WorldWideScience

Sample records for high allergoid doses

  1. Structural studies of novel glycoconjugates from polymerized allergens (allergoids) and mannans as allergy vaccines.

    Science.gov (United States)

    Manzano, Ana I; Javier Cañada, F; Cases, Bárbara; Sirvent, Sofia; Soria, Irene; Palomares, Oscar; Fernández-Caldas, Enrique; Casanovas, Miguel; Jiménez-Barbero, Jesús; Subiza, José L

    2016-02-01

    Immunotherapy for treating IgE-mediated allergies requires high doses of the corresponding allergen. This may result in undesired side effects and, to avoid them, hypoallergenic allergens (allergoids) polymerized with glutaraldehyde are commonly used. Targeting allergoids to dendritic cells to enhance cell uptake may result in a more effective immunotherapy. Allergoids coupled to yeast mannan, as source of polymannoses, would be suitable for this purpose, since mannose-binding receptors are expressed on these cells. Conventional conjugation procedures of mannan to proteins use oxidized mannan to release reactive aldehydes able to bind to free amino groups in the protein; yet, allergoids lack these latter because their previous treatment with glutaraldehyde. The aim of this study was to obtain allergoids conjugated to mannan by an alternative approach based on just glutaraldehyde treatment, taking advantage of the mannoprotein bound to the polymannose backbone. Allergoid-mannan glycoconjugates were produced in a single step by treating with glutaraldehyde a defined mixture of allergens derived from Phleum pratense grass pollen and native mannan (non-oxidized) from Saccharomyces cerevisae. Analytical and structural studies, including 2D-DOSY and (1)H-(13)C HSQC nuclear magnetic resonance spectra, demonstrated the feasibility of such an approach. The glycoconjugates obtained were polymers of high molecular weight showing a higher stability than the native allergen or the conventional allergoid without mannan. The allergoid-mannan glycoconjugates were hypoallergenic as detected by the IgE reactivity with sera from grass allergic patients, even with lower reactivity than conventional allergoid without mannan. Thus, stable hypoallergenic allergoids conjugated to mannan suitable for using in immunotherapy can be achieved using glutaraldehyde. In contrast to mannan oxidation, the glutaraldehyde approach allows to preserve mannoses with their native geometry, which may be

  2. Molecular fingerprinting of complex grass allergoids: size assessments reveal new insights in epitope repertoires and functional capacities.

    Science.gov (United States)

    Starchenka, S; Bell, A J; Mwange, J; Skinner, M A; Heath, M D

    2017-01-01

    Subcutaneous allergen immunotherapy (SCIT) is a well-documented treatment for allergic disease which involves injections of native allergen or modified (allergoid) extracts. The use of allergoid vaccines is a growing sector of the allergy immunotherapy market, associated with shorter-course therapy. The aim of this study was the structural and immunological characterisation of group 1 (Lol p 1) IgG-binding epitopes within a complex mix grass allergoid formulation containing rye grass. HP-SEC was used to resolve a mix grass allergoid preparation of high molecular weight into several distinct fractions with defined molecular weight and elution profiles. Allergen verification of the HP-SEC allergoid fractions was confirmed by mass spectrometry analysis. IgE and IgG immunoreactivity of the allergoid preparations was explored and Lol p 1 specific IgG-binding epitopes mapped by SPOT synthesis technology (PepSpot™) with structural analysis based on a Lol p 1 homology model. Grass specific IgE reactivity of the mix grass modified extract (allergoid) was diminished in comparison with the mix grass native extract. A difference in IgG profiles was observed between an intact mix grass allergoid preparation and HP-SEC allergoid fractions, which indicated enhancement of accessible reactive IgG epitopes across size distribution profiles of the mix grass allergoid formulation. Detailed analysis of the epitope specificity showed retention of six Lol p 1 IgG-binding epitopes in the mix grass modified extract. The structural and immunological changes which take place following the grass allergen modification process was further unravelled revealing distinct IgG immunological profiles. All epitopes were mapped on the solvent exposed area of Lol p 1 homology model accessible for IgG binding. One of the epitopes was identified as an 'immunodominant' Lol p 1 IgG-binding epitope (62-IFKDGRGCGSCFEIK-76) and classified as a novel epitope. The results from this study support the concept

  3. Artemisia vulgaris pollen allergoids digestibility in the simulated conditions of the gastrointestinal tract

    Directory of Open Access Journals (Sweden)

    RATKO M. JANKOV

    2006-09-01

    Full Text Available Chemically modified allergens (allergoids have found use in both traditional and novel forms of immunotherapy of allergic disorders. Novel forms of immunotherapy include local allergen delivery, via the gastrointestinal tract. This study conveys the gastrointestinal stability of three types ofmugwort pollen allergoids under simulated conditions of the gut. Allergoids of the pollen extract of Artemisia vulgaris were obtained by means of potassium cyanate, succinic and maleic anhydride. Gastrointestinal tract conditions (saliva, and gastric fluid were simulated in accordance with the EU Pharmacopoeia. The biochemical and immunochemical properties of the derivatives following exposure to different conditions were monitored by determining the number of residual amino groups with 2,4,6-trinitrobenzenesulfonic acid, SDS PAGE, immunoblotting and inhibition of mugwort-specific IgE. Exposure to saliva fluid for 2 min did not influence the biochemical and immunochemical properties of the derivatives. In the very acidic conditions of the simulated gastric fluid, the degree of demaleylation and desuccinylation, even after 4 h exposure, was low, ranging from 10 to 30 %. The digestion patterns with pepsin proceeded rapidly in both the unmodified and modified samples. In all four cases, a highly resistant IgE-binding protein theMwof which was about 28 – 35 kD, was present. Within the physiological conditions, no new IgE binding epitopes were revealed, as demonstrated by immunoblot and CAP inhibition of the mugwort specific IgE binding. An important conclusion of this study is the stability of the modified derivatives in the gastrointestinal tract of patients, within physiological conditions. The means that they are suitable for use inmuch higher concentrations in local forms of immunotherapy than unmodified ones.

  4. Adjuvant effects of aluminium hydroxide-adsorbed allergens and allergoids - differences in vivo and in vitro.

    Science.gov (United States)

    Heydenreich, B; Bellinghausen, I; Lund, L; Henmar, H; Lund, G; Adler Würtzen, P; Saloga, J

    2014-06-01

    Allergen-specific immunotherapy (SIT) is a clinically effective therapy for immunoglobulin (Ig)E-mediated allergic diseases. To reduce the risk of IgE-mediated side effects, chemically modified allergoids have been introduced. Furthermore, adsorbance of allergens to aluminium hydroxide (alum) is widely used to enhance the immune response. The mechanisms behind the adjuvant effect of alum are still not completely understood. In the present study we analysed the effects of alum-adsorbed allergens and allergoids on their immunogenicity in vitro and in vivo and their ability to activate basophils of allergic donors. Human monocyte derived dendritic cells (DC) were incubated with native Phleum pratense or Betula verrucosa allergen extract or formaldehyde- or glutaraldehyde-modified allergoids, adsorbed or unadsorbed to alum. After maturation, DC were co-cultivated with autologous CD4(+) T cells. Allergenicity was tested by leukotriene and histamine release of human basophils. Finally, in-vivo immunogenicity was analysed by IgG production of immunized mice. T cell proliferation as well as interleukin (IL)-4, IL-13, IL-10 and interferon (IFN)-γ production were strongly decreased using glutaraldehyde-modified allergoids, but did not differ between alum-adsorbed allergens or allergoids and the corresponding unadsorbed preparations. Glutaraldehyde modification also led to a decreased leukotriene and histamine release compared to native allergens, being further decreased by adsorption to alum. In vivo, immunogenicity was reduced for allergoids which could be partly restored by adsorption to alum. Our results suggest that adsorption of native allergens or modified allergoids to alum had no consistent adjuvant effect but led to a reduced allergenicity in vitro, while we observed an adjuvant effect regarding IgG production in vivo.

  5. Mite allergoids coupled to nonoxidized mannan from Saccharomyces cerevisae efficiently target canine dendritic cells for novel allergy immunotherapy in veterinary medicine.

    Science.gov (United States)

    Soria, Irene; Alvarez, Javier; Manzano, Ana I; López-Relaño, Juan; Cases, Bárbara; Mas-Fontao, Ana; Cañada, F Javier; Fernández-Caldas, Enrique; Casanovas, Miguel; Jiménez-Barbero, Jesús; Palomares, Oscar; Viñals-Flórez, Luis M; Subiza, José L

    2017-08-01

    We have recently reported that grass pollen allergoids conjugated with nonoxidized mannan of Saccharomyces cerevisae using glutaraldehyde results in a novel hypoallergenic mannan-allergen complex with improved properties for allergen vaccination. Using this approach, human dendritic cells show a better allergen uptake and cytokine profile production (higher IL-10/IL-4 ratio) for therapeutic purposes. Here we aim to address whether a similar approach can be extended to dogs using canine dendritic cells. Six healthy Spanish Greyhound dogs were used as blood donors to obtain canine dendritic cells (DC) derived from peripheral blood monocytes. Allergens from Dermatophagoides farinae mite were polymerized and conjugated with nonoxidized mannan. Nuclear magnetic resonance (NMR), gel electrophoresis (SDS-PAGE), immunoblotting and IgE-ELISA inhibition studies were conducted to evaluate the main characteristics of the allergoid obtained. Mannan-allergen conjugate and controls were assayed in vitro for canine DC uptake and production of IL-4 and IL-10. The results indicate that the conjugation of D. farinae allergens with nonoxidized mannan was feasible using glutaraldehyde. The resulting product was a polymerized structure showing a high molecular weight as detected by NMR and SDS-PAGE analysis. The mannan-allergen conjugate was hypoallergenic with a reduced reactivity with specific dog IgE. An increase in both allergen uptake and IL-10/IL-4 ratio was obtained when canine DCs were incubated with the mannan-allergen conjugate, as compared with the control allergen preparations (unmodified D. farinae allergens and oxidized mannan-allergen conjugate). We conclude that hypoallergenic D. farinae allergens coupled to nonoxidized mannan is a novel allergen preparation suitable for canine allergy immunotherapy targeting dendritic cells. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Tolerance induction after specific immunotherapy with pollen allergoids adjuvanted by monophosphoryl lipid A in children.

    Science.gov (United States)

    Rosewich, M; Schulze, J; Eickmeier, O; Telles, T; Rose, M A; Schubert, R; Zielen, S

    2010-06-01

    Specific immunotherapy (SIT) is a well-established and clinically effective treatment for allergic diseases. A pollen allergoid formulated with the T helper type 1 (Th1)-inducing adjuvant monophosphoryl lipid A (MPL) facilitates short-term SIT. Little is known about mechanisms of tolerance induction in this setting. In a prospective study, 34 patients allergic to grass pollen (25 male, nine female, median age 10.2 years) received a total of 44 SIT courses (20 in the first, 24 in the second) with MPL-adjuvanted pollen allergoids. Immunogenicity was measured by levels of specific immunoglobulin G (IgG(grass)) and IgG4(grass) by antibody blocking properties on basophil activation, and by induction of CD4(+), CD25(+) and forkhead box P3 (FoxP3(+)) regulatory T cells (T(reg)). Specific IgG and IgG4 levels increased only slightly in the first year of SIT. In the second year these changes reached significance (P adjuvant MPL needs at least two courses to establish tolerance.

  7. 11 Efficacy and Tolerability of HDM Injective Immunotherapy With Monomeric Allergoid

    Science.gov (United States)

    Compalati, Enrico; Atzeni, Isabella; Cabras, Sergio; Fancello, Paolo; Gaspardini, Giulio; Longo, Rocco; Patella, Vincenzo; Tore, Giorgio

    2012-01-01

    Background Subcutaneous immunotherapy (SCIT) is an effective treatment of respiratory allergy and carbamylated monomeric allergoids (monoids), by virtue of their reduced IgE-binding activity, resulted clinically safe by sublingual administration. Purpose of this study was to investigate the efficacy and tolerability of immunotherapy with house dust mites (HDM) monoid administered by injective route in patients with allergic rhinoconjunctivitis (AR). Methods A preparation of 0.70 mL of 10 BU/mL containing modified extract with 50% Dermatophagoides pteronyssinus and 50% Dermatophagoides farinae (amount of major allergen: 4 μg of group 1 per milliliter) was delivered monthly for 12 months, following a 5-week build-up induction phase (0.10–0.20–0.30–0.50–0.70 mL), to 58 patients (60% males, mean age 25.1 ± 12.7) suffering from AR due to mites for at least 2 years, whereas 60 patients with similar baseline characteristics were observed as controls. All patients were allowed to assume traditional drug therapy for their condition. At the end of the study changes from baseline in symptoms scores, in number of days with drug assumption, in severity of AR (according to ARIA classification) were compared between the 2 groups; moreover an overall assessment of clinical efficacy and tolerability was based on patients' and physicians' judgements (unsatisfactory, mild, good, optimal). Results In respect to baseline both groups showed, after 1 year, an improvement in symptoms score (P < 0.001) with a significant difference in favour of SCIT group (P < 0.05). Days of drug intake were significantly lower in patients receiving SCIT (P < 0.05). The number of patients with severe AR decreased in the first group while no variation was observed in controls. The subjective clinical overall assessment was optimal in 31 cases and good in 24 according to physicians' and patients' judgements; similarly 38 patients judged tolerability as optimal and 18 as good, whereas according to

  8. Pharmacokinetically guided dosing of (high-dose) chemotherapeutic agents

    NARCIS (Netherlands)

    Attema-de Jonge, M.E. (Milly Ellen)

    2004-01-01

    Due to variation in drug distribution, metabolism and elimination processes between patients, systemic exposure to chemotherapeutic agents may be highly variable from patient to patient after administration of similar doses. This pharmacokinetic variability may explain in part the large variability

  9. IgG binding of mugwort pollen allergens and allergoids exposed to simulated gastrointestinal conditions measured by a self-developed ELISA test

    Directory of Open Access Journals (Sweden)

    RATKO M. JANKOV

    2004-07-01

    Full Text Available This study considers the influence of exposure to simulated gastrointestinal conditions (saliva, gut, intestine and acidic conditions of the gut on IgG binding of unmodified allergens and three types of LMW allergoids of Artemisia vulgaris pollen extract obtained by means of potassium cyanate, succinic and maleic anhydride. It also concerns the optimization of a self-developed ELISA assay for comparison of the specific IgG binding of mugwort pollen extract and modified mugwort pollen derivatives. The ELISA was conducted with a mugwort pollen extract coupled to the plate, using the sera from 12 mugwort-pollen allergic patients. The exposure to saliva fluid for 2 min did not influence the IgG binding properties of allergens and allergoids. Exposure of mugwort pollen allergens and LMW allergoids to the acidic conditions of the gut did not dramatically change their IgG binding properties. By exposing mugwort pollen extract and LMW derivatives to the SGF conditions for 1 h, the percent of IgG binding epitopes was reduced to a half of its starting value in the extract and to about 30 % in all the allergoid samples. After prolonged exposure only the carbamyl derivative showed reduced IgG binding. Changes of the IgG binding potential of all four samples after exposure in SIF followed a similar pattern.

  10. The adsorption of allergoids and 3-O-desacyl-4'-monophosphoryl lipid A (MPL®) to microcrystalline tyrosine (MCT) in formulations for use in allergy immunotherapy.

    Science.gov (United States)

    Bell, A J; Heath, M D; Hewings, S J; Skinner, M A

    2015-11-01

    Infectious disease vaccine potency is affected by antigen adjuvant adsorption. WHO and EMA guidelines recommend limits and experimental monitoring of adsorption in vaccines and allergy immunotherapies. Adsorbed allergoids and MPL® in MATA-MPL allergy immunotherapy formulations effectively treat IgE mitigated allergy. Understanding vaccine antigen adjuvant adsorption allows optimisation of potency and should be seen as good practice; however current understanding is seldom applied to allergy immunotherapies. The allergoid and MPL® adsorption to MCT in MATA-MPL allergy immunotherapy formulations was experimental determination using specific allergen IgE allerginicity and MPL® content methods. Binding forces between MPL® and MCT were investigated by competition binding experiments. MATA-MPL samples with different allergoids gave results within 100-104% of the theoretical 50μg/mL MPL® content. Unmodified drug substance samples showed significant desirable IgE antigenicity, 1040-170 QAU/mL. MATA-MPL supernatant samples with different allergoids gave results of ≤2 μg/mL MPL® and ≤0.1-1.4 QAU/mL IgE antigenicity, demonstrating approximately ≥96 & 99% adsorption respectively. Allergoid and MPL® adsorption in different MATA-MPL allergy immunotherapy formulations is consistent and meets guideline recommendations. MCT formulations treated to disrupt electrostatic, hydrophobic and ligand exchange interactions, gave an MPL® content of ≤2 μg/mL in supernatant samples. MCT formulations treated to disrupt aromatic interactions, gave an MPL® content of 73-92 μg/mL in supernatant samples. MPL® adsorption to l-tyrosine in MCT formulations is based on interactions between the 2-deoxy-2-aminoglucose backbone on MPL® and aromatic ring of l-tyrosine in MCT, such as C-H⋯π interaction. MCT could be an alternative adjuvant depot for some infectious disease antigens.

  11. Depigmented Allergoids Reveal New Epitopes with Capacity to Induce IgG Blocking Antibodies

    Directory of Open Access Journals (Sweden)

    M. Angeles López-Matas

    2013-01-01

    Full Text Available Background. The synthesis of allergen-specific blocking IgGs that interact with IgE after allergen immunotherapy (SIT has been related to clinical efficacy. The objectives were to investigate the epitope specificity of IgG-antibodies induced by depigmented-polymerized (Dpg-Pol allergoids and unmodified allergen extracts, and examine IgE-blocking activity of induced IgG-antibodies. Methods. Rabbits were immunized with native and Dpg-Pol extracts of birch pollen, and serum samples were obtained. Recognition of linear IgG-epitopes of Bet v 1 and Bet v 2 and the capacity of these IgG-antibodies to block binding of human-IgE was determined. Results. Serum from rabbits immunized with native extracts recognised 11 linear epitopes from Bet v 1, while that from Dpg-Pol-immunized animals recognised 8. For Bet v 2, 8 epitopes were recognized by IgG from native immunized animals, and 9 from Dpg-Pol immunized one. Dpg-Pol and native immunized serum did not always recognise the same epitopes, but specific-IgG from both could block human-IgE binding sites for native extract. Conclusions. Depigmented-polymerized birch extract stimulates the synthesis of specific IgG-antibodies which recognize common but also novel epitopes compared with native extracts. IgG-antibodies induced by Dpg-Pol effectively inhibit human-IgE binding to allergens which may be part of the mechanism of action of SIT.

  12. High-Dose Phenobarbital for Ohtahara Syndrome

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2002-05-01

    Full Text Available Oral high-dose phenobarbital therapy was effective in the control of tonic spasms in a 1 month-old-infant with early infantile epileptic encephalopathy with suppression bursts (Ohtahara syndrome treated at Tokyo Metropolitan Hachioji Children’s Hospital, Tokyo, Japan.

  13. [Hopes of high dose-rate radiotherapy].

    Science.gov (United States)

    Fouillade, Charles; Favaudon, Vincent; Vozenin, Marie-Catherine; Romeo, Paul-Henri; Bourhis, Jean; Verrelle, Pierre; Devauchelle, Patrick; Patriarca, Annalisa; Heinrich, Sophie; Mazal, Alejandro; Dutreix, Marie

    2017-04-01

    In this review, we present the synthesis of the newly acquired knowledge concerning high dose-rate irradiations and the hopes that these new radiotherapy modalities give rise to. The results were presented at a recent symposium on the subject. Copyright © 2017. Published by Elsevier Masson SAS.

  14. High-dose neutron detector project update

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-10

    These are the slides for a progress review meeting by the sponsor. This is an update on the high-dose neutron detector project. In summary, improvements in both boron coating and signal amplification have been achieved; improved boron coating materials and procedures have increase efficiency by ~ 30-40% without the corresponding increase in the detector plate area; low dead-time via thin cell design (~ 4 mm gas gaps) and fast amplifiers; prototype PDT 8” pod has been received and testing is in progress; significant improvements in efficiency and stability have been verified; use commercial PDT 10B design and fabrication to obtain a faster path from the research to practical high-dose neutron detector.

  15. High-dose erythropoietin for tissue protection

    DEFF Research Database (Denmark)

    Lund, Anton; Lundby, Carsten; Olsen, Niels Vidiendal

    2014-01-01

    BACKGROUND: The discovery of potential anti-apoptotic and cytoprotective effects of recombinant human erythropoietin (rHuEPO) has led to clinical trials investigating the use of high-dose, short-term rHuEPO therapy for tissue protection in conditions such as stroke and myocardial infarction....... Experimental studies have been favourable, but the clinical efficacy has yet to be validated. MATERIALS AND METHODS: We have reviewed clinical studies regarding the use of high-dose, short-term rHuEPO therapy for tissue protection in humans with the purpose to detail the safety and efficacy of r...... no effect of rHuEPO therapy on measures of tissue protection. Five trials including 1025 patients reported safety concerns in the form of increased mortality or adverse event rates. No studies reported reduced mortality. CONCLUSIONS: Evidence is sparse to support a tissue-protective benefit of r...

  16. High-dose neutron detector project update

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-10

    These are the slides for a progress review meeting by the sponsor. This is an update on the high-dose neutron detector project. In summary, improvements in both boron coating and signal amplification have been achieved; improved boron coating materials and procedures have increased efficiency by ~ 30-40% without the corresponding increase in the detector plate area; low dead-time via thin cell design (~ 4 mm gas gaps) and fast amplifiers; prototype PDT 8” pod has been received and testing is in progress; significant improvements in efficiency and stability have been verified; use commercial PDT 10B design and fabrication to obtain a faster path from the research to practical high-dose neutron detector.

  17. Amphotericin B for cryptococcal meningitis in HIV positive patients: Low dose versus high dose

    Directory of Open Access Journals (Sweden)

    Rajeshwari S

    2007-01-01

    Full Text Available Aim: To compare the safety and efficacy of low dose vs high dose of amphotericin B in cryptococcal meningitis associated with HIV infection. Materials and Methods: Retrospective data of patients admitted with clinical diagnosis with or without microbiological evidence of cryptococcal meningitis was collected from Jan 2000-Mar 2006. Patients′ details were collected in a proforma which included patient′s age, weight, signs and symptoms of disease and microbiological report (blood and CSF analysis. Data also included coexisting disease; concomitant medications taken along with amphotericin B. Adverse drug reactions which occurred during the period of treatment were recorded. Patients were grouped as low dose group and high dose group depending on the dose of amphotericin B given for the treatment of cryptococcal meningitis. Patients who received amphotericin B at doses of 0.33 to 0.64 mg/kg body weight per day were categorized under low dose group and patients who received amphotericin B at doses of 0.7 to 1.1 mg/kg/day were categorized under high dose group. All data were pooled and analyzed between the groups using chi square test. Result: Total number of patients included in the study were 38, 26 in the low dose group and 12 in the high dose group. In the low dose group, 20 were males and six were females, in the high dose group eight were males and four were females. The commonest underlying diseases were tuberculosis (17 in low dose group, nine in high dose group, Pneumocystis carinii (jeroveci pneumonia (16 in low dose group, seven in high dose group and oral candidiasis (eight in low dose group, seven in high dose group, Toxoplasmosis (three in low dose group, one in high dose group, hypertension (1 in group A and diabetes mellitus (1 in group B. Concomitant medication received along with amphotericin B for coexisting diseases in both the groups were antitubercular therapy, cotrimoxazole, antiviral therapy and premedications such as

  18. High dose insulin in toxic cardiogenic shock.

    Science.gov (United States)

    Holger, Joel S; Engebretsen, Kristin M; Marini, John J

    2009-04-01

    To report the successful use of high dose insulin (HDI) in previously unreported insulin dosing ranges in a patient with severe myocardial toxicity due to an amitriptyline and citalopram overdose. A 65-year-old female presented in respiratory arrest, which was followed by bradycardic pulseless electrical activity after ingesting multiple medications. After a prolonged resuscitation, the patient was maintained only on infusions of norepinephrine (40 mcg/min), vasopressin (4 units/h), insulin (80 units/h), and sodium bicarbonate. Due to a deteriorating clinical condition and limited prognosis, the insulin infusion was titrated incrementally upwards to 600 units/h (6 units/kg/h) over a 5 h time period while simultaneously completely weaning off both vasopressors. She developed brisk pulses and warm extremities, and her cardiac output nearly tripled. After 2 days of stabilization the insulin was slowly tapered, and the patient recovered. HDI as a single cardiovascular agent significantly improved clinical and cardiovascular parameters after the failure of vasopressor therapy in severe cardiovascular toxicity. Higher doses of insulin than previously recommended may be needed in toxic poisonings when severe myocardial depression is present.

  19. The application of high dose food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bruyn, I. De [Atomic Energy Corporation of South Africa LTD, Building 2000, P.O. Box 582, Pretoria 0001, (South Africa)

    1997-12-31

    During the 1950`s to end 1970`s the United States Army developed the basic methodology to produce shelf stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive `dried cooked` taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 25 to 45 kGy (depending on the product) at a temperature of between -20 and -40 Centigrade to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions. The product can be guaranteed for more than two years as long as the integrity of the packaging is maintained. (Author)

  20. Evaluation of Rectal Dose During High-Dose-Rate Intracavitary Brachytherapy for Cervical Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sha, Rajib Lochan [Department of Radiation Physics, Indo-American Cancer Institute and Research Centre, Hyderabad (India); Department of Physics, Osmania University, Hyderabad (India); Reddy, Palreddy Yadagiri [Department of Physics, Osmania University, Hyderabad (India); Rao, Ramakrishna [Department of Radiation Physics, MNJ Institute of Oncology and Regional Cancer Center, Hyderabad (India); Muralidhar, Kanaparthy R. [Department of Radiation Physics, Indo-American Cancer Institute and Research Centre, Hyderabad (India); Kudchadker, Rajat J., E-mail: rkudchad@mdanderson.org [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2011-01-01

    High-dose-rate intracavitary brachytherapy (HDR-ICBT) for carcinoma of the uterine cervix often results in high doses being delivered to surrounding organs at risk (OARs) such as the rectum and bladder. Therefore, it is important to accurately determine and closely monitor the dose delivered to these OARs. In this study, we measured the dose delivered to the rectum by intracavitary applications and compared this measured dose to the International Commission on Radiation Units and Measurements rectal reference point dose calculated by the treatment planning system (TPS). To measure the dose, we inserted a miniature (0.1 cm{sup 3}) ionization chamber into the rectum of 86 patients undergoing radiation therapy for cervical carcinoma. The response of the miniature chamber modified by 3 thin lead marker rings for identification purposes during imaging was also characterized. The difference between the TPS-calculated maximum dose and the measured dose was <5% in 52 patients, 5-10% in 26 patients, and 10-14% in 8 patients. The TPS-calculated maximum dose was typically higher than the measured dose. Our study indicates that it is possible to measure the rectal dose for cervical carcinoma patients undergoing HDR-ICBT. We also conclude that the dose delivered to the rectum can be reasonably predicted by the TPS-calculated dose.

  1. High-Dose Statins Boost Survival

    Science.gov (United States)

    ... atorvastatin (Lipitor) or 20 to 40 mg of rosuvastatin (Crestor) daily. Examples of moderate doses include 10 to ... of Lipitor and 5 to 10 mg of Crestor, the study reported. Unlike some previous studies, this ...

  2. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y., E-mail: yingchen29@yahoo.com.cn [Department of Radiation Toxicology and Oncology, Beijing Institute of Radiation Medicine, 27 Taiping Road, Haidian District, Beijing 100850 (China); Yan, X.K. [Department of Radiation Toxicology and Oncology, Beijing Institute of Radiation Medicine, 27 Taiping Road, Haidian District, Beijing 100850 (China); Department of Radiation Safety, Beijing Institute of Nuclear and Chemical Safety, 14 Guan-cun, Dongcheng District, Beijing 100077 (China); Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K. [Department of Radiation Toxicology and Oncology, Beijing Institute of Radiation Medicine, 27 Taiping Road, Haidian District, Beijing 100850 (China)

    2011-09-15

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of {sup 60}Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of {sup 60}Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0{sup -3}D{sup 2}. Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy {gamma}-irradiation from a supra-high dose {sup 60}Co gamma-ray accident.

  3. The transit dose component of high dose rate brachytherapy: Direct measurements and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Bastin, K.T.; Podgorsak, M.B.; Thomadsen, B.R. (Univ. of Wisconsin Hospitals and Clinics, Madison, WI (United States))

    1993-07-15

    The purpose was to measure the transit dose produced by a moving high dose rate brachytherapy source and assess its clinical significance. The doses produced from source movement during Ir-192 HDR afterloading were measured using calibrated thermoluminescent dosimeter rods. Transit doses at distances of 0.5-4.0 cm from an endobronchial applicator were measured using a Lucite phantom accommodating 1 x 1 x 6 mm thermoluminescent rods. Surface transit dose measurements were made using esophageal and endobronchial catheters, a gynecologic tandem, and an interstitial needle. No difference was detected in thermoluminescent dosimeter rod responses to 4 MV and Ir-192 spectra (427 nC/Gy) in a range of dose between 2 and 300 cGy. The transit dose at 0.5 cm from an endobronchial catheter was 0.31 cGy/(Curie-fraction) and followed an inverse square fall-off with increasing distance. Surface transit doses ranged from 0.38 cGy/(Curie-fraction) for an esophageal catheter to 1.03 cGy/(Curie-fraction) for an endobronchial catheter. Source velocity is dependent on the interdwell distance and varies between 220-452 mm/sec. A numeric algorithm was developed to calculate total transit dose, and was based on a dynamic point approximation for the moving high dose rate source. This algorithm reliably predicted the empirical transit doses and demonstrated that total transit dose is dependent on source velocity, number of fractions, and source activity. Surface transit doses are dependent on applicator diameter and wall material and thickness. Total transit doses within or outside the desired treatment volume are typically <100 cGy, but may exceed 200 cGy when using a large number of fractions with a high activity source. 9 refs., 8 figs., 1 tab.

  4. High dose radiotherapy for pituitary tumours

    Energy Technology Data Exchange (ETDEWEB)

    Mead, K.W. (Queensland Radium Inst., Herston (Australia))

    1981-11-01

    The results of treatment of 120 pituitary tumours are presented. Based on this experience operable chromophobe adenomas are now treated with 5,000 rads in 4 weeks and inoperable ones receive an additional central dose to 7,500 rads. Pituitary Cushing's tumours are given 10,000 rads in 5 weeks using small fields and acromegalics 5,000 rads to the whole sella and 7,500 to its lower half. The absence of complications at these dose levels is attributed to the use of small fields and the precise application of treatment.

  5. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  6. Statistical behavior of high doses in medical radiodiagnosis; Comportamento estatistico das altas doses em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana Elisa, E-mail: adrianaebarboza@gmail.com, E-mail: elisa@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  7. Investigating quartz optically stimulated luminescence dose-response curves at high doses

    Energy Technology Data Exchange (ETDEWEB)

    Lowick, Sally E., E-mail: lowick@geo.unibe.c [Institut fuer Geologie, Universitaet Bern, Baltzerstrasse 1-3, 3012 Bern (Switzerland); Preusser, Frank [Institut fuer Geologie, Universitaet Bern, Baltzerstrasse 1-3, 3012 Bern (Switzerland); Wintle, Ann G. [Institute of Geography and Earth Sciences, Aberystwyth University, AberystwythSY23 3DB (United Kingdom)

    2010-10-15

    Despite the general expectation that optically stimulated luminescence (OSL) growth should be described by a simple saturating exponential function, an additional high dose component is often reported in the dose response of quartz. Although often reported as linear, it appears that this response is the early expression of a second saturating exponential. While some studies using equivalent doses that fall in this high dose region have produced ages that correlate well with independent dating, others report that it results in unreliable age determinations. Two fine grain sedimentary quartz samples that display such a response were used to investigate the origin of this additional high dose component: three experiments were conducted to examine their dose-response up to >1000 Gy. The high dose rates provided by laboratory irradiation were found not to induce a sensitivity change in the response to a subsequent test dose, with the latter not being significantly different from those generated following naturally acquired doses. The relative percentage contributions of the fast and medium OSL components remained fixed throughout the dose-response curve, suggesting that the electron traps that give rise to the initial OSL do not change with dose. An attempt was made to investigate a change in luminescence centre recombination probability by monitoring the depletion of the '325 {sup o}C' thermoluminescence (TL) during the optical stimulation that would result in depletion of the OSL signal. The emissions measured through both the conventional ultraviolet (UV), and a longer wavelength violet/blue (VB) window, displayed similar relative growth with dose, although it was not possible to resolve the origin of the VB emissions. No evidence was found to indicate whether the additional component at high doses occurs naturally or is a product of laboratory treatment. However, it appears that these samples display an increased sensitivity of quartz OSL to high doses

  8. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  9. Fertility of Tall Girls Treated with High-Dose Estrogen, a Dose-Response Relationship

    NARCIS (Netherlands)

    Hendriks, A. E. J.; Drop, S. L. S.; Laven, J. S. E.; Boot, A. M.

    2012-01-01

    Context: High-dose estrogen treatment to reduce final height of tall girls increases their risk for infertility in later life. Objective: The aim was to study the effect of estrogen dose on fertility outcome of these women. Design/Setting: We conducted a retrospective cohort study of university hosp

  10. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    2005-01-01

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with high

  11. Pharmacogenetics and Pharmacokinetics in high-dose alkylating chemotherapy

    NARCIS (Netherlands)

    Ekhart, G.C. (Corine)

    2008-01-01

    High-dose chemotherapy in combination with peripheral blood progenitor cell transplantation has been developed as a possible curative treatment modality in several solid tumours. A frequently used high-dose regimen in the Netherlands is the CTC regimen, which is a 4-day course of cyclophosphamide, t

  12. High-resolution low-dose scanning transmission electron microscopy.

    Science.gov (United States)

    Buban, James P; Ramasse, Quentin; Gipson, Bryant; Browning, Nigel D; Stahlberg, Henning

    2010-01-01

    During the past two decades instrumentation in scanning transmission electron microscopy (STEM) has pushed toward higher intensity electron probes to increase the signal-to-noise ratio of recorded images. While this is suitable for robust specimens, biological specimens require a much reduced electron dose for high-resolution imaging. We describe here protocols for low-dose STEM image recording with a conventional field-emission gun STEM, while maintaining the high-resolution capability of the instrument. Our findings show that a combination of reduced pixel dwell time and reduced gun current can achieve radiation doses comparable to low-dose TEM.

  13. High dose brachytherapy in pediatric oncology; Braquiterapia com alta taxa de dose em oncologia pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Ferrigno, Robson; Codjaian, Osanna Esther; Novaes, Paulo Eduardo R.S.; Trippe, Nivaldo [Fundacao Antonio Prudente, Sao Paulo, SP (Brazil). Hospital A.C. Camargo. Dept. de Radioterapia

    1995-05-01

    Brachytherapy is a kind of radiotherapy that has been used in the multidisciplinary approach of some pediatric tumors, such as soft tissue sarcomas of the extremities, head and neck and urogenital tract. Recent technological advances in this area lead to development of computerized high dose rate remote afterloading brachytherapy. This type of treatment has some advantages compared to low dose rate brachytherapy traditionally used. This article describes not only the characteristics and advantages of this kind of treatment, but also the preliminary results of the first seven children treated with high dose rate at the Hospital A.C.Camargo. (author) 10 refs., 8 figs.

  14. Accelerated Irradiations for High Dose Microstructures in Fast Reactor Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhijie [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-31

    The objective of this project is to determine the extent to which high dose rate, self-ion irradiation can be used as an accelerated irradiation tool to understand microstructure evolution at high doses and temperatures relevant to advanced fast reactors. We will accomplish the goal by evaluating phase stability and swelling of F-M alloys relevant to SFR systems at very high dose by combining experiment and modeling in an effort to obtain a quantitative description of the processes at high and low damage rates.

  15. High-dose dosimetry using natural silicate minerals

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Mendes, Leticia, E-mail: isatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina, E-mail: lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear; Barbosa, Renata F., E-mail: profcelta@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil). Departamento de Ciencias do Mar

    2015-07-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  16. Impact of surface curvature on dose delivery in intraoperative high-dose-rate brachytherapy.

    Science.gov (United States)

    Oh, Moonseong; Wang, Zhou; Malhotra, Harish K; Jaggernauth, Wainwright; Podgorsak, Matthew B

    2009-01-01

    In intraoperative high-dose-rate (IOHDR) brachytherapy, a 2-dimensional (2D) geometry is typically used for treatment planning. The assumption of planar geometry may cause serious errors in dose delivery for target surfaces that are, in reality, curved. A study to evaluate the magnitude of these errors in clinical practice was undertaken. Cylindrical phantoms with 6 radii (range: 1.35-12.5 cm) were used to simulate curved treatment geometries. Treatment plans were developed for various planar geometries and were delivered to the cylindrical phantoms using catheters inserted into Freiburg applicators of varying dimension. Dose distributions were measured using radiographic film. In comparison to the treatment plan (for a planar geometry), the doses delivered to prescription points were higher on the concave side of the geometry, up to 15% for the phantom with the smallest radius. On the convex side of the applicator, delivered doses were up to 10% lower for small treated areas (5 catheters). Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan is delivered with a curved applicator. Dose delivery errors arising from the use of planar treatment plans with curved applicators may be significant.

  17. High-Dose Vitamin D May Not Curb Kids' Colds

    Science.gov (United States)

    ... medlineplus.gov/news/fullstory_167275.html High-Dose Vitamin D May Not Curb Kids' Colds Study seems ... 18, 2017 (HealthDay News) -- When it comes to vitamin supplements, more is not always better, according to ...

  18. Patient-specific dose calculation methods for high-dose-rate iridium-192 brachytherapy

    Science.gov (United States)

    Poon, Emily S.

    In high-dose-rate 192Ir brachytherapy, the radiation dose received by the patient is calculated according to the AAPM Task Group 43 (TG-43) formalism. This table-based dose superposition method uses dosimetry parameters derived with the radioactive 192Ir source centered in a water phantom. It neglects the dose perturbations caused by inhomogeneities, such as the patient anatomy, applicators, shielding, and radiographic contrast solution. In this work, we evaluated the dosimetric characteristics of a shielded rectal applicator with an endocavitary balloon injected with contrast solution. The dose distributions around this applicator were calculated by the GEANT4 Monte Carlo (MC) code and measured by ionization chamber and GAFCHROMIC EBT film. A patient-specific dose calculation study was then carried out for 40 rectal treatment plans. The PTRAN_CT MC code was used to calculate the dose based on computed tomography (CT) images. This study involved the development of BrachyGUI, an integrated treatment planning tool that can process DICOM-RT data and create PTRAN_CT input initialization files. BrachyGUI also comes with dose calculation and evaluation capabilities. We proposed a novel scatter correction method to account for the reduction in backscatter radiation near tissue-air interfaces. The first step requires calculating the doses contributed by primary and scattered photons separately, assuming a full scatter environment. The scatter dose in the patient is subsequently adjusted using a factor derived by MC calculations, which depends on the distances between the point of interest, the 192Ir source, and the body contour. The method was validated for multicatheter breast brachytherapy, in which the target and skin doses for 18 patient plans agreed with PTRAN_CT calculations better than 1%. Finally, we developed a CT-based analytical dose calculation method. It corrects for the photon attenuation and scatter based upon the radiological paths determined by ray tracing

  19. High-dose vs low-dose oxytocin for labor augmentation: a systematic review.

    Science.gov (United States)

    Wei, Shu-Qin; Luo, Zhong-Cheng; Qi, Hui-Ping; Xu, Hairong; Fraser, William D

    2010-10-01

    The objective of this systematic review was to estimate the efficacy and safety of high-dose vs low-dose oxytocin for labor augmentation on the risk of cesarean section and on indicators of maternal and neonatal morbidity. We searched PubMed, MEDLINE, EMBASE, and the Cochrane Library for randomized clinical trials published until January 2010. Ten randomized clinical trials, including 5423 women, met the inclusion criteria. High-dose oxytocin was associated with a moderate decrease in the risk of cesarean section (relative risk [RR], 0.85; 95% confidence interval [CI], 0.75-0.97), a small increase in spontaneous vaginal delivery (RR, 1.07; 95% CI, 1.02-1.12), and a decrease in labor duration (mean difference: -1.54 hours, 95% CI, -2.44 to -0.64). While hyperstimulation was increased with high-dose oxytocin (RR, 1.91; 95% CI, 1.49-2.45), there was no evidence of an increase in maternal or neonatal morbidity. We conclude that high-dose oxytocin for labor augmentation is associated with a decrease in cesarean section and shortened labor. Copyright © 2010 Mosby, Inc. All rights reserved.

  20. High-dose neutron detector development

    Energy Technology Data Exchange (ETDEWEB)

    Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-01-14

    The development of advanced sustainable nuclear fuel cycles relying on used nuclear fuel is one of the key programs pursued by the DOE Office of Nuclear Energy to minimize waste generation, limit proliferation risk and maximize energy production using nuclear energy. Safeguarding of advanced nuclear fuel cycles is essential to ensure the safety and security of the nuclear material. Current non-destructive assay (NDA) systems typically employ fission chambers or 3He-based tubes for the measurement of used fuel. Fission chambers are capable of withstanding the high gamma-ray backgrounds; however, they provide very low detection efficiency on the order of 0.01%. To benefit from the additional information provided by correlated neutron counting [1] higher detection efficiencies are required. 3He-based designs allow for higher detection efficiencies; however, at the expense of slow signal rise time characteristics and higher sensitivity to the gamma-ray backgrounds. It is therefore desirable to evaluate and develop technologies with potential to exceed performance parameters of standard fission chamber-based or 3He-based detection systems currently used in the NDA instrumentation.

  1. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  2. Calcium carbonate as a possible dosimeter for high irradiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Negron M, A.; Ramos B, S.; Camargo R, C. [UNAM, Instituto de Ciencias Nucleares, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Uribe, R. M. [Kent State University, College of Technology, Kent OH (United States); Gomez V, V. [UNAM, Instituto de Quimica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Kobayashi, K., E-mail: negron@nucleares.unam.mx [Yokohama National University (Japan)

    2014-08-15

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  3. Spectroscopic gamma camera for use in high dose environments

    Science.gov (United States)

    Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Kometani, Yutaka; Suzuki, Yasuhiko; Umegaki, Kikuo

    2016-06-01

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  4. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  5. Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Granero, Domingo, E-mail: dgranero@eresa.com [Department of Radiation Physics, ERESA, Hospital General Universitario, 46014 Valencia (Spain); Perez-Calatayud, Jose [Radiotherapy Department, La Fe University and Polytechnic Hospital, Valencia 46026 (Spain); Vijande, Javier [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and IFIC (UV-CSIC), Paterna 46980 (Spain); Ballester, Facundo [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2014-02-15

    Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For

  6. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Directory of Open Access Journals (Sweden)

    Daniel G Zhang

    Full Text Available MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF and conventional flattened 6MV photon beams were used. High dose rate (HDR brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL would be needed.

  7. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Science.gov (United States)

    Zhang, Daniel G; Feygelman, Vladimir; Moros, Eduardo G; Latifi, Kujtim; Zhang, Geoffrey G

    2014-01-01

    MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd)-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF) and conventional flattened 6MV photon beams were used. High dose rate (HDR) brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL) would be needed.

  8. Remote Afterloading High Dose Rate Brachytherapy AMC EXPERIANCES

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Gyong; Chang, Hye Sook; Choi, Eun Kyong; Yi, Byong Yong [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1992-12-15

    Remote afterloading high dose rate brachytherapy(HDRB) is a new technology and needs new biological principle for time and dose schedule. Here, authors attempt to evaluate the technique and clinical outcome in 116 patients, 590 procedures performed at Asan Medical Center for 3 years. From Sep. 1985 to Aug 1992, 471 procedures of intracavitary radiation in 55 patients of cervical cancer and 26 of nasopharyngeal cancer, 79 intraluminal radiation in 12 of esophageal cancer, 11 of endobronchial cancer and 1 Klatskin tumor and 40 interstitial brachytherapy in 4 of breast cancer, 1 sarcoma and 1 urethral cancer were performed. Median follow-up was 7 months with range 1-31 months. All procedures except interstitial were performed under the local anesthesia and they were all well tolerated and completed the planned therapy except 6 patients. 53/58 patients with cervical cancer and 22/26 patients with nasopharynx cancer achieved CR. Among 15 patients with palliative therapy, 80% achieves palliation. We will describe the details of the technique and results in the text. To evaluate biologic effects of HDRB and optimal time/dose/fractionation schedule, we need longer follow-up. But authors feel that HDRB with proper fractionation schedule may yield superior results compared to the low dose rate brachytherapy considering the advantages of HDRB in safety factor for operator, better control of radiation dose and volume and patients comfort over the low dose brachytherapy.

  9. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  10. High-dose Helical Tomotherapy With Concurrent Full-dose Chemotherapy for Locally Advanced Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jee Suk [Department of Radiation Oncology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Wang, Michael L.C. [Department of Radiation Oncology, National Cancer Centre (Singapore); Koom, Woong Sub; Yoon, Hong In; Chung, Yoonsun [Department of Radiation Oncology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Song, Si Young [Department of Internal Medicine, Yonsei University College of Medicine, Seoul (Korea, Republic of); Seong, Jinsil, E-mail: jsseong@yuhs.ac [Department of Radiation Oncology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-08-01

    Purpose: To improve poor therapeutic outcome of current practice of chemoradiotherapy (CRT), high-dose helical tomotherapy (HT) with concurrent full-dose chemotherapy has been performed on patients with locally advanced pancreatic cancer (LAPC), and the results were analyzed. Methods and Materials: We retrospectively reviewed 39 patients with LAPC treated with radiotherapy using HT (median, 58.4 Gy; range, 50.8-59.9 Gy) and concomitant chemotherapy between 2006 and 2009. Radiotherapy was directed to the primary tumor with a 0.5-cm margin without prophylactic nodal coverage. Twenty-nine patients (79%) received full-dose (1000 mg/m{sup 2}) gemcitabine-based chemotherapy during HT. After completion of CRT, maintenance chemotherapy was administered to 37 patients (95%). Results: The median follow-up was 15.5 months (range, 3.4-43.9) for the entire cohort, and 22.5 months (range, 12.0-43.9) for the surviving patients. The 1- and 2-year local progression-free survival rates were 82.1% and 77.3%, respectively. Eight patients (21%) were converted to resectable status, including 1 with a pathological complete response. The median overall survival and progression-free survival were 21.2 and 14.0 months, respectively. Acute toxicities were acceptable with no gastrointestinal (GI) toxicity higher than Grade 3. Severe late GI toxicity ({>=}Grade 3) occurred in 10 patients (26%); 1 treatment-related death from GI bleeding was observed. Conclusion: High-dose helical tomotherapy with concurrent full-dose chemotherapy resulted in improved local control and long-term survival in patients with LAPC. Future studies are needed to widen the therapeutic window by minimizing late GI toxicity.

  11. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  12. Multifocal Electroretinography after High Dose Chloroquine Therapy for Malaria

    Directory of Open Access Journals (Sweden)

    Aline Correa de Carvalho

    2013-01-01

    Full Text Available Purpose: To investigate changes in multifocal electroretinography (mfERG parameters associated with high dose chloroquine therapy for treatment of malaria in the Amazonia region of Brazil. Methods: Forty-eight subjects who had received chloroquine treatment for single or multiple malaria infections with a cumulative dose ranging from 1,050 to 27,000mg were included. The control group consisted of 37 healthy aged-matched subjects. Data was collected on amplitude and implicit time of the N1, P1 and N2 waves in the central macular hexagon (R1 and in five concentric rings at different retinal eccentricities (R2-R6. Results: No significant difference was observed in any mfERG parameter between chloroquine treated patients and control subjects. A comparison with previous data obtained from patients with rheumatologic disorders in the same region of Brazil who had received larger cumulative doses of chloroquine and had displayed mfERG changes, indicated that retinal toxicity seems to be dependent on cumulative dose. Conclusion: Lack of mfERG changes in the current study suggests that intensive high dose chloroquine therapy for treatment of malaria is not associated with retinal toxicity.

  13. High-dose acetylcysteine in idiopathic pulmonary fibrosis.

    NARCIS (Netherlands)

    Demedts, M.; Behr, J.; Buhl, R.; Costabel, U.; Dekhuijzen, P.N.R.; Jansen, H.M.L.; MacNee, W.; Thomeer, M.; Wallaert, B.; Laurent, F.; Nicholson, A.G.; Verbeken, E.K.; Verschakelen, J.; Flower, C.D.; Capron, F.; Petruzzelli, S.; Vuyst, P. De; Bosch, J.M. van den; Rodriguez-Becerra, E.; Corvasce, G.; Lankhorst, I.L.M.; Sardina, M.; Montanari, M.

    2005-01-01

    BACKGROUND: Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS: We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily) add

  14. Oval pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    Hoogendijk, JE; Wokke, JHJ; de Visser, M

    2000-01-01

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Sis patients responded. Side effects w

  15. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth Carl)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  16. High dose corticosteroids in severe leptospirosis: a systematic review.

    Science.gov (United States)

    Rodrigo, Chaturaka; Lakshitha de Silva, Nipun; Goonaratne, Ravindi; Samarasekara, Keshinie; Wijesinghe, Indika; Parththipan, B; Rajapakse, Senaka

    2014-12-01

    The role of corticosteroids in the treatment of severe leptospirosis is unclear. The rationale for their use is that, in severe leptospirosis, there is a severe immunological response that is harmful to the host resulting in multi-organ dysfunction, which is potentially offset by the nonspecific immunosuppression of high dose steroids. We conducted a systematic review of studies that have assessed the use of high dose corticosteroids in patients with severe leptospirosis by searching MEDLINE and Scopus SciVerse without any language or time restrictions. We identified five studies, including one open randomized clinical trial, which had assessed the use of high dose steroids in severe leptospirosis. Four studies demonstrated a benefit of corticosteroids in treating severe disease with pulmonary involvement when administered early in the course of the disease, but these studies had several methodological constraints as highlighted in the text. Only the randomized controlled trial study showed that corticosteroids are ineffective and may increase the risk of nosocomial infections. There is no robust evidence to suggest that high dose corticosteroids are effective in severe leptospirosis, and a well-designed randomized clinical trial is needed to resolve this.

  17. High-dose acetylcysteine in idiopathic pulmonary fibrosis.

    NARCIS (Netherlands)

    Demedts, M.; Behr, J.; Buhl, R.; Costabel, U.; Dekhuijzen, P.N.R.; Jansen, H.M.L.; MacNee, W.; Thomeer, M.; Wallaert, B.; Laurent, F.; Nicholson, A.G.; Verbeken, E.K.; Verschakelen, J.; Flower, C.D.; Capron, F.; Petruzzelli, S.; Vuyst, P. De; Bosch, J.M. van den; Rodriguez-Becerra, E.; Corvasce, G.; Lankhorst, I.L.M.; Sardina, M.; Montanari, M.

    2005-01-01

    BACKGROUND: Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS: We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily) add

  18. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth Carl)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  19. High-dose acetylcysteine in idiopathic pulmonary fibrosis.

    NARCIS (Netherlands)

    Demedts, M.; Behr, J.; Buhl, R.; Costabel, U.; Dekhuijzen, P.N.R.; Jansen, H.M.L.; MacNee, W.; Thomeer, M.; Wallaert, B.; Laurent, F.; Nicholson, A.G.; Verbeken, E.K.; Verschakelen, J.; Flower, C.D.; Capron, F.; Petruzzelli, S.; Vuyst, P. De; Bosch, J.M. van den; Rodriguez-Becerra, E.; Corvasce, G.; Lankhorst, I.L.M.; Sardina, M.; Montanari, M.

    2005-01-01

    BACKGROUND: Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS: We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily)

  20. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Hideya [Toyonaka Municipal Hospital, Osaka (Japan); Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko [Osaka Univ., Suita (Japan). Graduate School of Medicine; Furukawa, Souhei; Kakimoto, Naoya [Osaka Univ., Suita (Japan). Graduate School of Dentistry

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  1. Brachytherapy for early oral tongue cancer: low dose rate to high dose rate.

    Science.gov (United States)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Furukawa, Souhei; Kakimoto, Naoya; Shimizutani, Kimishige; Inoue, Toshihiko

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n = 341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer.

  2. Impairment of memorization by high doses of pyridoxine in man.

    Science.gov (United States)

    Molimard, R; Marillaud, A; Paille, A; Le Devehat, C; Lemoine, A; Dougny, M

    1980-05-01

    Two controlled trials were performed successively to evaluate the effect of high doses of oral pyridoxine on brain performance in man. In trial I, medical students volunteered to take 100 mg, 500 mg of pyridoxine a day or placebo for 10 days. A digit coding test was performed before, and at the end of the treatment period and a third 15 days later. The improvement of performance from the first to the third test (learning effect) was significantly better in the placebo group than in the B6 treated groups. This could be attributed to memorization of skills. Trial II was performed in obese patients starting a low calorie diet in whom vitamins are routinely prescribed. Performance in a work recognition test and in a visual retention test was lower for the group receiving 1 g of pyridoxine a day. Thus, high doses of oral pyridoxine are likely to impair memorization in man. Disturbances of neuro-transmitter metabolism such as increase of GABA production might explain the effect. As the benefit of high doses of pyridoxine has not been well-documented and as the study has suggested that undesired effects may indeed exist, the widespread use of such doses is questionable.

  3. Hardening electronic devices against very high total dose radiation environments

    Science.gov (United States)

    Buchanan, B.; Shedd, W.; Roosild, S.; Dolan, R.

    1972-01-01

    The possibilities and limitations of hardening silicon semiconductor devices to the high neutron and gamma radiation levels and greater than 10 to the eighth power rads required for the NERVA nuclear engine development are discussed. A comparison is made of the high dose neutron and gamma hardening potential of bipolar, metal insulator semiconductors and junction field effect transistors. Experimental data is presented on device degradation for the high neutron and gamma doses. Previous data and comparisons indicate that the JFET is much more immune to the combined neutron displacement and gamma ionizing effects than other transistor types. Experimental evidence is also presented which indicates that p channel MOS devices may be able to meet the requirements.

  4. High-dose desvenlafaxine in outpatients with major depressive disorder.

    Science.gov (United States)

    Ferguson, James M; Tourian, Karen A; Rosas, Gregory R

    2012-09-01

    This study investigated the safety and efficacy of long-term treatment with high-dose desvenlafaxine (administered as desvenlafaxine succinate) in major depressive disorder (MDD). In this multicenter, open-label study, adult outpatients with MDD aged 18-75 were treated with flexible doses of desvenlafaxine (200-400 mg/d) for ≤ 1 year. Safety assessments included monitoring of treatment-emergent adverse events (TEAEs), patient discontinuations due to adverse events, electrocardiograms, vital signs, and laboratory determinations. The primary efficacy measure was mean change from baseline in the 17-item Hamilton Rating Scale for Depression [HAM-D(17)] total score. The mean daily desvenlafaxine dose range over the duration of the trial was 267-356 mg (after titration). The most frequent TEAEs in the safety population (n = 104) were nausea (52%) and headache (41%), dizziness (31%), insomnia (29%), and dry mouth (27%). All TEAEs were mild or moderate in severity. Thirty-four (33%) patients discontinued from the study because of TEAEs; nausea (12%) and dizziness (9%) were the most frequently cited reasons. The mean change in HAM-D(17) total score for the intent-to-treat population (n = 99) was -9.9 at the last on-therapy visit in the last-observation-carried-forward analysis and -14.0 at month 12 in the observed cases analysis. Conclusion High-dose desvenlafaxine (200-400 mg/d) was generally safe and effective in the long-term treatment of MDD.

  5. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  6. Gemcitabine radiosensitization after high-dose samarium for osteoblastic osteosarcoma.

    Science.gov (United States)

    Anderson, Peter M; Wiseman, Gregory A; Erlandson, Linda; Rodriguez, Vilmarie; Trotz, Barbara; Dubansky, Stephen A; Albritton, Karen

    2005-10-01

    Osteoblastic metastases and osteosarcoma can avidly concentrate bone-seeking radiopharmaceuticals. We sought to increase effectiveness of high-dose (153)Samarium ethylenediaminetetramethylenephosphonate (153Sm-EDTMP, Quadramet) on osteosarcomas using a radiosensitizer, gemcitabine. Fourteen patients with osteoblastic lesions were treated with 30 mCi/kg 153Sm-EDTMP. Gemcitabine was administered 1 day after samarium infusion. Residual total body radioactivity was within the safe range of 1 year, there have been no durable responses. Thus, although high-dose 153Sm-EDTMP + gemcitabine has moderate palliative activity (improved pain; radiologic responses) in this poor-risk population, additional measures of local and systemic control are required for durable control of relapsed osteosarcoma with osteoblastic lesions. The strategy of radioactive drug binding to a target followed by a radiosensitizer may provide synergy and improved response rate.

  7. Methodology of high dose research in medical radiodiagnostic; Metodologia de investigacao de doses elevadas em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana E.; Martins, Cintia P. de S., E-mail: ird@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations.

  8. Image-guided high dose rate endorectal brachytherapy.

    Science.gov (United States)

    Devic, Slobodan; Vuong, Té; Moftah, Belal; Evans, Michael; Podgorsak, Ervin B; Poon, Emily; Verhaegen, Frank

    2007-11-01

    Fractionated high dose rate endorectal brachytherapy (HDR-EBT) using CT-based treatment planning is an alternative method for preoperative down-sizing and down-staging of advanced rectal adeno-carcinomas. The authors present an image guidance procedure that was developed to ensure daily dose reproducibility for the four brachytherapy treatment fractions. Since the applicator might not be placed before each treatment fraction inside the rectal lumen in the same manner as it was placed during the 3D CT volume acquisition used for treatment planning, there is a shift along the catheter axis that may have to be performed. The required shift is determined by comparison of a daily radiograph with the treatment planning digitally-reconstructed radiograph (DRR). A procedure is developed for DRR reconstruction from the 3D data set used for the treatment planning, and two possible daily longitudinal shifts are illustrated: above and below the planning dose distribution. The authors also describe the procedure for rotational alignment illustrated on a clinical case. Reproduction of the treatment planned dose distribution on a daily basis is crucial for the success of fractionated 3D based brachytherapy treatments. Due to the cylindrical symmetry of the applicator used for preoperative HDR-EBT, two types of adjustments are necessary: applicator rotation and dwell position shift along the applicator's longitudinal axis. The impact of the longitudinal applicator shift prior to treatment delivery for 62 patients treated in our institution is also assessed.

  9. SU-E-T-315: The Change of Optically Stimulated Luminescent Dosimeters (OSLDs) Sensitivity by Accumulated Dose and High Dose

    Energy Technology Data Exchange (ETDEWEB)

    Han, S; Jung, H; Kim, M; Ji, Y; Kim, K [University of Science and Technology, Daejeon (Korea, Republic of); Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Choi, S; Park, S; Yoo, H [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Yi, C [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2014-06-01

    Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulated dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.

  10. High-dose irradiation of food; Hochdosisbestrahlung von Lebensmitteln

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, J.F.

    1999-07-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [German] Die im Rahmen des Projekts erteilten Auftraege betrafen nur solche Lebensmittel, die im Dosisbereich < 10 kGy bestrahlt waren, da der Bereich hoeherer Dosen durch die amerikanischen Untersuchungen abgedeckt war. Als das Joint FAO/IAEA/WHO Expert Committee on Food Irradiation (JECFI) 1980 in Genf tagte, um ueber die gesundheitliche Bewertung bestrahlter Lebensmittel zu beraten, waren jedoch die in den Vereinigten Staaten laufenden, sehr umfangreichen Langzeitversuche mit strahlensterilisiertem Haehnchenfleisch (Dosis 58 kGy) noch nicht abgeschlossen. Das Komitee beschraenkte sich daher auf die Bewertung der vom Internationalen Projekt vorgelegten Ergebnisse. Die Schlussfolgerung 'the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required'beendete die jahrzehntelange Debatte ueber die gesundheitliche Unbedenklichkeit von im niedrigen (bis 1 kGy) und mittleren (1 bis 10 k

  11. EPR/Homotaurine: A possible dosimetry system for high doses

    Energy Technology Data Exchange (ETDEWEB)

    Maghraby, A., E-mail: maghrabism@yahoo.com [National Institute of Standards (NIS) - Radiation Dosimetry Department - Tersa st. 12211 Giza, P.O. Box 136 (Egypt); Salama, E. [Physics Department, Faculty of Science, Ain Shams University, 11566 Cairo (Egypt); Mansour, A. [National Center for Radiation Research and Technology, Atomic Energy Authority, Nasr City, Cairo (Egypt)

    2011-12-11

    An EPR investigation of radiation induced radicals in Homotaurine revealed that there are two types of radicals produced after exposure to gamma radiation ({sup 60}Co). EPR spectra were recorded and analyzed; also the microwave power saturation curves for both radicals were studied. The effect of change in modulation amplitude on peak-to-peak signal height and line width was investigated; this is in addition to the evaluation of energy dependence parameters compared to soft tissue and alanine dosimeters. Response of Homotaurine to different radiation doses (0.5 kGy-50 kGy) was studied and found to follow a linear relationship. Radiation induced radicals in Homotaurine persisted and showed a noticeable stability over 30 days following irradiation. It was found that Homotaurine possesses good dosimetric properties using EPR spectroscopy in high doses and is characterized by its simple spectrum.

  12. EPR/Homotaurine: A possible dosimetry system for high doses

    Science.gov (United States)

    Maghraby, A.; Salama, E.; Mansour, A.

    2011-12-01

    An EPR investigation of radiation induced radicals in Homotaurine revealed that there are two types of radicals produced after exposure to gamma radiation (60Co). EPR spectra were recorded and analyzed; also the microwave power saturation curves for both radicals were studied. The effect of change in modulation amplitude on peak-to-peak signal height and line width was investigated; this is in addition to the evaluation of energy dependence parameters compared to soft tissue and alanine dosimeters. Response of Homotaurine to different radiation doses (0.5 kGy-50 kGy) was studied and found to follow a linear relationship. Radiation induced radicals in Homotaurine persisted and showed a noticeable stability over 30 days following irradiation. It was found that Homotaurine possesses good dosimetric properties using EPR spectroscopy in high doses and is characterized by its simple spectrum.

  13. High doses of vitamin A impair iron absorption

    Directory of Open Access Journals (Sweden)

    Gabriel FR

    2012-10-01

    Full Text Available Fabíola Rainato Gabriel, Vivian MM Suen, Julio Sergio Marchini, José Eduardo Dutra de OliveiraDivision of Clinical Nutrition, Department of Internal Medicine, Ribeirão Preto School of Medicine, São Paulo University, São Paulo, BrazilObjective: The present study aimed to determine the influence of vitamin A on iron absorption when vitamin A and iron are administered together orally compared with the administration of iron alone.Methods: This was a randomized double-blind clinical trial conducted on healthy men with normal red blood cell indices. Five experiments were performed, with iron (10 mg; iron (10 mg plus vitamin A (450, 900 and 1800 µg, and placebo. After an 8-hour fast, basal (T0 blood samples were collected: basal (T0, 2 hours (T1, and 4 hours (T2 after the ingestion of the compounds to be studied. Iron was determined by inductively coupled plasma mass spectrometry. Serum ferritin was determined by an immunometric method, ie, by chemoluminescent enzyme immunoassay. Plasma retinol was measured by high-pressure liquid chromatography. Serum curves and the sum of the area under the curve adjusted to the mixed effects linear model were determined (P < 0.05.Results: Vitamin A at the doses of 450 and 900 µg had a stimulating effect, which, however, did not differ significantly from that of experiment 1 in which iron was used alone. At the dose of 1800 µg, vitamin A had a negative effect on iron absorption.Conclusion: High doses of vitamin A may cause lower serum iron levels, whereas a low dose favors iron absorption.Keywords: iron absorption, serum iron, vitamin A, oral iron, oral supplement

  14. Study of teflon pads as high doses dosemeters; Estudo de pastilhas de teflon como dosimetros de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines; Caldas, Linda V.E., E-mail: miteixeira@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-11-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ({sup 60}Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry.

  15. High-dose vs low-dose proton pump inhibitors for upper gastrointestinal bleeding:A meta-analysis

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM:To evaluate the efficacy of high-dose proton pump inhibitors(PPIs)vs low-dose PPIs for patients with upper gastrointestinal bleeding.METHODS:PubMed,Embase,the Cochrane Library,and Web of Science were searched to identify relevant randomized controlled trials(RCTs).Eligible trials were RCTs that compared high-dose PPI with low-dose PPI following endoscopic hemostasis.The primary endpoint was rebleeding;secondary endpoints were patient numbers that needed surgery,and mortality.The meta-analysis was perfor...

  16. Identification of dose-reduction techniques for BWR and PWR repetitive high-dose jobs

    Energy Technology Data Exchange (ETDEWEB)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    As a result of concern about the apparent increase in collective radiation dose to workers at nuclear power plants, this project will provide information to industry in preplanning for radiation protection during maintenance operations. This study identifies Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) repetitive jobs, and respective collective dose trends and dose reduction techniques. 3 references, 2 tables. (ACR)

  17. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  18. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Kinhikar, Rajesh A [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Sharma, Pramod K [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Tambe, Chandrashekhar M [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Mahantshetty, Umesh M [Department of Radiation Oncology, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Sarin, Rajiv [Advanced Centre for Training Research and Education in Cancer, Kharghar, Navi Mumbai (India); Deshpande, Deepak D [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Shrivastava, Shyam K [Department of Radiation Oncology, Tata Memorial Hospital, Parel, Mumbai 400 012 (India)

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  19. High doses of recombinant erythropoietin stimulate platelet production in mice

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.P.; Cottrell, M.B.; Clift, R.E.; Cullen, W.C.; Lin, F.K.

    1987-07-01

    Previously, recombinant erythropoietin (rEpo) was shown to increase the number and size of megakaryocytic colonies in vitro, and in vivo it elevates the number of megakaryocytes in mouse spleens. To test the hypothesis that rEpo would stimulate platelet production in mice, both normal mice and mice in rebound-thrombocytosis were injected with rEpo and the %35S incorporation into platelets was measured. A thrombocytopoiesis-stimulating factor (TSF or thrombopoietin) was used as a positive control. rEpo increased isotopic incorporation into platelets of both normal mice and mice in rebound-thrombocytosis, as did TSF, but required large doses (15 U rEpo/mouse). In other mice, hematocrits, platelet counts, platelet sizes, and 24-hr %35S incorporation into platelets were measured 2 days after injection of two equally divided doses of either rEpo or TSF. Significant increases in both platelet sizes and %35S incorporation into platelets were found after injections of 15 U rEpo/mouse or 2.3 U TSF/mouse. These data indicate that rEpo, at high doses, will stimulate platelet production in mice, and may suggest molecular similarities between rEpo and TSF and their ability to compete for common receptor sites on megakaryocytes and their progenitor cells.

  20. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ken; Mitomo, Masanori [Osaka National Hospital (Japan); Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji [Osaka Prefectural Center for Adult Diseases (Japan); Yoshida, Mineo [Sanda City Hospital, Hyogo (Japan)

    2002-12-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients

  1. SU-E-T-165: Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Buzurovic, I; Hansen, J; Bhagwat, M; O’Farrell, D; Damato, A; Friesen, S; Devlin, P; Cormack, R [Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: To characterize dose distributions in high-dose-rate(HDR) surface brachytherapy using an Ir-125 source for different geometries, field sizes and topology of the clinical targets(CT). To investigate the depth doses at the central axis(CAX), edges of the treatment fields(E), and lateral dose distributions(L) present when using flap applicators in skin cancer treatments. Methods: When malignancies diagnosed on the skin are treated, various geometries of the CT require proper adaptation of the flap or custom-made applicators to the treatment site. Consequently, the dose at the depth on CAX and field edges changes with variation of the curvatures and size of the applicators. To assess the dose distributions, we created a total of 10 treatment plans(TP) for 10×10 and 20×20 field sizes(FS) with a step size of 1cm. The geometry of the applicators was: planar(PA), curved to 30(CA30) and 60(CA60) degrees with respect to the CAX, half-cylinder(HC), and cylindrical shape(CS). One additional TP was created in which the applicators were positioned to form a dome shape(DS) with a diameter of 16cm. This TP was used to emulate treatment of the average sized scalp. All TPs were optimized to deliver a prescription dose at 8mm equidistantly from the planes containing the dwell positions. This optimization is equivalent to the clinical arrangement since the SSD for the flap applicators is 5mm and the prescription depth is 3mm in the majority of clinical cases. Results: The depths (in mm) of the isodose lines were: FS(10×10):PA[90%(9.1CAX,8.0E,7.6L),50%(28.3CAX,20E,17.3L), 25%(51.1CAX,40E,27L)],CA30[90%(10.3CAX,8.2E,7.9L),50%(32.1CAX, 16.2E,15.8L),25%(61.3CAX,36.7E,31.8L)],CA60[90%(12.2CAX,6.1E,6.3L ),50%(47CAX,14E,16.6L),25%(70.8CAX,31.9E,35.4L)],HC[90%(11.1CA X,6.3E,7.3L),50%(38.3CAX,14.6E,16.1L),25%(66.2CAX,33.8E,34.2L)];FS (20×20):PA[90%(11.1CAX,9.0E,7.0L),50%(34.4CAX,21.9E,15.3L),25%(7 0.4CAX,50.9E,34.8L)],CA30[90%(10.9CAX,7.5E,7.1L),50%(38.8CAX,16. 7E,15.4L),25

  2. Labour induction with an intermediate-dose oxytocin regimen has advantages over a high-dose regimen.

    Science.gov (United States)

    Manjula, B G; Bagga, R; Kalra, J; Dutta, S

    2015-05-01

    A total of 200 women planned for labour induction were randomised to receive high-dose oxytocin (6 mU/min with similar increments every 45 min) or intermediate-dose oxytocin (3 mU/min with similar increments every 45 min). Oxytocin solution was prepared with 30 units in 500 ml saline with which the infusion rate in ml/h is numerically equal to oxytocin in mU/min. We observed that the caesarean rate (18% vs 6%, p = 0.009), contraction abnormalities (35% vs 14%, p = 0.0005) and neonatal bilirubin levels (7.99 ± 2.70 vs 6.80 ± 2.65, p = 0.002) were higher with high-dose than with intermediate-dose. The induction-delivery interval (IDI) was similar (10 h 13 min with high-dose and 11 h 5 min with intermediate-dose; p = 0.237, NS). Nulliparous women benefited more with intermediate-dose as the caesarean rate was higher with high-dose (24.6% vs 7.9%, p = 0.011). Although the caesarean rate was higher in multiparous women with high-dose oxytocin, it was statistically not significant (5.7% vs 2.7%; p = 0.609). Oxytocin regimens for labour induction are usually high-dose (4-6 mU/min) or low-dose (1-1.5 mU/min). The former is associated with more contraction abnormalities and the latter with prolonged IDI; both result in an increased caesarean rate. In order to offset these disadvantages, an intermediate- dose regimen was selected. The increment interval of 45 min was selected in accordance with the pharmacokinetics of oxytocin. We observed a lower caesarean rate when compared with the high-dose regimen, without any increase in the IDI. Hence, we propose that the intermediate-dose oxytocin regimen should be preferred to the high-dose regimen for labour induction.

  3. Rectal dose-volume constraints in high-dose radiotherapy of localized prostate cancer.

    Science.gov (United States)

    Fiorino, Claudio; Sanguineti, Giuseppe; Cozzarini, Cesare; Fellin, Gianni; Foppiano, Franca; Menegotti, Loris; Piazzolla, Anna; Vavassori, Vittorio; Valdagni, Riccardo

    2003-11-15

    To investigate the relationship between rectal bleeding and dosimetric-clinical parameters in patients receiving three-dimensional conformal radiotherapy (3D-CRT) for localized prostate cancer. In a retrospective national study (AIROPROS01-01, AIRO: Associazione Italiana Radioterapia Oncologica), planning/clinical data for 245 consecutive patients with stage T1-4N0-x prostate carcinoma who underwent 3D-CRT to 70-78 Gy (ICRU point) were pooled from four Italian institutions. The correlation between late rectal bleeding and rectal dose-volume data (the percentage of rectum receiving more than 50, 55, 60, 65, 70, and 75 Gy [V(50-70)]) and other dosimetric and clinical parameters were investigated in univariate (log-rank) and multivariate (Cox regression model) analyses. Median follow-up was 2 years. Twenty-three patients were scored as late bleeders according to a modified RTOG definition (Grade 2: 16; Grade 3: 7); the actuarial 2-year rate was 9.2%. Excepting V75, all median and third quartile V(50-70) values were found to be significantly correlated with late bleeding at univariate analysis. The smallest p value was seen for V(50) below/above the third quartile value (66%). The V70 (cut-off value: 30%) was found to be also predictive for late bleeding. In the high-dose subgroup (74-78 Gy), Grade 3 bleeding was highly correlated with this constraint. The predictive value of both V(50) and V(70) was confirmed by multivariate analyses. The present article provides evidence for correlation between rectal DVH parameters and late rectal bleeding in patients treated with curative intent with 3D-CRT. To keep the rate of moderate/severe rectal bleeding below 5-10%, it seems advisable to limit V(50) to 60-65%, V(60) to 45-50%, and V70 to 25-30%.

  4. Cation disorder in high-dose, neutron-irradiated spinel

    Energy Technology Data Exchange (ETDEWEB)

    Sickafus, K.E.; Larson, A.C.; Yu, N. [Los Alamos National Lab., CA (United States)] [and others

    1995-04-01

    The objective of this effort is to determine whether MgAl{sub 2}O{sub 4} spinel is a suitable ceramic for fusion applications. The crystal structures of MgAl{sub 2}O{sub 4} spinel single crystals irradiated to high neutron fluences [>5{times}10{sup 26} n/m{sup 2} (E{sub n}>0.1 MeV)] were examined by neutron diffraction. Crystal structure refinement of the highese dose sample indicated that the average scattering strength of the tetrahedral crystal sites decreased by {approx}20% while increasing by {approx}8% on octahedral sites.

  5. Krait bite requiring high dose antivenom: a case report.

    Science.gov (United States)

    Sharma, Sanjib Kumar; Koirala, Shekhar; Dahal, Gaheraj

    2002-03-01

    Anti snake venom (ASV) is the most specific therapy available for treatment of snakebite envenomation. The ASV available in Nepal are polyvalent ASV produced in India and are effective against envenomation by cobra and krait, the two most common species found in Eastern Nepal. Neurotoxic signs respond slowly and unconvincingly and continuous absorption of venom may cause recurrent neurotoxicity. Therefore, close observation and continuous administration of ASV is essential to save the victim. We report a case of neurotoxic envenomation due to bite by common krait (Bangarus caeruleus). The victim required very high dose of polyvalent ASV for reversal of neurological manifestations.

  6. Physical characteristics of the Selectron high dose rate intracavitary afterloader

    Energy Technology Data Exchange (ETDEWEB)

    Chenery, S.G.A.; Pla, M.; Podgorsak, E.B. (Royal Victoria Hospital, Montreal, Quebec (Canada); McGill Univ., Montreal, Quebec (Canada))

    1985-08-01

    The physics measurements on a Selectron high dose-rate afterloading cobalt-60 unit are reported. The installation was found to be acceptable from the standpoint of radiation safety and cost effectiveness; hospital bed space was saved as treatment could be on an outpatient basis. A source calibration 4% higher than the value stated by the manufacturer was obtained. Measurement of the ratio of exposure rate in water to that in air confirmed the calibration and the applicability of correction factors for routine clinical dosimetry recommended in the literature.

  7. High dose intravenous immunoglobulin may be complicated by myocardial infarction

    Directory of Open Access Journals (Sweden)

    Kolar Vishwanath Vinod

    2014-01-01

    Full Text Available Intravenous immunoglobulin [IVIg] is useful for treating several clinical conditions and is largely considered safe, without major adverse events. Here we report a case of acute ST elevation myocardial infarction associated with high dose IVIg administration in a previously healthy 69-year-old male patient of Guillain Barre syndrome. The case is being reported to emphasize the need for treating physicians to be aware of thrombotic complications associated with IVIg. The thrombotic complications associated with IVIg are reviewed in brief , and the measures to reduce them are discussed.

  8. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  9. High-dose vs low-dose proton pump inhibitors for upper gastrointestinal bleeding: a meta-analysis.

    Science.gov (United States)

    Wu, Liu-Cheng; Cao, Yun-Fei; Huang, Jia-Hao; Liao, Cun; Gao, Feng

    2010-05-28

    To evaluate the efficacy of high-dose proton pump inhibitors (PPIs) vs low-dose PPIs for patients with upper gastrointestinal bleeding. PubMed, Embase, the Cochrane Library, and Web of Science were searched to identify relevant randomized controlled trials (RCTs). Eligible trials were RCTs that compared high-dose PPI with low-dose PPI following endoscopic hemostasis. The primary endpoint was rebleeding; secondary endpoints were patient numbers that needed surgery, and mortality. The meta-analysis was performed with a fixed effects model or random effects model. Nine eligible RCTs including 1342 patients were retrieved. The results showed that high-dose intravenous PPI was not superior to low-dose intravenous PPI in reducing rebleeding [odds ratio (OR) = 1.091, 95% confidential interval (CI): 0.777-1.532], need for surgery (OR = 1.522, 95% CI: 0.643-3.605) and mortality (OR = 1.022, 95% CI: 0.476-2.196). Subgroup analysis according to different region revealed no difference in rebleeding rate between Asian patients (OR = 0.831, 95% CI, 0.467-1.480) and European patients (OR = 1.263, 95% CI: 0.827-1.929). Low-dose intravenous PPI can achieve the same efficacy as high-dose PPI following endoscopic hemostasis.

  10. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  11. Impact of high dose vitamin C on platelet function

    Science.gov (United States)

    Mohammed, Bassem M; Sanford, Kimberly W; Fisher, Bernard J; Martin, Erika J; Contaifer Jr, Daniel; Warncke, Urszula Osinska; Wijesinghe, Dayanjan S; Chalfant, Charles E; Brophy, Donald F; Fowler III, Alpha A; Natarajan, Ramesh

    2017-01-01

    AIM To examine the effect of high doses of vitamin C (VitC) on ex vivo human platelets (PLTs). METHODS Platelet concentrates collected for therapeutic or prophylactic transfusions were exposed to: (1) normal saline (control); (2) 0.3 mmol/L VitC (Lo VitC); or (3) 3 mmol/L VitC (Hi VitC, final concentrations) and stored appropriately. The VitC additive was preservative-free buffered ascorbic acid in water, pH 5.5 to 7.0, adjusted with sodium bicarbonate and sodium hydroxide. The doses of VitC used here correspond to plasma VitC levels reported in recently completed clinical trials. Prior to supplementation, a baseline sample was collected for analysis. PLTs were sampled again on days 2, 5 and 8 and assayed for changes in PLT function by: Thromboelastography (TEG), for changes in viscoelastic properties; aggregometry, for PLT aggregation and adenosine triphosphate (ATP) secretion in response to collagen or adenosine diphosphate (ADP); and flow cytometry, for changes in expression of CD-31, CD41a, CD62p and CD63. In addition, PLT intracellular VitC content was measured using a fluorimetric assay for ascorbic acid and PLT poor plasma was used for plasma coagulation tests [prothrombin time (PT), partial thrombplastin time (PTT), functional fibrinogen] and Lipidomics analysis (UPLC ESI-MS/MS). RESULTS VitC supplementation significantly increased PLTs intracellular ascorbic acid levels from 1.2 mmol/L at baseline to 3.2 mmol/L (Lo VitC) and 15.7 mmol/L (Hi VitC, P 8 d exposure period (P > 0.05). PLT function assayed by TEG, aggregometry and flow cytometry was not significantly altered by Lo or Hi VitC for up to 5 d. However, PLTs exposed to 3 mmol/L VitC for 8 d demonstrated significantly increased R and K times by TEG and a decrease in the α-angle (P 0.05). Collagen and ADP-induced ATP secretion was also not different between the three groups (P > 0.05). Finally, VitC at the higher dose (3 mmol/L) also induced the release of several eicosanoids including thromboxane B2

  12. Shelf-stable food through high dose irradiation

    Science.gov (United States)

    Plaček, V.; Svobodová, V.; Bartoníček, B.; Rosmus, J.; Čamra, M.

    2004-09-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75°C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30°C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Řež 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO x-containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested.

  13. Shelf-stable food through high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Placek, V. E-mail: pla@ujv.cz; Svobodova, V.; Bartonicek, B.; Rosmus, J.; Camra, M

    2004-10-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75 deg. C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30 deg. C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Rez 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO{sub x}-containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested.

  14. High-dose processing and application to Korean space foods

    Science.gov (United States)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il; Kim, Jae-Hun; Byun, Myung-Woo; Kang, Sang-Wook; Choi, Gi-Hyuk; Lee, Ju-Woon

    2009-07-01

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods ( Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 °C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  15. Characterization of a silicate glass as a high dose dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Farah, K., E-mail: k.farah@cnstn.rnrt.t [Laboratoire de Radiotraitement. Centre National des Sciences et Technologie Nucleaires, 2020 Sidi-Thabet (Tunisia); Mejri, A.; Hosni, F. [Laboratoire de Radiotraitement. Centre National des Sciences et Technologie Nucleaires, 2020 Sidi-Thabet (Tunisia); Ben Ouada, H. [Laboratoire de Physique et Chimie des Interfaces, Faculte des Sciences de Monastir, 5000 Monastir (Tunisia); Fuochi, P.G.; Lavalle, M. [ISOF-CNR, Via P. Gobetti 101, 40129 Bologna (Italy); Kovacs, A. [Institute of Isotopes, HAS, P.O. Box 77, H-1525 Budapest (Hungary)

    2010-02-21

    Commercial silicate glass has been investigated as a possible high dose dosimeter using an UV-vis spectrophotometer. Glass samples were irradiated by {sup 60}Co gamma rays and the results compared with those obtained with 3.4 and 8.4 MeV electron beams. The irradiated samples showed rapid fading at room temperature immediately after irradiation. In order to improve the stability of absorbance, glass samples were submitted to post-irradiation thermal treatments (150 deg. C for 20 min). The influences of the dose, type and energy of the ionizing radiation on the fading characteristics and on the response of the irradiated and thermally treated glasses were studied. Dependence of the glass response on the temperature during gamma irradiation in the range -3 to 80 deg. C is reported. The reproducibility to reuse glass dosimeter by thermal bleaching the radiation induced colour centres at 300 deg. C for 30 min was also investigated. Calibration curves in the range 0.1-17 kGy were obtained by using in-plant calibration techniques against transfer standard alanine dosimeters in the Tunisian semi-industrial gamma irradiation facility.

  16. High-dose processing and application to Korean space foods

    Energy Technology Data Exchange (ETDEWEB)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kim, Jae-Hun [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Byun, Myung-Woo [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kang, Sang-Wook; Choi, Gi-Hyuk [Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Lee, Ju-Woon [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of)], E-mail: sjwlee@kaeri.re.kr

    2009-07-15

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods (Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 {sup o}C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  17. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  18. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  19. Comparison of low-dose and high-dose cosyntropin stimulation testing in children.

    Science.gov (United States)

    Cemeroglu, Ayse Pinar; Kleis, Lora; Postellon, Daniel C; Wood, Michael A

    2011-04-01

      There is no consensus among pediatric endocrinologists in using low-dose (LD) versus high-dose (HD) cosyntropin to test for secondary/tertiary adrenal insufficiency. This paper compares LD and HD cosyntropin stimulation testing in children for evaluation of hypothalamic-pituitary-adrenal axis (HPAA) and suggests a new peak cortisol cut-off value for LD stimulation testing to avoid false positivity.   Data of 36 children receiving LD (1 µg) and HD (249 µg) cosyntropin consecutively during growth hormone (GH) stimulation testing were analyzed in two groups. Group A were patients who passed GH stimulation testing and were not on oral, inhaled or intranasal steroids (intact hypothalamic-pituitary axis, n= 19). Group B were patients who failed GH stimulation testing and/or were on oral, inhaled or intranasal steroids (impaired hypothalamic-pituitary axis, n= 17).   In group A, the mean peak cortisol response in LD cosyntropin was 18.5 ± 2.4 µg/dL and that for the HD cosyntropin was 24.8 ± 3.1 µg/dL (r: 0.76, P≤ 0.05). In group B, the mean peak cortisol response in LD cosyntropin was 15.7 ± 6.1 µg/dL and that for HD cosyntropin was 21.7 ± 7.9 µg/dL (r: 0.98, P≤ 0.05). When a standard cut-off of 18 µg/dL was used, 37% of the patients with intact HPAA failed LD cosyntropin testing, but a cut-off of 14 µg/dL eliminated false positive results.   LD cosyntropin stimulation testing results should be interpreted cautiously when used alone to prevent unnecessary long-term treatment. Using a lower cut-off for LD (≥14 µg/dL) seems to avoid false positive results and still detects most cases of impaired HPAA. © 2011 The Authors.Pediatrics International © 2011 Japan Pediatric Society.

  20. High-dose thiamine improves the symptoms of fibromyalgia.

    Science.gov (United States)

    Costantini, Antonio; Pala, Maria Immacolata; Tundo, Silvia; Matteucci, Pietro

    2013-05-20

    Living with fibromyalgia means living with chronic pain, fatigue, sleep disorders and other associated key symptoms. To date, pharmacotherapy generally produces modest benefits. Some observations indicate that the large majority of symptoms of fibromyalgia could be the clinical manifestation of a mild thiamine deficiency due to a dysfunction of the active transport of thiamine from the blood to the mitochondria or to enzymatic abnormalities. Between June and July 2011, we recruited three female patients affected by fibromyalgia. We proceeded with the study of the patients' history, a physical examination, an evaluation of chronic widespread pain using the Visual Numeric Scale and an evaluation of the fatigue using the Fatigue Severity Scale were also performed. The levels of thiamine and thiamine pyrophosphate in the blood were determined. After the therapy with high doses of thiamine, in the patients, there was an appreciable improvement of the symptoms.

  1. High-dose thiamine improves the symptoms of Friedreich's ataxia.

    Science.gov (United States)

    Costantini, Antonio; Giorgi, Rafaela; D'Agostino, Sonia; Pala, Maria Immacolata

    2013-05-22

    Friedreich's ataxia (FRDA) is an autosomal recessive inherited disorder characterised by progressive gait and limb ataxia, dysarthria, areflexia, loss of position sense and a progressive motor weakness of central origin. Some observations indicate that all symptoms of FRDA ataxia could be the manifestation of a thiamine deficiency because of enzymatic abnormalities. Two patients with FRDA were under rehabilitative treatment from February 2012 to February 2013. The scale for assessment and rating of ataxia was performed. The patient began an intramuscular therapy with 100 mg of thiamine every 3-5 days. Injection of high-dose thiamine was effective in reversing the motor failure. From this clinical observation, it is reasonable to infer that a thiamine deficiency due to enzymatic abnormalities could cause a selective neuronal damage in the centres that are typically affected by this disease.

  2. Pharmacokinetics of high-dose intravenous melatonin in humans

    DEFF Research Database (Denmark)

    Andersen, Lars P H; Werner, Mads U; Rosenkilde, Mette Marie

    2016-01-01

    This crossover study investigated the pharmacokinetics and adverse effects of high-dose intravenous melatonin. Volunteers participated in 3 identical study sessions, receiving an intravenous bolus of 10 mg melatonin, 100 mg melatonin, and placebo. Blood samples were collected at baseline and 0, 60......, 120, 180, 240, 300, 360, and 420 minutes after the bolus. Quantitative determination of plasma melatonin concentrations was performed using a radioimmunoassay technique. Pharmacokinetic parameters were estimated by a compartmental pharmacokinetic analysis. Adverse effects included assessments...... of sedation and registration of other symptoms. Sedation, evaluated as simple reaction times, was measured at baseline and 120, 180, 300, and 420 minutes after the bolus. Twelve male volunteers completed the study. Median (IQR) Cmax after the bolus injections of 10 mg and 100 mg of melatonin were 221...

  3. "Time sequential high dose of Cytarabine in acute myelocytic leukemia "

    Directory of Open Access Journals (Sweden)

    Ghavamzadeh A

    2003-05-01

    Full Text Available Given preliminary evidence of timed, sequential chemotherapy of high dose cytosine arabinoside the current study was initiated to assess the side effects and efficacy of this regimen in patients with newly acute myelocytic leukemia (AML. Nineteen adults who referred to Hematology-Oncology and Bone Marrow Transplantation (BMT research center of Tehran University of Medical Sciences were enrolled in a trial from Aug 1999 to Nov 2000. All patients had a Karnofski classification above 60%. At this time induction therapy consisted of daunorubicin or idarubicin given at a dose of 60 mg/m² and 12 mg/m² IV respectively on days 1-3, and cytarabine (Ara-C 100 mg/m² intravenously by continuous infusion on days 1-7, followed by Ara-C 1000 mg/m² given on day 8-10 every 12 hours by IV infusion. Consolidation therapy started after 35th day. Of 19 fully evaluable patients, 10 patients achieved a complete remission, whereas 36.6% patients succumbed to death due to regeneration failure. The clinical data show that the overall survival rate from diagnosis 55.5% (95% CI, 30.8-78.5 at 6 months for the entire cohort of the patients. Disease free survival is also 50% (95% CI, 26-74. Mean duration of death due to treatment was 20 days (range 17-29 after beginning the regimen. Presenting WBC counts, French-American-British (FAB classification, sex and age were not useful prognostic variables. Fever, diarrhea, nausea and vomiting and GI hemorrhage were seen in 19, 6, 4, 7 patients respectively. It seems the 3+7+3 regimen is a promising approach for the AML patients regarding to high complete remission rate, but more supportive care should be considered. Furthermore any, benefit in long-term outcome can’t be determined regardless to the choice of post remission therapy (e.g., GCSF, appropriate antibiotics and etc.

  4. High-Dose Vitamin D Failed to Curb Heart Disease in Study

    Science.gov (United States)

    ... medlineplus.gov/news/fullstory_164472.html High-Dose Vitamin D Failed to Curb Heart Disease in Study ... 5, 2017 (HealthDay News) -- Taking high doses of vitamin D once a month won't lower your ...

  5. Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts After Exposure to Very Low Dose of High Let Radiation

    Science.gov (United States)

    Hada, M.; George, K.; Chappell, L.; Cucinotta, F. A.

    2011-01-01

    The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivor with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (0.01 - 0.20 Gy) of 170 MeV/u Si-28 ions or 600 MeV/u Fe-56 ions, including doses where on average less than one direct ion traversal per cell nucleus occurs. Chromosomes were analyzed using the whole-chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). The responses for doses above 0.1 Gy (more than one ion traverses a cell) showed linear dose responses. However, for doses less than 0.1 Gy, both Si-28 ions and Fe-56 ions showed a dose independent response above background chromosome aberrations frequencies. Possible explanations for our results are non-targeted effects due to aberrant cell signaling [1], or delta-ray dose fluctuations [2] where a fraction of cells receive significant delta-ray doses due to the contributions of multiple ion tracks that do not directly traverse cell nuclei where chromosome aberrations are scored.

  6. Analysis of renal impairment in MM-003, a phase III study of pomalidomide + low - dose dexamethasone versus high - dose dexamethasone in refractory or relapsed and refractory multiple myeloma

    OpenAIRE

    Weisel, Katja C.; Dimopoulos, Meletios A.; Moreau, Philippe; Lacy, Martha Q.; Song, Kevin W.; Delforge, Michel; Karlin, Lionel; Goldschmidt, Hartmut; Banos, Anne; Oriol, Albert; Alegre, Adrian; Chen, Christine; Cavo, Michele; Garderet, Laurent; Ivanova, Valentina

    2016-01-01

    Pomalidomide + low-dose dexamethasone is effective and well tolerated for refractory or relapsed and refractory multiple myeloma after bortezomib and lenalidomide failure. The phase III trial MM-003 compared pomalidomide + low-dose dexamethasone with high-dose dexamethasone. This subanalysis grouped patients by baseline creatinine clearance ≥ 30 − < 60 mL/min (n=93, pomalidomide + low-dose dexamethasone; n=56, high-dose dexamethasone) or ≥ 60 mL/min (n=205, pomalidomide + low-dose dexamethaso...

  7. Antagonism by idazoxan at low dose but not high dose, of the natriuretic action of moxonidine.

    Science.gov (United States)

    Allan, D. R.; Penner, S. B.; Smyth, D. D.

    1996-01-01

    1. Recent studies concerning the imidazoline receptor have utilized idazoxan as a specific imidazoline receptor antagonist. The aim of the present study was to describe the in vivo effects of various doses of idazoxan on renal function, in the presence and absence of moxonidine, an I1 imidazoline receptor agonist. 2. In anaesthetized, unilaterally nephrectomized (7 to 10 days) Sprague Dawley rats, an intrarenal infusion of moxonidine (3 nmol kg-1 min-1) increased urine flow rate, sodium excretion and osmolar clearance without altering free water clearance. Pretreatment with intravenous idazoxan at 0.1 and 0.3 mg kg-1 produced a dose-related decrease in the renal actions of moxonidine. However, a higher dose of idazoxan (1 mg kg-1) was not as effective as the 0.3 mg kg-1 dose in blocking the effects of moxonidine. 3. In a separate series of experiments, the direct renal actions of idazoxan alone were investigated. Idazoxan at 0.3 mg kg-1 failed to alter urine flow rate and sodium excretion. However, idazoxan at 1 mg kg-1 produced a significant increase in urine flow rate and sodium excretion in association with an increase in osmolar clearance. 4. These results do not prove but are consistent with low doses of idazoxan antagonizing the sites stimulated by moxonidine (renal imidazoline receptors). However, at higher doses, idazoxan may function as a partial agonist and/or interact with other receptors to increase urine flow rate, independent of imidazoline receptor blockade. These studies underscore the importance of the dose of idazoxan administered when this antagonist is used as a tool to investigate imidazoline receptors. PMID:8825339

  8. Comparison of commercial thermoluminescent readers regarding high-dose high-temperature measurements

    CERN Document Server

    Bilski, P; Obryk, B; Hodyr, K

    2014-01-01

    Three different thermoluminescent measuring systems have been compared with respect to the differences in temperature profiles, spectral sensitivities, as well as linearity of dose response characteristics. The comparison was performed using the Harshaw 3500, Riso DA-20 and RA94 TLD readers. The instruments were tested for the readouts of highly irradiated LiF:Mg,Cu,P (MCP) TL detectors, which require readout up to 550 C, in case of doses exceeding 1 kGy. It was found that the Harshaw 3500 can be used, without any additional light attenuation, for the measurements of MCP detectors exposed to doses up to about 5 Gy. For the other two readers the upper dose limit is about 5 times lower. It was also found that the Harshaw 3500 shows the best thermal stability considering the peak maximum position. For the ultra-high doses the differences in the spectral characteristics of the applied optical filters and photomultipliers, in conjunction with an evolution of the MCP TL emission spectrum with increasing dose, signi...

  9. ``In vivo'' Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal

    Science.gov (United States)

    Mejía, C. A. Reynoso; Burgos, A. E. Buenfil; Trejo, C. Ruiz; García, A. Mota; Durán, E. Trejo; Ponce, M. Rodríguez; de Buen, I. Gamboa

    2010-12-01

    The aim of this thesis project is to compare doses calculated from the treatment planning system using computed tomography images, with those measured "in vivo" by using thermoluminescent dosimeters placed at different regions of the rectum and bladder of a patient during high-dose-rate intracavitary brachytherapy treatment of uterine cervical carcinoma. The experimental dosimeters characterisation and calibration have concluded and the protocol to carry out the "in vivo" measurements has been established. In this work, the calibration curves of two types of thermoluminescent dosimeters (rods and chips) are presented, and the proposed protocol to measure the "in vivo" dose is fully described.

  10. Very high dose phenobarbital for refractory status epilepticus.

    Science.gov (United States)

    Tiamkao, Somsak; Mayurasakorn, Nattakarn; Suko, Panit; Jitpimolmard, Suthipun; Arunpongpaisal, Suwanna; Phuttharak, Warinthorn; Auevitchayapat, Narong; Vannaprasaht, Suda; Tiamkao, Siriporn; Phunikhom, Kutcharin; Chaiyakum, Aporanee; Saengsuwan, Jiamjit

    2007-12-01

    Refractory status epilepticus (RSE), defined as status epilepticus that fails to respond to first, second and third-line therapy. The RSE is associated with high morbidity and mortality. Treatment guidelines of RSE give a spectrum of options, such as, continuous intravenous (i.v.) midazolam (MDL), or continuous i.v. propofol (PRO) as alternatives to phenobarbital (PB) or continuous i.v. pentobarbital (PTB). To study the efficacy of very-high-dose phenobarbital (VHDPB) for treatment RSE. Retrospective study The authors collected and analyzed data from adult patients who were diagnosed with RSE. The authors present 10 patients with RSE who were treated with VHDPB. All of them were generalized convulsive status epilepticus (GCSE). Ages ranged from 16-86 years old (mean.: 43 years). PB dosage ranged 40-140 mg/kg/day (mean: 70 mg/kg/day). The duration of status epilepticus (SE) varied widely, ranged 1-44 days (mean: 7 days). PB level ranged 35.29-218.34 ug/mL (mean 88.1 ug/mL). RSE was controlled by VHDPB 70%, 30% were not controlled. VHDPB were considered as alternative treatment for RSE.

  11. High-dose pyridoxine as an 'anti-stress' strategy.

    Science.gov (United States)

    McCarty, M F

    2000-05-01

    Pyridoxine nutritional status has a significant and selective modulatory impact on central production of both serotonin and GABA - neurotransmitters which control depression, pain perception, and anxiety - owing to the fact that the decarboxylases which produce these neurotransmitters have a relatively low affinity for pyridoxal phosphate (PLP). Pyridoxine deficiency leads to increased sympathetic outflow and hypertension in rodents, possibly reflecting decreased central production of these neurotransmitters; conversely, supplemental pyridoxine lowers blood pressure in many animal models of hypertension, and there is preliminary evidence for antihypertensive activity in humans as well. Additionally, physiological levels of PLP interact with glucocorticoid receptors to down-regulate their activity. Thus, high-dose pyridoxine, by amplifying tissue levels of PLP, may be expected to have a favorable impact on certain dysphoric mental states, while diminishing sympathetic output and acting peripherally to blunt the physiological impact of corticosteroids. In light of growing evidence that chronic dysphoria, particularly when accompanied by hopelessness or cynicism, has a major negative impact on morbidity and mortality from a wide range of disorders, high intakes of pyridoxine may have the potential to improve prognosis in many individuals. With respect to cardiovascular health, reduction of homocysteine levels should contribute to this benefit. These predictions are consistent with recent epidemiology correlating plasma PLP levels with risk for vascular events and overall survival.

  12. A comparison of high-dose and low-dose tranexamic acid antifibrinolytic protocols for primary coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Stephen M McHugh

    2016-01-01

    Full Text Available Background and Aims: Tranexamic acid (TA is used for prophylactic antifibrinolysis in coronary artery bypass surgeries to reduce bleeding. We evaluated the efficacy of two different doses of TA for prophylactic antifibrinolysis in patients undergoing primary coronary artery bypass grafting (CABG surgery in this retrospective cohort study at a tertiary care referral centre. Methods: One-hundred eighty-four patients who underwent primary CABG with cardiopulmonary bypass (CPB via sternotomy between January 2009 and June 2011 were evaluated. Pre-operative patient characteristics, intraoperative data, post-operative bleeding, transfusions, organ dysfunction and 30-day mortality were compared between high-dose TA (30 mg/kg loading dose followed by infusion of 15 mg/kg/h until the end of surgery along with 2 mg/kg priming dose in the bypass circuit and low-dose TA (15 mg/kg loading dose followed by infusion of 6 mg/kg/h until the end of surgery along with 1 mg/kg priming dose in the bypass circuit groups. Univariate comparative analysis of all categorical and continuous variables was performed between the two groups by appropriate statistical tests. Linear and logistic regression analyses were performed to control for the effect of confounding on the outcome variables. Results: Chest tube output, perioperative transfusion of blood products and incidence of re-exploration for bleeding did not differ significantly (P> 0.05 between groups. Post-operative complications and 30-day mortality were comparable between the groups. The presence of cardiogenic shock and increased pre-operative creatinine were found to be associated with increased chest tube output on the post-operative day 2 by multivariable linear regression model. Conclusions: Low-dose TA protocol is as effective as high-dose protocol for antifibrinolysis in patients undergoing primary CABG with CPB.

  13. Efficacy of a single high dose versus multiple low doses of LLLT on wounded skin fibroblasts

    Science.gov (United States)

    Hawkins, Denise H.; Abrahamse, Heidi

    2007-07-01

    Background/purpose: In vivo studies have demonstrated that phototherapy accelerates wound healing in the clinical environment; however the exact mechanism is still not completely understood. The main focus of this study was to use in vitro laboratory results to establish an effective treatment regimen that may be practical and applicable to the clinical environment. This in vitro study aimed to compare the cellular responses of wounded fibroblasts following a single exposure of 5 J/cm2 or multiple exposures of low doses (2.5 J/cm2 or 5 J/cm2) on one day of the week to a single application of a higher dose (16 J/cm2) on day 1 and day 4. Methodology: Cellular responses to Helium-Neon (632.8 nm) laser irradiation were evaluated by measuring changes in cell morphology, cell viability, cell proliferation, membrane integrity and DNA damage. Results: Wounded cells exposed to 5 J/cm2 on day 1 and day 4 showed an increase in cell viability, increase in the release of bFGF, increase in cell density, decrease in ALP enzyme activity and decrease in caspase 3/7 activity indicating a stimulatory effect. Wounded cells exposed to three doses of 5 J/cm2 on day 1 showed a decrease in cell viability and cell proliferation and an increase in LDH cytotoxicity and DNA damage indicating an inhibitory effect. Conclusion: Results indicate that cellular responses are influenced by the combination of dose administered, number of exposures and time between exposures. Single doses administered with sufficient time between exposures is more beneficial to restoring cell function than multiple doses within a short period. Although this work confirms previous reports on the cumulative effect of laser irradiation it provides essential information for the initiation of in vivo clinical studies.

  14. Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts after Exposure to Very Low Doses of High LET Radiation

    Science.gov (United States)

    Hada, M.; George, Kerry; Cucinotta, Francis A.

    2011-01-01

    The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivors with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (1-20 cGy) of 170 MeV/u Si-28- ions or 600 MeV/u Fe-56-ions. Chromosomes were analyzed using the whole chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving greater than 2 breaks in 2 or more chromosomes). The curves for doses above 10 cGy were fitted with linear or linear-quadratic functions. For Si-28- ions no dose response was observed in the 2-10 cGy dose range, suggesting a non-target effect in this range.

  15. Cutaneous dosimetry at low and high dose; Dosimetrie cutanee a faible et forte dose

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M. [CEA, iRCM, Laboratoire de Genomique et Radiobiologie de la Keratinopoiese, 2 rue G Cremieux, Evry, 91057, Evry cedex (France)

    2009-07-01

    As radiodermatitis is a complication related to the exposure to ionizing radiation after an accidental exposition or a medical examination (radiotherapy or interventional radiology), the author briefly reports an investigation of the response of the human keratinocyte to irradiation for different dose levels, and the search for exposure markers

  16. The application of high dose food irradiation in South Africa

    Science.gov (United States)

    de Bruyn, Ingrid Nine

    2000-03-01

    During the 1950s to the end of the 1970s the United States Army developed the basic methodology to produce shelf-stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive "dried cooked" taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The Biogam group at the Atomic Energy Corporation of South Africa is currently producing shelf-stable irradiated meats on a commercial basis. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 45 kGy at a temperature of between -20 and -40°C to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions and can be guaranteed for more than two years as long as the integrity of the packaging is maintained. Safari operators in remote parts of Africa, mountaineers, yachtsmen, canoeists and geological survey teams currently use shelf-stable irradiated meat products produced in South Africa.

  17. Displacement damage effects in silicon MEMS at high proton doses

    Science.gov (United States)

    Gomes, João; Shea, Herbert R.

    2011-02-01

    We report on a study of the sensitivity of silicon MEMS to proton radiation and mitigation strategies. MEMS can degrade due to ionizing radiation (electron-hole pair creation) and non-ionizing radiation (displacement damage), such as electrons, trapped and solar protons, or cosmic rays, typically found in a space environment. Over the past few years there has been several reports on the effects of ionizing radiation in silicon MEMS, with failure generally linked to trapped charge in dielectrics. However there is near complete lack of studies on displacement damage effects in silicon- MEMS: how does silicon change mechanically due to proton irradiation? We report on an investigation on the susceptibility of 50 μm thick SOI-based MEMS resonators to displacement damages due to proton beams, with energies from 1 to 60 MeV, and annealing of this damage. We measure ppm changes on the Young's modulus and Poisson ratio by means of accurately monitoring the resonant frequency of devices in vacuum using a Laser Doppler Vibrometer. We observed for the first time an increase (up to 0.05%) of the Young's modulus of single-crystal silicon electromagnetically-actuated micromirrors after exposure to low energy protons (1-4 MeV) at high absorbed doses ~ 100 Mrad (Si). This investigation will contribute to a better understanding of the susceptibility of silicon-based MEMS to displacement damages frequently encountered in a space radiation environment, and allow appropriated design margin and shielding to be implemented.

  18. Malignancies in patients treated with high doses of radium-224

    Energy Technology Data Exchange (ETDEWEB)

    Nekolla, E.A. [Federal Office for Radiation Protection (BfS), Neuherberg (Germany); Walsh, L. [Radiobiological Inst., Univ. of Munich (Germany); Schottenhammer, G.; Spiess, H. [Children' s Hospital, Univ. of Munich (Germany)

    2005-07-01

    Several thousand German patients suffering from ankylosing spondylitis, tuberculosis and some other diseases, received multiple injections of the short-lived {alpha}-emitter {sup 224}Ra. The ''Spiess study'' was initiated in the early 1950s to follow the health of 899 persons (278 female, 621 male) who were treated mainly between 1945 and 1955. Most of the high dose patients and nearly all of those treated as children or juveniles (n=217) were included in the study. In June 2003, 152 persons were still alive. The most striking observed health effect, following {sup 224}Ra injections, was a temporal wave of 56 malignant bone tumours with a maximum at about 8 years after exposure which has already been described in several publications. In 2000, a new analysis was performed because an improved dosimetry resulted in modified bone surface doses. The estimated risk coefficient, averaged over all ages at exposure, was found to be in agreement with earlier analyses. However, a statistically significant increase of bone tumour risk with decreasing age at exposure was found. The earlier results, which indicated a reversed protraction factor, were confirmed. A significant excess of non-skeletal solid malignancies has also appeared during the most recent observation decade. In 2004, significant increases of cancer rates were observed for several sites: for breast cancer (31 cases observed vs. 9.1 cases expected), soft tissue malignancies (11 vs. 1.0), thyroid carcinomas (7 vs. 0.9), liver (8 vs. 2.3), kidney (13 vs. 4.6), pancreas (8 vs. 3.9), and bladder cancer (14 vs. 7.7). The 8-fold excess relative risk of mammary cancers in those women exposed as children or juveniles is particularly striking; moreover, 2 cases of breast cancer occurred in men. In 1993, a control group of tuberculosis patients not treated with {sup 224}Ra was established to rule out potential confounding factors - such as chest fluoroscopy - which might bias the breast cancer excess

  19. Modulation of the proteolytic cascade systems by high dose corticosteroids.

    Science.gov (United States)

    Aasen, A O; Ruud, T E; Pillgram-Larsen, J; Röise, O; Stadaas, J

    1985-01-01

    The effects of high-dose corticosteroids (HDC) on activities within the proteolytic cascade systems were studied in vitro and in vivo using chromogenic peptide substrate assays. In in vitro experiments 20 mg methylprednisolone sodium succinate (Solu-Medrol) per ml plasma significantly inhibited activation of plasma prekallikrein, prothrombin and plasminogen and reduced functional plasma kallikrein inhibition, antithrombin and antiplasmin activities. The effects of HDC on activities within these proteolytic cascade systems were further evaluated in experimental acute pancreatitis in pigs. Acute pancreatitis was induced by injection of Na-taurocholate into the pancreatic duct. Seven test animals received methylprednisolone sodium succinate 30 mg per kg intravenously for 30 minutes before the induction of pancreatitis as pretreatment. Eight animals remained untreated. Trypsin (TRY), plasma prekallikrein (PKK), plasma kallikrein (KK) and functional plasma kallikrein inhibition capacity (KKI) were studied in the peritoneal exudate. Cardiac output (CO) and mean arterial pressure (MAP) were monitored regularly before and during a 6 hour observation period. During untreated pancreatitis a reduction of PKK levels of about 40% were found, paralleled by an increased KK activity and a reduction of KKI capacity. Several of the animals experienced high TRY activities. The mortality rate was 63% (5 out of 8 animals). In the pretreated groups, all animals survived the observation period. CO and MAP were significantly less reduced than the untreated group at 6 hours. HDC was also found to reduce significantly plasma kallikrein activities in the peritoneal exudate compared with untreated animals. No changes in TRY activities were found in pretreated animals. Furthermore, plasma prekallikrein and functional plasma kallikrein inhibition values in the exudate were elevated significantly in HDC treated animals compared with untreated animals.

  20. Molecular mechanisms linking high dose medroxyprogesterone with HIV-1 risk.

    Directory of Open Access Journals (Sweden)

    Susan C Irvin

    Full Text Available Epidemiological studies suggest that medroxyprogesterone acetate (MPA may increase the risk of HIV-1. The current studies were designed to identify potential underlying biological mechanisms.Human vaginal epithelial (VK2/E6E7, peripheral blood mononuclear (PBMC, and polarized endometrial (HEC-1-A cells were treated with a range of concentrations of MPA (0.015-150 μg/ml and the impact on gene expression, protein secretion, and HIV infection was evaluated.Treatment of VK2/E6E7 cells with high doses (>15 μg/ml] of MPA significantly upregulated proinflammatory cytokines, which resulted in a significant increase in HIV p24 levels secreted by latently infected U1 cells following exposure to culture supernatants harvested from MPA compared to mock-treated cells. MPA also increased syndecan expression by VK2/E6E7 cells and cells treated with 15 μg/ml of MPA bound and transferred more HIV-1 to T cells compared to mock-treated cells. Moreover, MPA treatment of epithelial cells and PBMC significantly decreased cell proliferation resulting in disruption of the epithelial barrier and decreased cytokine responses to phytohaemagglutinin, respectively.We identified several molecular mechanisms that could contribute to an association between DMPA and HIV including proinflammatory cytokine and chemokine responses that could activate the HIV promoter and recruit immune targets, increased expression of syndecans to facilitate the transfer of virus from epithelial to immune cells and decreased cell proliferation. The latter could impede the ability to maintain an effective epithelial barrier and adversely impact immune cell function. However, these responses were observed primarily following exposure to high (15-150 μg/ml MPA concentrations. Clinical correlation is needed to determine whether the prolonged MPA exposure associated with contraception activates these mechanisms in vivo.

  1. Molecular mechanisms linking high dose medroxyprogesterone with HIV-1 risk.

    Science.gov (United States)

    Irvin, Susan C; Herold, Betsy C

    2015-01-01

    Epidemiological studies suggest that medroxyprogesterone acetate (MPA) may increase the risk of HIV-1. The current studies were designed to identify potential underlying biological mechanisms. Human vaginal epithelial (VK2/E6E7), peripheral blood mononuclear (PBMC), and polarized endometrial (HEC-1-A) cells were treated with a range of concentrations of MPA (0.015-150 μg/ml) and the impact on gene expression, protein secretion, and HIV infection was evaluated. Treatment of VK2/E6E7 cells with high doses (>15 μg/ml] of MPA significantly upregulated proinflammatory cytokines, which resulted in a significant increase in HIV p24 levels secreted by latently infected U1 cells following exposure to culture supernatants harvested from MPA compared to mock-treated cells. MPA also increased syndecan expression by VK2/E6E7 cells and cells treated with 15 μg/ml of MPA bound and transferred more HIV-1 to T cells compared to mock-treated cells. Moreover, MPA treatment of epithelial cells and PBMC significantly decreased cell proliferation resulting in disruption of the epithelial barrier and decreased cytokine responses to phytohaemagglutinin, respectively. We identified several molecular mechanisms that could contribute to an association between DMPA and HIV including proinflammatory cytokine and chemokine responses that could activate the HIV promoter and recruit immune targets, increased expression of syndecans to facilitate the transfer of virus from epithelial to immune cells and decreased cell proliferation. The latter could impede the ability to maintain an effective epithelial barrier and adversely impact immune cell function. However, these responses were observed primarily following exposure to high (15-150 μg/ml) MPA concentrations. Clinical correlation is needed to determine whether the prolonged MPA exposure associated with contraception activates these mechanisms in vivo.

  2. Antagonism by idazoxan at low dose but not high dose, of the natriuretic action of moxonidine.

    OpenAIRE

    D. R. Allan; Penner, S. B.; Smyth, D. D.

    1996-01-01

    1. Recent studies concerning the imidazoline receptor have utilized idazoxan as a specific imidazoline receptor antagonist. The aim of the present study was to describe the in vivo effects of various doses of idazoxan on renal function, in the presence and absence of moxonidine, an I1 imidazoline receptor agonist. 2. In anaesthetized, unilaterally nephrectomized (7 to 10 days) Sprague Dawley rats, an intrarenal infusion of moxonidine (3 nmol kg-1 min-1) increased urine flow rate, sodium excre...

  3. Chemotherapy of onchocerciasis with high doses of diethylcarbamazine or a single dose of ivermectin: microfilaria levels and side effects.

    Science.gov (United States)

    Albiez, E J; Newland, H S; White, A T; Kaiser, A; Greene, B M; Taylor, H R; Büttner, D W

    1988-03-01

    Fifty adult male subjects with moderate to heavy onchocerciasis from the Liberian rain forest were selected for a double-blind placebo-controlled chemotherapy study. The effects of high doses of diethylcarbamazine (DEC) - 30 mg/kg/d - over one week preceded by a one week initial treatment with normal oral doses of DEC or DEC lotion were compared with a single dose of ivermectin (150 micrograms/kg) and placebo. During the initial treatment DEC tablets or lotion caused distinctly more frequent and severe reactions than did invermectin. The reactions to ivermectin did not differ from those of the placebo patients. High doses of DEC caused, in about half of the patients, headache, dizziness, nausea or vomiting. DEC markedly increased the number of corneal microfilariae and of corneal opacities compared to ivermectin. All changes resolved with a return to pretreatment findings two months after treatment. The three treatment groups showed no differences at the ten months follow-up. In all treated patients skin microfilaria counts fell almost to zero by the end of the two week therapy. In the ivermectin group microfilaria counts remained significantly lower than in the DEC patients at the two and ten months examinations. In summary, ivermectin was much better tolerated than DEC and had a longer lasting effect on the microfilariae in the skin. Since high doses of DEC were less effective and caused more frequent and severe side effects, this approach cannot be recommended for treatment of onchocerciasis.

  4. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  5. Biological impact of high-dose and dose-rate radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Maliev, V.; Popov, D. [Russian Academy of Science, Vladicaucas (Russian Federation); Jones, J.; Gonda, S. [NASA -Johnson Space Center, Houston (United States); Prasad, K.; Viliam, C.; Haase, G. [Antioxida nt Research Institute, Premier Micronutrient Corporation, Novato (United States); Kirchin, V. [Moscow State Veterinary and Biotechnology Acade my, Moscow (Russian Federation); Rachael, C. [University Space Research Association, Colorado (United States)

    2006-07-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  6. Cytogenetic dose-response in vitro for biological dosimetry after exposure to high doses of gamma-rays.

    Science.gov (United States)

    Vinnikov, Volodymyr A; Maznyk, Nataliya A

    2013-04-01

    The dose response for dicentrics plus centric rings and total unstable chromosome-type aberrations was studied in the first mitoses of cultured human peripheral blood lymphocytes irradiated in vitro to doses of ∼2, 4, 6, 8, 10, 16 and 20 Gy of acute (60)Со gamma-rays. A dose-dependent increase of aberration yield was accompanied by a tendency to the underdispersion of dicentrics and centric rings among cells distributions compared with Poisson statistics at doses ≥6 Gy. The formal fitting of the data to a linear-quadratic model resulted in an equation with the linear and quadratic coefficients ranged 0.098-0.129×cell(-1)×Gy(-1) and 0.039-0.034×cell(-1)×Gy(-2), respectively, depending on the fitting method. The actual radiation-induced aberration yield was markedly lower than expected from a calibration curve, generated earlier within a lower dose range. Interlaboratory variations in reported dicentric yields induced by medium-to-high radiation doses in vitro are discussed.

  7. Effectiveness of High Dose Pralidoxime for Treatment of Organophosphate Poisoning

    Directory of Open Access Journals (Sweden)

    Pham Due

    2014-09-01

    Full Text Available Background: For effective treatment of organophosphate (OP poisoning, development of a standardized protocol with flexible dose regimen for atropine and pralidoxime is an essential step. In this study, we aimed to assess the protocol devised in our setting; Bach Mai Hospital Poison Treatment Center, for treatment of OP poisoning that included a higher dose regimen of pralidoxime (2PAM. Methods: A protocol for treatment of OP poisoning was developed during 1995 to 1996, which included an atropinization scoring scale and a modification of 2PAM dose regimen. In this study, OP poisoned patients who were treated during 1997 to 2002 with the new protocol (study group or cases were compared with historical control group which included OP poisoned patients treated between 1993 and 1994 prior to establishment of the new protocol. Results: One-hundred and eight cases and 54 controls were included. The cases and controls were not significantly different according to age, gender and plasma cholinesterase activity on admission from each other. There was no significant difference of mean duration of 2PAM therapy between the two groups. The controls received mean total 2PAM dose of 7.2±4.1 g, while the patients in the study group received 20.0±12.7 g which was 2.77 times higher than the dose for control group (P

  8. High-Dose-Rate Prostate Brachytherapy Consistently Results in High Quality Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    White, Evan C.; Kamrava, Mitchell R.; Demarco, John; Park, Sang-June; Wang, Pin-Chieh; Kayode, Oluwatosin; Steinberg, Michael L. [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, California (United States); Demanes, D. Jeffrey, E-mail: jdemanes@mednet.ucla.edu [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, California (United States)

    2013-02-01

    Purpose: We performed a dosimetry analysis to determine how well the goals for clinical target volume coverage, dose homogeneity, and normal tissue dose constraints were achieved with high-dose-rate (HDR) prostate brachytherapy. Methods and Materials: Cumulative dose-volume histograms for 208 consecutively treated HDR prostate brachytherapy implants were analyzed. Planning was based on ultrasound-guided catheter insertion and postoperative CT imaging; the contoured clinical target volume (CTV) was the prostate, a small margin, and the proximal seminal vesicles. Dosimetric parameters analyzed for the CTV were D90, V90, V100, V150, and V200. Dose to the urethra, bladder, bladder balloon, and rectum were evaluated by the dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} of each organ, expressed as a percentage of the prescribed dose. Analysis was stratified according to prostate size. Results: The mean prostate ultrasound volume was 38.7 {+-} 13.4 cm{sup 3} (range: 11.7-108.6 cm{sup 3}). The mean CTV was 75.1 {+-} 20.6 cm{sup 3} (range: 33.4-156.5 cm{sup 3}). The mean D90 was 109.2% {+-} 2.6% (range: 102.3%-118.4%). Ninety-three percent of observed D90 values were between 105 and 115%. The mean V90, V100, V150, and V200 were 99.9% {+-} 0.05%, 99.5% {+-} 0.8%, 25.4% {+-} 4.2%, and 7.8% {+-} 1.4%. The mean dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} for organs at risk were: Urethra: 107.3% {+-} 3.0%, 101.1% {+-} 14.6%, and 47.9% {+-} 34.8%; bladder wall: 79.5% {+-} 5.1%, 69.8% {+-} 4.9%, and 64.3% {+-} 5.0%; bladder balloon: 70.3% {+-} 6.8%, 59.1% {+-} 6.6%, and 52.3% {+-} 6.2%; rectum: 76.3% {+-} 2.5%, 70.2% {+-} 3.3%, and 66.3% {+-} 3.8%. There was no significant difference between D90 and V100 when stratified by prostate size. Conclusions: HDR brachytherapy allows the physician to consistently achieve complete prostate target coverage and maintain normal tissue dose constraints for organs at risk over a wide range of target volumes.

  9. Medication error - Inadvertent high dose intradermal cloxacillin induced skin necrosis

    Directory of Open Access Journals (Sweden)

    Adithan Surendiran

    2012-01-01

    Full Text Available Medication error is one of the important causes of preventable adverse drug reactions. It can occur in the form of administration of a wrong drug, in the wrong dose, to the wrong patient, in an unsuitable dosage form, for the wrong duration or by using an inappropriate route of administration. Intradermal skin testing for cloxacillin hypersensitivity is done at low doses to check for drug allergy. In this report, three patients were given 50 times higher dose of cloxacillin than recommended for skin testing, resulting in pain and necrosis at the site of injection. The error occurred due to wrong dilution of the drug as done by a nursing intern. Some reasons for this could be overtime working, under trained staff, unsupervised nursing interns, complicated and unclear protocols, interpersonal communication gap between health care professionals and also poor availability of ideal resources. Pharmacovigilance centers must alert health care professionals about the significance of reporting medication errors through bulletins and journals.

  10. ``In Vivo'' Dosimetry in High Dose Rate Brachytherapy for Cervical Cancer Treatments

    Science.gov (United States)

    González-Azcorra, S. A.; Mota-García, A.; Poitevín-Chacón, M. A.; Santamaría-Torruco, B. J.; Rodríguez-Ponce, M.; Herrera-Martínez, F. P.; Gamboa de Buen, I.; Ruíz-Trejo, C.; Buenfil, A. E.

    2008-08-01

    In this prospective study, rectal dose was measured "in vivo" using TLD-100 crystals (3×3×1 mm3), and it has been compared to the prescribed dose. Measurements were performed in patients with cervical cancer classified in FIGO stages IB-IIIB and treated with high dose rate brachytherapy (HDR BT) at the Instituto Nacional de Cancerología (INCan).

  11. Pharmacodynamic effects of standard dose prasugrel versus high dose clopidogrel in non-diabetic obese patients with coronary artery disease.

    Science.gov (United States)

    Darlington, Andrew; Tello-Montoliu, Antonio; Rollini, Fabiana; Ueno, Masafumi; Ferreiro, José Luis; Patel, Ronakkumar; Desai, Bhaloo; Guzman, Luis A; Bass, Theodore A; Angiolillo, Dominick J

    2014-02-01

    Increased body weight is independently associated with impaired clopidogrel pharmacodynamic (PD) response. Prasugrel has more potent PD effects compared with clopidogrel, although its PD effects in obese patients are unknown. The aim of this prospective, randomised, study was to compare the PD effects of standard-dose prasugrel [60 mg loading dose (LD)/10 mg daily maintenance dose (MD)] with high-dose clopidogrel (900 mg LD/150 mg daily MD) in non-diabetic obese [body mass index (BMI) ≥30 kg/m²] patients, with coronary artery disease (CAD) on aspirin therapy. PD assessments (baseline, 2 hours post-LD and 6 ± 2 days after MD) were conducted using four platelet function assays, and the platelet reactivity index (PRI) assessed by VASP was used for sample size estimation. A total of 42 patients with a BMI of 36.42 ± 5.6 kg/m² completed the study. There were no differences in baseline PD measures between groups. At 2 hours post-LD, prasugrel was associated with lower PRI compared with clopidogrel (24.3 ± 5.5 vs 58.7 ± 5.7, p≤0.001), with consistent findings for all assays. At one-week, PRI values on prasugrel MD were lower than clopidogrel MD without reaching statistical significance (34.7 ± 5.8 vs 42.9 ± 5.8, p=0.32), with consistent findings for all assays. Accordingly, rates of high on-treatment platelet reactivity were markedly reduced after prasugrel LD, but not after MD. In conclusion, in non-diabetic obese patients with CAD, standard prasugrel dosing achieved more potent PD effects than high-dose clopidogrel in the acute phase of treatment, but this was not sustained during maintenance phase treatment. Whether an intensified prasugrel regimen is required in obese patients warrants investigation.

  12. Treatment of advanced soft-tissue sarcomas using a combined strategy of high-dose ifosfamide, high-dose doxorubicin and salvage therapies.

    Science.gov (United States)

    Leyvraz, S; Herrmann, R; Guillou, L; Honegger, H P; Christinat, A; Fey, M F; Sessa, C; Wernli, M; Cerny, T; Dietrich, D; Pestalozzi, B

    2006-11-20

    Having determined in a phase I study the maximum tolerated dose of high-dose ifosfamide combined with high-dose doxorubicin, we now report the long-term results of a phase II trial in advanced soft-tissue sarcomas. Forty-six patients with locally advanced or metastatic soft-tissue sarcomas were included, with age or =3 neutropenia in 59%, thrombopenia in 39% and anaemia in 27% of cycles. Three patients experienced grade 3 neurotoxicity and one patient died of septic shock. This high-dose regimen is toxic but nonetheless feasible in multicentre settings in non elderly patients with good performance status. A high response rate was obtained. Prolonged survival was mainly a function of salvage therapies.

  13. Isoniazid overdose treated with high-dose pyridoxine.

    Science.gov (United States)

    Yarbrough, B E; Wood, J P

    1983-05-01

    Large doses of pyridoxine recently have been shown to prevent the seizures and acidosis caused by ingestion of more than two to three grams of isoniazid. We present three cases of massive isoniazid ingestion, producing seizures and acidosis, that were treated successfully by administration of one gram of pyridoxine intravenously for each gram of isoniazid ingested.

  14. Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

    Directory of Open Access Journals (Sweden)

    Seyed Mohsen Hosseini Daghigh

    2012-03-01

    Full Text Available Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phantom was built in order to be inserted by various sizes of esophageal applicators. EDR2 films were placed at 33 mm from Ir-192 source and irradiated with 1.5 Gy after planning using treatment planning system for all applicators. Results The results of film dosimetry in reference point for 6, 8, 10, and 20 mm applicators were 1.54, 1.53, 1.48, and 1.50 Gy, respectively. The difference between practical and treatment planning system results was 0.023 Gy (

  15. Irradiation dose and temperature dependence of fracture toughness in high dose HT9 steel from the fuel duct of FFTF

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Thak Sang; Toloczko, Mychailo B.; Saleh, Tarik A.; Maloy, Stuart A.

    2013-01-14

    To expand the knowledge base for fast reactor core materials, fracture toughness has been evaluated for high dose HT9 steel using miniature disk compact tension (DCT) specimens. The HT9 steel DCT specimens were machined from the ACO-3 fuel duct of the Fast Flux Test Facility (FFTF), which achieved high doses in the range of 3–148 dpa at 378–504 C. The static fracture resistance (J-R) tests have been performed in a servohydraulic testing machine in vacuum at selected temperatures including room temperature, 200 C, and each irradiation temperature. Brittle fracture with a low toughness less than 50 MPa pm occurred in room temperature tests when irradiation temperature was below 400 C, while ductile fracture with stable crack growth was observed when irradiation temperature was higher. No fracture toughness less than 100 MPa pm was measured when the irradiation temperature was above 430 C. It was shown that the influence of irradiation temperature was dominant in fracture toughness while the irradiation dose has only limited influence over the wide dose range 3–148 dpa. A slow decrease of fracture toughness with test temperature above room temperature was observed for the nonirradiated and high temperature (>430 *C) irradiation cases, which indicates that the ductile–brittle transition temperatures (DBTTs) in those conditions are lower than room temperature. A comparison with the collection of existing data confirmed the dominance of irradiation temperature in the fracture toughness of HT9 steels.

  16. A Real World Report on Intravenous High-Dose and Non-High-Dose Proton-Pump Inhibitors Therapy in Patients with Endoscopically Treated High-Risk Peptic Ulcer Bleeding

    Directory of Open Access Journals (Sweden)

    Lung-Sheng Lu

    2012-01-01

    Full Text Available Background and Study Aims. The optimal dose of intravenous proton-pump inhibitor (PPI therapy for the prevention of peptic ulcer (PU rebleeding remains controversial. This study aimed to understand the real world experiences in prescribing high-dose PPI and non-high-dose PPI for preventing rebleeding after endoscopic treatment of high-risk PU. Patients and Methods. A total of 220 subjects who received high-dose and non-high-dose pantoprazole for confirmed acute PU bleeding that were successfully treated endoscopically were enrolled. They were divided into rebleeding (n=177 and non-rebleeding groups (n=43. Randomized matching of the treatment-control group was performed. Patients were randomly selected for non-high-dose and high-dose PPI groups (n=44 in each group. Results. Univariate analysis showed, significant variables related to rebleeding were female, higher creatinine levels, and higher Rockall scores (≧6. Before case-control matching, the high-dose PPI group had higher creatinine level, higher percentage of shock at presentation, and higher Rockall scores. After randomized treatment-control matching, no statistical differences were observed for rebleeding rates between the high-dose and non-high-dose groups after case-control matching. Conclusion. This study suggests that intravenous high-dose pantoprazole may not be superior to non-high-dose regimen in reducing rebleeding in high-risk peptic ulcer bleeding after successful endoscopic therapy.

  17. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  18. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxis......) 4.5 microg (F4.5) or terbutaline (Bricanyl) 500 microg (T500) were inhaled cumulatively via a dry powder inhaler (Turbuhaler) over 1 h (three patients) or 2.5 h (17 patients) and compared to a day of no treatment, in a randomised, double-blind (active treatments only), crossover trial. Blood...... pressure (BP), ECG, plasma potassium, glucose, lactate, and adverse events were monitored up to 10 h to assess tolerability and relative systemic dose potency. RESULTS: Formoterol and terbutaline had significant beta2-adrenergic effects on most outcomes. Apart from the effect on systolic BP, QRS duration...

  19. Dose dense (CEOP-14) vs dose dense and rituximab (CEOP-14 +R) in high-risk diffuse large cell lymphoma.

    Science.gov (United States)

    Avilés, Agustin; Nambo, María J; Neri, Natividad; Cleto, Sergio; Castañeda, Claudia; Huerta-Guzmàn, Judith; Murillo, Edgar; Contreras, Margarita; Talavera, Alejandra; González, Martha

    2007-01-01

    To assess efficacy and toxicity of rituximab and dose chemotherapy in high-risk diffuse large cell lymphoma, we conducted a controlled clinical trial to assess efficacy and toxicity of a dose-dense regimen CEOP- 14 (cyclophosphamide, epirubicin, vincristine, and prednisone every 14 d) compared to CEOP-14 plus rituximab. One hundred and ninety-six patients were randomized to received CEOP-rituximab (cyclophosphamide 1500 mg/m2, epirubicin 120 mg/m2, vincristine, and prednisone at standard dose and rituximab at 375 mg/m2) compared with the same chemotherapy administered every 14 d (CEOP-14). In an intent-to-treat analysis all patients were available for efficacy and toxicity. Complete response in CEOP-14 was observed in 73 cases (74%) and in 75 patients (76%) in the CEOP-R regimen (76%) (p = 0.8). With a median follow-up of 53.4 mo, median has not been reached in time to tumor-progression (TTP) and overall survival (OS). Actuarial curves at 5 yr showed that TTP and OS in patients treated with CEOP-R were 74% and 67%, respectively, that were not statistical different when compared to CEOP-14, 72% and 65%, respectively (p = 0.8). Acute toxicity was mild and well tolerated. The use of a dense-dose regimen is useful and well tolerated in patients with very high risk diffuse large cell lymphoma. The addition of rituximab did not improve outcome in these setting of patients.

  20. High-dose lidocaine does not affect defibrillation efficacy: implications for defibrillation mechanisms.

    Science.gov (United States)

    Ujhelyi, M R; Sims, J J; Miller, A W

    1998-04-01

    This study assessed the effect of low (10 mg.kg-1.h-1) and very high (18 mg.kg-1.h-1) doses of lidocaine on defibrillation energy requirements (DER) to relate changes in indexes of sodium-channel blockade with changes in DER values using a dose-response study design. In group 1 (control; n = 6 pigs), DER values were determined at baseline and during treatment with 5% dextrose in water (D5W) and with D5W added to D5W. In group 2 (n = 7), DER values were determined at baseline and during treatment with low-dose lidocaine followed by high-dose lidocaine. In group 3 (n = 3), DER values were determined at baseline and high-dose lidocaine. Group 3 controlled for the order of lidocaine treatment with the addition of high-dose lidocaine after baseline. DER values in group 1 did not change during D5W. In group 2, low-dose lidocaine increased DER values by 51% (P = 0.01), whereas high-dose lidocaine added to low-dose lidocaine reduced DER values back to within 6% of baseline values (P = 0.02, low dose vs. high dose). DER values during high-dose lidocaine in group 3 also remained near baseline values (16.2 +/- 2.7 to 12.9 +/- 2.7 J), demonstrating that treatment order had no impact on group 2. Progressive sodium-channel blockade was evident as incremental reduction in ventricular conduction velocity as the lidocaine dose increased. Lidocaine also significantly increased ventricular fibrillation cycle length as the lidocaine dose increased. However, the greatest increase in DER occurred when ventricular fibrillation cycle length was minimally affected, demonstrating a negative correlation (P = 0.04). In summary, lidocaine has an inverted U-shaped DER dose-response curve. At very high lidocaine doses, DER values are similar to baseline and tend to decrease rather than increase. Increased refractoriness during ventricular fibrillation may be the electrophysiological mechanism by which high-dose lidocaine limits the adverse effects that low-dose lidocaine has on DER values

  1. High Dose Vaginal Misoprostol Versus Concentrated Oxytocin + Low Dose Vaginal Misoprostol for Mid-Trimester Labor Induction: A Randomized Trial

    Science.gov (United States)

    Nuthalapaty, Francis S.; Ramsey, Patrick S.; Biggio, Joseph R.; Owen, John

    2013-01-01

    Objective To compare the efficacy and side effects of a high-dose vaginal misoprostol regimen to concentrated intravenous oxytocin plus low-dose vaginal misoprostol for mid-trimester labor induction. Study Design Women at 14-24 weeks, with obstetric or fetal indications for delivery and no prior cesarean, were randomly assigned to receive either vaginal misoprostol 600 μg ×1, then 400 μg q 4 hr × 5 (Group 1) or escalating-dose concentrated oxytocin infusions (277-1667 mU/min) plus vaginal misoprostol 400 μg × 1, then 200 μg q 6 hr × 2, then 100 μg × 1 (Group 2). Analysis was by intent to treat. Primary outcomes were live birth rate and induction-to-delivery interval. Results The intended sample size was 70 women per group; however, the trial was terminated at the initial interim analysis due to a highly significant difference in one of the primary study outcomes. Twenty women were assigned to Group 1 and 18 were assigned to the Group 2. Median induction-to-delivery interval was significantly shorter in Group 1 (12 hr, range 4 - 44 hr) versus Group 2 (18 hr, range 7 - 36 hr; p=0.01). Induction success rate at 12 hours was significantly higher in the Group 1 (60%), compared to Group 2 (22%, p=.02). No significant difference was noted in the live birth rate between Group 1 and 2 (13%, 0%, p = 0.16). The incidence of retained placenta requiring curettage, chorioamnionitis, intrapartum fever, nausea, emesis, and diarrhea were similar between both groups. Conclusion Compared to concentrated oxytocin plus low-dose vaginal misoprostol, high-dose vaginal misoprostol significantly shortens mid-trimester labor inductions. PMID:16157113

  2. The effects of high-dose ivermectin regimens on Onchocerca volvulus in onchocerciasis patients.

    Science.gov (United States)

    Awadzi, K; Attah, S K; Addy, E T; Opoku, N O; Quartey, B T

    1999-01-01

    Ivermectin, at the standard dose of 150 micrograms/kg bodyweight, does not kill the adult worms of Onchocerca volvulus and does not disrupt embryogenesis or spermatogenesis. Repeated standard doses, if maintained, arrest microfilarial production but result in only a mild-to-modest macrofilaricidal effect. We investigated whether high doses would effectively kill the adult worms, and whether cessation of microfilarial production could be reproduced by an equivalent, single, high dose. One hundred men participated in a double-blind placebo-controlled trial and received increasing doses of ivermectin from 150 micrograms/kg to 1600 micrograms/kg bodyweight. Nodules were excised at day 180 and examined by histopathology. Total doses of ivermectin up to 1600 micrograms/kg were not significantly more effective than 150 micrograms/kg. Moreover, they did not reproduce the marked inhibitory effects of the repeat standard-dose regimens on embryogenesis, nor the modest effect on adult worm viability, at comparable total doses. These effects may be functions of multiplicities of dosages rather than of the total dose. Our findings also suggest that repeated high-dose regimens are unlikely to be more effective than a similar number of 150 micrograms/kg doses. This deficiency of ivermectin requires that the search for macrofilaricides remains a top priority.

  3. Effects of low dose gamma radiation on the early growth of red pepper and the resistance to subsquent high dose of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Baek, M. H.; Kim, D. H.; Lee, Y. K. [KAERI, Taejon (Korea, Republic of); Lee, Y. B. [Chungnam National Univ., Taejon (Korea, Republic of)

    2001-05-01

    Red pepper (capsicum annuum L. cv. Jokwang and cv. Johong) seeds were irradiated with the dose of 0{approx}50 Gy to investigated the effect of the low dose gamma radiation on the early growth and resistance to subsequent high dose of radiation. The effect of the low dose gamma radiation on the early growth and resistance to subsequenct high dose of radiation were enhanced in Johong cultivar but not in Jokwang cultivar. Germination rate and early growth of Johong cultivar were noticeably increased at 4 Gy-, 8 Gy- and 20 Gy irradiation group. Resistance to subsequent high dose of radiation of Johong cultivar were increased at almost all of the low dose irradiation group. Especially it was highest at 4 Gy irradiation group. The carotenoid contents and enzyme activity on the resistance to subsequent high dose of radiation of Johong cultivar were increased at the 4 Gy and 8 Gy irradiation group.

  4. High dose of ascorbic acid induces cell death in mesothelioma cells.

    Science.gov (United States)

    Takemura, Yukitoshi; Satoh, Motohiko; Satoh, Kiyotoshi; Hamada, Hironobu; Sekido, Yoshitaka; Kubota, Shunichiro

    2010-04-02

    Malignant mesothelioma is an asbestos-related fatal disease with no effective cure. Recently, high dose of ascorbate in cancer treatment has been reexamined. We studied whether high dose of ascorbic acid induced cell death of four human mesothelioma cell lines. High dose of ascorbic acid induced cell death of all mesothelioma cell lines in a dose-dependent manner. We further clarified the cell killing mechanism that ascorbic acid induced reactive oxygen species and impaired mitochondrial membrane potential. In vivo experiment, intravenous administration of ascorbic acid significantly decreased the growth rate of mesothelioma tumor inoculated in mice. These data suggest that ascorbic acid may have benefits for patients with mesothelioma.

  5. Ceramic Matrix Composites Performances Under High Gamma Radiation Doses

    Science.gov (United States)

    Cemmi, A.; Baccaro, S.; Fiore, S.; Gislon, P.; Serra, E.; Fassina, S.; Ferrari, E.; Ghisolfi, E.

    2014-06-01

    Ceramic matrix composites reinforced by continuous ceramic fibers (CMCs) represent a class of advanced materials developed for applications in automotive, aerospace, nuclear fusion reactors and in other specific systems for harsh environments. In the present work, the silicon carbide/silicon carbide (SiCf/SiC) composites, manufactured by Chemical Vapour Infiltration process at FN S.p.A. plant, have been evaluated in term of gamma radiation hardness at three different absorbed doses (up to around 3MGy). Samples behavior has been investigated before and after irradiation by means of mechanical tests (flexural strength) and by surface and structural analyses (X-ray diffraction, SEM, FTIR-ATR, EPR).

  6. Single high-dose pyridoxine treatment for isoniazid overdose.

    Science.gov (United States)

    Wason, S; Lacouture, P G; Lovejoy, F H

    1981-09-04

    We treated five isoniazid-overdosed patients each with a single dose of pyridoxine hydrochloride equivalent to the gram amount of isoniazid ingested and compared their outcome with that of 41 patients from the literature who received little or no pyridoxine. Recurrent seizures occurred in 60% of patients who had received no pyridoxine vs 0% in our patients. Metabolic acidosis resolved in our cases but was refractory in the literature cases. In our cases, coma lightened more rapidly and was of shorter duration as compared with that in the literature cases (mean, seven hours vs 24 hours). No adverse effects of pyridoxine were seen in our patients.

  7. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy.

    Science.gov (United States)

    Lahanas, M; Baltas, D; Zamboglou, N

    2003-02-07

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives.

  8. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lahanas, M [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Baltas, D [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Zamboglou, N [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany)

    2003-02-07

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives.

  9. Radiation Sialadenitis Induced by High-dose Radioactive Iodine Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Shin Young; Lee, Jaetae [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2010-06-15

    Radioactive iodine ({sup 131}I) is accumulated in the thyroid tissue and plays an important role in the treatment of differentiated papillary and follicular cancers after thyroidectomy. Simultaneously, {sup 131}I is concentrated in the salivary glands and secreted into the saliva. Dose-related damage to the salivary parenchyma results from the {sup 131}I irradiation. Salivary gland swelling and pain, usually involving the parotid, can be seen. The symptoms may develop immediately after a therapeutic dose of {sup 131}I and/or months later and progress in intensity with time. In conjunction with the radiation sialadenitis, secondary complications reported include xerostomia, taste alterations, infection, increases in caries, facial nerve involvement, candidiasis, and neoplasia. Prevention of {sup 131}I sialadenitis may involve the use of sialogogic agents to hasten the transit time of the radioactive iodine through the salivary glands. However, studies are not available to delineate the efficacy of this approach. Treatment of the varied complications that may develop encompass numerous approaches and include gland massage, sialogogic agents, duct probing, antibiotics, mouthwashes, good oral hygiene, and adequate hydration. Recently interventional sialoendoscopy has been introduced an effective tool for the management of patients with {sup 131}I-induced sialadenitis that is unresponsive to medical treatment.

  10. Elimination of ascorbic acid after high-dose infusion in prostate cancer patients

    DEFF Research Database (Denmark)

    Nielsen, Torben Kjær; Højgaard, Martin; Andersen, Jon Thor Trærup

    2015-01-01

    Treatment with high-dose intravenous (IV) ascorbic acid (AA) is used in complementary and alternative medicine for various conditions including cancer. Cytotoxicity to cancer cell lines has been observed with millimolar concentrations of AA. Little is known about the pharmacokinetics of high dose...

  11. High daily doses of benzodiazepines among Quebec seniors: prevalence and correlates

    Directory of Open Access Journals (Sweden)

    Moride Yola

    2001-11-01

    Full Text Available Abstract Background Use of high daily doses of benzodiazepines is generally contraindicated for seniors. While both patient and physician factors may influence the use of high daily doses, previous research on the effect of patient factors has been extremely limited. The objectives of this study were to determine the one year prevalence of use of high daily doses of benzodiazepines, and examine physician and patient correlates of such use among Quebec community-dwelling seniors. Methods Patient information for 1423 community-dwelling Quebec seniors who participated in the Canadian Study of Health and Aging was linked to provincial health insurance administrative data bases containing detailed information on prescriptions received and prescribers. Results The standardized one year period prevalence of use of high daily doses of benzodiazepines was 7.9%. Use of high daily doses was more frequent among younger seniors and those who had reported anxiety during the previous year. Patients without cognitive impairment were more likely to receive high dose prescriptions from general practitioners, while those with cognitive impairment were more likely to receive high dose prescriptions from specialists. Conclusion High dose prescribing appears to be related to both patient and physician factors.

  12. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  13. High- and low-dose expectancies as mediators of personality dimensions and alcohol involvement.

    Science.gov (United States)

    Read, Jennifer P; O'Connor, Roisin M

    2006-03-01

    The present study examined the influences of personality dimensions (extraversion, neuroticism) on college alcohol involvement both (1) directly and (2) mediated by positive and negative alcohol expectancies across two imagined (high and low) alcohol doses. Participants (N = 339; 176 women) were regularly drinking college students who completed a questionnaire battery on demographic characteristics, personality, expectancies, and alcohol use and problems. Structural equation modeling analysis of low- and high-dose models revealed partial support for the Social Learning Theory conceptualization of expectancies as mediators of more distal (personality) influences. Interestingly, patterns of association differed by dose. At high-expectancy doses, positive alcohol expectancies fully mediated the extraversion-use association. At low doses, positive expectancies did not play a critical role. Two distinct pathways from neuroticism to alcohol use were observed: a direct pathway, whereby neuroticism is a protective factor for alcohol use, and an indirect pathway, through positive expectancies, whereby neuroticism is a risk factor. The protective pathway was evident regardless of expectancy doses, whereas the risk pathway was evident only at high doses. Negative expectancies partially mediated the association between neuroticism and alcohol problems at both high- and low-expectancy doses. These data underscore the unique role of both positive and negative expectancies in the association between personality and drinking behavior and point to the importance of considering alcohol dose when assessing expectancies. Findings suggest that it may be beliefs about the effects resulting from heavy (rather than moderate) drinking that may be the active mechanism underlying drinking behavior.

  14. Efficacy of Continuous High Dose Midazolam Infusion in Childhood Refractory Generalized Convulsive Status Epilepticus

    Directory of Open Access Journals (Sweden)

    Afshin Fayyazi

    2011-06-01

    Full Text Available bjeciveProlonged and uncontrolled refractory status epilepticus (SE is a life-threatening medical emergency in children (1,2,3. There is no consensus on the optimal therapy for refractory status epilepticus (1. The aim of this study was to develop a new method for treating patients with refractory status epilepticus.Materials & MethodsTen children with refractory status epilepticus in Mofid Hospital, who did not respond to 10 μg/kg per min of intravenous midazolam, had their dose of midazolam increased to 30 μg/kg per min. All children were monitored for the development of side effects.ResultsTen children with no response to low-dose midazolam were given a higher dose of midazolam, and 5 (50% children had a good response. These patients had significantly different response to high-dose midazolam.One patient in the high-dose midazolam group was intubated and required mechanical ventilation. The duration of stay in the hospital and PICU and on mechanical ventilation in patients with no response to low-dose midazolam following with other drugs was longer than in the high-dose midazolam group.No death occurred in high dose midazolam group.ConclusionHigh-midazolam dose drip infusion is a safe and effective protocol for refractory status epilepticus in children.

  15. High frequency of streptococcal bacteraemia during childhood AML therapy irrespective of dose of cytarabine

    DEFF Research Database (Denmark)

    Johannsen, Katrine Helle; Handrup, Mette Møller; Lausen, Birgitte Frederiksen

    2013-01-01

    BACKGROUND: High-dose cytarabine has been associated with a high frequency of viridans group streptococcal (VGS) bacteraemia. VGS bacteraemia causes considerable morbidity and mortality. The Nordic Society of Paediatric Haematology and Oncology (NOPHO)-AML protocols use higher cumulated doses...... following courses with low-dose cytarabine versus courses with high-dose cytarabine. CONCLUSIONS: VGS were the most commonly isolated pathogens causing the most severe infections and the majority of life-threatening infections. A substantial proportion of the strains were resistant to penicillin. The high...... rate of VGS seemed independent of high-dose cytarabine but was more likely caused by the intensive chemotherapy treatment leading to severe mucositis and neutropenia....

  16. Irradiation dose and temperature dependence of fracture toughness in high dose HT9 steel from the fuel duct of FFTF

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Thak Sang, E-mail: byunts@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Toloczko, Mychailo B. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Saleh, Tarik A.; Maloy, Stuart A. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2013-01-15

    To expand the knowledge base for fast reactor core materials, fracture toughness has been evaluated for high dose HT9 steel using miniature disk compact tension (DCT) specimens. The HT9 steel DCT specimens were machined from the ACO-3 fuel duct of the Fast Flux Test Facility (FFTF), which achieved high doses in the range of 3-148 dpa at 378-504 Degree-Sign C. The static fracture resistance (J-R) tests have been performed in a servohydraulic testing machine in vacuum at selected temperatures including room temperature, 200 Degree-Sign C, and each irradiation temperature. Brittle fracture with a low toughness less than 50 MPa {radical}m occurred in room temperature tests when irradiation temperature was below 400 Degree-Sign C, while ductile fracture with stable crack growth was observed when irradiation temperature was higher. No fracture toughness less than 100 MPa {radical}m was measured when the irradiation temperature was above 430 Degree-Sign C. It was shown that the influence of irradiation temperature was dominant in fracture toughness while the irradiation dose has only limited influence over the wide dose range 3-148 dpa. A slow decrease of fracture toughness with test temperature above room temperature was observed for the nonirradiated and high temperature (>430 Degree-Sign C) irradiation cases, which indicates that the ductile-brittle transition temperatures (DBTTs) in those conditions are lower than room temperature. A comparison with the collection of existing data confirmed the dominance of irradiation temperature in the fracture toughness of HT9 steels.

  17. Characterisation of high dose dry powder aerosols by cascade impaction and laser diffraction analysis

    NARCIS (Netherlands)

    Grasmeijer, F.; Hagedoorn, P.; Frijlink, H.W.; De Boer, A.H.

    2011-01-01

    Background: Developments in high dose dry powder inhalationcontinue to challenge the viability of pharmacopoeialmethods for drug aerosol characterisation. Especiallythe occurrence of bounce effects can cause the amount offines (<1 lm) to be highly overestimated in particle sizedistributions (PSDs) o

  18. The linear-quadratic model is inappropriate to model high dose per fraction effects in radiosurgery.

    Science.gov (United States)

    Kirkpatrick, John P; Meyer, Jeffrey J; Marks, Lawrence B

    2008-10-01

    The linear-quadratic (LQ) model is widely used to model the effect of total dose and dose per fraction in conventionally fractionated radiotherapy. Much of the data used to generate the model are obtained in vitro at doses well below those used in radiosurgery. Clinically, the LQ model often underestimates tumor control observed at radiosurgical doses. The underlying mechanisms implied by the LQ model do not reflect the vascular and stromal damage produced at the high doses per fraction encountered in radiosurgery and ignore the impact of radioresistant subpopulations of cells. The appropriate modeling of both tumor control and normal tissue toxicity in radiosurgery requires the application of emerging understanding of molecular-, cellular-, and tissue-level effects of high-dose/fraction-ionizing radiation and the role of cancer stem cells.

  19. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  20. Infused vincristine and adriamycin with high dose methylprednisolone (VAMP) in advanced previously treated multiple myeloma patients.

    Science.gov (United States)

    Forgeson, G. V.; Selby, P.; Lakhani, S.; Zulian, G.; Viner, C.; Maitland, J.; McElwain, T. J.

    1988-01-01

    Forty-five patients with relapsed or refractory multiple myeloma received continuous infusions of vincristine (0.4 mg total dose daily for 4 days) and adriamycin (9 mg m-2 daily for 4 days) with a high dose of methylprednisolone (1 g m-2 i.v. or p.o. daily by 1 h infusion), the VAMP regimen. Sixteen (36%) responded, with a median duration of remission of 11 months and median survival of 20 months. Major toxicities encountered were infective and cardiovascular. Two smaller groups of myeloma patients were treated with high dose methylprednisolone (HDMP) alone, or VAMP plus weekly low dose cyclophosphamide (Cyclo-VAMP). HDMP produced short responses in 25% of patients with less toxicity than VAMP. Cyclo-VAMP was used in a highly selected group of patients who had previously responded to high dose melphalan. It was well tolerated and produced responses in 61% of this group. PMID:3207601

  1. Escalating dose pretreatment induces pharmacodynamic and not pharmacokinetic tolerance to a subsequent high-dose methamphetamine binge.

    Science.gov (United States)

    O'Neil, Meghan L; Kuczenski, Ronald; Segal, David S; Cho, Arthur K; Lacan, Goran; Melega, William P

    2006-11-01

    A major feature of human methamphetamine (METH) abuse is the gradual dose escalation that precedes high-dose exposure. The period of escalating doses (EDs) is likely associated with development of tolerance to aspects of METH's pharmacologic and toxic effects but the relative contributions of pharmacokinetic and pharmacodynamic factors have not been well defined. In our prior studies in rats, we showed that pretreatment with an ED-METH regimen (0.1-4.0 mg/kg over 14 days) attenuated the toxicity of a subsequently administered high-dose METH binge (4 x 6 mg/kg at 2 h interval) that itself produced behavioral stereotypy, increases in core temperature, and decreases in DA system phenotypic markers in caudate-putamen (CP). Using those ED-METH and binge protocols in the present studies, pharmacokinetic and pharmacodynamic parameters that may have contributed to the apparent neuroprotection afforded by ED-METH were assessed. The ED-METH regimen itself reduced [(3)H]WIN35,428 (WIN) binding to the dopamine transporter (DAT) by 15% in CP, but did not affect DA content. During the METH binge, ED-METH pretreated animals showed attenuated increases in core temperature while concurrent microdialysis studies in CP showed a reduced DA response despite unaltered extracellular levels of METH. At 1 h after the binge, concentrations of METH and its metabolite amphetamine in brain and plasma were unaffected by the ED-METH. The results show that ED-METH pretreatment produces reductions in DAT binding and the DA response during a subsequent METH binge by altering pharmacodynamic and not pharmacokinetic parameters.

  2. Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates

    Science.gov (United States)

    Fournier, P.; Crosbie, J. C.; Cornelius, I.; Berkvens, P.; Donzelli, M.; Clavel, A. H.; Rosenfeld, A. B.; Petasecca, M.; Lerch, M. L. F.; Bräuer-Krisch, E.

    2016-07-01

    Microbeam radiation therapy (MRT) is a new radiation treatment modality in the pre-clinical stage of development at the ID17 Biomedical Beamline of the European synchrotron radiation facility (ESRF) in Grenoble, France. MRT exploits the dose volume effect that is made possible through the spatial fractionation of the high dose rate synchrotron-generated x-ray beam into an array of microbeams. As an important step towards the development of a dosimetry protocol for MRT, we have applied the International Atomic Energy Agency’s TRS 398 absorbed dose-to-water protocol to the synchrotron x-ray beam in the case of the broad beam irradiation geometry (i.e. prior to spatial fractionation into microbeams). The very high dose rates observed here mean the ion recombination correction factor, k s , is the most challenging to quantify of all the necessary corrections to apply for ionization chamber based absolute dosimetry. In the course of this study, we have developed a new method, the so called ‘current ramping’ method, to determine k s for the specific irradiation and filtering conditions typically utilized throughout the development of MRT. Using the new approach we deduced an ion recombination correction factor of 1.047 for the maximum ESRF storage ring current (200 mA) under typical beam spectral filtering conditions in MRT. MRT trials are currently underway with veterinary patients at the ESRF that require additional filtering, and we have estimated a correction factor of 1.025 for these filtration conditions for the same ESRF storage ring current. The protocol described herein provides reference dosimetry data for the associated Treatment Planning System utilized in the current veterinary trials and anticipated future human clinical trials.

  3. Acute high dose lithium-induced exacerbation of obsessive compulsive symptoms.

    Science.gov (United States)

    Umesh, Shreekantiah; Sinha, Vinod Kumar

    2014-05-01

    Obsessive compulsive disorder (OCD) is a chronic neuropsychiatric disorder whose pathophysiology is linked to serotonergic dysfunction. More recently, the role of glutamate has also been posited. Lithium is used as an adjunctive for the treatment of OCD which is found to enhance serotonergic transmission. We present a case of OCD who was on stable dose of sertraline developed exacerbation of obsessive compulsive symptoms with acute high dose of lithium but improved after dose reduction.

  4. On line high dose static position monitoring by ionization chamber detector for industrial gamma irradiators.

    Science.gov (United States)

    Rodrigues, Ary A; Vieira, Jose M; Hamada, Margarida M

    2010-01-01

    A 1 cm(3) cylindrical ionization chamber was developed to measure high doses on line during the sample irradiation in static position, in a (60)Co industrial plant. The developed ionization chamber showed to be suitable for use as a dosimeter on line. A good linearity of the detector was found between the dose and the accumulated charge, independently of the different dose rates caused by absorbing materials.

  5. A Grid Algorithm for High Throughput Fitting of Dose-Response Curve Data

    OpenAIRE

    Wang, Yuhong; Jadhav, Ajit; Southal, Noel; Huang, Ruili; Nguyen, Dac-Trung

    2010-01-01

    We describe a novel algorithm, Grid algorithm, and the corresponding computer program for high throughput fitting of dose-response curves that are described by the four-parameter symmetric logistic dose-response model. The Grid algorithm searches through all points in a grid of four dimensions (parameters) and finds the optimum one that corresponds to the best fit. Using simulated dose-response curves, we examined the Grid program’s performance in reproducing the actual values that were used ...

  6. On line high dose static position monitoring by ionization chamber detector for industrial gamma irradiators

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Ary A. [Universidade Estadual de Londrina-Depto de Fisica, Rodovia Celso Garcia Cid, km 38, 086051-990 Londrina (Brazil); Vieira, Jose M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN-SP, Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-900 Sao Paulo (Brazil); Hamada, Margarida M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN-SP, Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-900 Sao Paulo (Brazil)], E-mail: mmhamada@ipen.br

    2010-04-15

    A 1 cm{sup 3} cylindrical ionization chamber was developed to measure high doses on line during the sample irradiation in static position, in a {sup 60}Co industrial plant. The developed ionization chamber showed to be suitable for use as a dosimeter on line. A good linearity of the detector was found between the dose and the accumulated charge, independently of the different dose rates caused by absorbing materials.

  7. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, Georgina [Semmelweis Univ., Budapest (Hungary); Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary)

    2010-07-15

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D{sub min}) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D{sub r}) and urethra (D{sub u}), dose to volume of 2 cm{sup 3} of the rectum (D{sub 2ccm}), and 0.1 cm{sup 3} and 1% of the urethra (D{sub 0.1ccm} and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V{sub p}) was 27.1 cm{sup 3}. The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D{sub min} was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D{sub 2ccm} = 49% for the rectum, D{sub 0.1ccm} = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D{sub r}, D{sub 2ccm}) = 0.69, R(D{sub u}, D{sub 0.1ccm}) = 0.64, R(D{sub u}, D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose

  8. Determinants of Quality of Life in High-Dose Benzodiazepine Misusers

    Directory of Open Access Journals (Sweden)

    Stefano Tamburin

    2017-01-01

    Full Text Available Benzodiazepines (BZDs are among the most widely prescribed drugs in developed countries, but they have a high potential for tolerance, dependence and misuse. High-dose BZD misuse represents an emerging addiction phenomenon, but data on quality of life (QoL in high-dose BZD misusers are scant. This study aimed to explore QoL in high-dose BZD misuse. We recruited 267 high-dose BZD misusers, compared the QoL scores in those who took BZD only to poly-drug misusers, and explored the role of demographic and clinical covariates through multivariable analysis. Our data confirmed worse QoL in high-dose BZD misusers and showed that (a QoL scores were not negatively influenced by the misuse of alcohol or other drugs, or by coexisting psychiatric disorders; (b demographic variables turned out to be the most significant predictors of QoL scores; (c BZD intake significantly and negatively influenced QoL. Physical and psychological dimensions of QoL are significantly lower in high-dose BZD misusers with no significant effect of comorbidities. Our data suggest that the main reason for poor QoL in these patients is high-dose BZD intake per se. QoL should be considered among outcome measures in these patients.

  9. Determinants of Quality of Life in High-Dose Benzodiazepine Misusers

    Science.gov (United States)

    Tamburin, Stefano; Federico, Angela; Faccini, Marco; Casari, Rebecca; Morbioli, Laura; Sartore, Valentina; Mirijello, Antonio; Addolorato, Giovanni; Lugoboni, Fabio

    2017-01-01

    Benzodiazepines (BZDs) are among the most widely prescribed drugs in developed countries, but they have a high potential for tolerance, dependence and misuse. High-dose BZD misuse represents an emerging addiction phenomenon, but data on quality of life (QoL) in high-dose BZD misusers are scant. This study aimed to explore QoL in high-dose BZD misuse. We recruited 267 high-dose BZD misusers, compared the QoL scores in those who took BZD only to poly-drug misusers, and explored the role of demographic and clinical covariates through multivariable analysis. Our data confirmed worse QoL in high-dose BZD misusers and showed that (a) QoL scores were not negatively influenced by the misuse of alcohol or other drugs, or by coexisting psychiatric disorders; (b) demographic variables turned out to be the most significant predictors of QoL scores; (c) BZD intake significantly and negatively influenced QoL. Physical and psychological dimensions of QoL are significantly lower in high-dose BZD misusers with no significant effect of comorbidities. Our data suggest that the main reason for poor QoL in these patients is high-dose BZD intake per se. QoL should be considered among outcome measures in these patients.

  10. Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi

    2016-11-08

    Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.

  11. High-dose gadolinium-enhanced MRI for diagnosis of meningeal metastases

    Energy Technology Data Exchange (ETDEWEB)

    Kallmes, D.F. [Department of Radiology, Box 170, University of Virginia Health Sciences Center, Charlottesville, VA 22908 (United States); Gray, L. [Department of Radiology, Duke University Medical Center, Durham, NC (United States); Glass, J.P. [Department of Medicine, Veterans Administration Hospital, Gainesville, Florida (United States)

    1998-01-01

    We compared high-dose (0.3 mmol/kg) and standard-dose (0.1 mmol/kg) gadolinium-enhanced MRI for diagnosis of meningeal metastases in 12 patients with suspected meningeal metastases. They were imaged with both standard-dose and high-dose gadolinium. All patients with abnormal meningeal enhancement underwent at least one lumbar puncture for cerebrospinal fluid (CSF) cytology, while patients with normal meningeal enhancement were followed clinically. All patients with negative CSF cytology also were followed clinically. A single observer reviewed all the images, with specific attention to the enhancement pattern of the meninges. Abnormal leptomeningeal enhancement was present in three cases, and abnormal pachymeningeal enhancement in three other patients. All of these patients had abnormal CSF analyses. In two of the three cases of abnormal leptomeningeal enhancement the disease was more evident on high-dose than on standard-dose imaging; in one case the abnormal enhancement was visible only on high-dose imaging. In one of the three cases with abnormal pachymeningeal enhancement, the disease was evident prospectively only with high-dose imaging. (orig.) With 3 figs., 10 refs.

  12. A comparative analysis of radiobiological models for cell surviving fractions at high doses.

    Science.gov (United States)

    Andisheh, B; Edgren, M; Belkić, Dž; Mavroidis, P; Brahme, A; Lind, B K

    2013-04-01

    For many years the linear-quadratic (LQ) model has been widely used to describe the effects of total dose and dose per fraction at low-to-intermediate doses in conventional fractionated radiotherapy. Recent advances in stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) have increased the interest in finding a reliable cell survival model, which will be accurate at high doses, as well. Different models have been proposed for improving descriptions of high dose survival responses, such as the Universal Survival Curve (USC), the Kavanagh-Newman (KN) and several generalizations of the LQ model, e.g. the Linear-Quadratic-Linear (LQL) model and the Pade Linear Quadratic (PLQ) model. The purpose of the present study is to compare a number of models in order to find the best option(s) which could successfully be used as a fractionation correction method in SRT. In this work, six independent experimental data sets were used: CHOAA8 (Chinese hamster fibroblast), H460 (non-small cell lung cancer, NSLC), NCI-H841 (small cell lung cancer, SCLC), CP3 and DU145 (human prostate carcinoma cell lines) and U1690 (SCLC). By detailed comparisons with these measurements, the performance of nine different radiobiological models was examined for the entire dose range, including high doses beyond the shoulder of the survival curves. Using the computed and measured cell surviving fractions, comparison of the goodness-of-fit for all the models was performed by means of the reduced χ (2)-test with a 95% confidence interval. The obtained results indicate that models with dose-independent final slopes and extrapolation numbers generally represent better choices for SRT. This is especially important at high doses where the final slope and extrapolation numbers are presently found to play a major role. The PLQ, USC and LQL models have the least number of shortcomings at all doses. The extrapolation numbers and final slopes of these models do not depend on dose. Their asymptotes

  13. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    Science.gov (United States)

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (agedphenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  14. A new model of biodosimetry to integrate low and high doses.

    Directory of Open Access Journals (Sweden)

    Mònica Pujol

    Full Text Available Biological dosimetry, that is the estimation of the dose of an exposure to ionizing radiation by a biological parameter, is a very important tool in cases of radiation accidents. The score of dicentric chromosomes, considered to be the most accurate method for biological dosimetry, for low LET radiation and up to 5 Gy, fits very well to a linear-quadratic model of dose-effect curve assuming the Poisson distribution. The accuracy of this estimation raises difficulties for doses over 5 Gy, the highest dose of the majority of dose-effect curves used in biological dosimetry. At doses over 5 Gy most cells show difficulties in reaching mitosis and cannot be used to score dicentric chromosomes. In the present study with the treatment of lymphocyte cultures with caffeine and the standardization of the culture time, metaphases for doses up to 25 Gy have been analyzed. Here we present a new model for biological dosimetry, which includes a Gompertz-type function as the dose response, and also takes into account the underdispersion of aberration-among-cell distribution. The new model allows the estimation of doses of exposures to ionizing radiation of up to 25 Gy. Moreover, the model is more effective in estimating whole and partial body exposures than the classical method based on linear and linear-quadratic functions, suggesting their effectiveness and great potential to be used after high dose exposures of radiation.

  15. A New Model of Biodosimetry to Integrate Low and High Doses

    Science.gov (United States)

    Pujol, Mònica; Barquinero, Joan-Francesc; Puig, Pedro; Puig, Roser; Caballín, María Rosa; Barrios, Leonardo

    2014-01-01

    Biological dosimetry, that is the estimation of the dose of an exposure to ionizing radiation by a biological parameter, is a very important tool in cases of radiation accidents. The score of dicentric chromosomes, considered to be the most accurate method for biological dosimetry, for low LET radiation and up to 5 Gy, fits very well to a linear-quadratic model of dose-effect curve assuming the Poisson distribution. The accuracy of this estimation raises difficulties for doses over 5 Gy, the highest dose of the majority of dose-effect curves used in biological dosimetry. At doses over 5 Gy most cells show difficulties in reaching mitosis and cannot be used to score dicentric chromosomes. In the present study with the treatment of lymphocyte cultures with caffeine and the standardization of the culture time, metaphases for doses up to 25 Gy have been analyzed. Here we present a new model for biological dosimetry, which includes a Gompertz-type function as the dose response, and also takes into account the underdispersion of aberration-among-cell distribution. The new model allows the estimation of doses of exposures to ionizing radiation of up to 25 Gy. Moreover, the model is more effective in estimating whole and partial body exposures than the classical method based on linear and linear-quadratic functions, suggesting their effectiveness and great potential to be used after high dose exposures of radiation. PMID:25461738

  16. Variation in long-term antipsychotic polypharmacy and high-dose prescribing across physicians and hospitals.

    Science.gov (United States)

    Latimer, Eric A; Naidu, Adonia; Moodie, Erica E M; Clark, Robin E; Malla, Ashok K; Tamblyn, Robyn; Wynant, Willy

    2014-10-01

    This study had two aims: to measure the prevalence of long-term prescribing of high doses of antipsychotics and antipsychotic polypharmacy in a large Canadian province and to estimate the relative contributions of patient-, physician-, and hospital-level factors. Government hospital discharge, physician, and pharmaceutical claims data were linked to identify individuals with schizophrenia who in 2004 had antipsychotics available to them for at least 11 months. Individuals on a high dose throughout that period, as well as individuals on multiple concurrent antipsychotics (polypharmacy), were identified. Logistic and generalized linear mixed models using patient-, physician-, and hospital-level predictors were estimated. Among the 12,150 individuals identified, 11.9% were on a high dose and 10.4% on antipsychotic polypharmacy continually, with 3.7% in both groups. After adjustment for potential confounders, analyses showed that systematic propensity for physicians to prescribe high doses accounted for 10.9% of the remaining unexplained variance, and physicians as a group who prescribed high doses across a hospital or psychiatry department accounted for 3.0%. For antipsychotic polypharmacy the corresponding percentages were 9.7% and 6.2%. Even after adjustment, the variation in high-dose prescribing and antipsychotic polypharmacy remained substantial. Long-term high-dose and antipsychotic polypharmacy prescribing appeared partly driven by some physicians' and some hospitals' propensities to prescribe in this way independently of patient characteristics. Given the weight of the evidence against high-dose prescribing and antipsychotic polypharmacy, measures addressed to physicians and hospitals most likely to prescribe high doses, antipsychotic polypharmacy, or both should be considered.

  17. Maternal high-dose folic acid during pregnancy and asthma medication in the offspring

    NARCIS (Netherlands)

    Zetstra-van der Woude, Priscilla A.; De Walle, Hermien E. K.; Hoek, Annemieke; Bos, H. Jens; Boezen, H. Marike; Koppelman, Gerhard H.; de Jong-van den Berg, Lolkje T. W.; Scholtens, Salome

    2014-01-01

    Purpose Low-dose folic acid supplementation (0.5 mg) taken during pregnancy has been associated with an increased risk for childhood asthma. The effect of high-dose folic acid (5 mg) advised to women at risk for having a child with neural tube defect has not been assessed so far. Our aim was to inve

  18. Extra-high doses detected in the enamel of human teeth in the Techa riverside region

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A., E-mail: ElenaA.Shishkina@gmail.com [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Degteva, M.O.; Tolstykh, E.I.; Volchkova, A. [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Ivanov, D.V. [Institute of Metal Physics, Russian Academy of Sciences, 18 S. Kovalevsky Str, 620041 Yekaterinburg (Russian Federation); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, D-85764 Neuherberg (Germany); Della Monaca, S. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Regina Elena, 00144 Rome (Italy); Fattibene, P. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Nazionale di Fisica Nucleare, 00161 Rome (Italy)

    2011-09-15

    During the long-term study of tooth enamel by EPR dosimetry for population exposed to radiation due to contamination of the Techa River, it was found out that for some of the tooth donors the dose accumulated in tooth enamel could be as high as several tens of Gy. Such doses were absorbed only in tooth enamel and they should not be associated with exposures to other organs or the whole body. The nature of such doses was discussed in a number of previous papers where it was shown that the source of such doses is {sup 90}Sr incorporated in the calcified dental tissues. However, among specialists in radiation dosimetry who were not involved in the biokinetic studies, the nature and dosimetric significance of extra-high doses in tooth enamel are still raising questions. The aim of the current paper is to summarize the accumulated information on extra-high doses in the teeth of the Techa riverside residents, describe the dose levels observed, explain the nature of extra-high doses in the enamel and discuss their informative value. The paper includes an overview of already published findings and an analysis of information collected in the data bank of the Urals Research Center for Radiation Medicine (URCRM), Chelyabinsk, Russia, which has not been published before.

  19. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy. Addendum

    Science.gov (United States)

    2009-06-01

    compromising the dose coverage of the prostate and the protection to the urethra , rectum, and bladder for prostate cancer patients treated with High...fusion, dose escalation, prostate cancer 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF...18 4 INTRODUCTION Research Project Description Men with prostate cancer , in particular those with advanced

  20. Comparative Effectiveness of High-Dose Versus Standard-Dose Influenza Vaccines Among US Medicare Beneficiaries in Preventing Postinfluenza Deaths During 2012-2013 and 2013-2014.

    Science.gov (United States)

    Shay, David K; Chillarige, Yoganand; Kelman, Jeffrey; Forshee, Richard A; Foppa, Ivo M; Wernecke, Michael; Lu, Yun; Ferdinands, Jill M; Iyengar, Arjun; Fry, Alicia M; Worrall, Chris; Izurieta, Hector S

    2017-02-15

    Recipients of high-dose vs standard-dose influenza vaccines have fewer influenza illnesses. We evaluated the comparative effectiveness of high-dose vaccine in preventing postinfluenza deaths during 2012-2013 and 2013-2014, when influenza viruses and vaccines were similar. We identified Medicare beneficiaries aged ≥65 years who received high-dose or standard-dose vaccines in community-located pharmacies offering both vaccines. The primary outcome was death in the 30 days following an inpatient or emergency department encounter listing an influenza International of Classification of Diseases, Ninth Revision, Clinical Modification code. Effectiveness was estimated by using multivariate Poisson regression models; effectiveness was allowed to vary by season. We studied 1039645 recipients of high-dose and 1683264 recipients of standard-dose vaccines during 2012-2013, and 1508176 high-dose and 1877327 standard-dose recipients during 2013-2014. Vaccinees were well-balanced for medical conditions and indicators of frail health. Rates of postinfluenza death were 0.028 and 0.038/10000 person-weeks in high-dose and standard-dose recipients, respectively. Comparative effectiveness was 24.0% (95% confidence interval [CI], .6%-42%); there was evidence of variation by season (P = .12). In 2012-2013, high-dose was 36.4% (95% CI, 9.0%-56%) more effective in reducing mortality; in 2013-2014, it was 2.5% (95% CI, -47% to 35%). High-dose vaccine was significantly more effective in preventing postinfluenza deaths in 2012-2013, when A(H3N2) circulation was common, but not in 2013-2014.

  1. Chronic low-dose radiation protects cells from high-dose radiation via increase of AKT expression by NF-{sub k}B

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyung Sun; Seong, Ki Moon; Kim, Ji Young; Kim, Cha Soon; Yang, Kwang Hee; Nam, Seon Young [Radiation Effect Research Team, Radiation Health Research Institute, Korea Hydro and Nuclear Power Co., LTD., Gyeongju (Korea, Republic of)

    2013-04-15

    Exposure to low-dose and low-dose rate of ionizing radiation is an important issue in radiation protection. Low-dose ionizing radiation has been observed to elicit distinctly different responses compared to high-dose radiation, in various biological systems including the reproductive, immune, and hematopoietic systems (Liu et al. 2006). Some data were reported that low-dose radiation could initiate beneficial effects by stimulating cell growth, DNA repair, activation of transcription factors and gene expression (Calabrese et al., 2004). Cells exposed to low-dose radiation can develop adaptive resistance to subsequent high-dose radiation induced DNA damage, gene mutation, and cell death. We previously reported that low-dose of ionizing radiation induced cell survival through the activation of AKT (protein kinase B, PKB) pathway (Park et al., 2009). AKT has been shown to be potently activated in response to a wide variety of growth factors and ionizing radiation. Cell survival against ionizing radiation seems to be associated with the activation of AKT pathway via phosphorylation of its downstream nuclear target molecules. In the present study, we examined the effects of chronic low-dose irradiation in human lung fibroblast cells. The aim was to explore the possibility of a low-dose radiation-induced adaptive cellular response against subsequent challenging high-dose irradiation. In the present study, we examined the regulatory mechanism responsible for cellular response induced by chronic low-dose of ionizing radiation in normal human cells. We found that the level of AKT protein was closely associated with cell survival. In addition, NF-{sub k}B activation by chronic low-dose radiation regulates AKT activation via gene expression and acinus expression. In conclusion, our data demonstrate that chronic low-dose radiation could inhibit the cell death induced by cytotoxic high-dose radiation through the modulation of the level of AKT and acinus proteins via NF-{sub k

  2. Prospective study of long-term impact of adjuvant high-dose and conventional-dose chemotherapy on health-related quality of life

    NARCIS (Netherlands)

    Buijs, C.; Rodenhuis, S.; Seynaeve, C.M.; van Hoesel, Q.G.; van der Wall, E.; Smit, W.J.; Nooij, M.A.; Voest, E.; Hupperets, P.; TenVergert, E.M.; van Tinteren, H.; Willemse, P.H.; Mourits, M.J.; Aaronson, N.K.; Post, W.J.; de Vries, E.G.

    2007-01-01

    Purpose To evaluate and compare health-related quality of life (HRQOL) after conventional- and high-dose adjuvant chemotherapy in patients with high-risk breast cancer. Patients and Methods Patients were randomly assigned to either a conventional or high-dose chemotherapy regimen; both regimens were

  3. An ultra-high dose of electron radiation response of Germanium Flat Fiber and TLD-100

    Science.gov (United States)

    Alawiah, A.; Amin, Y. M.; Abdul-Rashid, H. A.; Abdullah, W. S. Wan; Maah, M. J.; Bradley, D. A.

    2017-01-01

    The thermoluminescence (TL) response of Germanium Flat Fiber (GFF) and TLD-100 irradiated with 2.5 MeV electrons for the doses up to 1 MGy were studied and compared. The aim was to evaluate the TL supralinearity response at an ultra-high dose (UHD) range and to investigate the change in kinetic parameters of the glow peaks, as the doses increases up to 1 MGy. It is found that the critical dose limit (CDL) of GFF is 5 times higher as compared to TLD-100. CDL is determined by the dose at the maximum supralinearity, f(D)max. It is also found that annealing the TLD-100 and GFF with temperature more than 400 °C is required to reset it back to its original condition, following radiation doses up to 1 MGy. It is also noticed the strange behavior of Peak 4 (TLD-100), which tends to be invisible at the lower dose (<10 kGy) and starts to be appeared at the critical dose limit of 10 kGy. This result might be an important clue to understand the behavior of TLD-100 at extremely high dose range. For both samples, it is observed that the TL intensity is not saturated within the UHD range studied.

  4. Donut-shaped high-dose configuration for proton beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Rutz, H.P.; Lomax, A.J. [Div. of Radiation Medicine, Paul Scherrer Inst., Villigen PSI (Switzerland)

    2005-01-01

    Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is also applicable to spare other critical structures passing through a target volume, including spinal cord, optic nerves, chiasm, brain stem, or urethra. (orig.)

  5. A case of percutaneous high dose rate brachytherapy for superior pulmonary sulcus tumor

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, Tamaki; Imamura, Masahiro; Murata, Takashi [Kansai Medical Univ., Moriguchi, Osaka (Japan)] [and others

    1996-07-01

    A 64-year-old man with advanced superior pulmonary sulcus tumor suffered severe unrelieved pain even after chemotherapy, external irradiation and hyperthermia. So we planned to introduce a percutaneous high dose rate brachytherapy using the microselectron HDR {sup 192}Ir. With the estimation using the Pain Score, satisfying pain relief was attainable with a combination of the percutaneous high dose rate brachytherapy and conventional treatment. So the percutaneous high dose rate brachytherapy had the possibility to contribute to the alleviation of the pain. (author)

  6. "Half-half" blisters in bullous pemphigoid successfully treated with adjuvant high-dose intravenous immunoglobulin.

    Science.gov (United States)

    Pacheco, David; Lopes, Leonor; Soares-Almeida, Luis; Marques, Manuel Sacramento; Filipe, Paulo

    2012-09-01

    Bullous pemphigoid is a rare, autoimmune blistering disease. Its clinical presentation is tense blisters that may arise on normal-appearing or erythematous skin. Bullous pemphigoid refractory to systemic corticosteroids in combination with immunosuppressants such as azathioprine and mycophenolate mofetil may benefit from adjuvant high-dose intravenous immunoglobulin (IVIg). We describe a particular case with an unusual clinical presentation unresponsive to systemic corticosteroids plus azathioprine, in which the addition of high-dose IVIg was successful. The combined therapy of systemic corticosteroids and azathioprine plus high-dose IVIg can be an option in refractory cases due to its efficiency and tolerability.

  7. Regular self-microstructuring on CR39 using high UV laser dose

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, P., E-mail: parvin@aut.ac.ir [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran (Iran, Islamic Republic of); Refahizadeh, M. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran (Iran, Islamic Republic of); Mortazavi, S.Z. [Physics Department, Faculty of Science, Imam Khomeini International University, P.O. Box 34149-16818, Qazvin (Iran, Islamic Republic of); Silakhori, K. [Laser and Optics Research School, P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of); Mahdiloo, A. [Mining and Metallurgical Engineering Department, Amirkabir University of Technology, P.O. Box 1591634311, Tehran (Iran, Islamic Republic of); Aghaii, P. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran (Iran, Islamic Republic of)

    2014-02-15

    The UV laser induced replicas in the form of self-lining microstructures are created by high dose (with high fluence) ArF laser irradiation on CR39. Microstructures as the self-induced contours, in the form of concentric circles, appear when the laser fluence is well above the ablation threshold. It leads to the regular periodic parallel lines, i.e. circles with large radii having spatial separation 100–200 nm and line width 300–600 nm, where the number of shots increases to achieve higher UV doses. The surface wettability is also investigated after laser texturing to exhibit that a notable hydrophilicity takes place at high doses.

  8. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  9. Measurement of the Space Radiation Dose for the Flight Aircrew at High-Altitude

    Science.gov (United States)

    Lee, Jaewon; Park, Inchun; Kim, Junsik; Lee, Jaejin; Hwang, Junga; Kim, Young-chul

    2014-03-01

    This paper describes an experimental approach to evaluate the effective doses of space radiations at high-altitude by combining the measured data from the Liulin-6K spectrometer loaded onto the air-borne RC-800 cockpit and the calculated data from CARI-6M code developed by FAA. In this paper, 15 exposed dose experiments for the flight missions at a highaltitude above 10 km and 3 experiments at a normal altitude below 4 km were executed over the Korean Peninsula in 2012. The results from the high-altitude flight measurements show a dramatic change in the exposed doses as the altitude increases. The effective dose levels (an average of 15.27 mSv) of aircrew at the high-altitude are an order of magnitude larger than those (an average of 0.30 mSv) of the normal altitude flight. The comparison was made between the measure dose levels and the calculated dose levels and those were similar each other. It indicates that the annual dose levels of the aircrew boarding RC- 800 could be above 1 mSv. These results suggest that a proper procedure to manage the exposed dose of aircrew is required for ROK Air Force.

  10. The effects of high dose and highly fractionated radiation on distraction osteogenesis in the murine mandible.

    Science.gov (United States)

    Monson, Laura A; Cavaliere, Christi M; Deshpande, Sagar S; Ayzengart, Alexander L; Buchman, Steven R

    2012-09-07

    The ability of irradiated tissue to support bony growth remains poorly defined, although there are anecdotal cases reported showing mixed results for the use of mandibular distraction osteogenesis after radiation for head and neck cancer. Many of these reports lack objective measures that would allow adequate analysis of outcomes or efficacy. The purpose of this experiment was to utilize a rat model of mandibular distraction osteogenesis after high dose and highly fractionated radiation therapy and to evaluate and quantify distracted bone formation under these conditions. Male Sprague-Dawley rats underwent 12 fractions of external beam radiation (48 Gray) of the left mandible. Following a two week recovery period, an external frame distractor was applied and gradual distraction of the mandible was performed. Tissue was harvested after a twenty-eight day consolidation period. Gross, radiologic and histological evaluations were undertaken. Those animals subjected to pre-operative radiation showed severe attenuation of bone formation including bone atrophy, incomplete bridging of the distraction gap, and gross bony defects or non-union. Although physical lengthening was achieved, the irradiated bone consistently demonstrated marked damaging effects on the normal process of distraction osteogenesis. This murine model has provided reliable evidence of the injurious effects of high dose radiation on bone repair and regeneration in distraction osteogenesis utilizing accurate and reproducible metrics. These results can now be used to assist in the development of therapies directed at mitigating the adverse consequences of radiation on the regeneration of bone and to optimize distraction osteogenesis so it can be successfully applied to post-oncologic reconstruction.

  11. High-order noise analysis for low dose iterative image reconstruction methods: ASIR, IRIS, and MBAI

    Science.gov (United States)

    Do, Synho; Singh, Sarabjeet; Kalra, Mannudeep K.; Karl, W. Clem; Brady, Thomas J.; Pien, Homer

    2011-03-01

    Iterative reconstruction techniques (IRTs) has been shown to suppress noise significantly in low dose CT imaging. However, medical doctors hesitate to accept this new technology because visual impression of IRT images are different from full-dose filtered back-projection (FBP) images. Most common noise measurements such as the mean and standard deviation of homogeneous region in the image that do not provide sufficient characterization of noise statistics when probability density function becomes non-Gaussian. In this study, we measure L-moments of intensity values of images acquired at 10% of normal dose and reconstructed by IRT methods of two state-of-art clinical scanners (i.e., GE HDCT and Siemens DSCT flash) by keeping dosage level identical to each other. The high- and low-dose scans (i.e., 10% of high dose) were acquired from each scanner and L-moments of noise patches were calculated for the comparison.

  12. MCz diode response as a high-dose gamma radiation dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, F. [Instituto de Pesquisas Energeticas e Nucleares-IPEN-CNEN/SP, Caixa Postal 11049 - 05422 970 Sao Paulo/SP (Brazil); Goncalves, J.A.C. [Instituto de Pesquisas Energeticas e Nucleares-IPEN-CNEN/SP, Caixa Postal 11049 - 05422 970 Sao Paulo/SP (Brazil); Depto. de Fisica, Pontificia Universidade Catolica de Sao Paulo-PUC/SP, Rua Marques de Paranagua no 111-01303 050 Sao Paulo/SP (Brazil); Khoury, H.J. [Nuclear Energy Department, Universidade Federal de Pernambuco-UFPE, Av. Prof. Luiz Freire no 1000-50740 540 Recife/PE (Brazil); Napolitano, C.M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN-CNEN/SP, Caixa Postal 11049 - 05422 970 Sao Paulo/SP (Brazil); Haerkoenen, J. [Helsinki Institute of Physics-HIP, University of Helsinki, 00014 Helsinki (Finland); Bueno, C.C. [Instituto de Pesquisas Energeticas e Nucleares-IPEN-CNEN/SP, Caixa Postal 11049 - 05422 970 Sao Paulo/SP (Brazil); Depto. de Fisica, Pontificia Universidade Catolica de Sao Paulo-PUC/SP, Rua Marques de Paranagua no 111-01303 050 Sao Paulo/SP (Brazil)], E-mail: ccbueno@ipen.br

    2008-02-15

    This work presents the preliminary results obtained with a high-resistivity magnetic Czochralski (MCz) silicon diode processed at the Helsinki Institute of Physics as a high-dose gamma dosimeter in radiation processing. The irradiation was performed using a {sup 60}Co source (Gammacell 220, MDS Nordion) within total doses from 100 Gy up to 3 kGy at a dose rate of 3 kGy/h. In this interval, the dosimetric response of the diode is linear with a correlation coefficient (r{sup 2}) higher than 0.993. However, without any irradiation procedure, the device showed a small sensitivity dependence on the accumulated dose. For total dose of 3 kGy, the observed decrease was about 2%. To clarify the origin of this possible radiation damage effect, some studies are under way.

  13. High-dose insulin therapy in beta-blocker and calcium channel-blocker poisoning.

    Science.gov (United States)

    Engebretsen, Kristin M; Kaczmarek, Kathleen M; Morgan, Jenifer; Holger, Joel S

    2011-04-01

    INTRODUCTION. High-dose insulin therapy, along with glucose supplementation, has emerged as an effective treatment for severe beta-blocker and calcium channel-blocker poisoning. We review the experimental data and clinical experience that suggests high-dose insulin is superior to conventional therapies for these poisonings. PRESENTATION AND GENERAL MANAGEMENT. Hypotension, bradycardia, decreased systemic vascular resistance (SVR), and cardiogenic shock are characteristic features of beta-blocker and calcium-channel blocker poisoning. Initial treatment is primarily supportive and includes saline fluid resuscitation which is essential to correct vasodilation and low cardiac filling pressures. Conventional therapies such as atropine, glucagon and calcium often fail to improve hemodynamic status in severely poisoned patients. Catecholamines can increase blood pressure and heart rate, but they also increase SVR which may result in decreases in cardiac output and perfusion of vascular beds. The increased myocardial oxygen demand that results from catecholamines and vasopressors may be deleterious in the setting of hypotension and decreased coronary perfusion. METHODS. The Medline, Embase, Toxnet, and Google Scholar databases were searched for the years 1975-2010 using the terms: high-dose insulin, hyperinsulinemia-euglycemia, beta-blocker, calcium-channel blocker, toxicology, poisoning, antidote, toxin-induced cardiovascular shock, and overdose. In addition, a manual search of the Abstracts of the North American Congress of Clinical Toxicology and the Congress of the European Association of Poisons Centres and Clinical Toxicologists published in Clinical Toxicology for the years 1996-2010 was undertaken. These searches identified 485 articles of which 72 were considered relevant. MECHANISMS OF HIGH-DOSE INSULIN BENEFIT. There are three main mechanisms of benefit: increased inotropy, increased intracellular glucose transport, and vascular dilatation. EFFICACY OF HIGH-DOSE

  14. HIGH AND LOW DOSE IVIG THERAPY IN GUILLAIN-BARRE SYNDROME CHILDREN: A COMPARISON

    Directory of Open Access Journals (Sweden)

    P. KARIMZADEH MD

    2009-05-01

    Full Text Available Objective:Acute inflammatory demyelinating peripheral neuropathy (Guillain-Barre-Syndrome is by far the most common cause of immune-medicated peripheral nervous system disease in children; with the near disappearance of poliomyelitis, GBS is responsible for the great majority of cases of acute flaccid paralysis. So far, in several controlled studies, corticosteroids, plasmapheresis and IVIG have been utilized in pediatric patients, afflicted with GBS. Regarding IVIG therapy, two methods have been used; the high dose (1 gr/kg/day for 2 days, and the low dose (400mg/kg/day for 5 days. Review of literature shows that a faster rate of recovery can be accomplished in patients who receive total dose of IVIG in 2 days as compared to the dose being given over 5 days.Materials & Methods:In this study we have compared these two types of treatment in an investigation, conducted in the Mofid Children Hospital on pediatric patients who had sudden onset of acute flaccid  paralysis, and were diagnosed as having GBS. Based on histories, physical examination and electrodiagnosis, subjects were divided in two groups, the high dose IVIG treatment, 1gr/kg/day for 2 days (experimental group, and the low dose IVIG treatment, 400 mg/kg/day for 5 days (control group. Statistical analyses were then carried out using the appropriate software.Results:Result of this study showed a faster rate of recovery for patients in the high dose IVIG group; in this group duration of weakness of limbs was shorter and returning of DTR was faster than in controls. In fact, in this type of treatment, the relationship between high dose IVIG therapy and drug side effects was not significant.Conclusion:Base upon the finding in the present study, we conclude that the high dose IVIG therapy is superior to low dose, in view of faster duration of recovery and shorter hospital stay. Also we may infer that shorter hospital stay could be a factor in reducing of more nasocomial infection. In

  15. High dose rate endobronchial brachytherapy: a curative treatment; La curietherapie endobronchique de haut debit de dose: un traitement curatif

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Spaeth, D.; Winnefeld, J. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Menard, O. [Centre Hospitalier Universitaire Nancy-Brabois, 54 - Vandoeuvre-les-Nancy (France)

    2000-06-01

    New endobronchial techniques of treatment allow a good unblocking. Nevertheless, only high dose rate brachytherapy delivers a curative treatment for invasive carcinomas. This study analyses the results of the first 33 consecutive patients treated with curative intent by this technique from 1994 to 1997, and followed-up more than one year. Thirty-seven lesions were treated, with usual schedule delivering 30 Gy at 1 cm depth in six fractions and three to five weeks. All the patients were meticulously selected on the local involvement of the tumour and absolute contraindications to a surgical treatment. All of them have a pulmonary disease history or a general contraindication. With a 14-month follow-up, the local control at two months after the treatment was 95 % (endoscopic and histologic), and 90 % of the patients presented a prolonged local control. Four patients died of the treated cancer, another of a controlateral cancer. Ten patients died of another disease, five of them from a respiratory insufficiency. The overall survival rate at two years was 53 % and the specific survival rate 80 %. The acute tolerance was good, without incident. Asymptomatic bronchial stenoses, described by endoscopic follow-up, were described for seven patients. We conclude that, on the basis of a good selection of the patients, and a respect of the indications, high dose rate endobronchial brachytherapy is an effective curative treatment. It offers a new curative option and must be proposed for the small invasive carcinomas in non-operable patients. (author)

  16. "EFFECT OF HIGH VERSUS LOW DOSES OF HUMAN RECOMBINANT ERYTHROPOIETIN ON THE ANEMIA OF PREMATURITY"

    Directory of Open Access Journals (Sweden)

    A. Mohammadzadeh

    2005-05-01

    Full Text Available Recombinant human erythropoietin (rh-EPO is known to accelerate erythropoiesis in preterm infants. The purpose of this study was to compare the effectiveness of early treatment with two doses of rh-EPO (high vs. low dose in the management of anemia of prematurity. Twenty preterm infants with hematocrit (Hct < 30% when infant’s age was between 2 to 3 weeks after birth or Hct <25% when infant’s age was more than 3 weeks after birth, were divided randomly in two groups, each group including 10 babies. Infants in high dose group received 500 u/kg rh-EPO twice per week and the low dose group received 500 u/kg rh-EPO weekly. All infants were fed human milk supplemented with enteral iron. Hematocrit and reticulocyte counts were determined for each infant at the start of the study, 3 days after start of treatment and one week after the end of treatment. The means of gestational age in high dose and low dose groups were 31.4 ± 2.2 and 31.3±2.0 weeks, respectively. Means of birth weight in high dose and low dose groups were 1366 ± 243 and 1438±249 gr, respectively. The two groups were significantly different in reticulocyte count at 3 days after treatment (P = 0.047 and in hematocrit at the end of study (P < 0.0001. We concluded the early treatment of anemia of prematurity with high dose rh-EPO with supplemental iron significantly increases hematocrit and reticulocyte in preterm infants and reduce the need for blood transfusion in these high risk neonates.

  17. High-dose dosimetry of beta rays using blue beryl dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do, E-mail: lsatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Bittencour, Jose F., E-mail: Lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear

    2015-07-01

    High dose radiation is widely used in industrial applications as sterilization of medical products, improvement of materials properties, color enhancement of jewelry stones, etc. The radiation dosimetry of high doses is quite important for these applications. In this work we have investigated the usage of blue beryl crystal also known as aquamarine in high dose dosimetry of beta rays. Some works have shown that silicate minerals exhibit a good Thermoluminescent response when irradiated up to 2000 kGy of gamma rays. Here, we have produced small beryl pellets of approximately 5 mm in diameter and 3 mm thickness to measure high doses of beta rays produced at an electron accelerator at IPEN. Twelve beryl dosimeters were made and six of them were irradiated from 10kGy up to 100 kGy. The technique used to create a calibration curve was the thermoluminescence using the glow peak at 310°C. (author)

  18. Anti-Inflammatory Properties of Low and High Doxycycline Doses: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Roberta Di Caprio

    2015-01-01

    Full Text Available Doxycycline is used to treat infective diseases because of its broadspectrum efficacy. High dose administration (100 or 200 mg/day is often responsible for development of bacterial resistances and endogenous flora alterations, whereas low doses (20–40 mg/day do not alter bacteria susceptibility to antibiotics and exert anti-inflammatory activities. In this study, we wanted to assess the efficacy of both low and high doxycycline doses in modulating IL-8, TNF-α, and IL-6 gene expression in HaCaT cells stimulated with LPS. Three experimental settings were used, differing in the timing of doxycycline treatment in respect to the insult induced by LPS: pretreatment, concomitant, and posttreatment. Low doses were more effective than high doses in modulating gene expression of LPS-induced proinflammatory cytokines (IL-8, TNF-α, and IL-6, when added before (pretreatment or after (posttreatment LPS stimulation. This effect was not appreciated when LPS and doxycycline were simultaneously added to cell cultures: in this case high doses were more effective. In conclusion, our in vitro study suggests that low doxycycline doses could be safely used in chronic or acute skin diseases in which the inflammatory process, either constantly in progress or periodically recurring, has to be prevented or controlled.

  19. Anti-Inflammatory Properties of Low and High Doxycycline Doses: An In Vitro Study

    Science.gov (United States)

    Di Caprio, Roberta; Di Costanzo, Luisa; Monfrecola, Giuseppe

    2015-01-01

    Doxycycline is used to treat infective diseases because of its broadspectrum efficacy. High dose administration (100 or 200 mg/day) is often responsible for development of bacterial resistances and endogenous flora alterations, whereas low doses (20–40 mg/day) do not alter bacteria susceptibility to antibiotics and exert anti-inflammatory activities. In this study, we wanted to assess the efficacy of both low and high doxycycline doses in modulating IL-8, TNF-α, and IL-6 gene expression in HaCaT cells stimulated with LPS. Three experimental settings were used, differing in the timing of doxycycline treatment in respect to the insult induced by LPS: pretreatment, concomitant, and posttreatment. Low doses were more effective than high doses in modulating gene expression of LPS-induced proinflammatory cytokines (IL-8, TNF-α, and IL-6), when added before (pretreatment) or after (posttreatment) LPS stimulation. This effect was not appreciated when LPS and doxycycline were simultaneously added to cell cultures: in this case high doses were more effective. In conclusion, our in vitro study suggests that low doxycycline doses could be safely used in chronic or acute skin diseases in which the inflammatory process, either constantly in progress or periodically recurring, has to be prevented or controlled. PMID:25977597

  20. [High-dose chemotherapy as a strategy to overcome drug resistance in solid tumors].

    Science.gov (United States)

    Selle, Frédéric; Gligorov, Joseph; Soares, Daniele G; Lotz, Jean-Pierre

    2016-10-01

    The concept of high-doses chemotherapy was developed in the 1980s based on in vitro scientific observations. Exposure of tumor cells to increasing concentrations of alkylating agents resulted in increased cell death in a strong dose-response manner. Moreover, the acquired resistance of tumor cells could be overcome by dose intensification. In clinic, dose intensification of alkylating agents resulted in increased therapeutic responses, however associated with significant hematological toxicity. Following the development of autologous stem cells transplantation harvesting from peripheral blood, the high-doses of chemotherapy, initially associated with marked toxic effects, could be more easily tolerated. As a result, the approach was evaluated in different types of solid tumors, including breast, ovarian and germ cell tumors, small cell lung carcinoma, soft tissue sarcomas and Ewing sarcoma. To date, high-doses chemotherapy with hematopoietic stem cells support is only used as a salvage therapy to treat poor prognosis germ cell tumors patients with chemo-sensitive disease. Regarding breast and ovarian cancer, high-doses chemotherapy should be considered only in the context of clinical trials. However, intensive therapy as an approach to overcome resistance to standard treatments is still relevant. Numerous efforts are still ongoing to identify novel therapeutic combinations and active treatments to improve patients' responses.

  1. Measurement of photoneutron dose produced by wedge filters of a high energy linac using polycarbonate films.

    Science.gov (United States)

    Hashemi, Seyed Mehdi; Hashemi-Malayeri, Bijan; Raisali, Gholamreza; Shokrani, Parvaneh; Sharafi, Ali Akbar; Torkzadeh, Falamarz

    2008-05-01

    Radiotherapy represents the most widely spread technique to control and treat cancer. To increase the treatment efficiency, high energy linacs are used. However, applying high energy photon beams leads to a non-negligible dose of neutrons contaminating therapeutic beams. In addition, using conventional linacs necessitates applying wedge filters in some clinical conditions. However, there is not enough information on the effect of these filters on the photoneutrons produced. The aim of this study was to investigate the change of photoneutron dose equivalent due to the use of linac wedge filters. A high energy (18 MV) linear accelerator (Elekta SL 75/25) was studied. Polycarbonate films were used to measure the dose equivalent of photoneutrons. After electrochemical etching of the films, the neutron dose equivalent was calculated using Hp(10) factor, and its variation on the patient plane at 0, 5, 10, 50 and 100 cm from the center of the X-ray beam was determined. By increasing the distance from the center of the X-ray beam towards the periphery, the photoneutron dose equivalent decreased rapidly for the open and wedged fields. Increasing of the field size increased the photoneutron dose equivalent. The use of wedge filter increased the proportion of the neutron dose equivalent. The increase can be accounted for by the selective absorption of the high energy photons by the wedge filter.

  2. High-Dose and High-Frequency Lanreotide Autogel in Acromegaly: A Randomized, Multicenter Study.

    Science.gov (United States)

    Giustina, Andrea; Mazziotti, Gherardo; Cannavò, Salvatore; Castello, Roberto; Arnaldi, Giorgio; Bugari, Giovanna; Cozzi, Renato; Ferone, Diego; Formenti, Anna Maria; Gatti, Enza; Grottoli, Silvia; Maffei, Pietro; Maffezzoni, Filippo; Montini, Marcella; Terzolo, Massimo; Ghigo, Ezio

    2017-07-01

    Increase in drug frequency or dose is recommended for acromegaly patients with partial response to long-acting somatostatin receptor ligands (SRLs). However, the efficacy and safety data with lanreotide (LAN) Autogel (LAN-ATG) at high dose (HD) or high frequency (HF) are still scanty. To evaluate the biochemical efficacy and safety of HF and HD LAN-ATG in patients with active acromegaly. Twenty-four-week prospective, multicenter, randomized, open-label trial. Thirty patients with active acromegaly, partial responders to SRLs, were randomized to HF (120 mg/21 days; 15 patients) or HD (180 mg/28 days; 15 patients) LAN-ATG. Normalization of serum insulin-like growth factor-I (IGF-I) and reduction in random growth hormone (GH) values < 1.0 µg/L, reduction in serum IGF-I and GH from baseline, differences in biochemical response between HF and HD LAN-ATG, adverse events. IGF-I decreased significantly (P = 0.007) during the 24-week treatment, with greater decrease in HD (P = 0.03) vs HF group (P = 0.08). Normalization in IGF-I values occurred in 27.6% of patients (P = 0.016 vs baseline), without a significant difference between HF and HD groups (P = 0.59). The decrease in serum IGF-I significantly correlated with serum LAN values (P = 0.04), and normalization of IGF-I was predicted by baseline IGF-I values (P = 0.02). Serum GH values did not change significantly (P = 0.22). Overall, 19 patients (63.3%) experienced adverse events, all being mild to moderate and transient, without differences between the two therapeutic arms. HF and HD LAN-ATG regimens are effective in normalizing IGF-I values in about one-third of patients with active acromegaly inadequately controlled by long-term conventional SRLs therapy.

  3. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  4. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer*

    Science.gov (United States)

    Pellizzon, Antônio Cássio Assis

    2016-01-01

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. PMID:27403021

  5. Comparison of high-dose and low-dose insulin by continuous intravenous infusion in the treatment of diabetic ketoacidosis in children.

    Science.gov (United States)

    Burghen, G A; Etteldorf, J N; Fisher, J N; Kitabchi, A Q

    1980-01-01

    We studied the efficacy of low-dose (0.1 U/kg/h) and high-dose (1..0 U/kg/h) insulin, given randomly to children with diabetic ketoacidosis (DKA) by continuous intravenous infusion without a loading dose. Plasma glucose reached 250 mg/dl in 3.4 +/- 0.4 h with the high-dose insulin group compared with 5.4 +/- 0.5 h with the low-dose insulin group (P Hypokalemia (K insulin, with a slower rate of glucose decrease, is as effective as a high dose for the treatment of DKA in children with less incidence of hypokalemia and decreased potential for hypoglycemia.

  6. In-phantom neutron dose distribution for bladder cancer cases treated with high-energy photons

    Science.gov (United States)

    Khaled, N. E.; Attalla, E. M.; Ammar, H.; Khalil, W.

    2011-06-01

    This work presents an estimation of the neutron dose distribution for common bladder cancer cases treated with high-energy photons of 15 MV therapy accelerators. Neutron doses were measured in an Alderson phantom, using TLD 700 and 600 thermoluminescence dosimeters, resembling bladder cancer cases treated with high-energy photons from 15 MV LINAC and having a treatment plan using the four-field pelvic box technique. Thermal neutron dose distribution in the target area and the surrounding tissue was estimated. The sensitivity of all detectors for both gamma and neutrons was estimated and used for correction of the TL reading. TLD detectors were irradiated with a Co60 gamma standard source and thermal neutrons at the irradiation facility of the National Institute for Standards (NIS). The TL to dose conversion factor was estimated in terms of both Co60 neutron equivalent dose and thermal neutron dose. The dose distribution of photo-neutrons throughout each target was estimated and presented in three-dimensional charts and isodose curves. The distribution was found to be non-isotropic through the target. It varied from a minimum of 0.23 mSv/h to a maximum of 2.07 mSv/h at 6 cm off-axis. The mean neutron dose equivalent was found to be 0.63 mSv/h, which agrees with other published literature. The estimated average neutron equivalent to the bladder per administered therapeutic dose was found to be 0.39 mSv Gy-1, which is also in good agreement with published literature. As a consequence of a complete therapeutic treatment of 50 Gy high-energy photons at 15 MV, the total thermal neutron equivalent dose to the abdomen was found to be about 0.012 Sv.

  7. High brachytherapy doses can counteract hypoxia in cervical cancer—a modelling study

    Science.gov (United States)

    Lindblom, Emely; Dasu, Alexandru; Beskow, Catharina; Toma-Dasu, Iuliana

    2017-01-01

    Tumour hypoxia is a well-known adverse factor for the outcome of radiotherapy. For cervical tumours in particular, several studies indicate large variability in tumour oxygenation. However, clinical evidence shows that the management of cervical cancer including brachytherapy leads to high rate of success. It was the purpose of this study to investigate whether the success of brachytherapy for cervical cancer, seemingly regardless of oxygenation status, could be explained by the characteristics of the brachytherapy dose distributions. To this end, a previously used in silico model of tumour oxygenation and radiation response was further developed to simulate the treatment of cervical cancer employing a combination of external beam radiotherapy and intracavitary brachytherapy. Using a clinically-derived brachytherapy dose distribution and assuming a homogeneous dose delivered by external radiotherapy, cell survival was assessed on voxel level by taking into account the variation of sensitivity with oxygenation as well as the effects of repair, repopulation and reoxygenation during treatment. Various scenarios were considered for the conformity of the brachytherapy dose distribution to the hypoxic region in the target. By using the clinically-prescribed brachytherapy dose distribution and varying the total dose delivered with external beam radiotherapy in 25 fractions, the resulting values of the dose for 50% tumour control, D 50, were in agreement with clinically-observed values for high cure rates if fast reoxygenation was assumed. The D 50 was furthermore similar for the different degrees of conformity of the brachytherapy dose distribution to the tumour, regardless of whether the hypoxic fraction was 10%, 25%, or 40%. To achieve 50% control with external RT only, a total dose of more than 70 Gy in 25 fractions would be required for all cases considered. It can thus be concluded that the high doses delivered in brachytherapy can counteract the increased

  8. Elastic stability of high dose neutron irradiated spinel

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z.; Chan, S.K. [Argonne National Lab., Chicago, IL (United States); Garner, F.A. [Pacific Northwest Lab., Richland, WA (United States)] [and others

    1995-04-01

    The objective of this effort is to identify ceramic materials that are suitable for fusion reactor applications. Elastic constants (C{sub 11}, C{sub 12}, and C{sub 44}) of spinel (MgAl{sub 2}O{sub 4}) single crystals irradiated to very high neutron fluences have geen measured by an ultrasonic technique. Although results of a neutron diffraction study show that cation occupation sites are significantly changed in the irradiated samples, no measurable differences occurred in their elastic properties. In order to understand such behavior, the elastic properties of a variety of materials with either normal or inverse spinel structures were studied. The cation valence and cation distribution appear to have little influence on the elastic properties of spinel materials.

  9. High-dose Sulbactam Treatment for Ventilator-Associated Pneumonia Caused by Carbapenem-Resistant

    Directory of Open Access Journals (Sweden)

    In Beom Jeong

    2016-11-01

    Full Text Available Background Several antibiotics can be used to treat ventilator-associated pneumonia caused by carbapenem-resistant A. baumannii (CRAB-VAP including high-dose sulbactam. However, the effectiveness of high-dose sulbactam therapy is not well known. We report our experience with high-dose sulbactam for treatment of CRAB-VAP. Methods Medical records of patients with CRAB-VAP who were given high-dose sulbactam between May 2013 and June 2015 were reviewed. Results Fifty-eight patients with CRAB-VAP were treated with high-dose sulbactam. The mean age was 72.0 ± 15.2 years, and the acute physiology and chronic health evaluation II (APACHE II score was 15.1 ± 5.10 at the time of CRAB-VAP diagnosis. Early clinical improvement was observed in 65.5% of patients, and 30-day mortality was 29.3%. Early clinical failure (odds ratio [OR]: 8.720, confidence interval [CI]: 1.346-56.484; p = 0.023 and APACHE II score ≥ 14 at CRAB-VAP diagnosis (OR: 10.934, CI: 1.047-114.148; p = 0.046 were associated with 30-day mortality. Conclusions High-dose sulbactam therapy may be effective for the treatment of CRAB-VAP. However, early clinical failure was observed in 35% of patients and was associated with poor outcome.

  10. Application of PK/PD modeling and simulation to dosing regimen optimization of high-dose human regular U-500 insulin.

    Science.gov (United States)

    de la Peña, Amparo; Ma, Xiaosu; Reddy, Shobha; Ovalle, Fernando; Bergenstal, Richard M; Jackson, Jeffrey A

    2014-07-01

    Pharmacokinetic/pharmacodynamic (PK/PD) studies of human regular U-500 insulin (U-500R) at high doses commonly used in clinical practice (>100 units) have not been performed. The current analysis applied PK/PD modeling/simulation to fit the data and simulate single-dose and steady-state PK/PD of U-500R high-dose regimens. Data from 3 single-dose euglycemic clamp studies in healthy obese and normal-weight patients, and normal-weight patients with type 1 diabetes were used to build the model. The model was sequential (PK inputs fed into PD component). PK was described using a 1-compartment model with first-order absorption and elimination. The model estimated separate absorption rate constants for U-500R and human regular U-100 insulin. The PD component used an effect compartment model, parameterized in terms of maximum pharmacologic effect (E(max)) and concentration to achieve 50% of E(max). The model described the data well. Steady-state PK for once-daily (QD), twice-daily (BID), or thrice-daily (TID) administration appeared to be reached 24 hours after the first dose. At steady-state, QD dosing showed the greatest fluctuations in PK/PD. BID dosing showed a gradual increase in insulin action with each dose and a fairly stable basal insulin effect. For TID dosing, activity was maintained throughout the dosing interval. PK/PD modeling/simulation of high U-500R doses supports BID or TID administration with an extended duration of activity relative to QD. TID dosing may provide slightly better full-day insulin effect. Additional PK/PD studies and randomized controlled trials of U-500R are needed to validate model predictions in patients with insulin-resistant diabetes requiring high-dose insulin.

  11. High-dose neutron irradiation embrittlement of RAFM steels

    Energy Technology Data Exchange (ETDEWEB)

    Gaganidze, E. [Forschungszentrum Karlsruhe, Institut fuer Materialforschung II, P.O. Box 3640, 76021 Karlsruhe (Germany)]. E-mail: ermile.gaganidze@imf.fzk.de; Schneider, H.-C. [Forschungszentrum Karlsruhe, Institut fuer Materialforschung II, P.O. Box 3640, 76021 Karlsruhe (Germany); Dafferner, B. [Forschungszentrum Karlsruhe, Institut fuer Materialforschung II, P.O. Box 3640, 76021 Karlsruhe (Germany); Aktaa, J. [Forschungszentrum Karlsruhe, Institut fuer Materialforschung II, P.O. Box 3640, 76021 Karlsruhe (Germany)

    2006-09-01

    Neutron irradiation-induced embrittlement of the reduced-activation ferritic/martensitic (RAFM) steel EUROFER97 was studied under different heat treatment conditions. Irradiation was performed in the Petten High Flux Reactor within the HFR Phase-IIb (SPICE) irradiation project up to 16.3 dpa and at different irradiation temperatures (250-450 deg. C). Several reference RAFM steels (F82H-mod, OPTIFER-Ia, GA3X and MANET-I) were also irradiated at selected temperatures. The impact properties were investigated by instrumented Charpy-V tests with subsize specimens. Embrittlement and hardening of as-delivered EUROFER97 steel are comparable to those of reference steels. Heat treatment of EUROFER97 at a higher austenitizing temperature substantially improves the embrittlement behaviour at low irradiation temperatures. Analysis of embrittlement in terms of the parameter C = {delta}DBTT/{delta}{sigma} indicates hardening-dominated embrittlement at irradiation temperatures below 350 deg. C with 0.17 {<=} C {<=} 0.53 deg. C/MPa. Scattering of C at irradiation temperatures above 400 deg. C indicates no hardening embrittlement.

  12. High-dose neutron irradiation embrittlement of RAFM steels

    Science.gov (United States)

    Gaganidze, E.; Schneider, H.-C.; Dafferner, B.; Aktaa, J.

    2006-09-01

    Neutron irradiation-induced embrittlement of the reduced-activation ferritic/martensitic (RAFM) steel EUROFER97 was studied under different heat treatment conditions. Irradiation was performed in the Petten High Flux Reactor within the HFR Phase-IIb (SPICE) irradiation project up to 16.3 dpa and at different irradiation temperatures (250-450 °C). Several reference RAFM steels (F82H-mod, OPTIFER-Ia, GA3X and MANET-I) were also irradiated at selected temperatures. The impact properties were investigated by instrumented Charpy-V tests with subsize specimens. Embrittlement and hardening of as-delivered EUROFER97 steel are comparable to those of reference steels. Heat treatment of EUROFER97 at a higher austenitizing temperature substantially improves the embrittlement behaviour at low irradiation temperatures. Analysis of embrittlement in terms of the parameter C = ΔDBTT/Δ σ indicates hardening-dominated embrittlement at irradiation temperatures below 350 °C with 0.17 ⩽ C ⩽ 0.53 °C/MPa. Scattering of C at irradiation temperatures above 400 °C indicates no hardening embrittlement.

  13. Polybutadiene and Styrene-Butadiene rubbers for high-dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Lucas N. [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Goiania, Goiania -GO (Brazil); Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil); Vieira, Silvio L. [Instituto de Fisica, Universidade Federal de Goias-UFG, Campus Samambaia, Goiania-GO (Brazil); Schimidt, Fernando [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Inhumas, Inhumas-GO (Brazil); Antonio, Patricia L.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil)

    2015-07-01

    Polybutadiene and Styrene-Butadiene are synthetical rubbers used widely for pneumatic tires manufacturing. In this research, the dosimeter characteristics of those rubbers were studied for application in high-dose dosimetry. The rubber samples were irradiated with doses of 10 Gy up to 10 kGy, using a {sup 60}Co Gamma Cell-220 system (dose rate of 1.089 kGy/h) and their readings were taken on a Fourier Transform Infrared Spectroscopy-FTIR system (model Frontier/Perkin Elmer). The ratios of two absorbance peaks were taken for each kind of rubber spectrum, Polybutadiene (1306/1130 cm{sup -1}) and Styrene-Butadiene (1449/1306 cm{sup -1}). The ratio calculated was used as the response to the irradiation, and is not uniform across the sample. From the results, it can be concluded for both rubbers: a) the dose-response curves may be useful for high-dose dosimetry (greater than 250 Gy); b) their response for reproducibility presented standard deviations lower than 2.5%; c) the relative sensitivity was higher for Styrene-Butadiene (1.86 kGy{sup -1}) than for Polybutadiene (1.81 kGy{sup -1}), d) for doses of 10 kGy to 200 kGy, there was no variation in the dosimetric response. Both types of rubber samples showed usefulness as high-dose dosimeters. (authors)

  14. HIGH DOSE FRACTION RADIOTHERAPY FOR MUCOSAL MALIGNANT MELANOMA OF THE HEAD AND NECK

    Institute of Scientific and Technical Information of China (English)

    Liu Xiuying; Li Huiling; Zheng Tianrong; Lin Xiangsong

    1998-01-01

    Objective:To evatuate the results of high dose fraction radiotherapy for mucosal malignant melanoma of the head and neck (HNMM). Methods: From 1984-1994, 35 patients with HNMM were enrolled in this study. Among them, 27 cases localized to the nasal cavity or para-nasal sinus, 8 to the oral cavity. All patients received high dose fraction radiotherapy (6--8 Gy/fraction)with the total dose ranged from 40 to 60 Gy. Results: The minimum follow-up was 2 years (ranged 2-7 years). The overall 3- and 5-year survival rate was 45.7% and 24%,respectively. Conclusion: High dose fraction radiotherapy is effective for local control of HNMM.

  15. Polycarbonate-based benzo-δ-sultam films for high-dose dosimetry in radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Feizi, Shazad [University of Tehran, Tehran (India). School of Chemistry; Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School; Ziaie, Farhood [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School; Ghandi, Mehdi [University of Tehran, Tehran (India). School of Chemistry

    2015-05-01

    In this work characteristics of the polycarbonate films with 20 μm in thickness containing different weight percentage of Benzo-δ-sultam were studied for use as a high dose dosimetry system in radiation processing facilities. The sensitivity of the dosimeters and the linearity of dose-response curves were investigated under {sup 60}Co γ-rays in a dose range of 0-100 kGy, and obtained results were compared with the commercial CTA and FWT film dosimeters. The results show that the absorbance at 348 nm depends linearly on the dose in the investigated dose range. The effects of pre-irradiation (shelf-life) and post-irradiation storage in dark and in indirect sunlight are also discussed. The results show that the dosimeters characteristics are stable within 1% at 25 C, 3 months after the irradiation.

  16. Is High Dose Therapy Superior to Conventional Dose Therapy as Initial Treatment for Relapsed Germ Cell Tumors? The TIGER Trial

    Directory of Open Access Journals (Sweden)

    Darren R. Feldman, Robert Huddart, Emma Hall, Jörg Beyer, Thomas Powles

    2011-01-01

    Full Text Available Metastatic germ cell tumours (GCTs are usually cured with cisplatin based chemotherapy and standard treatment algorithms are established. However when this treatment fails and the disease relapses, standard treatment is much more uncertain. Both conventional dose therapy (CDT and high dose therapy (HDT are widely used, due to the lack of conclusive data supporting one specific approach. A recent retrospective analysis focusing on this population suggested a significant benefit for HDT. Retrospective analyses are prone to bias, and therefore while this data is provocative it is by no mean conclusive. For this reason the international community is supporting a prospective randomised trial in this area comparing CDT(TIP with sequential HDT (TICE. The planned open labelled randomised phase III study (TIGER is due to open in 2011 and will recruit 390 patients to detect a 13% difference in 2 year progression free survival (primary endpoint. It is hoped that this large study will conclusively resolve the uncertainty which currently exists.

  17. High dose rate versus low dose rate brachytherapy for oral cancer--a meta-analysis of clinical trials.

    Directory of Open Access Journals (Sweden)

    Zhenxing Liu

    Full Text Available OBJECTIVE: To compare the efficacy and safety of high dose rate (HDR and low dose rate (LDR brachytherapy in treating early-stage oral cancer. DATA SOURCES: A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies. STUDY SELECTION: Only randomized controlled trials (RCT and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III were of interest. DATA EXTRACTION AND SYNTHESIS: Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62-2.01, overall mortality (OR = 1.01, CI 95% 0.61-1.66 and Grade 3/4 complications (OR = 0.86, CI 95% 0.52-1.42. CONCLUSIONS: This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.

  18. PLUTONIUM/HIGH-LEVEL VITRIFIED WASTE BDBE DOSE CALCULATION

    Energy Technology Data Exchange (ETDEWEB)

    D.C. Richardson

    2003-03-19

    In accordance with the Nuclear Waste Policy Amendments Act of 1987, Yucca Mountain was designated as the site to be investigated as a potential repository for the disposal of high-level radioactive waste. The Yucca Mountain site is an undeveloped area located on the southwestern edge of the Nevada Test Site (NTS), about 100 miles northwest of Las Vegas. The site currently lacks rail service or an existing right-of-way. If the Yucca Mountain site is found suitable for the repository, rail service is desirable to the Office of Civilian Waste Management (OCRWM) Program because of the potential of rail transportation to reduce costs and to reduce the number of shipments relative to highway transportation. A Preliminary Rail Access Study evaluated 13 potential rail spur options. Alternative routes within the major options were also developed. Each of these options was then evaluated for potential land use conflicts and access to regional rail carriers. Three potential routes having few land use conflicts and having access to regional carriers were recommended for further investigation. Figure 1-1 shows these three routes. The Jean route is estimated to be about 120 miles long, the Carlin route to be about 365 miles long, and Caliente route to be about 365 miles long. The remaining ten routes continue to be monitored and should any of the present conflicts change, a re-evaluation of that route will be made. Complete details of the evaluation of the 13 routes can be found in the previous study. The DOE has not identified any preferred route and recognizes that the transportation issues need a full and open treatment under the National Environmental Policy Act. The issue of transportation will be included in public hearings to support development of the Environmental Impact Statement (EIS) proceedings for either the Monitored Retrievable Storage Facility or the Yucca Mountain Project or both.

  19. Influence of adjacent low-dose fields on tolerance to high doses of protons in rat cervical spinal cord

    NARCIS (Netherlands)

    Bijl, HP; van Luijk, P; Coppes, RP; Schippers, JM; Konings, AWT; van der Kogel, AJ

    2006-01-01

    Purpose: The dose-response relationship for a relatively short length (4 mm) of rat spinal cord has been shown to be significantly modified by adjacent low-dose fields. In an additional series of experiments, we have now established the dose-volume dependence of this effect. Methods and Materials: W

  20. Novel oxytocin receptor variants in laboring women requiring high doses of oxytocin.

    Science.gov (United States)

    Reinl, Erin L; Goodwin, Zane A; Raghuraman, Nandini; Lee, Grace Y; Jo, Erin Y; Gezahegn, Beakal M; Pillai, Meghan K; Cahill, Alison G; de Guzman Strong, Cristina; England, Sarah K

    2017-08-01

    Although oxytocin commonly is used to augment or induce labor, it is difficult to predict its effectiveness because oxytocin dose requirements vary significantly among women. One possibility is that women requiring high or low doses of oxytocin have variations in the oxytocin receptor gene. To identify oxytocin receptor gene variants in laboring women with low and high oxytocin dosage requirements. Term, nulliparous women requiring oxytocin doses of ≤4 mU/min (low-dose-requiring, n = 83) or ≥20 mU/min (high-dose-requiring, n = 104) for labor augmentation or induction provided consent to a postpartum blood draw as a source of genomic DNA. Targeted-amplicon sequencing (coverage >30×) with MiSeq (Illumina) was performed to discover variants in the coding exons of the oxytocin receptor gene. Baseline relevant clinical history, outcomes, demographics, and oxytocin receptor gene sequence variants and their allele frequencies were compared between low-dose-requiring and high-dose-requiring women. The Scale-Invariant Feature Transform algorithm was used to predict the effect of variants on oxytocin receptor function. The Fisher exact or χ(2) tests were used for categorical variables, and Student t tests or Wilcoxon rank sum tests were used for continuous variables. A P value labor induction and required prostaglandins. High-dose-requiring women were more likely to undergo cesarean delivery for first-stage arrest and less likely to undergo cesarean delivery for nonreassuring fetal status. Targeted sequencing of the oxytocin receptor gene in the total cohort (n = 187) revealed 30 distinct coding variants: 17 nonsynonymous, 11 synonymous, and 2 small structural variants. One novel variant (A243T) was found in both the low- and high-dose-requiring groups. Three novel variants (Y106H, A240_A249del, and P197delfs*206) resulting in an amino acid substitution, loss of 9 amino acids, and a frameshift stop mutation, respectively, were identified only in low-dose

  1. Neutron spectra and dose equivalents calculated in tissue for high-energy radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kry, Stephen F.; Howell, Rebecca M.; Salehpour, Mohammad; Followill, David S. [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States)

    2009-04-15

    Neutrons are by-products of high-energy radiation therapy and a source of dose to normal tissues. Thus, the presence of neutrons increases a patient's risk of radiation-induced secondary cancer. Although neutrons have been thoroughly studied in air, little research has been focused on neutrons at depths in the patient where radiosensitive structures may exist, resulting in wide variations in neutron dose equivalents between studies. In this study, we characterized properties of neutrons produced during high-energy radiation therapy as a function of their depth in tissue and for different field sizes and different source-to-surface distances (SSD). We used a previously developed Monte Carlo model of an accelerator operated at 18 MV to calculate the neutron fluences, energy spectra, quality factors, and dose equivalents in air and in tissue at depths ranging from 0.1 to 25 cm. In conjunction with the sharply decreasing dose equivalent with increased depth in tissue, the authors found that the neutron energy spectrum changed drastically as a function of depth in tissue. The neutron fluence decreased gradually as the depth increased, while the average neutron energy decreased sharply with increasing depth until a depth of approximately 7.5 cm in tissue, after which it remained nearly constant. There was minimal variation in the quality factor as a function of depth. At a given depth in tissue, the neutron dose equivalent increased slightly with increasing field size and decreasing SSD; however, the percentage depth-dose equivalent curve remained constant outside the primary photon field. Because the neutron dose equivalent, fluence, and energy spectrum changed substantially with depth in tissue, we concluded that when the neutron dose equivalent is being determined at a depth within a patient, the spectrum and quality factor used should be appropriate for depth rather than for in-air conditions. Alternately, an appropriate percent depth-dose equivalent curve

  2. 3D-printed applicators for high dose rate brachytherapy: Dosimetric assessment at different infill percentage.

    Science.gov (United States)

    Ricotti, Rosalinda; Vavassori, Andrea; Bazani, Alessia; Ciardo, Delia; Pansini, Floriana; Spoto, Ruggero; Sammarco, Vittorio; Cattani, Federica; Baroni, Guido; Orecchia, Roberto; Jereczek-Fossa, Barbara Alicja

    2016-12-01

    Dosimetric assessment of high dose rate (HDR) brachytherapy applicators, printed in 3D with acrylonitrile butadiene styrene (ABS) at different infill percentage. A low-cost, desktop, 3D printer (Hamlet 3DX100, Hamlet, Dublin, IE) was used for manufacturing simple HDR applicators, reproducing typical geometries in brachytherapy: cylindrical (common in vaginal treatment) and flat configurations (generally used to treat superficial lesions). Printer accuracy was investigated through physical measurements. The dosimetric consequences of varying the applicator's density by tuning the printing infill percentage were analysed experimentally by measuring depth dose profiles and superficial dose distribution with Gafchromic EBT3 films (International Specialty Products, Wayne, NJ). Dose distributions were compared to those obtained with a commercial superficial applicator. Measured printing accuracy was within 0.5mm. Dose attenuation was not sensitive to the density of the material. Surface dose distribution comparison of the 3D printed flat applicators with respect to the commercial superficial applicator showed an overall passing rate greater than 94% for gamma analysis with 3% dose difference criteria, 3mm distance-to-agreement criteria and 10% dose threshold. Low-cost 3D printers are a promising solution for the customization of the HDR brachytherapy applicators. However, further assessment of 3D printing techniques and regulatory materials approval are required for clinical application. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Assessment of The Dose-Response Relationship of Radiation-Induced Bystander Effect in Two Cell Lines Exposed to High Doses of Ionizing Radiation (6 and 8 Gy).

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Khademi, Sara; Azimian, Hosein; Mohebbi, Shokoufeh; Soleymanifard, Shokouhozaman

    2017-10-01

    The dose-response relationship of radiation-induced bystander effect (RIBE) is controversial at high dose levels. The aim of the present study is to assess RIBE at high dose levels by examination of different endpoints. This experimental study used the medium transfer technique to induce RIBE. The cells were divided into two main groups: QU-DB cells which received medium from autologous irradiated cells and MRC5 cells which received medium from irradiated QU-DB cells. Colony, MTT, and micronucleus assays were performed to quantify bystander responses. The medium was diluted and transferred to bystander cells to investigate whether medium dilution could revive the RIBE response that disappeared at a high dose. The RIBE level in QU-DB bystander cells increased in the dose range of 0.5 to 4 Gy, but decreased at 6 and 8 Gy. The Micronucleated cells per 1000 binucleated cells (MNBN) frequency of QU-DB bystander cells which received the most diluted medium from 6 and 8 Gy QU-DB irradiated cells reached the maximum level compared to the MNBN frequency of the cells that received complete medium (Pbystander cells. This finding confirmed that a negative feedback mechanism was responsible for the decrease in RIBE response at high doses. Decrease of RIBE at high doses might be used to predict that in radiosurgery, brachytherapy and grid therapy, in which high dose per fraction is applied, normal tissue damage owing to RIBE may decrease.

  4. Impact of therapeutic and high doses of florfenicol on kidney and liver functional indicators in goat

    Directory of Open Access Journals (Sweden)

    Jan Muhammad Shah

    2016-10-01

    Full Text Available Aim: The aim of this study was to evaluate the impact of therapeutic and high doses of florfenicol on kidney and liver functional indicators in goat species. Materials and Methods: Six mature, healthy goats (combine breed and sex with average weight 25 kg were selected for this study. The therapeutic (20 mg/kg b.w. and high doses (40 and 60 mg of florfenicol were administered for 3 days with 24 h interval. Blood samples were collected at 0, 24, 48, 72, 96, and 120 h following the each administered dose. Results: The results showed that the therapeutic dose of florfenicol produced nonsignificant effect on serum urea, creatinine, total protein (TP, alkaline phosphatase (ALP, gamma-glutamyl transferase (GGT and bilirubin on all timings, and increased (p<0.05 the serum glutamic oxaloacetic transaminase (SGOT and serum glutamate-pyruvate transaminase (SGPT levels for 48 h. Whereas the high doses of florfenicol (40 and 60 mg significantly altered the kidney and liver functional indicators in the blood. In contrast with control, the serum urea level was (p<0.01 increased at all timing points. Creatinine values were altered (p<0.01, <0.05 in increasing manner from 24 to 96 h. The high dose of 40 mg decreased the TP (p<0.05 for 72 h and 60 mg persisted same effect (p<0.01 up to 120 h. The indices of ALP, GGT, SGOT, and SGPT were raised (p<0.01, <0.05 at all timings. The bilirubin indexes also (p<0.05 elevated from 48 to 72. Conclusion: It was concluded that the high doses of florfenicol produced reversible dose-dependent effects on functional indicators of kidney and liver such as urea, creatinine, TP, ALP, SGOT, SGPT, GGT, and bilirubin.

  5. Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer

    OpenAIRE

    2015-01-01

    Purpose In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This study evaluates relevant dose parameters in cervix brachytherapy in order to assess existing tandem-ring dwell time ratio used at the first HDR BT center in Nigeria, and compare it with an alternative s...

  6. High doses of pseudoephedrine hydrochloride accelerate onset of CNS oxygen toxicity seizures in unanesthetized rats.

    Science.gov (United States)

    Pilla, R; Held, H E; Landon, C S; Dean, J B

    2013-08-29

    Pseudoephedrine (PSE) salts (hydrochloride and sulfate) are commonly used as nasal and paranasal decongestants by scuba divers. Anecdotal reports from the Divers Alert Network suggest that taking PSE prior to diving while breathing pure O₂ increases the risk for CNS oxygen toxicity (CNS-OT), which manifests as seizures. We hypothesized that high doses of PSE reduce the latency time to seizure (LS) in unanesthetized rats breathing 5 atmospheres absolute (ATA) of hyperbaric oxygen. Sixty-three male rats were implanted with radio-transmitters that recorded electroencephalogram activity and body temperature. After ≥7-day recovery, and 2 h before "diving", each rat was administered either saline solution (control) or PSE hydrochloride intragastrically at the following doses (mg PSE/kg): 0, 40, 80, 100, 120, 160, and 320. Rats breathed pure O₂ and were dived to 5ATA until the onset of behavioral seizures coincident with neurological seizures. LS was the time elapsed between reaching 5ATA and exhibiting seizures. We observed a significant dose-dependent decrease in the LS at doses of 100-320 mg/kg, whereas no significant differences in LS from control value were observed at doses ≤80 mg/kg. Our findings showed that high doses of PSE accelerate the onset of CNS-OT seizures in unanesthetized rats breathing 5ATA of poikilocapnic hyperoxia. Extrapolating our findings to humans, we conclude that the recommended daily dose of PSE should not be abused prior to diving with oxygen-enriched gas mixes or pure O₂.

  7. Image-guided high-dose-rate brachytherapy in inoperable endometrial cancer

    Science.gov (United States)

    Petsuksiri, J; Chansilpa, Y; Hoskin, P J

    2014-01-01

    Inoperable endometrial cancer may be treated with curative aim using radical radiotherapy alone. The radiation techniques are external beam radiotherapy (EBRT) alone, EBRT plus brachytherapy and brachytherapy alone. Recently, high-dose-rate brachytherapy has been used instead of low-dose-rate brachytherapy. Image-guided brachytherapy enables sufficient coverage of tumour and reduction of dose to the organs at risk, thus increasing the therapeutic ratio of treatment. Local control rates with three-dimensional brachytherapy appear better than with conventional techniques (about 90–100% and 70–90%, respectively). PMID:24807067

  8. Application of RADPOS in Vivo Dosimetry for QA of High Dose Rate Brachytherapy

    DEFF Research Database (Denmark)

    Cherpak, A.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Cygler, J.

    2012-01-01

    Gy. Conclusions: In vivo dosimetry can potentially signal errors in catheter placement or numbering before entire dose is delivered. The demonstrated accuracy of RADPOS dose measurements and its ability to simultaneously measure displacement makes it a powerful tool for HDR brachytherapy treatments for prostate...... cancer, where high dose gradients and movement of the prostate gland can present unique in vivo dosimetry challenges. Financial and technical support has been received from Best Medical Canada and Ascension Technology Corporation. © 2012 American Association of Physicists in Medicine...

  9. Dose equivalent measurements in mixed and time varying radiation fields around high-energy accelerators

    CERN Document Server

    Mayer, S

    2003-01-01

    Measurements of ambient dose equivalent in stray radiation fields behind the shielding of high-energy accelerators are a challenging task. Several radiation components (photons, neutrons, charged particles, muons, etc.), spanning a wide range of energies, contribute to the total dose equivalent. The radiation fields are produced by beam losses interacting with structural material during the acceleration or at the ejection to experimental areas or other accelerators. The particle beam is usually not continuous but separated in "bunches" or pulses, which further complicates dose measurements at high-energy accelerators. An ideal dosimeter for operational radiation protection should measure dose equivalent for any composition of radiation components in the entire energy range even when the field is strongly pulsed. The objective of this work was to find out if an ionisation chamber operated as a "recombination chamber" and a TEPC instrument using the variance-covariance method ("Sievert Instrument") are capable ...

  10. Dose equivalent measurements in mixed and time varying radiation fields around high-energy accelerators

    CERN Document Server

    Mayer, S

    2003-01-01

    Measurements of ambient dose equivalent in stray radiation fields behind the shielding of high-energy accelerators are a challenging task. Several radiation components (photons, neutrons, charged particles, muons, etc.), spanning a wide range of energies, contribute to the total dose equivalent. The radiation fields are produced by beam losses interacting with structural material during the acceleration or at the ejection to experimental areas or other accelerators. The particle beam is usually not continuous but separated in "bunches" or pulses, which further complicates dose measurements at high-energy accelerators. An ideal dosimeter for operational radiation protection should measure dose equivalent for any composition of radiation components in the entire energy range even when the field is strongly pulsed. The objective of this work was to find out if an ionisation chamber operated as a "recombination chamber" and a TEPC instrument using the variance-covariance method ("Sievert Instrument") are capable ...

  11. On LiF:Mg,Cu,P and LiF:Mg,Ti phosphors high & ultra-high dose features

    CERN Document Server

    Obryk, Barbara; de Barros, Vinicius S; Guzzo, Pedro L; Bilski, Paweł

    2013-01-01

    LiF:Mg,Ti and LiF:Mg,Cu,P are well known thermoluminescence (TL) dosimetry materials since many years. A few years ago their properties seemed well known and it was widely believed that they are not suitable for the measurement of doses above the saturation level of the TL signal, which for both materials occur at about 1 kGy. The high-dose high-temperature TL emission of LiF:Mg,Cu,P observed at the IFJ in 2006, which above 30 kGy takes the form of the so-called TL peak B, opened the way to use this material for measuring the dose in the high and ultra-high range, in particular for the monitoring of ionizing radiation around the essential electronic elements of high-energy accelerators, also fission and fusion facilities, as well as for emergency dosimetry. This discovery initiated studies of high and ultra-high dose characteristics of both of these phosphors, which turned out to be significantly different in many aspects. These studies not only strive to refine the method for measuring high doses based on th...

  12. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F.

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients. PMID:26820986

  13. The response of various neutron dose meters considering the application at a high energy particle accelerator

    CERN Document Server

    Gutermuth, F; Fehrenbacher, G; Festag, J G

    2003-01-01

    The applicability of several neutron detectors for dose measurements at a neutron field typical for high energy particle accelerators is investigated. The response of four commercially available active neutron dose meters and two passive detectors to neutrons from a sup 2 sup 4 sup 1 Am-Be(alpha,n) source and to neutrons at the CERN EU high energy reference field was determined experimentally and simulated using the Monte-Carlo code FLUKA. Fluence response functions and dose responses for the different detectors were calculated in the energy range between 1 keV and 10 GeV. The results show that the dose response to the high energy neutron field at CERN of the conventional rem-counters is lower by a factor of 2 to 2.5 if compared to the dose response to a sup 2 sup 4 sup 1 Am-Be(alpha,n) neutron source. The rem-counters exhibiting an additional layer of lead inside the moderating structure showed dose readings which differ only up to 25%. A thermoluminescent based neutron detector was tested for comparison. Th...

  14. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients.

  15. Efeitos das isoflavonas em altas doses sobre o útero da rata Effects of high-dose isoflavones on rat uterus

    Directory of Open Access Journals (Sweden)

    Adriana Aparecida Ferraz Carbonel

    2011-10-01

    Full Text Available OBJETIVO: Avaliar o efeito de altas doses de isoflavonas no útero de ratas adultas castradas. MÉTODOS: Ratas virgens ovariectomizadas (n = 40 foram tratadas por 30 dias consecutivos com veículo (GCtrl ou genisteína nas concentrações 42 (GES42, 125 (GES125 e 250 (GES250 µg/g de peso corporal ao dia. O extrato de soja e o veículo (propilenoglicol foram administrados por gavagem. Ao final do experimento, foi realizada dosagem sérica de 17 β-estradiol e progesterona, avaliou-se o peso dos animais e dos úteros e foi feito exame colpocitológico. Fragmentos do terço médio dos cornos uterinos foram fixados em formol a 10% e processados para inclusão em parafina para estudo histológico. Cortes de 5 µm de espessura foram corados pelo HE e destinados a estudo em microscopia de luz. Analisou-se a histomorfologia do endométrio, área endometrial, número e área ocupada pelas glândulas, assim como a concentração de eosinófilos presentes na lâmina própria. Os dados numéricos obtidos foram submetidos à análise de variância complementada pelo teste de Tukey-Kramer (p GES125 do que nos outros grupos (GES250 > GES125 > GES42 = GCtrl; p OBJECTIVE: To evaluate the effects of high-dose isoflavones on the uterus of castrated adult rats. METHODS: Adult, ovariectomized virgin rats (n = 40 were treated by gavage during 30 consecutive days with vehicle (propylene glycol, group GCtrl or different doses of genistein: 42 (group GES42, 125 (GES125, or 250 (GES250 µg/g body weight per day. Animals were killed, weighed, vaginal and uterine samples were taken for cytologic evaluation, and serum levels of 17 β-estradiol and progesterone were determined. The middle third of the uterine horns was dissected, fixed in 10% formaldehyde and processed for paraffin inclusion; 5-µm thick sections were obtained and stained with HE for further histological study under light microscopy. The endometrial morphology and area, number and area of glands, and number

  16. Application of TL dosemeters for dose distribution measurements at high temperatures in nuclear reactors.

    Science.gov (United States)

    Osvay, M; Deme, S

    2006-01-01

    Al2O3:Mg,Y ceramic thermoluminescence dosemeters were developed at the Institute of Isotopes for high dose applications at room temperatures. The glow curve of Al2O3:Mg,Y exhibits two peaks--one at 250 degrees C (I) and another peak at approximately 400 degrees C (II). In order to extend the application of these dosemeters to high temperatures, the effect of irradiation temperature was investigated using temperature controlled heating system during high dose irradiation at various temperatures (20-100 degrees C). The new calibration and measuring method has been successfully applied for dose mapping within the hermetic zone of the Paks Nuclear Power Plant even at high temperature parts of blocks.

  17. Monitor units are not predictive of neutron dose for high-energy IMRT

    Directory of Open Access Journals (Sweden)

    Hälg Roger A

    2012-08-01

    Full Text Available Abstract Background Due to the substantial increase in beam-on time of high energy intensity-modulated radiotherapy (>10 MV techniques to deliver the same target dose compared to conventional treatment techniques, an increased dose of scatter radiation, including neutrons, is delivered to the patient. As a consequence, an increase in second malignancies may be expected in the future with the application of intensity-modulated radiotherapy. It is commonly assumed that the neutron dose equivalent scales with the number of monitor units. Methods Measurements of neutron dose equivalent were performed for an open and an intensity-modulated field at four positions: inside and outside of the treatment field at 0.2 cm and 15 cm depth, respectively. Results It was shown that the neutron dose equivalent, which a patient receives during an intensity-modulated radiotherapy treatment, does not scale with the ratio of applied monitor units relative to an open field irradiation. Outside the treatment volume at larger depth 35% less neutron dose equivalent is delivered than expected. Conclusions The predicted increase of second cancer induction rates from intensity-modulated treatment techniques can be overestimated when the neutron dose is simply scaled with monitor units.

  18. The neutron dose equivalent around high energy medical electron linear accelerators

    Directory of Open Access Journals (Sweden)

    Poje Marina

    2014-01-01

    Full Text Available The measurement of neutron dose equivalent was made in four dual energy linear accelerator rooms. Two of the rooms were reconstructed after decommissioning of 60Co units, so the main limitation was the space. The measurements were performed by a nuclear track etched detectors LR-115 associated with the converter (radiator that consist of 10B and with the active neutron detector Thermo BIOREM FHT 742. The detectors were set at several locations to evaluate the neutron ambient dose equivalent and/or neutron dose rate to which medical personnel could be exposed. Also, the neutron dose dependence on collimator aperture was analyzed. The obtained neutron dose rates outside the accelerator rooms were several times smaller than the neutron dose rates inside the accelerator rooms. Nevertheless, the measured neutron dose equivalent was not negligible from the aspect of the personal dosimetry with almost 2 mSv a year per person in the areas occupied by staff (conservative estimation. In rooms with 15 MV accelerators, the neutron exposure to the personnel was significantly lower than in the rooms having 18 MV accelerators installed. It was even more pronounced in the room reconstructed after the 60Co decommissioning. This study confirms that shielding from the neutron radiation should be considered when building vaults for high energy linear accelerators, especially when the space constraints exist.

  19. High and Low Doses of Ionizing Radiation Induce Different Secretome Profiles in a Human Skin Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qibin; Matzke, Melissa M.; Schepmoes, Athena A.; Moore, Ronald J.; Webb-Robertson, Bobbie-Jo M.; Hu, Zeping; Monroe, Matthew E.; Qian, Weijun; Smith, Richard D.; Morgan, William F.

    2014-03-18

    It is postulated that secreted soluble factors are important contributors of bystander effect and adaptive responses observed in low dose ionizing radiation. Using multidimensional liquid chromatography-mass spectrometry based proteomics, we quantified the changes of skin tissue secretome – the proteins secreted from a full thickness, reconstituted 3-dimensional skin tissue model 48 hr after exposure to 3, 10 and 200 cGy of X-rays. Overall, 135 proteins showed statistical significant difference between the sham (0 cGy) and any of the irradiated groups (3, 10 or 200 cGy) on the basis of Dunnett adjusted t-test; among these, 97 proteins showed a trend of downregulation and 9 proteins showed a trend of upregulation with increasing radiation dose. In addition, there were 21 and 8 proteins observed to have irregular trends with the 10 cGy irradiated group either having the highest or the lowest level among all three radiated doses. Moreover, two proteins, carboxypeptidase E and ubiquitin carboxyl-terminal hydrolase isozyme L1 were sensitive to ionizing radiation, but relatively independent of radiation dose. Conversely, proteasome activator complex subunit 2 protein appeared to be sensitive to the dose of radiation, as rapid upregulation of this protein was observed when radiation doses were increased from 3, to 10 or 200 cGy. These results suggest that different mechanisms of action exist at the secretome level for low and high doses of ionizing radiation.

  20. Amorphous and crystalline optical materials used as instruments for high gamma radiation doses estimations

    Energy Technology Data Exchange (ETDEWEB)

    Ioan, M-R., E-mail: razvan.ioan@nipne.ro

    2016-06-15

    Highlights: • The damage induced by gamma rays to optical materials was highlighted and quantified, using laser techniques. • Polarized light and the particularities of the laser light (monochromaticity, directionality and coherence) were used. • The correlation between the damage and the gamma rays absorbed dose was made. • The comparison between different types of optical materials and their dose related calibrations were made. • The uncertainty associated to the technique was determined. - Abstract: Nuclear radiation induce some changes to the structure of exposed materials. The main effect of ionizing radiation when interacting with optical materials is the occurrence of color centers, which are quantitatively proportional to the up-taken doses. In this paper, a relation between browning effect magnitude and dose values was found. Using this relation, the estimation of a gamma radiation dose can be done. By using two types of laser wavelengths (532 nm and 633 nm), the optical powers transmitted thru glass samples irradiated to different doses between 0 and 59.1 kGy, were measured and the associated optical browning densities were determined. The use of laser light gives the opportunity of using its particularities: monochromaticity, directionality and coherence. Polarized light was also used for enhancing measurements quality. These preliminary results bring the opportunity of using glasses as detectors for the estimation of the dose in a certain point in space and for certain energy, especially in particles accelerators experiments, where the occurred nuclear reactions are involving the presence of high gamma rays fields.

  1. High-dose insulin inhibits gap junction intercellular communication in vascular smooth muscle cells.

    Science.gov (United States)

    Bian, Ou; Zhang, Haishan; Guan, Qigang; Sun, Yingxian; Zeng, Dingyin

    2015-07-01

    Gap junction intercellular communication (GJIC) is important in mediating intercellular substance and signal transmission. Connexin (Cx)43 is a major component involved in GJIC in vascular tissue and its abnormal expression is closely associated with various vascular diseases. Insulin resistance is the central component of metabolic syndrome, and high doses of insulin can affect vascular function through multiple pathways, resulting in cardiovascular disease. However, the effects of insulin on GJIC function and connexin (Cx)43 expression in vascular smooth muscle cells (VSMCs) remain unclear. Following treatment of VSMCs with different doses of insulin, a fluorescence recovery after photobleaching (FRAP) assay was performed to evaluate GJIC function in treated VSMCs. The results showed that high‑dose insulin suppressed GJIC function. Western blot assays further demonstrated that high‑dose insulin induced the phosphorylation of Cx43 at s368 and downregulated the expression of Cx43. H2O2 release assays demonstrated that high‑dose insulin treatment significantly elevated the cellular H2O2 level. In addition, compared with cells treated with high‑dose insulin, pretreatment with catalase significantly restored the cellular GJIC function, decreased the phosphorylation level of Cx43 at s368, and enhanced Cx43 expression. In conclusion, these data indicate that high‑dose insulin inhibits cellular GJIC function through the oxidative stress‑activated signaling pathway. This phenomenon may also constitute a potential mechanism underlying the pathogenesis of insulin resistance and its complications.

  2. Comparative dosimetry of GammaMed Plus high-dose rate 192 Ir brachytherapy source

    Directory of Open Access Journals (Sweden)

    Patel N

    2010-01-01

    Full Text Available The comparative dosimetry of GammaMed (GM Plus high-dose rate brachytherapy source was performed by an experiment using 0.1-cc thimble ionization chamber and simulation-based study using EGSnrc code. In-water dose measurements were performed with 0.1-cc chamber to derive the radial dose function (r = 0.8 to 20.0 cm and anisotropy function (r = 5.0 cm with polar angle from 10° to 170°. The nonuniformity correction factor for 0.1-cc chamber was applied for in-water measurements at shorter distances from the source. The EGSnrc code was used to derive the dose rate constant (L, radial dose function g L (r and anisotropy function F(r, q of GM Plus source. The dosimetric data derived using EGSnrc code in our study were in very good agreement relative to published data for GM Plus source. The radial dose function up to 12 cm derived from measured dose using 0.1-cc chamber was in agreement within ±3% of data derived by the simulation study.

  3. High-dose vaginal maintenance metronidazole for recurrent bacterial vaginosis: a pilot study.

    Science.gov (United States)

    Aguin, Tina; Akins, Robert A; Sobel, Jack D

    2014-05-01

    The purpose of this study was to explore the benefit of high-dose intravaginal metronidazole as a maintenance therapy in reducing recurrence rates of bacterial vaginosis (BV). Eighteen women with a history of recurrent BV and symptomatic BV were treated with metronidazole 750 mg suppository intravaginally daily for 7 days. Those in remission by Amsel criteria received metronidazole 750 mg twice weekly for 3 months with further follow-up for 3 months. High-dose metronidazole intravaginally was associated with rare clinical recurrence during the period of use. After cessation of suppression therapy, recurrence was high.

  4. High dose zinc supplementation induces hippocampal zinc deficiency and memory impairment with inhibition of BDNF signaling.

    Directory of Open Access Journals (Sweden)

    Yang Yang

    Full Text Available Zinc ions highly concentrate in hippocampus and play a key role in modulating spatial learning and memory. At a time when dietary fortification and supplementation of zinc have increased the zinc consuming level especially in the youth, the toxicity of zinc overdose on brain function was underestimated. In the present study, weaning ICR mice were given water supplemented with 15 ppm Zn (low dose, 60 ppm Zn (high dose or normal lab water for 3 months, the behavior and brain zinc homeostasis were tested. Mice fed high dose of zinc showed hippocampus-dependent memory impairment. Unexpectedly, zinc deficiency, but not zinc overload was observed in hippocampus, especially in the mossy fiber-CA3 pyramid synapse. The expression levels of learning and memory related receptors and synaptic proteins such as NMDA-NR2A, NR2B, AMPA-GluR1, PSD-93 and PSD-95 were significantly decreased in hippocampus, with significant loss of dendritic spines. In keeping with these findings, high dose intake of zinc resulted in decreased hippocampal BDNF level and TrkB neurotrophic signaling. At last, increasing the brain zinc level directly by brain zinc injection induced BDNF expression, which was reversed by zinc chelating in vivo. These results indicate that zinc plays an important role in hippocampus-dependent learning and memory and BDNF expression, high dose supplementation of zinc induces specific zinc deficiency in hippocampus, which further impair learning and memory due to decreased availability of synaptic zinc and BDNF deficit.

  5. High dose zinc supplementation induces hippocampal zinc deficiency and memory impairment with inhibition of BDNF signaling.

    Science.gov (United States)

    Yang, Yang; Jing, Xiao-Peng; Zhang, Shou-Peng; Gu, Run-Xia; Tang, Fang-Xu; Wang, Xiu-Lian; Xiong, Yan; Qiu, Mei; Sun, Xu-Ying; Ke, Dan; Wang, Jian-Zhi; Liu, Rong

    2013-01-01

    Zinc ions highly concentrate in hippocampus and play a key role in modulating spatial learning and memory. At a time when dietary fortification and supplementation of zinc have increased the zinc consuming level especially in the youth, the toxicity of zinc overdose on brain function was underestimated. In the present study, weaning ICR mice were given water supplemented with 15 ppm Zn (low dose), 60 ppm Zn (high dose) or normal lab water for 3 months, the behavior and brain zinc homeostasis were tested. Mice fed high dose of zinc showed hippocampus-dependent memory impairment. Unexpectedly, zinc deficiency, but not zinc overload was observed in hippocampus, especially in the mossy fiber-CA3 pyramid synapse. The expression levels of learning and memory related receptors and synaptic proteins such as NMDA-NR2A, NR2B, AMPA-GluR1, PSD-93 and PSD-95 were significantly decreased in hippocampus, with significant loss of dendritic spines. In keeping with these findings, high dose intake of zinc resulted in decreased hippocampal BDNF level and TrkB neurotrophic signaling. At last, increasing the brain zinc level directly by brain zinc injection induced BDNF expression, which was reversed by zinc chelating in vivo. These results indicate that zinc plays an important role in hippocampus-dependent learning and memory and BDNF expression, high dose supplementation of zinc induces specific zinc deficiency in hippocampus, which further impair learning and memory due to decreased availability of synaptic zinc and BDNF deficit.

  6. Oxidative stress and innate immunity status in chickens exposed to high dose of ascorbic acid.

    Science.gov (United States)

    Berzina, Nadezhda; Markovs, Jurijs; Dizhbite, Tatiana; Apsite, Mirdza; Vasilyeva, Svetlana; Basova, Nataliya; Smirnova, Galina; Isajevs, Sergejs

    2013-10-01

    The effects of high dose ascorbic acid (10 000 mg·kg(-1) in the diet) and the transition metal on the presence of oxidative stress in the internal organs of growing chicks, as well as on the innate immune system status, were investigated. Supplementation with a high dose of ascorbic acid had pro-inflammatory effects on the intestinal mucosa, and lysozyme levels were decreased significantly in all organs studied. High-dose ascorbic acid caused an imbalance between prooxidative and antioxidative activities and was associated with the generation of semiquinone radicals. We observed that ascorbic acid increased iron and cadmium absorption. When a high dose of ascorbic acid was applied, elevated kidney and intestinal mucosa iron concentrations were observed. The amount of free malondialdehyde in the above organs has increased as well. These data have important implications for the mechanism of the oxidative stress development under the influence of high dose of ascorbic acid, indicating the importance of the side reactions of the mitochondrial electron transport chain with the formation of semiquinone radicals and the role of transition metals in this process.

  7. Double dose: High family conflict enhances the effect of media violence exposure on adolescents’ aggression

    NARCIS (Netherlands)

    Fikkers, K.M.; Piotrowski, J.T.; Weeda, W.D.; Vossen, H.G.M.; Valkenburg, P.M.

    2013-01-01

    We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low

  8. Double dose: High family conflict enhances the effect of media violence exposure on adolescents’ aggression

    NARCIS (Netherlands)

    Fikkers, K.M.; Piotrowski, J.T.; Weeda, W.D.; Vossen, H.G.M.; Valkenburg, P.M.

    2013-01-01

    We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low conf

  9. Double dose: High family conflict enhances the effect of media violence exposure on adolescents’ aggression

    NARCIS (Netherlands)

    Fikkers, K.M.; Piotrowski, J.T.; Weeda, W.D.; Vossen, H.G.M.; Valkenburg, P.M.

    2013-01-01

    We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low conf

  10. Dose variation due to change in planned position for patients with carcinoma of the cervix undergoing high-dose-rate brachytherapy- 2D dose analysis

    Directory of Open Access Journals (Sweden)

    Anil Talluri

    2015-03-01

    Full Text Available Purpose: To assess the dosimetry to organs at risk (OARs in lithotomy position with a planned time-dose pattern obtained from supine position. Methods: The sample consists of thirty patients with carcinoma of the uterine cervix, Stage II and III. Patients often feel discomfort in supine position (S position when compared to lithotomy position (M position due to relaxation of pelvic floor muscles after the insertion of applicator (tandem and ovoids or before delivery of the treatment. Each patient was imaged with orthogonal X- ray radiographs simultaneously in two positions, i.e. S position and M position. Dwell time and dwell position pattern obtained from the optimized plan in S position was used to generate plan in M position. Following dose reference points (point A, pelvic wall points, bladder points, rectal, anorectum (AR point and rectosigmoid (RS point points were identified for analysis in S and M positions. The dosimetric data for reference points generated by the Brachyvision TPS was analyzed.Results: Pelvic wall points registered lower doses in M position when compared to S position. Mean doses for right pelvic wall point (RPW and left pelvic wall point (LPW were reduced by -10.02 % and -11.5% in M position, respectively. International Commission on Radiation Units and Measurements (ICRU bladder point also registered lower doses in M position with a mean dose of -6.8%. Rectal point showed dose reduction by mean of -6.4%. AR and RS points showed an increased dose in M position by a mean of 16.5% and 10%, respectively. Conclusion: Current dosimetry procedure serves as a model with time-dose pattern planned for S position, but delivered in M position, without dose optimization. Prioritization of comfort and position can be considered in conjunction with optimization of dose

  11. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  12. Dosimetric properties of bio minerals applied to high-dose dosimetry using the TSEE technique

    Energy Technology Data Exchange (ETDEWEB)

    Vila, G. B.; Caldas, L. V. E., E-mail: gbvila@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The study of the dosimetric properties such as reproducibility, the residual signal, lower detection dose, dose-response curve and fading of the thermally stimulated emission exo electronic (TSEE) signal of Brazilian bio minerals has shown that these materials present a potential use as radiation dosimeters. The reproducibility within ± 10% for oyster shell, mother-of-pearl and coral reef samples showed that the signal dispersion is small when compared with the mean value of the measurements. The study showed that the residual signal can be eliminated with a thermal treatment at 300 grades C/1 h. The lower detection dose of 9.8 Gy determined for the oyster shell samples when exposed to beta radiation and 1.6 Gy for oyster shell and mother-of-pearl samples when exposed to gamma radiation can be considered good, taking into account the high doses of this study. The materials presented linearity at the dose response curves in some ranges, but the lack of linearity in other cases presents no problem since a good mathematical description is possible. The fading study showed that the loss of TSEE signal can be minimized if the samples are protected from interferences such as light, heat and humidity. Taking into account the useful linearity range as the main dosimetric characteristic, the tiger shell and oyster shell samples are the most suitable for high-dose dosimetry using the TSEE technique. (Author)

  13. The Effects of Erythropoietin Dose Titration during High-Fat Diet-Induced Obesity

    Directory of Open Access Journals (Sweden)

    Amanda Foskett

    2011-01-01

    Full Text Available Erythropoietin (Epo is a pleotropic cytokine with several nonhematopoietic tissue effects. High-dose Epo treatment-mediated effects on body weight, fat mass and glucose tolerance have recently been reported, thus extending its pleotropic effects to fat and glucose metabolism. However, the exact dose range of Epo treatment required for such effects remains unidentified to date. We investigated Epo dosage effect (up to 1000 U/kg on hematocrit, body weight, body composition, glucose metabolism, food intake, and physical activity, during high-fat diet-induced obesity. We report that Epo doses (1000, 600, 300, and 150 U/kg significantly reduced body weight gain and fat mass, while, only Epo doses of 300 U/kg and higher significantly affected glucose tolerance. None of the tested Epo doses showed any detectable effects on food intake, and only 1000 U/kg dose significantly increased physical activity, suggesting that these parameters may only be partially responsible for the metabolic effects of Epo treatment.

  14. Aging of magnesium stearate under high doses gamma irradiation and oxidative conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lebeau, D.; Beuvier, L.; Cornaton, M. [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France); Miserque, F. [CEA, DEN, DPC, SCCME, LECA, F-91191 Gif-sur-Yvette (France); Tabarant, M. [CEA, DEN, DPC, SEARS, LISL, F-91191 Gif-sur-Yvette (France); Esnouf, S. [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France); Ferry, M., E-mail: muriel.ferry@cea.fr [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France)

    2015-05-15

    Highlights: • Magnesium stearate was radio-oxidized at very high doses using gamma-rays. • H{sub 2} emission was estimated as a function of the integrated dose. • Modifications in the organic solid were followed as a function of the integrated dose. • A non-exhaustive degradation mechanism of magnesium stearate was proposed. - Abstract: In nuclear waste packages conditioning processes, magnesium stearate is widely used because of its high lubricating properties. For safety purposes, the radiolytic degradation of these organic materials has to be better understood to be able to predict their aging in repository conditions. This study reports the radiolytic degradation of magnesium stearate, using gamma-rays at room temperature and under air. Modifications were followed using different analytical tools (XPS, ATR-FTIR, ICP-AES, ATG and mass spectrometry). It has been observed that molecules mainly formed up to 1000 kGy of gamma irradiation dose under radio-oxidation are alkanes, hydroperoxides, double bonds in the aliphatic chain, carboxylates with aliphatic chain shorter than the one of stearate and ketones. At a dose of 4000 kGy, dicarboxylic acids are observed: the formation of these molecules needs a dose of at least 1000 kGy to be created under radio-oxidation. These observations allow us to propose a non-exhaustive degradation mechanism of magnesium stearate under gamma-irradiation at room temperature and under air.

  15. A grid algorithm for high throughput fitting of dose-response curve data.

    Science.gov (United States)

    Wang, Yuhong; Jadhav, Ajit; Southal, Noel; Huang, Ruili; Nguyen, Dac-Trung

    2010-10-21

    We describe a novel algorithm, Grid algorithm, and the corresponding computer program for high throughput fitting of dose-response curves that are described by the four-parameter symmetric logistic dose-response model. The Grid algorithm searches through all points in a grid of four dimensions (parameters) and finds the optimum one that corresponds to the best fit. Using simulated dose-response curves, we examined the Grid program's performance in reproducing the actual values that were used to generate the simulated data and compared it with the DRC package for the language and environment R and the XLfit add-in for Microsoft Excel. The Grid program was robust and consistently recovered the actual values for both complete and partial curves with or without noise. Both DRC and XLfit performed well on data without noise, but they were sensitive to and their performance degraded rapidly with increasing noise. The Grid program is automated and scalable to millions of dose-response curves, and it is able to process 100,000 dose-response curves from high throughput screening experiment per CPU hour. The Grid program has the potential of greatly increasing the productivity of large-scale dose-response data analysis and early drug discovery processes, and it is also applicable to many other curve fitting problems in chemical, biological, and medical sciences.

  16. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Shwetha, Bondel [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Ravikumar, Manickam, E-mail: drravikumarm@gmail.com [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Supe, Sanjay S.; Sathiyan, Saminathan [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Lokesh, Vishwanath [Department of Radiotherapy, Kidwai, Memorial Institute of Oncology, Bangalore (India); Keshava, Subbarao L. [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India)

    2012-04-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  17. Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning.

    Science.gov (United States)

    Bahadur, Yasir A; Constantinescu, Camelia; Hassouna, Ashraf H; Eltaher, Maha M; Ghassal, Noor M; Awad, Nesreen A

    2015-01-01

    To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff HDR brachytherapy using a multichannel applicator. For each brachytherapy fraction, two inverse treatment plans (for central channel and multichannel loadings) were performed and compared. The advantage of fractional re-planning was also investigated. Dose-volume-histogram (DVH) analysis showed limited, but statistically significant difference (p = 0.007) regarding clinical-target-volume dose coverage between single and multichannel approaches. For the organs-at-risk rectum and bladder, the use of multichannel applicator demonstrated a noticeable dose reduction, when compared to single channel, but statistically significant for rectum only (p = 0.0001). For D2cc of rectum, an average fractional dose of 6.1 ± 0.7 Gy resulted for single channel vs. 5.1 ± 0.6 Gy for multichannel. For D2cc of bladder, an average fractional dose of 5 ± 0.9 Gy occurred for single channel vs. 4.9 ± 0.8 Gy for multichannel. The dosimetric benefit of fractional re-planning was demonstrated: DVH analysis showed large, but not statistically significant differences between first fraction plan and fractional re-planning, due to large inter-fraction variations for rectum and bladder positioning and filling. Vaginal HDR brachytherapy using a multichannel vaginal applicator and inverse planning provides dosimetric advantages over single channel cylinder, by reducing the dose to organs at risk without compromising the target volume coverage, but at the expense of an increased vaginal mucosa dose. Due to large inter-fraction dose variations, we recommend individual fraction treatment plan optimization.

  18. The Effect of High-Dose Ionizing Radiation on the Astrobiological Model Lichen Circinaria gyrosa

    Science.gov (United States)

    de la Torre, Rosa; Zélia Miller, Ana; Cubero, Beatriz; Martín-Cerezo, M. Luisa; Raguse, Marina; Meeßen, Joachim

    2017-02-01

    The lichen Circinaria gyrosa is an astrobiological model defined by its high capacity of resistance to space conditions and to a simulated martian environment. Therefore, it became part of the currently operated BIOMEX experiment on board the International Space Station and the recent STARLIFE campaign to study the effects of four types of space-relevant ionizing radiation. The samples were irradiated with helium and iron ions at doses up to 2 kGy, with X-rays at doses up to 5 kGy and with γ rays at doses from 6 to 113 kGy. Results on C. gyrosa's resistance to simulated space ionizing radiation and its post-irradiation viability were obtained by (i) chlorophyll a fluorescence of photosystem II (PSII), (ii) epifluorescence microscopy, (iii) confocal laser scanning microscopy (CLSM), and (iv) field emission scanning electron microscopy (FESEM). Results of photosynthetic activity and epifluorescence show no significant changes up to a dose of 1 kGy (helium ions), 2 kGy (iron ions), 5 kGy (X-rays) - the maximum doses applied for those radiation qualities - as well as a dose of 6 kGy of γ irradiation, which was the lowest dose applied for this low linear energy transfer (LET) radiation. Significant damage in a dose-related manner was observed only at much higher doses of γ irradiation (up to 113 kGy). These data corroborate the findings of the parallel STARLIFE studies on the effects of ionizing radiation on the lichen Circinaria gyrosa, its isolated photobiont, and the lichen Xanthoria elegans.

  19. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications.

    Science.gov (United States)

    Shwetha, Bondel; Ravikumar, Manickam; Supe, Sanjay S; Sathiyan, Saminathan; Lokesh, Vishwanath; Keshava, Subbarao L

    2012-01-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  20. Relationship between the exposure dose of high intensity focused ultrasound and the heated necrosis element

    Institute of Scientific and Technical Information of China (English)

    FENG Ruo; ZHANG Qiang; LI Faqi; ZHENG Xiaozheng; BAI Jin; XU Jianyi; WANG Yaojun; WANG Zhibiao

    2004-01-01

    Heated necrosis element of tissues is the basis for treating tumor by high intensity focused ultrasound (HIFU), so study on the relationship between the HIFU exposure dose and the heated necrosis element of tissues is of great significance for both HIFU clinical applications and basic research. Using Pennes and Rayleigh formulae the relationship between the exposure dose of an annular focused transducer and the heated necrosis element (I.e. Biological focused region) in a bovine liver in vitro at a depth of 2 cm is simulated in an exposure dose range with radiation sound intensity of 7000~25400 W/cm2 and exposure time of 0~20 s. The theoretical results appear to be in quite good agreement with the experimental ones. It is shown that on the basis of existing theories the heated necrosis element produced by HIFU exposure can be predicted. The deviation of the theory from the experiments under higher exposure dose has also been discussed.

  1. Experiences of high dose rate interstitial brachytherapy for carcinoma of the mobile tongue

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Hiroshi; Inoue, Toshihiko; Yamazaki, Hideya (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1994-03-01

    Interstitial brachytherapy was conducted for mobile tongue carcinoma using a high dose rate remote afterloading machine with small [sup 192]I source. Detailed method, named as 'linked double-botton technique', is to approach from submandibular skin by an open-ended stainless steel needles to the tongue lesion, and to replace each needle into flexible nylon tube from the oral cavity. Delivered dose was 60 Gy/10 Fr./5-6 days at the distance 5 mm from the source plane. Ten patients with mobile tongue carcinoma Tl-2N0 were treated with this method from October 1991 through August 1992. Local was uncontrolled in one patient, in whom the lesion was combined with leukoplakia at both lateral borders of the tongue. This was in accordance with the result in low dose rate treatment. This can be a substitute to low dose rate system for treatment of mobile tongue carcinoma. (author).

  2. Pulmonary edema following high intravenous doses of diatrizoate in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Maare, K.; Violante, M.; Zack, A.

    Serious adverse reactions to intravenous contrast media are rare but of major concern. Corticosteroids are the most commonly used drugs for prophylaxis but there is little documentation of their effectiveness. Controversy also exists about the optimum regime for these drugs. A rat model was used to evaluate the effect of methylprednisolone pretreatment for contrast media-induced pulmonary edema. Rats were given 40 mg methylprednisolone/kg intravenously at various time intervals before the intravenous injection of a high dose of diatrizoate (6 g I/kg). The combination of one dose of methylprednisolone at 24 hours plus another dose at 0.5 hours was the only regimen that caused a significant reduction in the degree of pulmonary edema induced by contrast media. This result provides support for the clinical regimen utilizing iterated doses of corticosteroids over a prolonged period of time. (orig.).

  3. Lack of high-dose radiation mediated prostate cancer promotion and low-dose radiation adaptive response in the TRAMP mouse model.

    Science.gov (United States)

    Lawrence, M D; Ormsby, R J; Blyth, B J; Bezak, E; England, G; Newman, M R; Tilley, W D; Sykes, P J

    2013-10-01

    Cancer of the prostate is a highly prevalent disease with a heterogeneous aetiology and prognosis. Current understanding of the biological mechanisms underlying the responses of prostate tissue to ionizing radiation exposure, including cancer induction, is surprisingly limited for both high- and low-dose exposures. As population exposure to radiation increases, largely through medical imaging, a better understanding of the response of the prostate to radiation exposure is required. Low-dose radiation-induced adaptive responses for increased cancer latency and decreased cancer frequency have been demonstrated in mouse models, largely for hematological cancers. This study examines the effects of high- and low-dose whole-body radiation exposure on prostate cancer development using an autochthonous mouse model of prostate cancer: TRansgenic Adenocarcinoma of the Mouse Prostate (TRAMP). TRAMP mice were exposed to single acute high (2 Gy), low (50 mGy) and repeated low (5 × 50 mGy) doses of X rays to evaluate both the potential prostate cancer promoting effects of high-dose radiation and low-dose adaptive response phenomena in this prostate cancer model. Prostate weights and histopathology were examined to evaluate gross changes in cancer development and, in mice exposed to a single 2 Gy dose, time to palpable tumor was examined. Proliferation (Ki-67), apoptosis, DNA damage (γ-H2AX) and transgene expression (large T-antigen) were examined within TRAMP prostate sections. Neither high- nor low-dose radiation-induced effects on prostate cancer progression were observed for any of the endpoints studied. Lack of observable effects of high- or low-dose radiation exposure suggests that modulation of tumorigenesis in the TRAMP model is largely resistant to such exposures. However, further study is required to better assess the effects of radiation exposure using alternative prostate cancer models that incorporate normal prostate and in those that are not driven by SV40 large T

  4. High-dose inhaled terbutaline increases muscle strength and enhances maximal sprint performance in trained men

    DEFF Research Database (Denmark)

    Hostrup, Morten; Kalsen, Anders; Bangsbo, Jens

    2014-01-01

    PURPOSE: The purpose of the present study was to investigate the effect of high-dose inhaled terbutaline on muscle strength, maximal sprinting, and time-trial performance in trained men. METHODS: Nine non-asthmatic males with a [Formula: see text] of 58.9 ± 3.1 ml min(-1) kg(-1) (mean ± SEM......) participated in a double-blinded randomized crossover study. After administration of inhaled terbutaline (30 × 0.5 mg) or placebo, subjects' maximal voluntary isometric contraction (MVC) of m.quadriceps was measured. After MVC, subjects performed a 30-s Wingate test. Sixty minutes following the Wingate test...... was not different between treatments (P = 0.236). CONCLUSION: High-dose inhaled terbutaline elicits a systemic response that enhances muscle strength and sprint performance. High-dose terbutaline should therefore continue to be restricted in competitive sport....

  5. Sustained effect after lowering high-dose infliximab in patients with rheumatoid arthritis: a prospective dose titration study.

    NARCIS (Netherlands)

    Bemt, B.J. van den; Broeder, AA den; Snijders, G.F.; Hekster, Y.A.; Riel, P.L.C.M. van; Benraad, B.; Wolbink, G.J.; Hoogen, F.H.J. van den

    2008-01-01

    OBJECTIVES: In clinical trials only a small subset of patients with rheumatoid arthritis (RA) benefits from higher than standard dose of infliximab (>3 mg/kg/8 weeks). However, dose escalation of infliximab is frequently applied in clinical practice. Individual adjustment of infliximab treatment

  6. Fundamental investigations of natural and laboratory generated SAR dose response curves for quartz OSL in the high dose range

    DEFF Research Database (Denmark)

    Timar-Gabor, Alida; Constantin, Daniela; Buylaert, Jan-Pieter;

    2015-01-01

    SAR-OSL investigations on quartz from Romanian loess resulted in non concordant fine and coarse-grain ages for equivalent doses higher than ~100 Gy. The laboratory dose response for both grain sizes is well represented by a sum of two saturating exponential functions, fine and coarse grains chara...

  7. High-temperature thermoluminescence of anion-deficient alumina and possibilities of its application in high-dose dosimetry

    Science.gov (United States)

    Surdo, A. I.; Milman, I. I.; Abashev, R. M.; Vlasov, M. I.

    2014-12-01

    Results of studies of the thermoluminescence (TL) of anion-deficient alumina (α-Al2O3 - δ) single crystals and based on them TLD-500 detectors exposed to pulsed X-ray and electron radiation in a wide range of doses D, pulsed dose rates P p , and temperatures are described. The TL responses of α-Al2O3 - δ for continuous and pulsed X-ray irradiation at D = 0.05-150 Gy are compared. Unlike continuous irradiation, in the case of pulsed irradiation at P p ≥ 6 × 106 Gy/s, a linear increase in the TL response as a function of D is registered in the main and "chromium" peaks at 450 and 580 K, respectively, with a decrease in the slope of the dose dependence at D > 2 Gy for the peak at 450 K. It is found that high-dose irradiation (>60 Gy) leads to the formation of a new TL peak at 830 K and the preferential redistribution of the stored light sums into this peak. The dose dependence for the TL peak at 830 K is studied. It is established that it is linear in a super-high dose range of 104 to 6 × 106 Gy at P p = 2.6 × 1011 Gy/s.

  8. Impact of high dose versus low dose atorvastatin on contrast induced nephropathy in diabetic patients with acute coronary syndrome undergoing early percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Haitham Galal

    2015-12-01

    Conclusion: No significant difference between high and low doses of atorvastatin in preventing CIN in diabetic patients with normal or mild renal impairment presenting with acute coronary syndrome who underwent early PCI.

  9. Efficacy of High-Dose Baclofen for Alcohol Use Disorder and Comorbid Bulimia: A Case Report.

    Science.gov (United States)

    Weibel, Sébastien; Lalanne, Laurence; Riegert, Myriam; Bertschy, Gilles

    2015-01-01

    High-dose baclofen is a promising treatment for alcohol use disorder, with a specific action on craving. A more general action on craving in other addictive disorders has been suggested based on the hypothesis of a common neurobiological pathway in addictions. We report the case of a woman with both alcohol use disorder and bulimia nervosa. There was a positive response to high-dose baclofen on alcohol craving, but no response on food craving. The case illustrates that craving could be differentially responsive to anti-craving drugs.

  10. High-dose intravenous IgG treatment and renal function.

    Science.gov (United States)

    Schifferli, J; Leski, M; Favre, H; Imbach, P; Nydegger, U; Davies, K

    1991-02-23

    In an open trial of high dose intravenous IgG (IVIG) treatment in nephrotic patients with glomerulonephritis, the first six patients so far studied showed a transient rise in plasma creatinine. This increase was not associated with any symptoms and the urinary deposit remained unchanged. Two other patients with pre-existing renal impairment but without nephrotic syndrome had a transient and reversible rise in plasma creatinine immediately after IVIG. These observations suggest that high-dose IVIG infusion can produce short-lived disturbances in renal function in patients with kidney diseases.

  11. Mucormycoses: serious complication of high-dose corticosteroid therapy for traumatic optic neuropathy.

    Science.gov (United States)

    Dojcinovic, I; Richter, M

    2008-04-01

    Mucormycosis is harmless to a healthy person, but can cause opportunistic infections in immunocompromised patients, and once it has invaded internal organs is frequently fatal. Traumatic optic neuropathy is a rare complication of maxillofacial trauma. Management is controversial, and there are no treatment guidelines in the literature. The main methods of treatment of this condition employed today are high-dose corticosteroids and surgical optic nerve decompression, either alone or in combination. In this case, the patient was in good health, but received high-dose corticosteroids for 2 weeks, which temporarily diminished immune response and permitted the development of mucormycosis.

  12. Dose response of multiple parameters for calyculin A-induced premature chromosome condensation in human peripheral blood lymphocytes exposed to high doses of cobalt-60 gamma-rays.

    Science.gov (United States)

    Lu, Xue; Zhao, Hua; Feng, Jiang-Bin; Zhao, Xiao-Tao; Chen, De-Qing; Liu, Qing-Jie

    2016-09-01

    Many studies have investigated exposure biomarkers for high dose radiation. However, no systematic study on which biomarkers can be used in dose estimation through premature chromosome condensation (PCC) analysis has been conducted. The present study aims to screen the high-dose radiation exposure indicator in calyculin A-induced PCC. The dose response of multiple biological endpoints, including G2/A-PCC (G2/M and M/A-PCC) index, PCC ring (PCC-R), ratio of the longest/shortest length (L/L ratio), and length and width ratio of the longest chromosome (L/B ratio), were investigated in calyculin A-induced G2/A-PCC spreads in human peripheral blood lymphocytes exposed to 0-20Gy (dose-rate of 1Gy/min) cobalt-60 gamma-rays. The G2/A-PCC index was decreased with enhanced absorbed doses of 4-20Gy gamma-rays. The G2/A PCC-R at 0-12Gy gamma-rays conformed to Poisson distribution. Three types of PCC-R were scored according to their shape and their solidity or hollowness. The frequencies of hollow PCC-R and PCC-R including or excluding solid ring in G2/A-PCC spreads were enhanced with increased doses. The length and width of the longest chromosome, as well as the length of the shortest chromosome in each G2/M-PCC or M/A-PCC spread, were measured. All L/L or L/B ratios in G2/M-PCC or M/A-PCC spread increased with enhanced doses. A blind test with two new irradiated doses was conducted to validate which biomarker could be used in dose estimation. Results showed that hollow PCC-R and PCC-R including solid ring can be utilized for accurate dose estimation, and that hollow PCC-R was optimal for practical application.

  13. Low or High Fractionation Dose {beta}-Radiotherapy for Pterygium? A Randomized Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Viani, Gustavo Arruda, E-mail: gusviani@gmail.com [Department of Radiation Oncology, Marilia Medicine School, Sao Paulo, SP (Brazil); De Fendi, Ligia Issa; Fonseca, Ellen Carrara [Department of Ophthalmology, Marilia Medicine School, Sao Paulo, SP (Brazil); Stefano, Eduardo Jose [Department of Radiation Oncology, Marilia Medicine School, Sao Paulo, SP (Brazil)

    2012-02-01

    Purpose: Postoperative adjuvant treatment using {beta}-radiotherapy (RT) is a proven technique for reducing the recurrence of pterygium. A randomized trial was conducted to determine whether a low fractionation dose of 2 Gy within 10 fractions would provide local control similar to that after a high fractionation dose of 5 Gy within 7 fractions for surgically resected pterygium. Methods: A randomized trial was conducted in 200 patients (216 pterygia) between February 2006 and July 2007. Only patients with fresh pterygium resected using a bare sclera method and given RT within 3 days were included. Postoperative RT was delivered using a strontium-90 eye applicator. The pterygia were randomly treated using either 5 Gy within 7 fractions (Group 1) or 2 Gy within 10 fractions (Group 2). The local control rate was calculated from the date of surgery. Results: Of the 216 pterygia included, 112 were allocated to Group 1 and 104 to Group 2. The 3-year local control rate for Groups 1 and 2 was 93.8% and 92.3%, respectively (p = .616). A statistically significant difference for cosmetic effect (p = .034), photophobia (p = .02), irritation (p = .001), and scleromalacia (p = .017) was noted in favor of Group 2. Conclusions: No better local control rate for postoperative pterygium was obtained using high-dose fractionation vs. low-dose fractionation. However, a low-dose fractionation schedule produced better cosmetic effects and resulted in fewer symptoms than high-dose fractionation. Moreover, pterygia can be safely treated in terms of local recurrence using RT schedules with a biologic effective dose of 24-52.5 Gy{sub 10.}.

  14. Efficacy and tolerability of high oral doses of levetiracetam in children with epilepsy.

    Science.gov (United States)

    Obeid, Makram; Pong, Amanda W

    2010-09-01

    Despite the advent of new antiepileptic drugs, many children continue to have refractory seizures. We sought to determine whether oral LEV is helpful in seizure control and tolerable at doses higher than 60mg/kg/day in the pediatric outpatient population. A retrospective chart review over a 1.5-year period was performed at the Columbia Comprehensive Epilepsy Center to identify children who were treated with levetiracetam doses titrated above the usual 40-60mg/kg/day. Data was collected on seizure semiology, epilepsy type, seizure frequency, concomitant antiepileptic drugs, and adverse effects. Thirty-two children, ranging in age from 1 to 19 years, required high dose levetiracetam. The median dosage of levetiracetam was 146mg/kg/day (range, 70-275mg/kg/day), and the median maximum serum trough level was 43mcg/ml (range, 20-121mcg/ml). All but one patient were taking one or more other antiepileptic drugs. A more than 50% reduction in seizure frequency was observed in 14 children (44%), with 5 achieving seizure freedom (16%). No response to high dose levetiracetam was found in 14 children (44%), and worsening of seizure frequency occurred in 4 (12%). Adverse effects were observed in 4 patients (12%), and were behavioral. Not only do some children tolerate high doses and serum levels of levetiracetam, but they may also benefit from them, suggesting that doses higher than 60mg/kg/day may be considered in children who partially respond to the lower doses. Copyright 2010 Elsevier B.V. All rights reserved.

  15. High-Dose versus Low-Dose Vitamin D Supplementation and Arterial Stiffness among Individuals with Prehypertension and Vitamin D Deficiency

    Directory of Open Access Journals (Sweden)

    Amanda Zaleski

    2015-01-01

    Full Text Available Introduction. Vitamin D deficiency is associated with the onset and progression of hypertension and cardiovascular disease (CVD. However, mechanisms underlying vitamin D deficiency-mediated increased risk of CVD remain unknown. We sought to examine the differential effect of high-dose versus low-dose vitamin D supplementation on markers of arterial stiffness among ~40 vitamin D deficient adults with prehypertension. Methods. Participants were randomized to high-dose (4000 IU/d versus low-dose (400 IU/d oral vitamin D3 for 6 months. 24 hr ambulatory blood pressure (BP, carotid-femoral pulse wave velocity, and pulse wave analyses were obtained at baseline and after 6 months of vitamin D supplementation. Results. There were no changes in resting BP or pulse wave velocity over 6 mo regardless of vitamin D dose (all p>0.202. High-dose vitamin D decreased augmentation index and pressure by 12.3 ± 5.3% (p=0.047 and 4.0 ± 1.5 mmHg (p=0.02, respectively. However, these decreases in arterial stiffness were not associated with increases in serum 25-hydroxyvitamin D over 6 mo (p=0.425. Conclusion. High-dose vitamin D supplementation appears to lower surrogate measures of arterial stiffness but not indices of central pulse wave velocity. Clinical Trial Registration. This trial is registered with www.clinicaltrials.gov (Unique Identifier: NCT01240512.

  16. Neutron dose measurements with the GSI ball at high-energy accelerators.

    Science.gov (United States)

    Fehrenbacher, G; Gutermuth, F; Kozlova, E; Radon, T; Schuetz, R

    2007-01-01

    A moderator-type neutron monitor containing pairs of TLD 600/700 elements (Harshaw) modified with the addition of a lead layer (GSI ball) for the measurement of the ambient dose equivalent from neutrons at medium- and high-energy accelerators, is introduced in this work. Measurements were performed with the Gesellschaft für Schwerionenforschung (GSI) ball as well as with conventional polyethylene (PE) spheres at the high-energy accelerator SPS at European Organization for Nuclear Research [CERN (CERF)] and in Cave A of the heavy-ion synchrotron SIS at GSI. The measured dose values are compared with dose values derived from calculated neutron spectra folded with dose conversion coefficients. The estimated reading of the spheres calculated by means of the response functions and the neutron spectra is also included in the comparison. The analysis of the measurements shows that the PE/Pb sphere gives an improved estimate on the ambient dose equivalent of the neutron radiation transmitted through shielding of medium- and high-energy accelerators.

  17. Myocardial protection induced by fentanyl in pigs exposed to high-dose adrenaline.

    Science.gov (United States)

    da Luz, Vinicius Fernando; Otsuki, Denise Aya; Gonzalez, Maria Margarita Castro; Negri, Elnara Marcia; Caldini, Elia Garcia; Damaceno-Rodrigues, Nilsa Regina; Malbouisson, Luiz Marcelo Sá; Viana, Bruno Gonçalves; Vane, Matheus Fachini; Carmona, Maria Jose Carvalho

    2015-10-01

    The use of high doses of adrenaline is common in critical patients, especially during cardiac arrest. During these situations, myocardial dysfunction can be a result of multiple factors, including adrenaline use. In addition, opioids have been shown to have anti-arrhythmic and anti-ischemic mechanisms that may confer cardiac protection. This study aimed to evaluate the effects of fentanyl on myocardial function in pigs exposed to high-dose adrenaline. After institutional ethics committee approval, 26 pigs were randomly allocated to receive either 20 μg/kg fentanyl (n = 10; fentanyl group) administered 5 min before five doses of adrenaline (20 μg/kg), equivalent-volume saline (n = 10; saline group) using the same adrenaline dosing protocol, or neither fentanyl nor adrenaline (n = 6; sham group). The fentanyl group showed lower levels of troponin at the end of the sixth hour compared with the saline group (1.91 ± 1.47 vs 5.44 ± 5.35 ng/mL, P = 0.019). Transmission electron microscopy and immunohistochemistry also showed less myocardial injury in the fentanyl group. The conclusion was reached that fentanyl attenuates myocardial injury caused by high-dose adrenaline without blunting the hemodynamic effect of adrenaline.

  18. Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy.

    Science.gov (United States)

    Candela-Juan, Cristian; Granero, Domingo; Vijande, Javier; Ballester, Facundo; Perez-Calatayud, Jose; Rivard, Mark J

    2014-06-01

    In surface and interstitial high-dose-rate brachytherapy with either (60)Co, (192)Ir, or (169)Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields. Results were corrected to account for a realistic clinical case with multiple dwell positions. The range of the high backscatter dose enhancement in water is 3 mm for (60)Co and 1 mm for both (192)Ir and (169)Yb. Transmission data for (60)Co and (192)Ir are smaller than those reported by Papagiannis et al (2008 Med. Phys. 35 4898-4906) for brachytherapy facility shielding; for (169)Yb, the difference is negligible. In conclusion, the backscatter overdose produced by the lead shield can be avoided by just adding a few millimetres of bolus. Transmission data provided in this work as a function of lead thickness can be used to estimate healthy organ equivalent dose saving. Use of a lead shield is justified.

  19. Effects of high-dose ethanol intoxication and hangover on cognitive flexibility.

    Science.gov (United States)

    Wolff, Nicole; Gussek, Philipp; Stock, Ann-Kathrin; Beste, Christian

    2016-10-27

    The effects of high-dose ethanol intoxication on cognitive flexibility processes are not well understood, and processes related to hangover after intoxication have remained even more elusive. Similarly, it is unknown in how far the complexity of cognitive flexibility processes is affected by intoxication and hangover effects. We performed a neurophysiological study applying high density electroencephalography (EEG) recording to analyze event-related potentials (ERPs) and perform source localization in a task switching paradigm which varied the complexity of task switching by means of memory demands. The results show that high-dose ethanol intoxication only affects task switching (i.e. cognitive flexibility processes) when memory processes are required to control task switching mechanisms, suggesting that even high doses of ethanol compromise cognitive processes when they are highly demanding. The EEG and source localization data show that these effects unfold by modulating response selection processes in the anterior cingulate cortex. Perceptual and attentional selection processes as well as working memory processes were only unspecifically modulated. In all subprocesses examined, there were no differences between the sober and hangover states, thus suggesting a fast recovery of cognitive flexibility after high-dose ethanol intoxication. We assume that the gamma-aminobutyric acid (GABAergic) system accounts for the observed effects, while they can hardly be explained by the dopaminergic system. © 2016 Society for the Study of Addiction.

  20. High-dose metoclopramide + lorazepam versus low-dose metoclopramide + lorazepam + dehydrobenzperidol in the treatment of cisplatin-induced nausea and vomiting

    DEFF Research Database (Denmark)

    Herrstedt, Jørn; Hannibal, J; Hallas, Jesper;

    1991-01-01

    In a randomized double-blind, cross-over trial of 34 patients receiving cisplatin-based chemotherapy (20-100 mg/m2), the antiemetic effect of high-dose metoclopramide (HDM) (10 mg/kg iv. loading dose + 7 hours continuous infusion) + lorazepam (L) (2.5 mg x 4 po) was compared with low.......01). Sedation was seen in all but 1 patient, and was graded as severe in 6 patients receiving the HDM and in 2 patients receiving the LDM regimen. No extrapyramidal adverse reactions were seen. We conclude that high-dose metoclopramide + lorazepam is a safe antiemetic regimen and significantly superior to low...

  1. Possible use of EPDM in radioactive waste disposal: Long term low dose rate and short term high dose rate irradiation in aquatic and atmospheric environment

    Science.gov (United States)

    Hacıoğlu, Fırat; Özdemir, Tonguç; Çavdar, Seda; Usanmaz, Ali

    2013-02-01

    In this study, changes in the properties of ethylene propylene diene terpolymer (EPDM) irradiated with different dose rates in ambient atmosphere and aqueous environment were investigated. Irradiations were carried out both with low dose and high dose rate irradiation sources. EPDM samples which were differentiated from each other by peroxide type and 5-ethylidene 2-norbornene (ENB) contents were used. Long term low dose rate irradiations were carried out for the duration of up to 2.5 years (total dose of 1178 kGy) in two different irradiation environments. Dose rates (both high and low), irradiation environments (in aquatic and open to atmosphere), and peroxide types (aliphatic or aromatic) were the parameters studied. Characterization of irradiated EPDM samples were performed by hardness, compression, tensile, dynamic mechanical analysis (DMA), TGA-FTIR, ATR-FTIR, XRD and SEM tests. It was observed that the irradiation in water environment led to a lower degree of degradation when compared to that of irradiation open to atmosphere for the same irradiation dose. In addition, irradiation environment, peroxide type and dose rate had effects on the extent of change in the properties of EPDM. It was observed that EPDM is relatively radiation resistant and a candidate polymer for usage in radioactive waste management.

  2. Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source

    Directory of Open Access Journals (Sweden)

    Barlanka Ravikumar

    2012-01-01

    Full Text Available In Brachytherapy treatment planning, the effects of tissue heterogeneities are commonly neglected due to lack of accurate, general and fast three-dimensional (3D dose-computational algorithms. In performing dose calculations, it is assumed that the tumor and surrounding tissues constitute a uniform, homogeneous medium equivalent to water. In the recent past, three-dimensional computed tomography (3D-CT based treatment planning for Brachytherapy applications has been popularly adopted. However, most of the current commercially available planning systems do not provide the heterogeneity corrections for Brachytherapy dosimetry. In the present study, we have measured and quantified the impact of inhomogeneity caused by different tissues with a 0.015 cc ion chamber. Measurements were carried out in wax phantom which was employed to measure the heterogeneity. Iridium-192 (192 Ir source from high dose rate (HDR Brachytherapy machine was used as the radiation source. The reduction of dose due to tissue inhomogeneity was measured as the ratio of dose measured with different types of inhomogeneity (bone, spleen, liver, muscle and lung to dose measured with homogeneous medium for different distances. It was observed that different tissues attenuate differently, with bone tissue showing maximum attenuation value and lung tissue resulting minimum value and rest of the tissues giving values lying in between those of bone and lung. It was also found that inhomogeneity at short distance is considerably more than that at larger distances.

  3. EPR and UV spectroscopic study of table sugar as a high-dose dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Yordanov, N.D. E-mail: ndyepr@bas.bg; Gancheva, V.; Georgieva, E

    2002-10-01

    The possibilities for the estimation of the absorbed dose for high-energy radiation with a new self-calibrated dosimeter containing table sugar as a radiation-sensitive material and Mn{sup 2+}/MgO as an internal standard by the method of electron paramagnetic resonance (EPR) is reported. The dose response of this dosimeter is represented as the ratio between the EPR signal intensities of sugar and Mn{sup 2+} versus absorbed dose. Because the EPR spectra of both substances are simultaneously recorded, the influence of some related instrumental setting parameters were investigated. UV spectral studies on water solutions of irradiated solid sugar were also performed. In all solutions of irradiated sugar samples a band at 267 nm was recorded as linearly increasing intensity with the absorbed dose. The minimum detectable dose using the UV spectrum of water solutions of irradiated sugar is 100 Gy. Combination of EPR and UV spectral data is possible to use for independent internal or international calibration and control of dose estimations.

  4. Influence of prophylactic anticonvulsant therapy on high-dose busulphan kinetics.

    Science.gov (United States)

    Hassan, M; Oberg, G; Björkholm, M; Wallin, I; Lindgren, M

    1993-01-01

    The pharmacokinetics of high-dose busulphan was studied in 17 patients during conditioning prior to bone marrow transplantation using deuterium-labeled busulphan (d8-BU). About 50% of busulphan doses 1 and 16 was replaced with d8-BU. Patients were treated with phenytoin or diazepam as prophylactic anticonvulsant therapy. Patients who received phenytoin demonstrated significantly higher clearance (mean +/- SD, 3.32 +/- 0.99 ml min-1 kg-1), a lower area under the concentration-time curve (AUC, 5,412 +/- 1,534 ng h ml-1; corrected for dose/kilogram) and a shorter elimination half-life (3.03 +/- 0.57 h) for the last dose of d8-BU (dose 16) as compared with the first dose (2.80 +/- 0.78 ml min-1 kg-1, 6,475 +/- 2,223 ng h ml-1 and 3.94 +/- 1.10 h, respectively). No difference in the above mentioned pharmacokinetic parameters was seen in patients treated with diazepam. Moreover, a continuous decrease in the steady-state level of busulphan was observed in four of seven patients in the phenytoin-treated group, whereas in the diazepam group, such a decrease was seen in only one of eight patients. We conclude that phenytoin used as prophylactic anticonvulsant therapy alters busulphan pharmacokinetics and, most probably, its pharmacodynamics. For adequate prophylactic therapy, anticonvulsants with fewer enzyme-inductive properties than phenytoin should be used.

  5. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo; Granero, Domingo; Perez-Calatayud, Jose; Melhus, Christopher S.; Rivard, Mark J. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, C/Dr. Moliner 50, E-46100 Burjassot (Spain) and IFIC, CSIC-University of Valencia, C/Dr. Moliner 50, E-46100 Burjassot (Spain); Department of Radiation Physics, ERESA, Hospital General Universitario, Avenida Tres Cruces, 2, E-46014 Valencia (Spain); Department of Radiation Oncology, La Fe University Hospital, Avenida Campanar 21, E-46009 Valencia (Spain); Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2009-09-15

    Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

  6. Advances in the vaccination of the elderly against influenza: role of a high-dose vaccine.

    Science.gov (United States)

    Sullivan, Seth J; Jacobson, Robert; Poland, Gregory A

    2010-10-01

    On 23 December 2009, the US FDA approved Fluzone® High Dose, a high-dose formulation of the trivalent inactivated influenza vaccine, for prevention of influenza in people 65 years of age and older. As it was approved via an accelerated process designed to allow expeditious availability of safe and effective products with promise to treat or prevent serious or life-threatening diseases, the manufacturer is required to conduct further studies to demonstrate effectiveness. Although these studies are underway, a recently completed randomized, controlled trial demonstrated that this vaccine, containing four-times more hemagglutinin than standard-dose inactivated influenza vaccines, can produce an enhanced immunologic response in subjects of 65 years of age and older, while maintaining a favorable safety profile. This article introduces the vaccine, presents currently available safety and immunogenicity data, discusses current recommendations for use, and proposes what we can expect in the coming years.

  7. High doses of dextromethorphan, an NMDA antagonist, produce effects similar to classic hallucinogens

    Science.gov (United States)

    Carter, Lawrence P.; Johnson, Matthew W.; Mintzer, Miriam Z.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2013-01-01

    Rationale Although reports of dextromethorphan (DXM) abuse have increased recently, few studies have examined the effects of high doses of DXM. Objective This study in humans evaluated the effects of supratherapeutic doses of DXM and triazolam. Methods Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg/70kg), and placebo were administered to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Subjective, behavioral, and physiological effects were assessed repeatedly after drug administration for 6 hours. Results Triazolam produced dose-related increases in subject-rated sedation, observer-rated sedation, and behavioral impairment. DXM produced a profile of dose-related physiological and subjective effects differing from triazolam. DXM effects included increases in blood pressure, heart rate, and emesis, increases in observer-rated effects typical of classic hallucinogens (e.g. distance from reality, visual effects with eyes open and closed, joy, anxiety), and participant ratings of stimulation (e.g. jittery, nervous), somatic effects (e.g. tingling, headache), perceptual changes, end-of-session drug liking, and mystical-type experience. After 400 mg/70kg DXM, 11 of 12 participants indicated on a pharmacological class questionnaire that they thought they had received a classic hallucinogen (e.g. psilocybin). Drug effects resolved without significant adverse effects by the end of the session. In a 1-month follow up volunteers attributed increased spirituality and positive changes in attitudes, moods, and behavior to the session experiences. Conclusions High doses of DXM produced effects distinct from triazolam and had characteristics that were similar to the classic hallucinogen psilocybin. PMID:22526529

  8. High Dose Astaxanthin Lowers Blood Pressure and Increases Insulin Sensitivity in Rats: Are These Effects Interdependent?

    Directory of Open Access Journals (Sweden)

    Harry G. Preuss, Bobby Echard, Eiji Yamashita, Nicholas V. Perricone

    2011-01-01

    Full Text Available The present investigation in Sprague-Dawley rats (SD was designed to examine effects of astaxanthin (Asta at different doses on elevated blood pressure (BP and glucose-insulin perturbations produced by heavy sucrose ingestion. We also examined effects of Asta on BP during restraint stress. SD were divided into six groups each containing eight rats. All SD ate a basic diet of ground regular rat chow with sucrose added at 30% w/w. The Control group received only the basic diet containing added sucrose, while the other five groups each received the same diet with added test material: captopril, (30 mg/Kg, pioglitazone (15.0 mg/Kg, low Asta (25 mg/Kg, medium Asta (50 mg/kg or high Asta (100 mg/Kg. Many tests were carried out to examine the mechanisms behind the effects of Asta on BP (serum ACE activity, losartan challenge, and LNAME challenge and the glucose-insulin system (glucose tolerance, HOMA measurement, and insulin challenge. In SD, a relatively low dose of Asta decreased SBP, but produced no major changes in the glucose-insulin system simulating results from a previous study using Zucker Fatty Rats. Increasing the dose of Asta resulted in both a lowering of elevated systolic BP and enhanced insulin sensitivity determined by many different estimations. BP lowering was consistent with changes in the renin-angiotensin (RAS and nitric oxide (NO systems. At the examined doses of each, captopril lowered BP in SD without influencing glucose-insulin metabolism, whereas pioglitazone favorably affected glucose-insulin metabolism while showing essentially no effects on BP. Accordingly, Asta beneficially affects both sucrose-induced elevations of BP and insulin resistance at relatively high doses in SD. Also, Asta at higher doses lessens restraint stress, whereas, captopril and pioglitazone did not at the doses examined, even though they influenced the BP and glucose-insulin systems respectively.

  9. A study of high-dose lenalidomide induction and low-dose lenalidomide maintenance therapy for patients with hypomethylating agent refractory myelodysplastic syndrome.

    Science.gov (United States)

    Cherian, Mathew A; Tibes, Raoul; Gao, Feng; Fletcher, Theresa; Fiala, Mark; Uy, Geoffrey L; Westervelt, Peter; Jacoby, Meagan A; Cashen, Amanda F; Stockerl-Goldstein, Keith; DiPersio, John F; Vij, Ravi

    2016-11-01

    Myelodysplastic syndromes (MDS) are clonal hematopoietic disorders characterized by bone marrow failure which frequently progress to acute myeloid leukemia. Patients who fail to respond to, or progress on first-line DNA hypomethylating agents (HMA) have a poor prognosis. Conventionally dosed lenalidomide has activity in 5q-MDS. In other subtypes, it may reduce RBC transfusion requirements but does not result in cytogenetic responses. We previously reported that high-dose lenalidomide induction (50 mg/day) results in complete remissions in a high fraction of patients. We, therefore, conducted a Phase 2 trial of the same regimen in MDS refractory to HMA. Marrow complete remissions were seen in 33% of patients and hematological improvement in 8% of patients. Significant infections complicated more than 50% of cases. Future trials to explore alternative dosing schedules of high-dose lenalidomide to increase efficacy while decreasing toxicity are warranted.

  10. The high-dose and high-temperature monitors of reactor irradiation based on insulators

    Directory of Open Access Journals (Sweden)

    V.A. Stepanov

    2015-10-01

    It has been experimentally shown that the use of Al2O3 single crystals and BN ceramics provides means of monitoring the temperature of irradiation from 370 to 1900 K. The temperature is derived from measurements of the optical absorption or X-ray diffraction line shifts after post-radiation annealing of the monitors. We discuss the applicability of (a the optical absorption and F-center luminescence spectroscopies of irradiated Al2O3 single crystals for gamma dose evaluation and (b the isotopic analysis of irradiated BN ceramics for neutron dose evaluation.

  11. The impact of low-Z and high-Z metal implants in IMRT: A Monte Carlo study of dose inaccuracies in commercial dose algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Spadea, Maria Francesca, E-mail: mfspadea@unicz.it [Department of Experimental and Clinical Medicine, University of Magna Graecia, Catanzaro 88100, Italy and Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States); Verburg, Joost Mathias; Seco, Joao [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States); Baroni, Guido [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano University, Milano 20133, Italy and Bioengineering Unit, Fondazione CNAO, Pavia 27100 (Italy)

    2014-01-15

    Purpose: The aim of the study was to evaluate the dosimetric impact of low-Z and high-Z metallic implants on IMRT plans. Methods: Computed tomography (CT) scans of three patients were analyzed to study effects due to the presence of Titanium (low-Z), Platinum and Gold (high-Z) inserts. To eliminate artifacts in CT images, a sinogram-based metal artifact reduction algorithm was applied. IMRT dose calculations were performed on both the uncorrected and corrected images using a commercial planning system (convolution/superposition algorithm) and an in-house Monte Carlo platform. Dose differences between uncorrected and corrected datasets were computed and analyzed using gamma index (Pγ{sub <1}) and setting 2 mm and 2% as distance to agreement and dose difference criteria, respectively. Beam specific depth dose profiles across the metal were also examined. Results: Dose discrepancies between corrected and uncorrected datasets were not significant for low-Z material. High-Z materials caused under-dosage of 20%–25% in the region surrounding the metal and over dosage of 10%–15% downstream of the hardware. Gamma index test yielded Pγ{sub <1}>99% for all low-Z cases; while for high-Z cases it returned 91% < Pγ{sub <1}< 99%. Analysis of the depth dose curve of a single beam for low-Z cases revealed that, although the dose attenuation is altered inside the metal, it does not differ downstream of the insert. However, for high-Z metal implants the dose is increased up to 10%–12% around the insert. In addition, Monte Carlo method was more sensitive to the presence of metal inserts than superposition/convolution algorithm. Conclusions: The reduction in terms of dose of metal artifacts in CT images is relevant for high-Z implants. In this case, dose distribution should be calculated using Monte Carlo algorithms, given their superior accuracy in dose modeling in and around the metal. In addition, the knowledge of the composition of metal inserts improves the accuracy of

  12. The impact of body mass index on rectal dose in locally advanced cervical cancer treated with high-dose-rate brachytherapy.

    Science.gov (United States)

    Lim, Jihoon; Durbin-Johnson, Blythe; Valicenti, Richard; Mathai, Matthew; Stern, Robin L; Mayadev, Jyoti

    2013-01-01

    The impact of body mass index (BMI) on rectal dose in brachytherapy for cervical cancer is unknown. We assessed the association of BMI on rectal dose and lower gastrointestinal (GI) toxicity. Between 2007 and 2010, 51 patients with 97 brachytherapy planning images were reviewed. Volumetric measurements of the maximum percentage, mean percentage, dose to 2cc (D2cc), and dose to 1cc (D1cc) of the rectum, and the Internal Commission on Radiation Units and Measurement (ICRU) rectal point were recorded. Linear mixed effect models, analysis of variance, and regression analyses were used to determine the correlation between multiple observations or to detect a difference in the mean. The GI acute and late toxicity were prospectively recorded and retrospectively analyzed. The average BMI (kg/m(2)) was 27.7 with a range of 17.4-46.6. Among the patients, 8% were morbidly obese, 25% obese, 25% overweight, 40% normal weight, and 2% underweight. The mean D1cc, D2cc, mean rectal dose (%), maximum rectal dose (%), and ICRU rectum was 3.03 Gy, 2.78 Gy, 20%, 60%, and 2.99 Gy, respectively. On multivariate analysis, there was a significant decrease in the D1cc and D2cc rectal dose (p=0.016), ICRU rectal point dose (p=0.022), and mean rectal dose percentage (p=0.021) with an increase in BMI. There was, however, no statistically significant relationship between BMI and GI toxicity. Obesity decreases the rectal dose given in high-dose-rate brachytherapy for locally advanced cervical cancer because of an increase in fatty tissue in the recto-uterine space. There is no significant correlation between BMI and acute or late GI toxicity. Published by Elsevier Inc.

  13. HIGH AND LOW DOSE IVIG THERAPY IN GUILLAIN-BARRE SYNDROME CHILDREN: A COMPARISON

    Directory of Open Access Journals (Sweden)

    P. KARIMZADEH

    2006-06-01

    Full Text Available Introduction:Acute inflammatory demyelinating peripheral neuropathy (GuillainBarre-Syndrome is by far the most common cause of immune-medicatedperipheral nervous system disease in children; with the near disappearanceof poliomyelitis, GBS is responsible for the great majority of cases ofacute flaccid paralysis. So far, in several controlled studies, corticosteroids,plasmapheresis and IVIG have been utilized in pediatric patients, afflictedwith GBS. Regarding IVIG therapy, two methods have been used; thehigh dose (1 gr/kg/day for 2 days, and the low dose (400mg/kg/day for5 days. Review of literature shows that a faster rate of recovery can beaccomplished in patients who receive total dose of IVIG in 2 days ascompared to the dose being given over 5 days.Materials & Methods: In this study we have compared these two types of treatment in aninvestigation, conducted in the Mofid Children Hospital on pediatricpatients who had sudden onset of acute flaccid paralysis, and werediagnosed as having GBS. Based on histories, physical examination andelectrodiagnosis, subjects were divided in two groups, the high doseIVIG treatment, 1gr/kg/day for 2 days (experimental group, and the lowdose IVIG treatment, 400 mg/kg/day for 5 days (control group. Statisticalanalyses were then carried out using the appropriate software.Results: Result of this study showed a faster rate of recovery for patients in thehigh dose IVIG group; in this group duration of weakness of limbs wasshorter and returning of DTR was faster than in controls. In fact, in thistype of treatment, the relationship between high dose IVIG therapy anddrug side effects was not significant.Conclusion: Base upon the finding in the present study, we conclude that the highdose IVIG therapy is superior to low dose, in view of faster duration ofrecovery and shorter hospital stay.Also we may infer that shorter hospital stay could be a factor in reducingof more nasocomial infection.In conclusion, we suggest using

  14. Trichoderma species fungemia after high-dose chemotherapy and autologous stem cell transplantation: a case report.

    Science.gov (United States)

    Festuccia, M; Giaccone, L; Gay, F; Brunello, L; Maffini, E; Ferrando, F; Talamo, E; Boccadoro, M; Serra, R; Barbui, A; Bruno, B

    2014-08-01

    We present a case of Trichoderma fungemia with pulmonary involvement in a multiple myeloma patient, who was severely immunocompromised and heavily treated with high-dose melphalan, and underwent autologous hematopoietic cell transplantation. This is the first report, to our knowledge, of proven Trichoderma fungemia, defined by published criteria, successfully treated with voriconazole.

  15. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids

    DEFF Research Database (Denmark)

    Jiang, Ping; Baumann, René; Dunst, Juergen;

    2016-01-01

    PURPOSE: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. METHODS AND MATERIALS: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immed...

  16. Daily high doses of fluoxetine for weight loss and improvement in lifestyle before bariatric surgery

    NARCIS (Netherlands)

    Dolfing, JG; Wolffenbuttel, BHR; Oei, HI; ten Hoor-Aukerna, NM; Schweitzer, DH

    2005-01-01

    Background: The number of gastric restrictive bariatric operations is increasing each year, but about one-fifth of patients will become disappointed due to unsatisfactory weight reduction or annoying complications. We questioned whether weight reduction by taking high doses of fluoxetine improves li

  17. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    NARCIS (Netherlands)

    Borot, Maxence; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-01-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance.

  18. Hemolytic anemia following high dose intravenous immunoglobulin in patients with chronic neurological disorders

    DEFF Research Database (Denmark)

    Markvardsen, L H; Christiansen, Ingelise; Harbo, T

    2014-01-01

    High dose intravenous immunoglobulin (IVIG) is an established treatment for various neuromuscular disorders. Recently, cases of hemolytic anemia following IVIG have been observed. The objective of this study was to determine the extent of anemia and hemolysis after IVIG and its relationship...

  19. Monitoring performance of the cameras under the high dose-rate gamma ray environments.

    Science.gov (United States)

    Cho, Jai Wan; Choi, Young Soo; Jeong, Kyung Min

    2014-05-01

    CCD/CMOS cameras, loaded on a robot system, are generally used as the eye of the robot and monitoring unit. A major problem that arises when dealing with images provided by CCD/CMOS cameras under severe accident situations of a nuclear power plant is the presence of speckles owing to the high dose-rate gamma irradiation fields. To use a CCD/CMOS camera as a monitoring unit in a high radiation area, the legibility of the camera image in such intense gamma-radiation fields should therefore be defined. In this paper, the authors describe the monitoring index as a figure of merit of the camera's legibleness under a high dose-rate gamma ray irradiation environment. From a low dose-rate (10 Gy h) to a high dose-rate (200 Gy h) level, the legible performances of the cameras owing to the speckles are evaluated. The numbers of speckles generated by gamma ray irradiation in the camera image are calculated by an image processing technique. The legibility of the sensor indicator (thermo/hygrometer) owing to the number of speckles is also presented.

  20. Cytoprotective responses in HaCaT keratinocytes exposed to high doses of curcumin

    NARCIS (Netherlands)

    Lundvig, D.M.S.; Pennings, S.W.C.; Brouwer, K.M.; Mtaya-Mlangwa, M.; Mugonzibwa, E.; Kuijpers-Jagtman, A.M.; Wagener, F.A.D.T.G.; Hoff, J.W. Von den

    2015-01-01

    Wound healing is a complex process that involves the well-coordinated interactions of different cell types. Topical application of high doses of curcumin, a plant-derived polyphenol, enhances both normal and diabetic cutaneous wound healing in rodents. For optimal tissue repair interactions between

  1. High-dose anti-histamine use and risk factors in children with urticaria

    Science.gov (United States)

    Uysal, Pınar; Avcil, Sibelnur; Erge, Duygu

    2016-01-01

    Aim The drugs of choice in the treatment of urticaria in children are H1-antihistamines. The aim of the study was to evaluate children with urticaria and define risk factors for requirement of high-dose H1-antihistamines in children with urticaria. Material and Methods The medical data of children who were diagnosed as having urticaria admitted to our outpatient clinic between January 2014 and January 2016 were searched. The medical histories, concomitant atopic diseases, parental atopy histories, medications, treatment responses, blood eosinophil and basophil counts, and serum total IgE levels were recorded. In addition, the urticaria activity score for seven days, autoimmune antibody tests, and skin prick test results were evaluated in children with chronic urticaria. Results The numbers of the children with acute and chronic urticaria were 138 and 92, respectively. The age of the children with chronic urticaria was higher than that of those with acute urticaria (p0.05). There was a negative correlation between blood eosinophil count and the UAS7 score in children with chronic urticaria (r=−0.276, p=0.011). Chronic urticaria and requirement of high dose H1-antihistamines were significant in children aged ≥10 years (purticaria. Conclusion The requirement of high-dose H1-antihistamines was higher with children’s increasing age. Disease severity and basopenia were risk factors for the requirement of high-dose H1-antihistamines. PMID:28123332

  2. Cytoprotective responses in HaCaT keratinocytes exposed to high doses of curcumin

    NARCIS (Netherlands)

    Lundvig, D.M.S.; Pennings, S.W.C.; Brouwer, K.M.; Mtaya-Mlangwa, M.; Mugonzibwa, E.; Kuijpers-Jagtman, A.M.; Wagener, F.A.D.T.G.; Hoff, J.W. Von den

    2015-01-01

    Wound healing is a complex process that involves the well-coordinated interactions of different cell types. Topical application of high doses of curcumin, a plant-derived polyphenol, enhances both normal and diabetic cutaneous wound healing in rodents. For optimal tissue repair interactions between

  3. Rat adipose tissue rapidly accumulates and slowly releases an orally-administered high vitamin D dose

    NARCIS (Netherlands)

    Brouwer, DAJ; van Beek, J; Ferwerda, H; Brugman, AM; van der Klis, FRM; Muskiet, FAJ

    1998-01-01

    We investigated the effect of oral high-dose cholecalciferol on plasma and adipose tissue cholecalciferol and its subsequent release, and on plasma 25-hydroxyvitamin D (25(OH)D). Female Wistar rats (n 126) received 37.5 mu g cholecalciferol/d for 14 d and were subsequently studied for a further 88 d

  4. Irreversible neurological worsening following high-dose corticosteroids in advanced progressive multiple sclerosis

    NARCIS (Netherlands)

    Koch, M; De Keyser, J

    2006-01-01

    Background: A course of high-dose corticosteroids has been shown to hasten recovery from a relapse of multiple sclerosis (MS). Some patients with progressive MS ask for a course with corticosteroids outside a relapse, hoping to gain some functional improvement. Objective: To describe 4 patients with

  5. Pregnancy outcomes following the administration of high doses of dexamethasone in early pregnancy.

    Science.gov (United States)

    Namdar Ahmadabad, Hasan; Kayvan Jafari, Sabah; Nezafat Firizi, Maryam; Abbaspour, Ali Reza; Ghafoori Gharib, Fahime; Ghobadi, Yusef; Gholizadeh, Samira

    2016-03-01

    In the present study, we aimed to evaluate the effects of high doses of dexamethasone (DEX) in early pregnancy on pregnancy outcomes. Pregnant BALB/c mice were treated with high-dose DEX in the experimental group or saline in the control group on gestational days (GDs) 0.5 to 4.5. Pregnant mice were sacrificed on GDs 7.5, 13.5, or 18.5 and their peripheral blood, placentas, fetuses, and uterine tissue were collected. Decidual and placenta cell supernatants were examined to evaluate the effect of DEX on the proliferation of mononuclear cells, the quantity of uterine macrophages and uterine natural killer (uNK) cells, and levels of progesterone and 17β-estradiol, as determined by an 3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyltetrazolium bromide assay, immunohistochemistry, and enzyme-linked immunosorbent assay, respectively. We also were measured fetal and placental growth parameters on GD 18.5. We found that high doses of DEX were associated with an increased abortion rate, enhancement of the immunosuppressive effect of the decidua, alterations in placental growth parameters, decreased progesterone and 17β-estradiol levels, and a reduced frequency of macrophages and uNK cells. Our data suggest that the high-dose administration of DEX during early pregnancy negatively affected pregnancy outcomes.

  6. Treatment failure of a single high dose of ivermectin for Mansonella perstans filariasis.

    Science.gov (United States)

    Van den Enden, E; Van Gompel, A; Van der Stuyft, P; Vervoort, T; Van den Ende, J

    1993-01-01

    Infections with Mansonella perstans are common in certain parts of Africa and South America. There is no standard treatment at present. We evaluated the effect of a single high dose of ivermectin (600 micrograms/kg) on microfilaraemia in 7 consecutive patients. No decrease in microfilarial counts could be demonstrated after a follow-up period of 7-56 d.

  7. Value of recombinant human thyrotropin in high-dose radioiodine therapy: a case report.

    Science.gov (United States)

    Müller, Vika; Bohuslavizki, Karl H; Klutmann, Susanne; Clausen, Malte

    2002-12-01

    We report on a high-dose radioiodine therapy after injection of recombinant human thyrotropin (rhTSH) in a 61-y-old woman with compression of the spinal cord caused by metastasis of a follicular thyroid carcinoma. Fourteen years ago, the patient underwent subtotal thyroidectomy because of multinodular goiter without any histologic evidence for malignant disease, and the patient was put on thyroxine substitution (100 micro g/d). In April 2000, she developed paralysis of the right leg. Morphologic imaging revealed spinal compression caused by a space-occupying lesion within the thoracic spine. Subsequent biopsy and histology demonstrated metastasis of a follicular thyroid carcinoma. Therefore, high-dose radioiodine therapy was scheduled after 4 wk of hormone withdrawal. Within a few days of being off thyroxine, the patient's paralytic symptoms worsened rapidly. The patient was again put on thyroxine, 100 micro g/d, and high-dose radioiodine therapy under stimulation with rhTSH was performed without any side effects. The second high-dose radioiodine therapy 3 mo later, again performed under stimulation with rhTSH, showed significantly less iodine avidity, and thyroglobulin levels fell from 1,024 micro g/L to 361 micro g/L, thereby demonstrating therapeutic efficacy. Thus, rhTSH might be used as a tool not only in the diagnostic application but also in the therapeutic application of (131)I.

  8. Severe encephalopathy after high-dose chemotherapy with autologous stem cell support for brain tumours.

    NARCIS (Netherlands)

    Berkmortel, F. van den; Gidding, C.E.M.; Kanter, M. De; Punt, C.J.A.

    2006-01-01

    Recurrent medulloblastoma carries a poor prognosis. Long-term survival has been obtained with high-dose chemotherapy with autologous stem cell transplantation and secondary irradiation. A 21-year-old woman with recurrent medulloblastoma after previous chemotherapy and radiotherapy is presented. The

  9. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    Directory of Open Access Journals (Sweden)

    Mihir Kothari

    2014-01-01

    Full Text Available Part time occlusion therapy is not reported to cause occlusion (reverse amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  10. Axillary block duration and related hemodynamic changes: high versus low dose Adrenaline addition to Lidocaine

    Directory of Open Access Journals (Sweden)

    Shariat Moharari R

    2009-03-01

    Full Text Available "nBackground: Axillary block is used for inducing anesthesia in outpatient hand and forearm surgeries. Few researches have studied hemodynamic and blockade effects of low doses of Epinephrine. The aim of the present study was to compare the duration of analgesia and hemodynamic changes following the injection of high/low epinephrine doses in such surgeries. "nMethods: The present randomized clinical trial study was conducted on healthy individuals (ASA I-II who were candidates for hand and forearm surgeries. The patients were randomly divided into three groups. The first two groups were allocated to receive lidocaine with low (0.6µg/cc and high (5µg/cc doses of epinephrine whereas lidocaine plus normal saline was injected in the third group. The hemodynamic changes (Mean arterial blood pressure and heart rate and the occurance of any side-effects along with the duration of analgesia and motor block were recorded. "nResults: From among the total of 75 patients, 15 cases were excluded due to incomplete blockade or failure needing general anesthesia. The duration of analgesia and the motor block were longer in the high dose epinephrine group, the difference, however, was not statistically significant. Heart rate changes within the groups was significant in the 4th-7th and 10th minutes. Mean arterial blood pressure changes was only significant in the 4th minute, within the groups. "nConclusions: Administering low doses of epinephrine plus lidocaine as a local anesthetic not only provides acceptable analgesia compared to higher doses of the medication, but also is associated with fewer side effects.

  11. MINERALIZATION STUDY OF RENAL RATS FOLLOWING OVARYOHYSTERECTOMY AND ADMINISTRATION HIGH DOSE CALCIUM CARBONATE

    OpenAIRE

    Wiwik Misaco Yuniarti; Ira Sari Yudaniayanti; Nusdianto Triakoso

    2008-01-01

    The aim of this study was to determine the effect of high dose calcium carbonate in rat (Rattus norvegicus) following ovaryohysterectomy. A total of twenty female rats at 13 week-old were used in this study. Following ovaryohitectomy, the animals were randomized in four treatment groups. Group P0 were :fed with standard food only P1, P2 and P2 groups treated with standard food but supplemented calcium carbonate respectively at the dose of 75 mg per animal per day, 225 mg per animal per day , ...

  12. Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Sung Sil; Suh, Chang Ok; Kim, Gwi Eon [Yonsei Univ., Seoul (Korea, Republic of)

    2002-03-15

    High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of As Low As Reasonably Achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons . This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients are treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Polo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions 30cm x 30cm x 20cm. The anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is

  13. Hypertonic saline solution and high-dose furosemide infusion in cardiorenal syndrome: our experience

    Directory of Open Access Journals (Sweden)

    Francesco Ventrella

    2013-03-01

    Full Text Available Introduction Heart failure is frequently complicated by renal failure, and this association is a negative prognostic factor. These patients sometimes present oligo-/anuria and resistance to high-dose furosemide, a condition referred to as the cardiorenal syndrome (CRS. Acute or chronic reductions in left ventricular function result in decreased blood flow, with reduction of renal perfusion and activation of several neurohormonal systems, which cause resistance to diuretic therapy. This condition often requires ultrafiltration, which is an effective, but invasive and expensive procedure. Infusions of hypertonic saline solution (HSS and high-dose furosemide can be an effective alternative. Materials and methods From November 2009 through May 2010, our team treated 20 patients with CRS and resistance to iv boluses of high-dose furosemide. These patients were treated with small-volume (150-250 mL infusions of HSS (NaCl 1.57 – 4.5%, depending on serum Na values and high-dose furosemide twice a day. The aim of this treatment is to modify renal hemodynamics and the water-saline balance in the kidney by counteracting the extracellular fluid accumulation and eliminating symptoms of congestion. Results In 18 patients (90%, urine output was restored and renal function improved during the first hours of treatment. Clinical improvement was evident from the first day of therapy, and there were no adverse events. Two patients (10% did not respond to the treatment: one (who had been in critical condition since admission died; the other required regular sessions of ultrafiltration. Conclusions HSS combined with high-dose furosemide is a safe, effective, low-cost approach to the treatment of CRS that is resistant to diuretic therapy.

  14. Fundamental investigations of natural and laboratory generated SAR dose response curves for quartz OSL in the high dose range

    DEFF Research Database (Denmark)

    Timar-Gabor, Alida; Constantin, Daniela; Buylaert, Jan-Pieter

    2015-01-01

    SAR-OSL investigations on quartz from Romanian loess resulted in non concordant fine and coarse-grain ages for equivalent doses higher than ~100 Gy. The laboratory dose response for both grain sizes is well represented by a sum of two saturating exponential functions, fine and coarse grains chara...... equivalent dose of 2000e2500 Gy were found to be below the saturation level of the laboratory dose response curve for both grain sizes; this also applied to the luminescence signals measured after >5000 Gy given on top of natural doses. © 2015 Elsevier Ltd. All rights reserved....... characterised by D01 and D02 values of ~140 and ~1400 Gy and ~65 and ~650 Gy respectively. Pulsed OSL experiments confirmed that this behaviour is almost certainly inherent to quartz and not caused by contamination with another mineral. Natural doseeresponse curves do not follow the same pattern and enter...... saturation much earlier. Analysis of time resolved spectra indicated similar luminescence lifetimes for both fine and coarse quartz grains, and natural and laboratory generated OSL signals seem to use the same non-dosedependent recombination pathways. The natural signals of a sample with an expected...

  15. Long-term high-dose oral morphine in phantom limb pain with no addiction risk

    Directory of Open Access Journals (Sweden)

    Vinod Kumar

    2015-01-01

    Full Text Available Chronic phantom limb pain (PLP is a type of neuropathic pain, which is located in the missing/amputated limb. Phantom pain is difficult to treat as the exact basis of pain mechanism is still unknown. Various methods of treatment for PLP have been described, including pharmacological (NSAIDs, opioids, antiepileptic, antidepressants and non-pharmacological (TENS, sympathectomy, deep brain stimulation and motor cortex stimulation. Opioids are used for the treatment of neuropathic pain and dose of opioid is determined based on its effect and thus there is no defined ceiling dose for opioids. We report a case where a patient receiving high-dose oral morphine for chronic cancer pain did not demonstrate signs of addiction.

  16. Survey of pain specialists regarding conversion of high-dose intravenous to neuraxial opioids

    Directory of Open Access Journals (Sweden)

    Gorlin AW

    2016-09-01

    Full Text Available Andrew W Gorlin, David M Rosenfeld, Jillian Maloney, Christopher S Wie, Johnathan McGarvey, Terrence L Trentman Department of Anesthesiology, Mayo Clinic Arizona, Phoenix, AZ, USA Abstract: The conversion of high-dose intravenous (IV opioids to an equianalgesic epidural (EP or intrathecal (IT dose is a common clinical dilemma for which there is little evidence to guide practice. Expert opinion varies, though a 100 IV:10:EP:1 IT conversion ratio is commonly cited in the literature, especially for morphine. In this study, the authors surveyed 724 pain specialists to elucidate the ratios that respondents apply to convert high-dose IV morphine, hydromorphone, and fentanyl to both EP and IT routes. Eighty-three respondents completed the survey. Conversion ratios were calculated and entered into graphical scatter plots. The data suggest that there is wide variation in how pain specialists convert high-dose IV opioids to EP and IT routes. The 100 IV:10 EP:1 IT ratio was the most common answer of survey respondent, especially for morphine, though also for hydromorphone and fentanyl. Furthermore, more respondents applied a more aggressive conversion strategy for hydromorphone and fentanyl, likely reflecting less spinal selectivity of those opioids compared with morphine. The authors conclude that there is little consensus on this issue and suggest that in the absence of better data, a conservative approach to opioid conversion between IV and neuraxial routes is warranted. Keywords: intrathecal pump, epidural, cancer pain

  17. Survey of pain specialists regarding conversion of high-dose intravenous to neuraxial opioids.

    Science.gov (United States)

    Gorlin, Andrew W; Rosenfeld, David M; Maloney, Jillian; Wie, Christopher S; McGarvey, Johnathan; Trentman, Terrence L

    2016-01-01

    The conversion of high-dose intravenous (IV) opioids to an equianalgesic epidural (EP) or intrathecal (IT) dose is a common clinical dilemma for which there is little evidence to guide practice. Expert opinion varies, though a 100 IV:10:EP:1 IT conversion ratio is commonly cited in the literature, especially for morphine. In this study, the authors surveyed 724 pain specialists to elucidate the ratios that respondents apply to convert high-dose IV morphine, hydromorphone, and fentanyl to both EP and IT routes. Eighty-three respondents completed the survey. Conversion ratios were calculated and entered into graphical scatter plots. The data suggest that there is wide variation in how pain specialists convert high-dose IV opioids to EP and IT routes. The 100 IV:10 EP:1 IT ratio was the most common answer of survey respondent, especially for morphine, though also for hydromorphone and fentanyl. Furthermore, more respondents applied a more aggressive conversion strategy for hydromorphone and fentanyl, likely reflecting less spinal selectivity of those opioids compared with morphine. The authors conclude that there is little consensus on this issue and suggest that in the absence of better data, a conservative approach to opioid conversion between IV and neuraxial routes is warranted.

  18. Survey of pain specialists regarding conversion of high-dose intravenous to neuraxial opioids

    Science.gov (United States)

    Gorlin, Andrew W; Rosenfeld, David M; Maloney, Jillian; Wie, Christopher S; McGarvey, Johnathan; Trentman, Terrence L

    2016-01-01

    The conversion of high-dose intravenous (IV) opioids to an equianalgesic epidural (EP) or intrathecal (IT) dose is a common clinical dilemma for which there is little evidence to guide practice. Expert opinion varies, though a 100 IV:10:EP:1 IT conversion ratio is commonly cited in the literature, especially for morphine. In this study, the authors surveyed 724 pain specialists to elucidate the ratios that respondents apply to convert high-dose IV morphine, hydromorphone, and fentanyl to both EP and IT routes. Eighty-three respondents completed the survey. Conversion ratios were calculated and entered into graphical scatter plots. The data suggest that there is wide variation in how pain specialists convert high-dose IV opioids to EP and IT routes. The 100 IV:10 EP:1 IT ratio was the most common answer of survey respondent, especially for morphine, though also for hydromorphone and fentanyl. Furthermore, more respondents applied a more aggressive conversion strategy for hydromorphone and fentanyl, likely reflecting less spinal selectivity of those opioids compared with morphine. The authors conclude that there is little consensus on this issue and suggest that in the absence of better data, a conservative approach to opioid conversion between IV and neuraxial routes is warranted. PMID:27703394

  19. Usefulness evaluation of low-dose for emphysema: Compared with high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Jeong [Dept. of Radiological Technology, Daejeon Health Institute of Technology, Daejeon (Korea, Republic of)

    2016-09-15

    The purpose of this study was to evaluate the usefulness of low-dose CT (LDCT) for emphysema compared with high-resolution CT (HRCT). Measurements of radiation dose and noise were repeated 3 times in same exposure condition which was similar with obtaining HRCT and LDCT images. We analysed reading results of 146 subjects. Six images per participants selected for emphysema grading. Emphysema was graded for all 6 zones on the left and right sides of the lungs by the consensus reading of two chest radiologists using a 4-point scale. Between the HRCT and LDCT images, diagnostic differences and agreements for emphysema were analyzed by McNemar's and unweighted kappa tests, and radiation doses and noise by a Mann-Whitney U-test, using the SPSS 19.0 program. Radiation dose from HRCT was significantly higher than that of LDCT, but the noise was significantly lower in HRCT than in LDCT. Diagnostic agreement for emphysema between HRCT and LDCT images was excellent (k-value=0.88). Emphysema grading scores were not significantly different between HRCT and LDCT images for all six lung zones. Emphysema grading scores from LDCT images were significantly correlated with increased scores on HRCT images (r=0.599, p < 0.001). Considering the tradeoff between radiation dose and image noise, LDCT could be used as the gold standard method instead of HRCT for emphysema detection and grading.

  20. Sleep is more sensitive to high doses of caffeine in the middle years of life.

    Science.gov (United States)

    Robillard, Rébecca; Bouchard, Maude; Cartier, Annick; Nicolau, Laurence; Carrier, Julie

    2015-06-01

    During the middle years of life, sleep becomes more fragile and its sensitivity to psychostimulants may increase. This study evaluated the effects of 200 mg and 400 mg of caffeine on sleep in young and middle-aged adults. The sleep of 22 young (23.5 ± 1.9 years) and 24 middle-aged (51.7 ± 11.5 years) adults was recorded using polysomnography in two conditions (placebo and caffeine) in a double-blind cross-over design. Compared to placebo, caffeine increased sleep latency, shortened total sleep duration and reduced sleep efficiency. At the higher dose, these effects were more pronounced in middle-aged than in young adults. Furthermore, the higher dose of caffeine increased absolute stage 1 sleep in young adults, whereas it decreased absolute stage 2 sleep in middle-aged adults. Caffeine also induced dose-dependent increases in relative stage 1 sleep and reductions in absolute and relative slow wave sleep and absolute rapid eye movement sleep in both age groups. There was no dose- or age-related modulation of the effects of caffeine on quantified electroencephalographic measures. These results indicate that, compared to young adults, middle-aged adults are generally more sensitive to the effects of a high dose of caffeine on sleep quantity and quality.

  1. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Science.gov (United States)

    Salter, Bill J.; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-01

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min-1) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  2. Double Dose: High Family Conflict Enhances the Effect of Media Violence Exposure on Adolescents’ Aggression

    OpenAIRE

    Valkenburg, Patti M.; Vossen, Helen G.M.; Weeda, Wouter D.; Jessica Taylor Piotrowski; Karin M. Fikkers

    2013-01-01

    We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low conflict families. A total of 499 adolescents (aged 10 to 14, 48% girls) participated in a two-wave longitudinal survey (4-month interval). Survey questions assessed their exposure to violence on telev...

  3. Pharmacokinetics of high doses of cyanocobalamin administered by intravenous injection for 26 weeks in rats.

    Science.gov (United States)

    Nava-Ocampo, Alejandro A; Pastrak, Aleksandra; Cruz, Tony; Koren, Gideon

    2005-01-01

    1. High doses of vitamin B12 (cyanocobalamin) may be therapeutically effective to treat neurological alterations secondary to a wide range of disease states. The aim of the present study was to evaluate the effect of dose and repeated administration on the pharmacokinetics of cyanocobalamin in rats. 2. Forty-eight rats were randomly assigned to receive 1, 5, 25 or 100 mg/kg cyanocobalamin for 182 days (26 weeks). Cyanocobalamin plasma levels were quantified by HPLC on days 1, 85 and 182 of treatment and were analysed by means of non-compartment pharmacokinetic (PK) analysis. In addition, population PK analysis was used to fit cyanocobalamin plasma concentrations to time by means of a two-compartment model for intravascular administration. 3. The half-life of cyanocobalamin ranged from approximately 20 to 50 min, clearance ranged from 4.5 to 9 mL/min and the volume of distribution at steady state ranged from 140 to 470 mL. A statistically significant negative relationship existed between the dose of cyanocobalamin and the normalized area under the plasma concentration-time curve (AUC). This non-linearity was not exhibited in population PK analysis. No evidence of toxicity was observed. 4. At very high and prolonged doses (up to 100 mg/kg for 26 weeks), intravascular administration of cyanocobalamin in rats follows a two-compartment kinetic model and cyanocobalamin undergoes extensive extravascular distribution. The negative relationship between dose and normalized AUC is compatible with possible saturation of tubular reabsorption, thus increasing renal clearance at higher doses.

  4. Effects of high dose gamma irradiation on ITO thin film properties

    Energy Technology Data Exchange (ETDEWEB)

    Alyamani, A. [National Nanotechnology Center, King Abdul-Aziz City for Science and Technology (KACST), Riyadh (Saudi Arabia); Mustapha, N., E-mail: nazirmustapha@hotmail.com [Dept. of Physics, College of Sciences, Al Imam Mohammad Ibn Saud Islamic University, P.O. Box 90950, Riyadh 11623 (Saudi Arabia)

    2016-07-29

    Transparent thin-film Indium Tin Oxides (ITO) were prepared on 0.7 mm thick glass substrates using a pulsed laser deposition (PLD) process with average thickness of 150 nm. The samples were then exposed to high gamma γ radiation doses by {sup 60}Co radioisotope. The films have been irradiated by performing exposure cycles up to 250 kGy total doses at room temperature. The surface structures before and after irradiation were analysed by x-ray diffraction. Atomic Force Microscopy (AFM) was performed on all samples before and after irradiation to investigate any change in the grain sizes, and also in the roughness of the ITO surface. We investigated the influence of γ irradiation on the spectra of transmittance T, in the ultraviolet-visible-near infrared spectrum using spectrophotometer measurements. Energy band gap E{sub g} was then calculated from the optical spectra for all ITO films. It was found that the optical band gap values decreased as the radiation dose was increased. To compare the effect of the irradiation on refractive index n and extinction coefficient k properties, additional measurements were done on the ITO samples before and after gamma irradiation using an ellipsometer. The optical constants n and k increased by increasing the irradiation doses. Electrical properties such as resistivity and sheet resistance were measured using the four-point probe method. The good optical, electrical and morphological properties maintained by the ITO films even after being exposed to high gamma irradiation doses, made them very favourable to be used as anodes for solar cells and as protective coatings in space windows. - Highlights: • Indium Tin Oxide (ITO) thin films were deposited by pulsed laser deposition. • Effects of Gamma irradiation were investigated. • Changes of optical transmission and electrical properties of ITO films were studied. • Intensity of the diffraction peaks and the film's structure changed with increasing irradiation doses.

  5. Low-dose, high-resolution and high-efficiency ptychography at STXM beamline of SSRF

    Science.gov (United States)

    Xu, Zijian; Wang, Chunpeng; Liu, Haigang; Tao, Xulei; Tai, Renzhong

    2017-06-01

    Ptychography is a diffraction-based X-ray microscopy method that can image extended samples quantitatively while remove the resolution limit imposed by image-forming optical elements. As a natural extension of scanning transmission X-ray microscopy (STXM) imaging method, we developed soft X-ray ptychographic coherent diffraction imaging (PCDI) method at the STXM endstation of BL08U beamline of Shanghai Synchrotron Radiation Facility. Compared to the traditional STXM imaging, the new PCDI method has resulted in significantly lower dose, higher resolution and higher efficiency imaging in our platform. In the demonstration experiments shown here, a spatial resolution of sub-10 nm was obtained for a gold nanowires sample, which is much better than the limit resolution 30 nm of the STXM method, while the radiation dose is only 1/12 of STXM.

  6. Changes in choroidal thickness after systemic administration of high-dose corticosteroids: a pilot study.

    Science.gov (United States)

    Han, Jeong Mo; Hwang, Jeong-Min; Kim, Ji Soo; Park, Kyu Hyung; Woo, Se Joon

    2014-01-21

    To characterize the effects of corticosteroids on choroidal thickness, we measured the choroid thickness in patients treated systemically with a high-dose corticosteroid. A prospective, pilot study was conducted on 20 patients who required high-dose corticosteroid pulse therapy (>500 mg/d). Choroidal thickness was measured at baseline, 1 day, 1 week, and 1 month after corticosteroid administration. Blood pressure was measured four times a day for the first 5 days of steroid treatment. This study ultimately included 35 eyes from 18 patients. Each patient was treated with high-dose corticosteroid therapy at a concentration of 19.5 ± 4.1 mg per kg body weight for 5.2 ± 1.1 days. Mean subfoveal choroidal thickness at baseline was 259.8 μm (range, 86.4-394.7 μm). Choroidal thickness showed no significant change at 1 day, 1 week, or 1 month after corticosteroid administration (P = 0.197). Mean systolic blood pressure increased by 13 mmHg (P = 0.008), but diastolic pressure did not change (P = 0.117). One patient (5.6%) who had presented with pigment epithelial detatchment (PED) and thick choroid (381.1 μm) developed bilateral focal subretinal fluid during the study and showed central serous chorioretinopathy (CSC) with a 13.1% increase in subfoveal choroidal thickness. No consistent changes in choroidal thickness were observed after systemic high-dose corticosteroid treatment, but one patient with PED and thick choroid showed an increase in choroidal thickening as well as features of CSC. Thus, steroid-induced CSC may be an idiosyncratic response in selected vulnerable individuals rather than a dose-dependent effect.

  7. 7-OH-DPAT effects on latent inhibition: low dose facilitation but high dose blockade: implications for dopamine receptor involvement in attentional processes.

    Science.gov (United States)

    Chagas-Martinich, Ligia; Carey, Robert J; Carrera, Marinete Pinheiro

    2007-03-01

    7-OH-DPAT is a dopamine D2/D3 agonist, which at low doses acts preferentially on D3 receptors but at high doses it acts on D2 and D3 receptors. The present study investigated the contribution of D3 and D2 receptors on latent inhibition (LI) by using two dose levels of 7-OH-DPAT: a low dose, 0.1 mg/kg (D3 receptor activation) and a high dose, 1.0 mg/kg, (D2/D3 receptor activation) in a conditioned emotional response (CER) paradigm. The LI Protocols included CS pre-exposure (10 or 40 CS alone trials), CER induction and a non-drug CER test phase. Additionally, the drug effects upon CER acquisition without LI were assessed using the same treatments and test environment pre-exposure protocols but without the tone CS. The effects of 7-OH-DPAT on crossing, rearing and grooming were also measured in an open field 1 day after the CER test phase. The results showed that the low dose 7-OH-DPAT treatment potentiated LI at 10 but not at 40 CS pre-exposures. The high dose 7-OH-DPAT treatment blocked LI at both the 10 and 40 stimulus pre-exposures; and it also induced hyperactivity. Thus, D3 stimulation induced by a low dose of 7-OH-DPAT can facilitate LI but these effects are contingent upon and are specific to the number of stimulus presentations. Altogether, these findings indicate that D3 stimulation can enhance attentional processes, but D2 stimulation can impair attentional processes.

  8. [High-dose magnesium sulfate in the treatment of aconite poisoning].

    Science.gov (United States)

    Clara, A; Rauch, S; Überbacher, C A; Felgenhauer, N; Drüge, G

    2015-05-01

    This article reports the case of a 62-year-old male patient who ingested the roots of Monkshood (Aconitum napellus) and white hellebore (Veratrum album) dissolved in alcohol with a suicidal intention and suffered cardiotoxic and neurotoxic symptoms. After contacting the Poison Information Centre ventricular arrhythmia was treated with high-dose magnesium sulphate as the only antiarrhythmic agent and subsequently a stable sinus rhythm could be established after approximately 3 h. Aconitum napellus is considered the most poisonous plant in Europe and it is found in gardens, the Alps and the Highlands. Poisoning is mainly caused by the alkaloid aconite that leads to persistent opening and activation of voltage-dependent sodium channels resulting in severe cardiac and neurological toxicity. As no specific antidote is known so far, poisoning is associated with a high mortality. The therapy with high-dose magnesium sulphate is based on in vitro and animal experiments as well as limited clinical case reports.

  9. No seasonal accumulation of resistant P. falciparum when high-dose chloroquine is used

    DEFF Research Database (Denmark)

    Ursing, Johan; Kofoed, Poul-Erik; Rodrigues, Amabelia

    2009-01-01

    BACKGROUND: Potentially chloroquine resistant P. falciparum, identified by the 76T haplotype in the chloroquine resistance transporter (pfcrt 76T), are highly prevalent throughout Africa. In Guinea-Bissau, normal and double dose chloroquine have respective efficacies of 34% and 78% against P...... increase of pfcrt 76T if the high doses of CQ commonly used are effective. METHODS AND FINDINGS: P. falciparum parasite density, age, sex, the proportion of chloroquine resistance associated haplotypes pfcrt 76T and P. falciparum multidrug resistance gene 1 86Y were assessed in 988 samples collected from...... children between 2002 and 2007. There was no seasonal accumulation of any allele. During the high and low transmission periods the pfcrt 76T proportions were 24% (95% CI, 21-27%) and 26% (95% CI, 20-33%). There was no significant change of pfcrt 76T (OR 1.05, 95% CI; 0.94-1.16 p = 0.39) or pfmdr1 86Y (OR 0...

  10. Synergies Between ' and Cavity Formation in HT-9 Following High Dose Neutron Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Parish, Chad M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Saleh, Tarik A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Eftink, Benjamin P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Candidate cladding materials for advanced nuclear power reactors including fast reactor designs require materials capable of withstanding high dose neutron irradiation at elevated temperatures. One candidate material, HT-9, through various research programs have demonstrated the ability to withstand significant swelling and other radiation-induced degradation mechanisms in the high dose regime (>50 displacements per atom, dpa) at elevated temperatures (>300 C). Here, high efficiency multi-dimensional scanning transmission electron microscopy (STEM) acquisition with the aid of a three-dimensional (3D) reconstruction and modeling technique is used to probe the microstructural features that contribute to the exceptional swelling resistance of HT-9. In particular, the synergies between ' and fine-scale and moderate-scale cavity formation is investigated.

  11. Late relapses in primary CNS lymphoma after complete remissions with high-dose methotrexate monotherapy

    Science.gov (United States)

    Ambady, Prakash; Holdhoff, Matthias; Bonekamp, David; Wong, Fay; Grossman, Stuart A

    2015-01-01

    Treatment of patients with newly diagnosed primary CNS lymphomas using high dose methotrexate regimens is reported to yield about 30% long term survivors with minimal neurotoxicity. As in other systemic large cell lymphomas, it is generally assumed that most relapses occur within 5 years of diagnosis. A retrospective review of the Johns Hopkins experience in 52 patients treated between 1995 and 2008 yielded 19 patients (37%) who achieved a complete response and were followed for over 5 years. Four of these patients remained progression-free for over 10 years. However, two of these long-term survivors have now relapsed over 10 years after their initial diagnosis. An analysis of progression and overall survival does not reveal a plateau suggesting that even patients who have not recurred for over 10 years remain at high risk for relapse after treatment with single agent high dose methotrexate. PMID:26507609

  12. Feasibility and safety of high-dose adenosine perfusion cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Holloway Cameron J

    2010-11-01

    Full Text Available Abstract Introduction Adenosine is the most widely used vasodilator stress agent for Cardiovascular Magnetic Resonance (CMR perfusion studies. With the standard dose of 140 mcg/kg/min some patients fail to demonstrate characteristic haemodynamic changes: a significant increase in heart rate (HR and mild decrease in systolic blood pressure (SBP. Whether an increase in the rate of adenosine infusion would improve peripheral and, likely, coronary vasodilatation in those patients is unknown. The aim of the present study was to assess the tolerance and safety of a high-dose adenosine protocol in patients with inadequate haemodynamic response to the standard adenosine protocol when undergoing CMR perfusion imaging. Methods 98 consecutive patients with known or suspected coronary artery disease (CAD underwent CMR perfusion imaging at 1.5 Tesla. Subjects were screened for contraindications to adenosine, and an electrocardiogram was performed prior to the scan. All patients initially received the standard adenosine protocol (140 mcg/kg/min for at least 3 minutes. If the haemodynamic response was inadequate (HR increase Results All patients successfully completed the CMR scan. Of a total of 98 patients, 18 (18% did not demonstrate evidence of a significant increase in HR or decrease in SBP under the standard adenosine infusion rate. Following the increase in the rate of infusion, 16 out of those 18 patients showed an adequate haemodynamic response. One patient of the standard infusion group and two patients of the high-dose group developed transient advanced AV block. Significantly more patients complained of chest pain in the high-dose group (61% vs. 29%, p = 0.009. On multivariate analysis, age > 65 years and ejection fraction Conclusions A substantial number of patients do not show adequate peripheral haemodynamic response to standard-dose adenosine stress during perfusion CMR imaging. Age and reduced ejection fraction are predictors of inadequate

  13. High dose 1,25(OH)2D3 inhibits osteoblast mineralization in vitro.

    Science.gov (United States)

    Yamaguchi, Masayoshi; Weitzmann, M Neale

    2012-05-01

    Vitamin D is essential for optimal calcium absorption needed for maintaining normal bone mineral density (BMD). Consequently, vitamin D-deficiency leads to poorly mineralized bone with diminished strength and load bearing capacity. Surprisingly, several animal and clinical studies have identified suppressive effects of high dose vitamin D supplementation on bone formation. These data suggest that while vitamin D is necessary for basal bone homeostasis, excessive concentrations may be detrimental to the skeleton. To further examine the direct effects of high dose vitamin D on the function of osteoblasts we differentiated primary osteoblast precursors and MC3T3 preosteoblastic cells, in the presence of supraphysiological doses of the active metabolite, 1,25-dihydroxyvitamin D3 [1,25(OH)2D3]. In vitro osteoblast mineralization was potently suppressed by high dose 1,25(OH)2D3. To investigate the mechanism we used a bioassay to examine nuclear factor-κB (NF-κB) activation in MC3T3 cells. Although NF-κB agonists are generally potent inhibitors of osteoblast differentiation, surprisingly, 1,25(OH)2D3 dose-dependently suppressed, rather than stimulated, NF-κB activation. Interestingly, 1,25(OH)2D3 also suppressed Smad activation induced by the osteoblast commitment and differentiation factors transforming growth factor-β (TGF-β) and bone morphogenetic protein 2 (BMP2), which may account for the inhibitory activities of 1,25(OH)2D3 on mineralization. Our data suggest that vitamin D has complex pleiotropic effects on osteoblast signal transduction. As the net balance of high dose 1,25(OH)2D3 appears to be an inhibitory action on osteoblasts, our data suggest that the therapeutic value of vitamin D to maximize bone mass through indirect actions on calcium absorption may need to be carefully balanced with potential inhibitory direct effects on mineralizing cells. Our data suggest that indiscriminate over-dosing may be detrimental to bone formation and optimal

  14. Range shift and dose perturbation with high-density materials in proton beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Nichiporov, D., E-mail: nichipor@indiana.edu [Indiana University Integrated Science and Technology Hall, 2401 Milo B. Sampson La, Bloomington, IN 47408-1398 (United States); Moskvin, V. [Indiana University School of Medicine, 535 Barnhill Dr., RT 041, Indianapolis, IN 46202 (United States); Indiana University Health Proton Therapy Center, 2425 Milo B. Sampson La, Bloomington, IN 47408 (United States); Fanelli, L. [Indiana University Health Proton Therapy Center, 2425 Milo B. Sampson La, Bloomington, IN 47408 (United States); Das, I.J. [Indiana University School of Medicine, 535 Barnhill Dr., RT 041, Indianapolis, IN 46202 (United States); Indiana University Health Proton Therapy Center, 2425 Milo B. Sampson La, Bloomington, IN 47408 (United States)

    2011-11-15

    Radiotherapy with proton beams requires accurate knowledge of the proton range. When materials with high atomic numbers (Z) and densities (e.g. prostheses or implants) are present in the patient, they give rise to pronounced uncertainties in computed tomography data and to large errors in proton range and dose calculations. A modified analytical expression is proposed for the observed range shift in water in the presence of a high-density material of known thickness and density. The expression was verified experimentally in a clinical beam with various thicknesses and materials in a water phantom, at several beam ranges and at different depths. Measurements were also made behind the medium-to-water interface to evaluate dose perturbation using a thin window parallel plate ion chamber. Primary particle fluence variations due to the range shift were studied in a separate experiment. The measured range shift was in good agreement ({+-}0.3 mm) with the analytical expression for most of the materials studied. A small, but consistent dependence of range shift on the energy of impinging protons was found. Dose perturbation factor in water downstream of the material is less than +5% for thicknesses up to 8 g/cm{sup 2}. The proposed analytical expression can be used in clinical situations to determine the range shift in patient caused by an implanted material. Dose perturbation in the presence of an implant is due to the changes in primary particle fluence resulting from several physical processes.

  15. Primary treatment of acromegaly with high-dose lanreotide: a case series

    Directory of Open Access Journals (Sweden)

    Cordes Uwe

    2010-03-01

    Full Text Available Abstract Introduction The first-line treatment for acromegaly is transsphenoidal surgery. In approximately 50% of patients, however, a cure is not possible with surgery and alternatives are needed. Somatostatin analog therapy is the recommended first-line treatment in patients with such cases. Here we provide the first report of a high-dose lanreotide primary therapy in patients with acromegaly. Case presentation Six patients who were not suitable for surgery were given 60 mg of lanreotide (Autogel® every four weeks. All patients were German nationals and Caucasian. When the response of our patients was unsatisfactory, the dose was increased sequentially to 90 mg every four weeks, 120 mg every four weeks, 120 mg every three weeks and 180 mg every three weeks. Treatment duration was 12 to 24 months. In all cases, the lanreotide dose was 120 mg every 4 weeks or higher. In five of our patients, growth hormone (GH levels were successfully reduced (in three patients GH Tumor shrinkage or degeneration was observed in the five responding patients. No drug-related adverse events were noted. Conclusions These results suggest that lanreotide at high doses of 120 mg every four weeks or more is an effective first-line therapy for patients with acromegaly that surgery alone cannot treat.

  16. Effect of graded doses and a high dose of microbial phytase on the digestibility of various minerals in weaner pigs

    NARCIS (Netherlands)

    Kies, A.K.; Kemme, P.A.; Sebek, L.B.J.; Diepen, van J.T.M.; Jongbloed, A.W.

    2006-01-01

    An experiment with 224 weaner pigs (initial BW of 7.8 kg) was conducted to determine the effect of dose of dietary phytase supplementation on apparent fecal digestibility of minerals (P, Ca, Mg, Na, K, and Cu) and on performance. Four blocks, each with 8 pens of 7 pigs, were formed. Eight dietary tr

  17. The Effect of High Dose Radioiodine Therapy on Formation of Radiation Retinopathy During Thyroid Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Tülay Kaçar Güvel

    2014-10-01

    Full Text Available Objective: Non-thyroidal complication of high-dose radioiodine therapy for thyroid carcinoma might cause salivary and lacrimal gland dysfunction, which may be transient or permanent in a dose-dependent manner. However, radiation retinopathy complicating 131I therapy, has not been previously well characterized. The aim of this study was to evaluate the extent of retinal damage among patients who had received high doses of radioiodine treatment. Methods: Forty eyes of 20 patients (3 male, 17 female who received 250-1000 mCi during 131I therapy and on ophthalmological follow up for a year after the last treatment were included in the study. Mean age of the study group was 50 years (range 25-70 years. In ophthalmologic examination, visual acuity was measured in order to determine visual loss. Intraocular pressure was measured in all the patients. Then lens examination was carried out with slit lamp biomicroscopy in order to investigate cataract or partial lens opacities. Fundus observation was carried out through the dilated pupil with slit lamp biomicroscopy using 90 D noncontact lens. Result: The best corrected visual aquity with Snellen chart was found as 1.0 in 36 eyes (90% and between 0.6 and 0.9 (10% in 4 eyes (10%. At the biomicroscopic fundus examination, retinal hemorrhage consistent with radiation retinopathy, microaneurysm, microinfarction, edema or exudation, vitreus hemorrhage, partial or total optical disc pallor indicating papillopathy in the optic disc were not observed in any of the eyes. Conclusion: This result indicates that there is not any significant correlation between repeated high-dose radioiodine therapy and radiation retinopathy in differentiated thyroid carcinomas. Even though there is not a significant restriction in use of higher doses of radioiodine therapy in differentiated thyroid carcinoma, more extensive studies are needed in order to obtain more accurate data on possible occurrence of retinopathy.

  18. High dose rate brachytherapy in early stage squamous-cell carcinoma of the lip.

    Science.gov (United States)

    Mut, Alejandro; Guinot, José Luis; Arribas, Leoncio; Díez-Presa, Lorena; Tortajada, María Isabel; Santos, Miguel Ángel; Samper, Josefa; Santamaría, Paula; Vendrell, Juan Bosco

    2016-01-01

    To analyze the results obtained after treatment of early stage (T1-T2) squamous cell carcinoma of the lip with high dose rate brachytherapy and evaluate the efficacy of this treatment in both local and regional control. Retrospective analysis of the treatments performed at our department from March 1999 to March 2013 with high dose rate brachytherapy with rigid needles. We included 68 patients, 63 men and 5 women; 37 patients (54.4%) presented a T1 tumour, less than or equal to 2cm, while the other 31 (45.6%) were classified as T2. Median total dose was 45Gy, with a median dose per fraction of 5Gy x 9 fractions twice a day for 5 days. With a mean follow-up of 56.4 months, local control was 96.9%. Stratifying by tumour size, local control of T1 cases was 100%, while T2 achieved 93.2% (2 local recurrences). Regional control at 5 years was 93.8% for T1, and 80.8% for T2. In 11 cases with elective cervical treatment, no regional failure happened. As for toxicity, no patient presented soft tissue, or bone, necrosis. All patients achieved good or excellent cosmetic and functional results. High dose rate brachytherapy allows effective, safe treatments for squamous cell carcinoma of the lip, with good aesthetic and functional results. It can be considered a valid alternative for surgery in early stage tumours. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  19. Clinical transition to model-based dose calculation algorithm: A retrospective analysis of high-dose-rate tandem and ring brachytherapy of the cervix.

    Science.gov (United States)

    Jacob, Dayee; Lamberto, Melissa; DeSouza Lawrence, Lana; Mourtada, Firas

    To retrospectively compare clinical dosimetry of CT-based tandem-ring treatment plans using a model-based dose calculation algorithm (MBDCA) with the standard TG-43-based dose formalism. A cohort of 10 cervical cancer cohorts treated using the tandem and ring high-dose-rate applicators were evaluated. The original treatment plans were created using the department CT-based volume optimization clinical standards. All plans originally calculated with TG-43 dose calculation formalism were recalculated using the MBDCA algorithm. The gross target volume and organs at risk (OARs) were contoured on each data set along with significant heterogeneities like air in cavity and high-density plastic tandem and ring components. The patient tissue was modeled as homogenous liquid water. D90, D95, and D100 for gross target volume, D0.1cm(3), D1.0cm(3), and D2.0cm(3) for bladder, rectum, and sigmoid were extracted from dose-volume histograms for TG-43 and MBDCA calculated plans. Mean absolute difference ± 2σ in the above metrics was calculated for each plan. Using the manual applicator contouring method, MBDCA plans (n = 10) showed 2.1 ± 1.1% reduction in dose to Point A average, 2.6 ± 0.9% reduction in Target D90 dose, and 2.1 ± 0.3% dose reduction to OARs. Results from plans using vendor supplied solid applicator models (n = 5) showed 2.2 ± 1.10% reduction in dose to Point A average, 2.7 ± 0.2% reduction in Target D90 dose, and 2.7 ± 1.0% dose reduction on average to OARs. For unshielded plastic gynecologic applicators, minimal dosimetric changes (<5%) were found using MBDCA relative to standard TG-43. Use of solid applicator model is more efficient than manual applicator contouring and also yielded similar MBDCA dosimetric results. Currently, TG-186 dose calculations should be reported along TG-43 until we obtain studies with larger cohorts to fully realize the potential of MBDCA dosimetry. Copyright © 2017 American Brachytherapy Society. Published by

  20. Clinical implementation of a novel applicator in high-dose-rate brachytherapy treatment of esophageal cancer

    Directory of Open Access Journals (Sweden)

    Ivan M. Buzurovic

    2016-08-01

    Full Text Available Purpose : In this study, we present the clinical implementation of a novel transoral balloon centering esophageal applicator (BCEA and the initial clinical experience in high-dose-rate (HDR brachytherapy treatment of esophageal cancer, using this applicator. Material and methods: Acceptance testing and commissioning of the BCEA were performed prior to clinical use. Full performance testing was conducted including measurements of the dimensions and the catheter diameter, evaluation of the inflatable balloon consistency, visibility of the radio-opaque markers, congruence of the markers, absolute and relative accuracy of the HDR source in the applicator using the radiochromic film and source position simulator, visibility and digitization of the applicator on the computed tomography (CT images under the clinical conditions, and reproducibility of the offset. Clinical placement of the applicator, treatment planning, treatment delivery, and patient’s response to the treatment were elaborated as well. Results : The experiments showed sub-millimeter accuracy in the source positioning with distal position at 1270 mm. The digitization (catheter reconstruction was uncomplicated due to the good visibility of markers. The treatment planning resulted in a favorable dose distribution. This finding was pronounced for the treatment of the curvy anatomy of the lesion due to the improved repeatability and consistency of the delivered fractional dose to the patient, since the radioactive source was placed centrally within the lumen with respect to the clinical target due to the five inflatable balloons. Conclusions : The consistency of the BCEA positioning resulted in the possibility to deliver optimized non-uniform dose along the catheter, which resulted in an increase of the dose to the cancerous tissue and lower doses to healthy tissue. A larger number of patients and long-term follow-up will be required to investigate if the delivered optimized treatment can

  1. The efficiency of high dose botulinum toxin type-A in the treatment of cerebral palsy

    Directory of Open Access Journals (Sweden)

    Alper İbrahim Dai

    2014-03-01

    Full Text Available Objective: Cerebral palsy is the most common cause of severe physical disability in childhood. Botulinum toxin type A (BTX-A, has rapidly gained acceptance as a different treatment for spasticity. However, no consensus exists among clinicians about optimal dose of BTX-A in pediatric patients. Doses of 2-6 U/ kg bodyweight with a maximum total dose of 29U/kg have been reported. This study was conducted due to uncertain dosage rage in pediatric use. Method: In this study, 12 patients with cerebral palsy and spastic eqinus foot deformity who referred to our center, were treated with BTX-A in the dosage of 25 U/kg. After treatment of BTX-A, patients were followed up total of 6 months. Three months after treatment, Gross motor functional measurement (GMFM and Modified Ashwort scale (MAS were done. At the same time, questionnaires (PCQ were filled for possible side effects. Results: Average age of 6 girls and 6 boys were 4.5 ± 2.8 years. GMFM and MAS were done before and 3 months after treatment and were found statistically significant (p<0.05. Muscle soreness was the most common symptom at PCQ forms. Conclusion: Using these two objective scales and PCQ form, high dose of BTX-A treatment was found statistically successful. Larger dose of BTX-A was used which was considered safe, effective and better tolerated by children. Titration of the dose of BTX-A, should be individualized for each patient due to different level of spasticity affecting patients in different ways. J Clin Exp Invest 2014; 5 (1: 93-97

  2. Proconvulsant effects of high doses of venlafaxine in pentylenetetrazole-convulsive rats

    Directory of Open Access Journals (Sweden)

    J.G. Santos Junior

    2002-04-01

    Full Text Available Venlafaxine, an atypical antidepressant drug, has been used to treat several neurological disorders, presenting excellent efficacy and tolerability. Clinical seizures after venlafaxine treatment have occasionally been reported when the drug was used at very high doses or in combination with other medications. The aim of the present study was to investigate the convulsant effects of venlafaxine in rats under controlled laboratory conditions. Adult male Wistar rats (8 per group receiving venlafaxine or saline at the doses of 25-150 mg/kg were subjected 30 min later to injections of pentylenetetrazole at the dose of 60 mg/kg. The animals receiving 75, 100 and 150 mg/kg venlafaxine presented increased severity of convulsion when compared to controls (P = 0.02, P = 0.04, and P = 0.0004, respectively. Indeed, an increased percentage of death was observed in these groups (50, 38, and 88%, respectively when compared to the percentage of death in the controls (0%. The group receiving 150 mg/kg showed an reduction in death latency (999 ± 146 s compared to controls (1800 ± 0 s; cut-off time. Indeed, in this group, all animals developed seizures prior to pentylenetetrazole administration. Surprisingly, the groups receiving venlafaxine at the doses of 25 and 50 mg/kg showed a tendency towards an increase in the latency to the first convulsion. These findings suggest that venlafaxine at doses of 25 and 50 mg/kg has some tendency to an anticonvulsant effect in the rat, whereas doses of 75, 100 and 150 mg/kg presented clear proconvulsant effects in rats submitted to the pentylenetetrazole injection. These findings are the first report in the literature concerning the role of venlafaxine in seizure genesis in the rat under controlled conditions.

  3. High-dose-rate-intracavitary brachytherapy applications and the difference in the bladder and rectum doses: A study from rural centre of Maharashatra, India

    Directory of Open Access Journals (Sweden)

    Jain Vandana

    2007-01-01

    Full Text Available Aim : To report the difference in the bladder and rectum doses with different applications by the radiotherapists in the same patient of the carcinoma of the uterine cervix treated by multiple fractions of high-dose-rate (HDR intracavitary brachytherapy (ICBT. Materials and Methods : Between January 2003 to December 2004, a total of 60 cases of the carcinoma uterine cervix were selected randomly for the retrospective analyses. All 60 cases were grouped in six groups according to the treating radiotherapist who did the HDR-ICBT application. Three radiotherapists were considered for this study, named A, B and C. Ten cases for each radiotherapist in whom all three applications were done by the same radiotherapist. And 10 cases for each radiotherapist with shared applications in the same patient (A+B, A+C and B+C. The bladder and rectal doses were calculated in reference to point "A" dose and were limited to 80% of prescribed point "A" dose, as per ICRU-38 recommendations. Received dose grouped in three groups- less then 80% (< 80%, 80-100% and above 100% (>100%. A total of 180 applications for 60 patients were calculated for the above analyses. Results : There is a lot of difference in the bladder and rectal doses with the application by the different radiotherapists, even in the same patient with multiple fractions of HDR-ICBT. Applications by ′A′ radiotherapist were within the limits in the self as well as in the shared groups more number of times, by ′B′ radiotherapist was more times exceeding the limit and by ′C′ radiotherapist doses were in between the A and B. Discussion and Conclusion : For the rectal and bladder doses most important factors are patient′s age, disease stage, duration between EBRT and HDR-ICRT and patient anatomy, but these differences can be minimized to some extent by careful application, proper packing and proper fixation.

  4. High doses of carbamazepine for refractory partial epilepsy Altas doses de carbamazepina para epilepsia parcial refratária

    Directory of Open Access Journals (Sweden)

    Cristiana Borges Pereira

    1996-03-01

    Full Text Available Forty-eight patients with partial seizures were analysed during treatment with 1200 mg/d or more of carbamazepine (CBZ. Thirty-three were on monotherapy and fifteen on polytherapy. The other drugs were kept unchanged in the patients on polytherapy. The dose of CBZ was increased if no control was observed and the patient had no side effects. The doses used ranged between 1200 and 1900 mg/day (1200 mg/day, n=18; 1300mg/day, n=1; 1400 mg/day, n=7; 1600 mg/day, n=9; 1700 mg/day, n=4; 1800 mg/day, n=8; 1900 mg/day, n=1. Anticonvulsant plasma levels were taken to confirm patient compliance. The average plasma level was 9.6 ug/mL. The period of follow up varied from 3 to 96 months (M=25.6. Seizure's control was observed in 7 (14.48% patients taking 1200 mg/day and in 2 (4.16% patients taking 1400 mg/day of CBZ. Thirty-nine patients did not show any control (81.21%. Ten patients (20.81% had signs of intoxication. When patients have no improvement with 1400 mg/day, it is difficult to obtain any control despite the use of higher doses of CBZ, which frequently expose the patient to significant side effects.Foram analisados 48 pacientes epilépticos com crises parciais que faziam uso de carbamazepina (CBZ em doses iguais ou superiores a 1200 mg por dia. Trinta e três estavam em monoterapia e 15 em politerapia. As outras medicações foram mantidas constantes durante a manipulação da dose de CBZ nos pacientes em politerapia. O critério utilizado para o aumento da dose de CBZ foi a falta de controle clínico e a ausência de efeitos colaterais (independente da dosagem sérica. A dose máxima variou de 1200 a 1900 mg/dia (1200 mg, n=18; 1300 mg/dia, n=1; 1400 mg/dia, n=7; 1600 mg/dia, n=9; 1700 mg/dia, n=4; 1800 mg/dia, n=8 ; 1900 mg/dia, n=1. Dosagens séricas de anticonvulsivantes eram utilizadas no sentido de confirmar a aderência ao tratamento. A média das dosagens disponíveis foi de 9,6 ug/mL. O tempo de seguimento variou de 3 a 96 meses (M=25

  5. High-dose aspirin in addition to daily low-dose aspirin decreases platelet activation in patients before and after percutaneous coronary intervention.

    Science.gov (United States)

    ten Berg, Jurriën M; Gerritsen, Wim B M; Haas, Fred J L M; Kelder, Hans C; Verheugt, Freek W A; Plokker, H W Thijs

    2002-03-01

    Activated platelets play a major role in acute vessel closure after coronary angioplasty. Although aspirin is the routine therapy during angioplasty, it only incompletely prevents acute closure. This might be due to suboptimal dosing. First, to study the effect of additional high-dose aspirin on platelet activation during coronary angioplasty. Second, to assess the potential of the new PFA-100 analyzer to evaluate the effect of different doses of aspirin in patients undergoing angioplasty. Fifty-one patients on 100 mg aspirin/day for at least 1 month were randomized to continuation of 100 mg aspirin/day only (Group A=24 patients), or to this regime plus a bolus of 1000 mg of aspirin given 1 day before angioplasty (Group B=27 patients). Results were compared with 15 controls. Platelet function was measured before angioplasty by the PFA-100 analyzer; platelet activation was measured by flow cytometry just before and 1 h after angioplasty. At baseline, Group A had significantly more activated platelets than the control group (P<.001). High-dose aspirin in Group B resulted in significantly lower platelet activation as compared with both controls (P<.001) and Group A (P<.001). During angioplasty, the number of activated platelets decreased significantly in Group A (P<.001), while there was no change in Group B (P=.6). The PFA-100 analyzer was unable to detect differences between the two treatment groups. The addition of high-dose aspirin to daily low-dose aspirin, 1 day before coronary angioplasty, significantly reduced the platelet activation state before and after intervention. The PFA-100 analyzer did not detect differences in the effect of low- versus high-dose aspirin on platelet function.

  6. High-dose insulin: a consecutive case series in toxin-induced cardiogenic shock.

    Science.gov (United States)

    Holger, Joel S; Stellpflug, Samuel J; Cole, Jon B; Harris, Carson R; Engebretsen, Kristin M

    2011-08-01

    Cardiovascular medication overdoses can be difficult to treat. Various treatment modalities are currently recommended. To describe patient outcomes and adverse events of high-dose insulin therapy in consecutive overdose patients in cardiogenic shock after implementation of a high-dose insulin protocol (1-10 U/kg/h, while avoiding or tapering off vasopressors). This is an observational consecutive case series of patients identified from a registry. Data were collected by retrospective chart review of patients treated by our toxicology service with this protocol from February 2007 until March 2010. Twelve patients were treated with high-dose insulin. The mean age was 36.5 years (SD 11.7). Seven patients had pre-existing vasopressor therapy, and all were tapered off vasopressors while on insulin. Two patients experienced pulseless electrical activity cardiac arrest prior to high-dose insulin therapy. Intravenous fat emulsion was given to two patients. The mean maximum insulin infusion rate was 8.35 U/kg/h (mean = 8.35, SD 6.34). The mean duration of insulin infusion was 23.5 h (SD 19.7). The mean duration of glucose infusion post-insulin was 25.2 h (SD 17.7). The primary toxins were β-blocker in five, calcium channel blocker in two, combined β-blocker/calcium channel blocker in two, tricyclic antidepressant in one, and polydrug in 2. CLINICAL OUTCOMES: Eleven of 12 patients survived. One patient expired 9 h into insulin therapy from cardiac arrest shortly after the insulin was stopped and a vasopressor re-initiated (protocol deviation). Six patients experienced a total of 19 hypoglycemic events. Hypokalemia (defined as insulin therapy. One patient was discharged with mild anoxic injury thought due to pulseless electrical activity arrest prior to insulin therapy. Three of these 12 patients have been previously described in published case reports. High-dose insulin therapy based on a 1-10 U/kg/h dosing guideline and recommending avoidance of vasopressors appears to be

  7. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.

    Science.gov (United States)

    Chibani, Omar; Ma, Chang-Ming Charlie

    2003-08-01

    The dose from photon-induced nuclear particles (neutrons, protons, and alpha particles) generated by high-energy photon beams from medical linacs is investigated. Monte Carlo calculations using the MCNPX code are performed for three different photon beams from two different machines: Siemens 18 MV, Varian 15 MV, and Varian 18 MV. The linac head components are simulated in detail. The dose distributions from photons, neutrons, protons, and alpha particles are calculated in a tissue-equivalent phantom. Neutrons are generated in both the linac head and the phantom. This study includes (a) field size effects, (b) off-axis dose profiles, (c) neutron contribution from the linac head, (d) dose contribution from capture gamma rays, (e) phantom heterogeneity effects, and (f) effects of primary electron energy shift. Results are presented in terms of absolute dose distributions and also in terms of DER (dose equivalent ratio). The DER is the maximum dose from the particle (neutron, proton, or alpha) divided by the maximum photon dose, multiplied by the particle quality factor and the modulation scaling factor. The total DER including neutrons, protons, and alphas is about 0.66 cSv/Gy for the Siemens 18 MV beam (10 cm x 10 cm). The neutron DER decreases with decreasing field size while the proton (or alpha) DER does not vary significantly except for the 1 cm x 1 cm field. Both Varian beams (15 and 18 MV) produce more neutrons, protons, and alphas particles than the Siemens 18 MV beam. This is mainly due to their higher primary electron energies: 15 and 18.3 MeV, respectively, vs 14 MeV for the Siemens 18 MV beam. For all beams, neutrons contribute more than 75% of the total DER, except for the 1 cm x 1 cm field (approximately 50%). The total DER is 1.52 and 2.86 cSv/Gy for the 15 and 18 MV Varian beams (10 cm x 10 cm), respectively. Media with relatively high-Z elements like bone may increase the dose from heavy charged particles by a factor 4. The total DER is sensitive to

  8. High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Demanes, D. Jeffrey, E-mail: jdemanes@mednet.ucla.edu [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, CA (United States); Martinez, Alvaro A.; Ghilezan, Michel [William Beaumont Hospital, Royal Oak, MI (United States); Hill, Dennis R.; Schour, Lionel; Brandt, David [California Endocurietherapy, Oakland, CA (United States); Gustafson, Gary [William Beaumont Hospital, Royal Oak, MI (United States)

    2011-12-01

    Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography-defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis-free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

  9. Optically erasable samarium-doped fluorophosphate glasses for high-dose measurements in microbeam radiation therapy

    Science.gov (United States)

    Morrell, B.; Okada, G.; Vahedi, S.; Koughia, C.; Edgar, A.; Varoy, C.; Belev, G.; Wysokinski, T.; Chapman, D.; Sammynaiken, R.; Kasap, S. O.

    2014-02-01

    Previous work has demonstrated that fluorophosphate (FP) glasses doped with trivalent samarium (Sm3+) can be used as a dosimetric detector in microbeam radiation therapy (MRT) to measure high radiation doses and large dose variations with a resolution in the micrometer range. The present work addresses the use of intense optical radiation at 405 nm to erase the recorded dose information in Sm3+-doped FP glass plates and examines the underlying physics. We have evaluated both the conversion and optical erasure of Sm3+-doped FP glasses using synchrotron-generated high-dose x-rays at the Canadian Light Source. The Sm-ion valency conversion is accompanied by the appearance of x-ray induced optical absorbance due to the trapping of holes and electrons into phosphorus-oxygen hole (POHC) and electron (POEC) capture centers. Nearly complete Sm2+ to Sm3+ reconversion (erasure) may be achieved by intense optical illumination. Combined analysis of absorbance and electron spin resonance measurements indicates that the optical illumination causes partial disappearance of the POHC and the appearance of new POEC. The suggested model for the observed phenomena is based on the release of electrons during the Sm2+ to Sm3+ reconversion process, the capture of these electrons by POHC (and hence their disappearance), or by PO groups, with the appearance of new and/or additional POEC. Optical erasure may be used as a practical means to erase the recorded data and permits the reuse of these Sm-doped FP glasses in monitoring dose in MRT.

  10. High-dose therapy improved the bone remodelling compartment canopy and bone formation in multiple myeloma

    DEFF Research Database (Denmark)

    Hinge, Maja; Delaissé, Jean-Marie; Plesner, Torben;

    2015-01-01

    . Loss of this canopy has been associated with bone loss. This study addresses whether the bone remodelling in MM is improved by high-dose therapy. Bone marrow biopsies obtained from 20 MM patients, before and after first-line treatment with high-dose melphalan followed by autologous stem cell...... transplantation, and from 20 control patients with monoclonal gammopathy of undetermined significance were histomorphometrically investigated. This investigation confirmed that MM patients exhibited uncoupled bone formation to resorption and reduced canopy coverage. More importantly, this study revealed......Bone loss in multiple myeloma (MM) is caused by an uncoupling of bone formation to resorption trigged by malignant plasma cells. Increasing evidence indicates that the bone remodelling compartment (BRC) canopy, which normally covers the remodelling sites, is important for coupled bone remodelling...

  11. An abbreviated repeat dose and reproductive/developmental toxicity test for high production volume chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Scala, R.A.; Bevan, C.; Beyer, B.K. (Exxon Biomedical Sciences, Inc., East Millstone, NJ (United States))

    1992-08-01

    A novel protocol is described for obtaining preliminary data on repeated dose systemic effects and reproductive/developmental toxicity. The test protocol was developed by a group of experts at the request of the U.S. Environmental Protection Agency (EPA) for use as part of a Screening Information Data Set on high production volume chemicals. Interest in this protocol is shared by several regulatory agencies, including the Organization for Economic Cooperation, the European Community, and the EPA. To validate the study protocol, ethylene glycol monomethyl ether (EGME) was used. After a dosing period of approximately 6 weeks, EGME showed both systemic and reproductive/developmental effects similar to those previously reported using standard protocols. Thus, this test protocol may be used as a screening tool for high production volume chemicals.

  12. Simulation two-beam high-dose ion implantation in solid-state targets

    CERN Document Server

    Komarov, A F

    2001-01-01

    The physicomathematical model and the program on the BEAM2HD dynamic modeling make it possible to model the process of the single- or two-beam high-dose ion implantation into the multilayer and multicomponent targets, is developed. The number of layer thereby does not exceed three and the number of various types of atoms in each layer does not exceed seven. The modeling is realized through the Monte-Carlo method. The numerical results of the work on formation of the C sub x sub-> sub 3 N sub y sub-> sub 4 supersolid layers through the nitrogen two-beam high-dose ion implantation into the Si sub 3 N sub 4 /C/Si sub 3 N sub 4 /Si multilayer system are presented

  13. Double Dose: High Family Conflict Enhances the Effect of Media Violence Exposure on Adolescents’ Aggression

    Directory of Open Access Journals (Sweden)

    Patti M. Valkenburg

    2013-07-01

    Full Text Available We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low conflict families. A total of 499 adolescents (aged 10 to 14, 48% girls participated in a two-wave longitudinal survey (4-month interval. Survey questions assessed their exposure to violence on television and in electronic games, family conflict, and aggressive behavior. Analyses revealed a significant interaction between media violence and family conflict. In families with higher conflict, higher media violence exposure was related to increased subsequent aggression. This study is the first to show a double dose effect of media violence and family conflict on adolescents’ aggression. These findings underscore the important role of the family in shaping the effects of adolescents’ media use on their social development.

  14. HIGH-DOSE BIOTIN TREATMENT FOR SECONDARY PROGRESSIVE MULTIPLE SCLEROSIS MAY INTERFERE WITH THYROID ASSAYS.

    Science.gov (United States)

    Minkovsky, Alissa; Lee, Mark N; Dowlatshahi, Mitra; Angell, Trevor E; Mahrokhian, Lilian S; Petrides, Athena K; Melanson, Stacy E F; Marqusee, Ellen; Woodmansee, Whitney W

    2016-01-01

    To review cases and increase awareness in clinicians treating patients who may be taking biotin. We describe the presentation and workup of a woman with secondary progressive multiple sclerosis on high dose biotin with laboratory studies suggestive of thyrotoxicosis. Plasma samples showed laboratory evidence of elevated thyroid hormone levels with elevated free thyroxine >7.8 ng/dl (reference interval (RI) 0.9-1.7 ng/dl) and decreased thyroid stimulating hormone <0.02 uIU/ml (RI 0.50-5.70 uIU/ml). Laboratory values normalized when biotin was withheld prior to repeat testing. Our case report demonstrates that ingestion of high dose biotin in multiple sclerosis patients can cause interference with laboratory assessment of thyroid function. This interference causes laboratory values suggestive of thyrotoxicosis and can lead to unnecessary evaluation. Clinicians should be aware of the risk of laboratory interference in this patient demographic.

  15. Heavy ion time-of-flight ERDA of high dose metal implanted germanium

    Energy Technology Data Exchange (ETDEWEB)

    Dytlewski, N.; Evans, P.J.; Noorman, J.T. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Wielunski, L.S. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Lindfield, NSW (Australia). Div. of Applied Physics; Bunder, J. [New South Wales Univ., Wollongong, NSW (Australia). Wollongong Univ. Coll

    1996-12-31

    With the thick Ge substrates used in ion implantation, RBS can have difficulty in resolving the mass-depth ambiguities when analysing materials composed of mixtures of elements with nearly equal masses. Additional, and complimentary techniques are thus required. This paper reports the use of heavy ion time-of-flight elastic recoil detection analysis (ToF- ERDA), and conventional RBS in the analysis of Ge(100) implanted with high dose Ti and Cu ions from a MEWA ion source . Heavy ion ToF ERDA has been used to resolve, and profile the implanted transition metal species, and also to study any oxygen incorporation into the sample resulting from the implantation, or subsequential reactions with air or moisture. This work is part of a study on high dose metal ion implantation of medium atomic weight semiconductor materials. 13 refs., 6 figs.

  16. High-dose chemoradiotherapy and watchful waiting for distal rectal cancer

    DEFF Research Database (Denmark)

    Appelt, Ane L; Pløen, John; Harling, Henrik

    2015-01-01

    BACKGROUND: Abdominoperineal resection is the standard treatment for patients with distal T2 or T3 rectal cancers; however, the procedure is extensive and mutilating, and alternative treatment strategies are being investigated. We did a prospective observational trial to assess whether high-dose...... radiotherapy with concomitant chemotherapy followed by observation (watchful waiting) was successful for non-surgical management of low rectal cancer. METHODS: Patients with primary, resectable, T2 or T3, N0-N1 adenocarcinoma in the lower 6 cm of the rectum were given chemoradiotherapy (60 Gy in 30 fractions......-0) at all timepoints. The most common late toxicity was bleeding from the rectal mucosa; grade 3 bleeding was reported in two (7%) in 30 patients at 1 year and one (6%) of 17 patients at 2 years. There were no unexpected serious adverse reactions or treatment-related deaths. INTERPRETATION: High-dose...

  17. Calcium antagonist in the treatment of symptomatic dermographism. Low-dose and high-dose studies with nifedipine.

    Science.gov (United States)

    Lawlor, F; Ormerod, A D; Greaves, M W

    1988-01-01

    The effect of nifedipine on subjective symptoms and objective dermographometer induced whealing was assessed independently in two double-blind cross-over trials in which active drug or placebo were taken for 2 weeks. The lower dose study used nifedipine 5 mg 3 times daily and gave rise to symptomatic improvement as assessed by diary card and visual analogue scale in 5 of 11 patients. This was not statistically significant and was not accompanied by a reduction in dermographometer-induced wheal and flare responses except at highest pressures. In a separate study 7 patients were treated with nifedipine 10 mg 3 times daily. No change in whealing occurred, 3 patients' symptoms became worse and only 1 showed symptomatic improvement on nifedipine. Side effects were frequent at this dose. The reasons for the unfavourable response despite in vitro evidence for inhibition of mast cell degranulation by this drug are discussed.

  18. Performance assessment of the BEBIG MultiSource high dose rate brachytherapy treatment unit.

    Science.gov (United States)

    Palmer, Antony; Mzenda, Bongile

    2009-12-21

    A comprehensive system characterisation was performed of the Eckert & Ziegler BEBIG GmbH MultiSource High Dose Rate (HDR) brachytherapy treatment unit with an (192)Ir source. The unit is relatively new to the UK market, with the first installation in the country having been made in the summer of 2009. A detailed commissioning programme was devised and is reported including checks of the fundamental parameters of source positioning, dwell timing, transit doses and absolute dosimetry of the source. Well chamber measurements, autoradiography and video camera analysis techniques were all employed. The absolute dosimetry was verified by the National Physical Laboratory, UK, and compared to a measurement based on a calibration from PTB, Germany, and the supplied source certificate, as well as an independent assessment by a visiting UK centre. The use of the 'Krieger' dosimetry phantom has also been evaluated. Users of the BEBIG HDR system should take care to avoid any significant bend in the transfer tube, as this will lead to positioning errors of the source, of up to 1.0 mm for slight bends, 2.0 mm for moderate bends and 5.0 mm for extreme curvature (depending on applicators and transfer tube used) for the situations reported in this study. The reason for these errors and the potential clinical impact are discussed. Users should also note the methodology employed by the system for correction of transit doses, and that no correction is made for the initial and final transit doses. The results of this investigation found that the uncorrected transit doses lead to small errors in the delivered dose at the first dwell position, of up to 2.5 cGy at 2 cm (5.6 cGy at 1 cm) from a 10 Ci source, but the transit dose correction for other dwells was accurate within 0.2 cGy. The unit has been mechanically reliable, and source positioning accuracy and dwell timing have been reproducible, with overall performance similar to other existing HDR equipment. The unit is capable of high

  19. Effect of high gamma-doses in the sensitization of natural quartz for thermoluminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Khoury, H.J.; Guzzo, P.L.; Brito, S.B. [Universidade Federal de Pernambuco, 50740-540 Recife PE (Brazil)

    2006-07-01

    Sensitization is an important effect in radiation dosimetry using thermoluminescent (TL materials where the enhancement of sensitivity is a desirable feature. Until known, the investigation of sensitization in quartz has been restricted to its first glow peak appearing around 110 C. In addition, the sensitization process has been essentially produced by heat-treatments in powdered quartz. The aim of this study is to investigate the sensitization process in the second glow peak of crystalline quartz using high doses of gamma irradiation. For this, five lots of samples were prepared from quartz single crystals issued from different geologies in Brazil. Chips of 5 x 5 x 1 mm{sup 3} (60 mg) were cut and lapped parallel to the (0001) plane. The specimens were initially irradiated with doses of gamma radiation of {sup 137} Cs in the range of 10 mGy to 10 Gy in order to determine its TL response curve. After that, the specimens were submitted to successive high doses of gamma-irradiation with {sup 60} Co from 25 kGy to 350 kGy. After each irradiation, the TL response curves to gamma radiation of {sup 137} Cs were determined for each quartz lot irradiated in the range of 2 to 20 mGy. The TL measurements were carried out with a 2800M Victoreen reader using the step mode. The step parameters were set in 10 s from 30 to 160 C (first region) and in 20 s from 160 to 320 C (second region). The absolute TL signal used to obtain the calibration curves represented the sum of electric charges under the glow peak appearing in the second region. The results showed that the TL response of the quartz studied increased with the dose sensitization, so that the TL response for 10mGy of {sup 137} Cs radiation varied from 0.05 nC/mg for the quartz without sensitization to 10 nC/mg after a sensitization with 50 kGy of gamma radiation of {sup 60} Co. The effect of sensitization with high doses of gamma irradiation was clearly observed for three quartz lots and it was observed that the high

  20. Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization

    Energy Technology Data Exchange (ETDEWEB)

    Gay, H A [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Allison, R R [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Downie, G H [Section of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Mota, H C [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Austerlitz, C [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Jenkins, T [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States); Sibata, C H [Department of Radiation Oncology, Brody School of Medicine at East Carolina University, Greenville, NC (United States)

    2007-06-07

    A number of patients with lung cancer receive either palliative or curative high-dose-rate (HDR) endobronchial brachytherapy. Up to a third of patients treated with endobronchial HDR die from hemoptysis. Rather than accept hemoptysis as an expected potential consequence of HDR, we have calculated the radial dose distribution for an Ir-192 HDR source, rigorously examined the dose and prescription points recommended by the American Brachytherapy Society (ABS), and performed a radiobiological-based analysis. The radial dose rate of a commercially available Ir-192 source was calculated with a Monte Carlo simulation. Based on the linear quadratic model, the estimated palliative, curative and blood vessel rupture radii from the center of an Ir-192 source were obtained for the ABS recommendations and a series of customized HDR prescriptions. The estimated radius at risk for blood vessel perforation for the ABS recommendations ranges from 7 to 9 mm. An optimized prescription may in some situations reduce this radius to 4 mm. The estimated blood perforation radius is generally smaller than the palliative radius. Optimized and individualized endobronchial HDR prescriptions are currently feasible based on our current understanding of tumor and normal tissue radiobiology. Individualized prescriptions could minimize complications such as fatal hemoptysis without sacrificing efficacy. Fiducial stents, HDR catheter centering or spacers and the use of CT imaging to better assess the relationship between the catheter and blood vessels promise to be useful strategies for increasing the therapeutic index of this treatment modality. Prospective trials employing treatment optimization algorithms are needed.

  1. High dose of maternal folic acid supplementation is associated to infant asthma.

    Science.gov (United States)

    Yang, Liu; Jiang, Liwen; Bi, Meirong; Jia, Xiaodong; Wang, Youqing; He, Chuan; Yao, Yao; Wang, Jun; Wang, Zhiping

    2015-01-01

    Maternal folic acid supplementation had a positive effect on preventing neural tube defects (NTDs), but its effects in infant asthma remained unclear. A hospital-based case-control study was conducted with outpatients between March 2010 and March 2011 including 150 onset infant asthma cases and 212 controls, together with a meta-analysis involving 14,438 participants, was performed. The association between maternal folic acid supplementation and the risk of infant asthma was not significant either in the meta-analysis (OR = 1.06, 95% CI =0.99-1.14) or in the case-control study (OR = 0.72, 95% CI =0.37-1.39). However, quantitative analysis of the supplementation dose demonstrated that the risk of infant asthma significantly increased for the infants whose mother were with high-dose supplementation (>72,000 µg•d; OR = 3.16, 95% CI =1.15-8.71) after adjusting for confounding factors in the case-control study. Meanwhile, the risk of infant asthma significantly decreased for the infants whose mother were with low-dose supplementation (folic acid supplementation for mother during pregnancy was associated with an increased risk of infant asthma, whereas supplementation with a relatively low-dose was associated with a decreased risk of infant asthma. These findings should be further investigated in a large population.

  2. Efficacy of a single high oxfendazole dose against gastrointestinal nematodes in naturally infected pigs.

    Science.gov (United States)

    Alvarez, Luis; Saumell, Carlos; Fusé, Luis; Moreno, Laura; Ceballos, Laura; Domingue, Gilbert; Donadeu, Meritxell; Dungu, Baptiste; Lanusse, Carlos

    2013-05-01

    The goal of the current experiment was to assess the clinical efficacy of oxfendazole (OFZ) administered as a single oral dose (30 mg/kg) to pigs naturally parasitized with Ascaris suum, Oesophagostomum spp., Metastrongylus spp. and Trichuris suis. Thirty-six local ecotype piglets were divided into three independent experiments, named I, II and III (n=12 each), respectively. Each experiment involved two different groups (n=6): Untreated Control and OFZ treated. Animals were naturally parasitized with A. suum (Experiments I, II and III), Oesophagostomum spp. (Experiments I and II), T. suis (Experiments II and III) and Metastrongylus spp. (Experiment I). Pigs in the treated group received OFZ (Synanthic(®), Merial Ltd., 9.06% suspension) orally at 30 mg/kg dose. At five (5) days post-treatment, animals were sacrificed and the clinical efficacy of the OFZ treatment was established following the currently available WAAVP guidelines for a controlled efficacy test. None of the animals involved in this experiment showed any adverse events during the study. OFZ treatment given as a single 30 mg/kg oral dose showed a 100% efficacy against all the nematode parasites present in the three experiments. In conclusion, under the current experimental conditions, OFZ orally administered to naturally parasitized piglets at a single dose of 30 mg/kg was safe and highly efficacious (100%) against adult stages of A. suum, Oesophagostomum spp., T. suis and Metastrongylus spp.

  3. High-dose weekly fractionation radiotherapy in advanced cancer of the uterine cervix

    Energy Technology Data Exchange (ETDEWEB)

    Browde, S.; Nissenbaum, M.; De Moor, N.G. (University of the Witwatersrand, Johannesburg (South Africa))

    1984-07-07

    A trial comparing two different radiotherapy techniques and schedules is the treatment of 83 patients with advanced cancer of the uterine cervix (stage IIIB) employing external irradiation alone is described. The one technique, used routinely in this department, employed a conventional daily fractionation schedule while the other used a high-dose weekly fractionation regimen. The techniques are described. The aim of the trial was to compare the efficacy and morbidity of these two methods of treatment. Dose distribution curves in cross-section and midsagittal planes are shown and calculations or equivalent doses at various selected points using Ellis's nominal single-dose formula are tabulated. The 2-year survival figures were 33% for the daily fractionation technique and 22% for the weekly regimen. Serious late complication rates were 6% for the daily regimen and 22% for the weekly schedule. These differences are not statistically significant. Late complication rates in the weekly fractionation regimen appeared to be lower than figures quoted by other authors. Local control within the irradiated volume was better in the group treated by the daily fractionation method.

  4. High Dose of Lamivudine and Resistance in Patients with Chronic Hepatitis B

    Directory of Open Access Journals (Sweden)

    Hamid Ullah Wani

    2014-01-01

    Full Text Available Background. Lamivudine is the most affordable drug used for chronic hepatitis B and has a high safety profile. With the daily dose of 100 mg there is progressive appearance of resistance to lamivudine therapy. In our study we used 150 mg of lamivudine daily as a standard dose which warrants further exploration for the efficacy of the drug. Aims of the Study. To assess the efficacy of lamivudine 150 mg daily on resistance in patients with chronic hepatitis B. Methods. This retrospective study consists of 53 patients with chronic hepatitis B treated with 150 mg of lamivudine daily. The biochemical and virological response to the treatment were recorded at a 1-year and 2-, 3-, 4-, and 5-year period and time of emergence of resistance to the treatment was noted. Results. The mean age of the patients was 54 years with 80% being males. The resistance to lamivudine 150 mg daily at 1 year and 2, 3, and 5 years was 12.5%, 22.5%, 37.5%, and 60%, respectively, which is much less compared to the standard dose of 100 mg of lamivudine. Conclusions. Lamivudine is safe and a higher dose of 150 mg daily delays the resistance in patients with chronic hepatitis B.

  5. High Dose of Lamivudine and Resistance in Patients with Chronic Hepatitis B

    Science.gov (United States)

    Wani, Hamid Ullah; Al Kaabi, Saad; Singh, Rajvir; John, Anil; Derbala, Moutaz; Al-Mohannadi, Muneera J.

    2014-01-01

    Background. Lamivudine is the most affordable drug used for chronic hepatitis B and has a high safety profile. With the daily dose of 100 mg there is progressive appearance of resistance to lamivudine therapy. In our study we used 150 mg of lamivudine daily as a standard dose which warrants further exploration for the efficacy of the drug. Aims of the Study. To assess the efficacy of lamivudine 150 mg daily on resistance in patients with chronic hepatitis B. Methods. This retrospective study consists of 53 patients with chronic hepatitis B treated with 150 mg of lamivudine daily. The biochemical and virological response to the treatment were recorded at a 1-year and 2-, 3-, 4-, and 5-year period and time of emergence of resistance to the treatment was noted. Results. The mean age of the patients was 54 years with 80% being males. The resistance to lamivudine 150 mg daily at 1 year and 2, 3, and 5 years was 12.5%, 22.5%, 37.5%, and 60%, respectively, which is much less compared to the standard dose of 100 mg of lamivudine. Conclusions. Lamivudine is safe and a higher dose of 150 mg daily delays the resistance in patients with chronic hepatitis B. PMID:25349729

  6. High dose of Lamivudine and resistance in patients with chronic hepatitis B.

    Science.gov (United States)

    Wani, Hamid Ullah; Al Kaabi, Saad; Sharma, Manik; Singh, Rajvir; John, Anil; Derbala, Moutaz; Al-Mohannadi, Muneera J

    2014-01-01

    Background. Lamivudine is the most affordable drug used for chronic hepatitis B and has a high safety profile. With the daily dose of 100 mg there is progressive appearance of resistance to lamivudine therapy. In our study we used 150 mg of lamivudine daily as a standard dose which warrants further exploration for the efficacy of the drug. Aims of the Study. To assess the efficacy of lamivudine 150 mg daily on resistance in patients with chronic hepatitis B. Methods. This retrospective study consists of 53 patients with chronic hepatitis B treated with 150 mg of lamivudine daily. The biochemical and virological response to the treatment were recorded at a 1-year and 2-, 3-, 4-, and 5-year period and time of emergence of resistance to the treatment was noted. Results. The mean age of the patients was 54 years with 80% being males. The resistance to lamivudine 150 mg daily at 1 year and 2, 3, and 5 years was 12.5%, 22.5%, 37.5%, and 60%, respectively, which is much less compared to the standard dose of 100 mg of lamivudine. Conclusions. Lamivudine is safe and a higher dose of 150 mg daily delays the resistance in patients with chronic hepatitis B.

  7. Retraction of colonies and structures of Aspergillus Spp. as a possible high dose sensor

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Valeria B., E-mail: valeriabborges@hotmail.com [Coordenacao dos Programas de Pos-Graduacao em Processos Quimicos e Bioquimicos (EQ/UFRJ), Rio de Janeiro, RJ (Brazil). Escola de Quimica; Vital, Helio C., E-mail: vital@ctex.eb.br [Centro Tecnologico do Exercito (DDQBN/CTEx), Rio de Janeiro, RJ (Brazil). Div. de Defesa Quimica, Biologica e Nuclear. Secao de Defesa Nuclear; Moraes, Aurea M.L., E-mail: ltbbf@ioc.fiocruz.br [Instituto Oswaldo Cruz (FIOCRUZ), Rio de Janeiro, RJ (Brazil). Departamento de Micologia

    2013-07-01

    Changes in the length of macro-and microscopic structures of irradiated Aspergillus spp. colonies were investigated in this work in search for correlations with radiation dose. Effects related to growth and morphology produced by exposure to radiation doses ranging from 0.0 up to 8.0 kGy on strains of A. flavus (CMT 00079), A. parasiticus (CMT 00064) and A ochraceus (CMT 00145) were analyzed. Fungal colonies were inoculated on fresh peanut seeds and incubated for 5 days at 25°C. On the sixth day the samples were irradiated and moved to Petri dishes containing PDA culture medium where they remained incubated for 7 days at 25°C Post irradiation growth was periodically monitored by visual inspections and measurements of mycelial diameters. In addition, microscopic analyses were performed to determine the length of the major structures of the colonies. It has been found that irradiation causes a decrease in the diameter of colonies as well as in the length of microscopic structures of the fungus. The amount of retraction has been found to be strongly correlated to radiation dose. Such findings hint at the possibility of using in situ Aspergillus spp. colonies as high-dose living dosimeters in the event of massive radiation exposures. (author)

  8. Time-dose relationship of erythema in high energy photon irradiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hidetoshi (Gifu Prefectural Tajimi Hospital (Japan)); Sakuma, Sadayuki

    1992-01-01

    Skin doses of 100 patients who were treated with high energy ionizing irradiation during conventional irradiation therapy were measured by thermoluminescence dosimeter (TLD). In 87 of the 100 patients, acute hyperemic change of the skin (erythema) of the irradiated region was observed. In the other 13 patients, alopetia of the scalp was observed. The following conclusions were reached. The time-dose relationship was linear when erythema tolerance was used as an index, but not when alopecia was used. The tolerance dose for erythema was lower than previously reported. The slope of the isoeffect curve on the log-log plot of total absorbed skin dose against total number of days after the first irradiation was 0.68 when erythema was used as an index. This number is larger than previously reported results. We considered that erythema is significantly influenced by fraction size and that hyperfractionation is a promising method of irradiation, especially in Japan. Combined use of chemotherapeutic agents, such as 5-FU, accelerated erythema. The slope of combined treatment was 0.86. Observing acute hyperemic change of skin is considered to be a useful method of investigating the combined effects of chemotherapeutic agents on irradiation. (author).

  9. The use of very high-doses of baclofen for the treatment of alcohol-dependence: a case series.

    Directory of Open Access Journals (Sweden)

    Renaud ede Beaurepaire

    2014-10-01

    Full Text Available Baclofen, particularly high-dose baclofen, has recently emerged as a treatment of major interest for alcohol-dependence. However, baclofen has many potentially dangerous side effects, and the maximal dose of baclofen that may be used is a matter of discussion. Here, the author analyses the medical charts of the last 100 patients seen in his clinic, 17 of whom have been taking a very high dose of baclofen, that is to say, more than 300mg per day. The analysis of the charts shows that the very high doses baclofen were justified in almost all the cases. Side effects are analyzed.

  10. High-dose rate brachytherapy in the treatment of cancer of the cervix uteri

    Directory of Open Access Journals (Sweden)

    D. A. Aliyev

    2011-01-01

    Full Text Available Analysis of the results of examining and treating 246 patients with Stages IIA-IIIB cancer of the cervix uteri (CCU, receiving specific chemoradiotherapy (CRT at the Department of Radiotherapy, National Oncology Center (Baku, has ascertained that CRT using two high-dose (9 Gy rate brachytherapy fractions and competitive cisplatin chemotherapy is an effective, reasonably safe, and economically sound treatment method for locally advanced CCU. The method shows acceptable toxicity and may be used in routine clinical practice.

  11. Low-dose insulin infusions in diabetic patients with high insulin requirements.

    Science.gov (United States)

    Dandona, P; Foster, M; Healey, F; Greenbury, E; Beckett, A G

    1978-08-01

    Six patients with high insulin requirements (range 120-3000 units daily) have been infused with much smaller doses (range 50-63 units daily) of insulin intravenously. All six maintained adequate glucose homoestasis on this regimen. It is suggested that subcutaneous tissue at the site of injection may alter insulin or impair its absorption. Insulin resistance in some patients may be due to these mechanisms.

  12. Effect of high-dose preoperative methylprednisolone on recovery after total hip arthroplasty

    DEFF Research Database (Denmark)

    Lunn, T H; Andersen, Lasse Østergaard; Kristensen, B B

    2013-01-01

    BACKGROUND: /st>High-dose glucocorticoid may reduce postsurgical pain and improve recovery. We hypothesized that 125 mg methylprednisolone (MP) would reduce time to meet functional discharge criteria after total hip arthroplasty (THA). METHODS: /st>Forty-eight patients undergoing unilateral THA...... well-defined functional discharge criteria. Secondary outcomes were handgrip strength and endurance, pain, nausea, vomiting, fatigue, sleep quality, and rescue analgesic-, antiemetic-, and hypnotic medicine requirements. The inflammatory response measured by C-reactive protein (CRP) and actual length...

  13. Primary treatment of acromegaly with high-dose lanreotide: a case series

    OpenAIRE

    Cordes Uwe; Both Stefan; Wuster Christian; Omran Wael; Reisch Robert

    2010-01-01

    Abstract Introduction The first-line treatment for acromegaly is transsphenoidal surgery. In approximately 50% of patients, however, a cure is not possible with surgery and alternatives are needed. Somatostatin analog therapy is the recommended first-line treatment in patients with such cases. Here we provide the first report of a high-dose lanreotide primary therapy in patients with acromegaly. Case presentation Six patients who were not suitable for surgery were given 60 mg of lanreotide (A...

  14. Mechanical Performance of Ferritic Martensitic Steels for High Dose Applications in Advanced Nuclear Reactors

    Science.gov (United States)

    Anderoglu, Osman; Byun, Thak Sang; Toloczko, Mychailo; Maloy, Stuart A.

    2013-01-01

    Ferritic/martensitic (F/M) steels are considered for core applications and pressure vessels in Generation IV reactors as well as first walls and blankets for fusion reactors. There are significant scientific data on testing and industrial experience in making this class of alloys worldwide. This experience makes F/M steels an attractive candidate. In this article, tensile behavior, fracture toughness and impact property, and creep behavior of the F/M steels under neutron irradiations to high doses with a focus on high Cr content (8 to 12) are reviewed. Tensile properties are very sensitive to irradiation temperature. Increase in yield and tensile strength (hardening) is accompanied with a loss of ductility and starts at very low doses under irradiation. The degradation of mechanical properties is most pronounced at reactor environment, the stress exponent is expected to be approximately one and the steady state creep rate in the absence of swelling is usually better than austenitic stainless steels both in terms of the creep rate and the temperature sensitivity of creep. In short, F/M steels show excellent promise for high dose applications in nuclear reactors.

  15. High dose folic acid supplementation in women with epilepsy: are we sure it is safe?

    Science.gov (United States)

    Asadi-Pooya, Ali A

    2015-04-01

    Most experts agree that folic acid supplementation is a key preconception intervention, particularly in women with epilepsy who take anti-epileptic drugs (AEDs). Primary prevention of neural tube defect through folic acid supplementation results in reduction of risk in an otherwise healthy population. The current folic acid supplementation recommendation is that all women of childbearing potential be supplemented with at least 0.4 mg of folic acid daily prior to conception and during pregnancy. It is recommended that all women with epilepsy and of childbearing potential be supplemented with folic acid daily prior to conception and during pregnancy. However, considering the potential significant drug-drug interactions between high doses of folic acid and some AEDs in patients with epilepsy and also with the emerging evidence from animal studies that high levels of folic acid throughout gestation may have adverse effects on fetal brain development, it is not suggested to advocate high dose folic acid supplementation in women with epilepsy until more information is available about its appropriate, safe and optimal dosing.

  16. High-dose steroid therapy for idiopathic optic perineuritis: a case series

    Directory of Open Access Journals (Sweden)

    Mimura Tatsuya

    2010-12-01

    Full Text Available Abstract Introduction It has been reported that the prognosis of optic perineuritis may be poor when initiation of treatment is delayed. Here we report the successful treatment of three patients with idiopathic optic perineuritis, including two in whom initiation of therapy was delayed. Case presentation Three Japanese patients (two women aged 73 and 66 years, and one man aged 27 years presented with loss of vision (for five months, several months, and two months respectively and pain on eye movement in the third case only, and were diagnosed as having idiopathic optic perineuritis. Fat-suppressed T2-weighted magnetic resonance images showed high signal intensity areas around the affected optic nerves, suggesting the presence of optic perineuritis. Two patients received steroid pulse therapy and the third was given high-dose steroid therapy. The visual acuity improved in all three cases. Conclusion High-dose steroid therapy may be effective for idiopathic perineuritis in patients without optic nerve atrophy, even if initial treatment (including moderate-dose steroids has failed.

  17. Dose protraction studies with low- and high-LET radiations on neoplastic cell transformation in vitro

    Science.gov (United States)

    Yang, Tracy Chui-Hsu; Craise, Laurie M.; Tobias, Cornelius A.; Mei, Man-Tong

    1986-01-01

    The effects of the low- and high-LET radiation (by X-rays, Co-60, and heavy ions) on the transformation of neoplastic cells were studied using cultured C3H10T1/2 mouse embryo cells. The transformed colonies in the confluent cell monolayers were recognized as focuses composed of highly polar fibroblastic multilayered criss-cross arrays of densely stained cells. For the low-LET radiation, there was a decrease in cell killing and cell transformation frequency when cells were irradiated with fractionated doses and at a low dose rate, indicating that cultured mammalian cells can repair both subtransformation and potential transformation lesions. No sparing effect, however, was found for the high-LET radiation. An enhancement of cell transformation was observed for low-dose/rate argon (400 MeV/u; 120 keV/micron) and iron particles (600 MeV/u; 200 keV/micron). The molecular mechanism for this enhancement effect is not known.

  18. Dose protraction studies with low- and high-LET radiations on neoplastic cell transformation in vitro

    Science.gov (United States)

    Yang, Tracy Chui-Hsu; Craise, Laurie M.; Tobias, Cornelius A.; Mei, Man-Tong

    1986-01-01

    The effects of the low- and high-LET radiation (by X-rays, Co-60, and heavy ions) on the transformation of neoplastic cells were studied using cultured C3H10T1/2 mouse embryo cells. The transformed colonies in the confluent cell monolayers were recognized as focuses composed of highly polar fibroblastic multilayered criss-cross arrays of densely stained cells. For the low-LET radiation, there was a decrease in cell killing and cell transformation frequency when cells were irradiated with fractionated doses and at a low dose rate, indicating that cultured mammalian cells can repair both subtransformation and potential transformation lesions. No sparing effect, however, was found for the high-LET radiation. An enhancement of cell transformation was observed for low-dose/rate argon (400 MeV/u; 120 keV/micron) and iron particles (600 MeV/u; 200 keV/micron). The molecular mechanism for this enhancement effect is not known.

  19. Optimal bladder filling during high-dose-rate intracavitary brachytherapy for cervical cancer: a dosimetric study

    Science.gov (United States)

    Shetty, Saurabha; Majumder, Dipanjan; Adurkar, Pranjal; Swamidas, Jamema; Engineer, Reena; Chopra, Supriya; Shrivastava, Shyamkishore

    2017-01-01

    Purpose The aim of this study is to compare 3D dose volume histogram (DVH) parameters of bladder and other organs at risk with different bladder filling protocol during high-dose-rate intracavitary brachytherapy (HDR-ICBT) in cervical cancer, and to find optimized bladder volume. Material and methods This dosimetric study was completed with 21 patients who underwent HDR-ICBT with computed tomography/magnetic resonance compatible applicator as a routine treatment. Computed tomography planning was done for each patient with bladder emptied (series 1), after 50 ml (series 2), and 100 ml (series 3) bladder filling with a saline infusion through the bladder catheter. Contouring was done on the Eclipse Planning System. 7 Gy to point A was prescribed with the standard loading patterns. Various 3D DVH parameters including 0.1 cc, 1 cc, 2 cc doses and mean doses to the OAR’s were noted. Paired t-test was performed. Results The mean (± SD) bladder volume was 64.5 (± 25) cc, 116.2 (± 28) cc, and 172.9 (± 29) cc, for series 1, 2, and 3, respectively. The 0.1 cm3,1 cm3, 2 cm3 mean bladder doses for series 1, series 2, and series 3 were 9.28 ± 2.27 Gy, 7.38 ± 1.72 Gy, 6.58 ± 1.58 Gy; 9.39 ± 2.28 Gy, 7.85 ± 1.85 Gy, 7.05 ± 1.59 Gy, and 10.09 ± 2.46 Gy, 8.33 ± 1.75 Gy, 7.6 ± 1.55 Gy, respectively. However, there was a trend towards higher bladder doses in series 3. Similarly, for small bowel dose 0.1 cm3, 1 cm3, and 2 cm3 in series 1, 2, and 3 were 5.44 ± 2.2 Gy, 4.41 ± 1.84 Gy, 4 ± 1.69 Gy; 4.57 ± 2.89 Gy, 3.78 ± 2.21 Gy, 3.35 ± 2.02 Gy, and 4.09 ± 2.38 Gy, 3.26 ± 1.8 Gy, 3.05 ± 1.58 Gy. Significant increase in small bowel dose in empty bladder (series 1) compared to full bladder (series 3) (p = 0.03) was noted. However, the rectal and sigmoid doses were not significantly affected with either series. Conclusions Bladder filling protocol with 50 ml and 100 ml was well tolerated and achieved a reasonably reproducible bladder volume during cervical

  20. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products; Sistemas dosimetricos de altas dosis, tasa de dosis y uniformidad de dosis en alimentos y producto medico

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, J.; Vivanco, M.; Castro, E., E-mail: jvargas@ipen.gob.pe [Instituto Peruano de Energia Nuclear, Av. Canada 1470, San Borja, Lima (Peru)

    2014-08-15

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  1. Development of Radiation Fusion Technology with Food Technology by the Application of High Dose Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Won; Kim, Jae Hun; Choi, Jong Il

    2010-04-15

    This study was studied to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering were developed. Irradiation condition to destroy radiation resistant food borne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources were developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not were developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin were developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam were introduced. Results from this research project, the followings are expected. (1) Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. (2) Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of food borne outbreaks. (3) Build of SPS/TBT system against imported products and acceleration of domestic product export

  2. Development of radiation fusion technology with food technology by the application of high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juwoon; Kim, Jaehun; Choi, Jongil; and others

    2012-04-15

    This study was performed to achieve stable food supply and food safety with radiation fusion technology as a preparation for food weaponization. Results at current stage are following: First, for the development of radiation and food engineering fusion technology using high dose irradiation, the effects of high dose irradiation on food components were evaluated. The combination treatment of irradiation with food engineering was developed. Irradiation condition to destroy radiation resistant foodborne bacteria were determined. Second, for the development of E-beam irradiation technology, the effects of radiation sources on food compounds, processing conditions, and food quality of final products were compared. Food processing conditions for agricultural/aquatic products with different radiation sources was developed and the domination of E-beam irradiation foods were determined. The physical marker for E-beam irradiated foods or not was developed. Third, for the fundamental researches to develop purposed foods to extreme environmental, ready-to-eat foods were developed using high dose irradiation. Food processing for export strategy foods such as process ginseng were developed. Food processing with irradiation to destroy mycotoxin and to inhibit production of mycotoxin was developed. Mathematical models to predict necessary irradiation doses and radiation sources were developed and validated. Through the fundamental researches, the legislation for irradiation approval on meat products, sea foods and dried sea foods, and use of E-beam was introduced. Results from this research project, the followings are expected. Improvement of customer acceptance and activation of irradiation technology by the use of various irradiation rays. Increase of indirect food productivity, and decrease of SOC and improvement of public health by prevention of foodborne outbreaks. Build of SPS/TBT system against imported products and acceleration of domestic product export. Systemized

  3. Cytoprotective responses in HaCaT keratinocytes exposed to high doses of curcumin.

    Science.gov (United States)

    Lundvig, Ditte M S; Pennings, Sebastiaan W C; Brouwer, Katrien M; Mtaya-Mlangwa, Matilda; Mugonzibwa, Emeria; Kuijpers-Jagtman, Anne Marie; Wagener, Frank A D T G; Von den Hoff, Johannes W

    2015-08-15

    Wound healing is a complex process that involves the well-coordinated interactions of different cell types. Topical application of high doses of curcumin, a plant-derived polyphenol, enhances both normal and diabetic cutaneous wound healing in rodents. For optimal tissue repair interactions between epidermal keratinocytes and dermal fibroblasts are essential. We previously demonstrated that curcumin increased reactive oxygen species (ROS) formation and apoptosis in dermal fibroblasts, which could be prevented by pre-induction of the cytoprotective enzyme heme oxygenase (HO)-1. To better understand the effects of curcumin on wound repair, we now assessed the effects of high doses of curcumin on the survival of HaCaT keratinocytes and the role of the HO system. We exposed HaCaT keratinocytes to curcumin in the presence or absence of the HO-1 inducers heme (FePP) and cobalt protoporphyrin (CoPP). We then assessed cell survival, ROS formation, and caspase activation. Curcumin induced caspase-dependent apoptosis in HaCaT keratinocytes via a ROS-dependent mechanism. Both FePP and CoPP induced HO-1 expression, but only FePP protected against curcumin-induced ROS formation and caspase-mediated apoptosis. In the presence of curcumin, FePP but not CoPP induced the expression of the iron scavenger ferritin. Together, our data show that the induction of ferritin, but not HO, protects HaCaT keratinocytes against cytotoxic doses of curcumin. The differential response of fibroblasts and keratinocytes to high curcumin doses may provide the basis for improving curcumin-based wound healing therapies. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Cancer-associated fibroblasts from lung tumors maintain their immunosuppressive abilities after high-dose irradiation.

    Science.gov (United States)

    Gorchs, Laia; Hellevik, Turid; Bruun, Jack-Ansgar; Camilio, Ketil-Andre; Al-Saad, Samer; Stuge, Tor-Brynjar; Martinez-Zubiaurre, Inigo

    2015-01-01

    Accumulating evidence supports the notion that high-dose (>5 Gy) radiotherapy (RT) regimens are triggering stronger pro-immunogenic effects than standard low-dose (2 Gy) regimens. However, the effects of RT on certain immunoregulatory elements in tumors remain unexplored. In this study, we have investigated the effects of high-dose radiotherapy (HD-RT) on the immunomodulating functions of cancer-associated fibroblasts (CAFs). Primary CAF cultures were established from lung cancer specimens derived from patients diagnosed for non-small cell lung cancer. Irradiated and non-irradiated CAFs were examined for immunomodulation in experiments with peripheral blood mononuclear cells from random, healthy donors. Regulation of lymphocytes behavior was checked by lymphocyte proliferation assays, lymphocyte migration assays, and T-cell cytokine production. Additionally, CAF-secreted immunoregulatory factors were studied by multiplex protein arrays, ELISAs, and by LC-MS/MS proteomics. In all functional assays, we observed a powerful immunosuppressive effect exerted by CAF-conditioned medium on activated T-cells (p > 0.001), and this effect was sustained after a single radiation dose of 18 Gy. Relevant immunosuppressive molecules such as prostaglandin E2, interleukin-6, and -10, or transforming growth factor-β were found in CAF-conditioned medium, but their secretion was unchanged after irradiation. Finally, immunogenic cell death responses in CAFs were studied by exploring the release of high motility group box-1 and ATP. Both alarmins remained undetectable before and after irradiation. In conclusion, CAFs play a powerful immunosuppressive effect over activated T-cells, and this effect remains unchanged after HD-RT. Importantly, CAFs do not switch on immunogenic cell death responses after exposure to HD-RT.

  5. High dose rate interstitial brachytherapy in soft tissue sarcomas: technical aspect

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Mi Son; Kang, Seung Hee; Kim, Byoung Suck; Oh, Young Taek [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1999-03-01

    To discuss the technical aspect of interstitial brachytherapy including method of implant, insertion time of radioactive source, total radiation dose, and complication, we reviewed patients who had diagnoses of soft tissue sarcoma and were treated by conservative surgery, interstitial implant and external beam radiation therapy. Between May 1995 and Dec. 1997, the patients with primary or recurrent soft tissue sarcoma underwent surgical resection (wide margin excision) and received radiotherapy including interstitial brachytherapy. Catheters were placed with regular intervals of 1-1.5 cm immediately after tumor removal and covering the critical structures, such as neurovascular bundle or bone, with gelform, muscle, or tissue expander in the cases where the tumors were close to those structures. Brachytherapy consisted of source axis with 2-2.5 Gy/fraction, twice a day, starting on 6th day after the surgery. Within one month after the surgery, total dose of 50-55 Gy was delivered to the tumor bed with wide margin by the external beam radiotherapy. All patients completed planned interstitial brachytherapy without acute side effects directly related with catheter implantation such as infection or bleeding. With median follow up duration of 25 months (range 12-41 months), no local recurrences were observed. And there was no severe form of chromic complication (RTOG/EORTC grade 3 or 4). The high dose rate interstitial brachytherapy is easy and safe way to minimize the radiation dose delivered to the adjacent normal tissue and to decrease radiation induced chronic morbidity such as fibrosis by reducing the total dose of external radiotherapy in the management of soft tissue sarcoma with conservative surgery.

  6. Adaptive planning strategy for high dose rate prostate brachytherapy—a simulation study on needle positioning errors

    NARCIS (Netherlands)

    Borot, Maxence; Denis de Senneville, B; Maenhout, M; Hautvast, G; Binnekamp, D; Lagendijk, J J W; van Vulpen, M; Moerland, M A

    2016-01-01

    The development of magnetic resonance (MR) guided high dose rate (HDR) brachytherapy for prostate cancer has gained increasing interest for delivering a high tumor dose safely in a single fraction. To support needle placement in the limited workspace inside the closed-bore MRI, a single-needle MR-co

  7. Evaluation of risk of nephrotoxicity with high dose, extended-interval colistin administration

    Directory of Open Access Journals (Sweden)

    Arun Dewan

    2014-01-01

    Full Text Available Aim: The aim was to evaluate the risk of nephrotoxicity with high-dose, extended-interval regimen of colistin administration in critical ill patients. Materials and Methods: This prospective study was conducted on patients suffering from sepsis due to Gram-negative infection susceptible only to colistin. The dosing schedule for colistin was 9 million units stat followed by 4.5 million units at 12 hourly interval (adjusted as per body weight and renal functions. The serum creatinine and creatinine clearance were estimated at the start of therapy and daily during therapy. Results: Thirty-one patients suffering ventilator associated pneumonia (61.29%, blood stream infections (29.03% and urinary tract infections (9.67% due to Gram-negative multiple drug resistance organisms were assessed. Most commonly isolated organism were Acinetobacter baumannii (54.83%, Klebsiella pneumonia (16.12% and Pseudomonas (29.03%. Five patients (16.12% developed acute kidney injury within 4-5 days of start of therapy and returned to baseline after 6 days with no patient requiring renal replacement therapy or discontinuation of colistin. Conclusion: Our study showed that high-dose, extended-interval colistin can be given to critically ill patients without any significant risk of nephrotoxicity.

  8. Dietary intake of high-dose biotin inhibits spermatogenesis in young rats.

    Science.gov (United States)

    Sawamura, Hiromi; Ikeda, Chieko; Shimada, Ryoko; Yoshii, Yui; Watanabe, Toshiaki

    2015-02-01

    To characterize a new function of the water-soluble vitamin, biotin, in reproduction and early growth in mammals, the effects of high dietary doses of biotin on early spermatogenesis were biochemically and histologically investigated in male rats. Weaned rats were fed a CE-2 (control) diet containing 0.00004% biotin, or a control diet supplemented with 0.01%, 0.1%, or 1.0% biotin. Pair-fed rats were fed a control diet that was equal in calories to the amount ingested by the 1.0% biotin group, because food intake was decreased in the 1.0% biotin group. Food intake and body weight gain were lower in the 1.0% biotin group than in the control group. The kidney, brain and testis weights were significantly lower in the 1.0% biotin group than in the pair-fed group after 6 weeks of feeding. The accumulation of biotin in the liver and testis increased in a dose-dependent manner. In the 1.0% biotin group, the number of mature sperm was markedly lower, that of sperm with morphologically abnormal heads, mainly consisting of round heads, had increased. In addition, the development of seminiferous tubules was inhibited, and few spermatogonia and no spermatocytes were histologically observed. These results demonstrated that the long-term intake of high-dose biotin inhibited spermatogenesis in young male rats.

  9. High dose rate endorectal brachytherapy as a neoadjuvant treatment for patients with resectable rectal cancer.

    Science.gov (United States)

    Vuong, T; Devic, S; Podgorsak, E

    2007-11-01

    In the era of total mesorectal surgery, the issue of radiation toxicity is raised. A novel endocavitary brachytherapy technique was tested as a neoadjuvant treatment for patients with resectable rectal cancer. The objectives of the study were to evaluate the treatment-related toxicity and effects on local recurrence. A dose of 26 Gy was prescribed to the gross tumour volume and intramesorectal deposits seen on magnetic resonance imaging and given over four daily treatments, using the high dose rate delivery system followed by surgery 6-8 weeks later. The study included 93 T3, four T4 and three T2 tumours. Acute proctitis of grade 2 was observed in all patients, but one required transfusion. At a median follow-up time of 60 months, the 5-year actual local recurrence rate was 5%, disease-free survival was 65%, and overall survival was 70%. High dose rate endorectal brachytherapy seems to prevent local recurrence and has a favourable toxicity pattern compared with external beam radiotherapy.

  10. The impact of high and low dose ionising radiation on the central nervous system

    Directory of Open Access Journals (Sweden)

    Calina Betlazar

    2016-10-01

    Full Text Available Responses of the central nervous system (CNS to stressors and injuries, such as ionising radiation, are modulated by the concomitant responses of the brains innate immune effector cells, microglia. Exposure to high doses of ionising radiation in brain tissue leads to the expression and release of biochemical mediators of ‘neuroinflammation’, such as pro-inflammatory cytokines and reactive oxygen species (ROS, leading to tissue destruction. Contrastingly, low dose ionising radiation may reduce vulnerability to subsequent exposure of ionising radiation, largely through the stimulation of adaptive responses, such as antioxidant defences. These disparate responses may be reflective of non-linear differential microglial activation at low and high doses, manifesting as an anti-inflammatory or pro-inflammatory functional state. Biomarkers of pathology in the brain, such as the mitochondrial Translocator Protein 18 kDa (TSPO, have facilitated in vivo characterisation of microglial activation and ‘neuroinflammation’ in many pathological states of the CNS, though the exact function of TSPO in these responses remains elusive. Based on the known responsiveness of TSPO expression to a wide range of noxious stimuli, we discuss TSPO as a potential biomarker of radiation-induced effects.

  11. Low LET proton microbeam to understand high-LET RBE by shaping spatial dose distribution

    Science.gov (United States)

    Greubel, Christoph; Ilicic, Katarina; Rösch, Thomas; Reindl, Judith; Siebenwirth, Christian; Moser, Marcus; Girst, Stefanie; Walsh, Dietrich W. M.; Schmid, Thomas E.; Dollinger, Günther

    2017-08-01

    High LET radiation, like heavy ions, are known to have a higher biological effectiveness (RBE) compared to low LET radiation, like X- or γ -rays. Theories and models attribute these higher effectiveness mostly to their extremely inhomogeneous dose deposition, which is concentrated in only a few micron sized spots. At the ion microprobe SNAKE, low LET 20 MeV protons (LET in water of 2.6 keV/μm) can be applied to cells either randomly distributed or focused to submicron spots, approximating heavy ion dose deposition. Thus, the transition between low and high LET energy deposition is experimentally accessible and the effect of different spatial dose distributions can be analysed. Here, we report on the technical setup to cultivate and irradiate 104 cells with submicron spots of low LET protons to measure cell survival in unstained cells. In addition we have taken special care to characterise the beam spot of the 20 MeV proton microbeam with fluorescent nuclear track detectors.

  12. Treatment Of Pemphigus Vulgaris With Brief, High-Dose Intravenous Glucocorticoids

    Directory of Open Access Journals (Sweden)

    Farshchian Mahmood

    2004-01-01

    Full Text Available Background: Glucocorticoid therapy remains the mainstay of treatment in pemphigus vulgaris although controversy exists about the optimal regiman. This study was conducted to compare the efficacy of routine oral prednisolone with high dose intravenous glucocorticoids in treatment of pemphigus vulgaris. Methods: A total of 55 patients with pemphigus vulgaris was enrolled in the study. The diagnosis of pemphigus vulgaris was confirmed histologically. The patients were divided into two groups: Group A (26 Patients was treated with high-dose intravenous glucocorticoids and group B or control group (29 patients was treated with routine oral prednisolone. Both groups were followed for at least 20 months after initiation of treatment. Results: The results showed complete clinical cure (without relapse in 20 months follow up in 81% of cases in group A and in 69% of cases in group B (p<0.05. The mean + SD prednisolone daily dose during the 20 months follow up after initiation of treatment was 12+0.38 for A and 15.3 + 1.33 for control group (p<0.05.

  13. High doses of gamma radiation suppress allergic effect induced by food lectin

    Science.gov (United States)

    Vaz, Antônio F. M.; Souza, Marthyna P.; Vieira, Leucio D.; Aguiar, Jaciana S.; Silva, Teresinha G.; Medeiros, Paloma L.; Melo, Ana M. M. A.; Silva-Lucca, Rosemeire A.; Santana, Lucimeire A.; Oliva, Maria L. V.; Perez, Katia R.; Cuccovia, Iolanda M.; Coelho, Luana C. B. B.; Correia, Maria T. S.

    2013-04-01

    One of the most promising areas for the development of functional foods lies in the development of effective methods to reduce or eliminate food allergenicity, but few reports have summarized information concerning the progress made with food irradiation. In this study, we investigated the relationship between allergenicity and molecular structure of a food allergen after gamma irradiation and evaluate the profile of the allergic response to irradiated allergens. Cramoll, a lectin isolated from a bean and used as a food allergen, was irradiated and the possible structural changes were accompanied by spectrofluorimetry, circular dichroism and microcalorimetry. Subsequently, sensitized animals subjected to intragastric administration of non-irradiated and irradiated Cramoll were treated for 7 days. Then, body weight, leukocytes, cytokine profiles and histological parameters were also determined. Cramoll showed complete inhibition of intrinsic activity after high radiation doses. Changes in fluorescence and CD spectra with a simultaneous collapse of the tertiary structure followed by a pronounced decrease of native secondary structure were observed after irradiation. After oral challenge, sensitized mice demonstrate an association between Cramoll intake, body weight loss, eosinophilia, lymphocytic infiltrate in the gut and Eotaxin secretion. Irradiation significantly reduces, according to the dose, the effects observed by non-irradiated food allergens. We confirm that high-dose radiation may render protein food allergens innocuous by irreversibly compromising their molecular structure.

  14. [Stability of high-dose etoposide dilutions for use in hematopoietic stem cell transplantation conditioning regimens].

    Science.gov (United States)

    Bauters, T; Vandenbroucke, J; Commeyne, S

    2015-12-01

    High-dose etoposide is used in conditioning regimens for allogeneic stem cell transplantation. The limited stability of the drug induces barriers for its use for pharmacists, nurses and patients. When using a concentration of 10 mg/mL etoposide in physiologic saline, limitations can be overcome. This study provides stability data for etoposide in a high concentration that can be used in conditioning regimens. The solution was stable for 48h at 5°C, for 48h at 5°C followed by 8h at 25°C and for 24 h at 25°C.

  15. Intravenous high-dose immunotherapy: practical recommendations for use in the treatment of neurological disimmune diseases

    Directory of Open Access Journals (Sweden)

    N. A. Suponeva

    2015-01-01

    Full Text Available Current publication summarizes main indications and benefits of intravenous high-dose immunotherapy (IHI in the treatment of various autoimmune diseases of the peripheral nervous system. Available products of intravenous immunoglobulin (IVIG on the Russian market are reviewed. Tactics for choosing optimal medication for IHI based on its effectiveness and safety are analyzed. Dosage calculation and way of administration of IVIG are described, beeing of a high practical value in neurologist’s daily work.

  16. A comparison of batch and single wafer high dose arsenic ion implantation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Irwin, R.B.; Filo, A.J.; Kannan, V.C.; Feygenson, A.; Prematta, R.J.

    1989-04-01

    High dose, low energy (4x10/sup 15/ cm/sup -2/ at 15 keV) arsenic ion implantation into silicon was performed in batch and single wafer mode using medium and high current ion implanters. An investigation of implanted and annealed samples by Rutherford backscattering (RBS), transmission electron microscopy (TEM), thermal wave technique, and sheet resistance mapping showed little to no difference of arsenic profiles and residual damage between batch and single wafer implantation conditions when the sample temperature during implantation was kept below 120/sup 0/C. (orig.).

  17. A comparison of batch and single wafer high dose arsenic ion implantation techniques

    Science.gov (United States)

    Irwin, R. B.; Filo, A. J.; Kannan, V. C.; Feygenson, A.; Prematta, R. J.

    1989-04-01

    High dose, low energy (4×10 15 cm -2 at 15 keV) arsenic ion implantation into silicon was performed in batch and single wafer mode using medium and high current ion implanters. An investigation of implanted and annealed samples by Rutherford backscattering (RBS), transmission electron microscopy (TEM), thermal wave technique, and sheet resistance mapping showed little to no difference of arsenic profiles and residual damage between batch and single wafer implantation conditions when the sample temperature during implantation was kept below 120° C.

  18. High isoproterenol doses are required to activate beta3-adrenoceptor-mediated functions in dogs.

    Science.gov (United States)

    Pelat, Michel; Verwaerde, Patrick; Galitzky, Jean; Lafontan, Max; Berlan, Michel; Senard, Jean-Michel; Montastruc, Jean-Louis

    2003-01-01

    The "in vivo" conditions for beta3-adrenoceptors (beta-AR) activation by isoproterenol were investigated in dog. Experiments were carried out in anesthetized dogs using isoproterenol as a nonselective beta-AR agonist. Intravenous infusion of isoproterenol (0.4 nmol/kg/min) induced arterial hypotension and tachycardia with a slight decrease in cutaneous blood flow. At this dose, isoproterenol increased glucose, glycerol, and nonesterified fatty acid plasma levels. The changes in cardiovascular and endocrine-metabolic parameters, induced by the low dose of isoproterenol, were suppressed by pretreatment with nadolol (1 mg/kg, i.v.). After nadolol administration, however, a 10-fold higher dose (4 nmol/kg/min) of isoproterenol was able to induce a decrease in arterial blood pressure with a slight tachycardia and an increase in cutaneous blood flow. This high dose of isoproterenol increased nonesterified fatty acid and glycerol plasma levels but failed to change glucose plasma levels. All these effects were abolished by a pretreatment with nadolol (1 mg/kg, i.v.) plus SR59230A [a selective beta3-adrenoceptor antagonist; (3-(2-ethylphenoxy)-1(1S)-1,2,3,4-tetrahydronaphth-1-ylaminol-(2S)2-propanol oxalate); 1 mg/kg, i.v.]. Moreover, as observed with the high dose of isoproterenol under nadolol pretreatment, an infusion of SR58611A [a selective beta3-adrenoceptor agonist; ((N2S)-7-carbethoxymethoxy-1,2,3,4-tetrahydronaphth-2-yl-(2R)-2-hydroxy-2-chlorophenyl) ethanamine hydrochloride] induces a decrease in mean arterial blood pressure associated with an increase in heart rate, cutaneous blood flow, and nonesterified fatty acid and glycerol plasma levels. These results demonstrate that the in vivo activation of beta3-adrenoceptors requires higher doses of catecholamine than those necessary for beta1- and/or beta2-adrenoceptor stimulation. These results also argue for the lack of a beta3-AR involvement in the control of heart rate and glycogenolysis in dogs.

  19. The efficacy of high-dose penicillin for community-acquired pneumonia diagnosed by pneumococcal urine antigen test.

    Science.gov (United States)

    Oka, Hideaki; Ueda, Atsuhisa; Watanuki, Yuji; Tsukiji, Jun; Kuroda, Hideyo; Akashi, Syunsuke; Hirai, Yoshihiro; Fuyuki, Toshiharu; Kaneko, Takeshi; Ishigatsubo, Yoshiaki

    2009-04-01

    We analyzed the efficacy of both the Streptococcus pneumoniae urine antigen test as a quick diagnostic tool and the administration of high-dose penicillin in response to a positive S. pneumoniae urine antigen test. We conducted a retrospective analysis of 48 cases of pneumococcal pneumonia, in which the patients were treated with high-dose penicillin. All the cases were diagnosed by a positive urine antigen test. Treatment with high-dose penicillin was effective in 43 of the 48 patients. This treatment was also effective in 12 of 16 culture-confirmed cases with low susceptibility to penicillin. Eleven patients who were positive for the S. pneumoniae urine antigen test but culture-negative showed clinical improvement with high-dose penicillin. Pneumonia caused by S. pneumoniae appeared to be treated safely and effectively with high-dose penicillin based on positive results of the urine antigen test, as penicillin resistance was unlikely to be a problem.

  20. RADIATION DOSE MEASUREMENTS FOR HIGH-INTENSITY LASER INTERACTIONS WITH SOLID TARGETS AT SLAC.

    Science.gov (United States)

    Liang, T; Bauer, J; Cimeno, M; Ferrari, A; Galtier, E; Granados, E; Lee, H J; Liu, J; Nagler, B; Prinz, A; Rokni, S; Tran, H; Woods, M

    2016-12-01

    A systematic study of photon and neutron radiation doses generated in high-intensity laser-solid interactions is underway at SLAC National Accelerator Laboratory. These laser-solid experiments are being performed using a 25 TW (up to 1 J in 40 fs) femtosecond pulsed Ti:sapphire laser at the Linac Coherent Light Source's (LCLS) Matter in Extreme Conditions (MEC) facility. Radiation measurements were performed with passive and active detectors deployed at various locations inside and outside the target chamber. Results from radiation dose measurements for laser-solid experiments at SLAC MEC in 2014 with peak intensity between 10(18) and 7.1 × 10(19) W cm(-2) are presented.

  1. Analysis of dose-LET distribution in the human body irradiated by high energy hadrons.

    Science.gov (United States)

    Sato, T; Tsuda, S; Sakamoto, Y; Yamaguchi, Y; Niita, K

    2003-01-01

    For the purposes of radiological protection, it is important to analyse profiles of the particle field inside a human body irradiated by high energy hadrons, since they can produce a variety of secondary particles which play an important role in the energy deposition process, and characterise their radiation qualities. Therefore Monte Carlo calculations were performed to evaluate dose distributions in terms of the linear energy transfer of ionising particles (dose-LET distribution) using a newly developed particle transport code (Particle and Heavy Ion Transport code System, PHITS) for incidences of neutrons, protons and pions with energies from 100 MeV to 200 GeV. Based on these calculations, it was found that more than 80% and 90% of the total deposition energies are attributed to ionisation by particles with LET below 10 keV microm(-1) for the irradiations of neutrons and the charged particles, respectively.

  2. Radiation Dose Measurement for High-Intensity Laser Interactions with Solid Targets at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Taiee [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-09-25

    A systematic study of photon and neutron radiation doses generated in high-intensity laser-solid interactions is underway at SLAC National Accelerator Laboratory. We found that these laser-solid experiments are being performed using a 25 TW (up to 1 J in 40 fs) femtosecond pulsed Ti:sapphire laser at the Linac Coherent Light Source’s (LCLS) Matter in Extreme Conditions (MEC) facility. Additionally, radiation measurements were performed with passive and active detectors deployed at various locations inside and outside the target chamber. Results from radiation dose measurements for laser-solid experiments at SLAC MEC in 2014 with peak intensity between 1018 to 7.1x1019 W/cm2 are presented.

  3. Regeneration of parotid acinar cells after high radiation doses. A morphological study in rat

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, H. [Depts. of Oto-Rhino-Laryngology, Histology and Cell Biology, Umeaa Univ. (Sweden); Franzen, L. [Dept. of Oncology, Umeaa Univ. (Sweden); Henriksson, R. [Dept. of Oncology, Umeaa Univ. (Sweden)

    1995-12-31

    The acute and late effects of fractionated irradiation on rat parotid gland acinar cells were studied by light and electron microscopy. At 10 days after the last irradiation session (6 Gy or 9 Gy daily during five consecutive days) no effects were seen. At 180 days, minor loss of acini was detectable after a total dose of 30 Gy. After 45 Gy a massive acinar loss was seen at that time; the number of acini had diminished and minor duct-like structures and scattered amounts of fibrous stroma dominated the slides. The remaining acini were disorganized and usually larger compared with the control side and to non-irradiated animals. The acinar cells appeared larger than in the controls. The custs were better preserved but the intercalated ducts often seemed to be larger than normal. We suggest that this phenomenon indicates a remaining capacity of the parotid gland to regenerate acinar cells even after high radiation doses. (orig.).

  4. Characterization of High Dose Mn, Fe, and Ni implantation into p-GaN

    CERN Document Server

    Pearton, S J; Thaler, G; Abernathy, C R; Theodoropoulou, N; Hebard, A F; Chu, S N G; Wilson, R G; Zavada, J M; Polyakov, A Y; Osinsky, A V; Norris, P E; Chow, P P; Wowchack, A M; Hove, J M V; Park, Y D

    2002-01-01

    The magnetization of p-GaN or p-AlGaN/GaN superlattices was measured after implantation with high doses (3-5x10 sup 1 sup 6 cm sup - sup 2) of Mn, Fe, or Ni and subsequent annealing at 700-1000 deg. C. The samples showed ferromagnetic contributions below temperatures ranging from 190-250 K for Mn to 45-185 K for Ni and 80-250 K for Fe. The use of superlattices to enhance the hole concentration did not produce any change in ferromagnetic ordering temperature. No secondary phase formation was observed by x-ray diffraction, transmission electron microscopy, or selected area diffraction pattern analysis for the doses we employed.

  5. High-dose ifosfamide and mesna in advanced breast cancer. A phase II study.

    Science.gov (United States)

    Sanchiz, F; Milla, A

    1990-01-01

    Thirty-two patients with metastatic breast cancer had previously been treated with chemotherapy (including anthracyclines). They were included in a trial to receive 6 g/m3 ifosfamide, mixed with 6 g/m2 mesna in 1000 ml saline infusion, infused over 4 h. Therapy was repeated every 21 days; the dose was reduced by 50%. Twenty-eight patients could be evaluated. An average of 4.2 cycles (range 2-8) was applied. One patient (4%) showed complete remission. Ten patients (36%) had a partial response. Ten patients (36%) experienced SD and the remaining patients (25%) PD. We conclude that high-dose ifosfamide shows activity in this group of pretreated patients and merits further investigation.

  6. High precision measurements of arsenic and phosphorous implantation dose in silicon by secondary ion mass spectrometry

    CERN Document Server

    Chi, P H; McKinley, J M; Stevie, F A; Granger, C N

    2002-01-01

    The metrology section of the 1999 International Technology Roadmap for Semiconductors specifies in-line dopant profile concentration precision requirements ranging from a value of 5% in 1999 to a value of 2% in 2008. These values are to be accomplished with ''low systematic error.'' Secondary ion mass spectrometry (SIMS) has demonstrated the capability to meet these requirements for B, As, and P. However, the detailed analytical protocols required to achieve these goals have not been completely specified. This article reports the parameters that must be controlled to make highly repeatable dose measurements of As and P implants in Si with magnetic sector SIMS instruments. Instrument conditions that were investigated include analytical species, matrix ion species, energy bandpass, and sample holder design. With optimized settings, we demonstrate the ability to distinguish As or P implant doses differing by 5%.

  7. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

    Directory of Open Access Journals (Sweden)

    Luciana Tourinho Campos

    Full Text Available The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®; it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86, which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21, which is also from BEBIG.The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair

  8. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy

    Science.gov (United States)

    Campos, Luciana Tourinho; de Almeida, Carlos Eduardo Veloso

    2015-01-01

    Introduction The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®); it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86), which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21), which is also from BEBIG. Objective and Methods The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the

  9. Immunomodulatory Changes Induced By High Doses Of Dextromethorphan In Male Rats

    Directory of Open Access Journals (Sweden)

    Hanan Mostafa Rabei

    2013-04-01

    Full Text Available Background:Dextromethorphan (DXM is a synthetic opioid analogue, similar to codeine that has antitussive effect but no opiate-like analgesic activity. It is widely used as an over-the-counter cough suppressant available in various cough and cold preparations; it is one of the often overlooked types of substance abuse by adolescents and young adults in the United States and around the world. So, the present study aims to investigate the side effects of the DXM abuse (sub-chronic and lethal doses on the immune functions in rats. Material and Methods:The rats were divided into three equal groups, the first one served as control, and the second and third were treated. Treated groups received oral doses of DXM which increasing per 10 days (double dose for a month. ResultsWe examined the sub-chronic and lethal effects of DXM administration on the cellular immune responses in rats. T cell stimulator, Phytohemagglutinin showed a significant suppress on lymphocytes of peripheral blood proliferation and a highly significant decrease on phagocytic and killing of S. aureus by PMN and macrophage cells. Moreover, it induced a significant decrease in serum IL-6, and IFN-γ levels, but, it exhibited a highly significant increase in serum IL-10 level throughout the period of experiment. In addition, it induced also a significant decrease in the production of cortisol during the experimental time except the last period of treatment in the 3rd group, where, serum cortisol level gradually return to normal level. Conclusion:These results suggest that sub-chronic and lethal doses of DXM administration in rats disturbed cellular immune responses, exhibited potent anti-inflammatory actions, suppressed of leukocytes dependent production of cytokines such as IL-6 and IFN-γ. Moreover, it has some effects on serum cortisol concentration presumably via blockade of NMDA receptors

  10. Quality control of high-dose-rate brachytherapy: treatment delivery analysis using statistical process control.

    Science.gov (United States)

    Able, Charles M; Bright, Megan; Frizzell, Bart

    2013-03-01

    Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

    Energy Technology Data Exchange (ETDEWEB)

    Able, Charles M., E-mail: cable@wfubmc.edu [Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, North Carolina (United States); Bright, Megan; Frizzell, Bart [Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, North Carolina (United States)

    2013-03-01

    Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

  12. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate (192) Ir brachytherapy.

    Science.gov (United States)

    Ma, Yunzhi; Vijande, Javier; Ballester, Facundo; Carlsson Tedgren, Åsa; Granero, Domingo; Haworth, Annette; Mourtada, Firas; Fonseca, Gabriel Paiva; Zourari, Kyveli; Papagiannis, Panagiotis; Rivard, Mark J; Siebert, Frank André; Sloboda, Ron S; Smith, Ryan; Chamberland, Marc J P; Thomson, Rowan M; Verhaegen, Frank; Beaulieu, Luc

    2017-07-19

    A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform model-based dose calculation algorithms (MBDCA) dose calculations and comparisons. Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR) (192) Ir shielded applicator has been designed and benchmarked. A generic HDR (192) Ir shielded applicator was designed based on three commercially available gynecological applicators as well as a virtual cubic water phantom that can be imported into any DICOM-RT compatible treatment planning system (TPS). The absorbed dose distribution around the applicator with the TG-186 (192) Ir source located at one dwell position at its center was computed using two commercial TPSs incorporating MBDCAs (Oncentra(®) Brachy with Advanced Collapsed-cone Engine, ACE(™) , and BrachyVision ACUROS(™) ) and state-of-the-art Monte Carlo (MC) codes, including ALGEBRA, BrachyDose, egs_brachy, Geant4, MCNP6, and Penelope2008. TPS-based volumetric dose distributions for the previously reported "source centered in water" and "source displaced" test cases, and the new "source centered in applicator" test case, were analyzed here using the MCNP6 dose distribution as a reference. Volumetric dose comparisons of TPS results against results for the other MC codes were also performed. Distributions of local and global dose difference ratios are reported. The local dose differences among MC codes are comparable to the statistical uncertainties of the reference datasets for the "source centered in water" and "source

  13. Oral lorazepam prevents seizure during high-dose busulfan in children undergoing hematopoietic stem cell transplantation: a prospective study.

    Science.gov (United States)

    Hamidieh, Amir Ali; Hamedani, Ravak; Hadjibabaie, Molouk; Amini, Mohsen; Sadrai, Sima; Ghavamzadeh, Ardeshir

    2010-10-01

    High-dose Busulfan in combination chemotherapy has been used commonly for hematopoietic stem cell transplantation. It crosses the blood-brain barrier and could cause seizure. Benzodiazepines have been used as anticonvulsant prophylaxis. This is a prospective study using oral lorazepam together with busulfan-based conditioning regimen in 30 children undergoing hematopoietic stem cell transplantation. The dose of lorazepam used ranged from 0.017 to 0.039 mg/kg (median = 0.026 mg/kg) per dose. None of the patients developed seizure while receiving oral lorazepam or within 72 hours of the last dose of Busulfan. Oral lorazepam was tolerated by the patients, but all patients needed dose reduction due to some adverse effects. In the authors' experience, oral lorazepam is a useful anticonvulsant prophylaxis for children receiving high-dose busulfan.

  14. Dosimetric feasibility of ablative dose escalated focal monotherapy with MRI-guided high-dose-rate (HDR) brachytherapy for prostate cancer.

    Science.gov (United States)

    Hosni, Ali; Carlone, Marco; Rink, Alexandra; Ménard, Cynthia; Chung, Peter; Berlin, Alejandro

    2017-01-01

    To determine the dosimetric feasibility of dose-escalated MRI-guided high-dose-rate brachytherapy (HDR-BT) focal monotherapy for prostate cancer (PCa). In all patients, GTV was defined with mpMRI, and deformably registered onto post-catheter insertion planning MRI. PTV included the GTV plus 9mm craniocaudal and 5mm in every other direction. In discovery-cohort, plans were obtained for each PTV independently aiming to deliver ⩾16.5Gy/fraction (two fraction schedule) while respecting predefined organs-at-risk (OAR) constraints or halted when achieved equivalent single-dose plan (24Gy). Dosimetric results of original and focal HDR-BT plans were evaluated to develop a planning protocol for the validation-cohort. In discovery-cohort (20-patients, 32-GTVs): PTV D95% ⩾16.5Gy could not be reached in a single plan (3%) and was accomplished (range 16.5-23.8Gy) in 15 GTVs (47%). Single-dose schedule was feasible in 16 (50%) plans. In the validation-cohort (10-patients, 10-GTVs, two separate implants each): plans met acceptable and ideal criteria in 100% and 43-100% respectively. Migration to single-dose treatment schedule was feasible in 7 implants (35%), without relaxing OAR's constraints or increasing the dose (D100% and D35%) to mpMRI-normal prostate (p>0.05). Focal ablative dose-escalated radiation is feasible with the proposed protocol. Prospective studies are warranted to determine the clinical outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Safety and immunologic effects of high- vs low-dose cholecalciferol in multiple sclerosis

    Science.gov (United States)

    Sotirchos, Elias S.; Bhargava, Pavan; Eckstein, Christopher; Van Haren, Keith; Baynes, Moira; Ntranos, Achilles; Gocke, Anne; Steinman, Lawrence; Mowry, Ellen M.

    2016-01-01

    Objective: To study the safety profile and characterize the immunologic effects of high- vs low-dose cholecalciferol supplementation in patients with multiple sclerosis (MS). Methods: In this double-blind, single-center randomized pilot study, 40 patients with relapsing-remitting MS were randomized to receive 10,400 IU or 800 IU cholecalciferol daily for 6 months. Assessments were performed at baseline and 3 and 6 months. Results: Mean increase of 25-hydroxyvitamin D levels from baseline to final visit was larger in the high-dose group (34.9 ng/mL; 95% confidence interval [CI] 25.0–44.7 ng/mL) than in the low-dose group (6.9 ng/mL; 95% CI 1.0–13.7 ng/mL). Adverse events were minor and did not differ between the 2 groups. Two relapses occurred, one in each treatment arm. In the high-dose group, we found a reduction in the proportion of interleukin-17+CD4+ T cells (p = 0.016), CD161+CD4+ T cells (p = 0.03), and effector memory CD4+ T cells (p = 0.021) with a concomitant increase in the proportion of central memory CD4+ T cells (p = 0.018) and naive CD4+ T cells (p = 0.04). These effects were not observed in the low-dose group. Conclusions: Cholecalciferol supplementation with 10,400 IU daily is safe and tolerable in patients with MS and exhibits in vivo pleiotropic immunomodulatory effects in MS, which include reduction of interleukin-17 production by CD4+ T cells and decreased proportion of effector memory CD4+ T cells with concomitant increase in central memory CD4+ T cells and naive CD4+ T cells. Classification of evidence: This study provides Class I evidence that cholecalciferol supplementation with 10,400 IU daily is safe and well-tolerated in patients with MS and exhibits in vivo pleiotropic immunomodulatory effects. PMID:26718578

  16. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moussazadeh, Nelson [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katsoulakis, Evangelia [Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, New York (United States); Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bilsky, Mark H. [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Laufer, Ilya, E-mail: lauferi@mskcc.org [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States)

    2015-10-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  17. Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Gordic, Sonja; Husarik, Daniela B.; Alkadhi, Hatem [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Desbiolles, Lotus; Leschka, Sebastian [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Kantonsspital, Divison of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Sedlmair, Martin; Schmidt, Bernhard [Siemens Healthcare, Computed Tomography Division, Forchheim (Germany); Manka, Robert [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); University Hospital Zurich, University of Zurich, Clinic of Cardiology, Zurich (Switzerland); University and ETH Zurich, Institute for Biomedical Engineering, Zurich (Switzerland); Plass, Andre; Maisano, Francesco [University Hospital Zurich, University of Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland); Wildermuth, Simon [Kantonsspital, Divison of Radiology and Nuclear Medicine, St. Gallen (Switzerland)

    2016-02-15

    To evaluate the potential of advanced modeled iterative reconstruction (ADMIRE) for optimizing radiation dose of high-pitch coronary CT angiography (CCTA). High-pitch 192-slice dual-source CCTA was performed in 25 patients (group 1) according to standard settings (ref. 100 kVp, ref. 270 mAs/rot). Images were reconstructed with filtered back projection (FBP) and ADMIRE (strength levels 1-5). In another 25 patients (group 2), high-pitch CCTA protocol parameters were adapted according to results from group 1 (ref. 160 mAs/rot), and images were reconstructed with ADMIRE level 4. In ten patients of group 1, vessel sharpness using full width at half maximum (FWHM) analysis was determined. Image quality was assessed by two independent, blinded readers. Interobserver agreements for attenuation and noise were excellent (r = 0.88/0.85, p < 0.01). In group 1, ADMIRE level 4 images were most often selected (84 %, 21/25) as preferred data set; at this level noise reduction was 40 % compared to FBP. Vessel borders showed increasing sharpness (FWHM) at increasing ADMIRE levels (p < 0.05). Image quality in group 2 was similar to that of group 1 at ADMIRE levels 2-3. Radiation dose in group 2 (0.3 ± 0.1 mSv) was significantly lower than in group 1 (0.5 ± 0.3 mSv; p < 0.05). In a selected population, ADMIRE can be used for optimizing high-pitch CCTA to an effective dose of 0.3 mSv. (orig.)

  18. Long-Term Outcomes After High-Dose Postprostatectomy Salvage Radiation Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Goenka, Anuj; Magsanoc, Juan Martin; Pei Xin; Schechter, Michael; Kollmeier, Marisa; Cox, Brett [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Scardino, Peter T.; Eastham, James A. [Urology Service, Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Zelefsky, Michael J., E-mail: zelefskm@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-09-01

    Purpose: To review the impact of high-dose radiotherapy (RT) in the postprostatectomy salvage setting on long-term biochemical control and distant metastases-free survival, and to identify clinical and pathologic predictors of outcomes. Methods and Materials: During 1988-2007, 285 consecutive patients were treated with salvage RT (SRT) after radical prostatectomy. All patients were treated with either three-dimensional conformal RT or intensity-modulated RT. Two hundred seventy patients (95%) were treated to a dose {>=}66 Gy, of whom 205 (72%) received doses {>=}70 Gy. Eighty-seven patients (31%) received androgen-deprivation therapy as a component of their salvage treatment. All clinical and pathologic records were reviewed to identify treatment risk factors and response. Results: The median follow-up time after SRT was 60 months. Seven-year actuarial prostate-specific antigen (PSA) relapse-free survival and distant metastases-free survival were 37% and 77%, respectively. Independent predictors of biochemical recurrence were vascular invasion (p < 0.01), negative surgical margins (p < 0.01), presalvage PSA level >0.4 ng/mL (p < 0.01), androgen-deprivation therapy (p = 0.03), Gleason score {>=}7 (p = 0.02), and seminal vesicle involvement (p = 0.05). Salvage RT dose {>=}70 Gy was not associated with improvement in biochemical control. A doubling time <3 months was the only independent predictor of metastatic disease (p < 0.01). There was a trend suggesting benefit of SRT dose {>=}70 Gy in preventing clinical local failure in patients with radiographically visible local disease at time of SRT (7 years: 90% vs. 79.1%, p = 0.07). Conclusion: Salvage RT provides effective long-term biochemical control and freedom from metastasis in selected patients presenting with detectable PSA after prostatectomy. Androgen-deprivation therapy was associated with improvement in biochemical progression-free survival. Clinical local failures were rare but occurred most commonly in

  19. A systematic review of pediatric clinical trials of high dose vitamin D

    Directory of Open Access Journals (Sweden)

    Nassr Nama

    2016-02-01

    Full Text Available Background. Due to inadequate UV exposure, intake of small quantities of vitamin D is recommended to prevent musculoskeletal disease. Both basic science and observational literature strongly suggest that higher doses may benefit specific populations and have non-musculoskeletal roles. Evaluating the evidence surrounding high dose supplementation can be challenging given a relatively large and growing body of clinical trial evidence spanning time, geography, populations and dosing regimens. Study objectives were to identify and summarize the clinical trial literature, recognize areas with high quality evidence, and develop a resource database that makes the literature more immediately accessible to end users. Methods. Medline (1946 to January 2015, Embase (1974 to January 2015, and Cochrane databases (January 2015, were searched for trials. All pediatric (0–18 years trials administering doses higher than 400 IU (<1 year or 600 IU (≥1 year were included. Data was extracted independently by two of the authors. An online searchable database of trials was developed containing relevant extracted information (http://www.cheori.org/en/pedvitaminddatabaseOverview. Sensitivity and utility were assessed by comparing the trials in the database with those from systematic reviews of vitamin D supplementation including children. Results. A total of 2,579 candidate papers were identified, yielding 169 trials having one or more arms meeting eligibility criteria. The publication rate has increased significantly from 1 per year (1970–1979 to 14 per year (2010–2015. Although 84% of the total trials focused on healthy children or known high risk populations (e.g., renal, prematurity, this proportion has declined in recent years due to the rise in trials evaluating populations and outcomes not directly related to the musculoskeletal actions of vitamin D (27% in 2010s. Beyond healthy children, the only pediatric populations with more than 50 participants from

  20. Design and implementation of a film dosimetry audit tool for comparison of planned and delivered dose distributions in high dose rate (HDR) brachytherapy

    Science.gov (United States)

    Palmer, Antony L.; Lee, Chris; Ratcliffe, Ailsa J.; Bradley, David; Nisbet, Andrew

    2013-10-01

    A novel phantom is presented for ‘full system’ dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.

  1. High-Dose Menaquinone-7 Supplementation Reduces Cardiovascular Calcification in a Murine Model of Extraosseous Calcification

    Directory of Open Access Journals (Sweden)

    Daniel Scheiber

    2015-08-01

    Full Text Available Cardiovascular calcification is prevalent in the aging population and in patients with chronic kidney disease (CKD and diabetes mellitus, giving rise to substantial morbidity and mortality. Vitamin K-dependent matrix Gla-protein (MGP is an important inhibitor of calcification. The aim of this study was to evaluate the impact of high-dose menaquinone-7 (MK-7 supplementation (100 µg/g diet on the development of extraosseous calcification in a murine model. Calcification was induced by 5/6 nephrectomy combined with high phosphate diet in rats. Sham operated animals served as controls. Animals received high or low MK-7 diets for 12 weeks. We assessed vital parameters, serum chemistry, creatinine clearance, and cardiac function. CKD provoked increased aortic (1.3 fold; p < 0.05 and myocardial (2.4 fold; p < 0.05 calcification in line with increased alkaline phosphatase levels (2.2 fold; p < 0.01. MK-7 supplementation inhibited cardiovascular calcification and decreased aortic alkaline phosphatase tissue concentrations. Furthermore, MK-7 supplementation increased aortic MGP messenger ribonucleic acid (mRNA expression (10-fold; p < 0.05. CKD-induced arterial hypertension with secondary myocardial hypertrophy and increased elastic fiber breaking points in the arterial tunica media did not change with MK-7 supplementation. Our results show that high-dose MK-7 supplementation inhibits the development of cardiovascular calcification. The protective effect of MK-7 may be related to the inhibition of secondary mineralization of damaged vascular structures.

  2. Dose estimation and shielding calculation for X-ray hazard at high intensity laser facilities

    Science.gov (United States)

    Qiu, Rui; Zhang, Hui; Yang, Bo; James, C. Liu; Sayed, H. Rokni; Michael, B. Woods; Li, Jun-Li

    2014-12-01

    An ionizing radiation hazard produced from the interaction between high intensity lasers and solid targets has been observed. Laser-plasma interactions create “hot” electrons, which generate bremsstrahlung X-rays when they interact with ions in the target. However, up to now only limited studies have been conducted on this laser-induced radiological protection issue. In this paper, the physical process and characteristics of the interaction between high intensity lasers and solid targets are analyzed. The parameters of the radiation sources are discussed, including the energy conversion efficiency from laser to hot electrons, hot electron energy spectrum and electron temperature, and the bremsstrahlung X-ray energy spectrum produced by hot electrons. Based on this information, the X-ray dose generated with high-Z targets for laser intensities between 1014 and 1020 W/cm2 is estimated. The shielding effects of common shielding items such as the glass view port, aluminum chamber wall and concrete wall are also studied using the FLUKA Monte Carlo code. This study provides a reference for the dose estimation and the shielding design of high intensity laser facilities.

  3. Taurine-EVA copolymer-paraffin rods dosimeters for EPR high-dose radiation dosimetry

    Directory of Open Access Journals (Sweden)

    Maghraby Ahmed M.

    2014-03-01

    Full Text Available Taurine/EPR rods (3 × 10 mm have been prepared by a simple technique in the laboratory where taurine powder was mixed with a molten mixture of paraffin wax and an ethylene vinyl acetate (EVA copolymer. The binding mixture EVA/Paraffin does not present interference or noise in the EPR signal before or after irradiation. The rods show good mechanical properties for safe and multi-use handling. An EPR investigation of radiation induced radicals in taurine rods revealed that there are two types of radicals produced after exposure to gamma radiation (60Co. EPR spectra were recorded and analyzed - also the microwave power saturation and modulation amplitude were studied and optimized. Response of taurine to different radiation doses (1.5-100 kGy was studied and found to follow a linear relationship up to 100 kGy. Radiation induced radicals in taurine persists and showed a noticeable stability over 94 days following irradiation. Uncertainities associated with the evaluation of radiation doses using taurine dosimeters were discussed and tabulated. It was found that taurine possesses good dosimetric properties using EPR spectroscopy in high doses in addition to its simple spectrum.

  4. Survival of tumor cells after proton irradiation with ultra-high dose rates

    Directory of Open Access Journals (Sweden)

    Belka Claus

    2011-10-01

    Full Text Available Abstract Background Laser acceleration of protons and heavy ions may in the future be used in radiation therapy. Laser-driven particle beams are pulsed and ultra high dose rates of >109 Gy s-1may be achieved. Here we compare the radiobiological effects of pulsed and continuous proton beams. Methods The ion microbeam SNAKE at the Munich tandem accelerator was used to directly compare a pulsed and a continuous 20 MeV proton beam, which delivered a dose of 3 Gy to a HeLa cell monolayer within Results At 10 h after pulsed irradiation, the fraction of G2 cells was significantly lower than after irradiation with the continuous beam, while all other endpoints including colony formation were not significantly different. We determined the relative biological effectiveness (RBE for pulsed and continuous proton beams relative to x-irradiation as 0.91 ± 0.26 and 0.86 ± 0.33 (mean and SD, respectively. Conclusions At the dose rates investigated here, which are expected to correspond to those in radiation therapy using laser-driven particles, the RBE of the pulsed and the (conventional continuous irradiation mode do not differ significantly.

  5. High-dose-rate interstitial brachytherapy for the treatment of penile carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Petera, J.; Odrazka, K.; Zouhar, M.; Bedrosova, J.; Dolezel, M. [Dept. of Oncology and Radiotherapy, Charles Univ. Medical School and Teaching Hospital, Hradec Kralove (Czech Republic)

    2004-02-01

    Background: interstitial low-dose-rate (LDR) brachytherapy allows conservative treatment of T1-T2 penile carcinoma. High-dose-rate (HDR) is often considered to be dangerous for interstitial implants because of a higher risk of complications, but numerous reports suggest that results may be comparable to LDR. Nevertheless, there are no data in the literature available regarding HDR interstitial brachytherapy for carcinoma of the penis. Case report: a 64-year-old man with T1 NO MO epidermoid carcinoma of the glans is reported. Interstitial HDR brachytherapy was performed using the stainless hollow needle technique and a breast template for fixation and good geometry. The dose delivered was 18 x 3 Gy twice daily. Results: after 232 days from brachytherapy, the patient was without any evidence of the tumor, experienced no serious radiation-induced complications, and had a fully functional organ. Conclusion: HDR interstitial brachytherapy is feasible in selected case of penis carcinoma, when careful planning and small single fractions are used. (orig.)

  6. High-Dose Amoxicillin with Clavulanate for the Treatment of Acute Otitis Media in Children

    Directory of Open Access Journals (Sweden)

    Chia-Huei Chu

    2014-01-01

    Full Text Available Objective. This study uses the acute otitis media clinical practice guideline proposed in 2004 as a reference to evaluate whether antibiotics doses that are in line with the recommendations lead to better prognosis. The study also attempts to clarify possible factors that influence the outcome. Study Design. Retrospective cohort study. Subjects and Methods. A total of 400 children with acute otitis media were enrolled. The dosage of amoxicillin was considered to be appropriate when in accord with clinical practice guidelines, that is, 80–90 mg/kg/day. The outcome was defined according to the description of tympanic membrane on medical records. Multivariate logistic regression was used to analyze the relationship between antibiotic dosage and prognosis after adjusting for baseline factors. Results. The majority of prescriptions were under dosage (89.1% but it was not noticeably associated with outcome (P= 0.41. The correlation between under dosage and poor prognosis was significant in children below 20 kg with bilateral acute otitis media (odds ratio 1.63; 95% CI 1.02–2.59, P=0.04. Conclusion. Treating acute otitis media in children, high-dose amoxicillin with clavulanate as recommended in the clinical practice guideline was superior to conventional doses only in children under 20 kg with bilateral diseases.

  7. Engraftment of DLA-nonidentical unrelated canine marrow after high-dose fractionated total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Deeg, H.J. (Fred Hutchinson Cancer Research Center, Seattle, WA); Storb, R.; Shulman, H.M.; Weiden, P.L.; Graham, T.C.; Thomas, E.D.

    1982-04-01

    Marrow transplants were carried out between unrelated DLA-nonidentical dogs. Recipients were conditioned for transplantation by total body irradiation (TBI) given either as a single dose of 9 Gy (900 rad) or fractionated in three increments of 6 Gy (600 rad) each at intervals of 48 hr. All recipients received marrow, less than or equal to to 4 X 10/sup 8/ cells/kg, and no buffy coat cells. No immunosuppression was given after grafting. All 10 dogs given single-dose total body irradiation failed to show engraftment and died with marrow aplasia and infectious complications (median survival 12 days). In contrast, all 10 dogs given fractionated TBI had sustained engraftment and died with graft-versus-host disease (GVHD) and infectious complications (median survival 12.5 days). None of the dogs died from radiation-induced gastroenteritis.In conclusion, resistance to DLA-nonidentical unrelated marrow grafts can be abrogated by high-dose TBI. This technique may allow hemopoietic engraftment even after in vitro manipulation of the marrow such as lymphocyte depletion by cell separation or treatment with anti-T cell antisera.

  8. Engraftment of DLA-nonidentical unrelated canine marrow after high-dose fractionated total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Deeg, H.J.; Storb, R.; Shulman, H.M.; Weiden, P.L.; Graham, T.C.; Thomas, E.D.

    1982-04-01

    Marrow transplants were carried out between unrelated DLA-nonidentical dogs. Recipients were conditioned for transplantation by total body irradiation (TBI) given eigher as a single dose of 9 Gy (900 rad) or fractionated in three increments of 6 Gy (600 rad) each at intervals of 48 hr. All recipients received marrow, less than or equal to 4 x 10(8) cells/kg, and no buffy coat cells. No immunosuppression was given after grafting. All 10 dogs given single dose total body irradiation failed to show engraftment and died with marrow aplasia and infectious complications (median survival 12 days). In contrast, all 10 dogs given fractionated TBI had sustained engraftment and died with graft-versus-host disease (GVHD) and infectious complications (median survival 12.5 days). None of the dogs died from radiation-induced gastroenteritis. In conclusion, resistance to DLA-nonidentical unrelated marrow grafts can be abrogated by high-dose TBI. This technique may allow hemopoietic engraftment even after i vitro manipulation of the marrow such as lymphocyte depletion by cell separation or treatment with anti-T cell antisera.

  9. Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source

    Science.gov (United States)

    Granero, Domingo; Perez-Calatayud, Jose; Ballester, Facundo

    2012-01-01

    Purpose Recently, a new HDR 60Co brachytherapy source, Flexisource Co-60, has been developed (Nucletron B.V. Veenendaal, The Netherlands). This study aims to obtain dosimetric data for this source for its use in clinical practice as required by AAPM and ESTRO. Material and methods Two Monte Carlo radiation transport codes were used: Penelope2008 and GEANT4. The source was centrally-positioned in a 100 cm radius water phantom. Absorbed dose and collisional kerma were obtained using 0.01 cm (close) and 0.1 cm (far) sized voxels to provide high-resolution dosimetry near (far from) the source. Dose rate distributions obtained with the two Monte Carlo codes were compared. Results and Discussion Simulations performed with those two radiation transport codes showed an agreement typically within 0.2% for r > 0.8 cm and up to 2% closer to the source. Detailed results of dose distributions are being made available. Conclusions Dosimetric data are provided for the new Flexisource Co-60 source. These data are meant to be used in treatment planning systems in clinical practice. PMID:23346138

  10. High dose chemotherapy with stem cell support in thetreatment of testicular cancer

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    Testicular germ cell cancer (TGCC) is rare form ofmalignant disease that occurs mostly in young manbetween age 15 and 40. The worldwide incidence ofTGCC is 1.5 per 100000 man with the highest rates inNorth Europe. After discovery of cisplatin cure ratesof TGCC are very favorable between 90%-95% andunlike most solid tumors, cure rate for metastatic TGCCis around 80%. Metastatic TGCC is usually treatedwith 3-4 cycles of bleomycin, etoposide, cisplatinumchemotherapy with or without retroperitoneal surgeryand cure rates with this approach are between 41% inpoor risk group and 92% in good risk group of patients.Cure rates are lower in relapsed and refractory patientsand many of them will die from the disease if not curedwith first line chemotherapy. High dose chemotherapy(HDCT) approach was used for the first time during the1980s. Progress in hematology allowed the possibility tokeep autologous haematopoietic stem cells alive ex-vivoat very low temperatures and use them to repopulatethe bone marrow after sub-lethal dose of intesivemyeloablative chemotherapy. Despite the fact thatthere is no positive randomized study to prove HDCTconcept, cure rates in relapsed TGCC are higher afterhigh dose therapy then in historical controls in studieswith conventional treatment. Here we review clinicalstudies in HDCT for TGCC, possibilities of mobilisingsufficient number of stem cells and future directions inthe treatment of this disease.

  11. Bladder accumulated dose in image-guided high-dose-rate brachytherapy for locally advanced cervical cancer and its relation to urinary toxicity

    Science.gov (United States)

    Zakariaee, Roja; Hamarneh, Ghassan; Brown, Colin J.; Gaudet, Marc; Aquino-Parsons, Christina; Spadinger, Ingrid

    2016-12-01

    The purpose of this study was to estimate locally accumulated dose to the bladder in multi-fraction high-dose-date (HDR) image-guided intracavitary brachytherapy (IG-ICBT) for cervical cancer, and study the locally-accumulated dose parameters as predictors of late urinary toxicity. A retrospective study of 60 cervical cancer patients who received five HDR IG-ICBT sessions was performed. The bladder outer and inner surfaces were segmented for all sessions and a bladder-wall contour point-set was created in MATLAB. The bladder-wall point-sets for each patient were registered using a deformable point-set registration toolbox called coherent point drift (CPD), and the fraction doses were accumulated. Various dosimetric and volumetric parameters were calculated using the registered doses, including r{{\\text{D}}n \\text{c{{\\text{m}}\\text{3}}}} (minimum dose to the most exposed n-cm3 volume of bladder wall), r V n Gy (wall volume receiving at least m Gy), and r\\text{EQD}{{2}n \\text{c{{\\text{m}}\\text{3}}}} (minimum equivalent biologically weighted dose to the most exposed n-cm3 of bladder wall), where n  =  1/2/5/10 and m  =  3/5/10. Minimum dose to contiguous 1 and 2 cm3 hot-spot volumes was also calculated. The unregistered dose volume histogram (DVH)-summed equivalent of r{{\\text{D}}n \\text{c{{\\text{m}}3}}} and r\\text{EQD}{{2}n \\text{c{{\\text{m}}3}}} parameters (i.e. s{{\\text{D}}n \\text{c{{\\text{m}}\\text{3}}}} and s\\text{EQD}{{2}n \\text{c{{\\text{m}}3}}} ) were determined for comparison. Late urinary toxicity was assessed using the LENT-SOMA scale, with toxicity Grade 0-1 categorized as Controls and Grade 2-4 as Cases. A two-sample t-test was used to identify the differences between the means of Control and Case groups for all parameters. A binomial logistic regression was also performed between the registered dose parameters and toxicity grouping. Seventeen patients were in the Case and 43 patients in the Control group. Contiguous

  12. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.

    Science.gov (United States)

    Ballester, Facundo; Carlsson Tedgren, Åsa; Granero, Domingo; Haworth, Annette; Mourtada, Firas; Fonseca, Gabriel Paiva; Zourari, Kyveli; Papagiannis, Panagiotis; Rivard, Mark J; Siebert, Frank-André; Sloboda, Ron S; Smith, Ryan L; Thomson, Rowan M; Verhaegen, Frank; Vijande, Javier; Ma, Yunzhi; Beaulieu, Luc

    2015-06-01

    In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) (192)Ir source and a virtual water phantom were designed, which can be imported into a TPS. A hypothetical, generic HDR (192)Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic (192)Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra(®) Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS™ ]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201)(3) voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR (192)Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then

  13. A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo, E-mail: Facundo.Ballester@uv.es [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Carlsson Tedgren, Åsa [Department of Medical and Health Sciences (IMH), Radiation Physics, Faculty of Health Sciences, Linköping University, Linköping SE-581 85, Sweden and Department of Medical Physics, Karolinska University Hospital, Stockholm SE-171 76 (Sweden); Granero, Domingo [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia E-46014 (Spain); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Institute of Technology, Melbourne, Victoria 3000 (Australia); Mourtada, Firas [Department of Radiation Oncology, Helen F. Graham Cancer Center, Christiana Care Health System, Newark, Delaware 19713 (United States); Fonseca, Gabriel Paiva [Instituto de Pesquisas Energéticas e Nucleares – IPEN-CNEN/SP, São Paulo 05508-000, Brazil and Department of Radiation Oncology (MAASTRO), GROW, School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Zourari, Kyveli; Papagiannis, Panagiotis [Medical Physics Laboratory, Medical School, University of Athens, 75 MikrasAsias, Athens 115 27 (Greece); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Siebert, Frank-André [Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel 24105 (Germany); Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); and others

    2015-06-15

    Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by

  14. Endocrine function following high dose proton therapy for tumors of the upper clivus

    Energy Technology Data Exchange (ETDEWEB)

    Slater, J.D.; Austin-Seymour, M.; Munzenrider, J.; Birnbaum, S.; Carroll, R.; Klibanski, A.; Riskind, P.; Urie, M.; Verhey, L.; Goitein, M.

    1988-09-01

    The endocrine status of patients receiving proton radiation for tumors of the upper clivus was reviewed to evaluate the effect of high dose treatment on the pituitary gland. The fourteen patients had chordomas or low grade chondrosarcomas and were all treated by the same techniques. The median tumor dose was 69.7 Cobalt Gray Equivalent (CGE) with a range from 66.6 to 74.4 CGE. (CGE is used because modulated protons have an RBE of 1.1 compared to 60Co). The daily fraction size was 1.8-2.1 CGE. The median follow-up time is 48 months, ranging from 30 to 68 months. All treatments were planned using a computerized multi-dimensional system with the position of the pituitary outlined on the planning CT scan. Review of the dose distribution indicated that the dose to the pituitary ranged from 60.5 to 72.3 CGE, with a median of 67.6 CGE. One female patient had decreased thyroid and gonadotropin function at the time of diagnosis and has been on hormone replacement since that time. The other three females were all pre-menopausal at the time of radiotherapy. At this time four patients (3 males and 1 female) have developed endocrine abnormalities 14 to 45 months after irradiation. All four had evidence of hypothyroidism and two have also developed corticotropin deficiency. The three males had decreased testosterone levels; the female patient developed amenorrhea and hyperprolactinemia. All four are asymptomatic with ongoing hormone replacement.

  15. Absorbed Dose and Collision Kerma Relationship for High-Energy Photons

    Science.gov (United States)

    Sibata, Claudio Hissao

    Historically, exposure has been used as an important quantity to specify X- or (gamma)- ray beams. For any photon beam the energy fluence is proportional to the exposure. Exposure can be calculated and/or measured if the spectrum of the beam is known and charged particle equilibrium (CPE) exists. For low energy photons (up to approximately 1 MeV), due to the existence of CPE, absorbed dose (D) is equal to the collision kerma (K(,c)). For megavoltage photons this equality is lost due to CPE failure, which also restricts the measurement of exposure. It is possible, though, to find a relationship between the absorbed dose and collision kerma when transient charged particle equilibrium (TCPE) exists. This basic idea was originally proposed by Roesch in 1958 and its refinement has been discussed by Attix in 1979 and 1983. The modified Roesch's formula which enables us to measure exposure even for high-energy photons is given by D = (beta) K(,c) (TURNEQ) K(,c) (1 + (mu)' ) where (mu)' is the effective linear attenuation coefficient and is the mean distance the secondary electrons carry kinetic energy in the direction of the photon beam while depositing it as absorbed dose. The symbol (beta) is the quotient of the absorbed dose and the collision kerma. The importance of Roesch's formula has been recognized and used implicitly in the recent dosimetry protocol of the AAPM (Task Group 21). However, the value used in the protocol is based on theoretical calculations which do not include photon scattering. As a result of the present effort the parameters (mu)' and have been determined experimentally, for the first time. The dependence of (beta) on several factors has been studied and (beta) has been obtained including the effects of scattering. Calculations were also performed for several photon energies and materials, using the Roesch method, which does not include photon scattering effects. Comparisons of measured and calculated values of show reasonable agreement.

  16. High dose rates obtained outside ISS in June 2015 during SEP event.

    Science.gov (United States)

    Dachev, T P; Tomov, B T; Matviichuk, Yu N; Dimitrov, Pl G; Bankov, N G

    2016-06-01

    The R3DR2 instrument performed measurements in the European Space Agency (ESA) EXPOSE-R2 platform outside the Russian "Zvezda" module of the International Space Station (ISS) in the period 24 October 2014-11 January 2016. It is the Liulin-type deposited energy spectrometer (DES) (Dachev et al., 2015a). Took place in November 2014, this was the first attempt to monitor a small solar energetic particle (SEP) event outside ISS using the Liulin-type DES (Dachev et al., 2015d). In this study, we describe the dosimetric characteristics of the largest SEP event, observed on 22 June 2015 with the R3DR2 instrument outside ISS. The main finding of this study is that SEP protons with a minimum energy of approximately 7MeV at the surface of the R3DR2 detector produced high dose rates, reaching >5000µGyh(-1), while the inner radiation belt maximum dose was at the level of 2200µGyh(-1). If a virtual external vehicle activity (EVA) was performed in the same period of the SEP maximum on 22 June 2015, the doses obtained in the skin of cosmonauts/astronauts can reach 2.84mGy after 6.5h, which is similar to the average absorbed dose inside ISS for 15days (Reitz et al., 2005). A comparison with other extreme events measured with Liulin-type instruments shows that SEPs similar to that observed on 22 June 2015 could be one of the most dangerous events for the cosmonauts/astronauts involved in EVA. Copyright © 2016 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  17. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    Science.gov (United States)

    Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-10-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.

  18. Effects of high dose coffee intake on aerobic power in dragon female athletes

    Directory of Open Access Journals (Sweden)

    Ramin Shabani

    2016-08-01

    Full Text Available Background : There are few studies that consider the effect of high doses of caffeine on aerobic power (VO2max. Also, to date, no study examined the effect of coffee intake on dragon boat paddler specifically on women. The purpose of this study was to investigate the effect of espresso coffee on improvement of aerobic power of dragon boat paddler. Material : Twenty women athletes of Guilan dragon bout team members of Malavan club of port city of Anzali (mean ±SD age, 23.60± 3.49 years; BMI,23.77±1.88kg/m2; body fat, 30.32±4.65% were recruited to this study, after they completed a primary test without consuming any coffee, they consumed 6mg/kg of coffee (espresso or decaffeinated and following that they completed two experimental trials. A randomized, double-blind, repeated-measures, design was employed whereby paddlers complete a 2000m paddling dragon boat ergo-meter. Results : Coffee could improve VO2max (Without coffee =74.40± QUOTE 4.99, Espresso coffee =90.10± QUOTE 6.19, Decaffeinated coffee =91.00± QUOTE 5.67, P≤ QUOTE 0.05. VO2max amount after exercise were significantly higher for both espresso coffee and decaffeinated coffee, when compared with without coffee condition. No significant differences were observed between espresso coffee and decaffeinated coffee (P≤ QUOTE 0.05. Conclusion : The present study shows that both high doses of caffeine (espresso coffee and decaffeinated coffee can enhance VO2max during aerobic exercise including 2000m dragon boat paddling. It seems that some compounds except caffeine in decaffeinated coffee can act improve VO2max. Further studies needed for considering the effect of high doses of coffee on endurance exercises. Also in other age ranges of women athletes and other sport athletes.

  19. Induction of regulatory T cells by high-dose gp96 suppresses murine liver immune hyperactivation.

    Directory of Open Access Journals (Sweden)

    Xinghui Li

    Full Text Available Immunization with high-dose heat shock protein gp96, an endoplasmic reticulum counterpart of the Hsp90 family, significantly enhances regulatory T cell (Treg frequency and suppressive function. Here, we examined the potential role and mechanism of gp96 in regulating immune-mediated hepatic injury in mice. High-dose gp96 immunization elicited rapid and long-lasting protection of mice against concanavalin A (Con A-and anti-CD137-induced liver injury, as evidenced by decreased alanine aminotransaminase (ALT levels, hepatic necrosis, serum pro-inflammatory cytokines (IFN-γ, TNF-α, and IL-6, and number of IFN-γ (+ CD4(+ and IFN-γ (+ CD8(+ T cells in the spleen and liver. In contrast, CD4(+CD25(+Foxp3(+ Treg frequency and suppressive function were both increased, and the protective effect of gp96 could be generated by adoptive transfer of Treg cells from gp96-immunized mice. In vitro co-culture experiments demonstrated that gp96 stimulation enhanced Treg proliferation and suppressive function, and up-regulation of Foxp3, IL-10, and TGF-β1 induced by gp96 was dependent on TLR2- and TLR4-mediated NF-κB activation. Our work shows that activation of Tregs by high-dose gp96 immunization protects against Con A- and anti-CD137-induced T cell-hepatitis and provides therapeutic potential for the development of a gp96-based anti-immune hyperactivation vaccine against immune-mediated liver destruction.

  20. Usefulness of high doses of glucocorticoids and hyperbaric oxygen therapy in sudden sensorineural hearing loss treatment.

    Science.gov (United States)

    Narozny, Waldemar; Sicko, Zdzislaw; Przewozny, Tomasz; Stankiewicz, Czeslaw; Kot, Jacek; Kuczkowski, Jerzy

    2004-11-01

    We investigated the effect of pharmacologic (steroids, vasodilators, vitamins, and Betaserc) and hyperbaric oxygen therapy on patients with sudden sensorineural hearing loss. The pharmacologic arm of the study consisted of 52 patients with defined sudden sensorineural hearing loss treated simultaneously in the ENT Department and National Center for Hyperbaric Medicine of the Medical University of Gdansk, Poland, from 1997 to 2000 (Group A). The hyperbaric oxygen therapy consisted of exposure to 100% oxygen at a pressure of 250 kPa for a total of 60 minutes in a multiplace hyperbaric chamber. The control group included 81 patients with defined sudden sensorineural hearing loss treated in the ENT Department, Medical University of Gdansk, from 1980 to 1996 (Group B). Both groups were comparable regarding the age of the patients, season of hearing loss occurrence, tinnitus and vestibular symptom frequency, delay before therapy, and average threshold loss before the start of treatment. The treatment results (hearing gain) were estimated using pure-tone audiometry. We retrospectively analyzed the audiograms of all patients. Patients from Group A (blood flow-promoting drugs, glucocorticoids in high doses, betahistine, and hyperbaric oxygen therapy) showed significantly better recovery of hearing levels compared with those from Group B (blood flow-promoting drugs and glucocorticoids in low doses) at seven frequencies (500, 1,000, 2,000, 3,000, 4,000, 6,000, and 8,000 Hz) (p < 0.05) and four groups of frequencies (pure-tone average, high-tone average, pure middle-tone average, and overall average) (p < 0.05). Percentage hearing gain in all investigated frequencies was also better in Group A versus Group B, and the differences were statistically significant (p < 0.05). We conclude that hyperbaric oxygen therapy with high doses of glucocorticoids improves the results of conventional sudden sensorineural hearing loss treatment and should be recommended. In addition, the best

  1. Peripheral arterial disease in a female using high-dose combined oral contraceptive pills

    Directory of Open Access Journals (Sweden)

    P Pallavee

    2013-01-01

    Full Text Available The association between oral contraceptive (OC pills and vascular diseases is well-known, although, the present generation of pills is considered to be relatively safer in this regard. Hormonal treatment for severe abnormal uterine bleeding is usually considered after ruling out malignancy, when such bleeding is resistant to all other forms of treatment. We report a case of severe peripheral arterial disease in a female, who had been on high-dose OC pills for an extended period of time for severe uterine bleeding.

  2. High dose-rate brachytherapy source position quality assurance using radiochromic film.

    Science.gov (United States)

    Evans, M D C; Devic, S; Podgorsak, E B

    2007-01-01

    Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance.

  3. Desensitization Using Bortezomib and High-dose Immunoglobulin Increases Rate of Deceased Donor Kidney Transplantation.

    Science.gov (United States)

    Jeong, Jong Cheol; Jambaldorj, Enkthuya; Kwon, Hyuk Yong; Kim, Myung-Gyu; Im, Hye Jin; Jeon, Hee Jung; In, Ji Won; Han, Miyeun; Koo, Tai Yeon; Chung, Junho; Song, Eun Young; Ahn, Curie; Yang, Jaeseok

    2016-02-01

    Combination therapy of intravenous immunoglobulin (IVIG) and rituximab showed a good transplant rate in highly sensitized wait-listed patients for deceased donor kidney transplantation (DDKT), but carried the risk of antibody-mediated rejection. The authors investigated the impact of a new combination therapy of bortezomib, IVIG, and rituximab on transplantation rate.This study was a prospective, open-labeled clinical trial. The desensitization regimen consisted of 2 doses of IVIG (2  g/kg), a single dose of rituximab (375  mg/m), and 4 doses of bortezomib (1.3  mg/m). The transplant rate was analyzed. Anti-Human leukocyte antigen (HLA) DRB antibodies were determined by a Luminex solid-phase bead assay at baseline and after 2, 3, and 6 months in the desensitized patients.There were 19 highly sensitized patients who received desensitization and 17 patients in the control group. Baseline values of class I and II panel reactive antibody (%, peak mean fluorescence intensity) were 83  ±  16.0 (14952  ±  5820) and 63  ±  36.0 (10321  ±  7421), respectively. Deceased donor kidney transplantation was successfully performed in 8 patients (42.1%) in the desensitization group versus 4 (23.5%) in the control group. Multivariate time-varying covariate Cox regression analysis showed that desensitization increased the probability of DDKT (hazard ratio, 46.895; 95% confidence interval, 3.468-634.132; P = 0.004). Desensitization decreased mean fluorescence intensity values of class I panel reactive antibody by 15.5% (20.8%) at 2 months. In addition, a liberal mismatch strategy in post hoc analysis increased the benefit of desensitization in donor-specific antibody reduction. Desensitization was well tolerated, and acute rejection occurred only in the control group.In conclusion, a desensitization protocol using bortezomib, high-dose IVIG, and rituximab increased the DDKT rate in highly sensitized, wait-listed patients.

  4. Effect of high-dose intravenous vitamin C on inflammation in cancer patients

    Directory of Open Access Journals (Sweden)

    Mikirova Nina

    2012-09-01

    Full Text Available Abstract Background An inflammatory component is present in the microenvironment of most neoplastic tissues. Inflammation and elevated C-reactive protein (CRP are associated with poor prognosis and decreased survival in many types of cancer. Vitamin C has been suggested as having both a preventative and therapeutic role in a number of pathologies when administered at much higher-than-recommended dietary allowance levels. Since in vitro studies demonstrated inhibition of pro-inflammatory pathways by millimolar concentrations of vitamin C, we decided to analyze the effects of high dose IVC therapy in suppression of inflammation in cancer patients. Methods 45 patients with prostate cancer, breast cancer, bladder cancer, pancreatic cancer, lung cancer, thyroid cancer, skin cancer and B-cell lymphoma were treated at the Riordan Clinic by high doses of vitamin C (7.5 g -50 g after standard treatments by conventional methods. CRP and tumor markers were measured in serum or heparin-plasma as a routine analysis. In addition, serum samples were collected before and after the IVCs for the cytokine kit tests. Results According to our data positive response to treatment, which was demonstrated by measurements of C- reactive protein, was found in 75% of patients and progression of the inflammation in 25% of patients. IVC treatments on all aggressive stage cancer patients showed the poor response of treatment. There was correlation between tumor markers (PSA, CEA, CA27.29 and CA15-3 and changes in the levels of C-reactive protein. Our test of the effect of IVC on pro-inflammatory cytokines demonstrated that inflammation cytokines IL-1α, IL-2, IL-8, TNF-α, chemokine eotaxin and CRP were reduced significantly after treatments. Conclusions The high dose intravenous ascorbic acid therapy affects C-reactive protein levels and pro-inflammation cytokines in cancer patients. In our study, we found that modulation of inflammation by IVC correlated with decreases

  5. Can anisodamine be a potential substitute for high-dose atropine in cases of organophosphate poisoning?

    Science.gov (United States)

    Wang, W; Chen, Q-F; Ruan, H-L; Chen, K; Chen, B; Wen, J-M

    2014-11-01

    A case of organophosphate (OP) poisoning was admitted to the emergency room. The patient accepted treatment with pralidoxime (PAM), atropine, and supporting therapy. It was observed that even after 22 h after treatment, 960 mg of atropine was not enough for the patient to be atropinized. However, a 160-mg follow-up treatment of anisodamine was quite enough for atropinization after 4 h. As a case report, more studies are required before any definite conclusion can be reached regarding the use of anisodamine as a potential substitute for high-dose atropine in cases of OP poisoning.

  6. A high throughput passive dosing format for the Fish Embryo Acute Toxicity test

    DEFF Research Database (Denmark)

    Vergauwen, Lucia; Nørgaard Schmidt, Stine; Stinckens, Evelyn

    2015-01-01

    High throughput testing according to the Fish Embryo Acute Toxicity (FET) test (OECD Testing Guideline 236) is usually conducted in well plates. In the case of hydrophobic test substances, sorptive and evaporative losses often result in declining and poorly controlled exposure conditions. Therefore......, our objective was to improve exposure conditions in FET tests by evaluating a passive dosing format using silicone O-rings in standard 24-well polystyrene plates. We exposed zebrafish embryos to a series of phenanthrene concentrations until 120 h post fertilization (hpf), and obtained a linear...

  7. A double-blind, placebo controlled trial of high-dose lecithin in Alzheimer's disease.

    OpenAIRE

    Little, A.; Levy, R.; Chuaqui-Kidd, P; Hand, D

    1985-01-01

    The first long-term double-blind placebo controlled trial of high dose lecithin in senile dementia of the Alzheimer type is reported. Fifty one subjects were given 20-25 g/day of purified soya lecithin (containing 90% phosphatidyl plus lysophosphatidyl choline) for six months and followed up for at least a further six months. Plasma choline levels were monitored throughout the treatment period. There were no differences between the placebo group and the lecithin group but there was an improve...

  8. Radiomenolysis of the endometrium by high-dose iridium-192 irradiation- clinical and cytomorphologic results

    Energy Technology Data Exchange (ETDEWEB)

    Kucera, H.; Huber, H.; Weghaupt, K.

    1984-04-01

    423 patients with benign recurrent uterine bleeding resistant to other therapy were treated by intracavitary radiotherapy. In all cases there was a contraindication for the operative removal of the uterus. Since 1980 radiomenolysis was performed by high-dose Iridium-192 irradiation (afterloading technique). In 94.3% of our cases with Radium-226 irradiation the bleeding could be treated successfully. Side effects of the irradiation occurred only in a minimal and neglectible percentage. In all cases irradiated with Iridium-192 the bleeding stopped after treatment. Side effects could not be observed. Therefore the intrauterine contact-irradiation therapy with high-dose Iridium-192 should be remembered in cases of uterine bleeding resistant to hormonal therapy or in cases of high risk for operation. With the afterloading device the molestation for the patients could be reduced to a minimum. By intrauterine exfoliative smear performed before and after irradiation the cytomorphologic effect of an Iridium-192 afterloading irradiation was demonstrated. The examinations showed that the cytologic findings were characteristic for the effect if ionizing radiation of the histologically unchanged, not radiosensitive, normal cylindrical epithelium. A marked cellular diathesis and augmentation of size of nuclei and plasma is a characteristic result of the irradiation with Iridium-192.

  9. Predictive Modeling of Tacrolimus Dose Requirement Based on High-Throughput Genetic Screening.

    Science.gov (United States)

    Damon, C; Luck, M; Toullec, L; Etienne, I; Buchler, M; Hurault de Ligny, B; Choukroun, G; Thierry, A; Vigneau, C; Moulin, B; Heng, A-E; Subra, J-F; Legendre, C; Monnot, A; Yartseva, A; Bateson, M; Laurent-Puig, P; Anglicheau, D; Beaune, P; Loriot, M A; Thervet, E; Pallet, N

    2017-04-01

    Any biochemical reaction underlying drug metabolism depends on individual gene-drug interactions and on groups of genes interacting together. Based on a high-throughput genetic approach, we sought to identify a set of covariant single-nucleotide polymorphisms predictive of interindividual tacrolimus (Tac) dose requirement variability. Tac blood concentrations (Tac C0 ) of 229 kidney transplant recipients were repeatedly monitored after transplantation over 3 mo. Given the high dimension of the genomic data in comparison to the low number of observations and the high multicolinearity among the variables (gene variants), we developed an original predictive approach that integrates an ensemble variable-selection strategy to reinforce the stability of the variable-selection process and multivariate modeling. Our predictive models explained up to 70% of total variability in Tac C0 per dose with a maximum of 44 gene variants (p-value <0.001 with a permutation test). These models included molecular networks of drug metabolism with oxidoreductase activities and the multidrug-resistant ABCC8 transporter, which was found in the most stringent model. Finally, we identified an intronic variant of the gene encoding SLC28A3, a drug transporter, as a key gene involved in Tac metabolism, and we confirmed it in an independent validation cohort. © 2016 The American Society of Transplantation and the American Society of Transplant Surgeons.

  10. High-Dose Risperidone Induced Latent Syndrome of Inappropriate Antidiuretic Hormone Secretion With Seizure Presentation.

    Science.gov (United States)

    Lee, Yen-Feng; Tsai, Chia-Kuang; Liang, Chih-Sung

    2015-01-01

    We report a case of a patient with schizophrenia treated with high-dose risperidone, who developed syndrome of inappropriate antidiuretic hormone secretion (SIADH) with the only early symptom of tonic-clonic seizures. A 40-year-old woman with schizophrenia was treated with risperidone 2 mg/d. After the dosage was titrated to 6 mg/d, she experienced generalized seizure attacks. Laboratory screening revealed that the serum sodium level was 106 mmol/L, the urine sodium concentration was 41.2 mmol/L, and the urine osmolality was 371 mOsm/kg H2O. A diagnosis of SIADH was made, and risperidone was stopped. After infusion of hypertonic saline, the serum sodium returned to normal levels, and seizures did not recur. In this patient, SIADH advanced in a latent manner because the first and only symptom of SIADH was seizure attack. High-dose risperidone treatment is the most probable cause, and the mechanisms may be related to risperidone's high affinity for the 5-hydroxytryptamine 2A and dopamine 2 receptors. Patients with schizophrenia can display atypical features of medical illnesses. Routine physical and laboratory examinations may prevent silent disease progression.

  11. SU-E-T-383: Can Stereotactic Body Radiotherapy Mimic the Dose Distribution of High-Dose-Rate Tandem and Ovoids/ring Brachytherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Park, S; Demanes, J; Kamrava, M [UCLA School of Medicine, Los Angeles, CA (United States); Scanderbeg, D [UCSD Medical Center, La Jolla, CA (United States)

    2014-06-01

    Purpose: To investigate whether stereotactic body radiotherapy (SBRT) using volumetric modulated arc therapy (VMAT) can mimic the dosimetry of tandem and ovoids/ring brachytherapy. Methods: We selected 5 patients treated with 3D-CT based high-dose rate (HDR) brachytherapy using 4 tandem and ovoid and 1 tandem and ring case. Manual optimization based on the Manchester system followed by graphical optimization (Nucletron Oncentra MasterPlan or Varian BrachyVision) was performed to deliver 6.0 Gy per fraction to a high-risk CTV while maintaining dose to organs at risk (OAR) below the ABS recommendations. For theoretical SBRT plans, CT images and OAR contours from the HDR plans were imported into Eclipse (Varian). The SBRT plan was created to mimic the heterogeneity of HDR plans by using a simultaneous integrated boost technique to match the V100, V150, and V200 isodose volumes from HDR. The OAR Dmax from HDR was used to define the OAR dose constraints for SBRT. Target coverage, dose spill-out, and OAR doses (D0.1cc, D1cc, and D2cc) between the HDR and SBRT plans were compared for significance using a two-tail paired ttest. Results: The mean isodose volumes for HDR vs. SBRT were 29.4 cc vs. 29.0 cc (V200, p = 0.674), 49.2 cc vs. 56.3 cc (V150, p = 0.017), 95.4 cc vs. 127.7 cc (V100, p = 0.001), and 271.9 cc vs. 581.6 cc (V50, p = 0.001). The D2cc to OAR for HDR vs. SBRT was 71.6% vs. 96.2% (bladder, p = 0.002), 69.2% vs. 101.7% (rectum, p = 0.0003), and 56.9% vs. 68.6% (sigmoid, p = 0.004). Conclusion: SBRT with VMAT can provide similar dose target coverage (V200), but dose spill-out and doses to OAR were statistically significantly higher than HDR. This study clearly demonstrated that brachytherapy can not be substituted with SBRT in gynecologic cervical cancer treatment.

  12. HIGH-DOSE CHEMOTHERAPY WITH STEM-CELL REINFUSION AND GROWTH-FACTOR SUPPORT FOR SOLID TUMORS

    NARCIS (Netherlands)

    DEVRIES, EGE; DEGRAAF, H; VANDERGRAAF, WTA; MULDER, NH; Boonstra, A.

    1995-01-01

    With the help of stem cell reinfusion and hematopoietic growth factors, it is possible to get up to a ten-fold dose increase for certain chemotherapeutic drugs, A number of reasons may have made high-dose chemotherapy less dangerous and the fore more acceptable in a more upfront treatment setting, O

  13. Computational fluid dynamics (CFD) assisted performance evaluation of the Twincer (TM) disposable high-dose dry powder inhaler

    NARCIS (Netherlands)

    de Boer, Anne H.; Hagedoorn, Paul; Woolhouse, Robert; Wynn, Ed

    Objectives To use computational fluid dynamics (CFD) for evaluating and understanding the performance of the high-dose disposable Twincer (TM) dry powder inhaler, as well as to learn the effect of design modifications on dose entrainment, powder dispersion and retention behaviour. Methods Comparison

  14. High-dose rifampicin kills persisters, shortens treatment duration, and reduces relapse rate in vitro and in vivo.

    Science.gov (United States)

    Hu, Yanmin; Liu, Alexander; Ortega-Muro, Fatima; Alameda-Martin, Laura; Mitchison, Denis; Coates, Anthony

    2015-01-01

    Although high-dose rifampicin holds promise for improving tuberculosis control by potentially shortening treatment duration, these effects attributed to eradication of persistent bacteria are unclear. The presence of persistent Mycobacterium tuberculosis was examined using resuscitation promoting factors (RPFs) in both in vitro hypoxia and in vivo murine tuberculosis models before and after treatment with incremental doses of rifampicin. Pharmacokinetic parameters and dose-dependent profile of rifampicin in the murine model were determined. The Cornell mouse model was used to test efficacy of high-dose rifampicin in combination with isoniazid and pyrazinamide and to measure relapse rate. There were large numbers of RPF-dependent persisters in vitro and in vivo. Stationary phase cultures were tolerant to rifampicin while higher concentrations of rifampicin eradicated plate count positive but not RPF-dependent persistent bacteria. In murine infection model, incremental doses of rifampicin exhibited a dose-dependent eradication of RPF-dependent persisters. Increasing the dose of rifampicin significantly reduced the risk of antibiotic resistance emergence. In Cornell model, mice treated with high-dose rifampicin regimen resulted in faster visceral clearance; organs were M. tuberculosis free 8 weeks post-treatment compared to 14 weeks with standard-dose rifampicin regimen. Organ sterility, plate count and RPF-dependent persister negative, was achieved. There was no disease relapse compared to the standard dose regimen (87.5%). High-dose rifampicin therapy results in eradication of RPF-dependent persisters, allowing shorter treatment duration without disease relapse. Optimizing rifampicin to its maximal efficacy with acceptable side-effect profiles will provide valuable information in human studies and can potentially improve current tuberculosis chemotherapy.

  15. High dose rifampicin kills persisters, shortens treatment duration and reduces relapse rate in vitro and in vivo

    Directory of Open Access Journals (Sweden)

    Yanmin eHu

    2015-06-01

    Full Text Available Although high-dose rifampicin holds promise for improving tuberculosis control by potentially shortening treatment duration, these effects attributed to eradication of persistent bacteria are unclear. The presence of persistent M. tuberculosis was examined using resuscitation promoting factors (RPF in both in vitro hypoxia and in vivo murine tuberculosis models before and after treatment with incremental doses of rifampicin. Pharmacokinetic parameters and dose-dependent profile of rifampicin in the murine model were determined. The Cornell mouse model was used to test efficacy of high-dose rifampicin in combination with isoniazid and pyrazinamide and to measure relapse rate. There were large numbers of RPF-dependent persisters in vitro and in vivo. Stationary phase cultures were tolerant to rifampicin while higher concentrations of rifampicin eradicated plate count positive but not RPF-dependent persistent bacteria. In murine infection model, incremental doses of rifampicin exhibited a dose-dependent eradication of RPF-dependent persisters. Increasing the dose of rifampicin significantly reduced the risk of antibiotic resistance emergence. In Cornell model, mice treated with high-dose rifampicin regimen resulted in faster visceral clearance; organs were M. tuberculosis free 8 weeks post-treatment compared to 14 weeks with standard-dose rifampicin regimen. Organ sterility, plate count and RPF-dependent persister negative, was achieved. There was no disease relapse compared to the standard dose regimen (87.5%. High-dose rifampicin therapy results in eradication of RPF-dependent persisters, allowing shorter treatment duration without disease relapse. Optimising rifampicin to its maximal efficacy with acceptable side-effect profiles will provide valuable information in human studies and can potentially improve current tuberculosis chemotherapy.

  16. Report on MPACT Deliverable M3FT-16LA040106035 (High Dose Evaluation of Improved PDT Detector Pod)

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-18

    This report provides the results for the initial high gamma dose tests for the boron-10 plate detector that was fabricated by PDT, Inc. under contract to LANL The specifications for the detector were developed using MCNP code simulations and prior experimental tests at LANL. The goal in the development was to provide high neutron detection efficiency together with gamma-ray resistance at very high gamma dose levels that are characteristic of the electrochemical fuel processing activity.

  17. CORRELATION OF LOCAL FAILURE WITH MEASURES OF DOSE INSUFFICIENCY IN THE HIGH-DOSE SINGLE-FRACTION TREATMENT OF BONY METASTASES

    Science.gov (United States)

    Lovelock, D. Michael; Zhang, Zhigang; Jackson, Andrew; Keam, Jennifer; Bekelman, Justin; Bilsky, Mark; Lis, Eric; Yamada, Yoshiya

    2011-01-01

    Purpose In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials The minimum doses received by the hottest 100%, 98%, and 95% (Dmin, D98, and D95) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18–24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12–14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV Dmin, D98, and D95 for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for Dmin, D98, and D95 were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions The results indicate that Dmin, D98, and D95 may be important risk factors for local failure. No local failures in any histology were observed when Dmin was >15 Gy, suggesting that this metric may be an important predictor of local control. PMID:20350795

  18. Phase stability and microstructures of high entropy alloys ion irradiated to high doses

    Science.gov (United States)

    Xia, Songqin; Gao, Michael C.; Yang, Tengfei; Liaw, Peter K.; Zhang, Yong

    2016-11-01

    The microstructures of AlxCoCrFeNi (x = 0.1, 0.75 and 1.5 in molar ratio) high entropy alloys (HEAs) irradiated at room temperature with 3 MeV Au ions at the highest fluence of 105, 91, and 81 displacement per atom, respectively, were studied. Transmission electron microscopy (TEM) and high-resolution TEM (HRTEM) analyses show that the initial microstructures and phase composition of all three alloys are retained after ion irradiation and no phase decomposition is observed. Furthermore, it is demonstrated that the disordered face-centered cubic (FCC) and disordered body-centered cubic (BCC) phases show much less defect cluster formation and structural damage than the NiAl-type ordered B2 phase. This effect is explained by higher entropy of mixing, higher defect formation/migration energies, substantially lower thermal conductivity, and higher atomic level stress in the disordered phases.

  19. High-dose benzodiazepine dependence: a qualitative study of patients' perception on cessation and withdrawal.

    Science.gov (United States)

    Liebrenz, Michael; Gehring, Marie-Therese; Buadze, Anna; Caflisch, Carlo

    2015-05-13

    Benzodiazepine withdrawal syndrome has been reported following attempts to withdraw even from low or therapeutic doses and has been compared to barbiturate and alcohol withdrawal. This experience is known to deter patients from future cessation attempts. Research on other psychotropic substances shows that the reasons and motivations for withdrawal attempts - as well as the experiences surrounding those attempts - at least partially predict future efforts at discontinuation as well as relapse. We therefore aimed to qualitatively explore what motivates patients to discontinue this medication as well as to examine their experiences surrounding previous and current withdrawal attempts and treatment interventions in order to positively influence future help-seeking behavior and compliance. To understand these patients better, we conducted a series of 41 unstructured, narrative, in-depth interviews among adult Swiss patients with a long-term dependent use of benzodiazepines in doses equivalent to more than 40 mg diazepam per day and/or otherwise problematic use (mixing benzodiazepines, escalating dosage, recreational use or illegal purchase). Mayring's qualitative content analysis was used to evaluate findings. These high-dose benzodiazepine-dependent patients decision to change consumption patterns were affected by health concerns, the feeling of being addicted and social factors. Discontinuation attempts were frequent and not very successful with fast relapse. Withdrawal was perceived to be a difficult, complicated, and highly unpredictable process. The first attempt at withdrawal occurred at home and typically felt better than at the clinic. Inpatient treatment was believed to be more effective with long term treatment (approaches) than short term. Patients preferred gradual reduction of usage to abrupt cessation (and had experienced both). While no clear preferences for withdrawal were found for benzodiazepines with specific pharmacokinetic properties, participants

  20. High-dose infliximab for treatment of pediatric ulcerative colitis: A survey of clinical practice

    Institute of Scientific and Technical Information of China (English)

    Roy Nattiv; Janet M Wojcicki; Elizabeth A Garnett; Neera Gupta; Melvin B Heyman

    2012-01-01

    AIM:TO assess attitudes and trends regarding the use of high-dose infliximab among pediatric gastroenterologists for treatment of pediatric ulcerative colitis (UC).METHODS:A 19-item survey was distributed to subscribers of the pediatric gastroenterology (PEDSGI)listserv.Responses were submitted anonymously and results compiled in a secure website.RESULTS:A total of 113 subscribers (88% based in the United States) responded (101 pediatric gastroenterology attendings and 12 pediatric gastroenterology fellows).There were 46% in academic medical institutions and 39% in hospital-based practices.The majority (91%) were treating >10 patients with UC; 13% were treating >100 patients with UC; 91% had prescribed infliximab (IFX) 5 mg/kg for UC; 72% had prescribed IFX 10 mg/kg for UC.Using a 5-point Likert scale,factors that influenced the decision not to increase IFX dosing in patients with UC included:"improvement on initial dose of IFX" (mean:3.88) and "decision to move to colectomy" (3.69).Lowest mean Likert scores were:"lack of guidelines or literature regarding increased IFX