WorldWideScience

Sample records for high backscatter intensity

  1. Stimulated Raman backscattering at high laser intensities

    Energy Technology Data Exchange (ETDEWEB)

    Skoric, M.M. [Vinca Inst. of Nuclear Sciences, Belgrade (Yugoslavia); Tajima, Toshiki; Sasaki, Akira; Maluckov, A.; Jovanovic, M.

    1998-03-01

    Signatures of Stimulated Raman backscattering of a short-pulse high-intensity laser interacting with an underdense plasma are discussed. We introduce a nonlinear three-wave interaction model that accounts for laser pump depletion and relativistic detuning. A mechanism is revealed based on a generic route to chaos, that predicts a progressive increase of the backscatter complexity with a growing laser intensity. Importance of kinetic effects is outlined and demonstrated in fluid-hybrid and particle simulations. As an application, we show that spectral anomalies of the backscatter, predicted by the above model, are consistent with recent sub-picosecond, high-intensity laser gas-target measurements at Livermore and elsewhere. Finally, a recently proposed scheme for generation of ultra-short, low-prepulse laser pulses by Raman backscattering in a thin foil target, is shown. (author)

  2. Displacement analysis of diagnostic ultrasound backscatter: A methodology for characterizing, modeling, and monitoring high intensity focused ultrasound therapy

    OpenAIRE

    2010-01-01

    Accurate monitoring of high intensity focused ultrasound (HIFU) therapy is critical for widespread clinical use. Pulse-echo diagnostic ultrasound (DU) is known to exhibit temperature sensitivity through relative changes in time-of-flight between two sets of radio frequency (RF) backscatter measurements, one acquired before and one after therapy. These relative displacements, combined with knowledge of the exposure protocol, material properties, heat transfer, and measurement noise statistics,...

  3. Calibration of ultrasound backscatter temperature imaging for high-intensity focused ultrasound treatment planning.

    Science.gov (United States)

    Civale, John; Rivens, Ian; Ter Haar, Gail; Morris, Hugh; Coussios, Constantin; Friend, Peter; Bamber, Jeffrey

    2013-09-01

    High-intensity focused ultrasound (HIFU) is rapidly gaining acceptance as a non-invasive method for soft tissue tumor ablation, but improvements in the methods of treatment delivery, planning and monitoring are still required. Backscatter temperature imaging (BTI) uses ultrasound to visualize heating-induced echo strain and may be used to indicate the position of the HIFU focal region using low-power "sub-lesioning" exposure. The technique may also provide a quantitative tool for assessing the efficacy of treatment delivery if apparent strain measurements can be related to the underlying temperature rise. To obtain temperature estimates from strain measurements, the relationship between these variables has to be either measured or otherwise assumed from previous calibrations in similar tissues. This article describes experimental measurements aimed at deriving the relationship between temperature rise and apparent strain in the laboratory environment using both ex vivo bovine liver tissue samples and normothermically perfused porcine livers. A BTI algorithm was applied to radiofrequency ultrasound echo data acquired from a clinical ultrasound scanner (Z.One, Zonare Medical Systems, Mountain View, CA, USA) where the imaging probe was aligned with the focal region of a HIFU transducer. Temperature measurements were obtained using needle thermocouples implanted in the liver tissue. A series of "non-ablative" HIFU exposures giving peak temperatures below 10°C were made in three separate ex vivo bovine livers, yielding an average strain/temperature coefficient of 0.126 ± 0.088 percentage strain per degree Celsius. In the perfused porcine livers at a starting temperature of 38°C (normal body temperature) the strain/temperature coefficients were found to be 0.040 ± 0.029 percentage strain per degree Celsius. The uncertainty in these results is directly linked to the precision of the strain measurement, as well as the naturally occurring variance between different

  4. Processing ultrasound backscatter to monitor high-intensity focused ultrasound (HIFU) therapy

    Science.gov (United States)

    Kaczkowski, Peter J.; Anand, Ajay; Bailey, Michael R.

    2005-09-01

    The development of new noninvasive surgical methods such as HIFU for the treatment of cancer and internal bleeding requires simultaneous development of new sensing approaches to guide, monitor, and assess the therapy. Ultrasound imaging using echo amplitude has long been used to map tissue morphology for diagnostic interpretation by the clinician. New quantitative ultrasonic methods that rely on amplitude and phase processing for tissue characterization are being developed for monitoring of ablative therapy. We have been developing the use of full wave ultrasound backscattering for real-time temperature estimation, and to image changes in tissue backscatter spectrum as therapy progresses. Both approaches rely on differential processing of the backscatter signal in time, and precise measurement of phase differences. Noise and artifacts from motion and nonstationary speckle statistics are addressed by constraining inversions for tissue parameters with physical models. We present results of HIFU experiments with static point and scanned HIFU exposures in which temperature rise can be accurately mapped using a new heat transfer equation (HTE) model-constrained inverse approach. We also present results of a recently developed spectral imaging method that elucidates microbubble-mediated nonlinearity not visible as a change in backscatter amplitude. [Work supported by Army MRMC.

  5. Averaging of Backscatter Intensities in Compounds

    Science.gov (United States)

    Donovan, John J.; Pingitore, Nicholas E.; Westphal, Andrew J.

    2002-01-01

    Low uncertainty measurements on pure element stable isotope pairs demonstrate that mass has no influence on the backscattering of electrons at typical electron microprobe energies. The traditional prediction of average backscatter intensities in compounds using elemental mass fractions is improperly grounded in mass and thus has no physical basis. We propose an alternative model to mass fraction averaging, based of the number of electrons or protons, termed “electron fraction,” which predicts backscatter yield better than mass fraction averaging. PMID:27446752

  6. Displacement analysis of diagnostic ultrasound backscatter: a methodology for characterizing, modeling, and monitoring high intensity focused ultrasound therapy.

    Science.gov (United States)

    Speyer, Gavriel; Kaczkowski, Peter J; Brayman, Andrew A; Crum, Lawrence A

    2010-07-01

    Accurate monitoring of high intensity focused ultrasound (HIFU) therapy is critical for widespread clinical use. Pulse-echo diagnostic ultrasound (DU) is known to exhibit temperature sensitivity through relative changes in time-of-flight between two sets of radio frequency (RF) backscatter measurements, one acquired before and one after therapy. These relative displacements, combined with knowledge of the exposure protocol, material properties, heat transfer, and measurement noise statistics, provide a natural framework for estimating the administered heating, and thereby therapy. The proposed method, termed displacement analysis, identifies the relative displacements using linearly independent displacement patterns, or modes, each induced by a particular time-varying heating applied during the exposure interval. These heating modes are themselves linearly independent. This relationship implies that a linear combination of displacement modes aligning the DU measurements is the response to an identical linear combination of heating modes, providing the heating estimate. Furthermore, the accuracy of coefficient estimates in this approximation is determined a priori, characterizing heating, thermal dose, and temperature estimates for any given protocol. Predicted performance is validated using simulations and experiments in alginate gel phantoms. Evidence for a spatially distributed interaction between temperature and time-of-flight changes is presented.

  7. The use of multibeam backscatter intensity data as a tool for mapping glacial deposits in the Central North Sea, UK

    Science.gov (United States)

    Stewart, Heather; Bradwell, Tom

    2014-05-01

    Multibeam backscatter intensity data acquired offshore eastern Scotland and north-eastern England have been used to map drumlin fields, large arcuate moraine ridges, smaller scale moraine ridges, and incised channels on the sea floor. The study area includes the catchments of the previously proposed, but only partly mapped, Strathmore, Forth-Tay, and Tweed palaeo-ice streams. The ice sheet glacial landsystem is extremely well preserved on the sea bed and comprehensive mapping of the seafloor geomorphology has been undertaken. The authors demonstrate the value in utilising not only digital terrain models (both NEXTMap and multibeam bathymetry derived) in undertaking geomorphological mapping, but also examining the backscatter intensity data that is often overlooked. Backscatter intensity maps were generated using FM Geocoder by the British Geological Survey. FM Geocoder corrects the backscatter intensities registered by the multibeam echosounder system, and then geometrically corrects and positions each acoustic sample in a backscatter mosaic. The backscatter intensity data were gridded at the best resolution per dataset (between 2 and 5 m). The strength of the backscattering is dependent upon sediment type, grain size, survey conditions, sea-bed roughness, compaction and slope. A combination of manual interpretation and semi-automated classification of the backscatter intensity data (a predictive method for mapping variations in surficial sea-bed sediments) has been undertaken in the study area. The combination of the two methodologies has produced a robust glacial geomorphological map for the study area. Four separate drumlin fields have been mapped in the study area indicative of fast-flowing and persistent ice-sheet flow configurations. A number of individual drumlins are also identified located outside the fields. The drumlins show as areas of high backscatter intensity compared to the surrounding sea bed, indicating the drumlins comprise mixed sediments of

  8. Sea Floor Topography and Backscatter Intensity of the Historic Area Remediation Site

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data set includes topography and backscatter intensity of the sea floor of the Historic Area Remediation Site (HARS), located offshore of New York and New...

  9. Laser light backscatter from intermediate and high Z plasmas

    Science.gov (United States)

    Berger, R. L.; Constantin, C.; Divol, L.; Meezan, N.; Froula, D. H.; Glenzer, S. H.; Suter, L. J.; Niemann, C.

    2006-09-01

    In experiments at the Omega Laser Facility [J. M. Soures et al., Fusion Technol. 30, 492 (1996)], stimulated Brillouin backscatter (SBS) from gasbags filled with krypton and xenon gases was ten times lower than from CO2-filled gasbags with similar electron densities. The SBS backscatter was a 1%-5% for both 527 and 351nm interaction beams at an intensity of ˜1015W /cm2. The SRS backscatter was less than 1%. The 351nm interaction beam is below the threshold for filamentation and the SBS occurs in the density plateau between the blast waves. Inverse bremsstrahlung absorption of the incident and SBS light account for the lower reflectivity from krypton than from CO2. The 527nm interaction beam filaments in the blowoff plasma before the beam propagates through the blast wave, where it is strongly absorbed. Thus, most of the 527nm SBS occurs in the flowing plasma outside the blast waves.

  10. Lidar monitoring of regions of intense backscatter with poorly defined boundaries

    Science.gov (United States)

    Vladimir A. Kovalev; Alexander Petkov; Cyle Wold; WeiMin Hao

    2011-01-01

    The upper height of a region of intense backscatter with a poorly defined boundary between this region and a region of clear air above it is found as the maximal height where aerosol heterogeneity is detectable, that is, where it can be discriminated from noise. The theoretical basis behind the retrieval technique and the corresponding lidar-data-processing procedures...

  11. Characterization of highly scattering media by measurement of diffusely backscattered polarized light

    Energy Technology Data Exchange (ETDEWEB)

    Hielscher, A.H.; Mourant, J.R.; Bigio, I.J.

    2000-01-04

    An apparatus and method for recording spatially dependent intensity patterns of polarized light that is diffusely backscattered from highly scattering media are described. These intensity patterns can be used to differentiate different turbid media, such as polystyrene-sphere and biological-cell suspensions. Polarized light from a He-Ne laser ({lambda} = 543 nm) is focused onto the surface of the scattering medium, and a surface area of approximately 4 x 4 cm centered on the light input point is imaged through polarization analysis optics onto a CCD camera. A variety of intensity patterns may be observed by varying the polarization state of the incident laser light and changing the analyzer configuration to detect different polarization components of the backscattered light. Experimental results for polystyrene-sphere and intralipid suspensions demonstrate that the radial and azimuthal variations of the observed pattern depend on the concentration, size, and anisotropy factor, g, of the particles constituting the scattering medium. Measurements performed on biological cell suspensions show that intensity patterns can be used to differentiate between suspensions of cancerous and non-cancerous cells. Introduction of the Mueller-matrix for diffusely backscattered light, permits the selection of a subset of measurements which comprehensively describes the optical properties of backscattering media.

  12. Characterization of highly scattering media by measurement of diffusely backscattered polarized light

    Energy Technology Data Exchange (ETDEWEB)

    Hielscher, Andreas H. (Brooklyn, NY); Mourant, Judith R. (Los Alamos, NM); Bigio, Irving J. (Los Alamos, NM)

    2000-01-01

    An apparatus and method for recording spatially dependent intensity patterns of polarized light that is diffusely backscattered from highly scattering media are described. These intensity patterns can be used to differentiate different turbid media, such as polystyrene-sphere and biological-cell suspensions. Polarized light from a He-Ne laser (.lambda.=543 nm) is focused onto the surface of the scattering medium, and a surface area of approximately 4.times.4 cm centered on the light input point is imaged through polarization analysis optics onto a CCD camera. A variety of intensity patterns may be observed by varying the polarization state of the incident laser light and changing the analyzer configuration to detect different polarization components of the backscattered light. Experimental results for polystyrene-sphere and Intralipid suspensions demonstrate that the radial and azimuthal variations of the observed pattern depend on the concentration, size, and anisotropy factor, g, of the particles constituting the scattering medium. Measurements performed on biological cell suspensions show that intensity patterns can be used to differentiate between suspensions of cancerous and non-cancerous cells. Introduction of the Mueller-matrix for diffusely backscattered light, permits the selection of a subset of measurements which comprehensively describes the optical properties of backscattering media.

  13. Simultaneous detection of rotational and translational motion in optical tweezers by measurement of backscattered intensity

    CERN Document Server

    Roy, Basudev; Banerjee, Ayan

    2014-01-01

    We describe a simple yet powerful technique of simultaneously measuring both translational and rotational motion of mesoscopic particles in optical tweezers by measuring the backscattered intensity on a quadrant photodiode (QPD). While the measurement of translational motion by taking the difference of the backscattered intensity incident on adjacent quadrants of a QPD is well-known, we demonstrate that rotational motion can be measured very precisely by taking the difference between the diagonal quadrants. The latter measurement eliminates the translational component entirely, and leads to a detection sensitivity of around 50 mdeg at S/N of 2 for angular motion of a driven micro-rod. The technique is also able to resolve the translational and rotational Brownian motion components of the micro-rod in an unperturbed trap, and can be very useful in measuring translation-rotation coupling of micro-objects induced by hydrodynamic interactions.

  14. Estimating suspended solids concentrations from backscatter intensity measured by acoustic Doppler current profiler in San Francisco Bay, California

    Science.gov (United States)

    Gartner, J.W.

    2004-01-01

    The estimation of mass concentration of suspended solids is one of the properties needed to understand the characteristics of sediment transport in bays and estuaries. However, useful measurements or estimates of this property are often problematic when employing the usual methods of determination from collected water samples or optical sensors. Analysis of water samples tends to undersample the highly variable character of suspended solids, and optical sensors often become useless from biological fouling in highly productive regions. Acoustic sensors, such as acoustic Doppler current profilers that are now routinely used to measure water velocity, have been shown to hold promise as a means of quantitatively estimating suspended solids from acoustic backscatter intensity, a parameter used in velocity measurement. To further evaluate application of this technique using commercially available instruments, profiles of suspended solids concentrations are estimated from acoustic backscatter intensity recorded by 1200- and 2400-kHz broadband acoustic Doppler current profilers located at two sites in San Francisco Bay, California. ADCP backscatter intensity is calibrated using optical backscatterance data from an instrument located at a depth close to the ADCP transducers. In addition to losses from spherical spreading and water absorption, calculations of acoustic transmission losses account for attenuation from suspended sediment and correction for nonspherical spreading in the near field of the acoustic transducer. Acoustic estimates of suspended solids consisting of cohesive and noncohesive sediments are found to agree within about 8-10% (of the total range of concentration) to those values estimated by a second optical backscatterance sensor located at a depth further from the ADCP transducers. The success of this approach using commercially available Doppler profilers provides promise that this technique might be appropriate and useful under certain conditions in

  15. Clinical Study of Ultrasonic Tissue Characterization with Integrated Backscatter and Echo Intensity in the Diagnosis of Acute Myocardial Infarction

    Institute of Scientific and Technical Information of China (English)

    王志刚; 冉海涛; 黄晶; 陈庆伟; 邹建中; 苏海兵; 蒲世玉; 凌智瑜; 陈永新; 何明菊

    2001-01-01

    Objectives The purpose of this study was to determine if the ultrasonic integrated backscatter and echo intensity could be used in clinical diagnosis of acute myocardial infarction. Methods and Results Within 2 weeks after acute myocardial infarction, 35 patients underwent ultrasonic tissue characterization from the papillary short- axis view.The cyclic variation of integrated backscatter and echo intensity of three different myocardial regions perfused by left anterior descending coronary artery, left cir cumflex coronary and right coronary were measured .The value of cyclic variation of integrated backscatter and integrated backscatter and echo intensity ≤ half of the highest value of three different myocardial regions on a same view were define as the criteria for diag nosing acute myocardial infarction , and the results were compared with coronary angiography. The sensitivity of diagnosing acute myocardial infarction by both Ultrasonic tissue characterization with integrated backscatter and echo intensity were 91.43 % . The location of myocardial infarction detected by this technique corresponded with the damaged myocardial region determined by coronary angiography. Conclusions Ultrasonic tissue characterization with integrated backscatter and echo intensity could clinically be used as a noninvasive approach in the diagnosis of acute myocardial infarction.

  16. Active-layer thickness estimation from X-band SAR backscatter intensity

    Science.gov (United States)

    Widhalm, Barbara; Bartsch, Annett; Leibman, Marina; Khomutov, Artem

    2017-02-01

    The active layer above the permafrost, which seasonally thaws during summer, is an important parameter for monitoring the state of permafrost. Its thickness is typically measured locally, but a range of methods which utilize information from satellite data exist. Mostly, the normalized difference vegetation index (NDVI) obtained from optical satellite data is used as a proxy. The applicability has been demonstrated mostly for shallow depths of active-layer thickness (ALT) below approximately 70 cm. Some permafrost areas including central Yamal are, however, characterized by larger ALT. Surface properties including vegetation structure are also represented by microwave backscatter intensity. So far, the potential of such data for estimating ALT has not been explored. We therefore investigated the relationship between ALT and X-band synthetic aperture radar (SAR) backscatter of TerraSAR-X (averages for 10 × 10 m window) in order to examine the possibility of delineating ALT with continuous and larger spatial coverage in this area and compare it to the already-established method of using NDVI from Landsat (30 m). Our results show that the mutual dependency of ALT and TerraSAR-X backscatter on land cover types suggests a connection of both parameters. A range of 5 dB can be observed for an ALT range of 100 cm (40-140 cm), and an R2 of 0.66 has been determined over the calibration sites. An increase of ALT with increasing backscatter can be determined. The root mean square error (RMSE) over a comparably heterogeneous validation site with maximum ALT of > 150 cm is 20 cm. Deviations are larger for measurement locations with mixed vegetation types (especially partial coverage by cryptogam crust) with respect to the spatial resolution of the satellite data.

  17. Study on the backscattered light intensity to airborne laser range-gated imaging

    Science.gov (United States)

    Wang, Ling; Yu, Lei; Kou, Tian; Wu, Xueming

    2016-10-01

    Based on the range-gated technology in the application of airborne laser detection imaging system, sequence relations of the parameters in the model of range gating in detail was analyzed. The effective scope of atmospheric backscatter and the moment before or after pulsing of the unit section was obtained. Horizontal range-gated imaging model was established and the calculation method of backscattered light intensity was given. Then slant distance detection of airborne laser active imaging was revised. By the object-image relation of points on the scattering section, the light path diagram of imaging detection system was built and the corresponding relation of light intensity between scattering points and receiving points was given. The variation regularity and distribution of light intensity on the detector under horizontal and slant detection were gained. Under the idea, the outfield testing platform was set up, and the relative error of data between measured and simulated results was controlled within 5%. The two kinds of data achieved a good coincident, which demonstrated the effectiveness of the built model. The two kinds of data achieved a good coincident, which demonstrated the effectiveness of the built model.

  18. Dynamic coherent backscattering mirror

    Energy Technology Data Exchange (ETDEWEB)

    Zeylikovich, I.; Xu, M., E-mail: mxu@fairfield.edu [Physics Department, Fairfield University, Fairfield, CT 06824 (United States)

    2016-02-15

    The phase of multiply scattered light has recently attracted considerable interest. Coherent backscattering is a striking phenomenon of multiple scattered light in which the coherence of light survives multiple scattering in a random medium and is observable in the direction space as an enhancement of the intensity of backscattered light within a cone around the retroreflection direction. Reciprocity also leads to enhancement of backscattering light in the spatial space. The random medium behaves as a reciprocity mirror which robustly converts a diverging incident beam into a converging backscattering one focusing at a conjugate spot in space. Here we first analyze theoretically this coherent backscattering mirror (CBM) phenomenon and then demonstrate the capability of CBM compensating and correcting both static and dynamic phase distortions occurring along the optical path. CBM may offer novel approaches for high speed dynamic phase corrections in optical systems and find applications in sensing and navigation.

  19. Dynamic coherent backscattering mirror

    Science.gov (United States)

    Xu, M.

    2016-01-01

    The phase of multiply scattered light has recently attracted considerable interest. Coherent backscattering is a striking phenomenon of multiple scattered light in which the coherence of light survives multiple scattering in a random medium and is observable in the direction space as an enhancement of the intensity of backscattered light within a cone around the retroreflection direction. Reciprocity also leads to enhancement of backscattering light in the spatial space. The random medium behaves as a reciprocity mirror which robustly converts a diverging incident beam into a converging backscattering one focusing at a conjugate spot in space. Here we first analyze theoretically this coherent backscattering mirror (CBM) phenomenon and then demonstrate the capability of CBM compensating and correcting both static and dynamic phase distortions occurring along the optical path. CBM may offer novel approaches for high speed dynamic phase corrections in optical systems and find applications in sensing and navigation. PMID:26937296

  20. Thomson backscattering from laser generated, relativistically moving high-density electron layers

    CERN Document Server

    Paz, Athena E; Rödel, Christian; Schnell, Michael; Jäckel, Oliver; Kaluza, Malte C; Paulus, Gerhard G

    2012-01-01

    We show experimentally that XUV radiation is produced when a laser pulse is Thomson backscattered from sheets of relativistic electrons which are formed at the rear-surface of a foil irradiated on its front side by a high-intensity laser. An all-optical setup is realized using the Jena Titanium:Sapphire TW laser system (JETI). The main pulse is split into two pulses: one to accelerate electrons from thin aluminum foil targets to energies of the order of some MeV and the other, counterpropagating probe pulse is Thomson-backscattered off these electrons when they exit the target rear side. The process produced photons within a wide spectral range of some tens of eV as a result of the broad electron energy distribution. The highest scattering intensity is observed when the probe pulse arrives at the target rear surface 100 fs after the irradiation of the target front side by the pump pulse, corresponding to the maximum flux of hot electrons at the interaction region. These results can provide time-resolved infor...

  1. High resolution energy-angle correlation measurement of hard x rays from laser-Thomson backscattering.

    Science.gov (United States)

    Jochmann, A; Irman, A; Bussmann, M; Couperus, J P; Cowan, T E; Debus, A D; Kuntzsch, M; Ledingham, K W D; Lehnert, U; Sauerbrey, R; Schlenvoigt, H P; Seipt, D; Stöhlker, Th; Thorn, D B; Trotsenko, S; Wagner, A; Schramm, U

    2013-09-13

    Thomson backscattering of intense laser pulses from relativistic electrons not only allows for the generation of bright x-ray pulses but also for the investigation of the complex particle dynamics at the interaction point. For this purpose a complete spectral characterization of a Thomson source powered by a compact linear electron accelerator is performed with unprecedented angular and energy resolution. A rigorous statistical analysis comparing experimental data to 3D simulations enables, e.g., the extraction of the angular distribution of electrons with 1.5% accuracy and, in total, provides predictive capability for the future high brightness hard x-ray source PHOENIX (photon electron collider for narrow bandwidth intense x rays) and potential gamma-ray sources.

  2. High-energy gamma-ray beams from Compton-backscattered laser light

    Energy Technology Data Exchange (ETDEWEB)

    Sandorfi, A.M.; LeVine, M.J.; Thorn, C.E.; Giordano, G.; Matone, G.

    1983-01-01

    Collisions of light photons with relativistic electrons have previously been used to produce polarized ..gamma..-ray beams with modest (-10%) resolution but relatively low intensity. In contrast, the LEGS project (Laser + Electron Gamma Source) at Brookhaven will produce a very high flux (>2 x 10/sup 7/ s/sup -1/) of background-free polarized ..gamma.. rays whose energy will be determined to a high accuracy (..delta..E = 2.3 MeV). Initially, 300(420)-MeV ..gamma.. rays will be produced by backscattering uv light from the new 2.5(3.0)-GeV X-ray storage ring of the National Synchrotron Light Source (NSLS). The LEGS facility will operate as one of many passive users of the NSLS. In a later stage of the project, a Free Electron Laser is expectred to extend the ..gamma..-ray energy up to 700 MeV.

  3. GeoTIFF image of the backscatter intensity of the sea floor offshore of Moriches Inlet, New York, in 1998 (3-m resolution, Mercator, WGS 84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Surveys of the bathymetry and backscatter intensity of the sea floor south of Long Island, New York, were carried out in November 1998 using a Simrad EM1000...

  4. GeoTIFF image of the backscatter intensity of the sea floor offshore of Fire Island Inlet, New York, in 1998 (3-m resolution, Mercator, WGS 84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Surveys of the bathymetry and backscatter intensity of the sea floor south of Long Island, New York, were carried out in November 1998 using a Simrad EM1000...

  5. GeoTIFF image of the backscatter intensity of the sea floor offshore of Shinnecock Inlet, New York, in 1998 (3-m resolution, Mercator, WGS 84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Surveys of the bathymetry and backscatter intensity of the sea floor south of Long Island, New York, were carried out in November 1998 using a Simrad EM1000...

  6. GeoTIFF image of the backscatter intensity of the sea floor southwest of Montauk Point, New York, in 1998 (3-m resolution, Mercator, WGS 84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Surveys of the bathymetry and backscatter intensity of the sea floor south of Long Island, New York, were carried out in November 1998 using a Simrad EM1000...

  7. Concentration measurement of yeast suspensions using high frequency ultrasound backscattering.

    Science.gov (United States)

    Elvira, Luis; Vera, Pedro; Cañadas, Francisco Jesús; Shukla, Shiva Kant; Montero, Francisco

    2016-01-01

    This work proposes the use of an ultrasound based technique to measure the concentration of yeasts in liquid suspension. This measurement was achieved by the detection and quantification of ultrasonic echoes backscattered by the cells. More specifically, the technique was applied to the detection and quantification of Saccharomyces cerevisiae. A theoretical approach was proposed to get the average density and sound speed of the yeasts, which were found to be 1116 kg/m(3) and 1679 m/s, respectively. These parameters were needed to model the waves backscattered by each single cell. A pulse-echo arrangement working around 50 MHz, being able to detect echoes from single yeasts was used to characterize experimentally yeast solutions from 10(2) to 10(7)cells/ml. The Non-negative Matrix Factorization denoising technique was applied for data analysis. This technique required a previous learning of the spectral patterns of the echoes reflected from yeasts in solution and the base noise from the liquid medium. Comparison between pulse correlation (without denoising) and theoretical and experimental pattern learning was made to select the best signal processing. A linear relation between ultrasound output and concentration was obtained with correlation coefficient R(2)=0.996 for the experimental learning. Concentrations from 10(4) to 10(7)cells/ml were detected above the base noise. These results show the viability of using the ultrasound backscattering technique to detect yeasts and measure their concentration in liquid cultures, improving the sensitivity obtained using spectrophotometric methods by one order of magnitude.

  8. High resolution backscattering studies of nanostructured magnetic and semiconducting materials

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, A. [Instituto Tecnologico e Nuclear, Dept. Fisica, Estrada Nac. 10, 2686-953 Sacavem (Portugal)]. E-mail: afonseca@itn.pt; Franco, N. [Instituto Tecnologico e Nuclear, Dept. Fisica, Estrada Nac. 10, 2686-953 Sacavem (Portugal); Alves, E. [Instituto Tecnologico e Nuclear, Dept. Fisica, Estrada Nac. 10, 2686-953 Sacavem (Portugal); Centro de Fisica Nuclear da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Barradas, N.P. [Instituto Tecnologico e Nuclear, Dept. Fisica, Estrada Nac. 10, 2686-953 Sacavem (Portugal); Centro de Fisica Nuclear da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Leitao, J.P. [Departamento de Fisica da Universidade de Aveiro, 3810-193 Aveiro (Portugal); Sobolev, N.A. [Departamento de Fisica da Universidade de Aveiro, 3810-193 Aveiro (Portugal); Banhart, D.F. [Z. E. Elektronenmikroskopie, Universitaet Ulm, Albert-Einstein-Allee 11, D-89069 Ulm (Germany); Presting, H. [Daimler-Chrysler Forschungszentrum, 89081 Ulm (Germany); Ulyanov, V.V. [Institute of Semiconductor Physics, 630090 Novosibirsk (Russian Federation); Nikiforov, A.I. [Institute of Semiconductor Physics, 630090 Novosibirsk (Russian Federation)

    2005-12-15

    Low dimension structures raises inevitably new technological challenges in materials science. The new structures must fulfill stringent requirements in composition, crystalline quality and interface sharpness among others. We present and discuss the results of Si/Ge quantum structures and FePt/C multilayer structures deposited at different temperatures by ion beam sputtering. Evidence for the presence of FePt nanoparticles embedded in the C matrix and Ge islands in Ge/Si multilayers structures was found. Size and stoichiometry of the nanoparticles and the multilayer periodicity was obtained using Rutherford backscattering at grazing angles of incidence. The strain state of the single crystalline layers was determined by tilt axis channelling.

  9. Computation of Nonlinear Backscattering Using a High-Order Numerical Method

    Science.gov (United States)

    Fibich, G.; Ilan, B.; Tsynkov, S.

    2001-01-01

    The nonlinear Schrodinger equation (NLS) is the standard model for propagation of intense laser beams in Kerr media. The NLS is derived from the nonlinear Helmholtz equation (NLH) by employing the paraxial approximation and neglecting the backscattered waves. In this study we use a fourth-order finite-difference method supplemented by special two-way artificial boundary conditions (ABCs) to solve the NLH as a boundary value problem. Our numerical methodology allows for a direct comparison of the NLH and NLS models and for an accurate quantitative assessment of the backscattered signal.

  10. The effect of pattern overlap on the accuracy of high resolution electron backscatter diffraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Vivian, E-mail: v.tong13@imperial.ac.uk [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Jiang, Jun [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Wilkinson, Angus J. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Britton, T. Ben [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom)

    2015-08-15

    High resolution, cross-correlation-based, electron backscatter diffraction (EBSD) measures the variation of elastic strains and lattice rotations from a reference state. Regions near grain boundaries are often of interest but overlap of patterns from the two grains could reduce accuracy of the cross-correlation analysis. To explore this concern, patterns from the interior of two grains have been mixed to simulate the interaction volume crossing a grain boundary so that the effect on the accuracy of the cross correlation results can be tested. It was found that the accuracy of HR-EBSD strain measurements performed in a FEG-SEM on zirconium remains good until the incident beam is less than 18 nm from a grain boundary. A simulated microstructure was used to measure how often pattern overlap occurs at any given EBSD step size, and a simple relation was found linking the probability of overlap with step size. - Highlights: • Pattern overlap occurs at grain boundaries and reduces HR-EBSD accuracy. • A test is devised to measure the accuracy of HR-EBSD in the presence of overlap. • High pass filters can sometimes, but not generally, improve HR-EBSD measurements. • Accuracy of HR-EBSD remains high until the reference pattern intensity is <72%. • 9% of points near a grain boundary will have significant error for 200nm step size in Zircaloy-4.

  11. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  12. Relationships between spatial patterns of macrofauna communities, sediments and hydroacoustic backscatter data in a highly heterogeneous and anthropogenic altered environment

    Science.gov (United States)

    Gutperlet, R.; Capperucci, R. M.; Bartholomä, A.; Kröncke, I.

    2017-03-01

    A survey was conducted in the Inner Jade tidal channel, the connection between the Jade Bay and the southern North Sea, to investigate the relationships between macrofauna community structure and environmental variables in a highly heterogeneous human disturbed environment. A manual expertise based classification of sidescan sonar records was successful in confirming the general relationship between backscatter intensity and sediment grain size in weakly disturbed environments. In highly disturbed environments, instead, the classification showed the influence of the topographic roughness over the sediment roughness in backscatter intensity. Low, but significant relationships between hydroacoustic classification and macrofauna community structure, as well as sediment distribution and the macrofaunal communities were identified. The most important impact on spatial community structure was the number of days after dredging/dumping activity for the JadeWeserPort, followed by sediment characteristics. Sand dominated western stations that were dredged for the JWP exhibited a characteristic macrofaunal community. Another distinct community occurred in stations with elevated mud content within the regularly dredged old navigation channel and in the undisturbed south eastern area. The macrofaunal communities in the north eastern undisturbed area coincided with elevated gravel and shell contents. This study stresses the problems of benthic habitat mapping in such a heterogeneous area.

  13. Aerosol backscatter measurements at 10. 6 micrometers with airborne and ground-based CO sub 2 Doppler lidars over the Colorado high plains. 2. Backscatter structure

    Energy Technology Data Exchange (ETDEWEB)

    Bowdle, D.A. (Univ. of Alabama, Huntsville (USA)); Rothermel, J. (NASA Marshall Space Flight Center, Huntsville, AL (USA)); Vaughan, J.M. (Royal Signals and Radar Establishment, Worcestershire (England)); Post, M.J. (National Oceanic and Atmospheric Administration, Boulder, CO (USA))

    1991-03-20

    Measurements of tropospheric aerosol volume backscatter coefficients at 10.6-{mu}m wavelength were obtained with airborne continuous wave and ground-based pulsed CO{sub 2} Doppler lidars over the Colorado High Plains during a 20-day period in summer 1982. A persistent 'background' layer was found between 6- and 10-km altitude, with a generally uniform backscatter mixing ratio of {approximately}10{sup {minus}10} m{sup 2} kg{sup {minus}1} sr{sup {minus}1}. The upper boundary of this background layer varied with the tropopause height; the lower boundary varied with the strength and diurnal cycle of convective mixing in the planetary boundary layer (PBL). For quiescent meteorological conditions the transition from the PBL to the background layer was usually very sharp, with backscatter decreases sometimes as large as 3 decades in {approximately}70 m. Sharp gradients were also found at the boundaries of shallow (tens of meters) subvisible cirrus clouds. For less stable conditions, associated with vertical aerosol transport by deep comuliform clouds, backscatter tended to decrease exponentially with altitude.

  14. SPHERES, J\\"ulich's High-Flux Neutron Backscattering Spectrometer at FRM II

    CERN Document Server

    Wuttke, Joachim; Drochner, Matthias; Kämmerling, Hans; Kayser, Franz-Joseph; Pardo, Luis Carlos; Prager, Michael; Ossovyi, Vladimir; Schneider, Gerald J; Schneider, Harald; Staringer, Simon; Richter, Dieter

    2012-01-01

    SPHERES (SPectrometer with High Energy RESolution) is a third-generation neutron backscattering spectrometer, located at the 20 MW German neutron source FRM II and operated by the J\\"ulich Centre for Neutron Science. It offers an energy resolution (fwhm) better than 0.65 micro-eV, a dynamic range of +-31 micro-eV, and a signal-to-noise ratio of up to 1750:1.

  15. Radiological Shielding Design for the Neutron High-Resolution Backscattering Spectrometer EMU at the OPAL Reactor

    Science.gov (United States)

    Ersez, Tunay; Esposto, Fernando; Souza, Nicolas R. de

    2017-09-01

    The shielding for the neutron high-resolution backscattering spectrometer (EMU) located at the OPAL reactor (ANSTO) was designed using the Monte Carlo code MCNP 5-1.60. The proposed shielding design has produced compact shielding assemblies, such as the neutron pre-monochromator bunker with sliding cylindrical block shields to accommodate a range of neutron take-off angles, and in the experimental area - shielding of neutron focusing guides, choppers, flight tube, backscattering monochromator, and additional shielding elements inside the Scattering Tank. These shielding assemblies meet safety and engineering requirements and cost constraints. The neutron dose rates around the EMU instrument were reduced to < 0.5 µSv/h and the gamma dose rates to a safe working level of ≤ 3 µSv/h.

  16. Development and demonstration of a high-altitude atmospheric backscatter Lidar system

    Science.gov (United States)

    Dolash, Thomas M.; Garvey, John; Leonelli, Joseph; Bradford, Mark; Rose, Lynn

    1994-06-01

    Battelle has designed and fabricated an upward-looking atmospheric backscatter lidar for high-altitude airborne applications. The compact, rugged system was assembled and integrated into a cupola on top of a Lear 36 aircraft to provide particle backscatter data and aerosol profile distributions of cirrus clouds occurring between 50,000 and 100,000 ft ASL. The high altitude airborne lidar system consists of a laser transmitter operating at 532 and 1064 nm simultaneously with output energy of 75 mJ at both wavelengths and a collecting telescope aperture of 10 inches in diameter. Laser backscatter energy is collected and directed via a dichroic beamsplitter to two avalanche photodetectors (APD) through narrow bandpass optical filters at 532 and 1064 nm. The outputs of the APDs are digitized by a 10-bit, 100-MHz transient digitizer before being recorded to a 1.2-Gbyte hard disk with IRIG timing for data analysis. This paper describes the lidar system design, predicted performance, and some of the operational challenges.

  17. GLOBE backscatter - Climatologies and mission results. [Global Backscatter Experiment

    Science.gov (United States)

    Menzies, Robert T.; Post, Madison J.

    1991-01-01

    The Global Backscatter Experiment (GLOBE) goals require intensive study of the global climatology of atmospheric aerosol backscatter at IR wavelengths. Airborne and ground-based lidars have been developed to measure atmospheric backscatter profiles at CO2 laser wavelengths. Descriptions of the calibration techniques and selected measurement results are presented.

  18. GeoTIFF image of shaded-relief bathymetry, colored by backscatter intensity, of the sea floor southwest of Montauk Point, New York, in 1998 (3-m resolution, Mercator, WGS 84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Surveys of the bathymetry and backscatter intensity of the sea floor south of Long Island, New York, were carried out in November 1998 using a Simrad EM1000...

  19. GeoTIFF image of shaded-relief bathymetry, colored by backscatter intensity, of the sea floor offshore of Moriches Inlet, New York, in 1998 (3-m resolution, Mercator, WGS 84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Surveys of the bathymetry and backscatter intensity of the sea floor south of Long Island, New York, were carried out in November 1998 using a Simrad EM1000...

  20. GeoTIFF image of shaded-relief bathymetry, colored by backscatter intensity, of the sea floor offshore of Shinnecock Inlet, New York, in 1998 (3-m resolution, Mercator, WGS 84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Surveys of the bathymetry and backscatter intensity of the sea floor south of Long Island, New York, were carried out in November 1998 using a Simrad EM1000...

  1. GeoTIFF image of shaded-relief bathymetry, colored by backscatter intensity, of the sea floor offshore of Fire Island Inlet, New York, in 1998 (3-m resolution, Mercator, WGS 84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Surveys of the bathymetry and backscatter intensity of the sea floor south of Long Island, New York, were carried out in November 1998 using a Simrad EM1000...

  2. 4-m Image of the Southern Half of the Backscatter Intensity Mosaic of the Sea Floor off Eastern Cape Cod from USGS Cruise 98015 (CAPESOUTHMOS_GEO4M_WGS84.TIF, Geographic, WGS84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data set includes backscatter intensity of the sea floor offshore of eastern Cape Cod, Massachusetts. The data were collected with a multibeam sea floor mapping...

  3. 4-m Image of the Northern Half of the Backscatter Intensity Mosaic of the Sea Floor off Northeastern Cape Cod from USGS Cruise 98015 (CAPENORTHMOS_GEO4M_WGS84.TIF, Geographic, WGS84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data set includes backscatter intensity of the sea floor offshore of northern Cape Cod, Massachusetts. The data were collected with a multibeam sea floor...

  4. 4-m Image of the Southern Half of the Pseudo-colored Backscatter Intensity of the Sea Floor off Eastern Cape Cod (CAPESOUTHPSEUDO_GEO4M_WGS84.TIF, Geographic, WGS84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data set includes pseudo-colored backscatter intensity of the sea floor offshore of northeastern Cape Cod, Massachusetts. The data were collected with a...

  5. 4-m Image of the Southern Half of the Backscatter Intensity Mosaic of the Sea Floor off Eastern Cape Cod from USGS Cruise 98015 (CAPESOUTHMOS_GEO4M_WGS84.TIF, Geographic, WGS84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data set includes backscatter intensity of the sea floor offshore of eastern Cape Cod, Massachusetts. The data were collected with a multibeam sea floor mapping...

  6. 4-m Image of the Northern Half of the Backscatter Intensity Mosaic of the Sea Floor off Northeastern Cape Cod from USGS Cruise 98015 (CAPENORTHMOS_GEO4M_WGS84.TIF, Geographic, WGS84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data set includes backscatter intensity of the sea floor offshore of northern Cape Cod, Massachusetts. The data were collected with a multibeam sea floor...

  7. 4-m Image of the Northern Half of the Pseudo-colored Backscatter Intensity of the Sea Floor off Northeastern Cape Cod (CAPENORTHPSEUDO_GEO4M_WGS84.TIF, Geographic, WGS84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data set includes pseudo-colored backscatter intensity of the sea floor offshore of northeastern Cape Cod, Massachusetts. The data were collected with a...

  8. 4-m Image of the Southern Half of the Backscatter Intensity Mosaic of the Sea Floor off Eastern Cape Cod from USGS Cruise 98015 (CAPESOUTHMOS_GEO4M_WGS84.TIF, Geographic, WGS84)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data set includes backscatter intensity of the sea floor offshore of eastern Cape Cod, Massachusetts. The data were collected with a multibeam sea floor...

  9. LHC Report: reaching high intensity

    CERN Multimedia

    Jan Uythoven

    2015-01-01

    After both beams having been ramped to their full energy of 6.5 TeV, the last two weeks saw the beam commissioning process advancing on many fronts. An important milestone was achieved when operators succeeded in circulating a nominal-intensity bunch. During the operation, some sudden beam losses resulted in beam dumps at top energy, a problem that needed to be understood and resolved.   In 2015 the LHC will be circulating around 2800 bunches in each beam and each bunch will contain just over 1 x 1011 protons. Until a few days ago commissioning was taking place with single bunches of 5 x 109 protons. The first nominal bunch with an intensity of 1 x 1011 protons was injected on Tuesday, 21 April. In order to circulate such a high-intensity bunch safely, the whole protection system must be working correctly: collimators, which protect the aperture, are set at preliminary values known as coarse settings; all kicker magnets for injecting and extracting the beams are commissioned with beam an...

  10. Thomson backscattering diagnostics of nanosecond electron bunches in high space charge regime

    CERN Document Server

    Paroli, B

    2012-01-01

    The intra-beam repulsions play a significant role in determining the performances of free-electron devices when an high brilliance of the beam is required. The transversal and longitudinal spread of the beam, its energy and density are fundamental parameters in any beam experiment and different beam diagnostics are available to measure such parameters. A diagnostic method based on the Thomson backscattering of a laser beam impinging on the particle beam is proposed in this work for the study of nanosecond electron bunches in high space charge regime. This diagnostics, aimed to the measurement of density, energy and energy spread, was set-up in a Malmberg-Penning trap (generally used for the electron/ion confinment) in two different configurations designed to optimize sensitivity, spatial resolution and electron-beam coincidence in space and time. To this purpose an electron bunch (pulse time <4ns), produced by a photocathode source, was preliminary characterized with different electrostatic diagnostics and...

  11. Characteristics and short-term changes of the Po Delta seafloor morphology through high-resolution bathymetric and backscatter data

    Science.gov (United States)

    Madricardo, Fantina; Bosman, Alessandro; Kruss, Aleksandra; Remia, Alessandro; Correggiari, Anna; Fogarin, Stefano; Romagnoli, Claudia; Moscon, Giorgia

    2016-04-01

    instability phenomena along the slope. Moreover, the acoustic backscatter intensity data and grab samples collected in the area provided information about the superficial sediment distribution during the two surveys, while the study of the water-column backscatter intensity revealed the presence of gas plume in the water-column. These results contribute to a better understanding the recent sediment dynamics and evolution of the Po Delta system.

  12. Morphology and possible origins of near-range oblique HF backscatter at high and midlatitudes

    Science.gov (United States)

    Ponomarenko, Pavlo, V.; Iserhienrhien, Blessing; St.-Maurice, Jean-Pierre

    2016-06-01

    High-frequency radars (HF, ˜10-20 MHz) forming the Super Dual Auroral Radar Network (SuperDARN) regularly observe returns from very close ranges of ≤300-400 km (near-range echoes, NREs). These echoes are conventionally attributed to backscatter from meteor trails, but other sources of NRE have been invoked, including polar mesospheric summer echoes (PMSE), and non-field-aligned E region irregularities leading to high-aspect ionospheric returns. In order to relate NRE to a particular mechanism, it is essential to establish beforehand their spatiotemporal trends with respect to season, local time, and latitude. Systematic information of this kind is generally lacking from the literature, so we attempt to fill the gap by performing a statistical analysis of such echoes observed by five radars covering midlatitudes to polar latitudes over all seasons and local times. We detected two major echo populations which were observed at each radar site: (i) a nightside-early morning returns representing the well-known meteor backscatter and (ii) a midsummer population centered near the local noon. At high latitudes the summer daytime echoes are usually interpreted as PMSE, but the observed population extends to much lower latitudes and is centered well above the conventional PMSE height range. We hypothesize that this population could be related to neutral turbulence in the lower E region. In addition, there was a pronounced evening population restricted to the auroral region which we provisionally attribute to irregularities generated by the precipitating energetic particles and strong electric fields.

  13. A Multivariate Correlation Analysis of High- Frequency Bottom Backscattering Strength Measurements With Geotechnical Parameters

    NARCIS (Netherlands)

    Simons, D.G.; Snellen, M.; Ainslie, M.A.

    2007-01-01

    Sound backscattered from the seabed has been measured in a 10x10-nmi2 region of the North Sea, characterized by a variety of bottom types, including mud, sand, and gravel. The backscattering strength measurements are made by a forward- looking sonar, operating at 100 kHz and tilted at an angle of 30

  14. A multivariate correlation analysis of high-frequency bottom backscattering strength measurements with geotechnical parameters

    NARCIS (Netherlands)

    Simons, D.G.; Snellen, M.; Ainslie, M.A.

    2007-01-01

    Sound backscattered from the seabed has been measured in a 10 × 10-nmi2 region of the North Sea, characterized by a variety of bottom types, including mud, sand, and gravel. The backscattering strength measurements are made by a forward-looking sonar, operating at 100 kHz and tilted at an angle of 3

  15. Effects of Noise and Absorption on High Frequency Measurements of Acoustic-Backscatter from Fish

    Directory of Open Access Journals (Sweden)

    Masahiko Furusawa

    2015-01-01

    Full Text Available Quantitative echosounders operating at multiple frequencies (e.g., 18, 38, 70, 120, 200, 333, and 710 kHz are often used to observe fish and zooplankton and identify their species. At frequencies above 100 kHz, the absorption attenuation increases rapidly and decreases the signal-to-noise ratio (SNR. Also, incomplete compensation for the attenuation may result in measurement error. This paper addresses the effects of the attenuation and noise on high frequency measurements of acoustic backscatter from fish. It is shown that measurements of a fish with target strength of −40 dB at 200 m depth are limited by SNR to frequencies up to about 100 kHz. Above 100 kHz, absorption coefficients must be matched to local environmental conditions.

  16. Quantitative assessments of burn degree by high-frequency ultrasonic backscattering and statistical model

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yi-Hsun; Wang, Shyh-Hau [Department of Computer Science and Information Engineering, and Institute of Medical Informatics, National Cheng Kung University, No 1, University Road, Tainan City 70101, Taiwan (China); Huang, Chih-Chung, E-mail: shyhhau@mail.ncku.edu.tw [Department of Electrical Engineering, Fu Jen Catholic University, 510, Chung Cheng Rd, Hsin Chuang, Taipei County 24205, Taiwan (China)

    2011-02-07

    An accurate and quantitative modality to assess the burn degree is crucial for determining further treatments to be properly applied to burn injury patients. Ultrasounds with frequencies higher than 20 MHz have been applied to dermatological diagnosis due to its high resolution and noninvasive capability. Yet, it is still lacking a substantial means to sensitively correlate the burn degree and ultrasonic measurements quantitatively. Thus, a 50 MHz ultrasound system was developed and implemented to measure ultrasonic signals backscattered from the burned skin tissues. Various burn degrees were achieved by placing a 100 deg. C brass plate onto the dorsal skins of anesthetized rats for various durations ranged from 5 to 20 s. The burn degrees were correlated with ultrasonic parameters, including integrated backscatter (IB) and Nakagami parameter (m) calculated from ultrasonic signals acquired from the burned tissues of a 5 x 1.4 mm (width x depth) area. Results demonstrated that both IB and m decreased exponentially with the increase of burn degree. Specifically, an IB of -79.0 {+-} 2.4 (mean {+-} standard deviation) dB for normal skin tissues tended to decrease to -94.0 {+-} 1.3 dB for those burned for 20 s, while the corresponding Nakagami parameters tended to decrease from 0.76 {+-} 0.08 to 0.45 {+-} 0.04. The variation of both IB and m was partially associated with the change of properties of collagen fibers from the burned tissues verified by samples of tissue histological sections. Particularly, the m parameter may be more sensitive to differentiate burned skin due to the fact that it has a greater rate of change with respect to different burn durations. These ultrasonic parameters in conjunction with high-frequency B-mode and Nakagami images could have the potential to assess the burn degree quantitatively.

  17. Phase space distribution of an electron beam emerging from Compton/Thomson back-scattering by an intense laser pulse

    Science.gov (United States)

    Petrillo, V.; Chaikovska, I.; Ronsivalle, C.; Rossi, A. R.; Serafini, L.; Vaccarezza, C.

    2013-01-01

    We analyze the energy distribution of a relativistic electron beam after the Compton back-scattering by a counterpropagating laser field. The analysis is performed for parameters in the range of realistic X-γ sources, in the framework of the Quantum Electrodynamics, by means of the code CAIN. The results lead to the conclusion that, in the regime considered, the main effect is the initial formation of stripes, followed by the diffusion of the most energetic particles toward lower values in the longitudinal phase space, with a final increase of the electron energy bandwidth.

  18. A Multivariate Correlation Analysis of High- Frequency Bottom Backscattering Strength Measurements With Geotechnical Parameters

    OpenAIRE

    2007-01-01

    Sound backscattered from the seabed has been measured in a 10x10-nmi2 region of the North Sea, characterized by a variety of bottom types, including mud, sand, and gravel. The backscattering strength measurements are made by a forward- looking sonar, operating at 100 kHz and tilted at an angle of 30 from the horizontal. Fifty bottom-grab samples, representative of the uppermost 20 cm, were taken and analyzed for gravel content, shell content, and grain-size distribution. The backscatter measu...

  19. An equivalent roughness model for seabed backscattering at very high frequencies using a band-matrix approach

    DEFF Research Database (Denmark)

    Wendelboe, Gorm; Jacobsen, Finn; Bell, Judith

    2007-01-01

    This work concerns modeling of very high frequency (>100 kHz) sonar images obtained from a sandy seabed. The seabed is divided into a discrete number of 1D height profiles. For each height profile the backscattered pressure is computed by an integral equation method for interface scattering between...

  20. High-resolution multibeam backscatter data - northern Channel Islands region, southern California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data release presents data for 5-m resolution acoustic-backscatter data of the northern Channel Islands region, southern California. The raster data files are...

  1. High-resolution multibeam backscatter data - northern Channel Islands region, southern California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This data release presents data for 5-m resolution acoustic-backscatter data of the northern Channel Islands region, southern California. The raster data files are...

  2. Geometrically necessary dislocation densities in olivine obtained using high-angular resolution electron backscatter diffraction.

    Science.gov (United States)

    Wallis, David; Hansen, Lars N; Ben Britton, T; Wilkinson, Angus J

    2016-09-01

    Dislocations in geological minerals are fundamental to the creep processes that control large-scale geodynamic phenomena. However, techniques to quantify their densities, distributions, and types over critical subgrain to polycrystal length scales are limited. The recent advent of high-angular resolution electron backscatter diffraction (HR-EBSD), based on diffraction pattern cross-correlation, offers a powerful new approach that has been utilised to analyse dislocation densities in the materials sciences. In particular, HR-EBSD yields significantly better angular resolution (olivine, the dominant mineral in Earth's upper mantle by testing (1) different inversion methods for estimating geometrically necessary dislocation (GND) densities, (2) the sensitivity of the method under a range of data acquisition settings, and (3) the ability of the technique to resolve a variety of olivine dislocation structures. The relatively low crystal symmetry (orthorhombic) and few slip systems in olivine result in well constrained GND density estimates. The GND density noise floor is inversely proportional to map step size, such that datasets can be optimised for analysing either short wavelength, high density structures (e.g. subgrain boundaries) or long wavelength, low amplitude orientation gradients. Comparison to conventional images of decorated dislocations demonstrates that HR-EBSD can characterise the dislocation distribution and reveal additional structure not captured by the decoration technique. HR-EBSD therefore provides a highly effective method for analysing dislocations in olivine and determining their role in accommodating macroscopic deformation.

  3. High intensity protons in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Montag, C.; Ahrens, L.; Blaskiewicz, M.; Brennan, J. M.; Drees, K. A.; Fischer, W.; Huang, H.; Minty, M.; Robert-Demolaize, G.; Thieberger, P.; Yip, K.

    2012-01-05

    During the 2012 summer shutdown a pair of electron lenses will be installed in RHIC, allowing the beam-beam parameter to be increased by roughly 50 percent. To realize the corresponding luminosity increase bunch intensities have to be increased by 50 percent, to 2.5 {center_dot} 10{sup 11} protons per bunch. We list the various RHIC subsystems that are most affected by this increase, and propose beam studies to ensure their readiness. The proton luminosity in RHIC is presently limited by the beam-beam effect. To overcome this limitation, electron lenses will be installed in IR10. With the help of these devices, the headon beam-beam kick experienced during proton-proton collisions will be partially compensated, allowing for a larger beam-beam tuneshift at these collision points, and therefore increasing the luminosity. This will be accomplished by increasing the proton bunch intensity from the presently achieved 1.65 {center_dot} 10{sup 11} protons per bunch in 109 bunches per beam to 2.5 {center_dot} 10{sup 11}, thus roughly doubling the luminosity. In a further upgrade we aim for bunch intensities up to 3 {center_dot} 10{sup 11} protons per bunch. With RHIC originally being designed for a bunch intensity of 1 {center_dot} 10{sup 11} protons per bunch in 56 bunches, this six-fold increase in the total beam intensity by far exceeds the design parameters of the machine, and therefore potentially of its subsystems. In this note, we present a list of major subsystems that are of potential concern regarding this intensity upgrade, show their demonstrated performance at present intensities, and propose measures and beam experiments to study their readiness for the projected future intensities.

  4. Sea Floor Analyses Based On Multibeam Backscatter Strength

    Science.gov (United States)

    Beyer, A.

    Measurements of acoustic backscatter strength can be applied to analyse sea floor coverage on a spatial extent. They provide consistent coverage compared to analy- ses based on only a few surface samples. In particular the spatial validity of surface samples can be determined by analyses based on acoustic backscatter strength and sampling locations representative for the surrounding area can be determined. Dur- ing the cruise ANTXVII/4 of the German RV "Polarstern", a high precision swath bathymetry survey was performed along the European continental margin in the Por- cupine Seabight off southwest Ireland. Within the Porcupine Seabight a number of mound structures have been discovered earlier, most of them being carbonate mounds. The structure and genesis of these mounds are the main objective of recent investiga- tions. The cruise and the subsequent investigations are part of the EU project GEO- MOUND. They focus on the Belgica mound province. Besides the depth measure- ments, the acoustic intensities of the received echos have been recorded. Taking into account the transmitted and received sound level, acoustic beam patterns, and acous- tic attenuation in the water column, the backscatter strength of the ensonified area was calculated. This backscatter information is used to analyse the sea floor cover- age. Based on the data of the systematic survey the spatial variation of the backscatter strength was derived. Regions of equal backscatter characteristic can be combined and functions showing the dependency between backscatter strength and incidence angle of the acoustic wave can be determined. These functions help interpreting sea floor coverage. The mapping of the backscatter strength of the mound area indicates clear changes in backscatter strength. Small and shallow channels show a lower backscat- ter strength than their surroundings. That means the surface coverage of the channels is smooth with respect to the surroundings. One interpretation of this

  5. The construction of a high resolution crystal backscattering spectrometer HERMES I

    Energy Technology Data Exchange (ETDEWEB)

    Larese, J.Z.

    1998-11-01

    There is a need in the United States for a state-of-the-art, cold-neutron, crystal backscattering spectrometer (CBS) designed to investigate the structure and dynamics of condensed matter systems by the simultaneous utilization of long wavelength elastic diffraction and high-energy-resolution inelastic scattering. Cold neutron spectroscopy with CBS-type instruments has already made many important contributions to the study of atomic and molecular diffusion in biomaterials, polymers, semiconductors, liquid crystals, superionic conductors and the like. Such instruments have also been invaluable for ultra high resolution investigations of the low-lying quantum tunneling processes that provide direct insight into the dynamical response of solids at the lowest energies. Until relatively recently, however, all such instruments were located at steady-state reactors. This proposal describes HERMES I (High Energy Resolution Machines I) a CBS intended for installation at the LANSCE pulsed neutron facility of Los Alamos National Laboratory. As explained in detail in the main text, the authors propose to construct an updated, high-performance CBS which incorporates neutron techniques developed during the decade since IRIS was built, i.e., improved supermirror technology, a larger area crystal analyzer and high efficiency wire gas detectors. The instrument is designed in such a way as to be readily adaptable to future upgrades. HERMES I, they believe, will substantially expand the range and flexibility of neutron investigations in the United States and open new and potentially fruitful directions for condensed matter exploration. This document describes a implementation plan with a direct cost range between $4.5 to 5.6 M and scheduled duration of 39--45 months for identified alternatives.

  6. Effect of light backscattering on high-speed modulation performance in strongly injection-locked unidirectional semiconductor ring lasers

    Science.gov (United States)

    Smolyakov, Gennady A.; Osinski, Marek

    2014-03-01

    Greatly enhanced high-speed modulation performance has been recently predicted in numerical calculations for a novel injection-locking scheme involving a DBR or DFB master laser monolithically integrated with a unidirectional semiconductor microring laser. In this work, we investigate the effect of light backscattering between the two counterpropagating modes on high-speed modulation performance of strongly injection-locked unidirectional semiconductor microring lasers.

  7. The relationship between VHF radar auroral backscatter amplitude and Doppler velocity: a statistical study

    Directory of Open Access Journals (Sweden)

    B. A. Shand

    Full Text Available A statistical investigation of the relationship between VHF radar auroral backscatter intensity and Doppler velocity has been undertaken with data collected from 8 years operation of the Wick site of the Sweden And Britain Radar-auroral Experiment (SABRE. The results indicate three different regimes within the statistical data set; firstly, for Doppler velocities <200 m s–1, the backscatter intensity (measured in decibels remains relatively constant. Secondly, a linear relationship is observed between the backscatter intensity (in decibels and Doppler velocity for velocities between 200 m s–1 and 700 m s–1. At velocities greater than 700 m s–1 the backscatter intensity saturates at a maximum value as the Doppler velocity increases. There are three possible geophysical mechanisms for the saturation in the backscatter intensity at high phase speeds: a saturation in the irregularity turbulence level, a maximisation of the scattering volume, and a modification of the local ambient electron density. There is also a difference in the dependence of the backscatter intensity on Doppler velocity for the flow towards and away from the radar. The results for flow towards the radar exhibit a consistent relationship between backscatter intensity and measured velocities throughout the solar cycle. For flow away from the radar, however, the relationship between backscatter intensity and Doppler velocity varies during the solar cycle. The geometry of the SABRE system ensures that flow towards the radar is predominantly associated with the eastward electrojet, and flow away is associated with the westward electrojet. The difference in the backscatter intensity variation as a function of Doppler velocity is attributed to asymmetries between the eastward and westward electrojets and the geophysical parameters controlling the backscatter amplitude.

  8. Sea floor maps showing topography, sun-illuminated topography, and backscatter intensity of the Stellwagen Bank National Marine Sanctuary region off Boston, Massachusetts

    Science.gov (United States)

    Valentine, P.C.; Middleton, T.J.; Fuller, S.J.

    2000-01-01

    This data set contains the sea floor topographic contours, sun-illuminated topographic imagery, and backscatter intensity generated from a multibeam sonar survey of the Stellwagen Bank National Marine Sanctuary region off Boston, Massachusetts, an area of approximately 1100 square nautical miles. The Stellwagen Bank NMS Mapping Project is designed to provide detailed maps of the Stellwagen Bank region's environments and habitats and the first complete multibeam topographic and sea floor characterization maps of a significant region of the shallow EEZ. Data were collected on four cruises over a two year period from the fall of 1994 to the fall of 1996. The surveys were conducted aboard the Candian Hydrographic Service vessel Frederick G. Creed, a SWATH (Small Waterplane Twin Hull) ship that surveys at speeds of 16 knots. The multibeam data were collected utilizing a Simrad Subsea EM 1000 Multibeam Echo Sounder (95 kHz) that is permanently installed in the hull of the Creed.

  9. High Intensity Secondary Beams Driven by Protons

    CERN Document Server

    Galambos, John; Nagaitsev, Sergei

    2013-01-01

    As part of the Intensity Frontier effort within the 2013 Community Summer Study, a workshop on the proton machine capabilities was held (High Intensity Secondary Beams Driven by Proton Beams) April 17-20, 2013 at Brookhaven National Laboratory in Upton, NY. Primary aims of the workshop were to understand: 1) the beam requirements for proposed high intensity proton beam based measurements; 2) the capabilities of existing world-wide high power proton machines; 3) proton facility upgrade plans and proposals for new facilities; 4) and to document the R&D needs for proton accelerators and target systems needed to support proposed intensity frontier measurements. These questions are addressed in this summary.

  10. Relativistic electron mirrors from high intensity laser nanofoil interactions

    Energy Technology Data Exchange (ETDEWEB)

    Kiefer, Daniel

    2012-12-21

    studies allowed proceeding to the central goal, the demonstration of the relativistically flying mirror, which was achieved at the Astra Gemini dual beam laser facility. In this experiment, a frequency shift in the backscatter signal from the visible (800nm) to the extreme ultraviolet (∝60nm) was observed when irradiating the interaction region with a counter-propagating probe pulse simultaneously. Complementary to the experimental observations, a detailed numerical study on the dual beam interaction is presented, explaining the mirror formation and reflection process in great depth, indicating a >10{sup 4} fold increase in the backscatter efficiency as compared to the expected incoherent signal. The simulations show that the created electron mirrors propagate freely at relativistic velocities while reflecting off the counter-propagating laser, thereby truly acting like the relativistic mirror first discussed in Einstein's thought experiment. The reported work gives an intriguing insight into the electron dynamics in high intensity laser nanofoil interactions and constitutes a major step towards the coherent backscattering from a relativistic electron mirror of solid density, which could potentially generate bright bursts of X-rays on a micro-scale.

  11. Geometrically necessary dislocation densities in olivine obtained using high-angular resolution electron backscatter diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Wallis, David, E-mail: davidwa@earth.ox.ac.uk [Department of Earth Sciences, University of Oxford, South Parks Road, Oxford, Oxfordshire, OX1 3AN (United Kingdom); Hansen, Lars N. [Department of Earth Sciences, University of Oxford, South Parks Road, Oxford, Oxfordshire, OX1 3AN (United Kingdom); Ben Britton, T. [Department of Materials, Imperial College London, Royal School of Mines, Exhibition Road, London SW7 2AZ (United Kingdom); Wilkinson, Angus J. [Department of Materials, University of Oxford, Parks Road, Oxford, Oxfordshire, OX1 3PH (United Kingdom)

    2016-09-15

    Dislocations in geological minerals are fundamental to the creep processes that control large-scale geodynamic phenomena. However, techniques to quantify their densities, distributions, and types over critical subgrain to polycrystal length scales are limited. The recent advent of high-angular resolution electron backscatter diffraction (HR-EBSD), based on diffraction pattern cross-correlation, offers a powerful new approach that has been utilised to analyse dislocation densities in the materials sciences. In particular, HR-EBSD yields significantly better angular resolution (<0.01°) than conventional EBSD (~0.5°), allowing very low dislocation densities to be analysed. We develop the application of HR-EBSD to olivine, the dominant mineral in Earth's upper mantle by testing (1) different inversion methods for estimating geometrically necessary dislocation (GND) densities, (2) the sensitivity of the method under a range of data acquisition settings, and (3) the ability of the technique to resolve a variety of olivine dislocation structures. The relatively low crystal symmetry (orthorhombic) and few slip systems in olivine result in well constrained GND density estimates. The GND density noise floor is inversely proportional to map step size, such that datasets can be optimised for analysing either short wavelength, high density structures (e.g. subgrain boundaries) or long wavelength, low amplitude orientation gradients. Comparison to conventional images of decorated dislocations demonstrates that HR-EBSD can characterise the dislocation distribution and reveal additional structure not captured by the decoration technique. HR-EBSD therefore provides a highly effective method for analysing dislocations in olivine and determining their role in accommodating macroscopic deformation. - Highlights: • Lattice orientation gradients in olivine were measured using HR-EBSD. • The limited number of olivine slip systems enable simple least squares inversion for GND

  12. Species-Independent Modeling of High-Frequency Ultrasound Backscatter in Hyaline Cartilage.

    Science.gov (United States)

    Männicke, Nils; Schöne, Martin; Liukkonen, Jukka; Fachet, Dominik; Inkinen, Satu; Malo, Markus K; Oelze, Michael L; Töyräs, Juha; Jurvelin, Jukka S; Raum, Kay

    2016-06-01

    Apparent integrated backscatter (AIB) is a common ultrasound parameter used to assess cartilage matrix degeneration. However, the specific contributions of chondrocytes, proteoglycan and collagen to AIB remain unknown. To reveal these relationships, this work examined biopsies and cross sections of human, ovine and bovine cartilage with 40-MHz ultrasound biomicroscopy. Site-matched estimates of collagen concentration, proteoglycan concentration, collagen orientation and cell number density were employed in quasi-least-squares linear regression analyses to model AIB. A positive correlation (R(2) = 0.51, p 70°) to the sound beam direction. These findings indicate causal relationships between AIB and cartilage structural parameters and could aid in more sophisticated future interpretations of ultrasound backscatter. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. SPHERES, Jülich's high-flux neutron backscattering spectrometer at FRM II.

    Science.gov (United States)

    Wuttke, Joachim; Budwig, Alfred; Drochner, Matthias; Kämmerling, Hans; Kayser, Franz-Joseph; Kleines, Harald; Ossovyi, Vladimir; Pardo, Luis Carlos; Prager, Michael; Richter, Dieter; Schneider, Gerald J; Schneider, Harald; Staringer, Simon

    2012-07-01

    SPHERES is a third-generation neutron backscattering spectrometer, located at the 20 MW German neutron source FRM II and operated by the Jülich Centre for Neutron Science. It offers an energy resolution (fwhm) better than 0.65 μeV, a dynamic range of ± 31 μeV, and a signal-to-noise ratio of up to 1750:1.

  14. SPHERES, Juelich's high-flux neutron backscattering spectrometer at FRM II

    Energy Technology Data Exchange (ETDEWEB)

    Wuttke, Joachim; Budwig, Alfred; Drochner, Matthias; Kaemmerling, Hans; Kayser, Franz-Joseph; Kleines, Harald; Ossovyi, Vladimir; Pardo, Luis Carlos; Prager, Michael; Richter, Dieter; Schneider, Gerald J.; Schneider, Harald; Staringer, Simon [Forschungszentrum Juelich GmbH, 52425 Juelich (Germany)

    2012-07-15

    SPHERES is a third-generation neutron backscattering spectrometer, located at the 20 MW German neutron source FRM II and operated by the Juelich Centre for Neutron Science. It offers an energy resolution (fwhm) better than 0.65 {mu}eV, a dynamic range of {+-} 31 {mu}eV, and a signal-to-noise ratio of up to 1750:1.

  15. High intensity polarized electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Sinclair, C.K.

    1980-10-01

    The status of the polarized electron source development program at SLAC will be reviewed. Emission currents of 60 A, corresponding to a space charge limited current density of 180 A/cm/sup 2/, have been obtained from GaAs photocathodes. Electron beam polarization 20% greater than that obtainable from GaAs cathodes has been observed from multilayer GaAs-GaAlAs structures. Work in progress to produce high beam polarization from II-IV-V/sub 2/ chalcopyrite photocathodes will also be described.

  16. High-Intensity Proton Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jay L. Hirshfield

    2011-12-27

    Analysis is presented for an eight-cavity proton cyclotron accelerator that could have advantages as compared with other accelerators because of its potentially high acceleration gradient. The high gradient is possible since protons orbit in a sequence of TE111 rotating mode cavities of equally diminishing frequencies with path lengths during acceleration that greatly exceed the cavity lengths. As the cavities operate at sequential harmonics of a basic repetition frequency, phase synchronism can be maintained over a relatively wide injection phase window without undue beam emittance growth. It is shown that use of radial vanes can allow cavity designs with significantly smaller radii, as compared with simple cylindrical cavities. Preliminary beam transport studies show that acceptable extraction and focusing of a proton beam after cyclic motion in this accelerator should be possible. Progress is also reported on design and tests of a four-cavity electron counterpart accelerator for experiments to study effects on beam quality arising from variations injection phase window width. This device is powered by four 500-MW pulsed amplifiers at 1500, 1800, 2100, and 2400 MHz that provide phase synchronous outputs, since they are driven from a with harmonics derived from a phase-locked 300 MHz source.

  17. High Intensity Interval Training: New Insights

    Institute of Scientific and Technical Information of China (English)

    Martin J.Gibala

    2008-01-01

    @@ KEY POINTS ·High-intensity interval training(HIT)is characterized by repeated sessions of relatively brief,intermittent exercise.often performed with an“a11 out”effort or at an intensity close to that which elicits peak oxygen uptake(i.e.,≥90%of VO2 peak).

  18. High Intensity Exercise in Multiple Sclerosis

    DEFF Research Database (Denmark)

    Wens, Inez; Dalgas, Ulrik; Vandenabeele, Frank

    2015-01-01

    Introduction Low-to-moderate intensity exercise improves muscle contractile properties and endurance capacity in multiple sclerosis (MS). The impact of high intensity exercise remains unknown. Methods Thirty-four MS patients were randomized into a sedentary control group (SED, n = 11) and 2...

  19. Nakagami imaging for detecting thermal lesions induced by high-intensity focused ultrasound in tissue.

    Science.gov (United States)

    Rangraz, Parisa; Behnam, Hamid; Tavakkoli, Jahan

    2014-01-01

    High-intensity focused ultrasound induces focalized tissue coagulation by increasing the tissue temperature in a tight focal region. Several methods have been proposed to monitor high-intensity focused ultrasound-induced thermal lesions. Currently, ultrasound imaging techniques that are clinically used for monitoring high-intensity focused ultrasound treatment are standard pulse-echo B-mode ultrasound imaging, ultrasound temperature estimation, and elastography-based methods. On the contrary, the efficacy of two-dimensional Nakagami parametric imaging based on the distribution of the ultrasound backscattered signals to quantify properties of soft tissue has recently been evaluated. In this study, ultrasound radio frequency echo signals from ex vivo tissue samples were acquired before and after high-intensity focused ultrasound exposures and then their Nakagami parameter and scaling parameter of Nakagami distribution were estimated. These parameters were used to detect high-intensity focused ultrasound-induced thermal lesions. Also, the effects of changing the acoustic power of the high-intensity focused ultrasound transducer on the Nakagami parameters were studied. The results obtained suggest that the Nakagami distribution's scaling and Nakagami parameters can effectively be used to detect high-intensity focused ultrasound-induced thermal lesions in tissue ex vivo. These parameters can also be used to understand the degree of change in tissue caused by high-intensity focused ultrasound exposures, which could be interpreted as a measure of degree of variability in scatterer concentration in various parts of the high-intensity focused ultrasound lesion.

  20. High-intensity training in football.

    Science.gov (United States)

    Iaia, F Marcello; Rampinini, Ermanno; Bangsbo, Jens

    2009-09-01

    This article reviews the major physiological and performance effects of aerobic high-intensity and speed-endurance training in football, and provides insight on implementation of individual game-related physical training. Analysis and physiological measurements have revealed that modern football is highly energetically demanding, and the ability to perform repeated high-intensity work is of importance for the players. Furthermore, the most successful teams perform more high-intensity activities during a game when in possession of the ball. Hence, footballers need a high fitness level to cope with the physical demands of the game. Studies on football players have shown that 8 to 12 wk of aerobic high-intensity running training (> 85% HR(max)) leads to VO2(max) enhancement (5% to 11%), increased running economy (3% to 7%), and lower blood lactate accumulation during submaximal exercise, as well as improvements in the yo-yo intermittent recovery (YYIR) test performance (13%). Similar adaptations are observed when performing aerobic high-intensity training with small-sided games. Speed-endurance training has a positive effect on football-specific endurance, as shown by the marked improvements in the YYIR test (22% to 28%) and the ability to perform repeated sprints (approximately 2%). In conclusion, both aerobic and speed-endurance training can be used during the season to improve high-intensity intermittent exercise performance. The type and amount of training should be game related and specific to the technical, tactical, and physical demands imposed on each player.

  1. Experimental Observation of Generation of Superradiance Pulses in the Process of Backscattering of Pump Wave on the Intense Electron Bunch

    CERN Document Server

    Ginzburg, N S; Denisov, G G; Rozental, R M; Sergeev, A; Zotova, I V

    2005-01-01

    Recently significant progress was archived in the generation of multimegawatt subnanosecond pulses in millimeter wave band utilizing the cyclotron and Cherenkov mechanisms of superradiance (SR) [1,2]. We study the novel mechanism of SR when the powerful pumping wave undergoes the stimulated back scattering on the intense electron bunch. Due to the Doppler up shift the radiation frequency can significantly exceed the frequency of the pumping wave. With the relativistic microwave generator as a pumping wave source such a mechanism can be used for generation of the powerful pulse radiation in the short millimeter and submillimeter wave bands. Experiments on the observation of the stimulated scattering in the superradiance regime were carried out at Institute of Electrophysics RAS with two synchronized accelerators. The 4 ns electron beam from the first accelerator is used for generation of the 38 GHz 100 MW pumping wave which subsequently scattered on the subnanosecond 250 keV 1 kA electron bunch produced by the...

  2. Raman backscatter as a remote laser power sensor in high-energy-density plasmas

    CERN Document Server

    Moody, J D; Divol, L; Michel, P; Robey, H F; LePape, S; Ralph, J; Ross, J S; Glenzer, S H; Kirkwood, R K; Landen, O L; MacGowan, B J; Nikroo, A; Williams, E A

    2013-01-01

    Stimulated Raman backscatter (SRS) is used as a remote sensor to quantify the instantaneous laser power after transfer from outer to inner cones that cross in a National Ignition Facility (NIF) gas-filled hohlraum plasma. By matching SRS between a shot reducing outer vs a shot reducing inner power we infer that ~half of the incident outer-cone power is transferred to inner cones, for the specific time and wavelength configuration studied. This is the first instantaneous non-disruptive measure of power transfer in an indirect drive NIF experiment using optical measurements.

  3. NONINVASIVE MEASUREMENT OF LOCAL THERMAL DIFFUSIVITY USING BACKSCATTERED ULTRASOUND AND FOCUSED ULTRASOUND HEATING

    OpenAIRE

    2008-01-01

    Previously, noninvasive methods of estimating local tissue thermal and acoustic properties using backscattered ultrasound have been proposed in the literature. In this article, a noninvasive method of estimating local thermal diffusivity in situ during focused ultrasound heating using beamformed acoustic backscatter data and applying novel signal processing techniques is developed. A high intensity focused ultrasound (HIFU) transducer operating at subablative intensities is employed to create...

  4. Monte-Carlo simulations of a high-resolution backscattering spectrometer on the SNS - Long Wavelength Target Station

    Science.gov (United States)

    Bordallo, H. N.; Herwig, K. W.

    2001-03-01

    It is proposed to build an inverse geometry spectrometer to provide extremely high energy resolution (0.2 μeV FWHM, elastic) at the Long Wavelength Target Station (LWTS) at SNS. The design employs mica analyzers in close to backscattering geometry (final neutron wavelength of 20 ÅAnalytical calculations and Monte Carlo simulations (using the McStas package) have been used to optimize the layout of individual components and to estimate the instrument performance. This design requires a long initial guide section of 63 m from moderator to sample in order to achieve the timing resolution necessary for the desired δω. The LWTS will provide the high flux of long wavelength neutrons at the requisite pulse rate required by the spectrometer design. The resolution of this spectrometer lies between that routinely achieved by spin echo techniques and the design goal of the high power target station backscattering spectrometer. Covering this niche in energy resolution will allow systematic studies over the large dynamic range required by many disciplines. Molecular biology, for example, often requires systematic studies of many similar molecules under slightly different conditions, requiring a large range of energy/timing resolutions for optimum study.

  5. Analysis of forest backscattering characteristics based on polarization coherence tomography

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    It is difficult to make an inventory of vertical profiles of forest structure parameters in field measurements.However,analysis and understanding of forest backscattering characteristics contribute to estimation and detection of forest vertical structure because of the close relationships between backscattering characteristics and structure parameters.The vertical structure function in the complex interferometric coherence definition,which represents the vertical variation of microwave scattering with the penetration depth at a point in the 2-D radar image and can be used to analyze the forest backscattering characteristics,can be reconstructed from polarization coherence tomography(PCT).Based on PCT,the paper analyzes the forest backscattering characteristics and explores the inherent relationship between the result of PCT and the forest structure parameters from numerical simulation of Random Volume over Ground model(RVoG),Polarimetric SAR interferometry(PolInSAR)simulation of forest scene and PolInSAR data at L-band of the test site Traunstein.Firstly,the effects of the extinction coefficient and surface-to-volume scattering ratio in RVoG model on vertical backscattering characteristics are analyzed by means of numerical simulation.Secondly,by applying PCT to L-band POLInSAR simulations of forest scene,different variations of vertical backscattering due to different extinction coefficients and the ratios of surface-to-volume scattering resulting from different polarizations,forest types and densities are displayed and analyzed.Then a concept of relative average backscattering intensity is presented,and the factors which affect its vertical distribution are also discussed.Preliminary results show that there is high sensitivity of the vertical distribution of forest relative average backscattering intensity to the polarization,forest type and density.Finally,based on repeat pass DLR E-SAR L-band airborne POLInSAR data,the capability of PCT technology for detection

  6. Photoproduction at High Energy and High Intensity

    CERN Multimedia

    2002-01-01

    The photon beam used for this programme is tagged and provides a large flux up to very high energies (150-200 GeV). It is also hadron-free, since it is obtained by a two-step conversion method. A spectrometer is designed to exploit this beam and to perform a programme of photoproduction with a high level of sensitivity (5-50 events/picobarn).\\\\ \\\\ Priority will be given to the study of processes exhibiting the point-like behaviour of the photon, especially deep inelastic Compton scattering. The spectrometer has two magnets. Charged tracks are measured by MWPC's located only in field-free regions. Three calorimeters provide a large coverage for identifying and measuring electrons and photons. An iron filter downstream identifies muons. Most of the equipment is existing and recuperated from previous experiments.

  7. Photon spectrum and polarization for high conversion coefficient in the Compton backscattering process

    Science.gov (United States)

    Potylitsyn, A. P.; Kolchuzhkin, A. M.; Strikhanov, M. N.; Strokov, S. A.

    2017-07-01

    This study looks to simulate the nonlinear Compton backscattering (CBS) process based on the Monte Carlo technique for the conversion coefficient Kc ⩾ 1 , which can be considered as the average number of photons emitted by each electron. The characteristics of the nonlinear CBS process simulated in this work are as follows: the number of absorbed photons of a laser, the distance in the laser pulse in which the electron passes between two collisions, the energy and the polarization of the emitted photon in each collision, and the polarization of the electron before and after collision. The developed approach allows us to find the spectra and polarization characteristics of the final electrons and photons. When Kc > 1 , the spin-flip processes need to be considered for a correct simulation of the polarization of the final photons and electrons for energies typical of a γ- γ collider.

  8. Iterative, backscatter-analysis algorithms for increasing transmission and focusing light through highly-scattering random media

    CERN Document Server

    Jin, Curtis; Michielssen, Eric; Rand, Stephen

    2013-01-01

    Scattering hinders the passage of light through random media and consequently limits the usefulness of optical techniques for sensing and imaging. Thus, methods for increasing the transmission of light through such random media are of interest. Against this backdrop, Dorokhov, Pendry and others theoretically predicted the existence of a few highly transmitting eigen-wavefronts with transmission coefficients close to one in strongly backscattering random media. The breakthrough experiments of Vellekoop and Mosk confirmed the existence of these highly transmitting eigen-wavefronts and demonstrated that they could be discovered by using information from the far side of the scattering medium. Here, we numerically analyze this phenomenon in 2-D with fully spectrally accurate simulators and provide rigorous numerical evidence confirming the existence of these highly transmitting eigen-wavefronts in random media composed of hundreds of thousands of non-absorbing scatterers. We then develop physically realizable algo...

  9. High-intensity, focused ultrasonic fields

    DEFF Research Database (Denmark)

    Jensen, Leif Bjørnø

    1988-01-01

    distribution, etc. involving nonlinearity, diffraction, and absorption in the high-intensity focused ultrasonic fields produced by an ellipsoid as well as a spherical cap focusing geometry. Data from the development of an ESWL of the piezoelectric disk type are reported including demands to transducers...

  10. Cryogenic semiconductor high-intensity radiation monitors

    CERN Document Server

    Palmieri, V G; Borer, K; Casagrande, L; Da Vià, C; Devine, S R H; Dezillie, B; Esposito, A; Granata, V; Hauler, F; Jungermann, L; Li, Z; Lourenço, C; Niinikoski, T O; O'Shea, V

    2003-01-01

    This paper describes a novel technique to monitor high-intensity particle beams by means of a semiconductor detector. It consists of cooling a semiconductor detector down to cryogenic temperature to suppress the thermally generated leakage current and to precisely measure the integrated ionization signal. It will be shown that such a device provides very good linearity and a dynamic range wider than is possible with existing techniques. Moreover, thanks to the Lazarus effect, extreme radiation hardness can be achieved providing in turn absolute intensity measurements against precise calibration of the device at low beam flux.

  11. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  12. An FEL based high-intensity gamma source at the TESLA Test Facility at DESY

    CERN Document Server

    Pagani, C; Schneidmiller, E A; Yurkov, M V

    1999-01-01

    One possible extension of the FEL activity at DESY is connected with the installation of an additional FEL beamline providing tunable UV radiation with peak and average power of 220 GW and 7 kW, respectively. This report presents the feasibility study of a high-intensity, polarized, monochromatic gamma source at the TESLA Test Facility. Gamma quanta are produced in the process of Compton backscattering of the UV FEL radiation on 1 GeV electrons of the TTF accelerator. The ultimate intensity of the gamma source can reach a value up to 10 sup 1 sup 2 gamma quanta per second with a maximum energy of about 100 MeV. The energy resolution of the gamma source can be reduced down to a value of about 0.2%. Potential applications of the intense gamma source at the TESLA Test Facility are discussed as well.

  13. Narrowband inverse Compton scattering x-ray sources at high laser intensities

    CERN Document Server

    Seipt, D; Surzhykov, A; Fritzsche, S

    2014-01-01

    Narrowband x- and gamma-ray sources based on the inverse Compton scattering of laser pulses suffer from a limitation of the allowed laser intensity due to the onset of nonlinear effects that increase their bandwidth. It has been suggested that laser pulses with a suitable frequency modulation could compensate this ponderomotive broadening and reduce the bandwidth of the spectral lines, which would allow to operate narrowband Compton sources in the high-intensity regime. In this paper we, therefore, present the theory of nonlinear Compton scattering in a frequency modulated intense laser pulse. We systematically derive the optimal frequency modulation of the laser pulse from the scattering matrix element of nonlinear Compton scattering, taking into account the electron spin and recoil. We show that, for some particular scattering angle, an optimized frequency modulation completely cancels the ponderomotive broadening for all harmonics of the backscattered light. We also explore how sensitive this compensation ...

  14. New Insights into the Campeche Escarpment Post-Chicxulub Impact Using Multibeam Echo Sounder (MBES) Bathymetry and Backscatter Data

    Science.gov (United States)

    McBee, J.; Mitchell, G. A.; Brumley, K. J.; Gharib, J. J.; Paull, C. K.

    2016-12-01

    Multibeam Echo Sounder (MBES) bathymetry and backscatter data from the 2014 R/V Falkor survey are used to define the K-Pg boundary outcropping on the Campeche escarpment and to characterize large-scale erosional processes on the Campeche shelf. We delineate the escarpment into four geomorphic provinces based on submarine canyon density and morphology, as well as pronounced geomorphological differences formed in response to erosional processes along-strike of the Campeche Escarpment. Large-scale retrogressive-appearing erosion has left high-angle breaks where large slabs of sediment have eroded the escarpment edge, giving the slope a terraced appearance. This slab erosion reveals higher backscatter intensity material overlain with remnants of lower backscatter intensity sediments within the slide scar. We infer the high intensity backscatter material to be carbonate layers on which slab erosion occurred. The most prominent high-intensity backscatter layer is interpreted to be carbonate unit that identifies the K-Pg boundary layer previously reported by Paull et al. (2014) based on a steep bathymetric change and constrained by cores from DSDP Sites 86 and 94. Upslope, high intensity backscatter layers are inferred to represent post-impact carbonates that infilled the basin flank after the Chicxulub bolide impact. Lower intensity backscatter material is inferred to be fine-grained Cenozoic sediment drape. The stark contrast observed in MBES backscatter data between high intensity carbonate material and lower intensity sediments refines and constrains the location of the K-Pg boundary layer exposed along the Campeche escarpment and provides new insights into the carbonate platform post-bolide impact evolution as observed in the erosional styles of the Campeche escarpment.

  15. The high intensity neutron source FRANZ

    CERN Document Server

    Lederer, Claudia

    2014-01-01

    The Frankfurt neutron source of Stern Gerlach Zentrum FRANZ is currently under construction at the University of Frankfurt. At FRANZ, a high intensity neutron beam in the keV energy region will be produced by bombarding a $^7$Li target with a proton beam of several mA. These unprecedented high neutron fluxes will allow a number of neutron induced cross section measurements for the first time. Measurements can be performed by the time-of-flight and by the activation technique.

  16. Collective stimulated Brillouin backscatter

    CERN Document Server

    Lushnikov, Pavel M

    2007-01-01

    We develop the statistical theory of the stimulated Brillouin backscatter (BSBS) instability of a spatially and temporally partially incoherent laser beam for laser fusion relevant plasma. We find a new regime of BSBS which has a much larger threshold than the classical threshold of a coherent beam in long-scale-length laser fusion plasma. Instability is collective because it does not depend on the dynamics of isolated speckles of laser intensity, but rather depends on averaged beam intensity. We identify convective and absolute instability regimes. Well above the incoherent threshold the coherent instability growth rate is recovered. The threshold of convective instability is inside the typical parameter region of National Ignition Facility (NIF) designs although current NIF bandwidth is not large enough to insure dominance of collective instability and suggests lower instability threshold due to speckle contribution. In contrast, we estimate that the bandwidth of KrF-laser-based fusion systems would be larg...

  17. High intensity specular reflectometry - first experiments

    CERN Document Server

    Stahn, J; Panzner, T

    2011-01-01

    Selene is the attempt to implement a new scheme for high-intensity specular reflectometry. Instead of a highly collimated beam one uses a convergent beam covering a large angular range. The angular resolution is then performed by a position-sensitive detector. Off-specular scattering in this set-up leads to some background, but for screening of wide parameter ranges (e.g. temperature, electric and magnetic fields) the intensity gain of at least one order of magnitude is essential. If necessary, the high precession measurements (even with off-specular components) then are performed with the conventional set-up. The heart of this new set-up is an elliptically focusing guide element of 2\\,m length. Though this guide is optimised for the use on the TOF reflectometer Amor at SINQ, it can be used as stand-alone device to check the possible application also for other neutron scattering techniques. The first measurements on AMOR confirmed the general concept and the various operation modes. A draw-back occurred due t...

  18. Estimation of size of red blood cell aggregates using backscattering property of high-frequency ultrasound: In vivo evaluation

    Science.gov (United States)

    Kurokawa, Yusaku; Taki, Hirofumi; Yashiro, Satoshi; Nagasawa, Kan; Ishigaki, Yasushi; Kanai, Hiroshi

    2016-07-01

    We propose a method for assessment of the degree of red blood cell (RBC) aggregation using the backscattering property of high-frequency ultrasound. In this method, the scattering property of RBCs is extracted from the power spectrum of RBC echoes normalized by that from the posterior wall of a vein. In an experimental study using a phantom, employing the proposed method, the sizes of microspheres 5 and 20 µm in diameter were estimated to have mean values of 4.7 and 17.3 µm and standard deviations of 1.9 and 1.4 µm, respectively. In an in vivo experimental study, we compared the results between three healthy subjects and four diabetic patients. The average estimated scatterer diameters in healthy subjects at rest and during avascularization were 7 and 28 µm, respectively. In contrast, those in diabetic patients receiving both antithrombotic therapy and insulin therapy were 11 and 46 µm, respectively. These results show that the proposed method has high potential for clinical application to assess RBC aggregation, which may be related to the progress of diabetes.

  19. Reduced Brillouin backscatter in CO2 laser-target interaction

    Science.gov (United States)

    Ng, A.; Offenberger, A. A.; Karttunen, S. J.

    1981-02-01

    A substantially reduced Brillouin reflection has been found for CO2 laser-irradiated high-density gas targets. In contrast to the high reflectivity (60%) previously observed for underdense hydrogen plasma, total backscatter (stimulated plus specular) is found to peak at 30% for incident intensity 5 times 10 to the twelfth W per square centimeter and decrease thereafter to 18% at 10 to the thirteenth W per square centimeter. The ponderomotive effects are postulated to account for these observations.

  20. A Coherent Compton Backscattering High Gain FEL using an X-Band Microwave Undulator

    Energy Technology Data Exchange (ETDEWEB)

    Tantawi, S.; Dolgashev, V.; Nantista, C.; /SLAC; Pellegrini, C.; Rosenzweig, J.; Travish, G.; /UCLA

    2005-12-14

    High power microwave sources at X-Band, delivering 400 to 500 of megawatts for about 400 ns, have been recently developed. These sources can power a microwave undulator with short period and large gap, and can be used in short wavelength FELs reaching the nm region at a beam energy of about 1 GeV. We present here an experiment designed to demonstrate that microwave undulators have the field quality needed for high gain FELs.

  1. High Intensity High Charge State ECR Ion Sources

    CERN Document Server

    Leitner, Daniela

    2005-01-01

    The next-generation heavy ion beam accelerators such as the proposed Rare Isotope Accelerator (RIA), the Radioactive Ion Beam Factory at RIKEN, the GSI upgrade project, the LHC-upgrade, and IMP in Lanzhou require a great variety of high charge state ion beams with a magnitude higher beam intensity than currently achievable. High performance Electron Cyclotron Resonance (ECR) ion sources can provide the flexibility since they can routinely produce beams from hydrogen to uranium. Over the last three decades, ECR ion sources have continued improving the available ion beam intensities by increasing the magnetic fields and ECR heating frequencies to enhance the confinement and the plasma density. With advances in superconducting magnet technology, a new generation of high field superconducting sources is now emerging, designed to meet the requirements of these next generation accelerator projects. The talk will briefly review the field of high performance ECR ion sources and the latest developments for high intens...

  2. Cavitation inception by the backscattering of pressure waves from a bubble interface

    Science.gov (United States)

    Takahira, Hiroyuki; Ogasawara, Toshiyuki; Mori, Naoto; Tanaka, Moe

    2015-10-01

    The secondary cavitation that occurs by the backscattering of focused ultrasound from a primary cavitation bubble caused by the negative pressure part of the ultrasound (Maxwell, et al., 2011) might be useful for the energy exchange due to bubble oscillations in High Intensity Focused Ultrasound (HIFU). The present study is concerned with the cavitation inception by the backscattering of ultrasound from a bubble. In the present experiment, a laser-induced bubble which is generated by a pulsed focused laser beam with high intensity is utilized as a primary cavitation bubble. After generating the bubble, focused ultrasound is emitted to the bubble. The acoustic field and the bubble motion are observed with a high-speed video camera. It is confirmed that the secondary cavitation bubble clouds are generated by the backscattering from the laser-induced bubble. The growth of cavitation bubble clouds is analyzed with the image processing method. The experimental results show that the height and width of the bubble clouds grow in stepwise during their evolution. The direct numerical simulations are also conducted for the backscattering of incident pressure waves from a bubble in order to evaluate a pressure field near the bubble. It is shown that the ratio of a bubble collapse time t0 to a characteristic time of wave propagation tS, η = t0/ts, is an important determinant for generating negative pressure region by backscattering. The minimum pressure location by the backscattering in simulations is in good agreement with the experiment.

  3. Quantitative ultrasound imaging for monitoring in situ high-intensity focused ultrasound exposure.

    Science.gov (United States)

    Ghoshal, Goutam; Kemmerer, Jeremy P; Karunakaran, Chandra; Abuhabsah, Rami; Miller, Rita J; Sarwate, Sandhya; Oelze, Michael L

    2014-10-01

    Quantitative ultrasound (QUS) imaging is hypothesized to map temperature elevations induced in tissue with high spatial and temporal resolution. To test this hypothesis, QUS techniques were examined to monitor high-intensity focused ultrasound (HIFU) exposure of tissue. In situ experiments were conducted on mammary adenocarcinoma tumors grown in rats and lesions were formed using a HIFU system. A thermocouple was inserted into the tumor to provide estimates of temperature at one location. Backscattered time-domain waveforms from the tissue during exposure were recorded using a clinical ultrasonic imaging system. Backscatter coefficients were estimated using a reference phantom technique. Two parameters were estimated from the backscatter coefficient (effective scatterer diameter (ESD) and effective acoustic concentration (EAC). The changes in the average parameters in the regions corresponding to the HIFU focus over time were correlated to the temperature readings from the thermocouple. The changes in the EAC parameter were consistently correlated to temperature during both heating and cooling of the tumors. The changes in the ESD did not have a consistent trend with temperature. The mean ESD and EAC before exposure were 120 ± 16 μm and 32 ± 3 dB/cm3, respectively, and changed to 144 ± 9 μm and 51 ± 7 dB/cm3, respectively, just before the last HIFU pulse was delivered to the tissue. After the tissue cooled down to 37 °C, the mean ESD and EAC were 126 ± 8 μm and 35 ± 4 dB/cm3, respectively. Peak temperature in the range of 50-60 °C was recorded by a thermocouple placed just behind the tumor. These results suggest that QUS techniques have the potential to be used for non-invasive monitoring of HIFU exposure.

  4. High intensity neutrino oscillation facilities in Europe

    CERN Document Server

    Edgecock, T R; Davenne, T; Densham, C; Fitton, M; Kelliher, D; Loveridge, P; Machida, S; Prior, C; Rogers, C; Rooney, M; Thomason, J; Wilcox, D; Wildner, E; Efthymiopoulos, I; Garoby, R; Gilardoni, S; Hansen, C; Benedetto, E; Jensen, E; Kosmicki, A; Martini, M; Osborne, J; Prior, G; Stora, T; Melo-Mendonca, T; Vlachoudis, V; Waaijer, C; Cupial, P; Chancé, A; Longhin, A; Payet, J; Zito, M; Baussan, E; Bobeth, C; Bouquerel, E; Dracos, M; Gaudiot, G; Lepers, B; Osswald, F; Poussot, P; Vassilopoulos, N; Wurtz, J; Zeter, V; Bielski, J; Kozien, M; Lacny, L; Skoczen, B; Szybinski, B; Ustrycka, A; Wroblewski, A; Marie-Jeanne, M; Balint, P; Fourel, C; Giraud, J; Jacob, J; Lamy, T; Latrasse, L; Sortais, P; Thuillier, T; Mitrofanov, S; Loiselet, M; Keutgen, Th; Delbar, Th; Debray, F; Trophine, C; Veys, S; Daversin, C; Zorin, V; Izotov, I; Skalyga, V; Burt, G; Dexter, A C; Kravchuk, V L; Marchi, T; Cinausero, M; Gramegna, F; De Angelis, G; Prete, G; Collazuol, G; Laveder, M; Mazzocco, M; Mezzetto, M; Signorini, C; Vardaci, E; Di Nitto, A; Brondi, A; La Rana, G; Migliozzi, P; Moro, R; Palladino, V; Gelli, N; Berkovits, D; Hass, M; Hirsh, T Y; Schaumann, M; Stahl, A; Wehner, J; Bross, A; Kopp, J; Neuffer, D; Wands, R; Bayes, R; Laing, A; Soler, P; Agarwalla, S K; Villanueva, A Cervera; Donini, A; Ghosh, T; Cadenas, J J Gómez; Hernández, P; Martín-Albo, J; Mena, O; Burguet-Castell, J; Agostino, L; Buizza-Avanzini, M; Marafini, M; Patzak, T; Tonazzo, A; Duchesneau, D; Mosca, L; Bogomilov, M; Karadzhov, Y; Matev, R; Tsenov, R; Akhmedov, E; Blennow, M; Lindner, M; Schwetz, T; Martinez, E Fernández; Maltoni, M; Menéndez, J; Giunti, C; García, M C González; Salvado, J; Coloma, P; Huber, P; Li, T; López-Pavón, J; Orme, C; Pascoli, S; Meloni, D; Tang, J; Winter, W; Ohlsson, T; Zhang, H; Scotto-Lavina, L; Terranova, F; Bonesini, M; Tortora, L; Alekou, A; Aslaninejad, M; Bontoiu, C; Kurup, A; Jenner, L J; Long, K; Pasternak, J; Pozimski, J; Back, J J; Harrison, P; Beard, K; Bogacz, A; Berg, J S; Stratakis, D; Witte, H; Snopok, P; Bliss, N; Cordwell, M; Moss, A; Pattalwar, S; Apollonio, M

    2013-01-01

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the ph...

  5. High intensity neutrino oscillation facilities in Europe

    CERN Document Server

    Edgecock, T.R.; Davenne, T.; Densham, C.; Fitton, M.; Kelliher, D.; Loveridge, P.; Machida, S.; Prior, C.; Rogers, C.; Rooney, M.; Thomason, J.; Wilcox, D.; Wildner, E.; Efthymiopoulos, I.; Garoby, R.; Gilardoni, S.; Hansen, C.; Benedetto, E.; Jensen, E.; Kosmicki, A.; Martini, M.; Osborne, J.; Prior, G.; Stora, T.; Melo-Mendonca, T.; Vlachoudis, V.; Waaijer, C.; Cupial, P.; Chancé, A.; Longhin, A.; Payet, J.; Zito, M.; Baussan, E.; Bobeth, C.; Bouquerel, E.; Dracos, M.; Gaudiot, G.; Lepers, B.; Osswald, F.; Poussot, P.; Vassilopoulos, N.; Wurtz, J.; Zeter, V.; Bielski, J.; Kozien, M.; Lacny, L.; Skoczen, B.; Szybinski, B.; Ustrzycka, A.; Wroblewski, A.; Marie-Jeanne, M.; Balint, P.; Fourel, C.; Giraud, J.; Jacob, J.; Lamy, T.; Latrasse, L.; Sortais, P.; Thuillier, T.; Mitrofanov, S.; Loiselet, M.; Keutgen, Th.; Delbar, Th.; Debray, F.; Trophine, C.; Veys, S.; Daversin, C.; Zorin, V.; Izotov, I.; Skalyga, V.; Burt, G.; Dexter, A.C.; Kravchuk, V.L.; Marchi, T.; Cinausero, M.; Gramegna, F.; De Angelis, G.; Prete, G.; Collazuol, G.; Laveder, M.; Mazzocco, M.; Mezzetto, M.; Signorini, C.; Vardaci, E.; Di Nitto, A.; Brondi, A.; La Rana, G.; Migliozzi, P.; Moro, R.; Palladino, V.; Gelli, N.; Berkovits, D.; Hass, M.; Hirsh, T.Y.; Schaumann, M.; Stahl, A.; Wehner, J.; Bross, A.; Kopp, J.; Neuffer, D.; Wands, R.; Bayes, R.; Laing, A.; Soler, P.; Agarwalla, S.K.; Cervera Villanueva, A.; Donini, A.; Ghosh, T.; Gómez Cadenas, J.J.; Hernández, P.; Martín-Albo, J.; Mena, O.; Burguet-Castell, J.; Agostino, L.; Buizza-Avanzini, M.; Marafini, M.; Patzak, T.; Tonazzo, A.; Duchesneau, D.; Mosca, L.; Bogomilov, M.; Karadzhov, Y.; Matev, R.; Tsenov, R.; Akhmedov, E.; Blennow, M.; Lindner, M.; Schwetz, T.; Fernández Martinez, E.; Maltoni, M.; Menéndez, J.; Giunti, C.; González García, M. C.; Salvado, J.; Coloma, P.; Huber, P.; Li, T.; López-Pavón, J.; Orme, C.; Pascoli, S.; Meloni, D.; Tang, J.; Winter, W.; Ohlsson, T.; Zhang, H.; Scotto-Lavina, L.; Terranova, F.; Bonesini, M.; Tortora, L.; Alekou, A.; Aslaninejad, M.; Bontoiu, C.; Kurup, A.; Jenner, L.J.; Long, K.; Pasternak, J.; Pozimski, J.; Back, J.J.; Harrison, P.; Beard, K.; Bogacz, A.; Berg, J.S.; Stratakis, D.; Witte, H.; Snopok, P.; Bliss, N.; Cordwell, M.; Moss, A.; Pattalwar, S.; Apollonio, M.

    2013-02-20

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the ph...

  6. High intensity neutrino oscillation facilities in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Edgecock, T. R.; Caretta, O.; Davenne, T.; Densam, C.; Fitton, M.; Kelliher, D.; Loveridge, P.; Machida, S.; Prior, C.; Rogers, C.; Rooney, M.; Thomason, J.; Wilcox, D.; Wildner, E.; Efthymiopoulos, I.; Garoby, R.; Gilardoni, S.; Hansen, C.; Benedetto, E.; Jensen, E.; Kosmicki, A.; Martini, M.; Osborne, J.; Prior, G.; Stora, T.; Melo Mendonca, T.; Vlachoudis, V.; Waaijer, C.; Cupial, P.; Chancé, A.; Longhin, A.; Payet, J.; Zito, M.; Baussan, E.; Bobeth, C.; Bouquerel, E.; Dracos, M.; Gaudiot, G.; Lepers, B.; Osswald, F.; Poussot, P.; Vassilopoulos, N.; Wurtz, J.; Zeter, V.; Bielski, J.; Kozien, M.; Lacny, L.; Skoczen, B.; Szybinski, B.; Ustrycka, A.; Wroblewski, A.; Marie-Jeanne, M.; Balint, P.; Fourel, C.; Giraud, J.; Jacob, J.; Lamy, T.; Latrasse, L.; Sortais, P.; Thuillier, T.; Mitrofanov, S.; Loiselet, M.; Keutgen, Th.; Delbar, Th.; Debray, F.; Trophine, C.; Veys, S.; Daversin, C.; Zorin, V.; Izotov, I.; Skalyga, V.; Burt, G.; Dexter, A. C.; Kravchuk, V. L.; Marchi, T.; Cinausero, M.; Gramegna, F.; De Angelis, G.; Prete, G.; Collazuol, G.; Laveder, M.; Mazzocco, M.; Mezzetto, M.; Signorini, C.; Vardaci, E.; Di Nitto, A.; Brondi, A.; La Rana, G.; Migliozzi, P.; Moro, R.; Palladino, V.; Gelli, N.; Berkovits, D.; Hass, M.; Hirsh, T. Y.; Schaumann, M.; Stahl, A.; Wehner, J.; Bross, A.; Kopp, J.; Neuffer, D.; Wands, R.; Bayes, R.; Laing, A.; Soler, P.; Agarwalla, S. K.; Cervera Villanueva, A.; Donini, A.; Ghosh, T.; Gómez Cadenas, J. J.; Hernández, P.; Martín-Albo, J.; Mena, O.; Burguet-Castell, J.; Agostino, L.; Buizza-Avanzini, M.; Marafini, M.; Patzak, T.; Tonazzo, A.; Duchesneau, D.; Mosca, L.; Bogomilov, M.; Karadzhov, Y.; Matev, R.; Tsenov, R.; Akhmedov, E.; Blennow, M.; Lindner, M.; Schwetz, T.; Fernández Martinez, E.; Maltoni, M.; Menéndez, J.; Giunti, C.; González García, M. C.; Salvado, J.; Coloma, P.; Huber, P.; Li, T.; López Pavón, J.; Orme, C.; Pascoli, S.; Meloni, D.; Tang, J.; Winter, W.; Ohlsson, T.; Zhang, H.; Scotto-Lavina, L.; Terranova, F.; Bonesini, M.; Tortora, L.; Alekou, A.; Aslaninejad, M.; Bontoiu, C.; Kurup, A.; Jenner, L. J.; Long, K.; Pasternak, J.; Pozimski, J.; Back, J. J.; Harrison, P.; Beard, K.; Bogacz, A.; Berg, J. S.; Stratakis, D.; Witte, H.; Snopok, P.; Bliss, N.; Cordwell, M.; Moss, A.; Pattalwar, S.; Apollonio, M.

    2013-02-01

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.

  7. High-intensity sweeteners and energy balance.

    Science.gov (United States)

    Swithers, Susan E; Martin, Ashley A; Davidson, Terry L

    2010-04-26

    Recent epidemiological evidence points to a link between a variety of negative health outcomes (e.g. metabolic syndrome, diabetes and cardiovascular disease) and the consumption of both calorically sweetened beverages and beverages sweetened with high-intensity, non-caloric sweeteners. Research on the possibility that non-nutritive sweeteners promote food intake, body weight gain, and metabolic disorders has been hindered by the lack of a physiologically-relevant model that describes the mechanistic basis for these outcomes. We have suggested that based on Pavlovian conditioning principles, consumption of non-nutritive sweeteners could result in sweet tastes no longer serving as consistent predictors of nutritive postingestive consequences. This dissociation between the sweet taste cues and the caloric consequences could lead to a decrease in the ability of sweet tastes to evoke physiological responses that serve to regulate energy balance. Using a rodent model, we have found that intake of foods or fluids containing non-nutritive sweeteners was accompanied by increased food intake, body weight gain, accumulation of body fat, and weaker caloric compensation, compared to consumption of foods and fluids containing glucose. Our research also provided evidence consistent with the hypothesis that these effects of consuming saccharin may be associated with a decrement in the ability of sweet taste to evoke thermic responses, and perhaps other physiological, cephalic phase, reflexes that are thought to help maintain energy balance.

  8. Physics of intense, high energy radiation effects.

    Energy Technology Data Exchange (ETDEWEB)

    Hjalmarson, Harold Paul; Hartman, E. Frederick; Magyar, Rudolph J.; Crozier, Paul Stewart

    2011-02-01

    This document summarizes the work done in our three-year LDRD project titled 'Physics of Intense, High Energy Radiation Effects.' This LDRD is focused on electrical effects of ionizing radiation at high dose-rates. One major thrust throughout the project has been the radiation-induced conductivity (RIC) produced by the ionizing radiation. Another important consideration has been the electrical effect of dose-enhanced radiation. This transient effect can produce an electromagnetic pulse (EMP). The unifying theme of the project has been the dielectric function. This quantity contains much of the physics covered in this project. For example, the work on transient electrical effects in radiation-induced conductivity (RIC) has been a key focus for the work on the EMP effects. This physics in contained in the dielectric function, which can also be expressed as a conductivity. The transient defects created during a radiation event are also contained, in principle. The energy loss lead the hot electrons and holes is given by the stopping power of ionizing radiation. This information is given by the inverse dielectric function. Finally, the short time atomistic phenomena caused by ionizing radiation can also be considered to be contained within the dielectric function. During the LDRD, meetings about the work were held every week. These discussions involved theorists, experimentalists and engineers. These discussions branched out into the work done in other projects. For example, the work on EMP effects had influence on another project focused on such phenomena in gases. Furthermore, the physics of radiation detectors and radiation dosimeters was often discussed, and these discussions had impact on related projects. Some LDRD-related documents are now stored on a sharepoint site (https://sharepoint.sandia.gov/sites/LDRD-REMS/default.aspx). In the remainder of this document the work is described in catergories but there is much overlap between the atomistic

  9. High intensity neutrino oscillation facilities in Europe

    Directory of Open Access Journals (Sweden)

    T. R. Edgecock

    2013-02-01

    Full Text Available The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ^{+} and μ^{-} beams in a storage ring. The far detector in this case is a 100 kt magnetized iron neutrino detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular ^{6}He and ^{18}Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.

  10. High-Intensity, High Charge-State Heavy Ion Sources

    CERN Document Server

    Alessi, J

    2004-01-01

    There are many accelerator applications for high intensity heavy ion sources, with recent needs including dc beams for RIA, and pulsed beams for injection into synchrotrons such as RHIC and LHC. The present status of sources producing high currents of high charge state heavy ions will be reviewed. These sources include ECR, EBIS, and Laser ion sources. The benefits and limitations for these type sources will be described, for both dc and pulsed applications. Possible future improvements in these type sources will also be discussed.

  11. Development and characterization of a blood mimicking fluid for high intensity focused ultrasound.

    Science.gov (United States)

    Liu, Yunbo; Maruvada, Subha; King, Randy L; Herman, Bruce A; Wear, Keith A

    2008-09-01

    A blood mimicking fluid (BMF) has been developed for the acoustic and thermal characterizations of high intensity focused ultrasound (HIFU) ablation devices. The BMF is based on a degassed and de-ionized water solution dispersed with low density polyethylene microspheres, nylon particles, gellan gum, and glycerol. A broad range of physical parameters, including attenuation coefficient, speed of sound, viscosity, thermal conductivity, and diffusivity, were characterized as a function of temperature (20-70 degrees C). The nonlinear parameter B/A and backscatter coefficient were also measured at room temperature. Importantly, the attenuation coefficient is linearly proportional to the frequency (2-8 MHz) with a slope of about 0.2 dB cm(-1) MHz(-1) in the 20-70 degrees C range as in the case of human blood. Furthermore, sound speed and bloodlike backscattering indicate the usefulness of the BMF for ultrasound flow imaging and ultrasound-guided HIFU applications. Most of the other temperature-dependent physical parameters are also close to the reported values in human blood. These properties make it a unique HIFU research tool for developing standardized exposimetry techniques, validating numerical models, and determining the safety and efficacy of HIFU ablation devices.

  12. The role of dislocations in varied olivine deformation mechanisms investigated using high-angular resolution electron backscatter diffraction

    Science.gov (United States)

    Wallis, David; Hansen, Lars; Britton, Ben; Wilkinson, Angus

    2016-04-01

    Experimentally-derived flow laws can be used to predict the rheology of rocks deformed under natural conditions only if the same microphysical processes can be demonstrated to control the rate-limiting deformation mechanism in both cases. Olivine rheology may exert a principle control on the strength of the lithosphere, and therefore considerable research effort has been applied to assessing its rheology through experimental, geological, and geophysical approaches. Nonetheless, considerable uncertainty remains regarding the dominant deformation mechanisms in the upper mantle. This uncertainty arises in large part due to our limited understanding of the fundamental deformation processes associated with each mechanism. Future improvements to microphysical models of distinct deformation mechanisms require new insight into the contributions those fundamental processes to the macroscopic behaviour. The dynamics of dislocations is central to modelling viscous deformation of olivine, but characterisation techniques capable of constraining dislocation types, densities, and distributions over the critical grain to polycrystal length-scales have been lacking. High angular resolution electron backscatter diffraction (HR-EBSD), developed and increasingly applied in the material sciences, offers an approach capable of such analyses. HR-EBSD utilises diffraction pattern image cross-correlation to achieve dramatically improved angular resolution (~0.01°) of lattice orientation gradients compared to conventional Hough-based EBSD (~0.5°). This angular resolution allows very low densities (≥ 10^11 m^-2) of geometrically necessary dislocations (GND) to be resolved, facilitating analysis of a wide range of dislocation microstructures. We have developed the application of HR-EBSD to olivine and applied it to samples deformed both experimentally and naturally in grain-size sensitive and grain-size insensitive regimes. The results quantitatively highlight variations in the types and

  13. High-Intensity Synchrotron Radiation Effects

    CERN Document Server

    Suetsugu, Y

    2016-01-01

    Various effects of intense synchrotron radiation on the performance of particle accelerators, especially for storage rings, are discussed. Following a brief introduction to synchrotron radiation, the basic concepts of heat load, gas load, electron emission, and the countermeasures against these effects are discussed.

  14. Stretching Effects: High-intensity & Moderate-duration vs. Low-intensity & Long-duration.

    Science.gov (United States)

    Freitas, S R; Vaz, J R; Bruno, P M; Andrade, R; Mil-Homens, P

    2016-03-01

    This study examined whether a high-intensity, moderate-duration bout of stretching would produce the same acute effects as a low-intensity, long-duration bout of stretching. 17 volunteers performed 2 knee-flexor stretching protocols: a high-intensity stretch (i. e., 100% of maximum tolerable passive torque) with a moderate duration (243.5 ± 69.5-s); and a low-intensity stretch (50% of tolerable passive torque) with a long duration (900-s). Passive torque at a given sub-maximal angle, peak passive torque, maximal range of motion (ROM), and muscle activity were assessed before and after each stretching protocol (at intervals of 1, 30 and 60 min). The maximal ROM and tolerable passive torque increased for all time points following the high-intensity stretching (p0.05). 1 min post-stretching, the passive torque decreased in both protocols, but to a greater extent in the low-intensity protocol. 30 min post-test, torque returned to baseline for the low-intensity protocol and had increased above the baseline for the high-intensity stretches. The following can be concluded: 1) High-intensity stretching increases the maximal ROM and peak passive torque compared to low-intensity stretching; 2) low-intensity, long-duration stretching is the best way to acutely decrease passive torque; and 3) high-intensity, moderate-duration stretching increases passive torque above the baseline 30 min after stretching. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Analytical calculations and Monte-Carlo simulations of a high-resolution backscattering spectrometer for the long wavelength target station at the Spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Bordallo, H.N. E-mail: bordallo@hmi.de; Herwig, K.W.; Zsigmond, G

    2002-09-21

    Using the Monte-Carlo simulation programs McStas and VITESS, we present the design principles of the proposed high-resolution inverse geometry spectrometer on the Spallation neutron source (SNS) - long wavelength target station (LWTS). LWTS will enable the combination of large energy and momentum transfer ranges with energy resolution. Indeed the resolution of this spectrometer lie between that routinely achieved by spin echo techniques and the design goal of the high-power target station (HPTS) backscattering spectrometer. This niche of energy resolution is interesting for the study of slow motions of large objects and we are led to the domain of large molecules - polymers and biological molecules.

  16. Analytical calculations and Monte-Carlo simulations of a high-resolution backscattering spectrometer for the long wavelength target station at the Spallation neutron source

    CERN Document Server

    Bordallo, H N; Zsigmond, G

    2002-01-01

    Using the Monte-Carlo simulation programs McStas and VITESS, we present the design principles of the proposed high-resolution inverse geometry spectrometer on the Spallation neutron source (SNS) - long wavelength target station (LWTS). LWTS will enable the combination of large energy and momentum transfer ranges with energy resolution. Indeed the resolution of this spectrometer lie between that routinely achieved by spin echo techniques and the design goal of the high-power target station (HPTS) backscattering spectrometer. This niche of energy resolution is interesting for the study of slow motions of large objects and we are led to the domain of large molecules - polymers and biological molecules.

  17. The contribution of bubbles to high-frequency sea surface backscatter: a 24-h time series of field measurements.

    Science.gov (United States)

    Dahl, Peter H

    2003-02-01

    Measurements of acoustic sea surface backscattering, wind speed, and surface wave spectra were made continually over a 24-h period in an experiment conducted in 26 m of water near the Dry Tortugus collection of islands off south Florida in February 1995. The backscattering measurements were made at a frequency of 30 kHz and a sea surface grazing angle of 20 degrees; a time series of the decibel equivalent of this variable, called SS20, was studied in terms of its dependence on environmental variables. On occasion reliable estimates of scattering in the grazing range 15 degrees-27 degrees were also obtained during the 24 hours. The scattering data exhibited evidence, in terms of scattering level and grazing angle dependence, of scattering from near-surface bubbles rather than scattering from the rough air-sea interface. The scattering data were compared with a model for sigma(b), the apparent backscattering cross section per unit area due to bubble scattering, that is driven by a parameter, beta1, equal to the depth-integrated extinction cross section per unit volume. Using an empirical model for beta1 based on data from a 1977 experiment conducted in pelagic waters, model predictions agreed reasonably well with the 1995 measurements presented here. Additional model-data comparisons were made using four measurements from a 1992 experiment conducted in pelagic waters. Finally, the 24-h time series of acoustic scattering exhibited a hysteresis effect, wherein for a given wind speed, there was a tendency for the scattering level to be higher if prior winds had been falling. A better understanding of this effect is essential to reduce uncertainty in model predictions.

  18. Is high-intensity exercise better than moderate-intensity exercise for weight loss?

    Science.gov (United States)

    De Feo, P

    2013-11-01

    This viewpoint debates the state-of-the-art research focusing on the optimal intensity of the exercise programs for inducing a sustained weight or fat-mass loss in overweight/obese people. In our demanding society, the most attractive messages in the popular press are those promising the best results in a short time. This might explain the emphasis given by media to those scientific articles that report the efficacy on weight loss of exercise programs by their shorter duration and higher intensity. However, in the literature on overweight or obese people, there is little conclusive evidence for more favorable effects with high-intensity training than with continuous moderate-intensity exercise on body weight or fat mass loss. Since both exercise protocols have been demonstrated as useful to reduce body weight, the decision on the intensity of exercise prescription should be individualized and based on outcomes different from fat or weight loss. In this regard, there are pro and contra arguments for the prescription of high-intensity aerobic exercise in obese people. Among the pro arguments, is the demonstration that, in several studies, high-intensity training appears to induce superior improvements in aerobic fitness. Among the contra arguments to prescribe high-intensity exercise is the demonstration that prescribing a higher-intensity exercise decreases adherence and results in the completion of less exercise. Thus, a successful exercise program should be proposed at a moderate intensity and a low perceived effort because obese subjects who have low self-efficacy, poor mood status, and are not familiar with high-intensity workouts could easily drop out. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Combination of multibeam backscatter and bathymetry: A method to characterize the sea floor

    Science.gov (United States)

    Beyer, A.; Chakraborty, B.; Schenke, H. W.

    2003-04-01

    A high resolution multibeam survey was conducted by the RV "Polarstern" in order to identify and map locations of carbonate mounds in the Porcupine Seabight west of Ireland utilizing the multibeam echo sounder Hydrosweep DS-2. The scientific interest of that area rose due to an expected link between the carbonate mounds and subsurface hydrocarbon resources. In addition to the depths measurements the acoustic intensity of the received echo was recorded for individual measurements. After processing of the echo amplitudes by employing NRGCOR software the backscatter strength of the ensonified seafloor is used to identify areas of similar physical properties. Normalization was applied to the backscatter data to obtain acoustic response information which is independent from the incidence angle of the sonar beam. The mapped grey scale variation of the acoustic response is used to separate different types of seafloor. Four distinct types of seafloor have been depicted which are mounds, buried mounds, channel seafloor and inter channel areas. A semi-empirical method was applied to determine shape aspects of the angular backscatter strength. Three parameters, i.e. predicted 20° angular response, slope and coefficient of variation of the angular backscatter responses were computed to understand varying seafloor characteristics. The combination of backscatter and bathymetric data is another significant aspect of this contribution. Applying 3D visualisation techniques enables the user to link acoustic backscatter response to the seafloor morphology.

  20. Assessment of the CALIPSO Lidar 532 nm attenuated backscatter calibration using the NASA LaRC airborne High Spectral Resolution Lidar

    Directory of Open Access Journals (Sweden)

    R. R. Rogers

    2011-02-01

    Full Text Available The Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP instrument on the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO spacecraft has provided global, high-resolution vertical profiles of aerosols and clouds since it became operational on 13 June 2006. On 14 June 2006, the NASA Langley Research Center (LaRC High Spectral Resolution Lidar (HSRL was deployed aboard the NASA Langley B-200 aircraft for the first of a series of 86 underflights of the CALIPSO satellite to provide validation measurements for the CALIOP data products. To better assess the range of conditions under which CALIOP data products are produced, these validation flights were conducted under both daytime and nighttime lighting conditions, in multiple seasons, and over a large range of latitudes and aerosol and cloud conditions. This paper presents a quantitative assessment of the CALIOP 532 nm calibration (through the 532 nm total attenuated backscatter using internally calibrated airborne HSRL underflight data and is the most extensive study of CALIOP 532 nm calibration. Results show that HSRL and CALIOP 532 nm total attenuated backscatter agree on average within 2.7% ± 2.1% (CALIOP lower at night and within 2.9% ± 3.9% (CALIOP lower during the day, demonstrating the accuracy of the CALIOP 532 nm calibration algorithms. Additionally, comparisons with HSRL show consistency of the CALIOP calibration before and after the laser switch in 2009 as well as improvements in the daytime version 3.01 calibration scheme compared with the version 2 calibration scheme. Potential biases and uncertainties in the methodology relevant to validating satellite lidar measurements with an airborne lidar system are discussed and found to be less than 4.5% ± 3.2% for this validation effort with HSRL. Results from this study are also compared with prior assessments of the CALIOP 532 nm attenuated backscatter calibration.

  1. SALIVARY CORTISOL RESPONSES AND PERCEIVED EXERTION DURING HIGH INTENSITY AND LOW INTENSITY BOUTS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2004-03-01

    Full Text Available The purpose of this study was to measure the salivary cortisol response to different intensities of resistance exercise. In addition, we wanted to determine the reliability of the session rating of perceived exertion (RPE scale to monitor resistance exercise intensity. Subjects (8 men, 9 women completed 2 trials of acute resistance training bouts in a counterbalanced design. The high intensity resistance exercise protocol consisted of six, ten-repetition sets using 75% of one repetition maximum (RM on a Smith machine squat and bench press exercise (12 sets total. The low intensity resistance exercise protocol consisted of three, ten-repetition sets at 30% of 1RM of the same exercises as the high intensity protocol. Both exercise bouts were performed with 2 minutes of rest between each exercise and sessions were repeated to test reliability of the measures. The order of the exercise bouts was randomized with least 72 hours between each session. Saliva samples were obtained immediately before, immediately after and 30 mins following each resistance exercise bout. RPE measures were obtained using Borg's CR-10 scale following each set. Also, the session RPE for the entire exercise session was obtained 30 minutes following completion of the session. There was a significant 97% increase in the level of salivary cortisol immediately following the high intensity exercise session (P<0.05. There was also a significant difference in salivary cortisol of 145% between the low intensity and high intensity exercise session immediately post-exercise (P<0.05. The low intensity exercise did not result in any significant changes in cortisol levels. There was also a significant difference between the session RPE values for the different intensity levels (high intensity 7.1 vs. low intensity 1.9 (P<0.05. The intraclass correlation coefficient for the session RPE measure was 0.95. It was concluded that the session RPE method is a valid and reliable method of

  2. High Intensity Accelerator and Neutron Source in China

    Science.gov (United States)

    Guan, Xialing; Wei, J.; Loong, Chun

    2011-06-01

    High intensity Accelerator is being studied all over world for numerous applications, which includes the waste transmutation, spallation neutron source and material irradiation facilities. The R/D activities of the technology of High intensity accelerator are also developed in China for some year, and have some good facilities around China. This paper will reports the status of some high intensity accelerators and neutron source in China, which including ADS/RFQ; CARR; CSNS; PKUNIFTY & CPHS. This paper will emphatically report the Compact Pulsed Hadron Source (CPHS) led by the Department of Engineering Physics of Tsinghua University in Beijing, China.

  3. ELECTRON CLOUD EFFECTS IN HIGH INTENSITY PROTON ACCELERATORS.

    Energy Technology Data Exchange (ETDEWEB)

    WEI,J.; MACEK,R.J.

    2002-04-14

    One of the primary concerns in the design and operation of high-intensity proton synchrotrons and accumulators is the electron cloud and associated beam loss and instabilities. Electron-cloud effects are observed at high-intensity proton machines like the Los Alamos National Laboratory's PSR and CERN's SPS, and investigated experimentally and theoretically. In the design of next-generation high-intensity proton accelerators like the Spallation Neutron Source ring, emphasis is made in minimizing electron production and in enhancing Landau damping. This paper reviews the present understanding of the electron-cloud effects and presents mitigation measures.

  4. Oscillations in the spectrum of nonlinear Thomson-backscattered radiation

    Directory of Open Access Journals (Sweden)

    C. A. Brau

    2004-02-01

    Full Text Available When an electron beam collides with a high-intensity laser beam, the spectrum of the nonlinear Thomson scattering in the backward direction shows strong oscillations like those in the spectrum of an optical klystron. Laser gain on the backward Thomson scattering is estimated using the Madey theorem, and the results suggest that Thomson-backscatter free-electron lasers are possible at wavelengths extending to the far uv using a terawatt laser beam from a chirped-pulse amplifier and a high-brightness electron beam from a needle cathode.

  5. Repeated high-intensity exercise in professional rugby union.

    Science.gov (United States)

    Austin, Damien; Gabbett, Tim; Jenkins, David

    2011-07-01

    The aim of the present study was to describe the frequency, duration, and nature of repeated high-intensity exercise in Super 14 rugby union. Time-motion analysis was used during seven competition matches over the 2008 and 2009 Super 14 seasons; five players from each of four positional groups (front row forwards, back row forwards, inside backs, and outside backs) were assessed (20 players in total). A repeated high-intensity exercise bout was considered to involve three or more sprints, and/or tackles and/or scrum/ruck/maul activities within 21 s during the same passage of play. The range of repeated high-intensity exercise bouts for each group in a match was as follows: 11-18 for front row forwards, 11-21 for back row forwards, 13-18 for inside backs, and 2-11 for outside backs. The durations of the most intense repeated high-intensity exercise bouts for each position ranged from 53 s to 165 s and the minimum recovery periods between repeated high-intensity exercise bouts ranged from 25 s for the back row forwards to 64 s for the front row forwards. The present results show that repeated high-intensity exercise bouts vary in duration and activities relative to position but all players in a game will average at least 10 changes in activity in the most demanding bouts and complete at least one tackle and two sprints. The most intense periods of activity are likely to last as long as 120 s and as little as 25 s recovery may separate consecutive repeated high-intensity exercise bouts. The present findings can be used by coaches to prepare their players for the most demanding passages of play likely to be experienced in elite rugby union.

  6. High-intensity interval training evokes larger serum BDNF levels compared with intense continuous exercise.

    Science.gov (United States)

    Saucedo Marquez, Cinthia Maria; Vanaudenaerde, Bart; Troosters, Thierry; Wenderoth, Nicole

    2015-12-15

    Exercise can have a positive effect on the brain by activating brain-derived neurotrophic factor (BDNF)-related processes. In healthy humans there appears to be a linear relationship between exercise intensity and the positive short-term effect of acute exercise on BDNF levels (i.e., the highest BDNF levels are reported after high-intensity exercise protocols). Here we performed two experiments to test the effectiveness of two high-intensity exercise protocols, both known to improve cardiovascular health, to determine whether they have a similar efficacy in affecting BDNF levels. Participants performed a continuous exercise (CON) protocol at 70% of maximal work rate and a high-intensity interval-training (HIT) protocol at 90% of maximal work rate for periods of 1 min alternating with 1 min of rest (both protocols lasted 20 min). We observed similar BDNF kinetics in both protocols, with maximal BDNF concentrations being reached toward the end of training (experiment 1). We then showed that both exercise protocols significantly increase BDNF levels compared with a rest condition (CON P = 0.04; HIT P exercise are slightly more effective than continuous high-intensity exercise for elevating serum BDNF. Additionally, 73% of the participants preferred the HIT protocol (P = 0.02). Therefore, we suggest that the HIT protocol might represent an effective and preferred intervention for elevating BDNF levels and potentially promoting brain health.

  7. Analytical calculations and Monte-Carlo simulations of a high-resolution backscattering spectrometer for the long wavelength target station at the Spallation neutron source

    Science.gov (United States)

    Bordallo, H. N.; Herwig, K. W.; Zsigmond, G.

    2002-09-01

    Using the Monte-Carlo simulation programs McStas and VITESS, we present the design principles of the proposed high-resolution inverse geometry spectrometer on the Spallation neutron source (SNS)—long wavelength target station (LWTS). LWTS will enable the combination of large energy and momentum transfer ranges with energy resolution. Indeed the resolution of this spectrometer lie between that routinely achieved by spin echo techniques and the design goal of the high-power target station (HPTS) backscattering spectrometer. This niche of energy resolution is interesting for the study of slow motions of large objects and we are led to the domain of large molecules—polymers and biological molecules.

  8. High Intensity Tactical Power Sources for the 1990 Army.

    Science.gov (United States)

    conceptual or physical study which may become feasible as high intensity power sources . These considerations include present state of the art of...requirements, energy and power output capabilities, and fixed costs. From these tables, it may be seen that a variety of electrical power sources would be...required to satisfy diverse requirements, but an attempt is made to categorize possible high intensity power sources into their areas of optimum

  9. Multi-Frequency Measured and Modeled Microwave Backscatter from a Highly Saline Snow Cover on Smooth First-Year Sea Ice

    Science.gov (United States)

    Nandan, V.; Geldsetzer, T.; Islam, T.; Yackel, J.; Gill, J. P. S.; Gunn, G. E.; Duguay, C. R.

    2015-12-01

    Monitoring Arctic sea ice and its snow cover variability is of prime importance in Cryosphere research. Snow cover plays major roles in the energy balance of Arctic sea ice and also required to understand the present condition and future behavior of first-year ice (FYI). Microwave remote sensing provides the most effective means to acquire near-real time thermodynamic information about snow cover on smooth FYI. Microwave interaction with snow-covered sea ice is a function of both snow and ice electro-thermo-physical properties such as shape, size and orientation of scatterers, surface roughness, complex dielectric constant as a function primarily of brine volume, and brine volume as a function of temperature, salinity and density; as well as microwave parameters such as incidence angle, polarization and wavelength. Fluctuations in snow cover thermodynamics affect microwave propagation, attenuation, and scattering through the influence that brine volume exerts on interfacial and volume characteristics of snow and ice layers. Previous studies exhibit reduced penetration depth and inaccurate snow thickness estimates, using a single-frequency approach (C-band), from highly saline snow covers. We present a case study based on an observational (Ku-, X- and C-band surface-based fully-polarimetric microwave scatterometer system) and theoretical multi-frequency approach (using first-order microwave scattering and penetration depth models), to understand the sensitivity of varying snow thermodynamics on microwave scattering and penetration. The study site is a 14cm highly saline snow cover over smooth FYI, near Resolute Bay, Nunavut, Canada (Figure 1), with in-situ snow property measurements acquired from 18th to 20th May 2012, when snow layer temperatures were found to be fluctuating (Figure 2). Preliminary results show variations in observed Ku-, X- and C-band VV backscatter (Figure 3) and penetration (Figure 5) for warm (18th and 20th May) and cold (19th May) snow cases

  10. Effect of high intensity ultrasound on the allergenicity of shrimp

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The tropomyosin fraction of shrimp proteins is potentially responsible for allergic reaction in individuals with genetic predisposition to allergy. However, there are no efficient and safe methods to reduce its allergenicity. High intensity ultrasound is known to change the structure of proteins. This study is aimed at assessing high intensity ultrasound's effect on the allergenicity of shrimp allergen. Shrimp and purified shrimp allergen were treated with high intensity ultrasound for 30~180 min. Extracts of treated samples were analyzed by enzyme-linked immunosorbent assay (ELISA) with pool serum of shrimp allergy patients and polyclonal anti-allergen antibodies and by immunoblotting after polyacrylamide gel electrophoresis. Shrimp treated with high intensity ultrasound showed a decrease in allergenicity measured with ELISA. A linear relationship between the immune response induced by treated shrimp allergen and the applied treatment time was observed. The decrease in allergenicity was confirmed by immunoblot assays with shrimp allergic patients serum. Allergenicity of shrimp allergen extracted from treated shrimp was higher than that of purified shrimp allergen with the same treatment time. Gel-filtration HPLC was applied for analysis of shrimp allergen after treatment with high intensity ultrasound. Some fractions were appeared with increasing treatment time. The results suggested that high intensity ultrasound could be used to reduce the allergenicity of shrimp.

  11. Cavitation inception by the backscattering of pressure waves from a bubble interface

    Energy Technology Data Exchange (ETDEWEB)

    Takahira, Hiroyuki, E-mail: takahira@me.osakafu-u.ac.jp; Ogasawara, Toshiyuki, E-mail: oga@me.osakafu-u.ac.jp; Mori, Naoto, E-mail: su101064@edu.osakafu-u.ac.jp; Tanaka, Moe [Osaka Prefecture University, 1-1 Gakuen-cho, Naka-ku, Sakai-shi, Osaka 599-8531 (Japan)

    2015-10-28

    The secondary cavitation that occurs by the backscattering of focused ultrasound from a primary cavitation bubble caused by the negative pressure part of the ultrasound (Maxwell, et al., 2011) might be useful for the energy exchange due to bubble oscillations in High Intensity Focused Ultrasound (HIFU). The present study is concerned with the cavitation inception by the backscattering of ultrasound from a bubble. In the present experiment, a laser-induced bubble which is generated by a pulsed focused laser beam with high intensity is utilized as a primary cavitation bubble. After generating the bubble, focused ultrasound is emitted to the bubble. The acoustic field and the bubble motion are observed with a high-speed video camera. It is confirmed that the secondary cavitation bubble clouds are generated by the backscattering from the laser-induced bubble. The growth of cavitation bubble clouds is analyzed with the image processing method. The experimental results show that the height and width of the bubble clouds grow in stepwise during their evolution. The direct numerical simulations are also conducted for the backscattering of incident pressure waves from a bubble in order to evaluate a pressure field near the bubble. It is shown that the ratio of a bubble collapse time t{sub 0} to a characteristic time of wave propagation t{sub S}, η = t{sub 0}/t{sub s}, is an important determinant for generating negative pressure region by backscattering. The minimum pressure location by the backscattering in simulations is in good agreement with the experiment.

  12. Reducing parametric backscattering by polarization rotation

    Science.gov (United States)

    Barth, Ido; Fisch, Nathaniel J.

    2016-10-01

    When a laser passes through underdense plasmas, Raman and Brillouin Backscattering can reflect a substantial portion of the incident laser energy. This is a major loss mechanism, for example, in employing lasers in inertial confinement fusion. However, by slow rotation of the incident linear polarization, the overall reflectivity can be reduced significantly. Particle in cell simulations show that, for parameters similar to those of indirect drive fusion experiments, polarization rotation reduces the reflectivity by a factor of 5. A general, fluid-model based analytical estimation for the reflectivity reduction agrees with simulations. However, in identifying the source of the backscatter reduction, it is difficult to disentangle the rotating polarization from the frequency separation based approach used to engineer the beam's polarization. Although the backscatter reduction arises similarly to other approaches that employ frequency separation, in the case here, the intensity remains constant in time.

  13. A real-time measure of cavitation induced tissue disruption by ultrasound imaging backscatter reduction.

    Science.gov (United States)

    Hall, Timothy L; Fowlkes, J Brian; Cain, Charles A

    2007-03-01

    A feedback method for obtaining real-time information on the mechanical disruption of tissue through ultrasound cavitation is presented. This method is based on a substantial reduction in ultrasound imaging backscatter from the target volume as the tissue structure is broken down. Ex-vivo samples of porcine liver were exposed to successive high-intensity ultrasound pulses at a low duty cycle to induce mechanical disruption of tissue parenchyma through cavitation (referred to as histotripsy). At the conclusion of treatment, B-scan imaging backscatter was observed to have decreased by 22.4 +/- 2.3 dB in the target location. Treated samples of tissue were found to contain disrupted tissue corresponding to the imaged hypoechoic volume with no remaining discernable structure and a sharp boundary. The observed, substantial backscatter reduction may be an effective feedback mechanism for assessing treatment efficacy in ultrasound surgery using pulsed ultrasound to create cavitation.

  14. Sputtering of SiN films by 540 keV C{sub 60}{sup 2+} ions observed using high-resolution Rutherford backscattering spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, K.; Morita, Y.; Kitayama, T.; Suzuki, M. [Department of Micro Engineering, Kyoto University, Kyoto 615-8540 (Japan); Narumi, K.; Saitoh, Y. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki-machi, Takasaki, Gumma 370-1292 (Japan); Tsujimoto, M.; Isoda, S. [Institute for Integrated Cell-Material Sciences, Kyoto University, Kyoto 606-8501 (Japan); Fujii, Y. [Center for Supports to Research and Education Activities, Kobe University, Kobe 657-8501 (Japan); Kimura, K., E-mail: kimura@kues.kyoto-u.ac.jp [Department of Micro Engineering, Kyoto University, Kyoto 615-8540 (Japan)

    2014-08-01

    Amorphous silicon nitride films deposited on Si(0 0 1) were irradiated with 540 keV C{sub 60} ions to fluences ranging from 2.5 × 10{sup 11} to 1 × 10{sup 14} ions/cm{sup 2}. The composition depth profiles of the irradiated samples were measured using high-resolution Rutherford backscattering spectroscopy. Both silicon and nitrogen in the film decrease rapidly with fluence. From the observed result the sputtering yields are obtained as 3900 ± 500 N atoms/ion and 1500 ± 1000 Si atoms/ion. Such large sputtering yield cannot be explained by either the elastic sputtering or the electronic sputtering, indicating that the synergy effect between the elastic sputtering and the electronic sputtering plays an important role.

  15. Strategy of high efficiency and refined high-intensity focused ultrasound and ultrasound monitoring imaging of thermal lesion and cavitation

    Science.gov (United States)

    Wan, Mingxi; Zhang, Siyuan; Lu, Mingzhu; Hu, Hong; Jing, Bowen; Liu, Runna; Zhong, Hui

    2017-03-01

    We proposed that high efficiency high-intensity focused ultrasound (HIFU) could be achieved by using a splitting transducer with various frequencies and focusing patterns, and explored the feasibility of using ultrafast active cavitation imaging (UACI), pulse inversion (PI) sub-harmonic cavitation imaging and bubble wavelet transform imaging for monitoring of cavitation during HIFU, as well as the ultrasonic B-mode images, differential integrated backscatter (IBS) images, Nakagami images and elastography for monitoring HIFU-induced lesion. The use of HIFU splitting transducer had the potential to increase the size of the thermal lesion in a shorter duration and may improve the ablation efficiency of HIFU and would shorten the exposure duration significantly. The spatial-temporal evolution of residual cavitation bubbles at the tissue-water interface was obtained by UACI and the results showed that the UACI had a frame rate high enough to capture the transient behavior of the cavitation bubbles. The experiments demonstrated that comparing with normal sub-harmonic and PI harmonic images, PI sub-harmonic images had higher sensitivity and CTR, which was conducive to showing cavitation bubbles. The CTR would be further improved by combining PI ultrafast plane wave transmitting with cavitation bubble wavelet transform.

  16. Electromagnetic backscattering from one-dimensional drifting fractal sea surface II: Electromagnetic backscattering model

    Science.gov (United States)

    Tao, Xie; William, Perrie; Shang-Zhuo, Zhao; He, Fang; Wen-Jin, Yu; Yi-Jun, He

    2016-07-01

    Sea surface current has a significant influence on electromagnetic (EM) backscattering signals and may constitute a dominant synthetic aperture radar (SAR) imaging mechanism. An effective EM backscattering model for a one-dimensional drifting fractal sea surface is presented in this paper. This model is used to simulate EM backscattering signals from the drifting sea surface. Numerical results show that ocean currents have a significant influence on EM backscattering signals from the sea surface. The normalized radar cross section (NRCS) discrepancies between the model for a coupled wave-current fractal sea surface and the model for an uncoupled fractal sea surface increase with the increase of incidence angle, as well as with increasing ocean currents. Ocean currents that are parallel to the direction of the wave can weaken the EM backscattering signal intensity, while the EM backscattering signal is intensified by ocean currents propagating oppositely to the wave direction. The model presented in this paper can be used to study the SAR imaging mechanism for a drifting sea surface. Project supported by the National Natural Science Foundation of China (Grant No. 41276187), the Global Change Research Program of China (Grant No. 2015CB953901), the Priority Academic Program Development of Jiangsu Higher Education Institutions, China, the Program for the Innovation Research and Entrepreneurship Team in Jiangsu Province, China, the Canadian Program on Energy Research and Development, and the Canadian World Class Tanker Safety Service Program.

  17. Electromagnetic backscattering from one-dimensional drifting fractal sea surface II:Electromagnetic backscattering model

    Institute of Scientific and Technical Information of China (English)

    谢涛; William Perrie; 赵尚卓; 方贺; 于文金; 何宜军

    2016-01-01

    Sea surface current has a significant influence on electromagnetic (EM) backscattering signals and may constitute a dominant synthetic aperture radar (SAR) imaging mechanism. An effective EM backscattering model for a one-dimensional drifting fractal sea surface is presented in this paper. This model is used to simulate EM backscattering signals from the drifting sea surface. Numerical results show that ocean currents have a significant influence on EM backscattering signals from the sea surface. The normalized radar cross section (NRCS) discrepancies between the model for a coupled wave-current fractal sea surface and the model for an uncoupled fractal sea surface increase with the increase of incidence angle, as well as with increasing ocean currents. Ocean currents that are parallel to the direction of the wave can weaken the EM backscattering signal intensity, while the EM backscattering signal is intensified by ocean currents propagating oppositely to the wave direction. The model presented in this paper can be used to study the SAR imaging mechanism for a drifting sea surface.

  18. Review of High-intensity Interval Training in Cardiac Rehabilitation.

    Science.gov (United States)

    Ito, Shigenori; Mizoguchi, Tatsuya; Saeki, Tomoaki

    2016-01-01

    For the secondary prevention of cardiovascular disease, comprehensive cardiac rehabilitation is required. This involves optimal medical therapy, education on nutrition and exercise therapy, and smoking cessation. Of these, efficient exercise therapy is a key factor. A highly effective training protocol is therefore warranted, which requires a high rate of compliance. Although moderate-intensity continuous training has been the main training regimen recommended in cardiac rehabilitation guidelines, high-intensity interval training has been reported to be more effective in the clinical and experimental setting from the standpoint of peak oxygen uptake and central and peripheral adaptations. In this review, we illustrate the scientific evidence for high-intensity interval training. We then verify this evidence and discuss its significance and the remaining issues.

  19. Benefits of High-Intensity Intensive Care Unit Physician Staffing under the Affordable Care Act

    Directory of Open Access Journals (Sweden)

    Sachin Logani

    2011-01-01

    Full Text Available The Affordable Care Act signed into law by President Obama, with its value-based purchasing program, is designed to link payment to quality processes and outcomes. Treatment of critically ill patients represents nearly 1% of the gross domestic product and 25% of a typical hospital budget. Data suggest that high-intensity staffing patterns in the intensive care unit (ICU are associated with cost savings and improved outcomes. We evaluate the literature investigating the cost-effectiveness and clinical outcomes of high-intensity ICU physician staffing as recommended by The Leapfrog Group (a consortium of companies that purchase health care for their employees and identify ways to overcome barriers to nationwide implementation of these standards. Hospitals that have implemented the Leapfrog initiative have demonstrated reductions in mortality and length of stay and increased cost savings. High-intensity staffing models appear to be an immediate cost-effective way for hospitals to meet the challenges of health care reform.

  20. The generation of high-quality, intense ion beams by ultra-intense lasers

    CERN Document Server

    Roth, M; Audebert, Patrick; Blazevic, A; Brambrink, E; Cowan, T E; Fuchs, J; Gauthier, J C; Geissel, M; Hegelich, M; Karsch, S; Meyer-Ter-Vehn, J; Ruhl, H; Schlegel, T; Stephens, R B

    2002-01-01

    Intense beams of protons and heavy ions have been observed in ultra-intense laser-solid interaction experiments. Thereby, a considerable fraction of the laser energy is transferred to collimated beams of energetic ions (e.g. up to 50 MeV protons; 100 MeV fluorine), which makes these beams highly interesting for various applications. Experimental results indicate a very short-pulse duration and an excellent beam quality, leading to beam intensities in the TW range. To characterize the beam quality and its dependence on laser parameters and target conditions we performed experiments using the 100 TW laser system at Laboratoire pour l'Utilisation des Lasers Intenses at the Ecole Polytechnique, France, with focused intensities exceeding 10 sup 1 sup 9 W cm sup - sup 2. We found a strong dependence on the target rear surface conditions allowing to tailor the ion beam by an appropriate target design. We also succeeded in the generation of heavy ion beams by suppressing the proton amount at the target surface. We wi...

  1. High-intensity light-emitting diode vs fluorescent tubes for intensive phototherapy in neonates.

    Science.gov (United States)

    Sherbiny, Hanan S; Youssef, Doaa M; Sherbini, Ahmad S; El-Behedy, Rabab; Sherief, Laila M

    2016-05-01

    Special blue fluorescent tubes are recommended by the American Academy of Pediatrics (AAP) as the most effective light source for lowering serum bilirubin. A high-intensity light-emitting diode ('super LED') could render intensive phototherapy more effective than the above conventional methods. This study compared the efficacy and safety of a high-intensity light-emitting diode bed vs conventional intensive phototherapy with triple fluorescent tube units as a rescue treatment for severe unconjugated neonatal hyperbilirubinaemia. This was a randomised, prospective trial. Two hundred jaundiced neonates ≥ 35 weeks gestation who met the criteria for intensive phototherapy as per AAP guidelines were randomly assigned to be treated either with triple fluorescent tube units (group 1, n = 100) or a super LED bed (group 2, n = 100). The outcome was the avoidance of exchange transfusion by successful control of hyperbilirubinaemia. Statistically significant higher success rates of intensive phototherapy were achieved among neonates treated with super LED (group 2) than in those treated conventionally (group 1) (87% vs 64%, P = 0.003). Significantly higher 'bilirubin decline' rates were reported in both haemolytic and non-haemolytic subgroups treated with the super LED bed compared with a similar sub-population in the conventionally treated group. Comparable numbers of neonates in both groups developed rebound jaundice (8% vs 10% of groups 1 and 2, respectively). Side-effects were mild in both groups, but higher rates of hyperthermia (12% vs 0%, P = 0.03), dehydration (8% vs 2%, P = 0.26) and skin rash (39% vs 1%, P = 0.002) were reported in the fluorescent tubes-treated group compared with the LED group. Super LED is a safe rescue treatment for severe neonatal hyperbilirubinaemia, and its implementation may reduce the need for exchange transfusion.

  2. Simulation study of the high intensity S-Band photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiongwei; Nakajima, Kazuhisa [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-10-01

    In this paper, we report the results of simulation study of the high intensity S-Band photoinjector. The aim of the simulation study is to transport high bunch charge with low emittance evolution. The simulation result shows that 7nC bunch with rms emittance 22.3 {pi} mm mrad can be outputted at the exit of photoinjector. (author)

  3. Acute plasma volume change with high-intensity sprint exercise.

    Science.gov (United States)

    Bloomer, Richard J; Farney, Tyler M

    2013-10-01

    When exercise is of long duration or of moderate to high intensity, a decrease in plasma volume can be observed. This has been noted for both aerobic and resistance exercise, but few data are available with regard to high-intensity sprint exercise. We measured plasma volume before and after 3 different bouts of acute exercise, of varying intensity, and/or duration. On different days, men (n = 12; 21-35 years) performed aerobic cycle exercise (60 minutes at 70% heart rate reserve) and 2 different bouts of cycle sprints (five 60-second sprints at 100% maximum wattage obtained during graded exercise testing (GXT) and ten 15-second sprints at 200% maximum wattage obtained during GXT). Blood was collected before and 0, 30, and 60 minutes postexercise and analyzed for hematocrit and hemoglobin and plasma volume was calculated. Plasma volume decreased significantly for all exercise bouts (p sprint bouts (∼19%) compared with aerobic exercise bouts (∼11%). By 30 minutes postexercise, plasma volume approached pre-exercise values. We conclude that acute bouts of exercise, in particular high-intensity sprint exercise, significantly decrease plasma volume during the immediate postexercise period. It is unknown what, if any negative implications these transient changes may have on exercise performance. Strength and conditioning professionals may aim to rehydrate athletes appropriately after high-intensity exercise bouts.

  4. Generation of Intense High-Order Vortex Harmonics

    CERN Document Server

    Zhang, Xiaomei; Shi, Yin; Wang, Xiaofeng; Zhang, Lingang; Wang, Wenpeng; Xu, Jiancai; Yi, Longqiong; Xu, Zhizhan

    2014-01-01

    This paper presents the method for the first time to generate intense high-order optical vortices that carry orbital angular momentum in the extreme ultraviolet region. In three-dimensional particle-in-cell simulation, both the reflected and transmitted light beams include high-order harmonics of the Laguerre-Gaussian (LG) mode when a linearly polarized LG laser pulse impinges on a solid foil. The mode of the generated LG harmonic scales with its order, in good agreement with our theoretical analysis. The intensity of the generated high-order vortex harmonics is close to the relativistic region, and the pulse duration can be in attosecond scale. The obtained intense vortex beam possesses the combined properties of fine transversal structure due to the high-order mode and the fine longitudinal structure due to the short wavelength of the high-order harmonics. Thus, the obtained intense vortex beam may have extraordinarily promising applications for high-capacity quantum information and for high-resolution dete...

  5. CHANGES OF BACKSCATTERING PARAMETERS DURING CHILLING INJURY IN BANANAS

    Directory of Open Access Journals (Sweden)

    NORHASHILA HASHIM

    2014-06-01

    Full Text Available The change in backscattering parameters during the appearance of chilling injury in bananas was investigated. Bananas were stored at a chilling temperature for two days and the degrees of the chilling injuries that appeared were measured before, during and after storage using backscattering imaging and visual assessment. Laser lights at 660 nm and 785 nm wavelengths were shot consecutively onto the samples in a dark room and a camera was used to capture the backscattered lights that appeared on the samples. The captured images were analysed and the changes of intensity against pixel count were plotted into graphs. The plotted graph provides useful information of backscattering parameters such as inflection point (IP, slope after inflection point (SA, and full width at half maximum (FWHM and saturation radius (RSAT. Results of statistical analysis indicated that there were significant changes of these backscattering parameters as chilling injury developed.

  6. High Intensity Particle Physics at PW-class laser facilities

    Science.gov (United States)

    Bulanov, Stepan; Schroeder, Carl; Esarey, Eric; Esirkepov, Timur; Kando, Masaki; Rosanov, Nikolay; Korn, Georg; Bulanov, Sergey V.; Leemans, Wim P.

    2015-11-01

    The processes typical for high intensity particle physics, i.e., the interactions of charged particles with strong electromagnetic fields, have attracted considerable interest recently. Some of these processes, previously believed to be of theoretical interest only, are now becoming experimentally accessible. High intensity electromagnetic (EM) fields significantly modify the interactions of particles and EM fields, giving rise to the phenomena that are not encountered either in classical or perturbative quantum theory of these interactions. One of such phenomena is the radiation reaction, which radically influences the electron motion in an electromagnetic standing wave formed by two super-intense counter-propagating laser pulses. Depending on the laser intensity and wavelength, either classical or quantum mode of radiation reaction prevail, or both are strong. When radiation reaction dominates, electron motion evolves to limit cycles and strange attractors. This creates a new framework for high energy physics experiments on an interaction of energetic charged particle beams and colliding super-intense laser pulses. Work supported by U.S. DOE under Contract No. DE-AC02-05CH11231.

  7. Light-intensity and high-intensity interval training improve cardiometabolic health in rats.

    Science.gov (United States)

    Batacan, Romeo B; Duncan, Mitch J; Dalbo, Vincent J; Connolly, Kylie J; Fenning, Andrew S

    2016-09-01

    Physical activity has the potential to reduce cardiometabolic risk factors but evaluation of different intensities of physical activity and the mechanisms behind their health effects still need to be fully established. This study examined the effects of sedentary behaviour, light-intensity training, and high-intensity interval training on biometric indices, glucose and lipid metabolism, inflammatory and oxidative stress markers, and vascular and cardiac function in adult rats. Rats (12 weeks old) were randomly assigned to 1 of 4 groups: control (CTL; no exercise), sedentary (SED; no exercise and housed in small cages to reduce activity), light-intensity trained (LIT; four 30-min exercise bouts/day at 8 m/min separated by 2-h rest period, 5 days/week), and high-intensity interval trained (HIIT, four 2.5-min work bouts/day at 50 m/min separated by 3-min rest periods, 5 days/week). After 12 weeks of intervention, SED had greater visceral fat accumulation (p < 0.01) and slower cardiac conduction (p = 0.04) compared with the CTL group. LIT and HIIT demonstrated beneficial changes in body weight, visceral and epididymal fat weight, glucose regulation, low-density lipoprotein cholesterol, total cholesterol, and mesenteric vessel contractile response compared with the CTL group (p < 0.05). LIT had significant improvements in insulin sensitivity and cardiac conduction compared with the CTL and SED groups whilst HIIT had significant improvements in systolic blood pressure and endothelium-independent vasodilation to aorta and mesenteric artery compared with the CTL group (p < 0.05). LIT and HIIT induce health benefits by improving traditional cardiometabolic risk factors. LIT improves cardiac health while HIIT promotes improvements in vascular health.

  8. Thomson scattering in high-intensity chirped laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Holkundkar, Amol R., E-mail: amol.holkundkar@pilani.bits-pilani.ac.in [Department of Physics, Birla Institute of Technology and Science, Pilani, Rajasthan 333031 (India); Harvey, Chris, E-mail: christopher.harvey@chalmers.se; Marklund, Mattias, E-mail: mattias.marklund@chalmers.se [Department of Applied Physics, Chalmers University of Technology, SE-41296 Gothenburg (Sweden)

    2015-10-15

    We consider the Thomson scattering of an electron in an ultra-intense laser pulse. It is well known that at high laser intensities, the frequency and brilliance of the emitted radiation will be greatly reduced due to the electron losing energy before it reaches the peak field. In this work, we investigate the use of a small frequency chirp in the laser pulse in order to mitigate this effect of radiation reaction. It is found that the introduction of a negative chirp means the electron enters a high frequency region of the field while it still has a large proportion of its original energy. This results in a significant enhancement of the frequency and intensity of the emitted radiation as compared to the case without chirping.

  9. Plasma-based polarization modulator for high-intensity lasers

    Science.gov (United States)

    Chen, Zi-Yu; Pukhov, Alexander

    2016-12-01

    Manipulation of laser pulses at high intensities is an important yet challenging issue. New types of plasma-based optical devices are promising alternatives to achieve this goal. Here we propose to modulate the polarization state of intense lasers based on oblique reflection from solid-plasma surfaces. A new analytical description is presented considering the plasma as an uniaxial medium that causes birefringence effect. Particle-in-cell simulation results numerically demonstrate that such a scheme can provide a tunable polarization control of the laser pulses even in the relativistic regime. The results are thus relevant for the design of compact, easy to use, and versatile polarization modulators for high-intensity laser pulses.

  10. Self-trapping of intensities changing under SHG and SWG for high intensive femtosecond laser pulse

    Science.gov (United States)

    Trofimov, Vyacheslav A.; Kharitonov, Dmitry M.; Fedotov, Mikhail V.

    2017-05-01

    SHG and SFG (SWG) and THG are used widely in many practical applications such as a substance diagnostics, and imaging of various physical, chemical and biological processes as well as for laser radiation frequency conversion. One of very interesting phenomena under the frequency conversion takes place if a basic wave incident intensity is enough high: a synchronic mode of the laser pulse intensities changing along a propagation coordinate appears under certain conditions. First of all, we investigate this phenomenon using the frame-work of long pulse duration approximation and plane wave approximation without applying the basic wave energy non-depletion approximation. Applying an original approach we derive the solution of Schr¨odinger equations describing the THG via a SHG process and summary frequency wave generation (SFG) process for femtosecond pulses. Among many modes of the frequency conversion process under consideration we found out analytically the mode corresponding to synchronous intensities changing for the interacting waves. We derive conditions of such mode realization in dependence of the problem parameters. After that we verify our analytical consideration using a computer simulation of the problem on the base of the corresponding Schr¨odinger equations. Computer simulation shown also a new phenomenon at three-wave interaction: interacting wave intensities changing with two (or more) oscillation periods.

  11. THERMAL NEUTRON BACKSCATTER IMAGING.

    Energy Technology Data Exchange (ETDEWEB)

    VANIER,P.; FORMAN,L.; HUNTER,S.; HARRIS,E.; SMITH,G.

    2004-10-16

    Objects of various shapes, with some appreciable hydrogen content, were exposed to fast neutrons from a pulsed D-T generator, resulting in a partially-moderated spectrum of backscattered neutrons. The thermal component of the backscatter was used to form images of the objects by means of a coded aperture thermal neutron imaging system. Timing signals from the neutron generator were used to gate the detection system so as to record only events consistent with thermal neutrons traveling the distance between the target and the detector. It was shown that this time-of-flight method provided a significant improvement in image contrast compared to counting all events detected by the position-sensitive {sup 3}He proportional chamber used in the imager. The technique may have application in the detection and shape-determination of land mines, particularly non-metallic types.

  12. Some Intensive and Extensive Quantities in High-Energy Collisions

    CERN Document Server

    Tawfik, A

    2013-01-01

    We review the evolution of some statistical and thermodynamical quantities measured in difference sizes of high-energy collisions at different energies. We differentiate between intensive and extensive quantities and discuss the importance of their distinguishability in characterizing possible critical phenomena of nuclear collisions at various energies with different initial conditions.

  13. High-Intensity Interval Training for Improving Postprandial Hyperglycemia

    Science.gov (United States)

    Little, Jonathan P.; Francois, Monique E.

    2014-01-01

    High-intensity interval training (HIIT) has garnered attention in recent years as a time-efficient exercise option for improving cardiovascular and metabolic health. New research demonstrates that HIIT may be particularly effective for improving postprandial hyperglycemia in individuals with, or at risk for, type 2 diabetes (T2D). These findings…

  14. Nonlinear Behavior in High-Intensity Discharge Lamps

    CERN Document Server

    Baumann, Bernd; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2015-01-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behaves very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  15. Nonlinear behavior in high-intensity discharge lamps

    Science.gov (United States)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2016-06-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behave very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  16. Parallel Beam Dynamics Code Development for High Intensity Cyclotron

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>1 Parallel PIC algorithm Self field solver is the key part of a high intensity beam dynamic PIC code which usually adopts the P-M (Particle-Mesh) method to solve the space charge. The P-M method is composed of four major

  17. Annotated bibliography on high-intensity linear accelerators. [240 citations

    Energy Technology Data Exchange (ETDEWEB)

    Jameson, R.A.; Roybal, E.U.

    1978-01-01

    A technical bibliography covering subjects important to the design of high-intensity beam transport systems and linear accelerators is presented. Space charge and emittance growth are stressed. Subject and author concordances provide cross-reference to detailed citations, which include an abstract and notes on the material. The bibliography resides in a computer database that can be searched for key words and phrases.

  18. Intense neutron source: high-voltage power supply specifications

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply.

  19. Reuse Recycler: High Intensity Proton Stacking at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, P. [Fermilab

    2016-07-17

    After a successful career as an antiproton storage and cooling ring, Recycler has been converted to a high intensity proton stacker for the Main Injector. We discuss the commissioning and operation of the Recycler in this new role, and the progress towards the 700 kW design goal.

  20. Strong Localization in Disordered Media: Analysis of the Backscattering Cone

    KAUST Repository

    Delgado, Edgar

    2012-06-01

    A very interesting effect in light propagation through a disordered system is Anderson localization of light, this phenomenon emerges as the result of multiple scattering of waves by electric inhomogeneities like spatial variations of index of refraction; as the amount of scattering is increased, light propagation is converted from quasi-diffusive to exponentially localized, with photons confined in a limited spatial region characterized by a fundamental quantity known as localization length. Light localization is strongly related to another interference phenomenon emerged from the multiple scattering effect: the coherent backscattering effect. In multiple scattering of waves, in fact, coherence is preserved in the backscattering direction and produces a reinforcement of the field flux originating an observable peak in the backscattered intensity, known as backscattering cone. The study of this peak provide quantitative information about the transport properties of light in the material. In this thesis we report a complete FDTD ab-initio study of light localization and coherent backscattering. In particular, we consider a supercontinuum pulse impinging on a sample composed of randomly positioned scatterers. We study coherent backscattering by averaging over several realizations of the sample properties. We study then the coherent backscattering cone properties as the relative permittivity of the sample is changed, relating the latter with the light localization inside the sample. We demonstrate important relationships between the width of the backscattering cone and the localization length, which shows a linear proportionality in the strong localization regime.

  1. Production of High-Intensity, Highly Charged Ions

    CERN Document Server

    Gammino, S

    2013-01-01

    In the past three decades, the development of nuclear physics facilities for fundamental and applied science purposes has required an increasing current of multicharged ion beams. Multiple ionization implies the formation of dense and energetic plasmas, which, in turn, requires specific plasma trapping configurations. Two types of ion source have been able to produce very high charge states in a reliable and reproducible way: electron beam ion sources (EBIS) and electron cyclotron resonance ion sources (ECRIS). Multiple ionization is also obtained in laser-generated plasmas (laser ion sources (LIS)), where the high-energy electrons and the extremely high electron density allow step-by-step ionization, but the reproducibility is poor. This chapter discusses the atomic physics background at the basis of the production of highly charged ions and describes the scientific and technological features of the most advanced ion sources. Particular attention is paid to ECRIS and the latest developments, since they now r...

  2. Towards optical intensity interferometry for high angular resolution stellar astrophysics

    CERN Document Server

    Nunez, Paul D

    2012-01-01

    Most neighboring stars are still detected as point sources and are beyond the angular resolution reach of current observatories. Methods to improve our understanding of stars at high angular resolution are investigated. Air Cherenkov telescopes (ACTs), primarily used for Gamma-ray astronomy, enable us to increase our understanding of the circumstellar environment of a particular system. When used as optical intensity interferometers, future ACT arrays will allow us to detect stars as extended objects and image their surfaces at high angular resolution. Optical stellar intensity interferometry (SII) with ACT arrays, composed of nearly 100 telescopes, will provide means to measure fundamental stellar parameters and also open the possibility of model-independent imaging. A data analysis algorithm is developed and permits the reconstruction of high angular resolution images from simulated SII data. The capabilities and limitations of future ACT arrays used for high angular resolution imaging are investigated via ...

  3. Coherent keV backscattering from plasma-wave boosted relativistic electron mirrors

    CERN Document Server

    Li, F Y; Chen, M; Wu, H C; Liu, Y; Meyer-ter-Vehn, J; Mori, W B; Zhang, J

    2014-01-01

    A new parameter regime of laser wakefield acceleration driven by sub-petawatt femotsecond lasers is proposed, which enables the generation of relativistic electron mirrors further accelerated by the plasma wave. Integrated particle-in-cell simulation including the mirror formation and Thomson scattering demonstrates that efficient coherent backscattering up to keV photon energy can be obtained with moderate driver laser intensities and high density gas targets.

  4. Production of High-Intensity, Highly Charged Ions

    OpenAIRE

    S. GamminoINFN, LNS, Catania

    2014-01-01

    In the past three decades, the development of nuclear physics facilities for fundamental and applied science purposes has required an increasing current of multicharged ion beams. Multiple ionization implies the formation of dense and energetic plasmas, which, in turn, requires specific plasma trapping configurations. Two types of ion source have been able to produce very high charge states in a reliable and reproducible way: electron beam ion sources (EBIS) and electron cyc...

  5. CW high intensity non-scaling FFAG proton drivers

    CERN Document Server

    Johnstone, C; Makino, K; Snopok, P

    2012-01-01

    Accelerators are playing increasingly important roles in basic science, technology, and medicine including nuclear power, industrial irradiation, material science, and neutrino production. Proton and light-ion accelerators in particular have many research, energy and medical applications, providing one of the most effective treatments for many types of cancer. Ultra high-intensity and high-energy (GeV) proton drivers are a critical technology for accelerator-driven sub-critical reactors (ADS) and many HEP programs (Muon Collider). These high-intensity GeV-range proton drivers are particularly challenging, encountering duty cycle and space-charge limits in the synchrotron and machine size concerns in the weaker-focusing cyclotrons; a 10-20 MW proton driver is not presently considered technically achievable with conventional re-circulating accelerators. One, as-yet, unexplored re-circulating accelerator, the Fixed-field Alternating Gradient, or FFAG, is an attractive alternative to the cyclotron. Its strong foc...

  6. Excitation thresholds of field-aligned irregularities and associated ionospheric hysteresis at very high latitudes observed using SPEAR-induced HF radar backscatter

    Directory of Open Access Journals (Sweden)

    D. M. Wright

    2009-07-01

    Full Text Available On 10 October 2006 the SPEAR high power radar facility was operated in a power-stepping mode where both CUTLASS radars were detecting backscatter from the SPEAR-induced field-aligned irregularities (FAIs. The effective radiated power of SPEAR was varied from 1–10 MW. The aim of the experiment was to investigate the power thresholds for excitation (Pt and collapse (Pc of artificially-induced FAIs in the ionosphere over Svalbard. It was demonstrated that FAI could be excited by a SPEAR ERP of only 1 MW, representing only 1/30th of SPEAR's total capability, and that once created the irregularities could be maintained for even lower powers. The experiment also demonstrated that the very high latitude ionosphere exhibits hysteresis, where the down-going part of the power cycle provided a higher density of irregularities than for the equivalent part of the up-going cycle. Although this second result is similar to that observed previously by CUTLASS in conjunction with the Tromsø heater, the same is not true for the equivalent incoherent scatter measurements. The EISCAT Svalbard Radar (ESR failed to detect any hysteresis in the plasma parameters over Svalbard in stark contract with the measurements made using the Tromsø UHF.

  7. Ultra High Performance, Highly Reliable, Numeric Intensive Processors and Systems

    Science.gov (United States)

    1989-10-01

    to design high-performance DSP/IP systems using either off-the-shelf components or application specific integrated circuitry [ ASIC ]. -9 - HSDAL . ARO...are the chirp-z transform ( CZT ) [13] and (Rader’s) Prime Factor Transform (PFT) [11]. The RNS/ CZT is being studied by a group a MITRE [14] and is given...PFT RNS/CRNS/QRNS implementation has dynamic range requirements on the order of NQ2 (vs NQ4 for the CZT and much higher for the FFT). Therefore, the

  8. A multivariate analytical method to characterize sediment attributes from high-frequency acoustic backscatter and ground-truthing data (Jade Bay, German North Sea coast)

    Science.gov (United States)

    Biondo, Manuela; Bartholomä, Alexander

    2017-04-01

    One of the burning issues on the topic of acoustic seabed classification is the lack of solid, repeatable, statistical procedures that can support the verification of acoustic variability in relation to seabed properties. Acoustic sediment classification schemes often lead to biased and subjective interpretation, as they ultimately aim at an oversimplified categorization of the seabed based on conventionally defined sediment types. However, grain size variability alone cannot be accounted for acoustic diversity, which will be ultimately affected by multiple physical processes, scale of heterogeneity, instrument settings, data quality, image processing and segmentation performances. Understanding and assessing the weight of all of these factors on backscatter is a difficult task, due to the spatially limited and fragmentary knowledge of the seabed from of direct observations (e.g. grab samples, cores, videos). In particular, large-scale mapping requires an enormous availability of ground-truthing data that is often obtained from heterogeneous and multidisciplinary sources, resulting into a further chance of misclassification. Independently from all of these limitations, acoustic segments still contain signals for seabed changes that, if appropriate procedures are established, can be translated into meaningful knowledge. In this study we design a simple, repeatable method, based on multivariate procedures, with the scope to classify a 100 km2, high-frequency (450 kHz) sidescan sonar mosaic acquired in the year 2012 in the shallow upper-mesotidal inlet of the Jade Bay (German North Sea coast). The tool used for the automated classification of the backscatter mosaic is the QTC SWATHVIEWTMsoftware. The ground-truthing database included grab sample data from multiple sources (2009-2011). The method was designed to extrapolate quantitative descriptors for acoustic backscatter and model their spatial changes in relation to grain size distribution and morphology. The

  9. Generation of Ultra-high Intensity Laser Pulses

    Energy Technology Data Exchange (ETDEWEB)

    N.J. Fisch; V.M. Malkin

    2003-06-10

    Mainly due to the method of chirped pulse amplification, laser intensities have grown remarkably during recent years. However, the attaining of very much higher powers is limited by the material properties of gratings. These limitations might be overcome through the use of plasma, which is an ideal medium for processing very high power and very high total energy. A plasma can be irradiated by a long pump laser pulse, carrying significant energy, which is then quickly depleted in the plasma by a short counterpropagating pulse. This counterpropagating wave effect has already been employed in Raman amplifiers using gases or plasmas at low laser power. Of particular interest here are the new effects which enter in high power regimes. These new effects can be employed so that one high-energy optical system can be used like a flashlamp in what amounts to pumping the plasma, and a second low-power optical system can be used to extract quickly the energy from the plasma and focus it precisely. The combined system can be very compact. Thus, focused intensities more than 10{sup 25} W/cm{sup 2} can be contemplated using existing optical elements. These intensities are several orders of magnitude higher than what is currently available through chirped pump amplifiers.

  10. A transparent vacuum window for high-intensity pulsed beams

    CERN Document Server

    Monteil, M; Veness, R

    2011-01-01

    The HiRadMat (High-Radiation to Materials) facility Ill will allow testing of accelerator components, in particular those of the Large Hadron Collider (LHC) at CERN, under the impact of high-intensity pulsed beams. To reach this intensity range, the beam will be focused on a focal point where the target to be tested is located. A 60 mm aperture vacuum window will separate the vacuum of the beam line which is kept under high vacuum 10(-8) mbar, from the test area which is at atmospheric pressure. This window has to resist collapse due to beam passage. The high-intensity of the beam means that typical materials used for standard vacuum windows (such as stainless steel, aluminium and titanium alloy) cannot endure the energy deposition induced by the beam passage. Therefore, a vacuum window has been designed to maintain the differential pressure whilst resisting collapse due to the beam impact on the window. In this paper, we will present calculations of the energy transfer from beam to window, the design of the ...

  11. Heat transparent high intensity high efficiency solar cell

    Science.gov (United States)

    Evans, J. C., Jr. (Inventor)

    1982-01-01

    An improved solar cell design is described. A surface of each solar cell has a plurality of grooves. Each groove has a vertical face and a slanted face that is covered by a reflecting metal. Light rays are reflected from the slanted face through the vertical face where they traverse a photovoltaic junction. As the light rays travel to the slanted face of an adjacent groove, they again traverse the junction. The underside of the reflecting coating directs the light rays toward the opposite surface of solar cell as they traverse the junction again. When the light rays travel through the solar cell and reach the saw toothed grooves on the under side, the process of reflection and repeatedly traversing the junction again takes place. The light rays ultimately emerge from the solar cell. These solar cells are particularly useful at very high levels of insolation because the infrared or heat radiation passes through the cells without being appreciably absorbed to heat the cell.

  12. High Intensity Beam Issues in the CERN Proton Synchrotron

    CERN Document Server

    Aumon, Sandra; Rivkin, Leonid

    This PhD work is about limitations of high intensity proton beams observed in the CERN Proton Synchrotron (PS) and, in particular, about issues at injection and transition energies. With its 53 years, the CERN PS would have to operate beyond the limit of its performance to match the future requirements. Beam instabilities driven by transverse impedance and aperture restrictions are important issues for the operation and for the High-Luminosity LHC upgrade which foresees an intensity increase delivered by the injectors. The main subject of the thesis concerns the study of a fast transverse instability occurring at transition energy. The proton beams crossing this energy range are particularly sensitive to wake forces because of the slow synchrotron motion. This instability can cause a strong vertical emittance blow-up and severe losses in less than a synchrotron period. Experimental observations show that the particles at the peak density of the beam longitudinal distribution oscillate in the vertical plane du...

  13. High-Intensity Focused Ultrasound Therapy: an Overview for Radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Sun; Rhim, Hyun Chul; Lim, Hyo Keun; Choi, Dong Il [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choi, Min Joo [College of Medicine, Cheju National University, Jeju (Korea, Republic of)

    2008-08-15

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments

  14. High-intensity focused ultrasound therapy: an overview for radiologists.

    Science.gov (United States)

    Kim, Young-sun; Rhim, Hyunchul; Choi, Min Joo; Lim, Hyo Keun; Choi, Dongil

    2008-01-01

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments.

  15. Fermilab main injector: High intensity operation and beam loss control

    Science.gov (United States)

    Brown, Bruce C.; Adamson, Philip; Capista, David; Chou, Weiren; Kourbanis, Ioanis; Morris, Denton K.; Seiya, Kiyomi; Wu, Guan Hong; Yang, Ming-Jen

    2013-07-01

    From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at 400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about 1.5 kW of beam loss. By minimizing and localizing loss, residual radiation levels fell while beam power was doubled. Lost beam was directed to either the collimation system or to the beam abort. Critical apertures were increased while improved instrumentation allowed optimal use of available apertures. We will summarize the improvements required to achieve high intensity, the impact of various loss control tools and the status and trends in residual radiation in the Main Injector.

  16. Low-intensity resistance training after high-intensity resistance training can prevent the increase of central arterial stiffness.

    Science.gov (United States)

    Okamoto, T; Masuhara, M; Ikuta, K

    2013-05-01

    Although high-intensity resistance training increases arterial stiffness, low-intensity resistance training reduces arterial stiffness. The present study investigates the effect of low-intensity resistance training before and after high-intensity resistance training on arterial stiffness. 30 young healthy subjects were randomly assigned to a group that performed low-intensity resistance training before high-intensity resistance training (BLRT, n=10), a group that performed low-intensity resistance training after high-intensity resistance training (ALRT, n=10) and a sedentary control group (n=10). The BLRT and ALRT groups performed resistance training at 80% and 50% of one repetition maximum twice each week for 10 wk. Arterial stiffness was measured using carotid-femoral and femoral-ankle pulse wave velocity (PWV). One-repetition maximum strength in the both ALRT and BLRT significantly increased after the intervention (Ptraining in the ALRT group did not change from before training. In contrast, carotid-femoral PWV after combined training in the BLRT group increased from before training (P training in the both BLRT and ALRT groups did not change from before training. These results suggest that although arterial stiffness is increased by low-intensity resistance training before high-intensity resistance training, performing low-intensity resistance training thereafter can prevent the increase of arterial stiffness. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Spallation neutron source and other high intensity froton sources

    Energy Technology Data Exchange (ETDEWEB)

    Weiren Chou

    2003-02-06

    This lecture is an introduction to the design of a spallation neutron source and other high intensity proton sources. It discusses two different approaches: linac-based and synchrotron-based. The requirements and design concepts of each approach are presented. The advantages and disadvantages are compared. A brief review of existing machines and those under construction and proposed is also given. An R&D program is included in an appendix.

  18. Entrepreneurship in high-tech and knowledge-intensive sectors

    DEFF Research Database (Denmark)

    Christensen, Patrizia V.; Madsen, Henning; Neergaard, Helle

    development of new enterprises in high-tech and knowledge-intensive sectors are analysed in relation to the educational and professional background of the entrepreneur/entrepreneurial team, as well as the personal and professional social networks of the entrepreneurs. The analysis is based on a theoretical...... framework combining theories of human and social capital. Secondary aspects addressed in the research project are questions of male vs. female entrepreneurship, internationalisation-globalisation, and business success/failure....

  19. Aerosol backscatter measurements at 10. 6 micrometers with airborne and ground-based CO sub 2 Doppler lidars over the Colorado high plains. 1. Lidar intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Bowdle, D.A. (Univ. of Alabama, Huntsville (USA)); Rothermel, J. (NASA Marshall Space Flight Center, Huntsville, AL (USA)); Vaughan, J.M.; Brown, D.W. (Royal Signals and Radar Establishment, Worcestershire (England)); Post, M.J. (National Oceanic and Atmospheric Administration, Boulder, CO (USA))

    1991-03-20

    An airborne continuous wave (CW) focused CO{sub 2} Doppler lidar and a ground-based pulsed CO{sub 2} Doppler lidar were used to obtain seven pairs of comparative measurements of tropospheric aerosol backscatter profiles at 10.6 {mu}m wavelength, near Denver, Colorado, during a 20-day period in July 1982. In regions of uniform backscatter the two lidars show good agreement, with differences usually less than {approximately}50% near 8-km altitude and less than a factor of 2 or 3 elsewhere but with the pulsed lidar often lower than the CW lidar. Near sharp backscatter gradients the two lidars show poorer agreement, with the pulsed lidar usually higher than the CW lidar. Most discrepancies arise from a combination of atmospheric factors and instrument factors, particularly small-scale areal and temporal backscatter heterogeneity above the planetary boundary layer, unusual large-scale vertical backscatter structure in the upper troposphere and lower stratosphere, and differences in the spatial resolution, detection threshold, and noise estimation for the two lidars.

  20. Compton spectra of atoms at high x-ray intensity

    Science.gov (United States)

    Son, Sang-Kil; Geffert, Otfried; Santra, Robin

    2017-03-01

    Compton scattering is the nonresonant inelastic scattering of an x-ray photon by an electron and has been used to probe the electron momentum distribution in gas-phase and condensed-matter samples. In the low x-ray intensity regime, Compton scattering from atoms dominantly comes from bound electrons in neutral atoms, neglecting contributions from bound electrons in ions and free (ionized) electrons. In contrast, in the high x-ray intensity regime, the sample experiences severe ionization via x-ray multiphoton multiple ionization dynamics. Thus, it becomes necessary to take into account all the contributions to the Compton scattering signal when atoms are exposed to high-intensity x-ray pulses provided by x-ray free-electron lasers (XFELs). In this paper, we investigate the Compton spectra of atoms at high x-ray intensity, using an extension of the integrated x-ray atomic physics toolkit, xatom. As the x-ray fluence increases, there is a significant contribution from ionized electrons to the Compton spectra, which gives rise to strong deviations from the Compton spectra of neutral atoms. The present study provides not only understanding of the fundamental XFEL-matter interaction but also crucial information for single-particle imaging experiments, where Compton scattering is no longer negligible. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Sang-Kil Son was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  1. Muscle fatigue during high-intensity exercise in children.

    Science.gov (United States)

    Ratel, Sébastien; Duché, Pascale; Williams, Craig A

    2006-01-01

    Children are able to resist fatigue better than adults during one or several repeated high-intensity exercise bouts. This finding has been reported by measuring mechanical force or power output profiles during sustained isometric maximal contractions or repeated bouts of high-intensity dynamic exercises. The ability of children to better maintain performance during repeated high-intensity exercise bouts could be related to their lower level of fatigue during exercise and/or faster recovery following exercise. This may be explained by muscle characteristics of children, which are quantitatively and qualitatively different to those of adults. Children have less muscle mass than adults and hence, generate lower absolute power during high-intensity exercise. Some researchers also showed that children were equipped better for oxidative than glycolytic pathways during exercise, which would lead to a lower accumulation of muscle by-products. Furthermore, some reports indicated that the lower ability of children to activate their type II muscle fibres would also explain their greater resistance to fatigue during sustained maximal contractions. The lower accumulation of muscle by-products observed in children may be suggestive of a reduced metabolic signal, which induces lower ratings of perceived exertion. Factors such as faster phosphocreatine resynthesis, greater oxidative capacity, better acid-base regulation, faster readjustment of initial cardiorespiratory parameters and higher removal of metabolic by-products in children could also explain their faster recovery following high-intensity exercise.From a clinical point of view, muscle fatigue profiles are different between healthy children and children with muscle and metabolic diseases. Studies of dystrophic muscles in children indicated contradictory findings of changes in contractile properties and the muscle fatigability. Some have found that the muscle of boys with Duchenne muscular dystrophy (DMD) fatigued less

  2. Intelligent Controller of Digital High Intensity Discharge Lamp

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    High-intensity discharge (HID) lamps include these types of electrical lamps: mercury vapor, metal halide (also HQI), high-pressure sodium, low-pressure sodium and less commonly, xenon short-arc lamps. The light-producing element of these lamp types is a well-stabilized arc discharge contained within a refractory envelope (arc tube) with wall loading in excess of 3 W/cm (19.4 W/in.). Compared to fluorescent and incandescent lamps, HID lamps produce a much larger quantity of light in a relatively small package. With tests made by the National Quality Supervision and

  3. The joint project for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK) agreed to promote the joint project integrating both the Neutron Science Project (NSP) of JAERI and the Japan Hadron Facility Project (JHF) of KEK for comprehensive studies on basic science and technology using high-intensity proton accelerator. This document describes the joint proposal prepared by the Joint Project Team of JAERI and KEK to construct accelerators and research facilities necessary both for the NSP and the JHF at the site of JAERI Tokai Establishment. (author)

  4. High intensity Discharge lighting; Alumbrado de alta intensidad de descarga

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza E, Ernesto J. [Manufacturera de Reactores, S. A., Mexico, D. F. (Mexico)

    1993-12-31

    This paper gets into contact with some fundamentals in the operation of high discharge intensity lamps. There are useful definitions, as well as the study of the operation of high pressure sodium lamps and of metallic additives operating at less than nominal power. [Espanol] Este trabajo pone al lector en contacto con algunos fundamentos de la operacion de las lamparas de alta intensidad de descarga (HID). Se encuentra con definiciones utiles, asi como el estudio de la operacion de las lamparas de sodio en alta presion y de aditivos metalicos operando a una potencia menor que la nominal.

  5. Removing Known SPS Intensity Limitations for High Luminosity LHC Goals

    CERN Document Server

    Shaposhnikova, Elena; Bohl, Thomas; Cruikshank, Paul; Goddard, Brennan; Kaltenbacher, Thomas; Lasheen, Alexandre; Perez Espinos, Jaime; Repond, Joël; Salvant, Benoit; Vollinger, Christine

    2016-01-01

    In preparation of the SPS as an LHC injector its impedance was significantly reduced in 1999 - 2000. A new SPS impedance reduction campaign is planned now for the High Luminosity (HL)-LHC project, which requires bunch intensities twice as high as the nominal one. One of the known intensity limitations is a longitudinal multi-bunch instability with a threshold 3 times below this operational intensity. The instability is presently cured using the 4th harmonic RF system and controlled emittance blow-up, but reaching the HL-LHC parameters cannot be assured without improving the machine impedance. Recently the impedance sources responsible for this instability were identified and implementation of their shielding and damping is foreseen during the next long shutdown (2019 - 2020) in synergy with two other important upgrades: amorphous carbon coating of (part of) the vacuum chamber against the e-cloud effect and rearrangement of the 200 MHz RF system. In this paper the strategy of impedance reduction is presented t...

  6. High-intensity positron microprobe at Jefferson Lab

    CERN Document Server

    Golge, Serkan; Wojtsekhowski, Bogdan

    2014-01-01

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity slow-positron production source with a projected intensity on the order of 10$^{10}$ e$^+$/s. Reaching this intensity in our design relies on the transport of positrons (T$_+$ below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. The performance of the integrated beamline has been verified through computational studies. The computational results include Monte Carlo calculations of the optimized electron/positron beam energies, converter target thickness, synchronized raster system, transport of the beam from the converter target to the moderator, extraction of the beam from the channel, and moderation efficiency calculations. For the extraction of positrons from the magnetic channel a magnetic field terminator plug prototype has been built and experimental data on the effective...

  7. FNAL Proton Source High Intensity Operations and Beam Loss Control

    CERN Document Server

    Garcia, F G

    2014-01-01

    The 40-year-old Fermilab Proton Source machines, constituted by the Pre-Injector, Linac and the synchrotron Booster, have been the workhorse of the Fermi National Accelerator Laboratory (Fermilab). During this time, the High Energy Physics Program has demanded an increase in proton throughput, especially during the past decade with the beginning of the neutrino program at Fermilab. In order to achieve a successful program, major upgrades and changes were made in Booster. Once again, the Proton Source has been charged to double their beam throughput, while maintain the present residual activation levels, to meet the laboratory Intensity Frontier program goals until new machines are built and operational to replace the Proton Source machines. This paper discusses the present performance of Booster and the plans involved in reaching even higher intensities.

  8. Raman forward scattering of high-intensity chirped laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, C.B.; Esarey, E.; Shadwick, B.A.; Leemans, W.P.

    2002-06-23

    Raman forward scattering of a high-intensity, short-duration, frequency-chirped laser pulse propagating in an underdense plasma is examined. The growth of the direct forward scattered light is calculated for a laser pulse with a linear frequency chirp in various spatio-temporal regimes. This includes a previously undescribed regime of strongly-coupled four-wave nonresonant interaction, which is important for relativistic laser intensities. In all regimes of forward scattering, it is shown that the growth rate increases (decreases) for positive (negative) frequency chirp. The effect of chirp on the growth rate is relatively minor, i.e., a few percent chirp yields few percent changes in the growth rates. Relation of these results to recent experiments is discussed.

  9. High intensity ion beams in rf undulator linac

    Directory of Open Access Journals (Sweden)

    E. S. Masunov

    2008-07-01

    Full Text Available The possibility of using a radio frequency undulator field to accelerate a high intensity ion beam in a linac is discussed. Such an accelerator can be realized using the periodical interdigital H-type resonator structure. The accelerating force is produced by an electric field which is a combination of two or more spatial harmonics, none of them being synchronous with the ion beam. The value of this force is proportional to the squared charge. The equations of motion in Hamiltonian form are derived by means of smooth approximation. The analysis of the 3D effective potential function allows finding the conditions of the beam focusing and acceleration. Two ways to increase ion beam intensity are considered: (i to enlarge beam cross section; (ii to neutralize the beam space charge by accelerating ions with opposite charge signs within the same bunch. The basic results are confirmed by a numerical simulation.

  10. Short-pulse high intensity laser thin foil interaction

    Science.gov (United States)

    Audebert, Patrick

    2003-10-01

    The technology of ultrashort pulse laser generation has progressed to the point that optical pulses larger than 10 J, 300 fs duration or shorter are routinely produced. Such pulses can be focused to intensities exceeding 10^18 W/cm^2. With high contrast pulses, these focused intensities can be used to heat solid matter to high temperatures with minimal hydrodynamic expansion, producing an extremely high energy-density state of matter for a short period of time. This high density, high temperature plasma can be studied by x-ray spectroscopy. We have performed experiments on thin foils of different elements under well controlled conditions at the 100 Terawatt laser at LULI to study the characteristics X-ray emission of laser heated solids. To suppress the ASE effect, the laser was frequency doubled. S-polarized light with a peak intensity of 10^19W/cm^2 was used to minimize resonance absorption. To decrease the effect of longitudinal temperature gradients very thin (800 μ) aluminum foil targets were used. We have also studied the effect of radial gradient by limiting the measured x-ray emission zone using 50μ or 100μ pinhole on target. The spectra, in the range 7-8Å, were recorded using a conical crystal spectrometer coupled to a 800 fs resolution streak camera. A Fourier Domain Interferometry (FDI) of the back of the foil was also performed providing a measurement of the hydrodynamic expansion as function of time for each shot. To simulate the experiment, we used the 1D hydrodynamic code FILM with a given set of plasma parameter (ρ, Te) as initial conditions. The X-ray emission was calculated by post processing hydrodynamic results with a collisional-radiative model which uses super-configuration average atomic data. The simulation reproduces the main features of the experimental time resolved spectrum.

  11. The development of a high intensity dance performance fitness test.

    Science.gov (United States)

    Redding, Emma; Weller, Peter; Ehrenberg, Shantel; Irvine, Sarah; Quin, Edel; Rafferty, Sonia; Wyon, Matthew; Cox, Carol

    2009-01-01

    While there is currently a validated dance-specific exercise method of measuring aerobic fitness, no such test has been developed to measure high intensity capabilities in dance. The purpose of this study was to initiate an intermittent high intensity dance-specific fitness test. The test was designed to be able to observe changes in heart rate (HR), thereby allowing for a measurement of physical fitness at high intensities. Sixteen professional dancers (4 males and 12 females) volunteered to take part in this study. The fitness test protocol consists of movements that are representative of contemporary dance, and contains exercise and rest periods that mimic the intermittent nature of dance. The participants performed four trials. The physiological variables measured were HR (b.min(-1)) for each one minute bout of the four minute test for all trials, oxygen uptake (VO(2)) throughout the test, and end blood lactate (BLa mmol.L) for each trial. In addition, five of the participants undertook a maximal oxygen uptake treadmill test, and the scores obtained were compared with those from the dance test. Results show HR consistency across each one minute bout of the test and across each of the four trials of testing for all participants, indicating that the test is reliable. There was good reliability between bouts of each trial (typical error as % of CV = 1.5), intraclass "r" = 0.8, and good reliability between the four trials (typical error as % of CV = 2.1), intraclass "r" = 0.82. There were no significant differences between the maximal VO(2) and BLa scores established in the treadmill and dance tests, demonstrating validity. Thus, the results of this study indicate that the high intensity dance-specific test is a reliable and valid means of assessing and monitoring the cardiovascular fitness of dancers. The test allows dancers to be assessed within an environment that they are accustomed to (the studio), using a mode of exercise that is relevant (dance), and it is

  12. The different effects of high intensity interval training and moderate intensity interval training for weightlessness countermeasures

    Science.gov (United States)

    Wang, Lin-Jie; Cheng, Tan; Zhi-Li, Li; Hui-juan, Wang; Wen-juan, Chen; Jianfeng, Zhang; Desheng, Wang; Dongbin, Niu; Qi, Zhao; Chengjia, Yang; Yanqing, Wang

    High intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. But the difference between high intensity interval training and moderate intensity interval training (MIIT) in simulated weightlessness still has not been well studied. This study sought to characterize the difference between 6 weeks high intensity interval training and moderate intensity interval training under reduced weight (RW) gait training device and zero-gravity locomotion system (ZLS). Twenty-three subjects (14M/4F, 32.5±4.5 years) volunteered to participate. They were divided into three groups, that were MITT (alternating 2 min at 40% VO _{2} peak and 2 min at 60% VO _{2} peak for 30min, five days per week) RW group (n=8), HITT (alternating 2 min at 40% VO _{2} peak and 2 min at 90% VO _{2} peak for 30min, three days per week) RW group (n=8) and HITT ZLS group (n=7). The Z-axis load used in RW group was 80% body weight (BW) and in ZLS was 100% BW. Cardiopulmonary function was measured before, after 4-week training and after 6-week training. Isokinetic knee extension-flexion test at 60(°) deg/s and 180(°) deg/s were performed before and after the 6-week training, and isometric knee extension-flexion test at 180(°) deg/s was also examined at the same time. It was found that the VO _{2} peaks, metabolic equivalent (MET), Speedmax and respiratory exchange ratio (RER) were significantly increased after 4 and 6-week training in all three groups and no significant group difference were detected. The peak torque at 60(°) deg/s for right knee flexion were significantly increased after 6 week-training in all three groups, and only in HITT RW group the total power at 60(°) deg/s for right knee flexion enhanced. The total power and average power at 60(°) deg/s for right knee extension decreased significantly after 6-week training in all three groups. The peak torque at 60(°) deg/s for right knee extension in MIIT RW group was

  13. High Performance Human Face Recognition using Independent High Intensity Gabor Wavelet Responses: A Statistical Approach

    CERN Document Server

    Kar, Arindam; Basu, Dipak Kumar; Nasipuri, Mita; Kundu, Mahantapas

    2011-01-01

    In this paper, we present a technique by which high-intensity feature vectors extracted from the Gabor wavelet transformation of frontal face images, is combined together with Independent Component Analysis (ICA) for enhanced face recognition. Firstly, the high-intensity feature vectors are automatically extracted using the local characteristics of each individual face from the Gabor transformed images. Then ICA is applied on these locally extracted high-intensity feature vectors of the facial images to obtain the independent high intensity feature (IHIF) vectors. These IHIF forms the basis of the work. Finally, the image classification is done using these IHIF vectors, which are considered as representatives of the images. The importance behind implementing ICA along with the high-intensity features of Gabor wavelet transformation is twofold. On the one hand, selecting peaks of the Gabor transformed face images exhibit strong characteristics of spatial locality, scale, and orientation selectivity. Thus these...

  14. The effect of progressive high-intensity inspiratory muscle training and fixed high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients

    OpenAIRE

    Jung, Ju-hyeon; Kim, Nan-soo

    2015-01-01

    [Purpose] This study investigated the effects of progressive load and fixed load high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients. [Subjects] Twenty-one stroke patients were assigned to one of three groups: progressive load high-intensity inspiratory muscle training (n = 8), fixed load high-intensity inspiratory muscle training (n = 6), and controls (n = 7). [Methods] The progressive load and fixed load high-intensity inspiratory muscle tra...

  15. Effects of intensity and duration in aerobic high-intensity interval training in highly trained junior cross-country skiers.

    Science.gov (United States)

    Sandbakk, Øyvind; Sandbakk, Silvana B; Ettema, Gertjan; Welde, Boye

    2013-07-01

    The purpose of this study was to test whether a long duration of aerobic high-intensity interval training is more effective than shorter intervals at a higher intensity in highly trained endurance athletes. The sample comprised of 12 male and 9 female, national-level, junior cross-country skiers (age, 17.5 ± 0.4 years, maximal oxygen uptake (V[Combining Dot Above]O2max): 67.4 ± 7.7 ml min kg), who performed 8-week baseline and 8-week intervention training periods on dry land. During the intervention period, a short-interval group (SIG, n = 7) added 2 weekly sessions with short duration intervals (2- to 4-minute bouts, total duration of 15-20 minutes), a long-interval group (LIG; n = 7) added 2 weekly sessions with long duration intervals (5- to 10-minute bouts, total duration of 40-45 minutes). The interval sessions were performed with the athletes' maximal sustainable intensity. A control group (CG; n = 7) added 2 weekly sessions with low-intensity endurance training at 65-74% of maximal heart rate. Before and after the intervention period, the skiers were tested for time-trial performance on 12-km roller-ski skating and 7-km hill run. V[Combining Dot Above]O2max and oxygen uptake at the ventilatory threshold (V[Combining Dot Above]O2VT) were measured during treadmill running. After the intervention training period, the LIG-improved 12-km roller ski, 7-km hill run, V[Combining Dot Above]O2max, and V[Combining Dot Above]O2VT by 6.8 ± 4.0%, 4.8 ± 2.6%, 3.7 ± 1.6%, and 5.8 ± 3.3%, respectively, from pre- to posttesting, and improved both performance tests and V[Combining Dot Above]O2VT when compared with the SIG and the CG (all p < 0.05). The SIG improved V[Combining Dot Above]O2max by 3.5 ± 3.2% from pre- to posttesting (p < 0.05), whereas the CG remained unchanged. As hypothesized, a long duration of aerobic high-intensity interval training improved endurance performance and oxygen uptake at the ventilatory threshold more than shorter intervals at a higher

  16. Extremely high-intensity laser interactions with fundamental quantum systems

    CERN Document Server

    Di Piazza, A; Hatsagortsyan, K Z; Keitel, C H

    2011-01-01

    The field of laser-matter interaction traditionally deals with the response of atoms, molecules and plasmas to an external light wave. However, the recent sustained technological progress is opening the possibility of employing intense laser radiation to prompt or substantially influence physical processes beyond atomic-physics energy scales. Available optical laser intensities exceeding $10^{22}\\;\\text{W/cm$^2$}$ can push the fundamental light-electron interaction to the extreme limit where radiation-reaction effects dominate the electron dynamics, can shed light on the structure of the quantum vacuum and can prime the creation of particles like electrons, muons and pions and the corresponding antiparticles. Also, novel sources of intense coherent high-energy photons and laser-based particle colliders can pave the way to nuclear quantum optics and can even allow for potential discovery of new particles beyond the Standard Model. These are the main topics of the present article, which is devoted to a review o...

  17. Backscatter imagery in Jobos Bay

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This image represents a 1x1 meter resolution backscatter mosaic of Jobos Bay, Puerto Rico (in NAD83 UTM 19 North). The backscatter values are in relative 8-bit (0 –...

  18. Electron cloud instability in high intensity proton rings

    Directory of Open Access Journals (Sweden)

    K. Ohmi

    2002-11-01

    Full Text Available An e^{-}p instability has been observed in some proton rings. The instability, which causes beam loss, limits the performance of the ring. The instability may be serious for 3 and 50 GeV proton storage rings in the Japan Proton Accelerator Research Complex (J-PARC. We study the e^{-}p instability in several high intensity proton storage rings operated in the world. This work informs J-PARC of the necessity to cure the instability, for example, by applying a TiN coating on the chamber surface.

  19. Beam instrumentation for future high intense hadron accelerators at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, M.; Hu, M.; Tassotto, G.; Thurman-Keup, R.; Scarpine, V.; Shin, S.; Zagel, J.; /Fermilab

    2008-08-01

    High intensity hadron beams of up to 2 MW beam power are a key element of new proposed experimental facilities at Fermilab. Project X, which includes a SCRF 8 GeV H{sup -} linac, will be the centerpiece of future HEP activities in the neutrino sector. After a short overview of this, and other proposed projects, we present the current status of the beam instrumentation activities at Fermilab with a few examples. With upgrades and improvements they can meet the requirements of the new beam facilities, however design and development of new instruments is needed, as shown by the prototype and conceptual examples in the last section.

  20. Development of High Intensity Beam Emittance Measurement Unit

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Three sets of High Intensity Beam Emittance Measurement Units (HIBEMUs) are being developed at Peking University. They are HIBEMU-2 (slit-wire type, one direction), HIBEMU-3 (Allison scanner type, one direction) and HIBEMU-4 (slit-wire type, two directions). For HIBEMU-2 and HIBEMU-3, more recent work has been done on software redesign in order to measure beam emittance and to draw phase diagram more efficiently and precisely. Software for control and data processing of them were developed in Labveiw environment, trying to improve calculation rationality and to offer user-friendly interface. Mechanical modification was also done for HIBEMU-3, mainly concentrating on the protection of Faraday cups from being overheated by the high intensity beam and also from interference of secondary electrons. This paper will also cover the mechanical structure as well as the software development of HIBEMU-4, which is a two-direction emittance scanner newly designed and manufactured for the high energy beam transport (HEBT) of Peking University Neutron Imaging FaciliTY (PKUNIFTY). At the end of this paper, comparison and analysis of the three HIBEMUs are given to draw forth better design of the future emittance measurement facility.

  1. High Intensity Focused Ultrasound Tumor Therapy System and Its Application

    Science.gov (United States)

    Sun, Fucheng; He, Ye; Li, Rui

    2007-05-01

    At the end of last century, a High Intensity Focused Ultrasound (HIFU) tumor therapy system was successfully developed and manufactured in China, which has been already applied to clinical therapy. This article aims to discuss the HIFU therapy system and its application. Detailed research includes the following: power amplifiers for high-power ultrasound, ultrasound transducers with large apertures, accurate 3-D mechanical drives, a software control system (both high-voltage control and low-voltage control), and the B-mode ultrasonic diagnostic equipment used for treatment monitoring. Research on the dosage of ultrasound required for tumour therapy in multiple human cases has made it possible to relate a dosage formula, presented in this paper, to other significant parameters such as the volume of thermal tumor solidification, the acoustic intensity (I), and the ultrasound emission time (tn). Moreover, the HIFU therapy system can be applied to the clinical treatment of both benign and malignant tumors in the pelvic and abdominal cavity, such as uterine fibroids, liver cancer and pancreatic carcinoma.

  2. Control of collective FSBS and backscatter SRS through plasma composition

    Science.gov (United States)

    Rose, Harvey; Lushnikov, Pavel

    2005-10-01

    Nominal NIF parameters are near the collective forward SBS (FSBS) threshold (P. M. Lushnikov and H. A. Rose, Phys. Rev. Lett. 92, 255003 (2004), ``L&R''). It will be shown that being on this instability edge can be used as a control lever: a small amount of high Z dopant may lead to qualitative change in FSBS regime at fixed laser intensity, possibly reducing backscatter instability losses (Such results have already been observed, but absent SSD, a key aspect of our theory: R. M. Stevenson et al., Phys. Plasmas 11, 2709 (2004); L. J. Suter et al., 2738, ib.). Ponderomotive FSBS regimes are determined by the parameter I=F^2( vosc / vosc ve . - ve )^2( ne / ne nc . - nc ) / ( ne / ne nc . - nc ) ν . - ν, with ν the dimensionless ion acoustic damping coefficient and F the optic f/#. Analytical results will be presented which show a decrease of I1pt's threshold value through the addition of high Z dopant to low Z plasma, owing to increased thermal contribution to FSBS. Alternatively, one may raise the threshold by managing the value of νby, e.g., adding He to SiO2. For nominal NIF parameters, a range of He fraction in SiO2 plasma is predicted to suppress backscatter SRS while maintaining control of forward SBS.

  3. Two contributions to the ratio of the mean secondary electron generation of backscattered electrons to primary electrons at high electron energy

    Science.gov (United States)

    Xie, Ai-Gen; Zhang, Chen-Yi; Zhong, Kun

    2014-02-01

    Based on the main physical processes of secondary electron emission, experimental results and the characteristics of backscattered electrons (BE), the formula was derived for describing the ratio (βangle) of the number of secondary electrons excited by the larger average angle of emission BE to the number of secondary electrons excited by the primary electrons of normal incidence. This ratio was compared to the similar ratio β obtained in the case of high energy primary electrons. According to the derived formula for βangle and the two reasons why β > 1, the formula describing the ratio βenergy of β to βangle, reflecting the effect that the mean energy of the BE WAVp0 is smaller than the energy of the primary electrons at the surface, was derived. βangle and βenergy computed using the experimental results and the deduced formulae for βangle and βenergy were analyzed. It is concluded that βangle is not dependent on atomic number z, and that βenergy decreases slowly with z. On the basis of the two reasons why β > 1, the definitions of β and βenergy and the number of secondary electrons released per primary electron, the formula for βE-energy (the estimated βenergy) was deduced. The βE-energy computed using WAVp0, energy exponent and the formula for βE-energy is in a good agreement with βenergy computed using the experimental results and the deduced formula for βenergy. Finally, it is concluded that the deduced formulae for βangle and βenergy can be used to estimate βangle and βenergy, and that the factor that WAVp0 increases slowly with atomic number z leads to the results that βenergy decreases slowly with z and β decreases slowly with z.

  4. Investigating the spectral characteristics of backscattering from heterogeneous spheroidal nuclei using broadband finite-difference time-domain simulations

    Science.gov (United States)

    Chao, Guo-Shan; Sung, Kung-Bin

    2010-02-01

    Backscattered light spectra have been used to extract size distribution of cell nuclei in epithelial tissues for noninvasive detection of precancerous lesions. In existing experimental studies, size estimation is achieved by assuming nuclei as homogeneous spheres or spheroids and fitting the measured data with models based on Mie theory. However, the validity of simplifying nuclei as homogeneous spheres has not been thoroughly examined. In this study, we investigate the spectral characteristics of backscattering from models of spheroidal nuclei under plane wave illumination using three-dimensional finite-difference time-domain (FDTD) simulation. A modulated Gaussian pulse is used to obtain wavelength dependent scattering intensity with a single FDTD run. The simulated model of nuclei consists of a nucleolus and randomly distributed chromatin condensation in homogeneous cytoplasm and nucleoplasm. The results show that backscattering spectra from spheroidal nuclei have similar oscillating patterns to those from homogeneous spheres with the diameter equal to the projective length of the spheroidal nucleus along the propagation direction. The strength of backscattering is enhanced in heterogeneous spheroids as compared to homogeneous spheroids. The degree of which backscattering spectra of heterogeneous nuclei deviate from Mie theory is highly dependent on the distribution of chromatin/nucleolus but not sensitive to nucleolar size, refractive index fluctuation or chromatin density.

  5. High-Intensity Interval Training Elicits Higher Enjoyment than Moderate Intensity Continuous Exercise.

    Science.gov (United States)

    Thum, Jacob S; Parsons, Gregory; Whittle, Taylor; Astorino, Todd A

    2017-01-01

    Exercise adherence is affected by factors including perceptions of enjoyment, time availability, and intrinsic motivation. Approximately 50% of individuals withdraw from an exercise program within the first 6 mo of initiation, citing lack of time as a main influence. Time efficient exercise such as high intensity interval training (HIIT) may provide an alternative to moderate intensity continuous exercise (MICT) to elicit substantial health benefits. This study examined differences in enjoyment, affect, and perceived exertion between MICT and HIIT. Twelve recreationally active men and women (age = 29.5 ± 10.7 yr, VO2max = 41.4 ± 4.1 mL/kg/min, BMI = 23.1 ± 2.1 kg/m2) initially performed a VO2max test on a cycle ergometer to determine appropriate workloads for subsequent exercise bouts. Each subject returned for two additional exercise trials, performing either HIIT (eight 1 min bouts of cycling at 85% maximal workload (Wmax) with 1 min of active recovery between bouts) or MICT (20 min of cycling at 45% Wmax) in randomized order. During exercise, rating of perceived exertion (RPE), affect, and blood lactate concentration (BLa) were measured. Additionally, the Physical Activity Enjoyment Scale (PACES) was completed after exercise. Results showed higher enjoyment (p = 0.013) in response to HIIT (103.8 ± 9.4) versus MICT (84.2 ± 19.1). Eleven of 12 participants (92%) preferred HIIT to MICT. However, affect was lower (pHIIT versus MICT. Although HIIT is more physically demanding than MICT, individuals report greater enjoyment due to its time efficiency and constantly changing stimulus.

  6. Application of FEL technique for constructing high-intensity, monochromatic, polarized gamma-sources at storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Saldin, E.L.; Schneidmiller, E.A.; Ulyanov, Yu.N. [Automatic Systems Corporation, Samara (Russian Federation)] [and others

    1995-12-31

    A possibility to construct high-intensity tunable monochromatic{gamma}-source at high energy storage rings is discussed. It is proposed to produce {gamma}-quanta by means of Compton backscattering of laser photons on electrons circulating in the storage. The laser light wavelength is chosen in such a way that after the scattering, the electron does not leave the separatrix. So as the probability of the scattering is rather small, energy oscillations are damped prior the next scattering. As a result, the proposed source can operate in {open_quotes}parasitic{close_quote} mode not interfering with the main mode of the storage ring operation. Analysis of parameters of existent storage rings (PETRA, ESRF, Spring-8, etc) shows that the laser light wavelength should be in infrared, {lambda}{approximately} 10 - 400 {mu}m, wavelength band. Installation at storage rings of tunable free-electron lasers with the peak and average output power {approximately} 10 MW and {approximately} 1 kW, respectively, will result in the intensity of the {gamma}-source up to {approximately} 10{sup 14}s{sup -1} with tunable {gamma}-quanta energy from several MeV up to several hundreds MeV. Such a {gamma}-source will reveal unique possibilities for precision investigations in nuclear physics.

  7. High-Intensity Sweeteners in Alternative Tobacco Products.

    Science.gov (United States)

    Miao, Shida; Beach, Evan S; Sommer, Toby J; Zimmerman, Julie B; Jordt, Sven-Eric

    2016-11-01

    Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objective of the present study was to quantify added sweeteners in smokeless tobacco products, a dissolvable product, electronic cigarette liquids and to compare with sweetener levels in confectionary products. Sweetener content of US-sourced smokeless tobacco, electronic cigarette liquid, and confectionary product samples was analyzed by liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). All smokeless products contained synthetic high intensity sweeteners, with snus and dissolvables exceeding levels in confectionary products (as much as 25-fold). All snus samples contained sucralose and most also aspartame, but no saccharin. In contrast, all moist snuff samples contained saccharin. The dissolvable sample contained sucralose and sorbitol. Ethyl maltol was the most common sweet-associated component in electronic cigarette liquids. Sweetener content was dependent on product category, with saccharin in moist snuff, an older category, sucralose added at high levels to more recently introduced products (snus, dissolvable) and ethyl maltol in electronic cigarette liquid. The very high sweetener concentrations may be necessary for the consumer to tolerate the otherwise aversive flavors of tobacco ingredients. Regulation of sweetener levels in smokeless tobacco products may be an effective measure to modify product attractiveness, initiation and use patterns. Dissolvables, snus and electronic cigarettes have been promoted as risk-mitigation products due to their relatively low content of nitrosamines and other tobacco toxicants. This study is the first to quantify high

  8. High-Intensity Sweeteners in Alternative Tobacco Products

    Science.gov (United States)

    Miao, Shida; Beach, Evan S.; Sommer, Toby J.; Zimmerman, Julie B.

    2016-01-01

    Introduction: Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objective of the present study was to quantify added sweeteners in smokeless tobacco products, a dissolvable product, electronic cigarette liquids and to compare with sweetener levels in confectionary products. Methods: Sweetener content of US-sourced smokeless tobacco, electronic cigarette liquid, and confectionary product samples was analyzed by liquid chromatography-electrospray ionization–mass spectrometry (LC-ESI-MS). Results: All smokeless products contained synthetic high intensity sweeteners, with snus and dissolvables exceeding levels in confectionary products (as much as 25-fold). All snus samples contained sucralose and most also aspartame, but no saccharin. In contrast, all moist snuff samples contained saccharin. The dissolvable sample contained sucralose and sorbitol. Ethyl maltol was the most common sweet-associated component in electronic cigarette liquids. Discussion: Sweetener content was dependent on product category, with saccharin in moist snuff, an older category, sucralose added at high levels to more recently introduced products (snus, dissolvable) and ethyl maltol in electronic cigarette liquid. The very high sweetener concentrations may be necessary for the consumer to tolerate the otherwise aversive flavors of tobacco ingredients. Regulation of sweetener levels in smokeless tobacco products may be an effective measure to modify product attractiveness, initiation and use patterns. Implications: Dissolvables, snus and electronic cigarettes have been promoted as risk-mitigation products due to their relatively low content of nitrosamines and other tobacco

  9. Longitudinal tracking studies for a high intensity proton synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Lessner, E.; Cho, Y.; Harkay, K.; Symon, K. [Argonne National Laboratory, 9700 Cass Ave., Argonne, Illinois 60439 (United States)

    1996-06-01

    Results from longitudinal tracking studies for a high intensity proton synchrotron designed for a 1-MW spallation source are presented. The machine delivers a proton beam of 0.5 mA time-averaged current at a repetition rate of 30 Hz. The accelerator is designed to have radiation levels that allow hands-on-maintenance. However, the high beam intensity causes strong space charge fields whose effects may lead to particle loss and longitudinal instabilities. The space charge fields modify the particle distribution, distort the stable bucket area and reduce the rf linear restoring force. Tracking simulations were conducted to analyze the space charge effects on the dynamics of the injection and acceleration processes and means to circumvent them. The tracking studies led to the establishment of the injected beam parameters and rf voltage program that minimized beam loss and longitudinal instabilities. Similar studies for a 10-GeV synchrotron that uses the 2-GeV synchrotron as its injector are also discussed. {copyright} {ital 1996 American Institute of Physics.}

  10. Formation of a high intensity low energy positron string

    Science.gov (United States)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  11. Use of High Intensity Focused Ultrasound for Treating Malignant Tumors

    Institute of Scientific and Technical Information of China (English)

    WenzhiChen; ZhibiaoWang; FengWu; JinBai; HuiZhu; JianzhongZou; KequanLi; FanglinXie; ZhilongWang

    2004-01-01

    OBJECTIVE To investigate the efficacy and side effects of high intensity focused ultrasound(HIFU) in the treatment of malignant solid tumors. METHODS Thirty patients who refused surgery and/or were refractory to chemotherapy were treated by HIFU alone, with the efficacy and side effects monitored as follows: observation of vital organ signs; functional assay of important organs; imaging examinations including: digital subtraction angiography (DSA), CT, MRI, single photon emission computed tomography (SPECT), large core needle biopsy, complications and metastasis. RESULTS After HIFU therapy, the vital signs remained stable and the functions of the heart, lung, kidney and liver were also normal. DSA images showed that small or larger arteries were not damaged. After a follow-up of 10-38 months(mean 23.1 months), 26 patients(87%) were alive. The volume of the tumor underwent complete regression in 10 patients. Shrinkage of the tumor volume ≥50% was observed in 13 patients. Eight of 13 patients were examined by large core needle biopsy, all showing necrosis and/or fibrosis though 3 patients(10%) had local recurrence. Two of these were retreated again by HIFU and the locally recurrent tumors were controlled. New metastases developed in 5 patients after H IFU. Two patients suffered from peripheral nerve injuriy and they have recovered during the follow-up. One patient developed skin injury. CONCLUSION High intensity focused ultrasound is effective and safe in the treatment of malignant solid tumors.

  12. Efficacy of high intensity atorvastatin versus moderate intensity atorvastatin for acute coronary syndrome patients with diabetes mellitus.

    Science.gov (United States)

    Liu, Zhi; Xu, Yueqiao; Hao, Hengjian; Yin, Chunlin; Xu, Ji; Li, Jing; Wang, Yanling; Xu, Dong

    2016-11-01

    To investigate whether more benefits can be achieved through high intensity atorvastatin compared with moderate intensity atorvastatin in acute coronary syndrome (ACS) patients with diabetes mellitus (DM). This was a randomized controlled trail. Total 591 ACS patients with DM who underwent percutaneous coronary intervention were enrolled, 297 in high intensity atorvastatin group (40mg/day) and 294 in moderate intensity atorvastatin group (20mg/day). The primary end point was one-year incidence of major adverse cardiovascular events (MACE, including cardiovascular death, spontaneous myocardial infarction, unplanned revascularization). Cox proportional hazard regression models were used to analyze the association between clinical endpoints and atorvastatin treatment. At the end of one-year, low-density lipoprotein cholesterol level was lower in high intensity group than in moderate group (1.6±0.6 vs 1.8±0.6, p=0.041). MACE in high intensity group decreased 44.5% than moderate group (8.4% vs. 14.6%, p=0.018). The adjusted hazard ratio (HR) for MACE in patients with atorvastatin 40mg/d was lower compared to patients with atorvastatin 20mg/d (HR [95% CI] 0.61 [0.36 to 0.91], p=0.026). The rates of adverse events were no significantly different between the two groups. For ACS patients with DM, high intensity atorvastatin induced better long-term outcomes compared with moderate intensity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Ultra-High Intensity Magnetic Field Generation in Dense Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Fisch, Nathaniel J. [Princeton Univ., NJ (United States)

    2014-01-08

    The main objective of this grant proposal was to explore the efficient generation of intense currents. Whereas the efficient generation of electric current in low-­energy-­density plasma has occupied the attention of the magnetic fusion community for several decades, scant attention has been paid to carrying over to high-­energy-­density plasma the ideas for steady-­state current drive developed for low-­energy-­density plasma, or, for that matter, to inventing new methodologies for generating electric current in high-­energy-­density plasma. What we proposed to do was to identify new mechanisms to accomplish current generation, and to assess the operation, physics, and engineering basis of new forms of current drive in regimes appropriate for new fusion concepts.

  14. Increased collection efficiency of LIFI high intensity electrodeless light source

    Science.gov (United States)

    Hafidi, Abdeslam; DeVincentis, Marc; Duelli, Markus; Gilliard, Richard

    2008-02-01

    Recently, RF driven electrodeless high intensity light sources have been implemented successfully in the projection display systems for HDTV and videowall applications. This paper presents advances made in the RF waveguide and electric field concentrator structures with the purpose of reducing effective arc size and increasing light collection. In addition, new optical designs are described that further improve system efficiency. The results of this work demonstrate that projection system light throughput is increased relative to previous implementations and performance is optimized for home theater and other front projector applications that maintain multi-year lifetime without re-lamping, complete spectral range, fast start times and high levels of dynamic contrast due to dimming flexibility in the light source system.

  15. Generation And Measurement Of High Contrast Ultrashort Intense Laser Pulses

    CERN Document Server

    Konoplev, O A

    2000-01-01

    In this thesis, the generation and measurement of high contrast, intense, ultrashort pulses have been studied. Various factors affecting the contrast and pulse shape of ultrashort light pulses from a chirped pulse amplification (CPA) laser system are identified. The level of contrast resulting from influence of these factors is estimated. Methods for improving and controlling the pulse shape and increasing the contrast are discussed. Ultrahigh contrast, 1-ps pulses were generated from a CPA system with no temporal structure up to eleven orders of magnitude. This is eight orders of magnitude higher contrast than the original pulse. This contrast boost was achieved using two techniques. One is the optical pulse cleaning based on the nonlinear birefringence of the chirping fiber and applied to the pulses before amplification. The other is the fast saturable absorber. The fast saturable absorber was placed after amplification and compression of the pulse. The measurements of high-contrast, ultrashort pulse with h...

  16. Ultra-High Intensity Magnetic Field Generation in Dense Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Fisch, Nathaniel J

    2014-01-08

    I. Grant Objective The main objective of this grant proposal was to explore the efficient generation of intense currents. Whereasthefficient generation of electric current in low-­energy-­density plasma has occupied the attention of the magnetic fusion community for several decades, scant attention has been paid to carrying over to high-­energy-­density plasma the ideas for steady-­state current drive developed for low-­energy-­density plasma, or, for that matter, to inventing new methodologies for generating electric current in high-­energy-­density plasma. What we proposed to do was to identify new mechanisms to accomplish current generation, and to assess the operation, physics, and engineering basis of new forms of current drive in regimes appropriate for new fusion concepts.

  17. Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Kristie L.; Wang, Anbo; Pickrell, Gary R.

    2006-11-14

    This report summarizes technical progress during the program “Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to use technology recently invented at Virginia Tech to develop and demonstrate the application of self-calibrating optical fiber temperature and pressure sensors to several key energy-intensive industries where conventional, commercially available sensors exhibit greatly abbreviated lifetimes due primarily to environmental degradation. A number of significant technologies were developed under this program, including • a laser bonded silica high temperature fiber sensor with a high temperature capability up to 700°C and a frequency response up to 150 kHz, • the world’s smallest fiber Fabry-Perot high temperature pressure sensor (125 x 20 μm) with 700°C capability, • UV-induced intrinsic Fabry-Perot interferometric sensors for distributed measurement, • a single crystal sapphire fiber-based sensor with a temperature capability up to 1600°C. These technologies have been well demonstrated and laboratory tested. Our work plan included conducting major field tests of these technologies at EPRI, Corning, Pratt & Whitney, and Global Energy; field validation of the technology is critical to ensuring its usefulness to U.S. industries. Unfortunately, due to budget cuts, DOE was unable to follow through with its funding commitment to support Energy Efficiency Science Initiative projects and this final phase was eliminated.

  18. Outcomes of exertional rhabdomyolysis following high-intensity resistance training.

    Science.gov (United States)

    Huynh, A; Leong, K; Jones, N; Crump, N; Russell, D; Anderson, M; Steinfort, D; Johnson, D F

    2016-05-01

    High-intensity resistance training (HIRT) programmes are increasingly popular amongst personal trainers and those attending gymnasiums. We report the experience of exertional rhabdomyolysis (ER) at two tertiary hospitals in Melbourne, Australia. To compare the clinical outcomes of ER with other causes of rhabdomyolysis. Retrospective cross-sectional study of patients presenting with a serum creatine kinase (CK) of greater than 25 000 units/L from 1 September 2013 to 31 August 2014 at two tertiary referral hospitals in Melbourne, Australia. Records were examined to identify care measures implemented during hospital stay, clinical outcomes during admission and on subsequent follow up. Thirty four cases of rhabdomyolysis with a CK of greater than 25 000 units/L (normal range: 20-180 units/L) were identified during the 12-month study period. Twelve of the 34 cases (35%) had ER with 10 of 12 related to HIRT. No acute kidney injury, intensive care admission or death were seen among those with ER. All cases were managed conservatively, with 11 admitted and 9 receiving intravenous fluids only. In contrast, patients with rhabdomyolysis from other causes experienced significantly higher rates of intensive care admission (64%, P = 0.0002), acute kidney injury (82%, P = 0.0001) and death (27%, P = 0.069). ER resulting from HIRT appears to have a benign course compared with rhabdomyolysis of other aetiologies in patients with a serum CK greater than 25 000 units/L. Conservative management of ER appears to be adequate, although this requires confirmation in future prospective studies. © 2016 Royal Australasian College of Physicians.

  19. Application of High Intensity THz Pulses for Gas High Harmonic Generation

    CERN Document Server

    Balogh, Emeric; Hebling, János; Dombi, Péter; Farkas, Győző; Varjú, Katalin

    2013-01-01

    The main effects of an intense THz pulse on gas high harmonic generation are studied via trajectory analysis on the single atom level. Spectral and temporal modifications to the generated radiation are highlighted.

  20. Semicircular Canal Pressure Changes During High-intensity Acoustic Stimulation.

    Science.gov (United States)

    Maxwell, Anne K; Banakis Hartl, Renee M; Greene, Nathaniel T; Benichoux, Victor; Mattingly, Jameson K; Cass, Stephen P; Tollin, Daniel J

    2017-08-01

    Acoustic stimulation generates measurable sound pressure levels in the semicircular canals. High-intensity acoustic stimuli can cause hearing loss and balance disruptions. To examine the propagation of acoustic stimuli to the vestibular end-organs, we simultaneously measured fluid pressure in the cochlea and semicircular canals during both air- and bone-conducted sound presentation. Five full-cephalic human cadaveric heads were prepared bilaterally with a mastoidectomy and extended facial recess. Vestibular pressures were measured within the superior, lateral, and posterior semicircular canals, and referenced to intracochlear pressure within the scala vestibuli with fiber-optic pressure probes. Pressures were measured concurrently with laser Doppler vibrometry measurements of stapes velocity during stimulation with both air- and bone-conduction. Stimuli were pure tones between 100 Hz and 14 kHz presented with custom closed-field loudspeakers for air-conducted sounds and via commercially available bone-anchored device for bone-conducted sounds. Pressures recorded in the superior, lateral, and posterior semicircular canals in response to sound stimulation were equal to or greater in magnitude than those recorded in the scala vestibuli (up to 20 dB higher). The pressure magnitudes varied across canals in a frequency-dependent manner. High sound pressure levels were recorded in the semicircular canals with sound stimulation, suggesting that similar acoustical energy is transmitted to the semicircular canals and the cochlea. Since these intralabyrinthine pressures exceed intracochlear pressure levels, our results suggest that the vestibular end-organs may also be at risk for injury during exposure to high-intensity acoustic stimuli known to cause trauma in the auditory system.

  1. Proceedings of the third ICFA mini-workshop on high intensity, high brightness hadron accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Roser, T.

    1997-11-01

    The third mini-workshop on high intensity, high brightness hadron accelerators was held at Brookhaven National Laboratory on May 7-9, 1997 and had about 30 participants. The workshop focussed on rf and longitudinal dynamics issues relevant to intense and/or bright hadron synchrotrons. A plenary session was followed by four sessions on particular topics. This document contains copies of the viewgraphs used as well as summaries written by the session chairs.

  2. Proceedings of the third ICFA mini-workshop on high intensity, high brightness hadron accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Roser, T.

    1997-11-01

    The third mini-workshop on high intensity, high brightness hadron accelerators was held at Brookhaven National Laboratory on May 7-9, 1997 and had about 30 participants. The workshop focussed on rf and longitudinal dynamics issues relevant to intense and/or bright hadron synchrotrons. A plenary session was followed by four sessions on particular topics. This document contains copies of the viewgraphs used as well as summaries written by the session chairs.

  3. Blood coagulation using High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Nguyen, Phuc V.; Oh, Junghwan; Kang, Hyun Wook

    2014-03-01

    High Intensity Focused Ultrasound (HIFU) technology provides a feasible method of achieving thermal coagulation during surgical procedures. One of the potential clinical benefits of HIFU can induce immediate hemostasis without suturing. The objective of this study was to investigate the efficiency of a HIFU system for blood coagulation on severe vascular injury. ngHIFU treatment was implemented immediately after bleeding in artery. The ultrasound probe was made of piezoelectric material, generating a central frequency of 2.0 MHz as well as an ellipsoidal focal spot of 2 mm in lateral dimension and 10 mm in axial dimension. Acoustic coagulation was employed on a perfused chicken artery model in vitro. A surgical incision (1 to 2 mm long) was made with a scapel on the arterial wall, and heparinized autologous blood was made to leak out from the incision with a syringe pump. A total of 5 femoral artery incisions was treated with the HIFU beam. The intensity of 4500 W/cm2 at the focus was applied for all treatments. Complete hemostasis was achieved in all treatments, along with the treatment times of 25 to 50 seconds. The estimated intraoperative blood loss was from 2 to 5 mL. The proposed HIFU system may provide an effective method for immediate blood coagulation for arteries and veins in clinical applications.

  4. Back-scatter analysis based algorithms for increasing transmission through highly-scattering random media using phase-only modulated wavefronts

    CERN Document Server

    Jin, Curtis; Michielssen, Eric; Rand, Stephen

    2014-01-01

    Recent theoretical and experimental advances have shed light on the existence of so-called `perfectly transmitting' wavefronts with transmission coefficients close to 1 in strongly backscattering random media. These perfectly transmitting eigen-wavefronts can be synthesized by spatial amplitude and phase modulation. Here, we consider the problem of transmission enhancement using phase-only modulated wavefronts. We develop physically realizable iterative and non-iterative algorithms for increasing the transmission through such random media using backscatter analysis. We theoretically show that, despite the phase-only modulation constraint, the non-iterative algorithms will achieve at least about 25$\\pi$% or about 78.5% transmission assuming there is at least one perfectly transmitting eigen-wavefront and that the singular vectors of the transmission matrix obey a maximum entropy principle so that they are isotropically random. We numerically analyze the limits of phase-only modulated transmission in 2-D with f...

  5. Pedalling rate affects endurance performance during high-intensity cycling

    DEFF Research Database (Denmark)

    Nielsen, Jens Steen; Hansen, Ernst Albin; Sjøgaard, Gisela

    2004-01-01

    , such as muscle fibre type composition and power reserve, relate to endurance time. Twenty males underwent testing to determine their maximal oxygen uptake (VO(2max)), power output corresponding to 90% of VO(2max) at 80 rpm (W90), FCPR at W90, percentage of slow twitch muscle fibres (% MHC I), maximal leg power...... time was negatively related to VO(2max), W90 and % MHC I, while positively related to power reserve. In conclusion, at group level, endurance time was longer at FCPR and at a pedalling rate 25% lower compared to a pedalling rate 25% higher than FCPR. Further, inter-individual physiological variables......The purpose of this study into high-intensity cycling was to: (1) test the hypothesis that endurance time is longest at a freely chosen pedalling rate (FCPR), compared to pedalling rates 25% lower (FCPR-25) and higher (FCPR+25) than FCPR, and (2) investigate how physiological variables...

  6. Vortex dynamics and shear layer instability in high intensity cyclotrons

    CERN Document Server

    Cerfon, Antoine J

    2016-01-01

    We show that the space charge dynamics of high intensity beams in the plane perpendicular to the magnetic field in cyclotrons is described by the two-dimensional Euler equations for an incompressible fluid. This analogy with fluid dynamics gives a unified and intuitive framework to explain the beam spiraling and beam break up behavior observed in experiments and in simulations. In particular, we demonstrate that beam break up is the result of a classical instability occurring in fluids subject to a sheared flow. We give scaling laws for the instability and predict the nonlinear evolution of beams subject to it. Our work suggests that cyclotrons may be uniquely suited for the experimental study of shear layers and vortex distributions that are not achievable in Penning-Malmberg traps.

  7. Simplified shielding calculation system for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Masumura, Tomomi; Nakashima, Hiroshi; Nakane, Yoshihiro; Sasamoto, Nobuo [Center for Neutron Science, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-06-01

    A simplified shielding calculation system is developed for applying conceptual shielding design of facilities in the joint project for high-intensity proton accelerators. The system is composed of neutron transmission calculation part for bulk shielding using simplified formulas: Moyer model and Tesch's formula, and neutron skyshine calculation part using an empirical formula: Stapleton's formula. The system is made with the Microsoft Excel software for user's convenience. This report provides a manual for the system as well as calculation conditions used in the calculation such as Moyer model's parameters. In this report preliminary results based on data at December 8, 1999, are also shown as an example. (author)

  8. Repeated high-intensity exercise in a professional rugby league.

    Science.gov (United States)

    Austin, Damien J; Gabbett, Tim J; Jenkins, David J

    2011-07-01

    The primary aim of this study was to identify and describe the frequency and duration of repeated high-intensity exercise (RHIE) bouts in Australian professional rugby league (National Rugby League) and whether these occurred at critical times during a game. Time motion analysis was used during 5 competition matches; 1 player from 3 positional groups (hit-up forward, adjustable, and outside back) was analyzed in each match. The ranges of RHIE bouts for the 3 positional groups were hit-up forwards 9-17, adjustables 2-8, and outside backs 3-7. Hit-up forwards were involved in a significantly greater number of RHIE bouts (p rugby league players are likely to encounter.

  9. Fast damping in mismatched high intensity beam transportation

    Directory of Open Access Journals (Sweden)

    V. Variale

    2001-08-01

    Full Text Available A very fast damping of beam envelope oscillation amplitudes was recently observed in simulations of high intensity beam transport, through periodic FODO cells, in mismatched conditions [V. Variale, Nuovo Cimento Soc. Ital. Fis. 112A, 1571–1582 (1999 and T. Clauser et al., in Proceedings of the Particle Accelerator Conference, New York, 1999 (IEEE, Piscataway, NJ, 1999, p. 1779]. A Landau damping mechanism was proposed at the origin of observed effect. In this paper, to further investigate the source of this fast damping, extensive simulations have been carried out. The results presented here support the interpretation of the mechanism at the origin of the fast damping as a Landau damping effect.

  10. New Zealand Blackcurrant Extract Improves High-Intensity Intermittent Running.

    Science.gov (United States)

    Perkins, Ian Craig; Vine, Sarah Anne; Blacker, Sam David; Willems, Mark Elisabeth Theodorus

    2015-10-01

    We examined the effect of New Zealand blackcurrant (NZBC) extract on high-intensity intermittent running and postrunning lactate responses. Thirteen active males (age: 25 ± 4 yrs, height: 1.82 ± 0.07 m, body mass: 81 ± 14 kg, VO2max: 56 ± 4 ml·kg-1·min-1, vVO2max: 17.6 ± 0.8 km·h-1) performed a treadmill running protocol to exhaustion, which consisted of stages with 6 × 19 s of sprints with 15 s of low-intensity running between sprints. Interstage rest time was 1 min and stages were repeated with increasing sprint speeds. Subjects consumed capsuled NZBC extract (300 mg·day-1 CurraNZ; containing 105 mg anthocyanin) or placebo for 7 days (double-blind, randomized, crossover design, wash-out at least 14 days). Blood lactate was collected for 30 min postexhaustion. NZBC increased total running distance by 10.6% (NZBC: 4282 ± 833 m, placebo: 3871 ± 622 m, p = .02), with the distance during sprints increased by 10.8% (p = .02). Heart rate, oxygen uptake, lactate and rating of perceived exertion were not different between conditions for the first 4 stages completed by all subjects. At exhaustion, blood lactate tended to be higher for NZBC (NZBC: 6.01 ± 1.07 mmol·L-1, placebo: 5.22 ± 1.52 mmol·L-1, p = .07). There was a trend for larger changes in lactate following 15 min (NZBC: -2.89 ± 0.51 mmol·L-1, placebo: -2.46 ± 0.39 mmol·L-1, p = .07) of passive recovery. New Zealand blackcurrant extract (CurraNZ) may enhance performance in sports characterized by high-intensity intermittent exercise as greater distances were covered with repeated sprints, there was higher lactate at exhaustion, and larger changes in lactate during early recovery after repeated sprints to exhaustion.

  11. Nanobiotechnology promotes noninvasive high-intensity focused ultrasound cancer surgery.

    Science.gov (United States)

    Chen, Yu; Chen, Hangrong; Shi, Jianlin

    2015-01-07

    The successful cancer eradication in a noninvasive manner is the ultimate objective in the fight against cancer. As a "bloodless scalpel," high-intensity focused ultrasound (HIFU) is regarded as one of the most promising and representative noninvasive therapeutic modalities for cancer surgery. However, large-scale clinical applications of HIFU are still in their infancy because of critical efficiency and safety issues which remain to be solved. Fortunately, recently developed nanobiotechnology provides an alternative efficient approach to improve such important issues in HIFU, especially for cancer therapy. This Research News presents the very recent exciting progresses on the elaborate design and fabrication of organic, inorganic, and organic/inorganic hybrid nanoparticles for enhancing the HIFU ablation efficiency against tumor tissues. It is highly expected that this Research News can arouse more extensive research enthusiasm on the development of functional nanomaterials for highly efficient HIFU-based synergistic therapy, which will give a promising noninvasive therapeutic modality for the successful cancer therapy with minimal damage to surrounding normal tissues, due to the noninvasive and site-specific therapeutic features of HIFU.

  12. Bunching high intensity proton beams with a CH-DTL

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Malte; Claessens, Christine; Heilmann, Manuel; Hinrichs, Ole; Koser, Daniel; Meusel, Oliver; Noll, Daniel; Podlech, Holger; Ratzinger, Ulrich; Seibel, Anja [Institut fuer Angewandte Physik, Goethe-Universitaet Frankfurt am Main (Germany)

    2014-07-01

    The Frankfurt Neutron Source at the Stern-Gerlach-Zentrum (FRANZ) will provide ultra short neutron pulses at high intensities and repetition rates. The facility is under construction with an expected first beam by the end of 2014. A 5-Gap CH rebuncher is installed behind a coupled RFQ/IH-DTL combination at the end of the LINAC section between two magnetic quadrupole triplets. It will be used for varying the final energy between 1.8 and 2.2 MeV, as well as for focusing the proton beam bunch longitudinally, to compensate RF defocusing effects and huge space charge forces at currents up to 200 mA at the final stage of extension. Therefore high current beam dynamic simulations are in progress. They include benchmarking of different beam dynamic codes like LORASR, TraceWin and Bender (a new PIC tracking code developed at IAP), as well as validating the results by measurements. Detailed error tolerance studies, thermal simulations and examination of multipole field impact, due to the cavity geometry, are also done. Furthermore, this CH rebuncher serves as prototype for CH cavity operation at MYRRHA (Belgium), an Accelerator Driven System (ADS) for transmutation of high level nuclear waste. After copper-plating the cavity, RF conditioning will start in spring 2014.

  13. Nonlinear frequency shift in Raman backscattering and its implications for plasma diagnostics

    Science.gov (United States)

    Kaganovich, D.; Hafizi, B.; Palastro, J. P.; Ting, A.; Helle, M. H.; Chen, Y.-H.; Jones, T. G.; Gordon, D. F.

    2016-12-01

    Raman backscattered radiation of intense laser pulses in plasmas is investigated for a wide range of intensities relevant to laser wakefield acceleration. The weakly nonlinear dispersion relation for Raman backscattering predicts an intensity and density dependent frequency shift that is opposite to that suggested by a simple relativistic consideration. This observation has been benchmarked against experimental results, providing a novel diagnostic for laser-plasma interactions.

  14. Nonlinear Frequency Shift in Raman Backscattering and its Implications for Plasma Diagnostics

    CERN Document Server

    Kaganovich, D; Palastro, J P; Ting, A; Helle, M H; Chen, Y -H; Jones, T G; Gordon, D F

    2016-01-01

    Raman backscattered radiation of intense laser pulses in plasma is investigated for a wide range of intensities relevant to laser wakefield acceleration. The weakly nonlinear dispersion relation for Raman backscattering predicts an intensity and density dependent frequency shift that is opposite to that suggested by a simple relativistic consideration. This observation has been benchmarked against experimental results, providing a novel diagnostic for laser-plasma interactions.

  15. Results from the Daresbury Compton backscattering X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Laundy, D. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire, WA4 4AD (United Kingdom); Priebe, G. [Max Born Institute, Max-Born-Strasse 2A, 12489 Berlin, DE (Germany); Jamison, S.P. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire, WA4 4AD (United Kingdom); Graham, D.M. [The Photon Science Institute, The University of Manchester, Manchester M13 9PL (United Kingdom); Phillips, P.J. [STFC Rutherford Appleton Laboratory, Chilton, Didcot, OX11 0QX (United Kingdom); Smith, S.L.; Saveliev, Y. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire, WA4 4AD (United Kingdom); Vassilev, S. [The University of Nottingham, Nottingham, NG7 2RD (United Kingdom); Seddon, E.A., E-mail: elaine.seddon@stfc.ac.uk [The Photon Science Institute, The University of Manchester, Manchester M13 9PL (United Kingdom)

    2012-10-11

    The Daresbury Compton Backscattering X-ray Source uses a high power Ti Sapphire laser interacting in head on geometry with electron bunches in the ALICE energy recovery linear accelerator. X-ray photons with peak energy of 21 keV were generated with the accelerator operating at an energy of 29.6 MeV. The spatial profile of the X-rays emitted near the electron beam axis was measured. The characteristics of the X-ray yield measured as a function of relative timing between the laser pulse and the interacting electron bunch was found to be consistent with the modelled intensity behaviour using measured electron and laser beam parameters.

  16. Observation of fine particle aggregating behavior induced by high intensity conditioning using high speed CCD

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The aggregating behavior between bubbles and particles induced by high intensity conditioning (HIC) was studied using high speed CCD technique. Bubble size measurement was conducted, and the attachment behavior between bubbles and particles in HIC cell and flotation cell were observed. The results show that in HIC cell, high intensity conditioning creates an advantage environment for the formation of small size bubble due to hydrodynamic cavitations, and these fine bubbles have high probability of bubble-particle collision,which will enhance fine particle flotation. The bubble-particle attachment experiments indicate that in high intensity conditioning cell, a lot of fine bubbles are produced in situ on the surface of fine particles, and most of fine particles are aggregated under the bridging action of fine bubbles. The observation of bubble-particle interaction in flotation cell illustrates that aggregates created by HIC can be loaded more easily by big air bubble in flotation cell than those created by normal conditioning.

  17. Simulation-guided optimization of small-angle analyzer geometry in the neutron backscattering spectrometer SPHERES.

    Science.gov (United States)

    Wuttke, Joachim; Zamponi, Michaela

    2013-11-01

    The resolution of neutron backscattering spectrometers deteriorates at small scattering angles where analyzers deviate from exact backscattering. By reducing the azimuth angle range of the analyzers, the resolution can be improved with little loss of peak intensity. Measurements at the spectrometer SPHERES are in excellent agreement with simulations, which proves the dominance of geometric effects.

  18. Simulation-guided optimization of small-angle analyzer geometry in the neutron backscattering spectrometer SPHERES

    Energy Technology Data Exchange (ETDEWEB)

    Wuttke, Joachim; Zamponi, Michaela [Forschungszentrum Jülich GmbH, Jülich Centre for Neutron Science at MLZ, Lichtenbergstraße 1, 85747 Garching (Germany)

    2013-11-15

    The resolution of neutron backscattering spectrometers deteriorates at small scattering angles where analyzers deviate from exact backscattering. By reducing the azimuth angle range of the analyzers, the resolution can be improved with little loss of peak intensity. Measurements at the spectrometer SPHERES are in excellent agreement with simulations, which proves the dominance of geometric effects.

  19. Seabed maps showing topography, ruggedness, backscatter intensity, sediment mobility, and the distribution of geologic substrates in Quadrangle 6 of the Stellwagen Bank National Marine Sanctuary Region offshore of Boston, Massachusetts

    Science.gov (United States)

    Valentine, Page C.; Gallea, Leslie B.

    2015-11-10

    The U.S. Geological Survey (USGS), in cooperation with the National Oceanic and Atmospheric Administration's National Marine Sanctuary Program, has conducted seabed mapping and related research in the Stellwagen Bank National Marine Sanctuary (SBNMS) region since 1993. The area is approximately 3,700 square kilometers (km2) and is subdivided into 18 quadrangles. Seven maps, at a scale of 1:25,000, of quadrangle 6 (211 km2) depict seabed topography, backscatter, ruggedness, geology, substrate mobility, mud content, and areas dominated by fine-grained or coarse-grained sand. Interpretations of bathymetric and seabed backscatter imagery, photographs, video, and grain-size analyses were used to create the geology-based maps. In all, data from 420 stations were analyzed, including sediment samples from 325 locations. The seabed geology map shows the distribution of 10 substrate types ranging from boulder ridges to immobile, muddy sand to mobile, rippled sand. Mapped substrate types are defined on the basis of sediment grain-size composition, surface morphology, sediment layering, the mobility or immobility of substrate surfaces, and water depth range. This map series is intended to portray the major geological elements (substrates, topographic features, processes) of environments within quadrangle 6. Additionally, these maps will be the basis for the study of the ecological requirements of invertebrate and vertebrate species that utilize these substrates and guide seabed management in the region.

  20. Investigations on transport and storage of high ion beam intensities

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Ninad Shrikrishna

    2009-08-25

    In the framework of this thesis the intense low energy ion beam transport was investigated. Especially, the beam transport in toroidal magnetic field configurations was discussed, as it may allow the accumulation of high intensive beams in the future. One of the specific tasks is to design an injection system that can be used for the proposed low energy accumulator ring. A simulation code (TBT) was written to describe the particle motion in curved segments. Particle in Cell techniques were utilized to simulate a multi particle dynamics. A possibility of reading an external data file was made available so that a measured distribution can be used to compare simulation results with measured ones. A second order cloud in cell method was used to calculate charge density and in turn to solve Poisson's equation. Further simulations were performed to study the self field effects on beam transport. Experiments were performed to compare the simulation results and gain practical experience. The preparatory experiments consisted of building and characterization of the ion source in a first step. Along with the momentum spectrometer and emittance scanner the beam properties were studied. Low mass ion beams He{sup +} and mixed p, H{sup 2+}, H{sup 3+} beams were analyzed. In the second stage, beams were transported through a solenoid and the phase space distribution was measured as a function of the magnetic field for different beam energies. The phase-space as distributions measured in a first stage were simulated backward and then again forward transported through the solenoid. The simulated results were then compared with the measured distribution. The LINTRA transport program was used. The phase-space distribution was further simulated for transport experiments in a toroidal magnetic field. The transport program that was used to simulate the beam in the toroid was also used to design the injection system. The injection system with its special field configurations was

  1. High-order harmonic generation at high laser intensities beyond the tunnel regime

    CERN Document Server

    Pérez-Hernández, J A; Lewenstein, M; Zaïr, A; Roso, L

    2014-01-01

    We present studies of high-order harmonic generation (HHG) at laser intensities well above saturation. We use driving laser pulses which present a particular electron dynamics in the turn-on stage. Our results predict an increasing on the harmonic yield, after an initial dropping, when the laser intensity is increased. This fact contradicts the general belief of a progressive degradation of the harmonic emission at ultrahigh intensities. We have identified a particular set of trajectories which emerges in the turn-on stage of these singular laser pulses, responsible of the unexpected growth on the harmonic efficiency at this high intensity regime. Our study combines two complementary approaches: classical analysis and full quantum mechanical calculations resulting from the numerical integration of the 3-dimensional time-dependent Schr\\"odinger equation complemented with the time-frequency analysis.

  2. Echinococcus granulosus: protoscolicidal effect of high intensity focused ultrasound.

    Science.gov (United States)

    Zou, Xiaoyi; Wang, Junan; Zhao, Hailong; Zhang, Jing; Wu, Weihua; Ye, Bin

    2009-04-01

    High intensity focused ultrasound (HIFU) is a new non-invasive technique which can cause cell death and tissue necrosis by focusing high-energy ultrasonic waves on a single location. The aim of our work is to investigate the damaging effect of HIFU on Echinococcus granulosus protoscolices, as well as its inhibitory effect on growth of hydatid cysts derived from protoscolices. The damaging effect of HIFU on protoscolices was investigated by following parasite mortality after irradiation, while the inhibitory effect was investigated by infection experiments in vivo. The results demonstrated that HIFU was able to damage protoscolices and the protoscolicidal effect was dose-dependent and showed late-onset. The growth of protoscolices that survived the exposure to HIFU was obviously suppressed in vitro, and the mean weight of hydatid cysts resulting from such protoscolices in the experimental group was less than that in controls. Evidences including the protoscolicidal effect, fragmentized protoscolices and low post exposure temperatures, suggest that cavitation may contribute to the protoscolicidal effect of HIFU. In addition, the structure of the germinal membrane in cysts developing from the irradiated protoscolices was not as normal or intact as that from non-irradiated ones, and morphological changes related to degeneration were observed, suggesting that HIFU could prevent protoscolices from developing normal germinal membrane and consequently stop the proliferation of secondary hydatid cysts. HIFU demonstrated damaging effect on protoscolices, inhibited the growth of protoscolices in vitro and in vivo, and could be a possible therapeutic option for cystic echinococcosis.

  3. Interaction of High Intensity Electromagnetic Waves with Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    G. Shvets

    2008-10-03

    The focus of our work during the duration of this grant was on the following areas: (a) the fundamental plasma physics of intense laser-plasma interactions, including the nonlinear excitation of plasma waves for accelerator applications, as well as the recently discovered by us phenomenon of the relativistic bi-stability of relativistic plasma waves driven by a laser beatwave; (b) interaction of high power microwave beams with magnetized plasma, including some of the recently discovered by us phenomena such as the Undulator Induced Transparency (UIT) as well as the new approaches to dynamic manipulation of microwave pulses; (c) investigations of the multi-color laser pulse interactions in the plasma, including the recently discovered by us phenomenon of Electromagnetic Cascading (EC) and the effect of the EC of three-dimensional dynamics of laser pulses (enhanced/suppressed selffocusing etc.); (d) interaction of high-current electron beams with the ambient plasma in the context of Fast Ignitor (FI) physics, with the emphasis on the nonlinear dynamics of the Weibel instability and beam filamentation.

  4. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika;

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT...... high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance...... in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group....

  5. Influence of particle size and concentration on the diffuse backscattering of polarized light from tissue phantoms and biological cell suspensions

    Energy Technology Data Exchange (ETDEWEB)

    Hielscher, A.H.; Mourant, J.R.; Bigio, I.J. [Los Alamos National Laboratory, Bioscience and Biotechnology, CST-4, MS E535, Los Alamos, New Mexico 87545 (United States)

    1997-01-01

    We present experimental results that show the spatial variations of the diffuse-backscattered intensity when linearly polarized light is incident upon highly scattering media. Experiments on polystyrene-sphere and Intralipid suspensions demonstrate that the radial and azimuthal variations of the observed pattern depend on the concentration, and anisotropy factor {ital g} of the particles that constitute the scattering medium. Measurements performed on biological-cell suspensions show the potential of this method for cell characterization. {copyright} 1997 Optical Society of America

  6. Detection of Coaxial Backscattered Electrons in SEM

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    We present a coaxial detection of the backscattered electrons in SEM. The lens-aperture has been used to filter in energy and focus the backscattered electrons. This particular geometry allows us to eliminate the iow energy backscattered electrons and collect the backscattered electrons, which are backscattered close to the incident beam orientation. The main advantage of this geometry is adapted to topographic contrast attenuation and atomic number contrast enhancement. Thus this new SEM is very suitable to analyze the material composition.

  7. Creatine kinase response to high-intensity aerobic exercise in adult-onset muscular dystrophy

    DEFF Research Database (Denmark)

    Andersen, Søren P; Sveen, Marie-Louise; Hansen, Regitze S

    2013-01-01

    We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies.......We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies....

  8. Compliance with High-Intensity Radiated Fields Regulations - Emitter's Perspective

    Science.gov (United States)

    Statman, Joseph; Jamnejad, Vahraz; Nguyen, Lee

    2012-01-01

    NASA's Deep Space Network (DSN) uses high-power transmitters on its large antennas to communicate with spacecraft of NASA and its partner agencies. The prime reflectors of the DSN antennas are parabolic, at 34m and 70m in diameter. The DSN transmitters radiate Continuous Wave (CW) signals at 20 kW - 500 kW at X-band and S-band frequencies. The combination of antenna reflector size and high frequency results in a very narrow beam with extensive oscillating near-field pattern. Another unique feature of the DSN antennas is that they (and the radiated beam) move mostly at very slow sidereal rate, essentially identical in magnitude and at the opposite direction of Earth rotation.The DSN is in the process of revamping its documentation to provide analysis of the High Intensity Radiation Fields (HIRF) environment resulting from radio frequency radiation from DSN antennas for comparison to FAA regulations regarding certification of HIRF protection as outlined in the FAA regulations on HIRF protection for aircraft electrical and electronic systems (Title 14, Code of Federal Regulations (14 CFR) [section sign][section sign] 23.1308, 25.1317, 27.1317, and 29.1317).This paper presents work done at JPL, in consultation with the FAA. The work includes analysis of the radiated field structure created by the unique DSN emitters (combination of transmitters and antennas) and comparing it to the fields defined in the environments in the FAA regulations. The paper identifies areas that required special attention, including the implications of the very narrow beam of the DSN emitters and the sidereal rate motion. The paper derives the maximum emitter power allowed without mitigation and the mitigation zones, where required.Finally, the paper presents summary of the results of the analyses of the DSN emitters and the resulting DSN process documentation.

  9. Spectra of Particulate Backscattering in Natural Waters

    Science.gov (United States)

    Gordon, Howard, R.; Lewis, Marlon R.; McLean, Scott D.; Twardowski, Michael S.; Freeman, Scott A.; Voss, Kenneth J.; Boynton, Chris G.

    2009-01-01

    Hyperspectral profiles of downwelling irradiance and upwelling radiance in natural waters (oligotrophic and mesotrophic) are combined with inverse radiative transfer to obtain high resolution spectra of the absorption coefficient (a) and the backscattering coefficient (bb) of the water and its constituents. The absorption coefficient at the mesotrophic station clearly shows spectral absorption features attributable to several phytoplankton pigments (Chlorophyll a, b, c, and Carotenoids). The backscattering shows only weak spectral features and can be well represented by a power-law variation with wavelength (lambda): b(sub b) approx. Lambda(sup -n), where n is a constant between 0.4 and 1.0. However, the weak spectral features in b(sub b), suggest that it is depressed in spectral regions of strong particle absorption. The applicability of the present inverse radiative transfer algorithm, which omits the influence of Raman scattering, is limited to lambda < 490 nm in oligotrophic waters and lambda < 575 nm in mesotrophic waters.

  10. High-intensity interval training vs. moderate-intensity continuous training in the prevention/management of cardiovascular disease

    OpenAIRE

    S Hussain; Macaluso, A; Pearson, S.

    2016-01-01

    Moderate-intensity continuous training (MICT) has long been considered the most effective exercise treatment modality for the prevention and management of cardiovascular disease, but more recently high-intensity interval training (HIIT) has emerged into the clinical environment has been viewed as a potential alternative to MICT in accruing such benefits. HIIT was initially found to induce significant improvements in numerous physiological and health-related indices, to a similar if not superi...

  11. A review of adolescent high-intensity interval training.

    Science.gov (United States)

    Logan, Greig R M; Harris, Nigel; Duncan, Scott; Schofield, Grant

    2014-08-01

    Despite the promising evidence supporting positive effects of high-intensity interval training (HIIT) on the metabolic profile in adults, there is limited research targeting adolescents. Given the rising burden of chronic disease, it is essential to implement strategies to improve the cardiometabolic health in adolescence, as this is a key stage in the development of healthy lifestyle behaviours. This narrative review summarises evidence of the relative efficacy of HIIT regarding the metabolic health of adolescents. Methodological inconsistencies confound our ability to draw conclusions; however, there is meaningful evidence supporting HIIT as a potentially efficacious exercise modality for use in the adolescent cohort. Future research must examine the effects of various HIIT protocols to determine the optimum strategy to deliver cardiometabolic health benefits. Researchers should explicitly show between-group differences for HIIT intervention and steady-state exercise or control groups, as the magnitude of difference between HIIT and other exercise modalities is of key interest to public health. There is scope for research to examine the palatability of HIIT as an exercise modality for adolescents through investigating perceived enjoyment during and after HIIT, and consequent long-term exercise adherence.

  12. High intensity ultrasound modified ovalbumin: Structure, interface and gelation properties.

    Science.gov (United States)

    Xiong, Wenfei; Wang, Yuntao; Zhang, Chunlan; Wan, Jiawei; Shah, Bakht Ramin; Pei, Yaqiong; Zhou, Bin; Li, Jin; Li, Bin

    2016-07-01

    Influence of high intensity ultrasound (HIUS) on the structure and properties of ovalbumin (OVA) were investigated. It was found that the subunits and secondary structure of OVA did not change significantly with HIUS treatment from the electrophoretic patterns and circular dichroism (CD) spectrum. The amount of free sulfhydryl groups increased and intrinsic fluorescence spectra analysis indicated changes in the tertiary structure and partial unfold of OVA after sonication increased. Compared with the untreated OVA, HIUS treatment increased the emulsifying activity and foaming ability, and decreased interface tension (oil-water and air-water interface), which due to the increased surface hydrophobicity and decreased the surface net charge in OVA, while the emulsifying and foaming stability had no remarkable differences. The increased particle size may be attributed to formation of protein aggregates. Moreover, the gelation temperatures of HIUS-treated samples were higher than the untreated OVA according to the temperature sweep model rheology, and this effect was consistent with the increased in surface hydrophobicity for ultrasound treated OVA. These changes in functional properties of OVA would promote its application in food industry. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Treatment of glaucoma with high intensity focused ultrasound.

    Science.gov (United States)

    Aptel, Florent; Lafon, Cyril

    2015-05-01

    Glaucoma is a common disease mainly due to an increase in pressure inside the eye, leading to a progressive destruction of the optic nerve, potentially to blindness. Intraocular pressure (IOP) is the result of a balance between production of liquid that fills the eye--aqueous humour--and its resorption. All treatments for glaucoma aim to reduce IOP and can therefore have two mechanisms of action: reducing aqueous humour production by the partial destruction or medical inhibition of the ciliary body--the anatomical structure responsible for production of aqueous humour--or facilitating the evacuation of aqueous humour from the eye. Several physical methods can be used to destroy the ciliary body, e.g. laser, cryotherapy, microwave. All these methods have two major drawbacks: they are non-selective for the organ to be treated and they have an unpredictable dose–effect relationship. High intensity focused ultrasound (HIFU) can be used to coagulate the ciliary body and avoid these drawbacks. A commercially available device was marketed in the 1980s, but later abandoned, essentially for technical reasons. A smaller circular device using miniaturised transducers was recently developed and proposed for clinical practice. Experimental studies have shown selective coagulation necrosis of the treated ciliary body. The first three clinical trials in humans have shown that this device was well tolerated and allowed a significant, predictable and sustained reduction of IOP. The aim of this contribution is to present a summary of the work concerning the use of HIFU to treat glaucoma.

  14. Robotic Assisted Laparoscopic Prostatectomy after High Intensity Focused Ultrasound Failure

    Directory of Open Access Journals (Sweden)

    Leon Telis

    2017-01-01

    Full Text Available Background. Prostate cancer is the most common cancer diagnosed in men. As new focal therapies become more popular in treatment of prostate cancer, failure cases requiring salvage therapy with either surgical or other techniques are being reported. Objective. To report the options in treatment of prostate cancer after recurrence or failure of the primary treatment modality. Methods. We report a salvage robotic assisted laparoscopic radical prostatectomy (RALP for prostate cancer recurrence following high intensity focused ultrasound treatment (HIFU in the United States. Results. A 67-year-old man who underwent HIFU treatment for prostate adenocarcinoma 2 years prior was presented with a rising prostate specific antigen of 6.1 ng/mL to our clinic. A biopsy proven recurrent disease in the area of previous treatment documented the failure of treatment. The patient elected to undergo a salvage RALP. The operation time was 159 minutes. The patient was discharged from the hospital on postoperative day 1 with no complications. The catheter was removed on post-op day 10. The patient reserved sexual function and urinary continence. The PSA levels on 6 months’ follow-up are undetectable. Conclusions. Salvage RALP is an effective and safe treatment choice for recurrent prostate adenocarcinoma following failed HIFU treatment if operated by an experienced surgeon.

  15. Inelastic scattering in condensed matter with high intensity Moessbauer radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yelon, W.B.; Schupp, G.

    1990-10-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS{sub 2}, which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support.

  16. Gamma scattering in condensed matter with high intensity Moessbauer radiation

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as a facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS{sub 2}, which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support.

  17. High intensity ultrasound transducer used in gene transfection

    Science.gov (United States)

    Morrison, Kyle P.; Keilman, George W.; Noble, Misty L.; Brayman, Andrew A.; Miao, Carol H.

    2012-11-01

    This paper describes a novel therapeutic high intensity non-focused ultrasound (HIU) transducer designed with uniform pressure distribution to aid in accelerated gene transfer in large animal liver tissues in vivo. The underlying HIU transducer was used to initiate homogeneous cavitation throughout the tissue while delivering up to 2.7 MPa at 1.1 MHz across its radiating surface. The HIU transducer was built into a 6 cm diameter x 1.3 cm tall housing ergonomically designed to avoid collateral damage to the surrounding anatomy during dynamic motion. The ultrasound (US) radiation was applied in a 'paintbrush-like' manner to the surface of the liver. The layers and geometry of the transducer were carefully selected to maximize the active diameter (5.74 cm), maximize the electrical to acoustic conversion efficiency (85%) to achieve 2.7 MPa of peak negative pressure, maximize the frequency operating band at the fundamental resonance to within a power transfer delta of 1 dB, and reduce the pressure delta to within 2 dB across the radiating surface. For maximum peak voltage into the transducer, a high performance piezoceramic was chosen and a DC bias circuit was built integral to the system. An apodized two element annular pattern was made from a single piezoceramic element, resulting in significant pressure uniformity enhancement. In addition to using apodization for pressure uniformity, a proprietary multi-layered structure was used to improve efficiency while sustaining an operating band from 900 kHz to 1.3 MHz. The resultant operating band allowed for dithering techniques using frequency modulation. The underlying HIU transducer for use in large animals enhances gene expression up to 6300-fold.

  18. HIGH-INTENSITY FOCUSED ULTRASOUND CASTRATION FOR BREAST CANCER PATIENTS

    Institute of Scientific and Technical Information of China (English)

    王书文; 和新盈; 石景森; 赵东利; 李明众; 王诚; 薛文华

    2003-01-01

    Objective: To evaluate the safety and efficacy of external high-intensity focused ultrasound(HIFU) castration for breast cancerous patients after mastectomy if they are at a high risk of recurrence. Methods: We recruited 52 consecutive patients with primary operable breast cancer who were treated with mastectomy with excision of regional lymph nodes. Patients were positive for ER and PR immuno- cytochemical staining, node-positive, un-menopause, over 40 years old and were divided into two groups randomly. For castration, 26 patients received one or two times of HIFU treatment within five days, and the other patients received radiotherapy with DT 18Gy/9 f/11days. During and after the treatment, local changes and systemic response of the patients were observed. Results: After 1 month treatment, levels of serum E1 and E2 were significantly decreased compared to before treatment in HIFU groups (P<0.01 and P<0.001). The same changes were occurred in radiotherapy(RT) groups (P<0.05 and P<0.01). The levels of serum E1 or E2 in RT groups were higher than in HIFU groups (P<0.05). The symptom distribution of 'climacteric syndrome' of HIFU groups were significantly different from RT groups (P<0.01). The follow-up time was 4 months. The incidence of amenorrhea was 100% in all patients. No serious complications were seen. The temperature, pulse, blood pressure, and respiratory rate of the patients were almost normal. Conclusion: We have shown that the use of HIFU in the castrating of patients with breast cancer is feasible, safe and effective. This technology may provide a rapid noninvasive alterative to conventional bilateral oophorectomy or RT castration.

  19. Ultrasonic backscatter from cancellous bone: the apparent backscatter transfer function.

    Science.gov (United States)

    Hoffmeister, Brent K; Mcpherson, Joseph A; Smathers, Morgan R; Spinolo, P Luke; Sellers, Mark E

    2015-12-01

    Ultrasonic backscatter techniques are being developed to detect changes in cancellous bone caused by osteoporosis. Many techniques are based on measurements of the apparent backscatter transfer function (ABTF), which represents the backscattered power from bone corrected for the frequency response of the measurement system. The ABTF is determined from a portion of the backscatter signal selected by an analysis gate of width τw delayed by an amount τd from the start of the signal. The goal of this study was to characterize the ABTF for a wide range of gate delays (1 μs ≤ τd ≤ 6 μs) and gate widths (1 μs ≤ τw ≤ 6 μs). Measurements were performed on 29 specimens of human cancellous bone in the frequency range 1.5 to 6.0 MHz using a broadband 5-MHz transducer. The ABTF was found to be an approximately linear function of frequency for most choices of τd and τw. Changes in τd and τw caused the frequency-averaged ABTF [quantified by apparent integrated backscatter (AIB)] and the frequency dependence of the ABTF [quantified by frequency slope of apparent backscatter (FSAB)] to change by as much as 24.6 dB and 6.7 dB/MHz, respectively. τd strongly influenced the measured values of AIB and FSAB and the correlation of AIB with bone density (-0.95 ≤ R ≤ +0.68). The correlation of FSAB with bone density was influenced less strongly by τd (-0.97 ≤ R ≤ -0.87). τw had a weaker influence than τd on the measured values of AIB and FSAB and the correlation of these parameters with bone density.

  20. Detection of buried landmine with X-ray backscatter technique

    Energy Technology Data Exchange (ETDEWEB)

    Yuk, Sunwoo [Department of Electronics and Information Engineering, Korea University, Seoul (Korea, Republic of)]. E-mail: sunwoo@korea.ac.kr; Kim, Kwang Hyun [Chosun University, 375, Seosuk-Dong, Dong-Gu, Gwangju (Korea, Republic of); Yi, Yun [Department of Electronics and Information Engineering, Korea University, Seoul (Korea, Republic of)

    2006-11-30

    We describe a continuously operating scanning X-ray imaging system developed for landmine detection based on a backscatter X-ray principle, thus detection is done from the same side as the source. The source operates at 120 kV p and 3 mA. To study the physics of Compton X-ray backscattering, the photon transport factor, backscatter factor (BSF) and backscatter probability (BSP) were simulated using Monte-Carlo calculations using the generalized particle transport program MCNP. Based on the Monte-Carlo analyses results, a mine detecting system has been designed. It potentially has a low false alarm rate and a high detection probability, and a direct imaging facility.

  1. Impact of carrier heating on backscattering in inversion layers

    Science.gov (United States)

    Clerc, R.; Palestri, P.; Selmi, L.; Ghibaudo, G.

    2011-11-01

    In this work, Monte Carlo simulations and analytical modeling are used to investigate quasi-ballistic transport in nanometric metal oxide semiconductor field effect transistors (MOSFETs). In particular, we examine how the thermal nature of the distribution functions, which is implicitly assumed in the most common expression for the backscattering coefficient, leads to an underestimation of the backscattering coefficient in high field conditions and erroneous velocity distribution along the channel. An improved analytical model is proposed, which better captures the nonequilibrium nature of the distribution function and its impact on backscattering and by allowing velocity profiles to exceed the thermal limit. The improved model provides additional insights on the impact of several assumptions on backscattering and could serve as the basis for the development of physically based compact models of quasi-ballistic MOSFETs.

  2. 3D Backscatter Imaging System

    Science.gov (United States)

    Turner, D. Clark (Inventor); Whitaker, Ross (Inventor)

    2016-01-01

    Systems and methods for imaging an object using backscattered radiation are described. The imaging system comprises both a radiation source for irradiating an object that is rotationally movable about the object, and a detector for detecting backscattered radiation from the object that can be disposed on substantially the same side of the object as the source and which can be rotationally movable about the object. The detector can be separated into multiple detector segments with each segment having a single line of sight projection through the object and so detects radiation along that line of sight. Thus, each detector segment can isolate the desired component of the backscattered radiation. By moving independently of each other about the object, the source and detector can collect multiple images of the object at different angles of rotation and generate a three dimensional reconstruction of the object. Other embodiments are described.

  3. Advanced approaches to high intensity laser-driven ion acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Henig, Andreas

    2010-04-26

    Since the pioneering work that was carried out 10 years ago, the generation of highly energetic ion beams from laser-plasma interactions has been investigated in much detail in the regime of target normal sheath acceleration (TNSA). Creation of ion beams with small longitudinal and transverse emittance and energies extending up to tens of MeV fueled visions of compact, laser-driven ion sources for applications such as ion beam therapy of tumors or fast ignition inertial con finement fusion. However, new pathways are of crucial importance to push the current limits of laser-generated ion beams further towards parameters necessary for those applications. The presented PhD work was intended to develop and explore advanced approaches to high intensity laser-driven ion acceleration that reach beyond TNSA. In this spirit, ion acceleration from two novel target systems was investigated, namely mass-limited microspheres and nm-thin, free-standing diamond-like carbon (DLC) foils. Using such ultrathin foils, a new regime of ion acceleration was found where the laser transfers energy to all electrons located within the focal volume. While for TNSA the accelerating electric field is stationary and ion acceleration is spatially separated from laser absorption into electrons, now a localized longitudinal field enhancement is present that co-propagates with the ions as the accompanying laser pulse pushes the electrons forward. Unprecedented maximum ion energies were obtained, reaching beyond 0.5 GeV for carbon C{sup 6+} and thus exceeding previous TNSA results by about one order of magnitude. When changing the laser polarization to circular, electron heating and expansion were shown to be efficiently suppressed, resulting for the first time in a phase-stable acceleration that is dominated by the laser radiation pressure which led to the observation of a peaked C{sup 6+} spectrum. Compared to quasi-monoenergetic ion beam generation within the TNSA regime, a more than 40 times

  4. Comparison of the time behavior in the separation of light and heavy materials in X-ray backscattered method as a diagnostic tool in inspection

    Energy Technology Data Exchange (ETDEWEB)

    Faezeh, Rahmani, E-mail: FRahmani@kntu.ac.ir [Department of Physics, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Sepideh Sadat, Azimi [Radiation Application Department, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Esmaiel, Bayat; Vahid, Dost Mohammadi [Nuclear Science and Technology Research Institute (NSTR), Tehran (Iran, Islamic Republic of)

    2016-03-11

    X-ray backscattered method based on Compton backscattering is used in the inspection field. In contrast to transmission method, source and detectors are positioned on one side of the target, so in the situation that transmission inspection is difficult, X-ray backscattered method can be provided suitable data in the inspection field. Also, detection of hidden explosives and narcotic materials are very difficult or impossible in transmission methods. High intensity backscattered beam from light materials (low-Z), such as explosives and narcotics, in comparison to the heavy materials (high-Z), made this method as the strong technique in inspection. X-ray and gamma photons scattered by the light material (such as PE and PTFE) as well as heavy material (such as Fe and Cu) were studied using MCNPX2.6 Monte Carlo code. The results showed that rise time of pulse from light materials are slower than that of from heavy materials due to multi scattering of low energy photons in the light ones, so time expansion would occur in signals from light elements. If measurement is possible, the difference in time behavior can be used as a novel method in complementary diagnostic tool beside the use of pulse height in X-ray backscattered method.

  5. Effects of optical backscattering on silicon photonic hybrid laser performance

    Science.gov (United States)

    Pacradouni, V.; Klein, J.; Pond, J.

    2016-04-01

    We present numerical results on the effect of backscattering at the junctions of double bus ring resonators in a Vernier ring hybrid laser design. The structure is comprised off a pair of III-V gain media evanescently coupled to a silicon on insulator racetrack comprised of a pair of double bus ring resonators coupled together through straight and flared waveguide sections. We show how the small backscattering at the ring resonator junctions has the effect of splitting and shifting the resonances off the clockwise and counter clockwise propagating modes thereby modifying the feedback spectrum from the ideal case. We then simulate results such as light current (LI) curves, relative intensity noise (RIN) and laser spectrum, and compare the laser performance including backscattering effects with the ideal case.

  6. High-Intensity Training and Salivary Immunoglobulin A Responses in Professional Top-Level Soccer Players: Effect of Training Intensity.

    Science.gov (United States)

    Owen, Adam L; Wong, Del P; Dunlop, Gordon; Groussard, Carole; Kebsi, Wiem; Dellal, Alexandre; Morgans, Ryland; Zouhal, Hassane

    2016-09-01

    Owen, AL, Wong, DP, Dunlop, G, Groussard, C, Kebsi, W, Dellal, A, Morgans, R, and Zouhal, H. High-intensity training and salivary immunoglobulin A responses in professional top-level soccer players: Effect of training intensity. J Strength Cond Res 30(9): 2460-2469, 2016-This study aimed (a) to test the hypothesis that salivary immunoglobulin A (s-IgA) would vary with training intensity sessions (low-intensity [LI] vs. high-intensity sessions [HI]) during a traditional training program divided into 4 training periods and (b) to identify key variables (e.g., GPS data, rating of perceived exertion [RPE], and training duration), which could affect s-IgA. Saliva samples of 10 elite professional soccer players were collected (a) before the investigation started to establish the baseline level and (b) before and after each 4 training sessions (LI vs. HI). Training intensity was monitored as internal (through heart rate responses and RPE) and external (through GPS) loads. High-intensity sessions were associated with higher external load (GPS) and with higher RPE. Baseline and pretraining s-IgA did not differ between the 4 training sessions both for HI and LI. Post-training s-IgA were not different (in absolute value and in percentage of change) between HI and LI sessions at the first 3 periods. However, at the fourth period, s-IgA concentration for HI session was significantly lower (p ≤ 0.05) than the LI session. The percentage change between s-IgA post-training and s-IgA baseline concentrations differ significantly (p ≤ 0.05) between HI and LI training sessions. Significant correlations between s-IgA and training intensity were also noted. High-intensity soccer training sessions might cause a significant decrease in s-IgA values during the postexercise window as compared with LI sessions. This study encourages coaches to monitor s-IgA in routine, particularly during HI training periods, to take precautions to avoid upper respiratory tract infection in highly trained

  7. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT perfor...

  8. High-Intensity Femtosecond Laser Interaction with Rare Gas Clusters

    Institute of Scientific and Technical Information of China (English)

    林亚风; 钟钦; 曾淳; 陈哲

    2001-01-01

    With a 45 fs multiterawatt 790 nm laser system and jets of argon and krypton atomic clusters, a study of the interaction of fs intense laser pulses with large size rare gas dusters was conducted. The maximum laser intensity of about 7 × 1016 W/cm2 and dusters composed of thousands of atoms which were determined through Rayleigh scattering measurements were involved inthe experiments. On the one hand, the results indicate that the interaction is strongly cluster size dependent. The stronger the interaction, the larger the clusters are. On the other hand, a saturation followed by a drop of the energy of ions ejected from the interaction will occur when the laser intensity exceeds a definite value for clusters of a certain size.

  9. The High Luminosity Challenge: potential and limitations of High Intensity High Brightness in the LHC and its injectors

    CERN Document Server

    De Maria, R; Banfi, D; Barranco, J; Bartosik, H; Benedetto, E; Bruce, R; Brüning, O; Calaga, R; Cerutti, F; Damerau, H; Esposito, L; Fartoukh, S; Fitterer, M; Garoby, R; Gilardoni, S; Giovannozzi, M; Goddard, B; Gorini, B; Hanke, K; Iadarola, G; Lamont, M; Meddahi, M; Métral, E; Mikulec, B; Mounet, N; Papaphilippou, Y; Pieloni, T; Redaelli, S; Rossi, L; Rumolo, G; Shaposhnikova, E; Sterbini, G; Todesco, E; Tomás, R; Zimmermann, F; Valishev, A

    2014-01-01

    High-intensity and high-brightness beams are key ingredients to maximize the LHC integrated luminosity and to exploit its full potential. This contribution describes the optimization of beam and machine parameters to maximize the integrated luminosity as seen by the LHC experiments, by taking into account the expected intensity and brightness reach of LHC itself and its injector chain as well as the capabilities of the detectors for next run and foreseen upgrade scenarios.

  10. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul; Dudnikov, Vadim

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  11. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dudnikov, Vadim [Muons, Inc., Batavia, IL (United States)

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  12. Proton Acceleration Drived by High-intensity Ultraviolet Laser

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The generation of energetic protons from a solid thin-foil by the interactions of ultra-short and intense laser pulses is investigated in numerous experiments in the last decade. The energetic proton beams are promising candidates for proton fast ignitor (PFI)

  13. Overview of novel photovoltaic conversion techniques at high intensity levels

    Science.gov (United States)

    Stirn, R. J.

    1978-01-01

    The paper describes several photovoltaic devices currently under development that can operate under light intensities considerably higher than can silicon solar cells. The technologies discussed include GaAs heteroface solar cells, multi-color systems, thermophotovoltaics, and laser energy conversion. Array costs for the GaAs and multi-color elements are estimated.

  14. Experimental Research at the Intensity Frontier in High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Marshak, Marvin L. [Univ. of Minnesota, Minneapolis, MN (United States)

    2014-06-30

    This Final Report describes DOE-supported Intensity Frontier research by the University of Minnesota during the interval April 1, 2011 to March 31, 2014. Primary activities included the MINOS, NOvA and LBNE Experiments and Heavy Quark studies at BES III.

  15. Modelling the distribution of hard seabed using calibrated multibeam acoustic backscatter data in a tropical, macrotidal embayment: Darwin Harbour, Australia

    Science.gov (United States)

    Siwabessy, P. Justy W.; Tran, Maggie; Picard, Kim; Brooke, Brendan P.; Huang, Zhi; Smit, Neil; Williams, David K.; Nicholas, William A.; Nichol, Scott L.; Atkinson, Ian

    2017-05-01

    Spatial information on the distribution of seabed substrate types in high use coastal areas is essential to support their effective management and environmental monitoring. For Darwin Harbour, a rapidly developing port in northern Australia, the distribution of hard substrate is poorly documented but known to influence the location and composition of important benthic biological communities (corals, sponges). In this study, we use angular backscatter response curves to model the distribution of hard seabed in the subtidal areas of Darwin Harbour. The angular backscatter response curve data were extracted from multibeam sonar data and analysed against backscatter intensity for sites observed from seabed video to be representative of "hard" seabed. Data from these sites were consolidated into an "average curve", which became a reference curve that was in turn compared to all other angular backscatter response curves using the Kolmogorov-Smirnov goodness-of-fit. The output was used to generate interpolated spatial predictions of the probability of hard seabed (p-hard) and derived hard seabed parameters for the mapped area of Darwin Harbour. The results agree well with the ground truth data with an overall classification accuracy of 75% and an area under curve measure of 0.79, and with modelled bed shear stress for the Harbour. Limitations of this technique are discussed with attention to discrepancies between the video and acoustic results, such as in areas where sediment forms a veneer over hard substrate.

  16. Max Tech and Beyond: High-Intensity Discharge Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable

  17. Crack nucleation using combined crystal plasticity modelling, high-resolution digital image correlation and high-resolution electron backscatter diffraction in a superalloy containing non-metallic inclusions under fatigue.

    Science.gov (United States)

    Zhang, Tiantian; Jiang, Jun; Britton, Ben; Shollock, Barbara; Dunne, Fionn

    2016-05-01

    A crystal plasticity finite-element model, which explicitly and directly represents the complex microstructures of a non-metallic agglomerate inclusion within polycrystal nickel alloy, has been developed to study the mechanistic basis of fatigue crack nucleation. The methodology is to use the crystal plasticity model in conjunction with direct measurement at the microscale using high (angular) resolution-electron backscatter diffraction (HR-EBSD) and high (spatial) resolution-digital image correlation (HR-DIC) strain measurement techniques. Experimentally, this sample has been subjected to heat treatment leading to the establishment of residual (elastic) strains local to the agglomerate and subsequently loaded under conditions of low cyclic fatigue. The full thermal and mechanical loading history was reproduced within the model. HR-EBSD and HR-DIC elastic and total strain measurements demonstrate qualitative and quantitative agreement with crystal plasticity results. Crack nucleation by interfacial decohesion at the nickel matrix/agglomerate inclusion boundaries is observed experimentally, and systematic modelling studies enable the mechanistic basis of the nucleation to be established. A number of fatigue crack nucleation indicators are also assessed against the experimental results. Decohesion was found to be driven by interface tensile normal stress alone, and the interfacial strength was determined to be in the range of 1270-1480 MPa.

  18. High performance computation on beam dynamics problems in high intensity compact cyclotrons

    Institute of Scientific and Technical Information of China (English)

    ADELMANN; Andreas

    2011-01-01

    This paper presents the research progress in the beam dynamics problems for future high intensity compact cyclotrons by utilizing the state-of-the-art high performance computation technology. A "Start-to-Stop" model, which includes both the interaction of the internal particles of a single bunch and the mutual interaction of neighboring multiple bunches in the radial direction, is established for compact cyclotrons with multi-turn extraction. This model is then implemented in OPAL-CYCL, which is a 3D object-oriented parallel code for large scale particle simulations in cyclotrons. In addition, to meet the running requirement of parallel computation, we have constructed a small scale HPC cluster system and tested its performance. Finally, the high intensity beam dynamics problems in the 100 MeV compact cyclotron, which is being constructed at CIAE, are studied using this code and some conclusions are drawn.

  19. X-ray backscatter imaging

    Science.gov (United States)

    Dinca, Dan-Cristian; Schubert, Jeffrey R.; Callerame, J.

    2008-04-01

    In contrast to transmission X-ray imaging systems where inspected objects must pass between source and detector, Compton backscatter imaging allows both the illuminating source as well as the X-ray detector to be on the same side of the target object, enabling the inspection to occur rapidly and in a wide variety of space-constrained situations. A Compton backscatter image is similar to a photograph of the contents of a closed container, taken through the container walls, and highlights low atomic number materials such as explosives, drugs, and alcohol, which appear as especially bright objects by virtue of their scattering characteristics. Techniques for producing X-ray images based on Compton scattering will be discussed, along with examples of how these systems are used for both novel security applications and for the detection of contraband materials at ports and borders. Differences between transmission and backscatter images will also be highlighted. In addition, tradeoffs between Compton backscatter image quality and scan speed, effective penetration, and X-ray source specifications will be discussed.

  20. Fundamentals of Acoustic Backscatter Imagery

    Science.gov (United States)

    2011-09-20

    41 6.12 Geocoding ...47 7.6 Errors in Geocoding .............................................................................................................. 47...h = z - R cos6 (39a) and x = rt sin6. (39b) 6.12 Geocoding Acoustic backscatter imagery data are collected by recording the across-track signals

  1. Max Tech and Beyond: High-Intensity Discharge Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable

  2. Nodule bottom backscattering study using multibeam echosounder

    Digital Repository Service at National Institute of Oceanography (India)

    Chakraborty, B.; Raju, Y.S.N.; Nair, R.R.

    A study is carried out to observe the angular dependence of backscattering strength at nodule area where grab sample and photographic data is available. Theoretical study along with the experimentally observed data shows that the backscattering...

  3. Backscatter B [8101]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  4. Backscatter A [8101]--Offshore San Gregorio, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of SIM 3306 presents data for the acoustic-backscatter map (see sheet 3, SIM 3306) of the Offshore of San Gregorio map area, California. Backscatter data...

  5. BackscatterA [8101]--Offshore Pacifica, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of Offshore of Pacifica map area, California. Backscatter data are provided as two separate grids...

  6. Backscatter C [7125]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  7. BackscatterB [7125]--Offshore Pacifica, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of Offshore of Pacifica map area, California. Backscatter data are provided as two separate grids...

  8. Backscatter A [8101]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  9. Backscatter D [Snippets]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  10. BackscatterA [8101]--Offshore Pacifica, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of Offshore of Pacifica map area, California. Backscatter data are provided as two separate grids...

  11. BackscatterB [7125]--Offshore Pacifica, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of Offshore of Pacifica map area, California. Backscatter data are provided as two separate grids...

  12. Backscatter [5m]--Offshore Monterey, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of Offshore of Monterey map area, California. Backscatter data are provided as separate grids...

  13. Backscatter E [Swath]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  14. Backscatter B [7125]--Offshore San Gregorio, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of SIM 3306 presents data for the acoustic-backscatter map (see sheet 3, SIM 3306) of the Offshore of San Gregorio map area, California. Backscatter data...

  15. Backscatter [SWATH]--Offshore Santa Cruz, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of Offshore of Santa Cruz map area, California. Backscatter data are provided as three separate...

  16. Backscatter [SWATH]--Offshore Santa Cruz, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of Offshore of Santa Cruz map area, California. Backscatter data are provided as three separate...

  17. Backscatter [5m]--Offshore Monterey, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of Offshore of Monterey map area, California. Backscatter data are provided as separate grids...

  18. Backscatter C [7125]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  19. Backscatter A [8101]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  20. Backscatter B [8101]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  1. Backscatter D [Snippets]--Offshore Bolinas, California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This part of DS 781 presents data for the acoustic-backscatter map of the Offshore of Bolinas map area, California. Backscatter data are provided as separate grids...

  2. Understanding laser-solid interactions at ultra-high intensities

    Science.gov (United States)

    Murphy, C. D.; Gray, R. J.; Carroll, D. C.; MacLellan, D. A.; Powell, H.; Scott, G. G.; Ridgers, C. P.; Brady, C. S.; Neely, D.; Green, J. S.; Booth, N.; McKenna, P.

    2012-10-01

    The interaction of matter with lasers is a subject which has progressed rapidly over the last two decades as higher intensity lasers have opened the door to nonlinear and then relativistic interactions such that applications in ion acceleration and x-ray backlighting sources have become a clear possibility. Until recently, lasers capable of reaching the highest intensities (˜10^21 Wcm-2) have been glass-based systems with a low shot rate making detailed studies prohibitively time consuming. The development of petawatt-class Ti:Sapphire lasers such as Astra Gemini at STFC - Rutherford Appleton Laboratory, has made the systematic studies required to understand such interaction physics feasible. One such experiment on the Astra Gemini laser will be presented. The photon and particle diagnostics used will be explained and their results presented.

  3. Ionization Chambers for Monitoring in High-Intensity Neutrino Beams

    CERN Document Server

    McDonald, J; Velissaris, C; Erwin, A R; Ping, H; Viren, B M; Diwan, M V

    2002-01-01

    Radiation-hard ionization chambers were tested using an intense electron beam from the accelerator test facility (ATF) at the Brookhaven National Laboratory (BNL). The detectors were designed to be used as the basic element for monitoring muons in the Main Injector Neutrino beamline (NuMI) at the Fermi National Accelerator Laboratory (FNAL). Measurements of linearity of response, voltage dependence, and the onset of ionization saturation as a function of gap voltage were performed.

  4. Southern high-latitude Digisonde observations of ionosphere E-region Bragg scatter during intense lacuna conditions

    Directory of Open Access Journals (Sweden)

    D. P. Monselesan

    2004-09-01

    Full Text Available During summer months at solar cycle minimum, F-region lacuna and slant-Es conditions (SEC are common features of daytime ionograms recorded around local magnetic noon at Casey, Antarctica. Digisonde measurements of drift velocity height profiles show that the occurrence of lacuna prevents the determination of F-region drift velocities and also affects E-region drift velocity measurements. Unique E-region spectral features revealed as intervals of Bragg scatter superimposed on typical background E-region reflection were observed in Digisonde Doppler spectra during intense lacuna conditions. Daytime E-region Doppler spectra recorded at carrier frequencies from 1.5 to 2.7MHz, below the E-region critical frequency foE, have two side-peaks corresponding to Bragg scatter at approximately ±1-2Hz symmetrically located on each side of a central-peak corresponding to near-zenith total reflections. Angle-of-arrival information and ray-tracing simulations show that echo returns are coming from oblique directions most likely resulting from direct backscatter from just below the total reflection height for each sounding frequency. The Bragg backscatter events are shown to manifest during polar lacuna conditions, and to affect the determination of E-region background drift velocities, and as such must be considered when using standard Doppler-sorted interferometry (DSI techniques to estimate ionospheric drift velocities. Given the Doppler and spatial separation of the echoes determined from high-resolution Doppler measurements, we are able to estimate the Bragg scatter phase velocity independently from the bulk E-region motion. The phase velocity coincides with the ExB direction derived from in situ fluxgate magnetometer records. When ionospheric refraction is considered, the phase velocity amplitudes deduced from DSI are comparable to the ion-acoustic speed expected in the E-region. We briefly consider the plausibility that these

  5. Development of a cryogenic hydrogen microjet for high-intensity, high-repetition rate experiments

    Science.gov (United States)

    Kim, J. B.; Göde, S.; Glenzer, S. H.

    2016-11-01

    The advent of high-intensity, high-repetition-rate lasers has led to the need for replenishing targets of interest for high energy density sciences. We describe the design and characterization of a cryogenic microjet source, which can deliver a continuous stream of liquid hydrogen with a diameter of a few microns. The jet has been imaged at 1 μm resolution by shadowgraphy with a short pulse laser. The pointing stability has been measured at well below a mrad, for a stable free-standing filament of solid-density hydrogen.

  6. Application of the speed-duration relationship to normalize the intensity of high-intensity interval training.

    Directory of Open Access Journals (Sweden)

    Carrie Ferguson

    Full Text Available The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8 then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4, 6 min (WR6 and 8 min (WR8, interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min. A sub-group of subjects (n = 6 also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (P0.050. However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m, 3 (136.9±38.9 m, and 4 (136.7±39.3 m, compared with bout 1 (264.9±58.7 m; P>0.050. These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols.

  7. Application of the speed-duration relationship to normalize the intensity of high-intensity interval training.

    Science.gov (United States)

    Ferguson, Carrie; Wilson, John; Birch, Karen M; Kemi, Ole J

    2013-01-01

    The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM) relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT) has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8) then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4), 6 min (WR6) and 8 min (WR8), interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT) on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min). A sub-group of subjects (n = 6) also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT) to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (PHIIT, there was no difference in tLIM of each of the 4 bouts (Bout 1: 229±27 s; Bout 2: 262±37 s; Bout 3: 235±49 s; Bout 4: 235±53 s; P>0.050). However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m), 3 (136.9±38.9 m), and 4 (136.7±39.3 m), compared with bout 1 (264.9±58.7 m; P>0.050). These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols.

  8. Causative factors of high intensity areas identified by MRI in the pontine base

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Masaki; Takahashi, Akira [Nagoya Univ. (Japan). Faculty of Medicine; Arahata, Yutaka; Motegi, Yoshimasa

    1994-08-01

    High intensity areas in the pontine base were found more frequently in patients of group A who had multiple supratentorial high intensity areas smaller than 15 mm in size and of group B whose vertebral arteries were asymmetric on MR angiography, as compared to those who had none of the above findings of MRI and MR angiography. The high intensity areas of group A were often found bilaterally in the upper pons and those of group B were present unilaterally in the lower pons. Pontine high intensity areas were found frequently on the same side as the smaller vertebral artery in group B. Periventricular hyperintensity was more severe in group A than than in group B. These results suggest that high intensity lesions in the pontine base may conform with the following conditions: (1) multiple small high intensity areas in the supratentorium due to diffuse arteriosclerosis, and (2) asymmetry of the vertebral arteries inducing hemodynamic disorders. (author).

  9. Beam dynamics of mixed high intensity highly charged ion Beams in the Q/A selector

    Science.gov (United States)

    Zhang, X. H.; Yuan, Y. J.; Yin, X. J.; Qian, C.; Sun, L. T.; Du, H.; Li, Z. S.; Qiao, J.; Wang, K. D.; Zhao, H. W.; Xia, J. W.

    2017-06-01

    Electron cyclotron resonance (ECR) ion sources are widely used in heavy ion accelerators for their advantages in producing high quality intense beams of highly charged ions. However, it exists challenges in the design of the Q/A selection systems for mixed high intensity ion beams to reach sufficient Q/A resolution while controlling the beam emittance growth. Moreover, as the emittance of beam from ECR ion sources is coupled, the matching of phase space to post accelerator, for a wide range of ion beam species with different intensities, should be carefully studied. In this paper, the simulation and experimental results of the Q/A selection system at the LECR4 platform are shown. The formation of hollow cross section heavy ion beam at the end of the Q/A selector is revealed. A reasonable interpretation has been proposed, a modified design of the Q/A selection system has been committed for HIRFL-SSC linac injector. The features of the new design including beam simulations and experiment results are also presented.

  10. The effect of progressive high-intensity inspiratory muscle training and fixed high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients.

    Science.gov (United States)

    Jung, Ju-Hyeon; Kim, Nan-Soo

    2015-10-01

    [Purpose] This study investigated the effects of progressive load and fixed load high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients. [Subjects] Twenty-one stroke patients were assigned to one of three groups: progressive load high-intensity inspiratory muscle training (n = 8), fixed load high-intensity inspiratory muscle training (n = 6), and controls (n = 7). [Methods] The progressive load and fixed load high-intensity inspiratory muscle training participants undertook an exercise program for 20 minutes, three times weekly, for 6 weeks. After each session, diaphragm thickness was measured using ultrasonography. The diaphragm asymmetry ratio and diaphragm thickening ratio were standardized using a formula. [Results] After intervention, the diaphragm asymmetry ratio significantly differed among the three groups, and the diaphragm asymmetry ratio significantly increased in the control group. A significant increase was identified in the diaphragm thickening ratio within the progressive load and fixed load high-intensity inspiratory muscle training groups. [Conclusion] Progressive load and fixed load high-intensity inspiratory muscle training decreased the asymmetry of diaphragm thickness in stroke patients; this effect, in turn, increased the diaphragm thickening ratio in stroke patients. The two interventions examined here should be selectively applied to individuals in the clinical field.

  11. Intensity ratio measurements for density sensitive lines of highly charged Fe ions

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Safdar, E-mail: safdaruetian@gmail.com; Shimizu, Erina [Institute for Laser Science, The University of Electro-Communications (Japan); Sakaue, Hiroyuki A.; Kato, Daiji; Murakami, Izumi [National Institute for Fusion Science (Japan); Yamamoto, Norimasa [Chubu University (Japan); Hara, Hirohisa; Watanabe, Tetsuya [The Graduate University of Advanced Studies (SOKENDAI) (Japan); Nakamura, Nobuyuki, E-mail: n-nakamu@ils.uec.ac.jp [Institute for Laser Science, The University of Electro-Communications (Japan)

    2015-11-15

    Intensity ratio of density sensitive emission lines emitted from Fe ions in the extreme ultraviolet region is important for astrophysics applications. We report high-resolution intensity ratio measurements for Fe ions performed at Tokyo EBIT laboratory by employing a flat-field grazing incidence spectrometer. The experimental intensity ratios of Fe X and Fe XII are plotted as a function of electron density for different electron beam currents. The experimental results are compared with the predicted intensity ratios from the model calculations.

  12. Intensity dependence in high-level facial expression adaptation aftereffect.

    Science.gov (United States)

    Hong, Sang Wook; Yoon, K Lira

    2017-06-14

    Perception of a facial expression can be altered or biased by a prolonged viewing of other facial expressions, known as the facial expression adaptation aftereffect (FEAA). Recent studies using antiexpressions have demonstrated a monotonic relation between the magnitude of the FEAA and adaptor extremity, suggesting that facial expressions are opponent coded and represented continuously from one expression to its antiexpression. However, it is unclear whether the opponent-coding scheme can account for the FEAA between two facial expressions. In the current study, we demonstrated that the magnitude of the FEAA between two facial expressions increased monotonically as a function of the intensity of adapting facial expressions, consistent with the predictions based on the opponent-coding model. Further, the monotonic increase in the FEAA occurred even when the intensity of an adapting face was too weak for its expression to be recognized. These results together suggest that multiple facial expressions are encoded and represented by balanced activity of neural populations tuned to different facial expressions.

  13. Enhancing gas-phase reaction in a plasma using high intensity and high power ultrasonic acoustic waves

    DEFF Research Database (Denmark)

    2010-01-01

    is absorbed into said plasma (104), and where a sound pressure level of said generated ultrasonic high intensity and high power acoustic waves (102) is at least substantially 140 dB and where an acoustic power of said generated ultrasonic high intensity and high power acoustic waves (102); is at least......This invention relates to enhancing a gas-phase reaction in a plasma comprising: creating plasma (104) by at least one plasma source (106), and wherein that the method further comprises: generating ultrasonic high intensity and high power acoustic waves (102) having a predetermined amount...... of acoustic energy by at least one ultrasonic high intensity and high power gas-jet acoustic wave generator (101), where said ultrasonic high intensity and high power acoustic waves are directed to propagate towards said plasma (104) so that at least a part of said predetermined amount of acoustic energy...

  14. Personalized metabolomics for predicting glucose tolerance changes in sedentary women after high-intensity interval training

    National Research Council Canada - National Science Library

    Kuehnbaum, Naomi L; Gillen, Jenna B; Gibala, Martin J; Britz-McKibbin, Philip

    2014-01-01

    High-intensity interval training (HIIT) offers a practical approach for enhancing cardiorespiratory fitness, however its role in improving glucose regulation among sedentary yet normoglycemic women remains unclear...

  15. Backscatter measurements for NIF ignition targets (invited).

    Science.gov (United States)

    Moody, J D; Datte, P; Krauter, K; Bond, E; Michel, P A; Glenzer, S H; Divol, L; Niemann, C; Suter, L; Meezan, N; MacGowan, B J; Hibbard, R; London, R; Kilkenny, J; Wallace, R; Kline, J L; Knittel, K; Frieders, G; Golick, B; Ross, G; Widmann, K; Jackson, J; Vernon, S; Clancy, T

    2010-10-01

    Backscattered light via laser-plasma instabilities has been measured in early NIF hohlraum experiments on two beam quads using a suite of detectors. A full aperture backscatter system and near backscatter imager (NBI) instrument separately measure the stimulated Brillouin and stimulated Raman scattered light. Both instruments work in conjunction to determine the total backscattered power to an accuracy of ∼15%. In order to achieve the power accuracy we have added time-resolution to the NBI for the first time. This capability provides a temporally resolved spatial image of the backscatter which can be viewed as a movie.

  16. Towards phasing using high X-ray intensity

    Directory of Open Access Journals (Sweden)

    Lorenzo Galli

    2015-11-01

    Full Text Available X-ray free-electron lasers (XFELs show great promise for macromolecular structure determination from sub-micrometre-sized crystals, using the emerging method of serial femtosecond crystallography. The extreme brightness of the XFEL radiation can multiply ionize most, if not all, atoms in a protein, causing their scattering factors to change during the pulse, with a preferential `bleaching' of heavy atoms. This paper investigates the effects of electronic damage on experimental data collected from a Gd derivative of lysozyme microcrystals at different X-ray intensities, and the degree of ionization of Gd atoms is quantified from phased difference Fourier maps. A pattern sorting scheme is proposed to maximize the ionization contrast and the way in which the local electronic damage can be used for a new experimental phasing method is discussed.

  17. The risk of retina damage from high intensity light sources.

    Science.gov (United States)

    Pollak, V A; Romanchuk, K G

    1980-05-01

    The risk of thermal damage to the retina of the eye by exposure to excessive light intensities from continuous and pulsed man-made sources is discussed. The probability of injury increases, the larger the radiant power absorbed by the retina and the smaller the size of the retinal image of the source. A mehtod of estimating the temperature increase of the immediately affected area of the retina is presented. The time constants involved are also briefly considered. Using numerical values from literature for the relevant parameters of the eye, threshold values for a variety of conditions can be established. Below these values little risk of retina damage should exist. The degree of hazard when these values are exceeded depends upon the circumstances. A case study of a welding accident showed good agreement between the conclusions of the theoretical analysis and clinical findings.

  18. Transverse feedback: high intensity operation, AGC, IGC, lessons for 2012

    CERN Document Server

    Höfle, W

    2012-01-01

    The transverse damper system (ADT) plays an important role in the preservation of the beam transverse emittance and for damping of oscillations driven by the coupled bunch instability. An overview of the ADT system will be presented with an emphasis on the important feedback loop parameters as they change from injection through the ramp into collision. The dedicated setting - up procedure required for the different bunch intensities and bunch spacings will be explained. During the 2011 run the injection and abort gap cleaning became operational at injection energy. Preparations for cleaning at 3.5 TeV as well as batch selective transverse blow - up were completed and preliminarily tested. Plans for 2012 include study and potential improvement of the system impulse response to improve the 'selectivity' of the cleaning and blow - up facility. The ADT also provides bunch - by - bunch observation, which was extensively used during the run and MDs, and will be further upgraded during the next year.

  19. Hybrid Broadband Ground-Motion Simulations: Combining Long-Period Deterministic Synthetics with High-Frequency Multiple S-to-S Backscattering

    KAUST Repository

    Mai, Paul Martin

    2010-09-20

    We present a new approach for computing broadband (0-10 Hz) synthetic seismograms by combining high-frequency (HF) scattering with low-frequency (LF) deterministic seismograms, considering finite-fault earthquake rupture models embedded in 3D earth structure. Site-specific HF-scattering Green\\'s functions for a heterogeneous medium with uniformly distributed random isotropic scatterers are convolved with a source-time function that characterizes the temporal evolution of the rupture process. These scatterograms are then reconciled with the LF-deterministic waveforms using a frequency-domain optimization to match both amplitude and phase spectra around the target intersection frequency. The scattering parameters of the medium, scattering attenuation ηs, intrinsic attenuation ηi, and site-kappa, as well as frequency-dependent attenuation, determine waveform and spectral character of the HF-synthetics and thus affect the hybrid broadband seismograms. Applying our methodology to the 1994 Northridge earthquake and validating against near-field recordings at 24 sites, we find that our technique provides realistic broadband waveforms and consistently reproduces LF ground-motion intensities for two independent source descriptions. The least biased results, compared to recorded strong-motion data, are obtained after applying a frequency-dependent site-amplification factor to the broadband simulations. This innovative hybrid ground-motion simulation approach, applicable to any arbitrarily complex earthquake source model, is well suited for seismic hazard analysis and ground-motion estimation.

  20. Hanle effect in coherent backscattering

    CERN Document Server

    Labeyrie, G; Müller, C A; Sigwarth, O; Delande, D; Kaiser, R

    2002-01-01

    We study the shape of the coherent backscattering (CBS) cone obtained when resonant light illuminates a thick cloud of laser-cooled rubidium atoms in presence of a homogenous magnetic field. We observe new magnetic field-dependent anisotropies in the CBS signal. We show that the observed behavior is due to the modification of the atomic radiation pattern by the magnetic field (Hanle effect in the excited state).

  1. Transmutation of nuclear wastes using photonuclear reactions triggered by Compton backscattering photons at the Shanghai laser electrongamma source

    Institute of Scientific and Technical Information of China (English)

    CHEN Jin-Gen; YUAN Ren-Yong; XU Jia-Qiang; YAN Zhe; FAN Gong-Tao; SHEN Wen-Qing; XU Wang; WANG Hong-Wei; GUO Wei; MA Yu-Gang; CAI Xiang-Zhou; LU Guang-Cheng; XU Yi; PAN Qiang-Yan

    2008-01-01

    Based on the facility of the Shanghai Laser Electron Gamma Source (SLEGS),the transmutation for nuclear wastes such as 137Cs and 129I is investigated.It is found that nuclear waste can be transmuted efficiently via photonuclear reaction triggered by gamma photons generated from Compton backscattering between CO2 laser photons and 3.5 GeV electrons.The nuclear activities of 137Cs and 129I are evaluated and compared with the results of transmutation triggered by bremsstrahlung gamma photons driven by ultra intense laser.Due to the better character of gamma photon spectrum as well as the high brightness of gamma photons,the transmutation rate of Compton backscattering method is much higher than that of the bremsstrahlung method.

  2. High-intensity training reduces CD8+ T-cell redistribution in response to exercise

    NARCIS (Netherlands)

    Witard, O.C.; Turner, J.E.; Jackman, S.R.; Tipton, K.D.; Jeukendrup, A.E.; Kies, A.K.; Bosch, J.A.

    2012-01-01

    Purpose: We examined whether exercise-induced lymphocytosis and lymphocytopenia are impaired with high-intensity training. Methods: Eight trained cyclists (V·O2max = 64.2 ± 6.5 mL·kg-1·min-1) undertook 1 wk of normal-intensity training and a second week of high-intensity training. On day 7 of each w

  3. Portable fluorescence meter with reference backscattering channel

    Science.gov (United States)

    Kornilin, Dmitriy V.; Grishanov, Vladimir N.; Zakharov, Valery P.; Burkov, Dmitriy S.

    2016-09-01

    Methods based on fluorescence and backscattering are intensively used for determination of the advanced glycation end products (AGE) concentration in the biological tissues. There are strong correlation between the AGE concentration and the severity of such diseases like diabetes, coronary heart disease and renal failure. This fact can be used for diagnostic purposes in medical applications. Only few investigations in this area can be useful for development of portable and affordable in vivo AGE meter because the most of them are oriented on using spectrometers. In this study we describe the design and the results of tests on volunteers of portable fluorescence meter based on two photodiodes. One channel of such fluorimeter is used for measurement of the autofluorescence (AF) intensity, another one - for the intensity of elastically scattered radiation, which can be used as a reference. This reference channel is proposed for normalization of the skin autofluorescence signal to the human skin photo type. The fluorimeter, that was developed is relatively compact and does not contain any expensive optical and electronic components. The experimental results prove that proposed tool can be used for the AGE estimation in human skin.

  4. Moderate intensity, but not high intensity, treadmill exercise training alters power output properties in myocardium from aged rats.

    Science.gov (United States)

    Chung, Eunhee; Diffee, Gary M

    2012-11-01

    Aging is characterized by a progressive decline in cardiac function, but endurance exercise training has been shown to retard a number of deleterious effects of aging. However, underlying mechanisms by which exercise training improves age-related decrements in myocardial contractile function are not well understood. The purpose of this study was to determine the effects of exercise training on power output properties in permeablized (skinned) myocytes of old rats. Thirty-month-old rats were divided into sedentary control (C) and groups undergoing 11 weeks of treadmill exercise training at moderate intensity (MI) and at high intensity (HI). Peak power output normalized to maximal force was significantly increased in MI but not in HI compared to C with significant increases in atrial myosin light chain 1 in ventricle. These results suggest that MI exercise training is beneficial as a significant increase was seen in the ability of the myocardium to do work, but this effect was not seen with HI training.

  5. Metabolic responses to high protein diet in Korean elite bodybuilders with high-intensity resistance exercise

    Directory of Open Access Journals (Sweden)

    Choue Ryowon

    2011-07-01

    Full Text Available Abstract Background High protein diet has been known to cause metabolic acidosis, which is manifested by increased urinary excretion of nitrogen and calcium. Bodybuilders habitually consumed excessive dietary protein over the amounts recommended for them to promote muscle mass accretion. This study investigated the metabolic response to high protein consumption in the elite bodybuilders. Methods Eight elite Korean bodybuilders within the age from 18 to 25, mean age 21.5 ± 2.6. For data collection, anthropometry, blood and urinary analysis, and dietary assessment were conducted. Results They consumed large amounts of protein (4.3 ± 1.2 g/kg BW/day and calories (5,621.7 ± 1,354.7 kcal/day, as well as more than the recommended amounts of vitamins and minerals, including potassium and calcium. Serum creatinine (1.3 ± 0.1 mg/dl and potassium (5.9 ± 0.8 mmol/L, and urinary urea nitrogen (24.7 ± 9.5 mg/dl and creatinine (2.3 ± 0.7 mg/dl were observed to be higher than the normal reference ranges. Urinary calcium (0.3 ± 0.1 mg/dl, and phosphorus (1.3 ± 0.4 mg/dl were on the border of upper limit of the reference range and the urine pH was in normal range. Conclusions Increased urinary excretion of urea nitrogen and creatinine might be due to the high rates of protein metabolism that follow high protein intake and muscle turnover. The obvious evidence of metabolic acidosis in response to high protein diet in the subjects with high potassium intake and intensive resistance exercise were not shown in this study results. However, this study implied that resistance exercise with adequate mineral supplementation, such as potassium and calcium, could reduce or offset the negative effects of protein-generated metabolic changes. This study provides preliminary information of metabolic response to high protein intake in bodybuilders who engaged in high-intensity resistance exercise. Further studies will be needed to determine the effects of the intensity

  6. Observation of transverse coherent backscattering in disordered photonic structures

    CERN Document Server

    Brake, Sebastian; Leykam, Daniel; Desyatnikov, Anton; Denz, Cornelia

    2015-01-01

    We report on the experimental observation of weak localization in an optically induced disordered (2+1)-dimensional photonic structure. Our flexible method of optical induction is applied with a nondiffracting random intensity distribution. We focus on the analysis of a statistical output spectrum for many probe events with variance of the incoming beam's transverse spatial frequency. For particular spatial frequencies we find considerable signatures of transverse coherent backscattering.

  7. [Reflected high-intensity motion signals as markers of left ventricular diastolic dysfunction].

    Science.gov (United States)

    Makarenko, E S

    2013-01-01

    Reflected high-intensity signals of left ventricular motion can be used for assessment of diastolic function of left ventricle. There are many correlations between reflected high-intensity signals, transmitral flow, and tissue Doppler imaging parameters. Diagnostic criteria of LV diastolic dysfunction based on measurement of LV motion are suggested.

  8. The influence of basketball dribbling on repeated high-intensity intermittent runs

    Directory of Open Access Journals (Sweden)

    Zhaowei Kong

    2015-12-01

    Conclusion: The results suggest that the Yo-Yo IE2 test could reflect the repeatability of high-intensity intermittent basketball dribbling performance, while dribbling skills may have different influences on high-intensity intermittent exercise capacity in adolescent players at different ages.

  9. Refinement of Eutectic Silicon Phase of Aluminum A356 Alloy Using High-Intensity Ultrasonic Vibration

    Energy Technology Data Exchange (ETDEWEB)

    Jian, Xiaogang [ORNL; Han, Qingyou [ORNL

    2006-01-01

    The eutectic silicon in A356 alloy can be refined and modified using either chemical, quench, or superheating modification. We observed, for the first time, that the eutectic silicon can also be significantly refined using high-intensity ultrasonic vibration. Rosette-like eutectic silicon is formed during solidification of specimen treated with high-intensity ultrasonic vibration.

  10. The study towards high intensity high charge state laser ion sources.

    Science.gov (United States)

    Zhao, H Y; Jin, Q Y; Sha, S; Zhang, J J; Li, Z M; Liu, W; Sun, L T; Zhang, X Z; Zhao, H W

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  11. The study towards high intensity high charge state laser ion sources

    Science.gov (United States)

    Zhao, H. Y.; Jin, Q. Y.; Sha, S.; Zhang, J. J.; Li, Z. M.; Liu, W.; Sun, L. T.; Zhang, X. Z.; Zhao, H. W.

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  12. Brillouin backscattering from a double-pulse CO/sub 2/ laser incident on planar targets

    Energy Technology Data Exchange (ETDEWEB)

    Decoste, R.; Lavigne, P.; Pepin, H.; Mitchel, G.R.; Kieffer, J.

    1982-05-01

    The Brillouin backscattering instability is studied for a range of preformed plasma conditions and using a CO/sub 2/ laser in the 10/sup 12/--10/sup 13/ W/cm/sup 2/ regime. A short prepulse is incident on a planar target ahead of the main-pulse to produce the preformed plasma. The instability appears in a short burst of back-reflected light. Saturation of the backscatter level is observed for an individual increase of the prepulse energy, main-pulse intensity, and prepulse-to-main-pulse delay. Ion Landau damping is strong and average back-reflected intensities are limited to less than 30% of incident. Backscattered light spectra suggest that the critical surface is involved in the backscatter process when the laser beam is at best focus onto the target surface. Otherwise, the spectral signature is similar to those obtained from underdense plasmas.

  13. COLLIMATORS AND MATERIALS FOR HIGH INTENSITY HEAVY ION SYNCHROTRONS

    CERN Document Server

    Stadlmann, J; Kollmus, H; Spiller, P; Strasik, I; Tahir, N A; Tomut, M; Trautmann, C

    2012-01-01

    The operation of high power high brightness accelerators requires huge efforts for beam cleaning and machine protection. Within the WP 8 (ColMat) of the EU research framework EuCARD[1] we investigate new materials and methods for beam collimation and machine protection. We present an overview of these activities at the GSI Helmholtzzentrum f¨ur Schwerionenforschung, Darmstadt. Simulations of accidental beam losses in LHC and SIS100 have been performed. Scenarios for halo collimation of heavy ions and protons in SIS100 routine operation have been investigated. A prototype of a cryogenic collimator for charge exchange losses during intermediate charge state heavy ion operation in SIS100 has been build and tested with beam. Several candidates of advanced composite materials for collimation system upgrades of present and future high power accelerators have been irradiated and their properties are being characterized. Most deliverables and milestones of the R&D programme were already reached before the end of...

  14. Extremely short duration high intensity interval training substantially improves insulin action in young healthy males

    DEFF Research Database (Denmark)

    Babraj, John A; Vollaard, Niels B J; Keast, Cameron

    2009-01-01

    BACKGROUND: Traditional high volume aerobic exercise training reduces cardiovascular and metabolic disease risk but involves a substantial time commitment. Extremely low volume high-intensity interval training (HIT) has recently been demonstrated to produce improvements to aerobic function, but i...

  15. Real-time monitoring of high-intensity focused ultrasound thermal therapy using the manifold learning method.

    Science.gov (United States)

    Rangraz, Parisa; Behnam, Hamid; Sobhebidari, Pooya; Tavakkoli, Jahan

    2014-12-01

    High-intensity focused ultrasound (HIFU) induces thermal lesions by increasing the tissue temperature in a tight focal region. The main ultrasound imaging techniques currently used to monitor HIFU treatment are standard pulse-echo B-mode ultrasound imaging, ultrasound temperature estimation and elastography-based methods. The present study was carried out on ex vivo animal tissue samples, in which backscattered radiofrequency (RF) signals were acquired in real time at time instances before, during and after HIFU treatment. The manifold learning algorithm, a non-linear dimensionality reduction method, was applied to RF signals whichconstruct B-mode images to detect the HIFU-induced changes among the image frames obtained during HIFU treatment. In this approach, the embedded non-linear information in the region of interest of sequential images is represented in a 2-D manifold with the Isomap algorithm, and each image is depicted as a point on the reconstructed manifold. Four distinct regions are chosen in the manifold corresponding to the four phases of HIFU treatment (before HIFU treatment, during HIFU treatment, immediately after HIFU treatment and 10-min after HIFU treatment). It was found that disorganization of the points is achieved by increasing the acoustic power, and if the thermal lesion has been formed, the regions of points related to pre- and post-HIFU significantly differ. Moreover, the manifold embedding was repeated on 2-D moving windows in RF data envelopes related to pre- and post-HIFU exposure data frames. It was concluded that if mean values of the points related to pre- and post-exposure frames in the reconstructed manifold are estimated, and if the Euclidean distance between these two mean values is calculated and the sliding window is moved and this procedure is repeated for the whole image, a new image based on the Euclidean distance can be formed in which the HIFU thermal lesion is detectable.

  16. High intensity electromagnetic field gerenation using a transportable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank

    2008-01-01

    A reverberation chamber can create very high field strength with moderate input power. Existing chambers are making use of a paddle wheel to change the resonant modes in the chamber. A transportable reverberation chamber with vibrating walls will be presented. Inside this Vibrating Intrinsic Reverbe

  17. STATUS REPORT ON DEVELOPMENT OF A HIGH-SPEED HIGH-INTENSITY MOLECULAR BEAM

    Energy Technology Data Exchange (ETDEWEB)

    Knuth, Eldon L.

    1963-07-15

    Status of a high-speed high-intensity molecular beam under development is described. Bases for designs of the several components are presented. Using an arc-heated source and a hypersonic jet, molecular energies exceeding 1 ev and beam intensities of the order of 10/sup 16/ molecules/ cm/sup 2/ sec are anticipated. A two-disk beam chopper and speed selector provides a means for analyzing the speed distribution in the generated beam, for chopping the beam into bursts of nearly monoenergetic molecules suitable for scattering studies using the time-of-flight technique, and for modulating the beam in order to facilitate detection. A through-flow ionization detector possesses the versatility required for scattering studies using the time-of-flight technique. A sorption pump and a turbo pump serve as central components of alternative pumping systems for the collimating chamber. Using the arc-heated source, the converging nozzle, the conduction-radiation-cooled skimmer, the turbo pump (turning at 3400 rpm), the chopperselector (acting only as a chopper), and the detector, an arc-heated beam is generated and detected. (auth)

  18. Multi-beam backscatter image data processing techniques employed to EM 1002 system

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, W.A.; Chakraborty, B.

    algorithm applies to raw backscatter intensities during normalization process. More detail study of the software is demonstrated using a flow diagram flowed by the stage by stage discussion in subsequent sections (Figure 1). III. DATA EXTRACTION... contribution no.xxxx. - 9 - REFERENCES: [1] Hughes Clarke JE (1993) The potential for seabed classification using backscatter from shallow water multibeam sonars. Proc Inst Acoustics 15(part2):381–387. [2] Chakraborty B and Kodagali, V Baracho J...

  19. Intense high-quality medical proton beams via laser fields

    CERN Document Server

    Galow, Benjamin J; Keitel, Christoph H

    2010-01-01

    Simulations based on the coupled relativistic equations of motion show that protons stemming from laserplasma processes can be efficiently post-accelerated employing crossed pulsed laser beams focused to spot radii on the order of the laser wavelength. We demonstrate that the crossed beams produce quasi-monoenergetic accelerated protons with kinetic energies exceeding 200 MeV, small energy spreads of about 1% and high densities as required for hadron cancer therapy.

  20. High-intensity molecular harmonic generation without ionization

    Institute of Scientific and Technical Information of China (English)

    Wang Jun; Chen Gao; Guo Fu-Ming; Li Su-Yu; Chen Ji-Gen; Yang Yu-Jun

    2013-01-01

    We theoretically investigate high-order harmonic generation from H2+ in an infrared laser field.Our numerical simulations show that a highly efficient plateau structure exists in the molecular harmonic spectrum.Under the action of the infrared laser pulse,the bound electronic wave packet in a potential well has enough time to tunnel through the effective potential barrier,which is formed by the molecular potential and the infrared laser field,and then recombine with the neighboring nucleus emitting a harmonic photon.During the entire dynamic process,because the wave packet is mainly located in the effective potential,the diffusion effect is of no significance,and thus a highly efficient harmonic plateau can be achieved.Specifically,the cut-off frequency of the plateau is linearly scaled with the peak amplitude of the infrared laser electric field,which may open another route to examine the internuclear distance of the molecule.Furthermore,one may detect the molecular bond lengths using the harmonic plateau.

  1. Radar backscatter properties of milo and soybeans

    Science.gov (United States)

    Bush, T. F.; Ulaby, F. T.; Metzler, T.

    1975-01-01

    The radar backscatter from fields of milo and soybeans was measured with a ground based radar as a function of frequency (8-18 GHz), polarization (HH and VV) and angle of incidence (0 deg-70 deg) during the summer of 1974. Supporting ground truth was gathered contemporaneously with the backscatter data. At nadir sigma deg of milo correlated highly, r = 0.96, with soil moisture in the milo field at 8.6 GHz but decreased to a value of r = 0.78 at a frequency of 17.0 GHz. Correlation studies of the variations of sigma deg with soil moisture in the soybean fields were not possible due to a lack of a meaningful soil moisture dynamic range. At the larger angles of incidence, however, sigma deg of soybeans did appear to be dependent on precipitation. It is suggested this phenomenon was caused by the rain altering plant geometry. In general sigma deg of both milo and soybeans had a relatively small dynamic range at the higher angles of incidence and showed no significant dependence on the measured crop parameters.

  2. A Highly intense DC muon source, MuSIC and muon CLFV search

    Science.gov (United States)

    Hino, Y.; Kuno, Y.; Sato, A.; Sakamoto, H.; Matsumoto, Y.; Tran, N. H.; Hashim, I. H.; Fukuda, M.; Hayashida, Y.; Ogitsu, T.; Yamamoto, A.; Yoshida, M.

    2014-08-01

    MuSIC is a new muon facility, which provides the world's highest intense muon beam with continuous time structure at Research Center of Nuclear Physics (RCNP), Osaka University. It's intensity is designed to be 108 muons per second with only 0.4 kW proton beam. Such a high intense muon beam is very important for searches of rare decay processes, for example search for the muon to electron conversion.

  3. A Highly intense DC muon source, MuSIC and muon CLFV search

    Energy Technology Data Exchange (ETDEWEB)

    Hino, Y.; Kuno, Y.; Sato, A. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Sakamoto, H. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Research Center of Nuclear Physics, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Matsumoto, Y.; Tran, N.H.; Hashim, I.H. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Fukuda, M.; Hayashida, Y. [Research Center of Nuclear Physics, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Ogitsu, T.; Yamamoto, A.; Yoshida, M. [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2014-08-15

    MuSIC is a new muon facility, which provides the world's highest intense muon beam with continuous time structure at Research Center of Nuclear Physics (RCNP), Osaka University. It's intensity is designed to be 10{sup 8} muons per second with only 0.4 kW proton beam. Such a high intense muon beam is very important for searches of rare decay processes, for example search for the muon to electron conversion.

  4. Noninvasive measurement of local thermal diffusivity using backscattered ultrasound and focused ultrasound heating.

    Science.gov (United States)

    Anand, Ajay; Kaczkowski, Peter J

    2008-09-01

    Previously, noninvasive methods of estimating local tissue thermal and acoustic properties using backscattered ultrasound have been proposed in the literature. In this article, a noninvasive method of estimating local thermal diffusivity in situ during focused ultrasound heating using beamformed acoustic backscatter data and applying novel signal processing techniques is developed. A high intensity focused ultrasound (HIFU) transducer operating at subablative intensities is employed to create a brief local temperature rise of no more than 10 degrees C. Beamformed radio-frequency (RF) data are collected during heating and cooling using a clinical ultrasound scanner. Measurements of the time-varying "acoustic strain", that is, spatiotemporal variations in the RF echo shifts induced by the temperature related sound speed changes, are related to a solution of the heat transfer equation to estimate the thermal diffusivity in the heated zone. Numerical simulations and experiments performed in vitro in tissue mimicking phantoms and excised turkey breast muscle tissue demonstrate agreement between the ultrasound derived thermal diffusivity estimates and independent estimates made by a traditional hot-wire technique. The new noninvasive ultrasonic method has potential applications in thermal therapy planning and monitoring, physiological monitoring and as a means of noninvasive tissue characterization.

  5. High-intensity drying processes-impulse drying

    Energy Technology Data Exchange (ETDEWEB)

    Orloff, D.I.

    1991-06-01

    Impulse drying is an innovative process for drying paper that holds great promise for reducing the energy consumed during the manufacture of paper and similar web products. impulse drying occurs when a wet paper web passes through a press nip in which one of the rolls is heated to a high temperature. A steam layer adjacent to the heated surface grows and displaces water from the sheet in a very efficient manner. The energy required for water removal is very much less than that required for conventional evaporative drying. To eliminate sheet delamination, low thermal mass ceramic press roll coatings were developed to reduce heat transfer to the sheet, while maintaining high heat flux during early stages of the process. In so doing, most of the transferred energy is used to form steam that displaces liquid water, rather than in excessively heating the sheet. During this period, a prototype ceramic coating was developed and its impulse drying performance was compared to that of steel surfaces. It was observed that ceramic platens can be operated at higher temperatures and pressures resulting in improved water removal and physical properties without inducing sheet delamination. Heat flux measurement techniques were developed to provide a mechanistic explanation for the superior performance of the prototype. The work confirmed that the prototype ceramic coating is more energy efficient than the steel surface.

  6. High-intensity drying processes-impulse drying. Yearly report

    Energy Technology Data Exchange (ETDEWEB)

    Orloff, D.I.

    1991-06-01

    Impulse drying is an innovative process for drying paper that holds great promise for reducing the energy consumed during the manufacture of paper and similar web products. impulse drying occurs when a wet paper web passes through a press nip in which one of the rolls is heated to a high temperature. A steam layer adjacent to the heated surface grows and displaces water from the sheet in a very efficient manner. The energy required for water removal is very much less than that required for conventional evaporative drying. To eliminate sheet delamination, low thermal mass ceramic press roll coatings were developed to reduce heat transfer to the sheet, while maintaining high heat flux during early stages of the process. In so doing, most of the transferred energy is used to form steam that displaces liquid water, rather than in excessively heating the sheet. During this period, a prototype ceramic coating was developed and its impulse drying performance was compared to that of steel surfaces. It was observed that ceramic platens can be operated at higher temperatures and pressures resulting in improved water removal and physical properties without inducing sheet delamination. Heat flux measurement techniques were developed to provide a mechanistic explanation for the superior performance of the prototype. The work confirmed that the prototype ceramic coating is more energy efficient than the steel surface.

  7. Data Intensive High Energy Physics Analysis in a Distributed Cloud

    CERN Document Server

    Sobie, R J; Anderson, M; Armstrong, P; Fransham, K; Gable, I; Harris, D; Leavett-Brown, C; Paterson, M; Penfold-Brown, D; Vliet, M; Charbonneau, A; Impey, R; Podaima, W

    2011-01-01

    We show that distributed Infrastructure-as-a-Service (IaaS) compute clouds can be effectively used for the analysis of high energy physics data. We have designed a distributed cloud system that works with any application using large input data sets requiring a high throughput computing environment. The system uses IaaS-enabled science and commercial clusters in Canada and the United States. We describe the process in which a user prepares an analysis virtual machine (VM) and submits batch jobs to a central scheduler. The system boots the user-specific VM on one of the IaaS clouds, runs the jobs and returns the output to the user. The user application accesses a central database for calibration data during the execution of the application. Similarly, the data is located in a central location and streamed by the running application. The system can easily run one hundred simultaneous jobs in an efficient manner and should scale to many hundreds and possibly thousands of user jobs.

  8. Relative Match Intensities at High Altitude in Highly-Trained Young Soccer Players (ISA3600

    Directory of Open Access Journals (Sweden)

    Martin Buchheit

    2015-03-01

    Full Text Available To compare relative match intensities of sea-level versus high-altitude native soccer players during a 2-week camp at 3600 m, data from 7 sea-level (Australian U17 National team, AUS and 6 high-altitude (a Bolivian U18 team, BOL native soccer players were analysed. Two matches were played at sea-level and three at 3600 m on Days 1, 6 and 13. The Yo-Yo Intermittent recovery test (vYo-YoIR1 was performed at sea-level, and on Days 3 and 10. Match activity profiles were measured via 10-Hz GPS. Distance covered >14.4 km.h-1 (D>14.4 km·h-1 and >80% of vYo-YoIR1 (D>80%vYo-YoIR1 were examined. Upon arrival at altitude, there was a greater decrement in vYo-YoIR1 (Cohen’s d +1.0, 90%CL ± 0.8 and D>14.4 km·h-1 (+0.5 ± 0.8 in AUS. D>14.4 km.h-1 was similarly reduced relative to vYo-YoIR1 in both groups, so that D>80%vYo-YoIR1 remained similarly unchanged (-0.1 ± 0.8. Throughout the altitude sojourn, vYo-YoIR1 and D>14.4 km·h-1 increased in parallel in AUS, so that D>80%vYo-YoIR1 remained stable in AUS (+6.0%/match, 90%CL ± 6.7; conversely D>80%vYo-YoIR1 decreased largely in BOL (-12.2%/match ± 6.2. In sea-level natives competing at high-altitude, changes in match running performance likely follow those in high-intensity running performance. Bolivian data confirm that increases in ‘fitness’ do not necessarily translate into greater match running performance, but rather in reduced relative exercise intensity.

  9. EFFECT OF HIGH & LOW INTENSITIES OF AEROBIC EXERCISE ON PHYSICAL FITNESS INDEX

    Directory of Open Access Journals (Sweden)

    Madhusudhan

    2015-06-01

    Full Text Available BACKGROUND: Aerobic exercise reduces body fat and improves weight control, increases HDL&Vo2 max. Also improves PFI (physical fitness index which is defined as ability to carry out daily tasks with vigour and alertness without undue fatigue. Though aerobic exercise is found to improve physical fitness, the relative merits of different intensities of aerobi c exercise in improving physical fitness is still uncertain. AIM: The present study was conducted to know the Effect of High & low intensity aerobic training on physical fitness index. MATERIALS & METHODS : 80 sedentary men (18 - 40 years were randomized in to 2 equal groups (High Intensity & low intensity group . The High [80% HR max] & Low intensity [50 % HR max] groups underwent aerobic exercise training using Bicycle ergo meter (COSCO at 900kpm & 540kpm, for 15mins/day & 30mins/day respectively, 5days a week, for a period of 14weeks. Physical fitness index of each subject was recorded by Modified Harvard step test before & after intervention. RESULTS : After 14 weeks of aerobic training both the exercise groups had improvement in PFI, but high intensity gr oup had a significant (p<0.05 improvement in PFI (97.18 - 101.14 than low intensity group (98.12 - 100.6. CONCLUSION : High intensity aerobic exercise is effective in improving physical fitness.

  10. High-protein diet induces oxidative stress in rat brain: protective action of high-intensity exercise against lipid peroxidation

    OpenAIRE

    Camiletti-Moir??n, Daniel; Aparicio Garc??a-Molina, Virginia A.; Nebot Valenzuela, Elena; Medina, Gerardo; Mart??nez, Rosario; Kapravelou, Garyfallia; Andrade, Ana; Porres-Foulquie, Jes??s; L??pez-Jurado, Mar??a; Aranda Ram??rez, Pilar

    2015-01-01

    diets as well as aerobic exercise could promote antioxidant capacity and consequently reduce free radicals overproduction on brain. However, little is know regarding to the high-protein diets and high intensity exercise on oxidative stress production. The aim of this study was to analyse the effects of high-protein diets and high-intensity exercise (HIE) on brain oxidative stress markers. Materials and Methods: A total of 40 male Wistar rats were randomly distributed i...

  11. Tools and techniques for estimating high intensity RF effects

    Science.gov (United States)

    Zacharias, Richard L.; Pennock, Steve T.; Poggio, Andrew J.; Ray, Scott L.

    1992-01-01

    Tools and techniques for estimating and measuring coupling and component disturbance for avionics and electronic controls are described. A finite-difference-time-domain (FD-TD) modeling code, TSAR, used to predict coupling is described. This code can quickly generate a mesh model to represent the test object. Some recent applications as well as the advantages and limitations of using such a code are described. Facilities and techniques for making low-power coupling measurements and for making direct injection test measurements of device disturbance are also described. Some scaling laws for coupling and device effects are presented. A method for extrapolating these low-power test results to high-power full-system effects are presented.

  12. Generating long sequences of high-intensity femtosecond pulses

    CERN Document Server

    Bitter, Martin

    2015-01-01

    We present an approach to create pulse sequences extending beyond 150~picoseconds in duration, comprised of $100~\\mu$J femtosecond pulses. A quarter of the pulse train is produced by a high-resolution pulse shaper, which allows full controllability over the timing of each pulse. Two nested Michelson interferometers follow to quadruple the pulse number and the sequence duration. To boost the pulse energy, the long train is sent through a multi-pass Ti:Sapphire amplifier, followed by an external compressor. A periodic sequence of 84~pulses of 120~fs width and an average pulse energy of 107~$\\mu$J, separated by 2~ps, is demonstrated as a proof of principle.

  13. Study of a final focus system for high intensity beams

    Energy Technology Data Exchange (ETDEWEB)

    Henestroza, Enrique; Eylon, Shmuel; Roy, Prabir K.; Yu, Simon S.; Bieniosek, Frank M.; Shuman, Derek B.; Waldron, William L.

    2004-06-01

    The NTX experiment at the Heavy Ion Fusion Virtual National Laboratory is exploring the performance of neutralized final focus systems for high perveance heavy ion beams. The final focus scenario in an HIF driver consists of several large aperture quadrupole magnets followed by a drift section in which the beam space charge is neutralized by a plasma. This beam is required to hit a millimeter-sized target spot at the end of the drift section. The objective of the NTX experiments and associated theory and simulations is to study the various physical mechanisms that determine the final spot size (radius r{sub s}) at a given distance (f) from the end of the last quadrupole. In a fusion driver, f is the standoff distance required to keep the chamber wall and superconducting magnets properly protected. The NTX final quadrupole focusing system produces a converging beam at the entrance to the neutralized drift section where it focuses to a small spot. The final spot is determined by the conditions of the beam entering the quadrupole section, the beam dynamics in the magnetic lattice, and the plasma neutralization dynamics in the drift section. The main issues are the control of emittance growth due to high order fields from magnetic multipoles and image fields. In this paper, we will describe the theoretical and experimental aspects of the beam dynamics in the quadrupole lattice, and how these physical effects influence the final beam size. In particular, we present theoretical and experimental results on the dependence of final spot size on geometric aberrations and perveance.

  14. Impact of High-intensity Intermittent and Moderate-intensity Continuous Exercise on Autonomic Modulation in Young Men.

    Science.gov (United States)

    Cabral-Santos, C; Giacon, T R; Campos, E Z; Gerosa-Neto, J; Rodrigues, B; Vanderlei, L C M; Lira, F S

    2016-06-01

    The aim of this study was to compare heart rate variability (HRV) recovery after two iso-volume (5 km) exercises performed at different intensities. 14 subjects volunteered (25.17±5.08 years; 74.7±6.28 kg; 175±0.05 cm; 59.56±5.15 mL·kg(-1)·min(-1)) and after determination of peak oxygen uptake (VO2Peak) and the speed associated with VO2Peak (sVO2Peak), the subjects completed 2 random experimental trials: high-intensity exercise (HIE - 1:1 at 100% sVO2Peak), and moderate-intensity continuous exercise (MIE - 70% sVO2Peak). HRV and RR intervals were monitored before, during and after the exercise sessions together with, the HRV analysis in the frequency domains (high-frequency - HF: 0.15 to 0.4 Hz and low-frequency - LF: 0.04 to 0.15 Hz components) and the ratio between them (LF/HF). Statistical analysis comparisons between moments and between HIE and MIE were performed using a mixed model. Both exercise sessions modified LFlog, HFlog, and LF/HF (F=16.54, F=19.32 and F=5.17, p<0.05, respectively). A group effect was also found for LFlog (F=23.91, p<0.05), and HFlog (F=57.55, p< 0.05). LF/HF returned to resting value 15 min after MIE exercise and 20 min after HIE exercise. This means that the heavy domain (aerobic and anaerobic threshold) induces dissimilar autonomic modification in physically active subjects. Both HIE and MIE modify HRV, and generally HIE delays parasympathetic autonomic modulation recovery after iso-volume exercise.

  15. Effect of preseason concurrent muscular strength and high-intensity interval training in professional soccer players.

    Science.gov (United States)

    Wong, Pui-lam; Chaouachi, Anis; Chamari, Karim; Dellal, Alexandre; Wisloff, Ulrik

    2010-03-01

    This study examined the effect of concurrent muscular strength and high-intensity running interval training on professional soccer players' explosive performances and aerobic endurance. Thirty-nine players participated in the study, where both the experimental group (EG, n = 20) and control group (CG, n = 19) participated in 8 weeks of regular soccer training, with the EG receiving additional muscular strength and high-intensity interval training twice per week throughout. Muscular strength training consisted of 4 sets of 6RM (repetition maximum) of high-pull, jump squat, bench press, back half squat, and chin-up exercises. The high-intensity interval training consisted of 16 intervals each of 15-second sprints at 120% of individual maximal aerobic speed interspersed with 15 seconds of rest. EG significantly increased (p aerobic speed test, and maximal aerobic speed. High-intensity interval running can be concurrently performed with high load muscular strength training to enhance soccer players' explosive performances and aerobic endurance.

  16. Improvement of high-voltage staircase drive circuit waveform for high-intensity therapeutic ultrasound

    Science.gov (United States)

    Tamano, Satoshi; Jimbo, Hayato; Azuma, Takashi; Yoshizawa, Shin; Fujiwara, Keisuke; Itani, Kazunori; Umemura, Shin-Ichiro

    2016-07-01

    Recently, in the treatment of diseases such as cancer, noninvasive or low-invasive modality, such as high-intensity focused ultrasound (HIFU), has been put into practice as an alternative to open surgery. HIFU induces thermal ablation of the target tissue to be treated. To improve the efficiency of HIFU, we have proposed a “triggered-HIFU” technique, which uses the combination of a short-duration, high-voltage transmission and a long-duration, medium-voltage transmission. In this method, the transmission device must endure high peak voltage for the former and the high time-average power for the latter. The triggered-HIFU sequence requires electronic scanning of the HIFU focus to maximize its thermal efficiency. Therefore, the transmission device must drive an array transducer with the number of elements on the order of a hundred or more, which requires that each part of the device that drives each element must be compact. The purpose of this work is to propose and construct such a transmission device by improving the staircase drive circuit, which we previously proposed. The main point of improvement is that both N and P MOSFETs are provided for each staircase voltage level instead of only one of them. Compared with the previous ultrasonic transmission circuit, high-voltage spikes were significantly reduced, the power consumption was decreased by 26.7%, and the transmission circuit temperature rise was decreased by 14.5 °C in the triggered-HIFU heating mode.

  17. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika;

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT...... performed 6-10 × 30 s all-out swimming interspersed by 2 min recovery and MOD swam continuously for 1 h at moderate intensity for a 15-week period completing in total 44 ± 1 and 43 ± 1 sessions, respectively. In CON, all measured variables were similar before and after the intervention period. Systolic BP...... swim (13 ± 3% and 22 ± 3%), interval swimming (23 ± 3% and 8 ± 3%), and Yo-Yo IE1 running performance (58 ± 5% and 45 ± 4%). In conclusion, high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance...

  18. Effect of high-intensity training on endothelial function in patients with cardiovascular and cerebrovascular disease

    DEFF Research Database (Denmark)

    Kolmos, Mia; Krawcyk, Rikke Steen; Kruuse, Christina

    2016-01-01

    OBJECTIVES: Exercise improves endothelial dysfunction, the key manifestation of cardiovascular and cerebrovascular disease, and is recommended in both cardiovascular and cerebrovascular rehabilitation. Disagreement remains, however, on the role of intensity of exercise. The purpose of this review...... was to gather current knowledge on the effects of high-intensity training versus moderate-intensity continuous exercise on endothelial function in cardiovascular and cerebrovascular patients. METHODS: A systematic review was performed in PubMed database, Embase and Cochrane libraries and on PEDro using...... the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies were restricted to cardiovascular and cerebrovascular patients, and healthy subjects as general reference. Interventions comprised of high-intensity training alone, high-intensity training compared to moderate...

  19. Short-term effects of implemented high intensity shoulder elevation during computer work

    Directory of Open Access Journals (Sweden)

    Madeleine Pascal

    2009-08-01

    Full Text Available Abstract Background Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction on productivity, RPE and upper trapezius activity and rest during computer work and a subsequent pause from computer work. Methods 18 female computer workers performed 2 sessions of 15 min standardized computer mouse work preceded by 1 min pause with and without prior high intensity contraction of shoulder elevation. RPE was reported, productivity (drawings per min measured, and bipolar surface electromyography (EMG recorded from the dominant upper trapezius during pauses and sessions of computer work. Repeated measure ANOVA with Bonferroni corrected post-hoc tests was applied for the statistical analyses. Results The main findings were that a high intensity shoulder elevation did not modify RPE, productivity or EMG activity of the upper trapezius during the subsequent pause and computer work. However, the high intensity contraction reduced the relative rest time of the uppermost (clavicular trapezius part during the subsequent pause from computer work (p Conclusion Since a preceding high intensity shoulder elevation did not impose a negative impact on perceived effort, productivity or upper trapezius activity during computer work, implementation of high intensity contraction during computer work to prevent neck-shoulder pain may be possible without affecting the working routines. However, the unexpected reduction in clavicular trapezius rest during a

  20. High-intensity interval versus moderate-intensity continuous training: Superior metabolic benefits in diet-induced obesity mice.

    Science.gov (United States)

    Wang, Ningning; Liu, Yang; Ma, Yanan; Wen, Deliang

    2017-08-23

    Exercise is beneficial in obesity, however, the debate about the value of high-intensity interval training (HIIT) vs. moderate-intensity continuous training (MICT) has been long lasting. Therefore, here we have compared the possible beneficial effects of two different exercise training regimes in a mouse model of diet-induced obesity (DIO). Following 7wk. on high fat diet (HFD), ten-week-old male ICR mice (n=30) were assigned to HIIT, distance-matched MICT or remained sedentary for the next 8 constitutive weeks while maintaining the dietary treatments. Age-matched sedentary mice with standard diet were used as a control (n=10). Exercise was performed on a motorized treadmill for 5days a week. Both modes of exercise ameliorated adiposity and related metabolic dysfunction induced by HFD and sedentary lifestyle, while mice following HIIT exhibited significantly lower body weight, percentage of fat mass and smaller adipocyte size. HIIT was more favorable in preventing liver lipid accumulation by restoring mRNA levels of genes involved in hepatic lipogenesis (SREBP1, ACC1, FAS) and β-oxidation (PPARα, CPT1a, HAD). In addition, HIIT was more efficient in mitigating adipose tissue inflammation and insulin insensitivity, partly dependent on abrogating phosphorylation of JNK/IRS1 (Ser307) pathway. Moreover, only HIIT led to pronounced beige adipocyte recruitment in inguinal subcutaneous adipose tissue. We conclude that HIIT contribute a more favorable regulation of metabolic dysfunctions in DIO mice compared with MICT. Copyright © 2017. Published by Elsevier Inc.

  1. A High Intensity Linac for the National Spallation Neutron Source

    Science.gov (United States)

    Jason, A.; Bhatia, T.; Billen, J.; Schrage, D.; Kurennoy, S.; Krawczyk, F.; Lynch, M.; Nath, S.; Shafer, R.; Takeda, H.; Tallerico, P.; Wangler, T.; Wood, R.; Young, L.; Grand, P.; McKenzie-Wilson, R.

    1997-05-01

    The National Spallation Neutron Source to be constructed at Oak Ridge National Laboratory, requires a linac capable of delivering up to 5 MW of beam power to an accumulator ring with a nominal 6.2% duty factor and an energy of 1 GeV. Los Alamos, responsible for the linac design, has developed an appropriate room-temperature linac that consists of a drift-tube section from 2.5 to 20 MeV, a coupled-cavity drift-tube section to 100 MeV, and a coupled-cavity section to 1 GeV. The initial scenario requires an average 1.1-mA beam current with a corresponding 28 mA peak current and a 1.2-Mhz chopped time structure corresponding to the ring period. Upgrade to a 4.4 mA average current requires funneling with a peak current of 112 mA in the high-energy sections. Further parameters are presented along with beam dynamics and structure choices and mechanical and rf engineering considerations.

  2. Diffraction Gratings for High-Intensity Laser Applications

    Energy Technology Data Exchange (ETDEWEB)

    Britten, J

    2008-01-23

    The scattering of light into wavelength-dependent discrete directions (orders) by a device exhibiting a periodic modulation of a physical attribute on a spatial scale similar to the wavelength of light has been the subject of study for over 200 years. Such a device is called a diffraction grating. Practical applications of diffraction gratings, mainly for spectroscopy, have been around for over 100 years. The importance of diffraction gratings in spectroscopy for the measurement of myriad properties of matter can hardly be overestimated. Since the advent of coherent light sources (lasers) in the 1960's, applications of diffraction gratings in spectroscopy have further exploded. Lasers have opened a vast application space for gratings, and apace, gratings have enabled entirely new classes of laser systems. Excellent reviews of the history, fundamental properties, applications and manufacturing techniques of diffraction gratings up to the time of their publication can be found in the books by Hutley (1) and more recently Loewen and Popov (2). The limited scope of this chapter can hardly do justice to such a comprehensive subject, so the focus here will be narrowly limited to characteristics required for gratings suitable for high-power laser applications, and methods to fabricate them. A particular area of emphasis will be on maximally-efficient large-aperture gratings for short-pulse laser generation.

  3. High Performance Data Transfer for Distributed Data Intensive Sciences

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Chin [Zettar Inc., Mountain View, CA (United States); Cottrell, R ' Les' A. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Hanushevsky, Andrew B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Kroeger, Wilko [SLAC National Accelerator Lab., Menlo Park, CA (United States); Yang, Wei [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2017-03-06

    We report on the development of ZX software providing high performance data transfer and encryption. The design scales in: computation power, network interfaces, and IOPS while carefully balancing the available resources. Two U.S. patent-pending algorithms help tackle data sets containing lots of small files and very large files, and provide insensitivity to network latency. It has a cluster-oriented architecture, using peer-to-peer technologies to ease deployment, operation, usage, and resource discovery. Its unique optimizations enable effective use of flash memory. Using a pair of existing data transfer nodes at SLAC and NERSC, we compared its performance to that of bbcp and GridFTP and determined that they were comparable. With a proof of concept created using two four-node clusters with multiple distributed multi-core CPUs, network interfaces and flash memory, we achieved 155Gbps memory-to-memory over a 2x100Gbps link aggregated channel and 70Gbps file-to-file with encryption over a 5000 mile 100Gbps link.

  4. A 3 GHz photoelectron gun for high beam intensity

    CERN Document Server

    Bossart, Rudolf; Dehler, M; Godot, J C

    1996-01-01

    For the Compact Linear Collider Test Facility (CTF) at CERN a new rf gun with a laser driven photocathode is under construction. The new rf gun will replace the present 11/2 cell gun and will consist of 21/2 cells accelerating the beam to a momentum of 7.0 MeV/c with an electric field strength of 100 MV/m. The strong space-charge forces at low beam energy caused by the high charge density of the electron bunches are contained by radial and longitudinal rf focusing in the gun. The rf gun under construction has been optimized by MAFIA beam simulations for an injector assembly comprising a second accelerating rf structure and an intermediate solenoid magnet correcting the beam divergence of the 21/2 cell gun. The beam loading of the rf gun, by a train of 48 bunches with 21 nC charge each, causes a strong energy decay accompanied by an increase of the flight time for the bunches with lower energy. These effects can be corrected by slightly shifting the acceleration frequency of the gun. The experimental results...

  5. Bremsstrahlung production with high-intensity laser matter interactions and applications

    NARCIS (Netherlands)

    Galy, J.; Maucec, M.; Hamilton, D. J.; Edwards, R.; Magill, J.

    2007-01-01

    In the last decade an evolution of experimental relativistic laser-plasma physics has led to highly sophisticated lasers, which are now able to generate ultra short pulses and can be focused to intensities in excess of 10(21) W cm(-2), with more than 500 J on target. In the intense electric field of

  6. Bremsstrahlung production with high-intensity laser matter interactions and applications

    NARCIS (Netherlands)

    Galy, J.; Maucec, M.; Hamilton, D. J.; Edwards, R.; Magill, J.

    2007-01-01

    In the last decade an evolution of experimental relativistic laser-plasma physics has led to highly sophisticated lasers, which are now able to generate ultra short pulses and can be focused to intensities in excess of 10(21) W cm(-2), with more than 500 J on target. In the intense electric field of

  7. Scoring system for the selection of high-risk patients in the intensive care unit

    NARCIS (Netherlands)

    Iapichino, G; Mistraletti, G; Corbella, D; Bassi, G; Borotto, E; Miranda, DR; Morabito, A

    2006-01-01

    Objective. Patients admitted to the intensive care unit greatly differ in severity and intensity of care. We devised a system for selecting high-risk patients that reduces bias by excluding low-risk patients and patients with an early death irrespective of the treatment. Design: A posteriori analysi

  8. Is moderate intensity exercise training combined with high intensity interval training more effective at improving cardiorespiratory fitness than moderate intensity exercise training alone?

    Science.gov (United States)

    Roxburgh, Brendon H; Nolan, Paul B; Weatherwax, Ryan M; Dalleck, Lance C

    2014-09-01

    The purpose of this study was to compare the effectiveness of either continuous moderate intensity exercise training (CMIET) alone vs. CMIET combined with a single weekly bout of high intensity interval training (HIIT) on cardiorespiratory fitness. Twenty nine sedentary participants (36.3 ± 6.9 yrs) at moderate risk of cardiovascular disease were recruited for 12 weeks of exercise training on a treadmill and cycle ergometer. Participants were randomised into three groups: CMIET + HIIT (n = 7; 8-12 x 60 sec at 100% VO2max, 150 sec active recovery), CMIET (n = 6; 30 min at 45-60% oxygen consumption reserve (VO2R)) and a sedentary control group (n = 7). Participants in the CMIET + HIIT group performed a single weekly bout of HIIT and four weekly sessions of CMIET, whilst the CMIET group performed five weekly CMIET sessions. Probabilistic magnitude-based inferences were determined to assess the likelihood that the true value of the effect represents substantial change. Relative VO2max increased by 10.1% (benefit possible relative to control) in in the CMIET + HIIT group (32.7 ± 9.2 to 36.0 ± 11.5 mL·kg(-1)·min(-1)) and 3.9% (benefit possible relative to control) in the CMIET group (33.2 ± 4.0 to 34.5 ± 6.1 mL·kg(-1)·min(-1)), whilst there was a 5.7% decrease in the control group (30.0 ± 4.6 to 28.3 ± 6.5 mL·kg(-1)·min(-1)). It was 'unclear' if a clinically significant difference existed between the effect of CMIET + HIIT and CMIET on the change in VO2max. Both exercising groups showed clinically meaningful improvements in VO2max. Nevertheless, it remains 'unclear' whether one type of exercise training regimen elicits a superior improvement in cardiorespiratory fitness relative to its counterpart. Key PointsBoth continuous moderate intensity exercise training (CMIET) alone and CMIET combined with a single weekly bout of high intensity interval training (CMIET + HIIT) elicit 'possibly beneficial' clinically meaningful improvements in cardiorespiratory

  9. Remote Sensing Tertiary Education Meets High Intensity Interval Training

    Science.gov (United States)

    Joyce, K. E.; White, B.

    2015-04-01

    Enduring a traditional lecture is the tertiary education equivalent of a long, slow, jog. There are certainly some educational benefits if the student is able to maintain concentration, but they are just as likely to get caught napping and fall off the back end of the treadmill. Alternatively, a pre-choreographed interactive workshop style class requires students to continually engage with the materials. Appropriately timed breaks or intervals allow students to recover briefly before being increasingly challenged throughout the class. Using an introductory remote sensing class at Charles Darwin University, this case study presents a transition from the traditional stand and deliver style lecture to an active student-led learning experience. The class is taught at undergraduate and postgraduate levels, with both on-campus as well as online distance learning students. Based on the concept that active engagement in learning materials promotes 'stickiness' of subject matter, the remote sensing class was re-designed to encourage an active style of learning. Critically, class content was reviewed to identify the key learning outcomes for the students. This resulted in a necessary sacrifice of topic range for depth of understanding. Graduates of the class reported high levels of enthusiasm for the materials, and the style in which the class was taught. This paper details a number of techniques that were used to engage students in active and problem based learning throughout the semester. It suggests a number of freely available tools that academics in remote sensing and related fields can readily incorporate into their teaching portfolios. Moreover, it shows how simple it can be to provide a far more enjoyable and effective learning experience for students than the one dimensional lecture.

  10. The high intensity solar cell: Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    The design considerations and performance characteristics of the 'high intensity' (HI) solar cell are presented. A high intensity solar system was analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency. It is shown that residential sized systems can be produced at less than $1000/kW peak electric power. Due to their superior high intensity performance characteristics compared to the conventional and VMJ cells, HI cells and light concentrators may be the key to low cost photovoltaic power.

  11. Monte-Carlo simulation of backscattered electrons in Auger electron spectroscopy. Part 1: Backscattering factor calculation

    Energy Technology Data Exchange (ETDEWEB)

    Tholomier, M.; Vicario, E.; Doghmane, N.

    1987-10-01

    The contribution of backscattered electrons to Auger electrons yield was studied with a multiple scattering Monte-Carlo simulation. The Auger backscattering factor has been calculated in the 5 keV-60 keV energy range. The dependence of the Auger backscattering factor on the primary energy and the beam incidence angle were determined. Spatial distributions of backscattered electrons and Auger electrons are presented for a point incident beam. Correlations between these distributions are briefly investigated.

  12. Improved highly accurate localized motion imaging for monitoring high-intensity focused ultrasound therapy

    Science.gov (United States)

    Qu, Xiaolei; Azuma, Takashi; Sugiyama, Ryusuke; Kanazawa, Kengo; Seki, Mika; Sasaki, Akira; Takeuchi, Hideki; Fujiwara, Keisuke; Itani, Kazunori; Tamano, Satoshi; Takagi, Shu; Sakuma, Ichiro; Matsumoto, Yoichiro

    2016-07-01

    Visualizing an area subjected to high-intensity focused ultrasound (HIFU) therapy is necessary for controlling the amount of HIFU exposure. One of the promising monitoring methods is localized motion imaging (LMI), which estimates coagulation length by detecting the change in stiffness. In this study, we improved the accuracy of our previous LMI by dynamic cross-correlation window (DCCW) and maximum vibration amount (MVA) methods. The DCCW method was used to increase the accuracy of estimating vibration amplitude, and the MVA method was employed to increase signal-noise ratio of the decrease ratio at the coagulated area. The qualitative comparison of results indicated that the two proposed methods could suppress the effect of noise. Regarding the results of the quantitative comparison, coagulation length was estimated with higher accuracy by the improved LMI method, and the root-mean-square error (RMSE) was reduced from 2.51 to 1.69 mm.

  13. Ultra-intense high orbital angular momentum harmonic generation in plasmas

    Science.gov (United States)

    Vieira, Jorge; Trines, R.; Alves, E. P.; Mendonca, J. T.; Fonseca, R. A.; Norreys, P.; Bigham, R.; Silva, L. O.

    2016-10-01

    As an independent degree of freedom, it is in principle possible to manipulate the orbital angular momentum (OAM) independently of any other laser property. The OAM therefore stands in equal foot to any other fundamental property of light, such as its frequency. There are, however, many open questions regarding the ability to control the OAM as an independent degree of freedom. A striking example is high harmonic generation, for which there is no OAM counterpart. Here we investigate a high OAM harmonics technique to generate and amplify high OAM harmonics while preserving the laser frequency. The scheme, based on simulated Raman backscattering, employs a linearly polarised long pump containing more than one OAM level, and a counter-propagating linearly polarised signal beam. The high OAM harmonics result from angular momentum cascading from modes with lower OAM to the modes with higher OAM. The OAM harmonics spectrum can be tailored according to the OAM contents of the pump. We illustrate the scheme with the generation of prime OAM harmonics, an all-optical realisation of the Green-Tao theorem. We support our theoretical findings with 3D particle-in-cell (PIC) simulations using Osiris.

  14. NOAA TIFF Image - 50m Backscatter, Charleston Bump - Deep Coral Priority Areas - Nancy Foster - (2006), UTM 17N NAD83

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains a unified GeoTiff with 30x30 meter cell size representing the backscatter intensity of the Charleston Bump off of the South Atlantic Bight,...

  15. NOAA TIFF Image - 3m Backscatter Mosaic, Florida Deep Coral Areas - Lost Coast Explorer - (2010), UTM 17N NAD83

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains a unified GeoTiff with 3x3 meter cell size representing the backscatter (intensity) of several deep coral priority areas off the Atlantic Coast...

  16. Meeting standards of high-quality intensive care unit palliative care: clinical performance and predictors.

    Science.gov (United States)

    Penrod, Joan D; Pronovost, Peter J; Livote, Elayne E; Puntillo, Kathleen A; Walker, Amy S; Wallenstein, Sylvan; Mercado, Alice F; Swoboda, Sandra M; Ilaoa, Debra; Thompson, David A; Nelson, Judith E

    2012-04-01

    High-quality care for intensive care unit patients and families includes palliative care. To promote performance improvement, the Agency for Healthcare Research and Quality's National Quality Measures Clearinghouse identified nine evidence-based processes of intensive care unit palliative care (Care and Communication Bundle) that are measured through review of medical record documentation. We conducted this study to examine how frequently the Care and Communication Bundle processes were performed in diverse intensive care units and to understand patient factors that are associated with such performance. Prospective, multisite, observational study of performance of key intensive care unit palliative care processes. A surgical intensive care unit and a medical intensive care unit in two different large academic health centers and a medical-surgical intensive care unit in a medium-sized community hospital. Consecutive adult patients with length of intensive care unit stay ≥5 days. None. Between November 2007 and December 2009, we measured performance by specified day after intensive care unit admission on nine care process measures: Identify medical decision-maker, advance directive and resuscitation preference, distribute family information leaflet, assess and manage pain, offer social work and spiritual support, and conduct interdisciplinary family meeting. Multivariable regression analysis was used to determine predictors of performance of five care processes. We enrolled 518 (94.9%) patients and 336 (83.6%) family members. Performances on pain assessment and management measures were high. In contrast, interdisciplinary family meetings were documented for <20% of patients by intensive care unit day 5. Performance on other measures ranged from 8% to 43%, with substantial variation across and within sites. Chronic comorbidity burden and site were the most consistent predictors of care process performance. Across three intensive care units in this study, performance

  17. Inverse bremsstrahlung absorption with nonlinear effects of high laser intensity and non-Maxwellian distribution.

    Science.gov (United States)

    Weng, Su-Ming; Sheng, Zheng-Ming; Zhang, Jie

    2009-11-01

    Inverse bremsstrahlung (IB) absorption and evolution of the electron distribution function (EDF) in a wide laser intensity range (10;{12}-10;{17} W/cm;{2}) have been studied systematically by a two velocity-dimension Fokker-Planck code. It is found that Langdon's IB operator overestimates the absorption rate at high laser intensity, consequently with an overdistorted non-Maxwellian EDF. According to the small anisotropy of EDF in the oscillation frame, we introduce an IB operator which is similar to Langdon's but without the low laser intensity limit. This operator is appropriate for self-consistently tackling the nonlinear effects of high laser intensity as well as non-Maxwellian EDF. Particularly, our operator is capable of treating IB absorption properly in the indirect and direct-drive inertial confinement fusion schemes with the National Ignition Facility and Laser MegaJoule laser parameters at focused laser intensity beyond 10;{15} W/cm;{2} .

  18. High-density operation of the Proto-MPEX High Intensity Plasma Source

    Science.gov (United States)

    Caughman, J. B. O.; Goulding, R. H.; Biewer, T. M.; Bigelow, T. S.; Campbell, I. H.; Caneses, J.; Diem, S. J.; Martin, E. H.; Parish, C. M.; Rapp, J.; Ray, H. B.; Shaw, G. C.; Showers, M. A.; Donovan, D.; Piotrowicz, P. A.; Martin, D. C.

    2016-10-01

    The Prototype Materials Plasma Experiment (Proto-MPEX) is a linear high-intensity RF plasma source that combines a high-density helicon plasma generator with ion and electron heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration with the goal of delivering a plasma heat flux of 10 MW/m2 at a target. The helicon plasma is produced by coupling 13.56 MHz RF power at levels of >100 kW. A 30 kW ion cyclotron antenna has recently been installed, and microwaves at 28 GHz ( 150 kW) are coupled to the electrons in the over-dense helicon plasma via Electron Bernstein Waves (EBW). High plasma densities near the target have been produced in D ( 5 x1019/m3) , and electron temperatures range from 3 to >10 eV, depending on the source parameters. IR camera images of the target plate indicate plasma heat depositions >10 MW/m2 for some operating conditions. Details of the experimental results of the operational domain with respect to Te and ne as well as results from initial plasma material interaction tests will be presented. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  19. High-Intensity Interval Training Versus Moderate-Intensity Continuous Training in the Prevention/Management of Cardiovascular Disease.

    Science.gov (United States)

    Hussain, Syed R; Macaluso, Andrea; Pearson, Stephen J

    Moderate-intensity continuous training (MICT) has long been considered the most effective exercise treatment modality for the prevention and management of cardiovascular disease (CVD), but more recently high-intensity interval training (HIIT) has been viewed as a potential alternative to MICT in accruing such benefits. HIIT was initially found to induce significant improvements in numerous physiological and health-related indices, to a similar if not superior extent to MICT. Since then, many studies have attempted to explore the potential clinical utility of HIIT, relative to MICT, with respect to treating numerous cardiovascular conditions, such as coronary artery disease, heart failure, stroke, and hypertension. Despite this, however, the efficacy of HIIT in reversing the specific symptoms and risk factors of these cardiovascular pathologies is not well understood. HIIT is often perceived as very strenuous, which could render it unsafe for those at risk of or afflicted with CVD, but these issues are also yet to be reviewed. Furthermore, the optimal HIIT protocol for each of the CVD cohorts has not been established. Thus, the purpose of this review article is to (1) evaluate the efficacy of HIIT relative to MICT in the prevention and management of cardiovascular conditions, and (2) explore any potential safety issues surrounding the suitability and/or tolerability of HIIT for patients with CVD, and the potential optimal prescriptive variables of HIIT for application in the clinical environment.

  20. Intensive lifestyle intervention including high-intensity interval training program improves insulin resistance and fasting plasma glucose in obese patients.

    Science.gov (United States)

    Marquis-Gravel, Guillaume; Hayami, Douglas; Juneau, Martin; Nigam, Anil; Guilbeault, Valérie; Latour, Élise; Gayda, Mathieu

    2015-01-01

    To analyze the effects of a long-term intensive lifestyle intervention including high-intensity interval training (HIIT) and Mediterranean diet (MedD) counseling on glycemic control parameters, insulin resistance and β-cell function in obese subjects. The glycemic control parameters (fasting plasma glucose, glycated hemoglobin), insulin resistance, and β-cell function of 72 obese subjects (54 women; mean age = 53 ± 9 years) were assessed at baseline and upon completion of a 9-month intensive lifestyle intervention program conducted at the cardiovascular prevention and rehabilitation center of the Montreal Heart Institute, from 2009 to 2012. The program included 2-3 weekly supervised exercise training sessions (HIIT and resistance exercise), combined to MedD counseling. Fasting plasma glucose (FPG) (mmol/L) (before: 5.5 ± 0.9; after: 5.2 ± 0.6; P fasting insulin (pmol/L) (before: 98 ± 57; after: 82 ± 43; P = 0.003), and insulin resistance, as assessed by the HOMA-IR score (before: 3.6 ± 2.5; after: 2.8 ± 1.6; P = 0.0008) significantly improved, but not HbA1c (%) (before: 5.72 ± 0.55; after: 5.69 ± 0.39; P = 0.448), nor β-cell function (HOMA-β, %) (before: 149 ± 78; after: 144 ± 75; P = 0.58). Following a 9-month intensive lifestyle intervention combining HIIT and MedD counseling, obese subjects experienced significant improvements of FPG and insulin resistance. This is the first study to expose the effects of a long-term program combining HIIT and MedD on glycemic control parameters among obese subjects.

  1. Control of coherent backscattering by breaking optical reciprocity

    CERN Document Server

    Bromberg, Y; Popoff, S M; Cao, H

    2015-01-01

    Reciprocity is a universal principle that has a profound impact on many areas of physics. A fundamental phenomenon in condensed-matter physics, optical physics and acoustics, arising from reciprocity, is the constructive interference of quantum or classical waves which propagate along time-reversed paths in disordered media, leading to, for example, weak localization and metal-insulator transition. Previous studies have shown that such coherent effects are suppressed when reciprocity is broken. Here we show that by breaking reciprocity in a controlled manner, we can tune, rather than simply suppress, these phenomena. In particular, we manipulate coherent backscattering of light, also known as weak localization. By utilizing a non-reciprocal magneto-optical effect, we control the interference between time-reversed paths inside a multimode fiber with strong mode mixing, and realize a continuous transition from the well-known peak to a dip in the backscattered intensity. Our results may open new possibilities fo...

  2. Coherent inelastic backscattering of laser light from three isotropic atoms

    CERN Document Server

    Ketterer, Andreas; Shatokhin, Vyacheslav N

    2014-01-01

    We study the impact of double and triple scattering contributions on coherent backscattering of laser light from saturated isotropic atoms, in the helicity preserving polarization channel. Using the recently proposed diagrammatic pump-probe approach, we analytically derive single-atom spectral responses to a classical polychromatic driving field, combine them self-consistently to double and triple scattering processes, and numerically deduce the corresponding elastic and inelastic spectra, as well as the total backscattered intensities. We find that account of the triple scattering contribution leads to a faster decay of phase-coherence with increasing saturation of the atomic transition as compared to double scattering alone, and to a better agreement with the experiment on strontium atoms.

  3. Endurance capacity and neuromuscular fatigue following high- vs moderate-intensity endurance training: A randomized trial.

    Science.gov (United States)

    O'Leary, T J; Collett, J; Howells, K; Morris, M G

    2017-02-16

    High-intensity exercise induces significant central and peripheral fatigue; however, the effect of endurance training on these mechanisms of fatigue is poorly understood. We compared the effect of cycling endurance training of disparate intensities on high-intensity exercise endurance capacity and the associated limiting central and peripheral fatigue mechanisms. Twenty adults were randomly assigned to 6 weeks of either high-intensity interval training (HIIT, 6-8×5 minutes at halfway between lactate threshold and maximal oxygen uptake [50%Δ]) or volume-matched moderate-intensity continuous training (CONT, ~60-80 minutes at 90% lactate threshold). Two time to exhaustion (TTE) trials at 50%Δ were completed pre- and post-training to assess endurance capacity; the two post-training trials were completed at the pretraining 50%Δ (same absolute intensity) and the "new" post-training 50%Δ (same relative intensity). Pre- and post-exercise responses to femoral nerve and motor cortex stimulation were examined to determine peripheral and central fatigue, respectively. HIIT resulted in greater increases in TTE at the same absolute and relative intensities as pre-training (148% and 43%, respectively) compared with CONT (38% and -4%, respectively) (P≤.019). Compared with pre-training, HIIT increased the level of potentiated quadriceps twitch reduction (-34% vs -43%, respectively, P=.023) and attenuated the level of voluntary activation reduction (-7% vs -3%, respectively, P=.047) following the TTE trial at the same relative intensity. There were no other training effects on neuromuscular fatigue development. This suggests that central fatigue resistance contributes to enhanced high-intensity exercise endurance capacity after HIIT by allowing greater performance to be extruded from the muscle. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. High-intensity focused ultrasound treatment of abnormal vaginal bleeding secondary to uterine myoma.

    Science.gov (United States)

    Lim, Jung Hyun; Chung, Dong Jin; Lim, Young Tec; Cho, Sae Hyun; Lee, Jae Mun; Hahn, Seong-Tae

    2011-03-01

    We describe the use of high-intensity focused ultrasound for acute vaginal bleeding secondary to uterine myoma in 2 young female patients. Both patients had episodes of abnormal vaginal bleeding with severe dysmenorrhea that was not efficiently controlled by medical treatment. After high-intensity focused ultrasound ablation, both vaginal bleeding control and symptom relief were achieved without postinterventional complications. The patients remained free of symptoms during 2 months of follow-up and regained normal menstruation after high-intensity focused ultrasound therapy. High-intensity focused ultrasound treatment is one of the least invasive options for dysfunctional vaginal bleeding and may be an effective and safe alternative to other procedures in women of reproductive age with abnormal vaginal bleeding secondary to uterine myoma.

  5. High speed traveling wave electrooptic intensity modulator with a doped PIN semiconductor junction

    Energy Technology Data Exchange (ETDEWEB)

    Vawter, G.A.; Hietala, V.M.; Wendt, J.R.; Fuchs, B.A.; Hafich, M.; Housel, M.; Armendariz, M.; Sullivan, C.T.

    1996-02-01

    A high-electrooptic-efficiency Mach-Zehnder intensity modulator is demonstrated with a bandwidth exceeding 40 GHZ. The 1 mm-long modulator has a switching voltage comparable to undoped semiconductor designs of much greater length.

  6. Effect of low-intensity extremely high frequency radiation on reproductive function in wistar rats.

    Science.gov (United States)

    Subbotina, T I; Tereshkina, O V; Khadartsev, A A; Yashin, A A

    2006-08-01

    The exposure to low-intensity extremely high frequency electromagnetic radiation during spermatogenesis was accompanied by pathological changes, which resulted in degeneration and polymorphism of spermatozoa. The number of newborn rats increased in the progeny of irradiated animals.

  7. Enhancement of High-Intensity Focused Ultrasound Heating by Short-Pulse Generated Cavitation

    Directory of Open Access Journals (Sweden)

    Shin Yoshizawa

    2017-03-01

    Full Text Available A target tissue can be thermally coagulated in high-intensity focused ultrasound (HIFU treatment noninvasively. HIFU thermal treatments have been clinically applied to various solid tumors. One of the problems in HIFU treatments is a long treatment time. Acoustically driven microbubbles can accelerate the ultrasonic heating, resulting in the significant reduction of the treatment time. In this paper, a method named “trigger HIFU exposure” which employs cavitation microbubbles is introduced and its results are reviewed. A trigger HIFU sequence consists of high-intensity short pulses followed by moderate-intensity long bursts. Cavitation bubbles induced in a multiple focal regions by rapidly scanning the focus of high-intensity pulses enhanced the temperature increase significantly and produced a large coagulation region with high efficiency.

  8. High-Intensity Intermittent Exercise: Effect on Young People's Cardiometabolic Health and Cognition.

    Science.gov (United States)

    Cooper, Simon B; Dring, Karah J; Nevill, Mary E

    2016-01-01

    With only a quarter of young people currently meeting physical activity guidelines, two key areas of concern are the effects of exercise on cardiometabolic health and cognition. Despite the fact that physical activity in young people is typically high intensity and intermittent in nature, much of the literature examines traditional endurance-type exercise. This review provides an update on the effects of high-intensity intermittent exercise on young people's cardiometabolic health and cognition. High-intensity intermittent exercise has acute beneficial effects on endothelial function and postprandial lipemia and chronic positive effects on weight management. In addition, there is emerging evidence regarding chronic benefits on the blood lipid profile, blood pressure, and proinflammatory and anti-inflammatory cytokines. Furthermore, emerging evidence suggests beneficial acute and chronic effects of high-intensity intermittent exercise on cognition. However, further research is required in both cardiometabolic health and cognition, particularly regarding the impact of school-based interventions in adolescents.

  9. Influence of mature men way of life on highly intensive physical activity

    Directory of Open Access Journals (Sweden)

    O.B. Pryshva

    2017-04-01

    Full Text Available Highly intensive physical activity is the most effective for men’s health protection. In modern life conditions its level is insufficient. It requires organism’s appropriate physical activity, which is determined by way of life. Especially important it is before trainings. Purpose: to study special aspects of different intensity’s physical activity; of eating special food and sleeping regime of mature men before their highly intensive physical trainings. Material: in experiment men (n=26, age - 35-53years, who practice healthy life style and independent physical activity of high intensity, participated. We used bio-register Basis B1. Every day we registered: Peak - physical activity of different intensity; duration and quality of sleep; relative weight of consumed food. Besides, we calculated body mass index and physical condition. The study was conducted during 30 days in winter period. The following results were compared: indicators before not planned physical activity and average-monthly indicators. Results: Before arbitrary physical functioning we found in men: confident weakening of average intensity (by 9-11% and low intensity (by 10% physical activity; confident increase of consumed food’s relative weight (by 6.82%, vegetarian food (by 10.64% and raw food (by 7.61%; confident reduction of animal origin food (by 8.7%. No changes were found in duration and quality of sleep before highly intensive physical functioning. Conclusions: specific features of mature men’s way of life before their not planned highly intensive physical functioning are as follows: reduction of general physical activity; increase of consumed food. These factors facilitate energy accumulation in organism for its realization in highly intensive physical functioning the next day.

  10. Design and implementation of capacitive micromachined ultrasonic transducers for high intensity focused ultrasound

    OpenAIRE

    Yamaner, Yalçın Feysel; Yamaner, Yalcin Feysel

    2011-01-01

    High intensity focused ultrasound (HIFU) is a medical procedure for noninvasive treatment of cancers. High intensity focused ultrasound is used to heat and destroy the diseased tissue. Piezoelectricity has been the core mechanism for generation of ultrasound waves in the treatment. Focusing can be done by using spherically curved transducers or using a lens or electronically steering sound waves by using phased arrays. Current research in HIFU technology targets the development of MR-guided m...

  11. Design concept of radiation control system for the high intensity proton accelerator facility

    CERN Document Server

    Miyamoto, Y; Harada, Y; Ikeno, K

    2002-01-01

    Description is given for the characteristic radiation environment for the High Intensity Proton Accelerator Facility and the design concept of the radiation control system of it. The facility is a large scale accelerator complex consisting of high energy proton accelerators carrying the highest beam intensity in the world and the related experimental facilities and therefore provides various issues relevant to the radiation environment. The present report describes the specifications for the radiation control system for the facility, determined in consideration of these characteristics.

  12. No Effect of Exercise Intensity on Appetite in Highly-Trained Endurance Women

    OpenAIRE

    Howe, Stephanie M; Taryn M. Hand; D. Enette Larson-Meyer; Kathleen J. Austin; Alexander, Brenda M.; Melinda M. Manore

    2016-01-01

    In endurance-trained men, an acute bout of exercise is shown to suppress post-exercise appetite, yet limited research has examined this response in women. The purpose of this study was to investigate the effect of exercise intensity on appetite and gut hormone responses in endurance-trained women. Highly-trained women (n = 15, 18–40 years, 58.4 ± 6.4 kg, VO2MAX = 55.2 ± 4.3 mL/kg/min) completed isocaloric bouts (500 kcals or 2093 kJ) of moderate-intensity (MIE, 60% VO2MAX) and high-intensity ...

  13. Associations of Low- and High-Intensity Light Activity with Cardiometabolic Biomarkers.

    Science.gov (United States)

    Howard, Bethany; Winkler, Elisabeth A H; Sethi, Parneet; Carson, Valerie; Ridgers, Nicola D; Salmon, J O; Healy, Genevieve N; Owen, Neville; Dunstan, David W

    2015-10-01

    Light-intensity physical activity (LIPA) accounts for much of adults' waking hours (≈40%) and substantially contributes to overall daily energy expenditure. Encompassing activity behaviors of low intensity (standing with little movement) to those of higher intensity (slow walking), LIPA is ubiquitous, yet little is known about how associations with health may vary depending on its intensity. We examined the associations of objectively assessed LIPA (categorized as either low LIPA [LLPA] or high LIPA [HLPA]) and moderate- to vigorous-intensity activity with cardiometabolic risk biomarkers. Cardiometabolic biomarkers were measured in 4614 US adults (47 ± 17 yr) who participated in the 2003-2004 and 2005-2006 National Health and Nutrition Examination Survey cycles. Multiple linear regression analyses examined the associations of three accelerometer-derived physical activity (SD increment per day) intensity categories (LLPA, 100-761 counts per minute; HLPA, 762-1951 counts per minute; moderate-intensity physical activity [MPA], 1952-5724 counts per minute; vigorous-intensity physical activity [VPA], ≥5725 counts per minute) with cardiometabolic biomarkers, adjusting for potential sociodemographic, behavioral, and medical confounders. All intensities of physical activity were beneficially associated with waist circumference, C-reactive protein, triglycerides, fasting insulin, β-cell function, and insulin sensitivity (P activity intensities showed significant associations with systolic blood pressure (LLPA), body mass index, HDL cholesterol, fasting glucose, and 2-h plasma glucose (HLPA, MPA, and VPA). Generally, effect size increased with intensity of physical activity. Overall, further adjustment for waist circumference attenuated associations with MPA and VPA to a greater extent than associations with LLPA and HLPA. The cross-sectional findings provide novel evidence for the potential benefits of increasing both LLPA and HLPA. They further reinforce the

  14. High-intensity exercise attenuates postprandial lipaemia and markers of oxidative stress.

    Science.gov (United States)

    Gabriel, Brendan; Ratkevicius, Aivaras; Gray, Patrick; Frenneaux, Michael P; Gray, Stuart R

    2012-09-01

    Regular exercise can reduce the risk of CVD (cardiovascular disease). Although moderate-intensity exercise can attenuate postprandial TAG (triacylglycerol), high-intensity intermittent exercise might be a more effective method to improve health. We compared the effects of high-intensity intermittent exercise and 30 min of brisk walking on postprandial TAG, soluble adhesion molecules and markers of oxidative stress. Nine men each completed three 2-day trials. On day 1, subjects rested (control), walked briskly for 30 min (walking) or performed 5×30 s maximal sprints (high-intensity). On day 2, subjects consumed a high-fat meal for breakfast and 3 h later for lunch. Blood samples were taken at various times and analysed for TAG, glucose, insulin, ICAM-1 (intracellular adhesion molecule-1), VCAM-1 (vascular adhesion molecule-1), TBARS (thiobarbituric acid- reactive substances), protein carbonyls and β-hydroxybutyrate. On day 2 of the high-intensity trial, there was a lower (Phigh-intensity trial (14.13±2.83 mmol/l per 7 h) compared with control (17.18±3.92 mmol/l per 7 h), walking showed no difference (16.33±3.51 mmol/l per 7 h). On day 2 of the high-intensity trial plasma TBARS and protein carbonyls were also reduced (Phigh-intensity intermittent exercise attenuates postprandial TAG and markers of oxidative stress after the consumption of a high-fat meal.

  15. EFFECT OF HIGH INTENSITY INTERVAL TRAINING ON ENDOTHELIAL FUNCTION IN POSTMENOPAUSAL HYPERTENSIVE PATIENTS RANDOMIZED CONTROLLED TRIAL

    Directory of Open Access Journals (Sweden)

    Mona Mohamed Taha

    2016-02-01

    Full Text Available Background: Postmenopausal hypertension is the most common risk factor of cardiovascular morbidity and mortality. As the exercises training conveys benefits of the setting of secondary prevention of hypertension. High intensity interval training (HIIT emerged as a new form of physical training and presents as therapeutic alternative to patients and health care professionals. This study aimed to investigate the effect of high intensity interval training on endothelial function in postmenopausal hypertension. Methods: Forty six mildly hypertensive postmenopausal women, their ages ranged from (45-55 years old, were randomly allocated to two groups: HIIT group (group-I; n=23 performed a high intensity interval training 3 times a week for 10 weeks at an intensity of (80-85% HR max for 40 minutes and control group (group-II; n=23 remains sedentary during this period. Serum nitric oxide (NO, vascular endothelial growth factor levels (VEGF and blood pressures were measured before and after intervention. Results: A significant reduction in both systolic and diastolic blood pressure values by 9.5% and 7 % respectively, was seen after high intensity interval training which was accompanied by increase in NO and VEGF levels by 43.3% and 15.2 % respectively, while no significant change observed in the control group. Conclusion: High intensity interval training had obvious benefits in improving plasma No, VEGF concentrations and controlling hypertension in postmenopausal women.

  16. Study in Parkinson Disease of Exercise (SPARX): Translating high-intensity exercise from animals to humans

    Science.gov (United States)

    Moore, Charity G.; Schenkman, Margaret; Kohrt, Wendy M.; Delitto, Anthony; Hall, Deborah A.; Corcos, Daniel

    2013-01-01

    A burgeoning literature suggests that exercise has a therapeutic benefit in persons with Parkinson disease (PD) and in animal models of PD, especially when animals exercise at high intensity. If exercise is to be prescribed as “first-line” or “add-on” therapy in patients with PD, we must demonstrate its efficacy and dose-response effects through testing phases similar to those used in the testing of pharmacologic agents. The SPARX Trial is a multicenter, randomized, controlled, single-blinded, Phase II study that we designed to test the feasibility of using high-intensity exercise to modify symptoms of PD and to simultaneously test the nonfutility of achieving a prespecified change in patients’ motor scores on the Unified Parkinson Disease Rating Scale (UPDRS). The trial began in May 2102 and is in the process of screening, enrolling, and randomly assigning 126 patients with early-stage PD to 1 of 3 groups: usual care (wait-listed controls), moderate-intensity exercise (4 days/week at 60%–65% maximal heart rate [HRmax]), or high-intensity exercise (4 days/week at 80%–85% HRmax). At 6-month follow-up, the trial is randomly reassigning usual care participants to a moderate-intensity or high-intensity exercise group for the remaining 6 months. The goals of the Phase II trial are to determine if participants can exercise at moderate and high intensities; to determine if either exercise yields benefits consistent with meaningful clinical change (nonfutility); and to document safety and attrition. The advantage of using a non-futility approach allows us to efficiently determine if moderate- or high-intensity exercise warrants further large-scale investigation in PD. PMID:23770108

  17. High-intensity erotic visual stimuli de-activate the primary visual cortex in women.

    Science.gov (United States)

    Huynh, Hieu K; Beers, Caroline; Willemsen, Antoon; Lont, Erna; Laan, Ellen; Dierckx, Rudi; Jansen, Monique; Sand, Michael; Weijmar Schultz, Willibrord; Holstege, Gert

    2012-06-01

    The primary visual cortex, Brodmann's area (BA 17), plays a vital role in basic survival mechanisms in humans. In most neuro-imaging studies in which the volunteers have to watch pictures or movies, the primary visual cortex is similarly activated independent of the content of the pictures or movies. However, in case the volunteers perform demanding non-visual tasks, the primary visual cortex becomes de-activated, although the amount of incoming visual sensory information is the same. Do low- and high-intensity erotic movies, compared to neutral movies, produce similar de-activation of the primary visual cortex? Brain activation/de-activation was studied by Positron Emission Tomography scanning of the brains of 12 healthy heterosexual premenopausal women, aged 18-47, who watched neutral, low- and high-intensity erotic film segments. We measured differences in regional cerebral blood flow (rCBF) in the primary visual cortex during watching neutral, low-intensity erotic, and high-intensity erotic film segments. Watching high-intensity erotic, but not low-intensity erotic movies, compared to neutral movies resulted in strong de-activation of the primary (BA 17) and adjoining parts of the secondary visual cortex. The strong de-activation during watching high-intensity erotic film might represent compensation for the increased blood supply in the brain regions involved in sexual arousal, also because high-intensity erotic movies do not require precise scanning of the visual field, because the impact is clear to the observer. © 2012 International Society for Sexual Medicine.

  18. High intensity polarization entangled source with a 2D nonlinear photonic crystal

    DEFF Research Database (Denmark)

    Wang, Qin

    2009-01-01

    We gave a proposal on how to use a piece of two-dimension (2D) nonlinear photonic crystal to generate a polarization entangled source. It provides not only has a high stability, but also a high entangled quality and a high intensity. Moreover, our scheme involves only practical experimental...

  19. Optical backscattering properties of the "clearest" natural waters

    Directory of Open Access Journals (Sweden)

    M. S. Twardowski

    2007-07-01

    depths between 300 and 350 m, from 23.5° S, 118° W to 26° S, 114° W, where total backscattering at 650 nm was not distinguishable from pure seawater; – Distributions of particulate backscattering bbp across the central gyre exhibited a broad particle peak centered ~100 m;
    – The particulate backscattering ratio typically ranged between 0.4% and 0.6% through the majority of the central gyre from the surface to ~210 m, indicative of "soft" water-filled particles with low bulk refractive index; and
    bbp at 532 and 650 nm showed a distinct secondary deeper layer centered ~230 m that was absent in particulate attenuation cp data. The particulate backscattering ratio was significantly higher in this layer than in the rest of the water column, reaching 1.2% in some locations. This high relative backscattering, along with the pigment composition and ecological niche of this layer, appear to be consistent with the coccolithophorid F. profunda.

    Moreover, results were consistent with several expectations extrapolated from theory and previous work in oceanic and coastal regions, supporting the conclusion that particulate and total backscattering could be resolved in these extremely clear natural waters.

  20. Optical backscattering properties of the "clearest" natural waters

    Directory of Open Access Journals (Sweden)

    M. S. Twardowski

    2007-11-01

    , 118° W to 26° S, 114° W, where total backscattering at 650 nm was not distinguishable from pure seawater;
    –Distributions of particulate backscattering bbp across the central gyre exhibited a broad particle peak centered ~100 m;
    –The particulate backscattering ratio typically ranged between 0.4% and 0.6% at 650 nm through the majority of the central gyre from the surface to ~210 m, indicative of "soft" water-filled particles with low bulk refractive index; and
    – bbp showed a distinct secondary deeper layer centered ~230 m that was absent in particulate attenuation cp data. The particulate backscattering ratio was significantly higher in this layer than in the rest of the water column, reaching 1.2% in some locations. This high relative backscattering, along with the pigment composition and ecological niche of this layer, appear to be consistent with the coccolithophorid Florisphaera profunda.

    Moreover, results were consistent with several expectations extrapolated from theory and previous work in oceanic and coastal regions, supporting the conclusion that particulate and total backscattering could be resolved in these extremely clear natural waters.

  1. Two weeks of moderate intensity continuous training, but not high intensity interval training increases insulin-stimulated intestinal glucose uptake.

    Science.gov (United States)

    Motiani, Kumail Kumar; Savolainen, Anna M; Eskelinen, Jari-Joonas; Toivanen, Jussi; Ishizu, Tamiko; Yli-Karjanmaa, Minna; Virtanen, Kirsi A; Parkkola, Riitta; Kapanen, Jukka; Gronroos, Tove J; Haaparanta-Solin, Merja; Solin, Olof; Savisto, Nina; Ahotupa, Markku; Löyttyniemi, Eliisa; Knuuti, Juhani; Nuutila, Pirjo; Kalliokoski, Kari K; Hannukainen, Jarna C

    2017-02-09

    Similar to muscles, the intestine is also insulin resistant in obese subjects and subjects with impaired glucose tolerance. Exercise training improves muscle insulin sensitivity, but its effects on intestinal metabolism are not known. We studied the effects of high intensity interval training (HIIT) and moderate intensity continuous training (MICT) on intestinal glucose and free fatty acid uptake from circulation in humans. Twenty-eight healthy middle-aged sedentary men were randomized for two weeks of HIIT or MICT. Intestinal insulin-stimulated glucose uptake and fasting free fatty acid uptake from circulation were measured using positron emission tomography and [(18)F]FDG and [(18)F]FTHA. In addition, effects of HIIT and MICT on intestinal Glut2 and CD36 protein expression were studied in rats. Training improved aerobic capacity (p=0.001) and whole-body insulin sensitivity (p=0.04), but not differently between HIIT and MICT. Insulin-stimulated glucose uptake increased only after the MICT in the colon [HIIT=0%; MICT=37%] (p=0.02 for time*training) and tended to increase in the jejunum [HIIT=-4%; MICT=13%] (p=0.08 for time*training). Fasting free fatty acid uptake decreased in the duodenum in both groups [HIIT=-6%; MICT=-48%] (p=0.001 time) and tended to decrease in the colon in the MICT group [HIIT=0%; MICT=-38%] (p=0.08 for time*training). In rats, both training groups had higher Glut2 and CD36 expression compared to control animals. This study shows that already two weeks of MICT enhances insulin-stimulated glucose uptake while both training modes reduce fasting free fatty acid uptake in the intestine in healthy middle-aged men, providing an additional mechanism by which exercise training can improve whole body metabolism.

  2. Metabolic and hormonal responses to isoenergetic high-intensity interval exercise and continuous moderate-intensity exercise.

    Science.gov (United States)

    Peake, Jonathan M; Tan, Sok Joo; Markworth, James F; Broadbent, James A; Skinner, Tina L; Cameron-Smith, David

    2014-10-01

    This study investigated the effects of high-intensity interval training (HIIT) vs. work-matched moderate-intensity continuous exercise (MOD) on metabolism and counterregulatory stress hormones. In a randomized and counterbalanced order, 10 well-trained male cyclists and triathletes completed a HIIT session [81.6 ± 3.7% maximum oxygen consumption (V̇o2 max); 72.0 ± 3.2% peak power output; 792 ± 95 kJ] and a MOD session (66.7 ± 3.5% V̇o2 max; 48.5 ± 3.1% peak power output; 797 ± 95 kJ). Blood samples were collected before, immediately after, and 1 and 2 h postexercise. Carbohydrate oxidation was higher (P = 0.037; 20%), whereas fat oxidation was lower (P = 0.037; -47%) during HIIT vs. MOD. Immediately after exercise, plasma glucose (P = 0.024; 20%) and lactate (P HIIT vs. MOD, whereas total serum free fatty acid concentration was not significantly different (P = 0.33). Targeted gas chromatography-mass spectromtery metabolomics analysis identified and quantified 49 metabolites in plasma, among which 11 changed after both HIIT and MOD, 13 changed only after HIIT, and 5 changed only after MOD. Notable changes included substantial increases in tricarboxylic acid intermediates and monounsaturated fatty acids after HIIT and marked decreases in amino acids during recovery from both trials. Plasma adrenocorticotrophic hormone (P = 0.019), cortisol (P HIIT. Plasma norepinephrine (P = 0.11) and interleukin-6 (P = 0.20) immediately after exercise were not significantly different between trials. Plasma insulin decreased during recovery from both HIIT and MOD (P HIIT vs. MOD and highlight the value of targeted metabolomic analysis to provide more detailed insights into the metabolic demands of exercise.

  3. High-Intensity Interval Training as an Efficacious Alternative to Moderate-Intensity Continuous Training for Adults with Prediabetes

    Directory of Open Access Journals (Sweden)

    Mary E. Jung

    2015-01-01

    Full Text Available Aims. High-intensity interval training (HIIT leads to improvements in various markers of cardiometabolic health but adherence to HIIT following a supervised laboratory intervention has yet to be tested. We compared self-report and objective measures of physical activity after one month of independent exercise in individuals with prediabetes who were randomized to HIIT (n=15 or traditional moderate-intensity continuous training (MICT, n=17. Method. After completing 10 sessions of supervised training participants were asked to perform HIIT or MICT three times per week for four weeks. Results. Individuals in HIIT (89 ± 11% adhered to their prescribed protocol to a greater extent than individuals in MICT (71 ± 31% as determined by training logs completed over one-month follow-up (P = 0.05, Cohen’s d = 0.75. Minutes spent in vigorous physical activity per week measured by accelerometer were higher in HIIT (24 ± 18 as compared to MICT (11 ± 10 at one-month follow-up (P = 0.049, Cohen’s d = 0.92. Cardiorespiratory fitness and systolic blood pressure assessed at one-month follow-up were equally improved (P’s < 0.05. Conclusions. This study provides preliminary evidence that individuals with prediabetes can adhere to HIIT over the short-term and do so at a level that is greater than MICT.

  4. Simultaneous observation of sporadic E with a rapid-run ionosonde and VHF coherent backscatter radar

    Directory of Open Access Journals (Sweden)

    T. Maruyama

    2006-03-01

    Full Text Available During the SEEK 2 rocket campaign, ionograms were recorded every minute at the Yamagawa Radio Observatory at about 90km west of the region monitored by a VHF (very high frequency coherent backscatter radar. Sporadic E-layer parameters, which include the critical (foEs and blanketing (fbEs frequencies, the layer height (h'Es, and the width of the range spread of sporadic E-traces, were compared with RTI (range-time-intensity plots of VHF quasi-periodic (QP and continuous coherent backscatter echoes. A close relationship was found between the appearance of QP echoes in the RTI plots and the level of spatial inhomogeneity in sporadic E plasma, signified here by the difference between foEs and fbEs. During QP echo events, foEs increased while fbEs decreased, so that the difference foEs-fbEs was enhanced, indicating the development of strong spatial structuring in electron density within a sporadic E-layer. On the other hand, increases in sporadic E range spreading also correlated with the occurrence of QP echoes but the degree of correlation varied from event to event. Continuous radar echoes were observed in association with low altitude sporadic E-layers, located well below 100 km and at times as low as 90 km. During the continuous echo events, both foEs and fbEs were less variable, and the difference foEs-fbEs was small and not as dynamic as in the QP echoes. On the other hand, the Es-layer spread intensified during continuous echoes, which means that some patchiness or corrugation in those low altitude layers is also necessary for the continuous backscatter echoes to take place.

  5. Backscattering characteristics Analyses of winter wheat covered area and Drought Monitoring Based on active microwave

    Science.gov (United States)

    Zhang, C., Sr.; Li, L.

    2015-12-01

    The advantage of active microwave remote sensing on the sensitivity of polarization characteristic, backscatter intensity and phase characteristics to soil moisture demonstrates its potential to map and monitor relative soil moisture changes and drought information with high spatial resolution. However, the existence of soil surface condition and vegetation effects confounds the retrieval of soil moisture from active microwave, and therefore limits its applications on soil moisture retrieval and drought monitoring. To research how to reduce the effect of soil roughness and wheat cover with multi- incident angles and multi polarization active microwave remote sensing data, MIMICS and AIEM models were used to simulate the backscattering coefficient of winter wheat covered field. The interaction between winter wheat at main growth stages and microwave was analyzed. The effects of surface roughness and physical parameters of wheat on the backscattering characteristics and the variation of different incident angles and different polarization conditions are simulated and analyzed emphatically. Then scattering coefficient information of winter wheat covered area at different wheat growth stage was measured with a C band ground-based scattering meter. At the same time, biomass, leaf area index and soil rough degree, soil water content and other related parameters are collected. After comparing and analyzing the measured data and the simulated data at different incident angles and different polarization modes, we propose an approach of using multi polarization and multi angle data to eliminate the soil roughness and wheat vegetation effects and performing the inversion of soil moisture. Using the Radarsat2 satellite SAR data and ground-based scatter data gotten at the same period in 2012, soil moisture information of greater area is obtained, and then the drought information is obtained, which is consistent with the measured results.

  6. Hot electron generation and energy coupling in planar experiments with shock ignition high intensity lasers

    Science.gov (United States)

    Wei, M. S.; Krauland, C.; Alexander, N.; Zhang, S.; Peebles, J.; Beg, F. N.; Theobald, W.; Borwick, E.; Ren, C.; Yan, R.; Haberberger, D.; Betti, R.; Campbell, E. M.

    2016-10-01

    Hot electrons produced in nonlinear laser plasma interactions are critical issues for shock ignition (SI) laser fusion. We conducted planar target experiments to characterize hot electron and energy coupling using the high energy OMEGA EP laser system at SI high intensities. Targets were multilayered foils consisting of an ablator (either plastic or lithium) and a Cu layer to facilitate hot electron detection via fluorescence and bremsstrahlung measurements. The target was first irradiated by multi-kJ, low-intensity UV beams to produce a SI-relevant mm-scale hot ( 1 keV) preformed plasma. The main interaction pulse, either a kJ 1-ns UV pulse with intensity 1.6x1016 Wcm-2 or a kJ 0.1-ns IR pulse with intensity up to 2x1017 Wcm-2was injected at varied timing delays. The high intensity IR beam was found to strongly interact with underdense plasmas breaking into many filaments near the quarter critical density region followed by propagation of those filaments to critical density, producing hot electrons with Thot 70 keV in a well-contained beam. While the high intensity UV beam showed poor energy coupling. Details of the experiments and the complementary PIC modeling results will be presented. Work supported by U.S. DOE under contracts DE-NA0002730 (NLUF) and DE-SC0014666 (HEDLP).

  7. Production of Medical Radioisotopes with High Specific Activity in Photonuclear Reactions with $\\gamma$ Beams of High Intensity and Large Brilliance

    CERN Document Server

    Habs, D

    2010-01-01

    We study the production of radioisotopes for nuclear medicine in $(\\gamma,x{\\rm n}+y{\\rm p})$ photonuclear reactions or ($\\gamma,\\gamma'$) photoexcitation reactions with high flux [($10^{13}-10^{15}$)$\\gamma$/s], small diameter $\\sim (100 \\, \\mu$m$)^2$ and small band width ($\\Delta E/E \\approx 10^{-3}-10^{-4}$) $\\gamma$ beams produced by Compton back-scattering of laser light from relativistic brilliant electron beams. We compare them to (ion,$x$n$ + y$p) reactions with (ion=p,d,$\\alpha$) from particle accelerators like cyclotrons and (n,$\\gamma$) or (n,f) reactions from nuclear reactors. For photonuclear reactions with a narrow $\\gamma$ beam the energy deposition in the target can be managed by using a stack of thin target foils or wires, hence avoiding direct stopping of the Compton and pair electrons (positrons). $(\\gamma,\\gamma')$ isomer production via specially selected $\\gamma$ cascades allows to produce high specific activity in multiple excitations, where no back-pumping of the isomer to the ground st...

  8. Tracking California seafloor seeps with bathymetry, backscatter and ROVs

    Science.gov (United States)

    Orange, Daniel L.; Yun, Janet; Maher, Norman; Barry, James; Greene, Gary

    2002-11-01

    The California (USA) margin includes two different tectonic regimes: subduction north of the Mendocino Triple Junction and translation south. Both margins include seeps, and their distribution can be inferred using seafloor bathymetry and backscatter as well as subsurface seismic data. Anomalous bathymetric and backscatter features related to fluid expulsion include headless submarine canyons, fault zones, anticlines, pockmarks, and mud volcanoes. Anomalous backscatter may be caused by authigenic carbonate (related to the bacterial oxidation of methane) or cold seep clams—both have an impedance and roughness that may be higher than the surrounding seafloor. Remote-operated vehicle (ROV) dives to such suspect seep sites document the presence of extensive authigenic carbonate, areally restricted cold seep communities, carpets of chemoautotrophic bacteria, and bubbling gas. Our operations in the Monterey Bay, on the translational California margin, and the Eel River basin, on the convergent margin, indicate that bathymetric and backscatter maps of the seafloor, if sufficiently high resolution, can be used to map seep sites, and that the distribution of such seeps can be used to constrain subsurface conduits of fluid flow. ROVs, due to their combination of visualization, propulsion, manipulation, sonar, and navigation, provide an excellent platform for ground-truthing, mapping, and sampling seafloor seeps.

  9. Anthropometric, Sprint, and High-Intensity Running Profiles of English Academy Rugby Union Players by Position.

    Science.gov (United States)

    Darrall-Jones, Joshua D; Jones, Ben; Till, Kevin

    2016-05-01

    The purpose of this study was to evaluate the anthropometric, sprint, and high-intensity running profiles of English academy rugby union players by playing positions, and to investigate the relationships between anthropometric, sprint, and high-intensity running characteristics. Data were collected from 67 academy players after the off-season period and consisted of anthropometric (height, body mass, sum of 8 skinfolds [∑SF]), 40-m linear sprint (5-, 10-, 20-, and 40-m splits), the Yo-Yo intermittent recovery test level 1 (Yo-Yo IRTL-1), and the 30-15 intermittent fitness test (30-15 IFT). Forwards displayed greater stature, body mass, and ∑SF; sprint times and sprint momentum, with lower high-intensity running ability and sprint velocities than backs. Comparisons between age categories demonstrated body mass and sprint momentum to have the largest differences at consecutive age categories for forwards and backs; whereas 20-40-m sprint velocity was discriminate for forwards between under 16s, 18s, and 21s. Relationships between anthropometric, sprint velocity, momentum, and high-intensity running ability demonstrated body mass to negatively impact on sprint velocity (10 m; r = -0.34 to -0.46) and positively affect sprint momentum (e.g., 5 m; r = 0.85-0.93), with large to very large negative relationships with the Yo-Yo IRTL-1 (r = -0.65 to -0.74) and 30-15 IFT (r = -0.59 to -0.79). These findings suggest that there are distinct anthropometric, sprint, and high-intensity running ability differences between and within positions in junior rugby union players. The development of sprint and high-intensity running ability may be impacted by continued increases in body mass as there seems to be a trade-off between momentum, velocity, and the ability to complete high-intensity running.

  10. Effect of moderate- and high-intensity acute exercise on appetite in obese individuals

    DEFF Research Database (Denmark)

    Martins, Catia; Stensvold, Dorthe; Finlayson, Graham

    2015-01-01

    cycling (MICC) or short-duration HIIC (S-HIIC) (125 kcal) and a resting control condition on the appetite hormone responses, subjective feelings of appetite, energy intake (EI), and food reward in overweight/obese individuals. METHODS: This study is a randomized crossover study on 12 overweight/obese......, hunger or fullness ratings, EI, or food reward. CONCLUSIONS: Our findings suggest that, in overweight/obese individuals, isocaloric bouts of moderate- or high-intensity exercise lead to a similar appetite response. This strengthens previous findings in normal-weight individuals that acute exercise, even......PURPOSE: The effect of acute exercise, and exercise intensity, on appetite control in obese individuals requires further study. The aim of this study was to compare the effects of acute isocaloric bouts (250 kcal) of high-intensity intermittent cycling (HIIC) and moderate-intensity continuous...

  11. Impact of the dipole-moment representation on the intensity of high overtones

    Science.gov (United States)

    Medvedev, Emile S.; Meshkov, Vladimir V.; Stolyarov, Andrey V.; Ushakov, Vladimir G.; Gordon, Iouli E.

    2016-12-01

    Calculating intensities of ro-vibrational transitions is particularly challenging for transitions from a given vibrational state to all upper states up to the dissociation limit because their probabilities decrease exponentially with increasing Δn , the change in the vibrational quantum number. The experimental intensities available for low- Δn values are well reproduced by a variety of models but the models can greatly diverge in predicting the intensities of unobserved high-overtone transitions, the divergence rapidly increasing with the overtone number. In this paper, we investigate the impact of the dipole-moment function (DMF) representation on the high-overtone intensity simulation of the CO molecule. We tested various DMF forms including pointwise representation combined with cubic-spline interpolation, power and trigonometric expansions, and Padé approximants. Numerical calculations were performed with the highly accurate empirical potential-energy function (PEF) of Coxon and Hajigeorgiou (2004) using quadruple-precision arithmetic. Most calculated intensities fall off in the entire range of transitions according to the Normal Intensity Distribution Law (NIDL) (Medvedev, 2012). The slope of the NIDL trend line varies little between different analytical DMFs for a given PEF since the slope is basically associated with the PEF. Based on the NIDL, the limits within which the simulated intensities fall off up to the dissociation limit can be established. We claim that DMFs represented by analytical functions yield best results for all transitions. The pointwise functions (interpolated, in particular, by the conventional cubic splines) result in an unphysical flattening of the intensities at high- Δn transitions, Δn > 7 for CO.

  12. A novel biometric X-ray backscatter inspection of dangerous materials based on a lobster-eye objective

    Science.gov (United States)

    Xu, Jie; Wang, Xin; Mu, Baozhong; Zhan, Qi; Xie, Qing; Li, Yaran; Chen, Yifan; He, Yanan

    2016-10-01

    In order to counter drug-related crimes effectively, and to safeguard homeland security as well as public safety, it is important to inspect drugs, explosives and other contraband quickly and accurately from the express mail system, luggage, vehicles and other objects. In this paper, we discuss X-ray backscatter inspection system based on a novel lobster-eye X-ray objective, which is an effective inspection technology for drugs, explosives and other contraband inspection. Low atomic number materials, such as drugs and explosives, leads to strong Compton scattering after irradiated by X-ray, which is much stronger than high atomic number material, such as common metals, etc. By detecting the intensity of scattering signals, it is possible to distinguish between organics and inorganics. The lobster-eye X-ray optical system imitates the reflective eyes of lobsters, which field of view can be made as large as desired and it is practical to achieve spatial resolution of several millimeters for finite distance detection. A novel lobster-eye X-ray objective is designed based on modifying Schmidt geometry by using multi-lens structure, so as to reduce the difference of resolution between the horizontal and vertical directions. The demonstration experiments of X-ray backscattering imaging were carried out. A suitcase, a wooden box and a tire with several typical samples hidden in them were imaged by the X-ray backscattering inspection system based on a lobster-eye X-ray objective. The results show that this X-ray backscattering inspection system can get a resolution of less than five millimeters under the FOV of more than two hundred millimeters with 0.5 meter object distance, which can still be improved.

  13. Nutritional strategies to support adaptation to high-intensity interval training in team sports.

    Science.gov (United States)

    Gibala, Martin J

    2013-01-01

    Team sports are characterized by intermittent high-intensity activity patterns. Typically, play consists of short periods of very intense or all-out efforts interspersed with longer periods of low-intensity activity. Fatigue is a complex, multi-factorial process, but intense intermittent exercise performance can potentially be limited by reduced availability of substrates stored in skeletal muscle and/or metabolic by-products associated with fuel breakdown. High-intensity interval training (HIT) has been shown to induce adaptations in skeletal muscle that enhance the capacity for both oxidative and non-oxidative metabolism. Nutrient availability is a potent modulator of many acute physiological responses to exercise, including various molecular signaling pathways that are believed to regulate cellular adaptation to training. Several nutritional strategies have also been reported to acutely alter metabolism and enhance intermittent high-intensity exercise performance. However, relatively little is known regarding the effect of chronic interventions, and whether supplementation over a period of weeks or months augments HIT-induced physiological remodeling and promotes greater performance adaptations. Theoretically, a nutritional intervention could augment HIT adaptation by improving energy metabolism during exercise, which could facilitate greater total work and an enhanced chronic training stimulus, or promoting some aspect of the adaptive response during recovery, which could lead to enhanced physiological adaptations over time.

  14. High signal intensity of the septum pellucidum at MR imaging; Significance in hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Kim, Eun Ha; Chung, Chun Phil; Kim, Chang Soo [Maryknoll Hospital, Pusan (Korea, Republic of)

    1994-05-15

    To evaluate the significance of high signal intensity of the septum pellucidum in hydrocephalus on proton density-weighted brain MR images. Authors reviewed the MR images of 418 cases of patients with normal (175 case), hydrocephalic(35 cases), atrophic(58 cases), and other groups(150 cases) retrospectively. We analyzed the signal intensity of the septum pellucidum in the normal group and the incidences of high signal intensities of periventricular area of frontal horn of lateral ventricle(area 1), periventricular area except area 1 (area 2), callososeptal area(area 3), and septum pellucidum(area 4) in the normal and abnormal groups. In the normal group, the septum pellucidum was isointense to the head of caudate nucleus on proton density-weighted image. High signal intensity of the septum pellucidum was seen in 31 cases (22 cases of hydrocephalus, 5 cases of brain atrophy, and 4 cases of others), and showed high specificity(91.4%) for hydrocephalus in spite of low sensitivity(62.9%), as compared with periventricular hyperintensities of other areas. High signal intensity of the septum pellucidum on proton density- weighted image may be caused by transependymal CSF migration in the patients with hydrocephalus, and considered as an additional finding of hydrocephalus in the cases of ventriculomegaly.

  15. The Effects of High-Intensity versus Low-Intensity Resistance Training on Leg Extensor Power and Recovery of Knee Function after ACL-Reconstruction

    DEFF Research Database (Denmark)

    Bieler, Theresa; Sobol, Nanna Aue; Andersen, Lars L

    2014-01-01

    OBJECTIVE: Persistent weakness is a common problem after anterior cruciate ligament- (ACL-) reconstruction. This study investigated the effects of high-intensity (HRT) versus low-intensity (LRT) resistance training on leg extensor power and recovery of knee function after ACL-reconstruction. METH...

  16. High-Intensity Intermittent Swimming Improves Cardiovascular Health Status for Women with Mild Hypertension

    Directory of Open Access Journals (Sweden)

    Magni Mohr

    2014-01-01

    Full Text Available To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n=21; HIT, moderate-intensity (n=21; MOD, and control groups (n=20; CON. HIT performed 6–10 × 30 s all-out swimming interspersed by 2 min recovery and MOD swam continuously for 1 h at moderate intensity for a 15-week period completing in total 44±1 and 43±1 sessions, respectively. In CON, all measured variables were similar before and after the intervention period. Systolic BP decreased (P<0.05 by 6±1 and 4±1 mmHg in HIT and MOD; respectively. Resting heart rate declined (P<0.05 by 5±1 bpm both in HIT and MOD, fat mass decreased (P<0.05 by 1.1±0.2 and 2.2±0.3 kg, respectively, while the blood lipid profile was unaltered. In HIT and MOD, performance improved (P<0.05 for a maximal 10 min swim (13±3% and 22±3%, interval swimming (23±3% and 8±3%, and Yo-Yo IE1 running performance (58±5% and 45±4%. In conclusion, high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group.

  17. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Directory of Open Access Journals (Sweden)

    Thomas L. Stöggl

    2017-08-01

    Full Text Available The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR in well-trained endurance athletes.Methods: Thirty-six male (n = 33 and female (n = 3 runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak: 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT. A maximal anaerobic running/cycling test (MART/MACT was performed prior to and following a 9-week training period.Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001 and peak lactate (P = 0.001 during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1 was changed (P > 0.05. Acute HRR was improved in HIIT (11.2%, P = 0.002 and POL (7.9%, P = 0.023 with no change in the HVLIT oriented control group.Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT had no effect on any performance or HRR outcomes.

  18. Dynamics of cavitation clouds within a high-intensity focused ultrasonic beam

    NARCIS (Netherlands)

    Lu, Yuan; Katz, Joseph; Prosperetti, Andrea

    2013-01-01

    In this experimental study, we generate a 500 kHz high-intensity focused ultrasonic beam, with pressure amplitude in the focal zone of up to 1.9 MPa, in initially quiescent water. The resulting pressure field and behavior of the cavitation bubbles are measured using high-speed digital in-line hologr

  19. Optimizing Planning and Delivery of High-Precision Robotic Radiotherapy and Intensity-Modulated Proton Therapy

    NARCIS (Netherlands)

    S. van de Water (Steven)

    2015-01-01

    markdownabstract__Abstract__ High-precision robotic radiotherapy and intensity-modulated proton therapy (IMPT) are two relatively new radiotherapy techniques that particularly aim at a highly localized delivery of a curative dose to the tumor, while achieving excellent sparing of the surrounding

  20. A High School Intensive Summer Mandarin Course: Program Model and Learner Outcomes

    Science.gov (United States)

    Xu, Xiaoqiu; Padilla, Amado M.; Silva, Duarte; Masuda, Norman

    2012-01-01

    This article describes a STARTALK intensive summer high school Mandarin language and culture program that was conducted for three summers. Participants across the three years included 40 Mandarin Level II and 53 Mandarin Level III high school students. Quantitative and qualitative data are presented to show the effectiveness of the program.…

  1. Optimizing Planning and Delivery of High-Precision Robotic Radiotherapy and Intensity-Modulated Proton Therapy

    NARCIS (Netherlands)

    S. van de Water (Steven)

    2015-01-01

    markdownabstract__Abstract__ High-precision robotic radiotherapy and intensity-modulated proton therapy (IMPT) are two relatively new radiotherapy techniques that particularly aim at a highly localized delivery of a curative dose to the tumor, while achieving excellent sparing of the surrounding he

  2. Is Moderate Intensity Exercise Training Combined with High Intensity Interval Training More Effective at Improving Cardiorespiratory Fitness than Moderate Intensity Exercise Training Alone?

    Directory of Open Access Journals (Sweden)

    Brendon H. Roxburgh, Paul B. Nolan, Ryan M. Weatherwax, Lance C. Dalleck

    2014-09-01

    Full Text Available The purpose of this study was to compare the effectiveness of either continuous moderate intensity exercise training (CMIET alone vs. CMIET combined with a single weekly bout of high intensity interval training (HIIT on cardiorespiratory fitness. Twenty nine sedentary participants (36.3 ± 6.9 yrs at moderate risk of cardiovascular disease were recruited for 12 weeks of exercise training on a treadmill and cycle ergometer. Participants were randomised into three groups: CMIET + HIIT (n = 7; 8-12 x 60 sec at 100% VO2max, 150 sec active recovery, CMIET (n = 6; 30 min at 45-60% oxygen consumption reserve (VO2R and a sedentary control group (n = 7. Participants in the CMIET + HIIT group performed a single weekly bout of HIIT and four weekly sessions of CMIET, whilst the CMIET group performed five weekly CMIET sessions. Probabilistic magnitude-based inferences were determined to assess the likelihood that the true value of the effect represents substantial change. Relative VO2max increased by 10.1% (benefit possible relative to control in in the CMIET + HIIT group (32.7 ± 9.2 to 36.0 ± 11.5 mL·kg-1·min-1 and 3.9% (benefit possible relative to control in the CMIET group (33.2 ± 4.0 to 34.5 ± 6.1 mL·kg-1·min-1, whilst there was a 5.7% decrease in the control group (30.0 ± 4.6 to 28.3 ± 6.5 mL·kg-1·min-1. It was ‘unclear’ if a clinically significant difference existed between the effect of CMIET + HIIT and CMIET on the change in VO2max. Both exercising groups showed clinically meaningful improvements in VO2max. Nevertheless, it remains ‘unclear’ whether one type of exercise training regimen elicits a superior improvement in cardiorespiratory fitness relative to its counterpart.

  3. High Intensity Interval- vs Moderate Intensity- Training for Improving Cardiometabolic Health in Overweight or Obese Males: A Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Gordon Fisher

    Full Text Available To compare the effects of six weeks of high intensity interval training (HIIT vs continuous moderate intensity training (MIT for improving body composition, insulin sensitivity (SI, blood pressure, blood lipids, and cardiovascular fitness in a cohort of sedentary overweight or obese young men. We hypothesized that HIIT would result in similar improvements in body composition, cardiovascular fitness, blood lipids, and SI as compared to the MIT group, despite requiring only one hour of activity per week compared to five hours per week for the MIT group.28 sedentary overweight or obese men (age, 20 ± 1.5 years, body mass index 29.5 ± 3.3 kg/m2 participated in a six week exercise treatment. Participants were randomly assigned to HIIT or MIT and evaluated at baseline and post-training. DXA was used to assess body composition, graded treadmill exercise test to measure cardiovascular fitness, oral glucose tolerance to measure SI, nuclear magnetic resonance spectroscopy to assess lipoprotein particles, and automatic auscultation to measure blood pressure.A greater improvement in VO2peak was observed in MIT compared to HIIT (11.1% vs 2.83%, P = 0.0185 in the complete-case analysis. No differences were seen in the intention to treat analysis, and no other group differences were observed. Both exercise conditions were associated with temporal improvements in % body fat, total cholesterol, medium VLDL, medium HDL, triglycerides, SI, and VO2peak (P < 0.05.Participation in HIIT or MIT exercise training displayed: 1 improved SI, 2 reduced blood lipids, 3 decreased % body fat, and 4 improved cardiovascular fitness. While both exercise groups led to similar improvements for most cardiometabolic risk factors assessed, MIT led to a greater improvement in overall cardiovascular fitness. Overall, these observations suggest that a relatively short duration of either HIIT or MIT training may improve cardiometabolic risk factors in previously sedentary overweight or

  4. High Intensity Interval- vs Moderate Intensity- Training for Improving Cardiometabolic Health in Overweight or Obese Males: A Randomized Controlled Trial.

    Science.gov (United States)

    Fisher, Gordon; Brown, Andrew W; Bohan Brown, Michelle M; Alcorn, Amy; Noles, Corey; Winwood, Leah; Resuehr, Holly; George, Brandon; Jeansonne, Madeline M; Allison, David B

    2015-01-01

    To compare the effects of six weeks of high intensity interval training (HIIT) vs continuous moderate intensity training (MIT) for improving body composition, insulin sensitivity (SI), blood pressure, blood lipids, and cardiovascular fitness in a cohort of sedentary overweight or obese young men. We hypothesized that HIIT would result in similar improvements in body composition, cardiovascular fitness, blood lipids, and SI as compared to the MIT group, despite requiring only one hour of activity per week compared to five hours per week for the MIT group. 28 sedentary overweight or obese men (age, 20 ± 1.5 years, body mass index 29.5 ± 3.3 kg/m2) participated in a six week exercise treatment. Participants were randomly assigned to HIIT or MIT and evaluated at baseline and post-training. DXA was used to assess body composition, graded treadmill exercise test to measure cardiovascular fitness, oral glucose tolerance to measure SI, nuclear magnetic resonance spectroscopy to assess lipoprotein particles, and automatic auscultation to measure blood pressure. A greater improvement in VO2peak was observed in MIT compared to HIIT (11.1% vs 2.83%, P = 0.0185) in the complete-case analysis. No differences were seen in the intention to treat analysis, and no other group differences were observed. Both exercise conditions were associated with temporal improvements in % body fat, total cholesterol, medium VLDL, medium HDL, triglycerides, SI, and VO2peak (P training displayed: 1) improved SI, 2) reduced blood lipids, 3) decreased % body fat, and 4) improved cardiovascular fitness. While both exercise groups led to similar improvements for most cardiometabolic risk factors assessed, MIT led to a greater improvement in overall cardiovascular fitness. Overall, these observations suggest that a relatively short duration of either HIIT or MIT training may improve cardiometabolic risk factors in previously sedentary overweight or obese young men, with no clear advantage between these

  5. Meeting standards of high-quality intensive care unit palliative care: Clinical performance and predictors

    Science.gov (United States)

    Penrod, Joan D.; Pronovost, Peter J.; Livote, Elayne E.; Puntillo, Kathleen A.; Walker, Amy S.; Wallenstein, Sylvan; Mercado, Alice F.; Swoboda, Sandra M.; Ilaoa, Debra; Thompson, David A.; Nelson, Judith E.

    2012-01-01

    Objectives High-quality care for intensive care unit patients and families includes palliative care. To promote performance improvement, the Agency for Healthcare Research and Quality’s National Quality Measures Clearinghouse identified nine evidence-based processes of intensive care unit palliative care (Care and Communication Bundle) that are measured through review of medical record documentation. We conducted this study to examine how frequently the Care and Communication Bundle processes were performed in diverse intensive care units and to understand patient factors that are associated with such performance. Design Prospective, multisite, observational study of performance of key intensive care unit palliative care processes. Settings A surgical intensive care unit and a medical intensive care unit in two different large academic health centers and a medical-surgical intensive care unit in a medium-sized community hospital. Patients Consecutive adult patients with length of intensive care unit stay ≥5 days. Interventions None. Measurements and Main Results Between November 2007 and December 2009, we measured performance by specified day after intensive care unit admission on nine care process measures: identify medical decision-maker, advance directive and resuscitation preference, distribute family information leaflet, assess and manage pain, offer social work and spiritual support, and conduct interdisciplinary family meeting. Multivariable regression analysis was used to determine predictors of performance of five care processes. We enrolled 518 (94.9%) patients and 336 (83.6%) family members. Performances on pain assessment and management measures were high. In contrast, interdisciplinary family meetings were documented for <20% of patients by intensive care unit day 5. Performance on other measures ranged from 8% to 43%, with substantial variation across and within sites. Chronic comorbidity burden and site were the most consistent predictors of care

  6. High-intensity interval training and athletic performance in Taekwondo athletes.

    Science.gov (United States)

    Monks, Lynne; Seo, Myong-Won; Kim, Hyun-Bae; Jung, Hyun C; Song, Jong K

    2017-10-01

    The purpose of this study was to determine the effects of high-intensity interval training (HIIT) on athletic performance in Taekwondo athletes. Thirty-three male and female collegiate Taekwondo athletes were randomly divided into a HIIT group (N.=16) or a high-intensity continuous running (HICR) group (N.=17). The HIIT group undertook training of high-intensity sprints interspersed with active rest periods whilst the HICR group participated in high-intensity running for a continuous period. Both groups completed 11 sessions over 4 weeks. Physique, body composition, Wingate anaerobic test and VO2max test were measured. The vertical jump test, agility T-test and sit-ups were used to assess physical fitness. Repeated measures ANCOVAs with sex as a covariate were applied and significant level was set at 0.05. Following 11 sessions of training, significant improvements in anaerobic peak power (PTaekwondo competition performance in collegiate Taekwondo athletes. This could inform the future planning of Taekwondo athletes' pre-competition training, specifically the influence of training intensity on anaerobic capacity.

  7. Warm-up strategy and high-intensity endurance performance in trained cyclists

    DEFF Research Database (Denmark)

    Christensen, Peter Møller; Bangsbo, Jens

    2015-01-01

    PURPOSE: To evaluate the influence of warm-up exercise intensity and subsequent recovery on intense endurance performance, selected blood variables and the VO2 response. METHODS: Twelve highly trained male cyclists (VO2-max: 72.4±8.0·mL/min/kg, incremental-test peak power output (iPPO): 432±31 W......; means±SD) performed three warm-up strategies lasting 20 min before a 4-min maximal performance test (PT). Strategies consisted of moderate intensity exercise (50%iPPO) followed by 6 min of recovery (MOD6) or progressive-high intensity exercise (10-100%iPPO and 2x20-s sprints) followed by recovery for 6...... to HI20 (7.85±0.82 L; P=0.008) and MOD6 (7.90±0.74 L; P=0.012). CONCLUSIONS: Warm-up exercise including race-pace and sprint intervals combined with short recovery can reduce subsequent performance in a 4-min maximal test in highly trained cyclists. Thus, a reduced time at high exercise intensity...

  8. Study of ultra-high gradient wakefield excitation by intense ultrashort laser pulses in plasma

    Science.gov (United States)

    Kotaki, Hideyuki; Kando, Masaki; Oketa, Takatsugu; Masuda, Shinichi; Koga, James K.; Kondo, Shuji; Kanazawa, Shuhei; Yokoyama, Takashi; Matoba, Toru; Nakajima, Kazuhisa

    2002-10-01

    We investigate a laser wakefield excited by intense laser pulses, and the possibility of generating an intense bright electron source by an intense laser pulse. The coherent wakefield excited by 2 TW, 50 fs laser pulses in a gas-jet plasma around 1018 cm-3 is measured with a time-resolved frequency domain interferometer (FDI). The results show an accelerating wakefield excitation of 20 GeV/m with good coherency. This is the first time-resolved measurement of laser wakefield excitation in a gas-jet plasma. The experimental results agree with the simulation results and linear theory. The pump-probe interferometer system of FDI will be modified to the optical injection system as a relativistic electron beam injector. In 1D particle in cell simulation we obtain results of high quality intense electron beam generation.

  9. High-quality binary fringe generation via joint optimization on intensity and phase

    Science.gov (United States)

    Xiao, Yi; Li, Youfu

    2017-10-01

    There have been active studies on optimized dithering techniques to improve 3D shape measurement quality with defocused projectors. These techniques optimize the fringe quality in either phase domain or intensity domain according to their objective functions. Phase based optimization is direct and effective, but is sensitive to projector defocus levels. Intensity based optimization is robust to projector defocus levels, but it does not fully improve the phase quality. This paper presents a joint optimization technique to combine the merits of both the intensity and phase based optimization, which includes a pre-intensity optimization and a further optimization based on the synthesized error function. Then this technique is implemented in two frameworks, the whole-fringe optimization and the best-patch optimization, to generate binary fringe patterns. Both simulations and experiments show that the proposed technique can generate binary fringe patterns with high phase quality and robustness to projector defocus levels.

  10. Low-intensity red and infrared laser effects at high fluences on Escherichia coli cultures

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, L.L.; Campos, V.M.A.; Magalhaes, L.A.G. [Instituto de Biologia Roberto Alcantara Gomes, Rio de Janeiro, RJ (Brazil). Departamento de Biofisica e Biometria; Paoli, F. [Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil). Departamento de Morfologia; Fonseca, A.S., E-mail: adnfonseca@ig.com.br [Universidade Federal do Estado do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Departamento de Ciencias Fisiologicas

    2015-10-15

    Semiconductor laser devices are readily available and practical radiation sources providing wavelength tenability and high monochromaticity. Low-intensity red and near-infrared lasers are considered safe for use in clinical applications. However, adverse effects can occur via free radical generation, and the biological effects of these lasers from unusually high fluences or high doses have not yet been evaluated. Here, we evaluated the survival, filamentation induction and morphology of Escherichia coli cells deficient in repair of oxidative DNA lesions when exposed to low-intensity red and infrared lasers at unusually high fluences. Cultures of wild-type (AB1157), endonuclease III-deficient (JW1625-1), and endonuclease IV-deficient (JW2146-1) E. coli, in exponential and stationary growth phases, were exposed to red and infrared lasers (0, 250, 500, and 1000 J/cm{sup 2}) to evaluate their survival rates, filamentation phenotype induction and cell morphologies. The results showed that low-intensity red and infrared lasers at high fluences are lethal, induce a filamentation phenotype, and alter the morphology of the E. coli cells. Low-intensity red and infrared lasers have potential to induce adverse effects on cells, whether used at unusually high fluences, or at high doses. Hence, there is a need to reinforce the importance of accurate dosimetry in therapeutic protocols. (author)

  11. High-intensity exercise training produces morphological and biochemical changes in adrenal gland of mice.

    Science.gov (United States)

    Bartalucci, A; Ferrucci, M; Fulceri, F; Lazzeri, G; Lenzi, P; Toti, L; Serpiello, F R; La Torre, A; Gesi, M

    2012-06-01

    The effects of training are dependent on complex, adaptive changes which are induced by acute physical exercise at different levels. In particular, evidence shows that the hypothalamus-pituitary-adrenocortical axis, as well as the sympatho-adrenomedullary system, is mainly involved in mediating the physiological effects of physical exercise. The aim of the present study was to investigate, through a morphological and biochemical approach, the effects of training on the adrenal gland of mice, following two different protocols consisting of either low- or high-intensity training. Mice were run daily on a motorised treadmill for 8 weeks, at a velocity corresponding to 60% (low-intensity exercise) or 90% (high-intensity exercise) of the maximal running velocity previously determined by an incremental exercise test. We found that physical exercise produced an increase in the adrenal gland size compared with the control (sedentary) mice. The increase was 31.04% for mice that underwent high-intensity exercise and 10.08% for mice that underwent low intensity exercise, and this appeared to be the result of an increase in the area of both the adrenal cortex and adrenal medulla. Morphological analysis of the adrenal cortex showed that both types of exercise produced an increase in cytoplasmic vacuoles in steroidogenic cells, appearing more abundant after high-intensity exercise. No change was found in the reticulate zone. In the adrenal medulla, despite the absence of morphological changes, immunohistochemistry for tyrosine hydroxylase, dopamine β-hydroxylase and phenyl-ethanolamine-N-methyltransferase demonstrated an increased immunopositivity for these cathecolamine-synthesizing enzymes after intense exercise. These results were confirmed by immunoblot accompanied by densitometric analysis.

  12. Formation of Nanoscale Intermetallic Phases in Ni Surface Layer at High Intensity Implantation of Al Ions

    Institute of Scientific and Technical Information of China (English)

    I.A.Bozhko; S.V.Fortuna; I.A.Kurzina; I.B.Stepanov; E.V.Kozlov; Yu.P. Sharkeev

    2004-01-01

    The results of experimental study of nanoscale intermetallic formation in surface layer of a metal target at ion implantation are presented. To increase the thickness of the ion implanted surface layer the high intensive ion implantation is used. Compared with the ordinary ion implantation, the high intensive ion implantation allows a much thicker modified surface layer. Pure polycrystalline nickel was chosen as a target. Nickel samples were irradiated with Al ions on the vacuum-arc ion beam and plasma flow source "Raduga-5". It was shown that at the high intensity ion implantation the fine dispersed particles of Ni3Al, NiAl intermetallic compounds and solid solution Al in Ni are formed in the nickel surface layer of 200 nm and thicker. The formation of phases takes place in complete correspondence with the Ni-Al phase diagram.

  13. The high intensity solar cell - Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    This paper discusses the problems associated with conventional solar cells at high intensities and presents the design considerations and performance characteristics of the 'high intensity' (HI) solar cell which appears to eliminate the major problems. Test data obtained at greater than 250 AM1 suns gave a peak output power density of 2 W per sq cm at an efficiency exceeding 6% with an unoptimized cell operating at over 100 C. It appears that operation at 1000 AM1 suns at efficiencies greater than 10% is possible. At 1000 AM1 suns and 10% efficiency, the HI cell manufacturing cost is estimated to be $0.25/watt, with multi-megawatt annual production capability already existing within the industrial sector. A high intensity solar system was also analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency.

  14. The clinical study on high intensity zone of magnetic resonance imaging using Scolopendrid Aquacupuncture.

    Directory of Open Access Journals (Sweden)

    Jeong-a Lim

    2006-12-01

    Full Text Available Objective : This study was designed to find out the effect of scolopendrid aquacupuncture on low back pain with or without sciatica showing high intensity zone of magnetic resonance imaging. Methods : The 30 patients who had a diagnosis of high intensity zone by lumbar-MRI and admitted to Gwangju oriental medical hospital in wonkwang university from January 2005 to August 2004 were observed. The symptom of inpatients is low back pain with or without sciatica. We treated 30 patients by scolopendrid aquacupuncture besides the general conservative treatment of oriental medicine. Results and Conclusion : The scolopendrid aquacupuncture treatment led to improvement in the pain and symptom of disability as determined by all efficacy measures. After scolopendrid aquacupuncture treatment, there was improvement in VAS, ROM and SLRT. This results suggest that scolopendrid aquacupuncture is good method for treatment of low back pain with or without sciatica showing high intensity zone of magnetic resonance imaging.

  15. Changes in satellite cells in human skeletal muscle after a single bout of high intensity exercise

    DEFF Research Database (Denmark)

    Crameri, Regina M; Langberg, Henning; Magnusson, Peter

    2004-01-01

    desmin or dystrophin, were not observed, and hence did not appear to induce the expression of either N-CAM or FA1. We therefore propose that satellite cells can be induced to re-enter the cell growth cycle after a single bout of unaccustomed high intensity exercise. However, a single bout of exercise......No studies to date have reported activation of satellite cells in vivo in human muscle after a single bout of high intensity exercise. In this investigation, eight individuals performed a single bout of high intensity exercise with one leg, the contralateral leg being the control. A significant...... increase in mononuclear cells staining for the neural cell adhesion molecule (N-CAM) and fetal antigen 1 (FA1) were observed within the exercised human vastus lateralis muscle on days 4 and 8 post exercise. In addition, a significant increase in the concentration of the FA1 protein was determined...

  16. Repeated high-intensity exercise modulates Ca(2+) sensitivity of human skeletal muscle fibers

    DEFF Research Database (Denmark)

    Gejl, K D; Hvid, L G; Willis, S J;

    2016-01-01

    The effects of short-term high-intensity exercise on single fiber contractile function in humans are unknown. Therefore, the purposes of this study were: (a) to access the acute effects of repeated high-intensity exercise on human single muscle fiber contractile function; and (b) to examine whether...... the fourth sprint with respect to Ca(2+) sensitivity and maximal Ca(2+) -activated force. To investigate the oxidative effects of exercise on single fiber contractile function, a subset of fibers was incubated with dithiothreitol (DTT) before analysis. Ca(2+) sensitivity was enhanced by exercise in both MHC...... I (17%, P exercise. In conclusion, repeated high-intensity exercise increased Ca(2+) sensitivity in both MHC I and MHC II...

  17. The intensity dependence of surface recombination in high concentration solar cells with charge induced passivation

    Science.gov (United States)

    Gray, J. L.; Schwartz, R. J.; Lundstrom, M. S.; Nasby, R. D.

    High intensity solar cells which are designed to minimize series resistance and shadowing losses, frequently employ an illuminated surface which is relatively far removed from the collecting junctions. This requires that the surface be well passivated to minimize surface recombination. One technique frequently employed to minimize surface recombination is to incorporate a fixed charge in the passivating oxide. This work shows that at sufficiently high intensities the surface recombination can increase dramatically. This results in a reduction in the high intensity collection efficiency. A comparison of the collection efficiency of interdigitated back contact cells and etched multiple vertical junction cells is given which shows that EMVJ cells are less sensitive to this effect than IBC cells.

  18. High-intensity running in English FA Premier League soccer matches

    DEFF Research Database (Denmark)

    Bradley, Paul S.; Sheldon, William; Wooster, Blake

    2009-01-01

    The aims of this study were to (1) determine the activity profiles of a large sample of English FA Premier League soccer players and (2) examine high-intensity running during elite-standard soccer matches for players in various playing positions. Twenty-eight English FA Premier League games were.......01), attackers (2341 m, s=575, P game, high-intensity running distance was approximately 20% less than in the first 15-min period for wide midfielders (467 m, s=104 vs. 589 m, s=134, P ....01) and without ball possession (229 m, s=85 vs. 278 m, s=97, P game. Mean recovery time between very high-intensity running bouts was 72 s (s=28), with a 28% longer recovery time during the last 15 min than the first 15 min of the game (83 s, s=26 vs...

  19. Stimulated recombination of antiproton and positron with ultra-short ultra-high intensity laser pulse

    CERN Document Server

    Ryabinina, M V

    2003-01-01

    Ionization of hydrogen atom in the field of high-intense ultra-short femto-second laser pulse recently became the subject of comprehensive theoretical approaches. On the other hand, there exists experimental evidence that short electric pulses can effectively stimulate electron-proton (as well as antiproton-positron) recombination to high-level (Rydberg) state. In this paper we present the results of the theoretical estimations of antiproton-positron recombination cross-section in cold mixed plasmas in traps in the conditions of ATHENA/ATRAP experiments in CERN under the action of sub-fs laser pulse with TW intensity. (2 refs).

  20. Threshold Stress Intensity of Hydrogen-Induced Cracking and Stress Corrosion Cracking of High Strength Steel

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The threshold stress intensity of stress corrosion cracking (SCC) for 40CrMo steel in 3.5 % NaCl solution decreased exponentially with the increase of yield strength. The threshold stress intensity of hydrogen-induced cracking during dynamical charging for 40CrMo steel decreased linearly with the logarithm of the concentration of diffusible hydrogen. This equation was also applicable to SCC of high strength steel in aqueous solution. The critical hydrogen enrichment concentration necessary for SCC of high strength steel in water decreased exponentially with the increase of yield strength. Based on the results, the relationship between KISCC and σys could be deduced.

  1. Design concept of radiation control system for the high intensity proton accelerator facility

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Yukihiro; Ikeno, Koichi; Akiyama, Shigenori; Harada, Yasunori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-11-01

    Description is given for the characteristic radiation environment for the High Intensity Proton Accelerator Facility and the design concept of the radiation control system of it. The facility is a large scale accelerator complex consisting of high energy proton accelerators carrying the highest beam intensity in the world and the related experimental facilities and therefore provides various issues relevant to the radiation environment. The present report describes the specifications for the radiation control system for the facility, determined in consideration of these characteristics. (author)

  2. Rapid response of soil fungal communities to low and high intensity fire

    Science.gov (United States)

    Smith, Jane E.; Cowan, Ariel D.; Reazin, Chris; Jumpponen, Ari

    2016-04-01

    Contemporary fires have created high-severity burn areas exceeding historical distributions in forests in the western United States. Until recently, the response of soil ecosystems to high intensity burns has been largely unknown. In complementary studies, we investigated the environmental effect of extreme soil heating, such that occurs with the complete combustion of large down wood during wildfires, on soil fungi and nutrients. We used TRFLP and next generation sequencing (Illumina MiSeq) to investigate the fungal communities. During the burning of large down wood, temperatures lethal to fungi were detected at 0-cm, 5-cm, and 10-cm depths in soils compared to 0-cm depth in soils receiving low intensity broadcast burns. We compared the soil fungal diversity in ten high intensity burned plots paired with adjacent low intensity burned plots before and one week after at 0-10 cm soil depth. Nonmetric Multidimensional Scaling (NMS) ordinations and analyses of taxon frequencies reveal a substantial community turnover and corresponding near complete replacement of the dominant basidiomycetes by ascomycetes in high intensity burns. These coarse-level taxonomic responses were primarily attributable to a few fire-responsive (phoenicoid) fungi, particularly Pyronema sp. and Morchella sp., whose frequencies increased more than 100-fold following high intensity burns. Pinus ponderosa seedlings planted one week post-burn were harvested after four months for EMF root tip analysis. We found: a) greater differences in soil properties and nutrients in high intensity burned soils compared to low intensity burned and unburned soils; b) no differences in EMF richness and diversity; and c) weak differences in community composition based on relative abundance between unburned and either burn treatments. These results confirm the combustion of large downed wood can alter the soil environment directly beneath it. However, an EMF community similar to low burned soils recolonized high

  3. [Metabolic response to high intensity exercise training in sedentary hyperglycemic and hypercholesterolemic women].

    Science.gov (United States)

    Alvarez L, Cristian; Ramírez-Campillo, Rodrigo; Flores O, Marcelo; Henríquez-Olguín, Carlos; Campos J, Christian; Carrasco, Vanesa; Martínez S, Cristian; Celis-Morales, Carlos

    2013-10-01

    High intensity training could be an effective way of improving health on individuals at high metabolic risk. To investigate the effects of a high intensity training intervention on metabolic-related markers in sedentary women at high metabolic risk. Forty six sedentary women with a body mass index (BMI) over 25 kg/m² were assigned to four groups, according to their metabolic profile; hyperglycemia (H, n = 12), hyperglycemia/hypercholesterolemia (HH, n = 13), normoglycemia (N, n = 10) and normoglycemia/hypercholesterolemia (NH, n = 11). For 12 weeks and five days per week, subjects performed seven intervals of high intensity training (20 to 30 seconds) during a training session of 20 minutes. Anthropometric (body weight, body mass index (BMI), waist circumference) and metabolic variables (glucose, total cholesterol, LDL, HDL and TG) were measured at baseline, at 6 and 12 weeks of intervention. BMI and waist circumference decreased significantly after 12 weeks of intervention. Similarly, glucose decreased significantly after 12 weeks of intervention in all groups. The reduction was of higher magnitude in those groups with hyperglycemia (H = -16%, HH = -22%, N = -7,5%, NH = -9,6%). However, lipid profile (TG, total cholesterol, LDL and HDL) improved significantly only in the hypercholesterolemic groups. Physical activity programs incorporating high intensity training can improve glucose and lipid profile in women with metabolic disorders. Moreover, this benefit is greatest in those individuals with highest metabolic burden.

  4. Effects of high-intensity interval training on the VO2 response during severe exercise.

    Science.gov (United States)

    Duffield, Rob; Edge, Johann; Bishop, David

    2006-06-01

    This study examined the effect of high-intensity interval training on the VO2 response during severe, constant-load exercise. Prior to, and following training, 10 females (V O2 peak 37.4+/-6.0 mL kg-1 min-1) performed a graded exercise test to determine VO2 peak and lactate threshold (LT) and a 6 min cycle test (CT) at the pre-training VO2 peak intensity. Training involved high-intensity intervals (2 min work, 1 min rest) performed 3x week for 8 weeks. Breath-by-breath data from 0 to 6 min during the CT were smoothed using 5s averages and fit to a bi-exponential model starting from 20s. Training resulted in significant improvements in VO2 max (2.34+/-0.37-2.78+/-0.30 L min-1), power at VO2 max (170+/-26-204+/-25 W) and power at LT (113+/-17-136+/-20 W) (pVO2 response showed a significant increase in the amplitude of the primary phase (A1) (1396+/-103-1695+/-100 mL min-1; pVO2 (VO2 EE), with no difference (p>0.05) in the time constants of either phase or the amplitude of the slow component (318+/-67-380+/-48 mL; p=0.15). In conjunction, accumulated oxygen deficit (AOD) (43.7+/-9.8-17.2+/-2.8 mL O2 eq kg-1) and anaerobic contribution to the CT (19.4+/-4.4-7.2+/-1.2%) were significantly reduced. In contrast to previous moderate-intensity research, a high-intensity interval training program increased A1 and VO2 EE for the same absolute exercise intensity, decreasing the AOD during a severe-intensity CT.

  5. Deciphering igneous and metamorphic events in high-grade rocks of the Wilmington complex, Delaware: Morphology, cathodoluminescence and backscattered electron zoning, and SHRIMP U-Pb geochronology of zircon and monazite

    Science.gov (United States)

    Aleinikoff, J.N.; Schenck, W.S.; Plank, M.O.; Srogi, L.A.; Fanning, C.M.; Kamo, S.L.; Bosbyshell, H.

    2006-01-01

    High-grade rocks of the Wilmington Complex, northern Delaware and adjacent Maryland and Pennsylvania, contain morphologically complex zircons that formed through both igneous and metamorphic processes during the development of an island-arc complex and suturing of the arc to Laurentia. The arc complex has been divided into several members, the protoliths of which include both intrusive and extrusive rocks. Metasedimentary rocks are interlayered with the complex and are believed to be the infrastructure upon which the arc was built. In the Wilmingto n Complex rocks, both igneous and metamorphic zircons occur as elongate and equant forms. Chemical zoning, shown by cathodoluminescence (CL), includes both concentric, oscillatory patterns, indicative of igneous origin, and patchwork and sector patterns, suggestive of metamorphic growth. Metamorphic monazites are chemically homogeneous, or show oscillatory or spotted chemical zoning in backscattered electron images. U-Pb geochronology by sensitive high resolution ion microprobe (SHRIMP) was used to date complexly zoned zircon and monazite. All but one member of the Wilmington Complex crystallized in the Ordovician between ca. 475 and 485 Ma; these rocks were intruded by a suite of gabbro-to-granite plutonic rocks at 434 ?? Ma. Detrital zircons in metavolcanic and metasedimentary units were derived predominantly from 0.9 to 1.4 Ga (Grenvillian) basement, presumably of Laurentian origin. Amphibolite to granulite facies metamorphism of the Wilmington Complex, recorded by ages of metamorphic zircon (428 ?? 4 and 432 ?? 6 Ma) and monazite (429 ?? 2 and 426 ?? 3 Ma), occurred contemporaneously with emplacement of the younger plutonic rocks. On the basis of varying CL zoning patterns and external morphologies, metamorphic zircons formed by different processes (presumably controlled by rock chemistry) at slightly different times and temperatures during prograde metamorphism. In addition, at least three other thermal episodes are

  6. Rainfall intensity characteristics at coastal and high altitude stations in Kerala

    Indian Academy of Sciences (India)

    V Sasi Kumar; S Sampath; P V S S K Vinayak; R Harikumar

    2007-10-01

    Rainfall intensities measured at a few stations in Kerala during 2001 –2005 using a disdrometer were found to be in reasonable agreement with the total rainfall measured using a manual rain gauge. The temporal distributions of rainfall intensity at different places and during different months show that rainfall is of low intensity (> 10 mm/hr),65%to 90%of the time.This could be an indication of the relative prevalence of stratiform and cumuliform clouds.Rainfall was of intensity > 5 mm/hr for more than 95%of the time in Kochi in July 2002,which was a month seriously deficient in rainfall,indicating that the deficiency was probably due to the relative absence of cumuliform clouds.Cumulative distribution graphs are also plotted and fitted with the Weibull distribution.The fit parameters do not appear to have any consistent pattern. The higher intensities also contributed signi ficantly to total rainfall most of the time,except in Munnar (a hill station). In this analysis also,the rainfall in Kochi in July 2002 was found to have less presence of high intensities. This supports the hypothesis that the rainfall de ficiency was probably caused by the absence of conditions that favoured the formation of cumuliform clouds.

  7. Novel high-energy physics studies using intense lasers and plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Leemans, Wim P. [Univ. of California, Berkeley, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bulanov, Stepan [Univ. of California, Berkeley, CA (United States); Esarey, Eric [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schroeder, Carl [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-06-29

    In the framework of the project “Novel high-energy physics studies using intense lasers and plasmas” we conducted the study of ion acceleration and “flying mirrors” with high intensity lasers in order to develop sources of ion beams and high frequency radiation for different applications. Since some schemes of laser ion acceleration are also considered a good source of “flying mirrors”, we proposed to investigate the mechanisms of “mirror” formation. As a result we were able to study the laser ion acceleration from thin foils and near critical density targets. We identified several fundamental factors limiting the acceleration in the RPA regime and proposed the target design to compensate these limitations. In the case of near critical density targets, we developed a concept for the laser driven ion source for the hadron therapy. Also we studied the mechanism of “flying mirror” generation during the intense laser interaction with thin solid density targets. As for the laser-based positron creation and capture we initially proposed to study different regimes of positron beam generation and positron beam cooling. Since the for some of these schemes a good quality electron beam is required, we studied the generation of ultra-low emittance electron beams. In order to understand the fundamental physics of high energy electron beam interaction with high intensity laser pulses, which may affect the efficient generation of positron beams, we studied the radiation reaction effects.

  8. Beam Dynamics Observations of the 2015 High Intensity Scrubbing Runs at the Cern Sps

    CERN Document Server

    Bartosik, Hannes; Li, Kevin; Mether, Lotta; Romano, Annalisa; Rumolo, Giovanni; Schenk, Michael

    2016-01-01

    Beam quality degradation caused by e-cloud effects has been identified as one of the main performance limitations for high intensity LHC beams with 25 ns bunch spacing in the SPS. In view of the beam parameters targeted with the LHC injectors upgrade (LIU) project, about two weeks of SPS machine time in 2015 were devoted to dedicated scrubbing runs with high intensity LHC 25 ns and dedicated 'doublet' beams in order to study the achievable reduction of e-cloud effects and quantify the consequent beam performance improvements. This paper describes the main observations concerning the coherent instabilities and beam dynamics limitations encountered as well as a detailed characterisation of the performance reach with the highest beam intensity presently available from the pre-injectors.

  9. Oral versus Nasal Breathing during Moderate to High Intensity Submaximal Aerobic Exercise

    Directory of Open Access Journals (Sweden)

    Chase O. LaComb

    2017-01-01

    Full Text Available Introduction: When comparing oral breathing versus nasal breathing, a greater volume of air can be transported through the oral passageway but nasal breathing may also have benefits at submaximal exercise intensities. Purpose: The purpose of this study was to determine breathing efficiency during increasing levels of submaximal aerobic exercise. Methods: Nineteen individuals (males N=9, females N=10 completed a test for maximal oxygen consumption (VO2max and on separate days 4-min treadmill runs at increasing submaximal intensities (50%, 65%, and 80% of VO2max under conditions of oral breathing or nasal breathing. Respiratory (respiration rate [RR], pulmonary ventilation [VE], metabolic (oxygen consumption [VO2], carbon dioxide production [VCO2] and efficiency measures (ventilatory equivalents for oxygen [Veq×O2-1] and carbon dioxide [Veq×CO2-1] were obtained. Data were analyzed utilizing a 2 (sex x 2 (condition x3 (intensity repeated measures ANOVA with significance accepted at p≤0.05. Results: Significant interactions existed between breathing mode and intensity such that oral breathing resulted in greater RR, VE, VO2, and VCO2 at all three submaximal intensities (p<.05.  Veq×O2-1 and Veq×CO2-1 presented findings that nasal breathing was more efficient than oral breathing during the 65% and 80% VO2max intensities (p<0.05. Conclusion: Based on this analysis, oral breathing provides greater respiratory and metabolic volumes during moderate and moderate-to-high submaximal exercise intensities, but may not translate to greater respiratory efficiency. However when all variables are considered together, it is likely that oral breathing represents the more efficient mode, particularly at higher exercise intensities.

  10. Spectral variability of the particulate backscattering ratio

    Science.gov (United States)

    Whitmire, A. L.; Boss, E.; Cowles, T. J.; Pegau, W. S.

    2007-05-01

    The spectral dependency of the particulate backscattering ratio is relevant in the fields of ocean color inversion, light field modeling, and inferring particle properties from optical measurements. Aside from theoretical predictions for spherical, homogeneous particles, we have very limited knowledge of the actual in situ spectral variability of the particulate backscattering ratio. This work presents results from five research cruises that were conducted over a three-year period. Water column profiles of physical and optical properties were conducted across diverse aquatic environments that offered a wide range of particle populations. The main objective of this research was to examine the behavior of the spectral particulate backscattering ratio in situ, both in terms of its absolute magnitude and its variability across visible wavelengths, using over nine thousand 1-meter binned data points for each of five wavelengths of the spectral particulate backscattering ratio. Our analysis reveals no spectral dependence of the particulate backscattering ratio within our measurement certainty, and a geometric mean value of 0.013 for this dataset. This is lower than the commonly used value of 0.0183 from Petzold’s integrated volume scattering data. Within the first optical depth of the water column, the mean particulate backscattering ratio was 0.010.

  11. High-intensity interval training (HIIT for patients with chronic diseases

    Directory of Open Access Journals (Sweden)

    Leanna M. Ross

    2016-06-01

    Full Text Available Exercise training provides physiological benefits for both improving athletic performance and maintaining good health. Different exercise training modalities and strategies exist. Two common exercise strategies are high-intensity interval training (HIIT and moderate-intensity continuous exercise training (MCT. HIIT was first used early in the 20th century and popularized later that century for improving performance of Olympic athletes. The primary premise underlying HIIT is that, compared to energy expenditure-matched MCT, a greater amount of work is performed at a higher intensity during a single exercise session which is achieved by alternating high-intensity exercise intervals with low-intensity exercise or rest intervals. Emerging research suggests that this same training method can provide beneficial effects for patients with a chronic disease and should be included in the comprehensive medical management plan. Accordingly, a major consideration in developing an individual exercise prescription for a patient with a chronic disease is the selection of an appropriate exercise strategy. In order to maximize exercise training benefits, this strategy should be tailored to the individual's need. The focus of this paper is to provide a brief summary of the current literature regarding the use of HIIT to enhance the functional capacity of individuals with cardiovascular, pulmonary, and diabetes diseases.

  12. The effect of high and low exercise intensity periods on a simple memory recognition test

    Institute of Scientific and Technical Information of China (English)

    Ben Rattray; Disa J. Smee

    2016-01-01

    Purpose: The purpose of this study was to investigate the effect of variable intensities on a simple memory recognition task during exercise. Methods: Twenty active participants took part in initial testing, a familiarization trial and then four 60 min cycling interventions in a randomized order. Interventions consisted of no exercise (control), constant exercise at 90%ventilatory threshold (constant) and 2 trials that initially mimicked the constant trial, but then included periods of high (∼90%VO2peak) and low intensities (∼50%VO2peak). Cardiorespiratory measures and capillary blood samples were taken throughout. A short tablet-based cognitive task was completed prior to and during (50 and 55 min into exercise) each intervention. Results: The exercise conditions facilitated response time (p=0.009), although the extent of this effect was not as strong in the variable exercise conditions (p = 0.011–0.089). High intensity exercise periods resulted in some cognitive regression back towards control trial performance. Elevations in cardiorespiratory measures and periods of hypocapnia could not explain changes in cognitive performance. Conclusion: Changes in cognitive performance with variations in exercise intensity are likely to have implications for sport and occupational settings. The timing of cognitive tests to exercise intensity changes as well as use of short cognitive assessments will be important for future work.

  13. High-intensity interval training (HIIT) for patients with chronic diseases

    Institute of Scientific and Technical Information of China (English)

    Leanna M. Ross; Ryan R. Porter; J. Larry Durstine

    2016-01-01

    Exercise training provides physiological benefits for both improving athletic performance and maintaining good health. Different exercise training modalities and strategies exist. Two common exercise strategies are high-intensity interval training (HIIT) and moderate-intensity continuous exercise training (MCT). HIIT was first used early in the 20th century and popularized later that century for improving performance of Olympic athletes. The primary premise underlying HIIT is that, compared to energy expenditure-matched MCT, a greater amount of work is performed at a higher intensity during a single exercise session which is achieved by alternating high-intensity exercise intervals with low-intensity exercise or rest intervals. Emerging research suggests that this same training method can provide beneficial effects for patients with a chronic disease and should be included in the comprehensive medical management plan. Accordingly, a major consideration in developing an individual exercise prescription for a patient with a chronic disease is the selection of an appropriate exercise strategy. In order to maximize exercise training benefits, this strategy should be tailored to the individual’s need. The focus of this paper is to provide a brief summary of the current literature regarding the use of HIIT to enhance the functional capacity of individuals with cardiovascular, pulmonary, and diabetes diseases.

  14. High Intensity Interval Training in Handcycling : The Effects of a 7 Week Training Intervention in Able-bodied Men

    NARCIS (Netherlands)

    Schoenmakers, Patrick; Reed, Kate; Van Der Woude, Luc; Hettinga, Florentina J.

    2016-01-01

    INTRODUCTION: In lower body endurance training, quantities of both moderate intensity continuous training (MICT) and high intensity interval training (HIIT) can lead to an improved physiological capacity and performance. Limited research is available regarding the endurance and muscular capacity of

  15. Effects of high-intensity interval versus mild-intensity endurance training on metabolic phenotype and corticosterone response in rats fed a high-fat or control diet.

    Science.gov (United States)

    Shen, Youqing; Huang, Guoyuan; McCormick, Bryan P; Song, Tao; Xu, Xiangfeng

    2017-01-01

    The aim of the present study was to compare the effects of high-intensity interval training (HI) to mild-intensity endurance training (ME), combined with a high-fat diet (HFD) or control diet (CD) on metabolic phenotype and corticosterone levels in rats. Fifty-three rats were randomized to 6 groups according to diet and training regimen as follows: CD and sedentary (CS, n = 11), CD and ME (CME, n = 8), CD and HI (CHI, n = 8), HFD and sedentary (HS, n = 10), HFD and ME (HME, n = 8), and HFD and HI (HHI, n = 8). All exercise groups were trained for 10 weeks and had matched running distances. Dietary intake, body composition, blood metabolites, and corticosterone levels were measured. Histological lipid droplets were observed in the livers. The HFD led to hyperglycemia, hyperlipidemia and higher body fat (all, P 0.06), as well as higher corticosterone levels (P training improved fat weight, glucose, and lipid profiles, and reduced corticosterone levels (P training compared to ME training. Reductions in HFD-induced body weight gain, blood glucose and lipid profiles, and corticosterone levels, as well as improvements in QUICKI were better with HHI compared to HME. Correlation analyses revealed that corticosterone levels were significantly associated with phenotype variables (P training, HI training contributes to greater improvements in metabolic and corticosterone responses, leading to a greater reduction in susceptibility to HFD-induced disorders.

  16. Artificial electron heating of winter mesospheric radar clouds (PMWE) and the interpretation of the radar backscatter variation during the heater cycling.

    Science.gov (United States)

    Kassa Bekele, Meseret; Havnes, Ove; La Hoz, Cesar; Baroni, Giovanni; Rietveld, Mike; Biebricher, Alexander

    The effect of artificial electron heating (in our case with the EISCAT Heating Facility) on the Polar Mesospheric Winter Echoes (PMWE) the weak radar clouds which occur in the winter mesosphere between heights 55 to 80 km, is normally different from its effect on the much stronger Polar Mesospheric Summer Echoes (PMSE) which occur between 80 and 90 km height. They both show a weakening of the backscatter when the heater is switched on, sometimes close to extinguishing of the radar backscatter, signaling that the increased electron pressure has smoothed the electron density gradients which are responsible for the coherent backscatter. However, while the PMSE backscatter very often show a considerable recovery during the 20 sec the heater (normally) is on and dust particles are charged more negatively by the heated electrons, this recovery is at best very weak for PMWE. The PMWE also have weak overshoots, where the backscatter flares up only by a factor 1.1 to 1.2 when the heater is switched off, compared to the undisturbed PMWE backscatter before the heater was switched on. For PMSE the overshoot factor can be as high as 7. This demonstrate that if dust particles control the PMWE their sizes must be much smaller than the PMSE particles. Modeling has shown that the likely PMWE dust sizes are in the range 3-4 nanometer making it probable that PMWE is associated with the small meteoric smoke particles. When the heater is switched off the charge of the dust particles and the intensity of the backscatter relax back to its undisturbed values. If the decharging mechanism was the same for the larger PMSE and the small PMWE dust particles one would expect a very much longer relaxation time for the PMWE than for the PMSE. The fact that the PMWE relaxation time is comparable to the PMSE show that the small meteoric dust particles must be de-charged by a more effective mechanism than ion attachment. We find that the photodetachment effect where photons of energy less than the

  17. Moderate-to-high intensity aerobic exercise in patients with mild to moderate Alzheimer's disease

    DEFF Research Database (Denmark)

    Frederiksen, Kristian S; Sobol, Nanna; Beyer, Nina

    2014-01-01

    OBJECTIVES: Physical exercise may modulate neuropathology and symptoms of Alzheimer's disease (AD). This pilot study assessed the feasibility of conducting a study of moderate-to-high intensity aerobic exercise in home-dwelling patients with mild AD. METHODS: An uncontrolled preintervention...

  18. High Intensity Pressure Noise Transmission in Human Ear: A Three Dimensional Simulation Study

    Science.gov (United States)

    Hawa, Takumi; Gan, Rong; Leckness, Kegan

    2015-03-01

    High intensity pressure noise generated by explosions and jet engines causes auditory damage and hearing loss of the military service personals, which are the most common disabilities in the veterans. Authors have investigated the high intensity pressure noise transmission from the ear canal to middle ear cavity. A fluid-structure interaction with a viscoelastic model for the tympanic membrane (TM) as well as the ossicular chain has been considered in the study. For the high intensity pressure simulation the geometry of the ear was based on a 3D finite element (FE) model of the human ear reported by Gan et al. (Ann Biomed Eng 2004). The model consists of the ear canal, TM, ossicular chain, and the middle ear cavity. The numerical approach includes two steps: 1) FE based finite-volume method simulation to compute pressure distributions in the ear canal and the middle ear cavity using CFX; and 2) FE modeling of TM and middle ear ossicles in response to high intensity sound using multi-physics analysis in ANSYS. The simulations provide the displacement of the TM/ossicular chain and the pressure fields in the ear canal and the middle ear cavity. These results are compared with human temporal bone experimental data obtained in our group. This work was supported by DOD W81XWH-14-1-0228.

  19. Edward Teller medal lecture: high intensity lasers and the road to ignition

    Energy Technology Data Exchange (ETDEWEB)

    Key, M.H.

    1997-06-02

    There has been much progress in the development of high intensity lasers and in the science of laser driven inertially confined fusion such that ignition is now a near term prospect. This lecture reviews the field with particular emphasis on areas of my own involvement.

  20. Dose estimation and shielding calculation for X-ray hazard at high intensity laser facilities

    Science.gov (United States)

    Qiu, Rui; Zhang, Hui; Yang, Bo; James, C. Liu; Sayed, H. Rokni; Michael, B. Woods; Li, Jun-Li

    2014-12-01

    An ionizing radiation hazard produced from the interaction between high intensity lasers and solid targets has been observed. Laser-plasma interactions create “hot” electrons, which generate bremsstrahlung X-rays when they interact with ions in the target. However, up to now only limited studies have been conducted on this laser-induced radiological protection issue. In this paper, the physical process and characteristics of the interaction between high intensity lasers and solid targets are analyzed. The parameters of the radiation sources are discussed, including the energy conversion efficiency from laser to hot electrons, hot electron energy spectrum and electron temperature, and the bremsstrahlung X-ray energy spectrum produced by hot electrons. Based on this information, the X-ray dose generated with high-Z targets for laser intensities between 1014 and 1020 W/cm2 is estimated. The shielding effects of common shielding items such as the glass view port, aluminum chamber wall and concrete wall are also studied using the FLUKA Monte Carlo code. This study provides a reference for the dose estimation and the shielding design of high intensity laser facilities.

  1. Burden of highly resistant microorganisms in a Dutch intensive care unit

    NARCIS (Netherlands)

    Aardema, H.; Arends, J. P.; de Smet, A. M. G. A.; Zijlstra, J. G.

    2015-01-01

    Background: The occurrence of highly resistant microorganisms (HRMOs) is a major threat to critical care patients, leading to worse outcomes, need for isolation measures, and demand for second-line or rescue antibiotics. The aim of this study was to quantify the burden of HRMOs in an intensive care

  2. Windowless microfluidic platform based on capillary burst valves for high intensity x-ray measurements

    DEFF Research Database (Denmark)

    Vig, Asger Laurberg; Haldrup, Kristoffer; Enevoldsen, Nikolaj Brandt;

    2009-01-01

    We propose and describe a microfluidic system for high intensity x-ray measurements. The required open access to a microfluidic channel is provided by an out-of-plane capillary burst valve (CBV). The functionality of the out-of-plane CBV is characterized with respect to the diameter of the window...

  3. Selected List of Low Energy Beam Transport Facilities for Light-Ion, High-Intensity Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Prost, L. R. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

    2016-02-17

    This paper presents a list of Low Energy Beam Transport (LEBT) facilities for light-ion, high-intensity accelerators. It was put together to facilitate comparisons with the PXIE LEBT design choices. A short discussion regarding the importance of the beam perveance in the choice of the transport scheme follows.

  4. A numerical and experimental investigation of the performance of sound intensity probes at high frequencies

    DEFF Research Database (Denmark)

    Jacobsen, Finn; Cutanda, Vicente; Juhl, Peter Møller

    1998-01-01

    The high-frequency performance of a p-p intensity probe with a solid spacer between the two microphones is examined. It is shown theoretically and verified experimentally that with a spacer length that equals the diameter of the microphones, the finite difference error is almost perfectly cancelled...

  5. Triggered Drug Release from Superhydrophobic Meshes using High-Intensity Focused Ultrasound

    OpenAIRE

    Yohe, Stefan T.; Kopechek, Jonathan A.; Porter, Tyrone M; Colson, Yolonda L.; Grinstaff, Mark W.

    2013-01-01

    Application of high-intensity focused ultrasound to drug-loaded superhydrophobic meshes affords triggered drug release by displacing an entrapped air layer. The air layer within the superhydrophobic meshes is characterized using direct visualization and B-mode imaging. Drug-loaded superhydrophobic meshes are cytotoxic in an in vitro assay after ultrasound treatment.

  6. Towards MR-guided high intensity focused ultrasound ablation of liver tumors

    NARCIS (Netherlands)

    Wijlemans, J.W.

    2015-01-01

    Magnetic Resonance-guided High Intensity Focused Ultrasound (MR-HIFU) is a promising technique which can be used for completely non-invasive tissue ablation. The converging ultrasound beam penetrates the skin and subcutaneous tissues with damage, while heating the tissue only in the focal point. The

  7. MRI-guided High-Intensity Focused Ultrasound of Breast Cancer

    NARCIS (Netherlands)

    Merckel, L.G.

    2014-01-01

    Magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for completely noninvasive tumor ablation. This thesis focuses on its application for the treatment of patients with breast cancer. The first part of the thesis describes the role of breast MRI for

  8. Work in progress at the North Area High Intensity Facility (NAHIF)

    CERN Document Server

    1979-01-01

    The photo shows the exit of the two MBN-type magnets in tunnel TDC85 (upstream of TCC8), used to 'switch' the primary proton beam either towards target T8 (to the left) or onto target T10 (straight) to produce the H10 or the F12 (high-intensity electron/gamma) beam, respectively.

  9. 21 CFR 1040.30 - High-intensity mercury vapor discharge lamps.

    Science.gov (United States)

    2010-04-01

    ... mercury and that is contained within an outer envelope. (2) Advertisement means any catalog, specification... ballast is an inductive reactor designed to have the operating characteristics as listed in Section 7 in... advertisement. Advertising for any high-intensity mercury vapor discharge lamp that does not comply...

  10. Bone metastasis treatment using magnetic resonance-guided high intensity focused ultrasound

    NARCIS (Netherlands)

    Yeo, Sin Yuin; Elevelt, Aaldert; Donato, Katia; van Rietbergen, Bert; ter Hoeve, Natalie D.; van Diest, Paul J.; Grüll, Holger

    2015-01-01

    Objectives: Bone pain resulting from cancer metastases reduces a patient's quality of life. Magnetic Resonance-guided High Intensity Focused Ultrasound (MR-HIFU) is a promising alternative palliative thermal treatment technique for bone metastases that has been tested in a few clinical studies. Here

  11. Creatine supplementation spares muscle glycogen during high intensity intermittent exercise in rats

    Directory of Open Access Journals (Sweden)

    Costa André

    2010-01-01

    Full Text Available Abstract Background The effects of creatine (CR supplementation on glycogen content are still debatable. Thus, due to the current lack of clarity, we investigated the effects of CR supplementation on muscle glycogen content after high intensity intermittent exercise in rats. Methods First, the animals were submitted to a high intensity intermittent maximal swimming exercise protocol to ensure that CR-supplementation was able to delay fatigue (experiment 1. Then, the CR-mediated glycogen sparing effect was examined using a high intensity intermittent sub-maximal exercise test (fixed number of bouts; six bouts of 30-second duration interspersed by two-minute rest interval (experiment 2. For both experiments, male Wistar rats were given either CR supplementation or placebo (Pl for 5 days. Results As expected, CR-supplemented animals were able to exercise for a significant higher number of bouts than Pl. Experiment 2 revealed a higher gastrocnemius glycogen content for the CR vs. the Pl group (33.59%. Additionally, CR animals presented lower blood lactate concentrations throughout the intermittent exercise bouts compared to Pl. No difference was found between groups in soleus glycogen content. Conclusion The major finding of this study is that CR supplementation was able to spare muscle glycogen during a high intensity intermittent exercise in rats.

  12. Productions of hollow atoms from solids irradiated by high intensity laser

    Energy Technology Data Exchange (ETDEWEB)

    Moribayashi, K.; Sasaki, A.; Zhidkov, A. [Advanced Photon Research Center, Kansai Research Establishment, Japan Atomic Energy Research Inst. (Japan)

    2001-07-01

    The production of hollow atoms through the collisions of fast electrons with a solid is studied. These electrons are produced by high-intensity short-pulse laser irradiation on a solid. The inner-shell ionization and excitation processes by the fast electron impact are investigated. It is found that ionization processes give more significant contribution to the production of hollow atoms. (orig.)

  13. Status of High Intensity Polarized Electron Gun at Mit-Bates

    Science.gov (United States)

    Tsentalovich, E.; Bessuille, J.; Tiunov, M.

    2011-01-01

    MIT-Bates, in collaboration with BNL, has developed a high intensity polarized electron gun for the eRHIC project. The gun implements large area cathode, ring-shaped beam and active cathode cooling. The paper describes the current status of the project.

  14. The Edward Teller Medal Lecture: High Intensity Lasers and the Road to Ignition (lirpp Vol. 13)

    Science.gov (United States)

    Key, M. H.

    2016-10-01

    There has been much progress in the development of high intensity lasers and in the science of laser driven inertially confined fusion such that ignition is now a near term prospect. This lecture reviews the field with particular emphasis on areas of my own involvement.

  15. MRI-guided High-Intensity Focused Ultrasound of Breast Cancer

    NARCIS (Netherlands)

    Merckel, L.G.

    2014-01-01

    Magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for completely noninvasive tumor ablation. This thesis focuses on its application for the treatment of patients with breast cancer. The first part of the thesis describes the role of breast MRI for

  16. High-level fusion of depth and intensity for pedestrian classification

    NARCIS (Netherlands)

    Rohrbach, M.; Enzweiler, M.; Gavrila, D.M.

    2009-01-01

    This paper presents a novel approach to pedestrian classification which involves a high-level fusion of depth and intensity cues. Instead of utilizing depth information only in a pre-processing step, we propose to extract discriminative spatial features (gradient orientation histograms and local

  17. Postexercise cold-water immersion improves intermittent high-intensity exercise performance in normothermia.

    Science.gov (United States)

    McCarthy, Avina; Mulligan, James; Egaña, Mikel

    2016-11-01

    A brief cold water immersion between 2 continuous high-intensity exercise bouts improves the performance of the latter compared with passive recovery in the heat. We investigated if this effect is apparent in normothermic conditions (∼19 °C), employing an intermittent high-intensity exercise designed to reflect the work performed at the high-intensity domain in team sports. Fifteen young active men completed 2 exhaustive cycling protocols (Ex1 and Ex2: 12 min at 85% ventilatory threshold (VT) and then an intermittent exercise alternating 30-s at 40% peak power (Ppeak) and 30 s at 90% Ppeak to exhaustion) separated by 15 min of (i) passive rest, (ii) 5-min cold-water immersion at 8 °C, and (iii) 10-min cold-water immersion at 8 °C. Core temperature, heart rate, rates of perceived exertion, and oxygen uptake kinetics were not different during Ex1 among conditions. Time to failure during the intermittent exercise was significantly (P intermittent high-intensity exercise compared with passive rest in normothermia due, at least in part, to reductions in core temperature, circulatory strain, and effort perception.

  18. Effects of 12 weeks high-intensity & reduced-volume training in elite athletes

    DEFF Research Database (Denmark)

    Kilen, Anders; Larsson, Tanja Hultengren; Jørgensen, Majke;

    2014-01-01

    It was investigated if high-intensity interval training (HIT) at the expense of total training volume improves performance, maximal oxygen uptake and swimming economy. 41 elite swimmers were randomly allocated to a control (CON) or HIT group. For 12 weeks both groups trained ∼12 h per week. HIT c...

  19. Responses of Plasma Atrial Natriuretic Peptide to High Intensity Submaximal Exercise in the Heat,

    Science.gov (United States)

    1987-06-01

    Natriuretic Peptide to LnHigh Intensity Submaximal Exercise in the Heat 0 " William J. Kraemer. Lawrence E. Armstrong, Roger W. Hubbard. :I[_] Louis J...atriopeptins in rat adrenal cells. Cir Res 57: 113-118. f V-0C -- V- - IF -I 7 - % 7 -. 17 Chartier L. Schiffrin EL. Thibault G (1984). Effects of atrial

  20. Ionization and acceleration of heavy ions in high-Z solid target irradiated by high intensity laser

    OpenAIRE

    Kawahito, D.; Kishimoto, Y

    2016-01-01

    In the interaction between high intensity laser and solid film, an ionization dynamics inside the solid is dominated by fast time scale convective propagation of the internal sheath field and the slow one by impact ionization due to heated high energy electrons coupled with nonlocal heat transport. Furthermore, ionization and acceleration due to the localized external sheath field which co- propagates with Al ions constituting the high energy front in the vacuum region. Through this process, ...

  1. Plasma Irisin Modestly Increases during Moderate and High-Intensity Afternoon Exercise in Obese Females

    Science.gov (United States)

    Winn, Nathan C.; Grunewald, Zachary I.; Liu, Ying; Heden, Timothy D.; Nyhoff, Lauren M.; Kanaley, Jill A.

    2017-01-01

    Background and Purpose Irisin is an exercise-responsive myokine that has been proposed to exert anti-obesity benefits; yet its response during exercise in obese women is not described. This study characterized plasma irisin levels during a single bout of afternoon isocaloric-exercise of different intensities (moderate- vs high-intensity) in obese females. Methods Eleven obese females participated in 3 randomized study days beginning at 1600h: 1) no exercise (NoEx), 2) moderate exercise (ModEx; 55%VO2max) and 3) high intensity interval exercise (IntEx; 4 min (80%VO2max)/3 min (50% VO2max). Frequent blood samples were analyzed for glucose and lactate (whole-blood), and insulin, c-peptide, glucagon, and irisin (plasma) throughout 190 min of testing. Results Plasma irisin increased above baseline during ModEx and IntEx (P0.05). Peak irisin levels during ModEx and IntEx exercise were 11.9± 3.4% and 12.3 ± 4.1% relative to baseline (Pexercise intensities (P>0.05). Irisin levels remained elevated above resting for 125 minutes post-exercise during ModEx, whereas levels returned to baseline within 15 minutes post-exercise during IntEx. Similarly, no associations were found between plasma irisin levels and circulating lactate, glucose, insulin, c-peptide, or glucagon among study days (P>0.05). However, there was an inverse association between basal irisin and lean mass (r = -0.70, P = 0.01). Conclusion A single bout of moderate and high intensity afternoon exercise induces modest increases in circulating irisin concentrations during exercise; however the regulation post-exercise appears to be dimorphic between exercise intensity in obese females. Future studies are needed to compare morning and afternoon exercise on irisin secretion. PMID:28125733

  2. New technologies in lighting systems for high-speed film and photography regarding high-intensity and heat problems

    Science.gov (United States)

    Severon, Burkhard

    1991-04-01

    Increasing frame rates and the heat sensibility of test objects forced the development of new lighting systems. For example at the automotive industry, where continuous light sources are indispensable for the high speed photography of car crash tests and automobile components tests, the further development of high efficient safety systems, so as Air-Bag systems, needs very datailed analysis of the accelerated motions. Frame rates from 2.000 up to 10.000 frames per second are requested and beside adequate camera systems and film material, this also means high intensive lighting systems. The need for high intensity could be easy achieved by the use of additional light fixtures but the request for more intensity comes along with the problem of heat. The test objects and the auxiliary materials become more and more temperature- sensitive. Very offen they have to be used under strict climate conditions. Mainly there where the test objects are already placed inside the illuminated area, the heat radiation of the light sources to the test objects have to be reduced. So high intensive, flicker free and less heat are today's requirements of light performance. This paper will present solutions to meet those demands.

  3. High harmonic generation from bulk diamond driven by intense femtosecond laser pulse

    CERN Document Server

    Apostolova, Tzveta

    2016-01-01

    We investigate the high-harmonic generation (HHG) from bulk diamond induced by intense 15 fs laser pulse and photon energy 1.55 eV. For laser intensity in the range $I \\in [1,50]$ TW/cm$^2$, we find that HHG spectra from diamond exhibits two plateaus with high harmonics extending beyond the 50th order. Consistently with experimental observations, we find that the cutoff energy of the two plateaus scales linearly with the field strength. The first plateau is due to recombination of electron-hole pairs near the Brillouin zone center. The appearance of weak second plateau region for high field strength with $F \\sim$ 1 V/$\\AA$ results in emission of highly energetic XUV photons.

  4. Recovery of a soil under different vegetation one year after a high intensity wildfire

    Directory of Open Access Journals (Sweden)

    A. Martín

    2013-05-01

    Full Text Available Studies on soil recovery in fragile ecosystems following high intensity wildfires are scarce. The aim of the present investigation is to evaluate the impact of a high intensity wildfire in an ecosystem under different vegetation (shrubland and pinewood located at Vilardevós (Galicia, NW Spain and highly susceptible to suffer soil erosion due to the steep relief and high erositivity of the rainfall. Soil samples were collected from the A horizon (0-5 cm 1 year after the fire and soil quality was evaluated by analysis of several physical, chemical and biochemical properties measured in the fraction chemical properties > physical properties. The data also showed that the fire impact was different depending on the soil vegetation considered (shrubland and pinewood. Moreover, the data confirmed the slow soil recovery in this fragile ecosystem and, therefore, the need of adopting post-fire stabilisation and rehabilitation treatments in order to minimize the post-fire erosion and soil degradation.

  5. High-Resolution Energy and Intensity Measurements with CVD Diamond at REX-ISOLDE

    CERN Document Server

    Griesmayer, E; Dobos, D; Wenander, F; Bergoz, J; Bayle, H; Frais-Kölbl, H; Leinweber, J; Aumeyr, T; CERN. Geneva. BE Department

    2009-01-01

    A novel beam instrumentation device for the HIE-REX (High In-tensity and Energy REX) upgrade has been developed and tested at the On-Line Isotope Mass Separator ISOLDE, located at the European Laboratory for Particle Physics (CERN). This device is based on CVD diamond detector technology and is used for measuring the beam intensity, particle counting and measuring the energy spectrum of the beam. An energy resolution of 0.6% was measured at a carbon ion energy of 22.8 MeV. This corresponds to an energy spread of ± 140 keV.

  6. Start-to-end simulations for the proposed Fermilab high intensity proton source

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Jean-Paul; Johnson, D.E.; Webber, R.C.; /Fermilab

    2007-06-01

    A High Intensity Proton Source consisting in an 8 GeV superconducting H-minus linac and transfer line to the Main Injector has been proposed. The primary mission is to increase the intensity of the Fermilab Main Injector for the production of neutrino superbeams. Start-to-end simulations from the RFQ to the stripping foil using the simulation code TRACK (ANL) is presented in this paper. In particular, we will study the impact of jitter errors on the H-minus phase space at the stripping foil.

  7. High-Energy Ions Emitted from Ar Clusters Irradiated by Intense Femtosecond Laser Pulses

    Institute of Scientific and Technical Information of China (English)

    LI Zhong; LEI An-Le; NI Guo-Quan; XU Zhi-Zhan

    2000-01-01

    We have experimentally studied the energy spectra of Ar ions emitted from Ar clusters irradiated by intense femtosecond laser pulses. The Ar clusters were produced in the adiabatic expansion of Ar gas into vacuum at high backing pressures. The laser peak intensity was about 2×106 W/cm2 with a pulse duration of 45 fs. The maximum and the average energies of Ar ions are 0.2 MeV and 15kev at a backing pressure of 2. S MPa, respectively. They are almost independent of the backing pressures in the range of 0.6 to 4.5 MPa.

  8. Salutary effects of high-intensity interval training in persons with elevated cardiovascular risk.

    Science.gov (United States)

    Fleg, Jerome L

    2016-01-01

    Although moderate-intensity continuous training (MICT) has been the traditional model for aerobic exercise training for over four decades, a growing body of literature has demonstrated equal if not greater improvement in aerobic capacity and similar beneficial effects on body composition, glucose metabolism, blood pressure, and quality of life from high-intensity interval training (HIIT). An advantage of HIIT over MICT is the shorter time required to perform the same amount of energy expenditure. The current brief review summarizes the effects of HIIT on peak aerobic capacity and cardiovascular risk factors in healthy adults and those with various cardiovascular diseases, including coronary artery disease, chronic heart failure, and post heart transplantation.

  9. Acute Effect of High-Intensity Eccentric Exercise on Vascular Endothelial Function in Young Men.

    Science.gov (United States)

    Choi, Youngju; Akazawa, Nobuhiko; Zempo-Miyaki, Asako; Ra, Song-Gyu; Shiraki, Hitoshi; Ajisaka, Ryuichi; Maeda, Seiji

    2016-08-01

    Choi, Y, Akazawa, N, Zempo-Miyaki, A, Ra, S-G, Shiraki, H, Ajisaka, R, and Maeda, S. Acute effect of high-intensity eccentric exercise on vascular endothelial function in young men. J Strength Cond Res 30(8): 2279-2285, 2016-Increased central arterial stiffness is as an independent risk factor for cardiovascular disease. Evidence regarding the effects of high-intensity resistance exercise on vascular endothelial function and central arterial stiffness is conflicting. The purpose of this study was to examine the effects of acute high-intensity eccentric exercise on vascular endothelial function and central arterial stiffness. We evaluated the acute changes in endothelium-dependent flow-mediated dilation (FMD), low-flow-mediated constriction (L-FMC), and arterial stiffness after high-intensity eccentric exercise. Seven healthy, sedentary men (age, 24 ± 1 year) performed maximal eccentric elbow flexor exercise using their nondominant arm. Before and 45 minutes after eccentric exercise, carotid arterial compliance and brachial artery FMD and L-FMC in the nonexercised arm were measured. Carotid arterial compliance was significantly decreased, and β-stiffness index significantly increased after eccentric exercise. Brachial FMD was significantly reduced after eccentric exercise, whereas there was no significant difference in brachial L-FMC before and after eccentric exercise. A positive correlation was detected between change in arterial compliance and change in FMD (r = 0.779; p ≤ 0.05), and a negative correlation was detected between change in β-stiffness index and change in FMD (r = -0.891; p eccentric exercise. In this study, acute high-intensity eccentric exercise increased central arterial stiffness; this increase was accompanied by a decrease in endothelial function caused by reduced endothelium-dependent vasodilation but not by a change in endothelium-dependent vasoconstriction.

  10. Psychophysiological effects of music on acute recovery from high-intensity interval training.

    Science.gov (United States)

    Jones, Leighton; Tiller, Nicholas B; Karageorghis, Costas I

    2017-03-01

    Numerous studies have examined the multifarious effects of music applied during exercise but few have assessed the efficacy of music as an aid to recovery. Music might facilitate physiological recovery via the entrainment of respiratory rhythms with music tempo. High-intensity exercise training is not typically associated with positive affective responses, and thus ways of assuaging negative affect warrant further exploration. This study assessed the psychophysiological effects of music on acute recovery and prevalence of entrainment in between bouts of high-intensity exercise. Thirteen male runners (Mage=20.2±1.9years; BMI=21.7±1.7; V̇O2 max=61.6±6.1mL·kg·min(-1)) completed three exercise sessions comprising 5×5-min bouts of high-intensity intervals interspersed with 3-min periods of passive recovery. During recovery, participants were administered positively-valenced music of a slow-tempo (55-65bpm), fast-tempo (125-135bpm), or a no-music control. A range of measures including affective responses, RPE, cardiorespiratory indices (gas exchange and pulmonary ventilation), and music tempo-respiratory entrainment were recorded during exercise and recovery. Fast-tempo, positively-valenced music resulted in higher Feeling Scale scores throughout recovery periods (p<0.01, ηp(2)=0.38). There were significant differences in HR during initial recovery periods (p<0.05, ηp(2)=0.16), but no other music-moderated differences in cardiorespiratory responses. In conclusion, fast-tempo, positively-valenced music applied during recovery periods engenders a more pleasant experience. However, there is limited evidence that music expedites cardiorespiratory recovery in between bouts of high-intensity exercise. These findings have implications for athletic training strategies and individuals seeking to make high-intensity exercise sessions more pleasant.

  11. On the backscatter of solar He II, 304 A radiation from interplanetary He/+/.

    Science.gov (United States)

    Paresce, F.; Bowyer, S.

    1973-01-01

    Backscatter of solar He II, 304 A radiation by interplanetary positive helium ions is shown to be insufficient to account for recent observations of this airglow radiation in the night sky at rocket altitudes. In fact, for most viewing directions, the expected intensities probably fall well below the sensitivity threshold of existing extreme ultraviolet instrumentation.

  12. Intensive lifestyle intervention including high-intensity interval training program improves insulin resistance and fasting plasma glucose in obese patients

    Directory of Open Access Journals (Sweden)

    Guillaume Marquis-Gravel

    2015-01-01

    Conclusion: Following a 9-month intensive lifestyle intervention combining HIIT and MedD counseling, obese subjects experienced significant improvements of FPG and insulin resistance. This is the first study to expose the effects of a long-term program combining HIIT and MedD on glycemic control parameters among obese subjects.

  13. Using high-fidelity simulation as a learning strategy in an undergraduate intensive care course.

    Science.gov (United States)

    Badir, Aysel; Zeybekoğlu, Zuhal; Karacay, Pelin; Göktepe, Nilgün; Topcu, Serpil; Yalcin, Begüm; Kebapci, Ayda; Oban, Gül

    2015-01-01

    Using high-fidelity simulations to facilitate student learning is an uncommon practice in Turkish nursing programs. The aim of the present study was to understand students' perceptions of the use of simulation in nursing courses. Subjects included 36 senior nursing students taking an intensive care course. This study revealed that high-fidelity simulation is an ideal method of promoting learning by helping students transfer theory into practice, build confidence and teamwork, and raise professional awareness.

  14. Personalized Metabolomics for Predicting Glucose Tolerance Changes in Sedentary Women After High-Intensity Interval Training

    OpenAIRE

    Kuehnbaum, Naomi L.; Gillen, Jenna B.; Gibala, Martin J.; Britz-McKibbin, Philip

    2014-01-01

    High-intensity interval training (HIIT) offers a practical approach for enhancing cardiorespiratory fitness, however its role in improving glucose regulation among sedentary yet normoglycemic women remains unclear. Herein, multi-segment injection capillary electrophoresis-mass spectrometry is used as a high-throughput platform in metabolomics to assess dynamic responses of overweight/obese women (BMI > 25, n = 11) to standardized oral glucose tolerance tests (OGTTs) performed before and after...

  15. Report from the NSLS workshop: Sources and applications of high intensity uv-vuv light

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.D.; Hastings, J.B. [eds.

    1990-12-31

    A workshop was held to evaluate sources and applications of high intensity, ultra violet (UV) radiation for biological, chemical, and materials sciences. The proposed sources are a UV free electron laser (FEL) driven by a high brightness linac and undulators in long, straight sections of a specially designed low energy (400 MeV) storage ring. These two distinct types of sources will provide a broad range of scientific opportunities that were discussed in detail during the workshop.

  16. Report from the NSLS workshop: Sources and applications of high intensity uv-vuv light

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.D.; Hastings, J.B. (eds.)

    1990-01-01

    A workshop was held to evaluate sources and applications of high intensity, ultra violet (UV) radiation for biological, chemical, and materials sciences. The proposed sources are a UV free electron laser (FEL) driven by a high brightness linac and undulators in long, straight sections of a specially designed low energy (400 MeV) storage ring. These two distinct types of sources will provide a broad range of scientific opportunities that were discussed in detail during the workshop.

  17. Repeated high-intensity running and sprinting in elite women’s soccer competition

    OpenAIRE

    Gabbett, Tim J; Wiig, Håvard; Spencer, Matt

    2013-01-01

    Background: To the authors’ knowledge, no study has investigated the concurrent repeated, high-intensity (RHIA) and repeated-sprint activity (RSA) of intermittent team-sport competition. Purpose: In this study, they report on the RSA of elite women’s football competition. In addition, they describe the nature of RHIA (eg, striding and sprinting activities) that involve a high energy cost and are associated with short (ie, ≤20 s) recovery periods. Methods: Thirteen elite women soccer players u...

  18. Tune measurements with high intensity ion beams at GSI SIS-18

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Rahul [GSI, Darmstadt (Germany); TEMF, TU Darmstadt (Germany); Forck, Peter; Kowina, Piotr; Kaufmann, Wolfgang [GSI, Darmstadt (Germany); Weiland, Thomas [TEMF, TU Darmstadt (Germany)

    2012-07-01

    A precise tune measurement during a full accelerating cycle is required to achieve stable high current operation. A new system has been commissioned at GSI for position, orbit and tune measurements. It consists of three distinct parts; an exciter which provides power to excite coherent betatron oscillations in the bunched beam; Fast ADCs to digitize the BPM signals at 125 MSa/s; the post processing electronics uses digitized BPM signals to acquire one position value per bunch. Subsequently the baseband tune is determined by Fourier transformation of the position data. Experiments were conducted to understand the effects of high beam intensity on tune at injection plateau (11.4 MeV/u) and during acceleration ramp (11.4-600 MeV/u). These experiments were performed with U{sup 73+} and Ar{sup 18+} ion beam at highest achievable intensities of 2.10{sup 9} and 2.5.10{sup 10} respectively. Tune shift with increased intensity was observed. The working principle of the tune measurement system and observed high intensity effects on tune will be reported in this contribution.

  19. The effects of light emitting diode therapy following high intensity exercise.

    Science.gov (United States)

    Denis, Romain; O'Brien, Christopher; Delahunt, Eamonn

    2013-05-01

    To determine the effects of light emitting diode therapy (LEDT) irradiation on blood lactate concentration ([La]) clearance, peak power output and fatigue index (FI) following high intensity fatiguing exercise. Single-blinded randomised cross-over placebo controlled trial. University College Dublin, Institute for Sport and Health, Human performance laboratory. Eighteen healthy male athletes were recruited from field-based sports (including soccer, hockey and rugby union) and participated in the present study. Dependent variables were the peak power output elicited during the Wingate Anaerobic Test (WAnT), FI and [La] before and after each exercise. WAnT performance was measured prior to high intensity fatiguing exercise (Yo-Yo IR2), prior to LEDT or placebo, and following LEDT or placebo. [La] was measured at baseline, immediately after the Yo-Yo IR2, and in the 3rd, 9th, and 15th min following LEDT or placebo condition. No significant group by treatment interactions were observed for any outcome measures (P > 0.05). We conclude that LEDT irradiation applied following high intensity exercise was not effective and has no immediate effect on [La] clearance, peak power and FI, and thus has no significant effect on muscle recovery in athletes at the intensity and irradiation parameters used in the present study. Further research using different parameters is required to determine how LEDT may contribute to post-exercise recovery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Joint Cooling does not Hinder Athletic Performance during High-intensity Intermittent Exercise.

    Science.gov (United States)

    Kim, H; Lee, D; Choi, H-M; Park, J

    2016-07-01

    We examined the effects of ankle and knee joint cooling on 20-m sprint times and maximal vertical jump heights during high-intensity intermittent exercise. 21 healthy collegiate male basketball (n=14) and handball players (n=7) underwent 3 experimental sessions. Each session consisted of four 15-min quarters of high-intensity intermittent exercises including various intensities of 20-m shuttle running and jumping. A 20-min bilateral joint cooling (ankle, knee, or control-no cooling: in a counterbalanced order) was applied before quarters 1 and 3. After joint cooling, no warm-up activity other than the exercise protocol was given. The 20-m sprint times and maximal vertical jump heights in each experimental session were recorded at baseline (prior to quarter-1) and during each quarter. To test joint cooling effects over time, we performed 3×5 mixed model ANOVAs. Neither ankle nor knee joint cooling changed 20-m sprint times (F8,280=1.45; p=0.18) or maximal vertical jump heights (F8,280=0.76; p=0.64). However, a trend was observed in which joint cooling immediately decreased (quarters 1 and 3) but active warm-up for approximately 20 min improved 20-min sprint times (quarters 2 and 4). Our study suggests that athletic performance such as sprinting and jumping are not altered by joint cooling applied prior to or during high-intensity intermittent exercise.