WorldWideScience

Sample records for high dose animals

  1. A graphical review of radiogenic animal cancer data using the 'dose and dose-rate map'

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Hoshi, Yuko; Sakai, Kazuo

    2008-01-01

    We have been investigating the effects of low dose or low dose rate irradiation on mice, using our low dose-rate irradiation facilities. In these studies, we found that the effects were highly dependent on both total dose and dose rate. To show this visually, we proposed the 'dose/dose rate map', and plotted the results of our laboratory and our co-workers. The map demonstrated that dose/dose rate plane could be divided into three areas; 1) An area where harmful effects are observed, 2) An area where no harmful effects are observed, and 3) Another area, between previous two areas, where certain protective functions are enhanced. As this map would be a powerful tool to find some trend among the vast numbers of data relating the biological effects of ionizing radiation, we have developed a computer program which plots the collected data on the dose/dose rate map sorting by experimental conditions. In this study, we graphically reviewed and analyzed the data relating to the lifespan studies of animals with a view to determining the relationships between doses and dose rates of ionizing radiation and cancer incidence. The data contains about 800 sets of experiments, which concerns 187,000 animals exposed to gamma ray or X-ray and their 112,000 controls, and total of about 30,000 cancers in exposed animals and 14,000 cancers in controls. About 800 points of data were plotted on the dose/dose rate map. The plot showed that 1) The divided three areas in the dose/dose rate map were generally confirmed by these 800 points of data, and 2) In some particular conditions, e.g. sarcoma by X-rays, the biologically effective area is extended to relatively high dose/dose rate area. (author)

  2. In an animal model nephrogenic systemic fibrosis cannot be induced by intraperitoneal injection of high-dose gadolinium based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Langer, R.D., E-mail: rlanger@uaeu.ac.ae [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Lorke, D.E. [Florida International University, Miami, FL (United States); Neidl van Gorkom, K.F. [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Petroianu, G. [Florida International University, Miami, FL (United States); Azimullah, S.; Nurulain, S.M.; Singh, S. [Faculty of Medicine and Health Sciences (FMHS), United Arab Emirates University, Al Ain (United Arab Emirates); Fuchsjäger, M. [Al Ain Hospital, MUV-VAMED, Al Ain (United Arab Emirates)

    2012-10-15

    Aim and objective: Nephrogenic systemic fibrosis (NSF) has been reported in humans to be most likely induced by gadolinium based contrast agents (GBCA), namely by gadodiamide, gadopentetate dimeglumine, and gadoversetamide, rarely by other GBCA. The pathogenesis of NSF remains unclear; different hypotheses are under discussion. The objective of the study is to assess if in the animal model human-like NSF changes can be induced by high-dose, intraperitoneal GBCA injections over four weeks. Materials and methods: After approval by the institutional animal ethics committee, six rats each were randomly assigned to groups, and treated with seven different GBCA. Intraperitoneal (IP) injections – proven in the animal model to be effective – were chosen to prolong the animals’ exposure to the respective GBCA. GBCA doses of previous intravenous (IV) animal studies were applied. After five weeks all rats were sacrificed. Sham controls were treated with IP saline injections, employing the same regimen. Results: No findings comparable with human NSF were observed in all animals after IP treatment with all seven GBCA at daily doses of 2.5 and 5.0 mmol/kg body weight (BW). No histopathological abnormalities of all examined organs were noted. Weight loss was stated in weeks three and four with GBCA injections at doses of 5.0 mmol/kg BW, but rats regained weight after cessation of GBCA treatment. Conclusions: NSF-comparable pathological findings could not be induced by high dose intraperitoneal injection of seven GBCA.

  3. In an animal model nephrogenic systemic fibrosis cannot be induced by intraperitoneal injection of high-dose gadolinium based contrast agents

    International Nuclear Information System (INIS)

    Langer, R.D.; Lorke, D.E.; Neidl van Gorkom, K.F.; Petroianu, G.; Azimullah, S.; Nurulain, S.M.; Singh, S.; Fuchsjäger, M.

    2012-01-01

    Aim and objective: Nephrogenic systemic fibrosis (NSF) has been reported in humans to be most likely induced by gadolinium based contrast agents (GBCA), namely by gadodiamide, gadopentetate dimeglumine, and gadoversetamide, rarely by other GBCA. The pathogenesis of NSF remains unclear; different hypotheses are under discussion. The objective of the study is to assess if in the animal model human-like NSF changes can be induced by high-dose, intraperitoneal GBCA injections over four weeks. Materials and methods: After approval by the institutional animal ethics committee, six rats each were randomly assigned to groups, and treated with seven different GBCA. Intraperitoneal (IP) injections – proven in the animal model to be effective – were chosen to prolong the animals’ exposure to the respective GBCA. GBCA doses of previous intravenous (IV) animal studies were applied. After five weeks all rats were sacrificed. Sham controls were treated with IP saline injections, employing the same regimen. Results: No findings comparable with human NSF were observed in all animals after IP treatment with all seven GBCA at daily doses of 2.5 and 5.0 mmol/kg body weight (BW). No histopathological abnormalities of all examined organs were noted. Weight loss was stated in weeks three and four with GBCA injections at doses of 5.0 mmol/kg BW, but rats regained weight after cessation of GBCA treatment. Conclusions: NSF-comparable pathological findings could not be induced by high dose intraperitoneal injection of seven GBCA

  4. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A. Joe [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Loo, Billy W., E-mail: BWLoo@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States); Maxim, Peter G., E-mail: PMaxim@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California (United States)

    2017-01-01

    Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.

  5. Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator.

    Science.gov (United States)

    Schüler, Emil; Trovati, Stefania; King, Gregory; Lartey, Frederick; Rafat, Marjan; Villegas, Manuel; Praxel, A Joe; Loo, Billy W; Maxim, Peter G

    2017-01-01

    A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, "FLASH") potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Feasibility of a CdTe-based SPECT for high-resolution low-dose small animal imaging: a Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Park, S-J; Yu, A R; Lee, Y-J; Kim, Y-S; Kim, H-J

    2014-01-01

    Dedicated single-photon-emission computed tomography (SPECT) systems based on pixelated semiconductors such as cadmium telluride (CdTe) are in development to study small animal models of human disease. In an effort to develop a high-resolution, low-dose system for small animal imaging, we compared a CdTe-based SPECT system and a conventional NaI(Tl)-based SPECT system in terms of spatial resolution, sensitivity, contrast, and contrast-to-noise ratio (CNR). In addition, we investigated the radiation absorbed dose and calculated a figure of merit (FOM) for both SPECT systems. Using the conventional NaI(Tl)-based SPECT system, we achieved a spatial resolution of 1.66 mm at a 30 mm source-to-collimator distance, and a resolution of 2.4-mm hot-rods. Using the newly-developed CdTe-based SPECT system, we achieved a spatial resolution of 1.32 mm FWHM at a 30 mm source-to-collimator distance, and a resolution of 1.7-mm hot-rods. The sensitivities at a 30 mm source-to-collimator distance were 115.73 counts/sec/MBq and 83.38 counts/sec/MBq for the CdTe-based SPECT and conventional NaI(Tl)-based SPECT systems, respectively. To compare quantitative measurements in the mouse brain, we calculated the CNR for images from both systems. The CNR from the CdTe-based SPECT system was 4.41, while that from the conventional NaI(Tl)-based SPECT system was 3.11 when the injected striatal dose was 160 Bq/voxel. The CNR increased as a function of injected dose in both systems. The FOM of the CdTe-based SPECT system was superior to that of the conventional NaI(Tl)-based SPECT system, and the highest FOM was achieved with the CdTe-based SPECT at a dose of 40 Bq/voxel injected into the striatum. Thus, a CdTe-based SPECT system showed significant improvement in performance compared with a conventional system in terms of spatial resolution, sensitivity, and CNR, while reducing the radiation dose to the small animal subject. Herein, we discuss the feasibility of a CdTe-based SPECT system for high

  7. Dose effect relationships for radiation induced cancer: relevance of animal evidence

    International Nuclear Information System (INIS)

    Coggle, J.E.

    1982-01-01

    This article is based upon a paper which was presented at the SRP meeting on the Biological Bases of Radiation Protection Standards, October 1981. It is suggested that experimental radiation carcinogenesis data derived from animal studies will probably never provide numerical evidence of risk that is applicable to man. The uncertainties involved in any extrapolation of risk estimates from mice to men surely outweigh the uncertainties in the human epidemiological data. It is also suggested that at least in the foreseeable future animal data will not solve the perennial problem of the shape at low doses of the dose response curve for radiogenic cancer. At most the data may clarify the debate over linearity-non linearity and over the existence or otherwise of a threshold. However, the paper does suggest a very positive role for animal data in providing semi-quantitative generalisations for radiological protection concerning such variables as dose rate, radiation quality, partial body/organ exposure and in situations where the dose is received in a highly inhomogeneous fashion, e.g. the special problems of internal emitters. (author)

  8. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    International Nuclear Information System (INIS)

    Han, Su Chul; Park, Seung Woo

    2017-01-01

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom

  9. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Div. of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Park, Seung Woo [Radilogcial and Medico-Oncological Sciences, University of Sciences and Technology, Daejeon (Korea, Republic of)

    2017-03-15

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom.

  10. Determination of tolerance dose uncertainties and optimal design of dose response experiments with small animal numbers

    International Nuclear Information System (INIS)

    Karger, C.P.; Hartmann, G.H.

    2001-01-01

    Background: Dose response experiments aim to determine the complication probability as a function of dose. Adjusting the parameters of the frequently used dose response model P(D)=1/[1+(D 50 /D) k ] to the experimental data, 2 intuitive quantities are obtained: The tolerance dose D 50 and the slope parameter k. For mathematical reasons, however, standard statistic software uses a different set of parameters. Therefore, the resulting fit parameters of the statistic software as well as their standard errors have to be transformed to obtain D 50 and k as well as their standard errors. Material and Methods: The influence of the number of dose levels on the uncertainty of the fit parameters is studied by a simulation for a fixed number of animals. For experiments with small animal numbers, statistical artifacts may prevent the determination of the standard errors of the fit parameters. Consequences on the design of dose response experiments are investigated. Results: Explicit formulas are presented, which allow to calculate the parameters D 50 and k as well as their standard errors from the output of standard statistic software. The simulation shows, that the standard errors of the resulting parameters are independent of the number of dose levels, as long as the total number of animals involved in the experiment, remains constant. Conclusion: Statistical artifacts in experiments containing small animal numbers may be prevented by an adequate design of the experiment. For this, it is suggested to select a higher number of dose levels, rather than using a higher number of animals per dose level. (orig.) [de

  11. Consequences of the exposure at low dose rates-contribution of animal experimentation

    International Nuclear Information System (INIS)

    Masse, R.

    1990-01-01

    The exposure of laboratory animals to the various types of radiations will induce cancers in relation with the tissue absorbed doses. The shape of the dose-effet relationship is most variable. It is important to distinguish which tumours are comparable to human tumours. Those showing more analogies answer but seldom to the classical lineo-quadratic relationship; however, a strong attenuation of induction is demonstrated at low dose rates. Quasi-threshold relationships are seen after the exposure of some tissues to high-LET radiations. These observations question the validity of generalizing the radiobiologists' dual action theory, setting the origin of the dose-effect relationship in the induction of events within the DNA molecule. There is an alternative in the cellular collaboration events; it assumes that the effectiveness per dose unit decreases constantly as an inverse function of the dose rate [fr

  12. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    A method has been devised to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats, and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, some quantitative problems connected with estimating low-dose effects from other disciplines have been reviewed, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to human is discussed

  13. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    We have devised a method to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, researchers have reviewed some quantitative problems connected with estimating low-dose effects from other disciplines, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to humans is discussed

  14. Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals.

    Science.gov (United States)

    Sawall, Stefan; Bergner, Frank; Lapp, Robert; Mronz, Markus; Karolczak, Marek; Hess, Andreas; Kachelriess, Marc

    2011-03-01

    Micro-CT imaging of animal hearts typically requires a double gating procedure because scans during a breath-hold are not possible due to the long scan times and the high respiratory rates, Simultaneous respiratory and cardiac gating can either be done prospectively or retrospectively. True five-dimensional information can be either retrieved with retrospective gating or with prospective gating if several prospective gates are acquired. In any case, the amount of information available to reconstruct one volume for a given respiratory and cardiac phase is orders of magnitud lower than the total amount of information acquired. For example, the reconstruction of a volume from a 10% wide respiratory and a 20% wide cardiac window uses only 2% of the data acquired. Achieving a similar image quality as a nongated scan would therefore require to increase the amount of data and thereby the dose to the animal by up to a factor of 50. To achieve the goal of low-dose phase-correlated (LDPC) imaging, the authors propose to use a highly efficient combination of slightly modified existing algorithms. In particular, the authors developed a variant of the McKinnon-Bates image reconstruction algorithm and combined it with bilateral filtering in up to five dimensions to significantly reduce image noise without impairing spatial or temporal resolution. The preliminary results indicate that the proposed LDPC reconstruction method typically reduces image noise by a factor of up to 6 (e.g., from 170 to 30 HU), while the dose values lie in a range from 60 to 500 mGy. Compared to other publications that apply 250-1800 mGy for the same task [C. T. Badea et al., "4D micro-CT of the mouse heart," Mol. Imaging 4(2), 110-116 (2005); M. Drangova et al., "Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice," Invest. Radiol. 42(2), 85-94 (2007); S. H. Bartling et al., "Retrospective motion gating in small animal CT of mice

  15. Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

    International Nuclear Information System (INIS)

    Donnelley, Martin; Parsons, David; Morgan, Kaye; Siu, Karen

    2010-01-01

    Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 μm and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the

  16. SU-E-T-481: In Vivo and Post Mortem Animal Irradiation: Measured Vs. Calculated Doses

    Energy Technology Data Exchange (ETDEWEB)

    Heintz, P [Univ New Mexico Radiology Dept., Albuquerque, NM (United States); Heintz, B [Texas Oncology, PA, Southlake, TX (United States); Sandoval, D [University of New Mexico, Albuquerque, NM (United States); Weber, W; Melo, D; Guilmette, R [Lovelace Respiratory Research Institute, Albuquerque, NM (United States)

    2015-06-15

    Purpose: Computerized radiation therapy treatment planning is performed on almost all patients today. However it is seldom used for laboratory irradiations. The first objective is to assess whether modern radiation therapy treatment planning (RTP) systems accurately predict the subject dose by comparing in vivo and decedent dose measurements to calculated doses. The other objective is determine the importance of using a RTP system for laboratory irradiations. Methods: 5 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the absorbed dose at 5 levels (carina, lung, heart, liver and rectum) during whole body irradiation. The subjects were treated with large opposed lateral fields and extended distances to cover the entire subject using a Varian 600C linac. CT simulation was performed ante-mortem (AM) and post-mortem (PM). To compare AM and PM doses, calculation points were placed at the location of each dosimeter in the treatment plan. The measured results were compared to the results using Varian Eclipse and Prowess Panther RTP systems. Results: The Varian and Prowess treatment planning system agreed to within in +1.5% for both subjects. However there were significant differences between the measured and calculated doses. For both animals the calculated central axis dose was higher than prescribed by 3–5%. This was caused in part by inaccurate measurement of animal thickness at the time of irradiation. For one subject the doses ranged from 4% to 7% high and the other subject the doses ranged 7% to 14% high when compared to the RTP doses. Conclusions: Our results suggest that using proper CT RTP system can more accurately deliver the prescribed dose to laboratory subjects. It also shows that there is significant dose variation in such subjects when inhomogeneities are not considered in the planning process.

  17. Determination of ionizing irradiation summary dose for animals of West Kazakstan

    International Nuclear Information System (INIS)

    Gal'tsev, V.E.; Nasirov, R.N.; Gal'tseva, E.V.; Lebedev, Ya.S.; Bubnov, N.N.

    1996-01-01

    By mean of tooth enamel EPR dosimetry the accumulated radiation doses received animals near Azgyr and Tajsojgan nuclear test sites (West Kazakstan) were determined . In the work camel's two teeth (Tajsojgan) and cow's two teeth (from Azgyr and Tajsojgan test sites - accordingly) were used. Registration of EPR spectrum has been carried out on production-type EPR-spectrometer ESR-300 of Bruker firm under temperature 77 K. SHF power level is 5 MW. Constant magnetic field's modulation frequency was equal to 100 k Hz and modulation amplitude was equal to 3,2 Gs. Received data allow to make conclusion that all tested animals have got summary dose exceeded significantly a natural background radiation dose (1-1,5 μGy/y. Comparison of irradiation dose accumulated in both the front and back tooth walls testifies about predominance of hard γ-rays in the spectrum. 4 refs., 2 figs

  18. Immune reactivity after high-dose irradiation

    International Nuclear Information System (INIS)

    Gassmann, W.; Wottge, H.U.; von Kolzynski, M.; Mueller-Ruchholtz, W.

    1986-01-01

    Immune reactivity after total-body irradiation was investigated in rats using skin graft rejection as the indicator system. After sublethal irradiation with 10.5 Gy (approximately 50% lethality/6 weeks) the rejection of major histocompatibility complex allogeneic skin grafts was delayed significantly compared with nonirradiated control animals (28 versus 6.5 days). In contrast, skin grafts were rejected after 7.5 days in sublethally irradiated animals and 7 days in lethally irradiated animals if additional skin donor type alloantigens--namely, irradiated bone marrow cells--were given i.v. either simultaneously or with a delay of not more than 24 hr after the above conditioning regimen. These reactions were alloantigen-specific. They were observed in six different strain combinations with varying donors and recipients. Starting on day 2 after irradiation, i.v. injection of bone marrow gradually lost its effectivity and skin grafts were no longer rejected with uniform rapidity; skin donor marrow given on days 4 or 8 did not accelerate skin graft rejection at all. These data show that for approximately 1-2 days after high-dose total-body irradiation rats are still capable of starting a vigorous immune reaction against i.v.-injected alloantigens. The phenomenon of impaired rejection of skin grafted immediately after high-dose irradiation appears to result from the poor accessibility of skin graft alloantigens during the early postirradiation phase when vascularization of the grafted skin is insufficient

  19. Peculiarities of absorbed dose forming in some wild animals in Chornobyl exclusion zone

    Directory of Open Access Journals (Sweden)

    V. A. Gaychenko

    2015-10-01

    Full Text Available Based on field researches conducted in the exclusion zone of the Chernobyl nuclear power plant in the years after the accident, the peculiarities are identified of formation of absorbed doses in animals of different taxonomic and ecological groups that live in conditions of radioactive contamination of ecosystems. It was shown importance of consideration of radiation features on wild animals according to their life cycle, conditions and ways of life. Data were displayed about the importance of different types of irradiation according to the period of stay of the animals in the ground, in burrows and nests. The questions were reviewed about value of external and internal radiation in absorbed dose of different types of wildlife. Results of the calculation of the absorbed dose of bird embryos from egg shell were shown.

  20. The interpretation of animal data in the calculation of doses from new radiolabeled compounds

    International Nuclear Information System (INIS)

    Naylor, G.P.L.; Ellender, M.; Harrison, J.D.

    1992-01-01

    At NRPB, dose calculations are performed for pharmaceutical companies wishing to obtain approval for human volunteer experiments. Animal data from one or more species are used to estimate the radiation doses to humans that would result from the administration of novel radiolabeled compounds. The calculations themselves are straightforward, but the animal data can be interpreted in different ways, leading to variations in the calculated dose. Doses to the gut compartments usually dominate the committed effective dose equivalent, but retention in other tissues may be important for some compounds. Long-term retention components in tissues can affect doses considerably, and the binding of many radiopharmaceuticals to melanin means that doses to the eye are particularly important. The effect of these considerations on calculating doses are considered, as well as the effect of changes in risk estimates and tissue weighting factors

  1. Internal and external dose conversion coefficient for domestic reference animals and plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Park, Du Won; Choi, Young Ho

    2009-07-15

    This report presents the internal and external dose conversion coefficients for domestic reference animals and plant, which are essential to assess the radiological impact of an environmental radiation on non-human species. To calculate the dose conversion coefficients, a uniform isotropic model and a Monte Carlo method for a photon transport simulation in environmental media with different densities have been applied for aquatic and terrestrial animals, respectively. In the modeling all the target animals are defined as a simple 3D elliptical shape. To specify the external radiation source it is assumed that aquatic animals are fully immersed in infinite and uniformly contaminated water, and the on-soil animals are living on the surface of a horizontally infinite soil source, and the in-soil organisms are living at the center of a horizontally infinite and uniformly contaminated soil to a depth of 50cm. A set of internal and external dose conversion coefficients for 8 Korean reference animals and plant (rat, roe-deer, frog, snake, Chinese minnow, bee, earthworm, and pine tree) are presented for 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, {sup 95}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, and {sup 240}Pu)

  2. A new tissue segmentation method to calculate 3D dose in small animal radiation therapy.

    Science.gov (United States)

    Noblet, C; Delpon, G; Supiot, S; Potiron, V; Paris, F; Chiavassa, S

    2018-02-26

    In pre-clinical animal experiments, radiation delivery is usually delivered with kV photon beams, in contrast to the MV beams used in clinical irradiation, because of the small size of the animals. At this medium energy range, however, the contribution of the photoelectric effect to absorbed dose is significant. Accurate dose calculation therefore requires a more detailed tissue definition because both density (ρ) and elemental composition (Z eff ) affect the dose distribution. Moreover, when applied to cone beam CT (CBCT) acquisitions, the stoichiometric calibration of HU becomes inefficient as it is designed for highly collimated fan beam CT acquisitions. In this study, we propose an automatic tissue segmentation method of CBCT imaging that assigns both density (ρ) and elemental composition (Z eff ) in small animal dose calculation. The method is based on the relationship found between CBCT number and ρ*Z eff product computed from known materials. Monte Carlo calculations were performed to evaluate the impact of ρZ eff variation on the absorbed dose in tissues. These results led to the creation of a tissue database composed of artificial tissues interpolated from tissue values published by the ICRU. The ρZ eff method was validated by measuring transmitted doses through tissue substitute cylinders and a mouse with EBT3 film. Measurements were compared to the results of the Monte Carlo calculations. The study of the impact of ρZ eff variation over the range of materials, from ρZ eff  = 2 g.cm - 3 (lung) to 27 g.cm - 3 (cortical bone) led to the creation of 125 artificial tissues. For tissue substitute cylinders, the use of ρZ eff method led to maximal and average relative differences between the Monte Carlo results and the EBT3 measurements of 3.6% and 1.6%. Equivalent comparison for the mouse gave maximal and average relative differences of 4.4% and 1.2%, inside the 80% isodose area. Gamma analysis led to a 94.9% success rate in the 10% isodose

  3. Peculiarities of absorbed dose forming in some wild animals in Chornobyl,y exclusion zone

    International Nuclear Information System (INIS)

    Gaychenko, V.A.; Krainiuk, O.Yu.

    2015-01-01

    Based on field researches conducted in the exclusion zone of the Chernobyl nuclear power plant in the years after the accident, identified the peculiarities of formation absorbed doses in animals of different taxonomic and ecological groups that live in conditions of radioactive contamination of ecosystems. Was shown importance of consideration of radiation features on wild animals according to their life cycle, conditions and ways of life. Was displayed data about the importance of different types of irradiation according to the period of stay the animals in the ground, in burrows and nests. Was reviewed the questions about value of external and internal radiation in absorbed dose of different types of wildlife. Was shown the results of the calculation of the absorbed dose of bird embryos from egg shell

  4. Internal Dose Conversion Coefficients of Domestic Reference Animal and Plants for Dose Assessment of Non-human Species

    International Nuclear Information System (INIS)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho

    2009-01-01

    Traditionally, radiation protection has been focused on a radiation exposure of human beings. In the international radiation protection community, one of the recent key issues is to establish the methodology for assessing the radiological impact of an ionizing radiation on non-human species for an environmental protection. To assess the radiological impact to non-human species dose conversion coefficients are essential. This paper describes the methodology to calculate the internal dose conversion coefficient for non-human species and presents calculated internal dose conversion coefficients of 25 radionuclides for 8 domestic reference animal and plants

  5. High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography

    Science.gov (United States)

    Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.

    2016-12-01

    X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.

  6. Variable effects of high-dose adrenaline relative to standard-dose adrenaline on resuscitation outcomes according to cardiac arrest duration.

    Science.gov (United States)

    Jeung, Kyung Woon; Ryu, Hyun Ho; Song, Kyung Hwan; Lee, Byung Kook; Lee, Hyoung Youn; Heo, Tag; Min, Yong Il

    2011-07-01

    Adjustment of adrenaline (epinephrine) dosage according to cardiac arrest (CA) duration, rather than administering the same dose, may theoretically improve resuscitation outcomes. We evaluated variable effects of high-dose adrenaline (HDA) relative to standard-dose adrenaline (SDA) on resuscitation outcomes according to CA duration. Twenty-eight male domestic pigs were randomised to the following 4 groups according to the dosage of adrenaline (SDA 0.02 mg/kg vs. HDA 0.2mg/kg) and duration of CA before beginning cardiopulmonary resuscitation (CPR): 6 min SDA, 6 min HDA, 13 min SDA, or 13 min HDA. After the predetermined duration of untreated ventricular fibrillation, CPR was provided. All animals in the 6 min SDA, 6 min HDA, and 13 min HDA groups were successfully resuscitated, while only 4 of 7 pigs in the 13 min SDA group were successfully resuscitated (p=0.043). HDA groups showed higher right atrial pressure, more frequent ventricular ectopic beats, higher blood glucose, higher troponin-I, and more severe metabolic acidosis than SDA groups. Animals of 13 min groups showed more severe metabolic acidosis and higher troponin-I than animals of 6 min groups. All successfully resuscitated animals, except two animals in the 13 min HDA group, survived for 7 days (p=0.121). Neurologic deficit score was not affected by the dose of adrenaline. HDA showed benefit in achieving restoration of spontaneous circulation in 13 min CA, when compared with 6 min CA. However, this benefit did not translate into improved long-term survival or neurologic outcome. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Biological impact of high-dose and dose-rate radiation exposure

    International Nuclear Information System (INIS)

    Maliev, V.; Popov, D.; Jones, J.; Gonda, S.; Prasad, K.; Viliam, C.; Haase, G.; Kirchin, V.; Rachael, C.

    2006-01-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  8. Biological impact of high-dose and dose-rate radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Maliev, V.; Popov, D. [Russian Academy of Science, Vladicaucas (Russian Federation); Jones, J.; Gonda, S. [NASA -Johnson Space Center, Houston (United States); Prasad, K.; Viliam, C.; Haase, G. [Antioxida nt Research Institute, Premier Micronutrient Corporation, Novato (United States); Kirchin, V. [Moscow State Veterinary and Biotechnology Acade my, Moscow (Russian Federation); Rachael, C. [University Space Research Association, Colorado (United States)

    2006-07-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  9. Measurement and research of the exposure doses of the animal guardians and radiation workers in the animal hospital in Gwangju

    International Nuclear Information System (INIS)

    Kang, Ji Seung; Yun, Seon Yeong; Yeo, Hwa Yeon; Dong, Kyung Rae

    2016-01-01

    In modern society, having companion animals as family members is getting popular. According to the data from National Statistical Office, the population of people with companion animals and pets is now over 10 million. The increase of companion animals led to an increase of animal hospitals. Accordingly, radiation generating devices for diagnosis are being used frequently. In addition, as animal hospitals are increasingly using radiation generating devices, in order to protect the related workers and promote animal cares, the government enacted the regulations relating to operations and installations of the devices at animal hospitals. Therefore, this study handles the radiation safety management related stuffs by measuring and assessing radiation dose to the animal guardians and radiation workers in the animal hospitals in Gwangju

  10. Measurement and research of the exposure doses of the animal guardians and radiation workers in the animal hospital in Gwangju

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ji Seung; Yun, Seon Yeong; Yeo, Hwa Yeon [Dept. of Radiology, Nambu University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Dept. of of Radiological Technology, Gwangju Health University, Kwangju (Korea, Republic of)

    2016-11-15

    In modern society, having companion animals as family members is getting popular. According to the data from National Statistical Office, the population of people with companion animals and pets is now over 10 million. The increase of companion animals led to an increase of animal hospitals. Accordingly, radiation generating devices for diagnosis are being used frequently. In addition, as animal hospitals are increasingly using radiation generating devices, in order to protect the related workers and promote animal cares, the government enacted the regulations relating to operations and installations of the devices at animal hospitals. Therefore, this study handles the radiation safety management related stuffs by measuring and assessing radiation dose to the animal guardians and radiation workers in the animal hospitals in Gwangju.

  11. High dose lansoprazole combined with metronomic chemotherapy: a phase I/II study in companion animals with spontaneously occurring tumors.

    Science.gov (United States)

    Spugnini, Enrico P; Buglioni, Sabrina; Carocci, Francesca; Francesco, Menicagli; Vincenzi, Bruno; Fanciulli, Maurizio; Fais, Stefano

    2014-08-21

    The treatment of human cancer has been seriously hampered for decades by resistance to chemotherapeutic drugs. A very efficient mechanism of tumor resistance to drugs is the proton pumps-mediated acidification of tumor microenvironment. Metronomic chemotherapy has shown efficacy in adjuvant fashion as well as in the treatment of pets with advanced disease. Moreover, we have shown in veterinary clinical settings that pre-treatment with proton-pumps inhibitors (PPI) increases tumor responsiveness to chemotherapeutics. In this study pet with spontaneously occurring cancer have been recruited to be treated by a combination of metronomic chemotherapy and high dose PPIs and their responses have been matched to those of a historical control of ten patients treated with metronomic chemotherapy alone. Single arm, non randomized phase II open study, with historical control group, evaluating safety and efficacy of the combination of metronomic chemotherapy and alkalization. Twenty-four companion animals (22 dogs and 2 cats) were treated adding to their metronomic chemotherapy protocol the pump inhibitor lansoprazole at high dose, and a water alkalizer. Their responses have been evaluated by clinical and instrumental evaluation and matched to those of the control group. The protocol was overall well tolerated, with only two dogs experiencing side effects due to gastric hypochlorhydria consisting with vomiting and or diarrhea. In terms of overall response, in the alkalized cohort, 18 out of 24 had partial or complete responses (75%), two patients had a stable disease and the remaining patients experienced no response or progressive disease. On the other hand, only one patient in the control group experienced a complete response (10%) and three other experienced short lived responses. Median time to terminal event was 34 weeks for the experimental group versus 2 weeks in the controls (p= 0.042). Patient alkalization has shown to be well tolerated and to increase tumor response

  12. Interpretation of animal data in the calculation of doses from new radiolabelled compounds

    International Nuclear Information System (INIS)

    Ellender, M.; Naylor, G.P.L.

    1992-01-01

    The Radionuclide Biokinetics Group of the Biomedical Effects Department at NRPB provides a dose calculation service for pharmaceutical companies and associated laboratories which plan to administer radiolabelled drugs to human volunteers as part of their research and development programmes for new compounds. Animal data provided by these companies are used to estimate the likely doses to humans from administration of the compound. The dose estimate then accompanies the pharmaceutical company's application for approval from the UK Administration of Radioactive Substances Advisory Committee (ARSAC). The method of calculation, the interpretation of the animal data and the range of results obtained are discussed. In addition, the effect of the use of the new ICRP tissue weighting factors in the calculations is considered. (Author)

  13. Dose imprecision and resistance: free-choice medicated feeds in industrial food animal production in the United States.

    Science.gov (United States)

    Love, David C; Davis, Meghan F; Bassett, Anna; Gunther, Andrew; Nachman, Keeve E

    2011-03-01

    Industrial food animal production employs many of the same antibiotics or classes of antibiotics that are used in human medicine. These drugs can be administered to food animals in the form of free-choice medicated feeds (FCMF), where animals choose how much feed to consume. Routine administration of these drugs to livestock selects for microorganisms that are resistant to medications critical to the treatment of clinical infections in humans. In this commentary, we discuss the history of medicated feeds, the nature of FCMF use with regard to dose delivery, and U.S. policies that address antimicrobial drug use in food animals. FCMF makes delivering a predictable, accurate, and intended dose difficult. Overdosing can lead to animal toxicity; underdosing or inconsistent dosing can result in a failure to resolve animal diseases and in the development of antimicrobial-resistant microorganisms. The delivery of antibiotics to food animals for reasons other than the treatment of clinically diagnosed disease, especially via free-choice feeding methods, should be reconsidered.

  14. Low-dose computed tomography to detect body-packing in an animal model

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H., E-mail: martin.maurer@charite.de [Klinik fuer Strahlenheilkunde, Charite - Universitaetsmedizin, Berlin (Germany); Niehues, S.M.; Schnapauff, D.; Grieser, C.; Rothe, J.H. [Klinik fuer Strahlenheilkunde, Charite - Universitaetsmedizin, Berlin (Germany); Waldmueller, D. [Bildungs- und Wissenschaftszentrum der Bundesfinanzverwaltung, Berlin (Germany); Chopra, S.S. [Klinik fuer Allgemein-, Viszeral- und Transplantationschirurgie, Charite - Universitaetsmedizin, Berlin (Germany); Hamm, B.; Denecke, T. [Klinik fuer Strahlenheilkunde, Charite - Universitaetsmedizin, Berlin (Germany)

    2011-05-15

    Objective: To assess the possible extent of dose reduction for low-dose computed tomography (CT) in the detection of body-packing (ingested drug packets) as an alternative to plain radiographs in an animal model. Materials and methods: Twelve packets containing cocaine (purity >80%) were introduced into the intestine of an experimental animal (crossbred pig), which was then repeatedly examined by abdominal CT with stepwise dose reduction (tube voltage, 80 kV; tube current, 10-350 mA). Three blinded readers independently evaluated the CT datasets starting with the lowest tube current and noted the numbers of packets detected at the different tube currents used. In addition, 1 experienced reader determined the number of packets detectable on plain abdominal radiographs and ultrasound. Results: The threshold for correct identification of all 12 drug packets was 100 mA for reader 1 and 125 mA for readers 2 and 3. Above these thresholds all 3 readers consistently identified all 12 packets. The effective dose of a low-dose CT scan with 125 mA (including scout view) was 1.0 mSv, which was below that of 2 conventional abdominal radiographs (1.2 mSv). The reader interpreting the conventional radiographs identified a total of 9 drug packets and detected 8 packets by abdominal ultrasound. Conclusions: Extensive dose reduction makes low-dose CT a valuable alternative imaging modality for the examination of suspected body-packers and might replace conventional abdominal radiographs as the first-line imaging modality.

  15. Evaluation of experimental animal biological state at exposure to low-dose ionizing radiation

    International Nuclear Information System (INIS)

    Rozanov, V.A.; Rejtarova, T.Je.; Chernyikov, G.B.; Timoshevs'ka, Je.V.; Kozozojeva, O.O.

    1997-01-01

    New approaches to quantitative evaluation of ionizing radiation absorbed dose within the low-dose range (up to 400 mGy) according to the degree of the organism biological response was developed. The purpose of the stage of the work published in Communication 1 is to evaluate the shifts in the animal behaviour and cellular composition of the blood at irradiation by the dose of 100,200 and 400 mGy. Distinct dose dependence of behaviour reactions and hematological indices within the dose range of 100-400 mGy was not noted

  16. Assessment of diurnal systemic dose of agrochemicals in regulatory toxicity testing--an integrated approach without additional animal use.

    Science.gov (United States)

    Saghir, Shakil A; Bartels, Michael J; Rick, David L; McCoy, Alene T; Rasoulpour, Reza J; Ellis-Hutchings, Robert G; Sue Marty, M; Terry, Claire; Bailey, Jason P; Billington, Richard; Bus, James S

    2012-07-01

    Integrated toxicokinetics (TK) data provide information on the rate, extent and duration of systemic exposure across doses, species, strains, gender, and life stages within a toxicology program. While routine for pharmaceuticals, TK assessments of non-pharmaceuticals are still relatively rare, and have never before been included in a full range of guideline studies for a new agrochemical. In order to better understand the relationship between diurnal systemic dose (AUC(24h)) and toxicity of agrochemicals, TK analyses in the study animals is now included in all short- (excluding acute), medium- and long-term guideline mammalian toxicity studies including reproduction/developmental tests. This paper describes a detailed procedure for the implementation of TK in short-, medium- and long-term regulatory toxicity studies, without the use of satellite animals, conducted on three agrochemicals (X11422208, 2,4-D and X574175). In these studies, kinetically-derived maximum doses (KMD) from short-term studies instead of, or along with, maximum tolerated doses (MTD) were used for the selection of the high dose in subsequent longer-term studies. In addition to leveraging TK data to guide dose level selection, the integrated program was also used to select the most appropriate method of oral administration (i.e., gavage versus dietary) of test materials for rat and rabbit developmental toxicity studies. The integrated TK data obtained across toxicity studies (without the use of additional/satellite animals) provided data critical to understanding differences in response across doses, species, strains, sexes, and life stages. Such data should also be useful in mode of action studies and to improve human risk assessments. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Contribution of inhalation by food animals to man's ingestion dose

    International Nuclear Information System (INIS)

    Zach, R.

    1985-01-01

    Animals' inhalation (AI) pathway was evaluated for 57 radionuclides using infant dose predictions from the food-chain model LIMCAL. With ingestion transfer coefficients fMi to define transfer from the respiratory tract to milk, the AI pathway appeared to be insignificant compared to animals' plant ingestion, as implicitly assumed in most environmental assessment models for nuclear installations. Using ICRP Publication 30 respiratory clearance models for man to adjust ingestion transfer coefficients, animals' inhalation appeared to be important, particularly for some actinide radionuclides. The AI pathway also appeared to be significant relative to man's inhalation, especially for infants. The importance of the AI pathway varied greatly between radionuclides, and results strongly suggest that it cannot be ignored in environmental assessments. Until better data become available to implement this pathway fully, adjusted ingestion transfer coefficient values can be used for transfer from animals' respiratory tract to milk and other food products

  18. High Dose MicroCT Does Not Contribute Toward Improved MicroPET/CT Image Quantitative Accuracy and Can Limit Longitudinal Scanning of Small Animals

    Directory of Open Access Journals (Sweden)

    Wendy A. McDougald

    2017-10-01

    Full Text Available Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1 to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2 to evaluate the absorbed dose associated with varying CT parameters.Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA software implemented by Mediso. Measured Hounsfield Unit (HU in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC, uniformity and quantitative bias were also measured.Results: Only less than 2 and 1% of CT acquisition protocols yielded water HU values < −80 and air HU values < −840, respectively. Four out of 11 CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration.Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed toward improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.

  19. Influence of radioprotectors on total body weight evolution and on oxygen consumption in lethal dose irradiated animals. (Preliminary study)

    International Nuclear Information System (INIS)

    Fatome, M.; Martine, G.; Bargy, E.; Andrieu, L.

    Comparison of total body weight evolution and oxygen consumption in lethal dose irradiated animals, protected by various well known radioprotective substances, isolated or in mixture, with evolution and consumption of non protected animals irradiated at the same dose and with these of check animals [fr

  20. Dose and effect relationship of radiation induced cancer and its influencing factors in experimental animals, 1

    International Nuclear Information System (INIS)

    Sasaki, Shunsaku; Sato, Fumiaki; Eto, Hideo

    1975-01-01

    The data of risk evaluation of external irradiation were integrated with animal experiments from the aspects of qualitative generalizations of characteristics of radiation induced tumors. Studies covered competition of cause of death, figure of dose-to-effect relationship, characteristics of low dose rate of irradiation, relative biological effectiveness (RBE) of high LET radiation, effects of feactionated irradiation, complex actions with chemical substances, effects of protectional medium, differences of radiosensitivity by species and strains, and age dependency of sensitivities. Competition of cause of death by time length of latent period and degree of malignancy of the disease. Discussion on competition of death suggested the following idea: 1) incidence of tumor induction in the individual level did not correspond to transformation in the cellular level, and 2) relative incidence of tumor induction after a certain dose of whole body irradiation did not indicate the relative sensitivity of each tissue, for the relationship between tumor incidence and exposure dose was not a linear relationship. The dose-to-effect relationship of tumor induction was decided by following factors: i) sensitivity on transformation of cells, ii) sensitivity on the death of potential tumor cells, and iii) competition of the cause of death. Tumor induction by low dose rate irradiation was also studied by comparing qualitative and quantitative differences between high dose rate single irradiation and a series of low dose rate irradiation. (Serizawa, K.)

  1. COMPARING BEHAVIORAL DOSE-EFFECT CURVES FOR HUMANS AND LABORATORY ANIMALS ACUTELY EXPOSED TO TOLUENE.

    Science.gov (United States)

    The utility of laboratory animal data in toxicology depends upon the ability to generalize the results quantitatively to humans. To compare the acute behavioral effects of inhaled toluene in humans to those in animals, dose-effect curves were fitted by meta-analysis of published...

  2. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    International Nuclear Information System (INIS)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L.; Filho, A. M.

    2014-08-01

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  3. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L. [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Filho, A. M., E-mail: venezianigr@gmail.com [Centro Universitario de Rio Petro - UNIRP, Rodovia Br 153 (Transbrasiliana), Km. 69 Sao Jose do Rio Preto, Sao Paulo (Brazil)

    2014-08-15

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  4. Consequences of the exposure at low dose rates-contribution of animal experimentation. Consequences de l'exposition aux faibles debits de dose. Apport de l'experimentation animale

    Energy Technology Data Exchange (ETDEWEB)

    Masse, R. (CEA Centre d' Etudes de Fontenay-aux-Roses, 92 (FR). Direction des Sciences du Vivant)

    1990-01-01

    The exposure of laboratory animals to the various types of radiations will induce cancers in relation with the tissue absorbed doses. The shape of the dose-effet relationship is most variable. It is important to distinguish which tumours are comparable to human tumours. Those showing more analogies answer but seldom to the classical lineo-quadratic relationship; however, a strong attenuation of induction is demonstrated at low dose rates. Quasi-threshold relationships are seen after the exposure of some tissues to high-LET radiations. These observations question the validity of generalizing the radiobiologists' dual action theory, setting the origin of the dose-effect relationship in the induction of events within the DNA molecule. There is an alternative in the cellular collaboration events; it assumes that the effectiveness per dose unit decreases constantly as an inverse function of the dose rate.

  5. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  6. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    International Nuclear Information System (INIS)

    Cantinha, Rebeca S.; Nakano, Eliana; Silva, Luanna R.S.

    2009-01-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of 60 Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD 50 obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  7. The paradox of human equivalent dose formula: A canonical case study of abrus precatorius aqueous leaf extract in monogastric animals

    Directory of Open Access Journals (Sweden)

    Saganuwan Alhaji Saganuwan

    2016-03-01

    Full Text Available There is abundant literature on the toxicity of A. precatorius seeds. However there is a need to define the toxicity limit of the Abrus precatorius leaf in monogastric animals. Human Equivalent Dose (HED which is equal to animal dose multiplied by animal km (metabolism constant divided by human km was used to project the LD50 of fifteen monogastric animals , where human km factor is body weight (kg divided by body surface area (m2. Human Equivalent No-observable Adverse Effect Doses were determined by multiplying the animal no-observable adverse effect dose by animal weight (Wa divided by human weight (Wh. The LD50 of the aqueous leaf extract of Abrus precatorius in mice was estimated to be between 2559.5 and 3123.3 mg/kg body weight. The LD50 extrapolated from mouse to rat (1349.3-1646.6 mg/kg, hamster (1855.3-2264.1 mg/kg, guinea pig (1279.5-1561.4 mg/kg, rabbit (618.4-754.7 mg/kg, monkey (593.7-724.5 mg/kg, cat (392.7-479.2 mg/kg, dog and baboon (371.1-452.8 mg/kg, child (297-362 mg/kg and adult human (197.8-241.5 mg/kg body weight respectively could be a reality. The therapeutic safe dose range for the animals was 1-12.5 mg/kg body weight for a period of 7 days, but at a dose (≤ 200 mg/kg body weight the leaf extract showed haematinic effect. However, at a higher dose (> 200 mg/kg, the extract showed haemolytic activity in rats, whereas at a dose (≥25.0 mg/kg, the leaf extract might be organotoxic in hamster, guinea pig, rabbit, monkey, cat, dog, baboon, child and adult human if administered orally for a period of 7 days.

  8. A method for comparison of animal and human alveolar dose and toxic effect of inhaled ozone

    International Nuclear Information System (INIS)

    Hatch, G.E.; Koren, H.; Aissa, M.

    1989-01-01

    Present models for predicting the pulmonary toxicity of O 3 in humans from the toxic effects observed in animals rely on dosimetric measurements of O 3 mass balance and species comparisons of mechanisms that protect tissue against O 3 . The goal of the study described was to identify a method to directly compare O 3 dose and effect in animals and humans using bronchoalveolar lavage fluid markers. The feasibility of estimating O 3 dose to alveoli of animals and humans was demonstrated through assay of reaction products of 18 O-labeled O 3 in lung surfactant and macrophage pellets of rabbits. The feasibility of using lung lavage fluid protein measurements to quantify the O 3 toxic response in humans was demonstrated by the finding of significantly increased lung lavage protein in 10 subjects exposed to 0.4 ppm O 3 for 2 h with intermittent periods of heavy exercise. The validity of using the lavage protein marker to quantify the response in animals has already been established. The positive results obtained in both the 18 O 3 and the lavage protein studies reported here suggest that it should be possible to obtain a direct comparison of both alveolar dose and toxic effect of O 3 to alveoli of animals or humans

  9. MOSFET assessment of radiation dose delivered to mice using the Small Animal Radiation Research Platform (SARRP).

    Science.gov (United States)

    Ngwa, Wilfred; Korideck, Houari; Chin, Lee M; Makrigiorgos, G Mike; Berbeco, Ross I

    2011-12-01

    The Small Animal Radiation Research Platform (SARRP) is a novel isocentric irradiation system that enables state-of-the-art image-guided radiotherapy research to be performed with animal models. This paper reports the results obtained from investigations assessing the radiation dose delivered by the SARRP to different anatomical target volumes in mice. Surgically implanted metal oxide semiconductor field effect transistors (MOSFET) dosimeters were employed for the dose assessment. The results reveal differences between the calculated and measured dose of -3.5 to 0.5%, -5.2 to -0.7%, -3.9 to 0.5%, -5.9 to 2.5%, -5.5 to 0.5%, and -4.3 to 0% for the left kidney, liver, pancreas, prostate, left lung, and brain, respectively. Overall, the findings show less than 6% difference between the delivered and calculated dose, without tissue heterogeneity corrections. These results provide a useful assessment of the need for tissue heterogeneity corrections in SARRP dose calculations for clinically relevant tumor model sites.

  10. A long-acting integrase inhibitor protects female macaques from repeated high-dose intravaginal SHIV challenge.

    Science.gov (United States)

    Andrews, Chasity D; Yueh, Yun Lan; Spreen, William R; St Bernard, Leslie; Boente-Carrera, Mar; Rodriguez, Kristina; Gettie, Agegnehu; Russell-Lodrigue, Kasi; Blanchard, James; Ford, Susan; Mohri, Hiroshi; Cheng-Mayer, Cecilia; Hong, Zhi; Ho, David D; Markowitz, Martin

    2015-01-14

    Long-acting GSK1265744 (GSK744 LA) is a strand transfer inhibitor of the HIV/SIV (simian immunodeficiency virus) integrase and was shown to be an effective preexposure prophylaxis (PrEP) agent in a low-dose intrarectal SHIV (simian-human immunodeficiency virus) rhesus macaque challenge model. We examined the pharmacokinetics and efficacy of GSK744 LA as PrEP against repeat high-dose intravaginal SHIV challenge in female rhesus macaques treated with Depo-Provera (depot medroxyprogesterone acetate), which promotes viral transmission vaginally. When Depo-Provera-treated female rhesus macaques were dosed with GSK744 LA (50 mg/kg) monthly, systemic and tissue drug concentrations were lower than previously observed in male rhesus macaques. GSK744 concentrations were fivefold lower on average in cervical tissues than in rectal tissues. Eight female rhesus macaques were treated with GSK744 LA at week 0, and four female rhesus macaques served as controls. All animals received a high-dose challenge of SHIV162P3 at week 1. No infection was detected in GSK744 LA-treated rhesus macaques, whereas viremia was detected 1 to 2 weeks after SHIV challenge in all control animals. The GSK744 LA-treated rhesus macaques were given a second administration of drug at week 4 and further challenged at weeks 5 and 7. GSK744 LA treatment protected six of eight female rhesus macaques against three high-dose SHIV challenges, whereas all control animals became infected after the first challenge (P = 0.0003, log-rank test). These results support further clinical development of GSK744 LA for PrEP. Copyright © 2015, American Association for the Advancement of Science.

  11. Evaluating the Effect of Electron-Beam Irradiation on Linguatula serrata Destroy Isolated from Animal Products and Determining its Effective Dose

    Directory of Open Access Journals (Sweden)

    S Khalatbari-limaki

    2015-11-01

    Full Text Available Abstract Introduction: Foodborne parasitic diseases are considered common in most parts of the world, which can cause significant health problems. Linguatula serrata is a zoonotic parasite causing human linguatulosis due to consumption of raw and semi-cooked animal offal infected with nymphs of this parasite. Therefore, the main objective of this study was to determine the effect of Electron beam irradiation on death of the Linguatula serrata nymphs isolated from animal products. Methods: Linguatula serrata nymphs were irradiated with E-beam irradiation of 1, 2, 3 and 5 kGy doses 15 nymphs were classified into three groups of 5 for each dose. Death time of the nymphs was recorded by examining their movement under a stereomicroscope and then was compared with that of the control group stored at 4 °C. In order to analyze the study data, T-test and ANOVA were utilized setting the significance level at 0.05. Results: The comparison between treatment and control groups demonstrated a statistically significant difference in death time of the nymphs (P 0.05. Moreover, there was a statistically significant difference between the doses of 1, 2 and 3 kGy with dose of 5 kGy (P 0.05 in regard with their lethality speed. The results showed that minimum destruction dose of Linguatula serrata nymphs was 1 kGy and 5 KGy , resulted in a more rapidly death within the nymphs. Conclusion: Regarding the high sensitivity of Linguatula serrata nymphs to E-beam irradiation, this method can be used to enhance the safety of animal products in future.

  12. Conditioned instrumental behaviour in the rat: Effects of prenatal irradiation with various low dose-rate doses

    International Nuclear Information System (INIS)

    Klug, H.

    1986-01-01

    4 groups of rats of the Wistar-strain were subjected to γ-irradiation on the 16th day of gestation. 5 rats received 0,6 Gy low dose rate irradiation, 5 animals received 0,9 Gy low dose and 6 high dose irradiation, 3 females were shamirradiated. The male offspring of these 3 irradiation groups and 1 control group were tested for locomotor coordination on parallel bars and in a water maze. The female offspring were used in an operant conditioning test. The locomotor test showed slight impairment of locomotor coordination in those animals irradiated with 0,9 Gy high dose rate. Swimming ability was significantly impaired by irradiation with 0,9 Gy high dose rate. Performance in the operant conditioning task was improved by irradiation with 0,9 Gy both low and high dose rate. The 0,9 Gy high dose rate group learned faster than all the other groups. For the dose of 0,9 Gy a significant dose rate effect could be observed. For the dose of 0,6 Gy a similar tendency was observed, differences between 0,6 Gy high and low dose rate and controls not being significant. (orig./MG) [de

  13. A blinded, randomized, controlled trial of three doses of high-dose insulin in poison-induced cardiogenic shock.

    Science.gov (United States)

    Cole, J B; Stellpflug, S J; Ellsworth, H; Anderson, C P; Adams, A B; Engebretsen, K M; Holger, J S

    2013-05-01

    High dose insulin (HDI) has proven superior to glucagon and catecholamines in the treatment of poison-induced cardiogenic shock (PICS) in previous animal studies. Standard recommendations for dosing of insulin vary and the optimal dose of HDI in PICS has not been established. Our hypothesis was a dose of 10 U/kg/hr of HDI would be superior to 1 U/kg/hr with cardiac output (CO) as our primary outcome measure in pigs with propranolol-induced PICS. This was a blinded, prospective, randomized trial with 4 arms consisting of 4 pigs in each arm. The arms were as follows: placebo (P), 1 U/kg/hr (HDI-1), 5 U/kg/hr (HDI-5), and 10 U/kg/hr (HDI-10). Cardiogenic shock was induced with a bolus of 0.5 mg/kg of propranolol followed by an infusion of 0.25 mg/kg/min until the point of toxicity, defined as 0.75 x (HR x MAP) was reached. At this point the propranolol infusion was decreased to 0.125 mg/kg/min and a 20 mL/kg bolus of normal saline (NS) was administered. The protocol was continued for 6 hours or until the animals died. 2 pigs died in the P arm, 1 pig died each in the HDI-1 and HDI-5 arms, and all pigs lived in the HDI-10 arm. There was a statistically significant difference in dose by time interaction on CO of 1.13 L/min over the 6 hr study period (p = < 0.001). There was also a statistically significant difference in dose by time interaction on MAP, HR, and systemic vascular resistance (SVR). No statistically significant difference was found between any of the arms regarding glucose utilization. HDI was statistically and clinically significantly superior to placebo in this propranolol model of PICS. Furthermore a dose response over time was found where CO increased corresponding to increases in doses of HDI.

  14. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  15. External dose estimation of the human associated with companion animals under veterinary nuclear medical diagnosis

    International Nuclear Information System (INIS)

    Ito, Nobuhiko; Hanawa, Asumi; Suzuki, Kanan

    2004-01-01

    This study was performed in order to make a safety guideline for veterinary nuclear medicine in Japan. Well often used radionuclides ( 18 F and 99 mTc) were employed for evaluating the external radiation exposures of veterinarians, animal owners, and the public. The human external radiation exposure from radiation sources in phantom likened to animal was considered by comparing the results of computer simulation and the actually measured exposure. The computer simulation was performed by using macro program of Microsoft Visual Basic for Applications (VBA). In this simulation calculation process, radiation absorption and buildup were taken into consideration with the gamma ray emitted from radioactive materials in the body of the animal. Both corresponded well though the simulation result tended to be overvalued from the actual measurement value. Therefore, it is thought that this system can be applied to the estimation of human's external exposure. When the calculation was done on the condition that the radioactive substance exists only in internal organs (heart, liver, kidneys, and bladder), the unequal distribution of the dose rate was found near the animal body. External radiation exposure estimation to the veterinarian, the animal owner and the public was performed under consideration of the actual working condition, the distance from the source, and the time of exposure. In the calculation, the radiation dose of the animal owner and the public did not exceed the dose limit (5 mSv/yr for the animal owner, and 1 mSv/yr for the general public: International Commission of Radiological Protection (ICRP) 1990) in the release after 24 hours of the radiopharmaceutical administering. The calculation condition used in this study was actually more excessive. So the authors consider these exposures would cause no significant issue by starting the veterinary nuclear medicine in Japan. Moreover, since injected radiopharmaceutical is excreted out of the body actually, the

  16. Principles of animal extrapolation

    Energy Technology Data Exchange (ETDEWEB)

    Calabrese, E.J.

    1991-01-01

    Animal Extrapolation presents a comprehensive examination of the scientific issues involved in extrapolating results of animal experiments to human response. This text attempts to present a comprehensive synthesis and analysis of the host of biomedical and toxicological studies of interspecies extrapolation. Calabrese's work presents not only the conceptual basis of interspecies extrapolation, but also illustrates how these principles may be better used in selection of animal experimentation models and in the interpretation of animal experimental results. The book's theme centers around four types of extrapolation: (1) from average animal model to the average human; (2) from small animals to large ones; (3) from high-risk animal to the high risk human; and (4) from high doses of exposure to lower, more realistic, doses. Calabrese attacks the issues of interspecies extrapolation by dealing individually with the factors which contribute to interspecies variability: differences in absorption, intestinal flora, tissue distribution, metabolism, repair mechanisms, and excretion. From this foundation, Calabrese then discusses the heterogeneticity of these same factors in the human population in an attempt to evaluate the representativeness of various animal models in light of interindividual variations. In addition to discussing the question of suitable animal models for specific high-risk groups and specific toxicological endpoints, the author also examines extrapolation questions related to the use of short-term tests to predict long-term human carcinogenicity and birth defects. The book is comprehensive in scope and specific in detail; for those environmental health professions seeking to understand the toxicological models which underlay health risk assessments, Animal Extrapolation is a valuable information source.

  17. Animal data on GI-tract uptake of plutonium - implications for environmental dose assessments

    International Nuclear Information System (INIS)

    Kocher, D.C.; Ryan, M.T.

    1983-01-01

    A selection of published data on GI-tract uptake of ingested plutonium in animals is reviewed for the purpose of estimating an uptake fraction which would be appropriate for environmental dose assessments in adult humans. Recent data in the adult rat and guinea pig suggest that a GI-tract uptake fraction of 10 -3 would be a reasonable and prudent choice for ingestion of environmental plutonium by adults. This value is a factor of ten larger than the value currently recommended by the International Commission on Radiological Protection for assessing doses from occupational exposures. (author)

  18. Evaluation of low dose ionizing radiation effect on some blood components in animal model

    OpenAIRE

    El-Shanshoury, H.; El-Shanshoury, G.; Abaza, A.

    2016-01-01

    Exposure to ionizing radiation is known to have lethal effects in blood cells. It is predicted that an individual may spend days, weeks or even months in a radiation field without becoming alarmed. The study aimed to discuss the evaluation of low dose ionizing radiation (IR) effect on some blood components in animal model. Hematological parameters were determined for 110 animal rats (divided into 8 groups) pre- and post-irradiation. An attempt to explain the blood changes resulting from both ...

  19. High-dose vitamin C and cancer

    Directory of Open Access Journals (Sweden)

    Ahmet Unlu, M.D.

    2016-01-01

    Full Text Available Vitamin C (ascorbic acid, ascorbate is a basic compound that is of great importance with its role in various enzymatic reactions including the synthesis of collagen, as well as with its redox functions. Vitamin C has become the center of interest in cancer studies, in consequence of the facts that connective tissue changes and vitamin C deficiency were first alleged to be associated with cancer in the 1950s; and that high doses of vitamin C was asserted to be cytotoxic for cancer cells, later on. The results of the first study carried out in the 1970s were promising; but afterwards, the studies were ascertained to be faulty. Despite the positive results achieved from some laboratory and animal experiments, randomized clinical trials did not verify those findings, and no clear benefit of vitamin C for cancer treatment could be demonstrated. As for studies, where its use in combination with other cancer treatment regimens was assessed, conflicting results were obtained. Although intake of high doses of vitamin C is alleged to be harmless, based on that it is in the group of water soluble vitamins and is not stored in the body, there are many side effects and drug interactions reported in the literature. For now, it is better to abstain from this treatment, until the benefit of the treatment (if any is clearly demonstrated, considering the potential side effects and interactions.

  20. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  1. Proconvulsant effects of high doses of venlafaxine in pentylenetetrazole-convulsive rats

    Directory of Open Access Journals (Sweden)

    J.G. Santos Junior

    2002-04-01

    Full Text Available Venlafaxine, an atypical antidepressant drug, has been used to treat several neurological disorders, presenting excellent efficacy and tolerability. Clinical seizures after venlafaxine treatment have occasionally been reported when the drug was used at very high doses or in combination with other medications. The aim of the present study was to investigate the convulsant effects of venlafaxine in rats under controlled laboratory conditions. Adult male Wistar rats (8 per group receiving venlafaxine or saline at the doses of 25-150 mg/kg were subjected 30 min later to injections of pentylenetetrazole at the dose of 60 mg/kg. The animals receiving 75, 100 and 150 mg/kg venlafaxine presented increased severity of convulsion when compared to controls (P = 0.02, P = 0.04, and P = 0.0004, respectively. Indeed, an increased percentage of death was observed in these groups (50, 38, and 88%, respectively when compared to the percentage of death in the controls (0%. The group receiving 150 mg/kg showed an reduction in death latency (999 ± 146 s compared to controls (1800 ± 0 s; cut-off time. Indeed, in this group, all animals developed seizures prior to pentylenetetrazole administration. Surprisingly, the groups receiving venlafaxine at the doses of 25 and 50 mg/kg showed a tendency towards an increase in the latency to the first convulsion. These findings suggest that venlafaxine at doses of 25 and 50 mg/kg has some tendency to an anticonvulsant effect in the rat, whereas doses of 75, 100 and 150 mg/kg presented clear proconvulsant effects in rats submitted to the pentylenetetrazole injection. These findings are the first report in the literature concerning the role of venlafaxine in seizure genesis in the rat under controlled conditions.

  2. Evaluation of doses from radiodiagnostic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners

    International Nuclear Information System (INIS)

    Veneziani, Glauco Rogerio

    2012-01-01

    The primary goal in veterinary radiography is to produce radiographs of diagnostic quality on the first attempt. This goal serves three purposes: (1) to decrease radiation exposure to the patient and veterinary personnel; (2) to decrease the cost of the study for the client; and (3) to produce diagnostic data for rapid interpretation and treatment of the patient. This work aimed to determine the doses in dogs submitted to chest and abdomen X rays using the technique of thermoluminescence (TL) dosimetry. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO 4 :Dy) and lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti). The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pet's owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics. (author)

  3. Absorbed Internal Dose Conversion Coefficients for Domestic Reference Animals and Plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-02-15

    This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, '9{sup 5}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, {sup 240}Pu) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (muGyd{sup -1} per Bqkg{sup -1}) ranged from 10{sup -6} to 10{sup -2} according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as {sup 238}U, {sup 239}Pu, and {sup 240}Pu, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of {sup 239}Pu, {sup 240}Pu, {sup 238}U, {sup 14}C, {sup 3}H and {sup 99}Tc were independent of the organism

  4. Can results from animal studies be used to estimate dose or low-dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1980-09-01

    A method has been developed based on animal data which appears useful in predicting biological equilibrium level for radionuclides in humans. It is shown that measures of whole-body retention, plasma concentration, short-term toxicity and cancer incidence can be projected, at least in limited circumstances, for some elements and organic compounds. Some of the procedures used for extrapolation in other fields as well as those from radiobiology are reviewed, the similarity procedure developed discussed, and a review provided of some of the issues in low-dose-effect modelling and the extrapolation of those data to humans

  5. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  6. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  7. Progress in high-dose radiation dosimetry

    International Nuclear Information System (INIS)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.; Chadwick, K.H.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expanded applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Reference systems also include a number of chemical dose meters: ferrous sulphate, ferrous-cupric sulphate, and ceric sulphate acidic aqueous solutions. Requirements for stable and reliable transfer dose meters have led to further developments of several important high-dose systems: amino acids and saccharides analysed by ESR or lyoluminescence, thermoluminescent materials, radiochromic dyes and plastics, ceric-cerous solutions analysed by potentiometry, and ethanol-chlorobenzene solutions analysed by high-frequency oscillometry. A number of other prospective dose meters are also treated in this review. In addition, an IAEA programme of high-dose standardization and intercomparison for industrial radiation processing is described. (author)

  8. Estimating Effective Dose from Phantom Dose Measurements in Atrial Fibrillation Ablation Procedures and Comparison of MOSFET and TLD Detectors in a Small Animal Dosimetry Setting

    Science.gov (United States)

    Anderson-Evans, Colin David

    Two different studies will be presented in this work. The first involves the calculation of effective dose from a phantom study which simulates an atrial fibrillation (AF) ablation procedure. The second involves the validation of metal-oxide semiconducting field effect transistors (MOSFET) for small animal dosimetry applications as well as improved characterization of the animal irradiators on Duke University's campus. Atrial Fibrillation is an ever increasing health risk in the United States. The most common type of cardiac arrhythmia, AF is associated with increased mortality and ischemic cerebrovascular events. Managing AF can include, among other treatments, an interventional procedure called catheter ablation. The procedure involves the use of biplane fluoroscopy during which a patient can be exposed to radiation for as much as two hours or more. The deleterious effects of radiation become a concern when dealing with long fluoroscopy times, and because the AF ablation procedure is elective, it makes relating the risks of radiation ever more essential. This study hopes to quantify the risk through the derivation of dose conversion coefficients (DCCs) from the dose-area product (DAP) with the intent that DCCs can be used to provide estimates of effective dose (ED) for typical AF ablation procedures. A bi-plane fluoroscopic and angiographic system was used for the simulated AF ablation procedures. For acquisition of organ dose measurements, 20 diagnostic MOSFET detectors were placed at selected organs in a male anthropomorphic phantom, and these detectors were attached to 4 bias supplies to obtain organ dose readings. The DAP was recorded from the system console and independently validated with an ionization chamber and radiochromic film. Bi-plane fluoroscopy was performed on the phantom for 10 minutes to acquire the dose rate for each organ, and the average clinical procedure time was multiplied by each organ dose rate to obtain individual organ doses. The

  9. Threshold dose for peripheral neuropathy following intraoperative radiotherapy (IORT) in a large animal model

    International Nuclear Information System (INIS)

    Kinsella, T.J.; DeLuca, A.M.; Barnes, M.; Anderson, W.; Terrill, R.; Sindelar, W.F.

    1991-01-01

    Radiation injury to peripheral nerve is a dose-limiting toxicity in the clinical application of intraoperative radiotherapy, particularly for pelvic and retroperitoneal tumors. Intraoperative radiotherapy-related peripheral neuropathy in humans receiving doses of 20-25 Gy is manifested as a mixed motor-sensory deficit beginning 6-9 months following treatment. In a previous experimental study of intraoperative radiotherapy-related neuropathy of the lumbro-sacral plexus, an approximate inverse linear relationship was reported between the intraoperative dose (20-75 Gy range) and the time to onset of hind limb paresis (1-12 mos following intraoperative radiotherapy). The principal histological lesion in irradiated nerve was loss of large nerve fibers and perineural fibrosis without significant vascular injury. Similar histological changes in irradiated nerves were found in humans. To assess peripheral nerve injury to lower doses of intraoperative radiotherapy in this same large animal model, groups of four adult American Foxhounds received doses of 10, 15, or 20 Gy to the right lumbro-sacral plexus and sciatic nerve using 9 MeV electrons. The left lumbro-sacral plexus and sciatic nerve were excluded from the intraoperative field to allow each animal to serve as its own control. Following treatment, a complete neurological exam, electromyogram, and nerve conduction studies were performed monthly for 1 year. Monthly neurological exams were performed in years 2 and 3 whereas electromyogram and nerve conduction studies were performed every 3 months during this follow-up period. With follow-up of greater than or equal to 42 months, no dog receiving 10 or 15 Gy IORT shows any clinical or laboratory evidence of peripheral nerve injury. However, all four dogs receiving 20 Gy developed right hind limb paresis at 8, 9, 9, and 12 mos following intraoperative radiotherapy

  10. Intracranial meningiomas after high-dose irradiation

    International Nuclear Information System (INIS)

    Soffer, D.; Gomori, J.M.; Siegal, T.; Shalit, M.N.

    1989-01-01

    Three patients who presented with intracranial meningiomas 12, 15, and 20 years, respectively, after therapeutic high-dose irradiation of a primary brain tumor are described. Analysis of these cases and similar documented cases suggests that meningiomas after high-dose irradiation constitute a recognizable entity. Patients with such tumors received radiation therapy at a young age (mean age, 9.4 years). After a latent period of 2 to 47 years (mean, 19.8 years) they developed meningiomas at the site of irradiation, at a much younger age than patients with ''spontaneous'' meningiomas. Similar to the situation with meningiomas after low-dose irradiation, a relatively high proportion of meningiomas induced by high-dose irradiation tend to be malignant and biologically aggressive. A very young age at the time of irradiation seems to predispose to the induction of malignant meningiomas, rather than benign tumors. These unusual features provide indirect evidence that high-dose radiation may play a role in the pathogenesis of meningiomas.41 references

  11. Effects of a single high dose of 55Fe in mice

    International Nuclear Information System (INIS)

    Laissue, J.A.; Burlington, H.; Cronkite, E.P.; Heldman, B.; Reincke, U.

    1979-01-01

    High doses of 55 Fe induced cytocide in maturing erythroid cells, due to the short-range deposition of decay energy. Organ damage at the time of death was evaluated in a group of 45 female mice of the C 57 BL/6 J strain given a single i.v. injection of 2,800 μCi, 1,400 μCi or 700 μCi of 55 FeCl 3 when 10 to 14 weeks old. A corresponding amount of cold iron was given to control animals by the same route. Radioiron-treated mice died spontaneously, or were killed when moribund. Mice given 2,800 μCi died after a median survival time of 27 days with severe depletion of hemopoietic cells in bone marrow and spleen, marked atrophy of lymphoid tissues and mild liver damage. After 1,400 μCi or 700 μCi, the median survival time was 117 and 439, respectively. In contrast, median survival was 847 days in control animals allowed to survive. In the two lower 55 Fe-dose groups, there was a dose-dependent pancytopenia. Atrophy of lymphoid tissues was moderate, and signs of liver damage slight. The degree of organ hemosiderosis in experimental and control animals was slight to moderate. Organ damage associated with deposition of cold iron was not apparent in tissue sections. Morphological signs of damage to non-hemopoietic organs such as the liver were not conspicuous. Direct radiation damage, primarily to the erythroid series, and competition for stem cells between the heavily depleted erythroid and the other hemopoietic cell lines must be considered among the possible factors leading to pancytopenia. Out of 14 55 Fe-treated mice who survived longer than 300 days developed tumors of hemopoietic and lymphoid tissues, or osteosarcomas. (orig./MG) [de

  12. Effects of neonatal thymic exposure to high doses of X-irradiation

    International Nuclear Information System (INIS)

    Bains, G.S.; Sundaram, K.

    1979-01-01

    The thymic region of neonatal Swiss mice was exposed to doses varying from 1000 R to 2000 R of X-irradiation. The animals did not show any signs of wasting syndrome up to 6 months after irradiation. At this time hyperplasia of the thymus with an associated lymphocytosis was evident in irradiated animals. Antibody production to sheep red blood cells (SRBC) was not affected. However, at 12 months post-irradiation the animals showed signs of wasting disease with a progressive increase in their numbers at 18 and 24 months of age. The percentage incidence of animals with wasting disease was dose dependent. At this stage in the majority of the animals with the disease the thymus showed varying degrees of atrophy along with splenomegaly. There were no significant differences in the number of lymphocytes but the number of granulocytes showed a substantial increase. This was more evident in animals exposed to 2000 R to the thymic region. Though one observed a lowered ability to form antibodies to bovine serum albumin (BSA) with advancing age, the thymic irradiation did not affect the immune response to BSA even in animals manifesting wasting disease. An interesting observation has been the development of a severe loss of muscle power and tone in the hind limbs in a large majority of animals. (author)

  13. Cancer radiotherapy based on femtosecond IR laser-beam filamentation yielding ultra-high dose rates and zero entrance dose.

    Science.gov (United States)

    Meesat, Ridthee; Belmouaddine, Hakim; Allard, Jean-François; Tanguay-Renaud, Catherine; Lemay, Rosalie; Brastaviceanu, Tiberius; Tremblay, Luc; Paquette, Benoit; Wagner, J Richard; Jay-Gerin, Jean-Paul; Lepage, Martin; Huels, Michael A; Houde, Daniel

    2012-09-18

    Since the invention of cancer radiotherapy, its primary goal has been to maximize lethal radiation doses to the tumor volume while keeping the dose to surrounding healthy tissues at zero. Sadly, conventional radiation sources (γ or X rays, electrons) used for decades, including multiple or modulated beams, inevitably deposit the majority of their dose in front or behind the tumor, thus damaging healthy tissue and causing secondary cancers years after treatment. Even the most recent pioneering advances in costly proton or carbon ion therapies can not completely avoid dose buildup in front of the tumor volume. Here we show that this ultimate goal of radiotherapy is yet within our reach: Using intense ultra-short infrared laser pulses we can now deposit a very large energy dose at unprecedented microscopic dose rates (up to 10(11) Gy/s) deep inside an adjustable, well-controlled macroscopic volume, without any dose deposit in front or behind the target volume. Our infrared laser pulses produce high density avalanches of low energy electrons via laser filamentation, a phenomenon that results in a spatial energy density and temporal dose rate that both exceed by orders of magnitude any values previously reported even for the most intense clinical radiotherapy systems. Moreover, we show that (i) the type of final damage and its mechanisms in aqueous media, at the molecular and biomolecular level, is comparable to that of conventional ionizing radiation, and (ii) at the tumor tissue level in an animal cancer model, the laser irradiation method shows clear therapeutic benefits.

  14. Mechanism of action for anti-radiation vaccine in reducing the biological impact of high-dose gamma irradiation

    Science.gov (United States)

    Maliev, Vladislav; Popov, Dmitri; Jones, Jeffrey A.; Casey, Rachael C.

    Ionizing radiation is a major health risk of long-term space travel, the biological consequences of which include genetic and oxidative damage. In this study, we propose an original mechanism by which high doses of ionizing radiation induce acute toxicity. We identified biological components that appear in the lymphatic vessels shortly after high-dose gamma irradiation. These radiation-induced toxins, which we have named specific radiation determinants (SRD), were generated in the irradiated tissues and then circulated throughout the body via the lymph circulation and bloodstream. Depending on the type of SRD elicited, different syndromes of acute radiation sickness (ARS) were expressed. The SRDs were developed into a vaccine used to confer active immunity against acute radiation toxicity in immunologically naïve animals. Animals that were pretreated with SRDs exhibited resistance to lethal doses of gamma radiation, as measured by increased survival times and survival rates. In comparison, untreated animals that were exposed to similar large doses of gamma radiation developed acute radiation sickness and died within days. This phenomenon was observed in a number of mammalian species. Initial analysis of the biochemical characteristics indicated that the SRDs were large molecular weight (200-250 kDa) molecules that were comprised of a mixture of protein, lipid, carbohydrate, and mineral. Further analysis is required to further identify the SRD molecules and the biological mechanism by which they mediate the toxicity associated with acute radiation sickness. By doing so, we may develop an effective specific immunoprophylaxis as a countermeasure against the acute effects of ionizing radiation.

  15. High-dose irradiation of food

    International Nuclear Information System (INIS)

    Diehl, J.F.

    1999-01-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [de

  16. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  17. Tumour induction by small doses of ionised radiation

    International Nuclear Information System (INIS)

    Putten, L.M. van

    1980-01-01

    The effect of low doses of ionised radiation on tumour induction in animals is discussed. It is hypothesised that high doses of radiation can strongly advance tumour induction from the combination of a stimulated cell growth, as a reaction to massive cell killing, and damage to DNA in the cell nuclei. This effect has a limit below which the radiation dose causes a non-significant amount of dead cells. However in animals where through other reasons, a chronic growth stimulation already exists, only one effect, the damage of DNA, is necessary to induce tumours. A linear dose effect without a threshold level applies in these cases. Applying this hypothesis to man indicates that calculating low dose effects by linear extrapolation of high dose effects is nothing more than a reasonable approximation. (C.F.)

  18. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  19. A NEW ANIMAL-MODEL FOR HUMAN PREECLAMPSIA - ULTRA-LOW-DOSE ENDOTOXIN INFUSION IN PREGNANT RATS

    NARCIS (Netherlands)

    FAAS, MM; SCHUILING, GA; BALLER, JFW; VISSCHER, CA; BAKKER, WW

    OBJECTIVE: An animal model for preeclampsia was developed by means of an ultra-low-dose endotoxin infusion protocol in conscious pregnant rats. STUDY DESIGN: Rats received a permanent jugular vein cannula on day 0 of pregnancy, through which endotoxin (1.0 mu/kg body weight) (n = 10) or saline

  20. Performance of thermoluminescent materials for high dose dosimetry

    International Nuclear Information System (INIS)

    Texeira, Maria I.; Cecatti, Sonia G.P.; Caldas, Linda V.E.

    2008-01-01

    Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. The reproducibility, the lower detection limits and dose-response curves were obtained for all three materials. The different kinds of detectors show usefulness for dosimetry of workers exposed accidentally to high doses. (author)

  1. In vivo variation of micronuclei in BALB/c mice after low and high doses of gamma radiation

    International Nuclear Information System (INIS)

    Strain, D.; Allen, B.J.

    1996-01-01

    Full text: An adaptive response to ionising radiation exists if a low level or priming dose reduces the effect of a subsequent high or challenge dose. This has been demonstrated in vitro using the frequency of micronuclei formation as a measure of radiation-induced DNA damage. The objective of this project was to use the same approach with an animal model to investigate the existence of an in vivo adaptive response. The experimental design involved priming doses of 0.005 or 0.01 Gy and a challenge dose of 4 Gy administered 1, 2, 4, 8 or 16 hours after the priming dose. Ten mice at a time were housed in a perspex animal cage and irradiated using Co-60 gamma radiation. For every time point (1, 2, 4, 8 or 16 hours), there were four treatment groups of 5 mice for statistical analysis. The first group acted as a non-irradiated control (0 Gy). The second group of mice received only the priming dose (0.005 Gy), while the third group of mice received only the challenge dose (4 Gy). The fourth group of mice received both the priming and challenge doses 0.005 Gy + 4 Gy). The process was repeated for the second priming dose of 0.01 Gy. A total of 200 mice were used. The animals were sacrificed by cervical dislocation 24 hours after receiving the challenge dose. Both femora were removed and cleared of adhering muscle tissue. The bone marrow cells of five mice were collected and the nucleated cells removed using filtration through a mixed cellulose column incorporating a self-locking filter. The cell suspension was placed onto microscope slides using a cytocentrifuge, air-dried and then stained for the micronuclei. Then the slides were coded, and reticulocytes were scored for the presence or absence of micronuclei. Approximately 2500 cells were scored for each treatment point, and the number of micronuclei counted ranged from 3 to 125 in this sample size. While it appears that the adaptive response may be present in 2 of 9 groups of mice pre-exposed to 0.005 or 0.01 Gy, this

  2. Preclinical assessment of HIV vaccines and microbicides by repeated low-dose virus challenges.

    Directory of Open Access Journals (Sweden)

    Roland R Regoes

    2005-08-01

    Full Text Available Trials in macaque models play an essential role in the evaluation of biomedical interventions that aim to prevent HIV infection, such as vaccines, microbicides, and systemic chemoprophylaxis. These trials are usually conducted with very high virus challenge doses that result in infection with certainty. However, these high challenge doses do not realistically reflect the low probability of HIV transmission in humans, and thus may rule out preventive interventions that could protect against "real life" exposures. The belief that experiments involving realistically low challenge doses require large numbers of animals has so far prevented the development of alternatives to using high challenge doses.Using statistical power analysis, we investigate how many animals would be needed to conduct preclinical trials using low virus challenge doses. We show that experimental designs in which animals are repeatedly challenged with low doses do not require unfeasibly large numbers of animals to assess vaccine or microbicide success.Preclinical trials using repeated low-dose challenges represent a promising alternative approach to identify potential preventive interventions.

  3. Fiber optics in high dose radiation fields

    International Nuclear Information System (INIS)

    Partin, J.K.

    1985-01-01

    A review of the behavior of state-of-the-art optical fiber waveguides in high dose (greater than or equal to 10 5 rad), steady state radiation fields is presented. The influence on radiation-induced transmission loss due to experimental parameters such as dose rate, total dose, irradiation history, temperature, wavelength, and light intensity, for future work in high dose environments are given

  4. A high resolution small animal radiation research platform (SARRP) with x-ray tomographic guidance capabilities

    Science.gov (United States)

    Wong, John; Armour, Elwood; Kazanzides, Peter; Iordachita, Iulian; Tryggestad, Erik; Deng, Hua; Matinfar, Mohammad; Kennedy, Christopher; Liu, Zejian; Chan, Timothy; Gray, Owen; Verhaegen, Frank; McNutt, Todd; Ford, Eric; DeWeese, Theodore L.

    2008-01-01

    Purpose To demonstrate the CT imaging, conformal irradiation and treatment planning capabilities of a small animal radiation research platform (SARRP). Methods The SARRP employs a dual-focal spot, constant voltage x-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120° from vertical. Eighty to 100 kVp x-rays from the smaller 0.4 mm focal spot are used for imaging. Both 0.4 mm and 3.0 mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam (CB) CT imaging is achieved by rotating the horizontal animal between the stationary x-ray source and a flat-panel detector. Radiation beams range from 0.5 mm in diameter to (60 × 60) mm2. Dosimetry is measured with radio-chromic films. Monte Carlo dose calculations are employed for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. Results The SARRP spans 3 ft × 4 ft × 6 ft (WxLxH). Depending on filtration, the isocenter dose outputs at 1 cm depth in water range from 22 to 375 cGy/min from the smallest to the largest radiation fields. The 20% to 80% dose fall-off spans 0.16 mm. CBCT with (0.6 × 0.6 × 0.6) mm3 voxel resolution is acquired with less than 1 cGy. Treatment planning is performed at sub-mm resolution. Conclusions The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation. PMID:18640502

  5. Radiophotoluminescence light scope for high-dose dosimetry

    International Nuclear Information System (INIS)

    Sato, Fuminobu; Zushi, Naoki; Sakiyama, Tomoki; Kato, Yushi; Murata, Isao; Shimizu, Kikuo; Yamamoto, Takayoshi; Iida, Toshiyuki

    2015-01-01

    A radiophotoluminescence (RPL) light scope is a remote-sensing technique for measuring in situ the radiation dose in an RPL detector placed at a distance. The RPL light scope is mainly composed of an ultraviolet (UV) pulse laser, telescopic lenses, a photomultiplier tube, and camera modules. In a performance test, some RPL detectors were placed at distances up to 30 m and were illuminated with a pulsed UV laser beam. The photoluminescence responses of the RPL detectors were analyzed using this scope. Their radiation doses were determined from the amplitude of the given component of the photoluminescence responses. The RPL readout could be repeated without fading, and its amplitude exhibited good linearity at a dose ranging from 0.1 to 60 Gy. Furthermore, a two-dimensional distribution of radiation dose was obtained by laser scanning on an RPL detector. It was confirmed that the RPL light scope was a useful remote-sensing tool for high-dose dosimetry. - Highlights: • A radiophotoluminescence (RPL) light scope was developed for high-dose dosimetry. • The RPL light scope has high sensitivity and accuracy in high-dose dosimetry. • Two-dimensional radiation dose distribution was obtained by the RPL light scope.

  6. High-dose dosimetry using natural silicate minerals

    International Nuclear Information System (INIS)

    Carmo, Lucas S. do; Mendes, Leticia; Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina; Barbosa, Renata F.

    2015-01-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  7. High-dose dosimetry using natural silicate minerals

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Mendes, Leticia, E-mail: isatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina, E-mail: lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear; Barbosa, Renata F., E-mail: profcelta@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil). Departamento de Ciencias do Mar

    2015-07-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  8. Radionuclides in Animal Feed (Poultry) 'Assessment of Radiation Dose'

    Energy Technology Data Exchange (ETDEWEB)

    Algadi, S.; Salih, I. [Radiation Safety Institute (Sudan)

    2014-07-01

    In this work a comprehensive study has been carried out for the determination of presents evaluation of effective dose due to consumption of chicken fed by fodders collected from four major Sudanese companies (Hader, Koudjs, Wifi and Preconex SPN.V). The concentrations of radionuclides in the thirty two (32) feed samples have been determined by gamma spectrometry using NaI(Tl) detector. Radionuclides observed were: Pb-212 (daughter of Th-238), Pb-214, Bi-214 (daughters of U-238), Cs-137 and K-40 concentration. In additives the activity concentration of these radionuclides has found in the following ranges: 0.81 - 22.06 Bq/kg, 0.59 - 32.07 Bq/kg, 0.64 - 15.77 Bq/kg, 0.01 - 2.02 Bq/kg and 33.58 - 204.61 Bq/kg respectively. In feed concentrates activity concentration ranges has: 0.73 - 13.79 Bq/kg, 0.33 - 20.04 Bq/kg, 0.01 - 1.67 Bq/kg, 0.01 - 0.28 Bq/kg, 26.86 - 99.21 Bq/kg respectively. In fodders the activity concentration ranges has: 1.25 - 1.52 Bq/kg, 0.12 - 1.24 Bq/kg, 0.51 - 1.25 Bq/kg, 0.01 - 0.61 Bq/kg, 11.94 - 127.88 Bq/kg respectively. The 'animal product' activity concentration ranges has: 0.31 - 1.65 Bq/kg, 0.22 - 1.11 Bq/kg, 0.26 - 1.07 Bq/kg, 0.03 - 0.51 Bq/kg, 14.07 - 79.93 Bq/kg respectively. High concentrations (233.3 Bq/Kg) has typically found in toxo(additive); the lowest concentration (27.9 Bq/Kg ) has found in concentrate for layers and animal product. The total average effective dose due to the different feed-stuff has estimated and found to be 5.89x10{sup -6}±3.11x10{sup -6}mSv/y and 13.9 x 10{sup -7} ± 7.24 x 10{sup -7}mSv/y for age categories 7-12 y and >17 y respectively. If compared with the limits - Radioactivity Levels Permitted in foodstuffs Part 1 the Saudi Standards, Metrology and quality (300 Bq/Kg) and ICRP,FAO organization (5 mSv/y) - these values are very low. Document available in abstract form only. (authors)

  9. Dose prediction for plants and animals - nuclear fuel waste management perspective

    International Nuclear Information System (INIS)

    Zach, R.; Amiro, B.

    1997-01-01

    We have developed a comprehensive, practical ecological radiation assessment methodology and applied it in the environmental impact statement (EIS) for evaluating the safety of Canada's nuclear fuel waste disposal concept. The methodology has four screening steps, and we focus here on the last two concerned with dose estimation for . plants and animals. We present ten classes of issues that were compiled from comments regarding our methodology from EIS review participants. Furthermore, we identify future needs and developments for improving our methodology. The issues raised by EIS participants, and the future needs and developments indicated by us are also of general importance in guiding future work. (author)

  10. Pharmacokinetics and pharmacodynamics of MD1003 (high-dose biotin) in the treatment of progressive multiple sclerosis.

    Science.gov (United States)

    Peyro Saint Paul, Laure; Debruyne, Danièle; Bernard, Delphine; Mock, Donald M; Defer, Gilles L

    2016-01-01

    Multiple sclerosis (MS) is a chronic, potentially highly disabling neurological disorder. No disease-modifying treatments are approved in the progressive and not active forms of the disease. High doses of biotin were tested in an open-label pilot study involving 23 patients with progressive MS and reported positive results. A randomized, double-blind, placebo-controlled trial in 154 progressive MS patients confirmed the beneficial effect of MD1003 (high-dose biotin) on reversing or stabilizing disability progression, with a good safety profile. It is proposed that MD1003 in progressive MS 1) increases energy production in demyelinated axons and/or 2) enhances myelin synthesis in oligodendrocytes. Biotin is highly bioavailable; absorption and excretion are rapid. The major route of elimination is urinary excretion. A high oral dose of biotin seems generally well tolerated but a few important safety concerns were identified: 1) teratogenicity in one species and 2) interference with some biotin-based laboratory immunoassays. The animal toxicity data are limited at such high doses. Further preclinical studies would be useful to address the mechanism of action of MD1003. Assessment of clinical benefit duration in responders will be also very important to set. Results of randomized, placebo-controlled trial are reassuring and provide hope for the treatment of progressive MS.

  11. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  12. The carcinogenic risk of high dose total body irradiation in non-human primates

    International Nuclear Information System (INIS)

    Broerse, J.J.; Bartstra, R.W.; Bekkum, D.W. van; Hage, M.H. van der; Zurcher, C.; Zwieten, M.J. van; Hollander, C.F.

    2000-01-01

    High dose total body irradiation (TBI) in combination with chemotherapy, followed by rescue with bone marrow transplantation (BMT), is increasingly used for the treatment of haematological malignancies. With the increasing success of this treatment and its current introduction for treating refractory autoimmune diseases the risk of radiation carcinogenesis is of growing concern. Studies on turnout induction in non-human primates are of relevance in this context since the response of this species to radiation does not differ much from that in man. Since the early sixties, studies have been performed on acute effects in Rhesus monkeys and the protective action of bone marrow transplantation after irradiation with X-rays (average total body dose 6.8 Gy) and fission neutrons (average dose 3.4 Gy). Of those monkeys, which were irradiated and reconstituted with autologous bone marrow, 20 animals in the X-irradiated group and nine animals in the neutron group survived more than 3 years. A group of 21 non-irradiated Rhesus monkeys of a comparable age distribution served as controls. All animals were regularly screened for the occurrence of neoplasms. Complete necropsies were performed after natural death or euthanasia. At post-irradiation intervals of 4-21 years an appreciable number of tumours was observed. In the neutron irradiated group eight out of nine animals died with one or more malignant tumours. In the X-irradiated group this fraction was 10 out of 20. The tumours in the control group, in seven out of the 21 animals, appeared at much older a-e compared with those in the irradiated cohorts. The histogenesis of the tumours was diverse with a preponderance of renal carcinoma, sarcomas among which osteosarcormas, and malignant glomus tumours in the irradiated groups. When corrected for competing risks, the carcinogenic risk of TBI in the Rhesus monkeys is similar to that derived from the studies of the Japanese atomic bomb survivors. The increase of the risk by a

  13. High dose gamma-ray standard

    International Nuclear Information System (INIS)

    Macrin, R.; Moraru, R.

    1999-01-01

    The high gamma-ray doses produced in a gamma irradiator are used, mainly, for radiation processing, i.e. sterilization of medical products, processing of food, modifications of polymers, irradiation of electronic devices, a.s.o. The used absorbed doses depend on the application and cover the range 10 Gy to 100 MGy. The regulations in our country require that the response of the dosimetry systems, used for the irradiation of food and medical products, be calibrated and traceable to the national standards. In order to be sure that the products receive the desired absorbed dose, appropriate dosimetric measurements must be performed, including the calibration of the dosemeters and their traceability to the national standards. The high dose gamma-ray measurements are predominantly based on the use of reference radiochemical dosemeters. Among them the ferrous sulfate can be used as reference dosemeter for low doses (up to 400 Gy) but due to its characteristics it deserves to be considered a standard dosemeter and to be used for transferring the conventional absorbed dose to other chemical dosemeters used for absorbed doses up to 100 MGy. The study of the ferrous sulfate dosemeter consisted in preparing many batches of solution by different operators in quality assurance conditions and in determining for all batches the linearity, the relative intrinsic error, the repeatability and the reproducibility. The principal results are the following: the linear regression coefficient: 0.999, the relative intrinsic error: max.6 %, the repeatability (for P* = 95 %): max.3 %, the reproducibility (P* = 95%): max.5 %. (authors)

  14. Low-dose-rate high-let radiation cytogenetic effects on mice in vivo as model of space radiation action on mammalian

    Science.gov (United States)

    Sorokina, Svetlana; Zaichkina, Svetlana; Rozanova, Olga; Aptikaeva, Gella; Romanchenko, Sergei; Smirnova, Helene; Dyukina, Alsu; Peleshko, Vladimir

    At present time little is known concerning the biological effects of low-dose-rate high-LET radiation exposure in space. The currently available experimental data on the biological effect of low doses of chronic radiation with high-LET values, which occur under the conditions of aircraft and space flights, have been primarily obtained in the examinations of pilots and astronauts after flights. Another way of obtaining this kind of evidence is the simulation of irradiation conditions during aircraft and space flights on high-energy accelerators and the conduction of large-scale experiments on animals under these conditions on Earth. In the present work, we investigated the cytogenetic effects of low-dose-rate high-LET radiation in the dose ranges of 0.2-30 cGy (1 cGy/day) and 0.5-16 cGy (0.43 cGy/day) in the radiation field behind the concrete shield of the Serpukhov accelerator of 70 GeV protons that simulates the spectral and component composition of radiation fields formed in the conditions of high-altitude flights on SHK mice in vivo. The dose dependence, adaptive response (AR) and the growth of solid tumor were examined. For induction of AR, two groups of mice were exposed to adapting doses of 0.2-30 cGy and the doses of 0.5-16 cGy of high-LET radiation. For comparison, third group of mice from unirradiated males was chronically irradiated with X-rays at adapting doses of 10 cGy (1 cGy/day). After a day, the mice of all groups were exposed to a challenging dose of 1.5 Gy of X-rays (1 Gy/min). After 28 h, the animals of all groups were killed by the method of cervical dislocation. Bone marrow specimens for calculating micronuclei (MN) in polychromatic erythrocytes (PCE) were prepared by a conventional method with minor modifications. The influence of adapting dose of 16 cGy on the growth of solid tumor of Ehrlich ascite carcinoma was estimated by measuring the size of the tumor at different times after the inoculation of ascitic cells s.c. into the femur. It was

  15. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  16. ELDRS Characterization for a Very High Dose Mission

    Science.gov (United States)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  17. SR-TXRF analysis of trace elements in whole blood and heart of rats: effects of irradiation with low and high doses

    Science.gov (United States)

    Mota, C. L.; Pickler, A.; Braz, D.; Barroso, R. C.; Mantuano, A.; Salata, C.; Ferreira-Machado, S. C.; Lau, C. C.; de Almeida, C. E.

    2018-04-01

    In the last decades, studies showed that the exposure to low doses of ionizing radiation of the body could sense and activate the cell signaling pathways needed to respond to any induced cellular damage. This procedure reduces cell killing compared with a single dose of high radiation dose. Damage to the vasculature can affect the function of most body organs by restricting blood flow and oxygen to tissues; however, the heart and brain are of main concern. The precise relationship between long-term health effects and low-dose exposures remain poorly understood. Biological markers are powerful tools that can be used to determine dose- response relationships and to estimate risk, especially when dealing with, the effects of low dose exposures in humans. These markers should be specific, sensitive, as well as easy and fast to quantify. Various types of biologic specimens are potential candidates for identifying biomarkers but blood has the advantage of being minimally invasive to obtain. In this study, we propose to apply total reflection X-ray fluorescence to quantify possible chemical elemental concentration (sulfer, iron, zinc, potassium and calcium) changes in blood and heart tissues of Wistar rats after total body irradiation with low (0.1 Gy) and high (2.5 Gy) doses. The fluorescence measurements were carried out at the X-ray Fluorescence beamline in the Brazilian Synchrotron Light Laboratory. The results showed that the irradiated animals with low doses have significant alterations in blood and cardiac tissue when compared with animals that received high doses of radiation. Taken together the analysis of all the elements, we can observe that the radiation induced oxidative stress may be the leading cause for alteration of the elemental level in the studied samples.

  18. Radiation stability of animate nature

    International Nuclear Information System (INIS)

    Romanov, G.N.; Spirin, D.A.

    1990-01-01

    The main principles of radiation safety for animate nature including provisions for biological species protection and main requirement for animate nature radiation protection, which is the guarantee of any ecosystem integrity, are discussed. Ecosystem should be taken as the objective unit for animate nature radiation protection. The maximum dose of biot irradiation may amount to 0.5 Gy/year, which is 20-fold lower than the main dose limit for animate nature and 40-fold lower than ecological dose limits for conifers as the weakest radiostable member in ecosystem, at environment radioactive contamination determined by radiation safety standards. The radiation protection of animate nature is guaranteed at such levels of environment radioactive contamination

  19. The Increase in Animal Mortality Risk following Exposure to Sparsely Ionizing Radiation Is Not Linear Quadratic with Dose.

    Directory of Open Access Journals (Sweden)

    Benjamin M Haley

    Full Text Available The US government regulates allowable radiation exposures relying, in large part, on the seventh report from the committee to estimate the Biological Effect of Ionizing Radiation (BEIR VII, which estimated that most contemporary exposures- protracted or low-dose, carry 1.5 fold less risk of carcinogenesis and mortality per Gy than acute exposures of atomic bomb survivors. This correction is known as the dose and dose rate effectiveness factor for the life span study of atomic bomb survivors (DDREFLSS. It was calculated by applying a linear-quadratic dose response model to data from Japanese atomic bomb survivors and a limited number of animal studies.We argue that the linear-quadratic model does not provide appropriate support to estimate the risk of contemporary exposures. In this work, we re-estimated DDREFLSS using 15 animal studies that were not included in BEIR VII's original analysis. Acute exposure data led to a DDREFLSS estimate from 0.9 to 3.0. By contrast, data that included both acute and protracted exposures led to a DDREFLSS estimate from 4.8 to infinity. These two estimates are significantly different, violating the assumptions of the linear-quadratic model, which predicts that DDREFLSS values calculated in either way should be the same.Therefore, we propose that future estimates of the risk of protracted exposures should be based on direct comparisons of data from acute and protracted exposures, rather than from extrapolations from a linear-quadratic model. The risk of low dose exposures may be extrapolated from these protracted estimates, though we encourage ongoing debate as to whether this is the most valid approach. We also encourage efforts to enlarge the datasets used to estimate the risk of protracted exposures by including both human and animal data, carcinogenesis outcomes, a wider range of exposures, and by making more radiobiology data publicly accessible. We believe that these steps will contribute to better estimates

  20. Data base on animal mortality

    International Nuclear Information System (INIS)

    Jones, T.D.

    1987-01-01

    A data base on animal mortality has been compiled. The literature on LD 50 and the dose-response function for radiation-induced lethality, reflect several inconsistencies - primarily due to dose assignments and to analytical methods and/or mathematical models used. Thus, in order to make the individual experiments which were included in the data base as consistent as possible, an estimate of the uniform dose received by the bone marrow in each treatment group was made so that the interspecies differences are minimized. The LD 50 was recalculated using a single estimation procedure for all studies for which sufficient experimental data are available. For small animals such as mice, the dose to the hematopoietic system is approximately equal to the treatment dose, but for large animals the marrow dose may be about half of the treatment dose

  1. High doses of L-naloxone but neither D-naloxone nor beta-funaltrexamine prevent hyperthermia-induced seizures in rat pups.

    Science.gov (United States)

    Laorden, M L; Miralles, F S; Puig, M M

    1988-03-01

    The effects of the non-specific opiate antagonist L-naloxone and the inactive isomer D-naloxone, as well as the specific mu receptor antagonist beta-funaltrexamine, have been examined on hyperthermia-induced seizures in unrestrained 15 days old rats. Saline-injected animals exposed to an ambient temperature of 40 degrees C showed a gradual increase in body temperature reaching a maximum of 42 +/- 0.1 degrees C at 50 min exposure. At this time all the pups had seizures and died. Similar results were obtained when the animals were pretreated with different doses of D-naloxone and beta-funaltrexamine. Rats pretreated with L-naloxone also showed an increase in rectal temperature; but the temperature was lower than in saline-injected animals. Only high doses of L-naloxone prevented seizures and deaths. These data indicate that endogenous opioid peptides may play a role in seizures induced by hyperthermia and that receptors other than mu receptors could be involved in hyperthermia-induced seizures.

  2. Quality control of 192Ir high dose rate after loading brachytherapy dose veracity

    International Nuclear Information System (INIS)

    Feng Zhongsu; Xu Xiao; Liu Fen

    2008-01-01

    Recently, 192 Ir high dose rate (HDR) afterloading are widely used in brachytherapy. The advantage of using HDR systems over low dose rate systems are shorter treatment time and higher fraction dose. To guarantee the veracity of the delivery dose, several quality control methods are deseribed in this work. With these we can improve the position precision, time precision and dose precision of the brachytherapy. (authors)

  3. High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Skwarchuk, Mark W.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1997-01-01

    Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters are afterloaded with two 192 Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th 12 -L 2 . Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED 50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED 50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED 50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the

  4. Pharmacokinetically guided dosing of (high-dose) chemotherapeutic agents

    NARCIS (Netherlands)

    Attema-de Jonge, M.E. (Milly Ellen)

    2004-01-01

    Due to variation in drug distribution, metabolism and elimination processes between patients, systemic exposure to chemotherapeutic agents may be highly variable from patient to patient after administration of similar doses. This pharmacokinetic variability may explain in part the large variability

  5. Life-span studies in 226Ra-injected animals: Effect of low doses, effect of a decorporative treatment

    International Nuclear Information System (INIS)

    Schoeters, G.E.R.; Vanderborght, O.L.J.

    1986-01-01

    A life-span radiation effects study was performed in mice injected with several doses of 226 Ra. The study included 788 male C57Bl mice. For the removal of the 226 Ra, half the mice were treated daily with a diet 5% of which was sodium-alginate. The experiment revealed that mice that received the lowest dose of 226 Ra lived significantly longer than controls, and, despite appreciable skeletal removal of 226 Ra as a result of decorporative treatment, no biological benefit was observed in treated animals. 19 refs., 4 figs., 3 tabs

  6. Fundamental image quality limits for microcomputed tomography in small animals

    International Nuclear Information System (INIS)

    Ford, N.L.; Thornton, M.M.; Holdsworth, D.W.

    2003-01-01

    Small-animal imaging has become increasingly more important as transgenic and knockout mice are produced to model human diseases. One imaging technique that has emerged is microcomputed tomography (micro-CT). For live-animal imaging, the precision in the images will be determined by the x-ray dose given to the animal. As a result, we propose a simple method to predict the noise performance of an x-ray micro-CT system as a function of dose and image resolution. An ideal, quantum-noise limited micro-CT scanner, assumed to have perfect resolution and ideal efficiency, was modeled. Using a simplified model, the coefficient of variation (COV) of the linear attenuation coefficient was calculated for a range of entrance doses and isotropic voxel sizes. COV calculations were performed for the ideal case and with simulated imperfections in efficiency and resolution. Our model was validated in phantom studies and mouse images were acquired with a specimen scanner to illustrate the results. A simplified model of noise propagation in the case of isotropic resolution indicates that the COV in the linear attenuation coefficient is proportional to (dose) -1/2 and to the (isotropic voxel size) -2 in the reconstructed volume. Therefore an improvement in the precision can be achieved only by increasing the isotropic voxel size (thereby decreasing the resolution of the image) or by increasing the x-ray dose. For the ideal scanner, a COV of 1% in the linear attenuation coefficient for an image of a mouse exposed to 0.25 Gy is obtained with a minimum isotropic voxel size of 135 μm. However, the same COV is achieved at a dose of 5.0 Gy with a 65 μm isotropic voxel size. Conversely, for a 68 mm diameter rat, a COV of 1% obtained from an image at 5.0 Gy would require an isotropic voxel size of 100 μm. These results indicate that short-term, potentially lethal, effects of ionizing radiation will limit high-resolution live animal imaging. As improvements in detector technology allow the

  7. A dose-response study in animals to evaluate the anticoagulant effect of the stage 2 unfractionated heparin USP monograph change.

    Science.gov (United States)

    Honchel, R; Carraway, J; Gopee, N; Callicott, R; Chen, J; Patton, R; Xu, Q; Zalkkar, J; Laniyonu, A; Krefting, I; Cato, M; Robie-Suh, K; Rieves, R

    2011-08-01

    The United States Pharmacopeia (USP) monograph for unfractionated heparin (UFH) was revised in October 2009. This revision was anticipated, based upon in vitro tests, to reduce UFH potency by approximately 10%. To study the potential in vivo consequences of the monograph change, we evaluated activated partial thromboplastin time (aPTT) and activated clotting time (ACT) responses in animals. Female mini-pigs and monkeys (n=8/species) were administered intravenously 60, 54, 48, or 42 U/kg and 50, 45, 40, or 35 U/kg "old" (pre-USP revision) UFH, respectively, in a Williams 4×4 crossover design. Blood samples for aPTT and ACT were collected at 15 min after dosing. The same study design was then repeated using "new" (post-USP revision) UFH. Mean "new" UFH aPTT and ACT values were generally lower than those for "old" UFH although individual animal responses varied considerably. The aPTT and ACT response was generally dose-proportional for both "old" and "new" UFH. These studies indicate that the USP monograph alteration for UFH may result in a modest reduction in the anticoagulant response across a population, but the variability in animal responses underscores the importance of individualization of clinical UFH dosing and the importance of anticoagulant test monitoring. Published by Elsevier Inc.

  8. Accuracy and Radiation Dose of CT-Based Attenuation Correction for Small Animal PET: A Monte Carlo Simulation Study

    International Nuclear Information System (INIS)

    Yang, Ching-Ching; Chan, Kai-Chieh

    2013-06-01

    -Small animal PET allows qualitative assessment and quantitative measurement of biochemical processes in vivo, but the accuracy and reproducibility of imaging results can be affected by several parameters. The first aim of this study was to investigate the performance of different CT-based attenuation correction strategies and assess the resulting impact on PET images. The absorbed dose in different tissues caused by scanning procedures was also discussed to minimize biologic damage generated by radiation exposure due to PET/CT scanning. A small animal PET/CT system was modeled based on Monte Carlo simulation to generate imaging results and dose distribution. Three energy mapping methods, including the bilinear scaling method, the dual-energy method and the hybrid method which combines the kVp conversion and the dual-energy method, were investigated comparatively through assessing the accuracy of estimating linear attenuation coefficient at 511 keV and the bias introduced into PET quantification results due to CT-based attenuation correction. Our results showed that the hybrid method outperformed the bilinear scaling method, while the dual-energy method achieved the highest accuracy among the three energy mapping methods. Overall, the accuracy of PET quantification results have similar trend as that for the estimation of linear attenuation coefficients, whereas the differences between the three methods are more obvious in the estimation of linear attenuation coefficients than in the PET quantification results. With regards to radiation exposure from CT, the absorbed dose ranged between 7.29-45.58 mGy for 50-kVp scan and between 6.61-39.28 mGy for 80-kVp scan. For 18 F radioactivity concentration of 1.86x10 5 Bq/ml, the PET absorbed dose was around 24 cGy for tumor with a target-to-background ratio of 8. The radiation levels for CT scans are not lethal to the animal, but concurrent use of PET in longitudinal study can increase the risk of biological effects. The

  9. Conditioned instrumental behaviour in the rat: Effects of prenatal irradiation with various low dose-rate doses. Instrumentelle Verhaltensuntersuchungen an der Ratte: Ueber die Wirkung verschiedener Dosen einer praenatalen Bestrahlung niedriger Dosisleistung

    Energy Technology Data Exchange (ETDEWEB)

    Klug, H.

    1986-01-01

    4 groups of rats of the Wistar-strain were subjected to ..gamma..-irradiation on the 16th day of gestation. 5 rats received 0,6 Gy low dose rate irradiation, 5 animals received 0,9 Gy low dose and 6 high dose irradiation, 3 females were shamirradiated. The male offspring of these 3 irradiation groups and 1 control group were tested for locomotor coordination on parallel bars and in a water maze. The female offspring were used in an operant conditioning test. The locomotor test showed slight impairment of locomotor coordination in those animals irradiated with 0,9 Gy high dose rate. Swimming ability was significantly impaired by irradiation with 0,9 Gy high dose rate. Performance in the operant conditioning task was improved by irradiation with 0,9 Gy both low and high dose rate. The 0,9 Gy high dose rate group learned faster than all the other groups. For the dose of 0,9 Gy a significant dose rate effect could be observed. For the dose of 0,6 Gy a similar tendency was observed, differences between 0,6 Gy high and low dose rate and controls not being significant.

  10. Physiological and immunological changes following exposure to low versus high-dose ionizing irradiation; comparative analysis with dose rate and cumulative dose

    International Nuclear Information System (INIS)

    Heesun, Kim; Heewon, Jang; Soungyeon, Song; Shinhye, Oh; Cukcheul, Shin; Meeseon, Jeong; Chasoon, Kim; Kwnaghee, Yang; Seonyoung, Nam; Jiyoung, Kim; Youngwoo, Jin; Changyoung, Cha

    2008-01-01

    Full text: While high-dose of ionizing radiation is generally harmful and causes damage to living organisms some reports suggest low-dose of radiation may not be as damaging as previously thought. Despite increasing evidence regarding the protective effect of low-dose radiation, no studies have directly compared the exact dose-response pattern by high- and low-dose of radiation exposed at high-and low-dose rate. This study aims to explore the cellular and molecular changes in mice exposed to low- and high-dose of radiation exposed at low- and high-dose rate. When C57BL/6 mice (Female, 6 weeks) were exposed at high-dose rate, 0.8 Gy/min, no significant change on the level of WBC, RBC, or platelets was observed up to total dose of 0.5 Gy. However, 2 Gy of radiation caused dramatic reduction in the level of white blood cells (WBC) and platelets. This reduction was accompanied by increased DNA damage in hematopoietic environments. The reduction of WBC was mainly due to the reduction in the number of CD4+ T cells and CD19+ B cells. CD8+ T cells and NK cells appeared to be relatively resistant to high-dose of radiation. This change was also accompanied by the reduction of T- and B- progenitor cells in the bone marrow. In contrast, no significant changes of the number of CD4+ T, CD8+ T, NK, and B cells were observed in the spleen of mice exposed at low-dose-rate (0.7 m Gy/h or 3.95 mGy/h) for up to 2 Gy, suggesting that low-dose radiation does not alter cellular distribution in the spleen. Nevertheless, mice exposed to low-dose radiation exhibited elevation of VEGF, MCP-1, IL-4, Leptin, IL-3, and Tpo in the peripheral blood and slight increases in MIP-2, RANTES, and IL-2 in the spleen. This suggests that chronic γ-radiation can stimulate immune function without causing damage to the immune components of the body. Taken together, these data indicate hormesis of low-dose radiation, which could be attributed to the stimulation of immune function. Dose rate rather than total

  11. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  12. Braquiterapia de alta taxa de dose no Brasil High-dose rate brachytherapy in Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2004-10-01

    Full Text Available A braquiterapia de alta taxa de dose foi introduzida em nosso meio em janeiro de 1991. Desde então, houve uma mudança significativa na abordagem das neoplasias malignas em relação às vantagens do novo método, e também resolução da demanda reprimida de braquiterapia para as neoplasias ginecológicas. Nos primeiros dez anos de atividade, o Brasil tratou, em 31 serviços, 26.436 pacientes com braquiterapia, sendo mais de 50% das pacientes portadoras de neoplasias do colo uterino. Este estudo mostra o número e o perfil de pacientes tratados com esse método e a sua distribuição no território nacional, deixando explícito o benefício da braquiterapia de alta taxa de dose para o Brasil.High-dose rate brachytherapy was first introduced in Brazil in January 1991. Significant changes in the management of malignant neoplasms were observed since utilization of high-dose rate brachytherapy. The high number of gynecological patients awaiting for brachytherapy also decreased during this period. In the first ten years 26,436 patients were treated with high-dose rate brachytherapy. More than 50% of these patients presented neoplasms of the uterine cervix. In this study we present the number and profile of the patients treated with high-dose rate brachytherapy as well as the distribution of these patients in the Brazilian territory, proving the benefit of the use of high-dose rate brachytherapy in Brazil.

  13. SU-F-T-667: Development and Validation of Dose Calculation for An Open-Source KV Treatment Planning System for Small Animal Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Prajapati, S [M D Anderson Cancer Center, Houston, TX (United States); Mo, X; Bednarz, B; Lawless, M; Hammer, C; Jeraj, R; Mackie, T [University of Wisconsin- Madison, Madison, WI (United States); Flynn, R [University of Iowa Hospitals and Clinics, Iowa City, IA (United States); Westerly, D [University of Colorado Denver, Aurora, CO (United States)

    2016-06-15

    Purpose: An open-source, convolution/superposition based kV-treatment planning system(TPS) was developed for small animal radiotherapy from previously existed in-house MV-TPS. It is flexible and applicable to both step and shoot and helical tomotherapy treatment delivery. For initial commissioning process, the dose calculation from kV-TPS was compared with measurements and Monte Carlo(MC) simulations. Methods: High resolution, low energy kernels were simulated using EGSnrc user code EDKnrc, which was used as an input in kV-TPS together with MC-simulated x-ray beam spectrum. The Blue Water™ homogeneous phantom (with film inserts) and heterogeneous phantom (with film and TLD inserts) were fabricated. Phantom was placed at 100cm SSD, and was irradiated with 250 kVp beam for 10mins with 1.1cm × 1.1cm open field (at 100cm) created by newly designed binary micro-MLC assembly positioned at 90cm SSD. Gafchromic™ EBT3 film was calibrated in-phantom following AAPM TG-61 guidelines, and were used for measurement at 5 different depths in phantom. Calibrated TLD-100s were obtained from ADCL. EGS and MNCP5 simulation were used to model experimental irradiation set up calculation of dose in phantom. Results: Using the homogeneous phantom, dose difference between film and kV-TPS was calculated: mean(x)=0.9%; maximum difference(MD)=3.1%; standard deviation(σ)=1.1%. Dose difference between MCNP5 and kV-TPS was: x=1.5%; MD=4.6%; σ=1.9%. Dose difference between EGS and kV-TPS was: x=0.8%; MD=1.9%; σ=0.8%. Using the heterogeneous phantom, dose difference between film and kV-TPS was: x=2.6%; MD=3%; σ=1.1%; and dose difference between TLD and kV-TPS was: x=2.9%; MD=6.4%; σ=2.5%. Conclusion: The inhouse, open-source kV-TPS dose calculation system was comparable within 5% of measurements and MC simulations in both homogeneous and heterogeneous phantoms. The dose calculation system of the kV-TPS is validated as a part of initial commissioning process for small animal radiotherapy

  14. Large animal normal tissue tolerance with boron neutron capture.

    Science.gov (United States)

    Gavin, P R; Kraft, S L; DeHaan, C E; Swartz, C D; Griebenow, M L

    1994-03-30

    Normal tissue tolerance of boron neutron capture irradiation using borocaptate sodium (NA2B12H11SH) in an epithermal neutron beam was studied. Large retriever-type dogs were used and the irradiations were performed by single dose, 5 x 10 dorsal portal. Fourteen dogs were irradiated with the epithermal neutron beam alone and 35 dogs were irradiated following intravenous administration of borocaptate sodium. Total body irradiation effect could be seen from the decreased leukocytes and platelets following irradiation. Most values returned to normal within 40 days postirradiation. Severe dermal necrosis occurred in animals given 15 Gy epithermal neutrons alone and in animals irradiated to a total peak physical dose greater than 64 Gy in animals following borocaptate sodium infusion. Lethal brain necrosis was seen in animals receiving between 27 and 39 Gy. Lethal brain necrosis occurred at 22-36 weeks postirradiation. A total peak physical dose of approximately 27 Gy and blood-boron concentrations of 25-50 ppm resulted in abnormal magnetic resonance imaging results in 6 months postexamination. Seven of eight of these animals remained normal and the lesions were not detected at the 12-month postirradiation examination. The bimodal therapy presents a complex challenge in attempting to achieve dose response assays. The resultant total radiation dose is a composite of low and high LET components. The short track length of the boron fission fragments and the geometric effect of the vessels causes much of the intravascular dose to miss the presumed critical target of the endothelial cells. The results indicate a large dose-sparing effect from the boron capture reactions within the blood.

  15. Large animal normal tissue tolerance with boron neutron capture

    International Nuclear Information System (INIS)

    Gavin, P.R.; Swartz, C.D.; Kraft, S.L.; Briebenow, M.L.; DeHaan, C.E.

    1994-01-01

    Normal tissue tolerance of boron neutron capture irradiation using borocaptate sodium (NA 2 B 12 H 11 SH) in an epithermal neutron beam was studied. Large retriever-type dogs were used and the irradiations were performed by single dose, 5 x 10 dorsal portal. Fourteen dogs were irradiated with the epithermal neutron beam alone and 35 dogs were irradiated following intravenous administration of borocaptate sodium. Total body irradiation effect could be seen from the decreased leukocytes and platelets following irradiation. Most values returned to normal within 40 days postirradiation. Severe dermal necrosis occurred in animals given 15 Gy epithermal neutrons alone and in animals irradiated to a total peak physical dose greater than 64 Gy in animals following borocaptate sodium infusion. Lethal brain necrosis was seen in animals receiving between 27 and 39 Gy. Lethal brain necrosis occurred at 22-36 weeks postirradiation. A total peak physical dose of approximately 27 Gy and blood-boron concentrations of 25-50 ppm resulted in abnormal magnetic resonance imaging results in 6 months postexamination. Seven of eight of these animals remained normal and the lesions were not detected at the 12-month postirradiation examination. The bimodal therapy presents a complex challenge in attempting to achieve dose response assays. The resultant total radiation dose is a composite of low and high LET components. The short track length of the boron fission fragments and the geometric effect of the vessels causes much of the intravascular dose to miss the presumed critical target of the endothelial cells. The results indicate a large dose-sparing effect from the boron capture reactions within the blood. 23 refs., 6 figs., 2 tabs

  16. High dose methylprednisolone in the management of acute spinal cord injury - a systematic review from a clinical perspective.

    Science.gov (United States)

    Short, D J; El Masry, W S; Jones, P W

    2000-05-01

    Systematic literature review for primary data using predefined inclusion, exclusion and validity criteria. Primary outcome measure was standardised neurological examination or neurological function. Secondary outcomes; acute mortality, early morbidity. To access the literature available to clinicians systematically and evaluate the evidence for an effect of high dose methylprednisolone (MPSS) on neurological improvement following acute spinal cord injury (ACSI). Information retrieval was based on Medline search (1966 through December 1999) using the strategy 'spinal cord injury' and 'methylprednisolone' (or 'dexamethasone') with no other restrictions. Primary data publications using high dose steroids given within 12 h following spinal cord injury and reporting outcome measures separately for steroid and non-steroid treated groups were selected. Evaluation followed the guides of Guyatt et al7 (for the Evidence Based Working Group in Canada). Studies with questionable validity were excluded. Level of evidence and treatment recommendation utilised the Canadian Task Force on the Periodic Health Examination criteria.6 Experimental spinal cord injury studies on larger animals were included; small mammal experiments were considered beyond evaluation. Three clinical trials and six cohort study publications were found to satisfy the review criteria. The evidence they provide supports 'the recommendation that the manoeuvre (high dose methylpredisolone) be excluded from consideration as an intervention for the condition'10 (acute spinal cord injury). Twelve larger animal publications were detailed. Validity and the functional significance of results was of concern in many. The weight of evidence lay with those studies demonstrating no definite effect of MPSS on functional outcome. In cat experiments with higher level cord damage, deaths in the MPSS treated groups were notable. The evidence produced by this systematic review does not support the use of high dose

  17. Efeitos das isoflavonas em altas doses sobre o útero da rata Effects of high-dose isoflavones on rat uterus

    Directory of Open Access Journals (Sweden)

    Adriana Aparecida Ferraz Carbonel

    2011-10-01

    Full Text Available OBJETIVO: Avaliar o efeito de altas doses de isoflavonas no útero de ratas adultas castradas. MÉTODOS: Ratas virgens ovariectomizadas (n = 40 foram tratadas por 30 dias consecutivos com veículo (GCtrl ou genisteína nas concentrações 42 (GES42, 125 (GES125 e 250 (GES250 µg/g de peso corporal ao dia. O extrato de soja e o veículo (propilenoglicol foram administrados por gavagem. Ao final do experimento, foi realizada dosagem sérica de 17 β-estradiol e progesterona, avaliou-se o peso dos animais e dos úteros e foi feito exame colpocitológico. Fragmentos do terço médio dos cornos uterinos foram fixados em formol a 10% e processados para inclusão em parafina para estudo histológico. Cortes de 5 µm de espessura foram corados pelo HE e destinados a estudo em microscopia de luz. Analisou-se a histomorfologia do endométrio, área endometrial, número e área ocupada pelas glândulas, assim como a concentração de eosinófilos presentes na lâmina própria. Os dados numéricos obtidos foram submetidos à análise de variância complementada pelo teste de Tukey-Kramer (p GES125 do que nos outros grupos (GES250 > GES125 > GES42 = GCtrl; p OBJECTIVE: To evaluate the effects of high-dose isoflavones on the uterus of castrated adult rats. METHODS: Adult, ovariectomized virgin rats (n = 40 were treated by gavage during 30 consecutive days with vehicle (propylene glycol, group GCtrl or different doses of genistein: 42 (group GES42, 125 (GES125, or 250 (GES250 µg/g body weight per day. Animals were killed, weighed, vaginal and uterine samples were taken for cytologic evaluation, and serum levels of 17 β-estradiol and progesterone were determined. The middle third of the uterine horns was dissected, fixed in 10% formaldehyde and processed for paraffin inclusion; 5-µm thick sections were obtained and stained with HE for further histological study under light microscopy. The endometrial morphology and area, number and area of glands, and number

  18. The ultrastructural changes in the liver cells induced by high doses of Benzodiazepine Tranquilizing drugs: An experimental transmission electron microscopic study on male guinea pigs

    International Nuclear Information System (INIS)

    Bisher, Ameen S. Ahmad

    2008-01-01

    Benzodiazepines are tranquilizing psychotropic drugs. Unfortunately, despite their therapeutic benefits, they are illegally consumed in high doses by some addicts to reach a sedative, exhilarative and euphoria state similar to that produced by narcotic substances. The present study, using transmission electron microscope on male guinea pigs, aims to investigate the potential ultrastructural changes in the liver cells induced by the high doses of Benzodiazepines. Animals in three treated groups administrated a daily combined dose consisted of (10mg Alprazolam with 10mg Diazepam/day/animal) for three different treatment periods: 7, 15, and 25 days. The ultrastructural examination of the hepatocytes of the animals treated for 15 days showed limited changes in the form of marginal heterochromatine accompanied with marginal nucleoli enlargement. On the other hand, severe ultrastructural damages are observed in the animals treated for 25 days, which appeared in the following various patterns: fatty degeneration of the hepatocytes as indicated by the accumulation of large number of lipid droplets in the cytoplasm, marked nuclear atrophy in some necrotic hepatocytes, massive nuclear degeneration in other hepatocytes, mitochondrial damages in the form of cristea destruction accompanied with abnormal oval shape, massive lysis of the cytoplasmic organelles with severe plasma membrane rupture. In conclusion, the observed ultrastructural damages in the present study may refer to the potential hepatotoxic effects of the high dose of Benzodiazepins. It is recommended that much more official restrictions should be applied on the pharmacies sector to prevent any illegal selling of these drugs in order to prevent abusers from obtaining them, as unfortunately in some developing countries the illegal selling of these drugs is known to occur due to the absence of official control. (author)

  19. Animated Cell Biology: A Quick and Easy Method for Making Effective, High-Quality Teaching Animations

    Science.gov (United States)

    O'Day, Danton H.

    2006-01-01

    There is accumulating evidence that animations aid learning of dynamic concepts in cell biology. However, existing animation packages are expensive and difficult to learn, and the subsequent production of even short animations can take weeks to months. Here I outline the principles and sequence of steps for producing high-quality PowerPoint…

  20. Assessment of fetal activity concentration and fetal dose for selected radionuclides based on animal and human data

    International Nuclear Information System (INIS)

    Roedler, H.D.

    1987-01-01

    Biokinetic data of selected radionuclide compounds from investigations in man and animal were taken from literature references with the purpose to provide a basis for a comparative assessment of fetal and adult radiation doses after intake or administration of radionuclides. The following ratios of fetal to adult doses were derived from human data: 0.5 for caesium 137 and total body, 2.3 for iron 59 and liver, 0.06 - 0.3 - 1.1 for iodine 131 and thyroid, and 0.1 - 0.3 for strontium 90 and bone. The ratios of activity concentrations in fetal and adult tissues are of considerable variability - up to three orders of magnitude. Further studies on fetal and adult biokinetics specifically designed for comparative dose assessment are indispensable. 106 refs.; 6 tabs

  1. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  2. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  3. Low dose radiation enhance the anti-tumor effect of high dose radiation on human glioma cell U251

    International Nuclear Information System (INIS)

    Wang Chang; Wang Guanjun; Tan Yehui; Jiang Hongyu; Li Wei

    2008-01-01

    Objective: To detect the effect on the growth of human glioma cell U251 induced by low dose irradiation and low dose irradiation combined with large dose irradiation. Methods: Human glioma cell line U251 and nude mice carried with human glioma were used. The tumor cells and the mice were treated with low dose, high dose, and low dose combined high dose radiation. Cells growth curve, MTT and flow cytometry were used to detect the proliferation, cell cycle and apoptosis of the cells; and the tumor inhibition rate was used to assess the growth of tumor in vivo. Results: After low dose irradiation, there was no difference between experimental group and control group in cell count, MTT and flow cytometry. Single high dose group and low dose combined high dose group both show significantly the suppressing effect on tumor cells, the apoptosis increased and there was cell cycle blocked in G 2 period, but there was no difference between two groups. In vivo apparent anti-tumor effect in high dose radiation group and the combining group was observed, and that was more significant in the combining group; the prior low dose radiation alleviated the injury of hematological system. There was no difference between single low dose radiation group and control. Conclusions: There is no significant effect on human glioma cell induced by low dose radiation, and low dose radiation could not induce adaptive response. But in vivo experience, low dose radiation could enhance the anti-tumor effect of high dose radiation and alleviated the injury of hematological system. (authors)

  4. Dose Response of MARV/Angola Infection in Cynomolgus Macaques following IM or Aerosol Exposure

    Science.gov (United States)

    Johnston, Sara C.; Lin, Kenny L.; Twenhafel, Nancy A.; Raymond, Jo Lynne W.; Shamblin, Joshua D.; Wollen, Suzanne E.; Wlazlowski, Carly B.; Wilkinson, Eric R.; Botto, Miriam A.; Goff, Arthur J.

    2015-01-01

    Marburg virus infection in humans causes a hemorrhagic disease with a high case fatality rate. Countermeasure development requires the use of well-characterized animal models that mimic human disease. To further characterize the cynomolgus macaque model of MARV/Angola, two independent dose response studies were performed using the intramuscular or aerosol routes of exposure. All animals succumbed at the lowest target dose; therefore, a dose effect could not be determined. For intramuscular-exposed animals, 100 PFU was the first target dose that was not significantly different than higher target doses in terms of time to disposition, clinical pathology, and histopathology. Although a significant difference was not observed between aerosol-exposed animals in the 10 PFU and 100 PFU target dose groups, 100 PFU was determined to be the lowest target dose that could be consistently obtained and accurately titrated in aerosol studies. PMID:26413900

  5. Dose Response of MARV/Angola Infection in Cynomolgus Macaques following IM or Aerosol Exposure.

    Directory of Open Access Journals (Sweden)

    Sara C Johnston

    Full Text Available Marburg virus infection in humans causes a hemorrhagic disease with a high case fatality rate. Countermeasure development requires the use of well-characterized animal models that mimic human disease. To further characterize the cynomolgus macaque model of MARV/Angola, two independent dose response studies were performed using the intramuscular or aerosol routes of exposure. All animals succumbed at the lowest target dose; therefore, a dose effect could not be determined. For intramuscular-exposed animals, 100 PFU was the first target dose that was not significantly different than higher target doses in terms of time to disposition, clinical pathology, and histopathology. Although a significant difference was not observed between aerosol-exposed animals in the 10 PFU and 100 PFU target dose groups, 100 PFU was determined to be the lowest target dose that could be consistently obtained and accurately titrated in aerosol studies.

  6. First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Daniel H.; Lundstroem, Ulf; Burvall, Anna; Hertz, Hans M. [Department of Applied Physics, KTH Royal Institute of Technology/Albanova, 10691 Stockholm (Sweden); Westermark, Ulrica K.; Arsenian Henriksson, Marie [Department of Microbiology, Tumor and Cell Biology (MTC), Karolinska Institutet, 17177 Stockholm (Sweden)

    2013-02-15

    Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

  7. NIST high-dose calibration services

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1989-01-01

    There is a need for the standardization of high-dose measurements used in the radiation-processing industry in order to provide assured traceability to national standards. NIST provides dosimetry calibration services to this industry. One of these services involves administration of known absorbed doses of gamma rays to customer-supplied dosimeters. The dosimeters are packaged to provide electron equilibrium conditions and are irradiated in a standard 60 Co calibration facility; this provides a calibration of that batch of dosimeters. Another service consists of supplying to a customer calibrated transfer dosimeters for irradiation with the customer's radiation source. The irradiated transfer dosimeters are then returned to NIST for analysis; the results are reported to the customer, providing a calibration of the dose rate of the customer's source. (orig.)

  8. Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times.

    Science.gov (United States)

    De Lin, Ming; Toncheva, Greta; Nguyen, Giao; Kim, Sangroh; Anderson-Evans, Colin; Johnson, G Allan; Yoshizumi, Terry T

    2008-08-01

    Digital subtraction angiography (DSA) X-ray imaging for small animals can be used for functional phenotyping given its ability to capture rapid physiological changes at high spatial and temporal resolution. The higher temporal and spatial requirements for small-animal imaging drive the need for short, high-flux X-ray pulses. However, high doses of ionizing radiation can affect the physiology. The purpose of this study was to verify and apply metal oxide semiconductor field effect transistor (MOSFET) technology to dosimetry for small-animal diagnostic imaging. A tungsten anode X-ray source was used to expose a tissue-equivalent mouse phantom. Dose measurements were made on the phantom surface and interior. The MOSFETs were verified with thermoluminescence dosimeters (TLDs). Bland-Altman analysis showed that the MOSFET results agreed with the TLD results (bias, 0.0625). Using typical small animal DSA scan parameters, the dose ranged from 0.7 to 2.2 cGy. Application of the MOSFETs in the small animal environment provided two main benefits: (1) the availability of results in near real-time instead of the hours needed for TLD processes and (2) the ability to support multiple exposures with different X-ray techniques (various of kVp, mA and ms) using the same MOSFET. This MOSFET technology has proven to be a fast, reliable small animal dosimetry method for DSA imaging and is a good system for dose monitoring for serial and gene expression studies.

  9. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    International Nuclear Information System (INIS)

    Oliveira, Jetro Pereira de; Batista, Delano Valdivino Santos; Bardella, Lucia Helena; Carvalho, Arnaldo Rangel

    2009-01-01

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  10. Plutonium dose-effect relationship

    International Nuclear Information System (INIS)

    Matsuoka, Osamu

    1976-01-01

    Dose in internal exposure to Pu was investigated, and dose-effect relationship was discussed. Dose-effect relationship in internal exposure was investigated by means of two methods, which were relationship between dose and its effect (relationship between μ Ci/Kg and its effect), and exposure dose and its effects (rad-effect), and merits and demerits of two methods were mentioned. Problems in a indication method such as mean dose were discussed with respect to the dose in skeleton, the liver and the lung. Pu-induced osteosarcoma in mice rats, and beagles was described, and differences in its induction between animals were discussed. Pulmonary neoplasma induced by 239 PuO 2 inhalation in beagles was reported, and description was made as to differences in induction of lung cancer between animals when Pu was inhaled and was taken into the lung. A theoretical and experimental study of a extrapolation of the results of the animal experiment using Pu to human cases is necessary. (Serizawa, K.)

  11. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  12. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  13. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  14. Investigation of polymer composite for high dose dosimetry

    International Nuclear Information System (INIS)

    Pereira, E.L.M.; Batista, A.S.M.; Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H.

    2017-01-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO 2 ) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm -1 and 1730 cm -1 can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm -1 and 1730 cm -1 whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  15. Statistical behavior of high doses in medical radiodiagnosis

    International Nuclear Information System (INIS)

    Barboza, Adriana Elisa

    2014-01-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  16. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  17. High resolution propagation-based imaging system for in vivo dynamic computed tomography of lungs in small animals

    Science.gov (United States)

    Preissner, M.; Murrie, R. P.; Pinar, I.; Werdiger, F.; Carnibella, R. P.; Zosky, G. R.; Fouras, A.; Dubsky, S.

    2018-04-01

    We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution of slightly below 50 μm at imaging rates of 30 Hz, and the ability to quantify material density differences of at least 3%. We benchmark our system against existing small animal pre-clinical CT scanners using a quality factor that combines spatial resolution, image noise, dose and scan time. In vivo 4DCT images obtained on our system demonstrate resolution of important features such as blood vessels and small airways, of which the smallest discernible were measured as 55–60 μm in cross section. Quantitative analysis of the images demonstrate regional differences in ventilation between injured and healthy lungs.

  18. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  19. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  20. Mechanism of Action for Anti-radiation Vaccine in Reducing the Biological Impact of High-dose Gamma Irradiation

    Science.gov (United States)

    Maliev, Vladislav; Popov, Dmitri; Jones, Jeffrey A.; Casey, Rachael C.

    2007-01-01

    Ionizing radiation is a major health risk of long-term space travel, the biological consequences of which include genetic and oxidative damage. In this study, we propose an original mechanism by which high doses of ionizing radiation induce acute toxicity. We identified biological components that appear in the lymphatic vessels shortly after gamma irradiation. These radiation-induced toxins, which we have named specific radiation determinants (SRD), were generated in the irradiated tissues and then collected and circulated throughout the body via the lymph circulation and bloodstream. Depending on the type of SRD elicited, different syndromes of acute radiation sickness (ARS) were expressed. The SRDs were developed into a vaccine used to confer active immunity against acute radiation toxicity in immunologically naive animals. Animals that were pretreated with SRDs exhibited resistance to lethal doses of gamma radiation, as measured by increased survival times and survival rates. In comparison, untreated animals that were exposed to similar large doses of gamma radiation developed acute radiation sickness and died within days. This phenomenon was observed in a number of mammalian species. Initial analysis of the biochemical characteristics indicated that the SRDs were large molecular weight (200-250 kDa) molecules that were comprised of a mixture of protein, lipid, carbohydrate, and mineral. Further analysis is required to further identify the SRD molecules and the biological mechanism by which the mediate the toxicity associated with acute radiation sickness. By doing so, we may develop an effective specific immunoprophylaxis as a countermeasure against the acute effects of ionizing radiation.

  1. Pharmacogenetics and Pharmacokinetics in high-dose alkylating chemotherapy

    NARCIS (Netherlands)

    Ekhart, G.C. (Corine)

    2008-01-01

    High-dose chemotherapy in combination with peripheral blood progenitor cell transplantation has been developed as a possible curative treatment modality in several solid tumours. A frequently used high-dose regimen in the Netherlands is the CTC regimen, which is a 4-day course of cyclophosphamide,

  2. Establishment and verification of dose-response curve of chromosomal aberrations after exposure to very high dose γ-ray

    International Nuclear Information System (INIS)

    Chen Ying; Luo Yisheng; Cao Zhenshan; Liu Xiulin

    2006-01-01

    To estimate accurately biological dose of the victims exposed to high dose, the dose-response curves of chromosome aberration induced by 6-22 Gy 60 Co γ-ray were established. Human peripheral blood in vitro was irradiated, then lymphocytes were concentrated, cultured 52h, 68h and 72h and harvested. The frequencies of dicentrics (multi-centrics) and rings were counted and compared between different culture times. The dose-response curves and equations were established, as well as verified with high dose exposure accidents. The experiment showed that the culture time should be prolonged properly after high dose exposure, and no significant differences were observed between 52-72h culture. The dose-response curve of 6-22 Gy fitted to linear-square model Y=-2.269 + 0.776D - 7.868 x 10 -3 D 2 and is reliable through verification of the accident dose estimations. In this study, the dose-response curve and equation of chromosome dic + r after 6-22 Gy high dose irradiation were established firstly, and exact dose estimation can be achieved according to it. (authors)

  3. Nonlinear model of high-dose implantation

    International Nuclear Information System (INIS)

    Danilyuk, A.

    2001-01-01

    The models of high-dose implantation, using the distribution functions, are relatively simple. However, they must take into account the variation of the function of distribution of the implanted ions with increasing dose [1-4]. This variation takes place owing to the fact that the increase of the concentration of the implanted ions results in a change of the properties of the target. High-dose implantation is accompanied by sputtering, volume growth, diffusion, generation of defects, formation of new phases, etc. The variation of the distribution function is determined by many factors and is not known in advance. The variation within the framework of these models [1-4] is taken into account in advance by the introduction of intuitive assumptions on the basis of implicit considerations. Therefore, these attempts should be regarded as incorrect. The model prepared here makes it possible to take into account the sputtering of the target, volume growth and additional declaration on the implanted ions. Without any assumptions in relation to the variation of the distribution function with increasing dose. In our model it is assumed that the type of distribution function for small doses in a pure target substance is the same as in substances with implanted ions. A second assumption relates to the type of the distribution function valid for small doses in the given substances. These functions are determined as a result of a large number of theoretical and experimental investigations and are well-known at the present time. They include the symmetric and nonsymmetric Gauss distribution, the Pearson distribution, and others. We examine implantation with small doses of up to 10 14 - 10 15 cm -2 when the accurately known distribution is valid

  4. Radiobiological equivalent of low/high dose rate brachytherapy and evaluation of tumor and normal responses to the dose.

    Science.gov (United States)

    Manimaran, S

    2007-06-01

    The aim of this study was to compare the biological equivalent of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy in terms of the more recent linear quadratic (LQ) model, which leads to theoretical estimation of biological equivalence. One of the key features of the LQ model is that it allows a more systematic radiobiological comparison between different types of treatment because the main parameters alpha/beta and micro are tissue-specific. Such comparisons also allow assessment of the likely change in the therapeutic ratio when switching between LDR and HDR treatments. The main application of LQ methodology, which focuses on by increasing the availability of remote afterloading units, has been to design fractionated HDR treatments that can replace existing LDR techniques. In this study, with LDR treatments (39 Gy in 48 h) equivalent to 11 fractions of HDR irradiation at the experimental level, there are increasing reports of reproducible animal models that may be used to investigate the biological basis of brachytherapy and to help confirm theoretical predictions. This is a timely development owing to the nonavailability of sufficient retrospective patient data analysis. It appears that HDR brachytherapy is likely to be a viable alternative to LDR only if it is delivered without a prohibitively large number of fractions (e.g., fewer than 11). With increased scientific understanding and technological capability, the prospect of a dose equivalent to HDR brachytherapy will allow greater utilization of the concepts discussed in this article.

  5. High-dose gadolinium-enhanced MRI for diagnosis of meningeal metastases

    International Nuclear Information System (INIS)

    Kallmes, D.F.; Gray, L.; Glass, J.P.

    1998-01-01

    We compared high-dose (0.3 mmol/kg) and standard-dose (0.1 mmol/kg) gadolinium-enhanced MRI for diagnosis of meningeal metastases in 12 patients with suspected meningeal metastases. They were imaged with both standard-dose and high-dose gadolinium. All patients with abnormal meningeal enhancement underwent at least one lumbar puncture for cerebrospinal fluid (CSF) cytology, while patients with normal meningeal enhancement were followed clinically. All patients with negative CSF cytology also were followed clinically. A single observer reviewed all the images, with specific attention to the enhancement pattern of the meninges. Abnormal leptomeningeal enhancement was present in three cases, and abnormal pachymeningeal enhancement in three other patients. All of these patients had abnormal CSF analyses. In two of the three cases of abnormal leptomeningeal enhancement the disease was more evident on high-dose than on standard-dose imaging; in one case the abnormal enhancement was visible only on high-dose imaging. In one of the three cases with abnormal pachymeningeal enhancement, the disease was evident prospectively only with high-dose imaging. (orig.)

  6. Evaluation of doses from radiodiagnostic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners; Avaliacao das doses resultantes de procedimentos radiodiagnosticos realizados em medicina veterinaria e avaliacao das doses secundarias de radiacao espalhada no corpo clinico e nos proprietarios dos animais

    Energy Technology Data Exchange (ETDEWEB)

    Veneziani, Glauco Rogerio

    2012-07-01

    The primary goal in veterinary radiography is to produce radiographs of diagnostic quality on the first attempt. This goal serves three purposes: (1) to decrease radiation exposure to the patient and veterinary personnel; (2) to decrease the cost of the study for the client; and (3) to produce diagnostic data for rapid interpretation and treatment of the patient. This work aimed to determine the doses in dogs submitted to chest and abdomen X rays using the technique of thermoluminescence (TL) dosimetry. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO{sub 4}:Dy) and lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti). The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pet's owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics. (author)

  7. Investigation of polymer composite for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, E.L.M.; Batista, A.S.M., E-mail: adriananuclear@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO{sub 2}) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm{sup -1} and 1730 cm{sup -1} can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm{sup -1} and 1730 cm{sup -1} whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  8. Methodology of high dose research in medical radiodiagnostic

    International Nuclear Information System (INIS)

    Barboza, Adriana E.; Martins, Cintia P. de S.

    2013-01-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations

  9. High-dose preoperative radiation for cancer of the rectum: Impact of radiation dose on patterns of failure and survival

    International Nuclear Information System (INIS)

    Ahmad, N.R.; Mohiuddin, M.; Marks, G.

    1993-01-01

    A variety of dose-time schedules are currently used for preoperative radiation therapy of rectal cancer. An analysis of patients treated with high-dose preoperative radiation therapy was undertaken to determine the influence of radiation dose on the patterns of failure, survival, and complications. Two hundred seventy-five patients with localized rectal cancer were treated with high-dose preoperative radiation therapy. One hundred fifty-six patients received 45 Gy (low-dose group). Since 1985, 119 patients with clinically unfavorable cancers were given a higher dose, 55 Gy using a shrinking field technique (high-dose group). All patients underwent curative resection. Median follow-up was 66 months in the low-dose group and 28 months in the high-dose group. Patterns of failure, survival, and complications were analyzed as a function of radiation dose. Fourteen percent of the total group developed a local recurrence; 20% in the low-dose group as compared with 6% in the high-dose group. The actuarial local recurrence rate at 5 years was 20% for the low-dose group and 8% for the high-dose group, and approached statistical significance with p = .057. For tethered/fixed tumors the actuarial local recurrence rates at 5 years were 28% and 9%, respectively, with p = .05. Similarly, for low-lying tumors (less than 6 cm from the anorectal junction) the rates were 24% and 9%, respectively, with p = .04. The actuarial rate of distant metastasis was 28% in the low-dose group and 20% in the high-dose group and was not significantly different. Overall actuarial 5-year survival for the total group of patients was 66%. No significant difference in survival was observed between the two groups, despite the higher proportion of unfavorable cancers in the high-dose group. The incidence of complications was 2%, equally distributed between the two groups. High-dose preoperative radiation therapy for rectal cancer results in excellent local control rates. 27 refs., 2 figs., 8 tabs

  10. Acute renal failure in high dose carboplatin chemotherapy

    NARCIS (Netherlands)

    Frenkel, J.; Kool, G.; de Kraker, J.

    1995-01-01

    Carboplatin has been reported to cause acute renal failure when administered in high doses to adult patients. We report a 4 1/2-year-old girl who was treated with high-dose carboplatin for metastatic parameningeal embryonal rhabdomyosarcoma. Acute renal failure developed followed by a slow partial

  11. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  12. Effects of two different high doses of irradiation on antioxidant system in the liver of guinea pigs.

    Science.gov (United States)

    Guney, Yildiz; Bukan, Neslihan; Dizman, Aysen; Hicsonmez, Ayse; Bilgihan, Ayse

    2004-03-01

    To examine the state of the oxidant-antioxidant system in the liver of guinea pig caused by high doses of ionizing radiation in the early period. The research was carried out on guinea pigs irradiated with the doses of 8 Gy (group 2) or 15 Gy (group 3) (single dose/whole body) in comparison with control group (group 1). The levels of thiobarbituric acid reactive substances (TBARS) and glutathione (GSH), the activities of superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GSH-Px) and the levels of selenium in the liver were measured. TBARS levels in the irradiated animals were markedly higher than those in controls. In group 3, GSH levels and GSH-Px activity were significantly increased while activity of SOD and CAT were significantly decreased compared to groups 1 and 2. Liver selenium levels were not influenced by irradiation. The data have shown that gamma-irradiation at the doses of 8 Gy or 15 Gy results in significant increase in free radical formation while antioxidant enzymes were affected only at a dose of 15 Gy.

  13. Bluetongue Disabled Infectious Single Animal (DISA) vaccine: Studies on the optimal route and dose in sheep.

    Science.gov (United States)

    van Rijn, Piet A; Daus, Franz J; Maris-Veldhuis, Mieke A; Feenstra, Femke; van Gennip, René G P

    2017-01-05

    Bluetongue (BT) is a disease of ruminants caused by bluetongue virus (BTV) transmitted by biting midges of the Culicoides genus. Outbreaks have been controlled successfully by vaccination, however, currently available BT vaccines have several shortcomings. Recently, we have developed BT Disabled Infectious Single Animal (DISA) vaccines based on live-attenuated BTV without expression of dispensable non-structural NS3/NS3a protein. DISA vaccines are non-pathogenic replicating vaccines, do not cause viremia, enable DIVA and are highly protective. NS3/NS3a protein is involved in virus release, cytopathogenic effect and suppression of Interferon-I induction, suggesting that the vaccination route can be of importance. A standardized dose of DISA vaccine for serotype 8 has successfully been tested by subcutaneous vaccination. We show that 10 and 100times dilutions of this previously tested dose did not reduce the VP7 humoral response. Further, the vaccination route of DISA vaccine strongly determined the induction of VP7 directed antibodies (Abs). Intravenous vaccination induced high and prolonged humoral response but is not practical in field situations. VP7 seroconversion was stronger by intramuscular vaccination than by subcutaneous vaccination. For both vaccination routes and for two different DISA vaccine backbones, IgM Abs were rapidly induced but declined after 14days post vaccination (dpv), whereas the IgG response was slower. Interestingly, intramuscular vaccination resulted in an initial peak followed by a decline up to 21dpv and then increased again. This second increase is a steady and continuous increase of IgG Abs. These results indicate that intramuscular vaccination is the optimal route. The protective dose of DISA vaccine has not been determined yet, but it is expected to be significantly lower than of currently used BT vaccines. Therefore, in addition to the advantages of improved safety and DIVA compatibility, the novel DISA vaccines will be cost

  14. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  15. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  16. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  17. Biological changes in experimental animals after irradiation with sublethal doses

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Dae Seong; Park, Yong Dae; Jin, Chang Hyun; Byun, Myung Woo; Jeong, Il Yun [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2008-05-15

    The objective of the present study was to investigate general clinical aspects such as weekly body weight and blood changes, and weekly food intake in gamma-irradiated C57BL/6j male mice fed AIN-76A purified rodent diet for 14 weeks. The mice were whole-body irradiated with 0, 2, 4 and 6 Gy of gamma-rays (Gammacell 40 Exactor, {sup 137}Cs, MDS Nordion) at a dose rate of 1.8 {sub c}Gy per second. The mean body weight change of 6 Gy-irradiated mice significantly decreased when compared to that of the non-irradiated control mice. Moreover, high dose of radiation resulted in decreased levels of AST, ALT, but in increased levels of total cholersterol, triglyceride, HDL-C in mice.

  18. Update on pediatric resuscitation drugs: high dose, low dose, or no dose at all.

    Science.gov (United States)

    Sorrentino, Annalise

    2005-04-01

    Pediatric resuscitation has been a topic of discussion for years. It is difficult to keep abreast of changing recommendations, especially for busy pediatricians who do not regularly use these skills. This review will focus on the most recent guidelines for resuscitation drugs. Three specific questions will be discussed: standard dose versus high-dose epinephrine, amiodarone use, and the future of vasopressin in pediatric resuscitation. The issue of using high-dose epinephrine for cardiopulmonary resuscitation refractory to standard dose epinephrine has been a topic of debate for many years. Recently, a prospective, double-blinded study was performed to help settle the debate. These results will be reviewed and compared with previous studies. Amiodarone is a medication that was added to the pediatric resuscitation algorithms with the most recent recommendations from the American Heart Association in 2000. Its use and safety will also be discussed. Another topic that is resurfacing in resuscitation is the use of vasopressin. Its mechanism and comparisons to other agents will be highlighted, although its use in the pediatric patient has not been thoroughly studied. Pediatric resuscitation is a constantly evolving subject that is on the mind of anyone taking care of sick children. Clinicians are continually searching for the most effective methods to resuscitate children in terms of short- and long-term outcomes. It is important to be familiar with not only the agents being used but also the optimal way to use them.

  19. In vivo transcriptome modulation after low dose of high energy neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Amendola, R; Fratini, E; Piscitelli, M; Sallustio, D E [ENEA, BAS BIOTEC MED, Roma (Italy); Angelone, M; Pillon, M [ENEA, FUS TEC, Frascati (Italy); Chiani, F; Licursi, V; Negri, R [Universita La Sapienza, Roma (Italy). Dip. Biologia Cellulare e dello Sviluppo

    2007-07-01

    Complete text of publication follows. Objective: This project aims to the identification of an hypothetical transcriptome modulation of mouse peripheral blood lymphocytes and skin after exposure to high energy neutron in vivo. Positive candidate genes isolated from mice in in vivo experiments will be selected and evaluated for both radioprotection issues dealing with cosmic ray exposure, and for biomedical issues mainly for low doses and non-cancer effects. Methods: High energy neutron irradiation is performed at the ENEA Frascati, neutron generator facilities (FNG), specifically dedicated to biological samples. FNG is a linear electrostatic accelerator that produces up to 1.0 x 10{sup 11} n/s 14 MeV neutrons via the D-T nuclear reaction. The dose-rate applied for this study is of 0.7 cGy/min. The functional genomic approach has been performed on six animals for each experimental points: un-irradiated; 20 cGy, 6 hours and 24 hours delayed time after exposure. Preliminarily, a pool of total RNA is evaluated on commercial micro-arrays containing large collections of mus musculus cDNAs. Statistical filtering and functional clustering of the data is carried out using dedicated software packages. Results: Candidate genes are selected on the basis of responsiveness to 20 cGy of exposure, with a defined temporal regulation. We plan to organize a systematic screen focused on genes responding to our selection criteria, in in vivo mouse experiments, and correlate their differential expression to the human counterparts. A specific cross species database will be created with all the functional information available in standardized format (MIAME: minimal information about micro-arrays experiments). Conclusions: A lack of information on in vivo experiments is still evident for low doses exposure, especially for neutron of cosmic interest. Individual susceptibility, extensive number of animals to be processed, lack of standardization methodologies are among problems to be solved

  20. Automated Finger Spelling by Highly Realistic 3D Animation

    Science.gov (United States)

    Adamo-Villani, Nicoletta; Beni, Gerardo

    2004-01-01

    We present the design of a new 3D animation tool for self-teaching (signing and reading) finger spelling the first basic component in learning any sign language. We have designed a highly realistic hand with natural animation of the finger motions. Smoothness of motion (in real time) is achieved via programmable blending of animation segments. The…

  1. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  2. Poisoning of domestic animals with heavy metals

    Directory of Open Access Journals (Sweden)

    Velev Romel

    2009-01-01

    Full Text Available The term heavy metal refers to a metal that has a relatively high density and is toxic for animal and human organism at low concentrations. Heavy metals are natural components of the Earth's crust. They cannot be degraded or destroyed. To a small extent they enter animal organism via food, drinking water and air. Some heavy metals (e.g cooper, iron, chromium, zinc are essential in very low concentrations for the survival of all forms of life. These are described as essential trace elements. However, when they are present in greater quantities, like the heavy metals lead, cadmium and mercury which are already toxic in very low concentrations, they can cause metabolic anomalies or poisoning. Heavy metal poisoning of domestic animals could result, for instance, from drinking-water contamination, high ambient air concentrations near emission sources, or intake via the food chain. Heavy metals are dangerous because they tend to bioaccumulate in a biological organism over time. Manifestation of toxicity of individual heavy metals varies considerably, depending on dose and time of exposure, species, gender and environmental and nutritional factors. Large differences exist between the effects of a single exposure to a high concentration, and chronic exposures to lower doses. The aim of this work is to present the source of poisoning and toxicity of some heavy metals (lead, mercury, cadmium, thallium, arsenic, as well as new data about effects of those heavy metals on the health of domestic animals. .

  3. Fertility of Tall Girls Treated with High-Dose Estrogen, a Dose-Response Relationship

    NARCIS (Netherlands)

    Hendriks, A. E. J.; Drop, S. L. S.; Laven, J. S. E.; Boot, A. M.

    Context: High-dose estrogen treatment to reduce final height of tall girls increases their risk for infertility in later life. Objective: The aim was to study the effect of estrogen dose on fertility outcome of these women. Design/Setting: We conducted a retrospective cohort study of university

  4. Final Report - Epigenetics of low dose radiation effects in an animal model

    Energy Technology Data Exchange (ETDEWEB)

    Kovalchuk, Olga

    2014-10-22

    This project sought mechanistic understanding of the epigenetic response of tissues as well as the consequences of those responses, when induced by low dose irradiation in a well-established model system (mouse). Based on solid and extensive preliminary data we investigated the molecular epigenetic mechanisms of in vivo radiation responses, particularly – effects of low, occupationally relevant radiation exposures on the genome stability and adaptive response in mammalian tissues and organisms. We accumulated evidence that low dose irradiation altered epigenetic profiles and impacted radiation target organs of the exposed animals. The main long-term goal was to dissect the epigenetic basis of induction of the low dose radiation-induced genome instability and adaptive response and the specific fundamental roles of epigenetic changes (i.e. DNA methylation, histone modifications and miRNAs) in their generation. We hypothesized that changes in global and regional DNA methylation, global histone modifications and regulatory microRNAs played pivotal roles in the generation and maintenance low-dose radiation-induced genome instability and adaptive response. We predicted that epigenetic changes influenced the levels of genetic rearrangements (transposone reactivation). We hypothesized that epigenetic responses from low dose irradiation were dependent on exposure regimes, and would be greatest when organisms are exposed in a protracted/fractionated manner: fractionated exposures > acute exposures. We anticipated that the epigenetic responses were correlated with the gene expression levels. Our immediate objectives were: • To investigate the exact nature of the global and locus-specific DNA methylation changes in the LDR exposed cells and tissues and dissect their roles in adaptive response • To investigate the roles of histone modifications in the low dose radiation effects and adaptive response • To dissect the roles of regulatory microRNAs and their targets in low

  5. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  6. Teaching Veterinary Anesthesia: A Survey-Based Evaluation of Two High-Fidelity Models and Live-Animal Experience for Undergraduate Veterinary Students.

    Science.gov (United States)

    Musk, Gabrielle C; Collins, Teresa; Hosgood, Giselle

    In veterinary medical education, reduction, replacement, and refinement (the three Rs) must be considered. Three clinical skills in anesthesia were identified as challenging to students: endotracheal intubation, intravenous catheterization, and drug dose calculations. The aims of this project were to evaluate students' perception of their level of confidence in performing these three clinical skills in veterinary anesthesia, to document the extent of students' previous experience in performing these three tasks, and to describe students' emotional states during this training. Veterinary students completed a series of four surveys over the period of their pre-clinical training to evaluate the usefulness of high-fidelity models for skill acquisition in endotracheal intubation and intravenous catheterization. In addition, practice and ongoing assessment in drug dose calculations were performed. The curriculum during this period of training progressed from lectures and non-animal training, to anesthesia of pigs undergoing surgery from which they did not recover, and finally to anesthesia of dogs and cats in a neutering clinic. The level of confidence for each of the three clinical skills increased over the study period. For each skill, the number of students with no confidence decreased to zero and the proportion of students with higher levels of confidence increased. The high-fidelity models for endotracheal intubation and intravenous catheterization used to complement the live-animal teaching were considered a useful adjunct to the teaching of clinical skills in veterinary anesthesia. With practice, students became more confident performing drug dose calculations.

  7. Radiation effects of high and low doses

    International Nuclear Information System (INIS)

    El-Naggar, A.M.

    1998-01-01

    The extensive proliferation of the uses and applications of atomic and nuclear energy resulted in possible repercussions on human health. The prominent features of the health hazards that may be incurred after exposure to high and low radiation doses are discussed. The physical and biological factors involved in the sequential development of radiation health effects and the different cellular responses to radiation injury are considered. The main criteria and features of radiation effects of high and low doses are comprehensively outlined

  8. High daily doses of benzodiazepines among Quebec seniors: prevalence and correlates

    Directory of Open Access Journals (Sweden)

    Moride Yola

    2001-11-01

    Full Text Available Abstract Background Use of high daily doses of benzodiazepines is generally contraindicated for seniors. While both patient and physician factors may influence the use of high daily doses, previous research on the effect of patient factors has been extremely limited. The objectives of this study were to determine the one year prevalence of use of high daily doses of benzodiazepines, and examine physician and patient correlates of such use among Quebec community-dwelling seniors. Methods Patient information for 1423 community-dwelling Quebec seniors who participated in the Canadian Study of Health and Aging was linked to provincial health insurance administrative data bases containing detailed information on prescriptions received and prescribers. Results The standardized one year period prevalence of use of high daily doses of benzodiazepines was 7.9%. Use of high daily doses was more frequent among younger seniors and those who had reported anxiety during the previous year. Patients without cognitive impairment were more likely to receive high dose prescriptions from general practitioners, while those with cognitive impairment were more likely to receive high dose prescriptions from specialists. Conclusion High dose prescribing appears to be related to both patient and physician factors.

  9. Proximity correction of high-dosed frame with PROXECCO

    Science.gov (United States)

    Eisenmann, Hans; Waas, Thomas; Hartmann, Hans

    1994-05-01

    Usefulness of electron beam lithography is strongly related to the efficiency and quality of methods used for proximity correction. This paper addresses the above issue by proposing an extension to the new proximity correction program PROXECCO. The combination of a framing step with PROXECCO produces a pattern with a very high edge accuracy and still allows usage of the fast correction procedure. Making a frame with a higher dose imitates a fine resolution correction where the coarse part is disregarded. So after handling the high resolution effect by means of framing, an additional coarse correction is still needed. Higher doses have a higher contribution to the proximity effect. This additional proximity effect is taken into account with the help of the multi-dose input of PROXECCO. The dose of the frame is variable, depending on the deposited energy coming from backscattering of the proximity. Simulation proves the very high edge accuracy of the applied method.

  10. High-dose buprenorphine: perioperative precautions and management strategies.

    Science.gov (United States)

    Roberts, D M; Meyer-Witting, M

    2005-02-01

    Buprenorphine has been in clinical use in anaesthesia for several decades. Recently, the high-dose sublingual formulation (Subutex, Reckitt Benckiser, Slough, U.K.) has been increasingly used as maintenance therapy in opioid dependence, as an alternative to methadone and other pharmacological therapies. Buprenorphine has unique pharmacological properties making it well suited for use as a maintenance therapy in opioid dependence. However, these same properties may cause difficulty in the perioperative management of pain. Buprenorphine is a partial opioid agonist, attenuating the effects of supplemental illicit or therapeutic opioid agonists. As a result of its high receptor affinity, supplemental opioids do not readily displace buprenorphine from the opioid receptor in standard doses. High-dose buprenorphine has an extended duration of action that prolongs both of these effects. The perioperative management of patients stabilized on high-dose buprenorphine and undergoing surgery requires consideration of the likely analgesic requirements. Where possible the buprenorphine should be continued. Pain management should focus on maximizing non-opioid analgesia, local anaesthesia and non-pharmacological techniques. Where pain may not be adequately relieved by these methods, the addition of a full opioid agonist such as fentanyl or morphine at appropriate doses should be considered, accompanied by close monitoring in a high dependency unit. In situations where this regimen is unlikely to be effective, preoperative conversion to morphine or methadone may be an option. Where available, liaison with a hospital-based alcohol and drug service should always be considered.

  11. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  12. The effects of high dose and highly fractionated radiation on distraction osteogenesis in the murine mandible

    International Nuclear Information System (INIS)

    Monson, Laura A; Cavaliere, Christi M; Deshpande, Sagar S; Ayzengart, Alexander L; Buchman, Steven R

    2012-01-01

    The ability of irradiated tissue to support bony growth remains poorly defined, although there are anecdotal cases reported showing mixed results for the use of mandibular distraction osteogenesis after radiation for head and neck cancer. Many of these reports lack objective measures that would allow adequate analysis of outcomes or efficacy. The purpose of this experiment was to utilize a rat model of mandibular distraction osteogenesis after high dose and highly fractionated radiation therapy and to evaluate and quantify distracted bone formation under these conditions. Male Sprague–Dawley rats underwent 12 fractions of external beam radiation (48 Gray) of the left mandible. Following a two week recovery period, an external frame distractor was applied and gradual distraction of the mandible was performed. Tissue was harvested after a twenty-eight day consolidation period. Gross, radiologic and histological evaluations were undertaken. Those animals subjected to pre-operative radiation showed severe attenuation of bone formation including bone atrophy, incomplete bridging of the distraction gap, and gross bony defects or non-union. Although physical lengthening was achieved, the irradiated bone consistently demonstrated marked damaging effects on the normal process of distraction osteogenesis. This murine model has provided reliable evidence of the injurious effects of high dose radiation on bone repair and regeneration in distraction osteogenesis utilizing accurate and reproducible metrics. These results can now be used to assist in the development of therapies directed at mitigating the adverse consequences of radiation on the regeneration of bone and to optimize distraction osteogenesis so it can be successfully applied to post-oncologic reconstruction

  13. Pharmacokinetics of marbofloxacin in pigs after intravenous and intramuscular administration of a single dose of 8 mg/kg: dose proportionality, influence of the age of the animals and urinary elimination.

    Science.gov (United States)

    Schneider, M; Paulin, A; Dron, F; Woehrlé, F

    2014-12-01

    The pharmacokinetics of marbofloxacin in pigs were evaluated as a function of dose and animal age following intravenous and intramuscular administration of a 16% solution (Forcyl(®) ). The absolute bioavailability of marbofloxacin as well as the dose proportionality was evaluated in 27-week-old fattening pigs. Blood PK and urinary excretion of marbofloxacin were evaluated after a single intramuscular dose of 8 mg/kg in 16-week-old male pigs. An additional group of 12-week-old weaned piglets was used for the evaluation of age-related kinetics. The plasma and urine concentration of marbofloxacin was determined using a HPLC method. Pharmacokinetic parameters were calculated using noncompartmental methods. After intravenous administration in 27-week-old fattening pigs, the total body clearance was 0.065 L/h·kg. After intramuscular administration to the same animals, the mean observed Cmax was 6.30 μg/mL, and the AUCINF was 115 μg·h/mL. The absolute bioavailability was 91.5%, and dose proportionality was shown within the dose range of 4-16 mg/kg. The renal clearance was about half of the value of the total clearance. The total systemic clearance values significantly decreased as a function of age, being 0.092 L/h·kg and 0.079 L/h·kg in pigs aged 12 and 16 weeks, respectively. © 2014 The Authors. Journal of Veterinary Pharmacology and Therapeutics Published by John Wiley & Sons Ltd.

  14. Metabolism of americium-241 in dairy animals

    International Nuclear Information System (INIS)

    Sutton, W.W.; Patzer, R.G.; Mullen, A.A.; Hahn, P.B.; Potter, G.D.

    1978-10-01

    Groups of lactating cows and goats were used to examine americium-241 metabolism in dairy animals. Following either single oral or intravenous nuclide doses, samples of milk, urine, blood, and feces were taken over a 168-hr collection period and the americium concentrations were determined by gamma counting. Gastrointestinal uptake of americium by both cows and goats was estimated to be 0.014% of the respective oral doses. The cumulative percentage of oral dose transported to milk and urine was 4.4 x 10 -4 and 1.1 x 10 -3 respectively for cows and 4.4 x 10 -3 and 1.2 x 10 -3 respectively for goats. The relatively high americium concentrations noted in caprine milk following the oral doses are discussed. Plasma concentrations of americium decreased rapidly following all intravenous injections. The average percentage of injected americium transferred to milk, urine, and feces was 3, 6, and 2% respectively for cows and 2, 4, and 2% respectively for goats. In both intravenously dosed groups, approximately 30% of all americium released from the body was found in the urine during the first 24 hrs after injection. All animals were sacrificed 8 to 9 days after dosing. Bovine bone retained the greatest fraction of the administered dose followed by the liver. However, liver retained the greatest amount of americium in the goats following both oral and intravenous doses. Comparisons are presented between americium-241 and plutonium-238 transport in dairy cows

  15. High-temperature absorbed dose measurements in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.; Ardonceau, J.; Zuppiroli, L.

    1988-01-01

    Organic conductors of the tetraselenotetracene family have been tested as ''high-temperature'' absorbed dose dosimeters. They were heated up to 120 0 C and irradiated at this temperature with 1-MeV electrons in order to simulate, in a short time, a much longer γ-ray irradiation. The electric resistance increase of the crystal can be considered a good measurement of the absorbed dose in the range 10 6 Gy to a few 10 8 Gy and presumably one order of magnitude more. This dosimeter also permits on-line (in-situ) measurements of the absorbed dose without removing the sensor from the irradiation site. The respective advantages of organic and inorganic dosimeters at these temperature and dose ranges are also discussed. In this connection, we outline new, but negative, results concerning the possible use of silica as a high-temperature, high-dose dosimeter. (author)

  16. High-dose MeV electron irradiation of Si-SiO2 structures implanted with high doses Si+

    Science.gov (United States)

    Kaschieva, S.; Angelov, Ch; Dmitriev, S. N.

    2018-03-01

    The influence was studied of 22-MeV electron irradiation on Si-SiO2 structures implanted with high-fluence Si+ ions. Our earlier works demonstrated that Si redistribution is observed in Si+-ion-implanted Si-SiO2 structures (after MeV electron irradiation) only in the case when ion implantation is carried out with a higher fluence (1016 cm-2). We focused our attention on the interaction of high-dose MeV electron irradiation (6.0×1016 cm-2) with n-Si-SiO2 structures implanted with Si+ ions (fluence 5.4×1016 cm-2 of the same order magnitude). The redistribution of both oxygen and silicon atoms in the implanted Si-SiO2 samples after MeV electron irradiation was studied by Rutherford back-scattering (RBS) spectroscopy in combination with a channeling technique (RBS/C). Our results demonstrated that the redistribution of oxygen and silicon atoms in the implanted samples reaches saturation after these high doses of MeV electron irradiation. The transformation of amorphous SiO2 surface into crystalline Si nanostructures (after MeV electron irradiation) was evidenced by atomic force microscopy (AFM). Silicon nanocrystals are formed on the SiO2 surface after MeV electron irradiation. The shape and number of the Si nanocrystals on the SiO2 surface depend on the MeV electron irradiation, while their size increases with the dose. The mean Si nanocrystals height is 16-20 nm after irradiation with MeV electrons at the dose of 6.0×1016 cm-2.

  17. A novel theory of radiation damage at high doses

    International Nuclear Information System (INIS)

    Seeger, A.; Stuttgart Univ.

    1989-01-01

    Deviations of radiation damage (in the case of metals usually monitored by the residual electrical resistivity) from proportionality with the irradiation dose have so far been analysed almost exclusively in terms of extensions of models originally developed for small doses. The present theory considers the opposite limit i.e. the quasi-saturated state. It is argued that at high doses the Lueck-Sizmann effect may result in a self-organization of clusters of vacancies and self-interstitials, forming a heterogeneous froth. Possible structures of this froth and its effect on the electrical resistivity of metals are discussed. The model is shown to account for the dependence of the ''saturation resistivity'' on the nature of the irradiation as well as for several other hitherto poorly explained observations. Among them are the electrical-resistivity variation induced by high-dose irradiation with heavy ions, the amorphization of certain alloys by high-dose electron irradiation, and the occurrence of ordered arrays of stacking-fault tetrahedra after in-situ irradiations in high-voltage electron microscopes. (author)

  18. The Annual Dose for Qena Generative Population Due to Consume the Animal Products

    International Nuclear Information System (INIS)

    Harb, S.; Sahalel Din, K.; Abbady, A.; Saad, N.

    2010-01-01

    Several kinds of cattle and poultry fodder samples collected from South Valley University and Qena governorate farm, Qena, Upper Egypt were estimated for their natural radioactivity concentrations due to Ra-226, Ra-228, Th-232 and K-40 radionuclides. Twenty nine fodder samples were analyzed by using low-level gamma-spectrometric. Based on radionuclides concentrations in animal fodder and annual consumption rate, the human health risk from irradiation due to indirect ingestion can be assessed. The annual effective dose from these radionuclides, which may reach the local consumer through beef, milk, poultry and eggs consumption have been estimated as 2.7 E +00, 1.4 E +01, 1.0 E -01 and 1.4 E -01 μSv/y, respectively

  19. Radiobiological aspects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation

    International Nuclear Information System (INIS)

    Turesson, I.

    1990-01-01

    The biological effects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation in interstitial and intracavitary radiotherapy and total body irradiation are discussed in terms of dose-rate fractionation sensitivity for various tissues. A scaling between dose-rate and fraction size was established for acute and late normal-tissue effects which can serve as a guideline for local treatment in the range of dose rates between 0.02 and 0.005 Gy/min and fraction sizes between 8.5 and 2.5 Gy. This is valid provided cell-cycle progression and proliferation can be ignored. Assuming that the acute and late tissue responses are characterized by α/β values of about 10 and 3 Gy and a mono-exponential repair half-time of about 3 h, the same total doses given with either of the two methods are approximately equivalent. The equivalence for acute and late non-hemopoietic normal tissue damage is 0.02 Gy/min and 8.5 Gy per fraction; 0.01 Gy/min and 5.5 Gy per fraction; and 0.005 Gy/min and 2.5Gy per fraction. A very low dose rate, below 0.005 Gy/min, is thus necessary to simulate high dose-rate radiotherapy with fraction sizes of about 2Gy. The scaling factor is, however, dependent on the repair half-time of the tissue. A review of published data on dose-rate effects for normal tissue response showed a significantly stronger dose-rate dependence for late than for acute effects below 0.02 Gy/min. There was no significant difference in dose-rate dependence between various acute non-hemopoietic effects or between various late effects. The consistent dose-rate dependence, which justifies the use of a general scaling factor between fraction size and dose rate, contrasts with the wide range of values for repair half-time calculated for various normal-tissue effects. This indicates that the model currently used for repair kinetics is not satisfactory. There are also few experimental data in the clinical dose-rate range, below 0.02 Gy/min. It is therefore

  20. Neuroprotection and mechanisms of atractylenolide III in preventing learning and memory impairment induced by chronic high-dose homocysteine administration in rats.

    Science.gov (United States)

    Zhao, H; Ji, Z-H; Liu, C; Yu, X-Y

    2015-04-02

    Studies demonstrated that chronic high-dose homocysteine administration induced learning and memory impairment in animals. Atractylenolide III (Aen-III), a neuroprotective constituent of Atractylodis macrocephalae Koidz, was isolated in our previous study. In this study, we investigated potential benefits of Aen-III in preventing learning and memory impairment following chronic high-dose homocysteine administration in rats. Results showed that administration of Aen-III significantly ameliorated learning and memory impairment induced by chronic high-dose homocysteine administration in rats, decreased homocysteine-induced reactive oxygen species (ROS) formation and restored homocysteine-induced decrease of phosphorylated protein kinase C expression level. Moreover, Aen-III protected primary cultured neurons from apoptotic death induced by homocysteine treatment. This study provides the first evidence for the neuroprotective effect of Aen-III in preventing learning and impairment induced by chronic administration of homocysteine. Aen-III may have therapeutic potential in treating homocysteine-mediated cognitive impairment and neuronal injury. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  1. Oral dosing by voluntary  administration of jellybeans. Refinement and reduction of variability

    DEFF Research Database (Denmark)

    Pakula, Malgorzata Maria; Dagnæs-Hansen, Frederik

    2016-01-01

    Administration of substances by oral gavage is a common procedure in biomedical research involving laboratory animals, however although highly efficient, the procedure includes fixation of the animals and is technically challenging. Oral gavage is a precise way to dose animals, however it may ind...

  2. Statistical behavior of high doses in medical radiodiagnosis; Comportamento estatistico das altas doses em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana Elisa, E-mail: adrianaebarboza@gmail.com, E-mail: elisa@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  3. The histomorphological findings of kidneys after application of high dose and high-energy shock wave lithotripsy.

    Science.gov (United States)

    Demir, Aslan; Türker, Polat; Bozkurt, Suheyla Uyar; İlker, Yalcin Nazmi

    2015-01-01

    In this animal study, we reviewed the histomorphological findings in rabbit kidneys after a high number of high-energy shock wave applications and observed if there were any cumulative effects after repeated sessions. We formed 2 groups, each consisting of 8 rabbits. Group 1 received 1 session and group 2 received 3 sessions of ESWL with a 7 day interval between sessions, consisting of 3500 beats to the left kidney and 5500 beats to the right kidney per session. The specimens of kidneys were examined histomorphologically after bilateral nephrectomy was performed. For statistical analysis, 4 groups of specimens were formed. The first and second groups received 1 session, 3500 and 5500 beats, respectively. The third and fourth groups received 3 sessions, at 3500 and 5500 beats per each session, respectively. The sections were evaluated under a light microscope to determine subcapsular thickening; subcapsular, intratubular and parenchymal hemorrhage; subcapsular, intersitital, perivascular and proximal ureteral fibrosis; paranchymal necrosis; tubular epithelial vacuolization; tubular atrophy; glomerular destruction and calcification. In histopathological examinations capsular thickening, subcapsular hematoma, tubuloepithelial vacuolisation, glomerular destruction, parenchymal hemorrhage, interstitial fibrosis, and perivascular fibrosis were observed in all groups. In statistical analysis, on the basis of perivascular fibrosis and tubular atrophy, there was a beats per session dependent increase of both. The detrimental effects from ESWL are dose dependent but not cumulative for up to 3 sessions. Histopathological experimental animal studies will aid in understanding local and maybe, by means of these local effects, systemic effects.

  4. Effects of low priming dose irradiation on cell cycle arrest of HepG2 cells caused by high dose irradiation

    International Nuclear Information System (INIS)

    Xia Jingguang; Jin Xiaodong; Chinese Academy of Sciences, Beijing; Li Wenjian; Wang Jufang; Guo Chuanling; Gao Qingxiang

    2005-01-01

    Human hepatoma cells hepG2 were irradiated twice by 60 Co γ-rays with a priming dose of 5 cGy and a higher dose of 3 Gy performed 4h or 8h after the low dose irradiation. Effects of the priming dose irradiation on cell cycle arrest caused by high dose were examined with flow cytometry. Cells in G 2 /M phase accumulated temporarily after the 5 cGy irradiation, and proliferation of tumor cells was promoted significantly by the low dose irradiation. After the 3 Gy irradiation, G 2 phase arrest occurred, and S phase delayed temporally. In comparison with 3 kGy irradiation only, the priming dose delivered 4h prior to the high dose irradiation facilitated accumulation of hepG2 cells in G 2 /M phase, whereas the priming dose delivered 8h prior to the high dose irradiation helped the cells to overcome G 2 arrest. It was concluded that effects of the priming dose treatment on cell cycle arrest caused by high dose irradiation were dependent on time interval between the two irradiations. (authors)

  5. A clinical comparison of high dose and low dose of Suxamethonium

    Directory of Open Access Journals (Sweden)

    RK Yadav

    2014-01-01

    Full Text Available Background: Suxamethonium having its rapid onset and short duration of action makes this drug unique amongst the neuromuscular blocking drugs described so far. However, use of suxamethonium is associated with a large number of undesirable side effects. Objective: To evaluate clinical effects of high and low dose of suxamethonium and to determine whether lower dose of suxamethonium can be used for any beneficial effects in terms of its various adverse effects e.g. cardiovascular responses, post-operative muscle pains and intraocular pressure. Methods: A total of 100 patients were included in this prospective study. All these patients on preoperative clinical evaluation were assessed to have adequate airway. All the patients were divided in two groups, low dose group (group I and High dose group (group II with 50 patients in each at random. A standard anesthetic technique was adhered to all the patients and following parameters were observed on comparative basis: a. Fasciculation and post operative myalgia. b. Cardiovascular effects, c. Intraocular pressure. Observation: The incidence of post Suxamethonium pain was significantly greater in group II. Increase in heart rate from baseline was significant in both groups. There was no significant difference between the two groups in the diastolic pressure but rise in systolic blood pressure was significant at all assessment times in both groups. This rise from control was statistically significant. Conclusion: Suxamethonium can be used in lower doses (0.5 mg/kg in elective cases without airway compromise. It gives benefits of reduced muscle pains, cardiovascular responses and intraocular hypertension. Journal of College of Medical Sciences-Nepal, 2013, Vol-9, No-2, 1-8 DOI: http://dx.doi.org/10.3126/jcmsn.v9i2.9677

  6. Probability distribution of dose rates in the body tissue as a function of the rhytm of Sr90 administration and the age of animals

    International Nuclear Information System (INIS)

    Rasin, I.M.; Sarapul'tsev, I.A.

    1975-01-01

    The probability distribution of tissue radiation doses in the skeleton were studied in experiments on swines and dogs. When introducing Sr-90 into the organism from the day of birth till 90 days dose rate probability distribution is characterized by one, or, for adult animals, by two independent aggregates. Each of these aggregates correspond to the normal distribution law

  7. Beneficial effects of low dose Musa paradisiaca on the semen quality of male Wistar rats.

    Science.gov (United States)

    Alabi, A S; Omotoso, Gabriel O; Enaibe, B U; Akinola, O B; Tagoe, C N B

    2013-03-01

    This study aimed at determining the effects of administration of mature green fruits of Musa paradisiaca on the semen quality of adult male Wistar rats. THE ANIMALS USED FOR THE STUDY WERE GROUPED INTO THREE: the control group, given 2 ml of double distilled water, a low dose group given 500 mg/kg/day and a high dose group given 1000 mg/kg/day of the plantain fruits, which was made into flour, and dissolved in 2 ml of double distilled water for easy oral administration. Significant increment in the semen parameters was noticed in animals that received a lower dose of the plantain flour, but those animals who received the high dose had marked and very significant reduction in sperm cell concentration and percentage of morphologically normal spermatozoa. Musa paradisiaca should be consumed in moderate quantities in order to derive its beneficial effects of enhancing male reproductive functions.

  8. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxi...

  9. Methotrexate osteopathy in long-term, low-dose methotrexate treatment for psoriasis and rheumatoid arthritis

    NARCIS (Netherlands)

    Zonneveld, I. M.; Bakker, W. K.; Dijkstra, P. F.; Bos, J. D.; van Soesbergen, R. M.; Dinant, H. J.

    1996-01-01

    In dermatology and rheumatology, methotrexate is frequently prescribed in low dosages per week; in oncology, high dosages per week are prescribed. Methotrexate osteopathy was first reported in children with leukemia treated with high doses of methotrexate. In animal studies, low doses of

  10. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  11. Consequences of low dose ionizing radiation exposure on the hippocampal microenvironment.

    Directory of Open Access Journals (Sweden)

    Munjal M Acharya

    Full Text Available The response of the brain to irradiation is complex, involving a multitude of stress inducible pathways that regulate neurotransmission within a dynamic microenvironment. While significant past work has detailed the consequences of CNS radiotherapy following relatively high doses (≥ 45 Gy, few studies have been conducted at much lower doses (≤ 2 Gy, where the response of the CNS (like many other tissues may differ substantially from that expected from linear extrapolations of high dose data. Low dose exposure could elicit radioadaptive modulation of critical CNS processes such as neurogenesis, that provide cellular input into hippocampal circuits known to impact learning and memory. Here we show that mice deficient for chemokine signaling through genetic disruption of the CCR2 receptor exhibit a neuroprotective phenotype. Compared to wild type (WT animals, CCR2 deficiency spared reductions in hippocampal neural progenitor cell survival and stabilized neurogenesis following exposure to low dose irradiation. While radiation-induced changes in microglia levels were not found in WT or CCR2 deficient animals, the number of Iba1+ cells did differ between each genotype at the higher dosing paradigms, suggesting that blockade of this signaling axis could moderate the neuroinflammatory response. Interestingly, changes in proinflammatory gene expression were limited in WT animals, while irradiation caused significant elevations in these markers that were attenuated significantly after radioadaptive dosing paradigms in CCR2 deficient mice. These data point to the importance of chemokine signaling under low dose paradigms, findings of potential significance to those exposed to ionizing radiation under a variety of occupational and/or medical scenarios.

  12. Accelerated Irradiations for High Dose Microstructures in Fast Reactor Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhijie [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-31

    The objective of this project is to determine the extent to which high dose rate, self-ion irradiation can be used as an accelerated irradiation tool to understand microstructure evolution at high doses and temperatures relevant to advanced fast reactors. We will accomplish the goal by evaluating phase stability and swelling of F-M alloys relevant to SFR systems at very high dose by combining experiment and modeling in an effort to obtain a quantitative description of the processes at high and low damage rates.

  13. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  14. Collimator optimization for small animal radiation therapy at a micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Felix, Manuela C. [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Glatting, Gerhard [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Giordano, Frank A.; Wenz, Frederik; Fleckenstein, Jens [Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Brockmann, Marc A. [Heidelberg Univ., Mannheim (Germany). Dept. of Neuroradiology; University Medical Center Mainz (Germany). Dept. of Neuroradiology

    2017-05-01

    In radiation therapy of small animals treatment depths range from a few millimetres to several centimetres. In order to spare surrounding organs at risk steep dose gradients are necessary. To minimize the treatment time, and therefore the strain to the animals, a high dose rate is required. A description how these parameters can be optimized through an appropriate choice of collimators with different source surface distances (SSD) as well as different materials and geometries is presented. An industrial micro-CT unit (Y.Fox, YXLON GmbH, Hamburg, Germany) was converted into a precision irradiator for small animals. Different collimators of either stainless steel (Fe) with cylindrical bores (SSD = 42 mm) or tungsten (W) with conical bores (SSD = 14 mm) were evaluated. The dosimetry of very small radiation fields presents a challenge and was performed with GafChromic EBT3 films (Ashland, Vayne, KY, USA) in a water phantom. The films were calibrated with an ionization chamber in the uncollimated field. Treatments were performed via a rotation of the objects with a fixed radiation source. As expected, the shorter SSD of the W-collimators resulted in a (4.5 ± 1.6)-fold increase of the dose rates compared to the corresponding Fe-collimators. The ratios of the dose rates at 1 mm and 10 mm depth in the water phantom was (2.6 ± 0.2) for the Fe- and (4.5 ± 0.1) for the W-collimators. For rotational treatments in a cylindrical plastic phantom maximum dose rates of up to 1.2 Gy/min for Fe- and 5.1 Gy/min for W-collimators were measured. Choosing the smallest possible SSD leads to a high dose rate and a high surface dose, which is of advantage for the treatment of superficial target volumes. For larger SSD the dose rate is lower and the depth dose curve is shallower. This leads to a reduction of the surface dose and is best suited for treatments of deeper seated target volumes. Divergent collimator bores have, due to the reduced scatter within the collimators, a steeper

  15. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  16. Neuroprotective potential of high-dose biotin.

    Science.gov (United States)

    McCarty, Mark F; DiNicolantonio, James J

    2017-11-01

    A recent controlled trial has established that high-dose biotin supplementation - 100 mg, three times daily - has a stabilizing effect on progression of multiple sclerosis (MS). Although this effect has been attributed to an optimization of biotin's essential cofactor role in the brain, a case can be made that direct stimulation of soluble guanylate cyclase (sGC) by pharmacological concentrations of biotin plays a key role in this regard. The utility of high-dose biotin in MS might reflect an anti-inflammatory effect of cGMP on the cerebral microvasculature, as well on oligodendrocyte differentiation and on Schwann cell production of neurotrophic factors thought to have potential for managing MS. But biotin's ability to boost cGMP synthesis in the brain may have broader neuroprotective potential. In many types of neurons and neural cells, cGMP exerts neurotrophic-mimetic effects - entailing activation of the PI3K-Akt and Ras-ERK pathways - that promote neuron survival and plasticity. Hippocampal long term potentiation requires nitric oxide synthesis, which in turn promotes an activating phosphorylation of CREB via a pathway involving cGMP and protein kinase G (PKG). In Alzheimer's disease (AD), amyloid beta suppresses this mechanism by inhibiting sGC activity; agents which exert a countervailing effect by boosting cGMP levels tend to restore effective long-term potentiation in rodent models of AD. Moreover, NO/cGMP suppresses amyloid beta production within the brain by inhibiting expression of amyloid precursor protein and BACE1. In conjunction with cGMP's ability to oppose neuron apoptosis, these effects suggest that high-dose biotin might have potential for the prevention and management of AD. cGMP also promotes neurogenesis, and may lessen stroke risk by impeding atherogenesis and hypertrophic remodeling in the cerebral vasculature. The neuroprotective potential of high-dose biotin likely could be boosted by concurrent administration of brain

  17. Polybutadiene and Styrene-Butadiene rubbers for high-dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Lucas N. [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Goiania, Goiania -GO (Brazil); Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil); Vieira, Silvio L. [Instituto de Fisica, Universidade Federal de Goias-UFG, Campus Samambaia, Goiania-GO (Brazil); Schimidt, Fernando [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Inhumas, Inhumas-GO (Brazil); Antonio, Patricia L.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil)

    2015-07-01

    Polybutadiene and Styrene-Butadiene are synthetical rubbers used widely for pneumatic tires manufacturing. In this research, the dosimeter characteristics of those rubbers were studied for application in high-dose dosimetry. The rubber samples were irradiated with doses of 10 Gy up to 10 kGy, using a {sup 60}Co Gamma Cell-220 system (dose rate of 1.089 kGy/h) and their readings were taken on a Fourier Transform Infrared Spectroscopy-FTIR system (model Frontier/Perkin Elmer). The ratios of two absorbance peaks were taken for each kind of rubber spectrum, Polybutadiene (1306/1130 cm{sup -1}) and Styrene-Butadiene (1449/1306 cm{sup -1}). The ratio calculated was used as the response to the irradiation, and is not uniform across the sample. From the results, it can be concluded for both rubbers: a) the dose-response curves may be useful for high-dose dosimetry (greater than 250 Gy); b) their response for reproducibility presented standard deviations lower than 2.5%; c) the relative sensitivity was higher for Styrene-Butadiene (1.86 kGy{sup -1}) than for Polybutadiene (1.81 kGy{sup -1}), d) for doses of 10 kGy to 200 kGy, there was no variation in the dosimetric response. Both types of rubber samples showed usefulness as high-dose dosimeters. (authors)

  18. Opposite effects of low and high doses of Abeta42 on electrical network and neuronal excitability in the rat prefrontal cortex.

    Science.gov (United States)

    Wang, Yun; Zhang, Guangping; Zhou, Hongwei; Barakat, Amey; Querfurth, Henry

    2009-12-21

    Changes in neuronal synchronization have been found in patients and animal models of Alzheimer's disease (AD). Synchronized behaviors within neuronal networks are important to such complex cognitive processes as working memory. The mechanisms behind these changes are not understood but may involve the action of soluble beta-amyloid (Abeta) on electrical networks. In order to determine if Abeta can induce changes in neuronal synchronization, the activities of pyramidal neurons were recorded in rat prefrontal cortical (PFC) slices under calcium-free conditions using multi-neuron patch clamp technique. Electrical network activities and synchronization among neurons were significantly inhibited by low dose Abeta42 (1 nM) and initially by high dose Abeta42 (500 nM). However, prolonged application of high dose Abeta42 resulted in network activation and tonic firing. Underlying these observations, we discovered that prolonged application of low and high doses of Abeta42 induced opposite changes in action potential (AP)-threshold and after-hyperpolarization (AHP) of neurons. Accordingly, low dose Abeta42 significantly increased the AP-threshold and deepened the AHP, making neurons less excitable. In contrast, high dose Abeta42 significantly reduced the AP-threshold and shallowed the AHP, making neurons more excitable. These results support a model that low dose Abeta42 released into the interstitium has a physiologic feedback role to dampen electrical network activity by reducing neuronal excitability. Higher concentrations of Abeta42 over time promote supra-synchronization between individual neurons by increasing their excitability. The latter may disrupt frontal-based cognitive processing and in some cases lead to epileptiform discharges.

  19. Opposite effects of low and high doses of Abeta42 on electrical network and neuronal excitability in the rat prefrontal cortex.

    Directory of Open Access Journals (Sweden)

    Yun Wang

    Full Text Available Changes in neuronal synchronization have been found in patients and animal models of Alzheimer's disease (AD. Synchronized behaviors within neuronal networks are important to such complex cognitive processes as working memory. The mechanisms behind these changes are not understood but may involve the action of soluble beta-amyloid (Abeta on electrical networks. In order to determine if Abeta can induce changes in neuronal synchronization, the activities of pyramidal neurons were recorded in rat prefrontal cortical (PFC slices under calcium-free conditions using multi-neuron patch clamp technique. Electrical network activities and synchronization among neurons were significantly inhibited by low dose Abeta42 (1 nM and initially by high dose Abeta42 (500 nM. However, prolonged application of high dose Abeta42 resulted in network activation and tonic firing. Underlying these observations, we discovered that prolonged application of low and high doses of Abeta42 induced opposite changes in action potential (AP-threshold and after-hyperpolarization (AHP of neurons. Accordingly, low dose Abeta42 significantly increased the AP-threshold and deepened the AHP, making neurons less excitable. In contrast, high dose Abeta42 significantly reduced the AP-threshold and shallowed the AHP, making neurons more excitable. These results support a model that low dose Abeta42 released into the interstitium has a physiologic feedback role to dampen electrical network activity by reducing neuronal excitability. Higher concentrations of Abeta42 over time promote supra-synchronization between individual neurons by increasing their excitability. The latter may disrupt frontal-based cognitive processing and in some cases lead to epileptiform discharges.

  20. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  1. Mouse spermatogonia exposed to a high, multiply fractionated dose of a cancer chemotherapeutic drug: mutation analysis by electrophoresis.

    Science.gov (United States)

    Johnson, F M; Lewis, S E

    1981-04-01

    Male mice of the DBA/2J strain were injected with procarbazine at a dose of 200 mg/kg body weight twice weekly until an accumulated dose of 2400 mg/kg was reached. A concurrent control group, injected only with the vehicle (saline) was also established. Most of the treated animals died as a result of exposure and all survivors became temporarily sterile. After regaining fertility the few survivors were repeatedly mated with C57BL/6J females over several weeks time to generate a population of F1 animals. The parental animals and the F1 were subsequently analyzed by electrophoresis for the occurrence of newly arisen mutations of spermatogonial origin. A mutation in the gene Pep-3 was found.

  2. Safety and tolerability of high doses of glucocorticoides

    Directory of Open Access Journals (Sweden)

    Rakić Branislava D.

    2016-01-01

    Full Text Available Introduction: Treatment of acute lymphoblastic leukemia includes the use of high doses of glucocorticoides (prednisone and dexamethasone, which significantly increase the success of therapy due to lymphocytolitic effect. The aim: The aim of the study was to determine tolerability of high doses of prednisone and dexamethasone in children with acute lymphoblastic leukemia and the structure and the intensity of adverse effects, occurred after application of these medicines. Subjects and methods: In a prospective study, we analyzed adverse effects of high doses of glucocorticoides in children suffering acute lymphoblastic leukemia treated in the Institute for Child and Youth Health Care of Vojvodina, since December 2010. until October 2014, were analyzed. This study included 18 patients, aged from 2 to 15 years. Results: Hyperglycemia appeared in 89% of patients treated with prednisone and in 61% of patients treated with dexamethasone. In order to control the high blood glucose level (above 10 mmol /L, in 11% of patients insulin was used. Hypertension appeared in 28% patients treated with prednisone and dexamethasone. Antihypertensives were needed for regulation in 17% patients. Hypopotassemia and hypocalcaemia were significantly more expressed after the use of prednisone in comparison to dexamethasone. In 11% of patients, the treatment with dexamethasone caused depressive behavior, followed by agitation. Conclusion: Adverse effects of dexamethasone and prednisone, administered in high doses in children with ALL were known, expected and reversible. Adverse reactions usually disappeared spontaneously or after short-term symptomatic therapy.

  3. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  4. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  5. High-dose secondary calibration laboratory accreditation program

    International Nuclear Information System (INIS)

    Humphreys, J.C.

    1993-01-01

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program

  6. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with

  7. High-dose erythropoietin for tissue protection

    DEFF Research Database (Denmark)

    Lund, Anton; Lundby, Carsten; Olsen, Niels Vidiendal

    2014-01-01

    BACKGROUND: The discovery of potential anti-apoptotic and cytoprotective effects of recombinant human erythropoietin (rHuEPO) has led to clinical trials investigating the use of high-dose, short-term rHuEPO therapy for tissue protection in conditions such as stroke and myocardial infarction....... Experimental studies have been favourable, but the clinical efficacy has yet to be validated. MATERIALS AND METHODS: We have reviewed clinical studies regarding the use of high-dose, short-term rHuEPO therapy for tissue protection in humans with the purpose to detail the safety and efficacy of r...... no effect of rHuEPO therapy on measures of tissue protection. Five trials including 1025 patients reported safety concerns in the form of increased mortality or adverse event rates. No studies reported reduced mortality. CONCLUSIONS: Evidence is sparse to support a tissue-protective benefit of r...

  8. The histomorphological findings of kidneys after application of high dose and high-energy shock wave lithotripsy

    Science.gov (United States)

    Türker, Polat; Bozkurt, Suheyla Uyar; İlker, Yalcin Nazmi

    2015-01-01

    Introduction In this animal study, we reviewed the histomorphological findings in rabbit kidneys after a high number of high-energy shock wave applications and observed if there were any cumulative effects after repeated sessions. Material and methods We formed 2 groups, each consisting of 8 rabbits. Group 1 received 1 session and group 2 received 3 sessions of ESWL with a 7 day interval between sessions, consisting of 3500 beats to the left kidney and 5500 beats to the right kidney per session. The specimens of kidneys were examined histomorphologically after bilateral nephrectomy was performed. For statistical analysis, 4 groups of specimens were formed. The first and second groups received 1 session, 3500 and 5500 beats, respectively. The third and fourth groups received 3 sessions, at 3500 and 5500 beats per each session, respectively. The sections were evaluated under a light microscope to determine subcapsular thickening; subcapsular, intratubular and parenchymal hemorrhage; subcapsular, intersitital, perivascular and proximal ureteral fibrosis; paranchymal necrosis; tubular epithelial vacuolization; tubular atrophy; glomerular destruction and calcification. Results In histopathological examinations capsular thickening, subcapsular hematoma, tubuloepithelial vacuolisation, glomerular destruction, parenchymal hemorrhage, interstitial fibrosis, and perivascular fibrosis were observed in all groups. In statistical analysis, on the basis of perivascular fibrosis and tubular atrophy, there was a beats per session dependent increase of both. Conclusions The detrimental effects from ESWL are dose dependent but not cumulative for up to 3 sessions. Histopathological experimental animal studies will aid in understanding local and maybe, by means of these local effects, systemic effects. PMID:25914842

  9. High-dose external beam irradiation inhibits neointima formation in stented pig coronary arteries

    International Nuclear Information System (INIS)

    Verheye, Stefan; Coussement, Patrick K.; Salame, Mahomed Y.; Fallahi, Payam; Cui Jianhua; Chronos, Nicolas A.F.; King, Spencer B.; Crocker, Ian R.; Robinson, Keith A.

    2001-01-01

    Purpose: To evaluate high-dose external beam irradiation (EBRT) in a pig coronary stent preparation because low and intermediate-dose EBRT failed to show inhibition of neointima formation in stented animal models. Methods and Materials: Thirty-five stents were implanted in the coronary arteries of 17 pigs. Seven pigs were exposed to a single dose of 21 Gy EBRT immediately after stenting. Ten stented, nonirradiated pigs served as controls. After 4 weeks, the study arteries and myocardium were examined by light and scanning electron microscopy. Results: Compared with controls, 21 Gy EBRT resulted in a larger lumen area (7.57±1.67 mm 2 vs. 4.00±1.63 mm 2 , p 2 vs. 3.36±2.26 mm 2 , p<0.001) and a smaller maximal intimal thickness (0.16±0.09 mm vs. 0.68±0.31 mm, p<0.001). Unresorbed intramural hemorrhages and adherent mural thrombi were present in the irradiated vessels, which also showed incomplete re-endothelialization. The irradiated hearts demonstrated diffuse interstitial and perivascular inflammation and fibrosis. Conclusions: EBRT at 21 Gy to the entire heart significantly inhibited neointima formation in stented pig coronary arteries but also resulted in incomplete re-endothelialization, myocardial inflammation, and fibrosis. Improvements in localization and delivery techniques are required to allow clinical implementation of this technique

  10. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    International Nuclear Information System (INIS)

    Cunha, Elisete L.; Schimitberger, Thiago

    2017-01-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm -1 and 3271 cm -1 , with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  11. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Elisete L.; Schimitberger, Thiago, E-mail: elisete.cunha@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Oliveira, Cristiana M.; Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm{sup -1} and 3271 cm{sup -1}, with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  12. Low-dose effects of hormones and endocrine disruptors.

    Science.gov (United States)

    Vandenberg, Laura N

    2014-01-01

    Endogenous hormones have effects on tissue morphology, cell physiology, and behaviors at low doses. In fact, hormones are known to circulate in the part-per-trillion and part-per-billion concentrations, making them highly effective and potent signaling molecules. Many endocrine-disrupting chemicals (EDCs) mimic hormones, yet there is strong debate over whether these chemicals can also have effects at low doses. In the 1990s, scientists proposed the "low-dose hypothesis," which postulated that EDCs affect humans and animals at environmentally relevant doses. This chapter focuses on data that support and refute the low-dose hypothesis. A case study examining the highly controversial example of bisphenol A and its low-dose effects on the prostate is examined through the lens of endocrinology. Finally, the chapter concludes with a discussion of factors that can influence the ability of a study to detect and interpret low-dose effects appropriately. © 2014 Elsevier Inc. All rights reserved.

  13. Histopathological changes in the kidney of experimental animals caused by lethal doses of thallium

    Energy Technology Data Exchange (ETDEWEB)

    Danilewicz, M; Danilewicz, M; Kurnatowski, A

    1979-01-01

    The experiment was carried out on 65 white male Wistar rats and 65 white male Swiss mice poisoned with thallium sulfate in doses 30 to 40 mg/kg body weight. The animals were sacrificed in the 4, 8, 24, 48th hours of experiment and their kidneys were submitted to light and an electron microscopic examination. With the light microscope necrosis of epithelium of Henle loops, hydropic degeneration, swelling and focal necrosis of epithelium of proximal convoluted tubules, and stromal oedema were seen. An electron microscopic study pointed out swelling and degenerative changes in the mitochondria, loss of microvilli in many cells, dilatation of endoplasmic reticulum and decrease of electron density of basement membranes. Urea level in blood serum and protein level in urine increased.

  14. Methodology of high dose research in medical radiodiagnostic; Metodologia de investigacao de doses elevadas em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana E.; Martins, Cintia P. de S., E-mail: ird@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations.

  15. Life shortening, tumor induction, and tissue dose for fission-neutron and gamma-ray irradiations

    International Nuclear Information System (INIS)

    Grahn, D.; Duggal, K.; Lombard, L.S.

    1985-01-01

    The primary focus of this program is to obtain information on the late effects of whole body exposure to low doses of a high linear-energy-transfer (LET) and a low-LET ionizing radiation in experimental animals to provide guidance for the prediction of radiation hazards to man. The information obtained takes the form of dose-response curves for life shortening and for the induction of numerous specific types of tumors. The animals are irradiated with fission neutrons from the Janus reactor and with 60 Co gamma rays, delivered as single, weekly, or duration-of-life exposures covering the range of doses and dose rates. 6 refs

  16. An evaluation of high-dose jobs for ALARA improvement

    International Nuclear Information System (INIS)

    Mun, J. H.; Kim, H. S.

    1997-01-01

    It is well known that about 70 percent of occupational dose have incurred from maintenance jobs at outage period. To reduce occupational dose, first, the high-dose jobs at the outage period should be identified and evaluated. For this, the database program is used, which contains the ORE data of reference plants, Kori Units 3 and 4. As a result, it is found that the jobs related to steam generator are the highest dose jobs in terms of collective ORE dose. From the analysis of the job procedures of those jobs, the ALARA improvements are also derived

  17. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  18. measurement of high dose radiation using yellow perspex dosimeter

    International Nuclear Information System (INIS)

    Thamrin, M Thoyib; Sofyan, Hasnel

    1996-01-01

    Measurement of high dose radiation using yellow perspex dosemeter has been carried out. Dose range used was between 0.1 to 3.0 kGy. Measurement of dose rate against Fricke dosemeter as a standard dose meter From the irradiation of Fricke dosemeter with time variation of 3,6,9,12,15 and 18 minute, it was obtained average dose rate of 955.57 Gy/hour, linear equation of dose was Y= 2.333+15.776 X with its correlation factor r = 0.9999. Measurement result using yellow perspex show that correlation between net optical density and radiation dose was not linear with its equation was ODc exp. [Bo + In(dose).Bi] Value of Bo = -0.215 and Bi=0.5020. From the experiment it was suggested that routine dosimeter (yellow perspex) should be calibrated formerly against standard dosemeters

  19. Striking regression of subcutaneous fibrosis induced by high doses of gamma rays using a combination of pentoxifylline and α-tocopherol: an experimental study

    International Nuclear Information System (INIS)

    Lefaix, Jean-Louis; Delanian, Sylvie; Vozenin, Marie-Catherine; Leplat, Jean-Jacques; Tricaud, Yves; Martin, Michele

    1999-01-01

    Purpose: To establish a successful treatment of subcutaneous fibrosis developing after high doses of gamma rays, suitable for use in clinical practice. Methods and Materials: We used an animal model of acute localized gamma irradiation simulating accidental overexposure in humans. Three groups of 5 Large White pigs were irradiated using a collimated 192 Ir source to deliver a single dose of 160 Gy onto the skin surface (100%) of the outer side of the thigh. A well-defined block of necrosis developed within a few weeks which had healed after 26 weeks to leave a block of subcutaneous fibrosis involving skin and skeletal muscle. One experimental group of 5 pigs was dosed orally for 26 weeks starting 26 weeks after irradiation with 1600 mg/120 kg body weight of pentoxifylline (PTX) included in the reconstituted food during its fabrication, and another group of 5 was dosed orally for the same period with a daily dose of 1600 mg/120 kg body weight of PTX combined with 2000 IU/120 kg body weight of α-tocopherol. Five irradiated control pigs were given normal food only. Animals were assessed for changes in the density of the palpated fibrotic block and in the dimensions of the projected cutaneous surface. Depth of scar tissue was determined by ultrasound. Physical and sonographic findings were confirmed by autopsy 26 weeks after treatment started. The density, length, width, and depth of the block of fibrotic scar tissue, and the areas and volume of its projected cutaneous surface, were compared before treatment, 6 and 13 weeks thereafter, and at 26 weeks. Results: The experimental animals exhibited no change in behavior and no abnormal clinical or anatomic signs. No modifications were observed in the block of fibrotic scar tissue of pigs dosed with PTX alone. However, significant softening and shrinking of this block were noted in the pigs dosed with PTX + α-tocopherol 13 weeks after treatment started and at autopsy, when mean regression was ∼ 30% for length, ∼ 50

  20. [Effects of soybean isoflavone on born metabolism and morphology in animal model of osteoporosis rats].

    Science.gov (United States)

    Yu, Qing; Su, Yi-xiang; Wang, Wen-wei; Li, An-le; Liu, Cun-li; Wang, Yi-long; Hu, Wan-li

    2007-07-01

    To study the effects of soybean isoflavone (SI) on born metabolism and morphology in animal model of osteoporosis rats. All 70 female Sprague-Dawley (SD) rats were randomly divided into 7 groups according to the levels of total cholesterol (TC) in serum: hyper-lipoid group, estrogen group, low-dose SI group, middle-dose SI group, high-dose SI group, sham group and normal control groups. Bilateral ovaries were extirpated except sham and normal control groups. Except the rats in normal control group, the other rats were fed with high fat diet. Body weight was weighted ad unam vice per week. The estrogen, different dose of SI or deionized water were fed with intragastric administration for 12 weeks. Vena caudalis serum were collected after being ovariectomized, administered for 4 w, 8 w and killed. Serum alkaline phosphatase (AKP) activity and bone density were measured etc. To interfere of estrogen and SI might recover AKP enzyme activity after its being ovariectomized. There almost sowed no differences between high dose SI intervention and estrogen on bone density and microstructure. Bone loss due to being ovariectomized was relieved after SI intervention. SI might protect cardiocyte myofilament and mitochondrial ultramicrostructure. There was mirror image in estrogen, high dose SI group resembling the normal control group, and there was obvious damage in hyper-lipoids group. There should be effects of high dose SI on bone metabolism and morphology in animal model of osteoporosis rats. Serum AKP enzyme activity and bone density should have significantly recovered, the serum level of calcium and phosphorus were maintained after high dose intervened but no significant effects for low dose of SI.

  1. Dose and dose-rate effects of ionizing radiation: a discussion in the light of radiological protection

    Energy Technology Data Exchange (ETDEWEB)

    Ruehm, Werner [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Neuherberg (Germany); Woloschak, Gayle E. [Northwestern University, Department of Radiation Oncology, Feinberg School of Medicine, Chicago, IL (United States); Shore, Roy E. [Radiation Effects Research Foundation (RERF), Hiroshima City (Japan); Azizova, Tamara V. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Grosche, Bernd [Federal Office for Radiation Protection, Oberschleissheim (Germany); Niwa, Ohtsura [Fukushima Medical University, Fukushima (Japan); Akiba, Suminori [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Epidemiology and Preventive Medicine, Kagoshima City (Japan); Ono, Tetsuya [Institute for Environmental Sciences, Rokkasho, Aomori-ken (Japan); Suzuki, Keiji [Nagasaki University, Department of Radiation Medical Sciences, Atomic Bomb Disease Institute, Nagasaki (Japan); Iwasaki, Toshiyasu [Central Research Institute of Electric Power Industry (CRIEPI), Radiation Safety Research Center, Nuclear Technology Research Laboratory, Tokyo (Japan); Ban, Nobuhiko [Tokyo Healthcare University, Faculty of Nursing, Tokyo (Japan); Kai, Michiaki [Oita University of Nursing and Health Sciences, Department of Environmental Health Science, Oita (Japan); Clement, Christopher H.; Hamada, Nobuyuki [International Commission on Radiological Protection (ICRP), PO Box 1046, Ottawa, ON (Canada); Bouffler, Simon [Public Health England (PHE), Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot (United Kingdom); Toma, Hideki [JAPAN NUS Co., Ltd. (JANUS), Tokyo (Japan)

    2015-11-15

    The biological effects on humans of low-dose and low-dose-rate exposures to ionizing radiation have always been of major interest. The most recent concept as suggested by the International Commission on Radiological Protection (ICRP) is to extrapolate existing epidemiological data at high doses and dose rates down to low doses and low dose rates relevant to radiological protection, using the so-called dose and dose-rate effectiveness factor (DDREF). The present paper summarizes what was presented and discussed by experts from ICRP and Japan at a dedicated workshop on this topic held in May 2015 in Kyoto, Japan. This paper describes the historical development of the DDREF concept in light of emerging scientific evidence on dose and dose-rate effects, summarizes the conclusions recently drawn by a number of international organizations (e.g., BEIR VII, ICRP, SSK, UNSCEAR, and WHO), mentions current scientific efforts to obtain more data on low-dose and low-dose-rate effects at molecular, cellular, animal and human levels, and discusses future options that could be useful to improve and optimize the DDREF concept for the purpose of radiological protection. (orig.)

  2. Diagnosis of cerebral metastases by means of standard doses of Gadobutrol versus a high-dose protocol. Intraindividual evaluation of a phase-II high-dose study

    International Nuclear Information System (INIS)

    Vogl, T.J.; Friebe, C.E.; Balzer, T.; Mack, M.G.; Steiner, S.; Schedel, H.; Pegios, W.; Lanksch, W.; Banzer, D.; Felix, R.

    1995-01-01

    In a clinical phase-II study 20 patients who had been diagnosed as having brain metastases with CT or MRT were studied prospectively with Gadobutrol, a new nonionic, low osmolality contrast agent. Each patient received an initial injection of 0.1 mmol/kg body weight and an additional dose of 0.2 mmol/kg Gadobutrol 10 min later. Spinecho images were obtained before and after the two applications of Gadobutrol. Dynamic scanning (Turbo-FLASH) was performed for 3 min after each injection of the contrast agent. Both quantitative and qualitative data were intraindividually evaluated. The primary tumor was a bronchial carcinoma in 11 cases; in 9 other cases there were different primary tumors. Forty-eight hours after the use of Gadobutrol there were no adverse signs in the clinical examination, vital signs or blood and urine chemistry. Statistical analysis (Friedman test and Wilcoxon test) of the C/N ratios between tumor and white matter, percentage enhancement, and visual assessment rating revealed statistically significant superiority of high-dose Gadobutrol injection in comparison to the standard dose. The percentage enhancement increased on average from 104% after 0.1 mmol/kg to 162% after 0.3 mmol/kg Gadobutrol. Qualitative delineation and contrast of the lesions increased significantly. The use of high-dose Gadobutrol improved the detection of 36 additional lesions in 6 patients. (orig./VHE) [de

  3. High-resolution CT of the lung in asbestos-exposed subjects. Comparison of low-dose and high-dose HRCT

    International Nuclear Information System (INIS)

    Majurin, M.L.; Varpula, M.; Kurki, T.; Pakkala, L.

    1994-01-01

    The lowest possible mAs settings for high-resolution CT (HRCT) were studied on 45 individuals with suspected asbestos-related lung disease. All patients were investigated with 5 to 6 high-dose HRCT images (120 kVp/160 mA/2 s) at 3-cm intervals. At a selected level 4 additional low-dose images were obtained on each patient with lower mAs settings (100 mA/2 s, 80 mA/2 s, 60 mA/2 s, 30 mA/2 s). Thirty-seven subjects out of 45 had HRCT lesions compatible with asbestosis. HRCT images obtained with as low as 60 mA/2 s settings clearly showed pleural tractions and thickenings, parenchymal bands, honeycombing and subpleural curvilinear shadows, whereas in the evaluation of subpleural short lines and ground glass findings 80 mA/2 s were required. The lowest setting, 30 mA/2 s, was sufficient only in detecting and evaluating pleural tractions and thickenings. We conclude that 160 mAs yield good quality HRCT images, with substantial decrease of radiation dose, for the evaluation of asbestos-related lesions. (orig.)

  4. The clinical pharmacology of alkylating agents in high-dose chemotherapy

    NARCIS (Netherlands)

    Huitema, A. D.; Smits, K. D.; Mathôt, R. A.; Schellens, J. H.; Rodenhuis, S.; Beijnen, J. H.

    2000-01-01

    Alkylating agents are widely used in high-dose chemotherapy regimens in combination with hematological support. Knowledge about the pharmacokinetics and pharmacodynamics of these agents administered in high doses is critical for the safe and efficient use of these regimens. The aim of this review is

  5. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  6. Accumulation of main radionuclides that participate in exposure dose formation in liver of wild ungulate animals on the territory of the Palesse state radioecological reserve

    International Nuclear Information System (INIS)

    Korol', R.A.; Nikitin, A.N.

    2013-01-01

    The dose of internal exposure of liver of wild ungulate animals (deer, elk, boar) mainly determined by Cs 137 at present time. The dose from Cs 137 is decrease in line wild boar - deer - elk and variate from 0.3 to 104.8 mSv/y. Other 'Chernobyl' radionuclides about equally contribute in the dose. The relative role of transuranium elements are increasing and will be equal to Cs 137 after about 250 years. The role of Sr 90 will minor all time. (authors)

  7. Current modeling practice may lead to falsely high benchmark dose estimates.

    Science.gov (United States)

    Ringblom, Joakim; Johanson, Gunnar; Öberg, Mattias

    2014-07-01

    Benchmark dose (BMD) modeling is increasingly used as the preferred approach to define the point-of-departure for health risk assessment of chemicals. As data are inherently variable, there is always a risk to select a model that defines a lower confidence bound of the BMD (BMDL) that, contrary to expected, exceeds the true BMD. The aim of this study was to investigate how often and under what circumstances such anomalies occur under current modeling practice. Continuous data were generated from a realistic dose-effect curve by Monte Carlo simulations using four dose groups and a set of five different dose placement scenarios, group sizes between 5 and 50 animals and coefficients of variations of 5-15%. The BMD calculations were conducted using nested exponential models, as most BMD software use nested approaches. "Non-protective" BMDLs (higher than true BMD) were frequently observed, in some scenarios reaching 80%. The phenomenon was mainly related to the selection of the non-sigmoidal exponential model (Effect=a·e(b)(·dose)). In conclusion, non-sigmoid models should be used with caution as it may underestimate the risk, illustrating that awareness of the model selection process and sound identification of the point-of-departure is vital for health risk assessment. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Calcium carbonate as a possible dosimeter for high irradiation doses

    International Nuclear Information System (INIS)

    Negron M, A.; Ramos B, S.; Camargo R, C.; Uribe, R. M.; Gomez V, V.; Kobayashi, K.

    2014-08-01

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  9. Calcium carbonate as a possible dosimeter for high irradiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Negron M, A.; Ramos B, S.; Camargo R, C. [UNAM, Instituto de Ciencias Nucleares, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Uribe, R. M. [Kent State University, College of Technology, Kent OH (United States); Gomez V, V. [UNAM, Instituto de Quimica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Kobayashi, K., E-mail: negron@nucleares.unam.mx [Yokohama National University (Japan)

    2014-08-15

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  10. Risk of low-doses in radiodiagnosis; Risque des faibles doses en radiodiagnostic. Mythes, reglementation et rationalite

    Energy Technology Data Exchange (ETDEWEB)

    Cordoliani, Y.S.; Sarrazin, J.L.; Le Frian, G.; Soulie, D.; Leveque, C. [Hopital d`Instruction des Armees du Val-de-Grace, 75 - Paris (France)

    1997-12-31

    The effect of low doses of X-rays is inferred from the indubitable effects of high doses in human carcinogenesis, Genetic and teratogenic effects are mainly inferred from animal experimentation because clinical surveys of irradiated pregnant women have failed to demonstrate such consequences in the children, except for mental retardation after Japanese atomic bombing. Since no evidence of carcinogenic effect has been produced by epidemiological studies for doses lower than 500 mSv. the estimation of the risk due to low doses has been extrapolated from the linear relation between dose and cancers at high doses. Such an extrapolation gives a maximal risk which is falsely used as a probability of cancer. The actual risk lies between zero and this maximal number, and many epidemiologic surveys in people receiving doses much higher than the mean level of background irradiation failed to demonstrate higher rate of cancer. The explanation of this fact, which is supported by the most recent biological data, is the efficacy of the DNA repair system at low level of exposure to ionizing radiations. We expose the principles of regulation of radioprotection for workers, and give estimations of the doses delivered to the patients and the personnel by diagnostic investigations, by comparing these doses with those of natural irradiation. Practical aspect for conventional and computed radiology are exposed for patients and workers. (authors)

  11. Calibration of high-dose radiation facilities (Handbook)

    International Nuclear Information System (INIS)

    Gupta, B.L.; Bhat, R.M.

    1986-01-01

    In India at present several high intensity radiation sources are used. There are 135 teletheraphy machines and 65 high intensity cobalt-60 sources in the form of gamma chambers (2.5 Ci) and PANBIT (50 Ci). Several food irradiation facilities and a medical sterilization plant ISOMED are also in operation. The application of these high intensity sources involve a wide variation of dose from 10 Gy to 100 kGy. Accurate and reproducible radiation dosimetry is essential in the use of these sources. This handbook is especially compiled for calibration of high-dose radiation facilities. The first few chapters discuss such topics as interaction of radiation with matter, radiation chemistry, radiation processing, commonly used high intensity radiation sources and their special features, radiation units and dosimetry principles. In the chapters which follow, chemical dosimeters are discussed in detail. This discussion covers Fricke dosimeter, FBX dosimeter, ceric sulphate dosimeter, free radical dosimetry, coloured indicators for irrdiation verification. A final chapter is devoted to practical hints to be followed in calibration work. (author)

  12. Plasma Doping - Enabling Technology for High Dose Logic and Memory Applications

    International Nuclear Information System (INIS)

    Miller, T.; Godet, L.; Papasouliotis, G. D.; Singh, V.

    2008-01-01

    As logic and memory device dimensions shrink with each generation, there are more high dose implants at lower energies. Examples include dual poly gate (also referred to as counter-doped poly), elevated source drain and contact plug implants. Plasma Doping technology throughput and dopant profile benefits at these ultra high dose and lower energy conditions have been well established [1,2,3]. For the first time a production-worthy plasma doping implanter, the VIISta PLAD tool, has been developed with unique architecture suited for precise and repeatable dopant placement. Critical elements of the architecture include pulsed DC wafer bias, closed-loop dosimetry and a uniform low energy, high density plasma source. In this paper key performance metrics such as dose uniformity, dose repeatability and dopant profile control will be presented that demonstrate the production-worthiness of the VIISta PLAD tool for several high dose applications.

  13. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  14. Advances in environmental radiation protection: re-thinking animal-environment interaction modelling for wildlife dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Michael D. [School of Environment and Life Sciences, University of Salford, Manchester, M4 4WT (United Kingdom); Beresford, Nicholas A. [School of Environment and Life Sciences, University of Salford, Manchester, M4 4WT (United Kingdom); Centre for Ecology and Hydrology, Bailrigg, Lancaster, LA1 4AP (United Kingdom); Bradshaw, Clare [Department of Ecology, Environment and Plant Sciences, Stockholm University, 10691 Stockholm (Sweden); Gashchak, Sergey [Chornobyl Centre for Nuclear Safety, Radioactive Waste and Radioecology, 07100 Slavutych (Ukraine); Hinton, Thomas G. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Centre de Cadarache, 13115 Saint Paul-lez-Durance (France)

    2014-07-01

    Current wildlife dose assessment models adopt simplistic approaches to the representation of animal-environment interaction. The simplest approaches are to assume either that environmental media (e.g. soil, sediment or water) are uniformly contaminated or relating organism exposure to activity concentrations in media collected at the point of sampling of the animal. The external exposure of a reference organism is then estimated by defining the geometric relationship between the organism and the medium. For example, a reference organism within the soil would have a 4p exposure geometry and a reference organism on the soil would have a 2p exposure geometry. At best, the current modelling approaches recognise differences in media activity concentrations by calculating exposure for different areas of contamination and then estimating the fraction of time that an organism spends in each area. In other fields of pollution ecology, for example wildlife risk assessment for chemical pollution, more advanced approaches are being implemented to model animal-environment interaction and estimate exposure. These approaches include individual-based movement modelling and random walk modelling and a variety of software tools have been developed to facilitate the implementation of these models. Although there are more advanced animal-environment interaction modelling approaches that are available, it is questionable whether these should be adopted for use in environmental radiation protection. Would their adoption significantly reduce uncertainty within the assessment process and, if so, by how much? These questions are being addressed within the new TREE (TRansfer - Exposure - Effects) research programme funded by the United Kingdom Natural Environment Research Council (NERC) and within Working Group (WG) 8 of the International Atomic Energy Agency's MODARIA programme. MODARIA WG8 is reviewing some of the alternative approaches that have been developed for animal

  15. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  16. Biological dose estimation and comet analysis of the victims in a high dose 60Co radiation accident

    International Nuclear Information System (INIS)

    Chen Ying; Liu Xiulin; Luo Yisheng; Li You; Yao Bo

    2007-01-01

    Objective: To explore the methods of chromosome preparation in human peripheral blood and bone marrow after very high dose exposure and fit the dose-response curve of dicentrics and tings in the range of high doses over 6 Gy for estimating biological dose and detecting DNA damage in the victims of '10.21' accident. Methods: The samples of peripheral blood and bone marrow in 2 victims were collected to prepare chromosome mataphases and dicentrics (multicentrics) + rings were counted. The dose-response curve and equation of human blood irradiated between 6-22 Gy in vitro were established and applied to assess biological dose of 2 victims. In addition, their DNA damages were tested by alkaline single cell gel electrophoresis. Results: The dicentric + ring numbers of 4.47 per cell in victims B's peripheral blood lymphocytes and 9.15 per cell in victim A's bone marrow who had no mitosis in peripheral blood cell. The whole body average doses of victims B and A estimated by 6-22 Gy equation arrived at 9.4 Gy and 19.5 Gy, respectively. The serious DNA damages were expressed by small head and large tail comet figures. Conclusions: The biological doses of 2 victims estimated by 6-22 Gy dose-response curve have reached the levels of extreme grave bone marrow and intestinal ARS, respectively. (authors)

  17. Preservation of Minced Meats by Using Medium and High-doses Irradiation

    International Nuclear Information System (INIS)

    Hammad, A.A.I.; Swailam, H.M.H.; Taha, S.M.A.

    2003-01-01

    The effect of medium (2.5-10 kGy) dose irradiation and high(20-70 kGy) dose irradiation on the microbiological, chemical and organoleptic properties of minced meat samples was studied. It was found that irradiation dose of only 5 kGy greatly reduced all microbial counts and completely eliminated all non-spore forming pathogenic bacteria contaminated minced meat samples. Consequently this irradiation dose extended the refrigerated (3 degree ±1) storage life of these products for more than 8 weeks. This irradiation dose almost did not affect the chemical composition, particularly the main amino acids and main fatty acids of minced meat samples. Panelists could not differentiate between irradiated minced meat samples at this dose and unirradiated samples. High doses irradiation, i.e.40 and 70 kGy were sufficient and efficient in sterilization of minced meat samples and in obtaining long-stable minced meat products (Two years) at ambient temperature. These irradiation doses slightly reduced (not more than 7%) aspartic acid, glutamic acid, methionine and lysine of minced meat. It also decreased the relative percentage of total unsaturated fatty acids by not more than 17 % . These high irradiation doses caused loss of C 18:3 and C 20:1

  18. Effect of (OPC) oligomeric pronthocyanidine extracted of grape seed on chromosomal aberrations for Tc 99m sulfur colloid in laboratory animal

    International Nuclear Information System (INIS)

    Alwan, I. F.; Ahmed, A.M.; Mohamad, H. A.

    2012-12-01

    The aims study to assess the protective material (OPC) oligomeric pronthocyanidine grape seed extract, to decrease the effect of Technetium 99 m radiation used in on the (Chromosomal Aberration) in the genes for bone marrow in laboratory animals. Been diagnosed by a composite (OPC) optical spectrometer (UV.vis) to determine the wavelength of the compound, for the purpose of examination and analysis by a high-purity HPLC to determine the components of grape seed extract. Has been handing laboratory animals, grape seed extract material (OPC) at a dose (150 mg/kg) for two weeks and then were injected to the solution of sulfur colloidal label with Tc 99 m doses of radiation to the following quantity (400 u ci, 250 u ci, 150 u ci / 0.1 m1). The treated animals by extract (OPC) showed decrease in the proportion of chromosomal changes resulting from the impact of injection differences dose compared to animals injected to the same radiation dose and non treated animal with (OPC). The result indicated there are significant differences (p>0.05) at the level of changes in chromosomal in genes of animals untreated compared with the group of animals treated with (OPC) and injected with the same radiation dose compared a control animal group. (Author)

  19. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    Science.gov (United States)

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (agedphenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  20. Novel high dose rate lip brachytherapy technique to improve dose homogeneity and reduce toxicity by customized mold

    International Nuclear Information System (INIS)

    Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay

    2014-01-01

    The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a “sandwich” technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the “sandwich” technique to “classic” – interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue “hot spots” and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36–81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1–47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality

  1. Evaluation of Low- Versus High-dose Valganciclovir for Prevention of Cytomegalovirus Disease in High-risk Renal Transplant Recipients.

    Science.gov (United States)

    Gabardi, Steven; Asipenko, Natalya; Fleming, James; Lor, Kevin; McDevitt-Potter, Lisa; Mohammed, Anisa; Rogers, Christin; Tichy, Eric M; Weng, Renee; Lee, Ruth-Ann

    2015-07-01

    Despite proven efficacy of prolonged cytomegalovirus (CMV) prophylaxis using valganciclovir 900 mg/day, some centers use 450 mg/day due to reported success and cost savings. This multicenter, retrospective study compared the efficacy and safety of 6 months of low-dose versus high-dose valganciclovir prophylaxis in high-risk, donor-positive/recipient-negative, renal transplant recipients (RTR). Two hundred thirty-seven high-risk RTR (low-dose group = valganciclovir 450 mg/day [n = 130]; high-dose group = valganciclovir 900 mg/day [n = s7]) were evaluated for 1-year CMV disease prevalence. Breakthrough CMV, resistant CMV, biopsy-proven acute rejection (BPAR), graft loss, opportunistic infections (OI), new-onset diabetes after transplantation (NODAT), premature valganciclovir discontinuation, renal function and myelosuppression were also assessed. Patient demographics and transplant characteristics were comparable. Induction and maintenance immunosuppression were similar, except for more early steroid withdrawal in the high-dose group. Similar proportions of patients developed CMV disease (14.6% vs 24.3%; P = 0.068); however, controlling CMV risk factor differences through multivariate logistic regression revealed significantly lower CMV disease in the low-dose group (P = 0.02; odds ratio, 0.432, 95% confidence interval, 0.211-0.887). Breakthrough and resistant CMV occurred at similar frequencies. There was no difference in renal function or rates of biopsy-proven acute rejection, graft loss, opportunistic infections, or new-onset diabetes after transplantation. The high-dose group had significantly lower mean white blood cell counts at months 5 and 6; however, premature valganciclovir discontinuation rates were similar. Low-dose and high-dose valganciclovir regimens provide similar efficacy in preventing CMV disease in high-risk RTR, with a reduced incidence of leukopenia associated with the low-dose regimen and no difference in resistant CMV. Low-dose valganciclovir

  2. Chromosomal Aberrations in Normal and AT Cells Exposed to High Dose of Low Dose Rate Irradiation

    Science.gov (United States)

    Kawata, T.; Shigematsu, N.; Kawaguchi, O.; Liu, C.; Furusawa, Y.; Hirayama, R.; George, K.; Cucinotta, F.

    2011-01-01

    Ataxia telangiectasia (A-T) is a human autosomally recessive syndrome characterized by cerebellar ataxia, telangiectases, immune dysfunction, and genomic instability, and high rate of cancer incidence. A-T cell lines are abnormally sensitive to agents that induce DNA double strand breaks, including ionizing radiation. The diverse clinical features in individuals affected by A-T and the complex cellular phenotypes are all linked to the functional inactivation of a single gene (AT mutated). It is well known that cells deficient in ATM show increased yields of both simple and complex chromosomal aberrations after high-dose-rate irradiation, but, less is known on how cells respond to low-dose-rate irradiation. It has been shown that AT cells contain a large number of unrejoined breaks after both low-dose-rate irradiation and high-dose-rate irradiation, however sensitivity for chromosomal aberrations at low-dose-rate are less often studied. To study how AT cells respond to low-dose-rate irradiation, we exposed confluent normal and AT fibroblast cells to up to 3 Gy of gamma-irradiation at a dose rate of 0.5 Gy/day and analyzed chromosomal aberrations in G0 using fusion PCC (Premature Chromosomal Condensation) technique. Giemsa staining showed that 1 Gy induces around 0.36 unrejoined fragments per cell in normal cells and around 1.35 fragments in AT cells, whereas 3Gy induces around 0.65 fragments in normal cells and around 3.3 fragments in AT cells. This result indicates that AT cells can rejoin breaks less effectively in G0 phase of the cell cycle? compared to normal cells. We also analyzed chromosomal exchanges in normal and AT cells after exposure to 3 Gy of low-dose-rate rays using a combination of G0 PCC and FISH techniques. Misrejoining was detected in the AT cells only? When cells irradiated with 3 Gy were subcultured and G2 chromosomal aberrations were analyzed using calyculin-A induced PCC technique, the yield of unrejoined breaks decreased in both normal and AT

  3. Dose finding study of granisetron in patients receiving high-dose cisplatin chemotherapy. The Granisetron Study Group.

    Science.gov (United States)

    Riviere, A.

    1994-01-01

    The efficacy and safety of three different doses of granisetron (2 micrograms kg-1, group A; 10 micrograms kg-1, group B; 40 micrograms kg-1, group C) were compared in a randomised, double-blind study of 157 patients due to receive high-dose cisplatin therapy (mean dose > 97 mg m-2). In each group, up to two 3 mg rescue doses of granisetron were allowed if more than mild nausea or vomiting occurred. In group A 30.8%, in group B 61.5% and in group C 67.9% of patients were complete responders (i.e. no vomiting or nothing worse than mild nausea) during the first 24 h. These differences are significant between groups A and B, and A and C. There were no statistically significant differences in any efficacy variable between the 10 micrograms kg-1 and 40 micrograms kg-1 groups, although in each case the trend favoured the higher dose. Additional rescue doses resulted in resolved or improved symptoms in 95.3% for the first rescue dose and 93.3% for the second. Over the 7 days of the study, 82.7%, 82.7% and 86.8% of patients in groups A, B and C respectively were treated with granisetron alone. Headache was the most common side-effect, reported by 9.6% of patients; the majority of headaches were mild. There was no difference between the treatment groups regarding the adverse event rate. We concluded that prophylactic doses of 10 or 40 micrograms kg-1 lead to a safe and satisfactory degree of control of nausea and vomiting induced by high-dose cisplatin. PMID:8180032

  4. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F.

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients. PMID:26820986

  5. High-dose zolpidem dependence - Psychostimulant effects? A case report and literature review

    Directory of Open Access Journals (Sweden)

    Abhijna Chandan Chattopadhyay

    2016-01-01

    Full Text Available Zolpidem, an imidazoline nonbenzodiazepine sedative drug, is used widely. Initial reports showed minimal abuse potential. However, multiple reports have appeared of dose escalation and abuse. Subjective effects of high-dose zolpidem are not known. In light of accumulating evidence of abuse potential, we hereby report a case of high-dose dependence and a review of relevant literature. A 33-year-old male presented with 5 years of daily use of 600–1700 mg of zolpidem tartrate. He reported subjective effects of euphoria, intense craving, and inability to stop use. Loss of receptor specificity, pharmacokinetic factors, and different receptor distributions can explain paradoxical stimulatory effects of high-dose zolpidem. Further studies are required to characterize subjective effects of high-dose zolpidem.

  6. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  7. Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy

    International Nuclear Information System (INIS)

    Marriott, C. J.; Webber, C. E.; Gulenchyn, K. Y.

    2007-01-01

    On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of 131 I. Radiation doses for the designated caregivers were monitored on an hourly basis for 1 week using electronic personal dosemeters. The average penetrating dose was 98±64 μSv. The maximum penetrating dose was 283 μSv. Measured dose rate profiles showed that, on average, one-third of the caregiver dose was received during the journey home from hospital. The mean dose rate profile showed rapid clearance of 131 I with three distinct phases. The corresponding clearance half-times were 131 I contaminating the home. (authors)

  8. Dose response of fish oil versus safflower oil on graft arteriosclerosis in rabbit heterotopic cardiac allografts.

    Science.gov (United States)

    Yun, K L; Fann, J I; Sokoloff, M H; Fong, L G; Sarris, G E; Billingham, M E; Miller, D C

    1991-01-01

    With the advent of cyclosporin A, accelerated coronary arteriosclerosis has become the major impediment to the long-term survival of heart transplant recipients. Due to epidemiologic reports suggesting a salutary effect of fish oil, the dose response of fish oil on graft coronary arteriosclerosis in a rabbit heterotopic cardiac allograft model was assessed using safflower oil as a caloric control. Seven groups of New Zealand White rabbits (n = 10/group) received heterotropic heart transplants from Dutch-Belted donors and were immunosuppressed with low-dose cyclosporin A (7.5 mg/kg/day). Group 1 animals were fed a normal diet and served as control. Group 2, 3, and 4 animals received a daily supplement of low- (0.25 mL/kg/day), medium- (0.75 mL/kg/day), and high- (1.5 mL/kg/day) dose fish oil (116 mg n-3 polyunsaturated fatty acid/mL), respectively. Group 5, 6, and 7 animals were supplemented with equivalent dose of safflower oil (i.e., 0.25, 0.75, and 1.5 mL/kg/day). Oil-supplemented rabbits were pretreated for 3 weeks before transplantation and maintained on the same diet for 6 weeks after operation. The extent of graft coronary arteriosclerosis was quantified using computer-assisted, morphometric planimetry. When the animals were killed, cyclosporin A was associated with elevated plasma total cholesterol and triglyceride levels in the control group. While safflower oil prevented the increase in plasma lipids at all dosages, fish oil ameliorated the cyclosporin-induced increase in total cholesterol only with high doses. Compared to control animals, there was a trend for more graft vessel disease with increasing fish oil dose, as assessed by mean luminal occlusion and intimal thickness. A steeper trend was observed for increasing doses of safflower oil; compared to the high-dose safflower oil group, animals supplemented with low-dose safflower oil had less mean luminal occlusion (16.3% +/- 5.9% versus 41.4% +/- 7.6%, p less than 0.017) and intimal thickness (7

  9. High-Dose versus Low-Dose Vitamin D Supplementation and Arterial Stiffness among Individuals with Prehypertension and Vitamin D Deficiency

    Directory of Open Access Journals (Sweden)

    Amanda Zaleski

    2015-01-01

    Full Text Available Introduction. Vitamin D deficiency is associated with the onset and progression of hypertension and cardiovascular disease (CVD. However, mechanisms underlying vitamin D deficiency-mediated increased risk of CVD remain unknown. We sought to examine the differential effect of high-dose versus low-dose vitamin D supplementation on markers of arterial stiffness among ~40 vitamin D deficient adults with prehypertension. Methods. Participants were randomized to high-dose (4000 IU/d versus low-dose (400 IU/d oral vitamin D3 for 6 months. 24 hr ambulatory blood pressure (BP, carotid-femoral pulse wave velocity, and pulse wave analyses were obtained at baseline and after 6 months of vitamin D supplementation. Results. There were no changes in resting BP or pulse wave velocity over 6 mo regardless of vitamin D dose (all p>0.202. High-dose vitamin D decreased augmentation index and pressure by 12.3 ± 5.3% (p=0.047 and 4.0 ± 1.5 mmHg (p=0.02, respectively. However, these decreases in arterial stiffness were not associated with increases in serum 25-hydroxyvitamin D over 6 mo (p=0.425. Conclusion. High-dose vitamin D supplementation appears to lower surrogate measures of arterial stiffness but not indices of central pulse wave velocity. Clinical Trial Registration. This trial is registered with www.clinicaltrials.gov (Unique Identifier: NCT01240512.

  10. High dose calibrations at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    McDonald, J.C.; Fox, R.A.

    1988-10-01

    The need is increasing for both high radiation exposures and calibration measurements that provide traceability of such exposures to national standards. The applications of high exposures include: electronic component damage studies, sterilization of medical products and food irradiation. Accurate high exposure measurements are difficult to obtain and cannot, in general, be carried out with a single dose measurement system or technique because of the wide range of doses and the variety of materials involved. This paper describes the dosimetric measurement and calibration techniques used at the Pacific Northwest Laboratory (PNL) that make use of radiochromic dye films, thermoluminescent dosimeters (TLDs), ionization chambers, and calorimetric dosimeters. The methods used to demonstrate the consistency of PNL calibrations with national standards will also be discussed. 4 refs

  11. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  12. Effects of Gamma Irradiation and Pasteurization on the Nutritive Composition of Commercially Available Animal Diets

    Science.gov (United States)

    Caulfield, Catherine D; Cassidy, Joseph P; Kelly, John P

    2008-01-01

    Gamma radiation is used to sterilize diets for specific pathogen-free (SPF) animals. Because a gamma-irradiated diet was linked to leukoencephalomyelopathy in SPF cats, we investigated the effects of ‘typical’ (28.9–34.3 kGy) and ‘high-end’ (38.4–48.7 kGy) doses of gamma irradiation and of pasteurization (at 107 °C for 15 min) on the amounts of fat; protein; carbohydrate (and taurine in cat diet); vitamins A, E, B1, B2, B6, and B12; and peroxide in commercially available dry cat, dog, and rodent diets. The only treatment-related changes occurred with vitamin A and peroxide. The typical and high-end doses of gamma irradiation reduced the vitamin A level of the cat diet to 42% and 30% of the untreated value, respectively—levels below recommended allowances for growth and reproduction. Only the higher irradiation dose reduced vitamin A in the rodent diet, and neither dose altered the canine diet. Pasteurization reduced the vitamin A content of the cat diet to 50% of its original level, which was within the recommended level for this species. Irradiation increased the peroxide content of all 3 animal diets: by approximately 11-fold with the typical dose and by 14- to 25-fold with the high-end dose. Therefore gamma irradiation can have profound, selective effects on the vitamin A and peroxide contents of dry diets, and caution is advised when feeding such diets long-term and exclusively to SPF animals, particularly cats. Furthermore, pasteurization (with its fewer deleterious effects) may represent an alternative method of decontaminating diets for rodents, dogs, and cats. PMID:19049256

  13. Comparative study of SOI/Si hybrid substrates fabricated using high-dose and low-dose oxygen implantation

    International Nuclear Information System (INIS)

    Dong Yemin; Chen Meng; Chen Jing; Wang Xiang; Wang Xi

    2004-01-01

    Hybrid substrates comprising both silicon-on-insulator (SOI) and bulk Si regions have been fabricated using the technique of patterned separation by implantation of oxygen (SIMOX) with high-dose (1.5 x 10 18 cm -2 ) and low-dose ((1.5-3.5) x 10 17 cm -2 ) oxygen ions, respectively. Cross-sectional transmission electron microscopy (XTEM) was employed to examine the microstructures of the resulting materials. Experimental results indicate that the SOI/Si hybrid substrate fabricated using high-dose SIMOX is of inferior quality with very large surface height step and heavily damaged transitions between the SOI and bulk regions. However, the quality of the SOI/Si hybrid substrate is enhanced dramatically by reducing the implant dose. The defect density in transitions is reduced considerably. Moreover, the expected surface height difference does not exist and the surface is exceptionally flat. The possible mechanisms responsible for the improvements in quality are discussed

  14. Lead in teeth from lead-dosed goats: Microdistribution and relationship to the cumulative lead dose

    International Nuclear Information System (INIS)

    Bellis, David J.; Hetter, Katherine M.; Jones, Joseph; Amarasiriwardena, Dula; Parsons, Patrick J.

    2008-01-01

    Teeth are commonly used as a biomarker of long-term lead exposure. There appear to be few data, however, on the content or distribution of lead in teeth where data on specific lead intake (dose) are also available. This study describes the analysis of a convenience sample of teeth from animals that were dosed with lead for other purposes, i.e., a proficiency testing program for blood lead. Lead concentration of whole teeth obtained from 23 animals, as determined by atomic absorption spectrometry, varied from 0.6 to 80 μg g -1 . Linear regression of whole tooth lead (μg g -1 ) on the cumulative lead dose received by the animal (g) yielded a slope of 1.2, with r 2 =0.647 (p -1 , were found in circumpulpal dentine. Linear regression of circumpulpal lead (μg g -1 ) on cumulative lead dose (g) yielded a slope of 23 with r 2 =0.961 (p=0.0001). The data indicated that whole tooth lead, and especially circumpulpal lead, of dosed goats increased linearly with cumulative lead exposure. These data suggest that circumpulpal dentine is a better biomarker of cumulative lead exposure than is whole tooth lead, at least for lead-dosed goats

  15. Effects of low dose gamma radiation on the early growth of red pepper and the resistance to subsquent high dose of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Baek, M. H.; Kim, D. H.; Lee, Y. K. [KAERI, Taejon (Korea, Republic of); Lee, Y. B. [Chungnam National Univ., Taejon (Korea, Republic of)

    2001-05-01

    Red pepper (capsicum annuum L. cv. Jokwang and cv. Johong) seeds were irradiated with the dose of 0{approx}50 Gy to investigated the effect of the low dose gamma radiation on the early growth and resistance to subsequent high dose of radiation. The effect of the low dose gamma radiation on the early growth and resistance to subsequenct high dose of radiation were enhanced in Johong cultivar but not in Jokwang cultivar. Germination rate and early growth of Johong cultivar were noticeably increased at 4 Gy-, 8 Gy- and 20 Gy irradiation group. Resistance to subsequent high dose of radiation of Johong cultivar were increased at almost all of the low dose irradiation group. Especially it was highest at 4 Gy irradiation group. The carotenoid contents and enzyme activity on the resistance to subsequent high dose of radiation of Johong cultivar were increased at the 4 Gy and 8 Gy irradiation group.

  16. Radioprotection of salivary glands by S-2-(3-aminopropylamino)-ethylphosphorothioic (amifostine) obtained in a rabbit animal model

    International Nuclear Information System (INIS)

    Bohuslavizki, Karl H.; Klutmann, Susanne; Jenicke, Lars; Brenner, Winfried; Feyerabend, Bernd; Henze, Eberhard; Clausen, Malte

    1999-01-01

    Background: Impairment of salivary gland function following high-dose radioiodine treatment (HDRIT) is a well-recognized side effect of the treatment. Because differentiated thyroid cancer has an excellent prognosis, reduction of long-term side-effects is mandatory. Therefore, the aim of this study was to investigate the radioprotective effect of amifostine in a rabbit animal model. Methods: Salivary gland scintigraphy was performed in a total of 16 New Zealand White rabbits. Uptake of 99m Tc-pertechnetate was calculated in percentage of injected activity as a quantitative measure of both salivary gland and thyroid function. Reproducibility of salivary gland scintigraphy was evaluated in one rabbit without any intervention. Fifteen rabbits were studied prior to and up to 6 months after high-dose radioiodine treatment applying 2 GBq 131 I. Ten animals received 200 mg/kg amifostine prior to high-dose radioiodine therapy, and 5 served as controls. Salivary glands were examined histopathologically. Results: Variation coefficient of parenchymal function was less than 3.8% in salivary glands. Prior to HDRIT, thyroid uptake was 0.417 ± 0.373% and 0.421 ± 0.241% in control and amifostine-treated rabbits, respectively. Four weeks after HDRIT, complete ablation of the thyroid was achieved in both groups. Prior to HDRIT, uptake of 99m Tc-pertechnetate in salivary glands of five control rabbits was not significantly different from ten amifostine-treated rabbits. In control rabbits 6 months after HDRIT, parenchymal function was reduced significantly (p 0.05) in parotid and submandibular glands, respectively. Histopathologically, marked lipomatosis was observed in control animals but was negligible in amifostine-treated animals. Conclusion: Parenchymal damage in salivary glands induced by high-dose radioiodine treatment can be significantly reduced by amifostine in this rabbit animal model. This corresponds to data obtained in patients with differentiated thyroid cancer

  17. Multifocal Electroretinography after High Dose Chloroquine Therapy for Malaria

    Directory of Open Access Journals (Sweden)

    Aline Correa de Carvalho

    2013-01-01

    Full Text Available Purpose: To investigate changes in multifocal electroretinography (mfERG parameters associated with high dose chloroquine therapy for treatment of malaria in the Amazonia region of Brazil. Methods: Forty-eight subjects who had received chloroquine treatment for single or multiple malaria infections with a cumulative dose ranging from 1,050 to 27,000mg were included. The control group consisted of 37 healthy aged-matched subjects. Data was collected on amplitude and implicit time of the N1, P1 and N2 waves in the central macular hexagon (R1 and in five concentric rings at different retinal eccentricities (R2-R6. Results: No significant difference was observed in any mfERG parameter between chloroquine treated patients and control subjects. A comparison with previous data obtained from patients with rheumatologic disorders in the same region of Brazil who had received larger cumulative doses of chloroquine and had displayed mfERG changes, indicated that retinal toxicity seems to be dependent on cumulative dose. Conclusion: Lack of mfERG changes in the current study suggests that intensive high dose chloroquine therapy for treatment of malaria is not associated with retinal toxicity.

  18. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  19. Present status of radiation treatment of animal feeds in Japan

    International Nuclear Information System (INIS)

    Ito, H.; Iizuka, H.

    1979-01-01

    This paper summarizes the studies in Japan on the irradiation of laboratory animal diets and farm animal feedstuffs. From the microbiological inactivation curve of laboratory animal diets, the irradiation doses of 2.5 approximately 3.5 Mrad seem to be suitable for sterilization of animal diets. The absence of toxic effects on animals can be demonstrated by feeding studies. The elimination of salmonellae and other species of Enterobacteriaceae in feedstuffs could be achieved by irradiation with 0.5 approximately 0.6 Mrad. The growth of moulds in feeds would not occur at this dose level. However, an adverse effect is observed on chicks fed with fatty diet irradiated at 3 and 6 Mrad. It is suggested that a promising application of radiation treatment to the feeding of farm animals is irradiation at low dose levels of 0.5 approximately 0.6 Mrad. (author)

  20. Stock selection of high-dose-irradiation-resistant materials for filter press under high-dose irradiation operation

    International Nuclear Information System (INIS)

    Ishiyama, Shintaro; Minami, Mamoru; Hara, Kouji; Yamashita, Manabu

    2015-01-01

    In a volume reduction process for the decontamination of contained soil, the performance degradation of a filter press is expected owing to material deterioration under high-dose irradiation. Eleven-stock selection of candidate materials including polymers, fibers and rubbers for the filter press was conducted to achieve a high performance of volume reduction of contaminated soil and the following results were derived. Crude rubber and nylon were selected as prime candidates for packing, diaphragm and filter plate materials. Polyethylene was also selected as a prime candidate for the filter cloth material. (author)

  1. The Role of High Dose Interleukin-2 in the Era of Targeted Therapy.

    Science.gov (United States)

    Gills, Jessie; Parker, William P; Pate, Scott; Niu, Sida; Van Veldhuizen, Peter; Mirza, Moben; Holzbeierlein, Jeffery M; Lee, Eugene K

    2017-09-01

    We assessed survival outcomes following high dose interleukin-2 in a contemporary cohort of patients during the era of targeted agents. We retrospectively reviewed the records of patients with metastatic renal cell carcinoma treated with high dose interleukin-2 between July 2007 and September 2014. Clinicopathological data were abstracted and patient response to therapy was based on RECIST (Response Evaluation Criteria In Solid Tumors), version 1.1 criteria. The Kaplan-Meier method was used to estimate progression-free and overall survival in the entire cohort, the response to high dose interleukin-2 in regard to previous targeted agent therapy and the response to the targeted agent in relation to the response to high dose interleukin-2. We identified 92 patients, of whom 87 had documentation of a response to high dose interleukin-2. Median overall survival was 34.4 months from the initiation of high dose interleukin-2 therapy in the entire cohort. Patients who received targeted therapy before high dose interleukin-2 had overall survival (median 34.4 and 30.0 months, p = 0.88) and progression-free survival (median 1.5 and 1.7 months, p = 0.8) similar to those in patients who received no prior therapy, respectively. Additionally, patients with a complete or partial response to high dose interleukin-2 had similar outcomes for subsequent targeted agents compared to patients whose best response was stable or progressive disease (median overall survival 30.1 vs 25.4 months, p = 0.4). Our data demonstrate that patient responses to high dose interleukin-2 and to targeted agents before and after receiving high dose interleukin-2 are independent. As such, carefully selected patients should be offered high dose interleukin-2 for the possibility of a complete and durable response without the fear of limiting the treatment benefit of targeted agents. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Effective dose calculation in CT using high sensitivity TLDs

    International Nuclear Information System (INIS)

    Brady, Z.; Johnston, P.N.

    2010-01-01

    Full text: To determine the effective dose for common paediatric CT examinations using thermoluminescence dosimetry (TLD) mea surements. High sensitivity TLD chips (LiF:Mg,Cu,P, TLD-IOOH, Thermo Fisher Scientific, Waltham, MA) were calibrated on a linac at an energy of 6 MY. A calibration was also performed on a superricial X-ray unit at a kilovoltage energy to validate the megavoltage cali bration for the purpose of measuring doses in the diagnostic energy range. The dose variation across large organs was assessed and a methodology for TLD placement in a 10 year old anthropomorphic phantom developed. Effective dose was calculated from the TLD measured absorbed doses for typical CT examinations after correcting for the TLD energy response and taking into account differences in the mass energy absorption coefficients for different tissues and organs. Results Using new tissue weighting factors recommended in ICRP Publication 103, the effective dose for a CT brain examination on a 10 year old was 1.6 millisieverts (mSv), 4.9 mSv for a CT chest exa ination and 4.7 mSv for a CT abdomen/pelvis examination. These values are lower for the CT brain examination, higher for the CT chest examination and approximately the same for the CT abdomen/ pelvis examination when compared with effective doses calculated using ICRP Publication 60 tissue weighting factors. Conclusions High sensitivity TLDs calibrated with a radiotherapy linac are useful for measuring dose in the diagnostic energy range and overcome limitations of output reproducibility and uniformity asso ciated with traditional TLD calibration on CT scanners or beam quality matched diagnostic X-ray units.

  3. Cancer Control Related to Stimulation of Immunity by Low-Dose Radiation

    OpenAIRE

    Liu, Shu-Zheng

    2006-01-01

    Previous studies showed that low dose radiation (LDR) could stimulate the immune system in both animal and human populations. This paper reviews the present status of relevant research as support to the use of LDR in clinical practice for cancer prevention and treatment. It has been demonstrated that radiation-induced changes in immune activity follows an inverse J-shaped curve, i.e., low dose stimulation and high dose suppression. The stimulation of immunity by LDR concerns most anticancer p...

  4. HIGH-DOSE RATE BRACHYTHERAPY IN CARCINOMA CERVIX STAGE IIIB

    Directory of Open Access Journals (Sweden)

    Sathya Maruthavanan

    2016-07-01

    Full Text Available INTRODUCTION Radiotherapy is the standard treatment in locally advanced (IIB-IVA and early inoperable cases. The current standard of practice with curable intent is concurrent chemoradiation in which intracavitary brachytherapy is an integral component of radiotherapy. This study aims at assessing the efficacy of HDR ICBT (High-dose rate intracavitary brachytherapy in terms local response, normal tissue reactions, and feasibility. METHODS AND MATERIALS A total of 20 patients of stage IIIB cancer of the uterine cervix were enrolled in the study and were planned to receive concurrent chemotherapy weekly along with EBRT (external beam radiotherapy to a dose of 50 Gy/25 Fr. Suitability for ICBT was assessed at 40 Gy/20 Fr. 6/20 patients were suitable at 40 Gy and received HDR ICBT with a dose of 5.5 Gy to point A in 4 sessions (5.5 Gy/4 Fr. The remaining 14/20 patients completed 50 Gy and received HDR ICBT with a dose of 6 Gy to point A in 3 sessions (6 Gy/3 Fr. RESULTS A total of 66 intracavitary applications were done and only one application required dose modification due to high bladder dose, the pelvic control rate was 85% (17/20. 10% (2/20 had stable disease and 5% (1/20 had progressive disease at one year of follow up. When toxicity was considered only 15% developed grade I and grade II rectal complications. Patient compliance and acceptability was 100%. Patients were very comfortable with the short treatment time as compared with patients on LDR ICBT (low-dose rate intracavitary brachytherapy treatment interviewed during the same period. CONCLUSION This study proves that HDR brachytherapy is efficacious and feasible in carcinoma of cervix stage IIIB. It also proves that good dose distribution can be achieved with HDR intracavitary facility by the use of dose optimization. The short treatment time in HDR ICBT makes it possible to maintain this optimised dose distribution throughout the treatment providing a gain in the therapeutic ratio and

  5. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  6. Radiobiological problems concerning grazing animals following the Chernobyl accident

    International Nuclear Information System (INIS)

    Prister, B.S.; Lazarev, N.M.; Romanov, L.M.

    1997-01-01

    Chernobyl accident took place on April 26 1986, which was the beginning of the grazing season, when there was not enough fodder on the farms and the cattle was grazed on the open territory. Therefore grazing animal-breeding was the most radioactively affected branch. The consumption of contaminated fodder and surface contamination with radioactive precipitation caused the accumulation of considerable ingested doses in the organisms of animals (up to 1 GY). Radioactive damage caused to the thyroid by the selective accumulation of radioiodine (mainly 131 I) is of particular attention. Cumulative doses of thyroid irradiation in mammals were much higher than for the other organs. Thus, in cows during their grazing on the contaminated pastures outside 30-km zone the ratio of ingested doses of the thyroid and whole body was 130:1 and more, therefore, radiation effects could have a certain negative effect, concerning the agricultural animals in the zone of accidental release influence. Accumulated ingested doses in the thyroid of cows on the contaminated territory in a number of cases caused the complete destruction of the thyroid (doses above 600 Gy), which provided the loss of milk productivity and reproductive qualities of the animals. Lower doses caused the functional disturbances, which in most cases have been levelled during the years after the accident

  7. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  8. WE-E-BRE-04: Dual Focal Spot Dose Painting for Precision Preclinical Radiobiological Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, J; Lindsay, P [Princess Margaret Cancer Centre, Toronto (Canada); University of Toronto, Toronto (Canada); Jaffray, D [Princess Margaret Cancer Centre, Toronto (Canada); The Techna Institute for the Advancement of Technology for Health, Toronto (Canada)

    2014-06-15

    Purpose: Recent progress in small animal radiotherapy systems has provided the foundation for delivering the heterogeneous, millimeter scale dose distributions demanded by preclinical radiobiology investigations. Despite advances in preclinical dose planning, delivery of highly heterogeneous dose distributions is constrained by the fixed collimation systems and large x-ray focal spot common in small animal radiotherapy systems. This work proposes a dual focal spot dose optimization and delivery method with a large x-ray focal spot used to deliver homogeneous dose regions and a small focal spot to paint spatially heterogeneous dose regions. Methods: Two-dimensional dose kernels were measured for a 1 mm circular collimator with radiochromic film at 10 mm depth in a solid water phantom for the small and large x-ray focal spots on a recently developed small animal microirradiator. These kernels were used in an optimization framework which segmented a desired dose distribution into low- and high-spatial frequency regions for delivery by the large and small focal spot, respectively. For each region, the method determined an optimal set of stage positions and beam-on times. The method was demonstrated by optimizing a bullseye pattern consisting of 0.75 mm radius circular target and 0.5 and 1.0 mm wide rings alternating between 0 and 2 Gy. Results: Compared to a large focal spot technique, the dual focal spot technique improved the optimized dose distribution: 69.2% of the optimized dose was within 0.5 Gy of the intended dose for the large focal spot, compared to 80.6% for the dual focal spot method. The dual focal spot design required 14.0 minutes of optimization, and will require 178.3 minutes for automated delivery. Conclusion: The dual focal spot optimization and delivery framework is a novel option for delivering conformal and heterogeneous dose distributions at the preclinical level and provides a new experimental option for unique radiobiological investigations

  9. WE-E-BRE-04: Dual Focal Spot Dose Painting for Precision Preclinical Radiobiological Investigations

    International Nuclear Information System (INIS)

    Stewart, J; Lindsay, P; Jaffray, D

    2014-01-01

    Purpose: Recent progress in small animal radiotherapy systems has provided the foundation for delivering the heterogeneous, millimeter scale dose distributions demanded by preclinical radiobiology investigations. Despite advances in preclinical dose planning, delivery of highly heterogeneous dose distributions is constrained by the fixed collimation systems and large x-ray focal spot common in small animal radiotherapy systems. This work proposes a dual focal spot dose optimization and delivery method with a large x-ray focal spot used to deliver homogeneous dose regions and a small focal spot to paint spatially heterogeneous dose regions. Methods: Two-dimensional dose kernels were measured for a 1 mm circular collimator with radiochromic film at 10 mm depth in a solid water phantom for the small and large x-ray focal spots on a recently developed small animal microirradiator. These kernels were used in an optimization framework which segmented a desired dose distribution into low- and high-spatial frequency regions for delivery by the large and small focal spot, respectively. For each region, the method determined an optimal set of stage positions and beam-on times. The method was demonstrated by optimizing a bullseye pattern consisting of 0.75 mm radius circular target and 0.5 and 1.0 mm wide rings alternating between 0 and 2 Gy. Results: Compared to a large focal spot technique, the dual focal spot technique improved the optimized dose distribution: 69.2% of the optimized dose was within 0.5 Gy of the intended dose for the large focal spot, compared to 80.6% for the dual focal spot method. The dual focal spot design required 14.0 minutes of optimization, and will require 178.3 minutes for automated delivery. Conclusion: The dual focal spot optimization and delivery framework is a novel option for delivering conformal and heterogeneous dose distributions at the preclinical level and provides a new experimental option for unique radiobiological investigations

  10. Homologous tracheal transplantation with grafts previously exposed to high doses of gamma radiation in dogs without immunosuppressive agents

    International Nuclear Information System (INIS)

    Yokomise, Hiroyasu; Inui, Kenji; Kure, Toshio; Wada, Hiromi; Itomi, Shigeki

    1993-01-01

    The study was designed to determine whether previous high doses irradiation of gamma radiation would contribute to tracheal transplantation with no use of immunosuppressive agents. Twenty mongrel dogs were used as experimental animals. Five rings of thoracic tracheas, which were extracted from recipients, were exposed to 20000, 50000, or 100000 cGy in each 5 dogs. Five other non-irradiated dogs served as controls. Irradiated tracheal grafts were transplanted and covered with pedicled omentum. After transplantation, no immunosuppressive agents were given to dogs. All dogs in the control group died of tracheal stenosis due to graft-host rejection within one month. All but one long-term survivor died of tracheal stenosis, as well, in both the 20000 cGy and 50000 cGy groups. In the 100000 cGy group, grafts became viable in 4 dogs, and three of these survived one year or more. In conclusion, previous irradiation with high doses of 100000 cGy allowed homologous tracheal transplantation even when no immunosuppressive agents are given. (N.K.)

  11. Effect of Gamma-Oryzanol as Therapeutic Agent to Prevent Cardiorenal Metabolic Syndrome in Animals Submitted to High Sugar-Fat Diet

    Directory of Open Access Journals (Sweden)

    Fabiane Valentini Francisqueti

    2017-11-01

    Full Text Available Background: The high consumption of fat and sugar contributes to the development of obesity and co-morbidities, such as diabetes, and cardiovascular and kidney diseases. Different strategies have been used to prevent these diseases associated with obesity, such as changes in eating habits and/or the addition of dietary components with anti-inflammatory and anti-oxidant properties, such as gamma-oryzanol (γOz present mainly in bran layers and rice germ. Methods: Animals were randomly divided into four experimental groups and fed ad libitum for 20 weeks with control diet (C, n = 8, control diet + γOz (C + γOz, n = 8, high-sugar and high-fat diet (HSF, n = 8, and high-sugar and high-fat diet + γOz (HSF + γOz, n = 8. HSF groups also received water + sucrose (25%. The dose of γOz was added to diets to reach 0.5% of final concentration (w/w. Evaluation in animals included food and caloric intake, body weight, plasma glucose, insulin, triglycerides, uric acid, HOMA-IR, glomerular filtration rate, protein/creatinine ratio, systolic blood pressure, and Doppler echocardiographic. Results: Animals that consumed the HSF diet had weight gain compared to group C, increased insulin, HOMA, glucose and triglycerides, there were also atrial and ventricular structural alterations, deterioration of systolic and diastolic function, decreased glomerular filtration rate, and proteinuria. Gamma-oryzanol is significantly protective against effects on body weight, hypertriglyceridemia, renal damage, and against structural and functional alteration of the heart. Conclusion: Gamma-oryzanol shows potential as a therapeutic to prevent Cardiorenal Metabolic Syndrome.

  12. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    Science.gov (United States)

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  13. Widespread increases in malondialdehyde immunoreactivity in dopamine-rich and dopamine-poor regions of rat brain following multiple, high doses of methamphetamine.

    Directory of Open Access Journals (Sweden)

    Kristen Ashley eHorner

    2011-05-01

    Full Text Available Treatment with multiple high doses of methamphetamine (METH can induce oxidative damage, including dopamine (DA-mediated reactive oxygen species (ROS formation, which may contribute to the neurotoxic damage of monoamine neurons and long-term depletion of DA in the caudate putamen (CPu and substantia nigra pars compacta (SNpc. Malondialdehyde (MDA, a product of lipid peroxidation by ROS, is commonly used as a marker of oxidative damage and treatment with multiple high doses of METH increases MDA reactivity in the CPu of humans and experimental animals. Recent data indicate that MDA itself may contribute to the destruction of DA neurons, as MDA causes the accumulation of toxic intermediates of DA metabolism via its chemical modification of the enzymes necessary for the breakdown of DA. However, it has been shown that in human METH abusers there is also increased MDA reactivity in the frontal cortex, which receives relatively fewer DA afferents than the CPu. These data suggest that METH may induce neuronal damage regardless of the regional density of DA or origin of DA input. The goal of the current study was to examine the modification of proteins by MDA in the DA-rich nigrostriatal and mesoaccumbal systems, as well as the less DA-dense cortex and hippocampus following a neurotoxic regimen of METH treatment. Animals were treated with METH (10 mg/kg every 2h for 6h, sacrificed one week later, and examined using immunocytochemistry for changes in MDA-adducted proteins. Multiple, high doses of METH significantly increased MDA immunoreactivity (MDA-ir in the CPu, SNpc, cortex and hippocampus. Multiple METH administration also increased MDA-ir in the ventral tegmental area (VTA and nucleus accumbens (NAc. Our data indicate that multiple METH treatment can induce persistent and widespread neuronal damage that may not necessarily be limited to the nigrostriatal DA system.

  14. The Comparison of Two Types of Treatment (High Dose and Low Dose IVIG in Children with GBS in Mofid Hospital

    Directory of Open Access Journals (Sweden)

    Parvaneh Karim-Zadeh

    2003-12-01

    Full Text Available Objective: Acute inflammatory demyelinating peripheral neuropathy (Guillain-Barre-Syndrome is by far the most common cause of immune–mediated peripheral nerve disease in children and with the near disappearance of poliomyelitis, is responsible for the great majority of cases of acute flaccid paralysis. Several controlled studies have done with corticosteroids, plasma pheresis and IVIG in pediatric patients. IVIG treatment can be done in two types of treatment: 1- High dose that means 1gr/kg/day for 2 days. 2- Low dose that means 400mg/kg/day for 5 days. Several studies in other countries have shown faster rate of recovery in patients who received total dose of IVIG in 2 days as opposed to 5 days. Materials & Methods: Because we have not any study about this two types of treatment in IRAN we decided to comparison this two types of IVIG treatment. So the patients that referred to Mofid children hospital for weakness and we diagnosed GBS (with history, physical examination, laboratories and EMG-NCV are divided in two groups: 1- High dose IVIG treatment (experimental group. 2- Low dose IVIG treatment (control group Then the results evaluated. Results: Our findings included that in high dose IVIG therapy we have faster rate of recovery and the Hospital stay is shorter than low dose IVIG-therapy. Also in this type of treatment “because the patients cure faster” , so complications are decreased in them. In the group of high dose IVIG therapy, lower and upper extremities weakness decreased in time. Conclusion: We did not receive any relationship between side effects of drugs and the type of treatment. The relationship between high dose IVIG therapy and drug side effects was not significant.

  15. High-dose Sulbactam Treatment for Ventilator-Associated Pneumonia Caused by Carbapenem-Resistant

    Directory of Open Access Journals (Sweden)

    In Beom Jeong

    2016-11-01

    Full Text Available Background Several antibiotics can be used to treat ventilator-associated pneumonia caused by carbapenem-resistant A. baumannii (CRAB-VAP including high-dose sulbactam. However, the effectiveness of high-dose sulbactam therapy is not well known. We report our experience with high-dose sulbactam for treatment of CRAB-VAP. Methods Medical records of patients with CRAB-VAP who were given high-dose sulbactam between May 2013 and June 2015 were reviewed. Results Fifty-eight patients with CRAB-VAP were treated with high-dose sulbactam. The mean age was 72.0 ± 15.2 years, and the acute physiology and chronic health evaluation II (APACHE II score was 15.1 ± 5.10 at the time of CRAB-VAP diagnosis. Early clinical improvement was observed in 65.5% of patients, and 30-day mortality was 29.3%. Early clinical failure (odds ratio [OR]: 8.720, confidence interval [CI]: 1.346-56.484; p = 0.023 and APACHE II score ≥ 14 at CRAB-VAP diagnosis (OR: 10.934, CI: 1.047-114.148; p = 0.046 were associated with 30-day mortality. Conclusions High-dose sulbactam therapy may be effective for the treatment of CRAB-VAP. However, early clinical failure was observed in 35% of patients and was associated with poor outcome.

  16. Gadolinium-enhanced MR angiography (Gd-MRA) of thoracic vasculature in an animal model using double-dose gadolinium and quiet breathing

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Strouse, P.J. [Section of Pediatric Radiology, University of Michigan Health System, Ann Arbor (United States); Londy, F.J. [Dept. of Radiology, University of Michigan Hospitals, Ann Arbor, MI (United States); Wakefield, T.W. [Dept. of Surgery, Section of Vascular Surgery, University of Michigan Hospitals, Ann Arbor, MI (United States)

    2001-08-01

    Objective. To evaluate a gadolinium-enhanced MR angiography (Gd-MRA) imaging protocol for the assessment of thoracic vessels using double-dose gadolinium and quiet breathing. An animal model was used to simulate imaging in infants and young children. Material and methods. Six baboons (Papio anubis), mean weight 5.7 kg, were sedated and intubated. After the injection of double-dose Gd-DTPA (0.2 mmol/kg) through a peripheral vein, a coronal spoiled 3D gradient-echo volume acquisition was obtained during quiet breathing. Two radiologists reviewed the images for visualization of aortic arch, brachiocephalic vessel origins, pulmonary arteries (central, upper lobe and descending branches), and pulmonary veins (upper and lower). Results. Visualization was excellent for the aortic arch, brachiocephalic vessel origins, and pulmonary arteries, including the hilar branches. Visualization was excellent for the lower and right upper pulmonary veins and fair for the left upper pulmonary vein. There was excellent agreement between radiologists. Conclusion. Imaging of thoracic vessels with Gd-MRA using double gadolinium during quiet breathing was effective in our animal model. The advantages of this technique include a short imaging time and depiction of vascular segments - branches of pulmonary arteries and intraparenchymal segments of pulmonary veins - not optimally visualized with other non-invasive imaging techniques. (orig.)

  17. Gadolinium-enhanced MR angiography (Gd-MRA) of thoracic vasculature in an animal model using double-dose gadolinium and quiet breathing

    International Nuclear Information System (INIS)

    Hernandez, R.J.; Strouse, P.J.; Londy, F.J.; Wakefield, T.W.

    2001-01-01

    Objective. To evaluate a gadolinium-enhanced MR angiography (Gd-MRA) imaging protocol for the assessment of thoracic vessels using double-dose gadolinium and quiet breathing. An animal model was used to simulate imaging in infants and young children. Material and methods. Six baboons (Papio anubis), mean weight 5.7 kg, were sedated and intubated. After the injection of double-dose Gd-DTPA (0.2 mmol/kg) through a peripheral vein, a coronal spoiled 3D gradient-echo volume acquisition was obtained during quiet breathing. Two radiologists reviewed the images for visualization of aortic arch, brachiocephalic vessel origins, pulmonary arteries (central, upper lobe and descending branches), and pulmonary veins (upper and lower). Results. Visualization was excellent for the aortic arch, brachiocephalic vessel origins, and pulmonary arteries, including the hilar branches. Visualization was excellent for the lower and right upper pulmonary veins and fair for the left upper pulmonary vein. There was excellent agreement between radiologists. Conclusion. Imaging of thoracic vessels with Gd-MRA using double gadolinium during quiet breathing was effective in our animal model. The advantages of this technique include a short imaging time and depiction of vascular segments - branches of pulmonary arteries and intraparenchymal segments of pulmonary veins - not optimally visualized with other non-invasive imaging techniques. (orig.)

  18. Mutational influences of low-dose and high let ionizing radiation in drosophila melanogaster

    Science.gov (United States)

    Lei, Huang; Fanjun, Kong; Sun, Yeqing

    For cosmic environment consists of a varying kinds of radiation particles including high Z and energy ions which was charactered with low-dose and high RBE, it is important to determine the possible biofuctions of high LET radiation on human beings. To analyse the possible effectes of mutational influences of low-dose and high-LET ionizing radiation, wild fruit flies drosophila melanogaster were irradiated by 12C6+ ions in two LET levels (63.3 and 30 keV/µum) with different low doses from 2mGy to 2000mGy (2, 20, 200, 2000mGy) in HIRFL (Heavy ion radiation facility laboratory, lanzhou, China).In the same LET value group, the average polymorphic frequency was elevated along with adding doses of irradation, the frequency in 2000 mGy dose samples was significantly higher than other samples (p<0.01).These results suggest that genomic DNA sequence could be effected by low-dose and high-LET ionizing radiation, the irradiation dose is an important element in genomic mutation frequency origination.

  19. Gentamicin nephrotoxicity: Animal experimental correlate with human pharmacovigilance outcome

    Directory of Open Access Journals (Sweden)

    Olufunsho Awodele

    2015-04-01

    Full Text Available Background: National Agency for Food and Drugs Administration and Control (NAFDAC, which is responsible for pharmacovigilance activity in Nigeria, recently withdrew injection gentamicin 280 mg, used in the management of life-threatening and multidrug-resistant infections from circulation, due to reported toxicity. Thus, this study aimed to investigate the toxicity profile of the commonly used strengths (80 mg and 280 mg of gentamicin on kidney using animal models. Methods: Animals were divided into five groups of 16 rats each. For rats of groups 1 and 2, gentamicin (1.14 mg/kg each group was administered intramuscularly twice daily for 7 and 14 days, respectively, after which eight of them were sacrificed by cervical dislocation. Blood was collected via cardiac puncture and the kidneys were carefully removed and weighed immediately. The remaining eight animals were kept for reversibility study for another 7 and 14 days, respectively. For groups 3 and 4, gentamicin (4 mg/kg each group was administered as a single daily dose for 7 and 14 days, respectively, and eight animals from the groups were subjected to reversibility study for 7 and 14 days, respectively. Group 5, the control group animals, were given 10 ml/kg distilled water for 14 days. Histopathology of the kidneys, serum creatinine levels, and antioxidant enzyme activities were investigated. Results: Significant increase (p ≤ 0.001 in the level of creatinine of rats administered 4.0 mg/kg for 14 days was observed compared with all other groups. Significant (p ≤ 0.001 elevations in the lipid peroxidation in all gentamicin-administered animals and acute tubular necrosis in most of the gentamicin-administered animals were observed. Conclusion: Toxicity profile of gentamicin on the kidneys is dependent on both dose and duration of administration. The findings justify the decision made by NAFDAC to ban the use of high-dose inj. gentamicin 280 mg in Nigeria.

  20. Radio-sensitization of animals by bismuth; Radio sensibilisation de l'animal par le bismuth

    Energy Technology Data Exchange (ETDEWEB)

    Pierotti, T; Verain, A [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Digestive absorption of bismuth by animals leads to radio-sensitization. This effect is very marked when the X-rays used are centered on the absorption line of bismuth. This work has involved the use of more than 2000 C3H/JAX mice, and has shown that a maximum lethal effect, with respect to the standard, occurs for bismuth sub-nitrate doses of the order of 3 g/kg and for exposures of 700 R. For stronger or weaker doses, the sensitization effect is less marked. (authors) [French] L'absorption digestive de bismuth provoque une radiosensibilisation de l'animal. Celle-ci est nette quand le rayonnement X utilise est centre sur la raie d'absorption du bismuth. L'etude portant sur plus de 2000 souris C3H/JAX a montre une lethalite maximale par rapport aux temoins pour des doses de sous-nitrate de bismuth de l'ordre de 3 g/kg et pour des expositions de 700 R. Pour des doses plus fortes ou plus faibles, l'effet de sensibilisation est moins net. (auteurs)

  1. Reproductive function of animals exposed to low-dose external γ-radiation

    International Nuclear Information System (INIS)

    Izhevskij, P.V.; Krupitskaya, L.I.; Startsev, N.V.

    1993-01-01

    Chronic external γ-radiation effects on the reproductive function were simulated in male rats at doses equivalent to the dose obtained by the persons who participated in the liquidation of the Chernobyl poer plant accident aftereffects and by the population. The incidence of the pre-and postimplantation deaths was found increased in the progeny of males exposed to chronic external γ-irradiation at total doses of 158 and 237 Gy, though no strict dose dependence was observed

  2. Nonlinearity and thresholds in dose-response relationships for carcinogenicity due to sampling variation, logarithmic dose scaling, or small differences in individual susceptibility

    International Nuclear Information System (INIS)

    Lutz, W.K.; Gaylor, D.W.; Conolly, R.B.; Lutz, R.W.

    2005-01-01

    Nonlinear and threshold-like shapes of dose-response curves are often observed in tests for carcinogenicity. Here, we present three examples where an apparent threshold is spurious and can be misleading for low dose extrapolation and human cancer risk assessment. Case 1: For experiments that are not replicated, such as rodent bioassays for carcinogenicity, random variation can lead to misinterpretation of the result. This situation was simulated by 20 random binomial samplings of 50 animals per group, assuming a true linear dose response from 5% to 25% tumor incidence at arbitrary dose levels 0, 0.5, 1, 2, and 4. Linearity was suggested only by 8 of the 20 simulations. Four simulations did not reveal the carcinogenicity at all. Three exhibited thresholds, two showed a nonmonotonic behavior with a decrease at low dose, followed by a significant increase at high dose ('hormesis'). Case 2: Logarithmic representation of the dose axis transforms a straight line into a sublinear (up-bent) curve, which can be misinterpreted to indicate a threshold. This is most pronounced if the dose scale includes a wide low dose range. Linear regression of net tumor incidences and intersection with the dose axis results in an apparent threshold, even with an underlying true linear dose-incidence relationship. Case 3: Nonlinear shapes of dose-cancer incidence curves are rarely seen with epidemiological data in humans. The discrepancy to data in rodents may in part be explained by a wider span of individual susceptibilities for tumor induction in humans due to more diverse genetic background and modulation by co-carcinogenic lifestyle factors. Linear extrapolation of a human cancer risk could therefore be appropriate even if animal bioassays show nonlinearity

  3. Modality comparison for small animal radiotherapy: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova, Magdalena, E-mail: bazalova@stanford.edu; Nelson, Geoff; Noll, John M.; Graves, Edward E. [Department of Radiation Oncology, Molecular Imaging Program at Stanford, Stanford University, Stanford, California 94305 (United States)

    2014-01-15

    Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by

  4. Global dose to man from proposed NNTRP high altitude nuclear tests

    International Nuclear Information System (INIS)

    Peterson, K.R.

    1975-05-01

    Radionuclide measurements from past high altitude nuclear testing have enabled development of a model to estimate surface deposition and doses from 400 kt of fission products injected in winter within the Pacific Test Area at altitudes in excess of 50 km. The largest 30-year average dose to man is about 10 millirem and occurs at 30 0 to 50 0 N latitude. The principal contributor to this dose is external gamma radiation from gross fission products. Individual doses from 90 Sr via the forage-cow-milk pathway and 137 Cs via the pasture-meat pathway are about 1/5 the gross fission product doses. The global 30-year population dose is 3 x 10 7 person-rem, which compares with a 30-year natural background population dose of 1 X 10 10 person-rem. Due in large part to the global distribution of population, over 98 percent of the global person-rem from the proposed high altitude tests is received in the Northern Hemisphere, while about 75 percent of the total population dose occurs within the 30 0 --50 0 N latitude belt. Detonations in summer would decrease the global dose by about a factor of three. (U.S.)

  5. Dynamics of cytogenetic indexes of agriculture animals dwelling on the Semipalatinsk test site territory

    International Nuclear Information System (INIS)

    Mukusheva, M.K.; Sejsebaev, A.T.; Karabalin, B.K.; Tusupbaev, V.I.; Zhapbasov, R.Zh.

    2001-01-01

    Aim of the work is analysis of genetic processes taking place in the agricultural animal populations exposed to constant radiation due to increased radiation background in their dwelling places. By the cytogenetic methods the sheep, cattle and horses were examined. It was revealed cytogenetic effect manifested in form of a high genome genetic instability level for studied animals. It is suggested, that the effect is caused with low chronic ionizing radiation doses exposure on the agricultural animals somatic cells

  6. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    Science.gov (United States)

    Jaccard, Maud; Petersson, Kristoffer; Buchillier, Thierry; Germond, Jean-François; Durán, Maria Teresa; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François O; Bailat, Claude

    2017-02-01

    The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋ m ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋ p ) of up to 8 × 10 6 Gy/s. To do this, we evaluated the overall uncertainties in EBT3 film dosimetry as well as the energy and dose-rate dependence of their response. Our dosimetric system was composed of EBT3 Gafchromic films in combination with a flatbed scanner and was calibrated against an ionization chamber traceable to primary standard. All sources of uncertainties in EBT3 dosimetry were carefully analyzed using irradiations at a clinical radiotherapy linac. Energy dependence was investigated with the same machine by acquiring and comparing calibration curves for three different beam energies (4, 8 and 12 MeV), for doses between 0.25 and 30 Gy. Ḋ m dependence was studied at the clinical linac by changing the pulse repetition frequency (f) of the beam in order to vary Ḋ m between 0.55 and 4.40 Gy/min, while Ḋ p dependence was probed at the prototype machine for Ḋ p ranging from 7 × 10 3 to 8 × 10 6 Gy/s. Ḋ p dependence was first determined by studying the correlation between the dose measured by films and the charge of electrons measured at the exit of the machine by an induction torus. Furthermore, we compared doses from the films to independently calibrated thermo-luminescent dosimeters (TLD) that have been reported as being dose-rate independent up to such high dose-rates. We report that uncertainty below 4% (k = 2) can be achieved in the dose range between 3 and 17 Gy. Results also demonstrated that EBT3 films did not display any detectable energy dependence for electron beam energies between 4 and 12 MeV. No Ḋ m dependence was found either. In addition, we obtained excellent consistency between films and TLDs over the entire Ḋ p

  7. Oval pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    Hoogendijk, JE; Wokke, JHJ; de Visser, M

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Sis patients responded. Side effects

  8. Oral pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    van der Meulen, M. F.; Hoogendijk, J. E.; Wokke, J. H.; de Visser, M.

    2000-01-01

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Six patients responded. Side effects

  9. High-dose acetylcysteine in idiopathic pulmonary fibrosis

    NARCIS (Netherlands)

    Demedts, Maurits; Behr, Juergen; Buhl, Roland; Costabel, Ulrich; Dekhuijzen, Richard; Jansen, Henk M.; MacNee, William; Thomeer, Michiel; Wallaert, Benoit; Laurent, François; Nicholson, Andrew G.; Verbeken, Eric K.; Verschakelen, Johny; Flower, Christopher D. R.; Capron, Frédérique; Petruzzelli, Stefano; de Vuyst, Paul; van den Bosch, Jules M. M.; Rodriguez-Becerra, Eulogio; Corvasce, Giuseppina; Lankhorst, Ida; Sardina, Marco; Montanari, Mauro

    2005-01-01

    BACKGROUND Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily) added

  10. Regular self-microstructuring on CR39 using high UV laser dose

    International Nuclear Information System (INIS)

    Parvin, P.; Refahizadeh, M.; Mortazavi, S.Z.; Silakhori, K.; Mahdiloo, A.; Aghaii, P.

    2014-01-01

    The UV laser induced replicas in the form of self-lining microstructures are created by high dose (with high fluence) ArF laser irradiation on CR39. Microstructures as the self-induced contours, in the form of concentric circles, appear when the laser fluence is well above the ablation threshold. It leads to the regular periodic parallel lines, i.e. circles with large radii having spatial separation 100–200 nm and line width 300–600 nm, where the number of shots increases to achieve higher UV doses. The surface wettability is also investigated after laser texturing to exhibit that a notable hydrophilicity takes place at high doses.

  11. High-dose myeloablative versus conventional low-dose radioimmunotherapy (RIT) of mantle cell lymphoma (MCL) with the chimeric anti-CD20 antibody C2B8

    International Nuclear Information System (INIS)

    Behr, T.M.; Gotthardt, M.; Schipperm, M.L.; Gratz, S.; Behe, M.P.; Brittinger, G.; Woermann, B.; Becker, W.

    2002-01-01

    CD20 has been used as target molecule for low-dose as well as high-dose, myeloablative RIT of B-cell NHL. MCL is an especially aggressive, prognostically unfavorable form of B-cell NHL. The aim of this study was to investigate whether high-dose, myeloablative RIT with the 131 I-labeled chimeric anti-CD20 antibody C2B8 (rituxan, Mabthera, Roche) may be therapeutically more effective than conventional low-dose therapy in MCL. A total of twelve patients with chemorefractory or relapsed mantle cell lymphoma were studied so far (all of them having relapsed after high-dose chemotherapy, seven of them combined with 12 Gy TBI). A diagnostic-dosimetric study was performed with 10 mCi of 131 I-C2B8 at a protein dose of 2.5 mg/kg. In case of splenic pooling, the protein dose was increased until a more 'favorable' biodistribution was obtained. Therapy was performed with conventional (30-75 mCi; n=4) or myeloablative activities (261-515 mCi; n=8) of 131 I-C2B8 at the previously optimized protein dose, aiming at whole-body doses of ≤ 0.8 Gy (for low-dose RIT) or lung doses of ≤ 27 Gy (for high-dose RIT). Clinical follow-up was obtained for up to 42 months. Overall, in 11 patients the 2.5 mg/kg protein dose was used, whereas in one patient with marked splenomegaly, 10 mg/kg were necessary to overcome the splenic antigenic sink. In the high-dose patients, non-hematologic toxicity was restricted to mild to moderate nausea, fever, transient bilirubin or liver enzyme elevations. Despite thyroid blocking, 6/8 high-dose (in contrast to 0/4 low-dose) patients developed hypothyroidism, requiring thyroxine substitution at 6-18 months after RIT. The response rate in the low-dose arm was only 1(PR)/4, whereas 7/8 high-dose patients experienced complete and the remainder a partial remission. 6 high-dose patients are still in CR (one of them relapsed locally at 3 months, one systemically at 26 months after RIT), and 7 are still alive for up to 42+ months. In contrast to low-dose therapy

  12. Regulatory Forum Opinion Piece*: Retrospective Evaluation of Doses in the 26-week Tg.rasH2 Mice Carcinogenicity Studies: Recommendation to Eliminate High Doses at Maximum Tolerated Dose (MTD) in Future Studies.

    Science.gov (United States)

    Paranjpe, Madhav G; Denton, Melissa D; Vidmar, Tom J; Elbekai, Reem H

    2015-07-01

    High doses in Tg.rasH2 carcinogenicity studies are usually set at the maximum tolerated dose (MTD), although this dose selection strategy has not been critically evaluated. We analyzed the body weight gains (BWGs), mortality, and tumor response in control and treated groups of 29 Tg.rasH2 studies conducted at BioReliance. Based on our analysis, it is evident that the MTD was exceeded at the high and/or mid-doses in several studies. The incidence of tumors in high doses was lower when compared to the low and mid-doses of both sexes. Thus, we recommend that the high dose in male mice should not exceed one-half of the estimated MTD (EMTD), as it is currently chosen, and the next dose should be one-fourth of the EMTD. Because females were less sensitive to decrements in BWG, the high dose in female mice should not exceed two-third of EMTD and the next dose group should be one-third of EMTD. If needed, a third dose group should be set at one-eighth EMTD in males and one-sixth EMTD in females. In addition, for compounds that do not show toxicity in the range finding studies, a limit dose should be applied for the 26-week carcinogenicity studies. © 2014 by The Author(s).

  13. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  14. Feasibility of small animal cranial irradiation with the microRT system

    International Nuclear Information System (INIS)

    Kiehl, Erich L.; Stojadinovic, Strahinja; Malinowski, Kathleen T.; Limbrick, David; Jost, Sarah C.; Garbow, Joel R.; Rubin, Joshua B.; Deasy, Joseph O.; Khullar, Divya; Izaguirre, Enrique W.; Parikh, Parag J.; Low, Daniel A.; Hope, Andrew J.

    2008-01-01

    Purpose: To develop and validate methods for small-animal CNS radiotherapy using the microRT system. Materials and Methods: A custom head immobilizer was designed and built to integrate with a pre-existing microRT animal couch. The Delrin couch-immobilizer assembly, compatible with multiple imaging modalities (CT, microCT, microMR, microPET, microSPECT, optical), was first imaged via CT in order to verify the safety and reproducibility of the immobilization method. Once verified, the subject animals were CT-scanned while positioned within the couch-immobilizer assembly for treatment planning purposes. The resultant images were then imported into CERR, an in-house-developed research treatment planning system, and registered to the microRTP treatment planning space using rigid registration. The targeted brain was then contoured and conformal radiotherapy plans were constructed for two separate studies: (1) a whole-brain irradiation comprised of two lateral beams at the 90 degree sign and 270 degree sign microRT treatment positions and (2) a hemispheric (left-brain) irradiation comprised of a single A-P vertex beam at the 0 degree sign microRT treatment position. During treatment, subject animals (n=48) were positioned to the CERR-generated treatment coordinates using the three-axis microRT motor positioning system and were irradiated using a clinical Ir-192 high-dose-rate remote after-loading system. The radiation treatment course consisted of 5 Gy fractions, 3 days per week. 90% of the subjects received a total dose of 30 Gy and 10% received a dose of 60 Gy. Results: Image analysis verified the safety and reproducibility of the immobilizer. CT scans generated from repeated reloading and repositioning of the same subject animal in the couch-immobilizer assembly were fused to a baseline CT. The resultant analysis revealed a 0.09 mm average, center-of-mass translocation and negligible volumetric error in the contoured, murine brain. The experimental use of the head

  15. Novel animal model for Achilles tendinopathy: Controlled experimental study of serial injections of collagenase in rabbits.

    Science.gov (United States)

    de Cesar Netto, Cesar; Godoy-Santos, Alexandre Leme; Augusto Pontin, Pedro; Natalino, Renato Jose Mendonça; Pereira, Cesar Augusto Martins; Lima, Francisco Diego de Oliveira; da Fonseca, Lucas Furtado; Staggers, Jackson Rucker; Cavinatto, Leonardo Muntada; Schon, Lew Charles; de Camargo, Olavo Pires; Fernandes, Túlio Diniz

    2018-01-01

    Our goal was to develop a novel technique for inducing Achilles tendinopathy in animal models which more accurately represents the progressive histological and biomechanical characteristic of chronic Achilles tendinopathy in humans. In this animal research study, forty-five rabbits were randomly assigned to three groups and given bilateral Achilles injections. Low dose (LD group) (n = 18) underwent a novel technique with three low-dose (0.1mg) injections of collagenase that were separated by two weeks, the high dose group (HD) (n = 18) underwent traditional single high-dose (0.3mg) injections, and the third group were controls (n = 9). Six rabbits were sacrificed from each experimental group (LD and HD) at 10, 12 and 16 weeks. Control animals were sacrificed after 16 weeks. Histological and biomechanical properties were then compared in all three groups. At 10 weeks, Bonar score and tendon cross sectional area was highest in HD group, with impaired biomechanical properties compared to LD group. At 12 weeks, Bonar score was higher in LD group, with similar biomechanical findings when compared to HD group. After 16 weeks, Bonar score was significantly increased for both LD group (11,8±2,28) and HD group (5,6±2,51), when compared to controls (2±0,76). LD group showed more pronounced histological and biomechanical findings, including cross sectional area of the tendon, Young's modulus, yield stress and ultimate tensile strength. In conclusion, Achilles tendinopathy in animal models that were induced by serial injections of low-dose collagenase showed more pronounced histological and biomechanical findings after 16 weeks than traditional techniques, mimicking better the progressive and chronic characteristic of the tendinopathy in humans.

  16. Dosimetry of an animal irradiation system

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Nelson M.; Funari, Ana P.; Miranda, Jurandir T.; Napolitano, Celia M.; Goncalves, Josemary A.C.; Bueno, Carmen C.; Mathor, Monica B., E-mail: nelsonnininho@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Radiation therapy uses ionizing radiation for cancer treatment, but its effectiveness may be limited by the consequent appearance of radiodermatitis. This problem may present several degrees: the highest among them is radionecrosis. Therefore, a model of study for the animal irradiation system (AIS) was built, generating radionecrosis on rat backs. The AIS is comprised by: a) a shield between the {sup 60}Co irradiator metallic guide and the animal immobilizer (AI), with holes exposing the rat skin; b) a shield on the AI posterior part and (c) the AIS angle. The doses were measured with alanine pellets in seven positions (two external and five internal) and different heights, in axial planes along the AI, and irradiated with 85 Gy. The similarity in the geometry of the AIs made it possible to relate the doses of positions 1-7 with the same height among the AISs. The AISs equidistance to the source allowed simultaneous animal exposure. Minimizing the shielding and maximizing the angles among the AISs provided average doses almost identical in position 1. A small variation among the mean doses for each of the AISs enabled to replace them by the average doses of the three AISs at position 1. Shields allowed the attenuation of the uncertainties in the alanine pellet in the AI, reduction of the exposure time without compromising rat security and the rise of the dose in measurement positions 1 and 2. The maximization of the angles among the AISs reduced the shielding secondary radiation contribution. (author)

  17. Dosimetry of an animal irradiation system

    International Nuclear Information System (INIS)

    Alves, Nelson M.; Funari, Ana P.; Miranda, Jurandir T.; Napolitano, Celia M.; Goncalves, Josemary A.C.; Bueno, Carmen C.; Mathor, Monica B.

    2015-01-01

    Radiation therapy uses ionizing radiation for cancer treatment, but its effectiveness may be limited by the consequent appearance of radiodermatitis. This problem may present several degrees: the highest among them is radionecrosis. Therefore, a model of study for the animal irradiation system (AIS) was built, generating radionecrosis on rat backs. The AIS is comprised by: a) a shield between the 60 Co irradiator metallic guide and the animal immobilizer (AI), with holes exposing the rat skin; b) a shield on the AI posterior part and (c) the AIS angle. The doses were measured with alanine pellets in seven positions (two external and five internal) and different heights, in axial planes along the AI, and irradiated with 85 Gy. The similarity in the geometry of the AIs made it possible to relate the doses of positions 1-7 with the same height among the AISs. The AISs equidistance to the source allowed simultaneous animal exposure. Minimizing the shielding and maximizing the angles among the AISs provided average doses almost identical in position 1. A small variation among the mean doses for each of the AISs enabled to replace them by the average doses of the three AISs at position 1. Shields allowed the attenuation of the uncertainties in the alanine pellet in the AI, reduction of the exposure time without compromising rat security and the rise of the dose in measurement positions 1 and 2. The maximization of the angles among the AISs reduced the shielding secondary radiation contribution. (author)

  18. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  19. Moderate- vs high-dose methadone in the treatment of opioid dependence: a randomized trial.

    Science.gov (United States)

    Strain, E C; Bigelow, G E; Liebson, I A; Stitzer, M L

    1999-03-17

    Methadone hydrochloride treatment is the most common pharmacological intervention for opioid dependence, and recent interest has focused on expanding methadone treatment availability beyond traditional specially licensed clinics. However, despite recommendations regarding effective dosing of methadone, controlled clinical trials of higher-dose methadone have not been conducted. To compare the relative clinical efficacy of moderate- vs high-dose methadone in the treatment of opioid dependence. A 40-week randomized, double-blind clinical trial starting in June 1992 and ending in October 1995. Outpatient substance abuse treatment research clinic at the Johns Hopkins University Bayview Campus, Baltimore, Md. One hundred ninety-two eligible clinic patients. Daily oral methadone hydrochloride in the dose range of 40 to 50 mg (n = 97) or 80 to 100 mg (n = 95), with concurrent substance abuse counseling. Opioid-positive urinalysis results and retention in treatment. By intent-to-treat analysis through week 30 patients in the high-dose group had significantly lower rates of opioid-positive urine samples compared with patients in the moderate-dose group (53.0% [95% confidence interval [CI], 46.9%-59.2%] vs 61.9% [95% CI, 55.9%-68.0%]; P = .047. These differences persisted during withdrawal from methadone. Through day 210 no significant difference was evident between dose groups in treatment retention (high-dose group mean retention, 159 days; moderate-dose group mean retention, 157 days). Nineteen (33%) of 57 patients in the high-dose group and 11 (20%) of 54 patients in the moderate-dose group completed detoxification. Both moderate- and high-dose methadone treatment resulted in decreased illicit opioid use during methadone maintenance and detoxification. The high-dose group had significantly greater decreases in illicit opioid use.

  20. High dose vitamin D may improve lower urinary tract symptoms in postmenopausal women.

    Science.gov (United States)

    Oberg, Johanna; Verelst, Margareta; Jorde, Rolf; Cashman, Kevin; Grimnes, Guri

    2017-10-01

    Lower urinary tract symptoms (LUTS) are common in postmenopausal women, and have been reported inversely associated with vitamin D intake and serum 25-hydroxyvitamin D (25(OH)D) levels. The aim of this study was to investigate if high dose vitamin D supplementation would affect LUTS in comparison to standard dose. In a randomized controlled study including 297 postmenopausal women with low bone mineral density, the participants were allocated to receive capsules of 20 000IU of vitamin D 3 twice a week (high dose group) or similar looking placebo (standard dose group). In addition, all the participants received 1g of calcium and 800IU of vitamin D daily. A validated questionnaire regarding LUTS was filled in at baseline and after 12 months. At baseline, 76 women in the high dose group and 82 in the standard dose group reported any LUTS. Levels of serum 25(OH)D increased significantly more in the high dose group (from 64.7 to 164.1nmol/l compared to from 64.1 to 81.8nmol/l, p<0.01). No differences between the groups were seen regarding change in LUTS except for a statistically significant reduction in the reported severity of urine incontinence in the high dose group as compared to the standard dose group after one year (p<0.05). The results need confirmation in a study specifically designed for this purpose. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Radiation processing and high-dose dosimetry at ANSTO

    International Nuclear Information System (INIS)

    Gant, G.J.; Saunders, M.; Banos, C.; Mo, L.; Davies, J.; Evans, O.

    2001-01-01

    The Radiation Technology group at ANSTO is part of the Physics Division and provides services and advice in the areas of gamma irradiation and high-dose dosimetry. ANSTO's irradiation facilities are designed for maximum dose uniformity and provide a precision irradiation service unique in Australia. Radiation Technology makes and sells reference and transfer standard dosimeters which are purchased by users and suppliers of commercial irradiation services in Australia and the Asia-Pacific region. A calibration service is also provided for dosimeters purchased from other suppliers

  2. Safety of high-dose daptomycin in patients with severe renal impairment

    Directory of Open Access Journals (Sweden)

    Tai CH

    2018-03-01

    Full Text Available Chih-Hsun Tai,1 Chi-Hao Shao,2 Chen-You Chen,2 Shu-Wen Lin,1–3 Chien-Chih Wu1,2 1Department of Pharmacy, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan; 2School of Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan; 3Graduate Institute of Clinical Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan Background: Treatment options are limited for infections due to multidrug-resistant Gram-positive pathogens. Daptomycin is a lipopeptide antibiotic with concentration-dependent killing characteristic and dose-dependent post-antibiotic effect. To achieve optimized pharmacodynamic effect, some experts advocated using a high dose of daptomycin (≥9 mg/kg for severe infections. However, the safety of high-dose therapy in patients with renal impairment remains unknown. This study was aimed to evaluate the safety of daptomycin in patients with severe renal impairment. Methods: This was a retrospective study performed by reviewing electronic medical records. Patients with severe renal impairment who were treated with daptomycin in a tertiary teaching hospital between January 1, 2013, and June 30, 2016, were included for evaluation. The incidence rates of creatine kinase (CK elevation between high-dose (≥9 mg/kg and standard-dose (<9 mg/kg groups were compared. Results: Overall, 164 patients met the inclusion criteria, and 114 (69.5% of them were on renal replacement therapy. Vancomycin-resistant enterococci were the most common pathogens (61.3% of the patients with documented pathogens. The treatment success rate was 51.6% in the 91 patients with bacteremia. The average dose of daptomycin was 8.0±2.3 mg/kg, and 37 (22.6% patients received ≥9 mg/kg. CK levels were followed in 108 (65.9% patients. Significantly higher incidence of CK elevation was found in the high-dose group compared with that in the standard-dose group (10.8% vs 1.6%, P<0.05. Moreover

  3. Radiation dose estimates for adults and newborns from tungsten-178: based on distribution data in adult and infant animals

    International Nuclear Information System (INIS)

    Wiles, H.; Lacy, J.; LeBlanc, A.; Bricker, J.; Watson, E.; Stabin, M.

    1987-01-01

    Biodistribution and retention of tungsten-178 ( 178 W) were studied in adult and infant animals in order to extrapolate radiation dose estimates to human newborns and adults. Whole body retention and organ distribution of 178 W were determined at 0.5, 2, 8, 24 and 48 hours after blood-pool injection in infant and adult rats. Percent whole body retention and percent organ uptake per gram of tissue were higher in infant than adult rats at each time interval. When extrapolated to humans on the basis of percent injected activity kilogram per gram, most organs, except bone and kidney, showed higher uptake in newborns than adults. Total body radiation dose estimates for humans from 178 w based on these data were: 0.93 mGy/MBq (3.4 rad/mCi) for newborns and 0.024 mGy/MBq (0.089 rad/mCi) for adults. 13 refs.; 5 tabs

  4. Non-linear dose-response of aluminium hydroxide adjuvant particles: Selective low dose neurotoxicity

    International Nuclear Information System (INIS)

    Crépeaux, Guillemette; Eidi, Housam; David, Marie-Odile; Baba-Amer, Yasmine; Tzavara, Eleni; Giros, Bruno; Authier, François-Jérôme; Exley, Christopher; Shaw, Christopher A.; Cadusseau, Josette

    2017-01-01

    Aluminium (Al) oxyhydroxide (Alhydrogel ® ), the main adjuvant licensed for human and animal vaccines, consists of primary nanoparticles that spontaneously agglomerate. Concerns about its safety emerged following recognition of its unexpectedly long-lasting biopersistence within immune cells in some individuals, and reports of chronic fatigue syndrome, cognitive dysfunction, myalgia, dysautonomia and autoimmune/inflammatory features temporally linked to multiple Al-containing vaccine administrations. Mouse experiments have documented its capture and slow transportation by monocyte-lineage cells from the injected muscle to lymphoid organs and eventually the brain. The present study aimed at evaluating mouse brain function and Al concentration 180 days after injection of various doses of Alhydrogel ® (200, 400 and 800 μg Al/kg of body weight) in the tibialis anterior muscle in adult female CD1 mice. Cognitive and motor performances were assessed by 8 validated tests, microglial activation by Iba-1 immunohistochemistry, and Al level by graphite furnace atomic absorption spectroscopy. An unusual neuro-toxicological pattern limited to a low dose of Alhydrogel ® was observed. Neurobehavioural changes, including decreased activity levels and altered anxiety-like behaviour, were observed compared to controls in animals exposed to 200 μg Al/kg but not at 400 and 800 μg Al/kg. Consistently, microglial number appeared increased in the ventral forebrain of the 200 μg Al/kg group. Cerebral Al levels were selectively increased in animals exposed to the lowest dose, while muscle granulomas had almost Completely disappeared at 6 months in these animals. We conclude that Alhydrogel ® injected at low dose in mouse muscle may selectively induce long-term Al cerebral accumulation and neurotoxic effects. To explain this unexpected result, an avenue that could be explored in the future relates to the adjuvant size since the injected suspensions corresponding to the lowest dose

  5. Unusual complication and successful high-dose chemotherapy ...

    African Journals Online (AJOL)

    ... treated with high-dose chemotherapy in our institution, complicated by unusual bilateral renal vein tumour thrombi and tumour lysis syndrome. We believe this unique case highlights the need for early recognition of current and potential complications on staging computed tomography imaging, as well as successful use of ...

  6. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.; Castro, J.R.; Chen, G.T.Y.; Collier, J.M.; Cartigny, A.; Blakely, E.A.; Lyman, J.T.; Zink, S.R.

    1985-02-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons.

  7. Precision, high dose radiotherapy: helium ion treatment of uveal melanoma

    International Nuclear Information System (INIS)

    Saunders, W.M.; Char, D.H.; Quivey, J.M.

    1985-01-01

    The authors report on 75 patients with uveal melanoma who were treated by placing the Bragg peak of a helium ion beam over the tumor volume. The technique localizes the high dose region very tightly around the tumor volume. This allows critical structures, such as the optic disc and the macula, to be excluded from the high dose region as long as they are 3 to 4 mm away from the edge of the tumor. Careful attention to tumor localization, treatment planning, patient immobilization and treatment verification is required. With a mean follow-up of 22 months (3 to 60 months) the authors have had only five patients with a local recurrence, all of whom were salvaged with another treatment. Pretreatment visual acuity has generally been preserved as long as the tumor edge is at least 4 mm away from the macula and optic disc. The only serious complication to date has been an 18% incidence of neovascular glaucoma in the patients treated at our highest dose level. Clinical results and details of the technique are presented to illustrate potential clinical precision in administering high dose radiotherapy with charged particles such as helium ions or protons

  8. Low dose rate and high dose rate intracavitary treatment for cervical cancer

    International Nuclear Information System (INIS)

    Hareyama, Masato; Oouchi, Atsushi; Shidou, Mitsuo

    1997-01-01

    From 1984 through 1993, 144 previous untreated patients with carcinoma of uterine cervix were treated with either low dose rate 137 Cs therapy (LDR) or high dose rate 60 Co therapy (HDR). The local failure rates for more than 2-years for the primary lesions were 11.8% (8 of 63 patients) for LDR and 18.0% (11 of 61 patients). Rectal complication rates were significantly lower for HDR versus LDR (14.3% VS. 32.8%. p<0.01). Also, bladder complication rates were significantly lower for HDR versus LDR (0% VS. 10.4%, p<0.005). Treatment results in term of local control were equivalent for HDR and LDR treatment. However, the incidence of complications was higher for the LDR group than for the HDR group. (author)

  9. Health effect of low dose/low dose rate radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji

    2012-01-01

    The clarified and non-clarified scientific knowledge is discussed to consider the cause of confusion of explanation of the title subject. The low dose is defined roughly lower than 200 mGy and low dose rate, 0.05 mGy/min. The health effect is evaluated from 2 aspects of clinical symptom/radiation hazard protection. In the clinical aspect, the effect is classified in physical (early and late) and genetic ones, and is classified in stochastic (no threshold value, TV) and deterministic (with TV) ones from the radioprotection aspect. Although the absence of TV in the carcinogenic and genetic effects has not been proved, ICRP employs the stochastic standpoint from the safety aspect for radioprotection. The lowest human TV known now is 100 mGy, meaning that human deterministic effect would not be generated below this dose. Genetic deterministic effect can be observable only in animal experiments. These facts suggest that the practical risk of exposure to <100 mGy in human is the carcinogenesis. The relationship between carcinogenic risk in A-bomb survivors and their exposed dose are found fitted to the linear no TV model, but the epidemiologic data, because of restriction of subject number analyzed, do not always mean that the model is applicable even below the dose <100 mGy. This would be one of confusing causes in explanation: no carcinogenic risk at <100 mGy or risk linear to dose even at <100 mGy, neither of which is scientifically conclusive at present. Also mentioned is the scarce risk of cancer in residents living in the high background radiation regions in the world in comparison with that in the A-bomb survivors exposed to the chronic or acute low dose/dose rate. Molecular events are explained for the low-dose radiation-induced DNA damage and its repair, gene mutation and chromosome aberration, hypothesis of carcinogenesis by mutation, and non-targeting effect of radiation (bystander effect and gene instability). Further researches to elucidate the low dose

  10. Dimethyl sulfoxyde diethyl fumarate solution for high dose dosimetry

    International Nuclear Information System (INIS)

    Al-Kassiri, H.; Kattan, M.; Daher, Y.

    2007-06-01

    Dosimetric characterization of diethyl fumarate DEF in dimethyl sulfoxyde DMSO solution has been studied spectrophotometrically for possible application at high dose radiation dosimetry in the range (0-225 kGy). The absorption spectra of irradiated solution showed broad absorption bands between (325-400 nm) with a shoulder at 332 nm. The absorption increases as the dose is increased. Absorbance at 332 nm were measured and plotted against absorbed dose. Linear relationship and good response were found between absorbed dose and absorbance of 20% DEF concentration in the range (0-225 kGy) at the wave length, and linearity up to 250 kGy of absorbance at 332 nm .Good dose rate independence was observed in the range (14-33 kGy/h). The effect of post irradiation storage in darkness and indirect daylight conditions were not found to influence the absorption up to 700 h after irradiation. The effect of irradiation temperature within the range (0 to 60 centigrade degree) on the dosimetry performance was discussed.(author)

  11. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  12. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  13. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tome, Wolfgang A. [Department of Human Oncology, University of Wisconsin-Madison, WI, 53792 (United States); Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC 3002 (Australia) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Human Oncology, University of Wisconsin-Madison, WI 53792 (United States); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia) and Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Einstein Institute of Oncophysics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York 10461 (United States) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2012-08-15

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  14. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tomé, Wolfgang A.

    2012-01-01

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed “Super Sampling” involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  15. The influence of high doses of radiation in citrine stones

    International Nuclear Information System (INIS)

    Teixeira, M. I.; Caldas, L. V. E.

    2014-08-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  16. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  17. Review of high-dose intravenous vitamin C as an anticancer agent.

    Science.gov (United States)

    Wilson, Michelle K; Baguley, Bruce C; Wall, Clare; Jameson, Michael B; Findlay, Michael P

    2014-03-01

    In the 1970s, Pauling and Cameron reported increased survival of patients with advanced cancer treated with high-dose intravenous (IV) vitamin C (L-ascorbate, ascorbic acid). These studies were criticized for their retrospective nature and lack of standardization of key prognostic factors including performance status. Subsequently, several well-designed randomized controlled trials failed to demonstrate a significant survival benefit, although these trials used high-dose oral vitamin C. Marked differences are now recognized in the pharmacokinetics of vitamin C with oral and IV administration, opening the issue of therapeutic efficacy to question. In vitro evidence suggests that vitamin C functions at low concentrations as an antioxidant but may have pro-oxidant activity at high concentrations. The mechanism of its pro-oxidant action is not fully understood, and both intra- and extracellular mechanisms that generate hydrogen peroxide have been proposed. It remains to be proven whether vitamin C-induced reactive oxygen species occur in vivo and, if so, whether this will translate to a clinical benefit. Current clinical evidence for a therapeutic effect of high-dose IV vitamin C is ambiguous, being based on case series. The interpretation and validation of these studies is hindered by limited correlation of plasma vitamin C concentrations with response. The methodology exists to determine if there is a role for high-dose IV vitamin C in the treatment of cancer, but the limited understanding of its pharmacodynamic properties makes this challenging. Currently, the use of high-dose IV vitamin C cannot be recommended outside of a clinical trial. © 2014 Wiley Publishing Asia Pty Ltd.

  18. Conventional-Dose versus High-Dose Chemotherapy for Relapsed Germ Cell Tumors

    Directory of Open Access Journals (Sweden)

    Deaglan J. McHugh

    2018-01-01

    Full Text Available The majority of metastatic germ cell tumors (GCTs are cured with cisplatin-based chemotherapy, but 20–30% of patients will relapse after first-line chemotherapy and require additional salvage strategies. The two major salvage approaches in this scenario are high-dose chemotherapy (HDCT with autologous stem cell transplant (ASCT or conventional-dose chemotherapy (CDCT. Both CDCT and HDCT have curative potential in the management of relapsed/refractory GCT. However, due to a lack of conclusive randomized trials, it remains unknown whether sequential HDCT or CDCT represents the optimal initial salvage approach, with practice varying between tertiary institutions. This represents the most pressing question remaining for defining GCT treatment standards and optimizing outcomes. The authors review prognostic factors in the initial salvage setting as well as the major studies assessing the efficacy of CDCT, HDCT, or both, describing the strengths and weaknesses that formed the rationale behind the ongoing international phase III “TIGER” trial.

  19. Radioprotection of salivary glands by S-2-(3-aminopropylamino)-ethylphosphorothioic (amifostine) obtained in a rabbit animal model

    Energy Technology Data Exchange (ETDEWEB)

    Bohuslavizki, Karl H; Klutmann, Susanne; Jenicke, Lars; Brenner, Winfried; Feyerabend, Bernd; Henze, Eberhard; Clausen, Malte

    1999-08-01

    Background: Impairment of salivary gland function following high-dose radioiodine treatment (HDRIT) is a well-recognized side effect of the treatment. Because differentiated thyroid cancer has an excellent prognosis, reduction of long-term side-effects is mandatory. Therefore, the aim of this study was to investigate the radioprotective effect of amifostine in a rabbit animal model. Methods: Salivary gland scintigraphy was performed in a total of 16 New Zealand White rabbits. Uptake of {sup 99m}Tc-pertechnetate was calculated in percentage of injected activity as a quantitative measure of both salivary gland and thyroid function. Reproducibility of salivary gland scintigraphy was evaluated in one rabbit without any intervention. Fifteen rabbits were studied prior to and up to 6 months after high-dose radioiodine treatment applying 2 GBq {sup 131}I. Ten animals received 200 mg/kg amifostine prior to high-dose radioiodine therapy, and 5 served as controls. Salivary glands were examined histopathologically. Results: Variation coefficient of parenchymal function was less than 3.8% in salivary glands. Prior to HDRIT, thyroid uptake was 0.417 {+-} 0.373% and 0.421 {+-} 0.241% in control and amifostine-treated rabbits, respectively. Four weeks after HDRIT, complete ablation of the thyroid was achieved in both groups. Prior to HDRIT, uptake of {sup 99m}Tc-pertechnetate in salivary glands of five control rabbits was not significantly different from ten amifostine-treated rabbits. In control rabbits 6 months after HDRIT, parenchymal function was reduced significantly (p < 0.0001) by 75.3 {+-} 5.3% and 53.6 {+-} 17.4% in parotid and submandibular glands, respectively. In contrast, in amifostine-treated rabbits, parenchymal function was reduced by 10.6 {+-} 3.4% and 6.5 {+-} 4.3% (p > 0.05) in parotid and submandibular glands, respectively. Histopathologically, marked lipomatosis was observed in control animals but was negligible in amifostine-treated animals. Conclusion

  20. Low- and high-dose laser irradiation effects on cell migration and destruction

    Science.gov (United States)

    Layton, Elivia; Gallagher, Kyra A.; Zukerman, Sara; Stevens, Brianna; Zhou, Feifan; Liu, Hong; Chen, Wei R.

    2018-02-01

    Metastases are the cause of more than 90 percent of cancer-related deaths. Current treatment methods, including chemotherapy, radiation, and surgery, fail to target the metastases effectively. One potential treatment for metastatic cancer is laser immunotherapy (LIT). LIT combines the use of a photothermal laser with an immunoadjuvant, Glycated Chitosan (GC). GC combined with single-walled carbon nanotubes (SWNTs) has proven to be a viable alternative to traditional cancer treatment methods, when under irradiation of laser with appropriate wavelength. In this study, the effects of low dose and high dose laser irradiation on metastatic pancreatic cancer cell migration were observed. It was found that low dose irradiation increased the migration rate, but the high dose irradiation significantly decreased the migration rate of the cancer cells. When using LIT, the goal is to kill tumor cells and to prompt the correct immune response. If the tumor were irradiated with a low dose, it would promote metastasis. If the dose of irradiation were too high, it would destroy the entire tumor and the immune response would not recognize the tumor. Therefore, the laser dose plays an important role in LIT, particularly when using SWNT as light absorbing agent. Our results from this study will delineate the optimal laser irradiation dose for destroying tumor cells and at the same time preserve and release tumor antigens as a precursor of antitumor immune response.

  1. Dose Determination of Activated Charcoal in Management of ...

    African Journals Online (AJOL)

    Purpose: To assess the doses of activated charcoal currently used in the management of acute amitriptyline-induced drug poisoning and explore the possibility of using lower doses. Methods: Albino male Wistar rats, weighing 200 ± 20 g, were used for the study. The animals were divided into four groups of eight animals ...

  2. Hormones of thyroid gland in sera of rats treated with different dose of concentrated potassium iodine solutions

    Directory of Open Access Journals (Sweden)

    Marković Ljiljana

    2010-01-01

    Full Text Available Introduction Potassium iodine (KI is used as a drug therapy for treating numerous diseases such as small-vessel vasculitis, erythema nodosum, vasculitis nodularis, Sweet's syndrome, tuberculosis and granulomatosis, and for iodized salt. At the same time, KI can be harmful. Iodine intake may increase the frequency of thyroiditis in humans, and may induce the occurrence of experimental thyroiditis (ET in animals. Investigations on an experimental model for the examination of thyroiditis in Wistar rats have clearly showed morphological changes in the rat thyroid evoked by KI administration. Objective The purpose of this study was to compare the effects of low and high doses of KI on the thyroid gland of Wistar rats and determine the effect on hormone status (T4, T3 and TSH in this rat strain. Methods Two groups of rats from the Wistar strain were treated with a low iodine dose (225 μg/g BW and with a high iodine dose (675 μg/g BW of KI solutions. Untreated nonimmunized animals served as controls. The solution was administrated daily intraperitoneally during the period of 26 consecutive days. Results Monitoring hormone status (TSH, T3 and T4 and morphological changes it was found that therapeutic doses of KI applied in treatment induced the occurrence of experimental thyroiditis (chronic destructive Hashimoto's thyroiditis in humans and cell necrosis in animals not carrying a genetic susceptibility. Significant inflammatory changes were observed in rats treated with a high iodine dose. Conclusion The early iodine induced cell necrosis and inflammation in the nonimmunized animals without genetic susceptibility is a new experimental model of thyroiditis. .

  3. State-of-the-art of small animal imaging with high-resolution SPECT

    International Nuclear Information System (INIS)

    Nikolaus, S.; Wirrwar, A.; Antke, C.; Kley, K.; Mueller, H.W.

    2005-01-01

    During the recent years, in vivo imaging of small animals using SPECT has become of growing relevance. Along with the development of dedicated high-resolution small animal SPECT cameras, an increasing number of conventional clinical scanners has been equipped with single or multipinhole collimators. This paper reviews the small animal tomographs, which are operating at present and compares their performance characteristics. Furthermore, we describe the in vivo imaging studies, which have been performed so far with the individual scanners and survey current approaches to optimize molecular imaging with small animal SPECT. (orig.)

  4. Neuropharmacologic responses of animals to extreme effects: exposure to radiation

    International Nuclear Information System (INIS)

    Mikhajlichenko, P.P.; Tikhonchuk, V.S.; Ushakov, I.B.

    1990-01-01

    The functional state of neurochemical structures of male mice was investigated after their gamma-irradiation with 137 Cs (1.9 Gy/min) at a dose of 100 Gy. The animals were treated with the following drugs that produce selective effects on specific receptors: galanthamine, amizyl, arpenal, phenamine, phentolamine and obsidan, haloperidol, apomorphine, phenazepam, phenibut and strychnin. The results point to the development of heterologous desensibilization of receptors at early post-irradiation periods. The high effectiveness of agonists and antagonists of CNS transmitters in the nonirradiated animals and their low effectiveness in the irradiated animals and their low effectiveness in the irradiated animals may be considered as an indicator of post-radiation injury of specific receptors. These neuropharmacological interactions may obviously be modified in response to the combined effects of space flight factors

  5. High-dose radioiodine therapy of Graves disease

    International Nuclear Information System (INIS)

    Solodky, V.; Fomin, D.; Pestritskaya, E.

    2015-01-01

    Full text of publication follows. Objectives: to estimate the effectiveness and safety of the disease treatment under different modes of applying RIT. Materials and methods: 67 patients with the thyrotoxicosis condition associated with Graves disease were researched. The patients were divided into 2 groups: a control group with 25 people (18 women and 7 men), who underwent a low-dose therapy of 150-500 MBq; and a main group of 42 people (32 women and 10 men), who underwent a high-dose therapy of 550 and 800 MBq. The volume of thyroid prior to the treatment made up 23.8 ± 20 ml in the main group and 30.2 ± 23 ml in the control one. The average age in the high-dose group was 44.6 ±23 years old and in the low-dose -47.2 ± 24 years old. In terms of the hormone level before the RIT, 52% of the main group patients experienced euthyroidism, while 48% - thyrotoxicosis. The corresponding indices in the control group were 42% and 58% respectively. The cessation of the thyreostatic therapy came on 5. to 21. day prior to the treatment, with the average of 14 ±7 days in both groups. The diagnosis of the disease was based on ultrasonography, planar scintigraphy, the hormone level and antibody titer. The performance was assessed through the attainment of hypo-thyrosis and the transition to a substitutive hormonal therapy with L-thyroxine in 6 months or more. The attainment of euthyroidism was seen as a partial effect due to a possibility of relapse. Results: in 6 months a positive result in the form of hypo-thyrosis was achieved for 39 patients in the main group, which accounted for 93%, and 3 patients (7%) experienced euthyroidism. No symptomatic thyrotoxicosis relapses were revealed. In the control group, hypo-thyrosis was achieved by 18 patients, which accounted for 72%; euthyroidism came up to 12%; 4 patients needed a refresher course of RIT, which made up 16% of the group. 93% of the main group patients tolerated the treatment favourably. 3 patients complained of the

  6. Establishment of a dosimetric system for high doses using glasses

    International Nuclear Information System (INIS)

    Correa Quezada, Valeria de la Asuncion

    1997-01-01

    A routine dosimetric system was developed using commercial glass samples. The dosimetric characteristics of national and imported samples were studied: batch uniformity, response repeatability, reutilization, absorbed dose response, detection range, response stability as a function of absorbed dose, storage temperature and thermal treatments pre- and post-irradiation, using the optical absorption technique. As an application, the dosimetric system was tested in a flower irradiation process at IPEN. All the obtained results show the usefulness of the proposed system for high dose dosimetry. (author)

  7. Implementation of high-dose chemical dosimetry for industrial facilities

    International Nuclear Information System (INIS)

    Conceicao, Cirilo Cezar Sant'Anna da

    2006-01-01

    The purpose of this work is the implementation of methodology for high dose measurements using chemical dosimeters in liquid phase, traceable to the international metrology system, and make available in the country, the standard of high-dose to industrial irradiation facilities and research irradiators, trough the quality program with comparative measurements and direct use of the standard dosimeters in routine. The use of these low cost dosimetry systems in industrial irradiation facilities, assists to the certification requirements and it can reduce the costs with dosimetry for approximately 20% of the total dosimetry costs, using these systems in routine measurements and validation process, largely substituting the imported PMMA dosimeters, among others. (author)

  8. Applichation of the sulphate ceric dosimetric in the high doses range

    International Nuclear Information System (INIS)

    Prieto Miranda, F.

    1991-01-01

    The ceric-cerous dosimetric system is one of the system more employed in the high dose dosimetry. The spectrophotometric procedure to measure the ceric-concentration is an usual analityc method to determine the absorbed dose. On the other hand, due at increase employ of the irradiation process control. In this paper is realized the ceric-cerous dosimetric calibration in the dose range of 0,6 - 5 kGy and the application in the irradiation process control to differents absorbed dose values

  9. Deposition, translocation and effects of transuranic particles inhaled by experimental animals

    International Nuclear Information System (INIS)

    Craig, D.K.; Ballou, J.E.; Dagle, G.E.; Mahlum, D.D.; Park, J.F.; Sanders, C.L.; Sikov, M.R.; Stuart, B.O.

    1977-01-01

    Inhalation exposure constitutes the most likely route of entrance for transuranics into the body. Cancer is the most likely consequence of exposure, but several thousand workers have been exposed during the last 30 yrs without, so far, evidence of exposure-related effects. Several soluble and insoluble transuranic compounds have been studied in rodents and dogs, either alone or combined with exposure to other materials (e.g., PuO/sub 2/--UO/sub 2/ fuel and Na). These studies have provided a wide variety of spatial and temporal dose distribution patterns in the lung. The distribution and total initial deposition in the respiratory tract is a function of the physical characteristics of the inhaled aerosols (size distribution, shape, hygroscopicity) and of the morphology and physiology of the animal. Translocation rates, organ and tissue distribution and excretion in urine and feces, are a function of the physicochemical characteristics of the deposited material (solubility, specific activity, chemical compound, etc.). Differences in rate of translocation of the solubilized material, primarily to the liver and bone, determines the radiation dose to the various tissues involved. Insoluble particles of plutonium dioxide are transferred to the thoracic lymph nodes, which may be functionally destroyed as a consequence. Radiation pneumonitis and pulmonary fibrosis are the main causes of death in animals with cumulative radiation doses to the lung of a few thousand rads. The most significant long-term effect of inhaled transuranic compounds in animals is the development of lung and bone tumors. The main type of lung tumor in both dog and rat is the bronchioloalveolar carcinoma (adenocarcinoma). However, tumor type is a function of radiation dose and dose-distribution at high doses. Bone ranks next to lung as the tissue developing the most tumors following inhalation of transuranics

  10. Deposition, translocation, and effects of transuranic particles inhaled by experimental animals

    International Nuclear Information System (INIS)

    Craig, D.K.; Ballou, J.E.; Dagle, G.E.; Mahlum, D.D.; Park, J.F.; Sanders, C.L.; Sikov, M.R.; Stuart, B.O.

    1977-01-01

    Inhalation exposure constitutes the most likely route of entrance for transuranics into the body. Cancer is the most likely consequence of exposure, but several thousand workers have been exposed during the last 30 yrs without, so far, evidence of exposure-related effects. Several soluble and insoluble transuranic compounds have been studied in rodents and dogs, either alone or combined with exposure to other materials (e.g., PuO 2 --UO 2 fuel and Na). These studies have provided a wide variety of spatial and temporal dose distribution patterns in the lung. The distribution and total initial deposition in the respiratory tract is a function of the physical characteristics of the inhaled aerosols (size distribution, shape, hygroscopicity) and of the morphology and physiology of the animal. Translocation rates, organ and tissue distribution and excretion in urine and feces, are a function of the physicochemical characteristics of the deposited material (solubility, specific activity, chemical compound, etc.). Differences in rate of translocation of the solubilized material, primarily to the liver and bone, determines the radiation dose to the various tissues involved. Insoluble particles of plutonium dioxide are transferred to the thoracic lymph nodes, which may be functionally destroyed as a consequence. Radiation pneumonitis and pulmonary fibrosis are the main causes of death in animals with cumulative radiation doses to the lung of a few thousand rads. The most significant long-term effect of inhaled transuranic compounds in animals is the development of lung and bone tumors. The main type of lung tumor in both dog and rat is the bronchioloalveolar carcinoma (adenocarcinoma). However, tumor type is a function of radiation dose and dose-distribution at high doses. Bone ranks next to lung as the tissue developing the most tumors following inhalation of transuranics

  11. Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

    International Nuclear Information System (INIS)

    Fiandra, Christian; Ragona, Riccardo; Ricardi, Umberto; Anglesio, Silvia; Giglioli, Francesca Romana

    2008-01-01

    The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K sat ) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

  12. High-speed radiation dose calculations for severe accidents using INDOS

    International Nuclear Information System (INIS)

    Davidson, G.R.; Godin-Jacqmin, L.J.; Raines, J.C.

    1992-01-01

    The computer code INDOS (in-plant dose) has been developed for the high-speed calculation of in-plant radiation dose rates and doses during and/or due to a severe accident at a nuclear power plant. This paper describes the current capabilities of the code and presents the results of calculations for several severe-accident scenarios. The INDOS code can be run either as a module of MAAP, a code widely used in the nuclear industry for simulating the response of a light water reactor system during severe accidents, or as a stand-alone code using output from an alternative companion code. INDOS calculates gamma dose rates and doses in major plant compartments caused by airborne and deposited fission products released during an accident. The fission product concentrations are determined by the companion code

  13. Biological transport of curium-243 in dairy animals

    International Nuclear Information System (INIS)

    Sutton, W.W.; Patzer, R.G.; Hahn, P.B.; Potter, G.D.

    1979-04-01

    Lactating cows and goats were used to examine the biological transport of curium-243 in dairy animals. After either single oral or intravenous nuclide doses were administered, samples of milk, urine, blood, and feces were taken over a 144-hr priod, and the curium concentrations were determined by gamma counting. Gastrointestinal uptake of curium was estimated to be 0.02 and 0.006% of the oral dose for cows and goats, respectively. The cumulative percentage of oral dose transported to milk and urine was 4.6 x 10 -4 and 1.9 x 10 -3 , respectively, for a cow and 2.7 x 10 -4 and 1.6 x 10 -4 , respectively, for goats. Plasma concentrations of curium decreased rapidly following all intravenous injections. The average percentage of injected curium transferred to milk, urine, and feces was 2, 8, and 1, respectively, for a cow and 2, 5, and 5, respectively, for goats. All animals were sacrificed one week after dosing. Bovine bone retained the greatest fraction of the administered dose and the next highest was the liver. However, in all three intravenously dosed goats the liver contained the greatest amount of curium. Nuclide deposition in bone and liver was essentially equal for two of the three orally dosed goats while the skeleton contained the most curium in the other animal. Comparisons are presented between curium-243 and americium-241 transport in dairy cows

  14. A comparison of high-dose and low-dose tranexamic acid antifibrinolytic protocols for primary coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Stephen M McHugh

    2016-01-01

    Full Text Available Background and Aims: Tranexamic acid (TA is used for prophylactic antifibrinolysis in coronary artery bypass surgeries to reduce bleeding. We evaluated the efficacy of two different doses of TA for prophylactic antifibrinolysis in patients undergoing primary coronary artery bypass grafting (CABG surgery in this retrospective cohort study at a tertiary care referral centre. Methods: One-hundred eighty-four patients who underwent primary CABG with cardiopulmonary bypass (CPB via sternotomy between January 2009 and June 2011 were evaluated. Pre-operative patient characteristics, intraoperative data, post-operative bleeding, transfusions, organ dysfunction and 30-day mortality were compared between high-dose TA (30 mg/kg loading dose followed by infusion of 15 mg/kg/h until the end of surgery along with 2 mg/kg priming dose in the bypass circuit and low-dose TA (15 mg/kg loading dose followed by infusion of 6 mg/kg/h until the end of surgery along with 1 mg/kg priming dose in the bypass circuit groups. Univariate comparative analysis of all categorical and continuous variables was performed between the two groups by appropriate statistical tests. Linear and logistic regression analyses were performed to control for the effect of confounding on the outcome variables. Results: Chest tube output, perioperative transfusion of blood products and incidence of re-exploration for bleeding did not differ significantly (P> 0.05 between groups. Post-operative complications and 30-day mortality were comparable between the groups. The presence of cardiogenic shock and increased pre-operative creatinine were found to be associated with increased chest tube output on the post-operative day 2 by multivariable linear regression model. Conclusions: Low-dose TA protocol is as effective as high-dose protocol for antifibrinolysis in patients undergoing primary CABG with CPB.

  15. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  16. Effect of High-Dose vs Standard-Dose Wintertime Vitamin D Supplementation on Viral Upper Respiratory Tract Infections in Young Healthy Children.

    Science.gov (United States)

    Aglipay, Mary; Birken, Catherine S; Parkin, Patricia C; Loeb, Mark B; Thorpe, Kevin; Chen, Yang; Laupacis, Andreas; Mamdani, Muhammad; Macarthur, Colin; Hoch, Jeffrey S; Mazzulli, Tony; Maguire, Jonathon L

    2017-07-18

    Epidemiological studies support a link between low 25-hydroxyvitamin D levels and a higher risk of viral upper respiratory tract infections. However, whether winter supplementation of vitamin D reduces the risk among children is unknown. To determine whether high-dose vs standard-dose vitamin D supplementation reduces the incidence of wintertime upper respiratory tract infections in young children. A randomized clinical trial was conducted during the winter months between September 13, 2011, and June 30, 2015, among children aged 1 through 5 years enrolled in TARGet Kids!, a multisite primary care practice-based research network in Toronto, Ontario, Canada. Three hundred forty-nine participants were randomized to receive 2000 IU/d of vitamin D oral supplementation (high-dose group) vs 354 participants who were randomized to receive 400 IU/d (standard-dose group) for a minimum of 4 months between September and May. The primary outcome was the number of laboratory-confirmed viral upper respiratory tract infections based on parent-collected nasal swabs over the winter months. Secondary outcomes included the number of influenza infections, noninfluenza infections, parent-reported upper respiratory tract illnesses, time to first upper respiratory tract infection, and serum 25-hydroxyvitamin D levels at study termination. Among 703 participants who were randomized (mean age, 2.7 years, 57.7% boys), 699 (99.4%) completed the trial. The mean number of laboratory-confirmed upper respiratory tract infections per child was 1.05 (95% CI, 0.91-1.19) for the high-dose group and 1.03 (95% CI, 0.90-1.16) for the standard-dose group, for a between-group difference of 0.02 (95% CI, -0.17 to 0.21) per child. There was no statistically significant difference in number of laboratory-confirmed infections between groups (incidence rate ratio [RR], 0.97; 95% CI, 0.80-1.16). There was also no significant difference in the median time to the first laboratory-confirmed infection: 3.95 months

  17. Radiation-induced rectal complications are not influenced by age: a dose fractionation study in the rat.

    Science.gov (United States)

    van den Aardweg, Gerard J M J; Olofsen-van Acht, Manouk J J; van Hooije, Christel M C; Levendag, Peter C

    2003-05-01

    Radiation-induced complications of the rectum are an important dose-limiting factor in radiotherapy of pelvic malignancies. In general, animal studies demonstrated no differences in acute and late normal tissue toxicity with age, but little is known about rectal complications in relation to age. For this purpose, an extensive histological and dose fractionation study was carried out on the rectum of young (12 weeks) and older (77-80 weeks) rats. In this paper, the results of dose fractionation are presented in relation to age at the time of irradiation. Young and older animals were irradiated with single and fractionated doses. After irradiation, rectal complications could lead to occlusion and stenosis, eventually resulting in the clinical symptoms of a megacolon and a possible fistula. For each dose group, cumulative survival rates were obtained with Kaplan-Meier analysis, from which dose-effect curves and the associated LD(50) values for a megacolon/fistula were calculated. The majority of responders died between 8 and 24 weeks after irradiation, irrespective of age. For both age groups, only the fractionation data showed a reduction in the mean latency with increasing dose. In the older age group, 39% of the responders developed a fistula compared to 26% for the younger animals. The LD(50) values increased from around 30 Gy after single doses to nearly 65 Gy after 10 fractions. The increases in LD(50) values with the number of fractions were independent of the age of the rats. For each of the dose fractionation schedules, log-rank testing indicated no significant differences in cumulative survival rates between younger and older animals (P > 0.10). The high alpha/beta ratios obtained for both the young and older animals strongly suggested that the late rectal complications were a consequence of early epithelial injury. Associated histological findings indicated that blood vessel damage, which was already evident at a high incidence at 4 weeks after irradiation

  18. High dose rate brachytherapy for oral cancer.

    Science.gov (United States)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  19. Incidence of high-level evernimicin resistance in Enterococcus faecium among food animals and humans

    DEFF Research Database (Denmark)

    Aarestrup, Frank Møller; McNicholas, P. M.

    2002-01-01

    Six high-level evernimicin-resistant Enterococcus faecium isolates were identified among 304 avilarnycin-resistant E. faecium isolates from animals and 404 stool samples from humans with diarrhea. All four animal isolates, and one of the human isolates, were able to transfer resistance...... to a susceptible E. faecium strain. The resulting transconjugants all tested positive for the presence of emtA, a gene encoding a methyltransferase previously linked with high-level evernimicin resistance. The four transconjugants derived from animal isolates all carried the same plasmid, while a differently sized...... plasmid was found in the isolate from humans. This study demonstrated a low incidence of high-level evernimicin resistance mediated by the emtA gene in different E. faecium isolates of animal and human origin....

  20. The effects of a high-animal- and a high-vegetable-protein diet on mineral balance and bowel function of young men

    NARCIS (Netherlands)

    Dokkum, W. van; Wesstra, A.; Luyken, R.; Hermus, R.J.J.

    1986-01-01

    Twelve young men were given for periods of 20 d, each of three mixed diets, namely a low-protein (LP) diet (9% total energy as protein, 67% of animal origin), a high-animal-protein (HA) diet (16% total energy as protein, 67% of animal origin) and a high-vegetable-protein (HV) diet (16% total energy

  1. Low dose versus high dose anti-snake venom therapy in the treatment of haematotoxic snake bite in South India.

    Science.gov (United States)

    Joseph, Imanto M; Kuriakose, Cijoy K; Dev, Anand Vimal; Philip, George A

    2017-10-01

    Most of the studies on the appropriate dose of anti-snake venom (ASV) are from tertiary hospitals and the guidelines are unclear. Our observational study compared the outcomes of two prevalent treatment regimes for haematotoxic snake bite in a secondary care hospital in South India. The time to normalisation of whole blood clotting time, mortality and complications were not different between the groups. The average dose of ASV required in the low and high dose groups were 106 mL and 246 mL, respectively. Consequently, patients who received low dose ASV incurred approximately 50% less expense. Urticarial rashes were also significantly fewer in the low dose group.

  2. Histology and Gadolinium Distribution in the Rodent Brain After the Administration of Cumulative High Doses of Linear and Macrocyclic Gadolinium-Based Contrast Agents.

    Science.gov (United States)

    Lohrke, Jessica; Frisk, Anna-Lena; Frenzel, Thomas; Schöckel, Laura; Rosenbruch, Martin; Jost, Gregor; Lenhard, Diana Constanze; Sieber, Martin A; Nischwitz, Volker; Küppers, Astrid; Pietsch, Hubertus

    2017-06-01

    Retrospective studies in patients with primary brain tumors or other central nervous system pathologies as well as postmortem studies have suggested that gadolinium (Gd) deposition occurs in the dentate nucleus (DN) and globus pallidus (GP) after multiple administrations of primarily linear Gd-based contrast agents (GBCAs). However, this deposition has not been associated with any adverse effects or histopathological alterations. The aim of this preclinical study was to systematically examine differences between linear and macrocyclic GBCAs in their potential to induce changes in brain and skin histology including Gd distribution in high spatial resolution. Fifty male Wistar-Han rats were randomly allocated into control (saline, n = 10 rats) and 4 GBCA groups (linear GBCAs: gadodiamide and gadopentetate dimeglumine, macrocyclic GBCAs: gadobutrol and gadoteridol; n = 10 rats per group). The animals received 20 daily intravenous injections at a dose of 2.5 mmol Gd/kg body weight. Eight weeks after the last GBCA administration, the animals were killed, and the brain and skin samples were histopathologically assessed (hematoxylin and eosin; cresyl violet [Nissl]) and by immunohistochemistry. The Gd concentration in the skin, bone, brain, and skeletal muscle samples were analyzed using inductively coupled plasma mass spectroscopy (ICP-MS, n = 4). The spatial Gd distribution in the brain and skin samples was analyzed in cryosections using laser ablation coupled with ICP-MS (LA-ICP-MS, n = 3). For the ultra-high resolution of Gd distribution, brain sections of rats injected with gadodiamide or saline (n = 1) were assessed by scanning electron microscopy coupled to energy dispersive x-ray spectroscopy and transmission electron microscopy, respectively. No histological changes were observed in the brain. In contrast, 4 of 10 animals in the gadodiamide group but none of the animals in other groups showed macroscopic and histological nephrogenic systemic fibrosis-like skin

  3. Monte Carlo dosimetry of iodine contrast objects in a small animal microCT

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Villafuerte, M., E-mail: mercedes@fisica.unam.mx [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico); Martinez-Davalos, A. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico)

    2011-08-21

    Small animal microcomputed tomography (microCT) studies with iodine-based contrast media are commonly used in preclinical research. While the use of contrast media improves the quality of the images, it can also result in an increase in the absorbed dose to organs with high concentration of the contrast agent, which might cause radiation damage to the animal. In this work we present the results of a Monte Carlo investigation of a microCT dosimetry study using mouse-sized cylindrical water phantoms with iodine contrast insets for different X-ray spectra (Mo and W targets, 30-80 kVp), iodine concentrations (0, 5, 10 and 15 mg mL{sup -1}) and contrast object sizes (3 and 10 mm diameter). Our results indicate an absorbed dose increase in the contrast-inset regions with respect to the absorbed dose distribution within a reference uniform water phantom. The calculated spatial absorbed dose distributions show large gradients due to beam hardening effects, and large absorbed dose enhancement as the mean energy of the beam and iodine concentration increase. We have found that absorbed doses in iodine contrast objects can increase by a factor of up to 12 for a realistic 80 kVp X-ray spectra and an iodine concentration of 15 mg mL{sup -1}.

  4. Influence of dose and its distribution in time on dose-response relationships for low-LET radiation

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This book examines the influence of dose rate and magnitude on the genetic and carcinogenic effects of radiation exposure in animals and man. It systematically examines a broad range of biological effects in simple systems, plants, laboratory animals, and man with special attention given to the effects of prenatal irradiation, changes in life span, and tumorigenesis. An enormous volume of data is provided about human tumorigenesis and the data and shortcomings are summarized. There is an extended general discussion of the consideration in quantitative dose and dose rate relationships and of the limitations of the data and analyses which have led to a linear interpolation of risk at low doses and dose rates. An argument is made for dose rate dependence in tumorigenesis as being consistent with all other radiation effects and for the applicability of Dose Rate Effectiveness Factors (DREF) in providing a more realistic assessment of the risk of radiation carcinogenesis. The report is documented with 24 pages of references. There are numerous graphs and tables, all clear and to the point. This book is a superb review and summary of the data on radiation risks

  5. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  6. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko; Furukawa, Souhei; Kakimoto, Naoya

    2003-01-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  7. Transient alterations in neurotransmitter activity in the caudate nucleus of rat brain after a high dose of ionizing radiation

    International Nuclear Information System (INIS)

    Hunt, W.A.; Dalton, T.K.; Darden, J.H.

    1979-01-01

    A single 10,000-rad dose of high-energy electrons induced an increase in dopaminergic and cholinergic activity in the caudate nucleus of the rat brain as assessed by K + -stimulated dopamine release in vitro and high-affinity choline uptake. These alterations occur during early transient incapacitation (ETI) and dissipate as the animal recovers behaviorally, in about 30 min after irradiation. Although the responses observed resemble those that result from blockade of dopamine receptors, no radiation-induced changes were found in dopamine-sensitive adenylate cyclase activity and [ 3 H]haloperidol binding, two indices of dopaminergic receptor function. The data suggest that changes in dopaminergic and cholinergic activity are associated with the development of ETI and may play a role in the behavioral decrement observed under this condition

  8. Radiation shielding and dose rate distribution for the building of the high dose rate accelerator

    International Nuclear Information System (INIS)

    Matsuda, Koji; Takagaki, Torao; Nakase, Yoshiaki; Nakai, Yohta.

    1984-03-01

    A high dose rate electron accelerator was established at Osaka Laboratory for Radiation Chemistry, Takasaki Establishment, JAERI in the fiscal year of 1975. This report shows the fundamental concept for the radiation shielding of the accelerator building and the results of their calculations which were evaluated through the model experiments. After the construction of the building, the leak radiation was measured in order to evaluate the calculating method of radiation shielding. Dose rate distribution of X-rays was also measured in the whole area of the irradiation room as a data base. (author)

  9. Can we avoid high levels of dose escalation for high-risk prostate cancer in the setting of androgen deprivation?

    Science.gov (United States)

    Shakespeare, Thomas P; Wilcox, Shea W; Aherne, Noel J

    2016-01-01

    Both dose-escalated external beam radiotherapy (DE-EBRT) and androgen deprivation therapy (ADT) improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3-6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered.

  10. Interaction of 2-Gy Equivalent Dose and Margin Status in Perioperative High-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Martinez-Monge, Rafael; Cambeiro, Mauricio; Moreno, Marta; Gaztanaga, Miren; San Julian, Mikel; Alcalde, Juan; Jurado, Matias

    2011-01-01

    Purpose: To determine patient, tumor, and treatment factors predictive of local control (LC) in a series of patients treated with either perioperative high-dose-rate brachytherapy (PHDRB) alone (Group 1) or with PHDRB combined with external-beam radiotherapy (EBRT) (Group 2). Patient and Methods: Patients (n = 312) enrolled in several PHDRB prospective Phase I-II studies conducted at the Clinica Universidad de Navarra were analyzed. Treatment with PHDRB alone, mainly because of prior irradiation, was used in 126 patients to total doses of 32 Gy/8 b.i.d. or 40 Gy/10 b.i.d. treatments after R0 or R1 resections. Treatment with PHDRB plus EBRT was used in 186 patients to total doses of 16 Gy/4 b.i.d. or 24 Gy/6 b.i.d. treatments after R0 or R1 resections along with 45 Gy of EBRT with or without concomitant chemotherapy. Results: No dose-margin interaction was observed in Group 1 patients. In Group 2 patients there was a significant interaction between margin status and 2-Gy equivalent (Eq2Gy) dose (p = 0.002): (1) patients with negative margins had 9-year LC of 95.7% at Eq2Gy = 62.9Gy; (2) patients with close margins of >1 mm had 9-year LC of 92.4% at Eq2Gy = 72.2Gy, and (3) patients with positive/close <1-mm margins had 9-year LC of 68.0% at Eq2Gy = 72.2Gy. Conclusions: Two-gray equivalent doses ≥70 Gy may compensate the effect of close margins ≥1 mm but do not counterbalance the detrimental effect of unfavorable (positive/close <1 mm) resection margins. No dose-margin interaction is observed in patients treated at lower Eq2Gy doses ≤50 Gy with PHDRB alone.

  11. Efficacy and Tolerability of High-Dose Escitalopram in Posttraumatic Stress Disorder.

    Science.gov (United States)

    Qi, Wei; Gevonden, Martin; Shalev, Arieh

    2017-02-01

    Open-label trials suggest that escitalopram (up to 20 mg/d) is an effective treatment for some, but not all posttraumatic stress disorder (PTSD) patients. Higher doses of escitalopram effectively reduced major depression symptoms in patients who had not responded to regular doses. The current study examines the efficacy, tolerability, and adherence to high-dose escitalopram in PTSD. Forty-five PTSD patients received 12 weeks of gradually increasing doses of escitalopram reaching 40 mg daily at 4 weeks. Among those, 12 participants received regular doses of antidepressants at study onset including escitalopram (n = 7). The Clinician-Administered PTSD Scale (CAPS) evaluated PTSD symptoms severity before treatment, at 3 months (upon treatment termination), and at 6 months (maintenance effect). A 20% reduction in CAPS scores was deemed clinically significant. Adverse events and medication adherence were monitored at each clinical session. Linear mixed-models analysis showed a significant reduction of mean CAPS scores (11.5 ± 18.1 points) at 3 months and maintenance of gains by 6 months (F2,34.56 = 8.15, P = 0.001). Eleven participants (34.3%) showed clinically significant improvement at 3 months. Only 9 participants (20%) left the study. There were no serious adverse events and few mild ones with only 2 adverse events (diarrhea, 11.1%; drowsiness, 11.1%) reported by more than 10% of participants. High doses of escitalopram are tolerable and well adhered to in PTSD. Their beneficial effect at a group level is due to a particularly good response in a subset of patients.Variability in prior pharmacological treatment precludes a definite attribution of the results to high doses of escitalopram.

  12. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  13. Neutron dose to patients treated with high-energy medical accelerators

    International Nuclear Information System (INIS)

    McGinley, P.H.

    2001-01-01

    The neutron dose equivalent received by patients treated with high energy x-ray beams was measured in this research. A total of 13 different medical accelerators were evaluated in terms of the neutron dose equivalent in the patient plane and at the beam center. The neutron dose equivalent at the beam center was found to ranged from 0.02 to 9.4 mSv per Sv of x-ray dose and values from 0.029 to 2.58 mSv per Sv of x-ray were measured in the patient plane. It was concluded that the neutron levels meet the International Electrotechnical Commission standard for the patient plane. It was also concluded that when intensity modulated radiation treatment is conducted the neutron dose equivalent received by the patient will increase by a factor of 2 to 10. (author)

  14. Study of a new glass matrix by thermoluminescent technique for high-dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Pamela Z.; Carvalho, Gabriel S. Marchiori de; Cunha, Diego M. da; Dantas, Noelio O.; Silva, Anielle C.A.; Neves, Lucio P.; Perini, Ana P., E-mail: anapaula.perini@ufu.br [Universidade Federal de Uberlandia (UFU), MG (Brazil). Instituto de Fisica; Linda, V.E. Caldas [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Carrera, Betzabel N.S.; Watanabe, Shigueo [Universidade de Sao Paulo (IF/USP), Sao Paulo, SP (Brazil). Instituto de Fisica

    2016-07-01

    The thermoluminescence technique is widely used for both personal and for high-dose dosimetry. In this work, the thermoluminescence technique was utilized to study a new glass matrix, with nominal composition of 20Li{sub 2}CO{sub 3}.10Al{sub 2}O{sub 3}.30BaO.40B{sub 2}O{sub 3} (mol%), irradiated with different doses in a {sup 60}Co source. The glow curves and the dose-response curve were obtained for radiation doses of 10, 50, 100, 200 e 700 Gy. The results showed that this new glass matrix has potential use in high-dose dosimetry. (author)

  15. Erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA

    International Nuclear Information System (INIS)

    Speight, E.L.; Farr, P.M.

    1994-01-01

    In PUVA treatment of psoriasis, clinical observation suggests that uninvolved skin is more susceptible to PUVA erythema than lesions of psoriasis. If this is the case, then the efficacy of PUVA treatment might be increased by using localized high-dose UVA restricted to lesional skin. We have therefore studied the erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA and, for comparison, the erythemal response to UVB. This study demonstrates that psoriasis may clear rapidly, without burning, using high-dose UVA. Availability of a suitable irradiation apparatus would allow rapid and effective PUVA treatment to be used for localized, resistant disease. (author)

  16. A review of treatment planning for precision image-guided photon beam pre-clinical animal radiation studies

    International Nuclear Information System (INIS)

    Verhaegen, Frank; Hoof, Stefan van; Granton, Patrick V.; Trani, Daniela

    2014-01-01

    Recently, precision irradiators integrated with a high-resolution CT imaging device became available for pre-clinical studies. These research platforms offer significant advantages over older generations of animal irradiators in terms of precision and accuracy of image-guided radiation targeting. These platforms are expected to play a significant role in defining experiments that will allow translation of research findings to the human clinical setting. In the field of radiotherapy, but also others such as neurology, the platforms create unique opportunities to explore e.g. the synergy between radiation and drugs or other agents. To fully exploit the advantages of this new technology, accurate methods are needed to plan the irradiation and to calculate the three-dimensional radiation dose distribution in the specimen. To this end, dedicated treatment planning systems are needed. In this review we will discuss specific issues for precision irradiation of small animals, we will describe the workflow of animal treatment planning, and we will examine several dose calculation algorithms (factorization, superposition-convolution, Monte Carlo simulation) used for animal irradiation with kilovolt photon beams. Issues such as dose reporting methods, photon scatter, tissue segmentation and motion will also be discussed briefly.

  17. High dose-per-pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical use.

    Science.gov (United States)

    Jaccard, Maud; Durán, Maria Teresa; Petersson, Kristoffer; Germond, Jean-François; Liger, Philippe; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François; Bailat, Claude

    2018-02-01

    The Oriatron eRT6 is an experimental high dose-per-pulse linear accelerator (linac) which was designed to deliver an electron beam with variable dose-rates, ranging from a few Gy/min up to hundreds of Gy/s. It was built to study the radiobiological effects of high dose-per-pulse/dose-rate electron beam irradiation, in the context of preclinical and cognitive studies. In this work, we report on the commissioning and beam monitoring of the Oriatron eRT6 prototype linac. The beam was characterized in different steps. The output stability was studied by performing repeated measurements over a period of 20 months. The relative output variations caused by changing beam parameters, such as the temporal electron pulse width, the pulse repetition frequency and the pulse amplitude were also analyzed. Finally, depth dose curves and field sizes were measured for two different beam settings, resulting in one beam with a conventional radiotherapy dose-rate and one with a much higher dose-rate. Measurements were performed with Gafchromic EBT3 films and with a PTW Advanced Markus ionization chamber. In addition, we developed a beam current monitoring system based on the signals from an induction torus positioned at the beam exit of the waveguide and from a graphite beam collimator. The stability of the output over repeated measurements was found to be good, with a standard deviation smaller than 1%. However, non-negligible day-to-day variations of the beam output were observed. Those output variations showed different trends depending on the dose-rate. The analysis of the relative output variation as a function of various beam parameters showed that in a given configuration, the dose-rate could be reliably varied over three orders of magnitude. Interdependence effects on the output variation between the parameters were also observed. The beam energy and field size were found to be slightly dose-rate-dependent and suitable mainly for small animal irradiation. The beam monitoring

  18. Treatment of carcinoma of uterine cervix with high-dose-rate intracavitary irradiation using Ralstron

    International Nuclear Information System (INIS)

    Suh, C.O.; Kim, G.E.; Loh, J.J.K.

    1988-01-01

    From May 1979 through December 1981, a total of 530 patients with carcinoma of the uterine cervix were treated with radiation therapy with curative intent. Of the 530 patients, 365 were treated with a high-dose-rate remote-controlled afterloading system (RALS) using a cobalt source, and 165 patients received a low dose rate using a radium source. External pelvic irradiation with a total of 40-50 Gy to the whole pelvis followed by intracavitary radiation (ICR) with a total dose of 30-39 Gy in ten to 13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rate with high-dose-rate ICR by stage was as follows: stage I:82.7% (N = 19) stage II:69.6% (N = 184), and stage III:52.2% (N = 156). The above results were comparable with those with conventional low-dose-rate ICR treatment, and late complications were far less. The application of high-dose-rate ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually none as compared with that of low-dose-rate ICR. Within a given period of time, more patients can be treated with high-dose-rate ICR because of the short treatment time. The authors therefore conclude that high-dose-rate ICR is suitable for a cancer center where a large number of patients are to be treated

  19. Ion exchange resins as high-dose radiation dosimeters

    International Nuclear Information System (INIS)

    Alian, A.; Dessouki, A.; El-Assay, N.B.

    1984-01-01

    This paper reports on the possibility of using various types of ion exchange resins as high-dose radiation dosimeters, by analysis of the decrease in exchange capacity with absorbed dose. The resins studied are Sojuzchim-export-Moscow Cation Exchanger KU-2 and Anion Exchanger AV-17 and Merck Cation Exchanger I, and Merck Anion Exchangers II and III. Over the dose range 1 to 100 kGy, the systems show linearity between log absorbed dose and decrease in resin ion exchange capacity. The slope of this response function differs for the different resins, depending on their ionic form and degree of cross-linking. The radiation sensitivity increases in the order KU-2; Exchanger I; AV-17; Exchanger II; Exchanger III. Merck resins with moisture content of 21% showed considerably higher radiation sensitivity than those with 2 to 3% moisture content. The mechanism of radiation-induced denaturing of the ion exchanger resins involves cleavage and decomposition of functional substituents, with crosslinking playing a stabilizing role, with water and its radiolytic products serving to inhibit radical recombination and interfering with the protection cage effect of crosslinking. (author)

  20. Can we avoid high levels of dose escalation for high-risk prostate cancer in the setting of androgen deprivation?

    Directory of Open Access Journals (Sweden)

    Shakespeare TP

    2016-05-01

    Full Text Available Thomas P Shakespeare,1,2 Shea W Wilcox,1 Noel J Aherne1,2 1Department of Radiation Oncology, North Coast Cancer Institute, 2Rural Clinical School, Faculty of Medicine, University of New South Wales, Coffs Harbour, NSW, Australia Aim: Both dose-escalated external beam radiotherapy (DE-EBRT and androgen deprivation therapy (ADT improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients and methods: Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3–6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. Results: In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. Conclusion: There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered. Keywords: radiotherapy, IMRT, dose

  1. Lifetime radiation risks from low-dose rate radionuclides in beagles

    International Nuclear Information System (INIS)

    Goldman, M.; Rosenblatt, L.S.

    1985-01-01

    One of the largest, long-term (25-yr) animal studies on the effects of low-dose internal irradiation is almost completed. Some 335 beagles were given continuous exposure to graded 90 Sr [low linear energy transfer (LET)] in their diets (D-dogs) through adulthood. A second group (R-dogs) was given fractionated doses of 225 Ra (high LET) as young adults. A third group of 44 was given a single injection of 90 Sr as adults (S-dogs) to compare single to continuous dosages. All dogs were followed through their lifetimes. Only one of the 848 dogs is still alive. The animals were whole-body counted over their entire life span and were examined frequently for assessment of medical status. There were no acute radiation lethalities. Analyses of the large data base from these dogs have begun and preliminary indications are that 90 Sr, which was tested over a 1500-fold skeletal dose rate range, does not cause significant life shortening at average accumulation skeletal doses of ∼2500 rads (25 Gy) and that a curvilinear dose response curve for life shortening was seen at higher accumulation doses. The data will be discussed in terms of modern epidemiological concepts and quantifications will be related to certain parameters of human risk from acute or chronic radiation exposures

  2. High-Dose Versus Low-Dose Pitavastatin in Japanese Patients With Stable Coronary Artery Disease (REAL-CAD): A Randomized Superiority Trial.

    Science.gov (United States)

    Taguchi, Isao; Iimuro, Satoshi; Iwata, Hiroshi; Takashima, Hiroaki; Abe, Mitsuru; Amiya, Eisuke; Ogawa, Takanori; Ozaki, Yukio; Sakuma, Ichiro; Nakagawa, Yoshihisa; Hibi, Kiyoshi; Hiro, Takafumi; Fukumoto, Yoshihiro; Hokimoto, Seiji; Miyauchi, Katsumi; Yamazaki, Tsutomu; Ito, Hiroshi; Otsuji, Yutaka; Kimura, Kazuo; Takahashi, Jun; Hirayama, Atsushi; Yokoi, Hiroyoshi; Kitagawa, Kazuo; Urabe, Takao; Okada, Yasushi; Terayama, Yasuo; Toyoda, Kazunori; Nagao, Takehiko; Matsumoto, Masayasu; Ohashi, Yasuo; Kaneko, Tetsuji; Fujita, Retsu; Ohtsu, Hiroshi; Ogawa, Hisao; Daida, Hiroyuki; Shimokawa, Hiroaki; Saito, Yasushi; Kimura, Takeshi; Inoue, Teruo; Matsuzaki, Masunori; Nagai, Ryozo

    2018-05-08

    Current guidelines call for high-intensity statin therapy in patients with cardiovascular disease on the basis of several previous "more versus less statins" trials. However, no clear evidence for more versus less statins has been established in an Asian population. In this prospective, multicenter, randomized, open-label, blinded end point study, 13 054 Japanese patients with stable coronary artery disease who achieved low-density lipoprotein cholesterol (LDL-C) fashion to high-dose (pitavastatin 4 mg/d; n=6526) or low-dose (pitavastatin 1 mg/d; n=6528) statin therapy. The primary end point was a composite of cardiovascular death, nonfatal myocardial infarction, nonfatal ischemic stroke, or unstable angina requiring emergency hospitalization. The secondary composite end point was a composite of the primary end point and clinically indicated coronary revascularization excluding target-lesion revascularization at sites of prior percutaneous coronary intervention. The mean age of the study population was 68 years, and 83% were male. The mean LDL-C level before enrollment was 93 mg/dL with 91% of patients taking statins. The baseline LDL-C level after the run-in period on pitavastatin 1 mg/d was 87.7 and 88.1 mg/dL in the high-dose and low-dose groups, respectively. During the entire course of follow-up, LDL-C in the high-dose group was lower by 14.7 mg/dL than in the low-dose group ( P Japanese patients with stable coronary artery disease. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01042730. © 2018 The Authors.

  3. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  4. Tissue responses to low protracted doses of high LET radiations or photons: Early and late damage relevant to radio-protective countermeasures

    Science.gov (United States)

    Ainsworth, E. J.; Afzal, S. M. J.; Crouse, D. A.; Hanson, W. R.; Fry, R. J. M.

    Early and late murine tissue responses to single or fractionated low doses of heavy charged particles, fission-spectrum neutrons or gamma rays are considered. Damage to the hematopoietic system is emphasized, but results on acute lethality, host response to challenge with transplanted leukemia cells and life-shortening are presented. Low dose rates per fraction were used in some neutron experiments. Split-dose lethality studies (LD 50/30) with fission neutrons indicated greater accumulation of injury during a 9 fraction course (over 17 days) than was the case for γ-radiation. When total doses of 96 or 247 cGy of neutrons or γ rays were given as a single dose or in 9 fractions, a significant sparing effect on femur CFU-S depression was observed for both radiation qualities during the first 11 days, but there was not an earlier return to normal with dose fractionation. During the 9 fraction sequence, a significant sparing effect of low dose rate on CFU-S depression was observed in both neutron and γ-irradiated mice. CFU-S content at the end of the fractionation sequence did not correlate with measured LD 50/30. Sustained depression of femur and spleen CFU-S and a significant thrombocytopenia were observed when a total neutron dose of 240 cGy was given in 72 fractions over 24 weeks at low dose rates. The temporal aspects of CFU-S repopulation were different after a single versus fractionated neutron doses. The sustained reduction in the size of the CFU-S population was accompanied by an increase in the fraction in DNA synthesis. The proliferation characteristics and effects of age were different for radial CFU-S population closely associated with bone, compared with the axial population that can be readily aspirated from the femur. In aged irradiated animals, the CFU-S proliferation/redistribution response to typhoid vaccine showed both an age and radiation effect. After high single doses of neutrons or γ rays, a significant age- and radiation-related deficiency

  5. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva; Yoriyaz, Hélio; Tedgren, Åsa Carlsson; Nilsson, Josef; Persson, Maria; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (D m,m ) and dose-to-water-in-medium (D w,m ). The relation between D m,m and D w,m for 192 Ir is the main goal of this study, in particular the dependence of D w,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: D m,m, D w,m (LCT), mean photon energy and photon fluence. D w,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between D m,m and D w,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between D w,m (SCT) and D w,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between D m,m and D w,m (SCT) mainly depend on tissue type, differences between D m,m and D w,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources. (paper)

  6. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer; Avaliacao da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jetro Pereira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina; Rosa, Luiz Antonio Ribeiro da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], e-mail: lrosa@ird.gov.br; Batista, Delano Valdivino Santos; Bardella, Lucia Helena [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil). Unit of Medical Physics; Carvalho, Arnaldo Rangel [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. of Thermoluminescent Dosimetry

    2009-03-15

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  7. High dose therapy with autologous stem cell support in malignant disorders

    International Nuclear Information System (INIS)

    Holte, H.; Kvaloey, S.O.; Engan, T.

    1996-01-01

    New biomedical knowledge may improve the diagnostic procedures and treatment provided by the Health Services, but at additional cost. In a social democratic health care system, the hospital budgets have no room for expensive, new procedures or treatments, unless these are funded through extra allocation from the central authorities. High dose therapy with autologous stem cell support in malignant disorders is an example of a new and promising, but rather expensive treatment, but its role in cancer therapy has yet to be established. The indications for testing high dose therapy with autologous stem cell support in various malignancies are discussed, with emphasis on the principles for deciding which categories of disease should have priority. The authors suggest some malignant disorder for which high dose therapy with stem cell support should be explored versus conventional treatment in randomized prospective trials. 8 refs., 1 tab

  8. High dose rate brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Koizumi, Masahiko; Ogawa, Kazuhiko; Furukawa, Souhei

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. (author)

  9. Prevention of incipient diabetic nephropathy by high-dose thiamine and benfotiamine.

    Science.gov (United States)

    Babaei-Jadidi, Roya; Karachalias, Nikolaos; Ahmed, Naila; Battah, Sinan; Thornalley, Paul J

    2003-08-01

    Accumulation of triosephosphates arising from high cytosolic glucose concentrations in hyperglycemia is the trigger for biochemical dysfunction leading to the development of diabetic nephropathy-a common complication of diabetes associated with a high risk of cardiovascular disease and mortality. Here we report that stimulation of the reductive pentosephosphate pathway by high-dose therapy with thiamine and the thiamine monophosphate derivative benfotiamine countered the accumulation of triosephosphates in experimental diabetes and inhibited the development of incipient nephropathy. High-dose thiamine and benfotiamine therapy increased transketolase expression in renal glomeruli, increased the conversion of triosephosphates to ribose-5-phosphate, and strongly inhibited the development of microalbuminuria. This was associated with decreased activation of protein kinase C and decreased protein glycation and oxidative stress-three major pathways of biochemical dysfunction in hyperglycemia. Benfotiamine also inhibited diabetes-induced hyperfiltration. This was achieved without change in elevated plasma glucose concentration and glycated hemoglobin in the diabetic state. High-dose thiamine and benfotiamine therapy is a potential novel strategy for the prevention of clinical diabetic nephropathy.

  10. Animal Welfare Groups Press for Limits on High School Research.

    Science.gov (United States)

    BioScience, 1979

    1979-01-01

    Discussions from the conference on "The Use of Animals in High School Biology Classes" are highlighted in this article. The list of science fair rules, which resulted from the conference, is included. (SA)

  11. In vivo dosimetry of high-dose fractionated irradiation in an experimental set-up with rats

    Energy Technology Data Exchange (ETDEWEB)

    Fortan, L; Van Hecke, H; Van Duyse, B; De Neve, W; De Meerleer, B [Ghent Rijksuniversiteit (Belgium). Kliniek voor Radiotherapie en Kerngeneeskunde; Pattyn, P; Van Renthergem, K [Ghent University (Belgium). Dept. of Surgery

    1995-12-01

    The feasibility to irradiate a limited section of a rat abdomen with well-defined edges was assessed. Because of the relative small volume involved, in vivo dosimetry with TLDs was necessary in providing us information about the accuracy of the irradiation method. Three to five days prior to the start of the radiotherapy treatment, two plastic strips - each containing a TLD-dosimeter (Harshaw TLD10 LiF rods, 1 mm dia x 6 mm) sealed in polyethylene tubing, and a lead bean - were implanted in the rat abdomen. The plastic strips made a closed loop around the bowel, through the mesenterium, and were fixed with a single stitch on the inner abdominal wall. One loop was made in the hepatic area; another was made in the lower abdomen, around the rectosigmoid. Conscious animals were irradiated using a purpose-build plexi-holder, with rear legs immobilised to avoid longitudinal movements. The implanted lead beans enabled us to simulate the rat prior to each radiation session. This way, the radiation field could be set up individually for each rat, in such way that the rectosigmoid area received full dose and the hepatic area received no irradiation dose at all. Irradiation was carried out, using 5 MV photons of a linear accelerator. Fifteen animals per group were irradiated according a conventional (2.0 Gy / fraction; 5 fractions / week) or a hyperfractionated (1.6 Gy / fraction; 2 daily fractions; 5 days / week) schedule, with different total doses. Prior to implantation, TLDs were individually calibrated and checked for stability. After removal from the abdomen . TLDs were tested again for accuracy. TLDs with an unacceptable read-out curve were rejected (about 2 to 4 TLDs per group of 15). The obtained accumulated doses - as determined by TLD read-outs-were comparable to the theoretical doses, indicating that fractionated radiation of small fields, with well defined mark off, in rats is feasible.

  12. In vivo dosimetry of high-dose fractionated irradiation in an experimental set-up with rats

    International Nuclear Information System (INIS)

    Fortan, L.; Van Hecke, H.; Van Duyse, B.; De Neve, W.; De Meerleer, B.; Pattyn, P.; Van Renthergem, K.

    1995-01-01

    The feasibility to irradiate a limited section of a rat abdomen with well-defined edges was assessed. Because of the relative small volume involved, in vivo dosimetry with TLDs was necessary in providing us information about the accuracy of the irradiation method. Three to five days prior to the start of the radiotherapy treatment, two plastic strips - each containing a TLD-dosimeter (Harshaw TLD10 LiF rods, 1 mm dia x 6 mm) sealed in polyethylene tubing, and a lead bean - were implanted in the rat abdomen. The plastic strips made a closed loop around the bowel, through the mesenterium, and were fixed with a single stitch on the inner abdominal wall. One loop was made in the hepatic area; another was made in the lower abdomen, around the rectosigmoid. Conscious animals were irradiated using a purpose-build plexi-holder, with rear legs immobilised to avoid longitudinal movements. The implanted lead beans enabled us to simulate the rat prior to each radiation session. This way, the radiation field could be set up individually for each rat, in such way that the rectosigmoid area received full dose and the hepatic area received no irradiation dose at all. Irradiation was carried out, using 5 MV photons of a linear accelerator. Fifteen animals per group were irradiated according a conventional (2.0 Gy / fraction; 5 fractions / week) or a hyperfractionated (1.6 Gy / fraction; 2 daily fractions; 5 days / week) schedule, with different total doses. Prior to implantation, TLDs were individually calibrated and checked for stability. After removal from the abdomen . TLDs were tested again for accuracy. TLDs with an unacceptable read-out curve were rejected (about 2 to 4 TLDs per group of 15). The obtained accumulated doses - as determined by TLD read-outs-were comparable to the theoretical doses, indicating that fractionated radiation of small fields, with well defined mark off, in rats is feasible

  13. Dose characteristics of high-energy electrons, muons and photons

    International Nuclear Information System (INIS)

    Britvich, G.I.; Krupnyj, G.I.; Peleshko, V.N.; Rastsvetalov, Ya.N.

    1980-01-01

    Differential distribution of energy release at different depth of tissue-equivalent phantoms (plexiglas, polystyrene, polyethylene) at the energy of incident electrons, muons of 0.2-40 GeV and photons with the mean energy of 3.6 GeV are measured. The error of experimental results does not exceed 7%. On the basis of the data obtained dose characteristics of electrons, muons and photons for standard geometry are estimated. For all types of irradiation the maximum value of specific equivalent dose, nremxcm 2 /part. is presented. It is shown that published values of specific equivalent dose of electron radiation are higher in all the investigated energy range from 0.2 to 40 GeV, and for muon radiation a good agreement with the present experiment is observed. The highly precise results obtained which cover the wide dynamic range according to the energy of incident particles can serve as the basis for reconsidering the existing recommendations for dose characteristics of electron radiation [ru

  14. Comparison of fixed low dose versus high dose radioactive iodine for the treatment of hyperthyroidism: retrospective multifactorial analysis impacting the outcome of therapy

    International Nuclear Information System (INIS)

    Suresh Kumar, A.C.; Malhotra, G.; Basu, S.; Asopa, R.V.

    2010-01-01

    Full text: Radioactive iodine ( 131 I) as a fixed dose protocol is widely used for treatment of hyperthyroidism. However, there is no consensus on the best optimum dose for an individual patient. The objectives of this study were to observe the outcome of 131 I therapy in patients of primary hyperthyroidism in relation to fixed low dose versus high dose regimen, impact of antithyroid drugs and influence of thyroid gland size on therapy outcome. Materials and Methods: Study design: Retrospective analysis. Study group included 287 diagnosed patients of primary hyperthyroidism who had undergone 131 I therapy for the first time (68 M, 219 F; Mean age ± S.D.: 43.84 ± 12.53). All patients with low RAIU, thyrocardiac disease were excluded. Details of antithyroid (ATD) drug treatment were recorded. Analysis was done from 2002 till patients became euthyroid/hypothyroid or until January 2010. Each patient's response was evaluated initially at 6 weeks and thereafter every three months. Appropriate statistical tests were applied to compare treatment response between the groups. A P value<0.05 was considered significant. Results: Of 287 patients, 209 patients had been administered low dose (Mean ± S.D.: 4.68 ± 0.62 mCi) while 78 patients had received high dose (Mean ± S.D.: 9.15 ± 1.05 mCi) of radioiodine. 57.9% (121/ 209) patients in the low dose group responded as compared to 75.6% (59/78) in high dose group after a follow up of more than 36 months. Similarly, among patients with and without antithyroid drug treatment, grade II and above goiters the response rates were significantly higher for high dose group as compared to low dose group. Conclusion: We suggest that high dose radioiodine treatment with 8 to 10 mCi is effective in treating hyperthyroidism in patients with a better success rate than the low dose treatment with 3 to 5 mCi. This is also likely to be helpful in patients who have not received antithyroid drugs. It appears that clinically relevant

  15. High-dose preoperative chemoradiotherapy in esophageal cancer patients does not increase postoperative pulmonary complications: Correlation with dose-volume histogram parameters

    International Nuclear Information System (INIS)

    Hurmuzlu, Meysan; Ovrebo, Kjell; Wentzel-Larsen, Tore; Muren, Ludvig Paul; Viste, Asgaut; Smaaland, Rune

    2010-01-01

    Purpose: To investigate the association of high-dose preoperative chemoradiotherapy (CRT) and dose-volume histogram (DVH) parameters of lungs with incidence of postoperative pulmonary complications and to identify predictive clinical factors of pulmonary complications. Methods: Data of 65 patients were collected retrospectively. Thirty-five patients underwent transthoracic esophagectomy (TTE) alone and 30 received cisplatin and 5-fluorouracil, concomitant with radiotherapy, median dose 66 Gy, and followed by TTE. From the DVH for each lung alone and for both lungs together as one organ we generated total lung volume, mean radiotherapy dose, relative and absolute volumes receiving more than a threshold dose, and relative and absolute volumes receiving less than a threshold dose. Postoperative pulmonary complications were defined as pneumonia or respiratory failure. Results: Sixty percent of the patients in the TTE alone group had postoperative pulmonary complications versus 63% in the CRT + TTE group. Postoperative mortality was 8.6% and 16.7% in the respective patient groups (p = NS). None of the DVH parameters was associated with postoperative pulmonary complications. Squamous cell carcinoma was an adverse factor related to increased postoperative pulmonary complications. Conclusion: High-dose preoperative CRT was not associated with increased postoperative pulmonary complications in this cohort of esophageal cancer patients.

  16. Nutritional Value of Irradiated Animal Feed By-Products

    International Nuclear Information System (INIS)

    El-Din Farag, M.D.H.

    1998-01-01

    Animal feed by-products, widely used in animal diets, are sources of disease organisms for animals and for human beings. Salmonella is the principal genus of concern.Radiation treatment (radicidation, radurization) is a promising method of decontamination of feed ingredients. Commercial samples of fish, meat, and blood meals were sealed by heat in polyethylene bags and irradiated at dose levels of 5.0, 10, 20 and 50 kGy. Their chemical analysis were carried out according to A. O. A.C [1] and the total protein efficiency (TPE) of the three animal feed by-products was determined according to Wood ham (2) by using one day old Dokki-4 chicks. Radiation induced an insignificant effect on the chemical constituent of meals. Also, the same trend was observed with TPE of both fish and meat meals. However, irradiation treatments improved TPE values of irradiated blood meal samples. From the results, it could be concluded that irradiation of animal feed by-products up to a dose level of 50 Gy has no adverse effects on the nutritional value of animal feed by-products

  17. Low doses effects

    International Nuclear Information System (INIS)

    Tubiana, M.

    1997-01-01

    In this article is asked the question about a possible carcinogens effect of low dose irradiation. With epidemiological data, knowledge about the carcinogenesis, the professor Tubiana explains that in spite of experiments made on thousand or hundred of thousands animals it has not been possible to bring to the fore a carcinogens effect for low doses and then it is not reasonable to believe and let the population believe that low dose irradiation could lead to an increase of neoplasms and from this point of view any hardening of radiation protection standards could in fact, increase anguish about ionizing radiations. (N.C.)

  18. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

    Energy Technology Data Exchange (ETDEWEB)

    Deng Hua [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Kennedy, Christopher W [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Armour, Elwood [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Ford, Eric [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); McNutt, Todd [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Jiang Licai [OSMIC Inc., 1900 Taylor Rd., Auburn Hills, MI (United States); Wong, John [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States)

    2007-05-21

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min{sup -1} at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of {+-}5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.

  19. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system.

    Science.gov (United States)

    Deng, Hua; Kennedy, Christopher W; Armour, Elwood; Tryggestad, Erik; Ford, Eric; McNutt, Todd; Jiang, Licai; Wong, John

    2007-05-21

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min(-1) at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of +/-5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.

  20. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

    International Nuclear Information System (INIS)

    Deng Hua; Kennedy, Christopher W; Armour, Elwood; Tryggestad, Erik; Ford, Eric; McNutt, Todd; Jiang Licai; Wong, John

    2007-01-01

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min -1 at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of ±5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD

  1. Mefenamic Acid Induced Nephrotoxicity: An Animal Model

    Directory of Open Access Journals (Sweden)

    Muhammad Nazrul Somchit

    2014-12-01

    Full Text Available Purpose: Nonsteroidal anti-inflammatory drugs (NSAIDs are used for the treatment of many joint disorders, inflammation and to control pain. Numerous reports have indicated that NSAIDs are capable of producing nephrotoxicity in human. Therefore, the objective of this study was to evaluate mefenamic acid, a NSAID nephrotoxicity in an animal model. Methods: Mice were dosed intraperitoneally with mefenamic acid either as a single dose (100 or 200 mg/kg in 10% Dimethyl sulfoxide/Palm oil or as single daily doses for 14 days (50 or 100 mg/kg in 10% Dimethyl sulfoxide/Palm oil per day. Venous blood samples from mice during the dosing period were taken prior to and 14 days post-dosing from cardiac puncture into heparinized vials. Plasma blood urea nitrogen (BUN and creatinine activities were measured. Results: Single dose of mefenamic acid induced mild alteration of kidney histology mainly mild glomerular necrosis and tubular atrophy. Interestingly, chronic doses induced a dose dependent glomerular necrosis, massive degeneration, inflammation and tubular atrophy. Plasma blood urea nitrogen was statistically elevated in mice treated with mefenamic acid for 14 days similar to plasma creatinine. Conclusion: Results from this study suggest that mefenamic acid as with other NSAIDs capable of producing nephrotoxicity. Therefore, the study of the exact mechanism of mefenamic acid induced severe nephrotoxicity can be done in this animal model.

  2. Safety of higher dosages of Viscum album L. in animals and humans - systematic review of immune changes and safety parameters

    Directory of Open Access Journals (Sweden)

    Kiene Helmut

    2011-08-01

    Full Text Available Abstract Background Viscum album L extracts (VAE, mistletoe and isolated mistletoe lectins (ML have immunostimulating properties and a strong dose-dependent cytotoxic activity. They are frequently used in complementary cancer treatment, mainly to improve quality of life, but partly also to influence tumour growth, especially by injecting VAE locally and in high dosage. The question is raised whether these higher dosages can induce any harm or immunosuppressive effects. Methods Systematic review of all experiments and clinical studies investigating higher dosages of VAE in animals and humans (Viscum album > 1 mg in humans corresponding to > 0.02 mg/kg in animals or ML > 1 ng/kg and assessing immune parameters or infections or adverse drug reactions. Results 69 clinical studies and 48 animal experiments reported application of higher doses of VAE or ML and had assessed immune changes and/or harm. In these studies, Viscum album was applied in dosages up to 1500 mg in humans and 1400 mg/kg in animals, ML was applied up to 6.4 μg/kg in humans and in animals up to 14 μg/kg subcutaneously, 50 μg/kg nasally and 500 μg/kg orally. A variety of immune parameters showed fluctuating or rising outcomes, but no immunosuppressive effect. Side effects consisted mainly of dose-dependent flu-like symptoms (FLS, fever, local reactions at the injection site and various mild unspecific effects. Occasionally, allergic reactions were reported. After application of high doses of recombinant ML, reversible hepatotoxicity was observed in some cases. Conclusions Application of higher dosages of VAE or ML is not accompanied by immunosuppression; altogether VAE seems to exhibit low risk but should be monitored by clinicians when applied in high dosages.

  3. High-dose metoclopramide + lorazepam versus low-dose metoclopramide + lorazepam + dehydrobenzperidol in the treatment of cisplatin-induced nausea and vomiting

    DEFF Research Database (Denmark)

    Herrstedt, Jørn; Hannibal, J; Hallas, Jesper

    1991-01-01

    In a randomized double-blind, cross-over trial of 34 patients receiving cisplatin-based chemotherapy (20-100 mg/m2), the antiemetic effect of high-dose metoclopramide (HDM) (10 mg/kg iv. loading dose + 7 hours continuous infusion) + lorazepam (L) (2.5 mg x 4 po) was compared with low......-dose metoclopramide (LDM) (70 mg) + L (2.5 mg x 2 po) + dehydrobenzperidol (5 mg x 2 im). Among the 29 patients who completed the cross-over, HDM significantly reduced the number of vomiting episodes (p = 0.002) and the degree of nausea (p = 0.004). Seventeen patients preferred the HDM and 4 the LDM regimen (p = 0.......01). Sedation was seen in all but 1 patient, and was graded as severe in 6 patients receiving the HDM and in 2 patients receiving the LDM regimen. No extrapyramidal adverse reactions were seen. We conclude that high-dose metoclopramide + lorazepam is a safe antiemetic regimen and significantly superior to low...

  4. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  5. Radiotherapy after high-dose chemotherapy and peripheral blood stem cell support in high-risk breast cancer

    International Nuclear Information System (INIS)

    Hoeller, Ulrike; Heide, Juergen; Kroeger, Nicolaus; Krueger, William; Jaenicke, Fritz; Alberti, Winfried

    2002-01-01

    Purpose: To assess the toxicity and efficacy of radiotherapy with respect to locoregional control after adjuvant high-dose chemotherapy for patients with breast cancer. At first, radiotherapy was withheld because of toxicity concerns, but it was introduced in 1995 because of reported high locoregional relapse rates. Methods and Materials: Between 1992 and 1998, 40 patients with Stage II-III high-risk breast cancer received adjuvant high-dose chemotherapy consisting of thiotepa, mitoxantrone, and cyclophosphamide and peripheral blood stem cell support after four cycles of induction chemotherapy. The chest wall or breast, as well as the supraclavicular nodes, were irradiated with electrons and photons to a median dose of 50.4 Gy in 20 patients. Six additional patients received only supraclavicular irradiation to a median dose of 50.4 Gy. Acute toxicity was scored clinically. Pulmonary function tests were performed in 14 irradiated patients before high-dose chemotherapy and 1.1-4.4 years (median 1.6) after irradiation. The median follow-up time of living patients was 33 vs. 67 months in irradiated (n=26) and nonirradiated (n=14) patients, respectively. Results: G2 and G3 hematologic toxicity occurred in 1 patient each. No clinical pneumonitis or clinical impairment of lung function was observed. After 1-2 years, the lung function tests showed only minor changes in 4 patients. The 3-year locoregional control rate was 92% in the irradiated patients vs. 58% in the nonirradiated patients (p=0.049, actuarial analysis). Conclusion: In this series, adjuvant radiotherapy after adjuvant chemotherapy for breast cancer appeared well tolerated, with improved local regional control and without significant side effects. Longer follow-up and more patient accrual, as well as Phase III trials, are necessary for confirmation

  6. The biological effects of high dose total body irradiation in beagle dogs

    International Nuclear Information System (INIS)

    Luo Qingliang; Liu Xiaolan; Hao Jing; Xiong Guolin; Dong Bo; Zhao Zhenhu; Xia Zhengbiao; Qiu Liling; Mao Bingzhi

    2002-01-01

    Objective: To evaluate the biological effects of Beagle dogs irradiated by γ-rays at different doses. Methods: All Beagle dogs were divided into six groups and were subjected respectively to total-body irradiation (TBI) with a single dose of 6.5, 5.5, 5.0, 4.5, 3, 5 and 2.5 Gy γ-rays delivered by 60 Co sources at 7.224 x 10 -2 C/kg per minute. The general condition, blood cell counts and bone marrow cell CFC assays were observed. Results: Vomiting occurred at 0.5 to 2 hours after TBI in all groups. In 6.5 Gy group 3/5 dogs had blood-watery stool and 1/5 in 5.5 Gy group had watery stool. Diarrhea occurred in all other animals. Only one dog in 2.5 Gy group survived, all of others died. in order of decreasing irradiation dosage, the average survival time was 5.0, 8.0, 9.3, 9.5, 10.5 and 14.1 days, respectively. Conclusions: According to the clinical symptoms, leukocyte count and survival time of the dogs, the irradiation dose which will induce very severe hematopoietic radiation syndrome in Beagle dogs is 4.5 to 5.0 Gy

  7. Low dose X -ray effects on catalase activity in animal tissue

    Science.gov (United States)

    Focea, R.; Nadejde, C.; Creanga, D.; Luchian, T.

    2012-12-01

    This study was intended to investigate the effect of low-dose X ray-irradiation upon the activity of catalase (CAT) in freshly excised chicken tissues (liver, kidney, brain, muscle). The tissue samples were irradiated with 0.5Gy and 2Gy respectively, in a 6 MV photon beam produced by a clinical linear accelerator (VARIAN CLINAC 2100SC). The dose rate was of 260.88cGy/min. at 100 cm source to sample distance. The catalase level was assayed spectrophotometrically, based on reaction kinetics, using a catalase UV assay kit (SIGMA). Catalase increased activity in various tissue samples exposed to the studied X ray doses (for example with 24 % in the liver cells, pbonds that ensure the specificity of CAT active site) but the resulted balance of the two concurrent processes indicates the cell ability of decomposing the hydrogen peroxide-with benefits for the cell physiology restoration for the chosen low dose radiation.

  8. Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Jackson, Andrew; Hunt, Margie; Bilsky, Mark; Yamada, Yoshiya

    2012-01-01

    Purpose: To report the esophageal toxicity from single-fraction paraspinal stereotactic radiosurgery (SRS) and identify dosimetric and clinical risk factors for toxicity. Methods and Materials: A total of 204 spinal metastases abutting the esophagus (182 patients) were treated with high-dose single-fraction SRS during 2003-2010. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 4.0. Dose-volume histograms were combined to generate a comprehensive atlas of complication incidence that identifies risk factors for toxicity. Correlation of dose-volume factors with esophageal toxicity was assessed using Fisher’s exact test and logistic regression. Clinical factors were correlated with toxicity. Results: The median dose to the planning treatment volume was 24 Gy. Median follow-up was 12 months (range, 3-81). There were 31 (15%) acute and 24 (12%) late esophageal toxicities. The rate of grade ≥3 acute or late toxicity was 6.8% (14 patients). Fisher’s exact test resulted in significant median splits for grade ≥3 toxicity at V12 = 3.78 cm 3 (relative risk [RR] 3.7, P=.05), V15 = 1.87 cm 3 (RR 13, P=.0013), V20 = 0.11 cm 3 (RR 6, P=0.01), and V22 = 0.0 cm 3 (RR 13, P=.0013). The median split for D2.5 cm 3 (14.02 Gy) was also a significant predictor of toxicity (RR 6; P=.01). A highly significant logistic regression model was generated on the basis of D2.5 cm 3 . One hundred percent (n = 7) of grade ≥4 toxicities were associated with radiation recall reactions after doxorubicin or gemcitabine chemotherapy or iatrogenic manipulation of the irradiated esophagus. Conclusions: High-dose, single-fraction paraspinal SRS has a low rate of grade ≥3 esophageal toxicity. Severe esophageal toxicity is minimized with careful attention to esophageal doses during treatment planning. Iatrogenic manipulation of the irradiated esophagus and systemic agents classically associated with radiation recall reactions are

  9. High-dose ascorbic acid decreases cholesterolemic factors of an atherogenic diet in guinea pigs.

    Science.gov (United States)

    Filis, Konstantinos; Anastassopoulou, Aikaterini; Sigala, Fragiska; Theodorou, Dimitrios; Manouras, Andreas; Leandros, Emanouel; Sigalas, Panagiotis; Hepp, Wolfgang; Bramis, John

    2007-03-01

    The study evaluates the effect of a high supplemental dose of ascorbic acid (AA) on plasma concentrations of total cholesterol (TC), triglycerides (TG), total lipids (TL), and lipoprotein fractions high-density, very-low-density-, and low-density lipoprotein (HDL, VLDL, LDL) in guinea pigs fed with atherogenic diet. Group I consisted of 5 normally fed guinea pigs plus a low dose of AA (1 mg/100 g/day), group II consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a low dose of AA (1 mg/100 g/day), and group III consisted of 7 guinea pigs fed with food enriched with 2% cholesterol plus a high dose of AA (30 mg/100 g/day). Cholesterolemic factors concentrations were determined after nine weeks. Concentrations of TC, TG, TL, LDL, and VLDL were increased in group II compared to group I (p < 0.01 for all differences). Supplementation with a high dose of AA resulted in decreased concentrations of TC (p < 0.01), TG (p < 0.01), TL (p < 0.01), and LDL (p < 0.01) in group III compared to group II. Additionally, concentration of HDL was increased in group III compared to group II (p < 0.01). High-dose AA supplementation to an atherogenic diet decreases concentrations of TC, TG, TL, and LDL and increases concentration of HDL compared to low-dose AA.

  10. Split high-dose oral levothyroxine treatment as a successful therapy option in myxedema coma.

    Science.gov (United States)

    Charoensri, Suranut; Sriphrapradang, Chutintorn; Nimitphong, Hataikarn

    2017-10-01

    High-dose intravenous thyroxine (T4) is the preferable treatment for myxedema coma. We describe the clinical course of a 69-year-old man who presented with myxedema coma and received oral levothyroxine (LT4) therapy (1 mg) in a split dose. This suggests split high-dose oral LT4 as a therapeutic option in myxedema coma.

  11. Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma

    Energy Technology Data Exchange (ETDEWEB)

    Karunamuni, Roshan [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Bartsch, Hauke; White, Nathan S. [Department of Radiology, University of California San Diego, La Jolla, California (United States); Moiseenko, Vitali; Carmona, Ruben; Marshall, Deborah C.; Seibert, Tyler M. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); McDonald, Carrie R. [Department of Psychiatry, University of California San Diego, La Jolla, California (United States); Farid, Nikdokht; Krishnan, Anithapriya; Kuperman, Joshua [Department of Radiology, University of California San Diego, La Jolla, California (United States); Mell, Loren [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Brewer, James B.; Dale, Anders M. [Department of Radiology, University of California San Diego, La Jolla, California (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States)

    2016-02-01

    Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thickness between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.

  12. Second malignancies in high-dose areas of previous tumor radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Welte, Birgitta; Suhr, Peter; Bottke, Dirk; Bartkowiak, Detlef; Wiegel, Thomas [Dept. of Radiotherapy and Radiation Oncology, Univ. of Ulm (Germany); Doerr, Wolfgang [Dept. of Radiotherapy and Radiation Oncology, Radiobiology Lab., Univ. of Technology Dresden (Germany); Trott, Klaus Ruediger [UCL Cancer Centre, Univ. Coll. London (United Kingdom)

    2010-03-15

    Purpose: To characterize second tumors that developed in or near the high-dose areas of a previous radiotherapy, regarding their frequency, entities, latency, and dose dependence. Patients and Methods: 9,995/15,449 tumor patients of the Radiation Oncology Department in Ulm, Germany, treated between 1981 and 2003, survived at least 1 year after radiotherapy. By long-term follow-up and review of treatment documentation, 100 of them were identified who developed an independent second cancer in or near the irradiated first tumor site. Results: Major primary malignancies were breast cancer (27%), lymphoma (24%), and pelvic gynecologic tumors (17%). Main second tumors were carcinomas of the upper (18%) and lower (12%) gastrointestinal tract, head and neck tumors (10%), lymphoma (10%), breast cancer (9%), sarcoma (9%), and lung cancer (8%). Overall median second tumor latency was 7.4 years (1-42 years). For colorectal cancer it was 3.5 and for leukemia 4.3 years, but for sarcoma 11.7 and for breast cancer 17.1 years. The relatively frequent second tumors of the upper gastrointestinal tract were associated with median radiation doses of 24 Gy. By contrast, second colorectal cancer and sarcoma developed after median doses of 50 Gy. Conclusion: The 5- and 15-year probability to develop a histopathologically independent second tumor in or near the irradiated first tumor site, i.e., after intermediate or high radiation doses, was 0.5% and 2.2%, respectively. To identify potentially radiogenic second malignancies, a follow-up far beyond 5 years is mandatory. The incidence and potential dose-response relationship intermediate will be analyzed by a case-case and a case-control study of the Ulm data. (orig.)

  13. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    International Nuclear Information System (INIS)

    Sandilos, Panagiotis; Baras, Panagiotis; Georgiou, Evangelos; Dardoufas, Konstantinos; Karaiskos, Pantelis; Papagiannis, Panagiotis; Paschalis, Theodoros; Tatsis, Elias; Torrens, Michael; Vlahos, Lampros

    2006-01-01

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an 192 Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications

  14. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    Energy Technology Data Exchange (ETDEWEB)

    Sandilos, Panagiotis [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Baras, Panagiotis [Philips Hellas Medical Systems, 44 Kifissias Ave., Maroussi 151 25, Athens (Greece); Georgiou, Evangelos [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece); Dardoufas, Konstantinos [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Karaiskos, Pantelis [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece)]. E-mail: p.karaiskos@hygeia.gr; Papagiannis, Panagiotis [Physics Department, Nuclear and Particle Physics Section, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Paschalis, Theodoros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Tatsis, Elias [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Torrens, Michael [Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Vlahos, Lampros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece)

    2006-12-20

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an {sup 192}Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications.

  15. Can high-dose fotemustine reverse MGMT resistance in glioblastoma multiforme?

    Science.gov (United States)

    Gallo, Chiara; Buonerba, Carlo; Di Lorenzo, Giuseppe; Romeo, Valeria; De Placido, Sabino; Marinelli, Alfredo

    2010-11-01

    Glioblastoma multiforme (GBM), the highest grade malignant glioma, is associated with a grim prognosis-median overall survival is in the range 12-15 months, despite optimum treatment. Surgery to the maximum possible extent, external beam radiotherapy, and systemic temozolomide chemotherapy are current standard treatments for newly diagnosed GBM, with intracerebral delivery of carmustine wafers (Gliadel). Unfortunately, the effectiveness of chemotherapy can be hampered by the DNA repair enzyme O6-methylguanine methyltransferase (MGMT), which confers resistance both to temozolomide and nitrosoureas, for example fotemustine and carmustine. MGMT activity can be measured by PCR and immunohistochemistry, with the former being the current validated technique. High-dose chemotherapy can deplete MGMT levels in GBM cells and has proved feasible in various trials on temozolomide, in both newly diagnosed and recurrent GBM. We here report the unique case of a GBM patient, with high MGMT expression by immunohistochemistry, who underwent an experimental, high-dose fotemustine schedule after surgery and radiotherapy. Although treatment caused two episodes of grade 3-4 thrombocytopenia, a complete response and survival of more than three years were achieved, with a 30% increase in dose intensity compared with the standard fotemustine schedule.

  16. Multi-mycotoxin analysis of animal feed and animal-derived food using LC-MS/MS system with timed and highly selective reaction monitoring.

    Science.gov (United States)

    Zhao, Zhiyong; Liu, Na; Yang, Lingchen; Deng, Yifeng; Wang, Jianhua; Song, Suquan; Lin, Shanhai; Wu, Aibo; Zhou, Zhenlei; Hou, Jiafa

    2015-09-01

    Mycotoxins have the potential to enter the human food chain through carry-over of contaminants from feed into animal-derived products. The objective of the study was to develop a reliable and sensitive method for the analysis of 30 mycotoxins in animal feed and animal-derived food (meat, edible animal tissues, and milk) using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In the study, three extraction procedures, as well as various cleanup procedures, were evaluated to select the most suitable sample preparation procedure for different sample matrices. In addition, timed and highly selective reaction monitoring on LC-MS/MS was used to filter out isobaric matrix interferences. The performance characteristics (linearity, sensitivity, recovery, precision, and specificity) of the method were determined according to Commission Decision 2002/657/EC and 401/2006/EC. The established method was successfully applied to screening of mycotoxins in animal feed and animal-derived food. The results indicated that mycotoxin contamination in feed directly influenced the presence of mycotoxin in animal-derived food. Graphical abstract Multi-mycotoxin analysis of animal feed and animal-derived food using LC-MS/MS.

  17. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  18. Bronchial mucosal tolerance following high dose rate endobronchial brachytherapy: clinical and laboratory correlates in late complication assessment of fatal hemoptysis

    International Nuclear Information System (INIS)

    Chen, Y.Y.; McDonald, S.; Nakamura, C.; Philips, A.; Ojomo, Karanita; Hernady, E.; Williams, J. P.; Smudzin, T.; Johnstone, D.; Feins, R.; Speiser, B.L.; Rubin, P.

    1996-01-01

    Purpose: This study reviews treatment related late complications following high dose rate endobronchial brachytherapy (HDR-EB) for primary lung cancers. Radiation dose contribution from HDR-EB treatment alone, or combined HDR-EB and external beam (EBRT) were analyzed in relation to the linear representation of the tracheobronchial anatomy. Results were presented in a dose volume histogram (DVH) analysis for the risk estimate of late complications from HDR-EB. Bronchial mucosal tolerance is estimated from the clinical experience study and histopathologic changes in laboratory animals treated with HDR-EB. Methods: 1.) There were forty one patients with primary lung cancer received HDR-EB as part of the radiation treatment between December 1990 and June 1994. Six of these developed late complications manifested as either fatal hemoptysis or endobronchial deposition of fibrinous material/bronchial stenosis. Treatment planning films were reviewed to map the volume treated with HDR-EB and EBRT along the tracheobronchial segments. DVH was constructed and compared for patients with and without late complications. Other clinical parameters of interest which were analyzed included: dose per fraction, EBRT total dose, HDR total dose, combined EBRT and HDR total dose, number of catheters per treatment, and points of prescriptions for HDR-EB. 2.) Forty four New Zealand White rabbits underwent HDR-EB of the major airway to a treatment length of 2 cm (1 cm above and below the carina) to a single fraction dose of 10 Gy, 30 Gy, or 50 Gy. Histopathologic changes were examined at 7, 14, 28, and 56 days post-treatment and compared with the control rabbits which received no irradiation. Results: 1.) The late complication rate is 14.5% with three patients developing fibrinous deposits/bronchial stenosis and four patients who experienced fatal hemoptysis in a total of six patients. There is a significant difference in DVH of HDR-EB treatment in the tracheobronchial high dose region

  19. Prehospital high-dose sublingual nitroglycerin rarely causes hypotension.

    Science.gov (United States)

    Clemency, Brian M; Thompson, Jeffrey J; Tundo, Gina N; Lindstrom, Heather A

    2013-10-01

    High-dose intravenous nitroglycerin is a common in-hospital treatment for respiratory distress due to congestive heart failure (CHF) with hypertension. Intravenous (IV) nitroglycerin administration is impractical in the prehospital setting. In 2011, a new regional Emergency Medical Services (EMS) protocol was introduced allowing advanced providers to treat CHF with high-dose oral nitroglycerin. The protocol calls for patients to be treated with two sublingual tabs (0.8 mg) when systolic blood pressure (SBP) was >160 mm Hg, or three sublingual tabs (1.2 mg) when SBP was >200 mm Hg, every five minutes as needed. Hypothesis/Problem To assess the protocol's safety, the incidence of hypotension following prehospital administration of multiple simultaneous nitroglycerin (MSN) tabs by EMS providers was studied. This study was a retrospective cohort study of patients from a single commercial EMS agency over a 6-month period. Records from patients with at least one administration of MSN were reviewed. For each administration, the first documented vital signs pre- and post-administration were compared. Administrations were excluded if pre- or post-administration vital signs were missing. One hundred case-patients had at least one MSN administration by an advanced provider during the study period. Twenty-five case-patients were excluded due to incomplete vital signs. Seventy-five case-patients with 95 individual MSN administrations were included for analysis. There were 65 administrations of two tabs, 29 administrations of three tabs, and one administration of four tabs. The mean change in SBP following MSN was -14.7 mm Hg (SD = 30.7; range, +59 to -132). Three administrations had documented systolic hypotension in the post-administration vital signs (97/71, 78/50 and 66/47). All three patients were over 65 years old, were administered two tabs, had documented improved respiratory status, and had repeat SBP of at least 100. The incidence of hypotension following MSN

  20. Characterization of Thymol blue Radiochromic dosimeters for high dose applications

    Directory of Open Access Journals (Sweden)

    Feras M. Aldweri

    2018-03-01

    Full Text Available Thymol blue (TB solutions and Thymol blue Polyvinyl Alcohol (TB-PVA films have been introduced as Radiochromic dosimeter for high dose applications. The dosimeters were irradiated with gamma ray (60Co source from 5 to 30 kGy for film, and from 0.150 kGy to 4 kGy for solution. The optical density of unirradiated and irradiated TB solution as well as TB-PVA film dosimeters were studied in terms of absorbance at 434 nm using UV/VIS spectrophotometer. The effects of scan temperature, light pre-gamma irradiation, dose rate, relative humidity and stability of the absorbance of solutions and films after irradiation were investigated. We found the dose sensitivity of TB solution and TB-PVA film dosimeters increases significantly with increases of the absorbed dose as well as with the increases of TB dye concentrations. The useful dose range of developed TB solutions and TB-PVA films dosimeters is in the range 0.125–1 kGy and of 5–20 kGy, respectively. Keywords: Dose sensitivity, Radio-chromic dosimeter, Thymol blue, Absorbance, Concentrations

  1. Metabolism of americium-241 in dairy animals

    International Nuclear Information System (INIS)

    Sutton, W.W.; Patzer, R.G.; Mullen, A.A.; Hahn, P.B.; Potter, G.D.

    1978-01-01

    Groups of lactating cows and goats were used to examine americium-241 metabolism in dairy animals. Following either single oral or intravenous nuclide doses, samples of milk, urine, blood, and feces were taken over a 168-hour collection period, and the americium concentrations were determined by gamma counting. Gastrointestinal uptake of americium by cows and goats was estimated to be 0.014 and 0.016% of the oral dose, respectively. The cumulative percentage of oral dose transported to milk and urine was 4.4 x 10 -4 and 1.1 x 10 -3 , respectively, for cows and 5.6 x 10 -4 and 1.2 x 10 -3 , respectively, for goats. Plasma concentrations of americium decreased rapidly following all intravenous injections. The average percentage of injected americium transferred to milk, urine, and feces was 3, 6, and 2%, respectively, for cows, and 2, 4, and 2%, respectively, for goats. In both intravenously dosed groups, approximately 30% of all americium released from the body was found in the urine during the first 24 hours after injection. All animals were sacrificed 8 to 9 days after dosing. Bovine bone retained the greatest fraction of the administered dose followed by liver and kidney. However, liver retained the greatest amount of americium in the goats following both oral and intravenous doses. Comparisons are presented between americium-241 and plutonium-238 transport in dairy cows

  2. High-dose anti-histamine use and risk factors in children with urticaria.

    Science.gov (United States)

    Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu

    2016-12-01

    The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=-0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (p<0.001, p=0.015). High UAS7 score (OR: 1.09; CI 95%: [1.03-1.15]) and basopenia (OR: 6.77; CI 95%: [2.01-22.75]) were associated with the requirement of high-dose H1-AH in children with chronic urticaria. The requirement of high-dose H1-antihistamines was higher with children's increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines.

  3. Surface applicators for high dose rate brachytherapy in AIDS-related kaposi's sarcoma

    International Nuclear Information System (INIS)

    Evans, Michael D.C.; Yassa, Mariam; Podgorsak, Ervin B.; Roman, Ted N.; Schreiner, L. John; Souhami, Luis

    1997-01-01

    Purpose: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. Methods and Materials: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. Results: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. Conclusion: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion

  4. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  5. Dose-response relationship in clinical oncology

    International Nuclear Information System (INIS)

    Gehan, E.A.

    1984-01-01

    The relationship of dose (and dose rate) to response and toxicity in clinical oncology is reviewed. The concepts expressed by some authors in dose-response studies in animal and human systems are reviewed briefly. Dose rate and tactics of conducting clinical studies are reviewed for both radiotherapy and various types of chemotherapeutic treatment. Examples are given from clinical studies in Hodgkin's disease, acute leukemia, and breast cancer that may prove useful in planning future clinical studies

  6. Influence of high doses of manganese, copper, zinc and boron on some legumes

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, G

    1973-01-01

    Macroscopic and microscopic examinations showed the following symptoms of an excess in trace elements: (1) High doses of manganese (50-150 ppm) cause dark patches (chloroplast accumulation) in young leaves, and necrosis of the leaf margin (MnO/sub 2/ accumulation) in older leaves. The roots become brown and die off. Roots newly formed in compensation are strikingly light-colored. (2) High doses of copper (5-40 ppm) cause iron deficiency chlorosis. A large number of side roots develop in quick succession as a result of damage to the root apex, so that a thick tangle of roots is formed. (3) High doses of zinc (50-150 ppm) bring about dark green, very brittle young leaves with very high ZnO content. The older leaves become red and then yellow. The roots remain stunted because of inhibited growth in length. (4) High doses of boron (30-90 ppm) cause a leaf necrosis which proceeds in the sequence tip, margin, lamina. The roots are not affected in any characteristic way. They become brown and die off.

  7. Non-animal methodologies within biomedical research and toxicity testing.

    Science.gov (United States)

    Knight, Andrew

    2008-01-01

    Laboratory animal models are limited by scientific constraints on human applicability, and increasing regulatory restrictions, driven by social concerns. Reliance on laboratory animals also incurs marked - and in some cases, prohibitive - logistical challenges, within high-throughput chemical testing programmes, such as those currently underway within Europe and the US. However, a range of non-animal methodologies is available within biomedical research and toxicity testing. These include: mechanisms to enhance the sharing and assessment of existing data prior to conducting further studies, and physicochemical evaluation and computerised modelling, including the use of structure-activity relationships and expert systems. Minimally-sentient animals from lower phylogenetic orders or early developmental vertebral stages may be used, as well as microorganisms and higher plants. A variety of tissue cultures, including immortalised cell lines, embryonic and adult stem cells, and organotypic cultures, are also available. In vitro assays utilising bacterial, yeast, protozoal, mammalian or human cell cultures exist for a wide range of toxic and other endpoints. These may be static or perfused, and may be used individually, or combined within test batteries. Human hepatocyte cultures and metabolic activation systems offer potential assessment of metabolite activity and organ-organ interaction. Microarray technology may allow genetic expression profiling, increasing the speed of toxin detection, well prior to more invasive endpoints. Enhanced human clinical trials utilising micro- dosing, staggered dosing, and more representative study populations and durations, as well as surrogate human tissues, advanced imaging modalities and human epidemiological, sociological and psycho- logical studies, may increase our understanding of illness aetiology and pathogenesis, and facilitate the development of safe and effective pharmacologic interventions. Particularly when human tissues

  8. Radiation dose in the high background radiation area in Kerala, India.

    Science.gov (United States)

    Christa, E P; Jojo, P J; Vaidyan, V K; Anilkumar, S; Eappen, K P

    2012-03-01

    A systematic radiological survey has been carried out in the region of high-background radiation area in Kollam district of Kerala to define the natural gamma-radiation levels. One hundred and forty seven soil samples from high-background radiation areas and five samples from normal background region were collected as per standard sampling procedures and were analysed for (238)U, (232)Th and (40)K by gamma-ray spectroscopy. External gamma dose rates at all sampling locations were also measured using a survey meter. The activities of (238)U, (232)Th and (40)K was found to vary from 17 to 3081 Bq kg(-1), 54 to 11976 Bq kg(-1) and BDL (67.4 Bq kg(-1)) to 216 Bq kg(-1), respectively, in the study area. Such heterogeneous distribution of radionuclides in the region may be attributed to the deposition phenomenon of beach sand soil in the region. Radium equivalent activities were found high in several locations. External gamma dose rates estimated from the levels of radionuclides in soil had a range from 49 to 9244 nGy h(-1). The result of gamma dose rate measured at the sampling sites using survey meter showed an excellent correlation with dose rates computed from the natural radionuclides estimated from the soil samples.

  9. High-precision radiosurgical dose delivery by interlaced microbeam arrays of high-flux low-energy synchrotron X-rays.

    Directory of Open Access Journals (Sweden)

    Raphaël Serduc

    Full Text Available Microbeam Radiation Therapy (MRT is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy. Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 microm wide, spaced 200 microm on-center, 50 to 350 keV in energy range, targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm(3 in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing

  10. Myocardial protection induced by fentanyl in pigs exposed to high-dose adrenaline.

    Science.gov (United States)

    da Luz, Vinicius Fernando; Otsuki, Denise Aya; Gonzalez, Maria Margarita Castro; Negri, Elnara Marcia; Caldini, Elia Garcia; Damaceno-Rodrigues, Nilsa Regina; Malbouisson, Luiz Marcelo Sá; Viana, Bruno Gonçalves; Vane, Matheus Fachini; Carmona, Maria Jose Carvalho

    2015-10-01

    The use of high doses of adrenaline is common in critical patients, especially during cardiac arrest. During these situations, myocardial dysfunction can be a result of multiple factors, including adrenaline use. In addition, opioids have been shown to have anti-arrhythmic and anti-ischemic mechanisms that may confer cardiac protection. This study aimed to evaluate the effects of fentanyl on myocardial function in pigs exposed to high-dose adrenaline. After institutional ethics committee approval, 26 pigs were randomly allocated to receive either 20 μg/kg fentanyl (n = 10; fentanyl group) administered 5 min before five doses of adrenaline (20 μg/kg), equivalent-volume saline (n = 10; saline group) using the same adrenaline dosing protocol, or neither fentanyl nor adrenaline (n = 6; sham group). The fentanyl group showed lower levels of troponin at the end of the sixth hour compared with the saline group (1.91 ± 1.47 vs 5.44 ± 5.35 ng/mL, P = 0.019). Transmission electron microscopy and immunohistochemistry also showed less myocardial injury in the fentanyl group. The conclusion was reached that fentanyl attenuates myocardial injury caused by high-dose adrenaline without blunting the hemodynamic effect of adrenaline. © 2015 Wiley Publishing Asia Pty Ltd.

  11. Image-Guided Stereotactic Radiosurgery Using a Specially Designed High-Dose-Rate Linac

    International Nuclear Information System (INIS)

    Bayouth, John E.; Kaiser, Heather S.; Smith, Mark C.; Pennington, Edward C.; Anderson, Kathleen M. C.; Ryken, Timothy C.; Buatti, John M.

    2007-01-01

    Stereotactic radiosurgery and image-guided radiotherapy (IGRT) place enhanced demands on treatment delivery machines. In this study, we describe a high-dose-rate output accelerator as a part of our stereotactic IGRT delivery system. The linac is a Siemens Oncor without a flattening filter, and enables dose rates to reach 1000 monitor units (MUs) per minute. Even at this high-dose-rate, the linac dosimetry system remains robust; constancy, linearity, and beam energy remain within 1% for 3 to 1000 MU. Dose profiles for larger field sizes are not flat, but they are radially symmetric and, as such, able to be modeled by a treatment planning system. Target localization is performed via optical guidance utilizing a 3-dimensional (3D) ultrasound probe coupled to an array of 4 infrared light-emitting diodes. These diodes are identified by a fixed infrared camera system that determines diode position and, by extension, all objects imaged in the room coordinate system. This system provides sub-millimeter localization accuracy for cranial applications and better than 1.5 mm for extracranial applications. Because stereotactic IGRT can require significantly longer times for treatment delivery, the advantages of the high-dose-rate design and its direct impact on IGRT are discussed

  12. High dose rate brachytherapy in treatment of high grade astrocytomas

    International Nuclear Information System (INIS)

    Garcia-Alejo, R.; Delgado, J.M.; Cerro, E. del; Torres, J.J.; Martinez, R.

    1996-01-01

    From May 1994 to June 1995, 18 patients with high grade astrocytomas were entered prospectively on a selective protocol combining surgery, external beam radiotherapy, stereotactic interstitial implantation with HDR Iridium 192 and chemotherapy. Only those patients with tumor size 100cc or less average dimension, high grade astrocytoma, Karnofsky 70 or greater, unilateral, circumscribed, unifocal, tumor stable or responding to external radiation and supratentorial were included in the study. Ages ranged from 16 to 69 years. There were 13 males and 5 females. Surgery consisted of biopsy only in 3 patients, subtotal resection in 11, and gross total resection in 4 patients. Focal external beam radiation portals included the contrast enhancing mass on CT scan plus a 3 cm margin. The protocol called for minimum tumor dose of 60 Gy to be given in 2 Gy daily fractions. An interstitial brachytherapy boost was to be performed two weeks after the conclusion of external beam radiation. The dose was 30 Gy in 4 fractions. The authors analyze on basis on their personal experience, the possibilities and the limits offered by this therapeutic procedure in neuro-oncology. Using stereotactic techniques, interstitial brachytherapy of brain tumors was technically possible with negligible acute morbidity and mortality, and appeared to be effective and may provide for an increase in tumor control in selected cases

  13. High-dose versus low-dose local anaesthetic for transversus abdominis plane block post-Caesarean delivery analgesia: a meta-analysis.

    Science.gov (United States)

    Ng, S C; Habib, A S; Sodha, S; Carvalho, B; Sultan, P

    2018-02-01

    The optimal local-anaesthetic (LA) dose for transversus-abdominis-plane (TAP) block is unclear. In this meta-analysis, we aimed to determine whether TAP blocks for Caesarean delivery (CD) with low-dose (LD) LA demonstrated non-inferiority in terms of analgesic efficacy, compared with high-dose (HD) LA. A literature search was performed for randomised controlled trials examining the analgesic efficacy of TAP blocks vs control after CD. The different dosing used in these studies was classified as HD or LD (bupivacaine equivalents >50 or ≤50 mg per block side, respectively). The pooled results of each dose group vs control were indirectly compared using the Q test. The primary outcome was 24 h opioid consumption. Secondary outcomes included 6 and 24 h postoperative pain scores, time to first analgesia, 6 h opioid consumption, opioid-related side-effects, and maternal satisfaction. Fourteen studies consisting of 770 women (389 TAP and 381 control) were included. Compared with controls, the 24 h opioid consumption (milligram morphine equivalents) was lower in HD [mean difference (MD) 95% confidence interval (CI) -22.41 (-38.56, -6.26); P=0.007; I 2 =93%] and LD [MD 95% CI -16.29 (-29.74, -2.84); P=0.02; I 2 =98%] TAP groups. However, no differences were demonstrated between the HD and LD groups (P=0.57). There were also no differences between the HD and LD groups for the 6 h opioid consumption, time to first analgesia, 6 and 24 h pain scores, postoperative nausea and vomiting, pruritus, and maternal satisfaction. Low-dose TAP blocks for Caesarean delivery provide analgesia and opioid-sparing effects comparable with the high-dose blocks. This suggests that lower doses can be used to reduce local anaesthetic toxicity risk without compromising the analgesic efficacy. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  14. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  15. [High-dosed gestagen therapy of the metastatic mammary carcinoma (author's transl)].

    Science.gov (United States)

    Firusian, N; Becher, R

    1981-12-01

    Thirty patients with histologically proven metastatic mammary carcinoma were treated, after exhaustion of hormonal and cytostatic therapeutic means, with high-dosed medroxyprogesterone acetate (MPA) during a ten-day induction phase with 1000 mg MPAi.m. per day and then with 600 mg oral MPA per day. In eleven patients a complete or partial remission was achieved. The median period of remission comprised ten months. A positive relationship was found between the response to high-dosed MPA therapy and the length of free intervals. Side effects were tolerable.

  16. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  17. 77 FR 55414 - New Animal Drugs; Enrofloxacin; Tylvalosin

    Science.gov (United States)

    2012-09-10

    ... 556 [Docket No. FDA-2012-N-0002] New Animal Drugs; Enrofloxacin; Tylvalosin AGENCY: Food and Drug...Care BAYTRIL 100 Supplement adding 522.812 yes CE \\1\\ LLC, Animal (enrofloxacin) control of bovine... Enrofloxacin. * * * * * (e) * * * (2) * * * (i) Amount--(A) Single-dose therapy: For treatment of bovine...

  18. High gamma dose response of the electrical properties of polyethylene terephthalate thin films

    International Nuclear Information System (INIS)

    Radwan, R.M.

    2007-01-01

    Electrical properties of polyethylene terephthalate (PET), irradiated with gamma rays, have been investigated. The PET films were irradiated with high gamma dose levels in the range from 100 to 2000 kGy. The changes in the DC (σ DC ) and the ac (σ ac ) conductivities, with the dose, have been performed. The effect of gamma irradiation on the dielectric constant (ε') and loss (ε'') has been determined. Also, the dose dependence of the frequency exponent index (S), the resonance frequency (Fc) and the hopping frequency (ω P ) have been obtained. The obtained results show that increasing gamma dose leads to slight increase in σ DC , σ ac and ε', while no change was observed in ε'' value. Meanwhile, S, Fc and ω P are inversely proportional to the dose. Accordingly, the study suggests the possibility of using PET films in electronic components (capacitors, resistors, etc.), especially that operate at high gamma dose environments for the frequency independent applications

  19. A high dose dosimeter based polyvinyl chloride dyed with malachite green

    International Nuclear Information System (INIS)

    Kattan, M.; Daher, Y.; Alkassiri, H.

    2007-01-01

    Polyvinyl chloride film (PVC) dyed with malachite green has been studied for high dose radiation dosimetry using visible spectrophotometry. A linear relationship between the relative absorbance and the absorbed dose at the wavelength 628 nm in the range of 0-125 kGy was found. The effect of dose rate, irradiation temperature, film thickness and dye intensity were found not to influence the response. The effects of shelf-life and the post-irradiation storage in darkness and indirect daylight conditions on dosimetry performance were discussed. (author)

  20. Rift valley fever virus lacking the NSs and NSm genes is highly attenuated, confers protective immunity from virulent virus challenge, and allows for differential identification of infected and vaccinated animals.

    Science.gov (United States)

    Bird, Brian H; Albariño, César G; Hartman, Amy L; Erickson, Bobbie Rae; Ksiazek, Thomas G; Nichol, Stuart T

    2008-03-01

    Rift Valley fever (RVF) virus is a mosquito-borne human and veterinary pathogen associated with large outbreaks of severe disease throughout Africa and more recently the Arabian peninsula. Infection of livestock can result in sweeping "abortion storms" and high mortality among young animals. Human infection results in self-limiting febrile disease that in approximately 1 to 2% of patients progresses to more serious complications including hepatitis, encephalitis, and retinitis or a hemorrhagic syndrome with high fatality. The virus S segment-encoded NSs and the M segment-encoded NSm proteins are important virulence factors. The development of safe, effective vaccines and tools to screen and evaluate antiviral compounds is critical for future control strategies. Here, we report the successful reverse genetics generation of multiple recombinant enhanced green fluorescent protein-tagged RVF viruses containing either the full-length, complete virus genome or precise deletions of the NSs gene alone or the NSs/NSm genes in combination, thus creating attenuating deletions on multiple virus genome segments. These viruses were highly attenuated, with no detectable viremia or clinical illness observed with high challenge dosages (1.0 x 10(4) PFU) in the rat lethal disease model. A single-dose immunization regimen induced robust anti-RVF virus immunoglobulin G antibodies (titer, approximately 1:6,400) by day 26 postvaccination. All vaccinated animals that were subsequently challenged with a high dose of virulent RVF virus survived infection and could be serologically differentiated from naïve, experimentally infected animals by the lack of NSs antibodies. These rationally designed marker RVF vaccine viruses will be useful tools for in vitro screening of therapeutic compounds and will provide a basis for further development of RVF virus marker vaccines for use in endemic regions or following the natural or intentional introduction of the virus into previously unaffected areas.

  1. Neutron dose measurements with the GSI ball at high energy accelerators

    International Nuclear Information System (INIS)

    Fehrenbacher, G.; Gutermuth, F.; Radon, T.; Kozlova, E.

    2005-01-01

    Full text: At high energy particle accelerators the production of neutron radiation dominates radiation protection. For the radiation survey at accelerators there is a need for reliable detection systems (passive radiation monitors), which can measure the dose for a wide range of neutron energies independently on the beam pulse structure of the produced radiation. In this work a passive neutron dosemeter for the measurement of the ambient dose equivalent is presented. The dosemeter is suitable for measurements of the emerging neutron radiation at accelerators for the whole energy range up to about 10 GeV. The dosemeter consists of a polyethylene sphere, TL elements (pairs of TLD600/700) and an additional lead layer (PE/Pb) in neutron fields at high energy accelerators is investigated in this work. Results of dose measurements which were performed in realistic neutron fields at the high energy accelerator SPS at CERN (CERF facility) and in Cave A at the heavy ion synchrotron SIS at GSI are presented. The results of these measurements are compared with the expected dose values from the neutron spectra determined for the measurement positions at CERF and in Cave A (FLUKA) and with the dosemeter response derived by the calculated response functions (FLUKA) folded with the neutron spectra. The comparisons show that the additional lead layer in the PE/Pb-sphere improves significantly the response of the dosemeter. The response of the PE/Pb-sphere is 40 to 50 % higher at CERF and Cave A in comparison to the bare PE-sphere. At CERF the dose values of the PE/Pb-sphere is about 25 % lower than the expected dose value, whilst for Cave A, a rather good agreement was found (2 % deviation). (author)

  2. The highs and lows of theoretical interpretation in animal-metacognition research

    Science.gov (United States)

    Smith, J. David; Couchman, Justin J.; Beran, Michael J.

    2012-01-01

    Humans feel uncertain. They know when they do not know. These feelings and the responses to them ground the research literature on metacognition. It is a natural question whether animals share this cognitive capacity, and thus animal metacognition has become an influential research area within comparative psychology. Researchers have explored this question by testing many species using perception and memory paradigms. There is an emerging consensus that animals share functional parallels with humans’ conscious metacognition. Of course, this research area poses difficult issues of scientific inference. How firmly should we hold the line in insisting that animals’ performances are low-level and associative? How high should we set the bar for concluding that animals share metacognitive capacities with humans? This area offers a constructive case study for considering theoretical problems that often confront comparative psychologists. The authors present this case study and address diverse issues of scientific judgement and interpretation within comparative psychology. PMID:22492748

  3. Selection and adaptation in irradiated plant and animal populations: a review

    International Nuclear Information System (INIS)

    Hart, D.R.

    1981-03-01

    Available literature on the effects of ionizing radiation on mutation rates, variability and adaptive responses to selection in exposed plant and animal populations is reviewed. Accumulated variability, and hence potential selection differentials, may be increased by many times due to induced mutation. The radiation dose that maximizes induced mutation varies greatly among species, strains and genetic systems. Induced variability tends to enhance the respose to selection, but this effect may be delayed or prevented by an initial reduction in the heritability of induced variation. Significantly, the detrimental effects of harmful mutations in irradiated populations may exceed the beneficial effects of selection for adaptive characteristics. Selection for radioresistance may occur at lethal or sub-lethal radiation doses but dose relationships are highly variable. (author)

  4. High-dose simultaneously integrated breast boost using intensity-modulated radiotherapy and inverse optimization

    International Nuclear Information System (INIS)

    Hurkmans, Coen W.; Meijer, Gert J.; Vliet-Vroegindeweij, Corine van; Sangen, Maurice J. van der; Cassee, Jorien

    2006-01-01

    Purpose: Recently a Phase III randomized trial has started comparing a boost of 16 Gy as part of whole-breast irradiation to a high boost of 26 Gy in young women. Our main aim was to develop an efficient simultaneously integrated boost (SIB) technique for the high-dose arm of the trial. Methods and Materials: Treatment planning was performed for 5 left-sided and 5 right-sided tumors. A tangential field intensity-modulated radiotherapy technique added to a sequentially planned 3-field boost (SEQ) was compared with a simultaneously planned technique (SIB) using inverse optimization. Normalized total dose (NTD)-corrected dose volume histogram parameters were calculated and compared. Results: The intended NTD was produced by 31 fractions of 1.66 Gy to the whole breast and 2.38 Gy to the boost volume. The average volume of the PTV-breast and PTV-boost receiving more than 95% of the prescribed dose was 97% or more for both techniques. Also, the mean lung dose and mean heart dose did not differ much between the techniques, with on average 3.5 Gy and 2.6 Gy for the SEQ and 3.8 Gy and 2.6 Gy for the SIB, respectively. However, the SIB resulted in a significantly more conformal irradiation of the PTV-boost. The volume of the PTV-breast, excluding the PTV-boost, receiving a dose higher than 95% of the boost dose could be reduced considerably using the SIB as compared with the SEQ from 129 cc (range, 48-262 cc) to 58 cc (range, 30-102 cc). Conclusions: A high-dose simultaneously integrated breast boost technique has been developed. The unwanted excessive dose to the breast was significantly reduced

  5. The influence of dose fractionation and dose rate on normal tissue responses

    International Nuclear Information System (INIS)

    Barendsen, G.W.

    1982-01-01

    An analysis of responses of a variety of normal tissues in animals to fractionated irradiations has been made with the aim of developing a formalism for the prediction of tolerance doses as a function of the dose per fraction and the overall treatment time. An important feature of the formalism is that it is directly based on radiological insights and therefore provides a logical concept to account for the diversity of tissue responses. (Auth.)

  6. SU-E-T-457: Design and Characterization of An Economical 192Ir Hemi-Brain Small Animal Irradiator

    International Nuclear Information System (INIS)

    Grams, M; Wilson, Z; Sio, T; Beltran, C; Tryggestad, E; Gupta, S; Blackwell, C; McCollough, K; Sarkaria, J; Furutani, K

    2014-01-01

    Purpose: To describe the design and dosimetric characterization of a simple and economical small animal irradiator. Methods: A high dose rate 192Ir brachytherapy source from a commercially available afterloader was used with a 1.3 centimeter thick tungsten collimator to provide sharp beam penumbra suitable for hemi-brain irradiation of mice. The unit is equipped with continuous gas anesthesia to allow robust animal immobilization. Dosimetric characterization of the device was performed with Gafchromic film. The penumbra from the small animal irradiator was compared under similar collimating conditions to the penumbra from 6 MV photons, 6 MeV electrons, and 20 MeV electrons from a linear accelerator as well as 300 kVp photons from an orthovoltage unit and Monte Carlo simulated 90 MeV protons. Results: The tungsten collimator provides a sharp penumbra suitable for hemi-brain irradiation, and dose rates on the order of 200 cGy/minute were achieved. The sharpness of the penumbra attainable with this device compares favorably to those measured experimentally for 6 MV photons, and 6 and 20 MeV electron beams from a linear accelerator. Additionally, the penumbra was comparable to those measured for a 300 kVp orthovoltage beam and a Monte Carlo simulated 90 MeV proton beam. Conclusions: The small animal irradiator described here can be built for under $1,000 and used in conjunction with any commercial brachytherapy afterloader to provide a convenient and cost-effective option for small animal irradiation experiments. The unit offers high dose rate delivery and sharp penumbra, which is ideal for hemi-brain irradiation of mice. With slight modifications to the design, irradiation of sites other than the brain could be accomplished easily. Due to its simplicity and low cost, the apparatus described is an attractive alternative for small animal irradiation experiments requiring a sharp penumbra

  7. A control study of TACE using high-dosed and routine-dosed iodized oil as a treatment of large hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Zhou Junmin; Zhan Jincheng; Zhang Zhenming

    2005-01-01

    Objective: To investigate the side effects and curative effect in high-dosed lipiodol-transcatheter arterial chemoembolization as a treatment of large hepatocellular carcinoma. Methods: 79 patients with unresectable hepatocellular carcinoma were treated by TACE, and divided into 2 groups. In group A, 39 patients with the tumor sized 7-18cm in diameter, routine-dosed, 10-20ml lipiodol was given in TACE. 40 patients were enrolled in the high-dosed group B, who were given more than 20ml iodized oil in TACE. Results: The First to third year survival rate of group A was 66.7%, 33.3%, 0% respectively,while in group B it was 75%, 45%, 7.5% respectively. The effective rate was 71.7% in Group A and 87.5% in Group B. There was a significant difference between both groups. There was no significant difference of critical side effects and liver function damage between group A and B. Conclusion: High-dosed lipiodol chemoembolization as a treatment of unresectable hepatocellular carcinoma is superior to the routine TACE, especially when the tumor is large and the liver function reserve is good. (authors)

  8. Treatment planning for a small animal using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chow, James C. L.; Leung, Michael K. K.

    2007-01-01

    The development of a small animal model for radiotherapy research requires a complete setup of customized imaging equipment, irradiators, and planning software that matches the sizes of the subjects. The purpose of this study is to develop and demonstrate the use of a flexible in-house research environment for treatment planning on small animals. The software package, called DOSCTP, provides a user-friendly platform for DICOM computed tomography-based Monte Carlo dose calculation using the EGSnrcMP-based DOSXYZnrc code. Validation of the treatment planning was performed by comparing the dose distributions for simple photon beam geometries calculated through the Pinnacle3 treatment planning system and measurements. A treatment plan for a mouse based on a CT image set by a 360-deg photon arc is demonstrated. It is shown that it is possible to create 3D conformal treatment plans for small animals with consideration of inhomogeneities using small photon beam field sizes in the diameter range of 0.5-5 cm, with conformal dose covering the target volume while sparing the surrounding critical tissue. It is also found that Monte Carlo simulation is suitable to carry out treatment planning dose calculation for small animal anatomy with voxel size about one order of magnitude smaller than that of the human

  9. Monitoring of high-radiation areas for the assessment of operational and body doses

    International Nuclear Information System (INIS)

    Chen, T.J.; Tung, C.J.; Yeh, W.W.; Liao, R.Y.

    2004-01-01

    The International Commission on Radiological Protection (ICRP) recommended a system of dose limits for the protection of ionizing radiation. This system was established based on the effective dose, E, and the equivalent dose to an organ or tissue, H T , to assess stochastic and deterministic effects. In radiation protection monitoring for external radiation, operational doses such as the deep dose equivalent index, H I,d , shallow dose equivalent index, H I,s , ambient dose equivalent [1,4-6], H*, directional dose equivalent, H', individual dose equivalent-penetrating, H p , and individual dose equivalent-superficial, H s , are implemented. These quantities are defined in an International Commission on Radiation Units and Measurements (ICRU) sphere and in an anthropomorphic phantom under simplified irradiation conditions. They are useful when equivalent doses are below the corresponding limits. In the case of equivalent doses far below the limits, the exposure or air kerma is commonly applied. For workers exposed to high levels of radiation, accurate assessments of effective doses and equivalent doses may be needed in order to acquire legal and health information. In the general principles of monitoring for radiation protection of workers, ICRP recommended that: 'A graduated response is advocated for the monitoring of the workplace and for individual monitoring - graduated in the sense that a greater degree of monitoring is deemed to be necessary as doses increase of as unpredictability increases. Gradually more complex or realistic procedures should be adopted as doses become higher. Thus, at low dose equivalents (corresponding say to those within Working Condition B) dosimetric quantities might be used directly to assess exposure, since accuracy is not crucial. At intermediate dose equivalents (corresponding say to Working Condition A and slight overexposures) somewhat greater accuracy is warranted, and the conversion coefficients from dosimetric to radiation

  10. High dose potassium-nitrate chemical dosimeter

    International Nuclear Information System (INIS)

    Dorda de Cancio, E.M.; Munoz, S.S.

    1982-01-01

    This dosimeter is used to control 10 kGY-order doses (1 Mrad). Nitrate suffers a radiolitic reduction phenomena, which is related to the given dose. The method to use potassium nitrate as dosimeter is described, as well as effects of the temperature of irradiation, pH, nitrate concentration and post-irradiation stability. Nitrate powder was irradiated at a Semi-Industrial Plant, at Centro Atomico Ezeiza, and also in a Gammacell-220 irradiator. The dose rates used were 2,60 and 1,80 KGY/hour, and the given doses varied between 1,0 and 150 KGY. The uncertainty was +-3% in all the range. (author) [es

  11. High Throughput Screen for Novel Antimicrobials using a Whole Animal Infection Model

    Science.gov (United States)

    Moy, Terence I.; Conery, Annie L.; Larkins-Ford, Jonah; Wu, Gang; Mazitschek, Ralph; Casadei, Gabriele; Lewis, Kim; Carpenter, Anne E.; Ausubel, Frederick M.

    2009-01-01

    The nematode Caenorhabditis elegans is a unique whole animal model system for identifying small molecules with in vivo anti-infective properties. C. elegans can be infected with a broad range of human pathogens, including Enterococcus faecalis, an important human nosocomial pathogen with a mortality rate of up to 37% that is increasingly acquiring resistance to antibiotics. Here, we describe an automated, high throughput screen of 37,200 compounds and natural product extracts for those that enhance survival of C. elegans infected with E. faecalis. The screen uses a robot to accurately dispense live, infected animals into 384-well plates, and automated microscopy and image analysis to generate quantitative, high content data. We identified 28 compounds and extracts that were not previously reported to have antimicrobial properties, including 6 structural classes that cure infected C. elegans animals but do not affect the growth of the pathogen in vitro, thus acting by a mechanism of action distinct from antibiotics currently in clinical use. Our versatile and robust screening system can be easily adapted for other whole animal assays to probe a broad range of biological processes. PMID:19572548

  12. Developing A Directional High-Dose Rate (d-HDR) Brachytherapy Source

    Science.gov (United States)

    Heredia, Athena Yvonne

    Conventional sources used in brachytherapy provide nearly isotropic or radially symmetric dose distributions. Optimizations of dose distributions have been limited to varied dwell times at specified locations within a given treatment volume, or manipulations in source position for seed implantation techniques. In years past, intensity modulated brachytherapy (IMBT) has been used to reduce the amount of radiation to surrounding sensitive structures in select intracavitary cases by adding space or partial shields. Previous work done by Lin et al., at the University of Wisconsin-Madison, has shown potential improvements in conformality for brachytherapy treatments using a directionally shielded low dose rate (LDR) source for treatments in breast and prostate. Directional brachytherapy sources irradiate approximately half of the radial angles around the source, and adequately shield a quarter of the radial angles on the opposite side, with sharp gradient zones between the treated half and shielded quarter. With internally shielded sources, the radiation can be preferentially emitted in such a way as to reduce toxicities in surrounding critical organs. The objective of this work is to present findings obtained in the development of a new directional high dose rate (d-HDR) source. To this goal, 103Pd (Z = 46) is reintroduced as a potential radionuclide for use in HDR brachytherapy. 103Pd has a low average photon energy (21 keV) and relatively short half -life (17 days), which is why it has historically been used in low dose rate applications and implantation techniques. Pd-103 has a carrier-free specific activity of 75000 Ci/g. Using cyclotron produced 103Pd, near carrier-free specific activities can be achieved, providing suitability for high dose rate applications. The evolution of the d-HDR source using Monte Carlo simulations is presented, along with dosimetric parameters used to fully characterize the source. In addition, a discussion on how to obtain elemental

  13. Escalation to High Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease

    Science.gov (United States)

    Triplett, Brandon M.; Kuttab, Hani I.; Kang, Guolian; Leung, Wing

    2015-01-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those utilized in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial, 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. There was no observed increase in toxicity until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10–100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, while those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (p=0.008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose escalation strategy remains unclear, as outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. PMID:26278046

  14. High-dose supplementation with natural α-tocopherol does neither alter the pharmacodynamics of atorvastatin nor its phase I metabolism in guinea pigs

    International Nuclear Information System (INIS)

    Podszun, Maren C.; Grebenstein, Nadine; Hofmann, Ute; Frank, Jan

    2013-01-01

    It has been hypothesized in the literature that intake of high-dosage vitamin E supplements might alter the expression of cytochrome P 450 enzymes (CYP), particularly CYP3A4, which may lead to adverse nutrient–drug interactions. Because previously published studies reported conflicting findings, we investigated the pharmacodynamics of the lipid-lowering drug atorvastatin (ATV), a CYP3A4 substrate, in response to high-dose α-tocopherol (αT) feeding and determined protein expression and activities of relevant CYP. Groups of ten female Dunkin–Hartley guinea pigs were fed a control (5% fat) or a high-fat control diet (HFC; 21% fat, 0.15% cholesterol) or the HFC diet fortified with αT (250 mg/kg diet), ATV (300 mg/kg diet) or both ATV + αT for 6 weeks. Relative to control, HFC animals had increased serum cholesterol concentrations, which were significantly reduced by ATV. High-dose αT feeding in combination with ATV (ATV + αT), albeit not αT feeding alone (αT), significantly lowered serum cholesterol relative to HFC, but did not alter the cholesterol-lowering activity of the drug compared to the ATV treated guinea pigs. Protein expression of CYP3A4, CYP4F2, CYP20A1 and OATP C was similar in all groups. Accordingly, no differences in plasma concentrations of phase I metabolites of ATV were observed between the ATV and ATV + αT groups. In conclusion, feeding guinea pigs high-doses of αT for 6 weeks did neither alter the hepatic expression of CYP, nor the pharmacodynamics and metabolism of ATV. High-dose αT intake is thus unlikely to change the efficacy of drugs metabolized by CYP enzymes, particularly by CYP3A4. -- Highlights: ► Vitamin E-atorvastatin interactions were studied in hypercholesterolemic guinea pigs. ► High-dose α-tocopherol did not alter the lipid-lowering efficacy of atorvastatin. ► α-Tocopherol did not change the expression of CYP3A4, CYP4F2, CYP20A or OATP C. ► α-Tocopherol did not affect phase I metabolism of atorvastatin.

  15. High-dose supplementation with natural α-tocopherol does neither alter the pharmacodynamics of atorvastatin nor its phase I metabolism in guinea pigs

    Energy Technology Data Exchange (ETDEWEB)

    Podszun, Maren C.; Grebenstein, Nadine [Institute of Biological Chemistry and Nutrition, University of Hohenheim, D-70599 Stuttgart (Germany); Hofmann, Ute [Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology, D-70376 Stuttgart (Germany); Frank, Jan [Institute of Biological Chemistry and Nutrition, University of Hohenheim, D-70599 Stuttgart (Germany); Department of Nutrition and Food Science, University of Bonn, D-53115 Bonn (Germany)

    2013-02-01

    It has been hypothesized in the literature that intake of high-dosage vitamin E supplements might alter the expression of cytochrome P{sub 450} enzymes (CYP), particularly CYP3A4, which may lead to adverse nutrient–drug interactions. Because previously published studies reported conflicting findings, we investigated the pharmacodynamics of the lipid-lowering drug atorvastatin (ATV), a CYP3A4 substrate, in response to high-dose α-tocopherol (αT) feeding and determined protein expression and activities of relevant CYP. Groups of ten female Dunkin–Hartley guinea pigs were fed a control (5% fat) or a high-fat control diet (HFC; 21% fat, 0.15% cholesterol) or the HFC diet fortified with αT (250 mg/kg diet), ATV (300 mg/kg diet) or both ATV + αT for 6 weeks. Relative to control, HFC animals had increased serum cholesterol concentrations, which were significantly reduced by ATV. High-dose αT feeding in combination with ATV (ATV + αT), albeit not αT feeding alone (αT), significantly lowered serum cholesterol relative to HFC, but did not alter the cholesterol-lowering activity of the drug compared to the ATV treated guinea pigs. Protein expression of CYP3A4, CYP4F2, CYP20A1 and OATP C was similar in all groups. Accordingly, no differences in plasma concentrations of phase I metabolites of ATV were observed between the ATV and ATV + αT groups. In conclusion, feeding guinea pigs high-doses of αT for 6 weeks did neither alter the hepatic expression of CYP, nor the pharmacodynamics and metabolism of ATV. High-dose αT intake is thus unlikely to change the efficacy of drugs metabolized by CYP enzymes, particularly by CYP3A4. -- Highlights: ► Vitamin E-atorvastatin interactions were studied in hypercholesterolemic guinea pigs. ► High-dose α-tocopherol did not alter the lipid-lowering efficacy of atorvastatin. ► α-Tocopherol did not change the expression of CYP3A4, CYP4F2, CYP20A or OATP C. ► α-Tocopherol did not affect phase I metabolism of atorvastatin

  16. Safety aspects of preoperative high-dose glucocorticoid in primary total knee replacement

    DEFF Research Database (Denmark)

    Jørgensen, C C; Pitter, F T; Kehlet, H

    2017-01-01

    Background: Preoperative single high-dose glucocorticoid may have early outcome benefits in total hip arthroplasty (THA) and knee arthroplasty (TKA), but long-term safety aspects have not been evaluated. Methods: From October 2013, the departments reporting to the prospective Lundbeck Foundation....... Conclusions: In this detailed prospective cohort study, preoperative high-dose glucocorticoid administration was not associated with LOS >4 days, readmissions or infectious complications in TKA patients without contraindications....

  17. Analysis of renal impairment in MM-003, a phase III study of pomalidomide + low - dose dexamethasone versus high - dose dexamethasone in refractory or relapsed and refractory multiple myeloma

    Science.gov (United States)

    Weisel, Katja C.; Dimopoulos, Meletios A.; Moreau, Philippe; Lacy, Martha Q.; Song, Kevin W.; Delforge, Michel; Karlin, Lionel; Goldschmidt, Hartmut; Banos, Anne; Oriol, Albert; Alegre, Adrian; Chen, Christine; Cavo, Michele; Garderet, Laurent; Ivanova, Valentina; Martinez-Lopez, Joaquin; Knop, Stefan; Yu, Xin; Hong, Kevin; Sternas, Lars; Jacques, Christian; Zaki, Mohamed H.; Miguel, Jesus San

    2016-01-01

    Pomalidomide + low-dose dexamethasone is effective and well tolerated for refractory or relapsed and refractory multiple myeloma after bortezomib and lenalidomide failure. The phase III trial MM-003 compared pomalidomide + low-dose dexamethasone with high-dose dexamethasone. This subanalysis grouped patients by baseline creatinine clearance ≥ 30 − < 60 mL/min (n=93, pomalidomide + low-dose dexamethasone; n=56, high-dose dexamethasone) or ≥ 60 mL/min (n=205, pomalidomide + low-dose dexamethasone; n=93, high-dose dexamethasone). Median progression-free survival was similar for both subgroups and favored pomalidomide + low-dose dexamethasone versus high-dose dexamethasone: 4.0 versus 1.9 months in the group with baseline creatinine clearance ≥ 30 − < 60 mL/min (P<0.001) and 4.0 versus 2.0 months in the group with baseline creatinine clearance ≥ 60 mL/min (P<0.001). Median overall survival for pomalidomide + low-dose dexamethasone versus high-dose dexamethasone was 10.4 versus 4.9 months (P=0.030) and 15.5 versus 9.2 months (P=0.133), respectively. Improved renal function, defined as an increase in creatinine clearance from < 60 to ≥ 60 mL/min, was similar in pomalidomide + low-dose dexamethasone and high-dose dexamethasone patients (42% and 47%, respectively). Improvement in progression-free and overall survival in these patients was comparable with that in patients without renal impairment. There was no increase in discontinuations of therapy, dose modifications, and adverse events in patients with moderate renal impairment. Pomalidomide at a starting dose of 4 mg + low-dose dexamethasone is well tolerated in patients with refractory or relapsed and refractory multiple myeloma, and of comparable efficacy if moderate renal impairment is present. This trial was registered with clinicaltrials.gov identifier 01311687 and EudraCT identifier 2010-019820-30. PMID:27081177

  18. Protection and repair of post-thrombolytic brain tissue with high-dose human albumin and magnesium sulfate: an experimental study

    International Nuclear Information System (INIS)

    Li Yongdong; Zhao Jungong; Li Minghua; You Xiaofang; Chen Yingsheng

    2008-01-01

    Objective: To evaluate the neuroprotective effects of high-dose human albumin and magnesium sulfate combined with recombinant tissue plasminogen activator (rt-PA) thrombolysis in a SD rat model of embolic stroke, with the aim to explore the possibility of extention for thrombolytic window. Methods: A thromboembolic stroke model performed on male SD rats (n=40) was randomly assigned into four groups: group A (n=10): rats received an intravenous infusion of 10 mg/kg rt-PA over a period of one hour at 3 h after onset of MCAO; group B (n=10): rats received an intravenous infusion of 10 mg/kg rt-PA over a period of one hour at 6 h after onset of MCAO; group C(n=10): rats received an intravenous infusion of human albumin (2.5 g/kg) and rt-PA(10 mg/kg) at 3 h and 6 h after onset of MCAO; group D(n=10): rats received same dose human albumin and rt-PA as that in group C, in addition, magnesium salfate (500 mg/ kg) was given intraperitoneally 3 h and 18 h after onset of MCAO. MRI was performed in each animal at preischemia, 24 h, 7 d and 14 d after treatment. After the last MR examination, all animals were killed under anesthesia, pathologic study (including electron microscope, light microscope, immuno-histochemistry) was performed in each animal, and LSCM were performed in two animals of each group. Results: The infarct volumes in four groups at 14 d after thrombolysis reduced 5.07% , 2.58%, 10.18% and 35.40% respectively compared with the infarct volume at 3 h after MCAO, with a predominant reduction in group D (P<0.05); increase of rCBV was confirmed at the marginal area of the cerebral infarction from the onset of stroke to 14 d, with significant increase between group A and C from 1 d to 7 d (P<0.05), while no significant difference was found in group B and C. The longest survival exhibited in group D and the shortest in group B, and no significant difference occurred concerning about survival among the four groups (P=0.763, P=0.636). In addition, LSCM showed a slight

  19. In phantom calibration of a high dose rate remote afterloading device

    International Nuclear Information System (INIS)

    Alfonso, R.; Tolede, P.; Pich, V.

    1995-01-01

    The high dose-rate (HDR) brachytherapy in Cuba is based on soviet made devices type AGAT-V. In order to calibration one of these for clinical use a method based of the different measurement of absorbed dose at the reference point B in a paraffin phantom was developed. The results of the calibration are shown. From these results an analysis was made of the effective doses to prescription point a considering the Lineal-Quadratic model. The clinical results by using the AGAT-V device are displayed in a comparative way

  20. Cooperative binding mitigates the high-dose hook effect.

    Science.gov (United States)

    Roy, Ranjita Dutta; Rosenmund, Christian; Stefan, Melanie I

    2017-08-14

    The high-dose hook effect (also called prozone effect) refers to the observation that if a multivalent protein acts as a linker between two parts of a protein complex, then increasing the amount of linker protein in the mixture does not always increase the amount of fully formed complex. On the contrary, at a high enough concentration range the amount of fully formed complex actually decreases. It has been observed that allosterically regulated proteins seem less susceptible to this effect. The aim of this study was two-fold: First, to investigate the mathematical basis of how allostery mitigates the prozone effect. And second, to explore the consequences of allostery and the high-dose hook effect using the example of calmodulin, a calcium-sensing protein that regulates the switch between long-term potentiation and long-term depression in neurons. We use a combinatorial model of a "perfect linker protein" (with infinite binding affinity) to mathematically describe the hook effect and its behaviour under allosteric conditions. We show that allosteric regulation does indeed mitigate the high-dose hook effect. We then turn to calmodulin as a real-life example of an allosteric protein. Using kinetic simulations, we show that calmodulin is indeed subject to a hook effect. We also show that this effect is stronger in the presence of the allosteric activator Ca 2+ /calmodulin-dependent kinase II (CaMKII), because it reduces the overall cooperativity of the calcium-calmodulin system. It follows that, surprisingly, there are conditions where increased amounts of allosteric activator actually decrease the activity of a protein. We show that cooperative binding can indeed act as a protective mechanism against the hook effect. This will have implications in vivo where the extent of cooperativity of a protein can be modulated, for instance, by allosteric activators or inhibitors. This can result in counterintuitive effects of decreased activity with increased concentrations of

  1. Controversies in external beam and high dose rate brachytherapy of oesophageal cancer

    International Nuclear Information System (INIS)

    Sur, R.K.; Levin, V.C.; Malas, Simon; Donde, Bernard

    1994-01-01

    Various controversies in the treatment of oesophageal carcinoma with external beam radiotherapy and high dose rate intracavitary irradiation have been reviewed. Conflicting results from different parts of the world has made it difficult to optimize the radiation dose that may give the best results. More studies and longer follow-up are needed before a definite conclusion can be made on the optimization of dose. (author). 18 refs., 2 tabs

  2. Comparison of traditional low-dose-rate to optimized and nonoptimized high-dose-rate tandem and ovoid dosimetry

    International Nuclear Information System (INIS)

    Decker, William E.; Erickson, Beth; Albano, Katherine; Gillin, Michael

    2001-01-01

    Purpose: Few dose specification guidelines exist when attempting to perform high-dose-rate (HDR) dosimetry. The purpose of this study was to model low-dose-rate (LDR) dosimetry, using parameters common in HDR dosimetry, to achieve the 'pear-shape' dose distribution achieved with LDR tandem and ovoid applications. Methods and Materials: Radiographs of Fletcher-Suit LDR applicators and Nucletron 'Fletcher-like' HDR applicators were taken with the applicators in an idealized geometry. Traditional Fletcher loadings of 3M Cs-137 sources and the Theratronics Planning System were used for LDR dosimetry. HDR dosimetry was performed using the Nucletron Microselectron HDR UPS V11.22 with an Ir-192 source. Dose optimization points were initially located along a line 2 cm lateral to the tandem, beginning at the tandem tip at 0.5-cm intervals, ending at the sail, and optimized to 100% of the point A dose. A single dose optimization point was also placed laterally from the center of each ovoid equal to the radius of the ovoid (ovoid surface dose). For purposes of comparison, dose was also calculated for points A and B, and a point located 1 cm superior to the tandem tip in the plane of the tandem, (point F). Four- and 6-cm tandem lengths and 2.0-, 2.5-, and 3.0-cm ovoid diameters were used for this study. Based on initial findings, dose optimization schemes were developed to best approximate LDR dosimetry. Finally, radiographs were obtained of HDR applications in two patients. These radiographs were used to compare the optimization schemes with 'nonoptimized' treatment plans. Results: Calculated doses for points A and B were similar for LDR, optimized HDR, and nonoptimized HDR. The optimization scheme that used tapered dose points at the tandem tip and optimized a single ovoid surface point on each ovoid to 170% of point A resulted in a good approximation of LDR dosimetry. Nonoptimized HDR resulted in higher doses at point F, the bladder, and at points lateral to the tandem tip

  3. Animal Fascioliasis: Perspectives from high altitudinal regions.

    Science.gov (United States)

    Lyngdoh, Damanbha; Sharma, Sunil; Roy, Bishnupada; Tandon, Veena

    2016-12-15

    The parasitic flukes of the genus Fasciola (Platyhelminthes: Trematoda: Digenea) cause fascioliasis or liver-rot disease in ruminant livestock in tropical and sub-tropical regions of the world. Classically, two species of Fasciola- F. hepatica and F. gigantica, are universally recognized as taxonomically valid species. Our survey studies on ovid and bovid animals including yak and mithun from high altitudinal mountainous regions in Northeast India revealed the occurrence of Fasciola gigantica and also Fasciola sp.- an intermediate form, at altitudes between 5000 and 14,085 feet above sea level (asl). Two morphotypes- F. hepatica - like and F. gigantica - like, of Fasciola species were reported from the high altitudinal areas of Northeast India; most of these locales constitute new-locality and first records for the occurrence of these liver flukes. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Objective method to report planner-independent skin/rib maximal dose in balloon-based high dose rate (HDR) brachytherapy for breast cancer

    International Nuclear Information System (INIS)

    Kim, Yongbok; Trombetta, Mark G.

    2011-01-01

    Purpose: An objective method was proposed and compared with a manual selection method to determine planner-independent skin and rib maximal dose in balloon-based high dose rate (HDR) brachytherapy planning. Methods: The maximal dose to skin and rib was objectively extracted from a dose volume histogram (DVH) of skin and rib volumes. A virtual skin volume was produced by expanding the skin surface in three dimensions (3D) external to the breast with a certain thickness in the planning computed tomography (CT) images. Therefore, the maximal dose to this volume occurs on the skin surface the same with a conventional manual selection method. The rib was also delineated in the planning CT images and its maximal dose was extracted from its DVH. The absolute (Abdiff=|D max Man -D max DVH |) and relative (Rediff[%]=100x(|D max Man -D max DVH |)/D max DVH ) maximal skin and rib dose differences between the manual selection method (D max Man ) and the objective method (D max DVH ) were measured for 50 balloon-based HDR (25 MammoSite and 25 Contura) patients. Results: The average±standard deviation of maximal dose difference was 1.67%±1.69% of the prescribed dose (PD). No statistical difference was observed between MammoSite and Contura patients for both Abdiff and Rediff[%] values. However, a statistically significant difference (p value max >90%) compared with lower dose range (D max <90%): 2.16%±1.93% vs 1.19%±1.25% with p value of 0.0049. However, the Rediff[%] analysis eliminated the inverse square factor and there was no statistically significant difference (p value=0.8931) between high and low dose ranges. Conclusions: The objective method using volumetric information of skin and rib can determine the planner-independent maximal dose compared with the manual selection method. However, the difference was <2% of PD, on average, if appropriate attention is paid to selecting a manual dose point in 3D planning CT images.

  5. Systemic response of Korean dark-striped field mice, Apodenmus agrarius coreae after high-dose- rate γ-irradiation: Organ weights, hemato-chemistry, apoptosis of splenocytes and sperm

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kwang Hee; Choi, Hoon; Joo, Hyun Jin; Kim, Hee Sun [Radiation Health Research Institute, KHNP, Gyeongju (Korea, Republic of); Keum, Dong Kwon [Nuclear Environment Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-11-15

    Since the territory of the radio-contaminated area is in homeogenous in radiation level and spectrum, investigation of the genetical mutation process in the natural animal populations inhabiting the radioontaminated areas will be provide a realistic picture of genetic effects for radiation exposure. However, little is known about the basic data such as systemic responses after ionizing radiation exposures in wild small rodents. Taking into account different radio-sensitivity of dark-striped field mice (A. a. coreae, THOMAS), the objective of the study is focus on investigate the level of systemic responses, included organ weights, hemato-chemistry and apoptosis in splenocytes and sperm of caudal epididymis after high-dose-rate irradiation especially as a potential biological dosimeter in radio-ecology. Figure 1 summarizes the results of the apoptotic events in spleen (data not shown at here) and in sperm of caudal epididymis at 24hrs after a single high-dose-rate γ-irradiation. The results of apoptosis in spleen and sperm caused by exposure to different doses of γ-irradiation are displayed. The data show that the field striped mice after irradiated with more than high dose of 0.5 Gy induces an significantly increased apoptosis. Results also shown that for exposure to 0.5 Gy, the apoptosis of both organs ware decreased compared to those of other γ-irradiated mice.

  6. Clinical application of a OneDose MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast.

    Science.gov (United States)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.

  7. Extra-high doses detected in the enamel of human teeth in the Techa riverside region

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A., E-mail: ElenaA.Shishkina@gmail.com [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Degteva, M.O.; Tolstykh, E.I.; Volchkova, A. [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Ivanov, D.V. [Institute of Metal Physics, Russian Academy of Sciences, 18 S. Kovalevsky Str, 620041 Yekaterinburg (Russian Federation); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, D-85764 Neuherberg (Germany); Della Monaca, S. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Regina Elena, 00144 Rome (Italy); Fattibene, P. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Nazionale di Fisica Nucleare, 00161 Rome (Italy)

    2011-09-15

    During the long-term study of tooth enamel by EPR dosimetry for population exposed to radiation due to contamination of the Techa River, it was found out that for some of the tooth donors the dose accumulated in tooth enamel could be as high as several tens of Gy. Such doses were absorbed only in tooth enamel and they should not be associated with exposures to other organs or the whole body. The nature of such doses was discussed in a number of previous papers where it was shown that the source of such doses is {sup 90}Sr incorporated in the calcified dental tissues. However, among specialists in radiation dosimetry who were not involved in the biokinetic studies, the nature and dosimetric significance of extra-high doses in tooth enamel are still raising questions. The aim of the current paper is to summarize the accumulated information on extra-high doses in the teeth of the Techa riverside residents, describe the dose levels observed, explain the nature of extra-high doses in the enamel and discuss their informative value. The paper includes an overview of already published findings and an analysis of information collected in the data bank of the Urals Research Center for Radiation Medicine (URCRM), Chelyabinsk, Russia, which has not been published before.

  8. Early Angiographic Resolution of Cerebral Vasospasm with High Dose Intravenous Milrinone Therapy

    Directory of Open Access Journals (Sweden)

    F. A. Zeiler

    2015-01-01

    Full Text Available Background. Treatment of symptomatic delayed cerebral ischemia (DCI after subarachnoid hemorrhage (SAH is difficult. Recent studies suggest intravenous (IV high dose milrinone as a potential therapy. The timing to angiographic response with this is unclear. Methods. We reviewed the chart of one patient admitted for SAH who developed symptomatic DCI and was treated with high dose IV milrinone. Results. A 66-year-old female was admitted with a Hunt and Hess clinical grade 4, World Federation of Neurological Surgeons (WFNS clinical grade 4, and SAH secondary to a left anterior choroidal artery aneurysm which was clipped. After bleed day 6, the patient developed symptomatic DCI. We planned for angioplasty of the proximal segments. We administered high dose IV milrinone bolus followed by continuous infusion which led to clinical improvement prior to angiography. The angiogram performed 1.5 hours after milrinone administration displayed resolution of the CT angiogram and MRI based cerebral vasospasm such that further intra-arterial therapy was aborted. She completed 6 days of continuous IV milrinone therapy, was transferred to the ward, and subsequently rehabilitated. Conclusions. High dose IV milrinone therapy for symptomatic DCI after SAH can lead to rapid neurological improvement with dramatic early angiographic improvement of cerebral vasospasm.

  9. Electiveness of photorepair, influence of dark-repair on shape of dose-response curves, and high-dose decline, in UV-induced colour mutations of Serratia

    International Nuclear Information System (INIS)

    Kaplan, R.W.

    1978-01-01

    Strain CV of Serratia marcescens mutates by UV with high frequency to 3 groups of mutants (w, h, s) differing in colour from the red wild-type. The mutational dose-response curve has a curvature corresponding to about 3 hits. It reaches a peak and declines at high doses. Inactivation curves have a broad shoulder and mostly, but not always, a break to a lesser slope at UV doses near the peak of mutations. Photo reactivation (PR) gives a dose reduction of about 2 for both inactivation and mutation including the break and peak. The dose curve with PR for w-mutations shows 1 hit-, the other types 2-hit curvature leading to a change of mutation spectrum with dose due to PR. The UV-sensitive mutant uvs21 of CV has a survival curve with a small shoulder and a long upward concavity without a break, and the mutation curve is of the one-hit type without a peak and decline. PR gives a dose reduction of 12 for inactivation and of 7.5 for mutation. The 3-hit mutation curve of CV is interpreted by assuming that 2 further hits are required to protect the 1-hit pre-mutations from being abolished by the repair lacking in uvs21. UV induction of SOS repair cannot be responsible for the 3-hit curvature because UVR of phages and induction of prophage are already saturated at rather low doses. As high-dose decline is not observed in uvs21, possibly the non-mutagenic repair lacking from uvs21 interferes with the mutation finishing processes at high doses in the repair-proficient strain CV. However, UV induction of this interference cannot be a one-hit process but requires a very large number of hits. (Auth.)

  10. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige [Kinki Univ., Atomic Energy Research Institute, Osaka (Japan); Tatsumi, Kusuo [Kinki Univ., Life Science Research Institute, Osaka (Japan); Nakai, Sayaka; Sugahara, Tsutomu [Health Research Foundation, Kyoto (Japan); Yuan Yongling [Labor Hygiene Institute of Hunan Prov. (China); Wei Luxin [Laboratory of Industorial Hygiene, Ministry of Health (China)

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: (1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. (2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  11. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    International Nuclear Information System (INIS)

    Koga, Taeko; Morishima, Hiroshige; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: 1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. 2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  12. Highly dynamic animal contact network and implications on disease transmission

    OpenAIRE

    Shi Chen; Brad J. White; Michael W. Sanderson; David E. Amrine; Amiyaal Ilany; Cristina Lanzas

    2014-01-01

    Contact patterns among hosts are considered as one of the most critical factors contributing to unequal pathogen transmission. Consequently, networks have been widely applied in infectious disease modeling. However most studies assume static network structure due to lack of accurate observation and appropriate analytic tools. In this study we used high temporal and spatial resolution animal position data to construct a high-resolution contact network relevant to infectious disease transmissio...

  13. Cancer and low dose responses in vivo: implications for radiation protection

    International Nuclear Information System (INIS)

    Mitchel, R.E.J.

    2006-01-01

    Full text: Radiation protection practices assume that cancer risk is linearly proportional to total dose, without a threshold, both for people with normal cancer risk and for people who may be genetically cancer prone. Mice heterozygous for the Tp 53 gene are cancer prone, and their increased risk from high doses was not different from Tp 53 normal mice. However, in either Tp 53 normal or heterozygous mice, a single low dose of low LET radiation given at low dose rate protected against both spontaneous and radiation-induced cancer by increasing tumor latency. Increased tumor latency without a cancer frequency change implies that low doses in vivo primarily slow the process of genomic instability, consistent with the elevated capacity for correct DSB rejoining seen in low dose exposed cells. The in vivo animal data indicates that, for low doses and low dose rates in both normal and cancer prone adult mice, risk does not increase linearly with dose, and dose thresholds for increased risk exist. Below those dose thresholds (which are influenced by Tp 53 function) overall risk is reduced below that of unexposed control mice, indicating that Dose Rate Effectiveness Factors (DREF) may approach infinity, rather than the current assumption of 2. However, as dose decreases, different tissues appear to have different thresholds at which detriment turns to protection, indicating that individual tissue weighting factors (Wt) are also not constant, but vary from positive values to zero with decreasing dose. Measurements of Relative Biological Effect between high and low LET radiations are used to establish radiation weighting factors (Wr) used in radiation protection, and these are also assumed to be constant with dose. However, since the risk from an exposure to low LET radiation is not constant with dose, it would seem unlikely that radiation-weighting factors for high LET radiation are actually constant at low dose and dose rate

  14. Tolerance of the Brachial Plexus to High-Dose Reirradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Allen M., E-mail: achen5@kumc.edu; Yoshizaki, Taeko; Velez, Maria A.; Mikaeilian, Argin G.; Hsu, Sophia; Cao, Minsong

    2017-05-01

    Purpose: To study the tolerance of the brachial plexus to high doses of radiation exceeding historically accepted limits by analyzing human subjects treated with reirradiation for recurrent tumors of the head and neck. Methods and Materials: Data from 43 patients who were confirmed to have received overlapping dose to the brachial plexus after review of radiation treatment plans from the initial and reirradiation courses were used to model the tolerance of this normal tissue structure. A standardized instrument for symptoms of neuropathy believed to be related to brachial plexus injury was utilized to screen for toxicity. Cumulative dose was calculated by fusing the initial dose distributions onto the reirradiation plan, thereby creating a composite plan via deformable image registration. The median elapsed time from the initial course of radiation therapy to reirradiation was 24 months (range, 3-144 months). Results: The dominant complaints among patients with symptoms were ipsilateral pain (54%), numbness/tingling (31%), and motor weakness and/or difficulty with manual dexterity (15%). The cumulative maximum dose (Dmax) received by the brachial plexus ranged from 60.5 Gy to 150.1 Gy (median, 95.0 Gy). The cumulative mean (Dmean) dose ranged from 20.2 Gy to 111.5 Gy (median, 63.8 Gy). The 1-year freedom from brachial plexus–related neuropathy was 67% and 86% for subjects with a cumulative Dmax greater than and less than 95.0 Gy, respectively (P=.05). The 1-year complication-free rate was 66% and 87%, for those reirradiated within and after 2 years from the initial course, respectively (P=.06). Conclusion: The development of brachial plexus–related symptoms was less than expected owing to repair kinetics and to the relatively short survival of the subject population. Time-dose factors were demonstrated to be predictive of complications.

  15. The effects of a high-animal- and a high-vegetable-protein diet on mineral balance and bowel function of young men

    OpenAIRE

    Dokkum, W. van; Wesstra, A.; Luyken, R.; Hermus, R.J.J.

    1986-01-01

    Twelve young men were given for periods of 20 d, each of three mixed diets, namely a low-protein (LP) diet (9% total energy as protein, 67% of animal origin), a high-animal-protein (HA) diet (16% total energy as protein, 67% of animal origin) and a high-vegetable-protein (HV) diet (16% total energy as protein, 67% of vegetable origin). Retention of calcium, magnesium, iron, zinc and copper as well as various bowel function indices were investigated during each dietary period. Neither the HA d...

  16. Schistosoma mansoni: is acquired immunity induced by highly x-irradiated cercariae dependent on the size of the challenging dose

    International Nuclear Information System (INIS)

    Hsue, S.Y.; Hsue, H.F.; Osborne, J.W.; Johnson, S.C.

    1982-01-01

    A high degree of immunity, as shown by a 91% reduction of the number of worms recovered was found in five groups of mice that were immunized five times with highly X-irradiated cercariae and then challenged with 10, 20, 50, 100, or 500 normal Schistosoma mansoni cercariae. The results indicated that there were no significant differences in worm reduction in immunized mice challenged with different numbers of cercariae; consequently the immunity induced by this immunization method did not appear to be challenge-dose-dependent. However, the results also showed that when immunized mice were challenged with 500, 100, 50, 20, and 10 cercariae, 0, 13, 26, 56, and 68%, respectively, of the experimental animals were free of worms. Thus, the percentage of worm-negative cases increased as the number of challenge cercariae decreased. When viewed in this manner, the acquired immunity may be considered challenge-dose-dependent as well. If this method of vaccination is used for schistosomiasis control, we may anticipate that in both hypo- and hyperendemic areas, the intensity of infection and the severity of the disease will be reduced owing to a reduction in worms burdens, and in hypoendemic areas, there will be a number of worm-free cases

  17. Independent technique of verifying high-dose rate (HDR) brachytherapy treatment plans

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Korb, Leroy J.; Darnell, Brenda; Krishna, K. V.; Ulewicz, Dennis

    1998-01-01

    Purpose: An independent technique for verifying high-dose rate (HDR) brachytherapy treatment plans has been formulated and validated clinically. Methods and Materials: In HDR brachytherapy, dwell times at respective dwell positions are computed, using an optimization algorithm in a HDR treatment-planning system to deliver a specified dose to many target points simultaneously. Because of the variability of dwell times, concerns have been expressed regarding the ability of the algorithm to compute the correct dose. To address this concern, a commercially available low-dose rate (LDR) algorithm was used to compute the doses at defined distances, based on the dwell times obtained from the HDR treatment plans. The percent deviation between doses computed using the HDR and LDR algorithms were reviewed for HDR procedures performed over the last year. Results: In this retrospective study, the difference between computed doses using the HDR and LDR algorithms was found to be within 5% for about 80% of the HDR procedures. All of the reviewed procedures have dose differences of less than 10%. Conclusion: An independent technique for verifying HDR brachytherapy treatment plans has been validated based on clinical data. Provided both systems are available, this technique is universal in its applications and not limited to either a particular implant applicator, implant site, or implant type

  18. High-dose steroid therapy for idiopathic optic perineuritis: a case series

    Directory of Open Access Journals (Sweden)

    Mimura Tatsuya

    2010-12-01

    Full Text Available Abstract Introduction It has been reported that the prognosis of optic perineuritis may be poor when initiation of treatment is delayed. Here we report the successful treatment of three patients with idiopathic optic perineuritis, including two in whom initiation of therapy was delayed. Case presentation Three Japanese patients (two women aged 73 and 66 years, and one man aged 27 years presented with loss of vision (for five months, several months, and two months respectively and pain on eye movement in the third case only, and were diagnosed as having idiopathic optic perineuritis. Fat-suppressed T2-weighted magnetic resonance images showed high signal intensity areas around the affected optic nerves, suggesting the presence of optic perineuritis. Two patients received steroid pulse therapy and the third was given high-dose steroid therapy. The visual acuity improved in all three cases. Conclusion High-dose steroid therapy may be effective for idiopathic perineuritis in patients without optic nerve atrophy, even if initial treatment (including moderate-dose steroids has failed.

  19. Animal Rights Groups Target High School Dissection.

    Science.gov (United States)

    Trotter, Andrew

    1992-01-01

    Two groups leading the charge against dissection are People for the Ethical Treatment of Animals (PETA) and the Student Action Corps for Animals (SACA). Protests by student and community members remain the movement's strongest weapon. (MLF)

  20. Dramatic response to high-dose icotinib in a lung adenocarcinoma patient after erlotinib failure.

    Science.gov (United States)

    Guan, Yin; Zhao, Hong; Meng, Jing; Yan, Xiang; Jiao, ShunChang

    2014-02-01

    Epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) retreatment is rarely administered for non-small cell lung cancer (NSCLC) patients who did not respond to previous TKI treatment. A high dose of TKI may overcome resistance to the standard dose of TKI and have different effectiveness toward cancer compared with the standard dose of TKI. This manuscript describes a dramatic and durable response to high-dose icotinib in a NSCLC patient who did not respond to a previous standard dose of erlotinib. The treatment extended the life of the patient for one additional year. A higher dose of icotinib deserves further study not only for patients whose therapy failed with the standard dose of TKI but also for newly diagnosed NSCLC patients with a sensitive mutation. Serial mutation testing during disease development is necessary for analysis and evaluation of EGFR TKI treatment. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Development of dose delivery verification by PET imaging of photonuclear reactions following high energy photon therapy

    International Nuclear Information System (INIS)

    Janek, S; Svensson, R; Jonsson, C; Brahme, A

    2006-01-01

    A method for dose delivery monitoring after high energy photon therapy has been investigated based on positron emission tomography (PET). The technique is based on the activation of body tissues by high energy bremsstrahlung beams, preferably with energies well above 20 MeV, resulting primarily in 11 C and 15 O but also 13 N, all positron-emitting radionuclides produced by photoneutron reactions in the nuclei of 12 C, 16 O and 14 N. A PMMA phantom and animal tissue, a frozen hind leg of a pig, were irradiated to 10 Gy and the induced positron activity distributions were measured off-line in a PET camera a couple of minutes after irradiation. The accelerator used was a Racetrack Microtron at the Karolinska University Hospital using 50 MV scanned photon beams. From photonuclear cross-section data integrated over the 50 MV photon fluence spectrum the predicted PET signal was calculated and compared with experimental measurements. Since measured PET images change with time post irradiation, as a result of the different decay times of the radionuclides, the signals from activated 12 C, 16 O and 14 N within the irradiated volume could be separated from each other. Most information is obtained from the carbon and oxygen radionuclides which are the most abundant elements in soft tissue. The predicted and measured overall positron activities are almost equal (-3%) while the predicted activity originating from nitrogen is overestimated by almost a factor of two, possibly due to experimental noise. Based on the results obtained in this first feasibility study the great value of a combined radiotherapy-PET-CT unit is indicated in order to fully exploit the high activity signal from oxygen immediately after treatment and to avoid patient repositioning. With an RT-PET-CT unit a high signal could be collected even at a dose level of 2 Gy and the acquisition time for the PET could be reduced considerably. Real patient dose delivery verification by means of PET imaging seems to be

  2. Escalation to High-Dose Defibrotide in Patients with Hepatic Veno-Occlusive Disease.

    Science.gov (United States)

    Triplett, Brandon M; Kuttab, Hani I; Kang, Guolian; Leung, Wing

    2015-12-01

    Hepatic veno-occlusive disease (VOD) is a serious complication of high-dose chemotherapy regimens, such as those used in hematopoietic cell transplantation recipients. Defibrotide is considered a safe and effective treatment when dosed at 25 mg/kg/day. However, patients who develop VOD still have increased mortality despite the use of defibrotide. Data are limited on the use of doses above 60 mg/kg/day for persistent VOD. In this prospective clinical trial 34 patients received escalating doses of defibrotide. For patients with persistent VOD despite doses of 60 mg/kg/day, doses were increased to a maximum of 110 mg/kg/day. Increased toxicity was not observed until doses rose beyond 100 mg/kg/day. Patients receiving doses between 10 and 100 mg/kg/day experienced an average of 3 bleeding episodes per 100 days of treatment, whereas those receiving doses >100 mg/kg/day experienced 13.2 bleeding episodes per 100 days (P = .008). Moreover, dose reductions due to toxicity were needed at doses of 110 mg/kg/day more often than at lower doses. Defibrotide may be safely escalated to doses well above the current standard without an increase in bleeding risk. However, the efficacy of this dose-escalation strategy remains unclear, because outcomes were similar to published cohorts of patients receiving standard doses of defibrotide for VOD. Copyright © 2015 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Treating tuberculosis with high doses of anti-TB drugs: mechanisms and outcomes.

    Science.gov (United States)

    Xu, Yuhui; Wu, Jianan; Liao, Sha; Sun, Zhaogang

    2017-10-03

    Tuberculosis (TB) is considered as one of the most serious threats to public health in many parts of the world. The threat is even more severe in the developing countries where there is a lack of advanced medical amenities and contemporary anti-TB drugs. In such situations, dosage optimization of existing medication regimens seems to be the only viable option. Therapeutic drug monitoring study results suggest that high-dose treatment regimens can compensate the low serum concentration of anti-TB drugs and shorten the therapy duration. The article presents a critical review on the possible changes that occur in the host and the pathogen upon the administration of standard and high-dose regimens. Some of the most common factors that are responsible for low anti-TB drug concentrations in the serum are differences in hosts' body weight, metabolic processing of the drug, malabsorption and/or drug-drug interaction. Furthermore, failure to reach the cavitary pulmonary and extrapulmonary tissues also contributes to the therapeutic inefficiency of the drugs. In such conditions, administration of higher doses can help in compensating the pathogenic outcomes of enhancement of the pathogen's physical barriers, efflux pumps and genetic mutations. The present article also presents a summary of the recorded treatment outcomes of clinical trials that were conducted to test the efficacy of administration of high dose of anti-tuberculosis drugs. This review will help physicians across the globe to understand the underlying pathophysiological changes (including side effects) that dictate the clinical outcomes in patients administered with standard and/or high dose anti-TB drugs.

  4. Electromagnetic Processing as a Way of Increasing Microbiological Safety of Animal Waste

    Science.gov (United States)

    Soboleva, O. M.; Kolosova, M. M.; Filipovich, L. A.; Aksenov, V. A.

    2017-05-01

    The article shows the possibility of using the electromagnetic field of ultrahigh frequency (EMF UHF) for drying and disinfecting of such animal waste as pig manure and poultry droppings. The studied modes included the following options: processing exposure of 60, 90, 120 sec, the capacity of 60 kW, the frequency of 915 MHz. The method of UHF processing of manure and poultry droppings is environmentally safe and effective in neutralizing the pathogenic microflora, as well as larvae and eggs of worms. The following processing mode of animal waste in the electromagnetic field of ultrahigh frequency was recognized as optimal: exposure of 90 seconds, the capacity of 60 kW, the frequency of 915 MHz. This option leads to the complete destruction of pathogenic and conditionally pathogenic microorganisms, as well as the eggs and larvae of worms. As a result of this processing, a high level of microbiological safety of pig manure and poultry droppings is achieved that allows using them as organic fertilizers. The peculiarities of some species of pathogenic fungi developing on the surface of the wheat grain are shown. Pre-processed animal waste (pig manure and and poultry droppings) were applied in experimental variants. Used organic fertilizers underwent electromagnetic processing of ultra-high frequency. The qualitative composition of the microflora on the surface of the grain depends on the type of animal waste (manure or droppings) and used dose. The safest part of the microflora of grain was marked with the application of the UHF-processed pig manure and poultry droppings in doses of 10 t/ha.

  5. Dose accumulation of multiple high dose rate prostate brachytherapy treatments in two commercially available image registration systems.

    Science.gov (United States)

    Poder, Joel; Yuen, Johnson; Howie, Andrew; Bece, Andrej; Bucci, Joseph

    2017-11-01

    The purpose of this study was to assess whether deformable image registration (DIR) is required for dose accumulation of multiple high dose rate prostate brachytherapy (HDRPBT) plans treated with the same catheter pattern on two different CT datasets. DIR was applied to 20 HDRPBT patients' planning CT images who received two treatment fractions on sequential days, on two different CT datasets, with the same implant. Quality of DIR in Velocity and MIM image registration systems was assessed by calculating the Dice Similarity Coefficient (DSC) and mean distance to agreement (MDA) for the prostate, urethra and rectum contours. Accumulated doses from each system were then calculated using the same DIR technique and dose volume histogram (DVH) parameters compared to manual addition with no DIR. The average DSC was found to be 0.83 (Velocity) and 0.84 (MIM), 0.80 (Velocity) and 0.80 (MIM), 0.80 (Velocity) and 0.81 (MIM), for the prostate, rectum and urethra contours, respectively. The average difference in calculated DVH parameters between the two systems using dose accumulation was less than 1%, and there was no statistically significant difference found between deformably accumulated doses in the two systems versus manual DVH addition with no DIR. Contour propagation using DIR in velocity and MIM was shown to be at least equivalent to inter-observer contouring variability on CT. The results also indicate that dose accumulation through manual addition of DVH parameters may be sufficient for HDRPBT treatments treated with the same catheter pattern on two different CT datasets. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  6. A 14-day repeated-dose oral toxicological evaluation of an isothiocyanate-enriched hydro-alcoholic extract from Moringa oleifera Lam. seeds in rats.

    Science.gov (United States)

    Kim, Youjin; Jaja-Chimedza, Asha; Merrill, Daniel; Mendes, Odete; Raskin, Ilya

    2018-01-01

    A 14-d short-term oral toxicity study in rats evaluated the safety of moringa isothiocyanate-1 (MIC-1)-enriched hydro-alcoholic moringa seeds extract (MSE). Rats (5 males/5 females per group) were gavaged daily for 14 d with the vehicle control or MSE, at 78 (low), 257 (mid-low), 772 (mid-high), or 2571 (high) mg/kg bw/d, standardized to MIC-1 (30, 100, 300, or 1000 mg/kg bw/d, respectively). Toxicological endpoints included body weight and weight gain, food consumption and feed efficiency, clinical observations, hematology, gross necropsy and histopathology, and relative organ weights. Mortality was only observed in the high dose group animals, both male and female, representing decreases in body weight/weight gain and food consumption/feed efficiency. Irregular respiratory patterns and piloerection were major clinical observations found primarily in the mid-high and high dose group animals. In the high dose group, gastrointestinal distention and stomach discoloration were observed in non-surviving males and females, and degeneration and necrosis of the testicular germinal cells and epididymal cells were also observed in a non-surviving male. Increased liver weights were found in females in the mid-high and high dose groups. Animals in the low and mid-low groups did not exhibit adverse effects of MSE (100 mg/kg bw/d MIC-1). A no observed adverse effect level (NOAEL) of the standardized MSE was determined as 257 mg/kg bw/d providing 100 mg/kg bw/d MIC-1.

  7. Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi

    2016-11-08

    Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.

  8. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  9. High-dose calcium stimulation test in a case of insulinoma masquerading as hysteria.

    Science.gov (United States)

    Nakamura, Yoshio; Doi, Ryuichiro; Kohno, Yasuhiro; Shimono, Dai; Kuwamura, Naomitsu; Inoue, Koichi; Koshiyama, Hiroyuki; Imamura, Masayuki

    2002-11-01

    It is reported that some cases with insulinoma present with neuropsychiatric symptoms and are often misdiagnosed as psychosis. Here we report a case of insulinoma masquerading as hysteria, whose final diagnosis could be made using high-dose calcium stimulation test. A 28-yr-old woman was referred presenting with substupor, mutism, mannerism, restlessness, and incoherence. Laboratory examinations revealed hypoglycemia (33 mg/dL) and detectable insulin levels (9.7 microU/mL), suggesting the diagnosis of insulinoma. However, neither imaging studies nor selective arterial calcium injection (SACI) test with a conventional dose of calcium (0.025 mEq/kg) indicated the tumor. High-dose calcium injection (0.05 mEq/kg) evoked insulin secretion when injected into superior mesenteric artery. A solitary tumor in the head of the pancreas was resected, and her plasma glucose returned to normal. Postoperatively, iv injection of secretin resulted in a normal response of insulin, which was not found preoperatively. This case suggests the usefulness of the SACI test with high-dose of calcium in the case of insulinoma when the standard dose fails to detect such a tumor.

  10. Low dose X –ray effects on catalase activity in animal tissue

    International Nuclear Information System (INIS)

    Focea, R; Nadejde, C; Creanga, D; Luchian, T

    2012-01-01

    This study was intended to investigate the effect of low-dose X ray-irradiation upon the activity of catalase (CAT) in freshly excised chicken tissues (liver, kidney, brain, muscle). The tissue samples were irradiated with 0.5Gy and 2Gy respectively, in a 6 MV photon beam produced by a clinical linear accelerator (VARIAN CLINAC 2100SC). The dose rate was of 260.88cGy/min. at 100 cm source to sample distance. The catalase level was assayed spectrophotometrically, based on reaction kinetics, using a catalase UV assay kit (SIGMA). Catalase increased activity in various tissue samples exposed to the studied X ray doses (for example with 24 % in the liver cells, p<0.05) suggested the stimulation of the antioxidant enzyme biosynthesis within several hours after exposure at doses of 0.5 Gy and 2 Gy; the putative enzyme inactivation could also occur (due to the injuries on the hydrogen bonds that ensure the specificity of CAT active site) but the resulted balance of the two concurrent processes indicates the cell ability of decomposing the hydrogen peroxide-with benefits for the cell physiology restoration for the chosen low dose radiation.

  11. Histology and Gadolinium Distribution in the Rodent Brain After the Administration of Cumulative High Doses of Linear and Macrocyclic Gadolinium-Based Contrast Agents

    Science.gov (United States)

    Lohrke, Jessica; Frisk, Anna-Lena; Frenzel, Thomas; Schöckel, Laura; Rosenbruch, Martin; Jost, Gregor; Lenhard, Diana Constanze; Sieber, Martin A.; Nischwitz, Volker; Küppers, Astrid; Pietsch, Hubertus

    2017-01-01

    Objectives Retrospective studies in patients with primary brain tumors or other central nervous system pathologies as well as postmortem studies have suggested that gadolinium (Gd) deposition occurs in the dentate nucleus (DN) and globus pallidus (GP) after multiple administrations of primarily linear Gd-based contrast agents (GBCAs). However, this deposition has not been associated with any adverse effects or histopathological alterations. The aim of this preclinical study was to systematically examine differences between linear and macrocyclic GBCAs in their potential to induce changes in brain and skin histology including Gd distribution in high spatial resolution. Materials and Methods Fifty male Wistar-Han rats were randomly allocated into control (saline, n = 10 rats) and 4 GBCA groups (linear GBCAs: gadodiamide and gadopentetate dimeglumine, macrocyclic GBCAs: gadobutrol and gadoteridol; n = 10 rats per group). The animals received 20 daily intravenous injections at a dose of 2.5 mmol Gd/kg body weight. Eight weeks after the last GBCA administration, the animals were killed, and the brain and skin samples were histopathologically assessed (hematoxylin and eosin; cresyl violet [Nissl]) and by immunohistochemistry. The Gd concentration in the skin, bone, brain, and skeletal muscle samples were analyzed using inductively coupled plasma mass spectroscopy (ICP-MS, n = 4). The spatial Gd distribution in the brain and skin samples was analyzed in cryosections using laser ablation coupled with ICP-MS (LA-ICP-MS, n = 3). For the ultra-high resolution of Gd distribution, brain sections of rats injected with gadodiamide or saline (n = 1) were assessed by scanning electron microscopy coupled to energy dispersive x-ray spectroscopy and transmission electron microscopy, respectively. Results No histological changes were observed in the brain. In contrast, 4 of 10 animals in the gadodiamide group but none of the animals in other groups showed macroscopic and histological

  12. Dose Assessment Model for Chronic Atmospheric Releases of Tritium

    International Nuclear Information System (INIS)

    Shen Huifang; Yao Rentai

    2010-01-01

    An improved dose assessment model for chronic atmospheric releases of tritium was proposed. The proposed model explicitly considered two chemical forms of tritium.It was based on conservative assumption of transfer of tritiated water (HTO) from air to concentration of HTO and organic beam tritium (OBT) in vegetable and animal products.The concentration of tritium in plant products was calculated based on considering dividedly leafy plant and not leafy plant, meanwhile the concentration contribution of tritium in the different plants from the tritium in soil was taken into account.Calculating the concentration of HTO in animal products, average water fraction of animal products and the average weighted tritium concentration of ingested water based on the fraction of water supplied by each source were considered,including skin absorption, inhalation, drinking water and food.Calculating the annual doses, the ingestion doses were considered, at the same time the contribution of inhalation and skin absorption to the dose was considered. Concentrations in foodstuffs and dose of annual adult calculated with the specific activity model, NEWTRI model and the model proposed by the paper were compared. The results indicate that the model proposed by the paper can predict accurately tritium doses through the food chain from chronic atmospheric releases. (authors)

  13. Photon iso-effective dose for cancer treatment with mixed field radiation based on dose-response assessment from human and an animal model: clinical application to boron neutron capture therapy for head and neck cancer

    Science.gov (United States)

    González, S. J.; Pozzi, E. C. C.; Monti Hughes, A.; Provenzano, L.; Koivunoro, H.; Carando, D. G.; Thorp, S. I.; Casal, M. R.; Bortolussi, S.; Trivillin, V. A.; Garabalino, M. A.; Curotto, P.; Heber, E. M.; Santa Cruz, G. A.; Kankaanranta, L.; Joensuu, H.; Schwint, A. E.

    2017-10-01

    Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson’s correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r  >  0.87 and p-values  >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed

  14. Photon iso-effective dose for cancer treatment with mixed field radiation based on dose-response assessment from human and an animal model: clinical application to boron neutron capture therapy for head and neck cancer.

    Science.gov (United States)

    González, S J; Pozzi, E C C; Monti Hughes, A; Provenzano, L; Koivunoro, H; Carando, D G; Thorp, S I; Casal, M R; Bortolussi, S; Trivillin, V A; Garabalino, M A; Curotto, P; Heber, E M; Santa Cruz, G A; Kankaanranta, L; Joensuu, H; Schwint, A E

    2017-10-03

    Boron neutron capture therapy (BNCT) is a treatment modality that combines different radiation qualities. Since the severity of biological damage following irradiation depends on the radiation type, a quantity different from absorbed dose is required to explain the effects observed in the clinical BNCT in terms of outcome compared with conventional photon radiation therapy. A new approach for calculating photon iso-effective doses in BNCT was introduced previously. The present work extends this model to include information from dose-response assessments in animal models and humans. Parameters of the model were determined for tumour and precancerous tissue using dose-response curves obtained from BNCT and photon studies performed in the hamster cheek pouch in vivo models of oral cancer and/or pre-cancer, and from head and neck cancer radiotherapy data with photons. To this end, suitable expressions of the dose-limiting Normal Tissue Complication and Tumour Control Probabilities for the reference radiation and for the mixed field BNCT radiation were developed. Pearson's correlation coefficients and p-values showed that TCP and NTCP models agreed with experimental data (with r  >  0.87 and p-values  >0.57). The photon iso-effective dose model was applied retrospectively to evaluate the dosimetry in tumours and mucosa for head and neck cancer patients treated with BNCT in Finland. Photon iso-effective doses in tumour were lower than those obtained with the standard RBE-weighted model (between 10% to 45%). The results also suggested that the probabilities of tumour control derived from photon iso-effective doses are more adequate to explain the clinical responses than those obtained with the RBE-weighted values. The dosimetry in the mucosa revealed that the photon iso-effective doses were about 30% to 50% higher than the corresponding RBE-weighted values. While the RBE-weighted doses are unable to predict mucosa toxicity, predictions based on the proposed

  15. Anticoagulation and high dose liver radiation. A preliminary report

    International Nuclear Information System (INIS)

    Lightdale, C.J.; Wasser, J.; Coleman, M.; Brower, M.; Tefft, M.; Pasmantier, M.

    1979-01-01

    Two groups of patients were observed for evidence of acute radiation hepatitis during high dose radiation to the liver. The first group of 18 patients with metastatic liver disease received an average of 4,050 rad to the whole liver. Half received anticoagulation with warfarin. One patient on anticoagulation developed evidence of acute radiation hepatitis while 2 patients did so without anticoagulation. Eleven patients with Hodgkin's disease received 4,000 rad to the left lobe of the liver during extended field radiation. Four of these 11 patients were anticoagulated to therapeutic range. Only one of the fully anticoagulated patients showed changes on liver scan consistent with radiation hepatitis whereas three did so without anticoagulation. No serious sequelae from anticoagulation occurred in either group. These preliminary data suggest that anticoagulation may be safely administered with high dose hepatic radiation and that further trials with anticoagulation are warranted

  16. PLUTONIUM/HIGH-LEVEL VITRIFIED WASTE BDBE DOSE CALCULATION

    Energy Technology Data Exchange (ETDEWEB)

    J.A. Ziegler

    2000-11-20

    The purpose of this calculation is to provide a dose consequence analysis of high-level waste (HLW) consisting of plutonium immobilized in vitrified HLW to be handled at the proposed Monitored Geologic Repository at Yucca Mountain for a beyond design basis event (BDBE) under expected conditions using best estimate values for each calculation parameter. In addition to the dose calculation, a plutonium respirable particle size for dose calculation use is derived. The current concept for this waste form is plutonium disks enclosed in cans immobilized in canisters of vitrified HLW (i.e., glass). The plutonium inventory at risk used for this calculation is selected from Plutonium Immobilization Project Input for Yucca Mountain Total Systems Performance Assessment (Shaw 1999). The BDBE examined in this calculation is a nonmechanistic initiating event and the sequence of events that follow to cause a radiological release. This analysis will provide the radiological releases and dose consequences for a postulated BDBE. Results may be considered in other analyses to determine or modify the safety classification and quality assurance level of repository structures, systems, and components. This calculation uses best available technical information because the BDBE frequency is very low (i.e., less than 1.0E-6 events/year) and is not required for License Application for the Monitored Geologic Repository. The results of this calculation will not be used as part of a licensing or design basis.

  17. Pathological consequences of chronic low daily dose gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Seed, T.M.; Miller, A.C.; Ramakrishnan, N. [Armed Forces Radiobiology Research Inst., Bethesda, MD (United States); Fritz, T.E.

    2000-07-01

    The quantitative relationships between the chronic radiation exposure parameters of dose-rate and total dose in relation to associated health risks was examined in dogs. At a dose-rate of 75, 128, and 263 mGy/d the incidence of acute lymphohematopoietic suppression (aplastic anemia) and associated septic complications was 73%, 87%, and 100%, respectively, and it increased in dose-dependent manner. By contrast, at dose-rates below 75 mGy/d, late cancers contributed significantly to the death of relatively long-lived animals, whose mean survival time was 1800 days. Myeloproliferative disease (MPD), mainly myeloid leukemia, was the dominant pathology seen at the higher daily dose-rates (18.8-75 mGy/d). When daily exposure was carried out continuously, the incidence of MPD was quite high. It should be noted that the induction radiation-induced MPD in this study was highly significant, because spontaneous MPD is exceedingly rare in the dog. However, when the daily dose-rate was reduced further or exposure was discontinued, the incidence of MPD declined significantly. At these lower dose-rates, solid tumors contributed heavily to the life-shortening effects of chronic irradiation. The induction and progression of these survival-compromising, late forms of pathology appeared to be driven by the degree of hematopoietic suppression that occurred early during the exposure phase, and in turn by the capacity of hematopoietic system to repair itself, recover, and to accommodate under chronic radiation stress. (K.H.)

  18. Hypofractionated stereotactic radiotherapy to the rat hippocampus. Determination of dose response and tolerance

    International Nuclear Information System (INIS)

    Ernst-Stecken, A.; Roedel, F.; Grabenbauer, G.; Sauer, R.; Jeske, I.; Bluemcke, I.; Hess, A.; Ganslandt, O.; Brune, K.

    2007-01-01

    Purpose: To determine the effect of hypofractionated stereotactic radiotherapy (hfSRT) on adult rat brain tissue (necrosis, impact on blood-brain barrier, signal changes on high-field magnetic resonance imaging [MRI]). Material and Methods: Adult male Wistar rats underwent MRI and CT scanning of the brain and respective images were introduced into the Novalis trademark radiosurgery device (BrainLab, Feldkirchen, Germany). All animals (body weight 350 g) were irradiated weekly with doses of 2 x 10 Gy (n = 3 animals), 3 x 10 Gy (n = 3 animals) and 4 x 10 Gy (n = 3 animals), targeted to the left hippocampus after image-guided positioning. 4.7-T T2-weighted MRI scanning was performed in each animal. Animals were sacrificed 8, 12, and 16 weeks after hfSRT and brains were immersion-fixed in 4% paraformaldehyde for subsequent histopathologic analysis. Results: In concordance with isodose distributions, pathologic signal hyperintensities in MRI were recorded from 4 x 10 Gy after 8 weeks, 3 x 10 Gy after 12 weeks, while 2 x 10 Gy induced slight detectable alterations only after 16 weeks. Subsequent histopathologic analysis revealed hippocampal cell necrosis with significantly earlier and stronger occurrence for higher doses (40 Gy > 30 Gy > 20 Gy). Pial microvessel permeability also increased after 40 Gy, whereas 30 Gy induced moderate changes. Conclusion: Conclusion: Partial-brain irradiation with hfSRT (Novalis trademark System) was successfully adopted for small animals and histopathologic analysis confirmed its repositioning accuracy. The neuropathologic effects correlated with dose and observation time. The approach will be further developed for quality assurance in hfSRT of normal brain tissue, as well as novel treatment modalities in epileptic rats and orthotopic tumor models. (orig.)

  19. Characterization of a high-purity germanium detector for small-animal SPECT.

    Science.gov (United States)

    Johnson, Lindsay C; Campbell, Desmond L; Hull, Ethan L; Peterson, Todd E

    2011-09-21

    We present an initial evaluation of a mechanically cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axes. Finally, a flood-corrected flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT.

  20. The effect of high-dose dronabinol (oral THC) maintenance on cannabis self-administration.

    Science.gov (United States)

    Schlienz, Nicolas J; Lee, Dustin C; Stitzer, Maxine L; Vandrey, Ryan

    2018-06-01

    There is a clear need for advancing the treatment of cannabis use disorders. Prior research has demonstrated that dronabinol (oral THC) can dose-dependently suppress cannabis withdrawal and reduce the acute effects of smoked cannabis. The present study was conducted to evaluate whether high-dose dronabinol could reduce cannabis self-administration among daily users. Non-treatment seeking daily cannabis users (N = 13) completed a residential within-subjects crossover study and were administered placebo, low-dose dronabinol (120 mg/day; 40 mg tid), or high-dose dronabinol (180-240 mg/day; 60-80 mg tid) for 12 consecutive days (order counterbalanced). During each 12-day dronabinol maintenance phase, participants were allowed to self-administer smoked cannabis containing <1% THC (placebo) or 5.7% THC (active) under forced-choice (drug vs. money) or progressive ratio conditions. Participants self-administered significantly more active cannabis compared with placebo in all conditions. When active cannabis was available, self-administration was significantly reduced during periods of dronabinol maintenance compared with placebo maintenance. There was no difference in self-administration between the low- and high-dose dronabinol conditions. Chronic dronabinol dosing can reduce cannabis self-administration in daily cannabis users and suppress withdrawal symptoms. Cannabinoid agonist medications should continue to be explored for therapeutic utility in the treatment of cannabis use disorders. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Animal Experimentation in High Schools

    Science.gov (United States)

    Ansevin, Kystyna D.

    1970-01-01

    Recommends that teacher and student be provided with the broadest possible spectrum of meaningful and feasible experiments in which the comfort of the experimental animal is protected by the design of the experiment. (BR)

  2. Biological X-ray irradiator characterization for use with small animals and cells.

    Science.gov (United States)

    Bruno, A Colello; Mazaro, S J; Amaral, L L; Rego, E M; Oliveira, H F; Pavoni, J F

    2017-03-02

    This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current), the radiometric survey (leakage radiation) and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1) and remained stable for long (constant) and short (repeatability) intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer). The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators) for cells and small animal irradiation, especially in early research stages.

  3. Biological X-ray irradiator characterization for use with small animals and cells

    Directory of Open Access Journals (Sweden)

    A. Colello Bruno

    Full Text Available This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current, the radiometric survey (leakage radiation and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1 and remained stable for long (constant and short (repeatability intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer. The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators for cells and small animal irradiation, especially in early research stages.

  4. Alanine-EPR dosimetry system for high industrial as well radiotherapeutic dose measurement

    International Nuclear Information System (INIS)

    Dobrovodsky, J.; Bukovjan, J.

    2005-01-01

    Slovak Institute of Metrology is developing new metrology standard for high doses, based on the alanine-EPR as a reference dosimetry system. A Bruker e-scan EPR analyser developed specifically for alanine dosimetry has improved stability of EPR measurement, especially at lower dose range. The standard e-scan system provides sensitivity below 1 Gray. After further improvement of the system and lowering of dose determination expanded uncertainty down below 1 %, its utilisation for radiotherapy field is expected (authors)

  5. Dose rate visualization of radioisotope thermoelectric generators

    International Nuclear Information System (INIS)

    Schwarz, R.A.; Kessler, S.F.; Tomaszewski, T.A.

    1995-09-01

    Advanced visualization techniques can be used to investigate gamma ray and neutron dose rates around complex dose rate intensive operations. A method has been developed where thousands of dose points are calculated using the MCNP(Monte Carlo N-Particle) computer code and then displayed to create color contour plots of the dose rate for complex geometries. Once these contour plots are created, they are sequenced together creating an animation to dynamically show how the dose rate changes with changes in the geometry or source over time

  6. Evaluation of glasses containing cadmium for high dose dosimetry by the thermoluminescence technique

    International Nuclear Information System (INIS)

    Carvalho, Gabriel Soares Marchiori de; Ferreira, Pamela Zati; Cunha, Diego Merigue da; Dantas, Noelio Oliveira; Silva, Anielle C.A.; Perini, Ana Paula; Neves, Lucio Pereira; Carrera, Betzabel Noemi Silva; Watanabe, Shigueo

    2016-01-01

    New glass matrices were evaluated for high dose dosimetry by the thermoluminescence technique. Their nominal composition are 20Li_2CO_3.10Al_2O_3.15CdO.55B_2O_3 and 20Li_2CO_3.10Al_2O_3.20CdO.50B_2O_3 (mol%). The glass matrices were irradiated with different doses: 50, 100, 200, 500, 700 and 900 Gy, and the thermoluminescence emission curves were obtained for each of these values. The results show a great potential of using these matrices in high dose dosimetry. (author)

  7. System for determining absorbed dose and its distribution for high-energy electron radiation

    International Nuclear Information System (INIS)

    Hegewald, H.; Wulff, W.

    1977-01-01

    Taking into account the polarization effect, the dose determination for high-energy electron radiation from particle accelerators depends on the knowledge of the energy dependence of the mass stopping power. Results obtained with thermoluminescent dosemeters agree with theoretical values. For absorbed dose measurements the primary energy of electron radiation has been determined by nuclear photoreactions, and the calculation of the absorbed dose from charge measurements by means of the mass stopping power is described. Thus the calibration of ionization chambers for high-energy electron radiation by absolute measurements with the Faraday cage and chemical dosemeters has become possible. (author)

  8. Australian high-dose-rate brachytherapy protocols for gynaecological malignancy

    International Nuclear Information System (INIS)

    MacLeod, C.; Dally, M.; Stevens, M.; Thornton, D.; Carruthers, S.; Jeal, P.

    2001-01-01

    There is no consensus over the optimal dose fractionation schedules for high-dose-rate (HDR) brachytherapy used for gynaecological malignancy. In Australian public hospital departments of radiation oncology, HDR brachytherapy for gynaecological cancer is being more commonly used. A survey of public departments that are using this technology, or that plan to introduce this technology, was performed. Their current protocols are presented. In general, protocols are similar biologically; however, the practical aspects such as the number of fractions given do vary and may reflect resource restrictions or, alternatively, differences in interpretations of the literature and of the best protocols by clinicians. Copyright (2001) Blackwell Science Pty Ltd

  9. Dosing algorithm to target a predefined AUC in patients with primary central nervous system lymphoma receiving high dose methotrexate.

    Science.gov (United States)

    Joerger, Markus; Ferreri, Andrés J M; Krähenbühl, Stephan; Schellens, Jan H M; Cerny, Thomas; Zucca, Emanuele; Huitema, Alwin D R

    2012-02-01

    There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h. A population covariate model from a pooled dataset of 131 patients receiving HDMTX was used to simulate concentration-time curves of 10,000 patients and test the efficacy of a dosing algorithm based on 24 h MTX plasma concentrations to target the prespecified AUC(MTX) . These data simulations included interindividual, interoccasion and residual unidentified variability. Patients received a total of four simulated cycles of HDMTX and adjusted MTX dosages were given for cycles two to four. The dosing algorithm proposes MTX dose adaptations ranging from +75% in patients with MTX C(24) 12 µmol l(-1). The proposed dosing algorithm resulted in a marked improvement of the proportion of patients within the AUC(MTX) target between 1000 and 1100 µmol l(-1) h (11% with standard MTX dose, 35% with the adjusted dose) and a marked reduction of the interindividual variability of MTX exposure. A simple and practical dosing algorithm for HDMTX has been developed based on MTX 24 h plasma concentrations, and its potential efficacy in improving the proportion of patients within a prespecified target AUC(MTX) and reducing the interindividual variability of MTX exposure has been shown by data simulations. The clinical benefit of this dosing algorithm should be assessed in patients with primary central nervous system lymphoma (PCNSL). © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.

  10. The motivations and methodology for high-throughput PET imaging of small animals in cancer research

    Energy Technology Data Exchange (ETDEWEB)

    Aide, Nicolas [Francois Baclesse Cancer Centre, Nuclear Medicine Department, Caen Cedex (France); Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Visser, Eric P. [Radboud University Nijmegen Medical Center, Nuclear Medicine Department, Nijmegen (Netherlands); Lheureux, Stephanie [Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Heutte, Natacha [Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Szanda, Istvan [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Hicks, Rodney J. [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia)

    2012-09-15

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has increased. This paper describes experimental design requirements to reach statistical significance, based on the expected change in tracer uptake in treated animals as compared to the control group, the number of groups that will be imaged, and the expected intra-animal variability for a given tracer. We also review how high-throughput studies can be performed in dedicated small-animal PET, high-resolution clinical PET systems and planar positron imaging systems by imaging more than one animal simultaneously. Customized beds designed to image more than one animal in large-bore small-animal PET scanners are described. Physics issues related to the presence of several rodents within the field of view (i.e. deterioration of spatial resolution and sensitivity as the radial and the axial offsets increase, respectively, as well as a larger effect of attenuation and the number of scatter events), which can be assessed by using the NEMA NU 4 image quality phantom, are detailed. (orig.)

  11. High Dose Ascorbate Causes Both Genotoxic and Metabolic Stress in Glioma Cells

    Science.gov (United States)

    Castro, Maria Leticia; Carson, Georgia M.; McConnell, Melanie J.; Herst, Patries M.

    2017-01-01

    We have previously shown that exposure to high dose ascorbate causes double stranded breaks (DSBs) and a build-up in S-phase in glioblastoma (GBM) cell lines. Here we investigated whether or not this was due to genotoxic stress as well as metabolic stress generated by exposure to high dose ascorbate, radiation, ascorbate plus radiation and H2O2 in established and primary GBM cell lines. Genotoxic stress was measured as phosphorylation of the variant histone protein, H2AX, 8-oxo-7,8-dihydroguanine (8OH-dG) positive cells and cells with comet tails. Metabolic stress was measured as a decrease in NADH flux, mitochondrial membrane potential (by CMXRos), ATP levels (by ATP luminescence) and mitochondrial superoxide production (by mitoSOX). High dose ascorbate, ascorbate plus radiation, and H2O2 treatments induced both genotoxic and metabolic stress. Exposure to high dose ascorbate blocked DNA synthesis in both DNA damaged and undamaged cell of ascorbate sensitive GBM cell lines. H2O2 treatment blocked DNA synthesis in all cell lines with and without DNA damage. DNA synthesis arrest in cells with damaged DNA is likely due to both genotoxic and metabolic stress. However, arrest in DNA synthesis in cells with undamaged DNA is likely due to oxidative damage to components of the mitochondrial energy metabolism pathway. PMID:28737676

  12. Aging of magnesium stearate under high doses gamma irradiation and oxidative conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lebeau, D.; Beuvier, L.; Cornaton, M. [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France); Miserque, F. [CEA, DEN, DPC, SCCME, LECA, F-91191 Gif-sur-Yvette (France); Tabarant, M. [CEA, DEN, DPC, SEARS, LISL, F-91191 Gif-sur-Yvette (France); Esnouf, S. [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France); Ferry, M., E-mail: muriel.ferry@cea.fr [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France)

    2015-05-15

    Highlights: • Magnesium stearate was radio-oxidized at very high doses using gamma-rays. • H{sub 2} emission was estimated as a function of the integrated dose. • Modifications in the organic solid were followed as a function of the integrated dose. • A non-exhaustive degradation mechanism of magnesium stearate was proposed. - Abstract: In nuclear waste packages conditioning processes, magnesium stearate is widely used because of its high lubricating properties. For safety purposes, the radiolytic degradation of these organic materials has to be better understood to be able to predict their aging in repository conditions. This study reports the radiolytic degradation of magnesium stearate, using gamma-rays at room temperature and under air. Modifications were followed using different analytical tools (XPS, ATR-FTIR, ICP-AES, ATG and mass spectrometry). It has been observed that molecules mainly formed up to 1000 kGy of gamma irradiation dose under radio-oxidation are alkanes, hydroperoxides, double bonds in the aliphatic chain, carboxylates with aliphatic chain shorter than the one of stearate and ketones. At a dose of 4000 kGy, dicarboxylic acids are observed: the formation of these molecules needs a dose of at least 1000 kGy to be created under radio-oxidation. These observations allow us to propose a non-exhaustive degradation mechanism of magnesium stearate under gamma-irradiation at room temperature and under air.

  13. A comparison of anti-tumor effects of high dose rate fractionated and low dose rate continuous irradiation in multicellular spheroids

    International Nuclear Information System (INIS)

    Kubota, Nobuo; Omura, Motoko; Matsubara, Sho.

    1997-01-01

    In a clinical experience, high dose rate (HDR) fractionated interstitial radiotherapy can be an alternative to traditional low dose rate (LDR) continuous interstitial radiotherapy for head and neck cancers. To investigate biological effect of HDR, compared to LDR, comparisons have been made using spheroids of human squamous carcinoma cells. Both LDR and HDR were delivered by 137 Cs at 37degC. Dose rate of LDR was 8 Gy/day and HDR irradiations of fraction size of 4, 5 or 6 Gy were applied twice a day with an interval time of more than 6 hr. We estimated HDR fractionated dose of 31 Gy with 4 Gy/fr to give the same biological effects of 38 Gy by continuous LDR for spheroids. The ratio of HDR/LDR doses to control 50% spheroids was 0.82. (author)

  14. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  15. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-01-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  16. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-10-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  17. Extreme implanting in Si: A study of ion-induced damage at high temperature and high dose

    International Nuclear Information System (INIS)

    Holland, O.W.

    1994-01-01

    Ion-solid interactions near room temperature and below have been well studied in single-crystal Si. While this has led to a better understanding of the mechanisms responsible for nucleation and growth of lattice damage during irradiation, these studies have not, in general, been extended to high temperatures (e.g., >200 degrees C). This is the case despite the commercialization of ion beam technologies which utilize high-temperature processing, such as separation by implantation of oxygen (SIMOX). In this process, a silicon-on-insulator (SOI) material is produced by implanting a high dose of oxygen ions into a Si wafer to form a buried, stoichiometric oxide layer. Results will be presented of a study of damage accumulation during high-dose implantation of Si at elevated temperatures. In particular, O + -ions were used because of the potential impact of the results on the SIMOX technology. It will be shown that the nature of the damage accumulation at elevated temperatures is quite distinctive and portends the presence of a new mechanism, one which is only dominant under the extreme conditions encountered during ion beam synthesis (i.e., high temperature and high dose). This mechanism is discussed and shown to be quite general and not dependent on the chemical identity of the ions. Also, techniques for suppressing this mechanism by open-quotes defect engineeringclose quotes are discussed. Such techniques are technologically relevant because they offer the possibility of reducing the defect density of the SOI produced by SIMOX

  18. High-LET dose-response characteristics by track structure theory of heavy charged particles

    International Nuclear Information System (INIS)

    Hansen, J.W.; Olsen, K.J.

    1981-09-01

    The track structure theory developed by Katz and co-workers ascribes the effect of high-LET radiation to the highly inhomogeneous dose distribution due to low energy Δ-rays ejected from the particle track. The theory predicts the effectiveness of high-LET radiation by using the ion parameters zsub(eff') effective charge of the ion, and β = v/c, the relative ion velocity, together with the characteristic dose D 37 derived from low-LET dose-response characteristic of the detector and the approximate size asub(0) of the sensitive element of the detector. 60 Co gamma-irradiation is used as a reference low-LET radiation, while high-LET radiation ranging from 16 MeV protons to 4 MeV/amu 16 0-ions covering an initial LET range of 30-5500 MeVcm 2 /g is obtained from a tandem Van de Graaff accelerator. A thin film (5mg/cm 2 ) radiochromic dye cyanide plastic dosemeter was used as detector with the characteristic dose of 16.8 Mrad and a sensitive element size of 10 -7 cm. Theoretical and experimental effectiveness, RBE, agreed within 10 to 25% depending on LET. (author)

  19. New observations on chronic intoxication by very small doses of sodium fluosilicate

    Energy Technology Data Exchange (ETDEWEB)

    Cristiani, H; Chausse, P

    1927-01-01

    It was determined that daily doses of approximately 0.1 of the lethal dose of sodium fluoride produced a fluoric cachexia in guinea pigs which caused the death of the animals in 2 or 3 months. Animals which were given 0.02 of the lethal dose of sodium fluoride were apparently in good health for a period of 10 months. However, after two or three years cachexia was likely to appear.

  20. Traces of natural radionuclides in animal food

    Energy Technology Data Exchange (ETDEWEB)

    Merli, Isabella Desan; Guazzelli da Silveira, Marcilei A. [Centro Universitário da FEI, São Bernardo do Campo (Brazil); Medina, Nilberto H. [Instituto de Física da USP, São Paulo (Brazil)

    2014-11-11

    Naturally occurring radioactive materials are present everywhere, e.g., in soil, air, housing materials, food, etc. Therefore, human beings and animals receive internal exposure from radioactive elements inside their bodies through breathing and alimentation. Gamma radiation has enough energy to remove an electron from the atom and compromise the rearrangement of electrons in the search for a more stable configuration which can disturb molecule chemical bonding. Food ingestion is one of the most common forms of radioisotopes absorption. The goal of this work is the measurement of natural gamma radiation rates from natural radioisotopes present in animal food. To determine the concentration of natural radionuclides present in animal food gamma-ray spectrometry was applied. We have prepared animal food samples for poultry, fish, dogs, cats and cattle. The two highest total ingestion effective doses observed refers to a sample of mineral salt cattle, 95.3(15) μSv/year, rabbit chow, with a value of 48(5) μSv/year, and cattle mineral salt, with a value of 69(7) μSv/year, while the annual total dose value from terrestrial intake radionuclide is of the order of 290 μSv/year.