WorldWideScience

Sample records for high accuracy scores

  1. Accuracy of Pooled-Cohort Equation and SCORE cardiovascular risk calculators to identify individuals with high coronary atherosclerotic burden - implications for statin treatment.

    Science.gov (United States)

    Tralhão, António; Ferreira, António M; Gonçalves, Pedro de Araújo; Rodrigues, Rita; Costa, Cátia; Guerreiro, Sara; Cardim, Nuno; Marques, Hugo

    2016-11-01

    Different cardiovascular risk calculators and risk-based thresholds for initiating statin therapy are currently in use. Using coronary computed tomography angiography, we sought to compare the Pooled-Cohort Equation [atherosclerotic cardiovascular disease (ASCVD) score] with the Systematic COronary Risk Evaluation (SCORE) in the identification of patients with high coronary atherosclerotic burden. In a single-center prospective registry of patients undergoing coronary computed tomography angiography, we identified individuals aged 40-75 years without diabetes or known cardiovascular disease. Cardiovascular risk and eligibility for statin therapy were determined individually on the basis of the two calculators and the guidelines that endorse them. Coronary atherosclerotic burden was assessed by coronary calcium score, presence of stenosis greater than or equal to 50%, and several measures of plaque severity and extension. In the 327 patients assessed (181 men, mean age 59±9 years), the median SCORE and ASCVD values were 2.6 and 9.7%, respectively. Compared with SCORE, the ASCVD calculator showed greater discriminative power to identify patients with calcium score greater than or equal to 300 [C-statistic 0.74, 95% confidence interval (CI) 0.67-0.82 vs. 0.69, 95% CI 0.61-0.78, P=0.008] and showed a trend toward better identification of patients with obstructive stenosis (C-statistic 0.72, 95% CI 0.64-0.80 vs. 0.68, 95% CI 0.60-0.76, P=0.053). The proportion of statin-eligible patients would be higher with the SCORE-based criteria, particularly among individuals with little or no detectable coronary atherosclerosis. The SCORE calculator seems to be less discriminative than the ASCVD equation in identifying patients with high atherosclerotic burden. Current SCORE-based criteria would assign statin therapy to a larger proportion of patients with low-risk features, which could result in a lower yield of cholesterol-reducing strategies.

  2. Modeling Linkage Disequilibrium Increases Accuracy of Polygenic Risk Scores.

    Science.gov (United States)

    Vilhjálmsson, Bjarni J; Yang, Jian; Finucane, Hilary K; Gusev, Alexander; Lindström, Sara; Ripke, Stephan; Genovese, Giulio; Loh, Po-Ru; Bhatia, Gaurav; Do, Ron; Hayeck, Tristan; Won, Hong-Hee; Kathiresan, Sekar; Pato, Michele; Pato, Carlos; Tamimi, Rulla; Stahl, Eli; Zaitlen, Noah; Pasaniuc, Bogdan; Belbin, Gillian; Kenny, Eimear E; Schierup, Mikkel H; De Jager, Philip; Patsopoulos, Nikolaos A; McCarroll, Steve; Daly, Mark; Purcell, Shaun; Chasman, Daniel; Neale, Benjamin; Goddard, Michael; Visscher, Peter M; Kraft, Peter; Patterson, Nick; Price, Alkes L

    2015-10-01

    Polygenic risk scores have shown great promise in predicting complex disease risk and will become more accurate as training sample sizes increase. The standard approach for calculating risk scores involves linkage disequilibrium (LD)-based marker pruning and applying a p value threshold to association statistics, but this discards information and can reduce predictive accuracy. We introduce LDpred, a method that infers the posterior mean effect size of each marker by using a prior on effect sizes and LD information from an external reference panel. Theory and simulations show that LDpred outperforms the approach of pruning followed by thresholding, particularly at large sample sizes. Accordingly, predicted R(2) increased from 20.1% to 25.3% in a large schizophrenia dataset and from 9.8% to 12.0% in a large multiple sclerosis dataset. A similar relative improvement in accuracy was observed for three additional large disease datasets and for non-European schizophrenia samples. The advantage of LDpred over existing methods will grow as sample sizes increase. Copyright © 2015 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  3. Modeling Linkage Disequilibrium Increases Accuracy of Polygenic Risk Scores

    Science.gov (United States)

    Vilhjálmsson, Bjarni J.; Yang, Jian; Finucane, Hilary K.; Gusev, Alexander; Lindström, Sara; Ripke, Stephan; Genovese, Giulio; Loh, Po-Ru; Bhatia, Gaurav; Do, Ron; Hayeck, Tristan; Won, Hong-Hee; Ripke, Stephan; Neale, Benjamin M.; Corvin, Aiden; Walters, James T.R.; Farh, Kai-How; Holmans, Peter A.; Lee, Phil; Bulik-Sullivan, Brendan; Collier, David A.; Huang, Hailiang; Pers, Tune H.; Agartz, Ingrid; Agerbo, Esben; Albus, Margot; Alexander, Madeline; Amin, Farooq; Bacanu, Silviu A.; Begemann, Martin; Belliveau, Richard A.; Bene, Judit; Bergen, Sarah E.; Bevilacqua, Elizabeth; Bigdeli, Tim B.; Black, Donald W.; Bruggeman, Richard; Buccola, Nancy G.; Buckner, Randy L.; Byerley, William; Cahn, Wiepke; Cai, Guiqing; Campion, Dominique; Cantor, Rita M.; Carr, Vaughan J.; Carrera, Noa; Catts, Stanley V.; Chambert, Kimberly D.; Chan, Raymond C.K.; Chen, Ronald Y.L.; Chen, Eric Y.H.; Cheng, Wei; Cheung, Eric F.C.; Chong, Siow Ann; Cloninger, C. Robert; Cohen, David; Cohen, Nadine; Cormican, Paul; Craddock, Nick; Crowley, James J.; Curtis, David; Davidson, Michael; Davis, Kenneth L.; Degenhardt, Franziska; Del Favero, Jurgen; DeLisi, Lynn E.; Demontis, Ditte; Dikeos, Dimitris; Dinan, Timothy; Djurovic, Srdjan; Donohoe, Gary; Drapeau, Elodie; Duan, Jubao; Dudbridge, Frank; Durmishi, Naser; Eichhammer, Peter; Eriksson, Johan; Escott-Price, Valentina; Essioux, Laurent; Fanous, Ayman H.; Farrell, Martilias S.; Frank, Josef; Franke, Lude; Freedman, Robert; Freimer, Nelson B.; Friedl, Marion; Friedman, Joseph I.; Fromer, Menachem; Genovese, Giulio; Georgieva, Lyudmila; Gershon, Elliot S.; Giegling, Ina; Giusti-Rodrguez, Paola; Godard, Stephanie; Goldstein, Jacqueline I.; Golimbet, Vera; Gopal, Srihari; Gratten, Jacob; Grove, Jakob; de Haan, Lieuwe; Hammer, Christian; Hamshere, Marian L.; Hansen, Mark; Hansen, Thomas; Haroutunian, Vahram; Hartmann, Annette M.; Henskens, Frans A.; Herms, Stefan; Hirschhorn, Joel N.; Hoffmann, Per; Hofman, Andrea; Hollegaard, Mads V.; Hougaard, David M.; Ikeda, Masashi; Joa, Inge; Julia, Antonio; Kahn, Rene S.; Kalaydjieva, Luba; Karachanak-Yankova, Sena; Karjalainen, Juha; Kavanagh, David; Keller, Matthew C.; Kelly, Brian J.; Kennedy, James L.; Khrunin, Andrey; Kim, Yunjung; Klovins, Janis; Knowles, James A.; Konte, Bettina; Kucinskas, Vaidutis; Kucinskiene, Zita Ausrele; Kuzelova-Ptackova, Hana; Kahler, Anna K.; Laurent, Claudine; Keong, Jimmy Lee Chee; Lee, S. Hong; Legge, Sophie E.; Lerer, Bernard; Li, Miaoxin; Li, Tao; Liang, Kung-Yee; Lieberman, Jeffrey; Limborska, Svetlana; Loughland, Carmel M.; Lubinski, Jan; Lnnqvist, Jouko; Macek, Milan; Magnusson, Patrik K.E.; Maher, Brion S.; Maier, Wolfgang; Mallet, Jacques; Marsal, Sara; Mattheisen, Manuel; Mattingsdal, Morten; McCarley, Robert W.; McDonald, Colm; McIntosh, Andrew M.; Meier, Sandra; Meijer, Carin J.; Melegh, Bela; Melle, Ingrid; Mesholam-Gately, Raquelle I.; Metspalu, Andres; Michie, Patricia T.; Milani, Lili; Milanova, Vihra; Mokrab, Younes; Morris, Derek W.; Mors, Ole; Mortensen, Preben B.; Murphy, Kieran C.; Murray, Robin M.; Myin-Germeys, Inez; Mller-Myhsok, Bertram; Nelis, Mari; Nenadic, Igor; Nertney, Deborah A.; Nestadt, Gerald; Nicodemus, Kristin K.; Nikitina-Zake, Liene; Nisenbaum, Laura; Nordin, Annelie; O’Callaghan, Eadbhard; O’Dushlaine, Colm; O’Neill, F. Anthony; Oh, Sang-Yun; Olincy, Ann; Olsen, Line; Van Os, Jim; Pantelis, Christos; Papadimitriou, George N.; Papiol, Sergi; Parkhomenko, Elena; Pato, Michele T.; Paunio, Tiina; Pejovic-Milovancevic, Milica; Perkins, Diana O.; Pietilinen, Olli; Pimm, Jonathan; Pocklington, Andrew J.; Powell, John; Price, Alkes; Pulver, Ann E.; Purcell, Shaun M.; Quested, Digby; Rasmussen, Henrik B.; Reichenberg, Abraham; Reimers, Mark A.; Richards, Alexander L.; Roffman, Joshua L.; Roussos, Panos; Ruderfer, Douglas M.; Salomaa, Veikko; Sanders, Alan R.; Schall, Ulrich; Schubert, Christian R.; Schulze, Thomas G.; Schwab, Sibylle G.; Scolnick, Edward M.; Scott, Rodney J.; Seidman, Larry J.; Shi, Jianxin; Sigurdsson, Engilbert; Silagadze, Teimuraz; Silverman, Jeremy M.; Sim, Kang; Slominsky, Petr; Smoller, Jordan W.; So, Hon-Cheong; Spencer, Chris C.A.; Stahl, Eli A.; Stefansson, Hreinn; Steinberg, Stacy; Stogmann, Elisabeth; Straub, Richard E.; Strengman, Eric; Strohmaier, Jana; Stroup, T. Scott; Subramaniam, Mythily; Suvisaari, Jaana; Svrakic, Dragan M.; Szatkiewicz, Jin P.; Sderman, Erik; Thirumalai, Srinivas; Toncheva, Draga; Tooney, Paul A.; Tosato, Sarah; Veijola, Juha; Waddington, John; Walsh, Dermot; Wang, Dai; Wang, Qiang; Webb, Bradley T.; Weiser, Mark; Wildenauer, Dieter B.; Williams, Nigel M.; Williams, Stephanie; Witt, Stephanie H.; Wolen, Aaron R.; Wong, Emily H.M.; Wormley, Brandon K.; Wu, Jing Qin; Xi, Hualin Simon; Zai, Clement C.; Zheng, Xuebin; Zimprich, Fritz; Wray, Naomi R.; Stefansson, Kari; Visscher, Peter M.; Adolfsson, Rolf; Andreassen, Ole A.; Blackwood, Douglas H.R.; Bramon, Elvira; Buxbaum, Joseph D.; Børglum, Anders D.; Cichon, Sven; Darvasi, Ariel; Domenici, Enrico; Ehrenreich, Hannelore; Esko, Tonu; Gejman, Pablo V.; Gill, Michael; Gurling, Hugh; Hultman, Christina M.; Iwata, Nakao; Jablensky, Assen V.; Jonsson, Erik G.; Kendler, Kenneth S.; Kirov, George; Knight, Jo; Lencz, Todd; Levinson, Douglas F.; Li, Qingqin S.; Liu, Jianjun; Malhotra, Anil K.; McCarroll, Steven A.; McQuillin, Andrew; Moran, Jennifer L.; Mortensen, Preben B.; Mowry, Bryan J.; Nthen, Markus M.; Ophoff, Roel A.; Owen, Michael J.; Palotie, Aarno; Pato, Carlos N.; Petryshen, Tracey L.; Posthuma, Danielle; Rietschel, Marcella; Riley, Brien P.; Rujescu, Dan; Sham, Pak C.; Sklar, Pamela; St. Clair, David; Weinberger, Daniel R.; Wendland, Jens R.; Werge, Thomas; Daly, Mark J.; Sullivan, Patrick F.; O’Donovan, Michael C.; Kraft, Peter; Hunter, David J.; Adank, Muriel; Ahsan, Habibul; Aittomäki, Kristiina; Baglietto, Laura; Berndt, Sonja; Blomquist, Carl; Canzian, Federico; Chang-Claude, Jenny; Chanock, Stephen J.; Crisponi, Laura; Czene, Kamila; Dahmen, Norbert; Silva, Isabel dos Santos; Easton, Douglas; Eliassen, A. Heather; Figueroa, Jonine; Fletcher, Olivia; Garcia-Closas, Montserrat; Gaudet, Mia M.; Gibson, Lorna; Haiman, Christopher A.; Hall, Per; Hazra, Aditi; Hein, Rebecca; Henderson, Brian E.; Hofman, Albert; Hopper, John L.; Irwanto, Astrid; Johansson, Mattias; Kaaks, Rudolf; Kibriya, Muhammad G.; Lichtner, Peter; Lindström, Sara; Liu, Jianjun; Lund, Eiliv; Makalic, Enes; Meindl, Alfons; Meijers-Heijboer, Hanne; Müller-Myhsok, Bertram; Muranen, Taru A.; Nevanlinna, Heli; Peeters, Petra H.; Peto, Julian; Prentice, Ross L.; Rahman, Nazneen; Sánchez, María José; Schmidt, Daniel F.; Schmutzler, Rita K.; Southey, Melissa C.; Tamimi, Rulla; Travis, Ruth; Turnbull, Clare; Uitterlinden, Andre G.; van der Luijt, Rob B.; Waisfisz, Quinten; Wang, Zhaoming; Whittemore, Alice S.; Yang, Rose; Zheng, Wei; Kathiresan, Sekar; Pato, Michele; Pato, Carlos; Tamimi, Rulla; Stahl, Eli; Zaitlen, Noah; Pasaniuc, Bogdan; Belbin, Gillian; Kenny, Eimear E.; Schierup, Mikkel H.; De Jager, Philip; Patsopoulos, Nikolaos A.; McCarroll, Steve; Daly, Mark; Purcell, Shaun; Chasman, Daniel; Neale, Benjamin; Goddard, Michael; Visscher, Peter M.; Kraft, Peter; Patterson, Nick; Price, Alkes L.

    2015-01-01

    Polygenic risk scores have shown great promise in predicting complex disease risk and will become more accurate as training sample sizes increase. The standard approach for calculating risk scores involves linkage disequilibrium (LD)-based marker pruning and applying a p value threshold to association statistics, but this discards information and can reduce predictive accuracy. We introduce LDpred, a method that infers the posterior mean effect size of each marker by using a prior on effect sizes and LD information from an external reference panel. Theory and simulations show that LDpred outperforms the approach of pruning followed by thresholding, particularly at large sample sizes. Accordingly, predicted R2 increased from 20.1% to 25.3% in a large schizophrenia dataset and from 9.8% to 12.0% in a large multiple sclerosis dataset. A similar relative improvement in accuracy was observed for three additional large disease datasets and for non-European schizophrenia samples. The advantage of LDpred over existing methods will grow as sample sizes increase. PMID:26430803

  4. Enhancement of transparency and accuracy of credit scoring models through genetic fuzzy classifier

    Directory of Open Access Journals (Sweden)

    Raja N. Ainon

    2010-04-01

    Full Text Available Credit risk evaluation systems play an important role in the financial decision-making by enabling faster credit decisions, reducing the cost of credit analysis and diminishing possible risks. Credit scoring is the most commonly used technique for evaluating the creditworthiness of the credit applicants. The credit models built with this technique should satisfy two important criteria, namely accuracy, which measures the capability of predicting the behaviour of the customers, and transparency, which reflects the ability of the model to describe the input-output relation in an understandable way. In our paper, two credit scoring models are proposed using two types of fuzzy systems, namely Takagi-Sugeno (TS and Mamdani types. The accuracy and transparency of these two models have been optimised. The TS fuzzy credit scoring model is generated using subtractive clustering method while the Mamdani fuzzy system is extracted using fuzzy C-means clustering algorithm. The accuracy and transparency of the two resulting fuzzy credit scoring models are optimised using two multi-objective evolutionary techniques. The potential of the proposed modelling approaches for enhancing the transparency of the credit scoring models while maintaining the classification accuracy is illustrated using two benchmark real world data sets. The TS fuzzy system is found to be highly accurate and computationally efficient while the Mamdani fuzzy system is highly transparent, intuitive and humanly understandable.

  5. The accuracy rate of Alvarado score, ultrasonography, and ...

    African Journals Online (AJOL)

    2013-09-30

    Sep 30, 2013 ... the patients have atypical clinical and laboratory findings. In ... recorded on the study form for data collection. The Alvarado score was calculated as described in the literature.[5] The Alvarado score is a 10-point scoring system.

  6. A new scoring function for protein-protein docking that identifies native structures with unprecedented accuracy

    DEFF Research Database (Denmark)

    Moreira, Irina S.; da Silva Martins, João Miguel; Coimbra, João T.S.

    2015-01-01

    Protein-protein (P-P) 3D structures are fundamental to structural biology and drug discovery. However, most of them have never been determined. Many docking algorithms were developed for that purpose, but they have a very limited accuracy in generating native-like structures and identifying...... the most correct one, in particular when a single answer is asked for. With such a low success rate it is difficult to point out one docked structure as being native-like. Here we present a new, high accuracy, scoring method to identify the 3D structure of P-P complexes among a set of trial poses...... the trial structures and identifies the native-like structures with unprecedented accuracy (∼94%), providing the correct P-P 3D structures that biochemists and molecular biologists need to pursue their studies. With such a success rate, the bottleneck of protein-protein docking moves from the scoring...

  7. High accuracy flexural hinge development

    Science.gov (United States)

    Santos, I.; Ortiz de Zárate, I.; Migliorero, G.

    2005-07-01

    This document provides a synthesis of the technical results obtained in the frame of the HAFHA (High Accuracy Flexural Hinge Assembly) development performed by SENER (in charge of design, development, manufacturing and testing at component and mechanism levels) with EADS Astrium as subcontractor (in charge of doing an inventory of candidate applications among existing and emerging projects, establishing the requirements and perform system level testing) under ESA contract. The purpose of this project has been to develop a competitive technology for a flexural pivot, usuable in highly accurate and dynamic pointing/scanning mechanisms. Compared with other solutions (e.g. magnetic or ball bearing technologies) flexural hinges are the appropriate technology for guiding with accuracy a mobile payload over a limited angular ranges around one rotation axes.

  8. Modeling Linkage Disequilibrium Increases Accuracy of Polygenic Risk Scores

    DEFF Research Database (Denmark)

    Vilhjálmsson, Bjarni J; Yang, Jian; Finucane, Hilary K

    2015-01-01

    to association statistics, but this discards information and can reduce predictive accuracy. We introduce LDpred, a method that infers the posterior mean effect size of each marker by using a prior on effect sizes and LD information from an external reference panel. Theory and simulations show that LDpred...

  9. Semi-automated scoring of pulmonary emphysema from X-ray CT: Trainee reproducibility and accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Owrangi, Amir M., E-mail: aowrangi@robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Entwistle, Brandon, E-mail: Brandon.Entwistle@londonhospitals.ca; Lu, Andrew, E-mail: Andrew.Lu@londonhospitals.ca; Chiu, Jack, E-mail: Jack.Chiu@londonhospitals.ca; Hussain, Nabil, E-mail: Nabil.Hussain@londonhospitals.ca; Etemad-Rezai, Roya, E-mail: Roya.EtemadRezai@lhsc.on.ca; Parraga, Grace, E-mail: gparraga@robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Graduate Program in Biomedical Engineering, Department of Medical Imaging, Department of Medical Biophysics, The University of Western Ontario, London (Canada)

    2013-11-01

    Objective: We developed a semi-automated tool to quantify emphysema from thoracic X-ray multi-detector (64-slice) computed tomography (CT) for training purposes and multi-reader studies. Materials and Methods: Thoracic X-ray CT was acquired in 93 ex-smokers, who were evaluated by six trainees with little or no expertise (trainees) and a single experienced thoracic radiologist (expert). A graphic user interface (GUI) was developed for emphysema quantification based on the percentile of lung where a score of 0 = no abnormalities, 1 = 1–25%, 2 = 26–50%, 3 = 51–75% and 4 = 76–100% for each lung side/slice. Trainees blinded to subject characteristics scored randomized images twice; accuracy was determined by comparison to expert scores, density histogram 15th percentile (HU{sub 15}), relative area at −950 HU (RA{sub 950}), low attenuation clusters at −950 HU (LAC{sub 950}), −856 HU (LAC{sub 856}) and the diffusing capacity for carbon monoxide (DL{sub CO%pred}). Intra- and inter-observer reproducibility was evaluated using coefficients-of-variation (COV), intra-class (ICC) and Pearson correlations. Results: Trainee–expert correlations were significant (r = 0.85–0.97, p < 0.0001) and a significant trainee bias (0.15 ± 0.22) was observed. Emphysema score was correlated with RA{sub 950} (r = 0.88, p < 0.0001), HU{sub 15} (r = −0.77, p < 0.0001), LAC{sub 950} (r = 0.76, p < 0.0001), LAC{sub 856} (r = 0.74, p = 0.0001) and DL{sub CO%pred} (r = −0.71, p < 0.0001). Intra-observer reproducibility (COV = 4–27%; ICC = 0.75–0.94) was moderate to high for trainees; intra- and inter-observer COV were negatively and non-linearly correlated with emphysema score. Conclusion: We developed a GUI for rapid and interactive emphysema scoring that allows for comparison of multiple readers with clinical and radiological standards.

  10. Does Maximizing Information at the Cut Score Always Maximize Classification Accuracy and Consistency?

    Science.gov (United States)

    Wyse, Adam E.; Babcock, Ben

    2016-01-01

    A common suggestion made in the psychometric literature for fixed-length classification tests is that one should design tests so that they have maximum information at the cut score. Designing tests in this way is believed to maximize the classification accuracy and consistency of the assessment. This article uses simulated examples to illustrate…

  11. Accuracy of a combined score of zygote and embryo morphology for selecting the best embryos for IVF

    Institute of Scientific and Technical Information of China (English)

    Yu-li QIAN; Ying-hui YE; Chen-ming XU; Fan JIN; He-feng HUANG

    2008-01-01

    Objective:To evaluate the accuracy of a scoring system combining zygote and embryo morphology in predicting the outcome of in vitro fertilization(IVF)treatment.Methods:In a study group,117 consecutive IVF or intracytoplasmic sperm injection(ICSI) cycles with embryo transfer were carried out and 312 embryos were scored Using a combmed scoring system(CSS)of zygote and embryo morphology before transplantation.In a control group,a total of 420 IVF or ICSI cycles were carried out and 1176 embryos were scored using a cumulative embryo score(CES).The effects of the combined scoring system on the embryo implantation rate and pregnancy rate per cycle were analyzed.Results:Using the combined scoring system,the embryo implantation rate(27.6%)and the clinical pregnancy rate(48.7%)were significantly higher than those in the control group(20.8%and 38.6%,respectively).Also,the implantation rate of embryos scoring≥70 (38.5%:82 sacs/213 embryos)was significantly higher (P<0.001)than that of embryos scoring<70(4%:4 sacs/99 embryos).The pregnancy rate of patients with embryos scoring≥70 using the combined scoring system(66.7%)Was significantly higher(P<0.001)than that of patients with embryos scoring≥20 using the cumulative embryo score(59.0%).Conclusion:The results suggest that selecting embryos with a high Score(≥70)using the combined scoring system could inerease the implantation rate and pregnancy rate,and that using a scoring system combining assessments of human zygotes and pre-implantation embryos might predict IVF outcomes more accurately than using a cumulafive embryo score.

  12. A new adult appendicitis score improves diagnostic accuracy of acute appendicitis - a prospective study

    Science.gov (United States)

    2014-01-01

    Background The aim of the study was to construct a new scoring system for more accurate diagnostics of acute appendicitis. Applying the new score into clinical practice could reduce the need of potentially harmful diagnostic imaging. Methods This prospective study enrolled 829 adults presenting with clinical suspicion of appendicitis, including 392 (47%) patients with appendicitis. The collected data included clinical findings and symptoms together with laboratory tests (white cell count, neutrophil count and C-reactive protein), and the timing of the onset of symptoms. The score was constructed by logistic regression analysis using multiple imputations for missing values. Performance of the constructed score in patients with complete data (n = 725) was compared with Alvarado score and Appendicitis inflammatory response score. Results 343 (47%) of patients with complete data had appendicitis. 199 (58%) patients with appendicitis had score value at least 16 and were classified as high probability group with 93% specificity.Patients with score below 11 were classified as low probability of appendicitis. Only 4% of patients with appendicitis had a score below 11, and none of them had complicated appendicitis. In contrast, 207 (54%) of non-appendicitis patients had score below 11. There were no cases with complicated appendicitis in the low probability group. The area under ROC curve was significantly larger with the new score 0.882 (95% CI 0.858 – 0.906) compared with AUC of Alvarado score 0.790 (0.758 – 0.823) and Appendicitis inflammatory response score 0.810 (0.779 – 0.840). Conclusions The new diagnostic score is fast and accurate in categorizing patients with suspected appendicitis, and roughly halves the need of diagnostic imaging. PMID:24970111

  13. A structured interview guide for global impressions: increasing reliability and scoring accuracy for CNS trials

    Directory of Open Access Journals (Sweden)

    Targum Steven D

    2013-01-01

    Full Text Available Abstract Background The clinical global impression of severity (CGI-S scale is a frequently used rating instrument for the assessment of global severity of illness in Central Nervous System (CNS trials. Although scoring guidelines have been proposed to anchor these scores, the collection of sufficient documentation to support the derived score is not part of any standardized interview procedure. It is self evident that the absence of a standardized, documentary format can affect inter-rater reliability and may adversely affect the accuracy of the resulting data. Method We developed a structured interview guide for global impressions (SIGGI and evaluated the instrument in a 2-visit study of ambulatory patients with Major Depressive Disorder (MDD or schizophrenia. Blinded, site-independent raters listened to audio recorded SIGGI interviews administered by site-based CGI raters. We compared SIGGI-derived CGI-S scores between the two separate site-based raters and the site-independent raters. Results We found significant intraclass correlations (p = 0.001 on all SIGGI-derived CGI-S scores between two separate site-based CGI raters with each other (r = 0.768 and with a blinded, site-independent rater (r = 0.748 and r = 0.706 respectively and significant Pearson’s correlations between CGI-S scores with all MADRS validity comparisons for MDD and PANSS comparisons for schizophrenia (p- 0.001 in all cases. Compared to site-based raters, the site-independent raters gave identical “dual” CGI-S scores to 67.6% and 68.2% of subjects at visit 1 and 77.1% at visit 2. Conclusion We suggest that the SIGGI may improve the inter-rater reliability and scoring precision of the CGI-S and have broad applicability in CNS clinical trials.

  14. A knowledge-guided strategy for improving the accuracy of scoring functions in binding affinity prediction

    Directory of Open Access Journals (Sweden)

    Wang Renxiao

    2010-04-01

    Full Text Available Abstract Background Current scoring functions are not very successful in protein-ligand binding affinity prediction albeit their popularity in structure-based drug designs. Here, we propose a general knowledge-guided scoring (KGS strategy to tackle this problem. Our KGS strategy computes the binding constant of a given protein-ligand complex based on the known binding constant of an appropriate reference complex. A good training set that includes a sufficient number of protein-ligand complexes with known binding data needs to be supplied for finding the reference complex. The reference complex is required to share a similar pattern of key protein-ligand interactions to that of the complex of interest. Thus, some uncertain factors in protein-ligand binding may cancel out, resulting in a more accurate prediction of absolute binding constants. Results In our study, an automatic algorithm was developed for summarizing key protein-ligand interactions as a pharmacophore model and identifying the reference complex with a maximal similarity to the query complex. Our KGS strategy was evaluated in combination with two scoring functions (X-Score and PLP on three test sets, containing 112 HIV protease complexes, 44 carbonic anhydrase complexes, and 73 trypsin complexes, respectively. Our results obtained on crystal structures as well as computer-generated docking poses indicated that application of the KGS strategy produced more accurate predictions especially when X-Score or PLP alone did not perform well. Conclusions Compared to other targeted scoring functions, our KGS strategy does not require any re-parameterization or modification on current scoring methods, and its application is not tied to certain systems. The effectiveness of our KGS strategy is in theory proportional to the ever-increasing knowledge of experimental protein-ligand binding data. Our KGS strategy may serve as a more practical remedy for current scoring functions to improve their

  15. High Accuracy Imaging Polarimetry with NICMOS

    CERN Document Server

    Batcheldor, D; Hines, D C; Schmidt, G D; Axon, D J; Robinson, A; Sparks, W; Tadhunter, C

    2008-01-01

    The ability of NICMOS to perform high accuracy polarimetry is currently hampered by an uncalibrated residual instrumental polarization at a level of 1.2-1.5%. To better quantify and characterize this residual we obtained observations of three polarimetric standard stars at three separate space-craft roll angles. Combined with archival data, these observations were used to characterize the residual instrumental polarization to enable NICMOS to reach its full polarimetric potential. Using these data, we calculate values of the parallel transmission coefficients that reproduce the ground-based results for the polarimetric standards. The uncertainties associated with the parallel transmission coefficients, a result of the photometric repeatability of the observations, dominate the accuracy of p and theta. However, the new coefficients now enable imaging polarimetry of targets with p~1.0% at an accuracy of +/-0.6% and +/-15 degrees.

  16. The utility and accuracy of oral reading fluency score types in predicting reading comprehension.

    Science.gov (United States)

    Petscher, Yaacov; Kim, Young-Suk

    2011-02-01

    This study used data from the Dynamic Indicators of Basic Early Literacy Skills (DIBELS; Good & Kaminski, 2002) oral reading fluency (ORF) probes to examine variation among different ORF score types (i.e., the median of three passages, the mean of all three passages, the mean of passages 2 and 3, and the score from passage 3) in predicting reading comprehension as a function of student reading fluency level and to compare the screening accuracy of these score types in predicting student reading comprehension. The results revealed that the relation between oral reading fluency and reading comprehension varied as a function of students' oral reading fluency and that different score types had varying predictive validity for year-end reading comprehension. The mean of all three passages demonstrated a marginally better balance in screening efficiency from September to December of grade one (especially for low-performing students), whereas in grades two and three, the median score was the best predictor. Furthermore, across all grades, increasing reading rates were observed for the three administered passages within an assessment period. The observed patterns mimicked previous experimental studies (Francis et al., 2008; Jenkins, Graff, & Miglioretti, 2009), suggesting that practice effects are an important consideration in the administration of multiple passages assessing oral reading fluency. Copyright © 2010 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  17. High accuracy FIONA-AFM hybrid imaging.

    Science.gov (United States)

    Fronczek, D N; Quammen, C; Wang, H; Kisker, C; Superfine, R; Taylor, R; Erie, D A; Tessmer, I

    2011-04-01

    Multi-protein complexes are ubiquitous and play essential roles in many biological mechanisms. Single molecule imaging techniques such as electron microscopy (EM) and atomic force microscopy (AFM) are powerful methods for characterizing the structural properties of multi-protein and multi-protein-DNA complexes. However, a significant limitation to these techniques is the ability to distinguish different proteins from one another. Here, we combine high resolution fluorescence microscopy and AFM (FIONA-AFM) to allow the identification of different proteins in such complexes. Using quantum dots as fiducial markers in addition to fluorescently labeled proteins, we are able to align fluorescence and AFM information to ≥8nm accuracy. This accuracy is sufficient to identify individual fluorescently labeled proteins in most multi-protein complexes. We investigate the limitations of localization precision and accuracy in fluorescence and AFM images separately and their effects on the overall registration accuracy of FIONA-AFM hybrid images. This combination of the two orthogonal techniques (FIONA and AFM) opens a wide spectrum of possible applications to the study of protein interactions, because AFM can yield high resolution (5-10nm) information about the conformational properties of multi-protein complexes and the fluorescence can indicate spatial relationships of the proteins in the complexes.

  18. High Accuracy Transistor Compact Model Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Hembree, Charles E. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Mar, Alan [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Robertson, Perry J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspond- ingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirements require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantifi- cation of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transis- tors have been developed and are described in this report.

  19. FRAX Score Can Be Used to Avoid Superfluous DXA Scans in Detecting Osteoporosis in Celiac Disease: Accuracy of the FRAX Score in Celiac Patients.

    Science.gov (United States)

    Tortora, Raffaella; Imperatore, Nicola; Capone, Pietro; Gerbino, Nicolò; Rea, Matilde; Affinito, Giovanna; Caporaso, Nicola; Rispo, Antonio

    2017-06-15

    The Fracture Risk Assessment (FRAX) tool has been developed to estimate patients' 10-yr probability of fracture, thus establishing which patients should undergo dual-energy X-ray Absorptiometry (DXA) scan. This study aimed to evaluate if the FRAX tool can replace or optimize the use of DXA scan in celiac disease (CD). We prospectively enrolled all CD patients aged over 40 yr diagnosed at our third-level unit. At time of CD diagnosis, all patients underwent FRAX score calculation for risk of major osteoporotic and hip fractures and DXA scan (used as gold standard) to assess the accuracy of the FRAX score. The FRAX score calculation was based on the following 10 variables: age (>40 yr), sex (M/F), body mass index, history of previous fracture (yes/no), parent fractured hip (yes/no), current smoking (yes/no), use of steroids (yes/no), rheumatoid arthritis (yes/no), secondary osteoporosis (yes/no), and alcohol ≥3 units/d (yes/no). DXA assessment was performed within 1 week from FRAX calculation. The FRAX score was dichotomized as normal or pathologic in accordance with the National Osteoporosis Guideline Group. A total of 160 CD patients were enrolled (M/F = 20/140; mean age 48.7 yr). A pathologic FRAX score was evident in 14 out of 160 patients (8.7%), whereas osteoporosis based on DXA scan was found in 10 patients (6%) (κ = 0.6); 3 patients with osteoporosis (1.9%) showed a 10-yr risk of major fracture >10% according to the National Osteoporosis Guideline Group criteria. With regard to diagnostic accuracy, the FRAX score showed sensitivity of 0%, specificity of 91%, positive predictive value of 0%, and negative predictive value of 94%. The prevalence of osteoporosis in adult CD appears to be quite low and only a small proportion of patients would require a DXA investigation. The FRAX score could be an effective tool to avoid useless DXA scans in CD patients in view of its high negative predictive value. Copyright © 2017 The International Society

  20. High throughput sample processing and automated scoring

    Directory of Open Access Journals (Sweden)

    Gunnar eBrunborg

    2014-10-01

    Full Text Available The comet assay is a sensitive and versatile method for assessing DNA damage in cells. In the traditional version of the assay, there are many manual steps involved and few samples can be treated in one experiment. High throughput modifications have been developed during recent years, and they are reviewed and discussed. These modifications include accelerated scoring of comets; other important elements that have been studied and adapted to high throughput are cultivation and manipulation of cells or tissues before and after exposure, and freezing of treated samples until comet analysis and scoring. High throughput methods save time and money but they are useful also for other reasons: large-scale experiments may be performed which are otherwise not practicable (e.g., analysis of many organs from exposed animals, and human biomonitoring studies, and automation gives more uniform sample treatment and less dependence on operator performance. The high throughput modifications now available vary largely in their versatility, capacity, complexity and costs. The bottleneck for further increase of throughput appears to be the scoring.

  1. High accuracy 3-D laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a mono-static staring 3-D laser radar based on gated viewing with range accuracy below 1 m at 10 m and 1 cm at 100. We use a high sensitivity, fast, intensified CCD camera, and a Nd:Yag passively Q-switched 32.4 kHz pulsed green laser at 532 nm. The CCD has 752x582 pixels. Camera...

  2. Accuracy of a pediatric early warning score in the recognition of clinical deterioration.

    Science.gov (United States)

    Miranda, Juliana de Oliveira Freitas; Camargo, Climene Laura de; Nascimento, Carlito Lopes; Portela, Daniel Sales; Monaghan, Alan

    2017-07-10

    to evaluate the accuracy of the version of the Brighton Pediatric Early Warning Score translated and adapted for the Brazilian context, in the recognition of clinical deterioration. a diagnostic test study to measure the accuracy of the Brighton Pediatric Early Warning Score for the Brazilian context, in relation to a reference standard. The sample consisted of 271 children, aged 0 to 10 years, blindly evaluated by a nurse and a physician, specialists in pediatrics, with interval of 5 to 10 minutes between the evaluations, for the application of the Brighton Pediatric Early Warning Score for the Brazilian context and of the reference standard. The data were processed and analyzed using the Statistical Package for the Social Sciences and VassarStats.net programs. The performance of the Brighton Pediatric Early Warning Score for the Brazilian context was evaluated through the indicators of sensitivity, specificity, predictive values, area under the ROC curve, likelihood ratios and post-test probability. the Brighton Pediatric Early Warning Score for the Brazilian context showed sensitivity of 73.9%, specificity of 95.5%, positive predictive value of 73.3%, negative predictive value of 94.7%, area under Receiver Operating Characteristic Curve of 91.9% and the positive post-test probability was 80%. the Brighton Pediatric Early Warning Score for the Brazilian context, presented good performance, considered valid for the recognition of clinical deterioration warning signs of the children studied. avaliar a acurácia da versão traduzida e adaptada do Brighton Paediatric Early Warning Score para o contexto brasileiro, no reconhecimento da deterioração clínica. estudo de teste diagnóstico para medir a acurácia do Brighton Paediatric Early Warning Score, para o contexto brasileiro, em relação a um padrão de referência. A amostra foi composta por 271 crianças de 0 a 10 anos, avaliadas de forma cega por uma enfermeira e um médico, especialistas em pediatria, com

  3. Computing High Accuracy Power Spectra with Pico

    CERN Document Server

    Fendt, William A

    2007-01-01

    This paper presents the second release of Pico (Parameters for the Impatient COsmologist). Pico is a general purpose machine learning code which we have applied to computing the CMB power spectra and the WMAP likelihood. For this release, we have made improvements to the algorithm as well as the data sets used to train Pico, leading to a significant improvement in accuracy. For the 9 parameter nonflat case presented here Pico can on average compute the TT, TE and EE spectra to better than 1% of cosmic standard deviation for nearly all $\\ell$ values over a large region of parameter space. Performing a cosmological parameter analysis of current CMB and large scale structure data, we show that these power spectra give very accurate 1 and 2 dimensional parameter posteriors. We have extended Pico to allow computation of the tensor power spectrum and the matter transfer function. Pico runs about 1500 times faster than CAMB at the default accuracy and about 250,000 times faster at high accuracy. Training Pico can be...

  4. Using quality scores and longer reads improves accuracy of Solexa read mapping

    Directory of Open Access Journals (Sweden)

    Xuan Zhenyu

    2008-02-01

    Full Text Available Abstract Background Second-generation sequencing has the potential to revolutionize genomics and impact all areas of biomedical science. New technologies will make re-sequencing widely available for such applications as identifying genome variations or interrogating the oligonucleotide content of a large sample (e.g. ChIP-sequencing. The increase in speed, sensitivity and availability of sequencing technology brings demand for advances in computational technology to perform associated analysis tasks. The Solexa/Illumina 1G sequencer can produce tens of millions of reads, ranging in length from ~25–50 nt, in a single experiment. Accurately mapping the reads back to a reference genome is a critical task in almost all applications. Two sources of information that are often ignored when mapping reads from the Solexa technology are the 3' ends of longer reads, which contain a much higher frequency of sequencing errors, and the base-call quality scores. Results To investigate whether these sources of information can be used to improve accuracy when mapping reads, we developed the RMAP tool, which can map reads having a wide range of lengths and allows base-call quality scores to determine which positions in each read are more important when mapping. We applied RMAP to analyze data re-sequenced from two human BAC regions for varying read lengths, and varying criteria for use of quality scores. RMAP is freely available for downloading at http://rulai.cshl.edu/rmap/. Conclusion Our results indicate that significant gains in Solexa read mapping performance can be achieved by considering the information in 3' ends of longer reads, and appropriately using the base-call quality scores. The RMAP tool we have developed will enable researchers to effectively exploit this information in targeted re-sequencing projects.

  5. Fast and High Accuracy Wire Scanner

    CERN Document Server

    Koujili, M; Koopman, J; Ramos, D; Sapinski, M; De Freitas, J; Ait Amira, Y; Djerdir, A

    2009-01-01

    Scanning of a high intensity particle beam imposes challenging requirements on a Wire Scanner system. It is expected to reach a scanning speed of 20 m.s-1 with a position accuracy of the order of 1 μm. In addition a timing accuracy better than 1 millisecond is needed. The adopted solution consists of a fork holding a wire rotating by a maximum of 200°. Fork, rotor and angular position sensor are mounted on the same axis and located in a chamber connected to the beam vacuum. The requirements imply the design of a system with extremely low vibration, vacuum compatibility, radiation and temperature tolerance. The adopted solution consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside of the vacuum chamber and the stator installed outside. The accurate position sensor will be mounted on the rotary shaft inside of the vacuum chamber, has to resist a bake-out temperature of 200°C and ionizing radiation up to a dozen of kGy/year. A digital feedback controller allows maxi...

  6. High accuracy 3-D laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a mono-static staring 3-D laser radar based on gated viewing with range accuracy below 1 m at 10 m and 1 cm at 100. We use a high sensitivity, fast, intensified CCD camera, and a Nd:Yag passively Q-switched 32.4 kHz pulsed green laser at 532 nm. The CCD has 752x582 pixels. Camera...... shutter is controlled in steps of 100 ps. Camera delay is controlled in steps of 100 ps. Each laser pulse triggers the camera delay and shutter. A 3-D image is constructed from a sequence of 50-100 2-D reflectivity images, where each frame integrates about 700 laser pulses on the CCD. In 50 Hz video mode...

  7. High speed high stakes scoring rule: assessing the performance of a new scoring rule for digital asssesment

    NARCIS (Netherlands)

    Klinkenberg, S.

    2014-01-01

    In this paper we will present the results of a three year subsidized research project investigating the performance of a new scoring rule for digital assessment. The scoring rule incorporates response time and accuracy in an adaptive environment. The project aimed to assess the validity and reliabil

  8. A SINGLE STEP SCHEME WITH HIGH ACCURACY FOR PARABOLIC PROBLEM

    Institute of Scientific and Technical Information of China (English)

    陈传淼; 胡志刚

    2001-01-01

    A single step scheme with high accuracy for solving parabolic problem is proposed. It is shown that this scheme possesses good stability and fourth order accuracy with respect to both time and space variables, which are superconvergent.

  9. Accuracy and Radiation Dose Reduction Using Low-Voltage Computed Tomography Coronary Artery Calcium Scoring With Tin Filtration

    NARCIS (Netherlands)

    Tesche, Christian; De Cecco, Carlo N.; Vliegenthart, Rozemarijn; Albrecht, Moritz Moritz H.; Varga-Szemes, Akos; Duguay, Taylor M.; Ebersberger, Ullrich; Bayer, Richard R.; Canstein, Christian; Schmidt, Bernhard; Allmendinger, Thomas; Litwin, Sheldon E.; Morris, Pamela B.; Flohr, Thomas G.; Hoffmann, Ellen; Schoepf, U. Joseph

    2017-01-01

    This study prospectively investigated the accuracy and radiation dose reduction of CT coronary artery calcium scoring (CACS) using a 100 kVp acquisition protocol with tin filtration (Sn100 kVp) compared with the standard 120 kVp acquisition protocol; 70 patients (59% men, 62.1 10.7 years) who

  10. ACCURACY IN FOOTBALL: SCORING A GOAL AS THE ULTIMATE OBJECTIVE OF FOOTBALL GAME

    Directory of Open Access Journals (Sweden)

    Dejan Milenković

    2013-12-01

    Full Text Available The study included 60 young football players aged 10 and 11 years with the aim to examine the influence of motor skills on a specific accuracy in football. The following tests for assessment of motoric abilities were used: Coordination: jumping over the horizontal rope, envelope test, figure „8“ with bending; Flexibility: forward bend-standing upper-body rotation-touch, the splits, side-stepping with a baton; Balance: standing on one leg along the balance bench, standing on one leg with eyes closed, flamingo test. Tests for specific accuracy in football included: elevational accuracy by foot - vertical target, elevational accuracy by foot - horizontal target, linear accuracy by foot - vertical target, the hits of ball by foot on the wall after it rebounces from the surface, elevational accuracy by head - vertical target and elevational accuracy by head - horizontal target. Results obtained by processing the data applying canonical correlation and regression analysis indicated the indisputable influence of motor abilities of young football players on the majority of specific accuracy tests.

  11. Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Long-Jiang Zhang; Zhuo-Li Zhang; Chang-Sheng Zhou; Guang-Ming Lu (Dept. of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing Univ., Nanjing (China)), e-mail: cjr.luguangming@vip.163.com; Sheng-Yong Wu (Medical Imaging Inst. of Tianjin, Tianjin (China)); Jing Wang; Shi-Sen Jiang (Dept. of Cardiology, Jinling Hospital, Clinical School of Medical College, Nanjing Univ., Nanjing (China)); Ying Lu (Dept. of Radiology and Biomedical Imaging, Univ. of California, San Francisco, CA (United States))

    2010-09-15

    the sensitivity and specificity of CTCA (P<0.05). Conclusion: On a per-patient, per-vessel, and per-segment basis, dual-source CTCA has a high sensitivity and specificity for the diagnosis of coronary artery stenosis. Average HR has no effect on the diagnostic accuracy of CTCA, while HRV and calcium score have a statistically significant effect on the sensitivity and specificity of CTCA

  12. Methodology for high accuracy contact angle measurement.

    Science.gov (United States)

    Kalantarian, A; David, R; Neumann, A W

    2009-12-15

    A new version of axisymmetric drop shape analysis (ADSA) called ADSA-NA (ADSA-no apex) was developed for measuring interfacial properties for drop configurations without an apex. ADSA-NA facilitates contact angle measurements on drops with a capillary protruding into the drop. Thus a much simpler experimental setup, not involving formation of a complete drop from below through a hole in the test surface, may be used. The contact angles of long-chained alkanes on a commercial fluoropolymer, Teflon AF 1600, were measured using the new method. A new numerical scheme was incorporated into the image processing to improve the location of the contact points of the liquid meniscus with the solid substrate to subpixel resolution. The images acquired in the experiments were also analyzed by a different drop shape technique called theoretical image fitting analysis-axisymmetric interfaces (TIFA-AI). The results were compared with literature values obtained by means of the standard ADSA for sessile drops with the apex. Comparison of the results from ADSA-NA with those from TIFA-AI and ADSA reveals that, with different numerical strategies and experimental setups, contact angles can be measured with an accuracy of less than 0.2 degrees. Contact angles and surface tensions measured from drops with no apex, i.e., by means of ADSA-NA and TIFA-AI, were considerably less scattered than those from complete drops with apex. ADSA-NA was also used to explore sources of improvement in contact angle resolution. It was found that using an accurate value of surface tension as an input enhances the accuracy of contact angle measurements.

  13. HEART score and clinical gestalt have similar diagnostic accuracy for diagnosing ACS in an unselected population of patients with chest pain presenting in the ED.

    Science.gov (United States)

    Visser, Anniek; Wolthuis, Albert; Breedveld, Rob; ter Avest, Ewoud

    2015-08-01

    Acute coronary syndrome (ACS) can be a diagnostic challenge in the emergency department (ED). Recently, the HEART score was developed, a simple bedside scoring system that quantifies risk of ischaemic events in patients with undifferentiated chest pain presenting in the ED. In this prospective cohort study, we compared the diagnostic accuracy of HEART score and clinical gestalt (clinical judgement) for diagnosing ACS in an unselected population of patients with chest pain presenting to the ED. HEART score (0-10) and clinical gestalt (low risk, intermediate risk or high risk of ACS) were prospectively determined in the ED in 255 patients presenting with chest pain by the treating physician. The reference standard was the presence of ACS, which was defined as either acute myocardial infarction (AMI) or the occurrence of a major adverse cardiac event within 6 weeks after presentation in the ED. 75 out of 255 patients (29%) had an ACS. A HEART score ≤3 had a lower negative likelihood ratio (0.15 (0.06-0.36)) for ACS than a low risk based on clinical gestalt (0.35 (0.19-0.64)), whereas a high HEART score ≥7 had a higher positive likelihood ratio (5.2 (3.2-8.5) vs 3.1 (2.2-4.4)). However, c-statistic of HEART score was not significantly different from clinical gestalt (0.81 (0.76-0.86) vs 0.79 (0.73-0.84), p=0.13). Our study demonstrates that HEART score and clinical gestalt have similar diagnostic accuracy for diagnosing ACS in an unselected population of patients with chest pain presenting in the ED. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Accuracy of visual scoring and semi-quantification of ultrasound strain elastography--a phantom study.

    Directory of Open Access Journals (Sweden)

    Jonathan Frederik Carlsen

    Full Text Available PURPOSE: The aim of this study was to evaluate the performance of strain elastography in an elasticity phantom and to assess which factors influenced visual scoring, strain histograms and strain ratios. Furthermore this study aimed to evaluate the effect of observer experience on visual scorings. MATERIALS AND METHODS: Two operators examined 20 targets of various stiffness and size (16.7 to 2.5 mm in an elasticity phantom at a depth of 3.5 cm with a 5-18 MHz transducer. Two pre-settings were used yielding 80 scans. Eight evaluators, four experienced, four inexperienced, performed visual scorings. Cut-offs for semi-quantitative methods were established for prediction of target stiffness. Data was pooled in two categories allowing calculations of sensitivity and specificity. Statistical tests chi-square test and linear regression as relevant. RESULTS: Strain ratios and strain histograms were superior to visual scorings of both experienced and inexperienced observers (p = 0.025, strain histograms vs. experienced observers, p<0.001, strain histograms vs. inexperienced observers, p = 0.044 strain ratios vs. experienced observers and p = 0.002 strain ratios vs. inexperienced observers. No significant difference in predicting target stiffness between strain ratios and strain histograms (p = 0.83 nor between experienced and inexperienced observers (p = 0.054 was shown when using four categories. When pooling data in two groups (80 kPa/45 kPa vs. 14/8 kPa the difference between the observers became significant (p<0.001. Target size had a significant influence on strain ratios measurements (p = 0.017 and on visual scorings (p<0.001 but not on the strain histograms(p = 0.358. Observer experience had significant effect on visual scorings(p = 0.003. CONCLUSION: Strain ratios and strain histograms are superior to visual scoring in assessing target stiffness in a phantom. Target size had a significant impact on strain ratios and

  15. High accuracy GNSS based navigation in GEO

    Science.gov (United States)

    Capuano, Vincenzo; Shehaj, Endrit; Blunt, Paul; Botteron, Cyril; Farine, Pierre-André

    2017-07-01

    Although significant improvements in efficiency and performance of communication satellites have been achieved in the past decades, it is expected that the demand for new platforms in Geostationary Orbit (GEO) and for the On-Orbit Servicing (OOS) on the existing ones will continue to rise. Indeed, the GEO orbit is used for many applications including direct broadcast as well as communications. At the same time, Global Navigation Satellites System (GNSS), originally designed for land, maritime and air applications, has been successfully used as navigation system in Low Earth Orbit (LEO) and its further utilization for navigation of geosynchronous satellites becomes a viable alternative offering many advantages over present ground based methods. Following our previous studies of GNSS signal characteristics in Medium Earth Orbit (MEO), GEO and beyond, in this research we specifically investigate the processing of different GNSS signals, with the goal to determine the best navigation performance they can provide in a GEO mission. Firstly, a detailed selection among different GNSS signals and different combinations of them is discussed, taking into consideration the L1 and L5 frequency bands, and the GPS and Galileo constellations. Then, the implementation of an Orbital Filter is summarized, which adaptively fuses the GN1SS observations with an accurate orbital forces model. Finally, simulation tests of the navigation performance achievable by processing the selected combination of GNSS signals are carried out. The results obtained show an achievable positioning accuracy of less than one meter. In addition, hardware-in-the-loop tests are presented using a COTS receiver connected to our GNSS Spirent simulator, in order to collect real-time hardware-in-the-loop observations and process them by the proposed navigation module.

  16. The accuracy of polyuria, polydipsia, polyphagia, and Indian Diabetes Risk Score in adults screened for diabetes mellitus type-II

    Directory of Open Access Journals (Sweden)

    Shivshakti D Pawar

    2017-01-01

    Full Text Available Context: The World Health Organization report suggests that over 19% of the world's diabetic population currently resides in India. Unfortunately, >50% of the diabetics in India are unaware about their diabetic status. In the poor income country like India, it is essential to use cost-effective methods for screening for diabetes, and traditionally using three classical symptoms and Indian Diabetes Risk Score (IDRS tool is helpful but, data regarding their diagnostic accuracy is very less. Objective: (1 To assess the diagnostic accuracy of polyuria, polydipsia, polyphagia, and IDRS for detecting diabetes. Settings and Design: Six hundred and seventy-seven adult individuals> 20 years of age were screened for diabetes and assessed polyuria, polydipsia, polyphagia, and IDRS score. All were subjected for postprandial blood glucose level. Subjects and Methods: For diagnostic accuracy sensitivity, specificity, positive and negative predictive values, likelihood ratios (LRs, for positive and negative tests, and accuracy was calculated for each symptom. Similarly, by receiver operative curve (ROC curve analysis, we carried out sensitivity and specificity of IDRS. Results: There was statistically significant association between these three classical symptoms and diabetes status of individuals. When present, all these three symptoms carried 7.34% sensitivity and 98.42% specificity with positive predictive value 47.06% and NPV 84.70%, LR+4.36, LR−0.94 with accuracy of 85%. The optimum cutoff value of IDRS score was> 50, which carried sensitivity 73%, specificity 58.7%, and area under curve for ROC was 68% (P < 0.001. Conclusions: This study has shown highest specificity for these three classical symptoms in diagnosing diabetes, but these symptoms were insensitive to detect all diabetic subjects.

  17. New polymorphic tetranucleotide microsatellites improve scoring accuracy in the bottlenose dolphin Tursiops aduncus

    NARCIS (Netherlands)

    Nater, Alexander; Kopps, Anna M.; Kruetzen, Michael

    2009-01-01

    We isolated and characterized 19 novel tetranucleotide microsatellite markers in the Indo-Pacific bottlenose dolphin (Tursiops aduncus) in order to improve genotyping accuracy in applications like large-scale population-wide paternity and relatedness assessments. One hundred T. aduncus from Shark Ba

  18. New polymorphic tetranucleotide microsatellites improve scoring accuracy in the bottlenose dolphin Tursiops aduncus

    NARCIS (Netherlands)

    Nater, Alexander; Kopps, Anna M.; Kruetzen, Michael

    We isolated and characterized 19 novel tetranucleotide microsatellite markers in the Indo-Pacific bottlenose dolphin (Tursiops aduncus) in order to improve genotyping accuracy in applications like large-scale population-wide paternity and relatedness assessments. One hundred T. aduncus from Shark

  19. Compact, High Accuracy CO2 Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovative Research Phase II proposal seeks to develop a low cost, robust, highly precise and accurate CO2 monitoring system. This system will...

  20. Compact, High Accuracy CO2 Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovative Research Phase I proposal seeks to develop a low cost, robust, highly precise and accurate CO2 monitoring system. This system will...

  1. High speed high dynamic range high accuracy measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Deibele, Craig E.; Curry, Douglas E.; Dickson, Richard W.; Xie, Zaipeng

    2016-11-29

    A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

  2. Accuracy of the ABC/2 score for intracerebral hemorrhage: Systematic review and analysis of MISTIE, CLEAR-IVH, CLEAR III

    Science.gov (United States)

    Webb, Alastair JS; Ullman, Natalie L; Morgan, Tim C; Muschelli, John; Kornbluth, Joshua; Awad, Issam A; Mayo, Stephen; Rosenblum, Michael; Ziai, Wendy; Zuccarrello, Mario; Aldrich, Francois; John, Sayona; Harnof, Sagi; Lopez, George; Broaddus, William C; Wijman, Christine; Vespa, Paul; Bullock, Ross; Haines, Stephen J; Cruz-Flores, Salvador; Tuhrim, Stan; Hill, Michael D; Narayan, Raj; Hanley, Daniel F

    2015-01-01

    Background and Purpose The ABC/2 score estimates intracerebral hemorrhage (ICH) volume, yet validations have been limited by small samples and inappropriate outcome measures. We determined accuracy of the ABC/2 score calculated at a specialized Reading Center (RC-ABC) or local site (site-ABC) versus the reference-standard CT-based planimetry (CTP). Methods In MISTIE-II, CLEAR-IVH and CLEAR-III trials, ICH volume was prospectively calculated by CTP, RC-ABC and site-ABC. Agreement between CTP and ABC/2 was defined as an absolute difference up to 5ml and relative difference within 20%. Determinants of ABC/2 accuracy were assessed by logistic regression. Results In 4369 scans from 507 patients, CTP was more strongly correlated with RC-ABC (r2=0.93) than site-ABC (r2=0.87). Although RC-ABC overestimated CTP-based volume on average (RC-ABC=15.2cm3, CTP=12.7cm3), agreement was reasonable when categorised into mild, moderate and severe ICH (kappa 0.75, p<0.001). This was consistent with overestimation of ICH volume in 6/8 previous studies. Agreement with CTP was greater for RC-ABC (84% within 5ml; 48% of scans within 20%) than for site-ABC (81% within 5ml; 41% within 20%). RC-ABC had moderate accuracy for detecting ≥ 5ml change in CTP volume between consecutive scans (sensitivity 0.76, specificity 0.86) and was more accurate with smaller ICH, thalamic haemorrhage and homogeneous clots. Conclusions ABC/2 scores at local or central sites are sufficiently accurate to categorise ICH volume and assess eligibility for the CLEAR III and MISTIE III studies, and moderately accurate for change in ICH volume. However, accuracy decreases with large, irregular or lobar clots. Clinical Trial Registration MISTIE-II NCT00224770; CLEAR-III NCT00784134; www.clinicaltrials.gov PMID:26243227

  3. Bayesian estimation of the accuracy of the calf respiratory scoring chart and ultrasonography for the diagnosis of bovine respiratory disease in pre-weaned dairy calves.

    Science.gov (United States)

    Buczinski, Sébastien; L Ollivett, Terri; Dendukuri, Nandini

    2015-05-01

    There is currently no gold standard method for the diagnosis of bovine respiratory disease (BRD) complex in Holstein pre-weaned dairy calves. Systematic thoracic ultrasonography (TUS) has been used as a proxy for BRD, but cannot be directly used by producers. The Wisconsin calf respiratory scoring chart (CRSC) is a simpler alternative, but with unknown accuracy. Our objective was to estimate the accuracy of CRSC, while adjusting for the lack of a gold standard. Two cross sectional study populations with a high BRD prevalence (n=106 pre-weaned Holstein calves) and an average BRD prevalence (n=85 pre-weaned Holstein calves) from North America were studied. All calves were simultaneously assessed using CRSC (cutoff used ≥ 5) and TUS (cutoff used ≥ 1cm of lung consolidation). Bayesian latent class models allowing for conditional dependence were used with informative priors for BRD prevalence and TUS accuracy (sensitivity (Se) and specificity (Sp)) and non-informative priors for CRSC accuracies. Robustness of the model was tested by relaxing priors for prevalence or TUS accuracy. The SeCRSC (95% credible interval (CI)) and SpCRSC were 62.4% (47.9-75.8) and 74.1% (64.9-82.8) respectively. The SeTUS was 79.4% (66.4-90.9) and SpTUS was 93.9% (88.0-97.6). The imperfect accuracy of CRSC and TUS should be taken into account when using those tools to assess BRD status.

  4. High accuracy in silico sulfotransferase models.

    Science.gov (United States)

    Cook, Ian; Wang, Ting; Falany, Charles N; Leyh, Thomas S

    2013-11-29

    Predicting enzymatic behavior in silico is an integral part of our efforts to understand biology. Hundreds of millions of compounds lie in targeted in silico libraries waiting for their metabolic potential to be discovered. In silico "enzymes" capable of accurately determining whether compounds can inhibit or react is often the missing piece in this endeavor. This problem has now been solved for the cytosolic sulfotransferases (SULTs). SULTs regulate the bioactivities of thousands of compounds--endogenous metabolites, drugs and other xenobiotics--by transferring the sulfuryl moiety (SO3) from 3'-phosphoadenosine 5'-phosphosulfate to the hydroxyls and primary amines of these acceptors. SULT1A1 and 2A1 catalyze the majority of sulfation that occurs during human Phase II metabolism. Here, recent insights into the structure and dynamics of SULT binding and reactivity are incorporated into in silico models of 1A1 and 2A1 that are used to identify substrates and inhibitors in a structurally diverse set of 1,455 high value compounds: the FDA-approved small molecule drugs. The SULT1A1 models predict 76 substrates. Of these, 53 were known substrates. Of the remaining 23, 21 were tested, and all were sulfated. The SULT2A1 models predict 22 substrates, 14 of which are known substrates. Of the remaining 8, 4 were tested, and all are substrates. The models proved to be 100% accurate in identifying substrates and made no false predictions at Kd thresholds of 100 μM. In total, 23 "new" drug substrates were identified, and new linkages to drug inhibitors are predicted. It now appears to be possible to accurately predict Phase II sulfonation in silico.

  5. High accuracy & long timescale light curves

    Directory of Open Access Journals (Sweden)

    Hodgkin S.

    2013-04-01

    Full Text Available We present a theoretical analysis of the optical light curves (LCs for short-period high-mass transiting extrasolar planet systems. Our method considers the primary transit, the secondary eclipse, and the overall phase shape of the LC between the occultations. Phase variations arise from (i reflected and thermally emitted light by the planet, (ii the ellipsoidal shape of the star due to the gravitational pull of the planet, and (iii the Doppler shift of the stellar light as the star orbits the center of mass of the system. Our full model of the out-of-eclipse variations contains information about the planetary mass, orbital eccentricity, the orientation of periastron and the planet's albedo. For a range of hypothetical systems we demonstrate that the ellipsoidal variations (ii. can be large enough to be distinguished from the remaining components and that this effect can be used to constrain the planet's mass. As an example we presend KOI-13b (candidate exoplanet system included in the September 2011 Kepler data release. The Kepler light curve shows both primary and secondary eclipses, as well as significant out-of-eclipse light curve variations. We model the relative contributions from (i thermal emission from the companion, (ii planetary reflected light, (iii doppler beaming, and (iv ellipsoidal variations in the host-star arising from the tidal distortion of the host star by its companion. Our analysis, based on the light curve alone, enables us to constrain the mass of the KOI-13.01 companion to be MC = 8.3 ± 1.25 MJ and thus demonstrates that the transiting companion is a planet. The teqnique is useful for current and future space missions such as Kepler and PLATO.

  6. Surgical resident learning styles: faculty and resident accuracy at identification of preferences and impact on ABSITE scores.

    Science.gov (United States)

    Kim, Roger H; Gilbert, Timothy; Ristig, Kyle; Chu, Quyen D

    2013-09-01

    As a consequence of surgical resident duty hour restrictions, there is a need for faculty to utilize novel teaching methods to convey information in a more efficient manner. The current paradigm of surgical training, which has not changed significantly since the time of Halsted, assumes that all residents assimilate information in a similar fashion. However, recent data has shown that learners have preferences for the ways in which they receive and process information. The VARK model categorizes learners as visual (V), aural (A), read/write (R), and kinesthetic (K). The VARK learning style preferences of surgical residents have not been previously evaluated. In this study, the preferred learning styles of general surgery residents were determined, along with faculty and resident perception of resident learning styles. In addition, we hypothesized that American Board of Surgery In-Training Exam (ABSITE) scores are associated with preference for a read/write (R) learning style. The Fleming VARK learning styles inventory was administered to all general surgery residents at a university hospital-based program. Responses on the inventory were scored to determine the preferred learning style for each resident. Faculty members were surveyed to determine their accuracy in identifying the preferred learning style of each resident. All residents were also surveyed to determine their accuracy in identifying their peers' VARK preferences. Resident ABSITE scores were examined for association with preferred learning styles. Twenty-nine residents completed the inventory. Most (18 of 29, 62%) had a multimodal preference, although more than a third (11 of 29, 38%) demonstrated a single-modality preference. Seventy-six percent of all residents (22 of 29) had some degree of kinesthetic (K) learning, while under 50% (14 of 29) were aural (A) learners. Although not significant, dominant (R) learners had the highest mean ABSITE scores. Faculty identified residents' learning styles

  7. Effects of random study checks and guided notes study cards on middle school special education students' notetaking accuracy and science vocabulary quiz scores

    Science.gov (United States)

    Wood, Charles L.

    Federal legislation mandates that all students with disabilities have meaningful access to the general education curriculum and that students with and without disabilities be held equally accountable to the same academic standards (IDEIA, 2004; NCLB, 2001). Many students with disabilities, however, perform poorly in academic content courses, especially at the middle and secondary school levels. Previous research has reported increased notetaking accuracy and quiz scores over lecture content when students completed guided notes compared to taking their own notes. This study evaluated the effects of a pre-quiz review procedure and specially formatted guided notes on middle school special education students' learning of science vocabulary. This study compared the effects of three experimental conditions. (a) Own Notes (ON), (b) Own Notes+Random Study Checks (ON+RSC), and (c) Guided Notes Study Cards+Random Study Checks (GNSC+RSC) on each student's accuracy of notes, next-day quiz scores, and review quiz scores. Each session, the teacher presented 12 science vocabulary terms and definitions during a lecture and students took notes. The students were given 5 minutes to study their notes at the end of each session and were reminded to study their notes at home and in study hall period. In the ON condition students took notes on a sheet of paper with numbered lines from 1 to 12. Just before each next-day quiz in the ON+RSC condition students used write-on response cards to answer two teacher-posed questions over randomly selected vocabulary terms from the previous day's lecture. If the answer on a randomly selected student's response card was correct, that student earned a lottery ticket for inexpensive prizes and a quiz bonus point for herself and each classmate. In the GNSC+RSC condition students took notes on specially formatted guided notes that after the lecture they cut into a set of flashcards that could used for study. The students' mean notetaking accuracy was 75

  8. High accuracy autonomous navigation using the global positioning system (GPS)

    Science.gov (United States)

    Truong, Son H.; Hart, Roger C.; Shoan, Wendy C.; Wood, Terri; Long, Anne C.; Oza, Dipak H.; Lee, Taesul

    1997-01-01

    The application of global positioning system (GPS) technology to the improvement of the accuracy and economy of spacecraft navigation, is reported. High-accuracy autonomous navigation algorithms are currently being qualified in conjunction with the GPS attitude determination flyer (GADFLY) experiment for the small satellite technology initiative Lewis spacecraft. Preflight performance assessments indicated that these algorithms are able to provide a real time total position accuracy of better than 10 m and a velocity accuracy of better than 0.01 m/s, with selective availability at typical levels. It is expected that the position accuracy will be increased to 2 m if corrections are provided by the GPS wide area augmentation system.

  9. Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units.

    Science.gov (United States)

    Cai, Qingzhong; Yang, Gongliu; Song, Ningfang; Liu, Yiliang

    2016-06-22

    An inertial navigation system (INS) has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 × 10(-6)°/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs) using common turntables, has a great application potential in future atomic gyro INSs.

  10. Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units

    Directory of Open Access Journals (Sweden)

    Qingzhong Cai

    2016-06-01

    Full Text Available An inertial navigation system (INS has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 × 10−6°/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs using common turntables, has a great application potential in future atomic gyro INSs.

  11. Absolute binding free energy calculations: on the accuracy of computational scoring of protein-ligand interactions.

    Science.gov (United States)

    Singh, Nidhi; Warshel, Arieh

    2010-05-15

    Calculating the absolute binding free energies is a challenging task. Reliable estimates of binding free energies should provide a guide for rational drug design. It should also provide us with deeper understanding of the correlation between protein structure and its function. Further applications may include identifying novel molecular scaffolds and optimizing lead compounds in computer-aided drug design. Available options to evaluate the absolute binding free energies range from the rigorous but expensive free energy perturbation to the microscopic linear response approximation (LRA/beta version) and related approaches including the linear interaction energy (LIE) to the more approximated and considerably faster scaled protein dipoles Langevin dipoles (PDLD/S-LRA version) as well as the less rigorous molecular mechanics Poisson-Boltzmann/surface area (MM/PBSA) and generalized born/surface area (MM/GBSA) to the less accurate scoring functions. There is a need for an assessment of the performance of different approaches in terms of computer time and reliability. We present a comparative study of the LRA/beta, the LIE, the PDLD/S-LRA/beta, and the more widely used MM/PBSA and assess their abilities to estimate the absolute binding energies. The LRA and LIE methods perform reasonably well but require specialized parameterization for the nonelectrostatic term. The PDLD/S-LRA/beta performs effectively without the need of reparameterization. Our assessment of the MM/PBSA is less optimistic. This approach appears to provide erroneous estimates of the absolute binding energies because of its incorrect entropies and the problematic treatment of electrostatic energies. Overall, the PDLD/S-LRA/beta appears to offer an appealing option for the final stages of massive screening approaches.

  12. Impact of Scoring Single or Multiple Occlusal Lesions on Estimates of Diagnostic Accuracy of the Visual ICDAS-II System

    Directory of Open Access Journals (Sweden)

    Anahita Jablonski-Momeni

    2009-01-01

    differ in appearance and severity. This study aimed to evaluate how estimates of reproducibility and accuracy of ICDAS-II were affected when all lesions on occlusal surfaces, or only a representative lesion, were scored. 100 permanent teeth with 1–4 investigation sites on the occlusal surface were examined visually by four examiners. Serial sections of the teeth were assessed for lesion depth. Intra- and interexaminer reproducibility (weighted kappa values, sensitivity, and specificity were calculated for all investigation sites and for a randomly selected site per tooth. Comparing the kappa values for the whole sample and the independent sites, no effect or only a small effect was found. Comparing the areas under the ROC-curves no effect could be shown. Examining multiple sites on teeth leads to results comparable to when a single independent site is chosen per tooth.

  13. High Accuracy Wavelength Calibration For A Scanning Visible Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Filippo Scotti and Ronald Bell

    2010-07-29

    Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤ 0.2Â. An automated calibration for a scanning spectrometer has been developed to achieve a high wavelength accuracy overr the visible spectrum, stable over time and environmental conditions, without the need to recalibrate after each grating movement. The method fits all relevant spectrometer paraameters using multiple calibration spectra. With a steping-motor controlled sine-drive, accuracies of ~0.025 Â have been demonstrated. With the addition of high resolution (0.075 aresec) optical encoder on the grading stage, greater precision (~0.005 Â) is possible, allowing absolute velocity measurements with ~0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

  14. Influence of spatial temperature distribution on high accuracy interferometric metrology

    Science.gov (United States)

    Gu, Yongqiang; Miao, Erlong; Yan, Feng; Zhang, Jian; Yang, Huaijiang

    2010-10-01

    We calculate the influence of temperature change on the refractive index of air, establish a model of air temperature distribution and analyze the effect of different temperature distribution on the high accuracy interferometric metrology. First, a revised Edlen formula is employed to acquire the relation between temperature and refractive index of air, followed by introducing the fixed temperature gradient distribution among the spatial grid within the optical cavity between the reference flat and the test flat of the Fizeau interferometer, accompanied by a temperature change random function within each grid. Finally, all the rays through the air layer with different incident angles are traced by Matlab program in order to obtain the final output position, angle and OPD for each ray. The influence of different temperature distribution and the length of the optical cavity in on the testing accuracy can be analyzed through the RMS value that results from repeatable rays tracing. As a result, the horizontal distribution (vertical to optical axis) has a large effect on the testing accuracy. Thus, to realize the high accuracy figure metrology, the horizontal distribution of temperature must be rigorously controlled as well as to shorten the length of the optical cavity to a large extent. The results from our simulation are of great significant for the accuracy analysis of interferometric testing and the research of manufacturing a interferometer.

  15. Diagnostic accuracy of the Barr and Blethyn radiological scoring systems for childhood constipation assessed using colonic transit time as the gold standard

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Claire R.; Wylie, Anna B.Z.; Adams, Charlotte [Royal Victoria Infirmary, Department of Paediatric Surgery, Newcastle upon Tyne (United Kingdom); Lee, Richard E. [Royal Victoria Infirmary, Department of Radiology, Newcastle upon Tyne (United Kingdom); Jaffray, Bruce [University of Newcastle upon Tyne, School of Clinical Medical Sciences (Child Health), Sir James Spence Institute, Newcastle upon Tyne (United Kingdom)

    2009-07-15

    Constipation is a common childhood symptom and abdominal radiography is advocated in diagnosis and management. To assess the reproducibility and diagnostic accuracy of the Barr and Blethyn systems for quantifying constipation on abdominal radiographs in children. Radiographs were scored by three observers of increasing radiological experience (student, junior doctor, consultant). Abdominal radiographs produced during measurement of colonic transit time (CTT) were classified as constipated or normal based on the value of the transit time, and were scored using both systems by observers blinded to the CTT. Abdominal radiographs obtained in children for reasons other than constipation were classed as normal and similarly scored. Reproducibility was measured using the kappa statistic. Diagnostic accuracy was measured using the area under the curve (AUC) for the receiver operator characteristic (ROC) curve. Using either system, scores were higher for constipated children (P<0.01). The consultant produced higher scores than the other observers (P<0.01). Interobserver reproducibility was moderate with the best kappa value only 0.48. The best correlation between score and CTT was 0.51 (junior doctor scores). Diagnostic accuracy of the scores was only moderate, with the largest AUC for a ROC curve of 0.84 for the consultant using the Barr score. Scoring of abdominal radiographs in the assessment of childhood constipation should be abandoned because it is dependent on the experience of the observer, is poorly reproducible, and does not accurately discriminate between constipated children and children without constipation. (orig.)

  16. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1998-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with realtime information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate flight

  17. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1999-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with real-time information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate lligh

  18. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1999-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with real-time information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate lligh

  19. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1998-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with realtime information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate flight

  20. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1999-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with real-time information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate

  1. Comprehensive evaluation of ten docking programs on a diverse set of protein-ligand complexes: the prediction accuracy of sampling power and scoring power.

    Science.gov (United States)

    Wang, Zhe; Sun, Huiyong; Yao, Xiaojun; Li, Dan; Xu, Lei; Li, Youyong; Tian, Sheng; Hou, Tingjun

    2016-05-14

    As one of the most popular computational approaches in modern structure-based drug design, molecular docking can be used not only to identify the correct conformation of a ligand within the target binding pocket but also to estimate the strength of the interaction between a target and a ligand. Nowadays, as a variety of docking programs are available for the scientific community, a comprehensive understanding of the advantages and limitations of each docking program is fundamentally important to conduct more reasonable docking studies and docking-based virtual screening. In the present study, based on an extensive dataset of 2002 protein-ligand complexes from the PDBbind database (version 2014), the performance of ten docking programs, including five commercial programs (LigandFit, Glide, GOLD, MOE Dock, and Surflex-Dock) and five academic programs (AutoDock, AutoDock Vina, LeDock, rDock, and UCSF DOCK), was systematically evaluated by examining the accuracies of binding pose prediction (sampling power) and binding affinity estimation (scoring power). Our results showed that GOLD and LeDock had the best sampling power (GOLD: 59.8% accuracy for the top scored poses; LeDock: 80.8% accuracy for the best poses) and AutoDock Vina had the best scoring power (rp/rs of 0.564/0.580 and 0.569/0.584 for the top scored poses and best poses), suggesting that the commercial programs did not show the expected better performance than the academic ones. Overall, the ligand binding poses could be identified in most cases by the evaluated docking programs but the ranks of the binding affinities for the entire dataset could not be well predicted by most docking programs. However, for some types of protein families, relatively high linear correlations between docking scores and experimental binding affinities could be achieved. To our knowledge, this study has been the most extensive evaluation of popular molecular docking programs in the last five years. It is expected that our work

  2. High Test Scores: The Wrong Road to National Economic Success

    Science.gov (United States)

    Baker, Keith

    2011-01-01

    A widely held view is that good schools are essential to a nation's international economic success and that high test scores on international tests of academic skills and knowledge indicate how good a nation's schools are. The widespread belief that good schools are an important contributor to a nation's economic success in the world is supported…

  3. High Test Scores: The Wrong Road to National Economic Success

    Science.gov (United States)

    Baker, Keith

    2011-01-01

    A widely held view is that good schools are essential to a nation's international economic success and that high test scores on international tests of academic skills and knowledge indicate how good a nation's schools are. The widespread belief that good schools are an important contributor to a nation's economic success in the world is supported…

  4. High School Exit Exam Scores and University Performance

    Science.gov (United States)

    D'Agostino, Jerome V.; Bonner, Sarah M.

    2009-01-01

    Many U.S. students must pass a standards-based exit exam to earn a high school diploma. The degree to which exit exams and state standards properly signal to students their preparedness for postsecondary schooling has been questioned. The alignment of test scores with college grades for students at the University of Arizona (n = 2,667) who took…

  5. Compensation of motion error in a high accuracy AFM

    Science.gov (United States)

    Cui, Yuguo; Arai, Yoshikazu; He, Gaofa; Asai, Takemi; Gao, Wei

    2008-10-01

    An atomic force microscope (AFM) system is used for large-area measurement with a spiral scanning strategy, which is composed of an air slide, an air spindle and a probe unit. The motion error which is brought from the air slide and the air spindle will increase with the increasing of the measurement area. Then the measurement accuracy will decrease. In order to achieve a high speed and high accuracy measurement, the probe scans along X-direction with constant height mode driven by the air slide, and at the same time, based on the change way of the motion error, it moves along Zdirection conducted by piezoactuator. According to the above method of error compensation, the profile measurement experiment of a micro-structured surface has been carried out. The experimental result shows that this method is effective for eliminating motion error, and it can achieve high speed and precision measurement of micro-structured surface.

  6. The use of low density high accuracy (LDHA) data for correction of high density low accuracy (HDLA) point cloud

    Science.gov (United States)

    Rak, Michal Bartosz; Wozniak, Adam; Mayer, J. R. R.

    2016-06-01

    Coordinate measuring techniques rely on computer processing of coordinate values of points gathered from physical surfaces using contact or non-contact methods. Contact measurements are characterized by low density and high accuracy. On the other hand optical methods gather high density data of the whole object in a short time but with accuracy at least one order of magnitude lower than for contact measurements. Thus the drawback of contact methods is low density of data, while for non-contact methods it is low accuracy. In this paper a method for fusion of data from two measurements of fundamentally different nature: high density low accuracy (HDLA) and low density high accuracy (LDHA) is presented to overcome the limitations of both measuring methods. In the proposed method the concept of virtual markers is used to find a representation of pairs of corresponding characteristic points in both sets of data. In each pair the coordinates of the point from contact measurements is treated as a reference for the corresponding point from non-contact measurement. Transformation enabling displacement of characteristic points from optical measurement to their match from contact measurements is determined and applied to the whole point cloud. The efficiency of the proposed algorithm was evaluated by comparison with data from a coordinate measuring machine (CMM). Three surfaces were used for this evaluation: plane, turbine blade and engine cover. For the planar surface the achieved improvement was of around 200 μm. Similar results were obtained for the turbine blade but for the engine cover the improvement was smaller. For both freeform surfaces the improvement was higher for raw data than for data after creation of mesh of triangles.

  7. Accuracy Enhancement of Inertial Sensors Utilizing High Resolution Spectral Analysis

    Directory of Open Access Journals (Sweden)

    Michael Korenberg

    2012-08-01

    Full Text Available In both military and civilian applications, the inertial navigation system (INS and the global positioning system (GPS are two complementary technologies that can be integrated to provide reliable positioning and navigation information for land vehicles. The accuracy enhancement of INS sensors and the integration of INS with GPS are the subjects of widespread research. Wavelet de-noising of INS sensors has had limited success in removing the long-term (low-frequency inertial sensor errors. The primary objective of this research is to develop a novel inertial sensor accuracy enhancement technique that can remove both short-term and long-term error components from inertial sensor measurements prior to INS mechanization and INS/GPS integration. A high resolution spectral analysis technique called the fast orthogonal search (FOS algorithm is used to accurately model the low frequency range of the spectrum, which includes the vehicle motion dynamics and inertial sensor errors. FOS models the spectral components with the most energy first and uses an adaptive threshold to stop adding frequency terms when fitting a term does not reduce the mean squared error more than fitting white noise. The proposed method was developed, tested and validated through road test experiments involving both low-end tactical grade and low cost MEMS-based inertial systems. The results demonstrate that in most cases the position accuracy during GPS outages using FOS de-noised data is superior to the position accuracy using wavelet de-noising.

  8. Why is a high accuracy needed in dosimetry. [Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lanzl, L.H.

    1976-01-01

    Dose and exposure intercomparisons on a national or international basis have become an important component of quality assurance in the practice of good radiotherapy. A high degree of accuracy of ..gamma.. and x radiation dosimetry is essential in our international society, where medical information is so readily exchanged and used. The value of accurate dosimetry lies mainly in the avoidance of complications in normal tissue and an optimal degree of tumor control.

  9. Navigation message designing with high accuracy for NAV

    Institute of Scientific and Technical Information of China (English)

    Wang Luxiao; Huang Zhigang; Zhao Yun

    2014-01-01

    Navigation message designing with high accuracy guarantee is the key to efficient navi-gation message distribution in the global navigation satellite system (GNSS). Developing high accu-racy-aware navigation message designing algorithms is an important topic. This paper investigates the high-accuracy navigation message designing problem with the message structure unchanged. The contributions made in this paper include a heuristic that employs the concept of the estimated range deviation (ERD) to improve the existing well-known navigation message on L1 frequency (NAV) of global positioning system (GPS) for good accuracy service; a numerical analysis approximation method (NAAM) to evaluate the range error due to truncation (RET) of different navigation messages; and a basic positioning parameters designing algorithm in the limited space allocation. Based on the predicted ultra-rapid data from the ultra-rapid data from the international GPS service for geodynamic (IGU), ERDs are generated in real time for error correction. Simulations show that the algorithms developed in this paper are general and flexible, and thus are applicable to NAV improvement and other navigation message designs.

  10. High Accuracy, Miniature Pressure Sensor for Very High Temperatures Project

    Data.gov (United States)

    National Aeronautics and Space Administration — SiWave proposes to develop a compact, low-cost MEMS-based pressure sensor for very high temperatures and low pressures in hypersonic wind tunnels. Most currently...

  11. High Accuracy Monocular SFM and Scale Correction for Autonomous Driving.

    Science.gov (United States)

    Song, Shiyu; Chandraker, Manmohan; Guest, Clark C

    2016-04-01

    We present a real-time monocular visual odometry system that achieves high accuracy in real-world autonomous driving applications. First, we demonstrate robust monocular SFM that exploits multithreading to handle driving scenes with large motions and rapidly changing imagery. To correct for scale drift, we use known height of the camera from the ground plane. Our second contribution is a novel data-driven mechanism for cue combination that allows highly accurate ground plane estimation by adapting observation covariances of multiple cues, such as sparse feature matching and dense inter-frame stereo, based on their relative confidences inferred from visual data on a per-frame basis. Finally, we demonstrate extensive benchmark performance and comparisons on the challenging KITTI dataset, achieving accuracy comparable to stereo and exceeding prior monocular systems. Our SFM system is optimized to output pose within 50 ms in the worst case, while average case operation is over 30 fps. Our framework also significantly boosts the accuracy of applications like object localization that rely on the ground plane.

  12. High accuracy and visibility-consistent dense multiview stereo.

    Science.gov (United States)

    Vu, Hoang-Hiep; Labatut, Patrick; Pons, Jean-Philippe; Keriven, Renaud

    2012-05-01

    Since the initial comparison of Seitz et al., the accuracy of dense multiview stereovision methods has been increasing steadily. A number of limitations, however, make most of these methods not suitable to outdoor scenes taken under uncontrolled imaging conditions. The present work consists of a complete dense multiview stereo pipeline which circumvents these limitations, being able to handle large-scale scenes without sacrificing accuracy. Highly detailed reconstructions are produced within very reasonable time thanks to two key stages in our pipeline: a minimum s-t cut optimization over an adaptive domain that robustly and efficiently filters a quasidense point cloud from outliers and reconstructs an initial surface by integrating visibility constraints, followed by a mesh-based variational refinement that captures small details, smartly handling photo-consistency, regularization, and adaptive resolution. The pipeline has been tested over a wide range of scenes: from classic compact objects taken in a laboratory setting, to outdoor architectural scenes, landscapes, and cultural heritage sites. The accuracy of its reconstructions has also been measured on the dense multiview benchmark proposed by Strecha et al., showing the results to compare more than favorably with the current state-of-the-art methods.

  13. Novel method for high accuracy figure measurement of optical flat

    Science.gov (United States)

    E, Kewei; Li, Dahai; Yang, Lijie; Guo, Guangrao; Li, Mengyang; Wang, Xuemin; Zhang, Tao; Xiong, Zhao

    2017-01-01

    Phase Measuring Deflectometry (PMD) is a non-contact, high dynamic-range and full-field metrology which becomes a serious competitor to interferometry. However, the accuracy of deflectometry metrology is strongly influenced by the level of the calibrations, including test geometry, imaging pin-hole camera and digital display. In this paper, we propose a novel method that can measure optical flat surface figure to a high accuracy. We first calibrate the camera using a checker pattern shown on a LCD display at six different orientations, and the last orientation is aligned at the same position as the test optical flat. By using this method, lens distortions and the mapping relationship between the CCD pixels and the subaperture coordinates on the test optical flat can be determined at the same time. To further reduce the influence of the calibration errors on measurements, a reference optical flat with a high quality surface is measured, and then the system errors in our PMD setup can be eliminated by subtracting the figure of the reference flat from the figure of the test flat. Although any expensive coordinates measuring machine, such as laser tracker and coordinates measuring machine are not applied in our measurement, our experimental results of optical flat figure from low to high order aberrations still show a good agreement with that from the Fizeau interferometer.

  14. Differential Predictive Validity of High School GPA and College Entrance Test Scores for University Students in Yemen

    Science.gov (United States)

    Al-Hattami, Abdulghani Ali Dawod

    2012-01-01

    High school grade point average and college entrance test scores are two admission criteria that are currently used by most colleges in Yemen to select their prospective students. Given their widespread use, it is important to investigate their predictive validity to ensure the accuracy of the admission decisions in these institutions. This study…

  15. Differential Predictive Validity of High School GPA and College Entrance Test Scores for University Students in Yemen

    Science.gov (United States)

    Al-Hattami, Abdulghani Ali Dawod

    2012-01-01

    High school grade point average and college entrance test scores are two admission criteria that are currently used by most colleges in Yemen to select their prospective students. Given their widespread use, it is important to investigate their predictive validity to ensure the accuracy of the admission decisions in these institutions. This study…

  16. High Accuracy Near-infrared Imaging Polarimetry with NICMOS

    CERN Document Server

    Batcheldor, D; Hines, D C; Schmidt, G D; Axon, D J; Robinson, A; Sparks, W; Tadhunter, C

    2008-01-01

    The findings of a nine orbit calibration plan carried out during HST Cycle 15, to fully determine the NICMOS camera 2 (2.0 micron) polarization calibration to high accuracy, are reported. Recently Ueta et al. and Batcheldor et al. have suggested that NICMOS possesses a residual instrumental polarization at a level of 1.2-1.5%. This would completely inhibit the data reduction in a number of GO programs, and hamper the ability of the instrument to perform high accuracy polarimetry. We obtained polarimetric calibration observations of three polarimetric standards at three spacecraft roll angles separated by ~60deg. Combined with archival data, these observations were used to characterize the residual instrumental polarization in order for NICMOS to reach its full potential of accurate imaging polarimetry at p~1%. Using these data, we place an 0.6% upper limit on the instrumental polarization and calculate values of the parallel transmission coefficients that reproduce the ground-based results for the polarimetri...

  17. High-accuracy mass spectrometry for fundamental studies.

    Science.gov (United States)

    Kluge, H-Jürgen

    2010-01-01

    Mass spectrometry for fundamental studies in metrology and atomic, nuclear and particle physics requires extreme sensitivity and efficiency as well as ultimate resolving power and accuracy. An overview will be given on the global status of high-accuracy mass spectrometry for fundamental physics and metrology. Three quite different examples of modern mass spectrometric experiments in physics are presented: (i) the retardation spectrometer KATRIN at the Forschungszentrum Karlsruhe, employing electrostatic filtering in combination with magnetic-adiabatic collimation-the biggest mass spectrometer for determining the smallest mass, i.e. the mass of the electron anti-neutrino, (ii) the Experimental Cooler-Storage Ring at GSI-a mass spectrometer of medium size, relative to other accelerators, for determining medium-heavy masses and (iii) the Penning trap facility, SHIPTRAP, at GSI-the smallest mass spectrometer for determining the heaviest masses, those of super-heavy elements. Finally, a short view into the future will address the GSI project HITRAP at GSI for fundamental studies with highly-charged ions.

  18. Researches on High Accuracy Prediction Methods of Earth Orientation Parameters

    Science.gov (United States)

    Xu, X. Q.

    2015-09-01

    The Earth rotation reflects the coupling process among the solid Earth, atmosphere, oceans, mantle, and core of the Earth on multiple spatial and temporal scales. The Earth rotation can be described by the Earth's orientation parameters, which are abbreviated as EOP (mainly including two polar motion components PM_X and PM_Y, and variation in the length of day ΔLOD). The EOP is crucial in the transformation between the terrestrial and celestial reference systems, and has important applications in many areas such as the deep space exploration, satellite precise orbit determination, and astrogeodynamics. However, the EOP products obtained by the space geodetic technologies generally delay by several days to two weeks. The growing demands for modern space navigation make high-accuracy EOP prediction be a worthy topic. This thesis is composed of the following three aspects, for the purpose of improving the EOP forecast accuracy. (1) We analyze the relation between the length of the basic data series and the EOP forecast accuracy, and compare the EOP prediction accuracy for the linear autoregressive (AR) model and the nonlinear artificial neural network (ANN) method by performing the least squares (LS) extrapolations. The results show that the high precision forecast of EOP can be realized by appropriate selection of the basic data series length according to the required time span of EOP prediction: for short-term prediction, the basic data series should be shorter, while for the long-term prediction, the series should be longer. The analysis also showed that the LS+AR model is more suitable for the short-term forecasts, while the LS+ANN model shows the advantages in the medium- and long-term forecasts. (2) We develop for the first time a new method which combines the autoregressive model and Kalman filter (AR+Kalman) in short-term EOP prediction. The equations of observation and state are established using the EOP series and the autoregressive coefficients

  19. Researching the technology of high-accuracy camshaft measurement

    Science.gov (United States)

    Chen, Wei; Chen, Yong-Le; Wang, Hong; Liao, Hai-Yang

    1996-10-01

    This paper states the cam's data processing algorithm in detail in high accurate camshaft measurement system. It contains: 1) using minimum error of curve symmetry to seek the center position of the key slot; 2) Calculating the minimum error by cam's curve in theory to search top area; 3) According to cam's tolerance E(i) function and minimum angle error at cam top, seeking the best position of cam top and getting the best angle value and error curve. The algorithm is suitable for measuring all kinds of symmetry or asymmetry cam, and plain push-rod or spherical push-rod cam, for example, bus camshaft, car camshaft, motor camshaft, etc. Using the algorithm, high accuracy measurement can be achieved.

  20. Read-only high accuracy volume holographic optical correlator

    Science.gov (United States)

    Zhao, Tian; Li, Jingming; Cao, Liangcai; He, Qingsheng; Jin, Guofan

    2011-10-01

    A read-only volume holographic correlator (VHC) is proposed. After the recording of all of the correlation database pages by angular multiplexing, a stand-alone read-only high accuracy VHC will be separated from the VHC recording facilities which include the high-power laser and the angular multiplexing system. The stand-alone VHC has its own low power readout laser and very compact and simple structure. Since there are two lasers that are employed for recording and readout, respectively, the optical alignment tolerance of the laser illumination on the SLM is very sensitive. The twodimensional angular tolerance is analyzed based on the theoretical model of the volume holographic correlator. The experimental demonstration of the proposed read-only VHC is introduced and discussed.

  1. Spatial augmented reality based high accuracy human face projection

    Science.gov (United States)

    Li, Dong; Xie, Jinghui; Li, Yufeng; Weng, Dongdong; Liu, Yue

    2015-08-01

    This paper discusses the imaging principles and the technical difficulties of spatial augmented reality based human face projection. A novel geometry correction method is proposed to realize fast, high-accuracy face model projection. Using a depth camera to reconstruct the projected object, the relative position from the rendered model to the projector can be accessed and the initial projection image is generated. Then the projected image is distorted by using Bezier interpolation to guarantee that the projected texture matches with the object surface. The proposed method is under a simple process flow and can achieve high perception registration of virtual and real object. In addition, this method has a good performance in the condition that the reconstructed model is not exactly same with the rendered virtual model which extends its application area in the spatial augmented reality based human face projection.

  2. High Framingham risk score decreases quality of life in adults

    Directory of Open Access Journals (Sweden)

    Christian Yosaputra

    2010-04-01

    Full Text Available Cardiovascular disease (CVD risk factors, such as diabetes, hypertension, hypercholesterolemia, smoking, and obesity tend to occur together in the general population. Increasing prevalence of multiple CVD risk factors has been related to increased risk of death from coronary heart disease and stroke. Studies have suggested that people with several risk factors of CVD may have impaired health-related quality of life. The objective of this study was to assess the association of CVD risk factors with quality of life (QOL among adults aged 40 to 65 years. A cross-sectional study was conducted involving 220 subjects 40 - 65 years of age at a health center. The CVD risk factors were assessed using the Framingham risk score that is the standard instrument for assessment of the risk of a first cardiac event. The risk factors assessed were age, smoking, blood pressure, total cholesterol and high density lipoprotein cholesterol concentrations. QOL was assessed by means of the WHOQOL-BREF instrument that had been prevalidated. The results of the study showed that 28.2% of subjects were smokers, 56.4% had stage 1 hypertension, 42.8% high total cholesterol and 13.6% low HDL cholesterol. The high risk group amounted to 45.5% and 42.3% constitued an intermediate risk group. High CVD risk scores were significantly associated with a low QOL for all domains (physical, psychological, social and environment (p=0.000. Preventing or reducing the multiple CVD risk factors to improve QOL is necessary among adults.

  3. Predicting Streptococcal Pharyngitis in Adults in Primary Care: A Systematic Review of the Diagnostic Accuracy of Symptoms and Signs and Validation of the Centor Score

    LENUS (Irish Health Repository)

    Aalbers, Jolien

    2011-06-01

    Abstract Background Stratifying patients with a sore throat into the probability of having an underlying bacterial or viral cause may be helpful in targeting antibiotic treatment. We sought to assess the diagnostic accuracy of signs and symptoms and validate a clinical prediction rule (CPR), the Centor score, for predicting group A β-haemolytic streptococcal (GABHS) pharyngitis in adults (> 14 years of age) presenting with sore throat symptoms. Methods A systematic literature search was performed up to July 2010. Studies that assessed the diagnostic accuracy of signs and symptoms and\\/or validated the Centor score were included. For the analysis of the diagnostic accuracy of signs and symptoms and the Centor score, studies were combined using a bivariate random effects model, while for the calibration analysis of the Centor score, a random effects model was used. Results A total of 21 studies incorporating 4,839 patients were included in the meta-analysis on diagnostic accuracy of signs and symptoms. The results were heterogeneous and suggest that individual signs and symptoms generate only small shifts in post-test probability (range positive likelihood ratio (+LR) 1.45-2.33, -LR 0.54-0.72). As a decision rule for considering antibiotic prescribing (score ≥ 3), the Centor score has reasonable specificity (0.82, 95% CI 0.72 to 0.88) and a post-test probability of 12% to 40% based on a prior prevalence of 5% to 20%. Pooled calibration shows no significant difference between the numbers of patients predicted and observed to have GABHS pharyngitis across strata of Centor score (0-1 risk ratio (RR) 0.72, 95% CI 0.49 to 1.06; 2-3 RR 0.93, 95% CI 0.73 to 1.17; 4 RR 1.14, 95% CI 0.95 to 1.37). Conclusions Individual signs and symptoms are not powerful enough to discriminate GABHS pharyngitis from other types of sore throat. The Centor score is a well calibrated CPR for estimating the probability of GABHS pharyngitis. The Centor score can enhance appropriate

  4. Accuracy of prostate biopsies for predicting Gleason score in radical prostatectomy specimens: nationwide trends 2000-2012.

    Science.gov (United States)

    Danneman, Daniela; Drevin, Linda; Delahunt, Brett; Samaratunga, Hemamali; Robinson, David; Bratt, Ola; Loeb, Stacy; Stattin, Pär; Egevad, Lars

    2017-01-01

    To investigate how well the Gleason score in diagnostic needle biopsies predicted the Gleason score in a subsequent radical prostatectomy (RP) specimen before and after the 2005 International Society of Urological Pathology (ISUP) revision of Gleason grading, and if the recently proposed ISUP grades 1-5 (corresponding to Gleason scores 6, 3 + 4, 4 + 3, 8 and 9-10) better predict the RP grade. All prostate cancers diagnosed in Sweden are reported to the National Prostate Cancer Register (NPCR). We analysed the Gleason scores and ISUP grades from the diagnostic biopsies and the RP specimens in 15 598 men in the NPCR who: were diagnosed between 2000 and 2012 with clinical stage T1-2 M0/X prostate cancer on needle biopsy; were aged ≤70 years; had serum PSA concentration of ISUP grades would have led to a decreasing agreement between biopsy and RP grades over time, from 68% in 2000 to 57% in 2012, with an OR of 0.95 in multivariable analysis (P ISUP grading revision. Had ISUP grades been used instead of Gleason score, the agreement between biopsy and RP grade would have decreased, probably because of its separation of Gleason score 7 into ISUP grades 2 and 3 (Gleason score 3 + 4 vs 4 + 3). © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  5. High accuracy mantle convection simulation through modern numerical methods

    KAUST Repository

    Kronbichler, Martin

    2012-08-21

    Numerical simulation of the processes in the Earth\\'s mantle is a key piece in understanding its dynamics, composition, history and interaction with the lithosphere and the Earth\\'s core. However, doing so presents many practical difficulties related to the numerical methods that can accurately represent these processes at relevant scales. This paper presents an overview of the state of the art in algorithms for high-Rayleigh number flows such as those in the Earth\\'s mantle, and discusses their implementation in the Open Source code Aspect (Advanced Solver for Problems in Earth\\'s ConvecTion). Specifically, we show how an interconnected set of methods for adaptive mesh refinement (AMR), higher order spatial and temporal discretizations, advection stabilization and efficient linear solvers can provide high accuracy at a numerical cost unachievable with traditional methods, and how these methods can be designed in a way so that they scale to large numbers of processors on compute clusters. Aspect relies on the numerical software packages deal.II and Trilinos, enabling us to focus on high level code and keeping our implementation compact. We present results from validation tests using widely used benchmarks for our code, as well as scaling results from parallel runs. © 2012 The Authors Geophysical Journal International © 2012 RAS.

  6. Prognostic accuracy of SIRS criteria, qSOFA score and GYM score for 30-day-mortality in older non-severely dependent infected patients attended in the emergency department.

    Science.gov (United States)

    González Del Castillo, J; Julian-Jiménez, A; González-Martínez, F; Álvarez-Manzanares, J; Piñera, P; Navarro-Bustos, C; Martinez-Ortiz de Zarate, M; Llopis-Roca, F; Debán Fernández, M; Gamazo-Del Rio, J; García-Lamberechts, E J; Martín-Sánchez, F J

    2017-07-28

    The aim of this study was to determine the accuracy of systemic inflammatory response syndrome (SIRS), quick Sepsis-related Organ Failure Assessment (qSOFA) score and GYM score to predict 30-day mortality in older non-severely dependent patients attended for an episode of infection in the emergency department (ED). We performed an analytical, observational, prospective cohort study including patients 75 years of age or older, without severe functional dependence, attended for an infectious process in 69 Spanish EDs for 2-day three-seasonal periods. Demographic, clinical and analytical data were collected. The primary outcome was 30-day mortality after the index event. We included 1071 patients, with a mean age of 83.6 [standard deviation (SD) 5.6] years; 544 (50.8%) were men. Seventy-two patients (6.5%) died within 30 days. SIRS criteria ≥ 2 had a sensitivity of 65% [95% confidence interval (CI) 53.1-75.9] and a specificity of 49% (95% CI 46.0-52.3), a qSOFA score ≥ 2 had a sensitivity of 28% (95% CI 18.2-39.8) and a specificity of 94% (95% CI 91.9-95.1), and a GYM score ≥ 1 had a sensitivity of 81% (95% CI 69.2-88.6) and a specificity of 45% (95% CI 41.6-47.9). A GYM score ≥ 1 and a qSOFA score ≥ 2 were the cut-offs with the highest sensitivity (p SIRS. A GYM score ≥ 1 may be the most sensitive score and a qSOFA score ≥ 2 the most specific score to predict 30-day mortality in non-severely dependent older patients attended for acute infection in EDs.

  7. Monitoring techniques for high accuracy interference fit assembly processes

    Science.gov (United States)

    Liuti, A.; Vedugo, F. Rodriguez; Paone, N.; Ungaro, C.

    2016-06-01

    In the automotive industry, there are many assembly processes that require a high geometric accuracy, in the micrometer range; generally open-loop controllers cannot meet these requirements. This results in an increased defect rate and high production costs. This paper presents an experimental study of interference fit process, aimed to evaluate the aspects which have the most impact on the uncertainty in the final positioning. The press-fitting process considered, consists in a press machine operating with a piezoelectric actuator to press a plug into a sleeve. Plug and sleeve are designed and machined to obtain a known interference fit. Differential displacement and velocity measurements of the plug with respect to the sleeve are measured by a fiber optic differential laser Doppler vibrometer. Different driving signals of the piezo actuator allow to have an insight into the differences between a linear and a pulsating press action. The paper highlights how the press-fit assembly process is characterized by two main phases: the first is an elastic deformation of the plug and sleeve, which produces a reversible displacement, the second is a sliding of the plug with respect to the sleeve, which results in an irreversible displacement and finally realizes the assembly. The simultaneous measurements of the displacement and the force have permitted to define characteristic features in the signal useful to identify the start of the irreversible movement. These indicators could be used to develop a control logic in a press assembly process.

  8. A high-accuracy DCO with hybrid architecture

    Science.gov (United States)

    Sun, Yapeng; Zhao, Huidong; Qiao, Shushan; Hei, Yong; Zhang, Fuhai

    2017-07-01

    In this paper, a novel hybrid digital-controlled oscillator (DCO) is proposed, which is used to improve the accuracy of the all-digital clock generator without reference source. The DCO with hybrid architecture consists of two parts: DCO_high and DCO_low. The DCO_high decides the coarse output frequency of DCO, and adopts the cascade structure to decrease the area. The DCO_low adopts the chain structure with three-state buffer, and decides the fine output frequency of DCO. Compared with traditional cascade DCO, the proposed hybrid DCO features higher precision with less inherent delay. Therefore the clock generator can tolerate process, voltage and temperature (PVT) variation and meet the needs of different conditions. The DCO is designed in SMIC 180 nm CMOS process with 0.021 mm2 chip area. The output frequency is adjusted from 15-120 MHz. The frequency error is less than 0.83% at 25 MHz with 1.6-1.8 V supply voltage and 0-80 °C temperature variations in TT, FF, SS corners. Project supported by the National Natural Science Foundation of China (Nos. 61306025, 61474135).

  9. Criteria of GenCall score to edit marker data and methods to handle missing markers have an influence on accuracy of genomic predictions

    DEFF Research Database (Denmark)

    Edriss, Vahid; Guldbrandtsen, Bernt; Lund, Mogens Sandø

    2013-01-01

    contained 1071 Jersey bulls that were genotyped with the Illumina Bovine 50K chip. After preliminary editing, 39227 SNP remained in the dataset. Four methods to handle missing genotypes were: 1) BEAGLE: missing markers were imputed using Beagle 3.3 software, 2) COMMON: missing genotypes at a locus were...... that missing genotypes should be imputed in order to improve genomic prediction. Editing the marker data with stringent threshold on GenCall (GC) scores and then imputing the discarded genotypes did not lead to higher accuracy. All marker genotypes with a GC score over 0.15 should be retained for genomic...

  10. High-resolution CT of nontuberculous mycobacterium infection in adult CF patients: diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    McEvoy, Sinead; Lavelle, Lisa; Kilcoyne, Aoife; McCarthy, Colin; Dodd, Jonathan D. [St. Vincent' s University Hospital, Department of Radiology, Dublin (Ireland); DeJong, Pim A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Loeve, Martine; Tiddens, Harm A.W.M. [Erasmus MC-Sophia Children' s Hospital, Department of Radiology, Department of Pediatric Pulmonology and Allergology, Rotterdam (Netherlands); McKone, Edward; Gallagher, Charles G. [St. Vincent' s University Hospital, Department of Respiratory Medicine and National Referral Centre for Adult Cystic Fibrosis, Dublin (Ireland)

    2012-12-15

    To determine the diagnostic accuracy of high-resolution computed tomography (HRCT) for the detection of nontuberculous mycobacterium infection (NTM) in adult cystic fibrosis (CF) patients. Twenty-seven CF patients with sputum-culture-proven NTM (NTM+) underwent HRCT. An age, gender and spirometrically matched group of 27 CF patients without NTM (NTM-) was included as controls. Images were randomly and blindly analysed by two readers in consensus and scored using a modified Bhalla scoring system. Significant differences were seen between NTM (+) and NTM (-) patients in the severity of the bronchiectasis subscore [45 % (1.8/4) vs. 35 % (1.4/4), P = 0.029], collapse/consolidation subscore [33 % (1.3/3) vs. 15 % (0.6/3)], tree-in-bud/centrilobular nodules subscore [43 % (1.7/3) vs. 25 % (1.0/3), P = 0.002] and the total CT score [56 % (18.4/33) vs. 46 % (15.2/33), P = 0.002]. Binary logistic regression revealed BMI, peribronchial thickening, collapse/consolidation and tree-in-bud/centrilobular nodules to be predictors of NTM status (R{sup 2} = 0.43). Receiver-operator curve analysis of the regression model showed an area under the curve of 0.89, P < 0.0001. In adults with CF, seven or more bronchopulmonary segments showing tree-in-bud/centrilobular nodules on HRCT is highly suggestive of NTM colonisation. (orig.)

  11. Determination of UAV position using high accuracy navigation platform

    Directory of Open Access Journals (Sweden)

    Ireneusz Kubicki

    2016-07-01

    Full Text Available The choice of navigation system for mini UAV is very important because of its application and exploitation, particularly when the installed on it a synthetic aperture radar requires highly precise information about an object’s position. The presented exemplary solution of such a system draws attention to the possible problems associated with the use of appropriate technology, sensors, and devices or with a complete navigation system. The position and spatial orientation errors of the measurement platform influence on the obtained SAR imaging. Both, turbulences and maneuvers performed during flight cause the changes in the position of the airborne object resulting in deterioration or lack of images from SAR. Consequently, it is necessary to perform operations for reducing or eliminating the impact of the sensors’ errors on the UAV position accuracy. You need to look for compromise solutions between newer better technologies and in the field of software. Keywords: navigation systems, unmanned aerial vehicles, sensors integration

  12. Is an Extended Prostate Biopsy Scheme Associated with an Improvement in the Accuracy Between the Biopsy Gleason Score and Radical Prostatectomy Pathology? A Multivariate Analysis.

    Science.gov (United States)

    Zugor, Vahudin; Poth, Sandor; Kühn, Reinhard; Bernat, Marija Maja; Porres, Daniel; Labanaris, Apostolos P

    2016-08-01

    To examine whether an extended prostate biopsy (PB) scheme is associated with an improvement in the accuracy between the PB Gleason score (GS) and radical prostatectomy (RP) pathology and to identify probable preoperative variables that stratified patients likely to harbor significant upgrading (SU). A retrospective review of 538 patients' records diagnosed with prostate cancer (PCa) who underwent RP and exhibited a SU, at two tertiary medical centers, was conducted. The patients were divided into 3 groups: 194 who underwent a 6-core PB (36%), 156 who underwent a 12-core PB (28.9%) and 188 (34.9%) who underwent an 18-core PB. A multivariate analysis was conducted, including prostate-specific antigen (PSA) level, clinical stage, prostate size and duration from PB to RP. The 6-core group exhibited a 42.7% SU, the 12-core group exhibited a 38.8% SU and the 18-core group exhibited a 14.1% SU. There was a highly significant lower rate of SU in the 18-core than that in the 6-core (pmultivariate analysis, only a prostate size of >35 g significantly elevated the probability of SU in the 6-core (p35 g in patients who undergo a 6- or 12-core PB is the only preoperative variable that stratifies patients likely to harbor SU. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  13. Accuracy of J-CTO Score Derived From Computed Tomography Versus Angiography to Predict Successful Percutaneous Coronary Intervention.

    Science.gov (United States)

    Fujino, Akiko; Otsuji, Satoru; Hasegawa, Katsuyuki; Arita, Toyohiro; Takiuchi, Shin; Fujii, Kenichi; Yabuki, Masanori; Ibuki, Motoaki; Nagayama, Shinya; Ishibuchi, Kasumi; Kashiyama, Toshikazu; Ishii, Rui; Tamaru, Hiroto; Yamamoto, Wataru; Hara, Masahiko; Higashino, Yorihiko

    2017-06-14

    The aim of this study was to compare the ability of conventional versus computed tomography angiography (CTA) to predict procedural success and 30-min wire crossing rates in percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) lesions. Coronary CTA can be used to assess the morphology of CTO lesions. We examined 205 consecutive patients (218 CTO lesions) who underwent coronary CTA pre-PCI. The J-CTO (Multicenter CTO Registry of Japan) score (the sum of the following 5 binary parameters: blunt proximal cap, calcification, bending >45°, and length of occluded segment >20 mm plus previously failed PCI attempt) was calculated using both CTA and conventional coronary angiography and compared. The median patient age was 69 years (interquartile range: 62 to 75 years), 82.4% were male, and a retrograde approach was attempted in 72 (33.0%) cases. The procedural success rate of the CTO-PCI procedures was 82.6%, and 29.4% of cases achieved 30-min wire crossing. The areas under the curve of the CTA-derived J-CTO score for predicting procedural success and 30-min wire crossing were significantly greater than those derived from conventional angiography (0.855 vs. 0.698; p CTO score was a more useful predictor of both procedural success and 30-min wire crossing than the J-CTO score derived from conventional angiography. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Rapid, high-accuracy detection of strabismus and amblyopia using the pediatric vision scanner.

    Science.gov (United States)

    Loudon, Sjoukje E; Rook, Caitlin A; Nassif, Deborah S; Piskun, Nadya V; Hunter, David G

    2011-07-07

    Purpose. The Pediatric Vision Scanner (PVS) detects strabismus by identifying ocular fixation in both eyes simultaneously. This study was undertaken to assess the ability of the PVS to identify patients with amblyopia or strabismus, particularly anisometropic amblyopia with no measurable strabismus. Methods. The PVS test, administered from 40 cm and requiring 2.5 seconds of attention, generated a binocularity score (BIN, 0%-100%). We tested 154 patients and 48 controls between the ages of 2 and 18 years. BIN scores of amblyopic children and controls were measured, and 21 children received sequential PVS measurements to detect any changes in BIN resulting from amblyopia treatment. Results. With the pass/refer threshold set at BIN 60%, sensitivity and specificity were 96% for the detection of amblyopia or strabismus. Assuming a 5% prevalence of amblyopia or strabismus, the inferred positive and negative predictive values of the PVS were 56% and 100%, respectively. Fixation accuracy was significantly reduced in amblyopic eyes. In anisometropic amblyopia patients treated successfully, the BIN improved to 100%. Conclusions. The PVS identified children with amblyopia or strabismus with high sensitivity and specificity, while successful treatment restored normal BIN scores in amblyopic patients without strabismus. The results support the hypothesis that the PVS detects strabismus and amblyopia directly. Future strategies for screening by nonspecialists may thus be based on diagnostic detection of amblyopia and strabismus rather than the estimation of risk factors, allowing for rapid, accurate identification of children with amblyopia early in life when it is most amenable to treatment.

  15. Illustration of SSMD, z score, SSMD*, z* score, and t statistic for hit selection in RNAi high-throughput screens.

    Science.gov (United States)

    Zhang, Xiaohua Douglas

    2011-08-01

    Hit selection is the ultimate goal in many high-throughput screens. Various analytic methods are available for this purpose. Some commonly used ones are z score, z* score, strictly standardized mean difference (SSMD), SSMD*, and t statistic. It is critical to know how to use them correctly because the misusage of them can readily produce misleading results. Here, the author presents basic concepts, elaborates their commonality and difference, describes some common misusage that people should avoid, and uses simulated simple examples to illustrate how to use them correctly.

  16. AutoDock Vina: improving the speed and accuracy of docking with a new scoring function, efficient optimization, and multithreading.

    Science.gov (United States)

    Trott, Oleg; Olson, Arthur J

    2010-01-30

    AutoDock Vina, a new program for molecular docking and virtual screening, is presented. AutoDock Vina achieves an approximately two orders of magnitude speed-up compared with the molecular docking software previously developed in our lab (AutoDock 4), while also significantly improving the accuracy of the binding mode predictions, judging by our tests on the training set used in AutoDock 4 development. Further speed-up is achieved from parallelism, by using multithreading on multicore machines. AutoDock Vina automatically calculates the grid maps and clusters the results in a way transparent to the user. Copyright 2009 Wiley Periodicals, Inc.

  17. The Correlational Relationship between Homeschooling Demographics and High Test Scores.

    Science.gov (United States)

    Burns, Johnna

    Homeschooling, one of the fastest growing educational alternatives, is enjoying increasing respect from educators and parents alike. This is partly because homeschooling children score as well and often better on standardized tests than their publicly schooled counterparts. However, the vast majority of homeschooled students come from the…

  18. Housing Costs, Zoning, and Access to High-Scoring Schools

    Science.gov (United States)

    Rothwell, Jonathan

    2012-01-01

    The first section of this paper surveys academic research on educational achievement with an emphasis on the relative effects of schools and families in shaping educational outcomes. A methodology section provides a summary of data sources and defines the main variables measured. The paper then examines differences in school test score performance…

  19. Key technologies for high-accuracy large mesh antenna reflectors

    Science.gov (United States)

    Meguro, Akira; Harada, Satoshi; Watanabe, Mitsunobu

    2003-12-01

    Nippon Telephone and Telegram Corporation (NTT) continues to develop the modular mesh-type deployable antenna. Antenna diameter can be changed from 5 m to about 20 m by changing the number of modules used with surface accuracy better than 2.4 mm RMS (including all error factors) with sufficient deployment reliability. Key technologies are the antenna's structural design, the deployment mechanism, the design tool, the analysis tool, and modularized testing/evaluation methods. This paper describes our beam steering mechanism. Tests show that it yields a beam pointing accuracy of better than 0.1°. Based on the S-band modular mesh antenna reflector, the surface accuracy degradation factors that must be considered in designing the new antenna are partially identified. The influence of modular connection errors on surface accuracy is quantitatively estimated. Our analysis tool SPADE is extended to include the addition of joint gaps. The addition of gaps allows non-linear vibration characteristics due to gapping in deployment hinges to be calculated. We intend to design a new type of mesh antenna reflector. Our new goal is an antenna for Ku or Ka band satellite communication. For this mission, the surface shape must be 5 times more accurate than is required for an S-band antenna.

  20. High Accuracy and Real-Time Gated Viewing Laser Radar

    Institute of Scientific and Technical Information of China (English)

    Dong Li; Hua-Jun Yang; Shan-Pei Zhou

    2011-01-01

    A gated viewing laser radar has an excellent performance in underwater low light level imaging,and it also provides a viable solution to inhibit backscattering.In this paper,a gated viewing imaging system according to the demand for real-time imaging is presented,and then the simulation is used to analyze the performance of the real-time gated viewing system.The range accuracy performance is limited by the slice number,the width of gate,the delay time step,the initial delay time,as well as the system noise and atmospheric turbulence.The simulation results indicate that the highest range accuracy can be achieved when the system works with the optimal parameters.Finally,how to choose the optimal parameters has been researched.

  1. Diagnostic performance of combined elastosonography scoring and high-resolution ultrasonography for the differentiation of benign and malignant thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Shweel, Mohamed, E-mail: mohshweel@yahoo.com [Radiology Department, El Minia University Hospital, El Minia (Egypt); Mansour, Ehab, E-mail: Ehabrad71@yahoo.com [Radiology Department, Assiut University Hospitals, Assiut (Egypt)

    2013-06-15

    Aim: To evaluate the diagnostic performance of the combined use of elstosonography (USE) scoring and high-resolution ultrasonography (HRUS) for the differentiation of benign and malignant thyroid nodule. Patients and methods: Forty-seven consecutive patients with 66 thyroid nodules were enrolled in the present study. Thyroid surgery had been already planned for all the patients. All of them were submitted to high-resolution ultrasonography and elastography scoring at the same sitting. The latter was determined with 5-point scoring method. The examination results were compared against pathological findings as the gold standard of reference. Results: The sensitivity, specificity, accuracy, positive predictive, and negative predictive values of HRUS in the differential diagnosis of thyroid nodules were 92.0%, 72.9%, 60.1%, 95.0%, and 63.1%, respectively, while that of ultrasound elastography scoring were 75.4%, 85.5%, 86.7%, 71.4%, and 90.5%, respectively. Combined use of both US techniques resulted in a higher diagnostic performance as it showed 95.4%, 94.8%, 95.2%, 82.3% and 98.8% sensitivity, specificity, accuracy, positive predictive, and negative predictive values, respectively. Conclusions: The use of combined USE and HRS for the differentiation of benign and malignant thyroid nodules resulted in a high diagnostic performance and a significant statistical difference as compared to HRUS or USE alone (P = 0.003)

  2. High Accuracy Thermal Expansion Measurement at Cryogenic Temperatures

    Science.gov (United States)

    Tucker, Jim; Despit, Gregory; Stallcup, Michael; Presson, Joan; Nein, Max

    2003-01-01

    A new, interferometer-based system for measuring thermal expansion to an absolute accuracy of 20 ppb or better at cryogenic temperatures has been developed. Data from NIST Copper SRM 736 measured from room temperature to 15 K will be presented along with data from many other materials including beryllium, ULE, Zerodur, and composite materials. Particular attention will be given to a study by the Space Optics Manufacturing Technology Center (SOMTC) investigating the variability of ULE and beryllium materials used in the AMSD program Approximately 20 samples of each material, tested from room temperature to below 30 K are compared as a function of billet location.

  3. Design of a high linearity and high gain accuracy analog baseband circuit for DAB receiver

    Science.gov (United States)

    Li, Ma; Zhigong, Wang; Jian, Xu; Yiqiang, Wu; Junliang, Wang; Mi, Tian; Jianping, Chen

    2015-02-01

    An analog baseband circuit of high linearity and high gain accuracy for a digital audio broadcasting receiver is implemented in a 0.18-μm RFCMOS process. The circuit comprises a 3rd-order active-RC complex filter (CF) and a programmable gain amplifier (PGA). An automatic tuning circuit is also designed to tune the CF's pass band. Instead of the class-A fully differential operational amplifier (FDOPA) adopted in the conventional CF and PGA design, a class-AB FDOPA is specially employed in this circuit to achieve a higher linearity and gain accuracy for its large current swing capability with lower static current consumption. In the PGA circuit, a novel DC offset cancellation technique based on the MOS resistor is introduced to reduce the settling time significantly. A reformative switching network is proposed, which can eliminate the switch resistor's influence on the gain accuracy of the PGA. The measurement result shows the gain range of the circuit is 10-50 dB with a 1-dB step size, and the gain accuracy is less than ±0.3 dB. The OIP3 is 23.3 dBm at the gain of 10 dB. Simulation results show that the settling time is reduced from 100 to 1 ms. The image band rejection is about 40 dB. It only draws 4.5 mA current from a 1.8 V supply voltage.

  4. Frequency Comparison of Two High-Accuracy Al+ Optical Clocks

    CERN Document Server

    Chou, C -W; Koelemeij, J C J; Wineland, D J; Rosenband, T

    2009-01-01

    We have constructed an optical clock with a fractional frequency inaccuracy of 8.6e-18, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser-cool the Al+ ion and detect its quantum state. The frequency of the 1S0->3P0 clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0e-18. The two clocks exhibit a relative stability of 2.8e-15/ sqrt(tau), and a fractional frequency difference of -1.8e-17, consistent with the accuracy limit of the older clock.

  5. Frequency Comparison of Two High-Accuracy Al+ Optical Clocks

    Science.gov (United States)

    Chou, C. W.; Hume, D. B.; Koelemeij, J. C. J.; Wineland, D. J.; Rosenband, T.

    2010-02-01

    We have constructed an optical clock with a fractional frequency inaccuracy of 8.6×10-18, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the S01↔P03 clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0×10-18. The two clocks exhibit a relative stability of 2.8×10-15τ-1/2, and a fractional frequency difference of -1.8×10-17, consistent with the accuracy limit of the older clock.

  6. Study of high-altitude radar altimeter model accuracy and SITAN performance using HAAFT data

    Energy Technology Data Exchange (ETDEWEB)

    Shieves, T.C.; Callahan, M.W.

    1979-07-01

    Radar altimetry data, inertial navigation data, and scoring data were collected under the HAAFT program by Martin Marietta Corporation for the United States Air Force over several areas in the western United States at altitudes ranging from 3 to 20 km. The study reported here uses the HAAFT data in conjunction with Defense Mapping Agency (DMA) topographic data to evaluate the accuracy of a high-altitude pulsed-radar altimeter model and the resulting performance of the terrain-aided guidance concept SITAN. Previous SITAN flight tests at low altitudes (less than 1500 m AGL) have demonstrated 6-20 m CEP. The high-altitude flight test data analyzed herein show a SITAN CEP of 120 m. The radar altimeter model was required to achieve this performance includes the effects of the internal track loop, AGC loop, antenna beamwidth, and the terrain radar cross section and provided a factor of 6 improvement over simple nadir ground clearance for rough terrain. It is postulated that high-altitude CEP could be reduced to 50 m or less if an altimeter were designed specifically for high-altitude terrain sensing.

  7. Sensitivity analysis for high accuracy proximity effect correction

    Science.gov (United States)

    Thrun, Xaver; Browning, Clyde; Choi, Kang-Hoon; Figueiro, Thiago; Hohle, Christoph; Saib, Mohamed; Schiavone, Patrick; Bartha, Johann W.

    2015-10-01

    A sensitivity analysis (SA) algorithm was developed and tested to comprehend the influences of different test pattern sets on the calibration of a point spread function (PSF) model with complementary approaches. Variance-based SA is the method of choice. It allows attributing the variance of the output of a model to the sum of variance of each input of the model and their correlated factors.1 The objective of this development is increasing the accuracy of the resolved PSF model in the complementary technique through the optimization of test pattern sets. Inscale® from Aselta Nanographics is used to prepare the various pattern sets and to check the consequences of development. Fraunhofer IPMS-CNT exposed the prepared data and observed those to visualize the link of sensitivities between the PSF parameters and the test pattern. First, the SA can assess the influence of test pattern sets for the determination of PSF parameters, such as which PSF parameter is affected on the employments of certain pattern. Secondly, throughout the evaluation, the SA enhances the precision of PSF through the optimization of test patterns. Finally, the developed algorithm is able to appraise what ranges of proximity effect correction is crucial on which portion of a real application pattern in the electron beam exposure.

  8. Distributed High Accuracy Peer-to-Peer Localization in Mobile Multipath Environments

    CERN Document Server

    Ekambaram, Venkatesan

    2010-01-01

    In this paper we consider the problem of high accuracy localization of mobile nodes in a multipath-rich environment where sub-meter accuracies are required. We employ a peer to peer framework where the vehicles/nodes can get pairwise multipath-degraded ranging estimates in local neighborhoods together with a fixed number of anchor nodes. The challenge is to overcome the multipath-barrier with redundancy in order to provide the desired accuracies especially under severe multipath conditions when the fraction of received signals corrupted by multipath is dominating. We invoke a message passing analytical framework based on particle filtering and reveal its high accuracy localization promise through simulations.

  9. High Mallampati score, obesity and obstructive sleep apnea: triple insult to lung function?

    Directory of Open Access Journals (Sweden)

    Nazia Uzma

    2014-07-01

    Full Text Available The paper assesses the combined effect of high Mallampati score, obesity and obstructive sleep apnea (OSA on lung function as measured by spirometry. Our results showed that the combination of sleep apnea, obesity and high Mallampati score resulted in a degree of restriction that was significantly greater than that produced by each factor alone. These observations underscore the importance of factoring in the Mallampati score in the assessment of respiratory disease.

  10. Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

    Science.gov (United States)

    Schlegel, T. T.; Arenare, B.; Greco, E. C.; DePalma, J. L.; Starc, V.; Nunez, T.; Medina, R.; Jugo, D.; Rahman, M.A.; Delgado, R.

    2007-01-01

    We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead

  11. Impact of Science Tutoring on African Americans' Science Scores on the High School Students' Graduation Examination

    Science.gov (United States)

    Davis, Edward

    This study investigated the relationship between an after-school tutorial program for African American high school students at a Title I school and scores on the science portion of the High School Graduation Examination (HSGE). Passing the examination was required for graduation. The target high school is 99% African American and the passing rate of the target high school was 42%---lower than the state average of 76%. The purpose of the study was to identify (a) the relationship between a science tutorial program and scores on the science portion of the HSGE, (b) the predictors of tutoring need by analyzing the relationship between biology grades and scores on the science portion of the HSGE, and (c) the findings between biology grades and scores on the science portion of the HSGE by analyzing the relationship between tutorial attendance and HSGE scores. The study was based on Piaget's cognitive constructivism, which implied the potential benefits of tutorials on high-stakes testing. This study used a 1-group pretest-posttest, quantitative methodology. Results showed a significant relationship between tutoring and scores on the biology portion of the HSGE. Results found no significant relationship between the tutorial attendance and the scores on the biology portion of the HSGE or between the biology grades and scores on the biology portion of the HSGE before tutoring. It has implications for positive social change by providing educational stakeholders with empirically-based guidance in determining the potential benefit of tutorial intervention strategies on high school graduation examination scores.

  12. Adaptação para a língua portuguesa e validação do Lunney Scoring Method for Rating Accuracy of Nursing Diagnoses Adaptación a la lengua portuguesa y validación del Lunney Scoring Method for Rating Accuracy of Nursing Diagnoses Adaptation to the Portuguese language and validation of the Lunney Scoring Method for Rating Accuracy of Nursing Diagnoses

    Directory of Open Access Journals (Sweden)

    Diná de Almeida Lopes Monteiro da Cruz

    2007-03-01

    Full Text Available O Lunney Scoring Method for Rating Accuracy of Nursing Diagnoses (LSM é uma escala de diferencial semântico que foi desenvolvida por Lunney para estimar a acurácia dos diagnósticos de enfermagem. O objetivo deste estudo foi adaptar o LSM para a língua portuguesa e avaliar as sua propriedades psicométricas. A escala original foi traduzida para o português, revertida para o inglês e as duas versões em inglês foram comparadas para ajustar a versão em português que passou a ser denominada Escala de Acurácia de Diagnóstico de Enfermagem de Lunney - EADE. Quatro enfermeiras foram orientadas sobre a EADE e a aplicaram em 159 diagnósticos formulados para 26 pacientes de três estudos primários com base nos registros de entrevista e exame físico de cada paciente. Os índices Kappa de Cohen mostraram ausência de concordância entre as avaliadoras, o que indica que o instrumento adaptado não tem confiabilidade satisfatória. Em virtude desse resultado, não foi realizada estimativa de validade.O Lunney Scoring Method for Rating Accuracy of Nursing Diagnoses (LSM es una escala de diferencial semántico desarrollada por Lunney para estimar la perfección de los diagnósticos de enfermería. El objetivo de este estudio fue adaptar el LSM a la lengua portuguesa y evaluar sus propiedades psicométricas. La escala original fue traducida al portugués, revertida al inglés y las dos versiones en inglés fueron comparadas para ajustar la versión en portugués que pasó a ser denominada Escala de Perfeccionamiento de Diagnóstico de Enfermería de Lunney - EPDE. Cuatro enfermeras fueron orientadas sobre la EPDE y la aplicaron a 159 diagnósticos formulados para 26 pacientes de 3 estudios primarios con base en los registros de entrevista y examen físico de cada paciente. Los índices Kappa de Cohen mostraron ausencia de concordancia entre las evaluadoras, lo que indica que el instrumento adaptado no tiene confiabilidad satisfactoria. En virtud

  13. The high-density lipoprotein-adjusted SCORE model worsens SCORE-based risk classification in a contemporary population of 30 824 Europeans

    DEFF Research Database (Denmark)

    Mortensen, Martin B; Afzal, Shoaib; Nordestgaard, Børge G

    2015-01-01

    AIMS: Recent European guidelines recommend to include high-density lipoprotein (HDL) cholesterol in risk assessment for primary prevention of cardiovascular disease (CVD), using a SCORE-based risk model (SCORE-HDL). We compared the predictive performance of SCORE-HDL with SCORE in an independent......, contemporary, 'low-risk' European population, focusing on ability to identify those in need of intensified CVD prevention. METHODS AND RESULTS: Between 2003 and 2008, 46,092 individuals without CVD, diabetes, or statin use were enrolled in the Copenhagen General Population Study (CGPS). During a mean of 6.......8 years of follow-up, 339 individuals died of CVD. In the SCORE target population (age 40-65; n = 30,824), fewer individuals were at baseline categorized as high risk (≥5% 10-year risk of fatal CVD) using SCORE-HDL compared with SCORE (10 vs. 17% in men, 1 vs. 3% in women). SCORE-HDL did not improve...

  14. High-accuracy Subdaily ERPs from the IGS

    Science.gov (United States)

    Ray, J. R.; Griffiths, J.

    2012-04-01

    Since November 2000 the International GNSS Service (IGS) has published Ultra-rapid (IGU) products for near real-time (RT) and true real-time applications. They include satellite orbits and clocks, as well as Earth rotation parameters (ERPs) for a sliding 48-hr period. The first day of each update is based on the most recent GPS and GLONASS observational data from the IGS hourly tracking network. At the time of release, these observed products have an initial latency of 3 hr. The second day of each update consists of predictions. So the predictions between about 3 and 9 hr into the second half are relevant for true RT uses. Originally updated twice daily, the IGU products since April 2004 have been issued every 6 hr, at 3, 9, 15, and 21 UTC. Up to seven Analysis Centers (ACs) contribute to the IGU combinations. Two sets of ERPs are published with each IGU update, observed values at the middle epoch of the first half and predicted values at the middle epoch of the second half. The latency of the near RT ERPs is 15 hr while the predicted ERPs, based on projections of each AC's most recent determinations, are issued 9 hr ahead of their reference epoch. While IGU ERPs are issued every 6 hr, each set represents an integrated estimate over the surrounding 24 hr. So successive values are temporally correlated with about 75% of the data being common; this fact should be taken into account in user assimilations. To evaluate the accuracy of these near RT and predicted ERPs, they have been compared to the IGS Final ERPs, available about 11 to 17 d after data collection. The IGU products improved dramatically in the earlier years but since about 2008.0 the performance has been stable and excellent. During the last three years, RMS differences for the observed IGU ERPs have been about 0.036 mas and 0.0101 ms for each polar motion component and LOD respectively. (The internal precision of the reference IGS ERPs over the same period is about 0.016 mas for polar motion and 0

  15. A study for high accuracy real-time 3D ultrasonic location system.

    Science.gov (United States)

    Zhou, Ping; Ha, Zhang; Zhou, Kangyuan

    2006-12-22

    We discussed a high accuracy real-time 3D ultrasonic location system in this article. The signal received was sampled after it passed the TGC and the logarithmic amplifier. Inside the DSP, we used the dynamic threshold tracing technique to improve the accuracy. The result was processed with Weighted Arithmetic Average. By testing the 40 kHz 3D location system, we have arrived at the accuracy of 1 cm.

  16. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior st

  17. Development of high accuracy and resolution geoid and gravity maps

    Science.gov (United States)

    Gaposchkin, E. M.

    1986-01-01

    Precision satellite to satellite tracking can be used to obtain high precision and resolution maps of the geoid. A method is demonstrated to use data in a limited region to map the geopotential at the satellite altitude. An inverse method is used to downward continue the potential to the Earth surface. The method is designed for both satellites in the same low orbit.

  18. Rigorous Training of Dogs Leads to High Accuracy in Human Scent Matching-To-Sample Performance.

    Directory of Open Access Journals (Sweden)

    Sophie Marchal

    Full Text Available Human scent identification is based on a matching-to-sample task in which trained dogs are required to compare a scent sample collected from an object found at a crime scene to that of a suspect. Based on dogs' greater olfactory ability to detect and process odours, this method has been used in forensic investigations to identify the odour of a suspect at a crime scene. The excellent reliability and reproducibility of the method largely depend on rigor in dog training. The present study describes the various steps of training that lead to high sensitivity scores, with dogs matching samples with 90% efficiency when the complexity of the scents presented during the task in the sample is similar to that presented in the in lineups, and specificity reaching a ceiling, with no false alarms in human scent matching-to-sample tasks. This high level of accuracy ensures reliable results in judicial human scent identification tests. Also, our data should convince law enforcement authorities to use these results as official forensic evidence when dogs are trained appropriately.

  19. High accuracy magnetic field sensors with wide operation temperature range

    Science.gov (United States)

    Vasil'evskii, I. S.; Vinichenko, A. N.; Rubakin, D. I.; Bolshakova, I. A.; Kargin, N. I.

    2016-10-01

    n+InAs(Si) epitaxial thin films heavily doped by silicon and Hall effect magnetic field sensors based on this structures have been fabricated and studied. We have demonstrated the successful formation of highly doped InAs thin films (∼100 nm) with the different intermediate layer arrangement and appropriate electron mobility values. Hall sensors performance parameters have been measured in wide temperature range. Obtained sensitivity varied from 1 to 40 Ω/T, while the best linearity and lower temperature coefficient have been found in the higher doped samples with lower electron mobility. We attribute this to the electron system degeneracy and decreased phonon contribution to electron mobility and resistance.

  20. A High Accuracy Method for Semi-supervised Information Extraction

    Energy Technology Data Exchange (ETDEWEB)

    Tratz, Stephen C.; Sanfilippo, Antonio P.

    2007-04-22

    Customization to specific domains of dis-course and/or user requirements is one of the greatest challenges for today’s Information Extraction (IE) systems. While demonstrably effective, both rule-based and supervised machine learning approaches to IE customization pose too high a burden on the user. Semi-supervised learning approaches may in principle offer a more resource effective solution but are still insufficiently accurate to grant realistic application. We demonstrate that this limitation can be overcome by integrating fully-supervised learning techniques within a semi-supervised IE approach, without increasing resource requirements.

  1. Head to head comparison of the propensity score and the high-dimensional propensity score matching methods

    Directory of Open Access Journals (Sweden)

    Jason R. Guertin

    2016-02-01

    Full Text Available Abstract Background Comparative performance of the traditional propensity score (PS and high-dimensional propensity score (hdPS methods in the adjustment for confounding by indication remains unclear. We aimed to identify which method provided the best adjustment for confounding by indication within the context of the risk of diabetes among patients exposed to moderate versus high potency statins. Method A cohort of diabetes-free incident statins users was identified from the Quebec’s publicly funded medico-administrative database (Full Cohort. We created two matched sub-cohorts by matching one patient initiated on a lower potency to one patient initiated on a high potency either on patients’ PS or hdPS. Both methods’ performance were compared by means of the absolute standardized differences (ASDD regarding relevant characteristics and by means of the obtained measures of association. Results Eight out of the 18 examined characteristics were shown to be unbalanced within the Full Cohort. Although matching on either method achieved balance within all examined characteristic, matching on patients’ hdPS created the most balanced sub-cohort. Measures of associations and confidence intervals obtained within the two matched sub-cohorts overlapped. Conclusion Although ASDD suggest better matching with hdPS than with PS, measures of association were almost identical when adjusted for either method. Use of the hdPS method in adjusting for confounding by indication within future studies should be recommended due to its ability to identify confounding variables which may be unknown to the investigators.

  2. Traffic Sign Recognition with High Accuracy Using Mixture of Experts

    Directory of Open Access Journals (Sweden)

    Reza Azad

    2014-06-01

    Full Text Available Traffic signs provide the driver various information for safe and efficient navigation. Automatic recognition of traffic signs is, therefore, important for automated driving or driver assistance systems.In this paper, a new and efficient traffic sign recognition system based on extracting diverse feature set, and applying mixture of experts'architecture on the extracted featuresis proposed.In the result part, the proposed approach is evaluated on the German traffic sign recognition and Grigorescu traffic signsbenchmark and high recognition rate is achieved.Comparison with some of the most related methods indicates that the proposed novel model yields excellent recognition rate in traffic sign recognition that is the recognition rate of 99.94% for the training set and 98.50% for the test set.In addition, experimental results have demonstrated our method robust in successful recognition of traffic signs even with variant lighting.

  3. Gated viewing and high-accuracy three-dimensional laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a fast and high-accuracy three-dimensional (3-D) imaging laser radar that can achieve better than 1 mm range accuracy for half a million pixels in less than 1 s. Our technique is based on range-gating segmentation. We combine the advantages of gated viewing with our new fast...

  4. Gated viewing and high-accuracy three-dimensional laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a fast and high-accuracy three-dimensional (3-D) imaging laser radar that can achieve better than 1 mm range accuracy for half a million pixels in less than 1 s. Our technique is based on range-gating segmentation. We combine the advantages of gated viewing with our new fast...

  5. A High-Throughput, High-Accuracy System-Level Simulation Framework for System on Chips

    Directory of Open Access Journals (Sweden)

    Guanyi Sun

    2011-01-01

    Full Text Available Today's System-on-Chips (SoCs design is extremely challenging because it involves complicated design tradeoffs and heterogeneous design expertise. To explore the large solution space, system architects have to rely on system-level simulators to identify an optimized SoC architecture. In this paper, we propose a system-level simulation framework, System Performance Simulation Implementation Mechanism, or SPSIM. Based on SystemC TLM2.0, the framework consists of an executable SoC model, a simulation tool chain, and a modeling methodology. Compared with the large body of existing research in this area, this work is aimed at delivering a high simulation throughput and, at the same time, guaranteeing a high accuracy on real industrial applications. Integrating the leading TLM techniques, our simulator can attain a simulation speed that is not slower than that of the hardware execution by a factor of 35 on a set of real-world applications. SPSIM incorporates effective timing models, which can achieve a high accuracy after hardware-based calibration. Experimental results on a set of mobile applications proved that the difference between the simulated and measured results of timing performance is within 10%, which in the past can only be attained by cycle-accurate models.

  6. The accuracy of QCD perturbation theory at high energies

    CERN Document Server

    Dalla Brida, Mattia; Korzec, Tomasz; Ramos, Alberto; Sint, Stefan; Sommer, Rainer

    2016-01-01

    We discuss the determination of the strong coupling $\\alpha_\\mathrm{\\overline{MS}}^{}(m_\\mathrm{Z})$ or equivalently the QCD $\\Lambda$-parameter. Its determination requires the use of perturbation theory in $\\alpha_s(\\mu)$ in some scheme, $s$, and at some energy scale $\\mu$. The higher the scale $\\mu$ the more accurate perturbation theory becomes, owing to asymptotic freedom. As one step in our computation of the $\\Lambda$-parameter in three-flavor QCD, we perform lattice computations in a scheme which allows us to non-perturbatively reach very high energies, corresponding to $\\alpha_s = 0.1$ and below. We find that perturbation theory is very accurate there, yielding a three percent error in the $\\Lambda$-parameter, while data around $\\alpha_s \\approx 0.2$ is clearly insufficient to quote such a precision. It is important to realize that these findings are expected to be generic, as our scheme has advantageous properties regarding the applicability of perturbation theory.

  7. Methodology of High Accuracy and Resolution 3D Geological Model Generation and Application

    Institute of Scientific and Technical Information of China (English)

    吴键; 曹代勇; 邓爱居; 李东津; 蒋涛; 翟光华

    2004-01-01

    By generating a high accuracy and high resolution geological model in Liuchu oil field, the technique of geological modeling is expanded and involved in primary geological study, making the sand bodies and reservoir be easily described in detail. The 3D visualization and 3D interactive editing of geological structure model are the key for modeling procedure. And a high accuracy and resolution geological model has been well applied in optimizing the production scheme.

  8. Differentiation of prostate cancer lesions with high and with low Gleason score by diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barbieri, Sebastiano; Broennimann, Michael; Vermathen, Peter; Thoeny, Harriet C. [Inselspital University Hospital, Institute of Diagnostic, Pediatric, and Interventional Radiology, Bern (Switzerland); Boxler, Silvan [Inselspital, Inselspital University Hospital, Department of Urology, Bern (Switzerland)

    2017-04-15

    To differentiate prostate cancer lesions with high and with low Gleason score by diffusion-weighted-MRI (DW-MRI). This prospective study was approved by the responsible ethics committee. DW-MRI of 84 consenting prostate and/or bladder cancer patients scheduled for radical prostatectomy were acquired and used to compute apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM: the pure diffusion coefficient D{sub t}, the pseudo-diffusion fraction F{sub p} and the pseudo-diffusion coefficient D{sub p}), and high b value (as acquired and Hessian filtered) parameters within the index lesion. These parameters (separately and combined in a logistic regression model) were used to differentiate lesions depending on whether whole-prostate histopathological analysis after prostatectomy determined a high (≥7) or low (6) Gleason score. Mean ADC and D{sub t} differed significantly (p of independent two-sample t test < 0.01) between high- and low-grade lesions. The highest classification accuracy was achieved by the mean ADC (AUC 0.74) and D{sub t} (AUC 0.70). A logistic regression model based on mean ADC, mean F{sub p} and mean high b value image led to an AUC of 0.74 following leave-one-out cross-validation. Classification by IVIM parameters was not superior to classification by ADC. DW-MRI parameters correlated with Gleason score but did not provide sufficient information to classify individual patients. (orig.)

  9. The ability of the 2013 American College of Cardiology/American Heart Association cardiovascular risk score to identify rheumatoid arthritis patients with high coronary artery calcification scores.

    Science.gov (United States)

    Kawai, Vivian K; Chung, Cecilia P; Solus, Joseph F; Oeser, Annette; Raggi, Paolo; Stein, C Michael

    2015-02-01

    Patients with rheumatoid arthritis (RA) have increased risk of atherosclerotic cardiovascular disease that is underestimated by the Framingham Risk Score (FRS). We undertook this study to test the hypothesis that the 2013 American College of Cardiology/American Heart Association (ACC/AHA) 10-year risk score would perform better than the FRS and the Reynolds Risk Score (RRS) in identifying RA patients known to have elevated cardiovascular risk based on high coronary artery calcification (CAC) scores. Among 98 RA patients eligible for risk stratification using the ACC/AHA risk score, we identified 34 patients with high CAC (defined as ≥300 Agatston units or ≥75th percentile of expected coronary artery calcium for age, sex, and ethnicity) and compared the ability of the 10-year FRS, RRS, and ACC/AHA risk scores to correctly assign these patients to an elevated risk category. All 3 risk scores were higher in patients with high CAC (P risk category was similar among the 3 scores (FRS 32%, RRS 32%, ACC/AHA risk score 41%) (P = 0.223). The C statistics for the FRS, RRS, and ACC/AHA risk score predicting the presence of high CAC were 0.65, 0.66, and 0.65, respectively. The ACC/AHA 10-year risk score does not offer any advantage compared to the traditional FRS and RRS in the identification of RA patients with elevated risk as determined by high CAC. The ACC/AHA risk score assigned almost 60% of patients with high CAC to a low risk category. Risk scores and standard risk prediction models used in the general population do not adequately identify many RA patients with elevated cardiovascular risk.

  10. High-speed, high-accuracy large range 3D measurement

    Science.gov (United States)

    An, Yatong; Zhang, Song

    2017-05-01

    This paper presents such a high-speed, high-accuracy structured light technique that could achieve large range 3D shape measurement. The enabling method is our recently proposed system calibration that splits the calibration process into two stages. Specifically, we calibrate the intrinsic parameters at a near position with a regular size yet precisely fabricated calibration target, and then calibrate the extrinsic parameters with the assistance of an additional large range yet low accuracy low cost 3D scanner (i.e., Kinect). We developed a system that achieved 500 Hz with a resolution 2304 × 1400. The field of view (FOV) of our structured light system is 0.9 m(W) × 1.4 m(H) × 0.8 m(D). Our experimental data demonstrated that such a large range structured light system can achieve an mean error of 0.13 mm with a standard deviation of 1.18 mm by measuring a 304.8 mm diameter sphere. We further experimentally demonstrated that proposed method can simultaneously measure multiple objects or large dynamically changing objects.

  11. Beyond Correlations: Usefulness of High School GPA and Test Scores in Making College Admissions Decisions

    Science.gov (United States)

    Sawyer, Richard

    2013-01-01

    Correlational evidence suggests that high school GPA is better than admission test scores in predicting first-year college GPA, although test scores have incremental predictive validity. The usefulness of a selection variable in making admission decisions depends in part on its predictive validity, but also on institutions' selectivity and…

  12. ACT Scores of Incoming Freshmen to New Mexico State University by High School Size.

    Science.gov (United States)

    Edington, Everett D.

    The American College Testing (ACT) scores of New Mexico public high school graduates who applied for admission to New Mexico State University in 1981 were analyzed to determine the relationship between ACT scores and school size. The schools were divided into 6 categories according to enrollment: less than 100 students (15 applicants), 100-199…

  13. State of the art in high accuracy high detail DTMs derived from ALS

    Science.gov (United States)

    Pfeifer, N.; Briese, C.; Mandlburger, G.; Höfle, B.; Ressl, C.

    2009-04-01

    High-resolution Digital Terrain Models (DTMs) representing the bare Earth are a fundamental input for various applications in geomorphology. Airborne laser scanning (ALS) is established as a standard tool for deriving DTMs over large areas with unprecedented accuracy. Due to advances in sensor technology and in processing algorithms in the recent years the obtainable accuracy is still increasing. Accuracy is understood as the deviation from the elevation at one specified point to its true value. These advances may lead to a more efficient data acquisition, if reduced accuracy is targeted, but also allow data acquisition schemes with more detail becoming visible, i.e. small features of the relief. For the latter a high internal precision, i.e. repeatability, is necessary. The essential advances in the technologies are improvements in ranging through the introduction of full-waveform (FWF) laser scanning and rigorous models of strip adjustment. In FWF laser scanning the time-dependent strength of the backscattered signal is recorded. This is opposed to the analogue processing of the incoming energy and storage of one arrival time of discrete-return systems. In a simple one-echo situation, the arrival time corresponds to the maximum of the waveform. By applying a decomposition of the full waveform into single echoes, which are transformed copies of the emitted signal, it is possible to retrieve more echoes per shot. Additionally, if echoes of individual scatterers are overlapping, FWF sensors might be able to separate them, whereas discrete return systems might rather only be able to derive one collective arrival time. Finally, the overlay of two echoes does not have the maxima at the same positions as the individual echoes. Additionally, the pulse repetition rate of laser scanners has increased, which allows higher point densities and therefore higher richness of detail. These advances in data acquisition increase the precision within one ALS strip. Deficiencies in

  14. High-accuracy determination for optical indicatrix rotation in ferroelectric DTGS

    OpenAIRE

    O.S.Kushnir; O.A.Bevz; O.G.Vlokh

    2000-01-01

    Optical indicatrix rotation in deuterated ferroelectric triglycine sulphate is studied with the high-accuracy null-polarimetric technique. The behaviour of the effect in ferroelectric phase is referred to quadratic spontaneous electrooptics.

  15. High-accuracy interferometric measurements of flatness and parallelism of a step gauge

    CSIR Research Space (South Africa)

    Kruger, OA

    2001-01-01

    Full Text Available for the calibration of step gauges to a high accuracy. A system was also developed for interferometric measurements of the flatness and parallelism of gauge block faces for use in uncertainty calculations....

  16. High Accuracy Reference Network (HARN), Points generated from coordinates supplied by NGS, Published in 1993, MARIS.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This High Accuracy Reference Network (HARN) dataset, was produced all or in part from Field Survey/GPS information as of 1993. It is described as 'Points generated...

  17. Data supporting the high-accuracy haplotype imputation using unphased genotype data as the references

    Directory of Open Access Journals (Sweden)

    Wenzhi Li

    2016-09-01

    Full Text Available The data presented in this article is related to the research article entitled “High-accuracy haplotype imputation using unphased genotype data as the references” which reports the unphased genotype data can be used as reference for haplotyping imputation [1]. This article reports different implementation generation pipeline, the results of performance comparison between different implementations (A, B, and C and between HiFi and three major imputation software tools. Our data showed that the performances of these three implementations are similar on accuracy, in which the accuracy of implementation-B is slightly but consistently higher than A and C. HiFi performed better on haplotype imputation accuracy and three other software performed slightly better on genotype imputation accuracy. These data may provide a strategy for choosing optimal phasing pipeline and software for different studies.

  18. Accuracy of the field triage protocol in selecting severely injured patients after high energy trauma.

    Science.gov (United States)

    van Laarhoven, J J E M; Lansink, K W W; van Heijl, M; Lichtveld, R A; Leenen, L P H

    2014-05-01

    For optimal treatment of trauma patients it is of great importance to identify patients who are at risk for severe injuries. The Dutch field triage protocol for trauma patients, the LPA (National Protocol of Ambulance Services), is designed to get the right patient, in the right time, to the right hospital. Purpose of this study was to determine diagnostic accuracy and compliance of this triage protocol. Triage criteria were categorised into physiological condition (P), mechanism of trauma (M) and injury type (I). A retrospective analysis of prospectively collected data of all high-energy trauma patients from 2008 to 2011 in the region Central Netherlands is performed. Diagnostic parameters (sensitivity, specificity, negative predictive value, positive predictive value) of the field triage protocol for selecting severely injured patients were calculated including rates of under- and overtriage. Undertriage was defined as the proportion of severely injured patients (Injury Severity Score (ISS)≥16) who were transported to a level two or three trauma care centre. Overtriage was defined as the proportion of non-severely injured patients (ISSprotocol was 89.1% (95% confidence interval (CI) 84.4-92.6) and 60.5% (95% CI 57.9-63.1), respectively. The overall rate of undertriage was 10.9% (95%CI 7.4-15.7) and the overall rate of overtriage was 39.5% (95%CI 36.9-42.1). These rates were 16.5% and 37.7%, respectively for patients with M+I-P-. Compliance to the triage protocol for patients with M+I-P- was 78.7%. Furthermore, compliance in patients with either a positive I+ or positive P+ was 91.2%. The overall rate of undertriage (10.8%) was mainly influenced by a high rate of undertriage in the group of patients with only a positive mechanism criterion, therefore showing low diagnostic accuracy in selecting severely injured patients. As a consequence these patients with severe injury are undetected using the current triage protocol. As it has been shown that severely injured

  19. High-Order Kinetic Relaxation Schemes as High-Accuracy Poisson Solvers

    CERN Document Server

    Mendoza, M; Herrmann, H J

    2015-01-01

    We present a new approach to find accurate solutions to the Poisson equation, as obtained from the steady-state limit of a diffusion equation with strong source terms. For this purpose, we start from Boltzmann's kinetic theory and investigate the influence of higher order terms on the resulting macroscopic equations. By performing an appropriate expansion of the equilibrium distribution, we provide a method to remove the unnecessary terms up to a desired order and show that it is possible to find, with high level of accuracy, the steady-state solution of the diffusion equation for sizeable Knudsen numbers. In order to test our kinetic approach, we discretise the Boltzmann equation and solve the Poisson equation, spending up to six order of magnitude less computational time for a given precision than standard lattice Boltzmann methods.

  20. Do mothers with high sodium levels in their breast milk have high depression and anxiety scores?

    Science.gov (United States)

    Serim Demirgoren, Burcu; Ozbek, Aylin; Ormen, Murat; Kavurma, Canem; Ozer, Esra; Aydın, Adem

    2017-04-01

    Objective This study aimed to assess the possible association of high breast milk sodium levels with postpartum depression and anxiety. Methods A total of 150 mothers and their healthy, exclusively breastfed newborns aged 8 to 15 days were recruited. Mothers were asked to complete scales for evaluation of postnatal depression and anxiety following an interview for consent and sociodemographic data collection. Breast milk samples were obtained to measure sodium and potassium (K) levels. Results Forty-nine mothers had higher than expected breast milk Na concentrations and a high Na/K ratio. These mothers scored significantly higher on the scales of postnatal depression and state anxiety ( P = 0.018 and P = 0.048, respectively). Conclusions This study shows that compared to normal breast milk Na levels and Na/K ratio, high breast milk Na and high Na/K ratio, with possible serious consequences in infants, are associated with maternal depressive and anxious symptoms in the postpartum period.

  1. The Kilimanjaro score for assessing fitness to fly paragliders at high altitude.

    Science.gov (United States)

    Wilkes, Matt; Simpson, Alistair; Knox, Matt; Summers, Luke

    2013-09-01

    Extreme sports such as paragliding are increasing in popularity, providing continued challenges for the development of safe practice techniques. In January and February 2013, the Wings of Kilimanjaro expedition aimed to launch 95 paragliders from the summit of Mount Kilimanjaro, 5790 m above sea level. A safe launch was paramount but risked being impaired by adverse environmental conditions, in particular the pathophysiological effects of high altitude. There are no existing scores to assess fitness for high-altitude paraglider launches present in the literature. A novel scoring system, the Kilimanjaro Score, was therefore developed to rapidly assess pilots pre-flight. The Kilimanjaro Score aimed to assess cognition, memory, and visual-spatial skill within the context of standard pre-flight checks. Further testing, including the Lake Louise Score, was to be performed if the pilot's Kilimanjaro Score was deemed unsatisfactory. We present the Kilimanjaro Score here for comment and refinement, and we invite other parties to consider its use in the field for high altitude paragliding activities.

  2. Highly charged ions as a basis of optical atomic clockwork of exceptional accuracy.

    Science.gov (United States)

    Derevianko, Andrei; Dzuba, V A; Flambaum, V V

    2012-11-02

    We propose a novel class of atomic clocks based on highly charged ions. We consider highly forbidden laser-accessible transitions within the 4f(12) ground-state configurations of highly charged ions. Our evaluation of systematic effects demonstrates that these transitions may be used for building exceptionally accurate atomic clocks which may compete in accuracy with recently proposed nuclear clocks.

  3. High resolution CT in children with cystic fibrosis: correlation with pulmonary functions and radiographic scores

    Energy Technology Data Exchange (ETDEWEB)

    Demirkazik, Figen Basaran E-mail: demirkaz@dialup.ankara.edu.tr; Ariyuerek, O. Macit; Oezcelik, Ugur; Goecmen, Ayhan; Hassanabad, Hossein K.; Kiper, Nural

    2001-01-01

    Objective: To compare the high resolution CT (HRCT) scores of the Bhalla system with pulmonary function tests and radiographic and clinical points of the Shwachman-Kulczycki clinical scoring system. Methods: HRCT of the chest was obtained in 40 children to assess the role of HRCT in evaluating bronchopulmonary pathology in children with cystic fibrosis (CF). The HRCT severity scores of the Bhalla system were compared with chest radiographic and clinical points of the Shwachman-Kulczycki scoring system and pulmonary function tests. Only 14 of the patients older than 6 years cooperated with spirometry. Results: HRCT scores correlated well with radiographic points (r=0.80, P<0.0001) and clinical points (r=0.67, P<0.0001) of the Shwachman-Kulczycki system, FVC (r=0.71 P=0.004) and FEV{sub 1} (r=0.66, P=0.01). Although radiographic points correlated significantly with FVC (r=0.61, P=0.02) and FEV{sub 1} (r=0.56, P=0.04), HRCT provides a more precise scoring than the chest X-ray. Conclusion: The HRCT scoring system may provide a sensitive method of monitoring pulmonary disease status and may replace the radiographic scoring in the Shwachman-Kulczycki system. It may be helpful especially in follow-up of small children too young to cooperate with spirometry.

  4. Grades--Scores--Predictions: A Study of the Efficiency of High School Grades and American College Test Scores in Predicting Academic Achievement at Montgomery College.

    Science.gov (United States)

    Gell, Robert L.; Bleil, David F.

    This report analyzes the relationship between high school grades, American College Test (ACT) scores, and first-semester college grades. Based on the Standard Research Service of the ACT program, 1,379 students in the fall 1969 freshman class of Montgomery College (Maryland) were studied. Measures of academic background used ACT scores in English,…

  5. The effect of pattern overlap on the accuracy of high resolution electron backscatter diffraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Vivian, E-mail: v.tong13@imperial.ac.uk [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Jiang, Jun [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Wilkinson, Angus J. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Britton, T. Ben [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom)

    2015-08-15

    High resolution, cross-correlation-based, electron backscatter diffraction (EBSD) measures the variation of elastic strains and lattice rotations from a reference state. Regions near grain boundaries are often of interest but overlap of patterns from the two grains could reduce accuracy of the cross-correlation analysis. To explore this concern, patterns from the interior of two grains have been mixed to simulate the interaction volume crossing a grain boundary so that the effect on the accuracy of the cross correlation results can be tested. It was found that the accuracy of HR-EBSD strain measurements performed in a FEG-SEM on zirconium remains good until the incident beam is less than 18 nm from a grain boundary. A simulated microstructure was used to measure how often pattern overlap occurs at any given EBSD step size, and a simple relation was found linking the probability of overlap with step size. - Highlights: • Pattern overlap occurs at grain boundaries and reduces HR-EBSD accuracy. • A test is devised to measure the accuracy of HR-EBSD in the presence of overlap. • High pass filters can sometimes, but not generally, improve HR-EBSD measurements. • Accuracy of HR-EBSD remains high until the reference pattern intensity is <72%. • 9% of points near a grain boundary will have significant error for 200nm step size in Zircaloy-4.

  6. The AIMS65 Score Is a Useful Predictor of Mortality in Patients with Nonvariceal Upper Gastrointestinal Bleeding: Urgent Endoscopy in Patients with High AIMS65 Scores.

    Science.gov (United States)

    Park, Sun Wook; Song, Young Wook; Tak, Dae Hyun; Ahn, Byung Moo; Kang, Sun Hyung; Moon, Hee Seok; Sung, Jae Kyu; Jeong, Hyun Yong

    2015-11-01

    To validate the AIMS65 score for predicting mortality of patients with nonvariceal upper gastrointestinal bleeding and to evaluate the effectiveness of urgent (Nonvariceal, upper gastrointestinal bleeding was assessed by using the AIM65 and Rockall scores. Scores for mortality were assessed by calculating the area under the receiver-operating characteristic curve (AUROC). Patients with high AIMS65 scores (≥2) were allocated to either the urgent or non-urgent endoscopic procedure group. In-hospital mortality, success of endoscopic procedure, recurrence of bleeding, admission period, and dose of transfusion were compared between groups. A total of 634 patients were analyzed. The AIMS65 score successfully predicted mortality (AUROC=0.943; 95% confidence interval [CI], 0.876 to 0.99) and was superior to the Rockall score (AUROC=0.856; 95% CI, 0.743 to 0.969) in predicting mortality. The group with high AIMS65 score included 200 patients. The urgent endoscopic procedure group had reduced hospitalization periods (pnonvariceal upper gastrointestinal bleeding. Urgent endoscopic procedures in patients with high scores may be related to reduced hospitalization periods.

  7. Development of an automatic calibration device for high-accuracy low temperature thermometers

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Based on the analysis and investigation of calibration systems for high-accuracy low temperature thermometers,a new facility for automatic calibration of high-accuracy low temperature thermometers was developed.Continuous calibration for multiple points can be made automatically with this device.According to the thermophysical characteristics of the constant-temperature block in this device,segmented Fuzzy-PID (proportional-integral-differential) algorithm was applied.The experimental results showed that the temperature fluctuation was smaller than ±0.005 K in 30 min.Therefore,this new device can fully meet the calibration requirement of high-precision low temperature thermometers.

  8. Stories Behind High IELTS Scores(Ⅰ)——Liu Yuhan's Moderate Mentality

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    @@ Before having any contact with LIU Yuhan,we were totally surprised by her IELTS score-8.5in Listening,8.5 in Reading.7.5 in Speaking,and 7 in Writing.This excellent score,a total of 8,was achieved by a Grade Two senior middle school student.Interests in hearing her story and her learning methods were highly boosted.

  9. Study on High Accuracy Topographic Mapping via UAV-based Images

    Science.gov (United States)

    Chi, Yun-Yao; Lee, Ya-Fen; Tsai, Shang-En

    2016-10-01

    Unmanned aerial vehicle (UAV) provides a promising tool for the acquisition of such multi-temporal aerial stereo photos and high-resolution digital surface models. Recently, the flight of UAVs operates with high degrees of autonomy by the global position system and onboard digit camera and computer. The UAV-based mapping can be obtained faster and cheaper, but its accuracy is anxious. This paper aims to identify the integration ability of high accuracy topographic map via the image of quad-rotors UAV and ground control points (GCPs). The living survey data is collected in the Errn river basins area in Tainan, Taiwan. The high accuracy UAV-based topographic in the study area is calibrated by the local coordinate of GCPs using the total station with the accuracy less than 1/2000. The comparison results show the accuracy of UAV-based topographic is accepted by overlapping. The results can be a reference for the practice works of mapping survey in earth.

  10. Links Among High EPDS Scores, State of Mind Regarding Attachment, and Symptoms of Personality Disorder.

    Science.gov (United States)

    Smith-Nielsen, Johanne; Steele, Howard; Mehlhase, Heike; Cordes, Katharina; Steele, Miriam; Harder, Susanne; Væver, Mette Skovgaard

    2015-12-01

    Underlying persistent psychological difficulties have been found to moderate potential adverse effects of maternal postpartum depression (PPD) on parenting and infant development. The authors examined whether mothers presenting postpartum depressive symptoms showed higher levels of personality pathology and more insecure state of mind regarding attachment compared to nondepressed mothers. Participants (N = 85) were assessed with the Edinburgh Postnatal Depression Scale (EPDS), the Present State Examination, the Adult Attachment Interview, and the Structured Clinical Interview for DSM-IV Axis II. Mothers with high EPDS scores were more likely to have a preoccupied insecure state of mind and to have personality disorder compared with mothers scoring below clinical cutoff. Furthermore, multiple regression analysis showed that personality disorder and AAI classification were independently related to EPDS score, and that these two factors together accounted for 48% of the variance in EPDS score. Findings are discussed in terms of heterogeneity in PPD populations and underline the importance of examining potential coexisting psychological difficulties when studying PPD.

  11. Very high-accuracy calibration of radiation pattern and gain of a near-field probe

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Nielsen, Jeppe Majlund; Breinbjerg, Olav

    2014-01-01

    In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission of the Europ......In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission...

  12. Spontaneous mentalizing in neurotypicals scoring high versus low on symptomatology of autism spectrum disorder.

    Science.gov (United States)

    Nijhof, Annabel D; Brass, Marcel; Wiersema, Jan R

    2017-09-25

    Spontaneous mentalizing ability has been linked to symptoms severity in individuals with autism spectrum disorder (ASD). Here we investigated whether in neurotypicals, higher levels of ASD symptomatology could also be linked to lower levels of spontaneous mentalizing, by comparing neurotypicals scoring high with those scoring low on the short Autism Spectrum Quotient. Participants watched movies during which they, and another agent, formed beliefs about the location of an object. These beliefs could influence reaction times (RT) to that object in the outcome phase. We expected participants with more ASD symptoms to show less spontaneous mentalizing, as reflected by a smaller effect of the other agent's beliefs on RT patterns (the ToM index). In contrast, the effect of own beliefs on RTs, reflecting an egocentric bias, was expected to be larger in the high-scoring group. Results showed that groups differed in the effect of the agent's beliefs; the ToM index was highly significant in the low-scoring group, while being absent in the high-scoring group. No difference in egocentric bias was observed. These findings suggest that the relationship between levels of ASD symptomatology and spontaneous mentalizing is not only present in individuals with ASD, but also in the neurotypical population. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. [Study on high accuracy detection of multi-component gas in oil-immerse power transformer].

    Science.gov (United States)

    Fan, Jie; Chen, Xiao; Huang, Qi-Feng; Zhou, Yu; Chen, Gang

    2013-12-01

    In order to solve the problem of low accuracy and mutual interference in multi-component gas detection, a kind of multi-component gas detection network with high accuracy was designed. A semiconductor laser with narrow bandwidth was utilized as light source and a novel long-path gas cell was also used in this system. By taking the single sine signal to modulate the spectrum of laser and using space division multiplexing (SDM) and time division multiplexing (TDM) technique, the detection of multi-component gas was achieved. The experiments indicate that the linearity relevance coefficient is 0. 99 and the measurement relative error is less than 4%. The system dynamic response time is less than 15 s, by filling a volume of multi-component gas into the gas cell gradually. The system has advantages of high accuracy and quick response, which can be used in the fault gas on-line monitoring for power transformers in real time.

  14. Use of the SONET Score to Evaluate High Volume Emergency Department Overcrowding: A Prospective Derivation and Validation Study

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2015-01-01

    Full Text Available Background. The accuracy and utility of current Emergency Department (ED crowding estimation tools remain uncertain in EDs with high annual volumes. We aimed at deriving a more accurate tool to evaluate overcrowding in a high volume ED setting and determine the association between ED overcrowding and patient care outcomes. Methods. A novel scoring tool (SONET: Severely overcrowded-Overcrowded-Not overcrowded Estimation Tool was developed and validated in two EDs with both annual volumes exceeding 100,000. Patient care outcomes including the number of left without being seen (LWBS patients, average length of ED stay, ED 72-hour returns, and mortality were compared under the different crowding statuses. Results. The total number of ED patients, the number of mechanically ventilated patients, and patient acuity levels were independent risk factors affecting ED overcrowding. SONET was derived and found to better differentiate severely overcrowded, overcrowded, and not overcrowded statuses with similar results validated externally. In addition, SONET scores correlated with increased length of ED stay, number of LWBS patients, and ED 72-hour returns. Conclusions. SONET might be a better fit to determine high volume ED overcrowding. ED overcrowding negatively impacts patient care operations and often produces poor patient perceptions of standardized care delivery.

  15. Analysis of Accuracy of a High-speed Mobile Platform Control System

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The efficient manufacture technique involves a high-speed control of platform mobile system. A linear acutor is presented in this paper. The linear acutor is constructed as a linear stepper motor. However, to sustain both high accuracy and high speed for the position and speed control, A single-stack computer system is constructed and a special control algorithm is prescribed to controled the linear actuator continuously. In this paper, the nonlinear errors resulted from the magnetic saturation and the h...

  16. The relationship of high school graduation exams to graduation rates and SAT scores.

    Directory of Open Access Journals (Sweden)

    Gregory J. Marchant

    2005-01-01

    Full Text Available The current study examined the effect of high school graduation exams on states' graduation rates, states' aggregated SAT scores, and individual students' SAT scores. Three data sources were used: One source identified states requiring a standardized test for graduation; the NCES provided state aggregated data on graduation rates for the class of 2002; and the College Board provided its 2001 SAT database for all test-takers. After controlling for students' demographic characteristics (e.g., race, family education and income, GPA and class rank, regression analyses revealed that states requiring graduation exams had lower graduation rates and lower SAT scores. Individually, students from states requiring a graduation exam performed more poorly on the SAT than did students from states not requiring an exam. The impact of high stakes tests' on students' motivation to stay in school and on the teaching of critical thinking skills (tested by the SAT are discussed.

  17. High-accuracy C-14 measurements for atmospheric CO2 samples by AMS

    NARCIS (Netherlands)

    Meijer, H.A.J.; Pertuisot, M.H.; van der Plicht, J.

    2006-01-01

    In this paper, we investigate how to achieve high-accuracy radiocarbon measurements by accelerator mass spectrometry (ANIS) and present measurement series (performed on archived CO2) of (CO2)-C-14 between 1985 and 1991 for Point Barrow (Alaska) and the South Pole. We report in detail the measurement

  18. Further results on the operation of high-accuracy drift chambers

    NARCIS (Netherlands)

    Breskin, A.; Charpak, G.; Gabioud, B.; Sauli, F.; Trautner, N.

    Optimization of the working parameters in the drift chambers with adjustable electric fields permits stable operation and high accuracies. Full saturation of the drift velocity leads to remarkable improvements, namely a very linear space-time correlation for perpendicular tracks, and simple

  19. From journal to headline: the accuracy of climate science news in Danish high quality newspapers

    DEFF Research Database (Denmark)

    Vestergård, Gunver Lystbæk

    2011-01-01

    analysis to examine the accuracy of Danish high quality newspapers in quoting scientific publications from 1997 to 2009. Out of 88 articles, 46 contained inaccuracies though the majority was found to be insignificant and random. The study concludes that Danish broadsheet newspapers are ‘moderately...

  20. A 1-V 15 μW High-Accuracy Temperature Switch

    NARCIS (Netherlands)

    Schinkel, D.; Boer, de R.P.; Annema, A.J.; Tuijl, van A.J.M.

    2004-01-01

    A CMOS temperature switch with uncalibrated high accuracy is presented. The circuit is based on the classical CMOS bandgap reference structure, using parasitic PNPs and a PTAT multiplier. The circuit was designed in a standard digital 0.18 m CMOS process. The temperature switch has an in-designed hy

  1. From journal to headline: the accuracy of climate science news in Danish high quality newspapers

    DEFF Research Database (Denmark)

    Vestergård, Gunver Lystbæk

    2011-01-01

    analysis to examine the accuracy of Danish high quality newspapers in quoting scientific publications from 1997 to 2009. Out of 88 articles, 46 contained inaccuracies though the majority was found to be insignificant and random. The study concludes that Danish broadsheet newspapers are ‘moderately...

  2. Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement.

    Science.gov (United States)

    Schröter, S; Ihle, C; Elson, D W; Döbele, S; Stöckle, U; Ateschrang, A

    2016-11-01

    Medial opening wedge high tibial osteotomy (MOW HTO) is now a successful operation with a range of indications, requiring an individualised approach to the choice of intended correction. This manuscript introduces the concept of surgical accuracy as the absolute deviation of the achieved correction from the intended correction, where small values represent greater accuracy. Surgical accuracy is compared in a randomised controlled trial (RCT) between gap measurement and computer navigation groups. This was a prospective RCT conducted over 3 years of 120 consecutive patients with varus malalignment and medial compartment osteoarthritis, who underwent MOW HTO. All procedures were planned with digital software. Patients were randomly assigned into gap measurement or computer navigation groups. Coronal plane alignment was judged using the mechanical tibiofemoral angle (mTFA), before and after surgery. Absolute (positive) values were calculated for surgical accuracy in each individual case. There was no significant difference in the mean intended correction between groups. The achieved mTFA revealed a small under-correction in both groups. This was attributed to a failure to account for saw blade thickness (gap measurement) and over-compensation for weight bearing (computer navigation). Surgical accuracy was 1.7° ± 1.2° (gap measurement) compared to 2.1° ± 1.4° (computer navigation) without statistical significance. The difference in tibial slope increases of 2.7° ± 3.9° (gap measurement) and 2.1° ± 3.9° (computer navigation) had statistical significance (P osteotomy for individual cases. This work is clinically relevant because coronal surgical accuracy was not superior in either group. Therefore, the increased expense and surgical time associated with navigated MOW HTO is not supported, because meticulously conducted gap measurement yields equivalent surgical accuracy. I.

  3. PHOENIX: a scoring function for affinity prediction derived using high-resolution crystal structures and calorimetry measurements.

    Science.gov (United States)

    Tang, Yat T; Marshall, Garland R

    2011-02-28

    Binding affinity prediction is one of the most critical components to computer-aided structure-based drug design. Despite advances in first-principle methods for predicting binding affinity, empirical scoring functions that are fast and only relatively accurate are still widely used in structure-based drug design. With the increasing availability of X-ray crystallographic structures in the Protein Data Bank and continuing application of biophysical methods such as isothermal titration calorimetry to measure thermodynamic parameters contributing to binding free energy, sufficient experimental data exists that scoring functions can now be derived by separating enthalpic (ΔH) and entropic (TΔS) contributions to binding free energy (ΔG). PHOENIX, a scoring function to predict binding affinities of protein-ligand complexes, utilizes the increasing availability of experimental data to improve binding affinity predictions by the following: model training and testing using high-resolution crystallographic data to minimize structural noise, independent models of enthalpic and entropic contributions fitted to thermodynamic parameters assumed to be thermodynamically biased to calculate binding free energy, use of shape and volume descriptors to better capture entropic contributions. A set of 42 descriptors and 112 protein-ligand complexes were used to derive functions using partial least-squares for change of enthalpy (ΔH) and change of entropy (TΔS) to calculate change of binding free energy (ΔG), resulting in a predictive r2 (r(pred)2) of 0.55 and a standard error (SE) of 1.34 kcal/mol. External validation using the 2009 version of the PDBbind "refined set" (n = 1612) resulted in a Pearson correlation coefficient (R(p)) of 0.575 and a mean error (ME) of 1.41 pK(d). Enthalpy and entropy predictions were of limited accuracy individually. However, their difference resulted in a relatively accurate binding free energy. While the development of an accurate and applicable

  4. Impact of a high Edinburgh Postnatal Depression Scale score on obstetric and perinatal outcomes

    Science.gov (United States)

    Navaratne, Pathmila; Foo, Xin Y; Kumar, Sailesh

    2016-01-01

    The aim of this retrospective study was to characterise intrapartum and neonatal outcomes in women with an antenatally recorded Edinburgh Postnatal Depression Score (EPDS) ≤ 9 compared with women with a score of ≥12 at a major Australian tertiary maternity hospital. Women with scores ≥12 are at particularly high risk of major depressive symptomatology. There were 20512 (78.6%) women with a score ≤ 9 and 2708 (10.4%) had a score ≥ 12. Category 1 caesarean sections where there was immediate threat to life (maternal or fetal) were more common in women with EPDS scores ≥12 (5.2% vs. 4.3%, OR 1.24 95% CI 1.03–1.49, p = 0.024). Pre-term birth (birth weights birth (34.4% vs. 30.6%, p < 0.001) and neonatal death (0.48% vs. 0.13%, OR 2.52 95% CI 1.2–5.0, p < 0.001) were higher in babies of these women. These results suggest poorer intrapartum and neonatal outcomes for women with high EPDS scores. PMID:27658526

  5. A high-accuracy surgical augmented reality system using enhanced integral videography image overlay.

    Science.gov (United States)

    Zhang, Xinran; Chen, Guowen; Liao, Hongen

    2015-01-01

    Image guided surgery has been used in clinic to improve the surgery safety and accuracy. Augmented reality (AR) technique, which can provide intuitive image guidance, has been greatly evolved these years. As one promising approach of surgical AR systems, integral videography (IV) autostereoscopic image overlay has achieved accurate fusion of full parallax guidance into surgical scene. This paper describes an image enhanced high-accuracy IV overlay system. A flexible optical image enhancement system (IES) is designed to increase the resolution and quality of IV image. Furthermore, we introduce a novel IV rendering algorithm to promote the spatial accuracy with the consideration of distortion introduced by micro lens array. Preliminary experiments validated that the image accuracy and resolution are improved with the proposed methods. The resolution of the IV image could be promoted to 1 mm for a micro lens array with pitch of 2.32 mm and IES magnification value of 0.5. The relative deviation of accuracy in depth and lateral directions are -4.68 ± 0.83% and -9.01 ± 0.42%.

  6. Horizontal Positional Accuracy of Google Earth's High-Resolution Imagery Archive.

    Science.gov (United States)

    Potere, David

    2008-12-08

    Google Earth now hosts high-resolution imagery that spans twenty percent of the Earth's landmass and more than a third of the human population. This contemporary highresolution archive represents a significant, rapidly expanding, cost-free and largely unexploited resource for scientific inquiry. To increase the scientific utility of this archive, we address horizontal positional accuracy (georegistration) by comparing Google Earth with Landsat GeoCover scenes over a global sample of 436 control points located in 109 cities worldwide. Landsat GeoCover is an orthorectified product with known absolute positional accuracy of less than 50 meters root-mean-squared error (RMSE). Relative to Landsat GeoCover, the 436 Google Earth control points have a positional accuracy of 39.7 meters RMSE (error magnitudes range from 0.4 to 171.6 meters). The control points derived from satellite imagery have an accuracy of 22.8 meters RMSE, which is significantly more accurate than the 48 control-points based on aerial photography (41.3 meters RMSE; t-test p-value Google Earth highresolution imagery has a horizontal positional accuracy that is sufficient for assessing moderate-resolution remote sensing products across most of the world's peri-urban areas.

  7. Determining dynamical parameters of the Milky Way Galaxy based on high-accuracy radio astrometry

    Science.gov (United States)

    Honma, Mareki; Nagayama, Takumi; Sakai, Nobuyuki

    2015-08-01

    In this paper we evaluate how the dynamical structure of the Galaxy can be constrained by high-accuracy VLBI (Very Long Baseline Interferometry) astrometry such as VERA (VLBI Exploration of Radio Astrometry). We generate simulated samples of maser sources which follow the gas motion caused by a spiral or bar potential, with their distribution similar to those currently observed with VERA and VLBA (Very Long Baseline Array). We apply the Markov chain Monte Carlo analyses to the simulated sample sources to determine the dynamical parameter of the models. We show that one can successfully determine the initial model parameters if astrometric results are obtained for a few hundred sources with currently achieved astrometric accuracy. If astrometric data are available from 500 sources, the expected accuracy of R0 and Θ0 is ˜ 1% or higher, and parameters related to the spiral structure can be constrained by an error of 10% or with higher accuracy. We also show that the parameter determination accuracy is basically independent of the locations of resonances such as corotation and/or inner/outer Lindblad resonances. We also discuss the possibility of model selection based on the Bayesian information criterion (BIC), and demonstrate that BIC can be used to discriminate different dynamical models of the Galaxy.

  8. Techniques used in high-scoring and low-scoring 'Roche' vaults performed by elite male gymnasts.

    Science.gov (United States)

    Takei, Yoshiaki; Dunn, J Hubert; Blucker, Erik

    2003-07-01

    The 16 highest-scored Roche vaults (G1) performed during the 2000 Olympic Games were compared with those receiving the 16 lowest-scores (G2). A 16-mm motion picture camera operating at 100 Hz recorded the vaults during the competition. The results of t tests (p vertical force and backward horizontal force exerted by the board, greater change in the vertical velocity while on the board, and greater vertical velocity at board take-off, (b) comparable linear and angular motions in pre-flight, (c) smaller backward horizontal impulse exerted by the horse, smaller loss of the horizontal velocity while on the horse, and greater horizontal and vertical velocities at horse take-off, (d) greater height and larger horizontal distance of post-flight, (e) higher body mass centre at knee release, and (f) higher mass centre, greater normalised moment of inertia, and smaller vertical velocity at mat touchdown. Therefore, gymnasts and coaches should focus on sprinting the approach; blocking and pushing-off the take-off board rapidly and vigorously; departing the board with a large vertical velocity; exerting large downward vertical force and small forward horizontal force from the hand-stand position while on the horse; departing the horse with large horizontal and vertical velocities; and completing the majority of the double salto forward near the peak of trajectory and releasing the knees above the top of the horse to prepare for a controlled landing.

  9. Association between BVAB1 and high Nugent scores among women with bacterial vaginosis

    Science.gov (United States)

    Muzny, Christina A.; Sunesara, Imran R.; Griswold, Michael E.; Kumar, Ranjit; Lefkowitz, Elliot J.; Mena, Leandro A.; Schwebke, Jane R.; Martin, David H.; Swiatlo, Edwin

    2015-01-01

    As part of a larger study using 454 pyrosequencing to investigate the vaginal microbiota of women with bacterial vaginosis (BV), we found an association between a novel BV-associated bacterium (BVAB1) and high Nugent scores and propose that BVAB1 is the curved Gram-negative rod traditionally identified as Mobiluncus spp. in vaginal Gram stains. PMID:25262105

  10. Allocation of nonstandard livers to transplant candidates with high MELD scores: Should this practice be continued?

    Science.gov (United States)

    Avolio, A W; Agnes, S; Gasbarrini, A; Barbarino, R; Nure, E; Siciliano, M; Barone, M; Castagneto, M

    2006-12-01

    MELD and PELD scores of 255 consecutive grafts were calculated (236 adult cases and 19 pediatric cases). No correction for the etiology of liver disease was performed. Retransplants were excluded. Three categories of patients were identified: low MELD (scores or =25, n = 35). Grafts were categorized according to donor quality: standard livers (n = 199), vs nonstandard livers (n = 56). Nonstandard livers were identified by age > or =60, or at least by two of the following conditions: severe hemodynamic instability, ultrasound evidence of steatosis, natriemia > or =155 mEq/L, ICU stay >7 days, liver trauma, protracted anoxia as cause of brain death, transaminases levels x 4. In standard livers, the 12-month graft survival (GS) for low, intermediate, and high MELD classes were 88%, 74%, and 77%, respectively. In nonstandard livers, the 12-month GS for the low, intermediate, and high MELD classes were 84%, 55%, and 44%, respectively; differences between low MELD class and both intermediate and high MELD classes were significant (P < .05). Cox regression analysis of all cases identified the following parameters as independent predictors of GS: donor status; donor age; and recipient creatinine. The highest correlation with GS was found using donor age and recipient creatinine as covariates. In standard livers no variable was able to predict GS. In nonstandard livers the MELD-PELD score was the unique variable able to predict GS. We suggest avoiding the use of nonstandard livers for patients with high MELD scores.

  11. Association between BVAB1 and high Nugent scores among women with bacterial vaginosis.

    Science.gov (United States)

    Muzny, Christina A; Sunesara, Imran R; Griswold, Michael E; Kumar, Ranjit; Lefkowitz, Elliot J; Mena, Leandro A; Schwebke, Jane R; Martin, David H; Swiatlo, Edwin

    2014-12-01

    As part of a larger study using 454 pyrosequencing to investigate the vaginal microbiota of women with bacterial vaginosis (BV), we found an association between a novel BV-associated bacterium (BVAB1) and high Nugent scores and propose that BVAB1 is the curved Gram-negative rod traditionally identified as Mobiluncus spp. in vaginal Gram stains.

  12. Two-step Structural Design of Mesh Antennas for High Beam Pointing Accuracy

    Science.gov (United States)

    Zhang, Shuxin; Du, Jingli; Wang, Wei; Zhang, Xinghua; Zong, Yali

    2017-05-01

    A well-designed reflector surface with high beam pointing accuracy in electromagnetic performance is of practical significance to the space application of cable mesh reflector antennas. As for space requirements, circular polarizations are widely used in spaceborne antennas, which usually lead to a beam shift for offset reflectors and influence the beam pointing accuracy. A two-step structural design procedure is proposed to overcome the beam squint phenomenon for high beam pointing accuracy design of circularly polarized offset cable mesh reflectors. A simple structural optimal design and an integrated structural electromagnetic optimization are combined to alleviate the beam squint effect of circular polarizations. It is implemented by cable pretension design and adjustment to shape the offset cable mesh surface. Besides, in order to increase the efficiency of integrated optimization, an update Broyden-Fletcher-Goldfarb-Shanno (BFGS) Hessian matrix is employed in the optimization iteration with sequential quadratic programming. A circularly polarized offset cable mesh reflector is utilized to show the feasibility and effectiveness of the proposed procedure. A high beam pointing accuracy in order of 0.0001º of electromagnetic performance is achieved.

  13. Decreased fucosylated PSA as a urinary marker for high Gleason score prostate cancer

    Science.gov (United States)

    Fujita, Kazutoshi; Hayashi, Takuji; Matsuzaki, Kyosuke; Nakata, Wataru; Masuda, Mika; Kawashima, Atsunari; Ujike, Takeshi; Nagahara, Akira; Tsuchiya, Mutsumi; Kobayashi, Yuka; Nojima, Satoshi; Uemura, Motohide; Morii, Eiichi; Miyoshi, Eiji; Nonomura, Norio

    2016-01-01

    Fucosylation is an important oligosaccharide modification associated with cancer and inflammation. We investigated whether urinary fucosylated PSA (Fuc-PSA) levels could be used for the detection of high Gleason score prostate cancer. Urine samples were collected from men with abnormal digital rectal examination findings or elevated serum PSA levels, before prostate biopsy. Lectin-antibody ELISA was used to quantify the Lewis-type or core-type fucosylated PSA (PSA-AAL) and core-type fucosylated PSA (PSA-PhoSL) in the urine samples. Both types of urinary Fuc-PSA were significantly decreased in the men with prostate cancer compared with the men whose biopsies were negative for cancer (P = 0.026 and P biopsy specimens (P = 0.001 and P < 0.001, respectively). Multivariate analysis showed that PSA density, urinary PSA-AAL, and urinary PSA-PhoSL were independent predictors of high Gleason score prostate cancer. The area under the receiver-operator characteristic curve (AUC) value for the prediction of cancers of Gleason score ≥ 7 was 0.69 for urinary PSA-AAL and 0.72 for urinary PSA-PhoSL. In contrast, the AUC value was 0.59 for serum PSA, 0.63 for PSA density, and 0.58 for urinary PSA. In conclusion, a decreased urinary Fuc-PSA level is a potential marker for the detection of high Gleason score prostate cancer. PMID:27494861

  14. The Impact of Ionospheric Disturbances on High Accuracy Positioning in Brazil

    Science.gov (United States)

    Yang, L.; Park, J.; Susnik, A.; Aquino, M. H.; Dodson, A.

    2013-12-01

    High positioning accuracy is a key requirement to a number of applications with a high economic impact, such as precision agriculture, surveying, geodesy, land management, off-shore operations. Global Navigation Satellite Systems (GNSS) carrier phase measurement based techniques, such as Real Time Kinematic (RTK), Network-RTK (NRTK) and Precise Point Positioning (PPP), have played an important role in providing centimetre-level positioning accuracy, and become the core of the above applications. However these techniques are especially sensitive to ionospheric perturbations, in particular scintillation. Brazil sits in one of the most affected regions of the Earth and can be regarded as a test-bed for scenarios of the severe ionospheric condition. Over the Brazilian territory, the ionosphere behaves in a considerably unpredictable way and scintillation activity is very prominent, occurring especially after sunset hours. NRTK services may not be able to provide satisfactory accuracy, or even continuous positioning during strong scintillation periods. CALIBRA (Countering GNSS high Accuracy applications Limitations due to Ionospheric disturbances in BRAzil) started in late 2012 and is a project funded by the GSA (European GNSS Agency) and the European Commission under the Framework Program 7 to deliver improvements on carrier phase based high accuracy algorithms and their implementation in GNSS receivers, aiming to counter the adverse ionospheric effects over Brazil. As the first stage of this project, the ionospheric disturbances, which affect the applications of RTK, NRTK or PPP, are characterized. Typical problems include degraded positioning accuracy, difficulties in ambiguity fixing, NRTK network interpolation errors, long PPP convergence time etc. It will identify how GNSS observables and existing algorithms are degraded by ionosphere related phenomena, evaluating the impact on positioning techniques in terms of accuracy, integrity and availability. Through the

  15. Hybrid head-tracker being examined for the high-accuracy attack rotorcraft market

    Science.gov (United States)

    Blanton, Buddy

    2002-08-01

    The need for the helmet-mounted display (HMD) to present flight, navigation, and weapon information in the pilot's line-of-sight has continued to rise as helicopter missions increase in complexity. To obtain spatial correlation of the direction of the head line-of-sight and pilotage imagery generated from helicopter-mounted sensors, it is necessary to slave the sensors to the head motion. To accomplish this task, a head-tracking system (HTS) must be incorporated into the HMD. There are a variety of techniques that could be applied for locating the position and attitude of a helmet-mounted display. Regardless of the technology, an HTS must provide defined measurements of accuracy. System parameters include motion box size, angular range, pointing angle accuracy, pointing angle resolution, update rate, and slew rate. This paper focuses on a hybrid tracker implementation in which a combination of optical and inertial tracking using strap-down gyros is preferred. Specifically, this tracker implementation is being examined for the high-accuracy attack rotorcraft market which requires a high degree of accuracy. The performance and resultant cost of the tracker components are determined by the specific needs of the intended application. The paper will also indicate how the various requirements drive the cost, configuration, and performance of the resultant hybrid head-tracker.

  16. Literature survey of high-impact journals revealed reporting weaknesses in abstracts of diagnostic accuracy studies.

    Science.gov (United States)

    Korevaar, Daniël A; Cohen, Jérémie F; Hooft, Lotty; Bossuyt, Patrick M M

    2015-06-01

    Informative journal abstracts are crucial for the identification and initial appraisal of studies. We aimed to evaluate the informativeness of abstracts of diagnostic accuracy studies. PubMed was searched for reports of studies that had evaluated the diagnostic accuracy of a test against a clinical reference standard, published in 12 high-impact journals in 2012. Two reviewers independently evaluated the information contained in included abstracts using 21 items deemed important based on published guidance for adequate reporting and study quality assessment. We included 103 abstracts. Crucial information on study population, setting, patient sampling, and blinding as well as confidence intervals around accuracy estimates were reported in items per abstract was 10.1 of 21 (standard deviation 2.2). The mean number of reported items was significantly lower for multiple-gate (case-control type) studies, in reports in specialty journals, and for studies with smaller sample sizes and lower abstract word counts. No significant differences were found between studies evaluating different types of tests. Many abstracts of diagnostic accuracy study reports in high-impact journals are insufficiently informative. Developing guidelines for such abstracts could help the transparency and completeness of reporting. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. About accuracy of the discrimination parameter estimation for the dual high-energy method

    Science.gov (United States)

    Osipov, S. P.; Chakhlov, S. V.; Osipov, O. S.; Shtein, A. M.; Strugovtsev, D. V.

    2015-04-01

    A set of the mathematical formulas to estimate the accuracy of discrimination parameters for two implementations of the dual high energy method - by the effective atomic number and by the level lines is given. The hardware parameters which influenced on the accuracy of the discrimination parameters are stated. The recommendations to form the structure of the high energy X-ray radiation impulses are formulated. To prove the applicability of the proposed procedure there were calculated the statistical errors of the discrimination parameters for the cargo inspection system of the Tomsk polytechnic university on base of the portable betatron MIB-9. The comparison of the experimental estimations and the theoretical ones of the discrimination parameter errors was carried out. It proved the practical applicability of the algorithm to estimate the discrimination parameter errors for the dual high energy method.

  18. High accuracy digital aging monitor based on PLL-VCO circuit

    Science.gov (United States)

    Yuejun, Zhang; Zhidi, Jiang; Pengjun, Wang; Xuelong, Zhang

    2015-01-01

    As the manufacturing process is scaled down to the nanoscale, the aging phenomenon significantly affects the reliability and lifetime of integrated circuits. Consequently, the precise measurement of digital CMOS aging is a key aspect of nanoscale aging tolerant circuit design. This paper proposes a high accuracy digital aging monitor using phase-locked loop and voltage-controlled oscillator (PLL-VCO) circuit. The proposed monitor eliminates the circuit self-aging effect for the characteristic of PLL, whose frequency has no relationship with circuit aging phenomenon. The PLL-VCO monitor is implemented in TSMC low power 65 nm CMOS technology, and its area occupies 303.28 × 298.94 μm2. After accelerating aging tests, the experimental results show that PLL-VCO monitor improves accuracy about high temperature by 2.4% and high voltage by 18.7%.

  19. High accuracy acoustic relative humidity measurement in duct flow with air.

    Science.gov (United States)

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

  20. High Mass Accuracy and High Mass Resolving Power FT-ICR Secondary Ion Mass Spectrometry for Biological Tissue Imaging

    CERN Document Server

    Smith, Donald F; Leach, Franklin E; Robinson, Errol W; Paša-Tolić, Ljiljana; Heeren, Ron M A

    2013-01-01

    Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the sub-micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for elemental formula assignment based on exact mass measurement. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissu...

  1. Results of error correction techniques applied on two high accuracy coordinate measuring machines

    Energy Technology Data Exchange (ETDEWEB)

    Pace, C.; Doiron, T.; Stieren, D.; Borchardt, B.; Veale, R. (Sandia National Labs., Albuquerque, NM (USA); National Inst. of Standards and Technology, Gaithersburg, MD (USA))

    1990-01-01

    The Primary Standards Laboratory at Sandia National Laboratories (SNL) and the Precision Engineering Division at the National Institute of Standards and Technology (NIST) are in the process of implementing software error correction on two nearly identical high-accuracy coordinate measuring machines (CMMs). Both machines are Moore Special Tool Company M-48 CMMs which are fitted with laser positioning transducers. Although both machines were manufactured to high tolerance levels, the overall volumetric accuracy was insufficient for calibrating standards to the levels both laboratories require. The error mapping procedure was developed at NIST in the mid 1970's on an earlier but similar model. The error mapping procedure was originally very complicated and did not make any assumptions about the rigidness of the machine as it moved, each of the possible error motions was measured at each point of the error map independently. A simpler mapping procedure was developed during the early 1980's which assumed rigid body motion of the machine. This method has been used to calibrate lower accuracy machines with a high degree of success and similar software correction schemes have been implemented by many CMM manufacturers. The rigid body model has not yet been used on highly repeatable CMMs such as the M48. In this report we present early mapping data for the two M48 CMMs. The SNL CMM was manufactured in 1985 and has been in service for approximately four years, whereas the NIST CMM was delivered in early 1989. 4 refs., 5 figs.

  2. RNA secondary structure modeling at consistent high accuracy using differential SHAPE.

    Science.gov (United States)

    Rice, Greggory M; Leonard, Christopher W; Weeks, Kevin M

    2014-06-01

    RNA secondary structure modeling is a challenging problem, and recent successes have raised the standards for accuracy, consistency, and tractability. Large increases in accuracy have been achieved by including data on reactivity toward chemical probes: Incorporation of 1M7 SHAPE reactivity data into an mfold-class algorithm results in median accuracies for base pair prediction that exceed 90%. However, a few RNA structures are modeled with significantly lower accuracy. Here, we show that incorporating differential reactivities from the NMIA and 1M6 reagents--which detect noncanonical and tertiary interactions--into prediction algorithms results in highly accurate secondary structure models for RNAs that were previously shown to be difficult to model. For these RNAs, 93% of accepted canonical base pairs were recovered in SHAPE-directed models. Discrepancies between accepted and modeled structures were small and appear to reflect genuine structural differences. Three-reagent SHAPE-directed modeling scales concisely to structurally complex RNAs to resolve the in-solution secondary structure analysis problem for many classes of RNA.

  3. A fast and high accuracy numerical simulation algorithm of the polymer spherulite at the mesoscale Level

    Science.gov (United States)

    Liu, Yongzhi; Geng, Tie; (Tom Turng, Lih-Sheng; Liu, Chuntai; Cao, Wei; Shen, Changyu

    2017-09-01

    In the multiscale numerical simulation of polymer crystallization during the processing period, flow and temperature of the polymer melt are simulated on the macroscale level, while nucleation and growth of the spherulite are simulated at the mesoscale level. As a part of the multiscale simulation, the meso-simulation requires a fast solving speed because the meso-simulation software must be run several times in every macro-element at each macro-step. Meanwhile, the accuracy of the calculation results is also very important. It is known that the simulation geometry of crystallization includes planar (2D) and three-dimensional space (3D). The 3D calculations are more accurate but more expensive because of the long CPU time consumed. On the contrary, 2D calculations are always much faster but lower in accuracy. To reach the desirable speed and high accuracy at the same time, an algorithm is presented, in which the Delesse law coupled with the Monte Carlo method and pixel method are employed to simulate the nucleation, growth, and impingement of the polymer spherulite at the mesoscale level. Based on this algorithm, a software is developed with the Visual C++ language, and its numerical examples’ results prove that the solving speed of this algorithm is as fast as the 2D classical simulation and the calculation accuracy is at the same level as the 3D simulation.

  4. High Accuracy Gravitational Waveforms from Black Hole Binary Inspirals Using OpenCL

    CERN Document Server

    McKennon, Justin; Khanna, Gaurav

    2012-01-01

    There is a strong need for high-accuracy and efficient modeling of extreme-mass-ratio binary black hole systems because these are strong sources of gravitational waves that would be detected by future observatories. In this article, we present sample results from our Teukolsky EMRI code: a time-domain Teukolsky equation solver (a linear, hyperbolic, partial differential equation solver using finite-differencing), that takes advantage of several mathematical and computational enhancements to efficiently generate long-duration and high-accuracy EMRI waveforms. We emphasize here the computational advances made in the context of this code. Currently there is considerable interest in making use of many-core processor architectures, such as Nvidia and AMD graphics processing units (GPUs) for scientific computing. Our code uses the Open Computing Language (OpenCL) for taking advantage of the massive parallelism offered by modern GPU architectures. We present the performance of our Teukolsky EMRI code on multiple mod...

  5. On the role of marginal confounder prevalence - implications for the high-dimensional propensity score algorithm.

    Science.gov (United States)

    Schuster, Tibor; Pang, Menglan; Platt, Robert W

    2015-09-01

    The high-dimensional propensity score algorithm attempts to improve control of confounding in typical treatment effect studies in pharmacoepidemiology and is increasingly being used for the analysis of large administrative databases. Within this multi-step variable selection algorithm, the marginal prevalence of non-zero covariate values is considered to be an indicator for a count variable's potential confounding impact. We investigate the role of the marginal prevalence of confounder variables on potentially caused bias magnitudes when estimating risk ratios in point exposure studies with binary outcomes. We apply the law of total probability in conjunction with an established bias formula to derive and illustrate relative bias boundaries with respect to marginal confounder prevalence. We show that maximum possible bias magnitudes can occur at any marginal prevalence level of a binary confounder variable. In particular, we demonstrate that, in case of rare or very common exposures, low and high prevalent confounder variables can still have large confounding impact on estimated risk ratios. Covariate pre-selection by prevalence may lead to sub-optimal confounder sampling within the high-dimensional propensity score algorithm. While we believe that the high-dimensional propensity score has important benefits in large-scale pharmacoepidemiologic studies, we recommend omitting the prevalence-based empirical identification of candidate covariates. Copyright © 2015 John Wiley & Sons, Ltd.

  6. The synergistic value of focus score and IgA% score of sublabial salivary gland biopsy for the accuracy of the diagnosis of Sjögren's syndrome: a 10-year comparison

    NARCIS (Netherlands)

    Zandbelt, M.; Wentink, J.R.M.; Wilde, P.C.M. de; Damme, P.A. van; Putte, L.B.A. van de; Hoogen, F.H.J. van den

    2002-01-01

    OBJECTIVE: Increasing the accuracy of the diagnosis of Sjogren's syndrome (SS) by placing emphasis on objective findings such as the presence of anti-Ro and anti-La autoantibodies and abnormal salivary gland tissue (SGT) histology is a current issue. In order to obtain optimal disease sensitivity an

  7. Risk prediction score for severe high altitude illness: a cohort study.

    Directory of Open Access Journals (Sweden)

    Florence Canouï-Poitrine

    Full Text Available Risk prediction of acute mountain sickness, high altitude (HA pulmonary or cerebral edema is currently based on clinical assessment. Our objective was to develop a risk prediction score of Severe High Altitude Illness (SHAI combining clinical and physiological factors. Study population was 1017 sea-level subjects who performed a hypoxia exercise test before a stay at HA. The outcome was the occurrence of SHAI during HA exposure. Two scores were built, according to the presence (PRE, n = 537 or absence (ABS, n = 480 of previous experience at HA, using multivariate logistic regression. Calibration was evaluated by Hosmer-Lemeshow chisquare test and discrimination by Area Under ROC Curve (AUC and Net Reclassification Index (NRI.The score was a linear combination of history of SHAI, ventilatory and cardiac response to hypoxia at exercise, speed of ascent, desaturation during hypoxic exercise, history of migraine, geographical location, female sex, age under 46 and regular physical activity. In the PRE/ABS groups, the score ranged from 0 to 12/10, a cut-off of 5/5.5 gave a sensitivity of 87%/87% and a specificity of 82%/73%. Adding physiological variables via the hypoxic exercise test improved the discrimination ability of the models: AUC increased by 7% to 0.91 (95%CI: 0.87-0.93 and 17% to 0.89 (95%CI: 0.85-0.91, NRI was 30% and 54% in the PRE and ABS groups respectively. A score computed with ten clinical, environmental and physiological factors accurately predicted the risk of SHAI in a large cohort of sea-level residents visiting HA regions.

  8. Cavity ring-down technique for measurement of reflectivity of high reflectivity mirrors with high accuracy

    Indian Academy of Sciences (India)

    G Sridhar; Sandeep K Agarwalla; Sunita Singh; L M Gantayet

    2010-12-01

    A simple, accurate and reliable method for measuring the reflectivity of laser-grade mirrors ( > 99.5 %) based on cavity ring-down (CRD) technique has been success-fully demonstrated in our laboratory using a pulsed Nd:YAG laser. A fast photomultiplier tube with an oscilloscope was used to detect and analyse the CRD signal. The cavity decay times were measured for three cavities formed by a combination of three mirror pairs. The absolute reflectivities 1, 2, 3 were determined to be 99.94%, 99.63%, 99.52% at normal incidence. The reflectivity of mirrors is measured to an accuracy of 0.01%.

  9. Predictors of high score patient-reported barriers to controlling cancer pain: a preliminary report.

    Science.gov (United States)

    Kwon, Jung Hye; Oh, Sung Yong; Chisholm, Gary; Lee, Jung-Ae; Lee, Jae Jin; Park, Keon Woo; Nam, Seung-Hyun; Song, Hun Ho; Lee, Keehyun; Zang, Dae Young; Kim, Ho Young; Choi, Dae Ro; Kim, Hyo Jung; Kim, Jung Han; Jung, Joo Young; Jang, Geundoo; Kim, Hyeong Su; Won, Ji Yun; Bruera, Eduardo

    2013-04-01

    Pain is one of the most common and devastating symptoms in cancer patients, and misunderstandings on the patient's part can cause major obstacles in pain management. We evaluated factors associated with patient's high barrier score to managing cancer-associated pain by having 201 patients complete the Korean Barriers Questionnaire II, the Brief Pain Inventory--Korean, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30, and the Korean Beck Depression Inventory. The Pain Management Index (PMI) was also assessed. The patients were from nine oncology clinics in university hospitals and a veterans' hospital in South Korea. The median pain score (0-10 scale) was 4, with a median percentage of pain improvement during the last 24 h of 70 %. A total of 150 patients (75 %) received strong opioids, and 177 (88 %) achieved adequate analgesia (positive PMI). Mean scores ± SD for the Barriers Questionnaire II ranged from 1.5 ± 1 to 2.8 ± 1.1, with the harmful effects subscale the highest. In the multiple regression model, depression was significantly associated with total barrier score to pain management (p Management of cancer pain should include screening for depression, and management of depression could reduce patient-reported barriers to pain management.

  10. A Smart High Accuracy Silicon Piezoresistive Pressure Sensor Temperature Compensation System

    Directory of Open Access Journals (Sweden)

    Guanwu Zhou

    2014-07-01

    Full Text Available Theoretical analysis in this paper indicates that the accuracy of a silicon piezoresistive pressure sensor is mainly affected by thermal drift, and varies nonlinearly with the temperature. Here, a smart temperature compensation system to reduce its effect on accuracy is proposed. Firstly, an effective conditioning circuit for signal processing and data acquisition is designed. The hardware to implement the system is fabricated. Then, a program is developed on LabVIEW which incorporates an extreme learning machine (ELM as the calibration algorithm for the pressure drift. The implementation of the algorithm was ported to a micro-control unit (MCU after calibration in the computer. Practical pressure measurement experiments are carried out to verify the system’s performance. The temperature compensation is solved in the interval from −40 to 85 °C. The compensated sensor is aimed at providing pressure measurement in oil-gas pipelines. Compared with other algorithms, ELM acquires higher accuracy and is more suitable for batch compensation because of its higher generalization and faster learning speed. The accuracy, linearity, zero temperature coefficient and sensitivity temperature coefficient of the tested sensor are 2.57% FS, 2.49% FS, 8.1 × 10−5/°C and 29.5 × 10−5/°C before compensation, and are improved to 0.13%FS, 0.15%FS, 1.17 × 10−5/°C and 2.1 × 10−5/°C respectively, after compensation. The experimental results demonstrate that the proposed system is valid for the temperature compensation and high accuracy requirement of the sensor.

  11. High Mass Accuracy and High Mass Resolving Power FT-ICR Secondary Ion Mass Spectrometry for Biological Tissue Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Donald F.; Kiss, Andras; Leach, Franklin E.; Robinson, Errol W.; Pasa-Tolic, Ljiljana; Heeren, Ronald M.

    2013-07-01

    Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for exact mass elemental formula assignment. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissue was measured with 150 μm spatial resolution (75 μm primary ion spot size) with mass resolving power (m/Δm50%) of 67,500 (at m/z 750) and root-mean-square measurement accuracy less than two parts-per-million for intact phospholipids, small molecules and fragments. For the first time, ultra-high mass resolving power SIMS has been demonstrated, with m/Δm50% > 3,000,000. Higher spatial resolution capabilities of the platform were tested at a spatial resolution of 20 μm. The results represent order of magnitude improvements in mass resolving power and mass measurement accuracy for SIMS imaging and the promise of the platform for ultra-high mass resolving power and high spatial resolution imaging.

  12. Accuracy of GPS devices for measuring high-intensity running in field-based team sports.

    Science.gov (United States)

    Rampinini, E; Alberti, G; Fiorenza, M; Riggio, M; Sassi, R; Borges, T O; Coutts, A J

    2015-01-01

    We compared the accuracy of 2 GPS systems with different sampling rates for the determination of distances covered at high-speed and metabolic power derived from a combination of running speed and acceleration. 8 participants performed 56 bouts of shuttle intermittent running wearing 2 portable GPS devices (SPI-Pro, GPS-5 Hz and MinimaxX, GPS-10 Hz). The GPS systems were compared with a radar system as a criterion measure. The variables investigated were: total distance (TD), high-speed distance (HSR>4.17 m·s(-1)), very high-speed distance (VHSR>5.56 m·s(-1)), mean power (Pmean), high metabolic power (HMP>20 W·kg(-1)) and very high metabolic power (VHMP>25 W·kg(-1)). GPS-5 Hz had low error for TD (2.8%) and Pmean (4.5%), while the errors for the other variables ranged from moderate to high (7.5-23.2%). GPS-10 Hz demonstrated a low error for TD (1.9%), HSR (4.7%), Pmean (2.4%) and HMP (4.5%), whereas the errors for VHSR (10.5%) and VHMP (6.2%) were moderate. In general, GPS accuracy increased with a higher sampling rate, but decreased with increasing speed of movement. Both systems could be used for calculating TD and Pmean, but they cannot be used interchangeably. Only GPS-10 Hz demonstrated a sufficient level of accuracy for quantifying distance covered at higher speeds or time spent at very high power. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Making high-accuracy null depth measurements for the LBTI exozodi survey

    Science.gov (United States)

    Mennesson, Bertrand; Defrère, Denis; Nowak, Matthias; Hinz, Philip; Millan-Gabet, Rafael; Absil, Olivier; Bailey, Vanessa; Bryden, Geoffrey; Danchi, William; Kennedy, Grant M.; Marion, Lindsay; Roberge, Aki; Serabyn, Eugene; Skemer, Andy J.; Stapelfeldt, Karl; Weinberger, Alycia J.; Wyatt, Mark

    2016-08-01

    The characterization of exozodiacal light emission is both important for the understanding of planetary systems evolution and for the preparation of future space missions aiming to characterize low mass planets in the habitable zone of nearby main sequence stars. The Large Binocular Telescope Interferometer (LBTI) exozodi survey aims at providing a ten-fold improvement over current state of the art, measuring dust emission levels down to a typical accuracy of 12 zodis per star, for a representative ensemble of 30+ high priority targets. Such measurements promise to yield a final accuracy of about 2 zodis on the median exozodi level of the targets sample. Reaching a 1 σ measurement uncertainty of 12 zodis per star corresponds to measuring interferometric cancellation ("null") levels, i.e visibilities at the few 100 ppm uncertainty level. We discuss here the challenges posed by making such high accuracy mid-infrared visibility measurements from the ground and present the methodology we developed for achieving current best levels of 500 ppm or so. We also discuss current limitations and plans for enhanced exozodi observations over the next few years at LBTI.

  14. Optical System Error Analysis and Calibration Method of High-Accuracy Star Trackers

    Directory of Open Access Journals (Sweden)

    Zheng You

    2013-04-01

    Full Text Available The star tracker is a high-accuracy attitude measurement device widely used in spacecraft. Its performance depends largely on the precision of the optical system parameters. Therefore, the analysis of the optical system parameter errors and a precise calibration model are crucial to the accuracy of the star tracker. Research in this field is relatively lacking a systematic and universal analysis up to now. This paper proposes in detail an approach for the synthetic error analysis of the star tracker, without the complicated theoretical derivation. This approach can determine the error propagation relationship of the star tracker, and can build intuitively and systematically an error model. The analysis results can be used as a foundation and a guide for the optical design, calibration, and compensation of the star tracker. A calibration experiment is designed and conducted. Excellent calibration results are achieved based on the calibration model. To summarize, the error analysis approach and the calibration method are proved to be adequate and precise, and could provide an important guarantee for the design, manufacture, and measurement of high-accuracy star trackers.

  15. Scoring clinical signs can help diagnose canine visceral leishmaniasis in a highly endemic area in Brazil

    Science.gov (United States)

    da Silva, Kleverton Ribeiro; de Mendonça, Vitor Rosa Ramos; Silva, Kellen Matuzzy; do Nascimento, Leopoldo Fabrício Marçal; Mendes-Sousa, Antonio Ferreira; de Pinho, Flaviane Alves; Barral-Netto, Manoel; Barral, Aldina Maria Prado; Cruz, Maria do Socorro Pires e

    2017-01-01

    Canine visceral leishmaniasis (CVL) diagnosis is still a challenge in endemic areas with limited diagnostic resources. This study proposes a score with the potential to distinguish positive CVL cases from negative ones. We studied 265 dogs that tested positive for CVL on ELISA and parasitological tests. A score ranging between 0 and 19 was recorded on the basis of clinical signs. Dogs with CVL had an overall higher positivity of the majority of clinical signs than did dogs without CVL or with ehrlichiosis. Clinical signs such as enlarged lymph nodes (83.93%), muzzle/ear lesions (55.36%), nutritional status (51.79%), bristle condition (57.14%), pale mucosal colour (48.21%), onychogryphosis (58.93%), skin lesion (39.28%), bleeding (12.50%), muzzle depigmentation (41.07%), alopecia (39.29%), blepharitis (21.43%), and keratoconjunctivitis (42.86%) were more frequent in dogs with CVL than in dogs with ehrlichiosis or without CVL. Moreover, the clinical score increased according to the positivity of all diagnostic tests (ELISA, p < 0.001; parasite culture, p = 0.0021; and smear, p = 0.0003). Onychogryphosis (long nails) [odds ratio (OR): 3.529; 95% confidence interval (CI): 1.832-6.796; p < 0.001], muzzle depigmentation (OR: 4.651; 95% CI: 2.218-9.750; p < 0.001), and keratoconjunctivitis (OR: 5.400; 95% CI: 2.549-11.441; p < 0.001) were highly associated with CVL. Interestingly, a score cut-off value ≥ 6 had an area under the curve of 0.717 (p < 0.0001), sensitivity of 60.71%, and specificity of 73.64% for CVL diagnosis. The clinical sign-based score for CVL diagnosis suggested herein can help veterinarians reliably identify dogs with CVL in endemic areas with limited diagnostic resources. PMID:28076469

  16. High Accuracy Attitude Control System Design for Satellite with Flexible Appendages

    Directory of Open Access Journals (Sweden)

    Wenya Zhou

    2014-01-01

    Full Text Available In order to realize the high accuracy attitude control of satellite with flexible appendages, attitude control system consisting of the controller and structural filter was designed. When the low order vibration frequency of flexible appendages is approximating the bandwidth of attitude control system, the vibration signal will enter the control system through measurement device to bring impact on the accuracy or even the stability. In order to reduce the impact of vibration of appendages on the attitude control system, the structural filter is designed in terms of rejecting the vibration of flexible appendages. Considering the potential problem of in-orbit frequency variation of the flexible appendages, the design method for the adaptive notch filter is proposed based on the in-orbit identification technology. Finally, the simulation results are given to demonstrate the feasibility and effectiveness of the proposed design techniques.

  17. High-accuracy determination of the neutron flux at n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Barbagallo, M.; Colonna, N.; Mastromarco, M.; Meaze, M.; Tagliente, G.; Variale, V. [Sezione di Bari, INFN, Bari (Italy); Guerrero, C.; Andriamonje, S.; Boccone, V.; Brugger, M.; Calviani, M.; Cerutti, F.; Chin, M.; Ferrari, A.; Kadi, Y.; Losito, R.; Versaci, R.; Vlachoudis, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Tsinganis, A. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); National Technical University of Athens (NTUA), Athens (Greece); Tarrio, D.; Duran, I.; Leal-Cidoncha, E.; Paradela, C. [Universidade de Santiago de Compostela, Santiago (Spain); Altstadt, S.; Goebel, K.; Langer, C.; Reifarth, R.; Schmidt, S.; Weigand, M. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (Germany); Andrzejewski, J.; Marganiec, J.; Perkowski, J. [Uniwersytet Lodzki, Lodz (Poland); Audouin, L.; Leong, L.S.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Becares, V.; Cano-Ott, D.; Garcia, A.R.; Gonzalez-Romero, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Becvar, F.; Krticka, M.; Kroll, J.; Valenta, S. [Charles University, Prague (Czech Republic); Belloni, F.; Fraval, K.; Gunsing, F.; Lampoudis, C.; Papaevangelou, T. [Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Berthoumieux, E.; Chiaveri, E. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Billowes, J.; Ware, T.; Wright, T. [University of Manchester, Manchester (United Kingdom); Bosnar, D.; Zugec, P. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Calvino, F.; Cortes, G.; Gomez-Hornillos, M.B.; Riego, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Carrapico, C.; Goncalves, I.F.; Sarmento, R.; Vaz, P. [Universidade Tecnica de Lisboa, Instituto Tecnologico e Nuclear, Instituto Superior Tecnico, Lisboa (Portugal); Cortes-Giraldo, M.A.; Praena, J.; Quesada, J.M.; Sabate-Gilarte, M. [Universidad de Sevilla, Sevilla (Spain); Diakaki, M.; Karadimos, D.; Kokkoris, M.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Domingo-Pardo, C.; Giubrone, G.; Tain, J.L. [CSIC-Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Kivel, N.; Schumann, D.; Steinegger, P. [Paul Scherrer Institut, Villigen PSI (Switzerland); Dzysiuk, N.; Mastinu, P.F. [Laboratori Nazionali di Legnaro, INFN, Rome (Italy); Eleftheriadis, C.; Manousos, A. [Aristotle University of Thessaloniki, Thessaloniki (Greece); Ganesan, S.; Gurusamy, P.; Saxena, A. [Bhabha Atomic Research Centre (BARC), Mumbai (IN); Griesmayer, E.; Jericha, E.; Leeb, H. [Technische Universitaet Wien, Atominstitut, Wien (AT); Hernandez-Prieto, A. [European Organization for Nuclear Research (CERN), Geneva (CH); Universitat Politecnica de Catalunya, Barcelona (ES); Jenkins, D.G.; Vermeulen, M.J. [University of York, Heslington, York (GB); Kaeppeler, F. [Institut fuer Kernphysik, Karlsruhe Institute of Technology, Campus Nord, Karlsruhe (DE); Koehler, P. [Oak Ridge National Laboratory (ORNL), Oak Ridge (US); Lederer, C. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE); University of Vienna, Faculty of Physics, Vienna (AT); Massimi, C.; Mingrone, F.; Vannini, G. [Universita di Bologna (IT); INFN, Sezione di Bologna, Dipartimento di Fisica, Bologna (IT); Mengoni, A.; Ventura, A. [Agenzia nazionale per le nuove tecnologie, l' energia e lo sviluppo economico sostenibile (ENEA), Bologna (IT); Milazzo, P.M. [Sezione di Trieste, INFN, Trieste (IT); Mirea, M. [Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Mondalaers, W.; Plompen, A.; Schillebeeckx, P. [Institute for Reference Materials and Measurements, European Commission JRC, Geel (BE); Pavlik, A.; Wallner, A. [University of Vienna, Faculty of Physics, Vienna (AT); Rauscher, T. [University of Basel, Department of Physics and Astronomy, Basel (CH); Roman, F. [European Organization for Nuclear Research (CERN), Geneva (CH); Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Rubbia, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Laboratori Nazionali del Gran Sasso dell' INFN, Assergi (AQ) (IT); Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE)

    2013-12-15

    The neutron flux of the n{sub T}OF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the n{sub T}OF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n{sub T}OF. An unexpected anomaly in the neutron-induced fission cross section of {sup 235}U is observed in the energy region between 10 and 30keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties. (orig.)

  18. Navigation Facility for High Accuracy Offline Trajectory and Attitude Estimation in Airborne Applications

    Directory of Open Access Journals (Sweden)

    A. Renga

    2013-01-01

    Full Text Available The paper focuses on a navigation facility, relying on commercial-off-the-shelf (COTS technology, developed to generate high-accuracy attitude and trajectory measurements in postprocessing. Target performance is cm-level positioning with tenth of degree attitude accuracy. The facility is based on the concept of GPS-aided inertial navigation but comprises carrier-phase differential GPS (CDGPS processing and attitude estimation based on multiantenna GPS configurations. Expected applications of the system include: (a performance assessment of integrated navigation systems, developed for general aviation aircraft and medium size unmanned aircraft systems (UAS; (b generation of reference measurements to evaluate the flight performance of airborne sensors (e.g., radar or laser; and (c generation of reference trajectory and attitude for improving imaging quality of airborne remote sensing data. The paper describes system architecture, selected algorithms for data processing and integration, and theoretical performance evaluation. Experimental results are also presented confirming the effectiveness of the implemented approach.

  19. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Directory of Open Access Journals (Sweden)

    Guy Jean-Pierre Schumann

    2016-01-01

    Full Text Available Digital elevation models (DEMs are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  20. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Science.gov (United States)

    Schumann, Guy; Moller, Delwyn; Mentgen, Felix

    2015-12-01

    Digital elevation models (DEMs) are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  1. Prognostic Accuracy of the SOFA Score, SIRS Criteria, and qSOFA Score for In-Hospital Mortality Among Adults With Suspected Infection Admitted to the Intensive Care Unit.

    Science.gov (United States)

    Raith, Eamon P; Udy, Andrew A; Bailey, Michael; McGloughlin, Steven; MacIsaac, Christopher; Bellomo, Rinaldo; Pilcher, David V

    2017-01-17

    The Sepsis-3 Criteria emphasized the value of a change of 2 or more points in the Sequential [Sepsis-related] Organ Failure Assessment (SOFA) score, introduced quick SOFA (qSOFA), and removed the systemic inflammatory response syndrome (SIRS) criteria from the sepsis definition. Externally validate and assess the discriminatory capacities of an increase in SOFA score by 2 or more points, 2 or more SIRS criteria, or a qSOFA score of 2 or more points for outcomes among patients who are critically ill with suspected infection. Retrospective cohort analysis of 184 875 patients with an infection-related primary admission diagnosis in 182 Australian and New Zealand intensive care units (ICUs) from 2000 through 2015. SOFA, qSOFA, and SIRS criteria applied to data collected within 24 hours of ICU admission. The primary outcome was in-hospital mortality. In-hospital mortality or ICU length of stay (LOS) of 3 days or more was a composite secondary outcome. Discrimination was assessed using the area under the receiver operating characteristic curve (AUROC). Adjusted analyses were performed using a model of baseline risk determined using variables independent of the scoring systems. Among 184 875 patients (mean age, 62.9 years [SD, 17.4]; women, 82 540 [44.6%]; most common diagnosis bacterial pneumonia, 32 634 [17.7%]), a total of 34 578 patients (18.7%) died in the hospital, and 102 976 patients (55.7%) died or experienced an ICU LOS of 3 days or more. SOFA score increased by 2 or more points in 90.1%; 86.7% manifested 2 or more SIRS criteria, and 54.4% had a qSOFA score of 2 or more points. SOFA demonstrated significantly greater discrimination for in-hospital mortality (crude AUROC, 0.753 [99% CI, 0.750-0.757]) than SIRS criteria (crude AUROC, 0.589 [99% CI, 0.585-0.593]) or qSOFA (crude AUROC, 0.607 [99% CI, 0.603-0.611]). Incremental improvements were 0.164 (99% CI, 0.159-0.169) for SOFA vs SIRS criteria and 0.146 (99% CI, 0.142-0.151) for SOFA vs qSOFA (P

  2. SNP-based non-invasive prenatal testing detects sex chromosome aneuploidies with high accuracy

    Science.gov (United States)

    Samango-Sprouse, Carole; Banjevic, Milena; Ryan, Allison; Sigurjonsson, Styrmir; Zimmermann, Bernhard; Hill, Matthew; Hall, Megan P.; Westemeyer, Margaret; Saucier, Jennifer; Demko, Zachary; Rabinowitz, Matthew

    2013-01-01

    Objective To develop a single nucleotide polymorphism- and informatics-based non-invasive prenatal test that detects sex chromosome aneuploidies early in pregnancy. Methods Fifteen aneuploid samples, including thirteen 45,X, two 47,XXY, and one 47,XYY, along with 185 euploid controls, were analyzed. Cell-free DNA was isolated from maternal plasma, amplified in a single multiplex PCR assay that targeted 19,488 polymorphic loci covering chromosomes 13, 18, 21, X, and Y, and sequenced. Sequencing results were analyzed using a Bayesian-based maximum likelihood statistical method to determine copy number of interrogated chromosomes, calculating sample-specific accuracies. Results Of the samples that passed a stringent quality control metric (93%), the algorithm correctly identified copy number at all five chromosomes in all 187 samples, for 934/935 correct calls as early as 9.4 weeks of gestation. We detected 45,X with 91.7% sensitivity (CI: 61.5-99.8%) and 100% specificity (CI: 97.9-100%), and 47,XXY and 47,XYY. The average calculated accuracy was 99.78%. Conclusion This method non-invasively detected 45,X, 47,XXY, and 47,XYY fetuses from cfDNA isolated from maternal plasma with high calculated accuracies, and thus offers a non-invasive method with the potential to function as a routine screen allowing for early prenatal detection of rarely diagnosed yet commonly occurring sex aneuploidies. PMID:23712453

  3. High-accuracy defect sizing for nozzle attachment welds using asymmetric TOFD

    Energy Technology Data Exchange (ETDEWEB)

    Bloodworth, T. [AEA Technology, Risley (United Kingdom)

    1999-09-01

    Inspection procedures for the detection, characterisation and high-accuracy sizing of defects in nozzle attachment welds in a Swedish BWR have been developed. These welds are set-on nozzle-to-pipe attachment welds between the main recirculation pipe and related piping systems. The nozzles and the main recirculation pipe are made of ferritic steel with austenitic stainless steel cladding on the inner surface. The overall wall thickness of the nozzle is 30 mm. The inspection uses an automated pulse-echo technique for the detection and length sizing of defects. Software for the display of complex geometry ultrasonic data is used to assist in data analysis. An unorthodox automated ultrasonic TOFD technique is used to measure the through-wall height of defects. This technique deploys probes on both the nozzle and main pipe surfaces. The TOFD data for this complex geometry are analysed using the CGTOFD software, to locate the origin of defect edge signals. The Qualification detection criterion for this inspection is the detection of defects 6 mm x 18 mm (height x length) or greater. The required length measurement accuracy is {+-}14 mm and the required through-wall height measurement accuracy is {+-}2.3 mm. This last requirement is very demanding. The inspection procedures for detection and sizing passed Procedure Qualification when measured against the above criteria on an `open` test specimen. Data collection and analysis personnel have subsequently passed Personnel Qualification using `blind` specimens. (Author)

  4. Uncertainty and target accuracy studies for the very high temperature reactor(VHTR) physics parameters.

    Energy Technology Data Exchange (ETDEWEB)

    Taiwo, T. A.; Palmiotti, G.; Aliberti, G.; Salvatores, M.; Kim, T.K.

    2005-09-16

    The potential impact of nuclear data uncertainties on a number of performance parameters (core and fuel cycle) of the prismatic block-type Very High Temperature Reactor (VHTR) has been evaluated and results are presented in this report. An uncertainty analysis has been performed, based on sensitivity theory, which underlines what cross-sections, what energy range and what isotopes are responsible for the most significant uncertainties. In order to give guidelines on priorities for new evaluations or validation experiments, required accuracies on specific nuclear data have been derived, accounting for target accuracies on major design parameters. Results of an extensive analysis indicate only a limited number of relevant parameters do not meet the target accuracies assumed in this work; this does not imply that the existing nuclear cross-section data cannot be used for the feasibility and pre-conceptual assessments of the VHTR. However, the results obtained depend on the uncertainty data used, and it is suggested to focus some future evaluation work on the production of consistent, as far as possible complete and user oriented covariance data.

  5. High accuracy measurements of magnetic field integrals for the european XFEL undulator systems

    Science.gov (United States)

    Wolff-Fabris, Frederik; Viehweger, Marc; Li, Yuhui; Pflüger, Joachim

    2016-10-01

    Two high accuracy moving wire (MW) measurement systems based on stretched wire technique were built for the European XFEL (XFEL.EU). They were dedicated to monitor, tune and improve the magnetic field integrals properties during the serial production of the undulator segments, phase shifters and air coil correctors for XFEL.EU. For the magnetic tuning of phase shifters and the calibration of the air coils correctors a short portable MW measurement bench was built to measure first field integrals in short devices with magnetic length of less than about 300 mm and with an ultimate accuracy much better than 1 G cm (0.001 T mm). A long MW measurement setup was dedicated to obtain the total first and second field integrals on the 5-meters long undulator segments with accuracy of about 4 G cm (0.004 T mm) and 2000 G cm2 (20 T mm2) for the 1st and 2nd field integrals, respectively. Using these data a method was developed to compute the proper corrections for the air coils correctors used at both extremities so that zero first and second field integrals for an undulator segment are obtained. It is demonstrated that charging air coils correctors with these corrections results in near zero effect to the electron trajectory in the undulator systems and consequently no negative impact on the self-amplified spontaneous emission (SASE) process should occur.

  6. Accuracy assessment of high frequency 3D ultrasound for digital impression-taking of prepared teeth

    Science.gov (United States)

    Heger, Stefan; Vollborn, Thorsten; Tinschert, Joachim; Wolfart, Stefan; Radermacher, Klaus

    2013-03-01

    Silicone based impression-taking of prepared teeth followed by plaster casting is well-established but potentially less reliable, error-prone and inefficient, particularly in combination with emerging techniques like computer aided design and manufacturing (CAD/CAM) of dental prosthesis. Intra-oral optical scanners for digital impression-taking have been introduced but until now some drawbacks still exist. Because optical waves can hardly penetrate liquids or soft-tissues, sub-gingival preparations still need to be uncovered invasively prior to scanning. High frequency ultrasound (HFUS) based micro-scanning has been recently investigated as an alternative to optical intra-oral scanning. Ultrasound is less sensitive against oral fluids and in principal able to penetrate gingiva without invasively exposing of sub-gingival preparations. Nevertheless, spatial resolution as well as digitization accuracy of an ultrasound based micro-scanning system remains a critical parameter because the ultrasound wavelength in water-like media such as gingiva is typically smaller than that of optical waves. In this contribution, the in-vitro accuracy of ultrasound based micro-scanning for tooth geometry reconstruction is being investigated and compared to its extra-oral optical counterpart. In order to increase the spatial resolution of the system, 2nd harmonic frequencies from a mechanically driven focused single element transducer were separated and corresponding 3D surface models were calculated for both fundamentals and 2nd harmonics. Measurements on phantoms, model teeth and human teeth were carried out for evaluation of spatial resolution and surface detection accuracy. Comparison of optical and ultrasound digital impression taking indicate that, in terms of accuracy, ultrasound based tooth digitization can be an alternative for optical impression-taking.

  7. Angoff Method of Setting Cut Scores for High-Stakes Testing: Foley Catheter Checkoff as an Exemplar.

    Science.gov (United States)

    Kardong-Edgren, Suzan; Mulcock, Pamela M

    2016-01-01

    The Angoff method is a commonly used and legally defensible method for setting passing or cut scores for high-stakes examinations. It also can be used for setting passing scores on clinical skill checklists. Two variations of the Angoff method were compared with a traditional and arbitrary 75% passing score, using a Foley catheter insertion checklist as an exemplar. Both Angoff methods produced slightly lower scores than our traditional scoring; because of "must pass" steps on our checklist, 12 of 13 students still failed the evaluation. The project uncovered multiple variations of checklists within different courses and variations in teaching practices for this skill.

  8. THE INFLUENCE OF SPECKLE ON HIGH RESOLUTION RANGE PROFILE RECOGNITION BASED ON THE MATCHING SCORE

    Institute of Scientific and Technical Information of China (English)

    Zhang Rui; Wei Xizhang; Li Xiang

    2012-01-01

    Template database is the key to radar automation target recognition based on High Resolution Range Profile (HRRP).From the traditional perspective,average HRRP is a valid template for it can represent each HRRP without scatterer Moving Through Range Cell (MTRC).However,template database based on this assumption is always challenged by measured data.One reason is that speckle happens in the frame without scatterer MTRC.Speckle makes HRRP fluctuate sharply and not match well with the average HRRP.We precisely introduce the formation mechanism of speckle.Then,we make an insight into the principle of matching score.Based on the conclusion,we study the properties of matching score between speckled HRRP and the average HRRP.The theoretical analysis and Monte Carlo experimental results demonstrate that speckle makes HRRP not to match well with the average HRRP according to the energy ratio of speckled scatterers.On the assumption of ideal scattering centre model,speckled HRRP has a matching score less than 85% with the average HRRP if speckled scatterers occupy more than 50% energy of the target.

  9. Voting for image scoring and assessment (VISA)--theory and application of a 2 + 1 reader algorithm to improve accuracy of imaging endpoints in clinical trials.

    Science.gov (United States)

    Gottlieb, Klaus; Hussain, Fez

    2015-02-19

    Independent central reading or off-site reading of imaging endpoints is increasingly used in clinical trials. Clinician-reported outcomes, such as endoscopic disease activity scores, have been shown to be subject to bias and random error. Central reading attempts to limit bias and improve accuracy of the assessment, two factors that are critical to trial success. Whether one central reader is sufficient and how to best integrate the input of more than one central reader into one output measure, is currently not known.In this concept paper we develop the theoretical foundations of a reading algorithm that can achieve both objectives without jeopardizing operational efficiency We examine the role of expert versus competent reader, frame scoring of imaging as a classification task, and propose a voting algorithm (VISA: Voting for Image Scoring and Assessment) as the most appropriate solution which could also be used to operationally define imaging gold standards. We propose two image readers plus an optional third reader in cases of disagreement (2 + 1) for ordinary scoring tasks. We argue that it is critical in trials with endoscopically determined endpoints to include the score determined by the site reader, at least in endoscopy clinical trials. Juries with more than 3 readers could define a reference standard that would allow a transition from measuring reader agreement to measuring reader accuracy. We support VISA by applying concepts from engineering (triple-modular redundancy) and voting theory (Condorcet's jury theorem) and illustrate our points with examples from inflammatory bowel disease trials, specifically, the endoscopy component of the Mayo Clinic Score of ulcerative colitis disease activity. Detailed flow-diagrams (pseudo-code) are provided that can inform program design.The VISA "2 + 1" reading algorithm, based on voting, can translate individual reader scores into a final score in a fashion that is both mathematically sound (by avoiding

  10. A High-Performance Operational Amplifier for High-Speed High-Accuracy Switch-Capacitor Cells

    Institute of Scientific and Technical Information of China (English)

    Qi Fan; Ning Ning; Qi Yu; Da Chen

    2007-01-01

    A highspeed highaccuracy fully differenttial operational amplifier (opamp) is realized based on noMillercapacitor feedforward (NMCF) compensation scheme. In order to achieve a good phase margin, the NMCF compensation scheme uses the positive phase shift of lefthalfplane (LHP) zero caused by the feedforward path to counteract the negative phase shift of the nondominant pole. Compared to traditional Miller compensation method, the opamp obtains high gain and wide band synchronously without the polesplitting effect while saves significant chip area due to the absence of the Miller capacitor. Simulated by the 0.35 μm CMOS RF technology, the result shows that the openloop gain of the opamp is 118 dB with the unity gainbandwidth (UGBW)of 1 GHz, and the phase margin is 61°while the settling time is 5.8 ns when achieving 0.01% accuracy. The opamp is especially suitable for the frontend sample/hold (S/H)cell and the multiplying D/A converter(MDAC) module of the highspeed highresolution pipelined A/D converters(ADCs).

  11. Ultra-high accuracy optical testing: creating diffraction-limitedshort-wavelength optical systems

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman,Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli,Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-08-03

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-{angstrom} and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date.

  12. High Accuracy, Two-Dimensional Read-Out in Multiwire Proportional Chambers

    Science.gov (United States)

    Charpak, G.; Sauli, F.

    1973-02-14

    In most applications of proportional chambers, especially in high-energy physics, separate chambers are used for measuring different coordinates. In general one coordinate is obtained by recording the pulses from the anode wires around which avalanches have grown. Several methods have been imagined for obtaining the position of an avalanche along a wire. In this article a method is proposed which leads to the same range of accuracies and may be preferred in some cases. The problem of accurate measurements for large-size chamber is also discussed.

  13. High-accuracy thickness measurement of a transparent plate with the heterodyne central fringe identification technique

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Wang-Tsung; Hsieh, Hung-Chih; Chang, Wei-Yao; Chen, Yen-Liang; Su, Der-Chin

    2011-07-20

    In a modified Twyman-Green interferometer, the optical path variation is measured with the heterodyne central fringe identification technique, as the light beam is focused by a displaced microscopic objective on the front/rear surface of the test transparent plate. The optical path length variation is then measured similarly after the test plate is removed. The geometrical thickness of the test plate can be calculated under the consideration of dispersion effect. This method has a wide measurable range and a high accuracy in the measurable range.

  14. A small and high accuracy gyro stabilization electro-optical platform

    Science.gov (United States)

    Qiu, Haitao; Han, Yonggen; Lv, Yanhong

    2008-10-01

    A high accuracy line-of-sight (LOS) Stabilization system based on digital control technology was designed. The current feedback closed-loop system was introduced which uses the CCD graphic and resolver to constitute the position closed-loop and uses the optic fiber gyro to constitute the rate closed-loop. In order to realize zero steady-state error of angular output in counteracting disturbance from carrier, a PII2 (proportional-integral-double integral) control scheme is proposed. The hardware configuration and software system is presented. Experimental results show that the system has perfect dynamic and static performance and the technical requirements were satisfied.

  15. High Accuracy Three-dimensional Simulation of Micro Injection Moulded Parts

    DEFF Research Database (Denmark)

    Tosello, Guido; Costa, F. S.; Hansen, Hans Nørgaard

    2011-01-01

    Micro injection moulding (μIM) is the key replication technology for high precision manufacturing of polymer micro products. Data analysis and simulations on micro-moulding experiments have been conducted during the present validation study. Detailed information about the μIM process was gathered...... and used to establish a reliable simulation methodology suitable for μIM parts. Various Simulation set-up parameters that have been considered in order to improve the simulation accuracy: injection speed profile, melt and mould temperatures, 3D mesh, material rheology, inertia effect and shrinkage...

  16. High-accuracy mass determination of unstable nuclei with a Penning trap mass spectrometer

    CERN Multimedia

    2002-01-01

    The mass of a nucleus is its most fundamental property. A systematic study of nuclear masses as a function of neutron and proton number allows the observation of collective and single-particle effects in nuclear structure. Accurate mass data are the most basic test of nuclear models and are essential for their improvement. This is especially important for the astrophysical study of nuclear synthesis. In order to achieve the required high accuracy, the mass of ions captured in a Penning trap is determined via their cyclotron frequency $ \

  17. An angle encoder for super-high resolution and super-high accuracy using SelfA

    Science.gov (United States)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-06-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 221 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science & Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 233, that is, corresponding to a 0.0015″ signal period after

  18. High-accuracy current sensing circuit with current compensation technique for buck-boost converter

    Science.gov (United States)

    Rao, Yuan; Deng, Wan-Ling; Huang, Jun-Kai

    2015-03-01

    A novel on-chip current sensing circuit with current compensation technique suitable for buck-boost converter is presented in this article. The proposed technique can sense the full-range inductor current with high accuracy and high speed. It is mainly based on matched current mirror and does not require a large proportion of aspect ratio between the powerFET and the senseFET, thus it reduces the complexity of circuit design and the layout mismatch issue without decreasing the power efficiency. The circuit is fabricated with TSMC 0.25 µm 2P5M mixed-signal process. Simulation results show that the buck-boost converter can be operated at 200 kHz to 4 MHz switching frequency with an input voltage from 2.8 to 4.7 V. The output voltage is 3.6 V, and the maximum accuracy for both high and low side sensing current reaches 99% within the load current ranging from 200 to 600 mA.

  19. Simple high-accuracy resolution program for convective modelling of discontinuities

    Science.gov (United States)

    Leonard, B. P.

    1988-01-01

    For steady multidimensional convection, the Quadratic Upstream Interpolation for Convective Kinematics (QUICK) scheme has several attractive properties. However, for highly convective simulation of step profiles, QUICK produces unphysical overshoots and a few oscillations, and this may cause serious problems in nonlinear flows. Fortunately, it is possible to modify the convective flux by writing the normalized convected control-volume face value as a function of the normalized adjacent upstream node value, developing criteria for monotonic resolution without sacrificing formal accuracy. This results in a nonlinear functional relationship between the normalized variables, whereas standard methods are all linear in this sense. The resulting Simple High Accuracy Resolution Program (SHARP) can be applied to steady multidimensional flows containing thin shear or mixing layers, shock waves, and other frontal phenomena. This represents a significant advance in modeling highly convective flows of engineering and geophysical importance. SHARP is based on an explicit, conservative, control-volume flux formation, equally applicable to one, two, or three dimensional elliptic, parabolic, hyperbolic, or mixed-flow regimes. Results are given for the bench-mark purely convective first-order results and the nonmonotonic predictions of second- and third-order upwinding.

  20. High-accuracy optimal finite-thrust trajectories for Moon escape

    Science.gov (United States)

    Shen, Hong-Xin; Casalino, Lorenzo

    2017-02-01

    The optimization problem of fuel-optimal trajectories from a low circular Moon orbit to a target hyperbolic excess velocity vector using finite-thrust propulsion is solved. The ability to obtain the most accurate satisfaction of necessary optimality conditions in a high-accuracy dynamic model is the main motivation of the current study. The solutions allow attaining anytime-return Earth-interface conditions from a low lunar orbit. Gravitational effects of the Sun, Earth, and Moon are included throughout the entire trajectory. Severe constraints on the fuel budget combined with high-accuracy demands on the endpoint conditions necessitate a high-fidelity solution to the trajectory optimization problem and JPL DE405 ephemeris model is used to determine the perturbing bodies' positions. The optimization problem is solved using an indirect method. The optimality of the solution is verified by an application of Pontryagin's maximum principle. More accurate and fuel-efficient trajectories are found for the same mission objectives and constraints published in other research, emphasizing the advantages of this technique. It is also shown that the thrust structure consists of three finite burns. In contrast to previous research, no singular arc is required in the optimal solutions, and all the controls appear bang-bang.

  1. Emergency positioning system accuracy with infrared LEDs in high-security facilities

    Science.gov (United States)

    Knoch, Sierra N.; Nelson, Charles; Walker, Owens

    2017-05-01

    Instantaneous personnel location presents a challenge in Department of Defense applications where high levels of security restrict real-time tracking of crew members. During emergency situations, command and control requires immediate accountability of all personnel. Current radio frequency (RF) based indoor positioning systems can be unsuitable due to RF leakage and electromagnetic interference with sensitively calibrated machinery on variable platforms like ships, submarines and high-security facilities. Infrared light provide a possible solution to this problem. This paper proposes and evaluates an indoor line-of-sight positioning system that is comprised of IR and high-sensitivity CMOS camera receivers. In this system the movement of the LEDs is captured by the camera, uploaded and analyzed; the highest point of power is located and plotted to create a blueprint of crewmember location. Results provided evaluate accuracy as a function of both wavelength and environmental conditions. Research will further evaluate the accuracy of the LED transmitter and CMOS camera receiver system. Transmissions in both the 780 and 850nm IR are analyzed.

  2. The Consistency between Human Raters and an Automated Essay Scoring System in Grading High School Students' English Writing

    Science.gov (United States)

    Tsai, Min-hsiu

    2012-01-01

    This study investigates the consistency between human raters and an automated essay scoring system in grading high school students' English compositions. A total of 923 essays from 23 classes of 12 senior high schools in Taiwan (Republic of China) were obtained and scored manually and electronically. The results show that the consistency between…

  3. A risk score to predict type 2 diabetes mellitus in an elderly Spanish Mediterranean population at high cardiovascular risk.

    Directory of Open Access Journals (Sweden)

    Marta Guasch-Ferré

    Full Text Available INTRODUCTION: To develop and test a diabetes risk score to predict incident diabetes in an elderly Spanish Mediterranean population at high cardiovascular risk. MATERIALS AND METHODS: A diabetes risk score was derived from a subset of 1381 nondiabetic individuals from three centres of the PREDIMED study (derivation sample. Multivariate Cox regression model ß-coefficients were used to weigh each risk factor. PREDIMED-personal Score included body-mass-index, smoking status, family history of type 2 diabetes, alcohol consumption and hypertension as categorical variables; PREDIMED-clinical Score included also high blood glucose. We tested the predictive capability of these scores in the DE-PLAN-CAT cohort (validation sample. The discrimination of Finnish Diabetes Risk Score (FINDRISC, German Diabetes Risk Score (GDRS and our scores was assessed with the area under curve (AUC. RESULTS: The PREDIMED-clinical Score varied from 0 to 14 points. In the subset of the PREDIMED study, 155 individuals developed diabetes during the 4.75-years follow-up. The PREDIMED-clinical score at a cutoff of ≥6 had sensitivity of 72.2%, and specificity of 72.5%, whereas AUC was 0.78. The AUC of the PREDIMED-clinical Score was 0.66 in the validation sample (sensitivity = 85.4%; specificity = 26.6%, and was significantly higher than the FINDRISC and the GDRS in both the derivation and validation samples. DISCUSSION: We identified classical risk factors for diabetes and developed the PREDIMED-clinical Score to determine those individuals at high risk of developing diabetes in elderly individuals at high cardiovascular risk. The predictive capability of the PREDIMED-clinical Score was significantly higher than the FINDRISC and GDRS, and also used fewer items in the questionnaire.

  4. A Risk Score to Predict Type 2 Diabetes Mellitus in an Elderly Spanish Mediterranean Population at High Cardiovascular Risk

    Science.gov (United States)

    Guasch-Ferré, Marta; Bulló, Mònica; Costa, Bernardo; Martínez-Gonzalez, Miguel Ángel; Ibarrola-Jurado, Núria; Estruch, Ramon; Barrio, Francisco; Salas-Salvadó, Jordi

    2012-01-01

    Introduction To develop and test a diabetes risk score to predict incident diabetes in an elderly Spanish Mediterranean population at high cardiovascular risk. Materials and Methods A diabetes risk score was derived from a subset of 1381 nondiabetic individuals from three centres of the PREDIMED study (derivation sample). Multivariate Cox regression model ß-coefficients were used to weigh each risk factor. PREDIMED-personal Score included body-mass-index, smoking status, family history of type 2 diabetes, alcohol consumption and hypertension as categorical variables; PREDIMED-clinical Score included also high blood glucose. We tested the predictive capability of these scores in the DE-PLAN-CAT cohort (validation sample). The discrimination of Finnish Diabetes Risk Score (FINDRISC), German Diabetes Risk Score (GDRS) and our scores was assessed with the area under curve (AUC). Results The PREDIMED-clinical Score varied from 0 to 14 points. In the subset of the PREDIMED study, 155 individuals developed diabetes during the 4.75-years follow-up. The PREDIMED-clinical score at a cutoff of ≥6 had sensitivity of 72.2%, and specificity of 72.5%, whereas AUC was 0.78. The AUC of the PREDIMED-clinical Score was 0.66 in the validation sample (sensitivity = 85.4%; specificity = 26.6%), and was significantly higher than the FINDRISC and the GDRS in both the derivation and validation samples. Discussion We identified classical risk factors for diabetes and developed the PREDIMED-clinical Score to determine those individuals at high risk of developing diabetes in elderly individuals at high cardiovascular risk. The predictive capability of the PREDIMED-clinical Score was significantly higher than the FINDRISC and GDRS, and also used fewer items in the questionnaire. PMID:22442692

  5. High accuracy genotyping directly from genomic DNA using a rolling circle amplification based assay

    Directory of Open Access Journals (Sweden)

    Du Yuefen

    2003-05-01

    Full Text Available Abstract Background Rolling circle amplification of ligated probes is a simple and sensitive means for genotyping directly from genomic DNA. SNPs and mutations are interrogated with open circle probes (OCP that can be circularized by DNA ligase when the probe matches the genotype. An amplified detection signal is generated by exponential rolling circle amplification (ERCA of the circularized probe. The low cost and scalability of ligation/ERCA genotyping makes it ideally suited for automated, high throughput methods. Results A retrospective study using human genomic DNA samples of known genotype was performed for four different clinically relevant mutations: Factor V Leiden, Factor II prothrombin, and two hemochromatosis mutations, C282Y and H63D. Greater than 99% accuracy was obtained genotyping genomic DNA samples from hundreds of different individuals. The combined process of ligation/ERCA was performed in a single tube and produced fluorescent signal directly from genomic DNA in less than an hour. In each assay, the probes for both normal and mutant alleles were combined in a single reaction. Multiple ERCA primers combined with a quenched-peptide nucleic acid (Q-PNA fluorescent detection system greatly accellerated the appearance of signal. Probes designed with hairpin structures reduced misamplification. Genotyping accuracy was identical from either purified genomic DNA or genomic DNA generated using whole genome amplification (WGA. Fluorescent signal output was measured in real time and as an end point. Conclusions Combining the optimal elements for ligation/ERCA genotyping has resulted in a highly accurate single tube assay for genotyping directly from genomic DNA samples. Accuracy exceeded 99 % for four probe sets targeting clinically relevant mutations. No genotypes were called incorrectly using either genomic DNA or whole genome amplified sample.

  6. Discovery and validation of urine markers of acute pediatric appendicitis using high accuracy mass spectrometry

    Science.gov (United States)

    Kentsis, Alex; Lin, Yin Yin; Kurek, Kyle; Calicchio, Monica; Wang, Yan Yan; Monigatti, Flavio; Campagne, Fabien; Lee, Richard; Horwitz, Bruce; Steen, Hanno; Bachur, Richard

    2015-01-01

    Study Objective Molecular definition of disease has been changing all aspects of medical practice, from diagnosis and screening to understanding and treatment. Acute appendicitis is among many human conditions that are complicated by the heterogeneity of clinical presentation and shortage of diagnostic markers. Here, we sought to profile the urine of patients with appendicitis with the goal of identifying new diagnostic markers. Methods Candidate markers were identified from the urine of children with histologically proven appendicitis by using high accuracy mass spectrometry proteome profiling. These systemic and local markers were used to assess the probability of appendicitis in a blinded, prospective study of children being evaluated for acute abdominal pain in our emergency department. Tests of performance of the markers were evaluated against the pathologic diagnosis and histologic grade of appendicitis. Results Test performance of 57 identified candidate markers was studied in 67 patients, with median age of 11 years, 37% of whom had appendicitis. Several exhibited favorable diagnostic performance, including calgranulin A (S100-A8), α-1-acid glycoprotein 1 (orosomucoid), and leucine-rich α-2-glycoprotein (LRG), with the ROC AUC and values of 0.84 (95 % CI 0.72-0.95), 0.84 (0.72-0.95), and 0.97 (0.93-1.0), respectively. LRG was enriched in diseased appendices and its abundance correlated with severity of appendicitis. Conclusions High accuracy mass spectrometry urine proteome profiling allowed identification of diagnostic markers of acute appendicitis. Usage of LRG and other identified biomarkers may improve the diagnostic accuracy of clinical evaluations of appendicitis. PMID:19556024

  7. SpaceNav - A high accuracy navigation system for space applications

    Science.gov (United States)

    Evers, H.-H.

    The technology of the SpaceNav-system is based on research performed by the Institute of Flight Guidance and Control at the Technical University of Braunschweig, Germany. In 1989 this institute gave the worlds first public demonstration of a fully automatic landing of an aircraft, using inertial and satellite informations exclusively. The SpaceNav device components are: Acceleration-/Gyro Sensor Package; Global Positioning System (GPS) Receiver/optional more than one; Time Reference Unit; CPU; Telemetry (optional); and Differential GPS (DGPS) Receiver (optional). The coupling of GPS receivers with inertial sensors provides an extremely accurate navigation data set in real time applications even in phases with high dynamic conditions. The update rate of this navigation information is up to 100 Hz with the same accuracy in 3D-position, velocity, acceleration, attitude and time. SpaceNav is an integrated navigation system, which operates according to the principle of combining the longterm stability and accuracy of GPS, and the high level of dynamic precision of conventional inertial navigation system (INS) strapdown systems. The system's design allows other aiding sensors e.g. GLONASS satellite navigation system, distance measuring equipment (DME), altimeter (radar and/or barometric), flux valve etc. to be connected, in order to increase the redundancy of the system. The advantage of such an upgraded system is the availability of more sensor information than necessary for a navigation solution. The resulting redundancy in range measurement allows real-time detection and identification of sensor signals that are incompatible with the other information. As a result you get Receiver Autonomous Integrity Monitoring (RAIM) as described in 'A Multi-Sensor Approach to Assuring GPS Integrity', presented by Alison Brown in the March/April 1990 issue of 'GPS World'. In this paper the author presents information about the principles of the Satellite Navigation System GPS, and

  8. High accuracy of family history of melanoma in Danish melanoma cases

    DEFF Research Database (Denmark)

    Wadt, Karin A W; Drzewiecki, Krzysztof T; Gerdes, Anne-Marie

    2015-01-01

    The incidence of melanoma in Denmark has immensely increased over the last 10 years making Denmark a high risk country for melanoma. In the last two decades multiple public campaigns have sought to increase the awareness of melanoma. Family history of melanoma is a known major risk factor...... but previous studies have shown that self-reported family history of melanoma is highly inaccurate. These studies are 15 years old and we wanted to examine if a higher awareness of melanoma has increased the accuracy of self-reported family history of melanoma. We examined the family history of 181 melanoma...... probands who reported 199 cases of melanoma in relatives, of which 135 cases where in first degree relatives. We confirmed the diagnosis of melanoma in 77% of all relatives, and in 83% of first degree relatives. In 181 probands we validated the negative family history of melanoma in 748 first degree...

  9. High Accuracy mass Measurement of the very Short-Lived Halo Nuclide $^{11}$Li

    CERN Multimedia

    Le scornet, G

    2002-01-01

    The archetypal halo nuclide $^{11}$Li has now attracted a wealth of experimental and theoretical attention. The most outstanding property of this nuclide, its extended radius that makes it as big as $^{48}$Ca, is highly dependent on the binding energy of the two neutrons forming the halo. New generation experiments using radioactive beams with elastic proton scattering, knock-out and transfer reactions, together with $\\textit{ab initio}$ calculations require the tightening of the constraint on the binding energy. Good metrology also requires confirmation of the sole existing precision result to guard against a possible systematic deviation (or mistake). We propose a high accuracy mass determintation of $^{11}$Li, a particularly challenging task due to its very short half-life of 8.6 ms, but one perfectly suiting the MISTRAL spectrometer, now commissioned at ISOLDE. We request 15 shifts of beam time.

  10. Arithmetic Accuracy in Children From High- and Low-Income Schools

    Directory of Open Access Journals (Sweden)

    Elida V. Laski

    2016-04-01

    Full Text Available This study investigated income group differences in kindergartners’ and first graders’ (N = 161 arithmetic by examining the link between accuracy and strategy use on simple and complex addition problems. Low-income children were substantially less accurate than high-income children, in terms of both percentage of correctly solved problems and the magnitude of errors, with low-income first graders being less accurate than high-income kindergartners. Higher-income children were more likely to use sophisticated mental strategies than their lower-income peers, who used predominantly inefficient counting or inappropriate strategies. Importantly, this difference in strategies mediated the relation between income group and addition. Examining underlying strategies has implications for understanding income group differences in arithmetic and potential means of remedying it via instruction.

  11. High Accuracy Liquid Propellant Slosh Predictions Using an Integrated CFD and Controls Analysis Interface

    Science.gov (United States)

    Marsell, Brandon; Griffin, David; Schallhorn, Dr. Paul; Roth, Jacob

    2012-01-01

    Coupling computational fluid dynamics (CFD) with a controls analysis tool elegantly allows for high accuracy predictions of the interaction between sloshing liquid propellants and th e control system of a launch vehicle. Instead of relying on mechanical analogs which are not valid during aU stages of flight, this method allows for a direct link between the vehicle dynamic environments calculated by the solver in the controls analysis tool to the fluid flow equations solved by the CFD code. This paper describes such a coupling methodology, presents the results of a series of test cases, and compares said results against equivalent results from extensively validated tools. The coupling methodology, described herein, has proven to be highly accurate in a variety of different cases.

  12. Integrated CFD and Controls Analysis Interface for High Accuracy Liquid Propellant Slosh Predictions

    Science.gov (United States)

    Marsell, Brandon; Griffin, David; Schallhorn, Paul; Roth, Jacob

    2012-01-01

    Coupling computational fluid dynamics (CFD) with a controls analysis tool elegantly allows for high accuracy predictions of the interaction between sloshing liquid propellants and the control system of a launch vehicle. Instead of relying on mechanical analogs which are n0t va lid during all stages of flight, this method allows for a direct link between the vehicle dynamic environments calculated by the solver in the controls analysis tool to the fluid now equations solved by the CFD code. This paper describes such a coupling methodology, presents the results of a series of test cases, and compares said results against equivalent results from extensively validated tools. The coupling methodology, described herein, has proven to be highly accurate in a variety of different cases.

  13. Using Mobile Laser Scanning Data for Features Extraction of High Accuracy Driving Maps

    Science.gov (United States)

    Yang, Bisheng; Liu, Yuan; Liang, Fuxun; Dong, Zhen

    2016-06-01

    High Accuracy Driving Maps (HADMs) are the core component of Intelligent Drive Assistant Systems (IDAS), which can effectively reduce the traffic accidents due to human error and provide more comfortable driving experiences. Vehicle-based mobile laser scanning (MLS) systems provide an efficient solution to rapidly capture three-dimensional (3D) point clouds of road environments with high flexibility and precision. This paper proposes a novel method to extract road features (e.g., road surfaces, road boundaries, road markings, buildings, guardrails, street lamps, traffic signs, roadside-trees, power lines, vehicles and so on) for HADMs in highway environment. Quantitative evaluations show that the proposed algorithm attains an average precision and recall in terms of 90.6% and 91.2% in extracting road features. Results demonstrate the efficiencies and feasibilities of the proposed method for extraction of road features for HADMs.

  14. Initial development of high-accuracy CFRP panel for DATE5 antenna

    Science.gov (United States)

    Qian, Yuan; Lou, Zheng; Hao, Xufeng; Zhu, Jing; Cheng, Jingquan; Wang, Hairen; Zuo, Yingxi; Yang, Ji

    2016-07-01

    DATE5 antenna, which is a 5m telescope for terahertz exploration, will be sited at Dome A, Antarctica. It is necessary to keep high surface accuracy of the primary reflector panels so that high observing efficiency can be achieved. In antenna field, carbon fiber reinforced composite (CFRP) sandwich panels are widely used as these panels are light in weight, high in strength, low in thermal expansion, and cheap in mass fabrication. In DATE5 project, CFRP panels are important panel candidates. In the design study phase, a CFRP prototype panel of 1-meter size is initially developed for the verification purpose. This paper introduces the material arrangement in the sandwich panel, measured performance of this testing sandwich structure samples, and together with the panel forming process. For anti-icing in the South Pole region, a special CFRP heating film is embedded in the front skin of sandwich panel. The properties of some types of basic building materials are tested. Base on the results, the deformation of prototype panel with different sandwich structures and skin layers are simulated and a best structural concept is selected. The panel mold used is a high accuracy one with a surface rms error of 1.4 μm. Prototype panels are replicated from the mold. Room temperature curing resin is used to reduce the thermal deformation in the resin transfer process. In the curing, vacuum negative pressure technology is also used to increase the volume content of carbon fiber. After the measurement of the three coordinate measure machine (CMM), a prototype CFRP panel of 5.1 μm rms surface error is developed initially.

  15. Borderline Ovarian Tumors and Diagnostic Dilemma of Intraoperative Diagnosis: Could Preoperative He4 Assay and ROMA Score Assessment Increase the Frozen Section Accuracy? A Multicenter Case-Control Study

    Directory of Open Access Journals (Sweden)

    Salvatore Gizzo

    2014-01-01

    Full Text Available The aim of our study was to assess the value of a preoperative He4-serum-assay and ROMA-score assessment in improving the accuracy of frozen section histology in the diagnosis of borderline ovarian tumors (BOT. 113 women presenting with a unilateral ovarian mass diagnosed as serous/mucinous BOT at frozen-section-histology (FS and/or confirmed on final pathology were recruited. Pathologists were informed of the results of preoperative clinical/instrumental assessment of all patients. For Group_A patients, additional information regarding He4, CA125, and ROMA score was available (in Group_B only CA125 was known. The comparison between Group A and Group B in terms of FS accuracy, demonstrated a consensual diagnosis in 62.8% versus 58.6% (P: n.s., underdiagnosis in 25.6% versus 41.4% (P<0.05, and overdiagnosis in 11.6% versus 0% (P<0.01. Low FS diagnostic accuracy was associated with menopausal status (OR: 2.13, laparoscopic approach (OR: 2.18, mucinous histotype (OR: 2.23, low grading (OR: 1.30, and FIGO stage I (OR: 2.53. Ultrasound detection of papillae (OR: 0.29, septa (OR: 0.39, atypical vascularization (OR: 0.34, serum He4 assay (OR: 0.39, and ROMA score assessment (OR: 0.44 decreased the probability of underdiagnosis. A combined preoperative assessment through serum markers and ultrasonographic features may potentially reduce the risk of underdiagnosis of BOTs on FS while likely increasing the concomitant incidence of false-positive events.

  16. Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery

    Directory of Open Access Journals (Sweden)

    Loutfi-Krauss Britta

    2017-09-01

    Full Text Available For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany, which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA with 4.0mm resolution and to the Nonius (QUART, Germany, a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm. The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for

  17. PACMAN Project: A New Solution for the High-accuracy Alignment of Accelerator Components

    CERN Document Server

    Mainaud Durand, Helene; Buzio, Marco; Caiazza, Domenico; Catalán Lasheras, Nuria; Cherif, Ahmed; Doytchinov, Iordan; Fuchs, Jean-Frederic; Gaddi, Andrea; Galindo Munoz, Natalia; Gayde, Jean-Christophe; Kamugasa, Solomon; Modena, Michele; Novotny, Peter; Russenschuck, Stephan; Sanz, Claude; Severino, Giordana; Tshilumba, David; Vlachakis, Vasileios; Wendt, Manfred; Zorzetti, Silvia

    2016-01-01

    The beam alignment requirements for the next generation of lepton colliders have become increasingly challenging. As an example, the alignment requirements for the three major collider components of the CLIC linear collider are as follows. Before the first beam circulates, the Beam Position Monitors (BPM), Accelerating Structures (AS)and quadrupoles will have to be aligned up to 10 μm w.r.t. a straight line over 200 m long segments, along the 20 km of linacs. PACMAN is a study on Particle Accelerator Components' Metrology and Alignment to the Nanometre scale. It is an Innovative Doctoral Program, funded by the EU and hosted by CERN, providing high quality training to 10 Early Stage Researchers working towards a PhD thesis. The technical aim of the project is to improve the alignment accuracy of the CLIC components by developing new methods and tools addressing several steps of alignment simultaneously, to gain time and accuracy. The tools and methods developed will be validated on a test bench. This paper pr...

  18. An output amplitude configurable wideband automatic gain control with high gain step accuracy

    Institute of Scientific and Technical Information of China (English)

    何晓丰; 莫太山; 马成炎; 叶甜春

    2012-01-01

    An output amplitude configurable wideband automatic gain control (AGC) with high gain step accuracy for the GNSS receiver is presented.The amplitude of an AGC is configurable in order to cooperate with baseband chips to achieve interference suppression and be compatible with different full range ADCs.And what's more,the gain-boosting technology is introduced and the circuit is improved to increase the step accuracy.A zero,which is composed by the source feedback resistance and the source capacity,is introduced to compensate for the pole.The AGC is fabricated in a 0.18 μm CMOS process.The AGC shows a 62 dB gain control range by 1 dB each step with a gain error of less than 0.2 dB.The AGC provides 3 dB bandwidth larger than 80 MHz and the overall power consumption is less than 1.8 mA,and the die area is 800 × 300μm2.

  19. Accuracy of the high-throughput amplicon sequencing to identify species within the genus Aspergillus.

    Science.gov (United States)

    Lee, Seungeun; Yamamoto, Naomichi

    2015-12-01

    This study characterized the accuracy of high-throughput amplicon sequencing to identify species within the genus Aspergillus. To this end, we sequenced the internal transcribed spacer 1 (ITS1), β-tubulin (BenA), and calmodulin (CaM) gene encoding sequences as DNA markers from eight reference Aspergillus strains with known identities using 300-bp sequencing on the Illumina MiSeq platform, and compared them with the BLASTn outputs. The identifications with the sequences longer than 250 bp were accurate at the section rank, with some ambiguities observed at the species rank due to mostly cross detection of sibling species. Additionally, in silico analysis was performed to predict the identification accuracy for all species in the genus Aspergillus, where 107, 210, and 187 species were predicted to be identifiable down to the species rank based on ITS1, BenA, and CaM, respectively. Finally, air filter samples were analysed to quantify the relative abundances of Aspergillus species in outdoor air. The results were reproducible across biological duplicates both at the species and section ranks, but not strongly correlated between ITS1 and BenA, suggesting the Aspergillus detection can be taxonomically biased depending on the selection of the DNA markers and/or primers.

  20. Real-Time and High-Accuracy Arctangent Computation Using CORDIC and Fast Magnitude Estimation

    Directory of Open Access Journals (Sweden)

    Luca Pilato

    2017-03-01

    Full Text Available This paper presents an improved VLSI (Very Large Scale of Integration architecture for real-time and high-accuracy computation of trigonometric functions with fixed-point arithmetic, particularly arctangent using CORDIC (Coordinate Rotation Digital Computer and fast magnitude estimation. The standard CORDIC implementation suffers of a loss of accuracy when the magnitude of the input vector becomes small. Using a fast magnitude estimator before running the standard algorithm, a pre-processing magnification is implemented, shifting the input coordinates by a proper factor. The entire architecture does not use a multiplier, it uses only shift and add primitives as the original CORDIC, and it does not change the data path precision of the CORDIC core. A bit-true case study is presented showing a reduction of the maximum phase error from 414 LSB (angle error of 0.6355 rad to 4 LSB (angle error of 0.0061 rad, with small overheads of complexity and speed. Implementation of the new architecture in 0.18 µm CMOS technology allows for real-time and low-power processing of CORDIC and arctangent, which are key functions in many embedded DSP systems. The proposed macrocell has been verified by integration in a system-on-chip, called SENSASIP (Sensor Application Specific Instruction-set Processor, for position sensor signal processing in automotive measurement applications.

  1. High Accuracy Mass Measurement of the Dripline Nuclides $^{12,14}$Be

    CERN Multimedia

    2002-01-01

    State-of-the art, three-body nuclear models that describe halo nuclides require the binding energy of the halo neutron(s) as a critical input parameter. In the case of $^{14}$Be, the uncertainty of this quantity is currently far too large (130 keV), inhibiting efforts at detailed theoretical description. A high accuracy, direct mass deterlnination of $^{14}$Be (as well as $^{12}$Be to obtain the two-neutron separation energy) is therefore required. The measurement can be performed with the MISTRAL spectrometer, which is presently the only possible solution due to required accuracy (10 keV) and short half-life (4.5 ms). Having achieved a 5 keV uncertainty for the mass of $^{11}$Li (8.6 ms), MISTRAL has proved the feasibility of such measurements. Since the current ISOLDE production rate of $^{14}$Be is only about 10/s, the installation of a beam cooler is underway in order to improve MISTRAL transmission. The projected improvement of an order of magnitude (in each transverse direction) will make this measureme...

  2. Combined Scintigraphy and Tumor Marker Analysis Predicts Unfavorable Histopathology of Neuroblastic Tumors with High Accuracy.

    Directory of Open Access Journals (Sweden)

    Wolfgang Peter Fendler

    Full Text Available Our aim was to improve the prediction of unfavorable histopathology (UH in neuroblastic tumors through combined imaging and biochemical parameters.123I-MIBG SPECT and MRI was performed before surgical resection or biopsy in 47 consecutive pediatric patients with neuroblastic tumor. Semi-quantitative tumor-to-liver count-rate ratio (TLCRR, MRI tumor size and margins, urine catecholamine and NSE blood levels of neuron specific enolase (NSE were recorded. Accuracy of single and combined variables for prediction of UH was tested by ROC analysis with Bonferroni correction.34 of 47 patients had UH based on the International Neuroblastoma Pathology Classification (INPC. TLCRR and serum NSE both predicted UH with moderate accuracy. Optimal cut-off for TLCRR was 2.0, resulting in 68% sensitivity and 100% specificity (AUC-ROC 0.86, p < 0.001. Optimal cut-off for NSE was 25.8 ng/ml, resulting in 74% sensitivity and 85% specificity (AUC-ROC 0.81, p = 0.001. Combination of TLCRR/NSE criteria reduced false negative findings from 11/9 to only five, with improved sensitivity and specificity of 85% (AUC-ROC 0.85, p < 0.001.Strong 123I-MIBG uptake and high serum level of NSE were each predictive of UH. Combined analysis of both parameters improved the prediction of UH in patients with neuroblastic tumor. MRI parameters and urine catecholamine levels did not predict UH.

  3. High-accuracy same-beam VLBI observations using Shanghai and Urumqi telescopes

    Institute of Scientific and Technical Information of China (English)

    KIKUCHI; Fuyuhiko; KAMATA; Shun’ichi; MATSUMOTO; Koji; HANADA; Hideo

    2009-01-01

    The same-beam VLBI observations of Rstar and Vstar,which were two small satellites of Japanese lunar mission,SELENE,were successfully performed by using Shanghai and Urumqi 25-m telescopes. When the separation angle between Rstar and Vstar was less than 0.1 deg,the differential phase delay of the X-band signals between Rstar and Vstar on Shanghai-Urumqi baseline was obtained with a very small error of 0.15 mm rms,which was reduced by 1-2 order compared with the former VLBI results. When the separation angle was less than 0.56 deg,the differential phase delay of the S-band signals was also obtained with a very small error of several mm rms. The orbit determination for Rstar and Vstar was performed,and the accuracy was improved to a level of several meters by using VLBI and Doppler data. The high-accuracy same-beam differential VLBI technique is very useful in orbit determination for a spacecraft,and will be used in orbit determination for Mars missions of China Yinghuo-1 and Russia Phobos-grunt.

  4. High-accuracy same-beam VLBI observations using Shanghai and Urumqi telescopes

    Institute of Scientific and Technical Information of China (English)

    LIU QingHui; PING JingSong; FAN QingYuan; XIA Bo; AN Tao; QIAN ZhiHan; YANG WenJun; ZHANG Hua; WANG Zhen; WANG Na; SHI Xian; KIKUCHI Fuyuhiko; HUANG Qian; KAMATA Shun'ichi; MATSUMOTO Koji; HANADA Hideo; HONG XiaoYu; YU AiLi

    2009-01-01

    The same-beam VLBI observations of Rstar and Vstar, which were two small satellites of Japanese lunar mission, SELENE, were successfully performed by using Shanghai and Urumqi 25-m telescopes.When the separation angle between Rstar and Vstar was less than 0.1 deg, the differential phase delay of the X-band signals between Rstar and Vstar on Shanghai-Urumqi baseline was obtained with a very small error of 0.15 mm rms, which was reduced by 1-2 order compared with the former VLBI results.When the separation angle was less than 0.56 deg, the differential phase delay of the S-band signals was also obtained with a very small error of several mm rms. The orbit determination for Rstar and Vstar was performed, and the accuracy was improved to a level of several meters by using VLBI and Doppler data. The high-accuracy same-beam differential VLBI technique is very useful in orbit determination for a spacecraft, and will be used in orbit determination for Mars missions of China Yinghuo-1 and Russia Phobos-grunt.

  5. Reducing Systematic Centroid Errors Induced by Fiber Optic Faceplates in Intensified High-Accuracy Star Trackers

    Science.gov (United States)

    Xiong, Kun; Jiang, Jie

    2015-01-01

    Compared with traditional star trackers, intensified high-accuracy star trackers equipped with an image intensifier exhibit overwhelmingly superior dynamic performance. However, the multiple-fiber-optic faceplate structure in the image intensifier complicates the optoelectronic detecting system of star trackers and may cause considerable systematic centroid errors and poor attitude accuracy. All the sources of systematic centroid errors related to fiber optic faceplates (FOFPs) throughout the detection process of the optoelectronic system were analyzed. Based on the general expression of the systematic centroid error deduced in the frequency domain and the FOFP modulation transfer function, an accurate expression that described the systematic centroid error of FOFPs was obtained. Furthermore, reduction of the systematic error between the optical lens and the input FOFP of the intensifier, the one among multiple FOFPs and the one between the output FOFP of the intensifier and the imaging chip of the detecting system were discussed. Two important parametric constraints were acquired from the analysis. The correctness of the analysis on the optoelectronic detecting system was demonstrated through simulation and experiment. PMID:26016920

  6. Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice Computed Tomography coronary angiography; Influenza di attenuazione vascolare, frequenza cardiaca e calcium score sull'accuratezza diagnostica in angiografia coronarica non invasiva mediante Tomografia Computerizzata multistrato

    Energy Technology Data Exchange (ETDEWEB)

    Cademartiri, Filippo; Mollet, Nico R.; Kriestin, Gabriel P. [Erasmus Medical Center, Rotterdam (Netherlands). Dipartimento di radiologia; Runza, Giuseppe; Bartolotta, Tommaso Vincenzo; Galia, Massimo; Midiri, Massimo [Palermo Univ., Palermo (Italy). DIBIMEL, Sezione di scienze radiologiche; Belgrano, Manuel; Pozzi Mucelli, Roberto [Trieste Univ., Trieste (Italy). Ospedale di Cattinara, Istituto di radiologia

    2005-07-15

    Purpose. To assess the effect of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). Materials and methods. One hundred patients (88 males; 59{+-}11 years) with suspected coronary artery disease who had undergone conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA, with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 2.8 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol 320 mgI/nl at 4 ml/s and the scan delay was defined with a bolus tracking technique. In all patients vascular enhancement was measured in the aortic root, and the left and the right coronary arteries. The average enhancement was used to divide the population in two groups of 50 patients each, one with lower enhancement (Low), and one with higher enhancement (High). In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis ({>=}50% lumen reduction) was evaluated in vessels {>=}2mm in diameter using quantitative CA as the reference standard. The differences in diagnostic accuracy were compared with a Chi-square test and a p<0.05 was considered significant. Results. Of the total 1116 segments ({>=}2 mm lumen diameter), 173 presented significant stenosis. The sensitivity and specificity for the assessment of significant stenosis were 89.4% and 93.3% vs 94.3% and 97.4% in the presence of increasing intravascular enhancement, 92.8% and 96.7% vs 91.1% and 93.9% in the presence of increasing heart rate, and 89.7% and 97.6% vs 93.3% and 92.8% in the presence of increasing calcium score. Conclusions. Increasing intravascular enhancement significantly improves diagnostic accuracy in MSCT-CA. A higher heart rate lowers the specificity in the detection of significant

  7. Swing arm profilometer: high accuracy testing for large reaction-bonded silicon carbide optics with a capacitive probe

    Science.gov (United States)

    Xiong, Ling; Luo, Xiao; Hu, Hai-xiang; Zhang, Zhi-yu; Zhang, Feng; Zheng, Li-gong; Zhang, Xue-jun

    2017-08-01

    A feasible way to improve the manufacturing efficiency of large reaction-bonded silicon carbide optics is to increase the processing accuracy in the ground stage before polishing, which requires high accuracy metrology. A swing arm profilometer (SAP) has been used to measure large optics during the ground stage. A method has been developed for improving the measurement accuracy of SAP using a capacitive probe and implementing calibrations. The experimental result compared with the interferometer test shows the accuracy of 0.068 μm in root-mean-square (RMS) and maps in 37 low-order Zernike terms show accuracy of 0.048 μm RMS, which shows a powerful capability to provide a major input in high-precision grinding.

  8. [Diagnostic accuracy of the immersion high-frequency B-scan ultrasonography in chemical injured eyes].

    Science.gov (United States)

    Yang, Qinghua; Chen, Bing; Wang, Liqiang; Li, Zhaohui; Huang, Yifei

    2014-08-01

    To investigate the diagnostic accuracy of the immersion high-frequency B-scan ultrasonography, a noninvasive preoperative diagnosis method, in observing the anterior segment in chemical injured eyes. It was a retrospective study. Sixty-three ocular chemical injury patients (63 eyes), who accepted the keratoplasty or the artificial cornea transplant in PLA General Hospital from May 2011 to May 2013, were included in this study. All the injured eyes were examined by ultrasound bio-microscopy (UBM) and immersion high-frequency B-scan ultrasonography, respectively. The images were analyzed and the results were compared with the intraoperative findings. The observation of lens was the main parameter. All the 63 patients were examined with the UBM and the immersion high-frequency B-scan ultrasonography before the surgery. The findings of the cornea, anterior chamber angle, iris from UBM were consistent with those from the immersion high-frequency B-scan ultrasonography. As for the lens observation, in 32 eyes in which the lens were not detected by UBM, the lens were not detected in only 16 eyes, while 3 eyes with normal lens and 13 eyes with lens pacifications (1 eye with pyknotic lens) by immersion high-frequency B-scan ultrasonography. In 17 eyes in which the lens were found normal by UBM, there were only 14 eyes with normal lens and the rest 3 eyes' lens were found intumescent by immersion high-frequency B-scan ultrasonography. In 6 eyes in which lens were detected with suspicious by UBM, 2 eyes' lens were pyknotic and 4 eyes' lens were intumescent or clouded by immersion high-frequency B-scan ultrasonography. The findings of immersion high-frequency B-scan ultrasonography were highly consistent with the intraoperative findings. The lens could be observed accurately by immersion high-frequency B-scan ultrasonography in chemical injured eyes.

  9. High-accuracy infra-red thermography method using reflective marker arrays

    Science.gov (United States)

    Kirollos, Benjamin; Povey, Thomas

    2017-09-01

    In this paper, we describe a new method for high-accuracy infra-red (IR) thermography measurements in situations with significant spatial variation in reflected radiation from the surroundings, or significant spatial variation in surface emissivity due to viewing angle non-uniformity across the field of view. The method employs a reflective marker array (RMA) on the target surface—typically, high emissivity circular dots—and an integrated image analysis algorithm designed to require minimal human input. The new technique has two particular advantages which make it suited to high-accuracy measurements in demanding environments: (i) it allows the reflected radiation component to be calculated directly, in situ, and as a function of position, overcoming a key problem in measurement environments with non-uniform and unsteady stray radiation from the surroundings; (ii) using image analysis of the marker array (via apparent aspect ratio of the circular reflective markers), the local viewing angle of the target surface can be estimated, allowing corrections for angular variation of local emissivity to be performed without prior knowledge of the geometry. A third advantage of the technique is that allows for simple focus-stacking algorithms due to increased image entropy. The reflective marker array method is demonstrated for an isothermal, hemispherical object exposed to an external IR source arranged to give a significant non-uniform reflected radiation term. This is an example of a challenging environment, both because of the significant non-uniform reflected radiation term, and also the significant variation in target emissivity due to surface angle variation. We demonstrate that the new RMA IR technique leads to significantly lower error in evaluated surface temperature than conventional IR techniques. The method is applicable to any complex radiative environment.

  10. Novel Dielectric Coagulometer Identifies Hypercoagulability in Patients with a High CHADS2 Score without Atrial Fibrillation.

    Directory of Open Access Journals (Sweden)

    Yuki Hasegawa

    Full Text Available Recent reports showed that the CHADS2 score predicted the risk of strokes in patients without atrial fibrillation (AF. Although the hypercoagulability may contribute to the thrombogenesis, it has not been fully investigated due to a lack of a sensitive evaluation modality. Recently a novel dielectric blood coagulometry (DBCM was invented for evaluating the coagulability by measuring the temporal change in whole blood dielectric permittivity.We evaluated the utility of the DBCM for identifying the coagulability.For fundamental experiments, 133 citrated blood samples were drawn from subjects with or without heparin administration. A DBCM analysis was performed to find the adequate coagulation index, and to delineate its measurement range by adding recombinant human tissue factor (TF or heparin. Then the coagulability was assessed by DBCM and conventional coagulation assays in 84 subjects without AF, who were divided into 3 groups by their CHADS2 score. Another 17 patients who received warfarin were also assessed by DBCM to evaluate the effect of anticoagulants.We calculated the derivative of the dielectric permittivity change after recalcification, and extracted the end of acceleration time (EAT as a novel index. The EAT showed a dose-dependent shortening with the addition of serial dilutions of TF (×10-2 to ×10-4, and a dose-dependent prolongation with the addition of heparin (0.05 to 0.15 U/ml. The EAT was significantly shorter in the higher CHADS2 score group (19.8 ± 4.8, 18.6 ± 3.1, and 16.3 ± 2.7 min in the CHADS2 = 0, 1, and ≥2 groups, respectively, p = 0.0065 by ANOVA. Patients receiving warfarin had a significantly more prolonged EAT than those without warfarin (18.6±4.2 vs. 25.8±7.3 min, p <0.001. DBCM detected the whole blood coagulability with a high sensitivity. Subjects with higher CHADS2 scores exhibited hypercoagulability without AF.

  11. Design and calibration of a high-sensitivity and high-accuracy polarimeter based on liquid crystal variable retarders

    Science.gov (United States)

    Guo, Jing; Ren, De-Qing; Liu, Cheng-Chao; Zhu, Yong-Tian; Dou, Jiang-Pei; Zhang, Xi; Beck, Christian

    2017-01-01

    Polarimetry plays an important role in the measurement of solar magnetic fields. We developed a high-sensitivity and high-accuracy polarimeter (HHP) based on nematic liquid crystal variable retarders (LCVRs), which has a compact setup and no mechanical moving parts. The system design and calibration methods are discussed in detail. The azimuth error of the transmission axis of the polarizer as well as the fast axes of the two LCVRs and the quarter-wave plate were determined using dedicated procedures. Linearly and circularly polarized light were employed to evaluate the performance of the HHP. The experimental results indicate that a polarimetric sensitivity of better than \\[5.7 × {10 - 3}\\] can be achieved by using a single short-exposure image, while an accuracy on the order of 10‑5 can be reached by using a large number of short-exposure images. This makes the HHP a high-performance system that can be used with a ground-based solar telescope for high-precision solar magnetic field investigations.

  12. Modelo predictivo de "score" de calcio alto en pacientes con factores de riesgo cardiovascular Predictive model of high calcium score in patients with cardiovascular risk factors

    Directory of Open Access Journals (Sweden)

    Gloria Franco

    2007-12-01

    prueba del score de calcio coronario a un paciente con factores de riesgo cardiovascular. Se puede observar que muchos de los factores de riesgo que se correlacionan con un valor elevado de "score" de calcio coronario pueden ser modificables: cesar el hábito de fumar o realizar ejercicio.Introduction: it has been found through multiple studies that coronary calcium score is a good predictor of coronary disease in asymptomatic individuals with one or more cardiovascular risk factors; therefore it would be ideal to perform this test in order to stratify its risk, but due to economic factors this is not possible in most cases. The model presented allows predicting the probability that a patient may have a high coronary calcium score by means of his cardiovascular risk factors. The originality of the model is that it also comprises "protector" factors that diminish such probability. Methods: study of cases and controls in asymptomatic patients with cardiovascular risk factors to whom a PCC had been performed. The cases are patients with coronary calcium score greater than percentile 75 for his age and gender; the control case relationship is 2:1. Results: ages ranged between 35 and 75 years; 14.4% were female; 44.4% had family history of CHD; 34.4% were hypertensive; 38.9% had high total cholesterol; 24.4% had HDL cholesterol under 40 mg/dl; 33.3% had LDL cholesterol greater than 160 mg/dl; 25.6% were cigarette smokers; 23.3% were sedentary; 13.3% were periodical alcohol consumers; 15.6% were obese (BMI > 30; 18.9% exercised periodically and 34.4% received statins. Cardiovascular risk factors correlated with high coronary calcium score are recorded in table 1. In the logistic regression model, factors having a p table 2 are obtained. Expression for the model would be: The values of ci values are 1, if the factor is present and 0 if it is not. Conclusions: this model does not pretend to replace stratification through Framinghan model; on the contrary, it is a complement that

  13. High accuracy Primary Reference gas Mixtures for high-impact greenhouse gases

    Science.gov (United States)

    Nieuwenkamp, Gerard; Zalewska, Ewelina; Pearce-Hill, Ruth; Brewer, Paul; Resner, Kate; Mace, Tatiana; Tarhan, Tanil; Zellweger, Christophe; Mohn, Joachim

    2017-04-01

    Climate change, due to increased man-made emissions of greenhouse gases, poses one of the greatest risks to society worldwide. High-impact greenhouse gases (CO2, CH4 and N2O) and indirect drivers for global warming (e.g. CO) are measured by the global monitoring stations for greenhouse gases, operated and organized by the World Meteorological Organization (WMO). Reference gases for the calibration of analyzers have to meet very challenging low level of measurement uncertainty to comply with the Data Quality Objectives (DQOs) set by the WMO. Within the framework of the European Metrology Research Programme (EMRP), a project to improve the metrology for high-impact greenhouse gases was granted (HIGHGAS, June 2014-May 2017). As a result of the HIGHGAS project, primary reference gas mixtures in cylinders for ambient levels of CO2, CH4, N2O and CO in air have been prepared with unprecedented low uncertainties, typically 3-10 times lower than usually previously achieved by the NMIs. To accomplish these low uncertainties in the reference standards, a number of preparation and analysis steps have been studied and improved. The purity analysis of the parent gases had to be performed with lower detection limits than previously achievable. E.g., to achieve an uncertainty of 2•10-9 mol/mol (absolute) on the amount fraction for N2O, the detection limit for the N2O analysis in the parent gases has to be in the sub nmol/mol domain. Results of an OPO-CRDS analyzer set-up in the 5µm wavelength domain, with a 200•10-12 mol/mol detection limit for N2O, will be presented. The adsorption effects of greenhouse gas components at cylinder surfaces are critical, and have been studied for different cylinder passivation techniques. Results of a two-year stability study will be presented. The fit-for-purpose of the reference materials was studied for possible variation on isotopic composition between the reference material and the sample. Measurement results for a suit of CO2 in air

  14. Very Low Power, Low Voltage, High Accuracy, and High Performance Current Mirror

    Institute of Scientific and Technical Information of China (English)

    Hassan Faraji Baghtash; Khalil Monfaredi; Ahmad Ayatollahi

    2011-01-01

    A novel low power and low voltage current mirror with a very low current copy error is presented and the principle of its operation is discussed.In this circuit,the gain boosting regulated cascode scheme is used to improve the output resistance,while using inverter as an amplifier.The simulation results with HSPICE in TSMC 0.18 μm CMOS technology are given,which verify the high performance of the proposed structure.Simulation results show an input resistance of 0.014 Ω and an output resistance of 3 GΩ.The current copy error is favorable as low as 0.002% together with an input (the minimum input voltage of vin,min~ 0.24 V) and an output (the minimum output voltage of vout,min~ 0.16 V) compliances while working with the 1 V power supply and the 50 μA input current.The current copy error is near zero at the input current of 27 μA.It consumes only 76 μW and introduces a very low output offset current of 50 pA.

  15. ADFE METHOD WITH HIGH ACCURACY FOR NONLINEAR PARABOLIC INTEGRO-DIFFERENTIAL SYSTEM WITH NONLINEAR BOUNDARY CONDITIONS

    Institute of Scientific and Technical Information of China (English)

    崔霞

    2002-01-01

    Alternating direction finite element (ADFE) scheme for d-dimensional nonlinear system of parabolic integro-differential equations is studied. By using a local approximation based on patches of finite elements to treat the capacity term qi(u), decomposition of the coefficient matrix is realized; by using alternating direction, the multi-dimensional problem is reduced to a family of single space variable problems, calculation work is simplified; by using finite element method, high accuracy for space variant is kept; by using inductive hypothesis reasoning, the difficulty coming from the nonlinearity of the coefficients and boundary conditions is treated; by introducing Ritz-Volterra projection, the difficulty coming from the memory term is solved. Finally, by using various techniques for priori estimate for differential equations, the unique resolvability and convergence properties for both FE and ADFE schemes are rigorously demonstrated, and optimal H1 and L2norm space estimates and O((△t)2) estimate for time variant are obtained.

  16. SLSTR: a high accuracy dual scan temperature radiometer for sea and land surface monitoring from space

    Science.gov (United States)

    Coppo, P.; Ricciarelli, B.; Brandani, F.; Delderfield, J.; Ferlet, M.; Mutlow, C.; Munro, G.; Nightingale, T.; Smith, D.; Bianchi, S.; Nicol, P.; Kirschstein, S.; Hennig, T.; Engel, W.; Frerick, J.; Nieke, J.

    2010-10-01

    SLSTR is a high accuracy infrared radiometer which will be embarked in the Earth low-orbit Sentinel 3 operational GMES mission. SLSTR is an improved version of the previous AATSR and ATSR-1/2 instruments which have flown respectively on Envisat and ERS-1/2 ESA missions. SLSTR will provide data continuity with respect to these previous missions but with a substantial improvement due to its higher swaths (750 km in dual view and 1400 km in single view) which should permit global coverage of SST and LST measurements (at 1 km of spatial resolution in IR channels) with daily revisit time, useful for climatological and meteorological applications. Two more SWIR channels and a higher spatial resolution in the VIS/SWIR channels (0.5 km) are also implemented for a better clouds/aerosols screening. Two further additional channels for global scale fire monitoring are present at the same time as the other nominal channels.

  17. Study on Calibration System for Electronic Transformers Based on High-Accuracy PCI Card

    Directory of Open Access Journals (Sweden)

    Mingzhu Zhang

    2013-03-01

    Full Text Available With preliminary applying of Electronic Transformer (ET based on IEC 61850 standards in power grid, the calibrations of tested transformers have attracted extensive research attention. This study proposes a novel Calibration System of ET (CSET based on high-accuracy card. Data acquisition of ET and Standard Trans-former (ST is gotten by optic Ethernet and PCI-4462 data acquisition card, respectively. Meanwhile, the synchronized sampling between ET and ST is completed on the optic/electronic pulse signal of PCI synchronization card. The signals processing and human interface are realized by Labview software. The system proposed in the study is feasible for calibrating Electronic Voltage/Current Transformers (EVT/ECT of different voltage classes. System tests show that the precision of the system can get to 0.2°.

  18. Study on Calibration System for Electronic Transformers Based on High-Accuracy PCI Card

    Directory of Open Access Journals (Sweden)

    Mingzhu Zhang

    2013-05-01

    Full Text Available With preliminary applying of Electronic Transformer (ET based on IEC 61850 standards in power grid, the calibration of tested transformers has attracted extensive research attention. This study proposes a novel Calibration System of ET (CSET based on high-accuracy card. Data acquisition of ET and standard trans-former (ST is gotten by optic Ethernet and PCI-4462 data acquisition card, respectively. Meanwhile, the synchronized sampling between ET and ST is completed on the optic/electronic pulse signal of PCI synchronization card. The signals processing and human interface are realized by Lab view software. The system proposed in the study is feasible for calibrating Electronic Voltage/Current Transformers (EVT/ECT of different voltage classes. System tests show that the precision of the system can get to 0.2°.

  19. High-Accuracy Programmable Timing Generator with Wide-Range Tuning Capability

    Directory of Open Access Journals (Sweden)

    Ting-Li Chu

    2013-01-01

    Full Text Available In this paper, a high-accuracy programmable timing generator with wide-range tuning capability is proposed. With the aid of dual delay-locked loop (DLL, both of the coarse- and fine-tuning mechanisms are operated in precise closed-loop scheme to lessen the effects of the ambient variations. The timing generator can provide sub-gate resolution and instantaneous switching capability. The circuit is implemented and simulated in TSMC 0.18 μm 1P6M technology. The test chip area occupies 1.9 mm2. The reference clock cycle can be divided into 128 bins by interpolation to obtain 14 ps resolution with the clock rate at 550 MHz. The INL and DNL are within −0.21~+0.78 and −0.27~+0.43 LSB, respectively.

  20. Well-posedness of the difference schemes of the high order of accuracy for elliptic equations

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available It is well known the differential equation − u ″ ( t +Au( t =f( t ( −∞high order of accuracy two-step difference schemes generated by an exact difference scheme or by Taylor's decomposition on three points for the approximate solutions of this differential equation. The well-posedness of these difference schemes in the difference analogy of the smooth functions is obtained. The exact almost coercive inequality for solutions in C( τ,E of these difference schemes is established.

  1. High-accuracy measurement of the magnetic moment anomaly of the electron bound in hydrogenlike carbon.

    Science.gov (United States)

    Häffner, H; Beier, T; Hermanspahn, N; Kluge, H J; Quint, W; Stahl, S; Verdú, J; Werth, G

    2000-12-18

    We present a new experimental value for the magnetic moment of the electron bound in hydrogenlike carbon (12C5+): g(exp) = 2.001 041 596 (5). This is the most precise determination of an atomic g(J) factor so far. The experiment was carried out on a single 12C5+ ion stored in a Penning trap. The high accuracy was made possible by spatially separating the induction of spin flips and the analysis of the spin direction. The current theoretical value amounts to g(th) = 2.001 041 591 (7). Together experiment and theory test the bound-state QED contributions to the g(J) factor of a bound electron to a precision of 1%.

  2. Computer-aided diagnosis of breast MRI with high accuracy optical flow estimation

    Science.gov (United States)

    Meyer-Baese, Anke; Barbu, Adrian; Lobbes, Marc; Hoffmann, Sebastian; Burgeth, Bernhard; Kleefeld, Andreas; Meyer-Bäse, Uwe

    2015-05-01

    Non-mass enhancing lesions represent a challenge for the radiological reading. They are not well-defined in both morphology (geometric shape) and kinetics (temporal enhancement) and pose a problem to lesion detection and classification. To enhance the discriminative properties of an automated radiological workflow, the correct preprocessing steps need to be taken. In an usual computer-aided diagnosis (CAD) system, motion compensation plays an important role. To this end, we employ a new high accuracy optical flow based motion compensation algorithm with robustification variants. An automated computer-aided diagnosis system evaluates the atypical behavior of these lesions, and additionally considers the impact of non-rigid motion compensation on a correct diagnosis.

  3. High Accuracy Speed-fed Grating Angular Acceleration Measurement System Based on FPGA

    Directory of Open Access Journals (Sweden)

    Hao Zhao

    2012-09-01

    Full Text Available Shaft angular acceleration is one of the most important parameter of rotary machines, the error of angular acceleration increased when the shaft speed up. For this problem, a new high accuracy angular acceleration measurement system is presented, the principle of measurement is self-regulating the period of speed sampling signal according to the proportion of the shaft speed up. This measurement system combined FPGA and SCM, the speed of shaft is received by the timer of SCM responding the interrupts of FPGA, and then set the parameter of frequency divider in FPGA, so as to make the period of speed sampling consistent with the proportion of the speed up. This measurement system could overcome the error when system speed up according to the experiment.

  4. High Accuracy Reference Network (HARN), Published in 2000, 1:600 (1in=50ft) scale, Brown County, WI.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This High Accuracy Reference Network (HARN) dataset, published at 1:600 (1in=50ft) scale, was produced all or in part from Field Survey/GPS information as of 2000....

  5. High-accuracy approximation of high-rank derivatives: isotropic finite differences based on lattice-Boltzmann stencils.

    Science.gov (United States)

    Mattila, Keijo Kalervo; Hegele Júnior, Luiz Adolfo; Philippi, Paulo Cesar

    2014-01-01

    We propose isotropic finite differences for high-accuracy approximation of high-rank derivatives. These finite differences are based on direct application of lattice-Boltzmann stencils. The presented finite-difference expressions are valid in any dimension, particularly in two and three dimensions, and any lattice-Boltzmann stencil isotropic enough can be utilized. A theoretical basis for the proposed utilization of lattice-Boltzmann stencils in the approximation of high-rank derivatives is established. In particular, the isotropy and accuracy properties of the proposed approximations are derived directly from this basis. Furthermore, in this formal development, we extend the theory of Hermite polynomial tensors in the case of discrete spaces and present expressions for the discrete inner products between monomials and Hermite polynomial tensors. In addition, we prove an equivalency between two approaches for constructing lattice-Boltzmann stencils. For the numerical verification of the presented finite differences, we introduce 5th-, 6th-, and 8th-order two-dimensional lattice-Boltzmann stencils.

  6. Motif-based success scores in coauthorship networks are highly sensitive to author name disambiguation

    Science.gov (United States)

    Klosik, David F.; Bornholdt, Stefan; Hütt, Marc-Thorsten

    2014-09-01

    Following the work of Krumov et al. [Eur. Phys. J. B 84, 535 (2011), 10.1140/epjb/e2011-10746-5] we revisit the question whether the usage of large citation datasets allows for the quantitative assessment of social (by means of coauthorship of publications) influence on the progression of science. Applying a more comprehensive and well-curated dataset containing the publications in the journals of the American Physical Society during the whole 20th century we find that the measure chosen in the original study, a score based on small induced subgraphs, has to be used with caution, since the obtained results are highly sensitive to the exact implementation of the author disambiguation task.

  7. TECHNOLOGICAL PROVISION OF ACCURACY AND QUALITY PARAMETERS OF INTRICATE PROFILE PARTS AT HIGH-SPEED MULTI-COORDINATE MACHINING

    Directory of Open Access Journals (Sweden)

    V. K. Sheleg

    2009-01-01

    Full Text Available The paper considers requirements to CAM-systems for provision of high-speed multi-coordinate milling, principles of generation and recommendations on trajectory programming for high-speed machining, influence of vibration and balancing of the technological system on parameters of  the machining accuracy, characteristics of a cutting tool, types of tool coatings that is rather actual for improvement of accuracy and quality of intricate profile parts.

  8. Integrative fitting of absorption line profiles with high accuracy, robustness, and speed

    Science.gov (United States)

    Skrotzki, Julian; Habig, Jan Christoph; Ebert, Volker

    2014-08-01

    The principle of the integrative evaluation of absorption line profiles relies on the numeric integration of absorption line signals to retrieve absorber concentrations, e.g., of trace gases. Thus, it is a fast and robust technique. However, previous implementations of the integrative evaluation principle showed shortcomings in terms of accuracy and the lack of a fit quality indicator. This has motivated the development of an advanced integrative (AI) fitting algorithm. The AI fitting algorithm retains the advantages of previous integrative implementations—robustness and speed—and is able to achieve high accuracy by introduction of a novel iterative fitting process. A comparison of the AI fitting algorithm with the widely used Levenberg-Marquardt (LM) fitting algorithm indicates that the AI algorithm has advantages in terms of robustness due to its independence from appropriately chosen start values for the initialization of the fitting process. In addition, the AI fitting algorithm shows speed advantages typically resulting in a factor of three to four shorter computational times on a standard personal computer. The LM algorithm on the other hand retains advantages in terms of a much higher flexibility, as the AI fitting algorithm is restricted to the evaluation of single absorption lines with precomputed line width. Comparing both fitting algorithms for the specific application of in situ laser hygrometry at 1,370 nm using direct tunable diode laser absorption spectroscopy (TDLAS) suggests that the accuracy of the AI algorithm is equivalent to that of the LM algorithm. For example, a signal-to-noise ratio of 80 and better typically yields a deviation of TDLAS hygrometry at the aerosol and cloud chamber aerosol interactions and dynamics in the atmosphere (AIDA)—a unique large-scale facility to study atmospheric processes. The robustness of the AI fitting algorithm has been validated for typical AIDA conditions encompassing strong transmission fluctuations

  9. Improved photomask accuracy with a high-productivity DUV laser pattern generator

    Science.gov (United States)

    Öström, Thomas; Måhlén, Jonas; Karawajczyk, Andrzej; Rosling, Mats; Carlqvist, Per; Askebjer, Per; Karlin, Tord; Sallander, Jesper; Österberg, Anders

    2006-10-01

    A strategy for sub-100 nm technology nodes is to maximize the use of high-speed deep-UV laser pattern generators, reserving e-beam tools for the most critical photomask layers. With a 248 nm excimer laser and 0.82 NA projection optics, the Sigma7500 increases the application space of laser pattern generators. A programmable spatial light modulator (SLM) is imaged with partially coherent optics to compose the photomask pattern. Image profiles are enhanced with phase shifting in the pattern generator, and features below 200 nm are reliably printed. The Sigma7500 extends the SLM-based architecture with improvements to CD uniformity and placement accuracy, resulting from an error budget-based methodology. Among these improvements is a stiffer focus stage design with digital servos, resulting in improved focus stability. Tighter climate controls and improved dose control reduce drift during mask patterning. As a result, global composite CD uniformity below 5 nm (3σ) has been demonstrated, with placement accuracy below 10 nm (3σ) across the mask. Self-calibration methods are used to optimize and monitor system performance, reducing the need to print test plates. The SLM calibration camera views programmed test patterns, making it possible to evaluate image metrics such as CD uniformity and line edge roughness. The camera is also used to characterize image placement over the optical field. A feature called ProcessEqualizer TM has been developed to correct long-range CD errors arising from process effects on production photomasks. Mask data is sized in real time to compensate for pattern-dependent errors related to local pattern density, as well as for systematic pattern-independent errors such as radial CD signatures. Corrections are made in the pixel domain in the advanced adjustments processor, which also performs global biasing, stamp distortion compensation, and corner enhancement. In the Sigma7500, the mask pattern is imaged with full edge addressability in each

  10. Convolutional neural networks for an automatic classification of prostate tissue slides with high-grade Gleason score

    Science.gov (United States)

    Jiménez del Toro, Oscar; Atzori, Manfredo; Otálora, Sebastian; Andersson, Mats; Eurén, Kristian; Hedlund, Martin; Rönnquist, Peter; Müller, Henning

    2017-03-01

    The Gleason grading system was developed for assessing prostate histopathology slides. It is correlated to the outcome and incidence of relapse in prostate cancer. Although this grading is part of a standard protocol performed by pathologists, visual inspection of whole slide images (WSIs) has an inherent subjectivity when evaluated by different pathologists. Computer aided pathology has been proposed to generate an objective and reproducible assessment that can help pathologists in their evaluation of new tissue samples. Deep convolutional neural networks are a promising approach for the automatic classification of histopathology images and can hierarchically learn subtle visual features from the data. However, a large number of manual annotations from pathologists are commonly required to obtain sufficient statistical generalization when training new models that can evaluate the daily generated large amounts of pathology data. A fully automatic approach that detects prostatectomy WSIs with high-grade Gleason score is proposed. We evaluate the performance of various deep learning architectures training them with patches extracted from automatically generated regions-of-interest rather than from manually segmented ones. Relevant parameters for training the deep learning model such as size and number of patches as well as the inclusion or not of data augmentation are compared between the tested deep learning architectures. 235 prostate tissue WSIs with their pathology report from the publicly available TCGA data set were used. An accuracy of 78% was obtained in a balanced set of 46 unseen test images with different Gleason grades in a 2-class decision: high vs. low Gleason grade. Grades 7-8, which represent the boundary decision of the proposed task, were particularly well classified. The method is scalable to larger data sets with straightforward re-training of the model to include data from multiple sources, scanners and acquisition techniques. Automatically

  11. Diagnostic accuracy of a five-point Likert scoring system for magnetic resonance imaging (MRI) evaluated according to results of MRI/ultrasonography image-fusion targeted biopsy of the prostate.

    Science.gov (United States)

    Shin, Toshitaka; Smyth, Thomas B; Ukimura, Osamu; Ahmadi, Nariman; de Castro Abreu, Andre Luis; Ohe, Chisato; Oishi, Masakatsu; Mimata, Hiromitsu; Gill, Inderbir S

    2017-07-27

    To evaluate the accuracy of a magnetic resonance imaging (MRI)-based Likert scoring system in the detection of clinically significant prostate cancer (CSPC), using MRI/ultrasonography (US) image-fusion targeted biopsy (FTB) as a reference standard. We retrospectively reviewed 1218 MRI-detected lesions in 629 patients who underwent subsequent MRI/US FTB between October 2012 and August 2015. 3-Tesla MRI was independently reported by one of eight radiologists with varying levels of experience and scored on a five-point Likert scale. All lesions with Likert scores 1-5 were prospectively defined as targets for MRI/US FTB. CSPC was defined as Gleason score ≥7. The median patient age was 64 years, PSA level 6.97 ng/mL and estimated prostate volume 52.2 mL. Of 1218 lesions, 48% (n = 581) were rated as Likert 1-2, 35% (n = 428) were Likert 3 and 17% (n = 209) were Likert 4-5. For Likert scores 1-5, the overall cancer detection rates were 12%, 13%, 22%, 50% and 59%, respectively, and the CSPC detection rates were 4%, 4%, 12%, 33% and 48%, respectively. Grading using the five-point scale showed strong positive correlation with overall cancer detection rate (r = 0.949, P = 0.05) and CSPC detection rate (r = 0.944, P = 0.05). By comparison, in Likert 4-5 lesions, significant differences were noted in overall cancer detection rate (63% vs 35%; P = 0.001) and CSPC detection rate (47% vs 29%; P = 0.027) for the more experienced vs the less experienced radiologists. The detection rates of overall cancer and CSPC strongly correlated with the five-point grading of the Likert scale. Among radiologists with different levels of experience, there were significant differences in these cancer detection rates. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  12. A new device for liver cancer biomarker detection with high accuracy

    Directory of Open Access Journals (Sweden)

    Shuaipeng Wang

    2015-06-01

    Full Text Available A novel cantilever array-based bio-sensor was batch-fabricated with IC compatible MEMS technology for precise liver cancer bio-marker detection. A micro-cavity was designed in the free end of the cantilever for local antibody-immobilization, thus adsorption of the cancer biomarker is localized in the micro-cavity, and the adsorption-induced k variation can be dramatically reduced with comparison to that caused by adsorption of the whole lever. The cantilever is pizeoelectrically driven into vibration which is pizeoresistively sensed by Wheatstone bridge. These structural features offer several advantages: high sensitivity, high throughput, high mass detection accuracy, and small volume. In addition, an analytical model has been established to eliminate the effect of adsorption-induced lever stiffness change and has been applied to precise mass detection of cancer biomarker AFP, the detected AFP antigen mass (7.6 pg/ml is quite close to the calculated one (5.5 pg/ml, two orders of magnitude better than the value by the fully antibody-immobilized cantilever sensor. These approaches will promote real application of the cantilever sensors in early diagnosis of cancer.

  13. High Accuracy Decoding of Dynamical Motion from a Large Retinal Population.

    Directory of Open Access Journals (Sweden)

    Olivier Marre

    2015-07-01

    Full Text Available Motion tracking is a challenge the visual system has to solve by reading out the retinal population. It is still unclear how the information from different neurons can be combined together to estimate the position of an object. Here we recorded a large population of ganglion cells in a dense patch of salamander and guinea pig retinas while displaying a bar moving diffusively. We show that the bar's position can be reconstructed from retinal activity with a precision in the hyperacuity regime using a linear decoder acting on 100+ cells. We then took advantage of this unprecedented precision to explore the spatial structure of the retina's population code. The classical view would have suggested that the firing rates of the cells form a moving hill of activity tracking the bar's position. Instead, we found that most ganglion cells in the salamander fired sparsely and idiosyncratically, so that their neural image did not track the bar. Furthermore, ganglion cell activity spanned an area much larger than predicted by their receptive fields, with cells coding for motion far in their surround. As a result, population redundancy was high, and we could find multiple, disjoint subsets of neurons that encoded the trajectory with high precision. This organization allows for diverse collections of ganglion cells to represent high-accuracy motion information in a form easily read out by downstream neural circuits.

  14. Model Accuracy Comparison for High Resolution Insar Coherence Statistics Over Urban Areas

    Science.gov (United States)

    Zhang, Yue; Fu, Kun; Sun, Xian; Xu, Guangluan; Wang, Hongqi

    2016-06-01

    The interferometric coherence map derived from the cross-correlation of two complex registered synthetic aperture radar (SAR) images is the reflection of imaged targets. In many applications, it can act as an independent information source, or give additional information complementary to the intensity image. Specially, the statistical properties of the coherence are of great importance in land cover classification, segmentation and change detection. However, compared to the amount of work on the statistical characters of SAR intensity, there are quite fewer researches on interferometric SAR (InSAR) coherence statistics. And to our knowledge, all of the existing work that focuses on InSAR coherence statistics, models the coherence with Gaussian distribution with no discrimination on data resolutions or scene types. But the properties of coherence may be different for different data resolutions and scene types. In this paper, we investigate on the coherence statistics for high resolution data over urban areas, by making a comparison of the accuracy of several typical statistical models. Four typical land classes including buildings, trees, shadow and roads are selected as the representatives of urban areas. Firstly, several regions are selected from the coherence map manually and labelled with their corresponding classes respectively. Then we try to model the statistics of the pixel coherence for each type of region, with different models including Gaussian, Rayleigh, Weibull, Beta and Nakagami. Finally, we evaluate the model accuracy for each type of region. The experiments on TanDEM-X data show that the Beta model has a better performance than other distributions.

  15. High Lung Allocation Score Is Associated With Increased Morbidity and Mortality Following Transplantation

    Science.gov (United States)

    Russo, Mark J.; Iribarne, Alexander; Hong, Kimberly N.; Davies, Ryan R.; Xydas, Steve; Takayama, Hiroo; Ibrahimiye, Ali; Gelijns, Annetine C.; Bacchetta, Matthew D.; D’Ovidio, Frank; Arcasoy, Selim

    2010-01-01

    Background: The lung allocation score (LAS) was initiated in May 2005 to allocate lungs based on medical urgency and posttransplant survival. The purpose of this study was to determine if there is an association between an elevated LAS at the time of transplantation and increased postoperative morbidity and mortality. Methods: The United Network for Organ Sharing provided de-identified patient-level data. Analysis included lung transplant recipients aged ≥ 12 years who received transplants between April 5, 2006, and December 31, 2007 (n = 3,836). Recipients were stratified into three groups: LAS < 50 (n = 3,161, 83.87%), LAS 50 to 75 (n = 411, 10.9%), and LAS ≥ 75 (n = 197, 5.23%), referred to as low LAS (LLAS), intermediate LAS (ILAS), and high LAS (HLAS), respectively. The primary outcome was posttransplant graft survival at 1 year. Secondary outcomes included length of stay and in-hospital complications. Results: HLAS recipients had significantly worse actuarial survival at 90 days and 1 year compared with LLAS recipients. When transplant recipients were stratified by disease etiology, a trend of decreased survival with elevated LAS was observed across all major causes of lung transplant. HLAS recipients were more likely to require dialysis or to have infections compared with LLAS recipients (P < .001). In addition, length of stay was higher in the HLAS group when compared with the LLAS group (P < .001). Conclusions: HLAS is associated with decreased survival and increased complications during the transplant hospitalization. Whereas the LAS has improved organ allocation through decreased waiting list deaths and waiting list times, lower survival and higher morbidity among HLAS recipients suggests that continued review of LAS scoring is needed to ensure optimal long-term transplant survival. PMID:19820072

  16. Prioritizing spatial accuracy in high-resolution fMRI data using multivariate feature weight mapping

    Directory of Open Access Journals (Sweden)

    Johannes eStelzer

    2014-04-01

    Full Text Available Although ultra-high-field fMRI at field strengths of 7T or above provides substantial gains in BOLD contrast-to-noise ratio, when very high-resolution fMRI is required such gains are inevitably reduced. The improvement in sensitivity provided by multivariate analysis techniques, as compared with univariate methods, then becomes especially welcome. Information mapping approaches are commonly used, such as the searchlight technique, which take into account the spatially distributed patterns of activation in order to predict stimulus conditions. However, the popular searchlight decoding technique, in particular, has been found to be prone to spatial inaccuracies. For instance, the spatial extent of informative areas is generally exaggerated, and their spatial configuration is distorted. We propose the combination of a nonparametric and permutation-based statistical framework with linear classifiers. We term this new combined method Feature Weight Mapping (FWM. The main goal of the proposed method is to map the specific contribution of each voxel to the classification decision while including a correction for the multiple comparisons problem. Next, we compare this new method to the searchlight approach using a simulation and ultra-high-field 7T experimental data. We found that the searchlight method led to spatial inaccuracies that are especially noticeable in high-resolution fMRI data. In contrast, FWM was more spatially precise, revealing both informative anatomical structures as well as the direction by which voxels contribute to the classification. By maximizing the spatial accuracy of ultra-high-field fMRI results, global multivariate methods provide a substantial improvement for characterizing structure-function relationships.

  17. High accuracy jog CD control on OPC pattern by advanced laser writer Sigma7500

    Science.gov (United States)

    Chin, Tomas; Wu, Wen-Bin; Shih, Chiang-Lin

    2008-10-01

    With the progress of mask writer technology, 50 KV electron beam writers always perform with better pattern fidelity and critical dimension (CD) control than traditional laser raster-scan writers because laser spot size is confined by the laser longer wavelength relative to electron beam. As far as Optical Proximity Correction (OPC) pattern fidelity is concerned, critical masks with OPC process have to choose Variable-Shape-Beam (VSB) electron beam writer presently. However, the over-aggressive OPC fragmentation induces data volume abrupt explosion, longer writing time, higher mask cost and even mask quality degradation 1. Micronic Sigma7500 laser writer introduces a novel imaging system combining partial coherent light and DUV spatial light modulation (SLM) to generate a high-quality pattern image 2. The benefit of raster-scan laser writer is high throughput with consistent writing time regardless of pattern geometry, complexity and data size. However, pattern CD accuracy still needs improvement. This study is to evaluate jog CD control capability of Sigma7500 on OPC typical line-and-space test patterns with different orientations of 0°, 90°, 45° and 135°. In addition, mask CD uniformity and OPC jog height linearity will also be demonstrated.

  18. High-Accuracy Ring Laser Gyroscopes: Earth Rotation Rate and Relativistic Effects

    Science.gov (United States)

    Beverini, N.; Di Virgilio, A.; Belfi, J.; Ortolan, A.; Schreiber, K. U.; Gebauer, A.; Klügel, T.

    2016-06-01

    The Gross Ring G is a square ring laser gyroscope, built as a monolithic Zerodur structure with 4 m length on all sides. It has demonstrated that a large ring laser provides a sensitivity high enough to measure the rotational rate of the Earth with a high precision of ΔΩE GINGER project is intending to take this level of sensitivity further and to improve the accuracy and the long-term stability. A monolithic structure similar to the G ring laser is not available for GINGER. Therefore the preliminary goal is the demonstration of the feasibility of a larger gyroscope structure, where the mechanical stability is obtained through an active control of the geometry. A prototype moderate size gyroscope (GP-2) has been set up in Pisa in order to test this active control of the ring geometry, while a second structure (GINGERino) has been installed inside the Gran Sasso underground laboratory in order to investigate the properties of a deep underground laboratory in view of an installation of a future GINGER apparatus. The preliminary data on these two latter instruments are presented.

  19. High accuracy and transferability of a neural network potential through charge equilibration for calcium fluoride

    Science.gov (United States)

    Faraji, Somayeh; Ghasemi, S. Alireza; Rostami, Samare; Rasoulkhani, Robabe; Schaefer, Bastian; Goedecker, Stefan; Amsler, Maximilian

    2017-03-01

    We investigate the accuracy and transferability of a recently developed high-dimensional neural network (NN) method for calcium fluoride, fitted to a database of ab initio density functional theory (DFT) calculations based on the Perdew-Burke-Ernzerhof (PBE) exchange correlation functional. We call the method charge equilibration via neural network technique (CENT). Although the fitting database contains only clusters (i.e., nonperiodic structures), the NN scheme accurately describes a variety of bulk properties. In contrast to other available empirical methods the CENT potential has a much simpler functional form, nevertheless it correctly reproduces the PBE energetics of various crystalline phases both at ambient and high pressure. Surface energies and structures as well as dynamical properties derived from phonon calculations are also in good agreement with PBE results. Overall, the difference between the values obtained by the CENT potential and the PBE reference values is less than or equal to the difference between the values of local density approximation (LDA) and Born-Mayer-Huggins (BMH) with those calculated by the PBE exchange correlation functional.

  20. Spline-based high-accuracy piecewise-polynomial phase-to-sinusoid amplitude converters.

    Science.gov (United States)

    Petrinović, Davor; Brezović, Marko

    2011-04-01

    We propose a method for direct digital frequency synthesis (DDS) using a cubic spline piecewise-polynomial model for a phase-to-sinusoid amplitude converter (PSAC). This method offers maximum smoothness of the output signal. Closed-form expressions for the cubic polynomial coefficients are derived in the spectral domain and the performance analysis of the model is given in the time and frequency domains. We derive the closed-form performance bounds of such DDS using conventional metrics: rms and maximum absolute errors (MAE) and maximum spurious free dynamic range (SFDR) measured in the discrete time domain. The main advantages of the proposed PSAC are its simplicity, analytical tractability, and inherent numerical stability for high table resolutions. Detailed guidelines for a fixed-point implementation are given, based on the algebraic analysis of all quantization effects. The results are verified on 81 PSAC configurations with the output resolutions from 5 to 41 bits by using a bit-exact simulation. The VHDL implementation of a high-accuracy DDS based on the proposed PSAC with 28-bit input phase word and 32-bit output value achieves SFDR of its digital output signal between 180 and 207 dB, with a signal-to-noise ratio of 192 dB. Its implementation requires only one 18 kB block RAM and three 18-bit embedded multipliers in a typical field-programmable gate array (FPGA) device.

  1. High-Accuracy, Compact Scanning Method and Circuit for Resistive Sensor Arrays

    Directory of Open Access Journals (Sweden)

    Jong-Seok Kim

    2016-01-01

    Full Text Available The zero-potential scanning circuit is widely used as read-out circuit for resistive sensor arrays because it removes a well known problem: crosstalk current. The zero-potential scanning circuit can be divided into two groups based on type of row drivers. One type is a row driver using digital buffers. It can be easily implemented because of its simple structure, but we found that it can cause a large read-out error which originates from on-resistance of the digital buffers used in the row driver. The other type is a row driver composed of operational amplifiers. It, very accurately, reads the sensor resistance, but it uses a large number of operational amplifiers to drive rows of the sensor array; therefore, it severely increases the power consumption, cost, and system complexity. To resolve the inaccuracy or high complexity problems founded in those previous circuits, we propose a new row driver which uses only one operational amplifier to drive all rows of a sensor array with high accuracy. The measurement results with the proposed circuit to drive a 4 × 4 resistor array show that the maximum error is only 0.1% which is remarkably reduced from 30.7% of the previous counterpart.

  2. Assessing the Accuracy of Sentinel-3 SLSTR Sea-Surface Temperature Retrievals Using High Accuracy Infrared Radiiometers on Ships of Opportunity

    Science.gov (United States)

    Minnett, P. J.; Izaguirre, M. A.; Szcszodrak, M.; Williams, E.; Reynolds, R. M.

    2015-12-01

    The assessment of errors and uncertainties in satellite-derived SSTs can be achieved by comparisons with independent measurements of skin SST of high accuracy. Such validation measurements are provided by well-calibrated infrared radiometers mounted on ships. The second generation of Marine-Atmospheric Emitted Radiance Interferometers (M-AERIs) have recently been developed and two are now deployed on cruise ships of Royal Caribbean Cruise Lines that operate in the Caribbean Sea, North Atlantic and Mediterranean Sea. In addition, two Infrared SST Autonomous Radiometers (ISARs) are mounted alternately on a vehicle transporter of NYK Lines that crosses the Pacific Ocean between Japan and the USA. Both M-AERIs and ISARs are self-calibrating radiometers having two internal blackbody cavities to provide at-sea calibration of the measured radiances, and the accuracy of the internal calibration is periodically determined by measurements of a NIST-traceable blackbody cavity in the laboratory. This provides SI-traceability for the at-sea measurements. It is anticipated that these sensors will be deployed during the next several years and will be available for the validation of the SLSTRs on Sentinel-3a and -3b.

  3. Brochopulmonary dysplasia: New high resolution computed tomography scorting system and correlation between the high resolution computed tomography score and clinical severity

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sumi; Kim, Woo Sun; Cheon, Jung Eun; Kim, Han Suk; Lee, Whal; Jung, Ah Young; Kim, In One; Choi, Jung Hwan [Seoul National University College of Medicine, Seoul (KR)

    2013-04-15

    To develop an high resolution computed tomography (HRCT) scoring system for the assessment of bronchopulmonary dysplasia (BPD) and determine its usefulness as compared with the chest radiographic score. Forty-two very low-birth-weight preterm infants with BPD (25 male, 17 female) were prospectively evaluated with HRCT performed at the mean age of 39.1-week postmenstrual age. Clinical severity of BPD was categorized as mild, moderate or severe. The HRCT score (0-36) of each patient was the sum of the number of bronchopulmonary segments with 1) hyperaeration and 2) parenchymal lesions (linear lesions, segmental atelectasis, consolidation and architectural distortion), respectively. We compared the HRCT scores with the chest radiographic scores (the Toce system) in terms of correlation with clinical severity. The HRCT score had good interobserver (r = 0.969, p < 0.001) and intraobserver (r = 0.986, p < 0.001) reproducibility. The HRCT score showed better correlation (r = 0.646, p < 0.001) with the clinical severity of BPD than the chest radiographic score (r = 0.410, p = 0.007). The hyperaeration score showed better correlation (r = 0.738, p < 0.001) with the clinical severity of BPD than the parenchymal score (r = 0.523, p < 0.001). We have developed a new HRCT scoring system for BPD based on the quantitative evaluation of pulmonary abnormalities of BPD consisting of the hyperaeration score and the parenchymal score. The HRCT score shows better correlation with the clinical severity of BPD than the radiographic score.

  4. Comparative analysis of the processing accuracy of high strength metal sheets by AWJ, laser and plasma

    Science.gov (United States)

    Radu, M. C.; Schnakovszky, C.; Herghelegiu, E.; Tampu, N. C.; Zichil, V.

    2016-08-01

    Experimental tests were carried out on two high-strength steel materials (Ramor 400 and Ramor 550). Quantification of the dimensional accuracy was achieved by measuring the deviations from some geometric parameters of part (two lengths and two radii). It was found that in case of Ramor 400 steel, at the jet inlet, the deviations from the part radii are quite small for all the three analysed processes. Instead for the linear dimensions, the deviations are small only in case of laser cutting. At the jet outlet, the deviations raised in small amount compared to those obtained at the jet inlet for both materials as well as for all the three processes. Related to Ramor 550 steel, at the jet inlet the deviations from the part radii are very small in case of AWJ and laser cutting but larger in case of plasma cutting. At the jet outlet, the deviations from the part radii are very small for all processes; in case of linear dimensions, there was obtained very small deviations only in the case of laser processing, the other two processes leading to very large deviations.

  5. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes

    Science.gov (United States)

    Zhang, Yichi; Liang, Xiao Ying; Liu, Shu; Lee, Jacky W. Y.; Bhaskar, Srinivasan; Lam, Dennis S. C.

    2016-01-01

    Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group for Laser Interference Biometry (ULIB) constants were evaluated and compared. Results. One hundred seventy-one eyes were enrolled. The Barrett Universal II formula had the lowest mean absolute error (MAE) and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas. The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas. The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.). Conclusions. Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas. For high myopic eyes, the Barrett Universal II formula may be a more suitable choice. PMID:27119018

  6. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes

    Directory of Open Access Journals (Sweden)

    Yichi Zhang

    2016-01-01

    Full Text Available Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL power calculation formulas for eyes with an axial length (AL greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II using User Group for Laser Interference Biometry (ULIB constants were evaluated and compared. Results. One hundred seventy-one eyes were enrolled. The Barrett Universal II formula had the lowest mean absolute error (MAE and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas. The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas. The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.. Conclusions. Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas. For high myopic eyes, the Barrett Universal II formula may be a more suitable choice.

  7. A high accuracy broadband measurement system for time resolved complex bioimpedance measurements.

    Science.gov (United States)

    Kaufmann, S; Malhotra, A; Ardelt, G; Ryschka, M

    2014-06-01

    Bioimpedance measurements are useful tools in biomedical engineering and life science. Bioimpedance is the electrical impedance of living tissue and can be used in the analysis of various physiological parameters. Bioimpedance is commonly measured by injecting a small well known alternating current via surface electrodes into an object under test and measuring the resultant surface voltages. It is non-invasive, painless and has no known hazards. This work presents a field programmable gate array based high accuracy broadband bioimpedance measurement system for time resolved bioimpedance measurements. The system is able to measure magnitude and phase of complex impedances under test in a frequency range of about 10-500 kHz with excitation currents from 10 µA to 5 mA. The overall measurement uncertainties stay below 1% for the impedance magnitude and below 0.5° for the phase in most measurement ranges. Furthermore, the described system has a sample rate of up to 3840 impedance spectra per second. The performance of the bioimpedance measurement system is demonstrated with a resistor based system calibration and with measurements on biological samples.

  8. GRACE Data-based High Accuracy Global Static Earth's Gravity Field Model

    Directory of Open Access Journals (Sweden)

    CHEN Qiujie

    2016-04-01

    Full Text Available To recover the highly accurate static earth's gravity field by using GRACE satellite data is one of the hot topics in geodesy. Since linearization errors of dynamic approach quickly increase when extending satellite arc length, we established a modified dynamic approach for processing GRACE orbit and range-rate measurements in this paper, which treated orbit observations of the twin GRACE satellites as approximate values for linearization. Using the GRACE data spanning the period Jan. 2003 to Dec. 2010, containing satellite attitudes, orbits, range-rate, and non-conservative forces, we developed two global static gravity field models. One is the unconstrained solution called Tongji-Dyn01s complete to degree and order 180; the other one is the Tongji-Dyn01k model computed by using Kaula constraint. The comparisons between our models and those latest GRACE-only models (including the AIUB-GRACE03, the GGM05S, the ITSG-Grace2014k and the Tongji-GRACE01 published by different international groups, and the external validations with marine gravity anomalies from DTU13 product and height anomalies from GPS/levelling data, were performed in this study. The results demonstrate that the Tongji-Dyn01s has the same accuracy level with those of the latest GRACE-only models, while the Tongji-Dyn01k model is closer to the EIGEN6C2 than the other GRACE-only models as a whole.

  9. High Accuracy Extraction of Respiratory Sinus Arrhythmia with Statistical Processing using Normal Distribution

    Science.gov (United States)

    Numata, Takashi; Ogawa, Yutaro; Yoshida, Lui; Kotani, Kiyoshi; Jimbo, Yasuhiko

    The autonomic nervous system is important in maintaining homeostasis by mediating the opposing effects of the sympathetic and parasympathetic nervous activity on organs. Although it is known that the amplitude of RSA (Respiratory Sinus Arrhythmia) is an index of parasympathetic nervous activity, it is difficult to estimate that activity in real-time in everyday situations. It is partly caused by body motions and extrasystoles. Also, automatic recognition of the R-wave on electrocardiograms is required for real-time analysis of RSA amplitude, there is an unresolved problem of false recognition of the R-wave. In this paper, we propose a method to evaluate the amplitude of RSA accurately using statistical processing with probabilistic models. Then, we estimate parasympathetic nervous activity during body motion and isometric exercise to examine the validity of the method. As a result, using the proposed method, we demonstrate that the amplitude of RSA can be extracted with false recognition of the R-wave. In addition, an appropriate threshold for the estimate is one or five percent because waveforms of RSA amplitude do not follow the abrupt changes of the parasympathetic nervous activity evoked by isometric exercise with the threshold at ten percent. Furthermore, the method using normal distribution is found to be more appropriate than that of chi-square distribution for statistical processing. Therefore, we expect that the proposed method can evaluate parasympathetic nervous activity with high accuracy in everyday situations.

  10. Raman spectroscopic determination of the molecular constants of the hydrogen isotopologues with high accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Krasch, Bennet; Mirz, Sebastian; Groessle, Robin [Karlsruhe Institute of Technology KIT (Germany). Institute for Technical Physics (ITEP), Tritium Laboratory Karlsruhe (TLK); Collaboration: KATRIN-Collaboration

    2016-07-01

    The interest in the thermodynamic properties of gases as the chemical equilibrium is faced by the challenge of time-consuming and technical extensive experimental setups. One possible solution is the derivation of these properties from the molecular constants. The rotational and vibrational movement of diatomic molecules, as the hydrogen isotopologues, is described by the concept of the rotational anharmonic oscillator. The molecular constants are the free parameters of this concept. Molecular constants themselves can be determined by measuring the line position of rotational and/or rotational transitions e.g. with Raman spectroscopy for hydrogen as it has been done since several years. In this contribution a Raman method was development to measure the molecular constant of the hydrogen isotopologues with high accuracy to obtain reliable results. But not only the method was development but also a complete measurement uncertainty budget was set up. The uncertainty budget contains all possible sources for uncertainties from the measurement period or the analysis process as well the contribution of each single uncertainty. The method and the uncertainty budget were exemplary tested on Deuterium.

  11. Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer

    Directory of Open Access Journals (Sweden)

    Akifumi Takanabe

    2017-02-01

    Full Text Available A fast, high-accuracy universal polarimeter was developed using a charge-coupled device (CCD spectrometer (CCD-HAUP, to carry out simultaneous optical anisotropic (linear birefringence, LB; linear dichroism, LD and chiroptical (circular birefringence, CB; circular dichroism, CD measurements on single crystals without any pretreatment, in the visible region between 400–680 nm. The principle of the HAUP method is to measure the intensities of emergent light passing through a polarizer, a crystal sample, and then an analyzer, as the azimuth angles of the polarizer and analyzer are independently altered. The CCD-HAUP has the unique feature that white transmitted light intensity can be measured using a CCD spectrometer, compared with the generalized HAUP (G-HAUP system in which monochromatic transmitted light is measured using a photomultiplier. The CCD-HAUP measurements across the entire wavelength region are completed within the G-HAUP measurement time for a single wavelength. The CCD-HAUP drastically reduces the measurement time for a dataset to only 1.5 h, from the 24 h required for the G-HAUP system. LB, LD, CB, and CD measurements of single crystals of α-quartz and enantiomeric photomechanical salicylidenephenylethylamines before, during, and after ultraviolet light irradiation show results comparable to those obtained using the G-HAUP system. The newly developed system is very effective for samples susceptible to degradation induced by external stimuli, such as light and heat.

  12. Statistical downscaling of precipitation using local regression and high accuracy surface modeling method

    Science.gov (United States)

    Zhao, Na; Yue, Tianxiang; Zhou, Xun; Zhao, Mingwei; Liu, Yu; Du, Zhengping; Zhang, Lili

    2017-07-01

    Downscaling precipitation is required in local scale climate impact studies. In this paper, a statistical downscaling scheme was presented with a combination of geographically weighted regression (GWR) model and a recently developed method, high accuracy surface modeling method (HASM). This proposed method was compared with another downscaling method using the Coupled Model Intercomparison Project Phase 5 (CMIP5) database and ground-based data from 732 stations across China for the period 1976-2005. The residual which was produced by GWR was modified by comparing different interpolators including HASM, Kriging, inverse distance weighted method (IDW), and Spline. The spatial downscaling from 1° to 1-km grids for period 1976-2005 and future scenarios was achieved by using the proposed downscaling method. The prediction accuracy was assessed at two separate validation sites throughout China and Jiangxi Province on both annual and seasonal scales, with the root mean square error (RMSE), mean relative error (MRE), and mean absolute error (MAE). The results indicate that the developed model in this study outperforms the method that builds transfer function using the gauge values. There is a large improvement in the results when using a residual correction with meteorological station observations. In comparison with other three classical interpolators, HASM shows better performance in modifying the residual produced by local regression method. The success of the developed technique lies in the effective use of the datasets and the modification process of the residual by using HASM. The results from the future climate scenarios show that precipitation exhibits overall increasing trend from T1 (2011-2040) to T2 (2041-2070) and T2 to T3 (2071-2100) in RCP2.6, RCP4.5, and RCP8.5 emission scenarios. The most significant increase occurs in RCP8.5 from T2 to T3, while the lowest increase is found in RCP2.6 from T2 to T3, increased by 47.11 and 2.12 mm, respectively.

  13. Statistical downscaling of precipitation using local regression and high accuracy surface modeling method

    Science.gov (United States)

    Zhao, Na; Yue, Tianxiang; Zhou, Xun; Zhao, Mingwei; Liu, Yu; Du, Zhengping; Zhang, Lili

    2016-03-01

    Downscaling precipitation is required in local scale climate impact studies. In this paper, a statistical downscaling scheme was presented with a combination of geographically weighted regression (GWR) model and a recently developed method, high accuracy surface modeling method (HASM). This proposed method was compared with another downscaling method using the Coupled Model Intercomparison Project Phase 5 (CMIP5) database and ground-based data from 732 stations across China for the period 1976-2005. The residual which was produced by GWR was modified by comparing different interpolators including HASM, Kriging, inverse distance weighted method (IDW), and Spline. The spatial downscaling from 1° to 1-km grids for period 1976-2005 and future scenarios was achieved by using the proposed downscaling method. The prediction accuracy was assessed at two separate validation sites throughout China and Jiangxi Province on both annual and seasonal scales, with the root mean square error (RMSE), mean relative error (MRE), and mean absolute error (MAE). The results indicate that the developed model in this study outperforms the method that builds transfer function using the gauge values. There is a large improvement in the results when using a residual correction with meteorological station observations. In comparison with other three classical interpolators, HASM shows better performance in modifying the residual produced by local regression method. The success of the developed technique lies in the effective use of the datasets and the modification process of the residual by using HASM. The results from the future climate scenarios show that precipitation exhibits overall increasing trend from T1 (2011-2040) to T2 (2041-2070) and T2 to T3 (2071-2100) in RCP2.6, RCP4.5, and RCP8.5 emission scenarios. The most significant increase occurs in RCP8.5 from T2 to T3, while the lowest increase is found in RCP2.6 from T2 to T3, increased by 47.11 and 2.12 mm, respectively.

  14. Correlation of delta high-resolution computed tomography (HRCT) score with delta clinical variables in early systemic sclerosis (SSc) patients

    Science.gov (United States)

    Euathrongchit, Juntima; Wattanawittawas, Pittaporn; Kasitanon, Nuntana

    2016-01-01

    Background The correlation of changes (delta: Δ) of high-resolution computed tomography (HRCT) score with the Δ of other clinical variables has not been well studied. The purpose of this study was to determine the correlation of Δ HRCT score with Δ percent predicted forced vital capacity (%pFVC), Δ modified Rodnan Skin Score (mRSS), Δ erythrocyte sedimentation rate (ESR), and Δ percent of oxygen saturation at room air (%SpO2) in patients with early systemic sclerosis (SSc). Methods We used an inception cohort of early-SSc patients seen at the Rheumatology Clinic, Chiang Mai University, Thailand, between January 2010 and June 2014. All patients underwent HRCT at study entry and every 12 months thereafter. Thirty-one SSc patients who underwent pulmonary function test (PFT) within 12 weeks of their corresponding HRCT at baseline and last visit were identified. The extent of ground glass (GG), lung fibrosis (Fib), bronchiectasis (B), and honeycombing (HC) was scored, and then aggregated to produce a total (t) HRCT score. Results Mean ± SD age and disease duration from non-Raynaud’s phenomenon (NRP) to undergo HRCT at baseline were 52.2±8.8 years and 11.7±7.1 months, respectively. Seventeen (54.8%) patients were female and 20 (64.5%) were classified as dcSSc. The mean ± SD interval between the two HRCT tests was 16.0±7.2 months. The Δ HRCT scores [total fibrosis scores (t-Fib), total bronchiectasis scores (t-B), and total HRCT score (t-HRCT) scores] and Δ mRSS, but not Δ %pFVC, showed significant change over the observation period. We found significant correlation of Δ total honeycombing scores (t-HC) with Δ ESR (r=−0.44, P<0.05), and Δ t-Fib with Δ %SpO2 (r=−0.38, P<0.05). However, no significant correlation of any Δ HRCT scores with Δ %pFVC and Δ mRSS were observed. Conclusions In this study, the changes in the HRCT scores were greater than %pFVC; this, along with their correlations with the changes in ESR and %SpO2, suggest that HRCT

  15. The Effect of Transient Students' Scores on the Norm of One High School's Standardized Basic Skills Test Battery.

    Science.gov (United States)

    Hill, Carolyn Stevens

    The effect of the standardized test scores of transient students on the mean of the 9th, 10th, and 11th grade standardized test scores of a school was studied. The groups used in the study were grades 9, 10, and 11 at a new high school in Clarksburg (West Virginia). The study was conducted in the spring of 1998. Groups consisted of 204 9th…

  16. Geometric Accuracy Investigations of SEVIRI High Resolution Visible (HRV) Level 1.5 Imagery

    National Research Council Canada - National Science Library

    Sultan Kocaman Aksakal

    2013-01-01

    .... In a joint project between the Swiss GCOS Office and ETH Zurich, geometric accuracy and temporal stability of 1-km resolution HRV channel imagery of SEVIRI have been evaluated over Switzerland...

  17. The regulatory benefits of high levels of affect perception accuracy: a process analysis of reactions to stressors in daily life.

    Science.gov (United States)

    Robinson, Michael D; Moeller, Sara K; Buchholz, Maria M; Boyd, Ryan L; Troop-Gordon, Wendy

    2012-08-01

    Individuals attuned to affective signals from the environment may possess an advantage in the emotion-regulation realm. In two studies (total n = 151), individual differences in affective perception accuracy were assessed in an objective, performance-based manner. Subsequently, the same individuals completed daily diary protocols in which daily stressor levels were reported as well as problematic states shown to be stress-reactive in previous studies. In both studies, individual differences in affect perception accuracy interacted with daily stressor levels to predict the problematic outcomes. Daily stressors precipitated problematic reactions--whether depressive feelings (study 1) or somatic symptoms (study 2)--at low levels of affect perception accuracy, but did not do so at high levels of affect perception accuracy. The findings support a regulatory view of such perceptual abilities. Implications for understanding emotion regulation processes, emotional intelligence, and individual differences in reactivity are discussed.

  18. [Accuracy of liquid-based cytology in diagnosis of high-grade squamous cervical intraepithelial neoplasia].

    Science.gov (United States)

    Li, Min; Mei, Ping; Luo, Dong-lan; Wang, Xiao-bing; Liu, Yan-hui

    2012-04-01

    To investigate factors affecting the diagnostic accuracy of cervical liquid-based cytology for high-grade squamous intraepithelial lesion (HSIL). A retrospective evaluation of cytological and histological slides was performed in 415 patients who had cytological HSIL between 2007 and 2010. Among 42 209 cases screened by ThinPrep liquid-based cytology, 415 cases (1.0%) of HSIL were eventually identified. The mean age of HSIL patients was 41.6 years, and 30-49 years were the most common age group. Among 415 cases, 325 patients had available histological diagnosis as follows: 23 (7.1%) negative, 22 (6.8%) CIN1/HPV, 223 (68.6%) CIN2/CIN3, and 57 (17.5%) squamous cell carcinoma (SCC). The positive predictive values of HSIL to predict CIN2 (or higher grade of dysplasia) and CIN1 were 86.2% (280/325) and 92.9% (302/325), respectively. Inadequate biopsy, reactive glandular cells, islet atrophy, chemo/radiotherapy and others were responsible for the cytologically false-positive diagnosis. Fifty-seven (17.5%) cases of HSIL had a histological diagnosis of SCC. The possible causes of misdiagnosis were social factors, under-recognized cytological features of poorly-differentiated SCC and absence of typical diagnostic features in cytology slides. Cytology of HSIL has a high positive predictive value for the presence of CIN2/CIN3 and SCC. Cytologists and gynecologists should be aware of the diagnostic pitfalls that may lead to the discrepancy between cytology and histology.

  19. Achieving numerical accuracy and high performance using recursive tile LU factorization with partial pivoting

    KAUST Repository

    Dongarra, Jack

    2013-09-18

    The LU factorization is an important numerical algorithm for solving systems of linear equations in science and engineering and is a characteristic of many dense linear algebra computations. For example, it has become the de facto numerical algorithm implemented within the LINPACK benchmark to rank the most powerful supercomputers in the world, collected by the TOP500 website. Multicore processors continue to present challenges to the development of fast and robust numerical software due to the increasing levels of hardware parallelism and widening gap between core and memory speeds. In this context, the difficulty in developing new algorithms for the scientific community resides in the combination of two goals: achieving high performance while maintaining the accuracy of the numerical algorithm. This paper proposes a new approach for computing the LU factorization in parallel on multicore architectures, which not only improves the overall performance but also sustains the numerical quality of the standard LU factorization algorithm with partial pivoting. While the update of the trailing submatrix is computationally intensive and highly parallel, the inherently problematic portion of the LU factorization is the panel factorization due to its memory-bound characteristic as well as the atomicity of selecting the appropriate pivots. Our approach uses a parallel fine-grained recursive formulation of the panel factorization step and implements the update of the trailing submatrix with the tile algorithm. Based on conflict-free partitioning of the data and lockless synchronization mechanisms, our implementation lets the overall computation flow naturally without contention. The dynamic runtime system called QUARK is then able to schedule tasks with heterogeneous granularities and to transparently introduce algorithmic lookahead. The performance results of our implementation are competitive compared to the currently available software packages and libraries. For example

  20. Direct Georeferencing : a New Standard in Photogrammetry for High Accuracy Mapping

    Science.gov (United States)

    Rizaldy, A.; Firdaus, W.

    2012-07-01

    Direct georeferencing is a new method in photogrammetry, especially in the digital camera era. Theoretically, this method does not require ground control points (GCP) and the Aerial Triangulation (AT), to process aerial photography into ground coordinates. Compared with the old method, this method has three main advantages: faster data processing, simple workflow and less expensive project, at the same accuracy. Direct georeferencing using two devices, GPS and IMU. GPS recording the camera coordinates (X, Y, Z), and IMU recording the camera orientation (omega, phi, kappa). Both parameters merged into Exterior Orientation (EO) parameter. This parameters required for next steps in the photogrammetric projects, such as stereocompilation, DSM generation, orthorectification and mosaic. Accuracy of this method was tested on topographic map project in Medan, Indonesia. Large-format digital camera Ultracam X from Vexcel is used, while the GPS / IMU is IGI AeroControl. 19 Independent Check Point (ICP) were used to determine the accuracy. Horizontal accuracy is 0.356 meters and vertical accuracy is 0.483 meters. Data with this accuracy can be used for 1:2.500 map scale project.

  1. HIGH ACCURACY FINITE VOLUME ELEMENT METHOD FOR TWO-POINT BOUNDARY VALUE PROBLEM OF SECOND ORDER ORDINARY DIFFERENTIAL EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    王同科

    2002-01-01

    In this paper, a high accuracy finite volume element method is presented for two-point boundary value problem of second order ordinary differential equation, which differs fromthe high order generalized difference methods. It is proved that the method has optimal order er-ror estimate O(h3) in H1 norm. Finally, two examples show that the method is effective.

  2. Numerical simulation for accuracy of velocity analysis in small-scale high-resolution marine multichannel seismic technology

    Science.gov (United States)

    Luo, Di; Cai, Feng; Wu, Zhiqiang

    2017-06-01

    When used with large energy sparkers, marine multichannel small-scale high-resolution seismic detection technology has a high resolution, high-detection precision, a wide applicable range, and is very flexible. Positive results have been achieved in submarine geological research, particularly in the investigation of marine gas hydrates. However, the amount of traveltime difference information is reduced for the velocity analysis under conditions of a shorter spread length, thus leading to poorer focusing of the velocity spectrum energy group and a lower accuracy of the velocity analysis. It is thus currently debatable whether the velocity analysis accuracy of short-arrangement multichannel seismic detection technology is able to meet the requirements of practical application in natural gas hydrate exploration. Therefore, in this study the bottom boundary of gas hydrates (Bottom Simulating Reflector, BSR) is used to conduct numerical simulation to discuss the accuracy of the velocity analysis related to such technology. Results show that a higher dominant frequency and smaller sampling interval are not only able to improve the seismic resolution, but they also compensate for the defects of the short-arrangement, thereby improving the accuracy of the velocity analysis. In conclusion, the accuracy of the velocity analysis in this small-scale, high-resolution, multi-channel seismic detection technology meets the requirements of natural gas hydrate exploration.

  3. Towards Building Reliable, High-Accuracy Solar Irradiance Database For Arid Climates

    Science.gov (United States)

    Munawwar, S.; Ghedira, H.

    2012-12-01

    Middle East's growing interest in renewable energy has led to increased activity in solar technology development with the recent commissioning of several utility-scale solar power projects and many other commercial installations across the Arabian Peninsula. The region, lying in a virtually rainless sunny belt with a typical daily average solar radiation exceeding 6 kWh/m2, is also one of the most promising candidates for solar energy deployment. However, it is not the availability of resource, but its characterization and reasonably accurate assessment that determines the application potential. Solar irradiance, magnitude and variability inclusive, is the key input in assessing the economic feasibility of a solar system. The accuracy of such data is of critical importance for realistic on-site performance estimates. This contribution aims to identify the key stages in developing a robust solar database for desert climate by focusing on the challenges that an arid environment presents to parameterization of solar irradiance attenuating factors. Adjustments are proposed based on the currently available resource assessment tools to produce high quality data for assessing bankability. Establishing and maintaining ground solar irradiance measurements is an expensive affair and fairly limited in time (recently operational) and space (fewer sites) in the Gulf region. Developers within solar technology industry, therefore, rely on solar radiation models and satellite-derived data for prompt resource assessment needs. It is imperative that such estimation tools are as accurate as possible. While purely empirical models have been widely researched and validated in the Arabian Peninsula's solar modeling history, they are known to be intrinsically site-specific. A primal step to modeling is an in-depth understanding of the region's climate, identifying the key players attenuating radiation and their appropriate characterization to determine solar irradiance. Physical approach

  4. Finite-element solution of the coupled-channel Schrödinger equation using high-order accuracy approximations

    Science.gov (United States)

    Abrashkevich, A. G.; Abrashkevich, D. G.; Kaschiev, M. S.; Puzynin, I. V.

    1995-01-01

    The finite element method (FEM) is applied to solve the bound state (Sturm-Liouville) problem for systems of ordinary linear second-order differential equations. The convergence, accuracy and the range of applicability of the high-order FEM approximations (up to tenth order) are studied systematically on the basis of numerical experiments for a wide set of quantum-mechanical problems. The analytical and tabular forms of giving the coefficients of differential equations are considered. The Dirichlet and Neumann boundary conditions are discussed. It is shown that the use of the FEM high-order accuracy approximations considerably increases the accuracy of the FE solutions with substantial reduction of the requirements on the computational resources. The results of the FEM calculations for various quantum-mechanical problems dealing with different types of potentials used in atomic and molecular calculations (including the hydrogen atom in a homogeneous magnetic field) are shown to be well converged and highly accurate.

  5. Experienced and inexperienced observers achieved relatively high within-observer agreement on video mobility scoring of dairy cows.

    Science.gov (United States)

    Garcia, E; König, K; Allesen-Holm, B H; Klaas, I C; Amigo, J M; Bro, R; Enevoldsen, C

    2015-07-01

    Assessment of lameness prevalence and severity requires visual evaluation of thelocomotion of a cow. Welfare schemes including locomotion assessments are increasingly being adopted, and more farmers and their veterinarians might implement a locomotion-scoring routine together. However, high within-observer agreement is a prerequisite for obtaining valid mobility scorings, and within-observer agreement cannot be estimated in a barn, because the gait of cows is dynamic and may change between 2 occasions. The objective of this study was to estimate the within-observer agreement according to the observers' educational background and experience with cattle, based on video recordings with very diverse types of gait. Groups of farmers, bovine veterinarians, first- and fourth-year veterinary students, researchers, and cattle-inexperienced sensory assessors evaluated mobility using a 5-point mobility score system developed specifically for walking cows (n=102 observers). The evaluation sessions were similar for all groups, lasted 75 min, and were organized as follows: introduction, test A, short training session, break, and test B. In total, video recordings of 22 cows were displayed twice in a random order (11 cows in each test × 2 replicates). Data were analyzed applying kappa coefficient, logistic regression, and testing for random effects of observers. The crude estimates of 95% confidence interval for weighted kappa in test A and B ranged, respectively, from 0.76 to 0.80 and 0.70 to 0.75. When adjusting for the fixed effects of video sample and gait scoring preferences, the probability of assigning the same mobility score twice to the same cow varied from 55% (sensory assessors) to 72% (fourth-year veterinary students). The random effect of the individual observers was negligible. That is, in general observers could categorize the mobility characteristics of cows quite well. Observers who preferred to assess the attributes back arch or the overall mobility score

  6. Automated, high accuracy classification of Parkinsonian disorders: a pattern recognition approach.

    Directory of Open Access Journals (Sweden)

    Andre F Marquand

    Full Text Available Progressive supranuclear palsy (PSP, multiple system atrophy (MSA and idiopathic Parkinson's disease (IPD can be clinically indistinguishable, especially in the early stages, despite distinct patterns of molecular pathology. Structural neuroimaging holds promise for providing objective biomarkers for discriminating these diseases at the single subject level but all studies to date have reported incomplete separation of disease groups. In this study, we employed multi-class pattern recognition to assess the value of anatomical patterns derived from a widely available structural neuroimaging sequence for automated classification of these disorders. To achieve this, 17 patients with PSP, 14 with IPD and 19 with MSA were scanned using structural MRI along with 19 healthy controls (HCs. An advanced probabilistic pattern recognition approach was employed to evaluate the diagnostic value of several pre-defined anatomical patterns for discriminating the disorders, including: (i a subcortical motor network; (ii each of its component regions and (iii the whole brain. All disease groups could be discriminated simultaneously with high accuracy using the subcortical motor network. The region providing the most accurate predictions overall was the midbrain/brainstem, which discriminated all disease groups from one another and from HCs. The subcortical network also produced more accurate predictions than the whole brain and all of its constituent regions. PSP was accurately predicted from the midbrain/brainstem, cerebellum and all basal ganglia compartments; MSA from the midbrain/brainstem and cerebellum and IPD from the midbrain/brainstem only. This study demonstrates that automated analysis of structural MRI can accurately predict diagnosis in individual patients with Parkinsonian disorders, and identifies distinct patterns of regional atrophy particularly useful for this process.

  7. Functional knowledge transfer for high-accuracy prediction of under-studied biological processes.

    Directory of Open Access Journals (Sweden)

    Christopher Y Park

    Full Text Available A key challenge in genetics is identifying the functional roles of genes in pathways. Numerous functional genomics techniques (e.g. machine learning that predict protein function have been developed to address this question. These methods generally build from existing annotations of genes to pathways and thus are often unable to identify additional genes participating in processes that are not already well studied. Many of these processes are well studied in some organism, but not necessarily in an investigator's organism of interest. Sequence-based search methods (e.g. BLAST have been used to transfer such annotation information between organisms. We demonstrate that functional genomics can complement traditional sequence similarity to improve the transfer of gene annotations between organisms. Our method transfers annotations only when functionally appropriate as determined by genomic data and can be used with any prediction algorithm to combine transferred gene function knowledge with organism-specific high-throughput data to enable accurate function prediction. We show that diverse state-of-art machine learning algorithms leveraging functional knowledge transfer (FKT dramatically improve their accuracy in predicting gene-pathway membership, particularly for processes with little experimental knowledge in an organism. We also show that our method compares favorably to annotation transfer by sequence similarity. Next, we deploy FKT with state-of-the-art SVM classifier to predict novel genes to 11,000 biological processes across six diverse organisms and expand the coverage of accurate function predictions to processes that are often ignored because of a dearth of annotated genes in an organism. Finally, we perform in vivo experimental investigation in Danio rerio and confirm the regulatory role of our top predicted novel gene, wnt5b, in leftward cell migration during heart development. FKT is immediately applicable to many bioinformatics

  8. Autotaxin activity has a high accuracy to diagnose intrahepatic cholestasis of pregnancy.

    Science.gov (United States)

    Kremer, Andreas E; Bolier, Ruth; Dixon, Peter H; Geenes, Victoria; Chambers, Jenny; Tolenaars, Dagmar; Ris-Stalpers, Carrie; Kaess, Bernhard M; Rust, Christian; van der Post, Joris A; Williamson, Catherine; Beuers, Ulrich; Oude Elferink, Ronald P J

    2015-04-01

    Intrahepatic cholestasis of pregnancy (ICP) is defined by pruritus, elevated total fasting serum bile salts (TBS) and transaminases, and an increased risk of adverse fetal outcome. An accurate diagnostic marker is needed. Increased serum autotaxin correlates with cholestasis-associated pruritus. We aimed at unraveling the diagnostic accuracy of autotaxin in ICP. Serum samples and placental tissue were collected from 44 women with uncomplicated pregnancies and 105 with pruritus and/or elevated serum transaminases. Autotaxin serum levels were quantified enzymatically and by Western blotting, autotaxin gene expression by quantitative PCR. Serum autotaxin was increased in ICP (mean ± SD: 43.5 ± 18.2 nmol ml(-1)min(-1), n=55, ppregnancy (16.8 ± 6.7 nmol ml(-1)min(-1), n=33), pre-eclampsia complicated by HELLP-syndrome (16.8 ± 8.9 nmol ml(-1)min(-1), n=17), and pregnant controls (19.6 ± 5.7 nmol ml(-1)min(-1), n=44). Longitudinal analysis during pregnancy revealed a marked rise in serum autotaxin with onset of ICP-related pruritus. Serum autotaxin was increased in women taking oral contraceptives. Increased serum autotaxin during ICP was not associated with increased autotaxin mRNA in placenta. With a cut-off value of 27.0 nmol ml(-1)min(-1), autotaxin had an excellent sensitivity and specificity in distinguishing ICP from other pruritic disorders or pre-eclampsia/HELLP-syndrome. Serum autotaxin displayed no circadian rhythm and was not influenced by food intake. Increased serum autotaxin activity represents a highly sensitive, specific and robust diagnostic marker of ICP, distinguishing ICP from other pruritic disorders of pregnancy and pregnancy-related liver diseases. Pregnancy and oral contraception increase serum autotaxin to a much lesser extent than ICP. Copyright © 2014 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  9. High accuracy solution of bi-directional wave propagation in continuum mechanics

    Science.gov (United States)

    Mulloth, Akhil; Sawant, Nilesh; Haider, Ijlal; Sharma, Nidhi; Sengupta, Tapan K.

    2015-10-01

    Solution of partial differential equations by numerical method is strongly affected due to numerical errors, which are caused mainly by deviation of numerical dispersion relation from the physical dispersion relation. To quantify and control such errors and obtain high accuracy solutions, we consider a class of problems which involve second derivative of unknowns with respect to time. Here, we analyse numerical metrics such as the numerical group velocity, numerical phase speed and the numerical amplification factor for different methods in solving the model bi-directional wave equation (BDWE). Such equations can be solved directly, for example, by Runge-Kutta-Nyström (RKN) method. Alternatively, the governing equation can be converted to a set of first order in time equations and then using four-stage fourth order Runge-Kutta (RK4) method for time integration. Spatial discretisation considered are the classical second and fourth order central difference schemes, along with Lele's central compact scheme for evaluating second derivatives. In another version, we have used Lele's scheme for evaluating first derivatives twice to obtain the second derivative. As BDWE represents non-dissipative, non-dispersive dynamics, we also consider the canonical problem of linearised rotating shallow water equation (LRSWE) in a new formulation involving second order derivative in time, which represents dispersive waves along with a stationary mode. The computations of LRSWE with RK4 and RKN methods for temporal discretisation and Lele's compact schemes for spatial discretisation are compared with computations performed with RK4 method for time discretisation and staggered compact scheme (SCS) for spatial discretisation by treating it as a set of three equations as reported in Rajpoot et al. (2012) [1].

  10. In-depth, high-accuracy proteomics of sea urchin tooth organic matrix

    Directory of Open Access Journals (Sweden)

    Mann Matthias

    2008-12-01

    Full Text Available Abstract Background The organic matrix contained in biominerals plays an important role in regulating mineralization and in determining biomineral properties. However, most components of biomineral matrices remain unknown at present. In sea urchin tooth, which is an important model for developmental biology and biomineralization, only few matrix components have been identified. The recent publication of the Strongylocentrotus purpuratus genome sequence rendered possible not only the identification of genes potentially coding for matrix proteins, but also the direct identification of proteins contained in matrices of skeletal elements by in-depth, high-accuracy proteomic analysis. Results We identified 138 proteins in the matrix of tooth powder. Only 56 of these proteins were previously identified in the matrices of test (shell and spine. Among the novel components was an interesting group of five proteins containing alanine- and proline-rich neutral or basic motifs separated by acidic glycine-rich motifs. In addition, four of the five proteins contained either one or two predicted Kazal protease inhibitor domains. The major components of tooth matrix were however largely identical to the set of spicule matrix proteins and MSP130-related proteins identified in test (shell and spine matrix. Comparison of the matrices of crushed teeth to intact teeth revealed a marked dilution of known intracrystalline matrix proteins and a concomitant increase in some intracellular proteins. Conclusion This report presents the most comprehensive list of sea urchin tooth matrix proteins available at present. The complex mixture of proteins identified may reflect many different aspects of the mineralization process. A comparison between intact tooth matrix, presumably containing odontoblast remnants, and crushed tooth matrix served to differentiate between matrix components and possible contributions of cellular remnants. Because LC-MS/MS-based methods directly

  11. High accuracy of arterial spin labeling perfusion imaging in differentiation of pilomyxoid from pilocytic astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, S.A.; Assadsangabi, R.; Hajmomenian, M.; Vossough, A. [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Santi, M. [Perelman School of Medicine of the University of Pennsylvania, Department of Pathology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States)

    2015-05-01

    Pilomyxoid astrocytoma (PMA) is a relatively new tumor entity which has been added to the 2007 WHO Classification of tumors of the central nervous system. The goal of this study is to utilize arterial spin labeling (ASL) perfusion imaging to differentiate PMA from pilocytic astrocytoma (PA). Pulsed ASL and conventional MRI sequences of patients with PMA and PA in the past 5 years were retrospectively evaluated. Patients with history of radiation or treatment with anti-angiogenic drugs were excluded. A total of 24 patients (9 PMA, 15 PA) were included. There were statistically significant differences between PMA and PA in mean tumor/gray matter (GM) cerebral blood flow (CBF) ratios (1.3 vs 0.4, p < 0.001) and maximum tumor/GM CBF ratio (2.3 vs 1, p < 0.001). Area under the receiver operating characteristic (ROC) curves for differentiation of PMA from PA was 0.91 using mean tumor CBF, 0.95 using mean tumor/GM CBF ratios, and 0.89 using maximum tumor/GM CBF. Using a threshold value of 0.91, the mean tumor/GM CBF ratio was able to diagnose PMA with 77 % sensitivity, 100 % specificity, and a threshold value of 0.7, provided 88 % sensitivity and 86 % specificity. There was no statistically significant difference between the two tumors in enhancement pattern (p = 0.33), internal architecture (p = 0.15), or apparent diffusion coefficient (ADC) values (p = 0.07). ASL imaging has high accuracy in differentiating PMA from PA. The result of this study may have important applications in prognostication and treatment planning especially in patients with less accessible tumors such as hypothalamic-chiasmatic gliomas. (orig.)

  12. High Resolution Ice Surface of the Ross Ice Shelf: Accuracy and Links to Basal Processes

    Science.gov (United States)

    Starke, S. E.

    2015-12-01

    We use airborne laser altimetry data from IcePod and IceBridge to map the surface across the Ross Ice Shelf in Antarctica. Laser altimetry and radar data is analyzed from the IcePod 2014 and 2015 field campaigns as well as IceBridge 2013. Icepod is a multi sensor suite that includes ice penetrating radars, a swath scanning laser, visible and IR cameras as well as GPS mounted on a LC-130. Using shallow ice radar data from both IcePod and IceBridge we identify the base of the ice shelf. Across the shelf we observe distinct areas of high reflectivity in the radar data suggesting basal crevassing. In some regions, the basal reflector is not well defined. Laser altimetry profiles correlate surface morphology with features at the base including basal crevasses and marine ice formed by freezing on to the base of the ice shelf. Building Digital Elevation Models (DEMs) from the laser altimetry data, we investigate the relationship between the surface expressions of these ice shelf dynamics including thickness changes, potential sites of marine ice at the base and basal morphology in regions where a well defined basal reflector does not exist in the radar profiles. We present accuracy of the IcePod laser altimetry dataset using ground control points and GPS grids from Greenland and Antarctica as well as Photogrammetric DEMs. Our laser altimetry analysis resolves sub-meter surface features which, combined with coincident radar, provides a link between basal processes and their surface expressions.

  13. The research of digital circuit system for high accuracy CCD of portable Raman spectrometer

    Science.gov (United States)

    Yin, Yu; Cui, Yongsheng; Zhang, Xiuda; Yan, Huimin

    2013-08-01

    The Raman spectrum technology is widely used for it can identify various types of molecular structure and material. The portable Raman spectrometer has become a hot direction of the spectrometer development nowadays for its convenience in handheld operation and real-time detection which is superior to traditional Raman spectrometer with heavy weight and bulky size. But there is still a gap for its measurement sensitivity between portable and traditional devices. However, portable Raman Spectrometer with Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) technology can enhance the Raman signal significantly by several orders of magnitude, giving consideration in both measurement sensitivity and mobility. This paper proposed a design and implementation of driver and digital circuit for high accuracy CCD sensor, which is core part of portable spectrometer. The main target of the whole design is to reduce the dark current generation rate and increase signal sensitivity during the long integration time, and in the weak signal environment. In this case, we use back-thinned CCD image sensor from Hamamatsu Corporation with high sensitivity, low noise and large dynamic range. In order to maximize this CCD sensor's performance and minimize the whole size of the device simultaneously to achieve the project indicators, we delicately designed a peripheral circuit for the CCD sensor. The design is mainly composed with multi-voltage circuit, sequential generation circuit, driving circuit and A/D transition parts. As the most important power supply circuit, the multi-voltage circuits with 12 independent voltages are designed with reference power supply IC and set to specified voltage value by the amplifier making up the low-pass filter, which allows the user to obtain a highly stable and accurate voltage with low noise. What's more, to make our design easy to debug, CPLD is selected to generate sequential signal. The A/D converter chip consists of a correlated

  14. Association between High Fat-low Carbohydrate Diet Score and Newly Diagnosed Type 2 Diabetes in Chinese Population

    NARCIS (Netherlands)

    Na, Y.; Feskens, E.J.M.; Li, Y.P.; Zhang, J.; Fu, P.; Ma, G.S.; Yang, X.G.

    2012-01-01

    Objective To study the association between high fat-low carbohydrate diet score and newly diagnosed type 2 diabetes in Chinese population. Methods Data about 20 717 subjects aged 45-59 years from the cross-sectional 2002 China National Nutrition and Health Survey were analyzed. High fat-low

  15. Association between High Fat-low Carbohydrate Diet Score and Newly Diagnosed Type 2 Diabetes in Chinese Population

    NARCIS (Netherlands)

    Na, Y.; Feskens, E.J.M.; Li, Y.P.; Zhang, J.; Fu, P.; Ma, G.S.; Yang, X.G.

    2012-01-01

    Objective To study the association between high fat-low carbohydrate diet score and newly diagnosed type 2 diabetes in Chinese population. Methods Data about 20 717 subjects aged 45-59 years from the cross-sectional 2002 China National Nutrition and Health Survey were analyzed. High fat-low carbohyd

  16. High Reliability of a Scoring System for Implant Position in Undisplaced Femoral Neck Fractures

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Bartholin, Marie-Louise L; Weber, Kolja;

    2016-01-01

    OBJECTIVES: The aim of this study was to evaluate the intra-rater and inter-rater reliability of a scoring system for internal fixation (SIFA) in undisplaced femoral neck fractures (FNF). DESIGN: A reproducibility study with a historical consecutive cohort. SETTING: The patients were all treated...... of the screw position in femoral head had the largest difference of acceptable positioning, when comparing visual assessment with the measured. CONCLUSIONS: The SIFA scoring system demonstrates substantial intra-rater and inter-rater reliability (kappa (0.51-0.78), when raters make measurements of radiographs......, but lower reliability (kappa 0.13-0.78) when raters visually assess the radiographs without measuring. The SIFA scoring system should be assessed on a large cohort for correlation with clinical evaluation....

  17. Millimeter-Wave Airborne Interferometry for High-accuracy Topography Mapping

    Science.gov (United States)

    Moller, D.; Hensley, S.; Wu, X.; Rodriguez, E.

    2011-12-01

    sensor geometry, bandwidth and number of channels needed for SWOT cal/val cannot be met within the framework of GLISTIN-A or a similar interface to UAVSAR. To address SWOT's cal/val requirements, the Ka-band SWOT Phenomenology Airborne Radar (KaSPAR) builds upon GLISTIN-A heritage and is the primary payload of the AirSWOT program. KaSPAR is a unique system with multiple temporal and cross-track baselines to fully characterize the scattering and statistics expected from SWOT, provide data for developing classification algorithms, and understanding instrument performance over the vast variety of scenes that SWOT will encounter. Furthermore a >5km swath high-accuracy WSE mapping capability provides the framework to translate traditional point or profile measurements to the spatial framework that SWOT will measure. Specific measurements from the integrated AirSWOT assembly are 1) WSE maps over a 5km swath with <3cm mean error at 100m x 100m postings (for ocean surface at 6m/s wind speed), 2) 2-D slope maps derived from WSE maps and 3) shoreline delineation at 10m resolution. These measurements will be made at resolutions exceeding that of SWOT to better characterize corrections for the spaceborne sensor.

  18. HIGH-ACCURACY BAND TO BAND REGISTRATION METHOD FOR MULTI-SPECTRAL IMAGES OF HJ-1A/B

    Institute of Scientific and Technical Information of China (English)

    Lu Hao; Liu Tuanjie; Zhao Haiqing

    2012-01-01

    Band-to-band registration accuracy is an important parameter of multispectral data.A novel band-to-band registration approach with high precision is proposed for the multi-spectral images of HJ-1A/B.Firstly,the main causes resulted in misregistration are analyzed,and a high-order polynomial model is proposed.Secondly,a phase fringe filtering technique is employed to Phase Correlation Method based on Singular Value Decomposition (SVD-PCM) for reducing the noise in phase difference matrix.Then,experiments are carried out to build nonlinear registration models,and images of green band and red band are aligned to blue band with an accuracy of 0.1 pixels,while near infrared band with an accuracy of 0.2 pixels.

  19. High-Accuracy HLA Type Inference from Whole-Genome Sequencing Data Using Population Reference Graphs.

    Directory of Open Access Journals (Sweden)

    Alexander T Dilthey

    2016-10-01

    Full Text Available Genetic variation at the Human Leucocyte Antigen (HLA genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG framework. First, we construct a PRG for 46 (mostly HLA genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1 and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data. Of 158 alleles tested, we correctly infer 157 alleles (99.4%. We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30-250 CPU hours per sample remain a

  20. High-Accuracy HLA Type Inference from Whole-Genome Sequencing Data Using Population Reference Graphs.

    Science.gov (United States)

    Dilthey, Alexander T; Gourraud, Pierre-Antoine; Mentzer, Alexander J; Cereb, Nezih; Iqbal, Zamin; McVean, Gil

    2016-10-01

    Genetic variation at the Human Leucocyte Antigen (HLA) genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing) as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG) framework. First, we construct a PRG for 46 (mostly HLA) genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1) and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data). Of 158 alleles tested, we correctly infer 157 alleles (99.4%). We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30-250 CPU hours per sample) remain a significant

  1. 冠状动脉CT造影SYNTAX积分可重复性及准确性研究%The repeatability and accuracy of coronary CT angiography SYNTAX score

    Institute of Scientific and Technical Information of China (English)

    王忠民; 刘煜昊; 朱绍成; 徐予; 朱中玉; 高传玉

    2015-01-01

    目的:分析冠状动脉CT造影SYNTAX积分的可重复性及准确性,为其临床应用奠定基础。方法回顾性分析2012年2月至2013年2月行冠状动脉CT造影及侵入性冠状动脉造影检查的223例患者,分别计算两种方法得出的SYNTAX积分。采用Kappa分析法评价CT冠状动脉造影SYNTAX积分的可重复性。以侵入性冠状动脉造影为金标准,进行配对样本t检验、Spearman's rank test分析及Bland-Altman法分析CT冠状动脉造影SYNTAX积分的准确性。采用双侧P<0.05为差异有统计学意义。结果 CT冠状动脉造影SYNTAX积分读者间及读者内的可重复性极好,K值均>0.75。侵入性冠状动脉造影与CT冠状动脉造影无显著统计学差异(平均值19.44vs.20.40, P=0.295)。相关分析显示两者之间显著正相关(r=0.931,P<0.001)。结论 CT冠状动脉造影SYNTAX积分可重复性好,准确性高。基于CT冠状动脉造影SYNTAX积分值得今后在临床上加以推广应用。%ObjectiveTo determine the repeatability and accuracy of coronary CT angiography SYNTAX score.Methods We evaluated 223 patients that underwent coronary CT angiography (CTA) and subsequent invasive coronary angiography (ICA). Vessel-specific SYNTAX scores, as well as global SYNTAX scores, were calculated from CTA and ICA in blinded fashion by independent and experienced investigators. Kappa analysis was used to analysis the repeatability of CTA. Paired samplet test, Spearman’s rank test analysis and Bland-Altman analysis method was used to analysis the accuracy of CTA. With double sideP0.75. There was no statistically significant difference between ICA and CTA (average: 19.44vs. 20.40,P=0.295). Correlation analysis showed significantly positive correlation between the two methods (r=0.931,P<0.931).ConclusionSYNTAX score derived from CTA demonstrate excellent repeatability and accuracy, which is worthy of clinical application.

  2. Primary graft dysfunction; possible evaluation by high resolution computed tomography, and suggestions for a scoring system

    DEFF Research Database (Denmark)

    Belmaati, Esther; Jensen, Claus; Kofoed, Klaus F

    2009-01-01

    /exclusion criteria of patients, pilot testing, and training investigators through review of disagreements, were possibilities suggested for decreasing inter/intra observer variability. Factors affecting the image attenuation (Hounsfield numbers) and thus, the reproducibility of CT densitometric measurements were...... of minimal influence. Studies have reported on how lung tissue images, derived by HRCT, can be scored and graded. There does not seem to be a golden standard for evaluating these images, which makes comparison between methods challenging. These scoring systems assess the presence, severity, and extent...

  3. Accuracy analysis of continuous deformation monitoring using BeiDou Navigation Satellite System at middle and high latitudes in China

    Science.gov (United States)

    Jiang, Weiping; Xi, Ruijie; Chen, Hua; Xiao, Yugang

    2017-02-01

    As BeiDou Navigation Satellite System (BDS) has been operational in the whole Asia-Pacific region, it means a new GNSS system with a different satellite orbit structure will become available for deformation monitoring in the future. Conversely, GNSS deformation monitoring data are always processed with a regular interval to form displacement time series for deformation analysis, where the interval can neither be too long from the time perspective nor too short from the precision of determined displacements angle. In this paper, two experimental platforms were designed, with one being at mid-latitude and another at higher latitude in China. BDS data processing software was also developed for investigating the accuracy of continuous deformation monitoring using current in-orbit BDS satellites. Data over 20 days at both platforms were obtained and were processed every 2, 4 and 6 h to generate 3 displacement time series for comparison. The results show that with the current in-orbit BDS satellites, in the mid-latitude area it is easy to achieve accuracy of 1 mm in horizontal component and 2-3 mm in vertical component; the accuracy could be further improved to approximately 1 mm in both horizontal and vertical directions when combined BDS/GPS measurements are employed. At higher latitude, however, the results are not as good as expected due to poor satellite geometry, even the 6 h solutions could only achieve accuracy of 4-6 and 6-10 mm in horizontal and vertical components, respectively, which implies that it may not be applicable to very high-precision deformation monitoring at high latitude using the current BDS. With the integration of BDS and GPS observations, however, in 4-h session, the accuracy can achieve 2 mm in horizontal component and 4 mm in vertical component, which would be an optimal choice for high-accuracy structural deformation monitoring at high latitude.

  4. Usefulness of Serum Albumin Concentration to Predict High Coronary SYNTAX Score and In-Hospital Mortality in Patients With Acute Coronary Syndrome.

    Science.gov (United States)

    Kurtul, Alparslan; Murat, Sani Namik; Yarlioglues, Mikail; Duran, Mustafa; Ocek, Adil Hakan; Koseoglu, Cemal; Celık, Ibrahim Etem; Kilic, Alparslan; Aksoy, Ozlem

    2016-01-01

    High SYNTAX score is a predictor of adverse cardiovascular events, including mortality, in acute coronary syndromes (ACSs). Decreased serum albumin (SA) concentration is associated with an increased risk of cardiovascular events. We aimed to investigate whether SA levels at admission are associated with high SYNTAX score and in-hospital mortality in patients with ACS. The study included 1303 patients with ACS who underwent coronary angiography (CA). The patients were divided into 2 groups as high SYNTAX score (≥33) and lower SYNTAX score (≤32). Baseline SA levels were significantly lower in patients with high SYNTAX score than with lower SYNTAX score (3.46 ± 0.42 mg/dL vs 3.97±0.37 mg/dL, respectively; P SYNTAX score (odds ratio 4.329, 95% confidence interval 2.028-8.264; P SYNTAX score, and SA (SYNTAX score and in-hospital mortality in ACS.

  5. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Alkadhi, Hatem; Desbiolles, Lotus; Frauenfelder, Thomas; Schertler, Thomas; Husmann, Lars; Marincek, Borut; Leschka, Sebastian [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Plass, Andre; Vachenauer, Robert; Grunenfelder, Juerg; Genoni, Michele [Clinic for Cardiovascular Surgery, Zurich (Switzerland); Gaemperli, Oliver; Schepis, Tiziano [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Center for Integrative Human Physiology, Zurich (Switzerland)

    2006-12-15

    The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1{+-}11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14{+-}9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter {>=}1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3{+-}3.9 kg/m{sup 2} (range 22.4-36.3 kg/m{sup 2}), mean heart rate during CT was 70.3{+-}14.2 bpm (range 47-102 bpm), and mean Agatston score was 821{+-}904 (range 0-3,110). Image quality was diagnostic (scores 1-3) in 98.6% (414/420) of segments (mean image quality score 1.68{+-}0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control. (orig.)

  6. Spectroscopy of H3+ based on a new high-accuracy global potential energy surface.

    Science.gov (United States)

    Polyansky, Oleg L; Alijah, Alexander; Zobov, Nikolai F; Mizus, Irina I; Ovsyannikov, Roman I; Tennyson, Jonathan; Lodi, Lorenzo; Szidarovszky, Tamás; Császár, Attila G

    2012-11-13

    The molecular ion H(3)(+) is the simplest polyatomic and poly-electronic molecular system, and its spectrum constitutes an important benchmark for which precise answers can be obtained ab initio from the equations of quantum mechanics. Significant progress in the computation of the ro-vibrational spectrum of H(3)(+) is discussed. A new, global potential energy surface (PES) based on ab initio points computed with an average accuracy of 0.01 cm(-1) relative to the non-relativistic limit has recently been constructed. An analytical representation of these points is provided, exhibiting a standard deviation of 0.097 cm(-1). Problems with earlier fits are discussed. The new PES is used for the computation of transition frequencies. Recently measured lines at visible wavelengths combined with previously determined infrared ro-vibrational data show that an accuracy of the order of 0.1 cm(-1) is achieved by these computations. In order to achieve this degree of accuracy, relativistic, adiabatic and non-adiabatic effects must be properly accounted for. The accuracy of these calculations facilitates the reassignment of some measured lines, further reducing the standard deviation between experiment and theory.

  7. Analysis of the plasmodium falciparum proteome by high-accuracy mass spectrometry

    DEFF Research Database (Denmark)

    Lasonder, Edwin; Ishihama, Yasushi; Andersen, Jens S;

    2002-01-01

    -accuracy (average deviation less than 0.02 Da at 1,000 Da) mass spectrometric proteome analysis of selected stages of the human malaria parasite Plasmodium falciparum. The analysis revealed 1,289 proteins of which 714 proteins were identified in asexual blood stages, 931 in gametocytes and 645 in gametes. The last...

  8. Literature survey of high-impact journals revealed reporting weaknesses in abstracts of diagnostic accuracy studies

    NARCIS (Netherlands)

    Korevaar, Daniël A; Cohen, Jérémie F; Hooft, Lotty; Bossuyt, Patrick M M

    2015-01-01

    OBJECTIVES: Informative journal abstracts are crucial for the identification and initial appraisal of studies. We aimed to evaluate the informativeness of abstracts of diagnostic accuracy studies. STUDY DESIGN AND SETTING: PubMed was searched for reports of studies that had evaluated the diagnostic

  9. The effect of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players.

    Science.gov (United States)

    Lyons, Mark; Al-Nakeeb, Yahya; Hankey, Joanne; Nevill, Alan

    2013-01-01

    Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player's achievement motivation characteristics. 13 expert (7 male, 6 female) and 17 non-expert (13 male, 4 female) tennis players participated in the study. Groundstroke accuracy was assessed using the modified Loughborough Tennis Skills Test. Fatigue was induced using the Loughborough Intermittent Tennis Test with moderate (70%) and high-intensities (90%) set as a percentage of peak heart rate (attained during a tennis-specific maximal hitting sprint test). Ratings of perceived exertion were used as an adjunct to the monitoring of heart rate. Achievement goal indicators for each player were assessed using the 2 x 2 Achievement Goals Questionnaire for Sport in an effort to examine if this personality characteristic provides insight into how players perform under moderate and high-intensity fatigue conditions. A series of mixed ANOVA's revealed significant fatigue effects on groundstroke accuracy regardless of expertise. The expert players however, maintained better groundstroke accuracy across all conditions compared to the novice players. Nevertheless, in both groups, performance following high-intensity fatigue deteriorated compared to performance at rest and performance while moderately fatigued. Groundstroke accuracy under moderate levels of fatigue was equivalent to that at rest. Fatigue effects were also similar regardless of gender. No fatigue by expertise, or fatigue by gender interactions were found. Fatigue effects were also equivalent regardless of player's achievement goal indicators. Future research is required to explore the effects of fatigue on performance in tennis

  10. Amplitude-integrated electroencephalographic activity is suppressed in preterm infants with high scores on illness severity

    NARCIS (Netherlands)

    ter Horst, Hendrik J.; Jongbloed-Pereboom, Marjolein; van Eykern, Leo A.; Bos, Arend F.

    2011-01-01

    Background: The neonatal acute physiology score. SNAP-II, reflects the severity of illness in newborns. In term newborns, amplitude integrated EEG (aEEG), is depressed following asphyxia. In preterm infants aEEG is discontinuous, and therefore more difficult to assess compared to term infants. Aims:

  11. High Profile Football Players' Reading at a Research University: ACT Scores, Interview Responses, and Personal Preferences

    Science.gov (United States)

    Townsend, Martha

    2013-01-01

    This qualitative case study examines the reading acumen of a cohort of twenty-six senior football players at a Midwestern public research university. Data related to three indices--ACT scores, interview responses, and personal preferences--were collected as part of a larger IRB-approved study aimed at determining the factors that led to the entire…

  12. Using College Admission Test Scores to Clarify High School Placement. Leading Indicator Spotlight

    Science.gov (United States)

    Flug, Susanna

    2010-01-01

    In "Beyond Test Scores: Leading Indicators for Education," Foley and colleagues (2008) define leading indicators as those that "provide early signals of progress toward academic achievement" (p. 1) and stress that educators "need leading indicators to help them see the direction their efforts are going in and to take…

  13. Beating the Odds: A Low Equalized Assessed Valuation Elementary School with High Standardized Test Scores

    Science.gov (United States)

    Levin, Brian

    2011-01-01

    This mixed methods study examines what makes Bluffview Elementary School a success as measured by the ISAT, the mandated state test of Illinois. Despite national reports of achievement gaps and low test scores, Bluffview Elementary has shown sustained success in educating children. This paper reviews how Bluffview Elementary students are achieving…

  14. High inter-tester reliability of the new mobility score in patients with hip fracture

    DEFF Research Database (Denmark)

    Kristensen, M.T.; Bandholm, T.; Foss, N.B.;

    2008-01-01

    OBJECTIVE: To assess the inter-tester reliability of the New Mobility Score in patients with acute hip fracture. DESIGN: An inter-tester reliability study. SUBJECTS: Forty-eight consecutive patients with acute hip fracture at a median age of 84 (interquartile range, 76-89) years; 40 admitted from...

  15. Getting into a Russell Group University: High Scores and Private Schooling

    Science.gov (United States)

    Hemsley-Brown, Jane

    2015-01-01

    Despite substantial prior research on higher education choice, top universities in the UK continue to stand accused of favouring socio-economically advantaged students, to the detriment of those from poorer backgrounds. The objectives of this study are to test whether students with the same or equivalent entry scores are more or less likely to…

  16. High-accuracy real-time automatic thresholding for centroid tracker

    Science.gov (United States)

    Zhang, Ye; Wang, Yanjie

    2006-01-01

    Many of the video image trackers today use the centroid as the tracking point. In engineering, a target's centroid is computed from a binary image to reduce the processing time. Hence thresholding of gray level image to binary image is a decisive step in centroid tracking. How to choose the feat thresholds in clutter is still an intractability problem unsolved today. This paper introduces a high-accuracy real-time automatic thresholding method for centroid tracker. It works well for variety types of target tracking in clutter. The core of this method is to get the entire information contained in the histogram, such as the number of the peaks, their height, position and other properties in the histogram. Combine with this histogram analysis; we can get several key pairs of peaks which can include the target and the background around it and use the method of Otsu to get intensity thresholds from them. According to the thresholds, we can gain the binary image and get the centroid from it. To track the target, the paper also suggests subjoining an eyeshot-window, just like our eyes focus on a target, we will not miss it unless it is out of our eyeshot, the impression will help us to extract the target in clutter and track it and we will wait its emergence since it has been covered. To obtain the impression, the paper offers a idea comes from the method of Snakes; it give a great help for us to get a glancing size, so that we can compare the size of the object in the current frame with the former. If the change is little, we consider the object has been tracked well. Otherwise, if the change is bigger than usual, we should analyze the inflection in the histogram to find out what happened to the object. In general, what we have to do is turning the analysis into codes for the tracker to determine a feat threshold. The paper will show the steps in detail. The paper also discusses the hardware architecture which can meet the speed requirement.

  17. High-accuracy, high-resolution gravity profiles from 2 years of the Geosat Exact Repeat Mission

    Science.gov (United States)

    Sandwell, David T.; Mcadoo, David C.

    1990-01-01

    Satellite altimeter data from the first 44 repeat cycles (2 years) of the Geosat Exact Repeat Mission (EWRM) were averaged to improve accuracy, resolution and coverage of the marine gravity field. Individual 17-day repeat cycles were first edited and differentiated, resulting in the along-track vertical deflection (i.e., gravity disturbance). To increase the signal-to-noise ratio, 44 of these cycles were then averaged to form a single highly accurate vertical deflection profile. The largest contribution to the vertical deflection error is short-wavelength altimeter noise and longer-wavelength oceanographic variability; the combined noise level is typically 6 microrad. Both types of noise are reduced by averaging many repeat cycles. Over most ocean areas the uncertainty of the average profile is less than 1 microrad which corresponds to 1 mgal of along-track gravity disturbance. However, in areas of seasonal ice coverage, its uncertainty can exceed 5 microrad. To assess the resolution of individual and average Geosat gravity profiles, the cross-spectral analysis technique was applied to repeat profiles. Individual Geosat repeat cycles are coherent (greater than 0.5) for wavelengths greater than about 30 km and become increasingly incoherent at shorter wavelengths.

  18. The Effects of Individual or Group Guidelines on the Calibration Accuracy and Achievement of High School Biology Students

    Science.gov (United States)

    Bol, Linda; Hacker, Douglas J.; Walck, Camilla C.; Nunnery, John A.

    2012-01-01

    A 2 x 2 factorial design was employed in a quasi-experiment to investigate the effects of guidelines in group or individual settings on the calibration accuracy and achievement of 82 high school biology students. Significant main effects indicated that calibration practice with guidelines and practice in group settings increased prediction and…

  19. NCACO-score: An effective main-chain dependent scoring function for structure modeling

    Directory of Open Access Journals (Sweden)

    Dong Xiaoxi

    2011-05-01

    Full Text Available Abstract Background Development of effective scoring functions is a critical component to the success of protein structure modeling. Previously, many efforts have been dedicated to the development of scoring functions. Despite these efforts, development of an effective scoring function that can achieve both good accuracy and fast speed still presents a grand challenge. Results Based on a coarse-grained representation of a protein structure by using only four main-chain atoms: N, Cα, C and O, we develop a knowledge-based scoring function, called NCACO-score, that integrates different structural information to rapidly model protein structure from sequence. In testing on the Decoys'R'Us sets, we found that NCACO-score can effectively recognize native conformers from their decoys. Furthermore, we demonstrate that NCACO-score can effectively guide fragment assembly for protein structure prediction, which has achieved a good performance in building the structure models for hard targets from CASP8 in terms of both accuracy and speed. Conclusions Although NCACO-score is developed based on a coarse-grained model, it is able to discriminate native conformers from decoy conformers with high accuracy. NCACO is a very effective scoring function for structure modeling.

  20. Accuracy of High-Resolution MRI with Lumen Distention in Rectal Cancer Staging and Circumferential Margin Involvement Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Iannicelli, Elsa; Di Renzo, Sara [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ferri, Mario [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Pilozzi, Emanuela [Department of Clinical and Molecular Sciences, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Di Girolamo, Marco; Sapori, Alessandra [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Ziparo, Vincenzo [Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); David, Vincenzo [Radiology Institute, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy); Department of Surgical and Medical Sciences and Translational Medicine, Faculty of Medicine and Psychology, University of Rome, Sapienza, Sant' Andrea Hospital, Rome 00189 (Italy)

    2014-07-01

    To evaluate the accuracy of magnetic resonance imaging (MRI) with lumen distention for rectal cancer staging and circumferential resection margin (CRM) involvement prediction. Seventy-three patients with primary rectal cancer underwent high-resolution MRI with a phased-array coil performed using 60-80 mL room air rectal distention, 1-3 weeks before surgery. MRI results were compared to postoperative histopathological findings. The overall MRI T staging accuracy was calculated. CRM involvement prediction and the N staging, the accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were assessed for each T stage. The agreement between MRI and histological results was assessed using weighted-kappa statistics. The overall MRI accuracy for T staging was 93.6% (k = 0.85). The accuracy, sensitivity, specificity, PPV and NPV for each T stage were as follows: 91.8%, 86.2%, 95.5%, 92.6% and 91.3% for the group ≤ T2; 90.4%, 94.6%, 86.1%, 87.5% and 94% for T3; 98,6%, 85.7%, 100%, 100% and 98.5% for T4, respectively. The predictive CRM accuracy was 94.5% (k = 0.86); the sensitivity, specificity, PPV and NPV were 89.5%, 96.3%, 89.5%, and 96.3% respectively. The N staging accuracy was 68.49% (k = 0.4). MRI performed with rectal lumen distention has proved to be an effective technique both for rectal cancer staging and involved CRM predicting.

  1. Real-time displacement measurement with large range and high accuracy using sinusoidal phase modulating laser diode interferometer

    Institute of Scientific and Technical Information of China (English)

    Guotian He; Xiangzhao Wang; Aijun Zeng; Feng Tang; Bingjie Huang

    2007-01-01

    To resolve the conflict of large measurement range and high accuracy in the existing real-time displacement measurement laser diode (LD) interferometers, a novel real-time displacement measurement LD interferometry is proposed and its measurement principle is analyzed. By use of a new phase demodulation algorithm and a new phase compensation lgorithm of real-time phase unwrapping, the measurement accuracy is improved, and the measurement range is enlarged to a few wavelengths. In experiments, the peak-to-peak amplitude of the speaker vibration was 2361.7 nm, and the repeatability was 2.56 nm. The measurement time was less than 26μs.

  2. Automated Essay Scoring

    Directory of Open Access Journals (Sweden)

    Semire DIKLI

    2006-01-01

    Full Text Available Automated Essay Scoring Semire DIKLI Florida State University Tallahassee, FL, USA ABSTRACT The impacts of computers on writing have been widely studied for three decades. Even basic computers functions, i.e. word processing, have been of great assistance to writers in modifying their essays. The research on Automated Essay Scoring (AES has revealed that computers have the capacity to function as a more effective cognitive tool (Attali, 2004. AES is defined as the computer technology that evaluates and scores the written prose (Shermis & Barrera, 2002; Shermis & Burstein, 2003; Shermis, Raymat, & Barrera, 2003. Revision and feedback are essential aspects of the writing process. Students need to receive feedback in order to increase their writing quality. However, responding to student papers can be a burden for teachers. Particularly if they have large number of students and if they assign frequent writing assignments, providing individual feedback to student essays might be quite time consuming. AES systems can be very useful because they can provide the student with a score as well as feedback within seconds (Page, 2003. Four types of AES systems, which are widely used by testing companies, universities, and public schools: Project Essay Grader (PEG, Intelligent Essay Assessor (IEA, E-rater, and IntelliMetric. AES is a developing technology. Many AES systems are used to overcome time, cost, and generalizability issues in writing assessment. The accuracy and reliability of these systems have been proven to be high. The search for excellence in machine scoring of essays is continuing and numerous studies are being conducted to improve the effectiveness of the AES systems.

  3. Predicting high risk of exacerbations in bronchiectasis: the E-FACED score

    Science.gov (United States)

    Martinez-Garcia, MA; Athanazio, RA; Girón, R; Máiz-Carro, L; de la Rosa, D; Olveira, C; de Gracia, J; Vendrell, M; Prados-Sánchez, C; Gramblicka, G; Corso Pereira, M; Lundgren, FL; Fernandes De Figueiredo, M; Arancibia, F; Rached, SZ

    2017-01-01

    Background Although the FACED score has demonstrated a great prognostic capacity in bronchiectasis, it does not include the number or severity of exacerbations as a separate variable, which is important in the natural history of these patients. Objective Construction and external validation of a new index, the E-FACED, to evaluate the predictive capacity of exacerbations and mortality. Methods The new score was constructed on the basis of the complete cohort for the construction of the original FACED score, while the external validation was undertaken with six cohorts from three countries (Brazil, Argentina, and Chile). The main outcome was the number of annual exacerbations/hospitalizations, with all-cause and respiratory-related deaths as the secondary outcomes. A statistical evaluation comprised the relative weight and ideal cut-off point for the number or severity of the exacerbations and was incorporated into the FACED score (E-FACED). The results obtained after the application of FACED and E-FACED were compared in both the cohorts. Results A total of 1,470 patients with bronchiectasis (819 from the construction cohorts and 651 from the external validation cohorts) were followed up for 5 years after diagnosis. The best cut-off point was at least two exacerbations in the previous year (two additional points), meaning that the E-FACED has nine points of growing severity. E-FACED presented an excellent prognostic capacity for exacerbations (areas under the receiver operating characteristic curve: 0.82 for at least two exacerbations in 1 year and 0.87 for at least one hospitalization in 1 year) that was statistically better than that of the FACED score (0.72 and 0.78, P<0.05, respectively). The predictive capacities for all-cause and respiratory mortality were 0.87 and 0.86, respectively, with both being similar to those of the FACED. Conclusion E-FACED score significantly increases the FACED capacity to predict future yearly exacerbations while maintaining the

  4. High-accuracy extrapolated ab initio thermochemistry. II. Minor improvements to the protocol and a vital simplification

    Science.gov (United States)

    Bomble, Yannick J.; Vázquez, Juana; Kállay, Mihály; Michauk, Christine; Szalay, Péter G.; Császár, Attila G.; Gauss, Jürgen; Stanton, John F.

    2006-08-01

    The recently developed high-accuracy extrapolated ab initio thermochemistry method for theoretical thermochemistry, which is intimately related to other high-precision protocols such as the Weizmann-3 and focal-point approaches, is revisited. Some minor improvements in theoretical rigor are introduced which do not lead to any significant additional computational overhead, but are shown to have a negligible overall effect on the accuracy. In addition, the method is extended to completely treat electron correlation effects up to pentuple excitations. The use of an approximate treatment of quadruple and pentuple excitations is suggested; the former as a pragmatic approximation for standard cases and the latter when extremely high accuracy is required. For a test suite of molecules that have rather precisely known enthalpies of formation {as taken from the active thermochemical tables of Ruscic and co-workers [Lecture Notes in Computer Science, edited by M. Parashar (Springer, Berlin, 2002), Vol. 2536, pp. 25-38; J. Phys. Chem. A 108, 9979 (2004)]}, the largest deviations between theory and experiment are 0.52, -0.70, and 0.51kJmol-1 for the latter three methods, respectively. Some perspective is provided on this level of accuracy, and sources of remaining systematic deficiencies in the approaches are discussed.

  5. High coronary artery calcium score affects clinical outcome despite normal stress myocardial perfusion imaging and normal left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Madsen, Claus Juul; Andersen, Kim F; Zerahn, Bo

    2013-01-01

    Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS...

  6. Predicting high risk of exacerbations in bronchiectasis: the E-FACED score

    Directory of Open Access Journals (Sweden)

    Martinez-Garcia MA

    2017-01-01

    Full Text Available Martinez-Garcia MA,1,2 Athanazio RA,3 Girón R,4 Máiz-Carro L,5 de la Rosa D,6 Olveira C,7 de Gracia J,2,8 Vendrell M,9 Prados-Sánchez C,10 Gramblicka G,11 Corso Pereira M,12 Lundgren FL,13 Fernandes De Figueiredo M,14 Arancibia F,15 Rached SZ3 1Pulmonary Service, Polytechnic and University La Fe Hospital, Valencia, Spain; 2CIBERes, CIBER de Enfermedades Respiratorias. Madrid. Spain; 3Pulmonary Division, Heart Institute (Incor, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo; 4Pneumology Service, Hospital La Princesa, 5Pneumology Service, Hospital Ramón y Cajal, Madrid, 6Pneumology Unit, Hospital Plató, Barcelona, 7Pneumology, Málaga Regional University Hospital, Instituto de Biomedicina de Málaga (IBIMA, Málaga University, Spain; 8Pneumology Service, Hospital Vall d’Hebron, Barcelona, 9Bronchiectasis Group IDIBGI, Dr. Trueta University Hospital. UdG. Ciberes CB06/06/0030, 10Unidad de Fibrosis Quística y Bronquiectasias. Hospital Universitario La Paz. Madrid. Spain; 11Pneumology Service, Hospital del Tórax Dr A Cetrángolo, Buenos Aires, Argentina; 12Pneumology Service, Universidade Estadual de Campinas UNICAMP, Sao Paulo, 13Pneumology Service, Hospital Octávio de Freitas, Recife, 14Pneumology Service, Hospital de Messejana, Fortaleza, Brazil; 15Pneumology Service, Instituto Nacional del Tórax, Santiago de Chile, Chile Background: Although the FACED score has demonstrated a great prognostic capacity in bronchiectasis, it does not include the number or severity of exacerbations as a separate variable, which is important in the natural history of these patients.Objective: Construction and external validation of a new index, the E-FACED, to evaluate the predictive capacity of exacerbations and mortality.Methods: The new score was constructed on the basis of the complete cohort for the construction of the original FACED score, while the external validation was undertaken with six cohorts from three

  7. SFOL Pulse: A High Accuracy DME Pulse for Alternative Aircraft Position and Navigation

    Directory of Open Access Journals (Sweden)

    Euiho Kim

    2017-09-01

    Full Text Available In the Federal Aviation Administration’s (FAA performance based navigation strategy announced in 2016, the FAA stated that it would retain and expand the Distance Measuring Equipment (DME infrastructure to ensure resilient aircraft navigation capability during the event of a Global Navigation Satellite System (GNSS outage. However, the main drawback of the DME as a GNSS back up system is that it requires a significant expansion of the current DME ground infrastructure due to its poor distance measuring accuracy over 100 m. The paper introduces a method to improve DME distance measuring accuracy by using a new DME pulse shape. The proposed pulse shape was developed by using Genetic Algorithms and is less susceptible to multipath effects so that the ranging error reduces by 36.0–77.3% when compared to the Gaussian and Smoothed Concave Polygon DME pulses, depending on noise environment.

  8. Friction compensation design based on state observer and adaptive law for high-accuracy positioning system

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Friction is one of the main factors that affect the positioning accuracy of motion system. Friction compensation based on friction model is usually adopted to eliminate the nonlinear effect of friction. This paper presents a proportional-plus-derivative (PD) feedback controller with a friction compensator based on LuGre friction model. We also design a state observer to observe the unknown state of LuGre friction model, and adopt a parameter adaptive law and off-line approximation to estimate the parameters of LuGre friction model. Comparative experiments are carried out among our proposed controller, PD controller with friction compensation based on classical friction model, and PD controller without friction compensation. Experimental results demonstrate that our proposed controller can achieve better performance, especially higher positioning accuracy.

  9. The European System for Cardiac Operative Risk Evaluation (EuroSCORE is not appropriate for withholding surgery in high-risk patients with aortic stenosis: a retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Légaré Jean-Francois

    2009-07-01

    Full Text Available Abstract Background The European System for Cardiac Operative Risk Evaluation (EuroSCORE is a widely used risk assessment tool in patients with severe aortic stenosis to determine operability and to select patients for alternative therapies such as transcatheter aortic valve implantation. The objective of this study was to determine the accuracy of the EuroSCORE in predicting mortality following aortic valve replacement (AVR. Methods The logistic EuroSCORE was determined for all consecutive patients that underwent conventional AVR between 1995 and 2005 at our institution. Provincial Vital Statistics were used to determine all-cause mortality. The accuracy of the prognostic risk prediction provided by logistic EuroSCORE was assessed by comparing observed and expected operative mortality. Results During the study period, a total of 1,421 patients underwent AVR including 237 patients (16.7% that had a logistic EuroSCORE > 20. Among these patients, the mean predicted operative mortality was 38.7% (SD = 18.1. The actual mortality of these patients was significantly lower than that predicted by EuroSCORE (11.4% vs. 38.7%, observed/expected ratio 0.29, 95% CI 0.15–0.52, P 20 (log rank P = 0.0001, approximately 60% are alive at five years. Conclusion Actual operative mortality in patients undergoing AVR is significantly lower than that predicted by the logistic EuroSCORE. Additionally, medium-term survival following AVR is acceptable in high-risk patients with EuroSCORE > 20. More accurate risk prediction models are needed for risk-stratifying patients with severe aortic stenosis.

  10. Ways to help Chinese Students in Senior High School improve language accuracy in writing

    Institute of Scientific and Technical Information of China (English)

    潘惠红

    2015-01-01

    <正>Introduction In Chinese ELT(English language teaching),as in other countries,both fluency and accuracy are considered important either in the teaching or assessment of writing.In this respect,the last decade has seen reforms in the College Entrance Examination in Guangdong Province.With two writing tasks being set as assessment,task one requires students to summarise Chinese language information into five English sentences while the

  11. A High-Accuracy Linear Conservative Difference Scheme for Rosenau-RLW Equation

    Directory of Open Access Journals (Sweden)

    Jinsong Hu

    2013-01-01

    Full Text Available We study the initial-boundary value problem for Rosenau-RLW equation. We propose a three-level linear finite difference scheme, which has the theoretical accuracy of Oτ2+h4. The scheme simulates two conservative properties of original problem well. The existence, uniqueness of difference solution, and a priori estimates in infinite norm are obtained. Furthermore, we analyze the convergence and stability of the scheme by energy method. At last, numerical experiments demonstrate the theoretical results.

  12. High-accuracy current measurement with low-cost shunts by means of dynamic error correction

    OpenAIRE

    Weßkamp, Patrick; Melbert, Joachim

    2016-01-01

    Measurement of electrical current is often performed by using shunt resistors. Thermal effects due to self-heating and ambient temperature variation limit the achievable accuracy, especially if low-cost shunt resistors with increased temperature coefficients are utilized. In this work, a compensation method is presented which takes static and dynamic temperature drift effects into account and provides a significant reduction of measurement error. A thermal model of the shunt...

  13. The effect of instructional methodology on high school students natural sciences standardized tests scores

    Science.gov (United States)

    Powell, P. E.

    Educators have recently come to consider inquiry based instruction as a more effective method of instruction than didactic instruction. Experience based learning theory suggests that student performance is linked to teaching method. However, research is limited on inquiry teaching and its effectiveness on preparing students to perform well on standardized tests. The purpose of the study to investigate whether one of these two teaching methodologies was more effective in increasing student performance on standardized science tests. The quasi experimental quantitative study was comprised of two stages. Stage 1 used a survey to identify teaching methods of a convenience sample of 57 teacher participants and determined level of inquiry used in instruction to place participants into instructional groups (the independent variable). Stage 2 used analysis of covariance (ANCOVA) to compare posttest scores on a standardized exam by teaching method. Additional analyses were conducted to examine the differences in science achievement by ethnicity, gender, and socioeconomic status by teaching methodology. Results demonstrated a statistically significant gain in test scores when taught using inquiry based instruction. Subpopulation analyses indicated all groups showed improved mean standardized test scores except African American students. The findings benefit teachers and students by presenting data supporting a method of content delivery that increases teacher efficacy and produces students with a greater cognition of science content that meets the school's mission and goals.

  14. A high-accuracy optical linear algebra processor for finite element applications

    Science.gov (United States)

    Casasent, D.; Taylor, B. K.

    1984-01-01

    Optical linear processors are computationally efficient computers for solving matrix-matrix and matrix-vector oriented problems. Optical system errors limit their dynamic range to 30-40 dB, which limits their accuray to 9-12 bits. Large problems, such as the finite element problem in structural mechanics (with tens or hundreds of thousands of variables) which can exploit the speed of optical processors, require the 32 bit accuracy obtainable from digital machines. To obtain this required 32 bit accuracy with an optical processor, the data can be digitally encoded, thereby reducing the dynamic range requirements of the optical system (i.e., decreasing the effect of optical errors on the data) while providing increased accuracy. This report describes a new digitally encoded optical linear algebra processor architecture for solving finite element and banded matrix-vector problems. A linear static plate bending case study is described which quantities the processor requirements. Multiplication by digital convolution is explained, and the digitally encoded optical processor architecture is advanced.

  15. Will it Blend? Visualization and Accuracy Evaluation of High-Resolution Fuzzy Vegetation Maps

    Science.gov (United States)

    Zlinszky, A.; Kania, A.

    2016-06-01

    Instead of assigning every map pixel to a single class, fuzzy classification includes information on the class assigned to each pixel but also the certainty of this class and the alternative possible classes based on fuzzy set theory. The advantages of fuzzy classification for vegetation mapping are well recognized, but the accuracy and uncertainty of fuzzy maps cannot be directly quantified with indices developed for hard-boundary categorizations. The rich information in such a map is impossible to convey with a single map product or accuracy figure. Here we introduce a suite of evaluation indices and visualization products for fuzzy maps generated with ensemble classifiers. We also propose a way of evaluating classwise prediction certainty with "dominance profiles" visualizing the number of pixels in bins according to the probability of the dominant class, also showing the probability of all the other classes. Together, these data products allow a quantitative understanding of the rich information in a fuzzy raster map both for individual classes and in terms of variability in space, and also establish the connection between spatially explicit class certainty and traditional accuracy metrics. These map products are directly comparable to widely used hard boundary evaluation procedures, support active learning-based iterative classification and can be applied for operational use.

  16. High accuracy integrated global positioning system/inertial navigation system LDRD: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Owen, T.E.; Meindl, M.A.; Fellerhoff, J.R.

    1997-03-01

    This report contains the results of a Sandia National Laboratories Directed Research and Development (LDRD) program to investigate the integration of Global Positioning System (GPS) and inertial navigation system (INS) technologies toward the goal of optimizing the navigational accuracy of the combined GPSANS system. The approach undertaken is to integrate the data from an INS, which has long term drifts, but excellent short term accuracy, with GPS carrier phase signal information, which is accurate to the sub-centimeter level, but requires continuous tracking of the GPS signals. The goal is to maintain a sub-meter accurate navigation solution while the vehicle is in motion by using the GPS measurements to estimate the INS navigation errors and then using the refined INS data to aid the GPS carrier phase cycle slip detection and correction and bridge dropouts in the GPS data. The work was expanded to look at GPS-based attitude determination, using multiple GPS receivers and antennas on a single platform, as a possible navigation aid. Efforts included not only the development of data processing algorithms and software, but also the collection and analysis of GPS and INS flight data aboard a Twin Otter aircraft. Finally, the application of improved navigation system accuracy to synthetic aperture radar (SAR) target location is examined.

  17. THE EFFECT OF MODERATE AND HIGH-INTENSITY FATIGUE ON GROUNDSTROKE ACCURACY IN EXPERT AND NON-EXPERT TENNIS PLAYERS

    Directory of Open Access Journals (Sweden)

    Mark Lyons

    2013-06-01

    Full Text Available Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player's achievement motivation characteristics. 13 expert (7 male, 6 female and 17 non-expert (13 male, 4 female tennis players participated in the study. Groundstroke accuracy was assessed using the modified Loughborough Tennis Skills Test. Fatigue was induced using the Loughborough Intermittent Tennis Test with moderate (70% and high-intensities (90% set as a percentage of peak heart rate (attained during a tennis-specific maximal hitting sprint test. Ratings of perceived exertion were used as an adjunct to the monitoring of heart rate. Achievement goal indicators for each player were assessed using the 2 x 2 Achievement Goals Questionnaire for Sport in an effort to examine if this personality characteristic provides insight into how players perform under moderate and high-intensity fatigue conditions. A series of mixed ANOVA's revealed significant fatigue effects on groundstroke accuracy regardless of expertise. The expert players however, maintained better groundstroke accuracy across all conditions compared to the novice players. Nevertheless, in both groups, performance following high-intensity fatigue deteriorated compared to performance at rest and performance while moderately fatigued. Groundstroke accuracy under moderate levels of fatigue was equivalent to that at rest. Fatigue effects were also similar regardless of gender. No fatigue by expertise, or fatigue by gender interactions were found. Fatigue effects were also equivalent regardless of player's achievement goal indicators. Future research is required to explore the effects of fatigue on

  18. Aggregate National Early Warning Score (NEWS) values are more important than high scores for a single vital signs parameter for discriminating the risk of adverse outcomes.

    Science.gov (United States)

    Jarvis, Stuart; Kovacs, Caroline; Briggs, Jim; Meredith, Paul; Schmidt, Paul E; Featherstone, Peter I; Prytherch, David R; Smith, Gary B

    2015-02-01

    The Royal College of Physicians (RCPL) National Early Warning Score (NEWS) escalates care to a doctor at NEWS values of ≥5 and when the score for any single vital sign is 3. We calculated the 24-h risk of serious clinical outcomes for vital signs observation sets with NEWS values of 3, 4 and 5, separately determining risks when the score did/did not include a single score of 3. We compared workloads generated by the RCPL's escalation protocol and for aggregate NEWS value alone. Aggregate NEWS values of 3 or 4 (n=142,282) formed 15.1% of all vital signs sets measured; those containing a single vital sign scoring 3 (n=36,207) constituted 3.8% of all sets. Aggregate NEWS values of either 3 or 4 with a component score of 3 have significantly lower risks (OR: 0.26 and 0.53) than an aggregate value of 5 (OR: 1.0). Escalating care to a doctor when any single component of NEWS scores 3 compared to when aggregate NEWS values ≥5, would have increased doctors' workload by 40% with only a small increase in detected adverse outcomes from 2.99 to 3.08 per day (a 3% improvement in detection). The recommended NEWS escalation protocol produces additional work for the bedside nurse and responding doctor, disproportionate to a modest benefit in increased detection of adverse outcomes. It may have significant ramifications for efficient staff resource allocation, distort patient safety focus and risk alarm fatigue. Our findings suggest that the RCPL escalation guidance warrants review. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Horizontal Positional Accuracy of Google Earth’s High-Resolution Imagery Archive

    Directory of Open Access Journals (Sweden)

    David Potere

    2008-12-01

    Full Text Available Google Earth now hosts high-resolution imagery that spans twenty percent of the Earth’s landmass and more than a third of the human population. This contemporary highresolution archive represents a significant, rapidly expanding, cost-free and largely unexploited resource for scientific inquiry. To increase the scientific utility of this archive, we address horizontal positional accuracy (georegistration by comparing Google Earth with Landsat GeoCover scenes over a global sample of 436 control points located in 109 cities worldwide. Landsat GeoCover is an orthorectified product with known absolute positional accuracy of less than 50 meters root-mean-squared error (RMSE. Relative to Landsat GeoCover, the 436 Google Earth control points have a positional accuracy of 39.7 meters RMSE (error magnitudes range from 0.4 to 171.6 meters. The control points derived from satellite imagery have an accuracy of 22.8 meters RMSE, which is significantly more accurate than the 48 control-points based on aerial photography (41.3 meters RMSE; t-test p-value < 0.01. The accuracy of control points in more-developed countries is 24.1 meters RMSE, which is significantly more accurate than the control points in developing countries (44.4 meters RMSE; t-test p-value < 0.01. These findings indicate that Google Earth highresolution imagery has a horizontal positional accuracy that is sufficient for assessing moderate-resolution remote sensing products across most of the world’s peri-urban areas.

  20. Usual and unusual histologic patterns of high Gleason score 8 to 10 adenocarcinoma of the prostate in needle biopsy tissue.

    Science.gov (United States)

    Gottipati, Srinivas; Warncke, Jason; Vollmer, Robin; Humphrey, Peter A

    2012-06-01

    High Gleason score 8 to 10 adenocarcinoma is the most aggressive and potentially lethal form of prostate cancer. The 2005 International Society of Urological Pathology (ISUP)-modified Gleason grading scheme defines several gland arrangements of high Gleason grade patterns 4 and 5. The aim of this investigation was to quantitate the frequency of the ISUP-defined high Gleason grade patterns in needle biopsy tissue, to determine the common admixtures and to characterize patterns not presented in the 2005 ISUP report. For patients who underwent radical prostatectomy, we analyzed for association of specific high-grade patterns in needle biopsy with extraprostatic extension in radical prostatectomy tissues. A total of 268 prostate needle biopsy cases with Gleason score of 8 to 10 were examined. A mean of 3.6 patterns (range, 1 to 8) were identified per case and only 12% of cases had a pure single pattern. Ill-defined glands with poorly formed lumina (at 57%) and fused microacinar glands (at 53%) comprised the predominant and most frequently admixed patterns. Single cells and single signet ring cells were present in 53% and 31% of cases, respectively. Additional patterns in order of frequency included cords (35%), cribriform glands (25%), sheets of cells (19%), chains (4%), glomeruloid (3%), comedonecrosis (2%), and hypernephromatoid (1 case=0.3%). Gleason score 8 to 10 carcinomas are typically extensive in needle core tissue, with a mean of 4.4 positive cores (range, 1 to 15 cores) per case. Only 14 cases (5%) had high-grade minimal carcinoma measuring ISUP report include single file growth, solid cylinders, and nested patterns. The single file pattern was present in 40% of cases, and the small solid nested pattern was detected in 24% of cases. One case displayed solid cylinders. Only the single file pattern was associated with extraprostatic extension at radical prostatectomy (P=0.005). These results show that the 2005 ISUP-defined patterns of high Gleason score 8 to 10

  1. A genome-wide linkage study of individuals with high scores on NEO personality traits.

    Science.gov (United States)

    Amin, N; Schuur, M; Gusareva, E S; Isaacs, A; Aulchenko, Y S; Kirichenko, A V; Zorkoltseva, I V; Axenovich, T I; Oostra, B A; Janssens, A C J W; van Duijn, C M

    2012-10-01

    The NEO-Five-Factor Inventory divides human personality traits into five dimensions: neuroticism, extraversion, openness, conscientiousness and agreeableness. In this study, we sought to identify regions harboring genes with large effects on the five NEO personality traits by performing genome-wide linkage analysis of individuals scoring in the extremes of these traits (>90th percentile). Affected-only linkage analysis was performed using an Illumina 6K linkage array in a family-based study, the Erasmus Rucphen Family study. We subsequently determined whether distinct, segregating haplotypes found with linkage analysis were associated with the trait of interest in the population. Finally, a dense single-nucleotide polymorphism genotyping array (Illumina 318K) was used to search for copy number variations (CNVs) in the associated regions. In the families with extreme phenotype scores, we found significant evidence of linkage for conscientiousness to 20p13 (rs1434789, log of odds (LOD)=5.86) and suggestive evidence of linkage (LOD >2.8) for neuroticism to 19q, 21q and 22q, extraversion to 1p, 1q, 9p and12q, openness to 12q and 19q, and agreeableness to 2p, 6q, 17q and 21q. Further analysis determined haplotypes in 21q22 for neuroticism (P-values = 0.009, 0.007), in 17q24 for agreeableness (marginal P-value = 0.018) and in 20p13 for conscientiousness (marginal P-values = 0.058, 0.038) segregating in families with large contributions to the LOD scores. No evidence for CNVs in any of the associated regions was found. Our findings imply that there may be genes with relatively large effects involved in personality traits, which may be identified with next-generation sequencing techniques.

  2. Error correction algorithm for high accuracy bio-impedance measurement in wearable healthcare applications.

    Science.gov (United States)

    Kubendran, Rajkumar; Lee, Seulki; Mitra, Srinjoy; Yazicioglu, Refet Firat

    2014-04-01

    Implantable and ambulatory measurement of physiological signals such as Bio-impedance using miniature biomedical devices needs careful tradeoff between limited power budget, measurement accuracy and complexity of implementation. This paper addresses this tradeoff through an extensive analysis of different stimulation and demodulation techniques for accurate Bio-impedance measurement. Three cases are considered for rigorous analysis of a generic impedance model, with multiple poles, which is stimulated using a square/sinusoidal current and demodulated using square/sinusoidal clock. For each case, the error in determining pole parameters (resistance and capacitance) is derived and compared. An error correction algorithm is proposed for square wave demodulation which reduces the peak estimation error from 9.3% to 1.3% for a simple tissue model. Simulation results in Matlab using ideal RC values show an average accuracy of for single pole and for two pole RC networks. Measurements using ideal components for a single pole model gives an overall and readings from saline phantom solution (primarily resistive) gives an . A Figure of Merit is derived based on ability to accurately resolve multiple poles in unknown impedance with minimal measurement points per decade, for given frequency range and supply current budget. This analysis is used to arrive at an optimal tradeoff between accuracy and power. Results indicate that the algorithm is generic and can be used for any application that involves resolving poles of an unknown impedance. It can be implemented as a post-processing technique for error correction or even incorporated into wearable signal monitoring ICs.

  3. A High-accuracy Approach to Pronunciation Prediction for Out-of-vocabulary English Word

    Institute of Scientific and Technical Information of China (English)

    WANG Hao; CHEN Gui-lin; XU Liang-xian

    2005-01-01

    Letter-to-Sound conversion is one of the fundamental issues in text-to-speech synthesis. In this paper, we address an approach to automatic prediction of word pronunciation. This approach combines example-based learning and dynamic-programming searching to predict sub-word pronunciation. Word pronunciation is formed by concatenating sub-word pronunciations. We conducted comparative experiments over a large-scale English dictionary. Experimental results show that this approach can achieve accuracy of 70.1%, which outperforms those published results.

  4. High accuracy wavelength locking of a DFB laser using tunable polarization interference filter

    Institute of Scientific and Technical Information of China (English)

    Xiyao Chen(陈曦曜); Jianping Xie(谢建平); Tianpeng Zhao(赵天鹏); Hai Ming(明海); Anting Wang(王安廷); Wencai Huang(黄文财); Liang Lü(吕亮); Lixin Xu(许立新)

    2003-01-01

    A temperature-tunable polarization interference filter (PIF) made of YVO4 crystal has been presented and applied for wavelength locking of a distributed feedback (DFB) semiconductor laser in dense wavelength-division-multiplexing (DWDM) optical communication systems. This new design offers a flexible way to monitor and then lock an operating wavelength of DFB laser to any preselected point without dead spots.The results show that the laser wavelength can be locked with accuracy better than ±0.01 nm with much relaxed requirement on temperature stability of the filter.

  5. High-accuracy mass determination of unstable cesium and barium isotopes

    CERN Document Server

    Ames, F; Beck, D; Bollen, G; De Saint-Simon, M; Jertz, R; Kluge, H J; Kohl, A; König, M; Lunney, M D; Martel, I; Moore, R B; Otto, T; Patyk, Z; Raimbault-Hartmann, H; Rouleau, G; Savard, G; Schark, E; Schwarz, S; Schweikhard, L; Stolzenberg, H; Szerypo, J

    1999-01-01

    Direct mass measurements of short-lived Cs and Ba isotopes have been performed with the tandem Penning trap mass spectrometer ISOLTRAP installed at the on-line isotope separator ISOLDE at CERN. Typically, a mass resolving power of 600 000 and an accuracy of $\\delta \\mbox{m} \\approx 13$ keV have been obtained. The masses of $^{123,124,126}$Ba and $^{122m}$Cs were measured for the first time. A least-squares adjustment has been performed and the experimental masses are compared with theoretical ones, particularly in the frame of a macroscopic-microscopic model.

  6. High-accuracy mass determination of neutron-rich rubidium and strontiumiIsotopes

    CERN Document Server

    Raimbault-Hartmann, H; Beck, D; Bollen, G; De Saint-Simon, M; Kluge, H J; König, M; Moore, R B; Schwarz, S; Savard, G; Szerypo, J

    2002-01-01

    The penning-trap mass spectrometer ISOLTRAP, installed at the on-line isotope separator ISOLDE at CERN, has been used to measure atomic masses of $^{88,89,90m,91,92,93,94}$Rb and $^{91- 95}$Sr. Using a resolving power of R $\\!\\scriptstyle\\approx$1 million a mass accuracy of typically 10 keV was achieved for all nuclides. Discrepancies with older data are analyzed and discussed, leading to corrections to those data. Together with the present ISOLTRAP data these corrected data have been used in the general mass adjustment.

  7. High-Accuracy Measurements of the Centre of Gravity of Avalanches in Proportional Chambers

    Science.gov (United States)

    Charpak, G.; Jeavons, A.; Sauli, F.; Stubbs, R.

    1973-09-24

    In a multiwire proportional chamber the avalanches occur close to the anode wires. The motion of the positive ions in the large electric fields at the vicinity of the wires induces fast-rising positive pulses on the surrounding electrodes. Different methods have been developed in order to determine the position of the centre of the avalanches. In the method we describe, the centre of gravity of the pulse distribution is measured directly. It seems to lead to an accuracy which is limited only by the stability of the spatial distribution of the avalanches generated by the process being measured.

  8. High-Accuracy Tracking Control of Robot Manipulators Using Time Delay Estimation and Terminal Sliding Mode

    Directory of Open Access Journals (Sweden)

    Maolin Jin

    2011-09-01

    Full Text Available A time delay estimation based general framework for trajectory tracking control of robot manipulators is presented. The controller consists of three elements: a time‐delay‐estimation element that cancels continuous nonlinearities of robot dynamics, an injecting element that endows desired error dynamics, and a correcting element that suppresses residual time delay estimation error caused by discontinuous nonlinearities. Terminal sliding mode is used for the correcting element to pursue fast convergence of the time delay estimation error. Implementation of proposed control is easy because calculation of robot dynamics including friction is not required. Experimental results verify high‐accuracy trajectory tracking of industrial robot manipulators.

  9. High-Accuracy Tracking Using Ultrawideband Signals for Enhanced Safety of Cyclists

    Directory of Open Access Journals (Sweden)

    Davide Dardari

    2017-01-01

    Full Text Available In this paper, an ultrawideband localization system to improve the cyclists’ safety is presented. The architectural solutions proposed consist of tags placed on bikes, whose positions have to be estimated, and anchors, acting as reference nodes, located at intersections and/or on vehicles. The peculiarities of the localization system in terms of accuracy and cost enable its adoption with enhanced risk assessment units situated on the infrastructure/vehicle, depending on the architecture chosen, as well as real-time warning to the road users. Experimental results reveal that the localization error, in both static and dynamic conditions, is below 50 cm in most of the cases.

  10. Affine-Invariant Geometric Constraints-Based High Accuracy Simultaneous Localization and Mapping

    Directory of Open Access Journals (Sweden)

    Gangchen Hua

    2017-01-01

    Full Text Available In this study we describe a new appearance-based loop-closure detection method for online incremental simultaneous localization and mapping (SLAM using affine-invariant-based geometric constraints. Unlike other pure bag-of-words-based approaches, our proposed method uses geometric constraints as a supplement to improve accuracy. By establishing an affine-invariant hypothesis, the proposed method excludes incorrect visual words and calculates the dispersion of correctly matched visual words to improve the accuracy of the likelihood calculation. In addition, camera’s intrinsic parameters and distortion coefficients are adequate for this method. 3D measuring is not necessary. We use the mechanism of Long-Term Memory and Working Memory (WM to manage the memory. Only a limited size of the WM is used for loop-closure detection; therefore the proposed method is suitable for large-scale real-time SLAM. We tested our method using the CityCenter and Lip6Indoor datasets. Our proposed method results can effectively correct the typical false-positive localization of previous methods, thus gaining better recall ratios and better precision.

  11. High-accuracy 3-D modeling of cultural heritage: the digitizing of Donatello's "Maddalena".

    Science.gov (United States)

    Guidi, Gabriele; Beraldin, J Angelo; Atzeni, Carlo

    2004-03-01

    Three-dimensional digital modeling of Heritage works of art through optical scanners, has been demonstrated in recent years with results of exceptional interest. However, the routine application of three-dimensional (3-D) modeling to Heritage conservation still requires the systematic investigation of a number of technical problems. In this paper, the acquisition process of the 3-D digital model of the Maddalena by Donatello, a wooden statue representing one of the major masterpieces of the Italian Renaissance which was swept away by the Florence flood of 1966 and successively restored, is described. The paper reports all the steps of the acquisition procedure, from the project planning to the solution of the various problems due to range camera calibration and to material non optically cooperative. Since the scientific focus is centered on the 3-D model overall dimensional accuracy, a methodology for its quality control is described. Such control has demonstrated how, in some situations, the ICP-based alignment can lead to incorrect results. To circumvent this difficulty we propose an alignment technique based on the fusion of ICP with close-range digital photogrammetry and a non-invasive procedure in order to generate a final accurate model. In the end detailed results are presented, demonstrating the improvement of the final model, and how the proposed sensor fusion ensure a pre-specified level of accuracy.

  12. Axis-Exchanged Compensation and Gait Parameters Analysis for High Accuracy Indoor Pedestrian Dead Reckoning

    Directory of Open Access Journals (Sweden)

    Honghui Zhang

    2015-01-01

    Full Text Available Pedestrian dead reckoning (PDR is an effective way for navigation coupled with GNSS (Global Navigation Satellite System or weak GNSS signal environment like indoor scenario. However, indoor location with an accuracy of 1 to 2 meters determined by PDR based on MEMS-IMU is still very challenging. For one thing, heading estimation is an important problem in PDR because of the singularities. For another thing, walking distance estimation is also a critical problem for pedestrian walking with randomness. Based on the above two problems, this paper proposed axis-exchanged compensation and gait parameters analysis algorithm to improve the navigation accuracy. In detail, an axis-exchanged compensation factored quaternion algorithm is put forward first to overcome the singularities in heading estimation without increasing the amount of computation. Besides, real-time heading is updated by R-adaptive Kalman filter. Moreover, gait parameters analysis algorithm can be divided into two steps: cadence detection and step length estimation. Thus, a method of cadence classification and interval symmetry is proposed to detect the cadence accurately. Furthermore, a step length model adjusted by cadence is established for step length estimation. Compared to the traditional PDR navigation, experimental results showed that the error of navigation reduces 32.6%.

  13. High accuracy microwave frequency measurement based on single-drive dual-parallel Mach-Zehnder modulator

    DEFF Research Database (Denmark)

    Zhao, Ying; Pang, Xiaodan; Deng, Lei

    2011-01-01

    A novel approach for broadband microwave frequency measurement by employing a single-drive dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. Based on bias manipulations of the modulator, conventional frequency-to-power mapping technique is developed by performing a...... 10−3 relative error. This high accuracy frequency measurement technique is a promising candidate for high-speed electronic warfare and defense applications.......A novel approach for broadband microwave frequency measurement by employing a single-drive dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. Based on bias manipulations of the modulator, conventional frequency-to-power mapping technique is developed by performing...... a two-stage frequency measurement cooperating with digital signal processing. In the experiment, 10GHz measurement range is guaranteed and the average uncertainty of estimated microwave frequency is 5.4MHz, which verifies the measurement accuracy is significantly improved by achieving an unprecedented...

  14. Brief Report: Face Configuration Accuracy and Processing Speed Among Adults with High-Functioning Autism Spectrum Disorders

    OpenAIRE

    Faja, Susan; Webb, Sara Jane; Merkle, Kristen; Aylward, Elizabeth; Dawson, Geraldine

    2008-01-01

    The present study investigates the accuracy and speed of face processing employed by high-functioning adults with autism spectrum disorders (ASDs). Two behavioral experiments measured sensitivity to distances between features and face recognition when performance depended on holistic versus featural information. Results suggest adults with ASD were less accurate, but responded as quickly as controls for both tasks. In contrast to previous findings with children, adults with ASD demonstrated a...

  15. The Effect of Moderate and High-Intensity Fatigue on Groundstroke Accuracy in Expert and Non-Expert Tennis Players

    OpenAIRE

    Mark Lyons; Yahya Al-Nakeeb; Joanne Hankey; Alan Nevill

    2013-01-01

    peer-reviewed Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player's achievement motivation characteristics. 13 expert (7 male, 6 female) and 17 non-expe...

  16. A High Accuracy Pedestrian Detection System Combining a Cascade AdaBoost Detector and Random Vector Functional-Link Net

    OpenAIRE

    Zhihui Wang; Sook Yoon; Shan Juan Xie; Yu Lu; Dong Sun Park

    2014-01-01

    In pedestrian detection methods, their high accuracy detection rates are always obtained at the cost of a large amount of false pedestrians. In order to overcome this problem, the authors propose an accurate pedestrian detection system based on two machine learning methods: cascade AdaBoost detector and random vector functional-link net. During the offline training phase, the parameters of a cascade AdaBoost detector and random vector functional-link net are trained by standard dataset. These...

  17. Towards a magnetic field stabilization at ISOLTRAP for high-accuracy mass measurements on exotic nuclides

    CERN Document Server

    Marie-Jeanne, M; Blaum, K; Djekic, S; Dworschak, M; Hager, U; Herlert, A; Nagy, S; Savreux, R; Schweikhard, L; Stahl, S; Yazidjian, C

    2008-01-01

    The field stability of a mass spectrometer plays a crucial role in the accuracy of mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of fluctuations are temperature variations in the vicinity of the trap and pressure changes in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the temperature and pressure fluctuations by at least an order of magnitude down to and has been achieved, which corresponds to a relative magnetic field change of ΔB/B=2.7×10-9 and 1.1×10-10, respectively.

  18. High accuracy calculation of the hydrogen negative ion in strong magnetic fields

    Institute of Scientific and Technical Information of China (English)

    Zhao Ji-Jun; Wang Xiao-Feng; Qiao Hao-Xue

    2011-01-01

    Using a full configuration-interaction method with Hylleraas-Gaussian basis function, this paper investigates the 110+, 11(-1)+ and l1(-2)+ states of the hydrogen negative ion in strong magnetic fields. The total energies, electron detachment energies and derivatives of the total energy with respect to the magnetic field are presented as functions of magnetic field over a wide range of field strengths. Compared with the available theoretical data, the accuracy for the energies is enhanced significantly. The field regimes 3 <γ< 4 and 0.02 < 7< 0.05, in which the l1(-l)+ and l1(-2)+states start to become bound, respectively, are also determined based on the calculated electron detachment energies.

  19. Hyperbolic Method for Dispersive PDEs: Same High-Order of Accuracy for Solution, Gradient, and Hessian

    Science.gov (United States)

    Mazaheri, Alireza; Ricchiuto, Mario; Nishikawa, Hiroaki

    2016-01-01

    In this paper, we introduce a new hyperbolic first-order system for general dispersive partial differential equations (PDEs). We then extend the proposed system to general advection-diffusion-dispersion PDEs. We apply the fourth-order RD scheme of Ref. 1 to the proposed hyperbolic system, and solve time-dependent dispersive equations, including the classical two-soliton KdV and a dispersive shock case. We demonstrate that the predicted results, including the gradient and Hessian (second derivative), are in a very good agreement with the exact solutions. We then show that the RD scheme applied to the proposed system accurately captures dispersive shocks without numerical oscillations. We also verify that the solution, gradient and Hessian are predicted with equal order of accuracy.

  20. A Scoring Tool to Identify East African HIV-1 Serodiscordant Partnerships with a High Likelihood of Pregnancy.

    Directory of Open Access Journals (Sweden)

    Renee Heffron

    Full Text Available HIV-1 prevention programs targeting HIV-1 serodiscordant couples need to identify couples that are likely to become pregnant to facilitate discussions about methods to minimize HIV-1 risk during pregnancy attempts (i.e. safer conception or effective contraception when pregnancy is unintended. A clinical prediction tool could be used to identify HIV-1 serodiscordant couples with a high likelihood of pregnancy within one year.Using standardized clinical prediction methods, we developed and validated a tool to identify heterosexual East African HIV-1 serodiscordant couples with an increased likelihood of becoming pregnant in the next year. Datasets were from three prospectively followed cohorts, including nearly 7,000 couples from Kenya and Uganda participating in HIV-1 prevention trials and delivery projects.The final score encompassed the age of the woman, woman's number of children living, partnership duration, having had condomless sex in the past month, and non-use of an effective contraceptive. The area under the curve (AUC for the probability of the score to correctly predict pregnancy was 0.74 (95% CI 0.72-0.76. Scores ≥ 7 predicted a pregnancy incidence of >17% per year and captured 78% of the pregnancies. Internal and external validation confirmed the predictive ability of the score.A pregnancy likelihood score encompassing basic demographic, clinical and behavioral factors defined African HIV-1 serodiscordant couples with high one-year pregnancy incidence rates. This tool could be used to engage African HIV-1 serodiscordant couples in counseling discussions about fertility intentions in order to offer services for safer conception or contraception that align with their reproductive goals.

  1. Evaluation of Heart Rate Assessment Timing, Communication, Accuracy, and Clinical Decision-Making during High Fidelity Simulation of Neonatal Resuscitation

    Directory of Open Access Journals (Sweden)

    Win Boon

    2014-01-01

    Full Text Available Objective. Accurate heart rate (HR determination during neonatal resuscitation (NR informs subsequent NR actions. This study’s objective was to evaluate HR determination timeliness, communication, and accuracy during high fidelity NR simulations that house officers completed during neonatal intensive care unit (NICU rotations. Methods. In 2010, house officers in NICU rotations completed high fidelity NR simulation. We reviewed 80 house officers’ videotaped performance on their initial high fidelity simulation session, prior to training and performance debriefing. We calculated the proportion of cases congruent with NR guidelines, using chi square analysis to evaluate performance across HR ranges relevant to NR decision-making: <60, 60–99, and ≥100 beats per minute (bpm. Results. 87% used umbilical cord palpation, 57% initiated HR assessment within 30 seconds, 70% were accurate, and 74% were communicated appropriately. HR determination accuracy varied significantly across HR ranges, with 87%, 57%, and 68% for HR <60, 60–99, and ≥100 bpm, respectively (P<0.001. Conclusions. Timeliness, communication, and accuracy of house officers’ HR determination are suboptimal, particularly for HR 60–100 bpm, which might lead to inappropriate decision-making and NR care. Training implications include emphasizing more accurate HR determination methods, better communication, and improved HR interpretation during NR.

  2. Prediction of Outcome After Emergency High-Risk Intra-abdominal Surgery Using the Surgical Apgar Score

    DEFF Research Database (Denmark)

    Cihoric, Mirjana; Toft Tengberg, Line; Bay-Nielsen, Morten

    2016-01-01

    BACKGROUND: With current literature quoting mortality rates up to 45%, emergency high-risk abdominal surgery has, compared with elective surgery, a significantly greater risk of death and major complications. The Surgical Apgar Score (SAS) is predictive of outcome in elective surgery, but has never...... been validated exclusively in an emergency setting. METHODS: A consecutive prospective single-center cohort study of 355 adults undergoing emergency high-risk abdominal surgery between June 2013 and May 2014 is presented. The primary outcome measure was 30-day mortality. Secondary outcome measures were...... the incidence of both outcomes. Area under the curve was used to demonstrate the scores' discriminatory power. RESULTS: One hundred eighty-one (51.0%) patients developed minor or no complications. The overall incidence of major complications was 32.7% and the overall death rate was 16.3%. Risk of major...

  3. Advanced Taste Sensors Based on Artificial Lipids with Global Selectivity to Basic Taste Qualities and High Correlation to Sensory Scores

    Directory of Open Access Journals (Sweden)

    Yoshikazu Kobayashi

    2010-04-01

    Full Text Available Effective R&D and strict quality control of a broad range of foods, beverages, and pharmaceutical products require objective taste evaluation. Advanced taste sensors using artificial-lipid membranes have been developed based on concepts of global selectivity and high correlation with human sensory score. These sensors respond similarly to similar basic tastes, which they quantify with high correlations to sensory score. Using these unique properties, these sensors can quantify the basic tastes of saltiness, sourness, bitterness, umami, astringency and richness without multivariate analysis or artificial neural networks. This review describes all aspects of these taste sensors based on artificial lipid, ranging from the response principle and optimal design methods to applications in the food, beverage, and pharmaceutical markets.

  4. Agreement between the SCORE and D’Agostino Scales for the Classification of High Cardiovascular Risk in Sedentary Spanish Patients

    Directory of Open Access Journals (Sweden)

    Luis García-Ortiz

    2009-11-01

    Full Text Available Background: To evaluate agreement between cardiovascular risk in sedentary patients as estimated by the new Framingham-D’Agostino scale and by the SCORE chart, and to describe the patient characteristics associated with the observed disagreement between the scales. Design: A cross-sectional study was undertaken involving a systematic sample of 2,295 sedentary individuals between 40–65 years of age seen for any reason in 56 primary care offices. An estimation was made of the Pearson correlation coefficient and kappa statistic for the classification of high risk subjects (≥20% according to the Framingham-D’Agostino scale, and ≥5% according to SCORE. Polytomous logistic regression models were fitted to identify the variables associated with the discordance between the two scales. Results: The mean risk in males (35% was 19.5% ± 13% with D’Agostino scale, and 3.2% ± 3.3% with SCORE. Among females, they were 8.1% ± 6.8% and 1.2% ± 2.2%, respectively. The correlation between the two scales was 0.874 in males (95% CI: 0.857–0.889 and 0.818 in females (95% CI: 0.800–0.834, while the kappa index was 0.50 in males (95% CI: 0.44%–0.56% and 0.61 in females (95% CI: 0.52%–0.71%. The most frequent disagreement, characterized by high risk according to D’Agostino scale but not according to SCORE, was much more prevalent among males and proved more probable with increasing age and increased LDL-cholesterol, triglyceride and systolic blood pressure values, as well as among those who used antihypertensive drugs and smokers. Conclusions: The quantitative correlation between the two scales is very high. Patient categorization as corresponding to high risk generates disagreements, mainly among males, where agreement between the two classifications is only moderate.

  5. High-accuracy CFD prediction methods for fluid and structure temperature fluctuations at T-junction for thermal fatigue evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Shaoxiang, E-mail: qian.shaoxiang@jgc.com [EN Technology Center, Process Technology Division, JGC Corporation, 2-3-1 Minato Mirai, Nishi-ku, Yokohama 220-6001 (Japan); Kanamaru, Shinichiro [EN Technology Center, Process Technology Division, JGC Corporation, 2-3-1 Minato Mirai, Nishi-ku, Yokohama 220-6001 (Japan); Kasahara, Naoto [Nuclear Engineering and Management, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2015-07-15

    Highlights: • Numerical methods for accurate prediction of thermal loading were proposed. • Predicted fluid temperature fluctuation (FTF) intensity is close to the experiment. • Predicted structure temperature fluctuation (STF) range is close to the experiment. • Predicted peak frequencies of FTF and STF also agree well with the experiment. • CFD results show the proposed numerical methods are of sufficiently high accuracy. - Abstract: Temperature fluctuations generated by the mixing of hot and cold fluids at a T-junction, which is widely used in nuclear power and process plants, can cause thermal fatigue failure. The conventional methods for evaluating thermal fatigue tend to provide insufficient accuracy, because they were developed based on limited experimental data and a simplified one-dimensional finite element analysis (FEA). CFD/FEA coupling analysis is expected as a useful tool for the more accurate evaluation of thermal fatigue. The present paper aims to verify the accuracy of proposed numerical methods of simulating fluid and structure temperature fluctuations at a T-junction for thermal fatigue evaluation. The dynamic Smagorinsky model (DSM) is used for large eddy simulation (LES) sub-grid scale (SGS) turbulence model, and a hybrid scheme (HS) is adopted for the calculation of convective terms in the governing equations. Also, heat transfer between fluid and structure is calculated directly through thermal conduction by creating a mesh with near wall resolution (NWR) by allocating grid points within the thermal boundary sub-layer. The simulation results show that the distribution of fluid temperature fluctuation intensity and the range of structure temperature fluctuation are remarkably close to the experimental results. Moreover, the peak frequencies of power spectrum density (PSD) of both fluid and structure temperature fluctuations also agree well with the experimental results. Therefore, the numerical methods used in the present paper are

  6. Radiometric inter-sensor cross-calibration uncertainty using a traceable high accuracy reference hyperspectral imager

    Science.gov (United States)

    Gorroño, Javier; Banks, Andrew C.; Fox, Nigel P.; Underwood, Craig

    2017-08-01

    Optical earth observation (EO) satellite sensors generally suffer from drifts and biases relative to their pre-launch calibration, caused by launch and/or time in the space environment. This places a severe limitation on the fundamental reliability and accuracy that can be assigned to satellite derived information, and is particularly critical for long time base studies for climate change and enabling interoperability and Analysis Ready Data. The proposed TRUTHS (Traceable Radiometry Underpinning Terrestrial and Helio-Studies) mission is explicitly designed to address this issue through re-calibrating itself directly to a primary standard of the international system of units (SI) in-orbit and then through the extension of this SI-traceability to other sensors through in-flight cross-calibration using a selection of Committee on Earth Observation Satellites (CEOS) recommended test sites. Where the characteristics of the sensor under test allows, this will result in a significant improvement in accuracy. This paper describes a set of tools, algorithms and methodologies that have been developed and used in order to estimate the radiometric uncertainty achievable for an indicative target sensor through in-flight cross-calibration using a well-calibrated hyperspectral SI-traceable reference sensor with observational characteristics such as TRUTHS. In this study, Multi-Spectral Imager (MSI) of Sentinel-2 and Landsat-8 Operational Land Imager (OLI) is evaluated as an example, however the analysis is readily translatable to larger-footprint sensors such as Sentinel-3 Ocean and Land Colour Instrument (OLCI) and Visible Infrared Imaging Radiometer Suite (VIIRS). This study considers the criticality of the instrumental and observational characteristics on pixel level reflectance factors, within a defined spatial region of interest (ROI) within the target site. It quantifies the main uncertainty contributors in the spectral, spatial, and temporal domains. The resultant tool

  7. Adaptive switching frequency buck DC—DC converter with high-accuracy on-chip current sensor

    Science.gov (United States)

    Jinguang, Jiang; Fei, Huang; Zhihui, Xiong

    2015-05-01

    A current-mode PWM buck DC—DC converter is proposed. With the high-accuracy on-chip current sensor, the switching frequency can be selected automatically according to load requirements. This method improves efficiency and obtains an excellent transient response. The high accuracy of the current sensor is achieved by a simple switch technique without an amplifier. This has the direct benefit of reducing power dissipation and die size. Additionally, a novel soft-start circuit is presented to avoid the inrush current at the starting up state. Finally, this DC—DC converter is fabricated with the 0.5 μm standard CMOS process. The chip occupies 3.38 mm2. The accuracy of the proposed current sensor can achieve 99.5% @ 200 mA. Experimental results show that the peak efficiency is 91.8%. The input voltage ranges from 5 to 18 V, while a 2 A load current can be obtained. Project supported by the National Natural Science Foundation of China (No. 41274047), the Natural Science Foundation of Jiangsu Province (No. BK2012639), the Science and Technology Enterprises in Jiangsu Province Technology Innovation Fund (No. BC2012121), and the Changzhou Science and Technology Support (Industrial) Project (No. CE20120074).

  8. Reduced leptin level is independently of fat mass changes and hunger scores from high-intensity intermittent plus strength training.

    Science.gov (United States)

    Inoue, Daniela S; Gonçalves Panissa, Valéria L; Mello Antunes, Barbara; Poleto de Oliveira, Flaviane; Bernardes Malta, Raoni; Santos Caldeira, Renan; Zapaterra Campos, Eduardo; Duarte Pimentel, Gustavo; Franchini, Emerson; Santos Lira, Fábio

    2017-05-09

    This study aimed to analyze the effects of high-intensity intermittent training (HIIT) plus strength training on body composition, hormone related to energetic balance (leptin), and hunger scores in physically active non-obese men. Sixteen men were allocated in two different groups, training group (n=10) performed a combined HIIT (5 km, 1 min of effort interspersed by 1 min of rest in passive recovery) followed by strength exercise session (three sets, with load of 8-12 repetition maximum) twice a week, during 8 weeks, while control group (n=6) did not suffer any intervention. Hunger scores, leptin concentrations and body composition were assessed. Body composition, fasting leptin and hunger score were compared through two-way analysis (group and period) with repeated measures in the second factor while leptin and hunger scores in exercise session pre- and post-8weeks through two-way analysis (period and time of measurement) with repeated measures in the second factor. The fasting leptin decreased pre- to post-8week in training group (7.7 ± 4.9 to 2.9 ± 2.1 ng/ml; p = 0.012). For leptin response to exercise session there was main effect of training period, with higher values pre- (6.5 ± 3.9 ng/ml) than post-training (2.6 ± 2.1 ng/ml; p < 0.001). For hunger scores there was effect of time of measurement (p <0.001), decreasing after breakfast and increasing over the experiment. Combined HIIT plus strength training were able to promote alterations in a hormone related to energy balance independent of body composition and hunger index alterations in physically active non-obese men.

  9. Repeated High-Intensity Effort Activity in Relation to Tries Scored and Conceded during Rugby League Match-Play.

    Science.gov (United States)

    Gabbett, Tim J; Gahan, Caleb W

    2015-09-21

    To examine the nature and frequency of rugby league repeated high-intensity effort (RHIE) activity in relation to tries scored and conceded in successful and unsuccessful teams. One-hundred and eighty-five semi-professional rugby league players (mean ± SD age: 23.7 ± 3.2 yr) from 11 teams participated in this study. Global positioning system (GPS) data was collected during 21 matches. Data were analysed for the total number of RHIE bouts, efforts per bout, duration of efforts and recovery between efforts. Using notational analysis, a RHIE bout frequency distribution, representing 0-60s, 61-120s, 121-180s, 181-240s, and 241-300s prior to scoring and conceding a try was established. Over 50% of RHIE bouts occurred within five minutes of a try. Bottom 4 teams performed a greater proportion of bouts within five minutes of a try than Top 4 teams (61.5% vs. 48.2%, effect size, ES = 0.69 ± 0.28, p=0.0001). Top 4 teams performed a greater number of RHIE bouts per conceded try (3.0 ± 2.1 vs. 1.6 ± 0.7, ES = 0.74 ± 0.51, pteams performed a greater number of RHIE bouts per try scored (3.6 ± 2.5 vs. 2.1 ± 1.7, ES = 0.70 ± 0.71, p=0.10). The majority of rugby league RHIE bouts occur at critical periods during match-play. Successful rugby league teams perform more RHIE bouts prior to conceding tries, while unsuccessful teams perform more bouts prior to scoring tries. These findings demonstrate that unsuccessful teams are required to work harder to score tries while successful teams work harder to prevent tries.

  10. TGF-β1 in bronchoalveolar lavage fluid in diffuse parenchymal lung diseases and high-resolution computed tomography score

    Directory of Open Access Journals (Sweden)

    Artur Szlubowski

    2010-07-01

    Full Text Available INTRODUCTION: In the pathogenesis of diffuse parenchymal lung diseases (DPLDs, growth factors, including transforming growth factor β1 (TGF-β1, are responsible for cell proliferation, apoptosis, chemotaxis, and angiogenesis, and also for the production and secretion of some components of the extracellular matrix. OBJECTIVES: The aim of the study was to evaluate correlations in DPLDs between TGF-β1 levels in bronchoalveolar lavage (BAL fluid and high-resolution computed tomography (HRCT score. PATIENTS AND METHODS: The study was performed in 31 DPLD patients in whom a selection of lung segments with high and low intensity of abnormalities was estimated by HRCT score. All patients underwent BAL with TGF-β1 measured by an enzyme immunoassay in BAL fluid and video-assisted thoracic surgery lung biopsy from both selected segments. RESULTS: All 31 patients were diagnosed, and based on histopathology, they were classified into 2 groups: idiopathic interstitial pneumonia (usual interstitial pneumonia – 12, nonspecific interstitialpneumonia – 2, cryptogenic organizing pneumonia – 2, and desquamative interstitial pneumonia – 1 and granulomatous disease (sarcoidosis – 7, extrinsic allergic alveolitis – 5, and histiocytosis X – 2. The final analysis was performed in 28 patients who showed nonhomogenous distribution on HRCT. TGF-β1 levels in BAL fluid were significantly higher in the areas with high intensity of abnormalities assessed by HRCT score (P = 0.018, analysis of variance. These levels were not different between the groups, but a trend towards higher levels in idiopathic interstitial pneumonia was observed. CONCLUSIONS: The results confirm that TGF-β1 may be a good but not specific marker of fibrosis in DPLDs. A significant positive correlation between TGF-β1 levels in BAL fluid and the HRCT score was observed.

  11. Convergence of Sample Eigenvalues, Eigenvectors, and Principal Component Scores for Ultra-High Dimensional Data.

    Science.gov (United States)

    Lee, Seunggeun; Zou, Fei; Wright, Fred A

    2014-06-01

    The development of high-throughput biomedical technologies has led to increased interest in the analysis of high-dimensional data where the number of features is much larger than the sample size. In this paper, we investigate principal component analysis under the ultra-high dimensional regime, where both the number of features and the sample size increase as the ratio of the two quantities also increases. We bridge the existing results from the finite and the high-dimension low sample size regimes, embedding the two regimes in a more general framework. We also numerically demonstrate the universal application of the results from the finite regime.

  12. High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Shaohui Foong

    2016-08-01

    Full Text Available In this paper, a novel magnetic field-based sensing system employing statistically optimized concurrent multiple sensor outputs for precise field-position association and localization is presented. This method capitalizes on the independence between simultaneous spatial field measurements at multiple locations to induce unique correspondences between field and position. This single-source-multi-sensor configuration is able to achieve accurate and precise localization and tracking of translational motion without contact over large travel distances for feedback control. Principal component analysis (PCA is used as a pseudo-linear filter to optimally reduce the dimensions of the multi-sensor output space for computationally efficient field-position mapping with artificial neural networks (ANNs. Numerical simulations are employed to investigate the effects of geometric parameters and Gaussian noise corruption on PCA assisted ANN mapping performance. Using a 9-sensor network, the sensing accuracy and closed-loop tracking performance of the proposed optimal field-based sensing system is experimentally evaluated on a linear actuator with a significantly more expensive optical encoder as a comparison.

  13. High-resolution CT of transplanted teeth: imaging technique and measurement accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Gahleitner, Andre [Medical University of Vienna, Department of Radiology/Osteology and MR, Vienna (Austria); Medical University Vienna, Department of Radiology, Vienna (Austria); Kuchler, Ulrike; Heschl, Janina; Watzek, Georg [Medical University of Vienna, Department of Oral Surgery, Vienna (Austria); Homolka, Peter [Medical University of Vienna, Center for Biomedical Engineering and Physics, Vienna (Austria); Imhof, Herwig [Medical University of Vienna, Department of Radiology/Osteology and MR, Vienna (Austria)

    2008-12-15

    The aim of this study was to determine the accuracy of crown diameter measurements by dental CT as a tool for preoperative diagnosis before tooth transplantations. Fifty-eight patients underwent clinically indicated dental CT. The diameter of the crowns were measured by CT using a standard protocol (1.5-mm slice thickness, 1-mm table feed, 120 kV, 25-75 mA/s, 2-s scan time/slice, 512 matrix) and a standard dental software package. Postoperatively, the same distances were clinically measured using a sliding gauge. The degree of the deviation between CT measurements and clinical measurements was in the sub-millimeter range. According to the regression analysis, the correlation coefficient equals 0.98 and 0.97, indicating a strong relationship between the CT and the manual measurement of the crown diameter in the bucco-lingual and the mesio-distal direction. The mean deviation of CT measurements with regard to the bucco-lingual diameter of the crown was +0.08 mm (SD: {+-}0.38 mm). For the mesio-distal diameter, the mean deviation of CT measurements was -0.24 mm (SD: {+-}0.53 mm). These results demonstrate that dental CT promises to be a valuable tool for the evaluation of the potential and optimal size and site for tooth transplantations. (orig.)

  14. Novel speech signal processing algorithms for high-accuracy classification of Parkinson's disease.

    Science.gov (United States)

    Tsanas, Athanasios; Little, Max A; McSharry, Patrick E; Spielman, Jennifer; Ramig, Lorraine O

    2012-05-01

    There has been considerable recent research into the connection between Parkinson's disease (PD) and speech impairment. Recently, a wide range of speech signal processing algorithms (dysphonia measures) aiming to predict PD symptom severity using speech signals have been introduced. In this paper, we test how accurately these novel algorithms can be used to discriminate PD subjects from healthy controls. In total, we compute 132 dysphonia measures from sustained vowels. Then, we select four parsimonious subsets of these dysphonia measures using four feature selection algorithms, and map these feature subsets to a binary classification response using two statistical classifiers: random forests and support vector machines. We use an existing database consisting of 263 samples from 43 subjects, and demonstrate that these new dysphonia measures can outperform state-of-the-art results, reaching almost 99% overall classification accuracy using only ten dysphonia features. We find that some of the recently proposed dysphonia measures complement existing algorithms in maximizing the ability of the classifiers to discriminate healthy controls from PD subjects. We see these results as an important step toward noninvasive diagnostic decision support in PD.

  15. High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis

    Science.gov (United States)

    Foong, Shaohui; Sun, Zhenglong

    2016-01-01

    In this paper, a novel magnetic field-based sensing system employing statistically optimized concurrent multiple sensor outputs for precise field-position association and localization is presented. This method capitalizes on the independence between simultaneous spatial field measurements at multiple locations to induce unique correspondences between field and position. This single-source-multi-sensor configuration is able to achieve accurate and precise localization and tracking of translational motion without contact over large travel distances for feedback control. Principal component analysis (PCA) is used as a pseudo-linear filter to optimally reduce the dimensions of the multi-sensor output space for computationally efficient field-position mapping with artificial neural networks (ANNs). Numerical simulations are employed to investigate the effects of geometric parameters and Gaussian noise corruption on PCA assisted ANN mapping performance. Using a 9-sensor network, the sensing accuracy and closed-loop tracking performance of the proposed optimal field-based sensing system is experimentally evaluated on a linear actuator with a significantly more expensive optical encoder as a comparison. PMID:27529253

  16. Designing a high accuracy 3D auto stereoscopic eye tracking display, using a common LCD monitor

    Science.gov (United States)

    Taherkhani, Reza; Kia, Mohammad

    2012-09-01

    This paper describes the design and building of a low cost and practical stereoscopic display that does not need to wear special glasses, and uses eye tracking to give a large degree of freedom to viewer (or viewer's) movement while displaying the minimum amount of information. The parallax barrier technique is employed to turn a LCD into an auto-stereoscopic display. The stereo image pair is screened on the usual liquid crystal display simultaneously but in different columns of pixels. Controlling of the display in red-green-blue sub pixels increases the accuracy of light projecting direction to less than 2 degrees without losing too much LCD's resolution and an eye-tracking system determines the correct angle to project the images along the viewer's eye pupils and an image processing system puts the 3D images data in correct R-G-B sub pixels. 1.6 degree of light direction controlling achieved in practice. The 3D monitor is just made by applying some simple optical materials on a usual LCD display with normal resolution. [Figure not available: see fulltext.

  17. High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis.

    Science.gov (United States)

    Foong, Shaohui; Sun, Zhenglong

    2016-08-12

    In this paper, a novel magnetic field-based sensing system employing statistically optimized concurrent multiple sensor outputs for precise field-position association and localization is presented. This method capitalizes on the independence between simultaneous spatial field measurements at multiple locations to induce unique correspondences between field and position. This single-source-multi-sensor configuration is able to achieve accurate and precise localization and tracking of translational motion without contact over large travel distances for feedback control. Principal component analysis (PCA) is used as a pseudo-linear filter to optimally reduce the dimensions of the multi-sensor output space for computationally efficient field-position mapping with artificial neural networks (ANNs). Numerical simulations are employed to investigate the effects of geometric parameters and Gaussian noise corruption on PCA assisted ANN mapping performance. Using a 9-sensor network, the sensing accuracy and closed-loop tracking performance of the proposed optimal field-based sensing system is experimentally evaluated on a linear actuator with a significantly more expensive optical encoder as a comparison.

  18. Apgar score

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003402.htm Apgar score To use the sharing features on this page, ... birth. Virginia Apgar, MD (1909-1974) introduced the Apgar score in 1952. How the Test is Performed The ...

  19. Forecasting the value of credit scoring

    Science.gov (United States)

    Saad, Shakila; Ahmad, Noryati; Jaffar, Maheran Mohd

    2017-08-01

    Nowadays, credit scoring system plays an important role in banking sector. This process is important in assessing the creditworthiness of customers requesting credit from banks or other financial institutions. Usually, the credit scoring is used when customers send the application for credit facilities. Based on the score from credit scoring, bank will be able to segregate the "good" clients from "bad" clients. However, in most cases the score is useful at that specific time only and cannot be used to forecast the credit worthiness of the same applicant after that. Hence, bank will not know if "good" clients will always be good all the time or "bad" clients may become "good" clients after certain time. To fill up the gap, this study proposes an equation to forecast the credit scoring of the potential borrowers at a certain time by using the historical score related to the assumption. The Mean Absolute Percentage Error (MAPE) is used to measure the accuracy of the forecast scoring. Result shows the forecast scoring is highly accurate as compared to actual credit scoring.

  20. ISPA - a high accuracy X-ray and gamma camera Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    ISPA offers ... Ten times better resolution than Anger cameras High efficiency single gamma counting Noise reduction by sensitivity to gamma energy ...for Single Photon Emission Computed Tomography (SPECT)

  1. Expression of CRM1 and CDK5 shows high prognostic accuracy for gastric cancer

    Science.gov (United States)

    Sun, Yu-Qin; Xie, Jian-Wei; Xie, Hong-Teng; Chen, Peng-Chen; Zhang, Xiu-Li; Zheng, Chao-Hui; Li, Ping; Wang, Jia-Bin; Lin, Jian-Xian; Cao, Long-Long; Huang, Chang-Ming; Lin, Yao

    2017-01-01

    AIM To evaluate the predictive value of the expression of chromosomal maintenance (CRM)1 and cyclin-dependent kinase (CDK)5 in gastric cancer (GC) patients after gastrectomy. METHODS A total of 240 GC patients who received standard gastrectomy were enrolled in the study. The expression level of CRM1 and CDK5 was detected by immunohistochemistry. The correlations between CRM1 and CDK5 expression and clinicopathological factors were explored. Univariate and multivariate survival analyses were used to identify prognostic factors for GC. Receiver operating characteristic analysis was used to compare the accuracy of the prediction of clinical outcome by the parameters. RESULTS The expression of CRM1 was significantly related to size of primary tumor (P = 0.005), Borrmann type (P = 0.006), degree of differentiation (P = 0.004), depth of invasion (P = 0.008), lymph node metastasis (P = 0.013), TNM stage (P = 0.002) and distant metastasis (P = 0.015). The expression of CDK5 was significantly related to sex (P = 0.048) and Lauren’s classification (P = 0.011). Multivariate Cox regression analysis identified that CRM1 and CDK5 co-expression status was an independent prognostic factor for overall survival (OS) of patients with GC. Integration of CRM1 and CDK5 expression could provide additional prognostic value for OS compared with CRM1 or CDK5 expression alone (P = 0.001). CONCLUSION CRM1 and CDK5 co-expression was an independent prognostic factors for GC. Combined CRM1 and CDK5 expression could provide a prognostic model for OS of GC. PMID:28373767

  2. Influence of measuring algorithm on shape accuracy in the compensating turning of high gradient thin-wall parts

    Science.gov (United States)

    Wang, Tao; Wang, Guilin; Zhu, Dengchao; Li, Shengyi

    2015-02-01

    In order to meet the requirement of aerodynamics, the infrared domes or windows with conformal and thin-wall structure becomes the development trend of high-speed aircrafts in the future. But these parts usually have low stiffness, the cutting force will change along with the axial position, and it is very difficult to meet the requirement of shape accuracy by single machining. Therefore, on-machine measurement and compensating turning are used to control the shape errors caused by the fluctuation of cutting force and the change of stiffness. In this paper, on the basis of ultra precision diamond lathe, a contact measuring system with five DOFs is developed to achieve on-machine measurement of conformal thin-wall parts with high accuracy. According to high gradient surface, the optimizing algorithm is designed on the distribution of measuring points by using the data screening method. The influence rule of sampling frequency is analyzed on measuring errors, the best sampling frequency is found out based on planning algorithm, the effect of environmental factors and the fitting errors are controlled within lower range, and the measuring accuracy of conformal dome is greatly improved in the process of on-machine measurement. According to MgF2 conformal dome with high gradient, the compensating turning is implemented by using the designed on-machine measuring algorithm. The shape error is less than PV 0.8μm, greatly superior compared with PV 3μm before compensating turning, which verifies the correctness of measuring algorithm.

  3. High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Genovesi, Dario; Giorgetti, Assuero; Marzullo, Paolo [CNR, Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Bottai, Matteo [University of South Carolina, Division of Biostatistics, Columbia, SC (United States); Karolinska Institutet, Division of Biostatistics, Stockholm (Sweden); Di Martino, Fabio [AOUP, UO Fisica Sanitaria, Pisa (Italy)

    2012-01-15

    Appropriate use of SPECT imaging is regulated by evidence-based guidelines and appropriateness criteria in an effort to limit the burden of radiation administered to patients. We aimed at establishing whether the use of a low dose for stress-rest single-day nuclear myocardial perfusion imaging on an ultrafast (UF) cardiac gamma camera using cadmium-zinc-telluride solid-state detectors could be used routinely with the same accuracy obtained with standard doses and conventional cameras. To this purpose, 137 consecutive patients (mean age 61 {+-} 8 years) with known or suspected coronary artery disease (CAD) were enrolled. They underwent single-day low-dose stress-rest myocardial perfusion imaging using UF SPECT and invasive coronary angiography. Patients underwent the first scan with a 7-min acquisition time 10 min after the end of the stress protocol (dose range 185 to 222 MBq of {sup 99m}Tc-tetrofosmin). The rest scan (dose range 370 to 444 MBq of {sup 99m}Tc-tetrofosmin) was acquired with a 6-min acquisition time. The mean summed stress scores (SSS) and mean summed rest scores (SRS) were obtained semiquantitatively. Coronary angiograms showed significant epicardial CAD in 83% of patients. Mean SSS and SRS were 10 {+-} 5 and 3 {+-} 3, respectively. Overall the area under the ROC curve for the SSS values was 0.904, while the areas under the ROC curves for each vascular territory were 0.982 for the left anterior descending artery, 0.931 for the left circumflex artery and 0.889 for the right coronary artery. This pilot study demonstrated the feasibility of a low-dose single-day stress-rest fasting protocol performed using UF SPECT, with good sensitivity and specificity in detecting CAD at low patient exposure, opening new perspectives in the use of myocardial perfusion in ischaemic patients. (orig.)

  4. High-accuracy measurement of ship velocities by DGPS; DGPS ni yoru sensoku keisoku no koseidoka ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, S.; Koterayama, W. [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1996-04-10

    The differential global positioning system (DGPS) can eliminate most of errors in ship velocity measurement by GPS positioning alone. Through two rounds of marine observations by towing an observation robot in summer 1995, the authors attempted high-accuracy measurement of ship velocities by DGPS, and also carried out both positioning by GPS alone and measurement using the bottom track of ADCP (acoustic Doppler current profiler). In this paper, the results obtained by these measurement methods were examined through comparison among them, and the accuracy of the measured ship velocities was considered. In DGPS measurement, both translocation method and interference positioning method were used. ADCP mounted on the observation robot allowed measurement of the velocity of current meter itself by its bottom track in shallow sea areas less than 350m. As the result of these marine observations, it was confirmed that the accuracy equivalent to that of direct measurement by bottom track is possible to be obtained by DGPS. 3 refs., 5 figs., 1 tab.

  5. High-accuracy current generation in the nanoampere regime from a silicon single-trap electron pump

    Science.gov (United States)

    Yamahata, Gento; Giblin, Stephen P.; Kataoka, Masaya; Karasawa, Takeshi; Fujiwara, Akira

    2017-01-01

    A gigahertz single-electron (SE) pump with a semiconductor charge island is promising for a future quantum current standard. However, high-accuracy current in the nanoampere regime is still difficult to achieve because the performance of SE pumps tends to degrade significantly at frequencies exceeding 1 GHz. Here, we demonstrate robust SE pumping via a single-trap level in silicon up to 7.4 GHz, at which the pumping current exceeds 1 nA. An accuracy test with an uncertainty of about one part per million (ppm) reveals that the pumping current deviates from the ideal value by only about 20 ppm at the flattest part of the current plateau. This value is two orders of magnitude better than the best one reported in the nanoampere regime. In addition, the pumping accuracy is almost unchanged up to 7.4 GHz, probably due to strong electron confinement in the trap. These results indicate that trap-mediated SE pumping is promising for achieving the practical operation of the quantum current standard. PMID:28322339

  6. Noncontrast perfusion single-photon emission CT/CT scanning: a new test for the expedited, high-accuracy diagnosis of acute pulmonary embolism.

    Science.gov (United States)

    Lu, Yang; Lorenzoni, Alice; Fox, Josef J; Rademaker, Jürgen; Vander Els, Nicholas; Grewal, Ravinder K; Strauss, H William; Schöder, Heiko

    2014-05-01

    Standard ventilation and perfusion (V˙/Q˙) scintigraphy uses planar images for the diagnosis of pulmonary embolism (PE). To evaluate whether tomographic imaging improves the diagnostic accuracy of the procedure, we compared noncontrast perfusion single-photon emission CT (Q˙-SPECT)/CT scans with planar V˙/Q˙scans in patients at high risk for PE. Between 2006 and 2010, most patients referred for diagnosis of PE underwent both Q˙-SPECT/CT scan and planar V˙/Q˙scintigraphy. All scans were reviewed retrospectively by four observers; planar scans were read with modified Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) II and Prospective Investigative Study of Pulmonary Embolism Diagnosis (PISA-PED) criteria. On Q˙-SPECT/CT scan, any wedge-shaped peripheral perfusion defect occupying > 50% of a segment without corresponding pulmonary parenchymal or pleural disease was considered to show PE. The final diagnosis was established with a composite reference standard that included ECG, ultrasound of lower-extremity veins, D-dimer levels, CT pulmonary angiography (when available), and clinical follow-up for at least 3 months. One hundred six patients with cancer and mean Wells score of 4.4 had sufficient follow-up; 22 patients were given a final diagnosis of PE, and 84 patients were given a final diagnosis of no PE. According to PIOPED II, 13 studies were graded as intermediate probability. Sensitivity and specificity for PE were 50% and 98%, respectively, based on PIOPED II criteria; 86% and 93%, respectively, based on PISA-PED criteria; and 91% and 94%, respectively, based on Q˙-SPECT/CT scan. Seventy-six patients had additional relevant findings on the CT image of the Q˙-SPECT/CT scan. Noncontrast Q˙-SPECT/CT imaging has a higher accuracy than planar V˙/Q˙imaging based on PIOPED II criteria in patients with cancer and a high risk for PE.

  7. The Effect of High School Socioeconomic Status on the Predictive Validity of SAT Scores and High School Grade-Point Average

    Science.gov (United States)

    Zwick, Rebecca; Himelfarb, Igor

    2011-01-01

    Research has often found that, when high school grades and SAT scores are used to predict first-year college grade-point average (FGPA) via regression analysis, African-American and Latino students, are, on average, predicted to earn higher FGPAs than they actually do. Under various plausible models, this phenomenon can be explained in terms of…

  8. DURA-Peel, DURACON-Based Removable High Accuracy IR Thermography Coatings Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Fiber reinforced composite materials are used extensively in aerospace applications due to their high stiffness and strength to weight ratio, and superior thermal,...

  9. Women with high scores for cognitive dietary restraint choose foods lower in fat and energy.

    Science.gov (United States)

    Rideout, Candice A; McLean, Judy A; Barr, Susan I

    2004-07-01

    Women with high dietary restraint typically report restricting energy intake and using reduced-kilocalorie foods in an effort to achieve or maintain a certain body weight. However, previous studies of food choices associated with dietary restraint have been limited by the self-report of participants' food selections. We provided all foods consumed during a free-living 24-hour period to 62 normal-weight women with high (n=33) or low (n=29) dietary restraint, and observed choices from among similar foods varying in fat, fiber, and energy content. Women with high dietary restraint consumed less energy and chose reduced-kilocalorie and reduced-fat foods more frequently than unrestrained eaters. Group differences in choices of milk, cream cheese, mayonnaise, salad dressing, and soda were noted. Dietitians may consider frequent use of reduced-kilocalorie and reduced-fat foods a potential indicator of high dietary restraint, which may have health consequences. Accordingly, further exploration of clients' tendency to restrict dietary intake may be warranted.

  10. Misery in Dark Shadows behind the High Achievement Scores in South Korean Schooling: An Ethnographic Study

    Science.gov (United States)

    Kwon, Soonjung; Kristjánsson, Kristján; Walker, David I.

    2017-01-01

    This article explores some of the hidden background behind the highly praised school results in South Korea. An ethnographic case study is used to cast light on how schooling is actually experienced by South Korean students. Two main results are reported from these data. First, evidence is presented of damaging "cultural elements" such…

  11. Scoring system for the selection of high-risk patients in the intensive care unit

    NARCIS (Netherlands)

    Iapichino, G; Mistraletti, G; Corbella, D; Bassi, G; Borotto, E; Miranda, DR; Morabito, A

    2006-01-01

    Objective. Patients admitted to the intensive care unit greatly differ in severity and intensity of care. We devised a system for selecting high-risk patients that reduces bias by excluding low-risk patients and patients with an early death irrespective of the treatment. Design: A posteriori analysi

  12. Misery in Dark Shadows behind the High Achievement Scores in South Korean Schooling: An Ethnographic Study

    Science.gov (United States)

    Kwon, Soonjung; Kristjánsson, Kristján; Walker, David I.

    2017-01-01

    This article explores some of the hidden background behind the highly praised school results in South Korea. An ethnographic case study is used to cast light on how schooling is actually experienced by South Korean students. Two main results are reported from these data. First, evidence is presented of damaging "cultural elements" such…

  13. The effect of histidine on mental fatigue and cognitive performance in subjects with high fatigue and sleep disruption scores.

    Science.gov (United States)

    Sasahara, Ikuko; Fujimura, Naoko; Nozawa, Yoshizu; Furuhata, Yasufumi; Sato, Hitoshi

    2015-08-01

    Our previous study reported that a dried bonito broth known in Japan as 'dashi' improved or ameliorated mood states, including fatigue, during the daily lives of human subjects. Histidine is an amino acid that is present in dried bonito broth, and we sought to evaluate whether histidine would affect feelings of fatigue in humans. We investigated the effects of histidine intake on the feeling of fatigue, mood states and mental task performance by performing a placebo-controlled, double-blind crossover trial. Twenty subjects with high fatigue and sleep disruption scores were asked to ingest histidine or a placebo every day for two weeks. The subjects' mood states were evaluated using the Profile of Mood States (POMS) scale and a visual analog scale (VAS) for eight feelings (fatigue, depression, carelessness, drowsiness, clear thinking, motivation, attentiveness and concentration). We also measured subjects' cognitive performance using the CogHealth test battery. The fatigue T-scores on the POMS test decreased significantly following histidine ingestion compared to placebo ingestion (phistidine ingestion, the reaction time for the working memory task in the CogHealth test battery was significantly shorten compared to placebo ingestion. The VAS scores for clear thinking and for attentiveness were increased significantly following histidine ingestion compared to placebo ingestion (phistidine may ameliorate feelings of fatigue, increase performance during working memory tasks, and improve the clear thinking and attentiveness.

  14. Interethnic differences in the accuracy of anthropometric indicators of obesity in screening for high risk of coronary heart disease

    Science.gov (United States)

    Herrera, VM; Casas, JP; Miranda, JJ; Perel, P; Pichardo, R; González, A; Sanchez, JR; Ferreccio, C; Aguilera, X; Silva, E; Oróstegui, M; Gómez, LF; Chirinos, JA; Medina-Lezama, J; Pérez, CM; Suárez, E; Ortiz, AP; Rosero, L; Schapochnik, N; Ortiz, Z; Ferrante, D; Diaz, M; Bautista, LE

    2009-01-01

    Background Cut points for defining obesity have been derived from mortality data among Whites from Europe and the United States and their accuracy to screen for high risk of coronary heart disease (CHD) in other ethnic groups has been questioned. Objective To compare the accuracy and to define ethnic and gender-specific optimal cut points for body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) when they are used in screening for high risk of CHD in the Latin-American and the US populations. Methods We estimated the accuracy and optimal cut points for BMI, WC and WHR to screen for CHD risk in Latin Americans (n=18 976), non-Hispanic Whites (Whites; n=8956), non-Hispanic Blacks (Blacks; n=5205) and Hispanics (n=5803). High risk of CHD was defined as a 10-year risk ≥20% (Framingham equation). The area under the receiver operator characteristic curve (AUC) and the misclassification-cost term were used to assess accuracy and to identify optimal cut points. Results WHR had the highest AUC in all ethnic groups (from 0.75 to 0.82) and BMI had the lowest (from 0.50 to 0.59). Optimal cut point for BMI was similar across ethnic/gender groups (27 kg/m2). In women, cut points for WC (94 cm) and WHR (0.91) were consistent by ethnicity. In men, cut points for WC and WHR varied significantly with ethnicity: from 91 cm in Latin Americans to 102 cm in Whites, and from 0.94 in Latin Americans to 0.99 in Hispanics, respectively. Conclusion WHR is the most accurate anthropometric indicator to screen for high risk of CHD, whereas BMI is almost uninformative. The same BMI cut point should be used in all men and women. Unique cut points for WC and WHR should be used in all women, but ethnic-specific cut points seem warranted among men. PMID:19238159

  15. High Accuracy Investigation of Microwave Absorption in Polymer Electrical Components on Motherboard of Computers

    Science.gov (United States)

    Dašić, P.; Hutanu, C.; Jevremović, V.; Dobra, R.; Risteiu, M.; Ileana, I.

    2017-06-01

    Electronic operating at high frequencies can have problems with emission of high frequency noise. Once put inside an enclosure, the energy will add in phase at certain frequencies to cause resonances which will hinder the performance of the device. These absorbers are based upon open celled foam impregnated with a carbon coating. It is quite possible that in the near future, microprocessors would be to work on a frequency located in 5 to 10 GHz. In these circumstances it is useful to know how and how much of the electromagnetic field emitted by a microprocessor, it is absorbed by the circuit elements in the immediate vicinity of the microprocessor. The aim of this contribution is to demonstrate throughout high-level experimental analysis how the main electric parameters of polymer materials, which build the printed circuits and the one of electric capacitors and resistors, depend on the frequencies on which they work from the microwave range.

  16. Bayesian approach increases accuracy when selecting cowpea genotypes with high adaptability and phenotypic stability.

    Science.gov (United States)

    Barroso, L M A; Teodoro, P E; Nascimento, M; Torres, F E; Dos Santos, A; Corrêa, A M; Sagrilo, E; Corrêa, C C G; Silva, F A; Ceccon, G

    2016-03-11

    This study aimed to verify that a Bayesian approach could be used for the selection of upright cowpea genotypes with high adaptability and phenotypic stability, and the study also evaluated the efficiency of using informative and minimally informative a priori distributions. Six trials were conducted in randomized blocks, and the grain yield of 17 upright cowpea genotypes was assessed. To represent the minimally informative a priori distributions, a probability distribution with high variance was used, and a meta-analysis concept was adopted to represent the informative a priori distributions. Bayes factors were used to conduct comparisons between the a priori distributions. The Bayesian approach was effective for selection of upright cowpea genotypes with high adaptability and phenotypic stability using the Eberhart and Russell method. Bayes factors indicated that the use of informative a priori distributions provided more accurate results than minimally informative a priori distributions.

  17. Scoring with composites : high performance sports technology harnessed to develop advanced oilpatch products

    Energy Technology Data Exchange (ETDEWEB)

    Smith, M.

    2001-05-01

    Fiberspar Corporation, a producer of high performance sporting goods, formed a partnership with Calgary-based Thread Tech Energy Systems Ltd. to launch a new advanced composite materials technology into the Canadian market. In 1986 Fiberspar developed its LinePipe product, a high-pressure, corrosion resistant pipe made in continuous lengths of up to eight kilometres. LinePipe consists of an inner thermoplastic pressure layer reinforced with high-strength glass or carbon fibres embedded in an epoxy matrix. It can be used for surface installations in production gathering and injection or disposal applications. A newly developed fibre-reinforced spoolable pipe is currently under development and undergoing field-testing as production tubing and coiled tubing to determine it s feasibility for permanent down-hole installations for completion orf corrosive production or injection wells, or for secondary completion of existing wells for gas-lift or velocity strings. In addition, another product called SmartPipe is also undergoing field trials. The SmartPipe incorporates fiber optics, copper signal wires, power cables and capillary tubes directly into the structural wall of the composite tubing during manufacturing. This intelligent wire provides real-time reservoir monitoring and data communication while moving oil and gas from downhole or on the surface for optimal reservoir treatments. 2 figs.

  18. Outcomes of Critical Limb Ischemia in an Urban, Safety Net Hospital Population with High WIfI Amputation Scores.

    Science.gov (United States)

    Ward, Robert; Dunn, Joie; Clavijo, Leonardo; Shavelle, David; Rowe, Vincent; Woo, Karen

    2017-01-01

    Patients presenting to a public hospital with critical limb ischemia (CLI) typically have advanced disease with significant comorbidities. The purpose of this study was to assess the influence of revascularization on 1-year amputation rate of CLI patients presenting to Los Angeles County USC Medical Center, classified according to the Society for Vascular Surgery Wound, Ischemia and foot Infection (WIfI). A retrospective review of patients who presented to a public hospital with CLI from February 2010 to July 2014 was performed. Patients were classified according to the WIfI system. Only patients with complete data who survived at least 12 months after presentation were included. Ninety-three patients with 98 affected limbs were included. The mean age was 62.8 years. Eighty-two patients (84%) had hypertension and 71 (72%) had diabetes. Fifty (57.5%) limbs had Trans-Atlantic Inter-Society Consensus (TASC) C or D femoral-popliteal lesions and 82 (98%) had significant infrapopliteal disease. The majority had moderate or high WIfI amputation and revascularization scores. Eighty-four (86%) limbs underwent open, endovascular, or hybrid revascularization. Overall, one year major amputation (OYMA) rate was 26.5%. In limbs with high WIfI amputation score, the OYMA was 34.5%: 21.4% in those who were revascularized and 57% in those who were not. On univariable analysis, factors associated with increased risk of OYMA were nonrevascularization (P = 0.005), hyperlipidemia (P = 0.06), hemodialysis (P = 0.005), gangrene (P = 0.02), ulcer classification (P = 0.05), WIfI amputation score (P = 0.026), and WIfI wound grade (P = 0.04). On multivariable analysis, increasing WIfI amputation score (odds ratio [OR] 1.84, 95% confidence interval [CI] 1.0-3.39) was associated with increased risk of OYMA while revascularization (OR 0.24, 95% CI 0.07-0.80) was associated with decreased risk of OYMA. The OYMA rates in this population were consistent with those predicted by the

  19. Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Zhou, Chang Sheng; Zhao, Yan E.; Li, Xie; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Wang, Yining; Cao, Jian; Jin, Zhengyu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Schoepf, U.J. [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Meinel, Felix G. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Ludwig-Maximilians-University Hospital, Institute for Clinical Radiology, Munich (Germany); Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Gong, Jian Bin [Jinling Hospital, Medical School of Nanjing University, Department of Cardiology, Nanjing, Jiangsu (China)

    2016-03-15

    To investigate image quality, radiation dose, and diagnostic performance of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) at 70 kVp compared to invasive coronary angiography (ICA) as reference standard. Forty-three patients underwent prospectively ECG-triggered high-pitch CCTA at 70 kVp using 30 cc (11 g iodine) contrast medium and ICA. Subjective and objective image quality was evaluated for each CCTA study. CCTA performance for diagnosing ≥50 % stenosis was assessed. Results were stratified according to heart rate (HR), body mass index (BMI), Agatston score, and image quality. At CCTA, 94.3 % (500/530) of coronary segments were of diagnostic quality. Using ICA as reference standard, sensitivity and accuracy were 100 % and 93.0 % on a per-patient basis. Per-vessel and per-segment performances were 92.2 % and 89.5 %; 79.5 % and 88.3 %, respectively. No differences were found in diagnostic accuracy between different HR, BMI, and calcification subgroups (all P > 0.05) on a per-patient basis. However, low image quality reduced diagnostic accuracy on a per-patient, per-vessel and per-segment basis (all P < 0.05). The mean effective radiation dose was 0.2 ± 0.0 mSv. Our presented protocol results in an effective radiation dose of 0.2 mSv and high diagnostic accuracy for stenosis detection in a selected, non-obese population. (orig.)

  20. Mode-resolved frequency comb interferometry for high-accuracy long distance measurement

    NARCIS (Netherlands)

    Van den Berg, S.A.; Van Eldik, S.; Bhattacharya, N.

    2015-01-01

    Optical frequency combs have developed into powerful tools for distance metrology. In this paper we demonstrate absolute long distance measurement using a single femtosecond frequency comb laser as a multi-wavelength source. By applying a high-resolution spectrometer based on a virtually imaged phas

  1. Novel method of high-accuracy wavefront-phase and amplitude correction for coronagraphy

    Science.gov (United States)

    Bowers, Charles W.; Woodgate, Bruce E.; Lyon, Richard G.

    2003-11-01

    Detection of extra-solar, and especially terrestrial-like planets, using coronagraphy requires an extremely high level of wavefront correction. For example, the study of Woodruff et al. (2002) has shown that phase uniformity of order 10-4λ(rms) must be achieved over the critical range of spatial frequencies to produce the ~1010 contrast needed for the Terrestrial Planet Finder (TPF) mission. Correction of wavefront phase errors to this level may be accomplished by using a very high precision deformable mirror (DM). However, not only phase but also amplitude uniformity of the same scale (~10-4) and over the same spatial frequency range must be simultaneously obtained to remove all residual speckle in the image plane. We present a design for producing simultaneous wavefront phase and amplitude uniformity to high levels from an input wavefront of lower quality. The design uses a dual Michelson interferometer arrangement incorporating two DM and a single, fixed mirror (all at pupils) and two beamsplitters: one with unequal (asymmetric) beam splitting and one with symmetric beam splitting. This design allows high precision correction of both phase and amplitude using DM with relatively coarse steps and permits a simple correction algorithm.

  2. High-accuracy alignment based on atmospherical dispersion - technological approaches and solutions for the dual-wavelength transmitter

    Energy Technology Data Exchange (ETDEWEB)

    Burkhard, Boeckem [Institute for Geodesy and Photogrammetry, ETH Zurich (Switzerland)

    1999-07-01

    In the course of the progressive developments of sophisticated geodetic systems utilizing electromagnetic waves in the visible or near IR-range a more detailed knowledge of the propagation medium and coevally solutions of atmospherically induced limitations will become important. An alignment system based on atmospherical dispersion, called a dispersometer, is a metrological solution to the atmospherically induced limitations, in optical alignment and direction observations of high accuracy. In the dispersometer we are using the dual-wavelength method for dispersive air to obtain refraction compensated angle measurements, the detrimental impact of atmospheric turbulence notwithstanding. The principle of the dual-wavelength method utilizes atmospherical dispersion, i.e. the wavelength dependence of the refractive index. The difference angle between two light beams of different wavelengths, which is called the dispersion angle {delta}{beta}, is to first approximation proportional to the refraction angle: {beta}{sub IR} {nu}({beta}{sub blue} - {beta}{sub IR}) = {nu} {delta}{beta}, this equation implies that the dispersion angle has to be measured at least 42 times more accurate than the desired accuracy of the refraction angle for the wavelengths used in the present dispersometer. This required accuracy constitutes one major difficulty for the instrumental performance in applying the dispersion effect. However, the dual-wavelength method can only be successfully used in an optimized transmitter-receiver combination. Beyond the above mentioned resolution requirement for the detector, major difficulties in instrumental realization arise in the availability of a suitable dual-wavelength laser light source, laser light modulation with a very high extinction ratio and coaxial emittance of mono-mode radiation at both wavelengths. Therefore, this paper focuses on the solutions of the dual-wavelength transmitter introducing a new hardware approach and a complete re-design of

  3. High-accuracy identification and bioinformatic analysis of in vivo protein phosphorylation sites in yeast

    DEFF Research Database (Denmark)

    Gnad, Florian; de Godoy, Lyris M F; Cox, Jürgen

    2009-01-01

    mapped to 1118 proteins, representatively covering the yeast kinome and a multitude of transcription factors. We show that a single false discovery rate for all peptide identifications significantly overestimates occurrence of rare modifications, such as tyrosine phosphorylation in yeast. The identified...... phosphorylation sites are predominantly located on irregularly structured and accessible protein regions. We found high evolutionary conservation of phosphorylated proteins and a large overlap of significantly over-represented motifs with the human phosphoproteome. Nevertheless, phosphorylation events at the site...... level were not highly conserved between yeast and higher eukaryotes, which points to metazoan-specific kinase and substrate families. We constructed a yeast-specific phosphorylation sites predictor on the basis of a support vector machine, which - together with the yeast phosphorylation data...

  4. High accuracy and precision micro injection moulding of thermoplastic elastomers micro ring production

    DEFF Research Database (Denmark)

    Calaon, Matteo; Tosello, Guido; Elsborg, René

    2016-01-01

    of using tool geometries as reference calibrated artefacts to establish effective process technology development and control. The results allow identifying the correct process windows for optimal part quality reducing product dimensional variation in the micrometer dimensional range. The proposed......The mass-replication nature of the process calls for fast monitoring of process parameters and product geometrical characteristics. In this direction, the present study addresses the possibility to develop a micro manufacturing platform for micro assembly injection moulding with real-time process/product...... monitoring and metrology. The study represent a new concept yet to be developed with great potential for high precision mass-manufacturing of highly functional 3D multi-material (i.e. including metal/soft polymer) micro components. The activities related to HINMICO project objectives proves the importance...

  5. Challenges in high accuracy surface replication for micro optics and micro fluidics manufacture

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Calaon, Matteo;

    2014-01-01

    by replication technologies such as nickel electroplating. All replication steps are enabled by a high precision master and high reproduction fidelity to ensure that the functionalities associated with the design are transferred to the final component. Engineered surface micro structures can be either......Patterning the surface of polymer components with microstructured geometries is employed in optical and microfluidic applications. Mass fabrication of polymer micro structured products is enabled by replication technologies such as injection moulding. Micro structured tools are also produced...... distributed, e.g., to create an optical pattern, or discretised, e.g., as micro channels for fluids manipulation. Key aspects of two process chains based on replication technologies for both types of micro structures are investigated: lateral replication fidelity, dimensional control at micro scale, edge...

  6. Modelling and Control of Stepper Motors for High Accuracy Positioning Systems Used in Radioactive Environments

    OpenAIRE

    Picatoste Ruilope, Ricardo

    2014-01-01

    Hybrid Stepper Motors are widely used in open-loop position applications. They are the choice of actuation for the collimators in the Large Hadron Collider, the largest particle accelerator at CERN. In this case the positioning requirements and the highly radioactive operating environment are unique. The latter forces both the use of long cables to connect the motors to the drives which act as transmission lines and also prevents the use of standard position sensors. However, reliable and pre...

  7. The Ultrasonic Piezo Drive an Innovative Solution for High-Accuracy Positioning

    OpenAIRE

    Seiler, René; Six, Marc; Debornot, Miguel; Le Letty, Ronan; CLAEYSSEN, Frank

    2002-01-01

    Piezo-electric motors have been successfully developed for various applications like autofocus drives in camera lenses and handling equipment for semiconductor production. Their high speed and accurate positioning capability, combined with a favourable holding torque in unpowered condition, make piezo motors also very attractive for actuation purposes in spacecraft mechanisms. However, so far only a few studies have been reported considering their suitability for actual use in space. Piezo mo...

  8. High-Accuracy Methods for Numerical Flow Analysis Using Adaptive Non-Linear Wavelets

    Science.gov (United States)

    2012-08-01

    to the research by Bacry, Mallat and Papanicolaou [10] or Holmström and Walden [11], AWGM solves PDE problems in a wavelet coefficient space. It is...of the threshold value, these variations are discarded and restricted by multiplying the weighting factor . This process can especially contribute the...weighting factor . This restriction technique enhances the convergence rate of steady state calculations. References [1] Harten A., “High

  9. High accuracy measure of atomic polarizability in an optical lattice clock

    OpenAIRE

    Sherman, J. A.; Lemke, N. D.; Hinkley, N.; Pizzocaro, M.; Fox, R. W.; Ludlow, A. D.; Oates, C. W.

    2011-01-01

    Despite being a canonical example of quantum mechanical perturbation theory, as well as one of the earliest observed spectroscopic shifts, the Stark effect contributes the largest source of uncertainty in a modern optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (suc...

  10. Two-dimensional DOA Estimation with High Accuracy for MIMO Radar Using Cross Array

    Directory of Open Access Journals (Sweden)

    Liang Hao

    2016-06-01

    Full Text Available In this study, we investigate the estimation of the Two-Dimensional (2D Direction Of Arrival (DOA in monostatic multiple-input–multiple-output radar with cross array and propose a novel, highly accurate DOA estimation method based on unitary transformation. First, we design a new unitary matrix using the central symmetry of a cross array at transmit and receive sites. Then, the rotational invariance relationships of these arrays with long and short baselines can be transformed into a real-value field via unitary transformation. In addition, non-ambiguous and highly accurate 2D DOA estimations can be obtained using a unitary dual-resolution ESPRIT algorithm. Simulations show that the proposed method can estimate 2D highly accurate spatial angles using automatic pairing without incurring the expense of array aperture and peak searching. Compared with traditional unitary transformation, the steering vectors of transmit and receive arrays can be transformed into real-value fields via the unitary matrix and the transformation method of our scheme, respectively. This effectively overcomes the problem of shift invariance factors in real-value fields that cannot be extracted using traditional algorithms. Therefore, the proposed method can absolutely compute eigenvalue decomposition and estimate parameters in a real-value field, resulting in lower computational complexity compared with traditional methods. Simulation results verify both the correctness of our theoretical analysis and the effectiveness of the proposed algorithm.

  11. Accuracy optimization of high-speed AFM measurements using Design of Experiments

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, F.; Hansen, Hans Nørgaard

    2010-01-01

    , the estimated dimensions of measured features. The definition of scan settings is based on a comprehensive optimization that targets maximization of information from collected data and minimization of measurement uncertainty and scan time. The Design of Experiments (DOE) technique is proposed and applied......Atomic Force Microscopy (AFM) is being increasingly employed in industrial micro/nano manufacturing applications and integrated into production lines. In order to achieve reliable process and product control at high measuring speed, instrument optimization is needed. Quantitative AFM measurement...

  12. Energy-preserving numerical schemes of high accuracy for one-dimensional Hamiltonian systems

    CERN Document Server

    Cieśliński, Jan L

    2011-01-01

    We present a class of non-standard numerical schemes which are modifications of the discrete gradient method. They preserve the energy integral exactly (up to the round-off error). The considered class contains locally exact discrete gradient schemes and integrators of arbitrary high order. In numerical experiments we compare our integrators with some other numerical schemes, including the standard discrete gradient method, the leap-frog scheme and a symplectic scheme of 4th order. We study the error accumulation for very long time and the conservation of the energy integral.

  13. A three axis turntable's online initial state measurement method based on the high-accuracy laser gyro SINS

    Science.gov (United States)

    Gao, Chunfeng; Wei, Guo; Wang, Qi; Xiong, Zhenyu; Wang, Qun; Long, Xingwu

    2016-10-01

    As an indispensable equipment in inertial technology tests, the three-axis turntable is widely used in the calibration of various types inertial navigation systems (INS). In order to ensure the calibration accuracy of INS, we need to accurately measure the initial state of the turntable. However, the traditional measuring method needs a lot of exterior equipment (such as level instrument, north seeker, autocollimator, etc.), and the test processing is complex, low efficiency. Therefore, it is relatively difficult for the inertial measurement equipment manufacturers to realize the self-inspection of the turntable. Owing to the high precision attitude information provided by the laser gyro strapdown inertial navigation system (SINS) after fine alignment, we can use it as the attitude reference of initial state measurement of three-axis turntable. For the principle that the fixed rotation vector increment is not affected by measuring point, we use the laser gyro INS and the encoder of the turntable to provide the attitudes of turntable mounting plat. Through this way, the high accuracy measurement of perpendicularity error and initial attitude of the three-axis turntable has been achieved.

  14. High accuracy indirect optical manipulation of live cells with functionalized microtools

    Science.gov (United States)

    Vizsnyiczai, Gaszton; Aekbote, Badri L.; Buzás, András.; Grexa, István.; Ormos, Pál.; Kelemen, Lóránd

    2016-09-01

    Optical micro manipulation of live cells has been extensively used to study a wide range of cellular phenomena with relevance in basic research or in diagnostics. The approaches span from manipulation of many cells for high throughput measurement or sorting, to more elaborated studies of intracellular events on trapped single cells when coupled with modern imaging techniques. In case of direct cell trapping the damaging effects of light-cell interaction must be minimized, for instance with the choice of proper laser wavelength. Microbeads have already been used for trapping cells indirectly thereby reducing the irradiation damage and increasing trapping efficiency with their high refractive index contrast. We show here that such intermediate objects can be tailor-made for indirect cell trapping to further increase cell-to-focal spot distance while maintaining their free and fast maneuverability. Carefully designed structures were produced with two-photon polymerization with shapes optimized for effective manipulation and cell attachment. Functionalization of the microstructures is also presented that enables cell attachment to them within a few seconds with strength much higher that the optical forces. Fast cell actuation in 6 degrees of freedom is demonstrated with the outlook to possible applications in cell imaging.

  15. Automated high-accuracy mutation screening with the WAVE nucleic acid fragment analysis system

    Science.gov (United States)

    Hecker, Karl H.

    2002-06-01

    The analysis of DNA fragments by ion-pair reversed-phase high-performance liquid chromatography on an alkylated, nonporous poly(styrene-divinylbenzene) matrix (DNA Cartridge) using the WAVE Nucleic Acid Fragment Analysis System is a powerful and versatile tool for DNA analysis. Resolution of DNA fragments is based on two principles, size-dependent retention of double-stranded (ds) DNA and differential retention of ds vs. single-stranded (ss) DNA. Temperature Modulated Heteroduplex Analysis utilizes both principles of separation to detect single nucleotide polymorphisms (SNP) and short insertions/deletions. At a given temperature the difference in the melting between homo- and heteroduplexes is revealed by differences in retention times. The temperature at which differential melting occurs is sequence dependent and is predicated accurately using either WAVEMAKER or WAVE Navigator software, which use a modified Fixman-Friere algorithm. Detection of known and unknown sequence variations can be performed on DNA fragments of up to 1,000 base pairs with high sensitivity and specificity. The use of fluorescent labels is compatible with the technology and increases sensitivity. Retention times are increased and resolution is not affected. Fluorescent labeling significantly increases sensitivity.

  16. High-accuracy measurement of the emission spectrum of liquid xenon in the vacuum ultraviolet region

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Keiko, E-mail: fujii-keiko-nv@ynu.jp [Faculty of Engineering, Yokohama National University, Yokohama, Kanagawa 240-8501 (Japan); Endo, Yuya; Torigoe, Yui; Nakamura, Shogo [Faculty of Engineering, Yokohama National University, Yokohama, Kanagawa 240-8501 (Japan); Haruyama, Tomiyoshi; Kasami, Katsuyu [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); Mihara, Satoshi; Saito, Kiwamu; Sasaki, Shinichi [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); The Graduate School of Advanced Studies, Hayama, Kanagawa 240-0193 (Japan); Tawara, Hiroko [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan)

    2015-09-21

    The emission spectrum of cryogenic liquid xenon in the vacuum ultraviolet region was measured by irradiating liquid xenon with gamma-rays from a radioactive source. To achieve a high signal-to-noise ratio, we employed coincident photon counting. Additionally, the charge of the photo-sensor signals was measured to estimate the number of detected photons accurately. In addition, proper corrections were incorporated for the wavelength; response functions of the apparatus obtained using a low-pressure mercury lamp, and photon detection efficiencies of the optical system were considered. The obtained emission spectrum is found to be in the shape of a Gaussian function, with the center at 57,199±34 (stat.)±33 (syst.) cm{sup −1} (174.8±0.1 (stat.)±0.1 (syst.) nm) and the full width at half maximum of 3328±72 (stat.)±65 (syst.) cm{sup −1} (10.2±0.2 (stat.)±0.2 (sys.) nm). These results are the most accurate values obtained in terms of the data acquisition method and the calibration for the experimental system and provide valuable information regarding the high-precision instruments that employ a liquid-xenon scintillator.

  17. Modelling and Control of Stepper Motors for High Accuracy Positioning Systems Used in Radioactive Environments

    CERN Document Server

    Picatoste Ruilope, Ricardo; Masi, Alessandro

    Hybrid Stepper Motors are widely used in open-loop position applications. They are the choice of actuation for the collimators in the Large Hadron Collider, the largest particle accelerator at CERN. In this case the positioning requirements and the highly radioactive operating environment are unique. The latter forces both the use of long cables to connect the motors to the drives which act as transmission lines and also prevents the use of standard position sensors. However, reliable and precise operation of the collimators is critical for the machine, requiring the prevention of step loss in the motors and maintenance to be foreseen in case of mechanical degradation. In order to make the above possible, an approach is proposed for the application of an Extended Kalman Filter to a sensorless stepper motor drive, when the motor is separated from its drive by long cables. When the long cables and high frequency pulse width modulated control voltage signals are used together, the electrical signals difer greatl...

  18. Improving the diagnostic accuracy of acute myocardial infarction with the use of high-sensitive cardiac troponin T in different chronic kidney disease stages

    Science.gov (United States)

    Yang, Hongliu; Liu, Jing; Luo, Han; Zeng, Xiaoxi; Tang, Xi; Ma, Liang; Mai, Hongxia; Gou, Shenju; Liu, Fang; Fu, Ping

    2017-01-01

    High-sensitive cardiac troponin T (hs-TnT) is a critical biomarker in diagnosis of acute myocardial infarction (AMI). However, CKD individuals usually have elevated hs-TnT even in the absence of AMI. Our study aimed to explore the optimal cutoff-value of hs-TnT and further to improve diagnostic accuracy of AMI in CKD patients. Clinical data of 489 patients were collected from the maintained database between September 2010 and June 2014. CKD patients with AMI were assigned to CKD+AMI group and CKD patients without AMI were assigned to CKD group. Receiver operating characteristic curves were utilized to derive the optimal cutoff-value. In CKD+STEMI and CKD group, hs-TnT was increased with descending eGFR. In CKD+NSTEMI group, hs-TnT showed an upward trend with increasing SYNTAX Score. In patients with CKD+STEMI, hs-TnT was significantly correlated with SYNTAX Score in CKD stage 2, stage 4 and in total. In CKD patients, the optimal cutoff-value of hs-TnT for diagnosis of AMI was 129.45 ng/l with 75.2% sensitivity and 83.2% specificity. The cutoff-value appeared to be hs-TnT level of 99.55ng/l in CKD stage 3, 129.45 ng/l in CKD stage 4, 105.50 ng/l in CKD stage 5 and 149.35 ng/l in dialysis patients, respectively. In different stages of CKD, eGFR-range-specific optimal cutoff-values should be considered. PMID:28145489

  19. Determination of the QCD Λ Parameter and the Accuracy of Perturbation Theory at High Energies.

    Science.gov (United States)

    Dalla Brida, Mattia; Fritzsch, Patrick; Korzec, Tomasz; Ramos, Alberto; Sint, Stefan; Sommer, Rainer

    2016-10-28

    We discuss the determination of the strong coupling α_{MS[over ¯]}(m_{Z}) or, equivalently, the QCD Λ parameter. Its determination requires the use of perturbation theory in α_{s}(μ) in some scheme s and at some energy scale μ. The higher the scale μ, the more accurate perturbation theory becomes, owing to asymptotic freedom. As one step in our computation of the Λ parameter in three-flavor QCD, we perform lattice computations in a scheme that allows us to nonperturbatively reach very high energies, corresponding to α_{s}=0.1 and below. We find that (continuum) perturbation theory is very accurate there, yielding a 3% error in the Λ parameter, while data around α_{s}≈0.2 are clearly insufficient to quote such a precision. It is important to realize that these findings are expected to be generic, as our scheme has advantageous properties regarding the applicability of perturbation theory.

  20. A magnetic bearing momentum wheel for high pointing accuracy and vibration sensitive space applications

    Science.gov (United States)

    Bichler, U. J.

    The paper describes a magnetic bearing momentum wheel (MW-X) theoretically and experimentally with attention given to its low-noise application to spacecraft attitude-control systems. The MW-X gyroscopic actuator comprises a rotor, emergency bearings, a locking mechanisms, and a drive motor, and Vernier gimballing is employed so that the rotor and the momentum vector can be tilted actively with about one degree. The MW-X utilizes a suspension-control system for noise attenuation and active vibration suppression to reduce noise from the sensor surface. The actively controlled magnetic bearing wheels are shown to provide active damping of flexible structures by means of fully controllable translational bearing forces. The MW-X devices are of interest for applications to optical communications links, space telescopes, and earth-observation satellites with high resolutions.

  1. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (˜100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ˜0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  2. Ultraviolet Raman lidar for high-accuracy profiling of aerosol extinction coefficient

    Institute of Scientific and Technical Information of China (English)

    Fei Gao; Xiaoquan Song; Yufeng Wang; Yi Zhou; Dengxin Hua

    2009-01-01

    An ultraviolet (UV) Raman lidar system at 354.7 nm has been developed for accurately measuring the aerosol extinction profiles. A spectroscopic filter combining a high-spectral-resolution grating with two narrowband mirrors is used to separate the vibrational Raman scattering signal of N2 at a central wave-length of 386.7 nm and the elastic scattering signal at 354.7 nm. The aerosol extinction is derived from the Raman scattering of N2 and the elastic scattering by the use of Raman method and Klett method, respectively. The derived results of aerosol extinction are used to compare the difference of two retrieval methods, and the preliminary experiment shows that the Raman lidar system operated in analog detection mode has the capability of measuring aerosol profiles up to a height of 3 km with a laser energy of 250 mJ and an integration time of 8 min.

  3. High Accuracy Tracking of Space-Borne Non-Cooperative Targets

    DEFF Research Database (Denmark)

    Pedersen, David Arge Klevang

    for the spacecraft to navigate safely and autonomously towards the target. These methods are applied on three distinct study cases, which are based on the platform of the microASC instrument. In relation to the Mars2020 rover, a structured light system is used to navigate the PIXL instrument towards the Martian...... the surface and to enhance the PIXL instrument's capabilities with highly accurate distance measurements. Optical observations of planetary bodies and satellites are utilized to determine the inertial position of a spacecraft. A software module is developed, tested and verified by both ground based and in......-ight observations, where the performanceover the complete operational envelope is characterized by simulations. The in-flight observations were captured onboard Juno, during the Earth flyby, by the microASC instrument, operating as an inertially controlled imager. The involvement in Juno's Earth Fly By operational...

  4. High accuracy measurements of dry mole fractions of carbon dioxide and methane in humid air

    Directory of Open Access Journals (Sweden)

    C. W. Rella

    2012-08-01

    Full Text Available Traditional techniques for measuring the mole fractions of greenhouse gas in the well-mixed atmosphere have required extremely dry sample gas streams (dew point < −25 °C to achieve the inter-laboratory compatibility goals set forth by the Global Atmospheric Watch program of the World Meteorological Organization (WMO/GAW for carbon dioxide (±0.1 ppm and methane (±2 ppb. Drying the sample gas to low levels of water vapor can be expensive, time-consuming, and/or problematic, especially at remote sites where access is difficult. Recent advances in optical measurement techniques, in particular Cavity Ring Down Spectroscopy (CRDS, have led to the development of highly stable and precise greenhouse gas analyzers capable of highly accurate measurements of carbon dioxide, methane, and water vapor. Unlike many older technologies, which can suffer from significant uncorrected interference from water vapor, these instruments permit for the first time accurate and precise greenhouse gas measurements that can meet the WMO/GAW inter-laboratory compatibility goals without drying the sample gas. In this paper, we present laboratory methodology for empirically deriving the water vapor correction factors, and we summarize a series of in-situ validation experiments comparing the measurements in humid gas streams to well-characterized dry-gas measurements. By using the manufacturer-supplied correction factors, the dry-mole fraction measurements have been demonstrated to be well within the GAW compatibility goals up to at least 1% water vapor. By determining the correction factors for individual instruments once at the start of life, this range can be extended to at least 2% over the life of the instrument, and if the correction factors are determined periodically over time, the evidence suggests that this range can be extended above 4%.

  5. The predictability of T3 disease in staging MRI following prostate biopsy decreases in patients with high initial PSA and Gleason score

    Institute of Scientific and Technical Information of China (English)

    Young Hwii Ko; Deuk Jae Sung; Sung Gu Kang; Seok Ho Kang; Jeong Gu Lee; Je Jong Kim; Jun Cheon

    2011-01-01

    To obtain improved accuracy in predicting extracapsular extension (ECE) and seminal vesicle invasion (SVI), we evaluated the variables affecting the predictability of staging magnetic resonance imaging (MRI, phased-array coil) and estimated their impact on accuracy between preoperative MRI staging and histological outcome. A total of 121 patients with localized or locally advanced prostate cancer who underwent robotic radical prostatectomy (RALP) were included. Following transrectal biopsy, all enrolled patients had undergone MRI for staging work-up. After RALP, only 43.8% (53/121) of the patients were matched with the MRI predicted stage. Compared to the matched group in the prediction of ECE, the unmatched group had significantly higher initial prostate-specific antigen (PSA, 12.8 ng ml-1 versus 8.1 ng ml-1, P=0.048). In the prediction of SVI, initial PSA (8.1 ng ml-1 versus 17.3 ng ml-1, P=0.009) and biopsy Gleason score (6.5 versus 7.6, P=0.035) were significantly higher in the unmatched group. When applying clinical cutoffs of initial PSA of 10 and 20 ng ml-1, the accuracy of MRI in the prediction of ECE was decreased in the group with PSA over 20 ng ml-1 (75.6,64.5 and 37.5%, P=0.01), and this group had significantly decreased accuracy of MRI in the prediction of SVI (91.5,77.4 and 37.5%, P<0.01). Applying the clinical cutoff of a Gleason score of 7, the accuracy of MRI in the prediction of SVI was decreased in the higher Gleason score group (93.9,82.1 and 62.9%, P=0.01). Thus, for these patient groups, to obtain margin negativity during radical prostatectomy, operative findings, rather than post-biopsy MRI images, may provide substantial information, implying a clinical advantage in conducting MRI before prostate biopsy.

  6. Apgar Scores

    Science.gov (United States)

    ... Stages Listen Español Text Size Email Print Share Apgar Scores Page Content Article Body As soon as your ... the syringe, but is blue; her one minute Apgar score would be 8—two points off because she ...

  7. Fetal Biophysical Profile Scoring

    Directory of Open Access Journals (Sweden)

    H.R. HaghighatKhah

    2009-01-01

    Full Text Available   "nFetal biophysical profile scoring is a sonographic-based method of fetal assessment first described by Manning and Platt in 1980. "nThe biophysical profile score was developed as a method to integrate real-time observations of the fetus and his/her intrauterine environment in order to more comprehensively assess the fetal condition. These findings must be evaluated in the context of maternal/fetal history (i.e., chronic hypertension, post-dates, intrauterine growth restriction, etc, fetal structural integrity (presence or absence of congenital anomalies, and the functionality of fetal support structures (placental and umbilical cord. For example, acute asphyxia due to placental abruption may result in an absence of the acute variables of the biophysical profile score (fetal breathing movements, fetal movement, fetal tone, and fetal heart rate reactivity with a normal amniotic fluid volume. With post maturity the asphyxial event may be intermittent and chronic resulting in a decrease in amniotic fluid volume, but with the acute variables remaining normal. "nWhile the 5 components of the biophysical profile score have remained unchanged since 1980 (Manning, 1980, the definitions of a normal and abnormal parameter have evolved with increasing experience. "nIn 1984 the definition of oligohydramnios was increased from < 1cm pocket of fluid to < 2.0 x 1.0 cm pocket. Oligohydramnios is now defined as a pocket of amniotic fluid < 2.0 x 2.0 cm (Manning, 1995a "nIf the four ultrasound variables are normal, the accuracy of the biophysical profile score was not found to be significantly improved by adding the non-stress test. As a result, in 1987 the profile score was modified to incorporate the non-stress test only when one of the ultrasound variables was abnormal (Manning 1987. Table 1 outlines the current definitions for quantifying a variable as present or absent. "nEach of the 5 components of the biophysical profile score does not have equal

  8. Indexing Large Visual Vocabulary by Randomized Dimensions Hashing for High Quantization Accuracy: Improving the Object Retrieval Quality

    Science.gov (United States)

    Yang, Heng; Wang, Qing; He, Zhoucan

    The bag-of-visual-words approach, inspired by text retrieval methods, has proven successful in achieving high performance in object retrieval on large-scale databases. A key step of these methods is the quantization stage which maps the high-dimensional image feature vectors to discriminatory visual words. In this paper, we consider the quantization step as the nearest neighbor search in large visual vocabulary, and thus proposed a randomized dimensions hashing (RDH) algorithm to efficiently index and search the large visual vocabulary. The experimental results have demonstrated that the proposed algorithm can effectively increase the quantization accuracy compared to the vocabulary tree based methods which represent the state-of-the-art. Consequently, the object retrieval performance can be significantly improved by our method in the large-scale database.

  9. Social power and recognition of emotional prosody: High power is associated with lower recognition accuracy than low power.

    Science.gov (United States)

    Uskul, Ayse K; Paulmann, Silke; Weick, Mario

    2016-02-01

    Listeners have to pay close attention to a speaker's tone of voice (prosody) during daily conversations. This is particularly important when trying to infer the emotional state of the speaker. Although a growing body of research has explored how emotions are processed from speech in general, little is known about how psychosocial factors such as social power can shape the perception of vocal emotional attributes. Thus, the present studies explored how social power affects emotional prosody recognition. In a correlational study (Study 1) and an experimental study (Study 2), we show that high power is associated with lower accuracy in emotional prosody recognition than low power. These results, for the first time, suggest that individuals experiencing high or low power perceive emotional tone of voice differently.

  10. Hybrid single-packet IP traceback with low storage and high accuracy.

    Science.gov (United States)

    Yang, Ming Hour

    2014-01-01

    Traceback schemes have been proposed to trace the sources of attacks that usually hide by spoofing their IP addresses. Among these methods, schemes using packet logging can achieve single-packet traceback. But packet logging demands high storage on routers and therefore makes IP traceback impractical. For lower storage requirement, packet logging and packet marking are fused to make hybrid single-packet IP traceback. Despite such attempts, their storage still increases with packet numbers. That is why RIHT bounds its storage with path numbers to guarantee low storage. RIHT uses IP header's ID and offset fields to mark packets, so it inevitably suffers from fragment and drop issues for its packet reassembly. Although the 16-bit hybrid IP traceback schemes, for example, MORE, can mitigate the fragment problem, their storage requirement grows up with packet numbers. To solve the storage and fragment problems in one shot, we propose a single-packet IP traceback scheme that only uses packets' ID field for marking. Our major contributions are as follows: (1) our fragmented packets with tracing marks can be reassembled; (2) our storage is not affected by packet numbers; (3) it is the first hybrid single-packet IP traceback scheme to achieve zero false positive and zero false negative rates.

  11. High-accuracy acoustic detection of nonclassical component of material nonlinearity.

    Science.gov (United States)

    Haupert, Sylvain; Renaud, Guillaume; Rivière, Jacques; Talmant, Maryline; Johnson, Paul A; Laugier, Pascal

    2011-11-01

    The aim is to assess the nonclassical component of material nonlinearity in several classes of materials with weak, intermediate, and high nonlinear properties. In this contribution, an optimized nonlinear resonant ultrasound spectroscopy (NRUS) measuring and data processing protocol applied to small samples is described. The protocol is used to overcome the effects of environmental condition changes that take place during an experiment, and that may mask the intrinsic nonlinearity. External temperature fluctuation is identified as a primary source of measurement contamination. For instance, a variation of 0.1 °C produced a frequency variation of 0.01%, which is similar to the expected nonlinear frequency shift for weakly nonlinear materials. In order to overcome environmental effects, the reference frequency measurements are repeated before each excitation level and then used to compute nonlinear parameters. Using this approach, relative resonant frequency shifts of 10(-5) can be measured, which is below the limit of 10(-4) often considered as the limit of NRUS sensitivity under common experimental conditions. Due to enhanced sensitivity resulting from the correction procedure applied in this work, nonclassical nonlinearity in materials that before have been assumed to only be classically nonlinear in past work (steel, brass, and aluminum) is reported.

  12. Determination of the QCD Λ-parameter and the accuracy of perturbation theory at high energies

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Brida, Mattia [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Fritzsch, Patrick [Univ. Autonoma de Madrid (Spain). Inst. de Fisica Teorica UAM/CSIC; Korzec, Tomasz [Wuppertal Univ. (Germany). Dept. of Physics; Ramos, Alberto [CERN - European Organization for Nuclear Research, Geneva (Switzerland). Theory Div.; Sint, Stefan [Trinity College Dublin (Ireland). School of Mathematics; Sommer, Rainer [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik; Collaboration: ALPHA Collaboration

    2016-04-15

    We discuss the determination of the strong coupling α{sub MS}(m{sub Z}) or equivalently the QCD Λ-parameter. Its determination requires the use of perturbation theory in α{sub s}(μ) in some scheme, s, and at some energy scale μ. The higher the scale μ the more accurate perturbation theory becomes, owing to asymptotic freedom. As one step in our computation of the Λ-parameter in three-flavor QCD, we perform lattice computations in a scheme which allows us to non-perturbatively reach very high energies, corresponding to α{sub s}=0.1 and below. We find that (continuum) perturbation theory is very accurate there, yielding a three percent error in the Λ-parameter, while data around α{sub s}∼0.2 is clearly insufficient to quote such a precision. It is important to realize that these findings are expected to be generic, as our scheme has advantageous properties regarding the applicability of perturbation theory.

  13. Temporal Stability of the Velodyne HDL-64E S2 Scanner for High Accuracy Scanning Applications

    Directory of Open Access Journals (Sweden)

    Craig Glennie

    2011-03-01

    Full Text Available The temporal stability and static calibration and analysis of the Velodyne HDL‑64E S2 scanning LiDAR system is discussed and analyzed. The mathematical model for measurements for the HDL-64E S2 scanner is updated to include misalignments between the angular encoder and scanner axis of rotation, which are found to be a marginally significant source of error. It is reported that the horizontal and vertical laser offsets cannot reliably be obtained with the current calibration model due to their high correlation with the horizontal and vertical offsets. By analyzing observations from two separate HDL-64E S2 scanners it was found that the temporal stability of the horizontal angle offset is near the quantization level of the encoder, but the vertical angular offset, distance offset and distance scale are slightly larger than expected. This is felt to be due to long term variations in the scanner range, whose root cause is as of yet unidentified. Nevertheless, a temporally averaged calibration dataset for each of the scanners resulted in a 25% improvement in the 3D planar misclosure residual RMSE over the standard factory calibration model.

  14. High-accuracy local positioning network for the alignment of the Mu2e experiment.

    Energy Technology Data Exchange (ETDEWEB)

    Hejdukova, Jana B. [Czech Technical Univ., Prague (Czech Republic)

    2017-06-01

    This Diploma thesis describes the establishment of a high-precision local positioning network and accelerator alignment for the Mu2e physics experiment. The process of establishing new network consists of few steps: design of the network, pre-analysis, installation works, measurements of the network and making adjustments. Adjustments were performed using two approaches. First is a geodetic approach of taking into account the Earth’s curvature and the metrological approach of a pure 3D Cartesian system on the other side. The comparison of those two approaches is performed and evaluated in the results and compared with expected differences. The effect of the Earth’s curvature was found to be significant for this kind of network and should not be neglected. The measurements were obtained with Absolute Tracker AT401, leveling instrument Leica DNA03 and gyrotheodolite DMT Gyromat 2000. The coordinates of the points of the reference network were determined by the Least Square Meth od and the overall view is attached as Annexes.

  15. High-accuracy, high-precision, high-resolution, continuous monitoring of urban greenhouse gas emissions? Results to date from INFLUX

    Science.gov (United States)

    Davis, K. J.; Brewer, A.; Cambaliza, M. O. L.; Deng, A.; Hardesty, M.; Gurney, K. R.; Heimburger, A. M. F.; Karion, A.; Lauvaux, T.; Lopez-Coto, I.; McKain, K.; Miles, N. L.; Patarasuk, R.; Prasad, K.; Razlivanov, I. N.; Richardson, S.; Sarmiento, D. P.; Shepson, P. B.; Sweeney, C.; Turnbull, J. C.; Whetstone, J. R.; Wu, K.

    2015-12-01

    The Indianapolis Flux Experiment (INFLUX) is testing the boundaries of our ability to use atmospheric measurements to quantify urban greenhouse gas (GHG) emissions. The project brings together inventory assessments, tower-based and aircraft-based atmospheric measurements, and atmospheric modeling to provide high-accuracy, high-resolution, continuous monitoring of emissions of GHGs from the city. Results to date include a multi-year record of tower and aircraft based measurements of the urban CO2 and CH4 signal, long-term atmospheric modeling of GHG transport, and emission estimates for both CO2 and CH4 based on both tower and aircraft measurements. We will present these emissions estimates, the uncertainties in each, and our assessment of the primary needs for improvements in these emissions estimates. We will also present ongoing efforts to improve our understanding of atmospheric transport and background atmospheric GHG mole fractions, and to disaggregate GHG sources (e.g. biogenic vs. fossil fuel CO2 fluxes), topics that promise significant improvement in urban GHG emissions estimates.

  16. The Alvarado score for predicting acute appendicitis: a systematic review

    Science.gov (United States)

    2011-01-01

    Background The Alvarado score can be used to stratify patients with symptoms of suspected appendicitis; the validity of the score in certain patient groups and at different cut points is still unclear. The aim of this study was to assess the discrimination (diagnostic accuracy) and calibration performance of the Alvarado score. Methods A systematic search of validation studies in Medline, Embase, DARE and The Cochrane library was performed up to April 2011. We assessed the diagnostic accuracy of the score at the two cut-off points: score of 5 (1 to 4 vs. 5 to 10) and score of 7 (1 to 6 vs. 7 to 10). Calibration was analysed across low (1 to 4), intermediate (5 to 6) and high (7 to 10) risk strata. The analysis focused on three sub-groups: men, women and children. Results Forty-two studies were included in the review. In terms of diagnostic accuracy, the cut-point of 5 was good at 'ruling out' admission for appendicitis (sensitivity 99% overall, 96% men, 99% woman, 99% children). At the cut-point of 7, recommended for 'ruling in' appendicitis and progression to surgery, the score performed poorly in each subgroup (specificity overall 81%, men 57%, woman 73%, children 76%). The Alvarado score is well calibrated in men across all risk strata (low RR 1.06, 95% CI 0.87 to 1.28; intermediate 1.09, 0.86 to 1.37 and high 1.02, 0.97 to 1.08). The score over-predicts the probability of appendicitis in children in the intermediate and high risk groups and in women across all risk strata. Conclusions The Alvarado score is a useful diagnostic 'rule out' score at a cut point of 5 for all patient groups. The score is well calibrated in men, inconsistent in children and over-predicts the probability of appendicitis in women across all strata of risk. PMID:22204638

  17. Development of a High-fidelity Experimental Substructure Test Rig for Grid-scored Sandwich Panels in Wind Turbine Blades

    DEFF Research Database (Denmark)

    Laustsen, Steffen; Lund, Erik; Kühlmeier, L.;

    2014-01-01

    This paper outlines high-fidelity experimental substructure testing of sandwich panels which constitute the aerodynamic outer shell of modern wind turbine blades. A full-scale structural experimental and numerical characterisation of a composite wind turbine blade has been conducted. The developm...... of substructure tests for composite wind turbine blades. Furthermore, recommendations on the use of grid-scored sandwich structures in wind turbine blades are presented, which outline the sensitivity in terms of quasi-static strength to the established loading conditions.......This paper outlines high-fidelity experimental substructure testing of sandwich panels which constitute the aerodynamic outer shell of modern wind turbine blades. A full-scale structural experimental and numerical characterisation of a composite wind turbine blade has been conducted...

  18. Analysis of bromotryptophan and hydroxyproline modifications by high-resolution, high-accuracy precursor ion scanning utilizing fragment ions with mass-deficient mass tags.

    Science.gov (United States)

    Steen, Hanno; Mann, Matthias

    2002-12-15

    Protein modifications are often detected by precursor ion scanning. When quadrupole TOF mass spectrometers are used for precursor ion scanning with high-resolution, high-accuracy fragment ion selection, "reporter" ions are required to have a unique mass within +/-0.04 Da or less instead of +/-0.5 Da on triple quadrupole mass spectrometers, the traditional instrument used for precursor ion scanning. Thus, characteristic fragment ions can be utilized even if other fragment ions have the same nominal mass as long as the characteristic fragment ions are slightly mass deficient as compared to the other fragments, i.e., when they have an inherent mass-deficient mass tag. Here, the immonium ions of bromotryptophan and hydroxyproline are described as two fragment ions characteristic for tryptophan-brominated and proline-hydroxylated peptides, respectively. The "reporter" ion of trytophan-brominated peptides is highly mass deficient due to the presence of bromine, thereby allowing the selective detection of these species and the distinction from other dipeptidic a-, b-, and y-fragment ions by high-resolution, high-accuracy precursor ion scanning. This strategy also enables the differentiation between precursors giving rise to the oxygen-containing immonium ion of hydroxyproline and precursors of the immonium ions of near-ubiquitous leucine/isoleucine. Both immonium ions have the same nominal mass of 86 Da, but the exact masses differ by less than 0.04 Da. High-resolution, high-accuracy precursor ion scanning enabled the identification of proline-hydroxylated and tryptophan-brominated species and the directed analysis of species carrying these modifications in a highly complex Conus textile conotoxin mixture. This lead to the characterization of one novel C. textile conotoxin containing a bromotryptophan residue and one novel C. textile conotoxin carrying two hydroxyproline residues.

  19. Real-time integration of a tactical-grade IMU and GPS for high-accuracy positioning and navigation

    Science.gov (United States)

    Petovello, Mark G.

    2003-10-01

    The integration of the Global Positioning System (CPS) and Inertial Navigation Systems (INSs) is often used to provide accurate positioning and navigation information. For applications requiring the highest accuracy, the quality of the inertial sensors required is usually assumed to be very high. This dissertation investigates the integration of CPS with a tactical-grade Inertial Measurement Unit (IMU) for centimetre-level navigation in real-time. Different GPS/INS integration strategies are investigated to assess their relative performance in terms of position and velocity accuracy during partial and complete data outages, carrier phase ambiguity resolution after such data outages, and the overall statistical reliability of the system. In terms of statistical reliability, the traditional equations used in dynamic systems are redeveloped in light of some practical considerations, including centralized and decentralized filter architectures, and sequential versus simultaneous measurement updating. Results show that the integrated solution outperforms the GPS-only approach in all areas. The difference between loose and tight integration strategies was most significant for ambiguity resolution and system reliability. The integrated solution is capable of providing decimetre-level accuracy or better for durations of about five or ten seconds when a complete or partial CPS outage is simulated. This level of accuracy, extended over longer time intervals, is shown to reduce the time required to resolve the L1 ambiguities by an average of about 50% or more for data outages as long as 30 seconds when using a tight integration strategy. More importantly, the reliability of the ambiguity resolution process is improved with the integrated system. Statistical reliability parameters are also dramatically better when using the integrated system with the ability of detecting a single-cycle cycle slip being better and more consistent, relative to GPS-only. The effect of undetected

  20. High-energy feedback microwave thermotherapy and intraprostatic injections of mepivacaine and adrenaline: an evaluation of calculated cell kill accuracy and responder rate.

    Science.gov (United States)

    Stenmark, Fredrik; Brudin, Lars; Stranne, Johan; Peeker, Ralph

    2014-08-01

    The aim of this study was to evaluate cell kill accuracy and responder rate when using injections of intraprostatic mepivacaine and adrenaline (MA) before high-energy microwave thermotherapy (HE-TUMT). This retrospective evaluation encompassed 283 treatments in men with lower urinary tract symptoms or urinary retention due to benign prostatic hyperplasia. They were treated consecutively during 2003-2008 using HE-TUMT with a feedback technique. Immediately before treatment, MA was administered into the prostate via a Schelin Catheter®. Clinical outcome was evaluated 3 months after treatment using a validated symptom score, transrectal ultrasound, peak urinary flow and postvoid residual. Systematic underestimation of the resulting coagulation necrosis was a consistent finding when using MA, a calculated cell kill of 21% yielding a volume reduction of 26% for prostate volumes less than 100 ml and 31% for prostate volumes greater than or equal to 100 ml. Mean prostate volume was 74 ml and mean treatment time was 13 min. Less than 1% of the patients needed analgesics or sedatives on demand. Analysis of the data showed an estimated clinical responder rate of approximately 87%. The resulting prostate volume reduction corresponds to the earlier empirically recommended 30% cell kill for CoreTherm® without MA. The treatment concept combining CoreTherm with intraprostatic injections of MA corresponds to the clinical outcome of thermotherapy without MA, with the benefits of reduced pain, shortened treatment time and decreased energy consumption.

  1. A new TEC interpolation method based on the least squares collocation for high accuracy regional ionospheric maps

    Science.gov (United States)

    Krypiak-Gregorczyk, Anna; Wielgosz, Paweł; Jarmołowski, Wojciech

    2017-04-01

    The ionosphere plays a crucial role in space weather that affects satellite navigation as the ionospheric delay is one of the major errors in GNSS. On the other hand, GNSS observations are widely used to determine the amount of ionospheric total electron content (TEC). An important aspect in the electron content estimation at regional and global scale is adopting the appropriate interpolation strategy. In this paper we propose and validate a new method for regional TEC modeling based on least squares collocation (LSC) with noise variance estimation. This method allows for providing accurate TEC maps with high spatial and temporal resolution. Such maps may be used to support precise GNSS positioning and navigation, e.g. in RTK mode and also in the ionosphere studies. To test applicability of new TEC maps to positioning, double-difference ionospheric corrections were derived from the maps and their accuracy was analyzed. In addition, the corrections were applied to GNSS positioning and validated in ambiguity resolution domain. The tests were carried out during a strong ionospheric storm when the ionosphere is particularly difficult to model. The performance of the new approach was compared to IGS and UPC global, and CODE regional TEC maps. The results showed an advantage of our solution with resulting accuracy of the relative ionospheric corrections usually better than 10 cm, even during the ionospheric disturbances. This proves suitability of our regional TEC maps for, e.g. supporting fast ambiguity resolution in kinematic GNSS positioning.

  2. Interventions following a high violence risk assessment score: a naturalistic study on a Finnish psychiatric admission ward.

    Science.gov (United States)

    Kaunomäki, Jenni; Jokela, Markus; Kontio, Raija; Laiho, Tero; Sailas, Eila; Lindberg, Nina

    2017-01-11

    Patient aggression and violence against staff members and other patients are common concerns in psychiatric units. Many structured clinical risk assessment tools have recently been developed. Despite their superiority to unaided clinical judgments, staff has shown ambivalent views towards them. A constant worry of staff is that the results of risk assessments would not be used. The aims of the present study were to investigate what were the interventions applied by the staff of a psychiatric admission ward after a high risk patient had been identified, how frequently these interventions were used and how effective they were. The data were collected in a naturalistic setting during a 6-month period in a Finnish psychiatric admission ward with a total of 331 patients with a mean age of 42.9 years (SD 17.39) suffering mostly from mood, schizophrenia-related and substance use disorders. The total number of treatment days was 2399. The staff assessed the patients daily with the Dynamic Appraisal of Situational Aggression (DASA), which is a structured violence risk assessment considering the upcoming 24 h. The interventions in order to reduce the risk of violence following a high DASA total score (≥4) were collected from the patients' medical files. Inductive content analysis was used. There were a total of 64 patients with 217 observations of high DASA total score. In 91.2% of cases, at least one intervention aiming to reduce the violence risk was used. Pro re nata (PRN)-medication, seclusion and focused discussions with a nurse were the most frequently used interventions. Non-coercive and non-pharmacological interventions like daily activities associated significantly with the decrease of perceived risk of violence. In most cases, a high score in violence risk assessment led to interventions aiming to reduce the risk. Unfortunately, the most frequently used methods were psychopharmacological or coercive. It is hoped that the findings will encourage the staff to use

  3. Location accuracy evaluation of lightning location systems using natural lightning flashes recorded by a network of high-speed cameras

    Science.gov (United States)

    Alves, J.; Saraiva, A. C. V.; Campos, L. Z. D. S.; Pinto, O., Jr.; Antunes, L.

    2014-12-01

    This work presents a method for the evaluation of location accuracy of all Lightning Location System (LLS) in operation in southeastern Brazil, using natural cloud-to-ground (CG) lightning flashes. This can be done through a multiple high-speed cameras network (RAMMER network) installed in the Paraiba Valley region - SP - Brazil. The RAMMER network (Automated Multi-camera Network for Monitoring and Study of Lightning) is composed by four high-speed cameras operating at 2,500 frames per second. Three stationary black-and-white (B&W) cameras were situated in the cities of São José dos Campos and Caçapava. A fourth color camera was mobile (installed in a car), but operated in a fixed location during the observation period, within the city of São José dos Campos. The average distance among cameras was 13 kilometers. Each RAMMER sensor position was determined so that the network can observe the same lightning flash from different angles and all recorded videos were GPS (Global Position System) time stamped, allowing comparisons of events between cameras and the LLS. The RAMMER sensor is basically composed by a computer, a Phantom high-speed camera version 9.1 and a GPS unit. The lightning cases analyzed in the present work were observed by at least two cameras, their position was visually triangulated and the results compared with BrasilDAT network, during the summer seasons of 2011/2012 and 2012/2013. The visual triangulation method is presented in details. The calibration procedure showed an accuracy of 9 meters between the accurate GPS position of the object triangulated and the result from the visual triangulation method. Lightning return stroke positions, estimated with the visual triangulation method, were compared with LLS locations. Differences between solutions were not greater than 1.8 km.

  4. Norm-Referenced Cognitive and Achievement Scores as Predictors of State-Wide High-Stakes Test Scores with Students Referred for Special Education

    Science.gov (United States)

    Trinkle, James M., II

    2013-01-01

    Relatively recent federal education initiatives, such as No Child Left Behind (NCLB; 2001), have focused on school accountability for student achievement including achievement of traditionally at-risk populations, such as students in special education, students from low-income or high poverty areas, and students who speak English as a new second…

  5. Static Calibration and Analysis of the Velodyne HDL-64E S2 for High Accuracy Mobile Scanning

    Directory of Open Access Journals (Sweden)

    Craig Glennie

    2010-06-01

    Full Text Available The static calibration and analysis of the Velodyne HDL-64E S2 scanning LiDAR system is presented and analyzed. The mathematical model for measurements for the HDL-64E S2 scanner is derived and discussed. A planar feature based least squares adjustment approach is presented and utilized in a minimally constrained network in order to derive an optimal solution for the laser’s internal calibration parameters. Finally, the results of the adjustment along with a detailed examination of the adjustment residuals are given. A three-fold improvement in the planar misclosure residual RMSE over the standard factory calibration model was achieved by the proposed calibration. Results also suggest that there may still be some unmodelled distortions in the range measurements from the scanner. However, despite this, the overall precision of the adjusted laser scanner data appears to make it a viable choice for high accuracy mobile scanning applications.

  6. High-accuracy measurements of snow Bidirectional Reflectance Distribution Function at visible and NIR wavelengths – comparison with modelling results

    Directory of Open Access Journals (Sweden)

    Y. Arnaud

    2009-09-01

    Full Text Available High-accuracy measurements of snow Bidirectional Reflectance Distribution Function (BRDF were performed for four natural snow samples with a spectrogonio-radiometer in the 500–2600 nm wavelength range. These measurements are one of the first set of direct snow BRDF values over a wide range of lighting and viewing geometry. They were compared to BRDF calculated with two optical models. Variations of the snow anisotropy factor with lighting geometry, wavelength and snow physical properties were investigated. Results show that at wavelengths with small penetration depth, scattering mainly occurs in the very top layers and the anisotropy factor is controlled by the phase function. In this condition, forward scattering peak or double scattering peak is observed. In constrast at shorter wavelengths, the penetration of the radiation is much deeper and the number of scattering events increases. The anisotropy factor is thus nearly constant and decreases at grazing observation angles.

  7. High-accuracy measurements of snow Bidirectional Reflectance Distribution Function at visible and NIR wavelengths - comparison with modelling results

    Science.gov (United States)

    Dumont, M.; Brissaud, O.; Picard, G.; Schmitt, B.; Gallet, J.-C.; Arnaud, Y.

    2010-03-01

    High-accuracy measurements of snow Bidirectional Reflectance Distribution Function (BRDF) were performed for four natural snow samples with a spectrogonio-radiometer in the 500-2600 nm wavelength range. These measurements are one of the first sets of direct snow BRDF values over a wide range of lighting and viewing geometry. They were compared to BRDF calculated with two optical models. Variations of the snow anisotropy factor with lighting geometry, wavelength and snow physical properties were investigated. Results show that at wavelengths with small penetration depth, scattering mainly occurs in the very top layers and the anisotropy factor is controlled by the phase function. In this condition, forward scattering peak or double scattering peak is observed. In contrast at shorter wavelengths, the penetration of the radiation is much deeper and the number of scattering events increases. The anisotropy factor is thus nearly constant and decreases at grazing observation angles. The whole dataset is available on demand from the corresponding author.

  8. Fundamental M-dwarf parameters from high-resolution spectra using PHOENIX ACES models: I. Parameter accuracy and benchmark stars

    CERN Document Server

    Passegger, Vera Maria; Reiners, Ansgar

    2016-01-01

    M-dwarf stars are the most numerous stars in the Universe; they span a wide range in mass and are in the focus of ongoing and planned exoplanet surveys. To investigate and understand their physical nature, detailed spectral information and accurate stellar models are needed. We use a new synthetic atmosphere model generation and compare model spectra to observations. To test the model accuracy, we compared the models to four benchmark stars with atmospheric parameters for which independent information from interferometric radius measurements is available. We used $\\chi^2$ -based methods to determine parameters from high-resolution spectroscopic observations. Our synthetic spectra are based on the new PHOENIX grid that uses the ACES description for the equation of state. This is a model generation expected to be especially suitable for the low-temperature atmospheres. We identified suitable spectral tracers of atmospheric parameters and determined the uncertainties in $T_{\\rm eff}$, $\\log{g}$, and [Fe/H] resul...

  9. Prognostic Value Of Normal Myocardial Perfusion Imaging In Asymptomatic Diabetic Patients With Moderate And High Calcium Scores

    Directory of Open Access Journals (Sweden)

    Mitevska Irena Peovska

    2015-06-01

    Full Text Available The purpose of this study was to evaluate the intermediate prognostic value of normal myocardial perfusion imaging (MPI in asymptomatic diabetic patients with intermediate and high coronary artery calcium (CAC scores. Methods: A total of 115 asymptomatic diabetic patients with no known coronary artery disease (CAD underwent MPI after multi-slice computed tomography CAC assessment for the detection of suspected CAD. The study included 75 patients with normal MPI results. A 17-segment model for myocardial perfusion and function analysis was used. Patients were divided into three groups: I gr-20 patients with a diabetes duration between 1-5 years; II gr-24 patients with a diabetes duration 5-10 years; and III gr-31 patients with a diabetes duration >10 years. End points (cardiac death, non-fatal myocardial infarction, heart failure, new angina, revascularization were assessed at 6, 12 and 24 months.

  10. High prevalence of methotrexate intolerance in juvenile idiopathic arthritis: development and validation of a methotrexate intolerance severity score.

    Science.gov (United States)

    Bulatović, Maja; Heijstek, Marloes W; Verkaaik, Marleen; van Dijkhuizen, E H Pieter; Armbrust, Wineke; Hoppenreijs, Esther P A; Kamphuis, Sylvia; Kuis, Wietse; Egberts, Toine C G; Sinnema, Gerben; Rademaker, Carin M A; Wulffraat, Nico M

    2011-07-01

    To design and validate a new questionnaire for identifying patients with methotrexate (MTX) intolerance, and to determine the prevalence of MTX intolerance in patients with juvenile idiopathic arthritis (JIA) using this questionnaire. The MTX Intolerance Severity Score (MISS) questionnaire was constructed, consisting of 5 domains: stomach ache, nausea, vomiting, sore mouth, and behavioral symptoms. The domains each consisted of 3 questions pertaining to the presence of a symptom upon, prior to (anticipatory), and when thinking of (associative) MTX intake. The MISS questionnaire was validated in 86 patients by determining its discriminative power between patients with and those without MTX intolerance, identified as such by a gold standard (physician's opinion). Using the MISS questionnaire, the prevalence of MTX intolerance was determined in 297 JIA patients. The MISS questionnaire discriminated well between MTX-intolerant and MTX-tolerant patients. A cutoff score of 6 yielded the best sensitivity (88%) and specificity (80%). MTX intolerance was found in 150 (50.5%) of 297 patients. Of 220 patients receiving oral MTX, 98 (44.5%) experienced MTX intolerance, whereas 67.5% of 77 patients receiving parenteral MTX experienced intolerance to the drug (P = 0.001). Our findings indicate that the MISS questionnaire is a highly sensitive and specific tool for the diagnosis of MTX intolerance, and that there is a high prevalence of MTX intolerance among JIA patients. The prevalence of intolerance in patients receiving parenteral MTX exceeds that in patients receiving oral MTX. The frequent occurrence of anticipatory and associative symptoms suggests that classic conditioning plays an important role in MTX intolerance. Copyright © 2011 by the American College of Rheumatology.

  11. Novel technique to suppress hydrocarbon contamination for high accuracy determination of carbon content in steel by FE-EPMA

    Science.gov (United States)

    Yamashita, Takako; Tanaka, Yuji; Yagoshi, Masayasu; Ishida, Kiyohito

    2016-07-01

    In multiphase steels, control of the carbon contents in the respective phases is the most important factor in alloy design for achieving high strength and high ductility. However, it is unusually difficult to determine the carbon contents in multiphase structures with high accuracy by electron probe microanalysis (EPMA) due to the unavoidable effect of hydrocarbon contamination during measurements. We have investigated new methods for suppressing hydrocarbon contamination during field emission (FE) EPMA measurements as well as a conventional liquid nitrogen trap. Plasma cleaner inside the specimen chamber results in a improvement of carbon-content determination by point analysis, increasing precision tenfold from the previous 0.1 mass%C to 0.01 mass%C. Stage heating at about 100 °C dramatically suppresses contamination growth during continuous point measurement and mapping. By the combination of above two techniques, we successfully visualized the two-dimensional carbon distribution in a dual-phase steel. It was also noted that the carbon concentrations at the ferrite/martensite interfaces were not the same across all interfaces, and local variation was observed. The developed technique is expected to be a powerful tool for understanding the mechanisms of mechanical properties and microstructural evolution, thereby contributing to the design of new steel products with superior properties.

  12. High-Accuracy Tidal Flat Digital Elevation Model Construction Using TanDEM-X Science Phase Data

    Science.gov (United States)

    Lee, Seung-Kuk; Ryu, Joo-Hyung

    2017-01-01

    This study explored the feasibility of using TanDEM-X (TDX) interferometric observations of tidal flats for digital elevation model (DEM) construction. Our goal was to generate high-precision DEMs in tidal flat areas, because accurate intertidal zone data are essential for monitoring coastal environment sand erosion processes. To monitor dynamic coastal changes caused by waves, currents, and tides, very accurate DEMs with high spatial resolution are required. The bi- and monostatic modes of the TDX interferometer employed during the TDX science phase provided a great opportunity for highly accurate intertidal DEM construction using radar interferometry with no time lag (bistatic mode) or an approximately 10-s temporal baseline (monostatic mode) between the master and slave synthetic aperture radar image acquisitions. In this study, DEM construction in tidal flat areas was first optimized based on the TDX system parameters used in various TDX modes. We successfully generated intertidal zone DEMs with 57-m spatial resolutions and interferometric height accuracies better than 0.15 m for three representative tidal flats on the west coast of the Korean Peninsula. Finally, we validated these TDX DEMs against real-time kinematic-GPS measurements acquired in two tidal flat areas; the correlation coefficient was 0.97 with a root mean square error of 0.20 m.

  13. Novel technique to suppress hydrocarbon contamination for high accuracy determination of carbon content in steel by FE-EPMA.

    Science.gov (United States)

    Yamashita, Takako; Tanaka, Yuji; Yagoshi, Masayasu; Ishida, Kiyohito

    2016-07-19

    In multiphase steels, control of the carbon contents in the respective phases is the most important factor in alloy design for achieving high strength and high ductility. However, it is unusually difficult to determine the carbon contents in multiphase structures with high accuracy by electron probe microanalysis (EPMA) due to the unavoidable effect of hydrocarbon contamination during measurements. We have investigated new methods for suppressing hydrocarbon contamination during field emission (FE) EPMA measurements as well as a conventional liquid nitrogen trap. Plasma cleaner inside the specimen chamber results in a improvement of carbon-content determination by point analysis, increasing precision tenfold from the previous 0.1 mass%C to 0.01 mass%C. Stage heating at about 100 °C dramatically suppresses contamination growth during continuous point measurement and mapping. By the combination of above two techniques, we successfully visualized the two-dimensional carbon distribution in a dual-phase steel. It was also noted that the carbon concentrations at the ferrite/martensite interfaces were not the same across all interfaces, and local variation was observed. The developed technique is expected to be a powerful tool for understanding the mechanisms of mechanical properties and microstructural evolution, thereby contributing to the design of new steel products with superior properties.

  14. Association between scores in high school, aptitude and achievement exams and early performance in health science college

    Directory of Open Access Journals (Sweden)

    Al-Alwan Ibrahim

    2009-01-01

    Full Text Available This retrospective study was carried out to assess the correlation between admi-ssion criteria to health science colleges, namely, final high school grade and Saudi National Apti-tude and Achievement exams, and early academic performance in these colleges. The study inclu-ded 91 male students studying in the two-year pre-professional program at the King Saud bin Abdulaziz University for Health Sciences (KSAU-HS, Riyadh, Saudi Arabia. Records of these students were used to extract relevant information and their academic performance (based on the grade point average achieved at the end of the first semester of the pre-professional program, which were analytically studied. Pearson correlation coefficient was used to assess the associa-tions between the different scores. SPSS statistical program (version 12.0 was used for data ana-lyses. We found a strong correlation between the academic performance and the Achievement Exam, Aptitude Exam and high school final grade, with Pearson Correlation Coefficients of 0.96, 0.93, 0.87, respectively. The Saudi National Achievement Exam showed the most significant correla-tion. Our results indicate that academic performance showed good correlation with the admission criteria used, namely final high school grade, Saudi National Aptitude and Achievement Exams.

  15. Characterization of an experimental arrangement to measure position of particles in 3D with a high accuracy

    Science.gov (United States)

    Martínez González, A.; Guerrero Viramontes, J. A.; Moreno Hernández, D.

    2011-09-01

    Single particle position calculation in three dimensions (3D) with high accuracy is the very important in several branches of science. On the other hand, the use of in-line holography to study very small objects in a dynamic volume is a technique of importance for scientists and engineers across a variety of disciplines for obtaining information about size, shape, trajectory and velocity of small objects such as dust particles. However, in general for in-line holography, accurate determination of the object's position in the optical axis direction is difficult. In order to overcome this shortcoming, we proposed to use in-line holography set up to record particle images in two orthogonal forward configurations. In this study, we avoid digital holography reconstruction to calculate particle position. To determine particle position, the proposed method is based on the calculation of the size and position of the central spot size (CSS) of a particle diffraction image. The size of the CSS is calculated by using the Continuous Wavelet Transform (CWT) and Continuous Hough Transforms (CHT), an then the size of the CSS is related to a calibration curve calculated experimentally in order to determine the "z" particle position and centroid of the CSS render the "x-y" position of a particle image. The procedure proposed in this work to determine the 3D particle position is so simple since it avoids a complicated experimental set-up and several computational steps in order to obtain the 3D position of the particles. Our approach offers the following advantages: First, the mathematical accuracy, light illumination as well as particle and medium refractive indexes are used during the analysis. Second, it is not required to resolve the size of particle since we calculate only the size of CSS of a diffraction particle image pattern.

  16. Optimization and design of inter-stage amplifier with wide output swing,high speed and high accuracy

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yi-qiang; SUN Quan; GAO Jing

    2008-01-01

    To satisfy the design requirements of analog-to-digital converter (ADC) of high speed sampling sys-tem in an infrared focal plane array tester with 1024 × 1024 pixels, a first inter-stage amplifier of 12-bit 40-Msample/s pipelined ADC was designed with 0.35 μm CMOS technology. On the basis of traditional two-stage amplifier, the cross-coupled class AB output stage and cascode compensation were adopted to improve the out-put voltage swing and bandwidth. Power dissipation was optimized with math tools. Circuit and layout design were completed. Simulation results show that the designed amplifier has good performance of 95 dB de gain, ±2 V output voltage swing, 190 MHz bandwidth and 63° phase margin with feedback factor 1/4, 33 mW pow-er dissipation and so on, which can meet the system requirements.

  17. Caspofungin versus fluconazole as prophylaxis of invasive fungal infection in high-risk liver transplantation recipients: A propensity score analysis.

    Science.gov (United States)

    Fortún, Jesús; Muriel, Alfonso; Martín-Dávila, Pilar; Montejo, Miguel; Len, Oscar; Torre-Cisneros, Julian; Carratalá, Jordi; Muñoz, Patricia; Fariñas, Carmen; Moreno, Asunción; Fresco, Gema; Goikoetxea, Josune; Gavaldá, Joan; Pozo, Juan Carlos; Bodro, Marta; Vena, Antonio; Casafont, Fernando; Cervera, Carlos; Silva, José Tiago; Aguado, José M

    2016-04-01

    Targeted prophylaxis has proven to be an efficient strategy in liver transplantation recipients (LTRs). The aim of this study was to compare the effectiveness and safety of caspofungin with that of fluconazole in high-risk (HR) LTRs. Caspofungin and fluconazole were compared in a multicenter, retrospective, cohort study in HR-LTRs in Spain. Outcomes were assessed at 180 days after transplantation. A propensity score approach was applied. During the study period (2005-2012), we analyzed 195 HR-LTRs from 9 hospitals. By type of prophylaxis, 97 patients received caspofungin and 98 received fluconazole. Of a total of 17 (8.7%) global invasive fungal infections (IFIs), breakthrough IFIs accounted for 11 (5.6%) and invasive aspergillosis (IA) accounted for 6 (3.1%). By univariate analysis, no differences were observed in the prevention of global IFIs. However, caspofungin was associated with a significant reduction in the rate of breakthrough IFIs (2.1% versus 9.2%, P = 0.04). In patients requiring dialysis (n = 62), caspofungin significantly reduced the frequency of breakthrough IFIs (P = 0.03). The propensity score analysis confirmed a significant reduction in the frequency of IA in patients receiving caspofungin (absolute risk reduction, 0.06; 95% confidence interval [CI], 0.001-0.11; P = 0.044). Linear regression analysis revealed a significant decrease in blood alanine aminotransferase levels and a significant increase in bilirubin levels after administration of caspofungin. Caspofungin and fluconazole have similar efficacy for the prevention of global IFIs in HR-LTRs in this observational, multicenter cohort study. However, caspofungin was associated with a significant reduction of breakthrough IFIs and, after adjusting for confounders, caspofungin was associated with a lower rate of IA. This benefit is probably more favorable in patients on dialysis. Caspofungin is safe in HR-LTRs, although bilirubin levels may be increased.

  18. Establishment of a scoring system for predicting the difficulty level of high-intensity focussed ultrasound ablation of uterine fibroids.

    Science.gov (United States)

    Liu, Zhongqiong; Gong, Chunmei; Liu, Yunchang; Zhang, Lian

    2017-05-19

    To establish a scoring system that predicts the difficulty level of high-intensity focussed ultrasound (HIFU) ablation of uterine fibroids. Four hundred and twenty-two patients with fibroids were enrolled. The energy efficiency factor (EEF) and sonication time were set as dependent variables, with factors possibly affecting EEF and sonication time including age, body mass index (BMI), the volume of fibroids, the location of the uterus, the type of fibroids, the signal intensity on the T2-weighted imaging (T2WI), the enhancement type, the thickness of the rectus abdominis and the subcutaneous fat layer, the distance from the anterior/posterior surface of the fibroid to the skin, and the abdominal wall scars were set as predictors for building optimal scaling regression models. The volume of the fibroids, the location of the uterus, the signal intensity on T2WI, enhancement type, rectus abdominis thickness, subcutaneous fat thickness, and distance from the anterior surface of fibroid to the skin were related to EEF. Signal intensity on T2WI, the volume of fibroids, distance from the posterior surface of fibroid to the skin, and enhancement type were related to sonication time. Models that can predict the difficulty level of HIFU for fibroids have been established: for EEF, y ' = 0.338X '1 - 0.231X '2+0.156X '3+0.167X '4 ; for sonication time, y = 0.227X1+0.321X2+0.157X3+0.194X4. A scoring system for predicting the difficulty level of HIFU treatment for uterine fibroids has been established and it can be used to help select patients and to predict the sonication time for a given fibroid.

  19. Comparison of the temperature accuracy between smart phone based and high-end thermal cameras using a temperature gradient phantom

    Science.gov (United States)

    Klaessens, John H.; van der Veen, Albert; Verdaasdonk, Rudolf M.

    2017-03-01

    Recently, low cost smart phone based thermal cameras are being considered to be used in a clinical setting for monitoring physiological temperature responses such as: body temperature change, local inflammations, perfusion changes or (burn) wound healing. These thermal cameras contain uncooled micro-bolometers with an internal calibration check and have a temperature resolution of 0.1 degree. For clinical applications a fast quality measurement before use is required (absolute temperature check) and quality control (stability, repeatability, absolute temperature, absolute temperature differences) should be performed regularly. Therefore, a calibrated temperature phantom has been developed based on thermistor heating on both ends of a black coated metal strip to create a controllable temperature gradient from room temperature 26 °C up to 100 °C. The absolute temperatures on the strip are determined with software controlled 5 PT-1000 sensors using lookup tables. In this study 3 FLIR-ONE cameras and one high end camera were checked with this temperature phantom. The results show a relative good agreement between both low-cost and high-end camera's and the phantom temperature gradient, with temperature differences of 1 degree up to 6 degrees between the camera's and the phantom. The measurements were repeated as to absolute temperature and temperature stability over the sensor area. Both low-cost and high-end thermal cameras measured relative temperature changes with high accuracy and absolute temperatures with constant deviations. Low-cost smart phone based thermal cameras can be a good alternative to high-end thermal cameras for routine clinical measurements, appropriate to the research question, providing regular calibration checks for quality control.

  20. Precision of high-resolution multibeam echo sounding coupled with high-accuracy positioning in a shallow water coastal environment

    Science.gov (United States)

    Ernstsen, Verner B.; Noormets, Riko; Hebbeln, Dierk; Bartholomä, Alex; Flemming, Burg W.

    2006-09-01

    Over 4 years, repetitive bathymetric measurements of a shipwreck in the Grådyb tidal inlet channel in the Danish Wadden Sea were carried out using a state-of-the-art high-resolution multibeam echosounder (MBES) coupled with a real-time long range kinematic (LRK™) global positioning system. Seven measurements during a single survey in 2003 ( n=7) revealed a horizontal and vertical precision of the MBES system of ±20 and ±2 cm, respectively, at a 95% confidence level. By contrast, four annual surveys from 2002 to 2005 ( n=4) yielded a horizontal and vertical precision (at 95% confidence level) of only ±30 and ±8 cm, respectively. This difference in precision can be explained by three main factors: (1) the dismounting of the system between the annual surveys, (2) rougher sea conditions during the survey in 2004 and (3) the limited number of annual surveys. In general, the precision achieved here did not correspond to the full potential of the MBES system, as this could certainly have been improved by an increase in coverage density (soundings/m2), achievable by reducing the survey speed of the vessel. Nevertheless, precision was higher than that reported to date for earlier offshore test surveys using comparable equipment.

  1. First results using a new technology for measuring masses of very short-lived nuclides with very high accuracy the MISTRAL program at ISOLDE

    CERN Document Server

    Monsanglant, C; Audi, G; Bollen, G; Borcea, C; Conreur, G; Cousin, R; Doubre, H; Duma, M; Jacotin, M; Henry, S; Képinski, J F; Kluge, H J; Lebée, G; Le Scornet, G; Lunney, S; De Saint-Simon, M; Scheidenberger, C; Thibault, C

    1999-01-01

    MISTRAL is an experimental program to measure masses of very short- lived nuclides (T$_{1/2}$ down to a few ms), with a very high accuracy (a few 10$^{-7}$). There were three data taking periods with radioactive beams and 22 masses of isotopes of Ne, Na*, Mg, Al*, K, Ca, and Ti were measured. The systematic errors are now under control at the level of 8$\\TIMES10^{-7}$, allowing to come close to the expected accuracy. Even for the very weakly produced $^{30}$Na (1 ion at the detector per proton burst), the final accuracy is 7$\\TIMES10^{-7}$. (15 refs).

  2. Parallel High Order Accuracy Methods Applied to Non-Linear Hyperbolic Equations and to Problems in Materials Sciences

    Energy Technology Data Exchange (ETDEWEB)

    Jan Hesthaven

    2012-02-06

    Final report for DOE Contract DE-FG02-98ER25346 entitled Parallel High Order Accuracy Methods Applied to Non-Linear Hyperbolic Equations and to Problems in Materials Sciences. Principal Investigator Jan S. Hesthaven Division of Applied Mathematics Brown University, Box F Providence, RI 02912 Jan.Hesthaven@Brown.edu February 6, 2012 Note: This grant was originally awarded to Professor David Gottlieb and the majority of the work envisioned reflects his original ideas. However, when Prof Gottlieb passed away in December 2008, Professor Hesthaven took over as PI to ensure proper mentoring of students and postdoctoral researchers already involved in the project. This unusual circumstance has naturally impacted the project and its timeline. However, as the report reflects, the planned work has been accomplished and some activities beyond the original scope have been pursued with success. Project overview and main results The effort in this project focuses on the development of high order accurate computational methods for the solution of hyperbolic equations with application to problems with strong shocks. While the methods are general, emphasis is on applications to gas dynamics with strong shocks.

  3. High sensitivity and accuracy dissolved oxygen (DO) detection by using PtOEP/poly(MMA-co-TFEMA) sensing film

    Science.gov (United States)

    Zhang, Ke; Zhang, Honglin; Wang, Ying; Tian, Yanqing; Zhao, Jiupeng; Li, Yao

    2017-01-01

    Fluorinated acrylate polymer has received great interest in recent years due to its extraordinary characteristics such as high oxygen permeability, good stability, low surface energy and refractive index. In this work, platinum octaethylporphyrin/poly(methylmethacrylate-co-trifluoroethyl methacrylate) (PtOEP/poly(MMA-co-TFEMA)) oxygen sensing film was prepared by the immobilizing of PtOEP in a poly(MMA-co-TFEMA) matrix and the technological readiness of optical properties was established based on the principle of luminescence quenching. It was found that the oxygen-sensing performance could be improved by optimizing the monomer ratio (MMA/TFEMA = 1:1), tributylphosphate(TBP, 0.05 mL) and PtOEP (5 μg) content. Under this condition, the maximum quenching ratio I0/I100 of the oxygen sensing film is obtained to be about 8.16, Stern-Volmer equation is I0/I = 1.003 + 2.663[O2] (R2 = 0.999), exhibiting a linear relationship, good photo-stability, high sensitivity and accuracy. Finally, the synthesized PtOEP/poly(MMA-co-TFEMA) sensing film was used for DO detection in different water samples.

  4. Score Correlation

    OpenAIRE

    Fabián, Z. (Zdeněk)

    2010-01-01

    In this paper, we study a distribution-dependent correlation coefficient based on the concept of scalar score. This new measure of association of continuous random variables is compared by means of simulation experiments with the Pearson, Kendall and Spearman correlation coefficients.

  5. Emergence of realism: Enhanced visual artistry and high accuracy of visual numerosity representation after left prefrontal damage.

    Science.gov (United States)

    Takahata, Keisuke; Saito, Fumie; Muramatsu, Taro; Yamada, Makiko; Shirahase, Joichiro; Tabuchi, Hajime; Suhara, Tetsuya; Mimura, Masaru; Kato, Motoichiro

    2014-05-01

    Over the last two decades, evidence of enhancement of drawing and painting skills due to focal prefrontal damage has accumulated. It is of special interest that most artworks created by such patients were highly realistic ones, but the mechanism underlying this phenomenon remains to be understood. Our hypothesis is that enhanced tendency of realism was associated with accuracy of visual numerosity representation, which has been shown to be mediated predominantly by right parietal functions. Here, we report a case of left prefrontal stroke, where the patient showed enhancement of artistic skills of realistic painting after the onset of brain damage. We investigated cognitive, functional and esthetic characteristics of the patient׳s visual artistry and visual numerosity representation. Neuropsychological tests revealed impaired executive function after the stroke. Despite that, the patient׳s visual artistry related to realism was rather promoted across the onset of brain damage as demonstrated by blind evaluation of the paintings by professional art reviewers. On visual numerical cognition tasks, the patient showed higher performance in comparison with age-matched healthy controls. These results paralleled increased perfusion in the right parietal cortex including the precuneus and intraparietal sulcus. Our data provide new insight into mechanisms underlying change in artistic style due to focal prefrontal lesion.

  6. High-accuracy diagnostic tool for electron cloud observation in the LHC based on synchronous phase measurements

    Science.gov (United States)

    Esteban Müller, J. F.; Baudrenghien, P.; Mastoridis, T.; Shaposhnikova, E.; Valuch, D.

    2015-11-01

    Electron cloud effects, which include heat load in the cryogenic system, pressure rise, and beam instabilities, are among the main intensity limitations for the LHC operation with 25 ns spaced bunches. A new observation tool was proposed and developed to monitor the e-cloud activity and it has already been used successfully during the LHC run 1 (2010-2012) and it is being intensively used in operation during the start of the LHC run 2 (2015-2018). It is based on the fact that the power loss of each bunch due to e-cloud can be estimated using bunch-by-bunch measurement of the synchronous phase. The measurements were done using the existing beam phase module of the low-level rf control system. In order to achieve the very high accuracy required, corrections for reflection in the cables and for systematic errors need to be applied followed by a post-processing of the measurements. Results clearly show the e-cloud buildup along the bunch trains and its time evolution during each LHC fill as well as from fill to fill. Measurements during the 2012 LHC scrubbing run reveal a progressive reduction in the e-cloud activity and therefore a decrease in the secondary electron yield. The total beam power loss can be computed as a sum of the contributions from all bunches and compared with the heat load deposited in the cryogenic system.

  7. High Accuracy Potential Energy Surface, Dipole Moment Surface, Rovibrational Energies and Line List Calculations for ^{14}NH_3

    Science.gov (United States)

    Coles, Phillip; Yurchenko, Sergei N.; Polyansky, Oleg; Kyuberis, Aleksandra; Ovsyannikov, Roman I.; Zobov, Nikolay Fedorovich; Tennyson, Jonathan

    2017-06-01

    We present a new spectroscopic potential energy surface (PES) for ^{14}NH_3, produced by refining a high accuracy ab initio PES to experimental energy levels taken predominantly from MARVEL. The PES reproduces 1722 matched J=0-8 experimental energies with a root-mean-square error of 0.035 cm-1 under 6000 cm^{-1} and 0.059 under 7200 cm^{-1}. In conjunction with a new DMS calculated using multi reference configuration interaction (MRCI) and H=aug-cc-pVQZ, N=aug-cc-pWCVQZ basis sets, an infrared (IR) line list has been computed which is suitable for use up to 2000 K. The line list is used to assign experimental lines in the 7500 - 10,500 cm^{-1} region and previously unassigned lines in HITRAN in the 6000-7000 cm^{-1} region. Oleg L. Polyansky, Roman I. Ovsyannikov, Aleksandra A. Kyuberis, Lorenzo Lodi, Jonathan Tennyson, Andrey Yachmenev, Sergei N. Yurchenko, Nikolai F. Zobov, J. Mol. Spec., 327 (2016) 21-30 Afaf R. Al Derzia, Tibor Furtenbacher, Jonathan Tennyson, Sergei N. Yurchenko, Attila G. Császár, J. Quant. Spectrosc. Rad. Trans., 161 (2015) 117-130

  8. High-accuracy measurements of snow Bidirectional Reflectance Distribution Function at visible and NIR wavelengths – comparison with modelling results

    Directory of Open Access Journals (Sweden)

    M. Dumont

    2010-03-01

    Full Text Available High-accuracy measurements of snow Bidirectional Reflectance Distribution Function (BRDF were performed for four natural snow samples with a spectrogonio-radiometer in the 500–2600 nm wavelength range. These measurements are one of the first sets of direct snow BRDF values over a wide range of lighting and viewing geometry. They were compared to BRDF calculated with two optical models. Variations of the snow anisotropy factor with lighting geometry, wavelength and snow physical properties were investigated. Results show that at wavelengths with small penetration depth, scattering mainly occurs in the very top layers and the anisotropy factor is controlled by the phase function. In this condition, forward scattering peak or double scattering peak is observed. In contrast at shorter wavelengths, the penetration of the radiation is much deeper and the number of scattering events increases. The anisotropy factor is thus nearly constant and decreases at grazing observation angles. The whole dataset is available on demand from the corresponding author.

  9. The LLNL High Accuracy Volume Renderer for Unstructured Data: Capabilities, Current Limits, and Potential for ASCI/VIEWS Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Williams, P L; Max, N L

    2001-06-04

    This report describes a volume rendering system for unstructured data, especially finite element data, that creates images with very high accuracy. The system will currently handle meshes whose cells are either linear or quadratic tetrahedra, or meshes with mixed cell types: tetrahedra, bricks, prisms, and pyramids. The cells may have nonplanar facets. Whenever possible, exact mathematical solutions for the radiance integrals and for interpolation are used. Accurate semitransparent shaded isosurfaces may be embedded in the volume rendering. For very small cells, subpixel accumulation by splatting is used to avoid sampling error. A new exact and efficient visibility ordering algorithm is described. The most accurate images are generated in software, however, more efficient algorithms utilizing graphics hardware may also be selected. The report describes the parallelization of the system for a distributed-shared memory multiprocessor machine, and concludes by discussing the system's limits, desirable future work, and ways to extend the system so as to be compatible with projected ASCI/VIEWS architectures.

  10. Estimating subsurface water volumes and transit times in Hokkaido river catchments, Japan, using high-accuracy tritium analysis

    Science.gov (United States)

    Gusyev, Maksym; Yamazaki, Yusuke; Morgenstern, Uwe; Stewart, Mike; Kashiwaya, Kazuhisa; Hirai, Yasuyuki; Kuribayashi, Daisuke; Sawano, Hisaya

    2015-04-01

    The goal of this study is to estimate subsurface water transit times and volumes in headwater catchments of Hokkaido, Japan, using the New Zealand high-accuracy tritium analysis technique. Transit time provides insights into the subsurface water storage and therefore provides a robust and quick approach to quantifying the subsurface groundwater volume. Our method is based on tritium measurements in river water. Tritium is a component of meteoric water, decays with a half-life of 12.32 years, and is inert in the subsurface after the water enters the groundwater system. Therefore, tritium is ideally suited for characterization of the catchment's responses and can provide information on mean water transit times up to 200 years. Only in recent years has it become possible to use tritium for dating of stream and river water, due to the fading impact of the bomb-tritium from thermo-nuclear weapons testing, and due to improved measurement accuracy for the extremely low natural tritium concentrations. Transit time of the water discharge is one of the most crucial parameters for understanding the response of catchments and estimating subsurface water volume. While many tritium transit time studies have been conducted in New Zealand, only a limited number of tritium studies have been conducted in Japan. In addition, the meteorological, orographic and geological conditions of Hokkaido Island are similar to those in parts of New Zealand, allowing for comparison between these regions. In 2014, three field trips were conducted in Hokkaido in June, July and October to sample river water at river gauging stations operated by the Ministry of Land, Infrastructure, Transport and Tourism (MLIT). These stations have altitudes between 36 m and 860 m MSL and drainage areas between 45 and 377 km2. Each sampled point is located upstream of MLIT dams, with hourly measurements of precipitation and river water levels enabling us to distinguish between the snow melt and baseflow contributions

  11. Experienced and inexperienced observers achieved relatively high within-observer agreement on video mobility scoring of dairy cows

    DEFF Research Database (Denmark)

    Garcia, Emanuel; König, Kamilla; Allesen-Holm, Bodil Helene;

    2015-01-01

    Gait scoring of individual cows is essential for health and welfare assessments, including detection of decreased mobility over time. Meaningful comparison of the cows’ gait requires observers who are able to score the same cow equally under the same conditions, at two distinct time-points (within-observer...... agreement). A total of 102 observers, including cattle-experienced and inexperienced, scored 22 videos in replicates (with five gait types). The probability of perfect agreement ranged from 45% to 90% when considering the effect of gait type. Observers without prior experience obtained up to 60% perfect...... agreement, which made them closely on pair with experienced observers....

  12. Diagnostic accuracy of GPs when using an early-intervention decision support system: a high-fidelity simulation

    Science.gov (United States)

    Kostopoulou, Olga; Porat, Talya; Corrigan, Derek; Mahmoud, Samhar; Delaney, Brendan C

    2017-01-01

    Background Observational and experimental studies of the diagnostic task have demonstrated the importance of the first hypotheses that come to mind for accurate diagnosis. A prototype decision support system (DSS) designed to support GPs’ first impressions has been integrated with a commercial electronic health record (EHR) system. Aim To evaluate the prototype DSS in a high-fidelity simulation. Design and setting Within-participant design: 34 GPs consulted with six standardised patients (actors) using their usual EHR. On a different day, GPs used the EHR with the integrated DSS to consult with six other patients, matched for difficulty and counterbalanced. Method Entering the reason for encounter triggered the DSS, which provided a patient-specific list of potential diagnoses, and supported coding of symptoms during the consultation. At each consultation, GPs recorded their diagnosis and management. At the end, they completed a usability questionnaire. The actors completed a satisfaction questionnaire after each consultation. Results There was an 8–9% absolute improvement in diagnostic accuracy when the DSS was used. This improvement was significant (odds ratio [OR] 1.41, 95% confidence interval [CI] = 1.13 to 1.77, PGPs coded significantly more data when using the DSS (mean 12.35 with the DSS versus 1.64 without), and were generally satisfied with its usability. Patient satisfaction ratings were the same for consultations with and without the DSS. Conclusion The DSS prototype was successfully employed in simulated consultations of high fidelity, with no measurable influences on patient satisfaction. The substantially increased data coding can operate as motivation for future DSS adoption. PMID:28137782

  13. High Accuracy Microwave Frequency Measurement Based on Single-Drive Dual-Parallel Mach-Zehnder Modulator

    DEFF Research Database (Denmark)

    Zhao, Ying; Deng, Lei; Pang, Xiaodan

    2011-01-01

    A novel approach for broadband microwave frequency measurement based on bias manipulation of a dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. A 10-3 relative error verifies a significant accuracy improvement by this method.......A novel approach for broadband microwave frequency measurement based on bias manipulation of a dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. A 10-3 relative error verifies a significant accuracy improvement by this method....

  14. Addition of heart score to high-sensitivity troponin T versus conventional troponin T in risk stratification of patients with chest pain at the coronary emergency rooms.

    Science.gov (United States)

    Willems, M N I; van de Wijngaart, D J; Bergman, H; Adiyaman, A; Telting, D; Willems, F F

    2014-12-01

    Patients with chest pain have a large impact on available resources in coronary emergency rooms (CER). Clinical judgement, ECG, risk scores and biomarkers guide in risk stratification. We investigated if high-sensitivity troponin T (HsT) and the HEART Score could contribute to risk stratification at the CER. All patients with chest pain, without elevated conventional troponin levels at presentation, were included. HsT levels were determined at admission (T1), at 4-6 h (T2) and 8-10 h after symptom onset (T3). The HEART Score was calculated as risk score for the occurrence of a major adverse cardiac event (MACE). Thirty days after discharge, occurrence of MACE was registered. Eighty-nine patients were included (overall mean age 61 years (range 20-90)). At presentation, 68 patients (76 %) had a HsT below cut-off value of 14 ng/l (mean HEART Score 3.7, range 1-9). Thirty-one of these 68 patients had a HEART Score between 1-3, no MACE occurred in this group. For 3 patients (4 %) HsT levels increased above 14 ng/l. These 3 patients had a HEART Score between 4-6. The majority of patients with chest pain can be safely discharged within 4-6 h after onset of symptoms using HsT and the HEART Score. In contrast, patients with initially normal HsT but a high HEART Score need longer follow-up and repeat HsT determination.

  15. High prevalence of methotrexate intolerance in juvenile idiopathic arthritis: development and validation of a methotrexate intolerance severity score

    NARCIS (Netherlands)

    Bulatovic, M.; Heijstek, M.W.; Verkaaik, M.; Dijkhuizen, E.H. van; Armbrust, W.; Hoppenreijs, E.P.A.H.; Kamphuis, S.; Kuis, W.; Egberts, T.C.; Sinnema, G.; Rademaker, C.M.A.; Wulffraat, N.M.

    2011-01-01

    OBJECTIVE: To design and validate a new questionnaire for identifying patients with methotrexate (MTX) intolerance, and to determine the prevalence of MTX intolerance in patients with juvenile idiopathic arthritis (JIA) using this questionnaire. METHODS: The MTX Intolerance Severity Score (MISS)

  16. High prevalence of methotrexate intolerance in juvenile idiopathic arthritis : development and validation of a methotrexate intolerance severity score

    NARCIS (Netherlands)

    Bulatović, Maja; Heijstek, Marloes W; Verkaaik, Marleen; van Dijkhuizen, E H Pieter; Armbrust, Wineke; Hoppenreijs, Esther P A; Kamphuis, Sylvia; Kuis, Wietse; Egberts, Toine C G; Sinnema, Gerben; Rademaker, Carin M A; Wulffraat, Nico M

    OBJECTIVE: To design and validate a new questionnaire for identifying patients with methotrexate (MTX) intolerance, and to determine the prevalence of MTX intolerance in patients with juvenile idiopathic arthritis (JIA) using this questionnaire. METHODS: The MTX Intolerance Severity Score (MISS)

  17. A correlation study of Gleason score and the diagnostic accuracy of MRS in prostate cancer based on pathological section%MRS诊断前列腺癌准确率与病理切片Gleason评分的相关性研究

    Institute of Scientific and Technical Information of China (English)

    程紫琚; 赵阳; 白玫; 韩悦; 李辛子

    2012-01-01

    Objective: To investigate the diagnostic accuracy of magnetic resonance spectroscopy (MRS) in prostate cancer (PCa) and its correlation with Gleason score by making a comparative study of prostate MRS and the corresponding pathological section. Methods: Radical perineal prostatectomy was performed in 5 patients with PCa. Before operation, all the patients underwent prostate MRS scanning. According to the widest cross section in prostate 3D-MRS image, the interested layer of radical prostatectomy specimens were selected and sliced. On the basis of MRS voxels, the interested layer was cut into 15~ 35 pieces equally. Each piece was numbered in agreement with the order of MRS voxels and made into pathological sections. The diagnosis of MRS was compared to pathological finding in the same area. The correlation between the ratio of (choline+ creatine)/citrate(CC/C) and Gleason score was evaluated. According to the difference of Gleason score, the PCa regions were divided into several groups. The relationship of Gleason score and diagnostic accuracy of MRS in PCa was researched by Spearman's rank correlation analysis. Results: 90 regions with valid pathologic diagnosis were obtained in total. Using CC/C>0.86 as the diagnostic standard, 65 cancer-affected regions and 25 cancer-free regions were diagnosed by MRS, among which the results consistent with pathologic diagnosis were 59 and 14, respectively. There was a significant positive correlation between the rati