with 120 keV Fe ions to fluences ranging from 0.1 x 10 17 to 4.0 x 10 17 /cm 2 . Extensive damage induced by ion implantation was observed inside the substrate below 1.0 x 10 17 /cm 2 , while a continuous iron silicide layer was formed at 4.0 x 10 17 /cm 2 . It was found that the spatial distribution of Fe projectiles drastically changes at the fluence between 1.0 x 10 17 and 4.0 x 10 17 /cm 2 due to surface sputtering during implantation

  13. High-dose erythropoietin in patients with progressive multiple sclerosis

    DEFF Research Database (Denmark)

    Schreiber, Karen; Magyari, Melinda; Sellebjerg, Finn

    2017-01-01

    BACKGROUND: Erythropoietin (EPO) is a part of an endogenous neuroprotective system in the brain and may address pathophysiological mechanisms in progressive multiple sclerosis (MS). OBJECTIVE: To evaluate a treatment effect of EPO on progressive MS. METHODS: This was a single-center, randomized......, double-blind, placebo-controlled phase 2 trial, in which 52 patients with secondary or primary progressive MS were allocated to treatment with recombinant EPO (48,000 IU) or placebo, administered intravenously 17 times during 24 weeks. Patients had an Expanded Disability Status Score (EDSS) from 4 to 6......: This study provides class II evidence that treatment with high-dose EPO is not an effective treatment in patients with moderately advanced progressive MS....

  14. Safety handling manual for high dose rate remote afterloading system

    International Nuclear Information System (INIS)

    1999-01-01

    This manual is mainly for safety handling of 192 Ir-RALS (remote afterloading system) of high dose rate and followings were presented: Procedure and document format for the RALS therapy and for handling of its radiation source with the purpose of prevention of human errors and unexpected accidents, Procedure for preventing errors occurring in the treatment schedule and operation, and Procedure and format necessary for newly introducing the system into a facility. Consistency was intended in the description with the quality assurance guideline for therapy with small sealed radiation sources made by JASTRO (Japan Society for Therapeutic Radiology and Oncology). Use of the old type 60 Co-RALS was pointed out to be a serious problem remained and its safety handling procedure was also presented. (K.H.)

  15. Pharmacokinetics of high-dose intravenous melatonin in humans

    DEFF Research Database (Denmark)

    Andersen, Lars P H; Werner, Mads U; Rosenkilde, Mette Marie

    2016-01-01

    This crossover study investigated the pharmacokinetics and adverse effects of high-dose intravenous melatonin. Volunteers participated in 3 identical study sessions, receiving an intravenous bolus of 10 mg melatonin, 100 mg melatonin, and placebo. Blood samples were collected at baseline and 0, 60......, 120, 180, 240, 300, 360, and 420 minutes after the bolus. Quantitative determination of plasma melatonin concentrations was performed using a radioimmunoassay technique. Pharmacokinetic parameters were estimated by a compartmental pharmacokinetic analysis. Adverse effects included assessments...... of sedation and registration of other symptoms. Sedation, evaluated as simple reaction times, was measured at baseline and 120, 180, 300, and 420 minutes after the bolus. Twelve male volunteers completed the study. Median (IQR) Cmax after the bolus injections of 10 mg and 100 mg of melatonin were 221...

  16. Calibration of {sup 192}Ir high dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Marechal, M H [Instituto de Radioprotecao e Dozimetria, Rio de Jainero (Brazil); Almeida, C.E. de [Laboratorio de Ciencias Radiologicas, UERL, Rio de Janeiro (Brazil); Sibata, C H [Roswell Park Cancer Inst., Buffalo, NY (United States)

    1996-08-01

    A method for calibration of high dose rate sources used in afterloading brachytherapy systems is described. The calibration for {sup 192}Ir is determined by interpolating {sup 60}Co gamma-rays and 250 kV x-rays calibration factors. All measurements were done using the same build up caps as described by Goetsch et al and recommended by AAPM. The attenuation correction factors were determined to be 0.9903, 0.9928 and 0.9993 for {sup 192}Ir, {sup 60}Co and 250 kV x-ray, respectively. A wall + cap thickness of 0.421 g.cm{sup -2} is recommended for all measurements to ensure electronic equilibrium for {sup 60}Co and {sup 192}Ir gamma-ray beams. A mathematical formalism is described for determination of (N{sub x}){sub Ir}. (author). 5 refs, 1 fig.

  17. 192Ir high dose rate (HDR) interstitial brain implant: optimisation

    International Nuclear Information System (INIS)

    Tyagi, Anuj; Singh, Dinesh; Chitra, S.; Gupta, J.P.

    2001-01-01

    The new modality of stepping source dosimetry system (SSDs) illustrates a remarkable improvement in attaining the uniform and homogeneous dose distribution within the target volume. The technique enables the physicist to correct for a certain amount of misplacement or curvature of implant geometry. The short course of brachytherapy provides good palliation in terms of functional improvements with low and acceptable toxicity in high-grade glioma. With continual refinements of the technique, brachytherapy performed by a skilled brachytherapy team offers an opportunity to improve patient survival and quality of life. Since 1997, micro selectron HDR 192 Ir treatments are done including gynecological, oesophageal, breast, surface mould, soft tissue sarcoma (STS) and brain in our hospital. In this paper, procedure of interstitial brain implant in glioma as implant technique, simulation and treatment planning will be discussed

  18. High dose rate brachytherapy for superficial cancer of the esophagus

    International Nuclear Information System (INIS)

    Maingon, Philippe; D'Hombres, Anne; Truc, Gilles; Barillot, Isabelle; Michiels, Christophe; Bedenne, Laurent; Horiot, Jean Claude

    2000-01-01

    Purpose: We analyzed our experience with external radiotherapy, combined modality treatment, or HDR brachytherapy alone to limited esophageal cancers. Methods and Materials: From 1991 to 1996, 25 patients with limited superficial esophagus carcinomas were treated by high dose rate brachytherapy. The mean age was 63 years (43-86 years). Five patients showed superficial local recurrence after external radiotherapy. Eleven patients without invasion of the basal membrane were staged as Tis. Fourteen patients with tumors involving the submucosa without spreading to the muscle were staged as T1. Treatment consisted of HDR brachytherapy alone in 13 patients, external radiotherapy and brachytherapy in 8 cases, and concomitant chemo- and radiotherapy in 4 cases. External beam radiation was administered to a total dose of 50 Gy using 2 Gy daily fractions in 5 weeks. In cases of HDR brachytherapy alone (13 patients), 6 applications were performed once a week. Results: The mean follow-up is 31 months (range 24-96 months). Twelve patients received 2 applications and 13 patients received 6 applications. Twelve patients experienced a failure (48%), 11/12 located in the esophagus, all of them in the treated volume. One patient presented an isolated distant metastasis. In the patients treated for superficial recurrence, 4/5 were locally controlled (80%) by brachytherapy alone. After brachytherapy alone, 8/13 patients were controlled (61%). The mean disease-free survival is 14 months (1-36 months). Overall survival is 76% at 1 year, 37% at 2 years, and 14% at 3 years. Overall survival for Tis patients is 24% vs. 20% for T1 (p 0.83). Overall survival for patients treated by HDR brachytherapy alone is 43%. One patient presented with a fistula with local failure after external radiotherapy and brachytherapy. Four stenosis were registered, two were diagnosed on barium swallowing without symptoms, and two required dilatations. Conclusion: High dose rate brachytherapy permits the treating

  19. "Time sequential high dose of Cytarabine in acute myelocytic leukemia "

    Directory of Open Access Journals (Sweden)

    Ghavamzadeh A

    2003-05-01

    Full Text Available Given preliminary evidence of timed, sequential chemotherapy of high dose cytosine arabinoside the current study was initiated to assess the side effects and efficacy of this regimen in patients with newly acute myelocytic leukemia (AML. Nineteen adults who referred to Hematology-Oncology and Bone Marrow Transplantation (BMT research center of Tehran University of Medical Sciences were enrolled in a trial from Aug 1999 to Nov 2000. All patients had a Karnofski classification above 60%. At this time induction therapy consisted of daunorubicin or idarubicin given at a dose of 60 mg/m² and 12 mg/m² IV respectively on days 1-3, and cytarabine (Ara-C 100 mg/m² intravenously by continuous infusion on days 1-7, followed by Ara-C 1000 mg/m² given on day 8-10 every 12 hours by IV infusion. Consolidation therapy started after 35th day. Of 19 fully evaluable patients, 10 patients achieved a complete remission, whereas 36.6% patients succumbed to death due to regeneration failure. The clinical data show that the overall survival rate from diagnosis 55.5% (95% CI, 30.8-78.5 at 6 months for the entire cohort of the patients. Disease free survival is also 50% (95% CI, 26-74. Mean duration of death due to treatment was 20 days (range 17-29 after beginning the regimen. Presenting WBC counts, French-American-British (FAB classification, sex and age were not useful prognostic variables. Fever, diarrhea, nausea and vomiting and GI hemorrhage were seen in 19, 6, 4, 7 patients respectively. It seems the 3+7+3 regimen is a promising approach for the AML patients regarding to high complete remission rate, but more supportive care should be considered. Furthermore any, benefit in long-term outcome can’t be determined regardless to the choice of post remission therapy (e.g., GCSF, appropriate antibiotics and etc.

  20. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tome, Wolfgang A. [Department of Human Oncology, University of Wisconsin-Madison, WI, 53792 (United States); Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC 3002 (Australia) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Human Oncology, University of Wisconsin-Madison, WI 53792 (United States); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia) and Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Einstein Institute of Oncophysics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York 10461 (United States) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2012-08-15

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  1. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tomé, Wolfgang A.

    2012-01-01

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed “Super Sampling” involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  2. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  3. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  4. The Comparison of Two Types of Treatment (High Dose and Low Dose IVIG in Children with GBS in Mofid Hospital

    Directory of Open Access Journals (Sweden)

    Parvaneh Karim-Zadeh

    2003-12-01

    Full Text Available Objective: Acute inflammatory demyelinating peripheral neuropathy (Guillain-Barre-Syndrome is by far the most common cause of immune–mediated peripheral nerve disease in children and with the near disappearance of poliomyelitis, is responsible for the great majority of cases of acute flaccid paralysis. Several controlled studies have done with corticosteroids, plasma pheresis and IVIG in pediatric patients. IVIG treatment can be done in two types of treatment: 1- High dose that means 1gr/kg/day for 2 days. 2- Low dose that means 400mg/kg/day for 5 days. Several studies in other countries have shown faster rate of recovery in patients who received total dose of IVIG in 2 days as opposed to 5 days. Materials & Methods: Because we have not any study about this two types of treatment in IRAN we decided to comparison this two types of IVIG treatment. So the patients that referred to Mofid children hospital for weakness and we diagnosed GBS (with history, physical examination, laboratories and EMG-NCV are divided in two groups: 1- High dose IVIG treatment (experimental group. 2- Low dose IVIG treatment (control group Then the results evaluated. Results: Our findings included that in high dose IVIG therapy we have faster rate of recovery and the Hospital stay is shorter than low dose IVIG-therapy. Also in this type of treatment “because the patients cure faster” , so complications are decreased in them. In the group of high dose IVIG therapy, lower and upper extremities weakness decreased in time. Conclusion: We did not receive any relationship between side effects of drugs and the type of treatment. The relationship between high dose IVIG therapy and drug side effects was not significant.

  5. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  6. Inverse Planned High-Dose-Rate Brachytherapy for Locoregionally Advanced Cervical Cancer: 4-Year Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Tinkle, Christopher L.; Weinberg, Vivian [Department of Radiation Oncology, University of California, San Francisco, California (United States); Chen, Lee-May [Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California, San Francisco, California (United States); Littell, Ramey [Gynecologic Oncology, The Permanente Medical Group, San Francisco, California (United States); Cunha, J. Adam M.; Sethi, Rajni A. [Department of Radiation Oncology, University of California, San Francisco, California (United States); Chan, John K. [Gynecologic Oncology, California Pacific Medical Center, San Francisco, California (United States); Hsu, I-Chow, E-mail: ichow.hsu@ucsf.edu [Department of Radiation Oncology, University of California, San Francisco, California (United States)

    2015-08-01

    Purpose: Evaluate the efficacy and toxicity of image guided brachytherapy using inverse planning simulated annealing (IPSA) high-dose-rate brachytherapy (HDRB) boost for locoregionally advanced cervical cancer. Methods and Materials: From December 2003 through September 2009, 111 patients with primary cervical cancer were treated definitively with IPSA-planned HDRB boost (28 Gy in 4 fractions) after external radiation at our institution. We performed a retrospective review of our experience using image guided brachytherapy. Of the patients, 70% had a tumor size >4 cm, 38% had regional nodal disease, and 15% had clinically evident distant metastasis, including nonregional nodal disease, at the time of diagnosis. Surgical staging involving pelvic lymph node dissection was performed in 15% of patients, and 93% received concurrent cisplatin-based chemotherapy. Toxicities are reported according to the Common Terminology Criteria for Adverse Events version 4.0 guidelines. Results: With a median follow-up time of 42 months (range, 3-84 months), no acute or late toxicities of grade 4 or higher were observed, and grade 3 toxicities (both acute and late) developed in 8 patients (1 constitutional, 1 hematologic, 2 genitourinary, 4 gastrointestinal). The 4-year Kaplan-Meier estimate of late grade 3 toxicity was 8%. Local recurrence developed in 5 patients (4 to 9 months after HDRB), regional recurrence in 3 (6, 16, and 72 months after HDRB), and locoregional recurrence in 1 (4 months after HDR boost). The 4-year estimates of local, locoregional, and distant control of disease were 94.0%, 91.9%, and 69.1%, respectively. The overall and disease-free survival rates at 4 years were 64.3% (95% confidence interval [CI] of 54%-73%) and 61.0% (95% CI, 51%-70%), respectively. Conclusions: Definitive radiation by use of inverse planned HDRB boost for locoregionally advanced cervical cancer is well tolerated and achieves excellent local control of disease. However, overall

  7. Reconstructive options in pelvic tumours

    Directory of Open Access Journals (Sweden)

    Mayilvahanan N

    2005-01-01

    Full Text Available Background: Pelvic tumours present a complex problem. It is difficult to choose between limb salvage and hemipelvectomy. Method: Forty three patients of tumours of pelvis underwent limb salvage resection with reconstruction in 32 patients. The majority were chondrosarcomas (20 cases followed by Ewing sarcoma. Stage II B was the most common stage in malignant lesions and all the seven benign lesions were aggressive (B3. Surgical margins achieved were wide in 31 and marginal in 12 cases. Ilium was involved in 51% of cases and periacetabular involvement was seen in 12 patients. The resections done were mostly of types I &II of Enneking′s classification of pelvic resection. Arthrodesis was attempted in 24 patients. Customized Saddle prosthesis was used in seven patients and no reconstruction in 12 patients. Adjuvant chemotherapy was given to all high-grade malignant tumours, combined with radiotherapy in 7 patients. Results: With a mean follow up of 48.5 months and one patient lost to follow up, the recurrence rate among the evaluated cases was 16.6%. Oncologically, 30 patients were continuously disease free with 7 local recurrences and 4 deaths due to disseminated disease and 2 patients died of other causes. During the initial years, satisfactory functional results were achieved with prosthetic replacement. Long-term functional result of 36 patients who were alive at the time of latest follow up was satisfactory in 75% who underwent arthrodesis and in those where no reconstruction was used. We also describe a method of new classification of pelvic resections that clarifies certain shortcomings of the previous systems of classification. Conclusion: Selection of a procedure depends largely on the patient factors, the tumour grade, the resultant defect and the tissue factors. Resection with proper margins gives better functional and oncological results

  8. Urethral stricture following high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Sullivan, Lisa; Williams, Scott G.; Tai, Keen Hun; Foroudi, Farshad; Cleeve, L.; Duchesne, Gillian M.

    2009-01-01

    Purpose: To evaluate the incidence, timing, nature and outcome of urethral strictures following high dose rate brachytherapy (HDRB) for prostate carcinoma. Methods and materials: Data from 474 patients with clinically localised prostate cancer treated with HDRB were analysed. Ninety percent received HDRB as a boost to external beam radiotherapy (HDRBB) and the remainder as monotherapy (HDRBM). Urethral strictures were graded according to the Common Terminology Criteria for Adverse Events v3.0. Results: At a median follow-up of 41 months, 38 patients (8%) were diagnosed with a urethral stricture (6-year actuarial risk 12%). Stricture location was bulbo-membranous (BM) urethra in 92.1%. The overall actuarial rate of grade 2 or more BM urethral stricture was estimated at 10.8% (95% CI 7.0-14.9%), with a median time to diagnosis of 22 months (range 10-68 months). All strictures were initially managed with either dilatation (n = 15) or optical urethrotomy (n = 20). Second line therapy was required in 17 cases (49%), third line in three cases (9%) and 1 patient open urethroplasty (grade 3 toxicity). Predictive factors on multivariate analysis were prior trans-urethral resection of prostate (hazard ratio (HR) 2.81, 95% CI 1.15-6.85, p = 0.023); hypertension (HR 2.83, 95% CI 1.37-5.85, p = 0.005); and dose per fraction used in HDR (HR for 1 Gy increase per fraction 1.33, 95% CI 1.08-1.64, p = 0.008). Conclusions: BM urethral strictures are the most common late grade 2 or more urinary toxicity following HDR brachytherapy for prostate cancer. Most are manageable with minimally invasive procedures. Both clinical and dosimetric factors appear to influence the risk of stricture formation.

  9. Dosimetric Considerations to Determine the Optimal Technique for Localized Prostate Cancer Among External Photon, Proton, or Carbon-Ion Therapy and High-Dose-Rate or Low-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Georg, Dietmar; Hopfgartner, Johannes; Gòra, Joanna; Kuess, Peter; Kragl, Gabriele; Berger, Daniel; Hegazy, Neamat; Goldner, Gregor; Georg, Petra

    2014-01-01

    Purpose: To assess the dosimetric differences among volumetric modulated arc therapy (VMAT), scanned proton therapy (intensity-modulated proton therapy, IMPT), scanned carbon-ion therapy (intensity-modulated carbon-ion therapy, IMIT), and low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy (BT) treatment of localized prostate cancer. Methods and Materials: Ten patients were considered for this planning study. For external beam radiation therapy (EBRT), planning target volume was created by adding a margin of 5 mm (lateral/anterior–posterior) and 8 mm (superior–inferior) to the clinical target volume. Bladder wall (BW), rectal wall (RW), femoral heads, urethra, and pelvic tissue were considered as organs at risk. For VMAT and IMPT, 78 Gy(relative biological effectiveness, RBE)/2 Gy were prescribed. The IMIT was based on 66 Gy(RBE)/20 fractions. The clinical target volume planning aims for HDR-BT ( 192 Ir) and LDR-BT ( 125 I) were D 90% ≥34 Gy in 8.5 Gy per fraction and D 90% ≥145 Gy. Both physical and RBE-weighted dose distributions for protons and carbon-ions were converted to dose distributions based on 2-Gy(IsoE) fractions. From these dose distributions various dose and dose–volume parameters were extracted. Results: Rectal wall exposure 30-70 Gy(IsoE) was reduced for IMIT, LDR-BT, and HDR-BT when compared with VMAT and IMPT. The high-dose region of the BW dose–volume histogram above 50 Gy(IsoE) of IMPT resembled the VMAT shape, whereas all other techniques showed a significantly lower high-dose region. For all 3 EBRT techniques similar urethra D mean around 74 Gy(IsoE) were obtained. The LDR-BT results were approximately 30 Gy(IsoE) higher, HDR-BT 10 Gy(IsoE) lower. Normal tissue and femoral head sparing was best with BT. Conclusion: Despite the different EBRT prescription and fractionation schemes, the high-dose regions of BW and RW expressed in Gy(IsoE) were on the same order of magnitude. Brachytherapy techniques were clearly superior in

  10. Dosimetric Considerations to Determine the Optimal Technique for Localized Prostate Cancer Among External Photon, Proton, or Carbon-Ion Therapy and High-Dose-Rate or Low-Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Georg, Dietmar, E-mail: Dietmar.Georg@akhwien.at [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Hopfgartner, Johannes [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Gòra, Joanna [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Kuess, Peter [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Kragl, Gabriele [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Berger, Daniel [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Hegazy, Neamat [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Goldner, Gregor; Georg, Petra [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria)

    2014-03-01

    Purpose: To assess the dosimetric differences among volumetric modulated arc therapy (VMAT), scanned proton therapy (intensity-modulated proton therapy, IMPT), scanned carbon-ion therapy (intensity-modulated carbon-ion therapy, IMIT), and low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy (BT) treatment of localized prostate cancer. Methods and Materials: Ten patients were considered for this planning study. For external beam radiation therapy (EBRT), planning target volume was created by adding a margin of 5 mm (lateral/anterior–posterior) and 8 mm (superior–inferior) to the clinical target volume. Bladder wall (BW), rectal wall (RW), femoral heads, urethra, and pelvic tissue were considered as organs at risk. For VMAT and IMPT, 78 Gy(relative biological effectiveness, RBE)/2 Gy were prescribed. The IMIT was based on 66 Gy(RBE)/20 fractions. The clinical target volume planning aims for HDR-BT ({sup 192}Ir) and LDR-BT ({sup 125}I) were D{sub 90%} ≥34 Gy in 8.5 Gy per fraction and D{sub 90%} ≥145 Gy. Both physical and RBE-weighted dose distributions for protons and carbon-ions were converted to dose distributions based on 2-Gy(IsoE) fractions. From these dose distributions various dose and dose–volume parameters were extracted. Results: Rectal wall exposure 30-70 Gy(IsoE) was reduced for IMIT, LDR-BT, and HDR-BT when compared with VMAT and IMPT. The high-dose region of the BW dose–volume histogram above 50 Gy(IsoE) of IMPT resembled the VMAT shape, whereas all other techniques showed a significantly lower high-dose region. For all 3 EBRT techniques similar urethra D{sub mean} around 74 Gy(IsoE) were obtained. The LDR-BT results were approximately 30 Gy(IsoE) higher, HDR-BT 10 Gy(IsoE) lower. Normal tissue and femoral head sparing was best with BT. Conclusion: Despite the different EBRT prescription and fractionation schemes, the high-dose regions of BW and RW expressed in Gy(IsoE) were on the same order of magnitude. Brachytherapy techniques

  11. Comparison of radiation dose and image quality of Siremobil-IsoC{sup 3D} with a 16-slice spiral CT for diagnosis and intervention in the human pelvic bone; Vergleich von Strahlenexposition und Bildqualitaet eines Siremobil-IsoC{sup 3D} mit einem 16-Zeilen-Spiral-CT bei Diagnostik und Intervention am humanen Becken

    Energy Technology Data Exchange (ETDEWEB)

    Wieners, G.; Pech, M.; Beck, A.; Wust, P.; Felix, R.; Schroeder, R.J. [Klinik fuer Strahlenheilkunde, Charite, Univ. Berlin (Germany); Koenig, B.; Erdmenger, U.; Stoeckle, U. [Klinik fuer Unfallchirurgie, Charite, Univ. Berlin (Germany)

    2005-02-01

    Purpose: to compare the image quality of 16-slice computed tomography with the image quality of Siremobil-IsoC{sup 3D} of the pelvic region and to measure simultaneously the radiation dose before and after implantation of a sacroiliac screw (SI-screw) Materials and methods: the pelvic region of 8 human cadavers was examined in the Siremobil-IsoC{sup 3D} at five different levels. We used a standard protocol for the 16-slice CT of the complete pelvic region before and after insertion of a pelvic screw, followed by stepwise reduction of the tube current to find the tube current that equalizes the image quality of both modalities. We controlled the image quality by judging important structures such as neuroforamen, nerves, sacroiliacal joint space, intervertebral space, osteophytes, iliopsoas muscle, acetabular surface, fovea centralis, hip joint and os pubis. The image quality was judged by three radiologists and three trauma surgeons using a ranking from 1 to 5. The dose was measured with an endorectally placed NOMEX Dosimeter, to obtain the gonadal dose. Results: the medium score for all viewers of the Siremobil-IsoC{sup 3D} examinations was between 3 and 4.3. The medium score for all CT-examinations with a tube current of 250 mA was between 1.3 and 2.2. The reduction of tube current down to 80 mA hardly influenced the marks for the analyzed structures. Under 80 mA, bony structures, even after implantation of a SI-screw, were still marked as good, but soft tissue differentiation was getting worse. For the examination of the pelvis, the average dose-length product for the IsoC{sup 3D} was 41.2 mGy x cm. The medium dose-length product for CT was 389 mGy x cm for 250 mA, 125 mGy x cm for 80 mA and 82 mGy x cm for 60 mA. (orig.)

  12. Preliminary results of concurrent chemotherapy and radiation therapy using high-dose-rate brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ja; Lee, Ji Hye; Lee, Re Na; Suh, Hyun Suk [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34 {approx} 74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follow: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45 {approx} 50.4 Gy (median: 50.4 Gy) over 5 {approx} 5.5 weeks. Ir-192 HDR intracavity brachytherapy (ICBT) was given after a total dose of 41.1 Gy. HDR-ICBT was performed twice a week, with a fraction point. A dose of 4 Gy and median dose to point A was 28 Gy (range: 16 {approx} 32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT + ICBT) was 88 Gy{sub 10} (range:77 {approx} 94 Gy{sub 10}). The median cumulative BED at ICRU 38 reference point (EBRT + ICBT) was 131 Gy{sub 3} (range: 122 {approx} 140 Gy{sub 3}) at point A, 109 Gy{sub 3} (range:88{approx} 125 Gy{sub 3}) at the rectum and 111 Gy{sub 3} (range: 91 {approx} 123 Gy{sub 3}) at the urinary bladder. Cisplatin (60 mg/m{sup 2}) and 5-FU (1,000 mg/m{sup 2}) was administered intravenously at 2 weeks interval from the first day of radiation for median 5 (range:2 {approx} 6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range:8{approx} 50 months). The complete response rate after concurrent chemo radiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure

  13. Preliminary results of concurrent chemotherapy and radiation therapy using high-dose-rate brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Lee, Kyung Ja; Lee, Ji Hye; Lee, Re Na; Suh, Hyun Suk

    2006-01-01

    To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34 ∼ 74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follow: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45 ∼ 50.4 Gy (median: 50.4 Gy) over 5 ∼ 5.5 weeks. Ir-192 HDR intracavity brachytherapy (ICBT) was given after a total dose of 41.1 Gy. HDR-ICBT was performed twice a week, with a fraction point. A dose of 4 Gy and median dose to point A was 28 Gy (range: 16 ∼ 32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT + ICBT) was 88 Gy 10 (range:77 ∼ 94 Gy 10 ). The median cumulative BED at ICRU 38 reference point (EBRT + ICBT) was 131 Gy 3 (range: 122 ∼ 140 Gy 3 ) at point A, 109 Gy 3 (range:88∼ 125 Gy 3 ) at the rectum and 111 Gy 3 (range: 91 ∼ 123 Gy 3 ) at the urinary bladder. Cisplatin (60 mg/m 2 ) and 5-FU (1,000 mg/m 2 ) was administered intravenously at 2 weeks interval from the first day of radiation for median 5 (range:2 ∼ 6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range:8∼ 50 months). The complete response rate after concurrent chemo radiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure rate was 13% and distant metastatic rate was 3.3%. The crude rate of minor hematologic

  14. Dosing algorithm to target a predefined AUC in patients with primary central nervous system lymphoma receiving high dose methotrexate.

    Science.gov (United States)

    Joerger, Markus; Ferreri, Andrés J M; Krähenbühl, Stephan; Schellens, Jan H M; Cerny, Thomas; Zucca, Emanuele; Huitema, Alwin D R

    2012-02-01

    There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h. A population covariate model from a pooled dataset of 131 patients receiving HDMTX was used to simulate concentration-time curves of 10,000 patients and test the efficacy of a dosing algorithm based on 24 h MTX plasma concentrations to target the prespecified AUC(MTX) . These data simulations included interindividual, interoccasion and residual unidentified variability. Patients received a total of four simulated cycles of HDMTX and adjusted MTX dosages were given for cycles two to four. The dosing algorithm proposes MTX dose adaptations ranging from +75% in patients with MTX C(24) 12 µmol l(-1). The proposed dosing algorithm resulted in a marked improvement of the proportion of patients within the AUC(MTX) target between 1000 and 1100 µmol l(-1) h (11% with standard MTX dose, 35% with the adjusted dose) and a marked reduction of the interindividual variability of MTX exposure. A simple and practical dosing algorithm for HDMTX has been developed based on MTX 24 h plasma concentrations, and its potential efficacy in improving the proportion of patients within a prespecified target AUC(MTX) and reducing the interindividual variability of MTX exposure has been shown by data simulations. The clinical benefit of this dosing algorithm should be assessed in patients with primary central nervous system lymphoma (PCNSL). © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.

  15. Studies of absorbed dose determinations and spatial dose distributions for high energy proton beams

    International Nuclear Information System (INIS)

    Hiraoka, Takeshi

    1982-01-01

    Absolute dose determinations were made with three types of ionization chamber and a Faraday cup. Methane based tissue equivalent (TE) gas, nitrogen, carbon dioxide, air were used as an ionizing gas with flow rate of 10 ml per minute. Measurements were made at the entrance position of unmodulated beams and for a beam of a spread out Bragg peak at a depth of 17.3 mm in water. For both positions, the mean value of dose determined by the ionization chambers was 0.993 +- 0.014 cGy for which the value of TE gas was taken as unity. The agreement between the doses estimated by the ionization chambers and the Faraday cup was within 5%. Total uncertainty estimated in the ionization chamber and the Faraday cup determinations is 6 and 4%, respectively. Common sources of error in calculating the dose from ionization chamber measurements are depend on the factors of ion recombination, W value, and mass stopping power ratio. These factors were studied by both experimentally and theoretically. The observed values for the factors show a good agreement to the predicted one. Proton beam dosimetry intercomparison between Japan and the United States was held. Good agreement was obtained with standard deviation of 1.6%. The value of the TE calorimeter is close to the mean value of all. In the proton spot scanning system, lateral dose distributions at any depth for one spot beam can be simulated by the Gaussian distribution. From the Gaussian distributions and the central axis depth doses for one spot beam, it is easy to calculate isodose distributions in the desired field by superposition of dose distribution for one spot beam. Calculated and observed isodose curves were agreed within 1 mm at any dose levels. (J.P.N.)

  16. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige [Kinki Univ., Atomic Energy Research Institute, Osaka (Japan); Tatsumi, Kusuo [Kinki Univ., Life Science Research Institute, Osaka (Japan); Nakai, Sayaka; Sugahara, Tsutomu [Health Research Foundation, Kyoto (Japan); Yuan Yongling [Labor Hygiene Institute of Hunan Prov. (China); Wei Luxin [Laboratory of Industorial Hygiene, Ministry of Health (China)

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: (1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. (2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  17. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    International Nuclear Information System (INIS)

    Koga, Taeko; Morishima, Hiroshige; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: 1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. 2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  18. Novel high dose rate lip brachytherapy technique to improve dose homogeneity and reduce toxicity by customized mold

    International Nuclear Information System (INIS)

    Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay

    2014-01-01

    The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a “sandwich” technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the “sandwich” technique to “classic” – interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue “hot spots” and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36–81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1–47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality

  19. Functional imaging of the pelvic floor

    Energy Technology Data Exchange (ETDEWEB)

    Lienemann, Andreas E-mail: andreaslienemann@web.de; Fischer, Tanja

    2003-08-01

    Introduction/Objective: Pelvic floor dysfunction and associated pelvic organ prolapse represent a major problem in our present-day society, mostly afflicting parous women. Magnetic resonance imaging (MRI) is assuming an increasingly important role in the more accurate delineation of the extent of the problem. This article briefly reviews one of the main radiological methods for the dynamic evaluation of the pelvic floor: functional cine MRI. Methods and Material: Out of the literature the smallest common denominator for functional cine MRI can be defined as follows: high field system; patient either in supine or sitting position; fast gradient echo sequence; midsagittal slice orientation; either a stack of slices or repeated measurements at the same slice position with the patient at rest or straining; image analysis using the pubococcygeal reference line. Results: All except two publications stress the usefulness of functional cine MRI in the evaluation of patients with organ descent and prolapse. This well accepted method allows for the visualization of all relevant structures in the anterior, middle and posterior compartment. It is especially useful in the detection of enteroceles, and provides a reliable postoperative follow-up tool. Isolated urinary or stool incontinence are not an indication for functional cine MRI, as is the case in patients with equivocal clinical findings. To date it does not allow for real 3D imaging of the pelvic floor or sufficient determination of fascial defects. Discussion: Functional cine MRI of the pelvic floor is a promising new imaging method for the detection of organ descent and prolapse in patients with equivocal clinical findings. The combination of function and morphology allows for an innovative view of the pelvic floor, and thus adds to our understanding of the various interactions of the structures.

  20. High-dose-rate afterloading brachytherapy in carcinoma of the cervix: an experience of 1992 patients

    International Nuclear Information System (INIS)

    Lorvidhaya, Vicharn; Tonusin, Anun; Changwiwit, Witit; Chitapanarux, Imjai; Srisomboon, Jatupol; Wanwilairat, Somsak; Chawapun, Nisa; Sukthomya, Vimol

    2000-01-01

    Purpose: To report the results of radiation therapy in carcinoma of the cervix treated by external irradiation and high-dose-rate (HDR) intracavitary brachytherapy. Methods and Materials: This is a retrospective analysis of 2063 patients with histologically proven carcinoma of the cervix treated by external irradiation and HDR intracavitary brachytherapy between March 1985-December 1991. The Kaplan-Meier method was used for survival and disease-free survival analysis. Late complications in the bowel and bladder were calculated actuarially. Results: There were 71 patients who did not complete the course of irradiation so only 1992 patients were retrospectively analyzed for survival. There were 2 patients (0.1%) in Stage IA, 211 (10.2%) Stage IB, 225 (10.9%) in Stage IIA, 902 (43.7%) in Stage IIB, 14 (0.7%) in Stage IIIA, 675 (32.7%) in Stage IIIB, 16 (0.8%) in Stage IVA, and 16 (0.8%) in Stage IVB. The median follow-up time was 96 months. The actuarial 5-year disease-free survival rate was 79.5%, 70.0%, 59.4%, 46.1%, 32.3%, 7.8%, and 23.1% for Stage IB, IIA, IIB, IIIA, IIIB, IVA, and IVB respectively. The actuarial 5-year disease-free survival rate for Stage IB 1 and IB 2 squamous cell carcinoma was 88.7% and 67.0%. The actuarial 5-year overall survival rate was 86.3%, 81.1%, 73.0%, 50.3%, 47.8%, 7.8%, and 30.8% for Stage IB, IIA, IIB, IIIA, IIIB, IVA, and IVB respectively. Pattern of failure revealed 20.8% local recurrence, 18.7% distant metastases, and 4% in both. The late complication rate Grade 3 and 4 (RTOG) for bowel and bladder combined was 7.0% with 1.9% Grade 4. Conclusion: HDR brachytherapy used in this series produced pelvic control and survival rates comparable to other LDR series

  1. Comparative study of SOI/Si hybrid substrates fabricated using high-dose and low-dose oxygen implantation

    International Nuclear Information System (INIS)

    Dong Yemin; Chen Meng; Chen Jing; Wang Xiang; Wang Xi

    2004-01-01

    Hybrid substrates comprising both silicon-on-insulator (SOI) and bulk Si regions have been fabricated using the technique of patterned separation by implantation of oxygen (SIMOX) with high-dose (1.5 x 10 18 cm -2 ) and low-dose ((1.5-3.5) x 10 17 cm -2 ) oxygen ions, respectively. Cross-sectional transmission electron microscopy (XTEM) was employed to examine the microstructures of the resulting materials. Experimental results indicate that the SOI/Si hybrid substrate fabricated using high-dose SIMOX is of inferior quality with very large surface height step and heavily damaged transitions between the SOI and bulk regions. However, the quality of the SOI/Si hybrid substrate is enhanced dramatically by reducing the implant dose. The defect density in transitions is reduced considerably. Moreover, the expected surface height difference does not exist and the surface is exceptionally flat. The possible mechanisms responsible for the improvements in quality are discussed

  2. Dose-dependent high-resolution electron ptychography

    International Nuclear Information System (INIS)

    D'Alfonso, A. J.; Allen, L. J.; Sawada, H.; Kirkland, A. I.

    2016-01-01

    Recent reports of electron ptychography at atomic resolution have ushered in a new era of coherent diffractive imaging in the context of electron microscopy. We report and discuss electron ptychography under variable electron dose conditions, exploring the prospects of an approach which has considerable potential for imaging where low dose is needed

  3. Mutation process at low or high radiation doses

    International Nuclear Information System (INIS)

    Abrahamson, S.; Wisconsin Univ., Madison

    1976-01-01

    A concise review is given of the status of research on the genetic effects of low-level radiation in general. The term ''low dose'' is defined and current theories on low dose are set out. Problems and their solutions are discussed. (author)

  4. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  5. Sagittal spino-pelvic adjustment in severe Lenke 1 hypokyphotic adolescent idiopathic scoliosis patients.

    Science.gov (United States)

    Vidal, Christophe; Mazda, Keyvan; Ilharreborde, Brice

    2016-10-01

    The human standing position requires permanent reciprocal spino-pelvic adjustments to obtain a dynamic and economic posture. This study focuses on a hypokyphotic Lenke 1 adolescent idiopathic scoliosis (AIS) patients cohort and points out their particular lumbo-pelvic adaptive mechanisms to maintain a neutral sagittal balance. Preoperative retrospective analysis of prospectively collected data on a monocentric cohort of 455 AIS patients planned for corrective surgery. Radiological low-dose system coupled with a validated clinical routine software allowed to obtain data from eighty-four hypokyphotic [thoracic kyphosis (TK) <20°] Lenke 1 patients and were separately analyzed. Bilateral Student and one-way ANOVAs were conducted for statistical analysis. Mean Cobb angle was 46.3° (±7.2), TK was 11° (±7.1), sagittal vertical axis (SVA) was -10.1 mm (±30.9), pelvic incidence (PI) was 55.7° (±12.9). Fifty percents of patients were posteriorly imbalanced. Among them, patients with a low PI used an anteversion of their pelvis [indicated by a high pelvic tilt (PT) angle] but were not able to increase their lumbar lordosis (LL) to minimize the posterior spinal shift. Hypokyphotic Lenke 1 AIS patients use lumbo-pelvic compensatory mechanisms to maintain their global balance with a poor effectiveness. Subjects with a low PI have a restricted range of LL adaptation. Attention should be paid during surgical planning not to overcorrect lordosis in the instrumented levels in case of non-selective fusion, that may induce posterior shift of the fusion mass and expose to junctional syndromes and poor functional outcomes in this particular patients.

  6. Comparison of traditional low-dose-rate to optimized and nonoptimized high-dose-rate tandem and ovoid dosimetry

    International Nuclear Information System (INIS)

    Decker, William E.; Erickson, Beth; Albano, Katherine; Gillin, Michael

    2001-01-01

    Purpose: Few dose specification guidelines exist when attempting to perform high-dose-rate (HDR) dosimetry. The purpose of this study was to model low-dose-rate (LDR) dosimetry, using parameters common in HDR dosimetry, to achieve the 'pear-shape' dose distribution achieved with LDR tandem and ovoid applications. Methods and Materials: Radiographs of Fletcher-Suit LDR applicators and Nucletron 'Fletcher-like' HDR applicators were taken with the applicators in an idealized geometry. Traditional Fletcher loadings of 3M Cs-137 sources and the Theratronics Planning System were used for LDR dosimetry. HDR dosimetry was performed using the Nucletron Microselectron HDR UPS V11.22 with an Ir-192 source. Dose optimization points were initially located along a line 2 cm lateral to the tandem, beginning at the tandem tip at 0.5-cm intervals, ending at the sail, and optimized to 100% of the point A dose. A single dose optimization point was also placed laterally from the center of each ovoid equal to the radius of the ovoid (ovoid surface dose). For purposes of comparison, dose was also calculated for points A and B, and a point located 1 cm superior to the tandem tip in the plane of the tandem, (point F). Four- and 6-cm tandem lengths and 2.0-, 2.5-, and 3.0-cm ovoid diameters were used for this study. Based on initial findings, dose optimization schemes were developed to best approximate LDR dosimetry. Finally, radiographs were obtained of HDR applications in two patients. These radiographs were used to compare the optimization schemes with 'nonoptimized' treatment plans. Results: Calculated doses for points A and B were similar for LDR, optimized HDR, and nonoptimized HDR. The optimization scheme that used tapered dose points at the tandem tip and optimized a single ovoid surface point on each ovoid to 170% of point A resulted in a good approximation of LDR dosimetry. Nonoptimized HDR resulted in higher doses at point F, the bladder, and at points lateral to the tandem tip

  7. Dose finding study of granisetron in patients receiving high-dose cisplatin chemotherapy. The Granisetron Study Group.

    Science.gov (United States)

    Riviere, A.

    1994-01-01

    The efficacy and safety of three different doses of granisetron (2 micrograms kg-1, group A; 10 micrograms kg-1, group B; 40 micrograms kg-1, group C) were compared in a randomised, double-blind study of 157 patients due to receive high-dose cisplatin therapy (mean dose > 97 mg m-2). In each group, up to two 3 mg rescue doses of granisetron were allowed if more than mild nausea or vomiting occurred. In group A 30.8%, in group B 61.5% and in group C 67.9% of patients were complete responders (i.e. no vomiting or nothing worse than mild nausea) during the first 24 h. These differences are significant between groups A and B, and A and C. There were no statistically significant differences in any efficacy variable between the 10 micrograms kg-1 and 40 micrograms kg-1 groups, although in each case the trend favoured the higher dose. Additional rescue doses resulted in resolved or improved symptoms in 95.3% for the first rescue dose and 93.3% for the second. Over the 7 days of the study, 82.7%, 82.7% and 86.8% of patients in groups A, B and C respectively were treated with granisetron alone. Headache was the most common side-effect, reported by 9.6% of patients; the majority of headaches were mild. There was no difference between the treatment groups regarding the adverse event rate. We concluded that prophylactic doses of 10 or 40 micrograms kg-1 lead to a safe and satisfactory degree of control of nausea and vomiting induced by high-dose cisplatin. PMID:8180032

  8. A comparison of high-dose and low-dose tranexamic acid antifibrinolytic protocols for primary coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Stephen M McHugh

    2016-01-01

    Full Text Available Background and Aims: Tranexamic acid (TA is used for prophylactic antifibrinolysis in coronary artery bypass surgeries to reduce bleeding. We evaluated the efficacy of two different doses of TA for prophylactic antifibrinolysis in patients undergoing primary coronary artery bypass grafting (CABG surgery in this retrospective cohort study at a tertiary care referral centre. Methods: One-hundred eighty-four patients who underwent primary CABG with cardiopulmonary bypass (CPB via sternotomy between January 2009 and June 2011 were evaluated. Pre-operative patient characteristics, intraoperative data, post-operative bleeding, transfusions, organ dysfunction and 30-day mortality were compared between high-dose TA (30 mg/kg loading dose followed by infusion of 15 mg/kg/h until the end of surgery along with 2 mg/kg priming dose in the bypass circuit and low-dose TA (15 mg/kg loading dose followed by infusion of 6 mg/kg/h until the end of surgery along with 1 mg/kg priming dose in the bypass circuit groups. Univariate comparative analysis of all categorical and continuous variables was performed between the two groups by appropriate statistical tests. Linear and logistic regression analyses were performed to control for the effect of confounding on the outcome variables. Results: Chest tube output, perioperative transfusion of blood products and incidence of re-exploration for bleeding did not differ significantly (P> 0.05 between groups. Post-operative complications and 30-day mortality were comparable between the groups. The presence of cardiogenic shock and increased pre-operative creatinine were found to be associated with increased chest tube output on the post-operative day 2 by multivariable linear regression model. Conclusions: Low-dose TA protocol is as effective as high-dose protocol for antifibrinolysis in patients undergoing primary CABG with CPB.

  9. Split high-dose oral levothyroxine treatment as a successful therapy option in myxedema coma.

    Science.gov (United States)

    Charoensri, Suranut; Sriphrapradang, Chutintorn; Nimitphong, Hataikarn

    2017-10-01

    High-dose intravenous thyroxine (T4) is the preferable treatment for myxedema coma. We describe the clinical course of a 69-year-old man who presented with myxedema coma and received oral levothyroxine (LT4) therapy (1 mg) in a split dose. This suggests split high-dose oral LT4 as a therapeutic option in myxedema coma.

  10. SU-E-T-636: Investigation of Dose Variation in High Dose Radiation Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hyvarinen, M; Leventouri, T; Casey, C; Long, S [Florida Atlantic University, Boca Raton, FL (United States); Pella, S [South Florida Radiation Oncology and Florida Atlantic University, Boca Raton, FL (United States); Dumitru, N [University of Bucharest, Bucharest-magurele, Ilfov (Romania); Herrera, R [Louis Stokes VA Medical Center, Cleveland, OH (United States)

    2014-06-15

    Purpose: The purpose of this study is to revise most of the HDR types of treatments with their applicators and their localization challenges. Since every millimeter of misplacement counts the study will look into the necessity of increasing the immobilization for several types of applicators Methods: The study took over 136 plans generated by the treatment planning system (TPS) looking into the applicator's placement in regard to the organs at risk (OR) and simulated the three possible displacements at the hottest dose point on the critical organ for several accessories to evaluate the variation of the delivered dose at the point due to the displacement. Results: Significant dose variation was obtained for the Contura, Savi, MLM and Prostate applicators. Conclusion: This study data indicates that an improvement of the immobilization devices for HDR is absolutely necessary. Better applicator fixation devices are required too. Developing new immobilization devices for all the applicators is recommended. Florida Atlantic University may provide Travel reimbursements.

  11. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  12. The application of high dose food irradiation in South Africa

    Science.gov (United States)

    de Bruyn, Ingrid Nine

    2000-03-01

    During the 1950s to the end of the 1970s the United States Army developed the basic methodology to produce shelf-stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive "dried cooked" taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The Biogam group at the Atomic Energy Corporation of South Africa is currently producing shelf-stable irradiated meats on a commercial basis. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 45 kGy at a temperature of between -20 and -40°C to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions and can be guaranteed for more than two years as long as the integrity of the packaging is maintained. Safari operators in remote parts of Africa, mountaineers, yachtsmen, canoeists and geological survey teams currently use shelf-stable irradiated meat products produced in South Africa.

  13. The application of high dose food irradiation in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Bruyn, Ingrid Nine de E-mail: debruyni@mweb.co.za

    2000-03-01

    During the 1950s to the end of the 1970s the United States Army developed the basic methodology to produce shelf-stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive 'dried cooked' taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The Biogam group at the Atomic Energy Corporation of South Africa is currently producing shelf-stable irradiated meats on a commercial basis. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 45 kGy at a temperature of between -20 and -40 deg. C to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions and can be guaranteed for more than two years as long as the integrity of the packaging is maintained. Safari operators in remote parts of Africa, mountaineers, yachtsmen, canoeists and geological survey teams currently use shelf-stable irradiated meat products produced in South Africa. (author)

  14. High dose implantations of antimony for buried layer applications

    International Nuclear Information System (INIS)

    Gailliard, J.P.; Dupuy, M.; Garcia, M.; Roussin, J.C.

    1978-01-01

    Electrical and physical properties of high dose implantations of antimony in silicon have been studied for use in buried layer applications. The results have been obtained both on and oriented silicon wafers. Following implantations which lead to amorphization we perform an annealing at 600 0 C for 10 mn in order to recrystallize the layer. The observed electrical properties (μ, R) show that the concentration of electrically active antimony ions is greater than that predicted from the solubility of antimony in silicon. Further annealing (in the range 1050 0 - 1200 0 ) induces: firstly a precipitation of the Sb and secondly a diffusion and dissolution of the precipitates. There is a different evolution of the defects in the and silicon slices. T.E.M. reveals no defects in the wafers after one hour annealing at 1200 0 C, whereas defects and twins remain in wafers. Having obtained the evolution of R with time and temperature it is then determined the implantation and annealing conditions which lead to the low resistivity (R = 10) needed for buried layer applications. Results with very many industrially made devices are discussed

  15. Cation disorder in high-dose, neutron-irradiated spinel

    International Nuclear Information System (INIS)

    Sickafus, K.E.; Larson, A.C.; Yu, N.; Nastasi, M.; Hollenberg, G.W.; Garner, F.A.; Bradt, R.C.

    1994-08-01

    The objective of this effort is to determine whether MgAl 2 O 4 spinel is a suitable ceramic for fusion applications. Here, the crystal structures of MgAl 2 O 4 spinel single crystals irradiated to high neutron fluences [>5·10 26 n/m 2 (E n > 0.1 MeV)] were examined by neutron diffraction. Crystal structure refinement of the highest dose sample indicated that the average scattering strength of the tetrahedral crystal sites decreased by ∼ 20% while increasing by ∼ 8% on octahedral sites. Since the neutron scattering length for Mg is considerably larger than for Al, this results is consistent with site exchange between Mg 2+ ions on tetrahedral sites and Al 3+ ions on octahedral sites. Least-squares refinements also indicated that, in all irradiated samples, at least 35% of Mg 2+ and Al 3+ ions in the crystal experienced disordering replacements. This retained dpa on the cation sublattices is the largest retained damage ever measured in an irradiated spinel material

  16. The application of high dose food irradiation in South Africa

    International Nuclear Information System (INIS)

    Bruyn, Ingrid Nine de

    2000-01-01

    During the 1950s to the end of the 1970s the United States Army developed the basic methodology to produce shelf-stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive 'dried cooked' taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The Biogam group at the Atomic Energy Corporation of South Africa is currently producing shelf-stable irradiated meats on a commercial basis. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 45 kGy at a temperature of between -20 and -40 deg. C to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions and can be guaranteed for more than two years as long as the integrity of the packaging is maintained. Safari operators in remote parts of Africa, mountaineers, yachtsmen, canoeists and geological survey teams currently use shelf-stable irradiated meat products produced in South Africa. (author)

  17. Colon mucosal cells after high-dose fractional irradiation

    International Nuclear Information System (INIS)

    Zorc-Pleskovic, R.; Vraspir-Porenta, O.; Petrovic, D.; Zorc, M.; Pleskovic, L.

    2000-01-01

    The aim of this study was to investigate histological and stereological changes in cryptal enterocytes, mucosal lymphocytes and mast cells 10 days after irradiation. For experimental model, 24 Beagle dogs 1-2 years old were used. Twelve dogs were irradiated 20 days with 32 Gy over the whole pelvis and tail. Another 12 dogs represented a control group. For the detection of apoptosis, the TUNEL technique was used. Histological and stereological analyses were performed using a Wild sampling microscope M 1000. In the irradiated group, volume density (P < 0.01), numerical density (P < 0.05) and average volume of lymphocytes (P < 0.001) were significantly lower than in the nonirradiated group. Numerical areal density of mast cells in the irradiated group was also significantly lower (P < 0.05). Volume density (P < 0.001) and average volume of mast cells (P < 0.001) were significantly higher in the irradiated group. The results of our experiments show that irradiation causes injury and loss of lymphocytes and mast cells in the colon mucosa. Apoptosis was detected in enterocytes and lymphocytes in the irradiated group and in nonirradiated group in equal numbers (2.5 ± 0.3 vs. 2.3 ± 0.3; ns.), suggesting that 10 days after high-dose irradiation, the cell loss is not due to apoptosis. (author)

  18. High dose neutron irradiation damage in beryllium as blanket material

    Energy Technology Data Exchange (ETDEWEB)

    Chakin, V.P. E-mail: fae@niiar.ru; Kazakov, V.A.; Teykovtsev, A.A.; Pimenov, V.V.; Shimansky, G.A.; Ostrovsky, Z.E.; Suslov, D.N.; Latypov, R.N.; Belozerov, S.V.; Kupriyanov, I.B. E-mail: vniinm.400@g23.relkom.ru

    2001-11-01

    The paper presents the investigation results of beryllium products that operated in the SM and BOR-60 reactors up to neutron doses of 2.8x10{sup 22} and 8.0x10{sup 22} cm{sup -2} (E>1 MeV), respectively. The calculated and experimental data are given on helium and tritium accumulation, swelling, micro-hardness and thermal conductivity. The microstructural investigation results of irradiated beryllium are also presented. It is shown that the rate of helium and tritium accumulation in beryllium in the SM and BOR-60 reactors is high enough, which is of interest from the viewpoint of modeling the working conditions of the DEMO fusion reactor. Swelling of beryllium at irradiation temperature of 70-150 deg. C and neutron fluence of 2.8x10{sup 22} cm{sup -2} (E>1 MeV) makes up 0.8-1.5%, at 400 deg. C and fluence of 8x10{sup 22} cm{sup -2} (E>1 MeV)-3.2-5.0%. Irradiation hardening and decrease of thermal conductivity strongly depend on the irradiation temperature and are more significant at reduced temperatures. All results presented in the paper were analyzed with due account of the supposed working parameters of the DEMO fusion reactor blanket.

  19. High dose neutron irradiation damage in beryllium as blanket material

    International Nuclear Information System (INIS)

    Chakin, V.P.; Kazakov, V.A.; Teykovtsev, A.A.; Pimenov, V.V.; Shimansky, G.A.; Ostrovsky, Z.E.; Suslov, D.N.; Latypov, R.N.; Belozerov, S.V.; Kupriyanov, I.B.

    2001-01-01

    The paper presents the investigation results of beryllium products that operated in the SM and BOR-60 reactors up to neutron doses of 2.8x10 22 and 8.0x10 22 cm -2 (E>1 MeV), respectively. The calculated and experimental data are given on helium and tritium accumulation, swelling, micro-hardness and thermal conductivity. The microstructural investigation results of irradiated beryllium are also presented. It is shown that the rate of helium and tritium accumulation in beryllium in the SM and BOR-60 reactors is high enough, which is of interest from the viewpoint of modeling the working conditions of the DEMO fusion reactor. Swelling of beryllium at irradiation temperature of 70-150 deg. C and neutron fluence of 2.8x10 22 cm -2 (E>1 MeV) makes up 0.8-1.5%, at 400 deg. C and fluence of 8x10 22 cm -2 (E>1 MeV)-3.2-5.0%. Irradiation hardening and decrease of thermal conductivity strongly depend on the irradiation temperature and are more significant at reduced temperatures. All results presented in the paper were analyzed with due account of the supposed working parameters of the DEMO fusion reactor blanket

  20. High dose progesterone effects the growth of early chick embryo

    International Nuclear Information System (INIS)

    Iqbal, I.; Qamar, K.

    2014-01-01

    Objective: To find out the effect of high dose progesterone on the development of early chick embryo. Study Design: Lab based randomized controlled trial. Place and Duration of study: This study was carried out in Army Medical College and Post Graduate Institute of Poultry Sciences, Rawalpindi from June 2010 - December 2010. Material and Methods: Forty five specific pathogen free, fertile, eggs of Fyoumi species of chick were selected at zero hour of incubation. They were incubated at 37.5oC and 75% relative humidity for 26 hrs until the embryos reached stage 8 of the development. Then on stage 8 the eggs were divided into three groups consisting of 15 eggs per group. The first group (GI) was incubated without any operation. The second (G2) and third groups (G3) were injected with two and twenty times more than physiologic does of progesterone respectively. After 48 hours of incvbation, all embryos were examined for their development under light microscopy. Results: All the embryos of G1 and G2 showed normal development according to their stage of development, while 4 out of 11 embryos of G3 were under developed and their survival rate was also less. Conclusion: Exogenous progesterone at levels twenty times above its physiologic range effects the development of chick embryos. Further studies are needed to explain the mechanisms of this effect. (author)

  1. Identifying high dose activities in industrial site radiography

    International Nuclear Information System (INIS)

    Heaton, B.

    2000-01-01

    Although the radiation doses received by industrial radiographers in the UK have progressively fallen over the last few years, with most now receiving less than 1 mSv/y, a few still receive, relative to the rest, much higher doses. As a percentage of all radiographers the number stays surprisingly constant from year to year. This paper describes a survey to identify the work causing these doses and suggest possible solutions. The UK Central Index of Dose Information was interrogated to identify the industrial radiography companies having staff (not necessarily the same person) with doses of greater than 5mSv/y in the last three years for which information was available. This was 15 in total. The people on the staff receiving these doses were identified and a questionnaire sent to the companies concerned requesting information about their work. A general questionnaire about the operation of the company was also included. With the agreement of the company these questionnaires were followed up by a visit to the company to interviews a number of the management and the radiographers if available. Both groups were generally very open about their problems and every discussion had a positive outcome. Several areas of work/reasons for the doses have been identified. These are: pipeline radiography, ultra sound radiographers working on nuclear reactors, complex plant work often with several teams in the area, inability to retreat from the wind out equipment due to height or access problems, site pressure to not follow the best practices and a lack of appreciation when a dose was being received or, alternatively, carelessness. Some o these problem areas are very difficult to resolve. However ways in which the Health and Safety can help influence the doses have been identified together with practical suggestions radiographers could adopt. These will be reported. (author)

  2. Study of absorbed dose distribution to high energy electron beams

    International Nuclear Information System (INIS)

    Cecatti, E.R.

    1983-01-01

    The depth absorbed dose distribution by electron beams was studied. The influence of the beam energy, the energy spread, field size and design characteristics of the accelerator was relieved. Three accelerators with different scattering and collimation systems were studied leading todifferent depth dose distributions. A theoretical model was constructed in order to explain the increase in the depth dose in the build-up region with the increase of the energy. The model utilizes a three-dimensional formalism based on the Fermi-Eyges multiple scattering theory, with the introduction of modifications that takes into account the criation of secondary electrons. (Author) [pt

  3. High-dose-rate brachytherapy in uterine cervical carcinoma

    International Nuclear Information System (INIS)

    Patel, Firuza D.; Rai, Bhavana; Mallick, Indranil; Sharma, Suresh C.

    2005-01-01

    Purpose: High-dose-rate (HDR) brachytherapy is in wide use for curative treatment of cervical cancer. The American Brachytherapy Society has recommended that the individual fraction size be <7.5 Gy and the range of fractions should be four to eight; however, many fractionation schedules, varying from institution to institution, are in use. We use 9 Gy/fraction of HDR in two to five fractions in patients with carcinoma of the uterine cervix. We found that our results and toxicity were comparable to those reported in the literature and hereby present our experience with this fractionation schedule. Methods and Materials: A total of 121 patients with Stage I-III carcinoma of the uterine cervix were treated with HDR brachytherapy between 1996 and 2000. The total number of patients analyzed was 113. The median patient age was 53 years, and the histopathologic type was squamous cell carcinoma in 93% of patients. The patients were subdivided into Groups 1 and 2. In Group 1, 18 patients with Stage Ib-IIb disease, tumor size <4 cm, and preserved cervical anatomy underwent simultaneous external beam radiotherapy to the pelvis to a dose of 40 Gy in 20 fractions within 4 weeks with central shielding and HDR brachytherapy of 9 Gy/fraction, given weekly, and interdigitated with external beam radiotherapy. The 95 patients in Group 2, who had Stage IIb-IIIb disease underwent external beam radiotherapy to the pelvis to a dose of 46 Gy in 23 fractions within 4.5 weeks followed by two sessions of HDR intracavitary brachytherapy of 9 Gy each given 1 week apart. The follow-up range was 3-7 years (median, 36.4 months). Late toxicity was graded according to the Radiation Therapy Oncology Group criteria. Results: The 5-year actuarial local control and disease-free survival rate was 74.5% and 62.0%, respectively. The actuarial local control rate at 5 years was 100% for Stage I, 80% for Stage II, and 67.2% for Stage III patients. The 5-year actuarial disease-free survival rate was 88.8% for

  4. Efficacy and Safety of Single and Double Doses of Ivermectin versus 7-Day High Dose Albendazole for Chronic Strongyloidiasis

    Science.gov (United States)

    Suputtamongkol, Yupin; Premasathian, Nalinee; Bhumimuang, Kid; Waywa, Duangdao; Nilganuwong, Surasak; Karuphong, Ekkapun; Anekthananon, Thanomsak; Wanachiwanawin, Darawan; Silpasakorn, Saowaluk

    2011-01-01

    , and double doses of oral ivermectin respectively (P = 0.006) in modified intention to treat analysis. No serious adverse event associated with treatment was found in any of the groups. Conclusion/Significance This study confirms that both a single, and a double dose of oral ivermectin taken two weeks apart, is more effective than a 7-day course of high dose albendazole for patients with chronic infection due to S. stercoralis. Double dose of ivermectin, taken two weeks apart, might be more effective than a single dose in patients with concomitant illness. Trial Registration ClinicalTrials.gov NCT00765024 PMID:21572981

  5. Need for High Radiation Dose (≥70 Gy) in Early Postoperative Irradiation After Radical Prostatectomy: A Single-Institution Analysis of 334 High-Risk, Node-Negative Patients

    International Nuclear Information System (INIS)

    Cozzarini, Cesare; Montorsi, Francesco; Fiorino, Claudio; Alongi, Filippo; Bolognesi, Angelo; Da Pozzo, Luigi Filippo; Guazzoni, Giorgio; Freschi, Massimo; Roscigno, Marco; Scattoni, Vincenzo; Rigatti, Patrizio; Di Muzio, Nadia

    2009-01-01

    Purpose: To determine the clinical benefit of high-dose early adjuvant radiotherapy (EART) in high-risk prostate cancer (hrCaP) patients submitted to radical retropubic prostatectomy plus pelvic lymphadenectomy. Patients and Methods: The clinical outcome of 334 hrCaP (pT3-4 and/or positive resection margins) node-negative patients submitted to radical retropubic prostatectomy plus pelvic lymphadenectomy before 2004 was analyzed according to the EART dose delivered to the prostatic bed, <70.2 Gy (lower dose, median 66.6 Gy, n = 153) or ≥70.2 Gy (median 70.2 Gy, n = 181). Results: The two groups were comparable except for a significant difference in terms of median follow-up (10 vs. 7 years, respectively) owing to the gradual increase of EART doses over time. Nevertheless, median time to prostate-specific antigen (PSA) failure was almost identical, 38 and 36 months, respectively. At univariate analysis, both 5-year biochemical relapse-free survival (bRFS) and disease-free survival (DFS) were significantly higher (83% vs. 71% [p = 0.001] and 94% vs. 88% [p = 0.005], respectively) in the HD group. Multivariate analysis confirmed EART dose ≥70 Gy to be independently related to both bRFS (hazard ratio 2.5, p = 0.04) and DFS (hazard ratio 3.6, p = 0.004). Similar results were obtained after the exclusion of patients receiving any androgen deprivation. After grouping the hormone-naive patients by postoperative PSA level the statistically significant impact of high-dose EART on both 5-year bRFS and DFS was maintained only for those with undetectable values, possibly owing to micrometastatic disease outside the irradiated area in case of detectable postoperative PSA values. Conclusion: This series provides strong support for the use of EART doses ≥70 Gy after radical retropubic prostatectomy in hrCaP patients with undetectable postoperative PSA levels.

  6. Independent verification of the delivered dose in High-Dose Rate (HDR) brachytherapy

    International Nuclear Information System (INIS)

    Portillo, P.; Feld, D.; Kessler, J.

    2009-01-01

    An important aspect of a Quality Assurance program in Clinical Dosimetry is an independent verification of the dosimetric calculation done by the Treatment Planning System for each radiation treatment. The present paper is aimed at creating a spreadsheet for the verification of the dose recorded at a point of an implant with radioactive sources and HDR in gynecological injuries. An 192 Ir source automatic differed loading equipment, GammaMedplus model, Varian Medical System with HDR installed at the Angel H. Roffo Oncology Institute has been used. The planning system implemented for getting the dose distribution is the BraquiVision. The sources coordinates as well as those of the calculation point (Rectum) are entered into the Excel-devised verification program by assuming the existence of a point source in each one of the applicators' positions. Such calculation point has been selected as the rectum is an organ at risk, therefore determining the treatment planning. The dose verification is performed at points standing at a sources distance having at least twice the active length of such sources, so they may be regarded as point sources. Most of the sources used in HDR brachytherapy with 192 Ir have a 5 mm active length for all equipment brands. Consequently, the dose verification distance must be at least of 10 mm. (author)

  7. High doses dosimetry in irradiation process in Argentine

    International Nuclear Information System (INIS)

    Dorda de Cancio, E.M.

    1997-01-01

    These report describes the lung dose dosimetry procedures of the Semi-Industrial Irradiation Plant in Ezeisa Atomic (500,00 Ci of Co 60) and Industrial Picorrad Plant (400,00 Ci of Co 60) using the nitrate dosimeter

  8. High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Skwarchuk, Mark W.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1997-01-01

    Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters are afterloaded with two 192 Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th 12 -L 2 . Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED 50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED 50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED 50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the

  9. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  10. High versus low-dose rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Patankar, Sonali S; Tergas, Ana I; Deutsch, Israel; Burke, William M; Hou, June Y; Ananth, Cande V; Huang, Yongmei; Neugut, Alfred I; Hershman, Dawn L; Wright, Jason D

    2015-03-01

    Brachytherapy plays an important role in the treatment of cervical cancer. While small trials have shown comparable survival outcomes between high (HDR) and low-dose rate (LDR) brachytherapy, little data is available in the US. We examined the utilization of HDR brachytherapy and analyzed the impact of type of brachytherapy on survival for cervical cancer. Women with stages IB2-IVA cervical cancer treated with primary (external beam and brachytherapy) radiotherapy between 2003-2011 and recorded in the National Cancer Database (NCDB) were analyzed. Generalized linear mixed models and Cox proportional hazards regression were used to examine predictors of HDR brachytherapy use and the association between HDR use and survival. A total of 10,564 women including 2681 (25.4%) who received LDR and 7883 (74.6%) that received HDR were identified. Use of HDR increased from 50.2% in 2003 to 83.9% in 2011 (Puse of HDR. While patients in the Northeast were more likely to receive HDR therapy, there were no other clinical or socioeconomic characteristics associated with receipt of HDR. In a multivariable Cox model, survival was similar between the HDR and LDR groups (HR=0.93; 95% CI 0.83-1.03). Similar findings were noted in analyses stratified by stage and histology. Kaplan-Meier analyses demonstrated no difference in survival based on type of brachytherapy for stage IIB (P=0.68), IIIB (P=0.17), or IVA (P=0.16) tumors. The use of HDR therapy has increased rapidly. Overall survival is similar for LDR and HDR brachytherapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Escalation to High Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease

    Science.gov (United States)

    Triplett, Brandon M.; Kuttab, Hani I.; Kang, Guolian; Leung, Wing

    2015-01-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those utilized in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial, 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. There was no observed increase in toxicity until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10–100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, while those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (p=0.008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose escalation strategy remains unclear, as outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. PMID:26278046

  12. Escalation to High-Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease.

    Science.gov (United States)

    Triplett, Brandon M; Kuttab, Hani I; Kang, Guolian; Leung, Wing

    2015-12-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those used in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. Increased toxicity was not observed until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10 and 100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, whereas those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (P = .008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose-escalation strategy remains unclear, because outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. Copyright © 2015 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  13. Patterns of pelvic and acetabular injury among Sudanese patients ...

    African Journals Online (AJOL)

    , S Idris. Abstract. Background: Most of major pelvic fractures result from very high energy trauma and require urgent hospital treatment. However more minor, stable fractures may only require a period of rest and analgesia followed by gradual ...

  14. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    Science.gov (United States)

    Jaccard, Maud; Petersson, Kristoffer; Buchillier, Thierry; Germond, Jean-François; Durán, Maria Teresa; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François O; Bailat, Claude

    2017-02-01

    The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋ m ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋ p ) of up to 8 × 10 6 Gy/s. To do this, we evaluated the overall uncertainties in EBT3 film dosimetry as well as the energy and dose-rate dependence of their response. Our dosimetric system was composed of EBT3 Gafchromic films in combination with a flatbed scanner and was calibrated against an ionization chamber traceable to primary standard. All sources of uncertainties in EBT3 dosimetry were carefully analyzed using irradiations at a clinical radiotherapy linac. Energy dependence was investigated with the same machine by acquiring and comparing calibration curves for three different beam energies (4, 8 and 12 MeV), for doses between 0.25 and 30 Gy. Ḋ m dependence was studied at the clinical linac by changing the pulse repetition frequency (f) of the beam in order to vary Ḋ m between 0.55 and 4.40 Gy/min, while Ḋ p dependence was probed at the prototype machine for Ḋ p ranging from 7 × 10 3 to 8 × 10 6 Gy/s. Ḋ p dependence was first determined by studying the correlation between the dose measured by films and the charge of electrons measured at the exit of the machine by an induction torus. Furthermore, we compared doses from the films to independently calibrated thermo-luminescent dosimeters (TLD) that have been reported as being dose-rate independent up to such high dose-rates. We report that uncertainty below 4% (k = 2) can be achieved in the dose range between 3 and 17 Gy. Results also demonstrated that EBT3 films did not display any detectable energy dependence for electron beam energies between 4 and 12 MeV. No Ḋ m dependence was found either. In addition, we obtained excellent consistency between films and TLDs over the entire Ḋ p

  15. Biological impact of high-dose and dose-rate radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Maliev, V.; Popov, D. [Russian Academy of Science, Vladicaucas (Russian Federation); Jones, J.; Gonda, S. [NASA -Johnson Space Center, Houston (United States); Prasad, K.; Viliam, C.; Haase, G. [Antioxida nt Research Institute, Premier Micronutrient Corporation, Novato (United States); Kirchin, V. [Moscow State Veterinary and Biotechnology Acade my, Moscow (Russian Federation); Rachael, C. [University Space Research Association, Colorado (United States)

    2006-07-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  16. Biological impact of high-dose and dose-rate radiation exposure

    International Nuclear Information System (INIS)

    Maliev, V.; Popov, D.; Jones, J.; Gonda, S.; Prasad, K.; Viliam, C.; Haase, G.; Kirchin, V.; Rachael, C.

    2006-01-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  17. Sexual selection targets cetacean pelvic bones

    Science.gov (United States)

    Dines, J. P.; Otárola-Castillo, E.; Ralph, P.; Alas, J.; Daley, T.; Smith, A. D.; Dean, M. D.

    2014-01-01

    Male genitalia evolve rapidly, probably as a result of sexual selection. Whether this pattern extends to the internal infrastructure that influences genital movements remains unknown. Cetaceans (whales and dolphins) offer a unique opportunity to test this hypothesis: since evolving from land-dwelling ancestors, they lost external hind limbs and evolved a highly reduced pelvis which seems to serve no other function except to anchor muscles that maneuver the penis. Here we create a novel morphometric pipeline to analyze the size and shape evolution of pelvic bones from 130 individuals (29 species) in the context of inferred mating system. We present two main findings: 1) males from species with relatively intense sexual selection (inferred by relative testes size) have evolved relatively large penises and pelvic bones compared to their body size, and 2) pelvic bone shape diverges more quickly in species pairs that have diverged in inferred mating system. Neither pattern was observed in the anterior-most pair of vertebral ribs, which served as a negative control. This study provides evidence that sexual selection can affect internal anatomy that controls male genitalia. These important functions may explain why cetacean pelvic bones have not been lost through evolutionary time. PMID:25186496

  18. Cancer radiotherapy based on femtosecond IR laser-beam filamentation yielding ultra-high dose rates and zero entrance dose.

    Science.gov (United States)

    Meesat, Ridthee; Belmouaddine, Hakim; Allard, Jean-François; Tanguay-Renaud, Catherine; Lemay, Rosalie; Brastaviceanu, Tiberius; Tremblay, Luc; Paquette, Benoit; Wagner, J Richard; Jay-Gerin, Jean-Paul; Lepage, Martin; Huels, Michael A; Houde, Daniel

    2012-09-18

    Since the invention of cancer radiotherapy, its primary goal has been to maximize lethal radiation doses to the tumor volume while keeping the dose to surrounding healthy tissues at zero. Sadly, conventional radiation sources (γ or X rays, electrons) used for decades, including multiple or modulated beams, inevitably deposit the majority of their dose in front or behind the tumor, thus damaging healthy tissue and causing secondary cancers years after treatment. Even the most recent pioneering advances in costly proton or carbon ion therapies can not completely avoid dose buildup in front of the tumor volume. Here we show that this ultimate goal of radiotherapy is yet within our reach: Using intense ultra-short infrared laser pulses we can now deposit a very large energy dose at unprecedented microscopic dose rates (up to 10(11) Gy/s) deep inside an adjustable, well-controlled macroscopic volume, without any dose deposit in front or behind the target volume. Our infrared laser pulses produce high density avalanches of low energy electrons via laser filamentation, a phenomenon that results in a spatial energy density and temporal dose rate that both exceed by orders of magnitude any values previously reported even for the most intense clinical radiotherapy systems. Moreover, we show that (i) the type of final damage and its mechanisms in aqueous media, at the molecular and biomolecular level, is comparable to that of conventional ionizing radiation, and (ii) at the tumor tissue level in an animal cancer model, the laser irradiation method shows clear therapeutic benefits.

  19. Share of erythema dose of solar radiation in high mountains

    International Nuclear Information System (INIS)

    Blumthaler, M.; Ambach, W.

    1987-01-01

    The erythema dose was measured using a Robertson-Berger Sunburn Meter. The spectral sensitivity of the detector is adapted to an erythema action spectrum with the optical center at about 300 nm. The erythema dose is expressed in the biologically relevant Sunburn Units (SU). The Robertson-Berger Sunburn Meter has been recommended by the WMO for global monitoring of solar UV-B erythema dose. UV-A radiation was measured with a UV-radiometer. The spectral sensitivity of the detector has a flat maximum at 345 nm and a half band width of +- 25 nm. Global radiation was measured using a pyranometer. All detectors were placed horizontally and calibrated several times. Readings were taken in intervals of one minute

  20. Pelvic floor physical therapy in urogynecologic disorders.

    Science.gov (United States)

    Kotarinos, Rhonda K

    2003-08-01

    Physical therapists are uniquely qualified to treat pelvic floor dysfunction with conservative management techniques. Techniques associated with incontinence and support functions of the pelvic floor include bladder training and pelvic floor rehabilitation: pelvic floor exercises, biofeedback therapy, and pelvic floor electrical stimulation. Pain associated with mechanical pelvic floor dysfunction can be treated by physical therapists utilizing various manual techniques and modalities. Research documents that conservative management is effective in treating many conditions associated with pelvic floor dysfunction. Research should be conducted to determine if addressing diastasis recti and contracture of the pelvic floor musculature should be a component of the standard physical therapy protocol.

  1. Palliation of advanced pelvic malignant disease with large fraction pelvic radiation and misonidazole: final report of RTOG phase I/II study

    International Nuclear Information System (INIS)

    Spanos, W.J. Jr.; Wasserman, T.; Meoz, R.; Sala, J.; Kong, J.; Stetz, J.

    1987-01-01

    Between October 1979 and June 1982 forty-six patients were entered on a non-randomized Phase I-II protocol for the evaluation of Misonidazole combined with high dose per fraction radiation for the treatment of advanced pelvic malignancies. Pelvic radiation consisted of 1000 cGy in one fraction repeated at 4-week intervals for a total of three treatments. Oral Misonidazole at a dose of 4 gm/m2 was administered 4-6 hr prior to radiation (total dose 12 g/m2). The distribution of histology consisted of 20 gynecologic, 24 bowel, and 2 prostate malignancies. Of the thirty-seven patients completing the three treatments; there were 6 complete responses (14% CR), 10 partial responses (27% PR) 19 minimal or no response (32% NR), and 4 unevaluable. One patient remains NED 5.5 years following radiation. Toxicity directly related to Misonidazole was minimal and consisted primarily of transcient Grade 1, 2 peripheral neuropathy (20% Grade 1, 4% Grade 2) and Grade 2 ototoxicity (4%). Radiation toxicity was significant for late bowel damage. There were 4 (11%) Grade 3 and 7 (19%) Grade 4 gastro-intestinal (GI) toxicities. Kaplan-Meier plot of GI toxicity showed a progressive increase in incidence with time for projected rate of 49% Grade 3, 4 by 12-month. GI toxicity (Grade 3, 4) was also related to tumor response. The complication rate was 80% (4/6) for CR, 30% (3/10) for PR and 26% (5/19) for NR or progression. Because of the GI complication rate, this protocol for palliation of advanced pelvic malignancies has been replaced by a protocol that uses 4 fractions over 2 days (b.i.d.) of 370 cGy per fraction repeated at 3-week intervals for a total of 3 courses

  2. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  3. Impact of lymph node burden on survival of high-risk prostate cancer patients following radical prostatectomy and pelvic lymph node dissection

    Directory of Open Access Journals (Sweden)

    Lisa Moris

    2016-12-01

    Full Text Available Aim: To determine the impact of the extent of lymph node invasion (LNI, on long-term oncological outcomes after radical prostatectomy (RP. Material and methods: In this retrospective study we examined the data of 1249 high-risk, non-metastatic PCa patients treated with RP and pelvic lymph node dissection (PLND between 1989 and 2011 at 8 different tertiary institutions. We fitted univariate and multivariate cox models to assess independent predictors of cancer specific survival (CSS and overall survival (OS. The number of positive LN was dichotomized according to the most informative cut-off predicting CSS. Kaplan-Meier curves assessed CSS and OS rates. Only patients with at least 10 LNs removed at PLND were included. This cut-off was chosen as a surrogate for a well performed PNLD.Results: Mean age was 65 years (median: 66, IQR 60-70. Positive surgical margins were present in 53.7% (n=671. Final Gleason score was 2-6 in 12.7% (n=158, 7 in 52% (n=649 and 8-10 in 35.4% (n=442. The median number of LNs removed during PLND was 15 (IQR 12-17. Of all patients, 1128 (90.3% had 0-3 positive LNs, while 126 (9.7% had ≥4 positive LNs. Patients with 0-3 positive LNs had significantly better CSS outcome at 10-year follow-up compared to patients with ≥4 positive LNs (87% vs. 50%; p < 0.0001. Similar results were obtained for OS, with a 72% vs. 37% (p <0.0001 survival at 10 years for patients with 0-3 vs. ≥4 positive LNs, respectively. At multivariate analysis, final Gleason score 8-10, salvage ADT therapy and ≥4 (vs <4 positive LNs were predictors of worse CSS and OS. Pathological stage pT4 was an additional predictor of worse CSS. Conclusions: Four or more positive LNs, pathological stage pT4 and final Gleason score 8-10 represent independent predictors for worse CSS in patients with high-risk PCa. Primary tumor biology remains a strong driver of tumor progression and patients having ≥4 positive LNs could be considered an enriched patient group in

  4. Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the hypofractionated treatment of high-risk prostate cancer

    International Nuclear Information System (INIS)

    Yuen, Jasper; Rodrigues, George; Trenka, Kristina; Coad, Terry; Yartsev, Slav; D'Souza, David; Lock, Michael; Bauman, Glenn

    2008-01-01

    To compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated high-risk prostate cancer treatment. 3DCRT and dIMRT/Helical Tomotherapy(HT) planning with 10 CT datasets was undertaken to deliver 68 Gy in 25 fractions (prostate) and simultaneously delivering 45 Gy in 25 fractions (pelvic lymph node targets) in a single phase. The paradigms of pelvic vessel targeting (iliac vessels with margin are used to target pelvic nodes) and conformal normal tissue avoidance (treated soft tissues of the pelvis while limiting dose to identified pelvic critical structures) were assessed compared to 3DCRT controls. Both dIMRT/HT and 3DCRT solutions were compared to each other using repeated measures ANOVA and post-hoc paired t-tests. When compared to conformal pelvic vessel targeting, conformal normal tissue avoidance delivered more homogenous PTV delivery (2/2 t-test comparisons; p < 0.001), similar nodal coverage (8/8 t-test comparisons; p = ns), higher and more homogenous pelvic tissue dose (6/6 t-test comparisons; p < 0.03), at the cost of slightly higher critical structure dose (D dose , 1–3 Gy over 5/10 dose points; p < 0.03). The dIMRT/HT approaches were superior to 3DCRT in sparing organs at risk (22/24 t-test comparisons; p < 0.05). dIMRT/HT nodal and pelvic targeting is superior to 3DCRT in dose delivery and critical structure sparing in the setting of hypofractionation for high-risk prostate cancer. The pelvic targeting paradigm is a potential solution to deliver highly conformal pelvic radiation treatment in the setting of nodal location uncertainty in prostate cancer and other pelvic malignancies

  5. Analysis of final products from the liquid alkanes radiolysis at low dose, low temperature and high dose rate

    International Nuclear Information System (INIS)

    Tilquin, B.; Doncker, J. de.

    1991-01-01

    Yields of final products (dimers) from the radiolysis of n-hexane and 2,3-dimethylbutane are studied by capillary chromatographic techniques for trace analysis. Reaction of intermediates with the products, the alkane molecules or impurities, is reduced by using low dose (1 kGy), low temperature (195 K) and high dose rate (LINAC). Temperature is the most important experiment variable; by reducing the temperature, reactions with significant activation energies do not compete with radical-radical termination reactions. Products from LINAC radiolysis provide information about active species (reactive fragment, allylic radical...) which deserve a more detailed examination by direct methods [fr

  6. Dose accumulation of multiple high dose rate prostate brachytherapy treatments in two commercially available image registration systems.

    Science.gov (United States)

    Poder, Joel; Yuen, Johnson; Howie, Andrew; Bece, Andrej; Bucci, Joseph

    2017-11-01

    The purpose of this study was to assess whether deformable image registration (DIR) is required for dose accumulation of multiple high dose rate prostate brachytherapy (HDRPBT) plans treated with the same catheter pattern on two different CT datasets. DIR was applied to 20 HDRPBT patients' planning CT images who received two treatment fractions on sequential days, on two different CT datasets, with the same implant. Quality of DIR in Velocity and MIM image registration systems was assessed by calculating the Dice Similarity Coefficient (DSC) and mean distance to agreement (MDA) for the prostate, urethra and rectum contours. Accumulated doses from each system were then calculated using the same DIR technique and dose volume histogram (DVH) parameters compared to manual addition with no DIR. The average DSC was found to be 0.83 (Velocity) and 0.84 (MIM), 0.80 (Velocity) and 0.80 (MIM), 0.80 (Velocity) and 0.81 (MIM), for the prostate, rectum and urethra contours, respectively. The average difference in calculated DVH parameters between the two systems using dose accumulation was less than 1%, and there was no statistically significant difference found between deformably accumulated doses in the two systems versus manual DVH addition with no DIR. Contour propagation using DIR in velocity and MIM was shown to be at least equivalent to inter-observer contouring variability on CT. The results also indicate that dose accumulation through manual addition of DVH parameters may be sufficient for HDRPBT treatments treated with the same catheter pattern on two different CT datasets. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  7. Prospective Multi-Institutional Study of Definitive Radiotherapy With High-Dose-Rate Intracavitary Brachytherapy in Patients With Nonbulky (<4-cm) Stage I and II Uterine Cervical Cancer (JAROG0401/JROSG04-2)

    Energy Technology Data Exchange (ETDEWEB)

    Toita, Takafumi, E-mail: b983255@med.u-ryukyu.ac.jp [Department of Radiology, Graduate School of Medical Science, University of Ryukyus, Okinawa (Japan); Kato, Shingo [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Niibe, Yuzuru [Department of Radiology, School of Medicine, Kitasato University, Sagamihara (Japan); Ohno, Tatsuya [Gunma University Heavy Ion Medical Center, Maebashi (Japan); Kazumoto, Tomoko [Department of Radiology, Saitama Cancer Center, Saitama (Japan); Kodaira, Takeshi [Department of Radiation Oncology, Aichi Cancer Center, Nagoya (Japan); Kataoka, Masaaki [Department of Radiology, National Shikoku Cancer Center, Ehime (Japan); Shikama, Naoto [Department of Radiation Oncology, Saku Central Hospital, Saku (Japan); Kenjo, Masahiro [Department of Radiation Oncology, Graduate School of Medical Science, Hiroshima University, Hiroshima (Japan); Tokumaru, Sunao [Department of Radiology, Saga University, Saga (Japan); Yamauchi, Chikako [Department of Radiation Oncology, Shiga Medical Center for Adults, Moriyama (Japan); Suzuki, Osamu [Department of Radiation Oncology, Osaka Medical Center for Cancer, Osaka (Japan); Sakurai, Hideyuki [Proton Medical Research Center and Tsukuba University, Tsukuba (Japan); Numasaki, Hodaka; Teshima, Teruki [Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Suita, Osaka (Japan); Oguchi, Masahiko [Department of Radiation Oncology, Cancer Institute Hospital, Tokyo (Japan); Kagami, Yoshikazu [Radiation Oncology Division, National Cancer Center Hospital, Tokyo (Japan); Nakano, Takashi [Department of Radiation Oncology, Gunma University, Graduate School of Medicine, Maebashi (Japan); Hiraoka, Masahiro [Department of Radiation Oncology and Image-applied Therapy, Kyoto University, Graduate School of Medicine, Kyoto (Japan); Mitsuhashi, Norio [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan)

    2012-01-01

    Purpose: To determine the efficacy of a definitive radiotherapy protocol using high-dose-rate intracavitary brachytherapy (HDR-ICBT) with a low cumulative dose schedule in nonbulky early-stage cervical cancer patients, we conducted a prospective multi-institutional study. Methods and Materials: Eligible patients had squamous cell carcinoma of the intact uterine cervix, Federation of Gynecologic Oncology and Obstetrics (FIGO) stages Ib1, IIa, and IIb, tumor size <40 mm in diameter (assessed by T2-weighted magnetic resonance imaging), and no pelvic/para-aortic lymphadenopathy. The treatment protocol consisted of whole-pelvis external beam radiotherapy (EBRT) of 20 Gy/10 fractions, pelvic EBRT with midline block of 30 Gy/15 fractions, and HDR-ICBT of 24 Gy/4 fractions (at point A). The cumulative biologically effective dose (BED) was 62 Gy{sub 10} ({alpha}/{beta} = 10) at point A. The primary endpoint was the 2-year pelvic disease progression-free (PDPF) rate. All patients received a radiotherapy quality assurance review. Results: Between September 2004 and July 2007, 60 eligible patients were enrolled. Thirty-six patients were assessed with FIGO stage Ib1; 12 patients with stage IIa; and 12 patients with stage IIb. Median tumor diameter was 28 mm (range, 6-39 mm). Median overall treatment time was 43 days. Median follow-up was 49 months (range, 7-72 months). Seven patients developed recurrences: 3 patients had pelvic recurrences (2 central, 1 nodal), and 4 patients had distant metastases. The 2-year PDPF was 96% (95% confidence interval [CI], 92%-100%). The 2-year disease-free and overall survival rates were 90% (95% CI, 82%-98%) and 95% (95% CI, 89%-100%), respectively. The 2-year late complication rates (according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer of Grade {>=}1) were 18% (95% CI, 8%-28%) for large intestine/rectum, 4% (95% CI, 0%-8%) for small intestine, and 0% for bladder. No Grade {>=}3 cases were

  8. Phase I/II trial of single-fraction high-dose-rate brachytherapy-boosted hypofractionated intensity-modulated radiation therapy for localized adenocarcinoma of the prostate.

    Science.gov (United States)

    Myers, Michael A; Hagan, Michael P; Todor, Dorin; Gilbert, Lynn; Mukhopadhyay, Nitai; Randolf, Jessica; Heimiller, Jeffrey; Anscher, Mitchell S

    2012-01-01

    A Phase I/II protocol was conducted to examine the toxicity and efficacy of the combination of intensity-modulated radiation therapy (IMRT) with a single-fraction high-dose-rate (HDR) brachytherapy implant. From 2001 through 2006, 26 consecutive patients were treated on the trial. The primary objective was to demonstrate a high rate of completion without experiencing a treatment-limiting toxicity. Eligibility was limited to patients with T stage ≤2b, prostate-specific antigen (PSA) ≤20, and Gleason score ≤7. Treatment began with a single HDR fraction of 6Gy to the entire prostate and 9Gy to the peripheral zone, followed by IMRT optimized to deliver in 28 fractions with a normalized total dose of 70Gy. Patients received 50.4Gy to the pelvic lymph node. The prostate dose (IMRT and HDR) resulted in an average biologic equivalent dose >128Gy (α/β=3). Patients whose pretreatment PSA was ≥10ng/mL, Gleason score 7, or stage ≥T2b received short-term androgen ablation. Median followup was 53 months (9-68 months). There were no biochemical failures by either the American Society of Therapeutic Radiology and Oncology or the Phoenix definitions. The median nadir PSA was 0.32ng/mL. All the 26 patients completed the treatment as prescribed. The rate of Grade 3 late genitourinary toxicity was 3.8% consisting of a urethral stricture. There was no other Grade 3 or 4 genitourinary or gastrointestinal toxicities. Single-fraction HDR-boosted IMRT is a safe effective method of dose escalation for localized prostate cancer. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  9. High-dose-rate intracavitary brachytherapy (HDR-IC) in treatment of cervical carcinoma: 5-year results and implication of increased low-grade rectal complication on initiation of an HDR-IC fractionation scheme

    International Nuclear Information System (INIS)

    Wang Chongjong; Wan Leung, Stephen; Chen Huichun; Sun Limin; Fang Fumin; Changchien Chanchao; Huang Engyen; Wu Jiaming; Chen Chuhnchih

    1997-01-01

    Purpose: To report the treatment results and rectal/bladder complications of cervical carcinoma radically treated with high-dose-rate intracavitary brachytherapy (HDR-IC). The current policy of using three-fraction scheme was examined. Methods and Materials: Between November 1987 and August 1990, 173 patients with cervical carcinoma were treated with curative-intent radiation therapy. Whole pelvic irradiation was administered with 10-MV X ray. Dose to the central cervix was 40-44 Gy in 20-22 fractions, following by pelvic wall boost 6-14 Gy in three to seven fractions with central shielding. 60 Co sources were used for HDR-IC, and 7.2 Gy was given to Point A for three applications, 1-2 weeks apart. Duration of follow-up was 5-7.8 years. Results: Twenty-eight patients (16%) developed central-regional recurrences. Overall 5-year actuarial pelvic control rate was 83%. By stage, 5-year actuarial pelvic control rates were 94%, 87%, and 72% for Stages IB + IIA, IIB + IIIA, and IIIB + IVA, respectively. Thirty-one patients (18%) developed distant metastasis. Overall 5-year actuarial survival rate was 58%. By stage, 5-year actuarial survival rates were 79%, 59%, and 41% for Stages IB + IIA, IIB + IIIA, and IIIB + IVA, respectively. Sixty-six (38%) and 19 patients (11%) developed rectal and bladder complications, respectively. For rectal complication, the overall actuarial rate was 38% at 5 years. By grade, 5-year actuarial rectal complication rates were 24%, 15%, 4%, and 3% for Grades 1-4, respectively. Overall prevalence of rectal complications was 37% and 14% at 2 and 5 years, respectively. Prevalence of low-grade rectal complication (Grades 1 and 2) was dominant at 2 years (30%), but declined to 8% at 5 years. Prevalence of high-grade, severe rectal complication (Grades 3 and 4) remained steady at 2 and 5 years (7% and 6%, respectively). Five-year actuarial bladder complication was 9%. Five-year prevalence of bladder complication was 2%. Conclusion: Using a three

  10. Development of a program for calculation of second dose and securities in brachytherapy high dose rate

    International Nuclear Information System (INIS)

    Esteve Sanchez, S.; Martinez Albaladejo, M.; Garcia Fuentes, J. D.; Bejar Navarro, M. J.; Capuz Suarez, B.; Moris de Pablos, R.; Colmenares Fernandez, R.

    2015-01-01

    We assessed the reliability of the program with 80 patients in the usual points of prescription of each pathology. The average error of the calculation points is less than 0.3% in 95% of cases, finding the major differences in the axes of the applicators (maximum error -0.798%). The program has proved effective previously testing him with erroneous dosimetry. Thanks to the implementation of this program is achieved by the calculation of the dose and part of the process of quality assurance program in a few minutes, highlighting the case of HDR prostate due to having a limited time. Having separate data sheet allows each institution to its protocols modify parameters. (Author)

  11. Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy

    International Nuclear Information System (INIS)

    Marriott, C. J.; Webber, C. E.; Gulenchyn, K. Y.

    2007-01-01

    On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of 131 I. Radiation doses for the designated caregivers were monitored on an hourly basis for 1 week using electronic personal dosemeters. The average penetrating dose was 98±64 μSv. The maximum penetrating dose was 283 μSv. Measured dose rate profiles showed that, on average, one-third of the caregiver dose was received during the journey home from hospital. The mean dose rate profile showed rapid clearance of 131 I with three distinct phases. The corresponding clearance half-times were 131 I contaminating the home. (authors)

  12. Pelvic Muscle Rehabilitation: A Standardized Protocol for Pelvic Floor Dysfunction

    Directory of Open Access Journals (Sweden)

    Rodrigo Pedraza

    2014-01-01

    Full Text Available Introduction. Pelvic floor dysfunction syndromes present with voiding, sexual, and anorectal disturbances, which may be associated with one another, resulting in complex presentation. Thus, an integrated diagnosis and management approach may be required. Pelvic muscle rehabilitation (PMR is a noninvasive modality involving cognitive reeducation, modification, and retraining of the pelvic floor and associated musculature. We describe our standardized PMR protocol for the management of pelvic floor dysfunction syndromes. Pelvic Muscle Rehabilitation Program. The diagnostic assessment includes electromyography and manometry analyzed in 4 phases: (1 initial baseline phase; (2 rapid contraction phase; (3 tonic contraction and endurance phase; and (4 late baseline phase. This evaluation is performed at the onset of every session. PMR management consists of 6 possible therapeutic modalities, employed depending on the diagnostic evaluation: (1 down-training; (2 accessory muscle isolation; (3 discrimination training; (4 muscle strengthening; (5 endurance training; and (6 electrical stimulation. Eight to ten sessions are performed at one-week intervals with integration of home exercises and lifestyle modifications. Conclusions. The PMR protocol offers a standardized approach to diagnose and manage pelvic floor dysfunction syndromes with potential advantages over traditional biofeedback, involving additional interventions and a continuous pelvic floor assessment with management modifications over the clinical course.

  13. The development of radiocaries after high-dose irradiation

    International Nuclear Information System (INIS)

    Willich, N.; Gundacker, K.; Rohloff, R.

    1988-01-01

    39 patients, who were irradiated with doses of 50 to 70 Gy for ENT-tumors over a period of 3.5 months to three years prior to the examination, showed a rapidly progressing caries of the teeth inside the target volume. The teeth outside the target volume developed a caries of less extent. Radiation induced xerostomia, effects of the irradiation of the soft tissues, nutrition habits and hygienics are discussed as causes for the damage of the teeth. (orig.) [de

  14. In vivo study on influence of the heterogeneity of tissues in the dose distribution in high energy X ray therapy

    International Nuclear Information System (INIS)

    Aldred, M.A.

    1987-01-01

    Several authors investigated the effect of the heterogeneity of tissue in the dose distribution in a radiation-therapy. Practically all of them carried out ''in vitro'' measurements using a solid body immersed in a water phantom, in order to simulate the inhomogeneity, such as bone, air cavity, etc. In the present work, ''in vivo'' measurements were performed utilizing thermoluminescent dosimeters, whose appropriateness and convenience are well known. Eight patients at Instituto de Radioterapia Oswaldo Cruz were selected, that were under irradiation treatments in their pelvic region. The ratio between body entry radiation dose and the corresponding exit dose, when compared to the same ratio for a homogeneous phantom, gives the influence of the heterogeneity of the tissue the radiation crosses. The results found in those eight patients have shown that ''in vivo'' measurements present a ratio about 8% smaller that in homogeneous phantom case. (author) [pt

  15. High dose rate 192Ir calibration: Indonesia experiences

    International Nuclear Information System (INIS)

    Nasukha; Tjiptanto, D.; Darmasyah, R.; Kurniawan, B.

    2002-01-01

    Indonesia with a population of more than 200 Million people which spread on about 5000 islands, up to now only has 23 radiotherapy centers and some not active anymore. As mention by Parkin et al that Cervix/Utery and breast cancer are the most estimated numbers of new cases of cancers in women for developing countries, stomach and lung cancers in men. Indonesia as a developing country is likely similar to other developing countries on numbers of new cases of cancers in women. But quite different in men, in Indonesia the most common cancers are nasopharynx and thyroid cancers. The use of lr-192 sources in high dose-rate (HDR) remotely afterloaded brachytherapy treatments have greatly increased in recent years and variety of such sources are commercially available. Nine radiotherapy centers in Indonesia installed Nucletron microSelectron HDR remote afterloader. Based on the data of CiptoMangunkusurno Hospital, Jakarta that the most common cancers are the cervix, breast, nasopharynx and thyroid cancers which of percentage are about 31%, 25 %, 13%, and 6 % respectively. It means that the use of HDR 192 Ir brachytherapy has to be an effective tool in the treatments. Two methods have been studied and applied to calibrate HDR 192 Ir brachytherapy in Indonesia, especially for Nucletron microSelectron HDR 192 lr remote afterloader brachytherapy. Calibration of HDR 192 Ir brachytherapy source has been done by Cavity lonization Chamber and with Well Type lonization Chamber. First, 0.6 cc of NE Farmer type dosimeter that was calibrated to 60 Co and 250 kV of x-rays in air kerma was used in this experiment. Position of measurement (detector and source) at the center of the room and about 1 meter from the floor. Eight variation of distances from 10 cm to 40 cms have been carried out measurement as recommended by IAEA-TECDOC-1079. Correction have been given for scatters, non-uniformity, and attenuation. To solve the problem of scatter correction factor was used Matlab programming

  16. Dramatic response to high-dose icotinib in a lung adenocarcinoma patient after erlotinib failure.

    Science.gov (United States)

    Guan, Yin; Zhao, Hong; Meng, Jing; Yan, Xiang; Jiao, ShunChang

    2014-02-01

    Epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) retreatment is rarely administered for non-small cell lung cancer (NSCLC) patients who did not respond to previous TKI treatment. A high dose of TKI may overcome resistance to the standard dose of TKI and have different effectiveness toward cancer compared with the standard dose of TKI. This manuscript describes a dramatic and durable response to high-dose icotinib in a NSCLC patient who did not respond to a previous standard dose of erlotinib. The treatment extended the life of the patient for one additional year. A higher dose of icotinib deserves further study not only for patients whose therapy failed with the standard dose of TKI but also for newly diagnosed NSCLC patients with a sensitive mutation. Serial mutation testing during disease development is necessary for analysis and evaluation of EGFR TKI treatment. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  18. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  19. The Role of High Dose Interleukin-2 in the Era of Targeted Therapy.

    Science.gov (United States)

    Gills, Jessie; Parker, William P; Pate, Scott; Niu, Sida; Van Veldhuizen, Peter; Mirza, Moben; Holzbeierlein, Jeffery M; Lee, Eugene K

    2017-09-01

    We assessed survival outcomes following high dose interleukin-2 in a contemporary cohort of patients during the era of targeted agents. We retrospectively reviewed the records of patients with metastatic renal cell carcinoma treated with high dose interleukin-2 between July 2007 and September 2014. Clinicopathological data were abstracted and patient response to therapy was based on RECIST (Response Evaluation Criteria In Solid Tumors), version 1.1 criteria. The Kaplan-Meier method was used to estimate progression-free and overall survival in the entire cohort, the response to high dose interleukin-2 in regard to previous targeted agent therapy and the response to the targeted agent in relation to the response to high dose interleukin-2. We identified 92 patients, of whom 87 had documentation of a response to high dose interleukin-2. Median overall survival was 34.4 months from the initiation of high dose interleukin-2 therapy in the entire cohort. Patients who received targeted therapy before high dose interleukin-2 had overall survival (median 34.4 and 30.0 months, p = 0.88) and progression-free survival (median 1.5 and 1.7 months, p = 0.8) similar to those in patients who received no prior therapy, respectively. Additionally, patients with a complete or partial response to high dose interleukin-2 had similar outcomes for subsequent targeted agents compared to patients whose best response was stable or progressive disease (median overall survival 30.1 vs 25.4 months, p = 0.4). Our data demonstrate that patient responses to high dose interleukin-2 and to targeted agents before and after receiving high dose interleukin-2 are independent. As such, carefully selected patients should be offered high dose interleukin-2 for the possibility of a complete and durable response without the fear of limiting the treatment benefit of targeted agents. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Moderate- vs high-dose methadone in the treatment of opioid dependence: a randomized trial.

    Science.gov (United States)

    Strain, E C; Bigelow, G E; Liebson, I A; Stitzer, M L

    1999-03-17

    Methadone hydrochloride treatment is the most common pharmacological intervention for opioid dependence, and recent interest has focused on expanding methadone treatment availability beyond traditional specially licensed clinics. However, despite recommendations regarding effective dosing of methadone, controlled clinical trials of higher-dose methadone have not been conducted. To compare the relative clinical efficacy of moderate- vs high-dose methadone in the treatment of opioid dependence. A 40-week randomized, double-blind clinical trial starting in June 1992 and ending in October 1995. Outpatient substance abuse treatment research clinic at the Johns Hopkins University Bayview Campus, Baltimore, Md. One hundred ninety-two eligible clinic patients. Daily oral methadone hydrochloride in the dose range of 40 to 50 mg (n = 97) or 80 to 100 mg (n = 95), with concurrent