  1. Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.

    Science.gov (United States)

    Masotti, Silvia; Prontera, Concetta; Musetti, Veronica; Storti, Simona; Ndreu, Rudina; Zucchelli, Gian Carlo; Passino, Claudio; Clerico, Aldo

    2018-02-23

    The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (cTnI), called Access hs-TnI using DxI platform, with those of Access AccuTnI+3 method, and high-sensitivity (hs) cTnI method for ARCHITECT platform. The limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of analytical performance and comparison of cTnI results, both heparinized plasma samples, collected from healthy subjects and patients with cardiac diseases, and quality control samples distributed in external quality assessment programs were used. LoB, LoD and LoQ at 20% and 10% CV values of the Access hs-cTnI method were 0.6, 1.3, 2.1 and 5.3 ng/L, respectively. Access hs-cTnI method showed analytical performance significantly better than that of Access AccuTnI+3 method and similar results to those of hs ARCHITECT cTnI method. Moreover, the cTnI concentrations measured with Access hs-cTnI method showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-cTnI methods, although there were systematic differences between these methods. There was no difference between cTnI values measured by Access hs-cTnI in heparinized plasma and serum samples, whereas there was a significant difference between cTnI values, respectively measured in EDTA and heparin plasma samples. Access hs-cTnI has analytical sensitivity parameters significantly improved compared to Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform.

  2. Performance benchmarking in cardiac imaging

    International Nuclear Information System (INIS)

    Schick, D.; Thiele, D.

    2004-01-01

    Full text: Diagnostic and interventional procedures performed in a cardiac catheter laboratory while demanding high image quality may also result in high patient radiation dose depending on the length or complexity of the procedure. Clinicians using the X-ray equipment require confidence that the system is operating optimally to ensure maximum benefit to the patient with minimum risk. 17 cardiac catheterisation laboratories have been surveyed using a phantom based on the NEMA XR 21 -2000 standard. The testing protocol measures spatial resolution, low contrast detectability, patient dose rate, dynamic range and motion blur for modes of operation and simulated patient sizes applicable to a diagnostic left heart catheter study. The combined results of the assessed laboratories are presented. The latest generation systems with flat-panel detectors exhibit better spatial resolution than older systems with image intensifiers. Phantom measurements show up to a 6 fold variation in dose rate across the range of systems assessed for a given patient size. As expected, some correlation between patient dose rate and the low contrast detectability score is evident. The extent of temporal filtering and pulse width is reflected in the motion blur score. The dynamic range measurements are found to be a less sensitive measure in evaluating system performance. Examination of patient dose results in the context of low contrast detectability score indicates that dose reduction could be achieved without compromising diagnosis on some systems. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  3. A High-Performance Fluorescence Immunoassay Based on the Relaxation of Quenching, Exemplified by Detection of Cardiac Troponin I

    Directory of Open Access Journals (Sweden)

    Seung-Wan Kim

    2016-05-01

    Full Text Available The intramolecular fluorescence self-quenching phenomenon is a major drawback in developing high-performance fluorometric biosensors which use common fluorophores as signal generators. We propose two strategies involving liberation of the fluorescent molecules by means of enzymatic fragmentation of protein or dehybridization of double-stranded DNA. In the former, bovine serum albumin (BSA was coupled with the fluorescent BODIPY dye (Red BSA, and then immobilized on a solid surface. When the insolubilized Red BSA was treated with proteinase K (10 units/mL for 30 min, the fluorescent signal was significantly increased (3.5-fold compared to the untreated control. In the second case, fluorophore-tagged DNA probes were linked to gold nanoparticles by hybridization with capture DNA strands densely immobilized on the surface. The quenched fluorescence signal was recovered (3.7-fold by thermal dehybridization, which was induced with light of a specific wavelength (e.g., 530 nm for less than 1 min. We next applied the Red BSA self-quenching relaxation technique employing enzymatic fragmentation to a high-performance immunoassay of cardiac troponin I (cTnI in a microtiter plate format. The detection limit was 0.19 ng/mL cTnI, and the fluorescent signal was enhanced approximately 4.1-fold compared with the conventional method of direct measurement of the fluorescent signal from a non-fragmented fluorophore-labeled antibody.

  4. Acrolein inhalation causes myocardial strain delay and decreased cardiac performance as detected by high-frequency echocardiography in mice

    Science.gov (United States)

    Acrolein, an unsaturated aldehyde found in air pollution, impairs Ca2+ flux and contraction in cardiomyocytes in vitro. To better define direct and delayed functional cardiac effects, we hypothesized that a single exposure to acrolein would modify myocardial strain and performanc...

  5. Acute effects of firefighting on cardiac performance.

    Science.gov (United States)

    Fernhall, Bo; Fahs, Christopher A; Horn, Gavin; Rowland, Thomas; Smith, Denise

    2012-02-01

    This study examined standard echocardiographic measures of cardiac size and performance in response to a 3-h firefighting training exercise. Forty experienced male personnel completed a standardized 3 h live firefighting exercise. Before and after the firefighting activities, participants were weighed, height, heart rate, blood pressure and blood samples were obtained, and echocardiographic measurements were made. Firefighting produced significant decreases in left ventricular diastolic dimension, stroke volume, fractional shortening, and mitral E velocity, tachycardia, a rise in core temperature, and a reduction in calculated plasma volume. On tissue Doppler imaging, there were no changes in systolic contractile function, but a decreased lateral wall diastolic velocity was observed. These findings show that 3 h of live firefighting produced cardiac changes consistent with cardiac fatigue, coupled with a decrease in systemic arterial compliance. These data show that live firefighting produces significant cardiovascular changes and future work is needed to evaluate if these changes are related to the increase in cardiovascular risk during live firefighting.

  6. Improving cardiac myocytes performance by CNTs platforms

    Directory of Open Access Journals (Sweden)

    Valentina eMartinelli

    2013-09-01

    Full Text Available The application of nanotechnology to the cardiovascular system has increasingly caught scientists’ attention as a potentially powerful tool for the development of new generation devices able to interface, repair or boost the performance of cardiac tissue. Carbon nanotubes (CNTs are considered as promising materials for nanomedicine applications in general and have been recently tested towards excitable cell growth. CNTs are cylindrically shaped structures made up of rolled-up graphene sheets, with unique electrical, thermal and mechanical properties, able to effectively conducting electrical current in electrochemical interfaces. CNTs-based scaffolds have been recently found to support the in vitro growth of cardiac cells: in particular, their ability to improve cardiomyocytes proliferation, maturation and electrical behavior are making CNTs extremely attractive for the development and exploitation of interfaces able to impact on cardiac cells physiology and function.

  7. Barriers and facilitators to learning and performing cardiopulmonary resuscitation in neighborhoods with low bystander cardiopulmonary resuscitation prevalence and high rates of cardiac arrest in Columbus, OH.

    Science.gov (United States)

    Sasson, Comilla; Haukoos, Jason S; Bond, Cindy; Rabe, Marilyn; Colbert, Susan H; King, Renee; Sayre, Michael; Heisler, Michele

    2013-09-01

    Residents who live in neighborhoods that are primarily black, Latino, or poor are more likely to have an out-of-hospital cardiac arrest, less likely to receive cardiopulmonary resuscitation (CPR), and less likely to survive. No prior studies have been conducted to understand the contributing factors that may decrease the likelihood of residents learning and performing CPR in these neighborhoods. The goal of this study was to identify barriers and facilitators to learning and performing CPR in 3 low-income, high-risk, and predominantly black neighborhoods in Columbus, OH. Community-Based Participatory Research approaches were used to develop and conduct 6 focus groups in conjunction with community partners in 3 target high-risk neighborhoods in Columbus, OH, in January to February 2011. Snowball and purposeful sampling, done by community liaisons, was used to recruit participants. Three reviewers analyzed the data in an iterative process to identify recurrent and unifying themes. Three major barriers to learning CPR were identified and included financial, informational, and motivational factors. Four major barriers were identified for performing CPR and included fear of legal consequences, emotional issues, knowledge, and situational concerns. Participants suggested that family/self-preservation, emotional, and economic factors may serve as potential facilitators in increasing the provision of bystander CPR. The financial cost of CPR training, lack of information, and the fear of risking one's own life must be addressed when designing a community-based CPR educational program. Using data from the community can facilitate improved design and implementation of CPR programs.

  8. Barriers and Facilitators to Learning and Performing Cardiopulmonary Resuscitation (CPR) in Neighborhoods with Low Bystander CPR Prevalence and High Rates of Cardiac Arrest in Columbus, Ohio

    Science.gov (United States)

    Sasson, Comilla; Haukoos, Jason S.; Bond, Cindy; Rabe, Marilyn; Colbert, Susan H.; King, Renee; Sayre, Michael; Heisler, Michele

    2013-01-01

    Background Residents who live in neighborhoods that are primarily African-American, Latino, or poor are more likely to have an out-of-hospital cardiac arrest (OHCA), less likely to receive cardiopulmonary resuscitation (CPR), and less likely to survive. No prior studies have been conducted to understand the contributing factors that may decrease the likelihood of residents learning and performing CPR in these neighborhoods. The goal of this study was to identify barriers and facilitators to learning and performing CPR in three low-income, “high-risk” predominantly African American, neighborhoods in Columbus, Ohio. Methods and Results Community-Based Participatory Research (CBPR) approaches were used to develop and conduct six focus groups in conjunction with community partners in three target high-risk neighborhoods in Columbus, Ohio in January-February 2011. Snowball and purposeful sampling, done by community liaisons, was used to recruit participants. Three reviewers analyzed the data in an iterative process to identify recurrent and unifying themes. Three major barriers to learning CPR were identified and included financial, informational, and motivational factors. Four major barriers were identified for performing CPR and included fear of legal consequences, emotional issues, knowledge, and situational concerns. Participants suggested that family/self-preservation, emotional, and economic factors may serve as potential facilitators in increasing the provision of bystander CPR. Conclusion The financial cost of CPR training, lack of information, and the fear of risking one's own life must be addressed when designing a community-based CPR educational program. Using data from the community can facilitate improved design and implementation of CPR programs. PMID:24021699

  9. High-performance liquid chromatography assay using ultraviolet detection for urinary quantification of milrinone concentrations in cardiac surgery patients undergoing cardiopulmonary bypass.

    Science.gov (United States)

    Gavra, Paul; Nguyen, Anne Q N; Beauregard, Natasha; Denault, André Y; Varin, France

    2014-08-01

    An analytical assay using liquid-liquid extraction and high-performance liquid chromatography with ultraviolet detection was developed for the quantification of total (conjugated and unconjugated) urinary concentrations of milrinone after the inhalation of a 5 mg dose in 15 cardiac patients undergoing cardiopulmonary bypass. Urine samples (700 μL) were extracted with ethyl-acetate and subsequently underwent acid back-extraction before and after deconjugation by mild acid hydrolysis. Milrinone was separated on a strong cation exchange analytical column. The mobile phase consisted of a constant mixture of acetonitrile:tetrahydrofurane-NaH2 PO4 buffer (40:60 v/v, pH 3.0). Thirteen calibration curves were linear in the concentration range of 31.25-4000 ng/mL, using olprinone as the internal standard (r(2) range 0.9911-0.9999, n = 13). Mean milrinone recovery and accuracy were respectively 85.2 ± 3.1% and ≥93%. Intra- and inter-day precisions (coefficients of variation) were ≤5% and ≤8%, respectively. Over a 24 h collection period, the cumulative urinary milrinone recovered from 15 patients was 26.1 ± 7.7% of the nominal 5 mg dose administered. The relative amount of milrinone glucuronic acid conjugate was negligible in the urine of patients undergoing cardiopulmonary bypass This method proved to be reliable, specific and accurate to determine the cumulative amount of total milrinone recovered in urine after inhalation. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Performance of highly sensitive cardiac troponin T assay to detect ischaemia at PET-CT in low-risk patients with acute coronary syndrome: a prospective observational study.

    Science.gov (United States)

    Morawiec, Beata; Fournier, Stephane; Tapponnier, Maxime; Prior, John O; Monney, Pierre; Dunet, Vincent; Lauriers, Nathalie; Recordon, Frederique; Trana, Catalina; Iglesias, Juan-Fernando; Kawecki, Damian; Boulat, Olivier; Bardy, Daniel; Lamsidri, Sabine; Eeckhout, Eric; Hugli, Olivier; Muller, Olivier

    2017-07-10

    Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented. To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain. Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography. Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively. Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value. ClinicalTrials.gov Identifier: NCT01374607. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly

  11. Assessment of calcium scoring performance in cardiac computed tomography

    International Nuclear Information System (INIS)

    Ulzheimer, Stefan; Kalender, Willi A.

    2003-01-01

    Electron beam tomography (EBT) has been used for cardiac diagnosis and the quantitative assessment of coronary calcium since the late 1980s. The introduction of mechanical multi-slice spiral CT (MSCT) scanners with shorter rotation times opened new possibilities of cardiac imaging with conventional CT scanners. The purpose of this work was to qualitatively and quantitatively evaluate the performance for EBT and MSCT for the task of coronary artery calcium imaging as a function of acquisition protocol, heart rate, spiral reconstruction algorithm (where applicable) and calcium scoring method. A cardiac CT semi-anthropomorphic phantom was designed and manufactured for the investigation of all relevant image quality parameters in cardiac CT. This phantom includes various test objects, some of which can be moved within the anthropomorphic phantom in a manner that mimics realistic heart motion. These tools were used to qualitatively and quantitatively demonstrate the accuracy of coronary calcium imaging using typical protocols for an electron beam (Evolution C-150XP, Imatron, South San Francisco, Calif.) and a 0.5-s four-slice spiral CT scanner (Sensation 4, Siemens, Erlangen, Germany). A special focus was put on the method of quantifying coronary calcium, and three scoring systems were evaluated (Agatston, volume, and mass scoring). Good reproducibility in coronary calcium scoring is always the result of a combination of high temporal and spatial resolution; consequently, thin-slice protocols in combination with retrospective gating on MSCT scanners yielded the best results. The Agatston score was found to be the least reproducible scoring method. The hydroxyapatite mass, being better reproducible and comparable on different scanners and being a physical quantitative measure, appears to be the method of choice for future clinical studies. The hydroxyapatite mass is highly correlated to the Agatston score. The introduced phantoms can be used to quantitatively assess the

  12. Metabolic and cardiac changes in high cholesterol-fructose-fed rats

    DEFF Research Database (Denmark)

    Axelsen, Lene N; Pedersen, Henrik D; Petersen, Jørgen S

    2010-01-01

    Introduction: High cholesterol-fructose (HCF) fed rats have previously been described as an animal model of impaired cardiac insulin signaling and decreased contractile performance. In this study, we evaluated the metabolic and cardiac effects of a HCF diet in rats. Methods: Male Sprague-Dawley r......Introduction: High cholesterol-fructose (HCF) fed rats have previously been described as an animal model of impaired cardiac insulin signaling and decreased contractile performance. In this study, we evaluated the metabolic and cardiac effects of a HCF diet in rats. Methods: Male Sprague...

  13. Temperature effects on aerobic scope and cardiac performance of European perch (Perca fluviatilis).

    Science.gov (United States)

    Jensen, Denise Lyager; Overgaard, Johannes; Wang, Tobias; Gesser, Hans; Malte, Hans

    2017-08-01

    Several recent studies have highlighted how impaired cardiac performance at high temperatures and in hypoxia may compromise the capacity for oxygen transport. Thus, at high temperatures impaired cardiac capacity is proposed to reduce oxygen transport to a degree that lowers aerobic scope and compromises thermal tolerance (the oxygen- and capacity-limited thermal tolerance (OCLTT) hypothesis). To investigate this hypothesis, we measured aerobic and cardiac performance of a eurythermal freshwater teleost, the European perch (Perca fluviatilis). Rates of oxygen consumption were measured during rest and activity at temperatures between 5°C and 27°C, and we evaluated cardiac function by in vivo measurements of heart rate and in vitro studies to determine contractility of myocardial strips. Aerobic scope increased progressively from 5°C to 21°C, after which it levelled off. Heart rate showed a similar response. We found little difference between resting and active heart rate at high temperature suggesting that increased cardiac scope during activity is primarily related to changes in stroke volume. To examine the effects of temperature on cardiac capacity, we measured isometric force development in electrically paced myocardial preparations during different combinations of temperature, pacing frequency, oxygenation and adrenergic stimulation. The force-frequency product increased markedly upon adrenergic stimulation at 21 and 27°C (with higher effects at 21°C) and the cardiac preparations were highly sensitive to hypoxia. These findings suggest that at (critically) high temperatures, cardiac output may diminish due to a decreased effect of adrenergic stimulation and that this effect may be further exacerbated if the heart becomes hypoxic. Hence cardiac limitations may contribute to the inability to increase aerobic scope at high temperatures in the European perch (Perca fluviatilis). Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Cardiac Output and Performance during a Marathon Race in Middle-Aged Recreational Runners

    OpenAIRE

    Billat, Véronique L.; Petot, Hélène; Landrain, Morgan; Meilland, Renaud; Koralsztein, Jean Pierre; Mille-Hamard, Laurence

    2012-01-01

    Purpose. Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV) and cardiac output (CO) to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance) and/or CO, per meter (i.e., cardiac cost). Methods. We measured the SV, heart rate (HR), CO, and running speed of 14 recreational runners in an incremental, maxima...

  15. Performance evaluation of cardiac MRI image denoising techniques

    NARCIS (Netherlands)

    AlAttar, M.A.; Mohamed, A.G.A.; Osman, N.F.; Fahmy, A.S.

    2008-01-01

    Black-blood cardiac magnetic resonance imaging (MRI) plays an important role in diagnosing a number of heart diseases. The technique suffers inherently from low contrast-to-noise ratio between the myocardium and the blood. In this work, we examined the performance of different classification

  16. UCP3 Ablation Exacerbates High-Salt Induced Cardiac Hypertrophy and Cardiac Dysfunction

    Directory of Open Access Journals (Sweden)

    Hongmei Lang

    2018-04-01

    Full Text Available Background/Aims: Excessive salt intake and left ventricular hypertrophy (LVH are both critical for the development of hypertension and heart failure. The uncoupling protein 3 (UCP3 plays a cardio-protective role in early heart failure development. However, the potential role for UCP3 in salt intake and LVH is unclear. Methods: UCP3-/- and C57BL/6 mice were placed on either a normal-salt (NS, 0.5% or a high-salt (HS, 8% diet for 24 weeks. The cardiac function, endurance capacity, energy expenditure, and mitochondrial functional capacity were measured in each group. Results: Elevated blood pressure was only observed in HS-fed UCP3-/- mice. High salt induced cardiac hypertrophy and dysfunction were observed in both C57BL/6 and UCP3-/- mice. However, the cardiac lesions were more profound in HS-fed UCP3-/- mice. Furthermore, HS-fed UCP3-/-mice experienced more severe mitochondrial respiratory dysfunction compared with HS-fed C57BL/6 mice, represented by the decreased volume of oxygen consumption and heat production at the whole-body level. Conclusion: UCP3 protein was involved in the incidence of high-salt induced hypertension and the progression of cardiac dysfunction in the early stages of heart failure. UCP3 ablation exacerbated high-salt-induced cardiac hypertrophy and cardiac dysfunction.

  17. Cardiac output and performance during a marathon race in middle-aged recreational runners.

    Science.gov (United States)

    Billat, Véronique L; Petot, Hélène; Landrain, Morgan; Meilland, Renaud; Koralsztein, Jean Pierre; Mille-Hamard, Laurence

    2012-01-01

    Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV) and cardiac output (CO) to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance) and/or CO, per meter (i.e., cardiac cost). We measured the SV, heart rate (HR), CO, and running speed of 14 recreational runners in an incremental, maximal laboratory test and then during a real marathon race (mean performance: 3 hr 30 min ± 45 min). Our data revealed that HR, SV and CO were all in a high but submaximal steady state during the marathon (87.0 ± 1.6%, 77.2 ± 2.6%, and 68.7 ± 2.8% of maximal values, respectively). Marathon performance was inversely correlated with an upward drift in the CO/speed ratio (mL of CO × m(-1)) (r = -0.65, P marathon performance is inversely correlated with cardiac cost and positively correlated with cardiac endurance. The CO response could be a benchmark for race performance in recreational marathon runners.

  18. Cardiac Output and Performance during a Marathon Race in Middle-Aged Recreational Runners

    Directory of Open Access Journals (Sweden)

    Véronique L. Billat

    2012-01-01

    Full Text Available Purpose. Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV and cardiac output (CO to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance and/or CO, per meter (i.e., cardiac cost. Methods. We measured the SV, heart rate (HR, CO, and running speed of 14 recreational runners in an incremental, maximal laboratory test and then during a real marathon race (mean performance: 3 hr 30 min ± 45 min. Results. Our data revealed that HR, SV and CO were all in a high but submaximal steady state during the marathon (87.0 ± 1.6%, 77.2 ± 2.6%, and 68.7 ± 2.8% of maximal values, respectively. Marathon performance was inversely correlated with an upward drift in the CO/speed ratio (mL of CO×m−1 (r=−0.65, P<0.01 and positively correlated with the runner’s ability to complete the race at a high percentage of the speed at maximal SV (r=0.83, P<0.0002. Conclusion. Our results showed that marathon performance is inversely correlated with cardiac cost and positively correlated with cardiac endurance. The CO response could be a benchmark for race performance in recreational marathon runners.

  19. High Speed impedance tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Tehrani, J.N.; Jin, C.; Schaik, Andre

    2010-01-01

    Full text: Electrical Impedance Tomography (EIT) calculates the internal conductivity distribution within a body using electrical contact measurements. Previous investigation has shown that optimizing electrode placement can give better information about the stroke volume and better separation between the ventricles and atria than with the electrodes attached in the transverse plane. In our investigation we are developing fast three dimensional imaging of the heart (two planes of 16 electrodes) including internal electrodes in esophagus. The reconstruction speed in EIT is one of the main limitations for real time imaging when using a detailed three dimensional finite element mesh. For that reason we investigated new iterative algorithms for solving large scale LJ regularization. In this research we compare these algorithms on noise reliability and speed for 2D cardiac models. The four methods were as follows: (I) an interior point method for solving Ll-regularized least squares problems (Ll-LS); (2) total variation using a Lagrangian multiplier (TV AL3); (3) a two step iterative shrinkage/thresholding method (TWIST) for solving the Lo-regularized least squares problem; (4) The Least Absolute Shrinkage and Selection Operator (LASSO). In our investigation, using 1600 elements, we found all four algorithms provided an improvement over the best conventional EIT reconstruction method, Total Variation, in three important areas: robustness to noise, increased computational speed of at least 40 x and a visually apparent improvement in spatial resolution. Out of the four algorithms we found TWIST was the fastest with at least a 1 00 x speed increase. (author)

  20. Practical applications and methods in performing cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Markovic, D.M.; Withrow, S.; Moodie, D.S.

    1986-01-01

    One of the purposes of this book is to outline the utility of digital subtraction angiography (DSA) in common clinical practice. No text has dealt with the actual physical setup of the room or the patient prior and during a digital subtraction angiographic study at rest and with exercise. This chapter outlines the steps commonly used when cardiac DSA is performed on patients in the authors' laboratory. The authors have learned over the last few years the best way to prepare the patient and the equipment and it is hoped that utilizing this experience, other centers may avoid the mistakes the authors have made in the past and develop new techniques for the future

  1. Extracellular high-mobility group box 1 mediates pressure overload-induced cardiac hypertrophy and heart failure.

    Science.gov (United States)

    Zhang, Lei; Liu, Ming; Jiang, Hong; Yu, Ying; Yu, Peng; Tong, Rui; Wu, Jian; Zhang, Shuning; Yao, Kang; Zou, Yunzeng; Ge, Junbo

    2016-03-01

    Inflammation plays a key role in pressure overload-induced cardiac hypertrophy and heart failure, but the mechanisms have not been fully elucidated. High-mobility group box 1 (HMGB1), which is increased in myocardium under pressure overload, may be involved in pressure overload-induced cardiac injury. The objectives of this study are to determine the role of HMGB1 in cardiac hypertrophy and cardiac dysfunction under pressure overload. Pressure overload was imposed on the heart of male wild-type mice by transverse aortic constriction (TAC), while recombinant HMGB1, HMGB1 box A (a competitive antagonist of HMGB1) or PBS was injected into the LV wall. Moreover, cardiac myocytes were cultured and given sustained mechanical stress. Transthoracic echocardiography was performed after the operation and sections for histological analyses were generated from paraffin-embedded hearts. Relevant proteins and genes were detected. Cardiac HMGB1 expression was increased after TAC, which was accompanied by its translocation from nucleus to both cytoplasm and intercellular space. Exogenous HMGB1 aggravated TAC-induced cardiac hypertrophy and cardiac dysfunction, as demonstrated by echocardiographic analyses, histological analyses and foetal cardiac genes detection. Nevertheless, the aforementioned pathological change induced by TAC could partially be reversed by HMGB1 inhibition. Consistent with the in vivo observations, mechanical stress evoked the release and synthesis of HMGB1 in cultured cardiac myocytes. This study indicates that the activated and up-regulated HMGB1 in myocardium, which might partially be derived from cardiac myocytes under pressure overload, may be of crucial importance in pressure overload-induced cardiac hypertrophy and cardiac dysfunction. © 2015 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  2. A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

    Science.gov (United States)

    Schmitt, Melanie; Potthast, Andreas; Sosnovik, David E; Polimeni, Jonathan R; Wiggins, Graham C; Triantafyllou, Christina; Wald, Lawrence L

    2008-06-01

    A 128-channel receive-only array coil is described and tested for cardiac imaging at 3T. The coil is closely contoured to the body with a "clam-shell" geometry with 68 posterior and 60 anterior elements, each 75 mm in diameter, and arranged in a continuous overlapped array of hexagonal symmetry to minimize nearest neighbor coupling. Signal-to-noise ratio (SNR) and noise amplification for parallel imaging (G-factor) were evaluated in phantom and volunteer experiments. These results were compared to those of commercially available 24-channel and 32-channel coils in routine use for cardiac imaging. The in vivo measurements with the 128-channel coil resulted in SNR gains compared to the 24-channel coil (up to 2.2-fold in the apex). The 128- and 32-channel coils showed similar SNR in the heart, likely dominated by the similar element diameters of these coils. The maximum G-factor values were up to seven times better for a seven-fold acceleration factor (R=7) compared to the 24-channel coil and up to two-fold improved compared to the 32-channel coil. The ability of the 128-channel coil to facilitate highly accelerated cardiac imaging was demonstrated in four volunteers using acceleration factors up to seven-fold (R=7) in a single spatial dimension. Copyright (c) 2008 Wiley-Liss, Inc.

  3. The effectiveness of and satisfaction with high-fidelity simulation to teach cardiac surgical resuscitation skills to nurses.

    Science.gov (United States)

    McRae, Marion E; Chan, Alice; Hulett, Renee; Lee, Ai Jin; Coleman, Bernice

    2017-06-01

    There are few reports of the effectiveness or satisfaction with simulation to learn cardiac surgical resuscitation skills. To test the effect of simulation on the self-confidence of nurses to perform cardiac surgical resuscitation simulation and nurses' satisfaction with the simulation experience. A convenience sample of sixty nurses rated their self-confidence to perform cardiac surgical resuscitation skills before and after two simulations. Simulation performance was assessed. Subjects completed the Satisfaction with Simulation Experience scale and demographics. Self-confidence scores to perform all cardiac surgical skills as measured by paired t-tests were significantly increased after the simulation (d=-0.50 to 1.78). Self-confidence and cardiac surgical work experience were not correlated with time to performance. Total satisfaction scores were high (mean 80.2, SD 1.06) indicating satisfaction with the simulation. There was no correlation of the satisfaction scores with cardiac surgical work experience (τ=-0.05, ns). Self-confidence scores to perform cardiac surgical resuscitation procedures were higher after the simulation. Nurses were highly satisfied with the simulation experience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. High performance homes

    DEFF Research Database (Denmark)

    Beim, Anne; Vibæk, Kasper Sánchez

    2014-01-01

    Can prefabrication contribute to the development of high performance homes? To answer this question, this chapter defines high performance in more broadly inclusive terms, acknowledging the technical, architectural, social and economic conditions under which energy consumption and production occur....... Consideration of all these factors is a precondition for a truly integrated practice and as this chapter demonstrates, innovative project delivery methods founded on the manufacturing of prefabricated buildings contribute to the production of high performance homes that are cost effective to construct, energy...

  5. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  6. Diagnostic and prognostic value of high-sensitivity cardiac troponin T in patients with syncope.

    Science.gov (United States)

    Christ, Michael; Geier, Felicitas; Popp, Steffen; Singler, Katrin; Smolarsky, Alexander; Bertsch, Thomas; Müller, Christian; Greve, Yvonne

    2015-02-01

    We examined the diagnostic and predictive value of high-sensitivity cardiac troponin T (cTnThs) in patients with syncope. We performed an analysis of consecutive patients with syncope presenting to the emergency department. The primary end point was the accuracy to diagnose a cardiac syncope. In addition, the study explored the prognostic relevance of cTnThs in patients with cardiac and noncardiac syncope. A total of 360 patients were enrolled (median age, 70.5 years; male, 55.8%; 23.9% aged >80 years). Cardiac syncope was present in 22% of patients, reflex syncope was present in 40% of patients, syncope due to orthostatic hypotension was present in 20% of patients, and unexplained syncope was present in 17.5% of patients. A total of 148 patients (41%) had cTnThs levels above the 99% confidence interval (CI) (cutoff point). The diagnostic accuracy for cTnThs levels to determine the diagnosis of cardiac syncope was quantified by the area under the curve (0.77; CI, 0.72-0.83; P value of cTnThs levels within 30 days: Patients with increased cTnThs levels had a 52% likelihood for adverse events, patients with cTnThs levels below the cutoff point had a low risk (negative predictive value, 83.5%). Increased cTnThs levels indicate adverse prognosis in patients with noncardiac causes of syncope, but not in patients with cardiac syncope being a risk factor for adverse outcome by itself. Patients with syncope presenting to the emergency department have a high proportion of life-threatening conditions. cTnThs levels show a limited diagnostic and predictive accuracy for the identification of patients with syncope at high risk. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. High-sensitivity Cardiac Troponin Elevation after Electroconvulsive Therapy (ECT)

    Science.gov (United States)

    Duma, Andreas; Pal, Swatilika; Johnston, Joshua; Helwani, Mohammad A.; Bhat, Adithya; Gill, Bali; Rosenkvist, Jessica; Cartmill, Christopher; Brown, Frank; Miller, J. Philip; Scott, Mitchell G; Sanchez-Conde, Francisco; Jarvis, Michael; Farber, Nuri B.; Zorumski, Charles F.; Conway, Charles; Nagele, Peter

    2017-01-01

    Background While electroconvulsive therapy (ECT) is widely regarded as a life-saving and safe procedure, evidence regarding its effects on myocardial cell injury are sparse. The objective of this investigation was to determine incidence and magnitude of new cardiac troponin elevation after ECT using a novel high-sensitivity cardiac troponin I (hscTnI) assay. Methods This was a prospective cohort study in adult patients undergoing ECT in a single academic center (up to three ECT treatments per patient). The primary outcome was new hscTnI elevation after ECT, defined as an increase of hscTnI >100% after ECT compared to baseline with at least one value above the limit of quantification (10 ng/L). 12-lead ECG and hscTnI values were obtained prior to and 15–30 minutes after ECT; in a subset of patients an additional 2-hour hscTnI value was obtained. Results The final study population was 100 patients and a total of 245 ECT treatment sessions. Eight patients (8/100, 8%) experienced new hscTnI elevation after ECT with a cumulative incidence of 3.7% (9/245 treatments; one patient had two hscTnI elevations), two of whom had a non-ST-elevation myocardial infarction (incidence 2/245, 0.8%). Median hscTnI concentrations did not increase significantly after ECT. Tachycardia and/or elevated systolic blood pressure developed after approximately two thirds of ECT treatments. Conclusions ECT appears safe from a cardiac standpoint in a large majority of patients. A small subset of patients with pre-existing cardiovascular risk factors, however, may develop new cardiac troponin elevation after ECT, the clinical relevance of which is unclear in the absence of signs of myocardial ischemia. PMID:28166110

  8. High performance systems

    Energy Technology Data Exchange (ETDEWEB)

    Vigil, M.B. [comp.

    1995-03-01

    This document provides a written compilation of the presentations and viewgraphs from the 1994 Conference on High Speed Computing given at the High Speed Computing Conference, {open_quotes}High Performance Systems,{close_quotes} held at Gleneden Beach, Oregon, on April 18 through 21, 1994.

  9. Evaluation of a high-sensitivity assay for measurement of canine and feline serum cardiac troponin I

    DEFF Research Database (Denmark)

    Langhorn, Rebecca; Willesen, Jakob; Tarnow, Inge

    2013-01-01

    Cardiac troponins are established as the gold standard biomarkers for acute cardiac injury. As even small elevations of cardiac troponins have prognostic relevance in people, it is important to investigate the performance of sensitive assays for use in veterinary medicine....

  10. Association between Hypotension, Low Ejection Fraction and Cognitive Performance in Cardiac Patients

    Directory of Open Access Journals (Sweden)

    Rebecca F. Gottesman

    2010-01-01

    Full Text Available Background and Purpose: Impaired cardiac function can adversely affect the brain via decreased perfusion. The purpose of this study was to determine if cardiac ejection fraction (EF is associated with cognitive performance, and whether this is modified by low blood pressure.

  11. Responsive design high performance

    CERN Document Server

    Els, Dewald

    2015-01-01

    This book is ideal for developers who have experience in developing websites or possess minor knowledge of how responsive websites work. No experience of high-level website development or performance tweaking is required.

  12. High Performance Macromolecular Material

    National Research Council Canada - National Science Library

    Forest, M

    2002-01-01

    .... In essence, most commercial high-performance polymers are processed through fiber spinning, following Nature and spider silk, which is still pound-for-pound the toughest liquid crystalline polymer...

  13. Impact of cardiac symptoms on self-reported household task performance in women with coronary artery disease.

    Science.gov (United States)

    Kimble, L P

    2001-01-01

    Household tasks are highly salient physical activities for women. Inability to perform household tasks may serve as an important marker of limitations imposed by cardiac symptoms. The purpose of this study was to examine the impact of cardiac symptoms on perceived ability to perform household tasks in women with coronary artery disease and to examine relationships among age, whether the woman lived alone, ability to perform household tasks, and cardiac-related quality of life. Forty-one women with confirmed diagnosis of coronary artery disease and a mean age of 66 years (SD 12 years) were interviewed about the impact of their cardiac symptoms and perceived ability to perform household tasks (Household Activities Scale) and cardiac-related quality of life (Seattle Angina Questionnaire). The women were primarily white (89.4%) and retired (65.9%). Forty-six percent were married, and 26.8% lived alone. "Washing dishes" (51.3%) was the only task a majority of the sample could perform without limitation. Household tasks most commonly reported as no longer performed included carrying laundry (24.4%), vacuuming (30.0%), and scrubbing the floor (51.2%). The task most commonly modified because of cardiac symptoms was changing bed linens (60%). Of the 14 household tasks, women performed a mean of 3.39 (SD 3.36) activities without difficulty. Total number of household activities performed without difficulty was associated with better quality of life in the area of exertional capacity (r = 0.50, P = 0.001). Women who lived alone reported greater perceived ability to perform household tasks than women who did not live alone (r = 0.31, P = 0.05). Age was not significantly associated with perceived household task performance (r = -0.22, P = 0.17). Women with coronary artery disease (CAD) perceived cardiac symptoms as disrupting their ability to perform household tasks. Future research is needed to determine the independent impact of cardiac symptoms on functional limitations

  14. Cardiac troponins--Translational biomarkers in cardiology: Theory and practice of cardiac troponin high-sensitivity assays.

    Science.gov (United States)

    Adamcova, Michaela; Popelova-Lencova, Olga; Jirkovsky, Eduard; Simko, Fedor; Gersl, Vladimir; Sterba, Martin

    2016-01-01

    Tn is a unique translational biomarker in cardiology whose potential has not been diminished in the new era of high sensitive assays. cTns can be valuable markers in cardiac diseases as well as in infectious diseases and respiratory diseases. Furthermore, the role of cTns is growing in the routine evaluation of cardioxicity and in determining the efficacy/safety ratio of novel cardioprotective strategies in clinical settings. cTns can detect myocardial injury not only in a wide spectrum of laboratory animals in experimental studies in vivo, but also in isolated heart models or cardiomyocytes in vitro. The crucial issue regarding the cross-species usage of cardiac troponin investigation remains the choice of cardiac troponin testing. This review summarizes the recent proteomic data on aminoacid sequences of cTnT and cTnI in various species, as well as selected analytical characteristics of human cardiac troponin high-sensitivity assays. Due to the highly phylogenetically conserved structure of troponins, the same bioindicator can be investigated using the same method in both clinical and experimental cardiology, thus contributing to a better understanding of the pathogenesis of cardiac diseases as well as to increased effectiveness of troponin use in clinical practice. Measuring cardiac troponins using commercially available human high-sensitivity cardiac troponin tests with convenient antibodies selected on the basis of adequate proteomic knowledge can solve many issues which would otherwise be difficult to address in clinical settings for various ethical and practical reasons. Our survey could help elaborate the practical guidelines for optimizing the choice of cTns assay in cardiology. © 2016 International Union of Biochemistry and Molecular Biology.

  15. Clojure high performance programming

    CERN Document Server

    Kumar, Shantanu

    2013-01-01

    This is a short, practical guide that will teach you everything you need to know to start writing high performance Clojure code.This book is ideal for intermediate Clojure developers who are looking to get a good grip on how to achieve optimum performance. You should already have some experience with Clojure and it would help if you already know a little bit of Java. Knowledge of performance analysis and engineering is not required. For hands-on practice, you should have access to Clojure REPL with Leiningen.

  16. High Performance Concrete

    Directory of Open Access Journals (Sweden)

    Traian Oneţ

    2009-01-01

    Full Text Available The paper presents the last studies and researches accomplished in Cluj-Napoca related to high performance concrete, high strength concrete and self compacting concrete. The purpose of this paper is to raid upon the advantages and inconveniences when a particular concrete type is used. Two concrete recipes are presented, namely for the concrete used in rigid pavement for roads and another one for self-compacting concrete.

  17. High performance polymeric foams

    International Nuclear Information System (INIS)

    Gargiulo, M.; Sorrentino, L.; Iannace, S.

    2008-01-01

    The aim of this work was to investigate the foamability of high-performance polymers (polyethersulfone, polyphenylsulfone, polyetherimide and polyethylenenaphtalate). Two different methods have been used to prepare the foam samples: high temperature expansion and two-stage batch process. The effects of processing parameters (saturation time and pressure, foaming temperature) on the densities and microcellular structures of these foams were analyzed by using scanning electron microscopy

  18. High performance conductometry

    International Nuclear Information System (INIS)

    Saha, B.

    2000-01-01

    Inexpensive but high performance systems have emerged progressively for basic and applied measurements in physical and analytical chemistry on one hand, and for on-line monitoring and leak detection in plants and facilities on the other. Salient features of the developments will be presented with specific examples

  19. Danish High Performance Concretes

    DEFF Research Database (Denmark)

    Nielsen, M. P.; Christoffersen, J.; Frederiksen, J.

    1994-01-01

    In this paper the main results obtained in the research program High Performance Concretes in the 90's are presented. This program was financed by the Danish government and was carried out in cooperation between The Technical University of Denmark, several private companies, and Aalborg University...... concretes, workability, ductility, and confinement problems....

  20. High performance homes

    DEFF Research Database (Denmark)

    Beim, Anne; Vibæk, Kasper Sánchez

    2014-01-01

    . Consideration of all these factors is a precondition for a truly integrated practice and as this chapter demonstrates, innovative project delivery methods founded on the manufacturing of prefabricated buildings contribute to the production of high performance homes that are cost effective to construct, energy...

  1. High-Performance Networking

    CERN Multimedia

    CERN. Geneva

    2003-01-01

    The series will start with an historical introduction about what people saw as high performance message communication in their time and how that developed to the now to day known "standard computer network communication". It will be followed by a far more technical part that uses the High Performance Computer Network standards of the 90's, with 1 Gbit/sec systems as introduction for an in depth explanation of the three new 10 Gbit/s network and interconnect technology standards that exist already or emerge. If necessary for a good understanding some sidesteps will be included to explain important protocols as well as some necessary details of concerned Wide Area Network (WAN) standards details including some basics of wavelength multiplexing (DWDM). Some remarks will be made concerning the rapid expanding applications of networked storage.

  2. Swimming performance, venous oxygen tension and cardiac performance of coronary-ligated rainbow trout, Oncorhynchus mykiss, exposed to progressive hypoxia

    DEFF Research Database (Denmark)

    Steffensen, J F; Farrell, A P

    1998-01-01

    We performed in vivo studies to examine the idea that cardiac work is impaired in rainbow trout (Oncorhynchus mykiss) below a certain venous PO2 threshold. We hypothesized that coronary-ligated fish, swimming continuously at a reasonably high water velocity (1.5 body lengths x s(-1)) and exposed...... to progressive hypoxia, would fatigue at higher venous PO2 and ambient water PO2 compared with sham-operated fish. However, we found that both the lowest venous PO2 that supported hypoxic swimming (9.9 torr for coronary-ligated fish and 11.1 torr for sham-operated fish) and the venous PO2 at fatigue (7.8 torr...... and 8.6 torr, respectively) were the same for coronary-ligated and sham-operated fish. Also, both groups quit swimming at the same water PO2 heart rate and hematocrit. Nevertheless, significant differences in cardiac performance did exist between the two groups. Whereas ventral aortic blood pressure...

  3. Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

    International Nuclear Information System (INIS)

    Wang Min; Qi Hengtao; Wang Ximing; Wang Tao; Chen, Jiu-Hong; Liu Cheng

    2009-01-01

    Objective: To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates ( 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P 70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.

  4. High performance data transfer

    Science.gov (United States)

    Cottrell, R.; Fang, C.; Hanushevsky, A.; Kreuger, W.; Yang, W.

    2017-10-01

    The exponentially increasing need for high speed data transfer is driven by big data, and cloud computing together with the needs of data intensive science, High Performance Computing (HPC), defense, the oil and gas industry etc. We report on the Zettar ZX software. This has been developed since 2013 to meet these growing needs by providing high performance data transfer and encryption in a scalable, balanced, easy to deploy and use way while minimizing power and space utilization. In collaboration with several commercial vendors, Proofs of Concept (PoC) consisting of clusters have been put together using off-the- shelf components to test the ZX scalability and ability to balance services using multiple cores, and links. The PoCs are based on SSD flash storage that is managed by a parallel file system. Each cluster occupies 4 rack units. Using the PoCs, between clusters we have achieved almost 200Gbps memory to memory over two 100Gbps links, and 70Gbps parallel file to parallel file with encryption over a 5000 mile 100Gbps link.

  5. Educational program in crisis management for cardiac surgery teams including high realism simulation.

    Science.gov (United States)

    Stevens, Louis-Mathieu; Cooper, Jeffrey B; Raemer, Daniel B; Schneider, Robert C; Frankel, Allan S; Berry, William R; Agnihotri, Arvind K

    2012-07-01

    Cardiac surgery demands effective teamwork for safe, high-quality care. The objective of this pilot study was to develop a comprehensive program to sharpen performance of experienced cardiac surgical teams in acute crisis management. We developed and implemented an educational program for cardiac surgery based on high realism acute crisis simulation scenarios and interactive whole-unit workshop. The impact of these interventions was assessed with postintervention questionnaires, preintervention and 6-month postintervention surveys, and structured interviews. The realism of the acute crisis simulation scenarios gradually improved; most participants rated both the simulation and whole-unit workshop as very good or excellent. Repeat simulation training was recommended every 6 to 12 months by 82% of the participants. Participants of the interactive workshop identified 2 areas of highest priority: encouraging speaking up about critical information and interprofessional information sharing. They also stressed the importance of briefings, early communication of surgical plan, knowing members of the team, and continued simulation for practice. The pre/post survey response rates were 70% (55/79) and 66% (52/79), respectively. The concept of working as a team improved between surveys (P = .028), with a trend for improvement in gaining common understanding of the plan before a procedure (P = .075) and appropriate resolution of disagreements (P = .092). Interviewees reported that the training had a positive effect on their personal behaviors and patient care, including speaking up more readily and communicating more clearly. Comprehensive team training using simulation and a whole-unit interactive workshop can be successfully deployed for experienced cardiac surgery teams with demonstrable benefits in participant's perception of team performance. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. Journey to top performance: a multipronged quality improvement approach to reducing cardiac surgery mortality.

    Science.gov (United States)

    Scheinerman, S Jacob; Dlugacz, Yosef D; Hartman, Alan R; Moravick, Donna; Nelson, Karen L; Scanlon, Kerri Anne; Stier, Lori

    2015-02-01

    In 2006, leadership at Long Island Jewish Medical Center (New Hyde Park, New York) noted significantly higher cardiac surgery mortality rates for isolated valve and valve/coronary artery bypass graft procedures compared to the New York State Department of Health's Cardiac Surgery Reporting System statewide average. Long Island Jewish Medical Center, a 583-bed nonprofit, tertiary care teaching hospital, is one of the clinical and academic hubs of North Shore-LIJ Health System. Senior leadership launched an evaluation of the cardiac surgery program to determine why cardiac surgery mortality rates were higher than expected. As a result, the cardiac surgery program was redesigned, and interventions were implemented related to preoperative care, intraoperative monitoring, postoperative care, and the cardiac surgery quality management program. According to the most recent New York State Department of Health reporting period (2009-2011), Long Island Jewish Medical Center had the lowest risk-adjusted mortality rate in New York State for adult patients undergoing surgeries to repair or replace heart valves and for adult patients in need of valve/coronary artery bypass graft surgery. The medical center has sustained significantly lower mortality rates compared to the statewide average for the past three cardiac surgery reporting periods. Cardiac surgery mortality rates can be significantly reduced and sustained below comparative norms when the organization is committed to clinical excellence and quality and is involved in continuously assessing organizational performance. The evaluation launched at Long Island Jewish Medical Center led to the redesign of the cardiac surgery program and prompted widespread improvement efforts and cultural change across the entire organization.

  7. High performance sapphire windows

    Science.gov (United States)

    Bates, Stephen C.; Liou, Larry

    1993-02-01

    High-quality, wide-aperture optical access is usually required for the advanced laser diagnostics that can now make a wide variety of non-intrusive measurements of combustion processes. Specially processed and mounted sapphire windows are proposed to provide this optical access to extreme environment. Through surface treatments and proper thermal stress design, single crystal sapphire can be a mechanically equivalent replacement for high strength steel. A prototype sapphire window and mounting system have been developed in a successful NASA SBIR Phase 1 project. A large and reliable increase in sapphire design strength (as much as 10x) has been achieved, and the initial specifications necessary for these gains have been defined. Failure testing of small windows has conclusively demonstrated the increased sapphire strength, indicating that a nearly flawless surface polish is the primary cause of strengthening, while an unusual mounting arrangement also significantly contributes to a larger effective strength. Phase 2 work will complete specification and demonstration of these windows, and will fabricate a set for use at NASA. The enhanced capabilities of these high performance sapphire windows will lead to many diagnostic capabilities not previously possible, as well as new applications for sapphire.

  8. Willingness to Perform Chest Compression Only in Witnessed Cardiac Arrest Victims versus Cardiopulmonary Resuscitation in Iran

    Directory of Open Access Journals (Sweden)

    Nesreen Yaghmour

    2015-03-01

    Full Text Available Background: Performing immediate bystander Cardio Pulmonary Resuscitation (CPR is the most important factor that determines survival from cardiac arrest. Recommended mouth to mouth ventilation maneuver during CPR has led to lower rate of CPR performance in the population. Objectives: The present survey aimed to evaluate the willingness of nurses at Shiraz University of Medical Sciences for performing CPR versus chest-compression-only CPR. Patients and Methods: During a CPR course, we performed a survey on 25 nurses from Shiraz University of Medical Sciences, Iran. This survey included age and gender of the participants. In the first question, they were asked about their willingness to perform CPR with mouth to mouth breathing for witnessed cardiac arrest victims. In the second question, they were asked about their willingness to perform chest compression only for cardiac arrest victims. Results: Among the participating nurses, 96% were female with a mean age of 31 years. Only 40% were willing to perform CPR that requires mouth to mouth ventilation. On the other hand, 92% were willing to perform chest compression only without mouth to mouth ventilation. The mean age of the nurses who would do CPR was lower compared to those who would not. Conclusions: In this survey, we demonstrated that eliminating mouth to mouth ventilation maneuver could lead to markedly higher willingness to perform CPR for witnessed cardiac arrest victims in CPR trained nursing personnel. Our study is in agreement with other studies advocating that chest-compression-only CPR could lead to higher bystander resuscitation efforts.

  9. High-Resolution Mapping of Chromatin Conformation in Cardiac Myocytes Reveals Structural Remodeling of the Epigenome in Heart Failure.

    Science.gov (United States)

    Rosa-Garrido, Manuel; Chapski, Douglas J; Schmitt, Anthony D; Kimball, Todd H; Karbassi, Elaheh; Monte, Emma; Balderas, Enrique; Pellegrini, Matteo; Shih, Tsai-Ting; Soehalim, Elizabeth; Liem, David; Ping, Peipei; Galjart, Niels J; Ren, Shuxun; Wang, Yibin; Ren, Bing; Vondriska, Thomas M

    2017-10-24

    Cardiovascular disease is associated with epigenomic changes in the heart; however, the endogenous structure of cardiac myocyte chromatin has never been determined. To investigate the mechanisms of epigenomic function in the heart, genome-wide chromatin conformation capture (Hi-C) and DNA sequencing were performed in adult cardiac myocytes following development of pressure overload-induced hypertrophy. Mice with cardiac-specific deletion of CTCF (a ubiquitous chromatin structural protein) were generated to explore the role of this protein in chromatin structure and cardiac phenotype. Transcriptome analyses by RNA-seq were conducted as a functional readout of the epigenomic structural changes. Depletion of CTCF was sufficient to induce heart failure in mice, and human patients with heart failure receiving mechanical unloading via left ventricular assist devices show increased CTCF abundance. Chromatin structural analyses revealed interactions within the cardiac myocyte genome at 5-kb resolution, enabling examination of intra- and interchromosomal events, and providing a resource for future cardiac epigenomic investigations. Pressure overload or CTCF depletion selectively altered boundary strength between topologically associating domains and A/B compartmentalization, measurements of genome accessibility. Heart failure involved decreased stability of chromatin interactions around disease-causing genes. In addition, pressure overload or CTCF depletion remodeled long-range interactions of cardiac enhancers, resulting in a significant decrease in local chromatin interactions around these functional elements. These findings provide a high-resolution chromatin architecture resource for cardiac epigenomic investigations and demonstrate that global structural remodeling of chromatin underpins heart failure. The newly identified principles of endogenous chromatin structure have key implications for epigenetic therapy. © 2017 The Authors.

  10. Carbon nanotube-incorporated collagen hydrogels improve cell alignment and the performance of cardiac constructs

    Directory of Open Access Journals (Sweden)

    Sun HY

    2017-04-01

    Full Text Available Hongyu Sun,* Jing Zhou,* Zhu Huang,* Linlin Qu,* Ning Lin,* Chengxiao Liang, Ruiwu Dai, Lijun Tang, Fuzhou Tian General Surgery Center, Chengdu Military General Hospital, Chengdu, China *These authors contributed equally to this work Abstract: Carbon nanotubes (CNTs provide an essential 2-D microenvironment for cardiomyocyte growth and function. However, it remains to be elucidated whether CNT nanostructures can promote cell–cell integrity and facilitate the formation of functional tissues in 3-D hydrogels. Here, single-walled CNTs were incorporated into collagen hydrogels to fabricate (CNT/Col hydrogels, which improved mechanical and electrical properties. The incorporation of CNTs (up to 1 wt% exhibited no toxicity to cardiomyocytes and enhanced cell adhesion and elongation. Through the use of immunohistochemical staining, transmission electron microscopy, and intracellular calcium-transient measurement, the incorporation of CNTs was found to improve cell alignment and assembly remarkably, which led to the formation of engineered cardiac tissues with stronger contraction potential. Importantly, cardiac tissues based on CNT/Col hydrogels were noted to have better functionality. Collectively, the incorporation of CNTs into the Col hydrogels improved cell alignment and the performance of cardiac constructs. Our study suggests that CNT/Col hydrogels offer a promising tissue scaffold for cardiac constructs, and might serve as injectable biomaterials to deliver cell or drug molecules for cardiac regeneration following myocardial infarction in the near future. Keywords: carbon nanotubes, collagen hydrogel, cardiac constructs, cell alignment, tissue functionality

  11. A multi-region assessment of population rates of cardiac catheterization and yield of high-risk coronary artery disease

    Directory of Open Access Journals (Sweden)

    Clement Fiona M

    2011-11-01

    Full Text Available Abstract Background There is variation in cardiac catheterization utilization across jurisdictions. Previous work from Alberta, Canada, showed no evidence of a plateau in the yield of high-risk disease at cardiac catheterization rates as high as 600 per 100,000 population suggesting that the optimal rate is higher. This work aims 1 To determine if a previously demonstrated linear relationship between the yield of high-risk coronary disease and cardiac catheterization rates persists with contemporary data and 2 to explore whether the linear relationship exists in other jurisdictions. Methods Detailed clinical information on all patients undergoing cardiac catheterization in 3 Canadian provinces was available through the Alberta Provincial Project for Outcomes Assessment in Coronary Heart (APPROACH disease and partner initiatives in British Columbia and Nova Scotia. Population rates of catheterization and high-risk coronary disease detection for each health region in these three provinces, and age-adjusted rates produced using direct standardization. A mixed effects regression analysis was performed to assess the relationship between catheterization rate and high-risk coronary disease detection. Results In the contemporary Alberta data, we found a linear relationship between the population catheterization rate and the high-risk yield. Although the yield was slightly less in time period 2 (2002-2006 than in time period 1(1995-2001, there was no statistical evidence of a plateau. The linear relationship between catheterization rate and high-risk yield was similarly demonstrated in British Columbia and Nova Scotia and appears to extend, without a plateau in yield, to rates over 800 procedures per 100,000 population. Conclusions Our study demonstrates a consistent finding, over time and across jurisdictions, of linearly increasing detection of high-risk CAD as population rates of cardiac catheterization increase. This internationally-relevant finding

  12. Rapid Rule-Out of Acute Myocardial Injury Using a Single High-Sensitivity Cardiac Troponin I Measurement.

    Science.gov (United States)

    Sandoval, Yader; Smith, Stephen W; Shah, Anoop S V; Anand, Atul; Chapman, Andrew R; Love, Sara A; Schulz, Karen; Cao, Jing; Mills, Nicholas L; Apple, Fred S

    2017-01-01

    Rapid rule-out strategies using high-sensitivity cardiac troponin assays are largely supported by studies performed outside the US in selected cohorts of patients with chest pain that are atypical of US practice, and focused exclusively on ruling out acute myocardial infarction (AMI), rather than acute myocardial injury, which is more common and associated with a poor prognosis. Prospective, observational study of consecutive patients presenting to emergency departments [derivation (n = 1647) and validation (n = 2198) cohorts], where high-sensitivity cardiac troponin I (hs-cTnI) was measured on clinical indication. The negative predictive value (NPV) and diagnostic sensitivity of an hs-cTnI concentration rules out acute myocardial injury, regardless of etiology, with an excellent NPV and diagnostic sensitivity, and identifies patients at minimal risk of AMI or cardiac death at 30 days. ClinicalTrials.gov Identifier: NCT02060760. © 2016 American Association for Clinical Chemistry.

  13. Goal striving strategies and effort mobilization: When implementation intentions reduce effort-related cardiac activity during task performance.

    Science.gov (United States)

    Freydefont, Laure; Gollwitzer, Peter M; Oettingen, Gabriele

    2016-09-01

    Two experiments investigate the influence of goal and implementation intentions on effort mobilization during task performance. Although numerous studies have demonstrated the beneficial effects of setting goals and making plans on performance, the effects of goals and plans on effort-related cardiac activity and especially the cardiac preejection period (PEP) during goal striving have not yet been addressed. According to the Motivational Intensity Theory, participants should increase effort mobilization proportionally to task difficulty as long as success is possible and justified. Forming goals and making plans should allow for reduced effort mobilization when participants perform an easy task. However, when the task is difficult, goals and plans should differ in their effect on effort mobilization. Participants who set goals should disengage, whereas participants who made if-then plans should stay in the field showing high effort mobilization during task performance. As expected, using an easy task in Experiment 1, we observed a lower cardiac PEP in both the implementation intention and the goal intention condition than in the control condition. In Experiment 2, we varied task difficulty and demonstrated that while participants with a mere goal intention disengaged from difficult tasks, participants with an implementation intention increased effort mobilization proportionally with task difficulty. These findings demonstrate the influence of goal striving strategies (i.e., mere goals vs. if-then plans) on effort mobilization during task performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. High Dietary Fat Selectively Increases Catalase Expression within Cardiac Mitochondria*

    Science.gov (United States)

    Rindler, Paul M.; Plafker, Scott M.; Szweda, Luke I.; Kinter, Michael

    2013-01-01

    Obesity is a predictor of diabetes and cardiovascular disease. One consequence of obesity is dyslipidemia characterized by high blood triglycerides. It has been proposed that oxidative stress, driven by utilization of lipids for energy, contributes to these diseases. The effects of oxidative stress are mitigated by an endogenous antioxidant enzyme network, but little is known about its response to high fat utilization. Our experiments used a multiplexed quantitative proteomics method to measure antioxidant enzyme expression in heart tissue in a mouse model of diet-induced obesity. This experiment showed a rapid and specific up-regulation of catalase protein, with subsequent assays showing increases in activity and mRNA. Catalase, traditionally considered a peroxisomal protein, was found to be present in cardiac mitochondria and significantly increased in content and activity during high fat feeding. These data, coupled with the fact that fatty acid oxidation enhances mitochondrial H2O2 production, suggest that a localized catalase increase is needed to consume excessive mitochondrial H2O2 produced by increased fat metabolism. To determine whether the catalase-specific response is a common feature of physiological conditions that increase blood triglycerides and fatty acid oxidation, we measured changes in antioxidant expression in fasted versus fed mice. Indeed, a similar specific catalase increase was observed in mice fasted for 24 h. Our findings suggest a fundamental metabolic process in which catalase expression is regulated to prevent damage while preserving an H2O2-mediated sensing of diet composition that appropriately adjusts insulin sensitivity in the short term as needed to prioritize lipid metabolism for complete utilization. PMID:23204527

  15. R high performance programming

    CERN Document Server

    Lim, Aloysius

    2015-01-01

    This book is for programmers and developers who want to improve the performance of their R programs by making them run faster with large data sets or who are trying to solve a pesky performance problem.

  16. High performance work practices, innovation and performance

    DEFF Research Database (Denmark)

    Jørgensen, Frances; Newton, Cameron; Johnston, Kim

    2013-01-01

    Research spanning nearly 20 years has provided considerable empirical evidence for relationships between High Performance Work Practices (HPWPs) and various measures of performance including increased productivity, improved customer service, and reduced turnover. What stands out from......, and Africa to examine these various questions relating to the HPWP-innovation-performance relationship. Each paper discusses a practice that has been identified in HPWP literature and potential variables that can facilitate or hinder the effects of these practices of innovation- and performance...

  17. Chronic performance of a leadless cardiac pacemaker: 1-year follow-up of the LEADLESS trial

    NARCIS (Netherlands)

    Knops, Reinoud E.; Tjong, Fleur V. Y.; Neuzil, Petr; Sperzel, Johannes; Miller, Marc A.; Petru, Jan; Simon, Jaroslav; Sediva, Lucie; de Groot, Joris R.; Dukkipati, Srinivas R.; Koruth, Jacob S.; Wilde, Arthur A. M.; Kautzner, Josef; Reddy, Vivek Y.

    2015-01-01

    A leadless cardiac pacemaker (LCP) system was recently introduced to overcome lead-related complications of conventional pacing systems. To date, long-term results of an LCP system are unknown. The aim of this study was to assess the complication incidence, electrical performance, and rate response

  18. Cardiac CT

    International Nuclear Information System (INIS)

    Dewey, Marc

    2011-01-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  19. Cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-07-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  20. Carbon nanotube-incorporated collagen hydrogels improve cell alignment and the performance of cardiac constructs

    Science.gov (United States)

    Sun, Hongyu; Zhou, Jing; Huang, Zhu; Qu, Linlin; Lin, Ning; Liang, Chengxiao; Dai, Ruiwu; Tang, Lijun; Tian, Fuzhou

    2017-01-01

    Carbon nanotubes (CNTs) provide an essential 2-D microenvironment for cardiomyocyte growth and function. However, it remains to be elucidated whether CNT nanostructures can promote cell–cell integrity and facilitate the formation of functional tissues in 3-D hydrogels. Here, single-walled CNTs were incorporated into collagen hydrogels to fabricate (CNT/Col) hydrogels, which improved mechanical and electrical properties. The incorporation of CNTs (up to 1 wt%) exhibited no toxicity to cardiomyocytes and enhanced cell adhesion and elongation. Through the use of immunohistochemical staining, transmission electron microscopy, and intracellular calcium-transient measurement, the incorporation of CNTs was found to improve cell alignment and assembly remarkably, which led to the formation of engineered cardiac tissues with stronger contraction potential. Importantly, cardiac tissues based on CNT/Col hydrogels were noted to have better functionality. Collectively, the incorporation of CNTs into the Col hydrogels improved cell alignment and the performance of cardiac constructs. Our study suggests that CNT/Col hydrogels offer a promising tissue scaffold for cardiac constructs, and might serve as injectable biomaterials to deliver cell or drug molecules for cardiac regeneration following myocardial infarction in the near future. PMID:28450785

  1. Python high performance programming

    CERN Document Server

    Lanaro, Gabriele

    2013-01-01

    An exciting, easy-to-follow guide illustrating the techniques to boost the performance of Python code, and their applications with plenty of hands-on examples.If you are a programmer who likes the power and simplicity of Python and would like to use this language for performance-critical applications, this book is ideal for you. All that is required is a basic knowledge of the Python programming language. The book will cover basic and advanced topics so will be great for you whether you are a new or a seasoned Python developer.

  2. High performance germanium MOSFETs

    Energy Technology Data Exchange (ETDEWEB)

    Saraswat, Krishna [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States)]. E-mail: saraswat@stanford.edu; Chui, Chi On [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States); Krishnamohan, Tejas [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States); Kim, Donghyun [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States); Nayfeh, Ammar [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States); Pethe, Abhijit [Department of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States)

    2006-12-15

    Ge is a very promising material as future channel materials for nanoscale MOSFETs due to its high mobility and thus a higher source injection velocity, which translates into higher drive current and smaller gate delay. However, for Ge to become main-stream, surface passivation and heterogeneous integration of crystalline Ge layers on Si must be achieved. We have demonstrated growth of fully relaxed smooth single crystal Ge layers on Si using a novel multi-step growth and hydrogen anneal process without any graded buffer SiGe layer. Surface passivation of Ge has been achieved with its native oxynitride (GeO {sub x}N {sub y} ) and high-permittivity (high-k) metal oxides of Al, Zr and Hf. High mobility MOSFETs have been demonstrated in bulk Ge with high-k gate dielectrics and metal gates. However, due to their smaller bandgap and higher dielectric constant, most high mobility materials suffer from large band-to-band tunneling (BTBT) leakage currents and worse short channel effects. We present novel, Si and Ge based heterostructure MOSFETs, which can significantly reduce the BTBT leakage currents while retaining high channel mobility, making them suitable for scaling into the sub-15 nm regime. Through full band Monte-Carlo, Poisson-Schrodinger and detailed BTBT simulations we show a dramatic reduction in BTBT and excellent electrostatic control of the channel, while maintaining very high drive currents in these highly scaled heterostructure DGFETs. Heterostructure MOSFETs with varying strained-Ge or SiGe thickness, Si cap thickness and Ge percentage were fabricated on bulk Si and SOI substrates. The ultra-thin ({approx}2 nm) strained-Ge channel heterostructure MOSFETs exhibited >4x mobility enhancements over bulk Si devices and >10x BTBT reduction over surface channel strained SiGe devices.

  3. High performance germanium MOSFETs

    International Nuclear Information System (INIS)

    Saraswat, Krishna; Chui, Chi On; Krishnamohan, Tejas; Kim, Donghyun; Nayfeh, Ammar; Pethe, Abhijit

    2006-01-01

    Ge is a very promising material as future channel materials for nanoscale MOSFETs due to its high mobility and thus a higher source injection velocity, which translates into higher drive current and smaller gate delay. However, for Ge to become main-stream, surface passivation and heterogeneous integration of crystalline Ge layers on Si must be achieved. We have demonstrated growth of fully relaxed smooth single crystal Ge layers on Si using a novel multi-step growth and hydrogen anneal process without any graded buffer SiGe layer. Surface passivation of Ge has been achieved with its native oxynitride (GeO x N y ) and high-permittivity (high-k) metal oxides of Al, Zr and Hf. High mobility MOSFETs have been demonstrated in bulk Ge with high-k gate dielectrics and metal gates. However, due to their smaller bandgap and higher dielectric constant, most high mobility materials suffer from large band-to-band tunneling (BTBT) leakage currents and worse short channel effects. We present novel, Si and Ge based heterostructure MOSFETs, which can significantly reduce the BTBT leakage currents while retaining high channel mobility, making them suitable for scaling into the sub-15 nm regime. Through full band Monte-Carlo, Poisson-Schrodinger and detailed BTBT simulations we show a dramatic reduction in BTBT and excellent electrostatic control of the channel, while maintaining very high drive currents in these highly scaled heterostructure DGFETs. Heterostructure MOSFETs with varying strained-Ge or SiGe thickness, Si cap thickness and Ge percentage were fabricated on bulk Si and SOI substrates. The ultra-thin (∼2 nm) strained-Ge channel heterostructure MOSFETs exhibited >4x mobility enhancements over bulk Si devices and >10x BTBT reduction over surface channel strained SiGe devices

  4. High Performance Computing Multicast

    Science.gov (United States)

    2012-02-01

    A History of the Virtual Synchrony Replication Model,” in Replication: Theory and Practice, Charron-Bost, B., Pedone, F., and Schiper, A. (Eds...Performance Computing IP / IPv4 Internet Protocol (version 4.0) IPMC Internet Protocol MultiCast LAN Local Area Network MCMD Dr. Multicast MPI

  5. NGINX high performance

    CERN Document Server

    Sharma, Rahul

    2015-01-01

    System administrators, developers, and engineers looking for ways to achieve maximum performance from NGINX will find this book beneficial. If you are looking for solutions such as how to handle more users from the same system or load your website pages faster, then this is the book for you.

  6. How does pressure overload cause cardiac hypertrophy and dysfunction? High-ouabain affinity cardiac Na+ pumps are crucial.

    Science.gov (United States)

    Blaustein, Mordecai P

    2017-11-01

    Left ventricular hypertrophy is frequently observed in hypertensive patients and is believed to be due to the pressure overload and cardiomyocyte stretch. Three recent reports on mice with genetically engineered Na + pumps, however, have demonstrated that cardiac ouabain-sensitive α 2 -Na + pumps play a key role in the pathogenesis of transaortic constriction-induced hypertrophy. Hypertrophy was delayed/attenuated in mice with mutant, ouabain-resistant α 2 -Na + pumps and in mice with cardiac-selective knockout or transgenic overexpression of α 2 -Na + pumps. The latter, seemingly paradoxical, findings can be explained by comparing the numbers of available (ouabain-free) high-affinity (α 2 ) ouabain-binding sites in wild-type, knockout, and transgenic hearts. Conversely, hypertrophy was accelerated in α 2 -ouabain-resistant (R) mice in which the normally ouabain-resistant α 1 -Na + pumps were mutated to an ouabain-sensitive (S) form (α 1 S/S α 2 R/R or "SWAP" vs. wild-type or α 1 R/R α 2 S/S mice). Furthermore, transaortic constriction-induced hypertrophy in SWAP mice was prevented/reversed by immunoneutralizing circulating endogenous ouabain (EO). These findings show that EO and its receptor, ouabain-sensitive α 2 , are critical factors in pressure overload-induced cardiac hypertrophy. This complements reports linking elevated plasma EO to hypertension, cardiac hypertrophy, and failure in humans and elucidates the underappreciated role of the EO-Na + pump pathway in cardiovascular disease. Copyright © 2017 the American Physiological Society.

  7. High-output cardiac failure secondary to multiple vascular malformations in the liver: case report

    International Nuclear Information System (INIS)

    Spaner, S.; Demeter, S.; Lien, D.; Shapiro, J.; McCarthy, M.; Raymond, G.

    2001-01-01

    High-output cardiac failure is associated with several systemic illnesses, including hyperthyroidism, thiamine deficiency, severe anemia, multiple myeloma, Paget's disease of bone and Osler-Weber-Rendu syndrome. We present an unusual case of a woman with high-output cardiac failure as a result of multiple arteriovenous fistulas in the liver, most likely representing an unusual variant of Osler-Weber-Rendu syndrome (i.e., no other telangiectasias or a family history of vascular malformations was demonstrated). (author)

  8. The role of adrenaline as a modulator of cardiac performance in three Notothenioid fishes

    DEFF Research Database (Denmark)

    Skov, Peter Vilhelm; Bushnell, P.; Tirsgaard, Bjørn

    2008-01-01

    The present work was performed to test the hypothesis that Antarctic teleosts rely mostly on cholinergic inhibition to modulate cardiac performance. Isometric muscle preparations were used to examine the inotropic and chronotropic properties of the ventricle and atrium in three Antarctic teleosts...... adrenaline appear to enhance force of contraction for atrial muscle. The study finds that adrenaline modulates ventricular inotropic properties in all species. For Notothenia coriiceps the regulation of power production purely by adrenergic stimulation appeared most beneficial, while for N. microlepidota...

  9. Improved radiation protection for physicians performing cardiac catheterization

    International Nuclear Information System (INIS)

    Gertz, E.W.; Wisneski, J.A.; Gould, R.G.; Akin, J.R.

    1982-01-01

    Physicians and their assistants performing diagnostic angiography must be concerned with the radiation exposure they receive. The introduction of hemiaxial projections for imaging has increased diagnostic accuracy but has also greatly increased the physicians' exposure to scattered radiation. This increase is especially critical for the eyes and thyroid of the physician who routinely performs these procedures. To reduce such exposure a ceiling-suspended shield (60 x 45 cm), made of 6.4 mm glass with a 19.5 kg/m2 (4 lb/ft2) lead equivalency, was developed. During procedures the shield is interposed between the physician and the region of the patient acting as the source of scattered radiation. The degree of radiation protection to the operator was assessed by measuring the distribution of scattered radiation in the vicinity of the operator with and without the shield. The effectiveness of the shield was determined in the 30 degrees right anterior oblique (RAO), 5 degrees left anterior oblique (LAO), 35 degrees LAO, and 50 degrees LAO-15 degrees cranial angulations. At critical heights such as the level of the eyes and thyroid, scattered radiation levels were reduced by 85% or greater in all angulations. Without interfering with the physician's ability to observe the patient or manipulate the catheter, this shield can significantly reduce the physician's exposure to radiation

  10. Performance of the European System for Cardiac Operative Risk Evaluation II: a meta-analysis of 22 studies involving 145,592 cardiac surgery procedures.

    Science.gov (United States)

    Guida, Pietro; Mastro, Florinda; Scrascia, Giuseppe; Whitlock, Richard; Paparella, Domenico

    2014-12-01

    A systematic review of the European System for Cardiac Operative Risk Evaluation (euroSCORE) II performance for prediction of operative mortality after cardiac surgery has not been performed. We conducted a meta-analysis of studies based on the predictive accuracy of the euroSCORE II. We searched the Embase and PubMed databases for all English-only articles reporting performance characteristics of the euroSCORE II. The area under the receiver operating characteristic curve, the observed/expected mortality ratio, and observed-expected mortality difference with their 95% confidence intervals were analyzed. Twenty-two articles were selected, including 145,592 procedures. Operative mortality occurred in 4293 (2.95%), whereas the expected events according to euroSCORE II were 4802 (3.30%). Meta-analysis of these studies provided an area under the receiver operating characteristic curve of 0.792 (95% confidence interval, 0.773-0.811), an estimated observed/expected ratio of 1.019 (95% confidence interval, 0.899-1.139), and observed-expected difference of 0.125 (95% confidence interval, -0.269 to 0.519). Statistical heterogeneity was detected among retrospective studies including less recent procedures. Subgroups analysis confirmed the robustness of combined estimates for isolated valve procedures and those combined with revascularization surgery. A significant overestimation of the euroSCORE II with an observed/expected ratio of 0.829 (95% confidence interval, 0.677-0.982) was observed in isolated coronary artery bypass grafting and a slight underestimation of predictions in high-risk patients (observed/expected ratio 1.253 and observed-expected difference 1.859). Despite the heterogeneity, the results from this meta-analysis show a good overall performance of the euroSCORE II in terms of discrimination and accuracy of model predictions for operative mortality. Validation of the euroSCORE II in prospective populations needs to be further studied for a continuous

  11. High performance proton accelerators

    International Nuclear Information System (INIS)

    Favale, A.J.

    1989-01-01

    In concert with this theme this paper briefly outlines how Grumman, over the past 4 years, has evolved from a company that designed and fabricated a Radio Frequency Quadrupole (RFQ) accelerator from the Los Alamos National Laboratory (LANL) physics and specifications to a company who, as prime contractor, is designing, fabricating, assembling and commissioning the US Army Strategic Defense Commands (USA SDC) Continuous Wave Deuterium Demonstrator (CWDD) accelerator as a turn-key operation. In the case of the RFQ, LANL scientists performed the physics analysis, established the specifications supported Grumman on the mechanical design, conducted the RFQ tuning and tested the RFQ at their laboratory. For the CWDD Program Grumman has the responsibility for the physics and engineering designs, assembly, testing and commissioning albeit with the support of consultants from LANL, Lawrence Berkeley Laboratory (LBL) and Brookhaven National laboratory. In addition, Culham Laboratory and LANL are team members on CWDD. LANL scientists have reviewed the physics design as well as a USA SDC review board. 9 figs

  12. Deep breathing exercises performed 2 months following cardiac surgery: a randomized controlled trial.

    Science.gov (United States)

    Westerdahl, Elisabeth; Urell, Charlotte; Jonsson, Marcus; Bryngelsson, Ing-Liss; Hedenström, Hans; Emtner, Margareta

    2014-01-01

    Postoperative breathing exercises are recommended to cardiac surgery patients. Instructions concerning how long patients should continue exercises after discharge vary, and the significance of treatment needs to be determined. Our aim was to assess the effects of home-based deep breathing exercises performed with a positive expiratory pressure device for 2 months following cardiac surgery. The study design was a prospective, single-blinded, parallel-group, randomized trial. Patients performing breathing exercises 2 months after cardiac surgery (n = 159) were compared with a control group (n = 154) performing no breathing exercises after discharge. The intervention consisted of 30 slow deep breaths performed with a positive expiratory pressure device (10-15 cm H2O), 5 times a day, during the first 2 months after surgery. The outcomes were lung function measurements, oxygen saturation, thoracic excursion mobility, subjective perception of breathing and pain, patient-perceived quality of recovery (40-Item Quality of Recovery score), health-related quality of life (36-Item Short Form Health Survey), and self-reported respiratory tract infection/pneumonia and antibiotic treatment. Two months postoperatively, the patients had significantly reduced lung function, with a mean decrease in forced expiratory volume in 1 second to 93 ± 12% (P< .001) of preoperative values. Oxygenation had returned to preoperative values, and 5 of 8 aspects in the 36-Item Short Form Health Survey were improved compared with preoperative values (P< .01). There were no significant differences between the groups in any of the measured outcomes. No significant differences in lung function, subjective perceptions, or quality of life were found between patients performing home-based deep breathing exercises and control patients 2 months after cardiac surgery.

  13. The cognitive basis of effective team performance: features of failure and success in simulated cardiac resuscitation.

    Science.gov (United States)

    Shetty, Pallavi; Cohen, Trevor; Patel, Bhavesh; Patel, Vimla L

    2009-11-14

    Despite a body of research on teams in other fields relatively little is known about measuring teamwork in healthcare. The aim of this study is to characterize the qualitative dimensions of team performance during cardiac resuscitation that results in good and bad outcomes. We studied each team's adherence to Advanced Cardiac Life Support (ACLS) protocol for ventricular fibrillation/tachycardia and identified team behaviors during simulated critical events that affected their performance. The process was captured by a developed task checklist and a validated team work coding system. Results suggest that deviation from the sequence suggested by the ACLS protocol had no impact on the outcome as the successful team deviated more from this sequence than the unsuccessful team. It isn't the deviation from the protocol per se that appears to be important, but how the leadership flexibly adapts to the situational changes with deviations is the crucial factor in team competency.

  14. A high-sugar and high-fat diet impairs cardiac systolic and diastolic function in mice.

    Science.gov (United States)

    Carbone, Salvatore; Mauro, Adolfo G; Mezzaroma, Eleonora; Kraskauskas, Donatas; Marchetti, Carlo; Buzzetti, Raffaella; Van Tassell, Benjamin W; Abbate, Antonio; Toldo, Stefano

    2015-11-01

    Heart failure (HF) is a clinical syndrome characterized by dyspnea, fatigue, exercise intolerance and cardiac dysfunction. Unhealthy diet has been associated with increased risk of obesity and heart disease, but whether it directly affects cardiac function, and promotes the development and progression of HF is unknown. We fed 8-week old male or female CD-1 mice with a standard diet (SD) or a diet rich in saturated fat and sugar, resembling a "Western" diet (WD). Cardiac systolic and diastolic function was measured at baseline and 4 and 8 weeks by Doppler echocardiography, and left ventricular (LV) end-diastolic pressure (EDP) by cardiac catheterization prior to sacrifice. An additional group of mice received WD for 4 weeks followed by SD (wash-out) for 8 weeks. WD-fed mice experienced a significant decreased in LV ejection fraction (LVEF), reflecting impaired systolic function, and a significant increase in isovolumetric relaxation time (IRT), myocardial performance index (MPI), and LVEDP, showing impaired diastolic function, without any sex-related differences. Switching to a SD after 4 weeks of WD partially reversed the cardiac systolic and diastolic dysfunction. A diet rich in saturated fat and sugars (WD) impairs cardiac systolic and diastolic function in the mouse. Further studies are required to define the mechanism through which diet affects cardiac function, and whether dietary interventions can be used in patients with, or at risk for, HF. Published by Elsevier Ireland Ltd.

  15. Developmental changes in in vivo cardiac performance in the moth Manduca sexta.

    Science.gov (United States)

    Smits, A W; Burggren, W W; Oliveras, D

    2000-01-01

    While an extensive literature on cardiovascular development exists for insects, almost all studies focus on in vitro preparations, and very few report on more than a single developmental stage. The present study examines in vivo cardiac performance in the intact, unanesthetized larvae, pupae and adults of the tobacco hornworm Manduca sexta. For all three stages, electrode pairs of fine steel wire were inserted subcuticularly at two dorsal abdominal locations. Impedance signals produced by contraction of the dorsal abdominal vessel (tube heart) were amplified and recorded. In addition to providing heart rate, a comparison of the relative timing of the signal from each electrode pair allowed the calculation of the propagation velocity and direction of heart contraction. Experimental treatments of intact animals included exposure to hypoxia and hyperoxia (21 %, 15 %, 10 %, 5 %, 0 % and 100 % O(2)), to hypercapnia (0 %, 4 %, 8 %, 16 %, 20 % and 24 % CO(2)), to temperature variation (10, 20 and 30 degrees C) and to 2 min periods of forced activity. The pattern of contraction of the dorsal abdominal vessel of M. sexta changed substantially with developmental stage. Larvae showed a relatively simple, invariably posterior-to-anterior pattern (mean rate 34.8+/-1.16 beats min(-)(1)). The heart rate pattern in pupal M. sexta displayed great variability in rate, amplitude and direction. Periods of regular heart beats (21.5+/-1.09 beats min(-)(1)) were frequently and irregularly interrupted by periods of cardiac arrests ranging from a few seconds to over 20 min. Adults showed a highly stereotypic but complex pattern, with periods of 'fast forward' (FF; rate 47.6+/-2.6 beats min(-)(1)), 'slow forward' (SL; 32.8+/-3.0 beats min(-)(1)) and 'reversed' (R; 32.2+/-2.4 beats min(-)(1)) beating. The contraction propagation velocity in larvae and pupae averaged 5. 52+/-0.36 and 2.03+/-0.11 cm s(-)(1), respectively. The SF, R and FF phases of the adults had average propagation velocities

  16. Improved performance of maternal-fetal medicine staff after maternal cardiac arrest simulation-based training.

    Science.gov (United States)

    Fisher, Nelli; Eisen, Lewis A; Bayya, Jyothshna V; Dulu, Alina; Bernstein, Peter S; Merkatz, Irwin R; Goffman, Dena

    2011-09-01

    To determine the impact of simulation-based maternal cardiac arrest training on performance, knowledge, and confidence among Maternal-Fetal Medicine staff. Maternal-Fetal Medicine staff (n = 19) participated in a maternal arrest simulation program. Based on evaluation of performance during initial simulations, an intervention was designed including: basic life support course, advanced cardiac life support pregnancy modification lecture, and simulation practice. Postintervention evaluative simulations were performed. All simulations included a knowledge test, confidence survey, and debriefing. A checklist with 9 pregnancy modification (maternal) and 16 critical care (25 total) tasks was used for scoring. Postintervention scores reflected statistically significant improvement. Maternal-Fetal Medicine staff demonstrated statistically significant improvement in timely initiation of cardiopulmonary resuscitation (120 vs 32 seconds, P = .042) and cesarean delivery (240 vs 159 seconds, P = .017). Prompt cardiopulmonary resuscitation initiation and pregnancy modifications application are critical in maternal and fetal survival during cardiac arrest. Simulation is a useful tool for Maternal-Fetal Medicine staff to improve skills, knowledge, and confidence in the management of this catastrophic event. Published by Mosby, Inc.

  17. What Limits Cardiac Performance during Exercise in Normal Subjects and in Healthy Fontan Patients?

    Directory of Open Access Journals (Sweden)

    André La Gerche

    2010-01-01

    Full Text Available Exercise is an important determinant of health but is significantly reduced in the patient with a univentricular circulation. Normal exercise physiology mandates an increase in pulmonary artery pressures which places an increased work demand on the right ventricle (RV. In a biventricular circulation with pathological increases in pulmonary vascular resistance and/or reductions in RV function, exercise-induced augmentation of cardiac output is limited. Left ventricular preload reserve is dependent upon flow through the pulmonary circulation and this requires adequate RV performance. In the Fontan patient, the reasons for exercise intolerance are complex. In those patients with myocardial dysfunction or other pathologies of the circulatory components, it is likely that these abnormalities serve as a limitation to cardiac performance during exercise. However, in the healthy Fontan patient, it may be the absence of a sub-pulmonary pump which limits normal increases in pulmonary pressures, trans-pulmonary flow requirements and cardiac output. If so, performance will be exquisitely dependent on pulmonary vascular resistance. This provides a potential explanation as to why pulmonary vasodilators may improve exercise tolerance. As has recently been demonstrated, these agents may offer an important new treatment strategy which directly addresses the physiological limitations in the Fontan patient.

  18. Frequency of cardiac arrhythmias in high and low- yielding dairy cows

    Directory of Open Access Journals (Sweden)

    Afshin Jafari Dehkordi

    2014-06-01

    Full Text Available Electrocardiography (ECG may be used to recognize cardiac disorders. Levels of milk production may change the serum electrolytes which its imbalance has a role in cardiac arrhythmia. Fifty high yielding and fifty low yielding Holstein dairy cows were used in this study. Electrocardiography was recorded by base-apex lead and blood samples were collected from jugular vein for measurement of serum elements such as sodium, potassium, calcium, phosphorous, iron and magnesium. Cardiac dysrhythmias were detected more frequent in low yielding Holstein cows (62.00% compared to high yielding Holstein cows (46.00%. The cardiac dysrhythmias that were observed in low yielding Holstein cows included sinus arrhythmia (34.70%, wandering pacemaker (22.45 %, bradycardia (18.37%, tachycardia (10.20%, atrial premature beat (2.04%, sinoatrial block (2.04%, atrial fibrillation (8.16% and atrial tachycardia (2.04%. The cardiac dysrhythmias were observed in high yielding Holstein cows including, sinus arrhythmia (86.95% and wandering pacemaker (13.05%. Also, notched P wave was observed to be 30% and 14% in high- and low- yielding Holstein cows respectively. The serum calcium concentration of low yielding Holstein cows was significantly lower than that of high yielding Holstein cows. There was not any detectable significant difference in other serum elements between high- and low- yielding Holstein cows. Based on the result of present study, could be concluded that low serum concentration of calcium results to more frequent dysrhythmias in low yielding Holstein cows.

  19. Is Baseline Cardiac Autonomic Modulation Related to Performance and Physiological Responses Following a Supramaximal Judo Test?

    Science.gov (United States)

    Blasco-Lafarga, Cristina; Martínez-Navarro, Ignacio; Mateo-March, Manuel

    2013-01-01

    Little research exists concerning Heart Rate (HR) Variability (HRV) following supramaximal efforts focused on upper-body explosive strength-endurance. Since they may be very demanding, it seems of interest to analyse the relationship among performance, lactate and HR dynamics (i.e. HR, HRV and complexity) following them; as well as to know how baseline cardiac autonomic modulation mediates these relationships. The present study aimed to analyse associations between baseline and post-exercise HR dynamics following a supramaximal Judo test, and their relationship with lactate, in a sample of 22 highly-trained male judoists (20.70±4.56 years). A large association between the increase in HR from resting to exercise condition and performance suggests that individuals exerted a greater sympathetic response to achieve a better performance (Rating of Perceived Exertion: 20; post-exercise peak lactate: 11.57±2.24 mmol/L; 95.76±4.13 % of age-predicted HRmax). Athletes with higher vagal modulation and lower sympathetic modulation at rest achieved both a significant larger ∆HR and a faster post-exercise lactate removal. A enhanced resting parasympathetic modulation might be therefore related to a further usage of autonomic resources and a better immediate metabolic recovery during supramaximal exertions. Furthermore, analyses of variance displayed a persistent increase in α1 and a decrease in lnRMSSD along the 15 min of recovery, which are indicative of a diminished vagal modulation together with a sympathovagal balance leaning to sympathetic domination. Eventually, time-domain indices (lnRMSSD) showed no lactate correlations, while nonlinear indices (α1 and lnSaEn) appeared to be moderate to strongly correlated with it, thus pointing to shared mechanisms between neuroautonomic and metabolic regulation. PMID:24205273

  20. Assessment Of Nurses Performance During Cardiopulmonary Resuscitation In Intensive Care Unit And Cardiac Care Unit At The Alexandria Main University Hospital.

    Directory of Open Access Journals (Sweden)

    Dr. Nagla Hamdi Kamal Khalil El- Meanawi

    2015-08-01

    Full Text Available Abstract Background Cardiopulmonary resuscitation one of the most emergency management the nurse has a pivotal role and should be highly qualified in performing these procedures. The aim of the study is to assess performance of nurses during Cardio pulmonary resuscitation for patient with cardiac arrest In Intensive Care Unit and Cardiac Care Unit at the Alexandria main university hospital. To answer the question what are the most common area of satisfactory and area of neglection in nurses performance during Cardio Pulmonary Resuscitation. The sample consists of 53 staff nurses working in Intensive care unit amp cardiac care unit at Alexandria main university hospital. The tools of data collection were structured of questionnaire sheet and observational cheek list. The results showed that unsatisfactory performance between nurses in both units. The study concluded that all nurses need to improve their performance during cardiopulmonary resuscitation for patient with cardiac arrest it is crucial for nursing staff to participate in CPR courses in order to refresh and update their theoretical knowledge and performance skills and consequently to improve the safety and effectiveness of care. The study recommended that continuous evaluation of nurses knowledge and performance is essential the optimal frequency with which CPR training should be implemented at least every 6 months in order to avoid deterioration in nurses CPR knowledge and skills.

  1. High-velocity penetrating thoracic trauma with suspected cardiac involvement in a combat support hospital

    International Nuclear Information System (INIS)

    Dominguez, F.; Gentlesk, P.J.; Eckart, R.E.; Beekley, A.C.; Huffer, L.L.

    2011-01-01

    The most common cardiac injuries in the United States are blunt trauma from motor vehicle accidents or low-velocity trauma from stabbings. During military conflict, high-velocity injuries, including gunshot wounds (GSW) and fragment injury from improvised explosive devices (IED), are relatively more common. This is a retrospective review of cases with high-velocity penetrating injury and suspected myocardial involvement during a 6-month period in Baghdad, Iraq, at a United States Army hospital during Operation Iraqi Freedom. Eleven cases survived to admission (GSW in 5, IED in 6). The mean age of the all-male cohort was 27 years (range, 3-54 years). Eight of the 11 patients (73%) were victims of polytrauma. The entrance involved the right ventricle (n=3), right atrium (n=2), left ventricle (n=1), or mediastinum and pericardial reflections (n=5). Echocardiography was performed in all 11 patients. In 7 patients, no foreign body was identifiable, and in 2 patients the foreign body was identified within the pericardial fat pad. Three patients were identified as having a suspected ventricular septal defect, ranging in size from 2 to 8 mm. The most common electrocardiographic abnormality was atrioventricular block and right bundle branch block. In 4 patients, the management of the chest injury was nonsurgical, and in 1 patient the treatment was a chest tube only. Four of the patients underwent median sternotomy, 1 underwent emergent lateral thoracotomy, and 1 underwent an infradiaphragmatic approach. This case series is too small to draw definitive conclusions; however, a multidisciplinary approach to high-velocity injuries with potential for cardiac involvement augments preoperative assessment for myocardial injury and may allow selective nonoperative management. (author)

  2. High Performance Networks for High Impact Science

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Mary A.; Bair, Raymond A.

    2003-02-13

    This workshop was the first major activity in developing a strategic plan for high-performance networking in the Office of Science. Held August 13 through 15, 2002, it brought together a selection of end users, especially representing the emerging, high-visibility initiatives, and network visionaries to identify opportunities and begin defining the path forward.

  3. Evidence of direct cardiac damage following high-intensity exercise in chronic energy restriction: A case report and literature review.

    Science.gov (United States)

    Baird, Marianne F; Grace, Fergal; Sculthorpe, Nicholas; Graham, Scott M; Fleming, Audrey; Baker, Julien S

    2017-07-01

    Following prolonged endurance events such as marathons, elevated levels of cardiospecific biomarkers are commonly reported. Although transiently raised levels are generally not considered to indicate clinical myocardial damage, comprehension of this phenomenon remains incomplete. The popularity of high-intensity interval training highlights a paucity of research measuring cardiac biomarker response to this type of exercise. This a posteriori case report discusses the elevation of cardiac troponins (cTn) associated with short interval, high-intensity exercise. In this case report, an apparently healthy 29-year-old recreationally active female presented clinically raised cardiac troponin I (cTnI) levels (>0.04 ng/mL), after performing high-intensity cycle ergometer sprints. As creatine kinase (CK) is expressed by multiple organs (e.g., skeletal muscle, brain, and myocardium), cTnI assays were performed to determine any changes in total serum CK levels not originating from skeletal muscle damage. A posteriori the individual's daily energy expenditure indicated chronically low-energy availability. Psychometric testing suggested that the individual scored positive for disordered eating, highly for fatigue levels, and low in mental health components. The current case report provides novel evidence of elevated cTnI occurring as a result of performing short duration, high intensity, cycle ergometer exercise in an individual with self-reported chronically depleted energy balance. A schematic to identify potentially "at risk" individuals is presented. Considering this as a case report, results cannot be generalized; however, the main findings suggest that individuals who habitually restrict their calorie intake below their bodies' daily energy requirements, may have elevated biomarkers of exercise induced myocardial stress from performing high-intensity exercise.

  4. End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system

    International Nuclear Information System (INIS)

    Chan, Chung; Sinusas, Albert J; Liu, Chi; Harris, Mark; Le, Max; Biondi, James; Grobshtein, Yariv; Liu, Yi-Hwa

    2014-01-01

    Respiratory and cardiac motions can degrade myocardial perfusion SPECT (MPS) image quality and reduce defect detection and quantitative accuracy. In this study, we developed a dual respiratory and cardiac gating system for a high-resolution fully stationary cardiac SPECT scanner in order to improve the image quality and defect detection. Respiratory motion was monitored using a compressive sensor pillow connected to a dual respiratory–cardiac gating box, which sends cardiac triggers only during end-expiration phases to the single cardiac trigger input on the SPECT scanners. The listmode data were rebinned retrospectively into end-expiration frames for respiratory motion reduction or eight cardiac gates only during end-expiration phases to compensate for both respiratory and cardiac motions. The proposed method was first validated on a motion phantom in the presence and absence of multiple perfusion defects, and then applied on 11 patient studies with and without perfusion defects. In the normal phantom studies, the end-expiration gated SPECT (EXG-SPECT) reduced respiratory motion blur and increased myocardium to blood pool contrast by 51.2% as compared to the ungated images. The proposed method also yielded an average of 11.2% increase in myocardium to defect contrast as compared to the ungated images in the phantom studies with perfusion defects. In the patient studies, EXG-SPECT significantly improved the myocardium to blood pool contrast (p < 0.005) by 24% on average as compared to the ungated images, and led to improved perfusion uniformity across segments on polar maps for normal patients. For a patient with defect, EXG-SPECT improved the defect contrast and definition. The dual respiratory–cardiac gating further reduced the blurring effect, increased the myocardium to blood pool contrast significantly by 36% (p < 0.05) compared to EXG-SPECT, and further improved defect characteristics and visualization of fine structures at the expense of increased

  5. A systematic review of basic life support training targeted to family members of high-risk cardiac patients.

    Science.gov (United States)

    Cartledge, Susie; Bray, Janet E; Leary, Marion; Stub, Dion; Finn, Judith

    2016-08-01

    Targeting basic life support (BLS) training to bystanders who are most likely to witness an out of hospital cardiac arrest (OHCA) is an important public health intervention. We performed a systematic review examining the evidence of the effectiveness of providing BLS training to family members of high-risk cardiac patients. A search of Ovid MEDLINE, CINAL, EMBASE, Informit, Cochrane Library, Web of Science, Scopus, ERIC and ProQuest Dissertations and Theses Global was conducted. We included all studies training adult family members of high-risk cardiac patients regardless of methods used for cardiopulmonary resuscitation (CPR) or BLS training. Two reviewers independently extracted data and evaluated the quality of evidence using GRADE (Grades of Recommendation, Assessment, Development and Evaluation). We included 26 of the 1172 studies identified. The majority of studies were non-randomised controlled trials (n=18), of very low to moderate quality. Currently, there is insufficient evidence to indicate a benefit of this intervention for patients; largely because of low numbers of OHCA events and high loss to follow-up. However, the majority of trained individuals were able to competently perform BLS skills, reported a willingness to use these skills and experienced lower anxiety. Whilst there is no current evidence for improvement in patient outcomes from targeted BLS training for family members, this group are willing and capable to learn these skills. Future research may need to examine longer periods of follow-up using alternate methods (e.g. cardiac arrest registries), and examine the effectiveness of training in the modern era. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. RavenDB high performance

    CERN Document Server

    Ritchie, Brian

    2013-01-01

    RavenDB High Performance is comprehensive yet concise tutorial that developers can use to.This book is for developers & software architects who are designing systems in order to achieve high performance right from the start. A basic understanding of RavenDB is recommended, but not required. While the book focuses on advanced topics, it does not assume that the reader has a great deal of prior knowledge of working with RavenDB.

  7. Combining High Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction.

    Science.gov (United States)

    van der Linden, Noreen; Wildi, Karin; Twerenbold, Raphael; Pickering, John W; Than, Martin; Cullen, Louise; Greenslade, Jaimi; Parsonage, William; Nestelberger, Thomas; Boeddinghaus, Jasper; Badertscher, Patrick; Rubini Giménez, Maria; Klinkenberg, Lieke J J; Bekers, Otto; Schöni, Aline; Keller, Dagmar I; Sabti, Zaid; Puelacher, Christian; Cupa, Janosch; Schumacher, Lukas; Kozhuharov, Nikola; Grimm, Karin; Shrestha, Samyut; Flores, Dayana; Freese, Michael; Stelzig, Claudia; Strebel, Ivo; Miró, Òscar; Rentsch, Katharina; Morawiec, Beata; Kawecki, Damian; Kloos, Wanda; Lohrmann, Jens; Richards, A Mark; Troughton, Richard; Pemberton, Christopher; Osswald, Stefan; van Dieijen-Visser, Marja P; Mingels, Alma M; Reichlin, Tobias; Meex, Steven J R; Mueller, Christian

    2018-04-24

    Background -Combining two signals of cardiomyocyte injury, cardiac troponin I (cTnI) and T (cTnT), might overcome some individual pathophysiological and analytical limitations and thereby increase diagnostic accuracy for acute myocardial infarction (AMI) with a single blood draw. We aimed to evaluate the diagnostic performance of combinations of high sensitivity (hs) cTnI and hs-cTnT for the early diagnosis of AMI. Methods -The diagnostic performance of combining hs-cTnI (Architect, Abbott) and hs-cTnT (Elecsys, Roche) concentrations (sum, product, ratio and a combination algorithm) obtained at the time of presentation was evaluated in a large multicenter diagnostic study of patients with suspected AMI. The optimal rule out and rule in thresholds were externally validated in a second large multicenter diagnostic study. The proportion of patients eligible for early rule out was compared with the ESC 0/1 and 0/3 hour algorithms. Results -Combining hs-cTnI and hs-cTnT concentrations did not consistently increase overall diagnostic accuracy as compared with the individual isoforms. However, the combination improved the proportion of patients meeting criteria for very early rule-out. With the ESC 2015 guideline recommended algorithms and cut-offs, the proportion meeting rule out criteria after the baseline blood sampling was limited (6-24%) and assay dependent. Application of optimized cut-off values using the sum (9 ng/L) and product (18 ng2/L2) of hs-cTnI and hs-cTnT concentrations led to an increase in the proportion ruled-out after a single blood draw to 34-41% in the original (sum: negative predictive value (NPV) 100% (95%CI: 99.5-100%); product: NPV 100% (95%CI: 99.5-100%) and in the validation cohort (sum: NPV 99.6% (95%CI: 99.0-99.9%); product: NPV 99.4% (95%CI: 98.8-99.8%). The use of a combination algorithm (hs-cTnI <4 ng/L and hs-cTnT <9 ng/L) showed comparable results for rule out (40-43% ruled out; NPV original cohort 99.9% (95%CI: 99.2-100%); NPV

  8. High-Performance Operating Systems

    DEFF Research Database (Denmark)

    Sharp, Robin

    1999-01-01

    Notes prepared for the DTU course 49421 "High Performance Operating Systems". The notes deal with quantitative and qualitative techniques for use in the design and evaluation of operating systems in computer systems for which performance is an important parameter, such as real-time applications......, communication systems and multimedia systems....

  9. Effect of overreaching on cognitive performance and related cardiac autonomic control.

    Science.gov (United States)

    Dupuy, O; Lussier, M; Fraser, S; Bherer, L; Audiffren, M; Bosquet, L

    2014-02-01

    The purpose of this study was to characterize the effect of a 2-week overload period immediately followed by a 1-week taper period on different cognitive processes including executive and nonexecutive functions, and related heart rate variability. Eleven male endurance athletes increased their usual training volume by 100% for 2 weeks, and decreased it by 50% for 1 week. A maximal graded test, a constant speed test at 85% of peak treadmill speed, and a Stroop task with the measurement of heart rate variability were performed at each period. All participants were considered as overreached. We found a moderate increase in the overall reaction time to the three conditions of the Stroop task after the overload period (816 ± 83 vs 892 ± 117 ms, P = 0.03) followed by a return to baseline after the taper period (820 ± 119 ms, P = 0.013). We found no association between cognitive performance and cardiac parasympathetic control at baseline, and no association between changes in these measures. Our findings clearly underscore the relevance of cognitive performance in the monitoring of overreaching in endurance athletes. However, contrary to our hypothesis, we did not find any relationship between executive performance and cardiac parasympathetic control. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Later Onset Fabry Disease, Cardiac Damage Progress in Silence: Experience With a Highly Prevalent Mutation.

    Science.gov (United States)

    Hsu, Ting-Rong; Hung, Sheng-Che; Chang, Fu-Pang; Yu, Wen-Chung; Sung, Shih-Hsien; Hsu, Chia-Lin; Dzhagalov, Ivan; Yang, Chia-Feng; Chu, Tzu-Hung; Lee, Han-Jui; Lu, Yung-Hsiu; Chang, Sheng-Kai; Liao, Hsuan-Chieh; Lin, Hsiang-Yu; Liao, Tsan-Chieh; Lee, Pi-Chang; Li, Hsing-Yuan; Yang, An-Hang; Ho, Hui-Chen; Chiang, Chuan-Chi; Lin, Ching-Yuang; Desnick, Robert J; Niu, Dau-Ming

    2016-12-13

    Recently, several studies revealed a much higher prevalence of later onset Fabry disease (FD) than previously expected. It suggested that later onset FD might present as an important hidden health issue in certain ethnic or demographic populations in the world. However, the natural history of its phenotype has not been systemically investigated, especially the cardiac involvement. The study analyzed a large-scale newborn screening program for FD to understand the natural course of later onset FD. To date, 916,383 newborns have been screened for FD in Taiwan, including more than 1,200 individuals with the common, later onset IVS4+919G>A (IVS4) mutation. Echocardiography was performed in 620 adults with the IVS4 mutation to analyze the prevalence of left ventricular hypertrophy (LVH), and gadolinium-enhanced cardiac magnetic resonance imaging was performed in 129 patients with FD, including 100 IVS4 adults. LVH was observed in 67% of men and 32% of women older than 40 years. Imaging evidenced significant late gadolinium enhancement in 38.1% of IVS4 men and 16.7% of IVS4 women with the IVS4 mutation but without LVH. Seventeen patients underwent endomyocardial biopsies, which revealed significant globotriaosylceramide substrate accumulation in their cardiomyocytes. Significant cardiomyocyte substrate accumulation in IVS4 patients led to severe and irreversible cardiac fibrosis before development of LVH or other significant cardiac manifestations. Thus, it might be too late to start enzyme replacement therapy after the occurrence of LVH or other significant cardiac manifestations in patients with later onset FD. This study also indicated the importance of newborn screening for early detection of the insidious, ongoing, irreversible cardiac damage in patients with later onset FD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Prognostic Value of High-Sensitivity Cardiac Troponin T Compared with Risk Scores in Stable Cardiovascular Disease.

    Science.gov (United States)

    Biener, Moritz; Giannitsis, Evangelos; Kuhner, Manuel; Zelniker, Thomas; Mueller-Hennessen, Matthias; Vafaie, Mehrshad; Trenk, Dietmar; Neumann, Franz-Josef; Hochholzer, Willibald; Katus, Hugo A

    2017-05-01

    Risk stratification of patients with cardiovascular disease remains challenging despite consideration of risk scores. We aimed to evaluate the prognostic performance of high-sensitivity cardiac troponin T in a low-risk outpatient population presenting for nonsecondary and secondary prevention. All-cause mortality, a composite of all-cause mortality, acute myocardial infarction, and stroke (end point 2), and a composite of all-cause mortality, acute myocardial infarction, stroke and rehospitalization for acute coronary syndrome, and decompensated heart failure (end point 3) were defined. The prognostic performance of high-sensitivity cardiac troponin T on index visit was compared with the PROCAM score and 3 FRAMINGHAM subscores. In 693 patients with a median follow-up of 796 days, we observed 16 deaths, 32 patients with end point 2, and 83 patients with end point 3. All risk scores performed better in the prediction of all-cause mortality in nonsecondary prevention (area under the curve [AUC]: PROCAM: 0.922 vs 0.523, P = .001, consistent for all other scores). In secondary prevention, high-sensitivity cardiac troponin T outperformed all risk scores in the prediction of all-cause mortality (ΔAUC: PROCAM: 0.319, P risk scores. Our findings on the prediction of all-cause mortality compared with the FRAMINGHAM-Hard Coronary Heart Disease score were confirmed in an independent validation cohort on 2046 patients. High-sensitivity troponin T provides excellent risk stratification regarding all-cause mortality and all-cause mortality, acute myocardial infarction, and stroke in a secondary prevention cohort in whom risk scores perform poorly. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. When is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?

    DEFF Research Database (Denmark)

    Johansen, Allan; Lomsky, Milan; Gerke, Oke

    2013-01-01

    Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal d...... defects and lower the diagnostic accuracy of the study. The objective was to determine rules of thumb for when reacquisition is useful due to high extra-cardiac uptake, i.e., when interpretation of the studies was affected by poor image quality....

  13. QT and JT dispersion and cardiac performance in children with neonatal Bartter syndrome: a pilot study.

    Science.gov (United States)

    Hacihamdioglu, Duygu Ovunc; Fidanci, Kursat; Kilic, Ayhan; Gok, Faysal; Topaloglu, Rezan

    2013-10-01

    QT dispersion and JT dispersion are simple noninvasive arrhythmogenic markers that can be used to assess the homogeneity of cardiac repolarization. The aim of this study was to assess QT and JT dispersion and their relation with left ventricular systolic and diastolic functions in children with Bartter syndrome (BS). Nine neonatal patients with BS (median age 9.7 years) and 20 controls (median age 8 years) were investigated at rest. Both study and control subjects underwent electrocardiography (ECG) in which the interval between two R waves and QT intervals, corrected QT, QT dispersion, corrected QT dispersion, JT, corrected JT, JT dispersion and corrected JT dispersion were measured with 12-lead ECG. Two-dimensional, Doppler echocardiographic examinations were performed. Patients and controls did not differ for gender and for serum levels of potassium, magnesium, and calcium (p > 0.05). Both study and control subjects had normal echocardiographic examination and baseline myocardial performance indexes. The QT dispersion and JT dispersion were significantly prolonged in patients with BS compared to those of the controls {37.5 ms [interquartile range (IQR) 32.5-40] vs. 25.5 ms (IQR 20-30), respectively, p = 0.014 and 37.5 ms (IQR 27.5-40) vs. 22.5 ms (IQR 20-30), respectively, p = 0.003}. Elevated QT and JT dispersion during asymptomatic and normokalemic periods may be risk factors for the development of cardiac complications and arrhythmias in children with BS. In these patients the need for systematic cardiac screening and management protocol is extremely important for effective prevention.

  14. Identifying High Performance ERP Projects

    OpenAIRE

    Stensrud, Erik; Myrtveit, Ingunn

    2002-01-01

    Learning from high performance projects is crucial for software process improvement. Therefore, we need to identify outstanding projects that may serve as role models. It is common to measure productivity as an indicator of performance. It is vital that productivity measurements deal correctly with variable returns to scale and multivariate data. Software projects generally exhibit variable returns to scale, and the output from ERP projects is multivariate. We propose to use Data Envelopment ...

  15. INL High Performance Building Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Jennifer D. Morton

    2010-02-01

    High performance buildings, also known as sustainable buildings and green buildings, are resource efficient structures that minimize the impact on the environment by using less energy and water, reduce solid waste and pollutants, and limit the depletion of natural resources while also providing a thermally and visually comfortable working environment that increases productivity for building occupants. As Idaho National Laboratory (INL) becomes the nation’s premier nuclear energy research laboratory, the physical infrastructure will be established to help accomplish this mission. This infrastructure, particularly the buildings, should incorporate high performance sustainable design features in order to be environmentally responsible and reflect an image of progressiveness and innovation to the public and prospective employees. Additionally, INL is a large consumer of energy that contributes to both carbon emissions and resource inefficiency. In the current climate of rising energy prices and political pressure for carbon reduction, this guide will help new construction project teams to design facilities that are sustainable and reduce energy costs, thereby reducing carbon emissions. With these concerns in mind, the recommendations described in the INL High Performance Building Strategy (previously called the INL Green Building Strategy) are intended to form the INL foundation for high performance building standards. This revised strategy incorporates the latest federal and DOE orders (Executive Order [EO] 13514, “Federal Leadership in Environmental, Energy, and Economic Performance” [2009], EO 13423, “Strengthening Federal Environmental, Energy, and Transportation Management” [2007], and DOE Order 430.2B, “Departmental Energy, Renewable Energy, and Transportation Management” [2008]), the latest guidelines, trends, and observations in high performance building construction, and the latest changes to the Leadership in Energy and Environmental Design

  16. Safety and efficacy of high-dose melphalan and auto-SCT in patients with AL amyloidosis and cardiac involvement.

    Science.gov (United States)

    Girnius, S; Seldin, D C; Meier-Ewert, H K; Sloan, J M; Quillen, K; Ruberg, F L; Berk, J L; Doros, G; Sanchorawala, V

    2014-03-01

    In Ig light chain (AL) amyloidosis, cardiac involvement is associated with worse prognosis and increased treatment-related complications. In this retrospective cohort study, we assessed survival, hematologic and cardiac responses to high-dose melphalan and auto-SCT (HDM/SCT) in patients with AL amyloidosis and cardiac involvement, stratified by cardiac biomarkers brain natriuretic peptide and Troponin I, analogous to the Mayo cardiac staging. Forty-seven patients underwent HDM/SCT based upon functional measures; six patients had modified cardiac stage I disease, seventeen had modified cardiac stage II disease and twenty-four had modified cardiac stage III disease. Treatment-related mortality was 4% for all patients and 8% for patients with stage III disease. Three-year survival was 88% and EFS was 47%; these did not differ by stage. By intention-to-treat analysis, 27% of patients achieved a hematologic complete response and 32% a very good partial response, of whom 70 and 45%, respectively, have not required additional therapy at 36 months. Cardiac response was achieved in 53% of patients. We conclude that with appropriate patient selection and a risk-adapted treatment approach, HDM/SCT is safe and effective in patients with AL amyloidosis and cardiac involvement.

  17. Exercise Ameliorates High Fat Diet Induced Cardiac Dysfunction by Increasing Interleukin 10

    Directory of Open Access Journals (Sweden)

    Varun eKesherwani

    2015-04-01

    Full Text Available Increasing evidence suggests that a sedentary lifestyle and a high fat diet (HFD leads to cardiomyopathy. Moderate exercise ameliorates cardiac dysfunction, however underlying molecular mechanisms are poorly understood. Increased inflammation due to induction of pro-inflammatory cytokine such as tumor necrosis factor-alpha (TNF-α and attenuation of anti-inflammatory cytokine such as interleukin10 (IL-10 contributes to cardiac dysfunction in obese and diabetics. We hypothesized that exercise training ameliorates HFD- induced cardiac dysfunction by mitigating obesity and inflammation through upregulation of IL-10 and downregulation of TNF-α. To test this hypothesis, eight week old, female C57BL/6J mice were fed with HFD and exercised (swimming 1hr/day for 5 days/week for eight weeks. The four treatment groups: normal diet (ND, HFD, HFD + exercise (HFD + Ex and ND + Ex were analyzed for mean body weight, blood glucose level, TNF-α, IL-10, cardiac fibrosis by Masson Trichrome, and cardiac dysfunction by echocardiography. Mean body weights were increased in HFD but comparatively less in HFD + Ex. The level of TNF-α was elevated and IL-10 was downregulated in HFD but ameliorated in HFD + Ex. Cardiac fibrosis increased in HFD and was attenuated by exercise in the HFD + Ex group. The percentage ejection fraction and fractional shortening were decreased in HFD but comparatively increased in HFD + Ex. There was no difference between ND and ND + Ex for the above parameters except an increase in IL-10 level following exercise. Based on these results, we conclude that exercise mitigates HFD- induced cardiomyopathy by decreasing obesity, inducing IL-10, and reducing TNF-α in mice.

  18. Association of evening smartphone use with cardiac autonomic nervous activity after awakening in adolescents living in high school dormitories.

    Science.gov (United States)

    Nose, Yoko; Fujinaga, Rina; Suzuki, Maki; Hayashi, Ikuyo; Moritani, Toshio; Kotani, Kazuhiko; Nagai, Narumi

    2017-04-01

    Smartphones are prevalently used among adolescents; however, nighttime exposure to blue-enriched light, through electric devices, is known to induce delays of the circadian rhythm phases and poor morning somatic conditions. We therefore investigated whether evening smartphone use may affect sleep-wake cycle and cardiac autonomic nervous system (ANS) activity after awaking in dormitory students. The participants were high school students, living under dormitory rules regarding the curfew, study, meals, lights-out, and wake-up times. The students were forbidden from the use of both television and personal computer in their private rooms, and only the use of a smartphone was permitted. According to prior assessment of smartphone use, we chose age-, sex-, exercise time-matched long (n = 22, >120 min) and short (n = 14, ≤60 min) groups and compared sleep-wake cycle and physiological parameters, such as cardiac ANS activity, blood pressure, and intra-aural temperature. All measurements were performed during 6:30 to 7:00 a.m. in the dormitories. Compared with the short group, the long group showed a significantly lower cardiac ANS activity (2727 ± 308 vs. 4455 ± 667 ms 2 , p = 0.030) with a tendency toward a high heart rate, in addition to later bedtimes during weekdays and more delayed wake-up times over the weekend. Blood pressure and intra-aural temperature did not differ between the groups. In this population, evening smartphone use may be associated with altered sleep-wake cycle and a diminished cardiac ANS activity after awakening could be affecting daytime activities.

  19. High performance fuel technology development

    Energy Technology Data Exchange (ETDEWEB)

    Koon, Yang Hyun; Kim, Keon Sik; Park, Jeong Yong; Yang, Yong Sik; In, Wang Kee; Kim, Hyung Kyu [KAERI, Daejeon (Korea, Republic of)

    2012-01-15

    {omicron} Development of High Plasticity and Annular Pellet - Development of strong candidates of ultra high burn-up fuel pellets for a PCI remedy - Development of fabrication technology of annular fuel pellet {omicron} Development of High Performance Cladding Materials - Irradiation test of HANA claddings in Halden research reactor and the evaluation of the in-pile performance - Development of the final candidates for the next generation cladding materials. - Development of the manufacturing technology for the dual-cooled fuel cladding tubes. {omicron} Irradiated Fuel Performance Evaluation Technology Development - Development of performance analysis code system for the dual-cooled fuel - Development of fuel performance-proving technology {omicron} Feasibility Studies on Dual-Cooled Annular Fuel Core - Analysis on the property of a reactor core with dual-cooled fuel - Feasibility evaluation on the dual-cooled fuel core {omicron} Development of Design Technology for Dual-Cooled Fuel Structure - Definition of technical issues and invention of concept for dual-cooled fuel structure - Basic design and development of main structure components for dual- cooled fuel - Basic design of a dual-cooled fuel rod.

  20. High Performance Bulk Thermoelectric Materials

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Zhifeng [Boston College, Chestnut Hill, MA (United States)

    2013-03-31

    Over 13 plus years, we have carried out research on electron pairing symmetry of superconductors, growth and their field emission property studies on carbon nanotubes and semiconducting nanowires, high performance thermoelectric materials and other interesting materials. As a result of the research, we have published 104 papers, have educated six undergraduate students, twenty graduate students, nine postdocs, nine visitors, and one technician.

  1. Accurate determination of high-risk coronary lesion type by multidetector cardiac computed tomography.

    Science.gov (United States)

    Alasnag, Mirvat; Umakanthan, Branavan; Foster, Gary P

    2008-07-01

    Coronary arteriography (CA) is the standard method to image coronary lesions. Multidetector cardiac computerized tomography (MDCT) provides high-resolution images of coronary arteries, allowing a noninvasive alternative to determine lesion type. To date, no studies have assessed the ability of MDCT to categorize coronary lesion types. The objective of this study was to determine the accuracy of lesion type categorization by MDCT using CA as a reference standard. Patients who underwent both MDCT and CA within 2 months of each other were enrolled. MDCT and CA images were reviewed in a blinded fashion. Lesions were categorized according to the SCAI classification system (Types I-IV). The origin, proximal and middle segments of the major arteries were analyzed. Each segment comprised a data point for comparison. Analysis was performed using the Spearman Correlation Test. Four hundred eleven segments were studied, of which 110 had lesions. The lesion distribution was as follows: 35 left anterior descending (LAD), 29 circumflex (Cx), 31 right coronary artery (RCA), 2 ramus intermedius, 8 diagonal, 4 obtuse marginal and 2 left internal mammary arteries. Correlations between MDCT and CA were significant in all major vessels (LAD, Cx, RCA) (p < 0.001). The overall correlation coefficient was 0.67. Concordance was strong for lesion Types II-IV (97%) and poor for Type I (30%). High-risk coronary lesion types can be accurately categorized by MDCT. This ability may allow MDCT to play an important noninvasive role in the planning of coronary interventions.

  2. High performance in software development

    CERN Multimedia

    CERN. Geneva; Haapio, Petri; Liukkonen, Juha-Matti

    2015-01-01

    What are the ingredients of high-performing software? Software development, especially for large high-performance systems, is one the most complex tasks mankind has ever tried. Technological change leads to huge opportunities but challenges our old ways of working. Processing large data sets, possibly in real time or with other tight computational constraints, requires an efficient solution architecture. Efficiency requirements span from the distributed storage and large-scale organization of computation and data onto the lowest level of processor and data bus behavior. Integrating performance behavior over these levels is especially important when the computation is resource-bounded, as it is in numerics: physical simulation, machine learning, estimation of statistical models, etc. For example, memory locality and utilization of vector processing are essential for harnessing the computing power of modern processor architectures due to the deep memory hierarchies of modern general-purpose computers. As a r...

  3. Pioglitazone improves cardiac function and alters myocardial substrate metabolism without affecting cardiac triglyceride accumulation and high-energy phosphate metabolism in patients with well-controlled type 2 diabetes mellitus

    NARCIS (Netherlands)

    van der Meer, Rutger W.; Rijzewijk, Luuk J.; de Jong, Hugo W. A. M.; Lamb, Hildo J.; Lubberink, Mark; Romijn, Johannes A.; Bax, Jeroen J.; de Roos, Albert; Kamp, Otto; Paulus, Walter J.; Heine, Robert J.; Lammertsma, Adriaan A.; Smit, Johannes W. A.; Diamant, Michaela

    2009-01-01

    Cardiac disease is the leading cause of mortality in type 2 diabetes mellitus (T2DM). Pioglitazone has been associated with improved cardiac outcome but also with an elevated risk of heart failure. We determined the effects of pioglitazone on myocardial function in relation to cardiac high-energy

  4. Impact of Right Ventricular Performance in Patients Undergoing Extracorporeal Membrane Oxygenation Following Cardiac Surgery.

    Science.gov (United States)

    Bartko, Philipp E; Wiedemann, Dominik; Schrutka, Lore; Binder, Christina; Santos-Gallego, Carlos G; Zuckermann, Andreas; Steinlechner, Barbara; Koinig, Herbert; Heinz, Gottfried; Niessner, Alexander; Zimpfer, Daniel; Laufer, Günther; Lang, Irene M; Distelmaier, Klaus; Goliasch, Georg

    2017-07-28

    Extracorporeal membrane oxygenation following cardiac surgery safeguards end-organ oxygenation but unfavorably alters cardiac hemodynamics. Along with the detrimental effects of cardiac surgery to the right heart, this might impact outcome, particularly in patients with preexisting right ventricular (RV) dysfunction. We sought to determine the prognostic impact of RV function and to improve established risk-prediction models in this vulnerable patient cohort. Of 240 patients undergoing extracorporeal membrane oxygenation support following cardiac surgery, 111 had echocardiographic examinations at our institution before implantation of extracorporeal membrane oxygenation and were thus included. Median age was 67 years (interquartile range 60-74), and 74 patients were male. During a median follow-up of 27 months (interquartile range 16-63), 75 patients died. Fifty-one patients died within 30 days, 75 during long-term follow-up (median follow-up 27 months, minimum 5 months, maximum 125 months). Metrics of RV function were the strongest predictors of outcome, even stronger than left ventricular function ( P <0.001 for receiver operating characteristics comparisons). Specifically, RV free-wall strain was a powerful predictor univariately and after adjustment for clinical variables, Simplified Acute Physiology Score-3, tricuspid regurgitation, surgery type and duration with adjusted hazard ratios of 0.41 (95%CI 0.24-0.68; P =0.001) for 30-day mortality and 0.48 (95%CI 0.33-0.71; P <0.001) for long-term mortality for a 1-SD (SD=-6%) change in RV free-wall strain. Combined assessment of the additive EuroSCORE and RV free-wall strain improved risk classification by a net reclassification improvement of 57% for 30-day mortality ( P =0.01) and 56% for long-term mortality ( P =0.02) compared with the additive EuroSCORE alone. RV function is strongly linked to mortality, even after adjustment for baseline variables and clinical risk scores. RV performance improves

  5. Williams Syndrome and Anesthesia for Non-cardiac Surgery: High Risk Can Be Mitigated with Appropriate Planning.

    Science.gov (United States)

    Brown, Morgan L; Nasr, Viviane G; Toohey, Rebecca; DiNardo, James A

    2018-03-23

    Patients with Williams syndrome are considered at high risk for anesthesia-related adverse events. At our institution, all William syndrome patients undergoing cardiac surgical, cardiac catheterization/interventional procedures, and cardiac imaging studies are cared for by cardiac anesthesiologists. All William syndrome patients undergoing non-cardiac surgical, interventional, or imaging studies are cared for by main operating room pediatric anesthesiologists with consultative input from a cardiac anesthesiologist. We reviewed our experience with 75 patients undergoing 202 separate anesthetics for 95 non-cardiac procedures and 107 cardiac procedures from 2012 to 2016. The mean age was 7.5 ± 7.0 years and the mean weight was 22.3 ± 17.0 kg. One hundred and eighty-seven patients had a general anesthetic (92.6%). Medications used included etomidate in 26.2%, propofol in 37.6%, isoflurane in 47.5%, and sevoflurane in 68.3%. Vasopressors and inotropes were required including calcium (22.8%), dopamine (10.4%), norepinephrine (17.3%), phenylephrine (35.1%), vasopressin (0.5%), and ephedrine (5.4%). The median length of stay after anesthesia was 2.8 days (range 0-32). No adverse events occurred in 89.6% of anesthetics. There were two cases of cardiac arrest, one of which required extracorporeal life support for resuscitation. Of the non-cardiac surgical procedures, 95.7% did not have a cardiovascular adverse event. Patients with Williams syndrome are at high risk for anesthesia, especially when undergoing cardiac procedures. The risk can be mitigated with appropriate planning and adherence to the hemodynamic goals for non-cardiac surgical procedures.

  6. High Density Sphere Culture of Adult Cardiac Cells Increases the Levels of Cardiac and Progenitor Markers and Shows Signs of Vasculogenesis

    Directory of Open Access Journals (Sweden)

    Kristina Vukusic

    2013-01-01

    Full Text Available 3D environment and high cell density play an important role in restoring and supporting the phenotypes of cells represented in cardiac tissues. The aim of this study was therefore to investigate the suitability of high density sphere (HDS cultures for studies of cardiomyocyte-, endothelial-, and stem-cell biology. Primary adult cardiac cells from nine human biopsies were cultured using different media for up to 9 weeks. The possibilities to favor a certain cell phenotype and induce production of extra cellular matrix (ECM were studied by histology, immunohistochemistry, and quantitative real-time PCR. Defined media gave significant increase in both cardiac- and progenitor-specific markers and also an intraluminal position of endothelial cells over time. Cardiac media showed indication of differentiation and maturity of HDS considering the ECM production and activities within NOTCH regulation but no additional cardiac differentiation. Endothelial media gave no positive effects on endothelial phenotype but increased proliferation without fibroblast overgrowth. In addition, indications for early vasculogenesis were found. It was also possible to affect the Wnt signaling in HDS by addition of a glycogen synthase kinase 3 (GSK3 inhibitor. In conclusion, these findings show the suitability of HDS as in vitro model for studies of cardiomyocyte-, endothelial-, and stem-cell biology.

  7. Effects of combined mesenchymal stem cells and heme oxygenase-1 therapy on cardiac performance.

    Science.gov (United States)

    Zeng, Bin; Chen, Honglei; Zhu, Chengang; Ren, Xiaofeng; Lin, Guosheng; Cao, Feng

    2008-10-01

    Bone marrow mesenchymal stem cells (MSCs) have the potential to repair the infarcted myocardium and improve cardiac function. However, this approach is limited by its poor viability after transplantation, and controversy still exists over the mechanism by which MSCs contribute to the tissue repair. The human heme oxygenase-1 (hHO-1) was transfected into cultured MSCs using an adenoviral vector. 1 x 10(6) Ad-hHO-1-transfected MSCs (HO-1-MSCs) or Ad-Null-transfected MSCs (Null-MSCs) or PBS only (PBS group) were injected intramyocardially into rat hearts 1h after myocardial infarction. HO-1-MSCs survived in the infarcted myocardium, and expressed hHO-1 mRNA. The expression of basic fibroblast growth factor (bFGF) and vascular endothelial growth factor (VEGF) was significantly enhanced in HO-1-MSCs-treated hearts. At the same time, there were significant reduction of TNF-alpha, IL-1-beta and IL-6 mRNA, and marked increase of IL-10 mRNA in HO-1-MSCs-treated hearts. Moreover, a further downregulation of proapoptotic protein, Bax, and a marked increase in microvessel density were observed in HO-1-MSCs-treated hearts. The infarct size and cardiac performance were also significantly improved in HO-1-MSCs-treated hearts. The combined approach improves MSCs survival and is superior to MSCs injection alone.

  8. High-sensitivity cardiac troponin I assay to screen for acute rejection in patients with heart transplant.

    Science.gov (United States)

    Patel, Parag C; Hill, Douglas A; Ayers, Colby R; Lavingia, Bhavna; Kaiser, Patricia; Dyer, Adrian K; Barnes, Aliessa P; Thibodeau, Jennifer T; Mishkin, Joseph D; Mammen, Pradeep P A; Markham, David W; Stastny, Peter; Ring, W Steves; de Lemos, James A; Drazner, Mark H

    2014-05-01

    A noninvasive biomarker that could accurately diagnose acute rejection (AR) in heart transplant recipients could obviate the need for surveillance endomyocardial biopsies. We assessed the performance metrics of a novel high-sensitivity cardiac troponin I (cTnI) assay for this purpose. Stored serum samples were retrospectively matched to endomyocardial biopsies in 98 cardiac transplant recipients, who survived ≥3 months after transplant. AR was defined as International Society for Heart and Lung Transplantation grade 2R or higher cellular rejection, acellular rejection, or allograft dysfunction of uncertain pathogenesis, leading to treatment for presumed rejection. cTnI was measured with a high-sensitivity assay (Abbott Diagnostics, Abbott Park, IL). Cross-sectional analyses determined the association of cTnI concentrations with rejection and International Society for Heart and Lung Transplantation grade and the performance metrics of cTnI for the detection of AR. Among 98 subjects, 37% had ≥1 rejection episode. cTnI was measured in 418 serum samples, including 35 paired to a rejection episode. cTnI concentrations were significantly higher in rejection versus nonrejection samples (median, 57.1 versus 10.2 ng/L; P<0.0001) and increased in a graded manner with higher biopsy scores (P(trend)<0.0001). The c-statistic to discriminate AR was 0.82 (95% confidence interval, 0.76-0.88). Using a cut point of 15 ng/L, sensitivity was 94%, specificity 60%, positive predictive value 18%, and negative predictive value 99%. A high-sensitivity cTnI assay seems useful to rule out AR in cardiac transplant recipients. If validated in prospective studies, a strategy of serial monitoring with a high-sensitivity cTnI assay may offer a low-cost noninvasive strategy for rejection surveillance. © 2014 American Heart Association, Inc.

  9. Tribute to P.L. Lutz: cardiac performance and cardiovascular regulation during anoxia/Hypoxia in freshwwater turtles

    DEFF Research Database (Denmark)

    Overgaard, J.; Gesser, Hans; Wang, Tobias

    2007-01-01

    Freshwater turtles overwintering in ice-covered ponds in North America may be exposed to prolonged anoxia, and survive this hostile environment by metabolic depression. Here, we review their cardiovascular function and regulation, with particular emphasis on the factors limiting cardiac performance....... The pronounced anoxia tolerance of the turtle heart is based on the ability to match energy consumption with the low anaerobic ATP production during anoxia. Together with a well-developed temporal and spatial energy buffering by creatine kinase, this allows for cellular energy charge to remain high during anoxia....... Furthermore, the turtle heart is well adapted to handle the adverse effects of free phosphate arising when phosphocreatine stores are used. Anoxia causes tenfold reductions in heart rate and blood flows that match the metabolic depression, and blood pressure is largely maintained through increased systemic...

  10. Neo4j high performance

    CERN Document Server

    Raj, Sonal

    2015-01-01

    If you are a professional or enthusiast who has a basic understanding of graphs or has basic knowledge of Neo4j operations, this is the book for you. Although it is targeted at an advanced user base, this book can be used by beginners as it touches upon the basics. So, if you are passionate about taming complex data with the help of graphs and building high performance applications, you will be able to get valuable insights from this book.

  11. Evaluating an undergraduate interprofessional simulation-based educational module: communication, teamwork, and confidence performing cardiac resuscitation skills

    Directory of Open Access Journals (Sweden)

    Marian Luctkar-Flude

    2010-11-01

    Full Text Available Marian Luctkar-Flude1, Cynthia Baker1, Cheryl Pulling1, Robert McGraw2, Damon Dagnone2, Jennifer Medves1, Carly Turner-Kelly11School of Nursing, Queen’s University, Kingston, Ontario, Canada; 2School of Medicine, Queen’s University, Kingston, Ontario, CanadaPurpose: Interprofessional (IP collaboration during cardiac resuscitation is essential and contributes to patient wellbeing. The purpose of this study is to evaluate an innovative simulation-based IP educational module for undergraduate nursing and medical students on cardiac resuscitation skills.Methods: Nursing and medical trainees participated in a new cardiac resuscitation curriculum involving a 2-hour IP foundational cardiac resuscitation skills lab, followed by three 2-hour IP simulation sessions. Control group participants attended the existing two 2-hour IP simulation sessions. Study respondents (N = 71 completed a survey regarding their confidence performing cardiac resuscitation skills and their perceptions of IP collaboration.Results: Despite a consistent positive trend, only one out of 17 quantitative survey items were significantly improved for learners in the new curriculum. They were more likely to report feeling confident managing the airway during cardiac resuscitation (P = 0.001. Overall, quantitative results suggest that senior nursing and medical students were comfortable with IP communication and teamwork and confident with cardiac resuscitation skills. There were no significant differences between nursing students’ and medical students’ results. Through qualitative feedback, participants reported feeling comfortable learning with students from other professions and found value in the IP simulation sessions.Conclusion: Results from this study will inform ongoing restructuring of the IP cardiac resuscitation skills simulation module as defined by the action research process. Specific improvements that are suggested by these findings include strengthening the team

  12. Preventing Sudden Cardiac Death: Automated External Defibrillators in Ohio High Schools.

    Science.gov (United States)

    Lear, Aaron; Hoang, Minh-Ha; Zyzanski, Stephen J

    2015-10-01

    Ohio passed legislation in 2004 for optional public funding of automated external defibrillators (AEDs) in all Ohio high schools. To report occurrences of sudden cardiac arrest in which AEDs were used in Ohio high schools and to evaluate the adherence of Ohio high schools with AEDs to state law and published guidelines on AEDs and emergency action plans (EAPs) in schools. Cross-sectional survey. Web-based survey. A total of 264 of 827 schools that were members of the Ohio High School Athletic Association. We surveyed schools on AED use, AED maintenance, and EAPs. Twenty-five episodes of AED deployment at 22 schools over an 11-year period were reported; 8 (32%) involved students and 17 (68%) involved adults. The reported survival rate was 60% (n = 15). Most events (n = 20, 80%) in both students and adults occurred at or near athletic facilities. The annual use rate of AEDs was 0.7%. Fifty-three percent (n = 140) of schools reported having an EAP in place for episodes of cardiac arrest. Of the schools with EAPs, 57% (n = 80) reported having rehearsed them. Our data supported the placement of AEDs in high schools given the frequency of use for sudden cardiac arrest and the survival rate reported. They also suggested the need for increased awareness of recommendations for EAPs and the need to formulate and practice EAPs. School EAPs should emphasize planning for events in the vicinity of athletic facilities.

  13. OptoDyCE: Automated system for high-throughput all-optical dynamic cardiac electrophysiology

    Science.gov (United States)

    Klimas, Aleksandra; Yu, Jinzhu; Ambrosi, Christina M.; Williams, John C.; Bien, Harold; Entcheva, Emilia

    2016-02-01

    In the last two decades, market were due to cardiac toxicity, where unintended interactions with ion channels disrupt the heart's normal electrical function. Consequently, all new drugs must undergo preclinical testing for cardiac liability, adding to an already expensive and lengthy process. Recognition that proarrhythmic effects often result from drug action on multiple ion channels demonstrates a need for integrative and comprehensive measurements. Additionally, patient-specific therapies relying on emerging technologies employing stem-cell derived cardiomyocytes (e.g. induced pluripotent stem-cell-derived cardiomyocytes, iPSC-CMs) require better screening methods to become practical. However, a high-throughput, cost-effective approach for cellular cardiac electrophysiology has not been feasible. Optical techniques for manipulation and recording provide a contactless means of dynamic, high-throughput testing of cells and tissues. Here, we consider the requirements for all-optical electrophysiology for drug testing, and we implement and validate OptoDyCE, a fully automated system for all-optical cardiac electrophysiology. We demonstrate the high-throughput capabilities using multicellular samples in 96-well format by combining optogenetic actuation with simultaneous fast high-resolution optical sensing of voltage or intracellular calcium. The system can also be implemented using iPSC-CMs and other cell-types by delivery of optogenetic drivers, or through the modular use of dedicated light-sensitive somatic cells in conjunction with non-modified cells. OptoDyCE provides a truly modular and dynamic screening system, capable of fully-automated acquisition of high-content information integral for improved discovery and development of new drugs and biologics, as well as providing a means of better understanding of electrical disturbances in the heart.

  14. High performance MEAs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-15

    The aim of the present project is through modeling, material and process development to obtain significantly better MEA performance and to attain the technology necessary to fabricate stable catalyst materials thereby providing a viable alternative to current industry standard. This project primarily focused on the development and characterization of novel catalyst materials for the use in high temperature (HT) and low temperature (LT) proton-exchange membrane fuel cells (PEMFC). New catalysts are needed in order to improve fuel cell performance and reduce the cost of fuel cell systems. Additional tasks were the development of new, durable sealing materials to be used in PEMFC as well as the computational modeling of heat and mass transfer processes, predominantly in LT PEMFC, in order to improve fundamental understanding of the multi-phase flow issues and liquid water management in fuel cells. An improved fundamental understanding of these processes will lead to improved fuel cell performance and hence will also result in a reduced catalyst loading to achieve the same performance. The consortium have obtained significant research results and progress for new catalyst materials and substrates with promising enhanced performance and fabrication of the materials using novel methods. However, the new materials and synthesis methods explored are still in the early research and development phase. The project has contributed to improved MEA performance using less precious metal and has been demonstrated for both LT-PEM, DMFC and HT-PEM applications. New novel approach and progress of the modelling activities has been extremely satisfactory with numerous conference and journal publications along with two potential inventions concerning the catalyst layer. (LN)

  15. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys.

    OpenAIRE

    Lazzarino, AI; Mindell, JS

    2017-01-01

    Introduction The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subseq...

  16. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys

    OpenAIRE

    Lazzarino, A. I.; Mindell, J. S.

    2017-01-01

    INTRODUCTION: The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subse...

  17. Cardiac Magnetic Resonance Imaging Predictors of Short-Term Outcomes after High Risk Coronary Surgery.

    Science.gov (United States)

    Sheriff, Mohammed J; Mouline, Omar; Hsu, Chijen; Grieve, Stuart M; Wilson, Michael K; Bannon, Paul G; Vallely, Michael P; Puranik, Rajesh

    2016-06-01

    The euroSCORE II is a widely used pre-coronary artery bypass graft surgery (CAGS) risk score, but its predictive power lacks the specificity to predict outcomes in high-risk patients (surgery case mix, revascularisation techniques and related outcomes in recent years. We investigated the utility of Cardiac Magnetic Resonance Imaging (CMRI) in predicting immediate and six-week outcomes after CAGS. Fifty-two consecutive patients with high euroSCORE II (>16) and left ventricular (LV) dysfunction (magnetic resonance imaging parameters were assessed in patients who either had complications immediately post-surgery (n=35), six weeks post-surgery (n=20) or were uncomplicated. The average age of patients recruited was 69±5 years with high euroSCORE II (22±4) and low 2D-echocardiography LV ejection fraction (38%±2%). Cardiac magnetic resonance imaging results demonstrated that those with immediate complications had higher LV scar/infarct burden as a proportion of LV mass (17±3% vs 10±3%; p=0.04) with lower circumferential relaxation index (2.5±0.46 vs 2.8±0.56; p=0.05) compared to those with no complications. Early mortality from surgery was 17% (n=9) and was associated with lower RV stroke volume (55±12 vs 68±18; p=0.03) and higher LV infarct scar/burden (18±2% vs 10±2%, p=0.04). Cardiac magnetic resonance imaging showed patients with complications at six weeks post-surgery had higher LV scar/infarct burden (14.5±2% vs 6.8±2%, p=0.03) compared to those without complications. Cardiac magnetic resonance imaging preoperative LV and RV parameters are valuable in assessing the likelihood of successful outcomes from CAGS in high-risk patients with LV dysfunction. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  18. High Performance Proactive Digital Forensics

    International Nuclear Information System (INIS)

    Alharbi, Soltan; Traore, Issa; Moa, Belaid; Weber-Jahnke, Jens

    2012-01-01

    With the increase in the number of digital crimes and in their sophistication, High Performance Computing (HPC) is becoming a must in Digital Forensics (DF). According to the FBI annual report, the size of data processed during the 2010 fiscal year reached 3,086 TB (compared to 2,334 TB in 2009) and the number of agencies that requested Regional Computer Forensics Laboratory assistance increasing from 689 in 2009 to 722 in 2010. Since most investigation tools are both I/O and CPU bound, the next-generation DF tools are required to be distributed and offer HPC capabilities. The need for HPC is even more evident in investigating crimes on clouds or when proactive DF analysis and on-site investigation, requiring semi-real time processing, are performed. Although overcoming the performance challenge is a major goal in DF, as far as we know, there is almost no research on HPC-DF except for few papers. As such, in this work, we extend our work on the need of a proactive system and present a high performance automated proactive digital forensic system. The most expensive phase of the system, namely proactive analysis and detection, uses a parallel extension of the iterative z algorithm. It also implements new parallel information-based outlier detection algorithms to proactively and forensically handle suspicious activities. To analyse a large number of targets and events and continuously do so (to capture the dynamics of the system), we rely on a multi-resolution approach to explore the digital forensic space. Data set from the Honeynet Forensic Challenge in 2001 is used to evaluate the system from DF and HPC perspectives.

  19. High frequency of cardiac and behavioral complaints as presenting symptoms of hyperthyroidism in children.

    Science.gov (United States)

    Loomba-Albrecht, Lindsey A; Bremer, Andrew A; Styne, Dennis M; Glaser, Nicole S

    2011-01-01

    Descriptive data characterizing the frequency of various chief complaints and presenting symptomatology in children with hyperthyroidism are lacking. Furthermore, difficulties in recognizing atypical presentations may delay diagnosis and increase morbidity. We performed a retrospective review of the medical records of 76 children with hyperthyroidism to characterize their chief complaints at initial presentation to care and document other presenting symptomatology. Cardiac symptoms were the most frequent chief complaint, accounting for 23% of presenting complaints. Major mood and behavior disturbances were also frequently present (21%), but were infrequently cited as the chief complaint (6%). This study is the first to describe chief complaints separately from the other signs and symptoms of hyperthyroidism noted at the time of presentation to medical attention. Cardiac complaints were the most common: however, complaints associated with behavioral and mood disorders also occurred frequently. Clinicians should be aware of these presentations so that hyperthyroidism is diagnosed promptly to avoid morbidity associated with delayed diagnosis.

  20. East meets West: the influence of racial, ethnic and cultural risk factors on cardiac surgical risk model performance.

    Science.gov (United States)

    Soo-Hoo, Sarah; Nemeth, Samantha; Baser, Onur; Argenziano, Michael; Kurlansky, Paul

    2018-01-01

    To explore the impact of racial and ethnic diversity on the performance of cardiac surgical risk models, the Chinese SinoSCORE was compared with the Society of Thoracic Surgeons (STS) risk model in a diverse American population. The SinoSCORE risk model was applied to 13 969 consecutive coronary artery bypass surgery patients from twelve American institutions. SinoSCORE risk factors were entered into a logistic regression to create a 'derived' SinoSCORE whose performance was compared with that of the STS risk model. Observed mortality was 1.51% (66% of that predicted by STS model). The SinoSCORE 'low-risk' group had a mortality of 0.15%±0.04%, while the medium-risk and high-risk groups had mortalities of 0.35%±0.06% and 2.13%±0.14%, respectively. The derived SinoSCORE model had a relatively good discrimination (area under of the curve (AUC)=0.785) compared with that of the STS risk score (AUC=0.811; P=0.18 comparing the two). However, specific factors that were significant in the original SinoSCORE but that lacked significance in our derived model included body mass index, preoperative atrial fibrillation and chronic obstructive pulmonary disease. SinoSCORE demonstrated limited discrimination when applied to an American population. The derived SinoSCORE had a discrimination comparable with that of the STS, suggesting underlying similarities of physiological substrate undergoing surgery. However, differential influence of various risk factors suggests that there may be varying degrees of importance and interactions between risk factors. Clinicians should exercise caution when applying risk models across varying populations due to potential differences that racial, ethnic and geographic factors may play in cardiac disease and surgical outcomes.

  1. Performance characteristics of loci method for measuring cardiac troponin I on the dimension EXL

    Directory of Open Access Journals (Sweden)

    José L. Martín Calderón

    2015-04-01

    Full Text Available Objective: To define the performance characteristics of the LOCI® method for cardiac troponin I on the Dimension EXL system. Designs and methods: Three different levels of commercial control (mean concentrations 0.426, 1.42, and 18.64 µg/L were used for the imprecision study, quantifying separately within-run and between-run over 20 days. The limit of blank (LoB and limit of detection (LoD were assessed with 20 replicates of a sample without troponin I. Linearity was assessed by regression analysis. In addition, we studied inaccuracy, carry-over and limit of quantitation and conducted a method comparison with the Stratus CS (n=69. The reference interval was determined in 146 healthy blood donors using non-parametric method. Results: The within-run imprecision (coefficient of variation [CV], % obtained at each level was 2.4, 1.4% and 2.2%, while the between-run imprecision (CV,% was 3.3%, 2.9% and 2.5%. Total imprecision was 4.06%, 3.3% and 3.4% for each control level. The limit of quantitation which corresponds to the troponin I concentration at which CV=10% was 0.05 µg/L. Method comparison with the Stratus CS assay produced the equation: Dimension EXL=−0.002698+1.0233⁎(Stratus CS with a confidence interval from −0.01562 to 0.00626 for the intercept and (0.979 to 1.0875 for the slope. The 99th percentile obtained for the reference population was 0.047 µg/L. Conclusions: The LOCI method for cardiac troponin I on the Dimension EXL meets all guidelines recommended criteria referring to limit of quantitation, imprecision and shows excellent transferability with the Stratus CS method. Keywords: Cardiac troponin, LOCI, Dimension EXL

  2. Administration of granulocyte-colony stimulating factor accompanied with a balanced diet improves cardiac function alterations induced by high fat diet in mice.

    Science.gov (United States)

    Daltro, Pâmela Santana; Alves, Paula Santana; Castro, Murilo Fagundes; Azevedo, Carine M; Vasconcelos, Juliana Fraga; Allahdadi, Kyan James; de Freitas, Luiz Antônio Rodrigues; de Freitas Souza, Bruno Solano; Dos Santos, Ricardo Ribeiro; Soares, Milena Botelho Pereira; Macambira, Simone Garcia

    2015-12-03

    High fat diet (HFD) is a major contributor to the development of obesity and cardiovascular diseases due to the induction of cardiac structural and hemodynamic abnormalities. We used a model of diabetic cardiomyopathy in C57Bl/6 mice fed with a HFD to investigate the effects of granulocyte-colony stimulating factor (G-CSF), a cytokine known for its beneficial effects in the heart, on cardiac anatomical and functional abnormalities associated with obesity and type 2 diabetes. Groups of C57Bl/6 mice were fed with standard diet (n = 8) or HFD (n = 16). After 36 weeks, HFD animals were divided into a group treated with G-CSF + standard diet (n = 8) and a vehicle control group + standard diet (n = 8). Cardiac structure and function were assessed by electrocardiography, echocardiography and treadmill tests, in addition to the evaluation of body weight, fasting glicemia, insulin and glucose tolerance at different time points. Histological analyses were performed in the heart tissue. HFD consumption induced metabolic alterations characteristic of type 2 diabetes and obesity, as well as cardiac fibrosis and reduced exercise capacity. Upon returning to a standard diet, obese mice body weight returned to non-obese levels. G-CSF administration accelerated the reduction in of body weight in obese mice. Additionally, G-CSF treatment reduced insulin levels, diminished heart fibrosis, increased exercise capacity and reversed cardiac alterations, including bradycardia, elevated QRS amplitude, augmented P amplitude, increased septal wall thickness, left ventricular posterior thickening and cardiac output reduction. Our results indicate that G-CSF administration caused beneficial effects on obesity-associated cardiac impairment.

  3. A randomized controlled trial of levosimendan to reduce mortality in high-risk cardiac surgery patients (CHEETAH): Rationale and design.

    Science.gov (United States)

    Zangrillo, Alberto; Alvaro, Gabriele; Pisano, Antonio; Guarracino, Fabio; Lobreglio, Rosetta; Bradic, Nikola; Lembo, Rosalba; Gianni, Stefano; Calabrò, Maria Grazia; Likhvantsev, Valery; Grigoryev, Evgeny; Buscaglia, Giuseppe; Pala, Giovanni; Auci, Elisabetta; Amantea, Bruno; Monaco, Fabrizio; De Vuono, Giovanni; Corcione, Antonio; Galdieri, Nicola; Cariello, Claudia; Bove, Tiziana; Fominskiy, Evgeny; Auriemma, Stefano; Baiocchi, Massimo; Bianchi, Alessandro; Frontini, Mario; Paternoster, Gianluca; Sangalli, Fabio; Wang, Chew-Yin; Zucchetti, Maria Chiara; Biondi-Zoccai, Giuseppe; Gemma, Marco; Lipinski, Michael J; Lomivorotov, Vladimir V; Landoni, Giovanni

    2016-07-01

    Patients undergoing cardiac surgery are at risk of perioperative low cardiac output syndrome due to postoperative myocardial dysfunction. Myocardial dysfunction in patients undergoing cardiac surgery is a potential indication for the use of levosimendan, a calcium sensitizer with 3 beneficial cardiovascular effects (inotropic, vasodilatory, and anti-inflammatory), which appears effective in improving clinically relevant outcomes. Double-blind, placebo-controlled, multicenter randomized trial. Tertiary care hospitals. Cardiac surgery patients (n = 1,000) with postoperative myocardial dysfunction (defined as patients with intraaortic balloon pump and/or high-dose standard inotropic support) will be randomized to receive a continuous infusion of either levosimendan (0.05-0.2 μg/[kg min]) or placebo for 24-48 hours. The primary end point will be 30-day mortality. Secondary end points will be mortality at 1 year, time on mechanical ventilation, acute kidney injury, decision to stop the study drug due to adverse events or to start open-label levosimendan, and length of intensive care unit and hospital stay. We will test the hypothesis that levosimendan reduces 30-day mortality in cardiac surgery patients with postoperative myocardial dysfunction. This trial is planned to determine whether levosimendan could improve survival in patients with postoperative low cardiac output syndrome. The results of this double-blind, placebo-controlled randomized trial may provide important insights into the management of low cardiac output in cardiac surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Cardiac reactivity and preserved performance under stress: two sides of the same coin?

    Science.gov (United States)

    Pattyn, Nathalie; Mairesse, Olivier; Cortoos, Aisha; Morais, José; Soetens, Eric; Roelands, Bart; van den Nest, Annick; Kolinsky, Régine

    2014-07-01

    In the present experiment, cognitive control under stress was investigated using a real-life paradigm, namely an evaluation flight for military student pilots. The magnitude of cognitive interference on color-word, numerical and emotional Stroop paradigms was studied during a baseline recording and right before the test flight. Cardio-respiratory parameters were simultaneously assessed during rest and the performance of the Stroop tasks. Cognitive data suggested a different speed/accuracy trade-off under stress, and no modulation of the interference effect for color words or numerical stimuli. However, we observed a major increase in error rates for specific emotional stimuli related to the evaluation situation in the stress condition. The increase in cognitive interference from emotional stimuli, expressed as an increase in error rates, was correlated to the decreased cardiac reactivity to challenge in the stress situation. This relationship is discussed in the framework of Sanders' (1983) model of stress and performance. In terms of future research, this link warrants a fruitful lead to be followed for investigating the causal mechanism of performance decrements under the influence of stress. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. High performance light water reactor

    International Nuclear Information System (INIS)

    Squarer, D.; Schulenberg, T.; Struwe, D.; Oka, Y.; Bittermann, D.; Aksan, N.; Maraczy, C.; Kyrki-Rajamaeki, R.; Souyri, A.; Dumaz, P.

    2003-01-01

    The objective of the high performance light water reactor (HPLWR) project is to assess the merit and economic feasibility of a high efficiency LWR operating at thermodynamically supercritical regime. An efficiency of approximately 44% is expected. To accomplish this objective, a highly qualified team of European research institutes and industrial partners together with the University of Tokyo is assessing the major issues pertaining to a new reactor concept, under the co-sponsorship of the European Commission. The assessment has emphasized the recent advancement achieved in this area by Japan. Additionally, it accounts for advanced European reactor design requirements, recent improvements, practical design aspects, availability of plant components and the availability of high temperature materials. The final objective of this project is to reach a conclusion on the potential of the HPLWR to help sustain the nuclear option, by supplying competitively priced electricity, as well as to continue the nuclear competence in LWR technology. The following is a brief summary of the main project achievements:-A state-of-the-art review of supercritical water-cooled reactors has been performed for the HPLWR project.-Extensive studies have been performed in the last 10 years by the University of Tokyo. Therefore, a 'reference design', developed by the University of Tokyo, was selected in order to assess the available technological tools (i.e. computer codes, analyses, advanced materials, water chemistry, etc.). Design data and results of the analysis were supplied by the University of Tokyo. A benchmark problem, based on the 'reference design' was defined for neutronics calculations and several partners of the HPLWR project carried out independent analyses. The results of these analyses, which in addition help to 'calibrate' the codes, have guided the assessment of the core and the design of an improved HPLWR fuel assembly. Preliminary selection was made for the HPLWR scale

  6. Effect of high image compression on the reproducibility of cardiac Sestamibi reporting

    International Nuclear Information System (INIS)

    Thomas, P.; Allen, L.; Beuzeville, S.

    1999-01-01

    Full text: Compression algorithms have been mooted to minimize storage space and transmission times of digital images. We assessed the impact of high-level lousy compression using JPEG and wavelet algorithms on image quality and reporting accuracy of cardiac Sestamibi studies. Twenty stress/rest Sestamibi cardiac perfusion studies were reconstructed into horizontal short, vertical long and horizontal long axis slices using conventional methods. Each of these six sets of slices were aligned for reporting and saved (uncompressed) as a bitmap. This bitmap was then compressed using JPEG compression, then decompressed and saved as a bitmap for later viewing. This process was repeated using the original bitmap and wavelet compression. Finally, a second copy of the original bitmap was made. All 80 bitmaps were randomly coded to ensure blind reporting. The bitmaps were read blinded and by consensus of 2 experienced nuclear medicine physicians using a 5-point scale and 25 cardiac segments. Subjective image quality was also reported using a 3-point scale. Samples of the compressed images were also subtracted from the original bitmap for visual comparison of differences. Results showed an average compression ratio of 23:1 for wavelet and 13:1 for JPEG. Image subtraction showed only very minor discordance between the original and compressed images. There was no significant difference in subjective quality between the compressed and uncompressed images. There was no significant difference in reporting reproducibility of the identical bitmap copy, the JPEG image and the wavelet image compared with the original bitmap. Use of the high compression algorithms described had no significant impact on reporting reproducibility and subjective image quality of cardiac Sestamibi perfusion studies

  7. Measurement of cardiac index by transpulmonary thermodilution using an implanted central venous access port: a prospective study in patients scheduled for oncologic high-risk surgery.

    Science.gov (United States)

    Suria, Stéphanie; Wyniecki, Anne; Eghiaian, Alexandre; Monnet, Xavier; Weil, Grégoire

    2014-01-01

    Transpulmonary thermodilution allows the measurement of cardiac index for high risk surgical patients. Oncologic patients often have a central venous access (port-a-catheter) for chronic treatment. The validity of the measurement by a port-a-catheter of the absolute cardiac index and the detection of changes in cardiac index induced by fluid challenge are unknown. We conducted a monocentric prospective study. 27 patients were enrolled. 250 ml colloid volume expansions for fluid challenge were performed during ovarian cytoreductive surgery. The volume expansion-induced changes in cardiac index measured by transpulmonary thermodilution by a central venous access (CIcvc) and by a port-a-catheter (CIport) were recorded. 23 patients were analyzed with 123 pairs of measurements. Using a Bland and Altman for repeated measurements, the bias (lower and upper limits of agreement) between CIport and CIcvc was 0.14 (-0.59 to 0.88) L/min/m2. The percentage error was 22%. The concordance between the changes in CIport and CIcvc observed during volume expansion was 92% with an r = 0.7 (with exclusion zone). No complications (included sepsis) were observed during the follow up period. The transpulmonary thermodilution by a port-a-catheter is reliable for absolute values estimation of cardiac index and for measurement of the variation after fluid challenge. clinicaltrials.gov NCT02063009.

  8. Cardiac arrest

    Science.gov (United States)

    ... magnesium. These minerals help your heart's electrical system work. Abnormally high or low levels can cause cardiac arrest. Severe physical stress. Anything that causes a severe stress on your ...

  9. High-sugar intake does not exacerbate metabolic abnormalities or cardiac dysfunction in genetic cardiomyopathy.

    Science.gov (United States)

    Hecker, Peter A; Galvao, Tatiana F; O'Shea, Karen M; Brown, Bethany H; Henderson, Reney; Riggle, Heather; Gupte, Sachin A; Stanley, William C

    2012-05-01

    A high-sugar intake increases heart disease risk in humans. In animals, sugar intake accelerates heart failure development by increased reactive oxygen species (ROS). Glucose-6-phosphate dehydrogenase (G6PD) can fuel ROS production by providing reduced nicotinamide adenine dinucleotide phosphate (NADPH) for superoxide generation by NADPH oxidase. Conversely, G6PD also facilitates ROS scavenging using the glutathione pathway. We hypothesized that a high-sugar intake would increase flux through G6PD to increase myocardial NADPH and ROS and accelerate cardiac dysfunction and death. Six-week-old TO-2 hamsters, a non-hypertensive model of genetic cardiomyopathy caused by a δ-sarcoglycan mutation, were fed a long-term diet of high starch or high sugar (57% of energy from sucrose plus fructose). After 24 wk, the δ-sarcoglycan-deficient animals displayed expected decreases in survival and cardiac function associated with cardiomyopathy (ejection fraction: control 68.7 ± 4.5%, TO-2 starch 46.1 ± 3.7%, P sugar 58.0 ± 4.2%, NS, versus TO-2 starch or control; median survival: TO-2 starch 278 d, TO-2 sugar 318 d, P = 0.133). Although the high-sugar intake was expected to exacerbate cardiomyopathy, surprisingly, there was no further decrease in ejection fraction or survival with high sugar compared with starch in cardiomyopathic animals. Cardiomyopathic animals had systemic and cardiac metabolic abnormalities (increased serum lipids and glucose and decreased myocardial oxidative enzymes) that were unaffected by diet. The high-sugar intake increased myocardial superoxide, but NADPH and lipid peroxidation were unaffected. A sugar-enriched diet did not exacerbate ventricular function, metabolic abnormalities, or survival in heart failure despite an increase in superoxide production. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Development of high performance cladding

    International Nuclear Information System (INIS)

    Kiuchi, Kiyoshi

    2003-01-01

    The developments of superior next-generation light water reactor are requested on the basis of general view points, such as improvement of safety, economics, reduction of radiation waste and effective utilization of plutonium, until 2030 year in which conventional reactor plants should be renovate. Improvements of stainless steel cladding for conventional high burn-up reactor to more than 100 GWd/t, developments of manufacturing technology for reduced moderation-light water reactor (RMWR) of breeding ratio beyond 1.0 and researches of water-materials interaction on super critical pressure-water cooled reactor are carried out in Japan Atomic Energy Research Institute. Stable austenite stainless steel has been selected for fuel element cladding of advanced boiling water reactor (ABWR). The austenite stain less has the superiority for anti-irradiation properties, corrosion resistance and mechanical strength. A hard spectrum of neutron energy up above 0.1 MeV takes place in core of the reduced moderation-light water reactor, as liquid metal-fast breeding reactor (LMFBR). High performance cladding for the RMWR fuel elements is required to get anti-irradiation properties, corrosion resistance and mechanical strength also. Slow strain rate test (SSRT) of SUS 304 and SUS 316 are carried out for studying stress corrosion cracking (SCC). Irradiation tests in LMFBR are intended to obtain irradiation data for damaged quantity of the cladding materials. (M. Suetake)

  11. A universal system for highly efficient cardiac differentiation of human induced pluripotent stem cells that eliminates interline variability.

    Directory of Open Access Journals (Sweden)

    Paul W Burridge

    2011-04-01

    Full Text Available The production of cardiomyocytes from human induced pluripotent stem cells (hiPSC holds great promise for patient-specific cardiotoxicity drug testing, disease modeling, and cardiac regeneration. However, existing protocols for the differentiation of hiPSC to the cardiac lineage are inefficient and highly variable. We describe a highly efficient system for differentiation of human embryonic stem cells (hESC and hiPSC to the cardiac lineage. This system eliminated the variability in cardiac differentiation capacity of a variety of human pluripotent stem cells (hPSC, including hiPSC generated from CD34(+ cord blood using non-viral, non-integrating methods.We systematically and rigorously optimized >45 experimental variables to develop a universal cardiac differentiation system that produced contracting human embryoid bodies (hEB with an improved efficiency of 94.7±2.4% in an accelerated nine days from four hESC and seven hiPSC lines tested, including hiPSC derived from neonatal CD34(+ cord blood and adult fibroblasts using non-integrating episomal plasmids. This cost-effective differentiation method employed forced aggregation hEB formation in a chemically defined medium, along with staged exposure to physiological (5% oxygen, and optimized concentrations of mesodermal morphogens BMP4 and FGF2, polyvinyl alcohol, serum, and insulin. The contracting hEB derived using these methods were composed of high percentages (64-89% of cardiac troponin I(+ cells that displayed ultrastructural properties of functional cardiomyocytes and uniform electrophysiological profiles responsive to cardioactive drugs.This efficient and cost-effective universal system for cardiac differentiation of hiPSC allows a potentially unlimited production of functional cardiomyocytes suitable for application to hPSC-based drug development, cardiac disease modeling, and the future generation of clinically-safe nonviral human cardiac cells for regenerative medicine.

  12. Training Program for Cardiology Residents to Perform Focused Cardiac Ultrasound Examination with Portable Device.

    Science.gov (United States)

    Siqueira, Vicente N; Mancuso, Frederico J N; Campos, Orlando; De Paola, Angelo A; Carvalho, Antonio C; Moises, Valdir A

    2015-10-01

    Training requirements for general cardiologists without echocardiographic expertise to perform focused cardiac ultrasound (FCU) with portable devices have not yet been defined. The objective of this study was to evaluate a training program to instruct cardiology residents to perform FCU with a hand-carried device (HCD) in different clinical settings. Twelve cardiology residents were subjected to a 50-question test, 4 lectures on basic echocardiography and imaging interpretation, the supervised interpretation of 50 echocardiograms and performance of 30 exams using HCD. After this period, they repeated the written test and were administered a practical test comprising 30 exams each (360 patients) in different clinical settings. They reported on 15 parameters and a final diagnosis; their findings were compared to the HCD exam of a specialist in echocardiography. The proportion of correct answers on the theoretical test was higher after training (86%) than before (51%; P = 0.001). The agreement was substantial among the 15 parameters analyzed (kappa ranging from 0.615 to 0.891; P < 0.001). The percentage of correct interpretation was lower for abnormal (75%) than normal (95%) items, for valve abnormalities (85%) compared to other items (92%) and for graded scale (87%) than for dichotomous (95%) items (P < 0.0001, for all). For the final diagnoses, the kappa value was higher than 0.941 (P < 0.001; 95% CI [0.914, 0.955]). The training proposed enabled residents to perform FCU with HCD, and their findings were in good agreement with those of a cardiologist specialized in echocardiography. © 2015, Wiley Periodicals, Inc.

  13. Improved oxygenation during standing performance of deep breathing exercises with positive expiratory pressure after cardiac surgery: A randomized controlled trial.

    Science.gov (United States)

    Pettersson, Henrik; Faager, Gun; Westerdahl, Elisabeth

    2015-09-01

    Breathing exercises after cardiac surgery are often performed in a sitting position. It is unknown whether oxygenation would be better in the standing position. The aim of this study was to evaluate oxygenation and subjective breathing ability during sitting vs standing performance of deep breathing exercises on the second day after cardiac surgery. Patients undergoing coronary artery bypass grafting (n = 189) were randomized to sitting (controls) or standing. Both groups performed 3 × 10 deep breaths with a positive expiratory pressure device. Peripheral oxygen saturation was measured before, directly after, and 15 min after the intervention. Subjective breathing ability, blood pressure, heart rate, and pain were assessed. Oxygenation improved significantly in the standing group compared with controls directly after the breathing exercises (p < 0.001) and after 15 min rest (p = 0.027). The standing group reported better deep breathing ability compared with controls (p = 0.004). A slightly increased heart rate was found in the standing group (p = 0.047). After cardiac surgery, breathing exercises with positive expiratory pressure, performed in a standing position, significantly improved oxygenation and subjective breathing ability compared with sitting performance. Performance of breathing exercises in the standing position is feasible and could be a valuable treatment for patients with postoperative hypoxaemia.

  14. Clinical performance of a new point-of-care cardiac troponin I test.

    Science.gov (United States)

    Christ, Michael; Geier, Felicitas; Blaschke, Sabine; Giannitsis, Evangelos; Khellaf, Mehdi; Mair, Johannes; Pariente, David; Scharnhorst, Volkher; Semjonow, Veronique; Hausfater, Pierre

    2018-04-09

    We evaluated the clinical performance of the Minicare cardiac troponin-I (cTnI), a new point-of-care (POC) cTnI test for the diagnosis of acute myocardial infarction (AMI) in a prospective, multicentre study (ISRCTN77371338). Of 474 patients (≥18 years) admitted to an emergency department (ED) or chest pain unit (CPU) with symptoms suggestive of acute coronary syndrome (ACS; ≤12 h from symptom onset), 465 were eligible. Minicare cTnI was tested immediately, 3 h and 6 h after presentation. AMI diagnoses were adjudicated independently based on current guidelines. The diagnostic performance of the Minicare cTnI test at 3 h was similar for whole blood and in plasma: sensitivity 0.92 vs. 0.90; specificity 0.91 vs. 0.90; positive predictive value (PPV) 0.68 vs. 0.66; negative predictive value (NPV) 0.98 vs. 0.98; positive likelihood ratio (LR+) 10.18 vs. 9.41; negative likelihood ratio (LR-) 0.09 vs. 0.11. The optimal diagnostic performance was obtained at 3 h using cut-offs cTnI >43 ng/L plus cTnI change from admission ≥18.5 ng/L: sensitivity 0.90, specificity 0.96, PPV 0.81, NPV 0.98, and LR+ 21.54. The area under the receiver operating characteristics (ROC) curve for cTnI whole blood baseline value and absolute change after 3 h curve was 0.93. These data support the clinical usefulness of Minicare cTnI within a 0 h/3 h-blood sampling protocol supported by current guidelines for the evaluation of suspected ACS.

  15. Ten good reasons why everybody can and should perform cardiac ultrasound in the ICU.

    Science.gov (United States)

    Charron, Cyril; Repessé, Xavier; Bodson, Laurent; Au, Siu-Ming; Vieillard-Baron, Antoine

    2014-01-01

    Critical care ultrasonography (CCUS) has been defined as an ultrasound evaluation of the heart, abdomen, pleura and lungs at the bedside by the intensivist, 24/7. Within CCUS, critical care echocardiography (CCE) is used to assess cardiac function and more generally haemodynamics. Experts in haemodynamics have published a 'consensus of 16' regarding an update on haemodynamic monitoring. They reported the ten key properties of an 'ideal' haemodynamic monitoring system, which perfectly match the ten good reasons we describe here for performing CCE in critically ill patients. Even though unfortunately no evidence-based medicine study is available to support this review, especially regarding CCE-related improvement of outcome, many clinical studies have demonstrated that CCE provides measurements of relevant, accurate, reproducible and interpretable variables, is easy to use, readily available, has a rapid response time, causes no harm, and is cost-effective. Whether it is operator-independent is obviously more debatable and is discussed in this review. All these characteristics are arguments for the extensive use of CCE by intensivists. This is why experts in the field have recommended that a basic level of CCE should be included in the training of all intensivists.

  16. Investigation of occupational radiation exposure during interventional cardiac catheterizations performed via radial artery

    International Nuclear Information System (INIS)

    Goni, H.; Papadopoulou, D.; Yakoumakis, Em; Stratigis, N.; Benos, J.; Siriopoulou, V.; Makri, Tr; Georgiou, Ev

    2005-01-01

    The purpose of this study was to determine the thyroid, sternum and hand radiation doses of radiologists who perform angiographies and angio-plasties via the radial artery. Staff radiation dose was estimated for 21 cardiac interventional catheterizations. Thermoluminescence dosemeters (TLDs) were used to determine radiation dose for each procedure at the right and left wrist, at the sternum and the thyroid. A dose area product (DAP) meter was also attached to give a direct value in Gy cm 2 for each procedure. Staff radiation doses varied between 34 and 235 μGy per procedure at the left wrist, 28 and 172 μGy at the right wrist, 16 and 106 μGy at the level of the thyroid and 16 and 154 μGy at the level of the sternum. The DAP values varied between 25 and 167 Gy cm 2 . Radiation doses in this study are comparable to those reported in previous studies. Moreover, good correlation was found between the DAP values and the occupational dose measured with TLDs. (authors)

  17. Hereditary Hemorrhagic Telangiectasia Presenting as High Output Cardiac Failure during Pregnancy

    Directory of Open Access Journals (Sweden)

    Tareq Goussous

    2009-01-01

    Full Text Available High-output cardiac failure secondary to hepatic involvement is a rare complication of hereditary hemorrhagic telangiectasia (HHT. Here we report a 43-year-old woman who presented at 29 weeks gestation of her second pregnancy with complications of right-sided heart failure and preterm labor. After delivery via cesarean section, the patient was found to have intrahepatic arteriovenous malformations through non-invasive imaging. Subsequently, a family history of vascular malformations and epistaxis was elucidated and a diagnosis of HHT was made. This case is presented, along with a review of the literature and discussion of hepatic involvement in HHT with particular focus on the pregnant patient.

  18. The Doppler echocardiographic myocardial performance index predicts left-ventricular dilation and cardiac death after myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To investigate the value of the Doppler-derived myocardial performance index to predict early left-ventricular (LV) dilation and cardiac death after a first acute myocardial infarction (AMI), Doppler echocardiography was performed within 24 h of hospital admission, on day 5, 1 and 3 months after...... AMI in 125 consecutive patients. The index measured on day 1 correlated well with the change in end-diastolic volume index observed from day 1 to 3 months following AMI (r = 0.66, p 0.0001). One-year survival in patients with Doppler index index > or = 0......, we conclude that the Doppler echocardiographic myocardial performance index is a predictor of LV dilation and cardiac death after a first AMI....

  19. Assessment of cardiac performance with quantitative radionuclide angiocardiography: sequential left ventricular ejection fraction, normalized left ventricular ejection rate, and regional wall motion

    International Nuclear Information System (INIS)

    Marshall, R.C.; Berger, H.J.; Costin, J.C.; Freedman, G.S.; Wolberg, J.; Cohen, L.S.; Gotischalk, A.; Zaret, B.L.

    1977-01-01

    Sequential quantitative first pass radionuclide angiocardiograms (RA) were used to measure left ventricular ejection fraction (LVEF) and left ventricular ejection rate (LVER), and to assess regional wall motion (RWM) in the anterior (ANT) and left anterior oblique (LAO) positions. Studies were obtained with a computerized multicrystal scintillation camera suitable for acquiring high count-rate data. Background was determined in a new fashion by selecting frames temporally from the left ventricular region of interest time-activity curve. A ''representative'' cardiac cycle was formed by summing together counts over three to six cardiac cycles. From this background corrected, high count-rate ''representative''cardiac cycle, LVEF, LVER, and RWM were determined. In 22 patients with normal sinus rhythm in the absence of significant valvular regurgitation, RA LVEF correlated well with that measured by contrast angiography (r = 0.95). LVER correlated well with LVEF measured at contrast angiography (r = 0.90) and allowed complete separation of those with normal (LVER = 3.4 +- 0.17 sec -1 ) and abnormal (LVER = 1.22 +- 0.11 sec -1 ) (P < 0.001) left ventricular performance. This separation was independent of background. Isoproterenol infusion in five normal subjects caused LVER to increase by 81 +- 17% while LVEF increased by 10 +- 2.0%. RWM was correctly defined in 21/22 patients and 89% of left ventricular segments with abnormal wall motion

  20. Noninvasive measurements of cardiac high-energy phosphate metabolites in dilated cardiomyopathy by using 31P spectroscopic chemical shift imaging

    International Nuclear Information System (INIS)

    Hansch, A.; Rzanny, R.; Heyne, J.-P.; Reichenbach, J.R.; Kaiser, W.A.; Leder, U.

    2005-01-01

    Dilated cardiomyopathy (DCM) is accompanied by an impaired cardiac energy metabolism. The aim of this study was to investigate metabolic ratios in patients with DCM compared to controls by using spectroscopic two-dimensional chemical shift imaging (2D-CSI). Twenty volunteers and 15 patients with severe symptoms (left ventricular ejection fraction, LVEF 30%) of DCM were investigated. Cardiac 31 P MR 2D-CSI measurements (voxel size: 40 x 40 x 100 mm 3 ) were performed with a 1.5 T whole-body scanner. Measurement time ranged from 15 min to 30 min. Peak areas and ratios of different metabolites were evaluated, including high-energy phosphates (PCr, ATP), 2,3-diphosphoglycerate (2,3-DPG) and phosphodiesters (PDE). In addition, we evaluated how PCr/ATP ratios correlate with LVEF as an established prognostic factor of heart failure. The PCr/γ-ATP ratio was significantly decreased in patients with moderate and severe DCM and showed a linear correlation with reduced LVEFs. PDE/ATP ratios were significantly increased only in patients with severe DCM as compared to volunteers. Applying 31 P MRS with commonly-available 2D-CSI sequences is a valuable technique to evaluate DCM by determining PCr/ATP ratios noninvasively. In addition to reduced PCr/ATP ratios observed in patients suffering from DCM, significantly-increased PDE/ATP ratios were found in patients with severe DCM. (orig.)

  1. Safety, efficacy, and performance of implanted recycled cardiac rhythm management (CRM) devices in underprivileged patients.

    Science.gov (United States)

    Hasan, Reema; Ghanbari, Hamid; Feldman, Dustin; Menesses, Daniel; Rivas, Daniel; Zakhem, Nicole C; Duarte, Carlos; Machado, Christian

    2011-06-01

    Patients in underdeveloped nations have limited access to life-saving medical technology including cardiac rhythm management (CRM) devices. We evaluated alternative means to provide such technology to this patient population while assessing the safety and efficacy of such a practice. Patients in the United States with clinical indications for extraction of CRM devices were consented. Antemortem CRM devices were cleaned and sterilized following a protocol established at our institution. Surveillance in vitro cultures were performed for quality assurance. The functional status of pulse generators was tested with a pacing system analyzer to confirm at least 70% battery life. Most generators were transported, in person, to an implanting institution in Nicaragua. Recipients with a Class I indication for CRM implantation, and meeting economical criteria set forth, were consented for implantation of a recycled device. Between 2003 and 2009, implantation was performed in 17 patients with an average age of 42.1 ± 20.3 years. Of the 17 patients, nine were male and eight were female. Mean follow-up was 68 ± 38 months. Device evaluation occurred prior to discharge, 4 weeks post implantation, and every 6 months thereafter. There were three deaths during the follow-up period secondary to myocardial infarction, stroke, and heart failure. Hematoma formation occurred in one patient. No infections, early battery depletion, or device malfunction were identified during follow-up. Our case series is the longest follow-up of recipients of recycled antemortem CRM devices. Our findings support the feasibility and safety of this alternative acquisition of life-saving technology. ©2011, The Authors. Journal compilation ©2011 Wiley Periodicals, Inc.

  2. Evaluation of Exercise Performance, Cardiac Function, and Quality of Life in Children After Liver Transplantation.

    Science.gov (United States)

    Vandekerckhove, Kristof; Coomans, Ilse; De Bruyne, Elke; De Groote, Katya; Panzer, Joseph; De Wolf, Daniel; Boone, Jan; De Bruyne, Ruth

    2016-07-01

    In children, after having liver transplantation (LT), it is important to assess the quality of life (QOL). Physical fitness is an important determinant of QOL, and because cardiac function can influence exercise performance, it is the purpose of the present study to assess these factors. Children in stable follow-up for more than 6 months post-LT were invited to participate in a case control study. Patients underwent cardiopulmonary exercise testing and echocardiography to assess systolic and diastolic function, and left ventricular wall dimensions. Health-related QOL was evaluated using child- and adolescent-reported PedsQL questionnaire. Twenty-eight of 31 included patients performed a maximal exercise test (15 boys, 11.6 ± 2.9 years, weight, 40.9 ± 13.1 kg; length, 148.6 ± 17.3 cm; body mass index, 17.6 ± 2.3). Liver transplantation patients had lower maximal oxygen consumption (VO2max/kg) (37.5 ± 9.3 mL/kg per minute vs 44.1 ± 8.8 mL/kg per minute), shorter exercise duration (9.3 ± 2.8 minutes vs 13.3 ± 3 minutes) and lower load (71 ± 14 vs 85 ± 20%). They reached the ventilatory anaerobic threshold earlier (81.4 ± 9.5 vs 88.3 ± 11.9%). Echocardiography demonstrated increased interventricular septal wall thickness (interventricular septum in diastole Z value, +0.45 ± 0.49, P exercise testing. Health-related QOL showed lower overall, emotional, psychosocial, and school functioning scores. Children on antihypertensive medication had impaired physical functioning compared with other LT patients. Lower physical fitness level, more deconditioning and lower health-related QOL in children after LT emphasize the importance of exercise stimulation and fitness programs. Patients on antihypertensive medication seem to be the most vulnerable group suffering from decreased physical fitness.

  3. Cardiac MRI assessment of right ventricular function: impact of right bundle branch block on the evaluation of cardiac performance parameters

    Energy Technology Data Exchange (ETDEWEB)

    Marterer, Robert; Tschauner, Sebastian; Sorantin, Erich [Medical University of Graz, Division of Pediatric Radiology, Department of Radiology, Graz (Austria); Zeng, Hongchun [First Affiliated Hospital of Xinjiang Medical University, Department of Ultrasonography, Urumqi (China); Koestenberger, Martin [Medical University of Graz, Division of Pediatric Cardiology, Department of Pediatrics and Adolescent Medicine, Graz (Austria)

    2015-12-15

    Right ventricular (RV) function represents a prognostic marker in patients with corrected congenital heart disease. In up to 80 % of these patients, right branch bundle block (RBBB) exists and leads to asynchronous ventricular contraction. The aim of this retrospective study was to evaluate the change of RV performance parameters considering delayed RV end-systolic contraction. RV volumes of 33 patients were assessed twice: 1) not taking account of RBBB (group I), and 2) considering RBBB (group II). According to the RV ejection fraction (EF) for both groups, RV function was classified in different categories (>50 % = normal, 40-50 % = mildly-, 30-40 % = moderately-, <30 % = severely-reduced). The mean time difference between maximal systolic contraction of the septum and RV free wall was 90.7 ms ± 42.6. Consequently, RV end-systolic volume was significantly decreased in group II (p < 0.001). Accordingly, RV stroke volume and RV EF were significantly higher in group II (p < 0.001). There was also a significant change in the assessment of RV function (p < 0.02). RBBB induced delayed RV contraction can be detected at CMR. Ignoring the RV physiology in RBBB patients leads to a statistically significant underscoring of RV performance parameters. (orig.)

  4. High-Intensity Interval Training Increases Cardiac Output and V˙O2max.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael A; Namm, Samantha; Fischer, Anthony; Wood, Kimi M

    2017-02-01

    Increases in maximal oxygen uptake (V˙O2max) frequently occur with high-intensity interval training (HIIT), yet the specific adaptation explaining this result remains elusive. This study examined changes in V˙O2max and cardiac output (CO) in response to periodized HIIT. Thirty-nine active men and women (mean age and V˙O2max = 22.9 ± 5.4 yr and 39.6 ± 5.6 mL·kg·min) performed HIIT and 32 men and women (age and V˙O2max = 25.7 ± 4.5 yr and 40.7 ± 5.2 mL·kg·min) were nonexercising controls (CON). The first 10 sessions of HIIT required eight to ten 60 s bouts of cycling at 90%-110% percent peak power output interspersed with 75 s recovery, followed by randomization to one of three regimes (sprint interval training (SIT), high-volume interval training (HIITHI), or periodized interval training (PER) for the subsequent 10 sessions. Before, midway, and at the end of training, progressive cycling to exhaustion was completed during which V˙O2max and maximal CO were estimated. Compared with CON, significant (P HIIT + SIT (39.8 ± 7.3 mL·kg·min to 43.6 ± 6.1 mL·kg·min), HIIT + HIITHI (41.1 ± 4.9 mL·kg·min to 44.6 ± 7.0 mL·kg·min), and HIIT + PER (39.5 ± 5.6 mL·kg·min to 44.1 ± 5.4 mL·kg·min) occurred which were mediated by significant increases in maximal CO (20.0 ± 3.1 L·min to 21.7 ± 3.2 L·min, P = 0.04). Maximal stroke volume was increased with HIIT (P = 0.04), although there was no change in maximal HR (P = 0.88) or arteriovenous O2 difference (P = 0.36). These CO data are accurate and represent the mean changes from pre- to post-HIIT across all three training groups. Increases in V˙O2max exhibited in response to different HIIT regimes are due to improvements in oxygen delivery.

  5. NEWBORNS OF HIGH RISK GROUPS AND ELECTROPHYSIOLOGICAL CARDIAC ACTIVITY DURING THE PERIOD OF EARLY ADAPTATION

    Directory of Open Access Journals (Sweden)

    T. S. Tumaeva

    2014-01-01

    Full Text Available Aim: to study characteristics of electrophysiological cardiac activity in children of risk groups and to assess possibilities of Holter-electrocardiography (H-ECG in revealing of cardiac dysfunction during the period of early adaptation. Patients and methods: 250 newborns were examined. The main group consisted of 200 children with cerebral ischemia (CI. This group was divided into 2 subgroups: 100 full-term and 100 premature (at various gestation age infants. Control group contained 50 children born at 38–40th weeks of gestation with physiological course of pregnancy and delivery, APGAR score of 8–9 points. Complex examination included H-ECG according the standard technic with evaluation of the hearth rate (HR during sleep and wakefulness; HRmin, HRmax; arrhythmias, conductivity disorders, duration of the intervals; rhythm variability. Results: according to the ECG children with CI, especially premature ones, and children delivered via Cesarean section more often had ST-T disturbances, arrhythmias (sinus tachycardia, less often — sinus bradycardia and conductivity disorders, Q-Tc prolongation. H-EGC revealed decrease of sleep HR, HRmin and HRmax in children with CI especially in delivered via Cesarean section. The most common arrhythmia was supraventricular extrasystole.  Pauses in rhythms and variability were the highest in premature children delivered via Cesarean section. Conclusions: hypoxia/ischemia is a trigger for development of cardiovascular dysfuncion in newborns. Premature and children delivered via Cesarean section form a group of high risk. H-ECG widens possibilities of revealing of symptoms of cardiac dysfunction (disturbances at the basal level of functioning, of adaptation resources of the sinus node, electric instability of the myocardium and heart rate variability in children of risk group for development of cardiovascular disorders. 

  6. Fetal cardiac cine imaging using highly accelerated dynamic MRI with retrospective motion correction and outlier rejection.

    Science.gov (United States)

    van Amerom, Joshua F P; Lloyd, David F A; Price, Anthony N; Kuklisova Murgasova, Maria; Aljabar, Paul; Malik, Shaihan J; Lohezic, Maelene; Rutherford, Mary A; Pushparajah, Kuberan; Razavi, Reza; Hajnal, Joseph V

    2018-01-01

    Development of a MRI acquisition and reconstruction strategy to depict fetal cardiac anatomy in the presence of maternal and fetal motion. The proposed strategy involves i) acquisition and reconstruction of highly accelerated dynamic MRI, followed by image-based ii) cardiac synchronization, iii) motion correction, iv) outlier rejection, and finally v) cardiac cine reconstruction. Postprocessing entirely was automated, aside from a user-defined region of interest delineating the fetal heart. The method was evaluated in 30 mid- to late gestational age singleton pregnancies scanned without maternal breath-hold. The combination of complementary acquisition/reconstruction and correction/rejection steps in the pipeline served to improve the quality of the reconstructed 2D cine images, resulting in increased visibility of small, dynamic anatomical features. Artifact-free cine images successfully were produced in 36 of 39 acquired data sets; prolonged general fetal movements precluded processing of the remaining three data sets. The proposed method shows promise as a motion-tolerant framework to enable further detail in MRI studies of the fetal heart and great vessels. Processing data in image-space allowed for spatial and temporal operations to be applied to the fetal heart in isolation, separate from extraneous changes elsewhere in the field of view. Magn Reson Med 79:327-338, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  7. Benefits of cardiac sonography performed by a non-expert sonographer in patients with non-traumatic cardiopulmonary arrest.

    Science.gov (United States)

    Zengin, Suat; Yavuz, Erdal; Al, Behçet; Cindoruk, Şener; Altunbaş, Gökhan; Gümüşboğa, Hasan; Yıldırım, Cuma

    2016-05-01

    The purpose of this study was to evaluate a rapid cardiac ultrasound assessment performed by trained non-expert sonographers integrated into the advanced cardiac life support (ACLS). This study was prospectively performed in 179 patients (104 males and 75 females) who underwent cardiopulmonary resuscitation (CPR) in an emergency department (ED) during two calendar years (2013 and 2014). Two senior doctors, who had received emergency cardiac ultrasonography training, performed cardiac ultrasound through the apical, subxiphoid, or parasternal windows. Ultrasound evaluation and pulse controls were performed simultaneously. SPSS 18.0 was used for statistical analysis. A total of 63.7% (114) of the cardiopulmonary arrest incidents occurred out of the hospital. Only 13 patients had a femoral pulse during the initial evaluation, while 166 showed no femoral pulse. Initial monitoring showed a regular rhythm in 53 patients, ventricular fibrillation in 18 patients, and no rhythms in 108 patients. The first evaluation with ultrasound detected an effective heart rate in 26 patients and ventricular fibrillation in 14 patients, while no effective heart rate was observed in 139 patients. In addition, ultrasound revealed pericardial tamponade in seven patients and right ventricular enlargement in four cases. Global hypokinesia was detected in four patients and hypovolemia was observed in another four patients. The use of real-time ultrasonography during resuscitation with real-time femoral pulse check can help facilitate the distinguishing of pea-type arrest, ascertain the cause of the arrest, infer a suitable treatment, and optimize medical management decisions regarding CPR termination. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Learning Apache Solr high performance

    CERN Document Server

    Mohan, Surendra

    2014-01-01

    This book is an easy-to-follow guide, full of hands-on, real-world examples. Each topic is explained and demonstrated in a specific and user-friendly flow, from search optimization using Solr to Deployment of Zookeeper applications. This book is ideal for Apache Solr developers and want to learn different techniques to optimize Solr performance with utmost efficiency, along with effectively troubleshooting the problems that usually occur while trying to boost performance. Familiarity with search servers and database querying is expected.

  9. High-performance composite chocolate

    Science.gov (United States)

    Dean, Julian; Thomson, Katrin; Hollands, Lisa; Bates, Joanna; Carter, Melvyn; Freeman, Colin; Kapranos, Plato; Goodall, Russell

    2013-07-01

    The performance of any engineering component depends on and is limited by the properties of the material from which it is fabricated. It is crucial for engineering students to understand these material properties, interpret them and select the right material for the right application. In this paper we present a new method to engage students with the material selection process. In a competition-based practical, first-year undergraduate students design, cost and cast composite chocolate samples to maximize a particular performance criterion. The same activity could be adapted for any level of education to introduce the subject of materials properties and their effects on the material chosen for specific applications.

  10. Point of Care Cardiac Troponin Assay Analytical Performances for their Use in Clinical Routine.

    Science.gov (United States)

    Dupuy, Anne M; Baillet, Solenne; Dumont, Richard; Giraud, Isabelle; Badiou, Stephanie; Bargnoux, Anne S; Kuster, Nils; Roubille, Francois; Cristol, Jean Paul

    2017-04-01

    We report the analytical and clinical performances of the Alere Triage Cardiac3© Panel on the Triage MeterPro© instrument, comparing concordance with hs-cTnT results from central laboratory above the respective 99th percentiles and determining the clinical sensitivity within the framework of AMI. The concordance was obtained with these two methods among unselected patients admitted to both the emergency and cardiology departments. The LoD of the assay is 0.010 µg/L. At 99th percentile (0.02 µg/L) the CV was found to be 18%, below the clinically acceptable cutoff of 20%. In the overall population, ROC AUC was not significantly different between the central laboratory assay and POC assay, with 0.952 (95% CI, 0.918 - 0.952) for hs-cTnT concentrations at presentation and 0.953 (95% CI, 0.912 - 0.953) for cTnI. Sensitivity and specificity of hs-cTnT vs. cTnI for AMI (n = 32) were 97% and 78% vs. 91% and 86%, respectively. Our results indicated 90.4% concordance between the two methods using the 99th percentile specific for each assay. The Kappa coefficient was higher than 0.75, and the strength of agreement could be considered to be good. The results of cTnI Alere assays provide similar clinical classification of patients, particularly for the AMI group as compared to the central laboratory hs-cTnT assay and could be suitable for clinical in accordance with the recommendations of Global Task Force guidelines.

  11. High-fat feeding in cardiomyocyte-restricted PPARdelta knockout mice leads to cardiac overexpression of lipid metabolic genes but fails to rescue cardiac phenotypes.

    Science.gov (United States)

    Li, Yuquan; Cheng, Lihong; Qin, Qianhong; Liu, Jian; Lo, Woo-kuen; Brako, Lowrence A; Yang, Qinglin

    2009-10-01

    Peroxisome proliferator-activated receptor delta (PPARdelta) is an essential determinant of basal myocardial fatty acid oxidation (FAO) and bioenergetics. We wished to determine whether increased lipid loading affects the PPARdelta deficient heart in transcriptional regulation of FAO and in the development of cardiac pathology. Cardiomyocyte-restricted PPARdelta knockout (CR-PPARdelta(-/-)) and control (alpha-MyHC-Cre) mice were subjected to 48 h of fasting and to a long-term maintenance on a (28 weeks) high-fat diet (HFD). The expression of key FAO proteins in heart was examined. Serum lipid profiles, cardiac pathology, and changes of various transduction signaling pathways were also examined. Mice subjected to fasting exhibited upregulated transcript expression of FAO genes in the CR-PPARdelta(-/-) hearts. Moreover, long-term HFD in CR-PPARdelta(-/-) mice induced a strikingly greater transcriptional response. After HFD, genes encoding key FAO enzymes were expressed remarkably more in CR-PPARdelta(-/-) hearts than in those of control mice. Despite the marked rise of FAO gene expression, corresponding protein expression remained low in the CR-PPARdelta(-/-) heart, accompanied by abnormalities in sarcomere structures and mitochondria that were similar to those of CR-PPARdelta(-/-) hearts with regular chow feeding. The CR-PPARdelta(-/-) mice displayed increased expression of PPARgamma co-activator-1alpha (PGC-1alpha) and PPARalpha in the heart with deactivated Akt and p42/44 MAPK signaling in response to HFD. We conclude that PPARdelta is an essential determinant of myocardial FAO. Increased lipid intake activates cardiac expression of FAO genes via PPARalpha/PGC-1alpha pathway, albeit it is not sufficient to improve cardiac pathology due to PPARdelta deficiency.

  12. In vitro assessment of cardiac performance after irradiation using an isolated working rat heart preparation

    International Nuclear Information System (INIS)

    Wondergem, J.; Laarse, A. van der; Ravels, F.J.M. van; Wermeskerken, A.-M. van; Verhoeve, H.R.; Graaf, B.W. de; Leer, J.W.H.

    1991-01-01

    The effect of irradiation on cardiac function was assessed using an isolated working rat heart preparation. The animals were given single doses of X-rays in the range 15-30 Gy to their hearts. Cardiac output (CO = aortic flow + coronary flow), heart weight and body weight were followed for a period of 10 months after treatment. Irradiation led to a decrease in cardiac function. This reduction was dose-dependent and progressive with time after treatment. The shape of the Frank-Starling curves constructed for irradiated hearts suggests a loss of contractile function of the myocardium. Coronary flow rates measured in 'working' hearts and in 'Langendorff' hearts were not significantly changed by the irradiation treatment. The isolated working rat heart preparation proved to be a simple and suitable animal model for the investigation of irradiation-induced cardiotoxicity. (author)

  13. A comparative study of defibrillation and cardiopulmonary resuscitation performance during simulated cardiac arrest in nursing student teams

    Directory of Open Access Journals (Sweden)

    Eikeland Husebø Sissel I

    2012-04-01

    Full Text Available Abstract Background Although nurses must be able to respond quickly and effectively to cardiac arrest, numerous studies have demonstrated poor performance. Simulation is a promising learning tool for resuscitation team training but there are few studies that examine simulation for training defibrillation and cardiopulmonary resuscitation (D-CPR in teams from the nursing education perspective. The aim of this study was to investigate the extent to which nursing student teams follow the D-CPR-algorithm in a simulated cardiac arrest, and if observing a simulated cardiac arrest scenario and participating in the post simulation debriefing would improve team performance. Methods We studied video-recorded simulations of D-CPR performance in 28 nursing student teams. Besides describing the overall performance of D-CPR, we compared D-CPR performance in two groups. Group A (n = 14 performed D-CPR in a simulated cardiac arrest scenario, while Group B (n = 14 performed D-CPR after first observing performance of Group A and participating in the debriefing. We developed a D-CPR checklist to assess team performance. Results Overall there were large variations in how accurately the nursing student teams performed the specific parts of the D-CPR algorithm. While few teams performed opening the airways and examination of breathing correctly, all teams used a 30:2 compression: ventilation ratio. We found no difference between Group A and Group B in D-CPR performance, either in regard to total points on the check list or to time variables. Conclusion We found that none of the nursing student teams achieved top scores on the D-CPR-checklist. Observing the training of other teams did not increase subsequent performance. We think all this indicates that more time must be assigned for repetitive practice and reflection. Moreover, the most important aspects of D-CPR, such as early defibrillation and hands-off time in relation to shock, must be highlighted in team

  14. High-Performance Composite Chocolate

    Science.gov (United States)

    Dean, Julian; Thomson, Katrin; Hollands, Lisa; Bates, Joanna; Carter, Melvyn; Freeman, Colin; Kapranos, Plato; Goodall, Russell

    2013-01-01

    The performance of any engineering component depends on and is limited by the properties of the material from which it is fabricated. It is crucial for engineering students to understand these material properties, interpret them and select the right material for the right application. In this paper we present a new method to engage students with…

  15. Toward High-Performance Organizations.

    Science.gov (United States)

    Lawler, Edward E., III

    2002-01-01

    Reviews management changes that companies have made over time in adopting or adapting four approaches to organizational performance: employee involvement, total quality management, re-engineering, and knowledge management. Considers future possibilities and defines a new view of what constitutes effective organizational design in management.…

  16. Single histidine button in cardiac troponin I sustains heart performance in response to severe hypercapnic respiratory acidosis in vivo.

    Science.gov (United States)

    Palpant, Nathan J; D'Alecy, Louis G; Metzger, Joseph M

    2009-05-01

    Intracellular acidosis is a profound negative regulator of myocardial performance. We hypothesized that titrating myofilament calcium sensitivity by a single histidine substituted cardiac troponin I (A164H) would protect the whole animal physiological response to acidosis in vivo. To experimentally induce severe hypercapnic acidosis, mice were exposed to a 40% CO(2) challenge. By echocardiography, it was found that systolic function and ventricular geometry were maintained in cTnI A164H transgenic (Tg) mice. By contrast, non-Tg (Ntg) littermates experienced rapid and marked cardiac decompensation during this same challenge. For detailed hemodymanic assessment, Millar pressure-conductance catheterization was performed while animals were treated with a beta-blocker, esmolol, during a severe hypercapnic acidosis challenge. Survival and load-independent measures of contractility were significantly greater in Tg vs. Ntg mice. This assay showed that Ntg mice had 100% mortality within 5 min of acidosis. By contrast, systolic and diastolic function were protected in Tg mice during acidosis, and they had 100% survival. This study shows that, independent of any beta-adrenergic compensation, myofilament-based molecular manipulation of inotropy by histidine-modified troponin I maintains cardiac inotropic and lusitropic performance and markedly improves survival during severe acidosis in vivo.

  17. In vivo cardiac nano-imaging: A new technology for high-precision analyses of sarcomere dynamics in the heart.

    Science.gov (United States)

    Shimozawa, Togo; Hirokawa, Erisa; Kobirumaki-Shimozawa, Fuyu; Oyama, Kotaro; Shintani, Seine A; Terui, Takako; Kushida, Yasuharu; Tsukamoto, Seiichi; Fujii, Teruyuki; Ishiwata, Shin'ichi; Fukuda, Norio

    2017-03-01

    The cardiac pump function is a result of a rise in intracellular Ca 2+ and the ensuing sarcomeric contractions [i.e., excitation-contraction (EC) coupling] in myocytes in various locations of the heart. In order to elucidate the heart's mechanical properties under various settings, cardiac imaging is widely performed in today's clinical as well as experimental cardiology by using echocardiogram, magnetic resonance imaging and computed tomography. However, because these common techniques detect local myocardial movements at a spatial resolution of ∼100 μm, our knowledge on the sub-cellular mechanisms of the physiology and pathophysiology of the heart in vivo is limited. This is because (1) EC coupling occurs in the μm partition in a myocyte and (2) cardiac sarcomeres generate active force upon a length change of ∼100 nm on a beat-to-beat basis. Recent advances in optical technologies have enabled measurements of intracellular Ca 2+ dynamics and sarcomere length displacements at high spatial and temporal resolution in the beating heart of living rodents. Future studies with these technologies are warranted to open a new era in cardiac research. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Functional High Performance Financial IT

    DEFF Research Database (Denmark)

    Berthold, Jost; Filinski, Andrzej; Henglein, Fritz

    2011-01-01

    at the University of Copenhagen that attacks this triple challenge of increased performance, transparency and productivity in the financial sector by a novel integration of financial mathematics, domain-specific language technology, parallel functional programming, and emerging massively parallel hardware. HIPERFIT......The world of finance faces the computational performance challenge of massively expanding data volumes, extreme response time requirements, and compute-intensive complex (risk) analyses. Simultaneously, new international regulatory rules require considerably more transparency and external...... auditability of financial institutions, including their software systems. To top it off, increased product variety and customisation necessitates shorter software development cycles and higher development productivity. In this paper, we report about HIPERFIT, a recently etablished strategic research center...

  19. High performance Mo adsorbent PZC

    Energy Technology Data Exchange (ETDEWEB)

    Anon,

    1998-10-01

    We have developed Mo adsorbents for natural Mo(n, {gamma}){sup 99}Mo-{sup 99m}Tc generator. Among them, we called the highest performance adsorbent PZC that could adsorb about 250 mg-Mo/g. In this report, we will show the structure, adsorption mechanism of Mo, and the other useful properties of PZC when you carry out the examination of Mo adsorption and elution of {sup 99m}Tc. (author)

  20. Does accelerometer feedback on high-quality chest compression improve survival rate? An in-hospital cardiac arrest simulation.

    Science.gov (United States)

    Jung, Min Hee; Oh, Je Hyeok; Kim, Chan Woong; Kim, Sung Eun; Lee, Dong Hoon; Chang, Wen Joen

    2015-08-01

    We investigated whether visual feedback from an accelerometer device facilitated high-quality chest compressions during an in-hospital cardiac arrest simulation using a manikin. Thirty health care providers participated in an in-hospital cardiac arrest simulation with 1 minute of continuous chest compressions. Chest compressions were performed on a manikin lying on a bed according to visual feedback from an accelerometer feedback device. The manikin and accelerometer recorded chest compression data simultaneously. The simulated patient was deemed to have survived when the chest compression data satisfied all of the preset high-quality chest compression criteria (depth ≥51 mm, rate >100 per minute, and ≥95% full recoil). Survival rates were calculated from the feedback device and manikin data. The survival rate according to the feedback device data was 80%; however, the manikin data indicated a significantly lower survival rate (46.7%; P = .015). The difference between the accelerometer and manikin survival rates was not significant for participants with a body mass index greater than or equal to 20 kg/m(2) (93.3 vs 73.3%, respectively; P = .330); however, the difference in survival rate was significant in participants with body mass index less than 20 kg/m(2) (66.7 vs 20.0%, respectively; P = .025). The use of accelerometer feedback devices to facilitate high-quality chest compression may not be appropriate for lightweight rescuers because of the potential for compression depth overestimation. Clinical Research Information Service (KCT0001449). Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Indoor Air Quality in High Performance Schools

    Science.gov (United States)

    High performance schools are facilities that improve the learning environment while saving energy, resources, and money. The key is understanding the lifetime value of high performance schools and effectively managing priorities, time, and budget.

  2. Upper-body progressive resistance training improves strength and household physical activity performance in women attending cardiac rehabilitation.

    Science.gov (United States)

    Coke, Lola A; Staffileno, Beth A; Braun, Lynne T; Gulanick, Meg

    2008-01-01

    The purpose of this study was to examine the impact of moderate-intensity, progressive, upper-body resistance training (RT) on muscle strength and perceived performance of household physical activities (HPA) among women in cardiac rehabilitation. The 10-week, pretest-posttest, experiment randomized women to either usual care (UC) aerobic exercise or RT. Muscle strength for 5 upper-body RT exercises (chest press, shoulder press, biceps curl, lateral row, and triceps extension) was measured using the 1-Repetition Maximum Assessment. The RT group progressively increased weight lifted using 40%, 50%, and 60% of obtained 1-Repetition Maximum Assessment at 3-week intervals. Perceived performance of HPA was measured with the Kimble Household Activities Scale. The RT group (n = 16, mean age 64 +/- 11) significantly increased muscle strength in all 5 exercises in comparison with the UC group (n = 14, mean age 65 +/- 10) (chest press, 18% vs 11%; shoulder press, 24% vs 14%; biceps curl, 21% vs 12%; lateral row, 32% vs 9%; and triceps extension, 28% vs 20%, respectively). By study end, Household Activities Scale scores significantly increased (F = 13.878, P = .001) in the RT group (8.75 +/- 3.19 vs 11.25 +/- 2.14), whereas scores in the UC group decreased (8.60 +/- 3.11 vs 6.86 +/- 4.13). Progressive upper-body RT in women shows promise as an effective tool to increase muscle strength and improve the ability to perform HPA after a cardiac event. Beginning RT early after a cardiac event in a monitored cardiac rehabilitation environment can maximize the strengthening benefit.

  3. High performance inertial fusion targets

    International Nuclear Information System (INIS)

    Nuckolls, J.H.; Bangerter, R.O.; Lindl, J.D.; Mead, W.C.; Pan, Y.L.

    1977-01-01

    Inertial confinement fusion (ICF) designs are considered which may have very high gains (approximately 1000) and low power requirements (<100 TW) for input energies of approximately one megajoule. These include targets having very low density shells, ultra thin shells, central ignitors, magnetic insulation, and non-ablative acceleration

  4. High performance inertial fusion targets

    International Nuclear Information System (INIS)

    Nuckolls, J.H.; Bangerter, R.O.; Lindl, J.D.; Mead, W.C.; Pan, Y.L.

    1978-01-01

    Inertial confinement fusion (ICF) target designs are considered which may have very high gains (approximately 1000) and low power requirements (< 100 TW) for input energies of approximately one megajoule. These include targets having very low density shells, ultra thin shells, central ignitors, magnetic insulation, and non-ablative acceleration

  5. High performance nuclear fuel element

    International Nuclear Information System (INIS)

    Mordarski, W.J.; Zegler, S.T.

    1980-01-01

    A fuel-pellet composition is disclosed for use in fast breeder reactors. Uranium carbide particles are mixed with a powder of uraniumplutonium carbides having a stable microstructure. The resulting mixture is formed into fuel pellets. The pellets thus produced exhibit a relatively low propensity to swell while maintaining a high density

  6. Dose-modeling study to compare external beam techniques from protocol NSABP B-39/RTOG 0413 for patients with highly unfavorable cardiac anatomy

    International Nuclear Information System (INIS)

    Hiatt, Jessica R.; Evans, Suzanne B.; Price, Lori Lyn; Cardarelli, Gene A.; Di Petrillo, Thomas A.; Wazer, David E.

    2006-01-01

    Purpose: The aim of this study was to select patients with heart anatomy that is specifically unfavorable for tangential irradiation in whole-breast radiotherapy (WBRT), to be used as an experimental cohort to compare cardiac dosimetric and radiobiological parameters of three-dimensional conformal external beam accelerated partial breast irradiation (3D-CRT APBI) to WBRT with techniques as defined by the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 clinical trial. Methods and Materials: A dosimetric modeling study that compared WBRT and 3D-CRT APBI was performed on CT planning data from 8 patients with left-sided breast cancer. Highly unfavorable cardiac anatomy was defined by the measured contact of the myocardium with the anterior chest wall in the axial and para-sagittal planes. Treatment plans of WBRT and 3D-CRT APBI were generated for each patient in accordance with NSABP B-39/RTOG 0413 protocol. Dose-volume relationships of the heart, including the V 5 min (minimum dose delivered to 5% of the cardiac volume), biological effective dose (BED) of the V 5 min, and normal tissue complication probability (NTCP) were analyzed and compared. Results: Despite expected anatomic variation, significantly large differences were found favoring 3D-CRT APBI in cumulative dose-volume histograms (p 5 min (mean difference, 24.53 Gy; p 5 min (85%, p < 0.01). Conclusions: Use of 3D-CRT APBI can demonstrate improved sparing of the heart in select patients with highly unfavorable cardiac anatomy for WBRT, and may result in reduced risk of cardiac morbidity and mortality

  7. High Performance JavaScript

    CERN Document Server

    Zakas, Nicholas

    2010-01-01

    If you're like most developers, you rely heavily on JavaScript to build interactive and quick-responding web applications. The problem is that all of those lines of JavaScript code can slow down your apps. This book reveals techniques and strategies to help you eliminate performance bottlenecks during development. You'll learn how to improve execution time, downloading, interaction with the DOM, page life cycle, and more. Yahoo! frontend engineer Nicholas C. Zakas and five other JavaScript experts -- Ross Harmes, Julien Lecomte, Steven Levithan, Stoyan Stefanov, and Matt Sweeney -- demonstra

  8. Carpet Aids Learning in High Performance Schools

    Science.gov (United States)

    Hurd, Frank

    2009-01-01

    The Healthy and High Performance Schools Act of 2002 has set specific federal guidelines for school design, and developed a federal/state partnership program to assist local districts in their school planning. According to the Collaborative for High Performance Schools (CHPS), high-performance schools are, among other things, healthy, comfortable,…

  9. A Prospective Study of the Timing and Accuracy of Neutrophil Gelatinase-Associated Lipocalin Levels in Predicting Acute Kidney Injury in High-Risk Cardiac Surgery Patients.

    Science.gov (United States)

    Fanning, Niall; Galvin, Sinead; Parke, Rachael; Gilroy, James; Bellomo, Rinaldo; McGuinness, Shay

    2016-01-01

    Neutrophil gelatinase-associated lipocalin (NGAL) appears to be a promising biomarker in the effort to predict acute kidney injury (AKI) after cardiac surgery. The authors aimed to identify the specific time point in the perioperative period at which measurement of either urinary or serum concentrations of NGAL would have the highest predictive power for AKI. The authors also investigated whether change in NGAL from baseline was a better predictor of AKI than absolute NGAL values. A prospective, investigator-blinded observational study. The cardiac surgical unit of a university teaching hospital. The study consisted of 50 patients undergoing cardiac surgery who were classified preoperatively as high risk for developing postoperative AKI. No changes to standard practice were required. The authors performed serial measurements of urinary and serum NGAL concentrations at 18 time points throughout the first 48 postoperative hours and assessed the variables required to diagnose AKI with standard criteria. Statistical analysis of predictive ability was performed using the area under receiver operator curves (AUROC) calculated for each time point. It was demonstrated that urinary NGAL performed marginally better than serum NGAL in predicting AKI. Urinary sampling at 4 and 24 hours after initiation of cardiopulmonary bypass provided the greatest diagnostic ability (AUROC, 0.702 and 0.712, respectively). Absolute NGAL values performed better than changes in NGAL values in predicting AKI. Urinary NGAL performed better than serum NGAL in predicting AKI and was most accurate when measured at 24 hours after initiation of cardiopulmonary bypass; however, NGAL appeared to be at best only a fair predictor of cardiac surgery-associated AKI. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. High performance electromagnetic simulation tools

    Science.gov (United States)

    Gedney, Stephen D.; Whites, Keith W.

    1994-10-01

    Army Research Office Grant #DAAH04-93-G-0453 has supported the purchase of 24 additional compute nodes that were installed in the Intel iPsC/860 hypercube at the Univesity Of Kentucky (UK), rendering a 32-node multiprocessor. This facility has allowed the investigators to explore and extend the boundaries of electromagnetic simulation for important areas of defense concerns including microwave monolithic integrated circuit (MMIC) design/analysis and electromagnetic materials research and development. The iPSC/860 has also provided an ideal platform for MMIC circuit simulations. A number of parallel methods based on direct time-domain solutions of Maxwell's equations have been developed on the iPSC/860, including a parallel finite-difference time-domain (FDTD) algorithm, and a parallel planar generalized Yee-algorithm (PGY). The iPSC/860 has also provided an ideal platform on which to develop a 'virtual laboratory' to numerically analyze, scientifically study and develop new types of materials with beneficial electromagnetic properties. These materials simulations are capable of assembling hundreds of microscopic inclusions from which an electromagnetic full-wave solution will be obtained in toto. This powerful simulation tool has enabled research of the full-wave analysis of complex multicomponent MMIC devices and the electromagnetic properties of many types of materials to be performed numerically rather than strictly in the laboratory.

  11. High-Performance Data Converters

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    -resolution internal D/A converters are required. Unit-element mismatch-shaping D/A converters are analyzed, and the concept of mismatch-shaping is generalized to include scaled-element D/A converters. Several types of scaled-element mismatch-shaping D/A converters are proposed. Simulations show that, when implemented...... in a standard CMOS technology, they can be designed to yield 100 dB performance at 10 times oversampling. The proposed scaled-element mismatch-shaping D/A converters are well suited for use as the feedback stage in oversampled delta-sigma quantizers. It is, however, not easy to make full use of their potential......-order difference of the output signal from the loop filter's first integrator stage. This technique avoids the need for accurate matching of analog and digital filters that characterizes the MASH topology, and it preserves the signal-band suppression of quantization errors. Simulations show that quantizers...

  12. High performance soft magnetic materials

    CERN Document Server

    2017-01-01

    This book provides comprehensive coverage of the current state-of-the-art in soft magnetic materials and related applications, with particular focus on amorphous and nanocrystalline magnetic wires and ribbons and sensor applications. Expert chapters cover preparation, processing, tuning of magnetic properties, modeling, and applications. Cost-effective soft magnetic materials are required in a range of industrial sectors, such as magnetic sensors and actuators, microelectronics, cell phones, security, automobiles, medicine, health monitoring, aerospace, informatics, and electrical engineering. This book presents both fundamentals and applications to enable academic and industry researchers to pursue further developments of these key materials. This highly interdisciplinary volume represents essential reading for researchers in materials science, magnetism, electrodynamics, and modeling who are interested in working with soft magnets. Covers magnetic microwires, sensor applications, amorphous and nanocrystalli...

  13. High performance polyethylene nanocomposite fibers

    Directory of Open Access Journals (Sweden)

    A. Dorigato

    2012-12-01

    Full Text Available A high density polyethylene (HDPE matrix was melt compounded with 2 vol% of dimethyldichlorosilane treated fumed silica nanoparticles. Nanocomposite fibers were prepared by melt spinning through a co-rotating twin screw extruder and drawing at 125°C in air. Thermo-mechanical and morphological properties of the resulting fibers were then investigated. The introduction of nanosilica improved the drawability of the fibers, allowing the achievement of higher draw ratios with respect to the neat matrix. The elastic modulus and creep stability of the fibers were remarkably improved upon nanofiller addition, with a retention of the pristine tensile properties at break. Transmission electronic microscope (TEM images evidenced that the original morphology of the silica aggregates was disrupted by the applied drawing.

  14. A multicentre randomized-controlled trial of inhaled milrinone in high-risk cardiac surgical patients.

    Science.gov (United States)

    Denault, André Y; Bussières, Jean S; Arellano, Ramiro; Finegan, Barry; Gavra, Paul; Haddad, François; Nguyen, Anne Q N; Varin, France; Fortier, Annik; Levesque, Sylvie; Shi, Yanfen; Elmi-Sarabi, Mahsa; Tardif, Jean-Claude; Perrault, Louis P; Lambert, Jean

    2016-10-01

    Inhaled milrinone (iMil) has been used for the treatment of pulmonary hypertension (PH) but its efficacy, safety, and prophylactic effects in facilitating separation from cardiopulmonary bypass (CPB) and preventing right ventricular (RV) dysfunction have not yet been evaluated in a clinical trial. The purpose of this study was to investigate if iMil administered before CPB would be superior to placebo in facilitating separation from CPB. High-risk cardiac surgical patients with PH were randomized to receive iMil or placebo after the induction of anesthesia and before CPB. Hemodynamic parameters and RV function were evaluated by means of pulmonary artery catheterization and transesophageal echocardiography. The groups were compared for the primary outcome of the level of difficulty in weaning from CPB. Among the secondary outcomes examined were the reduction in the severity of PH, the incidence of RV failure, and mortality. Of the 124 patients randomized, the mean (standard deviation [SD]) EuroSCORE II was 8.0 (2.6), and the baseline mean (SD) systolic pulmonary artery pressure (SPAP) was 53 (9) mmHg. The use of iMil was associated with increases in cardiac output (P = 0.03) and a reduction in SPAP (P = 0.04) with no systemic hypotension. Nevertheless, there was no difference in the combined incidence of difficult or complex separation from CPB between the iMil and control groups (30% vs 28%, respectively; absolute difference, 2%; 95% confidence interval [CI], -14 to 18; P = 0.78). There was also no difference in RV failure between the iMil and control groups (15% vs 14%, respectively; difference, 1%; 95% CI, -13 to 12; P = 0.94). Mortality was increased in patients with RV failure vs those without (22% vs 2%, respectively; P < 0.001). In high-risk cardiac surgery patients with PH, the prophylactic use of iMil was associated with favourable hemodynamic effects that did not translate into improvement of clinically relevant endpoints. This trial was registered at

  15. HIGH-PERFORMANCE COATING MATERIALS

    Energy Technology Data Exchange (ETDEWEB)

    SUGAMA,T.

    2007-01-01

    Corrosion, erosion, oxidation, and fouling by scale deposits impose critical issues in selecting the metal components used at geothermal power plants operating at brine temperatures up to 300 C. Replacing these components is very costly and time consuming. Currently, components made of titanium alloy and stainless steel commonly are employed for dealing with these problems. However, another major consideration in using these metals is not only that they are considerably more expensive than carbon steel, but also the susceptibility of corrosion-preventing passive oxide layers that develop on their outermost surface sites to reactions with brine-induced scales, such as silicate, silica, and calcite. Such reactions lead to the formation of strong interfacial bonds between the scales and oxide layers, causing the accumulation of multiple layers of scales, and the impairment of the plant component's function and efficacy; furthermore, a substantial amount of time is entailed in removing them. This cleaning operation essential for reusing the components is one of the factors causing the increase in the plant's maintenance costs. If inexpensive carbon steel components could be coated and lined with cost-effective high-hydrothermal temperature stable, anti-corrosion, -oxidation, and -fouling materials, this would improve the power plant's economic factors by engendering a considerable reduction in capital investment, and a decrease in the costs of operations and maintenance through optimized maintenance schedules.

  16. Clinical application of transvenous temporary cardiac pacemaker in performing extra-cranial carotid angiography and stent implantation

    International Nuclear Information System (INIS)

    Liu Juan; Yao Guoen; Zhou Huadong; Jiang Xiaojiang; Chen Qiao

    2012-01-01

    Objective: To assess the safety and effectiveness of transvenous temporary cardiac pacemaker in preventing hemodynamic instability occurred during the perioperative period of extra-cranial carotid angiography and stent implantation. Methods: Preoperative install of temporary cardiac pacemaker via left femoral vein was carried out in 41 patients who were at high risk for developing hemodynamic instability, which was followed by extra-cranial carotid angiography and stent implantation. The pacing rhythm of the pacemaker was fixed at 60 beats/min. During and after the procedure the patients were under close observation for the signs of discomfort symptoms as well as the changes in blood pressure and heart rate. The working condition of the pacemaker was also monitored. Results: All the installed pacemakers were technically and hemodynamically effective in producing electrical ventricular responses in all 25 patients who had received balloon dilatation of carotid in advance. Transient pacemaker activation appeared in 25 patients. The longest activation time was one day. During pacemaker activation, one patient developed symptomatic hypotension. The longest duration of hypotension lasted for 4 days. No pacemaker-related or procedure-related complications occurred. Conclusion: Hemodynamic instability is a common complication occurred during perioperative period of extra-cranial carotid angiography and stent implantation. As a prophylactic measure, preoperative placement of temporary cardiac pacemaker can promptly and effectively correct the hemodynamic disorders and prevent perioperative complications such as stroke, etc. Therefore, this technique is worth employing in clinical practice, and it is especially useful for patients with high risks. (authors)

  17. Discrete event simulation model of sudden cardiac death predicts high impact of preventive interventions.

    Science.gov (United States)

    Andreev, Victor P; Head, Trajen; Johnson, Neil; Deo, Sapna K; Daunert, Sylvia; Goldschmidt-Clermont, Pascal J

    2013-01-01

    Sudden Cardiac Death (SCD) is responsible for at least 180,000 deaths a year and incurs an average cost of $286 billion annually in the United States alone. Herein, we present a novel discrete event simulation model of SCD, which quantifies the chains of events associated with the formation, growth, and rupture of atheroma plaques, and the subsequent formation of clots, thrombosis and on-set of arrhythmias within a population. The predictions generated by the model are in good agreement both with results obtained from pathological examinations on the frequencies of three major types of atheroma, and with epidemiological data on the prevalence and risk of SCD. These model predictions allow for identification of interventions and importantly for the optimal time of intervention leading to high potential impact on SCD risk reduction (up to 8-fold reduction in the number of SCDs in the population) as well as the increase in life expectancy.

  18. Factors affecting high-sensitivity cardiac troponin T elevation in Japanese metabolic syndrome patients

    Directory of Open Access Journals (Sweden)

    Hitsumoto T

    2015-03-01

    Full Text Available Takashi Hitsumoto,1 Kohji Shirai2 1Hitsumoto Medical Clinic, Yamaguchi, Japan; 2Department of Vascular Function (donated, Sakura Hospital, Toho University School of Medicine, Chiba, Japan Purpose: The blood concentration of cardiac troponin T (ie, high-sensitivity cardiac troponin T [hs-cTnT], measured using a highly sensitive assay, represents a useful biomarker for evaluating the pathogenesis of heart failure or predicting cardiovascular events. However, little is known about the clinical significance of hs-cTnT in metabolic syndrome. The aim of this study was to examine the factors affecting hs-cTnT elevation in Japanese metabolic syndrome patients. Patients and methods: We enrolled 258 metabolic syndrome patients who were middle-aged males without a history of cardiovascular events. We examined relationships between hs-cTnT and various clinical parameters, including diagnostic parameters of metabolic syndrome. Results: There were no significant correlations between hs-cTnT and diagnostic parameters of metabolic syndrome. However, hs-cTnT was significantly correlated with age (P<0.01, blood concentrations of brain natriuretic peptide (P<0.01, reactive oxygen metabolites (markers of oxidative stress, P<0.001, and the cardio–ankle vascular index (marker of arterial function, P<0.01. Furthermore, multiple regression analysis revealed that these factors were independent variables for hs-cTnT as a subordinate factor. Conclusion: The findings of this study indicate that in vivo oxidative stress and abnormality of arterial function are closely associated with an increase in hs-cTnT concentrations in Japanese metabolic syndrome patients. Keywords: troponin, metabolic syndrome, risk factor, oxidative stress, cardio–ankle vascular index

  19. High Trypanosoma cruzi infection prevalence associated with minimal cardiac pathology among wild carnivores in central Texas

    Directory of Open Access Journals (Sweden)

    Rachel Curtis-Robles

    2016-08-01

    Full Text Available Infection with the zoonotic vector-borne protozoal parasite Trypanosoma cruzi causes Chagas disease in humans and dogs throughout the Americas. Despite the recognized importance of various wildlife species for perpetuating Trypanosoma cruzi in nature, relatively little is known about the development of cardiac disease in infected wildlife. Using a cross-sectional study design, we collected cardiac tissue and blood from hunter-donated wildlife carcasses- including raccoon (Procyon lotor, coyote (Canis latrans, gray fox (Urocyon cinereoargenteus, and bobcat (Lynx rufus – from central Texas, a region with established populations of infected triatomine vectors and increasing diagnoses of Chagas disease in domestic dogs. Based on PCR analysis, we found that 2 bobcats (14.3%, 12 coyotes (14.3%, 8 foxes (13.8%, and 49 raccoons (70.0% were positive for T. cruzi in at least one sample (right ventricle, apex, and/or blood clot. Although a histologic survey of right ventricles showed that 21.1% of 19 PCR-positive hearts were characterized by mild lymphoplasmocytic infiltration, no other lesions and no amastigotes were observed in any histologic section. DNA sequencing of the TcSC5D gene revealed that raccoons were infected with T. cruzi strain TcIV, and a single racoon harbored a TcI/TcIV mixed infection. Relative to other wildlife species tested here, our data suggest that raccoons may be important reservoirs of TcIV in Texas and a source of infection for indigenous triatomine bugs. The overall high level of infection in this wildlife community likely reflects high levels of vector contact, including ingestion of bugs. Although the relationship between the sylvatic cycle of T. cruzi transmission and human disease risk in the United States has yet to be defined, our data suggest that hunters and wildlife professionals should take precautions to avoid direct contact with potentially infected wildlife tissues.

  20. Cardiac findings in 31 patients with Noonan's syndrome

    Directory of Open Access Journals (Sweden)

    Bertola Débora Romeo

    2000-01-01

    Full Text Available OBJECTIVE: To evaluate cardiac findings in 31 Noonan syndrome patients. METHODS: Thirty-one (18 males and 13 femalespatients from 26 families affected with Noonan's syndrome were evaluated from the cardiac point of view with electrocardiography and echodopplercardiography. RESULTS: Twenty patients had some type of cardiac abnormality. The most frequent was pulmonary valve stenosis followed by hypertrophic myocardiopathy, commonly associated with valve defects. Upper deviation of the QRS axis was observed in 80% of these patients. CONCLUSION: In view of the high frequency and diversity of cardiac abnormalities present in Noonan syndrome, cardiac evaluation with electrocardiography and echocardiography should be performed in all patients diagnostically suspected of having this disease.

  1. Delivering high performance BWR fuel reliably

    International Nuclear Information System (INIS)

    Schardt, J.F.

    1998-01-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  2. Study of High Sensitive-CRP and Cardiac Marker Enzymes in Acute Coronary Syndrome

    Directory of Open Access Journals (Sweden)

    Srikrishna R,

    2015-04-01

    Full Text Available Background: Inflammation has been proposed as a contributor to different stages in the pathogenesis of Coronary Heart Disease (CHD. High sensitive C-Reactive Protein (hs-CRP, an acute-phase plasma protein synthesized by the liver, is the most extensively studied systemic marker of inflammation. Elevated hsCRP concentrations early in Acute Coronary Syndrome (ACS, prior to the tissue necrosis, may be a surrogate marker for cardiovascular co-morbidities. The cardiac marker enzymes Creatine Kinase myocardial bound (CK-MB, Aspartate Aminotransferase (AST and lactate dehydrogenase (LDH have been known to be increased in coronary artery diseases. Objective: The aim of the study was to measure hs-CRP levels and other cardiac marker enzymes in ACS patients and to compare the levels of hs-CRP with other cardiac marker enzymes between ST Elevation Myocardial Infarction (STEMI and Non-ST Elevation Myocardial Infarction (NSTEMI patients. Material and Methods: The study group consisted of 207 consecutive patients admitted to Sri Siddhartha Medical College Hospital within the first 6 hours from the onset of chest pain. Patients were diagnosed as Unstable Angina (UA, (n=84; STEMI (n=63 and NSTEMI (n=60. ACS patients were compared with 211 healthy age and sex matched controls. Hs-CRP, CK-MB, AST and LDH levels were measured by standard methods in both groups at baseline and forcases at 36-48 hours i.e. Peak levels. Results: ACS patients had significantly (p<0.05 higher levels of hs-CRP, CKMB, AST and LDH in comparison to controls at baseline. Hs-CRP, CK-MB, AST and LDH levels were significantly higher in STEMI patients compared to NSTEMI patients (p<0.05 at baseline. There was a significant difference regarding peak hs-CRP levels between the two groups, as STEMI patients had significantly higher peak hs-CRP levels compared to NSTEMI patients (p<0.05. Conclusion: STEMI patients have significantly higher peak hsCRP levels compared to NSTEMI patients. These data

  3. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay.

    Science.gov (United States)

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-08-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.

  4. Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function.

    Science.gov (United States)

    Liu, Jing; Feng, Li; Shen, Hsin-Wei; Zhu, Chengcheng; Wang, Yan; Mukai, Kanae; Brooks, Gabriel C; Ordovas, Karen; Saloner, David

    2017-08-01

    This work presents a highly-accelerated, self-gated, free-breathing 3D cardiac cine MRI method for cardiac function assessment. A golden-ratio profile based variable-density, pseudo-random, Cartesian undersampling scheme was implemented for continuous 3D data acquisition. Respiratory self-gating was achieved by deriving motion signal from the acquired MRI data. A multi-coil compressed sensing technique was employed to reconstruct 4D images (3D+time). 3D cardiac cine imaging with self-gating was compared to bellows gating and the clinical standard breath-held 2D cine imaging for evaluation of self-gating accuracy, image quality, and cardiac function in eight volunteers. Reproducibility of 3D imaging was assessed. Self-gated 3D imaging provided an image quality score of 3.4 ± 0.7 vs 4.0 ± 0 with the 2D method (p = 0.06). It determined left ventricular end-systolic volume as 42.4 ± 11.5 mL, end-diastolic volume as 111.1 ± 24.7 mL, and ejection fraction as 62.0 ± 3.1%, which were comparable to the 2D method, with bias ± 1.96 × SD of -0.8 ± 7.5 mL (p = 0.90), 2.6 ± 3.3 mL (p = 0.84) and 1.4 ± 6.4% (p = 0.45), respectively. The proposed 3D cardiac cine imaging method enables reliable respiratory self-gating performance with good reproducibility, and provides comparable image quality and functional measurements to 2D imaging, suggesting that self-gated, free-breathing 3D cardiac cine MRI framework is promising for improved patient comfort and cardiac MRI scan efficiency.

  5. The cardiac safety of aripiprazole treatment in patients at high risk for torsade

    DEFF Research Database (Denmark)

    Polcwiartek, Christoffer; Sneider, Benjamin; Graff, Claus

    2015-01-01

    RATIONALE: Certain antipsychotics increase the risk of heart rate-corrected QT (QTc) prolongation and consequently Torsades de Pointes (TdP) and sudden cardiac death (SCD). Drug-induced Brugada syndrome (BrS) is also associated with SCD. Most SCDs occur in patients with additional cardiac risk fa...

  6. Plasma Levels of High Sensitivity Cardiac Troponin T in Adults with Repaired Tetralogy of Fallot

    Science.gov (United States)

    Lai, Clare T. M.; Wong, Sophia J.; Ip, Janice J. K.; Wong, Wai-keung; Tsang, Kwong-cheong; Lam, Wendy W. M.; Cheung, Yiu-fai

    2015-01-01

    Detectable low circulating level of cardiac troponin T (cTnT) may reflect subclinical myocardial injury. We tested the hypothesis that circulating levels of hs-cTnT are altered in adults with repaired tetralogy of Fallot (TOF) and associated with ventricular volume load and function. Eighty-eight TOF patients and 48 controls were studied. Plasma hs-cTnT levels were determined using a highly sensitive assay (hs-cTnT). The right (RV) and left ventricular (LV) volumes and ejection fraction (EF) were measured using 3D echocardiography and, in 52 patients, cardiac magnetic resonance (CMR). The median (interquartile range) for male and female patients were 4.87 (3.83–6.62) ng/L and 3.11 (1.00–3.87) ng/L, respectively. Thirty percent of female but none of the male patients had increased hs-cTnT levels. Female patients with elevated hs-cTnT levels, compared to those without, had greater RV end-diastolic and end-systolic volumes and LV systolic dyssynchrony index (all p < 0.05). For patient cohort only, hs-cTnT levels correlated positively with CMR-derived RV end-diastolic volume and negatively with echocardiography-derived LV and RV EF (all p < 0.05). Multiple linear regression identified sex and RV EF as significant correlates of log-transformed hs-cTnT levels. Increased hs-cTnT levels occur in 30% of female patients after TOF repair, and are associated with greater RV volumes and worse RV EF. PMID:26360613

  7. Andrographis paniculata extract attenuates pathological cardiac hypertrophy and apoptosis in high-fat diet fed mice.

    Science.gov (United States)

    Hsieh, You-Liang; Shibu, Marthandam Asokan; Lii, Chong-Kuei; Viswanadha, Vijaya Padma; Lin, Yi-Lin; Lai, Chao-Hung; Chen, Yu-Feng; Lin, Kuan-Ho; Kuo, Wei-Wen; Huang, Chih-Yang

    2016-11-04

    Andrographis paniculata (Burm. f.) Nees (Acanthaceae) has a considerable medicinal reputation in most parts of Asia as a potent medicine in the treatment of Endocrine disorders, inflammation and hypertension. Water extract of A. paniculata and its active constituent andrographolide are known to possess anti-inflammatory and anti-apoptotic effects. Our aim is to identify whether A. paniculata extract could protect myocardial damage in high-fat diet induced obese mice. The test mice were divided into three groups fed either with normal chow or with high fat diet (obese) or with high fat diet treated with A. paniculata extract (2g/kg/day, through gavage, for a week). We found that the myocardial inflammation pathway related proteins were increased in the obese mouse which potentially contributes to cardiac hypertrophy and myocardial apoptosis. But feeding with A. paniculata extract showed significant inhibition on the effects of high fat diet. Our study strongly suggests that supplementation of A. paniculata extract can be used for prevention and treatment of cardiovascular disease in obese patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Short-term adaptation and chronic cardiac remodelling to high altitude in lowlander natives and Himalayan Sherpa.

    Science.gov (United States)

    Stembridge, Mike; Ainslie, Philip N; Shave, Rob

    2015-11-01

    What is the topic of this review? At high altitude, the cardiovascular system must adapt in order to meet the metabolic demand for oxygen. This review summarizes recent findings relating to short-term and life-long cardiac adaptation to high altitude in the context of exercise capacity. What advances does it highlight? Both Sherpa and lowlanders exhibit smaller left ventricular volumes at high altitude; however, myocardial relaxation, as evidenced by diastolic untwist, is reduced only in Sherpa, indicating that short-term hypoxia does not impair diastolic relaxation. Potential remodelling of systolic function, as evidenced by lower left ventricular systolic twist in Sherpa, may facilitate the requisite sea-level mechanical reserve required during exercise, although this remains to be confirmed. Both short-term and life-long high-altitude exposure challenge the cardiovascular system to meet the metabolic demand for O2 in a hypoxic environment. As the demand for O2 delivery increases during exercise, the circulatory component of oxygen transport is placed under additional stress. Acute adaptation and chronic remodelling of cardiac structure and function may occur to facilitate O2 delivery in lowlanders during sojourn to high altitude and in permanent highland residents. However, our understanding of cardiac structural and functional adaption in Sherpa remains confined to a higher maximal heart rate, lower pulmonary vascular resistance and no differences in resting cardiac output. Ventricular form and function are intrinsically linked through the left ventricular (LV) mechanics that facilitate efficient ejection, minimize myofibre stress during contraction and aid diastolic recoil. Recent examination of LV mechanics has allowed detailed insight into fundamental cardiac adaptation in high-altitude Sherpa. In this symposium report, we review recent advances in our understanding of LV function in both lowlanders and Sherpa at rest and discuss the potential consequences

  9. Prenatal screening for major congenital heart disease: assessing performance by combining national cardiac audit with maternity data.

    Science.gov (United States)

    Gardiner, Helena M; Kovacevic, Alexander; van der Heijden, Laila B; Pfeiffer, Patricia W; Franklin, Rodney Cg; Gibbs, John L; Averiss, Ian E; Larovere, Joan M

    2014-03-01

    Determine maternity hospital and lesion-specific prenatal detection rates of major congenital heart disease (mCHD) for hospitals referring prenatally and postnatally to one Congenital Cardiac Centre, and assess interhospital relative performance (relative risk, RR). We manually linked maternity data (3 hospitals prospectively and another 16 retrospectively) with admissions, fetal diagnostic and surgical cardiac data from one Congenital Cardiac Centre. This Centre submits verified information to National Institute for Cardiovascular Outcomes Research (NICOR-Congenital), which publishes aggregate antenatal diagnosis data from infant surgical procedures. We included 120 198 unselected women screened prospectively over 11 years in 3 maternity hospitals (A, B, C). Hospital A: colocated with fetal medicine, proactive superintendent, on-site training, case-review and audit, hospital B: on-site training, proactive superintendent, monthly telemedicine clinics, and hospital C: sonographers supported by local obstetrician. We then studied 321 infants undergoing surgery for complete transposition (transposition of the great arteries (TGA), n=157) and isolated aortic coarctation (CoA, n=164) screened in hospitals A, B, C prospectively, and 16 hospitals retrospectively. 385 mCHD recorded prospectively from 120 198 (3.2/1000) screened women in 3 hospitals. Interhospital relative performance (RR) in Hospital A:1.68 (1.4 to 2.0), B:0.70 (0.54 to 0.91), C:0.65 (0.5 to 0.8). Standardised prenatal detection rates (funnel plots) demonstrating inter-hospital variation across 19 hospitals for TGA (37%, 0.00 to 0.81) and CoA (34%, 0.00 to 1.06). Manually linking data sources produced hospital-specific and lesion-specific prenatal mCHD detection rates. More granular, rather than aggregate, data provides meaningful feedback to improve screening performance. Automatic maternal and infant record linkage on a national scale, requires verified, prospective maternity audit and integration of

  10. High performance carbon nanocomposites for ultracapacitors

    Science.gov (United States)

    Lu, Wen

    2012-10-02

    The present invention relates to composite electrodes for electrochemical devices, particularly to carbon nanotube composite electrodes for high performance electrochemical devices, such as ultracapacitors.

  11. Effect of perilipin-5 on apoptosis of cardiac microvascular endothelial cells induced by high fat and high glucose in mice

    Directory of Open Access Journals (Sweden)

    Jin DU

    2017-12-01

    Full Text Available Objective To investigate the effects and mechanisms of perilipin-5 (Plin5 on the apoptosis of mouse cardiac microvascular endothelial cells induced by high fat and high glucose. Methods The mouse cardiac microvascular endothelial cells (MCMECs cultured with high glucose medium were respectively given 0, 100, 300 and 500μmol/L palmitic acid for 24 hours. In order to explore the effects and mechanisms of Plin5 on MCMECs injuries induced by high fat and high glucose, MCMECs exposed to 300μmol/L palmitic acid for 24 hours were divided into control group, Scra siRNA group and Plin5 siRNA group. The control group was only treated with transfection reagent, the Scra siRNA group was given treatment of transfection reagent and garbled RNA, the Plin5 siRNA group was given treatment of transfection reagent and Plin5 specific siRNA. In order to further confirm the specific mechanism of Plin5 in high fat/glucose inducing MCMECs injury, MCMECs in Plin5 siRNA group were divided into vehicle group and N-acetyl cysteine (NAC group, and given the same intervention of high fat. The apoptotic rate was detected by flow cytometry, qRT-PCR and Western blotting were respectively used to detect the mRNA and protein expression of Plin5, and the intracellular reactive oxygen species (ROS level was tested by DHE staining and ELISA kit. Results The apoptotic rate of MCMECs was increased in a fat concentration-dependent manner (P<0.05. Compared with 0μmol/L palmitic acid group, the intracellular ROS content and the expression of Plin5 increased significantly in 300μmol/L palmitic acid group (P<0.05. Compared with the control group and the Scra siRNA group, the intracellular ROS content and apoptotic rate increased significantly in Plin5 siRNA group under the action of 300μmol/L palmitic acid (P<0.05. Compared with the vehicle group, the intracellular ROS content and apoptotic rate decreased remarkably in NAC group (P<0.05. Conclusion With inhibition of oxidative stress

  12. Strategies and Experiences Using High Performance Fortran

    National Research Council Canada - National Science Library

    Shires, Dale

    2001-01-01

    .... High performance Fortran (HPF) is a relative new addition to the Fortran dialect It is an attempt to provide an efficient high-level Fortran parallel programming language for the latest generation of been debatable...

  13. Correlation between Serum High Sensitivity CRP Level and Inhospital Cardiac Events in the Patients with Unstable Angina

    Directory of Open Access Journals (Sweden)

    H. Kazerani

    2007-10-01

    Full Text Available Introduction & Objective: Several studies have been performed to evaluate correlation of serum high sensitivity CRP (hs-CRP level with the prognosis of the patients with diagnosis of unstable angina, and by now different results were reported. The aim of this study was to assess correlation between serum hs-CRP level and inhospital prognosis and cardiac events in the patients with unstable angina. Materials & Methods: This descriptive analytic study was performed from Sep 2004 till Feb 2006 in Shahid Beheshti hospital. Kermanshah, Iran. Sera were collected from 250 patients for hs-CRP measurement. Exclusion criteria were: acute ST elevation MI, non ST elevation MI, patients with history of recent infection, patients with recent trauma and patients with serum high sensitive CRP level more than 10 mg/lit. Patients were divided into two groups, first group whose serum hs-CRP level was less than 3 mg/lit and second group whose serum hs-CRP level was between 3 and 10 mg/lit. They were followed for recurrent chest pain, arrhythmias, pulmonary edema, acute myocardial infarction and in hospital death. Results were analyzed using x² and t-test. Results: Mean age were 57±7.8 and 58±11.5 years in first group and second group respectively. There was statistically significant difference in some cardiac complications such as dyspnea, duration of hospitalization, recurrent chest pain, CCU admission (p<0.001 and in hospital myocardial infarction (p=0.03, between two groups. Some complications did not have significant difference such as pulmonary edema, cardiogenic shock, arrhythmia, S3, S4 and pulmonary rates .There was no mortality in both groups. Conclusion: According to the results, we can use serum hs-CRP level for risk stratification in the patients with diagnosis of unstable angina. Obviously the patients with high serum hs-CRP level need more attention whether early invasive management help these patients, may be the matter of later studies.

  14. High Performance Grinding and Advanced Cutting Tools

    CERN Document Server

    Jackson, Mark J

    2013-01-01

    High Performance Grinding and Advanced Cutting Tools discusses the fundamentals and advances in high performance grinding processes, and provides a complete overview of newly-developing areas in the field. Topics covered are grinding tool formulation and structure, grinding wheel design and conditioning and applications using high performance grinding wheels. Also included are heat treatment strategies for grinding tools, using grinding tools for high speed applications, laser-based and diamond dressing techniques, high-efficiency deep grinding, VIPER grinding, and new grinding wheels.

  15. Strategy Guideline: High Performance Residential Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Holton, J.

    2012-02-01

    The Strategy Guideline: High Performance Residential Lighting has been developed to provide a tool for the understanding and application of high performance lighting in the home. The high performance lighting strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies to greatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner's expectations for high quality lighting.

  16. Carbon nanomaterials for high-performance supercapacitors

    OpenAIRE

    Tao Chen; Liming Dai

    2013-01-01

    Owing to their high energy density and power density, supercapacitors exhibit great potential as high-performance energy sources for advanced technologies. Recently, carbon nanomaterials (especially, carbon nanotubes and graphene) have been widely investigated as effective electrodes in supercapacitors due to their high specific surface area, excellent electrical and mechanical properties. This article summarizes the recent progresses on the development of high-performance supercapacitors bas...

  17. The effects of using high-fidelity simulators and standardized patients on the thorax, lung, and cardiac examination skills of undergraduate nursing students.

    Science.gov (United States)

    Tuzer, Hilal; Dinc, Leyla; Elcin, Melih

    2016-10-01

    Existing research literature indicates that the use of various simulation techniques in the training of physical examination skills develops students' cognitive and psychomotor abilities in a realistic learning environment while improving patient safety. The study aimed to compare the effects of the use of a high-fidelity simulator and standardized patients on the knowledge and skills of students conducting thorax-lungs and cardiac examinations, and to explore the students' views and learning experiences. A mixed-method explanatory sequential design. The study was conducted in the Simulation Laboratory of a Nursing School, the Training Center at the Faculty of Medicine, and in the inpatient clinics of the Education and Research Hospital. Fifty-two fourth-year nursing students. Students were randomly assigned to Group I and Group II. The students in Group 1 attended the thorax-lungs and cardiac examination training using a high-fidelity simulator, while the students in Group 2 using standardized patients. After the training sessions, all students practiced their skills on real patients in the clinical setting under the supervision of the investigator. Knowledge and performance scores of all students increased following the simulation activities; however, the students that worked with standardized patients achieved significantly higher knowledge scores than those that worked with the high-fidelity simulator; however, there was no significant difference in performance scores between the groups. The mean performance scores of students on real patients were significantly higher compared to the post-simulation assessment scores (psimulator in increasing the knowledge scores of students on thorax-lungs and cardiac examinations; however, practice on real patients increased performance scores of all students without any significant difference in two groups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Clinical features and risk assessment for cardiac surgery in adult congenital heart disease: Three years at a single Japanese center

    Directory of Open Access Journals (Sweden)

    Satoshi Kurokawa

    2014-04-01

    Conclusion: Cardiac surgery could be safely performed in most ACHD cases. Exercise tolerance testing can be useful in identifying patients at high risk of mortality or major complications. BNP can be valuable in predicting poor outcomes after cardiac surgery.

  19. Team Development for High Performance Management.

    Science.gov (United States)

    Schermerhorn, John R., Jr.

    1986-01-01

    The author examines a team development approach to management that creates shared commitments to performance improvement by focusing the attention of managers on individual workers and their task accomplishments. It uses the "high-performance equation" to help managers confront shared beliefs and concerns about performance and develop realistic…

  20. Delivering high performance BWR fuel reliably

    Energy Technology Data Exchange (ETDEWEB)

    Schardt, J.F. [GE Nuclear Energy, Wilmington, NC (United States)

    1998-07-01

    Utilities are under intense pressure to reduce their production costs in order to compete in the increasingly deregulated marketplace. They need fuel, which can deliver high performance to meet demanding operating strategies. GE's latest BWR fuel design, GE14, provides that high performance capability. GE's product introduction process assures that this performance will be delivered reliably, with little risk to the utility. (author)

  1. HPTA: High-Performance Text Analytics

    OpenAIRE

    Vandierendonck, Hans; Murphy, Karen; Arif, Mahwish; Nikolopoulos, Dimitrios S.

    2017-01-01

    One of the main targets of data analytics is unstructured data, which primarily involves textual data. High-performance processing of textual data is non-trivial. We present the HPTA library for high-performance text analytics. The library helps programmers to map textual data to a dense numeric representation, which can be handled more efficiently. HPTA encapsulates three performance optimizations: (i) efficient memory management for textual data, (ii) parallel computation on associative dat...

  2. Automated high-throughput measurement of body movements and cardiac activity of Xenopus tropicalis tadpoles

    Directory of Open Access Journals (Sweden)

    Kay Eckelt

    2014-07-01

    Full Text Available Xenopus tadpoles are an emerging model for developmental, genetic and behavioral studies. A small size, optical accessibility of most of their organs, together with a close genetic and structural relationship to humans make them a convenient experimental model. However, there is only a limited toolset available to measure behavior and organ function of these animals at medium or high-throughput. Herein, we describe an imaging-based platform to quantify body and autonomic movements of Xenopus tropicalis tadpoles of advanced developmental stages. Animals alternate periods of quiescence and locomotor movements and display buccal pumping for oxygen uptake from water and rhythmic cardiac movements. We imaged up to 24 animals in parallel and automatically tracked and quantified their movements by using image analysis software. Animal trajectories, moved distances, activity time, buccal pumping rates and heart beat rates were calculated and used to characterize the effects of test compounds. We evaluated the effects of propranolol and atropine, observing a dose-dependent bradycardia and tachycardia, respectively. This imaging and analysis platform is a simple, cost-effective high-throughput in vivo assay system for genetic, toxicological or pharmacological characterizations.

  3. Highly-Accelerated Real-Time Cardiac Cine MRI Using k-t SPARSE-SENSE

    Science.gov (United States)

    Feng, Li; Srichai, Monvadi B.; Lim, Ruth P.; Harrison, Alexis; King, Wilson; Adluru, Ganesh; Dibella, Edward VR.; Sodickson, Daniel K.; Otazo, Ricardo; Kim, Daniel

    2012-01-01

    For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (~2.5mm × 2.5mm) and temporal resolution (~40ms), to produce high-quality real-time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular (LV) function. In this work, we present an 8-fold accelerated real-time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE). Compared with reference, breath-hold cine MRI, our 8-fold accelerated real-time cine MRI produced significantly worse qualitative grades (1–5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both 8-fold accelerated real-time cine and breath-hold cine MRI yielded comparable LV function measurements, with coefficient of variation cine MRI with k-t SPARSE-SENSE is a promising modality for rapid imaging of myocardial function. PMID:22887290

  4. Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

    Science.gov (United States)

    Feng, Li; Srichai, Monvadi B; Lim, Ruth P; Harrison, Alexis; King, Wilson; Adluru, Ganesh; Dibella, Edward V R; Sodickson, Daniel K; Otazo, Ricardo; Kim, Daniel

    2013-07-01

    For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm(2)) and temporal resolution (∼40 ms), to produce high-quality real-time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular function. In this work, we present an eightfold accelerated real-time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE). Compared with reference, breath-hold cine MRI, our eightfold accelerated real-time cine MRI produced significantly worse qualitative grades (1-5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both eightfold accelerated real-time cine and breath-hold cine MRI yielded comparable left ventricular function measurements, with coefficient of variation cine MRI with k-t SPARSE-SENSE is a promising modality for rapid imaging of myocardial function. Copyright © 2012 Wiley Periodicals, Inc.

  5. High cardiac vagal control is related to better subjective and objective sleep quality.

    Science.gov (United States)

    Werner, Gabriela G; Ford, Brett Q; Mauss, Iris B; Schabus, Manuel; Blechert, Jens; Wilhelm, Frank H

    2015-03-01

    Cardiac vagal control (CVC) has been linked to both physical and mental health. One critical aspect of health, that has not received much attention, is sleep. We hypothesized that adults with higher CVC--operationalized by high-frequency heart rate variability (HF-HRV)--will exhibit better sleep quality assessed both subjectively (i.e., with Pittsburgh Sleep Quality Index) and objectively (i.e., with polysomnography). HF-HRV was measured in 29 healthy young women during an extended neutral film clip. Participants then underwent full polysomnography to obtain objective measures of sleep quality and HF-HRV during a night of sleep. As expected, higher resting HF-HRV was associated with higher subjective and objective sleep quality (i.e., shorter sleep latency and fewer arousals). HF-HRV during sleep (overall or separated by sleep phases) showed less consistent relationships with sleep quality. These findings indicate that high waking CVC may be a key predictor of healthy sleep. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Increased cardiac output and maximal oxygen uptake in response to ten sessions of high intensity interval training.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael M; Namm, Samantha; Fischer, Anthony; Wood, Kimi A

    2018-01-01

    Increases in maximal oxygen uptake (VO2max) are widely reported in response to completion of high intensity interval training (HIIT), yet the mechanism explaining this result is poorly understood. This study examined changes in VO2max and cardiac output (CO) in response to 10 sessions of low-volume HIIT. Participants included 30 active men and women (mean age and VO2max=22.9±5.4 years and 39.6±5.6 mL/kg/min) who performed HIIT and 30 men and women (age and VO2max=25.7±4.5 years and 40.7±5.2 mL/kg/min) who served as non-exercising controls (CON). High intensity interval training consisted of 6-10 s bouts of cycling per session at 90-110 percent peak power output (PPO) interspersed with 75 s recovery. Before and after training, progressive cycling to exhaustion was completed during which CO, stroke volume (SV), and heart rate (HR) were estimated using thoracic impedance. To confirm VO2max attainment, a verification test was completed after progressive cycling at a work rate equal to 110%PPO. Data demonstrated significant improvements in VO2max (2.71±0.63 L/min to 2.86±0.63 L/min, Psessions of HIIT is due to improvements in oxygen delivery.

  7. Defining the Intrinsic Cardiac Risks of Operations to Improve Preoperative Cardiac Risk Assessments.

    Science.gov (United States)

    Liu, Jason B; Liu, Yaoming; Cohen, Mark E; Ko, Clifford Y; Sweitzer, Bobbie J

    2018-02-01

    Current preoperative cardiac risk stratification practices group operations into broad categories, which might inadequately consider the intrinsic cardiac risks of individual operations. We sought to define the intrinsic cardiac risks of individual operations and to demonstrate how grouping operations might lead to imprecise estimates of perioperative cardiac risk. Elective operations (based on Common Procedural Terminology codes) performed from January 1, 2010 to December 31, 2015 at hospitals participating in the American College of Surgeons National Surgical Quality Improvement Program were studied. A composite measure of perioperative adverse cardiac events was defined as either cardiac arrest requiring cardiopulmonary resuscitation or acute myocardial infarction. Operations' intrinsic cardiac risks were derived from mixed-effects models while controlling for patient mix. Resultant risks were sorted into low-, intermediate-, and high-risk categories, and the most commonly performed operations within each category were identified. Intrinsic operative risks were also examined using a representative grouping of operations to portray within-group variation. Sixty-six low, 30 intermediate, and 106 high intrinsic cardiac risk operations were identified. Excisional breast biopsy had the lowest intrinsic cardiac risk (overall rate, 0.01%; odds ratio, 0.11; 95% CI, 0.02 to 0.25) relative to the average, whereas aorto-bifemoral bypass grafting had the highest (overall rate, 4.1%; odds ratio, 6.61; 95% CI, 5.54 to 7.90). There was wide variation in the intrinsic cardiac risks of operations within the representative grouping (median odds ratio, 1.40; interquartile range, 0.88 to 2.17). A continuum of intrinsic cardiac risk exists among operations. Grouping operations into broad categories inadequately accounts for the intrinsic cardiac risk of individual operations.

  8. Cross-sectional study of high-sensitivity cardiac troponins T and I in a hospital and community outpatient setting.

    Science.gov (United States)

    Potter, Julia M; Simpson, Aaron J; Kerrigan, Jennifer; Southcott, Emma; Salib, Marie M; Koerbin, Gus; Hickman, Peter E

    2017-02-01

    Cardiac troponins are specific for the heart, but not for the acute coronary syndrome. We wanted to assess how common elevated cardiac troponin concentrations were, in a population with significant non-cardiac disease. We measured both hs-cTnT and hs-cTnI on all samples submitted to the laboratory during one 24h period, and assessed the magnitude of the cTn concentration with the location and severity of disease of the patient. Community patients and patients from the maternity ward had the lowest cTn concentrations with results above the 99th percentile being only 0-2% of the total. As expected, the highest proportion of results >99th percentile came from Coronary Care and Intensive Care. However, substantial numbers of persons on Medical and Surgical wards, without a primary diagnosis of cardiac disease, also had cTn >99th percentile. Particularly for cTnT, there was a highly significant odds ratio predicting mortality when results above and below the 99th percentile were compared. Significant illnesses apart from the acute coronary syndrome are important causes of a rise in cTn to above the 99th percentile, and appear to reflect the total body burden of disease. Even when the high hs-cTn concentration is not due to the acute coronary syndrome, there is a significant association with all-cause mortality. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. High sensitivity cardiac troponin I detection in physiological environment using AlGaN/GaN High Electron Mobility Transistor (HEMT) Biosensors.

    Science.gov (United States)

    Sarangadharan, Indu; Regmi, Abiral; Chen, Yen-Wen; Hsu, Chen-Pin; Chen, Pei-Chi; Chang, Wen-Hsin; Lee, Geng-Yen; Chyi, Jen-Inn; Shiesh, Shu-Chu; Lee, Gwo-Bin; Wang, Yu-Lin

    2018-02-15

    In this study, we report the development of a high sensitivity assay for the detection of cardiac troponin I using electrical double layer gated high field AlGaN/GaN HEMT biosensor. The unique gating mechanism overcomes the drawback of charge screening seen in traditional FET based biosensors, allowing detection of target proteins in physiological solutions without sample processing steps. Troponin I specific antibody and aptamer are used as receptors. The tests carried out using purified protein solution and clinical serum samples depict high sensitivity, specificity and wide dynamic range (0.006-148ng/mL). No additional wash or sample pre-treatment steps are required, which greatly simplifies the biosensor system. The miniaturized HEMT chip is packaged in a polymer substrate and easily integrated with a portable measurement unit, to carry out quantitative troponin I detection in serum samples with < 2µl sample volume in 5min. The integrated prototype biosensor unit demonstrates the potential of the method as a rapid, inexpensive, high sensitivity CVD biomarker assay. The highly simplified protocols and enhanced sensor performance make our biosensor an ideal choice for point of care diagnostics and personal healthcare systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Evaluation of highly accelerated real-time cardiac cine MRI in tachycardia.

    Science.gov (United States)

    Bassett, Elwin C; Kholmovski, Eugene G; Wilson, Brent D; DiBella, Edward V R; Dosdall, Derek J; Ranjan, Ravi; McGann, Christopher J; Kim, Daniel

    2014-02-01

    Electrocardiogram (ECG)-gated breath-hold cine MRI is considered to be the gold standard test for the assessment of cardiac function. However, it may fail in patients with arrhythmia, impaired breath-hold capacity and poor ECG gating. Although ungated real-time cine MRI may mitigate these problems, commercially available real-time cine MRI pulse sequences using parallel imaging typically yield relatively poor spatiotemporal resolution because of their low image acquisition efficiency. As an extension of our previous work, the purpose of this study was to evaluate the diagnostic quality and accuracy of eight-fold-accelerated real-time cine MRI with compressed sensing (CS) for the quantification of cardiac function in tachycardia, where it is challenging for real-time cine MRI to provide sufficient spatiotemporal resolution. We evaluated the performances of eight-fold-accelerated cine MRI with CS, three-fold-accelerated real-time cine MRI with temporal generalized autocalibrating partially parallel acquisitions (TGRAPPA) and ECG-gated breath-hold cine MRI in 21 large animals with tachycardia (mean heart rate, 104 beats per minute) at 3T. For each cine MRI method, two expert readers evaluated the diagnostic quality in four categories (image quality, temporal fidelity of wall motion, artifacts and apparent noise) using a Likert scale (1-5, worst to best). One reader evaluated the left ventricular functional parameters. The diagnostic quality scores were significantly different between the three cine pulse sequences, except for the artifact level between CS and TGRAPPA real-time cine MRI. Both ECG-gated breath-hold cine MRI and eight-fold accelerated real-time cine MRI yielded all four scores of ≥ 3.0 (acceptable), whereas three-fold-accelerated real-time cine MRI yielded all scores below 3.0, except for artifact (3.0). The left ventricular ejection fraction (LVEF) measurements agreed better between ECG-gated cine MRI and eight-fold-accelerated real-time cine MRI

  11. High intensity interval training (HIIT) improves resting blood pressure, metabolic (MET) capacity and heart rate reserve without compromising cardiac function in sedentary aging men.

    Science.gov (United States)

    Grace, Fergal; Herbert, Peter; Elliott, Adrian D; Richards, Jo; Beaumont, Alexander; Sculthorpe, Nicholas F

    2017-05-13

    This study examined a programme of pre-conditioning exercise with subsequent high intensity interval training (HIIT) on blood pressure, echocardiography, cardiac strain mechanics and maximal metabolic (MET) capacity in sedentary (SED) aging men compared with age matched masters athletes (LEX). Using a STROBE compliant observational design, 39 aging male participants (SED; n=22, aged 62.7±5.2yrs) (LEX; n=17, aged=61.1±5.4yrs) were recruited to a study that necessitated three distinct assessment phases; enrolment (Phase A), following pre-conditioning exercise in SED (Phase B), then following 6weeks of HIIT performed once every five days by both groups before reassessment (Phase C). Hemodynamic, echocardiographic and cardiac strain mechanics were obtained at rest and maximal cardiorespiratory and chronotropic responses were obtained at each measurement phase. The training intervention improved systolic, mean arterial blood pressure, rate pressure product and heart rate reserve (each PHIIT. Echocardiography and cardiac strain measures were unremarkable apart from trivial increase to intra-ventricular septum diastole (IVSd) (PHIIT. A programme of preconditioning exercise with HIIT induces clinically relevant improvements in blood pressure, rate pressure product and encourages recovery of heart rate reserve in SED, while improving maximal MET capacity in both SED and LEX without inducing any pathological cardiovascular remodeling. These data add to the emerging repute of HIIT as a safe and promising exercise prescription to improve cardiovascular function and metabolic capacity in sedentary aging. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Strategy Guideline. Partnering for High Performance Homes

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, Duncan [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-01-01

    High performance houses require a high degree of coordination and have significant interdependencies between various systems in order to perform properly, meet customer expectations, and minimize risks for the builder. Responsibility for the key performance attributes is shared across the project team and can be well coordinated through advanced partnering strategies. For high performance homes, traditional partnerships need to be matured to the next level and be expanded to all members of the project team including trades, suppliers, manufacturers, HERS raters, designers, architects, and building officials as appropriate. This guide is intended for use by all parties associated in the design and construction of high performance homes. It serves as a starting point and features initial tools and resources for teams to collaborate to continually improve the energy efficiency and durability of new houses.

  13. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    OpenAIRE

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-01-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by fac...

  14. Radionuclide techniques in studies of cardiac performance and circulatory changes during antihypertensive treatment

    International Nuclear Information System (INIS)

    Falch, D.K.

    A non-invasive radionuclide technique to determine variables in the systematic and pulmonary circulation useful in out- patient studies is described. Indium 113m chloride was chosen as the tracer, and iodine 125 iothalamate may be used for simultaneous determination of the glomerular filtration rate. The counting geometry is discussed at some length. The errors of the method and its reproducability seem to be acceptable. The method was tested on two groups of healthy subjects, one of which was composed of well-trained athletes, and two groups of patients, one with chronic cardiac insufficiency, the other with primary hypertension. Tables are presented giving hemodynamic data for these groups. It is concluded that the technique gives some useful data, but that further refinement and supplementation is necessary to obtain a guidance in drug therapy. (JIW)

  15. Cardiac adaptations to high-intensity aerobic training in premenopausal and recent postmenopausal women

    DEFF Research Database (Denmark)

    Egelund, Jon; Jørgensen, Peter Godsk; Mandrup, Camilla M

    2017-01-01

    and after a 12-week period of high-intensity aerobic cycle training. LV internal diastolic diameter and LV mass were similar in the 2 groups at baseline and increased by ≈2% to 8% (P=0.04-0.0007) with training in both groups. Left atrial end-diastolic and end-systolic volumes were similar for both groups......BACKGROUND: We examined the role of menopause on cardiac dimensions and function and assessed the efficacy of exercise training before and after menopause. METHODS AND RESULTS: Two groups of healthy premenopausal (n=36, 49.4±0.3 years) and postmenopausal (n=37, 53.5±0.5 years) women with no history...... and increased by 23% to 36% (P=0.0006-0.0001) with training. Systolic function assessed by mean global strain was similar in both groups at baseline and increased by ≈8% (P=0.0004) with training in the postmenopausal group. LV displacement increased by ≈3% (P=0.04) in the premenopausal women only. Diastolic...

  16. High-performance ceramics. Fabrication, structure, properties

    International Nuclear Information System (INIS)

    Petzow, G.; Tobolski, J.; Telle, R.

    1996-01-01

    The program ''Ceramic High-performance Materials'' pursued the objective to understand the chaining of cause and effect in the development of high-performance ceramics. This chain of problems begins with the chemical reactions for the production of powders, comprises the characterization, processing, shaping and compacting of powders, structural optimization, heat treatment, production and finishing, and leads to issues of materials testing and of a design appropriate to the material. The program ''Ceramic High-performance Materials'' has resulted in contributions to the understanding of fundamental interrelationships in terms of materials science, which are summarized in the present volume - broken down into eight special aspects. (orig./RHM)

  17. High Burnup Fuel Performance and Safety Research

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Je Keun; Lee, Chan Bok; Kim, Dae Ho (and others)

    2007-03-15

    The worldwide trend of nuclear fuel development is to develop a high burnup and high performance nuclear fuel with high economies and safety. Because the fuel performance evaluation code, INFRA, has a patent, and the superiority for prediction of fuel performance was proven through the IAEA CRP FUMEX-II program, the INFRA code can be utilized with commercial purpose in the industry. The INFRA code was provided and utilized usefully in the universities and relevant institutes domesticallly and it has been used as a reference code in the industry for the development of the intrinsic fuel rod design code.

  18. Imaging in cardiac mass lesions

    International Nuclear Information System (INIS)

    Mundinger, A.; Gruber, H.P.; Dinkel, E.; Geibel, A.; Beck, A.; Wimmer, B.; Schlosser, V.

    1992-01-01

    In 26 patients with cardiac mass lesions confirmed by surgery, diagnostic imaging was performed preoperatively by means of two-dimensional echocardiography (26 patients), angiography (12 patients), correlative computed tomography (CT, 8 patients), and magnetic resonance imaging (MRI, 3 patients). Two-dimensional echocardiography correctly identified the cardiac masses in all patients. Angiography missed two of 12 cardiac masses; CT missed one of eight. MRI identified three of three cardiac masses. Although the sensitivity of two-dimensional echocardiography was high (100%), all methods lacked specificity. None of the methods allowed differentiation between myxoma (n=13) and thrombus (n=7). Malignancy of the lesions was successfully predicted by noninvasive imaging methods in all six patients. However, CT and MRI provided additional information concerning cardiac mural infiltration, pericardial involvement, and extracardiac tumor extension, and should be integrated within a preoperative imaging strategy. Thus two-dimensional echocardiography is the method of choice for primary assessment of patients with suspected cardiac masses. Further preoperative imaging by CT or MRI can be limited to patients with malignancies suspected on the grounds of pericardial effusion or other clinical results. (author)

  19. Hypothyroidism leads to increased collagen-based stiffness and re-expression of large cardiac titin isoforms with high compliance.

    Science.gov (United States)

    Wu, Yiming; Peng, Jun; Campbell, Kenneth B; Labeit, Siegfried; Granzier, Henk

    2007-01-01

    Because long-term hypothyroidism results in diastolic dysfunction, we investigated myocardial passive stiffness in hypothyroidism and focused on the possible role of titin, an important determinant of diastolic stiffness. A rat model of hypothyroidism was used, obtained by administering propylthiouracil (PTU) for times that varied from 1 month (short-term) to 4 months (long-term). Titin expression was determined by transcript analysis, gel electrophoresis and immunoelectron microscopy. Diastolic function was measured at the isolated heart, skinned muscle, and cardiac myocyte levels. We found that hypothyroidism resulted in expression of a large titin isoform, the abundance of which gradually increased with time to become the most dominant isoform in long-term hypothyroid rats. This isoform co-migrates on high-resolution gels with fetal cardiac titin. Transcript analysis on myocardium of long-term PTU rats, provided evidence for expression of additional PEVK and Ig domain exons, similar to what has been described in fetal myocardium. Consistent with the expression of a large titin isoform, titin-based restoring and passive forces were significantly reduced in single cardiac myocytes and muscle strips of long-term hypothyroid rats. Overall muscle stiffness and LV diastolic wall stiffness were increased, however, due to increased collagen-based stiffness. We conclude that long term hypothyroidism triggers expression of a large cardiac titin isoform and that the ensuing reduction in titin-based passive stiffness functions as a compensatory mechanism to reduce LV wall stiffness.

  20. Low to high frequency ratio of heart rate variability spectra fails to describe sympatho-vagal balance in cardiac patients.

    Science.gov (United States)

    Milicević, Goran

    2005-06-01

    Heart rate variability (HRV) reflects an influence of autonomic nervous system on heart work. In healthy subjects, ratio between low and high frequency components (LF/HF ratio) of HRV spectra represents a measure of sympatho-vagal balance. The ratio was defined by the authorities as an useful clinical tool, but it seems that it fails to summarise sympatho-vagal balance in a clinical setting. Value of the method was re-evaluated in several categories of cardiac patients. HRV was analysed from 24-hour Holter ECGs in 132 healthy subjects, and 2159 cardiac patients dichotomised by gender, median of age, diagnosis of myocardial infarction or coronary artery surgery, left ventricular systolic function and divided by overall HRV into several categories. In healthy subjects, LF/HF ratio correlated with overall HRV negatively, as expected. The paradoxical finding was obtained in cardiac patients; the lower the overall HRV and the time-domain indices of vagal modulation activity were the lower the LF/HF ratio was. If used as a measure of sympatho-vagal balance, long-term recordings of LF/HF ratio contradict to clinical finding and time-domain HRV indices in cardiac patients. The ratio cannot therefore be used as a reliable marker of autonomic activity in a clinical setting.

  1. ADVANCED HIGH PERFORMANCE SOLID WALL BLANKET CONCEPTS

    International Nuclear Information System (INIS)

    WONG, CPC; MALANG, S; NISHIO, S; RAFFRAY, R; SAGARA, S

    2002-01-01

    OAK A271 ADVANCED HIGH PERFORMANCE SOLID WALL BLANKET CONCEPTS. First wall and blanket (FW/blanket) design is a crucial element in the performance and acceptance of a fusion power plant. High temperature structural and breeding materials are needed for high thermal performance. A suitable combination of structural design with the selected materials is necessary for D-T fuel sufficiency. Whenever possible, low afterheat, low chemical reactivity and low activation materials are desired to achieve passive safety and minimize the amount of high-level waste. Of course the selected fusion FW/blanket design will have to match the operational scenarios of high performance plasma. The key characteristics of eight advanced high performance FW/blanket concepts are presented in this paper. Design configurations, performance characteristics, unique advantages and issues are summarized. All reviewed designs can satisfy most of the necessary design goals. For further development, in concert with the advancement in plasma control and scrape off layer physics, additional emphasis will be needed in the areas of first wall coating material selection, design of plasma stabilization coils, consideration of reactor startup and transient events. To validate the projected performance of the advanced FW/blanket concepts the critical element is the need for 14 MeV neutron irradiation facilities for the generation of necessary engineering design data and the prediction of FW/blanket components lifetime and availability

  2. Adequate performance of cardiopulmonary resuscitation techniques during simulated cardiac arrest over and under protective equipment in football.

    Science.gov (United States)

    Waninger, Kevin N; Goodbred, Andrew; Vanic, Keith; Hauth, John; Onia, Joshua; Stoltzfus, Jill; Melanson, Scott

    2014-07-01

    To investigate (1) cardiopulmonary resuscitation (CPR) adequacy during simulated cardiac arrest of equipped football players and (2) whether protective football equipment impedes CPR performance measures. Exploratory crossover study performed on Laerdal SimMan 3 G interactive manikin simulator. Temple University/St Luke's University Health Network Regional Medical School Simulation Laboratory. Thirty BCLS-certified ATCs and 6 ACLS-certified emergency department technicians. Subjects were given standardized rescuer scenarios to perform three 2-minute sequences of compression-only CPR. Baseline CPR sequences were captured on each subject. Experimental conditions included 2-minute sequences of CPR either over protective football shoulder pads or under unlaced pads. Subjects were instructed to adhere to 2010 American Heart Association guidelines (initiation of compressions alone at 100/min to 51 mm). Dependent variables included average compression depth, average compression rate, percentage of time chest wall recoiled, and percentage of hands-on contact during compressions. Differences between subject groups were not found to be statistically significant, so groups were combined (n = 36) for analysis of CPR compression adequacy. Compression depth was deeper under shoulder pads than over (P = 0.02), with mean depths of 36.50 and 31.50 mm, respectively. No significant difference was found with compression rate or chest wall recoil. Chest compression depth is significantly decreased when performed over shoulder pads, while there is no apparent effect on rate or chest wall recoil. Although the clinical outcomes from our observed 15% difference in compression depth are uncertain, chest compression under the pads significantly increases the depth of compressions and more closely approaches American Heart Association guidelines for chest compression depth in cardiac arrest.

  3. Antioxidant catalase rescues against high fat diet-induced cardiac dysfunction via an IKKβ-AMPK-dependent regulation of autophagy.

    Science.gov (United States)

    Liang, Lei; Shou, Xi-Ling; Zhao, Hai-Kang; Ren, Gu-Qun; Wang, Jian-Bang; Wang, Xi-Hui; Ai, Wen-Ting; Maris, Jackie R; Hueckstaedt, Lindsay K; Ma, Ai-Qun; Zhang, Yingmei

    2015-02-01

    Autophagy, a conservative degradation process for long-lived and damaged proteins, participates in a variety of biological processes including obesity. However, the precise mechanism of action behind obesity-induced changes in autophagy still remains elusive. This study was designed to examine the role of the antioxidant catalase in high fat diet-induced changes in cardiac geometry and function as well as the underlying mechanism of action involved with a focus on autophagy. Wild-type (WT) and transgenic mice with cardiac overexpression of catalase were fed low or high fat diet for 20 weeks prior to assessment of myocardial geometry and function. High fat diet intake triggered obesity, hyperinsulinemia, and hypertriglyceridemia, the effects of which were unaffected by catalase transgene. Myocardial geometry and function were compromised with fat diet intake as manifested by cardiac hypertrophy, enlarged left ventricular end systolic and diastolic diameters, fractional shortening, cardiomyocyte contractile capacity and intracellular Ca²⁺ mishandling, the effects of which were ameliorated by catalase. High fat diet intake promoted reactive oxygen species production and suppressed autophagy in the heart, the effects of which were attenuated by catalase. High fat diet intake dampened phosphorylation of inhibitor kappa B kinase β(IKKβ), AMP-activated protein kinase (AMPK) and tuberous sclerosis 2 (TSC2) while promoting phosphorylation of mTOR, the effects of which were ablated by catalase. In vitro study revealed that palmitic acid compromised cardiomyocyte autophagy and contractile function in a manner reminiscent of fat diet intake, the effect of which was significantly alleviated by inhibition of IKKβ, activation of AMPK and induction of autophagy. Taken together, our data revealed that the antioxidant catalase counteracts against high fat diet-induced cardiac geometric and functional anomalies possibly via an IKKβ-AMPK-dependent restoration of myocardial

  4. High performance liquid chromatographic determination of ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-08

    ) high performance liquid chromatography (HPLC) grade .... applications. These are important requirements if the reagent is to be applicable to on-line pre or post column derivatisation in a possible automation of the analytical.

  5. Analog circuit design designing high performance amplifiers

    CERN Document Server

    Feucht, Dennis

    2010-01-01

    The third volume Designing High Performance Amplifiers applies the concepts from the first two volumes. It is an advanced treatment of amplifier design/analysis emphasizing both wideband and precision amplification.

  6. High-performance computing using FPGAs

    CERN Document Server

    Benkrid, Khaled

    2013-01-01

    This book is concerned with the emerging field of High Performance Reconfigurable Computing (HPRC), which aims to harness the high performance and relative low power of reconfigurable hardware–in the form Field Programmable Gate Arrays (FPGAs)–in High Performance Computing (HPC) applications. It presents the latest developments in this field from applications, architecture, and tools and methodologies points of view. We hope that this work will form a reference for existing researchers in the field, and entice new researchers and developers to join the HPRC community.  The book includes:  Thirteen application chapters which present the most important application areas tackled by high performance reconfigurable computers, namely: financial computing, bioinformatics and computational biology, data search and processing, stencil computation e.g. computational fluid dynamics and seismic modeling, cryptanalysis, astronomical N-body simulation, and circuit simulation.     Seven architecture chapters which...

  7. Embedded High Performance Scalable Computing Systems

    National Research Council Canada - National Science Library

    Ngo, David

    2003-01-01

    The Embedded High Performance Scalable Computing Systems (EHPSCS) program is a cooperative agreement between Sanders, A Lockheed Martin Company and DARPA that ran for three years, from Apr 1995 - Apr 1998...

  8. Gradient High Performance Liquid Chromatography Method ...

    African Journals Online (AJOL)

    Purpose: To develop a gradient high performance liquid chromatography (HPLC) method for the simultaneous determination of phenylephrine (PHE) and ibuprofen (IBU) in solid ..... nimesulide, phenylephrine. Hydrochloride, chlorpheniramine maleate and caffeine anhydrous in pharmaceutical dosage form. Acta Pol.

  9. Highlighting High Performance: Whitman Hanson Regional High School; Whitman, Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    2006-06-01

    This brochure describes the key high-performance building features of the Whitman-Hanson Regional High School. The brochure was paid for by the Massachusetts Technology Collaborative as part of their Green Schools Initiative. High-performance features described are daylighting and energy-efficient lighting, indoor air quality, solar and wind energy, building envelope, heating and cooling systems, water conservation, and acoustics. Energy cost savings are also discussed.

  10. High performance computing in Windows Azure cloud

    OpenAIRE

    Ambruš, Dejan

    2013-01-01

    High performance, security, availability, scalability, flexibility and lower costs of maintenance have essentially contributed to the growing popularity of cloud computing in all spheres of life, especially in business. In fact cloud computing offers even more than this. With usage of virtual computing clusters a runtime environment for high performance computing can be efficiently implemented also in a cloud. There are many advantages but also some disadvantages of cloud computing, some ...

  11. High-performance computing — an overview

    Science.gov (United States)

    Marksteiner, Peter

    1996-08-01

    An overview of high-performance computing (HPC) is given. Different types of computer architectures used in HPC are discussed: vector supercomputers, high-performance RISC processors, various parallel computers like symmetric multiprocessors, workstation clusters, massively parallel processors. Software tools and programming techniques used in HPC are reviewed: vectorizing compilers, optimization and vector tuning, optimization for RISC processors; parallel programming techniques like shared-memory parallelism, message passing and data parallelism; and numerical libraries.

  12. Governance among Malaysian high performing companies

    Directory of Open Access Journals (Sweden)

    Asri Marsidi

    2016-07-01

    Full Text Available Well performed companies have always been linked with effective governance which is generally reflected through effective board of directors. However many issues concerning the attributes for effective board of directors remained unresolved. Nowadays diversity has been perceived as able to influence the corporate performance due to the likelihood of meeting variety of needs and demands from diverse customers and clients. The study therefore aims to provide a fundamental understanding on governance among high performing companies in Malaysia.

  13. High-performance OPCPA laser system

    International Nuclear Information System (INIS)

    Zuegel, J.D.; Bagnoud, V.; Bromage, J.; Begishev, I.A.; Puth, J.

    2006-01-01

    Optical parametric chirped-pulse amplification (OPCPA) is ideally suited for amplifying ultra-fast laser pulses since it provides broadband gain across a wide range of wavelengths without many of the disadvantages of regenerative amplification. A high-performance OPCPA system has been demonstrated as a prototype for the front end of the OMEGA Extended Performance (EP) Laser System. (authors)

  14. High-performance OPCPA laser system

    Energy Technology Data Exchange (ETDEWEB)

    Zuegel, J.D.; Bagnoud, V.; Bromage, J.; Begishev, I.A.; Puth, J. [Rochester Univ., Lab. for Laser Energetics, NY (United States)

    2006-06-15

    Optical parametric chirped-pulse amplification (OPCPA) is ideally suited for amplifying ultra-fast laser pulses since it provides broadband gain across a wide range of wavelengths without many of the disadvantages of regenerative amplification. A high-performance OPCPA system has been demonstrated as a prototype for the front end of the OMEGA Extended Performance (EP) Laser System. (authors)

  15. Comparing Dutch and British high performing managers

    NARCIS (Netherlands)

    Waal, A.A. de; Heijden, B.I.J.M. van der; Selvarajah, C.; Meyer, D.

    2016-01-01

    National cultures have a strong influence on the performance of organizations and should be taken into account when studying the traits of high performing managers. At the same time, many studies that focus upon the attributes of successful managers show that there are attributes that are similar

  16. Value of improved lipid control in patients at high risk for adverse cardiac events.

    Science.gov (United States)

    Jena, Anupam B; Blumenthal, Daniel M; Stevens, Warren; Chou, Jacquelyn W; Ton, Thanh G N; Goldman, Dana P

    2016-06-01

    Lipid-lowering therapy (LLT) is suboptimally used in patients with hyperlipidemia in the 2 highest statin benefit groups (SBGs), as categorized by the American College of Cardiology and the American Heart Association. This study estimated the social value of reducing low-density lipoprotein cholesterol (LDL-C) levels by 50% for patients in SBGs 1 and 2 who have been treated with standard LLT but have not reached LDL-C goal, as well as the potential value of PCSK9 inhibitors for patients in these groups. Simulation model. We used National Health and Nutrition Examination Surveys (NHANES) and US Census data to project the population of SBGs 1 and 2 in the time period 2015 to 2035. We used insurance claims data to estimate incidence rates of major adverse cardiac events (MACEs), and NHANES with National Vital Statistics data to estimate cardiovascular disease mortality rates. Using established associations between LDL-C and MACE risk, we estimated the value of reducing LDL-C levels by 50%. We incorporated results from a meta-analysis to estimate the value of PSCK9 inhibitors. Among those treated with LLT with LDL-C > 70 mg/dL in SBGs 1 and 2, the cumulative value of reducing LDL-C levels by 50% would be $2.9 trillion from 2015 to 2035, resulting primarily from 1.6 million deaths averted. The cumulative value of PCSK9 inhibitors would range from $3.4 trillion to $5.1 trillion (1.9-2.8 million deaths averted), or $12,000 to $17,000 per patient-year of treatment. Lowering LDL-C in high-risk patients with hyperlipidemia has enormous potential social value. For patients in these high-risk groups, PCSK9 inhibitors may have considerable net value depending on the final prices payers ultimately select.

  17. Serial measurements of high sensitive cardiac troponin I in patients with acutely decompensated heart failure treated with carperitide or nitrates.

    Science.gov (United States)

    Sato, Yukihito; Nishi, Kiyoto; Saijo, Sayaka; Tanada, Yohei; Goto, Taisuke; Takahashi, Naoki; Yamamoto, Erika; Fukuhara, Rei; Miyamoto, Tadashi; Taniguchi, Ryoji; Fujiwara, Hisayoshi; Takatsu, Yoshiki

    2010-07-01

    In patients with acutely decompensated heart failure (ADHF), elevated serum concentration of cardiac troponin is an independent predictor of adverse cardiac events. In ADHF with a preserved systolic blood pressure, treatment with intravenous vasodilator is recommended. However, the effect of vasodilators on troponin concentrations has not been elucidated well. Serial high sensitive cardiac troponin I (hs-TnI) was measured in 36 patients presenting with ADHF and preserved systolic blood pressure, of whom 20 were treated with atrial natriuretic peptide (ANP) and 16 with nitrates. The concentrations of hs-TnI ranged from 0.069+/-0.114ng/ml at baseline to 0.076+/-0.121ng/ml at 5h, 0.062+/-0.106ng/ml at 1 day, and 0.056+/-0.089ng/ml at day 7 (n=36,ns). The relative change in hs-TnI between baseline and at 5h, day 1 and day 7 were 1.13+/-0.43, 0.95+/-0.44 and 0.93+/-0.64 in patients treated with ANP, and 1.02+/-0.19, 0.95+/-0.31 and 1.19+/-1.38 in patients treated with nitrates (ns; ANP versus nitrates). On day 7, a hs-TnI change, >20% decrease from baseline, was observed in 55% patients with ANP versus 56% patients with nitrates (ns). The cardiac event rates were similar in both groups. In ADHF patients with preserved systolic blood pressure, the administration of intravenous vasodilators did not decrease hs-TnI over the first 7 days. Treatments with ANP and nitrates were associated with similar short-term decreases in hs-TnI and long-term adverse cardiac events. Copyright 2010 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  18. A bi-ventricular cardiac atlas built from 1000+ high resolution MR images of healthy subjects and an analysis of shape and motion.

    Science.gov (United States)

    Bai, Wenjia; Shi, Wenzhe; de Marvao, Antonio; Dawes, Timothy J W; O'Regan, Declan P; Cook, Stuart A; Rueckert, Daniel

    2015-12-01

    Atlases encode valuable anatomical and functional information from a population. In this work, a bi-ventricular cardiac atlas was built from a unique data set, which consists of high resolution cardiac MR images of 1000+ normal subjects. Based on the atlas, statistical methods were used to study the variation of cardiac shapes and the distribution of cardiac motion across the spatio-temporal domain. We have shown how statistical parametric mapping (SPM) can be combined with a general linear model to study the impact of gender and age on regional myocardial wall thickness. Finally, we have also investigated the influence of the population size on atlas construction and atlas-based analysis. The high resolution atlas, the statistical models and the SPM method will benefit more studies on cardiac anatomy and function analysis in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. High Performance Work Systems for Online Education

    Science.gov (United States)

    Contacos-Sawyer, Jonna; Revels, Mark; Ciampa, Mark

    2010-01-01

    The purpose of this paper is to identify the key elements of a High Performance Work System (HPWS) and explore the possibility of implementation in an online institution of higher learning. With the projected rapid growth of the demand for online education and its importance in post-secondary education, providing high quality curriculum, excellent…

  20. Teacher Accountability at High Performing Charter Schools

    Science.gov (United States)

    Aguirre, Moises G.

    2016-01-01

    This study will examine the teacher accountability and evaluation policies and practices at three high performing charter schools located in San Diego County, California. Charter schools are exempted from many laws, rules, and regulations that apply to traditional school systems. By examining the teacher accountability systems at high performing…

  1. Advanced high performance solid wall blanket concepts

    International Nuclear Information System (INIS)

    Wong, C.P.C.; Malang, S.; Nishio, S.; Raffray, R.; Sagara, A.

    2002-01-01

    First wall and blanket (FW/blanket) design is a crucial element in the performance and acceptance of a fusion power plant. High temperature structural and breeding materials are needed for high thermal performance. A suitable combination of structural design with the selected materials is necessary for D-T fuel sufficiency. Whenever possible, low afterheat, low chemical reactivity and low activation materials are desired to achieve passive safety and minimize the amount of high-level waste. Of course the selected fusion FW/blanket design will have to match the operational scenarios of high performance plasma. The key characteristics of eight advanced high performance FW/blanket concepts are presented in this paper. Design configurations, performance characteristics, unique advantages and issues are summarized. All reviewed designs can satisfy most of the necessary design goals. For further development, in concert with the advancement in plasma control and scrape off layer physics, additional emphasis will be needed in the areas of first wall coating material selection, design of plasma stabilization coils, consideration of reactor startup and transient events. To validate the projected performance of the advanced FW/blanket concepts the critical element is the need for 14 MeV neutron irradiation facilities for the generation of necessary engineering design data and the prediction of FW/blanket components lifetime and availability

  2. Improved coronary in-stent visualization using a combined high-resolution kernel and a hybrid iterative reconstruction technique at 256-slice cardiac CT—Pilot study

    International Nuclear Information System (INIS)

    Oda, Seitaro; Utsunomiya, Daisuke; Funama, Yoshinori; Takaoka, Hiroko; Katahira, Kazuhiro; Honda, Keiichi; Noda, Katsuo; Oshima, Shuichi; Yamashita, Yasuyuki

    2013-01-01

    Objectives: To investigate the diagnostic performance of 256-slice cardiac CT for the evaluation of the in-stent lumen by using a hybrid iterative reconstruction (HIR) algorithm combined with a high-resolution kernel. Methods: This study included 28 patients with 28 stents who underwent cardiac CT. Three different reconstruction images were obtained with: (1) a standard filtered back projection (FBP) algorithm with a standard cardiac kernel (CB), (2) an FBP algorithm with a high-resolution cardiac kernel (CD), and (3) an HIR algorithm with the CD kernel. We measured image noise and kurtosis and used receiver operating characteristics analysis to evaluate observer performance in the detection of in-stent stenosis. Results: Image noise with FBP plus the CD kernel (80.2 ± 15.5 HU) was significantly higher than with FBP plus the CB kernel (28.8 ± 4.6 HU) and HIR plus the CD kernel (36.1 ± 6.4 HU). There was no significant difference in the image noise between FBP plus the CB kernel and HIR plus the CD kernel. Kurtosis was significantly better with the CD- than the CB kernel. The kurtosis values obtained with the CD kernel were not significantly different between the FBP- and HIR reconstruction algorithms. The areas under the receiver operating characteristics curves with HIR plus the CD kernel were significantly higher than with FBP plus the CB- or the CD kernel. The difference between FBP plus the CB- or the CD kernel was not significant. The average sensitivity, specificity, and positive and negative predictive value for the detection of in-stent stenosis were 83.3, 50.0, 33.3, and 91.6% for FBP plus the CB kernel, 100, 29.6, 40.0, and 100% for FBP plus the CD kernel, and 100, 54.5, 40.0, and 100% for HIR plus the CD kernel. Conclusions: The HIR algorithm combined with the high-resolution kernel significantly improved diagnostic performance in the detection of in-stent stenosis

  3. The Effect of a High-Protein Diet and Exercise on Cardiac AQP7 and GLUT4 Gene Expression.

    Science.gov (United States)

    Palabiyik, Orkide; Karaca, Aziz; Taştekin, Ebru; Yamasan, Bilge Eren; Tokuç, Burcu; Sipahi, Tammam; Vardar, Selma Arzu

    2016-10-01

    High-protein (HP) diets are commonly consumed by athletes despite their potential health hazard, which is postulated to enforce a negative effect on bone and renal health. However, its effects on heart have not been known yet. Aquaporin-7 (AQP7) is an aquaglyceroporin that facilitates glycerol and water transport. Glycerol is an important cardiac energy production substrate, especially during exercise, in conjunction with fatty acids and glucose. Glucose transporter 4 (GLUT4) is an insulin-sensitive glucose transporter in heart. We aimed to investigate the effect of HPD on AQP7 and GLUT4 levels in the rat heart subjected to exercise. Male Sprague-Dawley rats were divided into control (n = 12), exercise (E) training (n = 10), HPD (n = 12), and HPD-E training (n = 9) groups. The HPD groups were fed a 45 % protein-containing diet 5 weeks. The HPD-E and E groups were performed the treadmill exercise during the 5-week study period. Real-time polymerase chain reaction and immunohistochemistry techniques were used to determine the gene expression and localization of AQP7 and GLUT4 in heart tissue. Results of relative gene expression were calculated by the 'Pfaffl' mathematical method using the REST program. Differences in AQP7 and GLUT4 gene expression were expressed as fold change compared to the control group. Heart weight/tibia ratio and ventricular wall thickness were evaluated as markers of cardiac hypertrophy. Further, serum glucose, glycerol, and insulin levels were also measured. AQP7 gene expression was found to be increased in the E (3.47-fold, p protein expression was also increased in the HPD and HPD-E groups (p protein expression was significantly increased in the E, HPD, and HPD-E groups compared to the control group (p = 0.024, p protein diet groups (C and E). Serum insulin levels were higher for HPD groups compared with the normal-protein diet groups (p < 0.001), whereas no differences were observed between the exercise and sedentary

  4. Modeling and analysis of dynamic scintigraphic data for measurement of cardiac perfusion and performance

    International Nuclear Information System (INIS)

    Twieg, D.B.

    1977-01-01

    Clinical scintigraphy is the technique of imaging the distributions of gamma-ray-emitting tracers within a patient's body. The increasingly popular small nuclear medicine computer has greatly facilitated the use of mathematical models for interpretation of scintigraphic data, and has made it possible for the clinician and the researcher to extract from the scintigraphic data information not otherwise available. The purpose of this work was to investigate several models used in dynamic scintigraphic studies of the heart. The Xenon washout method of measuring myocardial perfusion is discussed. The use of single-compartment, multi-compartment, and noncompartmental models are critically examined, and the influence of multiexponential components on monoexponential fits for perfusion measurement from Xenon washouts is investigated. A model of cardiac pump function is developed which allows for incompetent valves at the input and output of the ventricular chamber. An iterative method is used in conjunction with the model to estimate forward and regurgitant flows from simulated noisy scintigraphic data and from patient data. Unlike previously available methods, the method presented here was developed to allow noninvasive determination of both mitral and aortic regurgitation. Simulation results were successful, and preliminary studies in a few patients were encouraging. An investigation is presented into the relationship between the count-volume and geometric scintigraphic methods of estimating left ventricular ejection fraction, an important index of the contractile state of the myocardial muscle. A bias due to failure to account for the effects of Poisson noise was found in one popular method for ejection measurement

  5. Assessment of cardiac performance by radionuclide angiocardiography in the patient with myocardial infarction

    International Nuclear Information System (INIS)

    Kimura, Yutaka; Iwasaka, Toshiji; Onoyama, Hideki

    1987-01-01

    The relationship between regional ejection fraction (REF) and left ventricular end-diastolic volume (LVEDV) was examined in 75 patients with myocardial infarction (MI). The infarcted and non-infarcted areas were defined visually from left ventricular REF images obtained by RI angiocardiography. In patients with anterior MI (n = 51), neither left ventricular ejection fraction (LVEF) nor REF in non-infarcted areas (N-REF) was affected by the increase up to 140 ml of LVEDV; however, REF in infarcted areas (I-REF) had already decreased when LVEDV was 100 ml or more. In patients with inferior MI (n = 24), less than 140 ml of LVEDV did not affect any of the dynamic parameters, such as LVEF, 1-REF and N-REF, while 140 ml or more of LVEDV significantly decreased I-REF. When comparing anterior and inferior MIs, I-REF of the anterior MI was readily influenced by ventricular enlargement. In this respect, cardiac reserve of the anterior MI is considered to be limited, as compared with inferior MI. (Namekawa, K.)

  6. Clinical Use of Ultrasensitive Cardiac Troponin I Assay in Intermediate- and High-Risk Surgery Patients

    Directory of Open Access Journals (Sweden)

    Flávia Kessler Borges

    2013-01-01

    Full Text Available Background. Cardiac troponin levels have been reported to add value in the detection of cardiovascular complications in noncardiac surgery. A sensitive cardiac troponin I (cTnI assay could provide more accurate prognostic information. Methods. This study prospectively enrolled 142 patients with at least one Revised Cardiac Risk Index risk factor who underwent noncardiac surgery. cTnI levels were measured postoperatively. Short-term cardiac outcome predictors were evaluated. Results. cTnI elevation was observed in 47 patients, among whom 14 were diagnosed as having myocardial infarction (MI. After 30 days, 16 patients had major adverse cardiac events (MACE. Excluding patients with a final diagnosis of MI, predictors of cTnI elevation included dialysis, history of heart failure, transoperative major bleeding, and elevated levels of pre- and postoperative N-terminal pro-B-type natriuretic peptide (NT-proBNP. Maximal cTnI values showed the highest sensitivity (94%, specificity (75%, and overall accuracy (AUC 0.89; 95% CI 0.80–0.98 for postoperative MACE. Postoperative cTnI peak level (OR 9.4; 95% CI 2.3–39.2 and a preoperative NT-proBNP level ≥917 pg/mL (OR 3.47; 95% CI 1.05–11.6 were independent risk factors for MACE. Conclusions. cTnI was shown to be an independent prognostic factor for cardiac outcomes and should be considered as a component of perioperative risk assessment.

  7. Cardiac autonomic response following high-intensity running work-to-rest interval manipulation.

    Science.gov (United States)

    Cipryan, Lukas; Laursen, Paul B; Plews, Daniel J

    2016-10-01

    The cardiorespiratory, cardiac autonomic (via heart rate variability (HRV)) and plasma volume responses to varying sequences of high-intensity interval training (HIT) of consistent external work were investigated. Twelve moderately trained males underwent three HIT bouts and one control session. The HIT trials consisted of warm-up, followed by 12 min of 15 s, 30 s or 60 s work:relief HIT sequences at an exercise intensity of 100% of the individual velocity at [Formula: see text]O2max (v[Formula: see text]O2max), interspersed by relief intervals at 60% [Formula: see text]O2max (work/relief ratio = 1). HRV was evaluated via the square root of the mean sum of the squared differences between R-R intervals (rMSSD) before, 1 h, 3 h and 24 h after the exercise. Plasma volume was assessed before, immediately after, and 3 h and 24 h after. There were no substantial between-trial differences in acute cardiorespiratory responses. The rMSSD values remained decreased 1 h after the exercise cessation in all exercise groups. The rMSSD subsequently increased between 1 h and 3 h after exercise, with the most pronounced change in the 15/15 group. There were no relationships between HRV and plasma volume. All HIT protocols resulted in similar cardiorespiratory responses with slightly varying post-exercise HRV responses, with the 30/30 protocol eliciting the least disruption to post-exercise HRV. These post-exercise HRV findings suggest that the 30/30 sequence may be the preferable HIT prescription when the between-training period is limited.

  8. Cardiac performance measure compliance in outpatients: the American College of Cardiology and National Cardiovascular Data Registry's PINNACLE (Practice Innovation And Clinical Excellence) program.

    Science.gov (United States)

    Chan, Paul S; Oetgen, William J; Buchanan, Donna; Mitchell, Kristi; Fiocchi, Fran F; Tang, Fengming; Jones, Philip G; Breeding, Tracie; Thrutchley, Duane; Rumsfeld, John S; Spertus, John A

    2010-06-29

    We examined compliance with performance measures for 14,464 patients enrolled from July 2008 through June 2009 into the American College of Cardiology's PINNACLE (Practice Innovation And Clinical Excellence) program to provide initial insights into the quality of outpatient cardiac care. Little is known about the quality of care of outpatients with coronary artery disease (CAD), heart failure, and atrial fibrillation, and whether sex and racial disparities exist in the treatment of outpatients. The PINNACLE program is the first, national, prospective office-based quality improvement program of cardiac patients designed, in part, to capture, report, and improve outpatient performance measure compliance. We examined the proportion of patients whose care was compliant with established American College of Cardiology, American Heart Association, and American Medical Association-Physician Consortium for Performance Improvement (ACC/AHA/PCPI) performance measures for CAD, heart failure, and atrial fibrillation. There were 14,464 unique patients enrolled from 27 U.S. practices, accounting for 18,021 clinical visits. Of these, 8,132 (56.4%) had CAD, 5,012 (34.7%) had heart failure, and 2,786 (19.3%) had nonvalvular atrial fibrillation. Data from the PINNACLE program were feasibly collected for 24 of 25 ACC/AHA/PCPI performance measures. Compliance with performance measures ranged from being very low (e.g., 13.3% of CAD patients screened for diabetes mellitus) to very high (e.g., 96.7% of heart failure patients with blood pressure assessments), with moderate (70% to 90%) compliance observed for most performance measures. For 3 performance measures, there were small differences in compliance rates by race or sex. For more than 14,000 patients enrolled from 27 practices in the outpatient PINNACLE program, we found that compliance with performance measures was variable, even after accounting for exclusion criteria, suggesting an important opportunity to improve the quality of

  9. High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus

    Energy Technology Data Exchange (ETDEWEB)

    Yamamura, Jin; Frisch, Michael; Adam, Gerhard; Wedegaertner, Ulrike [University Hospital Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schnackenburg, Bernhard; Kooijmann, Hendrik [Philips Medical Systems, Hamburg (Germany); Hecher, Kurt [University Hospital Hamburg-Eppendorf, Department of Obstetrics and Fetal Medicine, Hamburg (Germany)

    2009-10-15

    The aim of this study was to perform fetal cardiac magnetic resonance imaging (MRI) with triggering of the fetal heart beat in utero in a sheep model. All experimental protocols were reviewed and the usage of ewes and fetuses was approved by the local animal protection authorities. Images of the hearts of six pregnant ewes were obtained by using a 1.5-T MR system (Philips Medical Systems, Best, Netherlands). The fetuses were chronically instrumented with a carotid catheter to measure the fetal heart frequency for the cardiac triggering. Pulse wave triggered, breath-hold cine-MRI with steady-state free precession (SSFP) was achieved in short axis, two-, four- and three-chamber views. The left ventricular volume and thus the function were measured from the short axis. The fetal heart frequencies ranged between 130 and 160 bpm. The mitral, tricuspid, aortic, and pulmonary valves could be clearly observed. The foramen ovale could be visualized. Myocardial contraction was shown in cine sequences. The average blood volume at the end systole was 3.4{+-}0.2 ml ({+-} SD). The average volume at end diastole was 5.2{+-}0.2 ml; thus the stroke volumes of the left ventricle in the systole were between 1.7 and 1.9 ml with ejection fractions of 38.6% and 39%, respectively. The pulse wave triggered cardiac MRI of the fetal heart allowed evaluation of anatomical structures and functional information. This feasibility study demonstrates the applicability of MRI for future evaluation of fetuses with complex congenital heart defects, once a noninvasive method has been developed to perform fetal cardiac triggering. (orig.)

  10. Intraoperative adverse events can be compensated by technical performance in neonates and infants after cardiac surgery: a prospective study.

    Science.gov (United States)

    Nathan, Meena; Karamichalis, John M; Liu, Hua; del Nido, Pedro; Pigula, Frank; Thiagarajan, Ravi; Bacha, Emile A

    2011-11-01

    Our objective was to define the relationship between surgical technical performance score, intraoperative adverse events, and major postoperative adverse events in complex pediatric cardiac repairs. Infants younger than 6 months were prospectively followed up until discharge from the hospital. Technical performance scores were graded as optimal, adequate, or inadequate based on discharge echocardiograms and need for reintervention after initial surgery. Case complexity was determined by Risk Adjustment in Congenital Heart Surgery (RACHS-1) category, and preoperative illness severity was assessed by Pediatric Risk of Mortality (PRISM) III score. Intraoperative adverse events were prospectively monitored. Outcomes were analyzed using nonparametric methods and a logistic regression model. A total of 166 patients (RACHS 4-6 [49%]), neonates [50%]) were observed. Sixty-one (37%) had at least 1 intraoperative adverse event, and 47 (28.3%) had at least 1 major postoperative adverse event. There was no correlation between intraoperative adverse events and RACHS, preoperative PRISM III, technical performance score, or postoperative adverse events on multivariate analysis. For the entire cohort, better technical performance score resulted in lower postoperative adverse events, lower postoperative PRISM, and lower length of stay and ventilation time (P events, including surgical revisions, provided technical performance score is at least adequate. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  11. Cardiac autonomic functions and the emergence of violence in a highly realistic model of social conflict in humans.

    Directory of Open Access Journals (Sweden)

    Jozsef eHaller

    2014-10-01

    Full Text Available Among the multitude of factors that can transform human social interactions into violent conflicts, biological features received much attention in recent years as correlates of decision making and aggressiveness especially in critical situations. We present here a highly realistic new model of human aggression and violence, where genuine acts of aggression are readily performed and which at the same time allows the parallel recording of biological concomitants. Particularly, we studied police officers trained at the International Training Centre (Budapest, Hungary, who are prepared to perform operations under extreme conditions of stress. We found that aggressive arousal can transform a basically peaceful social encounter into a violent conflict. Autonomic recordings show that this change is accompanied by increased heart rates, which was associated earlier with reduced cognitive complexity of perceptions (attentional myopia and promotes a bias towards hostile attributions and aggression. We also observed reduced heart rate variability in violent subjects, which is believed to signal a poor functioning of prefrontal-subcortical inhibitory circuits and reduces self-control. Importantly, these autonomic particularities were observed already at the beginning of social encounters i.e. before aggressive acts were initiated, suggesting that individual characteristics of the stress-response define the way in which social pressure affects social behavior, particularly the way in which this develops into violence. Taken together, these findings suggest that cardiac autonomic functions are valuable external symptoms of internal motivational states and decision making processes, and raise the possibility that behavior under social pressure can be predicted by the individual characteristics of stress responsiveness.

  12. Implementing a Cardiac Skills Orientation and Simulation Program.

    Science.gov (United States)

    Hemingway, Maureen W; Osgood, Patrice; Mannion, Mildred

    2018-02-01

    Patients with cardiac morbidities admitted for cardiac surgical procedures require perioperative nurses with a high level of complex nursing skills. Orienting new cardiac team members takes commitment and perseverance in light of variable staffing levels, high-acuity patient populations, an active cardiac surgical schedule, and the unpredictability of scheduling patients undergoing cardiac transplantation. At an academic medical center in Boston, these issues presented opportunities to orient new staff members to the scrub person role, but hampered efforts to provide active learning opportunities in a safe environment. As a result, facility personnel created a program to increase new staff members' skills, confidence, and proficiency, while also increasing the number of staff members who were proficient at scrubbing complex cardiac procedures. To address the safe learning requirement, personnel designed a simulation program to provide scrubbing experience, decrease orientees' supervision time, and increase staff members' confidence in performing the scrub person role. © AORN, Inc, 2018.

  13. High performance bio-integrated devices

    Science.gov (United States)

    Kim, Dae-Hyeong; Lee, Jongha; Park, Minjoon

    2014-06-01

    In recent years, personalized electronics for medical applications, particularly, have attracted much attention with the rise of smartphones because the coupling of such devices and smartphones enables the continuous health-monitoring in patients' daily life. Especially, it is expected that the high performance biomedical electronics integrated with the human body can open new opportunities in the ubiquitous healthcare. However, the mechanical and geometrical constraints inherent in all standard forms of high performance rigid wafer-based electronics raise unique integration challenges with biotic entities. Here, we describe materials and design constructs for high performance skin-mountable bio-integrated electronic devices, which incorporate arrays of single crystalline inorganic nanomembranes. The resulting electronic devices include flexible and stretchable electrophysiology electrodes and sensors coupled with active electronic components. These advances in bio-integrated systems create new directions in the personalized health monitoring and/or human-machine interfaces.

  14. Cardiac ablation

    Directory of Open Access Journals (Sweden)

    Kelly Ratheal

    2016-01-01

    Full Text Available Cardiac ablation is a procedure that uses either radiofrequency or cryothermal energy to destroy cells in the heart to terminate and/or prevent arrhythmias. The indications for cardiac catheter ablation include refractory, symptomatic arrhythmias, with more specific guidelines for atrial fibrillation in particular. The ablation procedure itself involves mapping the arrhythmia and destruction of the aberrant pathway in an effort to permanently prevent the arrhythmia. There are many types of arrhythmias, and they require individualized approaches to ablation based on their innately different electrical pathways. Ablation of arrhythmias, such as Wolff-Parkinson-White syndrome, AV nodal reentrant tachycardia, and atrial-fibrillation, is discussed in this review. Ablation has a high success rate overall and minimal complication rates, leading to improved quality of life in many patients.

  15. Respiratory and Cardiac Resuscitation Skills of the High School Athletic Coach.

    Science.gov (United States)

    Furney, Steven

    Athletic coaches (n=149) responded to a survey questionnaire on two cardiac and respiratory emergency procedures: cardiopulmonary resuscitation (CPR) and the Heimlich maneuver. The coaches were asked to indicate how proficient they were at these skills, how important these skills were to their job, the availability and the need for in-service…

  16. Designing a High Performance Parallel Personal Cluster

    OpenAIRE

    Kapanova, K. G.; Sellier, J. M.

    2016-01-01

    Today, many scientific and engineering areas require high performance computing to perform computationally intensive experiments. For example, many advances in transport phenomena, thermodynamics, material properties, computational chemistry and physics are possible only because of the availability of such large scale computing infrastructures. Yet many challenges are still open. The cost of energy consumption, cooling, competition for resources have been some of the reasons why the scientifi...

  17. vSphere high performance cookbook

    CERN Document Server

    Sarkar, Prasenjit

    2013-01-01

    vSphere High Performance Cookbook is written in a practical, helpful style with numerous recipes focusing on answering and providing solutions to common, and not-so common, performance issues and problems.The book is primarily written for technical professionals with system administration skills and some VMware experience who wish to learn about advanced optimization and the configuration features and functions for vSphere 5.1.

  18. High intensity interval and endurance training have opposing effects on markers of heart failure and cardiac remodeling in hypertensive rats.

    Science.gov (United States)

    Holloway, Tanya M; Bloemberg, Darin; da Silva, Mayne L; Simpson, Jeremy A; Quadrilatero, Joe; Spriet, Lawrence L

    2015-01-01

    There has been re-emerging interest and significant work dedicated to investigating the metabolic effects of high intensity interval training (HIIT) in recent years. HIIT is considered to be a time efficient alternative to classic endurance training (ET) that elicits similar metabolic responses in skeletal muscle. However, there is a lack of information on the impact of HIIT on cardiac muscle in disease. Therefore, we determined the efficacy of ET and HIIT to alter cardiac muscle characteristics involved in the development of diastolic dysfunction, such as ventricular hypertrophy, fibrosis and angiogenesis, in a well-established rodent model of hypertension-induced heart failure before the development of overt heart failure. ET decreased left ventricle fibrosis by ~40% (P hypertension. However, HIIT promoted a pathological adaptation in the left ventricle in the presence of hypertension, highlighting the need for further research on the widespread effects of HIIT in the presence of disease.

  19. Sutureless versus Conventional Aortic Valve Replacement: Outcomes in 70 High-Risk Patients Undergoing Concomitant Cardiac Procedures.

    Science.gov (United States)

    Hanedan, Muhammet Onur; Yuruk, Mehmet Ali; Parlar, Ali Ihsan; Ziyrek, Ugur; Arslan, Ali Kemal; Sayar, Ufuk; Mataraci, Ilker

    2018-02-01

    In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P =0.001), postoperative drainage amounts were lower ( P =0.009), hospital stays were shorter ( P =0.004), and less red blood cell transfusion was needed ( P =0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P =0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.

  20. High performance parallel I/O

    CERN Document Server

    Prabhat

    2014-01-01

    Gain Critical Insight into the Parallel I/O EcosystemParallel I/O is an integral component of modern high performance computing (HPC), especially in storing and processing very large datasets to facilitate scientific discovery. Revealing the state of the art in this field, High Performance Parallel I/O draws on insights from leading practitioners, researchers, software architects, developers, and scientists who shed light on the parallel I/O ecosystem.The first part of the book explains how large-scale HPC facilities scope, configure, and operate systems, with an emphasis on choices of I/O har

  1. Performance comparison of independent component analysis algorithms for fetal cardiac signal reconstruction: a study on synthetic fMCG data

    International Nuclear Information System (INIS)

    Mantini, D; II, K E Hild; Alleva, G; Comani, S

    2006-01-01

    Independent component analysis (ICA) algorithms have been successfully used for signal extraction tasks in the field of biomedical signal processing. We studied the performances of six algorithms (FastICA, CubICA, JADE, Infomax, TDSEP and MRMI-SIG) for fetal magnetocardiography (fMCG). Synthetic datasets were used to check the quality of the separated components against the original traces. Real fMCG recordings were simulated with linear combinations of typical fMCG source signals: maternal and fetal cardiac activity, ambient noise, maternal respiration, sensor spikes and thermal noise. Clusters of different dimensions (19, 36 and 55 sensors) were prepared to represent different MCG systems. Two types of signal-to-interference ratios (SIR) were measured. The first involves averaging over all estimated components and the second is based solely on the fetal trace. The computation time to reach a minimum of 20 dB SIR was measured for all six algorithms. No significant dependency on gestational age or cluster dimension was observed. Infomax performed poorly when a sub-Gaussian source was included; TDSEP and MRMI-SIG were sensitive to additive noise, whereas FastICA, CubICA and JADE showed the best performances. Of all six methods considered, FastICA had the best overall performance in terms of both separation quality and computation times

  2. Measurement of physical performance by field tests in programs of cardiac rehabilitation: a systematic review and meta-analysis.

    Science.gov (United States)

    Travensolo, Cristiane; Goessler, Karla; Poton, Roberto; Pinto, Roberta Ramos; Polito, Marcos Doederlein

    2018-04-13

    The literature concerning the effects of cardiac rehabilitation (CR) on field tests results is inconsistent. To perform a systematic review with meta-analysis on field tests results after programs of CR. Studies published in PubMed and Web of Science databases until May 2016 were analyzed. The standard difference in means correct by bias (Hedges' g) was used as effect size (g) to measure que amount of modifications in performance of field tests after CR period. Potential differences between subgroups were analyzed by Q-test based on ANOVA. Fifteen studies published between 1996 e 2016 were included in the review, 932 patients and age ranged 54,4 - 75,3 years old. Fourteen studies used the six-minutes walking test to evaluate the exercise capacity and one study used the Shuttle Walk Test. The random Hedges's g was 0.617 (P<0.001), representing a drop of 20% in the performance of field test after CR. The meta-regression showed significantly association (P=0.01) to aerobic exercise duration, i.e., for each 1-min increase in aerobic exercise duration, there is a 0.02 increase in effect size for performance in the field test. Field tests can detect physical modification after CR, and the large duration of aerobic exercise during CR was associated with a better result. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. A predictive model to identify patients with suspected acute coronary syndromes at high risk of cardiac arrest or in-hospital mortality: An IMMEDIATE Trial sub-study

    Directory of Open Access Journals (Sweden)

    Madhab Ray

    2015-12-01

    Conclusions: The multivariable predictive model developed identified patients with very early ACS at high risk of cardiac arrest or death. Using this model could assist treating those with greatest potential benefit from GIK.

  4. Upconverting nanophosphors as reporters in a highly sensitive heterogeneous immunoassay for cardiac troponin I

    Energy Technology Data Exchange (ETDEWEB)

    Sirkka, Nina, E-mail: nkelon@utu.fi; Lyytikäinen, Annika; Savukoski, Tanja; Soukka, Tero

    2016-06-21

    Photon upconverting nanophosphors (UCNPs) have a unique capability to produce anti-Stokes emission at visible wavelengths via sequential multiphoton absorption upon infrared excitation. Since the anti-Stokes emission can be easily spectrally resolved from the Stokes' shifted autofluorescence, the upconversion luminescence (UCL) is a highly attractive reporter technology for optical biosensors and biomolecular binding assays – potentially enabling unprecedented sensitivity in separation-based solid-phase immunoassays. UCL technology has not previously been applied in sensitive detection of cardiac troponin I (cTnI), which requires highly sensitive detection to enable accurate and timely diagnosis of myocardial infarction. We have developed an UCL-based immunoassay for cTnI using NaYF{sub 4}: Yb{sup 3+}, Er{sup 3+} UCNPs as reporters. Biotinylated anti-cTnI monoclonal antibody (Mab) and Fab fragment immobilized to streptavidin-coated wells were used to capture cTnI. Captured cTnI was detected from dry well surface after a 15 min incubation with poly(acrylic acid) coated UCNPs conjugated to second anti-cTnI Mab. UCL was measured with a dedicated UCL microplate reader. The UCL-based immunoassay allowed sensitive detection of cTnI. The limit of detection was 3.14 ng L{sup −1}. The calibration curve was linear up to cTnI concentration 50,000 ng L{sup −1}. Plasma recoveries of added cTnI were 92–117%. Obtained cTnI concentrations from five normal plasma samples were 4.13–10.7 ng L{sup −1} (median 5.06 ng L{sup −1}). There is yet significant potential for even further improved limit of detection by reducing non-specifically bound fraction of the Mab-conjugated UCNPs. The assay background with zero calibrator was over 40-fold compared to the background obtained from wells where the reporter conjugate had been excluded. - Highlights: • Detection of attomole analyte quantity in microwell using upconversion luminescence. • Upconverting

  5. Strategy Guideline: Partnering for High Performance Homes

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D.

    2013-01-01

    High performance houses require a high degree of coordination and have significant interdependencies between various systems in order to perform properly, meet customer expectations, and minimize risks for the builder. Responsibility for the key performance attributes is shared across the project team and can be well coordinated through advanced partnering strategies. For high performance homes, traditional partnerships need to be matured to the next level and be expanded to all members of the project team including trades, suppliers, manufacturers, HERS raters, designers, architects, and building officials as appropriate. In an environment where the builder is the only source of communication between trades and consultants and where relationships are, in general, adversarial as opposed to cooperative, the chances of any one building system to fail are greater. Furthermore, it is much harder for the builder to identify and capitalize on synergistic opportunities. Partnering can help bridge the cross-functional aspects of the systems approach and achieve performance-based criteria. Critical success factors for partnering include support from top management, mutual trust, effective and open communication, effective coordination around common goals, team building, appropriate use of an outside facilitator, a partnering charter progress toward common goals, an effective problem-solving process, long-term commitment, continuous improvement, and a positive experience for all involved.

  6. Long-term bridge performance high priority bridge performance issues.

    Science.gov (United States)

    2014-10-01

    Bridge performance is a multifaceted issue involving performance of materials and protective systems, : performance of individual components of the bridge, and performance of the structural system as a whole. The : Long-Term Bridge Performance (LTBP)...

  7. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  8. An Introduction to High Performance Fortran

    Directory of Open Access Journals (Sweden)

    John Merlin

    1995-01-01

    Full Text Available High Performance Fortran (HPF is an informal standard for extensions to Fortran 90 to assist its implementation on parallel architectures, particularly for data-parallel computation. Among other things, it includes directives for specifying data distribution across multiple memories, and concurrent execution features. This article provides a tutorial introduction to the main features of HPF.

  9. High performance computing on vector systems

    CERN Document Server

    Roller, Sabine

    2008-01-01

    Presents the developments in high-performance computing and simulation on modern supercomputer architectures. This book covers trends in hardware and software development in general and specifically the vector-based systems and heterogeneous architectures. It presents innovative fields like coupled multi-physics or multi-scale simulations.

  10. High Performance Electronics on Flexible Silicon

    KAUST Repository

    Sevilla, Galo T.

    2016-09-01

    Over the last few years, flexible electronic systems have gained increased attention from researchers around the world because of their potential to create new applications such as flexible displays, flexible energy harvesters, artificial skin, and health monitoring systems that cannot be integrated with conventional wafer based complementary metal oxide semiconductor processes. Most of the current efforts to create flexible high performance devices are based on the use of organic semiconductors. However, inherent material\\'s limitations make them unsuitable for big data processing and high speed communications. The objective of my doctoral dissertation is to develop integration processes that allow the transformation of rigid high performance electronics into flexible ones while maintaining their performance and cost. In this work, two different techniques to transform inorganic complementary metal-oxide-semiconductor electronics into flexible ones have been developed using industry compatible processes. Furthermore, these techniques were used to realize flexible discrete devices and circuits which include metal-oxide-semiconductor field-effect-transistors, the first demonstration of flexible Fin-field-effect-transistors, and metal-oxide-semiconductors-based circuits. Finally, this thesis presents a new technique to package, integrate, and interconnect flexible high performance electronics using low cost additive manufacturing techniques such as 3D printing and inkjet printing. This thesis contains in depth studies on electrical, mechanical, and thermal properties of the fabricated devices.

  11. Debugging a high performance computing program

    Science.gov (United States)

    Gooding, Thomas M.

    2013-08-20

    Methods, apparatus, and computer program products are disclosed for debugging a high performance computing program by gathering lists of addresses of calling instructions for a plurality of threads of execution of the program, assigning the threads to groups in dependence upon the addresses, and displaying the groups to identify defective threads.

  12. Technology Leadership in Malaysia's High Performance School

    Science.gov (United States)

    Yieng, Wong Ai; Daud, Khadijah Binti

    2017-01-01

    Headmaster as leader of the school also plays a role as a technology leader. This applies to the high performance schools (HPS) headmaster as well. The HPS excel in all aspects of education. In this study, researcher is interested in examining the role of the headmaster as a technology leader through interviews with three headmasters of high…

  13. Toward High Performance in Industrial Refrigeration Systems

    DEFF Research Database (Denmark)

    Thybo, C.; Izadi-Zamanabadi, Roozbeh; Niemann, H.

    2002-01-01

    Achieving high performance in complex industrial systems requires information manipulation at different system levels. The paper shows how different models of same subsystems, but using different quality of information/data, are used for fault diagnosis as well as robust control design...

  14. Towards high performance in industrial refrigeration systems

    DEFF Research Database (Denmark)

    Thybo, C.; Izadi-Zamanabadi, R.; Niemann, Hans Henrik

    2002-01-01

    Achieving high performance in complex industrial systems requires information manipulation at different system levels. The paper shows how different models of same subsystems, but using different quality of information/data, are used for fault diagnosis as well as robust control design...

  15. Validated high performance liquid chromatographic (HPLC) method ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-22

    Feb 22, 2010 ... specific and accurate high performance liquid chromatographic method for determination of ZER in micro-volumes ... tional medicine as a cure for swelling, sores, loss of appetite and ... Receptor Activator for Nuclear Factor κ B Ligand .... The effect of ... be suitable for preclinical pharmacokinetic studies. The.

  16. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid ... response, tailing factor and resolution of six replicate injections was < 3 %. ... Cefadroxil monohydrate, Human plasma, Pharmacokinetics Bioequivalence ... Drug-free plasma was obtained from the local .... Influence of probenicid on the renal.

  17. Integrated plasma control for high performance tokamaks

    International Nuclear Information System (INIS)

    Humphreys, D.A.; Deranian, R.D.; Ferron, J.R.; Johnson, R.D.; LaHaye, R.J.; Leuer, J.A.; Penaflor, B.G.; Walker, M.L.; Welander, A.S.; Jayakumar, R.J.; Makowski, M.A.; Khayrutdinov, R.R.

    2005-01-01

    Sustaining high performance in a tokamak requires controlling many equilibrium shape and profile characteristics simultaneously with high accuracy and reliability, while suppressing a variety of MHD instabilities. Integrated plasma control, the process of designing high-performance tokamak controllers based on validated system response models and confirming their performance in detailed simulations, provides a systematic method for achieving and ensuring good control performance. For present-day devices, this approach can greatly reduce the need for machine time traditionally dedicated to control optimization, and can allow determination of high-reliability controllers prior to ever producing the target equilibrium experimentally. A full set of tools needed for this approach has recently been completed and applied to present-day devices including DIII-D, NSTX and MAST. This approach has proven essential in the design of several next-generation devices including KSTAR, EAST, JT-60SC, and ITER. We describe the method, results of design and simulation tool development, and recent research producing novel approaches to equilibrium and MHD control in DIII-D. (author)

  18. Project materials [Commercial High Performance Buildings Project

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-01-01

    The Consortium for High Performance Buildings (ChiPB) is an outgrowth of DOE'S Commercial Whole Buildings Roadmapping initiatives. It is a team-driven public/private partnership that seeks to enable and demonstrate the benefit of buildings that are designed, built and operated to be energy efficient, environmentally sustainable, superior quality, and cost effective.

  19. High performance structural ceramics for nuclear industry

    International Nuclear Information System (INIS)

    Pujari, Vimal K.; Faker, Paul

    2006-01-01

    A family of Saint-Gobain structural ceramic materials and products produced by its High performance Refractory Division is described. Over the last fifty years or so, Saint-Gobain has been a leader in developing non oxide ceramic based novel materials, processes and products for application in Nuclear, Chemical, Automotive, Defense and Mining industries

  20. A new high performance current transducer

    International Nuclear Information System (INIS)

    Tang Lijun; Lu Songlin; Li Deming

    2003-01-01

    A DC-100 kHz current transducer is developed using a new technique on zero-flux detecting principle. It was shown that the new current transducer is of high performance, its magnetic core need not be selected very stringently, and it is easy to manufacture

  1. Strategy Guideline. High Performance Residential Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Holton, J. [IBACOS, Inc., Pittsburgh, PA (United States)

    2012-02-01

    This report has been developed to provide a tool for the understanding and application of high performance lighting in the home. The strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies to greatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner’s expectations for high quality lighting.

  2. Cardiac Hypertrophy and Brain Natriuretic Peptide Levels in an Ovariectomized Rat Model Fed a High-Fat Diet

    Science.gov (United States)

    Goncalves, Gleisy Kelly; de Oliveira, Thiago Henrique Caldeira; de Oliveira Belo, Najara

    2017-01-01

    Background Heart failure in women increases around the time of menopause when high-fat diets may result in obesity. The heart produces brain natriuretic peptide (BNP), also known as B-type natriuretic peptide. This aims of this study were to assess cardiac hypertrophy and BNP levels in ovariectomized rats fed a high-fat diet. Material/Methods Forty-eight female Wistar rats were divided into four groups: sham-operated rats fed a control diet (SC) (n=12); ovariectomized rats fed a control diet (OC) (n=12); sham-operated rats fed a high-fat diet (SF) (n=12); and ovariectomized rats fed a high-fat diet (OF) (n=12). Body weight and blood pressure were measured weekly for 24 weeks. Rats were then euthanized, and plasma samples and heart tissue were studied for gene expression, hydroxyproline levels, and histological examination. Results A high-fat diet and ovariectomy (group OF) increased the weight body and the systolic blood pressure after three months and five months, respectively. Cardiomyocyte hypertrophy was associated with increased expression of ventricular BNP, decreased natriuretic peptide receptor (NPR)-A and increased levels of hydroxyproline and transforming growth factor (TGF)-β. The plasma levels of BNP and estradiol were inversely correlated; expression of estrogen receptor (ER)β and ERα were reduced. Conclusions The findings of this study showed that, in the ovariectomized rats fed a high-fat diet, the BNP-NPR-A receptor complex was involved in cardiac remodeling. BNP may be a marker of cardiac hypertrophy in this animal model. PMID:29249795

  3. Short-term effects of exercise and music on cognitive performance among participants in a cardiac rehabilitation program.

    Science.gov (United States)

    Emery, Charles F; Hsiao, Evana T; Hill, Scott M; Frid, David J

    2003-01-01

    Exercise has been associated with improved cognitive performance among patients with coronary artery disease. Music listening has been associated with enhanced cognitive functioning among healthy adults. This study evaluated the combined influence of exercise and music listening on cognitive performance among patients in cardiac rehabilitation (CR). Using a within-subjects repeated measures design, this study was conducted in an outpatient University-based CR facility. Thirty-three men and women (mean age = 62.6 +/- 10.5 years) participated in this study. Participants completed 1 exercise session accompanied by music and a second exercise session without music. Order of conditions was assigned randomly. Before and after each exercise session, participants completed a brief assessment of depression and anxiety, and a cognitive test of verbal fluency. The music condition was associated with significant improvements in verbal fluency, but the no-music control condition was not associated with cognitive change. The study provides preliminary evidence of the combined benefit of exercise and music listening for cognitive performance among patients in CR.

  4. Biochemical and Ultrastructural Cardiac Changes Induced by High-Fat Diet in Female and Male Prepubertal Rabbits

    Directory of Open Access Journals (Sweden)

    Dina Sibouakaz

    2018-01-01

    Full Text Available Early weight gain induced by high-fat diet has been identified as a predictor for cardiac disease, one of the most serious public health problems. Our goal is to study the influence of a HFD on biochemical, oxidant stress parameters, and the cardiac ultrastructure in both male and female prepubertal models. Experiments were carried on 24 prepubertal New Zealand white rabbits, randomly assigned to male and female control (MC and FC, resp. or HFD (MHFD and FHFD, resp. groups (n=6 for 3 months. Body and heart weights and some biochemical and oxidative stress parameters such as lipids, calcium, CKMB, MDA, uric acid, ascorbic acid, and AOA are evaluated in plasma and the left ventricle. Under HFD effect, plasma parameters, such as lipids (TL, PL, and LDL-C, MDA, and CK-MB, increase more significantly in male than in female groups, when AA decreases. Some cardiac parameters such as TG and UA increase, when AA and AOA decrease; these variations are more significant in FHFD. In both male and female rabbits, HFD caused changes in heart ultrastructure, junctional complexes, mitochondria size and form, and so on. Early HFD feeding induced overweight, oxidative stress, and metabolic alterations in plasma and the heart of prepubertal rabbits, whereas lipotoxicity has especially a negative impact on male plasma but affects more the female heart ultrastructure.

  5. Architecting Web Sites for High Performance

    Directory of Open Access Journals (Sweden)

    Arun Iyengar

    2002-01-01

    Full Text Available Web site applications are some of the most challenging high-performance applications currently being developed and deployed. The challenges emerge from the specific combination of high variability in workload characteristics and of high performance demands regarding the service level, scalability, availability, and costs. In recent years, a large body of research has addressed the Web site application domain, and a host of innovative software and hardware solutions have been proposed and deployed. This paper is an overview of recent solutions concerning the architectures and the software infrastructures used in building Web site applications. The presentation emphasizes three of the main functions in a complex Web site: the processing of client requests, the control of service levels, and the interaction with remote network caches.

  6. High performance anode for advanced Li batteries

    Energy Technology Data Exchange (ETDEWEB)

    Lake, Carla [Applied Sciences, Inc., Cedarville, OH (United States)

    2015-11-02

    The overall objective of this Phase I SBIR effort was to advance the manufacturing technology for ASI’s Si-CNF high-performance anode by creating a framework for large volume production and utilization of low-cost Si-coated carbon nanofibers (Si-CNF) for the battery industry. This project explores the use of nano-structured silicon which is deposited on a nano-scale carbon filament to achieve the benefits of high cycle life and high charge capacity without the consequent fading of, or failure in the capacity resulting from stress-induced fracturing of the Si particles and de-coupling from the electrode. ASI’s patented coating process distinguishes itself from others, in that it is highly reproducible, readily scalable and results in a Si-CNF composite structure containing 25-30% silicon, with a compositionally graded interface at the Si-CNF interface that significantly improve cycling stability and enhances adhesion of silicon to the carbon fiber support. In Phase I, the team demonstrated the production of the Si-CNF anode material can successfully be transitioned from a static bench-scale reactor into a fluidized bed reactor. In addition, ASI made significant progress in the development of low cost, quick testing methods which can be performed on silicon coated CNFs as a means of quality control. To date, weight change, density, and cycling performance were the key metrics used to validate the high performance anode material. Under this effort, ASI made strides to establish a quality control protocol for the large volume production of Si-CNFs and has identified several key technical thrusts for future work. Using the results of this Phase I effort as a foundation, ASI has defined a path forward to commercialize and deliver high volume and low-cost production of SI-CNF material for anodes in Li-ion batteries.

  7. Effect of a web-based audit and feedback intervention with outreach visits on the clinical performance of multidisciplinary teams: a cluster-randomized trial in cardiac rehabilitation

    NARCIS (Netherlands)

    Gude, Wouter T.; van Engen-Verheul, Mariëtte M.; van der Veer, Sabine N.; Kemps, Hareld M. C.; Jaspers, Monique W. M.; de Keizer, Nicolette F.; Peek, Niels

    2016-01-01

    The objective of this study was to assess the effect of a web-based audit and feedback (A&F) intervention with outreach visits to support decision-making by multidisciplinary teams. We performed a multicentre cluster-randomized trial within the field of comprehensive cardiac rehabilitation (CR) in

  8. NINJA: Java for High Performance Numerical Computing

    Directory of Open Access Journals (Sweden)

    José E. Moreira

    2002-01-01

    Full Text Available When Java was first introduced, there was a perception that its many benefits came at a significant performance cost. In the particularly performance-sensitive field of numerical computing, initial measurements indicated a hundred-fold performance disadvantage between Java and more established languages such as Fortran and C. Although much progress has been made, and Java now can be competitive with C/C++ in many important situations, significant performance challenges remain. Existing Java virtual machines are not yet capable of performing the advanced loop transformations and automatic parallelization that are now common in state-of-the-art Fortran compilers. Java also has difficulties in implementing complex arithmetic efficiently. These performance deficiencies can be attacked with a combination of class libraries (packages, in Java that implement truly multidimensional arrays and complex numbers, and new compiler techniques that exploit the properties of these class libraries to enable other, more conventional, optimizations. Two compiler techniques, versioning and semantic expansion, can be leveraged to allow fully automatic optimization and parallelization of Java code. Our measurements with the NINJA prototype Java environment show that Java can be competitive in performance with highly optimized and tuned Fortran code.

  9. A case of spuriously high CK-MB: Contemplate beyond cardiac

    Directory of Open Access Journals (Sweden)

    Rishard Abdul

    2017-10-01

    Full Text Available Creatine kinase-MB (CK-MB is a widely tested enzyme in cardiac disease and thus has important clinical implications. We relate the scenario of a young patient presenting with chest pain whose CK-MB levels remained inordinately elevated despite a normal total CK level, resolution of symptoms and exclusion of coronary artery disease. Further analysis by electrophoresis revealed the presence of a rare molecular variant of creatine kinase: macro-CK type 1. While this may be a benign finding, there are sparse data demonstrating an association with non-cardiac pathologies such as malignancy, endocrinopathies, connective tissue and autoimmune diseases. Thus, after further exclusion of these associated conditions, the patient was reassured on the likely benign nature of macro-CK in this case.

  10. Transfusion algorithms and how they apply to blood conservation: the high-risk cardiac surgical patient.

    Science.gov (United States)

    Steiner, Marie E; Despotis, George John

    2007-02-01

    Considerable blood product support is administered to the cardiac surgery population. Due to the multifactorial etiology of bleeding in the cardiac bypass patient, blood products frequently and empirically are infused to correct bleeding, with varying success. Several studies have demonstrated the benefit of algorithm-guided transfusion in reducing blood loss, transfusion exposure, or rate of surgical re-exploration for bleeding. Some transfusion algorithms also incorporate laboratory-based decision points in their guidelines. Despite published success with standardized transfusion practices, generalized change in blood use has not been realized, and it is evident that current laboratory-guided hemostasis measures are inadequate to define and address the bleeding etiology in these patients.

  11. Simulation training improves team dynamics and performance in a low-resource cardiac intensive care unit

    Directory of Open Access Journals (Sweden)

    Sivaram Subaya Emani

    2018-01-01

    Conclusions: This study demonstrates the feasibility and effectiveness of simulationbased training in improving team dynamics and performance in lowresource pediatric CICU environments, indicating its potential role in eliminating communication barriers in these settings.

  12. Development of high performance cladding materials

    International Nuclear Information System (INIS)

    Park, Jeong Yong; Jeong, Y. H.; Park, S. Y.

    2010-04-01

    The irradiation test for HANA claddings conducted and a series of evaluation for next-HANA claddings as well as their in-pile and out-of pile performances tests were also carried out at Halden research reactor. The 6th irradiation test have been completed successfully in Halden research reactor. As a result, HANA claddings showed high performance, such as corrosion resistance increased by 40% compared to Zircaloy-4. The high performance of HANA claddings in Halden test has enabled lead test rod program as the first step of the commercialization of HANA claddings. DB has been established for thermal and LOCA-related properties. It was confirmed from the thermal shock test that the integrity of HANA claddings was maintained in more expanded region than the criteria regulated by NRC. The manufacturing process of strips was established in order to apply HANA alloys, which were originally developed for the claddings, to the spacer grids. 250 kinds of model alloys for the next-generation claddings were designed and manufactured over 4 times and used to select the preliminary candidate alloys for the next-generation claddings. The selected candidate alloys showed 50% better corrosion resistance and 20% improved high temperature oxidation resistance compared to the foreign advanced claddings. We established the manufacturing condition controlling the performance of the dual-cooled claddings by changing the reduction rate in the cold working steps

  13. A Linux Workstation for High Performance Graphics

    Science.gov (United States)

    Geist, Robert; Westall, James

    2000-01-01

    The primary goal of this effort was to provide a low-cost method of obtaining high-performance 3-D graphics using an industry standard library (OpenGL) on PC class computers. Previously, users interested in doing substantial visualization or graphical manipulation were constrained to using specialized, custom hardware most often found in computers from Silicon Graphics (SGI). We provided an alternative to expensive SGI hardware by taking advantage of third-party, 3-D graphics accelerators that have now become available at very affordable prices. To make use of this hardware our goal was to provide a free, redistributable, and fully-compatible OpenGL work-alike library so that existing bodies of code could simply be recompiled. for PC class machines running a free version of Unix. This should allow substantial cost savings while greatly expanding the population of people with access to a serious graphics development and viewing environment. This should offer a means for NASA to provide a spectrum of graphics performance to its scientists, supplying high-end specialized SGI hardware for high-performance visualization while fulfilling the requirements of medium and lower performance applications with generic, off-the-shelf components and still maintaining compatibility between the two.

  14. The path toward HEP High Performance Computing

    CERN Document Server

    Apostolakis, John; Carminati, Federico; Gheata, Andrei; Wenzel, Sandro

    2014-01-01

    High Energy Physics code has been known for making poor use of high performance computing architectures. Efforts in optimising HEP code on vector and RISC architectures have yield limited results and recent studies have shown that, on modern architectures, it achieves a performance between 10% and 50% of the peak one. Although several successful attempts have been made to port selected codes on GPUs, no major HEP code suite has a 'High Performance' implementation. With LHC undergoing a major upgrade and a number of challenging experiments on the drawing board, HEP cannot any longer neglect the less-than-optimal performance of its code and it has to try making the best usage of the hardware. This activity is one of the foci of the SFT group at CERN, which hosts, among others, the Root and Geant4 project. The activity of the experiments is shared and coordinated via a Concurrency Forum, where the experience in optimising HEP code is presented and discussed. Another activity is the Geant-V project, centred on th...

  15. High Performance Commercial Fenestration Framing Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mike Manteghi; Sneh Kumar; Joshua Early; Bhaskar Adusumalli

    2010-01-31

    A major objective of the U.S. Department of Energy is to have a zero energy commercial building by the year 2025. Windows have a major influence on the energy performance of the building envelope as they control over 55% of building energy load, and represent one important area where technologies can be developed to save energy. Aluminum framing systems are used in over 80% of commercial fenestration products (i.e. windows, curtain walls, store fronts, etc.). Aluminum framing systems are often required in commercial buildings because of their inherent good structural properties and long service life, which is required from commercial and architectural frames. At the same time, they are lightweight and durable, requiring very little maintenance, and offer design flexibility. An additional benefit of aluminum framing systems is their relatively low cost and easy manufacturability. Aluminum, being an easily recyclable material, also offers sustainable features. However, from energy efficiency point of view, aluminum frames have lower thermal performance due to the very high thermal conductivity of aluminum. Fenestration systems constructed of aluminum alloys therefore have lower performance in terms of being effective barrier to energy transfer (heat loss or gain). Despite the lower energy performance, aluminum is the choice material for commercial framing systems and dominates the commercial/architectural fenestration market because of the reasons mentioned above. In addition, there is no other cost effective and energy efficient replacement material available to take place of aluminum in the commercial/architectural market. Hence it is imperative to improve the performance of aluminum framing system to improve the energy performance of commercial fenestration system and in turn reduce the energy consumption of commercial building and achieve zero energy building by 2025. The objective of this project was to develop high performance, energy efficient commercial

  16. Fracture toughness of ultra high performance concrete by flexural performance

    Directory of Open Access Journals (Sweden)

    Manolova Emanuela

    2016-01-01

    Full Text Available This paper describes the fracture toughness of the innovative structural material - Ultra High Performance Concrete (UHPC, evaluated by flexural performance. For determination the material behaviour by static loading are used adapted standard test methods for flexural performance of fiber-reinforced concrete (ASTM C 1609 and ASTM C 1018. Fracture toughness is estimated by various deformation parameters derived from the load-deflection curve, obtained by testing simple supported beam under third-point loading, using servo-controlled testing system. This method is used to be estimated the contribution of the embedded fiber-reinforcement into improvement of the fractural behaviour of UHPC by changing the crack-resistant capacity, fracture toughness and energy absorption capacity with various mechanisms. The position of the first crack has been formulated based on P-δ (load- deflection response and P-ε (load - longitudinal deformation in the tensile zone response, which are used for calculation of the two toughness indices I5 and I10. The combination of steel fibres with different dimensions leads to a composite, having at the same time increased crack resistance, first crack formation, ductility and post-peak residual strength.

  17. Korean guidelines for the appropriate use of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul(Korea, Republic of); Yong, Hwan Seok [Dept. of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul(Korea, Republic of); Kim, Sung Mok [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Jung A [Dept. of Radiology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang (Korea, Republic of); Hong, Yoo Jin [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-04-15

    The development of cardiac CT has provided a non-invasive alternative to echocardiography, exercise electrocardiogram, and invasive angiography and cardiac CT continues to develop at an exponential speed even now. The appropriate use of cardiac CT may lead to improvements in the medical performances of physicians and can reduce medical costs which eventually contribute to better public health. However, until now, there has been no guideline regarding the appropriate use of cardiac CT in Korea. We intend to provide guidelines for the appropriate use of cardiac CT in heart diseases based on scientific data. The purpose of this guideline is to assist clinicians and other health professionals in the use of cardiac CT for diagnosis and treatment of heart diseases, especially in patients at high risk or suspected of heart disease.

  18. Effects of overfeeding and high-fat diet on cardiosomatic parameters and cardiac structures in young and adult zebrafish.

    Science.gov (United States)

    Vargas, Rafael; Vásquez, Isabel Cristina

    2017-12-01

    Obesity is a complex global health problem because it is a risk factor for multiple chronic pathologies such as cardiovascular, endocrine, metabolic, and neoplastic diseases. It is considered a multicausal disease, and one of the determining factors is nutritional imbalances, which include high-fat diets. In this paper, we use the zebrafish model to assess the impact of overfeeding and a high-fat diet in somatic and cardiac parameters in young and adult zebrafish. The results show that fish receiving a high-fat diet showed greater weight gain compared to fish receiving a standard fat diet. Additionally, changes in the heart, including increases in size, a change in the triangular shape of the ventricle to a globular shape, and an increase in the thickness of the trabeculae of the spongy myocardium were observed. These changes could be indicators of cardiovascular overload. The results show that there is a direct relationship between the intake of a high-fat diet and obesity, which in turn can induce cardiac changes, supporting the hypothesis of the relationship between high-fat diets and cardiovascular risk factors. Given the genetic similarity between zebrafish and humans, these results could be extrapolated to human beings, and the findings similarly highlight the importance of incorporating a balanced diet from the early life stages to reduce the risk of cardiovascular disease.

  19. HIGH PERFORMANCE CERIA BASED OXYGEN MEMBRANE

    DEFF Research Database (Denmark)

    2014-01-01

    The invention describes a new class of highly stable mixed conducting materials based on acceptor doped cerium oxide (CeO2-8 ) in which the limiting electronic conductivity is significantly enhanced by co-doping with a second element or co- dopant, such as Nb, W and Zn, so that cerium and the co......-dopant have an ionic size ratio between 0.5 and 1. These materials can thereby improve the performance and extend the range of operating conditions of oxygen permeation membranes (OPM) for different high temperature membrane reactor applications. The invention also relates to the manufacturing of supported...

  20. Playa: High-Performance Programmable Linear Algebra

    Directory of Open Access Journals (Sweden)

    Victoria E. Howle

    2012-01-01

    Full Text Available This paper introduces Playa, a high-level user interface layer for composing algorithms for complex multiphysics problems out of objects from other Trilinos packages. Among other features, Playa provides very high-performance overloaded operators implemented through an expression template mechanism. In this paper, we give an overview of the central Playa objects from a user's perspective, show application to a sequence of increasingly complex solver algorithms, provide timing results for Playa's overloaded operators and other functions, and briefly survey some of the implementation issues involved.

  1. Optimizing the design of very high power, high performance converters

    International Nuclear Information System (INIS)

    Edwards, R.J.; Tiagha, E.A.; Ganetis, G.; Nawrocky, R.J.

    1980-01-01

    This paper describes how various technologies are used to achieve the desired performance in a high current magnet power converter system. It is hoped that the discussions of the design approaches taken will be applicable to other power supply systems where stringent requirements in stability, accuracy and reliability must be met

  2. High-NaCl Diet Aggravates Cardiac Injury in Rats with Adenine-Induced Chronic Renal Failure and Increases Serum Troponin T Levels

    DEFF Research Database (Denmark)

    Kashioulis, Pavlos; Hammarsten, Ola; Marcussen, Niels

    2016-01-01

    AIMS: To examine the effects of 2 weeks of high-NaCl diet on left ventricular (LV) morphology and serum levels of cardiac troponin T (cTnT) in rats with adenine-induced chronic renal failure (ACRF). METHODS: Male Sprague-Dawley rats either received chow containing adenine or were pair......-fed an identical diet without adenine [controls (C)]. Approximately 10 weeks after the beginning of the study, the rats were randomized to either remain on a normal NaCl diet (NNa; 0.6%) or to be switched to high-NaCl chow (HNa; 4%) for 2 weeks, after which acute experiments were performed. RESULTS: Rats with ACRF...... showed statistically significant increases (p rats (p

  3. Robust High Performance Aquaporin based Biomimetic Membranes

    DEFF Research Database (Denmark)

    Helix Nielsen, Claus; Zhao, Yichun; Qiu, C.

    2013-01-01

    on top of a support membrane. Control membranes, either without aquaporins or with the inactive AqpZ R189A mutant aquaporin served as controls. The separation performance of the membranes was evaluated by cross-flow forward osmosis (FO) and reverse osmosis (RO) tests. In RO the ABM achieved a water......Aquaporins are water channel proteins with high water permeability and solute rejection, which makes them promising for preparing high-performance biomimetic membranes. Despite the growing interest in aquaporin-based biomimetic membranes (ABMs), it is challenging to produce robust and defect...... permeability of ~ 4 L/(m2 h bar) with a NaCl rejection > 97% at an applied hydraulic pressure of 5 bar. The water permeability was ~40% higher compared to a commercial brackish water RO membrane (BW30) and an order of magnitude higher compared to a seawater RO membrane (SW30HR). In FO, the ABMs had > 90...

  4. Evaluation of high-performance computing software

    Energy Technology Data Exchange (ETDEWEB)

    Browne, S.; Dongarra, J. [Univ. of Tennessee, Knoxville, TN (United States); Rowan, T. [Oak Ridge National Lab., TN (United States)

    1996-12-31

    The absence of unbiased and up to date comparative evaluations of high-performance computing software complicates a user`s search for the appropriate software package. The National HPCC Software Exchange (NHSE) is attacking this problem using an approach that includes independent evaluations of software, incorporation of author and user feedback into the evaluations, and Web access to the evaluations. We are applying this approach to the Parallel Tools Library (PTLIB), a new software repository for parallel systems software and tools, and HPC-Netlib, a high performance branch of the Netlib mathematical software repository. Updating the evaluations with feed-back and making it available via the Web helps ensure accuracy and timeliness, and using independent reviewers produces unbiased comparative evaluations difficult to find elsewhere.

  5. High performance cloud auditing and applications

    CERN Document Server

    Choi, Baek-Young; Song, Sejun

    2014-01-01

    This book mainly focuses on cloud security and high performance computing for cloud auditing. The book discusses emerging challenges and techniques developed for high performance semantic cloud auditing, and presents the state of the art in cloud auditing, computing and security techniques with focus on technical aspects and feasibility of auditing issues in federated cloud computing environments.   In summer 2011, the United States Air Force Research Laboratory (AFRL) CyberBAT Cloud Security and Auditing Team initiated the exploration of the cloud security challenges and future cloud auditing research directions that are covered in this book. This work was supported by the United States government funds from the Air Force Office of Scientific Research (AFOSR), the AFOSR Summer Faculty Fellowship Program (SFFP), the Air Force Research Laboratory (AFRL) Visiting Faculty Research Program (VFRP), the National Science Foundation (NSF) and the National Institute of Health (NIH). All chapters were partially suppor...

  6. Monitoring SLAC High Performance UNIX Computing Systems

    International Nuclear Information System (INIS)

    Lettsome, Annette K.

    2005-01-01

    Knowledge of the effectiveness and efficiency of computers is important when working with high performance systems. The monitoring of such systems is advantageous in order to foresee possible misfortunes or system failures. Ganglia is a software system designed for high performance computing systems to retrieve specific monitoring information. An alternative storage facility for Ganglia's collected data is needed since its default storage system, the round-robin database (RRD), struggles with data integrity. The creation of a script-driven MySQL database solves this dilemma. This paper describes the process took in the creation and implementation of the MySQL database for use by Ganglia. Comparisons between data storage by both databases are made using gnuplot and Ganglia's real-time graphical user interface

  7. High performance parallel computers for science

    International Nuclear Information System (INIS)

    Nash, T.; Areti, H.; Atac, R.; Biel, J.; Cook, A.; Deppe, J.; Edel, M.; Fischler, M.; Gaines, I.; Hance, R.

    1989-01-01

    This paper reports that Fermilab's Advanced Computer Program (ACP) has been developing cost effective, yet practical, parallel computers for high energy physics since 1984. The ACP's latest developments are proceeding in two directions. A Second Generation ACP Multiprocessor System for experiments will include $3500 RISC processors each with performance over 15 VAX MIPS. To support such high performance, the new system allows parallel I/O, parallel interprocess communication, and parallel host processes. The ACP Multi-Array Processor, has been developed for theoretical physics. Each $4000 node is a FORTRAN or C programmable pipelined 20 Mflops (peak), 10 MByte single board computer. These are plugged into a 16 port crossbar switch crate which handles both inter and intra crate communication. The crates are connected in a hypercube. Site oriented applications like lattice gauge theory are supported by system software called CANOPY, which makes the hardware virtually transparent to users. A 256 node, 5 GFlop, system is under construction

  8. Effect of a single intraoperative high-dose ATG-Fresenius on delayed graft function in donation after cardiac-death donor renal allograft recipients: a randomized study.

    Science.gov (United States)

    van den Hoogen, Martijn W F; Kho, Marcia M L; Abrahams, Alferso C; van Zuilen, Arjan D; Sanders, Jan-Stephan; van Dijk, Marja; Hilbrands, Luuk B; Weimar, Willem; Hoitsma, Andries J

    2013-04-01

    Reducing the incidence of delayed graft function after transplant with donation after cardiac death donor renal allografts would facilitate managing recipients during their first weeks after a transplant. To reduce this incidence, in most studies, induction therapy with depleting anti-T-lymphocyte antibodies is coupled with a reduction of the dosage of the calcineurin inhibitor. The separate effect of anti-T-cell therapy on the incidence and duration of delayed graft function is therefore difficult to assess. We performed a randomized study to evaluate the effect of a single intraoperative high-dose of anti-T-lymphocyte immunoglobulin (ATG)-Fresenius (9 mg/kg body weight) on the incidence of delayed graft function. Eligible adult recipients of a first donation after cardiac death donor renal allograft were randomly assigned to ATG-Fresenius or no induction therapy. Maintenance immunosuppression consisted of tacrolimus, in an unadjusted dose, mycophenolate mofetil, and steroids. The study was prematurely terminated because of a lower-than-anticipated inclusion rate. Baseline characteristics were comparable in the ATG-Fresenius group (n=28) and the control group (n=24). Twenty-two patients in the ATG-Fresenius group (79%) had delayed graft function, compared with 13 in the control group (54%; P = .06). Allograft and patient survival were comparable in both groups. Serious adverse events occurred more frequently in the ATG-Fresenius group than they did in the control group (57% vs 29%; P Fresenius in donation after cardiac death donor renal allograft recipients, followed by triple immunosuppression with an unadjusted tacrolimus dose, seems ineffective to reduce the incidence of delayed graft function. Moreover, this was associated with a higher rate of serious adverse events (EudraCT-number, 2007-000210-36.).

  9. Toward a theory of high performance.

    Science.gov (United States)

    Kirby, Julia

    2005-01-01

    What does it mean to be a high-performance company? The process of measuring relative performance across industries and eras, declaring top performers, and finding the common drivers of their success is such a difficult one that it might seem a fool's errand to attempt. In fact, no one did for the first thousand or so years of business history. The question didn't even occur to many scholars until Tom Peters and Bob Waterman released In Search of Excellence in 1982. Twenty-three years later, we've witnessed several more attempts--and, just maybe, we're getting closer to answers. In this reported piece, HBR senior editor Julia Kirby explores why it's so difficult to study high performance and how various research efforts--including those from John Kotter and Jim Heskett; Jim Collins and Jerry Porras; Bill Joyce, Nitin Nohria, and Bruce Roberson; and several others outlined in a summary chart-have attacked the problem. The challenge starts with deciding which companies to study closely. Are the stars the ones with the highest market caps, the ones with the greatest sales growth, or simply the ones that remain standing at the end of the game? (And when's the end of the game?) Each major study differs in how it defines success, which companies it therefore declares to be worthy of emulation, and the patterns of activity and attitude it finds in common among them. Yet, Kirby concludes, as each study's method incrementally solves problems others have faced, we are progressing toward a consensus theory of high performance.

  10. Impact of quantitative feedback and benchmark selection on radiation use by cardiologists performing cardiac angiography

    International Nuclear Information System (INIS)

    Smith, I. R.; Cameron, J.; Brighouse, R. D.; Ryan, C. M.; Foster, K. A.; Rivers, J. T.

    2013-01-01

    Audit of and feedback on both group and individual data provided immediately after the point of care and compared with realistic benchmarks of excellence have been demonstrated to drive change. This study sought to evaluate the impact of immediate benchmarked quantitative case-based performance feedback on the clinical practice of cardiologists practicing at a private hospital in Brisbane, Australia. The participating cardiologists were assigned to one of two groups: Group 1 received patient and procedural details for review and Group 2 received Group 1 data plus detailed radiation data relating to the procedures and comparative benchmarks. In Group 2, Linear-by-Linear Association analysis suggests a link between change in radiation use and initial radiation dose category (p50.014) with only those initially 'challenged' by the benchmarks showing improvement. Those not 'challenged' by the benchmarks deteriorated in performance compared with those starting well below the benchmarks showing greatest increase in radiation use. Conversely, those blinded to their radiation use (Group 1) showed general improvement in radiation use throughout the study compared with those performing initially close to the benchmarks showing greatest improvement. This study shows that use of non-challenging benchmarks in case-based radiation risk feedback does not promote a reduction in radiation use; indeed, it may contribute to increased doses. Paradoxically, cardiologists who are aware of performance monitoring but blinded to individual case data appear to maintain, if not reduce, their radiation use. (authors)

  11. High-performance phase-field modeling

    KAUST Repository

    Vignal, Philippe; Sarmiento, Adel; Cortes, Adriano Mauricio; Dalcin, L.; Collier, N.; Calo, Victor M.

    2015-01-01

    and phase-field crystal equation will be presented, which corroborate the theoretical findings, and illustrate the robustness of the method. Results related to more challenging examples, namely the Navier-Stokes Cahn-Hilliard and a diusion-reaction Cahn-Hilliard system, will also be presented. The implementation was done in PetIGA and PetIGA-MF, high-performance Isogeometric Analysis frameworks [1, 3], designed to handle non-linear, time-dependent problems.

  12. AHPCRC - Army High Performance Computing Research Center

    Science.gov (United States)

    2010-01-01

    computing. Of particular interest is the ability of a distrib- uted jamming network (DJN) to jam signals in all or part of a sensor or communications net...and reasoning, assistive technologies. FRIEDRICH (FRITZ) PRINZ Finmeccanica Professor of Engineering, Robert Bosch Chair, Department of Engineering...High Performance Computing Research Center www.ahpcrc.org BARBARA BRYAN AHPCRC Research and Outreach Manager, HPTi (650) 604-3732 bbryan@hpti.com Ms

  13. Performance concerns for high duty fuel cycle

    International Nuclear Information System (INIS)

    Esposito, V.J.; Gutierrez, J.E.

    1999-01-01

    One of the goals of the nuclear industry is to achieve economic performance such that nuclear power plants are competitive in a de-regulated market. The manner in which nuclear fuel is designed and operated lies at the heart of economic viability. In this sense reliability, operating flexibility and low costs are the three major requirements of the NPP today. The translation of these three requirements to the design is part of our work. The challenge today is to produce a fuel design which will operate with long operating cycles, high discharge burnup, power up-rating and while still maintaining all design and safety margins. European Fuel Group (EFG) understands that to achieve the required performance high duty/energy fuel designs are needed. The concerns for high duty design includes, among other items, core design methods, advanced Safety Analysis methodologies, performance models, advanced material and operational strategies. The operational aspects require the trade-off and evaluation of various parameters including coolant chemistry control, material corrosion, boiling duty, boron level impacts, etc. In this environment MAEF is the design that EFG is now offering based on ZIRLO alloy and a robust skeleton. This new design is able to achieve 70 GWd/tU and Lead Test Programs are being executed to demonstrate this capability. A number of performance issues which have been a concern with current designs have been resolved such as cladding corrosion and incomplete RCCA insertion (IRI). As the core duty becomes more aggressive other new issues need to be addressed such as Axial Offset Anomaly. These new issues are being addressed by combination of the new design in concert with advanced methodologies to meet the demanding needs of NPP. The ability and strategy to meet high duty core requirements, flexibility of operation and maintain acceptable balance of all technical issues is the discussion in this paper. (authors)

  14. DURIP: High Performance Computing in Biomathematics Applications

    Science.gov (United States)

    2017-05-10

    Mathematics and Statistics (AMS) at the University of California, Santa Cruz (UCSC) to conduct research and research-related education in areas of...Computing in Biomathematics Applications Report Title The goal of this award was to enhance the capabilities of the Department of Applied Mathematics and...DURIP: High Performance Computing in Biomathematics Applications The goal of this award was to enhance the capabilities of the Department of Applied

  15. High Performance Computing Operations Review Report

    Energy Technology Data Exchange (ETDEWEB)

    Cupps, Kimberly C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-12-19

    The High Performance Computing Operations Review (HPCOR) meeting—requested by the ASC and ASCR program headquarters at DOE—was held November 5 and 6, 2013, at the Marriott Hotel in San Francisco, CA. The purpose of the review was to discuss the processes and practices for HPC integration and its related software and facilities. Experiences and lessons learned from the most recent systems deployed were covered in order to benefit the deployment of new systems.

  16. Planning for high performance project teams

    International Nuclear Information System (INIS)

    Reed, W.; Keeney, J.; Westney, R.

    1997-01-01

    Both industry-wide research and corporate benchmarking studies confirm the significant savings in cost and time that result from early planning of a project. Amoco's Team Planning Workshop combines long-term strategic project planning and short-term tactical planning with team building to provide the basis for high performing project teams, better project planning, and effective implementation of the Amoco Common Process for managing projects

  17. Computational Biology and High Performance Computing 2000

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Horst D.; Zorn, Manfred D.; Spengler, Sylvia J.; Shoichet, Brian K.; Stewart, Craig; Dubchak, Inna L.; Arkin, Adam P.

    2000-10-19

    The pace of extraordinary advances in molecular biology has accelerated in the past decade due in large part to discoveries coming from genome projects on human and model organisms. The advances in the genome project so far, happening well ahead of schedule and under budget, have exceeded any dreams by its protagonists, let alone formal expectations. Biologists expect the next phase of the genome project to be even more startling in terms of dramatic breakthroughs in our understanding of human biology, the biology of health and of disease. Only today can biologists begin to envision the necessary experimental, computational and theoretical steps necessary to exploit genome sequence information for its medical impact, its contribution to biotechnology and economic competitiveness, and its ultimate contribution to environmental quality. High performance computing has become one of the critical enabling technologies, which will help to translate this vision of future advances in biology into reality. Biologists are increasingly becoming aware of the potential of high performance computing. The goal of this tutorial is to introduce the exciting new developments in computational biology and genomics to the high performance computing community.

  18. The role of adrenaline as a modulator of cardiac performance in two Antarctic fishes

    DEFF Research Database (Denmark)

    Skov, Peter Vilhelm; Bushnell, Peter G.; Tirsgaard, Bjørn

    2009-01-01

    Abstract: The present work was performed to test the hypothesis that Antarctic teleosts rely mostly on cholinergic inhibition for autonomic modulation of the heart. The effects of adrenaline on the inotropic properties on paced, isometrically contracting muscle strips were examined in two distinct...... to which ventricular tissues responded to adrenaline varied between species, adrenergic stimulation significantly increases myocyte contraction force in this group of fishes. Contraction and relaxation times were not significantly affected by adrenaline concentration while absolute rates of contraction...

  19. High performance separation of lanthanides and actinides

    International Nuclear Information System (INIS)

    Sivaraman, N.; Vasudeva Rao, P.R.

    2011-01-01

    The major advantage of High Performance Liquid Chromatography (HPLC) is its ability to provide rapid and high performance separations. It is evident from Van Deemter curve for particle size versus resolution that packing materials with particle sizes less than 2 μm provide better resolution for high speed separations and resolving complex mixtures compared to 5 μm based supports. In the recent past, chromatographic support material using monolith has been studied extensively at our laboratory. Monolith column consists of single piece of porous, rigid material containing mesopores and micropores, which provide fast analyte mass transfer. Monolith support provides significantly higher separation efficiency than particle-packed columns. A clear advantage of monolith is that it could be operated at higher flow rates but with lower back pressure. Higher operating flow rate results in higher column permeability, which drastically reduces analysis time and provides high separation efficiency. The above developed fast separation methods were applied to assay the lanthanides and actinides from the dissolver solutions of nuclear reactor fuels

  20. High Performance OLED Panel and Luminaire

    Energy Technology Data Exchange (ETDEWEB)

    Spindler, Jeffrey [OLEDWorks LLC, Rochester, NY (United States)

    2017-02-20

    In this project, OLEDWorks developed and demonstrated the technology required to produce OLED lighting panels with high energy efficiency and excellent light quality. OLED panels developed in this program produce high quality warm white light with CRI greater than 85 and efficacy up to 80 lumens per watt (LPW). An OLED luminaire employing 24 of the high performance panels produces practical levels of illumination for general lighting, with a flux of over 2200 lumens at 60 LPW. This is a significant advance in the state of the art for OLED solid-state lighting (SSL), which is expected to be a complementary light source to the more advanced LED SSL technology that is rapidly replacing all other traditional forms of lighting.

  1. The path toward HEP High Performance Computing

    International Nuclear Information System (INIS)

    Apostolakis, John; Brun, René; Gheata, Andrei; Wenzel, Sandro; Carminati, Federico

    2014-01-01

    High Energy Physics code has been known for making poor use of high performance computing architectures. Efforts in optimising HEP code on vector and RISC architectures have yield limited results and recent studies have shown that, on modern architectures, it achieves a performance between 10% and 50% of the peak one. Although several successful attempts have been made to port selected codes on GPUs, no major HEP code suite has a 'High Performance' implementation. With LHC undergoing a major upgrade and a number of challenging experiments on the drawing board, HEP cannot any longer neglect the less-than-optimal performance of its code and it has to try making the best usage of the hardware. This activity is one of the foci of the SFT group at CERN, which hosts, among others, the Root and Geant4 project. The activity of the experiments is shared and coordinated via a Concurrency Forum, where the experience in optimising HEP code is presented and discussed. Another activity is the Geant-V project, centred on the development of a highperformance prototype for particle transport. Achieving a good concurrency level on the emerging parallel architectures without a complete redesign of the framework can only be done by parallelizing at event level, or with a much larger effort at track level. Apart the shareable data structures, this typically implies a multiplication factor in terms of memory consumption compared to the single threaded version, together with sub-optimal handling of event processing tails. Besides this, the low level instruction pipelining of modern processors cannot be used efficiently to speedup the program. We have implemented a framework that allows scheduling vectors of particles to an arbitrary number of computing resources in a fine grain parallel approach. The talk will review the current optimisation activities within the SFT group with a particular emphasis on the development perspectives towards a simulation framework able to profit

  2. Therapy with mesenchymal stromal cells or conditioned medium reverse cardiac alterations in a high-fat diet-induced obesity model.

    Science.gov (United States)

    Daltro, P S; Barreto, B C; Silva, P G; Neto, P Chenaud; Sousa Filho, P H F; Santana Neta, D; Carvalho, G B; Silva, D N; Paredes, B D; de Alcantara, A C; Freitas, L A R; Couto, R D; Santos, R R; Souza, B S F; Soares, M B P; Macambira, S G

    2017-10-01

    Obesity is associated with numerous cardiac complications, including arrhythmias, cardiac fibrosis, remodeling and heart failure. Here we evaluated the therapeutic potential of mesenchymal stromal cells (MSCs) and their conditioned medium (CM) to treat cardiac complications in a mouse model of high-fat diet (HFD)-induced obesity. After obesity induction and HFD withdrawal, obese mice were treated with MSCs, CM or vehicle. Cardiac function was assessed using electrocardiography, echocardiography and treadmill test. Body weight and biochemical parameters were evaluated. Cardiac tissue was used for real time (RT)-polymerase chain reaction (PCR) and histopathologic analysis. Characterization of CM by protein array showed the presence of different cytokines and growth factors, including chemokines, osteopontin, cystatin C, Serpin E1 and Gas 6. HFD-fed mice presented cardiac arrhythmias, altered cardiac gene expression and fibrosis reflected in physical exercise incapacity associated with obesity and diabetes. Administration of MSCs or CM improved arrhythmias and exercise capacity. This functional improvement correlated with normalization of GATA4 gene expression in the hearts of MSC- or CM-treated mice. The gene expression of connexin 43, troponin I, adiponectin, transforming growth factor (TGF) β, peroxisome proliferator activated receptor gamma (PPARγ), insulin-like growth factor 1 (IGF-1), matrix metalloproteinase-9 (MMP9) and tissue inhibitor of metalloproteinases 1 (TIMP1) were significantly reduced in MSCs, but not in CM-treated mice. Moreover, MSC or CM administration reduced the intensity of cardiac fibrosis. Our results suggest that MSCs and CM have a recovery effect on cardiac disturbances due to obesity and corroborate to the paracrine action of MSCs in heart disease models. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  3. Cardiac rehabilitation

    Science.gov (United States)

    ... rehab; Heart failure - cardiac rehab References Anderson L, Taylor RS. Cardiac rehabilitation for people with heart disease: ... of Medicine, Division of Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed ...

  4. In-Vivo Synthetic Aperture and Plane Wave High Frame Rate Cardiac Imaging

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Jensen, Jonas; Brandt, Andreas Hjelm

    2014-01-01

    A comparison of synthetic aperture imaging using spherical and plane waves with low number of emission events is presented. For both wave types, a 90 degree sector is insonified using 15 emission events giving a frame rate of 200 frames per second. Field II simulations of point targets show simil.......43 for spherical and 0.70 for plane waves. All measures are well within FDA limits for cardiac imaging. In-vivo images of the heart of a healthy 28-year old volunteer are shown....

  5. High prevalence of cardiac involvement in patients with myotonic dystrophy type 1

    DEFF Research Database (Denmark)

    Petri, Helle; Witting, Nanna; Ersbøll, Mads Kristian

    2014-01-01

    of controls. Thus, the optimal strategy for assessing cardiac involvement in DM1 is unclear. METHOD: In this large single-centre study, we evaluated 129 unselected DM1 patients (49.6% men), mean (SD) age 44 (14.7) years with family history, physical examination, electrocardiogram (ECG), echocardiography......) arrhythmias: atrial fibrillation/flutter (4.1%), other supraventricular tachyarrhythmia (7.3%) and non-sustained ventricular tachycardia (4.1%); and 3) structural abnormalities: left ventricular systolic dysfunction (20.6%) and reduced global longitudinal strain (21.7%). A normal ECG was not significantly...

  6. A High Performance COTS Based Computer Architecture

    Science.gov (United States)

    Patte, Mathieu; Grimoldi, Raoul; Trautner, Roland

    2014-08-01

    Using Commercial Off The Shelf (COTS) electronic components for space applications is a long standing idea. Indeed the difference in processing performance and energy efficiency between radiation hardened components and COTS components is so important that COTS components are very attractive for use in mass and power constrained systems. However using COTS components in space is not straightforward as one must account with the effects of the space environment on the COTS components behavior. In the frame of the ESA funded activity called High Performance COTS Based Computer, Airbus Defense and Space and its subcontractor OHB CGS have developed and prototyped a versatile COTS based architecture for high performance processing. The rest of the paper is organized as follows: in a first section we will start by recapitulating the interests and constraints of using COTS components for space applications; then we will briefly describe existing fault mitigation architectures and present our solution for fault mitigation based on a component called the SmartIO; in the last part of the paper we will describe the prototyping activities executed during the HiP CBC project.

  7. Management issues for high performance storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Louis, S. [Lawrence Livermore National Lab., CA (United States); Burris, R. [Oak Ridge National Lab., TN (United States)

    1995-03-01

    Managing distributed high-performance storage systems is complex and, although sharing common ground with traditional network and systems management, presents unique storage-related issues. Integration technologies and frameworks exist to help manage distributed network and system environments. Industry-driven consortia provide open forums where vendors and users cooperate to leverage solutions. But these new approaches to open management fall short addressing the needs of scalable, distributed storage. We discuss the motivation and requirements for storage system management (SSM) capabilities and describe how SSM manages distributed servers and storage resource objects in the High Performance Storage System (HPSS), a new storage facility for data-intensive applications and large-scale computing. Modem storage systems, such as HPSS, require many SSM capabilities, including server and resource configuration control, performance monitoring, quality of service, flexible policies, file migration, file repacking, accounting, and quotas. We present results of initial HPSS SSM development including design decisions and implementation trade-offs. We conclude with plans for follow-on work and provide storage-related recommendations for vendors and standards groups seeking enterprise-wide management solutions.

  8. Automatic Energy Schemes for High Performance Applications

    Energy Technology Data Exchange (ETDEWEB)

    Sundriyal, Vaibhav [Iowa State Univ., Ames, IA (United States)

    2013-01-01

    Although high-performance computing traditionally focuses on the efficient execution of large-scale applications, both energy and power have become critical concerns when approaching exascale. Drastic increases in the power consumption of supercomputers affect significantly their operating costs and failure rates. In modern microprocessor architectures, equipped with dynamic voltage and frequency scaling (DVFS) and CPU clock modulation (throttling), the power consumption may be controlled in software. Additionally, network interconnect, such as Infiniband, may be exploited to maximize energy savings while the application performance loss and frequency switching overheads must be carefully balanced. This work first studies two important collective communication operations, all-to-all and allgather and proposes energy saving strategies on the per-call basis. Next, it targets point-to-point communications to group them into phases and apply frequency scaling to them to save energy by exploiting the architectural and communication stalls. Finally, it proposes an automatic runtime system which combines both collective and point-to-point communications into phases, and applies throttling to them apart from DVFS to maximize energy savings. The experimental results are presented for NAS parallel benchmark problems as well as for the realistic parallel electronic structure calculations performed by the widely used quantum chemistry package GAMESS. Close to the maximum energy savings were obtained with a substantially low performance loss on the given platform.

  9. High-performance computing in seismology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    The scientific, technical, and economic importance of the issues discussed here presents a clear agenda for future research in computational seismology. In this way these problems will drive advances in high-performance computing in the field of seismology. There is a broad community that will benefit from this work, including the petroleum industry, research geophysicists, engineers concerned with seismic hazard mitigation, and governments charged with enforcing a comprehensive test ban treaty. These advances may also lead to new applications for seismological research. The recent application of high-resolution seismic imaging of the shallow subsurface for the environmental remediation industry is an example of this activity. This report makes the following recommendations: (1) focused efforts to develop validated documented software for seismological computations should be supported, with special emphasis on scalable algorithms for parallel processors; (2) the education of seismologists in high-performance computing technologies and methodologies should be improved; (3) collaborations between seismologists and computational scientists and engineers should be increased; (4) the infrastructure for archiving, disseminating, and processing large volumes of seismological data should be improved.

  10. A high performance architecture for accelerator controls

    International Nuclear Information System (INIS)

    Allen, M.; Hunt, S.M; Lue, H.; Saltmarsh, C.G.; Parker, C.R.C.B.

    1991-01-01

    The demands placed on the Superconducting Super Collider (SSC) control system due to large distances, high bandwidth and fast response time required for operation will require a fresh approach to the data communications architecture of the accelerator. The prototype design effort aims at providing deterministic communication across the accelerator complex with a response time of < 100 ms and total bandwidth of 2 Gbits/sec. It will offer a consistent interface for a large number of equipment types, from vacuum pumps to beam position monitors, providing appropriate communications performance for each equipment type. It will consist of highly parallel links to all equipment: those with computing resources, non-intelligent direct control interfaces, and data concentrators. This system will give each piece of equipment a dedicated link of fixed bandwidth to the control system. Application programs will have access to all accelerator devices which will be memory mapped into a global virtual addressing scheme. Links to devices in the same geographical area will be multiplexed using commercial Time Division Multiplexing equipment. Low-level access will use reflective memory techniques, eliminating processing overhead and complexity of traditional data communication protocols. The use of commercial standards and equipment will enable a high performance system to be built at low cost

  11. A high performance architecture for accelerator controls

    International Nuclear Information System (INIS)

    Allen, M.; Hunt, S.M.; Lue, H.; Saltmarsh, C.G.; Parker, C.R.C.B.

    1991-03-01

    The demands placed on the Superconducting Super Collider (SSC) control system due to large distances, high bandwidth and fast response time required for operation will require a fresh approach to the data communications architecture of the accelerator. The prototype design effort aims at providing deterministic communication across the accelerator complex with a response time of <100 ms and total bandwidth of 2 Gbits/sec. It will offer a consistent interface for a large number of equipment types, from vacuum pumps to beam position monitors, providing appropriate communications performance for each equipment type. It will consist of highly parallel links to all equipments: those with computing resources, non-intelligent direct control interfaces, and data concentrators. This system will give each piece of equipment a dedicated link of fixed bandwidth to the control system. Application programs will have access to all accelerator devices which will be memory mapped into a global virtual addressing scheme. Links to devices in the same geographical area will be multiplexed using commercial Time Division Multiplexing equipment. Low-level access will use reflective memory techniques, eliminating processing overhead and complexity of traditional data communication protocols. The use of commercial standards and equipment will enable a high performance system to be built at low cost. 1 fig

  12. High performance computing in linear control

    International Nuclear Information System (INIS)

    Datta, B.N.

    1993-01-01

    Remarkable progress has been made in both theory and applications of all important areas of control. The theory is rich and very sophisticated. Some beautiful applications of control theory are presently being made in aerospace, biomedical engineering, industrial engineering, robotics, economics, power systems, etc. Unfortunately, the same assessment of progress does not hold in general for computations in control theory. Control Theory is lagging behind other areas of science and engineering in this respect. Nowadays there is a revolution going on in the world of high performance scientific computing. Many powerful computers with vector and parallel processing have been built and have been available in recent years. These supercomputers offer very high speed in computations. Highly efficient software, based on powerful algorithms, has been developed to use on these advanced computers, and has also contributed to increased performance. While workers in many areas of science and engineering have taken great advantage of these hardware and software developments, control scientists and engineers, unfortunately, have not been able to take much advantage of these developments

  13. Building Trust in High-Performing Teams

    Directory of Open Access Journals (Sweden)

    Aki Soudunsaari

    2012-06-01

    Full Text Available Facilitation of growth is more about good, trustworthy contacts than capital. Trust is a driving force for business creation, and to create a global business you need to build a team that is capable of meeting the challenge. Trust is a key factor in team building and a needed enabler for cooperation. In general, trust building is a slow process, but it can be accelerated with open interaction and good communication skills. The fast-growing and ever-changing nature of global business sets demands for cooperation and team building, especially for startup companies. Trust building needs personal knowledge and regular face-to-face interaction, but it also requires empathy, respect, and genuine listening. Trust increases communication, and rich and open communication is essential for the building of high-performing teams. Other building materials are a shared vision, clear roles and responsibilities, willingness for cooperation, and supporting and encouraging leadership. This study focuses on trust in high-performing teams. It asks whether it is possible to manage trust and which tools and operation models should be used to speed up the building of trust. In this article, preliminary results from the authors’ research are presented to highlight the importance of sharing critical information and having a high level of communication through constant interaction.

  14. Impact of attributed audit on procedural performance in cardiac electrophysiology catheter laboratory.

    Science.gov (United States)

    Sawhney, V; Volkova, E; Shaukat, M; Khan, F; Segal, O; Ahsan, S; Chow, A; Ezzat, V; Finlay, M; Lambiase, P; Lowe, M; Dhinoja, M; Sporton, S; Earley, M J; Hunter, R J; Schilling, R J

    2018-06-01

    Audit has played a key role in monitoring and improving clinical practice. However, audit often fails to drive change as summative institutional data alone may be insufficient to do so. We hypothesised that the practice of attributed audit, wherein each individual's procedural performance is presented will have a greater impact on clinical practice. This hypothesis was tested in an observational study evaluating improvement in fluoroscopy times for AF ablation. Retrospective analyses of fluoroscopy times in AF ablations at the Barts Heart Centre (BHC) from 2012-2017. Fluoroscopy times were compared pre- and post- the introduction of attributed audit in 2012 at St Bartholomew's Hospital (SBH). In order to test the hypothesis, this concept was introduced to a second group of experienced operators from the Heart Hospital (HH) as part of a merger of the two institutions in 2015 and change in fluoroscopy times recorded. A significant drop in fluoroscopy times (33.3 ± 9.14 to 8.95 ± 2.50, p audit. At the time of merger, a significant difference in fluoroscopy times between operators from the two centres was seen in 2015. Each operator's procedural performance was shared openly at the audit meeting. Subsequent audits showed a steady decrease in fluoroscopy times for each operator with the fluoroscopy time (min, mean±SD) decreasing from 13.29 ± 7.3 in 2015 to 8.84 ± 4.8 (p audit can promptsignificant improvement and hence should be adopted in clinical practice.

  15. Improving UV Resistance of High Performance Fibers

    Science.gov (United States)

    Hassanin, Ahmed

    High performance fibers are characterized by their superior properties compared to the traditional textile fibers. High strength fibers have high modules, high strength to weight ratio, high chemical resistance, and usually high temperature resistance. It is used in application where superior properties are needed such as bulletproof vests, ropes and cables, cut resistant products, load tendons for giant scientific balloons, fishing rods, tennis racket strings, parachute cords, adhesives and sealants, protective apparel and tire cords. Unfortunately, Ultraviolet (UV) radiation causes serious degradation to the most of high performance fibers. UV lights, either natural or artificial, cause organic compounds to decompose and degrade, because the energy of the photons of UV light is high enough to break chemical bonds causing chain scission. This work is aiming at achieving maximum protection of high performance fibers using sheathing approaches. The sheaths proposed are of lightweight to maintain the advantage of the high performance fiber that is the high strength to weight ratio. This study involves developing three different types of sheathing. The product of interest that need be protected from UV is braid from PBO. First approach is extruding a sheath from Low Density Polyethylene (LDPE) loaded with different rutile TiO2 % nanoparticles around the braid from the PBO. The results of this approach showed that LDPE sheath loaded with 10% TiO2 by weight achieved the highest protection compare to 0% and 5% TiO2. The protection here is judged by strength loss of PBO. This trend noticed in different weathering environments, where the sheathed samples were exposed to UV-VIS radiations in different weatheromter equipments as well as exposure to high altitude environment using NASA BRDL balloon. The second approach is focusing in developing a protective porous membrane from polyurethane loaded with rutile TiO2 nanoparticles. Membrane from polyurethane loaded with 4

  16. Intel Xeon Phi coprocessor high performance programming

    CERN Document Server

    Jeffers, James

    2013-01-01

    Authors Jim Jeffers and James Reinders spent two years helping educate customers about the prototype and pre-production hardware before Intel introduced the first Intel Xeon Phi coprocessor. They have distilled their own experiences coupled with insights from many expert customers, Intel Field Engineers, Application Engineers and Technical Consulting Engineers, to create this authoritative first book on the essentials of programming for this new architecture and these new products. This book is useful even before you ever touch a system with an Intel Xeon Phi coprocessor. To ensure that your applications run at maximum efficiency, the authors emphasize key techniques for programming any modern parallel computing system whether based on Intel Xeon processors, Intel Xeon Phi coprocessors, or other high performance microprocessors. Applying these techniques will generally increase your program performance on any system, and better prepare you for Intel Xeon Phi coprocessors and the Intel MIC architecture. It off...

  17. Development of high-performance blended cements

    Science.gov (United States)

    Wu, Zichao

    2000-10-01

    This thesis presents the development of high-performance blended cements from industrial by-products. To overcome the low-early strength of blended cements, several chemicals were studied as the activators for cement hydration. Sodium sulfate was discovered as the best activator. The blending proportions were optimized by Taguchi experimental design. The optimized blended cements containing up to 80% fly ash performed better than Type I cement in strength development and durability. Maintaining a constant cement content, concrete produced from the optimized blended cements had equal or higher strength and higher durability than that produced from Type I cement alone. The key for the activation mechanism was the reaction between added SO4 2- and Ca2+ dissolved from cement hydration products.

  18. Cardiac sympathetic neuronal imaging using PET

    International Nuclear Information System (INIS)

    Lautamaeki, Riikka; Tipre, Dnyanesh; Bengel, Frank M.

    2007-01-01

    Balance of the autonomic nervous system is essential for adequate cardiac performance, and alterations seem to play a key role in the development and progression of various cardiac diseases. PET imaging of the cardiac autonomic nervous system has advanced extensively in recent years, and multiple pre- and postsynaptic tracers have been introduced. The high spatial and temporal resolution of PET enables noninvasive quantification of neurophysiologic processes at the tissue level. Ligands for catecholamine receptors, along with radiolabeled catecholamines and catecholamine analogs, have been applied to determine involvement of sympathetic dysinnervation at different stages of heart diseases such as ischemia, heart failure, and arrhythmia. This review summarizes the recent findings in neurocardiological PET imaging. Experimental studies with several radioligands and clinical findings in cardiac dysautonomias are discussed. (orig.)

  19. Estimation of children's radiation dose from cardiac catheterisations, performed for the diagnosis or the treatment of a congenital heart disease using TLD dosimetry and Monte Carlo simulation

    International Nuclear Information System (INIS)

    Yakoumakis, E N; Gialousis, G I; Papadopoulou, Despina; Makri, Triantafillia; Pappouli, Zografia; Yakoumakis, Nikolaos; Papagiannis, Panayotis; Georgiou, Evangelos

    2009-01-01

    Entrance surface radiation doses were measured with thermoluminescent dosimeters for 98 children who were referred to a cardiology department for the diagnosis or the treatment of a congenital heart disease. Additionally, all the radiographic parameters were recorded and Monte Carlo simulations were performed for the estimation of entrance surface dose to effective dose conversion factors, in order to further calculate the effective dose for each child. For diagnostic catheterisations the values ranged from 0.16 to 14.44 mSv, with average 3.71 mSv, and for therapeutic catheterisations the values ranged from 0.38 to 25.01 mSv, with average value 5 mSv. Effective doses were estimated for diagnostic procedures and interventional procedures performed for the treatment of five different heart diseases: (a) atrial septal defect (ASD), (b) ventricular septal defect (VSD), (c) patent ductus arteriosus (PDA), (d) aorta coarctation and (e) pulmonary stenosis. The high levels of radiation exposure are, however, balanced with the advantages of cardiac catheterisations such as the avoidance of surgical closure and the necessity of shorter or even no hospitalisation.

  20. Estimation of children's radiation dose from cardiac catheterisations, performed for the diagnosis or the treatment of a congenital heart disease using TLD dosimetry and Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Yakoumakis, E N; Gialousis, G I; Papadopoulou, Despina; Makri, Triantafillia; Pappouli, Zografia; Yakoumakis, Nikolaos; Papagiannis, Panayotis; Georgiou, Evangelos [Medical Physics Department, University of Athens, 75 Mikras Asias Street, Athens 11527 (Greece)

    2009-06-15

    Entrance surface radiation doses were measured with thermoluminescent dosimeters for 98 children who were referred to a cardiology department for the diagnosis or the treatment of a congenital heart disease. Additionally, all the radiographic parameters were recorded and Monte Carlo simulations were performed for the estimation of entrance surface dose to effective dose conversion factors, in order to further calculate the effective dose for each child. For diagnostic catheterisations the values ranged from 0.16 to 14.44 mSv, with average 3.71 mSv, and for therapeutic catheterisations the values ranged from 0.38 to 25.01 mSv, with average value 5 mSv. Effective doses were estimated for diagnostic procedures and interventional procedures performed for the treatment of five different heart diseases: (a) atrial septal defect (ASD), (b) ventricular septal defect (VSD), (c) patent ductus arteriosus (PDA), (d) aorta coarctation and (e) pulmonary stenosis. The high levels of radiation exposure are, however, balanced with the advantages of cardiac catheterisations such as the avoidance of surgical closure and the necessity of shorter or even no hospitalisation.

  1. Utilities for high performance dispersion model PHYSIC

    International Nuclear Information System (INIS)

    Yamazawa, Hiromi

    1992-09-01

    The description and usage of the utilities for the dispersion calculation model PHYSIC were summarized. The model was developed in the study of developing high performance SPEEDI with the purpose of introducing meteorological forecast function into the environmental emergency response system. The procedure of PHYSIC calculation consists of three steps; preparation of relevant files, creation and submission of JCL, and graphic output of results. A user can carry out the above procedure with the help of the Geographical Data Processing Utility, the Model Control Utility, and the Graphic Output Utility. (author)

  2. An integrated high performance fastbus slave interface

    International Nuclear Information System (INIS)

    Christiansen, J.; Ljuslin, C.

    1992-01-01

    A high performance Fastbus slave interface ASIC is presented. The Fastbus slave integrated circuit (FASIC) is a programmable device, enabling its direct use in many different applications. The FASIC acts as an interface between Fastbus and a 'standard' processor/memory bus. It can work stand-alone or together with a microprocessor. A set of address mapping windows can map Fastbus addresses to convenient memory addresses and at the same time act as address decoding logic. Data rates of 100 MBytes/s to Fastbus can be obtained using an internal FIFO buffer in the FASIC. (orig.)

  3. High performance visual display for HENP detectors

    CERN Document Server

    McGuigan, M; Spiletic, J; Fine, V; Nevski, P

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactiv...

  4. High-Performance Vertical Organic Electrochemical Transistors.

    Science.gov (United States)

    Donahue, Mary J; Williamson, Adam; Strakosas, Xenofon; Friedlein, Jacob T; McLeod, Robert R; Gleskova, Helena; Malliaras, George G

    2018-02-01

    Organic electrochemical transistors (OECTs) are promising transducers for biointerfacing due to their high transconductance, biocompatibility, and availability in a variety of form factors. Most OECTs reported to date, however, utilize rather large channels, limiting the transistor performance and resulting in a low transistor density. This is typically a consequence of limitations associated with traditional fabrication methods and with 2D substrates. Here, the fabrication and characterization of OECTs with vertically stacked contacts, which overcome these limitations, is reported. The resulting vertical transistors exhibit a reduced footprint, increased intrinsic transconductance of up to 57 mS, and a geometry-normalized transconductance of 814 S m -1 . The fabrication process is straightforward and compatible with sensitive organic materials, and allows exceptional control over the transistor channel length. This novel 3D fabrication method is particularly suited for applications where high density is needed, such as in implantable devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Correlation of cardiac performance with cellular energetic components in the oxygen-deprived turtle heart

    DEFF Research Database (Denmark)

    Stecyk, Jonathan; Bock, Christian; Overgaard, Johannes

    2009-01-01

    of an anoxia-tolerant vertebrate, the freshwater turtle (Trachemys scripta) during long-term anoxia exposure ( 3 h at 21°C and 11 days at 5°C). During anoxia, phosphocreatine (PCr), unbound levels of inorganic phosphate (effective Pi2–), intracellular pH (pHi), and free energy of ATP hydrolysis (d......G/d ) exhibited asymptotic patterns of change, indicating that turtle myocardial high-energy phosphate metabolism and energetic state are reset to new, reduced steady states during long-term anoxia exposure. At 21°C, anoxia caused a reduction in pHi from 7.40 to 7.01, a 69% decrease in PCr and a doubling...

  6. Factoring socioeconomic status into cardiac performance profiling for hospitals: does it matter?

    Science.gov (United States)

    Alter, David A; Austin, Peter C; Naylor, C David; Tu, Jack V

    2002-01-01

    Critics of "scorecard medicine" often highlight the incompleteness of risk-adjustment methods used when accounting for baseline patient differences. Although socioeconomic status is a highly important determinant of adverse outcome for patients admitted to the hospital with acute myocardial infarction, it has not been used in most risk-adjustment models for cardiovascular report cards. To determine the incremental impact of socioeconomic status adjustments on age, sex, and illness severity for hospital-specific 30-day mortality rates after acute myocardial infarction. The authors compared the absolute and relative hospital-specific 30-day acute myocardial infarction mortality rates in 169 hospitals throughout Ontario between April 1, 1994 and March 31, 1997. Patient socioeconomic status was characterized by median neighborhood income using postal codes and 1996 Canadian census data. They examined two risk-adjustment models: the first adjusted for age, sex, and illness severity (standard), whereas the second adjusted for age, sex, illness severity, and median neighborhood income level (socioeconomic status). There was an extremely strong correlation between 'standard' and 'socioeconomic status' risk-adjusted mortality rates (r = 0.99). Absolute differences in 30-day risk-adjusted mortality rates between the socioeconomic status and standard risk-adjustment models were small (median, 0.1%; 25th-75th percentile, 0.1-0.2). The agreement in the quintile rankings of hospitals between the socioeconomic status and standard risk-adjustment models was high (weighted kappa = 0.93). Despite its importance as a determinant of patient outcomes, the effect of socioeconomic status on hospital-specific mortality rates over and above standard risk-adjustment methods for acute myocardial infarction hospital profiling in Ontario was negligible.

  7. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    International Nuclear Information System (INIS)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  8. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure.

    Science.gov (United States)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-05-01

    Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the

  9. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Joscha, E-mail: joscha.maier@dkfz.de [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Sawall, Stefan; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, University of Erlangen–Nürnberg, 91052 Erlangen (Germany)

    2014-05-15

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  10. High Performance Data Distribution for Scientific Community

    Science.gov (United States)

    Tirado, Juan M.; Higuero, Daniel; Carretero, Jesus

    2010-05-01

    Institutions such as NASA, ESA or JAXA find solutions to distribute data from their missions to the scientific community, and their long term archives. This is a complex problem, as it includes a vast amount of data, several geographically distributed archives, heterogeneous architectures with heterogeneous networks, and users spread around the world. We propose a novel architecture (HIDDRA) that solves this problem aiming to reduce user intervention in data acquisition and processing. HIDDRA is a modular system that provides a highly efficient parallel multiprotocol download engine, using a publish/subscribe policy which helps the final user to obtain data of interest transparently. Our system can deal simultaneously with multiple protocols (HTTP,HTTPS, FTP, GridFTP among others) to obtain the maximum bandwidth, reducing the workload in data server and increasing flexibility. It can also provide high reliability and fault tolerance, as several sources of data can be used to perform one file download. HIDDRA architecture can be arranged into a data distribution network deployed on several sites that can cooperate to provide former features. HIDDRA has been addressed by the 2009 e-IRG Report on Data Management as a promising initiative for data interoperability. Our first prototype has been evaluated in collaboration with the ESAC centre in Villafranca del Castillo (Spain) that shows a high scalability and performance, opening a wide spectrum of opportunities. Some preliminary results have been published in the Journal of Astrophysics and Space Science [1]. [1] D. Higuero, J.M. Tirado, J. Carretero, F. Félix, and A. de La Fuente. HIDDRA: a highly independent data distribution and retrieval architecture for space observation missions. Astrophysics and Space Science, 321(3):169-175, 2009

  11. High-intensity interval training versus moderate-intensity continuous training within cardiac rehabilitation: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Hannan AL

    2018-01-01

    Full Text Available Amanda L Hannan,1 Wayne Hing,1 Vini Simas,1 Mike Climstein,2,3 Jeff S Coombes,4 Rohan Jayasinghe,5–7 Joshua Byrnes,8 James Furness1 1Faculty of Health Sciences & Medicine, Bond University, Gold Coast, QLD, Australia; 2Exercise Health and Performance Faculty Research Group, Faculty of Health Sciences, The University of Sydney, Sydney, NSW, Australia; 3Water Based Research Unit, Bond University, Gold Coast, QLD, Australia; 4School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, QLD, Australia; 5Cardiology Department, Gold Coast University Hospital, Gold Coast, QLD, Australia; 6Griffith University, Gold Coast, QLD, Australia; 7Macquarie University, Sydney, NSW, Australia; 8Centre for Applied Health Economics, School of Medicine, Griffith University, Logan, QLD, Australia Background: Aerobic capacity has been shown to be inversely proportionate to cardiovascular mortality and morbidity and there is growing evidence that high-intensity interval training (HIIT appears to be more effective than moderate-intensity continuous training (MICT in improving cardiorespiratory fitness within the cardiac population. Previously published systematic reviews in cardiovascular disease have neither investigated the effect that the number of weeks of intervention has on cardiorespiratory fitness changes, nor have adverse events been collated. Objective: We aimed to undertake a systematic review and meta-analysis of randomized controlled trials (RCTs within the cardiac population that investigated cardiorespiratory fitness changes resulting from HIIT versus MICT and to collate adverse events. Methods: A critical narrative synthesis and meta-analysis was conducted after systematically searching relevant databases up to July 2017. We searched for RCTs that compared cardiorespiratory fitness changes resulting from HIIT versus MICT interventions within the cardiac population. Results: Seventeen studies, involving 953 participants (465

  12. High-performance laboratories and cleanrooms; TOPICAL

    International Nuclear Information System (INIS)

    Tschudi, William; Sartor, Dale; Mills, Evan; Xu, Tengfang

    2002-01-01

    The California Energy Commission sponsored this roadmap to guide energy efficiency research and deployment for high performance cleanrooms and laboratories. Industries and institutions utilizing these building types (termed high-tech buildings) have played an important part in the vitality of the California economy. This roadmap's key objective to present a multi-year agenda to prioritize and coordinate research efforts. It also addresses delivery mechanisms to get the research products into the market. Because of the importance to the California economy, it is appropriate and important for California to take the lead in assessing the energy efficiency research needs, opportunities, and priorities for this market. In addition to the importance to California's economy, energy demand for this market segment is large and growing (estimated at 9400 GWH for 1996, Mills et al. 1996). With their 24hr. continuous operation, high tech facilities are a major contributor to the peak electrical demand. Laboratories and cleanrooms constitute the high tech building market, and although each building type has its unique features, they are similar in that they are extremely energy intensive, involve special environmental considerations, have very high ventilation requirements, and are subject to regulations-primarily safety driven-that tend to have adverse energy implications. High-tech buildings have largely been overlooked in past energy efficiency research. Many industries and institutions utilize laboratories and cleanrooms. As illustrated, there are many industries operating cleanrooms in California. These include semiconductor manufacturing, semiconductor suppliers, pharmaceutical, biotechnology, disk drive manufacturing, flat panel displays, automotive, aerospace, food, hospitals, medical devices, universities, and federal research facilities

  13. Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT.

    Science.gov (United States)

    Sommer, Wieland H; Albrecht, Edda; Bamberg, Fabian; Schenzle, Jan C; Johnson, Thorsten R; Neumaier, Klement; Reiser, Maximilian F; Nikolaou, Konstatin

    2010-12-01

    The objective of this study was to compare image quality and radiation dose between high-pitch and established retrospectively and prospectively gated cardiac CT protocols using an Alderson-Rando phantom and a set of patients. An anthropomorphic Alderson-Rando phantom equipped with thermoluminiscent detectors and a set of clinical patients underwent the following cardiac CT protocols: high-pitch acquisition (pitch 3.4), prospectively triggered acquisition, and retrospectively gated acquisition (pitch 0.2). For patients with sinus rhythm below 65 beats per minute (bpm), high-pitch protocol was used, whereas for patients in sinus rhythm between 65 and 100 bpm, prospective triggering was used. Patients with irregular heart rates or heart rates of ≥ 100 bpm, were examined using retrospectively gated acquisition. Evaluability of coronary artery segments was determined, and effective radiation dose was derived from the phantom study. In the phantom study, the effective radiation dose as determined with thermoluminescent detector (TLD) measurements was lowest in the high-pitch acquisition (1.21, 3.12, and 11.81 mSv, for the high-pitch, the prospectively triggered, and the retrospectively gated acquisition, respectively). There was a significant difference with respect to the percentage of motion-free coronary artery segments (99%, 87%, and 92% for high-pitch, prospectively triggered, and retrospectively gated, respectively (p pitch protocol (p pitch scans have the potential to reduce radiation dose up to 61.2% and 89.8% compared with prospectively triggered and retrospectively gated scans. High-pitch protocols lead to excellent image quality when used in patients with stable heart rates below 65 bpm.

  14. High intensity interval and endurance training have opposing effects on markers of heart failure and cardiac remodeling in hypertensive rats.

    Directory of Open Access Journals (Sweden)

    Tanya M Holloway

    Full Text Available There has been re-emerging interest and significant work dedicated to investigating the metabolic effects of high intensity interval training (HIIT in recent years. HIIT is considered to be a time efficient alternative to classic endurance training (ET that elicits similar metabolic responses in skeletal muscle. However, there is a lack of information on the impact of HIIT on cardiac muscle in disease. Therefore, we determined the efficacy of ET and HIIT to alter cardiac muscle characteristics involved in the development of diastolic dysfunction, such as ventricular hypertrophy, fibrosis and angiogenesis, in a well-established rodent model of hypertension-induced heart failure before the development of overt heart failure. ET decreased left ventricle fibrosis by ~40% (P < 0.05, and promoted a 20% (P<0.05 increase in the left ventricular capillary/fibre ratio, an increase in endothelial nitric oxide synthase protein (P<0.05, and a decrease in hypoxia inducible factor 1 alpha protein content (P<0.05. In contrast, HIIT did not decrease existing fibrosis, and HIIT animals displayed a 20% increase in left ventricular mass (P<0.05 and a 20% decrease in cross sectional area (P<0.05. HIIT also increased brain natriuretic peptide by 50% (P<0.05, in the absence of concomitant angiogenesis, strongly suggesting pathological cardiac remodeling. The current data support the longstanding belief in the effectiveness of ET in hypertension. However, HIIT promoted a pathological adaptation in the left ventricle in the presence of hypertension, highlighting the need for further research on the widespread effects of HIIT in the presence of disease.

  15. Incidence, microbiological profile of nosocomial infections, and their antibiotic resistance patterns in a high volume Cardiac Surgical Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Manoj Kumar Sahu

    2016-01-01

    Full Text Available Background: Nosocomial infections (NIs in the postoperative period not only increase morbidity and mortality, but also impose a significant economic burden on the health care infrastructure. This retrospective study was undertaken to (a evaluate the incidence, characteristics, risk factors and outcomes of NIs and (b identify common microorganisms responsible for infection and their antibiotic resistance profile in our Cardiac Surgical Intensive Care Unit (CSICU. Patients and Methods: After ethics committee approval, the CSICU records of all patients who underwent cardiovascular surgery between January 2013 and December 2014 were reviewed retrospectively. The incidence of NI, distribution of NI sites, types of microorganisms and their antibiotic resistance, length of CSICU stay, and patient-outcome were determined. Results: Three hundred and nineteen of 6864 patients (4.6% developed NI after cardiac surgery. Lower respiratory tract infections (LRTIs accounted for most of the infections (44.2% followed by surgical-site infection (SSI, 11.6%, bloodstream infection (BSI, 7.5%, urinary tract infection (UTI, 6.9% and infections from combined sources (29.8%. Acinetobacter, Klebsiella, Escherichia coli, and Staphylococcus were the most frequent pathogens isolated in patients with LRTI, BSI, UTI, and SSI, respectively. The Gram-negative bacteria isolated from different sources were found to be highly resistant to commonly used antibiotics. Conclusion: The incidence of NI and sepsis-related mortality, in our CSICU, was 4.6% and 1.9%, respectively. Lower respiratory tract was the most common site of infection and Gram-negative bacilli, the most common pathogens after cardiac surgery. Antibiotic resistance was maximum with Acinetobacter spp.

  16. Transport in JET high performance plasmas

    International Nuclear Information System (INIS)

    2001-01-01

    Two type of high performance scenarios have been produced in JET during DTE1 campaign. One of them is the well known and extensively used in the past ELM-free hot ion H-mode scenario which has two distinct regions- plasma core and the edge transport barrier. The results obtained during DTE-1 campaign with D, DT and pure T plasmas confirms our previous conclusion that the core transport scales as a gyroBohm in the inner half of plasma volume, recovers its Bohm nature closer to the separatrix and behaves as ion neoclassical in the transport barrier. Measurements on the top of the barrier suggest that the width of the barrier is dependent upon isotope and moreover suggest that fast ions play a key role. The other high performance scenario is a relatively recently developed Optimised Shear Scenario with small or slightly negative magnetic shear in plasma core. Different mechanisms of Internal Transport Barrier (ITB) formation have been tested by predictive modelling and the results are compared with experimentally observed phenomena. The experimentally observed non-penetration of the heavy impurities through the strong ITB which contradicts to a prediction of the conventional neo-classical theory is discussed. (author)

  17. High-performance computing for airborne applications

    International Nuclear Information System (INIS)

    Quinn, Heather M.; Manuzatto, Andrea; Fairbanks, Tom; Dallmann, Nicholas; Desgeorges, Rose

    2010-01-01

    Recently, there has been attempts to move common satellite tasks to unmanned aerial vehicles (UAVs). UAVs are significantly cheaper to buy than satellites and easier to deploy on an as-needed basis. The more benign radiation environment also allows for an aggressive adoption of state-of-the-art commercial computational devices, which increases the amount of data that can be collected. There are a number of commercial computing devices currently available that are well-suited to high-performance computing. These devices range from specialized computational devices, such as field-programmable gate arrays (FPGAs) and digital signal processors (DSPs), to traditional computing platforms, such as microprocessors. Even though the radiation environment is relatively benign, these devices could be susceptible to single-event effects. In this paper, we will present radiation data for high-performance computing devices in a accelerated neutron environment. These devices include a multi-core digital signal processor, two field-programmable gate arrays, and a microprocessor. From these results, we found that all of these devices are suitable for many airplane environments without reliability problems.

  18. Transport in JET high performance plasmas

    International Nuclear Information System (INIS)

    1999-01-01

    Two type of high performance scenarios have been produced in JET during DTE1 campaign. One of them is the well known and extensively used in the past ELM-free hot ion H-mode scenario which has two distinct regions- plasma core and the edge transport barrier. The results obtained during DTE-1 campaign with D, DT and pure T plasmas confirms our previous conclusion that the core transport scales as a gyroBohm in the inner half of plasma volume, recovers its Bohm nature closer to the separatrix and behaves as ion neoclassical in the transport barrier. Measurements on the top of the barrier suggest that the width of the barrier is dependent upon isotope and moreover suggest that fast ions play a key role. The other high performance scenario is a relatively recently developed Optimised Shear Scenario with small or slightly negative magnetic shear in plasma core. Different mechanisms of Internal Transport Barrier (ITB) formation have been tested by predictive modelling and the results are compared with experimentally observed phenomena. The experimentally observed non-penetration of the heavy impurities through the strong ITB which contradicts to a prediction of the conventional neo-classical theory is discussed. (author)

  19. High-performance vertical organic transistors.

    Science.gov (United States)

    Kleemann, Hans; Günther, Alrun A; Leo, Karl; Lüssem, Björn

    2013-11-11

    Vertical organic thin-film transistors (VOTFTs) are promising devices to overcome the transconductance and cut-off frequency restrictions of horizontal organic thin-film transistors. The basic physical mechanisms of VOTFT operation, however, are not well understood and VOTFTs often require complex patterning techniques using self-assembly processes which impedes a future large-area production. In this contribution, high-performance vertical organic transistors comprising pentacene for p-type operation and C60 for n-type operation are presented. The static current-voltage behavior as well as the fundamental scaling laws of such transistors are studied, disclosing a remarkable transistor operation with a behavior limited by injection of charge carriers. The transistors are manufactured by photolithography, in contrast to other VOTFT concepts using self-assembled source electrodes. Fluorinated photoresist and solvent compounds allow for photolithographical patterning directly and strongly onto the organic materials, simplifying the fabrication protocol and making VOTFTs a prospective candidate for future high-performance applications of organic transistors. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. The evaluation of right ventricular performance using krypton-81m multiple-gated equilibrium cardiac blood pool scintigraphy

    International Nuclear Information System (INIS)

    Hosoi, Tsutomu

    1993-01-01

    Technetium-99m first pass angiography and multiple-gated equilibrium blood pool scintigraphy have been used for evaluating right ventricular performance, but both techniques have several methodologic limitations. The activity of kr-81m is exhaled during its transit through the lungs and residual activity in the left heart is negligible. Therefore, right heart study can be performed in the right anterior oblique position with optimal separation between the right ventricle and the right atrium. Thus, the author assessed right ventricular function using Kr-81m multiple-gated equilibrium cardiac blood pool scintigraphy in 40 patients with old myocardial infarction and 9 normal subjects. The patient group included 11 cases of inferior infarction with a significant stenosing lesion proximal to the origin of the right ventricular branch of the right coronary artery (group I), 11 cases of inferior infarction without a significant lesion in the proximal portion of the right coronary artery (group II) and 18 cases of anterior wall infarction (group III). The right ventricular ejection fraction (EF) was 45.6±9.8% in group I, 56.6±5.7% in group II, 55.6±4.4% in group III and 53.7±3.2% in the 9 normal subjects. There were no statistically significant differences among these 4 groups. However, right ventricular EF was significantly reduced in 5 group I patients who had hemodynamic evidence of right ventricular infarction (39.4±9.5%, P<0.01 vs group II, group III and normal subjects). No significant correlation was found between right and left ventricular EF or between right ventricular EF and wall motion abnormality of the interventricular septum. (author)

  1. Performance of the CMS High Level Trigger

    CERN Document Server

    Perrotta, Andrea

    2015-01-01

    The CMS experiment has been designed with a 2-level trigger system. The first level is implemented using custom-designed electronics. The second level is the so-called High Level Trigger (HLT), a streamlined version of the CMS offline reconstruction software running on a computer farm. For Run II of the Large Hadron Collider, the increases in center-of-mass energy and luminosity will raise the event rate to a level challenging for the HLT algorithms. The increase in the number of interactions per bunch crossing, on average 25 in 2012, and expected to be around 40 in Run II, will be an additional complication. We present here the expected performance of the main triggers that will be used during the 2015 data taking campaign, paying particular attention to the new approaches that have been developed to cope with the challenges of the new run. This includes improvements in HLT electron and photon reconstruction as well as better performing muon triggers. We will also present the performance of the improved trac...

  2. Development of a High Performance Spacer Grid

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kee Nam; Song, K. N.; Yoon, K. H. (and others)

    2007-03-15

    A spacer grid in a LWR fuel assembly is a key structural component to support fuel rods and to enhance the heat transfer from the fuel rod to the coolant. In this research, the main research items are the development of inherent and high performance spacer grid shapes, the establishment of mechanical/structural analysis and test technology, and the set-up of basic test facilities for the spacer grid. The main research areas and results are as follows. 1. 18 different spacer grid candidates have been invented and applied for domestic and US patents. Among the candidates 16 are chosen from the patent. 2. Two kinds of spacer grids are finally selected for the advanced LWR fuel after detailed performance tests on the candidates and commercial spacer grids from a mechanical/structural point of view. According to the test results the features of the selected spacer grids are better than those of the commercial spacer grids. 3. Four kinds of basic test facilities are set up and the relevant test technologies are established. 4. Mechanical/structural analysis models and technology for spacer grid performance are developed and the analysis results are compared with the test results to enhance the reliability of the models.

  3. Low cost high performance uncertainty quantification

    KAUST Repository

    Bekas, C.

    2009-01-01

    Uncertainty quantification in risk analysis has become a key application. In this context, computing the diagonal of inverse covariance matrices is of paramount importance. Standard techniques, that employ matrix factorizations, incur a cubic cost which quickly becomes intractable with the current explosion of data sizes. In this work we reduce this complexity to quadratic with the synergy of two algorithms that gracefully complement each other and lead to a radically different approach. First, we turned to stochastic estimation of the diagonal. This allowed us to cast the problem as a linear system with a relatively small number of multiple right hand sides. Second, for this linear system we developed a novel, mixed precision, iterative refinement scheme, which uses iterative solvers instead of matrix factorizations. We demonstrate that the new framework not only achieves the much needed quadratic cost but in addition offers excellent opportunities for scaling at massively parallel environments. We based our implementation on BLAS 3 kernels that ensure very high processor performance. We achieved a peak performance of 730 TFlops on 72 BG/P racks, with a sustained performance 73% of theoretical peak. We stress that the techniques presented in this work are quite general and applicable to several other important applications. Copyright © 2009 ACM.

  4. Energy Efficient Graphene Based High Performance Capacitors.

    Science.gov (United States)

    Bae, Joonwon; Kwon, Oh Seok; Lee, Chang-Soo

    2017-07-10

    Graphene (GRP) is an interesting class of nano-structured electronic materials for various cutting-edge applications. To date, extensive research activities have been performed on the investigation of diverse properties of GRP. The incorporation of this elegant material can be very lucrative in terms of practical applications in energy storage/conversion systems. Among various those systems, high performance electrochemical capacitors (ECs) have become popular due to the recent need for energy efficient and portable devices. Therefore, in this article, the application of GRP for capacitors is described succinctly. In particular, a concise summary on the previous research activities regarding GRP based capacitors is also covered extensively. It was revealed that a lot of secondary materials such as polymers and metal oxides have been introduced to improve the performance. Also, diverse devices have been combined with capacitors for better use. More importantly, recent patents related to the preparation and application of GRP based capacitors are also introduced briefly. This article can provide essential information for future study. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. SISYPHUS: A high performance seismic inversion factory

    Science.gov (United States)

    Gokhberg, Alexey; Simutė, Saulė; Boehm, Christian; Fichtner, Andreas

    2016-04-01

    In the recent years the massively parallel high performance computers became the standard instruments for solving the forward and inverse problems in seismology. The respective software packages dedicated to forward and inverse waveform modelling specially designed for such computers (SPECFEM3D, SES3D) became mature and widely available. These packages achieve significant computational performance and provide researchers with an opportunity to solve problems of bigger size at higher resolution within a shorter time. However, a typical seismic inversion process contains various activities that are beyond the common solver functionality. They include management of information on seismic events and stations, 3D models, observed and synthetic seismograms, pre-processing of the observed signals, computation of misfits and adjoint sources, minimization of misfits, and process workflow management. These activities are time consuming, seldom sufficiently automated, and therefore represent a bottleneck that can substantially offset performance benefits provided by even the most powerful modern supercomputers. Furthermore, a typical system architecture of modern supercomputing platforms is oriented towards the maximum computational performance and provides limited standard facilities for automation of the supporting activities. We present a prototype solution that automates all aspects of the seismic inversion process and is tuned for the modern massively parallel high performance computing systems. We address several major aspects of the solution architecture, which include (1) design of an inversion state database for tracing all relevant aspects of the entire solution process, (2) design of an extensible workflow management framework, (3) integration with wave propagation solvers, (4) integration with optimization packages, (5) computation of misfits and adjoint sources, and (6) process monitoring. The inversion state database represents a hierarchical structure with

  6. A statistical approach to evaluate the performance of cardiac biomarkers in predicting death due to acute myocardial infarction: time-dependent ROC curve

    Science.gov (United States)

    Karaismailoğlu, Eda; Dikmen, Zeliha Günnur; Akbıyık, Filiz; Karaağaoğlu, Ahmet Ergun

    2018-04-30

    Background/aim: Myoglobin, cardiac troponin T, B-type natriuretic peptide (BNP), and creatine kinase isoenzyme MB (CK-MB) are frequently used biomarkers for evaluating risk of patients admitted to an emergency department with chest pain. Recently, time- dependent receiver operating characteristic (ROC) analysis has been used to evaluate the predictive power of biomarkers where disease status can change over time. We aimed to determine the best set of biomarkers that estimate cardiac death during follow-up time. We also obtained optimal cut-off values of these biomarkers, which differentiates between patients with and without risk of death. A web tool was developed to estimate time intervals in risk. Materials and methods: A total of 410 patients admitted to the emergency department with chest pain and shortness of breath were included. Cox regression analysis was used to determine an optimal set of biomarkers that can be used for estimating cardiac death and to combine the significant biomarkers. Time-dependent ROC analysis was performed for evaluating performances of significant biomarkers and a combined biomarker during 240 h. The bootstrap method was used to compare statistical significance and the Youden index was used to determine optimal cut-off values. Results : Myoglobin and BNP were significant by multivariate Cox regression analysis. Areas under the time-dependent ROC curves of myoglobin and BNP were about 0.80 during 240 h, and that of the combined biomarker (myoglobin + BNP) increased to 0.90 during the first 180 h. Conclusion: Although myoglobin is not clinically specific to a cardiac event, in our study both myoglobin and BNP were found to be statistically significant for estimating cardiac death. Using this combined biomarker may increase the power of prediction. Our web tool can be useful for evaluating the risk status of new patients and helping clinicians in making decisions.

  7. Ultra high performance concrete dematerialization study

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-03-01

    Concrete is the most widely used building material in the world and its use is expected to grow. It is well recognized that the production of portland cement results in the release of large amounts of carbon dioxide, a greenhouse gas (GHG). The main challenge facing the industry is to produce concrete in an environmentally sustainable manner. Reclaimed industrial by-proudcts such as fly ash, silica fume and slag can reduce the amount of portland cement needed to make concrete, thereby reducing the amount of GHGs released to the atmosphere. The use of these supplementary cementing materials (SCM) can also enhance the long-term strength and durability of concrete. The intention of the EcoSmart{sup TM} Concrete Project is to develop sustainable concrete through innovation in supply, design and construction. In particular, the project focuses on finding a way to minimize the GHG signature of concrete by maximizing the replacement of portland cement in the concrete mix with SCM while improving the cost, performance and constructability. This paper describes the use of Ductal{sup R} Ultra High Performance Concrete (UHPC) for ramps in a condominium. It examined the relationship between the selection of UHPC and the overall environmental performance, cost, constructability maintenance and operational efficiency as it relates to the EcoSmart Program. The advantages and challenges of using UHPC were outlined. In addition to its very high strength, UHPC has been shown to have very good potential for GHG emission reduction due to the reduced material requirements, reduced transport costs and increased SCM content. refs., tabs., figs.

  8. JT-60U high performance regimes

    International Nuclear Information System (INIS)

    Ishida, S.

    1999-01-01

    High performance regimes of JT-60U plasmas are presented with an emphasis upon the results from the use of a semi-closed pumped divertor with W-shaped geometry. Plasma performance in transient and quasi steady states has been significantly improved in reversed shear and high- βp regimes. The reversed shear regime elevated an equivalent Q DT eq transiently up to 1.25 (n D (0)τ E T i (0)=8.6x10 20 m-3·s·keV) in a reactor-relevant thermonuclear dominant regime. Long sustainment of enhanced confinement with internal transport barriers (ITBs) with a fully non-inductive current drive in a reversed shear discharge was successfully demonstrated with LH wave injection. Performance sustainment has been extended in the high- bp regime with a high triangularity achieving a long sustainment of plasma conditions equivalent to Q DT eq ∼0.16 (n D (0)τ E T i (0)∼1.4x10 20 m -3 ·s·keV) for ∼4.5 s with a large non-inductive current drive fraction of 60-70% of the plasma current. Thermal and particle transport analyses show significant reduction of thermal and particle diffusivities around ITB resulting in a strong Er shear in the ITB region. The W-shaped divertor is effective for He ash exhaust demonstrating steady exhaust capability of τ He */τ E ∼3-10 in support of ITER. Suppression of neutral back flow and chemical sputtering effect have been observed while MARFE onset density is rather decreased. Negative-ion based neutral beam injection (N-NBI) experiments have created a clear H-mode transition. Enhanced ionization cross- section due to multi-step ionization processes was confirmed as theoretically predicted. A current density profile driven by N-NBI is measured in a good agreement with theoretical prediction. N-NBI induced TAE modes characterized as persistent and bursting oscillations have been observed from a low hot beta of h >∼0.1-0.2% without a significant loss of fast ions. (author)

  9. Cardioprotective effect of valsartan in mice with short-term high-salt diet by regulating cardiac aquaporin 1 and angiogenic factor expression.

    Science.gov (United States)

    Jiang, Yong; Wang, Hui-Yan; Zheng, Sheng; Mu, Shang-Qiang; Ma, Meng-Ni; Xie, Xin; Zhang, Yang-Yang; Zhang, Chun-Xue; Cai, Jian-Hui

    2015-01-01

    Hypertension is the most common risk factor for various cardiovascular and cerebrovascular diseases that affects approximately 61 million, or 25% of the population in United States. The dietary salt intake is one of the most important but modifiable factors for hypertension. In the current study, we aim to elucidate the role of aquaporin 1 in high-salt-induced hypertension and cardiac injuries and whether angiotensin II receptor blocker valsartan could ameliorate the effect of high salt on blood pressure. Mice were fed with normal diet, high-salt diet in the presence or absence of valsartan for 4 weeks. The body weight gain, feeding behavior, blood pressure, and cardiac pathology changes were monitored after 4 weeks. The expression of aquaporin 1, vascular endothelial growth factor, transforming growth factor β1, and basic fibroblast growth factor were analyzed using quantitative real-time polymerase chain reaction, Western blot, and immunohistochemical staining. Valsartan partially reversed the effects of high-salt diet on hypertension, cardiac injuries such as fibrosis and inflammatory cell infiltration, and inhibition of aquaporin 1 and angiogenic factors; valsartan alone did not exert such effects. The current data demonstrated that the reduction of cardiac aquaporin 1 and angiogenic factor expression level might be associated with high-salt-induced hypertension and cardiac injuries in mice, which could be ameliorated by angiotensin II receptor blocker treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. High-performance phase-field modeling

    KAUST Repository

    Vignal, Philippe

    2015-04-27

    Many processes in engineering and sciences involve the evolution of interfaces. Among the mathematical frameworks developed to model these types of problems, the phase-field method has emerged as a possible solution. Phase-fields nonetheless lead to complex nonlinear, high-order partial differential equations, whose solution poses mathematical and computational challenges. Guaranteeing some of the physical properties of the equations has lead to the development of efficient algorithms and discretizations capable of recovering said properties by construction [2, 5]. This work builds-up on these ideas, and proposes novel discretization strategies that guarantee numerical energy dissipation for both conserved and non-conserved phase-field models. The temporal discretization is based on a novel method which relies on Taylor series and ensures strong energy stability. It is second-order accurate, and can also be rendered linear to speed-up the solution process [4]. The spatial discretization relies on Isogeometric Analysis, a finite element method that possesses the k-refinement technology and enables the generation of high-order, high-continuity basis functions. These basis functions are well suited to handle the high-order operators present in phase-field models. Two-dimensional and three dimensional results of the Allen-Cahn, Cahn-Hilliard, Swift-Hohenberg and phase-field crystal equation will be presented, which corroborate the theoretical findings, and illustrate the robustness of the method. Results related to more challenging examples, namely the Navier-Stokes Cahn-Hilliard and a diusion-reaction Cahn-Hilliard system, will also be presented. The implementation was done in PetIGA and PetIGA-MF, high-performance Isogeometric Analysis frameworks [1, 3], designed to handle non-linear, time-dependent problems.

  11. High performance visual display for HENP detectors

    International Nuclear Information System (INIS)

    McGuigan, Michael; Smith, Gordon; Spiletic, John; Fine, Valeri; Nevski, Pavel

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactive control, including the ability to slice, search and mark areas of the detector. We incorporate the ability to make a high quality still image of a view of the detector and the ability to generate animations and a fly through of the detector and output these to MPEG or VRML models. We develop data compression hardware and software so that remote interactive visualization will be possible among dispersed collaborators. We obtain real time visual display for events accumulated during simulations

  12. Development of high performance ODS alloys

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Lin [Texas A & M Univ., College Station, TX (United States); Gao, Fei [Univ. of Michigan, Ann Arbor, MI (United States); Garner, Frank [Texas A & M Univ., College Station, TX (United States)

    2018-01-29

    This project aims to capitalize on insights developed from recent high-dose self-ion irradiation experiments in order to develop and test the next generation of optimized ODS alloys needed to meet the nuclear community's need for high strength, radiation-tolerant cladding and core components, especially with enhanced resistance to void swelling. Two of these insights are that ferrite grains swell earlier than tempered martensite grains, and oxide dispersions currently produced only in ferrite grains require a high level of uniformity and stability to be successful. An additional insight is that ODS particle stability is dependent on as-yet unidentified compositional combinations of dispersoid and alloy matrix, such as dispersoids are stable in MA957 to doses greater than 200 dpa but dissolve in MA956 at doses less than 200 dpa. These findings focus attention on candidate next-generation alloys which address these concerns. Collaboration with two Japanese groups provides this project with two sets of first-round candidate alloys that have already undergone extensive development and testing for unirradiated properties, but have not yet been evaluated for their irradiation performance. The first set of candidate alloys are dual phase (ferrite + martensite) ODS alloys with oxide particles uniformly distributed in both ferrite and martensite phases. The second set of candidate alloys are ODS alloys containing non-standard dispersoid compositions with controllable oxide particle sizes, phases and interfaces.

  13. Low-Cost High-Performance MRI

    Science.gov (United States)

    Sarracanie, Mathieu; Lapierre, Cristen D.; Salameh, Najat; Waddington, David E. J.; Witzel, Thomas; Rosen, Matthew S.

    2015-10-01

    Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5-3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site, and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm3 imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (standards for affordable (<$50,000) and robust portable devices.

  14. Differential effects of high-fat and high-carbohydrate isoenergetic meals on cardiac autonomic nervous system activity in lean and obese women.

    Science.gov (United States)

    Tentolouris, N; Tsigos, C; Perea, D; Koukou, E; Kyriaki, D; Kitsou, E; Daskas, S; Daifotis, Z; Makrilakis, K; Raptis, S A; Katsilambros, N

    2003-11-01

    Food ingestion can influence autonomic nervous system activity. This study compares the effects of 2 different isoenergetic meals on sympathetic nervous system (SNS) activity, assessed by heart rate variability (HRV) and plasma norepinephrine (NE) levels, in lean and obese women. Fifteen lean and 15 obese healthy women were examined on 2 occasions: after a carbohydrate (CHO)-rich and after a fat-rich test meal. Measurements of blood pressure, heart rate, resting energy expenditure, plasma glucose, lipids, insulin, leptin, and NE, as well as spectral analysis of the HRV, were performed at baseline and every 1 hour for 3 hours after meals. At baseline, obese women had higher SNS activity than lean controls (higher values of low-to-high frequency ratio [LF/HF], 1.52 +/- 0.31 v 0.78 +/- 0.13, P=.04; and plasma NE levels, 405.6 +/- 197.9 v 240.5 +/- 95.8 pg/mL, Pmeal a greater increase in LF/HF and in plasma NE levels was observed in lean, compared to obese women (1.21 +/- 0.6 v 0.32 +/- 0.06, P=.04; and 102.9 +/- 35.4 v 38.7 +/- 12.3 pg/mL, P=.01, respectively), while no differences were observed after the fat-rich meal. Meal-induced thermogenesis was higher after the CHO-rich as compared to the fat-rich meal and was comparable between lean and obese women. Changes in HRV were not associated with the thermogenic response to the test meals. In conclusion, consumption of a CHO-rich meal causes greater cardiac SNS activation in lean than in obese women, while fat ingestion does not result in any appreciable change in either group. SNS activation does not appear to influence the thermic effect of the food in either lean or obese women.

  15. High Performance Computing in Science and Engineering '15 : Transactions of the High Performance Computing Center

    CERN Document Server

    Kröner, Dietmar; Resch, Michael

    2016-01-01

    This book presents the state-of-the-art in supercomputer simulation. It includes the latest findings from leading researchers using systems from the High Performance Computing Center Stuttgart (HLRS) in 2015. The reports cover all fields of computational science and engineering ranging from CFD to computational physics and from chemistry to computer science with a special emphasis on industrially relevant applications. Presenting findings of one of Europe’s leading systems, this volume covers a wide variety of applications that deliver a high level of sustained performance. The book covers the main methods in high-performance computing. Its outstanding results in achieving the best performance for production codes are of particular interest for both scientists and engineers. The book comes with a wealth of color illustrations and tables of results.

  16. High Performance Computing in Science and Engineering '17 : Transactions of the High Performance Computing Center

    CERN Document Server

    Kröner, Dietmar; Resch, Michael; HLRS 2017

    2018-01-01

    This book presents the state-of-the-art in supercomputer simulation. It includes the latest findings from leading researchers using systems from the High Performance Computing Center Stuttgart (HLRS) in 2017. The reports cover all fields of computational science and engineering ranging from CFD to computational physics and from chemistry to computer science with a special emphasis on industrially relevant applications. Presenting findings of one of Europe’s leading systems, this volume covers a wide variety of applications that deliver a high level of sustained performance.The book covers the main methods in high-performance computing. Its outstanding results in achieving the best performance for production codes are of particular interest for both scientists and engineers. The book comes with a wealth of color illustrations and tables of results.

  17. Thermal interface pastes nanostructured for high performance

    Science.gov (United States)

    Lin, Chuangang

    Thermal interface materials in the form of pastes are needed to improve thermal contacts, such as that between a microprocessor and a heat sink of a computer. High-performance and low-cost thermal pastes have been developed in this dissertation by using polyol esters as the vehicle and various nanoscale solid components. The proportion of a solid component needs to be optimized, as an excessive amount degrades the performance, due to the increase in the bond line thickness. The optimum solid volume fraction tends to be lower when the mating surfaces are smoother, and higher when the thermal conductivity is higher. Both a low bond line thickness and a high thermal conductivity help the performance. When the surfaces are smooth, a low bond line thickness can be even more important than a high thermal conductivity, as shown by the outstanding performance of the nanoclay paste of low thermal conductivity in the smooth case (0.009 mum), with the bond line thickness less than 1 mum, as enabled by low storage modulus G', low loss modulus G" and high tan delta. However, for rough surfaces, the thermal conductivity is important. The rheology affects the bond line thickness, but it does not correlate well with the performance. This study found that the structure of carbon black is an important parameter that governs the effectiveness of a carbon black for use in a thermal paste. By using a carbon black with a lower structure (i.e., a lower DBP value), a thermal paste that is more effective than the previously reported carbon black paste was obtained. Graphite nanoplatelet (GNP) was found to be comparable in effectiveness to carbon black (CB) pastes for rough surfaces, but it is less effective for smooth surfaces. At the same filler volume fraction, GNP gives higher thermal conductivity than carbon black paste. At the same pressure, GNP gives higher bond line thickness than CB (Tokai or Cabot). The effectiveness of GNP is limited, due to the high bond line thickness. A

  18. High performance liquid chromatography in pharmaceutical analyses

    Directory of Open Access Journals (Sweden)

    Branko Nikolin

    2004-05-01

    Full Text Available In testing the pre-sale procedure the marketing of drugs and their control in the last ten years, high performance liquid chromatographyreplaced numerous spectroscopic methods and gas chromatography in the quantitative and qualitative analysis. In the first period of HPLC application it was thought that it would become a complementary method of gas chromatography, however, today it has nearly completely replaced gas chromatography in pharmaceutical analysis. The application of the liquid mobile phase with the possibility of transformation of mobilized polarity during chromatography and all other modifications of mobile phase depending upon the characteristics of substance which are being tested, is a great advantage in the process of separation in comparison to other methods. The greater choice of stationary phase is the next factor which enables realization of good separation. The separation line is connected to specific and sensitive detector systems, spectrafluorimeter, diode detector, electrochemical detector as other hyphernated systems HPLC-MS and HPLC-NMR, are the basic elements on which is based such wide and effective application of the HPLC method. The purpose high performance liquid chromatography(HPLC analysis of any drugs is to confirm the identity of a drug and provide quantitative results and also to monitor the progress of the therapy of a disease.1 Measuring presented on the Fig. 1. is chromatogram obtained for the plasma of depressed patients 12 h before oral administration of dexamethasone. It may also be used to further our understanding of the normal and disease process in the human body trough biomedical and therapeutically research during investigation before of the drugs registration. The analyses of drugs and metabolites in biological fluids, particularly plasma, serum or urine is one of the most demanding but one of the most common uses of high performance of liquid chromatography. Blood, plasma or

  19. Combining high productivity with high performance on commodity hardware

    DEFF Research Database (Denmark)

    Skovhede, Kenneth

    -like compiler for translating CIL bytecode on the CELL-BE. I then introduce a bytecode converter that transforms simple loops in Java bytecode to GPGPU capable code. I then introduce the numeric library for the Common Intermediate Language, NumCIL. I can then utilizing the vector programming model from Num......CIL and map this to the Bohrium framework. The result is a complete system that gives the user a choice of high-level languages with no explicit parallelism, yet seamlessly performs efficient execution on a number of hardware setups....

  20. Integrating advanced facades into high performance buildings

    International Nuclear Information System (INIS)

    Selkowitz, Stephen E.

    2001-01-01

    Glass is a remarkable material but its functionality is significantly enhanced when it is processed or altered to provide added intrinsic capabilities. The overall performance of glass elements in a building can be further enhanced when they are designed to be part of a complete facade system. Finally the facade system delivers the greatest performance to the building owner and occupants when it becomes an essential element of a fully integrated building design. This presentation examines the growing interest in incorporating advanced glazing elements into more comprehensive facade and building systems in a manner that increases comfort, productivity and amenity for occupants, reduces operating costs for building owners, and contributes to improving the health of the planet by reducing overall energy use and negative environmental impacts. We explore the role of glazing systems in dynamic and responsive facades that provide the following functionality: Enhanced sun protection and cooling load control while improving thermal comfort and providing most of the light needed with daylighting; Enhanced air quality and reduced cooling loads using natural ventilation schemes employing the facade as an active air control element; Reduced operating costs by minimizing lighting, cooling and heating energy use by optimizing the daylighting-thermal tradeoffs; Net positive contributions to the energy balance of the building using integrated photovoltaic systems; Improved indoor environments leading to enhanced occupant health, comfort and performance. In addressing these issues facade system solutions must, of course, respect the constraints of latitude, location, solar orientation, acoustics, earthquake and fire safety, etc. Since climate and occupant needs are dynamic variables, in a high performance building the facade solution have the capacity to respond and adapt to these variable exterior conditions and to changing occupant needs. This responsive performance capability

  1. The need for high performance breeder reactors

    International Nuclear Information System (INIS)

    Vaughan, R.D.; Chermanne, J.

    1977-01-01

    It can be easily demonstrated, on the basis of realistic estimates of continued high oil costs, that an increasing portion of the growth in energy demand must be supplied by nuclear power and that this one might account for 20% of all the energy production by the end of the century. Such assumptions lead very quickly to the conclusion that the discovery, extraction and processing of the uranium will not be able to follow the demand; the bottleneck will essentially be related to the rate at which the ore can be discovered and extracted, and not to the existing quantities nor their grade. Figures as high as 150.000 T/annum and more would be quickly reached, and it is necessary to wonder already now if enough capital can be attracted to meet these requirements. There is only one solution to this problem: improve the conversion ratio of the nuclear system and quickly reach the breeding; this would lead to the reduction of the natural uranium consumption by a factor of about 50. However, this condition is not sufficient; the commercial breeder must have a breeding gain as high as possible because the Pu out-of-pile time and the Pu losses in the cycle could lead to an unacceptable doubling time for the system, if the breeding gain is too low. That is the reason why it is vital to develop high performance breeder reactors. The present paper indicates how the Gas-cooled Breeder Reactor [GBR] can meet the problems mentioned above, on the basis of recent and realistic studies. It briefly describes the present status of GBR development, from the predecessors in the gas cooled reactor line, particularly the AGR. It shows how the GBR fuel takes mostly profit from the LMFBR fuel irradiation experience. It compares the GBR performance on a consistent basis with that of the LMFBR. The GBR capital and fuel cycle costs are compared with those of thermal and fast reactors respectively. The conclusion is, based on a cost-benefit study, that the GBR must be quickly developed in order

  2. High performance nano-composite technology development

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Whung Whoe; Rhee, C. K.; Kim, S. J.; Park, S. D. [KAERI, Taejon (Korea, Republic of); Kim, E. K.; Jung, S. Y.; Ryu, H. J. [KRICT, Taejon (Korea, Republic of); Hwang, S. S.; Kim, J. K.; Hong, S. M. [KIST, Taejon (Korea, Republic of); Chea, Y. B. [KIGAM, Taejon (Korea, Republic of); Choi, C. H.; Kim, S. D. [ATS, Taejon (Korea, Republic of); Cho, B. G.; Lee, S. H. [HGREC, Taejon (Korea, Republic of)

    1999-06-15

    The trend of new material development are being to carried out not only high performance but also environmental attraction. Especially nano composite material which enhances the functional properties of components, extending the component life resulting to reduced the wastes and environmental contamination, has a great effect on various industrial area. The application of nano composite, depends on the polymer matrix and filler materials, has various application from semiconductor to medical field. In spite of nano composite merits, nano composite study are confined to a few special materials as a lab, scale because a few technical difficulties are still on hold. Therefore, the purpose of this study establishes the systematical planning to carried out the next generation projects on order to compete with other countries and overcome the protective policy of advanced countries with grasping over sea's development trends and our present status. (author).

  3. How to create high-performing teams.

    Science.gov (United States)

    Lam, Samuel M

    2010-02-01

    This article is intended to discuss inspirational aspects on how to lead a high-performance team. Cogent topics discussed include how to hire staff through methods of "topgrading" with reference to Geoff Smart and "getting the right people on the bus" referencing Jim Collins' work. In addition, once the staff is hired, this article covers how to separate the "eagles from the ducks" and how to inspire one's staff by creating the right culture with suggestions for further reading by Don Miguel Ruiz (The four agreements) and John Maxwell (21 Irrefutable laws of leadership). In addition, Simon Sinek's concept of "Start with Why" is elaborated to help a leader know what the core element should be with any superior culture. Thieme Medical Publishers.

  4. High performance nano-composite technology development

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Whung Whoe; Rhee, C. K.; Kim, S. J.; Park, S. D. [KAERI, Taejon (Korea, Republic of); Kim, E. K.; Jung, S. Y.; Ryu, H. J. [KRICT, Taejon (Korea, Republic of); Hwang, S. S.; Kim, J. K.; Hong, S. M. [KIST, Taejon (Korea, Republic of); Chea, Y. B. [KIGAM, Taejon (Korea, Republic of); Choi, C. H.; Kim, S. D. [ATS, Taejon (Korea, Republic of); Cho, B. G.; Lee, S. H. [HGREC, Taejon (Korea, Republic of)

    1999-06-15

    The trend of new material development are being to carried out not only high performance but also environmental attraction. Especially nano composite material which enhances the functional properties of components, extending the component life resulting to reduced the wastes and environmental contamination, has a great effect on various industrial area. The application of nano composite, depends on the polymer matrix and filler materials, has various application from semiconductor to medical field. In spite of nano composite merits, nano composite study are confined to a few special materials as a lab, scale because a few technical difficulties are still on hold. Therefore, the purpose of this study establishes the systematical planning to carried out the next generation projects on order to compete with other countries and overcome the protective policy of advanced countries with grasping over sea's development trends and our present status. (author).

  5. High performance nano-composite technology development

    International Nuclear Information System (INIS)

    Kim, Whung Whoe; Rhee, C. K.; Kim, S. J.; Park, S. D.; Kim, E. K.; Jung, S. Y.; Ryu, H. J.; Hwang, S. S.; Kim, J. K.; Hong, S. M.; Chea, Y. B.; Choi, C. H.; Kim, S. D.; Cho, B. G.; Lee, S. H.

    1999-06-01

    The trend of new material development are being to carried out not only high performance but also environmental attraction. Especially nano composite material which enhances the functional properties of components, extending the component life resulting to reduced the wastes and environmental contamination, has a great effect on various industrial area. The application of nano composite, depends on the polymer matrix and filler materials, has various application from semiconductor to medical field. In spite of nano composite merits, nano composite study are confined to a few special materials as a lab, scale because a few technical difficulties are still on hold. Therefore, the purpose of this study establishes the systematical planning to carried out the next generation projects on order to compete with other countries and overcome the protective policy of advanced countries with grasping over sea's development trends and our present status. (author).

  6. High Performance with Prescriptive Optimization and Debugging

    DEFF Research Database (Denmark)

    Jensen, Nicklas Bo

    parallelization and automatic vectorization is attractive as it transparently optimizes programs. The thesis contributes an improved dependence analysis for explicitly parallel programs. These improvements lead to more loops being vectorized, on average we achieve a speedup of 1.46 over the existing dependence...... analysis and vectorizer in GCC. Automatic optimizations often fail for theoretical and practical reasons. When they fail we argue that a hybrid approach can be effective. Using compiler feedback, we propose to use the programmer’s intuition and insight to achieve high performance. Compiler feedback...... enlightens the programmer why a given optimization was not applied, and suggest how to change the source code to make it more amenable to optimizations. We show how this can yield significant speedups and achieve 2.4 faster execution on a real industrial use case. To aid in parallel debugging we propose...

  7. A High Fat Diet During Pregnancy and Lactation Induces Cardiac and Renal Abnormalities in GLUT4 +/- Male Mice

    Directory of Open Access Journals (Sweden)

    Michael Kruse

    2017-07-01

    Full Text Available Background/Aims: Altered nutrients during the in utero (IU and/or lactation (L period predispose offspring to cardio-renal diseases in adulthood. This study investigates the effect of a high fat diet (HFD fed to female mice during IU/L on gene expression patterns associated with heart and kidney failure and hypertension in male offspring. Methods: Female wild type (WT mice were fed either a HFD or control chow (C prior to mating with males with a genetic heterozygous deletion of GLUT4 (G4+/-, a model of peripheral insulin resistance and hypertension and throughout IU/L. After weaning male offspring were placed on a standard rodent chow until 24 weeks of age. Results: All offspring exposed to a maternal HFD showed increased heart and kidney weight and reduced cardiac insulin responsiveness. G4+/- offspring on a HFD displayed early hypertension associated with increased renal gene expression of renin and the AT1- receptors compared to G4+/- on a C diet. This group showed decreased cardiac expression of key genes involved in fatty acid oxidation compared to WT on a C diet. Conclusions: These results indicate an interaction between a HFD diet and genotype during early life development that can enhance susceptibility to cardio-renal diseases later in life.

  8. PGC-1/Spargel Counteracts High-Fat-Diet-Induced Obesity and Cardiac Lipotoxicity Downstream of TOR and Brummer ATGL Lipase

    Directory of Open Access Journals (Sweden)

    Soda Balla Diop

    2015-03-01

    Full Text Available Obesity and metabolic syndrome are associated with an increased risk for lipotoxic cardiomyopathy, which is strongly correlated with excessive accumulation of lipids in the heart. Obesity- and type-2-diabetes-related disorders have been linked to altered expression of the transcriptional cofactor PGC-1α, which regulates the expression of genes involved in energy metabolism. Using Drosophila, we identify PGC-1/spargel (PGC-1/srl as a key antagonist of high-fat diet (HFD-induced lipotoxic cardiomyopathy. We find that HFD-induced lipid accumulation and cardiac dysfunction are mimicked by reduced PGC-1/srl function and reversed by PGC-1/srl overexpression. Moreover, HFD feeding lowers PGC-1/srl expression by elevating TOR signaling and inhibiting expression of the Drosophila adipocyte triglyceride lipase (ATGL (Brummer, both of which function as upstream modulators of PGC-1/srl. The lipogenic transcription factor SREBP also contributes to HFD-induced cardiac lipotoxicity, likely in parallel with PGC-1/srl. These results suggest a regulatory network of key metabolic genes that modulates lipotoxic heart dysfunction.

  9. High Intensity Interval and Endurance Training Have Opposing Effects on Markers of Heart Failure and Cardiac Remodeling in Hypertensive Rats

    Science.gov (United States)

    Holloway, Tanya M.; Bloemberg, Darin; da Silva, Mayne L.; Simpson, Jeremy A.; Quadrilatero, Joe; Spriet, Lawrence L.

    2015-01-01

    There has been re-emerging interest and significant work dedicated to investigating the metabolic effects of high intensity interval training (HIIT) in recent years. HIIT is considered to be a time efficient alternative to classic endurance training (ET) that elicits similar metabolic responses in skeletal muscle. However, there is a lack of information on the impact of HIIT on cardiac muscle in disease. Therefore, we determined the efficacy of ET and HIIT to alter cardiac muscle characteristics involved in the development of diastolic dysfunction, such as ventricular hypertrophy, fibrosis and angiogenesis, in a well-established rodent model of hypertension-induced heart failure before the development of overt heart failure. ET decreased left ventricle fibrosis by ~40% (P HIIT did not decrease existing fibrosis, and HIIT animals displayed a 20% increase in left ventricular mass (PHIIT also increased brain natriuretic peptide by 50% (PHIIT promoted a pathological adaptation in the left ventricle in the presence of hypertension, highlighting the need for further research on the widespread effects of HIIT in the presence of disease. PMID:25803693

  10. Optimizing High Performance Self Compacting Concrete

    Directory of Open Access Journals (Sweden)

    Raymond A Yonathan

    2017-01-01

    Full Text Available This paper’s objectives are to learn the effect of glass powder, silica fume, Polycarboxylate Ether, and gravel to optimizing composition of each factor in making High Performance SCC. Taguchi method is proposed in this paper as best solution to minimize specimen variable which is more than 80 variations. Taguchi data analysis method is applied to provide composition, optimizing, and the effect of contributing materials for nine variable of specimens. Concrete’s workability was analyzed using Slump flow test, V-funnel test, and L-box test. Compressive and porosity test were performed for the hardened state. With a dimension of 100×200 mm the cylindrical specimens were cast for compressive test with the age of 3, 7, 14, 21, 28 days. Porosity test was conducted at 28 days. It is revealed that silica fume contributes greatly to slump flow and porosity. Coarse aggregate shows the greatest contributing factor to L-box and compressive test. However, all factors show unclear result to V-funnel test.

  11. High-precision γ -ray spectroscopy of the cardiac PET imaging isotope 82Rb and its impact on dosimetry

    Science.gov (United States)

    Nino, M. N.; McCutchan, E. A.; Smith, S. V.; Lister, C. J.; Greene, J. P.; Carpenter, M. P.; Muench, L.; Sonzogni, A. A.; Zhu, S.

    2016-02-01

    82Rb is a positron-emitting isotope used in cardiac positron emission tomography (PET) imaging which has been reported to deliver a significantly lower effective radiation dose than analogous imaging isotopes like 201Tl and 99 mTc sestamibi. High-quality β -decay data are essential to accurately appraise the total dose received by the patients. A source of 82Sr was produced at the Brookhaven Linac Isotope Producer (BLIP), transported to Argonne National Laboratory, and studied with the Gammasphere facility. Significant revisions have been made to the level scheme of 82Kr including 12 new levels, 50 new γ -ray transitions, and the determination of many new spin assignments through angular correlations. These new high-quality data allow a precise reappraisal of the β -decay strength function and thus the consequent dose received by patients.

  12. Performance of a remote interrogation system for the in-hospital evaluation of cardiac implantable electronic devices.

    Science.gov (United States)

    Mittal, Suneet; Younge, Kevin; King-Ellison, Kelly; Hammill, Eric; Stein, Kenneth

    2016-08-01

    Patients with a cardiac implantable electronic device (CIED) often need device interrogation in an in-hospital environment. A diagnosis-only, remote interrogation device and process for CIED interrogation was developed to address this situation. Here, we describe our initial clinical experience with this system. The LATITUDE Consult Communicator is a stand-alone interrogation-only device used to read the patient's implanted CIED. Once retrieved, the data are securely transmitted via an analog phone line to a central server. The clinician can request a review of the transmitted data at any time. Following FDA approval, we determined the usage and performance of the system. Communicators (n = 53) were installed in 42 hospital facilities. The most common location was in the emergency department (n = 32, 60 %). There were 509 discreet transmissions, which were categorized as follows: no arrhythmia episodes in the past 72 h and no out of range measurements (n = 174, 34 %); arrhythmia episodes in past 72 h but no out of range measurements (n = 170, 33 %); and further review recommended (n = 130, 26 %). (In 35 [7 %] instances, interrogation without analysis was requested.) The further review interrogations were then sub-divided into those of a non-urgent and urgent nature. Overall, only 53 (10 %) of the 509 transmissions were classified as urgent. Clinicians had access to full technical consultation in ≤15 min in 89 % of instances. Our data demonstrate the feasibility of a new diagnosis-only, remote interrogation device and remote evaluation process for the interrogation of CIEDs in an in-hospital environment.

  13. Immediate changes in estimated cardiac output and vascular resistance after 60Co exposure in monkeys: implication for performance decrement

    International Nuclear Information System (INIS)

    Bruner, A.

    1977-01-01

    Aortic blood flow velocity, blood pressure, and heart rate were recorded in 12 unanesthetized, nonperforming monkeys during exposure to 1000 rad 60 Co at 129--164 rad/min. The first postradiation changes were seen within 3--4 min of the exposure's start and included tachycardia, a transient hypotension secondary to a loss in peripheral resistance, and a brief increase followed by a decrease to subnormal levels in cardiac output. The lowest cardiac output occurred between 10 and 20 min postexposure while blood pressure and peripheral resistance were recovering. It was proposed that the concurrent combination of low cardiac output, low blood pressure, and supranormal peripheral resistance might sufficiently attenuate cerebral perfusion temporarily to account for the transient behavioral decrements often seen during this time. Histamine release was postulated as responsible for this vascular shock syndrome

  14. High Performance Circularly Polarized Microstrip Antenna

    Science.gov (United States)

    Bondyopadhyay, Probir K. (Inventor)

    1997-01-01

    A microstrip antenna for radiating circularly polarized electromagnetic waves comprising a cluster array of at least four microstrip radiator elements, each of which is provided with dual orthogonal coplanar feeds in phase quadrature relation achieved by connection to an asymmetric T-junction power divider impedance notched at resonance. The dual fed circularly polarized reference element is positioned with its axis at a 45 deg angle with respect to the unit cell axis. The other three dual fed elements in the unit cell are positioned and fed with a coplanar feed structure with sequential rotation and phasing to enhance the axial ratio and impedance matching performance over a wide bandwidth. The centers of the radiator elements are disposed at the corners of a square with each side of a length d in the range of 0.7 to 0.9 times the free space wavelength of the antenna radiation and the radiator elements reside in a square unit cell area of sides equal to 2d and thereby permit the array to be used as a phased array antenna for electronic scanning and is realizable in a high temperature superconducting thin film material for high efficiency.

  15. NCI's Transdisciplinary High Performance Scientific Data Platform

    Science.gov (United States)

    Evans, Ben; Antony, Joseph; Bastrakova, Irina; Car, Nicholas; Cox, Simon; Druken, Kelsey; Evans, Bradley; Fraser, Ryan; Ip, Alex; Kemp, Carina; King, Edward; Minchin, Stuart; Larraondo, Pablo; Pugh, Tim; Richards, Clare; Santana, Fabiana; Smillie, Jon; Trenham, Claire; Wang, Jingbo; Wyborn, Lesley

    2016-04-01

    The Australian National Computational Infrastructure (NCI) manages Earth Systems data collections sourced from several domains and organisations onto a single High Performance Data (HPD) Node to further Australia's national priority research and innovation agenda. The NCI HPD Node has rapidly established its value, currently managing over 10 PBytes of datasets from collections that span a wide range of disciplines including climate, weather, environment, geoscience, geophysics, water resources and social sciences. Importantly, in order to facilitate broad user uptake, maximise reuse and enable transdisciplinary access through software and standardised interfaces, the datasets, associated information systems and processes have been incorporated into the design and operation of a unified platform that NCI has called, the National Environmental Research Data Interoperability Platform (NERDIP). The key goal of the NERDIP is to regularise data access so that it is easily discoverable, interoperable for different domains and enabled for high performance methods. It adopts and implements international standards and data conventions, and promotes scientific integrity within a high performance computing and data analysis environment. NCI has established a rich and flexible computing environment to access to this data, through the NCI supercomputer; a private cloud that supports both domain focused virtual laboratories and in-common interactive analysis interfaces; as well as remotely through scalable data services. Data collections of this importance must be managed with careful consideration of both their current use and the needs of the end-communities, as well as its future potential use, such as transitioning to more advanced software and improved methods. It is therefore critical that the data platform is both well-managed and trusted for stable production use (including transparency and reproducibility), agile enough to incorporate new technological advances and

  16. High Power Flex-Propellant Arcjet Performance

    Science.gov (United States)

    Litchford, Ron J.

    2011-01-01

    implied nearly frozen flow in the nozzle and yielded performance ranges of 800-1100 sec for hydrogen and 400-600 sec for ammonia. Inferred thrust-to-power ratios were in the range of 30-10 lbf/MWe for hydrogen and 60-20 lbf/MWe for ammonia. Successful completion of this test series represents a fundamental milestone in the progression of high power arcjet technology, and it is hoped that the results may serve as a reliable touchstone for the future development of MW-class regeneratively-cooled flex-propellant plasma rockets.

  17. Silicon Photomultiplier Performance in High ELectric Field

    Science.gov (United States)

    Montoya, J.; Morad, J.

    2016-12-01

    Roughly 27% of the universe is thought to be composed of dark matter. The Large Underground Xenon (LUX) relies on the emission of light from xenon atoms after a collision with a dark matter particle. After a particle interaction in the detector, two things can happen: the xenon will emit light and charge. The charge (electrons), in the liquid xenon needs to be pulled into the gas section so that it can interact with gas and emit light. This allows LUX to convert a single electron into many photons. This is done by applying a high voltage across the liquid and gas regions, effectively ripping electrons out of the liquid xenon and into the gas. The current device used to detect photons is the photomultiplier tube (PMT). These devices are large and costly. In recent years, a new technology that is capable of detecting single photons has emerged, the silicon photomultiplier (SiPM). These devices are cheaper and smaller than PMTs. Their performance in a high electric fields, such as those found in LUX, are unknown. It is possible that a large electric field could introduce noise on the SiPM signal, drowning the single photon detection capability. My hypothesis is that SiPMs will not observe a significant increase is noise at an electric field of roughly 10kV/cm (an electric field within the range used in detectors like LUX). I plan to test this hypothesis by first rotating the SiPMs with no applied electric field between two metal plates roughly 2 cm apart, providing a control data set. Then using the same angles test the dark counts with the constant electric field applied. Possibly the most important aspect of LUX, is the photon detector because it's what detects the signals. Dark matter is detected in the experiment by looking at the ratio of photons to electrons emitted for a given interaction in the detector. Interactions with a low electron to photon ratio are more like to be dark matter events than those with a high electron to photon ratio. The ability to

  18. The Role of Performance Management in the High Performance Organisation

    NARCIS (Netherlands)

    de Waal, André A.; van der Heijden, Beatrice I.J.M.

    2014-01-01

    The allegiance of partnering organisations and their employees to an Extended Enterprise performance is its proverbial sword of Damocles. Literature on Extended Enterprises focuses on collaboration, inter-organizational integration and learning to avoid diminishing or missing allegiance becoming an

  19. HIV-infected Children in Malawi Have Decreased Performance on the 6-minute Walk Test With Preserved Cardiac Mechanics Regardless of Antiretroviral Treatment Status.

    Science.gov (United States)

    Sims Sanyahumbi, Amy E; Hosseinipour, Mina C; Guffey, Danielle; Hoffman, Irving; Kazembe, Peter N; McCrary, Madeline; Minard, Charles G; van der Horst, Charles; Sable, Craig A

    2017-07-01

    The aims of this study were to 1) determine if cardiac disease can be detected in HIV-infected children by strain imaging and 2) to evaluate differences in exercise performance between HIV-infected children on antiretroviral therapy (ART) and HIV-infected children not yet on ART and in HIV-uninfected children by 6-minute walk tests (6MWTs). This cross-sectional study evaluated cardiac function by echocardiogram and exercise performance by 6MWT in HIV-infected and HIV-uninfected children 4-18 years of age in Lilongwe, Malawi. Analyses compared HIV uninfected, HIV infected not yet on ART, and HIV infected on ART. Comparisons used χ test, t test, analysis of variance and multiple linear regression. No differences were found in ejection fraction, shortening fraction or strain in 73 children not yet on ART, 149 on ART and 77 HIV-uninfected controls. As viral load increased, children had worse circumferential strain. In addition, children receiving ART had better circumferential strain than those not yet on ART. Increased CD4 percentage was associated with better longitudinal strain and farther 6MWT distance. As longitudinal strain worsened, the 6MWT distance decreased. HIV-infected children not yet on ART walked a mean of 25.8 m less than HIV-uninfected children, and HIV-infected children on ART walked 25.9 m less (P = 0.015 comparing 3 groups). HIV-uninfected children performed better on the 6MWT than HIV-infected children. Lower viral load, being on ART, and higher CD4 percentage were associated with better strain measures. Better longitudinal strain was associated with a farther 6MWT distance. Overall, ejection fraction, shortening fraction and strain measures between groups were similar, so cardiac strain did not detect cardiac dysfunction in this young population.

  20. Evaluating performance of high efficiency mist eliminators

    Energy Technology Data Exchange (ETDEWEB)

    Waggoner, Charles A.; Parsons, Michael S.; Giffin, Paxton K. [Mississippi State University, Institute for Clean Energy Technology, 205 Research Blvd, Starkville, MS (United States)

    2013-07-01

    Processing liquid wastes frequently generates off gas streams with high humidity and liquid aerosols. Droplet laden air streams can be produced from tank mixing or sparging and processes such as reforming or evaporative volume reduction. Unfortunately these wet air streams represent a genuine threat to HEPA filters. High efficiency mist eliminators (HEME) are one option for removal of liquid aerosols with high dissolved or suspended solids content. HEMEs have been used extensively in industrial applications, however they have not seen widespread use in the nuclear industry. Filtering efficiency data along with loading curves are not readily available for these units and data that exist are not easily translated to operational parameters in liquid waste treatment plants. A specialized test stand has been developed to evaluate the performance of HEME elements under use conditions of a US DOE facility. HEME elements were tested at three volumetric flow rates using aerosols produced from an iron-rich waste surrogate. The challenge aerosol included submicron particles produced from Laskin nozzles and super micron particles produced from a hollow cone spray nozzle. Test conditions included ambient temperature and relative humidities greater than 95%. Data collected during testing HEME elements from three different manufacturers included volumetric flow rate, differential temperature across the filter housing, downstream relative humidity, and differential pressure (dP) across the filter element. Filter challenge was discontinued at three intermediate dPs and the filter to allow determining filter efficiency using dioctyl phthalate and then with dry surrogate aerosols. Filtering efficiencies of the clean HEME, the clean HEME loaded with water, and the HEME at maximum dP were also collected using the two test aerosols. Results of the testing included differential pressure vs. time loading curves for the nine elements tested along with the mass of moisture and solid

  1. Electrocardiography-triggered high-resolution CT for reducing cardiac motion artifact. Evaluation of the extent of ground-glass attenuation in patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Nishiura, Motoko; Johkoh, Takeshi; Yamamoto, Shuji

    2007-01-01

    The aim of this study was to evaluate the decreasing of cardiac motion artifact and whether the extent of ground-glass attenuation of idiopathic pulmonary fibrosis (IPF) was accurately assessed by electrocardiography (ECG)-triggered high-resolution computed tomography (HRCT) by 0.5-s/rotation multidetector-row CT (MDCT). ECG-triggered HRCT were scanned at the end-diastolic phase by a MDCT scanner with the following scan parameters; axial four-slice mode, 0.5 mm collimation, 0.5-s/rotation, 120 kVp, 200 mA/rotation, high-frequency algorithm, and half reconstruction. In 42 patients with IPF, both conventional HRCT (ECG gating (-), full reconstruction) and ECG-triggered HRCT were performed at the same levels (10-mm intervals) with the above scan parameters. The correlation between percent diffusion of carbon monoxide of the lung (%DLCO) and the mean extent of ground-glass attenuation on both conventional HRCT and ECG-triggered HRCT was evaluated with the Spearman rank correlation coefficient test. The correlation between %DLCO and the mean extent of ground-glass attenuation on ECG-triggered HRCT (observer A: r=-0.790, P<0.0001; observer B: r=-0.710, P<0.0001) was superior to that on conventional HRCT (observer A: r=-0.395, P<0.05; observer B: r=-0.577, P=0.002) for both observers. ECG-triggered HRCT by 0.5 s/rotation MDCT can reduce the cardiac motion artifact and is useful for evaluating the extent of ground-glass attenuation of IPF. (author)

  2. Effects of changes in water salinity upon exercise and cardiac performance in the European seabass ( Dicentrarchus labrax )

    DEFF Research Database (Denmark)

    Chatelier, A.; McKenzie, David; Claireaux, G.

    2005-01-01

    of a plateau as the fish approached a U-crit of 2.25 +/- 0.08 bodylengths s(-1). Increases in Q during exercise were almost exclusively due to increased heart rate rather than ventricular stroke volume. There were no significant effects of the changes in salinity upon M-O2 during exercise, U-crit or cardiac...

  3. An integrated high performance Fastbus slave interface

    International Nuclear Information System (INIS)

    Christiansen, J.; Ljuslin, C.

    1993-01-01

    A high performance CMOS Fastbus slave interface ASIC (Application Specific Integrated Circuit) supporting all addressing and data transfer modes defined in the IEEE 960 - 1986 standard is presented. The FAstbus Slave Integrated Circuit (FASIC) is an interface between the asynchronous Fastbus and a clock synchronous processor/memory bus. It can work stand-alone or together with a 32 bit microprocessor. The FASIC is a programmable device enabling its direct use in many different applications. A set of programmable address mapping windows can map Fastbus addresses to convenient memory addresses and at the same time act as address decoding logic. Data rates of 100 MBytes/sec to Fastbus can be obtained using an internal FIFO in the FASIC to buffer data between the two buses during block transfers. Message passing from Fastbus to a microprocessor on the slave module is supported. A compact (70 mm x 170 mm) Fastbus slave piggy back sub-card interface including level conversion between ECL and TTL signal levels has been implemented using surface mount components and the 208 pin FASIC chip

  4. High Performance Graphene Oxide Based Rubber Composites

    Science.gov (United States)

    Mao, Yingyan; Wen, Shipeng; Chen, Yulong; Zhang, Fazhong; Panine, Pierre; Chan, Tung W.; Zhang, Liqun; Liang, Yongri; Liu, Li

    2013-01-01

    In this paper, graphene oxide/styrene-butadiene rubber (GO/SBR) composites with complete exfoliation of GO sheets were prepared by aqueous-phase mixing of GO colloid with SBR latex and a small loading of butadiene-styrene-vinyl-pyridine rubber (VPR) latex, followed by their co-coagulation. During co-coagulation, VPR not only plays a key role in the prevention of aggregation of GO sheets but also acts as an interface-bridge between GO and SBR. The results demonstrated that the mechanical properties of the GO/SBR composite with 2.0 vol.% GO is comparable with those of the SBR composite reinforced with 13.1 vol.% of carbon black (CB), with a low mass density and a good gas barrier ability to boot. The present work also showed that GO-silica/SBR composite exhibited outstanding wear resistance and low-rolling resistance which make GO-silica/SBR very competitive for the green tire application, opening up enormous opportunities to prepare high performance rubber composites for future engineering applications. PMID:23974435

  5. Initial rheological description of high performance concretes

    Directory of Open Access Journals (Sweden)

    Alessandra Lorenzetti de Castro

    2006-12-01

    Full Text Available Concrete is defined as a composite material and, in rheological terms, it can be understood as a concentrated suspension of solid particles (aggregates in a viscous liquid (cement paste. On a macroscopic scale, concrete flows as a liquid. It is known that the rheological behavior of the concrete is close to that of a Bingham fluid and two rheological parameters regarding its description are needed: yield stress and plastic viscosity. The aim of this paper is to present the initial rheological description of high performance concretes using the modified slump test. According to the results, an increase of yield stress was observed over time, while a slight variation in plastic viscosity was noticed. The incorporation of silica fume showed changes in the rheological properties of fresh concrete. The behavior of these materials also varied with the mixing procedure employed in their production. The addition of superplasticizer meant that there was a large reduction in the mixture's yield stress, while plastic viscosity remained practically constant.

  6. High thermoelectric performance of graphite nanofibers.

    Science.gov (United States)

    Tran, Van-Truong; Saint-Martin, Jérôme; Dollfus, Philippe; Volz, Sebastian

    2018-02-22

    Graphite nanofibers (GNFs) have been demonstrated to be a promising material for hydrogen storage and heat management in electronic devices. Here, by means of first-principles and transport simulations, we show that GNFs can also be an excellent material for thermoelectric applications thanks to the interlayer weak van der Waals interaction that induces low thermal conductance and a step-like shape in the electronic transmission with mini-gaps, which are necessary ingredients to achieve high thermoelectric performance. This study unveils that the platelet form of GNFs in which graphite layers are perpendicular to the fiber axis can exhibit outstanding thermoelectric properties with a figure of merit ZT reaching 3.55 in a 0.5 nm diameter fiber and 1.1 in a 1.1 nm diameter one. Interestingly, by introducing 14 C isotope doping, ZT can even be enhanced up to more than 5, and more than 8 if we include the effect of finite phonon mean free path, which demonstrates the amazing thermoelectric potential of GNFs.

  7. Durability of high performance concrete in seawater

    International Nuclear Information System (INIS)

    Amjad Hussain Memon; Salihuddin Radin Sumadi; Rabitah Handan

    2000-01-01

    This paper presents a report on the effects of blended cements on the durability of high performance concrete (HPC) in seawater. In this research the effect of seawater was investigated. The specimens were initially subjected to water curing for seven days inside the laboratory at room temperature, followed by seawater curing exposed to tidal zone until testing. In this study three levels of cement replacement (0%, 30% and 70%) were used. The combined use of chemical and mineral admixtures has resulted in a new generation of concrete called HPC. The HPC has been identified as one of the most important advanced materials necessary in the effort to build a nation's infrastructure. HPC opens new opportunities in the utilization of the industrial by-products (mineral admixtures) in the construction industry. As a matter of fact permeability is considered as one of the fundamental properties governing the durability of concrete in the marine environment. Results of this investigation indicated that the oxygen permeability values for the blended cement concretes at the age of one year are reduced by a factor of about 2 as compared to OPC control mix concrete. Therefore both blended cement concretes are expected to withstand in the seawater exposed to tidal zone without serious deterioration. (Author)

  8. Oxidative Stress-Responsive Apoptosis Inducing Protein (ORAIP) Plays a Critical Role in High Glucose-Induced Apoptosis in Rat Cardiac Myocytes and Murine Pancreatic β-Cells.

    Science.gov (United States)

    Yao, Takako; Fujimura, Tsutomu; Murayama, Kimie; Okumura, Ko; Seko, Yoshinori

    2017-10-18

    We previously identified a novel apoptosis-inducing humoral factor in the conditioned medium of hypoxic/reoxygenated-cardiac myocytes. We named this novel post-translationally-modified secreted-form of eukaryotic translation initiation factor 5A Oxidative stress-Responsive Apoptosis-Inducing Protein (ORAIP). We confirmed that myocardial ischemia/reperfusion markedly increased plasma ORAIP levels and rat myocardial ischemia/reperfusion injury was clearly suppressed by neutralizing anti-ORAIP monoclonal antibodies (mAbs) in vivo. In this study, to investigate the mechanism of cell injury of cardiac myocytes and pancreatic β-cells involved in diabetes mellitus (DM), we analyzed plasma ORAIP levels in DM model rats and the role of ORAIP in high glucose-induced apoptosis of cardiac myocytes in vitro. We also examined whether recombinant-ORAIP induces apoptosis in pancreatic β-cells. Plasma ORAIP levels in DM rats during diabetic phase were about 18 times elevated as compared with non-diabetic phase. High glucose induced massive apoptosis in cardiac myocytes (66.2 ± 2.2%), which was 78% suppressed by neutralizing anti-ORAIP mAb in vitro. Furthermore, recombinant-ORAIP clearly induced apoptosis in pancreatic β-cells in vitro. These findings strongly suggested that ORAIP plays a pivotal role in hyperglycemia-induced myocardial injury and pancreatic β-cell injury in DM. ORAIP will be a biomarker and a critical therapeutic target for cardiac injury and progression of DM itself.

  9. Alternative High-Performance Ceramic Waste Forms

    Energy Technology Data Exchange (ETDEWEB)

    Sundaram, S. K. [Alfred Univ., NY (United States)

    2017-02-01

    This final report (M5NU-12-NY-AU # 0202-0410) summarizes the results of the project titled “Alternative High-Performance Ceramic Waste Forms,” funded in FY12 by the Nuclear Energy University Program (NEUP Project # 12-3809) being led by Alfred University in collaboration with Savannah River National Laboratory (SRNL). The overall focus of the project is to advance fundamental understanding of crystalline ceramic waste forms and to demonstrate their viability as alternative waste forms to borosilicate glasses. We processed single- and multiphase hollandite waste forms based on simulated waste streams compositions provided by SRNL based on the advanced fuel cycle initiative (AFCI) aqueous separation process developed in the Fuel Cycle Research and Development (FCR&D). For multiphase simulated waste forms, oxide and carbonate precursors were mixed together via ball milling with deionized water using zirconia media in a polyethylene jar for 2 h. The slurry was dried overnight and then separated from the media. The blended powders were then subjected to melting or spark plasma sintering (SPS) processes. Microstructural evolution and phase assemblages of these samples were studied using x-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersion analysis of x-rays (EDAX), wavelength dispersive spectrometry (WDS), transmission electron spectroscopy (TEM), selective area x-ray diffraction (SAXD), and electron backscatter diffraction (EBSD). These results showed that the processing methods have significant effect on the microstructure and thus the performance of these waste forms. The Ce substitution into zirconolite and pyrochlore materials was investigated using a combination of experimental (in situ XRD and x-ray absorption near edge structure (XANES)) and modeling techniques to study these single phases independently. In zirconolite materials, a transition from the 2M to the 4M polymorph was observed with increasing Ce content. The resulting

  10. Regions of High Out-Of-Hospital Cardiac Arrest Incidence and Low Bystander CPR Rates in Victoria, Australia.

    Science.gov (United States)

    Straney, Lahn D; Bray, Janet E; Beck, Ben; Finn, Judith; Bernard, Stephen; Dyson, Kylie; Lijovic, Marijana; Smith, Karen

    2015-01-01

    Out-of-hospital cardiac arrest (OHCA) remains a major public health issue and research has shown that large regional variation in outcomes exists. Of the interventions associated with survival, the provision of bystander CPR is one of the most important modifiable factors. The aim of this study is to identify census areas with high incidence of OHCA and low rates of bystander CPR in Victoria, Australia. We conducted an observational study using prospectively collected population-based OHCA data from the state of Victoria in Australia. Using ArcGIS (ArcMap 10.0), we linked the location of the arrest using the dispatch coordinates (longitude and latitude) to Victorian Local Government Areas (LGAs). We used Bayesian hierarchical models with random effects on each LGA to provide shrunken estimates of the rates of bystander CPR and the incidence rates. Over the study period there were 31,019 adult OHCA attended, of which 21,436 (69.1%) cases were of presumed cardiac etiology. Significant variation in the incidence of OHCA among LGAs was observed. There was a 3 fold difference in the incidence rate between the lowest and highest LGAs, ranging from 38.5 to 115.1 cases per 100,000 person-years. The overall rate of bystander CPR for bystander witnessed OHCAs was 62.4%, with the rate increasing from 56.4% in 2008-2010 to 68.6% in 2010-2013. There was a 25.1% absolute difference in bystander CPR rates between the highest and lowest LGAs. Significant regional variation in OHCA incidence and bystander CPR rates exists throughout Victoria. Regions with high incidence and low bystander CPR participation can be identified and would make suitable targets for interventions to improve CPR participation rates.

  11. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed...... and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  12. Intelligent Facades for High Performance Green Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Dyson, Anna [Rensselaer Polytechnic Inst., Troy, NY (United States)

    2017-03-01

    Progress Towards Net-Zero and Net-Positive-Energy Commercial Buildings and Urban Districts Through Intelligent Building Envelope Strategies Previous research and development of intelligent facades systems has been limited in their contribution towards national goals for achieving on-site net zero buildings, because this R&D has failed to couple the many qualitative requirements of building envelopes such as the provision of daylighting, access to exterior views, satisfying aesthetic and cultural characteristics, with the quantitative metrics of energy harvesting, storage and redistribution. To achieve energy self-sufficiency from on-site solar resources, building envelopes can and must address this gamut of concerns simultaneously. With this project, we have undertaken a high-performance building integrated combined-heat and power concentrating photovoltaic system with high temperature thermal capture, storage and transport towards multiple applications (BICPV/T). The critical contribution we are offering with the Integrated Concentrating Solar Façade (ICSF) is conceived to improve daylighting quality for improved health of occupants and mitigate solar heat gain while maximally capturing and transferring onsite solar energy. The ICSF accomplishes this multi-functionality by intercepting only the direct-normal component of solar energy (which is responsible for elevated cooling loads) thereby transforming a previously problematic source of energy into a high quality resource that can be applied to building demands such as heating, cooling, dehumidification, domestic hot water, and possible further augmentation of electrical generation through organic Rankine cycles. With the ICSF technology, our team is addressing the global challenge in transitioning commercial and residential building stock towards on-site clean energy self-sufficiency, by fully integrating innovative environmental control systems strategies within an intelligent and responsively dynamic building

  13. High-performance commercial building systems

    Energy Technology Data Exchange (ETDEWEB)

    Selkowitz, Stephen

    2003-10-01

    This report summarizes key technical accomplishments resulting from the three year PIER-funded R&D program, ''High Performance Commercial Building Systems'' (HPCBS). The program targets the commercial building sector in California, an end-use sector that accounts for about one-third of all California electricity consumption and an even larger fraction of peak demand, at a cost of over $10B/year. Commercial buildings also have a major impact on occupant health, comfort and productivity. Building design and operations practices that influence energy use are deeply engrained in a fragmented, risk-averse industry that is slow to change. Although California's aggressive standards efforts have resulted in new buildings designed to use less energy than those constructed 20 years ago, the actual savings realized are still well below technical and economic potentials. The broad goal of this program is to develop and deploy a set of energy-saving technologies, strategies, and techniques, and improve processes for designing, commissioning, and operating commercial buildings, while improving health, comfort, and performance of occupants, all in a manner consistent with sound economic investment practices. Results are to be broadly applicable to the commercial sector for different building sizes and types, e.g. offices and schools, for different classes of ownership, both public and private, and for owner-occupied as well as speculative buildings. The program aims to facilitate significant electricity use savings in the California commercial sector by 2015, while assuring that these savings are affordable and promote high quality indoor environments. The five linked technical program elements contain 14 projects with 41 distinct R&D tasks. Collectively they form a comprehensive Research, Development, and Demonstration (RD&D) program with the potential to capture large savings in the commercial building sector, providing significant economic benefits to

  14. AICAR Protects against High Palmitate/High Insulin-Induced Intramyocellular Lipid Accumulation and Insulin Resistance in HL-1 Cardiac Cells by Inducing PPAR-Target Gene Expression

    Directory of Open Access Journals (Sweden)

    Ricardo Rodríguez-Calvo

    2015-01-01

    Full Text Available Here we studied the impact of 5-aminoimidazole-4-carboxamide riboside (AICAR, a well-known AMPK activator, on cardiac metabolic adaptation. AMPK activation by AICAR was confirmed by increased phospho-Thr172-AMPK and phospho-Ser79-ACC protein levels in HL-1 cardiomyocytes. Then, cells were exposed to AICAR stimulation for 24 h in the presence or absence of the AMPK inhibitor Compound C, and the mRNA levels of the three PPARs were analyzed by real-time RT-PCR. Treatment with AICAR induced gene expression of all three PPARs, but only the Ppara and Pparg regulation were dependent on AMPK. Next, we exposed HL-1 cells to high palmitate/high insulin (HP/HI conditions either in presence or in absence of AICAR, and we evaluated the expression of selected PPAR-targets genes. HP/HI induced insulin resistance and lipid storage was accompanied by increased Cd36, Acot1, and Ucp3 mRNA levels. AICAR treatment induced the expression of Acadvl and Glut4, which correlated to prevention of the HP/HI-induced intramyocellular lipid build-up, and attenuation of the HP/HI-induced impairment of glucose uptake. These data support the hypothesis that AICAR contributes to cardiac metabolic adaptation via regulation of transcriptional mechanisms.

  15. Prognostic implications of high-sensitivity cardiac troponin T assay in a real-world population with non-ST-elevation acute coronary syndrome.

    Science.gov (United States)

    Magnoni, Marco; Gallone, Guglielmo; Ceriotti, Ferruccio; Vergani, Vittoria; Giorgio, Daniela; Angeloni, Giulia; Maseri, Attilio; Cianflone, Domenico

    2018-09-01

    High-sensitivity cardiac troponin T (hsTnT) was recently approved for clinical use by the Food and Drug Administration. The transition from contemporary to hsTnT assays requires a thorough understanding of the clinical differences between these assays. HsTnT may provide a more accurate prognostic stratification than contemporary cardiac troponin I (cTnI) in patients with non-ST-segment elevation acute coronary syndromes (NSTE-ACS). HsTnT and cTnI were measured in 644 patients with CK-MB negative NSTE-ACS who were enrolled in the prospective multicenter SPAI (Stratificazione Prognostica dell'Angina Instabile) study. Patients were stratified at the 99th percentile reference limit for each assay. The primary endpoint was cardiovascular death (CVD) or non-fatal myocardial infarction (MI); the secondary endpoint was the occurrence of unstable angina (UA). Follow-up lasted 180 days. Patients with hsTnT ≥99th percentile were at higher risk of CVD/MI (30-day: 5.9% vs 0.8%, p  = 0.001; 180-day: 11.1% vs 4.7%, p  = 0.004), also after adjusting for TIMI Risk Score. No significant difference in CVD/MI at 180-day was found between hsTnT-positive/cTnI-negative and hsTnT-negative/cTnI-negative patients (adjHR 1.61, 95% CI 0.74-3.49, p  = 0.232). Occurrence of UA was not differently distributed between hsTnT groups dichotomized at the 99th percentile (12.4% vs 12.5% p  = 0.54). Our investigation on a real-world NSTE-ACS population showed good prognostic performance of hsTnT in the risk stratification of the hard endpoint, but did not demonstrate the improved prognostic ability of hsTnT over contemporary cTn. Neither troponin assay predicted the recurrence of UA, suggesting the acute rise of cardiac troponin as a marker of severity, but not the occurrence of future coronary instability.

  16. Novel all-extremity high-intensity interval training improves aerobic fitness, cardiac function and insulin resistance in healthy older adults.

    Science.gov (United States)

    Hwang, Chueh-Lung; Yoo, Jeung-Ki; Kim, Han-Kyul; Hwang, Moon-Hyon; Handberg, Eileen M; Petersen, John W; Christou, Demetra D

    2016-09-01

    Aging is associated with decreased aerobic fitness and cardiac remodeling leading to increased risk for cardiovascular disease. High-intensity interval training (HIIT) on the treadmill has been reported to be more effective in ameliorating these risk factors compared with moderate-intensity continuous training (MICT) in patients with cardiometabolic disease. In older adults, however, weight-bearing activities are frequently limited due to musculoskeletal and balance problems. The purpose of this study was to examine the feasibility and safety of non-weight-bearing all-extremity HIIT in older adults. In addition, we tested the hypothesis that all-extremity HIIT will be more effective in improving aerobic fitness, cardiac function, and metabolic risk factors compared with all-extremity MICT. Fifty-one healthy sedentary older adults (age: 65±1years) were randomized to HIIT (n=17), MICT (n=18) or non-exercise control (CONT; n=16). HIIT (4×4min 90% of peak heart rate; HRpeak) and isocaloric MICT (70% of HRpeak) were performed on a non-weight-bearing all-extremity ergometer, 4×/week for 8weeks under supervision. All-extremity HIIT was feasible in older adults and resulted in no adverse events. Aerobic fitness (peak oxygen consumption; VO2peak) and ejection fraction (echocardiography) improved by 11% (PHIIT, while no changes were observed in MICT and CONT (P≥0.1). Greater improvements in ejection fraction were associated with greater improvements in VO2peak (r=0.57; PHIIT by 26% (P=0.016). Diastolic function, body composition, glucose and lipids were unaffected (P≥0.1). In conclusion, all-extremity HIIT is feasible and safe in older adults. HIIT, but not MICT, improved aerobic fitness, ejection fraction, and insulin resistance. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Novel All-Extremity High-Intensity Interval Training Improves Aerobic Fitness, Cardiac Function and Insulin Resistance in Healthy Older Adults

    Science.gov (United States)

    Hwang, Chueh-Lung; Yoo, Jeung-Ki; Kim, Han-Kyul; Hwang, Moon-Hyon; Handberg, Eileen M.; Petersen, John W.; Christou, Demetra D.

    2016-01-01

    Aging is associated with decreased aerobic fitness and cardiac remodeling leading to increased risk for cardiovascular disease. High-intensity interval training (HIIT) on the treadmill has been reported to be more effective in ameliorating these risk factors compared with moderate-intensity continuous training (MICT) in patients with cardiometabolic disease. In older adults, however, weight-bearing activities are frequently limited due to musculoskeletal and balance problems. The purpose of this study was to examine the feasibility and safety of non-weight-bearing all-extremity HIIT in older adults. In addition, we tested the hypothesis that all-extremity HIIT will be more effective in improving aerobic fitness, cardiac function, and metabolic risk factors compared with all-extremity MICT. Fifty-one healthy sedentary older adults (age: 65±1 years) were randomized to HIIT (n=17), MICT (n=18) or non-exercise control (CONT; n=16). HIIT (4×4 minutes 90% of peak heart rate; HRpeak) and isocaloric MICT (70% of HRpeak) were performed on a non-weight-bearing all-extremity ergometer, 4x/week for 8 weeks under supervision. All-extremity HIIT was feasible in older adults and resulted in no adverse events. Aerobic fitness (peak oxygen consumption; VO2peak) and ejection fraction (echocardiography) improved by 11% (PHIIT, while no changes were observed in MICT and CONT (P≥0.1). Greater improvements in ejection fraction were associated with greater improvements in VO2peak (r=0.57; PHIIT by 26% (P=0.016). Diastolic function, body composition, glucose and lipids were unaffected (P≥0.1). In conclusion, all-extremity HIIT is feasible and safe in older adults. HIIT, but not MICT, improved aerobic fitness, ejection fraction, and insulin resistance. PMID:27346646

  18. Alteration in cardiac uncoupling proteins and eNOS gene expression following high-intensity interval training in favor of increasing mechanical efficiency.

    Science.gov (United States)

    Fallahi, Ali Asghar; Shekarfroush, Shahnaz; Rahimi, Mostafa; Jalali, Amirhossain; Khoshbaten, Ali

    2016-03-01

    High-intensity interval training (HIIT) increases energy expenditure and mechanical energy efficiency. Although both uncoupling proteins (UCPs) and endothelial nitric oxide synthase (eNOS) affect the mechanical efficiency and antioxidant capacity, their effects are inverse. The aim of this study was to determine whether the alterations of cardiac UCP2, UCP3, and eNOS mRNA expression following HIIT are in favor of increased mechanical efficiency or decreased oxidative stress. Wistar rats were divided into five groups: control group (n=12), HIIT for an acute bout (AT1), short term HIIT for 3 and 5 sessions (ST3 and ST5), long-term training for 8 weeks (LT) (6 in each group). The rats of the training groups were made to run on a treadmill for 60 min in three stages: 6 min running for warm-up, 7 intervals of 7 min running on treadmill with a slope of 5° to 20° (4 min with an intensity of 80-110% VO2max and 3 min at 50-60% VO2max), and 5-min running for cool-down. The control group did not participate in any exercise program. Rats were sacrificed and the hearts were extracted to analyze the levels of UCP2, UCP3 and eNOS mRNA by RT-PCR. UCP3 expression was increased significantly following an acute training bout. Repeated HIIT for 8 weeks resulted in a significant decrease in UCPs mRNA and a significant increase in eNOS expression in cardiac muscle. This study indicates that Long term HIIT through decreasing UCPs mRNA and increasing eNOS mRNA expression may enhance energy efficiency and physical performance.

  19. Improving the high performance concrete (HPC behaviour in high temperatures

    Directory of Open Access Journals (Sweden)

    Cattelan Antocheves De Lima, R.

    2003-12-01

    Full Text Available High performance concrete (HPC is an interesting material that has been long attracting the interest from the scientific and technical community, due to the clear advantages obtained in terms of mechanical strength and durability. Given these better characteristics, HFC, in its various forms, has been gradually replacing normal strength concrete, especially in structures exposed to severe environments. However, the veiy dense microstructure and low permeability typical of HPC can result in explosive spalling under certain thermal and mechanical conditions, such as when concrete is subject to rapid temperature rises, during a f¡re. This behaviour is caused by the build-up of internal water pressure, in the pore structure, during heating, and by stresses originating from thermal deformation gradients. Although there are still a limited number of experimental programs in this area, some researchers have reported that the addition of polypropylene fibers to HPC is a suitable way to avoid explosive spalling under f re conditions. This change in behavior is derived from the fact that polypropylene fibers melt in high temperatures and leave a pathway for heated gas to escape the concrete matrix, therefore allowing the outward migration of water vapor and resulting in the reduction of interned pore pressure. The present research investigates the behavior of high performance concrete on high temperatures, especially when polypropylene fibers are added to the mix.

    El hormigón de alta resistencia (HAR es un material de gran interés para la comunidad científica y técnica, debido a las claras ventajas obtenidas en término de resistencia mecánica y durabilidad. A causa de estas características, el HAR, en sus diversas formas, en algunas aplicaciones está reemplazando gradualmente al hormigón de resistencia normal, especialmente en estructuras expuestas a ambientes severos. Sin embargo, la microestructura muy densa y la baja permeabilidad t

  20. 5 A study analysing the diagnostic performance of ECG interpretation for 30-day major cardiac events in the emergency department.

    Science.gov (United States)

    Morris, Niall; Body, Rick

    2017-12-01

    This study evaluates the diagnostic accuracy of an Emergency Medicine (EM) clinician at identifying ischaemia on an ECG using 30-day major adverse cardiac events (MACE) as the primary outcome. This is a secondary analysis of a prospective, multi-centre, observational cohort at 14 centres: the Bedside Evaluation of Sensitive Troponin study. All fourteen Emergency Departments were based in the United Kingdom. Emergency physicians' assessments of the ECG were collected using a standardised form. Clinicians were asked to judge whether the ECG demonstrated ischaemia, the presence of ST depression (STD) and if there was abnormal T wave inversion (ATWI). Patients provided written informed consent and underwent serial high sensitivity troponin testing. 30 day follow-up was performed by research nurses using a standardised form via telephone. The primary outcome was 30-day major adverse cardiac events, defined as acute myocardial infarction, any cause of death and coronary revascularisation. In total, 756 patients were included in the analysis. Clinicians' ECG diagnosis of ischaemia for 30-day MACE: ECG ischaemia produces a sensitivity (Sn) of 19.54% (95% CI:11.81% to 29.43%), specificity (Sp) of 93.27% (95% CI:91.10% to 95.05%), positive predictive value (PPV) of 27.42% (95% CI:18.47% to 38.65%) and negative predictive value (NPV) of 89.91% (95%CI 88.92% to 90.83%). ECG ST depression produces Sn of 16.09% (9.09% to 25.52%), Sp of 89.69% (87.13% to 91.89%), PPV 16.87 (10.68% to 25.62%), and NPV 89.15% (88.19% to 90.04%). ECG ATWI produces Sn of 4.60% (1.27% to 11.36%), Sp of 91.63% (89.27% to 93.62%), PPV of 6.67% (2.59% to 16.12%) and NPV of 88.07% (87.52% to 88.6). This is the first prospective, multi-centre cohort study, that assess the diagnostic performance of EM clinician's ECG interpretation, with 30-day MACE as the primary outcome. The findings are highly relevant to EM as they represent the ECG terms used by popular acute coronary syndrome clinical decision rules

  1. Spectrally high performing quantum cascade lasers

    Science.gov (United States)

    Toor, Fatima

    Quantum cascade (QC) lasers are versatile semiconductor light sources that can be engineered to emit light of almost any wavelength in the mid- to far-infrared (IR) and terahertz region from 3 to 300 mum [1-5]. Furthermore QC laser technology in the mid-IR range has great potential for applications in environmental, medical and industrial trace gas sensing [6-10] since several chemical vapors have strong rovibrational frequencies in this range and are uniquely identifiable by their absorption spectra through optical probing of absorption and transmission. Therefore, having a wide range of mid-IR wavelengths in a single QC laser source would greatly increase the specificity of QC laser-based spectroscopic systems, and also make them more compact and field deployable. This thesis presents work on several different approaches to multi-wavelength QC laser sources that take advantage of band-structure engineering and the uni-polar nature of QC lasers. Also, since for chemical sensing, lasers with narrow linewidth are needed, work is presented on a single mode distributed feedback (DFB) QC laser. First, a compact four-wavelength QC laser source, which is based on a 2-by-2 module design, with two waveguides having QC laser stacks for two different emission wavelengths each, one with 7.0 mum/11.2 mum, and the other with 8.7 mum/12.0 mum is presented. This is the first design of a four-wavelength QC laser source with widely different emission wavelengths that uses minimal optics and electronics. Second, since there are still several unknown factors that affect QC laser performance, results on a first ever study conducted to determine the effects of waveguide side-wall roughness on QC laser performance using the two-wavelength waveguides is presented. The results are consistent with Rayleigh scattering effects in the waveguides, with roughness effecting shorter wavelengths more than longer wavelengths. Third, a versatile time-multiplexed multi-wavelength QC laser system that

  2. [Computer cardiokymography. On its way to long-term noninvasive monitoring of cardiac performance in daly life].

    Science.gov (United States)

    Khaiutin, V M; Lukoshkova, E V; Sheroziia, G G

    2004-05-01

    A functioning heart generates low-frequency and low-amplitude movements (up to 40 (mrn) of soft tissues in the percardial area. Since the 1950-s of the XX-th century cardiologists have studied these movements to employ them in the diagnostics of ischemic heart disease (IHD). Indeed, changes of the movements have found their diagnostic application in this field. If blood supply to a certain area of ventricular myocardium is insufficient the contractions in this area diminish and even ceases. After systolic increase in ventricular pressure this area dilates and forces intercostal tissues out, causing a "bulge" wave on the record. For recording the patient must be in supine position and hold the breath. High frequency electromagnetic field generator was used in an attempt to examine the heart movements. It was found that such instrument measures the thickness of the air-gap that serves as a dielectric or a "capacitor" which forms between the skin and approaching it flat inductive coil. Nevertheless, such an instrument (cardiokymograph, CKG) can reveal changes in contractions of ischemic myocardium and markedly increases the sensitivity of the exercise ECG test. However, CKG can be recorded only after termination of the test. This principal disadvantage has been overcome by software that allowed the recording of CKG during the test. A low-frequency capacitance transducer developed recently by Chinese researchers has provided a simultaneous recording of several CKG. After modifying the transducer, we have established that 1) the shape of CKGs is the same as that CKGs recorded by all our predecessors, 2) CKGs are reproducible even within a 3-month interval, 3) the enormous mechanical interference caused by respiratory movements and, to a greater extent, by the vigorous movements of the legs and trunk during veloergometry can be eliminated by digital processing of the transducer signals, and 4) pathological changes appear in CKG of patients with IHD, which enables one to

  3. Nova performance at ultra high fluence levels

    International Nuclear Information System (INIS)

    Hunt, J.T.

    1986-01-01

    Nova is a ten beam high power Nd:glass laser used for interial confinement fusion research. It was operated in the high power high energy regime following the completion of construction in December 1984. During this period several interesting nonlinear optical phenomena were observed. These phenomena are discussed in the text. 11 refs., 5 figs

  4. Durability and Performance of High Performance Infiltration Cathodes

    DEFF Research Database (Denmark)

    Samson, Alfred Junio; Søgaard, Martin; Hjalmarsson, Per

    2013-01-01

    The performance and durability of solid oxide fuel cell (SOFC) cathodes consisting of a porous Ce0.9Gd0.1O1.95 (CGO) infiltrated with nitrates corresponding to the nominal compositions La0.6Sr0.4Co1.05O3-δ (LSC), LaCoO3-δ (LC), and Co3O4 are discussed. At 600°C, the polarization resistance, Rp......, varied as: LSC (0.062Ωcm2)cathode was found to depend on the infiltrate firing temperature and is suggested to originate...... of the infiltrate but also from a better surface exchange property. A 450h test of an LSC-infiltrated CGO cathode showed an Rp with final degradation rate of only 11mΩcm2kh-1. An SOFC with an LSC-infiltrated CGO cathode tested for 1,500h at 700°C and 0.5Acm-2 (60% fuel, 20% air utilization) revealed no measurable...

  5. High-dose stabilized chlorite matrix WF10 prolongs cardiac xenograft survival in the hamster-to-rat model without inducing ultrastructural or biochemical signs of cardiotoxicity

    DEFF Research Database (Denmark)

    Hansen, A; Kemp, K; Kemp, E

    2001-01-01

    of high dose WF10 as a single drug regimen in the hamster-to-rat xenotransplantation model and searched for possible cardiotoxic side effects. WF10 prolonged cardiac xenograft survival, but did not induce tolerence or inhibit pathological signs of acute rejection. Hamsters from the donor population...

  6. High Performance Computing in Science and Engineering '02 : Transactions of the High Performance Computing Center

    CERN Document Server

    Jäger, Willi

    2003-01-01

    This book presents the state-of-the-art in modeling and simulation on supercomputers. Leading German research groups present their results achieved on high-end systems of the High Performance Computing Center Stuttgart (HLRS) for the year 2002. Reports cover all fields of supercomputing simulation ranging from computational fluid dynamics to computer science. Special emphasis is given to industrially relevant applications. Moreover, by presenting results for both vector sytems and micro-processor based systems the book allows to compare performance levels and usability of a variety of supercomputer architectures. It therefore becomes an indispensable guidebook to assess the impact of the Japanese Earth Simulator project on supercomputing in the years to come.

  7. Reporting of coronary artery calcification on chest CT studies in breast cancer patients at high risk of cancer therapy related cardiac events

    Directory of Open Access Journals (Sweden)

    William J. Phillips

    2018-03-01

    Full Text Available Background: The identification of coronary artery calcification (CAC detected coincidentally on chest CT exams could assist in cardiovascular risk assessment but may not be reported consistently on clinical studies. Cardiovascular risk factor stratification is important to predict short term cardiac events during cancer therapy and long term cardiac event free survival in cancer patients. We sought to determine the prevalence of CAC and clinical reporting rates in a cohort of cancer patients at high risk of cancer therapy related cardiac events. Methods: 408 Breast cancer patients who were referred to a cardiac oncology clinic were screened. Inclusion criteria included having had a CT chest and the absence of known coronary disease. Among those screened 263 patients were included in the study. Results: CAC was identified in 70 patients (26%. CAC was reported in 18% of studies. The reporting rates of CAC increased with the extent of coronary calcification (p < 0.01 and increased during the period of the study (p < 0.05. Conclusions: CAC was commonly detected on chest CT studies in this observational study of breast cancer patients at high risk of cardiac oncology events. The presence of CAC was often not reported clinically but reporting rates have increased over time. Recent SCCT/STR guidelines recommend reporting the presence of CAC on routine chest CT scans in recognition of the importance of CAC as a predictor of cardiovascular events. Reporting of CAC on chest CTs may help to further risk stratify breast cancer patients and improve cardiovascular outcomes in this vulnerable population. Keywords: Cardiac oncology, Coronary calcification and chest CT

  8. From adaptive to high-performance structures

    NARCIS (Netherlands)

    Teuffel, P.

    2011-01-01

    Multiple design aspects influence the building performance such as architectural criteria, various environmental impacts and user behaviour. Specific examples are sun, wind, temperatures, function, occupancy, socio-cultural aspects and other contextual aspects and needs. Even though these aspects

  9. High-Intensity Exercise Reduces Cardiac Fibrosis and Hypertrophy but Does Not Restore the Nitroso-Redox Imbalance in Diabetic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Ulises Novoa

    2017-01-01

    Full Text Available Diabetic cardiomyopathy refers to the manifestations in the heart as a result of altered glucose homeostasis, reflected as fibrosis, cellular hypertrophy, increased oxidative stress, and apoptosis, leading to ventricular dysfunction. Since physical exercise has been indicated as cardioprotective, we tested the hypothesis that high-intensity exercise training could reverse the cardiac maladaptations produced by diabetes. For this, diabetes was induced in rats by a single dose of alloxan. Diabetic rats were randomly assigned to a sedentary group or submitted to a program of exercise on a treadmill for 4 weeks at 80% of maximal performance. Another group of normoglycemic rats was used as control. Diabetic rat hearts presented cardiomyocyte hypertrophy and interstitial fibrosis. Chronic exercise reduced both parameters but increased apoptosis. Diabetes increased the myocardial levels of the mRNA and proteins of NADPH oxidases NOX2 and NOX4. These altered levels were not reduced by exercise. Diabetes also increased the level of uncoupled endothelial nitric oxide synthase (eNOS that was not reversed by exercise. Finally, diabetic rats showed a lower degree of phosphorylated phospholamban and reduced levels of SERCA2 that were not restored by high-intensity exercise. These results suggest that high-intensity chronic exercise was able to reverse remodeling in the diabetic heart but was unable to restore the nitroso-redox imbalance imposed by diabetes.

  10. c-kitpos GATA-4 high rat cardiac stem cells foster adult cardiomyocyte survival through IGF-1 paracrine signalling.

    Directory of Open Access Journals (Sweden)

    Nanako Kawaguchi

    2010-12-01

    Full Text Available Resident c-kit positive (c-kitpos cardiac stem cells (CSCs could be considered the most appropriate cell type for myocardial regeneration therapies. However, much is still unknown regarding their biological properties and potential.We produced clones of high and low expressing GATA-4 CSCs from long-term bulk-cultured c-kitpos CSCs isolated from adult rat hearts. When c-kitpos GATA-4 high expressing clonal CSCs (cCSCs were co-cultured with adult rat ventricular cardiomyocytes, we observed increased survival and contractility of the cardiomyocytes, compared to cardiomyocytes cultured alone, co-cultured with fibroblasts or c-kitpos GATA-4 low expressing cCSCs. When analysed by ELISA, the concentration of IGF-1 was significantly increased in the c-kitpos GATA-4 high cCSC/cardiomyocyte co-cultures and there was a significant correlation between IGF-1 concentration and cardiomyocyte survival. We showed the activation of the IGF-1 receptor and its downstream molecular targets in cardiomyocytes co-cultured with c-kitpos GATA-4 high cCSCs but not in cardiomyocytes that were cultured alone, co-cultured with fibroblasts or c-kitpos GATA-4 low cCSCs. Addition of a blocking antibody specific to the IGF-1 receptor inhibited the survival of cardiomyocytes and prevented the activation of its signalling in cardiomyocytes in the c-kitpos GATA-4 high cCSC/cardiomyocyte co-culture system. IGF-1 supplementation or IGF-1 high conditioned medium taken from the co-culture of c-kitpos GATA-4 high cCSCs plus cardiomyocytes did extend the survival and contractility of cardiomyocytes cultured alone and cardiomyocytes co-cultured with c-kitpos GATA-4 low cCSCs.c-kitpos GATA-4 high cCSCs exert a paracrine survival effect on cardiomyocytes through induction of the IGF-1R and signalling pathway.

  11. High-performance-vehicle technology. [fighter aircraft propulsion

    Science.gov (United States)

    Povinelli, L. A.

    1979-01-01

    Propulsion needs of high performance military aircraft are discussed. Inlet performance, nozzle performance and cooling, and afterburner performance are covered. It is concluded that nonaxisymmetric nozzles provide cleaner external lines and enhanced maneuverability, but the internal flows are more complex. Swirl afterburners show promise for enhanced performance in the high altitude, low Mach number region.

  12. Cardiac computed tomography in patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Schlett, C.L.; Bamberg, F.

    2014-01-01

    Currently, cardiac computed tomography (CT) is increasingly being implemented into clinical algorithms, primarily due to substantial technical advances over the last decade. Its use in the setting of suspected acute coronary syndrome is of particular relevance, given the high degree of accumulating scientific evidence of improving patient outcomes. Performing cardiac CT requires specific knowledge on the available scan acquisitions and patient preparation. Also, expertise is required in order to interpret the coronary and extra-coronary findings adequately. The present article provides an overview of the different aspects on the use of cardiac CT in the setting of acute coronary syndrome.

  13. Influence of high- and low-LET radiation on the cardiac differentiation of mouse embryonic stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Helm, Alexander

    2013-07-19

    The in utero exposure to ionising radiation poses a risk for the radiosensitive developing embryo. Effects of low-LET radiation on different developmental stages of the embryo are relatively well known due to experimental studies and epidemiological data. Data for effects on the very early stage of the embryonic development, particularly the effects of high-LET radiation instead are rather limited. However, unanticipated exposures of the early embryo to ionising radiation may occur through diagnostic or therapeutic applications or through radiation accidents. Additionally, protons and carbon ions are increasingly used in radiotherapy. Thus, a risk estimation of high-LET exposure especially to the early embryo is of a certain importance. To address this topic, pluripotent mouse embryonic stem cells resembling the blastocyst stage were irradiated with high-LET carbon ions or low-LET X-rays and subsequently differentiated to mimic the early embryonic development. The occurrence of spontaneously contracting cardiomyocytes was used as a marker to asses the radiation effects on the differentiation. Among others, cell inactivation, cell death and gene expression were analysed. A delay in the cardiac differentiation after radiation exposure was found. The results point to radiation-induced cell killing as the main effector of the developmental delay. Carbon ions were found to be more effective than X-rays.

  14. High glucose induced oxidative stress and apoptosis in cardiac microvascular endothelial cells are regulated by FoxO3a.

    Directory of Open Access Journals (Sweden)

    Chaoming Peng

    Full Text Available Cardiac microvascular endothelial cells (CMECs dysfunction contributes to cardiovascular complications in diabetes, whereas, the underlying mechanism is not fully clarified. FoxO transcription factors are involved in apoptosis and reactive oxygen species (ROS production. Therefore, the present study was designed to elucidate the potential role of FoxO3a on the CMECs injury induced by high glucose.CMECs were isolated from hearts of adult rats and cultured in normal or high glucose medium for 6 h, 12 h and 24 h respectively. To down-regulate FoxO3a expression, CMECs were transfected with FoxO3a siRNA. ROS accumulation and apoptosis in CMECs were assessed by dihydroethidine (DHE staining and TUNEL assay respectively. Moreover, the expressions of Akt, FoxO3a, Bim and BclxL in CMECs were assessed by Western blotting assay.ROS accumulation in CMECs was significantly increased after high glucose incubation for 6 to 24 h. Meanwhile, high glucose also increased apoptosis in CMECs, correlated with decreased the phosphorylation expressions of Akt and FoxO3a. Moreover, high glucose incubation increased the expression of Bim, whereas increased anti-apoptotic protein BclxL. Furthermore, siRNA target FoxO3a silencing enhanced the ROS accumulation, whereas suppressed apoptosis in CMECs. FoxO3a silencing also abolished the disturbance of Bcl-2 proteins induced by high glucose in CMECs.Our data provide evidence that high glucose induced FoxO3a activation which suppressed ROS accumulation, and in parallel, resulted in apoptosis of CMECs.

  15. RISC Processors and High Performance Computing

    Science.gov (United States)

    Bailey, David H.; Saini, Subhash; Craw, James M. (Technical Monitor)

    1995-01-01

    This tutorial will discuss the top five RISC microprocessors and the parallel systems in which they are used. It will provide a unique cross-machine comparison not available elsewhere. The effective performance of these processors will be compared by citing standard benchmarks in the context of real applications. The latest NAS Parallel Benchmarks, both absolute performance and performance per dollar, will be listed. The next generation of the NPB will be described. The tutorial will conclude with a discussion of future directions in the field. Technology Transfer Considerations: All of these computer systems are commercially available internationally. Information about these processors is available in the public domain, mostly from the vendors themselves. The NAS Parallel Benchmarks and their results have been previously approved numerous times for public release, beginning back in 1991.

  16. A high performance thermoacoustic Stirling-engine

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, M.E.H.; Spoelstra, S. [Energy research Centre of the Netherlands (ECN), PO Box 1, 1755 ZG Petten (Netherlands)

    2011-11-10

    In thermoacoustic systems heat is converted into acoustic energy and vice versa. These systems use inert gases as working medium and have no moving parts which makes the thermoacoustic technology a serious alternative to produce mechanical or electrical power, cooling power, and heating in a sustainable and environmentally friendly way. A thermoacoustic Stirling heat engine is designed and built which achieves a record performance of 49% of the Carnot efficiency. The design and performance of the engine is presented. The engine has no moving parts and is made up of few simple components.

  17. Psychological factors in developing high performance athletes

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Wikman, Johan Michael

    2017-01-01

    calls for great efforts in dealing with competitive pressure and demands mental strength with regard to endurance, self-motivation and willpower. But while it is somewhat straightforward to specify the physical and physiological skills needed for top performance in a specific sport, it becomes less...... clear with regard to the psychological skills that are needed. Therefore, the main questions to be addressed in this chapter are: (1) which psychological skills are needed to reach top performance? And (2) (how) can these skills be developed in young talents?...

  18. High Performance Expectations: Concept and causes

    DEFF Research Database (Denmark)

    Andersen, Lotte Bøgh; Jacobsen, Christian Bøtcher

    2017-01-01

    literature research, HPE is defined as the degree to which leaders succeed in expressing ambitious expectations to their employees’ achievement of given performance criteria, and it is analyzed how leadership behavior affects employee-perceived HPE. This study applies a large-scale leadership field...... experiment with 3,730 employees nested in 471 organizations and finds that transformational leadership training as well as transactional and combined training of the leaders significantly increased employees’ HPE relative to a control group. Furthermore, transformational leadership and the use of pecuniary...... rewards seem to be important mechanisms. This implies that public leaders can actually affect HPE through their leadership and thus potentially organizational performance as well....

  19. High Rate Performing Li-ion Battery

    Science.gov (United States)

    2015-02-09

    journal article will be sufficient in most cases. This document may be as long or as short as needed to give a fair account of the work performed...Klink, J. J. & Moser, J. EPR Study of Vanadium (4+) in the Anatase and Rutile Phases of TiO2. Phys. Rev. B 34, 3060-3068 (1986). 40 Abragam, A

  20. Engendering a high performing organisational culture through ...

    African Journals Online (AJOL)

    Concluding that Africa's poor organisational performances are attributable to some inadequacies in the cultural foundations of countries and organisations, this paper argues for internal branding as the way forward for African organisations. Through internal branding an African organization can use a systematic and ...

  1. Mastering JavaScript high performance

    CERN Document Server

    Adams, Chad R

    2015-01-01

    If you are a JavaScript developer with some experience in development and want to increase the performance of JavaScript projects by building faster web apps, then this book is for you. You should know the basic concepts of JavaScript.

  2. Gamma and Xray spectroscopy at high performance

    International Nuclear Information System (INIS)

    Borchert, G.L.

    1984-01-01

    The author determines that for many interesting problems in gamma and Xray spectroscopy it is necessary to use crystal diffractometers. The basic features of such instruments are discussed and the special performance of crystal spectrometers is demonstrated by means of typical examples of various applications

  3. High Performance Fortran for Aerospace Applications

    National Research Council Canada - National Science Library

    Mehrotra, Piyush

    2000-01-01

    .... HPF is a set of Fortran extensions designed to provide users with a high-level interface for programming data parallel scientific applications while delegating to the compiler/runtime system the task...

  4. High-Performance Computing Paradigm and Infrastructure

    CERN Document Server

    Yang, Laurence T

    2006-01-01

    With hyperthreading in Intel processors, hypertransport links in next generation AMD processors, multi-core silicon in today's high-end microprocessors from IBM and emerging grid computing, parallel and distributed computers have moved into the mainstream

  5. High performance management bij franchise-supermarkten

    NARCIS (Netherlands)

    Sloot, Laurens; van Nierop, Erjen; de Waal, Andre

    In dit artikel wordt een onderzoek gepresenteerd naar de mate waarin franchise-supermarkten voldoen aan de vijf factoren van high performanceorganisaties (HPO): hoge kwaliteit managers, hoge kwaliteit medewerkers, openheid en actiegerichtheid, continue verbetering en vernieuwing, en

  6. High performance fuel technology development : Development of high performance cladding materials

    International Nuclear Information System (INIS)

    Park, Jeongyong; Jeong, Y. H.; Park, S. Y.

    2012-04-01

    The superior in-pile performance of the HANA claddings have been verified by the successful irradiation test and in the Halden research reactor up to the high burn-up of 67GWD/MTU. The in-pile corrosion and creep resistances of HANA claddings were improved by 40% and 50%, respectively, over Zircaloy-4. HANA claddings have been also irradiated in the commercial reactor up to 2 reactor cycles, showing the corrosion resistance 40% better than that of ZIRLO in the same fuel assembly. Long-term out-of-pile performance tests for the candidates of the next generation cladding materials have produced the highly reliable test results. The final candidate alloys were selected and they showed the corrosion resistance 50% better than the foreign advanced claddings, which is beyond the original target. The LOCA-related properties were also improved by 20% over the foreign advanced claddings. In order to establish the optimal manufacturing process for the inner and outer claddings of the dual-cooled fuel, 18 different kinds of specimens were fabricated with various cold working and annealing conditions. Based on the performance tests and various out-of-pile test results obtained from the specimens, the optimal manufacturing process was established for the inner and outer cladding tubes of the dual-cooled fuel

  7. High glucose-induced Ca2+ overload and oxidative stress contribute to apoptosis of cardiac cells through mitochondrial dependent and independent pathways.

    Science.gov (United States)

    Kumar, Sandeep; Kain, Vasundhara; Sitasawad, Sandhya L

    2012-07-01

    Cardiac cell apoptosis is the initiating factor of cardiac complications especially diabetic cardiomyopathy. Mitochondria are susceptible to the damaging effects of elevated glucose condition. Calcium overload and oxidative insult are the two mutually non-exclusive phenomena suggested to cause cardiac dysfunction. Here, we examined the effect of high-glucose induced calcium overload in calpain-1 mediated cardiac apoptosis in an in vitro setting. H9c2, rat ventricular myoblast cell line was treated with elevated glucose condition and the cellular consequences were studied. Intracellular calcium trafficking, ROS generation, calpain-1 activation and caspase-12 and caspase-9 pathway were studied using flow cytometry, confocal microscopy and Western blot analysis. High-glucose treatment resulted in increased intracellular calcium ([Ca2+]i) which was mobilized to the mitochondria. Concomitant intra-mitochondrial calcium ([Ca2+]m) increase resulted in enhanced reactive oxygen and nitrogen species generation. These events led to mitochondrial dysfunction and apoptosis. Cardiomyocyte death exhibited several classical markers of apoptosis, including activation of caspases, appearance of annexin V on the outer plasma membrane, increased population of cells with sub-G0/G1 DNA content and nuclear condensation. Key findings include elucidation of cell signaling mechanism of high-glucose induced calcium-dependent cysteine protease calpain-1 activation, which triggers non-conventional caspases as alternate mode of cell death. This information increases the understanding of cardiac cell death under hyperglycemic condition and can possibly be extended for designing new therapeutic strategies for diabetic cardiomyopathy. The novel findings of the study reveal that high glucose induces apoptosis by both mitochondria-dependent and independent pathways via concomitant rise in intracellular calcium. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Macrophage migration inhibitory factor (MIF) knockout preserves cardiac homeostasis through alleviating Akt-mediated myocardial autophagy suppression in high-fat diet-induced obesity.

    Science.gov (United States)

    Xu, X; Ren, J

    2015-03-01

    Macrophage migration inhibitory factor (MIF) has a role in the development of obesity and diabetes. However, whether MIF has a role in fat diet-induced obesity and associated cardiac anomalies still remains unknown. The aim of this study was to examine the impact of MIF knockout on high-fat diet-induced obesity, obesity-associated cardiac anomalies and the underlying mechanisms involved with a focus on Akt-mediated autophagy. Adult male wild-type (WT) and MIF knockout (MIF(-/-)) mice were placed on 45% high-fat diet for 5 months. Oxygen consumption, CO2 production, respiratory exchange ratio, locomotor activity and heat generation were measured using energy calorimeter. Echocardiographic, cardiomyocyte mechanical and intracellular Ca2+ properties were assessed. Apoptosis was examined using terminal dUTP nick end labeling staining and western blot analysis. Akt signaling pathway and autophagy markers were evaluated. Cardiomyocytes isolated from WT and MIF(-/-) mice were treated with recombinant mouse MIF (rmMIF). High-fat diet feeding elicited increased body weight gain, insulin resistance and caloric disturbance in WT and MIF(-/-) mice. High-fat diet induced unfavorable geometric, contractile and histological changes in the heart, the effects of which were alleviated by MIF knockout. In addition, fat diet-induced cardiac anomalies were associated with Akt activation and autophagy suppression, which were nullified by MIF deficiency. In cardiomyocytes from WT mice, autophagy was inhibited by exogenous rmMIF through Akt activation. In addition, MIF knockout rescued palmitic acid-induced suppression of cardiomyocyte autophagy, the effect of which was nullified by rmMIF. These results indicate that MIF knockout preserved obesity-associated cardiac anomalies without affecting fat diet-induced obesity, probably through restoring myocardial autophagy in an Akt-dependent manner. Our findings provide new insights for the role of MIF in obesity and associated cardiac

  9. Cardiac magnetic resonance imaging in patients with chest pain, high troponin levels and absence of coronary artery obstruction

    International Nuclear Information System (INIS)

    Avegliano, G.P.; Costabel, J.P.; Kuschnir, P.; Thierer, J.; Alves de Lima, A.; Sanchez, G.; Ronderos, J.; Huguet, M.; Petit, M.; Frangi, A.A.

    2011-01-01

    The prevalence of myocardial infarction with angiographically normal coronary arteries is approximately 7-10%. The etiological diagnosis is sometimes difficult and is important in terms of clinical practice and prognosis. The goal of our study was to show a series of consecutive patients with an initial diagnosis of acute coronary syndrome with high troponin levels and absence of coronary artery obstruction in which cardiac magnetic resonance imaging (CMRI) gave a description of the myocardial lesion, orientating towards the etiological diagnosis. From January 2005 to December 2009, 720 consecutive patients with an initial diagnosis of acute coronary syndrome and elevated troponins were included; 64 of these patients did not present angiographically significant coronary artery stenosis. Within 72 ± 24 h after coronary angiography, these patients underwent CMRI using b-SSFP sequences for cine imaging in short-axis, 2-, 3- and 4- chamber views for the evaluation of segmental wall motion, with T2-weighted and delayed enhancement (DE) images of the myocardium with an 'inversion-recovery' sequence. The following diagnoses were made: myocarditis (39 patients); myocardial infarction (12 patients); Tako-Tsubo syndrome (8 patients); apical hypertrophic cardiomyopathy (2 patients); 3 patients remained without diagnosis. These findings demonstrate the usefulness of CMRI in the clinical scenario of patients with chest pain, inconclusive ECG findings and high troponin levels with angiographically normal coronary arteries. The presence and distribution pattern of DE make it possible to define the etiological diagnosis and interpret the physiopathological process. (authors) [es

  10. Menhir: An Environment for High Performance Matlab

    Directory of Open Access Journals (Sweden)

    Stéphane Chauveau

    1999-01-01

    Full Text Available In this paper we present Menhir a compiler for generating sequential or parallel code from the Matlab language. The compiler has been designed in the context of using Matlab as a specification language. One of the major features of Menhir is its retargetability to generate parallel and sequential C or Fortran code. We present the compilation process and the target system description for Menhir. Preliminary performances are given and compared with MCC, the MathWorks Matlab compiler.

  11. Inclusion control in high-performance steels

    International Nuclear Information System (INIS)

    Holappa, L.E.K.; Helle, A.S.

    1995-01-01

    Progress of clean steel production, fundamentals of oxide and sulphide inclusions as well as inclusion morphology in normal and calcium treated steels are described. Effects of cleanliness and inclusion control on steel properties are discussed. In many damaging constructional and engineering applications the nonmetallic inclusions have a quite decisive role in steel performance. An example of combination of good mechanical properties and superior machinability by applying inclusion control is presented. (author)

  12. Emerging technologies for high performance infrared detectors

    OpenAIRE

    Tan Chee Leong; Mohseni Hooman

    2018-01-01

    Infrared photodetectors (IRPDs) have become important devices in various applications such as night vision, military missile tracking, medical imaging, industry defect imaging, environmental sensing, and exoplanet exploration. Mature semiconductor technologies such as mercury cadmium telluride and III–V material-based photodetectors have been dominating the industry. However, in the last few decades, significant funding and research has been focused to improve the performance of IRPDs such as...

  13. Development of a high performance liquid chromatography method ...

    African Journals Online (AJOL)

    Development of a high performance liquid chromatography method for simultaneous ... Purpose: To develop and validate a new low-cost high performance liquid chromatography (HPLC) method for ..... Several papers have reported the use of ...

  14. High Performance Home Building Guide for Habitat for Humanity Affiliates

    Energy Technology Data Exchange (ETDEWEB)

    Lindsey Marburger

    2010-10-01

    This guide covers basic principles of high performance Habitat construction, steps to achieving high performance Habitat construction, resources to help improve building practices, materials, etc., and affiliate profiles and recommendations.

  15. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  16. Highly accelerated cardiac cine parallel MRI using low-rank matrix completion and partial separability model

    Science.gov (United States)

    Lyu, Jingyuan; Nakarmi, Ukash; Zhang, Chaoyi; Ying, Leslie

    2016-05-01

    This paper presents a new approach to highly accelerated dynamic parallel MRI using low rank matrix completion, partial separability (PS) model. In data acquisition, k-space data is moderately randomly undersampled at the center kspace navigator locations, but highly undersampled at the outer k-space for each temporal frame. In reconstruction, the navigator data is reconstructed from undersampled data using structured low-rank matrix completion. After all the unacquired navigator data is estimated, the partial separable model is used to obtain partial k-t data. Then the parallel imaging method is used to acquire the entire dynamic image series from highly undersampled data. The proposed method has shown to achieve high quality reconstructions with reduction factors up to 31, and temporal resolution of 29ms, when the conventional PS method fails.

  17. High Performance Computing in Science and Engineering '99 : Transactions of the High Performance Computing Center

    CERN Document Server

    Jäger, Willi

    2000-01-01

    The book contains reports about the most significant projects from science and engineering of the Federal High Performance Computing Center Stuttgart (HLRS). They were carefully selected in a peer-review process and are showcases of an innovative combination of state-of-the-art modeling, novel algorithms and the use of leading-edge parallel computer technology. The projects of HLRS are using supercomputer systems operated jointly by university and industry and therefore a special emphasis has been put on the industrial relevance of results and methods.

  18. High Performance Computing in Science and Engineering '98 : Transactions of the High Performance Computing Center

    CERN Document Server

    Jäger, Willi

    1999-01-01

    The book contains reports about the most significant projects from science and industry that are using the supercomputers of the Federal High Performance Computing Center Stuttgart (HLRS). These projects are from different scientific disciplines, with a focus on engineering, physics and chemistry. They were carefully selected in a peer-review process and are showcases for an innovative combination of state-of-the-art physical modeling, novel algorithms and the use of leading-edge parallel computer technology. As HLRS is in close cooperation with industrial companies, special emphasis has been put on the industrial relevance of results and methods.

  19. Development of High Performance Piezoelectric Polyimides

    Science.gov (United States)

    Simpson, Joycelyn O.; St.Clair, Terry L.; Welch, Sharon S.

    1996-01-01

    In this work a series of polyimides are investigated which exhibit a strong piezoelectric response and polarization stability at temperatures in excess of 100 C. This work was motivated by the need to develop piezoelectric sensors suitable for use in high temperature aerospace applications.

  20. Cardiac Ochronosis

    Science.gov (United States)

    Erek, Ersin; Casselman, Filip P.A.; Vanermen, Hugo

    2004-01-01

    We report the case of 67-year-old woman who underwent aortic valve replacement and mitral valve repair due to ochronotic valvular disease (alkaptonuria), which was diagnosed incidentally during cardiac surgery. PMID:15745303

  1. Cardiac catheterization

    Science.gov (United States)

    ... tests. However, it is very safe when done by an experienced team. The risks include: Cardiac tamponade Heart attack Injury to a coronary artery Irregular heartbeat Low blood pressure Reaction to the contrast dye Stroke Possible complications ...

  2. Powder metallurgical high performance materials. Proceedings. Volume 1: high performance P/M metals

    International Nuclear Information System (INIS)

    Kneringer, G.; Roedhammer, P.; Wildner, H.

    2001-01-01

    The proceedings of this sequence of seminars form an impressive chronicle of the continued progress in the understanding of refractory metals and cemented carbides and in their manufacture and application. There the ingenuity and assiduous work of thousands of scientists and engineers striving for progress in the field of powder metallurgy is documented in more than 2000 contributions covering some 30000 pages. The 15th Plansee Seminar was convened under the general theme 'Powder Metallurgical High Performance Materials'. Under this broadened perspective the seminar will strive to look beyond the refractory metals and cemented carbides, which remain at its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. (author)

  3. Powder metallurgical high performance materials. Proceedings. Volume 1: high performance P/M metals

    Energy Technology Data Exchange (ETDEWEB)

    Kneringer, G; Roedhammer, P; Wildner, H [eds.

    2001-07-01

    The proceedings of this sequence of seminars form an impressive chronicle of the continued progress in the understanding of refractory metals and cemented carbides and in their manufacture and application. There the ingenuity and assiduous work of thousands of scientists and engineers striving for progress in the field of powder metallurgy is documented in more than 2000 contributions covering some 30000 pages. The 15th Plansee Seminar was convened under the general theme 'Powder Metallurgical High Performance Materials'. Under this broadened perspective the seminar will strive to look beyond the refractory metals and cemented carbides, which remain at its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. (author)

  4. High performance flexible electronics for biomedical devices.

    Science.gov (United States)

    Salvatore, Giovanni A; Munzenrieder, Niko; Zysset, Christoph; Kinkeldei, Thomas; Petti, Luisa; Troster, Gerhard

    2014-01-01

    Plastic electronics is soft, deformable and lightweight and it is suitable for the realization of devices which can form an intimate interface with the body, be implanted or integrated into textile for wearable and biomedical applications. Here, we present flexible electronics based on amorphous oxide semiconductors (a-IGZO) whose performance can achieve MHz frequency even when bent around hair. We developed an assembly technique to integrate complex electronic functionalities into textile while preserving the softness of the garment. All this and further developments can open up new opportunities in health monitoring, biotechnology and telemedicine.

  5. High performance image processing of SPRINT

    Energy Technology Data Exchange (ETDEWEB)

    DeGroot, T. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    This talk will describe computed tomography (CT) reconstruction using filtered back-projection on SPRINT parallel computers. CT is a computationally intensive task, typically requiring several minutes to reconstruct a 512x512 image. SPRINT and other parallel computers can be applied to CT reconstruction to reduce computation time from minutes to seconds. SPRINT is a family of massively parallel computers developed at LLNL. SPRINT-2.5 is a 128-node multiprocessor whose performance can exceed twice that of a Cray-Y/MP. SPRINT-3 will be 10 times faster. Described will be the parallel algorithms for filtered back-projection and their execution on SPRINT parallel computers.

  6. High-performance commercial building facades

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor; Selkowitz, Stephen; Bazjanac, Vladimir; Inkarojrit, Vorapat; Kohler, Christian

    2002-06-01

    This study focuses on advanced building facades that use daylighting, sun control, ventilation systems, and dynamic systems. A quick perusal of the leading architectural magazines, or a discussion in most architectural firms today will eventually lead to mention of some of the innovative new buildings that are being constructed with all-glass facades. Most of these buildings are appearing in Europe, although interestingly U.S. A/E firms often have a leading role in their design. This ''emerging technology'' of heavily glazed fagades is often associated with buildings whose design goals include energy efficiency, sustainability, and a ''green'' image. While there are a number of new books on the subject with impressive photos and drawings, there is little critical examination of the actual performance of such buildings, and a generally poor understanding as to whether they achieve their performance goals, or even what those goals might be. Even if the building ''works'' it is often dangerous to take a design solution from one climate and location and transport it to a new one without a good causal understanding of how the systems work. In addition, there is a wide range of existing and emerging glazing and fenestration technologies in use in these buildings, many of which break new ground with respect to innovative structural use of glass. It is unclear as to how well many of these designs would work as currently formulated in California locations dominated by intense sunlight and seismic events. Finally, the costs of these systems are higher than normal facades, but claims of energy and productivity savings are used to justify some of them. Once again these claims, while plausible, are largely unsupported. There have been major advances in glazing and facade technology over the past 30 years and we expect to see continued innovation and product development. It is critical in this process to be able to

  7. Miniaturized high performance sensors for space plasmas

    International Nuclear Information System (INIS)

    Young, D.T.

    1996-01-01

    Operating under ever more constrained budgets, NASA has turned to a new paradigm for instrumentation and mission development in which smaller, faster, better, cheaper is of primary consideration for future space plasma investigations. The author presents several examples showing the influence of this new paradigm on sensor development and discuss certain implications for the scientific return from resource constrained sensors. The author also discusses one way to improve space plasma sensor performance which is to search out new technologies, measurement techniques and instrument analogs from related fields including among others, laboratory plasma physics

  8. High Performance Building Mockup in FLEXLAB

    Energy Technology Data Exchange (ETDEWEB)

    McNeil, Andrew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kohler, Christian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lee, Eleanor S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Selkowitz, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-30

    Genentech has ambitious energy and indoor environmental quality performance goals for Building 35 (B35) being constructed by Webcor at the South San Francisco campus. Genentech and Webcor contracted with the Lawrence Berkeley National Laboratory (LBNL) to test building systems including lighting, lighting controls, shade fabric, and automated shading controls in LBNL’s new FLEXLAB facility. The goal of the testing is to ensure that the systems installed in the new office building will function in a way that reduces energy consumption and provides a comfortable work environment for employees.

  9. High performance computations using dynamical nucleation theory

    International Nuclear Information System (INIS)

    Windus, T L; Crosby, L D; Kathmann, S M

    2008-01-01

    Chemists continue to explore the use of very large computations to perform simulations that describe the molecular level physics of critical challenges in science. In this paper, we describe the Dynamical Nucleation Theory Monte Carlo (DNTMC) model - a model for determining molecular scale nucleation rate constants - and its parallel capabilities. The potential for bottlenecks and the challenges to running on future petascale or larger resources are delineated. A 'master-slave' solution is proposed to scale to the petascale and will be developed in the NWChem software. In addition, mathematical and data analysis challenges are described

  10. Nuclear cardiac

    International Nuclear Information System (INIS)

    Slutsky, R.; Ashburn, W.L.

    1982-01-01

    The relationship between nuclear medicine and cardiology has continued to produce a surfeit of interesting, illuminating, and important reports involving the analysis of cardiac function, perfusion, and metabolism. To simplify the presentation, this review is broken down into three major subheadings: analysis of myocardial perfusion; imaging of the recent myocardial infarction; and the evaluation of myocardial function. There appears to be an increasingly important relationship between cardiology, particularly cardiac physiology, and nuclear imaging techniques

  11. Pressurized planar electrochromatography, high-performance thin-layer chromatography and high-performance liquid chromatography--comparison of performance.

    Science.gov (United States)

    Płocharz, Paweł; Klimek-Turek, Anna; Dzido, Tadeusz H

    2010-07-16

    Kinetic performance, measured by plate height, of High-Performance Thin-Layer Chromatography (HPTLC), High-Performance Liquid Chromatography (HPLC) and Pressurized Planar Electrochromatography (PPEC) was compared for the systems with adsorbent of the HPTLC RP18W plate from Merck as the stationary phase and the mobile phase composed of acetonitrile and buffer solution. The HPLC column was packed with the adsorbent, which was scrapped from the chromatographic plate mentioned. An additional HPLC column was also packed with adsorbent of 5 microm particle diameter, C18 type silica based (LiChrosorb RP-18 from Merck). The dependence of plate height of both HPLC and PPEC separating systems on flow velocity of the mobile phase and on migration distance of the mobile phase in TLC system was presented applying test solute (prednisolone succinate). The highest performance, amongst systems investigated, was obtained for the PPEC system. The separation efficiency of the systems investigated in the paper was additionally confirmed by the separation of test component mixture composed of six hormones. 2010 Elsevier B.V. All rights reserved.

  12. Optical coherence tomography. A new high-resolution imaging technology to study cardiac development in chick embryos

    DEFF Research Database (Denmark)

    Yelbuz, T.M.; Choma, M.A.; Thrane, L.

    2002-01-01

    volumetric reconstructions and short video clips. The OCT-scanned embryos (2 in each group) were photographed after histological sectioning in comparable planes to those visualized by OCT. The optical and histological results showing cardiovascular microstructures such as myocardium, the cardiac jelly......, and endocardium are presented. Conclusions-OCT is a powerful imaging modality which can provide new insight in assessing and understanding normal and abnormal cardiac development in a variety of animal models....

  13. Can Knowledge of the Characteristics of "High Performers" Be Generalised?

    Science.gov (United States)

    McKenna, Stephen

    2002-01-01

    Two managers described as high performing constructed complexity maps of their organization/world. The maps suggested that high performance is socially constructed and negotiated in specific contexts and management competencies associated with it are context specific. Development of high performers thus requires personalized coaching more than…

  14. A high performance totally ordered multicast protocol

    Science.gov (United States)

    Montgomery, Todd; Whetten, Brian; Kaplan, Simon

    1995-01-01

    This paper presents the Reliable Multicast Protocol (RMP). RMP provides a totally ordered, reliable, atomic multicast service on top of an unreliable multicast datagram service such as IP Multicasting. RMP is fully and symmetrically distributed so that no site bears un undue portion of the communication load. RMP provides a wide range of guarantees, from unreliable delivery to totally ordered delivery, to K-resilient, majority resilient, and totally resilient atomic delivery. These QoS guarantees are selectable on a per packet basis. RMP provides many communication options, including virtual synchrony, a publisher/subscriber model of message delivery, an implicit naming service, mutually exclusive handlers for messages, and mutually exclusive locks. It has commonly been held that a large performance penalty must be paid in order to implement total ordering -- RMP discounts this. On SparcStation 10's on a 1250 KB/sec Ethernet, RMP provides totally ordered packet delivery to one destination at 842 KB/sec throughput and with 3.1 ms packet latency. The performance stays roughly constant independent of the number of destinations. For two or more destinations on a LAN, RMP provides higher throughput than any protocol that does not use multicast or broadcast.

  15. High Performance, Three-Dimensional Bilateral Filtering

    International Nuclear Information System (INIS)

    Bethel, E. Wes

    2008-01-01

    Image smoothing is a fundamental operation in computer vision and image processing. This work has two main thrusts: (1) implementation of a bilateral filter suitable for use in smoothing, or denoising, 3D volumetric data; (2) implementation of the 3D bilateral filter in three different parallelization models, along with parallel performance studies on two modern HPC architectures. Our bilateral filter formulation is based upon the work of Tomasi [11], but extended to 3D for use on volumetric data. Our three parallel implementations use POSIX threads, the Message Passing Interface (MPI), and Unified Parallel C (UPC), a Partitioned Global Address Space (PGAS) language. Our parallel performance studies, which were conducted on a Cray XT4 supercomputer and aquad-socket, quad-core Opteron workstation, show our algorithm to have near-perfect scalability up to 120 processors. Parallel algorithms, such as the one we present here, will have an increasingly important role for use in production visual analysis systems as the underlying computational platforms transition from single- to multi-core architectures in the future.

  16. High-performance sport, marijuana, and cannabimimetics.

    Science.gov (United States)

    Hilderbrand, Richard L

    2011-11-01

    The prohibition on use of cannabinoids in sporting competitions has been widely debated and continues to be a contentious issue. Information continues to accumulate on the adverse health effects of smoked marijuana and the decrement of performance caused by the use of cannabinoids. The objective of this article is to provide an overview of cannabinoids and cannabimimetics that directly or indirectly impact sport, the rules of sport, and performance of the athlete. This article reviews some of the history of marijuana in Olympic and Collegiate sport, summarizes the guidelines by which a substance is added to the World Anti-Doping Agency Prohibited List, and updates information on the pharmacologic effects of cannabinoids and their mechanism of action. The recently marketed cannabimimetics Spice and K2 are included in the discussion as they activate the same receptors as are activated by THC. The article also provides a view as to why the World Anti-Doping Agency prohibits cannabinoid or cannabimimetic use incompetition and should continue to do so.

  17. High Performance, Three-Dimensional Bilateral Filtering

    Energy Technology Data Exchange (ETDEWEB)

    Bethel, E. Wes

    2008-06-05

    Image smoothing is a fundamental operation in computer vision and image processing. This work has two main thrusts: (1) implementation of a bilateral filter suitable for use in smoothing, or denoising, 3D volumetric data; (2) implementation of the 3D bilateral filter in three different parallelization models, along with parallel performance studies on two modern HPC architectures. Our bilateral filter formulation is based upon the work of Tomasi [11], but extended to 3D for use on volumetric data. Our three parallel implementations use POSIX threads, the Message Passing Interface (MPI), and Unified Parallel C (UPC), a Partitioned Global Address Space (PGAS) language. Our parallel performance studies, which were conducted on a Cray XT4 supercomputer and aquad-socket, quad-core Opteron workstation, show our algorithm to have near-perfect scalability up to 120 processors. Parallel algorithms, such as the one we present here, will have an increasingly important role for use in production visual analysis systems as the underlying computational platforms transition from single- to multi-core architectures in the future.

  18. HIGH PERFORMANCE PHOTOGRAMMETRIC PROCESSING ON COMPUTER CLUSTERS

    Directory of Open Access Journals (Sweden)

    V. N. Adrov

    2012-07-01

    Full Text Available Most cpu consuming tasks in photogrammetric processing can be done in parallel. The algorithms take independent bits as input and produce independent bits as output. The independence of bits comes from the nature of such algorithms since images, stereopairs or small image blocks parts can be processed independently. Many photogrammetric algorithms are fully automatic and do not require human interference. Photogrammetric workstations can perform tie points measurements, DTM calculations, orthophoto construction, mosaicing and many other service operations in parallel using distributed calculations. Distributed calculations save time reducing several days calculations to several hours calculations. Modern trends in computer technology show the increase of cpu cores in workstations, speed increase in local networks, and as a result dropping the price of the supercomputers or computer clusters that can contain hundreds or even thousands of computing nodes. Common distributed processing in DPW is usually targeted for interactive work with a limited number of cpu cores and is not optimized for centralized administration. The bottleneck of common distributed computing in photogrammetry can be in the limited lan throughput and storage performance, since the processing of huge amounts of large raster images is needed.

  19. Australia's new high performance research reactor

    International Nuclear Information System (INIS)

    Miller, R.; Abbate, P.M.

    2003-01-01

    A contract for the design and construction of the Replacement Research Reactor was signed in July 2000 between ANSTO and INVAP from Argentina. Since then the detailed design has been completed, a construction authorization has been obtained, and construction has commenced. The reactor design embodies modern safety thinking together with innovative solutions to ensure a highly safe and reliable plant. Also significant effort has been placed on providing the facility with diverse and ample facilities to maximize its use for irradiating material for radioisotope production as well as providing high neutron fluxes for neutron beam research. The project management organization and planing is commensurate with the complexity of the project and the number of players involved. (author)

  20. High Performance Single Nanowire Tunnel Diodes

    DEFF Research Database (Denmark)

    Wallentin, Jesper; Persson, Johan Mikael; Wagner, Jakob Birkedal

    NWs were contacted in a NW-FET setup. Electrical measurements at room temperature display typical tunnel diode behavior, with a Peak-to-Valley Current Ratio (PVCR) as high as 8.2 and a peak current density as high as 329 A/cm2. Low temperature measurements show improved PVCR of up to 27.6....... is the tunnel (Esaki) diode, which provides a low-resistance connection between junctions. We demonstrate an InP-GaAs NW axial heterostructure with tunnel diode behavior. InP and GaAs can be readily n- and p-doped, respectively, and the heterointerface is expected to have an advantageous type II band alignment...

  1. Future Vehicle Technologies : high performance transportation innovations

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, T. [Future Vehicle Technologies Inc., Maple Ridge, BC (Canada)

    2010-07-01

    Battery management systems (BMS) were discussed in this presentation, with particular reference to the basic BMS design considerations; safety; undisclosed information about BMS; the essence of BMS; and Future Vehicle Technologies' BMS solution. Basic BMS design considerations that were presented included the balancing methodology; prismatic/cylindrical cells; cell protection; accuracy; PCB design, size and components; communications protocol; cost of manufacture; and expandability. In terms of safety, the presentation addressed lithium fires; high voltage; high voltage ground detection; crash/rollover shutdown; complete pack shutdown capability; and heat shields, casings, and impact protection. BMS bus bar engineering considerations were discussed along with good chip design. It was concluded that FVTs advantage is a unique skillset in automotive technology and the development of speed and cost effectiveness. tabs., figs.

  2. Radiation cured coatings for high performance products

    International Nuclear Information System (INIS)

    Parkins, J.C.; Teesdale, D.H.

    1984-01-01

    Development over the past ten years of radiation curable coating and lacquer systems and the means of curing them has led to new products in the packaging, flooring, furniture and other industries. Solventless lacquer systems formulated with acrylates and other resins enable high levels of durability, scuff resistance and gloss to be achieved. Ultra violet and electron beam radiation curing are used, the choice depending on the nature of the coating, the product and the scale of the operation. (author)

  3. High thermoelectric performance of graphite nanofibers

    OpenAIRE

    Tran, Van-Truong; Saint-Martin, Jérôme; Dollfus, Philippe; Volz, Sebastian

    2017-01-01

    Graphite nanofibers (GNFs) have been demonstrated to be a promising material for hydrogen storage and heat management in electronic devices. Here, by means of first-principles and transport simulations, we show that GNFs can also be an excellent material for thermoelectric applications thanks to the interlayer weak van der Waals interaction that induces low thermal conductance and a step-like shape in the electronic transmission with mini-gaps, which are necessary ingredients to achieve high ...

  4. New monomers for high performance polymers

    Science.gov (United States)

    Gratz, Roy F.

    1993-01-01

    This laboratory has been concerned with the development of new polymeric materials with high thermo-oxidative stability for use in the aerospace and electronics industries. Currently, there is special emphasis on developing matrix resins and composites for the high speed civil transport (HSCT) program. This application requires polymers that have service lifetimes of 60,000 hr at 350 F (177 C) and that are readily processible into void-free composites, preferably by melt-flow or powder techniques that avoid the use of high boiling solvents. Recent work has focused on copolymers which have thermally stable imide groups separated by flexible arylene ether linkages, some with trifluoromethyl groups attached to the aromatic rings. The presence of trifluoromethyl groups in monomers and polymers often improves their solubility and processibility. The goal of this research was to synthesize several new monomers containing pendant trifluoromethyl groups and to incorporate these monomers into new imide/arylene ether copolymers. Initially, work was begun on the synthesis of three target compounds. The first two, 3,5-dihydroxybenzo trifluoride and 3-amino 5-hydroxybenzo trifluoride, are intermediates in the synthesis of more complex monomers. The third, 3,5-bis (3-amino-phenoxy) benzotrifluoride, is an interesting diamine that could be incorporated into a polyimide directly.

  5. High performance repairing of reinforced concrete structures

    International Nuclear Information System (INIS)

    Iskhakov, I.; Ribakov, Y.; Holschemacher, K.; Mueller, T.

    2013-01-01

    Highlights: ► Steel fibered high strength concrete is effective for repairing concrete elements. ► Changing fibers’ content, required ductility of the repaired element is achieved. ► Experiments prove previously developed design concepts for two layer beams. -- Abstract: Steel fibered high strength concrete (SFHSC) is an effective material that can be used for repairing concrete elements. Design of normal strength concrete (NSC) elements that should be repaired using SFHSC can be based on general concepts for design of two-layer beams, consisting of SFHSC in the compressed zone and NSC without fibers in the tensile zone. It was previously reported that such elements are effective when their section carries rather large bending moments. Steel fibers, added to high strength concrete, increase its ultimate deformations due to the additional energy dissipation potential contributed by fibers. When changing the fibers’ content, a required ductility level of the repaired element can be achieved. Providing proper ductility is important for design of structures to dynamic loadings. The current study discusses experimental results that form a basis for finding optimal fiber content, yielding the highest Poisson coefficient and ductility of the repaired elements’ sections. Some technological issues as well as distribution of fibers in the cross section of two-layer bending elements are investigated. The experimental results, obtained in the frame of this study, form a basis for general technological provisions, related to repairing of NSC beams and slabs, using SFHSC.

  6. Effect of autogenic training on cardiac autonomic nervous activity in high-risk fire service workers for posttraumatic stress disorder.

    Science.gov (United States)

    Mitani, Satoko; Fujita, Masatoshi; Sakamoto, Satoko; Shirakawa, Taro

    2006-05-01

    We investigated the effect of autogenic training (AT) on cardiac autonomic nervous activity in fire services workers with the use of the questionnaire of the Japanese-language version of Impact of Event Scale-Revised (IES-R-J) and indexes of heart rate variability. We studied 22 male fire services workers who were divided into posttraumatic stress disorder (PTSD)-related stress group (n=10) and control group (n=12). They underwent AT twice or three times a week for 2 months. Posttraumatic stress disorder-related stress group showed a significantly higher cardiac sympathetic nervous activity and a significantly lower cardiac parasympathetic nervous activity than control group at baseline. Autogenic training significantly decreased cardiac sympathetic nervous activity and significantly increased cardiac parasympathetic nervous activity in both groups. These changes were accompanied by a significant decrease in the total points of IES-R-J. Autogenic training is effective for ameliorating the disturbance of cardiac autonomic nervous activity and psychological issues secondary to PTSD.

  7. Ultrasound-guided transversus abdominis plane block in combination with ilioinguinal-iliohypogastric block in a high risk cardiac patient for inguinal hernia repair: a case report

    OpenAIRE

    BARISIN, STJEPAN; DUZEL, VIKTOR; SAKIC, LIVIJA

    2015-01-01

    Background and Purpose: A high risk cardiac patient, ASA IV, was planned for inguinal hernia repair. Since general anaesthesia presented a high risk, anaesthesia was conducted with a transversus abdominis plane (TAP) in combination with ilioinguinal-iliohypogastric (ILIH) block. Material and Methods: A 70-year old male patient with severe CAD and previous LAD PTCA, AVR, in situ PPM and severe MR and TR 3+, was planned for elective inguinal hernia repair. The preoperative ECH...

  8. Information processing among high-performance managers

    Directory of Open Access Journals (Sweden)

    S.C. Garcia-Santos

    2010-01-01

    Full Text Available The purpose of this study was to evaluate the information processing of 43 business managers with a professional superior performance. The theoretical framework considers three models: the Theory of Managerial Roles of Henry Mintzberg, the Theory of Information Processing, and Process Model Response to Rorschach by John Exner. The participants have been evaluated by Rorschach method. The results show that these managers are able to collect data, evaluate them and establish rankings properly. At same time, they are capable of being objective and accurate in the problems assessment. This information processing style permits an interpretation of the world around on basis of a very personal and characteristic processing way or cognitive style.

  9. High temperature performance of polymer composites

    CERN Document Server

    Keller, Thomas

    2014-01-01

    The authors explain the changes in the thermophysical and thermomechanical properties of polymer composites under elevated temperatures and fire conditions. Using microscale physical and chemical concepts they allow researchers to find reliable solutions to their engineering needs on the macroscale. In a unique combination of experimental results and quantitative models, a framework is developed to realistically predict the behavior of a variety of polymer composite materials over a wide range of thermal and mechanical loads. In addition, the authors treat extreme fire scenarios up to more than 1000°C for two hours, presenting heat-protection methods to improve the fire resistance of composite materials and full-scale structural members, and discuss their performance after fire exposure. Thanks to the microscopic approach, the developed models are valid for a variety of polymer composites and structural members, making this work applicable to a wide audience, including materials scientists, polymer chemist...

  10. High performance concrete with blended cement

    International Nuclear Information System (INIS)

    Biswas, P.P.; Saraswati, S.; Basu, P.C.

    2012-01-01

    Principal objectives of the proposed project are two folds. Firstly, to develop the HPC mix suitable to NPP structures with blended cement, and secondly to study its durability necessary for desired long-term performance. Three grades of concrete to b considered in the proposed projects are M35, M50 and M60 with two types of blended cements, i.e. Portland slag cement (PSC) and Portland pozzolana cement (PPC). Three types of mineral admixtures - silica fume, fly ash and ground granulated blast furnace slag will be used. Concrete mixes with OPc and without any mineral admixture will be considered as reference case. Durability study of these mixes will be carried out

  11. High performance VLSI telemetry data systems

    Science.gov (United States)

    Chesney, J.; Speciale, N.; Horner, W.; Sabia, S.

    1990-01-01

    NASA's deployment of major space complexes such as Space Station Freedom (SSF) and the Earth Observing System (EOS) will demand increased functionality and performance from ground based telemetry acquisition systems well above current system capabilities. Adaptation of space telemetry data transport and processing standards such as those specified by the Consultative Committee for Space Data Systems (CCSDS) standards and those required for commercial ground distribution of telemetry data, will drive these functional and performance requirements. In addition, budget limitations will force the requirement for higher modularity, flexibility, and interchangeability at lower cost in new ground telemetry data system elements. At NASA's Goddard Space Flight Center (GSFC), the design and development of generic ground telemetry data system elements, over the last five years, has resulted in significant solutions to these problems. This solution, referred to as the functional components approach includes both hardware and software components ready for end user application. The hardware functional components consist of modern data flow architectures utilizing Application Specific Integrated Circuits (ASIC's) developed specifically to support NASA's telemetry data systems needs and designed to meet a range of data rate requirements up to 300 Mbps. Real-time operating system software components support both embedded local software intelligence, and overall system control, status, processing, and interface requirements. These components, hardware and software, form the superstructure upon which project specific elements are added to complete a telemetry ground data system installation. This paper describes the functional components approach, some specific component examples, and a project example of the evolution from VLSI component, to basic board level functional component, to integrated telemetry data system.

  12. High Performance Fuel Technology Development(I)

    International Nuclear Information System (INIS)

    Song, Kun Woo; Kim, Keon Sik; Bang, Jeong Yong; Park, Je Keon; Chen, Tae Hyun; Kim, Hyung Kyu

    2010-04-01

    The dual-cooled annular fuel has been investigated for the purpose of achieving the power uprate of 20% and decreasing pellet temperature by 30%. The 12x12 rod array and basic design was developed, which is mechanically compatible with the OPR-1000. The reactor core analysis has been performed using this design, and the results have shown that the criteria of nuclear, thermohydraulic and safety design are satisfied and pellet temperature can be lowered by 40% even in 120% power. The basic design of fuel component was developed and the cladding thickness was designed through analysis and experiments. The solutions have been proposed and analyzed to the technical issues such as 'inner channel blockage' and 'imbalance between inner and outer coolant'. The annular pellet was fabricated with good control of shape and size, and especially, a new sintering technique has been developed to control the deviation of inner diameter within ±5μm. The irradiation test of annular pellets has been conducted up to 10 MWD/kgU to find out the densification and swelling behaviors. The 11 types of materials candidates have developed for the PCI-endurance pellet, and the material containing the Mn-Al additive showed its creep performance of much better than UO2 material. The HANA cladding has been irradiated up to 61 MWD/kgU, and the results have shown that its oxidation resistance is better by 40% than that of Zircaloy. The 30 types of candidate materials for next generation have been developed through alloy design and property tests

  13. Entrance radiation doses during paediatric cardiac catheterizations performed for diagnosis or the treatment of congenital heart disease

    International Nuclear Information System (INIS)

    Papadopoulou, D.; Yakoumakis, Em; Sandilos, P.; Thanopoulos, V.; Makri, Tr; Gialousis, G.; Houndas, D.; Yakoumakis, N.; Georgiou, Ev

    2005-01-01

    The purpose of this study was to estimate the radiation exposure of children, during cardiac catheterizations for the diagnosis or treatment of congenital heart disease. Radiation doses were estimated for 45 children aged from 1 d to 13 y old. Thermoluminescent dosemeters (TLDs) were used to estimate the posterior entrance dose (D P ), the lateral entrance dose (D LAT ), the thyroid dose and the gonads dose. A dose-area product (DAP) meter was also attached externally to the tube of the angiographic system and gave a direct value in mGy cm 2 for each procedure. Posterior and lateral entrance dose values during cardiac catheterizations ranged from 1 to 197 mGy and from 1.1 to 250.3 mGy, respectively. Radiation exposure to the thyroid and the gonads ranged from 0.3 to 8.4 mGy to 0.1 and 0.7 mGy, respectively. Finally, the DAP meter values ranged between 360 and 33,200 mGy cm 2 . Radiation doses measured in this study are comparable with those reported to previous studies. Moreover, strong correlation was found between the DAP values and the entrance radiation dose measured with TLDs. (authors)

  14. Major depressive disorder, anxiety disorders, and cardiac biomarkers in subjects at high risk of obstructive sleep apnea.

    Science.gov (United States)

    Einvik, Gunnar; Hrubos-Strøm, Harald; Randby, Anna; Nordhus, Inger Hilde; Somers, Virend K; Omland, Torbjørn; Dammen, Toril

    2011-06-01

    Cardiac biomarkers may be valuable when exploring potential mechanisms for the association between cardiovascular disease and psychiatric disorders. In subjects at increased risk for obstructive sleep apnea, we examined whether major depressive disorder (MDD), anxiety disorders, or the combination of these was associated with circulating C-reactive protein (CRP), cardiac troponin T (cTnT), or heart rate variability (HRV). From the Akershus Sleep Apnea Project, 290 participants were assessed for MDD or any anxiety disorder by a physician using the Structured Clinical Interview for DSM-IV. Fasting blood samples were analyzed with high-sensitivity assays for CRP, cTnT, and HRV calculated from a Holter recording. Age, sex, hypertension, diabetes, hyperlipidemia, obesity, smoking, apnea-hypopnea index, and previous cardiovascular disease were adjusted for. The CRP levels (median [interquartile range], mg/L) were higher in depressive (2.7 [1.1-5.8]) versus nondepressive (1.3 [0.7-3.1], p = .02) and in anxious (2.8 [0.9-5.2]) versus nonanxious (1.3 [0.7-3.1], p = .01). MDD was independently associated with CRP (unstandardized β = 0.387, p = .04), but anxiety was not (unstandardized β = 0.298, p = .09). The CRP level was highest in subjects with comorbid MDD and anxiety (3.4 [1.1-7.8]). The unadjusted and adjusted odds ratios (95% confidence interval) for having measurable cTnT (> 3 ng/L) were 0.49 (0.24-1.07) and 0.92 (0.31-2.67) for MDD versus nondepressive and 0.38 (0.18-0.80) and 0.61 (0.30-2.05) for anxiety versus nonanxiety, respectively. HRV did not vary between groups. Although CRP was increased both in MDD and anxiety disorders, patients with comorbid MDD and anxiety may be particularly prone to increased systemic inflammation. Neither MDD nor anxiety disorders were associated with low-level myocardial damage or HRV.

  15. High-frequency autonomic modulation: a new model for analysis of autonomic cardiac control.

    Science.gov (United States)

    Champéroux, Pascal; Fesler, Pierre; Judé, Sebastien; Richard, Serge; Le Guennec, Jean-Yves; Thireau, Jérôme

    2018-05-03

    Increase in high-frequency beat-to-beat heart rate oscillations by torsadogenic hERG blockers appears to be associated with signs of parasympathetic and sympathetic co-activation which cannot be assessed directly using classic methods of heart rate variability analysis. The present work aimed to find a translational model that would allow this particular state of the autonomic control of heart rate to be assessed. High-frequency heart rate and heart period oscillations were analysed within discrete 10 s intervals in a cohort of 200 healthy human subjects. Results were compared to data collected in non-human primates and beagle dogs during pharmacological challenges and torsadogenic hERG blockers exposure, in 127 genotyped LQT1 patients on/off β-blocker treatment and in subgroups of smoking and non-smoking subjects. Three states of autonomic modulation, S1 (parasympathetic predominance) to S3 (reciprocal parasympathetic withdrawal/sympathetic activation), were differentiated to build a new model of heart rate variability referred to as high-frequency autonomic modulation. The S2 state corresponded to a specific state during which both parasympathetic and sympathetic systems were coexisting or co-activated. S2 oscillations were proportionally increased by torsadogenic hERG-blocking drugs, whereas smoking caused an increase in S3 oscillations. The combined analysis of the magnitude of high-frequency heart rate and high-frequency heart period oscillations allows a refined assessment of heart rate autonomic modulation applicable to long-term ECG recordings and offers new approaches to assessment of the risk of sudden death both in terms of underlying mechanisms and sensitivity. © 2018 The Authors. British Journal of Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.

  16. Carbon nanotubes for high-performance logic

    OpenAIRE

    Chen, Zhihong; Wong, H.S. Phillip; Mitra, Subhasish; Bol, Aggeth; Peng, Lianmao; Hills, Gage; Thissen, Nick

    2014-01-01

    Single-wall carbon nanotubes (CNTs) were discovered in 1993 and have been an area of intense research since then. They offer the right dimensions to explore material science and physical chemistry at the nanoscale and are the perfect system to study low-dimensional physics and transport. In the past decade, more attention has been shifted toward making use of this unique nanomaterial in real-world applications. In this article, we focus on potential applications of CNTs in the high-performanc...

  17. Environmentally friendly, high-performance generation

    International Nuclear Information System (INIS)

    Kalmari, A.

    2003-01-01

    The project developer, owner, and operator of the new 45 MWth BFB-based cogeneration plant in Iisalmi is Termia Oy, part of the Atro Group (formerly Savon Voima Oy). Fired on peat and wood waste and handed over to the customer in November 2002, the plant's electrical output is sold to the parent company and heat locally to customers in Iisalmi. When the construction decision was made, one of the main objectives was to utilise as high a level of indigenous fuels (peat and biomass) as possible, at a high level of efficiency. An environmental impact analysis was carried out, taking into account the impact of various fuels and emissions in terms of combustion and logistics. One main benefit of the type of plant ultimately selected was that the bulk of the fuel can be supplied from the surrounding area. This is very important in terms of fuel supply security and local employment. The government provided a EUR 2.7 million grant for the project, equivalent to 13% of the total EUR 21 million investment budget. Before the plant was built, Termia used approximately 95 GWh of indigenous fuels annually. Today, this figure is 220 GWh. The main fuel used is milled peat. Up to 30% green chips from logging residues can be used. Recycled waste fuel can cover up to 3% of the total fuel requirement

  18. Liquid Argon Calorimeter performance at High Rates

    CERN Document Server

    Seifert, F; The ATLAS collaboration

    2013-01-01

    The expected increase of luminosity at HL-LHC by a factor of ten with respect to LHC luminosities has serious consequences for the signal reconstruction, radiation hardness requirements and operations of the ATLAS liquid argon calorimeters in the endcap, respectively forward region. Small modules of each type of calorimeter have been built and exposed to a high intensity proton beam of 50 GeV at IHEP/Protvino. The beam is extracted via the bent crystal technique, offering the unique opportunity to cover intensities ranging from $10^6$ p/s up to $3\\cdot10^{11}$ p/s. This exceeds the deposited energy per time expected at HL-LHC by more than a factor of 100. The correlation between beam intensity and the read-out signal has been studied. The data show clear indications of pulse shape distortion due to the high ionization build-up, in agreement with MC expectations. This is also confirmed from the dependence of the HV currents on beam intensity.

  19. High-performance silicon nanowire bipolar phototransistors

    Science.gov (United States)

    Tan, Siew Li; Zhao, Xingyan; Chen, Kaixiang; Crozier, Kenneth B.; Dan, Yaping

    2016-07-01

    Silicon nanowires (SiNWs) have emerged as sensitive absorbing materials for photodetection at wavelengths ranging from ultraviolet (UV) to the near infrared. Most of the reports on SiNW photodetectors are based on photoconductor, photodiode, or field-effect transistor device structures. These SiNW devices each have their own advantages and trade-offs in optical gain, response time, operating voltage, and dark current noise. Here, we report on the experimental realization of single SiNW bipolar phototransistors on silicon-on-insulator substrates. Our SiNW devices are based on bipolar transistor structures with an optically injected base region and are fabricated using CMOS-compatible processes. The experimentally measured optoelectronic characteristics of the SiNW phototransistors are in good agreement with simulation results. The SiNW phototransistors exhibit significantly enhanced response to UV and visible light, compared with typical Si p-i-n photodiodes. The near infrared responsivities of the SiNW phototransistors are comparable to those of Si avalanche photodiodes but are achieved at much lower operating voltages. Compared with other reported SiNW photodetectors as well as conventional bulk Si photodiodes and phototransistors, the SiNW phototransistors in this work demonstrate the combined advantages of high gain, high photoresponse, low dark current, and low operating voltage.

  20. Effect of High Intensity Interval Training on Cardiac Function in Children with Obesity: A Randomised Controlled Trial.

    Science.gov (United States)

    Ingul, Charlotte B; Dias, Katrin A; Tjonna, Arnt E; Follestad, Turid; Hosseini, Mansoureh S; Timilsina, Anita S; Hollekim-Strand, Siri M; Ro, Torstein B; Davies, Peter S W; Cain, Peter A; Leong, Gary M; Coombes, Jeff S

    2018-02-13

    High intensity interval training (HIIT) confers superior cardiovascular health benefits to moderate intensity continuous training (MICT) in adults and may be efficacious for improving diminished cardiac function in obese children. The aim of this study was to compare the effects of HIIT, MICT and nutrition advice interventions on resting left ventricular (LV) peak systolic tissue velocity (S') in obese children. Ninety-nine obese children were randomised into one of three 12-week interventions, 1) HIIT [n = 33, 4 × 4 min bouts at 85-95% maximum heart rate (HR max ), 3 times/week] and nutrition advice, 2) MICT [n = 32, 44 min at 60-70% HR max , 3 times/week] and nutrition advice, and 3) nutrition advice only (nutrition) [n = 34]. Twelve weeks of HIIT and MICT were equally efficacious, but superior to nutrition, for normalising resting LV S' in children with obesity (estimated mean difference 1.0 cm/s, 95% confidence interval 0.5 to 1.6 cm/s, P HIIT and MICT were superior to nutrition advice only for improving resting LV systolic function in obese children. Copyright © 2017 Elsevier Inc. All rights reserved.