WorldWideScience

Sample records for high dose buprenorphine

  1. High-dose buprenorphine: perioperative precautions and management strategies.

    Science.gov (United States)

    Roberts, D M; Meyer-Witting, M

    2005-02-01

    Buprenorphine has been in clinical use in anaesthesia for several decades. Recently, the high-dose sublingual formulation (Subutex, Reckitt Benckiser, Slough, U.K.) has been increasingly used as maintenance therapy in opioid dependence, as an alternative to methadone and other pharmacological therapies. Buprenorphine has unique pharmacological properties making it well suited for use as a maintenance therapy in opioid dependence. However, these same properties may cause difficulty in the perioperative management of pain. Buprenorphine is a partial opioid agonist, attenuating the effects of supplemental illicit or therapeutic opioid agonists. As a result of its high receptor affinity, supplemental opioids do not readily displace buprenorphine from the opioid receptor in standard doses. High-dose buprenorphine has an extended duration of action that prolongs both of these effects. The perioperative management of patients stabilized on high-dose buprenorphine and undergoing surgery requires consideration of the likely analgesic requirements. Where possible the buprenorphine should be continued. Pain management should focus on maximizing non-opioid analgesia, local anaesthesia and non-pharmacological techniques. Where pain may not be adequately relieved by these methods, the addition of a full opioid agonist such as fentanyl or morphine at appropriate doses should be considered, accompanied by close monitoring in a high dependency unit. In situations where this regimen is unlikely to be effective, preoperative conversion to morphine or methadone may be an option. Where available, liaison with a hospital-based alcohol and drug service should always be considered.

  2. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  3. Buprenorphine Maintenance Subjects Are Hyperalgesic and Have No Antinociceptive Response to a Very High Morphine Dose.

    Science.gov (United States)

    Athanasos, Peter; Ling, Walter; Bochner, Felix; White, Jason M; Somogyi, Andrew A

    2018-03-05

    Acute pain management in opioid-dependent persons is complicated because of tolerance and opioid-induced hyperalgesia. Very high doses of morphine are ineffective in overcoming opioid-induced hyperalgesia and providing antinociception to methadone-maintained patients in an experimental setting. Whether the same occurs in buprenorphine-maintained subjects is unknown. Randomized double-blind placebo-controlled. Subjects were tested on two occasions, at least five days apart, once with intravenous morphine and once with intravenous saline. Subjects were tested at about the time of putative trough plasma buprenorphine concentrations. Ambulatory. Twelve buprenorphine-maintained subjects: once daily sublingual dose (range = 2-22 mg); no dose change for 1.5-12 months. Ten healthy controls. Intravenous morphine bolus and infusions administered over two hours to achieve two separate pseudo-steady-state plasma concentrations one hour apart. Pain tolerance was assessed by application of nociceptive stimuli (cold pressor [seconds] and electrical stimulation [volts]). Ten blood samples were collected for assay of plasma morphine, buprenorphine, and norbuprenorphine concentrations until three hours after the end of the last infusion; pain tolerance and respiration rate were measured to coincide with blood sampling times. Cold pressor responses (seconds): baseline: control 34 ± 6 vs buprenorphine 17 ± 2 (P = 0.009); morphine infusion-end: control 52 ± 11(P = 0.04), buprenorphine 17 ± 2 (P > 0.5); electrical stimulation responses (volts): baseline: control 65 ± 6 vs buprenorphine 53 ± 5 (P = 0.13); infusion-end: control 74 ± 5 (P = 0.007), buprenorphine 53 ± 5 (P > 0.98). Respiratory rate (breaths per minute): baseline: control 17 vs buprenorphine 14 (P = 0.03); infusion-end: control 15 (P = 0.09), buprenorphine 12 (P < 0.01). Infusion-end plasma morphine concentrations (ng/mL): control 23 ± 1

  4. Dexamethasone hepatic induction in rats subsequently treated with high dose buprenorphine does not lead to respiratory depression

    International Nuclear Information System (INIS)

    Hreiche, Raymond; Megarbane, Bruno; Pirnay, Stephane; Borron, Stephen W.; Monier, Claire; Risede, Patricia; Milan, Nathalie; Descatoire, Veronique; Pessayre, Dominique; Baud, Frederic J.

    2006-01-01

    In humans, asphyxic deaths and severe poisonings have been attributed to high-dosage buprenorphine, a maintenance therapy for heroin addiction. However, in rats, intravenous buprenorphine at doses up to 90 mg kg -1 was not associated with significant effects on arterial blood gases. In contrast, norbuprenorphine, the buprenorphine major cytochrome P450 (CYP) 3A-derived metabolite, is a potent respiratory depressant. Thus, our aim was to study the consequences of CYP3A induction on buprenorphine-associated effects on resting ventilation in rats. We investigated the effects on ventilation of 30 mg kg -1 buprenorphine alone or following cytochrome P450 (CYP) 3A induction with dexamethasone, using whole body plethysmography (N = 24) and arterial blood gases (N = 12). Randomized animals in 4 groups received sequential intraperitoneal dosing with: (dexamethasone [days 1-3] + buprenorphine [day 4]), (dexamethasone solvent [days 1-3] + buprenorphine [day 4]), (dexamethasone [days 1-3] + buprenorphine solvent [day 4]), or (dexamethasone solvent [days 1-3] + buprenorphine solvent [day 4]). Buprenorphine alone caused a significant rapid and sustained increase in the inspiratory time (P -1 buprenorphine on rat ventilation. Our results suggest a limited role of drug-mediated CYP3A induction in the occurrence of buprenorphine-attributed respiratory depression in addicts

  5. Switching from high doses of pure u-opioid agonists to transdermal buprenorphine in patients with cancer

    DEFF Research Database (Denmark)

    Lundorff, Lena; Sjøgren, Per; Hansen, Ole Bo

    2013-01-01

    ) brief pain inventory; 3) pain relief and pain intensity; 4) quality of life; and 5) adverse events and symptoms. RESULTS: Eighteen patients receiving 150-516 mg of morphine/day were included. The buprenorphine dose at the end of the study varied between 52.5 and 140 μg/h. No difference in pain before...

  6. Correlations of Maternal Buprenorphine Dose, Buprenorphine, and Metabolite Concentrations in Meconium with Neonatal Outcomes

    Science.gov (United States)

    Kacinko, SL; Jones, HE; Johnson, RE; Choo, RE; Huestis, MA

    2009-01-01

    For the first time, relationships among maternal buprenorphine dose, meconium buprenorphine and metabolite concentrations, and neonatal outcomes are reported. Free and total buprenorphine and norbuprenorphine, nicotine, opiates, cocaine, benzodiazepines, and metabolites were quantified in meconium from 10 infants born to women who had received buprenorphine during pregnancy. Neither cumulative nor total third-trimester maternal buprenorphine dose predicted meconium concentrations or neonatal outcomes. Total buprenorphine meconium concentrations and buprenorphine/norbuprenorphine ratios were significantly related to neonatal abstinence syndrome (NAS ) scores >4. As free buprenorphine concentration and percentage free buprenorphine increased, head circumference decreased. Thrice-weekly urine tests for opiates, cocaine, and benzodiazepines and self-reported smoking data from the mother were compared with data from analysis of the meconium to estimate in utero exposure. Time of last drug use and frequency of use during the third trimester were important factors associated with drug-positive meconium specimens. The results suggest that buprenorphine and metabolite concentrations in the meconium may predict the onset and frequency of NAS. PMID:18701886

  7. Maternal Buprenorphine Dose, Placenta Buprenorphine and Metabolite Concentrations and Neonatal Outcomes

    Science.gov (United States)

    Concheiro, Marta; Jones, Hendreé E.; Johnson, Rolley E.; Choo, Robin; Shakleya, Diaa M.; Huestis, Marilyn A.

    2010-01-01

    Buprenorphine is approved as pharmacotherapy for opioid dependence in non-pregnant patients in multiple countries, and is currently under investigation for pregnant women in the US and Europe. This research evaluates the disposition of buprenorphine, opiates, cocaine, and metabolites in 5 term placentas from a US cohort. Placenta and matched meconium concentrations were compared, and relationships between maternal buprenorphine dose, placenta concentrations, and neonatal outcomes following controlled administration during gestation were investigated. Buprenorphine and/or metabolites were detected in all placenta specimens and were uniformly distributed across this tissue (CV<27.5%, 4 locations), except for buprenorphine in 3 placentas. In 2 of these, buprenorphine was not detected in some locations and, in the 3rd placenta, was totally absent. Median (range) concentrations were buprenorphine 1.6ng/g (not detected to 3.2), norbuprenorphine 14.9ng/g (6.2 to 24.2), buprenorphine-glucuronide 3ng/g (1.3 to 5.0) and norbuprenorphine-glucuronide 14.7ng/g (11.4 to 25.8). Placenta is a potential alternative matrix for detecting in utero buprenorphine exposure, but at lower concentrations (15–70 fold) than in meconium. Statistically significant correlations were observed for mean maternal daily dose from enrollment to delivery and placenta buprenorphine-glucuronide concentration, and for norbuprenorphine-glucuronide concentrations and time to neonatal abstinence syndrome (NAS) onset and duration, and for norbuprenorphine/norbuprenorphine-glucuronide ratio and maximum NAS score, and newborn length. Analysis of buprenorphine and metabolites in this alternative matrix, an abundant waste product available at the time of delivery, may be valuable for prediction of neonatal outcomes for clinicians treating newborns of buprenorphine-exposed women. PMID:20216119

  8. Buprenorphine

    Science.gov (United States)

    ... Updated: 05/31/2016 Medications to Treat OPIOID ADDICTION Methadone Naltrexone Buprenorphine Related SAMHSA Resources Behavioral Health ... Systems Integration Health Disparities Health Financing Health Information Technology HIV, AIDS, and Viral Hepatitis Homelessness and Housing ...

  9. Evaluation of the Pharmacokinetics of Single- and Multiple-dose Buprenorphine Buccal Film in Healthy Volunteers.

    Science.gov (United States)

    Bai, Stephen A; Xiang, Qinfang; Finn, Andrew

    2016-02-01

    Buprenorphine, a partial μ-receptor agonist, is approved for the management of moderate to severe pain, but it has low oral bioavailability. Two open-label studies were performed to determine the pharmacokinetic profile of buprenorphine from buccal film formulations of buprenorphine. Both studies enrolled healthy volunteers, aged 18 to 55 years, who received concurrent oral naltrexone to reduce adverse events (AEs); subjects with a history or evidence of substance abuse or current use of any product affecting cytochrome P450 3A4 activity were excluded. The first study (n = 25) was a 5-period crossover trial with 4 single doses (75 and 300 and 300 and 1200 μg) of 2 formulations (F14 and F24) of buccal buprenorphine (BBUP) and a 300-μg intravenous dose of buprenorphine with a 7-day washout between periods. In the second study, each subject (n = 10) received 6 doses of 4 BBUP strengths (60, 120, 180, and 240 μg BID) in a dose-escalation design. Plasma concentrations of buprenorphine and norbuprenorphine were assayed, and pharmacokinetics were summarized with descriptive statistics and analyzed by using a linear mixed effects model (single-dose study). AEs were recorded. In the single-dose study, the 2 formulations exhibited comparable bioavailability of 46% to 51% that was independent of dose, with a single buprenorphine peak concentration from each BBUP dose occurring at 2.5 to 3 hours. The mean buprenorphine Cmax across the doses ranged from 0.17 ng/mL for the 75-µg dose to 1.43 ng/mL for the 1200-µg dose. AUC0-∞, AUC0-last, and Cmax were proportional to the dose of BBUP administered. Cmax of norbuprenorphine after BBUP administration was approximately one tenth that of buprenorphine Cmax. In the multiple-dose study, steady state was reached within 3 days of BID dosing. There was a linear increase in exposure across the dose range from 60 to 240 μg BID. Treatment-emergent AEs in both studies were consistent with those reported with opiate administration to

  10. Buprenorphine dose induction in non-opioid-tolerant pre-release prisoners.

    Science.gov (United States)

    Vocci, Frank J; Schwartz, Robert P; Wilson, Monique E; Gordon, Michael S; Kinlock, Timothy W; Fitzgerald, Terrence T; O'Grady, Kevin E; Jaffe, Jerome H

    2015-11-01

    In a previously reported randomized controlled trial, formerly opioid-dependent prisoners were more likely to enter community drug abuse treatment when they were inducted in prison onto buprenorphine/naloxone (hereafter called buprenorphine) than when they received counseling without buprenorphine in prison (47.5% vs. 33.7%, p=0.012) (Gordon et al., 2014). In this communication we report on the results of the induction schedule and the adverse event profile seen in pre-release prisoners inducted onto buprenorphine. This paper examines the dose induction procedure, a comparison of the proposed versus actual doses given per week, and side effects reported for 104 adult participants who were randomized to buprenorphine treatment in prison. Self-reported side effects were analyzed using generalized estimated equations to determine changes over time in side effects. Study participants were inducted onto buprenorphine at a rate faster than the induction schedule. Of the 104 (72 males, 32 females) buprenorphine recipients, 64 (37 males, 27 females) remained on medication at release from prison. Nine participants (8.6%) discontinued buprenorphine because of unpleasant opioid side effects. There were no serious adverse events reported during the in-prison phase of the study. Constipation was the most frequent symptom reported (69 percent). Our findings suggest that buprenorphine administered to non-opioid-tolerant adults should be started at a lower, individualized dose than customarily used for adults actively using opioids, and that non-opioid-tolerant pre-release prisoners can be successfully inducted onto therapeutic doses prior to release. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Low-dose naloxone provides an abuse-deterrent effect to buprenorphine

    Directory of Open Access Journals (Sweden)

    Webster LR

    2015-11-01

    Full Text Available Lynn R Webster,1 Michael D Smith,1 Cemal Unal,2 Andrew Finn3 1PRA Health Sciences, Salt Lake City, UT, USA; 2Biometrical Solutions LLC, Raleigh, NC, USA; 3BioDelivery Sciences International, Inc., Raleigh, NC, USA Abstract: In developmental research, plasma buprenorphine concentrations comparable to a 2 mg buprenorphine–naloxone (BN sublingual tablet have been achieved with a 0.75 mg dose of BN buccal film, a small, bioerodible polymer film for application to mucosal membranes. This was a randomized, double-blind, placebo-controlled, single-dose, four-period crossover study in opioid-dependent subjects with chronic pain receiving >100 mg oral morphine equivalents daily who experienced withdrawal following a naloxone challenge dose. The objective of the study was to determine if intravenous (IV naloxone doses of 0.1 and 0.2 mg would produce a withdrawal response when coadministered with a 0.75 mg IV dose of buprenorphine. Fifteen subjects receiving 90–1,260 mg oral morphine equivalents per day enrolled and completed the study. Precipitated withdrawal occurred in 13% (2/15 of placebo-treated subjects and 47% (7/15 of buprenorphine-treated subjects. When combined with the 0.75 mg dose of buprenorphine, a 0.1 mg dose of naloxone increased the incidence of precipitated withdrawal to 60%, and a 0.2 mg dose of naloxone increased the incidence to 73%. By 15 minutes postdose, the mean change in Clinical Opioid Withdrawal Scale (COWS score from predose was 3.0 for placebo, 6.9 for buprenorphine, 9.8 for BN 0.1 mg, and 12.4 for BN 0.2 mg. The mean COWS score with each active treatment was significantly greater than placebo (P<0.001, and the mean COWS score for each of the naloxone-containing treatments was significantly greater than for buprenorphine alone (P<0.001. Naloxone doses as low as 0.1 mg added an abuse-deterrent effect to a 0.75 mg IV dose of buprenorphine. Keywords: opioid dependence, withdrawal symptoms, abuse-deterrent, buprenorphine

  12. Pharmacokinetics of buprenorphine after single-dose subcutaneous administration in red-eared sliders (Trachemys scripta elegans).

    Science.gov (United States)

    Kummrow, Maya S; Tseng, Florina; Hesse, Leah; Court, Michael

    2008-12-01

    Buprenorphine, a mu opioid receptor agonist, is expected to be a suitable analgesic drug for use in reptiles. However, to date, dosage recommendations have been based on anecdotal observations. The aim of this study was to provide baseline pharmacokinetic data in red-eared sliders (Trachemys scripta elegans) targeting a plasma level of 1 ng/ml reported effective for analgesia in humans. Serial blood samples were taken after subcutaneous injection of buprenorphine, and plasma buprenorphine levels were measured by radioimmunoassay. Pharmacokinetic parameters of a lower dose (0.02 mg/kg) injected into the forelimb were compared with a higher dose (0.05 mg/kg) given in the same forelimb as well as a lower dose (0.02 mg/kg) given in the hind limb of the same animals with 2 wk between studies. After administration of 0.05 mg/kg in the front limb, 85% of animals maintained the minimum effective plasma level for 24 hr, while only 43% of animals maintained this level after 0.02 mg/kg. After hind limb injection at 0.02 mg/kg, maximum plasma concentrations and areas under the buprenorphine concentration-time curve were less than 20% and 70%, respectively, of values after forelimb injection, consistent with substantial first pass extraction by the liver. Furthermore, a secondary rise in the buprenorphine level was found after having only a hind limb injection, probably from enterohepatic recirculation of glucuronidated drug. In conclusion, buprenorphine dosages of at least 0.075 mg/kg s.i.d. should be appropriate for evaluation of analgesia efficacy, and front limb administration may be preferable to hind limb administration for optimal drug exposure.

  13. Buprenorphine for managing opioid withdrawal.

    Science.gov (United States)

    Gowing, Linda; Ali, Robert; White, Jason M; Mbewe, Dalitso

    2017-02-21

    Managed withdrawal is a necessary step prior to drug-free treatment or as the endpoint of substitution treatment. To assess the effects of buprenorphine versus tapered doses of methadone, alpha 2 -adrenergic agonists, symptomatic medications or placebo, or different buprenorphine regimens for managing opioid withdrawal, in terms of the intensity of the withdrawal syndrome experienced, duration and completion of treatment, and adverse effects. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, Issue 11, 2016), MEDLINE (1946 to December week 1, 2016), Embase (to 22 December 2016), PsycINFO (1806 to December week 3, 2016), and the Web of Science (to 22 December 2016) and handsearched the reference lists of articles. Randomised controlled trials of interventions using buprenorphine to modify the signs and symptoms of withdrawal in participants who were primarily opioid dependent. Comparison interventions involved reducing doses of methadone, alpha 2 -adrenergic agonists (clonidine or lofexidine), symptomatic medications or placebo, and different buprenorphine-based regimens. We used standard methodological procedures expected by Cochrane. We included 27 studies involving 3048 participants. The main comparators were clonidine or lofexidine (14 studies). Six studies compared buprenorphine versus methadone, and seven compared different rates of buprenorphine dose reduction. We assessed 12 studies as being at high risk of bias in at least one of seven domains of methodological quality. Six of these studies compared buprenorphine with clonidine or lofexidine and two with methadone; the other four studies compared different rates of buprenorphine dose reduction.For the comparison of buprenorphine and methadone in tapered doses, meta-analysis was not possible for the outcomes of intensity of withdrawal or adverse effects. However, information reported by the individual studies was suggestive of buprenorphine and methadone having similar capacity to

  14. Determination of an optimal dose of medetomidine-ketamine-buprenorphine for anaesthesia in the Cape ground squirrel (Xerus inauris

    Directory of Open Access Journals (Sweden)

    K. E. Joubert

    2011-04-01

    Full Text Available The optimal dose of medetomidine-ketamine-buprenorphine was determined in 25 Cape ground squirrels (Xerus inauris undergoing surgical implantation of a temperature logger into the abdominal cavity. At the end of anaesthesia, the squirrels were given atipamezole intramuscularly to reverse the effects of medetomidine. The mean dose of medetomidine was 67.6±9.2 μg/kg, ketamine 13.6±1.9 mg/kg and buprenorphine 0.5±0.06 μg/kg. Induction time was 3.1 ± 1.4 min. This produced surgical anaesthesia for 21± 4.2 min. Atipamezole 232±92 μg/kg produced a rapid recovery. Squirrels were sternally recumbent in 3.5 ± 2.2 min.

  15. Buprenorphine/Naloxone Maintenance Therapy: an Observational Retrospective Report on the Effect of Dose on 18 months Retention in an Office-Based Treatment Program

    Directory of Open Access Journals (Sweden)

    Theodore V Parran

    2017-10-01

    Full Text Available Context and objective: Buprenorphine has been available with few reports of the dose range necessary to adequately maintain patients. We report on the effect of 8 mg/d versus 16 mg/d of buprenorphine on long-term patient retention in office-based opioid maintenance (OBOMT. Design, setting, and participants: Case series, at an urban hospital-based primary care clinic providing OBOMT to 157 opiate-dependent, low socioeconomic status, uninsured, nonhomeless patients. Intervention: The OBOMT program operated by a comprehensive sobriety treatment program experienced State funding cuts. Thus, after 2 years, the program was required by the State funder to decrease the buprenorphine maintenance dose from 16 to 8 mg/d for all new admissions. We report on patient retention before and after dose reduction. Main outcome measures: The primary outcomes of this study were to measure and compare patient retention in the 2 cohorts at each point of treatment transition over the 18 months following OBOMT initiation. Results: No significant differences in patient retention were observed between the 16 and 8 mg/d patient cohorts. Lower dose buprenorphine maintenance (8 mg/d in uninsured patients enrolled in publicly funded long-term OBOMT combined with comprehensive sobriety counseling was as effective as higher dose therapy (16 mg/d in promoting patient retention throughout the study period. This lower dose resulted in a substantial saving to the public funding agency. Conclusions: In an observational retrospective report, retention in treatment of opiate-addicted patients was the same at 8 and 16 mg/d buprenorphine doses after 18 months. These data have implications for public and managed care funding of OBOMT, for the general prescribing of buprenorphine in outpatient care, and may be instructive in the ongoing debate about the relationship between buprenorphine dose.

  16. Transdermal buprenorphine, opioid rotation to sublingual buprenorphine, and the avoidance of precipitated withdrawal: a review of the literature and demonstration in three chronic pain patients treated with butrans.

    Science.gov (United States)

    Kornfeld, Howard; Reetz, Heidi

    2015-01-01

    Buprenorphine is an opioid, used in the United States and abroad for both analgesia and addiction, with unique opioid receptor binding properties. There are several pharmacological features of buprenorphine that make it an emerging option for the long-term treatment of chronic pain-its respiratory suppression ceiling effect, its efficacy in neuropathic pain and hyperalgesic states, and its decreased suppression of the immune and endocrine systems compared with other long-acting opioids. Previous studies have shown that high-dose sublingual buprenorphine is an effective treatment of chronic pain patients not responding to other opioids. Guidelines for the introduction of sublingual buprenorphine, termed buprenorphine induction, include an opioid-free "withdrawal" period of 12-48 hours to avoid an anticipated and accelerated opioid withdrawal, a syndrome described in this article as precipitated withdrawal. The requirement of a period of opioid abstinence before buprenorphine use may present a significant barrier to its adoption for chronic pain. We present a case series of a novel method of sublingual buprenorphine introduction without an induction period, using the recently Food and Drug Administration-approved low-dose transdermal buprenorphine (Butrans; Purdue Pharma L.P.) as a bridge medication. In these cases, buprenorphine was started in opioid-dependent chronic noncancer pain patients who had taken short-acting opioid medications within hours of the initiation of the rotation. This method avoids the painful abstinence period and did not result in precipitated withdrawal or other significant adverse effects.

  17. Serum concentrations of buprenorphine after oral and parenteral administration in male mice

    DEFF Research Database (Denmark)

    Kalliokoski, Otto; Jacobsen, Kirsten R; Hau, Jann

    2011-01-01

    Buprenorphine is the most commonly used drug for peri-operative pain relief in laboratory rodents. The systemic concentrations of buprenorphine were measured in mice following administration intravenously (IV), subcutaneously (SC), orally by gavage and by voluntary ingestion, to determine the post-administration...... serum concentration of buprenorphine. Voluntarily ingested buprenorphine resulted in long-lasting high serum concentrations, as did oral gavage administration (24h serum concentration: 110ngh/mL for both routes of administration). In contrast, buprenorphine administered parenterally remained...... in the circulation for a substantially shorter time (24h serum concentration for IV and SC were 40ngh/mL and 30ngh/mL, respectively). This marked difference was probably due to the higher dose used for oral administration, which is regarded necessary for sufficient analgesic effect, and to the slower absorption...

  18. Pharmacokinetics of a concentrated buprenorphine formulation in red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Gleeson, Molly D; Guzman, David Sanchez-Migallon; Knych, Heather K; Kass, Philip H; Drazenovich, Tracy L; Hawkins, Michelle G

    2018-01-01

    OBJECTIVE To determine the pharmacokinetics and sedative effects of 2 doses of a concentrated buprenorphine formulation after SC administration to red-tailed hawks (Buteo jamaicensis). ANIMALS 6 adult red-tailed hawks. PROCEDURES Concentrated buprenorphine (0.3 mg/kg, SC) was administered to all birds. Blood samples were collected at 10 time points over 24 hours after drug administration to determine plasma buprenorphine concentrations. After a 4-week washout period, the same birds received the same formulation at a higher dose (1.8 mg/kg, SC), and blood samples were collected at 13 time points over 96 hours. Hawks were monitored for adverse effects and assigned agitation-sedation scores at each sample collection time. Plasma buprenorphine concentrations were quantified by liquid chromatography-tandem mass spectrometry. RESULTS Mean time to maximum plasma buprenorphine concentration was 7.2 minutes and 26.1 minutes after administration of the 0.3-mg/kg and 1.8-mg/kg doses, respectively. Plasma buprenorphine concentrations were > 1 ng/mL for mean durations of 24 and 48 hours after low- and high-dose administration, respectively. Mean elimination half-life was 6.23 hours for the low dose and 7.84 hours for the high dose. Mean agitation-sedation scores were higher (indicating some degree of sedation) than the baseline values for 24 hours at both doses. No clinically important adverse effects were observed. CONCLUSIONS AND CLINICAL RELEVANCE Concentrated buprenorphine was rapidly absorbed, and plasma drug concentrations considered to have analgesic effects in other raptor species were maintained for extended periods. Most birds had mild to moderate sedation. Additional studies are needed to evaluate the pharmacodynamics of these doses of concentrated buprenorphine in red-tailed hawks.

  19. A cluster-analytic profiling of heroin-dependent patients based on level, clinical adequacy, and patient-desired adjustment of buprenorphine dosage during buprenorphine-naloxone maintenance treatment in sixteen Spanish centers.

    Science.gov (United States)

    Alcaraz, Saul; González-Saiz, Francisco; Trujols, Joan; Vergara-Moragues, Esperanza; Siñol, Núria; Pérez de Los Cobos, José

    2018-06-01

    Buprenorphine dosage is a crucial factor influencing outcomes of buprenorphine treatment for heroin use disorders. Therefore, the aim of the present study is to identify naturally occurring profiles of heroin-dependent patients regarding individualized management of buprenorphine dosage in clinical practice of buprenorphine-naloxone maintenance treatment. 316 patients receiving buprenorphine-naloxone maintenance treatment were surveyed at 16 Spanish centers during the stabilization phase of this treatment. Patients were grouped using cluster analysis based on three key indicators of buprenorphine dosage management: dose, adequacy according to physician, and adjustment according to patient. The clusters obtained were compared regarding different facets of patient clinical condition. Four clusters were identified and labeled as follows (buprenorphine average dose and percentage of participants in each cluster are given in brackets): "Clinically Adequate and Adjusted to Patient Desired Low Dosage" (2.60 mg/d, 37.05%); "Clinically Adequate and Adjusted to Patient Desired High Dosage" (10.71 mg/d, 29.18%); "Clinically Adequate and Patient Desired Reduction of Low Dosage" (3.38 mg/d, 20.0%); and "Clinically Inadequate and Adjusted to Patient Desired Moderate Dosage" (7.55 mg/d, 13.77%). Compared to patients from the other three clusters, participants in the latter cluster reported more frequent use of heroin and cocaine during last week, lower satisfaction with buprenorphine-naloxone as a medication, higher prevalence of buprenorphine-naloxone adverse effects and poorer psychological adjustment. Our results show notable differences between clusters of heroin-dependent patients regarding buprenorphine dosage management. We also identified a group of patients receiving clinically inadequate buprenorphine dosage, which was related to poorer clinical condition. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Buprenorphine is protective against the depressive effects of norbuprenorphine on ventilation

    International Nuclear Information System (INIS)

    Megarbane, Bruno; Marie, Nicolas; Pirnay, Stephane; Borron, Stephen W.; Gueye, Papa N.; Risede, Patricia; Monier, Claire; Noble, Florence; Baud, Frederic J.

    2006-01-01

    High dose buprenorphine is used as substitution treatment in heroin addiction. However, deaths have been reported in addicts using buprenorphine. The role of norbuprenorphine, an N-dealkyl metabolite of buprenorphine, was hypothesized to explain these fatal cases. We determined the median intravenous lethal dose (LD 5 ) of norbuprenorphine in male Sprague-Dawley rats. The effects of a single intravenous dose of 3 or 9 mg/kg norbuprenorphine alone on arterial blood gases were studied. Finally, the effect of pre- and post-administrations of buprenorphine on norbuprenorphine-induced changes on arterial blood gases were analyzed. Norbuprenorphine's LD 5 was 10 mg kg -1 . Norbuprenorphine 3 mg kg -1 produces the rapid onset of sustained respiratory depression, as demonstrated at 20 min by a maximal significant increase in PaCO 2 (8.4 ± 0.9 versus 5.7 ± 0.1 kPa), decrease in arterial pH (7.25 ± 0.06 versus 7.44 ± 0.01), and hypoxia (8.3 ± 0.6 versus 11.1 ± 0.2 kPa). Buprenorphine not only protected against the effects of 3 mg kg -1 norbuprenorphine in a dose-dependent manner but also reversed the effects when given afterward. Binding experiments suggest a role for mu- and to a lesser extent for delta-opioid receptors in buprenorphine protective effect against norbuprenorphine-induced respiratory depression. In conclusion, our data clearly show that norbuprenorphine alone causes important deleterious effects on ventilation in rats. However, buprenorphine protective effect calls into question the role for norbuprenorphine in respiratory toxicity associated with buprenorphine use

  1. Buprenorphine implants in medical treatment of opioid addiction.

    Science.gov (United States)

    Chavoustie, Steven; Frost, Michael; Snyder, Ole; Owen, Joel; Darwish, Mona; Dammerman, Ryan; Sanjurjo, Victoria

    2017-08-01

    Opioid use disorder is a chronic, relapsing disease that encompasses use of both prescription opioids and heroin and is associated with a high annual rate of overdose deaths. Medical treatment has proven more successful than placebo treatment or psychosocial intervention, and the partial µ-opioid receptor agonist and κ-opioid receptor antagonist buprenorphine is similar in efficacy to methadone while offering lower risk of respiratory depression. However, frequent dosing requirements and potential for misuse and drug diversion contribute to significant complications with treatment adherence for available formulations. Areas covered: This review describes the development of and preliminary data from clinical trials of an implantable buprenorphine formulation. Efficacy and safety data from comparative studies with other administrations of buprenorphine, including tablets and sublingual film, will be described. Key premises of the Risk Evaluation and Mitigation Strategy program for safely administering buprenorphine implants, which all prescribing physicians must complete, are also discussed. Expert commentary: Long-acting implantable drug formulations that offer consistent drug delivery and lower risk of misuse, diversion, or accidental pediatric exposure over traditional formulations represent a promising development for the effective treatment of opioid use disorder.

  2. Comparison of buprenorphine and methadone effects on opiate self-administration in primates.

    Science.gov (United States)

    Mello, N K; Bree, M P; Mendelson, J H

    1983-05-01

    The effects of ascending and descending doses of buprenorphine (0.014-0.789 mg/kg/day) and methadone (0.179-11.86 mg/kg/day) on opiate and food intake were studied in Macaque monkeys over 195 to 245 days. Food (1-g banana pellets) and i.v. drug self-administration (heroin 0.01 or 0.02 mg/kg/injection or Dilaudid 0.02 mg/kg/injection) were maintained on a second-order schedule of reinforcement [FR 4 (VR 16:S)]. Buprenorphine (0.282-0.789 mg/kg/day) produced a significant suppression of opiate self-administration at 2.5 to 7 times the dose shown to be effective in human opiate abusers (P less than .05-.001). Methadone (1.43-11.86 mg/kg/day) did not suppress opiate self-administration in four of five monkeys across a dose range equivalent to 100 to 800 mg/day in man. The distribution of opiate self-administration across drug sessions did not account for the absence of methadone suppression as monkeys took 43% of the total daily opiate injections during the first daily drug session, 2.5 hr after methadone administration. During buprenorphine maintenance, food intake remained stable or increased significantly above base-line levels. Methadone maintenance was associated with significant decrements in food intake in four of five monkeys. Buprenorphine appeared to be significantly more effective in suppressing opiate self-administration than methadone across the dose range studied. Buprenorphine had none of the toxic side effects (seizures, respiratory depression, profound psychomotor retardation) associated with high doses of methadone over 6 to 8 months of daily drug treatment. These data are consistent with clinical studies of buprenorphine effects on heroin self-administration in human opiate addicts.

  3. Incidence of high dosage buprenorphine and methadone shopping behavior in a retrospective cohort of opioid-maintained patients in France.

    Science.gov (United States)

    Delorme, Jessica; Chenaf, Chouki; Kabore, Jean-Luc; Pereira, Bruno; Mulliez, Aurélien; Tremey, Aurore; Brousse, Georges; Zenut, Marie; Laporte, Catherine; Authier, Nicolas

    2016-05-01

    Opioid Substitution Treatment (OST) misuse and diversion have significantly increased worldwide. Obtaining OST prescriptions from multiple prescribers, known as doctor shopping, is a way in which opioids may be diverted. The aim of this study was to assess the incidence of OST (high dosage buprenorphine (HDB) and methadone (MTD)) shopping behavior and identify associated risk factors, and its impact on mortality. A retrospective cohort of patients treated by OST between April 1, 2004 and December 31, 2012 from a sample of the French Health Insurance database was established. Doctor shopping was defined as ≥1 day of overlapping prescriptions written by ≥2 different prescribers and filled in ≥3 different pharmacies. A total of 2043 patients were enrolled, 1450HDB and 593 MTD. The one-year incidence of shopping behavior was 8.4% (95% CI: 7.0-10.1) in HDB group and 0% in MTD group, compared to 0.2% (95% CI: 0.1-0.2) for diuretics. On multivariate analysis, factors associated with HDB shopping behavior were: male gender HR: 1.74 (95% CI: 1.20-2.54); low-income status HR: 2.95 (95% CI: 2.07-4.44); mental health disorders HR: 1.43 (95% CI: 1.06-1.94); concurrent hypnotics use HR: 1.90 (95% CI: 1.39-2.61); concurrent use of weak opioids HR: 1.48 (95% CI: 1.09-1.99) and morphine HR: 1.69 (95% CI: 1.02-2.80). HDB shoppers had a higher, yet non-significant risk of death (HR: 1.56 (95% CI: 0.64-3.81)) than non HDB shoppers. Shopping behavior was only found in high dosage buprenorphine patients and concerned almost one out ten patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. [National and regional market penetration rates of generic's high dosage buprenorphine: its evolution from 2006 to 2008, using reimbursed drug database].

    Science.gov (United States)

    Boczek, Christelle; Frauger, Elisabeth; Micallef, Joëlle; Allaria-Lapierre, Véronique; Reggio, Patrick; Sciortino, Vincent

    2012-01-01

    To assess the national market penetration rate (PR) of generic high-dosage buprenorphine (HDB) in 2008 and its evolution since their marketing (2006), and making a point for each dosage and at regional level. Retrospective study over data using national and regional health reimbursement database over three years (2006-2008). In 2008, the generic HDB's national MPR was 31%. The PR for each dosage were 45% for 0.4 mg, 36% for 2 mg and 19% for 8 mg. The (PR) based on Defined Daily Dose (DDD) was 23% in 2008, 15% in 2007 and 4% in 2006. In 2008, at the regional level, disparities were observed in the adjusted penetration rate from 15% in Île de France to 39% in Champagne Ardennes Lorraine. The national PR of generic HDB has increased. There are differences in MPR in terms of dosage and area. However, this PR is still low (in 2008, 82% of the delivered drugs are generics). © 2012 Société Française de Pharmacologie et de Thérapeutique.

  5. A double blind, within subject comparison of spontaneous opioid withdrawal from buprenorphine versus morphine.

    Science.gov (United States)

    Tompkins, D Andrew; Smith, Michael T; Mintzer, Miriam Z; Campbell, Claudia M; Strain, Eric C

    2014-02-01

    Preliminary evidence suggests that there is minimal withdrawal after the cessation of chronically administered buprenorphine and that opioid withdrawal symptoms are delayed compared with those of other opioids. The present study compared the time course and magnitude of buprenorphine withdrawal with a prototypical μ-opioid agonist, morphine. Healthy, out-of-treatment opioid-dependent residential volunteers (N = 7) were stabilized on either buprenorphine (32 mg/day i.m.) or morphine (120 mg/day i.m.) administered in four divided doses for 9 days. They then underwent an 18-day period of spontaneous withdrawal, during which four double-blind i.m. placebo injections were administered daily. Stabilization and spontaneous withdrawal were assessed for the second opioid using the same time course. Opioid withdrawal measures were collected eight times daily. Morphine withdrawal symptoms were significantly (P withdrawal as measured by mean peak ratings of Clinical Opiate Withdrawal Scale (COWS), Subjective Opiate Withdrawal Scale (SOWS), all subscales of the Profile of Mood States (POMS), sick and pain (0-100) Visual Analog Scales, systolic and diastolic blood pressure, heart rate, respiratory rate, and pupil dilation. Peak ratings on COWS and SOWS occurred on day 2 of morphine withdrawal and were significantly greater than on day 2 of buprenorphine withdrawal. Subjective reports of morphine withdrawal resolved on average by day 7. There was minimal evidence of buprenorphine withdrawal on any measure. In conclusion, spontaneous withdrawal from high-dose buprenorphine appears subjectively and objectively milder compared with that of morphine for at least 18 days after drug cessation.

  6. Co-relationship between sexual dysfunction and high-risk sexual behavior in patients receiving buprenorphine and naltrexone maintenance therapy for opioid dependence.

    Science.gov (United States)

    Ramdurg, Santosh; Ambekar, Atul; Lal, Rakesh

    2015-01-01

    People suffering from substance dependence suffer from various sexual dysfunctions and are at risk for indulging in various high-risk sexual behaviors and thus are vulnerable to acquire various infections such as HIV/AIDS and other sexually transmitted infections. The aim of the study was to evaluate the correlation between sexual dysfunction and high-risk sexual behavior in opioid-dependent men receiving buprenorphine and naltrexone maintenance therapy. Semi-structured questionnaire, brief male sexual functioning inventory and HIV-risk taking behavior scale was administered to a sample of 60 sexually active men, receiving buprenorphine (n = 30) and naltrexone (n = 30) maintenance therapy for opioid dependence. The main outcomes are correlation between severity of sexual dysfunction and HIV-risk taking behavior. The study results showed 83% of the men on buprenorphine and 90% on naltrexone reported at least one of the sexual dysfunction symptoms. There was a negative correlation between sexual dysfunction and HIV-risk taking behavior that suggest severe the dysfunction, higher the risk taking behavior. Significant correlation was present with overall sexual dysfunction and HIV-risk taking behavior (P = 0.028 and in naltrexone receiving group premature ejaculation versus HIV-risk taking behavior however, (P = 0.022, P sexual dysfunctions and HIV-risk taking behavior, which has clinical implication. Future research should explore this further using biochemical analyses.

  7. Safety and tolerability of the switch from buprenorphine to buprenorphine/naloxone in an Italian addiction treatment centre.

    Science.gov (United States)

    Stimolo, Clementina; Favero, Valentina Del; Zecchinato, Giancarlo; Buson, Roberto; Cusin, Davide; Pellachin, Patrizia; Simonetto, Pamela

    2010-01-01

    Abuse and misuse of pharmacological therapies represent major challenges in the healthcare system, particularly in patients receiving long-acting opioid drugs for the treatment of heroin or opioid addiction. The partial mu-opioid receptor agonist buprenorphine is used to treat opioid dependence, but diversion and misuse may occur. The sublingual combination formulation of buprenorphine and the opioid receptor antagonist naloxone (buprenorphine/naxolone) is associated with a reduced abuse potential, and has been shown to have promising efficacy for the treatment of opioid dependence. This observational study assessed the safety and efficacy of sublingual buprenorphine/naloxone combination therapy in patients with opioid dependence after therapeutic switch from buprenorphine monotherapy. A total of 94 patients being treated with buprenorphine monotherapy (average dose 8 mg/day; mean duration of therapy 840 days) were switched to buprenorphine/naloxone combination therapy. Patients were asked to rate their level of satisfaction with buprenorphine/naloxone combination treatment with respect to the management of withdrawal symptoms, and urinary toxicology tests were carried out before and 14 days after switching to combination therapy. Within 3 months, 75/94 patients (80%) previously treated with buprenorphine monotherapy had switched to sublingual buprenorphine/naloxone combination treatment (average dose buprenorphine 8 mg). Among patients receiving combination treatment for >3 months, 83% were receiving medication either weekly or fortnightly, based on the results of toxicological testing. A reduction in positive urinary toxicology tests was observed in patients within two weeks after being switched to combination treatment (before switch: 28, 9 and 2 positive tests for heroin, cocaine and heroin + cocaine, respectively vs 11, 3 and 1 after switch) and a total of 64 patients of the 75 who switched to combination therapy (85%) were satisfied with the management of

  8. Assessment of buprenorphine, carprofen, and their combination for postoperative analgesia in olive baboons (Papio anubis).

    Science.gov (United States)

    Allison, Sarah O; Halliday, Lisa C; French, Jeffrey A; Novikov, Dmitri D; Fortman, Jeffrey D

    2007-05-01

    This study compared the efficacy of buprenorphine, carprofen, and a combination of the 2 analgesics in female baboons. Physiologic and behavioral parameters were assessed at baseline and postoperatively for 6 d by use of continuous noninvasive physiologic monitoring and twice-daily videotaping. Prior to surgery, all animals received a pre-emptive dose of either 0.01 mg/kg buprenorphine intramuscularly, 2.2 mg/kg carprofen intramuscularly, or a combination of 0.01 mg/kg buprenorphine and 2.2 mg/kg carprofen intramuscularly. All animals in the carprofen (n = 4) and buprenorphine+carprofen (n = 4) treatment groups appeared to have sufficient analgesia. Three of 4 animals in the buprenorphine group had adequate analgesia. The fourth animal had an elevated heart rate and spent less time standing during the postoperative period. In this study, the use of carprofen or a combination of carprofen plus buprenorphine provided more reliable postoperative analgesia than buprenorphine alone.

  9. Benefits of using intrathecal buprenorphine.

    Science.gov (United States)

    Rabiee, Seyed Mozaffar; Alijanpour, Ebrahim; Jabbari, Ali; Rostami, Sara

    2014-01-01

    General anesthesia draws attention to the most commonly used modalities for post cesarean delivery pain relief in systemic administration of opioids, while the administration of small dose of intrathecal opioid during spinal anesthesia can be a possible alternative. The aim of this study was to evaluate the effects of buprenorphine on cesarean section prescribed intrathecally. This double blind randomized clinical trial study was conducted in patients for cesarean section under spinal anesthesia. The patients were randomly divided into case and control groups. Case group (208 patients) received 65-70 mg of 5% lidocaine plus 0.2 ml of buprenorphine while the same amount of 5% lidocaine diluted with 0.2 ml of normal saline was given to 234 cases in the control group. Hemodynamic changes and neonatal APGAR scores (Appearance, Pulse, Grimace, Activity, Respiration) were recorded. Pain score was recorded according to the visual analog scale. This study was registered in the Iranian Registry of clinical Trials; IRCT2013022112552N1. The mean age of case and control groups was 24.4±5.38 and 26.84±5.42 years, respectively. Systolic blood pressure was not significantly different until the 45th minute but diastolic blood pressure showed a significant difference at the 15th and the 60th minutes (P<0.001). Heart rate changes were significantly different between cases and controls at the initial 5th, 15th and after 60th minutes (P<0.001). Pain-free period was significantly different between two groups (1.25 h versus 18.73 h) (P<0.001). The results show that prescription of intratechal buprenorphine prolongs the duration of analgesia without any significant considerable side effects.

  10. Co-relationship between sexual dysfunction and high-risk sexual behavior in patients receiving buprenorphine and naltrexone maintenance therapy for opioid dependence

    Directory of Open Access Journals (Sweden)

    Santosh Ramdurg

    2015-01-01

    Full Text Available Introduction: People suffering from substance dependence suffer from various sexual dysfunctions and are at risk for indulging in various high-risk sexual behaviors and thus are vulnerable to acquire various infections such as HIV/AIDS and other sexually transmitted infections. AIM: The aim of the study was to evaluate the correlation between sexual dysfunction and high-risk sexual behavior in opioid-dependent men receiving buprenorphine and naltrexone maintenance therapy. Materials and Methods: Semi-structured questionnaire, brief male sexual functioning inventory and HIV-risk taking behavior scale was administered to a sample of 60 sexually active men, receiving buprenorphine (n = 30 and naltrexone (n = 30 maintenance therapy for opioid dependence. Results: The main outcomes are correlation between severity of sexual dysfunction and HIV-risk taking behavior. The study results showed 83% of the men on buprenorphine and 90% on naltrexone reported at least one of the sexual dysfunction symptoms. There was a negative correlation between sexual dysfunction and HIV-risk taking behavior that suggest severe the dysfunction, higher the risk taking behavior. Significant correlation was present with overall sexual dysfunction and HIV-risk taking behavior (P = 0.028 and in naltrexone receiving group premature ejaculation versus HIV-risk taking behavior however, (P = 0.022, P < 0.05 there were no significant differences among both the groups except above findings. Conclusion: Conclusion was treatment is associated with sexual dysfunctions and HIV-risk taking behavior, which has clinical implication. Future research should explore this further using biochemical analyses.

  11. Buprenorphine in the treatment of opioid addiction: opportunities, challenges and strategies.

    Science.gov (United States)

    Li, Xiaofan; Shorter, Daryl; Kosten, Thomas R

    2014-10-01

    Buprenorphine follows the success of methadone as another milestone in the history of treatment for opioid addiction. Buprenorphine can be used in an office-based setting where it is clearly effective, highly accepted by patients and has a favorable safety profile and less abuse potential. However, the adoption of buprenorphine treatment has been slow in the USA. This article first reviews the history of medication-assisted opioid addiction treatment and the current epidemic opioid addiction, followed by a review of the efficacy, pharmacology and clinical prescription of buprenorphine in office-based care. We then explore the possible barriers in using buprenorphine and the ways to overcome these barriers, including new formulations, educational programs and policy regulations that strike a balance between accessibility and reducing diversion. Buprenorphine can align addiction treatment with treatments for other chronic medical illnesses. However, preventing diversion will require graduate and continuing medical education and integrated care models for delivery of buprenorphine to those in need.

  12. Predictive factors for relapse in patients on buprenorphine maintenance.

    Science.gov (United States)

    Ferri, Michael; Finlayson, Alistair J Reid; Wang, Li; Martin, Peter R

    2014-01-01

    Despite the dramatic increase in the use of buprenorphine for the treatment of opioid dependence, clinical outcomes of this treatment approach continue to need evaluation. This study examines factors associated with relapse and retention during buprenorphine treatment in a sample of opioid dependent outpatients. In a retrospective chart review of 62 patients with opioid dependence, relapse was determined by self-report, urine toxicology screens, and by checking the state controlled substance monitoring database. Data was analyzed using two-way tests of association and logistic regression. Patients with comorbid anxiety disorders, active benzodiazepine use (contrary to clinic policy), or active alcohol abuse, were significantly more likely to relapse. Patients who relapsed were also more likely to be on a higher buprenorphine maintenance dose. This study identifies relapse risk factors during buprenorphine treatment for opioid dependence. Future research is needed to determine whether modifying these factors may lead to improved treatment outcomes. © American Academy of Addiction Psychiatry.

  13. Use of 0.5% bupivacaine with buprenorphine in minor oral surgical procedures.

    Science.gov (United States)

    Nagpal, Varun; Kaur, Tejinder; Kapila, Sarika; Bhullar, Ramandeep Singh; Dhawan, Amit; Kaur, Yashmeet

    2017-01-01

    Minor oral surgical procedures are the most commonly performed procedures by oral and maxillofacial surgeons. Performance of painless surgical procedure is highly appreciated by the patients and is possible through the use of local anesthesia, conscious sedation or general anesthesia. Postoperative pain can also be controlled by the use of opioids, as opioid receptors exist in the peripheral nervous system and offers the possibility of providing postoperative analgesia in the surgical patient. The present study compares the efficacy of 0.5% bupivacaine versus 0.5% bupivacaine with 0.3 mg buprenorphine in minor oral surgical procedures. The present study was conducted in 50 patients who required minor oral surgical procedures under local anesthesia. Two types of local anesthetic solutions were used- 0.5% bupivacaine with 1:200000 epinephrine in group I and a mixture of 39 ml of 0.5% bupivacaine with epinephrine 1:200000 and 1 ml of 300 μg buprenorphine (3 μg/kg)in group II. Intraoperative and postoperative evaluation was carried out for both the anesthetic solutions. The mean duration of postoperative analgesia in bupivacaine group (508.92 ± 63.30 minutes) was quite less than the buprenorphine combination group (1840.84 ± 819.51 minutes). The mean dose of postoperative analgesic medication in bupivacaine group (1.64 ± 0.99 tablets) was higher than buprenorphine combination group (0.80 ± 1.08 tablets). There was no significant difference between the two groups regarding the onset of action of the anesthetic effect and duration of anesthesia. Buprenorphine can be used in combination with bupivacaine for patients undergoing minor oral surgical procedures to provide postoperative analgesia for a longer duration.

  14. Assessment of the sedative effects of buprenorphine administered with 20 microg/kg detomidine in horses.

    Science.gov (United States)

    Love, E J; Taylor, P M; Murrell, J; Whay, H R; Waterman-Pearson, A E

    2011-04-16

    The aim of this randomised, observer-blinded, crossover study was to compare the effects of four treatments, administered intravenously to six horses: saline and saline; 10 µg/kg detomidine and 7.5 µg/kg buprenorphine; 20 µg/kg detomidine and 7.5 µg/kg buprenorphine; and 20 µg/kg detomidine and 10 µg/kg buprenorphine. Sedation was subjectively assessed and recorded on a visual analogue scale. Peak sedation and duration of sedation were investigated using a univariate general linear model with post-hoc Tukey tests (Pdetomidine from 10 to 20 µg/kg increased the degree of sedation when administered with the same dose of buprenorphine (7.5 µg/kg). When administered with 20 µg/kg detomidine, increasing the dose of buprenorphine from 7.5 to 10 µg/kg did not influence the degree of sedation achieved.

  15. [Modification of the analgetic effects (buprenorphine, pentazocine, pethidine) on respiration and haemodynamics by epidural, halothane- or neuroleptanaesthesia (author's transl)].

    Science.gov (United States)

    Wüst, H J; Moritz, K G; Sandmann, W; Richter, O

    1980-04-01

    In 38 patients buprenorphine, meperidine and pentazocine were given in a single dose for postoperative pain relief 20 hours after the end of anaesthesia. Measuring the parameters of the high- and low-pressure system as well as the metabolism the authors found that the effects of these analgetic medicaments, intravenously injected were significantly influenced by fentanyl, halothane or diazepam, given under the course of operation. Especially buprenorphine, injected after epidural anaesthesia in combination with diazepam sedation, proved to have a rather negative effect, because it caused a strong depression of respiration and circulation. On the other hand buprenorphine had, given after neuroleptanaesthesia, a neutralizing - and pentazocine and pethidine in combination with neuroleptanaesthesia a stimulating influence on the circulation. After halothane-anaesthesia the effect of the analegtics on the cardiovascular system was, when buprenorphine was given, depressing and when pentazocine was given indifferent. Similar reactions, but more pronounced, could be seen in the epidural group. With certain reservations, caused by the preliminary character of this study, the following conclusions can be drawn for the anaesthetic practice: 1 Choosing analgetic drugs for postoperative pain relief, the anaesthesist has to be aware of the interactions, possibly resulting from the medicaments, given during anaesthesia. 2. The number of medicaments, given during anaesthesia, should be kept small, considering the eventual interactions and the unintentional secondary effects.

  16. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  17. Hospital morphine preparation for abstinence syndrome in newborns exposed to buprenorphine or methadone.

    Science.gov (United States)

    Colombini, Nathalie; Elias, Riad; Busuttil, Muriel; Dubuc, Myriam; Einaudi, Marie-Ange; Bues-Charbit, Martine

    2008-06-01

    This study was undertaken to evaluate the adequacy of a hospital formulated oral morphine preparation for management of neonatal abstinence syndrome (NAS) and to compare clinical features in infants exposed to methadone or buprenorphine in utero. Between October 1998 and October 2004 all infants born to mothers treated with buprenorphine or methadone during pregnancy were enrolled into this prospective study. Morphine hydrochloride solution (0.2 mg/ml) was prepared without preservatives under a flow laminar air box (class 100). Morphine solution: quantitative and qualitative HPLC analysis and microbiological study at regular intervals during storage at 4 degrees C for 6 months. Maternal characteristics: age, opiate dose during pregnancy. Neonatal characteristics: gestational age at delivery, birth weight, Lipsitz scores. Morphine dose: daily morphine dose, maximum morphine dose, duration of NAS, and duration of treatment required to achieve stable Lipsitz scores below 4. Kruskal-Wallis test for comparison of median values. Microbiological and HPLC analysis showed that the morphine preparation remained stable for 6 months at 4 degrees C. Nine methadone-exposed infants and 13 buprenorphine-exposed infants were included in the study. All infants presented NAS requiring treatment with the morphine solution. Lipsitz scores at birth were significantly different in the methadone and buprenorphine groups (P methadone group required significantly higher doses of morphine preparation than the buprenorphine group during the first 38 days of treatment (P methadone-exposed infants (range 6-24 h) and within 48 h after birth in buprenorphine-exposed infants (range 24-168 h). Due to the possibility of delayed onset of NAS up to 7 days, infants born to mothers treated with buprenorphine should be kept in the hospital for an appropriate surveillance period. Treatment time was significantly longer (45 vs. 28 days) and the mean morphine doses were higher (1.7 fold) in methadone

  18. Retention on buprenorphine is associated with high levels of maximal viral suppression among HIV-infected opioid dependent released prisoners.

    Directory of Open Access Journals (Sweden)

    Sandra A Springer

    Full Text Available HIV-infected prisoners lose viral suppression within the 12 weeks after release to the community. This prospective study evaluates the use of buprenorphine/naloxone (BPN/NLX as a method to reduce relapse to opioid use and sustain viral suppression among released HIV-infected prisoners meeting criteria for opioid dependence (OD.From 2005-2010, 94 subjects meeting DSM-IV criteria for OD were recruited from a 24-week prospective trial of directly administered antiretroviral therapy (DAART for released HIV-infected prisoners; 50 (53% selected BPN/NLX and were eligible to receive it for 6 months; the remaining 44 (47% selected no BPN/NLX therapy. Maximum viral suppression (MVS, defined as HIV-1 RNA<50 copies/mL, was compared for the BPN/NLX and non-BPN/NLX (N = 44 groups.The two groups were similar, except the BPN/NLX group was significantly more likely to be Hispanic (56.0% v 20.4%, from Hartford (74.4% v 47.7% and have higher mean global health quality of life indicator scores (54.18 v 51.40. MVS after 24 weeks of being released was statistically correlated with 24-week retention on BPN/NLX [AOR = 5.37 (1.15, 25.1], having MVS at the time of prison-release [AOR = 10.5 (3.21, 34.1] and negatively with being Black [AOR = 0.13 (0.03, 0.68]. Receiving DAART or methadone did not correlate with MVS.In recognition that OD is a chronic relapsing disease, strategies that initiate and retain HIV-infected prisoners with OD on BPN/NLX is an important strategy for improving HIV treatment outcomes as a community transition strategy.

  19. Buprenorphine Maintenance for Opioid Dependence in Public Sector Healthcare: Benefits and Barriers.

    Science.gov (United States)

    Duncan, Laura G; Mendoza, Sonia; Hansen, Helena

    Since its U.S. FDA approval in 2002, buprenorphine has been available for maintenance treatment of opiate dependence in primary care physicians' offices. Though buprenorphine was intended to facilitate access to treatment, disparities in utilization have emerged; while buprenorphine treatment is widely used in private care setting, public healthcare integration of buprenorphine lags behind. Through a review of the literature, we found that U.S. disparities are partly due to a shortage of certified prescribers, concern of patient diversion, as well as economic and institutional barriers. Disparity of buprenorphine treatment dissemination is concerning since buprenorphine treatment has specific characteristics that are especially suited for low-income patient population in public sector healthcare such as flexible dosing schedules, ease of concurrently treating co-morbidities such as HIV and hepatitis C, positive patient attitudes towards treatment, and the potential of reducing addiction treatment stigma. As the gap between buprenorphine treatment in public sector settings and private sector settings persists in the U.S., current research suggests ways to facilitate its dissemination.

  20. Preference for brand-name buprenorphine is related to severity of addiction among outpatients in opioid maintenance treatment.

    Science.gov (United States)

    Binder, Philippe; Messaadi, Nassir; Perault-Pochat, Marie-Christine; Gagey, Stéphanie; Brabant, Yann; Ingrand, Pierre

    2016-01-01

    As a form of opioid maintenance treatment, high-dose buprenorphine is increasingly being used in the United States. On the French market since 1996, it is the most commonly prescribed and frequently employed opioid maintenance treatment. For unknown reasons, the brand-name form is used far more often than the generic form (76-24%). The objective was to show that the patients' levels of addiction were differentiated according to the form of buprenorphine currently being used and to their previous experience of a different form. An observational study in 9 sites throughout France used self-assessment questionnaires filled out in retail pharmacies by all patients to whom their prescribed buprenorphine treatment was being delivered. The 151 canvassed pharmacies solicited 879 patients, of whom 724 completed the questionnaires. Participants were statistically similar to non-participants. The patients using the brand-name form subsequent to experience with the generic form exhibited a more elevated addiction severity index and a higher dosage than brand-name form users with no experience of a different form. Compared to generic users, their doses were higher, their was addiction more severe, and their alcohol consumption was more excessive; they were also more likely to make daily use of psychotropic substances. However, the level of misuse or illicit consumption was similar between these groups. Preferring the brand-name buprenorphine form to the generic form is associated with a higher level of severe addiction, a more frequent need for daily psychotropics, and excessive drinking; but the study was unable to show a causal link.

  1. Morphine- and buprenorphine-induced analgesia and antihyperalgesia in a human inflammatory pain model: a double-blind, randomized, placebo-controlled, five-arm crossover study

    Directory of Open Access Journals (Sweden)

    Ravn P

    2013-01-01

    /heat injury relative to placebo for low-dose morphine was 0.01 (interquartile range: −6.2; 9.9, 0.00 (−2.4; 2.1 for high-dose morphine, 0.03 (−1.8; 2.1 for low-dose buprenorphine, and 0.00 (−3.2; 1.1 for high-dose buprenorphine (P > 0.466. There were no significant differences in opioid responses between high and low pain-sensitive subjects (P > 0.286. High-dose buprenorphine, compared to placebo, was associated with a significantly enhanced action of the descending inhibitory pain control system (P = 0.004.Conclusion: The present study, using multimodal testing technique, could not demonstrate any significant differences between morphine and buprenorphine in the profiles of antihyperalgesia and analgesia. Only high-dose buprenorphine was associated with a significant effect on the descending inhibitory pain control system.Keywords: analgesia, antihyperalgesia, experimental pain, opioid, pain sensitivity, randomized trial

  2. Poly-substance use and antisocial personality traits at admission predict cumulative retention in a buprenorphine programme with mandatory work and high compliance profile.

    Science.gov (United States)

    Öhlin, Leif; Hesse, Morten; Fridell, Mats; Tätting, Per

    2011-05-12

    Continuous abstinence and retention in treatment for alcohol and drug use disorders are central challenges for the treatment providers. The literature has failed to show consistent, strong predictors of retention. Predictors and treatment structure may differ across treatment modalities. In this study the structure was reinforced by the addition of supervised urine samples three times a week and mandatory daily work/structured education activities as a prerequisite of inclusion in the program. Of 128 patients consecutively admitted to buprenorphine maintenance treatment five patients dropped out within the first week. Of the remaining 123 demographic data and psychiatric assessment were used to predict involuntary discharge from treatment and corresponding cumulative abstinence probability. All subjects were administered the Structured Clinical Interview for DSM-IV-TR, and the Symptom Checklist 90 (SCL-90), the Alcohol Use Disorder Identification Test (AUDIT), the Swedish universities Scales of Personality (SSP) and the Sense of Coherence Scale (SOC), all self-report measures. Some measures were repeated every third month in addition to interviews. Of 123 patients admitted, 86 (70%) remained in treatment after six months and 61 (50%) remained in treatment after 12 months. Of those discharged involuntarily, 34/62 individuals were readmitted after a suspension period of three months. Younger age at intake, poly-substance abuse at intake (number of drugs in urine), and number of conduct disorder criteria on the SCID Screen were independently associated with an increased risk of involuntary discharge. There were no significant differences between dropouts and completers on SCL-90, SSP, SOC or AUDIT. Of the patients admitted to the programme 50% stayed for the first 12 months with continuous abstinence and daily work. Poly-substance use before intake into treatment, high levels of conduct disorder on SCID screen and younger age at intake had a negative impact on

  3. Poly-substance use and antisocial personality traits at admission predict cumulative retention in a buprenorphine programme with mandatory work and high compliance profile

    Directory of Open Access Journals (Sweden)

    Fridell Mats

    2011-05-01

    Full Text Available Abstract Background Continuous abstinence and retention in treatment for alcohol and drug use disorders are central challenges for the treatment providers. The literature has failed to show consistent, strong predictors of retention. Predictors and treatment structure may differ across treatment modalities. In this study the structure was reinforced by the addition of supervised urine samples three times a week and mandatory daily work/structured education activities as a prerequisite of inclusion in the program. Methods Of 128 patients consecutively admitted to buprenorphine maintenance treatment five patients dropped out within the first week. Of the remaining 123 demographic data and psychiatric assessment were used to predict involuntary discharge from treatment and corresponding cumulative abstinence probability. All subjects were administered the Structured Clinical Interview for DSM-IV-TR, and the Symptom Checklist 90 (SCL-90, the Alcohol Use Disorder Identification Test (AUDIT, the Swedish universities Scales of Personality (SSP and the Sense of Coherence Scale (SOC, all self-report measures. Some measures were repeated every third month in addition to interviews. Results Of 123 patients admitted, 86 (70% remained in treatment after six months and 61 (50% remained in treatment after 12 months. Of those discharged involuntarily, 34/62 individuals were readmitted after a suspension period of three months. Younger age at intake, poly-substance abuse at intake (number of drugs in urine, and number of conduct disorder criteria on the SCID Screen were independently associated with an increased risk of involuntary discharge. There were no significant differences between dropouts and completers on SCL-90, SSP, SOC or AUDIT. Conclusion Of the patients admitted to the programme 50% stayed for the first 12 months with continuous abstinence and daily work. Poly-substance use before intake into treatment, high levels of conduct disorder on SCID

  4. Management of moderate to severe chronic low back pain with buprenorphine buccal film using novel bioerodible mucoadhesive technology

    Directory of Open Access Journals (Sweden)

    Pergolizzi Jr JV

    2016-10-01

    Full Text Available Joseph V Pergolizzi Jr,1 Robert B Raffa,2,3 Charles Fleischer,1 Gianpietro Zampogna,1 Robert Taylor Jr1 1NEMA Research, Naples, FL, 2University of Arizona College of Pharmacy, Tucson, AZ, 3Temple University School of Pharmacy, Philadelphia, PA, USA Abstract: With a global prevalence of ~9%–12%, low back pain (LBP is a serious public health issue, associated with high costs for treatment and lost productivity. Chronic LBP (cLBP involves central sensitization, a neuropathic pain component, and may induce maladaptive coping strategies and depression. Treating cLBP is challenging, and current treatment options are not fully satisfactory. A new BioErodible MucoAdhesive (BEMA® delivery system for buprenorphine has been developed to treat cLBP. The buccal buprenorphine (BBUP film developed for this product (Belbuca™ allows for rapid delivery and titration over a greater range of doses than was previously available with transdermal buprenorphine systems. In clinical studies, BBUP was shown to effectively reduce pain associated with cLBP at 12 weeks with good tolerability. The most frequently reported side effects with the use of BBUP were nausea, constipation, and vomiting. There was no significant effect on the QT interval vs placebo. Chronic pain patients using other opioids can be successfully rotated to BBUP without risk of withdrawal symptoms or inadequate analgesia. The role of BBUP in managing cLBP remains to be determined, but it appears to be a promising new product in the analgesic arsenal in general. Keywords: buccal, transmucosal, buprenorphine, chronic low back pain, BEMA, drug delivery Belbuca

  5. Urinary Excretion of Buprenorphine, Norbuprenorphine, Buprenorphine-Glucuronide, and Norbuprenorphine-Glucuronide in Pregnant Women Receiving Buprenorphine Maintenance Treatment

    Science.gov (United States)

    Kacinko, Sherri L.; Jones, Hendree E.; Johnson, Rolley E.; Choo, Robin E.; Concheiro-Guisan, Marta; Huestis, Marilyn A.

    2011-01-01

    BACKGROUND Buprenorphine (BUP) is under investigation as a medication therapy for opioid-dependent pregnant women. We investigated BUP and metabolite disposition in urine from women maintained on BUP during the second and third trimesters of pregnancy and postpartum. METHODS We measured BUP, norbuprenorphine (NBUP), buprenorphine glucuronide (BUP-Gluc), and NBUP-Gluc concentrations in 515 urine specimens collected thrice weekly from 9 women during pregnancy and postpartum. Specimens were analyzed using a fully validated liquid chromatography-mass spectrometry method with limits of quantification of 5 µg/L for BUP and BUP-Gluc and 25 µg/L for NBUP and its conjugated metabolite. We examined ratios of metabolites across trimesters and postpartum to identify possible changes in metabolism during pregnancy. RESULTS NBUP-Gluc was the primary metabolite identified in urine and exceeded BUP-Gluc concentrations in 99% of specimens. Whereas BUP-Gluc was identified in more specimens than NBUP, NBUP exceeded BUP-Gluc concentrations in 77.9% of specimens that contained both analytes. Among all participants, the mean BUP-Gluc:NBUP-Gluc ratio was significantly higher in the second trimester compared to the third trimester, and there were significant intrasubject differences between trimesters in 71% of participants. In 3 women, the percent daily dose excreted was higher during pregnancy than postpregnancy, consistent with other data indicating increased renal elimination of drugs during pregnancy. CONCLUSIONS These data are the first to evaluate urinary disposition of BUP and metabolites in a cohort of pregnant women. Variable BUP excretion during pregnancy may indicate metabolic changes requiring dose adjustment during later stages of gestation. PMID:19325013

  6. Effects of buprenorphine and meloxicam analgesia on induced cerebral ischemia in C57BL/6 male mice

    DEFF Research Database (Denmark)

    Jacobsen, Kirsten R; Fauerby, Natasha; Raida, Zindy

    2013-01-01

    Laboratory mice constitute an extensively used model to study the pathologic and functional outcomes of cerebral ischemic stroke. The middle cerebral artery occlusion (MCAO) model requires surgical intervention, which potentially can result in postsurgical pain and stress. In the present study, we...... investigated whether buprenorphine and meloxicam, at clinically relevant doses provided pain relief without altering infarct volume in male C57BL/6 mice. Common known side-effects of buprenorphine, including decreased food consumption, were noted after surgery in buprenorphine-treated mice, but these effects...

  7. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  8. Depression-like effect of prenatal buprenorphine exposure in rats.

    Directory of Open Access Journals (Sweden)

    Chih-Jen Hung

    Full Text Available Studies indicate that perinatal opioid exposure produces a variety of short- and long-term neurobehavioral consequences. However, the precise modes of action are incompletely understood. Buprenorphine, a mixed agonist/antagonist at the opioid receptors, is currently being used in clinical trials for managing pregnant opioid addicts. This study provides evidence of depression-like consequence following prenatal exposure to supra-therapeutic dose of buprenorphine and sheds light on potential mechanisms of action in a rat model involving administration of intraperitoneal injection to pregnant Sprague-Dawley rats starting from gestation day 7 and lasting for 14 days. Results showed that pups at postnatal day 21 but not the dams had worse parameters of depression-like neurobehaviors using a forced swimming test and tail suspension test, independent of gender. Neurobehavioral changes were accompanied by elevation of oxidative stress, reduction of plasma levels of brain-derived neurotrophic factor (BDNF and serotonin, and attenuation of tropomyosin-related kinase receptor type B (TrkB phosphorylation, extracellular signal-regulated kinase (ERK phosphorylation, protein kinase A activity, cAMP response element-binding protein (CREB phosphorylation, and CREB DNA-binding activity. Since BDNF/serotonin and CREB signaling could orchestrate a positive feedback loop, our findings suggest that the induction of oxidative stress, reduction of BDNF and serotonin expression, and attenuation of CREB signaling induced by prenatal exposure to supra-therapeutic dose of buprenorphine provide evidence of potential mechanism for the development of depression-like neurobehavior.

  9. Outcomes among buprenorphine-naloxone primary care patients after Hurricane Sandy.

    Science.gov (United States)

    Tofighi, Babak; Grossman, Ellie; Williams, Arthur R; Biary, Rana; Rotrosen, John; Lee, Joshua D

    2014-01-27

    The extent of damage in New York City following Hurricane Sandy in October 2012 was unprecedented. Bellevue Hospital Center (BHC), a tertiary public hospital, was evacuated and temporarily closed as a result of hurricane-related damages. BHC's large primary care office-based buprenorphine clinic was relocated to an affiliate public hospital for three weeks. The extent of environmental damage and ensuing service disruption effects on rates of illicit drug, tobacco, and alcohol misuse, buprenorphine medication supply disruptions, or direct resource losses among office-based buprenorphine patients is to date unknown. A quantitative and qualitative semi-structured survey was administered to patients in BHC's primary care buprenorphine program starting one month after the hurricane. Survey domains included: housing and employment disruptions; social and economic support; treatment outcomes (buprenorphine adherence and ability to get care), and tobacco, alcohol, and drug use. Open-ended questions probed general patient experiences related to the storm, coping strategies, and associated disruptions. There were 132 patients enrolled in the clinic at the time of the storm; of those, 91 patients were recruited to the survey, and 89 completed (98% of those invited). Illicit opioid misuse was rare, with 7 respondents reporting increased heroin or illicit prescription opioid use following Sandy. Roughly half of respondents reported disruption of their buprenorphine-naloxone medication supply post-event, and self-lowering of daily doses to prolong supply was common. Additional buprenorphine was obtained through unscheduled telephone or written refills from relocated Bellevue providers, informally from friends and family, and, more rarely, from drug dealers. The findings highlight the relative adaptability of public sector office-based buprenorphine treatment during and after a significant natural disaster. Only minimal increases in self-reported substance use were reported

  10. Advances in the delivery of buprenorphine for opioid dependence

    Directory of Open Access Journals (Sweden)

    Rosenthal RN

    2017-08-01

    Full Text Available Richard N Rosenthal,1 Viral V Goradia2 1Department of Psychiatry, Addiction Institute at Mount Sinai, Icahn School of Medicine at Mount Sinai, New York, 2Department of Psychiatry, Upstate Medical University, Syracuse, NY, USA Abstract: Opioid use disorders (OUDs have long been a global problem, but the prevalence rates have increased over 20 years to epidemic proportions in the US, with concomitant increases in morbidity and all-cause mortality, but especially opioid overdose. These increases are in part attributable to a several-fold expansion in the prescription of opioid pain medications over the same time period. Opioid detoxification and psychosocial treatments alone have each not yielded sufficient efficacy for OUD, but μ-opioid receptor agonist, partial agonist, and antagonist medications have demonstrated the greatest overall benefit in OUD treatment. Buprenorphine, a μ-opioid receptor partial agonist, has been used successfully on an international basis for several decades in sublingual tablet and film preparations for the treatment of OUD, but the nature of formulation, which is typically self-administered, renders it susceptible to nonadherence, diversion, and accidental exposure. This article reviews the clinical trial data for novel buprenorphine delivery systems in the form of subcutaneous depot injections, transdermal patches, and subdermal implants for the treatment of OUD and discusses both the clinical efficacy of longer-acting formulations through increasing consistent medication exposure and their potential utility in reducing diversion. These new delivery systems also offer new dosing opportunities for buprenorphine and strategies for dosing intervals in the treatment of OUD. Keywords: opioid use disorder, buprenorphine, drug diversion, drug implants, depot medications, maintenance therapy, treatment adherence

  11. [Addictive behavior after starting buprenorphine maintenance treatment].

    Science.gov (United States)

    Fanello, Serge; Daoud, Sidi; Panici, Jean Yves; Parot, Elsa; Hitoto, Hicombo; Garnier, François

    2006-02-01

    This study of a cohort of drug addicts receiving buprenorphine maintenance treatment in a district in western France focused on changes in their drug use and their social and work lives. It also looked at the health consequences of their drug use before and after maintenance treatment (mean: four years). From the files of an agency providing services to drug addicts, we randomly selected 180 of the 236 patients receiving buprenorphine maintenance treatment (BMT). Usable questionnaires were returned by 118 subjects (66% response rate). This self-administered questionnaire included 32 items. The respondents accounted for half the population receiving drug maintenance treatment and were representative of the population for age and sex. The mean age was 30 +/- 5 years, mean BMT dose 6,5 mg/day, and mean duration of drug maintenance treatment 47 +/- 27 months. Other drug use diminished during the four years of maintenance treatment: three of every four heroin users had stopped, opiate users dropped from 31% to 5% of the population, and cocaine use followed a similar trend. Benzodiazepine use also fell, but remained relatively frequent (27%, compared with 68% four years earlier). Drinking patterns changed from strongly alcoholic beverages to lower-proof drinks. Arrest rates dropped from 70% to 25%. The percentage of persons seropositive for HIV (4%) and HCV (33%) remained low, but too many subjects had not been screened (35%). Roughly 10% of these subjects had returned to work, mainly those who had cut their drug use most. While our survey reveals some positive points, especially a reduction in illegal drug use, several negative observations appeared, including combined use of cannabis and benzodiazepines, inadequate screening, and misuse of BMD. These results underline how important it is for care providers to focus simultaneously on medical treatment and identification of co-morbidities and to provide social work when necessary. The employment rate remains too low.

  12. Comparison of Intravenous Morphine with Sublingual Buprenorphine in Management of Postoperative Pain after Closed Reduction Orthopedic Surgery

    OpenAIRE

    Ghasem Soltani; Mahmood Khorsand; ALireza Sepehri Shamloo; Lida Jarahi; Nahid Zirak

    2015-01-01

    Background: Postoperative pain is a common side effect following surgery that can significantly reduce surgical quality and patient’s satisfaction. Treatment options are morphine and buprenorphine. We aimed to compare the efficacy of a single dose of intravenous morphine with sublingual buprenorphine in postoperative pain control following closed reduction surgery. Methods: This triple blind clinical trial was conducted on 90 patients referred for closed reduction orthopedic surgery. They wer...

  13. Successful medical treatment of glans ischemia after voluntary buprenorphine injection.

    Science.gov (United States)

    Brecheteau, François; Grison, Pierre; Abraham, Pierre; Lebdai, Souhil; Kemgang, Steve; Souday, Vincent; Nedelcu, Cosmina; Culty, Thibaut; Larré, Stéphane; Azzouzi, Abdel Rahmene; Bigot, Pierre

    2013-11-01

    The diverted use of synthetic opioid buprenorphine by drug addicts can be responsible for serious ischemic and infectious complications, particularly in the case of intravenous injection. We present a case of serious glans ischemia after buprenorphine injection directly into the deep dorsal vein of the penis. Analysis using new medical imaging techniques and treatments is detailed below. A 26-year-old male drug addict presented with glans pain 4 days after self-injection of buprenorphine into the deep dorsal vein of the penis. The patient was apyretic and presented a urethral discharge. His glans was blue without discoloration on digital pressure. Additionally, his biologic and serologic tests were normal while bacteriology showed the presence of Enterobacter cloacae urethritis. After 48 hours of intravenous antibiotic treatment without improvement, a specific medical treatment using enoxaparin and ilomedin was initiated, with the assumption that there was an ischemic complication. Laser speckle contrast imaging allowed confirmation of the presence of distal penis ischemia and provided an accurate mapping of the ischemic zone. A 28-day treatment combining antibiotics, subcutaneous heparin at curative dose, antiplatelet drug, ilomedin, and hyperbaric oxygen therapy resulted in clinical improvement of the lesions with no functional complications. To date, no consensus exists on the proper diagnostic and treatment approach to severe glans ischemia due to buprenorphine injection into the deep dorsal vein of the penis. The results of laser speckle contrast imaging were of real interest during the process of diagnosis. In addition, the combination of ilomedin with hyperbaric oxygen therapy and anticoagulant and antiplatelet drugs appeared to be an effective therapy. © 2013 International Society for Sexual Medicine.

  14. QT-interval effects of methadone, levomethadyl, and buprenorphine in a randomized trial.

    Science.gov (United States)

    Wedam, Erich F; Bigelow, George E; Johnson, Rolley E; Nuzzo, Paul A; Haigney, Mark C P

    2007-12-10

    Levomethadyl acetate, methadone hydrochloride, and buprenorphine hydrochloride are equally effective treatments for opioid dependence. Each blocks the human ether-a-go-go-related gene (hERG)-associated channel in vitro and represents a risk for QT prolongation. To compare the effects of 3 known hERG-associated channel blockers on the corrected QT (QTc), we conducted a randomized, controlled trial of opioid-addicted subjects. We analyzed 12-lead electrocardiograms collected at baseline and every 4 weeks from 165 opioid-addicted participants in a 17-week randomized double-blind clinical trial of equally effective doses of levomethadyl, methadone, and buprenorphine at a major referral center. Analyses were limited to the 154 patients with a normal baseline QTc = (QT/ radical R-R) who had at least 1 subsequent in-treatment electrocardiogram. Patients were randomized to receive treatment with levomethadyl, methadone, or buprenorphine (hereinafter, levomethadyl, methadone, and buprenorphine groups, respectively). The prespecified end points were a QTc greater than 470 milliseconds in men (or >490 milliseconds in women), or an increase from baseline in QTc greater than 60 milliseconds. Baseline QTc was similar in the 3 groups. The levomethadyl and methadone groups were significantly more likely to manifest a QTc greater than 470 or 490 milliseconds (28% for the levomethadyl group vs 23% for the methadone group vs 0% for the buprenorphine group; P methadone group [odds ratio, 8.4; 95% confidence interval, 1.9-36.4]) compared with the buprenorphine group (2% of subjects; P methadone remained fixed over at least 8 weeks, the QTc continued to increase progressively over time (P = .08 for the levomethadyl group, P = .01 for the methadone group). Buprenorphine is associated with less QTc prolongation than levomethadyl or methadone and may be a safe alternative.

  15. Pharmacokinetically guided dosing of (high-dose) chemotherapeutic agents

    NARCIS (Netherlands)

    Attema-de Jonge, M.E. (Milly Ellen)

    2004-01-01

    Due to variation in drug distribution, metabolism and elimination processes between patients, systemic exposure to chemotherapeutic agents may be highly variable from patient to patient after administration of similar doses. This pharmacokinetic variability may explain in part the large variability

  16. Methadone versus buprenorphine for the treatment of opioid abuse in pregnancy: science and stigma.

    Science.gov (United States)

    Holbrook, Amber M

    2015-01-01

    The past decade has seen an increase in rates of opioid abuse during pregnancy. This clinical challenge has been met with debate regarding whether or not illicit and prescription opioid-dependent individuals require different treatment approaches; whether detoxification is preferable to maintenance; and the efficacy of methadone versus buprenorphine as treatment options during pregnancy. The clinical recommendations resulting from these discussions are frequently influenced by the comparative stigma attached to heroin abuse and methadone maintenance versus prescription opioid abuse and maintenance treatment with buprenorphine. While some studies have suggested that a subset of individuals who abuse prescription opioids may have different characteristics than heroin users, there is currently no evidence to suggest that buprenorphine is better suited to treatment of prescription opioid abuse than methadone. Similarly, despite its perennial popularity, there is no evidence to recommend detoxification as an efficacious approach to treatment of opioid dependence during pregnancy. While increased access to treatment is important, particularly in rural areas, there are multiple medical and psychosocial reasons to recommend comprehensive substance abuse treatment for pregnant women suffering from substance use disorders rather than office-based provision of maintenance medication. Both methadone and buprenorphine are important treatment options for opioid abuse during pregnancy. Methadone may still remain the preferred treatment choice for some women who require higher doses for stabilization, have a higher risk of treatment discontinuation, or who have had unsuccessful treatment attempts with buprenorphine. As treatment providers, we should advocate to expand available treatment options for pregnant women in all States.

  17. Fiber optics in high dose radiation fields

    International Nuclear Information System (INIS)

    Partin, J.K.

    1985-01-01

    A review of the behavior of state-of-the-art optical fiber waveguides in high dose (greater than or equal to 10 5 rad), steady state radiation fields is presented. The influence on radiation-induced transmission loss due to experimental parameters such as dose rate, total dose, irradiation history, temperature, wavelength, and light intensity, for future work in high dose environments are given

  18. Extended vs Short-term Buprenorphine-Naloxone for Treatment of Opioid-Addicted Youth

    Science.gov (United States)

    Woody, George E.; Poole, Sabrina A.; Subramaniam, Geetha; Dugosh, Karen; Bogenschutz, Michael; Abbott, Patrick; Patkar, Ashwin; Publicker, Mark; McCain, Karen; Potter, Jennifer Sharpe; Forman, Robert; Vetter, Victoria; McNicholas, Laura; Blaine, Jack; Lynch, Kevin G.; Fudala, Paul

    2008-01-01

    Context The usual treatment for opioid-addicted youth is detoxification and counseling. Extended medication-assisted therapy may be more helpful. Objective To evaluate the efficacy of continuing buprenorphine-naloxone for 12 weeks vs detoxification for opioid-addicted youth. Design, Setting, and Patients Clinical trial at 6 community programs from July 2003 to December 2006 including 152 patients aged 15 to 21 years who were randomized to 12 weeks of buprenorphine-naloxone or a 14-day taper (detox). Interventions Patients in the 12-week buprenorphine-naloxone group were prescribed up to 24 mg per day for 9 weeks and then tapered to week 12; patients in the detox group were prescribed up to 14 mg per day and then tapered to day 14. All were offered weekly individual and group counseling. Main Outcome Measure Opioid-positive urine test result at weeks 4, 8, and 12. Results The number of patients younger than 18 years was too small to analyze separately, but overall, patients in the detox group had higher proportions of opioid-positive urine test results at weeks 4 and 8 but not at week 12 ( χ22 = 4.93, P = .09). At week 4, 59 detox patients had positive results (61%; 95% confidence interval [CI] = 47%-75%) vs 58 12-week buprenorphine-naloxone patients (26%; 95% CI = 14%-38%). At week 8, 53 detox patients had positive results (54%; 95% CI = 38%-70%) vs 52 12-week buprenorphine-naloxone patients (23%; 95% CI = 11%-35%). At week 12, 53 detox patients had positive results (51%; 95% CI = 35%-67%) vs 49 12-week buprenorphine-naloxone patients (43%; 95% CI = 29%-57%). By week 12, 16 of 78 detox patients (20.5%) remained in treatment vs 52 of 74 12-week buprenorphine-naloxone patients (70%; χ12 = 32.90, P < .001). During weeks 1 through 12, patients in the 12-week buprenorphine-naloxone group reported less opioid use ( χ12 = 18.45, P < .001), less injecting ( χ12 = 6.00, P = .01), and less nonstudy addiction treatment ( χ12 = 25.82, P < .001). High levels of opioid use

  19. Antinociceptive effects of voluntarily ingested buprenorphine in the hot-plate test in laboratory rats

    DEFF Research Database (Denmark)

    Kristensen, Sara Hestehave; Munro, Gordon; Brønnum Pedersen, Tina

    2017-01-01

    the animal to a thermal stimulus using a hot plate, significant antinociceptive effects of voluntarily ingested buprenorphine administered in Nutella® were demonstrated. This was evident at doses of 1.0 mg/kg 60 and 120 min post administration (Peffects were not as marked......Researchers performing experiments on animals should always strive towards the refinement of experiments, minimization of stress and provision of better animal welfare. An adequate analgesic strategy is important to improve post-operative recovery and welfare in laboratory rats and mice....... In addition, it is desirable to provide post-operative analgesia using methods that are minimally invasive and stressful. This study investigated the antinociceptive effects of orally administered buprenorphine ingested in Nutella® in comparison with subcutaneous buprenorphine administration. By exposing...

  20. A preliminary study comparing methadone and buprenorphine in patients with chronic pain and coexistent opioid addiction.

    Science.gov (United States)

    Neumann, Anne M; Blondell, Richard D; Jaanimägi, Urmo; Giambrone, Amanda K; Homish, Gregory G; Lozano, Jacqueline R; Kowalik, Urszula; Azadfard, Mohammadreza

    2013-01-01

    Patients with opioid addiction who receive prescription opioids for treatment of nonmalignant chronic pain present a therapeutic challenge. Fifty-four participants with chronic pain and opioid addiction were randomized to receive methadone or buprenorphine/naloxone. At the 6-month follow-up examination, 26 (48.1%) participants who remained in the study noted a 12.75% reduction in pain (P = 0.043), and no participants in the methadone group compared to 5 in the buprenorphine group reported illicit opioid use (P = 0.039). Other differences between the two conditions were not found. Long-term, low-dose methadone or buprenorphine/naloxone treatment produced analgesia in participants with chronic pain and opioid addiction.

  1. Developing and Implementing a New Prison-Based Buprenorphine Treatment Program

    Science.gov (United States)

    Kinlock, Timothy W.; Gordon, Michael S.; Schwartz, Robert P.; Fitzgerald, Terrence T.

    2010-01-01

    Research suggests that buprenorphine treatment may be a promising intervention for incarcerated individuals with heroin addiction histories. However, its implementation varies from corrections-based methadone because of unique challenges regarding dosing, administration, and regulation. Describing the first randomized clinical trial of…

  2. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  3. Comparison of Intravenous Morphine with Sublingual Buprenorphine in Management of Postoperative Pain after Closed Reduction Orthopedic Surgery.

    Science.gov (United States)

    Soltani, Ghasem; Khorsand, Mahmood; Shamloo, Alireza Sepehri; Jarahi, Lida; Zirak, Nahid

    2015-10-01

    Postoperative pain is a common side effect following surgery that can significantly reduce surgical quality and patient's satisfaction. Treatment options are morphine and buprenorphine. We aimed to compare the efficacy of a single dose of intravenous morphine with sublingual buprenorphine in postoperative pain control following closed reduction surgery. This triple blind clinical trial was conducted on 90 patients referred for closed reduction orthopedic surgery. They were older than 18 years and in classes I and II of the American Society of Anesthesiologists (ASA) with an operation time of 30-90 minutes. Patients were divided into two groups of buprenorphine (4.5µg/kg sublingually) and morphine (0.2mg/kg intravenously). Baseline characteristics, vital signs, pain score, level of sedation and pharmacological side effects were recorded in the recovery room (at 0 and 30 minutes), and in the ward (at 3, 6 and 12 hours). SPSS version 19 software was used for data analysis and the significance level was set at P<0.05. Ninety patients were studied, 60 males and 30 females with a mean age of 37.7±16.2 years. There was no significant difference between the two groups in terms of baseline characteristics. Pain score in the morphine group was significantly higher than the buprenorphine group with an average score of 2.5 (P<0.001). Postoperative mean heart rate in the buprenorphine group was four beats lower than the morphine group (P<0.001). Also, in the buprenorphine 48.6% and in the morphine group 86.7% of cases were conscious in recovery (P=0.001) with a higher rate of pruritus in the latter group (P=0.001). Sublingual buprenorphine administration before anesthesia induction in closed reduction surgery can lead to better postoperative pain control in comparison to intravenous morphine. Due to simple usage and longer postoperative sedation, sublingual buprenorphine is recommended as a suitable drug in closed reduction surgery.

  4. Buprenorphine and addiction: challenges for the pharmacist.

    Science.gov (United States)

    Boatwright, Deborah E

    2002-01-01

    To present an analysis of the Drug Addiction Treatment Act of 2000 (DATA) and its impact on the practice of pharmacy. Statutes, codes, regulations, newspaper articles, journal articles; search of articles posted on MEDLINE identified using the search terms methadone, buprenorphine, treatment, opioid abuse, and opioid addiction. Not applicable. Not applicable. DATA and Food and Drug Administration approval of sublingual tablets of buprenorphine and buprenorphine with naloxone (Reckitt and Benckiser) will dramatically expand opioid addicts' access to treatment and increase the number of opioid addicts receiving prescriptions for buprenorphine and buprenorphine with naloxone. The availability of buprenorphine will pose unique challenges to pharmacists and suggests the need for education on addiction and greater awareness of the unique needs of patients recovering from addiction. The stage is being set to expand access to treatment and reach more untreated opioid addicts in the United States. Professional organizations such as the American Pharmaceutical Association should work with the U.S. Department of Health and Human Services and its Substance Abuse and Mental Health Services Administration to develop training materials, curricula, and guidelines for pharmacists on substance abuse with a special focus on outpatient opioid treatment. Such materials could be used in continuing education programs and materials and in pharmacy schools.

  5. Progress in high-dose radiation dosimetry

    International Nuclear Information System (INIS)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.; Chadwick, K.H.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expanded applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Reference systems also include a number of chemical dose meters: ferrous sulphate, ferrous-cupric sulphate, and ceric sulphate acidic aqueous solutions. Requirements for stable and reliable transfer dose meters have led to further developments of several important high-dose systems: amino acids and saccharides analysed by ESR or lyoluminescence, thermoluminescent materials, radiochromic dyes and plastics, ceric-cerous solutions analysed by potentiometry, and ethanol-chlorobenzene solutions analysed by high-frequency oscillometry. A number of other prospective dose meters are also treated in this review. In addition, an IAEA programme of high-dose standardization and intercomparison for industrial radiation processing is described. (author)

  6. Sublingual buprenorphine is effective in the treatment of chronic pain syndrome.

    Science.gov (United States)

    Malinoff, Herbert L; Barkin, Robert L; Wilson, Geoffrey

    2005-01-01

    Many patients with chronic pain have less than optimal therapeutic outcomes after prolonged treatment with opiate analgesics. Worsening of pain perception, functional capacity, and mood often result. Medical detoxification is often undertaken in this situation. Ninety-five consecutive patients (49 men and 46 women; age range, 26-84) with chronic noncancer pain (maldynia) were referred by local pain clinics for detoxification from long-term opiate analgesic (LTOA) therapy. All patients had failed treatment as manifest by increasing pain levels, worsening functional capacity, and, in 8%, the emergence of opiate addiction. Length of prior LTOA therapy ranged from 1.5 to 27 years (mean, 8.8 years). After a minimum of 12 hours of abstinence from all opiate analgesics, patients were given low doses of sublingual (SL) buprenorphine or buprenorphine/naloxone (Reckitt Benckiser). Maintenance dosing was individualized to treat chronic pain. Daily SL dose of buprenorphine ranged from 4 to 16 mg (mean, 8 mg) in divided doses. Mean duration of treatment is 8.8 months (range, 2.4-16.6 months). At clinic appointments, patients were assessed for pain reports, functional capacity, and mood inventory. Eighty-six percent of patients experienced moderate to substantial relief of pain accompanied by both improved mood and functioning. Patient and family satisfaction was robust. Only 6 patients discontinued therapy secondary to side effects and/or exacerbation of pain. In this open-label study, SL buprenorphine and buprenorphine/naloxone were well tolerated and safe and appeared to be effective in the treatment of chronic pain patients refractory to LTOA.

  7. The extramedical use and diversion of opioid substitution medications and other medications in prison settings in Australia following the introduction of buprenorphine-naloxone film.

    Science.gov (United States)

    White, Nancy; Ali, Robert; Larance, Briony; Zador, Deborah; Mattick, Richard P; Degenhardt, Louisa

    2016-01-01

    Around 65% of people incarcerated in prisons in Australia, America and Europe have a history of drug dependence, sometimes treated with opioid substitution treatment (OST) medications. Studies report that those in treatment in prison do engage in some level of diversion to others, whether on a voluntary or coerced basis. We aimed to examine the use of prescribed and non-prescribed OST medications by those in prisons, especially buprenorphine-naloxone film (BNX-F); the extent of non-adherence and diversion and reasons for such practices; and the impact of the introduction of BNX-F into the prison system. Mixed methods study drawing on: (i) structured interviews with current OST clients (n = 60) who reported being incarcerated in the 12 months prior to being interviewed and (ii) qualitative interviews with key experts working in corrections and prison (or justice) health settings. The majority were prescribed OST medications in prison, with 25% removing all or part of their supervised dose on at least one occasion, and 44% reporting use of non-prescribed medications. Some reported intravenous use (14% injected). One-third of OST recipients reported selling/sharing OST medications with others in prison. The introduction of BNX-F into the prison system saw different diversion methods used and removal from dosing within prison. Despite prison being a highly regulated and controlled environment, some level of diversion and sharing of psychoactive medication occurs among prisoners. The buprenorphine formulations used in OST present particular challenges with respect to supervised dosing in this setting. [White N, Ali R, Larance B, Zador D, Mattick RP, Degenhardt L. The extramedical use and diversion of opioid substitution medications and other medications in prison settings in Australia following the introduction of buprenorphine-naloxone film. Drug Alcohol Rev 2015;●●:●●-●●]. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  8. High-dose irradiation of food

    International Nuclear Information System (INIS)

    Diehl, J.F.

    1999-01-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [de

  9. Reversal of Stress-Induced Social Interaction Deficits by Buprenorphine.

    Science.gov (United States)

    Browne, Caroline A; Falcon, Edgardo; Robinson, Shivon A; Berton, Olivier; Lucki, Irwin

    2018-02-01

    Patients with post-traumatic stress disorder frequently report persistent problems with social interactions, emerging after a traumatic experience. Chronic social defeat stress is a widely used rodent model of stress that produces robust and sustained social avoidance behavior. The avoidance of other rodents can be reversed by 28 days of treatment with selective serotonin reuptake inhibitors, the only pharmaceutical class approved by the U.S. Food and Drug Administration for treating post-traumatic stress disorder. In this study, the sensitivity of social interaction deficits evoked by 10 days of chronic social defeat stress to prospective treatments for post-traumatic stress disorder was examined. The effects of acute and repeated treatment with a low dose of buprenorphine (0.25 mg/kg/d) on social interaction deficits in male C57BL/6 mice by chronic social defeat stress were studied. Another cohort of mice was used to determine the effects of the selective serotonin reuptake inhibitor fluoxetine (10 mg/kg/d), the NMDA antagonist ketamine (10 mg/kg/d), and the selective kappa opioid receptor antagonist CERC-501 (1 mg/kg/d). Changes in mRNA expression of Oprm1 and Oprk1 were assessed in a separate cohort. Buprenorphine significantly reversed social interaction deficits produced by chronic social defeat stress following 7 days of administration, but not after acute injection. Treatment with fluoxetine for 7 days, but not 24 hours, also reinstated social interaction behavior in mice that were susceptible to chronic social defeat. In contrast, CERC-501 and ketamine failed to reverse social avoidance. Gene expression analysis found: (1) Oprm1 mRNA expression was reduced in the hippocampus and increased in the frontal cortex of susceptible mice and (2) Oprk1 mRNA expression was reduced in the amygdala and increased in the frontal cortex of susceptible mice compared to non-stressed controls and stress-resilient mice. Short-term treatment with buprenorphine and fluoxetine

  10. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  11. Radiation effects of high and low doses

    International Nuclear Information System (INIS)

    El-Naggar, A.M.

    1998-01-01

    The extensive proliferation of the uses and applications of atomic and nuclear energy resulted in possible repercussions on human health. The prominent features of the health hazards that may be incurred after exposure to high and low radiation doses are discussed. The physical and biological factors involved in the sequential development of radiation health effects and the different cellular responses to radiation injury are considered. The main criteria and features of radiation effects of high and low doses are comprehensively outlined

  12. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  13. Intracranial meningiomas after high-dose irradiation

    International Nuclear Information System (INIS)

    Soffer, D.; Gomori, J.M.; Siegal, T.; Shalit, M.N.

    1989-01-01

    Three patients who presented with intracranial meningiomas 12, 15, and 20 years, respectively, after therapeutic high-dose irradiation of a primary brain tumor are described. Analysis of these cases and similar documented cases suggests that meningiomas after high-dose irradiation constitute a recognizable entity. Patients with such tumors received radiation therapy at a young age (mean age, 9.4 years). After a latent period of 2 to 47 years (mean, 19.8 years) they developed meningiomas at the site of irradiation, at a much younger age than patients with ''spontaneous'' meningiomas. Similar to the situation with meningiomas after low-dose irradiation, a relatively high proportion of meningiomas induced by high-dose irradiation tend to be malignant and biologically aggressive. A very young age at the time of irradiation seems to predispose to the induction of malignant meningiomas, rather than benign tumors. These unusual features provide indirect evidence that high-dose radiation may play a role in the pathogenesis of meningiomas.41 references

  14. Effect of Buprenorphine Weekly Depot (CAM2038) and Hydromorphone Blockade in Individuals With Opioid Use Disorder: A Randomized Clinical Trial.

    Science.gov (United States)

    Walsh, Sharon L; Comer, Sandra D; Lofwall, Michelle R; Vince, Bradley; Levy-Cooperman, Naama; Kelsh, Debra; Coe, Marion A; Jones, Jermaine D; Nuzzo, Paul A; Tiberg, Fredrik; Sheldon, Behshad; Kim, Sonnie

    2017-09-01

    Buprenorphine is an efficacious, widely used treatment for opioid use disorder (OUD). Daily oral transmucosal formulations can be associated with misuse, diversion, and nonadherence; these limitations may be obviated by a sustained release formulation. To evaluate the ability of a novel, weekly, subcutaneous buprenorphine depot formulation, CAM2038, to block euphorigenic opioid effects and suppress opioid withdrawal in non-treatment-seeking individuals with OUD. This multisite, double-blind, randomized within-patient study was conducted at 3 controlled inpatient research facilities. It involved 47 adults with DSM-V moderate-to-severe OUD. The study was conducted from October 12, 2015 (first patient enrolled), to April 21, 2016 (last patient visit). A total of five 3-day test sessions evaluated the response to hydromorphone (0, 6, and 18 mg intramuscular in random order; 1 dose/session/day). After the first 3-day session (ie, qualification phase), participants were randomized to either CAM2038 weekly at 24 mg (n = 22) or 32 mg (n = 25); the assigned CAM2038 dose was given twice, 1 week apart (day 0 and 7). Four sets of sessions were conducted after randomization (days 1-3, 4-6, 8-10, and 11-13). The primary end point was maximum rating on the visual analog scale for drug liking. Secondary end points included other visual analog scale (eg, high and desire to use), opioid withdrawal scales, and physiological and pharmacokinetic outcomes. A total of 46 of 47 randomized participants (mean [SD] age, 35.5 [9] years; 76% male [n = 35]) completed the study. Both weekly CAM2038 doses produced immediate and sustained blockade of hydromorphone effects (liking maximum effect, CAM2038, 24 mg: effect size, 0.813; P withdrawal (Clinical Opiate Withdrawal Scale, CAM2038, 24 mg: effect size, 0.617; P opioid blockade and withdrawal suppression. The results support the use of this depot formulation for treatment initiation and stabilization of patients with OUD, with

  15. Extended vs short-term buprenorphine-naloxone for treatment of opioid-addicted youth: a randomized trial.

    Science.gov (United States)

    Woody, George E; Poole, Sabrina A; Subramaniam, Geetha; Dugosh, Karen; Bogenschutz, Michael; Abbott, Patrick; Patkar, Ashwin; Publicker, Mark; McCain, Karen; Potter, Jennifer Sharpe; Forman, Robert; Vetter, Victoria; McNicholas, Laura; Blaine, Jack; Lynch, Kevin G; Fudala, Paul

    2008-11-05

    The usual treatment for opioid-addicted youth is detoxification and counseling. Extended medication-assisted therapy may be more helpful. To evaluate the efficacy of continuing buprenorphine-naloxone for 12 weeks vs detoxification for opioid-addicted youth. Clinical trial at 6 community programs from July 2003 to December 2006 including 152 patients aged 15 to 21 years who were randomized to 12 weeks of buprenorphine-naloxone or a 14-day taper (detox). Patients in the 12-week buprenorphine-naloxone group were prescribed up to 24 mg per day for 9 weeks and then tapered to week 12; patients in the detox group were prescribed up to 14 mg per day and then tapered to day 14. All were offered weekly individual and group counseling. Opioid-positive urine test result at weeks 4, 8, and 12. The number of patients younger than 18 years was too small to analyze separately, but overall, patients in the detox group had higher proportions of opioid-positive urine test results at weeks 4 and 8 but not at week 12 (chi(2)(2) = 4.93, P = .09). At week 4, 59 detox patients had positive results (61%; 95% confidence interval [CI] = 47%-75%) vs 58 12-week buprenorphine-naloxone patients (26%; 95% CI = 14%-38%). At week 8, 53 detox patients had positive results (54%; 95% CI = 38%-70%) vs 52 12-week buprenorphine-naloxone patients (23%; 95% CI = 11%-35%). At week 12, 53 detox patients had positive results (51%; 95% CI = 35%-67%) vs 49 12-week buprenorphine-naloxone patients (43%; 95% CI = 29%-57%). By week 12, 16 of 78 detox patients (20.5%) remained in treatment vs 52 of 74 12-week buprenorphine-naloxone patients (70%; chi(2)(1) = 32.90, P < .001). During weeks 1 through 12, patients in the 12-week buprenorphine-naloxone group reported less opioid use (chi(2)(1) = 18.45, P < .001), less injecting (chi(2)(1) = 6.00, P = .01), and less nonstudy addiction treatment (chi(2)(1) = 25.82, P < .001). High levels of opioid use occurred in both groups at follow-up. Four of 83 patients who tested

  16. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  17. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  18. Evaluation of the Tolerability of Switching Patients on Chronic Full ?-Opioid Agonist Therapy to Buccal Buprenorphine

    OpenAIRE

    Webster, Lynn; Gruener, Daniel; Kirby, Todd; Xiang, Qinfang; Tzanis, Evan; Finn, Andrew

    2016-01-01

    Objective?Assess whether patients with chronic pain receiving 80 to 220?mg oral morphine sulfate equivalent of a full ?-opioid agonist could be transitioned to buccal buprenorphine at approximately 50% of their full dose without inducing opioid withdrawal or sacrificing analgesic efficacy. Methods.?A randomized, double-blind, double-dummy, active-controlled, two-period crossover study in adult patients receiving around-the-clock full opioid agonist therapy and confirmed to be opioid dependent...

  19. Diversion and injection of buprenorphine-naloxone film two years post-introduction in Australia.

    Science.gov (United States)

    Larance, Briony; Mattick, Richard; Ali, Robert; Lintzeris, Nicholas; Jenkinson, Rebecca; White, Nancy; Kihas, Ivana; Cassidy, Rosemary; Degenhardt, Louisa

    2016-01-01

    We report 2 years of post-marketing surveillance of the diversion and injection of buprenorphine-naloxone (BNX) film following its introduction in 2011. Interviews were conducted with people who inject drugs regularly (PWID) (2004-2013), opioid substitution therapy clients (2013, n = 492) and key experts (n = 44). Key outcomes were unsanctioned removal of supervised doses, diversion, injection and street price. Prevalence of past 6-month injection among PWID was adjusted for background availability of opioid substitution therapy medications using sales data. Among out-of-treatment PWID, the levels of regular (weekly+) BNX film injection were comparable to methadone and BNX tablets, and lower than mono-buprenorphine, adjusting for background availability. Fewer BNX film clients [3%; 95% (CI) 1-5] regularly injected their medication than mono-buprenorphine clients (25%; 95% CI 11-39), but at levels equivalent to those among methadone (3%; 95% CI 1-6) and BNX tablet clients (2%; 95% CI 0-6). Key experts perceived BNX film needed less supervised dosing time as it dissolved rapidly and was harder to remove from the mouth than sublingual tablets; however, removal of supervised doses was higher among BNX film clients (15%; 95% CI: 10-20) than methadone clients (3%; 95% CI 1-6), and not significantly different from BNX tablet (11%; 95% CI 2-21) and mono-buprenorphine clients (31%; 95% CI 16-46). Two years post-introduction, levels of BNX film diversion and injection remained comparable with those for methadone and BNX tablets, and lower than mono-buprenorphine. We found no evidence that BNX film has lower non-adherence and diversion than the tablet formulation. [Larance B, Mattick R, Ali R, Lintzeris N, Jenkinson R, White N, Kihas I, Cassidy R, Degenhardt L. Diversion and injection of buprenorphine-naloxone film two years post-introduction in Australia. Drug Alcohol Rev 2015]. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  20. Preliminary investigation comparing a detomidine continuous rate infusion combined with either morphine or buprenorphine for standing sedation in horses.

    Science.gov (United States)

    Potter, Joanna J; MacFarlane, Paul D; Love, Emma J; Tremaine, Henry; Taylor, Polly M; Murrell, Joanna C

    2016-03-01

    To compare sedative and analgesic properties of buprenorphine or morphine for standing procedures combined with a detomidine continuous rate infusion (CRI). Blinded, prospective, randomized clinical pilot study. Ten horses presented for dental or sinus procedures. Horses received 0.02 mg kg(-1) acepromazine intravenously (IV), followed 30 minutes later by detomidine 10 μg kg(-1) IV. Five minutes later, buprenorphine 0.01 mg kg(-1) (n = 6) or morphine 0.1 mg kg(-1) (n = 4) was administered IV. Detomidine was administered by CRI (0.2 μg kg(-1) minute(-1)) and adjusted to maintain appropriate sedation. Heart rate, respiratory frequency, gastrointestinal motility and rectal temperature were measured; pain, ataxia and sedation were scored. Sedation, pain scores and ataxia scores were analysed using a mixed linear model. Detomidine dose and procedure success scores were compared using Wilcoxon's rank sum test. Complications between groups were analysed using Fisher's exact test. Two horses had incomplete data. Weights and ages were not different between groups (p = 0.15 and p = 0.42, respectively). The dose rate for detomidine was not different between groups (0.33 ± 0.02 μg kg(-1) minute(-1) in the buprenorphine group and 0.33 ± 0.05 μg kg(-1) minute(-1), in the morphine group p = 0.89). Intraoperative visual analogue scale scores were greater after buprenorphine than morphine (mean ± SD, buprenorphine 48 ± 4, morphine 40 ± 5, p = 0.0497). Procedure duration was not different between groups (buprenorphine 142 ± 33, morphine 140 ± 12 minutes). All horses treated with buprenorphine experienced complications compared with none in the morphine group (p = 0.0286). At the doses used, buprenorphine produced greater sedation but more post-operative complications than morphine. However, Type I or Type II errors cannot be excluded and larger studies are required to confirm these findings. © 2015 Association of Veterinary Anaesthetists and the American College of

  1. Nonlinear model of high-dose implantation

    International Nuclear Information System (INIS)

    Danilyuk, A.

    2001-01-01

    The models of high-dose implantation, using the distribution functions, are relatively simple. However, they must take into account the variation of the function of distribution of the implanted ions with increasing dose [1-4]. This variation takes place owing to the fact that the increase of the concentration of the implanted ions results in a change of the properties of the target. High-dose implantation is accompanied by sputtering, volume growth, diffusion, generation of defects, formation of new phases, etc. The variation of the distribution function is determined by many factors and is not known in advance. The variation within the framework of these models [1-4] is taken into account in advance by the introduction of intuitive assumptions on the basis of implicit considerations. Therefore, these attempts should be regarded as incorrect. The model prepared here makes it possible to take into account the sputtering of the target, volume growth and additional declaration on the implanted ions. Without any assumptions in relation to the variation of the distribution function with increasing dose. In our model it is assumed that the type of distribution function for small doses in a pure target substance is the same as in substances with implanted ions. A second assumption relates to the type of the distribution function valid for small doses in the given substances. These functions are determined as a result of a large number of theoretical and experimental investigations and are well-known at the present time. They include the symmetric and nonsymmetric Gauss distribution, the Pearson distribution, and others. We examine implantation with small doses of up to 10 14 - 10 15 cm -2 when the accurately known distribution is valid

  2. High dose gamma-ray standard

    International Nuclear Information System (INIS)

    Macrin, R.; Moraru, R.

    1999-01-01

    The high gamma-ray doses produced in a gamma irradiator are used, mainly, for radiation processing, i.e. sterilization of medical products, processing of food, modifications of polymers, irradiation of electronic devices, a.s.o. The used absorbed doses depend on the application and cover the range 10 Gy to 100 MGy. The regulations in our country require that the response of the dosimetry systems, used for the irradiation of food and medical products, be calibrated and traceable to the national standards. In order to be sure that the products receive the desired absorbed dose, appropriate dosimetric measurements must be performed, including the calibration of the dosemeters and their traceability to the national standards. The high dose gamma-ray measurements are predominantly based on the use of reference radiochemical dosemeters. Among them the ferrous sulfate can be used as reference dosemeter for low doses (up to 400 Gy) but due to its characteristics it deserves to be considered a standard dosemeter and to be used for transferring the conventional absorbed dose to other chemical dosemeters used for absorbed doses up to 100 MGy. The study of the ferrous sulfate dosemeter consisted in preparing many batches of solution by different operators in quality assurance conditions and in determining for all batches the linearity, the relative intrinsic error, the repeatability and the reproducibility. The principal results are the following: the linear regression coefficient: 0.999, the relative intrinsic error: max.6 %, the repeatability (for P* = 95 %): max.3 %, the reproducibility (P* = 95%): max.5 %. (authors)

  3. Improved memory for reward cues following acute buprenorphine administration in humans.

    Science.gov (United States)

    Syal, Supriya; Ipser, Jonathan; Terburg, David; Solms, Mark; Panksepp, Jaak; Malcolm-Smith, Susan; Bos, Peter A; Montoya, Estrella R; Stein, Dan J; van Honk, Jack

    2015-03-01

    In rodents, there is abundant evidence for the involvement of the opioid system in the processing of reward cues, but this system has remained understudied in humans. In humans, the happy facial expression is a pivotal reward cue. Happy facial expressions activate the brain's reward system and are disregarded by subjects scoring high on depressive mood who are low in reward drive. We investigated whether a single 0.2mg administration of the mixed mu-opioid agonist/kappa-antagonist, buprenorphine, would influence short-term memory for happy, angry or fearful expressions relative to neutral faces. Healthy human subjects (n38) participated in a randomized placebo-controlled within-subject design, and performed an emotional face relocation task after administration of buprenorphine and placebo. We show that, compared to placebo, buprenorphine administration results in a significant improvement of memory for happy faces. Our data demonstrate that acute manipulation of the opioid system by buprenorphine increases short-term memory for social reward cues. Copyright © 2015. Published by Elsevier Ltd.

  4. NIST high-dose calibration services

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1989-01-01

    There is a need for the standardization of high-dose measurements used in the radiation-processing industry in order to provide assured traceability to national standards. NIST provides dosimetry calibration services to this industry. One of these services involves administration of known absorbed doses of gamma rays to customer-supplied dosimeters. The dosimeters are packaged to provide electron equilibrium conditions and are irradiated in a standard 60 Co calibration facility; this provides a calibration of that batch of dosimeters. Another service consists of supplying to a customer calibrated transfer dosimeters for irradiation with the customer's radiation source. The irradiated transfer dosimeters are then returned to NIST for analysis; the results are reported to the customer, providing a calibration of the dose rate of the customer's source. (orig.)

  5. Injectable naltrexone, oral naltrexone, and buprenorphine utilization and discontinuation among individuals treated for opioid use disorder in a United States commercially insured population.

    Science.gov (United States)

    Morgan, Jake R; Schackman, Bruce R; Leff, Jared A; Linas, Benjamin P; Walley, Alexander Y

    2018-02-01

    with oral naltrexone, 31% for individuals treated with sublingual or oralmucosal buprenorphine/naloxone, 58% for individuals treated with sublingual buprenorphine, and 51% for individuals treated with transdermal buprenorphine discontinued treatment. In the Cox proportional hazard model, use of injectable naltrexone, oral naltrexone, sublingual buprenorphine, and transdermal buprenorphine were all associated with significantly greater hazard of discontinuing therapy beginning >30days after MOUD initiation (HR=2.17, 2.54, 1.15, and 2.21, respectively, 95% CIs 2.04-2.30, 2.45-2.64, 1.10-1.19, and 2.11-2.33), compared with the use of sublingual or oralmucosal buprenorphine/naloxone. This analysis demonstrates that the use of evidence-based medication therapies has not kept pace with increases in OUD diagnoses in commercially insured populations in the United States. Among those who have been treated, discontinuation rates >30days after initiation are high. The proportion treated with injectable naltrexone, oral naltrexone, and transdermal buprenorphine grew over time but remains small, and the discontinuation rates are higher among those treated with these medications compared with those treated with sublingual or oralmucosal buprenorphine/naloxone. In the face of the opioid overdose and addiction crisis, new efforts are needed at the provider, health system, and policy levels so that MOUD availability and uptake keep pace with new OUD diagnoses and OUD treatment discontinuation is minimized. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Prospective multicenter observational study of 260 infants born to 259 opiate-dependent mothers on methadone or high-dose buprenophine substitution.

    Science.gov (United States)

    Lejeune, Claude; Simmat-Durand, Laurence; Gourarier, Laurent; Aubisson, Sandrine

    2006-05-20

    Specialized prenatal care and substitution programs improve the perinatal prognoses of pregnant drug-abusers and their infants. Although methadone is well documented, little is known about high-dose buprenorphine (HDB). This prospective, multicenter (n = 35) observational study included 259 women on maintenance during pregnancy: 39% on methadone and 61% on HDB. Major findings were: 46% of them received good prenatal care; 62% had peridural analgesia; 12.3% delivered prematurely (hydrochloride. No baby died. Newborns were discharged with their mothers (96%) or placed in foster care (4%). Comparing methadone with HDB, respectively, mean age at the maximum Lipsitz score was 81 h versus 66 h (P = 0.066). The perinatal medical and social prognoses for these 259 drug addicts and their infants appeared to be improved by specialized prenatal care and was similar for methadone or BHD substitution during pregnancy.

  7. High-dose erythropoietin for tissue protection

    DEFF Research Database (Denmark)

    Lund, Anton; Lundby, Carsten; Olsen, Niels Vidiendal

    2014-01-01

    BACKGROUND: The discovery of potential anti-apoptotic and cytoprotective effects of recombinant human erythropoietin (rHuEPO) has led to clinical trials investigating the use of high-dose, short-term rHuEPO therapy for tissue protection in conditions such as stroke and myocardial infarction....... Experimental studies have been favourable, but the clinical efficacy has yet to be validated. MATERIALS AND METHODS: We have reviewed clinical studies regarding the use of high-dose, short-term rHuEPO therapy for tissue protection in humans with the purpose to detail the safety and efficacy of r...... no effect of rHuEPO therapy on measures of tissue protection. Five trials including 1025 patients reported safety concerns in the form of increased mortality or adverse event rates. No studies reported reduced mortality. CONCLUSIONS: Evidence is sparse to support a tissue-protective benefit of r...

  8. Effects of buprenorphine and hepatitis C on liver enzymes in adolescents and young adults.

    Science.gov (United States)

    Bogenschutz, Michael P; Abbott, Patrick J; Kushner, Robert; Tonigan, J Scott; Woody, George E

    2010-12-01

    The purpose of this study was to explore changes in transaminase values associated with buprenorphine treatment and hepatitis C status among opioid dependent subjects aged 15-21. 152 subjects seeking treatment for opioid dependence were randomized to 2-week detoxification with buprenorphine/naloxone (DETOX) or 12 weeks buprenorphine/naloxone (BUP). Liver chemistries including transaminases were obtained baseline and at 4, 8, and 12 weeks. 111 patients had at least one set of transaminases during treatment and were included in analyses of treatment effects. Overall, 8/60 BUP participants vs. 12/51 DETOX participants had at least one elevated ALT value during follow-up (Chi-square n.s.). 5/60 BUP participants vs. 11/51 DETOX participants had at least one elevated AST value (Chi-square = 3.194, p = .048). Twenty-eight out of 152 participants were hepatitis C (HCV) positive at baseline, and 4 seroconverted within 12 weeks, 2 in each group. HCV status was significantly associated with transaminase abnormalities (p = .009 and p = .006 for ALT an AST, respectively). HCV status had a strong effect on transaminase abnormalities among participants assigned to DETOX, but not among those assigned to BUP. No evidence was found for hepatotoxicity of buprenorphine in this exploratory analysis. HCV was present in a significant minority of participants and was a significant predictor of transaminase elevation. Results suggest that stabilization on buprenorphine may decrease the frequency of transaminase abnormalities associated with HCV in opioid dependent young people. The high rate of seroconversion underscores the importance of effective treatment and prevention.

  9. Buprenorphine Implants for Treatment of Opioid Dependence: Randomized Comparison to Placebo and Sublingual Buprenorphine/Naloxone

    Science.gov (United States)

    Rosenthal, Richard N.; Ling, Walter; Casadonte, Paul; Vocci, Frank; Bailey, Genie L.; Kampman, Kyle; Patkar, Ashwin; Chavoustie, Steven; Blasey, Christine; Sigmon, Stacey; Beebe, Katherine L.

    2015-01-01

    Aims To evaluate safety and efficacy of buprenorphine implants (BI) versus placebo implants (PI) for the treatment of opioid dependence. A secondary aim compared BI to open-label sublingual buprenorphine/naloxone tablets (BNX). Design Randomized, double-blind, placebo-controlled trial. Subjects received either 4 buprenorphine implants (80 mg/implant) (n=114), 4 placebo implants (n=54), or open-label BNX (12–16 mg/d) (n=119). Setting 20 addiction treatment centers. Participants Adult outpatients (ages 18 to 65) with DSM-IV-TR opioid dependence. Measurements The primary efficacy endpoint was the percent of urine samples negative for opioids collected from weeks 1 to 24, examined as a cumulative distribution function (CDF). Findings The BI CDF was significantly different from placebo (P<.0001). Mean (95% CI) proportions of urines negative for opioids were: BI: 31.2% (25.3, 37.1) and PI: 13.4% (8.3, 18.6). BI subjects had a higher study completion rate relative to placebo (64% vs. 26%, P<.0001), lower clinician-rated (P<.0001) and patient-rated (P<.0001) withdrawal, lower patient-ratings of craving (P<.0001), and better subjects’ (P=.031) and clinicians’ (P=.022) global ratings of improvement. BI also resulted in significantly lower cocaine use (P=.0016). Minor implant-site reactions were comparable in the buprenorphine (27.2% [31/114]) and placebo groups (25.9% [14/54]). BI were non-inferior to BNX on percent urines negative for opioids [mean (95% CI): 33.5 (27.3, 39.6); CI for the difference of proportions, (−10.7, 6.2)]. Conclusions Compared with placebo, buprenorphine implants result in significantly less frequent opioid use, and are non-inferior to sublingual buprenorphine/naloxone tablets. PMID:23919595

  10. High dose rate brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Koizumi, Masahiko; Ogawa, Kazuhiko; Furukawa, Souhei

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. (author)

  11. High dose rate brachytherapy for oral cancer.

    Science.gov (United States)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  12. Update on pediatric resuscitation drugs: high dose, low dose, or no dose at all.

    Science.gov (United States)

    Sorrentino, Annalise

    2005-04-01

    Pediatric resuscitation has been a topic of discussion for years. It is difficult to keep abreast of changing recommendations, especially for busy pediatricians who do not regularly use these skills. This review will focus on the most recent guidelines for resuscitation drugs. Three specific questions will be discussed: standard dose versus high-dose epinephrine, amiodarone use, and the future of vasopressin in pediatric resuscitation. The issue of using high-dose epinephrine for cardiopulmonary resuscitation refractory to standard dose epinephrine has been a topic of debate for many years. Recently, a prospective, double-blinded study was performed to help settle the debate. These results will be reviewed and compared with previous studies. Amiodarone is a medication that was added to the pediatric resuscitation algorithms with the most recent recommendations from the American Heart Association in 2000. Its use and safety will also be discussed. Another topic that is resurfacing in resuscitation is the use of vasopressin. Its mechanism and comparisons to other agents will be highlighted, although its use in the pediatric patient has not been thoroughly studied. Pediatric resuscitation is a constantly evolving subject that is on the mind of anyone taking care of sick children. Clinicians are continually searching for the most effective methods to resuscitate children in terms of short- and long-term outcomes. It is important to be familiar with not only the agents being used but also the optimal way to use them.

  13. High dose rate endobronchial brachytherapy - treatment technique

    International Nuclear Information System (INIS)

    Carvalho, Heloisa de Andrade; Aisen, Salim; Haddad, Cecilia Maria Kalil; Nadalin, Wladimir; Pedreira Junior, Wilson Leite; Chavantes, Maria Cristina

    1998-01-01

    High dose rate endobronchial brachytherapy is efficient in symptom relief due to obstructive endobronchial malignancies. However, it's role in survival improvement for patients with lung cancer is not yet established. The use of this treatment in increasing, specially in the developing countries. The purpose of this paper is to present the treatment technique used in the Radiotherapy Department of the Hospital da Clinicas, University of Sao Paulo, based on an experience of 60 cases treated with 180 procedures. Some practical suggestions and rules adopted in the Department are described. The severe complications rate is 6.7%, demonstrating an adequate patient selection associated with the technique utilized. (author)

  14. Neuroprotective potential of high-dose biotin.

    Science.gov (United States)

    McCarty, Mark F; DiNicolantonio, James J

    2017-11-01

    A recent controlled trial has established that high-dose biotin supplementation - 100 mg, three times daily - has a stabilizing effect on progression of multiple sclerosis (MS). Although this effect has been attributed to an optimization of biotin's essential cofactor role in the brain, a case can be made that direct stimulation of soluble guanylate cyclase (sGC) by pharmacological concentrations of biotin plays a key role in this regard. The utility of high-dose biotin in MS might reflect an anti-inflammatory effect of cGMP on the cerebral microvasculature, as well on oligodendrocyte differentiation and on Schwann cell production of neurotrophic factors thought to have potential for managing MS. But biotin's ability to boost cGMP synthesis in the brain may have broader neuroprotective potential. In many types of neurons and neural cells, cGMP exerts neurotrophic-mimetic effects - entailing activation of the PI3K-Akt and Ras-ERK pathways - that promote neuron survival and plasticity. Hippocampal long term potentiation requires nitric oxide synthesis, which in turn promotes an activating phosphorylation of CREB via a pathway involving cGMP and protein kinase G (PKG). In Alzheimer's disease (AD), amyloid beta suppresses this mechanism by inhibiting sGC activity; agents which exert a countervailing effect by boosting cGMP levels tend to restore effective long-term potentiation in rodent models of AD. Moreover, NO/cGMP suppresses amyloid beta production within the brain by inhibiting expression of amyloid precursor protein and BACE1. In conjunction with cGMP's ability to oppose neuron apoptosis, these effects suggest that high-dose biotin might have potential for the prevention and management of AD. cGMP also promotes neurogenesis, and may lessen stroke risk by impeding atherogenesis and hypertrophic remodeling in the cerebral vasculature. The neuroprotective potential of high-dose biotin likely could be boosted by concurrent administration of brain

  15. Performance of thermoluminescent materials for high dose dosimetry

    International Nuclear Information System (INIS)

    Texeira, Maria I.; Cecatti, Sonia G.P.; Caldas, Linda V.E.

    2008-01-01

    Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. The reproducibility, the lower detection limits and dose-response curves were obtained for all three materials. The different kinds of detectors show usefulness for dosimetry of workers exposed accidentally to high doses. (author)

  16. Immune reactivity after high-dose irradiation

    International Nuclear Information System (INIS)

    Gassmann, W.; Wottge, H.U.; von Kolzynski, M.; Mueller-Ruchholtz, W.

    1986-01-01

    Immune reactivity after total-body irradiation was investigated in rats using skin graft rejection as the indicator system. After sublethal irradiation with 10.5 Gy (approximately 50% lethality/6 weeks) the rejection of major histocompatibility complex allogeneic skin grafts was delayed significantly compared with nonirradiated control animals (28 versus 6.5 days). In contrast, skin grafts were rejected after 7.5 days in sublethally irradiated animals and 7 days in lethally irradiated animals if additional skin donor type alloantigens--namely, irradiated bone marrow cells--were given i.v. either simultaneously or with a delay of not more than 24 hr after the above conditioning regimen. These reactions were alloantigen-specific. They were observed in six different strain combinations with varying donors and recipients. Starting on day 2 after irradiation, i.v. injection of bone marrow gradually lost its effectivity and skin grafts were no longer rejected with uniform rapidity; skin donor marrow given on days 4 or 8 did not accelerate skin graft rejection at all. These data show that for approximately 1-2 days after high-dose total-body irradiation rats are still capable of starting a vigorous immune reaction against i.v.-injected alloantigens. The phenomenon of impaired rejection of skin grafted immediately after high-dose irradiation appears to result from the poor accessibility of skin graft alloantigens during the early postirradiation phase when vascularization of the grafted skin is insufficient

  17. High-dose vitamin C and cancer

    Directory of Open Access Journals (Sweden)

    Ahmet Unlu, M.D.

    2016-01-01

    Full Text Available Vitamin C (ascorbic acid, ascorbate is a basic compound that is of great importance with its role in various enzymatic reactions including the synthesis of collagen, as well as with its redox functions. Vitamin C has become the center of interest in cancer studies, in consequence of the facts that connective tissue changes and vitamin C deficiency were first alleged to be associated with cancer in the 1950s; and that high doses of vitamin C was asserted to be cytotoxic for cancer cells, later on. The results of the first study carried out in the 1970s were promising; but afterwards, the studies were ascertained to be faulty. Despite the positive results achieved from some laboratory and animal experiments, randomized clinical trials did not verify those findings, and no clear benefit of vitamin C for cancer treatment could be demonstrated. As for studies, where its use in combination with other cancer treatment regimens was assessed, conflicting results were obtained. Although intake of high doses of vitamin C is alleged to be harmless, based on that it is in the group of water soluble vitamins and is not stored in the body, there are many side effects and drug interactions reported in the literature. For now, it is better to abstain from this treatment, until the benefit of the treatment (if any is clearly demonstrated, considering the potential side effects and interactions.

  18. Comparison of Intravenous Morphine with Sublingual Buprenorphine in Management of Postoperative Pain after Closed Reduction Orthopedic Surgery

    Directory of Open Access Journals (Sweden)

    Ghasem Soltani

    2015-09-01

    Full Text Available Background: Postoperative pain is a common side effect following surgery that can significantly reduce surgical quality and patient’s satisfaction. Treatment options are morphine and buprenorphine. We aimed to compare the efficacy of a single dose of intravenous morphine with sublingual buprenorphine in postoperative pain control following closed reduction surgery. Methods: This triple blind clinical trial was conducted on 90 patients referred for closed reduction orthopedic surgery. They were older than 18 years and in classes I and II of the American Society of Anesthesiologists (ASA with an operation time of 30-90 minutes. Patients were divided into two groups of buprenorphine (4.5μg/kg sublingually and morphine (0.2mg/kg intravenously. Baseline characteristics, vital signs, pain score, level of sedation and pharmacological side effects were recorded in the recovery room (at 0 and 30 minutes, and in the ward (at 3, 6 and 12 hours. SPSS version 19 software was used for data analysis and the significance level was set at P Results: Ninety patients were studied, 60 males and 30 females with a mean age of 37.7±16.2 years. There was no significant difference between the two groups in terms of baseline characteristics.Pain score in the morphine group was significantly higher than the buprenorphine group with an average score of 2.5 (P

  19. Comparison of Intravenous Morphine with Sublingual Buprenorphine in Management of Postoperative Pain after Closed Reduction Orthopedic Surgery

    Directory of Open Access Journals (Sweden)

    Ghasem Soltani

    2015-10-01

    Full Text Available Background: Postoperative pain is a common side effect following surgery that can significantly reduce surgical quality and patient’s satisfaction. Treatment options are morphine and buprenorphine. We aimed to compare the efficacy of a single dose of intravenous morphine with sublingual buprenorphine in postoperative pain control following closed reduction surgery. Methods: This triple blind clinical trial was conducted on 90 patients referred for closed reduction orthopedic surgery. They were older than 18 years and in classes I and II of the American Society of Anesthesiologists (ASA with an operation time of 30-90 minutes. Patients were divided into two groups of buprenorphine (4.5μg/kg sublingually and morphine (0.2mg/kg intravenously. Baseline characteristics, vital signs, pain score, level of sedation and pharmacological side effects were recorded in the recovery room (at 0 and 30 minutes, and in the ward (at 3, 6 and 12 hours. SPSS version 19 software was used for data analysis and the significance level was set at P Results: Ninety patients were studied, 60 males and 30 females with a mean age of 37.7±16.2 years. There was no significant difference between the two groups in terms of baseline characteristics.Pain score in the morphine group was significantly higher than the buprenorphine group with an average score of 2.5 (P

  20. Buprenorphine/naloxone treatment practices in Malaysia: Results of national surveys of physicians and patients.

    Science.gov (United States)

    Vicknasingam, B; Dazali, M N M; Singh, D; Schottenfeld, R S; Chawarski, M C

    2015-07-01

    Medication assisted treatment with buprenorphine/naloxone (Bup/Nx), including prescribing and dispensing practices of general practitioners (GPs) in Malaysia and their patients' experiences with this treatment have not been systematically examined. The current study surveyed GPs providing Bup/Nx treatment and patients receiving office-based Bup/Nx treatment in Malaysia. Two cross-sectional surveys of GPs (N=115) providing outpatient Bup/Nx maintenance treatment and of patients (N=253) currently receiving Bup/Nx treatment throughout peninsular Malaysia. Physicians prescribed Bup/Nx dosages in the range of 2-4mg daily for 70% of patients and conducted urine testing in the past month on approximately 16% of their patients. In the patient survey, 79% reported taking daily Bup/Nx doses of 2mg or less; 82% reported that no urine toxicology testing had been conducted on them in the past month, 36% had an opiate positive urine test at the time of the survey, 43% reported illicit opiate use, 15% reported injection of heroin and 22% reported injection of Bup/Nx in the past month. Low daily Bup/Nx doses, lack of behavioral monitoring or counseling, and high rates of continued drug use, including injection of drugs and medications during Bup/Nx treatment in Malaysia, indicate continuing problems with implementation and less than optimal treatment effectiveness. High cost of Bup/Nx in Malaysia may deter patients from seeking treatment and contribute to taking low Bup/Nx dosages. Improved training of physicians and establishing standards for Bup/Nx dosing, routine toxicology testing, and counseling may be needed to improve care and treatment response. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  2. Chemical dosimetry principles in high dose dosimetry

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.

    2016-01-01

    In radiation processing, activities of principal concern are process validation and process control. The objective of such formalized procedures is to establish documentary evidence that the irradiation process has achieved the desired results. The key element of such activities is inevitably a well characterized reliable dosimetry system that is traceable to recognized national and international dosimetry standards. Only such dosimetry systems can help establish the required documentary evidence. In addition, industrial radiation processing such as irradiation of foodstuffs and sterilization of health careproducts are both highly regulated, in particular with regard to dose. Besides, dosimetry is necessary for scaling up processes from the research level to the industrial level. Thus, accurate dosimetry is indispensable

  3. Onyx as radiation detector for high doses

    International Nuclear Information System (INIS)

    Teixeira, Maria Inês; Souza, Divanizia N.; Caldas, Linda V.E.

    2011-01-01

    A study of the thermoluminescent (TL) characteristics of white, black and stripped onyx samples is reported in this work. Onyx is a variety of chalcedony, a form of quartz. The onyx stone is considered nobler than marble. The irradiations were performed using a Gamma-Cell 220 system ( 60 Co). The TL emission curves presented two peaks around 150 °C and 210 °C for all samples. The dose–response curves showed a sublinear behavior between 0.5 Gy and 5 kGy, and the lower detection limit for the white onyx pellets was 1.5 mGy. The main dosimetric characteristics were studied, and the material showed good performance for high dose dosimetry.

  4. The application of high dose food irradiation

    International Nuclear Information System (INIS)

    Bruyn, I. De

    1997-01-01

    During the 1950's to end 1970's the United States Army developed the basic methodology to produce shelf stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive 'dried cooked' taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 25 to 45 kGy (depending on the product) at a temperature of between -20 and -40 Centigrade to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions. The product can be guaranteed for more than two years as long as the integrity of the packaging is maintained. (Author)

  5. The application of high dose food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bruyn, I. De [Atomic Energy Corporation of South Africa LTD, Building 2000, P.O. Box 582, Pretoria 0001, (South Africa)

    1997-12-31

    During the 1950`s to end 1970`s the United States Army developed the basic methodology to produce shelf stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive `dried cooked` taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 25 to 45 kGy (depending on the product) at a temperature of between -20 and -40 Centigrade to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions. The product can be guaranteed for more than two years as long as the integrity of the packaging is maintained. (Author)

  6. Limitations of high dose carrier based formulations.

    Science.gov (United States)

    Yeung, Stewart; Traini, Daniela; Tweedie, Alan; Lewis, David; Church, Tanya; Young, Paul M

    2018-06-10

    This study was performed to investigate how increasing the active pharmaceutical ingredient (API) content within a formulation affects the dispersion of particles and the aerosol performance efficiency of a carrier based dry powder inhalable (DPI) formulation, using a custom dry powder inhaler (DPI) development rig. Five formulations with varying concentrations of API beclomethasone dipropionate (BDP) between 1% and 30% (w/w) were formulated as a multi-component carrier system containing coarse lactose and fine lactose with magnesium stearate. The morphology of the formulation and each component were investigated using scanning electron micrographs while the particle size was measured by laser diffraction. The aerosol performance, in terms of aerodynamic diameter, was assessed using the British pharmacopeia Apparatus E cascade impactor (Next generation impactor). Chemical analysis of the API was observed by high performance liquid chromatography (HPLC). Increasing the concentration of BDP in the blend resulted in increasing numbers and size of individual agglomerates and densely packed BDP multi-layers on the surface of the lactose carrier. BDP present within the multi-layer did not disperse as individual primary particles but as dense agglomerates, which led to a decrease in aerosol performance and increased percentage of BDP deposition within the Apparatus E induction port and pre-separator. As the BDP concentration in the blends increases, aerosol performance of the formulation decreases, in an inversely proportional manner. Concurrently, the percentage of API deposition in the induction port and pre-separator could also be linked to the amount of micronized particles (BDP and Micronized composite carrier) present in the formulation. The effect of such dose increase on the behaviour of aerosol dispersion was investigated to gain greater insight in the development and optimisation of higher dosed carrier-based formulations. Copyright © 2018 Elsevier B.V. All

  7. The introduction of buprenorphine-naloxone film in opioid substitution therapy in Australia: Uptake and issues arising from changing buprenorphine formulations.

    Science.gov (United States)

    Larance, Briony; Dietze, Paul; Ali, Robert; Lintzeris, Nicholas; White, Nancy; Jenkinson, Rebecca; Degenhardt, Louisa

    2015-11-01

    Buprenorphine-naloxone (BNX) film for opioid dependence treatment was introduced in Australia in 2011. A key difference in State policy approaches saw transfer from BNX tablets to BNX film mandated in South Australia (SA) with New South Wales (NSW) and Victoria (VIC) having less stringent policies. This study examined (i) how initiations and transfers were implemented, (ii) the profile and predictors of adverse effects as self-reported by BNX film clients, and (iii) dosing issues. Survey of 334 buprenorphine (BPN), BNX tablet and BNX film clients and semi-structured interviews with 39 key experts (KEs) in 2012. Comparisons are made between clients interviewed in SA versus NSW and VIC combined. Among the 180 current BNX film clients, 23% started treatment on BNX film, 18% requested a transfer to BNX film and 59% (n = 106) reported their clinic/prescriber recommended transfer to BNX film. Among clients who were offered but refused a transfer to BNX film (n = 66), the most common reason was 'I am happy with my current treatment and do not see a reason to change' (53%). Some opioid substitution therapy clients and KE viewed transfers as 'forced' (i.e. no choice of buprenorphine formulation). Multivariable regression showed residing in SA (vs. NSW/VIC) and a shorter length of current treatment episode were associated with more BNX film-attributed adverse effects but clinic/prescriber-recommended transfer was not. The introduction of BNX film in Australia varied across States. A perception of restricted choice in medication may have undermined initial acceptance in SA. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  8. Sedative and antinociceptive effects of dexmedetomidine and buprenorphine after oral transmucosal or intramuscular administration in cats.

    Science.gov (United States)

    Porters, Nathalie; Bosmans, Tim; Debille, Mariëlla; de Rooster, Hilde; Duchateau, Luc; Polis, Ingeborgh

    2014-01-01

    To compare sedation and antinociception after oral transmucosal (OTM) and intramuscular (IM) administration of a dexmedetomidine-buprenorphine combination in healthy adult cats. Randomized, 'blinded' crossover study, with 1 month washout between treatments. Six healthy neutered female cats, weighing 5.3-7.5 kg. A combination of dexmedetomidine (40 μg kg(-1) ) and buprenorphine (20 μg kg(-1) ) was administered by either the OTM (buccal cavity) or IM (quadriceps muscle) route. Sedation was measured using a numerical rating scale, at baseline and at various time points until 6 hours after treatment. At the same time points, analgesia was scored using a dynamic and interactive visual analogue scale, based on the response to an ear pinch, and by the cat's response to a mechanical stimulus exerted by a pressure rate onset device. Physiological and adverse effects were recorded, and oral pH measured. Signed rank tests were performed, with significance set at p < 0.05. Data are presented as median and range. There were no differences in sedation or antinociception scores between OTM and IM dosing at any of the time points. Nociceptive thresholds increased after both treatments but without significant difference between groups. Buccal pH remained between 8 and 8.5. Salivation was noted after OTM administration (n = 2) and vomiting after both OTM (n = 4), and IM (n = 3) dosing. In healthy adult cats, OTM administration of dexmedetomidine and buprenorphine resulted in comparable levels of sedation and antinociception to IM dosing. The OTM administration may offer an alternative route to administer this sedative-analgesic combination in cats. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  9. HIV-gp120 and physical dependence to buprenorphine.

    Science.gov (United States)

    Palma, J; Abood, M E; Benamar, K

    2015-05-01

    Opioids are among the most effective and commonly used analgesics in clinical practice for severe pain. However, the use of opioid medications is clinically limited by several adverse properties including dependence. While opioid dependence is a complex health condition, the treatment of HIV-infected individuals with opioid dependence presents additional challenges. The goal of this study was to examine the physical dependence to buprenorphine in the context of HIV. Young adult male rats (Sprague-Dawley) were pretreated with HIV-1 envelope glycoprotein 120 (gp120) injected into the periaqueductal gray area (PAG) and we examined the impact on physical dependence to opioid. It was found that the physical dependence to methadone occurred earlier than that to buprenorphine, and that gp120 did not enhance or precipitate the buprenorphine withdrawal. The results suggest that buprenorphine could be the better therapeutic option to manage opioid dependence in HIV. Copyright © 2015. Published by Elsevier Ireland Ltd.

  10. ELDRS Characterization for a Very High Dose Mission

    Science.gov (United States)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  11. Association between the DRD2 A1 allele and response to methadone and buprenorphine maintenance treatments.

    Science.gov (United States)

    Barratt, Daniel T; Coller, Janet K; Somogyi, Andrew A

    2006-06-05

    The TaqI A polymorphism (A(1)) of the dopamine D(2) receptor gene (DRD2), although not a specific predictor of opioid dependence, has been strongly associated with high levels of prior heroin use and poor treatment outcomes among methadone maintenance patients. The aims of this study were to confirm these findings via a retrospective analysis of A(1) allele frequency in methadone (n = 46) and buprenorphine (n = 25) patients, and non-opioid-dependent controls (n = 95). Subjects were genotyped at the DRD2 TaqI A locus using PCR amplification followed by TaqI restriction enzyme digestion and gel electrophoresis. For methadone and buprenorphine subjects, heroin use (prior to treatment), treatment outcomes, and withdrawal occurrence were determined from comprehensive case notes. No significant differences in A(1) allele frequency (%) were observed between: methadone (19.6%), buprenorphine (18.0%), and control (17.9%) groups (P > 0.7); successful and poor treatment outcome groups, methadone: 20.0% and 19.2%, respectively (P = 1.0); buprenorphine: 18.4% and 20.0%, respectively (P = 1.0). Also, there were no significant relationships between TaqI A genotype and prior heroin use (P = 0.47). However, among the successful methadone subjects, significantly fewer A(1) allele carriers experienced withdrawal than non-A(1) carriers (P = 0.04). In conclusion, the DRD2 genotype effects did not affect opioid maintenance treatment outcomes. This suggests the need for a further prospective investigation into the role of the DRD2 A(1) allele in heroin use and response to maintenance pharmacotherapies for opioid dependence.

  12. Influence of detomidine and buprenorphine on motor-evoked potentials in horses.

    Science.gov (United States)

    Nollet, H; Van Ham, L; Gasthuys, F; Dewulf, J; Vanderstraeten, G; Deprez, P

    2003-04-26

    Horses need to be sedated before they are investigated by transcranial magnetic stimulation because of the mild discomfort induced by the evoked muscle contraction and the noise of stimulation. This paper describes the influence of a combination of detomidine (10 microg/kg bodyweight) and a low dose of buprenorphine (2.4 microg/kg) on the onset latency and peak-to-peak amplitude of magnetic motor-evoked potentials in normal horses. There were no significant differences between measurements of these parameters made before the horses were sedated and measurements made 10 and 30 minutes after the drugs were administered.

  13. The antinociceptive efficacy of buprenorphine administered through the drinking water of rats

    DEFF Research Database (Denmark)

    Jessen, L; Bjerrum, Ole Jannik; Christensen, Sten

    2007-01-01

    was assessed by use of an analgesiometric model measuring the rats' latency time to withdrawal from a noxious heat stimulus applied to the plantar surface of the paw. Results revealed that buprenorphine in drinking water (0.056 mg/mL) induced significant increases in paw withdrawal latency times during a three...... water may be a viable treatment option for the relief of pain in laboratory rats, but at the doses used in this study in pain-free rats it was associated with a decrease in water intake and some behavioural changes....

  14. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  15. High dose potassium-nitrate chemical dosimeter

    International Nuclear Information System (INIS)

    Dorda de Cancio, E.M.; Munoz, S.S.

    1982-01-01

    This dosimeter is used to control 10 kGY-order doses (1 Mrad). Nitrate suffers a radiolitic reduction phenomena, which is related to the given dose. The method to use potassium nitrate as dosimeter is described, as well as effects of the temperature of irradiation, pH, nitrate concentration and post-irradiation stability. Nitrate powder was irradiated at a Semi-Industrial Plant, at Centro Atomico Ezeiza, and also in a Gammacell-220 irradiator. The dose rates used were 2,60 and 1,80 KGY/hour, and the given doses varied between 1,0 and 150 KGY. The uncertainty was +-3% in all the range. (author) [es

  16. Buprenorphine-naloxone therapy in pain management.

    Science.gov (United States)

    Chen, Kelly Yan; Chen, Lucy; Mao, Jianren

    2014-05-01

    Buprenorphine-naloxone (bup/nal in 4:1 ratio; Suboxone; Reckitt Benckiser Pharmaceuticals Incorporation, Richmond, VA) is approved by the Food and Drug Administration for outpatient office-based addiction treatment. In the past few years, bup/nal has been increasingly prescribed off-label for chronic pain management. The current data suggest that bup/nal may provide pain relief in patients with chronic pain with opioid dependence or addiction. However, the unique pharmacological profile of bup/nal confers it to be a weak analgesic that is unlikely to provide adequate pain relief for patients without opioid dependence or addiction. Possible mechanisms of pain relief by bup/nal therapy in opioid-dependent patients with chronic pain may include reversal of opioid-induced hyperalgesia and improvement in opioid tolerance and addiction. Additional studies are needed to assess the implication of bup/nal therapy in clinical anesthesia and perioperative pain management.

  17. Management of eight labor and delivery patients dependent on buprenorphine (Subutex™: A retrospective chart review [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Solina Tith

    2018-02-01

    Full Text Available Background: Opioid use during pregnancy is a growing concern in the United States. Buprenorphine has been recommended by “The American College of Obstetrics and Gynecology” as an alternative to methadone to decrease risks associated with the use of illicit opioids during pregnancy. The partial μ-opioid agonists’ unique pharmacology, including its long half time and high affinity to the μ-opioid receptor, complicates patient management in a highly kinetic, and often urgent field like obstetric anesthesia. We reviewed our management and outcomes in this medically complex population. Methods: An Institutional Review Board (IRB approved retrospective chart review was conducted of women admitted to the University of Washington Medical Center Labor and Delivery unit from July 2012 to November 2013 using buprenorphine. All deliveries, including intrauterine fetal demise, were included. Results: Eight women were admitted during this period to our L&D floor on buprenorphine. All required peri-partum anesthetic management either for labor and/or cesarean delivery management. Analgesic management included dilaudid or fentanyl PCA and/or continued epidural infusion, and in one instance ketamine infusion, while the pre-admission buprenorphine regimen was continued. Five babies were viable, two women experienced intrauterine fetal death at 22 and 36 weeks gestational age (GSA, respectively, and one neonate died shortly after delivery due to a congenital diaphragmatic hernia. Conclusions: This case series illuminates the medical complexity of parturients using buprenorphine. Different treatment modalities in the absence of evidence-based guidelines included additional opioid administration and continued epidural analgesia. The management of post-cesarean pain in patients on partial μ-opioid agonists remains complex and variable, and evidence-based guidelines could be useful for clinicians to direct care.

  18. Psychiatric comorbidity, red flag behaviors, and associated outcomes among office-based buprenorphine patients following Hurricane Sandy.

    Science.gov (United States)

    Williams, Arthur R; Tofighi, Babak; Rotrosen, John; Lee, Joshua D; Grossman, Ellie

    2014-04-01

    supply disruption, (3) a pre-storm history of red flag behaviors (in particular, repeat opioid-positive urines), and (4) new-onset post-storm psychiatric symptoms. Our findings highlight the relative resilience of buprenorphine as an office-based treatment modality for patients encountering a disaster with associated unanticipated service disruption. In responding to future disasters, triaging patient contact and priority based on a history of red-flag behaviors, rather than a history of psychiatric comorbidity, will likely optimize resource allocation, especially among recently enrolled patients. Additionally, patients endorsing new-onset psychiatric manifestations following disasters may be an especially high-risk group for poor outcomes, warranting further study.

  19. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  20. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  1. High dose radiotherapy for pituitary tumours

    International Nuclear Information System (INIS)

    Mead, K.W.

    1981-01-01

    The results of treatment of 120 pituitary tumours are presented. Based on this experience operable chromophobe adenomas are now treated with 5,000 rads in 4 weeks and inoperable ones receive an additional central dose to 7,500 rads. Pituitary Cushing's tumours are given 10,000 rads in 5 weeks using small fields and acromegalics 5,000 rads to the whole sella and 7,500 to its lower half. The absence of complications at these dose levels is attributed to the use of small fields and the precise application of treatment

  2. High dose radiotherapy for pituitary tumours

    Energy Technology Data Exchange (ETDEWEB)

    Mead, K.W. (Queensland Radium Inst., Herston (Australia))

    1981-11-01

    The results of treatment of 120 pituitary tumours are presented. Based on this experience operable chromophobe adenomas are now treated with 5,000 rads in 4 weeks and inoperable ones receive an additional central dose to 7,500 rads. Pituitary Cushing's tumours are given 10,000 rads in 5 weeks using small fields and acromegalics 5,000 rads to the whole sella and 7,500 to its lower half. The absence of complications at these dose levels is attributed to the use of small fields and the precise application of treatment.

  3. The effect of voluntarily ingested buprenorphine on rats subjected to surgically induced global cerebral ischaemia

    DEFF Research Database (Denmark)

    Kalliokoski, Otto Henrik; Abelson, Klas; Koch, Janne

    2010-01-01

    in buprenorphine-treated and untreated animals. A part from a slightly higher hyperthermia immediately after surgery and typical opiate-associated behaviour, the buprenorphine treatment had no apparent adverse effects on the experimental model. In contrast, the analgesic treatment improved the model by minimizing......The effect of perioperatively administered buprenorphine analgesia on rats subjected to surgically induced global ischaemia was assessed. Rats supplied with buprenorphine, mixed in nut paste for voluntary ingestion, displayed significant reductions in postoperative excretions of faecal...

  4. Population pharmacokinetics of buprenorphine following a two-stage intravenous infusion in healthy volunteers

    DEFF Research Database (Denmark)

    Jensen, Mette Lykke; Foster, David J.R.; Upton, Richard N.

    2007-01-01

    The aim of this investigation was to characterize the pharmacokinetics of buprenorphine following administration of an intravenous (i.v.) infusion. To date, the population kinetics of buprenorphine has been described for bolus administration only.......The aim of this investigation was to characterize the pharmacokinetics of buprenorphine following administration of an intravenous (i.v.) infusion. To date, the population kinetics of buprenorphine has been described for bolus administration only....

  5. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  6. High dose rate brachytherapy in treatment of high grade astrocytomas

    International Nuclear Information System (INIS)

    Garcia-Alejo, R.; Delgado, J.M.; Cerro, E. del; Torres, J.J.; Martinez, R.

    1996-01-01

    From May 1994 to June 1995, 18 patients with high grade astrocytomas were entered prospectively on a selective protocol combining surgery, external beam radiotherapy, stereotactic interstitial implantation with HDR Iridium 192 and chemotherapy. Only those patients with tumor size 100cc or less average dimension, high grade astrocytoma, Karnofsky 70 or greater, unilateral, circumscribed, unifocal, tumor stable or responding to external radiation and supratentorial were included in the study. Ages ranged from 16 to 69 years. There were 13 males and 5 females. Surgery consisted of biopsy only in 3 patients, subtotal resection in 11, and gross total resection in 4 patients. Focal external beam radiation portals included the contrast enhancing mass on CT scan plus a 3 cm margin. The protocol called for minimum tumor dose of 60 Gy to be given in 2 Gy daily fractions. An interstitial brachytherapy boost was to be performed two weeks after the conclusion of external beam radiation. The dose was 30 Gy in 4 fractions. The authors analyze on basis on their personal experience, the possibilities and the limits offered by this therapeutic procedure in neuro-oncology. Using stereotactic techniques, interstitial brachytherapy of brain tumors was technically possible with negligible acute morbidity and mortality, and appeared to be effective and may provide for an increase in tumor control in selected cases

  7. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  8. Dosimetry in high dose rate endoluminal brachytherapy

    International Nuclear Information System (INIS)

    Uno, Takashi; Kotaka, Kikuo; Itami, Jun

    1994-01-01

    In endoluminal brachytherapy for the tracheobronchial tree, esophagus, and bile duct, a reference point for dose calculation has been often settled at 1 cm outside from the middle of source travel path. In the current study, a change in the ratio of the reference point dose on the convex to concave side (Dq/Dp) was calculated, provided the source travel path bends as is the case in most endoluminal brachytherapies. Point source was presumed to move stepwise at 1 cm interval from 4 to 13 locations. Retention time at each location was calculated by personal computer so as to deliver equal dose at 1 cm from the linear travel path. With the retention time remaining constant, the change of Dq/Dp was assessed by bending the source travel path. Results indicated that the length of the source travel path and radius of its curve influenced the pattern of change in Dq/Dp. Therefore, it was concluded that the difference in reference dose on the convex and concave side of the curved path is not negligible under certain conditions in endoluminal brachytherapy. In order to maintain the ratio more than 0.9, relatively greater radius was required when the source travel path was decreased. (author)

  9. Cutaneous dosimetry at low and high dose

    International Nuclear Information System (INIS)

    Martin, M.

    2009-01-01

    As radiodermatitis is a complication related to the exposure to ionizing radiation after an accidental exposition or a medical examination (radiotherapy or interventional radiology), the author briefly reports an investigation of the response of the human keratinocyte to irradiation for different dose levels, and the search for exposure markers

  10. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  11. Preemptive Epidural Analgesia for Postoperative Pain Relief Revisited: Comparison of Combination of Buprenorphine and Neostigmine with Combination of Buprenorphine and Ketamine in Lower Abdominal Surgeries, A Double-blind Randomized Trial.

    Science.gov (United States)

    Choubey, Sanjay; Singh, Raj Bahadur

    2017-01-01

    Postoperative pain relief provides subjective comfort to patient in addition to blunting of autonomic and somatic reflex responses to pain, subsequently enhancing restoration of function by allowing the patient to breathe, cough, and move easily. The aim is to evaluate and compare the effects of neostigmine + buprenorphine and ketamine + buprenorphine for preemptive epidural analgesia for postoperative pain relief in patients undergoing abdominal surgeries under general anesthesia (GA). A double-blind randomized trial. A total of 60 American Society of Anesthesiologists physical status Classes I and II patients undergoing abdominal surgeries under GA were taken up for the study. They were randomly allocated into two groups, Group A and Group B of thirty patients each. Preemptive epidural analgesia for postoperative pain relief was provided by a combination of neostigmine 1 μg/kg + buprenorphine 2 μg/kg in Group A patients and ketamine 1 mg/kg + buprenorphine 2 μg/kg in Group B patients after induction of GA but before surgical incision. Postoperatively, vital parameters, pain score, requirement of top up doses, and side effects in the two groups were observed and recorded at 2, 4, 6, 10, 18, and 22 h. Mean values within each of the Group A and Group B were compared using one-way analysis of variance (one-way ANOVA). Mean values between Group A and Group B were compared using double analysis of variance (two-way ANOVA). Group A patients had a significant analgesia (visual analog scale [VAS] pain scores reduced significantly from 54.6 ± 6.3 at 2 h to 8.1 ± 8.9 at 22 h postoperatively). Group B patients had significant analgesia too (VAS pain scores reduced significantly from 36 ± 12.5 at 2 h to 5.3 ± 10.9 at 22 h postoperatively). There was however no significant difference between the two groups with respect to the degree of postoperative analgesia on comparison of VAS scores, effect on vital parameters, and incidence of side effects. Either of the two

  12. Impact of opioid therapy on gonadal hormones: focus on buprenorphine.

    Science.gov (United States)

    Varma, Anjali; Sapra, Mamta; Iranmanesh, Ali

    2018-02-17

    Objective The USA is in the midst of an opioid crisis. Understanding the impact of opioids and commonly used treatments for opioid dependence is essential for clinicians and researchers in order to educate and treat the nation's growing population with opioid use disorders. As a relatively new treatment for opioid dependence, buprenorphine is gaining popularity to the extent of becoming not only a preferred approach to the maintenance of opiate addiction, but also an option for chronic pain management. The purpose of this report is to review the available evidence on the endocrine effects of buprenorphine, particularly as it relates to the hypothalamic-pituitary-gonadal (HPG) axis, which is controversial and not fully defined. Method We conducted a Pubmed search (2000-2017) for human studies in the English language for articles that were available as full length regarding buprenorphine, endocrinopathy, hypogonadism, bone density, opioids. Case reports were also reviewed, although prospective studies and randomized controlled trials received more weight. Results Opioid induced hypogonadism is well established. Most studies report that buprenorphine being a partial agonist/antagonist may not be impacting the pituitary trophic hormones as much. There are reports of sexual dysfunction in subjects maintained on buprenorphine, some without hormonal correlation. Thus with the understanding that pertinent clinical studies are limited in number, varied in methodology, mostly cross sectional, predominantly in men and small number of participants, more research in this area is warranted. Conclusion Based on a comprehensive review of the available literature, we conclude that despite its increasing popularity, buprenorphine has not been adequately studied in respect to its long-term effects on the hypothalamic-pituitary-adrenal (HPA) axis. There is a great need for longitudinal systematic trials to define the potential buprenorphine-induced endocrine consequences.

  13. Statistical behavior of high doses in medical radiodiagnosis; Comportamento estatistico das altas doses em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana Elisa, E-mail: adrianaebarboza@gmail.com, E-mail: elisa@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  14. measurement of high dose radiation using yellow perspex dosimeter

    International Nuclear Information System (INIS)

    Thamrin, M Thoyib; Sofyan, Hasnel

    1996-01-01

    Measurement of high dose radiation using yellow perspex dosemeter has been carried out. Dose range used was between 0.1 to 3.0 kGy. Measurement of dose rate against Fricke dosemeter as a standard dose meter From the irradiation of Fricke dosemeter with time variation of 3,6,9,12,15 and 18 minute, it was obtained average dose rate of 955.57 Gy/hour, linear equation of dose was Y= 2.333+15.776 X with its correlation factor r = 0.9999. Measurement result using yellow perspex show that correlation between net optical density and radiation dose was not linear with its equation was ODc exp. [Bo + In(dose).Bi] Value of Bo = -0.215 and Bi=0.5020. From the experiment it was suggested that routine dosimeter (yellow perspex) should be calibrated formerly against standard dosemeters

  15. Methodology of high dose research in medical radiodiagnostic

    International Nuclear Information System (INIS)

    Barboza, Adriana E.; Martins, Cintia P. de S.

    2013-01-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations

  16. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  17. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  18. High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Was, Gary; Wirth, Brian; Motta, Athur; Morgan, Dane; Kaoumi, Djamel; Hosemann, Peter; Odette, Robert

    2018-04-30

    Project Objective: The objective of this proposal is to demonstrate the capability to predict the evolution of microstructure and properties of structural materials in-reactor and at high doses, using ion irradiation as a surrogate for reactor irradiations. “Properties” includes both physical properties (irradiated microstructure) and the mechanical properties of the material. Demonstration of the capability to predict properties has two components. One is ion irradiation of a set of alloys to yield an irradiated microstructure and corresponding mechanical behavior that are substantially the same as results from neutron exposure in the appropriate reactor environment. Second is the capability to predict the irradiated microstructure and corresponding mechanical behavior on the basis of improved models, validated against both ion and reactor irradiations and verified against ion irradiations. Taken together, achievement of these objectives will yield an enhanced capability for simulating the behavior of materials in reactor irradiations

  19. An evaluation of high-dose jobs for ALARA improvement

    International Nuclear Information System (INIS)

    Mun, J. H.; Kim, H. S.

    1997-01-01

    It is well known that about 70 percent of occupational dose have incurred from maintenance jobs at outage period. To reduce occupational dose, first, the high-dose jobs at the outage period should be identified and evaluated. For this, the database program is used, which contains the ORE data of reference plants, Kori Units 3 and 4. As a result, it is found that the jobs related to steam generator are the highest dose jobs in terms of collective ORE dose. From the analysis of the job procedures of those jobs, the ALARA improvements are also derived

  20. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  1. Embolic stroke associated with injection of buprenorphine tablets.

    Science.gov (United States)

    Lim, C C Tchoyoson; Lee, Sze Haur; Wong, Yee-Choon; Hui, Francis

    2009-09-15

    Drug users who crush, dissolve, and inject buprenorphine tablets parenterally may be at risk of severe thromboembolic complications or death. We describe patients with neurologic complications after injecting buprenorphine tablets. Brain MRI including diffusion-weighted imaging (DWI) in patients admitted to the neurologic department after injecting buprenorphine tablets were reviewed. Seven men had neurologic complications after buprenorphine tablet injection. In 5 patients, multiple small scattered hyperintense lesions were detected on DWI in the cortex, white matter, and basal ganglia of the cerebral hemisphere; one patient had a single small lesion. The side of MRI abnormality corresponded to the side of needle marks on the neck except in one patient who had bilateral injections. One patient, who denied injecting into the neck, had DWI abnormalities in the middle cerebral artery territory on one side and occlusion of the ipsilateral internal carotid artery. Buprenorphine tablets can be intentionally or inadvertently injected into the carotid artery, causing a characteristic appearance on diffusion-weighted imaging, consistent with embolic cerebral infarction.

  2. Acute renal failure in high dose carboplatin chemotherapy

    NARCIS (Netherlands)

    Frenkel, J.; Kool, G.; de Kraker, J.

    1995-01-01

    Carboplatin has been reported to cause acute renal failure when administered in high doses to adult patients. We report a 4 1/2-year-old girl who was treated with high-dose carboplatin for metastatic parameningeal embryonal rhabdomyosarcoma. Acute renal failure developed followed by a slow partial

  3. Pharmacogenetics and Pharmacokinetics in high-dose alkylating chemotherapy

    NARCIS (Netherlands)

    Ekhart, G.C. (Corine)

    2008-01-01

    High-dose chemotherapy in combination with peripheral blood progenitor cell transplantation has been developed as a possible curative treatment modality in several solid tumours. A frequently used high-dose regimen in the Netherlands is the CTC regimen, which is a 4-day course of cyclophosphamide,

  4. Fertility of Tall Girls Treated with High-Dose Estrogen, a Dose-Response Relationship

    NARCIS (Netherlands)

    Hendriks, A. E. J.; Drop, S. L. S.; Laven, J. S. E.; Boot, A. M.

    Context: High-dose estrogen treatment to reduce final height of tall girls increases their risk for infertility in later life. Objective: The aim was to study the effect of estrogen dose on fertility outcome of these women. Design/Setting: We conducted a retrospective cohort study of university

  5. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  6. Inhibition of CYP2D6-mediated tramadol O-demethylation in methadone but not buprenorphine maintenance patients.

    Science.gov (United States)

    Coller, Janet K; Michalakas, Jennifer R; James, Heather M; Farquharson, Aaron L; Colvill, Joel; White, Jason M; Somogyi, Andrew A

    2012-11-01

    Management of pain in opioid dependent individuals is problematic due to numerous issues including cross-tolerance to opioids. Hence there is a need to find alternative analgesics to classical opioids and tramadol is potentially one such alternative. Methadone inhibits CYP2D6 in vivo and in vitro. We aimed to investigate the effect of methadone on the pathways of tramadol metabolism: O-demethylation (CYP2D6) to the opioid-active metabolite M1 and N-demethylation (CYP3A4) to M2 in subjects maintained on methadone or buprenorphine as a control. Compared with subjects on buprenorphine, methadone reduced the clearance of tramadol to active O-desmethyl-tramadol (M1) but had no effect on N-desmethyltramadol (M2) formation. Similar to other analgesics whose active metabolites are formed by CYP2D6 such as codeine, reduced formation of O-desmethyltramadol (M1) is likely to result in reduced analgesia for subjects maintained on methadone. Hence alternative analgesics whose metabolism is independent of CYP2D6 should be utilized in this patient population. To compare the O- (CYP2D6 mediated) and N- (CYP3A4 mediated) demethylation metabolism of tramadol between methadone and buprenorphine maintained CYP2D6 extensive metabolizer subjects. METHODS Nine methadone and seven buprenorphine maintained subjects received a single 100 mg dose of tramadol hydrochloride. Blood was collected at 4 h and assayed for tramadol, methadone, buprenorphine and norbuprenorphine (where appropriate) and all urine over 4 h was assayed for tramadol and its M1 and M2 metabolites. The urinary metabolic ratio [median (range)] for O-demethylation (M1) was significantly lower (P= 0.0002, probability score 1.0) in the subjects taking methadone [0.071 (0.012-0.103)] compared with those taking buprenorphine [0.192 (0.108-0.392)], but there was no significant difference (P= 0.21, probability score 0.69) in N-demethylation (M2). The percentage of dose [median (range)] recovered as M1 was significantly lower

  7. Statistical behavior of high doses in medical radiodiagnosis

    International Nuclear Information System (INIS)

    Barboza, Adriana Elisa

    2014-01-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  8. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  9. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  10. Assessment of the sedative effects of buprenorphine administered with 10 μg/kg detomidine in horses.

    Science.gov (United States)

    Love, E J; Taylor, P M; Murrell, J; Whay, H R; Waterman-Pearson, A E

    2011-04-09

    The aim of this randomised, observer-blinded, crossover study was to compare the effects of six treatments, administered intravenously to six horses: saline and saline (S/S); detomidine and saline (D/S); detomidine and 5 µg/kg buprenorphine (D/B5); detomidine and 7.5 µg/kg buprenorphine (D/B7.5); detomidine and 10 µg/kg buprenorphine (D/B10); and detomidine and 25 µg/kg butorphanol (D/BUT). The detomidine dose was 10 µg/kg for all treatments in which it was included. Sedation was subjectively assessed and recorded on a visual analogue scale. Peak sedation, duration of sedation and the area under the curve (AUC) for sedation scores were investigated using a univariate general linear model with post-hoc Tukey tests (P<0.05). Peak sedation and duration of sedation were statistically significantly different between treatments (P<0.001). No sedation was apparent after administration of S/S. The AUC was significantly different between treatments (P=0.010), with S/S being significantly different from D/S, D/BUT, D/B5 and D/B7.5, but not D/B10 (P=0.051).

  11. Brain magnetic resonance imaging of infants exposed prenatally to buprenorphine

    International Nuclear Information System (INIS)

    Kahila, H.; Kivitie-Kallio, S.; Halmesmaki, E.; Valanne, L.; Autti, T.

    2007-01-01

    Purpose: To evaluate the brains of newborns exposed to buprenorphine prenatally. Material and Methods: Seven neonates followed up antenatally in connection with their mothers' buprenorphine replacement therapy underwent 1.5T magnetic resonance imaging (MRI) of the brain before the age of 2 months. The infants were born to heavy drug abusers. Four mothers were hepatitis C positive, and all were HIV negative. All mothers smoked tobacco and used benzodiazepines. All pregnancies were full term, and no perinatal asphyxia occurred. All but one neonate had abstinence syndrome and needed morphine replacement therapy. Results: Neither structural abnormalities nor abnormalities in signal intensity were recorded. Conclusion: Buprenorphine replacement therapy does not seem to cause any major structural abnormalities of the brain, and it may prevent known hypoxic-ischemic brain changes resulting from uncontrolled drug abuse. Longitudinal studies are needed to assess possible abnormalities in the brain maturation process

  12. Brain magnetic resonance imaging of infants exposed prenatally to buprenorphine

    Energy Technology Data Exchange (ETDEWEB)

    Kahila, H.; Kivitie-Kallio, S.; Halmesmaki, E.; Valanne, L.; Autti, T. [Dept. of Obstetrics and Gynecology, Dept. of Pediatrics, and Helsinki Medical Imaging Center, Helsinki Univ. Central Hospital (Finland)

    2007-02-15

    Purpose: To evaluate the brains of newborns exposed to buprenorphine prenatally. Material and Methods: Seven neonates followed up antenatally in connection with their mothers' buprenorphine replacement therapy underwent 1.5T magnetic resonance imaging (MRI) of the brain before the age of 2 months. The infants were born to heavy drug abusers. Four mothers were hepatitis C positive, and all were HIV negative. All mothers smoked tobacco and used benzodiazepines. All pregnancies were full term, and no perinatal asphyxia occurred. All but one neonate had abstinence syndrome and needed morphine replacement therapy. Results: Neither structural abnormalities nor abnormalities in signal intensity were recorded. Conclusion: Buprenorphine replacement therapy does not seem to cause any major structural abnormalities of the brain, and it may prevent known hypoxic-ischemic brain changes resulting from uncontrolled drug abuse. Longitudinal studies are needed to assess possible abnormalities in the brain maturation process.

  13. Recidivism with opiate addicted patients on buprenorphine substitution treatment: Case report

    Directory of Open Access Journals (Sweden)

    Crnić Katarina B.

    2017-01-01

    Full Text Available Introduction: Opiate dependence is a serious, chronic and recurrent psychiatric disorder, whose prevalence reach epidemic proportions. This also contributes to a significant increase in mortality, associated with overdose with opiates, as well as the rise in other health and social problems of the society. The methods and availability of treatment do not correspond to increased treatment needs, and treatment success is limited by the characteristics of the disorder, or numerous risk factors, which contribute to a high percentage of recidivism. Good clinical practice guidelines have defined treatment recommendations that include high and low-demanding programs. The personalized and integrative approaches are emphasized. Case report: The patient aged 41 years, intravenous-use opiate addict from his adolescences, with numerous psychological, health and social complications of addiction, is a participant in institutional treatment, following a court order as a measure of obligatory treatment, due to criminal offenses related to addiction. The history of the disease refers to numerous unsuccessful attempts to heal and short-term abstinence in the past, mainly in penal institutions. The patient meets all the criteria defined by the guidelines for inclusion in the buprenorphine maintenance program started in the year 2013. During the four-year treatment, the doses of the drug were adapted as needed; two heroin relapses and many in-risk situations for relapse were registered. The treatment continued with close monitoring of the patient's condition and, with appropriate psychosocial interventions, contribute to keeping the patient in treatment and preventing the development of new complications of addiction, as well an improving the quality of his life. Discussion: Pharmacological treatment of opioid dependence relies on agents belonging to groups of antagonists, agonists and partial agonists of opiate receptors. The earlier programs with abstinence as a

  14. Opioid Addiction and Abuse in Primary Care Practice: A Comparison of Methadone and Buprenorphine as Treatment Options

    Science.gov (United States)

    Bonhomme, Jean; Shim, Ruth S.; Gooden, Richard; Tyus, Dawn; Rust, George

    2014-01-01

    Opioid abuse and addiction have increased in frequency in the United States over the past 20 years. In 2009, an estimated 5.3 million persons used opioid medications nonmedically within the past month, 200 000 used heroin, and approximately 9.6% of African Americans used an illicit drug. Racial and ethnic minorities experience disparities in availability and access to mental health care, including substance use disorders. Primary care practitioners are often called upon to differentiate between appropriate, medically indicated opioid use in pain management vs inappropriate abuse or addiction. Racial and ethnic minority populations tend to favor primary care treatment settings over specialty mental health settings. Recent therapeutic advances allow patients requiring specialized treatment for opioid abuse and addiction to be managed in primary care settings. The Drug Addiction Treatment Act of 2000 enables qualified physicians with readily available short-term training to treat opioid-dependent patients with buprenorphine in an office-based setting, potentially making primary care physicians active partners in the diagnosis and treatment of opioid use disorders. Methadone and buprenorphine are effective opioid replacement agents for maintenance and/or detoxification of opioid-addicted individuals. However, restrictive federal regulations and stigmatization of opioid addiction and treatment have limited the availability of methadone. The opioid partial agonist-antagonist buprenorphine/naloxone combination has proven an effective alternative. This article reviews the literature on differences between buprenorphine and methadone regarding availability, efficacy, safety, side-effects, and dosing, identifying resources for enhancing the effectiveness of medication-assisted recovery through coordination with behavioral/psychological counseling, embedded in the context of recovery-oriented systems of care. PMID:23092049

  15. Accelerated Irradiations for High Dose Microstructures in Fast Reactor Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhijie [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-31

    The objective of this project is to determine the extent to which high dose rate, self-ion irradiation can be used as an accelerated irradiation tool to understand microstructure evolution at high doses and temperatures relevant to advanced fast reactors. We will accomplish the goal by evaluating phase stability and swelling of F-M alloys relevant to SFR systems at very high dose by combining experiment and modeling in an effort to obtain a quantitative description of the processes at high and low damage rates.

  16. Radiobiological aspects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation

    International Nuclear Information System (INIS)

    Turesson, I.

    1990-01-01

    The biological effects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation in interstitial and intracavitary radiotherapy and total body irradiation are discussed in terms of dose-rate fractionation sensitivity for various tissues. A scaling between dose-rate and fraction size was established for acute and late normal-tissue effects which can serve as a guideline for local treatment in the range of dose rates between 0.02 and 0.005 Gy/min and fraction sizes between 8.5 and 2.5 Gy. This is valid provided cell-cycle progression and proliferation can be ignored. Assuming that the acute and late tissue responses are characterized by α/β values of about 10 and 3 Gy and a mono-exponential repair half-time of about 3 h, the same total doses given with either of the two methods are approximately equivalent. The equivalence for acute and late non-hemopoietic normal tissue damage is 0.02 Gy/min and 8.5 Gy per fraction; 0.01 Gy/min and 5.5 Gy per fraction; and 0.005 Gy/min and 2.5Gy per fraction. A very low dose rate, below 0.005 Gy/min, is thus necessary to simulate high dose-rate radiotherapy with fraction sizes of about 2Gy. The scaling factor is, however, dependent on the repair half-time of the tissue. A review of published data on dose-rate effects for normal tissue response showed a significantly stronger dose-rate dependence for late than for acute effects below 0.02 Gy/min. There was no significant difference in dose-rate dependence between various acute non-hemopoietic effects or between various late effects. The consistent dose-rate dependence, which justifies the use of a general scaling factor between fraction size and dose rate, contrasts with the wide range of values for repair half-time calculated for various normal-tissue effects. This indicates that the model currently used for repair kinetics is not satisfactory. There are also few experimental data in the clinical dose-rate range, below 0.02 Gy/min. It is therefore

  17. High-temperature absorbed dose measurements in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.; Ardonceau, J.; Zuppiroli, L.

    1988-01-01

    Organic conductors of the tetraselenotetracene family have been tested as ''high-temperature'' absorbed dose dosimeters. They were heated up to 120 0 C and irradiated at this temperature with 1-MeV electrons in order to simulate, in a short time, a much longer γ-ray irradiation. The electric resistance increase of the crystal can be considered a good measurement of the absorbed dose in the range 10 6 Gy to a few 10 8 Gy and presumably one order of magnitude more. This dosimeter also permits on-line (in-situ) measurements of the absorbed dose without removing the sensor from the irradiation site. The respective advantages of organic and inorganic dosimeters at these temperature and dose ranges are also discussed. In this connection, we outline new, but negative, results concerning the possible use of silica as a high-temperature, high-dose dosimeter. (author)

  18. Radiophotoluminescence light scope for high-dose dosimetry

    International Nuclear Information System (INIS)

    Sato, Fuminobu; Zushi, Naoki; Sakiyama, Tomoki; Kato, Yushi; Murata, Isao; Shimizu, Kikuo; Yamamoto, Takayoshi; Iida, Toshiyuki

    2015-01-01

    A radiophotoluminescence (RPL) light scope is a remote-sensing technique for measuring in situ the radiation dose in an RPL detector placed at a distance. The RPL light scope is mainly composed of an ultraviolet (UV) pulse laser, telescopic lenses, a photomultiplier tube, and camera modules. In a performance test, some RPL detectors were placed at distances up to 30 m and were illuminated with a pulsed UV laser beam. The photoluminescence responses of the RPL detectors were analyzed using this scope. Their radiation doses were determined from the amplitude of the given component of the photoluminescence responses. The RPL readout could be repeated without fading, and its amplitude exhibited good linearity at a dose ranging from 0.1 to 60 Gy. Furthermore, a two-dimensional distribution of radiation dose was obtained by laser scanning on an RPL detector. It was confirmed that the RPL light scope was a useful remote-sensing tool for high-dose dosimetry. - Highlights: • A radiophotoluminescence (RPL) light scope was developed for high-dose dosimetry. • The RPL light scope has high sensitivity and accuracy in high-dose dosimetry. • Two-dimensional radiation dose distribution was obtained by the RPL light scope.

  19. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with

  20. Predictors of long term opioid withdrawal outcome after short-term stabilization with buprenorphine.

    Science.gov (United States)

    Saleh, M I

    2014-01-01

    We aim to examine predictors of opiate abstinence status 3 months after the end of buprenorphine/naloxone treatment for opioid-dependent participants. Participants (n= 516, age > 15 years) received buprenorphine/ naloxone treatment for 4 weeks and then randomly assigned to undergo dose tapering over either 7 days or 28 days. Bivariate analysis was performed to identify possible predictors of successful opiate abstinence outome (p-value opioid and drug urine tests result at the end taper; employment status, family problems, and alcohol use domains of addiction severity index (ASI) score; and clinical opiate withdrawal scale (COWS) at the end of stabilization. Final predictor list identified by logistic regression include: ASI score for family and alcohol problems, COWS at the end of stabilization and opiate urine test at the end of taper. Participants presenting with a negative urine test for opiate, more severe alcohol, more severe family problems, or more symptoms of opiate withdrawal at the end of stabilization were more likely to have a successful opiate abstinence.

  1. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    International Nuclear Information System (INIS)

    Oliveira, Jetro Pereira de; Batista, Delano Valdivino Santos; Bardella, Lucia Helena; Carvalho, Arnaldo Rangel

    2009-01-01

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  2. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  3. High-dose dosimetry using natural silicate minerals

    International Nuclear Information System (INIS)

    Carmo, Lucas S. do; Mendes, Leticia; Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina; Barbosa, Renata F.

    2015-01-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  4. High-dose dosimetry using natural silicate minerals

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Mendes, Leticia, E-mail: isatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina, E-mail: lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear; Barbosa, Renata F., E-mail: profcelta@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil). Departamento de Ciencias do Mar

    2015-07-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  5. Treatment of the prostate cancer with high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Torres Silva, Felipe

    2002-01-01

    The prostate cancer treatment in early stages is controversial. The high dose rate brachytherapy has been used like monotherapy or boost with external beam radiotherapy in advanced disease. This paper describes the technique and the advantages over other modalities

  6. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    International Nuclear Information System (INIS)

    Cunha, Elisete L.; Schimitberger, Thiago

    2017-01-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm -1 and 3271 cm -1 , with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  7. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Elisete L.; Schimitberger, Thiago, E-mail: elisete.cunha@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Oliveira, Cristiana M.; Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm{sup -1} and 3271 cm{sup -1}, with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  8. Braquiterapia de alta taxa de dose no Brasil High-dose rate brachytherapy in Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2004-10-01

    Full Text Available A braquiterapia de alta taxa de dose foi introduzida em nosso meio em janeiro de 1991. Desde então, houve uma mudança significativa na abordagem das neoplasias malignas em relação às vantagens do novo método, e também resolução da demanda reprimida de braquiterapia para as neoplasias ginecológicas. Nos primeiros dez anos de atividade, o Brasil tratou, em 31 serviços, 26.436 pacientes com braquiterapia, sendo mais de 50% das pacientes portadoras de neoplasias do colo uterino. Este estudo mostra o número e o perfil de pacientes tratados com esse método e a sua distribuição no território nacional, deixando explícito o benefício da braquiterapia de alta taxa de dose para o Brasil.High-dose rate brachytherapy was first introduced in Brazil in January 1991. Significant changes in the management of malignant neoplasms were observed since utilization of high-dose rate brachytherapy. The high number of gynecological patients awaiting for brachytherapy also decreased during this period. In the first ten years 26,436 patients were treated with high-dose rate brachytherapy. More than 50% of these patients presented neoplasms of the uterine cervix. In this study we present the number and profile of the patients treated with high-dose rate brachytherapy as well as the distribution of these patients in the Brazilian territory, proving the benefit of the use of high-dose rate brachytherapy in Brazil.

  9. The relationship between diversion-related attitudes and sharing and selling buprenorphine.

    Science.gov (United States)

    Kenney, Shannon R; Anderson, Bradley J; Bailey, Genie L; Stein, Michael D

    2017-07-01

    Buprenorphine medication-assisted treatment (B-MAT) is an efficacious and popular outpatient treatment for opioid use disorder. However, the likelihood of buprenorphine diversion is a public health concern. We examined the relationship between attitudes toward diversion as predictors of both sharing and selling buprenorphine. Participants (n=476) were patients undergoing short-term inpatient opioid detoxification. Multinomial logistic regression was used to estimate the adjusted association of sharing and selling buprenorphine with demographics, substance use behaviors, and attitudes toward sharing and selling buprenorphine. Among the two hundred persons who had ever been prescribed buprenorphine (73.4% male, 89% heroin users), 50.5% reported they had shared buprenorphine and 28.0% reported they had sold buprenorphine. Controlling for other covariates, the odds of sharing buprenorphine were 3.17 (95% CI 1.21; 8.32) times higher for persons who agreed that it was "right to share buprenorphine with dope sick friends" than for those who did not agree with this attitude. Attitudes toward selling (OR 2.92; 95% CI 1.35; 6.21) and sharing (OR 4.12; 95% CI 1.64; 10.32) buprenorphine were the only significant correlates of selling, with the odds of selling exponentially greater among persons with favorable attitudes toward sharing or selling buprenorphine. Although considered diversion, sharing B-MAT is normative among B-MAT patients. Assessing B-MAT patients' attitudes about diversion may help identify patients requiring enhanced oversight, education, or intervention aimed at modifying attitudes to reduce their likelihood to share or sell buprenorphine. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Opiate withdrawal syndrome in buprenorphine abusers admitted to ...

    African Journals Online (AJOL)

    The sex v time interaction and the mode of consumption of buprenorphine had significant ... and cancer patients. .... The anal- ysis of the main simple effects revealed a significant ef- fect of time on withdrawal scores for both men (F=65.4,.

  11. The Implementation of Buprenorphine/Naloxone in College Health Practice

    Science.gov (United States)

    DeMaria, Peter A., Jr.; Patkar, Ashwin A.

    2008-01-01

    Opiate abuse and dependence have become important concerns for college healthcare providers. The passage of the Drug Addiction Treatment Act of 2000 and the approval of the combination buprenorphine/naloxone for office-based treatment of opiate dependence have increased the options available for college students and their healthcare providers. The…

  12. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  13. Proximity correction of high-dosed frame with PROXECCO

    Science.gov (United States)

    Eisenmann, Hans; Waas, Thomas; Hartmann, Hans

    1994-05-01

    Usefulness of electron beam lithography is strongly related to the efficiency and quality of methods used for proximity correction. This paper addresses the above issue by proposing an extension to the new proximity correction program PROXECCO. The combination of a framing step with PROXECCO produces a pattern with a very high edge accuracy and still allows usage of the fast correction procedure. Making a frame with a higher dose imitates a fine resolution correction where the coarse part is disregarded. So after handling the high resolution effect by means of framing, an additional coarse correction is still needed. Higher doses have a higher contribution to the proximity effect. This additional proximity effect is taken into account with the help of the multi-dose input of PROXECCO. The dose of the frame is variable, depending on the deposited energy coming from backscattering of the proximity. Simulation proves the very high edge accuracy of the applied method.

  14. Opioids and the management of chronic severe pain in the elderly: consensus statement of an International Expert Panel with focus on the six clinically most often used World Health Organization Step III opioids (buprenorphine, fentanyl, hydromorphone, methadone, morphine, oxycodone).

    Science.gov (United States)

    Pergolizzi, Joseph; Böger, Rainer H; Budd, Keith; Dahan, Albert; Erdine, Serdar; Hans, Guy; Kress, Hans-Georg; Langford, Richard; Likar, Rudolf; Raffa, Robert B; Sacerdote, Paola

    2008-01-01

    status need to be taken carefully into account when addressing pain in the elderly. World Health Organization step III opioids are the mainstay of pain treatment for cancer patients and morphine has been the most commonly used for decades. In general, high level evidence data (Ib or IIb) exist, although many studies have included only few patients. Based on these studies, all opioids are considered effective in cancer pain management (although parts of cancer pain are not or only partially opioid sensitive), but no well-designed specific studies in the elderly cancer patient are available. Of the 2 opioids that are available in transdermal formulation--fentanyl and buprenorphine--fentanyl is the most investigated, but based on the published data both seem to be effective, with low toxicity and good tolerability profiles, especially at low doses. 2. The use of opioids in noncancer-related pain: Evidence is growing that opioids are efficacious in noncancer pain (treatment data mostly level Ib or IIb), but need individual dose titration and consideration of the respective tolerability profiles. Again no specific studies in the elderly have been performed, but it can be concluded that opioids have shown efficacy in noncancer pain, which is often due to diseases typical for an elderly population. When it is not clear which drugs and which regimes are superior in terms of maintaining analgesic efficacy, the appropriate drug should be chosen based on safety and tolerability considerations. Evidence-based medicine, which has been incorporated into best clinical practice guidelines, should serve as a foundation for the decision-making processes in patient care; however, in practice, the art of medicine is realized when we individualize care to the patient. This strikes a balance between the evidence-based medicine and anecdotal experience. Factual recommendations and expert opinion both have a value when applying guidelines in clinical practice. 3. The use of opioids in

  15. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  16. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  17. Investigation of polymer composite for high dose dosimetry

    International Nuclear Information System (INIS)

    Pereira, E.L.M.; Batista, A.S.M.; Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H.

    2017-01-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO 2 ) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm -1 and 1730 cm -1 can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm -1 and 1730 cm -1 whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  18. Investigation of polymer composite for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, E.L.M.; Batista, A.S.M., E-mail: adriananuclear@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO{sub 2}) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm{sup -1} and 1730 cm{sup -1} can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm{sup -1} and 1730 cm{sup -1} whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  19. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  20. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  1. Establishment of a dosimetric system for high doses using glasses

    International Nuclear Information System (INIS)

    Correa Quezada, Valeria de la Asuncion

    1997-01-01

    A routine dosimetric system was developed using commercial glass samples. The dosimetric characteristics of national and imported samples were studied: batch uniformity, response repeatability, reutilization, absorbed dose response, detection range, response stability as a function of absorbed dose, storage temperature and thermal treatments pre- and post-irradiation, using the optical absorption technique. As an application, the dosimetric system was tested in a flower irradiation process at IPEN. All the obtained results show the usefulness of the proposed system for high dose dosimetry. (author)

  2. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  3. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  4. Interaction of 2-Gy Equivalent Dose and Margin Status in Perioperative High-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Martinez-Monge, Rafael; Cambeiro, Mauricio; Moreno, Marta; Gaztanaga, Miren; San Julian, Mikel; Alcalde, Juan; Jurado, Matias

    2011-01-01

    Purpose: To determine patient, tumor, and treatment factors predictive of local control (LC) in a series of patients treated with either perioperative high-dose-rate brachytherapy (PHDRB) alone (Group 1) or with PHDRB combined with external-beam radiotherapy (EBRT) (Group 2). Patient and Methods: Patients (n = 312) enrolled in several PHDRB prospective Phase I-II studies conducted at the Clinica Universidad de Navarra were analyzed. Treatment with PHDRB alone, mainly because of prior irradiation, was used in 126 patients to total doses of 32 Gy/8 b.i.d. or 40 Gy/10 b.i.d. treatments after R0 or R1 resections. Treatment with PHDRB plus EBRT was used in 186 patients to total doses of 16 Gy/4 b.i.d. or 24 Gy/6 b.i.d. treatments after R0 or R1 resections along with 45 Gy of EBRT with or without concomitant chemotherapy. Results: No dose-margin interaction was observed in Group 1 patients. In Group 2 patients there was a significant interaction between margin status and 2-Gy equivalent (Eq2Gy) dose (p = 0.002): (1) patients with negative margins had 9-year LC of 95.7% at Eq2Gy = 62.9Gy; (2) patients with close margins of >1 mm had 9-year LC of 92.4% at Eq2Gy = 72.2Gy, and (3) patients with positive/close <1-mm margins had 9-year LC of 68.0% at Eq2Gy = 72.2Gy. Conclusions: Two-gray equivalent doses ≥70 Gy may compensate the effect of close margins ≥1 mm but do not counterbalance the detrimental effect of unfavorable (positive/close <1 mm) resection margins. No dose-margin interaction is observed in patients treated at lower Eq2Gy doses ≤50 Gy with PHDRB alone.

  5. Calcium carbonate as a possible dosimeter for high irradiation doses

    International Nuclear Information System (INIS)

    Negron M, A.; Ramos B, S.; Camargo R, C.; Uribe, R. M.; Gomez V, V.; Kobayashi, K.

    2014-08-01

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  6. Calcium carbonate as a possible dosimeter for high irradiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Negron M, A.; Ramos B, S.; Camargo R, C. [UNAM, Instituto de Ciencias Nucleares, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Uribe, R. M. [Kent State University, College of Technology, Kent OH (United States); Gomez V, V. [UNAM, Instituto de Quimica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Kobayashi, K., E-mail: negron@nucleares.unam.mx [Yokohama National University (Japan)

    2014-08-15

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  7. Chromosomal Aberrations in Normal and AT Cells Exposed to High Dose of Low Dose Rate Irradiation

    Science.gov (United States)

    Kawata, T.; Shigematsu, N.; Kawaguchi, O.; Liu, C.; Furusawa, Y.; Hirayama, R.; George, K.; Cucinotta, F.

    2011-01-01

    Ataxia telangiectasia (A-T) is a human autosomally recessive syndrome characterized by cerebellar ataxia, telangiectases, immune dysfunction, and genomic instability, and high rate of cancer incidence. A-T cell lines are abnormally sensitive to agents that induce DNA double strand breaks, including ionizing radiation. The diverse clinical features in individuals affected by A-T and the complex cellular phenotypes are all linked to the functional inactivation of a single gene (AT mutated). It is well known that cells deficient in ATM show increased yields of both simple and complex chromosomal aberrations after high-dose-rate irradiation, but, less is known on how cells respond to low-dose-rate irradiation. It has been shown that AT cells contain a large number of unrejoined breaks after both low-dose-rate irradiation and high-dose-rate irradiation, however sensitivity for chromosomal aberrations at low-dose-rate are less often studied. To study how AT cells respond to low-dose-rate irradiation, we exposed confluent normal and AT fibroblast cells to up to 3 Gy of gamma-irradiation at a dose rate of 0.5 Gy/day and analyzed chromosomal aberrations in G0 using fusion PCC (Premature Chromosomal Condensation) technique. Giemsa staining showed that 1 Gy induces around 0.36 unrejoined fragments per cell in normal cells and around 1.35 fragments in AT cells, whereas 3Gy induces around 0.65 fragments in normal cells and around 3.3 fragments in AT cells. This result indicates that AT cells can rejoin breaks less effectively in G0 phase of the cell cycle? compared to normal cells. We also analyzed chromosomal exchanges in normal and AT cells after exposure to 3 Gy of low-dose-rate rays using a combination of G0 PCC and FISH techniques. Misrejoining was detected in the AT cells only? When cells irradiated with 3 Gy were subcultured and G2 chromosomal aberrations were analyzed using calyculin-A induced PCC technique, the yield of unrejoined breaks decreased in both normal and AT

  8. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  9. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  10. A novel theory of radiation damage at high doses

    International Nuclear Information System (INIS)

    Seeger, A.; Stuttgart Univ.

    1989-01-01

    Deviations of radiation damage (in the case of metals usually monitored by the residual electrical resistivity) from proportionality with the irradiation dose have so far been analysed almost exclusively in terms of extensions of models originally developed for small doses. The present theory considers the opposite limit i.e. the quasi-saturated state. It is argued that at high doses the Lueck-Sizmann effect may result in a self-organization of clusters of vacancies and self-interstitials, forming a heterogeneous froth. Possible structures of this froth and its effect on the electrical resistivity of metals are discussed. The model is shown to account for the dependence of the ''saturation resistivity'' on the nature of the irradiation as well as for several other hitherto poorly explained observations. Among them are the electrical-resistivity variation induced by high-dose irradiation with heavy ions, the amorphization of certain alloys by high-dose electron irradiation, and the occurrence of ordered arrays of stacking-fault tetrahedra after in-situ irradiations in high-voltage electron microscopes. (author)

  11. Radiation shielding and dose rate distribution for the building of the high dose rate accelerator

    International Nuclear Information System (INIS)

    Matsuda, Koji; Takagaki, Torao; Nakase, Yoshiaki; Nakai, Yohta.

    1984-03-01

    A high dose rate electron accelerator was established at Osaka Laboratory for Radiation Chemistry, Takasaki Establishment, JAERI in the fiscal year of 1975. This report shows the fundamental concept for the radiation shielding of the accelerator building and the results of their calculations which were evaluated through the model experiments. After the construction of the building, the leak radiation was measured in order to evaluate the calculating method of radiation shielding. Dose rate distribution of X-rays was also measured in the whole area of the irradiation room as a data base. (author)

  12. Effective dose calculation in CT using high sensitivity TLDs

    International Nuclear Information System (INIS)

    Brady, Z.; Johnston, P.N.

    2010-01-01

    Full text: To determine the effective dose for common paediatric CT examinations using thermoluminescence dosimetry (TLD) mea surements. High sensitivity TLD chips (LiF:Mg,Cu,P, TLD-IOOH, Thermo Fisher Scientific, Waltham, MA) were calibrated on a linac at an energy of 6 MY. A calibration was also performed on a superricial X-ray unit at a kilovoltage energy to validate the megavoltage cali bration for the purpose of measuring doses in the diagnostic energy range. The dose variation across large organs was assessed and a methodology for TLD placement in a 10 year old anthropomorphic phantom developed. Effective dose was calculated from the TLD measured absorbed doses for typical CT examinations after correcting for the TLD energy response and taking into account differences in the mass energy absorption coefficients for different tissues and organs. Results Using new tissue weighting factors recommended in ICRP Publication 103, the effective dose for a CT brain examination on a 10 year old was 1.6 millisieverts (mSv), 4.9 mSv for a CT chest exa ination and 4.7 mSv for a CT abdomen/pelvis examination. These values are lower for the CT brain examination, higher for the CT chest examination and approximately the same for the CT abdomen/ pelvis examination when compared with effective doses calculated using ICRP Publication 60 tissue weighting factors. Conclusions High sensitivity TLDs calibrated with a radiotherapy linac are useful for measuring dose in the diagnostic energy range and overcome limitations of output reproducibility and uniformity asso ciated with traditional TLD calibration on CT scanners or beam quality matched diagnostic X-ray units.

  13. Implementation of high-dose chemical dosimetry for industrial facilities

    International Nuclear Information System (INIS)

    Conceicao, Cirilo Cezar Sant'Anna da

    2006-01-01

    The purpose of this work is the implementation of methodology for high dose measurements using chemical dosimeters in liquid phase, traceable to the international metrology system, and make available in the country, the standard of high-dose to industrial irradiation facilities and research irradiators, trough the quality program with comparative measurements and direct use of the standard dosimeters in routine. The use of these low cost dosimetry systems in industrial irradiation facilities, assists to the certification requirements and it can reduce the costs with dosimetry for approximately 20% of the total dosimetry costs, using these systems in routine measurements and validation process, largely substituting the imported PMMA dosimeters, among others. (author)

  14. Characterization of Thymol blue Radiochromic dosimeters for high dose applications

    Directory of Open Access Journals (Sweden)

    Feras M. Aldweri

    2018-03-01

    Full Text Available Thymol blue (TB solutions and Thymol blue Polyvinyl Alcohol (TB-PVA films have been introduced as Radiochromic dosimeter for high dose applications. The dosimeters were irradiated with gamma ray (60Co source from 5 to 30 kGy for film, and from 0.150 kGy to 4 kGy for solution. The optical density of unirradiated and irradiated TB solution as well as TB-PVA film dosimeters were studied in terms of absorbance at 434 nm using UV/VIS spectrophotometer. The effects of scan temperature, light pre-gamma irradiation, dose rate, relative humidity and stability of the absorbance of solutions and films after irradiation were investigated. We found the dose sensitivity of TB solution and TB-PVA film dosimeters increases significantly with increases of the absorbed dose as well as with the increases of TB dye concentrations. The useful dose range of developed TB solutions and TB-PVA films dosimeters is in the range 0.125–1 kGy and of 5–20 kGy, respectively. Keywords: Dose sensitivity, Radio-chromic dosimeter, Thymol blue, Absorbance, Concentrations

  15. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  16. Safety and tolerability of high doses of glucocorticoides

    Directory of Open Access Journals (Sweden)

    Rakić Branislava D.

    2016-01-01

    Full Text Available Introduction: Treatment of acute lymphoblastic leukemia includes the use of high doses of glucocorticoides (prednisone and dexamethasone, which significantly increase the success of therapy due to lymphocytolitic effect. The aim: The aim of the study was to determine tolerability of high doses of prednisone and dexamethasone in children with acute lymphoblastic leukemia and the structure and the intensity of adverse effects, occurred after application of these medicines. Subjects and methods: In a prospective study, we analyzed adverse effects of high doses of glucocorticoides in children suffering acute lymphoblastic leukemia treated in the Institute for Child and Youth Health Care of Vojvodina, since December 2010. until October 2014, were analyzed. This study included 18 patients, aged from 2 to 15 years. Results: Hyperglycemia appeared in 89% of patients treated with prednisone and in 61% of patients treated with dexamethasone. In order to control the high blood glucose level (above 10 mmol /L, in 11% of patients insulin was used. Hypertension appeared in 28% patients treated with prednisone and dexamethasone. Antihypertensives were needed for regulation in 17% patients. Hypopotassemia and hypocalcaemia were significantly more expressed after the use of prednisone in comparison to dexamethasone. In 11% of patients, the treatment with dexamethasone caused depressive behavior, followed by agitation. Conclusion: Adverse effects of dexamethasone and prednisone, administered in high doses in children with ALL were known, expected and reversible. Adverse reactions usually disappeared spontaneously or after short-term symptomatic therapy.

  17. Low dose radiation enhance the anti-tumor effect of high dose radiation on human glioma cell U251

    International Nuclear Information System (INIS)

    Wang Chang; Wang Guanjun; Tan Yehui; Jiang Hongyu; Li Wei

    2008-01-01

    Objective: To detect the effect on the growth of human glioma cell U251 induced by low dose irradiation and low dose irradiation combined with large dose irradiation. Methods: Human glioma cell line U251 and nude mice carried with human glioma were used. The tumor cells and the mice were treated with low dose, high dose, and low dose combined high dose radiation. Cells growth curve, MTT and flow cytometry were used to detect the proliferation, cell cycle and apoptosis of the cells; and the tumor inhibition rate was used to assess the growth of tumor in vivo. Results: After low dose irradiation, there was no difference between experimental group and control group in cell count, MTT and flow cytometry. Single high dose group and low dose combined high dose group both show significantly the suppressing effect on tumor cells, the apoptosis increased and there was cell cycle blocked in G 2 period, but there was no difference between two groups. In vivo apparent anti-tumor effect in high dose radiation group and the combining group was observed, and that was more significant in the combining group; the prior low dose radiation alleviated the injury of hematological system. There was no difference between single low dose radiation group and control. Conclusions: There is no significant effect on human glioma cell induced by low dose radiation, and low dose radiation could not induce adaptive response. But in vivo experience, low dose radiation could enhance the anti-tumor effect of high dose radiation and alleviated the injury of hematological system. (authors)

  18. HIGH-DOSE RATE BRACHYTHERAPY IN CARCINOMA CERVIX STAGE IIIB

    Directory of Open Access Journals (Sweden)

    Sathya Maruthavanan

    2016-07-01

    Full Text Available INTRODUCTION Radiotherapy is the standard treatment in locally advanced (IIB-IVA and early inoperable cases. The current standard of practice with curable intent is concurrent chemoradiation in which intracavitary brachytherapy is an integral component of radiotherapy. This study aims at assessing the efficacy of HDR ICBT (High-dose rate intracavitary brachytherapy in terms local response, normal tissue reactions, and feasibility. METHODS AND MATERIALS A total of 20 patients of stage IIIB cancer of the uterine cervix were enrolled in the study and were planned to receive concurrent chemotherapy weekly along with EBRT (external beam radiotherapy to a dose of 50 Gy/25 Fr. Suitability for ICBT was assessed at 40 Gy/20 Fr. 6/20 patients were suitable at 40 Gy and received HDR ICBT with a dose of 5.5 Gy to point A in 4 sessions (5.5 Gy/4 Fr. The remaining 14/20 patients completed 50 Gy and received HDR ICBT with a dose of 6 Gy to point A in 3 sessions (6 Gy/3 Fr. RESULTS A total of 66 intracavitary applications were done and only one application required dose modification due to high bladder dose, the pelvic control rate was 85% (17/20. 10% (2/20 had stable disease and 5% (1/20 had progressive disease at one year of follow up. When toxicity was considered only 15% developed grade I and grade II rectal complications. Patient compliance and acceptability was 100%. Patients were very comfortable with the short treatment time as compared with patients on LDR ICBT (low-dose rate intracavitary brachytherapy treatment interviewed during the same period. CONCLUSION This study proves that HDR brachytherapy is efficacious and feasible in carcinoma of cervix stage IIIB. It also proves that good dose distribution can be achieved with HDR intracavitary facility by the use of dose optimization. The short treatment time in HDR ICBT makes it possible to maintain this optimised dose distribution throughout the treatment providing a gain in the therapeutic ratio and

  19. The influence of high doses of radiation in citrine stones

    International Nuclear Information System (INIS)

    Teixeira, M. I.; Caldas, L. V. E.

    2014-08-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  20. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  1. Multifocal Electroretinography after High Dose Chloroquine Therapy for Malaria

    Directory of Open Access Journals (Sweden)

    Aline Correa de Carvalho

    2013-01-01

    Full Text Available Purpose: To investigate changes in multifocal electroretinography (mfERG parameters associated with high dose chloroquine therapy for treatment of malaria in the Amazonia region of Brazil. Methods: Forty-eight subjects who had received chloroquine treatment for single or multiple malaria infections with a cumulative dose ranging from 1,050 to 27,000mg were included. The control group consisted of 37 healthy aged-matched subjects. Data was collected on amplitude and implicit time of the N1, P1 and N2 waves in the central macular hexagon (R1 and in five concentric rings at different retinal eccentricities (R2-R6. Results: No significant difference was observed in any mfERG parameter between chloroquine treated patients and control subjects. A comparison with previous data obtained from patients with rheumatologic disorders in the same region of Brazil who had received larger cumulative doses of chloroquine and had displayed mfERG changes, indicated that retinal toxicity seems to be dependent on cumulative dose. Conclusion: Lack of mfERG changes in the current study suggests that intensive high dose chloroquine therapy for treatment of malaria is not associated with retinal toxicity.

  2. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  3. Use of glasses as radiation detectors for high doses

    International Nuclear Information System (INIS)

    Caldas, L.

    1989-08-01

    Glass samples were tested in relation to the possibility of use in high dose dosimetry in medical and industrial areas. The main characteristics were determined: detection threshold, reproducibility, response to gamma radiation of 137 Cs and 6 Co and thermal decay at ambient temperature, with the use of optical absorption and thermoluminesce techniques. (author) [pt

  4. Oval pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    Hoogendijk, JE; Wokke, JHJ; de Visser, M

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Sis patients responded. Side effects

  5. Oral pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    van der Meulen, M. F.; Hoogendijk, J. E.; Wokke, J. H.; de Visser, M.

    2000-01-01

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Six patients responded. Side effects

  6. High-dose acetylcysteine in idiopathic pulmonary fibrosis

    NARCIS (Netherlands)

    Demedts, Maurits; Behr, Juergen; Buhl, Roland; Costabel, Ulrich; Dekhuijzen, Richard; Jansen, Henk M.; MacNee, William; Thomeer, Michiel; Wallaert, Benoit; Laurent, François; Nicholson, Andrew G.; Verbeken, Eric K.; Verschakelen, Johny; Flower, Christopher D. R.; Capron, Frédérique; Petruzzelli, Stefano; de Vuyst, Paul; van den Bosch, Jules M. M.; Rodriguez-Becerra, Eulogio; Corvasce, Giuseppina; Lankhorst, Ida; Sardina, Marco; Montanari, Mauro

    2005-01-01

    BACKGROUND Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily) added

  7. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  8. Unusual complication and successful high-dose chemotherapy ...

    African Journals Online (AJOL)

    ... treated with high-dose chemotherapy in our institution, complicated by unusual bilateral renal vein tumour thrombi and tumour lysis syndrome. We believe this unique case highlights the need for early recognition of current and potential complications on staging computed tomography imaging, as well as successful use of ...

  9. A clinical comparison of high dose and low dose of Suxamethonium

    Directory of Open Access Journals (Sweden)

    RK Yadav

    2014-01-01

    Full Text Available Background: Suxamethonium having its rapid onset and short duration of action makes this drug unique amongst the neuromuscular blocking drugs described so far. However, use of suxamethonium is associated with a large number of undesirable side effects. Objective: To evaluate clinical effects of high and low dose of suxamethonium and to determine whether lower dose of suxamethonium can be used for any beneficial effects in terms of its various adverse effects e.g. cardiovascular responses, post-operative muscle pains and intraocular pressure. Methods: A total of 100 patients were included in this prospective study. All these patients on preoperative clinical evaluation were assessed to have adequate airway. All the patients were divided in two groups, low dose group (group I and High dose group (group II with 50 patients in each at random. A standard anesthetic technique was adhered to all the patients and following parameters were observed on comparative basis: a. Fasciculation and post operative myalgia. b. Cardiovascular effects, c. Intraocular pressure. Observation: The incidence of post Suxamethonium pain was significantly greater in group II. Increase in heart rate from baseline was significant in both groups. There was no significant difference between the two groups in the diastolic pressure but rise in systolic blood pressure was significant at all assessment times in both groups. This rise from control was statistically significant. Conclusion: Suxamethonium can be used in lower doses (0.5 mg/kg in elective cases without airway compromise. It gives benefits of reduced muscle pains, cardiovascular responses and intraocular hypertension. Journal of College of Medical Sciences-Nepal, 2013, Vol-9, No-2, 1-8 DOI: http://dx.doi.org/10.3126/jcmsn.v9i2.9677

  10. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  11. Radiation processing and high-dose dosimetry at ANSTO

    International Nuclear Information System (INIS)

    Gant, G.J.; Saunders, M.; Banos, C.; Mo, L.; Davies, J.; Evans, O.

    2001-01-01

    The Radiation Technology group at ANSTO is part of the Physics Division and provides services and advice in the areas of gamma irradiation and high-dose dosimetry. ANSTO's irradiation facilities are designed for maximum dose uniformity and provide a precision irradiation service unique in Australia. Radiation Technology makes and sells reference and transfer standard dosimeters which are purchased by users and suppliers of commercial irradiation services in Australia and the Asia-Pacific region. A calibration service is also provided for dosimeters purchased from other suppliers

  12. Australian high-dose-rate brachytherapy protocols for gynaecological malignancy

    International Nuclear Information System (INIS)

    MacLeod, C.; Dally, M.; Stevens, M.; Thornton, D.; Carruthers, S.; Jeal, P.

    2001-01-01

    There is no consensus over the optimal dose fractionation schedules for high-dose-rate (HDR) brachytherapy used for gynaecological malignancy. In Australian public hospital departments of radiation oncology, HDR brachytherapy for gynaecological cancer is being more commonly used. A survey of public departments that are using this technology, or that plan to introduce this technology, was performed. Their current protocols are presented. In general, protocols are similar biologically; however, the practical aspects such as the number of fractions given do vary and may reflect resource restrictions or, alternatively, differences in interpretations of the literature and of the best protocols by clinicians. Copyright (2001) Blackwell Science Pty Ltd

  13. Tolerance of the Brachial Plexus to High-Dose Reirradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Allen M., E-mail: achen5@kumc.edu; Yoshizaki, Taeko; Velez, Maria A.; Mikaeilian, Argin G.; Hsu, Sophia; Cao, Minsong

    2017-05-01

    Purpose: To study the tolerance of the brachial plexus to high doses of radiation exceeding historically accepted limits by analyzing human subjects treated with reirradiation for recurrent tumors of the head and neck. Methods and Materials: Data from 43 patients who were confirmed to have received overlapping dose to the brachial plexus after review of radiation treatment plans from the initial and reirradiation courses were used to model the tolerance of this normal tissue structure. A standardized instrument for symptoms of neuropathy believed to be related to brachial plexus injury was utilized to screen for toxicity. Cumulative dose was calculated by fusing the initial dose distributions onto the reirradiation plan, thereby creating a composite plan via deformable image registration. The median elapsed time from the initial course of radiation therapy to reirradiation was 24 months (range, 3-144 months). Results: The dominant complaints among patients with symptoms were ipsilateral pain (54%), numbness/tingling (31%), and motor weakness and/or difficulty with manual dexterity (15%). The cumulative maximum dose (Dmax) received by the brachial plexus ranged from 60.5 Gy to 150.1 Gy (median, 95.0 Gy). The cumulative mean (Dmean) dose ranged from 20.2 Gy to 111.5 Gy (median, 63.8 Gy). The 1-year freedom from brachial plexus–related neuropathy was 67% and 86% for subjects with a cumulative Dmax greater than and less than 95.0 Gy, respectively (P=.05). The 1-year complication-free rate was 66% and 87%, for those reirradiated within and after 2 years from the initial course, respectively (P=.06). Conclusion: The development of brachial plexus–related symptoms was less than expected owing to repair kinetics and to the relatively short survival of the subject population. Time-dose factors were demonstrated to be predictive of complications.

  14. Analgesic Effect of Tramadol and Buprenorphin in Continuous Propofol Anaesthesia

    Directory of Open Access Journals (Sweden)

    Capík I.

    2016-03-01

    Full Text Available The objective of this study was to compare in clinical patients the analgesic effect of the centrally acting analgesics tramadol and buprenorphine in continuous intravenous anaesthesia (TIVA with propofol. Twenty dogs undergoing prophylactic dental treatment, aged 2−7 years, weighing 6−27 kg, were included in ASA I. and II. groups. Two groups of dogs received intravenous (IV administration of tramadol hydrochloride (2 mg.kg−1 or buprenorphine hydrochloride (0.2 mg.kg−1 30 minutes prior to sedation, provided by midazolam hydrochloride (0.3 mg.kg−1 and xylazine hydrochloride (0.5 mg.kg-1 IV. General anaesthesia was induced by propofol (2 mg.kg−1 and maintained by a 120 minutes propofol infusion (0.2 mg.kg−1min−1. Oscilometric arterial blood pressure (ABP measured in mm Hg, heart rate (HR, respiratory rate (RR, SAT, body temperature (BT and pain reaction elicited by haemostat forceps pressure at the digit were recorded in ten minute intervals. The tramadol group of dogs showed significantly better parameters of blood pressure (P < 0.001, lower tendency to bradycardia (P < 0.05, and better respiratory rate (P < 0.001 without negative influence to oxygen saturation. Statistically better analgesia was achieved in the tramadol group (P < 0.001. Tramadol, in comparison with buprenorphine provided significantly better results with respect to the degree of analgesia, as well as the tendency of complications arising during anaesthesia.

  15. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.; Castro, J.R.; Chen, G.T.Y.; Collier, J.M.; Cartigny, A.; Blakely, E.A.; Lyman, J.T.; Zink, S.R.

    1985-02-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons.

  16. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    International Nuclear Information System (INIS)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.

    1985-01-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons

  17. Dimethyl sulfoxyde diethyl fumarate solution for high dose dosimetry

    International Nuclear Information System (INIS)

    Al-Kassiri, H.; Kattan, M.; Daher, Y.

    2007-06-01

    Dosimetric characterization of diethyl fumarate DEF in dimethyl sulfoxyde DMSO solution has been studied spectrophotometrically for possible application at high dose radiation dosimetry in the range (0-225 kGy). The absorption spectra of irradiated solution showed broad absorption bands between (325-400 nm) with a shoulder at 332 nm. The absorption increases as the dose is increased. Absorbance at 332 nm were measured and plotted against absorbed dose. Linear relationship and good response were found between absorbed dose and absorbance of 20% DEF concentration in the range (0-225 kGy) at the wave length, and linearity up to 250 kGy of absorbance at 332 nm .Good dose rate independence was observed in the range (14-33 kGy/h). The effect of post irradiation storage in darkness and indirect daylight conditions were not found to influence the absorption up to 700 h after irradiation. The effect of irradiation temperature within the range (0 to 60 centigrade degree) on the dosimetry performance was discussed.(author)

  18. Pulsed dose rate and fractionated high dose rate brachytherapy: choice of brachytherapy schedules to replace low dose rate treatments

    International Nuclear Information System (INIS)

    Visser, Andries G.; Aardweg, Gerard J.M.J. van den; Levendag, Peter C.

    1996-01-01

    Purpose: Pulsed dose rate (PDR) brachytherapy is a new type of afterloading brachytherapy (BT) in which a continuous low dose rate (LDR) treatment is simulated by a series of 'pulses,' i.e., fractions of short duration (less than 0.5 h) with intervals between fractions of 1 to a few hours. At the Dr. Daniel den Hoed Cancer Center, the term 'PDR brachytherapy' is used for treatment schedules with a large number of fractions (at least four per day), while the term 'fractionated high dose rate (HDR) brachytherapy' is used for treatment schedules with just one or two brachytherapy fractions per day. Both treatments can be applied as alternatives for LDR BT. This article deals with the choice between PDR and fractionated HDR schedules and proposes possible fractionation schedules. Methods and Materials: To calculate HDR and PDR fractionation schedules with the intention of being equivalent to LDR BT, the linear-quadratic (LQ) model has been used in an incomplete repair formulation as given by Brenner and Hall, and by Thames. In contrast to earlier applications of this model, both the total physical dose and the overall time were not kept identical for LDR and HDR/PDR schedules. A range of possible PDR treatment schedules is presented, both for booster applications (in combination with external radiotherapy (ERT) and for BT applications as a single treatment. Because the knowledge of both α/β values and the half time for repair of sublethal damage (T (1(2)) ), which are required for these calculations, is quite limited, calculations regarding the equivalence of LDR and PDR treatments have been performed for a wide range of values of α/β and T (1(2)) . The results are presented graphically as PDR/LDR dose ratios and as ratios of the PDR/LDR tumor control probabilities. Results: If the condition that total physical dose and overall time of a PDR treatment must be exactly identical to the values for the corresponding LDR treatment regimen is not applied, there appears

  19. High dose rate versus low dose rate interstitial radiotherapy for carcinoma of the floor of mouth

    International Nuclear Information System (INIS)

    Inoue, Takehiro; Inoue, Toshihiko; Yamazaki, Hideya; Koizumi, Masahiko; Kagawa, Kazufumi; Yoshida, Ken; Shiomi, Hiroya; Imai, Atsushi; Shimizutani, Kimishige; Tanaka, Eichii; Nose, Takayuki; Teshima, Teruki; Furukawa, Souhei; Fuchihata, Hajime

    1998-01-01

    Purpose: Patients with cancer of the floor of mouth are treated with radiation because of functional and cosmetic reasons. We evaluate the treatment results of high dose rate (HDR) and low dose rate (LDR) interstitial radiation for cancer of the floor of mouth. Methods and Materials: From January 1980 through March 1996, 41 patients with cancer of the floor of mouth were treated with LDR interstitial radiation using 198 Au grains, and from April 1992 through March 1996 16 patients with HDR interstitial radiation. There were 26 T1 tumors, 30 T2 tumors, and 1 T3 tumor. For 21 patients treated with interstitial radiation alone, a total radiation dose of interstitial therapy was 60 Gy/10 fractions/6-7 days in HDR and 85 Gy within 1 week in LDR. For 36 patients treated with a combination therapy, a total dose of 30 to 40 Gy of external radiation and a total dose of 48 Gy/8 fractions/5-6 days in HDR or 65 Gy within 1 week in LDR were delivered. Results: Two- and 5-year local control rates of patients treated with HDR interstitial radiation were 94% and 94%, and those with LDR were 75% and 69%, respectively. Local control rate of patients treated with HDR brachytherapy was slightly higher than that with 198 Au grains (p = 0.113). For late complication, bone exposure or ulcer occurred in 6 of 16 (38%) patients treated with HDR and 13 of 41 (32%) patients treated with LDR. Conclusion: HDR fractionated interstitial brachytherapy can be an alternative to LDR brachytherapy for cancer of the floor of mouth and eliminate radiation exposure for the medical staff

  20. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko; Furukawa, Souhei; Kakimoto, Naoya

    2003-01-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  1. On the genetic risk after high dose radioiodine therapy with regard to the gonadal dose

    International Nuclear Information System (INIS)

    Ehrenheim, C.; Hauswirth, C.; Fitschen, J.; Martin, E.; Oetting, G.; Hundeshagen, H.

    1997-01-01

    Aim: The genetic risk for the offspring of patients treated with high doses of radioiodine was to be assessed with special regard to the gonadal dose caused by diagnostic and therapeutic procedures. Methods: 41 young females (aged between 19 and 39 years) and four young males (aged 26 to 36 years) treated with radioiodine because of a thyroid carcinoma were interviewed by use of a questionnaire. The course of pregnancy and birth history could be documented as well as the congenital and developmental conditions of 56 children. Results: The amount of radioactivity applied for therapy and whole body scans ranged over 4,144 and 35,15 GBq I-131; the individual gonadal dose was calculated based on the MIRD model and ranged over 0,2 and 2,2 Sv (0,51 Sv at a mean). The period of time between the last radioiodine application and confinement was at least 9 months, not exceeding 14 years. As to the course of pregnancy and birth two early abortions, one extrauterine gravidity and one premature birth due to an insufficiency of the placenta were stated. In one case a chromosomal translocation 7/14 occured as a genetic defect which lead to an interruption. The children's development was unconspicuous except of two cases of neurodermatitis as well as multiple allergies and an early closure of the anterior fontanelle in one child each. Conclusion: Although the genetic risk is supposed to increase with the gonadal dose achieved (doubling dose 1 Sv) and the increased risk of any congenital anomaly was calculated as about 13% at a mean in our patients, the rate of genetic determined diseases was not elevated (1,8% or 1/57). Thus, no increase of genetic defects or congenital malformations was reported in a total of 408 children described in the literature and in our group. (orig.) [de

  2. Dental health of young children prenatally exposed to buprenorphine. A concern of child neglect?

    Science.gov (United States)

    Kivistö, K; Alapulli, H; Tupola, S; Alaluusua, S; Kivitie-Kallio, S

    2014-06-01

    To study the oral health and dental neglect of prenatally buprenorphine-exposed 3-year-old children. The study consisted of 51 children who as newborns tested positive for buprenorphine in a urine screen. The control group comprised 68 children previously unexposed to narcotics. The dentist examined the children and interviewed their guardians. Buprenorphine-exposed children exhibited significantly more early childhood caries than did the control group. Caries indices, the number of decayed, missing and filled teeth or tooth surfaces and decayed teeth were greater in the buprenorphine-exposed children than the control children (p = 0.004, p = 0.004, p = 0.001, respectively). In the buprenorphine group, more children showed visible plaque (p = 0.003) and fewer children were caries-free (p = 0.009) than in the control group. The control children's teeth were also brushed more often than the buprenorphine-exposed children's teeth (p = 0.001) and the parents were more involved in their children's tooth brushing than were those in the buprenorphine-exposed group (p = 0.035). More caries and dental neglect were found in buprenorphine-exposed children than in controls. These findings highlight the importance of routine dental appointments, caries screening and preventive care for children in substance-abusing families.

  3. Methadone, Buprenorphine, and Naltrexone for the Treatment of Opioid Use Disorder in Pregnant Women.

    Science.gov (United States)

    Tran, Tran H; Griffin, Brooke L; Stone, Rebecca H; Vest, Kathleen M; Todd, Timothy J

    2017-07-01

    Pregnant women with opioid use disorder can be treated with methadone, buprenorphine, or naltrexone to reduce opioid use and improve retention to treatment. In this review, we compare the pregnancy outcomes of methadone, buprenorphine, and naltrexone in clinical trials and discuss the potential behavioral and developmental effects of these agents seen in offspring in animal studies. Important clinical considerations in the management of opioid use disorder in pregnant women and their infants are also discussed. Outside of pregnancy, buprenorphine is used in combination with naloxone to reduce opioid abuse and diversion. During pregnancy, however, the use of buprenorphine as a single agent is preferred to prevent prenatal naloxone exposure. Both methadone and buprenorphine are widely used to treat opioid use disorder; however, compared with methadone, buprenorphine is associated with shorter treatment duration, less medication needed to treat neonatal abstinence syndrome (NAS) symptoms, and shorter hospitalizations for neonates. Despite being the standard of care, medication-assisted treatment with methadone or buprenorphine is still underused, making it apparent that more options are necessary. Naltrexone is not a first-line treatment primarily because both detoxification and an opioid-free period are required. More research is needed to determine naltrexone safety and benefits in pregnant women. Animal studies suggest that changes in pain sensitivity, developmental processes, and behavioral responses may occur in children born to mothers receiving methadone, buprenorphine, or naltrexone and is an area that warrants future studies. © 2017 Pharmacotherapy Publications, Inc.

  4. High dose calibrations at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    McDonald, J.C.; Fox, R.A.

    1988-10-01

    The need is increasing for both high radiation exposures and calibration measurements that provide traceability of such exposures to national standards. The applications of high exposures include: electronic component damage studies, sterilization of medical products and food irradiation. Accurate high exposure measurements are difficult to obtain and cannot, in general, be carried out with a single dose measurement system or technique because of the wide range of doses and the variety of materials involved. This paper describes the dosimetric measurement and calibration techniques used at the Pacific Northwest Laboratory (PNL) that make use of radiochromic dye films, thermoluminescent dosimeters (TLDs), ionization chambers, and calorimetric dosimeters. The methods used to demonstrate the consistency of PNL calibrations with national standards will also be discussed. 4 refs

  5. Clinical effects of buprenorphine on open field behaviour and gait symmetry in healthy and lame weaned piglets.

    Science.gov (United States)

    Meijer, Ellen; van Nes, Arie; Back, Willem; van der Staay, Franz Josef

    2015-12-01

    Lameness in pigs decreases animal welfare and economic profit for the farmer. An important reason for impaired welfare in lame animals is pain due to lameness. No direct measurement of pain is possible in animals, and methods to indirectly detect and quantify the amount of pain an animal is experiencing are urgently needed. In this study, two methods to assess pain associated with lameness in pigs were evaluated to determine if they were sensitive enough to detect a lameness reduction as an effect of an experimental analgesic medication. Asymmetry associated with lameness was objectively quantified using pressure mat kinetic parameters: peak vertical force (PVF), load rate (LR), vertical impulse (VI) and peak vertical pressure (PVP). Locomotor activity was assessed in an open field test. A dose of 0.04 mg/kg buprenorphine, a strong analgesic, was used to treat 10 lame pigs, while eight other lame pigs, treated with physiological saline solution, served as controls. Buprenorphine decreased lameness-associated asymmetry for pressure mat LR (P = 0.002), VI (P = 0.003) and PVP (P = 0.001) and increased activity of the lame pigs in the open field (P = 0.023), while saline-treated animals did not show any changes in asymmetry and became less active in the open field (P open field test are both sensitive enough to detect the analgesic effects of buprenorphine when used to treat moderate to severe clinical pain in a relatively small group of affected pigs. The methods used in this study may also provide promising additional tools for future research into early pain recognition and lameness treatment in pigs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Low dose rate and high dose rate intracavitary treatment for cervical cancer

    International Nuclear Information System (INIS)

    Hareyama, Masato; Oouchi, Atsushi; Shidou, Mitsuo

    1997-01-01

    From 1984 through 1993, 144 previous untreated patients with carcinoma of uterine cervix were treated with either low dose rate 137 Cs therapy (LDR) or high dose rate 60 Co therapy (HDR). The local failure rates for more than 2-years for the primary lesions were 11.8% (8 of 63 patients) for LDR and 18.0% (11 of 61 patients). Rectal complication rates were significantly lower for HDR versus LDR (14.3% VS. 32.8%. p<0.01). Also, bladder complication rates were significantly lower for HDR versus LDR (0% VS. 10.4%, p<0.005). Treatment results in term of local control were equivalent for HDR and LDR treatment. However, the incidence of complications was higher for the LDR group than for the HDR group. (author)

  7. The New Kid on the Block--Incorporating Buprenorphine into a Medical Toxicology Practice.

    Science.gov (United States)

    Wiegand, Timothy J

    2016-03-01

    Buprenorphine represents a safe and effective therapy for treating opioid dependence, alleviating craving and withdrawal symptoms in opioid-dependent patients. Buprenorphine has a "blocking" effect against the action of other opioids at the mu-receptor, preventing not only opioid-induced euphoria, but CNS and respiratory depressant effects as well. Buprenorphine was approved for the treatment of opioid dependence in 2002 after the passage of Drug Abuse Treatment Act 2000 (DATA 2000) which allowed clinicians to treat opioid-dependent patients with specifically named opioid agonist therapies in an office setting. Buprenorphine programs reduce the prevalence of HIV and hepatitis C and reduce criminal behaviors associated with illicit drug use. Patients stabilized on buprenorphine have increased employment, enhanced engagement with social services, and better overall health and well-being.

  8. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  9. High-dose secondary calibration laboratory accreditation program

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1993-01-01

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program

  10. Anticoagulation and high dose liver radiation. A preliminary report

    International Nuclear Information System (INIS)

    Lightdale, C.J.; Wasser, J.; Coleman, M.; Brower, M.; Tefft, M.; Pasmantier, M.

    1979-01-01

    Two groups of patients were observed for evidence of acute radiation hepatitis during high dose radiation to the liver. The first group of 18 patients with metastatic liver disease received an average of 4,050 rad to the whole liver. Half received anticoagulation with warfarin. One patient on anticoagulation developed evidence of acute radiation hepatitis while 2 patients did so without anticoagulation. Eleven patients with Hodgkin's disease received 4,000 rad to the left lobe of the liver during extended field radiation. Four of these 11 patients were anticoagulated to therapeutic range. Only one of the fully anticoagulated patients showed changes on liver scan consistent with radiation hepatitis whereas three did so without anticoagulation. No serious sequelae from anticoagulation occurred in either group. These preliminary data suggest that anticoagulation may be safely administered with high dose hepatic radiation and that further trials with anticoagulation are warranted

  11. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxi...

  12. Radiotherapy and high-dose chemotherapy in advanced Ewing's tumors

    International Nuclear Information System (INIS)

    Pape, H.; Glag, M.; Gripp, S.; Wittkamp, M.; Schmitt, G.; Laws, H.J.; Kaik, B. van; Goebel, U.; Burdach, S.; Juergens, H.

    1999-01-01

    Background: Ewing's tumors are sensitive to radio- and chemotherapy. Patients with multifocal disease suffer a poor prognosis. Patients presenting primary bone marrow involvement or bone metastases at diagnosis herald a 3-year disease-free survival below 15%. The European Intergroup Cooperative Ewing's Sarcoma Study (EICESS) has established the following indications for high-dose therapy in advanced Ewing's tumors: Patients with primary multifocal bone disease, patients with early ( [de

  13. Dose characteristics of high-energy electrons, muons and photons

    International Nuclear Information System (INIS)

    Britvich, G.I.; Krupnyj, G.I.; Peleshko, V.N.; Rastsvetalov, Ya.N.

    1980-01-01

    Differential distribution of energy release at different depth of tissue-equivalent phantoms (plexiglas, polystyrene, polyethylene) at the energy of incident electrons, muons of 0.2-40 GeV and photons with the mean energy of 3.6 GeV are measured. The error of experimental results does not exceed 7%. On the basis of the data obtained dose characteristics of electrons, muons and photons for standard geometry are estimated. For all types of irradiation the maximum value of specific equivalent dose, nremxcm 2 /part. is presented. It is shown that published values of specific equivalent dose of electron radiation are higher in all the investigated energy range from 0.2 to 40 GeV, and for muon radiation a good agreement with the present experiment is observed. The highly precise results obtained which cover the wide dynamic range according to the energy of incident particles can serve as the basis for reconsidering the existing recommendations for dose characteristics of electron radiation [ru

  14. Ion exchange resins as high-dose radiation dosimeters

    International Nuclear Information System (INIS)

    Alian, A.; Dessouki, A.; El-Assay, N.B.

    1984-01-01

    This paper reports on the possibility of using various types of ion exchange resins as high-dose radiation dosimeters, by analysis of the decrease in exchange capacity with absorbed dose. The resins studied are Sojuzchim-export-Moscow Cation Exchanger KU-2 and Anion Exchanger AV-17 and Merck Cation Exchanger I, and Merck Anion Exchangers II and III. Over the dose range 1 to 100 kGy, the systems show linearity between log absorbed dose and decrease in resin ion exchange capacity. The slope of this response function differs for the different resins, depending on their ionic form and degree of cross-linking. The radiation sensitivity increases in the order KU-2; Exchanger I; AV-17; Exchanger II; Exchanger III. Merck resins with moisture content of 21% showed considerably higher radiation sensitivity than those with 2 to 3% moisture content. The mechanism of radiation-induced denaturing of the ion exchanger resins involves cleavage and decomposition of functional substituents, with crosslinking playing a stabilizing role, with water and its radiolytic products serving to inhibit radical recombination and interfering with the protection cage effect of crosslinking. (author)

  15. PLUTONIUM/HIGH-LEVEL VITRIFIED WASTE BDBE DOSE CALCULATION

    Energy Technology Data Exchange (ETDEWEB)

    J.A. Ziegler

    2000-11-20

    The purpose of this calculation is to provide a dose consequence analysis of high-level waste (HLW) consisting of plutonium immobilized in vitrified HLW to be handled at the proposed Monitored Geologic Repository at Yucca Mountain for a beyond design basis event (BDBE) under expected conditions using best estimate values for each calculation parameter. In addition to the dose calculation, a plutonium respirable particle size for dose calculation use is derived. The current concept for this waste form is plutonium disks enclosed in cans immobilized in canisters of vitrified HLW (i.e., glass). The plutonium inventory at risk used for this calculation is selected from Plutonium Immobilization Project Input for Yucca Mountain Total Systems Performance Assessment (Shaw 1999). The BDBE examined in this calculation is a nonmechanistic initiating event and the sequence of events that follow to cause a radiological release. This analysis will provide the radiological releases and dose consequences for a postulated BDBE. Results may be considered in other analyses to determine or modify the safety classification and quality assurance level of repository structures, systems, and components. This calculation uses best available technical information because the BDBE frequency is very low (i.e., less than 1.0E-6 events/year) and is not required for License Application for the Monitored Geologic Repository. The results of this calculation will not be used as part of a licensing or design basis.

  16. Establishment and verification of dose-response curve of chromosomal aberrations after exposure to very high dose γ-ray

    International Nuclear Information System (INIS)

    Chen Ying; Luo Yisheng; Cao Zhenshan; Liu Xiulin

    2006-01-01

    To estimate accurately biological dose of the victims exposed to high dose, the dose-response curves of chromosome aberration induced by 6-22 Gy 60 Co γ-ray were established. Human peripheral blood in vitro was irradiated, then lymphocytes were concentrated, cultured 52h, 68h and 72h and harvested. The frequencies of dicentrics (multi-centrics) and rings were counted and compared between different culture times. The dose-response curves and equations were established, as well as verified with high dose exposure accidents. The experiment showed that the culture time should be prolonged properly after high dose exposure, and no significant differences were observed between 52-72h culture. The dose-response curve of 6-22 Gy fitted to linear-square model Y=-2.269 + 0.776D - 7.868 x 10 -3 D 2 and is reliable through verification of the accident dose estimations. In this study, the dose-response curve and equation of chromosome dic + r after 6-22 Gy high dose irradiation were established firstly, and exact dose estimation can be achieved according to it. (authors)

  17. Survey on patient doses in cardiology in Latin America. Criteria for high skin doses follow up

    International Nuclear Information System (INIS)

    Duran, Ariel; Duro, Ivanna; Lopez, Leonardo; Ramirez, Alfredo; Herrera, Carlos; Navarro, Joaquin; Rivarola, Carlos; Lopez, Jose A.

    2008-01-01

    Full text: As part of the International Action Plan for Protection of Patients and supporting by the IAEA, a survey on patient doses in fluoroscopy guided procedures in cardiology in Latin America has been conducted since 2006. One of the objectives of the survey was to set criteria for the identification and evaluation of high skin doses in a certain number of patients to recommend a clinical follow up for potential radiation injuries (more than 3 Gy at the skin). The used methodology for the survey was initiated with two dedicated workshops held in Santiago de Chile (2005) and San Jose de Costa Rica (2007) involving relevant cardiologists from 15 different Latin American Countries. Some sessions were also attended by experts from the Regulatory and Health Authorities. Standardized forms to collect demographic and patient dosimetric data were agreed. Considering that most of the involved centres had still not dosimeters installed in the cardiology x-ray systems, it was agreed to collect data on fluoroscopy time and total number of cine frames per procedure. Relevant factors influencing radio sensitivity of the skin were also collected. Data from 10 countries representing a sample of 709 patients were received during the first year. Procedures included were diagnostic (DG) (coronary angiography and electrophysiology studies), therapeutic (TH) (percutaneous transluminal coronary angioplasties, cardiac ablations and valvuloplasties) or including both DG and TH. A total of 26 patients (3.7%) were selected for potential high skin doses. Initial considered criteria for selection were more than 30 minutes of fluoroscopy, more than 3,000 cine frames per procedure or patients with more than 100 kg of weight. Maximum reported values were 72 minutes and 8,100 frames. In addition, 5 of these patients were diabetic, 6 have previous fluoroscopy procedures and 5 were over 95 kg. The percentage of selected cases for clinical follow up derived from potential skin injuries seem

  18. Postoperative Analgesia Due to Sustained-Release Buprenorphine, Sustained-Release Meloxicam, and Carprofen Gel in a Model of Incisional Pain in Rats (Rattus norvegicus).

    Science.gov (United States)

    Seymour, Travis L; Adams, Sean C; Felt, Stephen A; Jampachaisri, Katechan; Yeomans, David C; Pacharinsak, Cholawat

    2016-01-01

    Postoperative analgesia in laboratory rats is complicated by the frequent handling associated with common analgesic dosing requirements. Here, we evaluated sustained-release buprenorphine (Bup-SR), sustained-release meloxicam (Melox-SR), and carprofen gel (CG) as refinements for postoperative analgesia. The aim of this study was to investigate whether postoperative administration of Bup-SR, Melox-SR, or CG effectively controls behavioral mechanical and thermal hypersensitivity in a rat model of incisional pain. Rats were randomly assigned to 1 of 5 treatment groups: saline, 1 mL/kg SC BID; buprenorphine HCl (Bup HCl), 0.05 mg/kg SC BID; Bup-SR, 1.2 mg/kg SC once; Melox-SR, 4 mg/kg SC once; and CG, 2 oz PO daily. Mechanical and thermal hypersensitivity were tested daily from day-1 through 4. Bup HCl and Bup-SR attenuated mechanical and thermal hypersensitivity on days 1 through 4. Melox-SR and CG attenuated mechanical hypersensitivity-but not thermal hypersensitivity-on days 1 through 4. Plasma concentrations, measured by using UPLC with mass spectrometry, were consistent between both buprenorphine formulations. Gross pathologic examination revealed no signs of toxicity in any group. These findings suggest that postoperative administration of Bup HCl and Bup-SR-but not Melox-SR or CG-effectively attenuates mechanical and thermal hypersensitivity in a rat model of incisional pain.

  19. Methadone inhibits CYP2D6 and UGT2B7/2B4 in vivo: a study using codeine in methadone- and buprenorphine-maintained subjects

    Science.gov (United States)

    Gelston, Eloise A; Coller, Janet K; Lopatko, Olga V; James, Heather M; Schmidt, Helmut; White, Jason M; Somogyi, Andrew A

    2012-01-01

    AIMS To compare the O-demethylation (CYP2D6-mediated), N-demethylation (CYP3A4-mediated) and 6-glucuronidation (UGT2B4/7-mediated) metabolism of codeine between methadone- and buprenorphine-maintained CYP2D6 extensive metabolizer subjects. METHODS Ten methadone- and eight buprenorphine-maintained subjects received a single 60 mg dose of codeine phosphate. Blood was collected at 3 h and urine over 6 h and assayed for codeine, norcodeine, morphine, morphine-3- and -6-glucuronides and codeine-6-glucuronide. RESULTS The urinary metabolic ratio for O-demethylation was significantly higher (P = 0.0044) in the subjects taking methadone (mean ± SD, 2.8 ± 3.1) compared with those taking buprenorphine (0.60 ± 0.43), likewise for 6-glucuronide formation (0.31 ± 0.24 vs. 0.053 ± 0.027; P D6 and UGTs 2B4 and 2B7 reactions in vivo, even though it is not a substrate for these enzymes. Plasma morphine was not altered, owing to the opposing effects of inhibition of both formation and elimination; however, morphine-6-glucuronide (analgesically active) concentrations were substantially reduced. Drug interactions with methadone are likely to include drugs metabolized by various UGTs and CYP2D6. PMID:22092298

  20. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva; Yoriyaz, Hélio; Tedgren, Åsa Carlsson; Nilsson, Josef; Persson, Maria; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (D m,m ) and dose-to-water-in-medium (D w,m ). The relation between D m,m and D w,m for 192 Ir is the main goal of this study, in particular the dependence of D w,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: D m,m, D w,m (LCT), mean photon energy and photon fluence. D w,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between D m,m and D w,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between D w,m (SCT) and D w,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between D m,m and D w,m (SCT) mainly depend on tissue type, differences between D m,m and D w,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources. (paper)

  1. High dose vitamin K3 infusion in advanced hepatocellular carcinoma.

    Science.gov (United States)

    Sarin, Shiv K; Kumar, Manoj; Garg, Sanjay; Hissar, Syed; Pandey, Chandana; Sharma, Barjesh C

    2006-09-01

    The survival of patients with unresectable advanced hepatocellular carcinoma (HCC) with portal vein thrombosis is dismal. Current therapeutic options have limited efficacy. Vitamin K has been shown to have antitumor effect on HCC cells both in cell lines and patients with advanced HCC. The aim of this study was to assess the clinical efficacy of high dose vitamin K3 in the treatment of advanced HCC with portal vein thrombosis. Forty-two consecutive patients with advanced HCC (Stage C according to BCLC staging system) with portal vein thrombosis were randomized into two groups: (i) high dose vitamin K3 (n = 23); and (ii) placebo (n = 19). The vitamin K3 was administered by i.v. infusion of 50 mg/day with daily increase of dose by 50 mg for 6 days, followed by 20 mg i.m. twice daily for 2 weeks. Of the 23 patients treated with vitamin K, one (4.3%) achieved complete response and three (13%) partial response, for a total of four (17.4%) objective responders overall. The overall mean survival was 8.9 +/- 8.8 months (median: 6; range 1-37 months) in the vitamin K group and 6.8 +/- 5.3 months (median: 5; range 1.5-21 months) in the placebo group (P = 0.552). The mean duration of survival was longer in patients in the vitamin K group who achieved objective response (22.5 +/- 12.2; median: 21; range 11-37 months) as compared to patients not achieving objective response (6.1 +/- 4.6; median: 5; range 1-16 months) (P = 0.0.002). Portal vein thrombosis resolved with complete patency in one (4.35%) patient. Treatment with high dose vitamin K produces objective response in 17% patients with improved survival in patients achieving objective response; however, it does not affect the overall survival.

  2. High-dose preoperative radiation for cancer of the rectum: Impact of radiation dose on patterns of failure and survival

    International Nuclear Information System (INIS)

    Ahmad, N.R.; Mohiuddin, M.; Marks, G.

    1993-01-01

    A variety of dose-time schedules are currently used for preoperative radiation therapy of rectal cancer. An analysis of patients treated with high-dose preoperative radiation therapy was undertaken to determine the influence of radiation dose on the patterns of failure, survival, and complications. Two hundred seventy-five patients with localized rectal cancer were treated with high-dose preoperative radiation therapy. One hundred fifty-six patients received 45 Gy (low-dose group). Since 1985, 119 patients with clinically unfavorable cancers were given a higher dose, 55 Gy using a shrinking field technique (high-dose group). All patients underwent curative resection. Median follow-up was 66 months in the low-dose group and 28 months in the high-dose group. Patterns of failure, survival, and complications were analyzed as a function of radiation dose. Fourteen percent of the total group developed a local recurrence; 20% in the low-dose group as compared with 6% in the high-dose group. The actuarial local recurrence rate at 5 years was 20% for the low-dose group and 8% for the high-dose group, and approached statistical significance with p = .057. For tethered/fixed tumors the actuarial local recurrence rates at 5 years were 28% and 9%, respectively, with p = .05. Similarly, for low-lying tumors (less than 6 cm from the anorectal junction) the rates were 24% and 9%, respectively, with p = .04. The actuarial rate of distant metastasis was 28% in the low-dose group and 20% in the high-dose group and was not significantly different. Overall actuarial 5-year survival for the total group of patients was 66%. No significant difference in survival was observed between the two groups, despite the higher proportion of unfavorable cancers in the high-dose group. The incidence of complications was 2%, equally distributed between the two groups. High-dose preoperative radiation therapy for rectal cancer results in excellent local control rates. 27 refs., 2 figs., 8 tabs

  3. Methodology of high dose research in medical radiodiagnostic; Metodologia de investigacao de doses elevadas em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana E.; Martins, Cintia P. de S., E-mail: ird@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations.

  4. Carprofen neither reduces postoperative facial expression scores in rabbits treated with buprenorphine nor alters long term bone formation after maxillary sinus grafting.

    Science.gov (United States)

    Hedenqvist, Patricia; Trbakovic, Amela; Thor, Andreas; Ley, Cecilia; Ekman, Stina; Jensen-Waern, Marianne

    2016-08-01

    In connection with bilateral maxillary sinus augmentation, the acute effects of the nonsteroidal anti-inflammatory drug carprofen on facial expressions and long-term effects on bone formation were evaluated in 18 male New Zealand White rabbits. A 10×10mm bone window was drilled in the maxilla, the sinus membrane elevated and a titanium mini-implant inserted. One of two test materials was randomly inserted unilaterally and bovine bone chips (control) on the contralateral side in the created space. Rabbits were randomly allocated to receive buprenorphine plus carprofen (n=9) or buprenorphine plus saline (n=9) postoperatively. Buprenorphine was administered subcutaneously every 6h for 3days in a tapered dose (0.05-0.01mg/kg) and carprofen (5mg/kg) or saline administered subcutaneously 1h before, and daily for 4days postoperatively. To assess pain, clinical examination, body weight recording and scoring of facial expressions from photos taken before, and 6-13h after surgery were performed. Twelve weeks after surgery the rabbits were euthanized and sections of maxillary bones and sinuses were analysed with histomorphometry and by qualitative histology. Carprofen had no effect on mean facial expression scores, which increased from 0.0 to 3.6 (carprofen) and 4.3 (saline), of a maximum of 8.0. Neither did carprofen have an effect on bone formation or implant incorporation, whereas the test materials had. In conclusion, treatment with 5mg/kg carprofen once daily for 5days did not reduce facial expression scores after maxillary sinus augmentation in buprenorphine treated rabbits and did not affect long term bone formation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Routine quality control of high dose rate brachytherapy equipment

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira

    2001-01-01

    A Quality Assurance program should be installed also for High Dose Rate brachytherapy, in the order to achieve a correct dose administration to the patient and for the safety to those involved directly with the treatment. The work presented here has the following purposes: Analyze the types of equipment tests presented by the official protocols (TG40, TG56 e ARCAL XXX), evaluate the brachytherapy routine tests of protocols from various national and international radiotherapy services and compare the latter with those presented in the official protocols. As a result, we conclude the following: TG56 presents a higher number of tests when compared to the other official protocols and most of the tests presented by the analyzed services are present in TG56. A suggestion for a basic protocol is presented, emphasizing the periodicity and tolerance level of each of the tests. (author)

  6. Development of miniature γ dose rate monitor with high sensitivity

    International Nuclear Information System (INIS)

    Shi Huilu; Tuo Xianguo; Xi Dashun; Tang Rong; Mu Keliang; Yang Jianbo

    2009-01-01

    This paper introduces a miniature γ dose rate monitor with high sensitivity which design based on single chip microcomputer, it can continue monitoring γ dose rate and then choose wire or wireless communications to sent the monitoring data to host according to the actual conditions. It has two kinds of power supply system, AC power supply system and battery which can be chose by concrete circumstances. The design idea and implementation technology of hardware and software and the system structure of the monitor are detailed illustrated in this paper. The experimental results show that measurable range is 0.1 mR/h-200 mR/h, the sensitivity of γ is 90 cps/mR/h, dead time below 200 us, error of stability below ±10%. (authors)

  7. High-dose dosimetry using electron spin resonance (ESR) spectroscopy

    International Nuclear Information System (INIS)

    Kojima, Takuji; Tanaka, Ryuichi

    1992-01-01

    An electron spin resonance (ESR) dosimeter capable of measuring large doses of radiation in radiotherapy and radiation processing is outlined. In particular, an alanine/ESR dosimeter is discussed, focusing on the development of elements, the development of the ESR dosimetric system, the application of alanine/ESR dosimeter, and basic researches. Rod elements for gamma radiation and x radiation and film elements for electron beams are described in detail. The following recent applications of the alanine/ESR dosimeter are introduced: using as a transfer dosimeter, applying to various types of radiation, diagnosing the deterioration of radiological materials and equipments, and applying to ESR imaging. The future subjects to be solved in the alanine/ESR dosimetric system are referred to as follows: (1) improvement of highly accurate elements suitable for the measurement of various types of radiation, (2) establishment of sensitive calibration method of the ESR equipment itself, and (3) calibration and standardization of radiation doses. (K.N.) 65 refs

  8. Use of high irradiation doses for preservation of canned beef

    International Nuclear Information System (INIS)

    Hammad, A.A.I; Salem, F.A.; El-Sahy, K.M.; Rady, A.; Badr, H.H.

    1997-01-01

    The effect of high irradiation doses (11.25,22.5 and 45 KGy) on the bacteriology, organoleptic quality and shelf - life extension of beef meat that are hermetically sealed in metal cans was investigated in comparison with commercial heat sterilization. The unirradiated cans of pre cooked (enzyme inactivated) unirradiated beef were swollen after only one month of storage at ambient temperature (20-30 degree). Application of 11.25 and 22.5 kGy to vacuum packed and enzyme inactivated beef was not enough for sterilization and only delayed swelling of beef cans. Application of 45 KGy irradiation dose prevented swelling of beef vans up to 12 months at ambient temperature and provided meat product, similar to the commercial heat sterilized one, organoleptically acceptable and microbiologically safe. Running title: Radiation sterilization of meat

  9. High and low dose-rate brachytherapy for cervical carcinoma

    International Nuclear Information System (INIS)

    Orton, C.G.

    1998-01-01

    For the brachytherapy component of the r[iation treatment of cervical carcinoma, high dose rate (HDR) is slowly replacing conventional low dose rate (LDR) due primarily to r[iation safety and other physical benefits attributed to the HDR modality. Many r[iation oncologists are reluctant to make this change because of perceived r[iobiological dis[vantages of HDR. However, in clinical practice HDR appears to be as effective as LDR but with a lower risk of late complications, as demonstrated by one randomized clinical trial and two comprehensive literature and practice surveys. The reason for this appears to be that the r[iobiological dis[vantages of HDR are outweighed by the physical [vantages. (orig.)

  10. Calibration of high-dose radiation facilities (Handbook)

    International Nuclear Information System (INIS)

    Gupta, B.L.; Bhat, R.M.

    1986-01-01

    In India at present several high intensity radiation sources are used. There are 135 teletheraphy machines and 65 high intensity cobalt-60 sources in the form of gamma chambers (2.5 Ci) and PANBIT (50 Ci). Several food irradiation facilities and a medical sterilization plant ISOMED are also in operation. The application of these high intensity sources involve a wide variation of dose from 10 Gy to 100 kGy. Accurate and reproducible radiation dosimetry is essential in the use of these sources. This handbook is especially compiled for calibration of high-dose radiation facilities. The first few chapters discuss such topics as interaction of radiation with matter, radiation chemistry, radiation processing, commonly used high intensity radiation sources and their special features, radiation units and dosimetry principles. In the chapters which follow, chemical dosimeters are discussed in detail. This discussion covers Fricke dosimeter, FBX dosimeter, ceric sulphate dosimeter, free radical dosimetry, coloured indicators for irrdiation verification. A final chapter is devoted to practical hints to be followed in calibration work. (author)

  11. Low dose versus high dose anti-snake venom therapy in the treatment of haematotoxic snake bite in South India.

    Science.gov (United States)

    Joseph, Imanto M; Kuriakose, Cijoy K; Dev, Anand Vimal; Philip, George A

    2017-10-01

    Most of the studies on the appropriate dose of anti-snake venom (ASV) are from tertiary hospitals and the guidelines are unclear. Our observational study compared the outcomes of two prevalent treatment regimes for haematotoxic snake bite in a secondary care hospital in South India. The time to normalisation of whole blood clotting time, mortality and complications were not different between the groups. The average dose of ASV required in the low and high dose groups were 106 mL and 246 mL, respectively. Consequently, patients who received low dose ASV incurred approximately 50% less expense. Urticarial rashes were also significantly fewer in the low dose group.

  12. [Trend in buprenorphine and methadone shopping behavior in France from 2004 to 2014].

    Science.gov (United States)

    Kernisant, Mélanie; Delorme, Jessica; Kabore, Jean-Luc; Brousse, Georges; Laporte, Catherine; Zenut, Marie; Chenaf, Chouki; Authier, Nicolas

    2016-12-01

    The opioid maintenance treatments (OMT) are widely misused and diverted in many countries. Doctor shopping represented the main way to obtain high quantities of opioids in abuse/diversion. The aim of this study was to assess the trends in the prevalence of doctor shopping for high dosage buprenorphine (HDB) and methadone (MTD) from 2004 to 2014 by using the French Health Insurance claims. This was a cross-sectional study of patients treated by OMT (High Dosage Buprenorphine or Methadone) between 2004 and 2014 from a representative sample of the French Health Insurance claims. Doctor shopping was defined as at least 1 day of overlapping prescriptions, written by at least 2 different prescribers and filled in at least 3 different pharmacies. HDB patients were more likely men (77.9 % in 2014) with a mean age ranged from 33.4±7.6 years in 2004 to 39.5±9.3 years in 2014, Pshopping for HDB decreased from 2004 to 2014 (12.6 % versus 3.9 %, Pshopping for MTD was very low during the period study (0.2 % to 0.5 %). Overall, the prevalence of doctor shopping was higher for HDB than for MTD whatever the year (Pshopping for HDB decreased significantly during the last decade while doctor shopping for MTD remained nearly inexistent even if it could be underestimated because of dispensations in specialized centers and in hospitals not comprised in the insurance claims. The low rates of doctor shopping reported in these last years could result from the guidelines for good practices in OMT use made in 2004 and the adjustments of ANSM (French National Agency for Medicines and Health Products Safety) for HDB best use made in 2011. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. High Doses Gamma Radiolysis of PVC: Mechanisms of Degradation

    International Nuclear Information System (INIS)

    Colombani, J.

    2006-01-01

    PVC radiolysis leads to the formation of various degradation products: radicals, gas, oxidized products or polyenes. In order to predict the formation of the degradation products with regard to irradiation and ageing parameters, it is important to improve the understanding of the radiolysis mechanisms of PVC. Thus, we used several analytical techniques (Electron Spin Resonance, Fourier Transform Infrared spectroscopy, Nuclear Magnetic Resonance, Size Exclusion Chromatography) to get information on PVC samples irradiated at high doses (up to 4MGy) under different conditions. Gamma irradiation induces the formation of various radicals into PVC. Older studies were generally focused on the effect of low dose and/or low temperature irradiations on PVC. We present here ESR signals of PVC irradiated at high doses and at room temperature. We show that peroxyl radicals are producted by radiolysis under aerobe conditions and that polyenyl radicals are formed under anaerobe conditions. PVC radiolysis induces gas production and especially hydrogen chloride. Production of hydrogen chloride is well known until 1 MGy. We have studied by FTIR, the evolution of the quantity of HCl produced until 4 MGy. We show that higher irradiation dose leads to the lower radiolytic yield of HCl (G(HCl)). Moreover, G(HCl) obtained in aerobe conditions is about fourfold as great as G(HCl) observed in anaerobe radiolysis. Propagation and termination reactions induce degradation products: polyene sequences and crosslinking reactions are observed under anaerobe conditions; oxidized products with addition of chain scissions are formed under aerobe conditions. Although the literature about PVC radiolysis is rich, the main reacting pathways are not well established. Moreover the high doses studies are almost non-existent. We show by FTIR that aerobe radiolysis induces formation of ketons and acids. NMR experiments confirme these results but also focuse on small acids formed (with 2, 3 or 4 carbons). The

  14. High-dose radioiodine therapy of Graves disease

    International Nuclear Information System (INIS)

    Solodky, V.; Fomin, D.; Pestritskaya, E.

    2015-01-01

    Full text of publication follows. Objectives: to estimate the effectiveness and safety of the disease treatment under different modes of applying RIT. Materials and methods: 67 patients with the thyrotoxicosis condition associated with Graves disease were researched. The patients were divided into 2 groups: a control group with 25 people (18 women and 7 men), who underwent a low-dose therapy of 150-500 MBq; and a main group of 42 people (32 women and 10 men), who underwent a high-dose therapy of 550 and 800 MBq. The volume of thyroid prior to the treatment made up 23.8 ± 20 ml in the main group and 30.2 ± 23 ml in the control one. The average age in the high-dose group was 44.6 ±23 years old and in the low-dose -47.2 ± 24 years old. In terms of the hormone level before the RIT, 52% of the main group patients experienced euthyroidism, while 48% - thyrotoxicosis. The corresponding indices in the control group were 42% and 58% respectively. The cessation of the thyreostatic therapy came on 5. to 21. day prior to the treatment, with the average of 14 ±7 days in both groups. The diagnosis of the disease was based on ultrasonography, planar scintigraphy, the hormone level and antibody titer. The performance was assessed through the attainment of hypo-thyrosis and the transition to a substitutive hormonal therapy with L-thyroxine in 6 months or more. The attainment of euthyroidism was seen as a partial effect due to a possibility of relapse. Results: in 6 months a positive result in the form of hypo-thyrosis was achieved for 39 patients in the main group, which accounted for 93%, and 3 patients (7%) experienced euthyroidism. No symptomatic thyrotoxicosis relapses were revealed. In the control group, hypo-thyrosis was achieved by 18 patients, which accounted for 72%; euthyroidism came up to 12%; 4 patients needed a refresher course of RIT, which made up 16% of the group. 93% of the main group patients tolerated the treatment favourably. 3 patients complained of the

  15. Cooperative binding mitigates the high-dose hook effect.

    Science.gov (United States)

    Roy, Ranjita Dutta; Rosenmund, Christian; Stefan, Melanie I

    2017-08-14

    The high-dose hook effect (also called prozone effect) refers to the observation that if a multivalent protein acts as a linker between two parts of a protein complex, then increasing the amount of linker protein in the mixture does not always increase the amount of fully formed complex. On the contrary, at a high enough concentration range the amount of fully formed complex actually decreases. It has been observed that allosterically regulated proteins seem less susceptible to this effect. The aim of this study was two-fold: First, to investigate the mathematical basis of how allostery mitigates the prozone effect. And second, to explore the consequences of allostery and the high-dose hook effect using the example of calmodulin, a calcium-sensing protein that regulates the switch between long-term potentiation and long-term depression in neurons. We use a combinatorial model of a "perfect linker protein" (with infinite binding affinity) to mathematically describe the hook effect and its behaviour under allosteric conditions. We show that allosteric regulation does indeed mitigate the high-dose hook effect. We then turn to calmodulin as a real-life example of an allosteric protein. Using kinetic simulations, we show that calmodulin is indeed subject to a hook effect. We also show that this effect is stronger in the presence of the allosteric activator Ca 2+ /calmodulin-dependent kinase II (CaMKII), because it reduces the overall cooperativity of the calcium-calmodulin system. It follows that, surprisingly, there are conditions where increased amounts of allosteric activator actually decrease the activity of a protein. We show that cooperative binding can indeed act as a protective mechanism against the hook effect. This will have implications in vivo where the extent of cooperativity of a protein can be modulated, for instance, by allosteric activators or inhibitors. This can result in counterintuitive effects of decreased activity with increased concentrations of

  16. High-dose MeV electron irradiation of Si-SiO2 structures implanted with high doses Si+

    Science.gov (United States)

    Kaschieva, S.; Angelov, Ch; Dmitriev, S. N.

    2018-03-01

    The influence was studied of 22-MeV electron irradiation on Si-SiO2 structures implanted with high-fluence Si+ ions. Our earlier works demonstrated that Si redistribution is observed in Si+-ion-implanted Si-SiO2 structures (after MeV electron irradiation) only in the case when ion implantation is carried out with a higher fluence (1016 cm-2). We focused our attention on the interaction of high-dose MeV electron irradiation (6.0×1016 cm-2) with n-Si-SiO2 structures implanted with Si+ ions (fluence 5.4×1016 cm-2 of the same order magnitude). The redistribution of both oxygen and silicon atoms in the implanted Si-SiO2 samples after MeV electron irradiation was studied by Rutherford back-scattering (RBS) spectroscopy in combination with a channeling technique (RBS/C). Our results demonstrated that the redistribution of oxygen and silicon atoms in the implanted samples reaches saturation after these high doses of MeV electron irradiation. The transformation of amorphous SiO2 surface into crystalline Si nanostructures (after MeV electron irradiation) was evidenced by atomic force microscopy (AFM). Silicon nanocrystals are formed on the SiO2 surface after MeV electron irradiation. The shape and number of the Si nanocrystals on the SiO2 surface depend on the MeV electron irradiation, while their size increases with the dose. The mean Si nanocrystals height is 16-20 nm after irradiation with MeV electrons at the dose of 6.0×1016 cm-2.

  17. The status of low dose rate and future of high dose rate Cf-252 brachytherapy

    International Nuclear Information System (INIS)

    Rivard, M.J.; Wierzbicki, J.G.; Van den Heuvel, F.; Chuba, P.J.; Fontanesi, J.

    1997-12-01

    This work describes the current status of the US low dose rate (LDR) Cf-252 brachytherapy program. The efforts undertaken towards development of a high dose rate (HDR) remotely after loaded Cf-252 source, which can accommodate 1 mg or greater Cf-252, are also described. This HDR effort is a collaboration between Oak Ridge National Laboratory (ORNL), commercial remote after loader manufactures, the Gershenson Radiation Oncology Center (ROC), and Wayne State University. To achieve this goal, several advances in isotope chemistry and source preparation at ORNL must be achieved to yield a specific material source loading of greater than or equal 1 mg Cf-252 per mm3. Development work with both radioactive and non-radioactive stand-ins for Cf-252 have indicated the feasibility of fabricating such sources. As a result, the decreased catheter diameter and computer controlled source placement will permit additional sites (e.g. brain, breast, prostate, lung, parotid, etc.) to be treated effectively with Cf-252 sources. Additional work at the Radiochemical Engineering and Development Center (REDC) remains in source fabrication, after loader modification, and safe design. The current LDR Cf-252 Treatment Suite at the ROC is shielded and licensed to hold up to 1 mg of Cf-252. This was designed to maintain cumulative personnel exposure, both external to the room and in direct isotope handling, at less than 20 microSv/hr. However, cumulative exposure may be greatly decreased if a Cf-252 HDR unit is employed which would eliminate direct isotope handling and decrease treatment times from tilde 3 hours to an expected range of 3 to 15 minutes. Such a Cf-252 HDR source will also demonstrate improved dose distributions over current LDR treatments due to the ability to step the point-like source throughout the target volume and weight the dwell time accordingly

  18. Diagnosis of cerebral metastases by means of standard doses of Gadobutrol versus a high-dose protocol. Intraindividual evaluation of a phase-II high-dose study

    International Nuclear Information System (INIS)

    Vogl, T.J.; Friebe, C.E.; Balzer, T.; Mack, M.G.; Steiner, S.; Schedel, H.; Pegios, W.; Lanksch, W.; Banzer, D.; Felix, R.

    1995-01-01

    In a clinical phase-II study 20 patients who had been diagnosed as having brain metastases with CT or MRT were studied prospectively with Gadobutrol, a new nonionic, low osmolality contrast agent. Each patient received an initial injection of 0.1 mmol/kg body weight and an additional dose of 0.2 mmol/kg Gadobutrol 10 min later. Spinecho images were obtained before and after the two applications of Gadobutrol. Dynamic scanning (Turbo-FLASH) was performed for 3 min after each injection of the contrast agent. Both quantitative and qualitative data were intraindividually evaluated. The primary tumor was a bronchial carcinoma in 11 cases; in 9 other cases there were different primary tumors. Forty-eight hours after the use of Gadobutrol there were no adverse signs in the clinical examination, vital signs or blood and urine chemistry. Statistical analysis (Friedman test and Wilcoxon test) of the C/N ratios between tumor and white matter, percentage enhancement, and visual assessment rating revealed statistically significant superiority of high-dose Gadobutrol injection in comparison to the standard dose. The percentage enhancement increased on average from 104% after 0.1 mmol/kg to 162% after 0.3 mmol/kg Gadobutrol. Qualitative delineation and contrast of the lesions increased significantly. The use of high-dose Gadobutrol improved the detection of 36 additional lesions in 6 patients. (orig./VHE) [de

  19. Constipation and other common symptoms reported by women and men in methadone and buprenorphine maintenance treatment.

    Science.gov (United States)

    Haber, Paul S; Elsayed, Mahmoud; Espinoza, David; Lintzeris, Nicholas; Veillard, Anne-Sophie; Hallinan, Richard

    2017-12-01

    Opioid substitution treatment (OST) is often continued long-term and, therefore, opioid-associated symptoms are of interest. Symptoms associated with methadone maintenance treatment (MMT) in men are well described, but there are fewer reports concerning symptoms associated with buprenorphine maintenance treatment (BMT) and very few reports among women. Recipients of BMT (n=113) and MMT (n=184), non-opioid users (n=105) and opioid users not receiving OST (n=87) completed the Patient Assessment of Constipation (PAC-SYM) and a general symptom checklist. Multivariate analysis included other potential moderators of opioid-associated symptoms. Opioid users reported a higher frequency and severity of symptoms than non-opioid users. Constipation, dry mouth, decreased appetite, sweating and fatigue were highly prevalent in the previous 30days (51-80%). Nausea, itchy skin, trouble urinating, menstrual problems, lightheadedness, blurred vision, heart racing were also common (30-50%). Non-OST opioid users had significantly higher frequency and severity than OST recipients of nausea, vomiting, diarrhoea, decreased appetite, sweating and itchy skin. Sweating was significantly more common in MMT than BMT. Constipation scores were higher in women, otherwise most sex differences were small. Higher PAC-SYM scores were associated with vomiting (OR=1.04) and sweating (OR=1.06). Cannabis use was associated with vomiting (OR=2.19). Constipation (OR=1.07), insomnia (OR=2.5) and depression (OR=2.82) were associated with fatigue. Men and women receiving OST report similarly high rates of somatic symptoms, though less than opioid users not receiving OST. There were few differences between BMT and MMT. Buprenorphine might be preferred where sweating is problematic. Several modifiable factors were identified. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. High dose tetrabromobisphenol A impairs hippocampal neurogenesis and memory retention.

    Science.gov (United States)

    Kim, Ah Hyun; Chun, Hye Jeong; Lee, Seulah; Kim, Hyung Sik; Lee, Jaewon

    2017-08-01

    Tetrabromobisphenol A (TBBPA) is a brominated flame retardant that is commonly used in commercial and household products, such as, computers, televisions, mobile phones, and electronic boards. TBBPA can accumulate in human body fluids, and it has been reported that TBBPA possesses endocrine disruptive activity. However, the neurotoxic effect of TBBPA on hippocampal neurogenesis has not yet been investigated. Accordingly, the present study was undertaken to evaluate the effect of TBBPA on adult hippocampal neurogenesis and cognitive function. Male C57BL/6 mice were orally administrated vehicle or TBBPA (20 mg/kg, 100 mg/kg, or 500 mg/kg daily) for two weeks. TBBPA was observed to significantly and dose-dependently reduce the survival of newly generated cells in the hippocampus but not to affect the proliferation of newly generated cells. Numbers of hippocampal BrdU and NeuN positive cells were dose-dependently reduced by TBBPA, indicating impaired neurogenesis in the hippocampus. Interestingly, glial activation without neuronal death was observed in hippocampi exposed to TBBPA. Furthermore, memory retention was found to be adversely affected by TBBPA exposure by a mechanism involving suppression of the BDNF-CREB signaling pathway. The study suggests high dose TBBPA disrupts hippocampal neurogenesis and induces associated memory deficits. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Stock selection of high-dose-irradiation-resistant materials for filter press under high-dose irradiation operation

    International Nuclear Information System (INIS)

    Ishiyama, Shintaro; Minami, Mamoru; Hara, Kouji; Yamashita, Manabu

    2015-01-01

    In a volume reduction process for the decontamination of contained soil, the performance degradation of a filter press is expected owing to material deterioration under high-dose irradiation. Eleven-stock selection of candidate materials including polymers, fibers and rubbers for the filter press was conducted to achieve a high performance of volume reduction of contaminated soil and the following results were derived. Crude rubber and nylon were selected as prime candidates for packing, diaphragm and filter plate materials. Polyethylene was also selected as a prime candidate for the filter cloth material. (author)

  2. Buprenorphine – an attractive opioid with underutilized potential in treatment of chronic pain

    Directory of Open Access Journals (Sweden)

    Khanna IK

    2015-12-01

    Full Text Available Ish K Khanna, Sivaram PillarisettiNeuroPn Therapeutics, Alpharetta, GA, USAAbstract: Despite proven clinical utility, buprenorphine has not been used widely for the treatment of chronic pain. Questions about “ceiling effect” or bell-shaped curve observed for analgesia in preclinical studies and potential withdrawal issues on combining with marketed µ-agonists continue to hinder progress in expanding full potential of buprenorphine in the treatment of cancer and noncancer pain. Mounting evidence from clinical studies and conclusions drawn by a panel of experts strongly support superior safety and efficacy profile of buprenorphine vs marketed opioids. No ceiling on analgesic effect has been reported in clinical studies. The receptor pharmacology and pharmacokinetics profile of buprenorphine is complex but unique and contributes to its distinct safety and efficacy. The buprenorphine pharmacology also allows it to be combined with other µ-receptor opioids for additivity in efficacy. Transdermal delivery products of buprenorphine have been preferred choices for the management of pain but new delivery options are under investigation for the treatment of both opioid dependence and chronic pain.Keywords: buprenorphine, opioids, opioid dependence, partial agonist, hyperalgesia, neuropathic pain

  3. Physiological and immunological changes following exposure to low versus high-dose ionizing irradiation; comparative analysis with dose rate and cumulative dose

    International Nuclear Information System (INIS)

    Heesun, Kim; Heewon, Jang; Soungyeon, Song; Shinhye, Oh; Cukcheul, Shin; Meeseon, Jeong; Chasoon, Kim; Kwnaghee, Yang; Seonyoung, Nam; Jiyoung, Kim; Youngwoo, Jin; Changyoung, Cha

    2008-01-01

    Full text: While high-dose of ionizing radiation is generally harmful and causes damage to living organisms some reports suggest low-dose of radiation may not be as damaging as previously thought. Despite increasing evidence regarding the protective effect of low-dose radiation, no studies have directly compared the exact dose-response pattern by high- and low-dose of radiation exposed at high-and low-dose rate. This study aims to explore the cellular and molecular changes in mice exposed to low- and high-dose of radiation exposed at low- and high-dose rate. When C57BL/6 mice (Female, 6 weeks) were exposed at high-dose rate, 0.8 Gy/min, no significant change on the level of WBC, RBC, or platelets was observed up to total dose of 0.5 Gy. However, 2 Gy of radiation caused dramatic reduction in the level of white blood cells (WBC) and platelets. This reduction was accompanied by increased DNA damage in hematopoietic environments. The reduction of WBC was mainly due to the reduction in the number of CD4+ T cells and CD19+ B cells. CD8+ T cells and NK cells appeared to be relatively resistant to high-dose of radiation. This change was also accompanied by the reduction of T- and B- progenitor cells in the bone marrow. In contrast, no significant changes of the number of CD4+ T, CD8+ T, NK, and B cells were observed in the spleen of mice exposed at low-dose-rate (0.7 m Gy/h or 3.95 mGy/h) for up to 2 Gy, suggesting that low-dose radiation does not alter cellular distribution in the spleen. Nevertheless, mice exposed to low-dose radiation exhibited elevation of VEGF, MCP-1, IL-4, Leptin, IL-3, and Tpo in the peripheral blood and slight increases in MIP-2, RANTES, and IL-2 in the spleen. This suggests that chronic γ-radiation can stimulate immune function without causing damage to the immune components of the body. Taken together, these data indicate hormesis of low-dose radiation, which could be attributed to the stimulation of immune function. Dose rate rather than total

  4. Association between gene variants and response to buprenorphine maintenance treatment.

    Science.gov (United States)

    Gerra, Gilberto; Somaini, Lorenzo; Leonardi, Claudio; Cortese, Elena; Maremmani, Icro; Manfredini, Matteo; Donnini, Claudia

    2014-01-30

    A variety of studies were addressed to differentiate responders and non-responders to substitution treatment among heroin dependent patients, without conclusive findings. In particular, preliminary pharmacogenetic findings have been reported to predict treatment effectiveness in mental health and substance use disorders. Aim of the present study was to investigate the possible association of buprenorphine (BUP) treatment outcome with gene variants that may affect kappa-opioid receptors and dopamine system function. One hundred and seven heroin addicts (West European, Caucasians) who underwent buprenorphine maintenance treatment were genotyped and classified into two groups (A and B) on the basis of treatment outcome. Non-responders to buprenorphine (group B) have been identified taking into account early drop out, continuous use of heroin, severe behavioral or psychiatric problems, misbehavior and diversion during the 6 months treatment period. No difference was evidenced between responders and non-responders to BUP in the frequency of kappa opioid receptor (OPRK1) 36G>T SNP. The frequency of dopamine transporter (DAT) gene polymorphism (SLC6A3/DAT1), allele 10, was evidently much higher in "non-responder" than in "responder" individuals (64.9% vs. 55.93%) whereas the frequency of the category of other alleles (6, 7 and 11) was higher in responder than in non-responder individuals (11.02% vs. 2.13% respectively). On one hand, the hypothesis that possible gene-related changes in kappa-opioid receptor could consistently affect buprenorphine pharmacological action and clinical effectiveness was not confirmed in our study, at least in relation to the single nucleotide polymorphism 36G>T. On the other hand, the possibility that gene-related dopamine changes could have reduced BUP effectiveness and impaired maintenance treatment outcome was cautiously supported by our findings. DAT1 gene variants such as allele 10, previously reported in association with personality and

  5. Opioid withdrawal, craving, and use during and after outpatient buprenorphine stabilization and taper: a discrete survival and growth mixture model.

    Science.gov (United States)

    Northrup, Thomas F; Stotts, Angela L; Green, Charles; Potter, Jennifer S; Marino, Elise N; Walker, Robrina; Weiss, Roger D; Trivedi, Madhukar

    2015-02-01

    Most patients relapse to opioids within one month of opioid agonist detoxification, making the antecedents and parallel processes of first use critical for investigation. Craving and withdrawal are often studied in relationship to opioid outcomes, and a novel analytic strategy applied to these two phenomena may indicate targeted intervention strategies. Specifically, this secondary data analysis of the Prescription Opioid Addiction Treatment Study used a discrete-time mixture analysis with time-to-first opioid use (survival) simultaneously predicted by craving and withdrawal growth trajectories. This analysis characterized heterogeneity among prescription opioid-dependent individuals (N=653) into latent classes (i.e., latent class analysis [LCA]) during and after buprenorphine/naloxone stabilization and taper. A 4-latent class solution was selected for overall model fit and clinical parsimony. In order of shortest to longest time-to-first use, the 4 classes were characterized as 1) high craving and withdrawal, 2) intermediate craving and withdrawal, 3) high initial craving with low craving and withdrawal trajectories and 4) a low initial craving with low craving and withdrawal trajectories. Odds ratio calculations showed statistically significant differences in time-to-first use across classes. Generally, participants with lower baseline levels and greater decreases in craving and withdrawal during stabilization combined with slower craving and withdrawal rebound during buprenorphine taper remained opioid-free longer. This exploratory work expanded on the importance of monitoring craving and withdrawal during buprenorphine induction, stabilization, and taper. Future research may allow individually tailored and timely interventions to be developed to extend time-to-first opioid use. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Conventional-Dose versus High-Dose Chemotherapy for Relapsed Germ Cell Tumors

    Directory of Open Access Journals (Sweden)

    Deaglan J. McHugh

    2018-01-01

    Full Text Available The majority of metastatic germ cell tumors (GCTs are cured with cisplatin-based chemotherapy, but 20–30% of patients will relapse after first-line chemotherapy and require additional salvage strategies. The two major salvage approaches in this scenario are high-dose chemotherapy (HDCT with autologous stem cell transplant (ASCT or conventional-dose chemotherapy (CDCT. Both CDCT and HDCT have curative potential in the management of relapsed/refractory GCT. However, due to a lack of conclusive randomized trials, it remains unknown whether sequential HDCT or CDCT represents the optimal initial salvage approach, with practice varying between tertiary institutions. This represents the most pressing question remaining for defining GCT treatment standards and optimizing outcomes. The authors review prognostic factors in the initial salvage setting as well as the major studies assessing the efficacy of CDCT, HDCT, or both, describing the strengths and weaknesses that formed the rationale behind the ongoing international phase III “TIGER” trial.

  7. Prehospital high-dose sublingual nitroglycerin rarely causes hypotension.

    Science.gov (United States)

    Clemency, Brian M; Thompson, Jeffrey J; Tundo, Gina N; Lindstrom, Heather A

    2013-10-01

    High-dose intravenous nitroglycerin is a common in-hospital treatment for respiratory distress due to congestive heart failure (CHF) with hypertension. Intravenous (IV) nitroglycerin administration is impractical in the prehospital setting. In 2011, a new regional Emergency Medical Services (EMS) protocol was introduced allowing advanced providers to treat CHF with high-dose oral nitroglycerin. The protocol calls for patients to be treated with two sublingual tabs (0.8 mg) when systolic blood pressure (SBP) was >160 mm Hg, or three sublingual tabs (1.2 mg) when SBP was >200 mm Hg, every five minutes as needed. Hypothesis/Problem To assess the protocol's safety, the incidence of hypotension following prehospital administration of multiple simultaneous nitroglycerin (MSN) tabs by EMS providers was studied. This study was a retrospective cohort study of patients from a single commercial EMS agency over a 6-month period. Records from patients with at least one administration of MSN were reviewed. For each administration, the first documented vital signs pre- and post-administration were compared. Administrations were excluded if pre- or post-administration vital signs were missing. One hundred case-patients had at least one MSN administration by an advanced provider during the study period. Twenty-five case-patients were excluded due to incomplete vital signs. Seventy-five case-patients with 95 individual MSN administrations were included for analysis. There were 65 administrations of two tabs, 29 administrations of three tabs, and one administration of four tabs. The mean change in SBP following MSN was -14.7 mm Hg (SD = 30.7; range, +59 to -132). Three administrations had documented systolic hypotension in the post-administration vital signs (97/71, 78/50 and 66/47). All three patients were over 65 years old, were administered two tabs, had documented improved respiratory status, and had repeat SBP of at least 100. The incidence of hypotension following MSN

  8. High-dose irradiated food: Current progress, applications, and prospects

    Science.gov (United States)

    Feliciano, Chitho P.

    2018-03-01

    Food irradiation as an established and mature technology has gained more attention in the food industry for ensuring food safety and quality. Primarily used for phytosanitary applications, its use has been expanded for developing various food products for varied purposes (e.g. ready-to-eat & ready-to-cook foods, hospital diets, etc.). This paper summarized and analyzed the recent progress and application of high-dose irradiation and discussed its prospects in the field of food product development, its safety and quality.

  9. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  10. Identification of dose-reduction techniques for BWR and PWR repetitive high-dose jobs

    International Nuclear Information System (INIS)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    As a result of concern about the apparent increase in collective radiation dose to workers at nuclear power plants, this project will provide information to industry in preplanning for radiation protection during maintenance operations. This study identifies Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) repetitive jobs, and respective collective dose trends and dose reduction techniques. 3 references, 2 tables

  11. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  12. Physics and quality assurance for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Anderson, Lowell L.

    1995-01-01

    Purpose: To review the physical aspects of high dose rate (HDR) brachytherapy, including commissioning and quality assurance, source calibration and dose distribution measurements, and treatment planning methods. Following the introduction of afterloading in brachytherapy, development efforts to make it 'remote' culminated in 1964 with the near-simultaneous appearance of remote afterloaders in five major medical centers. Four of these machines were 'high dose rate', three employing 60Co and one (the GammaMed) using a single, cable-mounted 192Ir source. Stepping-motor source control was added to the GammaMed in 1974, making it the precursor of modern remote afterloaders, which are now suitable for interstitial as well as intracavitary brachytherapy by virtue of small source-diameter and indexer-accessed multiple channels. Because the 192Ir sources currently used in HDR remote afterloaders are supplied at a nominal air-kerma strength of 11.4 cGy cm2 s-1 (10 Ci), are not collimated in clinical use, and emit a significant fraction (15%) of photons at energies greater than 600 keV, shielding and facility design must be undertaken as carefully and thoroughly as for external beam installations. Licensing requirements of regulatory agencies must be met with respect both to maximum permissible dose limits and to the existence and functionality of safety devices (door interlocks, radiation monitors, etc.). Commissioning and quality assurance procedures that must be documented for HDR remote afterloading relate to (1) machine, applicator, guide-tube, and facility functionality checks, (2) source calibration, (3) emergency response readiness, (4) planning software evaluation, and (5) independent checks of clinical dose calculations. Source calibration checks must be performed locally, either by in-air measurement of air kerma strength or with a well ionization chamber calibrated (by an accredited standards laboratory) against an in-air measurement of air kerma strength for the

  13. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  14. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  15. Clinical application of a OneDose MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast.

    Science.gov (United States)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.

  16. Radiation safety program in a high dose rate brachytherapy facility

    International Nuclear Information System (INIS)

    Rodriguez, L.V.; Hermoso, T.M.; Solis, R.C.

    2001-01-01

    The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. Several accidents, however, have been reported involving high dose-rate brachytherapy system. These events, together with the desire to address the concerns of radiation workers, and the anticipated adoption of the International Basic Safety Standards for Protection Against Ionizing Radiation (IAEA, 1996), led to the development of the radiation safety program at the Department of Radiotherapy, Jose R. Reyes Memorial Medical Center and at the Division of Radiation Oncology, St. Luke's Medical Center. The radiation safety program covers five major aspects: quality control/quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. Measures for evaluation of effectiveness of the program include decreased unnecessary exposures of patients and staff, improved accuracy in treatment delivery and increased department efficiency due to the development of staff vigilance and decreased anxiety. The success in the implementation required the participation and cooperation of all the personnel involved in the procedures and strong management support. This paper will discuss the radiation safety program for a high dose rate brachytherapy facility developed at these two institutes which may serve as a guideline for other hospitals intending to install a similar facility. (author)

  17. Dosimetric properties of commercial glasses and sand for high doses

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines

    2004-01-01

    Commercial glasses (transparent and colored) produced by Cebrace, Brazil, Sao Paulo, and sand samples of different Brazilian beaches were studied, due to their low cost and easy handling, to verify the possibility of their use in high dose dosimetry. The main dosimetric characteristics were determined using a densitometer, a spectrophotometer, a thermoluminescent (TL) reader and an electronic paramagnetic resonance system. The gamma irradiations were carried out using a Gamma-Cell 220 and a panoramic source ( 60 Co) of IPEN. An optical absorption band was observed at 420 nm in the glass samples. The TL glow curves presented peaks at 205 deg C, 135 deg C, 150 deg C and 145 deg C for the transparent, bronze, brown and green glass samples, respectively. All EPR spectra of the glasses showed Fe 3+ characteristic signals at g = 4.27 and 2.01. The gamma irradiated sand samples presented two peaks at 110 deg C and 170 deg C and an EPR signal at g= 1.999. However, these materials present a pronounced thermal fading at room temperature after irradiation. With the objective to minimize this thermal fading, both glass and sand samples were submitted to different pre- and post-irradiation thermal treatments. The glass and sand samples showed the possibility of utilization for high dose dosimetry and as Yes/No irradiation detectors. (author)

  18. Audits in high dose rate brachytherapy in Brazil

    International Nuclear Information System (INIS)

    Marechal, M.H.; Rosa, L.A.; Velasco, A.; Paiva, E. de; Goncalves, M.; Castelo, L.C.

    2002-01-01

    The lack of well established dosimetry protocols for HDR sources is a point of great concern regarding the uniformity of procedures within a particular country. The main objective of this paper is to report the results of an implementation of the audit program in dosimetry of high dose rate brachytherapy sources used by the radiation therapy centers in Brazil. In Brazil, among 169 radiotherapy centers, 35 have HDR brachytherapy systems. This program started in August 2001 and until now eight radiotherapy services were audited. The audit program consists of the visit in loco to each center and the evaluation of the intensity of the source with a well type chamber specially design for HDR 192 Ir sources. The measurements was carried out with a HDR1000PLUS Brachytherapy Well Type Chamber and a MAX 4000 Electrometer, both manufactured by Standard Imaging Inc. The chamber was calibrated in air kerma strength by the Accredited Dosimetry Calibration Laboratory, Department of Medical Physics, University of Wisconsin in the USA. The same chamber was calibrated in Brazil using a 192 lr high dose rate source whose intensity was determined by 60 Co gamma rays and 250 kV x rays interpolation methodology. The Nk of 60 Co and 250 kV x rays were provided by the Brazilian National Standard Laboratory for Ionizing Radiation (LMNRI)

  19. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-01-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  20. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-10-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  1. High dose rate versus medium dose rate intraluminal brachytherapy in inoperable esophageal carcinoma

    International Nuclear Information System (INIS)

    Langendijk, J.; Jager, J.; Jong, J. de; Rijken, J.; Pannebakker, M.

    1996-01-01

    Introduction: The purpose of this study was to compare the results of medium dose rate (MDR) intraluminal brachytherapy (ILBT) and high dose rate (HDR) ILBT in patients with inoperable esophageal carcinoma, with regard to dysphagia, complication rate and survival. Material and methods: Included were 114 patients with inoperable esophageal cancer who were treated with a single session of ILBT. In all cases a single dose of 15 Gy was administered, calculated at a 1 cm radius. Forty-eight patients were treated with MDR ( 137 Cs)ILBT. In June 1990 MDR was replaced by HDR and from then 66 patients were treated with HDR ( 192 Ir). Dysphagia was prospectively scored using a 5-point scale at 6 weeks, 3, 6, 9 and 12 months. Results: No significant differences were noted between the two groups with regard to pretreatment variables. In patients treated with MDR-ILBT improvement of swallowing ability was noted in 30 out of 42 evaluable patients (71%), no change in 9 (21%) and progression of dysphagia in 3 patients (8%), as compared to 34 out of 59 evaluable patients (58%), 16 (27%) and 6 (15%) resp. in de HDR-ILBT group. In the latter category, progression of dysphagia was caused by fistulae in 2 patients. The differences were not significant (ns). Additional treatment in case of recurrent or persistent dysphagia was needed in 50% of the cases in the MDR-ILBT group as compared to 41% in the HDR-ILBT group (ns). The median survival of the MDR-ILBT group was 3.9 months as compared to 4.3 months in the HDR-ILBT group (ns). In 2 patients (4%) treated with MDR-ILBT bronchio-oesphageal fistulae developed at 6 weeks and 2 months. In the HDR-ILBT group fistulae were noted in 7 cases (11%) at 2 weeks, 4 weeks, 2, 3, 3, 4 and 9 months (ns). In all of these cases persistent of recurrent tumour was present. Conclusions: No significant differences were noted with regard to palliation of dysphagia, survival and complication rate between MDR-ILBT and HDR-ILBT in the management of esophageal

  2. High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

    International Nuclear Information System (INIS)

    Ghadjar, Pirus; Bojaxhiu, Beat; Simcock, Mathew; Terribilini, Dario; Isaak, Bernhard; Gut, Philipp; Wolfensberger, Patrick; Brömme, Jens O.; Geretschläger, Andreas; Behrensmeier, Frank; Pica, Alessia; Aebersold, Daniel M.

    2012-01-01

    Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3–23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

  3. High Dose-Rate Versus Low Dose-Rate Brachytherapy for Lip Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ghadjar, Pirus, E-mail: pirus.ghadjar@insel.ch [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Bojaxhiu, Beat [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland); Simcock, Mathew [Swiss Group for Clinical Cancer Research Coordinating Center, Bern (Switzerland); Terribilini, Dario; Isaak, Bernhard [Division of Medical Radiation Physics, Inselspital, Bern University Hospital, and University of Bern, Bern (Switzerland); Gut, Philipp; Wolfensberger, Patrick; Broemme, Jens O.; Geretschlaeger, Andreas; Behrensmeier, Frank; Pica, Alessia; Aebersold, Daniel M. [Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern (Switzerland)

    2012-07-15

    Purpose: To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer. Methods and Materials: One hundred and three patients with newly diagnosed squamous cell carcinoma of the lip were treated between March 1985 and June 2009 either by HDR (n = 33) or LDR brachytherapy (n = 70). Sixty-eight patients received brachytherapy alone, and 35 received tumor excision followed by brachytherapy because of positive resection margins. Acute and late toxicity was assessed according to the Common Terminology Criteria for Adverse Events 3.0. Results: Median follow-up was 3.1 years (range, 0.3-23 years). Clinical and pathological variables did not differ significantly between groups. At 5 years, local recurrence-free survival, regional recurrence-free survival, and overall survival rates were 93%, 90%, and 77%. There was no significant difference for these endpoints when HDR was compared with LDR brachytherapy. Forty-two of 103 patients (41%) experienced acute Grade 2 and 57 of 103 patients (55%) experienced acute Grade 3 toxicity. Late Grade 1 toxicity was experienced by 34 of 103 patients (33%), and 5 of 103 patients (5%) experienced late Grade 2 toxicity; no Grade 3 late toxicity was observed. Acute and late toxicity rates were not significantly different between HDR and LDR brachytherapy. Conclusions: As treatment for lip cancer, HDR and LDR brachytherapy have comparable locoregional control and acute and late toxicity rates. HDR brachytherapy for lip cancer seems to be an effective treatment with acceptable toxicity.

  4. Very early disengagement and subsequent re-engagement in primary care Office Based Opioid Treatment (OBOT) with buprenorphine.

    Science.gov (United States)

    Hui, David; Weinstein, Zoe M; Cheng, Debbie M; Quinn, Emily; Kim, Hyunjoong; Labelle, Colleen; Samet, Jeffrey H

    2017-08-01

    Patients with opioid use disorder often require multiple treatment attempts before achieving stable recovery. Rates of disengagement from buprenorphine are highest in the first month of treatment and termination of buprenorphine therapy results in return to use rates as high as 90%. To better characterize these at-risk patients, this study aims to describe: 1) the frequency and characteristics of patients with very early disengagement (≤1month) from Office Based Opioid Treatment (OBOT) with buprenorphine and 2) the frequency and characteristics of patients who re-engage in care at this same OBOT clinic within 2years, among the subset of very early disengagers. This is a retrospective cohort study of adult patients enrolled in a large urban OBOT program. Descriptive statistics were used to characterize the sample and the proportion of patients with very early (≤1month) disengagement and their re-engagement. Multivariable logistic regression models were used to identify patient characteristics associated with the outcomes of very early disengagement and re-engagement. Potential predictors included: sex, age, race/ethnicity, education, employment, opioid use history, prior substance use treatments, urine drug testing, and psychiatric diagnoses. Overall, very early disengagement was unusual, with only 8.4% (104/1234) of patients disengaging within the first month. Among the subset of very early disengagers with 2years of follow-up, the proportion who re-engaged with this OBOT program in the subsequent 2years was 11.9% (10/84). Urine drug test positive for opiates within the first month (AOR: 2.01, 95% CI: 1.02-3.93) was associated with increased odds of very early disengagement. Transferring from another buprenorphine prescriber (AOR: 0.09, 95% CI: 0.01-0.70) was associated with decreased odds of very early disengagement. No characteristics were significantly associated with re-engagement. Early disengagement is uncommon; however, continued opioid use appeared to

  5. Biological dose estimation and comet analysis of the victims in a high dose 60Co radiation accident

    International Nuclear Information System (INIS)

    Chen Ying; Liu Xiulin; Luo Yisheng; Li You; Yao Bo

    2007-01-01

    Objective: To explore the methods of chromosome preparation in human peripheral blood and bone marrow after very high dose exposure and fit the dose-response curve of dicentrics and tings in the range of high doses over 6 Gy for estimating biological dose and detecting DNA damage in the victims of '10.21' accident. Methods: The samples of peripheral blood and bone marrow in 2 victims were collected to prepare chromosome mataphases and dicentrics (multicentrics) + rings were counted. The dose-response curve and equation of human blood irradiated between 6-22 Gy in vitro were established and applied to assess biological dose of 2 victims. In addition, their DNA damages were tested by alkaline single cell gel electrophoresis. Results: The dicentric + ring numbers of 4.47 per cell in victims B's peripheral blood lymphocytes and 9.15 per cell in victim A's bone marrow who had no mitosis in peripheral blood cell. The whole body average doses of victims B and A estimated by 6-22 Gy equation arrived at 9.4 Gy and 19.5 Gy, respectively. The serious DNA damages were expressed by small head and large tail comet figures. Conclusions: The biological doses of 2 victims estimated by 6-22 Gy dose-response curve have reached the levels of extreme grave bone marrow and intestinal ARS, respectively. (authors)

  6. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  7. Shelf-stable food through high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Placek, V. E-mail: pla@ujv.cz; Svobodova, V.; Bartonicek, B.; Rosmus, J.; Camra, M

    2004-10-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75 deg. C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30 deg. C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Rez 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO{sub x}-containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested.

  8. High-dose processing and application to Korean space foods

    Energy Technology Data Exchange (ETDEWEB)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kim, Jae-Hun [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Byun, Myung-Woo [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kang, Sang-Wook; Choi, Gi-Hyuk [Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Lee, Ju-Woon [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of)], E-mail: sjwlee@kaeri.re.kr

    2009-07-15

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods (Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 {sup o}C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  9. Shelf-stable food through high dose irradiation

    International Nuclear Information System (INIS)

    Placek, V.; Svobodova, V.; Bartonicek, B.; Rosmus, J.; Camra, M.

    2004-01-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75 deg. C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30 deg. C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Rez 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO x -containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested

  10. High dose rate brachytherapy for the palliation of malignant dysphagia

    International Nuclear Information System (INIS)

    Homs, Marjolein Y.V.; Eijkenboom, Wilhelmina M.H.; Coen, Veronique L.M.A.; Haringsma, Jelle; Blankenstein, Mark van; Kuipers, Ernst J.; Siersema, Peter D.

    2003-01-01

    Background and purpose: High dose rate (HDR) brachytherapy is a commonly used palliative treatment for esophageal carcinoma. We evaluated the outcome of HDR brachytherapy in patients with malignant dysphagia. Material and methods: A retrospective analysis over a 10-year period was performed of 149 patients treated with HDR brachytherapy, administered in one or two sessions, at a median dose of 15 Gy. Patients were evaluated for functional outcome, complications, recurrent dysphagia, and survival. Results: At 6 weeks after HDR brachytherapy, dysphagia scores had improved from a median of 3 to 2 (n=104; P<0.001), however, dysphagia had not improved in 51 (49%) patients. Procedure-related complications occurred in seven (5%) patients. Late complications, including fistula formation or bleeding, occurred in 11 (7%) patients. Twelve (8%) patients experienced minor retrosternal pain. Median survival of the patients was 160 days with a 1-year survival rate of 15%. Procedure-related mortality was 2%. At follow-up, 55 (37%) patients experienced recurrent dysphagia. In 34 (23%) patients a metal stent was placed to relieve persistent or recurrent dysphagia. Conclusion: HDR brachytherapy is a moderately effective treatment for the palliation of malignant dysphagia. The incidence of early major complications is low, however, persistent and recurrent dysphagia occur frequently, and require often additional treatment

  11. High-dose processing and application to Korean space foods

    Science.gov (United States)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il; Kim, Jae-Hun; Byun, Myung-Woo; Kang, Sang-Wook; Choi, Gi-Hyuk; Lee, Ju-Woon

    2009-07-01

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods ( Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 °C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  12. Tungsten and carbon surface change under high dose plasma exposure

    International Nuclear Information System (INIS)

    Martynenko, Y.V.; Khripunov, B.I.; Petrov, V.B.

    2009-01-01

    Study of surface composition dynamics has been made on the LENTA linear plasma simulator. Experiments have been made on tungsten and carbon materials subjected to steady-state plasma exposure. The achieved ion doses on the surface were 10 21 ion cm -2 . WL 10 tungsten containing 1% of La2O3 oxide and titanium-doped graphite RG-T were studied. The following experimental conditions were varied in these experiments: energy of ions, surface temperature, working gas. Irradiations of tungsten WL 10 were executed in deuterium plasma at low ion energies (about 20 eV) and at 200 eV for temperatures below 340 K. Graphite RG-T was exposed at 1300 K. Elevated surface temperature (about 1050K) was also characteristic of experiments on tungsten sample under nitrogen plasma impact (simulated inter-ELMs condition). Surface microstructure modification has been observed and surface composition changes were found on the materials showing influence of high dose plasma irradiations on element redistribution in the near surface layers. (author)

  13. High-dose processing and application to Korean space foods

    International Nuclear Information System (INIS)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il; Kim, Jae-Hun; Byun, Myung-Woo; Kang, Sang-Wook; Choi, Gi-Hyuk; Lee, Ju-Woon

    2009-01-01

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods (Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 o C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  14. Concept and computation of radiation dose at high energies

    International Nuclear Information System (INIS)

    Sarkar, P.K.

    2010-01-01

    Computational dosimetry, a subdiscipline of computational physics devoted to radiation metrology, is determination of absorbed dose and other dose related quantities by numbers. Computations are done separately both for external and internal dosimetry. The methodology used in external beam dosimetry is necessarily a combination of experimental radiation dosimetry and theoretical dose computation since it is not feasible to plan any physical dose measurements from inside a living human body

  15. Comment on "a comparison of buprenorphine + naloxone to buprenorphine and methadone in the treatment of opioid dependence during pregnancy: maternal and neonatal outcomes".

    Science.gov (United States)

    Newman, Robert G; Gevertz, Susan G

    2013-01-01

    In a recent article, Lund et al sought to compare maternal and neonatal outcomes of various treatment regimens for opioid dependence during pregnancy.1 In their background, discussion the authors state that "In the United States buprenorphine plus naloxone [Suboxone(®)] … has been the preferred form of prescribed buprenorphine due to its reduced abuse liability relative to buprenorphine alone [Subutex(®)]." This claim is certainly consistent with the view of the firm that has manufactured and sold both products, Reckitt Benckiser. In September of 2011, the company announced that it was "… discontinuing distribution and sale of Subutex(®) tablets as we believe that mono product (product containing buprenorphine alone with no naloxone) creates a greater risk of misuse, abuse and diversion …".2 Supporting evidence for the alleged "reduced abuse liability" appears to be lacking, however, and evidence cannot be located in the two references cited by Dr. Lund and his co-authors, which in fact are silent on the subject of abuse potential.3,4 In contrast, it has been reported that the transition to buprenorphine/naloxone from the mono formulation has been associated with "… no reduction in injection risk behaviors among IDUs."5.

  16. Comment on “A Comparison of Buprenorphine + Naloxone to Buprenorphine and Methadone in the Treatment of Opioid Dependence during Pregnancy: Maternal and Neonatal Outcomes”

    Directory of Open Access Journals (Sweden)

    Robert G. Newman M.D., M.P.H.

    2013-01-01

    Full Text Available In a recent article, Lund et al sought to compare maternal and neonatal outcomes of various treatment regimens for opioid dependence during pregnancy. 1 In their background, discussion the authors state that “In the United States buprenorphine plus naloxone [Suboxone®] … has been the preferred form of prescribed buprenorphine due to its reduced abuse liability relative to buprenorphine alone [Subutex®].” This claim is certainly consistent with the view of the firm that has manufactured and sold both products, Reckitt Benckiser. In September of 2011, the company announced that it was “… discontinuing distribution and sale of Subutex® tablets as we believe that mono product (product containing buprenorphine alone with no naloxone creates a greater risk of misuse, abuse and diversion …”. 2 Supporting evidence for the alleged “reduced abuse liability” appears to be lacking, however, and evidence cannot be located in the two references cited by Dr. Lund and his co-authors, which in fact are silent on the subject of abuse potential. 3 , 4 In contrast, it has been reported that the transition to buprenorphine/naloxone from the mono formulation has been associated with “… no reduction in injection risk behaviors among IDUs.” 5

  17. Training rural practitioners to use buprenorphine; using The Change Book to facilitate technology transfer.

    Science.gov (United States)

    McCarty, Dennis; Rieckmann, Traci; Green, Carla; Gallon, Steve; Knudsen, Jeff

    2004-04-01

    The Opiate Medication Initiative for Rural Oregon Residents trained physicians and counselors in Central and Southwestern Oregon to use buprenorphine and develop service models that supported patient participation in drug abuse counseling. The Change Book from Addiction Technology Transfer Centers was used to structure the change process. Fifty-one individuals (17 physicians, 4 pharmacists, 2 nurse practitioners, and 28 drug abuse counselors and administrators) from seven counties completed the training and contributed to the development of community treatment protocols. A pre-post measure of attitudes and beliefs toward the use of buprenorphine suggested significant improvements in attitude after training, especially among counselors. Eight months after training, 10 of 17 physicians trained had received waivers to use buprenorphine and 29 patients were in treatment with six of the physicians. The Change Book facilitated development of county change teams and structured the planning efforts. The initiative also demonstrated the potential to concurrently train physicians, pharmacists, and counselors on the use of buprenorphine.

  18. Pharmacodynamic and pharmacokinetic evaluation of buprenorphine + samidorphan for the treatment of major depressive disorder.

    Science.gov (United States)

    Ragguett, Renee-Marie; Rong, Carola; Rosenblat, Joshua D; Ho, Roger C; McIntyre, Roger S

    2018-04-01

    Treatment resistant depression (TRD) represents approximately 20% of all individuals receiving care for major depressive disorder. The opioidergic system is identified as a novel target which hitherto has not been sufficiently investigated in adults with TRD. The combination product buprenorphine + samidorphan is an opioid modulatory agent which has demonstrated replicated evidence of efficacy in TRD without abuse liability. Areas covered: Databases Pubmed, Google Scholar and clinicaltrials.gov were searched from inception through December 2017 for clinical trial information, pharmacokinetics, and pharmacodynamics of buprenorphine + samidorphan. Herein we provide a summary of the available information. Eight clinical trials were identified for inclusion, of the eight trials, five trials had available results and are included in detail in our review. Expert opinion: Buprenorphine + samidorphan has demonstrated efficacy in TRD. Extant evidence surrounding the safety and tolerability profile of buprenorphine + samidorphan does not identify any significant safety concerns. Additional studies are needed in order to assess the long-term safety and efficacy of this product.

  19. Buprenorphine vs methadone treatment: A review of evidence in both developed and developing worlds

    Directory of Open Access Journals (Sweden)

    Paul J Whelan

    2012-01-01

    Full Text Available Heroin dependence is a major health and social problem associated with increased morbidity and mortality that adversely affects social circumstances, productivity, and healthcare and law enforcement costs. In the UK and many other Western countries, both methadone and buprenorphine are recommended by the relevant agencies for detoxification from heroin and for opioid maintenance therapy. However, despite obvious benefits due to its unique pharmacotherapy (eg, greatly reduced risk of overdose, buprenorphine has largely failed to overtake methadone in managing opioid addiction. The experience from the developing world (based on data from India is similar. In this article we compare the advantages and disadvantages of the use methadone and buprenorphine for the treatment of opioid addiction from both a developed and developing world perspective; and explore some of the reasons why buprenorphine has not fulfilled the expectations predicted by many in the addictions field.

  20. High-Dose Atomoxetine Treatment of ADHD in Youths with Limited Response to Standard Doses

    Science.gov (United States)

    Kratochvil, Christopher J.; Michelson, David; Newcorn, Jeffrey H.; Weiss, Margaret D.; Busner, Joan; Moore, Rodney J.; Ruff, Dustin D.; Ramsey, Janet; Dickson, Ruth; Turgay, Atilla; Saylor, Keith E.; Luber, Stephen; Vaughan, Brigette; Allen, Albert J.

    2007-01-01

    Objective: To assess the utility and tolerability of higher than standard atomoxetine doses to treat attention-deficit/hyperactivity disorder (ADHD). Method: Two randomized, double-blind trials of atomoxetine nonresponders ages 6 to 16 years were conducted comparing continued treatment with same-dose atomoxetine to treatment using greater than…

  1. Surface sputtering in high-dose Fe ion implanted Si

    International Nuclear Information System (INIS)

    Ishimaru, Manabu

    2007-01-01

    Microstructures and elemental distributions in high-dose Fe ion implanted Si were characterized by means of transmission electron microscopy and Rutherford backscattering spectroscopy. Single crystalline Si(0 0 1) substrates were implanted at 350 deg. C with 120 keV Fe ions to fluences ranging from 0.1 x 10 17 to 4.0 x 10 17 /cm 2 . Extensive damage induced by ion implantation was observed inside the substrate below 1.0 x 10 17 /cm 2 , while a continuous iron silicide layer was formed at 4.0 x 10 17 /cm 2 . It was found that the spatial distribution of Fe projectiles drastically changes at the fluence between 1.0 x 10 17 and 4.0 x 10 17 /cm 2 due to surface sputtering during implantation

  2. High-dose erythropoietin in patients with progressive multiple sclerosis

    DEFF Research Database (Denmark)

    Schreiber, Karen; Magyari, Melinda; Sellebjerg, Finn

    2017-01-01

    BACKGROUND: Erythropoietin (EPO) is a part of an endogenous neuroprotective system in the brain and may address pathophysiological mechanisms in progressive multiple sclerosis (MS). OBJECTIVE: To evaluate a treatment effect of EPO on progressive MS. METHODS: This was a single-center, randomized......, double-blind, placebo-controlled phase 2 trial, in which 52 patients with secondary or primary progressive MS were allocated to treatment with recombinant EPO (48,000 IU) or placebo, administered intravenously 17 times during 24 weeks. Patients had an Expanded Disability Status Score (EDSS) from 4 to 6......: This study provides class II evidence that treatment with high-dose EPO is not an effective treatment in patients with moderately advanced progressive MS....

  3. Safety handling manual for high dose rate remote afterloading system

    International Nuclear Information System (INIS)

    1999-01-01

    This manual is mainly for safety handling of 192 Ir-RALS (remote afterloading system) of high dose rate and followings were presented: Procedure and document format for the RALS therapy and for handling of its radiation source with the purpose of prevention of human errors and unexpected accidents, Procedure for preventing errors occurring in the treatment schedule and operation, and Procedure and format necessary for newly introducing the system into a facility. Consistency was intended in the description with the quality assurance guideline for therapy with small sealed radiation sources made by JASTRO (Japan Society for Therapeutic Radiology and Oncology). Use of the old type 60 Co-RALS was pointed out to be a serious problem remained and its safety handling procedure was also presented. (K.H.)

  4. Pharmacokinetics of high-dose intravenous melatonin in humans

    DEFF Research Database (Denmark)

    Andersen, Lars P H; Werner, Mads U; Rosenkilde, Mette Marie

    2016-01-01

    This crossover study investigated the pharmacokinetics and adverse effects of high-dose intravenous melatonin. Volunteers participated in 3 identical study sessions, receiving an intravenous bolus of 10 mg melatonin, 100 mg melatonin, and placebo. Blood samples were collected at baseline and 0, 60......, 120, 180, 240, 300, 360, and 420 minutes after the bolus. Quantitative determination of plasma melatonin concentrations was performed using a radioimmunoassay technique. Pharmacokinetic parameters were estimated by a compartmental pharmacokinetic analysis. Adverse effects included assessments...... of sedation and registration of other symptoms. Sedation, evaluated as simple reaction times, was measured at baseline and 120, 180, 300, and 420 minutes after the bolus. Twelve male volunteers completed the study. Median (IQR) Cmax after the bolus injections of 10 mg and 100 mg of melatonin were 221...

  5. Calibration of {sup 192}Ir high dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Marechal, M H [Instituto de Radioprotecao e Dozimetria, Rio de Jainero (Brazil); Almeida, C.E. de [Laboratorio de Ciencias Radiologicas, UERL, Rio de Janeiro (Brazil); Sibata, C H [Roswell Park Cancer Inst., Buffalo, NY (United States)

    1996-08-01

    A method for calibration of high dose rate sources used in afterloading brachytherapy systems is described. The calibration for {sup 192}Ir is determined by interpolating {sup 60}Co gamma-rays and 250 kV x-rays calibration factors. All measurements were done using the same build up caps as described by Goetsch et al and recommended by AAPM. The attenuation correction factors were determined to be 0.9903, 0.9928 and 0.9993 for {sup 192}Ir, {sup 60}Co and 250 kV x-ray, respectively. A wall + cap thickness of 0.421 g.cm{sup -2} is recommended for all measurements to ensure electronic equilibrium for {sup 60}Co and {sup 192}Ir gamma-ray beams. A mathematical formalism is described for determination of (N{sub x}){sub Ir}. (author). 5 refs, 1 fig.

  6. 192Ir high dose rate (HDR) interstitial brain implant: optimisation

    International Nuclear Information System (INIS)

    Tyagi, Anuj; Singh, Dinesh; Chitra, S.; Gupta, J.P.

    2001-01-01

    The new modality of stepping source dosimetry system (SSDs) illustrates a remarkable improvement in attaining the uniform and homogeneous dose distribution within the target volume. The technique enables the physicist to correct for a certain amount of misplacement or curvature of implant geometry. The short course of brachytherapy provides good palliation in terms of functional improvements with low and acceptable toxicity in high-grade glioma. With continual refinements of the technique, brachytherapy performed by a skilled brachytherapy team offers an opportunity to improve patient survival and quality of life. Since 1997, micro selectron HDR 192 Ir treatments are done including gynecological, oesophageal, breast, surface mould, soft tissue sarcoma (STS) and brain in our hospital. In this paper, procedure of interstitial brain implant in glioma as implant technique, simulation and treatment planning will be discussed

  7. High dose rate brachytherapy for superficial cancer of the esophagus

    International Nuclear Information System (INIS)

    Maingon, Philippe; D'Hombres, Anne; Truc, Gilles; Barillot, Isabelle; Michiels, Christophe; Bedenne, Laurent; Horiot, Jean Claude

    2000-01-01

    Purpose: We analyzed our experience with external radiotherapy, combined modality treatment, or HDR brachytherapy alone to limited esophageal cancers. Methods and Materials: From 1991 to 1996, 25 patients with limited superficial esophagus carcinomas were treated by high dose rate brachytherapy. The mean age was 63 years (43-86 years). Five patients showed superficial local recurrence after external radiotherapy. Eleven patients without invasion of the basal membrane were staged as Tis. Fourteen patients with tumors involving the submucosa without spreading to the muscle were staged as T1. Treatment consisted of HDR brachytherapy alone in 13 patients, external radiotherapy and brachytherapy in 8 cases, and concomitant chemo- and radiotherapy in 4 cases. External beam radiation was administered to a total dose of 50 Gy using 2 Gy daily fractions in 5 weeks. In cases of HDR brachytherapy alone (13 patients), 6 applications were performed once a week. Results: The mean follow-up is 31 months (range 24-96 months). Twelve patients received 2 applications and 13 patients received 6 applications. Twelve patients experienced a failure (48%), 11/12 located in the esophagus, all of them in the treated volume. One patient presented an isolated distant metastasis. In the patients treated for superficial recurrence, 4/5 were locally controlled (80%) by brachytherapy alone. After brachytherapy alone, 8/13 patients were controlled (61%). The mean disease-free survival is 14 months (1-36 months). Overall survival is 76% at 1 year, 37% at 2 years, and 14% at 3 years. Overall survival for Tis patients is 24% vs. 20% for T1 (p 0.83). Overall survival for patients treated by HDR brachytherapy alone is 43%. One patient presented with a fistula with local failure after external radiotherapy and brachytherapy. Four stenosis were registered, two were diagnosed on barium swallowing without symptoms, and two required dilatations. Conclusion: High dose rate brachytherapy permits the treating

  8. "Time sequential high dose of Cytarabine in acute myelocytic leukemia "

    Directory of Open Access Journals (Sweden)

    Ghavamzadeh A

    2003-05-01

    Full Text Available Given preliminary evidence of timed, sequential chemotherapy of high dose cytosine arabinoside the current study was initiated to assess the side effects and efficacy of this regimen in patients with newly acute myelocytic leukemia (AML. Nineteen adults who referred to Hematology-Oncology and Bone Marrow Transplantation (BMT research center of Tehran University of Medical Sciences were enrolled in a trial from Aug 1999 to Nov 2000. All patients had a Karnofski classification above 60%. At this time induction therapy consisted of daunorubicin or idarubicin given at a dose of 60 mg/m² and 12 mg/m² IV respectively on days 1-3, and cytarabine (Ara-C 100 mg/m² intravenously by continuous infusion on days 1-7, followed by Ara-C 1000 mg/m² given on day 8-10 every 12 hours by IV infusion. Consolidation therapy started after 35th day. Of 19 fully evaluable patients, 10 patients achieved a complete remission, whereas 36.6% patients succumbed to death due to regeneration failure. The clinical data show that the overall survival rate from diagnosis 55.5% (95% CI, 30.8-78.5 at 6 months for the entire cohort of the patients. Disease free survival is also 50% (95% CI, 26-74. Mean duration of death due to treatment was 20 days (range 17-29 after beginning the regimen. Presenting WBC counts, French-American-British (FAB classification, sex and age were not useful prognostic variables. Fever, diarrhea, nausea and vomiting and GI hemorrhage were seen in 19, 6, 4, 7 patients respectively. It seems the 3+7+3 regimen is a promising approach for the AML patients regarding to high complete remission rate, but more supportive care should be considered. Furthermore any, benefit in long-term outcome can’t be determined regardless to the choice of post remission therapy (e.g., GCSF, appropriate antibiotics and etc.

  9. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tome, Wolfgang A. [Department of Human Oncology, University of Wisconsin-Madison, WI, 53792 (United States); Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC 3002 (Australia) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Human Oncology, University of Wisconsin-Madison, WI 53792 (United States); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia) and Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Einstein Institute of Oncophysics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York 10461 (United States) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2012-08-15

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  10. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tomé, Wolfgang A.

    2012-01-01

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed “Super Sampling” involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  11. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  12. Buprenorphine from detox and beyond: preliminary evaluation of a pilot program to increase heroin dependent individuals' engagement in a full continuum of care.

    Science.gov (United States)

    Donovan, Dennis M; Knox, Patricia C; Skytta, Jenny A F; Blayney, Jessica A; DiCenzo, Jessica

    2013-04-01

    Absence of successful transition to post-detoxification treatment leads to high rates of relapse among detoxified heroin users. The present study evaluated a pilot buprenorphine treatment program (BTP). Heroin dependent individuals were inducted onto buprenorphine/naloxone in detox, maintained while transitioning through an intensive inpatient program (IIP), and gradually tapered off medication over 5 months of outpatient (OP) treatment. Compared to programmatic indicators of treatment engagement in the year prior to BTP implementation, referrals from detox to IIP, entry into and completion of IIP and subsequent OP, and days in OP treatment increased substantially. BTP completers, compared to non-completers, viewed abstinence as more difficult and as requiring more assistance to achieve, were less likely to be current cocaine and alcohol users or to have relapsed during the course of treatment. Although preliminary and in need of replication, initial adjunctive use of buprenorphine in an abstinence-based continuum of care may improve post-detoxification treatment entry, engagement, and completion. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  14. The Comparison of Two Types of Treatment (High Dose and Low Dose IVIG in Children with GBS in Mofid Hospital

    Directory of Open Access Journals (Sweden)

    Parvaneh Karim-Zadeh

    2003-12-01

    Full Text Available Objective: Acute inflammatory demyelinating peripheral neuropathy (Guillain-Barre-Syndrome is by far the most common cause of immune–mediated peripheral nerve disease in children and with the near disappearance of poliomyelitis, is responsible for the great majority of cases of acute flaccid paralysis. Several controlled studies have done with corticosteroids, plasma pheresis and IVIG in pediatric patients. IVIG treatment can be done in two types of treatment: 1- High dose that means 1gr/kg/day for 2 days. 2- Low dose that means 400mg/kg/day for 5 days. Several studies in other countries have shown faster rate of recovery in patients who received total dose of IVIG in 2 days as opposed to 5 days. Materials & Methods: Because we have not any study about this two types of treatment in IRAN we decided to comparison this two types of IVIG treatment. So the patients that referred to Mofid children hospital for weakness and we diagnosed GBS (with history, physical examination, laboratories and EMG-NCV are divided in two groups: 1- High dose IVIG treatment (experimental group. 2- Low dose IVIG treatment (control group Then the results evaluated. Results: Our findings included that in high dose IVIG therapy we have faster rate of recovery and the Hospital stay is shorter than low dose IVIG-therapy. Also in this type of treatment “because the patients cure faster” , so complications are decreased in them. In the group of high dose IVIG therapy, lower and upper extremities weakness decreased in time. Conclusion: We did not receive any relationship between side effects of drugs and the type of treatment. The relationship between high dose IVIG therapy and drug side effects was not significant.

  15. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  16. Pharmacokinetics of oral transmucosal and intramuscular dexmedetomidine combined with buprenorphine in cats.

    Science.gov (United States)

    Porters, N; de Rooster, H; Bosmans, T; Baert, K; Cherlet, M; Croubels, S; De Backer, P; Polis, I

    2015-04-01

    Plasma concentrations and pharmacokinetics of dexmedetomidine and buprenorphine after oral transmucosal (OTM) and intramuscular (i.m.) administration of their combination in healthy adult cats were compared. According to a crossover protocol (1-month washout), a combination of dexmedetomidine (40 μg/kg) and buprenorphine (20 μg/kg) was given OTM (buccal cavity) or i.m. (quadriceps muscle) in six female neutered cats. Plasma samples were collected through a jugular catheter during a 24-h period. Plasma dexmedetomidine and buprenorphine concentrations were determined by liquid chromatography-tandem mass spectrometry. Plasma concentration-time data were fitted to compartmental models. For dexmedetomidine and buprenorphine, the area under the plasma concentration-time curve (AUC) and the maximum plasma concentrations (Cmax ) were significantly lower following OTM than following i.m. administration. For buprenorphine, time to reach Cmax was also significantly longer after OTM administration than after i.m. injection. Data suggested that dexmedetomidine (40 μg/kg) combined with buprenorphine (20 μg/kg) is not as well absorbed from the buccal mucosa site as from the intramuscular injection site. © 2014 John Wiley & Sons Ltd.

  17. Development of a radioimmunoassay for the determination of buprenorphine in biological samples

    International Nuclear Information System (INIS)

    Debrabandere, L.; Boven, M. Van; Daenens, P.

    1993-01-01

    The development of a specific and sensitive radioimmunoassay for the detection of buprenorphine in urine samples is described. With minor adjustments, the assay was also applied to the analysis for buprenorphine in plasma samples. The 2-diazobenzoic acid derivative of buprenorphine has been prepared as a hapten. The immunization of rabbits with the hapten-bovine serum albumin conjugate resulted in the production of antibodies, which cross-reacted with N-dealkylbuprenophine up to about the 90% level. The antibodies showed very low cross-reactivities with the 3-O-glucuronides and with the structural analogue etorphine. The assay was mainly used to prescreen for buprenorphine in urine samples of persons suspected of Temgesic misuse and to determine buprenorphine in plasma samples. A linear calibration graph for buprenorphine was obtained after logit-log regression. The spiking recovery study showed a linear regression. Intra-and inter-assay relative standard deviations were -1 (Student's t-distribution, p 0.01, degrees of freedom = 8). (Author)

  18. A randomized controlled trial of prison-initiated buprenorphine: prison outcomes and community treatment entry.

    Science.gov (United States)

    Gordon, Michael S; Kinlock, Timothy W; Schwartz, Robert P; Fitzgerald, Terrence T; O'Grady, Kevin E; Vocci, Frank J

    2014-09-01

    Buprenorphine is a promising treatment for heroin addiction. However, little is known regarding its provision to pre-release prisoners with heroin dependence histories who were not opioid-tolerant, the relative effectiveness of the post-release setting in which it is provided, and gender differences in treatment outcome in this population. This is the first randomized clinical trial of prison-initiated buprenorphine provided to male and female inmates in the US who were previously heroin-dependent prior to incarceration. A total of 211 participants with 3-9 months remaining in prison were randomized to one of four conditions formed by crossing In-Prison Treatment Condition (received buprenorphine vs. counseling only) and Post-release Service Setting (at an opioid treatment center vs. a community health center). Outcome measures were: entered prison treatment; completed prison treatment; and entered community treatment 10 days post-release. There was a significant main effect (p=.006) for entering prison treatment favoring the In-Prison buprenorphine Treatment Condition (99.0% vs. 80.4%). Regarding completing prison treatment, the only significant effect was Gender, with women significantly (pPrison buprenorphine Treatment Condition (47.5% vs. 33.7%). Buprenorphine appears feasible and acceptable to prisoners who were not opioid-tolerant and can facilitate community treatment entry. However, concerns remain with in-prison treatment termination due to attempted diversion of medication. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Urethral stricture following high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Sullivan, Lisa; Williams, Scott G.; Tai, Keen Hun; Foroudi, Farshad; Cleeve, L.; Duchesne, Gillian M.

    2009-01-01

    Purpose: To evaluate the incidence, timing, nature and outcome of urethral strictures following high dose rate brachytherapy (HDRB) for prostate carcinoma. Methods and materials: Data from 474 patients with clinically localised prostate cancer treated with HDRB were analysed. Ninety percent received HDRB as a boost to external beam radiotherapy (HDRBB) and the remainder as monotherapy (HDRBM). Urethral strictures were graded according to the Common Terminology Criteria for Adverse Events v3.0. Results: At a median follow-up of 41 months, 38 patients (8%) were diagnosed with a urethral stricture (6-year actuarial risk 12%). Stricture location was bulbo-membranous (BM) urethra in 92.1%. The overall actuarial rate of grade 2 or more BM urethral stricture was estimated at 10.8% (95% CI 7.0-14.9%), with a median time to diagnosis of 22 months (range 10-68 months). All strictures were initially managed with either dilatation (n = 15) or optical urethrotomy (n = 20). Second line therapy was required in 17 cases (49%), third line in three cases (9%) and 1 patient open urethroplasty (grade 3 toxicity). Predictive factors on multivariate analysis were prior trans-urethral resection of prostate (hazard ratio (HR) 2.81, 95% CI 1.15-6.85, p = 0.023); hypertension (HR 2.83, 95% CI 1.37-5.85, p = 0.005); and dose per fraction used in HDR (HR for 1 Gy increase per fraction 1.33, 95% CI 1.08-1.64, p = 0.008). Conclusions: BM urethral strictures are the most common late grade 2 or more urinary toxicity following HDR brachytherapy for prostate cancer. Most are manageable with minimally invasive procedures. Both clinical and dosimetric factors appear to influence the risk of stricture formation.

  20. Dosing algorithm to target a predefined AUC in patients with primary central nervous system lymphoma receiving high dose methotrexate.

    Science.gov (United States)

    Joerger, Markus; Ferreri, Andrés J M; Krähenbühl, Stephan; Schellens, Jan H M; Cerny, Thomas; Zucca, Emanuele; Huitema, Alwin D R

    2012-02-01

    There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h. A population covariate model from a pooled dataset of 131 patients receiving HDMTX was used to simulate concentration-time curves of 10,000 patients and test the efficacy of a dosing algorithm based on 24 h MTX plasma concentrations to target the prespecified AUC(MTX) . These data simulations included interindividual, interoccasion and residual unidentified variability. Patients received a total of four simulated cycles of HDMTX and adjusted MTX dosages were given for cycles two to four. The dosing algorithm proposes MTX dose adaptations ranging from +75% in patients with MTX C(24) 12 µmol l(-1). The proposed dosing algorithm resulted in a marked improvement of the proportion of patients within the AUC(MTX) target between 1000 and 1100 µmol l(-1) h (11% with standard MTX dose, 35% with the adjusted dose) and a marked reduction of the interindividual variability of MTX exposure. A simple and practical dosing algorithm for HDMTX has been developed based on MTX 24 h plasma concentrations, and its potential efficacy in improving the proportion of patients within a prespecified target AUC(MTX) and reducing the interindividual variability of MTX exposure has been shown by data simulations. The clinical benefit of this dosing algorithm should be assessed in patients with primary central nervous system lymphoma (PCNSL). © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.

  1. Opioid receptor imaging and displacement studies with [6-O-[11C]methyl]buprenorphine in baboon brain

    International Nuclear Information System (INIS)

    Galynker, Igor; Schlyer, David J.; Dewey, Stephen L.; Fowler, Joanna S.; Logan, Jean; Gatley, S. John; MacGregor, Robert R.; Ferrieri, Richard A.; Holland, M. J.; Brodie, Jonathan; Simon, Eric; Wolf, Alfred P.

    1996-01-01

    Buprenorphine (BPN) is a mixed opiate agonist-antagonist used as an analgesic and in the treatment of opiate addiction. We have used [6-O-[ 11 C]methyl]buprenorphine ([ 11 C]BPN) to measure the regional distribution in baboon brain, the test-retest stability of repeated studies in the same animal, the displacement of the labeled drug by naloxone in vivo, and the tissue distribution in mice. The regional distribution of radioactivity in baboon brain determined with PET was striatum > thalamus > cingulate gyrus > frontal cortex > parietal cortex > occipital cortex > cerebellum. This distribution corresponded to opiate receptor density and to previously published data (37). The tracer uptake in adult female baboons showed no significant variation in serial scans in the same baboon with no intervention in the same scanning session. HPLC analysis of baboon plasma showed the presence of labeled metabolites with 92% ± 2.2% and 43% ± 14.4% of the intact tracer remaining at 5 and 30 min, respectively. Naloxone, an opiate receptor antagonist, administered 30-40 min after tracer injection at a dose of 1.0 mg/kg i.v., reduced [ 11 C]BPN binding in thalamus, striatum, cingulate gyrus, and frontal cortex to values 0.25 to 0.60 of that with no intervention. There were minimal ( 11 C]BPN can be displaced by naloxone in vivo, and they affirm the feasibility of using this tracer and displacement methodology for short-term kinetics studies with PET. Mouse tissue distribution data were used to estimate the radiation dosimetry to humans. The critical organ was the small intestine, with a radiation dose estimate to humans of 117 nrad/mCi

  2. Opioid receptor imaging and displacement studies with [6-O-[{sup 11}C]methyl]buprenorphine in baboon brain

    Energy Technology Data Exchange (ETDEWEB)

    Galynker, Igor; Schlyer, David J.; Dewey, Stephen L.; Fowler, Joanna S.; Logan, Jean; Gatley, S. John; MacGregor, Robert R.; Ferrieri, Richard A.; Holland, M. J.; Brodie, Jonathan; Simon, Eric; Wolf, Alfred P

    1996-04-01

    Buprenorphine (BPN) is a mixed opiate agonist-antagonist used as an analgesic and in the treatment of opiate addiction. We have used [6-O-[{sup 11}C]methyl]buprenorphine ([{sup 11}C]BPN) to measure the regional distribution in baboon brain, the test-retest stability of repeated studies in the same animal, the displacement of the labeled drug by naloxone in vivo, and the tissue distribution in mice. The regional distribution of radioactivity in baboon brain determined with PET was striatum > thalamus > cingulate gyrus > frontal cortex > parietal cortex > occipital cortex > cerebellum. This distribution corresponded to opiate receptor density and to previously published data (37). The tracer uptake in adult female baboons showed no significant variation in serial scans in the same baboon with no intervention in the same scanning session. HPLC analysis of baboon plasma showed the presence of labeled metabolites with 92% {+-} 2.2% and 43% {+-} 14.4% of the intact tracer remaining at 5 and 30 min, respectively. Naloxone, an opiate receptor antagonist, administered 30-40 min after tracer injection at a dose of 1.0 mg/kg i.v., reduced [{sup 11}C]BPN binding in thalamus, striatum, cingulate gyrus, and frontal cortex to values 0.25 to 0.60 of that with no intervention. There were minimal (< 15%) effects on cerebellum. Naloxone treatment significantly reduced the slope of the Patlak plot in receptor-containing regions. These results demonstrate that [{sup 11}C]BPN can be displaced by naloxone in vivo, and they affirm the feasibility of using this tracer and displacement methodology for short-term kinetics studies with PET. Mouse tissue distribution data were used to estimate the radiation dosimetry to humans. The critical organ was the small intestine, with a radiation dose estimate to humans of 117 nrad/mCi.

  3. Studies of absorbed dose determinations and spatial dose distributions for high energy proton beams

    International Nuclear Information System (INIS)

    Hiraoka, Takeshi

    1982-01-01

    Absolute dose determinations were made with three types of ionization chamber and a Faraday cup. Methane based tissue equivalent (TE) gas, nitrogen, carbon dioxide, air were used as an ionizing gas with flow rate of 10 ml per minute. Measurements were made at the entrance position of unmodulated beams and for a beam of a spread out Bragg peak at a depth of 17.3 mm in water. For both positions, the mean value of dose determined by the ionization chambers was 0.993 +- 0.014 cGy for which the value of TE gas was taken as unity. The agreement between the doses estimated by the ionization chambers and the Faraday cup was within 5%. Total uncertainty estimated in the ionization chamber and the Faraday cup determinations is 6 and 4%, respectively. Common sources of error in calculating the dose from ionization chamber measurements are depend on the factors of ion recombination, W value, and mass stopping power ratio. These factors were studied by both experimentally and theoretically. The observed values for the factors show a good agreement to the predicted one. Proton beam dosimetry intercomparison between Japan and the United States was held. Good agreement was obtained with standard deviation of 1.6%. The value of the TE calorimeter is close to the mean value of all. In the proton spot scanning system, lateral dose distributions at any depth for one spot beam can be simulated by the Gaussian distribution. From the Gaussian distributions and the central axis depth doses for one spot beam, it is easy to calculate isodose distributions in the desired field by superposition of dose distribution for one spot beam. Calculated and observed isodose curves were agreed within 1 mm at any dose levels. (J.P.N.)

  4. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige [Kinki Univ., Atomic Energy Research Institute, Osaka (Japan); Tatsumi, Kusuo [Kinki Univ., Life Science Research Institute, Osaka (Japan); Nakai, Sayaka; Sugahara, Tsutomu [Health Research Foundation, Kyoto (Japan); Yuan Yongling [Labor Hygiene Institute of Hunan Prov. (China); Wei Luxin [Laboratory of Industorial Hygiene, Ministry of Health (China)

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: (1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. (2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  5. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    International Nuclear Information System (INIS)

    Koga, Taeko; Morishima, Hiroshige; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: 1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. 2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  6. Enzymatic assays for detecting lactose and sucrose in urine to reveal intravenous drug abuse with emphasis on buprenorphine.

    Science.gov (United States)

    Keltanen, T; Mariottini, C; Walta, A M; Rahikainen, A L; Ojanperä, I

    2017-06-01

    Buprenorphine and methadone are commonly used medications for opioid maintenance treatment (OMT), using sublingual and oral administration, respectively. Although beneficial for OMT, these drugs can also be abused by intravenous administration. In intravenous abuse cases, the adjuvants lactose and sucrose are excreted in urine without hydrolysis to monosaccharides, since there are no disaccharidases in the blood. We validated enzymatic methods for the analysis of lactose and sucrose in urine. The analytical performance of both assays was considered appropriate for detecting intravenous drug abuse. The principle was proven by analyzing 93 postmortem (PM) urine samples for lactose, following comprehensive toxicological drug screening. In addition, 32 clinical urine samples from potential drug abusers were analyzed to assess the effect of PM changes on the assay. The mean level of lactose was low in clinical samples and relatively low in PM samples in which no drugs were found. Markedly elevated levels were seen in many of the buprenorphine positive samples, suggesting intravenous administration. Enzymatic methods could provide a simple and cost effective way to assess the intravenous administration of OMT drugs or drugs of abuse. Very high levels of glucose in urine may interfere with the assays. Furthermore, other causes for elevated urine disaccharides, such as hypolactasia and increased intestinal permeability, need to be considered in the interpretation of the results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Novel high dose rate lip brachytherapy technique to improve dose homogeneity and reduce toxicity by customized mold

    International Nuclear Information System (INIS)

    Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay

    2014-01-01

    The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a “sandwich” technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the “sandwich” technique to “classic” – interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue “hot spots” and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36–81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1–47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality

  8. Evaluation of medetomidine, ketamine and buprenorphine for neutering feral cats.

    Science.gov (United States)

    Harrison, Kelly A; Robertson, Sheilah A; Levy, Julie K; Isaza, Natalie M

    2011-12-01

    A combination of medetomidine (M, 100 μg/kg), ketamine (K, 10 mg/kg) and buprenorphine (B, 10 μg/kg), administered by intramuscular injection, was evaluated for spaying and castration (neutering) of feral cats (n = 101). Eleven animals (11%) required supplemental anesthesia (isoflurane by mask) to maintain an adequate plane of surgical anesthesia. Atipamezole (A, 125 μg/kg) was administered subcutaneously at the completion of surgery. All cats recovered from surgery and were released the following day. A hemoglobin saturation (SpO(2)) value of cats. This MKB combination can be used in a feral cat sterilization clinic, but isoflurane supplementation may be necessary. Further research is indicated to determine the clinical significance of the low SpO(2) values associated with this anesthetic regimen. Copyright © 2011 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.

  9. Comparative study of SOI/Si hybrid substrates fabricated using high-dose and low-dose oxygen implantation

    International Nuclear Information System (INIS)

    Dong Yemin; Chen Meng; Chen Jing; Wang Xiang; Wang Xi

    2004-01-01

    Hybrid substrates comprising both silicon-on-insulator (SOI) and bulk Si regions have been fabricated using the technique of patterned separation by implantation of oxygen (SIMOX) with high-dose (1.5 x 10 18 cm -2 ) and low-dose ((1.5-3.5) x 10 17 cm -2 ) oxygen ions, respectively. Cross-sectional transmission electron microscopy (XTEM) was employed to examine the microstructures of the resulting materials. Experimental results indicate that the SOI/Si hybrid substrate fabricated using high-dose SIMOX is of inferior quality with very large surface height step and heavily damaged transitions between the SOI and bulk regions. However, the quality of the SOI/Si hybrid substrate is enhanced dramatically by reducing the implant dose. The defect density in transitions is reduced considerably. Moreover, the expected surface height difference does not exist and the surface is exceptionally flat. The possible mechanisms responsible for the improvements in quality are discussed

  10. Dose-dependent high-resolution electron ptychography

    International Nuclear Information System (INIS)

    D'Alfonso, A. J.; Allen, L. J.; Sawada, H.; Kirkland, A. I.

    2016-01-01

    Recent reports of electron ptychography at atomic resolution have ushered in a new era of coherent diffractive imaging in the context of electron microscopy. We report and discuss electron ptychography under variable electron dose conditions, exploring the prospects of an approach which has considerable potential for imaging where low dose is needed

  11. Mutation process at low or high radiation doses

    International Nuclear Information System (INIS)

    Abrahamson, S.; Wisconsin Univ., Madison

    1976-01-01

    A concise review is given of the status of research on the genetic effects of low-level radiation in general. The term ''low dose'' is defined and current theories on low dose are set out. Problems and their solutions are discussed. (author)

  12. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  13. Comparison of traditional low-dose-rate to optimized and nonoptimized high-dose-rate tandem and ovoid dosimetry

    International Nuclear Information System (INIS)

    Decker, William E.; Erickson, Beth; Albano, Katherine; Gillin, Michael

    2001-01-01

    Purpose: Few dose specification guidelines exist when attempting to perform high-dose-rate (HDR) dosimetry. The purpose of this study was to model low-dose-rate (LDR) dosimetry, using parameters common in HDR dosimetry, to achieve the 'pear-shape' dose distribution achieved with LDR tandem and ovoid applications. Methods and Materials: Radiographs of Fletcher-Suit LDR applicators and Nucletron 'Fletcher-like' HDR applicators were taken with the applicators in an idealized geometry. Traditional Fletcher loadings of 3M Cs-137 sources and the Theratronics Planning System were used for LDR dosimetry. HDR dosimetry was performed using the Nucletron Microselectron HDR UPS V11.22 with an Ir-192 source. Dose optimization points were initially located along a line 2 cm lateral to the tandem, beginning at the tandem tip at 0.5-cm intervals, ending at the sail, and optimized to 100% of the point A dose. A single dose optimization point was also placed laterally from the center of each ovoid equal to the radius of the ovoid (ovoid surface dose). For purposes of comparison, dose was also calculated for points A and B, and a point located 1 cm superior to the tandem tip in the plane of the tandem, (point F). Four- and 6-cm tandem lengths and 2.0-, 2.5-, and 3.0-cm ovoid diameters were used for this study. Based on initial findings, dose optimization schemes were developed to best approximate LDR dosimetry. Finally, radiographs were obtained of HDR applications in two patients. These radiographs were used to compare the optimization schemes with 'nonoptimized' treatment plans. Results: Calculated doses for points A and B were similar for LDR, optimized HDR, and nonoptimized HDR. The optimization scheme that used tapered dose points at the tandem tip and optimized a single ovoid surface point on each ovoid to 170% of point A resulted in a good approximation of LDR dosimetry. Nonoptimized HDR resulted in higher doses at point F, the bladder, and at points lateral to the tandem tip

  14. Dose finding study of granisetron in patients receiving high-dose cisplatin chemotherapy. The Granisetron Study Group.

    Science.gov (United States)

    Riviere, A.

    1994-01-01

    The efficacy and safety of three different doses of granisetron (2 micrograms kg-1, group A; 10 micrograms kg-1, group B; 40 micrograms kg-1, group C) were compared in a randomised, double-blind study of 157 patients due to receive high-dose cisplatin therapy (mean dose > 97 mg m-2). In each group, up to two 3 mg rescue doses of granisetron were allowed if more than mild nausea or vomiting occurred. In group A 30.8%, in group B 61.5% and in group C 67.9% of patients were complete responders (i.e. no vomiting or nothing worse than mild nausea) during the first 24 h. These differences are significant between groups A and B, and A and C. There were no statistically significant differences in any efficacy variable between the 10 micrograms kg-1 and 40 micrograms kg-1 groups, although in each case the trend favoured the higher dose. Additional rescue doses resulted in resolved or improved symptoms in 95.3% for the first rescue dose and 93.3% for the second. Over the 7 days of the study, 82.7%, 82.7% and 86.8% of patients in groups A, B and C respectively were treated with granisetron alone. Headache was the most common side-effect, reported by 9.6% of patients; the majority of headaches were mild. There was no difference between the treatment groups regarding the adverse event rate. We concluded that prophylactic doses of 10 or 40 micrograms kg-1 lead to a safe and satisfactory degree of control of nausea and vomiting induced by high-dose cisplatin. PMID:8180032

  15. A comparison of high-dose and low-dose tranexamic acid antifibrinolytic protocols for primary coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Stephen M McHugh

    2016-01-01

    Full Text Available Background and Aims: Tranexamic acid (TA is used for prophylactic antifibrinolysis in coronary artery bypass surgeries to reduce bleeding. We evaluated the efficacy of two different doses of TA for prophylactic antifibrinolysis in patients undergoing primary coronary artery bypass grafting (CABG surgery in this retrospective cohort study at a tertiary care referral centre. Methods: One-hundred eighty-four patients who underwent primary CABG with cardiopulmonary bypass (CPB via sternotomy between January 2009 and June 2011 were evaluated. Pre-operative patient characteristics, intraoperative data, post-operative bleeding, transfusions, organ dysfunction and 30-day mortality were compared between high-dose TA (30 mg/kg loading dose followed by infusion of 15 mg/kg/h until the end of surgery along with 2 mg/kg priming dose in the bypass circuit and low-dose TA (15 mg/kg loading dose followed by infusion of 6 mg/kg/h until the end of surgery along with 1 mg/kg priming dose in the bypass circuit groups. Univariate comparative analysis of all categorical and continuous variables was performed between the two groups by appropriate statistical tests. Linear and logistic regression analyses were performed to control for the effect of confounding on the outcome variables. Results: Chest tube output, perioperative transfusion of blood products and incidence of re-exploration for bleeding did not differ significantly (P> 0.05 between groups. Post-operative complications and 30-day mortality were comparable between the groups. The presence of cardiogenic shock and increased pre-operative creatinine were found to be associated with increased chest tube output on the post-operative day 2 by multivariable linear regression model. Conclusions: Low-dose TA protocol is as effective as high-dose protocol for antifibrinolysis in patients undergoing primary CABG with CPB.

  16. Split high-dose oral levothyroxine treatment as a successful therapy option in myxedema coma.

    Science.gov (United States)

    Charoensri, Suranut; Sriphrapradang, Chutintorn; Nimitphong, Hataikarn

    2017-10-01

    High-dose intravenous thyroxine (T4) is the preferable treatment for myxedema coma. We describe the clinical course of a 69-year-old man who presented with myxedema coma and received oral levothyroxine (LT4) therapy (1 mg) in a split dose. This suggests split high-dose oral LT4 as a therapeutic option in myxedema coma.

  17. SU-E-T-636: Investigation of Dose Variation in High Dose Radiation Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hyvarinen, M; Leventouri, T; Casey, C; Long, S [Florida Atlantic University, Boca Raton, FL (United States); Pella, S [South Florida Radiation Oncology and Florida Atlantic University, Boca Raton, FL (United States); Dumitru, N [University of Bucharest, Bucharest-magurele, Ilfov (Romania); Herrera, R [Louis Stokes VA Medical Center, Cleveland, OH (United States)

    2014-06-15

    Purpose: The purpose of this study is to revise most of the HDR types of treatments with their applicators and their localization challenges. Since every millimeter of misplacement counts the study will look into the necessity of increasing the immobilization for several types of applicators Methods: The study took over 136 plans generated by the treatment planning system (TPS) looking into the applicator's placement in regard to the organs at risk (OR) and simulated the three possible displacements at the hottest dose point on the critical organ for several accessories to evaluate the variation of the delivered dose at the point due to the displacement. Results: Significant dose variation was obtained for the Contura, Savi, MLM and Prostate applicators. Conclusion: This study data indicates that an improvement of the immobilization devices for HDR is absolutely necessary. Better applicator fixation devices are required too. Developing new immobilization devices for all the applicators is recommended. Florida Atlantic University may provide Travel reimbursements.

  18. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  19. The application of high dose food irradiation in South Africa

    Science.gov (United States)

    de Bruyn, Ingrid Nine

    2000-03-01

    During the 1950s to the end of the 1970s the United States Army developed the basic methodology to produce shelf-stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive "dried cooked" taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The Biogam group at the Atomic Energy Corporation of South Africa is currently producing shelf-stable irradiated meats on a commercial basis. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 45 kGy at a temperature of between -20 and -40°C to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions and can be guaranteed for more than two years as long as the integrity of the packaging is maintained. Safari operators in remote parts of Africa, mountaineers, yachtsmen, canoeists and geological survey teams currently use shelf-stable irradiated meat products produced in South Africa.

  20. The application of high dose food irradiation in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Bruyn, Ingrid Nine de E-mail: debruyni@mweb.co.za

    2000-03-01

    During the 1950s to the end of the 1970s the United States Army developed the basic methodology to produce shelf-stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive 'dried cooked' taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The Biogam group at the Atomic Energy Corporation of South Africa is currently producing shelf-stable irradiated meats on a commercial basis. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 45 kGy at a temperature of between -20 and -40 deg. C to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions and can be guaranteed for more than two years as long as the integrity of the packaging is maintained. Safari operators in remote parts of Africa, mountaineers, yachtsmen, canoeists and geological survey teams currently use shelf-stable irradiated meat products produced in South Africa. (author)

  1. High dose implantations of antimony for buried layer applications

    International Nuclear Information System (INIS)

    Gailliard, J.P.; Dupuy, M.; Garcia, M.; Roussin, J.C.

    1978-01-01

    Electrical and physical properties of high dose implantations of antimony in silicon have been studied for use in buried layer applications. The results have been obtained both on and oriented silicon wafers. Following implantations which lead to amorphization we perform an annealing at 600 0 C for 10 mn in order to recrystallize the layer. The observed electrical properties (μ, R) show that the concentration of electrically active antimony ions is greater than that predicted from the solubility of antimony in silicon. Further annealing (in the range 1050 0 - 1200 0 ) induces: firstly a precipitation of the Sb and secondly a diffusion and dissolution of the precipitates. There is a different evolution of the defects in the and silicon slices. T.E.M. reveals no defects in the wafers after one hour annealing at 1200 0 C, whereas defects and twins remain in wafers. Having obtained the evolution of R with time and temperature it is then determined the implantation and annealing conditions which lead to the low resistivity (R = 10) needed for buried layer applications. Results with very many industrially made devices are discussed

  2. Cation disorder in high-dose, neutron-irradiated spinel

    International Nuclear Information System (INIS)

    Sickafus, K.E.; Larson, A.C.; Yu, N.; Nastasi, M.; Hollenberg, G.W.; Garner, F.A.; Bradt, R.C.

    1994-08-01

    The objective of this effort is to determine whether MgAl 2 O 4 spinel is a suitable ceramic for fusion applications. Here, the crystal structures of MgAl 2 O 4 spinel single crystals irradiated to high neutron fluences [>5·10 26 n/m 2 (E n > 0.1 MeV)] were examined by neutron diffraction. Crystal structure refinement of the highest dose sample indicated that the average scattering strength of the tetrahedral crystal sites decreased by ∼ 20% while increasing by ∼ 8% on octahedral sites. Since the neutron scattering length for Mg is considerably larger than for Al, this results is consistent with site exchange between Mg 2+ ions on tetrahedral sites and Al 3+ ions on octahedral sites. Least-squares refinements also indicated that, in all irradiated samples, at least 35% of Mg 2+ and Al 3+ ions in the crystal experienced disordering replacements. This retained dpa on the cation sublattices is the largest retained damage ever measured in an irradiated spinel material

  3. The application of high dose food irradiation in South Africa

    International Nuclear Information System (INIS)

    Bruyn, Ingrid Nine de

    2000-01-01

    During the 1950s to the end of the 1970s the United States Army developed the basic methodology to produce shelf-stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive 'dried cooked' taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The Biogam group at the Atomic Energy Corporation of South Africa is currently producing shelf-stable irradiated meats on a commercial basis. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 45 kGy at a temperature of between -20 and -40 deg. C to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions and can be guaranteed for more than two years as long as the integrity of the packaging is maintained. Safari operators in remote parts of Africa, mountaineers, yachtsmen, canoeists and geological survey teams currently use shelf-stable irradiated meat products produced in South Africa. (author)

  4. Colon mucosal cells after high-dose fractional irradiation

    International Nuclear Information System (INIS)

    Zorc-Pleskovic, R.; Vraspir-Porenta, O.; Petrovic, D.; Zorc, M.; Pleskovic, L.

    2000-01-01

    The aim of this study was to investigate histological and stereological changes in cryptal enterocytes, mucosal lymphocytes and mast cells 10 days after irradiation. For experimental model, 24 Beagle dogs 1-2 years old were used. Twelve dogs were irradiated 20 days with 32 Gy over the whole pelvis and tail. Another 12 dogs represented a control group. For the detection of apoptosis, the TUNEL technique was used. Histological and stereological analyses were performed using a Wild sampling microscope M 1000. In the irradiated group, volume density (P < 0.01), numerical density (P < 0.05) and average volume of lymphocytes (P < 0.001) were significantly lower than in the nonirradiated group. Numerical areal density of mast cells in the irradiated group was also significantly lower (P < 0.05). Volume density (P < 0.001) and average volume of mast cells (P < 0.001) were significantly higher in the irradiated group. The results of our experiments show that irradiation causes injury and loss of lymphocytes and mast cells in the colon mucosa. Apoptosis was detected in enterocytes and lymphocytes in the irradiated group and in nonirradiated group in equal numbers (2.5 ± 0.3 vs. 2.3 ± 0.3; ns.), suggesting that 10 days after high-dose irradiation, the cell loss is not due to apoptosis. (author)

  5. High dose neutron irradiation damage in beryllium as blanket material

    Energy Technology Data Exchange (ETDEWEB)

    Chakin, V.P. E-mail: fae@niiar.ru; Kazakov, V.A.; Teykovtsev, A.A.; Pimenov, V.V.; Shimansky, G.A.; Ostrovsky, Z.E.; Suslov, D.N.; Latypov, R.N.; Belozerov, S.V.; Kupriyanov, I.B. E-mail: vniinm.400@g23.relkom.ru

    2001-11-01

    The paper presents the investigation results of beryllium products that operated in the SM and BOR-60 reactors up to neutron doses of 2.8x10{sup 22} and 8.0x10{sup 22} cm{sup -2} (E>1 MeV), respectively. The calculated and experimental data are given on helium and tritium accumulation, swelling, micro-hardness and thermal conductivity. The microstructural investigation results of irradiated beryllium are also presented. It is shown that the rate of helium and tritium accumulation in beryllium in the SM and BOR-60 reactors is high enough, which is of interest from the viewpoint of modeling the working conditions of the DEMO fusion reactor. Swelling of beryllium at irradiation temperature of 70-150 deg. C and neutron fluence of 2.8x10{sup 22} cm{sup -2} (E>1 MeV) makes up 0.8-1.5%, at 400 deg. C and fluence of 8x10{sup 22} cm{sup -2} (E>1 MeV)-3.2-5.0%. Irradiation hardening and decrease of thermal conductivity strongly depend on the irradiation temperature and are more significant at reduced temperatures. All results presented in the paper were analyzed with due account of the supposed working parameters of the DEMO fusion reactor blanket.

  6. High dose neutron irradiation damage in beryllium as blanket material

    International Nuclear Information System (INIS)

    Chakin, V.P.; Kazakov, V.A.; Teykovtsev, A.A.; Pimenov, V.V.; Shimansky, G.A.; Ostrovsky, Z.E.; Suslov, D.N.; Latypov, R.N.; Belozerov, S.V.; Kupriyanov, I.B.

    2001-01-01

    The paper presents the investigation results of beryllium products that operated in the SM and BOR-60 reactors up to neutron doses of 2.8x10 22 and 8.0x10 22 cm -2 (E>1 MeV), respectively. The calculated and experimental data are given on helium and tritium accumulation, swelling, micro-hardness and thermal conductivity. The microstructural investigation results of irradiated beryllium are also presented. It is shown that the rate of helium and tritium accumulation in beryllium in the SM and BOR-60 reactors is high enough, which is of interest from the viewpoint of modeling the working conditions of the DEMO fusion reactor. Swelling of beryllium at irradiation temperature of 70-150 deg. C and neutron fluence of 2.8x10 22 cm -2 (E>1 MeV) makes up 0.8-1.5%, at 400 deg. C and fluence of 8x10 22 cm -2 (E>1 MeV)-3.2-5.0%. Irradiation hardening and decrease of thermal conductivity strongly depend on the irradiation temperature and are more significant at reduced temperatures. All results presented in the paper were analyzed with due account of the supposed working parameters of the DEMO fusion reactor blanket

  7. High dose progesterone effects the growth of early chick embryo

    International Nuclear Information System (INIS)

    Iqbal, I.; Qamar, K.

    2014-01-01

    Objective: To find out the effect of high dose progesterone on the development of early chick embryo. Study Design: Lab based randomized controlled trial. Place and Duration of study: This study was carried out in Army Medical College and Post Graduate Institute of Poultry Sciences, Rawalpindi from June 2010 - December 2010. Material and Methods: Forty five specific pathogen free, fertile, eggs of Fyoumi species of chick were selected at zero hour of incubation. They were incubated at 37.5oC and 75% relative humidity for 26 hrs until the embryos reached stage 8 of the development. Then on stage 8 the eggs were divided into three groups consisting of 15 eggs per group. The first group (GI) was incubated without any operation. The second (G2) and third groups (G3) were injected with two and twenty times more than physiologic does of progesterone respectively. After 48 hours of incvbation, all embryos were examined for their development under light microscopy. Results: All the embryos of G1 and G2 showed normal development according to their stage of development, while 4 out of 11 embryos of G3 were under developed and their survival rate was also less. Conclusion: Exogenous progesterone at levels twenty times above its physiologic range effects the development of chick embryos. Further studies are needed to explain the mechanisms of this effect. (author)

  8. Identifying high dose activities in industrial site radiography

    International Nuclear Information System (INIS)

    Heaton, B.

    2000-01-01

    Although the radiation doses received by industrial radiographers in the UK have progressively fallen over the last few years, with most now receiving less than 1 mSv/y, a few still receive, relative to the rest, much higher doses. As a percentage of all radiographers the number stays surprisingly constant from year to year. This paper describes a survey to identify the work causing these doses and suggest possible solutions. The UK Central Index of Dose Information was interrogated to identify the industrial radiography companies having staff (not necessarily the same person) with doses of greater than 5mSv/y in the last three years for which information was available. This was 15 in total. The people on the staff receiving these doses were identified and a questionnaire sent to the companies concerned requesting information about their work. A general questionnaire about the operation of the company was also included. With the agreement of the company these questionnaires were followed up by a visit to the company to interviews a number of the management and the radiographers if available. Both groups were generally very open about their problems and every discussion had a positive outcome. Several areas of work/reasons for the doses have been identified. These are: pipeline radiography, ultra sound radiographers working on nuclear reactors, complex plant work often with several teams in the area, inability to retreat from the wind out equipment due to height or access problems, site pressure to not follow the best practices and a lack of appreciation when a dose was being received or, alternatively, carelessness. Some o these problem areas are very difficult to resolve. However ways in which the Health and Safety can help influence the doses have been identified together with practical suggestions radiographers could adopt. These will be reported. (author)

  9. Study of absorbed dose distribution to high energy electron beams

    International Nuclear Information System (INIS)

    Cecatti, E.R.

    1983-01-01

    The depth absorbed dose distribution by electron beams was studied. The influence of the beam energy, the energy spread, field size and design characteristics of the accelerator was relieved. Three accelerators with different scattering and collimation systems were studied leading todifferent depth dose distributions. A theoretical model was constructed in order to explain the increase in the depth dose in the build-up region with the increase of the energy. The model utilizes a three-dimensional formalism based on the Fermi-Eyges multiple scattering theory, with the introduction of modifications that takes into account the criation of secondary electrons. (Author) [pt

  10. High-dose-rate brachytherapy in uterine cervical carcinoma

    International Nuclear Information System (INIS)

    Patel, Firuza D.; Rai, Bhavana; Mallick, Indranil; Sharma, Suresh C.

    2005-01-01

    Purpose: High-dose-rate (HDR) brachytherapy is in wide use for curative treatment of cervical cancer. The American Brachytherapy Society has recommended that the individual fraction size be <7.5 Gy and the range of fractions should be four to eight; however, many fractionation schedules, varying from institution to institution, are in use. We use 9 Gy/fraction of HDR in two to five fractions in patients with carcinoma of the uterine cervix. We found that our results and toxicity were comparable to those reported in the literature and hereby present our experience with this fractionation schedule. Methods and Materials: A total of 121 patients with Stage I-III carcinoma of the uterine cervix were treated with HDR brachytherapy between 1996 and 2000. The total number of patients analyzed was 113. The median patient age was 53 years, and the histopathologic type was squamous cell carcinoma in 93% of patients. The patients were subdivided into Groups 1 and 2. In Group 1, 18 patients with Stage Ib-IIb disease, tumor size <4 cm, and preserved cervical anatomy underwent simultaneous external beam radiotherapy to the pelvis to a dose of 40 Gy in 20 fractions within 4 weeks with central shielding and HDR brachytherapy of 9 Gy/fraction, given weekly, and interdigitated with external beam radiotherapy. The 95 patients in Group 2, who had Stage IIb-IIIb disease underwent external beam radiotherapy to the pelvis to a dose of 46 Gy in 23 fractions within 4.5 weeks followed by two sessions of HDR intracavitary brachytherapy of 9 Gy each given 1 week apart. The follow-up range was 3-7 years (median, 36.4 months). Late toxicity was graded according to the Radiation Therapy Oncology Group criteria. Results: The 5-year actuarial local control and disease-free survival rate was 74.5% and 62.0%, respectively. The actuarial local control rate at 5 years was 100% for Stage I, 80% for Stage II, and 67.2% for Stage III patients. The 5-year actuarial disease-free survival rate was 88.8% for

  11. Memory function in opioid-dependent patients treated with methadone or buprenorphine along with benzodiazepine: longitudinal change in comparison to healthy individuals

    Directory of Open Access Journals (Sweden)

    Rapeli Pekka

    2009-04-01

    buprenorphine/naloxone group. Conclusion Working memory may be persistently affected in OST patients with BZD use. A high number of memory complaints among OST patients with BZD use may indicate memory consolidation impairment. These findings show that recovery of memory function in OD patients treated along with BZDs takes time, and their memory complaints may have practical relevance.

  12. Efficacy and Safety of Single and Double Doses of Ivermectin versus 7-Day High Dose Albendazole for Chronic Strongyloidiasis

    Science.gov (United States)

    Suputtamongkol, Yupin; Premasathian, Nalinee; Bhumimuang, Kid; Waywa, Duangdao; Nilganuwong, Surasak; Karuphong, Ekkapun; Anekthananon, Thanomsak; Wanachiwanawin, Darawan; Silpasakorn, Saowaluk

    2011-01-01

    , and double doses of oral ivermectin respectively (P = 0.006) in modified intention to treat analysis. No serious adverse event associated with treatment was found in any of the groups. Conclusion/Significance This study confirms that both a single, and a double dose of oral ivermectin taken two weeks apart, is more effective than a 7-day course of high dose albendazole for patients with chronic infection due to S. stercoralis. Double dose of ivermectin, taken two weeks apart, might be more effective than a single dose in patients with concomitant illness. Trial Registration ClinicalTrials.gov NCT00765024 PMID:21572981

  13. Independent verification of the delivered dose in High-Dose Rate (HDR) brachytherapy

    International Nuclear Information System (INIS)

    Portillo, P.; Feld, D.; Kessler, J.

    2009-01-01

    An important aspect of a Quality Assurance program in Clinical Dosimetry is an independent verification of the dosimetric calculation done by the Treatment Planning System for each radiation treatment. The present paper is aimed at creating a spreadsheet for the verification of the dose recorded at a point of an implant with radioactive sources and HDR in gynecological injuries. An 192 Ir source automatic differed loading equipment, GammaMedplus model, Varian Medical System with HDR installed at the Angel H. Roffo Oncology Institute has been used. The planning system implemented for getting the dose distribution is the BraquiVision. The sources coordinates as well as those of the calculation point (Rectum) are entered into the Excel-devised verification program by assuming the existence of a point source in each one of the applicators' positions. Such calculation point has been selected as the rectum is an organ at risk, therefore determining the treatment planning. The dose verification is performed at points standing at a sources distance having at least twice the active length of such sources, so they may be regarded as point sources. Most of the sources used in HDR brachytherapy with 192 Ir have a 5 mm active length for all equipment brands. Consequently, the dose verification distance must be at least of 10 mm. (author)

  14. Retention in buprenorphine treatment is associated with improved HCV care outcomes.

    Science.gov (United States)

    Norton, B L; Beitin, A; Glenn, M; DeLuca, J; Litwin, A H; Cunningham, C O

    2017-04-01

    Persons who inject drugs, most of whom are opioid dependent, comprise the majority of the HCV infected in the United States. As the national opioid epidemic unfolds, increasing numbers of people are entering the medical system to access treatment for opioid use disorder, specifically with buprenorphine. Yet little is known about HCV care in patients accessing buprenorphine-based opioid treatment. We sought to determine the HCV prevalence, cascade of care, and the association between patient characteristics and completion of HCV cascade of care milestones for patients initiating buprenorphine treatment. We reviewed electronic health records of all patients who initiated buprenorphine treatment at a primary-care clinic in the Bronx, NY between January 2009 and January 2014. Of the 390 patients who initiated buprenorphine treatment, 123 were confirmed to have chronic HCV infection. The only patient characteristic associated with achieving HCV care milestones was retention in opioid treatment. Patients retained (vs. not retained) in buprenorphine treatment were more likely to be referred for HCV specialty care (63.1% vs. 34.0%, p<0.01), achieve an HCV-specific evaluation (40.8% vs. 21.3%, p<0.05), be offered HCV treatment (22.4% vs. 8.5%, p<0.05), and initiate HCV treatment (9.2% vs. 6.4%, p=0.6). Given the current opioid epidemic in the US and the growing number of people receiving buprenorphine treatment, there is an unprecedented opportunity to access and treat persons with HCV, reducing HCV transmission, morbidity and mortality. Retention in opioid treatment may improve linkage and retention in HCV care; innovative models of care that integrate opioid drug treatment with HCV treatment are essential. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. High doses dosimetry in irradiation process in Argentine

    International Nuclear Information System (INIS)

    Dorda de Cancio, E.M.

    1997-01-01

    These report describes the lung dose dosimetry procedures of the Semi-Industrial Irradiation Plant in Ezeisa Atomic (500,00 Ci of Co 60) and Industrial Picorrad Plant (400,00 Ci of Co 60) using the nitrate dosimeter

  16. High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Skwarchuk, Mark W.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1997-01-01

    Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters are afterloaded with two 192 Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th 12 -L 2 . Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED 50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED 50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED 50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the

  17. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  18. High versus low-dose rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Patankar, Sonali S; Tergas, Ana I; Deutsch, Israel; Burke, William M; Hou, June Y; Ananth, Cande V; Huang, Yongmei; Neugut, Alfred I; Hershman, Dawn L; Wright, Jason D

    2015-03-01

    Brachytherapy plays an important role in the treatment of cervical cancer. While small trials have shown comparable survival outcomes between high (HDR) and low-dose rate (LDR) brachytherapy, little data is available in the US. We examined the utilization of HDR brachytherapy and analyzed the impact of type of brachytherapy on survival for cervical cancer. Women with stages IB2-IVA cervical cancer treated with primary (external beam and brachytherapy) radiotherapy between 2003-2011 and recorded in the National Cancer Database (NCDB) were analyzed. Generalized linear mixed models and Cox proportional hazards regression were used to examine predictors of HDR brachytherapy use and the association between HDR use and survival. A total of 10,564 women including 2681 (25.4%) who received LDR and 7883 (74.6%) that received HDR were identified. Use of HDR increased from 50.2% in 2003 to 83.9% in 2011 (Puse of HDR. While patients in the Northeast were more likely to receive HDR therapy, there were no other clinical or socioeconomic characteristics associated with receipt of HDR. In a multivariable Cox model, survival was similar between the HDR and LDR groups (HR=0.93; 95% CI 0.83-1.03). Similar findings were noted in analyses stratified by stage and histology. Kaplan-Meier analyses demonstrated no difference in survival based on type of brachytherapy for stage IIB (P=0.68), IIIB (P=0.17), or IVA (P=0.16) tumors. The use of HDR therapy has increased rapidly. Overall survival is similar for LDR and HDR brachytherapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Escalation to High Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease

    Science.gov (United States)

    Triplett, Brandon M.; Kuttab, Hani I.; Kang, Guolian; Leung, Wing

    2015-01-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those utilized in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial, 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. There was no observed increase in toxicity until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10–100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, while those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (p=0.008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose escalation strategy remains unclear, as outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. PMID:26278046

  20. Escalation to High-Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease.

    Science.gov (United States)

    Triplett, Brandon M; Kuttab, Hani I; Kang, Guolian; Leung, Wing

    2015-12-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those used in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. Increased toxicity was not observed until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10 and 100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, whereas those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (P = .008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose-escalation strategy remains unclear, because outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. Copyright © 2015 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  1. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    Science.gov (United States)

    Jaccard, Maud; Petersson, Kristoffer; Buchillier, Thierry; Germond, Jean-François; Durán, Maria Teresa; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François O; Bailat, Claude

    2017-02-01

    The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋ m ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋ p ) of up to 8 × 10 6 Gy/s. To do this, we evaluated the overall uncertainties in EBT3 film dosimetry as well as the energy and dose-rate dependence of their response. Our dosimetric system was composed of EBT3 Gafchromic films in combination with a flatbed scanner and was calibrated against an ionization chamber traceable to primary standard. All sources of uncertainties in EBT3 dosimetry were carefully analyzed using irradiations at a clinical radiotherapy linac. Energy dependence was investigated with the same machine by acquiring and comparing calibration curves for three different beam energies (4, 8 and 12 MeV), for doses between 0.25 and 30 Gy. Ḋ m dependence was studied at the clinical linac by changing the pulse repetition frequency (f) of the beam in order to vary Ḋ m between 0.55 and 4.40 Gy/min, while Ḋ p dependence was probed at the prototype machine for Ḋ p ranging from 7 × 10 3 to 8 × 10 6 Gy/s. Ḋ p dependence was first determined by studying the correlation between the dose measured by films and the charge of electrons measured at the exit of the machine by an induction torus. Furthermore, we compared doses from the films to independently calibrated thermo-luminescent dosimeters (TLD) that have been reported as being dose-rate independent up to such high dose-rates. We report that uncertainty below 4% (k = 2) can be achieved in the dose range between 3 and 17 Gy. Results also demonstrated that EBT3 films did not display any detectable energy dependence for electron beam energies between 4 and 12 MeV. No Ḋ m dependence was found either. In addition, we obtained excellent consistency between films and TLDs over the entire Ḋ p

  2. Biological impact of high-dose and dose-rate radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Maliev, V.; Popov, D. [Russian Academy of Science, Vladicaucas (Russian Federation); Jones, J.; Gonda, S. [NASA -Johnson Space Center, Houston (United States); Prasad, K.; Viliam, C.; Haase, G. [Antioxida nt Research Institute, Premier Micronutrient Corporation, Novato (United States); Kirchin, V. [Moscow State Veterinary and Biotechnology Acade my, Moscow (Russian Federation); Rachael, C. [University Space Research Association, Colorado (United States)

    2006-07-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  3. Biological impact of high-dose and dose-rate radiation exposure

    International Nuclear Information System (INIS)

    Maliev, V.; Popov, D.; Jones, J.; Gonda, S.; Prasad, K.; Viliam, C.; Haase, G.; Kirchin, V.; Rachael, C.

    2006-01-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  4. Cancer radiotherapy based on femtosecond IR laser-beam filamentation yielding ultra-high dose rates and zero entrance dose.

    Science.gov (United States)

    Meesat, Ridthee; Belmouaddine, Hakim; Allard, Jean-François; Tanguay-Renaud, Catherine; Lemay, Rosalie; Brastaviceanu, Tiberius; Tremblay, Luc; Paquette, Benoit; Wagner, J Richard; Jay-Gerin, Jean-Paul; Lepage, Martin; Huels, Michael A; Houde, Daniel

    2012-09-18

    Since the invention of cancer radiotherapy, its primary goal has been to maximize lethal radiation doses to the tumor volume while keeping the dose to surrounding healthy tissues at zero. Sadly, conventional radiation sources (γ or X rays, electrons) used for decades, including multiple or modulated beams, inevitably deposit the majority of their dose in front or behind the tumor, thus damaging healthy tissue and causing secondary cancers years after treatment. Even the most recent pioneering advances in costly proton or carbon ion therapies can not completely avoid dose buildup in front of the tumor volume. Here we show that this ultimate goal of radiotherapy is yet within our reach: Using intense ultra-short infrared laser pulses we can now deposit a very large energy dose at unprecedented microscopic dose rates (up to 10(11) Gy/s) deep inside an adjustable, well-controlled macroscopic volume, without any dose deposit in front or behind the target volume. Our infrared laser pulses produce high density avalanches of low energy electrons via laser filamentation, a phenomenon that results in a spatial energy density and temporal dose rate that both exceed by orders of magnitude any values previously reported even for the most intense clinical radiotherapy systems. Moreover, we show that (i) the type of final damage and its mechanisms in aqueous media, at the molecular and biomolecular level, is comparable to that of conventional ionizing radiation, and (ii) at the tumor tissue level in an animal cancer model, the laser irradiation method shows clear therapeutic benefits.

  5. Share of erythema dose of solar radiation in high mountains

    International Nuclear Information System (INIS)

    Blumthaler, M.; Ambach, W.

    1987-01-01

    The erythema dose was measured using a Robertson-Berger Sunburn Meter. The spectral sensitivity of the detector is adapted to an erythema action spectrum with the optical center at about 300 nm. The erythema dose is expressed in the biologically relevant Sunburn Units (SU). The Robertson-Berger Sunburn Meter has been recommended by the WMO for global monitoring of solar UV-B erythema dose. UV-A radiation was measured with a UV-radiometer. The spectral sensitivity of the detector has a flat maximum at 345 nm and a half band width of +- 25 nm. Global radiation was measured using a pyranometer. All detectors were placed horizontally and calibrated several times. Readings were taken in intervals of one minute

  6. Antinociceptive efficacy of buprenorphine and hydromorphone in red-eared slider turtles (Trachemys scripta elegans).

    Science.gov (United States)

    Mans, Christoph; Lahner, Lesanna L; Baker, Bridget B; Johnson, Stephen M; Sladky, Kurt K

    2012-09-01

    Despite the frequent clinical use of buprenorphine in reptiles, its antinociceptive efficacy is not known. In a randomized, complete cross-over study, the antinociceptive efficacy of buprenorphine (0.2 mg/kg s.c.) was compared with hydromorphone (0.5 mg/kg s.c.), and saline (0.9% s.c. equivalent volume) in 11 healthy red-eared slider turtles (Trachemys scripta elegans). Additionally, buprenorphine at 0.1 and 1 mg/kg was compared with saline in six turtles. Hindlimb withdrawal latencies were measured after exposure to a focal, thermal noxious stimulus before and between 3 hr and up to 96 hr after drug administration. Buprenorphine did not significantly increase hindlimb withdrawal latencies at any time point compared with saline. In contrast, hydromorphone administration at 0.5 mg/kg significantly increased hindlimb withdrawal latencies for up to 24 hr. These results show that hydromorphone, but not buprenorphine, provides thermal antinociception in red-eared slider turtles.

  7. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  8. Analysis of final products from the liquid alkanes radiolysis at low dose, low temperature and high dose rate

    International Nuclear Information System (INIS)

    Tilquin, B.; Doncker, J. de.

    1991-01-01

    Yields of final products (dimers) from the radiolysis of n-hexane and 2,3-dimethylbutane are studied by capillary chromatographic techniques for trace analysis. Reaction of intermediates with the products, the alkane molecules or impurities, is reduced by using low dose (1 kGy), low temperature (195 K) and high dose rate (LINAC). Temperature is the most important experiment variable; by reducing the temperature, reactions with significant activation energies do not compete with radical-radical termination reactions. Products from LINAC radiolysis provide information about active species (reactive fragment, allylic radical...) which deserve a more detailed examination by direct methods [fr

  9. Dose accumulation of multiple high dose rate prostate brachytherapy treatments in two commercially available image registration systems.

    Science.gov (United States)

    Poder, Joel; Yuen, Johnson; Howie, Andrew; Bece, Andrej; Bucci, Joseph

    2017-11-01

    The purpose of this study was to assess whether deformable image registration (DIR) is required for dose accumulation of multiple high dose rate prostate brachytherapy (HDRPBT) plans treated with the same catheter pattern on two different CT datasets. DIR was applied to 20 HDRPBT patients' planning CT images who received two treatment fractions on sequential days, on two different CT datasets, with the same implant. Quality of DIR in Velocity and MIM image registration systems was assessed by calculating the Dice Similarity Coefficient (DSC) and mean distance to agreement (MDA) for the prostate, urethra and rectum contours. Accumulated doses from each system were then calculated using the same DIR technique and dose volume histogram (DVH) parameters compared to manual addition with no DIR. The average DSC was found to be 0.83 (Velocity) and 0.84 (MIM), 0.80 (Velocity) and 0.80 (MIM), 0.80 (Velocity) and 0.81 (MIM), for the prostate, rectum and urethra contours, respectively. The average difference in calculated DVH parameters between the two systems using dose accumulation was less than 1%, and there was no statistically significant difference found between deformably accumulated doses in the two systems versus manual DVH addition with no DIR. Contour propagation using DIR in velocity and MIM was shown to be at least equivalent to inter-observer contouring variability on CT. The results also indicate that dose accumulation through manual addition of DVH parameters may be sufficient for HDRPBT treatments treated with the same catheter pattern on two different CT datasets. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  10. Development of a program for calculation of second dose and securities in brachytherapy high dose rate

    International Nuclear Information System (INIS)

    Esteve Sanchez, S.; Martinez Albaladejo, M.; Garcia Fuentes, J. D.; Bejar Navarro, M. J.; Capuz Suarez, B.; Moris de Pablos, R.; Colmenares Fernandez, R.

    2015-01-01

    We assessed the reliability of the program with 80 patients in the usual points of prescription of each pathology. The average error of the calculation points is less than 0.3% in 95% of cases, finding the major differences in the axes of the applicators (maximum error -0.798%). The program has proved effective previously testing him with erroneous dosimetry. Thanks to the implementation of this program is achieved by the calculation of the dose and part of the process of quality assurance program in a few minutes, highlighting the case of HDR prostate due to having a limited time. Having separate data sheet allows each institution to its protocols modify parameters. (Author)

  11. Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy

    International Nuclear Information System (INIS)

    Marriott, C. J.; Webber, C. E.; Gulenchyn, K. Y.

    2007-01-01

    On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of 131 I. Radiation doses for the designated caregivers were monitored on an hourly basis for 1 week using electronic personal dosemeters. The average penetrating dose was 98±64 μSv. The maximum penetrating dose was 283 μSv. Measured dose rate profiles showed that, on average, one-third of the caregiver dose was received during the journey home from hospital. The mean dose rate profile showed rapid clearance of 131 I with three distinct phases. The corresponding clearance half-times were 131 I contaminating the home. (authors)

  12. The development of radiocaries after high-dose irradiation

    International Nuclear Information System (INIS)

    Willich, N.; Gundacker, K.; Rohloff, R.

    1988-01-01

    39 patients, who were irradiated with doses of 50 to 70 Gy for ENT-tumors over a period of 3.5 months to three years prior to the examination, showed a rapidly progressing caries of the teeth inside the target volume. The teeth outside the target volume developed a caries of less extent. Radiation induced xerostomia, effects of the irradiation of the soft tissues, nutrition habits and hygienics are discussed as causes for the damage of the teeth. (orig.) [de

  13. Root causes, clinical effects, and outcomes of unintentional exposures to buprenorphine by young children.

    Science.gov (United States)

    Lavonas, Eric J; Banner, William; Bradt, Pamela; Bucher-Bartelson, Becki; Brown, Kimberly R; Rajan, Pradeep; Murrelle, Lenn; Dart, Richard C; Green, Jody L

    2013-11-01

    To characterize the rates, root causes, and clinical effects of unintentional exposures to buprenorphine sublingual formulations among young children and to determine whether exposure characteristics differ between formulations. Unintentional exposures to buprenorphine-containing products among children 28 days to less than 6 years old were collected from the Researched Abuse, Diversion, and Addiction-Related Surveillance System Poison Center Program and Reckitt Benckiser Pharmaceuticals' pharmacovigilance system from October 2009-March 2012. After adjustment for drug availability, negative binomial regression was used to estimate average exposure rates. Root cause assessment was conducted, and an expert clinician panel adjudicated causality and severity of moderate to severe adverse events (AEs). A total of 2380 cases were reviewed, including 4 deaths. Exposures to buprenorphine-naloxone combination film were significantly less frequent than exposures to buprenorphine tablets (rate ratio 3.5 [95% CI, 2.7-4.5]) and buprenorphine-naloxone combination tablets (rate ratio 8.8 [7.2-10.6]). The most commonly identified root causes were medication stored in sight, accessed from a bag or purse, and not stored in the original packaging. Among 536 panel review cases, the most common AEs reported for all formulations were lethargy, respiratory depression, miosis, and vomiting. The highest level AE severity did not differ significantly by formulation. Unintentional exposure to buprenorphine can cause central nervous system depression, respiratory depression, and death in young children. Exposure rates to film formulations are significantly less than to tablet formulations. Package and storage deficiencies contribute to unintentional exposures in young children. Copyright © 2013 Mosby, Inc. All rights reserved.

  14. Desipramine in opioid-dependent cocaine abusers maintained on buprenorphine vs methadone.

    Science.gov (United States)

    Oliveto, A H; Feingold, A; Schottenfeld, R; Jatlow, P; Kosten, T R

    1999-09-01

    Cocaine abuse occurs in 40% to 60% of patients entering opioid maintenance treatment, and effective pharmacotherapies are needed for this combined dependence. This 13-week, randomized, double-blind, placebo-controlled trial evaluated the efficacy of desipramine hydrochloride (0 or 150 mg/d) plus buprenorphine hydrochloride (12 mg/d) or methadone hydrochloride (65 mg/d) in 180 opioid-dependent cocaine abusers (124 men, 56 women). Supervised urine samples were obtained thrice weekly, and self-reported cocaine and heroin use was reported once weekly. Desipramine plasma levels were determined at weeks 4 and 10. In men, opioid abstinence was increased more rapidly over time when treated with methadone than with buprenorphine, whereas cocaine abstinence was increased more with buprenorphine than with methadone. In women, opioid abstinence was increased the least rapidly when treated with buprenorphine plus placebo, while cocaine abstinence was increased more rapidly over time when treated with methadone than with buprenorphine. Regardless of sex or opioid medication, desipramine increased opioid and cocaine abstinence more rapidly over time than placebo. Self-reported opioid use confirmed these findings. Desipramine plasma levels were higher in women than in men, particularly those on buprenorphine maintenance. Higher desipramine plasma levels were associated with greater opioid, but not cocaine, abstinence. Desipramine may be a useful adjunctive medication in facilitating opioid and cocaine abstinence in opioid-maintained patients. The efficacy of opioid medications to treat opioid or cocaine dependence may differ by sex. These findings highlight the importance of including sex as a factor when examining treatment outcome in these types of trials.

  15. High dose rate 192Ir calibration: Indonesia experiences

    International Nuclear Information System (INIS)

    Nasukha; Tjiptanto, D.; Darmasyah, R.; Kurniawan, B.

    2002-01-01

    Indonesia with a population of more than 200 Million people which spread on about 5000 islands, up to now only has 23 radiotherapy centers and some not active anymore. As mention by Parkin et al that Cervix/Utery and breast cancer are the most estimated numbers of new cases of cancers in women for developing countries, stomach and lung cancers in men. Indonesia as a developing country is likely similar to other developing countries on numbers of new cases of cancers in women. But quite different in men, in Indonesia the most common cancers are nasopharynx and thyroid cancers. The use of lr-192 sources in high dose-rate (HDR) remotely afterloaded brachytherapy treatments have greatly increased in recent years and variety of such sources are commercially available. Nine radiotherapy centers in Indonesia installed Nucletron microSelectron HDR remote afterloader. Based on the data of CiptoMangunkusurno Hospital, Jakarta that the most common cancers are the cervix, breast, nasopharynx and thyroid cancers which of percentage are about 31%, 25 %, 13%, and 6 % respectively. It means that the use of HDR 192 Ir brachytherapy has to be an effective tool in the treatments. Two methods have been studied and applied to calibrate HDR 192 Ir brachytherapy in Indonesia, especially for Nucletron microSelectron HDR 192 lr remote afterloader brachytherapy. Calibration of HDR 192 Ir brachytherapy source has been done by Cavity lonization Chamber and with Well Type lonization Chamber. First, 0.6 cc of NE Farmer type dosimeter that was calibrated to 60 Co and 250 kV of x-rays in air kerma was used in this experiment. Position of measurement (detector and source) at the center of the room and about 1 meter from the floor. Eight variation of distances from 10 cm to 40 cms have been carried out measurement as recommended by IAEA-TECDOC-1079. Correction have been given for scatters, non-uniformity, and attenuation. To solve the problem of scatter correction factor was used Matlab programming

  16. Dramatic response to high-dose icotinib in a lung adenocarcinoma patient after erlotinib failure.

    Science.gov (United States)

    Guan, Yin; Zhao, Hong; Meng, Jing; Yan, Xiang; Jiao, ShunChang

    2014-02-01

    Epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) retreatment is rarely administered for non-small cell lung cancer (NSCLC) patients who did not respond to previous TKI treatment. A high dose of TKI may overcome resistance to the standard dose of TKI and have different effectiveness toward cancer compared with the standard dose of TKI. This manuscript describes a dramatic and durable response to high-dose icotinib in a NSCLC patient who did not respond to a previous standard dose of erlotinib. The treatment extended the life of the patient for one additional year. A higher dose of icotinib deserves further study not only for patients whose therapy failed with the standard dose of TKI but also for newly diagnosed NSCLC patients with a sensitive mutation. Serial mutation testing during disease development is necessary for analysis and evaluation of EGFR TKI treatment. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  18. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  19. The Role of High Dose Interleukin-2 in the Era of Targeted Therapy.

    Science.gov (United States)

    Gills, Jessie; Parker, William P; Pate, Scott; Niu, Sida; Van Veldhuizen, Peter; Mirza, Moben; Holzbeierlein, Jeffery M; Lee, Eugene K

    2017-09-01

    We assessed survival outcomes following high dose interleukin-2 in a contemporary cohort of patients during the era of targeted agents. We retrospectively reviewed the records of patients with metastatic renal cell carcinoma treated with high dose interleukin-2 between July 2007 and September 2014. Clinicopathological data were abstracted and patient response to therapy was based on RECIST (Response Evaluation Criteria In Solid Tumors), version 1.1 criteria. The Kaplan-Meier method was used to estimate progression-free and overall survival in the entire cohort, the response to high dose interleukin-2 in regard to previous targeted agent therapy and the response to the targeted agent in relation to the response to high dose interleukin-2. We identified 92 patients, of whom 87 had documentation of a response to high dose interleukin-2. Median overall survival was 34.4 months from the initiation of high dose interleukin-2 therapy in the entire cohort. Patients who received targeted therapy before high dose interleukin-2 had overall survival (median 34.4 and 30.0 months, p = 0.88) and progression-free survival (median 1.5 and 1.7 months, p = 0.8) similar to those in patients who received no prior therapy, respectively. Additionally, patients with a complete or partial response to high dose interleukin-2 had similar outcomes for subsequent targeted agents compared to patients whose best response was stable or progressive disease (median overall survival 30.1 vs 25.4 months, p = 0.4). Our data demonstrate that patient responses to high dose interleukin-2 and to targeted agents before and after receiving high dose interleukin-2 are independent. As such, carefully selected patients should be offered high dose interleukin-2 for the possibility of a complete and durable response without the fear of limiting the treatment benefit of targeted agents. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Moderate- vs high-dose methadone in the treatment of opioid dependence: a randomized trial.

    Science.gov (United States)

    Strain, E C; Bigelow, G E; Liebson, I A; Stitzer, M L

    1999-03-17

    Methadone hydrochloride treatment is the most common pharmacological intervention for opioid dependence, and recent interest has focused on expanding methadone treatment availability beyond traditional specially licensed clinics. However, despite recommendations regarding effective dosing of methadone, controlled clinical trials of higher-dose methadone have not been conducted. To compare the relative clinical efficacy of moderate- vs high-dose methadone in the treatment of opioid dependence. A 40-week randomized, double-blind clinical trial starting in June 1992 and ending in October 1995. Outpatient substance abuse treatment research clinic at the Johns Hopkins University Bayview Campus, Baltimore, Md. One hundred ninety-two eligible clinic patients. Daily oral methadone hydrochloride in the dose range of 40 to 50 mg (n = 97) or 80 to 100 mg (n = 95), with concurrent substance abuse counseling. Opioid-positive urinalysis results and retention in treatment. By intent-to-treat analysis through week 30 patients in the high-dose group had significantly lower rates of opioid-positive urine samples compared with patients in the moderate-dose group (53.0% [95% confidence interval [CI], 46.9%-59.2%] vs 61.9% [95% CI, 55.9%-68.0%]; P = .047. These differences persisted during withdrawal from methadone. Through day 210 no significant difference was evident between dose groups in treatment retention (high-dose group mean retention, 159 days; moderate-dose group mean retention, 157 days). Nineteen (33%) of 57 patients in the high-dose group and 11 (20%) of 54 patients in the moderate-dose group completed detoxification. Both moderate- and high-dose methadone treatment resulted in decreased illicit opioid use during methadone maintenance and detoxification. The high-dose group had significantly greater decreases in illicit opioid use.

  1. Morphine- and buprenorphine-induced analgesia and antihyperalgesia in a human inflammatory pain model

    DEFF Research Database (Denmark)

    Ravn, Pernille; Secher, EL; Skram, U

    2013-01-01

    Opioid therapy is associated with the development of tolerance and paradoxically increased sensitivity to pain. It has been suggested that buprenorphine is associated with a higher antihyperalgesia/analgesia ratio than μ-opioid receptor agonists. The primary outcome of this study was therefore...... to investigate relative differences in antihyperalgesia and analgesia effects between morphine and buprenorphine in an inflammatory pain model in volunteers. The secondary outcome was to examine the relationship between pain sensitivity and opioid-induced effects on analgesia, antihyperalgesia, and descending...... pain modulation....

  2. Buprenorphine, methadone, and morphine treatment during pregnancy: behavioral effects on the offspring in rats

    Directory of Open Access Journals (Sweden)

    Chen HH

    2015-03-01

    Full Text Available Hwei-Hsien Chen,1,2,* Yao-Chang Chiang,3,4,* Zung Fan Yuan,5,6 Chung-Chih Kuo,5,6 Mei-Dan Lai,2 Tsai-Wei Hung,1 Ing-kang Ho,1,3,4 Shao-Tsu Chen2,7 1Center for Neuropsychiatric Research, National Health Research Institutes, Miaoli County, Taiwan; 2Master and PhD Program in Pharmacology and Toxicology, Tzu Chi University, Hualien, Taiwan; 3Center for Drug Abuse and Addiction, China Medical University Hospital, 4Graduate Institute of Clinical Medical Science, China Medical University, Taichung, Taiwan; 5Master Program in Physiological and Anatomical Medicine, 6Department of Physiology, School of Medicine, Tzu Chi University, 7Department of Psychiatry, Buddhist Tzu Chi General Hospital, Hualien, Taiwan *These authors contributed equally to this work Abstract: Methadone and buprenorphine are widely used for treating people with opioid dependence, including pregnant women. Prenatal exposure to opioids has devastating effects on the development of human fetuses and may induce long-term physical and neurobehavioral changes during postnatal maturation. This study aimed at comparing the behavioral outcomes of young rats prenatally exposed to buprenorphine, methadone, and morphine. Pregnant Sprague-Dawley rats were administered saline, morphine, methadone, and buprenorphine during embryonic days 3–20. The cognitive function, social interaction, anxiety-like behaviors, and locomotor activity of offsprings were examined by novel object recognition test, social interaction test, light–dark transition test, elevated plus-maze, and open-field test between 6 weeks and 10 weeks of age. Prenatal exposure to methadone and buprenorphine did not affect locomotor activity, but significantly impaired novel object recognition and social interaction in both male and female offsprings in the same manner as morphine. Although prenatal exposure to methadone or buprenorphine increased anxiety-like behaviors in the light–dark transition in both male and female

  3. Predictors of attrition with buprenorphine/naloxone treatment in opioid dependent youth☆

    Science.gov (United States)

    Warden, Diane; Subramaniam, Geetha A.; Carmody, Thomas; Woody, George E.; Minhajuddin, Abu; Poole, Sabrina A.; Potter, Jennifer; Fishman, Marc; Bogenschutz, Michael; Patkar, Ashwin; Trivedi, Madhukar H.

    2012-01-01

    Background In opioid dependent youth there is substantial attrition from medication-assisted treatment. If youth at risk for attrition can be identified at treatment entry or early in treatment, they can be targeted for interventions to help retain them in treatment. Methods Opioid dependent adolescents and young adults (n=152), aged 15–21, were randomized to 12 weeks (BUP, n=74) or 2 weeks of detoxification (DETOX, n=78) with buprenorphine/naloxone (Bup/Nal), both in combination with 12 weeks of psychosocial treatment. Baseline and early treatment related predictors of treatment attrition were identified in each group using bivariate and multivariate logistic regression. Results In the DETOX group 36% left between weeks 2 and 4, at the end of the dose taper, while in the BUP group only 8% left by week 4. In the BUP group, early adherence to Bup/Nal, early opioid negative urines, use of any medications in the month prior to treatment entry, and lifetime non-heroin opioid use were associated with retention while prior 30-day hallucinogen use was associated with attrition. In the DETOX group, only use of sleep medications was associated with retention although not an independent predictor. A broad range of other pre-treatment characteristics was unrelated to attrition. Conclusions Prompt attention to those with early non-adherence to medication or an early opioid positive urine, markers available in the first 2 weeks of treatment, may improve treatment retention. Extended Bup/ Nal treatment appeared effective in improving treatment retention for youth with opioid dependence across a wide range of demographics, and pre-treatment clinical characteristics. PMID:22626890

  4. Predictors of attrition with buprenorphine/naloxone treatment in opioid dependent youth.

    Science.gov (United States)

    Warden, Diane; Subramaniam, Geetha A; Carmody, Thomas; Woody, George E; Minhajuddin, Abu; Poole, Sabrina A; Potter, Jennifer; Fishman, Marc; Bogenschutz, Michael; Patkar, Ashwin; Trivedi, Madhukar H

    2012-09-01

    In opioid dependent youth there is substantial attrition from medication-assisted treatment. If youth at risk for attrition can be identified at treatment entry or early in treatment, they can be targeted for interventions to help retain them in treatment. Opioid dependent adolescents and young adults (n=152), aged 15-21, were randomized to 12 weeks (BUP, n=74) or 2 weeks of detoxification (DETOX, n=78) with buprenorphine/naloxone (Bup/Nal), both in combination with 12 weeks of psychosocial treatment. Baseline and early treatment related predictors of treatment attrition were identified in each group using bivariate and multivariate logistic regression. In the DETOX group 36% left between weeks 2 and 4, at the end of the dose taper, while in the BUP group only 8% left by week 4. In the BUP group, early adherence to Bup/Nal, early opioid negative urines, use of any medications in the month prior to treatment entry, and lifetime non-heroin opioid use were associated with retention while prior 30-day hallucinogen use was associated with attrition. In the DETOX group, only use of sleep medications was associated with retention although not an independent predictor. A broad range of other pre-treatment characteristics was unrelated to attrition. Prompt attention to those with early non-adherence to medication or an early opioid positive urine, markers available in the first 2 weeks of treatment, may improve treatment retention. Extended Bup/Nal treatment appeared effective in improving treatment retention for youth with opioid dependence across a wide range of demographics, and pre-treatment clinical characteristics. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Genotoxic effects of high dose rate X-ray and low dose rate gamma radiation in ApcMin/+ mice.

    Science.gov (United States)

    Graupner, Anne; Eide, Dag M; Brede, Dag A; Ellender, Michele; Lindbo Hansen, Elisabeth; Oughton, Deborah H; Bouffler, Simon D; Brunborg, Gunnar; Olsen, Ann Karin

    2017-10-01

    Risk estimates for radiation-induced cancer in humans are based on epidemiological data largely drawn from the Japanese atomic bomb survivor studies, which received an acute high dose rate (HDR) ionising radiation. Limited knowledge exists about the effects of chronic low dose rate (LDR) exposure, particularly with respect to the application of the dose and dose rate effectiveness factor. As part of a study to investigate the development of colon cancer following chronic LDR vs. acute HDR radiation, this study presents the results of genotoxic effects in blood of exposed mice. CBAB6 F1 Apc +/+ (wild type) and Apc Min/+ mice were chronically exposed to estimated whole body absorbed doses of 1.7 or 3.2 Gy 60 Co-γ-rays at a LDR (2.2 mGy h -1 ) or acutely exposed to 2.6 Gy HDR X-rays (1.3 Gy min -1 ). Genotoxic endpoints assessed in blood included chromosomal damage (flow cytometry based micronuclei (MN) assay), mutation analyses (Pig-a gene mutation assay), and levels of DNA lesions (Comet assay, single-strand breaks (ssb), alkali labile sites (als), oxidized DNA bases). Ionising radiation (ca. 3 Gy) induced genotoxic effects dependent on the dose rate. Chromosomal aberrations (MN assay) increased 3- and 10-fold after chronic LDR and acute HDR, respectively. Phenotypic mutation frequencies as well as DNA lesions (ssb/als) were modulated after acute HDR but not after chronic LDR. The Apc Min/+ genotype did not influence the outcome in any of the investigated endpoints. The results herein will add to the scant data available on genotoxic effects following chronic LDR of ionising radiation. Environ. Mol. Mutagen. 58:560-569, 2017. © 2017 The Authors Environmental and Molecular Mutagenesis published by Wiley Periodicals, Inc. on behalf of Environmental Mutagen Society. © 2017 The Authors Environmental and Molecular Mutagenesis published by Wiley Periodicals, Inc. on behalf of Environmental Mutagen Society.

  6. INFLUENCE OF HIGH CORTISOL DOSES UPON THE SERUM IMMUNOGLOBULIN LEVEL

    OpenAIRE

    Voja Pavlovic; Zoran Pavlovic

    2001-01-01

    The effects of Cortisol upon the serum immunoglobulin concentration areexamined. The experiment involved male guinea pigs of the body weight from 300 to400 g that were nonnally fed and lived under the common laboratory conditions. Theguinea pigs were divided into an experimental and a control group. The experimentalgroup's guinea pigs were given every day (in a 6 days' period) a subcutaneous dose of80 g of corti sol/kg/per day, while the control group ones were given only one ml ofthe physiol...

  7. Effects of low dose gamma radiation on the early growth of red pepper and the resistance to subsquent high dose of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Baek, M. H.; Kim, D. H.; Lee, Y. K. [KAERI, Taejon (Korea, Republic of); Lee, Y. B. [Chungnam National Univ., Taejon (Korea, Republic of)

    2001-05-01

    Red pepper (capsicum annuum L. cv. Jokwang and cv. Johong) seeds were irradiated with the dose of 0{approx}50 Gy to investigated the effect of the low dose gamma radiation on the early growth and resistance to subsequent high dose of radiation. The effect of the low dose gamma radiation on the early growth and resistance to subsequenct high dose of radiation were enhanced in Johong cultivar but not in Jokwang cultivar. Germination rate and early growth of Johong cultivar were noticeably increased at 4 Gy-, 8 Gy- and 20 Gy irradiation group. Resistance to subsequent high dose of radiation of Johong cultivar were increased at almost all of the low dose irradiation group. Especially it was highest at 4 Gy irradiation group. The carotenoid contents and enzyme activity on the resistance to subsequent high dose of radiation of Johong cultivar were increased at the 4 Gy and 8 Gy irradiation group.

  8. The clinical pharmacology of alkylating agents in high-dose chemotherapy

    NARCIS (Netherlands)

    Huitema, A. D.; Smits, K. D.; Mathôt, R. A.; Schellens, J. H.; Rodenhuis, S.; Beijnen, J. H.

    2000-01-01

    Alkylating agents are widely used in high-dose chemotherapy regimens in combination with hematological support. Knowledge about the pharmacokinetics and pharmacodynamics of these agents administered in high doses is critical for the safe and efficient use of these regimens. The aim of this review is

  9. High daily doses of benzodiazepines among Quebec seniors: prevalence and correlates

    Directory of Open Access Journals (Sweden)

    Moride Yola

    2001-11-01

    Full Text Available Abstract Background Use of high daily doses of benzodiazepines is generally contraindicated for seniors. While both patient and physician factors may influence the use of high daily doses, previous research on the effect of patient factors has been extremely limited. The objectives of this study were to determine the one year prevalence of use of high daily doses of benzodiazepines, and examine physician and patient correlates of such use among Quebec community-dwelling seniors. Methods Patient information for 1423 community-dwelling Quebec seniors who participated in the Canadian Study of Health and Aging was linked to provincial health insurance administrative data bases containing detailed information on prescriptions received and prescribers. Results The standardized one year period prevalence of use of high daily doses of benzodiazepines was 7.9%. Use of high daily doses was more frequent among younger seniors and those who had reported anxiety during the previous year. Patients without cognitive impairment were more likely to receive high dose prescriptions from general practitioners, while those with cognitive impairment were more likely to receive high dose prescriptions from specialists. Conclusion High dose prescribing appears to be related to both patient and physician factors.

  10. Risks Associated with High-Dose Lactobacillus rhamnosus in an Escherichia coli Model of Piglet Diarrhoea

    DEFF Research Database (Denmark)

    Li, Xiao-Qiong; Zhu, Yao-Hong; Zhang, Hong-Fu

    2012-01-01

    might be more effective than a high dose at ameliorating diarrhoea. There is a risk that high-dose L. rhamnosus pretreatment may negate the preventative effects, thus decreasing the prophylactic benefits against potential enteric pathogens. Our data suggest a safe threshold for preventative use...

  11. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  12. Radiotherapy high energy surface dose measurements: effects of chamber polarity

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: The effects of chamber polarity have been investigated for the measurement of 6MV and 18MV x-ray surface dose using a parallel plate ionization chamber. Results have shown that a significant difference in measured ionization is recorded between to polarities at 6MV and 18MV at the phantom surface. A polarity ratio ranging from 1 062 to 1 005 is seen for 6MV x-rays at the phantom surface for field sizes 5cm x 5cm to 40cm x 40cm when comparing positive to negative polarity. These ratios range from 1.024 to 1.004 for 18MV x-rays with the same field sizes. When these charge reading are compared to the D max readings of the same polarity it is found that these polarity effects are minimal for the calculation of percentage dose results with variations being less than 1% of maximum. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  13. Radiation Sialadenitis Induced by High-dose Radioactive Iodine Therapy

    International Nuclear Information System (INIS)

    Jeong, Shin Young; Lee, Jaetae

    2010-01-01

    Radioactive iodine ( 131 I) is accumulated in the thyroid tissue and plays an important role in the treatment of differentiated papillary and follicular cancers after thyroidectomy. Simultaneously, 131 I is concentrated in the salivary glands and secreted into the saliva. Dose-related damage to the salivary parenchyma results from the 131 I irradiation. Salivary gland swelling and pain, usually involving the parotid, can be seen. The symptoms may develop immediately after a therapeutic dose of 131 I and/or months later and progress in intensity with time. In conjunction with the radiation sialadenitis, secondary complications reported include xerostomia, taste alterations, infection, increases in caries, facial nerve involvement, candidiasis, and neoplasia. Prevention of 131 I sialadenitis may involve the use of sialogogic agents to hasten the transit time of the radioactive iodine through the salivary glands. However, studies are not available to delineate the efficacy of this approach. Treatment of the varied complications that may develop encompass numerous approaches and include gland massage, sialogogic agents, duct probing, antibiotics, mouthwashes, good oral hygiene, and adequate hydration. Recently interventional sialoendoscopy has been introduced an effective tool for the management of patients with 131 I-induced sialadenitis that is unresponsive to medical treatment.

  14. Radiation Sialadenitis Induced by High-dose Radioactive Iodine Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Shin Young; Lee, Jaetae [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2010-06-15

    Radioactive iodine ({sup 131}I) is accumulated in the thyroid tissue and plays an important role in the treatment of differentiated papillary and follicular cancers after thyroidectomy. Simultaneously, {sup 131}I is concentrated in the salivary glands and secreted into the saliva. Dose-related damage to the salivary parenchyma results from the {sup 131}I irradiation. Salivary gland swelling and pain, usually involving the parotid, can be seen. The symptoms may develop immediately after a therapeutic dose of {sup 131}I and/or months later and progress in intensity with time. In conjunction with the radiation sialadenitis, secondary complications reported include xerostomia, taste alterations, infection, increases in caries, facial nerve involvement, candidiasis, and neoplasia. Prevention of {sup 131}I sialadenitis may involve the use of sialogogic agents to hasten the transit time of the radioactive iodine through the salivary glands. However, studies are not available to delineate the efficacy of this approach. Treatment of the varied complications that may develop encompass numerous approaches and include gland massage, sialogogic agents, duct probing, antibiotics, mouthwashes, good oral hygiene, and adequate hydration. Recently interventional sialoendoscopy has been introduced an effective tool for the management of patients with {sup 131}I-induced sialadenitis that is unresponsive to medical treatment.

  15. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    International Nuclear Information System (INIS)

    Sandilos, Panagiotis; Baras, Panagiotis; Georgiou, Evangelos; Dardoufas, Konstantinos; Karaiskos, Pantelis; Papagiannis, Panagiotis; Paschalis, Theodoros; Tatsis, Elias; Torrens, Michael; Vlahos, Lampros

    2006-01-01

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an 192 Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications

  16. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    Energy Technology Data Exchange (ETDEWEB)

    Sandilos, Panagiotis [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Baras, Panagiotis [Philips Hellas Medical Systems, 44 Kifissias Ave., Maroussi 151 25, Athens (Greece); Georgiou, Evangelos [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece); Dardoufas, Konstantinos [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Karaiskos, Pantelis [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece)]. E-mail: p.karaiskos@hygeia.gr; Papagiannis, Panagiotis [Physics Department, Nuclear and Particle Physics Section, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Paschalis, Theodoros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Tatsis, Elias [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Torrens, Michael [Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Vlahos, Lampros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece)

    2006-12-20

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an {sup 192}Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications.

  17. A blinded, randomized, controlled trial of three doses of high-dose insulin in poison-induced cardiogenic shock.

    Science.gov (United States)

    Cole, J B; Stellpflug, S J; Ellsworth, H; Anderson, C P; Adams, A B; Engebretsen, K M; Holger, J S

    2013-05-01

    High dose insulin (HDI) has proven superior to glucagon and catecholamines in the treatment of poison-induced cardiogenic shock (PICS) in previous animal studies. Standard recommendations for dosing of insulin vary and the optimal dose of HDI in PICS has not been established. Our hypothesis was a dose of 10 U/kg/hr of HDI would be superior to 1 U/kg/hr with cardiac output (CO) as our primary outcome measure in pigs with propranolol-induced PICS. This was a blinded, prospective, randomized trial with 4 arms consisting of 4 pigs in each arm. The arms were as follows: placebo (P), 1 U/kg/hr (HDI-1), 5 U/kg/hr (HDI-5), and 10 U/kg/hr (HDI-10). Cardiogenic shock was induced with a bolus of 0.5 mg/kg of propranolol followed by an infusion of 0.25 mg/kg/min until the point of toxicity, defined as 0.75 x (HR x MAP) was reached. At this point the propranolol infusion was decreased to 0.125 mg/kg/min and a 20 mL/kg bolus of normal saline (NS) was administered. The protocol was continued for 6 hours or until the animals died. 2 pigs died in the P arm, 1 pig died each in the HDI-1 and HDI-5 arms, and all pigs lived in the HDI-10 arm. There was a statistically significant difference in dose by time interaction on CO of 1.13 L/min over the 6 hr study period (p = < 0.001). There was also a statistically significant difference in dose by time interaction on MAP, HR, and systemic vascular resistance (SVR). No statistically significant difference was found between any of the arms regarding glucose utilization. HDI was statistically and clinically significantly superior to placebo in this propranolol model of PICS. Furthermore a dose response over time was found where CO increased corresponding to increases in doses of HDI.

  18. High dose vitamin D may improve lower urinary tract symptoms in postmenopausal women.

    Science.gov (United States)

    Oberg, Johanna; Verelst, Margareta; Jorde, Rolf; Cashman, Kevin; Grimnes, Guri

    2017-10-01

    Lower urinary tract symptoms (LUTS) are common in postmenopausal women, and have been reported inversely associated with vitamin D intake and serum 25-hydroxyvitamin D (25(OH)D) levels. The aim of this study was to investigate if high dose vitamin D supplementation would affect LUTS in comparison to standard dose. In a randomized controlled study including 297 postmenopausal women with low bone mineral density, the participants were allocated to receive capsules of 20 000IU of vitamin D 3 twice a week (high dose group) or similar looking placebo (standard dose group). In addition, all the participants received 1g of calcium and 800IU of vitamin D daily. A validated questionnaire regarding LUTS was filled in at baseline and after 12 months. At baseline, 76 women in the high dose group and 82 in the standard dose group reported any LUTS. Levels of serum 25(OH)D increased significantly more in the high dose group (from 64.7 to 164.1nmol/l compared to from 64.1 to 81.8nmol/l, p<0.01). No differences between the groups were seen regarding change in LUTS except for a statistically significant reduction in the reported severity of urine incontinence in the high dose group as compared to the standard dose group after one year (p<0.05). The results need confirmation in a study specifically designed for this purpose. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Evaluation of Low- Versus High-dose Valganciclovir for Prevention of Cytomegalovirus Disease in High-risk Renal Transplant Recipients.

    Science.gov (United States)

    Gabardi, Steven; Asipenko, Natalya; Fleming, James; Lor, Kevin; McDevitt-Potter, Lisa; Mohammed, Anisa; Rogers, Christin; Tichy, Eric M; Weng, Renee; Lee, Ruth-Ann

    2015-07-01

    Despite proven efficacy of prolonged cytomegalovirus (CMV) prophylaxis using valganciclovir 900 mg/day, some centers use 450 mg/day due to reported success and cost savings. This multicenter, retrospective study compared the efficacy and safety of 6 months of low-dose versus high-dose valganciclovir prophylaxis in high-risk, donor-positive/recipient-negative, renal transplant recipients (RTR). Two hundred thirty-seven high-risk RTR (low-dose group = valganciclovir 450 mg/day [n = 130]; high-dose group = valganciclovir 900 mg/day [n = s7]) were evaluated for 1-year CMV disease prevalence. Breakthrough CMV, resistant CMV, biopsy-proven acute rejection (BPAR), graft loss, opportunistic infections (OI), new-onset diabetes after transplantation (NODAT), premature valganciclovir discontinuation, renal function and myelosuppression were also assessed. Patient demographics and transplant characteristics were comparable. Induction and maintenance immunosuppression were similar, except for more early steroid withdrawal in the high-dose group. Similar proportions of patients developed CMV disease (14.6% vs 24.3%; P = 0.068); however, controlling CMV risk factor differences through multivariate logistic regression revealed significantly lower CMV disease in the low-dose group (P = 0.02; odds ratio, 0.432, 95% confidence interval, 0.211-0.887). Breakthrough and resistant CMV occurred at similar frequencies. There was no difference in renal function or rates of biopsy-proven acute rejection, graft loss, opportunistic infections, or new-onset diabetes after transplantation. The high-dose group had significantly lower mean white blood cell counts at months 5 and 6; however, premature valganciclovir discontinuation rates were similar. Low-dose and high-dose valganciclovir regimens provide similar efficacy in preventing CMV disease in high-risk RTR, with a reduced incidence of leukopenia associated with the low-dose regimen and no difference in resistant CMV. Low-dose valganciclovir

  20. Problems Concerning Dose Assessments in Epidemiology of High Background Radiation Areas of Yangjiang, China (invited paper)

    International Nuclear Information System (INIS)

    Wei, L.X.; Yuan, Y.L.

    1998-01-01

    The purpose of this study on radiation levels and dose assessments in the epidemiology of a high background radiation area (HBRA) and the control area (CA) is to respond to the needs of epidemiology in these areas, where the inhabitants are continuously exposed to low dose, low dose rate ionising radiation. A brief description is given of how the research group evaluated the feasibility of the investigation by analysing the population size and the radiation levels, how simple reliable methods were used to get the individual annual dose for every cohort member, and how the cohort members were classified into various dose groups for dose-effect relationship analysis. Finally, the use of dose group classification for cancer mortality studies is described. (author)

  1. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Lahanas, M; Baltas, D; Zamboglou, N

    2003-01-01

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives

  2. Comparison of high-dose-rate and low-dose-rate brachytherapy in the treatment of endometrial carcinoma

    International Nuclear Information System (INIS)

    Fayed, Alaa; Mutch, David G.; Rader, Janet S.; Gibb, Randall K.; Powell, Matthew A.; Wright, Jason D.; El Naqa, Issam; Zoberi, Imran; Grigsby, Perry W.

    2007-01-01

    Purpose: To compare the outcomes for endometrial carcinoma patients treated with either high-dose-rate (HDR) or low-dose-rate (LDR) brachytherapy. Methods and Materials: This study included 1,179 patients divided into LDR (1,004) and HDR groups (175). Patients with International Federation of Gynecology and Obstetrics (FIGO) surgical Stages I-III were included. All patients were treated with postoperative irradiation. In the LDR group, the postoperative dose applied to the vaginal cuff was 60-70 Gy surface doses to the vaginal mucosa. The HDR brachytherapy prescription was 6 fractions of 2 Gy each to a depth of 0.5 cm from the surface of the vaginal mucosa. Overall survival, disease-free survival, local control, and complications were endpoints. Results: For all stages combined, the overall survival, disease-free survival, and local control at 5 years in the LDR group were 70%, 69%, and 81%, respectively. For all stages combined, the overall survival, disease-free survival, and local control at 5 years in the HDR group were 68%, 62%, and 78%, respectively. There were no significant differences in early or late Grade III and IV complications in the HDR or LDR groups. Conclusion: Survival outcomes, pelvic tumor control, and Grade III and IV complications were not significantly different in the LDR brachytherapy group compared with the HDR group

  3. High-dose rate fractionated interstitial radiotherapy for oropharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nose, Takayuki; Inoue, Toshihiko; Inoue, Takehiro; Teshima, Teruki; Murayama, Shigeyuki [Osaka Univ. (Japan). Faculty of Medicine

    1995-03-01

    The limitations of treating oropharyngeal cancer patients with definitive external radiotherapy are the complications of salivary glands, taste buds, mandible and temporomandibular joints. To avoid these complications we started interstitial radiotherapy as boost after 46 Gy of external radiotherapy. Ten cases (retromolar trigone; 1, soft palate; 1, base of tongue; 3, lateral wall; 5) were treated with this method and seven cases were controlled locally. With short follow-up period, xerostomia and dysgeusia are less than definitive external radiotherapy as clinical impression and no in-field recurrences have been experienced. With markedly increased tumor dose, the local control rate can be improved. This treatment method will be an alternative to definitive external radiotherapy to gain better QOL and higher control rate. (author).

  4. The high dose and low dose food irradiation programmes in the United States of America

    International Nuclear Information System (INIS)

    Brynjolfsson, A.

    1978-01-01

    Many highly acceptable shelf-stable irradiated food items have been developed in the United States of America. The most extensive wholesomeness studies ever carried out on any food-processing method continue to indicate that irradiated foods are wholesome. (author)

  5. High-dose myeloablative versus conventional low-dose radioimmunotherapy (RIT) of mantle cell lymphoma (MCL) with the chimeric anti-CD20 antibody C2B8

    International Nuclear Information System (INIS)

    Behr, T.M.; Gotthardt, M.; Schipperm, M.L.; Gratz, S.; Behe, M.P.; Brittinger, G.; Woermann, B.; Becker, W.

    2002-01-01

    CD20 has been used as target molecule for low-dose as well as high-dose, myeloablative RIT of B-cell NHL. MCL is an especially aggressive, prognostically unfavorable form of B-cell NHL. The aim of this study was to investigate whether high-dose, myeloablative RIT with the 131 I-labeled chimeric anti-CD20 antibody C2B8 (rituxan, Mabthera, Roche) may be therapeutically more effective than conventional low-dose therapy in MCL. A total of twelve patients with chemorefractory or relapsed mantle cell lymphoma were studied so far (all of them having relapsed after high-dose chemotherapy, seven of them combined with 12 Gy TBI). A diagnostic-dosimetric study was performed with 10 mCi of 131 I-C2B8 at a protein dose of 2.5 mg/kg. In case of splenic pooling, the protein dose was increased until a more 'favorable' biodistribution was obtained. Therapy was performed with conventional (30-75 mCi; n=4) or myeloablative activities (261-515 mCi; n=8) of 131 I-C2B8 at the previously optimized protein dose, aiming at whole-body doses of ≤ 0.8 Gy (for low-dose RIT) or lung doses of ≤ 27 Gy (for high-dose RIT). Clinical follow-up was obtained for up to 42 months. Overall, in 11 patients the 2.5 mg/kg protein dose was used, whereas in one patient with marked splenomegaly, 10 mg/kg were necessary to overcome the splenic antigenic sink. In the high-dose patients, non-hematologic toxicity was restricted to mild to moderate nausea, fever, transient bilirubin or liver enzyme elevations. Despite thyroid blocking, 6/8 high-dose (in contrast to 0/4 low-dose) patients developed hypothyroidism, requiring thyroxine substitution at 6-18 months after RIT. The response rate in the low-dose arm was only 1(PR)/4, whereas 7/8 high-dose patients experienced complete and the remainder a partial remission. 6 high-dose patients are still in CR (one of them relapsed locally at 3 months, one systemically at 26 months after RIT), and 7 are still alive for up to 42+ months. In contrast to low-dose therapy

  6. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer; Avaliacao da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jetro Pereira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina; Rosa, Luiz Antonio Ribeiro da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], e-mail: lrosa@ird.gov.br; Batista, Delano Valdivino Santos; Bardella, Lucia Helena [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil). Unit of Medical Physics; Carvalho, Arnaldo Rangel [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. of Thermoluminescent Dosimetry

    2009-03-15

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  7. High gamma dose response of the electrical properties of polyethylene terephthalate thin films

    International Nuclear Information System (INIS)

    Radwan, R.M.

    2007-01-01

    Electrical properties of polyethylene terephthalate (PET), irradiated with gamma rays, have been investigated. The PET films were irradiated with high gamma dose levels in the range from 100 to 2000 kGy. The changes in the DC (σ DC ) and the ac (σ ac ) conductivities, with the dose, have been performed. The effect of gamma irradiation on the dielectric constant (ε') and loss (ε'') has been determined. Also, the dose dependence of the frequency exponent index (S), the resonance frequency (Fc) and the hopping frequency (ω P ) have been obtained. The obtained results show that increasing gamma dose leads to slight increase in σ DC , σ ac and ε', while no change was observed in ε'' value. Meanwhile, S, Fc and ω P are inversely proportional to the dose. Accordingly, the study suggests the possibility of using PET films in electronic components (capacitors, resistors, etc.), especially that operate at high gamma dose environments for the frequency independent applications

  8. High-dose zolpidem dependence - Psychostimulant effects? A case report and literature review

    Directory of Open Access Journals (Sweden)

    Abhijna Chandan Chattopadhyay

    2016-01-01

    Full Text Available Zolpidem, an imidazoline nonbenzodiazepine sedative drug, is used widely. Initial reports showed minimal abuse potential. However, multiple reports have appeared of dose escalation and abuse. Subjective effects of high-dose zolpidem are not known. In light of accumulating evidence of abuse potential, we hereby report a case of high-dose dependence and a review of relevant literature. A 33-year-old male presented with 5 years of daily use of 600–1700 mg of zolpidem tartrate. He reported subjective effects of euphoria, intense craving, and inability to stop use. Loss of receptor specificity, pharmacokinetic factors, and different receptor distributions can explain paradoxical stimulatory effects of high-dose zolpidem. Further studies are required to characterize subjective effects of high-dose zolpidem.

  9. Plasma Doping - Enabling Technology for High Dose Logic and Memory Applications

    International Nuclear Information System (INIS)

    Miller, T.; Godet, L.; Papasouliotis, G. D.; Singh, V.

    2008-01-01

    As logic and memory device dimensions shrink with each generation, there are more high dose implants at lower energies. Examples include dual poly gate (also referred to as counter-doped poly), elevated source drain and contact plug implants. Plasma Doping technology throughput and dopant profile benefits at these ultra high dose and lower energy conditions have been well established [1,2,3]. For the first time a production-worthy plasma doping implanter, the VIISta PLAD tool, has been developed with unique architecture suited for precise and repeatable dopant placement. Critical elements of the architecture include pulsed DC wafer bias, closed-loop dosimetry and a uniform low energy, high density plasma source. In this paper key performance metrics such as dose uniformity, dose repeatability and dopant profile control will be presented that demonstrate the production-worthiness of the VIISta PLAD tool for several high dose applications.

  10. Post-operative high dose rate brachytherapy in patients with low to intermediate risk endometrial cancer

    International Nuclear Information System (INIS)

    Pearcey, R.G.; Petereit, D.G.

    2000-01-01

    This paper investigates the outcome using different dose/fractionation schedules in high dose rate (HDR) post-operative vaginal vault radiotherapy in patients with low to intermediate risk endometrial cancer. The world literature was reviewed and thirteen series were analyzed representing 1800 cases. A total of 12 vaginal vault recurrences were identified representing an overall vaginal control rate of 99.3%. A wide range of dose fractionation schedules and techniques have been reported. In order to analyze a dose response relationship for tumor control and complications, the biologically effective doses to the tumor and late responding tissues were calculated using the linear quadratic model. A threshold was identified for complications, but not vaginal control. While dose fractionation schedules that delivered a biologically effective dose to the late responding tissues in excess of 100 Gy 3 (LQED = 60 Gy) predicted for late complications, dose fractionation schedules that delivered a modest dose to the vaginal surface (50 Gy 10 or LQED = 30 Gy) appeared tumoricidal with vaginal control rates of at least 98%. By using convenient, modest dose fractionation schedules, HDR vaginal vault - brachytherapy yields very high local control and extremely low morbidity rates. (author)

  11. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    International Nuclear Information System (INIS)

    Cantinha, Rebeca S.; Nakano, Eliana; Silva, Luanna R.S.

    2009-01-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of 60 Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD 50 obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  12. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  13. High-dose-rate brachytherapy in the treatment of uterine cervix cancer. Analysis of dose effectiveness and late complications

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Novaes, Paulo Eduardo Ribeiro dos Santos; Pellizzon, Antonio Cassio Assis; Maia, Maria Aparecida Conte; Fogarolli, Ricardo Cesar; Gentil, Andre Cavalcanti; Salvajoli, Joao Victor

    2001-01-01

    Purpose: This retrospective analysis aims to report results of patients with cervix cancer treated by external beam radiotherapy (EBR) and high-dose-rate (HDR) brachytherapy. Methods and Materials: From September 1992 to December 1996, 138 patients with FIGO Stages II and III and mean age of 56 years were treated. Median EBR to the whole pelvis was 45 Gy in 25 fractions. Parametrial boost was performed in 93% of patients, with a median dose of 14.4 Gy. Brachytherapy with HDR was performed during EBR or following its completion with a dose of 24 Gy in four weekly fractions of 6 Gy to point A. Median overall treatment time was of 60 days. Patient age, tumor stage, and overall treatment time were variables analyzed for survival and local control. Cumulative biologic effective dose (BED) at rectal and bladder reference points were correlated with late complications in these organs and dose of EBR at parametrium was correlated with small bowel complications. Results: Median follow-up time was 38 months. Overall survival, disease-free survival, and local control at 5 years was 53.7%, 52.7%, and 62%, respectively. By multivariate and univariate analysis, overall treatment time up to 50 days was the only statistically significant adverse variable for overall survival (p=0.003) and actuarial local control (p=0.008). The 5-year actuarial incidence of rectal, bladder, and small bowel late complications was 16%, 11%, and 14%, respectively. Patients treated with cumulative BED at rectum points above 110 Gy 3 and at bladder point above 125 Gy 3 had a higher but not statistically significant 5-year actuarial rate of complications at these organs (18% vs. 12%, p=0.49 and 17% vs. 9%, p=0.20, respectively). Patients who received parametrial doses larger than 59 Gy had a higher 5-year actuarial rate of complications in the small bowel; however, this was not statistically significant (19% vs. 10%, p=0.260). Conclusion: This series suggests that 45 Gy to the whole pelvis combined with

  14. Controversies in external beam and high dose rate brachytherapy of oesophageal cancer

    International Nuclear Information System (INIS)

    Sur, R.K.; Levin, V.C.; Malas, Simon; Donde, Bernard

    1994-01-01

    Various controversies in the treatment of oesophageal carcinoma with external beam radiotherapy and high dose rate intracavitary irradiation have been reviewed. Conflicting results from different parts of the world has made it difficult to optimize the radiation dose that may give the best results. More studies and longer follow-up are needed before a definite conclusion can be made on the optimization of dose. (author). 18 refs., 2 tabs

  15. Alanine-EPR dosimetry system for high industrial as well radiotherapeutic dose measurement

    International Nuclear Information System (INIS)

    Dobrovodsky, J.; Bukovjan, J.

    2005-01-01

    Slovak Institute of Metrology is developing new metrology standard for high doses, based on the alanine-EPR as a reference dosimetry system. A Bruker e-scan EPR analyser developed specifically for alanine dosimetry has improved stability of EPR measurement, especially at lower dose range. The standard e-scan system provides sensitivity below 1 Gray. After further improvement of the system and lowering of dose determination expanded uncertainty down below 1 %, its utilisation for radiotherapy field is expected (authors)

  16. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Froehlich, Georgina; Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor

    2010-01-01

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D min ) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D r ) and urethra (D u ), dose to volume of 2 cm 3 of the rectum (D 2ccm ), and 0.1 cm 3 and 1% of the urethra (D 0.1ccm and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V p ) was 27.1 cm 3 . The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D min was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D 2ccm = 49% for the rectum, D 0.1ccm = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D r , D 2ccm ) = 0.69, R(D u , D 0.1ccm ) = 0.64, R(D u , D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric

  17. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, Georgina [Semmelweis Univ., Budapest (Hungary); Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary)

    2010-07-15

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D{sub min}) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D{sub r}) and urethra (D{sub u}), dose to volume of 2 cm{sup 3} of the rectum (D{sub 2ccm}), and 0.1 cm{sup 3} and 1% of the urethra (D{sub 0.1ccm} and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V{sub p}) was 27.1 cm{sup 3}. The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D{sub min} was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D{sub 2ccm} = 49% for the rectum, D{sub 0.1ccm} = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D{sub r}, D{sub 2ccm}) = 0.69, R(D{sub u}, D{sub 0.1ccm}) = 0.64, R(D{sub u}, D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose

  18. Dosimetric evaluation of high-dose-rate interstitial brachytherapy boost treatments for localized prostate cancer.

    Science.gov (United States)

    Fröhlich, Georgina; Agoston, Péter; Lövey, József; Somogyi, András; Fodor, János; Polgár, Csaba; Major, Tibor

    2010-07-01

    To quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D(min)) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D(r)) and urethra (D(u)), dose to volume of 2 cm(3) of the rectum (D(2ccm)), and 0.1 cm(3) and 1% of the urethra (D(0.1ccm) and D1) were determined. Nonparametric correlation analysis was performed between these parameters. The median number of needles was 16, the mean prostate volume (V(p)) was 27.1 cm(3). The mean V90, V100, V150, and V200 were 99%, 97%, 39%, and 13%, respectively. The mean D90 was 109%, and the D(min) was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D(2ccm) = 49% for the rectum, D(0.1ccm) = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D(r),D(2ccm)) = 0.69, R(D(u),D0.(1ccm)) = 0.64, R(D(u),D1) = 0.23. US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric parameter is recommended.

  19. High-dose gadolinium-enhanced MRI for diagnosis of meningeal metastases

    International Nuclear Information System (INIS)

    Kallmes, D.F.; Gray, L.; Glass, J.P.

    1998-01-01

    We compared high-dose (0.3 mmol/kg) and standard-dose (0.1 mmol/kg) gadolinium-enhanced MRI for diagnosis of meningeal metastases in 12 patients with suspected meningeal metastases. They were imaged with both standard-dose and high-dose gadolinium. All patients with abnormal meningeal enhancement underwent at least one lumbar puncture for cerebrospinal fluid (CSF) cytology, while patients with normal meningeal enhancement were followed clinically. All patients with negative CSF cytology also were followed clinically. A single observer reviewed all the images, with specific attention to the enhancement pattern of the meninges. Abnormal leptomeningeal enhancement was present in three cases, and abnormal pachymeningeal enhancement in three other patients. All of these patients had abnormal CSF analyses. In two of the three cases of abnormal leptomeningeal enhancement the disease was more evident on high-dose than on standard-dose imaging; in one case the abnormal enhancement was visible only on high-dose imaging. In one of the three cases with abnormal pachymeningeal enhancement, the disease was evident prospectively only with high-dose imaging. (orig.)

  20. Preservation of Minced Meats by Using Medium and High-doses Irradiation

    International Nuclear Information System (INIS)

    Hammad, A.A.I.; Swailam, H.M.H.; Taha, S.M.A.

    2003-01-01

    The effect of medium (2.5-10 kGy) dose irradiation and high(20-70 kGy) dose irradiation on the microbiological, chemical and organoleptic properties of minced meat samples was studied. It was found that irradiation dose of only 5 kGy greatly reduced all microbial counts and completely eliminated all non-spore forming pathogenic bacteria contaminated minced meat samples. Consequently this irradiation dose extended the refrigerated (3 degree ±1) storage life of these products for more than 8 weeks. This irradiation dose almost did not affect the chemical composition, particularly the main amino acids and main fatty acids of minced meat samples. Panelists could not differentiate between irradiated minced meat samples at this dose and unirradiated samples. High doses irradiation, i.e.40 and 70 kGy were sufficient and efficient in sterilization of minced meat samples and in obtaining long-stable minced meat products (Two years) at ambient temperature. These irradiation doses slightly reduced (not more than 7%) aspartic acid, glutamic acid, methionine and lysine of minced meat. It also decreased the relative percentage of total unsaturated fatty acids by not more than 17 % . These high irradiation doses caused loss of C 18:3 and C 20:1

  1. The optimal fraction size in high-dose-rate brachytherapy: dependency on tissue repair kinetics and low-dose rate

    International Nuclear Information System (INIS)

    Sminia, Peter; Schneider, Christoph J.; Fowler, Jack F.

    2002-01-01

    Background and Purpose: Indications of the existence of long repair half-times on the order of 2-4 h for late-responding human normal tissues have been obtained from continuous hyperfractionated accelerated radiotherapy (CHART). Recently, these data were used to explain, on the basis of the biologically effective dose (BED), the potential superiority of fractionated high-dose rate (HDR) with large fraction sizes of 5-7 Gy over continuous low-dose rate (LDR) irradiation at 0.5 Gy/h in cervical carcinoma. We investigated the optimal fraction size in HDR brachytherapy and its dependency on treatment choices (overall treatment time, number of HDR fractions, and time interval between fractions) and treatment conditions (reference low-dose rate, tissue repair characteristics). Methods and Materials: Radiobiologic model calculations were performed using the linear-quadratic model for incomplete mono-exponential repair. An irradiation dose of 20 Gy was assumed to be applied either with HDR in 2-12 fractions or continuously with LDR for a range of dose rates. HDR and LDR treatment regimens were compared on the basis of the BED and BED ratio of normal tissue and tumor, assuming repair half-times between 1 h and 4 h. Results: With the assumption that the repair half-time of normal tissue was three times longer than that of the tumor, hypofractionation in HDR relative to LDR could result in relative normal tissue sparing if the optimum fraction size is selected. By dose reduction while keeping the tumor BED constant, absolute normal tissue sparing might therefore be achieved. This optimum HDR fraction size was found to be largely dependent on the LDR dose rate. On the basis of the BED NT/TUM ratio of HDR over LDR, 3 x 6.7 Gy would be the optimal HDR fractionation scheme for replacement of an LDR scheme of 20 Gy in 10-30 h (dose rate 2-0.67 Gy/h), while at a lower dose rate of 0.5 Gy/h, four fractions of 5 Gy would be preferential, still assuming large differences between tumor

  2. Effects of low priming dose irradiation on cell cycle arrest of HepG2 cells caused by high dose irradiation

    International Nuclear Information System (INIS)

    Xia Jingguang; Jin Xiaodong; Chinese Academy of Sciences, Beijing; Li Wenjian; Wang Jufang; Guo Chuanling; Gao Qingxiang

    2005-01-01

    Human hepatoma cells hepG2 were irradiated twice by 60 Co γ-rays with a priming dose of 5 cGy and a higher dose of 3 Gy performed 4h or 8h after the low dose irradiation. Effects of the priming dose irradiation on cell cycle arrest caused by high dose were examined with flow cytometry. Cells in G 2 /M phase accumulated temporarily after the 5 cGy irradiation, and proliferation of tumor cells was promoted significantly by the low dose irradiation. After the 3 Gy irradiation, G 2 phase arrest occurred, and S phase delayed temporally. In comparison with 3 kGy irradiation only, the priming dose delivered 4h prior to the high dose irradiation facilitated accumulation of hepG2 cells in G 2 /M phase, whereas the priming dose delivered 8h prior to the high dose irradiation helped the cells to overcome G 2 arrest. It was concluded that effects of the priming dose treatment on cell cycle arrest caused by high dose irradiation were dependent on time interval between the two irradiations. (authors)

  3. Mobile phone use patterns and preferences in safety net office-based buprenorphine patients.

    Science.gov (United States)

    Tofighi, Babak; Grossman, Ellie; Buirkle, Emily; McNeely, Jennifer; Gourevitch, Marc; Lee, Joshua D

    2015-01-01

    Integrating mobile phone technologies in addiction treatment is of increasing importance and may optimize patient engagement with their care and enhance the delivery of existing treatment strategies. Few studies have evaluated mobile phone and text message (TM) use patterns in persons enrolled in addiction treatment, and none have assessed the use in safety net, office-based buprenorphine practices. A 28-item, quantitative and qualitative semistructured survey was administered to opiate-dependent adults in an urban, publicly funded, office-based buprenorphine program. Survey domains included demographic characteristics, mobile phone and TM use patterns, and preferences pertaining to their recovery. Surveyors approached 73 of the 155 eligible subjects (47%); 71 respondents completed the survey. Nearly all participants reported mobile phone ownership (93%) and TM use (93%), and most reported "very much" or "somewhat" comfort sending TM (79%). Text message contact with 12-step group sponsors, friends, family members, and counselors was also described (32%). Nearly all preferred having their providers' mobile phone number (94%), and alerting the clinic via TM in the event of a potential relapse to receive both supportive TM and a phone call from their buprenorphine provider was also well received (62%). Mobile phone and TM use patterns and preferences among this sample of office-based buprenorphine participants highlight the potential of adopting patient-centered mobile phone-based interventions in this treatment setting.

  4. Comparison of efficacy between buprenorphine and tramadol in the detoxification of opioid (heroin)-dependent subjects.

    Science.gov (United States)

    Chawla, Jatinder Mohan; Pal, Hemraj; Lal, Rakesh; Jain, Raka; Schooler, Nina; Balhara, Yatan Pal Singh

    2013-01-01

    Tramadol is a synthetic opiate and a centrally acting weak m-opioid receptor agonist. The potential advantages of tramadol include ease of administration, low abuse potential, and being nonscheduled. This study compared tramadol and buprenorphine for controlling withdrawal symptoms in patients with opioid dependence syndrome. Consenting male subjects between 20 and 45 years of age who fulfilled the ICD-10-DCR criteria for opiate dependence syndrome were randomly assigned in a double-blind, double-dummy placebo-controlled trial for detoxification. Those with multiple drug dependence, abnormal cardiac, renal and hepatic functions, psychosis, or organic mental illness were excluded. Assessments included Subjective Opiate Withdrawal Scale (SOWS), Objective Opiate Withdrawal Scale (OOWS), Visual Analog Scale (VAS), and Side Effect Check List. Subjects were evaluated daily and study duration was 10 days. Sixty two subjects were enrolled. The mean SOWS and OOWS and VAS were significantly lower in the buprenorphine group on second and third day of detoxification as compared to the tramadol group. Although the retention rate was higher for buprenorphine group throughout the study, when compared with tramadol the difference was not significant on any day. Three subjects in the tramadol group had seizures. Tramadol was found to have limited detoxification efficacy in moderate to severe opioid withdrawal and substantial risk of seizures as compared to buprenorphine. Further studies are warranted to examine its efficacy in mild opioid withdrawal symptoms and its potential use in outpatient settings where its administration advantages may be valuable.

  5. The Presence or Absence of QTc Prolongation in Buprenorphine-Naloxone Among Youth with Opioid Dependence

    Science.gov (United States)

    Poole, Sabrina A.; Pecoraro, Anna; Subramaniam, Geetha; Woody, George; Vetter, Victoria L

    2015-01-01

    Objective To evaluate buprenorphine-naloxone effects on the QTc in youth with opioid dependence. Buprenorphine is a partial agonist that is an effective treatment for opioid dependence. Compared to methadone it has a lower risk of QTc prolongation in adults but is less well studied in youth. It may also reduce the risk for torsades de pointes (TdP) an uncommon variant of polymorphic ventricular tachycardia, that can result in syncope, ventricular fibrillation, and sudden death. Methods Secondary analysis of ECG data from 95 subjects who participated in a multi-site trial for youth with opioid dependence. Subjects were randomized to a 2-week (DETOX), or a 12-week course of buprenorphine-naloxone (BUP). 12-lead ECGs were done at baseline, weeks 4 and 12, and QTc intervals were hand measured and calculated using Bazett's formula. Increases > 60 milliseconds (ms) were considered clinically significant, and readings > 450 ms (males) and 470 ms (females) indicated a prolonged QTc. Results Mean QTc intervals were higher for BUP than DETOX participants at baseline, week 4, and week 12 (p = 0.045), and females had longer mean QTc intervals than males (p DETOX patients. Minimal changes in the QTc were seen at 4 and 12-weeks in a few patients in both groups. There was no evidence that buprenorphine-naloxone alone increased the QTc to a level that increased the risk for TdP. PMID:26690291

  6. Presence or Absence of QTc Prolongation in Buprenorphine-Naloxone Among Youth With Opioid Dependence.

    Science.gov (United States)

    Poole, Sabrina A; Pecoraro, Anna; Subramaniam, Geetha; Woody, George; Vetter, Victoria L

    2016-01-01

    The aim of the study was to evaluate buprenorphine-naloxone effects on the QTc in youth with opioid dependence. Buprenorphine is a partial agonist that is an effective treatment for opioid dependence. Compared with methadone, it has a lower risk of QTc prolongation in adults, but is less studied in the youth. It may also reduce the risk of torsades de pointes (TdP)--an uncommon variant of polymorphic ventricular tachycardia--that can result in syncope, ventricular fibrillation, and sudden death. Secondary analysis of the electrocardiogram data from 95 individuals who participated in a multisite trial for youth with opioid dependence. The participants were randomized to a 2-week (DETOX) or a 12-week course of buprenorphine-naloxone (BUP). At baseline, 12-lead electrocardiograms were done at weeks 4 and 12, and QTc intervals were hand-measured and calculated using Bazett formula. Increases above 60 milliseconds were considered clinically significant, and readings above 450 milliseconds (in men) and 470 milliseconds (in women) indicated a prolonged QTc. Mean QTc intervals were higher for BUP than for DETOX participants at baseline, week 4, and week 12 (P = 0.045), and women had longer mean QTc intervals than men (P DETOX patients. Minimal changes in the QTc were seen at 4 and 12 weeks in a few patients in both groups. There was no evidence that buprenorphine-naloxone alone increased the QTc to a level that increased the risk for TdP.

  7. Neuropsychological functioning in buprenorphine maintained patients versus abstinent heroin abusers on naltrexone hydrochloride therapy.

    Science.gov (United States)

    Messinis, Lambros; Lyros, Epameinondas; Andrian, Virginia; Katsakiori, Paraskevi; Panagis, George; Georgiou, Vasileios; Papathanasopoulos, Panagiotis

    2009-10-01

    Methadone and buprenorphine are among the most widely employed pharmacological treatments currently available for opioid addiction. Cognitive effects of buprenorphine in abstinent heroin abusers are nevertheless far from being understood. Neuropsychological performance of 18 buprenorphine-maintained patients (BMP) was evaluated relative to that of 32 currently abstinent heroin abusers on naltrexone hydrochloride therapy (FHAN), and 34 non-drug dependent controls. The three groups were demographically balanced. Clinical groups reported histories of similar patterns of drug use and had increased periods of abstinence from any illicit substance use including heroin. The BMP group performed poorer than controls on the RAVLT (encoding and delayed recall of verbal information), CTT (conceptual flexibility, executive functions) and the RBANS figure copy (visual perception) and delayed recall of visual information. There were no significant differences in any of the cognitive measures between the BMP and FHAN groups or between the FHAN group and controls. Furthermore, the non-differing percentage of abnormal cases between the two patient groups led us to infer that treatment with either BPM or FHAN is not accompanied by qualitative differences in the cognitive profiles of these patients. Overall, results suggest that treatment with naltrexone in abstinent heroin abusers may result in less impairment of cognitive functions compared to treatment with buprenorphine. These findings are relevant for improved prognosis and treatment strategies in opioid dependence.

  8. Evaluation of sedation for standing clinical procedures in horses using detomidine combined with buprenorphine.

    Science.gov (United States)

    Taylor, Polly; Coumbe, Karen; Henson, Frances; Scott, David; Taylor, Alan

    2014-01-01

    To examine the effect of including buprenorphine with detomidine for sedation of horses undergoing clinical procedures. Partially blinded, randomised, prospective clinical field trial. Eighty four client-owned horses scheduled for minor surgery or diagnostic investigation under standing sedation. The effects of buprenorphine (5 μg kg(-1) ) (Group B, n = 46) or placebo (5% glucose solution) (Group C, n = 38) in combination with detomidine (10 μg kg(-1) ) were compared in standing horses undergoing minor clinical procedures. The primary outcome measure was successful completion of the procedure. The degree of sedation and ataxia were scored using simple descriptive scales. Heart and respiratory rates were recorded at 15-30 minute intervals. Parametric data from each group were compared using anova or t-test and non parametric data using the Mann-Whitney U test. The procedure was carried out successfully in 91% of Group B and 63% of Group C (p detomidine, increased after buprenorphine but not glucose administration, was more profound in group B and lasted longer (60 versus 30 minutes) p detomidine 10 and 20 μg kg(-1) with minor side effects similar to other alpha2 agonist/opioid combinations. Detomidine-buprenorphine sedation is suitable for standing procedures in horses. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  9. Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi

    2016-11-08

    Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.

  10. High Throughput Determinations of Critical Dosing Parameters (IVIVE workshop)

    Science.gov (United States)

    High throughput toxicokinetics (HTTK) is an approach that allows for rapid estimations of TK for hundreds of environmental chemicals. HTTK-based reverse dosimetry (i.e, reverse toxicokinetics or RTK) is used in order to convert high throughput in vitro toxicity screening (HTS) da...

  11. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    Science.gov (United States)

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (agedphenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  12. Applichation of the sulphate ceric dosimetric in the high doses range

    International Nuclear Information System (INIS)

    Prieto Miranda, F.

    1991-01-01

    The ceric-cerous dosimetric system is one of the system more employed in the high dose dosimetry. The spectrophotometric procedure to measure the ceric-concentration is an usual analityc method to determine the absorbed dose. On the other hand, due at increase employ of the irradiation process control. In this paper is realized the ceric-cerous dosimetric calibration in the dose range of 0,6 - 5 kGy and the application in the irradiation process control to differents absorbed dose values

  13. Dose for background radioactivity in areas with high radioactivity levels in the Pinar del Rio province

    International Nuclear Information System (INIS)

    Alcaide Orpi, J.; Oliveira Acosta, J.; Valdes Hernadez, G.M.; Leal Ramirez, M.R.; Blanco Jorrin, N.

    1998-01-01

    The objective the work is to know the areas with high natural radiation doses, for they were used it the data obtained by the studies it has more than enough favorability for radioactive minerals carried out in different regions to the Pinar del Rio province in the 1986 to 1993 years and the doses calculations they were carried out according to the effective methodology

  14. High-dose chemotherapy : studies on supportive care, quality of life and late effects of treatment

    NARCIS (Netherlands)

    Nieboer, Peter

    2008-01-01

    Drug resistance is a major problem in the treatment of malignancies. Based on steep dose-response relationship for certain chemotherapeutic drugs in vitro on tumor cell survival, high-dose chemotherapy was considered of interest for the treatment of malignancies. Introduction of autologous

  15. Extra-high doses detected in the enamel of human teeth in the Techa riverside region

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A., E-mail: ElenaA.Shishkina@gmail.com [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Degteva, M.O.; Tolstykh, E.I.; Volchkova, A. [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Ivanov, D.V. [Institute of Metal Physics, Russian Academy of Sciences, 18 S. Kovalevsky Str, 620041 Yekaterinburg (Russian Federation); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, D-85764 Neuherberg (Germany); Della Monaca, S. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Regina Elena, 00144 Rome (Italy); Fattibene, P. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Nazionale di Fisica Nucleare, 00161 Rome (Italy)

    2011-09-15

    During the long-term study of tooth enamel by EPR dosimetry for population exposed to radiation due to contamination of the Techa River, it was found out that for some of the tooth donors the dose accumulated in tooth enamel could be as high as several tens of Gy. Such doses were absorbed only in tooth enamel and they should not be associated with exposures to other organs or the whole body. The nature of such doses was discussed in a number of previous papers where it was shown that the source of such doses is {sup 90}Sr incorporated in the calcified dental tissues. However, among specialists in radiation dosimetry who were not involved in the biokinetic studies, the nature and dosimetric significance of extra-high doses in tooth enamel are still raising questions. The aim of the current paper is to summarize the accumulated information on extra-high doses in the teeth of the Techa riverside residents, describe the dose levels observed, explain the nature of extra-high doses in the enamel and discuss their informative value. The paper includes an overview of already published findings and an analysis of information collected in the data bank of the Urals Research Center for Radiation Medicine (URCRM), Chelyabinsk, Russia, which has not been published before.

  16. Maternal high-dose folic acid during pregnancy and asthma medication in the offspring

    NARCIS (Netherlands)

    Zetstra-van der Woude, Priscilla A.; De Walle, Hermien E. K.; Hoek, Annemieke; Bos, H. Jens; Boezen, H. Marike; Koppelman, Gerhard H.; de Jong-van den Berg, Lolkje T. W.; Scholtens, Salome

    2014-01-01

    Purpose Low-dose folic acid supplementation (0.5 mg) taken during pregnancy has been associated with an increased risk for childhood asthma. The effect of high-dose folic acid (5 mg) advised to women at risk for having a child with neural tube defect has not been assessed so far. Our aim was to

  17. The effects of high dose and highly fractionated radiation on distraction osteogenesis in the murine mandible

    International Nuclear Information System (INIS)

    Monson, Laura A; Cavaliere, Christi M; Deshpande, Sagar S; Ayzengart, Alexander L; Buchman, Steven R

    2012-01-01

    The ability of irradiated tissue to support bony growth remains poorly defined, although there are anecdotal cases reported showing mixed results for the use of mandibular distraction osteogenesis after radiation for head and neck cancer. Many of these reports lack objective measures that would allow adequate analysis of outcomes or efficacy. The purpose of this experiment was to utilize a rat model of mandibular distraction osteogenesis after high dose and highly fractionated radiation therapy and to evaluate and quantify distracted bone formation under these conditions. Male Sprague–Dawley rats underwent 12 fractions of external beam radiation (48 Gray) of the left mandible. Following a two week recovery period, an external frame distractor was applied and gradual distraction of the mandible was performed. Tissue was harvested after a twenty-eight day consolidation period. Gross, radiologic and histological evaluations were undertaken. Those animals subjected to pre-operative radiation showed severe attenuation of bone formation including bone atrophy, incomplete bridging of the distraction gap, and gross bony defects or non-union. Although physical lengthening was achieved, the irradiated bone consistently demonstrated marked damaging effects on the normal process of distraction osteogenesis. This murine model has provided reliable evidence of the injurious effects of high dose radiation on bone repair and regeneration in distraction osteogenesis utilizing accurate and reproducible metrics. These results can now be used to assist in the development of therapies directed at mitigating the adverse consequences of radiation on the regeneration of bone and to optimize distraction osteogenesis so it can be successfully applied to post-oncologic reconstruction

  18. High versus standard dose caffeine for apnoea: a systematic review

    NARCIS (Netherlands)

    Vliegenthart, Roos; Miedema, Martijn; Hutten, Gerard J.; van Kaam, Anton H.; Onland, Wes

    2018-01-01

    Placebo-controlled trials have shown that caffeine is highly effective in treating apnoea of prematurity and reduces the risk of bronchopulmonary dysplasia (BPD) and neurodevelopmental impairment (NDI). To identify, appraise and summarise studies investigating the modulating effect of different

  19. Monitoring of high-radiation areas for the assessment of operational and body doses

    International Nuclear Information System (INIS)

    Chen, T.J.; Tung, C.J.; Yeh, W.W.; Liao, R.Y.

    2004-01-01

    The International Commission on Radiological Protection (ICRP) recommended a system of dose limits for the protection of ionizing radiation. This system was established based on the effective dose, E, and the equivalent dose to an organ or tissue, H T , to assess stochastic and deterministic effects. In radiation protection monitoring for external radiation, operational doses such as the deep dose equivalent index, H I,d , shallow dose equivalent index, H I,s , ambient dose equivalent [1,4-6], H*, directional dose equivalent, H', individual dose equivalent-penetrating, H p , and individual dose equivalent-superficial, H s , are implemented. These quantities are defined in an International Commission on Radiation Units and Measurements (ICRU) sphere and in an anthropomorphic phantom under simplified irradiation conditions. They are useful when equivalent doses are below the corresponding limits. In the case of equivalent doses far below the limits, the exposure or air kerma is commonly applied. For workers exposed to high levels of radiation, accurate assessments of effective doses and equivalent doses may be needed in order to acquire legal and health information. In the general principles of monitoring for radiation protection of workers, ICRP recommended that: 'A graduated response is advocated for the monitoring of the workplace and for individual monitoring - graduated in the sense that a greater degree of monitoring is deemed to be necessary as doses increase of as unpredictability increases. Gradually more complex or realistic procedures should be adopted as doses become higher. Thus, at low dose equivalents (corresponding say to those within Working Condition B) dosimetric quantities might be used directly to assess exposure, since accuracy is not crucial. At intermediate dose equivalents (corresponding say to Working Condition A and slight overexposures) somewhat greater accuracy is warranted, and the conversion coefficients from dosimetric to radiation

  20. Regular self-microstructuring on CR39 using high UV laser dose

    International Nuclear Information System (INIS)

    Parvin, P.; Refahizadeh, M.; Mortazavi, S.Z.; Silakhori, K.; Mahdiloo, A.; Aghaii, P.

    2014-01-01

    The UV laser induced replicas in the form of self-lining microstructures are created by high dose (with high fluence) ArF laser irradiation on CR39. Microstructures as the self-induced contours, in the form of concentric circles, appear when the laser fluence is well above the ablation threshold. It leads to the regular periodic parallel lines, i.e. circles with large radii having spatial separation 100–200 nm and line width 300–600 nm, where the number of shots increases to achieve higher UV doses. The surface wettability is also investigated after laser texturing to exhibit that a notable hydrophilicity takes place at high doses.

  1. Erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA

    International Nuclear Information System (INIS)

    Speight, E.L.; Farr, P.M.

    1994-01-01

    In PUVA treatment of psoriasis, clinical observation suggests that uninvolved skin is more susceptible to PUVA erythema than lesions of psoriasis. If this is the case, then the efficacy of PUVA treatment might be increased by using localized high-dose UVA restricted to lesional skin. We have therefore studied the erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA and, for comparison, the erythemal response to UVB. This study demonstrates that psoriasis may clear rapidly, without burning, using high-dose UVA. Availability of a suitable irradiation apparatus would allow rapid and effective PUVA treatment to be used for localized, resistant disease. (author)

  2. Global dose to man from proposed NNTRP high altitude nuclear tests

    International Nuclear Information System (INIS)

    Peterson, K.R.

    1975-05-01

    Radionuclide measurements from past high altitude nuclear testing have enabled development of a model to estimate surface deposition and doses from 400 kt of fission products injected in winter within the Pacific Test Area at altitudes in excess of 50 km. The largest 30-year average dose to man is about 10 millirem and occurs at 30 0 to 50 0 N latitude. The principal contributor to this dose is external gamma radiation from gross fission products. Individual doses from 90 Sr via the forage-cow-milk pathway and 137 Cs via the pasture-meat pathway are about 1/5 the gross fission product doses. The global 30-year population dose is 3 x 10 7 person-rem, which compares with a 30-year natural background population dose of 1 X 10 10 person-rem. Due in large part to the global distribution of population, over 98 percent of the global person-rem from the proposed high altitude tests is received in the Northern Hemisphere, while about 75 percent of the total population dose occurs within the 30 0 --50 0 N latitude belt. Detonations in summer would decrease the global dose by about a factor of three. (U.S.)

  3. Hypertonic Saline in Conjunction with High-Dose Furosemide Improves Dose-Response Curves in Worsening Refractory Congestive Heart Failure.

    Science.gov (United States)

    Paterna, Salvatore; Di Gaudio, Francesca; La Rocca, Vincenzo; Balistreri, Fabio; Greco, Massimiliano; Torres, Daniele; Lupo, Umberto; Rizzo, Giuseppina; di Pasquale, Pietro; Indelicato, Sergio; Cuttitta, Francesco; Butler, Javed; Parrinello, Gaspare

    2015-10-01

    Diuretic responsiveness in patients with chronic heart failure (CHF) is better assessed by urine production per unit diuretic dose than by the absolute urine output or diuretic dose. Diuretic resistance arises over time when the plateau rate of sodium and water excretion is reached prior to optimal fluid elimination and may be overcome when hypertonic saline solution (HSS) is added to high doses of furosemide. Forty-two consecutively hospitalized patients with refractory CHF were randomized in a 1:1:1 ratio to furosemide doses (125 mg, 250 mg, 500 mg) so that all patients received intravenous furosemide diluted in 150 ml of normal saline (0.9%) in the first step (0-24 h) and the same furosemide dose diluted in 150 ml of HSS (1.4%) in the next step (24-48 h) as to obtain 3 groups as follows: Fourteen patients receiving 125 mg (group 1), fourteen patients receiving 250 mg (group 2), and fourteen patients receiving 500 mg (group 3) of furosemide. Urine samples of all patients were collected at 30, 60, and 90 min, and 3, 4, 5, 6, 8, and 24 h after infusion. Diuresis, sodium excretion, osmolality, and furosemide concentration were evaluated for each urine sample. After randomization, 40 patients completed the study. Two patients, one in group 2 and one in group 3 dropped out. Patients in group 1 (125 mg furosemide) had a mean age of 77 ± 17 years, 43% were male, 6 (43%) had heart failure with a preserved ejection fraction (HFpEF), and 64% were in New York Heart Association (NYHA) class IV; the mean age of patients in group 2 (250 mg furosemide) was 80 ± 8.1 years, 15% were male, 5 (38%) had HFpEF, and 84% were in NYHA class IV; and the mean age of patients in group 3 (500 mg furosemide) was 73 ± 12 years, 54% were male, 6 (46%) had HFpEF, and 69% were in NYHA class IV. HSS added to furosemide increased total urine output, sodium excretion, urinary osmolality, and furosemide urine delivery in all patients and at all time points. The percentage increase was 18,14, and

  4. A randomized clinical trial of buprenorphine for prisoners: Findings at 12-months post-release.

    Science.gov (United States)

    Gordon, Michael S; Kinlock, Timothy W; Schwartz, Robert P; O'Grady, Kevin E; Fitzgerald, Terrence T; Vocci, Frank J

    2017-03-01

    This study examined whether starting buprenorphine treatment prior to prison and after release from prison would be associated with better drug treatment outcomes and whether males and females responded differently to the combination of in-prison treatment and post-release service setting. Study design was a 2 (In-Prison Treatment: Condition: Buprenorphine Treatment: vs. Counseling Only)×2 [Post-Release Service Setting Condition: Opioid Treatment: Program (OTP) vs. Community Health Center (CHC)]×2 (Gender) factorial design. The trial was conducted between September 2008 and July 2012. Follow-up assessments were completed in 2014. Participants were recruited from two Baltimore pre-release prisons (one for men and one for women). Adult pre-release prisoners who were heroin-dependent during the year prior to incarceration were eligible. Post-release assessments were conducted at 1, 3, 6, and 12-month following prison release. Participants (N=211) in the in-prison treatment condition effect had a higher mean number of days of community buprenorphine treatment compared to the condition in which participants initiated medication after release (P=0.005). However, there were no statistically significant hypothesized effects for the in-prison treatment condition in terms of: days of heroin use and crime, and opioid and cocaine positive urine screening test results (all Ps>0.14) and no statistically significant hypothesized gender effects (all Ps>0.18). Although initiating buprenorphine treatment in prison compared to after-release was associated with more days receiving buprenorphine treatment in the designated community treatment program during the 12-months post-release assessment, it was not associated with superior outcomes in terms of heroin and cocaine use and criminal behavior. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Cost-effectiveness of buprenorphine and naltrexone treatments for heroin dependence in Malaysia.

    Science.gov (United States)

    Ruger, Jennifer Prah; Chawarski, Marek; Mazlan, Mahmud; Ng, Nora; Schottenfeld, Richard

    2012-01-01

    To aid public health policymaking, we studied the cost-effectiveness of buprenorphine, naltrexone, and placebo interventions for heroin dependence in Malaysia. We estimated the cost-effectiveness ratios of three treatments for heroin dependence. We used a microcosting methodology to determine fixed, variable, and societal costs of each intervention. Cost data were collected from investigators, staff, and project records on the number and type of resources used and unit costs; societal costs for participants' time were estimated using Malaysia's minimum wage. Costs were estimated from a provider and societal perspective and reported in 2004 US dollars. Muar, Malaysia. 126 patients enrolled in a randomized, double-blind, placebo-controlled clinical trial in Malaysia (2003-2005) receiving counseling and buprenorphine, naltrexone, or placebo for treatment of heroin dependence. Primary outcome measures included days in treatment, maximum consecutive days of heroin abstinence, days to first heroin use, and days to heroin relapse. Secondary outcome measures included treatment retention, injection drug use, illicit opiate use, AIDS Risk Inventory total score, and drug risk and sex risk subscores. Buprenorphine was more effective and more costly than naltrexone for all primary and most secondary outcomes. Incremental cost-effectiveness ratios were below $50 for primary outcomes, mostly below $350 for secondary outcomes. Naltrexone was dominated by placebo for all secondary outcomes at almost all endpoints. Incremental treatment costs were driven mainly by medication costs, especially the price of buprenorphine. Buprenorphine appears to be a cost-effective alternative to naltrexone that might enhance economic productivity and reduce drug use over a longer term.

  6. Cost-effectiveness of buprenorphine and naltrexone treatments for heroin dependence in Malaysia.

    Directory of Open Access Journals (Sweden)

    Jennifer Prah Ruger

    Full Text Available To aid public health policymaking, we studied the cost-effectiveness of buprenorphine, naltrexone, and placebo interventions for heroin dependence in Malaysia.We estimated the cost-effectiveness ratios of three treatments for heroin dependence. We used a microcosting methodology to determine fixed, variable, and societal costs of each intervention. Cost data were collected from investigators, staff, and project records on the number and type of resources used and unit costs; societal costs for participants' time were estimated using Malaysia's minimum wage. Costs were estimated from a provider and societal perspective and reported in 2004 US dollars.Muar, Malaysia.126 patients enrolled in a randomized, double-blind, placebo-controlled clinical trial in Malaysia (2003-2005 receiving counseling and buprenorphine, naltrexone, or placebo for treatment of heroin dependence.Primary outcome measures included days in treatment, maximum consecutive days of heroin abstinence, days to first heroin use, and days to heroin relapse. Secondary outcome measures included treatment retention, injection drug use, illicit opiate use, AIDS Risk Inventory total score, and drug risk and sex risk subscores.Buprenorphine was more effective and more costly than naltrexone for all primary and most secondary outcomes. Incremental cost-effectiveness ratios were below $50 for primary outcomes, mostly below $350 for secondary outcomes. Naltrexone was dominated by placebo for all secondary outcomes at almost all endpoints. Incremental treatment costs were driven mainly by medication costs, especially the price of buprenorphine.Buprenorphine appears to be a cost-effective alternative to naltrexone that might enhance economic productivity and reduce drug use over a longer term.

  7. Pharmacokinetics and Paw Withdrawal Pressure in Female Guinea Pigs (Cavia porcellus) Treated with Sustained-Release Buprenorphine and Buprenorphine Hydrochloride.

    Science.gov (United States)

    Smith, Brian J; Wegenast, Daniel J; Hansen, Ryan J; Hess, Ann M; Kendall, Lon V

    2016-11-01

    Providing appropriate analgesia is essential in minimizing pain and maintaining optimal animal care and welfare in laboratory animals. Guinea pigs are common animal models in biomedical research, often requiring analgesic support. Here we evaluated the pharmacokinetics and efficacy of a sustained-release formulation of buprenorphine (Bup-SR) in this species. Guinea pigs (n = 7 each group) received either Bup-HCl (0.05 mg/kg BID for 3 d) or Bup-SR (0.3 mg/kg once). Plasma collection and measurement of paw-withdrawal pressure (PWP) was conducted at 0, 1, 3, 6, 12, 26, 48, and 72 h after treatment. Plasma levels of Bup-HCl peaked at 2331 pg/mL at 1 h after administration and declined to 165 pg/mL by 12 h. Plasma concentrations of Bup-SR peaked at 1344 pg/mL at 26 h after administration and declined to 429 pg/mL by 48 h. The PWP of the Bup-HCltreated guinea pigs peaked at 674 g at 1 h and declined to 402 g at 6 h, whereas that of Bup-SRtreated guinea pigs at 1 h was 361 g, 555 g at 6 h (significantly higher than that after Bup-HCl), and peaked at 680 g at 12 h. The PWP of both treatments was similar from 24 to 72 h and ranged from 348 to 450 g. The plasma concentration and PWP showed good correlation. These results suggest that Bup-SR provides consistent analgesia equivalent to that of Bup-HCl for a prolonged period of time and that Bup-SR is an alternative method of analgesia in guinea pigs.

  8. Radiobiological equivalent of low/high dose rate brachytherapy and evaluation of tumor and normal responses to the dose.

    Science.gov (United States)

    Manimaran, S

    2007-06-01

    The aim of this study was to compare the biological equivalent of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy in terms of the more recent linear quadratic (LQ) model, which leads to theoretical estimation of biological equivalence. One of the key features of the LQ model is that it allows a more systematic radiobiological comparison between different types of treatment because the main parameters alpha/beta and micro are tissue-specific. Such comparisons also allow assessment of the likely change in the therapeutic ratio when switching between LDR and HDR treatments. The main application of LQ methodology, which focuses on by increasing the availability of remote afterloading units, has been to design fractionated HDR treatments that can replace existing LDR techniques. In this study, with LDR treatments (39 Gy in 48 h) equivalent to 11 fractions of HDR irradiation at the experimental level, there are increasing reports of reproducible animal models that may be used to investigate the biological basis of brachytherapy and to help confirm theoretical predictions. This is a timely development owing to the nonavailability of sufficient retrospective patient data analysis. It appears that HDR brachytherapy is likely to be a viable alternative to LDR only if it is delivered without a prohibitively large number of fractions (e.g., fewer than 11). With increased scientific understanding and technological capability, the prospect of a dose equivalent to HDR brachytherapy will allow greater utilization of the concepts discussed in this article.

  9. Treatment of carcinoma of uterine cervix with high-dose-rate intracavitary irradiation using Ralstron

    International Nuclear Information System (INIS)

    Suh, C.O.; Kim, G.E.; Loh, J.J.K.

    1988-01-01

    From May 1979 through December 1981, a total of 530 patients with carcinoma of the uterine cervix were treated with radiation therapy with curative intent. Of the 530 patients, 365 were treated with a high-dose-rate remote-controlled afterloading system (RALS) using a cobalt source, and 165 patients received a low dose rate using a radium source. External pelvic irradiation with a total of 40-50 Gy to the whole pelvis followed by intracavitary radiation (ICR) with a total dose of 30-39 Gy in ten to 13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rate with high-dose-rate ICR by stage was as follows: stage I:82.7% (N = 19) stage II:69.6% (N = 184), and stage III:52.2% (N = 156). The above results were comparable with those with conventional low-dose-rate ICR treatment, and late complications were far less. The application of high-dose-rate ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually none as compared with that of low-dose-rate ICR. Within a given period of time, more patients can be treated with high-dose-rate ICR because of the short treatment time. The authors therefore conclude that high-dose-rate ICR is suitable for a cancer center where a large number of patients are to be treated

  10. Low- and high-dose laser irradiation effects on cell migration and destruction

    Science.gov (United States)

    Layton, Elivia; Gallagher, Kyra A.; Zukerman, Sara; Stevens, Brianna; Zhou, Feifan; Liu, Hong; Chen, Wei R.

    2018-02-01

    Metastases are the cause of more than 90 percent of cancer-related deaths. Current treatment methods, including chemotherapy, radiation, and surgery, fail to target the metastases effectively. One potential treatment for metastatic cancer is laser immunotherapy (LIT). LIT combines the use of a photothermal laser with an immunoadjuvant, Glycated Chitosan (GC). GC combined with single-walled carbon nanotubes (SWNTs) has proven to be a viable alternative to traditional cancer treatment methods, when under irradiation of laser with appropriate wavelength. In this study, the effects of low dose and high dose laser irradiation on metastatic pancreatic cancer cell migration were observed. It was found that low dose irradiation increased the migration rate, but the high dose irradiation significantly decreased the migration rate of the cancer cells. When using LIT, the goal is to kill tumor cells and to prompt the correct immune response. If the tumor were irradiated with a low dose, it would promote metastasis. If the dose of irradiation were too high, it would destroy the entire tumor and the immune response would not recognize the tumor. Therefore, the laser dose plays an important role in LIT, particularly when using SWNT as light absorbing agent. Our results from this study will delineate the optimal laser irradiation dose for destroying tumor cells and at the same time preserve and release tumor antigens as a precursor of antitumor immune response.

  11. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered