WorldWideScience

Sample records for high air flow

  1. Flow structure around high-speed train in open air

    Institute of Scientific and Technical Information of China (English)

    田红旗; 黄莎; 杨明智

    2015-01-01

    According to the analysis of the turbulent intensity level around the high-speed train, the maximum turbulent intensity ranges from 0.2 to 0.5 which belongs to high turbulent flow. The flow field distribution law was studied and eight types of flow regions were proposed. They are high pressure with air stagnant region, pressure decreasing with air accelerating region, low pressure with high air flow velocity region I, turbulent region, steady flow region, low pressure with high air flow velocity region II, pressure increasing with air decelerating region and wake region. The analysis of the vortex structure around the train shows that the vortex is mainly induced by structures with complex mutation and large curvature change. The head and rear of train, the underbody structure, the carriage connection section and the wake region are the main vortex generating sources while the train body with even cross-section has rare vortexes. The wake structure development law studied lays foundation for the train drag reduction.

  2. Flow and containment characteristics of an air-curtain fume hood operated at high temperatures.

    Science.gov (United States)

    Chen, Jia-Kun; Huang, Rong Fung; Hsin, Pei-Yi; Hsu, Ching Min; Chen, Chun-Wann

    2012-01-01

    The flow and leakage characteristics of the air-curtain fume hood under high temperature operation (between 100°C and 250°C) were studied. Laser-assisted flow visualization technique was used to reveal the hot plume movements in the cabinet and the critical conditions for the hood-top leakage. The sulfur hexafluoride tracer-gas concentration test method was employed to examine the containment spillages from the sash opening and the hood top. It was found that the primary parameters dominating the behavior of the flow field and hood performance are the sash height and the suction velocity as an air-curtain hood is operated at high temperatures. At large sash height and low suction velocity, the air curtain broke down and accompanied with three-dimensional flow in the cabinet. Since the suction velocity was low and the sash opening was large, the makeup air drawn down from the hood top became insufficient to counter act the rising hot plume. Under this situation, containment leakage from the sash opening and the hood top was observed. At small sash opening and high suction velocity, the air curtain presented robust characteristics and the makeup air flow from the hood top was sufficiently large. Therefore the containment leakages from the sash opening and the hood top were not observed. According to the results of experiments, quantitative operation sash height and suction velocity corresponding to the operation temperatures were suggested.

  3. Air flow patterns and noise analysis inside high speed angular contact ball bearings

    Institute of Scientific and Technical Information of China (English)

    翟强; 闫柯; 张优云; 朱永生; 王亚泰

    2015-01-01

    The vortex formed around the rolling ball and the high pressure region formed around the ball−raceway contact zone are the principle factors that barricades the lubricant entering the bearing cavity, and further causes improper lubrication. The investigation of the air phase flow inside the bearing cavity is essential for the optimization of the oil−air two-phase lubrication method. With the revolutionary reference frame describing the bearing motion, a highly precise air phase flow model inside the angular contact ball bearing cavity was build up. Comprehensive factors such as bearing revolution, ball rotation, and cage structure were considered to investigate the influences on the air phase flow and heat transfer efficiency. The aerodynamic noise was also analyzed. The result shows that the ball spinning leads to the pressure rise and uneven pressure distribution. The air phase velocity, pressure and cage heat transfer efficiency increase as the revolving speed increases. The operating noise is largely due to the impact of the high speed external flow on the bearing. When the center of the oil−air outlet fixes near the inner ring, the aerodynamic noise is reduced. The position near the inner ring on the bigger axial side is the ideal position to fix the lubricating device for the angular contact ball bearing.

  4. Numerical simulation of air flow field in high-pressure fan with splitter blades

    Institute of Scientific and Technical Information of China (English)

    Jianfeng LI; Junfu LU; Hai ZHANG; Qing LIU; Guangxi YUE

    2008-01-01

    For a deeper understanding of the flow char-acteristics in the high-pressure centrifugal blower of a fan of Model 9-26 with splitter blades, a three dimensional (3-D) numerical simulation of air flows in the fan was con-ducted with FLUENT software. The standard k-ε tur-bulent model and unstructured grids were used. The computational fluid dynamics (CFD) results showed that the performance of a fan could be improved by adding the splitter blades in the channel among the leaf blades. Under operational conditions, with the presence of splitter blades, the air flow rate of the fan increased about 5% and the total pressure at the outlet of the fan increased about 10% on average. It was also found that the length of the splitter blades affected the air flow and pressure drop. There is an optimal value for the length. The simulation results provide helpful information for improving the fan performance.

  5. Flow in air conditioned rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1974-01-01

    Flow in air conditioned r ooms is examined by means of model experiments . The different gearnetries giving unsteady, steady three- dimensional and steady twodimensional flow are determined . Velacity profiles and temperature profiles are measured in some of the geometries. A numerical solution...... of the flow equations is demonstrated and the flow in air conditioned rooms in case of steady two dimensional flow is predi cted. Compari son with measured results is shown i n the case of small Archimedes numbers, and predictions are shown at high Archimedes numbers. A numerical prediction of f low and heat...

  6. High accuracy acoustic relative humidity measurement in duct flow with air.

    Science.gov (United States)

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

  7. High temperature air-blown woody biomass gasification model for the estimation of an entrained down-flow gasifier.

    Science.gov (United States)

    Kobayashi, Nobusuke; Tanaka, Miku; Piao, Guilin; Kobayashi, Jun; Hatano, Shigenobu; Itaya, Yoshinori; Mori, Shigekatsu

    2009-01-01

    A high temperature air-blown gasification model for woody biomass is developed based on an air-blown gasification experiment. A high temperature air-blown gasification experiment on woody biomass in an entrained down-flow gasifier is carried out, and then the simple gasification model is developed based on the experimental results. In the experiment, air-blown gasification is conducted to demonstrate the behavior of this process. Pulverized wood is used as the gasification fuel, which is injected directly into the entrained down-flow gasifier by the pulverized wood banner. The pulverized wood is sieved through 60 mesh and supplied at rates of 19 and 27kg/h. The oxygen-carbon molar ratio (O/C) is employed as the operational condition instead of the air ratio. The maximum temperature achievable is over 1400K when the O/C is from 1.26 to 1.84. The results show that the gas composition is followed by the CO-shift reaction equilibrium. Therefore, the air-blown gasification model is developed based on the CO-shift reaction equilibrium. The simple gasification model agrees well with the experimental results. From calculations in large-scale units, the cold gas is able to achieve 80% efficiency in the air-blown gasification, when the woody biomass feedrate is over 1000kg/h and input air temperature is 700K.

  8. High accuracy acoustic relative humidity measurement in duct flow with air

    OpenAIRE

    Cees van der Geld; Twan Wernaart; Mart Grooten; Wilhelm van Schaik

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0–12 m/s with an error of ±0.13 m/s, temp...

  9. Air Traffic Flow Management

    CERN Document Server

    Ganu, Hrishikesh V

    2008-01-01

    Air Traffic Flow Management is the regulation of air traffic in order to avoid exceeding airport or flight sector capacity in handling traffic, and to ensure that available capacity is used efficiently. We have tried to explore the logic behind the claims by Bertsimas et.al about integral solutions to the LP relaxation of the Traffic Flow Management Problem(TFMP). Polyhedral theory only indicates that the stronger TFMP formulation of Bertsimas et.al might lead to integral solutions in some cases. Our computations indicate that the encouraging results reported by Bertsimas et.al are not merely fortuitous or due to their specific data set. Indeed, we found that the TFMP had integral solutions even in case of artificial data sets generated to include severe conflicts in the flight schedules. In our limited tests with 4-5 scenarios, we obtained non-integral solutions only once. This is of significant practical importance because, the LP relaxation can be solved even on small machines with low memory and processor...

  10. Air filtration in the free molecular flow regime: a review of high-efficiency particulate air filters based on carbon nanotubes.

    Science.gov (United States)

    Li, Peng; Wang, Chunya; Zhang, Yingying; Wei, Fei

    2014-11-01

    Air filtration in the free molecular flow (FMF) regime is important and challenging because a higher filtration efficiency and lower pressure drop are obtained when the fiber diameter is smaller than the gas mean free path in the FMF regime. In previous studies, FMF conditions have been obtained by increasing the gas mean free path through reducing the pressure and increasing the temperature. In the case of carbon nanotubes (CNTs) with nanoscale diameters, it is possible to filtrate in the FMF regime under normal conditions. This paper reviews recent progress in theoretical and experimental studies of air filtration in the FMF regime. Typical structure models of high-efficiency particulate (HEPA) air filters based on CNTs are introduced. The pressure drop in air filters operated in the FMF regime is less than that predicted by the conventional air filtration theory. The thinnest HEPA filters fabricated from single-walled CNT films have an extremely low pressure drop. CNT air filters with a gradient nanostructure are shown to give a much better filtration performance in dynamic filtration. CNT air filters with a hierarchical structure and an agglomerated CNT fluidized bed air filter are also introduced. Finally, the challenges and opportunities for the application of CNTs in air filtration are discussed.

  11. Calculation and measurement of a neutral air flow velocity impacting a high voltage capacitor with asymmetrical electrodes

    Directory of Open Access Journals (Sweden)

    M. Malík

    2014-01-01

    Full Text Available This paper deals with the effects surrounding phenomenon of a mechanical force generated on a high voltage asymmetrical capacitor (the so called Biefeld-Brown effect. A method to measure this force is described and a formula to calculate its value is also given. Based on this the authors derive a formula characterising the neutral air flow velocity impacting an asymmetrical capacitor connected to high voltage. This air flow under normal circumstances lessens the generated force. In the following part this velocity is measured using Particle Image Velocimetry measuring technique and the results of the theoretically calculated velocity and the experimentally measured value are compared. The authors found a good agreement between the results of both approaches.

  12. A new concept of high flow rate non-thermal plasma reactor for air treatment

    Energy Technology Data Exchange (ETDEWEB)

    Goujard, V.; Tatibouet, J.M. [Univ. de Poitiers, Poitiers (France). Centre national de la recherche scientifique, Laboratoire de Catalyse en Chimie Organique

    2010-07-01

    Although several non-thermal plasma reactors have been tested for air treatment at the laboratory scale, up-scaling to pilot or industrial scale remains a challenge because several parameters must be considered, such as hydrodynamic behaviour, maximum voltage in an industrial environment, and maintenance of the system. This paper presented a newly developed reactor which consists to a DBD plasma generated on individual supports that could be directly inserted in gas pipes where air flow must be treated. Elimination of 40 percent of 15 ppm of propene was obtained with a energy density as low as 10 J/L. The propene conversion increased when a manganese oxide based catalyst was used because the ozone produced by the plasma was used as an as an oxidant. A simple model of the plasma-catalyst reactor behaviour showed that more than 90 percent of propene conversion can be expected for an input energy density of 10 J/L and residual ozone concentration less than 100 ppb.

  13. Friedel-Crafts Crosslinked Highly Sulfonated Polyether Ether Ketone (SPEEK) Membranes for a Vanadium/Air Redox Flow Battery.

    Science.gov (United States)

    Merle, Géraldine; Ioana, Filipoi Carmen; Demco, Dan Eugen; Saakes, Michel; Hosseiny, Seyed Schwan

    2013-12-30

    Highly conductive and low vanadium permeable crosslinked sulfonated poly(ether ether ketone) (cSPEEK) membranes were prepared by electrophilic aromatic substitution for a Vanadium/Air Redox Flow Battery (Vanadium/Air-RFB) application. Membranes were synthesized from ethanol solution and crosslinked under different temperatures with 1,4-benzenedimethanol and ZnCl2 via the Friedel-Crafts crosslinking route. The crosslinking mechanism under different temperatures indicated two crosslinking pathways: (a) crosslinking on the sulfonic acid groups; and (b) crosslinking on the backbone. It was observed that membranes crosslinked at a temperature of 150 °C lead to low proton conductive membranes, whereas an increase in crosslinking temperature and time would lead to high proton conductive membranes. High temperature crosslinking also resulted in an increase in anisotropy and water diffusion. Furthermore, the membranes were investigated for a Vanadium/Air Redox Flow Battery application. Membranes crosslinked at 200 °C for 30 min with a molar ratio between 2:1 (mol repeat unit:mol benzenedimethanol) showed a proton conductivity of 27.9 mS/cm and a 100 times lower VO2+ crossover compared to Nafion.

  14. Friedel–Crafts Crosslinked Highly Sulfonated Polyether Ether Ketone (SPEEK Membranes for a Vanadium/Air Redox Flow Battery

    Directory of Open Access Journals (Sweden)

    Géraldine Merle

    2013-12-01

    Full Text Available Highly conductive and low vanadium permeable crosslinked sulfonated poly(ether ether ketone (cSPEEK membranes were prepared by electrophilic aromatic substitution for a Vanadium/Air Redox Flow Battery (Vanadium/Air-RFB application. Membranes were synthesized from ethanol solution and crosslinked under different temperatures with 1,4-benzenedimethanol and ZnCl2 via the Friedel–Crafts crosslinking route. The crosslinking mechanism under different temperatures indicated two crosslinking pathways: (a crosslinking on the sulfonic acid groups; and (b crosslinking on the backbone. It was observed that membranes crosslinked at a temperature of 150 °C lead to low proton conductive membranes, whereas an increase in crosslinking temperature and time would lead to high proton conductive membranes. High temperature crosslinking also resulted in an increase in anisotropy and water diffusion. Furthermore, the membranes were investigated for a Vanadium/Air Redox Flow Battery application. Membranes crosslinked at 200 °C for 30 min with a molar ratio between 2:1 (mol repeat unit:mol benzenedimethanol showed a proton conductivity of 27.9 mS/cm and a 100 times lower VO2+ crossover compared to Nafion.

  15. Friedel–Crafts Crosslinked Highly Sulfonated Polyether Ether Ketone (SPEEK) Membranes for a Vanadium/Air Redox Flow Battery

    Science.gov (United States)

    Merle, Géraldine; Ioana, Filipoi Carmen; Demco, Dan Eugen; Saakes, Michel; Hosseiny, Seyed Schwan

    2014-01-01

    Highly conductive and low vanadium permeable crosslinked sulfonated poly(ether ether ketone) (cSPEEK) membranes were prepared by electrophilic aromatic substitution for a Vanadium/Air Redox Flow Battery (Vanadium/Air-RFB) application. Membranes were synthesized from ethanol solution and crosslinked under different temperatures with 1,4-benzenedimethanol and ZnCl2 via the Friedel–Crafts crosslinking route. The crosslinking mechanism under different temperatures indicated two crosslinking pathways: (a) crosslinking on the sulfonic acid groups; and (b) crosslinking on the backbone. It was observed that membranes crosslinked at a temperature of 150 °C lead to low proton conductive membranes, whereas an increase in crosslinking temperature and time would lead to high proton conductive membranes. High temperature crosslinking also resulted in an increase in anisotropy and water diffusion. Furthermore, the membranes were investigated for a Vanadium/Air Redox Flow Battery application. Membranes crosslinked at 200 °C for 30 min with a molar ratio between 2:1 (mol repeat unit:mol benzenedimethanol) showed a proton conductivity of 27.9 mS/cm and a 100 times lower VO2+ crossover compared to Nafion. PMID:24957118

  16. Flow Control and High-Lift Performance for Flying-Wing Unmanned Combat Air Vehicle Configurations by inserting slots

    Directory of Open Access Journals (Sweden)

    U Ali

    2016-06-01

    Full Text Available The objectives of the present study on Unmanned Combat Air Vehicles (UCAVs are two-fold: first to control the flow by inserting leading-edge and cross-flow slots and analysing the viscous flow development over the outer panels of a flying-wing configuration to maximise the performance of the elevons control surfaces; second to predict high-lift performance particularly the maximum-lift characteristics. This is demonstrated using a variety of inviscid Vortex Lattice Method (VLM and Euler, and viscous CFD Reynolds Averaged Navier-Stokes (RANS methods. The computational results are validated against experiment measured in a wind tunnel. Two flying-wing planforms are considered based around a generic 40˚ edge-aligned configuration. The VLM predicts a linear variation of lift and pitching moment with incidence angle, and substantially under-predicts the induced drag. Results obtained from RANS and Euler agree well with experiment.

  17. Fabry-Perot spectroscopy for kinetic temperature and velocity measurements of a high enthalpy air plasma flow

    Science.gov (United States)

    Zander, Fabian; Löhle, Stefan; Hermann, Tobias; Fulge, Hannes

    2017-08-01

    The atomic translational temperatures and velocities of a low pressure, high enthalpy air plasma are measured using Fabry-Perot spectroscopy. The measurements presented here are the first measurements using this system at this enthalpy level. The sub-picometre resolution of the unique system has allowed accurate translational temperature and velocity measurements of the atomic species in the plasma. The detection system allows the Doppler broadening of multiple atomic nitrogen and oxygen lines to be measured simultaneously. Additionally, having two optical paths, one perpendicular to the flow and one at 45 deg. allows the Doppler shift to be measured. Measurements were taken during three different plasma wind tunnel tests. Mean atomic nitrogen temperatures of 1.08+/- 0.11 × 104 K and atomic oxygen translational temperatures of 1.23+/- 0.12 ×104 K were measured. The thermal non-equilibrium determined verified earlier measurements of the same phenomena, however, the mechanism behind this has not yet been determined. The mean measured flow velocity was 3350+/- 840~m~s-1 and was consistent between the atomic species. The translational temperature and velocity contribute approximately 35% of the local enthalpy of the flow. The direct measurement of these parameters, removing previously required assumptions, increases the fidelity of the flow characterisation significantly. This allows high quality testing to be conducted in this flow field.

  18. Cylindrical air flow reversal barrier

    Energy Technology Data Exchange (ETDEWEB)

    Woznica, C.; Rodziewicz, M.

    1988-06-01

    Describes an innovative design introduced in the ZMP mine in Zory for quick reversal of ventilation air flow. Geologic mining conditions at the 705 m deep horizon, where the barrier was built, are described. According to the design used until now, a reversal system consisted of safety barriers, ventilation air locks, a ventilation bridge and stopping needed in case of a fire when air flow direction must be reversed. Nine air locks and an expensive concrete ventilation bridge were needed and the air locks had to be operated at 8 points of the region to effect reversal. The new design consists of a 2-storey cylindrical barrier which also fulfills the function of a ventilation bridge. It can be manually or remotely operated by a mechanical or pneumatic system. Tests showed that the new barrier permits immediate air flow reversal while retaining 60% of the original air, which is important in the case of fire and methane hazards. It permits improved seam panelling and splitting of pillars and brings an economy of about 40 million zlotys in construction cost. Design and operation of the barrier is illustrated and ventilation air circulation is explained. 7 figs.

  19. Heat transfer measurements on biconics at incidence in hypersonic high enthalpy air and nitrogen flows

    Science.gov (United States)

    Gai, S. L.; Cain, T.; Joe, W. S.; Sandeman, R. J.; Miller, C. G.

    1988-01-01

    Heat transfer rate measurements have been obtained at 0, 5, 15, and 21 deg angles-of-attack for a straight biconic scale model of an aeroassisted orbital vehicle proposed for planetary probe missions. Heat-transfer distributions were measured using palladium thin-film resistance gauges deposited on a glass-ceramic substrate. The windward heat transfer correlations were based on equilibrium flow in the shock layer of the model, although the flow may depart from equilibrium in the flow-field.

  20. Low flow rates and high air throughput: Cross-flow blowers; Niedrige Stroemungsgeschwindigkeiten bei hohem Luftdurchsatz: Querstromventilatoren

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, J. [ebm-papst Landshut GmbH (Germany)

    2006-05-15

    Cross-flow blowers are everywhere, in electric towel driers, heaters, night storage heaters, floor heating systems, and open chimneys. With a diameter of only 30 mm, they are compact and effective. (orig.)

  1. Air-water flow in subsurface systems

    Science.gov (United States)

    Hansen, A.; Mishra, P.

    2013-12-01

    Groundwater traces its roots to tackle challenges of safe and reliable drinking water and food production. When the groundwater level rises, air pressure in the unsaturated Vadose zone increases, forcing air to escape from the ground surface. Abnormally high and low subsurface air pressure can be generated when the groundwater system, rainfall, and sea level fluctuation are favorably combined [Jiao and Li, 2004]. Through this process, contamination in the form of volatile gases may diffuse from the ground surface into residential areas, or possibly move into groundwater from industrial waste sites. It is therefore crucial to understand the combined effects of air-water flow in groundwater system. Here we investigate theoretically and experimentally the effects of air and water flow in groundwater system.

  2. Numerical Analysis on the Influence of Thermal Effects on Oil Flow Characteristic in High-Pressure Air Injection (HPAI Process

    Directory of Open Access Journals (Sweden)

    Hu Jia

    2012-01-01

    Full Text Available In previous laboratory study, we have shown the thermal behavior of Keke Ya light crude oil (Tarim oilfield, branch of CNPC for high-pressure air injection (HPAI application potential study. To clarify the influences of thermal effects on oil production, in this paper, we derived a mathematical model for calculating oil flow rate, which is based on the heat conduction property in porous media from the combustion tube experiment. Based on remarkably limited knowledge consisting of very global balance arguments and disregarding all the details of the mechanisms in the reaction zone, the local governing equations are formulated in a dimensionless form. We use finite difference method to solve this model and address the study by way of qualitative analysis. The time-space dimensionless oil flow rate (qD profiles are established for comprehensive studies on the oil flow rate characteristic affected by thermal effects. It also discusses how these findings will impact HPAI project performances, and several guidelines are suggested.

  3. Automatic air flow control in air conditioning ducts

    Science.gov (United States)

    Obler, H. D.

    1972-01-01

    Device is designed which automatically selects air flow coming from either of two directions and which can be adjusted to desired air volume on either side. Device uses one movable and two fixed scoops which control air flow and air volume.

  4. Flow structure and heat transfer characteristics of an unconfined impinging air jet at high jet Reynolds numbers

    Energy Technology Data Exchange (ETDEWEB)

    Ozmen, Y.; Baydar, E. [Karadeniz Technical University, Department of Mechanical Engineering, Trabzon (Turkey)

    2008-09-15

    The flow and heat transfer characteristics of an unconfined air jet that is impinged normally onto a heated flat plate have been experimentally investigated for high Reynolds numbers ranging from 30,000 to 70,000 and a nozzle-to-plate spacing range of 1-10. The mean and turbulence velocities by using hot-wire anemometry and impingement surface pressures with pressure transducer are measured. Surface temperature measurements are made by means of an infrared thermal imaging technique. The effects of Reynolds number and nozzle-to-plate spacing on the flow structure and heat transfer characteristics are described and compared with similar experiments. It was seen that the locations of the second peaks in Nusselt number distributions slightly vary with Reynolds number and nozzle-to-plate spacing. The peaks in distributions of Nusselt numbers and radial turbulence intensity are compatible for spacings up to 3. The stagnation Nusselt number was correlated for the jet Reynolds number and the nozzle-to-plate spacing as Nu{sub st}{proportional_to}Re {sup 0.69}(H/D){sup 0.019}. (orig.)

  5. Study on Flow Phenomenon inside a Nozzle in Ship Propulsion Equipment Directly Driven by High Pressure Air

    Science.gov (United States)

    Tajiri, Shinsuke; Tsutahara, Michihisa; Ogawa, Kazuhiko; Sakamoto, Masahiko; Tajima, Masakazu; Azuma, Keisuke

    An experimental study was conducted by performing pressure measurements and flow visualization to investigate unsteady flows inside a two-dimensional semi-open-type nozzle in a ship propulsion equipment directly driven by high-pressure gas. We found that the ejected gas phase and water-flow phase are separated clearly, and the interface between these phases behaves like waves. It was clarified by flow visualization with a high-speed motion camera and a circulating water channel that these interfacial waves change their shapes according to the water-flow velocity. The interfacial wavelength increases as a result of increasing water-flow velocity, and the mechanism that produces thrust on the nozzle wall changes. The thrust and flow patterns for intermittent gas ejection according to water-flow velocity were also clarified.

  6. Changes in air flow patterns using surfactants and thickeners during air sparging: bench-scale experiments.

    Science.gov (United States)

    Kim, Juyoung; Kim, Heonki; Annable, Michael D

    2015-01-01

    Air injected into an aquifer during air sparging normally flows upward according to the pressure gradients and buoyancy, and the direction of air flow depends on the natural hydrogeologic setting. In this study, a new method for controlling air flow paths in the saturated zone during air sparging processes is presented. Two hydrodynamic parameters, viscosity and surface tension of the aqueous phase in the aquifer, were altered using appropriate water-soluble reagents distributed before initiating air sparging. Increased viscosity retarded the travel velocity of the air front during air sparging by modifying the viscosity ratio. Using a one-dimensional column packed with water-saturated sand, the velocity of air intrusion into the saturated region under a constant pressure gradient was inversely proportional to the viscosity of the aqueous solution. The air flow direction, and thus the air flux distribution was measured using gaseous flux meters placed at the sand surface during air sparging experiments using both two-, and three-dimensional physical models. Air flow was found to be influenced by the presence of an aqueous patch of high viscosity or suppressed surface tension in the aquifer. Air flow was selective through the low-surface tension (46.5 dyn/cm) region, whereas an aqueous patch of high viscosity (2.77 cP) was as an effective air flow barrier. Formation of a low-surface tension region in the target contaminated zone in the aquifer, before the air sparging process is inaugurated, may induce air flow through the target zone maximizing the contaminant removal efficiency of the injected air. In contrast, a region with high viscosity in the air sparging influence zone may minimize air flow through the region prohibiting the region from de-saturating.

  7. High frequency chest wall oscillation in patients with chronic air-flow obstruction.

    Science.gov (United States)

    Piquet, J; Brochard, L; Isabey, D; de Cremoux, H; Chang, H K; Bignon, J; Harf, A

    1987-12-01

    In order to assess high frequency chest wall oscillation (HFCWO) as a way to assist spontaneous breathing in obstructive lung disease, we studied 12 patients with severe and stable COPD. HFCWO at 5 Hz were applied by means of an inflatable vest. In order to avoid any discomfort, oscillations were applied only during the expiratory phase of the spontaneous breathing cycle. We compared gas exchange and pattern of breathing during control and HFCWO periods, each lasting 15 min. Minute ventilation did not change, but the pattern of breathing was markedly altered during HFCWO: breathing frequency decreased (p less than 0.001) from 18 +/- 6/min during control to 14 +/- 5/min, whereas tidal volume increased (p less than 0.01) from 600 +/- 200 ml during control to 860 +/- 400 ml. Secondary to this change in the pattern of breathing, arterial PO2 increased slightly (p less than 0.01) from 54 +/- 7 mm Hg during control to 57 +/- 8 mm Hg during HFCWO, and arterial PCO2 significantly (p less than 0.01) decreased from 46 +/- 6 mm Hg during control to 43 +/- 7 mm Hg during HFCWO. In addition, duty cycle (Ti/Ttot) decreased (p less than 0.001) from 0.37 +/- 0.03 s during control to 0.29 +/- 0.05 s during HFCWO. Such a decrease in duty cycle suggest that inspiratory muscle work was facilitated under HFCWO. In 8 patients, we obtained the tension-time index (TTdi), or the product of duty cycle and Pdi/Pdimax, and found that this index significantly decreased (p less than 0.05) from 0.06 +/- 0.03 during control to 0.04 +/- 0.02 during HFCWO.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Use of heliox delivered via high-flow nasal cannula to treat an infant with coronavirus-related respiratory infection and severe acute air-flow obstruction.

    Science.gov (United States)

    Morgan, Sherwin E; Vukin, Kirissa; Mosakowski, Steve; Solano, Patti; Stanton, Lolita; Lester, Lucille; Lavani, Romeen; Hall, Jesse B; Tung, Avery

    2014-11-01

    Heliox, a helium-oxygen gas mixture, has been used for many decades to treat obstructive pulmonary disease. The lower density and higher viscosity of heliox relative to nitrogen-oxygen mixtures can significantly reduce airway resistance when an anatomic upper air-flow obstruction is present and gas flow is turbulent. Clinically, heliox can decrease airway resistance in acute asthma in adults and children and in COPD. Heliox may also enhance the bronchodilating effects of β-agonist administration for acute asthma. Respiratory syndromes caused by coronavirus infections in humans range in severity from the common cold to severe acute respiratory syndrome associated with human coronavirus OC43 and other viral strains. In infants, coronavirus infection can cause bronchitis, bronchiolitis, and pneumonia in variable combinations and can produce enough air-flow obstruction to cause respiratory failure. We describe a case of coronavirus OC43 infection in an infant with severe acute respiratory distress treated with heliox inhalation to avoid intubation.

  9. High Bandwidth and Sensitive Air Flow Sensing Based on Resonance Properties of CNT on Fiber Hairs (Postprint)

    Science.gov (United States)

    2017-03-08

    of carbon nanotubes (CNTs) as both the piezoresistive transduction element and the hair pillars and reported that the sensors maintained functionality...A 1-m-long, 5-mm-square inner diameter aluminum alloy plane-wave tube connected on both ends to 8 m of copper pipe was used to expose the hairs to...5-mm-square inner diameter aluminum alloy plane-wave tube connected on both ends to 8 m of copper pipe was used to expose the hairs to air flows at

  10. Air entrainment in open channel flows. Application to spillways

    Energy Technology Data Exchange (ETDEWEB)

    Chanson, H. (Queensland Univ., St. Lucia (Australia))

    1992-01-01

    In open channel flows an important design parameter is the amount of entrained air. The presence of air in high velocity flows or steep chutes increases the bulk of the flow and this is a design parameter that determines the height of chute sidewalls. Furthermore the presence of air within the boundary layer reduces the shear stress between flow layers and hence the shear forces. The resulting increase of fluid motion must be taken in account when designing ski jump and stilling basin downstream of a spillway. Besides the presence of air within high-velocity flows may prevent or reduce cavitation damage. Estimation of the quantity of air entrained along the spillway is required by the design engineer when sitting aerators to artificially introduce more air, or determining whether aerators are required. Recently air entrainment on chutes also been recognized for its contribution to air-water transfer of atmospheric gases such as oxygen and nitrogen. This article describes a general method to compute the flow characteristics of self-aerated flows. Firstly the uniform flow conditions are presented and comparisons will be made between model and prototype results. Then the basic equations for gradually varied aerated flows will be developed, and these results are discussed and compared with experimental data. 28 refs., 8 figs., 3 tabs.

  11. Sensitivity to draught in turbulent air flows

    Energy Technology Data Exchange (ETDEWEB)

    Todde, V.

    1998-09-01

    Even though the ventilation system is designed to supply air flows at constant low velocity and controlled temperature, the resulting air movement in rooms is strongly characterised by random fluctuations. When an air flow is supplied from an inlet, a shear layer forms between the incoming and the standstill air in the room, and large scale vortices develops by coalescence of the vorticity shed at the inlet of the air supply. After a characteristically downstream distance, large scale vortices loose their identity because of the development of cascading eddies and transition to turbulence. The interaction of these vortical structures will rise a complicated three dimensional air movement affected by fluctuations whose frequencies could vary from fractions of Hz to several KHz. The perception and sensitivity to the cooling effect enhanced by these air movements depend on a number of factors interacting with each other: physical properties of the air flow, part and extension of the skin surface exposed to the air flow, exposure duration, global thermal condition, gender and posture of the person. Earlier studies were concerned with the percentage of dissatisfied subjects as a function of air velocity and temperature. Recently, experimental observations have shown that also the fluctuations, the turbulence intensity and the direction of air velocity have an important impact on draught discomfort. Two experimental investigations have been developed to observe the human reaction to horizontal air movements on bared skin surfaces, hands and neck. Attention was concentrated on the effects of relative turbulence intensity of air velocity and exposure duration on perception and sensitivity to the air movement. The air jet flows, adopted for the draught experiment in the neck, were also the object of an experimental study. This experiment was designed to observe the centre-line velocity of an isothermal circular air jet, as a function of the velocity properties at the outlet

  12. The perfect ash-storm: large-scale Pyroclastic Density Current experiments reveal highly mobile, self-fluidising and air-cushioned flow transport regime

    Science.gov (United States)

    Lube, G.; Cronin, S. J.; Breard, E.; Valentine, G.; Bursik, M. I.; Hort, M. K.; Freundt, A.

    2013-12-01

    We report on the first systematic series of large-scale Pyroclastic Density Current (PDC) experiments using the New Zealand PDC Generator, a novel international research facility in Physical Volcanology recently commissioned at Massey University. Repeatable highly energetic and hot PDCs are synthesized by the controlled ';eruption column-collapse' of up to 3500 kg of homogenously aerated Taupo ignimbrite material from a 15 m-elevated hopper onto an instrumented inclined flume. At discharge rates between 250-1300 kg/s and low- to moderate gas injection rates (yielding initial solids concentration of 15-70 vol%) channelized gas-particle mixture flows life-scaled to dense PDCs can be generated. The flow fronts of the currents reach velocities of up to 9.5 m/s over their first 12 m of travel and rapidly develop strong vertical density stratification. The PDCs typically form a highly mobile, surge that also laterally escapes the flume boundaries. Depending on the PDC starting conditions underflows with 1-45 vol% solids concentration are formed, while the upper surge contains <<1 vol.% solids. A characteristic feature of the underflow is the occurrence of 'ignitive' front breakouts, producing jetted lobes that accelerate outward from the flow front, initially forming a lobe-cleft structure, followed by segregation downslope into multiple flow pulses. Depending on initial solids concentration and discharge rate, stratified, dune-bedded and inversely graded bedforms are created whose thicknesses are remarkably uniform along the medial to distal runout path characterising highly mobile flow runout. Along with high-speed video footage we present time-series data of basal arrays of load- and gas-pore pressure transducers to characterise the mobile dense underflows. Data shows that the PDCs are comprised of a turbulent coarse-grained and air-ingesting front with particle-solids concentrations of 1-5 vol%. The front shows a brief phase of negative pore pressure due to the

  13. Air flow exploration of abrasive feed tube

    Science.gov (United States)

    Zhang, Shijin; Li, Xiaohong; Gu, Yilei

    2009-12-01

    An abrasive water-jet cutting process is one in which water pressure is raised to a very high pressure and forced through a very small orifice to form a very thin high speed jet beam. This thin jet beam is then directed through a chamber and then fed into a secondary nozzle, or mixing tube. During this process, a vacuum is generated in the chamber, and garnet abrasives and air are pulled into the chamber, through an abrasive feed tube, and mixes with this high speed stream of water. Because of the restrictions introduced by the abrasive feed tube geometry, a vacuum gradient is generated along the tube. Although this phenomenon has been recognized and utilized as a way to monitor nozzle condition and abrasive flowing conditions, yet, until now, conditions inside the abrasive feed line have not been completely understood. A possible reason is that conditions inside the abrasive feed line are complicated. Not only compressible flow but also multi-phase, multi-component flow has been involved in inside of abrasive feed tube. This paper explored various aspects of the vacuum creation process in both the mixing chamber and the abrasive feed tube. Based on an experimental exploration, an analytical framework is presented to allow theoretical calculations of vacuum conditions in the abrasive feed tube.

  14. Automatic system for air flow control in air-tight chambers of the NPP primary circuit

    Energy Technology Data Exchange (ETDEWEB)

    Bersenev, V.L.; Bagautdinov, Z.S.; Panov, S.Yu.

    1985-01-01

    A system for automatic control of air flows is briefly described which is based on a tensometric flow rate sensor. A sensitive element of the sensor, made of paper-based laminate, under the effect of incoming air flow travels, causing a bending of an elastic element, made of stainless steel. The deformation causes changes in the electric resistance of tensoresistors, the degree of a change being proportional to the air flow rate. A 400 Ohm tensoresistor is used in the sensor. Errors in the flow rate measurement using the tensometric sensor does not exceed +-3% even in the low rate air flow range. The system, tested at the Beloyarsk NPP, has shown a high reliability and accuracy of measurements, which permits to recommend it for the use in technological ventilation of NPPs.

  15. NUMERICAL SIMULATION FOR AIR AND AIR-PM FLOW IN WALL FLOW DIESEL PARTICULATE FILTERS

    Institute of Scientific and Technical Information of China (English)

    Zhao Binjuan; Yuan Shouqi; Seizo Kato; Akira Nishimura

    2005-01-01

    Numerical simulations are performed both for the single airflow and air-PM two-phase flow in wall flow diesel particulate filters (DPF) for the first time. The calculation domain is divided into two regions. In the inlet and outlet flow channels, the simulations are performed for the steady and laminar flow; In the porous filtration walls, the calculation model for flow in porous media is used. The Lagrange two-phase flow model is used to calculate the air-PM flow in DPF, for the dispersed phase (PM), its flow tracks are obtained by the integrating of the Lagrange kinetic equation. The calculated velocity, pressure distribution and PM flow tracks in DPF are obtained, which exhibits the main flow characteristics in wall flow DPF and will be help for the optimal design and performance prediction of wall flow DPF.

  16. Air flow in a collapsing cavity

    CERN Document Server

    Peters, Ivo R; Lohse, Detlef; van der Meer, Devaraj

    2013-01-01

    We experimentally study the airflow in a collapsing cavity created by the impact of a circular disk on a water surface. We measure the air velocity in the collapsing neck in two ways: Directly, by means of employing particle image velocimetry of smoke injected into the cavity and indirectly, by determining the time rate of change of the volume of the cavity at pinch-off and deducing the air flow in the neck under the assumption that the air is incompressible. We compare our experiments to boundary integral simulations and show that close to the moment of pinch-off, compressibility of the air starts to play a crucial role in the behavior of the cavity. Finally, we measure how the air flow rate at pinch-off depends on the Froude number and explain the observed dependence using a theoretical model of the cavity collapse.

  17. Dynamic Flow Management Problems in Air Transportation

    Science.gov (United States)

    Patterson, Sarah Stock

    1997-01-01

    In 1995, over six hundred thousand licensed pilots flew nearly thirty-five million flights into over eighteen thousand U.S. airports, logging more than 519 billion passenger miles. Since demand for air travel has increased by more than 50% in the last decade while capacity has stagnated, congestion is a problem of undeniable practical significance. In this thesis, we will develop optimization techniques that reduce the impact of congestion on the national airspace. We start by determining the optimal release times for flights into the airspace and the optimal speed adjustment while airborne taking into account the capacitated airspace. This is called the Air Traffic Flow Management Problem (TFMP). We address the complexity, showing that it is NP-hard. We build an integer programming formulation that is quite strong as some of the proposed inequalities are facet defining for the convex hull of solutions. For practical problems, the solutions of the LP relaxation of the TFMP are very often integral. In essence, we reduce the problem to efficiently solving large scale linear programming problems. Thus, the computation times are reasonably small for large scale, practical problems involving thousands of flights. Next, we address the problem of determining how to reroute aircraft in the airspace system when faced with dynamically changing weather conditions. This is called the Air Traffic Flow Management Rerouting Problem (TFMRP) We present an integrated mathematical programming approach for the TFMRP, which utilizes several methodologies, in order to minimize delay costs. In order to address the high dimensionality, we present an aggregate model, in which we formulate the TFMRP as a multicommodity, integer, dynamic network flow problem with certain side constraints. Using Lagrangian relaxation, we generate aggregate flows that are decomposed into a collection of flight paths using a randomized rounding heuristic. This collection of paths is used in a packing integer

  18. Minimum detectable air velocity by thermal flow sensors.

    Science.gov (United States)

    Issa, Safir; Lang, Walter

    2013-08-19

    Miniaturized thermal flow sensors have opened the doors for a large variety of new applications due to their small size, high sensitivity and low power consumption. Theoretically, very small detection limits of air velocity of some micrometers per second are achievable. However, the superimposed free convection is the main obstacle which prevents reaching these expected limits. Furthermore, experimental investigations are an additional challenge since it is difficult to generate very low flows. In this paper, we introduce a physical method, capable of generating very low flow values in the mixed convection region. Additionally, we present the sensor characteristic curves at the zero flow case and in the mixed convection region. Results show that the estimated minimum detectable air velocity by the presented method is 0.8 mm/s. The equivalent air velocity to the noise level of the sensor at the zero flow case is about 0.13 mm/s.

  19. 40 CFR 89.414 - Air flow measurement specifications.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Air flow measurement specifications... Emission Test Procedures § 89.414 Air flow measurement specifications. (a) The air flow measurement method used must have a range large enough to accurately measure the air flow over the engine operating...

  20. 40 CFR 91.416 - Intake air flow measurement specifications.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Intake air flow measurement... Procedures § 91.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure the air flow over the...

  1. The effect of additional resistance of air flow on the functioning parameters of the highly qualified rowers' outer respiration

    Directory of Open Access Journals (Sweden)

    Grechuha S.V.

    2010-03-01

    Full Text Available Influence of additional resistance the current of air is rotined on the feature of functioning of the system of the external breathing of sportsmen. In experiment 12 sportsmen took part 17-25 years. All sportsmen are candidates or sport masters. Experience of employments of sportsmen made 4-12 years. Tests were conducted in a preparatory period of annual cycle of training. The dynamics of changes speed of current of air is presented, ventilations of lights at peace and at the dosed physical loading. More effective for development of functional possibilities of respiratory muscles for sportsmen it is possible to count application of additional resistance on exhalation.

  2. Air Flow and Dispersion Section

    Energy Technology Data Exchange (ETDEWEB)

    Slinn, W. G.N.; Nicola, P. W.; Powell, D. C.; Davis, W. E.

    1976-03-01

    There are eight papers in this section. Some of the fundamentals of atmospheric dispersion of pollutants are examined with theoretical analyses as well as detailed experimental investigations. Emphasis has been placed on analyzing and summarizing previous experimental dispersion data with more realistic and fundamentally sound approaches to plume behavior. The goal is to finalize improved short-range dispersion models from existing data, removing inconsistencies and inadequacies in presently applied assessment models. Dispersion and transport efforts in the future should aim toward evaluating plume behavior on meso and regional scales. The complex features of flow and dispersion through storms, and in the vicinity of significant terrain characteristics influencing local to regional circulations must receive future emphasis. (auth)

  3. The air-liquid flow in a microfluidic airway tree.

    Science.gov (United States)

    Song, Yu; Baudoin, Michael; Manneville, Paul; Baroud, Charles N

    2011-09-01

    Microfluidic techniques are employed to investigate air-liquid flows in the lung. A network of microchannels with five generations is made and used as a simplified model of a section of the pulmonary airway tree. Liquid plugs are injected into the network and pushed by a flow of air; they divide at every bifurcation until they reach the exits of the network. A resistance, associated with the presence of one plug in a given generation, is defined to establish a linear relation between the driving pressure and the total flow rate in the network. Based on this resistance, good predictions are obtained for the flow of two successive plugs in different generations. The total flow rate of a two-plug flow is found to depend not only on the driving pressure and lengths of the plugs, but also the initial distance between them. Furthermore, long range interactions between daughters of a dividing plug are observed and discussed, particularly when the plugs are flowing through the bifurcations. These interactions lead to different flow patterns for different forcing conditions: the flow develops symmetrically when subjected to constant pressure or high flow rate forcing, while a low flow rate driving yields an asymmetric flow.

  4. Visualization of air flow using infrared thermography

    Science.gov (United States)

    Narayanan, V.; Page, R. H.; Seyed-Yagoobi, J.

    2003-02-01

    A technique to visualize airflow using IR thermography is developed. A trace quantity of sulfur hexafluoride (SF6) gas is injected into the flow field to detect intensity patterns using a scanning IR thermography system with a single 8-13 µm bandwidth detector. Equations that relate the intensity patterns to volume-averaged temperature and SF6 mass concentration are presented. The visualization technique involves using a background surface at a known temperature different from that of the flow and image subtraction. The technique is demonstrated on free, impinging, and reattachment subsonic air jets, and is shown to be an effective means of visualizing flows at both elevated and ambient temperatures.

  5. Characteristics of Air Flow through Windows

    DEFF Research Database (Denmark)

    Heiselberg, Per; Dam, Henrik; Sørensen, Lars C.

    This paper describes the first results of a series of laboratory investigations that is performed to characterise three different window types. The results show the air flow conditions for different ventilation strategies and temperature differences. For one of the windows values of the discharge...

  6. Air flow through smooth and rough cracks

    Energy Technology Data Exchange (ETDEWEB)

    Kula, H.-G.; Sharples, S. [Sheffield Univ. (United Kingdom). Dept. of Building Science

    1994-12-31

    A series of laboratory experiments are described which investigated the effect of surface roughness on the air flow characteristics of simple, straight-through, no-bend cracks with smooth and rough internal surfaces. The crack thicknesses used in the study were 1.0, 1.5 and 2.0mm. The crack lengths, in the direction of flow, were 50.8mm and 76.2mm. For the rough cracks the roughness was simulated with two different grades of commercially available energy-cloth (grade 60 and 100). The experimental results were satisfactorily fitted to a quadratic relationship between {Delta}p and Q of the form {Delta}p = AQ + BQ{sup 2} for both the smooth and rough crack data. The effect of roughness on the reduction of air flowing through a crack is also discussed. (author)

  7. Review of air flow measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, Jennifer

    2002-12-01

    Airflow measurement techniques are necessary to determine the most basic of indoor air quality questions: ''Is there enough fresh air to provide a healthy environment for the occupants of the building?'' This paper outlines airflow measurement techniques, but it does not make recommendations for techniques that should be used. The airflows that will be discussed are those within a room or zone, those between rooms or zones, such as through doorways (open or closed) or passive vents, those between the building and outdoors, and those through mechanical air distribution systems. Techniques that are highlighted include particle streak velocimetry, hot wire anemometry, fan pressurization (measuring flow at a given pressure), tracer gas, acoustic methods for leak size determination, the Delta Q test to determine duct leakage flows, and flow hood measurements. Because tracer gas techniques are widely used to measure airflow, this topic is broken down into sections as follows: decay, pulse injection, constant injection, constant concentration, passive sampling, and single and multiple gas measurements for multiple zones.

  8. A survey of air flow models for multizone structures

    Energy Technology Data Exchange (ETDEWEB)

    Feustel, H.E.; Dieris, J.

    1991-03-01

    Air flow models are used to simulate the rates of incoming and outgoing air flows for a building with known leakage under given weather and shielding conditions. Additional information about the flow paths and air-mass flows inside the building can only by using multizone air flow models. In order to obtain more information on multizone air flow models, a literature review was performed in 1984. A second literature review and a questionnaire survey performed in 1989, revealed the existence of 50 multizone air flow models, all developed since 1966, two of which are still under development. All these programs use similar flow equations for crack flow but differ in the versatility to describe the full range of flow phenomena and the algorithm provided for solving the set of nonlinear equations. This literature review was found that newer models are able to describe and simulate the ventilation systems and interrelation of mechanical and natural ventilation. 27 refs., 2 figs., 1 tab.

  9. 30 CFR 57.22213 - Air flow (III mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air flow (III mines). 57.22213 Section 57.22213... Methane in Metal and Nonmetal Mines Ventilation § 57.22213 Air flow (III mines). The quantity of air... longwall and continuous miner sections. The quantity of air across each face at a work place shall be...

  10. 40 CFR 90.416 - Intake air flow measurement specifications.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Intake air flow measurement... Gaseous Exhaust Test Procedures § 90.416 Intake air flow measurement specifications. (a) If used, the engine intake air flow measurement method used must have a range large enough to accurately measure...

  11. 40 CFR 1065.225 - Intake-air flow meter.

    Science.gov (United States)

    2010-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Flow-Related Measurements § 1065.225 Intake-air... § 1065.205. This may include a laminar flow element, an ultrasonic flow meter, a subsonic venturi, a... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Intake-air flow meter....

  12. Analysis of Air Flow Field in Air Conditioning System and Compartments of High-Speed Trains%高速列车空调系统及车内流场分析

    Institute of Scientific and Technical Information of China (English)

    刘杰; 李人宪; 陈琳; 李树典

    2012-01-01

    In order to test the rationality of the air-conditioning system design of high-speed trains, an entire geometry model for compartment and air-conditioning system of high-speed trains was built considering the characteristics of negative pressure at fresh-air inlet, complicated air-conditioning pipes and good airtightness. The airflow field in the entire geometry was simulated by solving the governing differential functions of computational fluid dynamics ( CFD) using the finite volume method. The distributions of velocity field, temperature field, humidity field, and CO2 concentration in the chamber were obtained, and the thermal comfort was evaluated by flow field indexes and comfort indexes. The results show that when a train is running at 350 km/h in summer, the temperature distribution is uniform in compartments; the average value of CO2 concentration is 0.07% to meet the demand for comfort (less than 0. 15% ); because of the high wind velocity, effective temperature difference at aisle is -4. 5 °C , which is 2. 8 °C below the standard value of the thermal comfort index; and an appropriate air supply and recycle mode is crucial to obtain uniform flow field and good thermal comfort.%为检验高速列车空调系统设计的合理性,针对高速列车新风入口负压大、空调管路系统复杂、密封性好的特点,建立了车厢内部与空调系统的整体模型.用有限体积法求解计算流体力学的控制微分方程,对整体流场进行数值模拟,得到了风速、温度、湿度和CO2体积浓度在客室内的分布,并用流场指标和热舒适性指标对客室内的热舒适性进行了评价.结果表明:夏季列车以350 km/h的速度行驶时,车厢内温度场分布比较均匀,CO2体积浓度平均值为0.07%,满足不大于0.15%的舒适性要求;过道处风速高,导致有效温度差最大为-4.5℃,低于舒适指标标准值2.8℃;送、回风方式是保证流场参数均匀分布及热舒适性的关键.

  13. Optimization of recirculating laminar air flow in operating room air conditioning systems

    Directory of Open Access Journals (Sweden)

    Enver Yalcin

    2016-04-01

    Full Text Available The laminar flow air-conditioning system with 100% fresh air is used in almost all operating rooms without discrimination in Turkey. The laminar flow device which is working with 100% fresh air should be absolutely used in Type 1A operating rooms. However, there is not mandatory to use of 100% fresh air for Type 1B defined as places performed simpler operation. Compared with recirculating laminar flow, energy needs of the laminar flow with 100 % fresh air has been emerged about 40% more than re-circulated air flow. Therefore, when a recirculating laminar flow device is operated instead of laminar flow system with 100% fresh air in the Type 1B operating room, annual energy consumption will be reduced. In this study, in an operating room with recirculating laminar flow, optimal conditions have been investigated in order to obtain laminar flow form by analyzing velocity distributions at various supply velocities by using computational fluid dynamics method (CFD.

  14. Air flow management in raised floor data centers

    CERN Document Server

    Arghode, Vaibhav K

    2016-01-01

    The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers.

  15. High Efficiency Room Air Conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, Pradeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

  16. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    Energy Technology Data Exchange (ETDEWEB)

    Skwarczynski, M.A. [Faculty of Environmental Engineering, Institute of Environmental Protection Engineering, Department of Indoor Environment Engineering, Lublin University of Technology, Lublin (Poland); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Melikov, A.K.; Lyubenova, V. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Kaczmarczyk, J. [Faculty of Energy and Environmental Engineering, Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Gliwice (Poland)

    2010-10-15

    The effect of facially applied air movement on perceived air quality (PAQ) at high humidity was studied. Thirty subjects (21 males and 9 females) participated in three, 3-h experiments performed in a climate chamber. The experimental conditions covered three combinations of relative humidity and local air velocity under a constant air temperature of 26 C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front toward the upper part of the body (upper chest, head). The subjects could control the flow rate (velocity) of the supplied air in the vicinity of their bodies. The results indicate an airflow with elevated velocity applied to the face significantly improves the acceptability of the air quality at the room air temperature of 26 C and relative humidity of 70%. (author)

  17. Air Flow and Gassing Potential in Micro-injection Moulding

    DEFF Research Database (Denmark)

    Griffithsa, C.A.; Dimova, S.S.; Scholz, S.

    2011-01-01

    Process monitoring of micro injection moulding (μ-IM) is of crucial importance in understanding the effects of different parameter settings on the process, especially on its performance and consistency in regards to parts’ quality. Quality factors related to mould cavity air evacuation can provide...... valuable information about the process dynamics and also about the filling of a cavity by a polymer melt. In this paper, a novel experimental set-up is proposed to monitor maximum air flow and air flow work as an integral of the air flow over time by employing a MEMS gas sensor mounted inside the mould....... The influence of four μIM parameters, melt temperature, mould temperature, injection speed, and resistance to air evacuation, on two air flow-related output parameters is investigated by carrying out a design of experiment study. The results provide empirical evidence about the effects of process parameters...

  18. Cavity air flow behavior during filling in microinjection molding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2011-01-01

    Process monitoring of microinjection molding (μ-IM) is of crucial importance in understanding the effects of different parameter settings on the process, especially on its performance and consistency with regard to parts' quality. Quality factors related to mold cavity air evacuation can provide...... valuable information about the process dynamics and also about the filling of a cavity by a polymer melt. In this paper, a novel experimental setup is proposed to monitor maximum air flow and air flow work as an integral of the air flow over time by employing a microelectromechanical system gas sensor...... mounted inside the mold. The influence of four μIM parameters, melt temperature, mold temperature, injection speed, and resistance to air evacuation, on two air flow-related output parameters is investigated by carrying out a design of experiment study. The results provide empirical evidences about...

  19. Specific Properties of Air Flow Field Within the Grinding Zone

    Institute of Scientific and Technical Information of China (English)

    ZHENG Junyi; JIANG Zhengfeng; ZHAO Liang

    2006-01-01

    Air barrier of grinding means a boundary layer of air existing at the circumference of the rotating wheel, which hinders coolant from entry. This paper makes a research on air flow field of the grinding zone through experiments and numerical simulations, focusing on acquainting with the specific properties of the air flow field. Finite volume method is applied to analyze air flow field within grinding wheel in the course of numerical calculations. The test devices such as Hot-wire anemometer and Betz manometer are used during the experiments of testing the pressure and velocity within grinding zone. Results of experiments agree by and large with numerical results of calculations. The conclusions obtained in this paper, the distribution of wall pressure and the distribution of air flow velocity, are important and useful to navigate the delivery of coolant into the grinding zone. In conclusion, some recommendations are made for further study and practical applications in such field.

  20. Air Flow Measurements During Medium-Voltage Load Current Interruptions

    OpenAIRE

    Aanensen, Nina Sasaki; Runde, Magne

    2015-01-01

    Air has been considered a good alternative to SF6 as arc quenching medium for load break switchgear at medium voltage ratings. In this work, the air flow characteristics and influence from the electric arc have been studied for typical currents and over-pressures. The cooling air velocity is typically in the range 150 - 200 m/s and thus well below supersonic speed. The arc and the surrounding hot air severely affect the air flow pattern by causing clogging in the contact and nozzle region.

  1. Air conditioning system and component therefore distributing air flow from opposite directions

    Science.gov (United States)

    Obler, H. D.; Bauer, H. B. (Inventor)

    1974-01-01

    The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.

  2. A TWO-PHASE FLOW MODEL FOR SIMULATING AIR ENTRAPMENT DURING MOLD FILLING OF HIGH PRESSURE DIE CASTING PROCESS%应用两相流模型模拟压铸充型过程的卷气现象

    Institute of Scientific and Technical Information of China (English)

    李帅君; 熊守美; Mei Li; John Allison

    2009-01-01

    通过对压铸充型过程中卷气缺陷形成机理的分析,认为型腔中空气的流动以及与金属液之间的相互作用是形成卷气现象的主要原因.为了考虑型腔中空气的流动,采用了一种不可压缩两相流数学模型来模拟压铸充型过程的卷气现象.通过计算流体力学中的两个基准算例,较为全面地验证了该模型的准确性和可靠性.在此基础上,设计了专门针对压铸充型过程的高速水模拟实验,通过对可视化实验结果与两相流模拟结果的比较,证实二者吻合较好,说明了该模型能够较好地模拟液体的充填行为和卷入其中的气泡.%The most common defect found in high pressure die casting (HPDC) process is the gas porosity which significantly affects the mechanical properties of the final components. The generation of gas porosity is known mainly due to the air entrapment in the liquid metal during the mold filling stage. Knowing the trapped-air location and amount could allow for a more accurate and objective analysis of casting quality. In the past few decades, extensive efforts have been made to develop simulation codes of casting flow. Most of these codes solve the velocity, pressure and fluid fraction only in the liquid phase with the assumption that the effect of air in the die cavity is negligible. As a matter of fact, the air in the die cavity has significant influence on the filling pattern of the molten metal and the gas porosity distribution of the die casts. Recently, following the development of computational fluid dynamics (CFD), two-phase flow models have drawn continuous attention in the numerical simulation of casting processes, but there are still few models and further studies are needed. In this study, the mechanism of the formation of air entrapment defects in the HPDC process was discussed and it turned out that the air flow in the die cavity as well as the interaction between air and liquid metal resulted in the final air

  3. Flow Field Characteristics of the Rotor Cage in Turbo Air Classifiers

    Institute of Scientific and Technical Information of China (English)

    GUO Lijie; LIU Jiaxiang; LIU Shengzhao

    2009-01-01

    The turbo air classifier is widely used powder classification equipment in a variety of fields. The flow field characteristics of the turbo air classifier are important basis for the improvement of the turbo air classifier's structural design. The flow field characteristics of the rotor cage in turbo air classifiers were investigated under different operating conditions by laser Doppler velocimeter(LDV), and a measure diminishing the axial velocity is proposed. The investigation results show that the tangential velocity of the air flow inside the rotor cage is different from the rotary speed of the rotor cage on the same measurement point due to the influences of both the negative pressure at the exit and the rotation of the rotor cage. The tangential velocity of the air flow likewise decreases as the radius decreases in the case of the rotor cage's low rotary speed. In contrast, the tangential velocity of the air flow increases as the radius decreases in the case of the rotor cage's high rotary speed. Meanwhile, the vortex inside the rotor cage is found to occur near the pressure side of the blade when the rotor cage's rotary speed is less than the tangential velocity of air flow. On the contrary, the vortex is found to occur near the blade suction side once the rotor cage's rotary speed is higher than the tangential velocity of air flow. Inside the rotor cage, the axial velocity could not be disregarded and is largely determined by the distances between the measurement point and the exit.

  4. High Altitude Clear Air Turbulence Project

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Air Force Flight Dynamics Laboratory conducted the High Altitude Clear Air Turbulence Project in the mid 1960s with the intention of better understanding air...

  5. Modeling of Air Temperature for Heat Exchange due to Vertical Turbulence and Horizontal Air Flow

    Institute of Scientific and Technical Information of China (English)

    ZHANG Lei; MENG Qing-lin

    2009-01-01

    In order to calculate the air temperature of the near surface layer in urban environment,the Sur-face layer air was divided into several layers in the vertical direction,and some energy bakmce equations were de-veloped for each air layer,in which the heat exchange due to vertical turbulence and horizontal air flow was tak-en into account.Then,the vertical temperature distribution of the surface layer air was obtained through the coupled calculation using the energy balance equations of underlying surfaces and building walls.Moreover,the measured air temperatures in a small area (with a horizontal scale of less than 500 m) and a large area (with ahorizontal scale of more than 1000 m) in Guangzhou in summer were used to validate the proposed model.The calculated results agree well with the measured ones,with a maximum relative error of 4.18%.It is thus con-cluded that the proposed model is a high-accuracy method to theoretically analyze the urban heat island and the thermal environment.

  6. High Energy Efficiency Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Edward McCullough; Patrick Dhooge; Jonathan Nimitz

    2003-12-31

    This project determined the performance of a new high efficiency refrigerant, Ikon B, in a residential air conditioner designed to use R-22. The refrigerant R-22, used in residential and small commercial air conditioners, is being phased out of production in developed countries beginning this year because of concerns regarding its ozone depletion potential. Although a replacement refrigerant, R-410A, is available, it operates at much higher pressure than R-22 and requires new equipment. R-22 air conditioners will continue to be in use for many years to come. Air conditioning is a large part of expensive summer peak power use in many parts of the U.S. Previous testing and computer simulations of Ikon B indicated that it would have 20 - 25% higher coefficient of performance (COP, the amount of cooling obtained per energy used) than R-22 in an air-cooled air conditioner. In this project, a typical new R-22 residential air conditioner was obtained, installed in a large environmental chamber, instrumented, and run both with its original charge of R-22 and then with Ikon B. In the environmental chamber, controlled temperature and humidity could be maintained to obtain repeatable and comparable energy use results. Tests with Ikon B included runs with and without a power controller, and an extended run for several months with subsequent analyses to check compatibility of Ikon B with the air conditioner materials and lubricant. Baseline energy use of the air conditioner with its original R-22 charge was measured at 90 deg F and 100 deg F. After changeover to Ikon B and a larger expansion orifice, energy use was measured at 90 deg F and 100 deg F. Ikon B proved to have about 19% higher COP at 90 deg F and about 26% higher COP at 100 deg F versus R-22. Ikon B had about 20% lower cooling capacity at 90 deg F and about 17% lower cooling capacity at 100 deg F versus R-22 in this system. All results over multiple runs were within 1% relative standard deviation (RSD). All of these

  7. Calculation of flow distribution in air reverse circulation bit interior fluid field by simplifying air flow model

    Institute of Scientific and Technical Information of China (English)

    Shuqing HAO; Hongwei HUANG; Kun YIN

    2007-01-01

    By simplifying the characters in the air reverse circulation bit interior fluid field, the authors used air dynamics and fluid mechanics to calculate the air distribution in the bit and obtained an equation of flow distribution with a unique resolution. This study will provide help for making certain the bit parameters of the bit structure effectively and study the air reverse circulation bit interior fluid field character deeply.

  8. Polymer electrolyte fuel cells: flow field for efficient air operation

    Energy Technology Data Exchange (ETDEWEB)

    Buechi, F.N.; Tsukada, A.; Haas, O.; Scherer, G.G. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    A new flow field was designed for a polymer electrolyte fuel cell stack with an active area of 200 cm{sup 2} for operation at low air stoichiometry and low air over pressure. Optimum of gas flow and channel dimensions were calculated based on the required pressure drop in the fluid. Single cells and a bi-cell stack with the new flow field show an improved current/voltage characteristic when operated at low air stoichiometries as compared to that of the previous non optimized design. (author) 4 figs., 3 refs.

  9. Numerical Analysis for the Air Flow of Cross Flow Fan

    Science.gov (United States)

    Sakai, Hirokazu; Tokushge, Satoshi; Ishikawa, Masatoshi; Ishihara, Takuya

    There are many factors for designing the cross flow fan. Therefore, the performance of cross flow fan is not clear yet. We can analyze the transient flow of a cross flow fan using sliding mesh approach. One of the tasks using Computational Fluid Dynamics (CFD) is a way of modeling for analysis heat exchangers with cross flow fan. These tasks are very important for design. The paper has a modeling of heat exchangers and meshing the fan blades. The next tasks, we focus the ability of cross flow fan when we change the geometry of fan blades.

  10. Heating control strategy in fresh air processor matched with variable refrigerant flow air conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Tu Qiu, E-mail: tuqiuky@163.co [Guangzhou Institute of Energy Conversion, Chinese Academy of Science, Guangzhou 510640 (China) and Key Laboratory of Renewable Energy and Gas Hydrate, Chinese Academy of Science, Guangzhou 510640 (China); Mao Shoubo; Feng Yuhai; Guo Defang [Haier Air-Conditioning Electronic Co. Ltd., Qingdao 266510 (China)

    2011-07-15

    Highlights: {yields} A set of fresh air processor matched with VRF AC has been designed. {yields} The heating control model of variable condensation temperature target has been presented {yields} The control strategy can realize reliable running, high control accuracy and energy-saving. {yields} The control model is universal for fresh air processors with different capacities. -- Abstract: The fresh air processor (FAP), matched with the variable refrigerant flow air conditioning system (VRF AC), has been developed. Two control methods were adopted to control the system running and air outlet temperature, contrastively. The first method is that the running frequency in heating mode is adjusted in terms of the ordinary control method of VRF, i.e., constant condensation temperature. The experiment demonstrates the control method is not feasible. For nominal heating under different static pressure and defrosting under 200 Pa static pressure, the system fluctuates frequently. And for high temperature heating, the air outlet temperature far exceeds the target temperature. Furthermore, the control model of variable condensation temperature target has been presented, and the heat transfer correction factor is introduced into the control model. And the control parameters in the model are determined by experiment. The control model is universal for FAPs with different capacities by identifying and choosing the heat transfer correction factor in the control program. For low temperature heating, the method of switching rotation speed of the motor can be adopted to enhance air outlet temperature to 22 {sup o}C. The control strategy can provide guide for the design and application of FAP.

  11. Analysis of Air Flow in the Ventilated Insulating Air Layer of the External Wall

    Science.gov (United States)

    Katunská, Jana; Bullová, Iveta; Špaková, Miroslava

    2016-12-01

    The paper deals with problems of impact of air flow in ventilated insulating air layer of the external wall on behaviour of thermal-technical parameters of the proposed external structure (according principles of STN 73 0549, which is not valid now), by comparing them in the calculation according to the valid STN standards, where air flow in the ventilated air layer is not taken into account, as well as by comparing them with behavior of thermal-technical parameters in the proposal of sandwich external wall with the contact heat insulation system without air cavity.

  12. On the use of various oscillatory air flow fields for characterization of biomimetic hair flow sensors

    NARCIS (Netherlands)

    Droogendijk, H.; Dagamseh, A.M.K.; Yntema, D.R.; Sanders, R.G.P.; Krijnen, G.J.M.

    2011-01-01

    To determine the characteristics of flow sensors, a suitable source for flow generation is required. We discuss three different sources for oscillating air flow, by considering their acoustic impedance, frequency range, velocity and ability to distinguish between flow and pressure. We discuss the im

  13. On the Use of Various Oscillatory Air Flow Fields for Characterization of Biomimetic Hair Flow Sensors

    NARCIS (Netherlands)

    Droogendijk, H.; Dagamseh, A.M.K.; Yntema, D.R.; Sanders, R.G.P.; Krijnen, G.J.M.

    2011-01-01

    To determine the characteristics of flow sensors, a suitable source for flow generation is required. We discuss three different sources for oscillating air flow, by considering their acoustic impedance, frequency range, velocity and ability to distinguish between flow and pressure. We discuss the im

  14. Ozone concentrations in air flowing into New York State

    Science.gov (United States)

    Aleksic, Nenad; Kent, John; Walcek, Chris

    2016-09-01

    Ozone (O3) concentrations measured at Pinnacle State Park (PSPNY), very close to the southern border of New York State, are used to estimate concentrations in air flowing into New York. On 20% of the ozone season (April-September) afternoons from 2004 to 2015, mid-afternoon 500-m back trajectories calculated from PSPNY cross New York border from the south and spend less than three hours in New York State, in this area of negligible local pollution emissions. One-hour (2p.m.-3p.m.) O3 concentrations during these inflowing conditions were 46 ± 13 ppb, and ranged from a minimum of 15 ppb to a maximum of 84 ppb. On average during 2004-2015, each year experienced 11.8 days with inflowing 1-hr O3 concentrations exceeding 50 ppb, 4.3 days with O3 > 60 ppb, and 1.5 days had O3 > 70 ppb. During the same period, 8-hr average concentrations (10a.m. to 6p.m.) exceeded 50 ppb on 10.0 days per season, while 3.9 days exceeded 60 ppb, and 70 ppb was exceeded 1.2 days per season. Two afternoons of minimal in-state emission influences with high ozone concentrations were analyzed in more detail. Synoptic and back trajectory analysis, including comparison with upwind ozone concentrations, indicated that the two periods were characterized as photo-chemically aged air containing high inflowing O3 concentrations most likely heavily influenced by pollution emissions from states upwind of New York including Pennsylvania, Tennessee, West Virginia, and Ohio. These results suggest that New York state-level attempts to comply with National Ambient Air Quality Standards by regulating in-state O3 precursor NOx and organic emissions would be very difficult, since air frequently enters New York State very close to or in excess of Federal Air Quality Standards.

  15. Numerical Prediction of Buoyant Air Flow in Livestock Buildings

    DEFF Research Database (Denmark)

    Svidt, Kjeld

    not include the effect of room geometry, obstacles or heat sources. This paper describes the use of Computational Fluid Dynamics to predict air flow patterns and temperature distribution in a ventilated space. Good agreement is found when results of numerical predictions are compared with experimental data.......In modern livestock buildings air distribution and air quality are important parameters to animal welfare and to the health of full-tithe employees in animal production. Traditional methods for calculating air distribution in farm buildings are mainly based on formulas for air jets which do...

  16. Droplet detachment by air flow for microstructured superhydrophobic surfaces.

    Science.gov (United States)

    Hao, Pengfei; Lv, Cunjing; Yao, Zhaohui

    2013-04-30

    Quantitative correlation between critical air velocity and roughness of microstructured surface has still not been established systematically until the present; the dynamics of water droplet detachment by air flow from micropillar-like superhydrophobic surfaces is investigated by combining experiments and simulation comparisons. Experimental evidence demonstrates that the onset of water droplet detachment from horizontal micropillar-like superhydrophobic surfaces under air flow always starts with detachment of the rear contact lines of the droplets from the pillar tops, which exhibits a similar dynamic mechanism for water droplet motion under a gravity field. On the basis of theoretical analysis and numerical simulation, an explicit analytical model is proposed for investigating the detaching mechanism, in which the critical air velocity can be fully determined by several intrinsic parameters: water-solid interface area fraction, droplet volume, and Young's contact angle. This model gives predictions of the critical detachment velocity of air flow that agree well with the experimental measurements.

  17. Experimental study of humid air reverse diffusion combustion in a turbulent flow field

    Institute of Scientific and Technical Information of China (English)

    GE Bing; ZANG Shusheng; GU Xin

    2007-01-01

    Experiments were performed to investigate the differences between the propane/air turbulent diffusion reactive flows past bluff-body and the propane/humid air turbulent diffusion reactive flows in the same conditions.The velocity distributions of the non-humid reactive flow fields and the humid reactive flow fields were measured by particle image velocimetry (PIV) techniques.The temperature fields were measured by high temperature thermocouples,and NOx distributions were obtained by using gas detection instruments.The results show that although humid air reactive flow fields are similar to non-humid flow fields in general,there are some differences in the humid air combustion flow field comparing with the non-humid combustion flow field:the center of the reversed-flow region goes forward;the dimension of the reversed-flow region is smaller;the peak temperature and NOx formation are reduced.It is suggested that humid air combustion is helpful to shorten the axial length of combustors,and reduce the formation of pollutants.

  18. Effect of Air Flow on Tubular Solar Still Efficiency

    Directory of Open Access Journals (Sweden)

    Arunkumar Thirugnanasambantham

    2013-04-01

    Full Text Available An experimental work was reported to estimate the increase in distillate yield for a compound parabolic concentrator-concentric tubular solar still (CPC-CTSS. The CPC dramatically increases the heating of the saline water. A novel idea was proposed to study the characteristic features of CPC for desalination to produce a large quantity of distillate yield. A rectangular basin of dimension 2 m × 0.025 m × 0.02 m was fabricated of copper and was placed at the focus of the CPC. This basin is covered by two cylindrical glass tubes of length 2 m with two different diameters of 0.02 m and 0.03 m. The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively.Findings:The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s.Conclusions:On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively.

  19. The flow feature of transverse hydrogen jet in presence of micro air jets in supersonic flow

    Science.gov (United States)

    Barzegar Gerdroodbary, M.; Amini, Younes; Ganji, D. D.; Takam, ​M. Rahimi

    2017-03-01

    Scramjet is found to be the efficient method for the space shuttle. In this paper, numerical simulation is performed to investigate the fundamental flow physics of the interaction between an array of fuel jets and multi air jets in a supersonic transverse flow. Hydrogen as a fuel is released with a global equivalence ratio of 0.5 in presence of micro air jets on a flat plate into a Mach 4 crossflow. The fuel and air are injected through streamwise-aligned flush circular portholes. The hydrogen is injected through 4 holes with 7dj space when the air is injected in the interval of the hydrogen jets. The numerical simulation is performed by using the Reynolds-averaged Navier-Stokes equations with Menter's Shear Stress Transport (SST) turbulence model. Both the number of air jets and jet-to-freestream total pressure ratio are varied in a parametric study. The interaction of the fuel and air jet in the supersonic flow present extremely complex feature of fuel and air jet. The results present various flow features depending upon the number and mass flow rate of micro air jets. These flow features were found to have significant effects on the penetration of hydrogen jets. A variation of the number of air jets, along with the jet-to-freestream total pressure ratio, induced a variety of flow structure in the downstream of the fuel jets.

  20. Flow development through HP & LP turbines, Part II: Effects of the hub endwall secondary sealing air flow on the turbine's mainstream flow

    Science.gov (United States)

    Hu, Jialin; Du, Qiang; Liu, Jun; Wang, Pei; Liu, Guang; Liu, Hongrui; Du, Meimei

    2017-08-01

    Although many literatures have been focused on the underneath flow and loss mechanism, very few experiments and simulations have been done under the engines' representative working conditions or considering the real cavity structure as a whole. This paper aims at realizing the goal of design of efficient turbine and scrutinizing the velocity distribution in the vicinity of the rim seal. With the aid of numerical method, a numerical model describing the flow pattern both in the purge flow spot and within the mainstream flow path is established, fluid migration and its accompanied flow mechanism within the realistic cavity structure (with rim seal structure and considering mainstream & secondary air flow's interaction) is used to evaluate both the flow pattern and the underneath flow mechanism within the inward rotating cavity. Meanwhile, the underneath flow and loss mechanism are also studied in the current paper. The computational results show that the sealing air flow's ingestion and ejection are highly interwound with each other in both upstream and downstream flow of the rim seal. Both the down-stream blades' potential effects as well as the upstream blades' wake trajectory can bring about the ingestion of the hot gas flow within the cavity, abrupt increase of the static pressure is believed to be the main reason. Also, the results indicate that sealing air flow ejected through the rear cavity will cause unexpected loss near the outlet section of the blades in the downstream of the HP rotor passages.

  1. CDF modeling of flow and transport processes in the reactor core of a modular high temperature reactor during an air ingress accident; CFD-Modellierung der Stroemungs- und Transportprozesse im Reaktorkern eines modularen Hochtemperaturreaktors waehrend eines Lufteinbruchstoerfalls

    Energy Technology Data Exchange (ETDEWEB)

    Baggemann, Johannes

    2015-05-22

    Generation IV of reactor design is supposed to include inherent safety systems that allow accident management using passive processes (without external energy). The VTR (very high temperature reactor) is graphite moderated with helium cooling. The design concept assumes that in any operational situation the after heat is removed by thermal conduction and radiation. Air ingress is beyond-design accident assuming a leak in the primary circuit triggering oxygen reaction with the hot graphite that could damage the barriers for fission product release. Using 3D CFD (computational fluid dynamics) codes the air ingress scenario is simulated, the flow and transport processes in the reactor core are analyzed. For validation of the modeling heat transport processes were investigated in specific test facilities.

  2. Groundwater remediation engineering--Study on the flow distribution of air sparging using acetylene

    Institute of Scientific and Technical Information of China (English)

    ZHENG Yan-mei; ZHANG Ying; HUANG Guo-qiang; JIANG Bin; LI Xin-gang

    2005-01-01

    Air sparging(AS) is an emerging method to remove VOCs from saturated soils and groundwater. Air sparging performance highly depends on the air distribution resulting in the aquifer. In order to study gas flow characterization, a two-dimensional experimental chamber was designed and installed. In addition, the method by using acetylene as the tracer to directly image the gas distribution results of AS process has been put forward. Experiments were performed with different injected gas flow rates. The gas flow patterns were found to depend significantly on the injected gas flow rate, and the characterization of gas flow distributions in porous media was very different from the acetylene tracing study. Lower and higher gas flow rates generally yield more irregular in shape and less effective gas distributions.

  3. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    DEFF Research Database (Denmark)

    Skwarczynski, Mariusz; Melikov, Arsen Krikor; Kaczmarczyk, J.

    2010-01-01

    The effect of facially applied air movement on perceived air quality (PAQ) at high humidity was studied. Thirty subjects (21 males and 9 females) participated in three, 3-h experiments performed in a climate chamber. The experimental conditions covered three combinations of relative humidity...... toward the upper part of the body (upper chest, head). The subjects could control the flow rate (velocity) of the supplied air in the vicinity of their bodies. The results indicate an airflow with elevated velocity applied to the face significantly improves the acceptability of the air quality...

  4. Influences of the Air in Metal Powder High Velocity Compaction

    Directory of Open Access Journals (Sweden)

    Liu Jun

    2017-01-01

    Full Text Available During the process of metal powder high velocity impact compaction, the air is compressed sharply and portion remains in the compacts. In order to study the Influences, a discrete density volleyball accumulation model for aluminium powder was established with the use of ABAQUS. Study found that the powder porosity air obstruct the pressing process because remaining air reduced strength and density of the compacts in the current high-speed pressing (V≤100m/s. When speed further increased (V≥100m/s, the temperature of the air increased sharply, and was even much higher than the melting point of the material. When aluminium powder was compressed at a speed of 200m/s, temperatures of air could reach 2033 K, far higher than the melting point of 877 K. Increased density of powders was a result of local softening and even melt adhesive while air between particles with high temperature and pressure flowed past.

  5. Study of air-liquid flow patterns in hydrocyclone enhanced by air bubbles

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Z.; Wang, H.; Tu, S.T. [School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai (China)

    2009-01-15

    In order to improve the oil-water separation efficiency of a hydrocyclone, a new process utilizing air bubbles has been developed to enhance separation performance. Using the two-component phase Doppler particle analyzer (PDPA) technique, the velocities of two phases, air and liquid, and air bubble diameter were measured in a hydrocyclone. The air-liquid mixing pump can produce 15 to 60 {mu}m-diameter air bubbles in water. There is an optimum air-liquid ratio for oil-water separation of a hydrocyclone enhanced by air bubbles. An air core occurs in the hydrocyclone when the air-liquid ratio is more than 1 %. The velocities of air bubbles have a similar flow pattern to the water phase. The axial and tangential velocity differences of the air bubbles at different air-liquid ratio are greater near the wall and near the core of the hydrocyclone. The measured results show that the size distribution of the air bubbles produced by the air-liquid mixing pump is beneficial to the process where air bubbles capture oil droplets in the hydrocyclone. These studies are helpful to understand the separation mechanism of a hydrocyclone enhanced by air bubbles. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  6. Air cleaning efficiency of deodorant materials under dynamic conditions: effect of air flow rate

    DEFF Research Database (Denmark)

    Mizutani, Chiyomi; Bivolarova, Mariya Petrova; Melikov, Arsen Krikor

    2014-01-01

    was evaluated as deodorant materials neutralising ammonia in air. The deodorant material efficiency was tested in a special experimental set-up consisting of a straight pipe section, an ammonia gas generator, a fan and a textile frame. The deodorant materials, placed in the pipe, were exposed to a flow of air...... mixed with ammonia gas at a concentration of 20 ppm and velocities of 0.05, 0.15, 0.3 and 1.2 m/s. The activated carbon fibers treated with acid had a high deodorizing effect for ammonia (0.8) at a velocity of 0.05 m/s. The deodorizing effect of this material decreased with the increase in the velocity....... The porous activated carbon fiber fabric did not have a deodorant effect....

  7. Effect of air-flow rate and turning frequency on bio-drying of dewatered sludge.

    Science.gov (United States)

    Zhao, Ling; Gu, Wei-Mei; He, Pin-Jing; Shao, Li-Ming

    2010-12-01

    Sludge bio-drying is an approach for biomass energy utilization, in which sludge is dried by means of the heat generated by aerobic degradation of its organic substances. The study aimed at investigating the interactive influence of air-flow rate and turning frequency on water removal and biomass energy utilization. Results showed that a higher air-flow rate (0.0909m(3)h(-1)kg(-1)) led to lower temperature than did the lower one (0.0455m(3)h(-1)kg(-1)) by 17.0% and 13.7% under turning per two days and four days. With the higher air-flow rate and lower turning frequency, temperature cumulation was almost similar to that with the lower air-flow rate and higher turning frequency. The doubled air-flow rate improved the total water removal ratio by 2.86% (19.5gkg(-1) initial water) and 11.5% (75.0gkg(-1) initial water) with turning per two days and four days respectively, indicating that there was no remarkable advantage for water removal with high air-flow rate, especially with high turning frequency. The heat used for evaporation was 60.6-72.6% of the total heat consumption (34,400-45,400kJ). The higher air-flow rate enhanced volatile solids (VS) degradation thus improving heat generation by 1.95% (800kJ) and 8.96% (3200kJ) with turning per two days and four days. With the higher air-flow rate, heat consumed by sensible heat of inlet air and heat utilization efficiency for evaporation was higher than the lower one. With the higher turning frequency, sensible heat of materials and heat consumed by turning was higher than lower one.

  8. High flow nasal cannula for respiratory support in preterm infants.

    LENUS (Irish Health Repository)

    Wilkinson, Dominic

    2011-01-01

    High flow nasal cannulae (HFNC) are small, thin, tapered cannulae used to deliver oxygen or blended oxygen and air at flow rates of > 1 L\\/min. HFNC can be used to provide high concentrations of oxygen and may deliver positive end-expiratory pressure.

  9. Visualization of the air flow behind the automotive benchmark vent

    Science.gov (United States)

    Pech, Ondrej; Jedelsky, Jan; Caletka, Petr; Jicha, Miroslav

    2015-05-01

    Passenger comfort in cars depends on appropriate function of the cabin HVAC system. A great attention is therefore paid to the effective function of automotive vents and proper formation of the flow behind the ventilation outlet. The article deals with the visualization of air flow from the automotive benchmark vent. The visualization was made for two different shapes of the inlet channel connected to the benchmark vent. The smoke visualization with the laser knife was used. The influence of the shape of the inlet channel to the airflow direction, its enlargement and position of air flow axis were investigated.

  10. Visualization of the air flow behind the automotive benchmark vent

    Directory of Open Access Journals (Sweden)

    Pech Ondrej

    2015-01-01

    Full Text Available Passenger comfort in cars depends on appropriate function of the cabin HVAC system. A great attention is therefore paid to the effective function of automotive vents and proper formation of the flow behind the ventilation outlet. The article deals with the visualization of air flow from the automotive benchmark vent. The visualization was made for two different shapes of the inlet channel connected to the benchmark vent. The smoke visualization with the laser knife was used. The influence of the shape of the inlet channel to the airflow direction, its enlargement and position of air flow axis were investigated.

  11. Design and Implementation of Automatic Air Flow Rate Control System

    Science.gov (United States)

    Akbar, A.; Saputra, C.; Munir, M. M.; Khairurrijal

    2016-08-01

    Venturimeter is an apparatus that can be used to measure the air flow rate. In this experiment we designed a venturimeter which equipped with a valve that is used to control the air flow rate. The difference of pressure between the cross sections was measured with the differential pressure sensor GA 100-015WD which can calculate the difference of pressures from 0 to 3737.33 Pa. A 42M048C Z36 stepper motor was used to control the valve. The precision of this motor rotation is about 0.15 °. A Graphical User Interface (GUI) was developed to monitor and set the value of flow rate then an 8-bit microcontroller was used to process the control system In this experiment- the venturimeter has been examined to get the optimal parameter of controller. The results show that the controller can set the stable output air flow rate.

  12. 40 CFR 86.313-79 - Air flow measurement specifications; diesel engines.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Air flow measurement specifications... Procedures § 86.313-79 Air flow measurement specifications; diesel engines. (a) The air flow measurement method used must have a range large enough to accurately measure the air flow over the engine...

  13. Equipment for Measuring Air Flow, Air Temperature, Relative Humidity, and Carbon Dioxide in Schools. Technical Bulletin.

    Science.gov (United States)

    Jacobs, Bruce W.

    Information on equipment and techniques that school facility personnel may use to evaluate IAQ conditions are discussed. Focus is placed on the IAQ parameters of air flow, air temperature, relative humidity, as well as carbon dioxide and the equipment used to measure these factors. Reasons for measurement and for when the measurement of these…

  14. A coupled surface/subsurface flow model accounting for air entrapment and air pressure counterflow

    DEFF Research Database (Denmark)

    Delfs, Jens Olaf; Wang, Wenqing; Kalbacher, Thomas

    2013-01-01

    This work introduces the soil air system into integrated hydrology by simulating the flow processes and interactions of surface runoff, soil moisture and air in the shallow subsurface. The numerical model is formulated as a coupled system of partial differential equations for hydrostatic (diffusive...

  15. Laser sheet light flow visualization for evaluating room air flowsfrom Registers

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Claret, Valerie; Smith, Brian

    2006-04-01

    Forced air heating and cooling systems and whole house ventilation systems deliver air to individual rooms in a house via supply registers located on walls ceilings or floors; and occasionally less straightforward locations like toe-kicks below cabinets. Ideally, the air velocity out of the registers combined with the turbulence of the flow, vectoring of air by register vanes and geometry of register placement combine to mix the supply air within the room. A particular issue that has been raised recently is the performance of multiple capacity and air flow HVAC systems. These systems vary the air flow rate through the distribution system depending on the system load, or if operating in a ventilation rather than a space conditioning mode. These systems have been developed to maximize equipment efficiency, however, the high efficiency ratings do not include any room mixing effects. At lower air flow rates, there is the possibility that room air will be poorly mixed, leading to thermal stratification and reduced comfort for occupants. This can lead to increased energy use as the occupants adjust the thermostat settings to compensate and parts of the conditioned space have higher envelope temperature differences than for the well mixed case. In addition, lack of comfort can be a barrier to market acceptance of these higher efficiency systems To investigate the effect on room mixing of reduced air flow rates requires the measurement of mixing of supply air with room air throughout the space to be conditioned. This is a particularly difficult exercise if we want to determine the transient performance of the space conditioning system. Full scale experiments can be done in special test chambers, but the spatial resolution required to fully examine the mixing problem is usually limited by the sheer number of thermal sensors required. Current full-scale laboratory testing is therefore severely limited in its resolution. As an alternative, we used a water-filled scale model

  16. Mixing characteristics of pulsed air-assist liquid jet into an internal subsonic cross-flow

    Science.gov (United States)

    Lee, Inchul; Kang, Youngsu; Koo, Jaye

    2010-04-01

    Penetration depth, spray dispersion angle, droplet sizes in breakup processes and atomization processes are very important parameters in combustor of air-breathing engine. These processes will enhance air/fuel mixing inside the combustor. Experimental results from the pulsed air-assist liquid jet injected into a cross-flow are investigated. And experiments were conducted to a range of cross-flow velocities from 42˜136 m/s. Air is injected with 0˜300kPa, with air-assist pulsation frequency of 0˜20Hz. Pulsation frequency was modulated by solenoid valve. Phase Doppler Particle Analyzer(PDPA) was utilized to quantitatively measuring droplet characteristics. High-speed CCD camera was used to obtain injected spray structure. Pulsed air-assist liquid jet will offer rapid mixing and good liquid jet penetration. Air-assist makes a very fine droplet which generated mist-like spray. Pulsed air-assist liquid jet will introduce additional supplementary turbulent mixing and control of penetration depth into a cross-flow field. The results show that pulsation frequency has an effect on penetration, transverse velocities and droplet sizes. The experimental data generated in these studies are used for a development of active control strategies to optimize the liquid jet penetration in subsonic cross-flow conditions and predict combustion low frequency instability.

  17. Air-segmented amplitude-modulated multiplexed flow analysis.

    Science.gov (United States)

    Inui, Koji; Uemura, Takeshi; Ogusu, Takeshi; Takeuchi, Masaki; Tanaka, Hideji

    2011-01-01

    Air-segmentation is applied to amplitude-modulated multiplexed flow analysis, which we proposed recently. Sample solutions, the flow rates of which are varied periodically, are merged with reagent and/or diluent solution. The merged stream is segmented by air-bubbles and, downstream, its absorbance is measured after deaeration. The analytes in the samples are quantified from the amplitudes of the respective wave components in the absorbance. The proposed method is applied to the determinations of a food dye, phosphate ions and nitrite ions. The air-segmentation is effective for limiting amplitude damping through the axial dispersion, resulting in an improvement in sensitivity. This effect is more pronounced at shorter control periods and longer flow path lengths.

  18. Investigation of Countercurrent Helium-Air Flows in Air-ingress Accidents for VHTRs

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xiaodong; Christensen, Richard; Oh, Chang

    2013-10-03

    The primary objective of this research is to develop an extensive experimental database for the air- ingress phenomenon for the validation of computational fluid dynamics (CFD) analyses. This research is intended to be a separate-effects experimental study. However, the project team will perform a careful scaling analysis prior to designing a scaled-down test facility in order to closely tie this research with the real application. As a reference design in this study, the team will use the 600 MWth gas turbine modular helium reactor (GT-MHR) developed by General Atomic. In the test matrix of the experiments, researchers will vary the temperature and pressure of the helium— along with break size, location, shape, and orientation—to simulate deferent scenarios and to identify potential mitigation strategies. Under support of the Department of Energy, a high-temperature helium test facility has been designed and is currently being constructed at Ohio State University, primarily for high- temperature compact heat exchanger testing for the VHTR program. Once the facility is in operation (expected April 2009), this study will utilize high-temperature helium up to 900°C and 3 MPa for loss-of-coolant accident (LOCA) depressurization and air-ingress experiments. The project team will first conduct a scaling study and then design an air-ingress test facility. The major parameter to be measured in the experiments is oxygen (or nitrogen) concentration history at various locations following a LOCA scenario. The team will use two measurement techniques: 1) oxygen (or similar type) sensors employed in the flow field, which will introduce some undesirable intrusiveness, disturbing the flow, and 2) a planar laser-induced fluorescence (PLIF) imaging technique, which has no physical intrusiveness to the flow but requires a transparent window or test section that the laser beam can penetrate. The team will construct two test facilities, one for high-temperature helium tests with

  19. A coupled surface/subsurface flow model accounting for air entrapment and air pressure counterflow

    DEFF Research Database (Denmark)

    Delfs, Jens Olaf; Wang, Wenqing; Kalbacher, Thomas

    2013-01-01

    This work introduces the soil air system into integrated hydrology by simulating the flow processes and interactions of surface runoff, soil moisture and air in the shallow subsurface. The numerical model is formulated as a coupled system of partial differential equations for hydrostatic (diffusive...... algorithm, leakances operate as a valve for gas pressure in a liquid-covered porous medium facilitating the simulation of air out-break events through the land surface. General criteria are stated to guarantee stability in a sequential iterative coupling algorithm and, in addition, for leakances to control...... the mass exchange between compartments. A benchmark test, which is based on a classic experimental data set on infiltration excess (Horton) overland flow, identified a feedback mechanism between surface runoff and soil air pressures. Our study suggests that air compression in soils amplifies surface runoff...

  20. Airway blood flow response to dry air hyperventilation in sheep

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, G.H.; Baile, E.M.; Pare, P.D.

    1986-03-01

    Airway blood flow (Qaw) may be important in conditioning inspired air. To determine the effect of eucapneic dry air hyperventilation (hv) on Qaw in sheep the authors studied 7 anesthetized open-chest sheep after 25 min. of warm dry air hv. During each period of hv the authors have recorded vascular pressures, cardiac output (CO), and tracheal mucosal and inspired air temperature. Using a modification of the reference flow technique radiolabelled microspheres were injected into the left atrium to make separate measurements after humid air and dry air hv. In 4 animals a snare around the left main pulmonary artery was used following microsphere injection to prevent recirculation (entry into L lung of microspheres from the pulmonary artery). Qaw to the trachea and L lung as measured and Qaw for the R lung was estimated. After the final injection the sheep were killed and bronchi (Br) and lungs removed. Qaw (trachea plus L lung plus R lung) in 4 sheep increased from a mean of 30.8 to 67.0 ml/min. Airway mucosal temp. decreased from 39/sup 0/ to 33/sup 0/C. The authors conclude that dry air hv cools airway mucosa and increases Qaw in sheep.

  1. Measurement of bubble velocity in an air/water flow through a narrow gap by using high-speed cinematography; Ermittlung der Blasengeschwindigkeit einer Luft/Wasser-Spaltstroemung mit Hilfe der Hochgeschwindigkeitskinematographie

    Energy Technology Data Exchange (ETDEWEB)

    Koerner, S.; Friedel, L. [Technische Univ. Hamburg-Harburg, Hamburg (Germany)

    1997-12-01

    To predict the mass flow of a two phase mixture at a given pressure difference through narrow gaps, apart from the change in state of the gas phase during pressure reduction, the knowledge of the fluid dynamics on balance which occurs in the form of a relative velocity between the phases is important. These two influences were examined with the aid of high speed cinematography for a water/air bubble flow. Apart from the quick reduction in pressure due to the sudden reduction in crossection at the entry to the gap, there are no significant differences between the experimentally determined volume change in bubbles of different sizes and that calculated assuming an isothermal change in state. The mean velocity of the bubbles does not differ appreciably from that calculated assuming an homogeneous flow. [Deutsch] Zur Vorhersage des sich bei gegebener Druckdifferenz einstellenden Massenstroms eines Zweiphasengemischs durch enge Spalte ist neben der Zustandsaenderung der Gasphase waehrend der Druckabsenkung u.a. auch die Kenntnis des sich dabei einstellenden fluiddynamischen Ungleichgewichts in Form einer Relativgeschwindigkeit zwischen den Phasen von Bedeutung. Diese beiden Einfluesse wurden mit Hilfe der Hochgeschwindigkeitskinematographie fuer eine Wasser/Luft-Blasenstroemung untersucht. Abgesehen von der raschen Druckabsenkung aufgrund der ploetzlichen Querschnittsverengung im Spalteintritt treten keine nennenswerten Unterschiede zwischen den experimentell ermittelten und den unter der Annahme einer isothermen Zustandsaenderungen berechneten Volumenaenderung verschiedengrosser Blasen auf. Die mittlere Geschwindigkeit der Blasen unterscheidet sich dabei nicht wesentlich von der unter der Annahme einer homogenen Stroemung berechneten. (orig.)

  2. Adapting the Forchheimer equation for the flow of air through wheat straw beds

    Directory of Open Access Journals (Sweden)

    Doder Đorđije D.

    2016-01-01

    Full Text Available The paper presents the results of an experimental investigation of air pressure drop while flowing through wheat straw beds. According to Darcy’s law, the smaller the porosity of the bed is, the bigger the pressure drop will be. The investigation was conducted using three different porosities (or three bed densities, and for two different air flow rates. After determining porosity (which is directly measurable, the permeability of straw could be found. For high flow velocities, such as the velocity of air flowing through a straw bale, the Forchheimer equation becomes more relevant as a correction of Darcy’s law with inertial effects included. Otherwise, the permeability tensor depends only on the geometry of the porous medium. With permeability known, the Forchheimer equation coefficients can be easily estimated. These results may be important for the future development of efficient biomass combustion facilities. The measurement methods and facility characteristics are described in more detail.

  3. An experimental study of geyser-like flows induced by a pressurized air pocket

    Science.gov (United States)

    Elayeb, I. S.; Leon, A.; Choi, Y.; Alnahit, A. O.

    2015-12-01

    Previous studies argues that the entrapment of pressurized air pockets within combined sewer systems can produce geyser flows, which is an oscillating jetting of a mixture of gas-liquid flows. To verify that pressurized air pockets can effectively produce geysers, laboratory experiments were conducted. However, past experiments were conducted in relatively small-scale apparatus (i.e. maximum φ2" vertical shaft). This study conducted a set of experiments in a larger apparatus. The experimental setup consists of an upstream head tank, a downstream head tank, a horizontal pipe (46.5ft long, φ6") and a vertical pipe (10ft long, φ6"). The initial condition for the experiments is constant flow discharge through the horizontal pipe. The experiments are initiated by injecting an air pocket with pre-determined volume and pressure at the upstream end of the horizontal pipe. The air pocket propagates through the horizontal pipe until it arrives to the vertical shaft, where it is released producing a geyser-like flow. Three flow rates in the horizontal pipe and three injected air pressures were tested. The variables measured were pressure at two locations in the horizontal pipe and two locations in the vertical pipe. High resolution videos at two regions in the vertical shaft were also recorded. To gain further insights in the physics of air-water interaction, the laboratory experiments were complemented with numerical simulations conducted using a commercial 3D CFD model, previously validated with experiments.

  4. Evolutionary Concepts for Decentralized Air Traffic Flow Management

    Science.gov (United States)

    Adams, Milton; Kolitz, Stephan; Milner, Joseph; Odoni, Amedeo

    1997-01-01

    Alternative concepts for modifying the policies and procedures under which the air traffic flow management system operates are described, and an approach to the evaluation of those concepts is discussed. Here, air traffic flow management includes all activities related to the management of the flow of aircraft and related system resources from 'block to block.' The alternative concepts represent stages in the evolution from the current system, in which air traffic management decision making is largely centralized within the FAA, to a more decentralized approach wherein the airlines and other airspace users collaborate in air traffic management decision making with the FAA. The emphasis in the discussion is on a viable medium-term partially decentralized scenario representing a phase of this evolution that is consistent with the decision-making approaches embodied in proposed Free Flight concepts for air traffic management. System-level metrics for analyzing and evaluating the various alternatives are defined, and a simulation testbed developed to generate values for those metrics is described. The fundamental issue of modeling airline behavior in decentralized environments is also raised, and an example of such a model, which deals with the preservation of flight bank integrity in hub airports, is presented.

  5. Air-flow sensitive hairs: boundary layers in oscillatory flows around arthropod appendages

    NARCIS (Netherlands)

    Steinmann, T.; Casas, J.; Krijnen, Gijsbertus J.M.; Dangles, O.

    2006-01-01

    The aim of this work is to characterize the boundary layer over small appendages in insects in longitudinal and transverse oscillatory flows. The problem of immediate interest is the early warning system in crickets perceiving flying predators using air-flow-sensitive hairs on cerci, two long

  6. Air-flow sensitive hairs: boundary layers in oscillatory flows around arthropod appendages

    NARCIS (Netherlands)

    Steinmann, T.; Casas, J.; Krijnen, G.J.M.; Dangles, O.

    2006-01-01

    The aim of this work is to characterize the boundary layer over small appendages in insects in longitudinal and transverse oscillatory flows. The problem of immediate interest is the early warning system in crickets perceiving flying predators using air-flow-sensitive hairs on cerci, two long append

  7. Discharge characteristics in inhomogeneous fields under air flow

    DEFF Research Database (Denmark)

    Vogel, Stephan; Holbøll, Joachim

    2017-01-01

    was connected to a variable DC potential of up to 100kV over a grounded plate in order to trigger different corona modes. The impact of the air flow on the space charges created in the vicinity of the electrode is evaluated by means of PD measurements in time domain. The results indicate that the wind increases...

  8. Air Flow Detection in Crude Oil by Infrared Light

    Directory of Open Access Journals (Sweden)

    Guilherme Dutra

    2017-06-01

    Full Text Available In this paper, we used infrared light in the range of 8–12 μm to develop and test an optical imaging system to detect air bubbles flowing in oil. The system basically comprises a broadband light source and a 31 × 32 thermopile array to generate images. To analyze the effects related to light absorption, reflection, and refraction on air-oil boundaries, a numerical model was developed and the predominance of the refraction instead of the absorption in bubbles with diameters below a certain critical value was observed. The IR region of the electromagnetic spectrum has both optical and thermic behavior. To understand the limits of each effect on the oil flow imaging, a study of the influence of temperature variation on the petroleum optical detection was performed. The developed optical imaging system allowed the detection of air flow in static oil and in oil-air two-phase flow. With the presented system, it was possible to achieve images through up to 12 mm of oil volumes, but this may be enhanced by the use of optimized IR sources and detectors.

  9. A Study of the Gas Flow through Air Jet Loom

    Institute of Scientific and Technical Information of China (English)

    Heuy-Dong Kim; Chae-Min Lim; Ho-Joon Lee; Doo-Hwan Chun

    2007-01-01

    Air jet loom, as one of the shuttleless looms, transports a yarn into warps using viscosity and kinetic energy of an air jet. Performance of this picking system depends on the ability of instantaneous inhalation/exhaust, configuration of nozzle, operation characteristics of a check valve, etc. In the recent past, many studies have been reported on the air jet discharged from a nozzle exit, but studies for understanding the flow field characteristics associated with shear layer and shock wave/boundary layer interaction in the nozzle were not conducted enough. In this paper, a computational study was performed to explain the flow field in the air jet nozzle with an acceleration tube and validated with previous experimental data available. The results obtained from the computational study show that, in the supersonic flow regime, the flow field depends significantly on the length of acceleration tube. As nozzle pressure ratio increases, drag force acting on the string also increases. For a longer acceleration tube, the total pressure loss is large, owing to the frictional loss.

  10. Litter ammonia losses amplified by higher air flow rates

    Science.gov (United States)

    ABSTRACT Broiler litter utilization has largely been associated with land application as fertilizer. Reducing ammonia (NH3) released from litter enhances its fertilizer value and negates detrimental impacts to the environment. A laboratory study was conducted to quantify the effect of air flow var...

  11. A MEMS-based Air Flow Sensor with a Free-standing Micro-cantilever Structure

    Directory of Open Access Journals (Sweden)

    Che-Ming Chiang

    2007-10-01

    Full Text Available This paper presents a micro-scale air flow sensor based on a free-standingcantilever structure. In the fabrication process, MEMS techniques are used to deposit asilicon nitride layer on a silicon wafer. A platinum layer is deposited on the silicon nitridelayer to form a piezoresistor, and the resulting structure is then etched to create afreestanding micro-cantilever. When an air flow passes over the surface of the cantileverbeam, the beam deflects in the downward direction, resulting in a small variation in theresistance of the piezoelectric layer. The air flow velocity is determined by measuring thechange in resistance using an external LCR meter. The experimental results indicate that theflow sensor has a high sensitivity (0.0284 ω/ms-1, a high velocity measurement limit (45ms-1 and a rapid response time (0.53 s.

  12. Relating water and air flow characteristics in coarse granular materials

    DEFF Research Database (Denmark)

    Andreasen, Rune Røjgaard; Canga, Eriona; Poulsen, Tjalfe Gorm

    2013-01-01

    Water pressure drop as a function of velocity controls w 1 ater cleaning biofilter operation 2 cost. At present this relationship in biofilter materials must be determined experimentally as no 3 universal link between pressure drop, velocity and filter material properties have been established. 4...... Pressure drop - velocity in porous media is much simpler and faster to measure for air than for water. 5 For soils and similar materials, observations show a strong connection between pressure drop – 6 velocity relations for air and water, indicating that water pressure drop – velocity may be estimated 7...... from air flow data. The objective of this study was, therefore, to investigate if this approach is valid 8 also for coarse granular biofilter media which usually consists of much larger particles than soils. In 9 this paper the connection between the pressure drop – velocity relationships for air...

  13. Parametric Studies of Flow Separation using Air Injection

    Science.gov (United States)

    Zhang, Wei

    2004-01-01

    Boundary Layer separation causes the airfoil to stall and therefore imposes dramatic performance degradation on the airfoil. In recent years, flow separation control has been one of the active research areas in the field of aerodynamics due to its promising performance improvements on the lifting device. These active flow separation control techniques include steady and unsteady air injection as well as suction on the airfoil surface etc. This paper will be focusing on the steady and unsteady air injection on the airfoil. Although wind tunnel experiments revealed that the performance improvements on the airfoil using injection techniques, the details of how the key variables such as air injection slot geometry and air injection angle etc impact the effectiveness of flow separation control via air injection has not been studied. A parametric study of both steady and unsteady air injection active flow control will be the main objective for this summer. For steady injection, the key variables include the slot geometry, orientation, spacing, air injection velocity as well as the injection angle. For unsteady injection, the injection frequency will also be investigated. Key metrics such as lift coefficient, drag coefficient, total pressure loss and total injection mass will be used to measure the effectiveness of the control technique. A design of experiments using the Box-Behnken Design is set up in order to determine how each of the variables affects each of the key metrics. Design of experiment is used so that the number of experimental runs will be at minimum and still be able to predict which variables are the key contributors to the responses. The experiments will then be conducted in the 1ft by 1ft wind tunnel according to the design of experiment settings. The data obtained from the experiments will be imported into JMP, statistical software, to generate sets of response surface equations which represent the statistical empirical model for each of the metrics as

  14. 3-dimensional Simulation of an Air-lift Pump from Bubbly to Slug Flow

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hongrae; Jo, Daeseong [Kyungpook National Univ, Daegu (Korea, Republic of)

    2015-10-15

    The air-lift pump has been used in various applications with its merit that it can pump up without any moving parts. E.g. coffee percolator, petroleum industry, suction dredge, OTEC i.e. ocean thermal energy conversion and so on. By the merit, it has high durability for high temperature water or vapor, and fluid-solid mixture like waste water, muddy water and crude, which cause problems when it's pumped up with general pumps. In this regard, the air-lift pump has been one of the most desirable technology. A typical air-lift pump configuration is illustrated in Figure 01. The principle of this pump is very simple. When air is injected from the injector at bottom of a submerged tube, i.e., air bubbles are suspended in the liquid, the average density of the mixture in the tube is less than that of the surrounding fluid in the reservoir. Then hydrostatic pressure over the length of the tube is decreased. This buoyancy force causes a pumping action. The comparison of the simulated results, experimental result, and theoretical result is been able by data shown as Figure 04. They have similar trends but they also have a little differences because there are some limits of simulating the flow regimes. At the different flow condition, different coefficients for friction factor or pressure drop should be used, but this simulation uses a laminar condition and the theoretical equations are valid only for slug regime where the air flow rate is lower than the other regimes. From these causes, the differences has arisen, and difference comes bigger as the air flow rate increases, i.e., becoming annular flow regime or churn flow regime.

  15. Flow over a Modern Ram-Air Parachute Canopy

    Science.gov (United States)

    Mohammadi, Mohammad; Johari, Hamid

    2010-11-01

    The flow field on the central section of a modern ram-air parachute canopy was examined numerically using a finite-volume flow solver coupled with the one equation Spalart-Allmaras turbulence model. Ram-air parachutes are used for guided airdrop applications, and the canopy resembles a wing with an open leading edge for inflation. The canopy surfaces were assumed to be impermeable and rigid. The flow field consisted of a vortex inside the leading edge opening which effectively closed off the canopy and diverted the flow around the leading edge. The flow experienced a rather bluff leading edge in contrast to the smooth leading of an airfoil, leading to a separation bubble on the lower lip of the canopy. The flow inside the canopy was stagnant beyond the halfway point. The section lift coefficient increased linearly with the angle of attack up to 8.5 and the lift curve slope was about 8% smaller than the baseline airfoil. The leading edge opening had a major effect on the drag prior to stall; the drag is at least twice the baseline airfoil drag. The minimum drag of the section occurs over the angle of attack range of 3 -- 7 .

  16. Evaluation of Air Mixing and Thermal Comfort From High Sidewall Supply Air Jets

    Energy Technology Data Exchange (ETDEWEB)

    Ridouane, El Hassan [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-09-01

    Uniform mixing of conditioned air with room air is an essential factor for providing comfort in homes. The objective of the study outlined in this report is to resolve the issue that the flow rates that are required to meet the small remaining thermal loads are not large enough to maintain uniform mixing in the space.and maintain uniform temperatures within future homes. The results provide information to guide the selection of high sidewall supply diffusers to maintain proper room mixing for heating and cooling of high performance homes.

  17. Investigation on Plasma Jet Flow Phenomena During DC Air Arc Motion in Bridge-Type Contacts

    Science.gov (United States)

    Zhai, Guofu; Bo, Kai; Chen, Mo; Zhou, Xue; Qiao, Xinlei

    2016-05-01

    Arc plasma jet flow in the air was investigated under a bridge-type contacts in a DC 270 V resistive circuit. We characterized the arc plasma jet flow appearance at different currents by using high-speed photography, and two polished contacts were used to search for the relationship between roughness and plasma jet flow. Then, to make the nature of arc plasma jet flow phenomena clear, a simplified model based on magnetohydrodynamic (MHD) theory was established and calculated. The simulated DC arc plasma was presented with the temperature distribution and the current density distribution. Furthermore, the calculated arc flow velocity field showed that the circular vortex was an embodiment of the arc plasma jet flow progress. The combined action of volume force and contact surface was the main reason of the arc jet flow. supported by National Natural Science Foundation of China (Nos. 51307030, 51277038)

  18. Investigation on Plasma Jet Flow Phenomena During DC Air Arc Motion in Bridge-Type Contacts

    Institute of Scientific and Technical Information of China (English)

    ZHAI Guofu; BO Kai; CHEN Mo; ZHOU Xue; QIAO Xinlei

    2016-01-01

    Arc plasma jet flow in the air was investigated under a bridge-type contacts in a DC 270 V resistive circuit.We characterized the arc plasma jet flow appearance at different currents by using high-speed photography,and two polished contacts were used to search for the relationship between roughness and plasma jet flow.Then,to make the nature of arc plasma jet flow phenomena clear,a simplified model based on magnetohydrodynamic (MHD) theory was established and calculated.The simulated DC arc plasma was presented with the temperature distribution and the current density distribution.Furthermore,the calculated arc flow vclocity field showed that the circular vortex was an embodiment of the arc plasma jet flow progress.The combined action of volume force and contact surface was the main reason of the arc jet flow.

  19. Correlation of Forced-convection Heat-transfer Data for Air Flowing in Smooth Platinum Tube with Long-approach Entrance at High Surface and Inlet-air Temperatures

    Science.gov (United States)

    Desmon, Leland G; Sams, Eldon W

    1950-01-01

    A heat-transfer investigation was conducted with air in an electrically heated platinum tube with long-approach entrance, inside diameter of 0.525 inch, and effective heat-transfer length of 24 inches over ranges of Reynolds number up to 320,000, average inside-tube-wall temperature up to 3053 degrees R, and inlet-air temperature up to 1165 degrees R. Correlation of data by the conventional Nusselt relation resulted in separation of data with tube-wall temperature. Good correlation was obtained, however, by use of a modified Reynolds number.

  20. Neutron imaging of diabatic two-phase flows relevant to air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Geoghegan, Patrick J [ORNL; Sharma, Vishaldeep [ORNL

    2017-01-01

    The design of the evaporator of an air conditioning system relies heavily on heat transfer coefficients and pressure drop correlations that predominantly involve an estimate of the changing void fraction and the underlying two-phase flow regime. These correlations dictate whether the resulting heat exchanger is oversized or not and the amount of refrigerant charge necessary to operate. The latter is particularly important when dealing with flammable or high GWP refrigerants. Traditional techniques to measure the void fraction and visualize the flow are either invasive to the flow or occur downstream of the evaporator, where some of the flow distribution will have changed. Neutron imaging has the potential to visualize two-phase flow in-situ where an aluminium heat exchanger structure becomes essentially transparent to the penetrating neutrons. The subatomic particles are attenuated by the passing refrigerant flow. The resulting image may be directly related to the void fraction and the overall picture provides a clear insight into the flow regime present. This work presents neutron images of the refrigerant Isopentane as it passes through the flow channels of an aluminium evaporator at flowrates relevant to air conditioning. The flow in a 4mm square macro channel is compared to that in a 250 m by 750 m rectangular microchannel in terms of void fraction and regime. All neutron imaging experiments were conducted at the High Flux Isotope Reactor, an Oak Ridge National Laboratory facility

  1. Transboundary High School Air Quality Education Program

    Energy Technology Data Exchange (ETDEWEB)

    Hinkle, I. [Cascadia AirNET, Bellingham, WA (United States)

    2004-04-07

    A study was conducted to determine why the air quality in the Cascadia bioregion is declining. The Cascadia bioregion extends from the Alaska border in northern British Columbia to the northern coast of California and is bounded by the Pacific Ocean and the Cascade Mountains. The region shares resources such as air, water, soil migration, wildlife, human power, flora, and aquatic life. It has one of the fastest growing populations in Canada and the United States. AirNet is a school-based program that was established to promote environmental cooperation between the two countries and to increase citizen understanding and participation in protecting air quality and biodiversity. The objective of AirNet is to increase trans-border cooperation by non-governmental organizations, governments, scientists, citizens and educational facilities. AirNet shares biomonitoring data world-wide. The 5 components of the AirNet program are: (1) a teacher training workshop, (2) classroom presentations by AirNet staff on general air quality issues, (3) a presentation on lichen classification and identification, (4) a field trip with AirNet personnel to gather biomonitoring data, and (5) a follow-up field trip to use the PAX Air Quality Analyzer which analyzes biomonitoring data for carbon monoxide, carbon dioxide, ozone, sulphur dioxide, nitrogen dioxide, and particulates. PAX can also analyze wind speed, wind direction, temperature, humidity and barometric pressure. Results from a lichen study at Port Moody High School in British Columbia indicated high levels of sulphur dioxide in areas of lichen absence. In response, the students requested that the industrial facility upwind from the area cover its solid sulphur piles. The study raised awareness of bioindicators for air and applied student Internet knowledge and capability to real-life science. tabs., figs.

  2. Measurement of velocity of air flow in the sinus maxillaris.

    Science.gov (United States)

    Müsebeck, K; Rosenberg, H

    1979-03-01

    Anemometry with the hot wire and hot film technique previously described, enables the rhinologist to record slow and rapidly changing air flow in the maxillary sinus. The advantages and disadvantages of this method are considered. Anemometry together with manometry may be designated sinumetry and used as a diagnostic procedure following sinuscopy in chronic maxillary sinus disease. The value of the function from velocity of time allows the estimation of flow-volume in the sinus. Furthermore, the method is useful to evaluate the optimal therapy to restore ventilation in the case of an obstructed ostium demonstrated before and after surgical opening in the inferior meatus.

  3. Calculation of the dynamic air flow resistivity of fibre materials

    DEFF Research Database (Denmark)

    Tarnow, Viggo

    1997-01-01

    The acoustic attenuation of acoustic fiber materials is mainly determined by the dynamic resistivity to an oscillating air flow. The dynamic resistance is calculated for a model with geometry close to the geometry of real fibre material. The model constists of parallel cylinders placed randomly. ......-consistent procedure gives the same results as the more complicated procedure based on average over Voronoi cells. Graphs of the dynamic resistivity versus frequency are given for fiber densities and diameters typical for acoustic fiber materials.......The acoustic attenuation of acoustic fiber materials is mainly determined by the dynamic resistivity to an oscillating air flow. The dynamic resistance is calculated for a model with geometry close to the geometry of real fibre material. The model constists of parallel cylinders placed randomly...

  4. Vision and air flow combine to streamline flying honeybees.

    Science.gov (United States)

    Taylor, Gavin J; Luu, Tien; Ball, David; Srinivasan, Mandyam V

    2013-01-01

    Insects face the challenge of integrating multi-sensory information to control their flight. Here we study a 'streamlining' response in honeybees, whereby honeybees raise their abdomen to reduce drag. We find that this response, which was recently reported to be mediated by optic flow, is also strongly modulated by the presence of air flow simulating a head wind. The Johnston's organs in the antennae were found to play a role in the measurement of the air speed that is used to control the streamlining response. The response to a combination of visual motion and wind is complex and can be explained by a model that incorporates a non-linear combination of the two stimuli. The use of visual and mechanosensory cues increases the strength of the streamlining response when the stimuli are present concurrently. We propose this multisensory integration will make the response more robust to transient disturbances in either modality.

  5. Interrelationships of petiole air canal architecture, water depth and convective air flow in Nymphaea odorata (Nymphaeaceae)

    Science.gov (United States)

    Premise of the study--Nymphaea odorata grows in water up to 2 m deep, producing fewer, larger leaves in deeper water. This species has a convective flow system that moves gases from younger leaves through submerged parts to older leaves, aerating submerged parts. Petiole air canals are in the conv...

  6. STUDY OF THE AIR FLOWS AROUND AN AIRPLANE

    Directory of Open Access Journals (Sweden)

    Diaconescu Olivian

    2013-06-01

    Full Text Available This material presents a stage of the designing of an airplane capable to work with low capacity engines of 2.5 and 4 cmc namely the simulation of the air flow around the fuselage and the wings. The study proves the correctness of the choice made in the wing’s positioning and of the horizontal stabilizer of the airplane’s axis,for the chosen airplane type namely acrobat.

  7. High-Compression-Ratio; Atkinson-Cycle Engine Using Low-Pressure Direct Injection and Pneumatic-Electronic Valve Actuation Enabled by Ionization Current and Foward-Backward Mass Air Flow Sensor Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Harold Schock; Farhad Jaberi; Ahmed Naguib; Guoming Zhu; David Hung

    2007-12-31

    This report describes the work completed over a two and one half year effort sponsored by the US Department of Energy. The goal was to demonstrate the technology needed to produce a highly efficient engine enabled by several technologies which were to be developed in the course of the work. The technologies included: (1) A low-pressure direct injection system; (2) A mass air flow sensor which would measure the net airflow into the engine on a per cycle basis; (3) A feedback control system enabled by measuring ionization current signals from the spark plug gap; and (4) An infinitely variable cam actuation system based on a pneumatic-hydraulic valve actuation These developments were supplemented by the use of advanced large eddy simulations as well as evaluations of fuel air mixing using the KIVA and WAVE models. The simulations were accompanied by experimental verification when possible. In this effort a solid base has been established for continued development of the advanced engine concepts originally proposed. Due to problems with the valve actuation system a complete demonstration of the engine concept originally proposed was not possible. Some of the highlights that were accomplished during this effort are: (1) A forward-backward mass air flow sensor has been developed and a patent application for the device has been submitted. We are optimistic that this technology will have a particular application in variable valve timing direct injection systems for IC engines. (2) The biggest effort on this project has involved the development of the pneumatic-hydraulic valve actuation system. This system was originally purchased from Cargine, a Swedish supplier and is in the development stage. To date we have not been able to use the actuators to control the exhaust valves, although the actuators have been successfully employed to control the intake valves. The reason for this is the additional complication associated with variable back pressure on the exhaust valves when

  8. Numerical characterization of the hydrodynamics and thermal behavior of air flow in flexible air distribution system

    Science.gov (United States)

    Gharehdaghi, Samad; Moujaes, Samir

    2013-10-01

    Flexible duct air distribution systems are used in a large percentage of residential and small commercial buildings in the United States . Very few empirical or predictive data are available though to help provide the HVAC design engineer with reliable information . Moreover, because of the ducts flexibility, the shapes of these ducts offer a different set of operating fluid flow and thermal conditions from traditional smooth metal ducts. Hence, both the flow field and heat transfer through this kind of ducts are much more complex and merit to be analyzed from a numerical predictive approach. The aim of this research paper is to compute some of the hydrodynamic and heat transfer characteristics of the air flow inside these ducts over a range of Re numbers commonly used in the flow conditions of these air distribution systems. The information resulting from this CFD simulation, where a κ-ɛ turbulent model is used to predict the flow conditions, provide pressure drop and average convective heat transfer coefficients that exist in these ducts and was compared to previously found data. Circulation zones in the depressions of these ducts are found to exist which are suspected of influencing the pressured drop and heat transfer coefficients as compared to smooth ducts. The results show that fully developed conditions exist much earlier with regard to the inlet for both hydrodynamic and thermal entrance regions than what would be expected in smooth ducts under the same turbulent conditions.

  9. SONIC SPEED AND SHOCK WAVE IN HIGH VELOCITY AERATED FLOWS FROM HIGH HEAD DISCHARGE STRUCTURES

    Institute of Scientific and Technical Information of China (English)

    Dong Zhi-yong

    2003-01-01

    The compressible characteristics in aerated flows at the high velocity of about 50m/s were analyzed. Based on the theory of compressible the relations between the sonic speed and shock wave in high-velocity aerated flow were theoretically deduced. And comparisons with measured data were made. The theoretical and experimental results show the sonic speed in aerated flow is merely of the order of several-dozen meters per second, and its minimum value is only 20m/s, which is far much less than that in water or air alone. So high subsonic flow, supersonic flow and transonic flow as well as compression wave, shock wave and expansion wave similarly to aerodnamics may be produced in high velocity aerated flow at the speed of the order of 50m/s. Hence the influences of these compressible characteristics on high head discharge structures can not be neglected, especially on super high dams over 200m high.

  10. Propulsive jet simulation with air and helium in launcher wake flows

    Science.gov (United States)

    Stephan, Sören; Radespiel, Rolf

    2016-12-01

    The influence on the turbulent wake of a generic space launcher model due to the presence of an under-expanded jet is investigated experimentally. Wake flow phenomena represent a significant source of uncertainties in the design of a space launcher. Especially critical are dynamic loads on the structure. The wake flow is investigated at supersonic (M=2.9 ) and hypersonic (M=5.9 ) flow regimes. The jet flow is simulated using air and helium as working gas. Due to the lower molar mass of helium, higher jet velocities are realized, and therefore, velocity ratios similar to space launchers can be simulated. The degree of under-expansion of the jet is moderate for the supersonic case (p_e/p_∞ ≈ 5 ) and high for the hypersonic case (p_e/p_∞ ≈ 90 ). The flow topology is described by Schlieren visualization and mean-pressure measurements. Unsteady pressure measurements are performed to describe the dynamic wake flow. The influences of the under-expanded jet and different jet velocities are reported. On the base fluctuations at a Strouhal number, around St_D ≈ 0.25 dominate for supersonic free-stream flows. With air jet, a fluctuation-level increase on the base is observed for Strouhal numbers above St_D ≈ 0.75 in hypersonic flow regime. With helium jet, distinct peaks at higher frequencies are found. This is attributed to the interactions of wake flow and jet.

  11. Optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits.

    Science.gov (United States)

    Ozkan, Fahri; Tuna, M Cihat; Baylar, Ahmet; Ozturk, Mualla

    2014-01-01

    Oxygen is an important component of water quality and its ability to sustain life. Water aeration is the process of introducing air into a body of water to increase its oxygen saturation. Water aeration can be accomplished in a variety of ways, for instance, closed-conduit aeration. High-speed flow in a closed conduit involves air-water mixture flow. The air flow results from the subatmospheric pressure downstream of the gate. The air entrained by the high-speed flow is supplied by the air vent. The air entrained into the flow in the form of a large number of bubbles accelerates oxygen transfer and hence also increases aeration efficiency. In the present work, the optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits was studied experimentally. Results showed that aeration efficiency increased with the air-demand ratio to a certain point and then aeration efficiency did not change with a further increase of the air-demand ratio. Thus, there was an optimum value for the air-demand ratio, depending on the Froude number, which provides maximum aeration efficiency. Furthermore, a design formula for aeration efficiency was presented relating aeration efficiency to the air-demand ratio and Froude number.

  12. 30 CFR 75.152 - Tests of air flow; qualified person.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of air flow; qualified person. 75.152....152 Tests of air flow; qualified person. A person is a qualified person within the meaning of the provisions of Subpart D—Ventilation of this part requiring that tests of air flow be made by a...

  13. Two-phase air-water flows:Scale effects in physical modeling

    Institute of Scientific and Technical Information of China (English)

    PFISTER Michael; CHANSON Hubert

    2014-01-01

    Physical modeling represents probably the oldest design tool in hydraulic engineering together with analytical approaches. In free surface flows, the similitude based upon a Froude similarity allows for a correct representation of the dominant forces, namely gravity and inertia. As a result fluid flow properties such as the capillary forces and the viscous forces might be incorrectly reproduced, affecting the air entrainment and transport capacity of a high-speed model flow. Small physical models operating under a Froude similitude systematically underestimate the air entrainment rate and air-water interfacial properties. To limit scale effects, minimal values of Reynolds or Weber number have to be respected. The present article summarizes the physical background of such limitations and their combination in terms of the Morton number. Based upon a literature review, the existing limits are presented and discussed, resulting in a series of more conservative recommendations in terms of air concentration scaling. For other air-water flow parameters, the selection of the criteria to assess scale effects is critical because some parameters (e.g., bubble sizes, turbulent scales) can be affected by scale effects, even in relatively large laboratory models.

  14. Flow over a Ram-Air Parachute Canopy

    Science.gov (United States)

    Eslambolchi, Ali; Johari, Hamid

    2012-11-01

    The flow field over a full-scale, ram-air personnel parachute canopy was investigated numerically using a finite-volume flow solver coupled with the Spalart-Allmaras turbulence model. Ram-air parachute canopies resemble wings with arc-anhedral, surface protuberances, and an open leading edge for inflation. The rectangular planform canopy had an aspect ratio of 2.2 and was assumed to be rigid and impermeable. The chord-based Reynolds number was 3.2 million. Results indicate that the oncoming flow barely penetrates the canopy opening, and creates a large separation bubble below the lower lip of canopy. A thick boundary layer exists over the entire lower surface of the canopy. The flow over the upper surface of the canopy remains attached for an extended fraction of the chord. Lift increases linearly with angle of attack up to about 12 degrees. To assess the capability of lifting-line theory in predicting the forces on the canopy, the lift and drag data from a two-dimensional simulation of the canopy profile were extended using finite-wing expressions and compared with the forces from the present simulations. The finite-wing predicted lift and drag trends compare poorly against the full-span simulation, and the maximum lift-to-drag ratio is over-predicted by 36%. Sponsored by the US Army NRDEC.

  15. Implications of Air Ingress Induced by Density-Difference Driven Stratified Flow

    Energy Technology Data Exchange (ETDEWEB)

    Chang Oh; Eung Soo Kim; Richard Schultz; David Petti; C. P. Liou

    2008-06-01

    One of the design basis accidents for the Next Generation Nuclear Plant (NGNP), a high temperature gas-cooled reactor, is air ingress subsequent to a pipe break. Following a postulated double-ended guillotine break in the hot duct, and the subsequent depressurization to nearly reactor cavity pressure levels, air present in the reactor cavity will enter the reactor vessel via density-gradient-driven-stratified flow. Because of the significantly higher molecular weight and lower initial temperature of the reactor cavity air-helium mixture, in contrast to the helium in the reactor vessel, the air-helium mixture in the cavity always has a larger density than the helium discharging from the reactor vessel through the break into the reactor cavity. In the later stages of the helium blowdown, the momentum of the helium flow decreases sufficiently for the heavier cavity air-helium mixture to intrude into the reactor vessel lower plenum through the lower portion of the break. Once it has entered, the heavier gas will pool at the bottom of the lower plenum. From there it will move upwards into the core via diffusion and density-gradient effects that stem from heating the air-helium mixture and from the pressure differences between the reactor cavity and the reactor vessel. This scenario (considering density-gradient-driven stratified flow) is considerably different from the heretofore commonly used scenario that attributes movement of air into the reactor vessel and from thence to the core region via diffusion. When density-gradient-driven stratified flow is considered as a contributing phenomena for air ingress into the reactor vessel, the following factors contribute to a much earlier natural circulation-phase in the reactor vessel: (a) density-gradient-driven stratified flow is a much more rapid mechanism (at least one order of magnitude) for moving air into the reactor vessel lower plenum than diffusion, and consequently, (b) the diffusion dominated phase begins with a

  16. Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.; Lowenstein, A.

    2014-09-01

    Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by first overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.

  17. Compressible air flow through a collapsing liquid cavity

    CERN Document Server

    Gordillo, Stephan Gekle \\and José Manuel

    2010-01-01

    We present a multiscale approach to simulate the impact of a solid object on a liquid surface: upon impact a thin liquid sheet is thrown upwards all around the rim of the impactor while in its wake a large surface cavity forms. Under the influence of hydrostatic pressure the cavity immediately starts to collapse and eventually closes in a single point from which a thin, needle-like jet is ejected. Existing numerical treatments of liquid impact either consider the surrounding air as an incompressible fluid or neglect air effects altogether. In contrast, our approach couples a boundary-integral method for the liquid with a Roe scheme for the gas domain and is thus able to handle the fully \\emph{compressible} gas stream that is pushed out of the collapsing impact cavity. Taking into account air compressibility is crucial, since, as we show in this work, the impact crater collapses so violently that the air flow through the cavity neck attains supersonic velocities already at cavity diameters larger than 1 mm. Ou...

  18. Numerical study of cross flow fan performance in an indoor air conditioning unit

    Science.gov (United States)

    Yet, New Mei; Raghavan, Vijay R.; Chinc, W. M.

    2012-06-01

    The cross flow fan is a unique type of turbo machinery where the air stream flows transversely across the impeller, passing the blades twice. Due to its complex geometry, and highly turbulent and unsteady air-flow, a numerical method is used in this work to conduct the characterization study on the performance of a cross flow fan. A 2D cross-sectional model of a typical indoor air conditioning unit has been chosen for the simulation instead of a three dimensional 3D model due to the highly complex geometry of the fan. The simplified 2D model has been validated with experiments where it is found that the RMS error between the simulation and experimental results is less than 7%. The important parameters that affect the cross flow fan performance, i.e. the internal and external blade angles, the blade thickness, and the casing design, are analyzed in this study. The formation of an eccentric vortex is observed within the impeller.

  19. Air Flows in Gravity Sewers - Determination of Wastewater Drag Coefficient

    DEFF Research Database (Denmark)

    Bentzen, Thomas Ruby; Østertoft, Kristian; Vollertsen, Jes

    2016-01-01

    of the study shows that by integrating the top/side wall shear stresses the log-law models for the air velocity distribution along the unwetted perimeter resulted in a good agreement with the friction forces calculated by use of the Colebrook-White formula for hydraulic smooth pipes. Secondly, the water......Several experiments have been conducted in order to improve the understanding of the wastewater drag and the wall frictional force acting on the headspace air in gravity sewers. The aim of the study is to improve the data basis for a numerical model of natural sewer ventilation. The results...... surface drags were found by log-law models of the velocity distribution in turbulent flows to fit velocity profiles measured from the water surface and by integrating the water surface drags along the wetted perimeter, mean water surface drags were found and a measure of the water surface drag coefficient...

  20. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain; Stratton, Chris

    2015-07-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

  1. Evaluation of Air Mixing and Thermal Comfort From High Sidewall Supply Air Jets

    Energy Technology Data Exchange (ETDEWEB)

    Ridouane, E. H.

    2011-09-01

    Uniform mixing of conditioned air with room air is an essential factor for providing comfort in homes. The higher the supply flow rates the easier to reach good mixing in the space. In high performance homes, however, the flow rates required to meet the small remaining thermal loads are not large enough to maintain uniform mixing in the space. The objective of this study is to resolve this issue and maintain uniform temperatures within future homes. We used computational fluid dynamics modeling to evaluate the performance of high sidewall air supply for residential applications in heating and cooling modes. Parameters of the study are the supply velocity, supply temperature, diffuser dimensions, and room dimensions. Laboratory experiments supported the study of thermal mixing in heating mode; we used the results to develop a correlation to predict high sidewall diffuser performance. For cooling mode, numerical analysis is presented. The results provide information to guide the selection of high sidewall supply diffusers to maintain proper room mixing for heating and cooling of high performance homes. It is proven that these systems can achieve good mixing and provide acceptable comfort levels. Recommendations are given on the operating conditions to guarantee occupant comfort.

  2. Air flow paths and porosity/permeability change in a saturated zone during in situ air sparging.

    Science.gov (United States)

    Tsai, Yih-Jin

    2007-04-01

    This study develops methods to estimate the change in soil characteristics and associated air flow paths in a saturated zone during in situ air sparging. These objectives were achieved by performing combined in situ air sparging and tracer testing, and comparing the breakthrough curves obtained from the tracer gas with those obtained by a numerical simulation model that incorporates a predicted change in porosity that is proportional to the air saturation. The results reveal that revising the porosity and permeability according to the distribution of gas saturation is helpful in breakthrough curve fitting, however, these changes are unable to account for the effects of preferential air flow paths, especially in the zone closest to the points of air injection. It is not known the extent to which these preferential air flow paths were already present versus created, increased, or reduced as a result of the air sparging experiment. The transport of particles from around the sparging well could account for the overall increase in porosity and permeability observed in the study. Collection of soil particles in a monitoring well within 2m of the sparging well provided further evidence of the transport of particles. Transport of particles from near the sparging well also appeared to decrease the radius of influence (ROI). Methods for predicting the effects of pressurized air injection and water flow on the creation or modification of preferential air flow paths are still needed to provide a full description of the change in soil conditions that accompany air sparging.

  3. Metal-air flow batteries using oxygen enriched electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jian-ping; Andrei, Petru; Shellikeri, Annadanesh; Chen, Xujie

    2017-08-01

    A metal air flow battery includes an electrochemical reaction unit and an oxygen exchange unit. The electrochemical reaction unit includes an anode electrode, a cathode electrode, and an ionic conductive membrane between the anode and the cathode, an anode electrolyte, and a cathode electrolyte. The oxygen exchange unit contacts the cathode electrolyte with oxygen separate from the electrochemical reaction unit. At least one pump is provided for pumping cathode electrolyte between the electrochemical reaction unit and the oxygen exchange unit. A method for producing an electrical current is also disclosed.

  4. Influence of Visitors' Flows on Indoor Air Quality of Museum Premises

    Science.gov (United States)

    Dovgaliuk, Volodymyr; Lysak, Pavlo

    2012-06-01

    The article considers the influence of visitors' flows on indoor air quality of museum premises and work of ventilation and air conditioning systems. The article provides the analysis of the heat input from visitors, the results of mathematical simulation of visitors flow influence on indoor air quality. Several advice options are provided on application of variable air volume systems for provision of constant indoor air quality.

  5. Highly deformable nanofilaments in flow

    Science.gov (United States)

    Pawłowska, S.

    2016-10-01

    Experimental analysis of hydrogel nanofilaments conveyed by flow is conducted to help in understanding physical phenomena responsible for transport properties and shape deformations of long bio-objects, like DNA or proteins. Investigated hydrogel nanofilaments exhibit typical macromolecules-like behavior, as spontaneous conformational changes and cross-flow migration. Results of the experiments indicate critical role of thermal fluctuations behavior of single filaments.

  6. Flow Simulation of Solid Rocket Motors. 2; Sub-Scale Air Flow Simulation of Port Flows

    Science.gov (United States)

    Yeh, Y. P.; Ramandran, N.; Smith, A. W.; Heaman, J. P.

    2000-01-01

    The injection-flow issuing from a porous medium in the cold-flow simulation of internal port flows in solid rocket motors is characterized by a spatial instability termed pseudoturbulence that produces a rather non-uniform (lumpy) injection-velocity profile. The objective of this study is to investigate the interaction between the injection- and the developing axial-flows. The findings show that this interaction generally weakens the lumpy injection profile and affects the subsequent development of the axial flow. The injection profile is found to depend on the material characteristics, and the ensuing pseudoturbulence is a function of the injection velocity, the axial position and the distance from the porous wall. The flow transition (from laminar to turbulent) of the axial-flow is accelerated in flows emerging from smaller pores primarily due to the higher pseudoturbulence produced by the smaller pores in comparison to that associated with larger pores. In flows with rather uniform injection-flow profiles (weak or no pseudoturbulence), the axial and transverse velocity components in the porous duct are found to satisfy the sine/cosine analytical solutions derived from inviscid assumptions. The transition results from the present study are compared with previous results from surveyed literature, and detailed flow development measurements are presented in terms of the blowing fraction, and characterizing Reynolds numbers.

  7. Evaporation of polydispersed droplets in a highly turbulent channel flow

    Science.gov (United States)

    Cochet, M.; Bazile, Rudy; Ferret, B.; Cazin, S.

    2009-09-01

    A model experiment for the study of evaporating turbulent two-phase flows is presented here. The study focuses on a situation where pre-atomized and dispersed droplets vaporize and mix in a heated turbulent flow. The test bench consists in a channel flow with characteristics of homogeneous and isotropic turbulence where fluctuations levels reach very high values (25% in the established zone). An ultrasonic atomizer allows the injection of a mist of small droplets of acetone in the carrier flow. The large range diameters ensure that every kind of droplet behavior with regards to turbulence is possible. Instantaneous concentration fields of the vaporized phase are extracted from fluorescent images (PLIF) of the two phase flow. The evolution of the mixing of the acetone vapor is analyzed for two different liquid mass loadings. Despite the high turbulence levels, concentration fluctuations remain significant, indicating that air and acetone vapor are not fully mixed far from the injector.

  8. Evaporation of polydispersed droplets in a highly turbulent channel flow

    Energy Technology Data Exchange (ETDEWEB)

    Cochet, M.; Bazile, Rudy; Ferret, B.; Cazin, S. [INPT, UPS, IMFT (Institut de Mecanique des Fluides de Toulouse), Universite de Toulouse (France)

    2009-09-15

    A model experiment for the study of evaporating turbulent two-phase flows is presented here. The study focuses on a situation where pre-atomized and dispersed droplets vaporize and mix in a heated turbulent flow. The test bench consists in a channel flow with characteristics of homogeneous and isotropic turbulence where fluctuations levels reach very high values (25% in the established zone). An ultrasonic atomizer allows the injection of a mist of small droplets of acetone in the carrier flow. The large range diameters ensure that every kind of droplet behavior with regards to turbulence is possible. Instantaneous concentration fields of the vaporized phase are extracted from fluorescent images (PLIF) of the two phase flow. The evolution of the mixing of the acetone vapor is analyzed for two different liquid mass loadings. Despite the high turbulence levels, concentration fluctuations remain significant, indicating that air and acetone vapor are not fully mixed far from the injector. (orig.)

  9. Quasi-steady-state model of a counter flow air-to-air heat exchanger with phase change

    DEFF Research Database (Denmark)

    Rose, Jørgen; Nielsen, Toke Rammer; Kragh, Jesper;

    2008-01-01

    into account the effects of condensation and frost formation. The model is developed as an Excel spreadsheet, and specific results are compared with laboratory measurements. As an example, the model is used to determine the most energy-efficient control strategy for a specific heat-exchanger under northern......Using mechanical ventilation with highly efficient heat-recovery in northern European or arctic climates is a very efficient way of reducing the energy use for heating in buildings. However, it also presents a series of problems concerning condensation and frost formation in the heat......-exchanger. Developing highly efficient heat-exchangers and strategies to avoid/remove frost formation implies the use of detailed models to predict and evaluate different heat-exchanger designs and strategies. This paper presents a quasi-steady-state model of a counter-flow air-to-air heat-exchanger that takes...

  10. Dimensionless study on outlet flow characteristics of an air-driven booster

    Institute of Scientific and Technical Information of China (English)

    Yan SHI; Mao-lin CAI

    2012-01-01

    Air-driven boosters are widely used to obtain high-pressure gas.Through analysis of the boosting process of an air-driven booster,the basic mathematical model of working processes can be set up.By selecting the appropriate reference values,the basic mathematical model is transformed to a dimensionless expression.Using MATLAB/Simulink for simulation and studying the booster experimentally,the dimensionless outlet flow characteristics of the booster were obtained and the simulation results agree well with the experimental results.Through analysis,it can be seen that the dimensionless outlet flow of the booster is mainly determined by the dimensionless input pressure of the driving chamber,the dimensionless outlet condition pressure of the booster and the dimensionless area of the piston in the driving chamber.The dimensionless average outlet flow becomes larger with an increasing dimensionless input pressure of the driving chamber,but it becomes smaller with an increase in the dimensionless outlet condition pressure of the booster.Especially when the dimensionless outlet condition pressure is approximately 1.4,the dimensionless average outlet flow reaches zero.With an increase in the dimensionless area of the piston in the driving chamber,the dimensionless average outlet flow increases and peaks at approximately 1.89,and after this peak,it starts to decrease.This research can be referred to in the design of air-driven boosters.

  11. Intraoral air pressure and oral air flow under different bleed and bite-block conditions.

    Science.gov (United States)

    Putnam, A H; Shelton, R L; Kastner, C U

    1986-03-01

    Intraoral pressures and oral flows were measured as normal talkers produced /p lambda/ and /si/ under experimental conditions that perturbed the usual aeromechanical production characteristics of the consonants. A translabial pressure-release device was used to bleed off intraoral pressure during /p/. Bite-blocks were used to open the anterior bite artificially during /s/. For /p/, intraoral pressure decreased and translabial air leakage increased as bleed orifice area increased. For /s/, flow increased as the area of sibilant constriction increased, but differential pressure across the /s/ oral constriction did not vary systematically with changes in its area. Flow on postconsonantal vowels /lambda/ and /i/ did not vary systematically across experimental conditions. The data imply that maintenance of perturbed intraoral pressure was more effective when compensatory options included opportunity for increased respiratory drive and structural adjustments at the place of consonant articulation rather than increased respiratory drive alone.

  12. Flow Regimes of Air-Water Counterflow Through Cross Corrugated Parallel Plates

    Energy Technology Data Exchange (ETDEWEB)

    de Almeida, V.F.

    2000-06-07

    Heretofore unknown flow regimes of air-water counterflow through a pair of transparent vertical parallel cross corrugated plates were observed via high-speed video. Air flows upward driven by pressure gradient and water, downward driven by gravity. The crimp geometry of the corrugations was drawn from typical corrugated sheets used as filling material in modern structured packed towers. Four regimes were featured, namely, rivulet, bicontinuous, flooding fronts, and flooding waves. It is conceivable that the regimes observed might constitute the basis for understanding how gas and liquid phases contend for available space in the interstices of structured packings in packed towers. Flow regime transitions were expressed in terms of liquid load (liquid superficial velocity) and gas flow factor parameters commonly used in pressure drop and capacity curves. We have carefully examined the range of parameters equivalent to the ill-understood high-liquid-flow operation in packed towers. More importantly, our findings should prove valuable in validating improved first-principles modeling of gas-liquid flows in these industrially important devices.

  13. 42 CFR 84.148 - Type C supplied-air respirator, continuous flow class; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Type C supplied-air respirator, continuous flow... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.148 Type C supplied-air respirator, continuous flow class; minimum requirements. (a) Respirators tested under this section shall be approved only...

  14. Air flow assisted ionization for remote sampling of ambient mass spectrometry and its application.

    Science.gov (United States)

    He, Jiuming; Tang, Fei; Luo, Zhigang; Chen, Yi; Xu, Jing; Zhang, Ruiping; Wang, Xiaohao; Abliz, Zeper

    2011-04-15

    Ambient ionization methods are an important research area in mass spectrometry (MS) analysis. Under ambient conditions, the gas flow and atmospheric pressure significantly affect the transfer and focusing of ions. The design and implementation of air flow assisted ionization (AFAI) as a novel and effective, remote sampling method for ambient mass spectrometry are described herein. AFAI benefits from a high extracting air flow rate. A systematic investigation of the extracting air flow in the AFAI system has been carried out, and it has been demonstrated not only that it plays a role in the effective capture and remote transport of charged droplets, but also that it promotes desolvation and ion formation, and even prevents ion fragmentation during the ionization process. Moreover, the sensitivity of remote sampling ambient MS analysis was improved significantly by the AFAI method. Highly polar and nonpolar molecules, including dyes, pharmaceutical samples, explosives, drugs of abuse, protein and volatile compounds, have been successfully analyzed using AFAI-MS. The successful application of the technique to residue detection on fingers, large object analysis and remote monitoring in real time indicates its potential for the analysis of a variety of samples, especially large objects. The ability to couple this technique with most commercially available MS instruments with an API interface further enhances its broad applicability.

  15. An evolutionary outlook of air traffic flow management techniques

    Science.gov (United States)

    Kistan, Trevor; Gardi, Alessandro; Sabatini, Roberto; Ramasamy, Subramanian; Batuwangala, Eranga

    2017-01-01

    In recent years Air Traffic Flow Management (ATFM) has become pertinent even in regions without sustained overload conditions caused by dense traffic operations. Increasing traffic volumes in the face of constrained resources has created peak congestion at specific locations and times in many areas of the world. Increased environmental awareness and economic drivers have combined to create a resurgent interest in ATFM as evidenced by a spate of recent ATFM conferences and workshops mediated by official bodies such as ICAO, IATA, CANSO the FAA and Eurocontrol. Significant ATFM acquisitions in the last 5 years include South Africa, Australia and India. Singapore, Thailand and Korea are all expected to procure ATFM systems within a year while China is expected to develop a bespoke system. Asia-Pacific nations are particularly pro-active given the traffic growth projections for the region (by 2050 half of all air traffic will be to, from or within the Asia-Pacific region). National authorities now have access to recently published international standards to guide the development of national and regional operational concepts for ATFM, geared to Communications, Navigation, Surveillance/Air Traffic Management and Avionics (CNS+A) evolutions. This paper critically reviews the field to determine which ATFM research and development efforts hold the best promise for practical technological implementations, offering clear benefits both in terms of enhanced safety and efficiency in times of growing air traffic. An evolutionary approach is adopted starting from an ontology of current ATFM techniques and proceeding to identify the technological and regulatory evolutions required in the future CNS+A context, as the aviation industry moves forward with a clearer understanding of emerging operational needs, the geo-political realities of regional collaboration and the impending needs of global harmonisation.

  16. Compressibility, turbulence and high speed flow

    CERN Document Server

    Gatski, Thomas B

    2013-01-01

    Compressibility, Turbulence and High Speed Flow introduces the reader to the field of compressible turbulence and compressible turbulent flows across a broad speed range, through a unique complimentary treatment of both the theoretical foundations and the measurement and analysis tools currently used. The book provides the reader with the necessary background and current trends in the theoretical and experimental aspects of compressible turbulent flows and compressible turbulence. Detailed derivations of the pertinent equations describing the motion of such turbulent flows is provided and

  17. Measurement and Modelling of Air Flow Rate in a Naturally Ventilated Double Skin Facade

    DEFF Research Database (Denmark)

    Heiselberg, Per; Kalyanova, Olena; Jensen, Rasmus Lund

    2008-01-01

    Air flow rate in a naturally ventilated double skin façade (DSF) is extremely difficult to measure due to the stochastic nature of wind, and as a consequence non-uniform and dynamic flow conditions. This paper describes the results of two different methods to measure the air flow in a full-scale ...

  18. THE PATTERN OF AIR FLOW OUT OF THE MOUTH DURING SPEECH.

    Science.gov (United States)

    LANE, H.; AND OTHERS

    SINCE THE 19TH CENTURY, KYMOGRAPHIC RECORDING OF TOTAL AIR FLOW OUT OF THE MOUTH HAS BEEN USED TO DIAGNOSE THE VARYING DURATIONS AND DEGREES OF CONSTRICTIONS OF THE VOCAL TRACT DURING SPEECH. THE PRESENT PROJECT ATTEMPTS TO INTRODUCE A SECOND DIMENSION TO RECORDINGS OF AIR FLOW OUT OF THE MOUTH--NAMELY, CROSS-SECTIONAL AREA OF FLOW--ON THE…

  19. High strength air-dried aerogels

    Science.gov (United States)

    Coronado, Paul R.; Satcher, Jr., Joe H.

    2012-11-06

    A method for the preparation of high strength air-dried organic aerogels. The method involves the sol-gel polymerization of organic gel precursors, such as resorcinol with formaldehyde (RF) in aqueous solvents with R/C ratios greater than about 1000 and R/F ratios less than about 1:2.1. Using a procedure analogous to the preparation of resorcinol-formaldehyde (RF) aerogels, this approach generates wet gels that can be air dried at ambient temperatures and pressures. The method significantly reduces the time and/or energy required to produce a dried aerogel compared to conventional methods using either supercritical solvent extraction. The air dried gel exhibits typically less than 5% shrinkage.

  20. Magnetic Refrigeration Technology for High Efficiency Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Boeder, A; Zimm, C

    2006-09-30

    Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate

  1. PRINCIPLES OF SAFETY MANAGEMENT OF AIR TRAFFIC FLOWS AND CAPACITY UNDER UNCERTAINTY CONDITIONS

    Directory of Open Access Journals (Sweden)

    Wang Bo

    2016-11-01

    Full Text Available Purpose: The aim of this study is to investigate the general principles of safety and capacity management in Aeronautical systems regarding air traffic flows operations under uncertainty conditions. In this work the theoretical framework assessing at the same time both the uncertainty model and flight plans model are proposed. Methods: To study features of safety of air traffic flows and capacity under uncertainty conditions were built the original probabilistic models including Bayesian Network for flight plan and air traffic control sector model based on Poisson Binomial Distribution. Results: We obtained models for safety management of air traffic flows and capacity under uncertainty conditions. We discussed appropriate approach for estimating the parameters of safety of air traffic flows and capacity under uncertainty and Markovian uncertainty model for the flight plan. Discussion: We developed the Bayesian Network for flight plan and air traffic control sector models for safety management of air traffic flows and capacity under uncertainty conditions.

  2. FLOW CHARACTERISTICS OF WALL-FLOW DIESEL PARTICULATE FILTER SYSTEM WITH REVERSE PULSE AIR REGENERATION

    Institute of Scientific and Technical Information of China (English)

    Yao Chunde; Shao Yuping; Zhang Chunrun; Zi XinYun; Jiang Dahai; Deng Chenglin

    2005-01-01

    To simulate steady airflows inside of wall-flow diesel particulate filters (DPF) with different reverse blowing pipes collocation, a mathematical model of the flow in a DPF is established by an equivalent continuum approach. The experimental results agree well with the theoretical values calculated from the model. Simulation shows that the velocity and the pressure distribution of the filters in the regenerative process are key factors to the filter's regeneration. How to decrease the mal-distribution of the flow in the filter and how to achieve the better regenerative performance at the least cost of air consumption in the regenerative process are the ultimate goals of the study. Calculation and experiments show that the goals can be realized through adjusting the angle of two reverse blowing pipes and their relative location suitably.

  3. Highly stable superhydrophobic surfaces under flow conditions

    Science.gov (United States)

    Lee, Moonchan; Yim, Changyong; Jeon, Sangmin

    2015-01-01

    We synthesized hydrophobic anodic aluminum oxide nanostructures with pore diameters of 35, 50, 65, and 80 nm directly on quartz crystal microresonators, and the stability of the resulting superhydrophobicity was investigated under flow conditions by measuring changes in the resonance frequency and dissipation factor. When the quartz substrates were immersed in water, their hydrophobic surfaces did not wet due to the presence of an air interlayer. The air interlayer was gradually replaced by water over time, which caused decreases in the resonance frequency (i.e., increases in mass) and increases in the dissipation factor (i.e., increases in viscous damping). Although the water contact angles of the nanostructures increased with increasing pore size, the stability of their superhydrophobicity increased with decreasing pore size under both static conditions (without flow) and dynamic conditions (with flow); this increase can be attributed to an increase in the solid surface area that interacts with the air layer above the nanopores as the pore size decreases. Further, the effects of increasing the flow rate on the stability of the superhydrophobicity were quantitatively determined.

  4. Plasma-Assisted Chemistry in High-Speed Flow

    Institute of Scientific and Technical Information of China (English)

    Sergey B.LEONOV; Dmitry A.YARANTSEV; Anatoly P.NAPARTOVICH; Igor V.KOCHETOV

    2007-01-01

    Fundamental problems related to the high-speed combustion are analyzed. The result of plasma-chemical modeling is presented as a motivation of experimental activity.Numerical simulations of the effect of uniform non-equilibrium discharge on the premixed hydrogen and ethylene-air mixture in supersonic flow demonstrate an advantage of such a technique over a heating.Experimental results on multi-electrode non-uniform discharge maintenance behind wallstep and in cavity of supersonic flow are presented.The model test on hydrogen and ethylene ignition is demonstrated at direct fuel injection to low-temperature high-speed airflow.

  5. Flow control of a centrifugal fan in a commercial air conditioner

    Science.gov (United States)

    Kim, Jiyu; Bang, Kyeongtae; Choi, Haecheon; Seo, Eung Ryeol; Kang, Yonghun

    2015-11-01

    Air-conditioning fans require a low noise level to provide user comfort and quietness. The aerodynamic noise sources are generated by highly unsteady, turbulent structures near the fan blade. In this study, we investigate the flow characteristics of a centrifugal fan in an air-conditioner indoor unit and suggest control ideas to develop a low noise fan. The experiment is conducted at the operation condition where the Reynolds number is 163000 based on the blade tip velocity and chord length. Intermittent separation occurs at the blade leading edge and thus flow significantly fluctuates there, whereas vortex shedding occurs at the blade trailing edge. Furthermore, the discharge flow observed in the axial plane near the shroud shows low-frequency intermittent behaviors, resulting in high Reynolds stresses. To control these flow structures, we modify the shapes of the blade leading edge and shroud of the centrifugal fan and obtain noise reduction. The flow characteristics of the base and modified fans will be discussed. Supported by 0420-20130051.

  6. Effect of air-flow on the evaluation of refractive surgery ablation patterns.

    Science.gov (United States)

    Dorronsoro, Carlos; Schumacher, Silvia; Pérez-Merino, Pablo; Siegel, Jan; Mrochen, Michael; Marcos, Susana

    2011-02-28

    An Allegretto Eye-Q laser platform (Wavelight GmbH, Erlangen, Germany) was used to study the effect of air-flow speed on the ablation of artificial polymer corneas used for testing refractive surgery patterns. Flat samples of two materials (PMMA and Filofocon A) were ablated at four different air flow conditions. The shape and profile of the ablated surfaces were measured with a precise non-contact optical surface profilometer. Significant asymmetries in the measured profiles were found when the ablation was performed with the clinical air aspiration system, and also without air flow. Increasing air-flow produced deeper ablations, improved symmetry, and increased the repeatability of the ablation pattern. Shielding of the laser pulse by the plume of smoke during the ablation of plastic samples reduced the central ablation depth by more than 40% with no-air flow, 30% with clinical air aspiration, and 5% with 1.15 m/s air flow. A simple model based on non-inertial dragging of the particles by air flow predicts no central shielding with 2.3 m/s air flow, and accurately predicts (within 2 μm) the decrease of central ablation depth by shielding. The shielding effects for PMMA and Filofocon A were similar despite the differences in the ablation properties of the materials and the different full-shielding transmission coefficient, which is related to the number of particles ejected and their associated optical behavior. Air flow is a key factor in the evaluation of ablation patterns in refractive surgery using plastic models, as significant shielding effects are found with typical air-flow levels used under clinical conditions. Shielding effects can be avoided by tuning the air flow to the laser repetition rate.

  7. 30 CFR 57.22211 - Air flow (I-A mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air flow (I-A mines). 57.22211 Section 57.22211... Methane in Metal and Nonmetal Mines Ventilation § 57.22211 Air flow (I-A mines). The average air velocity... openings nearest the face, shall be at least 40 feet per minute. The velocity of air ventilating each...

  8. Dynamics of Vibration Machine with Air Flow Excitation and Restrictions on Phase Coordinates

    OpenAIRE

    Vība, J; Beresņevičs, V; Štāls, L; Eiduks, M; Kovals, E.; Kruusmaa, M.

    2010-01-01

    The objective of presented article is to show possibilities of practical use of air or liquid flow in vibration engineering. Dynamics of vibration machine with constant air or liquid flow excitation is considered. In the first part vibration motion of the machine working head under constant air or liquid flow velocity excitation is investigated. The main idea is to find out optimal control law for variation of additional surface area of vibrating object within limits. The criterion of optimiz...

  9. Mechanistic understanding of monosaccharide-air flow battery electrochemistry

    Science.gov (United States)

    Scott, Daniel M.; Tsang, Tsz Ho; Chetty, Leticia; Aloi, Sekotilani; Liaw, Bor Yann

    Recently, an inexpensive monosaccharide-air flow battery configuration has been demonstrated to utilize a strong base and a mediator redox dye to harness electrical power from the partial oxidation of glucose. Here the mechanistic understanding of glucose oxidation in this unique glucose-air power source is further explored by acid-base titration experiments, 13C NMR, and comparison of results from chemically different redox mediators (indigo carmine vs. methyl viologen) and sugars (fructose vs. glucose) via studies using electrochemical techniques. Titration results indicate that gluconic acid is the main product of the cell reaction, as supported by evidence in the 13C NMR spectra. Using indigo carmine as the mediator dye and fructose as the energy source, an abiotic cell configuration generates a power density of 1.66 mW cm -2, which is greater than that produced from glucose under similar conditions (ca. 1.28 mW cm -2). A faster transition from fructose into the ene-diol intermediate than from glucose likely contributed to this difference in power density.

  10. Imaging based optofluidic air flow meter with polymer interferometers defined by soft lithography.

    Science.gov (United States)

    Song, Wuzhou; Psaltis, Demetri

    2010-08-02

    We present an optofluidic chip with integrated polymer interferometers for measuring both the microfluidic air pressure and flow rate. The chip contains a microfluidic circuit and optical cavities on a polymer which was defined by soft lithography. The pressure can be read out by imaging the interference patterns of the cavities. The air flow rate was then calculated from the differential pressure across a microfluidic Venturi circuit. Air flow rate measurement in the range of 0-2mg/second was demonstrated. This device provides a simple and versatile way for in situ measuring the microscale air pressure and flow on chip.

  11. High energy hadrons in extensive air showers

    Science.gov (United States)

    Tonwar, S. C.

    1985-01-01

    Experimental data on the high energy hadronic component in extensive air showers of energies approx. 10 to the 14 to 10 to the 16 eV when compared with expectations from Monte Carlo simulations have shown the observed showers to be deficient in high energy hadrons relative to simulated showers. An attempt is made to understand these anomalous features with more accurate comparison of observations with expectations, taking into account the details of the experimental system. Results obtained from this analysis and their implications for the high energy physics of particle interactions at energy approx. 10 to the 15 eV are presented.

  12. Investigating the air oxidation of V(II) ions in a vanadium redox flow battery

    Science.gov (United States)

    Ngamsai, Kittima; Arpornwichanop, Amornchai

    2015-11-01

    The air oxidation of vanadium (V(II)) ions in a negative electrolyte reservoir is a major side reaction in a vanadium redox flow battery (VRB), which leads to electrolyte imbalance and self-discharge of the system during long-term operation. In this study, an 80% charged negative electrolyte solution is employed to investigate the mechanism and influential factors of the reaction in a negative-electrolyte reservoir. The results show that the air oxidation of V(II) ions occurs at the air-electrolyte solution interface area and leads to a concentration gradient of vanadium ions in the electrolyte solution and to the diffusion of V(II) and V(III) ions. The effect of the ratio of the electrolyte volume to the air-electrolyte solution interface area and the concentrations of vanadium and sulfuric acid in an electrolyte solution is investigated. A higher ratio of electrolyte volume to the air-electrolyte solution interface area results in a slower oxidation reaction rate. The high concentrations of vanadium and sulfuric acid solution also retard the air oxidation of V(II) ions. This information can be utilized to design an appropriate electrolyte reservoir for the VRB system and to prepare suitable ingredients for the electrolyte solution.

  13. Design and analysis of Air flow duct for improving the thermal performance of disc brake rotor

    Science.gov (United States)

    Raja, T.; Mathiselvan, G.; Sreenivasulureddy, M.; Goldwin Xavier, X.

    2017-05-01

    safety in automotive engineering has been considered as a number one priority in development of new vehicle. A brake system is one of the most critical systems in the vehicle, without which the vehicle will put a passenger in an unsafe position. Temperature distribution on disc rotor brake and the performance brake of disc rotor is influenced by the air flow around the disc rotor. In this paper, the effect of air flow over the disc rotor is analyzed using the CFD software. The air flow over the disc rotor is increased by using a duct to supply more air flow over the disc rotor. The duct is designed to supply more air to the rotor surface and it can be placed in front of the vehicle for better performance. Increasing the air flow around the rotor will maximize the heat convection from the rotor surface. The rotor life and the performance can be improved.

  14. Liquid Steel at Low Pressure: Experimental Investigation of a Downward Water Air Flow

    Science.gov (United States)

    Thumfart, Maria

    2016-07-01

    In the continuous casting of steel controlling the steel flow rate to the mould is critical because a well-defined flow field at the mould level is essential for a good quality of the cast product. The stopper rod is a commonly used device to control this flow rate. Agglomeration of solid material near the stopper rod can lead to a reduced cross section and thus to a decreased casting speed or even total blockage (“clogging”). The mechanisms causing clogging are still not fully understood. Single phase considerations of the flow in the region of the stopper rod result in a low or even negative pressure at the smallest cross section. This can cause degassing of dissolved gases from the melt, evaporation of alloys and entrainment of air through the porous refractory material. It can be shown that the degassing process in liquid steel is taking place mainly at the stopper rod tip and its surrounding. The steel flow around the stopper rod tip is highly turbulent. In addition refractory material has a low wettability to liquid steel. So the first step to understand the flow situation and transport phenomena which occur near the stopper is to understand the behaviour of this two phase (steel, gas) flow. To simulate the flow situation near the stopper rod tip, water experiments are conducted using a convergent divergent nozzle with three different wall materials and three different contact angles respectively. These experiments show the high impact of the wettability of the wall material on the actual flow structure at a constant gas flow rate.

  15. Numerical Simulation on Flow and Heat Transfer Performance of Air-cooler for a Natural Gas Storage Compressor Unit

    Science.gov (United States)

    Liu, Biyuan; Zhang, Feng; Ma, Zenghui; Zheng, Zilong; Feng, Jianmei

    2017-08-01

    Heat transfer efficiency has been a key issue for large size air coolers with the noise reducers used in natural gas storage compressor unit, especially operated in summer with cooling air at a high temperature. The 3-D numerical simulation model of the whole air cooler was established to study the flow field characteristic with different inlet and outlet structures by CFD software. The system pressure loss distributions were calculated. The relationship was obtained among heat exchange efficiency, resistance loss, and the structure of air cooler, the results presented some methods to improve cooling air flow rate and heat exchange efficiency. Based on the results, some effective measures were proposed to improve heat exchanger efficiency and were implemented in the actual operation unit.

  16. Patterns of a slow air-water flow in a semispherical container

    DEFF Research Database (Denmark)

    Balci, Adnan; Brøns, Morten; Herrada, Miguel A.

    2016-01-01

    This numerical study analyzes the development of eddies in a slow steady axisymmetric air-water flow in a sealed semispherical container, driven by a rotating top disk. As the water height, Hw, increases, new flow cells emerge in both water and air. First, an eddy emerges near the axis-bottom int......This numerical study analyzes the development of eddies in a slow steady axisymmetric air-water flow in a sealed semispherical container, driven by a rotating top disk. As the water height, Hw, increases, new flow cells emerge in both water and air. First, an eddy emerges near the axis...... on the air flow. In contrast to flows in cylindrical and conical containers, there is no interaction with Moffatt corner vortices here....

  17. Pressure drop and heat transfer of a mercury single-phase flow and an air-mercury two-phase flow in a helical tube under a strong magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Minoru E-mail: mtakahas@nr.titech.ac.jp; Momozaki, Yoichi

    2000-11-01

    For the reduction of a large magneto-hydrodynamic (MHD) pressure drop of a liquid metal single-phase flow, a liquid metal two-phase flow cooling system has been proposed. As a fundamental study, MHD pressure drops and heat transfer characteristics of a mercury single-phase flow and an air-mercury two-phase flow were experimentally investigated. A strong transverse magnetic field relevant to the fusion reactor conditions was applied to the mercury single-phase flow and the air-mercury two-phase flow in a helically coiled tube that was inserted in the vertical bore of a solenoidal superconducting magnet. It was found that MHD pressure drops of a mercury single-phase flow in the helically coiled tube were nearly equal to those in a straight tube. The Nusselt number at an outside wall was higher than that at an inside wall both in the mercury single-phase flow in the absence and presence of a magnetic field. The Nusselt number of the mercury single-phase flow decreased, increased and again decreased with an increase in the magnetic flux density. MHD pressure drops did not decrease appreciably by injecting air into a mercury flow and changing the mercury flow into the air-mercury two-phase flow. Remarkable heat transfer enhancement did not appear by the air injection. The injection of air into the mercury flow enhanced heat transfer in the ranges of high mercury flow rate and low magnetic flux density, possibly due to the agitation effect of air bubbles. The air injection deteriorated heat transfer in the range of low mercury flow rates possibly because of the occupation of air near heating wall.

  18. Effects of oscillating air flow on the rheological properties and clearability of mucous gel simulants.

    Science.gov (United States)

    Tomkiewicz, R P; Biviji, A; King, M

    1994-01-01

    This in vitro study addressed the question of clearance-related changes in the physical properties of mucous gel simulants (MGS) subjected to oscillating air flow. Delineating some of the possible mechanisms of action for the reported beneficial effects of high-frequency chest compression (HFCC) therapy constituted the rationale. The rheological variables measured were spinnability by filancemeter and viscoelasticity (mechanical impedance, G*, and loss tangent, tan delta) by magnetic microrheometry. Two derivative parameters, mucociliary clearability index (MCI) and cough clearability index (CCI), were computed from the rheological variables, based on relationships established from model studies of clearance. Two ranges of air flow oscillation frequencies used previously in animal and clinical studies, i.e., 12-13 Hz or 22-23 Hz, were applied. The measurements were made after application of oscillating air flow for 15, 30 and 60 minutes, and compared with those at baseline and negative control. A significant decrease in log G* with administration of oscillations was observed (p = 0.06 at 30 minutes, p < 0.01 at 60 minutes, for G* measured at 1 rad/s). Spinnability also decreased by 19.3% and 30.7% after 15 minutes; 32.9% and 41.1% after 30 minutes; 36.4% and 50.5% after 60 minutes, for 12 Hz and 22 Hz, respectively (all significantly different from baseline). There was a positive correlation between viscoelasticity and spinnability, and a negative correlation between spinnability and CCI, but no correlation between spinnability and MCI. Oscillating air flow seemed to act as a physical "mucolytic" that affected mostly the cough clearability of the mucus simulant.

  19. Dynamic stochastic optimization models for air traffic flow management

    Science.gov (United States)

    Mukherjee, Avijit

    This dissertation presents dynamic stochastic optimization models for Air Traffic Flow Management (ATFM) that enables decisions to adapt to new information on evolving capacities of National Airspace System (NAS) resources. Uncertainty is represented by a set of capacity scenarios, each depicting a particular time-varying capacity profile of NAS resources. We use the concept of a scenario tree in which multiple scenarios are possible initially. Scenarios are eliminated as possibilities in a succession of branching points, until the specific scenario that will be realized on a particular day is known. Thus the scenario tree branching provides updated information on evolving scenarios, and allows ATFM decisions to be re-addressed and revised. First, we propose a dynamic stochastic model for a single airport ground holding problem (SAGHP) that can be used for planning Ground Delay Programs (GDPs) when there is uncertainty about future airport arrival capacities. Ground delays of non-departed flights can be revised based on updated information from scenario tree branching. The problem is formulated so that a wide range of objective functions, including non-linear delay cost functions and functions that reflect equity concerns can be optimized. Furthermore, the model improves on existing practice by ensuring efficient use of available capacity without necessarily exempting long-haul flights. Following this, we present a methodology and optimization models that can be used for decentralized decision making by individual airlines in the GDP planning process, using the solutions from the stochastic dynamic SAGHP. Airlines are allowed to perform cancellations, and re-allocate slots to remaining flights by substitutions. We also present an optimization model that can be used by the FAA, after the airlines perform cancellation and substitutions, to re-utilize vacant arrival slots that are created due to cancellations. Finally, we present three stochastic integer programming

  20. Theoretical study of motion of small spherical air bubbles in a uniform shear flow of water

    Energy Technology Data Exchange (ETDEWEB)

    Mehdi, Syed Murtuza [Mechatronics Engineering, Jeju National University, Jeju (Korea, Republic of); Kim, Sin [School of Energy Systems Engineering, Chung-Ang University, Seoul (Korea, Republic of)

    2015-02-15

    A simple Couette flow velocity profile with an appropriate correlation for the free terminal rise velocity of a single bubble in a quiescent liquid can produce reliable results for the trajectories of small spherical air bubbles in a low-viscosity liquid (water) provided the liquid remains under uniform shear flow. Comparison of the model adopted in this paper with published results has been accomplished. Based on this study it has also been found that the lift coefficient in water is higher than its typical value in a high-viscosity liquid and therefore a modified correlation for the lift coefficient in a uniform shear flow of water within the regime of the Eoetvoes number 0:305 ≤ Eo ≤ 1:22 is also presented.

  1. Effects of Temperature, Humidity and Air Flow on Fungal Growth Rate on Loaded Ventilation Filters.

    Science.gov (United States)

    Tang, W; Kuehn, T H; Simcik, Matt F

    2015-01-01

    This study compares the fungal growth ratio on loaded ventilation filters under various temperature, relative humidity (RH), and air flow conditions in a controlled laboratory setting. A new full-size commercial building ventilation filter was loaded with malt extract nutrients and conidia of Cladosporium sphaerospermum in an ASHRAE Standard 52.2 filter test facility. Small sections cut from this filter were incubated under the following conditions: constant room temperature and a high RH of 97%; sinusoidal temperature (with an amplitude of 10°C, an average of 23°C, and a period of 24 hr) and a mean RH of 97%; room temperature and step changes between 97% and 75% RH, 97% and 43% RH, and 97% and 11% RH every 12 hr. The biomass on the filter sections was measured using both an elution-culture method and by ergosterol assay immediately after loading and every 2 days up to 10 days after loading. Fungal growth was detected earlier using ergosterol content than with the elution-culture method. A student's t-test indicated that Cladosporium sphaerospermum grew better at the constant room temperature condition than at the sinusoidal temperature condition. By part-time exposure to dry environments, the fungal growth was reduced (75% and 43% RH) or even inhibited (11% RH). Additional loaded filters were installed in the wind tunnel at room temperature and an RH greater than 95% under one of two air flow test conditions: continuous air flow or air flow only 9 hr/day with a flow rate of 0.7 m(3)/s (filter media velocity 0.15 m/s). Swab tests and a tease mount method were used to detect fungal growth on the filters at day 0, 5, and 10. Fungal growth was detected for both test conditions, which indicates that when temperature and relative humidity are optimum, controlling the air flow alone cannot prevent fungal growth. In real applications where nutrients are less sufficient than in this laboratory study, fungal growth rate may be reduced under the same operating conditions.

  2. The flow field structure of highly stabilized partially premixed flames in a concentric flow conical nozzle burner with coflow

    KAUST Repository

    Elbaz, Ayman M.

    2015-08-29

    The stability limits, the stabilization mechanism, and the flow field structure of highly stabilized partially premixed methane flames in a concentric flow conical nozzle burner with air co-flow have been investigated and presented in this work. The stability map of partial premixed flames illustrates that the flames are stable between two extinction limits. A low extinction limit when partial premixed flames approach non-premixed flame conditions, and a high extinction limit, with the partial premixed flames approach fully premixed flame conditions. These two limits showed that the most stable flame conditions are achieved at a certain degree of partial premixed. The stability is improved by adding air co-flow. As the air co-flow velocity increases the most stable flames are those that approach fully premixed. The turbulent flow field of three flames at 0, 5, 10 m/s co-flow velocity are investigated using Stereo Particle Image Velocimetry (SPIV) in order to explore the improvement of the flame stability due to the use of air co-flow. The three flames are all at a jet equivalence ratio (Φj) of 2, fixed level of partial premixing and jet Reynolds number (Rej) of 10,000. The use of co-flow results in the formation of two vortices at the cone exit. These vortices act like stabilization anchors for the flames to the nozzle tip. With these vortices in the flow field, the reaction zone shifts toward the reduced turbulence intensity at the nozzle rim of the cone. Interesting information about the structure of the flow field with and without co-flow are identified and reported in this work.

  3. Time-resolved Fast Neutron Radiography of Air-water Two-phase Flows

    Science.gov (United States)

    Zboray, Robert; Dangendorf, Volker; Mor, Ilan; Tittelmeier, Kai; Bromberger, Benjamin; Prasser, Horst-Michael

    Neutron imaging, in general, is a useful technique for visualizing low-Z materials (such as water or plastics) obscured by high-Z materials. However, when significant amounts of both materials are present and full-bodied samples have to be examined, cold and thermal neutrons rapidly reach their applicability limit as the samples become opaque. In such cases one can benefit from the high penetrating power of fast neutrons. In this work we demonstrate the feasibility of time-resolved, fast neutron radiography of generic air-water two-phase flows in a 1.5 cm thick flow channel with Aluminum walls and rectangular cross section. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany. Exposure times down to 3.33 ms have been achieved at reasonable image quality and acceptable motion artifacts. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two-phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured.

  4. KINEMATIC STUDY OF THE AIR FLOW PRODUCED BY SOME SPRAYERS USED IN “TENDONE” VINEYARDS

    Directory of Open Access Journals (Sweden)

    Simone Pascuzzi

    2008-09-01

    Full Text Available A computerized measuring system to analyse the vector field of the air velocities in a volume surrounding the fan of air assisted sprayers usually used in tendone vineyards was designed and built. The performance of three different sprayers was tested: the first, a traditional air-convection sprayer, the other two, suitably designed for treatments in tendone vineyards. The air flow which exited through the discharge diffusers and moving towards the target sucked air from the surrounding environment that enlarged the flow rate on the target. The available flow was that which reached the vegetative and productive area, placed in a horizontal position respectively at 1.8 m and 2.0 m from the ground plane. The pneumatic sprayer produced an air flow clearly directed towards the top of the vines.

  5. Modeling Air Bubble Transport in Hydraulic Jump Flows using Population Balance Approach

    Directory of Open Access Journals (Sweden)

    Min Xiang

    2016-01-01

    Full Text Available This paper proposed a numerical model aiming at coupling the MUltiple-SIze-Group (MUSIG with the semiempirical air entrainment model based on the Euler-Euler two-fluid framework to handle the bubble transport in hydraulic jump flows. The internal flow structure including the recirculation region, the shear layer region and the jet region was accurately predicted. The flow parameters such as the water velocity and void fraction distributions were examined and compared with the experimental data, validating the effectiveness of the numerical model. Prediction of the Sauter mean bubble diameter distributions by the population balance approach at different axial locations confirmed the dominance of breakage due to the high turbulent intensity in the shear layer region which led to the generation of small gas bubbles at high void fraction. Comparison between different cases indicates that high Froude number not only give rise to longer recirculation region and higher void fraction due to larger air entrainment rate, but also generate larger bubble number density and smaller bubble size because of the stronger turbulence intensity in the same axial position.

  6. Influence of the mass flow rate of secondary air on the gas/particle flow characteristics in the near-burner region of a double swirl flow burner

    Energy Technology Data Exchange (ETDEWEB)

    Jing, J.P.; Li, Z.Q.; Wang, L.; Chen, Z.C.; Chen, L.Z.; Zhang, F.C. [Harbin Institute of Technology, Harbin (China)

    2011-06-15

    The influence of the mass flow rate of secondary air on the gas/particle flow characteristics of a double swirl flow burner, in the near-burner region, was measured by a three-component particle-dynamics anemometer, in conjunction with a gas/particle two-phase test facility. Velocities, particle volume flux profiles, and normalized particle number concentrations were obtained. The relationship between the gas/particle flows and the combustion characteristics of the burners was discussed. For different mass flow rates of secondary air, annular recirculation zones formed only in the region of r/d=0.3-0.6 at x/d=0.1-0.3. With an increasing mass flow rate of secondary air, the peaks of the root mean square (RMS) axial fluctuating velocities, radial mean velocities, RMS radial fluctuating velocities, and tangential velocities all increased, while the recirculation increased slightly. There was a low particle volume flux in the central zone of the burner. At x/d=0.1-0.7, the profiles of particle volume flux had two peaks in the secondary air flow zone near the wall. With an increasing mass flow rate of secondary air, the peak of particle volume flux in the secondary air flow zone decreased, but the peak of particle volume flux near the wall increased. In section x/d=0.1-0.5, the particle diameter in the central zone of the burner was always less than the particle diameter at other locations.

  7. Flow measurement in base cooling air passages of a rotating turbine blade

    Science.gov (United States)

    Liebert, C. H.; Pollack, F. G.

    1974-01-01

    The operational performance is decribed of a shaft-mounted system for measuring the air mass flow rate in the base cooling passages of a rotating turbine blade. Shaft speeds of 0 to 9000 rpm, air mass flow rates of 0.0035 to 0.039 kg/sec (0.0077 to 0.085 lbm/sec), and blade air temperatures of 300 to 385 K (80 to 233 F) were measured. Comparisons of individual rotating blade flows and corresponding stationary supply orifice flows agreed to within 10 percent.

  8. Reserve, flowing electrolyte, high rate lithium battery

    Science.gov (United States)

    Puskar, M.; Harris, P.

    Flowing electrolyte Li/SOCl2 tests in single cell and multicell bipolar fixtures have been conducted, and measurements are presented for electrolyte flow rates, inlet and outlet temperatures, fixture temperatures at several points, and the pressure drop across the fixture. Reserve lithium batteries with flowing thionyl-chloride electrolytes are found to be capable of very high energy densities with usable voltages and capacities at current densities as high as 500 mA/sq cm. At this current density, a battery stack 10 inches in diameter is shown to produce over 60 kW of power while maintaining a safe operating temperature.

  9. Electro-Hydrodynamics and Kinetic Modeling of Dry and Humid Air Flows Activated by Corona Discharges

    Science.gov (United States)

    P. Sarrette, J.; Eichwald, O.; Marchal, F.; Ducasse, O.; Yousfi, M.

    2016-05-01

    The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air). The simulation involves the electro-dynamics, chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation. Each discharge lasts about one hundred of a nanosecond while the post-discharge occurring between two successive discharges lasts one hundred of a microsecond. The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO. After 5 ms, the time corresponding to the occurrence of 50 successive discharge/post-discharge phases, a higher NO removal rate and a lower ozone production rate are found in humid air. This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone.

  10. Electro-Hydrodynamics and Kinetic Modeling of Dry and Humid Air Flows Activated by Corona Discharges

    Institute of Scientific and Technical Information of China (English)

    J.P.SARRETTE; O.EICHWALD; F.MARCHAL; O.DUCASSE; M.YOUSFI

    2016-01-01

    The present work is devoted to the 2D simulation of a point-to-plane Atmospheric Corona Discharge Reactor (ACDR) powered by a DC high voltage supply.The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz.The study compares the results obtained in dry air and in air mixed with a small amount of water vapour (humid air).The simulation involves the electro-dynamics,chemical kinetics and neutral gas hydrodynamics phenomena that influence the kinetics of the chemical species transformation.Each discharge lasts about one hundred of a nanosecond while the post-discharge occurring between two successive discharges lasts one hundred of a microsecond.The ACDR is crossed by a lateral dry or humid air flow initially polluted with 400 ppm of NO.After 5 ms,the time corresponding to the occurrence of 50 successive discharge/post-discharge phases,a higher NO removal rate and a lower ozone production rate are found in humid air.This change is due to the presence of the HO2 species formed from the H primary radical in the discharge zone.

  11. Measurement of Air Flow Rate in a Naturally Ventilated Double Skin Facade

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Jensen, Rasmus Lund; Heiselberg, Per

    2007-01-01

    Air flow rate in a naturally ventilated space is extremely difficult to measure due to the stochastic nature of wind, and as a consequence non-uniform and dynamic flow conditions. This paper describes three different methods to measure the air flow in a full-scale outdoor test facility...... with a naturally ventilated double skin façade. In the first method, the air flow in the cavity is estimated on the basis of six measured velocity profiles. The second method is represented by constant injection of tracer gas and in the third method a measured relation in the laboratory is used to estimate...... the flow rate on the basis of continues measurement of the pressure difference between the surface pressure at the opening and inside pressure of the double skin façade. Although all three measurement methods are difficult to use under such dynamic air flow conditions, two of them show reasonable agreement...

  12. Transient flow characteristics of a high speed rotary valve

    Science.gov (United States)

    Browning, Patrick H.

    Pressing economic and environmental concerns related to the performance of fossil fuel burning internal combustion engines have revitalized research in more efficient, cleaner burning combustion methods such as homogeneous charge compression ignition (HCCI). Although many variations of such engines now exist, several limiting factors have restrained the full potential of HCCI. A new method patented by West Virginia University (WVU) called Compression Ignition by Air Injection (CIBAI) may help broaden the range of effective HCCI operation. The CIBAI process is ideally facilitated by operating two synchronized piston-cylinders mounted head-to-head with one of the cylinders filled with a homogeneous mixture of air and fuel and the other cylinder filled with air. A specialized valve called the cylinder connecting valve (CCV) separates the two cylinders, opens just before reaching top dead center (TDC), and allows the injection air into the charge to achieve autoignition. The CCV remains open during the entire power stroke such that upon ignition the rapid pressure rise in the charge cylinder forces mass flow back through the CCV into the air-only cylinder. The limited mass transfer between the cylinders through the CCV limits the theoretical auto ignition timing capabilities and thermal efficiency of the CIBAI cycle. Research has been performed to: (1) Experimentally measure the transient behavior of a potential CCV design during valve opening between two chambers maintained at constant pressure and again at constant volume; (2) Develop a modified theoretical CCV mass flow model based upon the measured cold flow valve performance that is capable of predicting the operating conditions required for successful mixture autoignition; (3) Make recommendations for future CCV designs to maximize CIBAI combustion range. Results indicate that the modified-ball CCV design offers suitable transient flow qualities required for application to the CIBAI concept. Mass injection events

  13. Design and Numerical Simulation on Coupled Flow Field of Radial Turbine with Air-Inlet Volute

    Institute of Scientific and Technical Information of China (English)

    王云飞; 陈焕龙; 陈浮

    2015-01-01

    As one of the core components of turbocharger or micro-turbine, radial turbine has the features of small size and high rotation speed. In order to explore the design method and flow mechanism of the turbine with a volute, a centimeter-scale radial turbine with a vaneless air-inlet volute was designed and simulated numerically to investigate the characteristics of the coupled flow field. The results show that the wheel efficiency of single passage computation without the volute is 80.1%. After accounting for the factors of the loss caused by the volute and the interaction be-tween each passage, the performance is more accurate according to the whole flow passage computation with the vo-lute. High load region gathers at the mid-span and the efficiency declines to 76.6%. The performance of the volute whose structure angle of the trapezoid section is equal to 70 degree is better. Unlike uniform inlet condition in single passage, more appropriate inlet flow for the impeller is provided by the rectification effect of the volute in full passage calculation. Flow parameters are distributed more evenly along the blade span and are generally consistent between each passage at the outlet of the turbine.

  14. Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single Family Homes (Revised)

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, J.; Withers, C.; Martin, E.; Moyer, N.

    2012-10-01

    This document focuses on managing the driving forces which move air and moisture across the building envelope. While other previously published Measure Guidelines focus on elimination of air pathways, the ultimate goal of this Measure Guideline is to manage drivers which cause air flow and water vapor transport across the building envelope (and also within the home), control air infiltration, keep relative humidity (RH) within acceptable limits, avoid combustion safety problems, improve occupant comfort, and reduce house energy use.

  15. Validation of a flow-through sampler for pesticides and polybrominated diphenyl ethers in air

    Science.gov (United States)

    Xiao, Hang; Hung, Hayley; Lei, Ying Duan; Wania, Frank

    At locations without access to the electrical grid, a flow-through sampler (FTS) collects large volumes of air for the analysis of semi-volatile organic compounds (SVOCs). To test its performance under field conditions, an FTS and a traditional pumped high volume air sampler, both using polyurethane foam (PUF) as sampling medium, were co-deployed at the campus of the University of Toronto Scarborough from August 2006 to June 2007. Polybrominated diphenyl ethers (PBDEs) and various pesticides were quantified in the samples taken by both samplers to test the FTS's applicability to relatively non-volatile and slightly polar SVOCs. Air concentrations in samples taken with the FTS over five 2-week periods compare favourably with the average of the concentrations in several 24-h active high volume samples taken during the same period. In particular, time trends, temperature dependence relationships, and isomer ratios show a reasonable agreement between the two sampling techniques. An empirical linear solvation energy relationship for predicting the apparent theoretical plate number of the PUF assembly used in the FTS illustrates the effect of chemical properties, as well as temperature and wind speed, on sampling efficiency. In the absence of electrical power, the FTS can collect SVOCs from large air volumes as reliably and quantitatively as traditional HiVol samplers, although without separating gas and particle phase.

  16. Numerical simulation of air-water two-phase flow over stepped spillways

    Institute of Scientific and Technical Information of China (English)

    CHENG; Xiangju; CHEN; Yongcan

    2006-01-01

    Stepped spillways for significant energy dissipation along the chute have gained interest and popularity among researchers and dam engineers. Due to the complexity of air-water two-phase flow over stepped spillways, the finite volume computational fluid dynamics module of the FLUENT software was used to simulate the main characteristics of the flow. Adopting the RNG k-ε turbulence model, the mixture flow model for air-water two-phase flow was used to simulate the flow field over stepped spillway with the PISO arithmetic technique. The numerical result successfully reproduced the complex flow over a stepped spillway of an experiment case, including the interaction between entrained air bubbles and cavity recirculation in the skimming flow regime, velocity distribution and the pressure profiles on the step surface as well. The result is helpful for understanding the detailed information about energy dissipation over stepped spillways.

  17. Installation of a flow control device in an inclined air-curtain fume hood to control wake-induced exposure.

    Science.gov (United States)

    Chen, Jia-Kun

    2016-08-01

    An inclined plate for flow control was installed at the lower edge of the sash of an inclined air-curtain fume hood to reduce the effects of the wake around a worker standing in front of the fume hood. Flow inside the fume hood is controlled by the inclined air-curtain and deflection plates, thereby forming a quad-vortex flow structure. Controlling the face velocity of the fume hood resulted in convex, straight, concave, and attachment flow profiles in the inclined air-curtain. We used the flow visualization and conducted a tracer gas test with a mannequin to determine the performance of two sash geometries, namely, the half-cylinder and inclined plate designs. When the half-cylinder design was used, the tracer gas test registered a high leakage concentration at Vf ≦ 57.1 fpm or less. This concentration occurred at the top of the sash opening, which was close to the breathing zone of the mannequin placed in front of the fume hood. When the inclined plate design was used, the containment was good, with concentrations of 0.002-0.004 ppm, at Vf ≦ 63.0 fpm. Results indicate that an inclined plate effectively reduces the leakage concentration induced by recirculation flow structures that form in the wake of a worker standing in front of an inclined air-curtain fume hood.

  18. Experimental Validation of Stratified Flow Phenomena, Graphite Oxidation, and Mitigation Strategies of Air Ingress Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Chang Ho Oh; Eung Soo Kim; Hee Cheon No; Nam Zin Cho

    2008-12-01

    The US Department of Energy is performing research and development (R&D) that focuses on key phenomena that are important during challenging scenarios that may occur in the Next Generation Nuclear Plant (NGNP) Program / GEN-IV Very High Temperature Reactor (VHTR). Phenomena identification and ranking studies (PIRT) to date have identified the air ingress event, following on the heels of a VHTR depressurization, as very important (Schultz et al., 2006). Consequently, the development of advanced air ingress-related models and verification and validation (V&V) are very high priority for the NGNP program. Following a loss of coolant and system depressurization, air will enter the core through the break. Air ingress leads to oxidation of the in-core graphite structure and fuel. The oxidation will accelerate heat-up of the bottom reflector and the reactor core and will cause the release of fission products eventually. The potential collapse of the bottom reflector because of burn-off and the release of CO lead to serious safety problems. For estimation of the proper safety margin we need experimental data and tools, including accurate multi-dimensional thermal-hydraulic and reactor physics models, a burn-off model, and a fracture model. We also need to develop effective strategies to mitigate the effects of oxidation. The results from this research will provide crucial inputs to the INL NGNP/VHTR Methods R&D project. This project is focused on (a) analytical and experimental study of air ingress caused by density-driven, stratified, countercurrent flow, (b) advanced graphite oxidation experiments, (c) experimental study of burn-off in the bottom reflector, (d) structural tests of the burnt-off bottom reflector, (e) implementation of advanced models developed during the previous tasks into the GAMMA code, (f) full air ingress and oxidation mitigation analyses, (g) development of core neutronic models, (h) coupling of the core neutronic and thermal hydraulic models, and (i

  19. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  20. Experimental analysis of the velocity field of the air flowing through the swirl diffusers

    Science.gov (United States)

    Jaszczur, M.; Branny, M.; Karch, M.; Borowski, M.

    2016-09-01

    The article presents the results of experimental studies of flow of air through diffusers. Presented laboratory model is a simplification of the real system and was made in a geometric scale 1:10. Simplifying refer both to the geometry of the object and conditions of air flow. The aim of the study is to determine the actual velocity fields of air flowing out of the swirl diffuser. The results obtained for the diffuser various settings are presented. We have tested various flow rates of air. Stereo Particle Image Velocimetry (SPIV) method was used to measure all velocity vector components. The experimental results allow to determine the actual penetration depth of the supply air into the room. This will allow for better definition of the conditions of ventilation in buildings.

  1. Improvement of uniformity in cultivation environment and crop growth rate by hybrid control of air flow devices

    Institute of Scientific and Technical Information of China (English)

    BAEK Min-Seon; KWON Sook-Youn; LIM Jae-Hyun

    2015-01-01

    A complete control type plant factory has high efficiency in terms of cultivation area by constructing vertical multiple layered cultivation beds. However, it has a problem of irregular crop growth due to temperature deviation at upper and lower beds and increases in energy consumption by a prolonged cultivation period. In this work, air flow rate inside a facility was improved by a hybrid control of air flow devices like air conditioning and air circulation fan with an established wireless sensor network to minimize temperature deviations between upper and lower beds and to promote crop growth. The performance of proposed system was verified with an experimental environment or Case A wherein air conditioning device was operated without a control algorithm and Case B wherein air conditioning and circulation fans were alternatively operated based on the hybrid control algorithm. After planting leafy vegetables under each experimental condition, crops were cultivated for 21 days. As a result, Case B wherein AC (air conditioning) and ACF (air-circulation fan) were alternatively operated based on the hybrid control algorithm showed that fresh mass, number of leaves, and leaf length for the crops grown were increased by 40.6%, 41.1%, and 11.1%, respectively, compared to Case A.

  2. Plant pneumatics: stem air flow is related to embolism - new perspectives on methods in plant hydraulics.

    Science.gov (United States)

    Pereira, Luciano; Bittencourt, Paulo R L; Oliveira, Rafael S; Junior, Mauro B M; Barros, Fernanda V; Ribeiro, Rafael V; Mazzafera, Paulo

    2016-07-01

    Wood contains a large amount of air, even in functional xylem. Air embolisms in the xylem affect water transport and can determine plant growth and survival. Embolisms are usually estimated with laborious hydraulic methods, which can be prone to several artefacts. Here, we describe a new method for estimating embolisms that is based on air flow measurements of entire branches. To calculate the amount of air flowing out of the branch, a vacuum was applied to the cut bases of branches under different water potentials. We first investigated the source of air by determining whether it came from inside or outside the branch. Second, we compared embolism curves according to air flow or hydraulic measurements in 15 vessel- and tracheid-bearing species to test the hypothesis that the air flow is related to embolism. Air flow came almost exclusively from air inside the branch during the 2.5-min measurements and was strongly related to embolism. We propose a new embolism measurement method that is simple, effective, rapid and inexpensive, and that allows several measurements on the same branch, thus opening up new possibilities for studying plant hydraulics.

  3. Experimental study on the flow regimes and pressure gradients of air-oil-water three-phase flow in horizontal pipes.

    Science.gov (United States)

    Al-Hadhrami, Luai M; Shaahid, S M; Tunde, Lukman O; Al-Sarkhi, A

    2014-01-01

    An experimental investigation has been carried out to study the flow regimes and pressure gradients of air-oil-water three-phase flows in 2.25 ID horizontal pipe at different flow conditions. The effects of water cuts, liquid and gas velocities on flow patterns and pressure gradients have been studied. The experiments have been conducted at 20 °C using low viscosity Safrasol D80 oil, tap water and air. Superficial water and oil velocities were varied from 0.3 m/s to 3 m/s and air velocity varied from 0.29 m/s to 52.5 m/s to cover wide range of flow patterns. The experiments were performed for 10% to 90% water cuts. The flow patterns were observed and recorded using high speed video camera while the pressure drops were measured using pressure transducers and U-tube manometers. The flow patterns show strong dependence on water fraction, gas velocities, and liquid velocities. The observed flow patterns are stratified (smooth and wavy), elongated bubble, slug, dispersed bubble, and annular flow patterns. The pressure gradients have been found to increase with the increase in gas flow rates. Also, for a given superficial gas velocity, the pressure gradients increased with the increase in the superficial liquid velocity. The pressure gradient first increases and then decreases with increasing water cut. In general, phase inversion was observed with increase in the water cut. The experimental results have been compared with the existing unified Model and a good agreement has been noticed.

  4. Implementation of Models for Building Envelope Air Flow Fields in a Whole Building Hygrothermal Simulation Tool

    DEFF Research Database (Denmark)

    Rode, Carsten; Grau, Karl

    2009-01-01

    Simulation tools are becoming available which predict the heat and moisture conditions in the indoor environment as well as in the envelope of buildings, and thus it has become possible to consider the important interaction between the different components of buildings and the different physical...... phenomena which occur. However, there is still room for further development of such tools. This paper will present an attempt to integrate modelling of air flows in building envelopes into a whole building hygrothermal simulation tool. Two kinds of air flows have been considered: 1. Air flow in ventilated...... cavity such as in the exterior cladding of building envelopes, i.e. a flow which is parallel to the construction plane. 2. Infiltration/exfiltration of air through the building envelope, i.e. a flow which is perpendicular to the construction plane. The new models make it possible to predict the thermal...

  5. Macroscopic Model and Simulation Analysis of Air Traffic Flow in Airport Terminal Area

    Directory of Open Access Journals (Sweden)

    Honghai Zhang

    2014-01-01

    Full Text Available We focus on the spatiotemporal characteristics and their evolvement law of the air traffic flow in airport terminal area to provide scientific basis for optimizing flight control processes and alleviating severe air traffic conditions. Methods in this work combine mathematical derivation and simulation analysis. Based on cell transmission model the macroscopic models of arrival and departure air traffic flow in terminal area are established. Meanwhile, the interrelationship and influential factors of the three characteristic parameters as traffic flux, density, and velocity are presented. Then according to such models, the macro emergence of traffic flow evolution is emulated with the NetLogo simulation platform, and the correlativity of basic traffic flow parameters is deduced and verified by means of sensitivity analysis. The results suggest that there are remarkable relations among the three characteristic parameters of the air traffic flow in terminal area. Moreover, such relationships evolve distinctly with the flight procedures, control separations, and ATC strategies.

  6. High-Throughput Contact Flow Lithography.

    Science.gov (United States)

    Le Goff, Gaelle C; Lee, Jiseok; Gupta, Ankur; Hill, William Adam; Doyle, Patrick S

    2015-10-01

    High-throughput fabrication of graphically encoded hydrogel microparticles is achieved by combining flow contact lithography in a multichannel microfluidic device and a high capacity 25 mm LED UV source. Production rates of chemically homogeneous particles are improved by two orders of magnitude. Additionally, the custom-built contact lithography instrument provides an affordable solution for patterning complex microstructures on surfaces.

  7. Dynamics of autoignitive DME/air coflow flames in oscillating flows

    Science.gov (United States)

    Deng, Sili; Zhao, Peng; Mueller, Michael; Law, Chung

    2016-11-01

    The structure and dynamics of laminar nonpremixed dimethyl ether (DME)/air coflow flames were investigated at elevated temperatures and pressures, conditions at which autoignition times become competitive with flame times. Computations with detailed chemistry were performed for DME and heated coflow air at 30 atm with uniform but sinusoidally oscillating inlet velocities. These unsteady cases were compared with steady flames to elucidate the effect of oscillation frequency on the flame dynamics. In the oscillating reacting flow, periodic but hysteretic transition occurs between a multibrachial autoignition front that locates downstream at high inlet velocity and a tribrachial flame that locates upstream at low inlet velocity. The finite induction time for autoignition results in this hysteretic behavior, which diminishes at lower oscillation frequency as there is more time for chemistry to respond to the hydrodynamic changes and consequently approach steady state.

  8. Relationship between Formation Water Rate, Equivalent Penetration Rate and Volume Flow Rate of Air in Air Drilling

    Institute of Scientific and Technical Information of China (English)

    Wang Kexiong; Zhang Laibin; Jiang Hongwei

    2007-01-01

    Formation water invasion is the most troublesome problem associated with air drilling. However, it is not economical to apply mist drilling when only a small amount of water flows into wellbore from formation during air drilling. Formation water could be circulated out of the wellbore through increasing the gas injection rate. In this paper,the Angel model was modified by introducing Nikurade friction factor for the flow in coarse open holes and translating formation water rate into equivalent penetration rate. Thus the distribution of annular pressure and the relationship between minimum air injection rate and formation water rate were obtained. Real data verification indicated that the modified model is more accurate than the Angel model and can provide useful information for air drilling.

  9. A constant air flow rate control of blower for residential applications

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S.M. [Tamkang Univ., Taipei (Taiwan, Province of China). Dept. of Mechanical Engineering

    1998-03-01

    This paper presents a technique to control a blower for residential applications at constant air flow rate using an induction motor drive. The control scheme combines a variable volt/hertz ratio inverter drive and an average motor current regulation loop to achieve control of the motor torque-speed characteristics, consequently controlling the air flow rate of the blower which the motor is driving. The controller is simple to implement and practical for commercialization. It is also reliable, since no external pressure or air flow sensor is required. Both a theoretical derivation and an experimental verification for the control scheme are presented in this paper.

  10. Flow Analysis By High Speed Photography And Pictures

    Science.gov (United States)

    Werle, H.

    1985-02-01

    At the ONERA hydrodynamic visualization laboratory, high-speed photography and cinematography are used for analysing flow-phenomena around fixed or mobile models in the test section of three vertical water tunnels, operating by gravity draining. These studies in water are based on the hydraulic analogy of aerodynamic incompressible flows. Flow visualization is archieved by liquid tracers (dye emissions) or gaseous tracers (fine air bubbles in suspension in water). In many cases, the pictures at normal speed or long exposure time are insufficient, for they do not permit to distinguish all the details of the phenomena, due to an averaging or motion effect. Furthermore they must be completed with high speed pictures. This is illustrated by a few visua-lization examples recently obtained on following themes - two dimensional flow around a fixed cylinder, first at the start of the flow (symmetrical vortex), then in steady regime (periodic vortex street) ; - laminar-turbulent transition in a boundary layer along a cylindrical body at zero angle of attack ; - flow separation around a sphere and wake in steady regime at small and high Reynolds numbers; - flow separation around a profile, first with fixed incidence, then with harmonic oscillations in pitch ; - core structure of a longitudinal vortex issued from a wing first organized, then disintegrated under the effect of a lengthwise pressure gradient (vortex breakdown) ; - mixing zone around a turbulent axisymmetric jet, characterized by the formation of large vortex struc-tures ; - hovering tests of an helicopter rotor, first at the start of the rotation, then in established regime, finally in cruise flight ; - case of a complete helicopter model in cruise-flight, with air-intake simulation, gas exhaust and tail rotor ; - flow around a complete delta-wing aircraft model at mean or high angle of attack, first in steady regime, then with harmonic oscillations in yaw or pitch. These results illustrate the contribution of

  11. Characterization of non equilibrium effects on high quality critical flows

    Energy Technology Data Exchange (ETDEWEB)

    Camelo, E.; Lemonnier, H.; Ochterbeck, J. [Commissariat a l Energie Atomique, Grenoble (France)] [and others

    1995-09-01

    The appropriate design of various pieces of safety equipment such as relief systems, relies on the accurate description of critical flow phenomena. Most of the systems of industrial interest are willing to be described by one-dimensional area-averaged models and a large fraction of them involves multi-component high gas quality flows. Within these circumstances, the flow is very likely to be of an annular dispersed nature and its description by two-fluid models requires various closure relations. Among the most sensitive closures, there is the interfacial area and the liquid entrained fraction. The critical flowrate depends tremendously on the accurate description of the non equilibrium which results from the correctness of the closure equations. In this study, two-component flows are emphasized and non equilibrium results mainly form the differences in the phase velocities. It is therefore of the utmost importance to have reliable data to characterize non equilibrium phenomena and to assess the validity of the closure models. A comprehensive description of air-water nozzle flows, with emphasis on the effect of the nozzle geometry, has been undertaken and some of the results are presented here which helps understanding the overall flow dynamics. Besides the critical flowrate, the presented material includes pressure profiles, droplet size and velocity, liquid film flowrate and liquid film thickness.

  12. Turbulent Poiseuille & Couette flows at high Re

    Science.gov (United States)

    Lee, Myoungkyu; Moser, Robert D.

    2016-11-01

    We present the results of direct numerical simulation (DNS) of high Re turbulent Poiseuille and Couette flows. Couette flow has been simulated with a streamwise (x) domain that is 100 πδ long at Reynolds number up to Reτ 500 . In addition Poiseuille flow simulations up to Reτ 5200 were performed. In Couette flow, extremely large scale motions, which are approximately 50 πδ long in the x-direction with very strong intensity, have been observed. In this presentation we will focus on a comparison between these two flows in terms of the vorticity-velocity co-spectra, which are interesting because of the relationship between the Reynolds stress and the velocity-vorticity correlation (∂y = - ). Also considered will be the spectra of the turbulent transport term in the evolution equation for the turbulent kinetic energy. In both (co)-spectra it is shown that the difference between the two flows at high Re are primarily at large scales. This work was supported by NSF (OCI-0749223 and PRAC Grant 0832634), and computation resources were provided by the Argonne Leadership Computing Facility through the Early Science, INCITE 2013 and Directors Discretionary Programs.

  13. Chaotic behaviour of high Mach number flows

    Science.gov (United States)

    Varvoglis, H.; Ghosh, S.

    1985-01-01

    The stability of the super-Alfvenic flow of a two-fluid plasma model with respect to the Mach number and the angle between the flow direction and the magnetic field is investigated. It is found that, in general, a large scale chaotic region develops around the initial equilibrium of the laminar flow when the Mach number exceeds a certain threshold value. After reaching a maximum the size of this region begins shrinking and goes to zero as the Mach number tends to infinity. As a result high Mach number flows in time independent astrophysical plasmas may lead to the formation of 'quasi-shocks' in the presence of little or no dissipation.

  14. 42 CFR 84.155 - Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE supplied-air respirator; minimum requirements. 84.155 Section... CE supplied-air respirator; minimum requirements. The resistance to air flowing from the respirator...

  15. Controlling the dispersion and configuration of nanofillers in electrically driven polymer jets with and without air flow

    Science.gov (United States)

    Zhmayev, Yevgen; Joo, Yong; Park, Jay; Fei, Ling; Kaur, Prabhleen; Liu, Hongshen

    2015-03-01

    Controlling the dispersion of nanofillers in polymer matrices has a significant effect on their properties. Employing circumferentially uniform air flow through the sheath layer of the concentric coaxial nozzle, the gas-assisted electrospinning utilizes both high electric field and controlled air flow which can offer i) enhanced stretching of fluid jet and thus much higher throughput and thinner fibers, and ii) better control of dispersion and configuration of nanofillers in a polymer matrix even at high loadings. The ability to tailor the distribution of various nanofillers (1.85-12.92 vol. % of spherical SiO2\\ and Si nanoparticles and rod/tube-like carbon nanotubes and carbon nanoribbons) in a polyvinyl alcohol (PVA) jet was demonstrated by varying electric potentials in conventional electrospinning and air flow rates in gas-assisted electrospinning. The distribution of nanofillers in nanofibers was measured by transmission electron microscopy (TEM), and analyzed using an image processing software to obtain concentration profiles. By increasing the electric potential in conventional electrospinning from 80 to 125 kV/m, we observed almost a twofold improvement in NP distribution. The further enhancement of nanoparticle dispersion was observed in gas-assisted electrospinning: Our analysis indicated an additional 70 percent improvement with the application of high, but controlled air flow. Lastly, the enhanced performance by the resulting nanofibers with controlled nanofiller dispersion will also be addressed in Li-ion battery anode applications. Axium battery, AZ Electronic Materials.

  16. LABORATORY EVALUATION OF AIR FLOW MEASUREMENT METHODS FOR RESIDENTIAL HVAC RETURNS

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain; Stratton, Chris

    2015-02-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  17. Analysis of electrode system for generation of high-power electrodynamic flow

    Science.gov (United States)

    Rebrov, I. E.; Khomich, V. Yu.; Yamshchikov, V. A.

    2016-08-01

    A high-power electrodynamic flow in atmospheric air is numerically simulated and experimentally studied. An electrode system consisting of a cylindrical plasma emitter and a plane metal grid collector of ions is used to generate a flow with a speed of 2 m/s and a volume rate of 15 L/s.

  18. EXPERIMENTAL INVESTIGATION ON SOUND SPEED PROPAGATING THROUGH HIGH SPEED AERATED FLOW IN OPEN CHANNEL

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    An experiment concerning the sound propaga-tion in aerated open channel flow was designed and conductedin a variable slope chute. The acquisition of sound data wasdone by the hydro-phones installed into the bottom wall of thechute. The data were analyzed and processed by the tape re-corder and a 3562A analyzer. The primary experimetal resultsindicated that the sound speed in aerated flow is varied with the air concentration and highly lower than each of the soundspeed in pure water or air. As released by the derived theoryformula, the minimum sound of 24m/s in aerated flow hap-pened when the air concentration achieved to 50%. This resultshows that the compressibility of high speed aerated flowshould be considered when the air concentration is near to50%. A criterion of compressibility of high speed aerated flowwas also giv. En in this paper.

  19. Numerical Simulation of the Air Jet Flow Field in the Melt Blowing Process

    Institute of Scientific and Technical Information of China (English)

    CHEN Ting; HUANG Xiu-bao

    2002-01-01

    The theoretical model of the flow field of the dual slot die in melt blowing process is founded. The model is solved numerically with finite difference method. The distributions of the air velocity component in x direction along x-axis and y-axis and the air temperature distributions along x-axis and y-axis are obtained via numerical computation. The computation results coincide with the experimental data given by Harpham and Shambaugh. The distributions of the air velocity and air temperature are introduced into the air drag model of melt blowing. The model prediction of the fiber diameter agrees with the experimental data well.

  20. Transient Flow in Rapidly Filling Air-Entrapped Pipelines with Moving Boundaries

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yongliang; K. Vairavamoorthy

    2006-01-01

    A mathematical model is presented for transient flow in a rapidly filling pipeline with an entrapped air pocket. The influence of transient shear stress between the pipe wall and the flowing fluid is taken into account. A coordinate transformation technique is employed to generate adaptive moving meshes for the multiphase flow system as images of the time-independent computational meshes in auxiliary domains. The method of characteristics is used to reduce the coupled nonlinear hyperbolic partial differential equations governing the motion of the filling fluid, entrapped air, and blocking fluid to ordinary differential equations.Numerical solution of resulting equations shows that the transient shear stresses have only a small damping effect on the pressure fluctuations. The peak pressure in the entrapped air pocket decreases significantly with increasing initial entrapped air volume, but decreases slightly with increasing initial entrapped air pressure.

  1. Hydraulic Resistance and Liberation of Air in Aviation Kerosene Flow Through Diaphragms at Low Pressure

    Science.gov (United States)

    Kitanin, É. L.; Kitanina, E. É.; Zherebtsov, V. A.; Peganova, M. M.; Stepanov, S. G.; Bondarenko, D. A.; Morisson, D.

    2016-09-01

    This paper presents the results of experimental investigations of the liberation of air in gravity flow of aviation fuel through a pipeline with diaphragms. Experiments were carried out in the pressure range 0.2-1.0 bar and temperature range -20 to +20°C. The TC-1 kerosene was preliminarily saturated with air at atmospheric pressure. The liberation of air after the diaphragms with three ratios of the flow area to the cross-sectional area of the pipeline has been investigated. The results of investigations of the two-phase flow in several experimental pipelines containing one or two diaphragms and other local hydraulic resistances have been generalized. The obtained approximation equations permit calculating the hydraulic resistance of the diaphragm in the two-phase flow and the mass gas content of air after the diaphragm in pipelines of complex geometry.

  2. Mitigate Strategy of Very High Temperature Reactor Air-ingress Accident

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Tae Kyu [KHNP CRI, Daejeon (Korea, Republic of); Arcilesi, David J.; Sun, Xiaodong; Christensen, Richard N. [The Ohio State University, Columbus (United States); Oh, Chang H.; Kim, Eung S. [Idaho National Laboratory, Idaho (United States)

    2016-10-15

    A critical safety event of the Very High Temperature Reactor (VHTR) is a loss-of-coolant accident (LOCA). Since a VHTR uses graphite as a core structure, if there is a break on the pressure vessel, the air in the reactor cavity could ingress into the reactor core. The worst case scenario of the accident is initiated by a double-ended guillotine break of the cross vessel that connects the reactor vessel and the power conversion unit. The operating pressures in the vessel and containment are about 7 and 0.1 MPa, respectively. In the VHTR, the reactor pressure vessel is located within a reactor cavity which is filled with air during normal operation. Therefore, the air-helium mixture in the cavity may ingress into the reactor pressure vessel after the depressurization process. In this paper, a commercial computational fluid dynamics (CFD) tool, FLUENT, was used to figure out air-ingress mitigation strategies in the gas-turbine modular helium reactor (GT-MHR) designed by General Atomics, Inc. After depressurization, there is almost no air in the reactor cavity; however, the air could flow back to the reactor cavity since the reactor cavity is placed in the lowest place in the reactor building. The heavier air could flow to the reactor cavity through free surface areas in the reactor building. Therefore, Argon gas injection in the reactor cavity is introduced. The injected argon would prevent the flow by pressurizing the reactor cavity initially, and eventually it prevents the flow by making the gas a heavier density than air in the reactor cavity. The gate opens when the reactor cavity is pressurized during the depressurization and it closes by gravity when the depressurization is terminated so that it can slow down the air flow to the reactor cavity.

  3. Numerical Model of Air Valve For Computation of One-dimensional Flow

    Directory of Open Access Journals (Sweden)

    Daniel HIMR

    2014-06-01

    Full Text Available The paper is focused on a numerical simulation of unsteady flow in a pipeline. The special attention is paid to a numerical model of an air valve, which has to include all possible regimes: critical/subcritical inflow and critical/subcritical outflow of air. Thermodynamic equation of subcritical mass flow was simplified to get more friendly shape of relevant equations, which enables easier solution of the problem.

  4. Bioinspired carbon nanotube fuzzy fiber hair sensor for air-flow detection.

    Science.gov (United States)

    Maschmann, Matthew R; Ehlert, Gregory J; Dickinson, Benjamin T; Phillips, David M; Ray, Cody W; Reich, Greg W; Baur, Jeffery W

    2014-05-28

    Artificial hair sensors consisting of a piezoresistive carbon-nanotube-coated glass fiber embedded in a microcapillary are assembled and characterized. Individual sensors resemble a hair plug that may be integrated in a wide range of host materials. The sensors demonstrate an air-flow detection threshold of less than 1 m/s with a piezoresistive sensitivity of 1.3% per m/s air-flow change.

  5. The influence of air flow speed on fire propagation in object

    Directory of Open Access Journals (Sweden)

    Jevtić Radoje

    2015-01-01

    Full Text Available Fire presents the process of the uncontrolled combustion that makes material damage and endangers human lives. It is important to know the factors that fire depends on for success projecting and realization of fire protection systems. One of such factors is different air flow that could be presented as wind, draft and the like. The simulation of different air flow speeds and its influences on fire propagation in object were analyzed in this paper.

  6. Define and Quantify the Physics of Air Flow, Pressure Drop and Aerosol Collection in Nuclear Grade HEPA Filters

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Murray E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-02-23

    Objective: Develop a set of peer-review and verified analytical methods to adjust HEPA filter performance to different flow rates, temperatures and altitudes. Experimental testing will measure HEPA filter flow rate, pressure drop and efficiency to verify the analytical approach. Nuclear facilities utilize HEPA (High Efficiency Particulate Air) filters to purify air flow for workspace ventilation. However, the ASME AG-1 technical standard (Code on Nuclear Air and Gas Treatment) does not adequately describe air flow measurement units for HEPA filter systems. Specifically, the AG-1 standard does not differentiate between volumetric air flow in ACFM (actual cubic feet per minute)compared to mass flow measured in SCFM (standard cubic feet per minute). More importantly, the AG-1 standard has an overall deficiency for using HEPA filter devices at different air flow rates, temperatures, and altitudes. Technical Approach: The collection efficiency and pressure drops of 18 different HEPA filters will be measured over a range of flow rates, temperatures and altitudes. The experimental results will be compared to analytical scoping calculations. Three manufacturers have allocated six HEPA filters each for this effort. The 18 filters will be tested at two different flow rates, two different temperatures and two different altitudes. The 36 total tests will be conducted at two different facilities: the ATI Test facilities (Baltimore MD) and the Los Alamos National Laboratory (Los Alamos NM). The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally designed to evaluate small air samplers. In 2010, modifications were started to convert the wind tunnel for HEPA filter testing. (Extensive changes were necessary for the required aerosol generators, HEPA test fixtures, temperature control devices and measurement capabilities.) To this date, none of these modification activities have been funded through a specific DOE or NNSA program. This is

  7. Discharge flow of granular media from silos with a lateral orifice and injection of air

    Directory of Open Access Journals (Sweden)

    Aussillous Pascale

    2017-01-01

    Full Text Available Few studies concern the prediction of the mass flow rate of a granular media discharged from a silo with a lateral orifice. However, this situation can have pratical interest considering a tank of granular material with a leak on its side. We studied experimentally the discharge of a vertical silo filled by spherical glass beads. We consider rectangular silos with a rectangular orifice. The impact of size, aspect ratio and position of the orifice and the effect of an additional air flow were studied. The measured parameters are the mass flow rate and the pressure along the silo, whereas the controlled parameters are the size of particles, and the flow rate of air. We identified two regimes of discharge according to the aspect ratio (of width to height of the rectangular orifice. Increasing the air flow rate induces an increase of the granular media flow rate. Using a simple physical model to describe the grains and gas flow, we put in evidence the role played by the air pressure gradient at the outlet. Then we compared the experimental results with continuum Navier-Stokes simulations with the granular μ(I-rheology. We showed that the continuum μ(I-rheology describes well our discharge flow of granular media from silos, taking into account the effect of the position of the orifice as well as the coupling with the gas flow.

  8. Modeling the Air Flow in the 3410 Building Filtered Exhaust Stack System

    Energy Technology Data Exchange (ETDEWEB)

    Recknagle, Kurtis P.; Barnett, J. Matthew; Suffield, Sarah R.

    2013-01-23

    Additional ventilation capacity has been designed for the 3410 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and will include ductwork to incorporate the new fan into the existing stack. Stack operations will involve running various two-fan combinations at any given time. The air monitoring system of the existing two-fan stack was previously found to be in compliance with the ANSI/HPS N13.1-1999 standard, however it is not known if the modified (three-fan) system will comply. Subsequently, a full-scale three-dimensional (3-D) computational fluid dynamics (CFD) model of the modified stack system has been created to examine the sampling location for compliance with the standard. The CFD modeling results show good agreement with testing data collected from the existing 3410 Building stack and suggest that velocity uniformity and flow angles will remain well within acceptance criteria when the third fan and associated ductwork is installed. This includes two-fan flow rates up to 31,840 cfm for any of the two-fan combinations. For simulation cases in which tracer gas and particles are introduced in the main duct, the model predicts that both particle and tracer gas coefficients of variance (COVs) may be larger than the acceptable 20 percent criterion of the ANSI/HPS N13.1-1999 standard for each of the two-fan, 31,840 cfm combinations. Simulations in which the tracers are introduced near the fans result in improved, though marginally acceptable, COV values for the tracers. Due to the remaining uncertainty that the stack will qualify with the addition of the third fan and high flow rates, a stationary air blender from Blender Products, Inc. is considered for inclusion in the stack system. A model of the air blender has been developed and incorporated into the CFD model. Simulation results from the CFD model that includes the air blender show striking improvements in tracer gas mixing and tracer particle

  9. Modelling of the flow of stable air over a complex region

    CSIR Research Space (South Africa)

    Scholtz, MT

    1976-01-01

    Full Text Available The flow of stable air over a general region of complex topography and non-uniform surface temperature has been investigated. In order to gain further understanding of the motion of surface air, it was necessary to study the vertical structure...

  10. Measurement of the resistivity of porous materials with an alternating air-flow method.

    Science.gov (United States)

    Dragonetti, Raffaele; Ianniello, Carmine; Romano, Rosario A

    2011-02-01

    Air-flow resistivity is a main parameter governing the acoustic behavior of porous materials for sound absorption. The international standard ISO 9053 specifies two different methods to measure the air-flow resistivity, namely a steady-state air-flow method and an alternating air-flow method. The latter is realized by the measurement of the sound pressure at 2 Hz in a small rigid volume closed partially by the test sample. This cavity is excited with a known volume-velocity sound source implemented often with a motor-driven piston oscillating with prescribed area and displacement magnitude. Measurements at 2 Hz require special instrumentation and care. The authors suggest an alternating air-flow method based on the ratio of sound pressures measured at frequencies higher than 2 Hz inside two cavities coupled through a conventional loudspeaker. The basic method showed that the imaginary part of the sound pressure ratio is useful for the evaluation of the air-flow resistance. Criteria are discussed about the choice of a frequency range suitable to perform simplified calculations with respect to the basic method. These criteria depend on the sample thickness, its nonacoustic parameters, and the measurement apparatus as well. The proposed measurement method was tested successfully with various types of acoustic materials.

  11. Improving flow and spillage characteristics of range hoods by using an inclined air-curtain technique.

    Science.gov (United States)

    Huang, Rong Fung; Nian, You-Cyun; Chen, Jia-Kun; Peng, Kuan-Lin

    2011-03-01

    The current study developed a new type of range hood, which was termed an 'inclined air-curtain range hood', in order to improve the flow and performance of the conventionally used wall-mounted range hood. The flow characteristics and oil mist spillages of air-curtain and conventional range hoods under the influences of both a mannequin presence and a simulated walk-by motion were experimentally examined. The study examined flow patterns by using a laser-light-sheet-assisted smoke-flow visualization technique and diagnosed spillages by using the tracer gas concentration test method. A mannequin presented in front of the conventional hood induced turbulent dispersion of oil mists toward the chest and nose of the mannequin owing to the complex interaction among the suction, wake, and wall effect, while the inclined air-curtain hood presented excellent hood performance by isolating the oil mists from the mannequin with an air curtain and therefore could reduce spillages out into the atmosphere and the mannequin's breathing zone. Both flow visualization and the tracer gas test indicated that the air-curtain hood had excellent 'robustness' over the conventional hood in resisting the influence of walk-by motion. The air-curtain technique could drastically improve the flow characteristics and performance of the range hood by consuming less energy.

  12. Impingement heat sinks for air cooled high power electronic modules

    Energy Technology Data Exchange (ETDEWEB)

    Kang, S.S.; Holahan, M.F. [IBM Corp., Rochester, MN (United States)

    1995-12-31

    The subject of the present work is a parallel plate heat sink that is designed so that the air flow impinges at the fin tips and exhausts over the two open side faces. This type of design attempts to achieve an air flow direction that is substantially opposite to the heat flow direction within the fins so as to exploit the greater heat transfer effectiveness of counterflow heat exchange. A one dimensional model of the heat sink was developed with the assumption of air flow from the fin tips to the fin base. This simplified model was used to identify an initial heat sink geometry to cool a specific multichip module. Computational Fluid Dynamics models that account for the actual flow pattern within the heat sink were used to study a range of variations to the initial geometry and to identify the best geometry over the range examined. Experimental heat transfer and pressure drop data is reported for two heat sink prototypes. The test data is in good agreement with CFD predictions. Suitable correlations for the heat sink thermal resistance and pressure drop versus the air flow rate are developed. The developed heat sink demonstrated an area specific thermal resistance better than 8.7 C (W/cm{sup 2}).

  13. Experimental study on two-phase flow natural circulation in a core catcher cooling channel for EU-APR1400 using air-water system

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ki Won [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon 34057 (Korea, Republic of); Nguyen, Thanh Hung [School of Nuclear Engineering, Purdue University, West Lafayette, IN 47906 (United States); Ha, Kwang Soon; Kim, Hwan Yeol; Song, Jinho [Korea Atomic Energy Research Institute, Daejeon 34057 (Korea, Republic of); Park, Hyun Sun [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Revankar, Shripad T., E-mail: shripad@postech.ac.kr [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); School of Nuclear Engineering, Purdue University, West Lafayette, IN 47906 (United States); Kim, Moo Hwan [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Korea Institute of Nuclear Safety, Daejeon 305-338 (Korea, Republic of)

    2017-05-15

    Highlights: • Two-phase flow regimes and transition behavior were observed in the coolant channel. • Test were conducted for natural circulation with air-water. • Data were obtained on flow regime, void fraction, flow rates and re-wetting time. • The data were related to a cooling capability of core catcher system. - Abstract: Ex-vessel core catcher cooling system driven by natural circulation is designed using a full scaled air-water system. A transparent half symmetric section of a core catcher coolant channel of a pressurized water reactor was designed with instrumentations for local void fraction measurement and flow visualization. Two designs of air-water top separator water tanks are studied including one with modified ‘super-step’ design which prevents gas entrainment into down-comer. In the experiment air flow rates are set corresponding to steam generation rate for given corium decay power. Measurements of natural circulation flow rate, spatial local void fraction distribution and re-wetting time near the top wall are carried out for various air flow rates which simulate boiling-induced vapor generation. Since heat transfer and critical heat flux are strongly dependent on the water mass flow rate and development of two-phase flow on the heated wall, knowledge of two-phase flow characteristics in the coolant channel is essential. Results on flow visualization showing two phase flow structure specifically near the high void accumulation regions, local void profiles, rewetting time, and natural circulation flow rate are presented for various air flow rates that simulate corium power levels. The data are useful in assessing the cooling capability of and safety of the core catcher system.

  14. Engineering Model of High Pressure Moist Air

    Directory of Open Access Journals (Sweden)

    Hyhlík Tomáš

    2017-01-01

    Full Text Available The article deals with the moist air equation of state. There are equations of state discussed in the article, i.e. the model of an ideal mixture of ideal gases, the model of an ideal mixture of real gases and the model based on the virial equation of state. The evaluation of sound speed based on the ideal mixture concept is mentioned. The sound speed calculated by the model of an ideal mixture of ideal gases is compared with the sound speed calculated by using the model based on the concept of an ideal mixture of real gases. The comparison of enthalpy end entropy based on the model of an ideal mixture of ideal gases and the model of an ideal mixture of real gases is performed. It is shown that the model of an ideal mixture of real gases deviates from the model of an ideal mixture of ideal gases only in the case of high pressure. An impossibility of the definition of partial pressure in the mixture of real gases is discussed, where the virial equation of state is used.

  15. Negative DC corona discharge current characteristics in a flowing two-phase (air + suspended smoke particles) fluid

    Science.gov (United States)

    Berendt, Artur; Domaszka, Magdalena; Mizeraczyk, Jerzy

    2017-04-01

    The electrical characteristics of a steady-state negative DC corona discharge in a two-phase fluid (air with suspended cigarette smoke particles) flowing along a chamber with a needle-to-plate electrode arrangement were experimentally investigated. The two-phase flow was transverse in respect to the needle-to-plate axis. The velocity of the transverse two-phase flow was limited to 0.8 m/s, typical of the electrostatic precipitators. We found that three discharge current modes of the negative corona exist in the two-phase (air + smoke particles) fluid: the Trichel pulses mode, the "Trichel pulses superimposed on DC component" mode and the DC component mode, similarly as in the corona discharge in air (a single-phase fluid). The shape of Trichel pulses in the air + suspended particles fluid is similar to that in air. However, the Trichel pulse amplitudes are higher than those in "pure" air while their repetition frequency is lower. As a net consequence of that the averaged corona discharge current in the two-phase fluid is lower than in "pure" air. It was also found that the average discharge current decreases with increasing suspended particle concentration. The calculations showed that the dependence of the average negative corona current (which is a macroscopic corona discharge parameter) on the particle concentration can be explained by the particle-concentration dependencies of the electric charge of Trichel pulse and the repetition frequency of Trichel pulses, both giving a microscopic insight into the electrical phenomena in the negative corona discharge. Our investigations showed also that the average corona discharge current in the two-phase fluid is almost unaffected by the transverse fluid flow up to a velocity of 0.8 m/s. Contribution to the topical issue "The 15th International Symposium on High Pressure Low Temperature Plasma Chemistry (HAKONE XV)", edited by Nicolas Gherardi and Tomáš Hoder

  16. Active flow control integrated diffuser (afcid) for increased energy efficiency in variable air volume systems

    Science.gov (United States)

    Van Der Schijff, Hermanus P.

    Variable air volume (VAV) air terminals are designed to save energy by reducing airflow into a given space based on occupancy and required load. Systems are typically designed to operate at peak load, however as load is reduced, performance is compromised due to inadequate throw. As a result, fans are installed to adjust for the losses, negating many of the energy savings. Additionally flow is vectored by the use of vanes, a basic passive type of flow control. An experimental investigation was performed to study the application of flow control on that of a HVAC diffuser using synthetic jets distributed evenly along the diffuser edge parallel to the flow field. The study was conducted on a 1:3 scale typical office space (150 ft2), which included a simulated scale HVAC system supplied by compressed air. Two different jet blowing ratios were investigated for system loads of 60% and 90%. The flow field was established using hot wire anemometry and Particle Image Velocimetry (PIV). This study demonstrates the effectiveness of synthetic jet based active flow control at controlling airflow, showing ability to affect throw parameters for changing flow rates within the test chamber. Vectoring of up to 20% and improvement in jet spread of 200% was demonstrated. The use of such devices has the potential to improve air quality and air distribution in building while simultaneously lowering energy demands of HVAC systems.

  17. Experimental and computational study and development of the bituminous coal entrained-flow air-blown gasifier for IGCC

    Science.gov (United States)

    Abaimov, N. A.; Osipov, P. V.; Ryzhkov, A. F.

    2016-10-01

    In the paper the development of the advanced bituminous coal entrained-flow air- blown gasifier for the high power integrated gasification combined cycle is considered. The computational fluid dynamics technique is used as the basic development tool. The experiment on the pressurized entrained-flow gasifier was performed by “NPO CKTI” JSC for the thermochemical processes submodel verification. The kinetic constants for Kuznetsk bituminous coal (flame coal), obtained by thermal gravimetric analysis method, are used in the model. The calculation results obtained by the CFD model are in satisfactory agreements with experimental data. On the basis of the verified model the advanced gasifier structure was suggested which permits to increase the hydrogen content in the synthesis gas and consequently to improve the gas turbine efficiency. In order to meet the specified requirements vapor is added on the second stage of MHI type gasifier and heat necessary for air gasification is compensated by supplemental heating of the blasting air.

  18. Ignition of an organic water-coal fuel droplet floating in a heated-air flow

    Science.gov (United States)

    Valiullin, T. R.; Strizhak, P. A.; Shevyrev, S. A.; Bogomolov, A. R.

    2017-01-01

    Ignition of an organic water-coal fuel (CWSP) droplet floating in a heated-air flow has been studied experimentally. Rank B2 brown-coal particles with a size of 100 μm, used crankcase Total oil, water, and a plasticizer were used as the main CWSP components. A dedicated quartz-glass chamber has been designed with inlet and outlet elements made as truncated cones connected via a cylindrical ring. The cones were used to shape an oxidizer flow with a temperature of 500-830 K and a flow velocity of 0.5-5.0 m/s. A technique that uses a coordinate-positioning gear, a nichrome thread, and a cutter element has been developed for discharging CWSP droplets into the working zone of the chamber. Droplets with an initial size of 0.4 to 2.0 mm were used. Conditions have been determined for a droplet to float in the oxidizer flow long enough for the sustainable droplet burning to be initiated. Typical stages and integral ignition characteristics have been established. The integral parameters (ignition-delay times) of the examined processes have been compared to the results of experiments with CWSP droplets suspended on the junction of a quick-response thermocouple. It has been shown that floating fuel droplets ignite much quicker than the ones that sit still on the thermocouple due to rotation of an CWSP droplet in the oxidizer flow, more uniform heating of the droplet, and lack of heat drainage towards the droplet center. High-speed video recording of the peculiarities of floatation of a burning fuel droplet makes it possible to complement the existing models of water-coal fuel burning. The results can be used for a more substantiated modeling of furnace CWSP burning with the ANSYS, Fluent, and Sigma-Flow software packages.

  19. Numerical simulation of high-speed turbulent water jets in air

    CERN Document Server

    Guha, Anirban; Balachandar, Ram

    2010-01-01

    Numerical simulation of high-speed turbulent water jets in air and its validation with experimental data has not been reported in the literature. It is therefore aimed to simulate the physics of these high-speed water jets and compare the results with the existing experimental works. High-speed water jets diffuse in the surrounding atmosphere by the processes of mass and momentum transfer. Air is entrained into the jet stream and the entire process contributes to jet spreading and subsequent pressure decay. Hence the physical problem is in the category of multiphase flows, for which mass and momentum transfer is to be determined to simulate the problem. Using the Eulerian multiphase and the k-\\epsilon turbulence models, plus a novel numerical model for mass and momentum transfer, the simulation was achieved. The results reasonably predict the flow physics of high-speed water jets in air.

  20. Blown Away: The Shedding and Oscillation of Sessile Drops by Cross Flowing Air

    Science.gov (United States)

    Milne, Andrew James Barnabas

    For drops sessile on a solid surface, cross flowing air can drive drop oscillation or shedding, based on the balance and interaction of aerodynamic drag force (based on drop size/shape and air speed) and adhesion/capillary forces (based on surface tension and drop size/shape). Better understanding of the above has applications to, e.g., fuel cell flooding, airfoil icing, and visibility in rain. To understand the basic physics, experiments studying individual sessile drops in a low speed wind tunnel were performed in this thesis. Analysis of high speed video gave time resolved profiles and airspeed for shedding. Testing 0.5 mul to 100 mul drops of water and hexadecane on poly(methyl methacrylate) PMMA, Teflon, and a superhydrophobic surface (SHS) yielded a master curve describing critical airspeed for shedding for water drops on all surface tested. This curve predicts behavior for new surfaces, and explains experimental results published previously. It also indicates that the higher contact angle leads to easier shedding due to decreased adhesion and increased drag. Developing a novel floating element differential drag sensor gave the first measurements of the microNewton drag force experienced by drops. Forces magnitude is comparable to gravitational shedding from a tilted plate and to simplified models for drop adhesion, with deviations that suggest effects due to the air flow. Fluid properties are seen to have little effect on drag versus airspeed, and decreased adhesion is seen to be more important than increased drag for easing shedding. The relation between drag coefficient and Reynolds number increases slightly with liquid-solid contact angle, and with drop volume. Results suggest that the drop experiences increased drag compared to similarly shaped solid bodies due to drop oscillations aeroelasticly coupling into the otherwise laminar flow. The bulk and surface oscillations of sessile drops in cross flow was also studied, using a full profile analysis

  1. Expanding NevCAN capabilities: monitoring cold air drainage flow along a narrow wash within a Montane to PJ ecotone

    Science.gov (United States)

    Bird, B. M.; Devitt, D.

    2012-12-01

    Cold air drainage flows are a naturally occurring physical process of mountain systems. Plant communities that exist in cold air drainage basins respond to these localized cold air trends, and have been shown to be decoupled from larger global climate weather systems. The assumption that air temperature decreases with altitude is violated within these systems and climate model results based on this assumption would ultimately be inaccurate. In arid regions, high radiation loads lead to significant long wave radiation being emitted from the ground later in the day. As incoming radiation ceases, the surface very quickly loses energy through radiative processes, leading to surface inversions and enhanced cold air drainage opportunities. This study is being conducted in the Mojave desert on Sheep Mountain located between sites 3 and 4 of the NSF EPSCoR network. Monitoring of cold air drainage was initiated in September of 2011within a narrow ravine located between the 2164 and 2350 meter elevation. We have installed 25 towers (5 towers per location situated at the central low point in a ravine and at equal distances up the sides of the ravine on both the N and S facing slopes) to assess air temperatures from 0.1 meters to a height of 3 meters at 25m intervals. Our goal is to better understand the connection between cold air movement and plant physiological response. The species monitored in this study include: Pinus ponderosa (common name: Ponderosa Pine), Pinus pinyon (Pinyon Pine), Juniperus osteosperma (Utah juniper), Cercocarpus intricatus (Mountain Mahogany) and Symphoricarpos (snowberry). Hourly air temperature measurements within the wash are being captured from 100 ibuttons placed within PVC solar radiation shields. We are also developing a modeling approach to assess the three dimensional movement of cold air over time by incorporating wind vectors captured from 5 2D sonic anemometers. Wind velocities will be paired with air temperatures to better understand

  2. High-energy metal air batteries

    Science.gov (United States)

    Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

    2013-07-09

    Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

  3. Vortex flow formation during dielectric barrier discharge initiation in quiescent air

    NARCIS (Netherlands)

    Golub, V. V.; Saveliev, A. S.

    2010-01-01

    The structure of vortex flows generated by dielectric barrier discharge initiated in quiescent air at atmospheric pressure has been studied by the methods of particle image velocimetry and schlieren photography. The flow parameters have been measured as functions of the time past the electric discha

  4. Flammability limits in flowing ethene-air-nitrogen mixtures: an experimental study

    NARCIS (Netherlands)

    Bolk, J.W.; Siccama, N.B.; Westerterp, K.R.

    1996-01-01

    A large pilot plant was constructed to study the upper flammability limit of ethene-air-nitrogen mixtures under conditions of flow. The gas mixtures flowed through an explosion tube with a length of 3.0 m and a diameter of 21 mm. An electrically heated wire was used as ignition source. Experiments w

  5. A criterion for the onset of slugging in horizontal stratified air-water countercurrent flow

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Moon-Hyun; Lee, Byung-Ryung; Kim, Yang-Seok [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)] [and others

    1995-09-01

    This paper presents an experimental and theoretical investigation of wave height and transition criterion from wavy to slug flow in horizontal air-water countercurrent stratified flow conditions. A theoretical formula for the wave height in a stratified wavy flow regime has been developed using the concept of total energy balance over a wave crest to consider the shear stress acting on the interface of two fluids. From the limiting condition of the formula for the wave height, a necessary criterion for transition from a stratified wavy flow to a slug flow has been derived. A series of experiments have been conducted changing the non-dimensional water depth and the flow rates of air in a horizontal pipe and a duct. Comparisons between the measured data and the predictions of the present theory show that the agreement is within {plus_minus}8%.

  6. Air Ejector Pumping Enhancement Through Pulsing Primary Flow

    Science.gov (United States)

    2005-12-01

    CFD ) analysis show that pulsing the primary jet flow, an active metho of flow control, improved ejector performance. The physics of this improvement...without an entrance shape was found to be still reasonably efficient. Both experiments and Computer Fluid Dynamics( CFD ) analysis show that pulsing the...other shapes. A tube without an entrance shape was found to be still reasonably efficient. Both experiments and Computer Fluid Dynamics( CFD ) analysis

  7. The effects of channel diameter on flow pattern, void fraction and pressure drop of two-phase air-water flow in circular micro-channels

    Energy Technology Data Exchange (ETDEWEB)

    Saisorn, Sira [Energy Division, The Joint Graduate School of Energy and Environment (JGSEE), King Mongkut' s University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand); Wongwises, Somchai [Fluid Mechanics, Thermal Engineering and Multiphase Flow Research Lab. (FUTURE), Department of Mechanical Engineering, King Mongkut' s University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand)

    2010-05-15

    Two-phase air-water flow characteristics are experimentally investigated in horizontal circular micro-channels. Test sections are made of fused silica. The experiments are conducted based on three different inner diameters of 0.53, 0.22 and 0.15 mm with the corresponding lengths of 320, 120 and 104 mm, respectively. The test runs are done at superficial velocities of gas and liquid ranging between 0.37-42.36 and 0.005-3.04 m/s, respectively. The flow visualisation is facilitated by systems mainly including stereozoom microscope and high-speed camera. The flow regime maps developed from the observed flow patterns are presented. The void fractions are determined based on image analysis. New correlation for two-phase frictional multiplier is also proposed for practical applications. (author)

  8. A Computer Program to Calculate the Supersonic Flow over a Solid Cone in Air or Water.

    Science.gov (United States)

    1984-06-01

    ix air or water. The rain objective is to calculate the ccne semi-vertei angle given prescribed initial ccndi- tions. The program is written in...tc the motion of the metal jet frcm an explczive shaped-charge fired underwater. A tiical result for supersonic flow over a ccne in water is as follcws...the ccne semi-vertex angle is calculated to be 7.23 degrees. Gene rally, pressures invclved in water flow are much larger than for air flow, and the

  9. Thin-Film Air-Mass-Flow Sensor of Improved Design Developed

    Science.gov (United States)

    Fralick, Gustave C.; Wrbanek, John D.; Hwang, Danny P.

    2003-01-01

    Researchers at the NASA Glenn Research Center have developed a new air-mass-flow sensor to solve the problems of existing mass flow sensor designs. NASA's design consists of thin-film resistors in a Wheatstone bridge arrangement. The resistors are fabricated on a thin, constant-thickness airfoil to minimize disturbance to the airflow being measured. The following photograph shows one of NASA s prototype sensors. In comparison to other air-mass-flow sensor designs, NASA s thin-film sensor is much more robust than hot wires, causes less airflow disturbance than pitot tubes, is more accurate than vane anemometers, and is much simpler to operate than thermocouple rakes. NASA s thin-film air-mass-flow sensor works by converting the temperature difference seen at each leg of the thin-film Wheatstone bridge into a mass-flow rate. The following figure shows a schematic of this sensor with air flowing around it. The sensor operates as follows: current is applied to the bridge, which increases its temperature. If there is no flow, all the arms are heated equally, the bridge remains in balance, and there is no signal. If there is flow, the air passing over the upstream legs of the bridge reduces the temperature of the upstream legs and that leads to reduced electrical resistance for those legs. After the air has picked up heat from the upstream legs, it continues and passes over the downstream legs of the bridge. The heated air raises the temperature of these legs, increasing their electrical resistance. The resistance difference between the upstream and downstream legs unbalances the bridge, causing a voltage difference that can be amplified and calibrated to the airflow rate. Separate sensors mounted on the airfoil measure the temperature of the airflow, which is used to complete the calculation for the mass of air passing by the sensor. A current application for air-mass-flow sensors is as part of the intake system for an internal combustion engine. A mass-flow sensor is

  10. Effect of volumetric electromagnetic forces on shock wave structure of hypersonic air flow near plate

    Science.gov (United States)

    Fomichev, Vladislav; Yadrenkin, Mikhail; Shipko, Evgeny

    2016-10-01

    Summarizing of experimental studies results of the local MHD-interaction at hypersonic air flow near the plate is presented. Pulsed and radiofrequency discharge have been used for the flow ionization. It is shown that MHD-effect on the shock-wave structure of the flow is significant at test conditions. Using of MHD-interaction parameter enabled to defining characteristic modes of MHD-interaction by the force effect: weak, moderate and strong.

  11. Bifurcations of a creeping air-water flow in a conical container

    Science.gov (United States)

    Balci, Adnan; Brøns, Morten; Herrada, Miguel A.; Shtern, Vladimir N.

    2016-10-01

    This numerical study describes the eddy emergence and transformations in a slow steady axisymmetric air-water flow, driven by a rotating top disk in a vertical conical container. As water height Hw and cone half-angle β vary, numerous flow metamorphoses occur. They are investigated for β =30°, 45°, and 60°. For small Hw, the air flow is multi-cellular with clockwise meridional circulation near the disk. The air flow becomes one cellular as Hw exceeds a threshold depending on β . For all β , the water flow has an unbounded number of eddies whose size and strength diminish as the cone apex is approached. As the water level becomes close to the disk, the outmost water eddy with clockwise meridional circulation expands, reaches the interface, and induces a thin layer with anticlockwise circulation in the air. Then this layer expands and occupies the entire air domain. The physical reasons for the flow transformations are provided. The results are of fundamental interest and can be relevant for aerial bioreactors.

  12. Flow-field differences and electromagnetic-field properties of air and N2 inductively coupled plasmas

    Science.gov (United States)

    Yu, Minghao; Yamada, Kazuhiko; Takahashi, Yusuke; Liu, Kai; Zhao, Tong

    2016-12-01

    A numerical model for simulating air and nitrogen inductively coupled plasmas (ICPs) was developed considering thermochemical nonequilibrium and the third-order electron transport properties. A modified far-field electromagnetic model was introduced and tightly coupled with the flow field equations to describe the Joule heating and inductive discharge phenomena. In total, 11 species and 49 chemical reactions of air, which include 5 species and 8 chemical reactions of nitrogen, were employed to model the chemical reaction process. The internal energy transfers among translational, vibrational, rotational, and electronic energy modes of chemical species were taken into account to study thermal nonequilibrium effects. The low-Reynolds number Abe-Kondoh-Nagano k-ɛ turbulence model was employed to consider the turbulent heat transfer. In this study, the fundamental characteristics of an ICP flow, such as the weak ionization, high temperature but low velocity in the torch, and wide area of the plasma plume, were reproduced by the developed numerical model. The flow field differences between the air and nitrogen ICP flows inside the 10-kW ICP wind tunnel were made clear. The interactions between the electromagnetic and flow fields were also revealed for an inductive discharge.

  13. Detailed analysis of turbulent flows in air curtains

    NARCIS (Netherlands)

    Jaramillo, Julian E.; Perez-Segarra, Carlos D.; Lehmkuhl, Oriol; Castro, Jesus

    2011-01-01

    In order to prevent entrainment, an air curtain should provide a jet with low turbulence level, and enough momentum to counteract pressure differences across the opening. Consequently, the analysis of the discharge plenum should be taken into consideration. Hence, the main object of this paper is to

  14. Propagation of density disturbances in air-water flow

    Science.gov (United States)

    Nassos, G. P.

    1969-01-01

    Study investigated the behavior of density waves propagating vertically in an atmospheric pressure air-water system using a technique based on the correlation between density change and electric resistivity. This information is of interest to industries working with heat transfer systems and fluid power and control systems.

  15. Detailed analysis of turbulent flows in air curtains

    NARCIS (Netherlands)

    Jaramillo, Julian E.; Perez-Segarra, Carlos D.; Lehmkuhl, Oriol; Castro, Jesus

    2011-01-01

    In order to prevent entrainment, an air curtain should provide a jet with low turbulence level, and enough momentum to counteract pressure differences across the opening. Consequently, the analysis of the discharge plenum should be taken into consideration. Hence, the main object of this paper is to

  16. Temperature distribution of air source heat pump barn with different air flow

    Science.gov (United States)

    He, X.; Li, J. C.; Zhao, G. Q.

    2016-08-01

    There are two type of airflow form in tobacco barn, one is air rising, the other is air falling. They are different in the structure layout and working principle, which affect the tobacco barn in the distribution of temperature field and velocity distribution. In order to compare the temperature and air distribution of the two, thereby obtain a tobacco barn whose temperature field and velocity distribution are more uniform. Taking the air source heat pump tobacco barn as the investigated subject and establishing relevant mathematical model, the thermodynamics of the two type of curing barn was analysed and compared based on Fluent. Provide a reasonable evidence for chamber arrangement and selection of outlet for air source heat pump tobacco barn.

  17. Experimental and Numerical Analysis of Air Flow, Heat Transfer and Thermal Comfort in Buildings with Different Heating Systems

    Science.gov (United States)

    Sabanskis, A.; Virbulis, J.

    2016-04-01

    Monitoring of temperature, humidity and air flow velocity is performed in 5 experimental buildings with the inner size of 3×3×3 m3 located in Riga, Latvia. The buildings are equipped with different heating systems, such as an air-air heat pump, air-water heat pump, capillary heating mat on the ceiling and electric heater. Numerical simulation of air flow and heat transfer by convection, conduction and radiation is carried out using OpenFOAM software and compared with experimental data. Results are analysed regarding the temperature and air flow distribution as well as thermal comfort.

  18. The Role of Design-of-Experiments in Managing Flow in Compact Air Vehicle Inlets

    Science.gov (United States)

    Anderson, Bernhard H.; Miller, Daniel N.; Gridley, Marvin C.; Agrell, Johan

    2003-01-01

    It is the purpose of this study to demonstrate the viability and economy of Design-of-Experiments methodologies to arrive at microscale secondary flow control array designs that maintain optimal inlet performance over a wide range of the mission variables and to explore how these statistical methods provide a better understanding of the management of flow in compact air vehicle inlets. These statistical design concepts were used to investigate the robustness properties of low unit strength micro-effector arrays. Low unit strength micro-effectors are micro-vanes set at very low angles-of-incidence with very long chord lengths. They were designed to influence the near wall inlet flow over an extended streamwise distance, and their advantage lies in low total pressure loss and high effectiveness in managing engine face distortion. The term robustness is used in this paper in the same sense as it is used in the industrial problem solving community. It refers to minimizing the effects of the hard-to-control factors that influence the development of a product or process. In Robustness Engineering, the effects of the hard-to-control factors are often called noise , and the hard-to-control factors themselves are referred to as the environmental variables or sometimes as the Taguchi noise variables. Hence Robust Optimization refers to minimizing the effects of the environmental or noise variables on the development (design) of a product or process. In the management of flow in compact inlets, the environmental or noise variables can be identified with the mission variables. Therefore this paper formulates a statistical design methodology that minimizes the impact of variations in the mission variables on inlet performance and demonstrates that these statistical design concepts can lead to simpler inlet flow management systems.

  19. EXPERIMENTAL DEVICE OF THE HIGH HUMIDITY AIR ELECTROSTATIC ELIMINATOR

    Institute of Scientific and Technical Information of China (English)

    吴筱青; 何尉岚

    1990-01-01

    As for electrostatic elimination there are many means.But the high humidity air electrostatic eliminator has simple,efficient, lightproof and fireproof etc. advantages. Thus it is often used in some industrial enterprises. The aim of this paper is to introduce an experimental device of high humidity air electrostatic eliminator and its principle and experimental data.

  20. Quantification of methane in humid air and exhaled breath using selected ion flow tube mass spectrometry.

    Science.gov (United States)

    Dryahina, Kseniya; Smith, D; Spanel, P

    2010-05-15

    In selected ion flow tube mass spectrometry, SIFT-MS, analyses of humid air and breath, it is essential to consider and account for the influence of water vapour in the media, which can be profound for the analysis of some compounds, including H(2)CO, H(2)S and notably CO(2). To date, the analysis of methane has not been considered, since it is known to be unreactive with H(3)O(+) and NO(+), the most important precursor ions for SIFT-MS analyses, and it reacts only slowly with the other available precursor ion, O(2) (+). However, we have now experimentally investigated methane analysis and report that it can be quantified in both air and exhaled breath by exploiting the slow O(2) (+)/CH(4) reaction that produces CH(3)O(2) (+) ions. We show that the ion chemistry is significantly influenced by the presence of water vapour in the sample, which must be quantified if accurate analyses are to be performed. Thus, we have carried out a study of the loss rate of the CH(3)O(2) (+) analytical ion as a function of sample humidity and deduced an appropriate kinetics library entry that provides an accurate analysis of methane in air and breath by SIFT-MS. However, the associated limit of detection is rather high, at 0.2 parts-per-million, ppm. We then measured the methane levels, together with acetone levels, in the exhaled breath of 75 volunteers, all within a period of 3 h, which shows the remarkable sample throughput rate possible with SIFT-MS. The mean methane level in ambient air is seen to be 2 ppm with little spread and that in exhaled breath is 6 ppm, ranging from near-ambient levels to 30 ppm, with no significant variation with age and gender. Methane can now be included in the wide ranging analyses of exhaled breath that are currently being carried out using SIFT-MS.

  1. Homogenization of High-Contrast Brinkman Flows

    KAUST Repository

    Brown, Donald L.

    2015-04-16

    Modeling porous flow in complex media is a challenging problem. Not only is the problem inherently multiscale but, due to high contrast in permeability values, flow velocities may differ greatly throughout the medium. To avoid complicated interface conditions, the Brinkman model is often used for such flows [O. Iliev, R. Lazarov, and J. Willems, Multiscale Model. Simul., 9 (2011), pp. 1350--1372]. Instead of permeability variations and contrast being contained in the geometric media structure, this information is contained in a highly varying and high-contrast coefficient. In this work, we present two main contributions. First, we develop a novel homogenization procedure for the high-contrast Brinkman equations by constructing correctors and carefully estimating the residuals. Understanding the relationship between scales and contrast values is critical to obtaining useful estimates. Therefore, standard convergence-based homogenization techniques [G. A. Chechkin, A. L. Piatniski, and A. S. Shamev, Homogenization: Methods and Applications, Transl. Math. Monogr. 234, American Mathematical Society, Providence, RI, 2007, G. Allaire, SIAM J. Math. Anal., 23 (1992), pp. 1482--1518], although a powerful tool, are not applicable here. Our second point is that the Brinkman equations, in certain scaling regimes, are invariant under homogenization. Unlike in the case of Stokes-to-Darcy homogenization [D. Brown, P. Popov, and Y. Efendiev, GEM Int. J. Geomath., 2 (2011), pp. 281--305, E. Marusic-Paloka and A. Mikelic, Boll. Un. Mat. Ital. A (7), 10 (1996), pp. 661--671], the results presented here under certain velocity regimes yield a Brinkman-to-Brinkman upscaling that allows using a single software platform to compute on both microscales and macroscales. In this paper, we discuss the homogenized Brinkman equations. We derive auxiliary cell problems to build correctors and calculate effective coefficients for certain velocity regimes. Due to the boundary effects, we construct

  2. Slug flow transitions in horizontal gas/liquid two-phase flows. Dependence on channel height and system pressure for air/water and steam/water two-phase flows

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Hideo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-05-01

    The slug flow transitions and related phenomena for horizontal two-phase flows were studied for a better prediction of two-phase flows that typically appear during the reactor loss-of-coolant accidents (LOCAs). For better representation of the flow conditions experimentally, two large-scaled facility: TPTF for high-pressure steam/water two-phase flows and large duct test facility for air/water two-phase flows, were used. The visual observation of the flow using a video-probe was performed in the TPTF experiments for good understanding of the phenomena. The currently-used models and correlations based mostly on the small-scale low-pressure experiments were reviewed and improved based on these experimental results. The modified Taitel-Dukler model for prediction of transition into slug flow from wavy flow and the modified Steen-Wallis correlation for prediction of onset of liquid entrainment from the interfacial waves were obtained. An empirical correlation for the gas-liquid interfacial friction factor was obtained further for prediction of liquid levels at wavy flow. The region of slug flow regime that is generally under influences of the channel height and system pressure was predicted well when these models and correlations were applied together. (author). 90 refs.

  3. Prediction of Air Flow and Temperature Distribution Inside a Yogurt Cooling Room Using Computational Fluid Dynamics

    Directory of Open Access Journals (Sweden)

    A Surendhar

    2015-01-01

    Full Text Available Air flow and heat transfer inside a yogurt cooling room were analysed using Computational Fluid Dynamics. Air flow and heat transfer models were based on 3D, unsteady state, incompressible, Reynolds-averaged Navier-Stokes equations and energy equations. Yogurt cooling room was modelled with the measured geometry using 3D design tool AutoCAD. Yogurt cooling room model was exported into the flow simulation software by specifying properties of inlet air, yogurt, pallet and walls of the room. Packing material was not considered in this study because of less thickness (cup-0.5mm, carton box-1.5mm and negligible resistance created in the conduction of heat. 3D Computational domain was meshed with hexahedral cells and governing equations were solved using explicit finite volume method. Air flow pattern inside the room and the temperature distribution in the bulk of palletized yogurt were predicted. Through validation, the variation in the temperature distribution and velocity vector from the measured value was found to be 2.0oC (maximum and 30% respectively. From the simulation and the measured value of the temperature distribution, it was observed that the temperature was non-uniform over the bulk of yogurt. This might be due to refrigeration capacity, air flow pattern, stacking of yogurt or geometry of the room. Required results were achieved by changing the location of the cooling fan.

  4. Air flow over foredunes and implications for sand transport

    NARCIS (Netherlands)

    S.M. Arens; H.M.E. van Kaam-Peters; J.H. van Boxel

    1995-01-01

    More than 4000 hourly wind profiles measured on three topographically different foredunes are analysed and discussed. Wind flow over the foredunes is studied by means of the relative wind speed: the ratio between wind speed at a certain location and the reference wind speed at the same height. Relat

  5. Experimental and numerical investigations on reliability of air barrier on oil containment in flowing water.

    Science.gov (United States)

    Lu, Jinshu; Xu, Zhenfeng; Xu, Song; Xie, Sensen; Wu, Haoxiao; Yang, Zhenbo; Liu, Xueqiang

    2015-06-15

    Air barriers have been recently developed and employed as a new type of oil containment boom. This paper presents systematic investigations on the reliability of air barriers on oil containments with the involvement of flowing water, which represents the commonly-seen shearing current in reality, by using both laboratory experiments and numerical simulations. Both the numerical and experimental investigations are carried out in a model scale. In the investigations, a submerged pipe with apertures is installed near the bottom of a tank to generate the air bubbles forming the air curtain; and, the shearing water flow is introduced by a narrow inlet near the mean free surface. The effects of the aperture configurations (including the size and the spacing of the aperture) and the location of the pipe on the effectiveness of the air barrier on preventing oil spreading are discussed in details with consideration of different air discharges and velocities of the flowing water. The research outcome provides a foundation for evaluating and/or improve the reliability of a air barrier on preventing spilled oil from further spreading.

  6. Migration of Air Flow in Non-Fixed Saturated Porous Medium

    Science.gov (United States)

    Kong, X.; Fritz, S.; Kinzelbach, W.

    2008-12-01

    Two phase flow in porous media is of importance in a number of processes relevant in environmental engineering. The study of gas movement following injection into liquid saturated porous media is an active area of exploration for theoretical and practical reasons, e.g., in air-sparging, oil recovery, and bio-filter. A set of two-dimensional laboratory visualization experiments reveals a previously unrecognized gas-flow instability in a liquid-saturated porous medium packed by its own weight. The medium is made of crushed fused silica glass and saturated with a glycerine-water solution for refractive-index-matching. The interaction of the air flow injected at the bottom and the matrix (porous medium) structure leads to mobilization of the matrix and an instability, which causes the air channel to migrate. The instability of air-channel migration differs significantly from the gas-flow instability in a fixed matrix described in previous research. The migration of the air channel appears as a sequence of former channels collapsing and new channels opening. This process is characterized by the reorganization of the matrix, and the switching between channelized flow and pulsating slug flow. The channel migration comes to a stop after some time, leaving one thin and stable channel. The process is studied by calculating the cumulated lateral movement distance of channel and the lateral width of the area affected by the migration. A dimensionless number is defined to describe the migration. It is observed to be a function of grain size, height of bed, and air flow rate.

  7. Simulation of the air flows in many industrial pleated filters; Modelisation des ecoulements d'air dans differents filtres industriels plisses

    Energy Technology Data Exchange (ETDEWEB)

    Del Fabbro, L.; Brun, P. [FILTRAUTO, 78 - Saint-Quentin-en-Yvelines (France); Laborde, J.C.; Lacan, J.; Ricciardi, L. [CEA/Saclay, Inst. de Protection et de Surete Nucleaire, IPSN/DPEA/SERAC, 91 - Gif-sur-Yvette (France); Renoux, A. [Paris-12 Univ., Lab. de Physique des Aerosols et de Transfert des Contaminations, 94 - Creteil (France)

    2000-07-01

    The study presents results concerning the characterization of the charge loss and the air flow in nuclear and automobile type pleated filters. The experimental studies in correlation with the numerical models showed an homogenous distribution of the air flows in a THE nuclear type filter, whereas the distribution is heterogenous in the case of an automobile filter. (A.L.B.)

  8. High surface area carbon for bifunctional air electrodes applied in zinc-air batteries

    Energy Technology Data Exchange (ETDEWEB)

    Arai, H. [on leave from NTT Laboratories (Japan); Mueller, S.; Haas, O. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Bifunctional air electrodes with high surface area carbon substrates showed low reduction overpotential, thus are promising for enhancing the energy efficiency and power capability of zinc-air batteries. The improved performance is attributed to lower overpotential due to diffusion of the reaction intermediate, namely the peroxide ion. (author) 1 fig., 2 refs.

  9. Verification and Validation of Numerical Models for Air/Water Flow on Coastal and Navigation Fluid-Structure Interaction Applications

    Science.gov (United States)

    Kees, C. E.; Farthing, M.; Dimakopoulos, A.; DeLataillade, T.

    2015-12-01

    Performance analysis and optimization of coastal and navigation structures is becoming feasible due to recent improvements in numerical methods for multiphase flows and the steady increase in capacity and availability of high performance computing resources. Now that the concept of fully three-dimensional air/water flow modelling for real world engineering analysis is achieving acceptance by the wider engineering community, it is critical to expand careful comparative studies on verification,validation, benchmarking, and uncertainty quantification for the variety of competing numerical methods that are continuing to evolve. Furthermore, uncertainty still remains about the relevance of secondary processes such as surface tension, air compressibility, air entrainment, and solid phase (structure) modelling so that questions about continuum mechanical theory and mathematical analysis of multiphase flow are still required. Two of the most popular and practical numerical approaches for large-scale engineering analysis are the Volume-Of-Fluid (VOF) and Level Set (LS) approaches. In this work we will present a publically available verification and validation test set for air-water-structure interaction problems as well as computational and physical model results including a hybrid VOF-LS method, traditional VOF methods, and Smoothed Particle Hydrodynamics (SPH) results. The test set repository and test problem formats will also be presented in order to facilitate future comparative studies and reproduction of scientific results.

  10. Flow and performance of an air-curtain biological safety cabinet.

    Science.gov (United States)

    Huang, Rong Fung; Chou, Chun I

    2009-06-01

    Using laser-assisted smoke flow visualization and tracer gas concentration detection techniques, this study examines aerodynamic flow properties and the characteristics of escape from containment, inward dispersion, and cross-cabinet contamination of a biological safety cabinet installed with an air curtain across the front aperture. The experimental method partially simulates the NSF/ANSI 49 standards with the difference that the biological tracer recommended by these standards is replaced by a mixture of 10% SF(6) in N(2). The air curtain is set up across the cabinet aperture plane by means of a narrow planar jet issued from the lower edge of the sash and a suction flow going through a suction slot installed at the front edge of the work surface. Varying the combination of jet velocity, suction flow velocity, and descending flow velocity reveals three types of characteristic flow modes: 'straight curtain', 'slightly concave curtain', and 'severely concave curtain'. Operating the cabinet in the straight curtain mode causes the air curtain to impinge on the doorsill and therefore induces serious escape from containment. In the severely concave curtain mode, drastically large inward dispersion and cross-cabinet contamination were observed because environmental air entered into the cabinet and a three-dimensional vortical flow structure formed in the cabinet. The slightly concave curtain mode presents a smooth and two-dimensional flow pattern with an air curtain separating the outside atmosphere from the inside space of the cabinet, and therefore exhibited negligibly small escape from containment, inward dispersion, and cross-cabinet contamination.

  11. Effect of Moist Air on Transonic Internal Flow around a Plate

    Science.gov (United States)

    Hasan, A. B. M. Toufique; Matsuo, Shigeru; Setoguchi, Toshiaki; Kim, Heuy Dong

    The unsteady phenomena in the transonic flow around airfoils are observed in the flow field of fan, compressor blades and butterfly valves, and this causes often serious problems such as the aeroacoustic noise and the vibration. In the transonic or supersonic flow where vapor is contained in the main flow, the rapid expansion of the flow may give rise to a non-equilibrium condensation. In the present study, the effect of non-equilibrium condensation of moist air on the shock induced flow field oscillation around a plate was investigated numerically. The results showed that in the case with non-equilibrium condensation, the flow field aerodynamic unsteadiness is reduced significantly compared with those without the non-equilibrium condensation.

  12. Effect of Nonequilibrium Condensation of Moist Air on Transonic Flow Fields

    Institute of Scientific and Technical Information of China (English)

    KatsumiShimamoto

    2000-01-01

    When condensation occurs in a supersonic flow field,the flow in affected by the latent heat released.In the present study,a condensing flow was produced by an expansion of moist air in nozzle with circular bump odels and shock waves occurred in the supersonic parts of the flow fields.The expereimental investigations were carried out to show the effects of initial conditions in the reservoir and nozzle geometries on the shock wave characteristics and the turbulences in the flow fields.Furthermore,in order to clarify the effect of condensation on the flow fields with shock waves,navier-Stokes equations were solved numerically using a 3rd-order MUSCL type TVD finite-difference scheme with a second order fractional step for time integraton,As a result,the effect of condensation on the aspect of flow field has been clarified.

  13. Flow characteristics of an inclined air-curtain range hood in a draft.

    Science.gov (United States)

    Chen, Jia-Kun

    2015-01-01

    The inclined air-curtain technology was applied to build an inclined air-curtain range hood. A draft generator was applied to affect the inclined air-curtain range hood in three directions: lateral (θ=0°), oblique (θ=45°), and front (θ=90°). The three suction flow rates provided by the inclined air-curtain range hood were 10.1, 10.9, and 12.6 m(3)/min. The laser-assisted flow visualization technique and the tracer-gas test method were used to investigate the performance of the range hood under the influence of a draft. The results show that the inclined air-curtain range hood has a strong ability to resist the negative effect of a front draft until the draft velocity is greater than 0.5 m/s. The oblique draft affected the containment ability of the inclined air-curtain range hood when the draft velocity was larger than 0.3 m/s. When the lateral draft effect was applied, the capture efficiency of the inclined air-curtain range hood decreased quickly in the draft velocity from 0.2 m/s to 0.3 m/s. However, the capture efficiencies of the inclined air-curtain range hood under the influence of the front draft were higher than those under the influence of the oblique draft from 0.3 m/s to 0.5 m/s.

  14. Minor Losses During Air Flow into Granular Porous Media

    DEFF Research Database (Denmark)

    Poulsen, Tjalfe Gorm; Minelgaite, Greta; Bentzen, Thomas Ruby

    2013-01-01

    Pressure gradients during uniform fluid flow in porous media are traditionally assumed to be linear. Thus, pressure loss across a sample of porous medium is assumed directly proportional to the thickness of the sample. In this study, measurements of pressure gradients inside coarse granular (2...... that the pressure loss in porous media consists of two components: (1) a linear pressure gradient and (2) an initial pressure loss near the inlet. This initial pressure loss is also known from hydraulics in tubes as a minor loss and is associated with abrupt changes in the flow field such as narrowings and bends....... The results further indicated that the minor loss depends on the particle size and particle size distribution in a manner similar to that of the linear pressure gradient. There is, thus, a close relation between these two components. In porous media, the minor loss is not instantaneous at the inlet point...

  15. Determination of ethane, pentane and isoprene in exhaled air--effects of breath-holding, flow rate and purified air.

    Science.gov (United States)

    Lärstad, M A E; Torén, K; Bake, B; Olin, A-C

    2007-01-01

    Exhaled ethane, pentane and isoprene have been proposed as biomarkers of oxidative stress. The objectives were to explore whether ethane, pentane and isoprene are produced within the airways and to explore the effect of different sampling parameters on analyte concentrations. The flow dependency of the analyte concentrations, the concentrations in dead-space and alveolar air after breath-holding and the influence of inhaling purified air on analyte concentrations were investigated. The analytical method involved thermal desorption from sorbent tubes and gas chromatography. The studied group comprised 13 subjects with clinically stable asthma and 14 healthy controls. Ethane concentrations decreased slightly, but significantly, at higher flow rates in subjects with asthma (P = 0.0063) but not in healthy controls. Pentane levels were increased at higher flow rates both in healthy and asthmatic subjects (P = 0.022 and 0.0063 respectively). Isoprene levels were increased at higher flow rates, but only significantly in healthy subjects (P = 0.0034). After breath-holding, no significant changes in ethane levels were observed. Pentane and isoprene levels increased significantly after 20 s of breath-holding. Inhalation of purified air before exhalation resulted in a substantial decrease in ethane levels, a moderate decrease in pentane levels and an increase in isoprene levels. The major fractions of exhaled ethane, pentane and isoprene seem to be of systemic origin. There was, however, a tendency for ethane to be flow rate dependent in asthmatic subjects, although to a very limited extent, suggesting that small amounts of ethane may be formed in the airways.

  16. Exposure Due to Interacting Air flows Between Two Persons

    DEFF Research Database (Denmark)

    Bjørn, Erik; Nielsen, Peter V.

    The contaminant concentration inhaled by an occupant (ie. the personal exposure) is usually less than the return concentration in displacement ventilated rooms. Two main questions are investigated: 1) Does the exhalation from one person penetrate the breathing zone of another person placed nearby......, thus leading to larger personal exposure? 2) When two persons are placed close to each other, do the convective boundary layer flows interact so that the personal exposure to an ambient concentration field is altered?...

  17. Overheat Instability in an Ascending Moist Air Flow as a Mechanism of Hurricane Formation

    CERN Document Server

    Nechayev, Andrei

    2011-01-01

    The universal instability mechanism in an ascending moist air flow is theoretically proposed and analyzed. Its origin comes to the conflict between two processes: the increasing of pressure forcing applied to the boundary layer and the decelerating of the updraft flow due to air heating. It is shown that the intensification of tropical storm with the redistribution of wind velocities, pressure and temperature can result from the reorganization of the dissipative structure which key parameters are the moist air lifting velocity and the temperature of surrounding atmosphere. This reorganization can lead to formation of hurricane eye and inner ring of convection. A transition of the dissipative structure in a new state can occur when the temperature lapse rate in a zone of air lifting reaches certain critical value. The accordance of observational data with the proposed theoretical description is shown.

  18. Experimental study on heat transfer performance of aluminium foam parallel-flow condenser in air conditioner

    Science.gov (United States)

    Zhang, X.; Wan, Z. M.; Chang, H. W.; Wang, Y. D.

    2017-01-01

    Open cell aluminium foam was used in parallel-flow condenser in air conditioner, and two condensers with different pore density were fabricated. The experimental study was conducted on the heat transfer performance and temperature distribution. The experimental results show that both of the heat transfer load and air pressure drop increase with the increase of pore density, air velocity is 2.5m/s, the heat transfer capacities of the condenser with 10PPI and 8PPI are 4.786kw and 3.344kW respectively. Along the flow direction of refrigerant, the outlet temperatures of refrigerant drop with the rise of air velocity when the inlet temperature is constant. The outlet temperature of the refrigerant decreases with the increase of pore density.

  19. Measurement and Determination of Friction Characteristic of Air Flow through Porous Media

    Directory of Open Access Journals (Sweden)

    Wei Zhong

    2015-03-01

    Full Text Available Sintered metal porous media currently plays an important role in air bearing systems. When flowing through porous media, the flow properties are generally represented by incompressible Darcy-Forchheimer regime or Ergun regime. In this study, a modified Ergun equation, which includes air compressibility effects, is developed to describe friction characteristic. Experimental and theoretical investigations on friction characteristic are conducted with a series of metal-sintered porous media. Re = 10 is selected as the boundary for a viscous drag region and a form drag region. Experimental data are first used to determine the coefficient α in the viscous drag region, and then the coefficient β in the form drag region, rather than both simultaneously. Also, the theoretical mass flow rate in terms of the modified Ergun equation provides close approximations to the experimental data. Finally, it is also known that both the air compressibility and inertial effects can obviously enhance the pressure drop.

  20. Flow Alteration and Chemical Reduction: Air Stripping to Lessen Subsurface Discharges of Mercury to Surface Water

    Science.gov (United States)

    Brooks, S. C.; Bogle, M.; Liang, L.; Miller, C. L.; Peterson, M.; Southworth, G. R.; Spalding, B. P.

    2009-12-01

    Mercury concentrations in groundwater, surface water, and biota near an industrial facility in Oak Ridge, Tennessee remain high some 50 years after the original major releases from the facility to the environment. Since the mid-1980s, various remedial and abatement actions have been implemented at the facility, including re-routing water flows, armoring contaminated stream banks, relining or cleanout of facility storm drains, and activated charcoal treatment of groundwater and sump discharges. These actions were taken to reduce inorganic mercury inputs from the facility to the stream; a strategy that assumes limiting the inorganic mercury precursor will reduce Hg methylation and its subsequent bioaccumulation. To date, such actions have reduced mercury loading from the site by approximately 90% from levels typical of the mid 1980's, but waterborne mercury at the facility boundary remains roughly 100 times the typical local background concentration and methylmercury accumulation in aquatic biota exceed standards for safe consumption by humans and wildlife. In 2008 and 2009, a series of investigations was initiated to explore innovative approaches to further control mercury concentrations in stream water. Efforts in this study focused on decreasing waterborne inorganic mercury inputs from two sources. The first, a highly localized source, is the discharge point of the enclosed stormdrain network whereas the second is a more diffuse short reach of stream where metallic Hg in streambed sediments generates a continued input of dissolved Hg to the overlying water. Moving a clean water flow management discharge point to a position downstream of the contaminated reach reduced mercury loading from the streambed source by 75% - 100%, likely by minimizing resuspension of Hg-rich fine particulates and changing characteristic hyporheic flow path length and residence time. Mercury in the stormdrain discharge exists as highly reactive dissolved Hg(II) due to residual chlorine in

  1. Computation of compressible flows with high density ratio and pressure ratio

    Institute of Scientific and Technical Information of China (English)

    CHEN Rong-san

    2008-01-01

    The WENO method, RKDG method, RKDG method with original ghost fluid method, and RKDG method with modified ghost fluid method are applied to single-medium and two-medium air-air, air-liquid compressible flows with high density and pressure ratios. We also provide a numerical comparison and analysis for the above methods. Numerical results show that, compared with the other methods, the RKDG method with modified ghost fluid method can obtain high resolution results and the correct position of the shock, and the computed solutions are converged to the physical solutions as the mesh is refined.

  2. 30 CFR 57.22212 - Air flow (I-C, II-A, and V-A mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air flow (I-C, II-A, and V-A mines). 57.22212... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22212 Air flow (I-C, II-A, and V-A mines). Air flow across each working face shall be sufficient to carry away any accumulation of methane,...

  3. Numerical study of water management in the air flow channel of a PEM fuel cell cathode

    Energy Technology Data Exchange (ETDEWEB)

    Quan, Peng; Lai, Ming-Chia [Department of Mechanical Engineering, Wayne State University, Detroit, MI 48202 (United States)

    2007-01-10

    The water management in the air flow channel of a proton exchange membrane (PEM) fuel cell cathode is numerically investigated using the FLUENT software package. By enabling the volume of fraction (VOF) model, the air-water two-phase flow can be simulated under different operating conditions. The effects of channel surface hydrophilicity, channel geometry, and air inlet velocity on water behavior, water content inside the channel, and two-phase pressure drop are discussed in detail. The results of the quasi-steady-state simulations show that: (1) the hydrophilicity of reactant flow channel surface is critical for water management in order to facilitate water transport along channel surfaces or edges; (2) hydrophilic surfaces also increase pressure drop due to liquid water spreading; (3) a sharp corner channel design could benefit water management because it facilitates water accumulation and provides paths for water transport along channel surface opposite to gas diffusion layer; (4) the two-phase pressure drop inside the air flow channel increases almost linearly with increasing air inlet velocity. (author)

  4. Physical modelling and scale effects of air-water flows on stepped spillways

    Institute of Scientific and Technical Information of China (English)

    CHANSON Hubert; GONZALEZ Carlos A.

    2005-01-01

    During the last three decades, the introduction of new construction materials (e.g. RCC (Roller Compacted Concrete),strengthened gabions) has increased the interest for stepped channels and spillways. However stepped chute hydraulics is not simple, because of different flow regimes and importantly because of very-strong interactions between entrained air and turbulence. In this study, new air-water flow measurements were conducted in two large-size stepped chute facilities with two step heights in each facility to study experimental distortion caused by scale effects and the soundness of result extrapolation to prototypes. Experimental data included distributions of air concentration, air-water flow velocity, bubble frequency, bubble chord length and air-water flow turbulence intensity. For a Froude similitude, the results implied that scale effects were observed in both facilities, although the geometric scaling ratio was only Lr=2 in each case. The selection of the criterion for scale effects is a critical issue. For example, major differences (i.e. scale effects) were observed in terms of bubble chord sizes and turbulence levels although little scale effects were seen in terms of void fraction and velocity distributions. Overall the findings emphasize that physical modelling of stepped chutes based upon a Froude similitude is more sensitive to scale effects than classical smooth-invert chute studies, and this is consistent with basic dimensional analysis developed herein.

  5. Method of measuring the quantity of air liberated in aviation fuel flow at low pipeline pressure

    Science.gov (United States)

    Kitanin, É. L.; Kitanina, E. É.; Zherebtsov, V. A.; Merkulov, O. A.; Peganova, M. M.; Bondarenko, D. A.; Morrison, D.

    2013-09-01

    This paper presents the results of experimental studies of the quantity of air liberated in the flow of aviation fuel in the pipe at a low pressure. Experiments were carried out in the pressure range from 0.2 to 1.0 bar, and the temperature was varied from -20 to +20°C. We propose a method for determining the mass concentration of air dissolved in the fuel measured with the help of a chromatograph. An attempt to use an optical method for measuring the gas content of the flow has shown that it is useful in combination with a chromatographic method needed to calibrate the optical scheme.

  6. Engineering Model of High Pressure Moist Air

    OpenAIRE

    Hyhlík Tomáš

    2017-01-01

    The article deals with the moist air equation of state. There are equations of state discussed in the article, i.e. the model of an ideal mixture of ideal gases, the model of an ideal mixture of real gases and the model based on the virial equation of state. The evaluation of sound speed based on the ideal mixture concept is mentioned. The sound speed calculated by the model of an ideal mixture of ideal gases is compared with the sound speed calculated by using the model based on the concept ...

  7. Air flow phenomena in the model of the blind drift

    Directory of Open Access Journals (Sweden)

    Jaszczur Marek

    2016-01-01

    Full Text Available In the presented paper, Particle Image Velocimetry (PIV has been used to investigate flow pattern and turbulent structure in the model of blind drift. The presented model exist in mining, and has been analyzed to resolve ventilation issues. Blind region is particularly susceptible to unsafe methane accumulation. The measurement system allows us to evaluate all components of the velocity vector in channel cross-section simultaneously. First order and second order statistic of the velocity fields from different channel cross-section are computed and analyzed.

  8. A Lithium-Air Battery with a High Energy Air Cathode Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will advance an efficient and lightweight energy storage device for Oxygen Concentrators by developing a high specific energy lithium-air cell....

  9. High Flow Nasal Cannulae in preterm infants

    Directory of Open Access Journals (Sweden)

    F. Ciuffini

    2013-06-01

    Full Text Available Despite of improved survival of premature infants, the incidence of long term pulmonary complications, mostly associated with ventilation-induced lung injury, remains high. Non invasive ventilation (NIV is able to reduce the adverse effects of mechanical ventilation. Although nasal continuous positive airway pressure (NCPAP is an effective mode of NIV, traumatic nasal complications and intolerance of the nasal interface are common. Recently high flow nasal cannula (HFNC is emerging as an efficient, better tolerated form of NIV, allowing better access to the baby’s face, which may improve nursing, feeding and bonding. The aim of this review is to discuss the available evidence of effectiveness and safety of HFNC in preterm newborns with respiratory distress syndrome (RDS. It is known that distending pressure generated by HFNC increases with increasing flow rate and decreasing infant size and varies according to the amount of leaks by nose and mouth. The effects of HFNC on lung mechanics, its clinical efficacy and safety are still insufficiently investigated. In conclusion, there is a growing evidence of the feasibility of HFNC as an alternative mode of NIV. However, further larger randomized trials are required, before being able to recommend HFNC in the treatment of moderate respiratory distress of preterm infants.

  10. Experimental Studies of Active and Passive Flow Control Techniques Applied in a Twin Air-Intake

    Directory of Open Access Journals (Sweden)

    Akshoy Ranjan Paul

    2013-01-01

    Full Text Available The flow control in twin air-intakes is necessary to improve the performance characteristics, since the flow traveling through curved and diffused paths becomes complex, especially after merging. The paper presents a comparison between two well-known techniques of flow control: active and passive. It presents an effective design of a vortex generator jet (VGJ and a vane-type passive vortex generator (VG and uses them in twin air-intake duct in different combinations to establish their effectiveness in improving the performance characteristics. The VGJ is designed to insert flow from side wall at pitch angle of 90 degrees and 45 degrees. Corotating (parallel and counterrotating (V-shape are the configuration of vane type VG. It is observed that VGJ has the potential to change the flow pattern drastically as compared to vane-type VG. While the VGJ is directed perpendicular to the side walls of the air-intake at a pitch angle of 90 degree, static pressure recovery is increased by 7.8% and total pressure loss is reduced by 40.7%, which is the best among all other cases tested for VGJ. For bigger-sized VG attached to the side walls of the air-intake, static pressure recovery is increased by 5.3%, but total pressure loss is reduced by only 4.5% as compared to all other cases of VG.

  11. Experimental studies of active and passive flow control techniques applied in a twin air-intake.

    Science.gov (United States)

    Paul, Akshoy Ranjan; Joshi, Shrey; Jindal, Aman; Maurya, Shivam P; Jain, Anuj

    2013-01-01

    The flow control in twin air-intakes is necessary to improve the performance characteristics, since the flow traveling through curved and diffused paths becomes complex, especially after merging. The paper presents a comparison between two well-known techniques of flow control: active and passive. It presents an effective design of a vortex generator jet (VGJ) and a vane-type passive vortex generator (VG) and uses them in twin air-intake duct in different combinations to establish their effectiveness in improving the performance characteristics. The VGJ is designed to insert flow from side wall at pitch angle of 90 degrees and 45 degrees. Corotating (parallel) and counterrotating (V-shape) are the configuration of vane type VG. It is observed that VGJ has the potential to change the flow pattern drastically as compared to vane-type VG. While the VGJ is directed perpendicular to the side walls of the air-intake at a pitch angle of 90 degree, static pressure recovery is increased by 7.8% and total pressure loss is reduced by 40.7%, which is the best among all other cases tested for VGJ. For bigger-sized VG attached to the side walls of the air-intake, static pressure recovery is increased by 5.3%, but total pressure loss is reduced by only 4.5% as compared to all other cases of VG.

  12. Effect of Marangoni Flows on the Shape of Thin Sessile Droplets Evaporating into Air

    Science.gov (United States)

    Tsoumpas, Yannis; Dehaeck, Sam; Rednikov, Alexey; Colinet, Pierre

    2015-11-01

    With the help of Mach-Zehnder interferometry, we study the (largely) axisymmetric shapes of freely receding evaporating sessile droplets of various HFE liquids. The droplets evaporate into ambient air and, although the liquids are perfectly wetting, possess small finite contact angles reckoned to be evaporation-induced. The experimentally determined droplet profiles are shown here to deviate, under some conditions, from the classical macroscopic static profile of a sessile droplet, as this is determined by gravity and capillarity. These deviations are attributed to a Marangoni flow, due to evaporation-induced thermal gradients along the liquid-air interface, and are mostly observed in conditions of high evaporation. Unlike the classical static shapes, the distorted experimental profiles exhibit an inflection point at the contact line area. When a poorly volatile liquid is considered, however, the temperature differences and the Marangoni stresses are weak, and the measurements are found to be in a good agreement with the classical static shape. Overall, the experimental findings are quantitatively confirmed by the predictions of a lubrication model accounting for the impact of the Marangoni effect on the droplet shape. Financial support of FP7 Marie Curie MULTIFLOW Network (PITNGA-2008-214919), ESA/BELSPO-PRODEX, BELSPO- μMAST (IAP 7/38) & FRS-FNRS is gratefully acknowledged.

  13. Viscous Potential Flow Analysis of Electroaerodynamic Instability of a Liquid Sheet Sprayed with an Air Stream

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Awasthi

    2013-01-01

    Full Text Available The instability of a thin sheet of viscous and dielectric liquid moving in the same direction as an air stream in the presence of a uniform horizontal electric field has been carried out using viscous potential flow theory. It is observed that aerodynamic-enhanced instability occurs if the Weber number is much less than a critical value related to the ratio of the air and liquid stream velocities, viscosity ratio of two fluids, the electric field, and the dielectric constant values. Liquid viscosity has stabilizing effect in the stability analysis, while air viscosity has destabilizing effect.

  14. Parameters of the plasma of a dc pulsating discharge in a supersonic air flow

    Energy Technology Data Exchange (ETDEWEB)

    Shibkov, V. M., E-mail: shibkov@phys.msu.ru; Shibkova, L. V.; Logunov, A. A. [Moscow State University, Faculty of Physics (Russian Federation)

    2017-03-15

    A dc discharge in a cold (T = 200 K) supersonic air flow at a static pressure of 200–400 Torr was studied experimentally. The excited unsteady pulsating discharge has the form of a thin plasma channel with a diameter of ≤1 mm, stretched downstream the flow. Depending on the discharge current, the pulsation frequency varies from 800 to 1600 Hz and the electron temperature varies from 8000 to 15000 K.

  15. Optical diagnostics study of air flow and powder fluidisation in Nexthaler®--Part I: Studies with lactose placebo formulation.

    Science.gov (United States)

    Pasquali, I; Merusi, C; Brambilla, G; Long, E J; Hargrave, G K; Versteeg, H K

    2015-12-30

    Effective drug delivery to the lungs by a DPI device requires the air-stream through the device to have sufficient power to aerosolise the powder. Furthermore, sufficient turbulence must be induced, along with particle-wall and particle-particle collisions, in order to de-aggregate small drug particles from large carrier particles. As a result, the emitted and the fine particle doses produced by many commercially available DPI devices tend to be strongly affected by the natural inter-patient variability of the inhaled air flow. The Nexthaler® is a multi-dose breath-actuated dry-powder inhaler with minimum drug delivery-flow rate dependency and incorporating a dose protector. The actuation mechanism of the dose-protector ensures that the dose is only exposed to the inhaled air flow if the flow has sufficient power to cause complete aerosolisation. For this study, a proprietary lactose placebo powder blend was filled into "transparent" Nexthaler® to allow application of high-speed imaging and particle image velocimetry (PIV) techniques to successfully interrogate and reveal details of the powder entrainment and emission processes coupled with characterisation of the flow environment in the vicinity of the mouthpiece exit. The study showed that fluidisation of the bulk of the powder occurs very quickly (∼20ms) after withdrawal of the dose protector followed by powder emission from the device within ∼50ms thereafter. The bulk of the metered placebo dose was emitted within 100-200ms. The visualisation study also revealed that a very small fraction of powder fines is emitted whilst the dose protector still covers the dosing cup as the flow rate through the device accelerates. The PIV results show that the flow exiting the device is highly turbulent with a rotating flow structure, which forces the particles to follow internal paths having a high probability of wall impacts, suggesting that the flow environment inside the Nexthaler® DPI will be very beneficial for

  16. Experimental study of the effects of a transversal air-flow deflector in electronics air-cooling

    Science.gov (United States)

    Rebay, M.; Arfaoui, A.; Padet, J.; Ben Maad, R.

    2011-03-01

    This paper presents an experimental investigation of the influence of a transversal flow deflector on the cooling of a heated block mounted on a flat plate. The deflector is inclined and therefore it guides the air flow to the upper surface of the block. This configuration is simulating the air-cooling of a rectangular integrated circuit or a current converter mounted on an electronic card. The electronic component is assumed dissipating low heat power, as such, air forced convection is still a sufficient cooling way even without fan or heat sink on the component. The measurements are given by hot and cold wires anemometers and by an InfraRed camera. The results give details of the effects of the deflection on the hydrodynamic and the thermal fields on and over the block for different inclination angles. They show that the deviation caused by the deflector may significantly enhance the heat transfer from the component. Deflection is also able to avoid local overheating of the electronic component. Optimum heat transfer rate and homogenised temperature are shown to be obtained with an inclination angle α=30°.

  17. Turbulent Flow past High Temperature Surfaces

    Science.gov (United States)

    Mehmedagic, Igbal; Thangam, Siva; Carlucci, Pasquale; Buckley, Liam; Carlucci, Donald

    2014-11-01

    Flow over high-temperature surfaces subject to wall heating is analyzed with applications to projectile design. In this study, computations are performed using an anisotropic Reynolds-stress model to study flow past surfaces that are subject to radiative flux. The model utilizes a phenomenological treatment of the energy spectrum and diffusivities of momentum and heat to include the effects of wall heat transfer and radiative exchange. The radiative transport is modeled using Eddington approximation including the weighted effect of nongrayness of the fluid. The time-averaged equations of motion and energy are solved using the modeled form of transport equations for the turbulence kinetic energy and the scalar form of turbulence dissipation with an efficient finite-volume algorithm. The model is applied for available test cases to validate its predictive capabilities for capturing the effects of wall heat transfer. Computational results are compared with experimental data available in the literature. Applications involving the design of projectiles are summarized. Funded in part by U.S. Army, ARDEC.

  18. Effectiveness of horizontal air flow fans supporting natural ventilation in a Mediterranean multi-span greenhouse

    Directory of Open Access Journals (Sweden)

    Alejandro López

    2013-08-01

    Full Text Available Natural ventilation is the most important method of climate control in Mediterranean greenhouses. In this study, the microclimate and air flow inside a Mediterranean greenhouse were evaluated by means of sonic anemometry. Experiments were carried out in conditions of moderate wind (≈ 4.0 m s-1, and at low wind speed (≈ 1.8 m s-1 the natural ventilation of the greenhouse was supplemented by two horizontal air flow fans. The greenhouse is equipped with a single roof vent opening to the windward side and two side vents, the windward one being blocked by another greenhouse close to it, while the leeward one is free of obstacles. When no fans are used, air enters through the roof vent and exits through both side vents, thus flowing contrary to the thermal effect which causes hot air to rise and impairing the natural ventilation of the greenhouse. Using fans inside the greenhouse helps the air to circulate and mix, giving rise to a more homogeneous inside temperature and increasing the average value of normalized air velocity by 365 %. These fans also increase the average values of kinetic turbulence energy inside the greenhouse by 550 % compared to conditions of natural ventilation. As the fans are placed 4 m away from the side vents, their effect on the entrance of outside air is insufficient and they do not help to reduce the inside temperature on hot days with little wind. It is therefore recommended to place the fans closer to the side vents to allow an additional increase of the air exchange rate of greenhouses.

  19. Low-Flow Liquid Desiccant Air Conditioning: General Guidance and Site Considerations

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.

    2014-09-01

    Dehumidification or latent cooling in buildings is an area of growing interest that has been identified as needing more research and improved technologies for higher performance. Heating, ventilating, and air-conditioning (HVAC) systems typically expend excessive energy by using overcool-and-reheat strategies to dehumidify buildings. These systems first overcool ventilation air to remove moisture and then reheat the air to meet comfort requirements. Another common strategy incorporates solid desiccant rotors that remove moisture from the air more efficiently; however, these systems increase fan energy consumption because of the high airside pressure drop of solid desiccant rotors and can add heat of absorption to the ventilation air. Alternatively, liquid desiccant air-conditioning (LDAC) technology provides an innovative dehumidification solution that: (1) eliminates the need for overcooling and reheating from traditional cooling systems; and (2) avoids the increased fan energy and air heating from solid desiccant rotor systems.

  20. High-voltage air-core pulse transformers

    Energy Technology Data Exchange (ETDEWEB)

    Rohwein, G. J.

    1981-01-01

    General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

  1. Analysis of flow maldistribution in fin-and-tube evaporators for residential air-conditioning systems

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl

    validated and showed that a slip flow model need be used. A test case 8.8 kW residential air-conditioning system with R410A as refrigerant is chosen as baseline for the numerical investigations, and the simulations are performed at standard rating conditions from ANSI/AHRI Standard 210/240 (2008...... cases are standard tube circuitry designs and these results are thus tube circuitry specific. In addition, a novel method of compensating flow maldistribution is analyzed, i.e. the discontinuous liquid injection principle. The method is based upon the recently developed EcoFlowTM valve by Danfoss A...

  2. Air Distribution in a Room and Design Considerations of Mixing Ventilation by Flow Elements

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Pedersen, D. N.

    2001-01-01

    The paper shows detailed measurements of the air distribution in a room ventilated by mixing ventilation according to the specifications given by the International Energy Agency work. (Energy Conservation in Buildings and Community Systems Programme, Annex 20). It describes a number of flow...... elements and how they are used as design tools. The flow elements are the throw of an isothermal jet and the change in jet velocity when the jet moves from the upper to the lower part of the room. A third flow element is the penetration length of a non-isothermal wall jet....

  3. FLOW CURVES OF AN ADSORBED PROTEIN LAYER AT THE SALIVA-AIR INTERFACE

    NARCIS (Netherlands)

    HOLTERMAN, HJ; SGRAVENMADE, EJ; WATERMAN, HA; BLOM, C; Mellema, J.

    1990-01-01

    At the air-liquid interface of human saliva a protein layer is absorbed. An apparatus is described with which a flow curve of this layer was measured. In the majority of samples the viscosity of the surface layer changed gradually and could be described by a power-law dependence on the shear rate. T

  4. Stratified Flow in a Room with Displacement Ventilation and Wall-Mounted Air Terminal devices

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper describes experiments with wall-mounted air terminal devices. The stratified flow in the room is analyzed, and the influence of stratification and the influence of room dimensions on the velocity level and on the length scale are proved. The velocity level in the occupied zone can be d...

  5. Air-flow resistances of silicone rubber voice prostheses after formation of bacterial and fungal biofilms

    NARCIS (Netherlands)

    Elving, GJ; van der Mei, HC; Busscher, HJ; van Weissenbruch, R; Albers, FWJ

    Laryngectomized patients use silicone rubber voice prostheses to rehabilitate their voice. However, biofilm formation limits the lifetime of voice prostheses by causing leakage or an increased air-flow resistance and the prosthesis has to be replaced. To determine which bacterial or yeast strains,

  6. Compensation of flow maldistribution in fin-and-tube evaporators for residential air-conditioning

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian;

    2011-01-01

    Compensation of flow maldistribution in multi-channel fin-and-tube evaporators for residential air-conditioning is investigated by numerical modeling. The considered sources of maldistribution are distribution of the liquid and vapor phases in the distributor and non-uniform airflow distribution...

  7. Air Distribution in Rooms with Ceiling-mounted Obstacles and Three-Dimensional Isothermal Flow

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Evensen, Louis; Grabau, Peter;

    The air supply openings in ventilated rooms are often placed close to the ceiling. A recirculating flow is generated in the room, and the region between the ceiling and the occupied zone serves as an entrainment and velocity decay area for the wall jets. Ceiling-mounted obstacles may disturb...

  8. Air purification in a reverse-flow reactor: Model simulations vs. experiments

    NARCIS (Netherlands)

    Beld, van de L.; Westerterp, K.R.

    1996-01-01

    The behavior of a reverse-flow reactor was studied for the purification of polluted air by catalytic combustion. A heterogeneous one-dimensional model was extended with a heat balance for the reactor wall. An overall heat transport term is included to account for the small heat losses in radial dire

  9. Wind Tunnel Evaluation of Vegetative Buffer Effects on Air Flow near Swine Production Facilities

    Science.gov (United States)

    Increasing concerns about generation and transport of swine odor constituents have substantiated wind tunnel simulation studies on air flow dynamics near swine production facilities. A possible odor mitigation strategy is a forest vegetative buffer as a windbreak barrier near swine facilities becaus...

  10. Spatiotemporally resolved characteristics of a gliding arc discharge in a turbulent air flow at atmospheric pressure

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas

    2017-01-01

    A gliding arc discharge was generated in a turbulent air flow at atmospheric pressure driven by a 35 kHz alternating current (AC) electric power. The spatiotemporally resolved characteristics of the gliding arc discharge, including glow-type discharges, spark-type discharges, short-cutting events...

  11. NUMERICAL STUDY ON AIR FLOW AROUND AN OPENING WITH LARGE EDDY SIMULATION

    Institute of Scientific and Technical Information of China (English)

    Fan Hong-ming; Ren Hong-ze; Li Xian-ting; Yi Jiang

    2003-01-01

    Jet characteristics of air supply opening in a ventilating or an air-conditioning system is primarily decided by the folw state in the duct connected to the opening. It is valuable to study the opening jet characteristics and the flow state in a duct. In this study, the Large Eddy Simulation (LES) technique combined with the Tarlor-Galerkin Finite Element Method (FEM) in Computational Fluid Dynamics (CFD) was applied to the problem. The 3-D flow fields in ducts around air supply opening under typical conditions were investigated by numerical simulation as well as experimental measurements. Numerical results agree well with the available experimental data. It indicates that the LES method is available under the conditions with complicated boundaries and inner accompanied by anisotropic large-scale eddies, and it is credible to predict the jet deflection characteristics around an opening.

  12. Airborne nanoparticle exposures while using constant-flow, constant-velocity, and air-curtain-isolated fume hoods.

    Science.gov (United States)

    Tsai, Su-Jung Candace; Huang, Rong Fung; Ellenbecker, Michael J

    2010-01-01

    Tsai et al. (Airborne nanoparticle exposures associated with the manual handling of nanoalumina and nanosilver in fume hoods. J Nanopart Res 2009; 11: 147-61) found that the handling of dry nanoalumina and nanosilver inside laboratory fume hoods can cause a significant release of airborne nanoparticles from the hood. Hood design affects the magnitude of release. With traditionally designed fume hoods, the airflow moves horizontally toward the hood cupboard; the turbulent airflow formed in the worker wake region interacts with the vortex in the constant-flow fume hood and this can cause nanoparticles to be carried out with the circulating airflow. Airborne particle concentrations were measured for three hood designs (constant-flow, constant-velocity, and air-curtain hoods) using manual handling of nanoalumina particles. The hood operator's airborne nanoparticle breathing zone exposure was measured over the size range from 5 nm to 20 mum. Experiments showed that the exposure magnitude for a constant-flow hood had high variability. The results for the constant-velocity hood varied by operating conditions, but were usually very low. The performance of the air-curtain hood, a new design with significantly different airflow pattern from traditional hoods, was consistent under all operating conditions and release was barely detected. Fog tests showed more intense turbulent airflow in traditional hoods and that the downward airflow from the double-layered sash to the suction slot of the air-curtain hood did not cause turbulence seen in other hoods.

  13. Electro-hydrodynamic force field and flow patterns generated by a DC corona discharge in the air

    Science.gov (United States)

    Monrolin, Nicolas; Plouraboue, Franck; Praud, Olivier

    2016-11-01

    Ionic wind refers to the electro-convection of ionised air between high voltage electrodes. Microscopic ion-neutral collisions are responsible for momentum transfer from accelerated ions, subjected to the electric field, to the neutral gas molecules resulting in a macroscopic airflow acceleration. In the past decades it has been investigated for various purposes from food drying through aerodynamic flow control and eventually laptop cooling. One consequence of air acceleration between the electrodes is thrust generation, often referred to as the Biefeld-Brown effect or electro-hydrodynamic thrust. In this experimental study, the ionic wind velocity field is measured with the PIV method. From computing the acceleration of the air we work out the electrostatic force field for various electrodes configurations. This enables an original direct evaluation of the force distribution as well as the influence of electrodes shape and position. Thrust computation based on the flow acceleration are compared with digital scale measurements. Complex flow features are highlighted such as vortex shedding, indicating that aerodynamic effects may play a significant role. Furthermore, the aerodynamic drag force exerted on the electrodes is quantified by choosing an appropriate control volume. Authors thank Region Midi-Pyrenee and CNES Launcher Directorate for financial support.

  14. The simulated air flow pattern around a moving animal transport vehicle as the basis for a prospective biosecurity risk assessment

    Directory of Open Access Journals (Sweden)

    Jens Seedorf

    2017-08-01

    Full Text Available Research that investigates bioaerosol emissions from animal transport vehicles (ATVs and their importance in the spread of harmful airborne agents while the ATVs travel on roads is limited. To investigate the dynamical behaviour of theoretically released particles from a moving ATV, the open-source computational fluid dynamics (CFD software OpenFOAM was used to calculate the external and internal air flow fields with passive and forced ventilated openings of a common ATV moving at a speed of 80 km/h. In addition to a computed flow rate of approximately 40,000 m3/h crossing the interior of the ATV, the visualization of the trajectories has demonstrated distinct patterns of the spatial distribution of potentially released bioaerosols in the vicinity of the ATV. Although the front openings show the highest air flow to the outside, the recirculations of air masses between the interior of the ATV and the atmosphere also occur, which complicate the emission and the dispersion characterizations. To specify the future emission rates of ATVs, a database of bioaerosol concentrations within the ATV is necessary in conjunction with high-performance computing resources to simulate the potential dispersion of bioaerosols in the environment.

  15. Numerical simulation of high pressure release and dispersion of hydrogen into air with real gas model

    Science.gov (United States)

    Khaksarfard, R.; Kameshki, M. R.; Paraschivoiu, M.

    2010-06-01

    Hydrogen is a renewable and clean source of energy, and it is a good replacement for the current fossil fuels. Nevertheless, hydrogen should be stored in high-pressure reservoirs to have sufficient energy. An in-house code is developed to numerically simulate the release of hydrogen from a high-pressure tank into ambient air with more accuracy. Real gas models are used to simulate the flow since high-pressure hydrogen deviates from ideal gas law. Beattie-Bridgeman and Abel Noble equations are applied as real gas equation of state. A transport equation is added to the code to calculate the concentration of the hydrogen-air mixture after release. The uniqueness of the code is to simulate hydrogen in air release with the real gas model. Initial tank pressures of up to 70 MPa are simulated.

  16. Influence of exhaled air on inhalation exposure delivered through a directed-flow nose-only exposure system.

    Science.gov (United States)

    Moss, O R; James, R A; Asgharian, B

    2006-01-01

    In order to conserve material that is available in limited quantities, "directed-flow" nose-only exposure systems have at times been run at flow rates close to the minute ventilation of the animal. Such low-flow-rate conditions can contribute to a decrease of test substance concentration in inhaled air; near the animal nose, exhaled air and the directed flow of exposure air move in opposite directions. With a Cannon "directed-flow" nose-only exposure system (Lab Products, Maywood, NJ), we investigated the extent to which exposure air plus exhaled air can be inhaled by an animal. A mathematical model and a mechanical simulation of respiration were adopted to predict for a male Fischer 344 rat the concentration of test substance in inhaled air. The mathematical model was based on the assumption of instantaneous mixing. The mechanical simulation of respiration used a Harvard respirator. When the system was operated at an exposure air flow rate greater than 2.5 times the minute ventilation of the animal, the concentration of test substance in the inhaled air was reduced by less than 10%. Under these conditions, the circular jet of air exiting the exposure air delivery tube tended to reach the animal's nose with little dispersion. For exposure air flow rates less than 2 times the minute ventilation, we predict that the interaction of exhaled air and exposure air can be minimized by proportionally reducing the delivery tube diameter. These findings should be applicable to similar "directed-flow" nose-only exposure systems.

  17. Simplified model for a ventilated glass window under forced air flow conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, K.A.R. [Depto. de Engenharia Termica e de Fluidos-FEM-UNICAMP CP: 6122 CEP 13083-970 Campinas, SP (Brazil); Henriquez, J.R. [Depto. de Eng. Mecanica-DEMEC, UFPE Av. Academico Helio Ramos, S/N CEP 50740-530, Recife, PE (Brazil)

    2006-02-01

    This paper presents a study on a ventilated window composed of two glass sheets separated by a spacing through which air is forced to flow. The proposed model is one dimensional and unsteady based upon global energy balance over the glass sheets and the flowing fluid. The external glass sheet of the cavity is subjected to variable heat flow due to the solar radiation as well as variable external ambient temperature. The exchange of radiation energy (infrared radiation) between the glass sheets is also included in the formulation. Effects of the spacing between the glass sheets, variation of the forced mass flow rate on the total heat gain and the shading coefficients are investigated. The results show that the effect of the increase of the mass flow rate is found to reduce the mean solar heat gain and the shading coefficients while the increase of the fluid entry temperature is found to deteriorate the window thermal performance. (author)

  18. Numerical simulation of gas-liquid two-phase jet flow in air-bubble generator

    Institute of Scientific and Technical Information of China (English)

    陈文义; 王静波; 姜楠; 赵斌; 王振东

    2008-01-01

    Air-bubble generator is the key part of the self-inspiration type swirl flotation machines,whose flow field structure has a great effect on flotation.The multiphase volume of fluid(VOF),standard k-ε turbulent model and the SIMPLE method were chosen to simulate the present model;the first order upwind difference scheme was utilized to perform a discrete solution for momentum equation.The distributing law of the velocity,pressure,turbulent kinetic energy of every section along the flow direction of air-bubble generator was analyzed.The results indicate that the bubbles are heavily broken up in the middle cross section of throat sect and the entrance of diffuser sect along the flow direction,and the turbulent kinetic energy of diffuser sect is larger than the entrance of throat sect and mixing chamber.

  19. Mechanical Design of a Performance Test Rig for the Turbine Air-Flow Task (TAFT)

    Science.gov (United States)

    Forbes, John C.; Xenofos, George D.; Farrow, John L.; Tyler, Tom; Williams, Robert; Sargent, Scott; Moharos, Jozsef

    2004-01-01

    To support development of the Boeing-Rocketdyne RS84 rocket engine, a full-flow, reaction turbine geometry was integrated into the NASA-MSFC turbine air-flow test facility. A mechanical design was generated which minimized the amount of new hardware while incorporating all test and instrumentation requirements. This paper provides details of the mechanical design for this Turbine Air-Flow Task (TAFT) test rig. The mechanical design process utilized for this task included the following basic stages: Conceptual Design. Preliminary Design. Detailed Design. Baseline of Design (including Configuration Control and Drawing Revision). Fabrication. Assembly. During the design process, many lessons were learned that should benefit future test rig design projects. Of primary importance are well-defined requirements early in the design process, a thorough detailed design package, and effective communication with both the customer and the fabrication contractors.

  20. FINAL REPORT on Experimental Validation of Stratified Flow Phenomena, Graphite Oxidation, and Mitigation Strategies of Air Ingress Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Chang H. Oh; Eung S. Kim; Hee C. NO; Nam Z. Cho

    2011-01-01

    The U.S. Department of Energy is performing research and development that focuses on key phenomena that are important during challenging scenarios that may occur in the Next Generation Nuclear Plant (NGNP)/Generation IV very high temperature reactor (VHTR). Phenomena Identification and Ranking studies to date have identified the air ingress event, following on the heels of a VHTR depressurization, as very important. Consequently, the development of advanced air ingress-related models and verification & validation are of very high priority for the NGNP Project. Following a loss of coolant and system depressurization incident, air ingress will occur through the break, leading to oxidation of the in-core graphite structure and fuel. This study indicates that depending on the location and the size of the pipe break, the air ingress phenomena are different. In an effort to estimate the proper safety margin, experimental data and tools, including accurate multidimensional thermal-hydraulic and reactor physics models, a burn-off model, and a fracture model are required. It will also require effective strategies to mitigate the effects of oxidation, eventually. This 3-year project (FY 2008–FY 2010) is focused on various issues related to the VHTR air-ingress accident, including (a) analytical and experimental study of air ingress caused by density-driven, stratified, countercurrent flow, (b) advanced graphite oxidation experiments, (c) experimental study of burn-off in the core bottom structures, (d) structural tests of the oxidized core bottom structures, (e) implementation of advanced models developed during the previous tasks into the GAMMA code, (f) full air ingress and oxidation mitigation analyses, (g) development of core neutronic models, (h) coupling of the core neutronic and thermal hydraulic models, and (i) verification and validation of the coupled models.

  1. Testing flow-through air samplers for use in near-field vapour drift studies by measuring pyrimethanil in air after spraying.

    Science.gov (United States)

    Geoghegan, Trudyanne S; Hageman, Kimberly J; Hewitt, Andrew J

    2014-03-01

    Pesticide volatilisation and subsequent vapour drift reduce a pesticide's efficiency and contribute to environmental contamination. High-volume air samplers (HVSs) are often used to measure pesticide concentrations in air but these samplers are expensive to purchase and require network electricity, limiting the number and type of sites where they can be deployed. The flow-through sampler (FTS) presents an opportunity to overcome these limitations. The FTS is a wind-driven passive sampler that has been developed to quantify organic contaminants in remote ecosystems. FTSs differ from other passive samplers in that they turn into the wind and use the wind to draw air through the sampling media. The main objective of this work was to evaluate the FTS in a near-field pesticide vapour drift study by comparing the concentrations of pyrimethanil in air measured using one HVS and three FTSs placed in the same location. Pyrimethanil was sprayed onto a vineyard as part of normal pest management procedures. Air samples were collected every eight hours for 48 h. The volume of air sampled by the FTSs was calculated using the measured relationship between ambient wind speed and the wind speed inside the sampler as determined with a separate wind tunnel study. The FTSs sampled 1.7 to 40.6 m(3) of air during each 8 h sampling period, depending on wind speed, whereas the mean volume sampled by the HVS was 128.7 m(3). Mean pyrimethanil concentrations ranged from 0.4 to 3.2 μg m(-3) of air. Inter-sampler reproducibility, as represented by percent relative standard deviation, for the three FTSs was ∼20%. The largest difference in FTS-derived versus HVS-derived pyrimethanil concentrations occurred during the lowest wind-speed period. During this period, it is likely that the FTS predominately acted like a traditional diffusion-based passive sampler. As indicated by both types of sampler, pyrimethanil concentrations in air changed by a factor of ∼2 during the two days after spaying

  2. Numerical Simulation and Experimental Studies of Air Treatment Process with Water Spray of One Row Counter Flow

    Institute of Scientific and Technical Information of China (English)

    倪波

    2001-01-01

    The present work is focused on heat and mass transfer in a direct evaporative air cooler of one row counter flow spray. Models of the two-phase flow in such a air treatment system have been developed. The fields of temperature and relative humidity in spray chamber, as well as the trajectories of sprayed drops have been obtained by numerical method. Experiments aiming at quantifying the system performance and its influence factors have been conducted. It indicates that the increase of air velocity and water/air ratio while the decrease of nozzle density are favorable. The performance of the system of parallel flow spray and counter flow spray have been compared by means of humidifying efficiency. Comparison between numerical simulation and experimental results demonstrate good agreement for outlet air temperature with a maximum error of 8% observed for air relative humidity.

  3. Three-Dimensional Mapping of Air Flow at an Urban Canyon Intersection

    Science.gov (United States)

    Carpentieri, Matteo; Robins, Alan G.; Baldi, Sandro

    2009-11-01

    In this experimental work both qualitative (flow visualisation) and quantitative (laser Doppler anemometry) methods were applied in a wind tunnel in order to describe the complex three-dimensional flow field in a real environment (a street canyon intersection). The main aim was an examination of the mean flow, turbulence and flow pathlines characterising a complex three-dimensional urban location. The experiments highlighted the complexity of the observed flows, particularly in the upwind region of the intersection. In this complex and realistic situation some details of the upwind flow, such as the presence of two tall towers, play an important role in defining the flow field within the intersection, particularly at roof level. This effect is likely to have a strong influence on the mass exchange mechanism between the canopy flow and the air aloft, and therefore the distribution of pollutants. This strong interaction between the flows inside and outside the urban canopy is currently neglected in most state-of-the-art local scale dispersion models.

  4. Co-current air-water flow in downward sloping pipes: Transport of capacity reducing gas pockets in wastewater mains

    NARCIS (Netherlands)

    Pothof, I.W.M.

    2011-01-01

    Air-water flow is an undesired condition in many systems for the transportation of water or wastewater. Air in storm water tunnels may get trapped and negatively affect the system. Air pockets in hydropower tunnels or sewers may cause blow-back events and inadmissible pressure spikes. Water pipes an

  5. Measurement of air distribution and void fraction of an upwards air-water flow using electrical resistance tomography and a wire-mesh sensor

    Science.gov (United States)

    Olerni, Claudio; Jia, Jiabin; Wang, Mi

    2013-03-01

    Measurements on an upwards air-water flow are reported that were obtained simultaneously with a dual-plane electrical resistance tomograph (ERT) and a wire-mesh sensor (WMS). The ultimate measurement target of both ERT and WMS is the same, the electrical conductivity of the medium. The ERT is a non-intrusive device whereas the WMS requires a net of wires that physically crosses the flow. This paper presents comparisons between the results obtained simultaneously from the ERT and the WMS for evaluation and calibration of the ERT. The length of the vertical testing pipeline section is 3 m with an internal diameter of 50 mm. Two distinct sets of air-water flow rate scenarios, bubble and slug regimes, were produced in the experiments. The fast impedance camera ERT recorded the data at an approximate time resolution of 896 frames per second (fps) per plane in contrast with the 1024 fps of the wire-mesh sensor WMS200. The set-up of the experiment was based on well established knowledge of air-water upwards flow, particularly the specific flow regimes and wall peak effects. The local air void fraction profiles and the overall air void fraction were produced from two systems to establish consistency for comparison of the data accuracy. Conventional bulk flow measurements in air mass and electromagnetic flow metering, as well as pressure and temperature, were employed, which brought the necessary calibration to the flow measurements. The results show that the profiles generated from the two systems have a certain level of inconsistency, particularly in a wall peak and a core peak from the ERT and WMS respectively, whereas the two tomography instruments achieve good agreement on the overall air void fraction for bubble flow. For slug flow, when the void fraction is over 30%, the ERT underestimates the void fraction, but a linear relation between ERT and WMS is still observed.

  6. Flow structures in a lean-premixed swirl-stabilized combustor with microjet air injection

    KAUST Repository

    LaBry, Zachary A.

    2011-01-01

    The major challenge facing the development of low-emission combustors is combustion instability. By lowering flame temperatures, lean-premixed combustion has the potential to nearly eliminate emissions of thermally generated nitric oxides, but the chamber acoustics and heat release rate are highly susceptible to coupling in ways that lead to sustained, high-amplitude pressure oscillations, known as combustion instability. At different operating conditions, different modes of instability are observed, corresponding to particular flame shapes and resonant acoustic modes. Here we show that in a swirl-stabilized combustor, these instability modes also correspond to particular interactions between the flame and the inner recirculation zone. Two stable and two unstable modes are examined. At lean equivalence ratios, a stable conical flame anchors on the upstream edge of the inner recirculation zone and extends several diameters downstream along the wall. At higher equivalence ratios, with the injection of counter-swirling microjet air flow, another stable flame is observed. This flame is anchored along the upstream edge of a stronger recirculation zone, extending less than one diameter downstream along the wall. Without the microjets, a stationary instability coupled to the 1/4 wave mode of the combustor shows weak velocity oscillations and a stable configuration of the inner and outer recirculation zones. Another instability, coupled to the 3/4 wave mode of the combustor, exhibits periodic vortex breakdown in which the core flow alternates between a columnar mode and a vortex breakdown mode. © 2010 Published by Elsevier Inc. on behalf of The Combustion Institute. All rights reserved.

  7. High-Speed Rail & Air Transport Competition

    NARCIS (Netherlands)

    Adler, Nicole; Nash, Chris; Pels, Eric

    2008-01-01

    This paper develops a methodology to assess transport infrastructure investments and their effects on a Nash equilibria taking into account competition between multiple privatized transport operator types. The operators, including high-speed rail, hub and spoke legacy airlines and low cost carriers,

  8. Internal air flow analysis of a bladeless micro aerial vehicle hemisphere body using computational fluid dynamic

    Energy Technology Data Exchange (ETDEWEB)

    Othman, M. N. K., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Zuradzman, M. Razlan, E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Hazry, D., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Khairunizam, Wan, E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Shahriman, A. B., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Yaacob, S., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Ahmed, S. Faiz, E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my [Centre of Excellence for Unmanned Aerial Systems, Universiti Malaysia Perlis, 01000 Kangar, Perlis (Malaysia); and others

    2014-12-04

    This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors and the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.

  9. Computing Isentropic Flow Properties of Air/R-134a Mixtures

    Science.gov (United States)

    Kvaternik, Ray

    2006-01-01

    MACHRK is a computer program that calculates isentropic flow properties of mixtures of air and refrigerant R-134a (tetrafluoroethane), which are used in transonic aerodynamic testing in a wind tunnel at Langley Research Center. Given the total temperature, total pressure, static pressure, and mole fraction of R-134a in a mixture, MACHRK calculates the Mach number and the following associated flow properties: dynamic pressure, velocity, density, static temperature, speed of sound, viscosity, ratio of specific heats, Reynolds number, and Prandtl number. Real-gas effects are taken into account by treating the gases comprising the mixture as both thermally and calorically imperfect. The Redlich-Kwong equation of state for mixtures and the constant-pressure ideal heat-capacity equation for the mixture are used in combination with the departure- function approach of thermodynamics to obtain the equations for computing the flow properties. In addition to the aforementioned calculations for air/R-134a mixtures, a research version of MACHRK can perform the corresponding calculations for mixtures of air and R-12 (dichlorodifluoromethane) and for air/SF6 mixtures. [R-12 was replaced by R-134a because of environmental concerns. SF6 has been considered for use in increasing the Reynolds-number range.

  10. CFD analyses of flow structures in air-ingress and rod bundle problems

    Science.gov (United States)

    Wei, Hong-Chan

    Two topics from nuclear engineering field are included in this dissertation. One study is the air-ingress phenomenon during a loss of coolant accident (LOCA) scenario, and the other is a 5-by-5 bundle assembly with a PWR design. The objectives were to investigate the Kelvin-Helmholtz instability of the gravity-driven stratified flows inside a coaxial pipe and the effects caused by two types of spacers at the downstream of the rod bundle. Richardson extrapolation was used for the grid independent study. The simulation results show good agreements with the experiments. Wavelet analysis and Proper Orthogonal Decomposition (POD) were used to study the flow behaviors and flow patterns. For the air-ingress phenomenon, Brunt-Vaisala frequency, or buoyancy frequency, predicts a frequency of 2.34 Hz; this is confirmed by the dominant frequency of 2.4 Hz obtained from the wavelet analysis between times 1.2 s and 1.85 s. For the rod bundle study, the dominant frequency at the center of the subchannel was determined to be 2.4 Hz with a secondary dominant frequency of 4 Hz and a much minor frequency of 6 Hz. Generally, wavelet analysis has much better performance than POD, in the air-ingress phenomenon, for a strongly transient scenario; they are both appropriate for the rod bundle study. Based on this study, when the fluid pair in a real condition is used, the time which air intrudes into the reactor is predictable.

  11. Air-bubbling, hollow-fiber reactor with cell bleeding and cross-flow filtration.

    Science.gov (United States)

    Nishii, K; Sode, K; Karube, I

    1990-05-01

    Continuous asymmetric reduction of dyhydrooxoisophorone (DOIP) to 4-hydroxy-2,2,6-trimethylcyclo-hexanone (4-HTMCH) was achieved by a thermophilic bacterium Bacillus stearothermophilus NK86-0151. Three reactors were used: an air-bubbling hollow-fiber reactor with cell bleeding and cross-flow filtration, an air-lift reactor, and a CSTR with PAA immobilized cells. The maximum cell concentration of 11.1 g dry wt L(-1) was obtained in an air-bubbling hollow-fiber reactor, while in the other reactors the cell densities were between 3.5 and 4.1 g dry wt L(-1) The optimum bleed ratio was 0.1 at the dilution rate 0.3 h(-1) in the hollow-fiber reactor. The highest viable cell concentration was maintained in the dilution range of 0.4-0.7 h(-1) by a combination of proper cell bleeding and cross-flow filtration. The maximum volumetric productivity of 4-HTMCH reached 826 mg L(-1) h(-1) at the dilution rate 0.54 h(-1). This value was 4 and 2 times higher than those in the air-lift reactor and CSTR, respectively. The increasing viable cell concentration increased the volumetric productivity of 4-HTMCH. A cell free product solution was continuously obtained by cross-flow filtration.

  12. Internal air flow analysis of a bladeless micro aerial vehicle hemisphere body using computational fluid dynamic

    Science.gov (United States)

    Othman, M. N. K.; Zuradzman, M. Razlan; Hazry, D.; Khairunizam, Wan; Shahriman, A. B.; Yaacob, S.; Ahmed, S. Faiz; Hussain, Abadalsalam T.

    2014-12-01

    This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors and the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.

  13. Air flows in big cavity, building aeraulics; ecoulements de l`air en grande cavite, aeraulique des batiments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This workshop day was jointly organized by the French society of thermal engineers (SFT) and the university group of thermal engineers (GUT). This compilation of proceedings comprises 10 papers dealing with: the use of zonal models for the prediction of the temperature field inside buildings; prediction of the natural ventilation air renewing inside a cavity with a single big aperture using a finite-difference code; experimental validation of the EOL-3D code in industrial ventilating; precise numerical modeling of flows inside ventilated or not-ventilated cavities with pollutant species using a finite difference field code; building aeraulics at Electricite de France (EdF): from the basic research to field applications; experimental study of a heavy vertical jet, influence on the thermal comfort inside a air-conditioned room; study of non-isothermal 3-D free jets: comparison of measurement results with field code modeling; natural air-conditioning of accommodations in humid tropical climate; natural ventilating in humid tropical climate, proposition for a method of evaluation of the velocity coefficients; comparison between measurements and calculations concerning the atmosphere of occupied rooms. (J.S.)

  14. CFD model of air movement in ventilated façade: comparison between natural and forced air flow

    Directory of Open Access Journals (Sweden)

    Miguel Mora Pérez, Gonzalo López Patiño, P. Amparo López Jiménez

    2013-01-01

    Full Text Available This study describes computational fluid dynamics (CFD modeling of ventilated façade. Ventilated façades are normal façade but it has an extra channel between the concrete wall and the (double skin façade. Several studies found in the literature are carried out with CFD simulations about the behavior of the thermodynamic phenomena of the double skin façades systems. These studies conclude that the presence of the air gap in the ventilated façade affects the temperature in the building skin, causing a cooling effect, at least in low-rise buildings. One of the most important factors affecting the thermal effects of ventilated façades is the wind velocity. In this contribution, a CFD analysis applied on two different velocity assumptions for air movement in the air gap of a ventilated façade is presented. A comparison is proposed considering natural wind induced velocity with forced fan induced velocity in the gap. Finally, comparing temperatures in the building skin, the differences between both solutions are described determining that, related to the considered boundary conditions, there is a maximum height in which the thermal effect of the induced flow is significantly observed.

  15. Steady film flow over 2D topography with air inclusion formed inside the trench

    Science.gov (United States)

    Tsamopoulos, John; Varchanis, Stylianos; Dimakopoulos, Yannis

    2016-11-01

    Liquid film flow along an inclined, solid substrate featuring periodic rectangular trenches may either completely wet the trench floor (Wenzel state) or pin on the entrance and exit corners of the trench (Cassie state) or assume any other configuration in between these two extremes. In the intermediate cases a second gas-liquid interface inside the trench is formed, which adheres to the walls of the trench forming two three-phase contact lines, and encloses a different amount of air under different physical conditions. The Galerkin finite element method is used to solve the Navier-Stokes equations in a physical domain, which is adaptively re-meshed. Multiple steady solutions, connected by turning points and transcritical bifurcations as well as isolated solution branches, are revealed by pseudo arc-length continuation. Two possible cases of a single air inclusion inside the trench are examined. The penetration of the liquid inside the trench is enhanced primarily by increasing either the wettability of the substrate or the capillarity or by decreasing the flow rate. Flow hysteresis may occur when the liquid does not penetrate deep enough inside the trench leading to different flow patterns. The interplay of inertia, viscous, gravity and capillary forces along with substrate wettability determines the volume of the air encapsulated in the trench and the extent of free surface deformation. GSRT of Greece via the program "Excellence" and the LIMMAT foundation.

  16. Transonic flow of moist air around an NACA 0012 airfoil with non-equilibrium condensation

    Institute of Scientific and Technical Information of China (English)

    LI Liang; SUN Xiuling; FENG Zhenping; LI Guojun

    2005-01-01

    The classical condensation model of water vapor is coupled with the Euler equations to calculate transonic flows of moist air with non-equilibrium condensation. By means of this model, numerical computations are implemented to investigate the aerodynamic characteristics of an NACA 0012 airfoil in transonic flows of moist air at various angles of attack and relative humidities, and the results are compared with those in dry air flows. For different angles of attack considered at 50 % relative humidity, the lift decreases 30 % -40 %.The pressure drag increases when the angle of attack is smaller than 1.4° and decreases when higher than 1.4°. At zero angle of attack,with the relative humidity rising from zero to 90 %, the pressure drag increases exponentially. At 90 % relative humidity, the pressure drag increases 160 %, and self-oscillation takes place periodically and alternately over the upper and lower surfaces of the airfoil. The oscillation is caused by the interactions of local supersonic flow and heat release in the condensation process.

  17. An application of computational fluid mechanics to the air flow in an infant incubator.

    Science.gov (United States)

    Yamaguchi, T; Hanai, S; Horio, H; Hasegawa, T

    1992-01-01

    An application of the computational fluid mechanical method to the air flow in a two-dimensional model of an infant incubator was described. The air flow in a numerical model was simulated and the Navier-Stokes equations were directly solved using a finite-volume method incorporating a body-fitted coordinate system on a mini-supercomputer. The model was based on a real infant incubator, slightly simplified for the sake of computing speed, and included a model of a baby. The number of computation grids was 101 x 61 = 6161. The calculation was carried out under the condition of unsteady, starting airflow and the results were examined by the means of color graphics animation. There were several very large scale eddies in the incubator free space, and their global structure did not show strong changes once they were established. Although the global structure did not change, small scale eddies were shown to be produced around the air inlet and convected down through the free space of the incubator. From these results, we believe that assuming steady and uniform flow in the incubator may not always be relevant when considering heat loss of a baby in an incubator. The steady and uniform flow has been previously assumed either implicitly or explicitly by most of the authors.

  18. Preliminary design study of a quiet, high flow fan (QHF) stage. [turbofans - quiet engine program

    Science.gov (United States)

    Walker, C. L.; Kisner, L. S.; Delaney, R. A.; Beguhn, A. A.; Frye, D. E.

    1974-01-01

    Concepts selected to reduce fan generated noise in a turbofan are presented. Near-sonic flow at the fan inlet to reduce upstream propagated noise and the use of long-chord vanes to reduce downstream noise is discussed. The near-sonic condition at the rotor inlet plane was achieved by designing for high specific mass flow and by maintaining the high flow at reduced power by variable stators and variable fan exhaust nozzle. The long-chord vanes reduce response to unsteady flow. The acoustic design showed that long-chord stators would significantly reduce turbofan source noise and that other stator design parameters have no appreciable effect on noise for the spacing and chord length of the turbofan design. Four rig flow paths studied in the aerodynamic preliminary design are discussed. Noise prediction results indicate that a turbofan powered aircraft would be under federal air regulations levels without any acoustic treatment.

  19. Flow “Fine” Synthesis: High Yielding and Selective Organic Synthesis by Flow Methods

    Science.gov (United States)

    2015-01-01

    Abstract The concept of flow “fine” synthesis, that is, high yielding and selective organic synthesis by flow methods, is described. Some examples of flow “fine” synthesis of natural products and APIs are discussed. Flow methods have several advantages over batch methods in terms of environmental compatibility, efficiency, and safety. However, synthesis by flow methods is more difficult than synthesis by batch methods. Indeed, it has been considered that synthesis by flow methods can be applicable for the production of simple gasses but that it is difficult to apply to the synthesis of complex molecules such as natural products and APIs. Therefore, organic synthesis of such complex molecules has been conducted by batch methods. On the other hand, syntheses and reactions that attain high yields and high selectivities by flow methods are increasingly reported. Flow methods are leading candidates for the next generation of manufacturing methods that can mitigate environmental concerns toward sustainable society. PMID:26337828

  20. Numerical Simulation and Experimental Studies of Air Treatment Process with Water Spray of One Row Parallel Flow

    Institute of Scientific and Technical Information of China (English)

    倪波

    2001-01-01

    The main purpose of the present work is to make a further insight into the procedure of heat and mass transfer between water droplets sprayed and air stream in a direct evaporative air cooler used in air-conditioning system in textile mills. The thermodynamic models of the two-phase flow in such a air treatment system have been developed for one row parallel flow spray.The fields of temperature and relative humidity in spraylchamber, as well as the trajectories of sprayed drops have been obtained by calculation. A series of experiment aiming at quantifying the system performance and its influence factors have been conducted. It indicates that the increases of air velocity and water/air ratio while the decrease of nozzle density are favorable. Finally, the comparison between numerical simulation and experimental results have been carried out. Good agreements have been found for outlet air temperaturewhile a maximum error of 10% has been observed for air relative humidity.

  1. Countercurrent Air-Water Flow in a Scale-Down Model of a Pressurizer Surge Line

    Directory of Open Access Journals (Sweden)

    Takashi Futatsugi

    2012-01-01

    Full Text Available Steam generated in a reactor core and water condensed in a pressurizer form a countercurrent flow in a surge line between a hot leg and the pressurizer during reflux cooling. Characteristics of countercurrent flow limitation (CCFL in a 1/10-scale model of the surge line were measured using air and water at atmospheric pressure and room temperature. The experimental results show that CCFL takes place at three different locations, that is, at the upper junction, in the surge line, and at the lower junction, and its characteristics are governed by the most dominating flow limitation among the three. Effects of inclination angle and elbows of the surge line on CCFL characteristics were also investigated experimentally. The effects of inclination angle on CCFL depend on the flow direction, that is, the effect is large for the nearly horizontal flow and small for the vertical flow at the upper junction. The presence of elbows increases the flow limitation in the surge line, whereas the flow limitations at the upper and lower junctions do not depend on the presence of elbows.

  2. Tau Air-Showers Signature of Ultra High Energy Neutrinos

    CERN Document Server

    Fargion, D

    2001-01-01

    The discover of Ultra High Energy Neutrino of astrophysical nature may be already reached. Indeed upward and horizontal tau Air-showers emerging from the Earth crust or mountain chains offer the best and most powerful signal of Ultra High Energy UHE neutrinos nu_tau}, bar\

  3. High-temperature entrained flow gasification of biomass

    DEFF Research Database (Denmark)

    Qin, Ke; Lin, Weigang; Jensen, Peter Arendt

    2012-01-01

    Biomass (wood and straw) gasification has been studied in a laboratory scale atmospheric pressure entrained flow reactor. Effects of reaction temperature, steam/carbon molar ratio, excess air ratio, and biomass type on the solid, liquid and gas products were investigated. The biomass was completely...

  4. Holographic particle image velocimetry measurements of hairpin vortices in a subcritical air channel flow

    Science.gov (United States)

    Svizher, Alexander; Cohen, Jacob

    2006-01-01

    A holographic particle image velocimetry (HPIV) system is employed to study the evolution of coherent structures artificially generated in a plane Poiseuille air flow. As a first step the hot-wire technique and two-dimensional flow visualization are used to determine the generation conditions and dimensions of the coherent structures, their shedding frequency, trajectory, and convection velocity. Then, the HPIV method is utilized to obtain the instantaneous topology of the hairpin vortex and its associated three-dimensional distribution of the two (streamwise and spanwise) velocity components as well as the corresponding wall-normal vorticity. Finally, the experimental data are compared with results of related experimental and numerical studies. The present experimental results support the view that the generation of hairpins under various base flow conditions is governed by a basic mechanism, the important common elements of which are the shear of the base flow and an initial disturbance having a sufficiently large amplitude.

  5. Pressure Distribution Characters of Flow Field around High-Speed Train

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Based on incompressible viscous fluid Navier-Stokes equation and k-ε 2-equationsturbulent model, an investigation on 3D turbulent flow field around four kinds of train models has been made by finite element method. From the calculation, the pressure distribution characters of flow field around high-speed trains have been obtained. It is significant for strength design of the high-speed train body, for resisting wind design of the facilities beside the high-speed railways and for determining the aerodynamic force of induced air to the human body near the railways.

  6. Correlation between air flow rate and pollutant concentrations during two-stage oak log combustion in a 25 KW residential boiler

    Directory of Open Access Journals (Sweden)

    Juszczak Marek

    2016-09-01

    Full Text Available It can be expected that there is a considerable correlation between combustion air flow rate and the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas. The influence of temperature and oxygen concentration in the combustion zone on the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas, for high and low combustion air flow, was analysed. Oxygen concentration for which the concentration of carbon monoxide is the lowest was determined, as well as the mutual relation between carbon monoxide and nitrogen oxide concentration.

  7. Underground storage systems for high-pressure air and gases

    Science.gov (United States)

    Beam, B. H.; Giovannetti, A.

    1975-01-01

    This paper is a discussion of the safety and cost of underground high-pressure air and gas storage systems based on recent experience with a high-pressure air system installed at Moffett Field, California. The system described used threaded and coupled oil well casings installed vertically to a depth of 1200 ft. Maximum pressure was 3000 psi and capacity was 500,000 lb of air. A failure mode analysis is presented, and it is shown that underground storage offers advantages in avoiding catastrophic consequences from pressure vessel failure. Certain problems such as corrosion, fatigue, and electrolysis are discussed in terms of the economic life of such vessels. A cost analysis shows that where favorable drilling conditions exist, the cost of underground high-pressure storage is approximately one-quarter that of equivalent aboveground storage.

  8. High Frame Rate Synthetic Aperture 3D Vector Flow Imaging

    DEFF Research Database (Denmark)

    Villagómez Hoyos, Carlos Armando; Holbek, Simon; Stuart, Matthias Bo

    2016-01-01

    3-D blood flow quantification with high spatial and temporal resolution would strongly benefit clinical research on cardiovascular pathologies. Ultrasonic velocity techniques are known for their ability to measure blood flow with high precision at high spatial and temporal resolution. However......, current volumetric ultrasonic flow methods are limited to one velocity component or restricted to a reduced field of view (FOV), e.g. fixed imaging planes, in exchange for higher temporal resolutions. To solve these problems, a previously proposed accurate 2-D high frame rate vector flow imaging (VFI......) technique is extended to estimate the 3-D velocity components inside a volume at high temporal resolutions (

  9. Air flow and pollution in a real, heterogeneous urban street canyon: A field and laboratory study

    Science.gov (United States)

    Karra, Styliani; Malki-Epshtein, Liora; Neophytou, Marina K.-A.

    2017-09-01

    In this work we investigate the influence of real world conditions, including heterogeneity and natural variability of background wind, on the air flow and pollutant concentrations in a heterogeneous urban street canyon using both a series of field measurements and controlled laboratory experiments. Field measurements of wind velocities and Carbon Monoxide (CO) concentrations were taken under field conditions in a heterogeneous street in a city centre at several cross-sections along the length of the street (each cross-section being of different aspect ratio). The real field background wind was in fact observed to be highly variable and thus different Intensive Observation Periods (IOPs) represented by a different mean wind velocity and different wind variability were defined. Observed pollution concentrations reveal high sensitivity to local parameters: there is a bias towards the side closer to the traffic lane; higher concentrations are found in the centre of the street as compared to cross-sections closer to the junctions; higher concentrations are found at 1.5 height from the ground than at 2.5 m height, all of which are of concern regarding pedestrian exposure to traffic-related pollution. A physical model of the same street was produced for the purpose of laboratory experiments, making some geometrical simplifications of complex volumes and extrusions. The physical model was tested in an Atmospheric Boundary Layer water channel, using simultaneously Particle Image Velocimetry (PIV) and Planar Laser Induced Fluorescence (PLIF), for flow visualisation as well as for quantitative measurement of concentrations and flow velocities. The wind field conditions were represented by a steady mean approach velocity in the laboratory simulation (essentially representing periods of near-zero wind variability). The laboratory investigations showed a clear sensitivity of the resulting flow field to the local geometry and substantial three-dimensional flow patterns were

  10. Study of air flow and temperature distribution in ship's crew cabins

    Energy Technology Data Exchange (ETDEWEB)

    Elsafty, A.F. [Arab Academy for Science and Technology and Maritime Transport, Alexandria (Egypt). Dept. of Mechanical and Marine Engineering; Ali, A.A.; Nasr, A.N. [Arab Academy for Science and Technology and Maritime Transport, Alexandria (Egypt). Dept. of Marine Engineering Technology

    2007-07-01

    Because of low internal heights in ship's crew cabins, the supplied air is directed to the persons at low mixing ratios. However, this does not allow the mixing process between the supplied air and the indoor air to be completed before the air enters human lungs. This paper presented an experimental and numerical simulation study that used computational fluid dynamics (CFD) to investigate the effect of the air supply location on thermal air diffusion in the ship's crew cabins space. The paper presented the results in terms of air diffusion performance index. The paper presented the CFD model, including selected space configurations; CFD simulation; boundary conditions; and CFD results. The CFD airflow simulation programs CFD were utilized to calculate the spatial distribution of temperature and velocity. The study focused on the typical Middle East region working vessel under thermal and boundary conditions including the high cooling load used in this region. Experimental data were also introduced to verify the CFD results package. It was concluded that the supply should be located near the high sidewall of the cabin. This gives better air distribution inside the space rather than the center of the room. 5 refs., 1 tab., 6 figs.

  11. Sensitivity study of poisson corruption in tomographic measurements for air-water flows

    Energy Technology Data Exchange (ETDEWEB)

    Munshi, P. (Fraunhofer Institute for Nondestructive Testing, Saarbrucken (Germany)); Vaidya, M.S. (Indian Institute of Technology, Kanpur (India))

    1993-01-01

    An application of computerized tomography (CT) for measuring void fraction profiles in two-phase air-water flows was reported earlier. Those attempts involved some special radial methods for tomographic reconstruction and the popular convolution backprojection (CBP) method. The CBP method is capable of reconstructing void profiles for nonsymmetric flows also. In this paper, we investigate the effect of corrupted CT data for gamma-ray sources and aCBP algorithm. The corruption in such a case is due to the statistical (Poisson) nature of the source.

  12. Compensation of flow maldistribution in fin-and-tube evaporators for residential air-conditioning

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian

    2011-01-01

    Compensation of flow maldistribution in multi-channel fin-and-tube evaporators for residential air-conditioning is investigated by numerical modeling. The considered sources of maldistribution are distribution of the liquid and vapor phases in the distributor and non-uniform airflow distribution....... Fin-and-tube heat exchangers usually have a predefined circuitry, however, the evaporator model is simplified to have straight tubes, in order to perform a generic investigation. The compensation of flow maldistribution is performed by control of the superheat in the individual channels. Furthermore...

  13. Flammability limits in flowing ethene-air-nitrogen mixtures: an experimental study

    OpenAIRE

    Bolk, J.W.; Siccama, N.B.; Westerterp, K.R.

    1996-01-01

    A large pilot plant was constructed to study the upper flammability limit of ethene-air-nitrogen mixtures under conditions of flow. The gas mixtures flowed through an explosion tube with a length of 3.0 m and a diameter of 21 mm. An electrically heated wire was used as ignition source. Experiments were performed at pressures of 5 and 10 bar, with gas temperatures between 25 and 300 °C and with the wire fixed horizontally and vertically. Three different phenomena are observed: negligible react...

  14. Real gas flows with high velocities

    CERN Document Server

    Lunev, Vladimir V

    2009-01-01

    Gasdynamic Model and Equations Outline of the Gasdynamic Model Basic Equations and Postulates Equations of State Kinetic Theory Second Law of Thermodynamics Speed of Sound Integral Equations of Motion Kinematics of Fluid Media Differential Equations of Gasdynamics Rheological Model Initial and Boundary Conditions Similarity and Modeling in Gasdynamics Euler Equations Navier-Stokes Equations Turbulent Flows Viscous and Inviscid Flow Models Inviscid Gasdynamics Stream Function, Potential,

  15. Thermography of volcanic areas on Piton de la Fournaise, Reunion Island : Mapping surface properties and possible detection of convective air flow within volcanic debris

    Science.gov (United States)

    Antoine, R.; Baratoux, D.; Rabinowicz, M.; Saracco, G.; Bachelery, P.; Staudacher, T.; Fontaine, F.

    2007-12-01

    We report on the detection of air convection in a couple of quasi circular cavities forming the 300 years old volcanically inactive cone of Formica Leo (Piton de la Fournaise, Reunion Island) [1]. Infrared thermal images of the cone have been acquired in 2006 from a hand held camera at regular time interval during a complete diurnal cycle. During night and dawn, the data display hot rims and cold centers. Both the conductivity contrasts of the highly porous soils filling the cavities and their 30° slopes are unable to explain the systematic rim to center temperature drop. Accordingly, this signal could be attributed to an air convection dipping inside the highly porous material at the center of each cavity, then flowing upslope along the base of the soil layer, before exiting it along the rims. Anemometrical and electrical data acquired in 2007 allow for the first time the direct detection of this air flow on the field: dipping gas velocities are measured at the center of the cone and self-potentials anomalies [2] generated by the humid air flow in the porous medium are detected. To quantify this process, we present 2D/3D numerical models of air convection in a sloped volcanic soil with a surface temperature evolving between day and night and taking into account electrical phenomena created by the air flow. At this present stage, this work constitutes a first step to investigate the deep structure of the active caldera of Bory-Dolomieu. The detection of the air flow at the surface could be of paramount importance for the understanding of volcanic hazards of the Reunion volcano. [1] Antoine et. al, submitted to G-Cubed [2] Darnet, PhD, Université Louis Pasteur (2003)

  16. In situ secondary organic aerosol formation from ambient pine forest air using an oxidation flow reactor

    Directory of Open Access Journals (Sweden)

    B. B. Palm

    2015-11-01

    Full Text Available Ambient air was oxidized by OH radicals in an oxidation flow reactor (OFR located in a montane pine forest during the BEACHON-RoMBAS campaign to study biogenic secondary organic aerosol (SOA formation and aging. High OH concentrations and short residence times allowed for semi-continuous cycling through a large range of OH exposures ranging from hours to weeks of equivalent (eq. atmospheric aging. A simple model is derived and used to account for the relative time scales of condensation of low volatility organic compounds (LVOCs onto particles, condensational loss to the walls, and further reaction to produce volatile, non-condensing fragmentation products. More SOA production was observed in the OFR at nighttime (average 4 μg m-3 when LVOC fate corrected compared to daytime (average 1 μg m-3 when LVOC fate corrected, with maximum formation observed at 0.4–1.5 eq. days of photochemical aging. SOA formation followed a similar diurnal pattern to monoterpenes, sesquiterpenes, and toluene + p-cymene concentrations, including a substantial increase just after sunrise at 07:00 LT. Higher photochemical aging (> 10 eq. days led to a decrease in new SOA formation and a loss of preexisting OA due to heterogeneous oxidation followed by fragmentation and volatilization. When comparing two different commonly used methods of OH production in OFRs (OFR185 and OFR254, similar amounts of SOA formation were observed. We recommend the OFR185 mode for future forest studies. Concurrent gas-phase measurements of air after OH oxidation illustrate the decay of primary VOCs, production of small oxidized organic compounds, and net production at lower ages followed by net consumption of terpenoid oxidation products as photochemical age increased. New particle formation was observed in the reactor after oxidation, especially during times when precursor gas concentrations and SOA formation were largest. Approximately 6 times more SOA was formed in the reactor from OH

  17. Model Reference Adaptive Control of the Air Flow Rate of Centrifugal Compressor Using State Space Method

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jaeyoung; Jung, Mooncheong; Yu, Sangseok [Chungnam Nat’l Univ., Daejeon (Korea, Republic of); Yi, Sun [North Carolina A and T State Univ., Raleigh (United States)

    2016-08-15

    In this study, a model reference adaptive controller is developed to regulate the outlet air flow rate of centrifugal compressor for automotive supercharger. The centrifugal compressor is developed using the analytical based method to predict the transient behavior of operating and the designed model is validated with experimental data to confirm the system accuracy. The model reference adaptive control structure consists of a compressor model and a MRAC(model reference adaptive control) mechanism. The feedback control do not robust with variation of system parameter but the applied adaptive control is robust even if the system parameter is changed. As a result, the MRAC was regulated to reference air flow rate. Also MRAC was found to be more robust control compared with the feedback control even if the system parameter is changed.

  18. Drag Reduction of Turbulence Air Channel Flow with Distributed Micro Sensors and Actuators

    Science.gov (United States)

    Yoshino, Takashi; Suzuki, Yuji; Kasagi, Nobuhide

    A prototype system for feedback control of wall turbulence is developed, and its performance is evaluated in a physical experiment. Arrayed micro hot-film sensors with a spanwise spacing of 1 mm are employed for the measurement of streamwise shear stress fluctuations, while arrayed magnetic actuators of 2.4 mm in spanwise width are used to introduce control input through wall deformation. A digital signal processor with a time delay of 0.1 ms is employed to drive the actuators based on the sensor signals. The driving voltage of each actuator is determined with a linear combination of the wall shear stress fluctuations at three sensors located upstream of the actuator, and a noise-tolerant genetic algorithm is employed to optimize the control parameters. Feedback control experiments are conducted in a fully-developed turbulent air channel flow at the Reynolds number of Reτ=300. It is found that about 6% drag reduction has been achieved in a physical experiment for the first time. Through turbulent statistics measurements with LDV, it is also found that the Reynolds shear stress close to the wall is decreased by the present control scheme. A conditional average of a DNS database is also made to extract coherent structures associated with the present control input. It is shown that the wall-deformation actuators induce a wall-normal velocity away from the wall when the high-speed region is located above the actuator.

  19. Gas phase dispersion in compost as a function of different water contents and air flow rates

    Science.gov (United States)

    Sharma, Prabhakar; Poulsen, Tjalfe G.

    2009-07-01

    Gas phase dispersion in a natural porous medium (yard waste compost) was investigated as a function of gas flow velocity and compost volumetric water content using oxygen and nitrogen as tracer gases. The compost was chosen because it has a very wide water content range and because it represents a wide range of porous media, including soils and biofilter media. Column breakthrough curves for oxygen and nitrogen were measured at relatively low pore gas velocities, corresponding to those observed in for instance soil vapor extraction systems or biofilters for air cleaning at biogas plants or composting facilities. Total gas mechanical dispersion-molecular diffusion coefficients were fitted from the breakthrough curves using a one-dimensional numerical solution to the advection-dispersion equation and used to determine gas dispersivities at different volumetric gas contents. The results showed that gas mechanical dispersion dominated over molecular diffusion with mechanical dispersion for all water contents and pore gas velocities investigated. Importance of mechanical dispersion increased with increasing pore gas velocity and compost water content. The results further showed that gas dispersivity was relatively constant at high values of compost gas-filled porosity but increased with decreasing gas-filled porosity at lower values of gas-filled porosity. Results finally showed that measurement uncertainty in gas dispersivity is generally highest at low values of pore gas velocity.

  20. High Performance Cathodes for Li-Air Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Yangchuan

    2013-08-22

    The overall objective of this project was to develop and fabricate a multifunctional cathode with high activities in acidic electrolytes for the oxygen reduction and evolution reactions for Li-air batteries. It should enable the development of Li-air batteries that operate on hybrid electrolytes, with acidic catholytes in particular. The use of hybrid electrolytes eliminates the problems of lithium reaction with water and of lithium oxide deposition in the cathode with sole organic electrolytes. The use of acid electrolytes can eliminate carbonate formation inside the cathode, making air breathing Li-air batteries viable. The tasks of the project were focused on developing hierarchical cathode structures and bifunctional catalysts. Development and testing of a prototype hybrid Li-air battery were also conducted. We succeeded in developing a hierarchical cathode structure and an effective bifunctional catalyst. We accomplished integrating the cathode with existing anode technologies and made a pouch prototype Li-air battery using sulfuric acid as catholyte. The battery cathodes contain a nanoscale multilayer structure made with carbon nanotubes and nanofibers. The structure was demonstrated to improve battery performance substantially. The bifunctional catalyst developed contains a conductive oxide support with ultra-low loading of platinum and iridium oxides. The work performed in this project has been documented in seven peer reviewed journal publications, five conference presentations, and filing of two U.S. patents. Technical details have been documented in the quarterly reports to DOE during the course of the project.

  1. Compensation of flow maldistribution in fin-and-tube evaporators for residential air-conditioning

    OpenAIRE

    2011-01-01

    Compensation of flow maldistribution in multi-channel fin-and-tube evaporators for residential air-conditioning is investigated by numerical modeling. The considered sources of maldistribution are distribution of the liquid and vapor phases in the distributor and non-uniform airflow distribution. Fin-and-tube heat exchangers usually have a predefined circuitry, however, the evaporator model is simplified to have straight tubes, in order to perform a generic investigation. The compensation of ...

  2. Study of Mouthguard Design for Endurance and Air-Flow Intake

    Science.gov (United States)

    Zaman, I.; Rozlan, S. A. M.; Manshoor, B.; Ngali, M. Z.; Khalid, A.; Amin, N. A. M.

    2017-08-01

    Mouthguard is one of the important device for athletes. Wearing a mouthguard is a must to prevent them from any orofacial injuries occurs during their sport activities. Therefore, to make sure it is safe and comfort, a study on the mouthguard design is carried out to investigate the performance of the mouthguard, in term of stress distribution and air flow path by improving the pressure difference between ambient and the oral cavity pressure. A preliminary design has been study to simulate its total deformation and stress, in terms of Von Mises Stress by using ANSYS 15.0 Workbench. From the results, the critical parts are identified on the preliminary design and later being used to improve the design to the new one. By increasing the thickness of the preliminary design, the total deformation has been decreased for about 0.20 mm to 0.16 mm for the exerted external forces ranging from 50-500 N, whereas, for internal forces ranging from 100-600 N have reduced deformation from 0.24 mm to 1.44 mm. The simulation process is then followed by the air flow study in the oral cavity with an open mouth about 0.5 mm when the athlete is doing exercise with speed 4.43 m/s of air flow into a mouth. The finding indicates that the modified mouthguard has large value of velocity streamline compared to the preliminary design which is supported by significant pressure difference of 401.86 Pa, compared to 140.09 Pa of the preliminary design. Velocity stream line also shows that the higher speeds occur in the near mouthguard, that is, between the bottom surfaces of the mouthguard and the lower teeth. The results demonstrated that the thicker the mouthguard, the better it is for prevention but less in air flow distribution into the oral cavity.

  3. Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single-Family Homes

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, James [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Withers, Charles [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Martin, Eric [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Moyer, Neil [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2012-10-01

    This report is a revision of an earlier report titled: Measure Guideline: Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single-Family Homes. Revisions include: Information in the text box on page 1 was revised to reflect the most accurate information regarding classifications as referenced in the 2012 International Residential Code. “Measure Guideline” was dropped from the title of the report. An addition was made to the reference list.

  4. Integrated LTCC Pressure/Flow/Temperature Multisensor for Compressed Air Diagnostics†

    OpenAIRE

    Nicolas Craquelin; Aurélie Barras; Peter Ryser; Grégoire Boutinard-Rouelle; Yannick Fournier; Thomas Maeder

    2010-01-01

    We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g., as a standard electronic component would be on a printed circuit board, obviating th...

  5. A Methodology for Modeling the Flow of Military Personnel Across Air Force Active and Reserve Components

    Science.gov (United States)

    2016-01-01

    for pilots will depend on the • number of active component pilots who separate • fraction of separating pilots who affiliate with the reserve ...when tracking economic output over a period of time. GDP data were collected from the Federal Reserve Economic Data (FRED), Federal Reserve Bank of St...C O R P O R A T I O N Research Report A Methodology for Modeling the Flow of Military Personnel Across Air Force Active and Reserve Components

  6. Liquid mean velocity and turbulence in a horizontal air-water bubbly flow

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The liquid phase turbulent structure of an air-water bubbly horizontal flow in a circular pipe has been investigated experimentally. Three-dimensional measurements were implemented with two "X" type probes oriented in different planes, and local liquid-phase velocities and turbulent stresses were simultaneously obtained. Systematic measurements were conducted covering a range of local void fraction from 0 to 11.7%. The important experiment results and parametric trends are summarized and discussed.

  7. Study on the air flow field of the drawing conduit in the spunbonding process

    Directory of Open Access Journals (Sweden)

    Wu Li-Li

    2015-01-01

    Full Text Available The air flow field of the drawing conduit in the spunbonding process has a great effect on the polymer drawing, the filament diameter and orientation. A numerical simulation of the process is carried out, and the results are compared with the experimental data, showing good accuracy of the numerical prediction. This research lays an important foundation for the optimal design of the drawing conduit in the spunbonding process.

  8. Air purification in a reverse-flow reactor: Model simulations vs. experiments

    OpenAIRE

    Beld, van de, L.; Westerterp, K.R.

    1996-01-01

    The behavior of a reverse-flow reactor was studied for the purification of polluted air by catalytic combustion. A heterogeneous one-dimensional model was extended with a heat balance for the reactor wall. An overall heat transport term is included to account for the small heat losses in radial direction. The calculations are compared to experimental data without using fit parameters. The agreement between simulations and experiments is generally good. Discrepancies can be explained mainly by...

  9. Discussion on Flow-Through Phenomena in the Air Gauge Cascade

    Directory of Open Access Journals (Sweden)

    Jermak Czesław Janusz

    2017-03-01

    Full Text Available In the paper, the flow-through phenomena in the air gauge are under discussion form the thermodynamic and gasodynamic perspective. The main elements of the cascade are considered the inlet nozzle (restriction, measuring chamber and the measuring nozzle with the measuring slot (displacement between the nozzle head and measured surface. The purpose of the analysis was to point out the impact on the metrological characteristics of the air gauge. In particular, attention was paid to the airflow through the measuring slot. Here, the complex phenomena take place, among others the supersonic areas and a “bubble ring,” which cause discontinuity and hysteresis in the static characteristic. On the other hand, the air stream expansion after the restriction (inlet nozzle is observed in the measuring chamber. The point of the above discussion was to work out some recommendation on the nozzles geometry and the localization of the back-pressure measuring point in the chamber.

  10. Numerical simulation on internal and external flow field of a SCAL indirect air cooling tower

    Institute of Scientific and Technical Information of China (English)

    TIAN Songfeng; CHAI Yanqin; XIANG Tongqiong; ZHOU Guangsha

    2014-01-01

    According to the actual size of cooling tube bundle and the arrangement of cooling triangle of a surface condenser aluminum exchangers (SCAL)natural draft cooling tower,the geometric model of heat transfer elements at the tower bottom was established.On the basis of the RNG k-εturbulence model and porous medium model,three-dimensional numerical simulation was carried out for the inner and external flow field of the air cooling tower,to investigate the influence of environmental conditions on the tower's operation performance.The results show that,with an increase in ambient wind speed,the inlet air speed at windward side of the tower increases gradually,while that at crosswind side and lee side decreases and tends to be obvious;the tower ventilation rate and outlet air speed increases at first and then decreases,and their maximum values appear when the wind speed is 2 m/s.

  11. Spatial flow influence factor: A novel concept for indoor air pollutant control

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper puts forward a novel concept, the spatial flow influence factor (SFIF), which provides a new insight into the airflow structure. This concept is very helpful in the control of indoor air pollutants since: (1) for a given indoor airflow and given sources of volatile organic compounds (VOCs), the optimal arrangement of the VOC sources can easily be obtained; (2) for given positions of VOC sources and occupied regions (or target regions), the optimal indoor airflow pattern or organization can be determined; (3) the SFIF for an indoor space can also be regarded as the indoor air safety index of that space. To illustrate this concept, we present several examples of applying a SFIF to indoor air VOC control.

  12. The design of an air-cooled metallic high temperature radial turbine

    Science.gov (United States)

    Snyder, Philip H.; Roelke, Richard J.

    1988-01-01

    Recent trends in small advanced gas turbine engines call for higher turbine inlet temperatures. Advances in radial turbine technology have opened the way for a cooled metallic radial turbine capable of withstanding turbine inlet temperatures of 2500 F while meeting the challenge of high efficiency in this small flow size range. In response to this need, a small air-cooled radial turbine has been designed utilizing internal blade coolant passages. The coolant flow passage design is uniquely tailored to simultaneously meet rotor cooling needs and rotor fabrication constraints. The rotor flow-path design seeks to realize improved aerodynamic blade loading characteristics and high efficiency while satisfying rotor life requirements. An up-scaled version of the final engine rotor is currently under fabrication and, after instrumentation, will be tested in the warm turbine test facility at the NASA Lewis Research Center.

  13. High-density turbidity currents: Are they sandy debris flows?

    Energy Technology Data Exchange (ETDEWEB)

    Shanmugam, G. [Mobil Exploration and Producing Technical Center, Dallas, TX (United States)

    1996-01-01

    Conventionally, turbidity currents are considered as fluidal flows in which sediment is supported by fluid turbulence, whereas debris flows are plastic flows in which sediment is supported by matrix strength, dispersive pressure, and buoyant lift. The concept of high-density turbidity current refers to high-concentration, commonly non-turbulent, flows of fluids in which sediment is supported mainly by matrix strength, dispersive pressure, and buoyant lift. The conventional wisdom that traction carpets with entrained turbulent clouds on top represent high-density turbidity currents is a misnomer because traction carpets are neither fluidal nor turbulent. Debris flows may also have entrained turbulent clouds on top. The traction carpet/debris flow and the overriding turbulent clouds are two separate entities in terms of flow rheology and sediment-support mechanism. In experimental and theoretical studies, which has linked massive sands and floating clasts to high-density turbidity currents, the term high-density turbidity current has actually been used for laminar flows. In alleviating this conceptual problem, sandy debris flow is suggested as a substitute for high-density turbidity current. Sandy debris flows represent a continuous spectrum of processes between cohesive and cohesionless debris flows. Commonly they are rheologically plastic. They may occur with or without entrained turbulent clouds on top. Their sediment-support mechanisms include matrix strength, dispersive pressure, and buoyant lift. They are characterized by laminar flow conditions, a moderate to high grain concentration, and a low to moderate mud content. Although flows evolve and transform during the course of transport in density-stratified flows, the preserved features in a deposit are useful to decipher only the final stages of deposition. At present, there are no established criteria to decipher transport mechanism from the depositional record.

  14. Similarity and cascade flow characteristics of a highly loaded helium compressor

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Bin, E-mail: jiangbin_hrbeu@163.com [College of Power & Energy Engineering of Harbin Engineering University, Harbin 150001 (China); Chen, Zhongliang [College of Power & Energy Engineering of Harbin Engineering University, Harbin 150001 (China); Chen, Hang [AVIG Shenyang Engine Design and Research Institute, Shenyang 110015 (China); Zhang, Hai; Zheng, Qun [College of Power & Energy Engineering of Harbin Engineering University, Harbin 150001 (China)

    2015-05-15

    Highlights: • The deviation of different similarity criteria is analyzed theoretically. • Flow difference between helium and air compressor cascades is analyzed numerically. • The analysis of calculated results validates the theoretical derivation. • Flow characteristics of highly loaded helium compressor blade profile are computed. - Abstract: Helium compressor is a major component of the Power Conversion Unit (PCU) used in a High Temperature Gas Cooled Reactor (HTGR). Because the high cost of closed cycle test and leakage problem of helium gas, air could be used as working fluid instead of helium in compressor performance tests. However, the properties of Helium are largely different from those of air, e.g. the adiabatic exponent of Helium is 1.6, while the adiabatic exponent itself is a criterion of similarity between the two compressors. The characteristics of compressor will be different due to the effect of the adiabatic exponent of working fluid, especially for highly loaded compressor working at higher inlet Mach number. In this paper, a theoretical study on the similarity between air compressor and a highly loaded helium compressor is carried out and the deviation of similarity is analyzed. Numerical simulations are then used to confirm the theoretical analysis. The results indicate that the similarity deviation could not be neglected for highly loaded compressor cascade, which means the experience and experimental results of those conventional air compressor cannot be applied directly to the design of highly loaded helium compressor. The flow characteristics of a highly loaded helium compressor at different Reynolds numbers, attack angles, Mach numbers and cascade geometries are then investigated.

  15. Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator

    Science.gov (United States)

    Muszyński, Tomasz; Kozieł, Sławomir Marcin

    2016-09-01

    Two-dimensional numerical investigations of the fluid flow and heat transfer have been carried out for the laminar flow of the louvered fin-plate heat exchanger, designed to work as an air-source heat pump evaporator. The transferred heat and the pressure drop predicted by simulation have been compared with the corresponding experimental data taken from the literature. Two dimensional analyses of the louvered fins with varying geometry have been conducted. Simulations have been performed for different geometries with varying louver pitch, louver angle and different louver blade number. Constant inlet air temperature and varying velocity ranging from 2 to 8 m/s was assumed in the numerical experiments. The air-side performance is evaluated by calculating the temperature and the pressure drop ratio. Efficiency curves are obtained that can be used to select optimum louver geometry for the selected inlet parameters. A total of 363 different cases of various fin geometry for 7 different air velocities were investigated. The maximum heat transfer improvement interpreted in terms of the maximum efficiency has been obtained for the louver angle of 16 ° and the louver pitch of 1.35 mm. The presented results indicate that varying louver geometry might be a convenient way of enhancing performance of heat exchangers.

  16. Drag reductions and the air-water interface stability of superhydrophobic surfaces in rectangular channel flow

    Science.gov (United States)

    Zhang, Jingxian; Yao, Zhaohui; Hao, Pengfei

    2016-11-01

    Flow in a rectangular channel with superhydrophobic (SH) top and bottom walls was investigated experimentally. Different SH surfaces, including hierarchical structured surfaces and surfaces with different micropost sizes (width and spacing) but the same solid fraction, were fabricated and measured. Pressure loss and flow rate in the channel with SH top and bottom walls were measured, with Reynolds number changing from 700 to 4700, and the corresponding friction factor for the SH surface was calculated. The statuses of the air plastron on different SH surfaces were observed during the experiment. In our experiment, compared with the experiment for the smooth surface, drag reductions were observed for all SH surfaces, with the largest drag reduction of 42.2%. It was found that the hierarchy of the microstructure can increase the drag reduction by decreasing the solid fraction and enhancing the stability of the air-water interface. With a fixed solid fraction, the drag reduction decreases as the post size (width and spacing) increases, due to the increasing curvature and instability effects of the air-water interface. A correlation parameter between the contact angle hysteresis, the air-water interface stability, and the drag reduction of the SH surfaces was found.

  17. [Estimation of average traffic emission factor based on synchronized incremental traffic flow and air pollutant concentration].

    Science.gov (United States)

    Li, Run-Kui; Zhao, Tong; Li, Zhi-Peng; Ding, Wen-Jun; Cui, Xiao-Yong; Xu, Qun; Song, Xian-Feng

    2014-04-01

    On-road vehicle emissions have become the main source of urban air pollution and attracted broad attentions. Vehicle emission factor is a basic parameter to reflect the status of vehicle emissions, but the measured emission factor is difficult to obtain, and the simulated emission factor is not localized in China. Based on the synchronized increments of traffic flow and concentration of air pollutants in the morning rush hour period, while meteorological condition and background air pollution concentration retain relatively stable, the relationship between the increase of traffic and the increase of air pollution concentration close to a road is established. Infinite line source Gaussian dispersion model was transformed for the inversion of average vehicle emission factors. A case study was conducted on a main road in Beijing. Traffic flow, meteorological data and carbon monoxide (CO) concentration were collected to estimate average vehicle emission factors of CO. The results were compared with simulated emission factors of COPERT4 model. Results showed that the average emission factors estimated by the proposed approach and COPERT4 in August were 2.0 g x km(-1) and 1.2 g x km(-1), respectively, and in December were 5.5 g x km(-1) and 5.2 g x km(-1), respectively. The emission factors from the proposed approach and COPERT4 showed close values and similar seasonal trends. The proposed method for average emission factor estimation eliminates the disturbance of background concentrations and potentially provides real-time access to vehicle fleet emission factors.

  18. Numerical Study of Water Production from Compressible Moist-Air Flow

    Directory of Open Access Journals (Sweden)

    sabah hamidi

    2016-01-01

    Full Text Available In this research a numerical study of water production from compressible moist-air flow by condensing of the vapor component of the atmospheric air through a converging-diverging nozzle is performed. The atmospheric air can be sucked by a vacuum compressor. The geographical conditions represent a hot and humid region, for example Bandar Abbas, Iran, with coordinates, 270 11 ’ N and 560 16’ E and summer climate conditions of about 40℃and relative humidity above 80%. Parametric studies are performed for the atmospheric-air temperature between, 40℃ to 50℃, and relative humidity between49.6% to 100.%. For these ranges of operating conditions and a nozzle with the area ratio of 1.17, the liquid mass flow rates falls in the range 0.272 to 0.376 kg/s. The results show that, the energy consumed by the compressor for production 1 kg of water will be 1.279 kWh. The price of 1 kWh is 372 Rials, therefore the price for the production of 1 kg liquid water will be 475.8 Rials, therefore, the scheme is economically suitable.

  19. Practical Strategies for Stable Operation of HFF-QCM in Continuous Air Flow

    Directory of Open Access Journals (Sweden)

    Siegfried R. Waldvogel

    2013-09-01

    Full Text Available Currently there are a few fields of application using quartz crystal microbalances (QCM. Because of environmental conditions and insufficient resolution of the microbalance, chemical sensing of volatile organic compounds in an open system was as yet not possible. In this study we present strategies on how to use 195 MHz fundamental quartz resonators for a mobile sensor platform to detect airborne analytes. Commonly the use of devices with a resonant frequency of about 10 MHz is standard. By increasing the frequency to 195 MHz the frequency shift increases by a factor of almost 400. Unfortunately, such kinds of quartz crystals tend to exhibit some challenges to obtain a reasonable signal-to-noise ratio. It was possible to reduce the noise in frequency in a continuous air flow of 7.5 m/s to 0.4 Hz [i.e., σ(τ = 2 × 10−9] by elucidating the major source of noise. The air flow in the vicinity of the quartz was analyzed to reduce turbulences. Furthermore, we found a dependency between the acceleration sensitivity and mechanical stress induced by an internal thermal gradient. By reducing this gradient, we achieved reduction of the sensitivity to acceleration by more than one decade. Hence, the resulting sensor is more robust to environmental conditions such as temperature, acceleration and air flow.

  20. Elasto-Aerodynamics-Driven Triboelectric Nanogenerator for Scavenging Air-Flow Energy.

    Science.gov (United States)

    Wang, Shuhua; Mu, Xiaojing; Wang, Xue; Gu, Alex Yuandong; Wang, Zhong Lin; Yang, Ya

    2015-10-27

    Efficient scavenging the kinetic energy from air-flow represents a promising approach for obtaining clean, sustainable electricity. Here, we report an elasto-aerodynamics-driven triboelectric nanogenerator (TENG) based on contact electrification. The reported TENG consists of a Kapton film with two Cu electrodes at each side, fixed on two ends in an acrylic fluid channel. The relationship between the TENG output power density and its fluid channel dimensions is systematically studied. TENG with a fluid channel size of 125 × 10 × 1.6 mm(3) delivers the maximum output power density of about 9 kW/m(3) under a loading resistance of 2.3 MΩ. Aero-elastic flutter effect explains the air-flow induced vibration of Kapton film well. The output power scales nearly linearly with parallel wiring of multiple TENGs. Connecting 10 TENGs in parallel gives an output power of 25 mW, which allows direct powering of a globe light. The TENG is also utilized to scavenge human breath induced air-flow energy to sustainably power a human body temperature sensor.

  1. Hybridized electromagnetic-triboelectric nanogenerator for scavenging air-flow energy to sustainably power temperature sensors.

    Science.gov (United States)

    Wang, Xue; Wang, Shuhua; Yang, Ya; Wang, Zhong Lin

    2015-04-28

    We report a hybridized nanogenerator with dimensions of 6.7 cm × 4.5 cm × 2 cm and a weight of 42.3 g that consists of two triboelectric nanogenerators (TENGs) and two electromagnetic generators (EMGs) for scavenging air-flow energy. Under an air-flow speed of about 18 m/s, the hybridized nanogenerator can deliver largest output powers of 3.5 mW for one TENG (in correspondence of power per unit mass/volume: 8.8 mW/g and 14.6 kW/m(3)) at a loading resistance of 3 MΩ and 1.8 mW for one EMG (in correspondence of power per unit mass/volume: 0.3 mW/g and 0.4 kW/m(3)) at a loading resistance of 2 kΩ, respectively. The hybridized nanogenerator can be utilized to charge a capacitor of 3300 μF to sustainably power four temperature sensors for realizing self-powered temperature sensor networks. Moreover, a wireless temperature sensor driven by a hybridized nanogenerator charged Li-ion battery can work well to send the temperature data to a receiver/computer at a distance of 1.5 m. This work takes a significant step toward air-flow energy harvesting and its potential applications in self-powered wireless sensor networks.

  2. Extinction characterization of soot produced by laser ablating carbon fiber composite materials in air flow

    Science.gov (United States)

    Liu, Weiping; Ma, Zhiliang; Zhang, Zhenrong; Zhou, Menglian; Wei, Chenghua

    2015-05-01

    In order to research the dynamic process of energy coupling between an incident laser and a carbon fiber/epoxy resin composite material, an extinction characterization analysis of soot, which is produced by laser ablating and located in an air flow that is tangential to the surface of the composite material, is carried out. By the theory analyses, a relationship of mass extinction coefficient and extinction cross section of the soot is derived. It is obtained that the mass extinction coefficients of soot aggregates are the same as those of the primary particles when they contain only a few primary particles. This conclusion is significant when the soot is located in an air flow field, where the generations of the big soot aggregates are suppressed. A verification experiment is designed. The experiment employs Laser Induced Incandescence technology and laser extinction method for the soot synchronization diagnosis. It can derive a temporal curve of the mass extinction coefficient from the soot concentration and laser transmittance. The experiment results show that the mass extinction coefficient becomes smaller when the air flow velocity is higher. The reason is due to the decrease of the scatter effects of the soot particles. The experiment results agree with the theory analysis conclusion.

  3. Practical strategies for stable operation of HFF-QCM in continuous air flow.

    Science.gov (United States)

    Wessels, Alexander; Klöckner, Bernhard; Siering, Carsten; Waldvogel, Siegfried R

    2013-09-09

    Currently there are a few fields of application using quartz crystal microbalances (QCM). Because of environmental conditions and insufficient resolution of the microbalance, chemical sensing of volatile organic compounds in an open system was as yet not possible. In this study we present strategies on how to use 195 MHz fundamental quartz resonators for a mobile sensor platform to detect airborne analytes. Commonly the use of devices with a resonant frequency of about 10 MHz is standard. By increasing the frequency to 195 MHz the frequency shift increases by a factor of almost 400. Unfortunately, such kinds of quartz crystals tend to exhibit some challenges to obtain a reasonable signal-to-noise ratio. It was possible to reduce the noise in frequency in a continuous air flow of 7.5 m/s to 0.4 Hz [i.e., σ(τ) = 2 × 10-9] by elucidating the major source of noise. The air flow in the vicinity of the quartz was analyzed to reduce turbulences. Furthermore, we found a dependency between the acceleration sensitivity and mechanical stress induced by an internal thermal gradient. By reducing this gradient, we achieved reduction of the sensitivity to acceleration by more than one decade. Hence, the resulting sensor is more robust to environmental conditions such as temperature, acceleration and air flow.

  4. High Resolution Projection of Future Air Quality in South Asia

    Science.gov (United States)

    Kumar, R.; Barth, M. C.; Pfister, G.; Lamarque, J. F.; Walters, S.; Naja, M. K.; Ghude, S. D.

    2015-12-01

    About one seventh of the world's population living in South Asia faces the risk of severe air pollution due to high anthropogenic emissions of air pollutants. Recent studies have shown that exposure to present day air pollution in South Asia is sufficient enough to reduce the lifespan of about 660 million people by about 3 years, destroy food that can feed about 94 million poor people and cause economic loss of several billion dollars. This problem may worsen in the future as anthropogenic emissions are expected to increase due to rapid economic growth in South Asia, and climate change is expected to lead to atmospheric conditions conducive for the production and accumulation of air pollutants. In order to predict how air quality will change in South Asia in future (2050), we are conducting high resolution air quality simulations for the present day (2005-2014) and future (2046-2055) time periods using the Nested Regional Climate Model coupled with Chemistry (NRCM-Chem). The model domain covers entire South Asia at a horizontal grid spacing of 60 km with a nested domain over the densely populated and polluted Indo-Gangetic Plain region at a horizontal grid spacing of 12 km. The model results are being evaluated with available in situ and satellite based observations and the evaluation results show that NRCM-Chem model is able to capture several important features of the observed spatial and temporal distribution of key meteorological parameters and air pollutants. Initial model results show that annual average surface ozone and PM2.5 concentrations may increase by up to 15 ppbv and 25 μg m-3, respectively with highest increase in the Indo-Gangetic Plain.

  5. Heat-transfer coefficients for air flowing in round tubes, in rectangular ducts, and around finned cylinders

    Science.gov (United States)

    Drexel, Rober E; Mcadams, William H

    1945-01-01

    Report reviews published data and presents some new data on heat transfer to air flowing in round tubes, in rectangular ducts, and around finned cylinders. The available data for heat transfer to air in straight ducts of rectangular and circular cross section have been correlated in plots of Stanton number versus Reynolds number to provide a background for the study of the data for finned cylinders. Equations are recommended for both the streamlined and turbulent regions, and data are presented for the transition region between turbulent and laminar flow. Use of hexagonal ends on round tubes causes the characteristics of laminar flow to extend to high Reynolds numbers. Average coefficients for the entire finned cylinder have been calculated from the average temperature at the base of the fins and an equation which was derived to allow for the effectiveness of the fins. The available results for each finned cylinder are correlated herein in terms of graphs of Stanton number versus Reynolds number. In general, for a given Reynolds number, the Stanton number increases with increases in both spacing and width of the fins, and is apparently independent of cylinder diameter and temperature difference. For a given coefficient of heat transfer improved baffles and rough or wavy surfaces give a substantial reduction in pumping power per unit of heat transfer surface and a somewhat smaller decrease in pressure drop. (author)

  6. Novel solar air Heater for high temperatures; Novedoso Calentador solar de aire para altas temperaturas

    Energy Technology Data Exchange (ETDEWEB)

    Rincon, E. A.; Duran, M. D.; Lentz, A. E.

    2008-07-01

    A novel solar air heater that allows to reach temperatures of the order of 100 degree centigrade with thermal efficiencies superior to 50% due to a solar concentrator and the reduction of thermal losses from the air when circulating between the absorber and mirrors of section of circular arc, well isolated of the outside surrounding. The receiver consists of a concentrator with wedges of plastic transparency that make the function of lenses. The light refracted by the wedges enters to a series of concentrators PC type truncated optimally so that the space among them allows the positioning of the absorber, who are covered metallic segments with selective film. Its excellent performance makes ideals applications as Sauna bath, the drying at high temperature, and systems for conditioning of air. (Author)

  7. An improved continuous flow analysis system for high-resolution field measurements on ice cores.

    Science.gov (United States)

    Kaufmann, Patrik R; Federer, Urs; Hutterli, Manuel A; Bigler, Matthias; Schüpbach, Simon; Ruth, Urs; Schmitt, Jochen; Stocker, Thomas F

    2008-11-01

    Continuous flow analysis (CFA) is a well-established method to obtain information about impurity contents in ice cores as indicators of past changes in the climate system. A section of an ice core is continuously melted on a melter head supplying a sample water flow which is analyzed online. This provides high depth and time resolution of the ice core records and very efficient sample decontamination as only the inner part of the ice sample is analyzed. Here we present an improved CFA system which has been totally redesigned in view of a significantly enhanced overall efficiency and flexibility, signal quality, compactness, and ease of use. These are critical requirements especially for operations of CFA during field campaigns, e.g., in Antarctica or Greenland. Furthermore, a novel deviceto measure the total air content in the ice was developed. Subsequently, the air bubbles are now extracted continuously from the sample water flow for subsequent gas measurements.

  8. Turbulence, aeration and bubble features of air-water flows over macro- and intermediate roughness

    Directory of Open Access Journals (Sweden)

    Stefano PAGLIARA

    2011-06-01

    Full Text Available Free surface flows in macro- and intermediate roughness conditions have a high aeration potential in which the flow characteristics vary with slopes and discharges. The underlying phenomenon of two phase flow characteristics in the macro and intermediate roughness conditions were analyzed in a setup assembled at the PITLAB center of the University of Pisa, Italy. Crushed angular rocks and hemispherical boulders were used to intensify the roughness nature of the bed. Flow discharges per unit width ranging between 0.03 m2/s and 0.09 m2/s and slopes between 0.26 and 0.46 were tested over different arrangements of rough bed. Analyses were mainly concentrated in the inner flow region which constitutes both bubbly and intermediate flow region. The findings revealed that two phase flow properties over rough bed were very much affected by the different rough bed arrangement. Turbulence features of two phase flows over rough beds were compared with that of the stepped chute data under similar flow conditions. Overall the results highlighted the flow features in the inner layers of the two phase flow.

  9. Design and parametric optimization of thermal management of lithium-ion battery module with reciprocating air-flow

    Institute of Scientific and Technical Information of China (English)

    刘燕平; 欧阳陈志; 江清柏; 梁波

    2015-01-01

    Single cell temperature difference of lithium-ion battery (LIB) module will significantly affect the safety and cycle life of the battery. The reciprocating air-flow module created by a periodic reversal of the air flow was investigated in an effort to mitigate the inherent temperature gradient problem of the conventional battery system with a unidirectional coolant flow with computational fluid dynamics (CFD). Orthogonal experiment and optimization design method based on computational fluid dynamics virtual experiments were developed. A set of optimized design factors for the cooling of reciprocating air flow of LIB thermal management was determined. The simulation experiments show that the reciprocating flow can achieve good heat dissipation, reduce the temperature difference, improve the temperature homogeneity and effectively lower the maximal temperature of the modular battery. The reciprocating flow improves the safety, long-term performance and life span of LIB.

  10. Horizontal high-pressure air injection well construction and operation

    Energy Technology Data Exchange (ETDEWEB)

    Hume, J. [Continental Resources Inc., ND (United States)

    2005-07-01

    This paper discussed the design and operational challenges of a horizontal high-pressure air injection well currently in use at the Cedar Hill Red River B field in North Dakota. The field was developed in 1994, using horizontal wells oriented from the northeast to the southwest corners of each section on 640 acre spacing. In March of 2001, the field was unitized resulting in a horizontal waterflood project and a 320 acre horizontal high pressure air injection project. Extreme temperatures and pressures occurring in the reservoir from the combustion processes associated with high pressure air injection have resulted in several challenges. Reservoir and fluid properties of the field were presented, as well as a type log. Details of the Buffalo and Cedar Hills field were also provided, with a comparison of horizontal and vertical patterns. A light oil displacement process was reviewed, with details of tubing leak corrosion, packer seal and detonation failures. Burn front exposure to casing was discussed, and a wellbore diagram was provided. Various horizontal conversions were discussed. A description of the Cedar Hills Compressor Station and compression trains was provided. It was concluded that knowledge gained from 25 years of vertical high pressure air injection experience has been successfully incorporated to create a safe and durable design. 1 tab., 16 figs.

  11. Pneumomediastinum following high pressure air injection to the hand.

    LENUS (Irish Health Repository)

    Kennedy, J

    2012-02-01

    We present the case of a patient who developed pneumomediastinum after high pressure air injection to the hand. To our knowledge this is the first reported case of pneumomediastinum where the gas injection site was the thenar eminence. Fortunately the patient recovered with conservative management.

  12. Pneumomediastinum following high pressure air injection to the hand.

    LENUS (Irish Health Repository)

    Kennedy, J

    2010-04-01

    We present the case of a patient who developed pneumomediastinum after high pressure air injection to the hand. To our knowledge this is the first reported case of pneumomediastinum where the gas injection site was the thenar eminence. Fortunately the patient recovered with conservative management.

  13. Air temperature variability in a high-elevation Himalayan catchment

    NARCIS (Netherlands)

    Heynen, Martin; Miles, Evan; Ragettli, Silvan; Buri, Pascal; Immerzeel, Walter W.; Pellicciotti, Francesca

    2016-01-01

    Air temperature is a key control of processes affecting snow and glaciers in high-elevation catchments, including melt, snowfall and sublimation. It is therefore a key input variable to models of land-surface-atmosphere interaction. Despite this importance, its spatial variability is poorly

  14. Influence of air flow rate and backwashing on the hydraulic behaviour of a submerged filter.

    Science.gov (United States)

    Cobos-Becerra, Yazmin Lucero; González-Martínez, Simón

    2013-01-01

    The aim of this study was to evaluate backwashing effects on the apparent porosity of the filter media and on the hydraulic behaviour of a pilot scale submerged filter, prior to biofilm colonization, under different hydraulic retention times, and different air flow rates. Tracer curves were analysed with two mathematical models for ideal and non-ideal flow (axial dispersion and Wolf and Resnick models). The filter media was lava stones sieved to 4.5 mm. Backwashing causes attrition of media particles, decreasing the void volume of the filter media and, consequently, the tracer flow is more uniform. The eroded media presented lower dead volumes (79% for the filter with aeration and 8% for the filter without aeration) compared with the new media (83% for the filter with aeration and 22% for the filter without aeration). The flow patterns of eroded and new media were different because the more regular shape of the particles decreases the void volume of the filter media. The dead volume is attributed, in the case of the filter with aeration, to the turbulence caused by the air bubbles that generate preferential channelling of the bulk liquid along the filter media, creating large zones of stagnant liquid and, for the filter without aeration, to the channels formed due to the irregular shaped media.

  15. Analysis of the air flow generated by an air-assisted sprayer equipped with two axial fans using a 3D sonic anemometer.

    Science.gov (United States)

    García-Ramos, F Javier; Vidal, Mariano; Boné, Antonio; Malón, Hugo; Aguirre, Javier

    2012-01-01

    The flow of air generated by a new design of air assisted sprayer equipped with two axial fans of reversed rotation was analyzed. For this goal, a 3D sonic anemometer has been used (accuracy: 1.5%; measurement range: 0 to 45 m/s). The study was divided into a static test and a dynamic test. During the static test, the air velocity in the working vicinity of the sprayer was measured considering the following machine configurations: (1) one activated fan regulated at three air flows (machine working as a traditional sprayer); (2) two activated fans regulated at three air flows for each fan. In the static test 72 measurement points were considered. The location of the measurement points was as follow: left and right sides of the sprayer; three sections of measurement (A, B and C); three measurement distances from the shaft of the machine (1.5 m, 2.5 m and 3.5 m); and four measurement heights (1 m, 2 m, 3 m and 4 m). The static test results have shown significant differences in the module and the vertical angle of the air velocity vector in function of the regulations of the sprayer. In the dynamic test, the air velocity was measured at 2.5 m from the axis of the sprayer considering four measurement heights (1 m, 2 m, 3 m and 4 m). In this test, the sprayer regulations were: one or two activated fans; one air flow for each fan; forward speed of 2.8 km/h. The use of one fan (back) or two fans (back and front) produced significant differences on the duration of the presence of wind in the measurement point and on the direction of the air velocity vector. The module of the air velocity vector was not affected by the number of activated fans.

  16. Analysis of the Air Flow Generated by an Air-Assisted Sprayer Equipped with Two Axial Fans Using a 3D Sonic Anemometer

    Directory of Open Access Journals (Sweden)

    Javier Aguirre

    2012-06-01

    Full Text Available The flow of air generated by a new design of air assisted sprayer equipped with two axial fans of reversed rotation was analyzed. For this goal, a 3D sonic anemometer has been used (accuracy: 1.5%; measurement range: 0 to 45 m/s. The study was divided into a static test and a dynamic test. During the static test, the air velocity in the working vicinity of the sprayer was measured considering the following machine configurations: (1 one activated fan regulated at three air flows (machine working as a traditional sprayer; (2 two activated fans regulated at three air flows for each fan. In the static test 72 measurement points were considered. The location of the measurement points was as follow: left and right sides of the sprayer; three sections of measurement (A, B and C; three measurement distances from the shaft of the machine (1.5 m, 2.5 m and 3.5 m; and four measurement heights (1 m, 2 m, 3 m and 4 m. The static test results have shown significant differences in the module and the vertical angle of the air velocity vector in function of the regulations of the sprayer. In the dynamic test, the air velocity was measured at 2.5 m from the axis of the sprayer considering four measurement heights (1 m, 2 m, 3 m and 4 m. In this test, the sprayer regulations were: one or two activated fans; one air flow for each fan; forward speed of 2.8 km/h. The use of one fan (back or two fans (back and front produced significant differences on the duration of the presence of wind in the measurement point and on the direction of the air velocity vector. The module of the air velocity vector was not affected by the number of activated fans.

  17. Flux Vector Splitting Schemes for Water Hammer Flows in Pumping Supply Systems with Air Vessels

    Institute of Scientific and Technical Information of China (English)

    Qiang Sun; Yuebin Wu; Ying Xu; Tae Uk Jang

    2015-01-01

    To solve water hammer problems in pipeline systems, many numerical simulation approaches have been developed. This paper improves a flux vector splitting ( FVS) scheme whose grid is the same as the fixed⁃grid MOC scheme. The proposed FVS scheme is used to analyze water hammer problems caused by a pump abrupt shutdown in a pumping system with an air vessel. This paper also proposes a pump⁃valve⁃vessel model combining a pump⁃valve model with an air vessel model. The results show that the data obtained by the FVS scheme are similar to the ones obtained by the fixed⁃grid method of characteristics ( MOC ) . And the results using the pump⁃valve⁃vessel model are almost the same as the ones using both the pump⁃valve model and the air vessel model. Therefore, it is effective that the proposed FVS scheme is used to solve water hammer problems and the pump⁃valve⁃vessel model replaces both the pump⁃valve model and the air vessel model to simulate water hammer flows in the pumping system with the air vessel.

  18. Influence of air flow, temperature and agitation speed in the batch acetification process to obtain orange vinegar (Citrus sinensis var.W. Navel

    Directory of Open Access Journals (Sweden)

    María Ferreyra

    2012-03-01

    Full Text Available This paper describes the influence of process variables to produce orange vinegar. Orange juice was fermented with Saccharomyces cerevisiae until reach 14% v/v. The biooxidation was carried out with Acetobacter sp., in submerge culture using a laboratory scale fermentor. In order to avoid the inhibitory effect of ethanol on acetic acid bacteria, the orange wine was diluted to 6% v/v with a mineral solution. It was performed a factorial design 2k to study the influence of variables. It was studied air flow rate/agitation at levels of 0.3-0.6 vvm and 200-400 rpm and the effect of air flow rate/temperature at 0.4-0.6 vvm and 25- 30°C, respectively. Duplicate treatments were carried out and the results were evaluated in terms of productivity and fermentation yield. Statistical design (p-value<0.05 was analyzed using Statgraphics Centurion XV Corporate software. Treatments performed at 200 rpm and different air flow levels, did not show significant differences on acetification rate. At higher agitation speed and air flow rates, the productivity was high. The best yields were obtained at lower air flows levels and higher agitation speed. Temperature did not present statistically differences on studied variables. The best yield was obtained at 400 rpm and 0.3 vvm at 25°C. It can be concluded that agitation speed plays an important role for a better acetification rate however higher air flow rates causes less yields.

  19. STUDY OF FLOW IN AIR-INTAKE SYSTEM FOR A SINGLE-CYLINDER GO-KART ENGINE

    Directory of Open Access Journals (Sweden)

    S. A. Sulaiman

    2010-06-01

    Full Text Available Intake-air manifolds have a major effect on a vehicle’s engine performance and emission of noise and pollutants. Differences in engine outputs and applications require different designs of intake-air manifolds in order to achieve the best volumetric efficiency and thus the best engine performance. In the present work, the flow characteristics of air flowing in various designs of air-intake manifold of a 200-cc four-stroke Go-Kart engine are studied. The study is done by three dimensional simulations of the flow of air within six designs of air-intake manifold into the combustion chamber by using commercial CFD software, Fluent version 6.2. The simulation results are validated by an experimental study performed using a flow bench. The study reveals that the variations in the geometry of the air-intake system can result in a difference of up to 20% in the mass flow rate of air entering the combustion chamber.

  20. Onsite survey on the mechanism of passive aeration and air flow path in a semi-aerobic landfill.

    Science.gov (United States)

    Matsuto, Toshihiko; Zhang, Xin; Matsuo, Takayuki; Yamada, Shuhei

    2015-02-01

    The semi-aerobic landfill is a widely accepted landfill concept in Japan because it promotes stabilization of leachates and waste via passive aeration without using any type of mechanical equipment. Ambient air is thought to be supplied to the landfill through a perforated pipe network made of leachate collection pipe laid along the bottom and a vertically erected gas vent. However, its underlying air flow path and driving forces are unclear because empirical data from real-world landfills is inadequate. The objective of this study is to establish scientific evidence about the aeration mechanisms and air flow path by an on-site survey of a full-scale, semi-aerobic landfill. First, all passive vents located in the landfill were monitored with respect to temperature level and gas velocity in different seasons. We found a linear correlation between the outflow rate and gas temperature, suggesting that air flow is driven by a buoyancy force caused by the temperature difference between waste in the landfill and the ambient temperature. Some vents located near the landfill bottom acted as air inflow vents. Second, we conducted a tracer test to determine the air flow path between two vents, by injecting tracer gas from an air sucking vent. The resulting slowly increasing gas concentration at the neighboring vent suggested that fresh air flow passes through the waste layer toward the gas vents from leachate collection pipes, as well as directly flowing through the pipe network. Third, we monitored the temperature of gas flowing out of a vent at night. Since the temperature drop of the gas was much smaller than that of the environment, the air collected at the gas vents was estimated to flow mostly through the waste layer, i.e., the semi-aerobic landfill has considerable aeration ability under the appropriate conditions.

  1. Ground-to-air flow visualization using Solar Calcium-K line Background-Oriented Schlieren

    Science.gov (United States)

    Hill, Michael A.; Haering, Edward A.

    2017-01-01

    The Calcium-K Eclipse Background-Oriented Schlieren experiment was performed as a proof of concept test to evaluate the effectiveness of using the solar disk as a background to perform the Background-Oriented Schlieren (BOS) method of flow visualization. A ground-based imaging system was equipped with a Calcium-K line optical etalon filter to enable the use of the chromosphere of the sun as the irregular background to be used for BOS. A US Air Force T-38 aircraft performed three supersonic runs which eclipsed the sun as viewed from the imaging system. The images were successfully post-processed using optical flow methods to qualitatively reveal the density gradients in the flow around the aircraft.

  2. Experimental Investigation of Flow Resistance in a Coal Mine Ventilation Air Methane Preheated Catalytic Oxidation Reactor

    Directory of Open Access Journals (Sweden)

    Bin Zheng

    2015-01-01

    Full Text Available This paper reports the results of experimental investigation of flow resistance in a coal mine ventilation air methane preheated catalytic oxidation reactor. The experimental system was installed at the Energy Research Institute of Shandong University of Technology. The system has been used to investigate the effects of flow rate (200 Nm3/h to 1000 Nm3/h and catalytic oxidation bed average temperature (20°C to 560°C within the preheated catalytic oxidation reactor. The pressure drop and resistance proportion of catalytic oxidation bed, the heat exchanger preheating section, and the heat exchanger flue gas section were measured. In addition, based on a large number of experimental data, the empirical equations of flow resistance are obtained by the least square method. It can also be used in deriving much needed data for preheated catalytic oxidation designs when employed in industry.

  3. Interfacial structures of confined air-water two-phase bubbly flow

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S.; Ishii, M.; Wu, Q.; McCreary, D.; Beus, S.G.

    2000-08-01

    The interfacial structure of the two-phase flows is of great importance in view of theoretical modeling and practical applications. In the present study, the focus is made on obtaining detailed local two-phase parameters in the air-water bubbly flow in a rectangular vertical duct using the double-sensor conductivity probe. The characteristic wall-peak is observed in the profiles of the interracial area concentration and the void fraction. The development of the interfacial area concentration along the axial direction of the flow is studied in view of the interfacial area transport and bubble interactions. The experimental data is compared with the drift flux model with C{sub 0} = 1.35.

  4. Flow patterns of natural convection in an air-filled vertical cavity

    Science.gov (United States)

    Wakitani, Shunichi

    1998-08-01

    Flow patterns of two-dimensional natural convection in a vertical air-filled tall cavity with differentially heated sidewalls are investigated. Numerical simulations based on a finite difference method are carried out for a wide range of Rayleigh numbers and aspect ratios from the onset of the steady multicellular flow, through the reverse transition to the unicellular pattern, to the unsteady multicellular flow. For aspect ratios (height/width) from 10 to 24, the various cellular structures characterized by the number of secondary cells are clarified from the simulations by means of gradually increasing Rayleigh number to 106. Unsteady multicellular solutions are found in some region of Rayleigh numbers less than those at which the reverse transition has occurred.

  5. Super energy flows in a waveguide filled with air and left-handed materials

    Institute of Scientific and Technical Information of China (English)

    Yu Guan-Xia; Cui Tie-Jun

    2008-01-01

    The phenomena of super energy flows are studied theoretically and numerically in a parallel-plate waveguide which is filled with two layered equally-thick different media,i.e.air and specific left-handed materials (LHM) with 6r1 =-1/(1+5) + iγ and μr1=-(1 +δ) + iγ.In this special waveguide,two-directional super-energy flows are excited by a three-dimensional horizontal electric dipole at the same time,which has transmission patterns different from those of two-dimensional source and three-dimensional vertical electric dipole.We also show that the retardation and loss in LHM are sensitive to the amplitude of super power densities,and the dimensions of waveguide determine the propagating modes,which makes super energy flows more practical.

  6. Large-eddy structures of turbulent swirling flows and methane-air swirling diffusion combustion

    Institute of Scientific and Technical Information of China (English)

    Liyuan Hu; Lixing Zhou; Jian Zhang; Keren Wang

    2005-01-01

    Turbulent swirling flows and methane-air swirling diffusion combustion are studied by large-eddy simulation (LES) using a Smagorinsky-Lilly subgrid scale turbulence model and a second-order moment (SOM) SGS combustion model, and also by RANS modeling using the Reynolds Stress equation model with the IPCM+wall and IPCM pressure-strain models and SOM combustion model. The LES statistical results for swirling flows give good agreement with the experimental results, indicating that the adopted subgrid-scale turbulence model is suitable for swirling flows.The LES instantaneous results show the complex vortex shedding pattern in swirling flows. The initially formed large vortex structures soon break up in swirling flows. The LES statistical results of combustion modeling are near the experimental results and are as good as the RANS-SOM modeling results. The LES results show that the size and range of large vortex structures in swirling combustion are different from those of isothermal swirling flows, and the chemical reaction is intensified by the large-eddy vortex structures.

  7. Air quality high resolution simulations of Italian urban areas with WRF-CHIMERE

    Science.gov (United States)

    Falasca, Serena; Curci, Gabriele

    2017-04-01

    The new European Directive on ambient air quality and cleaner air for Europe (2008/50/EC) encourages the use of modeling techniques to support the observations in the assessment and forecasting of air quality. The modelling system based on the combination of the WRF meteorological model and the CHIMERE chemistry-transport model is used to perform simulations at high resolution over the main Italian cities (e.g. Milan, Rome). Three domains covering Europe, Italy and the urban areas are nested with a decreasing grid size up to 1 km. Numerical results are produced for a winter month and a summer month of the year 2010 and are validated using ground-based observations (e.g. from the European air quality database AirBase). A sensitivity study is performed using different physics options, domain resolution and grid ratio; different urban parameterization schemes are tested using also characteristic morphology parameters for the cities considered. A spatial reallocation of anthropogenic emissions derived from international (e.g. EMEP, TNO, HTAP) and national (e.g. CTN-ACE) emissions inventories and based on the land cover datasets (Global Land Cover Facility and GlobCover) and the OpenStreetMap tool is also included. Preliminary results indicate that the introduction of the spatial redistribution at high-resolution allows a more realistic reproduction of the distribution of the emission flows and thus the concentrations of the pollutants, with significant advantages especially for the urban environments.

  8. Aerodynamic Study on Supersonic Flows in High-Velocity Oxy-Fuel Thermal Spray Process

    Institute of Scientific and Technical Information of China (English)

    Hiroshi KATANODA; Takeshi MATSUOKA; Seiji KURODA; Jin KAWAKITA; Hirotaka FUKANUMA; Kazuyasu MATSUO

    2005-01-01

    @@ To clarify the characteristics of gas flow in high velocity oxy-fuel (HVOF) thermal spray gun, aerodynamic research is performed using a special gun. The gun has rectangular cross-sectional area and sidewalls of optical glass to visualize the internal flow. The gun consists of a supersonic nozzle with the design Mach number of 2.0 followed by a straight passage called barrel. Compressed dry air up to 0.78 MPa is used as a process gas instead of combustion gas which is used in a commercial HVOF gun. The high-speed gas flows with shock waves in the gun and jets are visualized by schlieren technique. Complicated internal and external flow-fields containing various types of shock wave as well as expansion wave are visualized.

  9. Computational Fluid Dynamics Analyses on Very High Temperature Reactor Air Ingress

    Energy Technology Data Exchange (ETDEWEB)

    Chang H Oh; Eung S. Kim; Richard Schultz; David Petti; Hyung S. Kang

    2009-07-01

    A preliminary computational fluid dynamics (CFD) analysis was performed to understand density-gradient-induced stratified flow in a Very High Temperature Reactor (VHTR) air-ingress accident. Various parameters were taken into consideration, including turbulence model, core temperature, initial air mole-fraction, and flow resistance in the core. The gas turbine modular helium reactor (GT-MHR) 600 MWt was selected as the reference reactor and it was simplified to be 2-D geometry in modeling. The core and the lower plenum were assumed to be porous bodies. Following the preliminary CFD results, the analysis of the air-ingress accident has been performed by two different codes: GAMMA code (system analysis code, Oh et al. 2006) and FLUENT CFD code (Fluent 2007). Eventually, the analysis results showed that the actual onset time of natural convection (~160 sec) would be significantly earlier than the previous predictions (~150 hours) calculated based on the molecular diffusion air-ingress mechanism. This leads to the conclusion that the consequences of this accident will be much more serious than previously expected.

  10. Associations between air pollution and peak expiratory flow among patients with persistent asthma.

    Science.gov (United States)

    Qian, Zhengmin; Lin, Hung-Mo; Chinchilli, Vernon M; Lehman, Erik B; Stewart, Walter F; Shah, Nirav; Duan, Yinkang; Craig, Timothy J; Wilson, William E; Liao, Duanping; Lazarus, Stephen C; Bascom, Rebecca

    2009-01-01

    Responses of patients with persistent asthma to ambient air pollution may be different from those of general populations. For example, asthma medications may modify the effects of ambient air pollutants on peak expiratory flow (PEF). Few studies examined the association between air pollution and PEF in patients with persistent asthma on well-defined medication regimens using asthma clinical trial data. Airway obstruction effects of ambient air pollutants, using 14,919 person-days of daily self-measured peak expiratory flow (PEF), were assessed from 154 patients with persistent asthma during the 16 wk of active treatment in the Salmeterol Off Corticosteroids Study trial. The three therapies were an inhaled corticosteroid, an inhaled long-acting beta-agonist, and placebo. The participants were nonsmokers aged 12 through 63 yr, recruited from 6 university-based ambulatory care centers from February 1997 to January 1999. Air pollution data were derived from the U.S. Environmental Protection Agency Aerometric Information Retrieval System. An increase of 10 ppb of ambient daily mean concentrations of NO2 was associated with a decrease in PEF of 1.53 L/min (95% confidence interval [CI] -2.93 to -0.14) in models adjusted for age, gender, race/ethnicity, asthma clinical center, season, week, daily average temperature, and daily average relative humidity. The strongest association between NO2 and PEF was observed among the patients treated with salmeterol. Negative associations were also found between PEF and SO2 and between PEF and PM(10), respectively. The results show that the two medication regimens protected against the effects of PM(10). However, salmeterol increased the sensitivity to NO2 and triamcinalone enhanced the sensitivity to SO2.

  11. Desorption of Herbicides from Atmospheric Particulates During High-Volume Air Sampling

    Directory of Open Access Journals (Sweden)

    Dwight V. Quiring

    2011-11-01

    Full Text Available Pesticides can be present in the atmosphere either as vapours and/or in association with suspended particles. High-volume air sampling, in which air is aspirated first through a glass fibre filter to capture pesticides associated with atmospheric particulates and then polyurethane foam (PUF, often in combination with an adsorbent resin such as XAD-2, to capture pesticides present as vapours, is generally employed during atmospheric monitoring for pesticides. However, the particulate fraction may be underestimated because some pesticides may be stripped or desorbed from captured particulates due to the pressure drop created by the high flow of air through the filter. This possibility was investigated with ten herbicide active ingredients commonly used on the Canadian prairies (dimethylamine salts of 2,4-D, MCPA and dicamba, 2,4-D 2-ethylhexyl ester, bromoxynil octanoate, diclofop methyl ester, fenoxaprop ethyl ester, trifluralin, triallate and ethalfluralin and seven hydrolysis products (2,4-D, MCPA, dicamba, bromoxynil, diclofop, clopyralid and mecoprop. Finely ground heavy clay soil fortified with active ingredients/hydrolysis products was evenly distributed on the glass fibre filters of high-volume air samplers and air aspirated through the samplers at a flow rate of 12.5 m3/h for a 7-day period. The proportion desorbed as vapour from the fortified soil was determined by analysis of the PUF/XAD-2 resin composite cartridges. The extent of desorption from the fortified soil applied to the filters varied from 0% for each of the dimethylamine salts of 2,4-D, MCPA and dicamba to approximately 50% for trifluralin, triallate and ethalfluralin.

  12. Wake flow characteristics at high wind speed

    DEFF Research Database (Denmark)

    Aagaard Madsen, Helge; Larsen, Torben J.; Larsen, Gunner Chr.

    2016-01-01

    power. In the present study we simulate the wake flow for a row of turbines with the wind aligned with the row using a simplified approach. The velocity deficit, being a function of the thrust coefficient, is simulated based on the BEM solution for wake expansion. An axis-symmetric boundary layer...... equation model (the same as implemented in the DWM model) is subsequently used to develop the deficit down to the next turbine, and then the approach is successively repeated. Simulation results for four different spacing’s in a row with eight turbines show that there are two major flow regimes...... in the intersection region between the two flow regimes a strong variation in power and thrust occur, e.g. going from almost zero power to rated power for a wind speed change of 4m/s. Another result is that the inflow profile to the last turbine in the row at a wind speed of 16m/s for a spacing of 3D shows...

  13. High flow air sampling for determination of alpha long half-life emitters: area monitoring of a radioactive material disposal; Amostragem de ar de alto fluxo para determinacao de alfa emissores de meia vida longa: monitoracao de area em um deposito de material radioativo

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, W.S. [Industrias Nucleares do Brasil (SR/FCN/INB), Itatiaia, RJ (Brazil). Servico de Radioprotecao. Fabrica do Combustivel Nuclear; Kelecom, A. [Universidade Federal Fluminense (LARARA-PLS/GETA/UFF), Niteroi, RJ (Brazil). Lab. de Radiobiologia e Radiometria Pedro Lopes dos Santos. Grupo de Estudos em Temas Ambientais

    2015-07-01

    The Ore Treatment Unit (UTM) is a mine and closed uranium plant, located in Caldas, Minas Gerais, Brazil. It has a radioactive material disposal composed primarily of pie II and mesothorium. It is stored in six sheds designated C-01, C-02, C-05, C-06, C-07 and C-09. This study aims to present the high flow area monitoring program and results obtained in 2009. The threshold derived from concentration in the air was 0.25 Bq m{sup -3}. The average of the activity concentrations in 2009 were: for C-01 1.17 Bq m{sup -3}; C-02 0.006 Bq m{sup -3}; C-05 1.98 Bq m{sup -3}; C-06 2.14 Bq m{sup -3}; C-07 0.34 Bq m{sup -3} and C-09 0,025 Bq m{sup -3}. Such values indicate that the control stay is an important factor in occupational workers' control, as well as the use of EPI's and behavioral care, besides radioprotection training to allow the access to the areas. No worker, supervisor or visitor reached the limit research.

  14. Gas dispersion and immobile gas volume in solid and porous particle biofilter materials at low air flow velocities.

    Science.gov (United States)

    Sharma, Prabhakar; Poulsen, Tjalfe G

    2010-07-01

    Gas-phase dispersion in granular biofilter materials with a wide range of particle sizes was investigated using atmospheric air and nitrogen as tracer gases. Two types of materials were used: (1) light extended clay aggregates (LECA), consisting of highly porous particles, and (2) gravel, consisting of solid particles. LECA is a commercial material that is used for insulation, as a soil conditioner, and as a carrier material in biofilters for air cleaning. These two materials were selected to have approximately the same particle shape. Column gas transport experiments were conducted for both materials using different mean particle diameters, different particle size ranges, and different gas flow velocities. Measured breakthrough curves were modeled using the advection-dispersion equation modified for mass transfer between mobile and immobile gas phases. The results showed that gas dispersivity increased with increasing mean particle diameter for LECA but was independent of mean particle diameter for gravel. Gas dispersivity also increased with increasing particle size range for both media. Dispersivities in LECA were generally higher than for gravel. The mobile gas content in both materials increased with increasing gas flow velocity but it did not show any strong dependency on mean particle diameter or particle size range. The relative fraction of mobile gas compared with total porosity was highest for gravel and lowest for LECA likely because of its high internal porosity.

  15. 直接空冷单元空气流场优化%Optimization of air flow field for direct air cooling units

    Institute of Scientific and Technical Information of China (English)

    水海波; 汪晓龙; 张涛; 宋艳峰; 陈磊; 席新铭; 杨立军; 杜小泽

    2015-01-01

    直接空冷系统空冷单元空气流场具有明显的旋转上升特点,且呈中心对称分布,使空冷单元翅片管束的冷却空气流量分配极不均匀,翅片管束传热面利用效率低,空冷凝汽器流动传热性能差。对此,利用 CFD 软件,对直接空冷单元内部的空气动力学特性进行研究,发现,由于风机出口流通面积的突变,在空冷单元底部形成了流动死区和涡流,在单元中心形成了严重的回流,导致流动阻力增加,阻碍了风机出口冷却空气向翅片管束方向的顺利流动。为此,提出4种导流方案,对4种导流方案的空冷单元热力性能进行研究。结果表明,经过空冷单元内冷却空气导流后,空气流场得到优化,管束表面流量和温度场更为均匀,空冷单元流动传热性能得到了改善。4种导流方案中,方案3的效果最为显著。%The air flow field of air cooling unit in direct air cooling systems has dramatic spiral trend and is cen-trosymmetric distributed,resulting in a very uneven distribution of cooling air volume in finned tube bundles,a real-ly low utilization efficiency of the heating surface of finned tubes and quite poor flow and heat transfer performance of air cooled condenser.Thus,the CFD software was applied to investigate the dynamic characteristics of air flow field inside the direct air cooling unit.It finds that due to sudden change of flow area at the fan outlet,flow dead zone and vortexes form at the air cooling unit bottom and serious reflux occurs in the unit center,causing an increase in flow resistance,which impedes the cooling air to flow from the fan outlet toward the finned tube bundles.There-fore,four flow guidance schemes were put forward and thermal performance of the air cooling unit in these four schemes were analyzed.The results show that,after guidance of the cooling air inside the air cooling unit,the air flow field is optimized,the bundles

  16. Numerical Analysis of Flow Distribution in a Sodium Chamber of a Finned-tube Sodium-to-Air Heat Exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Youngchul; Son, Seokkwon; Kim, Hyungmo; Eoh, Jaehyuk; Jeong, Jiyoung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    DHR systems consist of two diverse heat removal loops such as passive and active DHR systems, and the heat load imposed on the primary sodium pool is safely rejected into the environment through different kinds of sodium-to-air heat exchangers, e.g. M-shape and helical-coil type air-coolers. The former is called as an FHX(Forced-draft sodium-to-air Heat Exchanger) and the latter is simply called as an AHX(natural-draft sodium-to-Air Heat Exchanger). In a general sodium-to-air heat exchanger design, convection resistance in a shell-side air flow path becomes dominant factor affecting the mechanism of conjugate heat transfer from the sodium flow inside the tube to the air path across the sodium tube wall. Hence verification of the flow and heat transfer characteristics is one of the most important tasks to demonstrate decay heat removal performance. To confirm a kind of ultimate heat sink heat exchanger, a medium-scale Sodium thermal-hydraulic Experiment Loop for Finned-tube sodium-to-Air Heat exchanger (here after called the SELFA) has been designed and is recently being constructed at KAERI site. The introduction of the flow baffle inside the upper sodium chamber of the model FHX unit in the SELFA facility is briefly proposed and discussed as well. The present study aims at introducing a flow baffle design inside the upper sodium chamber to make more equalized flowrates flowing into each heat transfer tube of the model FHX unit. In the cases without the flow baffle geometry, it was observed lager discrepancies in flowrates at the heat transfer tubes. However it was also found that those kinds of discrepancies could be definitely decreased at around 1/10 by employing a flow baffle.

  17. High Technology Centrifugal Compressor for Commercial Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ruckes, John

    2006-04-15

    R&D Dynamics, Bloomfield, CT in partnership with the State of Connecticut has been developing a high technology, oil-free, energy-efficient centrifugal compressor called CENVA for commercial air conditioning systems under a program funded by the US Department of Energy. The CENVA compressor applies the foil bearing technology used in all modern aircraft, civil and military, air conditioning systems. The CENVA compressor will enhance the efficiency of water and air cooled chillers, packaged roof top units, and other air conditioning systems by providing an 18% reduction in energy consumption in the unit capacity range of 25 to 350 tons of refrigeration The technical approach for CENVA involved the design and development of a high-speed, oil-free foil gas bearing-supported two-stage centrifugal compressor, CENVA encompassed the following high technologies, which are not currently utilized in commercial air conditioning systems: Foil gas bearings operating in HFC-134a; Efficient centrifugal impellers and diffusers; High speed motors and drives; and System integration of above technologies. Extensive design, development and testing efforts were carried out. Significant accomplishments achieved under this program are: (1) A total of 26 builds and over 200 tests were successfully completed with successively improved designs; (2) Use of foil gas bearings in refrigerant R134a was successfully proven; (3) A high speed, high power permanent magnet motor was developed; (4) An encoder was used for signal feedback between motor and controller. Due to temperature limitations of the encoder, the compressor could not operate at higher speed and in turn at higher pressure. In order to alleviate this problem a unique sensorless controller was developed; (5) This controller has successfully been tested as stand alone; however, it has not yet been integrated and tested as a system; (6) The compressor successfully operated at water cooled condensing temperatures Due to temperature

  18. Propagation of atmospheric pressure helium plasma jet into ambient air at laminar gas flow

    Science.gov (United States)

    Pinchuk, M.; Stepanova, O.; Kurakina, N.; Spodobin, V.

    2017-05-01

    The formation of an atmospheric pressure plasma jet (APPJ) in a gas flow passing through the discharge gap depends on both gas-dynamic properties and electrophysical parameters of the plasma jet generator. The paper presents the results of experimental and numerical study of the propagation of the APPJ in a laminar flow of helium. A dielectric-barrier discharge (DBD) generated inside a quartz tube equipped with a coaxial electrode system, which provided gas passing through it, served as a plasma source. The transition of the laminar regime of gas flow into turbulent one was controlled by the photography of a formed plasma jet. The corresponding gas outlet velocity and Reynolds numbers were revealed experimentally and were used to simulate gas dynamics with OpenFOAM software. The data of the numerical simulation suggest that the length of plasma jet at the unvarying electrophysical parameters of DBD strongly depends on the mole fraction of ambient air in a helium flow, which is established along the direction of gas flow.

  19. The impact of traffic-flow patterns on air quality in urban street canyons.

    Science.gov (United States)

    Thaker, Prashant; Gokhale, Sharad

    2016-01-01

    We investigated the effect of different urban traffic-flow patterns on pollutant dispersion in different winds in a real asymmetric street canyon. Free-flow traffic causes more turbulence in the canyon facilitating more dispersion and a reduction in pedestrian level concentration. The comparison of with and without a vehicle-induced-turbulence revealed that when winds were perpendicular, the free-flow traffic reduced the concentration by 73% on the windward side with a minor increase of 17% on the leeward side, whereas for parallel winds, it reduced the concentration by 51% and 29%. The congested-flow traffic increased the concentrations on the leeward side by 47% when winds were perpendicular posing a higher risk to health, whereas reduced it by 17-42% for parallel winds. The urban air quality and public health can, therefore, be improved by improving the traffic-flow patterns in street canyons as vehicle-induced turbulence has been shown to contribute significantly to dispersion.

  20. Liquid-phase turbulence measurements in air-water two-phase flows over a wide range of void fractions

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xinquan [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, 201 W. 19th Ave., Columbus, OH 43210 (United States); Sun, Xiaodong, E-mail: sun.200@osu.edu [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, 201 W. 19th Ave., Columbus, OH 43210 (United States); Liu, Yang [Nuclear Engineering Program, Department of Mechanical Engineering, Virginia Tech, 635 Prices Fork Road, Blacksburg, VA 24061 (United States)

    2016-12-15

    This paper focuses on liquid-phase turbulence measurements in air-water two-phase flows over a wide range of void fractions and flow regimes, spanning from bubbly, cap-bubbly, slug, to churn-turbulent flows. The measurements have been conducted in two test facilities, the first one with a circular test section and the second one with a rectangular test section. A particle image velocimetry-planar laser-induced fluorescence (PIV-PLIF) system was used to acquire local liquid-phase turbulence information, including the time-averaged velocity and velocity fluctuations in the streamwise and spanwise directions, and Reynolds stress. An optical phase separation method using fluorescent particles and optical filtration technique was adopted to extract the liquid-phase velocity information. An image pre-processing scheme was imposed on the raw PIV images acquired to remove noise due to the presence of bubble residuals and optically distorted particles in the raw PIV images. Four-sensor conductivity probes and high-speed images were also used to acquire the gas-phase information, which was aimed to understand the flow interfacial structure. The highest area-averaged void fraction covered in the measurements for the circular and rectangular test sections was about 40%.

  1. Observations of internal flow inside an evaporating nanofluid sessile droplet in the presence of an entrapped air bubble

    Science.gov (United States)

    Shin, Dong Hwan; Allen, Jeffrey S.; Lee, Seong Hyuk; Choi, Chang Kyoung

    2016-09-01

    Using a unique, near-field microscopy technique, fringe patterns and nanoparticle motions are visualized immediately following a nanofluid droplet deposition on a glass substrate in which an air bubble is entrapped. The nanofluid consists of DI-water, 0.10% Aluminum Oxide nanoparticles with an average diameter of 50 nm, and 0.0005% yellow-green polystyrene fluorescent particles of 1 μm diameter. High-speed, fluorescent-mode confocal imaging enables investigation of depth-wise sectioned particle movements in the nanofluid droplet inside which a bubble is entrapped. The static contact angle is increased when a bubble is applied. In the presence of the bubble in the droplet, the observed flow toward the center of the droplet is opposite to the flow observed in a droplet without the bubble. When the bubble is present, the evaporation process is retarded. Also, random motion is observed in the contact line region instead of the typical evaporation-driven flow toward the droplet edge. Once the bubble bursts, however, the total evaporation time decreases due to the change in the contact line characteristics. Moreover, the area of fringe patterns beneath the bubble increases with time. Discussed herein is a unique internal flow that has not been observed in nanofluid droplet evaporation.

  2. On the spatial linear growth of gravity-capillary water waves sheared by a laminar air flow

    NARCIS (Netherlands)

    Tsai, Y.S.; Grass, A.J.; Simons, R.R.

    2005-01-01

    The initial growth of mechanically generated small amplitude water waves below a laminar air stream was examined numerically and experimentally in order to explore the primary growth mechanism, that is, the interfacial instability of coupled laminar air and water flows. Measurements of the laminar v

  3. An investigation of channel flow with a smooth air-water interface

    Science.gov (United States)

    Madad, Reza; Elsnab, John; Chin, Cheng; Klewicki, Joseph; Marusic, Ivan

    2015-06-01

    Experiments and numerical simulation are used to investigate fully developed laminar and turbulent channel flow with an air-water interface as the lower boundary condition. Laser Doppler velocimetry measurements of streamwise and wall-normal velocity components are made over a range of Reynolds number based upon channel height and bulk velocity from 1100 to 4300, which encompasses the laminar, transitional and low Reynolds numbers turbulent regimes. The results show that the airflow statistics near the stationary wall are not significantly altered by the air-water moving interface and reflect those found in channel flows. The mean statistics on the water interface side largely exhibit results similar to simulated Poiseuille-Couette flow (PCF) with a solid moving wall. For second-order statistics, however, the simulation and experimental results show some discrepancies near the moving water surface, suggesting that a full two-phase simulation is required. A momentum and energy transport tubes analysis is investigated for laminar and turbulent PCFs. This analysis builds upon the classical notion of a streamtube and indicates that part of the energy from the pressure gradient is transported towards the stationary wall and is dissipated as heat inside the energy tubes, while the remainder is transmitted to the moving wall. For the experiments, the airflow energy is transmitted towards the water to overcome the drag force and drive the water forward; therefore, the amount of energy transferred to the water is higher than the energy transferred to a solid moving wall.

  4. Mechanical Design of a Performance Test Rig for the Turbine Air-Flow Task (TAFT)

    Science.gov (United States)

    Xenofos, George; Forbes, John; Farrow, John; Williams, Robert; Tyler, Tom; Sargent, Scott; Moharos, Jozsef

    2003-01-01

    To support development of the Boeing-Rocketdyne RS84 rocket engine, a fill-flow, reaction turbine geometry was integrated into the NASA-MSFC turbine air-flow test facility. A mechanical design was generated which minimized the amount of new hardware while incorporating all test and instrUmentation requirements. This paper provides details of the mechanical design for this Turbine Air-Flow Task (TAFT) test rig. The mechanical design process utilized for this task included the following basic stages: Conceptual Design. Preliminary Design. Detailed Design. Baseline of Design (including Configuration Control and Drawing Revision). Fabrication. Assembly. During the design process, many lessons were learned that should benefit future test rig design projects. Of primary importance are well-defined requirements early in the design process, a thorough detailed design package, and effective communication with both the customer and the fabrication contractors. The test rig provided steady and unsteady pressure data necessary to validate the computational fluid dynamics (CFD) code. The rig also helped characterize the turbine blade loading conditions. Test and CFD analysis results are to be presented in another JANNAF paper.

  5. Prediction of Air Flow and Temperature Profiles Inside Convective Solar Dryer

    Directory of Open Access Journals (Sweden)

    Marian Vintilă

    2014-11-01

    Full Text Available Solar tray drying is an effective alternative for post-harvest processing of fruits and vegetables. Product quality and uniformity of the desired final moisture content are affected by the uneven air flow and temperature distribution inside the drying chamber. The purpose of this study is to numerically evaluate the operation parameters of a new indirect solar dryer having an appropriate design based on thermal uniformity inside the drying chamber, low construction costs and easy accessibility to resources needed for manufacture. The research was focused on both the investigation of different operation conditions and analysis of the influence of the damper position, which is incorporated into the chimney, on the internal cabinet temperature and air flow distribution. Numerical simulation was carried out with Comsol Multiphysics CFD commercial code using a reduced 2D domain model by neglecting any end effects from the side walls. The analysis of the coupled thermal-fluid model provided the velocity field, pressure distribution and temperature distribution in the solar collector and in the drying chamber when the damper was totally closed, half open and fully open and for different operation conditions. The predicted results were compared with measurements taken in-situ. With progressing computing power, it is conceivable that CFD will continue to provide explanations for more fluid flow, heat and mass transfer phenomena, leading to better equipment design and process control for the food industry.

  6. Flow pattern, void fraction and pressure drop of two-phase air-water flow in a horizontal circular micro-channel

    Energy Technology Data Exchange (ETDEWEB)

    Saisorn, Sira [Energy Division, The Joint Graduate School of Energy and Environment (JGSEE), King Mongkut' s University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand); Wongwises, Somchai [Fluid Mechanics, Thermal Engineering and Multiphase Flow Research Laboratory (FUTURE), Department of Mechanical Engineering, King Mongkut' s University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand)

    2008-01-15

    Adiabatic two-phase air-water flow characteristics, including the two-phase flow pattern as well as the void fraction and two-phase frictional pressure drop, in a circular micro-channel are experimentally studied. A fused silica channel, 320 mm long, with an inside diameter of 0.53 mm is used as the test section. The test runs are done at superficial velocity of gas and liquid ranging between 0.37-16 and 0.005-3.04 m/s, respectively. The flow pattern map is developed from the observed flow patterns i.e. slug flow, throat-annular flow, churn flow and annular-rivulet flow. The flow pattern map is compared with those of other researchers obtained from different working fluids. The present single-phase experiments also show that there are no significant differences in the data from the use of air or nitrogen gas, and water or de-ionized water. The void fraction data obtained by image analysis tends to correspond with the homogeneous flow model. The two-phase pressure drops are also used to calculate the frictional multiplier. The multiplier data show a dependence on flow pattern as well as mass flux. A new correlation of two-phase frictional multiplier is also proposed for practical application. (author)

  7. Hot-wire air flow meter for gasoline fuel-injection system. Calculation of air mass in cylinder during transient condition; Gasoline funsha system yo no netsusenshiki kuki ryuryokei. Kato untenji no cylinder juten kukiryo no keisan

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Y. [Hitachi Car Engineering, Ltd., Tokyo (Japan); Nishimura, Y.; Osuga, M.; Yamauchi, T. [Hitachi, Ltd., Tokyo (Japan)

    1997-10-01

    Air flow characteristics of hot-wire air flow meters for gasoline fuel-injection systems with supercharging and exhaust gas recycle during transient conditions were investigated to analyze a simple method for calculating air mass in cylinder. It was clarified that the air mass in cylinder could be calculated by compensating for the change of air mass in intake system by using aerodynamic models of intake system. 3 refs., 6 figs., 1 tab.

  8. Experimental investigation on a high subsonic compressor cascade flow

    Directory of Open Access Journals (Sweden)

    Zhang Haideng

    2015-08-01

    Full Text Available With the aim of deepening the understanding of high-speed compressor cascade flow, this paper reports an experimental study on NACA-65 K48 compressor cascade with high subsonic inlet flow. With the increase of passage pressurizing ability, endwall boundary layer behavior is deteriorated, and the transition zone is extended from suction surface to the endwall as the adverse pressure gradient increases. Cross flow from endwall to midspan, mixing of corner boundary layer and the main stream, and reversal flow on the suction surface are caused by corner separation vortex structures. Passage vortex is the main corner separation vortex. During its movement downstream, the size grows bigger while the rotating direction changes, forming a limiting circle. With higher incidence, corner separation is further deteriorated, leading to higher flow loss. Meanwhile, corner separation structure, flow mixing characteristics and flow loss distribution vary a lot with the change of incidence. Compared with low aspect-ratio model, corner separation of high aspect-ratio model moves away from the endwall and is more sufficiently developed downstream the cascade. Results obtained present details of high-speed compressor cascade flow, which is rare in the relating research fields and is beneficial to mechanism analysis, aerodynamic optimization and flow control design.

  9. Computation of air and fuel droplet flows in S.I. engine manifolds

    Science.gov (United States)

    Chen, P. Y. P.; Behnia, M.; Milton, B. E.

    The flow of air and fuel mixture similar to that in the induction systems of an Sl engine has been studied. A standard, general purpose single phase CFD code was used with some modifications to account for momentum, mass and heat transfers between the air stream and fuel droplets. Based on a Lagrangian approach, the movement from an assumed spray distribution model of fuel droplets were individually tracked. Models using different assumed coupling between the two phases have been investigated. Under typical engine operating conditions, it was found that a fully coupled treatment for momentum is not required. For estimation of fuel evaporation, a computing time saving one-dimensional treatment was found to be adequate. Fuel film formation on various surfaces of a duct and butterfly valve simulating an engine manifold is reported.

  10. Adaptive inverse control of air supply flow for proton exchange membrane fuel cell systems

    Institute of Scientific and Technical Information of China (English)

    LI Chun-hua; ZHU Xin-jian; SUI Sheng; HU Wan-qi; HU Ming-ruo

    2009-01-01

    To prevent the oxygen starvation and improve the system output performance, an adaptive inverse control (AIC) strategy is developed to regulate the air supply flow of a proton exchange membrane fuel cell (PEMFC) system in this paper.The PEMFC stack and the air supply system including a compressor and a supply manifold are modeled for the purpose of performance analysis and controller design. A recurrent fuzzy neural network (RFNN) is utilized to identify the inverse model of the controlled system and generates a suitable control input during the abrupt step change of external disturbances.Compared with the PI controller, numerical simulations are performed to validate the effectiveness and advantages of the proposed AIC strategy.

  11. Correlation of Spherical Thermistor for the Measurement of Low Velocity Air Flow

    Institute of Scientific and Technical Information of China (English)

    Xin-GangLiang; Ying-PingZhang; 等

    1998-01-01

    A spherical thermistor,an accurate temperature sensor is employed as an air velocity sensor in this work.The measuring principle is derived and the effects of the insulation layer,air temperature,netural convection and thermal radiation are discussed.Two different correlation relations for velocity measurements are proposed based on theoretical analyses and experimental calibrations,Experiments have shown that spherical thermistor is a good velocity sensor for speed between 0.1-2.5m/s at room temperature and the insulation layer hardly influences the accuracy of the thermistor used in the present work,Modification of correlation can even further imporve measurement accuracy.Since the thermistor is small and cheap,it is possible to apply this method to multi-Point velocity measurement with a low disturbance to the flow field.

  12. Three-dimensional flow field of a rectangular array of practical air jets

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed, A.; Shambaugh, R.L. (Univ. of Oklahoma, Norman (United States))

    1993-05-01

    A number of recent investigators have examined the flow fields of practical nozzles used in industry. Past investigators considered only single nozzles. This present paper concerns the velocity field below an array of practical nozzles. A common industrial use of such an array is the production of fine polymeric fibers by the process known as melt blowing. The velocity field was measured below a rectangular array of 165 air nozzles. The array was arranged in a rectangular pattern with three side-by-side columns. All nozzles were identical. Each nozzle had a sharp-edged inlet, and each nozzle discharged air through an area that approximated an annulus. Based on momentum conservation considerations, a single equation was developed that fits the data well and can be used to predict the velocity at any position below the nozzle array. At large distances from the array, the velocity field can be approximated as the field of a two-dimensional jet.

  13. High-Performance Sorbents for Carbon Dioxide Capture from Air

    Energy Technology Data Exchange (ETDEWEB)

    Sholl, David; Jones, Christopher

    2013-03-13

    This project has focused on capture of CO{sub 2} from ambient air (“air capture”). If this process is technically and economically feasible, it could potentially contribute to net reduction of CO{sub 2} emissions in ways that are complementary to better developed techniques for CO{sub 2} from concentrated point sources. We focused on cyclic adsorption processes for CO{sub 2} capture from air in which the entire cycle is performed at moderate temperatures. The project involved both experimental studies of sorbent materials and process level modeling of cyclic air capture processes. In our experimental work, a series of amine-functionalized silica adsorbents were prepared and characterized to determine the impact of molecular architecture on CO{sub 2} capture. Some key findings were: • Amine functionalized silicas can be prepared with high enough CO{sub 2} capacities under ambient conditions to merit consideration for use in air capture processes. • Primary amines are better candidates for CO{sub 2} capture than secondary or tertiary amines, both in terms of amine efficiency for CO{sub 2} adsorption and enhanced water affinity. • Mechanistic understanding of degradation of these materials can enable control of molecular architecture to significantly improve material stability. Our process modeling work provided the first publically available cost and energy estimates for cyclic adsorption processes for air capture of CO{sub 2}. Some key findings were: • Cycles based on diurnal ambient heating and cooling cannot yield useful purities or amounts of captured CO{sub 2}. • Cycles based on steam desorption at 110 oC can yield CO{sub 2} purities of ~88%. • The energy requirements for cycles using steam desorption are dominated by needs for thermal input, which results in lower costs than energy input in the form of electricity. Cyclic processes with operational costs of less than $100 tCO{sub 2}-net were described, and these results point to process and

  14. High speed digital holographic interferometry for hypersonic flow visualization

    Science.gov (United States)

    Hegde, G. M.; Jagdeesh, G.; Reddy, K. P. J.

    2013-06-01

    Optical imaging techniques have played a major role in understanding the flow dynamics of varieties of fluid flows, particularly in the study of hypersonic flows. Schlieren and shadowgraph techniques have been the flow diagnostic tools for the investigation of compressible flows since more than a century. However these techniques provide only the qualitative information about the flow field. Other optical techniques such as holographic interferometry and laser induced fluorescence (LIF) have been used extensively for extracting quantitative information about the high speed flows. In this paper we present the application of digital holographic interferometry (DHI) technique integrated with short duration hypersonic shock tunnel facility having 1 ms test time, for quantitative flow visualization. Dynamics of the flow fields in hypersonic/supersonic speeds around different test models is visualized with DHI using a high-speed digital camera (0.2 million fps). These visualization results are compared with schlieren visualization and CFD simulation results. Fringe analysis is carried out to estimate the density of the flow field.

  15. High Resolution Simulation of Turbulent Flow in a Channel.

    Science.gov (United States)

    1987-09-25

    chosen to maintain the original Poiseuille flow . The introduction of highly unstable disturbances causes transition to turbulence so that the wall...for Turbulent Channel Flow ," Phys. Rev. Lett, Vol. 47, 832-835 (1981). 2. S.A. Orszag and L.C. Kells, "Transition to turbulence in plane Poiseuille and...plane Couette Flow ," J. Fluid Mech., Vol. 96, pp. 159-205. 3. Kreplin, H.-P. and Eckelmann, H., "Behavior of the Three Fluctucting Velocity

  16. High-speed flow visualization in hypersonic, transonic, and shock tube flows

    Science.gov (United States)

    Kleine, H.; Olivier, H.

    2017-02-01

    High-speed flow visualisation has played an important role in the investigations conducted at the Stoßwellenlabor of the RWTH Aachen University for many decades. In addition to applying the techniques of high-speed imaging, this laboratory has been actively developing new or enhanced visualisation techniques and approaches such as various schlieren methods or time-resolved Mach-Zehnder interferometry. The investigated high-speed flows are inherently highly transient, with flow Mach numbers ranging from about M = 0.7 to M = 8. The availability of modern high-speed cameras has allowed us to expand the investigations into problems where reduced reproducibility had so far limited the amount of information that could be extracted from a limited number of flow visualisation records. Following a brief historical overview, some examples of recent studies are given, which represent the breadth of applications in which high-speed imaging has been an essential diagnostic tool to uncover the physics of high-speed flows. Applications include the stability of hypersonic corner flows, the establishment of shock wave systems in transonic airfoil flow, and the complexities of the interactions of shock waves with obstacles of various shapes.

  17. Development of a Pulsed Combustion Actuator For High-Speed Flow Control

    Science.gov (United States)

    Cutler, Andrew D.; Beck, B. Terry; Wilkes, Jennifer A.; Drummond, J. Philip; Alderfer, David W.; Danehy, Paul M.

    2005-01-01

    This paper describes the flow within a prototype actuator, energized by pulsed combustion or detonations, that provides a pulsed jet suitable for flow control in high-speed applications. A high-speed valve, capable of delivering a pulsed stream of reactants a mixture of H2 and air at rates of up to 1500 pulses per second, has been constructed. The reactants burn in a resonant chamber, and the products exit the device as a pulsed jet. High frequency pressure transducers have been used to monitor the pressure fluctuations in the device at various reactant injection frequencies, including both resonant and off-resonant conditions. The combustion chamber has been constructed with windows, and the flow inside it has been visualized using Planar Laser-Induced Fluorescence (PLIF). The pulsed jet at the exit of the device has been observed using schlieren.

  18. A cost-effective method for simulating city-wide air flow and pollutant dispersion at building resolving scale

    Science.gov (United States)

    Berchet, Antoine; Zink, Katrin; Muller, Clive; Oettl, Dietmar; Brunner, Juerg; Emmenegger, Lukas; Brunner, Dominik

    2017-06-01

    A cost-effective method is presented allowing to simulate the air flow and pollutant dispersion in a whole city over multiple years at the building-resolving scale with hourly time resolution. This combination of high resolution and long time span is critically needed for epidemiological studies and for air pollution control, but still poses a great challenge for current state-of-the-art modelling techniques. The presented method relies on the pre-computation of a discrete set of possible weather situations and corresponding steady-state flow and dispersion patterns. The most suitable situation for any given hour is then selected by matching the simulated wind patterns to meteorological observations in and around the city. The catalogue of pre-computed situations corresponds to different large-scale forcings in terms of wind speed, wind direction and stability. A meteorological model converts these forcings into realistic mesoscale flow patterns accounting for the effects of topography and land-use contrasts in a domain covering the city and its surroundings. These mesoscale patterns serve as boundary conditions for a microscale urban flow model which finally drives a Lagrangian air pollutant dispersion model. The method is demonstrated with the modelling system GRAMM/GRAL v14.8 for two Swiss cities in complex terrain, Zurich and Lausanne. The mesoscale flow patterns in the two regions of interest, dominated by land-lake breezes and driven by the partly steep topography, are well reproduced in the simulations matched to in situ observations. In particular, the combination of wind measurements at different locations around the city appeared to be a robust approach to deduce the stability class for the boundary layer within the city. This information is critical for predicting the temporal variability of pollution concentration within the city, regarding their relationship with the intensity of horizontal and vertical dispersion and of turbulence. In the vicinity of

  19. Validation of AIRS high-resolution stratospheric temperature retrievals

    Science.gov (United States)

    Meyer, Catrin I.; Hoffmann, Lars

    2014-10-01

    This paper focuses on stratospheric temperature observations by the Atmospheric InfraRed Sounder (AIRS) aboard NASA's Aqua satellite. We validate a nine-year record (2003 - 2011) of data retrieved with a scientific retrieval processor independent from the operational processor operated by NASA. The retrieval discussed here provides stratospheric temperature profiles for each individual AIRS footprint and has nine times better horizontal sampling than the operational data provided by NASA. The high-resolution temperature data are considered optimal for for gravity wave studies. For validation the high-resolution retrieval data are compared with results from the AIRS operational Level-2 data and the ERA-Interim meteorological reanalysis. Due to the large amount of data we performed statistical comparisons of monthly zonal mean cross-sections and time series. The comparisons show that the high-resolution temperature data are in good agreement with the validation data sets. The bias in the zonal averages is mostly within ±2K. The bias reaches a maximum of 7K to ERA-Interim and 4K to the AIRS operational data at the stratopause, it is related to the different resolutions of the data sets. Variability is nearly the same in all three data sets, having maximum standard deviations around the polar vortex in the mid and upper stratosphere. The validation presented here indicates that the high-resolution temperature retrievals are well-suited for scientific studies. In particular, we expect that they will become a valuable asset for future studies of stratospheric gravity waves.

  20. High energy density redox flow device

    Energy Technology Data Exchange (ETDEWEB)

    Carter, W. Craig; Chiang, Yet-Ming; Duduta, Mihai; Limthongkul, Pimpa

    2017-04-04

    Redox flow devices are described including a positive electrode current collector, a negative electrode current collector, and an ion-permeable membrane separating said positive and negative current collectors, positioned and arranged to define a positive electroactive zone and a negative electroactive zone; wherein at least one of said positive and negative electroactive zone comprises a flowable semi-solid composition comprising ion storage compound particles capable of taking up or releasing said ions during operation of the cell, and wherein the ion storage compound particles have a polydisperse size distribution in which the finest particles present in at least 5 vol % of the total volume, is at least a factor of 5 smaller than the largest particles present in at least 5 vol % of the total volume.

  1. Unusually high soil nitrogen oxide emissions influence air quality in a high-temperature agricultural region.

    Science.gov (United States)

    Oikawa, P Y; Ge, C; Wang, J; Eberwein, J R; Liang, L L; Allsman, L A; Grantz, D A; Jenerette, G D

    2015-11-10

    Fertilized soils have large potential for production of soil nitrogen oxide (NOx=NO+NO2), however these emissions are difficult to predict in high-temperature environments. Understanding these emissions may improve air quality modelling as NOx contributes to formation of tropospheric ozone (O3), a powerful air pollutant. Here we identify the environmental and management factors that regulate soil NOx emissions in a high-temperature agricultural region of California. We also investigate whether soil NOx emissions are capable of influencing regional air quality. We report some of the highest soil NOx emissions ever observed. Emissions vary nonlinearly with fertilization, temperature and soil moisture. We find that a regional air chemistry model often underestimates soil NOx emissions and NOx at the surface and in the troposphere. Adjusting the model to match NOx observations leads to elevated tropospheric O3. Our results suggest management can greatly reduce soil NOx emissions, thereby improving air quality.

  2. An investigation of turbulent catalytically stabilized channel flow combustion of lean hydrogen - air mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Mantzaras, I.; Benz, P.; Schaeren, R.; Bombach, R. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    The catalytically stabilised thermal combustion (CST) of lean hydrogen-air mixtures was investigated numerically in a turbulent channel flow configuration using a two-dimensional elliptic model with detailed heterogeneous and homogeneous chemical reactions. Comparison between turbulent and laminar cases having the same incoming mean properties shows that turbulence inhibits homogeneous ignition due to increased heat transport away from the near-wall layer. The peak root-mean-square temperature and species fluctuations are always located outside the extent of the homogeneous reaction zone indicating that thermochemical fluctuations have no significant influence on gaseous combustion. (author) 4 figs., 6 refs.

  3. Study on law of negative corona discharge in microparticle-air two-phase flow media

    Directory of Open Access Journals (Sweden)

    Bo He

    2016-03-01

    Full Text Available To study the basic law of negative corona discharge in solid particle-air two-phase flow, corona discharge experiments in a needle-plate electrode system at different voltage levels and different wind speed were carried out in the wind tunnel. In this paper, the change law of average current and current waveform were analyzed, and the observed phenomena were systematically explained from the perspectives of airflow, particle charging, and particle motion with the help of PIV (particle image velocity measurements and ultraviolet observations.

  4. Integrated LTCC Pressure/Flow/Temperature Multisensor for Compressed Air Diagnostics†

    Science.gov (United States)

    Fournier, Yannick; Maeder, Thomas; Boutinard-Rouelle, Grégoire; Barras, Aurélie; Craquelin, Nicolas; Ryser, Peter

    2010-01-01

    We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g., as a standard electronic component would be on a printed circuit board, obviating the need for both wires and tubes and thus paving the road towards low-cost integrated electro-fluidic systems. Several performance aspects of this device are presented and discussed, together with electronics design issues. PMID:22163518

  5. Integrated LTCC pressure/flow/temperature multisensor for compressed air diagnostics.

    Science.gov (United States)

    Fournier, Yannick; Maeder, Thomas; Boutinard-Rouelle, Grégoire; Barras, Aurélie; Craquelin, Nicolas; Ryser, Peter

    2010-01-01

    We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g., as a standard electronic component would be on a printed circuit board, obviating the need for both wires and tubes and thus paving the road towards low-cost integrated electro-fluidic systems. Several performance aspects of this device are presented and discussed, together with electronics design issues.

  6. Heat transfer and pressure drop for air flow through enhanced passages. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Obot, N.T.; Esen, E.B.

    1992-06-01

    An extensive experimental investigation was carried out to determine the pressure drop and heat transfer characteristics for laminar, transitional and turbulent flow of air through a smooth passage and twenty-three enhanced passages. The internal surfaces of all enhanced passages had spirally shaped geometries; these included fluted, finned/ribbed and indented surfaces. The Reynolds number (Re) was varied between 400 and 50000. The effect of heat transfer (wall cooling or fluid heating) on pressure drop is most significant within the transition region; the recorded pressure drop with heat transfer is much higher than that without heat transfer. The magnitude of this effect depends markedly on the average surface temperature and, to a lesser extent, on the geometric characteristics of the enhanced surfaces. When the pressure drop data are reduced as values of the Fanning friction factor(f), the results are about the same with and without heat transfer for turbulent flow, with moderate differences in the laminar and transition regions.

  7. Heat transfer and pressure drop for air flow through enhanced passages

    Energy Technology Data Exchange (ETDEWEB)

    Obot, N.T.; Esen, E.B.

    1992-06-01

    An extensive experimental investigation was carried out to determine the pressure drop and heat transfer characteristics for laminar, transitional and turbulent flow of air through a smooth passage and twenty-three enhanced passages. The internal surfaces of all enhanced passages had spirally shaped geometries; these included fluted, finned/ribbed and indented surfaces. The Reynolds number (Re) was varied between 400 and 50000. The effect of heat transfer (wall cooling or fluid heating) on pressure drop is most significant within the transition region; the recorded pressure drop with heat transfer is much higher than that without heat transfer. The magnitude of this effect depends markedly on the average surface temperature and, to a lesser extent, on the geometric characteristics of the enhanced surfaces. When the pressure drop data are reduced as values of the Fanning friction factor(f), the results are about the same with and without heat transfer for turbulent flow, with moderate differences in the laminar and transition regions.

  8. Research in high flow therapy: mechanisms of action.

    Science.gov (United States)

    Dysart, Kevin; Miller, Thomas L; Wolfson, Marla R; Shaffer, Thomas H

    2009-10-01

    Recently, heater/humidifier devices that use novel methods to condition breathing gases from an external source have been introduced. The addition of sufficient warmth and high levels of humidification to breathing gas has allowed for higher flow rates from nasal cannula devices to be applied to patients (i.e., high flow therapy). This article provides a review of the proposed mechanisms behind the efficacy of high flow therapy via nasal cannula, which include washout of nasopharyngeal dead space, attenuation of the inspiratory resistance associated with the nasopharynx, improvement in conductance and pulmonary compliance, mild distending pressure and reduction in energy expenditure for gas conditioning.

  9. Modeling of high speed micro rotors in moderate flow confinement

    NARCIS (Netherlands)

    Dikmen, E.; Hoogt, van der P.J.M.; Aarts, R.G.K.M.

    2008-01-01

    The recent developments in high speed micro rotating machinery lead to the need for multiphysical modeling of the rotor and the surrounding medium. In this study, thermal and flow induced effects on rotor dynamics of geometries with moderate flow confinement are studied. The structure is modeled via

  10. Stereoscopic PIV measurements of flow in the nasal cavity with high flow therapy

    Science.gov (United States)

    Spence, C. J. T.; Buchmann, N. A.; Jermy, M. C.; Moore, S. M.

    2011-04-01

    Knowledge of the airflow characteristics within the nasal cavity with nasal high flow (NHF) therapy and during unassisted breathing is essential to understand the treatment's efficacy. The distribution and velocity of the airflow in the nasal cavity with and without NHF cannula flow has been investigated using stereoscopic particle image velocimetry at steady peak expiration and inspiration. In vivo breathing flows were measured and dimensionally scaled to reproduce physiological conditions in vitro. A scaled model of the complete nasal cavity was constructed in transparent silicone and airflow simulated with an aqueous glycerine solution. NHF modifies nasal cavity flow patterns significantly, altering the proportion of inspiration and expiration through each passageway and producing jets with in vivo velocities up to 17.0 ms-1 for 30 l/min cannula flow. Velocity magnitudes differed appreciably between the left and right sides of the nasal cavity. The importance of using a three-component measurement technique when investigating nasal flows has been highlighted.

  11. Simultaneous measurement of temperature and velocity of air flow over 1000°C using two color phosphor thermometry

    Science.gov (United States)

    Fukuta, Masatoshi; Someya, Satoshi; Munakata, Tetsuo; LCS Team

    2016-11-01

    Thermal barrier coatings were applied to the gas turbines and the internal combustion engines for the high thermal efficiency. The evaluation and the improvement of coatings require to measure transient gaseous flow near the wall with coatings. An aim of this study is to combine a two color phosphor thermometry with the PIV to measure simultaneously temperature and velocity of the gas over 1000°C. The temperature and velocity distribution of an impinging jet of high temperature air was simultaneously visualized in experiments. The temperature was estimated from an intensity ratio of luminescent in different ranges of wavelength, 500 600 nm and 400 480 nm. Uncertainty of measured temperature was less than 10°C. Temperatures measured by the developed method and by thermocouples were agreed well. The measured velocity by the PIV with phosphor particles were also agreed well with the velocity measured by a Laser Doppler Velocimeter.

  12. A model of particle removal in a dissolved air flotation tank: importance of stratified flow and bubble size.

    Science.gov (United States)

    Lakghomi, B; Lawryshyn, Y; Hofmann, R

    2015-01-01

    An analytical model and a computational fluid dynamic model of particle removal in dissolved air flotation were developed that included the effects of stratified flow and bubble-particle clustering. The models were applied to study the effect of operating conditions and formation of stratified flow on particle removal. Both modeling approaches demonstrated that the presence of stratified flow enhanced particle removal in the tank. A higher air fraction was shown to be needed at higher loading rates to achieve the same removal efficiency. The model predictions showed that an optimum bubble size was present that increased with an increase in particle size.

  13. The main technical progress directions in air-jet engine design branch, which are worked out by the “Single theory of continuous flow propulsions”

    Directory of Open Access Journals (Sweden)

    Борис Шамшадович Мамедов

    2016-03-01

    Full Text Available The main technical progress directions in air-jet engine design branch, which are worked out by the “Single theory of continuous flow propulsions” are highlighted. They are connected with providing the fly security by air-jet engines gas-dynamic work steady increasing with full elimination zone of rigid (spring stroke in the cross section B-B of the air-jet engines, with bypass turbojet engine’s thrust increasing with simultaneously fuel consumption lowering, with inlet and outlet decibel characteristic and radial dementias lowering, with high pressure compressor’s last working wheels blades increasing, with regulating law air-jet engine’s introduction to provide maximum thrust with the purpose of flying (thrust efficiency increasing

  14. Core surface flow modelling from high-resolution secular variation

    DEFF Research Database (Denmark)

    Holme, R.; Olsen, Nils

    2006-01-01

    -flux hypothesis, but the spectrum of the SV implies that a conclusive test of frozen-flux is not possible. We parametrize the effects of diffusion as an expected misfit in the flow prediction due to departure from the frozen-flux hypothesis; at low spherical harmonic degrees, this contribution dominates...... the expected departure of the SV predictions from flow to the observed SV, while at high degrees the SV model uncertainty is dominant. We construct fine-scale core surface flows to model the SV. Flow non-uniqueness is a serious problem because the flows are sufficiently small scale to allow flow around non......-series of magnetic data and better parametrization of the external magnetic field....

  15. Flow "Fine" Synthesis: High Yielding and Selective Organic Synthesis by Flow Methods.

    Science.gov (United States)

    Kobayashi, Shū

    2016-02-18

    The concept of flow "fine" synthesis, that is, high yielding and selective organic synthesis by flow methods, is described. Some examples of flow "fine" synthesis of natural products and APIs are discussed. Flow methods have several advantages over batch methods in terms of environmental compatibility, efficiency, and safety. However, synthesis by flow methods is more difficult than synthesis by batch methods. Indeed, it has been considered that synthesis by flow methods can be applicable for the production of simple gasses but that it is difficult to apply to the synthesis of complex molecules such as natural products and APIs. Therefore, organic synthesis of such complex molecules has been conducted by batch methods. On the other hand, syntheses and reactions that attain high yields and high selectivities by flow methods are increasingly reported. Flow methods are leading candidates for the next generation of manufacturing methods that can mitigate environmental concerns toward sustainable society. © 2015 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  16. High-Density, High-Resolution, Low-Cost Air Quality Sensor Networks for Urban Air Monitoring

    Science.gov (United States)

    Mead, M. I.; Popoola, O. A.; Stewart, G.; Bright, V.; Kaye, P.; Saffell, J.

    2012-12-01

    Monitoring air quality in highly granular environments such as urban areas which are spatially heterogeneous with variable emission sources, measurements need to be made at appropriate spatial and temporal scales. Current routine air quality monitoring networks generally are either composed of sparse expensive installations (incorporating e.g. chemiluminescence instruments) or higher density low time resolution systems (e.g. NO2 diffusion tubes). Either approach may not accurately capture important effects such as pollutant "hot spots" or adequately capture spatial (or temporal) variability. As a result, analysis based on data from traditional low spatial resolution networks, such as personal exposure, may be inaccurate. In this paper we present details of a sophisticated, low-cost, multi species (gas phase, speciated PM, meteorology) air quality measurement network methodology incorporating GPS and GPRS which has been developed for high resolution air quality measurements in urban areas. Sensor networks developed in the Centre for Atmospheric Science (University of Cambridge) incorporated electrochemical gas sensors configured for use in urban air quality studies operating at parts-per-billion (ppb) levels. It has been demonstrated that these sensors can be used to measure key air quality gases such as CO, NO and NO2 at the low ppb mixing ratios present in the urban environment (estimated detection limits work, a state of the art multi species instrument package for deployment in scalable sensor networks has been developed which has general applicability. This is currently being employed as part of a major 3 year UK program at London Heathrow airport (the Sensor Networks for Air Quality (SNAQ) Heathrow project). The main project outcome is the creation of a calibrated, high spatial and temporal resolution data set for O3, NO, NO2, SO2, CO, CO2, VOCstotal, size-speciated PM, temperature, relative humidity, wind speed and direction. The network incorporates existing

  17. Mitigating the Impacts of Uncontrolled Air Flow on Indoor Environmental Quality and Energy Demand in Non-Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hugh I. Henderson; Jensen Zhang; James B. Cummings; Terry Brennan

    2006-07-31

    This multi-faceted study evaluated several aspects of uncontrolled air flows in commercial buildings in both Northern and Southern climates. Field data were collected from 25 small commercial buildings in New York State to understand baseline conditions for Northern buildings. Laboratory wall assembly testing was completed at Syracuse University to understand the impact of typical air leakage pathways on heat and moisture transport within wall assemblies for both Northern and Southern building applications. The experimental data from the laboratory tests were used to verify detailed heat and moisture (HAM) simulation models that could be used to evaluate a wider array of building applications and situations. Whole building testing at FSEC's Building Science Laboratory (BSL) systematically evaluated the energy and IAQ impacts of duct leakage with various attic and ceiling configurations. This systematic test carefully controlled all aspects of building performance to quantify the impact of duct leakage and unbalanced flow. The newest features of the EnergyPlus building simulation tool were used to model the combined impacts of duct leakage, ceiling leakage, unbalanced flows, and air conditioner performance. The experimental data provided the basis to validate the simulation model so it could be used to study the impact of duct leakage over a wide range of climates and applications. The overall objective of this project was to transfer work and knowledge that has been done on uncontrolled air flow in non-residential buildings in Florida to a national basis. This objective was implemented by means of four tasks: (1) Field testing and monitoring of uncontrolled air flow in a sample of New York buildings; (2) Detailed wall assembly laboratory measurements and modeling; (3) Whole building experiments and simulation of uncontrolled air flows; and (4) Develop and implement training on uncontrolled air flows for Practitioners in New York State.

  18. Numerical Investigation of Aeroelastic Mode Distribution for Aircraft Wing Model in Subsonic Air Flow

    Directory of Open Access Journals (Sweden)

    Marianna A. Shubov

    2010-01-01

    Full Text Available In this paper, the numerical results on two problems originated in aircraft wing modeling have been presented. The first problem is concerned with the approximation to the set of the aeroelastic modes, which are the eigenvalues of a certain boundary-value problem. The affirmative answer is given to the following question: can the leading asymptotical terms in the analytical formulas be used as reasonably accurate description of the aeroelastic modes? The positive answer means that these leading terms can be used by engineers for practical calculations. The second problem is concerned with the flutter phenomena in aircraft wings in a subsonic, incompressible, inviscid air flow. It has been shown numerically that there exists a pair of the aeroelastic modes whose behavior depends on a speed of an air flow. Namely, when the speed increases, the distance between the modes tends to zero, and at some speed that can be treated as the flutter speed these two modes merge into one double mode.

  19. Characteristics of aerodynamic sound sources generated by coiled wires in a uniform air-flow

    Science.gov (United States)

    Matsumoto, H.; Nishida, K.; Saitoh, K.

    2003-11-01

    This study deals experimentally with aerodynamic sounds generated by coiled wires in a uniform air-flow. The coiled wire is a model of the hair dryer's heater. In the experiment, the effects of the coil diameter D, wire diameter d and coil spacing s of the coiled wire on the aerodynamic sound have been clarified. The results of frequency analyses of the aerodynamic sounds show that an Aeolian sound is generated by the coiled wire, when s/d is larger than 1. Also the peak frequencies of Aeolian sounds generated by the coiled wires are higher than the ones generated by a straight cylinder having the same diameter d. To clarify the characteristics of the aerodynamic sound sources, the directivity of the aerodynamic sound generated by the coiled wire has been examined, and the coherent function between the velocity fluctuation around the coiled wire and the aerodynamic sound has been calculated. Moreover, the band overall value of coherent output power between the sound and the velocity fluctuations has been calculated. This method has clarified the sound source region of the Aeolian sound generated by the coiled wire. These results show that the Aeolian sound is generated by the arc part of the coiled wire, which is located in the upstream side of the air-flow.

  20. High order Poisson Solver for unbounded flows

    DEFF Research Database (Denmark)

    Hejlesen, Mads Mølholm; Rasmussen, Johannes Tophøj; Chatelain, Philippe

    2015-01-01

    as regularisation we document an increased convergence rate up to tenth order. The method however, can easily be extended well beyond the tenth order. To show the full extend of the method we present the special case of a spectrally ideal regularisation of the velocity formulated integration kernel, which achieves......This paper presents a high order method for solving the unbounded Poisson equation on a regular mesh using a Green’s function solution. The high order convergence was achieved by formulating mollified integration kernels, that were derived from a filter regularisation of the solution field...... or by performing the differentiation as a multiplication of the Fourier coefficients. In this way, differential operators such as the divergence or curl of the solution field could be solved to the same high order convergence without additional computational effort. The method was applied and validated using...

  1. FY-09 Report: Experimental Validation of Stratified Flow Phenomena, Graphite Oxidation, and Mitigation Strategies of Air Ingress Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Chang H. Oh; Eung S. Kim

    2009-12-01

    The Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy, is performing research and development that focuses on key phenomena important during potential scenarios that may occur in the Next Generation Nuclear Plant (NGNP)/Gen-IV very high temperature reactor (VHTR). Phenomena Identification and Ranking Studies to date have identified that an air ingress event following on the heels of a VHTR depressurization is a very important incident. Consequently, the development of advanced air ingress-related models and verification and validation data are a very high priority for the NGNP Project. Following a loss of coolant and system depressurization incident, air will enter the core through the break, leading to oxidation of the in-core graphite structure and fuel. If this accident occurs, the oxidation will accelerate heat-up of the bottom reflector and the reactor core and will eventually cause the release of fission products. The potential collapse of the core bottom structures causing the release of CO and fission products is one of the concerns. Therefore, experimental validation with the analytical model and computational fluid dynamic (CFD) model developed in this study is very important. Estimating the proper safety margin will require experimental data and tools, including accurate multidimensional thermal-hydraulic and reactor physics models, a burn-off model, and a fracture model. It will also require effective strategies to mitigate the effects of oxidation. The results from this research will provide crucial inputs to the INL NGNP/VHTR Methods Research and Development project. The second year of this three-year project (FY-08 to FY-10) was focused on (a) the analytical, CFD, and experimental study of air ingress caused by density-driven, stratified, countercurrent flow; (b) advanced graphite oxidation experiments and modeling; (c) experimental study of burn-off in the core bottom structures, (d) implementation of advanced

  2. Convective high-speed flow and field-aligned high-speed flows explored by TC-1

    Institute of Scientific and Technical Information of China (English)

    ZHANG LingQian; LIU ZhenXing; MA ZhiWei; W.BAUMJOHANN; M.W.DUNLOP4; WANG GuangJun; WANG Xiao; H.REME; C.CARR

    2008-01-01

    From June 1, 2004 to October 31, 2006, a total 465 high-speed flow events are observed by the TC-1 satellite in the near-Earth region (-13 RE < X < -9 RE, |Y|<10 RE, |2|<5 RE). Based on the angle between the flow and the magnetic field, the high-speed flow events are further divided into two types, that is,field-aligned high-speed flow (FAHF) in the plasma sheet boundary and convective bursty bulk flow (BBF) in the center plasma sheet. Among the total 465 high-speed flow events, there are 371 FAHFs,and 94 BBFs. The CHF are mainly concentrated in the plasma sheet, the intersection angle between the flow and the magnetic field is larger, the magnetic field intensity is relatively weak. The FHF are mainly distributed near the boundary layer of the plasma sheet, the intersection angle between the flow and magnetic field is smaller, and the magnetic field intensity is relatively strong. The convective BBFs have an important effect on the substorm.

  3. Computational analysis of high-throughput flow cytometry data

    Science.gov (United States)

    Robinson, J Paul; Rajwa, Bartek; Patsekin, Valery; Davisson, Vincent Jo

    2015-01-01

    Introduction Flow cytometry has been around for over 40 years, but only recently has the opportunity arisen to move into the high-throughput domain. The technology is now available and is highly competitive with imaging tools under the right conditions. Flow cytometry has, however, been a technology that has focused on its unique ability to study single cells and appropriate analytical tools are readily available to handle this traditional role of the technology. Areas covered Expansion of flow cytometry to a high-throughput (HT) and high-content technology requires both advances in hardware and analytical tools. The historical perspective of flow cytometry operation as well as how the field has changed and what the key changes have been discussed. The authors provide a background and compelling arguments for moving toward HT flow, where there are many innovative opportunities. With alternative approaches now available for flow cytometry, there will be a considerable number of new applications. These opportunities show strong capability for drug screening and functional studies with cells in suspension. Expert opinion There is no doubt that HT flow is a rich technology awaiting acceptance by the pharmaceutical community. It can provide a powerful phenotypic analytical toolset that has the capacity to change many current approaches to HT screening. The previous restrictions on the technology, based on its reduced capacity for sample throughput, are no longer a major issue. Overcoming this barrier has transformed a mature technology into one that can focus on systems biology questions not previously considered possible. PMID:22708834

  4. 3-Dimensional numerical study of cooling performance of a heat sink with air-water flow through mini-channel

    Science.gov (United States)

    Majumder, Sambit; Majumder, Abhik; Bhaumik, Swapan

    2016-07-01

    The present microelectronics market demands devices with high power dissipation capabilities having enhanced cooling per unit area. The drive for miniaturizing the devices to even micro level dimensions is shooting up the applied heat flux on such devices, resulting in complexity in heat transfer and cooling management. In this paper, a method of CPU processor cooling is introduced where active and passive cooling techniques are incorporated simultaneously. A heat sink consisting of fins is designed, where water flows internally through the mini-channel fins and air flows externally. Three dimensional numerical simulations are performed for large set of Reynolds number in laminar region using finite volume method for both developing flows. The dimensions of mini-channel fins are varied for several aspect ratios such as 1, 1.33, 2 and 4. Constant temperature (T) boundary condition is applied at heat sink base. Channel fluid temperature, pressure drop are analyzed to obtain best cooling option in the present study. It has been observed that as the aspect ratio of the channel decreases Nusselt number decreases while pressure drop increases. However, Nusselt number increases with increase in Reynolds number.

  5. Premixed CH4-Air Flame Structure Characteristic and Flow Behavior Induced by Obstacle in an Open Duct

    Directory of Open Access Journals (Sweden)

    DengKe Li

    2015-01-01

    Full Text Available To study the fuel gas combustion hazards, the methane/air flame structure and flow characteristic in an open duct influenced by a rectangular obstacle were explored by experiment and realizable k-∊ model (RKE. In the test, the high-speed schlieren photography technology and dynamic detection technology were applied to record the flame propagation behavior. Meanwhile, the interaction between flame front and flame flow field induced by the obstacle was disclosed. In addition, the laminar-turbulence transition was also taken into consideration. The RKE and eddy dissipation concept (EDC premixed combustion model were applied to obtain an insight into the phenomenon of flow change and wrinkle appearing, which potently explained the experimental observations. As a result, the obstacle blocked the laminar flame propagation velocity and increased pressure a little in an open duct. Some small-scale vortices began to appear near the obstacle, mainly due to Kelvin-Helmholtz instability (KHI, and gradually grew into large-scale vortices, which led to laminar-turbulent transition directly. The vortices thickened the reaction area and hastened the reaction rate; reversely, the higher reaction rate induced larger vortices. The RKE model result fitted the test data well and explained the wrinkle forming mechanism of two special vortices in the case.

  6. Numerical simulations of high Knudsen number gas flows and microchannel electrokinetic liquid flows

    Science.gov (United States)

    Yan, Fang

    Low pressure and microchannel gas flows are characterized by high Knudsen numbers. Liquid flows in microchannels are characterized by non-conventional driving potentials like electrokinetic forces. The main thrust of the dissertation is to investigate these two different kinds of flows in gases and liquids respectively. High Knudsen number (Kn) gas flows were characterized by 'rarified' or 'microscale' behavior. Because of significant non-continuum effect, traditional CFD techniques are often inaccurate for analyzing high Kn number gas flows. The direct simulation Monte Carlo (DSMC) method offers an alternative to traditional CFD which retains its validity in slip and transition flow regimes. To validate the DSMC code, comparisons of simulation results with theoretical analysis and experimental data are made. The DSMC method was first applied to compute low pressure, high Kn flow fields in partially heated two dimensional channels. The effects of varying pressure, inlet flow and gas transport properties (Kn, Reynolds number, Re and the Prandtl number, Pr respectively) on the wall heat transfer (Nusselt number, Nu) were examined. The DSMC method was employed to explore mixing gas flows in two dimensional microchannels. Mixing of two gas streams (H2 and O2) was considered within a microchannel. The effect of the inlet-outlet pressure difference, the pressure ratio of the incoming streams and the accommodation coefficient of the solid wall on mixing length were all examined. Parallelization of a three-dimensional DSMC code was implemented using OpenMP procedure on a shared memory multi-processor computer. The parallel code was used to simulate 3D high Kn number Couette flow and the flow characteristics are found to be very different from their continuum counterparts. A mathematical model describing electrokinetically driven mass transport phenomena in microfabricated chip devices will also be presented. The model accounts for the principal physical phenomena affecting

  7. Multitechnique characterisation of 304L surface states oxidised at high temperature in steam and air atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Mamede, Anne-Sophie, E-mail: anne-sophie.mamede@ensc-lille.fr [University Lille, CNRS, ENSCL, Centrale Lille, University Artois, UMR 8181 – UCCS – Unité de Catalyse et Chimie du Solide, F-59000 Lille (France); Nuns, Nicolas, E-mail: nicolas.nuns@univ-lille1.fr [University Lille, CNRS, ENSCL, Centrale Lille, University Artois, UMR 8181 – UCCS – Unité de Catalyse et Chimie du Solide, F-59000 Lille (France); Cristol, Anne-Lise, E-mail: anne-lise.cristol@ec-lille.fr [University Lille, CNRS, Centrale Lille, Arts et Métiers Paris Tech, FRE 3723 – LML – Laboratoire de Mécanique de Lille, F-59000 Lille (France); Cantrel, Laurent, E-mail: laurent.cantrel@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire, PSN-RES, Cadarache, Saint Paul lez Durance, 13115 (France); Laboratoire de Recherche Commun IRSN-CNRS-Lille 1: «Cinétique Chimique, Combustion, Réactivité» (C3R), Cadarache, Saint Paul lez Durance, 13115 (France); Souvi, Sidi, E-mail: sidi.souvi@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire, PSN-RES, Cadarache, Saint Paul lez Durance, 13115 (France); Laboratoire de Recherche Commun IRSN-CNRS-Lille 1: «Cinétique Chimique, Combustion, Réactivité» (C3R), Cadarache, Saint Paul lez Durance, 13115 (France); and others

    2016-04-30

    Graphical abstract: - Highlights: • Mutitechnique characterisation of oxidised 304L. • Oxidation at high temperature under steam and air conditions of 304L stainless steel. • Chromium and manganese oxides formed in the outer layer. • Oxide profiles differ in air or steam atmosphere. - Abstract: In case of a severe accident occurring in a nuclear reactor, surfaces of the reactor coolant system (RCS), made of stainless steel (304L) rich in Cr (>10%) and Ni (8–12%), are oxidised. Fission products (FPs) are released from melt fuel and flow through the RCS. A part of them is deposited onto surfaces either by vapour condensation or by aerosol deposition mechanisms. To be able to understand the nature of interactions between these FPs and the RCS surfaces, a preliminary step is to characterize the RSC surface states in steam and air atmosphere at high temperatures. Pieces of 304L stainless steel have been treated in a flow reactor at two different temperatures (750 °C and 950 °C) for two different exposition times (24 h and 72 h). After surfaces analysing by a unique combination of surface analysis techniques (XPS, ToF-SIMS and LEIS), for 304L, the results show a deep oxide scale with multi layers and the outer layer is composed of chromium and manganese oxides. Oxide profiles differ in air or steam atmosphere. Fe{sub 2}O{sub 3} oxide is observed but in minor proportion and in all cases no nickel is detected near the surface. Results obtained are discussed and compared with the literature data.

  8. High-Throughput Continuous Flow Production of Nanoscale Liposomes by Microfluidic Vertical Flow Focusing.

    Science.gov (United States)

    Hood, Renee R; DeVoe, Don L

    2015-11-18

    Liposomes represent a leading class of nanoparticles for drug delivery. While a variety of techniques for liposome synthesis have been reported that take advantage of microfluidic flow elements to achieve precise control over the size and polydispersity of nanoscale liposomes, with important implications for nanomedicine applications, these methods suffer from extremely limited throughput, making them impractical for large-scale nanoparticle synthesis. High aspect ratio microfluidic vertical flow focusing is investigated here as a new approach to overcoming the throughput limits of established microfluidic nanoparticle synthesis techniques. Here the vertical flow focusing technique is utilized to generate populations of small, unilamellar, and nearly monodisperse liposomal nanoparticles with exceptionally high production rates and remarkable sample homogeneity. By leveraging this platform, liposomes with modal diameters ranging from 80 to 200 nm are prepared at production rates as high as 1.6 mg min(-1) in a simple flow-through process.

  9. High Resolution Continuous Flow Analysis System for Polar Ice Cores

    Science.gov (United States)

    Dallmayr, Remi; Azuma, Kumiko; Yamada, Hironobu; Kjær, Helle Astrid; Vallelonga, Paul; Azuma, Nobuhiko; Takata, Morimasa

    2014-05-01

    In the last decades, Continuous Flow Analysis (CFA) technology for ice core analyses has been developed to reconstruct the past changes of the climate system 1), 2). Compared with traditional analyses of discrete samples, a CFA system offers much faster and higher depth resolution analyses. It also generates a decontaminated sample stream without time-consuming sample processing procedure by using the inner area of an ice-core sample.. The CFA system that we have been developing is currently able to continuously measure stable water isotopes 3) and electrolytic conductivity, as well as to collect discrete samples for the both inner and outer areas with variable depth resolutions. Chemistry analyses4) and methane-gas analysis 5) are planned to be added using the continuous water stream system 5). In order to optimize the resolution of the current system with minimal sample volumes necessary for different analyses, our CFA system typically melts an ice core at 1.6 cm/min. Instead of using a wire position encoder with typical 1mm positioning resolution 6), we decided to use a high-accuracy CCD Laser displacement sensor (LKG-G505, Keyence). At the 1.6 cm/min melt rate, the positioning resolution was increased to 0.27mm. Also, the mixing volume that occurs in our open split debubbler is regulated using its weight. The overflow pumping rate is smoothly PID controlled to maintain the weight as low as possible, while keeping a safety buffer of water to avoid air bubbles downstream. To evaluate the system's depth-resolution, we will present the preliminary data of electrolytic conductivity obtained by melting 12 bags of the North Greenland Eemian Ice Drilling (NEEM) ice core. The samples correspond to different climate intervals (Greenland Stadial 21, 22, Greenland Stadial 5, Greenland Interstadial 5, Greenland Interstadial 7, Greenland Stadial 8). We will present results for the Greenland Stadial -8, whose depths and ages are between 1723.7 and 1724.8 meters, and 35.520 to

  10. Root-soil air gap and resistance to water flow at the soil-root interface of Robinia pseudoacacia.

    Science.gov (United States)

    Liu, X P; Zhang, W J; Wang, X Y; Cai, Y J; Chang, J G

    2015-12-01

    During periods of water deficit, growing roots may shrink, retaining only partial contact with the soil. In this study, known mathematical models were used to calculate the root-soil air gap and water flow resistance at the soil-root interface, respectively, of Robinia pseudoacacia L. under different water conditions. Using a digital camera, the root-soil air gap of R. pseudoacacia was investigated in a root growth chamber; this root-soil air gap and the model-inferred water flow resistance at the soil-root interface were compared with predictions based on a separate outdoor experiment. The results indicated progressively greater root shrinkage and loss of root-soil contact with decreasing soil water potential. The average widths of the root-soil air gap for R. pseudoacacia in open fields and in the root growth chamber were 0.24 and 0.39 mm, respectively. The resistance to water flow at the soil-root interface in both environments increased with decreasing soil water potential. Stepwise regression analysis demonstrated that soil water potential and soil temperature were the best predictors of variation in the root-soil air gap. A combination of soil water potential, soil temperature, root-air water potential difference and soil-root water potential difference best predicted the resistance to water flow at the soil-root interface.

  11. Prediction and Control of Air Flow in Acid-Generating Waste Rock Dumps

    Science.gov (United States)

    Wels, C.; Lefebvre, R.; Robertson, A. M.

    2004-05-01

    Air movement and associated oxygen transport through waste rock dumps has the potential to significantly enhance the rate of oxidation of pyrite-bearing material. While this is a desired outcome for most heap leach operations, airflow in waste rock storage facilities can result in significant increases in generation and acceleration of acid rock drainage. Hence, a good understanding of internal airflow through waste rock dumps is required to control ARD and minimize any associated liability. The principal mechanisms contributing to airflow and oxygen transport in a waste rock pile include (i) diffusion, (ii) advection due to a thermal gradient (chimney effect) and/or wind pressure gradients and (iii) advection due to barometric pumping. While diffusion is typically limited to a near-surface zone of a few meters depth, advection and barometric pumping have the potential to move air (and oxygen) to much greater depths into the pile. In general, the more permeable the waste rock material, and the greater the height-to-width ratio of the waste rock pile, the greater is the potential for advective air movement. The reactivity of the waste rock material as well as the coarseness (hence air permeability), and the spatial variability of these properties within a pile, have a strong influence on the magnitude of thermally induced advection. In contrast, air movement due to barometric pumping is controlled by the waste rock porosity, changes in ambient air pressure and the heterogeneity of air permeability of the waste rock dump. Results of field monitoring and numerical modeling using TOUGH AMD are presented to illustrate the concepts on air movement in waste rock piles. During the design and construction phase, airflow can be controlled by judicious placement of reactive waste rock and use of selective placement techniques to control the internal structure of the waste rock facility (e.g. introduction of horizontal layering, prevention of inclined, high

  12. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

    Science.gov (United States)

    Battista, L.; Sciuto, S. A.; Scorza, A.

    2013-03-01

    In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 × 10-4 m3/s (18.0 l/min) for the mono-directional sensor and a measurement range of ±3.00 × 10-4 m3/s (±18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the

  13. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique.

    Science.gov (United States)

    Battista, L; Sciuto, S A; Scorza, A

    2013-03-01

    In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 × 10(-4) m(3)∕s (18.0 l∕min) for the mono-directional sensor and a measurement range of ±3.00 × 10(-4) m(3)∕s (±18.0 l∕min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono

  14. Identify temporal trend of air temperature and its impact on forest stream flow in Lower Mississippi River Alluvial Valley using wavelet analysis

    Science.gov (United States)

    Ying Ouyang; Prem B. Parajuli; Yide Li; Theodor D. Leininger; Gary Feng

    2017-01-01

    Characterization of stream flow is essential to water resource management, water supply planning, environmental protection, and ecological restoration; while air temperature variation due to climate change can exacerbate stream flow and add instability to the flow. In this study, the wavelet analysis technique was employed to identify temporal trend of air temperature...

  15. Transient analysis of counterflowing jet over highly blunt cone in hypersonic flow

    Science.gov (United States)

    Barzegar Gerdroodbary, M.; Bishehsari, Shervin; Hosseinalipour, S. M.; Sedighi, K.

    2012-04-01

    Understanding the characteristics of various Counterflowing jets exiting from a nose cone is crucial for determining heat load reduction and usage of this device in various conditions. Such jets can undergo several flow regimes during venting, from initial supersonic flow, to transonic, to subsonic flow regimes as the pressure of jet decreases. A bow shock wave is a characteristic flow structure during the initial stage of the jet development, and this paper focuses on the development of the bow shock wave and the jet structure behind it. The transient behavior of a sonic counterflow jet is investigated using unsteady, axisymmetric Navier-Stokes solved with SST turbulence model at free stream Mach number of 5.75. The coolant gas (Carbon Dioxide and Helium) is chosen to inject into the hypersonic air flow at the nose of the model. The gases are considered to be ideal, and the computational domain is axisymmetric. The jet structure, including the shock wave and flow separation due to an adverse pressure gradient at the nose is investigated with a focus on the differences between high diffusivity coolant jet (Helium) and low diffusivity coolant jet (CO2) flow scenarios.

  16. Effect of attack and cone angels on air flow characteristics for staggered wing shaped tubes bundle

    Science.gov (United States)

    Sayed Ahmed, Sayed E.; Ibrahiem, Emad Z.; Mesalhy, Osama M.; Abdelatief, Mohamed A.

    2014-12-01

    An experimental and numerical study has been conducted to clarify fluid flow characteristics and pressure drop distributions of a cross-flow heat exchanger employing staggered wing-shaped tubes at different angels of attack. The water-side Rew and the air-side Rea were at 5 × 102 and at from 1.8 × 103 to 9.7 × 103, respectively. Three cases of the tubes arrangements with various angles of attack, row angles of attack and 90° cone angles were employed at the considered Rea range. Correlation of pressure drop coefficient Pdc in terms of Rea, design parameters for the studied cases were presented. The flow pattern around the staggered wing-shaped tubes bundle were predicted using the commercial CFD FLUENT 6.3.26 software package. Results indicated that the values of Pdc increased with the angle of attack from 0° to 45°, while the opposite was true for angles of attack from 135° to 180°. The values of Pdc for the arrangements of (θ1,2,3 = 45°), (θ1 = 45°, θ2 = 0°, θ3 = 45°), and (θ1,2,3 = 0°) were lower than those for the arrangement of (ϕ1 = ϕ2 = ϕ3 = 90°) by about 33, 53, and 91 %, respectively. Comparisons between the experimental and numerical results of the present study and those obtained by similar previous studies showed good agreements.

  17. NUMERICAL SIMULATION OF THE AIR FLOW AROUND THE ARRAYS OF SOLAR COLLECTORS

    Directory of Open Access Journals (Sweden)

    Vukman V Bakić

    2011-01-01

    Full Text Available This paper deals with the numerical simulation of air around the arrays of flat plate collectors and determination of the flow field, which should provide a basis for estimating a convective heat losses, a parameter which influences their working characteristics. Heat losses are the result of the reflection on the glass, conductive losses at the collector's absorber plate, radiation of the absorber plate and convective losses on the glass. Wind velocity in the vicinity of the absorber plate depends on its position in the arrays of collectors. Results obtained in the numerical simulation of flow around collectors were used as boundary conditions in modeling of thermal-hydraulic processes inside the solar collector. A method for coupling thermal-hydraulic processes inside the collector with heat transfer from plate to tube bundle was developed, in order to find out the distribution of the temperature of the absorber plate and the efficiency of the flat plate collectors. Analyses of flow around arrays of collectors are preformed with RNG k - ε model. Three values for free-stream velocity were analysed, i.e. 1 m/s, 5 m/s and 10 m/s, as well as two values for the angle between the ground and the collector (20° and 40°. Heat transfer coefficient was determined from the theory of boundary layer. Heat transfer inside the plate cavity was analyzed assuming constant intensity of radiation.

  18. Validation of Three-Dimensional Simulation of Flow through Hypersonic Air-breathing Engine

    Directory of Open Access Journals (Sweden)

    Thangadurai Murugan

    2015-07-01

    Full Text Available The flow path of a conceptual hypersonic air-breathing scramjet engine integrated with the vehicle (without combustion has been simulated numerically using ANSYS CFX software with the SST turbulence model. The computations were performed for the free stream Mach number of 6 and angle-of-attack of 5°. A strong separation bubble was observed on the bodyside wall in the internal compression region where the reflected cowl shock impinges on body which in turn increases the static pressure substantially. The external-internal flow field of the hypersonic mixed compression intake, shock-boundary layer interactions, and the shock-shock interactions present in the internal compression region have qualitatively been obtained and analysed. The variation of centreline pressure along the bodyside wall close to the symmetry plane obtained from numerical simulation centreline has been compared with the experimentally measured data. It has been observed that the computed wall pressure matches fairly well with the measured values in the external ramp compression region, internal compression region and in the combustion chamber. The flow patterns and the pressure variations near the middle wall and the fuel injecting strut locations have also been analysed.Defence Science Journal, Vol. 65, No. 4, July 2015, pp. 272-278, DOI: http://dx.doi.org/10.14429/dsj.65.6979

  19. High-efficiency design of a mixed-flow pump

    Institute of Scientific and Technical Information of China (English)

    KIM; Jin-Hyuk; AHN; Hyung-Jin; KIM; Kwang-Yong

    2010-01-01

    High-efficiency design of a mixed-flow pump has been carried out based on numerical analysis of a three-dimensional viscous flow.For analysis,the Reynolds-averaged Navier-Stokes equations with a shear stress transport turbulence model were discretized by finite-volume approximations.Structured grid system was constructed in the computational domain,which has O-type grids near the blade surfaces and H/J-type grids in other regions.The numerical results were validated with experimental data for the heads and hydraulic efficiencies at different flow coefficients.The hydraulic efficiency at the design flow coefficient was evaluated with variation of the geometric variables,i.e.,the area of the discharge and length of the vane in the diffuser.The result has shown that the hydraulic efficiency of a mixed-flow pump at the design condition is improved by the modification of the geometry.

  20. Deployable Emergency Shutoff Device Blocks High-Velocity Fluid Flows

    Science.gov (United States)

    Nabors, Sammy A.

    2015-01-01

    NASA's Marshall Space Flight Center has developed a device and method for blocking the flow of fluid from an open pipe. Motivated by the sea-bed oil-drilling catastrophe in the Gulf of Mexico in 2010, NASA innovators designed the device to plug, control, and meter the flow of gases and liquids. Anchored with friction fittings, spikes, or explosively activated fasteners, the device is well-suited for harsh environments and high fluid velocities and pressures. With the addition of instrumentation, it can also be used as a variable area flow metering valve that can be set based upon flow conditions. With robotic additions, this patent-pending innovation can be configured to crawl into a pipe then anchor and activate itself to block or control fluid flow.

  1. Air flow-assisted ionization imaging mass spectrometry method for easy whole-body molecular imaging under ambient conditions.

    Science.gov (United States)

    Luo, Zhigang; He, Jiuming; Chen, Yi; He, Jingjing; Gong, Tao; Tang, Fei; Wang, Xiaohao; Zhang, Ruiping; Huang, Lan; Zhang, Lianfeng; Lv, Haining; Ma, Shuanggang; Fu, Zhaodi; Chen, Xiaoguang; Yu, Shishan; Abliz, Zeper

    2013-03-01

    Whole-body molecular imaging is able to directly map spatial distribution of molecules and monitor its biotransformation in intact biological tissue sections. Imaging mass spectrometry (IMS), a label-free molecular imaging method, can be used to image multiple molecules in a single measurement with high specificity. Herein, a novel easy-to-implement, whole-body IMS method was developed with air flow-assisted ionization in a desorption electrospray ionization mode. The developed IMS method can effectively image molecules in a large whole-body section in open air without sample pretreatment, such as chemical labeling, section division, or matrix deposition. Moreover, the signal levels were improved, and the spatial assignment errors were eliminated; thus, high-quality whole-body images were obtained. With this novel IMS method, in situ mapping analysis of molecules was performed in adult rat sections with picomolar sensitivity under ambient conditions, and the dynamic information of molecule distribution and its biotransformation was provided to uncover molecular events at the whole-animal level. A global view of the differential distribution of an anticancer agent and its metabolites was simultaneously acquired in whole-body rat and model mouse bearing neuroglioma along the administration time. The obtained drug distribution provided rich information for identifying the targeted organs and predicting possible tumor spectrum, pharmacological activity, and potential toxicity of drug candidates.

  2. Secondary Organic Aerosol Formation from Ambient Air in an Oxidation Flow Reactor at GoAmazon2014/5

    Science.gov (United States)

    Palm, Brett B.; de Sa, Suzane S.; Campuzano-Jost, Pedro; Day, Douglas A.; Hu, Weiwei; Seco, Roger; Park, Jeong-Hoo; Guenther, Alex; Kim, Saewung; Brito, Joel; Wurm, Florian; Artaxo, Paulo; Yee, Lindsay; Isaacman-VanWertz, Gabrial; Goldstein, Allen; Newburn, Matt K.; Lizabeth Alexander, M.; Martin, Scot T.; Brune, William H.; Jimenez, Jose L.

    2016-04-01

    During GoAmazon2014/5, ambient air was exposed to controlled concentrations of OH or O3 in situ using an oxidation flow reactor (OFR). Oxidation ranged from hours-several weeks of aging. Oxidized air was sampled by several instruments (e.g., HR-AMS, ACSM, PTR-TOF-MS, SMPS, CCN) at both the T3 site (IOP1: Feb 1-Mar 31, 2014, and IOP2: Aug 15-Oct 15, 2014) and T2 site (between IOPs and into 2nd IOP). The oxidation of ambient air in the OFR led to substantial and variable secondary organic aerosol (SOA) formation from any SOA-precursor gases, known and unknown, that entered the OFR. In general, more SOA was produced during the nighttime than daytime, suggesting that SOA-precursor gases were found in relatively higher concentrations at night. Similarly, more SOA was formed in the dry season (IOP2) than wet season (IOP1). The maximum amount of SOA produced during nighttime from OH oxidation ranged from less than 1 μg/m3 on some nights to greater than 10 μg/m3 on other nights. O3 oxidation of ambient air also led to SOA formation, although several times less than from OH oxidation. The amount of SOA formation sometimes, but not always, correlated with measured gas-phase biogenic and/or anthropogenic SOA precursors (e.g., SV-TAG sesquiterpenes, PTR-TOFMS aromatics, isoprene, and monoterpenes). The SOA mass formed in the OFR from OH oxidation was up to an order of magnitude larger than could be explained from aerosol yields of measured primary VOCs. This along with measurements from previous campaigns suggests that most SOA was formed from intermediate S/IVOC sources (e.g., VOC oxidation products, evaporated POA, or direct emissions). To verify the SOA yields of VOCs under OFR experimental conditions, atmospherically-relevant concentrations of several VOCs were added individually into ambient air in the OFR and oxidized by OH or O3. SOA yields in the OFR were similar to published chamber yields. Preliminary PMF factor analysis showed production of secondary factors in

  3. Quartz measurement in coal dust with high-flow rate samplers: laboratory study.

    Science.gov (United States)

    Lee, Taekhee; Lee, Eun Gyung; Kim, Seung Won; Chisholm, William P; Kashon, Michael; Harper, Martin

    2012-05-01

    A laboratory study was performed to measure quartz in coal dust using high-flow rate samplers (CIP10-R, GK2.69 cyclone, and FSP10 cyclone) and low-flow rate samplers [10-mm nylon and Higgins-Dewell type (BGI4L) cyclones] and to determine whether an increased mass collection from high-flow rate samplers would affect the subsequent quartz measurement by Fourier transform infrared (FTIR) and X-ray diffraction (XRD) analytical procedures. Two different sizes of coal dusts, mass median aerodynamic diameter 4.48 μm (Coal Dust A) and 2.33 μm (Coal Dust B), were aerosolized in a calm air chamber. The mass of coal dust collected by the samplers was measured gravimetrically, while the mass of quartz collected by the samplers was determined by FTIR (NIOSH Manual of Analytical Method 7603) and XRD (NIOSH Manual of Analytical Method 7500) after one of two different indirect preparations. Comparisons between high-flow rate samplers and low-flow rate samplers were made by calculating mass concentration ratios of coal dusts, net mass ratios of coal dusts, and quartz net mass. Mass concentrations of coal dust from the FSP10 cyclone were significantly higher than those from other samplers and mass concentrations of coal dust from 10-mm nylon cyclone were significantly lower than those from other samplers, while the CIP10-R, GK2.69, and BGI4L samplers did not show significant difference in the comparison of mass concentration of coal dusts. The BGI4L cyclone showed larger mass concentration of ∼9% compared to the 10-mm nylon cyclone. All cyclones provided dust mass concentrations that can be used in complying with the International Standard Organization standard for the determination of respirable dust concentration. The amount of coal dust collected from the high-flow rate samplers was found to be higher with a factor of 2-8 compared to the low-flow rate samplers but not in direct proportion of increased flow rates. The high-flow rate samplers collected more quartz compared to

  4. Evaluation of the performance of the cross-flow air classifier in manufactured sand processing via CFD-DEM simulations

    Science.gov (United States)

    Petit, H. A.; Irassar, E. F.; Barbosa, M. R.

    2017-03-01

    Manufactured sands are particulate materials obtained as by product of rock crushing. Particle sizes in the sand can be as high as 6 mm and as low as a few microns. The concrete industry has been increasingly using these sands as fine aggregates to replace natural sands. The main shortcoming is the excess of particles smaller than element modelling (DEM) were used for the assessment. Results show that the correct classification set up improves the size distribution of the raw materials. The cross-flow air classification is found to be influenced by the particle size distribution and the turbulence inside the chamber. The classifier can be re-designed to work at low inlet velocities to produce manufactured sand for the concrete industry.

  5. Numerical simulation of high speed chemically reacting flows

    Science.gov (United States)

    Schuricht, Scott Richard

    A single step second-order accurate flux-difference-splitting method has been developed for solving unsteady quasi-one-dimensional and two-dimensional flows of multispecies fluids with finite rate chemistry. A systematic method for incorporating the source term effects into the wave strength parameters of Roe's linearized approximate Riemann solver is presented that is consistent with characteristic theory. The point implicit technique is utilized to achieve second-order time accuracy of the local area source term The stiffness associated with the chemical reactions is removed by implicitly integrating the kinetics system using the LSODE package. From the implicit integration, values of the species production rates are developed and incorporated into the flux-difference-splitting framework using a source term projection and splitting technique that preserves the upwind nature of source terms. Numerous validation studies are presented to illustrate the capability of the numerical method. Shock tube and converging-diverging nozzle cases show the method is second order accurate in space and time for one-dimensional flows. A supersonic source flow case and a subsonic sink flow case show the method is second order spatially accurate for two-dimensional flows. Static combustion and steady supersonic combustion cases illustrate the ability of the method to accurately capture the ignition delay for hydrogen-air mixtures. Demonstration studies are presented to illustrate the capabilities of the method. One-dimensional flow in a shock tube predicts species dissociation behind the main shock wave. One-dimension flow in supersonic nozzles predicts the well-known chemical freezing effect in an expanding flow. Two-dimensional cases consisted of a model of a scramjet combustor and a rocket motor nozzle. A parametric study was performed on a model of a scramjet combustor. The parameters studied were; wall angle, inlet Mach number, inlet temperature, and inlet equivalence ratio

  6. High pressure axial flow fans for modern coal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Cyrus, Vaclav [AHT Energetika s.r.o., Praha (Czech Republic); Koci, Petr [ZVVZ Milevsko a.s. (Czech Republic)

    2008-07-01

    Brown coal fired power stations, located in Northern Bohemia, have mostly older boiler blocks with an output of 110 and 200 MWe. Flue gases are cleaned by the desulphurization plants installed between 1993 and 1997. Usually, each boiler block has two air fans and one to three flue gas fans. Flue gas fans operate in severe conditions; fan blades should be resistant to the flue gases containing sulphur and acid drops with the operating temperature at 170 C to 190 C. Additionally, flue gas also often contains ash particles. Currently, some boiler blocks are gradually being refurbished. New blocks with an electrical power output of 600 to 700 MWe are at the design stage. Submitted paper shows our design study of one stage axial flow fan for the new blocks. Results from the new aerodynamic research of the axial flow stages were used in the fan design. (orig.)

  7. Turbulent behaviour of non-cohesive sediment gravity flows at unexpectedly high flow density

    Science.gov (United States)

    Baker, Megan; Baas, Jaco H.; Malarkey, Jonathan; Kane, Ian

    2016-04-01

    Experimental lock exchange-type turbidity currents laden with non-cohesive silica-flour were found to be highly dynamic at remarkably high suspended sediment concentrations. These experiments were conducted to produce sediment gravity flows of volumetric concentrations ranging from 1% to 52%, to study how changes in suspended sediment concentration affects the head velocities and run-out distances of these flows, in natural seawater. Increasing the volumetric concentration of suspended silica-flour, C, up to C = 46%, within the flows led to a progressive increase in the maximum head velocity. This relationship suggests that suspended sediment concentration intensifies the density difference between the turbulent suspension and the ambient water, which drives the flow, even if almost half of the available space is occupied by sediment particles. However, from C = 46% to C = 52% a rapid reduction in the maximum head velocity was measured. It is inferred that at C = 46%, friction from grain-to-grain interactions begins to attenuate turbulence within the flows. At C > 46%, the frictional stresses become progressively more dominant over the turbulent forces and excess density, thus producing lower maximum head velocities. This grain interaction process started to rapidly reduce the run-out distance of the silica-flour flows at equally high concentrations of C ≥ 47%. All flows with C 9%. Yet, the critical flow concentration at which turbulence modulation commenced for these silica-flour laden flows appeared to be much higher. We suggest that Bagnold's 9% criterion cannot be applied to flows that carry fine-grained sediment, because turbulent forces are more important than dispersive forces, and frictional forces start to affect the flows only at concentrations just below the cubic packing density of spheres of C = 52%. These experimental results also imply that natural flows may be able to transport vast volumes of non-cohesive sediment with relative ease, especially

  8. A simple analytical method to estimate all exit parameters of a cross-flow air dehumidifier using liquid desiccant.

    Science.gov (United States)

    Bassuoni, M M

    2014-03-01

    The dehumidifier is a key component in liquid desiccant air-conditioning systems. Analytical solutions have more advantages than numerical solutions in studying the dehumidifier performance parameters. This paper presents the performance results of exit parameters from an analytical model of an adiabatic cross-flow liquid desiccant air dehumidifier. Calcium chloride is used as desiccant material in this investigation. A program performing the analytical solution is developed using the engineering equation solver software. Good accuracy has been found between analytical solution and reliable experimental results with a maximum deviation of +6.63% and -5.65% in the moisture removal rate. The method developed here can be used in the quick prediction of the dehumidifier performance. The exit parameters from the dehumidifier are evaluated under the effects of variables such as air temperature and humidity, desiccant temperature and concentration, and air to desiccant flow rates. The results show that hot humid air and desiccant concentration have the greatest impact on the performance of the dehumidifier. The moisture removal rate is decreased with increasing both air inlet temperature and desiccant temperature while increases with increasing air to solution mass ratio, inlet desiccant concentration, and inlet air humidity ratio.

  9. Creep behavior of alloy 617 in high temperature air and helium environments-effect of oxidation damage

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Chang Heui; Kim, Sung Hwan [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Sah, Injin; Kim, Dae Jong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The creep behavior of a nickel-base superalloy, Alloy 617, which is considered as a candidate material for the very high temperature gas cooled reactor, was studied. Creep rupture tests were carried out at 800°C, 900°C and 1000°C in static and flowing helium environments as well as in air. Creep rupture life in static helium was longer than that in air, while it was shorter in flowing helium environments. Microstructure observation of the creep tested specimens showed that the shorter creep rupture life in flowing helium was associated with the thicker oxide layer, greater decarburization depth, and deeper internal oxidation happened during the creep tests. The degree of such oxidation damage was quantified for the creep tested specimens and correlated with the creep rupture life in different environments.

  10. Efficient algorithms for optimal arrival scheduling and air traffic flow management

    Science.gov (United States)

    Saraf, Aditya

    The research presented in this dissertation is motivated by the need for new, efficient algorithms for the solution of two important problems currently faced by the air-traffic control community: (i) optimal scheduling of aircraft arrivals at congested airports, and (ii) optimal National Airspace System (NAS) wide traffic flow management. In the first part of this dissertation, we present an optimal airport arrival scheduling algorithm, which works within a hierarchical scheduling structure. This structure consists of schedulers at multiple points along the arrival-route. Schedulers are linked through acceptance-rate constraints, which are passed up from downstream metering-points. The innovation in this scheduling algorithm is that these constraints are computed by using an Eulerian model-based optimization scheme. This rate computation removes inefficiencies introduced in the schedule through ad hoc acceptance-rate computations. The scheduling process at every metering-point uses its optimal acceptance-rate as a constraint and computes optimal arrival sequences by using a combinatorial search-algorithm. We test this algorithm in a dynamic air-traffic environment, which can be customized to emulate different arrival scenarios. In the second part of this dissertation, we introduce a novel two-level control system for optimal traffic-flow management. The outer-level control module of this two-level control system generates an Eulerian-model of the NAS by aggregating aircraft into interconnected control-volumes. Using this Eulerian model of the airspace, control strategies like Model Predictive Control are applied to find the optimal inflow and outflow commands for each control-volume so that efficient flows are achieved in the NAS. Each control-volume has its separate inner-level control-module. The inner-level control-module takes in the optimal inflow and outflow commands generated by the outer control-module as reference inputs and uses hybrid aircraft models to

  11. Simulating High Reynolds Number Flow by Lattice Boltzmann Method

    Institute of Scientific and Technical Information of China (English)

    KANG Xiu-Ying; LIU Da-He; ZHOU Jing; JIN Yong-Juan

    2005-01-01

    @@ A two-dimensional channel flow with different Reynolds numbers is tested by using the lattice Boltzmann method under different pressure and velocity boundary conditions. The results show that the simulation error increases,and the pressure and the flow rate become unstable under a high Reynolds number. To improve the simulation precision under a high Reynolds number, the number of fluid nodes should be enlarged. For a higher Reynoldsnumber flow, the velocity boundary with an approximately parabolic velocity profile is found to be more adaptive.Blood flow in an artery with cosine shape symmetrical narrowing is then simulated under a velocity boundary condition. Its velocity, pressure and wall shear stress distributions are consistent with previous studies.

  12. Carbon film deposition from high velocity rarefied flow

    Energy Technology Data Exchange (ETDEWEB)

    Rebrov, A.K., E-mail: rebrov@itp.nsc.ru; Emelyanov, A.A.; Yudin, I.B.

    2015-01-30

    The presented study is based on the idea of the activation of a gas-precursor high velocity flow by hot wire. The wire forms the channel for flow before expansion to substrate. The construction allows change of the specific flow rate, velocity, composition and temperature of a gas mixture by studying the film synthesis in conditions from free molecular to continuum flow at velocities from hundreds to thousands of m/s. At a high pressure, the film has typical and unusual hexagonal incorporations for diamond tetragonal particles. Raman spectrum with the pronounced diamond peak is typical for diamond-like film. X-ray diffraction points in the presence of lonsdaleite. Conditions of deposition were simulated by Monte Carlo method. Collisions with hot surfaces and chemical transformations were taken into consideration as well.

  13. Thermodynamic diagrams for high temperature plasmas of air, air-carbon, carbon-hydrogen mixtures, and argon

    CERN Document Server

    Kroepelin, H; Hoffmann, K-U

    2013-01-01

    Thermodynamic Diagrams for High Temperature Plasmas of Air, Air-Carbon, Carbon-Hydrogen Mixtures, and Argon provides information relating to the properties of equilibrium gas plasmas formed from hydrocarbons, from air without argon, from pure argon, and from mixtures of air and carbon at various compositions, temperatures and pressures. The data are presented in graphical rather than tabular form to provide a clearer picture of the plasma processes investigated. This book is composed of four chapters, and begins with the introduction to the characteristics of plasmas, with emphasis on their th

  14. Evaluation of flow hydrodynamics in a pilot-scale dissolved air flotation tank: a comparison between CFD and experimental measurements.

    Science.gov (United States)

    Lakghomi, B; Lawryshyn, Y; Hofmann, R

    2015-01-01

    Computational fluid dynamics (CFD) models of dissolved air flotation (DAF) have shown formation of stratified flow (back and forth horizontal flow layers at the top of the separation zone) and its impact on improved DAF efficiency. However, there has been a lack of experimental validation of CFD predictions, especially in the presence of solid particles. In this work, for the first time, both two-phase (air-water) and three-phase (air-water-solid particles) CFD models were evaluated at pilot scale using measurements of residence time distribution, bubble layer position and bubble-particle contact efficiency. The pilot-scale results confirmed the accuracy of the CFD model for both two-phase and three-phase flows, but showed that the accuracy of the three-phase CFD model would partly depend on the estimation of bubble-particle attachment efficiency.

  15. Experimental and modeling study of fluidized bed granulation: Effect of binder flow rate and fluidizing air velocity

    Directory of Open Access Journals (Sweden)

    U. Vengateson

    2016-12-01

    Full Text Available Fluidized bed granulation is a widely used technique of producing granules in pharmaceutical, food, detergent, and fertilizer industries. In this study, fluidized bed granulation of two powders – wheat flour and rice powder – with water as binder is studied experimentally and by modeling. The effects of two process parameters – binder flow rate, fluidizing air velocity – are determined. Experimental results show that increasing the binder flow rate favors the formation of bigger granules while increasing fluidizing air velocity leads to a decrease in average granule diameter. Population balance model with suitable form of coalescence kernel (β has been used to describe the granule growth. Later, this kernel is linked with process parameters – binder flow rate and fluidizing air velocity.

  16. High-speed flow visualization in a pump-turbine under off-design operating conditions

    Energy Technology Data Exchange (ETDEWEB)

    Hasmatuchi, V; Roth, S; Botero, F; Avellan, F; Farhat, M, E-mail: vlad.hasmatuchi@epfl.c [Laboratory for Hydraulic Machines, Ecole Polytechnique Federale de Lausanne Av. de Cour 33bis, Lausanne, CH-1007 (Switzerland)

    2010-08-15

    The flow hydrodynamics in a low specific speed radial pump-turbine reduced scale model is experimentally investigated under off-design operating conditions in generating mode. Wall pressure measurements, in the stator, synchronized with high-speed flow visualizations in the vaneless space between the impeller and the guide vanes using air bubbles injection are performed. When starting from the best efficiency point and increasing the runner speed, a significant increase of the pressure fluctuations is observed mainly in channels between wicket gates. The spectral analysis shows a rise of one stall cell, rotating with about 70% of the impeller frequency, at runaway, which further increases as the zero discharge condition is approached. Then a specific image processing technique is detailed and applied to create a synthetic instantaneous view of the flow pattern on the entire guide vanes circumference for an operating point in turbine-brake mode, where backflow and vortices accompany the stall passage.

  17. Pulsed operation of high-power light emitting diodes for imaging flow velocimetry

    Science.gov (United States)

    Willert, C.; Stasicki, B.; Klinner, J.; Moessner, S.

    2010-07-01

    High-powered light emitting diodes (LED) are investigated for possible uses as light sources in flow diagnostics, in particular, as an alternative to laser-based illumination in particle imaging flow velocimetry in side-scatter imaging arrangements. Recent developments in solid state illumination resulted in mass-produced LEDs that provide average radiant power in excess of 10 W. By operating these LEDs with short duration, pulsed currents that are considerably beyond their continuous current damage threshold, light pulses can be generated that are sufficient to illuminate and image micron-sized particles in flow velocimetry. Time-resolved PIV measurements in water at a framing rate of 2kHz are presented. The feasibility of LED-based PIV measurements in air is also demonstrated.

  18. An improved high-performance lithium-air battery

    Science.gov (United States)

    Jung, Hun-Gi; Hassoun, Jusef; Park, Jin-Bum; Sun, Yang-Kook; Scrosati, Bruno

    2012-07-01

    Although dominating the consumer electronics markets as the power source of choice for popular portable devices, the common lithium battery is not yet suited for use in sustainable electrified road transport. The development of advanced, higher-energy lithium batteries is essential in the rapid establishment of the electric car market. Owing to its exceptionally high energy potentiality, the lithium-air battery is a very appealing candidate for fulfilling this role. However, the performance of such batteries has been limited to only a few charge-discharge cycles with low rate capability. Here, by choosing a suitable stable electrolyte and appropriate cell design, we demonstrate a lithium-air battery capable of operating over many cycles with capacity and rate values as high as 5,000 mAh gcarbon-1 and 3 A gcarbon-1, respectively. For this battery we estimate an energy density value that is much higher than those offered by the currently available lithium-ion battery technology.

  19. Flow and containment characteristics of a sash-less, variable-height inclined air-curtain fume hood.

    Science.gov (United States)

    Huang, Rong Fung; Chen, Jia-Kun; Hung, Wei-Lun

    2013-08-01

    To increase containment efficiency and reduce energy consumption, a sash-less, variable-height inclined air-curtain fume hood (sIAC hood) was developed and tested by a laser-assisted flow visualization technique and tracer-gas detection method. This novel design requires neither sash nor baffle. The sIAC hood employed the inclined push-pull air-curtain technique and two deflection plates installed on the side walls of the hood to induce a tetra-vortex flow structure. The results of flow visualization showed that the slot for suction flow, offset from the slot for the up-blowing jet, caused the air curtain to incline towards the rear wall, thus enhancing the robustness of the tetra-vortex flow structure. Such a flow structure could reduce the influence of draught and human walk-by across the hood face. The containment around the central area of the hood was isolated by the inclined push-pull air curtain. The pollutants carried by the reverse flow induced by the flow separation were guided by the deflection plates from the side walls towards the rear, thus contributing to the formation of the tetra-vortex flow structure. The up/down movable ceiling positioned the suction slot close to the device's pollutant emission opening, but left room (less than 50 cm) for unrestricted hand movement. Testing was carried out based on the methodology described in EN14175. The results of a static test showed that small face velocities of 0.25 and 0.16 m s(-1) were enough to obtain nearly null leakage levels for low and tall pollutant sources. The results of a traversing plate test showed that the face velocity, 0.32 m s(-1), would cause negligibly small leakage levels. The sIAC hood could obtain significantly higher containment efficiency than a conventional hood by operating at a face velocity significantly lower than that of conventional hoods.

  20. The aerodynamic effects of wheelspace coolant injection into the mainstream flow of a high pressure gas turbine

    Science.gov (United States)

    McLean, Christopher Elliot

    Modern gas turbine engines operate with mainstream gas temperatures exceeding 1450°C in the high-pressure turbine stage. Unlike turbine blades, rotor disks and other internal components are not designed to withstand the extreme temperatures found in mainstream flow. In modern gas turbines, cooling air is pumped into the wheelspace cavities to prevent mainstream gas ingestion and then exits through a seal between the rotor and the nozzle guide vane (NGV) thereby mixing with the mainstream flow. The primary purpose for the wheelspace cooling air is the cooling of the turbine wheelspace. However, secondary effects arise from the mixing of the spent cooling air with the mainstream flow. The exiting cooling air is mixed with the hot mainstream flow effecting the aerodynamic and performance characteristics of the turbine stage. The physics underlying this mixing process and its effects on stage performance are not yet fully understood. The relative aerodynamic and performance effects associated with rotor - NGV gap coolant injections were investigated in the Axial Flow Turbine Research Facility (AFTRF) of the Center for Gas Turbines and Power of The Pennsylvania State University. This study quantifies the secondary effects of the coolant injection on the aerodynamic and performance character of the turbines main stream flow for root injection, radial cooling, and impingement cooling. Measurement and analysis of the cooling effects were performed in both stationary and rotational frames of reference. The AFTRF is unique in its ability to perform long duration cooling measurements in the stationary and rotating frames. The effects of wheelspace coolant mixing with the mainstream flow on total-to-total efficiency, energy transport, three dimensional velocity field, and loading coefficient were investigated. Overall, it was found that a small quantity (1%) of cooling air can have significant effects on the performance character and exit conditions of the high pressure stage