WorldWideScience

Sample records for high accuracy methods

  1. Novel method for high accuracy figure measurement of optical flat

    Science.gov (United States)

    E, Kewei; Li, Dahai; Yang, Lijie; Guo, Guangrao; Li, Mengyang; Wang, Xuemin; Zhang, Tao; Xiong, Zhao

    2017-01-01

    Phase Measuring Deflectometry (PMD) is a non-contact, high dynamic-range and full-field metrology which becomes a serious competitor to interferometry. However, the accuracy of deflectometry metrology is strongly influenced by the level of the calibrations, including test geometry, imaging pin-hole camera and digital display. In this paper, we propose a novel method that can measure optical flat surface figure to a high accuracy. We first calibrate the camera using a checker pattern shown on a LCD display at six different orientations, and the last orientation is aligned at the same position as the test optical flat. By using this method, lens distortions and the mapping relationship between the CCD pixels and the subaperture coordinates on the test optical flat can be determined at the same time. To further reduce the influence of the calibration errors on measurements, a reference optical flat with a high quality surface is measured, and then the system errors in our PMD setup can be eliminated by subtracting the figure of the reference flat from the figure of the test flat. Although any expensive coordinates measuring machine, such as laser tracker and coordinates measuring machine are not applied in our measurement, our experimental results of optical flat figure from low to high order aberrations still show a good agreement with that from the Fizeau interferometer.

  2. High accuracy mantle convection simulation through modern numerical methods

    KAUST Repository

    Kronbichler, Martin

    2012-08-21

    Numerical simulation of the processes in the Earth\\'s mantle is a key piece in understanding its dynamics, composition, history and interaction with the lithosphere and the Earth\\'s core. However, doing so presents many practical difficulties related to the numerical methods that can accurately represent these processes at relevant scales. This paper presents an overview of the state of the art in algorithms for high-Rayleigh number flows such as those in the Earth\\'s mantle, and discusses their implementation in the Open Source code Aspect (Advanced Solver for Problems in Earth\\'s ConvecTion). Specifically, we show how an interconnected set of methods for adaptive mesh refinement (AMR), higher order spatial and temporal discretizations, advection stabilization and efficient linear solvers can provide high accuracy at a numerical cost unachievable with traditional methods, and how these methods can be designed in a way so that they scale to large numbers of processors on compute clusters. Aspect relies on the numerical software packages deal.II and Trilinos, enabling us to focus on high level code and keeping our implementation compact. We present results from validation tests using widely used benchmarks for our code, as well as scaling results from parallel runs. © 2012 The Authors Geophysical Journal International © 2012 RAS.

  3. Researches on High Accuracy Prediction Methods of Earth Orientation Parameters

    Science.gov (United States)

    Xu, X. Q.

    2015-09-01

    The Earth rotation reflects the coupling process among the solid Earth, atmosphere, oceans, mantle, and core of the Earth on multiple spatial and temporal scales. The Earth rotation can be described by the Earth's orientation parameters, which are abbreviated as EOP (mainly including two polar motion components PM_X and PM_Y, and variation in the length of day ΔLOD). The EOP is crucial in the transformation between the terrestrial and celestial reference systems, and has important applications in many areas such as the deep space exploration, satellite precise orbit determination, and astrogeodynamics. However, the EOP products obtained by the space geodetic technologies generally delay by several days to two weeks. The growing demands for modern space navigation make high-accuracy EOP prediction be a worthy topic. This thesis is composed of the following three aspects, for the purpose of improving the EOP forecast accuracy. (1) We analyze the relation between the length of the basic data series and the EOP forecast accuracy, and compare the EOP prediction accuracy for the linear autoregressive (AR) model and the nonlinear artificial neural network (ANN) method by performing the least squares (LS) extrapolations. The results show that the high precision forecast of EOP can be realized by appropriate selection of the basic data series length according to the required time span of EOP prediction: for short-term prediction, the basic data series should be shorter, while for the long-term prediction, the series should be longer. The analysis also showed that the LS+AR model is more suitable for the short-term forecasts, while the LS+ANN model shows the advantages in the medium- and long-term forecasts. (2) We develop for the first time a new method which combines the autoregressive model and Kalman filter (AR+Kalman) in short-term EOP prediction. The equations of observation and state are established using the EOP series and the autoregressive coefficients

  4. A High Accuracy Method for Semi-supervised Information Extraction

    Energy Technology Data Exchange (ETDEWEB)

    Tratz, Stephen C.; Sanfilippo, Antonio P.

    2007-04-22

    Customization to specific domains of dis-course and/or user requirements is one of the greatest challenges for today’s Information Extraction (IE) systems. While demonstrably effective, both rule-based and supervised machine learning approaches to IE customization pose too high a burden on the user. Semi-supervised learning approaches may in principle offer a more resource effective solution but are still insufficiently accurate to grant realistic application. We demonstrate that this limitation can be overcome by integrating fully-supervised learning techniques within a semi-supervised IE approach, without increasing resource requirements.

  5. About accuracy of the discrimination parameter estimation for the dual high-energy method

    Science.gov (United States)

    Osipov, S. P.; Chakhlov, S. V.; Osipov, O. S.; Shtein, A. M.; Strugovtsev, D. V.

    2015-04-01

    A set of the mathematical formulas to estimate the accuracy of discrimination parameters for two implementations of the dual high energy method - by the effective atomic number and by the level lines is given. The hardware parameters which influenced on the accuracy of the discrimination parameters are stated. The recommendations to form the structure of the high energy X-ray radiation impulses are formulated. To prove the applicability of the proposed procedure there were calculated the statistical errors of the discrimination parameters for the cargo inspection system of the Tomsk polytechnic university on base of the portable betatron MIB-9. The comparison of the experimental estimations and the theoretical ones of the discrimination parameter errors was carried out. It proved the practical applicability of the algorithm to estimate the discrimination parameter errors for the dual high energy method.

  6. Optical System Error Analysis and Calibration Method of High-Accuracy Star Trackers

    Directory of Open Access Journals (Sweden)

    Zheng You

    2013-04-01

    Full Text Available The star tracker is a high-accuracy attitude measurement device widely used in spacecraft. Its performance depends largely on the precision of the optical system parameters. Therefore, the analysis of the optical system parameter errors and a precise calibration model are crucial to the accuracy of the star tracker. Research in this field is relatively lacking a systematic and universal analysis up to now. This paper proposes in detail an approach for the synthetic error analysis of the star tracker, without the complicated theoretical derivation. This approach can determine the error propagation relationship of the star tracker, and can build intuitively and systematically an error model. The analysis results can be used as a foundation and a guide for the optical design, calibration, and compensation of the star tracker. A calibration experiment is designed and conducted. Excellent calibration results are achieved based on the calibration model. To summarize, the error analysis approach and the calibration method are proved to be adequate and precise, and could provide an important guarantee for the design, manufacture, and measurement of high-accuracy star trackers.

  7. High-accuracy infra-red thermography method using reflective marker arrays

    Science.gov (United States)

    Kirollos, Benjamin; Povey, Thomas

    2017-09-01

    In this paper, we describe a new method for high-accuracy infra-red (IR) thermography measurements in situations with significant spatial variation in reflected radiation from the surroundings, or significant spatial variation in surface emissivity due to viewing angle non-uniformity across the field of view. The method employs a reflective marker array (RMA) on the target surface—typically, high emissivity circular dots—and an integrated image analysis algorithm designed to require minimal human input. The new technique has two particular advantages which make it suited to high-accuracy measurements in demanding environments: (i) it allows the reflected radiation component to be calculated directly, in situ, and as a function of position, overcoming a key problem in measurement environments with non-uniform and unsteady stray radiation from the surroundings; (ii) using image analysis of the marker array (via apparent aspect ratio of the circular reflective markers), the local viewing angle of the target surface can be estimated, allowing corrections for angular variation of local emissivity to be performed without prior knowledge of the geometry. A third advantage of the technique is that allows for simple focus-stacking algorithms due to increased image entropy. The reflective marker array method is demonstrated for an isothermal, hemispherical object exposed to an external IR source arranged to give a significant non-uniform reflected radiation term. This is an example of a challenging environment, both because of the significant non-uniform reflected radiation term, and also the significant variation in target emissivity due to surface angle variation. We demonstrate that the new RMA IR technique leads to significantly lower error in evaluated surface temperature than conventional IR techniques. The method is applicable to any complex radiative environment.

  8. ADFE METHOD WITH HIGH ACCURACY FOR NONLINEAR PARABOLIC INTEGRO-DIFFERENTIAL SYSTEM WITH NONLINEAR BOUNDARY CONDITIONS

    Institute of Scientific and Technical Information of China (English)

    崔霞

    2002-01-01

    Alternating direction finite element (ADFE) scheme for d-dimensional nonlinear system of parabolic integro-differential equations is studied. By using a local approximation based on patches of finite elements to treat the capacity term qi(u), decomposition of the coefficient matrix is realized; by using alternating direction, the multi-dimensional problem is reduced to a family of single space variable problems, calculation work is simplified; by using finite element method, high accuracy for space variant is kept; by using inductive hypothesis reasoning, the difficulty coming from the nonlinearity of the coefficients and boundary conditions is treated; by introducing Ritz-Volterra projection, the difficulty coming from the memory term is solved. Finally, by using various techniques for priori estimate for differential equations, the unique resolvability and convergence properties for both FE and ADFE schemes are rigorously demonstrated, and optimal H1 and L2norm space estimates and O((△t)2) estimate for time variant are obtained.

  9. HIGH ACCURACY FINITE VOLUME ELEMENT METHOD FOR TWO-POINT BOUNDARY VALUE PROBLEM OF SECOND ORDER ORDINARY DIFFERENTIAL EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    王同科

    2002-01-01

    In this paper, a high accuracy finite volume element method is presented for two-point boundary value problem of second order ordinary differential equation, which differs fromthe high order generalized difference methods. It is proved that the method has optimal order er-ror estimate O(h3) in H1 norm. Finally, two examples show that the method is effective.

  10. Statistical downscaling of precipitation using local regression and high accuracy surface modeling method

    Science.gov (United States)

    Zhao, Na; Yue, Tianxiang; Zhou, Xun; Zhao, Mingwei; Liu, Yu; Du, Zhengping; Zhang, Lili

    2017-07-01

    Downscaling precipitation is required in local scale climate impact studies. In this paper, a statistical downscaling scheme was presented with a combination of geographically weighted regression (GWR) model and a recently developed method, high accuracy surface modeling method (HASM). This proposed method was compared with another downscaling method using the Coupled Model Intercomparison Project Phase 5 (CMIP5) database and ground-based data from 732 stations across China for the period 1976-2005. The residual which was produced by GWR was modified by comparing different interpolators including HASM, Kriging, inverse distance weighted method (IDW), and Spline. The spatial downscaling from 1° to 1-km grids for period 1976-2005 and future scenarios was achieved by using the proposed downscaling method. The prediction accuracy was assessed at two separate validation sites throughout China and Jiangxi Province on both annual and seasonal scales, with the root mean square error (RMSE), mean relative error (MRE), and mean absolute error (MAE). The results indicate that the developed model in this study outperforms the method that builds transfer function using the gauge values. There is a large improvement in the results when using a residual correction with meteorological station observations. In comparison with other three classical interpolators, HASM shows better performance in modifying the residual produced by local regression method. The success of the developed technique lies in the effective use of the datasets and the modification process of the residual by using HASM. The results from the future climate scenarios show that precipitation exhibits overall increasing trend from T1 (2011-2040) to T2 (2041-2070) and T2 to T3 (2071-2100) in RCP2.6, RCP4.5, and RCP8.5 emission scenarios. The most significant increase occurs in RCP8.5 from T2 to T3, while the lowest increase is found in RCP2.6 from T2 to T3, increased by 47.11 and 2.12 mm, respectively.

  11. Statistical downscaling of precipitation using local regression and high accuracy surface modeling method

    Science.gov (United States)

    Zhao, Na; Yue, Tianxiang; Zhou, Xun; Zhao, Mingwei; Liu, Yu; Du, Zhengping; Zhang, Lili

    2016-03-01

    Downscaling precipitation is required in local scale climate impact studies. In this paper, a statistical downscaling scheme was presented with a combination of geographically weighted regression (GWR) model and a recently developed method, high accuracy surface modeling method (HASM). This proposed method was compared with another downscaling method using the Coupled Model Intercomparison Project Phase 5 (CMIP5) database and ground-based data from 732 stations across China for the period 1976-2005. The residual which was produced by GWR was modified by comparing different interpolators including HASM, Kriging, inverse distance weighted method (IDW), and Spline. The spatial downscaling from 1° to 1-km grids for period 1976-2005 and future scenarios was achieved by using the proposed downscaling method. The prediction accuracy was assessed at two separate validation sites throughout China and Jiangxi Province on both annual and seasonal scales, with the root mean square error (RMSE), mean relative error (MRE), and mean absolute error (MAE). The results indicate that the developed model in this study outperforms the method that builds transfer function using the gauge values. There is a large improvement in the results when using a residual correction with meteorological station observations. In comparison with other three classical interpolators, HASM shows better performance in modifying the residual produced by local regression method. The success of the developed technique lies in the effective use of the datasets and the modification process of the residual by using HASM. The results from the future climate scenarios show that precipitation exhibits overall increasing trend from T1 (2011-2040) to T2 (2041-2070) and T2 to T3 (2071-2100) in RCP2.6, RCP4.5, and RCP8.5 emission scenarios. The most significant increase occurs in RCP8.5 from T2 to T3, while the lowest increase is found in RCP2.6 from T2 to T3, increased by 47.11 and 2.12 mm, respectively.

  12. HIGH-ACCURACY BAND TO BAND REGISTRATION METHOD FOR MULTI-SPECTRAL IMAGES OF HJ-1A/B

    Institute of Scientific and Technical Information of China (English)

    Lu Hao; Liu Tuanjie; Zhao Haiqing

    2012-01-01

    Band-to-band registration accuracy is an important parameter of multispectral data.A novel band-to-band registration approach with high precision is proposed for the multi-spectral images of HJ-1A/B.Firstly,the main causes resulted in misregistration are analyzed,and a high-order polynomial model is proposed.Secondly,a phase fringe filtering technique is employed to Phase Correlation Method based on Singular Value Decomposition (SVD-PCM) for reducing the noise in phase difference matrix.Then,experiments are carried out to build nonlinear registration models,and images of green band and red band are aligned to blue band with an accuracy of 0.1 pixels,while near infrared band with an accuracy of 0.2 pixels.

  13. High-Accuracy, Compact Scanning Method and Circuit for Resistive Sensor Arrays

    Directory of Open Access Journals (Sweden)

    Jong-Seok Kim

    2016-01-01

    Full Text Available The zero-potential scanning circuit is widely used as read-out circuit for resistive sensor arrays because it removes a well known problem: crosstalk current. The zero-potential scanning circuit can be divided into two groups based on type of row drivers. One type is a row driver using digital buffers. It can be easily implemented because of its simple structure, but we found that it can cause a large read-out error which originates from on-resistance of the digital buffers used in the row driver. The other type is a row driver composed of operational amplifiers. It, very accurately, reads the sensor resistance, but it uses a large number of operational amplifiers to drive rows of the sensor array; therefore, it severely increases the power consumption, cost, and system complexity. To resolve the inaccuracy or high complexity problems founded in those previous circuits, we propose a new row driver which uses only one operational amplifier to drive all rows of a sensor array with high accuracy. The measurement results with the proposed circuit to drive a 4 × 4 resistor array show that the maximum error is only 0.1% which is remarkably reduced from 30.7% of the previous counterpart.

  14. High-accuracy CFD prediction methods for fluid and structure temperature fluctuations at T-junction for thermal fatigue evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Shaoxiang, E-mail: qian.shaoxiang@jgc.com [EN Technology Center, Process Technology Division, JGC Corporation, 2-3-1 Minato Mirai, Nishi-ku, Yokohama 220-6001 (Japan); Kanamaru, Shinichiro [EN Technology Center, Process Technology Division, JGC Corporation, 2-3-1 Minato Mirai, Nishi-ku, Yokohama 220-6001 (Japan); Kasahara, Naoto [Nuclear Engineering and Management, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2015-07-15

    Highlights: • Numerical methods for accurate prediction of thermal loading were proposed. • Predicted fluid temperature fluctuation (FTF) intensity is close to the experiment. • Predicted structure temperature fluctuation (STF) range is close to the experiment. • Predicted peak frequencies of FTF and STF also agree well with the experiment. • CFD results show the proposed numerical methods are of sufficiently high accuracy. - Abstract: Temperature fluctuations generated by the mixing of hot and cold fluids at a T-junction, which is widely used in nuclear power and process plants, can cause thermal fatigue failure. The conventional methods for evaluating thermal fatigue tend to provide insufficient accuracy, because they were developed based on limited experimental data and a simplified one-dimensional finite element analysis (FEA). CFD/FEA coupling analysis is expected as a useful tool for the more accurate evaluation of thermal fatigue. The present paper aims to verify the accuracy of proposed numerical methods of simulating fluid and structure temperature fluctuations at a T-junction for thermal fatigue evaluation. The dynamic Smagorinsky model (DSM) is used for large eddy simulation (LES) sub-grid scale (SGS) turbulence model, and a hybrid scheme (HS) is adopted for the calculation of convective terms in the governing equations. Also, heat transfer between fluid and structure is calculated directly through thermal conduction by creating a mesh with near wall resolution (NWR) by allocating grid points within the thermal boundary sub-layer. The simulation results show that the distribution of fluid temperature fluctuation intensity and the range of structure temperature fluctuation are remarkably close to the experimental results. Moreover, the peak frequencies of power spectrum density (PSD) of both fluid and structure temperature fluctuations also agree well with the experimental results. Therefore, the numerical methods used in the present paper are

  15. Hyperbolic Method for Dispersive PDEs: Same High-Order of Accuracy for Solution, Gradient, and Hessian

    Science.gov (United States)

    Mazaheri, Alireza; Ricchiuto, Mario; Nishikawa, Hiroaki

    2016-01-01

    In this paper, we introduce a new hyperbolic first-order system for general dispersive partial differential equations (PDEs). We then extend the proposed system to general advection-diffusion-dispersion PDEs. We apply the fourth-order RD scheme of Ref. 1 to the proposed hyperbolic system, and solve time-dependent dispersive equations, including the classical two-soliton KdV and a dispersive shock case. We demonstrate that the predicted results, including the gradient and Hessian (second derivative), are in a very good agreement with the exact solutions. We then show that the RD scheme applied to the proposed system accurately captures dispersive shocks without numerical oscillations. We also verify that the solution, gradient and Hessian are predicted with equal order of accuracy.

  16. A simple method for measuring the superhydrophobic contact angle with high accuracy

    Science.gov (United States)

    Hung, Yi-Lin; Chang, Yao-Yuan; Wang, Meng-Jiy; Lin, Shi-Yow

    2010-06-01

    A modified selected-plane method for contact angle (θ) measurement is proposed in this study that avoids the difficulty of finding the real contact point and image-distortion effects adjacent to the contact point. This method is particularly suitable for superhydrophobic surfaces. The sessile-drop method coupled with the tangent line is the most popular method to find the contact angle in literature, but it entails unavoidable errors in determining the air-solid base line due to the smoothness problem and substrate tilting. In addition, the tangent-line technique requires finding the actual contact point. The measurement error due to the base line problem becomes more profound for superhydrophobic surfaces. A larger θ deviation results from a more superhydrophobic surface with a fixed base line error. The proposed modified selected-plane method requires only four data points (droplet apex, droplet height, and two interfacial loci close to the air-solid interface), avoiding the problem of the sessile-drop-tangent method in finding the contact point and saving the trouble of the sessile-drop-fitting method for best fitting of the numerous edge points with the theoretical profile. A careful error analysis was performed, and a user-friendly program was provided in this work. This method resulted in an accurate θ measurement and a method that was much improved over the classical selected plane and the sessile-drop-tangent methods. The θ difference between this method and the sessile-drop-fitting method was found to be less than three degrees.

  17. Novel method of high-accuracy wavefront-phase and amplitude correction for coronagraphy

    Science.gov (United States)

    Bowers, Charles W.; Woodgate, Bruce E.; Lyon, Richard G.

    2003-11-01

    Detection of extra-solar, and especially terrestrial-like planets, using coronagraphy requires an extremely high level of wavefront correction. For example, the study of Woodruff et al. (2002) has shown that phase uniformity of order 10-4λ(rms) must be achieved over the critical range of spatial frequencies to produce the ~1010 contrast needed for the Terrestrial Planet Finder (TPF) mission. Correction of wavefront phase errors to this level may be accomplished by using a very high precision deformable mirror (DM). However, not only phase but also amplitude uniformity of the same scale (~10-4) and over the same spatial frequency range must be simultaneously obtained to remove all residual speckle in the image plane. We present a design for producing simultaneous wavefront phase and amplitude uniformity to high levels from an input wavefront of lower quality. The design uses a dual Michelson interferometer arrangement incorporating two DM and a single, fixed mirror (all at pupils) and two beamsplitters: one with unequal (asymmetric) beam splitting and one with symmetric beam splitting. This design allows high precision correction of both phase and amplitude using DM with relatively coarse steps and permits a simple correction algorithm.

  18. High accuracy computational methods for behavioral modeling of thick-film resistors at cryogenic temperatures

    Directory of Open Access Journals (Sweden)

    Balik Franciszek

    2016-03-01

    Full Text Available The aim of this work was to elaborate two-dimensional behavioral modeling method of thick-film resistors working in low-temperature conditions. The investigated resistors (made from 5 various resistive inks: 10 resistor coupons, each with 36 resistors with various dimensions, were measured automatically in a cryostat system. The low temperature was achieved in a nitrogen-helium continuous-flow cryostat. For nitrogen used as a freezing liquid the minimal temperature possible to achieve was equal to −195.85 °C (77.3 K. Mathematical model in the form of a multiplication of two polynomials was elaborated based on the above mentioned measurements. The first polynomial approximated temperature behavior of the normalized resistance, while the second one described the dependence of resistance on planar resistors dimensions. Special computational procedures for multidimensional approximation purpose were elaborated. It was shown that proper approximation polynomials and sufficiently exact methods of calculations ensure acceptable modeling errors.

  19. High-Accuracy Methods for Numerical Flow Analysis Using Adaptive Non-Linear Wavelets

    Science.gov (United States)

    2012-08-01

    to the research by Bacry, Mallat and Papanicolaou [10] or Holmström and Walden [11], AWGM solves PDE problems in a wavelet coefficient space. It is...of the threshold value, these variations are discarded and restricted by multiplying the weighting factor . This process can especially contribute the...weighting factor . This restriction technique enhances the convergence rate of steady state calculations. References [1] Harten A., “High

  20. Method for high-accuracy reflectance measurements in the 2.5-microm region.

    Science.gov (United States)

    Richter, Rudolf; Müller, Andreas

    2003-02-20

    Reflectance measurement with spectroradiometers in the solar wavelength region (0.4-2.5 microm) are frequently conducted in the laboratory or in the field to characterize surface materials of artificial and natural targets. The spectral surface reflectance is calculated as the ratio of the signals obtained over the target surface and a reference panel, yielding a relative reflectance value. If the reflectance of the reference panel is known, the absolute target reflectance can be computed. This standard measurement technique assumes that the signal at the radiometer is due completely to reflected target and reference radiation. However, for field measurements in the 2.4-2.5-microm region with the Sun as the illumination source, the emitted thermal radiation is not a negligible part of the signal even at ambient temperatures, because the atmospheric transmittance, and thus the solar illumination level, is small in the atmospheric absorption regions. A new method is proposed that calculates reflectance values in the 2.4-2.5-microm region while it accounts for the reference panel reflectance and the emitted radiation. This technique needs instruments with noise-equivalent radiances of 2 orders of magnitude below currently commercially available instruments and requires measurement of the surface temperatures of target and reference. If the reference panel reflectance and temperature effects are neglected, the standard method yields reflectance errors up to 0.08 and 0.15 units for 7- and 2-nm bandwidth instruments, respectively. For the new method the corresponding errors can be reduced to approximately 0.01 units for the surface temperature range of 20-35 degrees C.

  1. A new TEC interpolation method based on the least squares collocation for high accuracy regional ionospheric maps

    Science.gov (United States)

    Krypiak-Gregorczyk, Anna; Wielgosz, Paweł; Jarmołowski, Wojciech

    2017-04-01

    The ionosphere plays a crucial role in space weather that affects satellite navigation as the ionospheric delay is one of the major errors in GNSS. On the other hand, GNSS observations are widely used to determine the amount of ionospheric total electron content (TEC). An important aspect in the electron content estimation at regional and global scale is adopting the appropriate interpolation strategy. In this paper we propose and validate a new method for regional TEC modeling based on least squares collocation (LSC) with noise variance estimation. This method allows for providing accurate TEC maps with high spatial and temporal resolution. Such maps may be used to support precise GNSS positioning and navigation, e.g. in RTK mode and also in the ionosphere studies. To test applicability of new TEC maps to positioning, double-difference ionospheric corrections were derived from the maps and their accuracy was analyzed. In addition, the corrections were applied to GNSS positioning and validated in ambiguity resolution domain. The tests were carried out during a strong ionospheric storm when the ionosphere is particularly difficult to model. The performance of the new approach was compared to IGS and UPC global, and CODE regional TEC maps. The results showed an advantage of our solution with resulting accuracy of the relative ionospheric corrections usually better than 10 cm, even during the ionospheric disturbances. This proves suitability of our regional TEC maps for, e.g. supporting fast ambiguity resolution in kinematic GNSS positioning.

  2. A three axis turntable's online initial state measurement method based on the high-accuracy laser gyro SINS

    Science.gov (United States)

    Gao, Chunfeng; Wei, Guo; Wang, Qi; Xiong, Zhenyu; Wang, Qun; Long, Xingwu

    2016-10-01

    As an indispensable equipment in inertial technology tests, the three-axis turntable is widely used in the calibration of various types inertial navigation systems (INS). In order to ensure the calibration accuracy of INS, we need to accurately measure the initial state of the turntable. However, the traditional measuring method needs a lot of exterior equipment (such as level instrument, north seeker, autocollimator, etc.), and the test processing is complex, low efficiency. Therefore, it is relatively difficult for the inertial measurement equipment manufacturers to realize the self-inspection of the turntable. Owing to the high precision attitude information provided by the laser gyro strapdown inertial navigation system (SINS) after fine alignment, we can use it as the attitude reference of initial state measurement of three-axis turntable. For the principle that the fixed rotation vector increment is not affected by measuring point, we use the laser gyro INS and the encoder of the turntable to provide the attitudes of turntable mounting plat. Through this way, the high accuracy measurement of perpendicularity error and initial attitude of the three-axis turntable has been achieved.

  3. Parallel High Order Accuracy Methods Applied to Non-Linear Hyperbolic Equations and to Problems in Materials Sciences

    Energy Technology Data Exchange (ETDEWEB)

    Jan Hesthaven

    2012-02-06

    Final report for DOE Contract DE-FG02-98ER25346 entitled Parallel High Order Accuracy Methods Applied to Non-Linear Hyperbolic Equations and to Problems in Materials Sciences. Principal Investigator Jan S. Hesthaven Division of Applied Mathematics Brown University, Box F Providence, RI 02912 Jan.Hesthaven@Brown.edu February 6, 2012 Note: This grant was originally awarded to Professor David Gottlieb and the majority of the work envisioned reflects his original ideas. However, when Prof Gottlieb passed away in December 2008, Professor Hesthaven took over as PI to ensure proper mentoring of students and postdoctoral researchers already involved in the project. This unusual circumstance has naturally impacted the project and its timeline. However, as the report reflects, the planned work has been accomplished and some activities beyond the original scope have been pursued with success. Project overview and main results The effort in this project focuses on the development of high order accurate computational methods for the solution of hyperbolic equations with application to problems with strong shocks. While the methods are general, emphasis is on applications to gas dynamics with strong shocks.

  4. High accuracy flexural hinge development

    Science.gov (United States)

    Santos, I.; Ortiz de Zárate, I.; Migliorero, G.

    2005-07-01

    This document provides a synthesis of the technical results obtained in the frame of the HAFHA (High Accuracy Flexural Hinge Assembly) development performed by SENER (in charge of design, development, manufacturing and testing at component and mechanism levels) with EADS Astrium as subcontractor (in charge of doing an inventory of candidate applications among existing and emerging projects, establishing the requirements and perform system level testing) under ESA contract. The purpose of this project has been to develop a competitive technology for a flexural pivot, usuable in highly accurate and dynamic pointing/scanning mechanisms. Compared with other solutions (e.g. magnetic or ball bearing technologies) flexural hinges are the appropriate technology for guiding with accuracy a mobile payload over a limited angular ranges around one rotation axes.

  5. High accuracy FIONA-AFM hybrid imaging.

    Science.gov (United States)

    Fronczek, D N; Quammen, C; Wang, H; Kisker, C; Superfine, R; Taylor, R; Erie, D A; Tessmer, I

    2011-04-01

    Multi-protein complexes are ubiquitous and play essential roles in many biological mechanisms. Single molecule imaging techniques such as electron microscopy (EM) and atomic force microscopy (AFM) are powerful methods for characterizing the structural properties of multi-protein and multi-protein-DNA complexes. However, a significant limitation to these techniques is the ability to distinguish different proteins from one another. Here, we combine high resolution fluorescence microscopy and AFM (FIONA-AFM) to allow the identification of different proteins in such complexes. Using quantum dots as fiducial markers in addition to fluorescently labeled proteins, we are able to align fluorescence and AFM information to ≥8nm accuracy. This accuracy is sufficient to identify individual fluorescently labeled proteins in most multi-protein complexes. We investigate the limitations of localization precision and accuracy in fluorescence and AFM images separately and their effects on the overall registration accuracy of FIONA-AFM hybrid images. This combination of the two orthogonal techniques (FIONA and AFM) opens a wide spectrum of possible applications to the study of protein interactions, because AFM can yield high resolution (5-10nm) information about the conformational properties of multi-protein complexes and the fluorescence can indicate spatial relationships of the proteins in the complexes.

  6. High-accuracy 2D digital image correlation measurements using low-cost imaging lenses: implementation of a generalized compensation method

    Science.gov (United States)

    Pan, Bing; Yu, Liping; Wu, Dafang

    2014-02-01

    The ideal pinhole imaging model commonly assumed for an ordinary two-dimensional digital image correlation (2D-DIC) system is neither perfect nor stable because of the existence of small out-of-plane motion of the test sample surface that occurred after loading, small out-of-plane motion of the sensor target due to temperature variation of a camera and unavoidable geometric distortion of an imaging lens. In certain cases, these disadvantages can lead to significant errors in the measured displacements and strains. Although a high-quality bilateral telecentric lens has been strongly recommended to be used in the 2D-DIC system as an essential optical component to achieve high-accuracy measurement, it is not generally applicable due to its fixed field of view, limited depth of focus and high cost. To minimize the errors associated with the imperfectness and instability of a common 2D-DIC system using a low-cost imaging lens, a generalized compensation method using a non-deformable reference sample is proposed in this work. With the proposed method, the displacement of the reference sample rigidly attached behind the test sample is first measured using 2D-DIC, and then it is fitted using a parametric model. The fitted parametric model is then used to correct the displacements of the deformed sample to remove the influences of these unfavorable factors. The validity of the proposed compensation method is first verified using out-of-plane translation, out-of-plane rotation, in-plane translation tests and their combinations. Uniaxial tensile tests of an aluminum specimen were also performed to quantitatively examine the strain accuracy of the proposed compensation method. Experiments show that the proposed compensation method is an easy-to-implement yet effective technique for achieving high-accuracy deformation measurement using an ordinary 2D-DIC system.

  7. A simple high accuracy phase locked loop method%一种内同步高精度锁相环技术研究

    Institute of Scientific and Technical Information of China (English)

    耿攀; 吴卫民; 陈建明; 叶银忠; 刘以建

    2011-01-01

    本文提出一种适用于数字控制的内同步高精度锁相环方法.本方法实现简单,在系统正常工作情况下可以高精度跟踪电网同步信号.在失去电网同步信号后依然可以使系统按照原来的频率和相位继续稳定运行,更适用于需要在并网、离网自由切换工作的系统.本文首先详细分析了此处带内同步程序锁相环的工作原理,然后推导了采用这种锁相方法的具体精度,最后通过1kW样机实验验证了提出方法的正确性.%This paper proposes a simple high accuracy inner-synchronization phase locked loop method used for digital control. This method is very easy to be realized. When the system works under normal condition, it could track the grid synchronized signal in high accuracy. When the system losses the grid synchronized signal, it could keep stable operation under the former frequency and phase position, and it is more suitable for the systems which need to switch between grid-tied and stand-alone mode. In this paper, the working principle of the phase locked loop with inner-synchronized program is analyzed at first. The accuracy using this phase locked loop method is derived. Finally, experimental results on a l kW prototype prove the validity of the proposed method.

  8. A Software Module for High-Accuracy Calibration of Rings and Cylinders on CMM using Multi-Orientation Techniques (Multi-Step and Reversal methods)

    DEFF Research Database (Denmark)

    Tosello, Guido; De Chiffre, Leonardo

    . The Centre for Geometrical Metrology (CGM) at the Technical University of Denmark takes care of free form measurements, in collaboration with DIMEG, University of Padova, Italy. The present report describes a software module, ROUNDCAL, to be used for high-accuracy calibration of rings and cylinders....... The purpose of the software is to calculate the form error and the least square circle of rings and cylinders by mean of average of pontwise measuring results becoming from so-called multi-orientation techniques (both reversal and multi-step methods) in order to eliminate systematic errors of CMM ....

  9. A Software Module for High-Accuracy Calibration of Rings and Cylinders on CMM using Multi-Orientation Techniques (Multi-Step and Reversal methods)

    DEFF Research Database (Denmark)

    Tosello, Guido; De Chiffre, Leonardo

    . The Centre for Geometrical Metrology (CGM) at the Technical University of Denmark takes care of free form measurements, in collaboration with DIMEG, University of Padova, Italy. The present report describes a software module, ROUNDCAL, to be used for high-accuracy calibration of rings and cylinders....... The purpose of the software is to calculate the form error and the least square circle of rings and cylinders by mean of average of pontwise measuring results becoming from so-called multi-orientation techniques (both reversal and multi-step methods) in order to eliminate systematic errors of CMM ....

  10. High Accuracy On-line Measurement Method of Motion Error on Machine Tools Straight-going Parts

    Institute of Scientific and Technical Information of China (English)

    苏恒; 洪迈生; 魏元雷; 李自军

    2003-01-01

    Harmonic suppression, non-periodic and non-closing in straightness profile error that will bring about harmonic component distortion in measurement result are analyzed. The countermeasure-a novel accurate two-probe method in time domain is put forward to measure straight-going component motion error in machine tools based on the frequency domain 3-point method after symmetrical continuation of probes' primitive signal. Both straight-going component motion error in machine tools and the profile error in workpiece that is manufactured on this machine can be measured at the same time. The information is available to diagnose the fault origin of machine tools. The analysis result is proved to be correct by the experiment.

  11. Gravity Compensation Methods for High-Accuracy INS%高精度惯性导航系统重力补偿方法

    Institute of Scientific and Technical Information of China (English)

    陆志东; 王晶

    2016-01-01

    重力扰动是高精度惯性导航系统的一项重要误差源,重力补偿是降低惯性导航系统误差的一项关键技术。通过基于对确定性模型、数据及外部辅助3种重力补偿方法的分析和研究,总结得出了各补偿方法的研究方向以及适用范围,对进一步提高我国未来更高精度惯性导航系统的导航精度具有指导意义,并提供了方法上的参考。%Gravity disturbance is an important error source of high-accuracy inertial navigation system(INS). Gravity compensation is a critical technology to reduce error of INS. After analysing and researching deterministic model,data and external assist gravity compensation methods,research area and range of application were summarized. It can provide guidance and reference to improve INS’s navigation accuracy.

  12. Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units.

    Science.gov (United States)

    Cai, Qingzhong; Yang, Gongliu; Song, Ningfang; Liu, Yiliang

    2016-06-22

    An inertial navigation system (INS) has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 × 10(-6)°/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs) using common turntables, has a great application potential in future atomic gyro INSs.

  13. Systematic Calibration for Ultra-High Accuracy Inertial Measurement Units

    Directory of Open Access Journals (Sweden)

    Qingzhong Cai

    2016-06-01

    Full Text Available An inertial navigation system (INS has been widely used in challenging GPS environments. With the rapid development of modern physics, an atomic gyroscope will come into use in the near future with a predicted accuracy of 5 × 10−6°/h or better. However, existing calibration methods and devices can not satisfy the accuracy requirements of future ultra-high accuracy inertial sensors. In this paper, an improved calibration model is established by introducing gyro g-sensitivity errors, accelerometer cross-coupling errors and lever arm errors. A systematic calibration method is proposed based on a 51-state Kalman filter and smoother. Simulation results show that the proposed calibration method can realize the estimation of all the parameters using a common dual-axis turntable. Laboratory and sailing tests prove that the position accuracy in a five-day inertial navigation can be improved about 8% by the proposed calibration method. The accuracy can be improved at least 20% when the position accuracy of the atomic gyro INS can reach a level of 0.1 nautical miles/5 d. Compared with the existing calibration methods, the proposed method, with more error sources and high order small error parameters calibrated for ultra-high accuracy inertial measurement units (IMUs using common turntables, has a great application potential in future atomic gyro INSs.

  14. Accuracy verification methods theory and algorithms

    CERN Document Server

    Mali, Olli; Repin, Sergey

    2014-01-01

    The importance of accuracy verification methods was understood at the very beginning of the development of numerical analysis. Recent decades have seen a rapid growth of results related to adaptive numerical methods and a posteriori estimates. However, in this important area there often exists a noticeable gap between mathematicians creating the theory and researchers developing applied algorithms that could be used in engineering and scientific computations for guaranteed and efficient error control.   The goals of the book are to (1) give a transparent explanation of the underlying mathematical theory in a style accessible not only to advanced numerical analysts but also to engineers and students; (2) present detailed step-by-step algorithms that follow from a theory; (3) discuss their advantages and drawbacks, areas of applicability, give recommendations and examples.

  15. High Accuracy Imaging Polarimetry with NICMOS

    CERN Document Server

    Batcheldor, D; Hines, D C; Schmidt, G D; Axon, D J; Robinson, A; Sparks, W; Tadhunter, C

    2008-01-01

    The ability of NICMOS to perform high accuracy polarimetry is currently hampered by an uncalibrated residual instrumental polarization at a level of 1.2-1.5%. To better quantify and characterize this residual we obtained observations of three polarimetric standard stars at three separate space-craft roll angles. Combined with archival data, these observations were used to characterize the residual instrumental polarization to enable NICMOS to reach its full polarimetric potential. Using these data, we calculate values of the parallel transmission coefficients that reproduce the ground-based results for the polarimetric standards. The uncertainties associated with the parallel transmission coefficients, a result of the photometric repeatability of the observations, dominate the accuracy of p and theta. However, the new coefficients now enable imaging polarimetry of targets with p~1.0% at an accuracy of +/-0.6% and +/-15 degrees.

  16. Method for Improving the Ranging Accuracy of Radio Fuze

    Institute of Scientific and Technical Information of China (English)

    HU Xiu-juan; DENG Jia-hao; SANG Hui-ping

    2006-01-01

    Stepped frequency radar waveform is put forward for improving the accuracy of radio fuze ranging. IFFT is adopted to synthesize one dimension high resolution range profile. Furthermore, the same range reject method and selection maximum method are made use of removing target redundancy and the simulation results are given. Characters of the two methods are analyzed, and under the proposal of Weibull distribution clutter envelope, the CFAR same range selection maximum method is adopted and realizes the accurate profile and ranging.

  17. High Accuracy Transistor Compact Model Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Hembree, Charles E. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Mar, Alan [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Robertson, Perry J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspond- ingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirements require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantifi- cation of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transis- tors have been developed and are described in this report.

  18. High accuracy 3-D laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a mono-static staring 3-D laser radar based on gated viewing with range accuracy below 1 m at 10 m and 1 cm at 100. We use a high sensitivity, fast, intensified CCD camera, and a Nd:Yag passively Q-switched 32.4 kHz pulsed green laser at 532 nm. The CCD has 752x582 pixels. Camera...

  19. Density-Functional Theory with Dispersion-Correcting Potentials for Methane: Bridging the Efficiency and Accuracy Gap between High-Level Wave Function and Classical Molecular Mechanics Methods.

    Science.gov (United States)

    Torres, Edmanuel; DiLabio, Gino A

    2013-08-13

    Large clusters of noncovalently bonded molecules can only be efficiently modeled by classical mechanics simulations. One prominent challenge associated with this approach is obtaining force-field parameters that accurately describe noncovalent interactions. High-level correlated wave function methods, such as CCSD(T), are capable of correctly predicting noncovalent interactions, and are widely used to produce reference data. However, high-level correlated methods are generally too computationally costly to generate the critical reference data required for good force-field parameter development. In this work we present an approach to generate Lennard-Jones force-field parameters to accurately account for noncovalent interactions. We propose the use of a computational step that is intermediate to CCSD(T) and classical molecular mechanics, that can bridge the accuracy and computational efficiency gap between them, and demonstrate the efficacy of our approach with methane clusters. On the basis of CCSD(T)-level binding energy data for a small set of methane clusters, we develop methane-specific, atom-centered, dispersion-correcting potentials (DCPs) for use with the PBE0 density-functional and 6-31+G(d,p) basis sets. We then use the PBE0-DCP approach to compute a detailed map of the interaction forces associated with the removal of a single methane molecule from a cluster of eight methane molecules and use this map to optimize the Lennard-Jones parameters for methane. The quality of the binding energies obtained by the Lennard-Jones parameters we obtained is assessed on a set of methane clusters containing from 2 to 40 molecules. Our Lennard-Jones parameters, used in combination with the intramolecular parameters of the CHARMM force field, are found to closely reproduce the results of our dispersion-corrected density-functional calculations. The approach outlined can be used to develop Lennard-Jones parameters for any kind of molecular system.

  20. Computing High Accuracy Power Spectra with Pico

    CERN Document Server

    Fendt, William A

    2007-01-01

    This paper presents the second release of Pico (Parameters for the Impatient COsmologist). Pico is a general purpose machine learning code which we have applied to computing the CMB power spectra and the WMAP likelihood. For this release, we have made improvements to the algorithm as well as the data sets used to train Pico, leading to a significant improvement in accuracy. For the 9 parameter nonflat case presented here Pico can on average compute the TT, TE and EE spectra to better than 1% of cosmic standard deviation for nearly all $\\ell$ values over a large region of parameter space. Performing a cosmological parameter analysis of current CMB and large scale structure data, we show that these power spectra give very accurate 1 and 2 dimensional parameter posteriors. We have extended Pico to allow computation of the tensor power spectrum and the matter transfer function. Pico runs about 1500 times faster than CAMB at the default accuracy and about 250,000 times faster at high accuracy. Training Pico can be...

  1. Fast and High Accuracy Wire Scanner

    CERN Document Server

    Koujili, M; Koopman, J; Ramos, D; Sapinski, M; De Freitas, J; Ait Amira, Y; Djerdir, A

    2009-01-01

    Scanning of a high intensity particle beam imposes challenging requirements on a Wire Scanner system. It is expected to reach a scanning speed of 20 m.s-1 with a position accuracy of the order of 1 μm. In addition a timing accuracy better than 1 millisecond is needed. The adopted solution consists of a fork holding a wire rotating by a maximum of 200°. Fork, rotor and angular position sensor are mounted on the same axis and located in a chamber connected to the beam vacuum. The requirements imply the design of a system with extremely low vibration, vacuum compatibility, radiation and temperature tolerance. The adopted solution consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside of the vacuum chamber and the stator installed outside. The accurate position sensor will be mounted on the rotary shaft inside of the vacuum chamber, has to resist a bake-out temperature of 200°C and ionizing radiation up to a dozen of kGy/year. A digital feedback controller allows maxi...

  2. Effect of calibration method on Tekscan sensor accuracy.

    Science.gov (United States)

    Brimacombe, Jill M; Wilson, David R; Hodgson, Antony J; Ho, Karen C T; Anglin, Carolyn

    2009-03-01

    Tekscan pressure sensors are used in biomechanics research to measure joint contact loads. While the overall accuracy of these sensors has been reported previously, the effects of different calibration algorithms on sensor accuracy have not been compared. The objectives of this validation study were to determine the most appropriate calibration method supplied in the Tekscan program software and to compare its accuracy to the accuracy obtained with two user-defined calibration protocols. We evaluated the calibration accuracies for test loads within the low range, high range, and full range of the sensor. Our experimental setup used materials representing those found in standard prosthetic joints, i.e., metal against plastic. The Tekscan power calibration was the most accurate of the algorithms provided with the system software, with an overall rms error of 2.7% of the tested sensor range, whereas the linear calibrations resulted in an overall rms error of up to 24% of the tested range. The user-defined ten-point cubic calibration was almost five times more accurate, on average, than the power calibration over the full range, with an overall rms error of 0.6% of the tested range. The user-defined three-point quadratic calibration was almost twice as accurate as the Tekscan power calibration, but was sensitive to the calibration loads used. We recommend that investigators design their own calibration curves not only to improve accuracy but also to understand the range(s) of highest error and to choose the optimal points within the expected sensing range for calibration. Since output and sensor nonlinearity depend on the experimental protocol (sensor type, interface shape and materials, sensor range in use, loading method, etc.), sensor behavior should be investigated for each different application.

  3. High accuracy 3-D laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a mono-static staring 3-D laser radar based on gated viewing with range accuracy below 1 m at 10 m and 1 cm at 100. We use a high sensitivity, fast, intensified CCD camera, and a Nd:Yag passively Q-switched 32.4 kHz pulsed green laser at 532 nm. The CCD has 752x582 pixels. Camera...... shutter is controlled in steps of 100 ps. Camera delay is controlled in steps of 100 ps. Each laser pulse triggers the camera delay and shutter. A 3-D image is constructed from a sequence of 50-100 2-D reflectivity images, where each frame integrates about 700 laser pulses on the CCD. In 50 Hz video mode...

  4. Development of fabricating method for optical aspheric surface and fabricating method for high accuracy quadric surface mirror for solar furnace; Kogaku hikyumen no seisakuho no kaihatsu kara taiyoroyo koseido niji kyokumenkyo no sakuseiho made

    Energy Technology Data Exchange (ETDEWEB)

    Shishido, K. [Tohoku Gakuin Univ., Miyagi (Japan). Faculty of Engineering

    1996-03-29

    45 years have passed since the initiation of study on the fabricating method for optical aspheric surface. As examples of making prototypes for the `cam system,` fabrications of ellipsoidal surface mirror, parabolic mirror, segment type parabolic mirror, and particularly special asymmetric aspheric surface lens are quoted as successful cases. As regards the `link` system, a parabolic surface finishing machine for making matrices for soft formation of parabolic mirror segment glass was made on trial basis. Recently, a prototype of finishing machine for making a quadric surface finishing machine with higher accuracy was produced, which enabled preparation of more accurate matrices than in the past in the field of parabolic surface finishing machine, and actual ellipsoidal surface was machined by an ellipsoidal surface finishing machine. As regards solar furnace, study had been made to develop a method of producing a segment type glass mirror comprising a main mirror and a sub-mirror by a comparatively simple method and at high accuracy, and a promising result was obtained. 35 figs.

  5. Methodology for high accuracy contact angle measurement.

    Science.gov (United States)

    Kalantarian, A; David, R; Neumann, A W

    2009-12-15

    A new version of axisymmetric drop shape analysis (ADSA) called ADSA-NA (ADSA-no apex) was developed for measuring interfacial properties for drop configurations without an apex. ADSA-NA facilitates contact angle measurements on drops with a capillary protruding into the drop. Thus a much simpler experimental setup, not involving formation of a complete drop from below through a hole in the test surface, may be used. The contact angles of long-chained alkanes on a commercial fluoropolymer, Teflon AF 1600, were measured using the new method. A new numerical scheme was incorporated into the image processing to improve the location of the contact points of the liquid meniscus with the solid substrate to subpixel resolution. The images acquired in the experiments were also analyzed by a different drop shape technique called theoretical image fitting analysis-axisymmetric interfaces (TIFA-AI). The results were compared with literature values obtained by means of the standard ADSA for sessile drops with the apex. Comparison of the results from ADSA-NA with those from TIFA-AI and ADSA reveals that, with different numerical strategies and experimental setups, contact angles can be measured with an accuracy of less than 0.2 degrees. Contact angles and surface tensions measured from drops with no apex, i.e., by means of ADSA-NA and TIFA-AI, were considerably less scattered than those from complete drops with apex. ADSA-NA was also used to explore sources of improvement in contact angle resolution. It was found that using an accurate value of surface tension as an input enhances the accuracy of contact angle measurements.

  6. The use of low density high accuracy (LDHA) data for correction of high density low accuracy (HDLA) point cloud

    Science.gov (United States)

    Rak, Michal Bartosz; Wozniak, Adam; Mayer, J. R. R.

    2016-06-01

    Coordinate measuring techniques rely on computer processing of coordinate values of points gathered from physical surfaces using contact or non-contact methods. Contact measurements are characterized by low density and high accuracy. On the other hand optical methods gather high density data of the whole object in a short time but with accuracy at least one order of magnitude lower than for contact measurements. Thus the drawback of contact methods is low density of data, while for non-contact methods it is low accuracy. In this paper a method for fusion of data from two measurements of fundamentally different nature: high density low accuracy (HDLA) and low density high accuracy (LDHA) is presented to overcome the limitations of both measuring methods. In the proposed method the concept of virtual markers is used to find a representation of pairs of corresponding characteristic points in both sets of data. In each pair the coordinates of the point from contact measurements is treated as a reference for the corresponding point from non-contact measurement. Transformation enabling displacement of characteristic points from optical measurement to their match from contact measurements is determined and applied to the whole point cloud. The efficiency of the proposed algorithm was evaluated by comparison with data from a coordinate measuring machine (CMM). Three surfaces were used for this evaluation: plane, turbine blade and engine cover. For the planar surface the achieved improvement was of around 200 μm. Similar results were obtained for the turbine blade but for the engine cover the improvement was smaller. For both freeform surfaces the improvement was higher for raw data than for data after creation of mesh of triangles.

  7. High Accuracy Wavelength Calibration For A Scanning Visible Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Filippo Scotti and Ronald Bell

    2010-07-29

    Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤ 0.2Â. An automated calibration for a scanning spectrometer has been developed to achieve a high wavelength accuracy overr the visible spectrum, stable over time and environmental conditions, without the need to recalibrate after each grating movement. The method fits all relevant spectrometer paraameters using multiple calibration spectra. With a steping-motor controlled sine-drive, accuracies of ~0.025 Â have been demonstrated. With the addition of high resolution (0.075 aresec) optical encoder on the grading stage, greater precision (~0.005 Â) is possible, allowing absolute velocity measurements with ~0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

  8. Compensation of motion error in a high accuracy AFM

    Science.gov (United States)

    Cui, Yuguo; Arai, Yoshikazu; He, Gaofa; Asai, Takemi; Gao, Wei

    2008-10-01

    An atomic force microscope (AFM) system is used for large-area measurement with a spiral scanning strategy, which is composed of an air slide, an air spindle and a probe unit. The motion error which is brought from the air slide and the air spindle will increase with the increasing of the measurement area. Then the measurement accuracy will decrease. In order to achieve a high speed and high accuracy measurement, the probe scans along X-direction with constant height mode driven by the air slide, and at the same time, based on the change way of the motion error, it moves along Zdirection conducted by piezoactuator. According to the above method of error compensation, the profile measurement experiment of a micro-structured surface has been carried out. The experimental result shows that this method is effective for eliminating motion error, and it can achieve high speed and precision measurement of micro-structured surface.

  9. High accuracy GNSS based navigation in GEO

    Science.gov (United States)

    Capuano, Vincenzo; Shehaj, Endrit; Blunt, Paul; Botteron, Cyril; Farine, Pierre-André

    2017-07-01

    Although significant improvements in efficiency and performance of communication satellites have been achieved in the past decades, it is expected that the demand for new platforms in Geostationary Orbit (GEO) and for the On-Orbit Servicing (OOS) on the existing ones will continue to rise. Indeed, the GEO orbit is used for many applications including direct broadcast as well as communications. At the same time, Global Navigation Satellites System (GNSS), originally designed for land, maritime and air applications, has been successfully used as navigation system in Low Earth Orbit (LEO) and its further utilization for navigation of geosynchronous satellites becomes a viable alternative offering many advantages over present ground based methods. Following our previous studies of GNSS signal characteristics in Medium Earth Orbit (MEO), GEO and beyond, in this research we specifically investigate the processing of different GNSS signals, with the goal to determine the best navigation performance they can provide in a GEO mission. Firstly, a detailed selection among different GNSS signals and different combinations of them is discussed, taking into consideration the L1 and L5 frequency bands, and the GPS and Galileo constellations. Then, the implementation of an Orbital Filter is summarized, which adaptively fuses the GN1SS observations with an accurate orbital forces model. Finally, simulation tests of the navigation performance achievable by processing the selected combination of GNSS signals are carried out. The results obtained show an achievable positioning accuracy of less than one meter. In addition, hardware-in-the-loop tests are presented using a COTS receiver connected to our GNSS Spirent simulator, in order to collect real-time hardware-in-the-loop observations and process them by the proposed navigation module.

  10. A fast RCS accuracy assessment method for passive radar calibrators

    Science.gov (United States)

    Zhou, Yongsheng; Li, Chuanrong; Tang, Lingli; Ma, Lingling; Liu, QI

    2016-10-01

    In microwave radar radiometric calibration, the corner reflector acts as the standard reference target but its structure is usually deformed during the transportation and installation, or deformed by wind and gravity while permanently installed outdoor, which will decrease the RCS accuracy and therefore the radiometric calibration accuracy. A fast RCS accuracy measurement method based on 3-D measuring instrument and RCS simulation was proposed in this paper for tracking the characteristic variation of the corner reflector. In the first step, RCS simulation algorithm was selected and its simulation accuracy was assessed. In the second step, the 3-D measuring instrument was selected and its measuring accuracy was evaluated. Once the accuracy of the selected RCS simulation algorithm and 3-D measuring instrument was satisfied for the RCS accuracy assessment, the 3-D structure of the corner reflector would be obtained by the 3-D measuring instrument, and then the RCSs of the obtained 3-D structure and corresponding ideal structure would be calculated respectively based on the selected RCS simulation algorithm. The final RCS accuracy was the absolute difference of the two RCS calculation results. The advantage of the proposed method was that it could be applied outdoor easily, avoiding the correlation among the plate edge length error, plate orthogonality error, plate curvature error. The accuracy of this method is higher than the method using distortion equation. In the end of the paper, a measurement example was presented in order to show the performance of the proposed method.

  11. Improved Fast Fourier Transform Based Method for Code Accuracy Quantification

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Tae Wook; Jeong, Jae Jun [Pusan National University, Busan (Korea, Republic of); Choi, Ki Yong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The capability of the proposed method is discussed. In this study, the limitations of the FFTBM were analyzed. The FFTBM produces quantitatively different results due to its frequency dependence. Because the problem is intensified by including a lot of high frequency components, a new method using a reduced cut-off frequency was proposed. The results of the proposed method show that the shortcomings of FFTBM are considerably relieved. Among them, the fast Fourier transform based method (FFTBM) introduced in 1990 has been widely used to evaluate a code uncertainty or accuracy. Prosek et al., (2008) identified its drawbacks, the so-called 'edge effect'. To overcome the problems, an improved FFTBM by signal mirroring (FFTBM-SM) was proposed and it has been used up to now. In spite of the improvement, the FFTBM-SM yielded different accuracy depending on the frequency components of a parameter, such as pressure, temperature and mass flow rate. Therefore, it is necessary to reduce the frequency dependence of the FFTBMs. In this study, the deficiencies of the present FFTBMs are analyzed and a new method is proposed to mitigate its frequency dependence.

  12. A SINGLE STEP SCHEME WITH HIGH ACCURACY FOR PARABOLIC PROBLEM

    Institute of Scientific and Technical Information of China (English)

    陈传淼; 胡志刚

    2001-01-01

    A single step scheme with high accuracy for solving parabolic problem is proposed. It is shown that this scheme possesses good stability and fourth order accuracy with respect to both time and space variables, which are superconvergent.

  13. Testing an Automated Accuracy Assessment Method on Bibliographic Data

    Directory of Open Access Journals (Sweden)

    Marlies Olensky

    2014-12-01

    Full Text Available This study investigates automated data accuracy assessment as described in data quality literature for its suitability to assess bibliographic data. The data samples comprise the publications of two Nobel Prize winners in the field of Chemistry for a 10-year-publication period retrieved from the two bibliometric data sources, Web of Science and Scopus. The bibliographic records are assessed against the original publication (gold standard and an automatic assessment method is compared to a manual one. The results show that the manual assessment method reflects truer accuracy scores. The automated assessment method would need to be extended by additional rules that reflect specific characteristics of bibliographic data. Both data sources had higher accuracy scores per field than accumulated per record. This study contributes to the research on finding a standardized assessment method of bibliographic data accuracy as well as defining the impact of data accuracy on the citation matching process.

  14. Estimated Accuracy of Three Common Trajectory Statistical Methods

    Science.gov (United States)

    Kabashnikov, Vitaliy P.; Chaikovsky, Anatoli P.; Kucsera, Tom L.; Metelskaya, Natalia S.

    2011-01-01

    and 0.5 0.95 for the decay time of 12 h. The best results of source reconstruction can be expected for the trace substances with a decay time on the order of several days. Although the methods considered in this paper do not guarantee high accuracy they are computationally simple and fast. Using the TSMs in optimum conditions and taking into account the range of uncertainties, one can obtain a first hint on potential source areas.

  15. Accuracy Enhancement of Inertial Sensors Utilizing High Resolution Spectral Analysis

    Directory of Open Access Journals (Sweden)

    Michael Korenberg

    2012-08-01

    Full Text Available In both military and civilian applications, the inertial navigation system (INS and the global positioning system (GPS are two complementary technologies that can be integrated to provide reliable positioning and navigation information for land vehicles. The accuracy enhancement of INS sensors and the integration of INS with GPS are the subjects of widespread research. Wavelet de-noising of INS sensors has had limited success in removing the long-term (low-frequency inertial sensor errors. The primary objective of this research is to develop a novel inertial sensor accuracy enhancement technique that can remove both short-term and long-term error components from inertial sensor measurements prior to INS mechanization and INS/GPS integration. A high resolution spectral analysis technique called the fast orthogonal search (FOS algorithm is used to accurately model the low frequency range of the spectrum, which includes the vehicle motion dynamics and inertial sensor errors. FOS models the spectral components with the most energy first and uses an adaptive threshold to stop adding frequency terms when fitting a term does not reduce the mean squared error more than fitting white noise. The proposed method was developed, tested and validated through road test experiments involving both low-end tactical grade and low cost MEMS-based inertial systems. The results demonstrate that in most cases the position accuracy during GPS outages using FOS de-noised data is superior to the position accuracy using wavelet de-noising.

  16. High accuracy and visibility-consistent dense multiview stereo.

    Science.gov (United States)

    Vu, Hoang-Hiep; Labatut, Patrick; Pons, Jean-Philippe; Keriven, Renaud

    2012-05-01

    Since the initial comparison of Seitz et al., the accuracy of dense multiview stereovision methods has been increasing steadily. A number of limitations, however, make most of these methods not suitable to outdoor scenes taken under uncontrolled imaging conditions. The present work consists of a complete dense multiview stereo pipeline which circumvents these limitations, being able to handle large-scale scenes without sacrificing accuracy. Highly detailed reconstructions are produced within very reasonable time thanks to two key stages in our pipeline: a minimum s-t cut optimization over an adaptive domain that robustly and efficiently filters a quasidense point cloud from outliers and reconstructs an initial surface by integrating visibility constraints, followed by a mesh-based variational refinement that captures small details, smartly handling photo-consistency, regularization, and adaptive resolution. The pipeline has been tested over a wide range of scenes: from classic compact objects taken in a laboratory setting, to outdoor architectural scenes, landscapes, and cultural heritage sites. The accuracy of its reconstructions has also been measured on the dense multiview benchmark proposed by Strecha et al., showing the results to compare more than favorably with the current state-of-the-art methods.

  17. Navigation message designing with high accuracy for NAV

    Institute of Scientific and Technical Information of China (English)

    Wang Luxiao; Huang Zhigang; Zhao Yun

    2014-01-01

    Navigation message designing with high accuracy guarantee is the key to efficient navi-gation message distribution in the global navigation satellite system (GNSS). Developing high accu-racy-aware navigation message designing algorithms is an important topic. This paper investigates the high-accuracy navigation message designing problem with the message structure unchanged. The contributions made in this paper include a heuristic that employs the concept of the estimated range deviation (ERD) to improve the existing well-known navigation message on L1 frequency (NAV) of global positioning system (GPS) for good accuracy service; a numerical analysis approximation method (NAAM) to evaluate the range error due to truncation (RET) of different navigation messages; and a basic positioning parameters designing algorithm in the limited space allocation. Based on the predicted ultra-rapid data from the ultra-rapid data from the international GPS service for geodynamic (IGU), ERDs are generated in real time for error correction. Simulations show that the algorithms developed in this paper are general and flexible, and thus are applicable to NAV improvement and other navigation message designs.

  18. High accuracy & long timescale light curves

    Directory of Open Access Journals (Sweden)

    Hodgkin S.

    2013-04-01

    Full Text Available We present a theoretical analysis of the optical light curves (LCs for short-period high-mass transiting extrasolar planet systems. Our method considers the primary transit, the secondary eclipse, and the overall phase shape of the LC between the occultations. Phase variations arise from (i reflected and thermally emitted light by the planet, (ii the ellipsoidal shape of the star due to the gravitational pull of the planet, and (iii the Doppler shift of the stellar light as the star orbits the center of mass of the system. Our full model of the out-of-eclipse variations contains information about the planetary mass, orbital eccentricity, the orientation of periastron and the planet's albedo. For a range of hypothetical systems we demonstrate that the ellipsoidal variations (ii. can be large enough to be distinguished from the remaining components and that this effect can be used to constrain the planet's mass. As an example we presend KOI-13b (candidate exoplanet system included in the September 2011 Kepler data release. The Kepler light curve shows both primary and secondary eclipses, as well as significant out-of-eclipse light curve variations. We model the relative contributions from (i thermal emission from the companion, (ii planetary reflected light, (iii doppler beaming, and (iv ellipsoidal variations in the host-star arising from the tidal distortion of the host star by its companion. Our analysis, based on the light curve alone, enables us to constrain the mass of the KOI-13.01 companion to be MC = 8.3 ± 1.25 MJ and thus demonstrates that the transiting companion is a planet. The teqnique is useful for current and future space missions such as Kepler and PLATO.

  19. Spatial augmented reality based high accuracy human face projection

    Science.gov (United States)

    Li, Dong; Xie, Jinghui; Li, Yufeng; Weng, Dongdong; Liu, Yue

    2015-08-01

    This paper discusses the imaging principles and the technical difficulties of spatial augmented reality based human face projection. A novel geometry correction method is proposed to realize fast, high-accuracy face model projection. Using a depth camera to reconstruct the projected object, the relative position from the rendered model to the projector can be accessed and the initial projection image is generated. Then the projected image is distorted by using Bezier interpolation to guarantee that the projected texture matches with the object surface. The proposed method is under a simple process flow and can achieve high perception registration of virtual and real object. In addition, this method has a good performance in the condition that the reconstructed model is not exactly same with the rendered virtual model which extends its application area in the spatial augmented reality based human face projection.

  20. Compact, High Accuracy CO2 Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovative Research Phase II proposal seeks to develop a low cost, robust, highly precise and accurate CO2 monitoring system. This system will...

  1. Compact, High Accuracy CO2 Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovative Research Phase I proposal seeks to develop a low cost, robust, highly precise and accurate CO2 monitoring system. This system will...

  2. High speed high dynamic range high accuracy measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Deibele, Craig E.; Curry, Douglas E.; Dickson, Richard W.; Xie, Zaipeng

    2016-11-29

    A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

  3. High accuracy in silico sulfotransferase models.

    Science.gov (United States)

    Cook, Ian; Wang, Ting; Falany, Charles N; Leyh, Thomas S

    2013-11-29

    Predicting enzymatic behavior in silico is an integral part of our efforts to understand biology. Hundreds of millions of compounds lie in targeted in silico libraries waiting for their metabolic potential to be discovered. In silico "enzymes" capable of accurately determining whether compounds can inhibit or react is often the missing piece in this endeavor. This problem has now been solved for the cytosolic sulfotransferases (SULTs). SULTs regulate the bioactivities of thousands of compounds--endogenous metabolites, drugs and other xenobiotics--by transferring the sulfuryl moiety (SO3) from 3'-phosphoadenosine 5'-phosphosulfate to the hydroxyls and primary amines of these acceptors. SULT1A1 and 2A1 catalyze the majority of sulfation that occurs during human Phase II metabolism. Here, recent insights into the structure and dynamics of SULT binding and reactivity are incorporated into in silico models of 1A1 and 2A1 that are used to identify substrates and inhibitors in a structurally diverse set of 1,455 high value compounds: the FDA-approved small molecule drugs. The SULT1A1 models predict 76 substrates. Of these, 53 were known substrates. Of the remaining 23, 21 were tested, and all were sulfated. The SULT2A1 models predict 22 substrates, 14 of which are known substrates. Of the remaining 8, 4 were tested, and all are substrates. The models proved to be 100% accurate in identifying substrates and made no false predictions at Kd thresholds of 100 μM. In total, 23 "new" drug substrates were identified, and new linkages to drug inhibitors are predicted. It now appears to be possible to accurately predict Phase II sulfonation in silico.

  4. An accuracy measurement method for star trackers based on direct astronomic observation

    Science.gov (United States)

    Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping

    2016-01-01

    Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers. PMID:26948412

  5. An accuracy measurement method for star trackers based on direct astronomic observation

    Science.gov (United States)

    Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping

    2016-03-01

    Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers.

  6. High Accuracy and Fast Alignment Method for Single-axial Rotation SINS%一种单轴旋转捷联惯导系统高精度快速对准方法

    Institute of Scientific and Technical Information of China (English)

    刘永红; 刘明雍; 谢波

    2015-01-01

    It needs prolonging the coarse alignment time to improve the accuracy of the coarse alignment under the rocking condition.Otherwise,it can’t control the azimuth error in the small range,then the fine alignment will converge slowly.To solve this problem,a high accuracy and fast alignment method which uses reverse navigation technology is put forward for rotary SINS.This method prolongs the coarse alignment time mostly,then saves the data of SINS to carry on fine alignment.It use the data of alignmet sufficiently and improve the alignment accuracy mostly in certain alignment time.The result of test indicated this method is not only reduce amount of calculation,but also simplify the algorithm ,it can also achieve fast alignment of rotary SINS and can acquire high accuracy.All this characteristics prove that the method is valuable in engineering application.%在晃动条件下,需要延长粗对准时间来提高粗对准精度。否则,无法把方位误差控制在小角度范围内,从而导致后续的精对准无法快速收敛。针对这个问题,提出了一种利用逆向导航技术的单轴旋转捷联惯导系统高精度快速对准方法,最大限度地延长粗对准时间,并把采样数据存储下来,进行逆向精对准。这种算法充分地利用了对准数据,在固定对准时间内极大程度的提高了对准精度。试验证明,这种算法计算量小,算法简单,能实现单轴旋转捷联惯导系统高精度快速对准,且对准精度高,具有一定的工程应用价值。

  7. High accuracy autonomous navigation using the global positioning system (GPS)

    Science.gov (United States)

    Truong, Son H.; Hart, Roger C.; Shoan, Wendy C.; Wood, Terri; Long, Anne C.; Oza, Dipak H.; Lee, Taesul

    1997-01-01

    The application of global positioning system (GPS) technology to the improvement of the accuracy and economy of spacecraft navigation, is reported. High-accuracy autonomous navigation algorithms are currently being qualified in conjunction with the GPS attitude determination flyer (GADFLY) experiment for the small satellite technology initiative Lewis spacecraft. Preflight performance assessments indicated that these algorithms are able to provide a real time total position accuracy of better than 10 m and a velocity accuracy of better than 0.01 m/s, with selective availability at typical levels. It is expected that the position accuracy will be increased to 2 m if corrections are provided by the GPS wide area augmentation system.

  8. Method for Improving Indoor Positioning Accuracy Using Extended Kalman Filter

    Directory of Open Access Journals (Sweden)

    Seoung-Hyeon Lee

    2016-01-01

    Full Text Available Beacons using bluetooth low-energy (BLE technology have emerged as a new paradigm of indoor positioning service (IPS because of their advantages such as low power consumption, miniaturization, wide signal range, and low cost. However, the beacon performance is poor in terms of the indoor positioning accuracy because of noise, motion, and fading, all of which are characteristics of a bluetooth signal and depend on the installation location. Therefore, it is necessary to improve the accuracy of beacon-based indoor positioning technology by fusing it with existing indoor positioning technology, which uses Wi-Fi, ZigBee, and so forth. This study proposes a beacon-based indoor positioning method using an extended Kalman filter that recursively processes input data including noise. After defining the movement of a smartphone on a flat two-dimensional surface, it was assumed that the beacon signal is nonlinear. Then, the standard deviation and properties of the beacon signal were analyzed. According to the analysis results, an extended Kalman filter was designed and the accuracy of the smartphone’s indoor position was analyzed through simulations and tests. The proposed technique achieved good indoor positioning accuracy, with errors of 0.26 m and 0.28 m from the average x- and y-coordinates, respectively, based solely on the beacon signal.

  9. Stability and Accuracy Analysis for Taylor Series Numerical Method

    Institute of Scientific and Technical Information of China (English)

    赵丽滨; 姚振汉; 王寿梅

    2004-01-01

    The Taylor series numerical method (TSNM) is a time integration method for solving problems in structural dynamics. In this paper, a detailed analysis of the stability behavior and accuracy characteristics of this method is given. It is proven by a spectral decomposition method that TSNM is conditionally stable and belongs to the category of explicit time integration methods. By a similar analysis, the characteristic indicators of time integration methods, the percentage period elongation and the amplitude decay of TSNM, are derived in a closed form. The analysis plays an important role in implementing a procedure for automatic searching and finding convergence radii of TSNM. Finally, a linear single degree of freedom undamped system is analyzed to test the properties of the method.

  10. Photogrammetric methods applied to Svalbard glaciers: accuracies and challenges

    Directory of Open Access Journals (Sweden)

    Trond Eiken

    2012-06-01

    Full Text Available Use of digital images is expanding as a tool for glacier monitoring, and small-format time-lapse cameras are increasingly being used for glacier monitoring of fast-flowing glaciers. Stereoscopic imagery is preferable since it yields direct displacement results but stereo photogrammetry has more requirements regarding geometry in set-up and control points, as well as the additional cost of another complete camera system. We investigate a combination of methods to achieve satisfactory control of accuracy with resulting significant day-to-day velocity variations ranging from 1.5–4 m day−1 made at a distance of 2 km. Validation of results was made by comparing different methods, partly using the same image material, but also in combination with aerial and satellite images. Monoscopic results can also be used to gain continuity in a stereo data set when geometry or visibility is poor. We also explore the use of ordinary photographs taken from airliners for compilation of orthoimages as a potential low cost method for detection of sudden changes. The method, showing some tens of metres accuracy, was verified for monitoring velocities and front positions during a glacier surge and was also used to validate monoscopic time-lapse images.

  11. Influence of spatial temperature distribution on high accuracy interferometric metrology

    Science.gov (United States)

    Gu, Yongqiang; Miao, Erlong; Yan, Feng; Zhang, Jian; Yang, Huaijiang

    2010-10-01

    We calculate the influence of temperature change on the refractive index of air, establish a model of air temperature distribution and analyze the effect of different temperature distribution on the high accuracy interferometric metrology. First, a revised Edlen formula is employed to acquire the relation between temperature and refractive index of air, followed by introducing the fixed temperature gradient distribution among the spatial grid within the optical cavity between the reference flat and the test flat of the Fizeau interferometer, accompanied by a temperature change random function within each grid. Finally, all the rays through the air layer with different incident angles are traced by Matlab program in order to obtain the final output position, angle and OPD for each ray. The influence of different temperature distribution and the length of the optical cavity in on the testing accuracy can be analyzed through the RMS value that results from repeatable rays tracing. As a result, the horizontal distribution (vertical to optical axis) has a large effect on the testing accuracy. Thus, to realize the high accuracy figure metrology, the horizontal distribution of temperature must be rigorously controlled as well as to shorten the length of the optical cavity to a large extent. The results from our simulation are of great significant for the accuracy analysis of interferometric testing and the research of manufacturing a interferometer.

  12. Method for improving accuracy in full evaporation headspace analysis.

    Science.gov (United States)

    Xie, Wei-Qi; Chai, Xin-Sheng

    2017-03-21

    We report a new headspace analytical method in which multiple headspace extraction is incorporated with the full evaporation technique. The pressure uncertainty caused by the solid content change in the samples has a great impact to the measurement accuracy in the conventional full evaporation headspace analysis. The results (using ethanol solution as the model sample) showed that the present technique is effective to minimize such a problem. The proposed full evaporation multiple headspace extraction analysis technique is also automated and practical, and which could greatly broaden the applications of the full-evaporation-based headspace analysis. This article is protected by copyright. All rights reserved.

  13. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1998-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with realtime information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate flight

  14. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1999-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with real-time information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate lligh

  15. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1999-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with real-time information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate lligh

  16. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1998-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with realtime information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate flight

  17. DIPSY, a low-cost GPS application with high accuracy

    NARCIS (Netherlands)

    Heijden, W.F.M. van der

    1999-01-01

    To improve the control of unmanned aircraft flying out of visual range, the controller needs to be provided with real-time information about the position and behaviour of the drone during the flight. The position of the drone has to be presented with a relative high accuracy to obtain accurate

  18. Accuracy of multi-trait genomic selection using different methods

    Directory of Open Access Journals (Sweden)

    Veerkamp Roel F

    2011-07-01

    Full Text Available Abstract Background Genomic selection has become a very important tool in animal genetics and is rapidly emerging in plant genetics. It holds the promise to be particularly beneficial to select for traits that are difficult or expensive to measure, such as traits that are measured in one environment and selected for in another environment. The objective of this paper was to develop three models that would permit multi-trait genomic selection by combining scarcely recorded traits with genetically correlated indicator traits, and to compare their performance to single-trait models, using simulated datasets. Methods Three (SNP Single Nucleotide Polymorphism based models were used. Model G and BCπ0 assumed that contributed (covariances of all SNP are equal. Model BSSVS sampled SNP effects from a distribution with large (or small effects to model SNP that are (or not associated with a quantitative trait locus. For reasons of comparison, model A including pedigree but not SNP information was fitted as well. Results In terms of accuracies for animals without phenotypes, the models generally ranked as follows: BSSVS > BCπ0 > G > > A. Using multi-trait SNP-based models, the accuracy for juvenile animals without any phenotypes increased up to 0.10. For animals with phenotypes on an indicator trait only, accuracy increased up to 0.03 and 0.14, for genetic correlations with the evaluated trait of 0.25 and 0.75, respectively. Conclusions When the indicator trait had a genetic correlation lower than 0.5 with the trait of interest in our simulated data, the accuracy was higher if genotypes rather than phenotypes were obtained for the indicator trait. However, when genetic correlations were higher than 0.5, using an indicator trait led to higher accuracies for selection candidates. For different combinations of traits, the level of genetic correlation below which genotyping selection candidates is more effective than obtaining phenotypes for an indicator

  19. Key technologies for high-accuracy large mesh antenna reflectors

    Science.gov (United States)

    Meguro, Akira; Harada, Satoshi; Watanabe, Mitsunobu

    2003-12-01

    Nippon Telephone and Telegram Corporation (NTT) continues to develop the modular mesh-type deployable antenna. Antenna diameter can be changed from 5 m to about 20 m by changing the number of modules used with surface accuracy better than 2.4 mm RMS (including all error factors) with sufficient deployment reliability. Key technologies are the antenna's structural design, the deployment mechanism, the design tool, the analysis tool, and modularized testing/evaluation methods. This paper describes our beam steering mechanism. Tests show that it yields a beam pointing accuracy of better than 0.1°. Based on the S-band modular mesh antenna reflector, the surface accuracy degradation factors that must be considered in designing the new antenna are partially identified. The influence of modular connection errors on surface accuracy is quantitatively estimated. Our analysis tool SPADE is extended to include the addition of joint gaps. The addition of gaps allows non-linear vibration characteristics due to gapping in deployment hinges to be calculated. We intend to design a new type of mesh antenna reflector. Our new goal is an antenna for Ku or Ka band satellite communication. For this mission, the surface shape must be 5 times more accurate than is required for an S-band antenna.

  20. Why is a high accuracy needed in dosimetry. [Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lanzl, L.H.

    1976-01-01

    Dose and exposure intercomparisons on a national or international basis have become an important component of quality assurance in the practice of good radiotherapy. A high degree of accuracy of ..gamma.. and x radiation dosimetry is essential in our international society, where medical information is so readily exchanged and used. The value of accurate dosimetry lies mainly in the avoidance of complications in normal tissue and an optimal degree of tumor control.

  1. High Accuracy, Miniature Pressure Sensor for Very High Temperatures Project

    Data.gov (United States)

    National Aeronautics and Space Administration — SiWave proposes to develop a compact, low-cost MEMS-based pressure sensor for very high temperatures and low pressures in hypersonic wind tunnels. Most currently...

  2. Relative accuracy of three common methods of parentage analysis in natural populations.

    Science.gov (United States)

    Harrison, Hugo B; Saenz-Agudelo, Pablo; Planes, Serge; Jones, Geoffrey P; Berumen, Michael L

    2013-02-01

    Parentage studies and family reconstructions have become increasingly popular for investigating a range of evolutionary, ecological and behavioural processes in natural populations. However, a number of different assignment methods have emerged in common use and the accuracy of each may differ in relation to the number of loci examined, allelic diversity, incomplete sampling of all candidate parents and the presence of genotyping errors. Here, we examine how these factors affect the accuracy of three popular parentage inference methods (colony, famoz and an exclusion-Bayes' theorem approach by Christie (Molecular Ecology Resources, 2010a, 10, 115) to resolve true parent-offspring pairs using simulated data. Our findings demonstrate that accuracy increases with the number and diversity of loci. These were clearly the most important factors in obtaining accurate assignments explaining 75-90% of variance in overall accuracy across 60 simulated scenarios. Furthermore, the proportion of candidate parents sampled had a small but significant impact on the susceptibility of each method to either false-positive or false-negative assignments. Within the range of values simulated, colony outperformed FaMoz, which outperformed the exclusion-Bayes' theorem method. However, with 20 or more highly polymorphic loci, all methods could be applied with confidence. Our results show that for parentage inference in natural populations, careful consideration of the number and quality of markers will increase the accuracy of assignments and mitigate the effects of incomplete sampling of parental populations.

  3. Relative accuracy of three common methods of parentage analysis in natural populations

    KAUST Repository

    Harrison, Hugo B.

    2012-12-27

    Parentage studies and family reconstructions have become increasingly popular for investigating a range of evolutionary, ecological and behavioural processes in natural populations. However, a number of different assignment methods have emerged in common use and the accuracy of each may differ in relation to the number of loci examined, allelic diversity, incomplete sampling of all candidate parents and the presence of genotyping errors. Here, we examine how these factors affect the accuracy of three popular parentage inference methods (colony, famoz and an exclusion-Bayes\\' theorem approach by Christie (Molecular Ecology Resources, 2010a, 10, 115) to resolve true parent-offspring pairs using simulated data. Our findings demonstrate that accuracy increases with the number and diversity of loci. These were clearly the most important factors in obtaining accurate assignments explaining 75-90% of variance in overall accuracy across 60 simulated scenarios. Furthermore, the proportion of candidate parents sampled had a small but significant impact on the susceptibility of each method to either false-positive or false-negative assignments. Within the range of values simulated, colony outperformed FaMoz, which outperformed the exclusion-Bayes\\' theorem method. However, with 20 or more highly polymorphic loci, all methods could be applied with confidence. Our results show that for parentage inference in natural populations, careful consideration of the number and quality of markers will increase the accuracy of assignments and mitigate the effects of incomplete sampling of parental populations. © 2012 Blackwell Publishing Ltd.

  4. High Accuracy Monocular SFM and Scale Correction for Autonomous Driving.

    Science.gov (United States)

    Song, Shiyu; Chandraker, Manmohan; Guest, Clark C

    2016-04-01

    We present a real-time monocular visual odometry system that achieves high accuracy in real-world autonomous driving applications. First, we demonstrate robust monocular SFM that exploits multithreading to handle driving scenes with large motions and rapidly changing imagery. To correct for scale drift, we use known height of the camera from the ground plane. Our second contribution is a novel data-driven mechanism for cue combination that allows highly accurate ground plane estimation by adapting observation covariances of multiple cues, such as sparse feature matching and dense inter-frame stereo, based on their relative confidences inferred from visual data on a per-frame basis. Finally, we demonstrate extensive benchmark performance and comparisons on the challenging KITTI dataset, achieving accuracy comparable to stereo and exceeding prior monocular systems. Our SFM system is optimized to output pose within 50 ms in the worst case, while average case operation is over 30 fps. Our framework also significantly boosts the accuracy of applications like object localization that rely on the ground plane.

  5. On the Accuracy of RAS Method in an Emergent Economy

    Directory of Open Access Journals (Sweden)

    Emilian Dobrescu

    2012-06-01

    Full Text Available The goal of this paper is to check the applicability of RAS procedure (in its conventional definition on statistical series of an emergent economy, as the Romanian one. As it is known, during transition from centrally planned system to market mechanisms, the society passes through deep restructuration, consisting in complex institutional changes, technological shifts, sectoral reallocation of productive factors, which continuously affected the input-output technical coefficients. Testing the RAS algorithm on such a volatile framework is a notable search challenge. Our empirical experiment is based on annual input-output tables for two decades (1989- 2008. In order to easier manipulate the available data base, the extended classification of economic activities containing 105 branches has been aggregated into 10 sectors. For each year, two (10x10 matrices: aij (statistically recorded technical coefficients and raij (the same coefficients estimated using RAS method were computed. The paper is organized in three sections. The first discusses several methodological issues of this algorithm. It also evaluates the differences between matrices aij and raij, involving both categories of accuracy measures - either the “cell-by-cell” comparison or the aggregated indicators. The second section extensively examines these measures, the presentation being systematized sectorally. Such an approach allows revealing specificities of different branches in their inter-industry co-operation. The third section sketches an overview of the obtained results and extracts some conclusions related to the problems that arise in the application of RAS method.

  6. Diagnostic accuracy of existing methods for identifying diabetic foot ulcers from inpatient and outpatient datasets

    Directory of Open Access Journals (Sweden)

    Budiman-Mak Elly

    2010-11-01

    Full Text Available Abstract Background As the number of persons with diabetes is projected to double in the next 25 years in the US, an accurate method of identifying diabetic foot ulcers in population-based data sources are ever more important for disease surveillance and public health purposes. The objectives of this study are to evaluate the accuracy of existing methods and to propose a new method. Methods Four existing methods were used to identify all patients diagnosed with a foot ulcer in a Department of Veterans Affairs (VA hospital from the inpatient and outpatient datasets for 2003. Their electronic medical records were reviewed to verify whether the medical records positively indicate presence of a diabetic foot ulcer in diagnoses, medical assessments, or consults. For each method, five measures of accuracy and agreement were evaluated using data from medical records as the gold standard. Results Our medical record reviews show that all methods had sensitivity > 92% but their specificity varied substantially between 74% and 91%. A method used in Harrington et al. (2004 was the most accurate with 94% sensitivity and 91% specificity and produced an annual prevalence of 3.3% among VA users with diabetes nationwide. A new and simpler method consisting of two codes (707.1× and 707.9 shows an equally good accuracy with 93% sensitivity and 91% specificity and 3.1% prevalence. Conclusions Our results indicate that the Harrington and New methods are highly comparable and accurate. We recommend the Harrington method for its accuracy and the New method for its simplicity and comparable accuracy.

  7. Diagnostic methods I: sensitivity, specificity, and other measures of accuracy

    NARCIS (Netherlands)

    K.J. van Stralen; V.S. Stel; J.B. Reitsma; F.W. Dekker; C. Zoccali; K.J. Jager

    2009-01-01

    For most physicians, use of diagnostic tests is part of daily routine. This paper focuses on their usefulness by explaining the different measures of accuracy, the interpretation of test results, and the implementation of a diagnostic strategy. Measures of accuracy include sensitivity and specificit

  8. Analysis on the reconstruction accuracy of the Fitch method for inferring ancestral states

    Directory of Open Access Journals (Sweden)

    Grünewald Stefan

    2011-01-01

    Full Text Available Abstract Background As one of the most widely used parsimony methods for ancestral reconstruction, the Fitch method minimizes the total number of hypothetical substitutions along all branches of a tree to explain the evolution of a character. Due to the extensive usage of this method, it has become a scientific endeavor in recent years to study the reconstruction accuracies of the Fitch method. However, most studies are restricted to 2-state evolutionary models and a study for higher-state models is needed since DNA sequences take the format of 4-state series and protein sequences even have 20 states. Results In this paper, the ambiguous and unambiguous reconstruction accuracy of the Fitch method are studied for N-state evolutionary models. Given an arbitrary phylogenetic tree, a recurrence system is first presented to calculate iteratively the two accuracies. As complete binary tree and comb-shaped tree are the two extremal evolutionary tree topologies according to balance, we focus on the reconstruction accuracies on these two topologies and analyze their asymptotic properties. Then, 1000 Yule trees with 1024 leaves are generated and analyzed to simulate real evolutionary scenarios. It is known that more taxa not necessarily increase the reconstruction accuracies under 2-state models. The result under N-state models is also tested. Conclusions In a large tree with many leaves, the reconstruction accuracies of using all taxa are sometimes less than those of using a leaf subset under N-state models. For complete binary trees, there always exists an equilibrium interval [a, b] of conservation probability, in which the limiting ambiguous reconstruction accuracy equals to the probability of randomly picking a state. The value b decreases with the increase of the number of states, and it seems to converge. When the conservation probability is greater than b, the reconstruction accuracies of the Fitch method increase rapidly. The reconstruction

  9. Accuracy of Wind Prediction Methods in the California Sea Breeze

    Science.gov (United States)

    Sumers, B. D.; Dvorak, M. J.; Ten Hoeve, J. E.; Jacobson, M. Z.

    2010-12-01

    In this study, we investigate the accuracy of measure-correlate-predict (MCP) algorithms and log law/power law scaling using data from two tall towers in coastal environments. We find that MCP algorithms accurately predict sea breeze winds and that log law/power law scaling methods struggle to predict 50-meter wind speeds. MCP methods have received significant attention as the wind industry has grown and the ability to accurately characterize the wind resource has become valuable. These methods are used to produce longer-term wind speed records from short-term measurement campaigns. A correlation is developed between the “target site,” where the developer is interested in building wind turbines, and a “reference site,” where long-term wind data is available. Up to twenty years of prior wind speeds are then are predicted. In this study, two existing MCP methods - linear regression and Mortimer’s method - are applied to predict 50-meter wind speeds at sites in the Salinas Valley and Redwood City, CA. The predictions are then verified with tall tower data. It is found that linear regression is poorly suited to MCP applications as the process produces inaccurate estimates of the cube of the wind speed at 50 meters. Meanwhile, Mortimer’s method, which bins data by direction and speed, is found to accurately predict the cube of the wind speed in both sea breeze and non-sea breeze conditions. We also find that log and power law are unstable predictors of wind speeds. While these methods produced accurate estimates of the average 50-meter wind speed at both sites, they predicted an average cube of the wind speed that was between 1.3 and 1.18 times the observed value. Inspection of time-series error reveals increased error in the mid-afternoon of the summer. This suggests that the cold sea breeze may disrupt the vertical temperature profile, create a stable atmosphere and violate the assumptions that allow log law scaling to work.

  10. Accuracy of Multiple Pour Cast from Various Elastomer Impression Methods.

    Science.gov (United States)

    Haralur, Satheesh B; Saad Toman, Majed; Ali Al-Shahrani, Abdullah; Ali Al-Qarni, Abdullah

    2016-01-01

    The accurate duplicate cast obtained from a single impression reduces the profession clinical time, patient inconvenience, and extra material cost. The stainless steel working cast model assembly consisting of two abutments and one pontic area was fabricated. Two sets of six each custom aluminum trays were fabricated, with five mm spacer and two mm spacer. The impression methods evaluated during the study were additional silicone putty reline (two steps), heavy-light body (one step), monophase (one step), and polyether (one step). Type IV gypsum casts were poured at the interval of one hour, 12 hours, 24 hours, and 48 hours. The resultant cast was measured with traveling microscope for the comparative dimensional accuracy. The data obtained were subjected to Analysis of Variance test at significance level impression techniques had the percentage of variation for the height -0.36 to -0.97%, while diameter was increased by 0.40-0.90%. The values for one-step heavy-light body impression dies, additional silicone monophase impressions, and polyether were -0.73 to -1.21%, -1.34%, and -1.46% for the height and 0.50-0.80%, 1.20%, and -1.30% for the width, respectively.

  11. Accuracy of Multiple Pour Cast from Various Elastomer Impression Methods

    Directory of Open Access Journals (Sweden)

    Satheesh B. Haralur

    2016-01-01

    Full Text Available The accurate duplicate cast obtained from a single impression reduces the profession clinical time, patient inconvenience, and extra material cost. The stainless steel working cast model assembly consisting of two abutments and one pontic area was fabricated. Two sets of six each custom aluminum trays were fabricated, with five mm spacer and two mm spacer. The impression methods evaluated during the study were additional silicone putty reline (two steps, heavy-light body (one step, monophase (one step, and polyether (one step. Type IV gypsum casts were poured at the interval of one hour, 12 hours, 24 hours, and 48 hours. The resultant cast was measured with traveling microscope for the comparative dimensional accuracy. The data obtained were subjected to Analysis of Variance test at significance level <0.05. The die obtained from two-step putty reline impression techniques had the percentage of variation for the height −0.36 to −0.97%, while diameter was increased by 0.40–0.90%. The values for one-step heavy-light body impression dies, additional silicone monophase impressions, and polyether were −0.73 to −1.21%, −1.34%, and −1.46% for the height and 0.50–0.80%, 1.20%, and −1.30% for the width, respectively.

  12. Accuracy of a new bedside method for estimation of circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Waever Rasmussen, J; Winther Henneberg, S

    1993-01-01

    To evaluate the accuracy of a modification of the carbon monoxide method of estimating the circulating blood volume.......To evaluate the accuracy of a modification of the carbon monoxide method of estimating the circulating blood volume....

  13. Method for Improving Indoor Positioning Accuracy Using Extended Kalman Filter

    National Research Council Canada - National Science Library

    Lee, Seoung-Hyeon; Lim, Il-Kwan; Lee, Jae-Kwang

    2016-01-01

    .... However, the beacon performance is poor in terms of the indoor positioning accuracy because of noise, motion, and fading, all of which are characteristics of a bluetooth signal and depend on the installation location...

  14. Fundamentals of modern statistical methods substantially improving power and accuracy

    CERN Document Server

    Wilcox, Rand R

    2001-01-01

    Conventional statistical methods have a very serious flaw They routinely miss differences among groups or associations among variables that are detected by more modern techniques - even under very small departures from normality Hundreds of journal articles have described the reasons standard techniques can be unsatisfactory, but simple, intuitive explanations are generally unavailable Improved methods have been derived, but they are far from obvious or intuitive based on the training most researchers receive Situations arise where even highly nonsignificant results become significant when analyzed with more modern methods Without assuming any prior training in statistics, Part I of this book describes basic statistical principles from a point of view that makes their shortcomings intuitive and easy to understand The emphasis is on verbal and graphical descriptions of concepts Part II describes modern methods that address the problems covered in Part I Using data from actual studies, many examples are include...

  15. High Accuracy Near-infrared Imaging Polarimetry with NICMOS

    CERN Document Server

    Batcheldor, D; Hines, D C; Schmidt, G D; Axon, D J; Robinson, A; Sparks, W; Tadhunter, C

    2008-01-01

    The findings of a nine orbit calibration plan carried out during HST Cycle 15, to fully determine the NICMOS camera 2 (2.0 micron) polarization calibration to high accuracy, are reported. Recently Ueta et al. and Batcheldor et al. have suggested that NICMOS possesses a residual instrumental polarization at a level of 1.2-1.5%. This would completely inhibit the data reduction in a number of GO programs, and hamper the ability of the instrument to perform high accuracy polarimetry. We obtained polarimetric calibration observations of three polarimetric standards at three spacecraft roll angles separated by ~60deg. Combined with archival data, these observations were used to characterize the residual instrumental polarization in order for NICMOS to reach its full potential of accurate imaging polarimetry at p~1%. Using these data, we place an 0.6% upper limit on the instrumental polarization and calculate values of the parallel transmission coefficients that reproduce the ground-based results for the polarimetri...

  16. High-accuracy mass spectrometry for fundamental studies.

    Science.gov (United States)

    Kluge, H-Jürgen

    2010-01-01

    Mass spectrometry for fundamental studies in metrology and atomic, nuclear and particle physics requires extreme sensitivity and efficiency as well as ultimate resolving power and accuracy. An overview will be given on the global status of high-accuracy mass spectrometry for fundamental physics and metrology. Three quite different examples of modern mass spectrometric experiments in physics are presented: (i) the retardation spectrometer KATRIN at the Forschungszentrum Karlsruhe, employing electrostatic filtering in combination with magnetic-adiabatic collimation-the biggest mass spectrometer for determining the smallest mass, i.e. the mass of the electron anti-neutrino, (ii) the Experimental Cooler-Storage Ring at GSI-a mass spectrometer of medium size, relative to other accelerators, for determining medium-heavy masses and (iii) the Penning trap facility, SHIPTRAP, at GSI-the smallest mass spectrometer for determining the heaviest masses, those of super-heavy elements. Finally, a short view into the future will address the GSI project HITRAP at GSI for fundamental studies with highly-charged ions.

  17. Effects of CT image segmentation methods on the accuracy of long bone 3D reconstructions.

    Science.gov (United States)

    Rathnayaka, Kanchana; Sahama, Tony; Schuetz, Michael A; Schmutz, Beat

    2011-03-01

    An accurate and accessible image segmentation method is in high demand for generating 3D bone models from CT scan data, as such models are required in many areas of medical research. Even though numerous sophisticated segmentation methods have been published over the years, most of them are not readily available to the general research community. Therefore, this study aimed to quantify the accuracy of three popular image segmentation methods, two implementations of intensity thresholding and Canny edge detection, for generating 3D models of long bones. In order to reduce user dependent errors associated with visually selecting a threshold value, we present a new approach of selecting an appropriate threshold value based on the Canny filter. A mechanical contact scanner in conjunction with a microCT scanner was utilised to generate the reference models for validating the 3D bone models generated from CT data of five intact ovine hind limbs. When the overall accuracy of the bone model is considered, the three investigated segmentation methods generated comparable results with mean errors in the range of 0.18-0.24 mm. However, for the bone diaphysis, Canny edge detection and Canny filter based thresholding generated 3D models with a significantly higher accuracy compared to those generated through visually selected thresholds. This study demonstrates that 3D models with sub-voxel accuracy can be generated utilising relatively simple segmentation methods that are available to the general research community.

  18. A SVD-based method to assess the uniqueness and accuracy of SPECT geometrical calibration.

    Science.gov (United States)

    Ma, Tianyu; Yao, Rutao; Shao, Yiping; Zhou, Rong

    2009-12-01

    Geometrical calibration is critical to obtaining high resolution and artifact-free reconstructed image for SPECT and CT systems. Most published calibration methods use analytical approach to determine the uniqueness condition for a specific calibration problem, and the calibration accuracy is often evaluated through empirical studies. In this work, we present a general method to assess the characteristics of both the uniqueness and the quantitative accuracy of the calibration. The method uses a singular value decomposition (SVD) based approach to analyze the Jacobian matrix from a least-square cost function for the calibration. With this method, the uniqueness of the calibration can be identified by assessing the nonsingularity of the Jacobian matrix, and the estimation accuracy of the calibration parameters can be quantified by analyzing the SVD components. A direct application of this method is that the efficacy of a calibration configuration can be quantitatively evaluated by choosing a figure-of-merit, e.g., the minimum required number of projection samplings to achieve desired calibration accuracy. The proposed method was validated with a slit-slat SPECT system through numerical simulation studies and experimental measurements with point sources and an ultra-micro hot-rod phantom. The predicted calibration accuracy from the numerical studies was confirmed by the experimental point source calibrations at approximately 0.1 mm for both the center of rotation (COR) estimation of a rotation stage and the slit aperture position (SAP) estimation of a slit-slat collimator by an optimized system calibration protocol. The reconstructed images of a hot rod phantom showed satisfactory spatial resolution with a proper calibration and showed visible resolution degradation with artificially introduced 0.3 mm COR estimation error. The proposed method can be applied to other SPECT and CT imaging systems to analyze calibration method assessment and calibration protocol

  19. THE ACCURACY AND BIAS EVALUATION OF THE USA UNEMPLOYMENT RATE FORECASTS. METHODS TO IMPROVE THE FORECASTS ACCURACY

    Directory of Open Access Journals (Sweden)

    MIHAELA BRATU (SIMIONESCU

    2012-12-01

    Full Text Available In this study some alternative forecasts for the unemployment rate of USA made by four institutions (International Monetary Fund (IMF, Organization for Economic Co-operation and Development (OECD, Congressional Budget Office (CBO and Blue Chips (BC are evaluated regarding the accuracy and the biasness. The most accurate predictions on the forecasting horizon 201-2011 were provided by IMF, followed by OECD, CBO and BC.. These results were gotten using U1 Theil’s statistic and a new method that has not been used before in literature in this context. The multi-criteria ranking was applied to make a hierarchy of the institutions regarding the accuracy and five important accuracy measures were taken into account at the same time: mean errors, mean squared error, root mean squared error, U1 and U2 statistics of Theil. The IMF, OECD and CBO predictions are unbiased. The combined forecasts of institutions’ predictions are a suitable strategy to improve the forecasts accuracy of IMF and OECD forecasts when all combination schemes are used, but INV one is the best. The filtered and smoothed original predictions based on Hodrick-Prescott filter, respectively Holt-Winters technique are a good strategy of improving only the BC expectations. The proposed strategies to improve the accuracy do not solve the problem of biasness. The assessment and improvement of forecasts accuracy have an important contribution in growing the quality of decisional process.

  20. Researching the technology of high-accuracy camshaft measurement

    Science.gov (United States)

    Chen, Wei; Chen, Yong-Le; Wang, Hong; Liao, Hai-Yang

    1996-10-01

    This paper states the cam's data processing algorithm in detail in high accurate camshaft measurement system. It contains: 1) using minimum error of curve symmetry to seek the center position of the key slot; 2) Calculating the minimum error by cam's curve in theory to search top area; 3) According to cam's tolerance E(i) function and minimum angle error at cam top, seeking the best position of cam top and getting the best angle value and error curve. The algorithm is suitable for measuring all kinds of symmetry or asymmetry cam, and plain push-rod or spherical push-rod cam, for example, bus camshaft, car camshaft, motor camshaft, etc. Using the algorithm, high accuracy measurement can be achieved.

  1. Read-only high accuracy volume holographic optical correlator

    Science.gov (United States)

    Zhao, Tian; Li, Jingming; Cao, Liangcai; He, Qingsheng; Jin, Guofan

    2011-10-01

    A read-only volume holographic correlator (VHC) is proposed. After the recording of all of the correlation database pages by angular multiplexing, a stand-alone read-only high accuracy VHC will be separated from the VHC recording facilities which include the high-power laser and the angular multiplexing system. The stand-alone VHC has its own low power readout laser and very compact and simple structure. Since there are two lasers that are employed for recording and readout, respectively, the optical alignment tolerance of the laser illumination on the SLM is very sensitive. The twodimensional angular tolerance is analyzed based on the theoretical model of the volume holographic correlator. The experimental demonstration of the proposed read-only VHC is introduced and discussed.

  2. Evaluating clinical accuracy of continuous glucose monitoring devices: other methods.

    Science.gov (United States)

    Wentholt, Iris M E; Hart, August A; Hoekstra, Joost B L; DeVries, J Hans

    2008-08-01

    With more and more continuous glucose monitoring devices entering the market, the importance of adequate accuracy assessment grows. This review discusses pros and cons of Regression Analysis and Correlation Coefficient, Relative Difference measures, Bland Altman plot, ISO criteria, combined curve fitting, and epidemiological analyses, the latter including sensitivity, specificity and positive predictive value for hypoglycaemia. Finally, recommendations for much needed head-to-head studies are given. This paper is a revised and adapted version of How to assess and compare the accuracy of continuous glucose monitors?, Diabetes Technology and Therapeutics 2007, in press, published with permission of the editor.

  3. Development of high accuracy and resolution geoid and gravity maps

    Science.gov (United States)

    Gaposchkin, E. M.

    1986-01-01

    Precision satellite to satellite tracking can be used to obtain high precision and resolution maps of the geoid. A method is demonstrated to use data in a limited region to map the geopotential at the satellite altitude. An inverse method is used to downward continue the potential to the Earth surface. The method is designed for both satellites in the same low orbit.

  4. High-speed, high-accuracy large range 3D measurement

    Science.gov (United States)

    An, Yatong; Zhang, Song

    2017-05-01

    This paper presents such a high-speed, high-accuracy structured light technique that could achieve large range 3D shape measurement. The enabling method is our recently proposed system calibration that splits the calibration process into two stages. Specifically, we calibrate the intrinsic parameters at a near position with a regular size yet precisely fabricated calibration target, and then calibrate the extrinsic parameters with the assistance of an additional large range yet low accuracy low cost 3D scanner (i.e., Kinect). We developed a system that achieved 500 Hz with a resolution 2304 × 1400. The field of view (FOV) of our structured light system is 0.9 m(W) × 1.4 m(H) × 0.8 m(D). Our experimental data demonstrated that such a large range structured light system can achieve an mean error of 0.13 mm with a standard deviation of 1.18 mm by measuring a 304.8 mm diameter sphere. We further experimentally demonstrated that proposed method can simultaneously measure multiple objects or large dynamically changing objects.

  5. Accuracy of genomic selection using different methods to define haplotypes

    NARCIS (Netherlands)

    Calus, M.P.L.; Meuwissen, T.H.E.; Roos, de S.; Veerkamp, R.F.

    2008-01-01

    Genomic selection uses total breeding values for juvenile animals, predicted from a large number of estimated marker haplotype effects across the whole genome. In this study the accuracy of predicting breeding values is compared for four different models including a large number of markers, at diffe

  6. Assessment of calibration methods on impedance pneumography accuracy.

    Science.gov (United States)

    Młyńczak, Marcel; Niewiadomski, Wiktor; Żyliński, Marek; Cybulski, Gerard

    2016-12-01

    The aim was to assess accuracy of tidal volumes (TV) calculated by impedance pneumography (IP), reproducibility of calibration coefficients (CC) between IP and pneumotachometry (PNT), and their relationship with body posture, breathing rate and depth. Fourteen students performed three sessions of 18 series: normal and deep breathing at 6, 10, 15 breaths/min rates, while supine, sitting and standing; 18 CC were calculated for every session. Session 2 was performed 2 months after session 1, session 3 1-3 days after session 2. TV were calculated using full or limited set of CC from current session, in case of sessions 2 and 3 also using CC from session 1 and 2, respectively. When using full set of CC from current session, IP underestimated TV by -3.2%. Using CC from session 2 for session 3 measurements caused decrease of relative difference: -3.9%, from session 1 for session 2: -5.3%; for limited set of CC: -5.0%. The body posture had significant effect on CC. The highest accuracy was obtained when all factors influencing CC were considered. The application of CC related only to body posture may result in shortening of calibration and moderate accuracy loss. Using CC from previous session compromises accuracy moderately.

  7. Accuracy assessment of the UT1 prediction method based on 100-year series analysis

    CERN Document Server

    Malkin, Z; Tolstikov, A

    2013-01-01

    A new method has been developed at the Siberian Research Institute of Metrology (SNIIM) for highly accurate prediction of UT1 and Pole coordinates. The method is based on construction of a general polyharmonic model of the variations of the Earth rotation parameters using all the data available for the last 80-100 years, and modified autoregression technique. In this presentation, a detailed comparison was made of real-time UT1 predictions computed making use of this method in 2006-2010 with simultaneous predictions computed at the International Earth Rotation and Reference Systems Service (IERS). Obtained results have shown that proposed method provides better accuracy at different prediction lengths.

  8. Accuracy of methods to measure femoral head penetration within metal-backed acetabular components.

    Science.gov (United States)

    Callary, Stuart A; Solomon, Lucian B; Holubowycz, Oksana T; Campbell, David G; Howie, Donald W

    2016-06-30

    A number of different software programs are used to investigate the in vivo wear of polyethylene bearings in total hip arthroplasty. With wear rates below 0.1 mm/year now commonly being reported for highly cross-linked polyethylene (XLPE) components, it is important to identify the accuracy of the methods used to measure such small movements. The aims of this study were to compare the accuracy of current software programs used to measure two-dimensional (2D) femoral head penetration (FHP) and to determine whether the accuracy is influenced by larger femoral heads or by different methods of representing the acetabular component within radiostereometric analysis (RSA). A hip phantom was used to compare known movements of the femoral head within a metal-backed acetabular component to FHP measured radiographically using RSA, Hip Analysis Suite (HAS), PolyWare, Ein Bild Roentgen Analyse (EBRA), and Roentgen Monographic Analysis Tool (ROMAN). RSA was significantly more accurate than the HAS, PolyWare, and ROMAN methods when measuring 2D FHP with a 28 mm femoral head. Femoral head size influenced the accuracy of HAS and ROMAN 2D FHP measurements, EBRA proximal measurements, and RSA measurements in the proximal and anterior direction. The use of different acetabular reference segments did not influence accuracy of RSA measurements. The superior accuracy and reduced variability of RSA wear measurements allow much smaller cohorts to be used in RSA clinical wear studies than those utilizing other software programs. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.

  9. The effect of atmospheric and topographic correction methods on land cover classification accuracy

    Science.gov (United States)

    Vanonckelen, Steven; Lhermitte, Stefaan; Van Rompaey, Anton

    2013-10-01

    of different land cover types in the landscape. Finally, coupled correction methods showed most efficient on weakly illuminated slopes. After correction, accuracies in the low illumination zone (cos β ≤ 0.65) were improved more than in the moderate and high illumination zones. Considering all results, best overall classification results were achieved after combination of the transmittance function correction with pixel-based Minnaert or pixel-based C-topographic correction. Furthermore, results of this bi-temporal study indicated that the topographic component had a higher influence on classification accuracy than the atmospheric component and that it is worthwhile to invest in both atmospheric and topographic corrections in a multi-temporal study.

  10. A new method for measuring the rotational accuracy of rolling element bearings

    Science.gov (United States)

    Chen, Ye; Zhao, Xiangsong; Gao, Weiguo; Hu, Gaofeng; Zhang, Shizhen; Zhang, Dawei

    2016-12-01

    The rotational accuracy of a machine tool spindle has critical influence upon the geometric shape and surface roughness of finished workpiece. The rotational performance of the rolling element bearings is a main factor which affects the spindle accuracy, especially in the ultra-precision machining. In this paper, a new method is developed to measure the rotational accuracy of rolling element bearings of machine tool spindles. Variable and measurable axial preload is applied to seat the rolling elements in the bearing races, which is used to simulate the operating conditions. A high-precision (radial error is less than 300 nm) and high-stiffness (radial stiffness is 600 N/μm) hydrostatic reference spindle is adopted to rotate the inner race of the test bearing. To prevent the outer race from rotating, a 2-degrees of freedom flexure hinge mechanism (2-DOF FHM) is designed. Correction factors by using stiffness analysis are adopted to eliminate the influences of 2-DOF FHM in the radial direction. Two capacitive displacement sensors with nano-resolution (the highest resolution is 9 nm) are used to measure the radial error motion of the rolling element bearing, without separating the profile error as the traditional rotational accuracy metrology of the spindle. Finally, experimental measurements are performed at different spindle speeds (100-4000 rpm) and axial preloads (75-780 N). Synchronous and asynchronous error motion values are evaluated to demonstrate the feasibility and repeatability of the developed method and instrument.

  11. Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy

    OpenAIRE

    Zhao, Yi-jiao; Xiong, Yu-xue; Wang, Yong

    2017-01-01

    In this study, the practical accuracy (PA) of optical facial scanners for facial deformity patients in oral clinic was evaluated. Ten patients with a variety of facial deformities from oral clinical were included in the study. For each patient, a three-dimensional (3D) face model was acquired, via a high-accuracy industrial “line-laser” scanner (Faro), as the reference model and two test models were obtained, via a “stereophotography” (3dMD) and a “structured light” facial scanner (FaceScan) ...

  12. Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy.

    Science.gov (United States)

    Zhao, Yi-Jiao; Xiong, Yu-Xue; Wang, Yong

    2017-01-01

    In this study, the practical accuracy (PA) of optical facial scanners for facial deformity patients in oral clinic was evaluated. Ten patients with a variety of facial deformities from oral clinical were included in the study. For each patient, a three-dimensional (3D) face model was acquired, via a high-accuracy industrial "line-laser" scanner (Faro), as the reference model and two test models were obtained, via a "stereophotography" (3dMD) and a "structured light" facial scanner (FaceScan) separately. Registration based on the iterative closest point (ICP) algorithm was executed to overlap the test models to reference models, and "3D error" as a new measurement indicator calculated by reverse engineering software (Geomagic Studio) was used to evaluate the 3D global and partial (upper, middle, and lower parts of face) PA of each facial scanner. The respective 3D accuracy of stereophotography and structured light facial scanners obtained for facial deformities was 0.58±0.11 mm and 0.57±0.07 mm. The 3D accuracy of different facial partitions was inconsistent; the middle face had the best performance. Although the PA of two facial scanners was lower than their nominal accuracy (NA), they all met the requirement for oral clinic use.

  13. Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy

    Science.gov (United States)

    Zhao, Yi-jiao; Xiong, Yu-xue; Wang, Yong

    2017-01-01

    In this study, the practical accuracy (PA) of optical facial scanners for facial deformity patients in oral clinic was evaluated. Ten patients with a variety of facial deformities from oral clinical were included in the study. For each patient, a three-dimensional (3D) face model was acquired, via a high-accuracy industrial “line-laser” scanner (Faro), as the reference model and two test models were obtained, via a “stereophotography” (3dMD) and a “structured light” facial scanner (FaceScan) separately. Registration based on the iterative closest point (ICP) algorithm was executed to overlap the test models to reference models, and “3D error” as a new measurement indicator calculated by reverse engineering software (Geomagic Studio) was used to evaluate the 3D global and partial (upper, middle, and lower parts of face) PA of each facial scanner. The respective 3D accuracy of stereophotography and structured light facial scanners obtained for facial deformities was 0.58±0.11 mm and 0.57±0.07 mm. The 3D accuracy of different facial partitions was inconsistent; the middle face had the best performance. Although the PA of two facial scanners was lower than their nominal accuracy (NA), they all met the requirement for oral clinic use. PMID:28056044

  14. High-Order Kinetic Relaxation Schemes as High-Accuracy Poisson Solvers

    CERN Document Server

    Mendoza, M; Herrmann, H J

    2015-01-01

    We present a new approach to find accurate solutions to the Poisson equation, as obtained from the steady-state limit of a diffusion equation with strong source terms. For this purpose, we start from Boltzmann's kinetic theory and investigate the influence of higher order terms on the resulting macroscopic equations. By performing an appropriate expansion of the equilibrium distribution, we provide a method to remove the unnecessary terms up to a desired order and show that it is possible to find, with high level of accuracy, the steady-state solution of the diffusion equation for sizeable Knudsen numbers. In order to test our kinetic approach, we discretise the Boltzmann equation and solve the Poisson equation, spending up to six order of magnitude less computational time for a given precision than standard lattice Boltzmann methods.

  15. Accuracy assessment of the ERP prediction method based on analysis of 100-year ERP series

    Science.gov (United States)

    Malkin, Z.; Tissen, V. M.

    2012-12-01

    A new method has been developed at the Siberian Research Institute of Metrology (SNIIM) for highly accurate prediction of UT1 and Pole motion (PM). In this study, a detailed comparison was made of real-time UT1 predictions made in 2006-2011 and PMpredictions made in 2009-2011making use of the SNIIM method with simultaneous predictions computed at the International Earth Rotation and Reference Systems Service (IERS), USNO. Obtained results have shown that proposed method provides better accuracy at different prediction lengths.

  16. Fragmentation of DNA affects the accuracy of the DNA quantitation by the commonly used methods

    Directory of Open Access Journals (Sweden)

    Sedlackova Tatiana

    2013-02-01

    Full Text Available Abstract Background Specific applications and modern technologies, like non-invasive prenatal testing, non-invasive cancer diagnostic and next generation sequencing, are currently in the focus of researchers worldwide. These have common characteristics in use of highly fragmented DNA molecules for analysis. Hence, for the performance of molecular methods, DNA concentration is a crucial parameter; we compared the influence of different levels of DNA fragmentation on the accuracy of DNA concentration measurements. Results In our comparison, the performance of the currently most commonly used methods for DNA concentration measurement (spectrophotometric, fluorometric and qPCR based were tested on artificially fragmented DNA samples. In our comparison, unfragmented and three specifically fragmented DNA samples were used. According to our results, the level of fragmentation did not influence the accuracy of spectrophotometric measurements of DNA concentration, while other methods, fluorometric as well as qPCR-based, were significantly influenced and a decrease in measured concentration was observed with more intensive DNA fragmentation. Conclusions Our study has confirmed that the level of fragmentation of DNA has significant impact on accuracy of DNA concentration measurement with two of three mostly used methods (PicoGreen and qPCR. Only spectrophotometric measurement was not influenced by the level of fragmentation, but sensitivity of this method was lowest among the three tested. Therefore if it is possible the DNA quantification should be performed with use of equally fragmented control DNA.

  17. Monitoring techniques for high accuracy interference fit assembly processes

    Science.gov (United States)

    Liuti, A.; Vedugo, F. Rodriguez; Paone, N.; Ungaro, C.

    2016-06-01

    In the automotive industry, there are many assembly processes that require a high geometric accuracy, in the micrometer range; generally open-loop controllers cannot meet these requirements. This results in an increased defect rate and high production costs. This paper presents an experimental study of interference fit process, aimed to evaluate the aspects which have the most impact on the uncertainty in the final positioning. The press-fitting process considered, consists in a press machine operating with a piezoelectric actuator to press a plug into a sleeve. Plug and sleeve are designed and machined to obtain a known interference fit. Differential displacement and velocity measurements of the plug with respect to the sleeve are measured by a fiber optic differential laser Doppler vibrometer. Different driving signals of the piezo actuator allow to have an insight into the differences between a linear and a pulsating press action. The paper highlights how the press-fit assembly process is characterized by two main phases: the first is an elastic deformation of the plug and sleeve, which produces a reversible displacement, the second is a sliding of the plug with respect to the sleeve, which results in an irreversible displacement and finally realizes the assembly. The simultaneous measurements of the displacement and the force have permitted to define characteristic features in the signal useful to identify the start of the irreversible movement. These indicators could be used to develop a control logic in a press assembly process.

  18. A high-accuracy DCO with hybrid architecture

    Science.gov (United States)

    Sun, Yapeng; Zhao, Huidong; Qiao, Shushan; Hei, Yong; Zhang, Fuhai

    2017-07-01

    In this paper, a novel hybrid digital-controlled oscillator (DCO) is proposed, which is used to improve the accuracy of the all-digital clock generator without reference source. The DCO with hybrid architecture consists of two parts: DCO_high and DCO_low. The DCO_high decides the coarse output frequency of DCO, and adopts the cascade structure to decrease the area. The DCO_low adopts the chain structure with three-state buffer, and decides the fine output frequency of DCO. Compared with traditional cascade DCO, the proposed hybrid DCO features higher precision with less inherent delay. Therefore the clock generator can tolerate process, voltage and temperature (PVT) variation and meet the needs of different conditions. The DCO is designed in SMIC 180 nm CMOS process with 0.021 mm2 chip area. The output frequency is adjusted from 15-120 MHz. The frequency error is less than 0.83% at 25 MHz with 1.6-1.8 V supply voltage and 0-80 °C temperature variations in TT, FF, SS corners. Project supported by the National Natural Science Foundation of China (Nos. 61306025, 61474135).

  19. AN EVALUATION OF USA UNEMPLOYMENT RATE FORECASTS IN TERMS OF ACCURACY AND BIAS. EMPIRICAL METHODS TO IMPROVE THE FORECASTS ACCURACY

    Directory of Open Access Journals (Sweden)

    BRATU (SIMIONESCU MIHAELA

    2013-02-01

    Full Text Available The most accurate forecasts for USA unemployment rate on the horizon 2001-2012, according to U1 Theil’s coefficient and to multi-criteria ranking methods, were provided by International Monetary Fund (IMF, being followed by other institutions as: Organization for Economic Co-operation and Development (OECD, Congressional Budget Office (CBO and Blue Chips (BC. The multi-criteria ranking methods were applied to solve the divergence in assessing the accuracy, differences observed by computing five chosen measures of accuracy: U1 and U2 statistics of Theil, mean error, mean squared error, root mean squared error. Some strategies of improving the accuracy of the predictions provided by the four institutions, which are biased in all cases, excepting BC, were proposed. However, these methods did not generate unbiased forecasts. The predictions made by IMF and OECD for 2001-2012 can be improved by constructing combined forecasts, the INV approach and the scheme proposed by author providing the most accurate expections. The BC forecasts can be improved by smoothing the predictions using Holt-Winters method and Hodrick - Prescott filter.

  20. 基于时延的高精度泄漏点超声定向检测方法%High accuracy method of ultrasonic gas leak direction detection based on time delay estimation

    Institute of Scientific and Technical Information of China (English)

    廖平平; 蔡茂林

    2013-01-01

    In order to solve the low accuracy problem in current gas leak detection, a new ultrasonic leak detection method based on time delay estimation (TDE) was proposed. Three ultrasonic sensors arranged in an equilateral triangle and received the ultrasound generated by a gas leak and the leak direction can be determined according to time delays between the outputs of every two sensors. A TDE algorithm based on cubic spline interpolation was adopted to overcome the accuracy limit caused by sampling interval. For each kernel window length, delay estimates of 100 sets of experimental data were obtained and their mean squared errors (MSE) were calculated. Comparison between MSE of experimental data and Cramer-Rao lower bound showed that their changing tendency was accordant. Influences of MSE, the space between sensors and the distance between leak and sensor on direction accuracy were analyzed. Results show that the direction error increases with MSE, decreases with the space between sensors, and increases with distance between leak and sensor. The direction detection accuracy is improved by 7 ~10 times compared with detection method with single ultrasonic sensor.%针对当前气体泄漏点检测定向精度低的情况,提出一种基于时延的高精度超声检测方法.该方法利用3个呈等边三角形分布的超声传感器接收由泄漏点产生的超声波,根据3路信号的相对时延值确定泄漏点的方向.为克服采样间隔对时延估计精度的限制,采用基于三次样条插值的时延估计算法估计信号时延值,并对不同核窗长度下的各100组实验数据的时延值进行误差统计,得到其均方差并与其Cramér-Rao下界比较,发现二者的变化趋势具有良好的一致性.在此基础上研究了时延值均方差,超声传感器间距和泄漏点距离对定向精度的影响.结果表明:定向误差随时延值均方差增大而增大,随超声传感器间距增大而减小,随泄漏点距离增大而增大

  1. Sensitivity analysis for high accuracy proximity effect correction

    Science.gov (United States)

    Thrun, Xaver; Browning, Clyde; Choi, Kang-Hoon; Figueiro, Thiago; Hohle, Christoph; Saib, Mohamed; Schiavone, Patrick; Bartha, Johann W.

    2015-10-01

    A sensitivity analysis (SA) algorithm was developed and tested to comprehend the influences of different test pattern sets on the calibration of a point spread function (PSF) model with complementary approaches. Variance-based SA is the method of choice. It allows attributing the variance of the output of a model to the sum of variance of each input of the model and their correlated factors.1 The objective of this development is increasing the accuracy of the resolved PSF model in the complementary technique through the optimization of test pattern sets. Inscale® from Aselta Nanographics is used to prepare the various pattern sets and to check the consequences of development. Fraunhofer IPMS-CNT exposed the prepared data and observed those to visualize the link of sensitivities between the PSF parameters and the test pattern. First, the SA can assess the influence of test pattern sets for the determination of PSF parameters, such as which PSF parameter is affected on the employments of certain pattern. Secondly, throughout the evaluation, the SA enhances the precision of PSF through the optimization of test patterns. Finally, the developed algorithm is able to appraise what ranges of proximity effect correction is crucial on which portion of a real application pattern in the electron beam exposure.

  2. Determination of UAV position using high accuracy navigation platform

    Directory of Open Access Journals (Sweden)

    Ireneusz Kubicki

    2016-07-01

    Full Text Available The choice of navigation system for mini UAV is very important because of its application and exploitation, particularly when the installed on it a synthetic aperture radar requires highly precise information about an object’s position. The presented exemplary solution of such a system draws attention to the possible problems associated with the use of appropriate technology, sensors, and devices or with a complete navigation system. The position and spatial orientation errors of the measurement platform influence on the obtained SAR imaging. Both, turbulences and maneuvers performed during flight cause the changes in the position of the airborne object resulting in deterioration or lack of images from SAR. Consequently, it is necessary to perform operations for reducing or eliminating the impact of the sensors’ errors on the UAV position accuracy. You need to look for compromise solutions between newer better technologies and in the field of software. Keywords: navigation systems, unmanned aerial vehicles, sensors integration

  3. Link Prediction Methods and Their Accuracy for Different Social Networks and Network Metrics

    Directory of Open Access Journals (Sweden)

    Fei Gao

    2015-01-01

    Full Text Available Currently, we are experiencing a rapid growth of the number of social-based online systems. The availability of the vast amounts of data gathered in those systems brings new challenges that we face when trying to analyse it. One of the intensively researched topics is the prediction of social connections between users. Although a lot of effort has been made to develop new prediction approaches, the existing methods are not comprehensively analysed. In this paper we investigate the correlation between network metrics and accuracy of different prediction methods. We selected six time-stamped real-world social networks and ten most widely used link prediction methods. The results of the experiments show that the performance of some methods has a strong correlation with certain network metrics. We managed to distinguish “prediction friendly” networks, for which most of the prediction methods give good performance, as well as “prediction unfriendly” networks, for which most of the methods result in high prediction error. Correlation analysis between network metrics and prediction accuracy of prediction methods may form the basis of a metalearning system where based on network characteristics it will be able to recommend the right prediction method for a given network.

  4. Forecasting method in multilateration accuracy based on laser tracker measurement

    Science.gov (United States)

    Aguado, Sergio; Santolaria, Jorge; Samper, David; José Aguilar, Juan

    2017-02-01

    Multilateration based on a laser tracker (LT) requires the measurement of a set of points from three or more positions. Although the LTs’ angular information is not used, multilateration produces a volume of measurement uncertainty. This paper presents two new coefficients from which to determine whether the measurement of a set of points, before performing the necessary measurements, will improve or worsen the accuracy of the multilateration results, avoiding unnecessary measurement, and reducing the time and economic cost required. The first specific coefficient measurement coefficient (MCLT) is unique for each laser tracker. It determines the relationship between the radial and angular laser tracker measurement noise. Similarly, the second coefficient is related with specific conditions of measurement β. It is related with the spatial angle between the laser tracker positions α and its effect on error reduction. Both parameters MCLT and β are linked in error reduction limits. Beside these, a new methodology to determine the multilateration reduction limit according to the multilateration technique of an ideal laser tracker distribution and a random one are presented. It provides general rules and advice from synthetic tests that are validated through a real test carried out in a coordinate measurement machine.

  5. Subpixel Accuracy Analysis of Phase Correlation Shift Measurement Methods Applied to Satellite Imagery

    Directory of Open Access Journals (Sweden)

    S.M. Badwai

    2013-01-01

    Full Text Available the key point of super resolution process is the accurate measuring of sub-pixel shift. Any tiny error in measuring such shift leads to an incorrect image focusing. In this paper, methodology of measuring sub-pixel shift using Phase correlation (PC are evaluated using different window functions, then modified version of (PC method using high pass filter (HPF is introduced . Comprehensive analysis and assessment of (PC methods shows that different natural features yield different shift measurements. It is concluded that there is no universal window function for measuring shift; it mainly depends on the features in the satellite images. Even the question of which window is optimal of particular feature is generally remains open. This paper presents the design of a method for obtaining high accuracy sub pixel shift phase correlation using (HPF.The proposed method makes the change in the different locations that lack of edges easy.

  6. Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients

    Directory of Open Access Journals (Sweden)

    Asadian S

    2016-09-01

    Full Text Available Simin Asadian,1 Alireza Khatony,1 Gholamreza Moradi,2 Alireza Abdi,1 Mansour Rezaei,3 1Nursing and Midwifery School, Kermanshah University of Medical Sciences, 2Department of Anesthesiology, 3Biostatistics & Epidemiology Department, Kermanshah University of Medical Sciences, Kermanshah, Iran Introduction: An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. Methods: In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients’ body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. Results: There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (P<0.001. Kappa coefficients showed good agreement between the temperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%. Paired t-test demonstrated an acceptable precision with forehead (P=0.132, left (P=0.18 and right (P=0.318 tympanic membranes, oral (P=1.00, and axillary (P=1.00 methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. Conclusion: The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left for

  7. Stability, accuracy and numerical diffusion analysis of nodal expansion method for steady convection diffusion equation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xiafeng, E-mail: zhou-xf11@mails.tsinghua.edu.cn; Guo, Jiong, E-mail: guojiong12@tsinghua.edu.cn; Li, Fu, E-mail: lifu@tsinghua.edu.cn

    2015-12-15

    Highlights: • NEMs are innovatively applied to solve convection diffusion equation. • Stability, accuracy and numerical diffusion for NEM are analyzed for the first time. • Stability and numerical diffusion depend on the NEM expansion order and its parity. • NEMs have higher accuracy than both second order upwind and QUICK scheme. • NEMs with different expansion orders are integrated into a unified discrete form. - Abstract: The traditional finite difference method or finite volume method (FDM or FVM) is used for HTGR thermal-hydraulic calculation at present. However, both FDM and FVM require the fine mesh sizes to achieve the desired precision and thus result in a limited efficiency. Therefore, a more efficient and accurate numerical method needs to be developed. Nodal expansion method (NEM) can achieve high accuracy even on the coarse meshes in the reactor physics analysis so that the number of spatial meshes and computational cost can be largely decreased. Because of higher efficiency and accuracy, NEM can be innovatively applied to thermal-hydraulic calculation. In the paper, NEMs with different orders of basis functions are successfully developed and applied to multi-dimensional steady convection diffusion equation. Numerical results show that NEMs with three or higher order basis functions can track the reference solutions very well and are superior to second order upwind scheme and QUICK scheme. However, the false diffusion and unphysical oscillation behavior are discovered for NEMs. To explain the reasons for the above-mentioned behaviors, the stability, accuracy and numerical diffusion properties of NEM are analyzed by the Fourier analysis, and by comparing with exact solutions of difference and differential equation. The theoretical analysis results show that the accuracy of NEM increases with the expansion order. However, the stability and numerical diffusion properties depend not only on the order of basis functions but also on the parity of

  8. ErrorCheck: A New Method for Controlling the Accuracy of Pose Estimates

    DEFF Research Database (Denmark)

    Holm, Preben Hagh Strunge; Petersen, Henrik Gordon

    2011-01-01

    In this paper, we present ErrorCheck, which is a new method for controlling the accuracy of a computer vision based pose refinement method. ErrorCheck consists of a way for validating robustness of a pose refinement method towards false correspondences and a way of controlling the accuracy...... of a validated pose refinement method. ErrorCheck uses a theoretical estimate of the pose error covariance both for validating robustness and controlling the accuracy.We illustrate the first usage of ErrorCheck by applying it to state-of-the-art methods for pose refinement and some variations of these methods...

  9. On the accuracy of low-order projection methods

    OpenAIRE

    Paul Pichler

    2007-01-01

    We use low-order projection methods to compute numerical solutions of the basic neoclassical stochastic growth model. We assess the quality of the obtained solutions, and compare them to numerical approximations derived with first and second-order perturbation techniques. We show that projection methods perform surprisingly poor when the degree of approximation is very low, and we provide some intuition behind this finding.

  10. A high-accuracy surgical augmented reality system using enhanced integral videography image overlay.

    Science.gov (United States)

    Zhang, Xinran; Chen, Guowen; Liao, Hongen

    2015-01-01

    Image guided surgery has been used in clinic to improve the surgery safety and accuracy. Augmented reality (AR) technique, which can provide intuitive image guidance, has been greatly evolved these years. As one promising approach of surgical AR systems, integral videography (IV) autostereoscopic image overlay has achieved accurate fusion of full parallax guidance into surgical scene. This paper describes an image enhanced high-accuracy IV overlay system. A flexible optical image enhancement system (IES) is designed to increase the resolution and quality of IV image. Furthermore, we introduce a novel IV rendering algorithm to promote the spatial accuracy with the consideration of distortion introduced by micro lens array. Preliminary experiments validated that the image accuracy and resolution are improved with the proposed methods. The resolution of the IV image could be promoted to 1 mm for a micro lens array with pitch of 2.32 mm and IES magnification value of 0.5. The relative deviation of accuracy in depth and lateral directions are -4.68 ± 0.83% and -9.01 ± 0.42%.

  11. Study of accuracy of precipitation measurements using simulation method

    Science.gov (United States)

    Nagy, Zoltán; Lajos, Tamás; Morvai, Krisztián

    2013-04-01

    of wind shield improve the accuracy of precipitation measurements? · Try to find the source of the error that can be detected at tipping bucket raingauge in winter time because of use of heating power? On our poster we would like to present the answers to the questions listed above.

  12. Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine.

    Science.gov (United States)

    Wilson, Derek C; Niosi, Christina A; Zhu, Qingan A; Oxland, Thomas R; Wilson, David R

    2006-01-01

    We assessed the repeatability and accuracy of a relatively new, resistance-based sensor (Tekscan 6900) for measuring lumbar spine facet loads, pressures, and contact areas in cadaver specimens. Repeatability of measurements in the natural facet joint was determined for five trials of four specimens loaded in pure moment (+/- 7.5 N m) flexibility tests in axial rotation and flexion-extension. Accuracy of load measurements in four joints was assessed by applying known compressive loads of 25, 50, and 100 N to the natural facet joint in a materials testing machine and comparing the known applied load to the measured load. Measurements of load were obtained using two different calibration approaches: linear and two-point calibrations. Repeatability for force, pressure, and area (average of standard deviation as a percentage of the mean for all trials over all specimens) was 4-6% for axial rotation and 7-10% for extension. Peak resultant force in axial rotation was 30% smaller when calculated using the linear calibration method. The Tekscan sensor overestimated the applied force by 18 +/- 9% (mean+/-standard deviation), 35 +/- 7% and 50 +/- 9% for compressive loads of 100, 50, and 25 N, respectively. The two-point method overestimated the loads by 35 +/- 16%, 45 +/- 7%, and 56 +/- 10% for the same three loads. Our results show that the Tekscan sensor is repeatable. However, the sensor measurement range is not optimal for the small loads transmitted by the facets and measurement accuracy is highly dependent on calibration protocol.

  13. Impact of consensus contours from multiple PET segmentation methods on the accuracy of functional volume delineation

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, A. [Saarland University Medical Centre, Department of Nuclear Medicine, Homburg (Germany); Vermandel, M. [U1189 - ONCO-THAI - Image Assisted Laser Therapy for Oncology, University of Lille, Inserm, CHU Lille, Lille (France); CHU Lille, Nuclear Medicine Department, Lille (France); Baillet, C. [CHU Lille, Nuclear Medicine Department, Lille (France); Dewalle-Vignion, A.S. [U1189 - ONCO-THAI - Image Assisted Laser Therapy for Oncology, University of Lille, Inserm, CHU Lille, Lille (France); Modzelewski, R.; Vera, P.; Gardin, I. [Centre Henri-Becquerel and LITIS EA4108, Rouen (France); Massoptier, L.; Parcq, C.; Gibon, D. [AQUILAB, Research and Innovation Department, Loos Les Lille (France); Fechter, T.; Nestle, U. [University Medical Center Freiburg, Department for Radiation Oncology, Freiburg (Germany); German Cancer Consortium (DKTK) Freiburg and German Cancer Research Center (DKFZ), Heidelberg (Germany); Nemer, U. [University Medical Center Freiburg, Department of Nuclear Medicine, Freiburg (Germany)

    2016-05-15

    The aim of this study was to evaluate the impact of consensus algorithms on segmentation results when applied to clinical PET images. In particular, whether the use of the majority vote or STAPLE algorithm could improve the accuracy and reproducibility of the segmentation provided by the combination of three semiautomatic segmentation algorithms was investigated. Three published segmentation methods (contrast-oriented, possibility theory and adaptive thresholding) and two consensus algorithms (majority vote and STAPLE) were implemented in a single software platform (Artiview registered). Four clinical datasets including different locations (thorax, breast, abdomen) or pathologies (primary NSCLC tumours, metastasis, lymphoma) were used to evaluate accuracy and reproducibility of the consensus approach in comparison with pathology as the ground truth or CT as a ground truth surrogate. Variability in the performance of the individual segmentation algorithms for lesions of different tumour entities reflected the variability in PET images in terms of resolution, contrast and noise. Independent of location and pathology of the lesion, however, the consensus method resulted in improved accuracy in volume segmentation compared with the worst-performing individual method in the majority of cases and was close to the best-performing method in many cases. In addition, the implementation revealed high reproducibility in the segmentation results with small changes in the respective starting conditions. There were no significant differences in the results with the STAPLE algorithm and the majority vote algorithm. This study showed that combining different PET segmentation methods by the use of a consensus algorithm offers robustness against the variable performance of individual segmentation methods and this approach would therefore be useful in radiation oncology. It might also be relevant for other scenarios such as the merging of expert recommendations in clinical routine and

  14. Traffic Sign Recognition with High Accuracy Using Mixture of Experts

    Directory of Open Access Journals (Sweden)

    Reza Azad

    2014-06-01

    Full Text Available Traffic signs provide the driver various information for safe and efficient navigation. Automatic recognition of traffic signs is, therefore, important for automated driving or driver assistance systems.In this paper, a new and efficient traffic sign recognition system based on extracting diverse feature set, and applying mixture of experts'architecture on the extracted featuresis proposed.In the result part, the proposed approach is evaluated on the German traffic sign recognition and Grigorescu traffic signsbenchmark and high recognition rate is achieved.Comparison with some of the most related methods indicates that the proposed novel model yields excellent recognition rate in traffic sign recognition that is the recognition rate of 99.94% for the training set and 98.50% for the test set.In addition, experimental results have demonstrated our method robust in successful recognition of traffic signs even with variant lighting.

  15. Ensemble Methods in Data Mining Improving Accuracy Through Combining Predictions

    CERN Document Server

    Seni, Giovanni

    2010-01-01

    This book is aimed at novice and advanced analytic researchers and practitioners -- especially in Engineering, Statistics, and Computer Science. Those with little exposure to ensembles will learn why and how to employ this breakthrough method, and advanced practitioners will gain insight into building even more powerful models. Throughout, snippets of code in R are provided to illustrate the algorithms described and to encourage the reader to try the techniques. The authors are industry experts in data mining and machine learning who are also adjunct professors and popular speakers. Although e

  16. FROM ENERGY IMPROVEMENT TO ACCURACY ENHANCEMENT:IMPROVEMENT OF PLATE BENDING ELEMENTS BY THE COMBINED HYBRID METHOD

    Institute of Scientific and Technical Information of China (English)

    Xiao-ping Xie

    2004-01-01

    By following the geometric point of view in mechanics, a novel expression of the combined hybrid method for plate bending problems is introduced to clarify its intrinsic mechanism of enhancing coarse-mesh accuracy of conforming or nonconforming plate elements.By adjusting the combination parameter α∈ (0, 1) and adopting appropriate bending moments modes, reduction of energy error for the discretized displacement model leads to enhanced numerical accuracy. As an application, improvement of Adini's rectangle is discussed. Numerical experiments show that the combined hybrid counterpart of Adini's element is capable of attaining high accuracy at coarse meshes.

  17. A fast and high accuracy numerical simulation algorithm of the polymer spherulite at the mesoscale Level

    Science.gov (United States)

    Liu, Yongzhi; Geng, Tie; (Tom Turng, Lih-Sheng; Liu, Chuntai; Cao, Wei; Shen, Changyu

    2017-09-01

    In the multiscale numerical simulation of polymer crystallization during the processing period, flow and temperature of the polymer melt are simulated on the macroscale level, while nucleation and growth of the spherulite are simulated at the mesoscale level. As a part of the multiscale simulation, the meso-simulation requires a fast solving speed because the meso-simulation software must be run several times in every macro-element at each macro-step. Meanwhile, the accuracy of the calculation results is also very important. It is known that the simulation geometry of crystallization includes planar (2D) and three-dimensional space (3D). The 3D calculations are more accurate but more expensive because of the long CPU time consumed. On the contrary, 2D calculations are always much faster but lower in accuracy. To reach the desirable speed and high accuracy at the same time, an algorithm is presented, in which the Delesse law coupled with the Monte Carlo method and pixel method are employed to simulate the nucleation, growth, and impingement of the polymer spherulite at the mesoscale level. Based on this algorithm, a software is developed with the Visual C++ language, and its numerical examples’ results prove that the solving speed of this algorithm is as fast as the 2D classical simulation and the calculation accuracy is at the same level as the 3D simulation.

  18. High Accuracy and Real-Time Gated Viewing Laser Radar

    Institute of Scientific and Technical Information of China (English)

    Dong Li; Hua-Jun Yang; Shan-Pei Zhou

    2011-01-01

    A gated viewing laser radar has an excellent performance in underwater low light level imaging,and it also provides a viable solution to inhibit backscattering.In this paper,a gated viewing imaging system according to the demand for real-time imaging is presented,and then the simulation is used to analyze the performance of the real-time gated viewing system.The range accuracy performance is limited by the slice number,the width of gate,the delay time step,the initial delay time,as well as the system noise and atmospheric turbulence.The simulation results indicate that the highest range accuracy can be achieved when the system works with the optimal parameters.Finally,how to choose the optimal parameters has been researched.

  19. Accuracy improvement of a hybrid robot for ITER application using POE modeling method

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yongbo, E-mail: yongbo.wang@hotmail.com [Laboratory of Intelligent Machines, Lappeenranta University of Technology, FIN-53851 Lappeenranta (Finland); Wu, Huapeng; Handroos, Heikki [Laboratory of Intelligent Machines, Lappeenranta University of Technology, FIN-53851 Lappeenranta (Finland)

    2013-10-15

    Highlights: ► The product of exponential (POE) formula for error modeling of hybrid robot. ► Differential Evolution (DE) algorithm for parameter identification. ► Simulation results are given to verify the effectiveness of the method. -- Abstract: This paper focuses on the kinematic calibration of a 10 degree-of-freedom (DOF) redundant serial–parallel hybrid robot to improve its accuracy. The robot was designed to perform the assembling and repairing tasks of the vacuum vessel (VV) of the international thermonuclear experimental reactor (ITER). By employing the product of exponentials (POEs) formula, we extended the POE-based calibration method from serial robot to redundant serial–parallel hybrid robot. The proposed method combines the forward and inverse kinematics together to formulate a hybrid calibration method for serial–parallel hybrid robot. Because of the high nonlinear characteristics of the error model and too many error parameters need to be identified, the traditional iterative linear least-square algorithms cannot be used to identify the parameter errors. This paper employs a global optimization algorithm, Differential Evolution (DE), to identify parameter errors by solving the inverse kinematics of the hybrid robot. Furthermore, after the parameter errors were identified, the DE algorithm was adopted to numerically solve the forward kinematics of the hybrid robot to demonstrate the accuracy improvement of the end-effector. Numerical simulations were carried out by generating random parameter errors at the allowed tolerance limit and generating a number of configuration poses in the robot workspace. Simulation of the real experimental conditions shows that the accuracy of the end-effector can be improved to the same precision level of the given external measurement device.

  20. SNP-based non-invasive prenatal testing detects sex chromosome aneuploidies with high accuracy

    Science.gov (United States)

    Samango-Sprouse, Carole; Banjevic, Milena; Ryan, Allison; Sigurjonsson, Styrmir; Zimmermann, Bernhard; Hill, Matthew; Hall, Megan P.; Westemeyer, Margaret; Saucier, Jennifer; Demko, Zachary; Rabinowitz, Matthew

    2013-01-01

    Objective To develop a single nucleotide polymorphism- and informatics-based non-invasive prenatal test that detects sex chromosome aneuploidies early in pregnancy. Methods Fifteen aneuploid samples, including thirteen 45,X, two 47,XXY, and one 47,XYY, along with 185 euploid controls, were analyzed. Cell-free DNA was isolated from maternal plasma, amplified in a single multiplex PCR assay that targeted 19,488 polymorphic loci covering chromosomes 13, 18, 21, X, and Y, and sequenced. Sequencing results were analyzed using a Bayesian-based maximum likelihood statistical method to determine copy number of interrogated chromosomes, calculating sample-specific accuracies. Results Of the samples that passed a stringent quality control metric (93%), the algorithm correctly identified copy number at all five chromosomes in all 187 samples, for 934/935 correct calls as early as 9.4 weeks of gestation. We detected 45,X with 91.7% sensitivity (CI: 61.5-99.8%) and 100% specificity (CI: 97.9-100%), and 47,XXY and 47,XYY. The average calculated accuracy was 99.78%. Conclusion This method non-invasively detected 45,X, 47,XXY, and 47,XYY fetuses from cfDNA isolated from maternal plasma with high calculated accuracies, and thus offers a non-invasive method with the potential to function as a routine screen allowing for early prenatal detection of rarely diagnosed yet commonly occurring sex aneuploidies. PMID:23712453

  1. Accuracy Analysis for 6-DOF PKM with Sobol Sequence Based Quasi Monte Carlo Method

    Institute of Scientific and Technical Information of China (English)

    Jianguang Li; Jian Ding; Lijie Guo; Yingxue Yao; Zhaohong Yi; Huaijing Jing; Honggen Fang

    2015-01-01

    To improve the precisions of pose error analysis for 6⁃dof parallel kinematic mechanism ( PKM) during assembly quality control, a Sobol sequence based on Quasi Monte Carlo ( QMC) method is introduced and implemented in pose accuracy analysis for the PKM in this paper. The Sobol sequence based on Quasi Monte Carlo with the regularity and uniformity of samples in high dimensions, can prevail traditional Monte Carlo method with up to 98�59% and 98�25% enhancement for computational precision of pose error statistics. Then a PKM tolerance design system integrating this method is developed and with it pose error distributions of the PKM within a prescribed workspace are finally obtained and analyzed.

  2. Accuracy of the Water Vapour Content Measurements in the Atmosphere Using Optical Methods

    CERN Document Server

    Galkin, V D; Alekseeva, G A; Novikov, V V; Pakhomov, V P

    2010-01-01

    This paper describes the accuracy and the errors of water vapour content measurements in the atmosphere using optical methods, especially starphotometer. After the general explanations of the used expressions for the star-magnitude observations of the water vapour absorption in section 3 the absorption model for the water vapour band will be discussed. Sections 4 and 5 give an overview on the technique to determine the model parameters both from spectroscopic laboratory and radiosonde observation data. Finally, the sections 6 and 7 are dealing with the details of the errors; that means errors of observable magnitude, of instrumental extraterrestrial magnitude, of atmospheric extinction determination and of water vapour content determination by radiosonde humidity measurements. The main conclusion is: Because of the high precision of the results the optical methods for water vapour observation are suited to validate and calibrate alternative methods (GPS, LIDAR, MICROWAVE) which are making constant progress wo...

  3. High Accuracy Thermal Expansion Measurement at Cryogenic Temperatures

    Science.gov (United States)

    Tucker, Jim; Despit, Gregory; Stallcup, Michael; Presson, Joan; Nein, Max

    2003-01-01

    A new, interferometer-based system for measuring thermal expansion to an absolute accuracy of 20 ppb or better at cryogenic temperatures has been developed. Data from NIST Copper SRM 736 measured from room temperature to 15 K will be presented along with data from many other materials including beryllium, ULE, Zerodur, and composite materials. Particular attention will be given to a study by the Space Optics Manufacturing Technology Center (SOMTC) investigating the variability of ULE and beryllium materials used in the AMSD program Approximately 20 samples of each material, tested from room temperature to below 30 K are compared as a function of billet location.

  4. Results of error correction techniques applied on two high accuracy coordinate measuring machines

    Energy Technology Data Exchange (ETDEWEB)

    Pace, C.; Doiron, T.; Stieren, D.; Borchardt, B.; Veale, R. (Sandia National Labs., Albuquerque, NM (USA); National Inst. of Standards and Technology, Gaithersburg, MD (USA))

    1990-01-01

    The Primary Standards Laboratory at Sandia National Laboratories (SNL) and the Precision Engineering Division at the National Institute of Standards and Technology (NIST) are in the process of implementing software error correction on two nearly identical high-accuracy coordinate measuring machines (CMMs). Both machines are Moore Special Tool Company M-48 CMMs which are fitted with laser positioning transducers. Although both machines were manufactured to high tolerance levels, the overall volumetric accuracy was insufficient for calibrating standards to the levels both laboratories require. The error mapping procedure was developed at NIST in the mid 1970's on an earlier but similar model. The error mapping procedure was originally very complicated and did not make any assumptions about the rigidness of the machine as it moved, each of the possible error motions was measured at each point of the error map independently. A simpler mapping procedure was developed during the early 1980's which assumed rigid body motion of the machine. This method has been used to calibrate lower accuracy machines with a high degree of success and similar software correction schemes have been implemented by many CMM manufacturers. The rigid body model has not yet been used on highly repeatable CMMs such as the M48. In this report we present early mapping data for the two M48 CMMs. The SNL CMM was manufactured in 1985 and has been in service for approximately four years, whereas the NIST CMM was delivered in early 1989. 4 refs., 5 figs.

  5. Accuracy improvement techniques in Precise Point Positioning method using multiple GNSS constellations

    Science.gov (United States)

    Vasileios Psychas, Dimitrios; Delikaraoglou, Demitris

    2016-04-01

    The future Global Navigation Satellite Systems (GNSS), including modernized GPS, GLONASS, Galileo and BeiDou, offer three or more signal carriers for civilian use and much more redundant observables. The additional frequencies can significantly improve the capabilities of the traditional geodetic techniques based on GPS signals at two frequencies, especially with regard to the availability, accuracy, interoperability and integrity of high-precision GNSS applications. Furthermore, highly redundant measurements can allow for robust simultaneous estimation of static or mobile user states including more parameters such as real-time tropospheric biases and more reliable ambiguity resolution estimates. This paper presents an investigation and analysis of accuracy improvement techniques in the Precise Point Positioning (PPP) method using signals from the fully operational (GPS and GLONASS), as well as the emerging (Galileo and BeiDou) GNSS systems. The main aim was to determine the improvement in both the positioning accuracy achieved and the time convergence it takes to achieve geodetic-level (10 cm or less) accuracy. To this end, freely available observation data from the recent Multi-GNSS Experiment (MGEX) of the International GNSS Service, as well as the open source program RTKLIB were used. Following a brief background of the PPP technique and the scope of MGEX, the paper outlines the various observational scenarios that were used in order to test various data processing aspects of PPP solutions with multi-frequency, multi-constellation GNSS systems. Results from the processing of multi-GNSS observation data from selected permanent MGEX stations are presented and useful conclusions and recommendations for further research are drawn. As shown, data fusion from GPS, GLONASS, Galileo and BeiDou systems is becoming increasingly significant nowadays resulting in a position accuracy increase (mostly in the less favorable East direction) and a large reduction of convergence

  6. Swing arm profilometer: high accuracy testing for large reaction-bonded silicon carbide optics with a capacitive probe

    Science.gov (United States)

    Xiong, Ling; Luo, Xiao; Hu, Hai-xiang; Zhang, Zhi-yu; Zhang, Feng; Zheng, Li-gong; Zhang, Xue-jun

    2017-08-01

    A feasible way to improve the manufacturing efficiency of large reaction-bonded silicon carbide optics is to increase the processing accuracy in the ground stage before polishing, which requires high accuracy metrology. A swing arm profilometer (SAP) has been used to measure large optics during the ground stage. A method has been developed for improving the measurement accuracy of SAP using a capacitive probe and implementing calibrations. The experimental result compared with the interferometer test shows the accuracy of 0.068 μm in root-mean-square (RMS) and maps in 37 low-order Zernike terms show accuracy of 0.048 μm RMS, which shows a powerful capability to provide a major input in high-precision grinding.

  7. High Accuracy, Two-Dimensional Read-Out in Multiwire Proportional Chambers

    Science.gov (United States)

    Charpak, G.; Sauli, F.

    1973-02-14

    In most applications of proportional chambers, especially in high-energy physics, separate chambers are used for measuring different coordinates. In general one coordinate is obtained by recording the pulses from the anode wires around which avalanches have grown. Several methods have been imagined for obtaining the position of an avalanche along a wire. In this article a method is proposed which leads to the same range of accuracies and may be preferred in some cases. The problem of accurate measurements for large-size chamber is also discussed.

  8. Design of a high linearity and high gain accuracy analog baseband circuit for DAB receiver

    Science.gov (United States)

    Li, Ma; Zhigong, Wang; Jian, Xu; Yiqiang, Wu; Junliang, Wang; Mi, Tian; Jianping, Chen

    2015-02-01

    An analog baseband circuit of high linearity and high gain accuracy for a digital audio broadcasting receiver is implemented in a 0.18-μm RFCMOS process. The circuit comprises a 3rd-order active-RC complex filter (CF) and a programmable gain amplifier (PGA). An automatic tuning circuit is also designed to tune the CF's pass band. Instead of the class-A fully differential operational amplifier (FDOPA) adopted in the conventional CF and PGA design, a class-AB FDOPA is specially employed in this circuit to achieve a higher linearity and gain accuracy for its large current swing capability with lower static current consumption. In the PGA circuit, a novel DC offset cancellation technique based on the MOS resistor is introduced to reduce the settling time significantly. A reformative switching network is proposed, which can eliminate the switch resistor's influence on the gain accuracy of the PGA. The measurement result shows the gain range of the circuit is 10-50 dB with a 1-dB step size, and the gain accuracy is less than ±0.3 dB. The OIP3 is 23.3 dBm at the gain of 10 dB. Simulation results show that the settling time is reduced from 100 to 1 ms. The image band rejection is about 40 dB. It only draws 4.5 mA current from a 1.8 V supply voltage.

  9. Frequency Comparison of Two High-Accuracy Al+ Optical Clocks

    CERN Document Server

    Chou, C -W; Koelemeij, J C J; Wineland, D J; Rosenband, T

    2009-01-01

    We have constructed an optical clock with a fractional frequency inaccuracy of 8.6e-18, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser-cool the Al+ ion and detect its quantum state. The frequency of the 1S0->3P0 clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0e-18. The two clocks exhibit a relative stability of 2.8e-15/ sqrt(tau), and a fractional frequency difference of -1.8e-17, consistent with the accuracy limit of the older clock.

  10. Frequency Comparison of Two High-Accuracy Al+ Optical Clocks

    Science.gov (United States)

    Chou, C. W.; Hume, D. B.; Koelemeij, J. C. J.; Wineland, D. J.; Rosenband, T.

    2010-02-01

    We have constructed an optical clock with a fractional frequency inaccuracy of 8.6×10-18, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the S01↔P03 clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0×10-18. The two clocks exhibit a relative stability of 2.8×10-15τ-1/2, and a fractional frequency difference of -1.8×10-17, consistent with the accuracy limit of the older clock.

  11. Spatial distribution of soil heavy metal pollution estimated by different interpolation methods: accuracy and uncertainty analysis.

    Science.gov (United States)

    Xie, Yunfeng; Chen, Tong-bin; Lei, Mei; Yang, Jun; Guo, Qing-jun; Song, Bo; Zhou, Xiao-yong

    2011-01-01

    Mapping the spatial distribution of contaminants in soils is the basis of pollution evaluation and risk control. Interpolation methods are extensively applied in the mapping processes to estimate the heavy metal concentrations at unsampled sites. The performances of interpolation methods (inverse distance weighting, local polynomial, ordinary kriging and radial basis functions) were assessed and compared using the root mean square error for cross validation. The results indicated that all interpolation methods provided a high prediction accuracy of the mean concentration of soil heavy metals. However, the classic method based on percentages of polluted samples, gave a pollution area 23.54-41.92% larger than that estimated by interpolation methods. The difference in contaminated area estimation among the four methods reached 6.14%. According to the interpolation results, the spatial uncertainty of polluted areas was mainly located in three types of region: (a) the local maxima concentration region surrounded by low concentration (clean) sites, (b) the local minima concentration region surrounded with highly polluted samples; and (c) the boundaries of the contaminated areas.

  12. High Accuracy Attitude Control System Design for Satellite with Flexible Appendages

    Directory of Open Access Journals (Sweden)

    Wenya Zhou

    2014-01-01

    Full Text Available In order to realize the high accuracy attitude control of satellite with flexible appendages, attitude control system consisting of the controller and structural filter was designed. When the low order vibration frequency of flexible appendages is approximating the bandwidth of attitude control system, the vibration signal will enter the control system through measurement device to bring impact on the accuracy or even the stability. In order to reduce the impact of vibration of appendages on the attitude control system, the structural filter is designed in terms of rejecting the vibration of flexible appendages. Considering the potential problem of in-orbit frequency variation of the flexible appendages, the design method for the adaptive notch filter is proposed based on the in-orbit identification technology. Finally, the simulation results are given to demonstrate the feasibility and effectiveness of the proposed design techniques.

  13. Reduced conductivity dependence method for increase of dipole localization accuracy in the EEG inverse problem.

    Science.gov (United States)

    Yitembe, Bertrand Russel; Crevecoeur, Guillaume; Van Keer, Roger; Dupre, Luc

    2011-05-01

    The EEG is a neurological diagnostic tool with high temporal resolution. However, when solving the EEG inverse problem, its localization accuracy is limited because of noise in measurements and available uncertainties of the conductivity value in the forward model evaluations. This paper proposes the reduced conductivity dependence (RCD) method for decreasing the localization error in EEG source analysis by limiting the propagation of the uncertain conductivity values to the solutions of the inverse problem. We redefine the traditional EEG cost function, and in contrast to previous approaches, we introduce a selection procedure of the EEG potentials. The selected potentials are, as low as possible, affected by the uncertainties of the conductivity when solving the inverse problem. We validate the methodology on the widely used three-shell spherical head model with a single electrical dipole and multiple dipoles as source model. The proposed RCD method enhances the source localization accuracy with a factor ranging between 2 and 4, dependent on the dipole location and the noise in measurements. © 2011 IEEE

  14. Power Series Approximation for the Correlation Kernel Leading to Kohn-Sham Methods Combining Accuracy, Computational Efficiency, and General Applicability

    Science.gov (United States)

    Erhard, Jannis; Bleiziffer, Patrick; Görling, Andreas

    2016-09-01

    A power series approximation for the correlation kernel of time-dependent density-functional theory is presented. Using this approximation in the adiabatic-connection fluctuation-dissipation (ACFD) theorem leads to a new family of Kohn-Sham methods. The new methods yield reaction energies and barriers of unprecedented accuracy and enable a treatment of static (strong) correlation with an accuracy of high-level multireference configuration interaction methods but are single-reference methods allowing for a black-box-like handling of static correlation. The new methods exhibit a better scaling of the computational effort with the system size than rivaling wave-function-based electronic structure methods. Moreover, the new methods do not suffer from the problem of singularities in response functions plaguing previous ACFD methods and therefore are applicable to any type of electronic system.

  15. Potential of accuracy profile for method validation in inductively coupled plasma spectrochemistry

    Science.gov (United States)

    Mermet, J. M.; Granier, G.

    2012-10-01

    Method validation is usually performed over a range of concentrations for which analytical criteria must be verified. One important criterion in quantitative analysis is accuracy, i.e. the contribution of both trueness and precision. The study of accuracy over this range is called an accuracy profile and provides experimental tolerance intervals. Comparison with acceptability limits fixed by the end user defines a validity domain. This work describes the computation involved in the building of the tolerance intervals, particularly for the intermediate precision with within-laboratory experiments and for the reproducibility with interlaboratory studies. Computation is based on ISO 5725-4 and on previously published work. Moreover, the bias uncertainty is also computed to verify the bias contribution to accuracy. The various types of accuracy profile behavior are exemplified with results obtained by using ICP-MS and ICP-AES. This procedure allows the analyst to define unambiguously a validity domain for a given accuracy. However, because the experiments are time-consuming, the accuracy profile method is mainly dedicated to method validation.

  16. [Influence of interpolation method and sampling number on spatial prediction accuracy of soil Olsen-P].

    Science.gov (United States)

    Sun, Yi-xiang; Wu, Chuan-zhou; Zhu, Ke-bao; Cui, Zhen-ling; Chen, Xin-ping; Zhang, Fu-suo

    2009-03-01

    Different from the large scale farm management in Europe and America, the scattered farmland management in China made the spatial variability of soil nutrients at county scale in this country more challenging. Taking soil Olsen-P in Wuhu County as an example, the influence of interpolation method and sampling number on the spatial prediction accuracy of soil nutrients was evaluated systematically. The results showed that local polynomial method, ordinary kriging, simple kriging, and disjunctive kriging had higher spatial prediction accuracy than the other interpolation methods. Considering of its simplicity, ordinary kriging was recommended to evaluate the spatial variability of soil Olsen-P within a county. The spatial prediction accuracy would increase with increasing soil sampling number. Taking the spatial prediction accuracy and soil sampling cost into consideration, the optimal sampling number should be from 500 to 1000 to evaluate the spatial variability of soil Olsen-P at county scale.

  17. Comparison of whole genome prediction accuracy across generations using parametric and semi parametric methods

    Directory of Open Access Journals (Sweden)

    Abbas Atefi

    2016-11-01

    Full Text Available Accuracy of genomic prediction was compared using three parametric and semi parametric methods, including BayesA, Bayesian LASSO and Reproducing kernel Hilbert spaces regression under various levels of heritability (0.15, 0.3 and 0.45, different number of markers (500, 750 and 1000 and generation intervals of validating set. A historical population of 1000 individuals with equal sex ratio was simulated for 100 generations at constant size. It followed by 100 extra generations of gradually reducing size down to 500 individuals in generation 200. Individuals of generation 200 were mated randomly for 10 more generations applying litter size of 5 to expand the historical generation. Finally, 50 males and 500 females chosen from generation 210 were randomly mated to generate 10 more generations of recent population. Individuals born in generation 211 considered as the training set while the validation set was composed of individuals either from generations 213, 215 or 217. The genome comprised one chromosome of 100 cM length carrying 50 QTLs. There was no significant difference between accuracy of investigated methods (p > 0.05 but among three methods, the highest mean accuracy (0.659 was observed for BayesA. By increasing the heritability, the average genomic accuracy increased from 0.53 to 0.75 (p < 0.05. The number of SNPs affected the accuracy and accuracies increased as number of SNPs increased; therefore, the highest accuracy was for the case number of SNPs=1000. With getting away from validating set, the accuracies decreased and the most severe decay observed in the case of low heritability. Decreasing the accuracy across generations affected by marker density but was independent from investigated methods.

  18. Ultra-high accuracy optical testing: creating diffraction-limitedshort-wavelength optical systems

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Kenneth A.; Naulleau, Patrick P.; Rekawa, Senajith B.; Denham, Paul E.; Liddle, J. Alexander; Gullikson, Eric M.; Jackson, KeithH.; Anderson, Erik H.; Taylor, John S.; Sommargren, Gary E.; Chapman,Henry N.; Phillion, Donald W.; Johnson, Michael; Barty, Anton; Soufli,Regina; Spiller, Eberhard A.; Walton, Christopher C.; Bajt, Sasa

    2005-08-03

    Since 1993, research in the fabrication of extreme ultraviolet (EUV) optical imaging systems, conducted at Lawrence Berkeley National Laboratory (LBNL) and Lawrence Livermore National Laboratory (LLNL), has produced the highest resolution optical systems ever made. We have pioneered the development of ultra-high-accuracy optical testing and alignment methods, working at extreme ultraviolet wavelengths, and pushing wavefront-measuring interferometry into the 2-20-nm wavelength range (60-600 eV). These coherent measurement techniques, including lateral shearing interferometry and phase-shifting point-diffraction interferometry (PS/PDI) have achieved RMS wavefront measurement accuracies of 0.5-1-{angstrom} and better for primary aberration terms, enabling the creation of diffraction-limited EUV optics. The measurement accuracy is established using careful null-testing procedures, and has been verified repeatedly through high-resolution imaging. We believe these methods are broadly applicable to the advancement of short-wavelength optical systems including space telescopes, microscope objectives, projection lenses, synchrotron beamline optics, diffractive and holographic optics, and more. Measurements have been performed on a tunable undulator beamline at LBNL's Advanced Light Source (ALS), optimized for high coherent flux; although many of these techniques should be adaptable to alternative ultraviolet, EUV, and soft x-ray light sources. To date, we have measured nine prototype all-reflective EUV optical systems with NA values between 0.08 and 0.30 (f/6.25 to f/1.67). These projection-imaging lenses were created for the semiconductor industry's advanced research in EUV photolithography, a technology slated for introduction in 2009-13. This paper reviews the methods used and our program's accomplishments to date.

  19. High-accuracy thickness measurement of a transparent plate with the heterodyne central fringe identification technique

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Wang-Tsung; Hsieh, Hung-Chih; Chang, Wei-Yao; Chen, Yen-Liang; Su, Der-Chin

    2011-07-20

    In a modified Twyman-Green interferometer, the optical path variation is measured with the heterodyne central fringe identification technique, as the light beam is focused by a displaced microscopic objective on the front/rear surface of the test transparent plate. The optical path length variation is then measured similarly after the test plate is removed. The geometrical thickness of the test plate can be calculated under the consideration of dispersion effect. This method has a wide measurable range and a high accuracy in the measurable range.

  20. Distributed High Accuracy Peer-to-Peer Localization in Mobile Multipath Environments

    CERN Document Server

    Ekambaram, Venkatesan

    2010-01-01

    In this paper we consider the problem of high accuracy localization of mobile nodes in a multipath-rich environment where sub-meter accuracies are required. We employ a peer to peer framework where the vehicles/nodes can get pairwise multipath-degraded ranging estimates in local neighborhoods together with a fixed number of anchor nodes. The challenge is to overcome the multipath-barrier with redundancy in order to provide the desired accuracies especially under severe multipath conditions when the fraction of received signals corrupted by multipath is dominating. We invoke a message passing analytical framework based on particle filtering and reveal its high accuracy localization promise through simulations.

  1. High accuracy semidefinite programming bounds for kissing numbers

    NARCIS (Netherlands)

    Mittelmann, H.D.; Vallentin, F.

    2009-01-01

    The kissing number in n-dimensional Euclidean space is the maximal number of non-overlapping unit spheres which simultaneously can touch a central unit sphere. Bachoc and Vallentin developed a method to find upper bounds for the kissing number based on semidefinite programming. This paper is a repor

  2. High accuracy semidefinite programming bounds for kissing numbers

    NARCIS (Netherlands)

    H.D. Mittelmann; F. Vallentin (Frank)

    2010-01-01

    htmlabstractThe kissing number in n-dimensional Euclidean space is the maximal number of non-overlapping unit spheres which simultaneously can touch a central unit sphere. Bachoc and Vallentin developed a method to find upper bounds for the kissing number based on semidefinite programming. This

  3. High accuracy semidefinite programming bounds for kissing numbers

    NARCIS (Netherlands)

    H.D. Mittelmann; F. Vallentin (Frank)

    2009-01-01

    htmlabstractThe kissing number in n-dimensional Euclidean space is the maximal number of non-overlapping unit spheres which simultaneously can touch a central unit sphere. Bachoc and Vallentin developed a method to find upper bounds for the kissing number based on semidefinite programming. This

  4. High-accuracy Subdaily ERPs from the IGS

    Science.gov (United States)

    Ray, J. R.; Griffiths, J.

    2012-04-01

    Since November 2000 the International GNSS Service (IGS) has published Ultra-rapid (IGU) products for near real-time (RT) and true real-time applications. They include satellite orbits and clocks, as well as Earth rotation parameters (ERPs) for a sliding 48-hr period. The first day of each update is based on the most recent GPS and GLONASS observational data from the IGS hourly tracking network. At the time of release, these observed products have an initial latency of 3 hr. The second day of each update consists of predictions. So the predictions between about 3 and 9 hr into the second half are relevant for true RT uses. Originally updated twice daily, the IGU products since April 2004 have been issued every 6 hr, at 3, 9, 15, and 21 UTC. Up to seven Analysis Centers (ACs) contribute to the IGU combinations. Two sets of ERPs are published with each IGU update, observed values at the middle epoch of the first half and predicted values at the middle epoch of the second half. The latency of the near RT ERPs is 15 hr while the predicted ERPs, based on projections of each AC's most recent determinations, are issued 9 hr ahead of their reference epoch. While IGU ERPs are issued every 6 hr, each set represents an integrated estimate over the surrounding 24 hr. So successive values are temporally correlated with about 75% of the data being common; this fact should be taken into account in user assimilations. To evaluate the accuracy of these near RT and predicted ERPs, they have been compared to the IGS Final ERPs, available about 11 to 17 d after data collection. The IGU products improved dramatically in the earlier years but since about 2008.0 the performance has been stable and excellent. During the last three years, RMS differences for the observed IGU ERPs have been about 0.036 mas and 0.0101 ms for each polar motion component and LOD respectively. (The internal precision of the reference IGS ERPs over the same period is about 0.016 mas for polar motion and 0

  5. A study for high accuracy real-time 3D ultrasonic location system.

    Science.gov (United States)

    Zhou, Ping; Ha, Zhang; Zhou, Kangyuan

    2006-12-22

    We discussed a high accuracy real-time 3D ultrasonic location system in this article. The signal received was sampled after it passed the TGC and the logarithmic amplifier. Inside the DSP, we used the dynamic threshold tracing technique to improve the accuracy. The result was processed with Weighted Arithmetic Average. By testing the 40 kHz 3D location system, we have arrived at the accuracy of 1 cm.

  6. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior st

  7. High accuracy measurements of magnetic field integrals for the european XFEL undulator systems

    Science.gov (United States)

    Wolff-Fabris, Frederik; Viehweger, Marc; Li, Yuhui; Pflüger, Joachim

    2016-10-01

    Two high accuracy moving wire (MW) measurement systems based on stretched wire technique were built for the European XFEL (XFEL.EU). They were dedicated to monitor, tune and improve the magnetic field integrals properties during the serial production of the undulator segments, phase shifters and air coil correctors for XFEL.EU. For the magnetic tuning of phase shifters and the calibration of the air coils correctors a short portable MW measurement bench was built to measure first field integrals in short devices with magnetic length of less than about 300 mm and with an ultimate accuracy much better than 1 G cm (0.001 T mm). A long MW measurement setup was dedicated to obtain the total first and second field integrals on the 5-meters long undulator segments with accuracy of about 4 G cm (0.004 T mm) and 2000 G cm2 (20 T mm2) for the 1st and 2nd field integrals, respectively. Using these data a method was developed to compute the proper corrections for the air coils correctors used at both extremities so that zero first and second field integrals for an undulator segment are obtained. It is demonstrated that charging air coils correctors with these corrections results in near zero effect to the electron trajectory in the undulator systems and consequently no negative impact on the self-amplified spontaneous emission (SASE) process should occur.

  8. Using Mobile Laser Scanning Data for Features Extraction of High Accuracy Driving Maps

    Science.gov (United States)

    Yang, Bisheng; Liu, Yuan; Liang, Fuxun; Dong, Zhen

    2016-06-01

    High Accuracy Driving Maps (HADMs) are the core component of Intelligent Drive Assistant Systems (IDAS), which can effectively reduce the traffic accidents due to human error and provide more comfortable driving experiences. Vehicle-based mobile laser scanning (MLS) systems provide an efficient solution to rapidly capture three-dimensional (3D) point clouds of road environments with high flexibility and precision. This paper proposes a novel method to extract road features (e.g., road surfaces, road boundaries, road markings, buildings, guardrails, street lamps, traffic signs, roadside-trees, power lines, vehicles and so on) for HADMs in highway environment. Quantitative evaluations show that the proposed algorithm attains an average precision and recall in terms of 90.6% and 91.2% in extracting road features. Results demonstrate the efficiencies and feasibilities of the proposed method for extraction of road features for HADMs.

  9. Multiple Staggered Mesh Ewald: Boosting the Accuracy of the Smooth Particle Mesh Ewald Method

    CERN Document Server

    Wang, Han; Fang, Jun

    2016-01-01

    The smooth particle mesh Ewald (SPME) method is the standard method for computing the electrostatic interactions in the molecular simulations. In this work, the multiple staggered mesh Ewald (MSME) method is proposed to boost the accuracy of the SPME method. Unlike the SPME that achieves higher accuracy by refining the mesh, the MSME improves the accuracy by averaging the standard SPME forces computed on, e.g. $M$, staggered meshes. We prove, from theoretical perspective, that the MSME is as accurate as the SPME, but uses $M^2$ times less mesh points in a certain parameter range. In the complementary parameter range, the MSME is as accurate as the SPME with twice of the interpolation order. The theoretical conclusions are numerically validated both by a uniform and uncorrelated charge system, and by a three-point-charge water system that is widely used as solvent for the bio-macromolecules.

  10. COARSE-MESH-ACCURACY IMPROVEMENT OF BILINEAR Q4-PLANE ELEMENT BY THE COMBINED HYBRID FINITE ELEMENT METHOD

    Institute of Scientific and Technical Information of China (English)

    谢小平; 周天孝

    2003-01-01

    The combined hybrid finite element method is of an intrinsic mechanism of enhancing coarse-mesh-accuracy of lower order displacement schemes. It was confirmed that the combined hybrid scheme without energy error leads to enhancement of accuracy at coarse meshes, and that the combination parameter plays an important role in the enhancement. As an improvement of conforming bilinear Q4-plane element, the combined hybrid method adopted the most convenient quadrilateral displacements-stress mode, i. e.,the mode of compatible isoparametric bilinear displacements and pure constant stresses. By adjusting the combined parameter, the optimized version of the combined hybrid element was obtained and numerical tests indicated that this parameter-adjusted version behaves much better than Q4-element and is of high accuracy at coarse meshes. Due to elimination of stress parameters at the elemental level, this combined hybrid version is of the same computational cost as that of Q4 -element.

  11. Tank Fire Control Systems Accuracy Assignment Based on Fuzzy Comprehensive Judgment Method

    Institute of Scientific and Technical Information of China (English)

    刘文果; 陈杰; 窦丽华

    2003-01-01

    A method of accuracy assignment based on fuzzy comprehensive judgment method (FCJM) in tank fire control system is proposed. From the flowing route of the error sources and their respective correlative signals, the transfer functions of several sources are analysed by means of mathematic simulation, and FCJM is applied to obtain the cost comprehensive factor for each part of system, combining its error sensitivity factor the mathematical model is built to solve the accuracy assignment problem. Simulation result shows the proposed method can help designer of tank fire control system work out an optimal system more efficiently and more economically.

  12. The Matrix Element Method at next-to-leading order accuracy

    CERN Document Server

    Martini, Till

    2015-01-01

    The Matrix Element Method (MEM) has proven beneficial to make maximal use of the information available in experimental data. However, so far it has mostly been used in Born approximation only. In this paper we discuss an extension to NLO accuracy. As a prerequisite we present an efficient method to calculate event weights for jet events at NLO accuracy. As illustration and proof of concept we apply the method to the extraction of the top-quark mass in e+e- annihilation. We observe significant differences when moving from LO to NLO which may be relevant for the interpretation of top-quark mass measurements at hadron colliders relying on the MEM.

  13. Accuracy of two geocoding methods for geographic information system-based exposure assessment in epidemiological studies.

    Science.gov (United States)

    Faure, Elodie; Danjou, Aurélie M N; Clavel-Chapelon, Françoise; Boutron-Ruault, Marie-Christine; Dossus, Laure; Fervers, Béatrice

    2017-02-24

    Environmental exposure assessment based on Geographic Information Systems (GIS) and study participants' residential proximity to environmental exposure sources relies on the positional accuracy of subjects' residences to avoid misclassification bias. Our study compared the positional accuracy of two automatic geocoding methods to a manual reference method. We geocoded 4,247 address records representing the residential history (1990-2008) of 1,685 women from the French national E3N cohort living in the Rhône-Alpes region. We compared two automatic geocoding methods, a free-online geocoding service (method A) and an in-house geocoder (method B), to a reference layer created by manually relocating addresses from method A (method R). For each automatic geocoding method, positional accuracy levels were compared according to the urban/rural status of addresses and time-periods (1990-2000, 2001-2008), using Chi Square tests. Kappa statistics were performed to assess agreement of positional accuracy of both methods A and B with the reference method, overall, by time-periods and by urban/rural status of addresses. Respectively 81.4% and 84.4% of addresses were geocoded to the exact address (65.1% and 61.4%) or to the street segment (16.3% and 23.0%) with methods A and B. In the reference layer, geocoding accuracy was higher in urban areas compared to rural areas (74.4% vs. 10.5% addresses geocoded to the address or interpolated address level, p < 0.0001); no difference was observed according to the period of residence. Compared to the reference method, median positional errors were 0.0 m (IQR = 0.0-37.2 m) and 26.5 m (8.0-134.8 m), with positional errors <100 m for 82.5% and 71.3% of addresses, for method A and method B respectively. Positional agreement of method A and method B with method R was 'substantial' for both methods, with kappa coefficients of 0.60 and 0.61 for methods A and B, respectively. Our study demonstrates the feasibility of geocoding

  14. Cavity ring-down technique for measurement of reflectivity of high reflectivity mirrors with high accuracy

    Indian Academy of Sciences (India)

    G Sridhar; Sandeep K Agarwalla; Sunita Singh; L M Gantayet

    2010-12-01

    A simple, accurate and reliable method for measuring the reflectivity of laser-grade mirrors ( > 99.5 %) based on cavity ring-down (CRD) technique has been success-fully demonstrated in our laboratory using a pulsed Nd:YAG laser. A fast photomultiplier tube with an oscilloscope was used to detect and analyse the CRD signal. The cavity decay times were measured for three cavities formed by a combination of three mirror pairs. The absolute reflectivities 1, 2, 3 were determined to be 99.94%, 99.63%, 99.52% at normal incidence. The reflectivity of mirrors is measured to an accuracy of 0.01%.

  15. High accuracy magnetic field sensors with wide operation temperature range

    Science.gov (United States)

    Vasil'evskii, I. S.; Vinichenko, A. N.; Rubakin, D. I.; Bolshakova, I. A.; Kargin, N. I.

    2016-10-01

    n+InAs(Si) epitaxial thin films heavily doped by silicon and Hall effect magnetic field sensors based on this structures have been fabricated and studied. We have demonstrated the successful formation of highly doped InAs thin films (∼100 nm) with the different intermediate layer arrangement and appropriate electron mobility values. Hall sensors performance parameters have been measured in wide temperature range. Obtained sensitivity varied from 1 to 40 Ω/T, while the best linearity and lower temperature coefficient have been found in the higher doped samples with lower electron mobility. We attribute this to the electron system degeneracy and decreased phonon contribution to electron mobility and resistance.

  16. Study on the accuracy of comprehensive evaluating method based on fuzzy set theory

    Institute of Scientific and Technical Information of China (English)

    Xu Weixiang; Liu Xumin

    2005-01-01

    The evaluation method and its accuracy for evaluating complex systems are considered. In order to evaluate accurately complex systems, the existed evaluating methods are simply analyzed, and a new comprehensive evaluating method is developed. The new method is integration of Delphi approach, analytic hierarchy process, gray interconnect degree and fuzzy evaluation (DHGF). Its theory foundation is the meta-synthesis methodology from qualitative analysis to quantitative analysis. According to fuzzy set approach, using the methods of concordance of evaluation, redundant verify, double models redundant, and limitations of the method etc, the accuracy of evaluating method of DHGF is estimated, and a practical example is given. The result shows that using the method to evaluate complex system projects is feasible and credible.

  17. Gated viewing and high-accuracy three-dimensional laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a fast and high-accuracy three-dimensional (3-D) imaging laser radar that can achieve better than 1 mm range accuracy for half a million pixels in less than 1 s. Our technique is based on range-gating segmentation. We combine the advantages of gated viewing with our new fast...

  18. Gated viewing and high-accuracy three-dimensional laser radar

    DEFF Research Database (Denmark)

    Busck, Jens; Heiselberg, Henning

    2004-01-01

    We have developed a fast and high-accuracy three-dimensional (3-D) imaging laser radar that can achieve better than 1 mm range accuracy for half a million pixels in less than 1 s. Our technique is based on range-gating segmentation. We combine the advantages of gated viewing with our new fast...

  19. A High-Throughput, High-Accuracy System-Level Simulation Framework for System on Chips

    Directory of Open Access Journals (Sweden)

    Guanyi Sun

    2011-01-01

    Full Text Available Today's System-on-Chips (SoCs design is extremely challenging because it involves complicated design tradeoffs and heterogeneous design expertise. To explore the large solution space, system architects have to rely on system-level simulators to identify an optimized SoC architecture. In this paper, we propose a system-level simulation framework, System Performance Simulation Implementation Mechanism, or SPSIM. Based on SystemC TLM2.0, the framework consists of an executable SoC model, a simulation tool chain, and a modeling methodology. Compared with the large body of existing research in this area, this work is aimed at delivering a high simulation throughput and, at the same time, guaranteeing a high accuracy on real industrial applications. Integrating the leading TLM techniques, our simulator can attain a simulation speed that is not slower than that of the hardware execution by a factor of 35 on a set of real-world applications. SPSIM incorporates effective timing models, which can achieve a high accuracy after hardware-based calibration. Experimental results on a set of mobile applications proved that the difference between the simulated and measured results of timing performance is within 10%, which in the past can only be attained by cycle-accurate models.

  20. On the accuracy of the high redshift cluster luminosity function

    CERN Document Server

    Muñoz, Roberto P; Barrientos, Luis F

    2008-01-01

    We study the reliability of the statistical background subtraction method for computing the Ks-band luminosity function of cluster galaxies at z~1 using mock Red-sequence Cluster Survey cluster catalogues constructed from GALFORM semi-analytic galaxies. The underlying cluster luminosity function in the mocks are compatible with recent estimates at z~1 by several authors. We simulate different samples where the number of clusters with Ks-band photometry goes from 5 to a maximum of 50, in order to find the most suitable observational sample to carry out this study; the current observational status in the nIR wavelength range has been reached using 5 real clusters at z~1. We compute the composite luminosity function for several samples of galaxy clusters with masses 1.5x10^14 M_sun assuming a flux limited, complete sample of galaxies down to Ks=21.0 magnitudes. We find that the Schechter fit parameters Ks* and alpha for a sample of galaxies with no redshift information are rather poorly constrained if both param...

  1. Multi-grid finite element method used for enhancing the reconstruction accuracy in Cerenkov luminescence tomography

    Science.gov (United States)

    Guo, Hongbo; He, Xiaowei; Liu, Muhan; Zhang, Zeyu; Hu, Zhenhua; Tian, Jie

    2017-03-01

    Cerenkov luminescence tomography (CLT), as a promising optical molecular imaging modality, can be applied to cancer diagnostic and therapeutic. Most researches about CLT reconstruction are based on the finite element method (FEM) framework. However, the quality of FEM mesh grid is still a vital factor to restrict the accuracy of the CLT reconstruction result. In this paper, we proposed a multi-grid finite element method framework, which was able to improve the accuracy of reconstruction. Meanwhile, the multilevel scheme adaptive algebraic reconstruction technique (MLS-AART) based on a modified iterative algorithm was applied to improve the reconstruction accuracy. In numerical simulation experiments, the feasibility of our proposed method were evaluated. Results showed that the multi-grid strategy could obtain 3D spatial information of Cerenkov source more accurately compared with the traditional single-grid FEM.

  2. INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION

    Directory of Open Access Journals (Sweden)

    Mario Dobrilović

    2014-12-01

    Full Text Available In addition to other detonation parameters detonation velocity is a value that provides indirect information on the strength i.e. brisance of an explosive and explosive performance. In addition to that, detonation velocity is a value which can be measured in a relatively simpler and more precise manner, by developed and accessible methods when compared to other detonation parameters Due to its simple use, compact instruments and satisfactory accuracy, electro-optical method of detonation velocity measurement is widely used. The paper describes the electro-optical measurement method and points out the factors that affect its accuracy. The accuracy of measurement is increased and measurement uncertainty is reduced by the measurement result analysis with the application of different measurement setups.

  3. The accuracy of QCD perturbation theory at high energies

    CERN Document Server

    Dalla Brida, Mattia; Korzec, Tomasz; Ramos, Alberto; Sint, Stefan; Sommer, Rainer

    2016-01-01

    We discuss the determination of the strong coupling $\\alpha_\\mathrm{\\overline{MS}}^{}(m_\\mathrm{Z})$ or equivalently the QCD $\\Lambda$-parameter. Its determination requires the use of perturbation theory in $\\alpha_s(\\mu)$ in some scheme, $s$, and at some energy scale $\\mu$. The higher the scale $\\mu$ the more accurate perturbation theory becomes, owing to asymptotic freedom. As one step in our computation of the $\\Lambda$-parameter in three-flavor QCD, we perform lattice computations in a scheme which allows us to non-perturbatively reach very high energies, corresponding to $\\alpha_s = 0.1$ and below. We find that perturbation theory is very accurate there, yielding a three percent error in the $\\Lambda$-parameter, while data around $\\alpha_s \\approx 0.2$ is clearly insufficient to quote such a precision. It is important to realize that these findings are expected to be generic, as our scheme has advantageous properties regarding the applicability of perturbation theory.

  4. Simple high-accuracy resolution program for convective modelling of discontinuities

    Science.gov (United States)

    Leonard, B. P.

    1988-01-01

    For steady multidimensional convection, the Quadratic Upstream Interpolation for Convective Kinematics (QUICK) scheme has several attractive properties. However, for highly convective simulation of step profiles, QUICK produces unphysical overshoots and a few oscillations, and this may cause serious problems in nonlinear flows. Fortunately, it is possible to modify the convective flux by writing the normalized convected control-volume face value as a function of the normalized adjacent upstream node value, developing criteria for monotonic resolution without sacrificing formal accuracy. This results in a nonlinear functional relationship between the normalized variables, whereas standard methods are all linear in this sense. The resulting Simple High Accuracy Resolution Program (SHARP) can be applied to steady multidimensional flows containing thin shear or mixing layers, shock waves, and other frontal phenomena. This represents a significant advance in modeling highly convective flows of engineering and geophysical importance. SHARP is based on an explicit, conservative, control-volume flux formation, equally applicable to one, two, or three dimensional elliptic, parabolic, hyperbolic, or mixed-flow regimes. Results are given for the bench-mark purely convective first-order results and the nonmonotonic predictions of second- and third-order upwinding.

  5. High-accuracy optimal finite-thrust trajectories for Moon escape

    Science.gov (United States)

    Shen, Hong-Xin; Casalino, Lorenzo

    2017-02-01

    The optimization problem of fuel-optimal trajectories from a low circular Moon orbit to a target hyperbolic excess velocity vector using finite-thrust propulsion is solved. The ability to obtain the most accurate satisfaction of necessary optimality conditions in a high-accuracy dynamic model is the main motivation of the current study. The solutions allow attaining anytime-return Earth-interface conditions from a low lunar orbit. Gravitational effects of the Sun, Earth, and Moon are included throughout the entire trajectory. Severe constraints on the fuel budget combined with high-accuracy demands on the endpoint conditions necessitate a high-fidelity solution to the trajectory optimization problem and JPL DE405 ephemeris model is used to determine the perturbing bodies' positions. The optimization problem is solved using an indirect method. The optimality of the solution is verified by an application of Pontryagin's maximum principle. More accurate and fuel-efficient trajectories are found for the same mission objectives and constraints published in other research, emphasizing the advantages of this technique. It is also shown that the thrust structure consists of three finite burns. In contrast to previous research, no singular arc is required in the optimal solutions, and all the controls appear bang-bang.

  6. Methodology of High Accuracy and Resolution 3D Geological Model Generation and Application

    Institute of Scientific and Technical Information of China (English)

    吴键; 曹代勇; 邓爱居; 李东津; 蒋涛; 翟光华

    2004-01-01

    By generating a high accuracy and high resolution geological model in Liuchu oil field, the technique of geological modeling is expanded and involved in primary geological study, making the sand bodies and reservoir be easily described in detail. The 3D visualization and 3D interactive editing of geological structure model are the key for modeling procedure. And a high accuracy and resolution geological model has been well applied in optimizing the production scheme.

  7. Scale effect and methods for accuracy evaluation of attribute information loss in rasterization

    Institute of Scientific and Technical Information of China (English)

    BAI Yan; LIAO Shunbao; SUN Jiulin

    2011-01-01

    Rasterization is a conversion process accompanied with information loss,which includes the loss of features' shape,structure,position,attribute and so on.Two chief factors that affect estimating attribute accuracy loss in rasterization are grid cell size and evaluating method.That is,attribute accuracy loss in rasterization has a close relationship with grid cell size; besides,it is also influenced by evaluating methods.Therefore,it is significant to analyze these two influencing factors comprehensively.Taking land cover data of Sichuan at the scale of 1:250,000 in 2005 as a case,in view of data volume and its processing time of the study region,this study selects 16 spatial scales from 600 m to 30 km,uses rasterizing method based on the Rule of Maximum Area (RMA) in ArcGIS and two evaluating methods of attribute accuracy loss,which are Normal Analysis Method (NAM) and a new Method Based on Grid Cell (MBGC),respectively,and analyzes the scale effect of attribute (it is area here) accuracy loss at 16 different scales by these two evaluating methods comparatively.The results show that:(1) At the same scale,average area accuracy loss of the entire study region evaluated by MBGC is significantly larger than the one estimated using NAM.Moreover,this discrepancy between the t.wo is obvious in the range of 1 km to 10 km.When the grid cell is larger than 10 km,average area accuracy losses calculated by the two evaluating methods are stable,even tended to parallel.(2) MBGC can not only estimate RMA rasterization attribute accuracy loss accurately,but can express the spatial distribution of the loss objectively.(3) The suitable scale domain for RMA rasterization of land cover data of Sichuan at the scale of 1:250,000 in 2005 is better equal to or less than 800 m,in which the data volume is favorable and the processing time is not too long,as well as the area accuracy loss is less than 2.5%.

  8. An Universal Modeling Method for Enhancing the Volumetric Accuracy of CNC Machine Tools

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Volumetric error modeling method is an important te ch nique for enhancement the accuracy of CNC machine tools by error compensation. I n the research field, the main question is how to find an universal kinematics m odeling method for different kinds of NC machine tools. Multi-body system theor y is always used to solve the dynamics problem of complex physical system. But t ill now, the error factors that always exist in practice system is still not con sidered. In this paper, the accuracy kinematics of MB...

  9. Estimation of the Accuracy of Method for Quantitative Determination of Volatile Compounds in Alcohol Products

    CERN Document Server

    Charepitsa, S V; Zadreyko, Y V; Sytova, S N

    2016-01-01

    Results of the estimation of the precision for determination volatile compounds in alcohol-containing products by gas chromatography: acetaldehyde, methyl acetate, ethyl acetate, methanol, isopropyl alcohol, propyl alcohol, isobutyl alcohol, butyl alcohol, isoamyl alcohol are presented. To determine the accuracy, measurements were planned in accordance with ISO 5725 and held at the gas chromatograph Crystal-5000. Standard deviation of repeatability, intermediate precision and their limits are derived from obtained experimental data. The uncertainty of the measurements was calculated on the base of an "empirical" method. The obtained values of accuracy indicate that the developed method allows measurement uncertainty extended from 2 to 20% depending on the analyzed compound and measured concentration.

  10. Studies of the accuracy of time integration methods for reaction-diffusion equations

    Science.gov (United States)

    Ropp, David L.; Shadid, John N.; Ober, Curtis C.

    2004-03-01

    In this study we present numerical experiments of time integration methods applied to systems of reaction-diffusion equations. Our main interest is in evaluating the relative accuracy and asymptotic order of accuracy of the methods on problems which exhibit an approximate balance between the competing component time scales. Nearly balanced systems can produce a significant coupling of the physical mechanisms and introduce a slow dynamical time scale of interest. These problems provide a challenging test for this evaluation and tend to reveal subtle differences between the various methods. The methods we consider include first- and second-order semi-implicit, fully implicit, and operator-splitting techniques. The test problems include a prototype propagating nonlinear reaction-diffusion wave, a non-equilibrium radiation-diffusion system, a Brusselator chemical dynamics system and a blow-up example. In this evaluation we demonstrate a "split personality" for the operator-splitting methods that we consider. While operator-splitting methods often obtain very good accuracy, they can also manifest a serious degradation in accuracy due to stability problems.

  11. State of the art in high accuracy high detail DTMs derived from ALS

    Science.gov (United States)

    Pfeifer, N.; Briese, C.; Mandlburger, G.; Höfle, B.; Ressl, C.

    2009-04-01

    High-resolution Digital Terrain Models (DTMs) representing the bare Earth are a fundamental input for various applications in geomorphology. Airborne laser scanning (ALS) is established as a standard tool for deriving DTMs over large areas with unprecedented accuracy. Due to advances in sensor technology and in processing algorithms in the recent years the obtainable accuracy is still increasing. Accuracy is understood as the deviation from the elevation at one specified point to its true value. These advances may lead to a more efficient data acquisition, if reduced accuracy is targeted, but also allow data acquisition schemes with more detail becoming visible, i.e. small features of the relief. For the latter a high internal precision, i.e. repeatability, is necessary. The essential advances in the technologies are improvements in ranging through the introduction of full-waveform (FWF) laser scanning and rigorous models of strip adjustment. In FWF laser scanning the time-dependent strength of the backscattered signal is recorded. This is opposed to the analogue processing of the incoming energy and storage of one arrival time of discrete-return systems. In a simple one-echo situation, the arrival time corresponds to the maximum of the waveform. By applying a decomposition of the full waveform into single echoes, which are transformed copies of the emitted signal, it is possible to retrieve more echoes per shot. Additionally, if echoes of individual scatterers are overlapping, FWF sensors might be able to separate them, whereas discrete return systems might rather only be able to derive one collective arrival time. Finally, the overlay of two echoes does not have the maxima at the same positions as the individual echoes. Additionally, the pulse repetition rate of laser scanners has increased, which allows higher point densities and therefore higher richness of detail. These advances in data acquisition increase the precision within one ALS strip. Deficiencies in

  12. Height Accuracy Based on Different Rtk GPS Method for Ultralight Aircraft Images

    Science.gov (United States)

    Tahar, K. N.

    2015-08-01

    Height accuracy is one of the important elements in surveying work especially for control point's establishment which requires an accurate measurement. There are many methods can be used to acquire height value such as tacheometry, leveling and Global Positioning System (GPS). This study has investigated the effect on height accuracy based on different observations which are single based and network based GPS methods. The GPS network is acquired from the local network namely Iskandar network. This network has been setup to provide real-time correction data to rover GPS station while the single network is based on the known GPS station. Nine ground control points were established evenly at the study area. Each ground control points were observed about two and ten minutes. It was found that, the height accuracy give the different result for each observation.

  13. High Accuracy Liquid Propellant Slosh Predictions Using an Integrated CFD and Controls Analysis Interface

    Science.gov (United States)

    Marsell, Brandon; Griffin, David; Schallhorn, Dr. Paul; Roth, Jacob

    2012-01-01

    Coupling computational fluid dynamics (CFD) with a controls analysis tool elegantly allows for high accuracy predictions of the interaction between sloshing liquid propellants and th e control system of a launch vehicle. Instead of relying on mechanical analogs which are not valid during aU stages of flight, this method allows for a direct link between the vehicle dynamic environments calculated by the solver in the controls analysis tool to the fluid flow equations solved by the CFD code. This paper describes such a coupling methodology, presents the results of a series of test cases, and compares said results against equivalent results from extensively validated tools. The coupling methodology, described herein, has proven to be highly accurate in a variety of different cases.

  14. Integrated CFD and Controls Analysis Interface for High Accuracy Liquid Propellant Slosh Predictions

    Science.gov (United States)

    Marsell, Brandon; Griffin, David; Schallhorn, Paul; Roth, Jacob

    2012-01-01

    Coupling computational fluid dynamics (CFD) with a controls analysis tool elegantly allows for high accuracy predictions of the interaction between sloshing liquid propellants and the control system of a launch vehicle. Instead of relying on mechanical analogs which are n0t va lid during all stages of flight, this method allows for a direct link between the vehicle dynamic environments calculated by the solver in the controls analysis tool to the fluid now equations solved by the CFD code. This paper describes such a coupling methodology, presents the results of a series of test cases, and compares said results against equivalent results from extensively validated tools. The coupling methodology, described herein, has proven to be highly accurate in a variety of different cases.

  15. Factors affecting the accuracy of endoscopic transpapillary sampling methods for bile duct cancer.

    Science.gov (United States)

    Nishikawa, Takao; Tsuyuguchi, Toshio; Sakai, Yuji; Sugiyama, Harutoshi; Tawada, Katsunobu; Mikata, Rintaro; Tada, Motohisa; Ishihara, Takeshi; Miyazaki, Masaru; Yokosuka, Osamu

    2014-03-01

    Various methods for endoscopic transpapillary sampling have been developed. However, the factors affecting the accuracy of these methods for bile duct cancer are unknown. The aim of the present study was to determine the factors affecting the accuracy of endoscopic transpapillary sampling methods. We reviewed the results from 101 patients with bile duct cancer who underwent transpapillary sampling by aspiration bile cytology, brushing cytology, and fluoroscopic forceps biopsy. The final diagnosis of bile duct cancer was made on the basis of pathological evaluation of specimens obtained at surgery and the clinical course over at least 1 year in patients not operated on. We carried out subgroup analyses for the factors affecting the accuracy of each transpapillary sampling method. Aspiration bile cytology was carried out 238 times in 77 patients, brushing cytology was carried out 67 times in 60patients, and fluoroscopic forceps biopsy was carried out 64 times in 53 patients. Accuracies of aspiration bile cytology were significantly higher for longer (≥15 mm) biliary cancerous lesions than for shorter (sampling methods are more accurate for longer or elevated (non-flat) biliary cancerous lesions than for shorter or flat lesions. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  16. PACMAN Project: A New Solution for the High-accuracy Alignment of Accelerator Components

    CERN Document Server

    Mainaud Durand, Helene; Buzio, Marco; Caiazza, Domenico; Catalán Lasheras, Nuria; Cherif, Ahmed; Doytchinov, Iordan; Fuchs, Jean-Frederic; Gaddi, Andrea; Galindo Munoz, Natalia; Gayde, Jean-Christophe; Kamugasa, Solomon; Modena, Michele; Novotny, Peter; Russenschuck, Stephan; Sanz, Claude; Severino, Giordana; Tshilumba, David; Vlachakis, Vasileios; Wendt, Manfred; Zorzetti, Silvia

    2016-01-01

    The beam alignment requirements for the next generation of lepton colliders have become increasingly challenging. As an example, the alignment requirements for the three major collider components of the CLIC linear collider are as follows. Before the first beam circulates, the Beam Position Monitors (BPM), Accelerating Structures (AS)and quadrupoles will have to be aligned up to 10 μm w.r.t. a straight line over 200 m long segments, along the 20 km of linacs. PACMAN is a study on Particle Accelerator Components' Metrology and Alignment to the Nanometre scale. It is an Innovative Doctoral Program, funded by the EU and hosted by CERN, providing high quality training to 10 Early Stage Researchers working towards a PhD thesis. The technical aim of the project is to improve the alignment accuracy of the CLIC components by developing new methods and tools addressing several steps of alignment simultaneously, to gain time and accuracy. The tools and methods developed will be validated on a test bench. This paper pr...

  17. High accuracy genotyping directly from genomic DNA using a rolling circle amplification based assay

    Directory of Open Access Journals (Sweden)

    Du Yuefen

    2003-05-01

    Full Text Available Abstract Background Rolling circle amplification of ligated probes is a simple and sensitive means for genotyping directly from genomic DNA. SNPs and mutations are interrogated with open circle probes (OCP that can be circularized by DNA ligase when the probe matches the genotype. An amplified detection signal is generated by exponential rolling circle amplification (ERCA of the circularized probe. The low cost and scalability of ligation/ERCA genotyping makes it ideally suited for automated, high throughput methods. Results A retrospective study using human genomic DNA samples of known genotype was performed for four different clinically relevant mutations: Factor V Leiden, Factor II prothrombin, and two hemochromatosis mutations, C282Y and H63D. Greater than 99% accuracy was obtained genotyping genomic DNA samples from hundreds of different individuals. The combined process of ligation/ERCA was performed in a single tube and produced fluorescent signal directly from genomic DNA in less than an hour. In each assay, the probes for both normal and mutant alleles were combined in a single reaction. Multiple ERCA primers combined with a quenched-peptide nucleic acid (Q-PNA fluorescent detection system greatly accellerated the appearance of signal. Probes designed with hairpin structures reduced misamplification. Genotyping accuracy was identical from either purified genomic DNA or genomic DNA generated using whole genome amplification (WGA. Fluorescent signal output was measured in real time and as an end point. Conclusions Combining the optimal elements for ligation/ERCA genotyping has resulted in a highly accurate single tube assay for genotyping directly from genomic DNA samples. Accuracy exceeded 99 % for four probe sets targeting clinically relevant mutations. No genotypes were called incorrectly using either genomic DNA or whole genome amplified sample.

  18. Discovery and validation of urine markers of acute pediatric appendicitis using high accuracy mass spectrometry

    Science.gov (United States)

    Kentsis, Alex; Lin, Yin Yin; Kurek, Kyle; Calicchio, Monica; Wang, Yan Yan; Monigatti, Flavio; Campagne, Fabien; Lee, Richard; Horwitz, Bruce; Steen, Hanno; Bachur, Richard

    2015-01-01

    Study Objective Molecular definition of disease has been changing all aspects of medical practice, from diagnosis and screening to understanding and treatment. Acute appendicitis is among many human conditions that are complicated by the heterogeneity of clinical presentation and shortage of diagnostic markers. Here, we sought to profile the urine of patients with appendicitis with the goal of identifying new diagnostic markers. Methods Candidate markers were identified from the urine of children with histologically proven appendicitis by using high accuracy mass spectrometry proteome profiling. These systemic and local markers were used to assess the probability of appendicitis in a blinded, prospective study of children being evaluated for acute abdominal pain in our emergency department. Tests of performance of the markers were evaluated against the pathologic diagnosis and histologic grade of appendicitis. Results Test performance of 57 identified candidate markers was studied in 67 patients, with median age of 11 years, 37% of whom had appendicitis. Several exhibited favorable diagnostic performance, including calgranulin A (S100-A8), α-1-acid glycoprotein 1 (orosomucoid), and leucine-rich α-2-glycoprotein (LRG), with the ROC AUC and values of 0.84 (95 % CI 0.72-0.95), 0.84 (0.72-0.95), and 0.97 (0.93-1.0), respectively. LRG was enriched in diseased appendices and its abundance correlated with severity of appendicitis. Conclusions High accuracy mass spectrometry urine proteome profiling allowed identification of diagnostic markers of acute appendicitis. Usage of LRG and other identified biomarkers may improve the diagnostic accuracy of clinical evaluations of appendicitis. PMID:19556024

  19. SpaceNav - A high accuracy navigation system for space applications

    Science.gov (United States)

    Evers, H.-H.

    The technology of the SpaceNav-system is based on research performed by the Institute of Flight Guidance and Control at the Technical University of Braunschweig, Germany. In 1989 this institute gave the worlds first public demonstration of a fully automatic landing of an aircraft, using inertial and satellite informations exclusively. The SpaceNav device components are: Acceleration-/Gyro Sensor Package; Global Positioning System (GPS) Receiver/optional more than one; Time Reference Unit; CPU; Telemetry (optional); and Differential GPS (DGPS) Receiver (optional). The coupling of GPS receivers with inertial sensors provides an extremely accurate navigation data set in real time applications even in phases with high dynamic conditions. The update rate of this navigation information is up to 100 Hz with the same accuracy in 3D-position, velocity, acceleration, attitude and time. SpaceNav is an integrated navigation system, which operates according to the principle of combining the longterm stability and accuracy of GPS, and the high level of dynamic precision of conventional inertial navigation system (INS) strapdown systems. The system's design allows other aiding sensors e.g. GLONASS satellite navigation system, distance measuring equipment (DME), altimeter (radar and/or barometric), flux valve etc. to be connected, in order to increase the redundancy of the system. The advantage of such an upgraded system is the availability of more sensor information than necessary for a navigation solution. The resulting redundancy in range measurement allows real-time detection and identification of sensor signals that are incompatible with the other information. As a result you get Receiver Autonomous Integrity Monitoring (RAIM) as described in 'A Multi-Sensor Approach to Assuring GPS Integrity', presented by Alison Brown in the March/April 1990 issue of 'GPS World'. In this paper the author presents information about the principles of the Satellite Navigation System GPS, and

  20. High-accuracy determination for optical indicatrix rotation in ferroelectric DTGS

    OpenAIRE

    O.S.Kushnir; O.A.Bevz; O.G.Vlokh

    2000-01-01

    Optical indicatrix rotation in deuterated ferroelectric triglycine sulphate is studied with the high-accuracy null-polarimetric technique. The behaviour of the effect in ferroelectric phase is referred to quadratic spontaneous electrooptics.

  1. High-accuracy interferometric measurements of flatness and parallelism of a step gauge

    CSIR Research Space (South Africa)

    Kruger, OA

    2001-01-01

    Full Text Available for the calibration of step gauges to a high accuracy. A system was also developed for interferometric measurements of the flatness and parallelism of gauge block faces for use in uncertainty calculations....

  2. High Accuracy Reference Network (HARN), Points generated from coordinates supplied by NGS, Published in 1993, MARIS.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This High Accuracy Reference Network (HARN) dataset, was produced all or in part from Field Survey/GPS information as of 1993. It is described as 'Points generated...

  3. Prioritizing spatial accuracy in high-resolution fMRI data using multivariate feature weight mapping

    Directory of Open Access Journals (Sweden)

    Johannes eStelzer

    2014-04-01

    Full Text Available Although ultra-high-field fMRI at field strengths of 7T or above provides substantial gains in BOLD contrast-to-noise ratio, when very high-resolution fMRI is required such gains are inevitably reduced. The improvement in sensitivity provided by multivariate analysis techniques, as compared with univariate methods, then becomes especially welcome. Information mapping approaches are commonly used, such as the searchlight technique, which take into account the spatially distributed patterns of activation in order to predict stimulus conditions. However, the popular searchlight decoding technique, in particular, has been found to be prone to spatial inaccuracies. For instance, the spatial extent of informative areas is generally exaggerated, and their spatial configuration is distorted. We propose the combination of a nonparametric and permutation-based statistical framework with linear classifiers. We term this new combined method Feature Weight Mapping (FWM. The main goal of the proposed method is to map the specific contribution of each voxel to the classification decision while including a correction for the multiple comparisons problem. Next, we compare this new method to the searchlight approach using a simulation and ultra-high-field 7T experimental data. We found that the searchlight method led to spatial inaccuracies that are especially noticeable in high-resolution fMRI data. In contrast, FWM was more spatially precise, revealing both informative anatomical structures as well as the direction by which voxels contribute to the classification. By maximizing the spatial accuracy of ultra-high-field fMRI results, global multivariate methods provide a substantial improvement for characterizing structure-function relationships.

  4. The Second—Order Imaginary Plane Method and Its Calculation Accuracy

    Institute of Scientific and Technical Information of China (English)

    DongPeng; ChenXiaodong; 等

    1997-01-01

    In this paper,the basic principles and mathematical process of the Second-order Imaginary Plane Method(IPM) for modeling the radiative haet transfer are analysed and proved in detail.Through the numerical computation for the real process of the radiative heat transfer using the Second-order IPM,the previous IPM(the first-order),the Analytic Method and the Zone Method,it was shown that the calculation accuracy of the Second-order IPM is much higher than that of the first-order IPM,and its demand to computer capacity and time consuming is much lower than that of of the Zone Method.It is verified that the method is more effective and has a higher accuracy for modeling radiative heat transfer in engineering.

  5. Finite-element solution of the coupled-channel Schrödinger equation using high-order accuracy approximations

    Science.gov (United States)

    Abrashkevich, A. G.; Abrashkevich, D. G.; Kaschiev, M. S.; Puzynin, I. V.

    1995-01-01

    The finite element method (FEM) is applied to solve the bound state (Sturm-Liouville) problem for systems of ordinary linear second-order differential equations. The convergence, accuracy and the range of applicability of the high-order FEM approximations (up to tenth order) are studied systematically on the basis of numerical experiments for a wide set of quantum-mechanical problems. The analytical and tabular forms of giving the coefficients of differential equations are considered. The Dirichlet and Neumann boundary conditions are discussed. It is shown that the use of the FEM high-order accuracy approximations considerably increases the accuracy of the FE solutions with substantial reduction of the requirements on the computational resources. The results of the FEM calculations for various quantum-mechanical problems dealing with different types of potentials used in atomic and molecular calculations (including the hydrogen atom in a homogeneous magnetic field) are shown to be well converged and highly accurate.

  6. Interlaboratory diagnostic accuracy of a Salmonella specific PCR-based method

    DEFF Research Database (Denmark)

    Malorny, B.; Hoorfar, Jeffrey; Hugas, M.;

    2003-01-01

    A collaborative study involving four European laboratories was conducted to investigate the diagnostic accuracy of a Salmonella specific PCR-based method, which was evaluated within the European FOOD-PCR project (http://www.pcr.dk). Each laboratory analysed by the PCR a set of independent obtaine...

  7. Assessing the Accuracy of Classwide Direct Observation Methods: Two Analyses Using Simulated and Naturalistic Data

    Science.gov (United States)

    Dart, Evan H.; Radley, Keith C.; Briesch, Amy M.; Furlow, Christopher M.; Cavell, Hannah J.; Briesch, Amy M.

    2016-01-01

    Two studies investigated the accuracy of eight different interval-based group observation methods that are commonly used to assess the effects of classwide interventions. In Study 1, a Microsoft Visual Basic program was created to simulate a large set of observational data. Binary data were randomly generated at the student level to represent…

  8. On the accuracy of the finite difference method for applications in beam propagating techniques

    NARCIS (Netherlands)

    Hoekstra, Hugo; Krijnen, Gijsbertus J.M.; Lambeck, Paul

    1992-01-01

    In this paper it is shown that the inaccuracy in the beam propagation method based on the finite difference scheme, introduced by the use of the slowly varying envelope approximation, can be overcome in an effective way. By the introduction of a perturbation expansion the accuracy can be improved as

  9. Evaluation of the accuracy of the Multiple Support Response Spectrum (MSRS) method

    DEFF Research Database (Denmark)

    Konakli, Katerina; Der Kiureghian, A.

    2012-01-01

    The MSRS rule is a response spectrum method for analysis of multiply supported structures subjected to spatially varying ground motions. This paper evaluates the accuracy of the MSRS rule by comparing MSRS estimates of mean peak responses with corresponding “exact” mean values obtained by time-hi...

  10. On the Teaching Methods to Balance Fluency & Accuracy for Chinese University English Learners

    Institute of Scientific and Technical Information of China (English)

    CHEN Jia

    2016-01-01

    By dividing English learners in Chinese university context into intermediate and advanced level learners, the essay ar-gues that fluency rather than accuracy is needed for most university students. It further discusses some suitable teaching methods in both contexts respectively to balance this pair of objective focus.

  11. ESTIMATE ACCURACY OF NONLINEAR COEFFICIENTS OF SQUEEZEFILM DAMPER USING STATE VARIABLE FILTER METHOD

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    The estimate model for a nonlinear system of squeeze-film damper (SFD) is described.The method of state variable filter (SVF) is used to estimate the coefficients of SFD.The factors which are critical to the estimate accuracy are discussed.

  12. Direct Georeferencing : a New Standard in Photogrammetry for High Accuracy Mapping

    Science.gov (United States)

    Rizaldy, A.; Firdaus, W.

    2012-07-01

    Direct georeferencing is a new method in photogrammetry, especially in the digital camera era. Theoretically, this method does not require ground control points (GCP) and the Aerial Triangulation (AT), to process aerial photography into ground coordinates. Compared with the old method, this method has three main advantages: faster data processing, simple workflow and less expensive project, at the same accuracy. Direct georeferencing using two devices, GPS and IMU. GPS recording the camera coordinates (X, Y, Z), and IMU recording the camera orientation (omega, phi, kappa). Both parameters merged into Exterior Orientation (EO) parameter. This parameters required for next steps in the photogrammetric projects, such as stereocompilation, DSM generation, orthorectification and mosaic. Accuracy of this method was tested on topographic map project in Medan, Indonesia. Large-format digital camera Ultracam X from Vexcel is used, while the GPS / IMU is IGI AeroControl. 19 Independent Check Point (ICP) were used to determine the accuracy. Horizontal accuracy is 0.356 meters and vertical accuracy is 0.483 meters. Data with this accuracy can be used for 1:2.500 map scale project.

  13. Design and calibration of a high-sensitivity and high-accuracy polarimeter based on liquid crystal variable retarders

    Science.gov (United States)

    Guo, Jing; Ren, De-Qing; Liu, Cheng-Chao; Zhu, Yong-Tian; Dou, Jiang-Pei; Zhang, Xi; Beck, Christian

    2017-01-01

    Polarimetry plays an important role in the measurement of solar magnetic fields. We developed a high-sensitivity and high-accuracy polarimeter (HHP) based on nematic liquid crystal variable retarders (LCVRs), which has a compact setup and no mechanical moving parts. The system design and calibration methods are discussed in detail. The azimuth error of the transmission axis of the polarizer as well as the fast axes of the two LCVRs and the quarter-wave plate were determined using dedicated procedures. Linearly and circularly polarized light were employed to evaluate the performance of the HHP. The experimental results indicate that a polarimetric sensitivity of better than \\[5.7 × {10 - 3}\\] can be achieved by using a single short-exposure image, while an accuracy on the order of 10‑5 can be reached by using a large number of short-exposure images. This makes the HHP a high-performance system that can be used with a ground-based solar telescope for high-precision solar magnetic field investigations.

  14. Data supporting the high-accuracy haplotype imputation using unphased genotype data as the references

    Directory of Open Access Journals (Sweden)

    Wenzhi Li

    2016-09-01

    Full Text Available The data presented in this article is related to the research article entitled “High-accuracy haplotype imputation using unphased genotype data as the references” which reports the unphased genotype data can be used as reference for haplotyping imputation [1]. This article reports different implementation generation pipeline, the results of performance comparison between different implementations (A, B, and C and between HiFi and three major imputation software tools. Our data showed that the performances of these three implementations are similar on accuracy, in which the accuracy of implementation-B is slightly but consistently higher than A and C. HiFi performed better on haplotype imputation accuracy and three other software performed slightly better on genotype imputation accuracy. These data may provide a strategy for choosing optimal phasing pipeline and software for different studies.

  15. Accuracy of imaging methods for detection of bone tissue invasion in patients with oral squamous cell carcinoma

    Science.gov (United States)

    Uribe, S; Rojas, LA; Rosas, CF

    2013-01-01

    The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854

  16. Accuracy Analysis of Geopotential Coefficients Recovered from In-situ Disturbing Potential by Energy Conservation Method

    Institute of Scientific and Technical Information of China (English)

    ZOU Xiancai; LI Jiancheng; LUO Jia; XU Xinyu

    2007-01-01

    The characteristics of the normal equation created in recovering the Earth gravity model (EGM) by least-squares(LS) adjustment from the in-situ disturbing potential is discussed in detail. It can be concluded that the normal equation only depends on the orbit, and the choice of a priori gravity model has no effect on the LS solution. Therefore, the accuracy of the recovered gravity model can be accurately simulated. Starting from this point, four sets of disturbing potential along the orbit with different level of noise were simulated and were used to recover the EGM. The results show that on the current accuracy level of the accelerometer calibration, the accuracy of the EGM is not sufficient to reflect the time variability of the Earth's gravity field, as the dynamic method revealed.

  17. A High-Performance Operational Amplifier for High-Speed High-Accuracy Switch-Capacitor Cells

    Institute of Scientific and Technical Information of China (English)

    Qi Fan; Ning Ning; Qi Yu; Da Chen

    2007-01-01

    A highspeed highaccuracy fully differenttial operational amplifier (opamp) is realized based on noMillercapacitor feedforward (NMCF) compensation scheme. In order to achieve a good phase margin, the NMCF compensation scheme uses the positive phase shift of lefthalfplane (LHP) zero caused by the feedforward path to counteract the negative phase shift of the nondominant pole. Compared to traditional Miller compensation method, the opamp obtains high gain and wide band synchronously without the polesplitting effect while saves significant chip area due to the absence of the Miller capacitor. Simulated by the 0.35 μm CMOS RF technology, the result shows that the openloop gain of the opamp is 118 dB with the unity gainbandwidth (UGBW)of 1 GHz, and the phase margin is 61°while the settling time is 5.8 ns when achieving 0.01% accuracy. The opamp is especially suitable for the frontend sample/hold (S/H)cell and the multiplying D/A converter(MDAC) module of the highspeed highresolution pipelined A/D converters(ADCs).

  18. A Method for Assessing the Accuracy of a Photogrammetry System for Precision Deployable Structures

    Science.gov (United States)

    Moore, Ashley

    2005-01-01

    The measurement techniques used to validate analytical models of large deployable structures are an integral Part of the technology development process and must be precise and accurate. Photogrammetry and videogrammetry are viable, accurate, and unobtrusive methods for measuring such large Structures. Photogrammetry uses Software to determine the three-dimensional position of a target using camera images. Videogrammetry is based on the same principle, except a series of timed images are analyzed. This work addresses the accuracy of a digital photogrammetry system used for measurement of large, deployable space structures at JPL. First, photogrammetry tests are performed on a precision space truss test article, and the images are processed using Photomodeler software. The accuracy of the Photomodeler results is determined through, comparison with measurements of the test article taken by an external testing group using the VSTARS photogrammetry system. These two measurements are then compared with Australis photogrammetry software that simulates a measurement test to predict its accuracy. The software is then used to study how particular factors, such as camera resolution and placement, affect the system accuracy to help design the setup for the videogrammetry system that will offer the highest level of accuracy for measurement of deploying structures.

  19. Diagnostic test accuracy: methods for systematic review and meta-analysis.

    Science.gov (United States)

    Campbell, Jared M; Klugar, Miloslav; Ding, Sandrine; Carmody, Dennis P; Hakonsen, Sasja J; Jadotte, Yuri T; White, Sarahlouise; Munn, Zachary

    2015-09-01

    Systematic reviews are carried out to provide an answer to a clinical question based on all available evidence (published and unpublished), to critically appraise the quality of studies, and account for and explain variations between the results of studies. The Joanna Briggs Institute specializes in providing methodological guidance for the conduct of systematic reviews and has developed methods and guidance for reviewers conducting systematic reviews of studies of diagnostic test accuracy. Diagnostic tests are used to identify the presence or absence of a condition for the purpose of developing an appropriate treatment plan. Owing to demands for improvements in speed, cost, ease of performance, patient safety, and accuracy, new diagnostic tests are continuously developed, and there are often several tests available for the diagnosis of a particular condition. In order to provide the evidence necessary for clinicians and other healthcare professionals to make informed decisions regarding the optimum test to use, primary studies need to be carried out on the accuracy of diagnostic tests and the results of these studies synthesized through systematic review. The Joanna Briggs Institute and its international collaboration have updated, revised, and developed new guidance for systematic reviews, including systematic reviews of diagnostic test accuracy. This methodological article summarizes that guidance and provides detailed advice on the effective conduct of systematic reviews of diagnostic test accuracy.

  20. A method for improving the accuracy of automatic indexing of Chinese-English mixed documents

    Institute of Scientific and Technical Information of China (English)

    Yan; ZHAO; Hui; SHI

    2012-01-01

    Purpose:The thrust of this paper is to present a method for improving the accuracy of automatic indexing of Chinese-English mixed documents.Design/methodology/approach:Based on the inherent characteristics of Chinese-English mixed texts and the cybernetics theory,we proposed an integrated control method for indexing documents.It consists of"feed-forward control","in-progress control"and"feed-back control",aiming at improving the accuracy of automatic indexing of Chinese-English mixed documents.An experiment was conducted to investigate the effect of our proposed method.Findings:This method distinguishes Chinese and English documents in grammatical structures and word formation rules.Through the implementation of this method in the three phases of automatic indexing for the Chinese-English mixed documents,the results were encouraging.The precision increased from 88.54%to 97.10%and recall improved from97.37%to 99.47%.Research limitations:The indexing method is relatively complicated and the whole indexing process requires substantial human intervention.Due to pattern matching based on a bruteforce(BF)approach,the indexing efficiency has been reduced to some extent.Practical implications:The research is of both theoretical significance and practical value in improving the accuracy of automatic indexing of multilingual documents(not confined to Chinese-English mixed documents).The proposed method will benefit not only the indexing of life science documents but also the indexing of documents in other subject areas.Originality/value:So far,few studies have been published about the method for increasing the accuracy of multilingual automatic indexing.This study will provide insights into the automatic indexing of multilingual documents,especially Chinese-English mixed documents.

  1. High Accuracy Extraction of Respiratory Sinus Arrhythmia with Statistical Processing using Normal Distribution

    Science.gov (United States)

    Numata, Takashi; Ogawa, Yutaro; Yoshida, Lui; Kotani, Kiyoshi; Jimbo, Yasuhiko

    The autonomic nervous system is important in maintaining homeostasis by mediating the opposing effects of the sympathetic and parasympathetic nervous activity on organs. Although it is known that the amplitude of RSA (Respiratory Sinus Arrhythmia) is an index of parasympathetic nervous activity, it is difficult to estimate that activity in real-time in everyday situations. It is partly caused by body motions and extrasystoles. Also, automatic recognition of the R-wave on electrocardiograms is required for real-time analysis of RSA amplitude, there is an unresolved problem of false recognition of the R-wave. In this paper, we propose a method to evaluate the amplitude of RSA accurately using statistical processing with probabilistic models. Then, we estimate parasympathetic nervous activity during body motion and isometric exercise to examine the validity of the method. As a result, using the proposed method, we demonstrate that the amplitude of RSA can be extracted with false recognition of the R-wave. In addition, an appropriate threshold for the estimate is one or five percent because waveforms of RSA amplitude do not follow the abrupt changes of the parasympathetic nervous activity evoked by isometric exercise with the threshold at ten percent. Furthermore, the method using normal distribution is found to be more appropriate than that of chi-square distribution for statistical processing. Therefore, we expect that the proposed method can evaluate parasympathetic nervous activity with high accuracy in everyday situations.

  2. Highly charged ions as a basis of optical atomic clockwork of exceptional accuracy.

    Science.gov (United States)

    Derevianko, Andrei; Dzuba, V A; Flambaum, V V

    2012-11-02

    We propose a novel class of atomic clocks based on highly charged ions. We consider highly forbidden laser-accessible transitions within the 4f(12) ground-state configurations of highly charged ions. Our evaluation of systematic effects demonstrates that these transitions may be used for building exceptionally accurate atomic clocks which may compete in accuracy with recently proposed nuclear clocks.

  3. High-accuracy extrapolated ab initio thermochemistry. II. Minor improvements to the protocol and a vital simplification

    Science.gov (United States)

    Bomble, Yannick J.; Vázquez, Juana; Kállay, Mihály; Michauk, Christine; Szalay, Péter G.; Császár, Attila G.; Gauss, Jürgen; Stanton, John F.

    2006-08-01

    The recently developed high-accuracy extrapolated ab initio thermochemistry method for theoretical thermochemistry, which is intimately related to other high-precision protocols such as the Weizmann-3 and focal-point approaches, is revisited. Some minor improvements in theoretical rigor are introduced which do not lead to any significant additional computational overhead, but are shown to have a negligible overall effect on the accuracy. In addition, the method is extended to completely treat electron correlation effects up to pentuple excitations. The use of an approximate treatment of quadruple and pentuple excitations is suggested; the former as a pragmatic approximation for standard cases and the latter when extremely high accuracy is required. For a test suite of molecules that have rather precisely known enthalpies of formation {as taken from the active thermochemical tables of Ruscic and co-workers [Lecture Notes in Computer Science, edited by M. Parashar (Springer, Berlin, 2002), Vol. 2536, pp. 25-38; J. Phys. Chem. A 108, 9979 (2004)]}, the largest deviations between theory and experiment are 0.52, -0.70, and 0.51kJmol-1 for the latter three methods, respectively. Some perspective is provided on this level of accuracy, and sources of remaining systematic deficiencies in the approaches are discussed.

  4. A Least Squares Collocation Method for Accuracy Improvement of Mobile LiDAR Systems

    Directory of Open Access Journals (Sweden)

    Qingzhou Mao

    2015-06-01

    Full Text Available In environments that are hostile to Global Navigation Satellites Systems (GNSS, the precision achieved by a mobile light detection and ranging (LiDAR system (MLS can deteriorate into the sub-meter or even the meter range due to errors in the positioning and orientation system (POS. This paper proposes a novel least squares collocation (LSC-based method to improve the accuracy of the MLS in these hostile environments. Through a thorough consideration of the characteristics of POS errors, the proposed LSC-based method effectively corrects these errors using LiDAR control points, thereby improving the accuracy of the MLS. This method is also applied to the calibration of misalignment between the laser scanner and the POS. Several datasets from different scenarios have been adopted in order to evaluate the effectiveness of the proposed method. The results from experiments indicate that this method would represent a significant improvement in terms of the accuracy of the MLS in environments that are essentially hostile to GNSS and is also effective regarding the calibration of misalignment.

  5. A High Accuracy Pedestrian Detection System Combining a Cascade AdaBoost Detector and Random Vector Functional-Link Net

    OpenAIRE

    Zhihui Wang; Sook Yoon; Shan Juan Xie; Yu Lu; Dong Sun Park

    2014-01-01

    In pedestrian detection methods, their high accuracy detection rates are always obtained at the cost of a large amount of false pedestrians. In order to overcome this problem, the authors propose an accurate pedestrian detection system based on two machine learning methods: cascade AdaBoost detector and random vector functional-link net. During the offline training phase, the parameters of a cascade AdaBoost detector and random vector functional-link net are trained by standard dataset. These...

  6. High accuracy and transferability of a neural network potential through charge equilibration for calcium fluoride

    Science.gov (United States)

    Faraji, Somayeh; Ghasemi, S. Alireza; Rostami, Samare; Rasoulkhani, Robabe; Schaefer, Bastian; Goedecker, Stefan; Amsler, Maximilian

    2017-03-01

    We investigate the accuracy and transferability of a recently developed high-dimensional neural network (NN) method for calcium fluoride, fitted to a database of ab initio density functional theory (DFT) calculations based on the Perdew-Burke-Ernzerhof (PBE) exchange correlation functional. We call the method charge equilibration via neural network technique (CENT). Although the fitting database contains only clusters (i.e., nonperiodic structures), the NN scheme accurately describes a variety of bulk properties. In contrast to other available empirical methods the CENT potential has a much simpler functional form, nevertheless it correctly reproduces the PBE energetics of various crystalline phases both at ambient and high pressure. Surface energies and structures as well as dynamical properties derived from phonon calculations are also in good agreement with PBE results. Overall, the difference between the values obtained by the CENT potential and the PBE reference values is less than or equal to the difference between the values of local density approximation (LDA) and Born-Mayer-Huggins (BMH) with those calculated by the PBE exchange correlation functional.

  7. A new method for the accuracy evaluation of a manufactured piece

    Science.gov (United States)

    Oniga, E. V.; Cardei, M.

    2015-11-01

    To evaluate the accuracy of a manufactured piece, it must be measured and compared with a reference model, namely the designed 3D model, based on geometrical elements. In this paper a new method for the precision evaluation of a manufactured piece is proposed, which implies the creation of the piece digital 3D model based on digital images and its transformation into a 3D mesh surface. The differences between the two models, the designed model and the new created one, are calculated using the Hausdorff distance. The aim of this research is to determine the differences between two 3D models, especially CAD models, with high precision, in a completely automated way. To obtain the results, a small piece has been photographed with a digital camera, that was calibrated using a 3D calibration object, a target consisting of a number of 42 points, 36 placed in the corners of 9 wood cubes with different heights and 6 of them placed at the middle of the distance between the cubes, on a board. This target was previously tested, the tests showing that using this calibration target instead of a 2D calibration grid, the precision of the final 3D model is improved with approximatly 50%. The 3D model of the manufactured piece was created using two methods. First, based on digital images, a point cloud was automatically generated and after the filtering process, the remaining points were interpolated, obtaining the piece 3D model as a mesh surface. Second, the piece 3D model was created using also the digital images, based on its characteristic points, resulting a CAD model, that was transformed into a mesh surface. Finally, the two 3D models were compared with the designed model, using the CloudCompare software, thus resulting the imperfections of the manufactured piece. The proposed method highlights the differences between the two models using a color palette, offering at the same time a global comparison.

  8. The effect of pattern overlap on the accuracy of high resolution electron backscatter diffraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Vivian, E-mail: v.tong13@imperial.ac.uk [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Jiang, Jun [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Wilkinson, Angus J. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Britton, T. Ben [Department of Materials, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom)

    2015-08-15

    High resolution, cross-correlation-based, electron backscatter diffraction (EBSD) measures the variation of elastic strains and lattice rotations from a reference state. Regions near grain boundaries are often of interest but overlap of patterns from the two grains could reduce accuracy of the cross-correlation analysis. To explore this concern, patterns from the interior of two grains have been mixed to simulate the interaction volume crossing a grain boundary so that the effect on the accuracy of the cross correlation results can be tested. It was found that the accuracy of HR-EBSD strain measurements performed in a FEG-SEM on zirconium remains good until the incident beam is less than 18 nm from a grain boundary. A simulated microstructure was used to measure how often pattern overlap occurs at any given EBSD step size, and a simple relation was found linking the probability of overlap with step size. - Highlights: • Pattern overlap occurs at grain boundaries and reduces HR-EBSD accuracy. • A test is devised to measure the accuracy of HR-EBSD in the presence of overlap. • High pass filters can sometimes, but not generally, improve HR-EBSD measurements. • Accuracy of HR-EBSD remains high until the reference pattern intensity is <72%. • 9% of points near a grain boundary will have significant error for 200nm step size in Zircaloy-4.

  9. [Diagnostic accuracy of the immersion high-frequency B-scan ultrasonography in chemical injured eyes].

    Science.gov (United States)

    Yang, Qinghua; Chen, Bing; Wang, Liqiang; Li, Zhaohui; Huang, Yifei

    2014-08-01

    To investigate the diagnostic accuracy of the immersion high-frequency B-scan ultrasonography, a noninvasive preoperative diagnosis method, in observing the anterior segment in chemical injured eyes. It was a retrospective study. Sixty-three ocular chemical injury patients (63 eyes), who accepted the keratoplasty or the artificial cornea transplant in PLA General Hospital from May 2011 to May 2013, were included in this study. All the injured eyes were examined by ultrasound bio-microscopy (UBM) and immersion high-frequency B-scan ultrasonography, respectively. The images were analyzed and the results were compared with the intraoperative findings. The observation of lens was the main parameter. All the 63 patients were examined with the UBM and the immersion high-frequency B-scan ultrasonography before the surgery. The findings of the cornea, anterior chamber angle, iris from UBM were consistent with those from the immersion high-frequency B-scan ultrasonography. As for the lens observation, in 32 eyes in which the lens were not detected by UBM, the lens were not detected in only 16 eyes, while 3 eyes with normal lens and 13 eyes with lens pacifications (1 eye with pyknotic lens) by immersion high-frequency B-scan ultrasonography. In 17 eyes in which the lens were found normal by UBM, there were only 14 eyes with normal lens and the rest 3 eyes' lens were found intumescent by immersion high-frequency B-scan ultrasonography. In 6 eyes in which lens were detected with suspicious by UBM, 2 eyes' lens were pyknotic and 4 eyes' lens were intumescent or clouded by immersion high-frequency B-scan ultrasonography. The findings of immersion high-frequency B-scan ultrasonography were highly consistent with the intraoperative findings. The lens could be observed accurately by immersion high-frequency B-scan ultrasonography in chemical injured eyes.

  10. Overdetermined Shooting Methods for Computing Standing Water Waves with Spectral Accuracy

    CERN Document Server

    Wilkening, Jon

    2012-01-01

    A high-performance shooting algorithm is developed to compute time-periodic solutions of the free-surface Euler equations with spectral accuracy in double and quadruple precision. The method is used to study resonance and its effect on standing water waves. We identify new nucleation mechanisms in which isolated large-amplitude solutions, and closed loops of such solutions, suddenly exist for depths below a critical threshold. We also study degenerate and secondary bifurcations related to Wilton's ripples in the traveling case, and explore the breakdown of self-similarity at the crests of extreme standing waves. In shallow water, we find that standing waves take the form of counter-propagating solitary waves that repeatedly collide quasi-elastically. In deep water with surface tension, we find that standing waves resemble counter-propagating depression waves. We also discuss existence and non-uniqueness of solutions, and smooth versus erratic dependence of Fourier modes on wave amplitude and fluid depth. In t...

  11. Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery

    Directory of Open Access Journals (Sweden)

    Loutfi-Krauss Britta

    2017-09-01

    Full Text Available For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany, which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA with 4.0mm resolution and to the Nonius (QUART, Germany, a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm. The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for

  12. Accuracy of Rhenium-188 SPECT/CT activity quantification for applications in radionuclide therapy using clinical reconstruction methods

    Science.gov (United States)

    Esquinas, Pedro L.; Uribe, Carlos F.; Gonzalez, M.; Rodríguez-Rodríguez, Cristina; Häfeli, Urs O.; Celler, Anna

    2017-08-01

    The main applications of 188Re in radionuclide therapies include trans-arterial liver radioembolization and palliation of painful bone-metastases. In order to optimize 188Re therapies, the accurate determination of radiation dose delivered to tumors and organs at risk is required. Single photon emission computed tomography (SPECT) can be used to perform such dosimetry calculations. However, the accuracy of dosimetry estimates strongly depends on the accuracy of activity quantification in 188Re images. In this study, we performed a series of phantom experiments aiming to investigate the accuracy of activity quantification for 188Re SPECT using high-energy and medium-energy collimators. Objects of different shapes and sizes were scanned in Air, non-radioactive water (Cold-water) and water with activity (Hot-water). The ordered subset expectation maximization algorithm with clinically available corrections (CT-based attenuation, triple-energy window (TEW) scatter and resolution recovery was used). For high activities, the dead-time corrections were applied. The accuracy of activity quantification was evaluated using the ratio of the reconstructed activity in each object to this object’s true activity. Each object’s activity was determined with three segmentation methods: a 1% fixed threshold (for cold background), a 40% fixed threshold and a CT-based segmentation. Additionally, the activity recovered in the entire phantom, as well as the average activity concentration of the phantom background were compared to their true values. Finally, Monte-Carlo simulations of a commercial γ -camera were performed to investigate the accuracy of the TEW method. Good quantification accuracy (errors  activity concentration and for objects in cold background segmented with a 1% threshold. However, the accuracy of activity quantification for objects segmented with 40% threshold or CT-based methods decreased (errors  >15%), mostly due to partial-volume effects. The Monte

  13. Development of an automatic calibration device for high-accuracy low temperature thermometers

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Based on the analysis and investigation of calibration systems for high-accuracy low temperature thermometers,a new facility for automatic calibration of high-accuracy low temperature thermometers was developed.Continuous calibration for multiple points can be made automatically with this device.According to the thermophysical characteristics of the constant-temperature block in this device,segmented Fuzzy-PID (proportional-integral-differential) algorithm was applied.The experimental results showed that the temperature fluctuation was smaller than ±0.005 K in 30 min.Therefore,this new device can fully meet the calibration requirement of high-precision low temperature thermometers.

  14. On the accuracy of Whitham's method. [for steady ideal gas flow past cones

    Science.gov (United States)

    Zahalak, G. I.; Myers, M. K.

    1974-01-01

    The steady flow of an ideal gas past a conical body is studied by the method of matched asymptotic expansions and by Whitham's method in order to assess the accuracy of the latter. It is found that while Whitham's method does not yield a correct asymptotic representation of the perturbation field to second order in regions where the flow ahead of the Mach cone of the apex is disturbed, it does correctly predict the changes of the second-order perturbation quantities across a shock (the first-order shock strength). The results of the analysis are illustrated by a special case of a flat, rectangular plate at incidence.

  15. Improving the accuracy of multiple integral evaluation by applying Romberg's method

    Science.gov (United States)

    Zhidkov, E. P.; Lobanov, Yu. Yu.; Rushai, V. D.

    2009-02-01

    Romberg’s method, which is used to improve the accuracy of one-dimensional integral evaluation, is extended to multiple integrals if they are evaluated using the product of composite quadrature formulas. Under certain conditions, the coefficients of the Romberg formula are independent of the integral’s multiplicity, which makes it possible to use a simple evaluation algorithm developed for one-dimensional integrals. As examples, integrals of multiplicity two to six are evaluated by Romberg’s method and the results are compared with other methods.

  16. Method of Improving the Navigation Accuracy of SINS by Continuous Rotation

    Institute of Scientific and Technical Information of China (English)

    YANG Yong; MIAO Ling-juan; SHEN Jun

    2005-01-01

    A method of improving the navigation accuracy of strapdown inertial navigation system (SINS) is studied. The particular technique discussed involves the continuous rotation of gyros and accelerometers cluster about the vertical axis of the vehicle. Then the errors of these sensors will have periodic variation corresponding to components along the body frame. Under this condition, the modulated sensor errors produce reduced system errors. Theoretical analysis based on a new coordinate system defined as sensing frame and test results are presented, and they indicate the method attenuates the navigation errors brought by the gyros' random constant drift and the accelerometer's bias and their white noise compared to the conventional method.

  17. Accuracy and Numerical Stabilty Analysis of Lattice Boltzmann Method with Multiple Relaxation Time for Incompressible Flows

    Science.gov (United States)

    Pradipto; Purqon, Acep

    2017-07-01

    Lattice Boltzmann Method (LBM) is the novel method for simulating fluid dynamics. Nowadays, the application of LBM ranges from the incompressible flow, flow in the porous medium, until microflows. The common collision model of LBM is the BGK with a constant single relaxation time τ. However, BGK suffers from numerical instabilities. These instabilities could be eliminated by implementing LBM with multiple relaxation time. Both of those scheme have implemented for incompressible 2 dimensions lid-driven cavity. The stability analysis has done by finding the maximum Reynolds number and velocity for converged simulations. The accuracy analysis is done by comparing the velocity profile with the benchmark results from Ghia, et al and calculating the net velocity flux. The tests concluded that LBM with MRT are more stable than BGK, and have a similar accuracy. The maximum Reynolds number that converges for BGK is 3200 and 7500 for MRT respectively.

  18. Report on achievements in fiscal 1999 on the project for research and development of an intellectual base creating and utilizing technology. Development of a screening test method with high accuracy for internal secretion disturbing substances; 1999 nendo chiteki kiban sosei riyo gijutsu kenkyu kaihatsu. Naibunpi kakuran busshitsu no koseido screening shiken hoho no kaihatsu oyobi data kiban seibi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This paper describes the achievements in fiscal 1999 on developing a screening test method with high accuracy for internal secretion disturbing substances. Development was made in cooperation with the OECD on the screening method that uses as a parameter whether a chemical substance has a hormone-like activity. For the womb breeding assay method to evaluate a feminine hormone-like activity, a reproducibility and comparison test was performed on womb breeding in immature rats administered with ethinylestradiol, the administration routes, and animals used (young and weak rats, and rats whose ovaries have been extracted). In order to evaluate a masculine hormone-like activity, the basic data were collected to develop the Hershberger method, and participation was made in the OECD verification tests. Discussions were given on comparison on castrated and non-castrated rats when 17 {alpha}-methyltestosterone was administered, the administration period of time and reproducibility when immature rats were used. The Hershberger method reactivity was discussed on rats relative to estrogen. In a toxicity test using 28-day repetitive administration, bisphenol A gave impacts on the kidney, the stomach and intestine tubes. (NEDO)

  19. [Assessment of overall spatial accuracy in image guided stereotactic body radiotherapy using a spine registration method].

    Science.gov (United States)

    Nakazawa, Hisato; Uchiyama, Yukio; Komori, Masataka; Hayashi, Naoki

    2014-06-01

    Stereotactic body radiotherapy (SBRT) for lung and liver tumors is always performed under image guidance, a technique used to confirm the accuracy of setup positioning by fusing planning digitally reconstructed radiographs with X-ray, fluoroscopic, or computed tomography (CT) images, using bony structures, tumor shadows, or metallic markers as landmarks. The Japanese SBRT guidelines state that bony spinal structures should be used as the main landmarks for patient setup. In this study, we used the Novalis system as a linear accelerator for SBRT of lung and liver tumors. The current study compared the differences between spine registration and target registration and calculated total spatial accuracy including setup uncertainty derived from our image registration results and the geometric uncertainty of the Novalis system. We were able to evaluate clearly whether overall spatial accuracy is achieved within a setup margin (SM) for planning target volume (PTV) in treatment planning. After being granted approval by the Hospital and University Ethics Committee, we retrospectively analyzed eleven patients with lung tumor and seven patients with liver tumor. The results showed the total spatial accuracy to be within a tolerable range for SM of treatment planning. We therefore regard our method to be suitable for image fusion involving 2-dimensional X-ray images during the treatment planning stage of SBRT for lung and liver tumors.

  20. K{sub 0}-INAA method accuracy using Zn as comparator

    Energy Technology Data Exchange (ETDEWEB)

    Bedregal, P., E-mail: pbedregal@ipen.gob.p [Instituto Peruano de Energia Nuclear (IPEN), Av. Canada 1470, Sn. Borja 1470, Lima 41 (Peru); Mendoza, P.; Ubillus, M. [Instituto Peruano de Energia Nuclear (IPEN), Av. Canada 1470, Sn. Borja 1470, Lima 41 (Peru); Montoya, E., E-mail: emontoya@ipen.gob.p [Instituto Peruano de Energia Nuclear (IPEN), Av. Canada 1470, Sn. Borja 1470, Lima 41 (Peru)

    2010-10-11

    An evaluation of the accuracy in the application of the k{sub 0}-INAA method using Zn foil as comparator is presented. A good agreement was found in the precision within analysts and between them, as well as in the assessment of trueness for most elements. The determination of important experimental parameters like gamma peak counting efficiency, {gamma}-{gamma} true coincidence, comparator preparation and quality assurance/quality control is also described and discussed.

  1. Measurement methods and accuracy analysis of Chang'E-5 Panoramic Camera installation parameters

    Science.gov (United States)

    Yan, Wei; Ren, Xin; Liu, Jianjun; Tan, Xu; Wang, Wenrui; Chen, Wangli; Zhang, Xiaoxia; Li, Chunlai

    2016-04-01

    Chang'E-5 (CE-5) is a lunar probe for the third phase of China Lunar Exploration Project (CLEP), whose main scientific objectives are to implement lunar surface sampling and to return the samples back to the Earth. To achieve these goals, investigation of lunar surface topography and geological structure within sampling area seems to be extremely important. The Panoramic Camera (PCAM) is one of the payloads mounted on CE-5 lander. It consists of two optical systems which installed on a camera rotating platform. Optical images of sampling area can be obtained by PCAM in the form of a two-dimensional image and a stereo images pair can be formed by left and right PCAM images. Then lunar terrain can be reconstructed based on photogrammetry. Installation parameters of PCAM with respect to CE-5 lander are critical for the calculation of exterior orientation elements (EO) of PCAM images, which is used for lunar terrain reconstruction. In this paper, types of PCAM installation parameters and coordinate systems involved are defined. Measurement methods combining camera images and optical coordinate observations are studied for this work. Then research contents such as observation program and specific solution methods of installation parameters are introduced. Parametric solution accuracy is analyzed according to observations obtained by PCAM scientifically validated experiment, which is used to test the authenticity of PCAM detection process, ground data processing methods, product quality and so on. Analysis results show that the accuracy of the installation parameters affects the positional accuracy of corresponding image points of PCAM stereo images within 1 pixel. So the measurement methods and parameter accuracy studied in this paper meet the needs of engineering and scientific applications. Keywords: Chang'E-5 Mission; Panoramic Camera; Installation Parameters; Total Station; Coordinate Conversion

  2. DEVELOPMENT OF A METHOD STATISTICAL ANALYSIS ACCURACY AND PROCESS STABILITY PRODUCTION OF EPOXY RESIN ED-20

    Directory of Open Access Journals (Sweden)

    N. V. Zhelninskaya

    2015-01-01

    Full Text Available Statistical methods play an important role in the objective evaluation of quantitative and qualitative characteristics of the process and are one of the most important elements of the quality assurance system production and total quality management process. To produce a quality product, one must know the real accuracy of existing equipment, to determine compliance with the accuracy of a selected technological process specified accuracy products, assess process stability. Most of the random events in life, particularly in manufacturing and scientific research, are characterized by the presence of a large number of random factors, is described by a normal distribution, which is the main in many practical studies. Modern statistical methods is quite difficult to grasp and wide practical use without in-depth mathematical training of all participants in the process. When we know the distribution of a random variable, you can get all the features of this batch of products, to determine the mean value and the variance. Using statistical control methods and quality control in the analysis of accuracy and stability of the technological process of production of epoxy resin ED20. Estimated numerical characteristics of the law of distribution of controlled parameters and determined the percentage of defects of the investigated object products. For sustainability assessment of manufacturing process of epoxy resin ED-20 selected Shewhart control charts, using quantitative data, maps of individual values of X and sliding scale R. Using Pareto charts identify the causes that affect low dynamic viscosity in the largest extent. For the analysis of low values of dynamic viscosity were the causes of defects using Ishikawa diagrams, which shows the most typical factors of the variability of the results of the process. To resolve the problem, it is recommended to modify the polymer composition of carbon fullerenes and to use the developed method for the production of

  3. Study on High Accuracy Topographic Mapping via UAV-based Images

    Science.gov (United States)

    Chi, Yun-Yao; Lee, Ya-Fen; Tsai, Shang-En

    2016-10-01

    Unmanned aerial vehicle (UAV) provides a promising tool for the acquisition of such multi-temporal aerial stereo photos and high-resolution digital surface models. Recently, the flight of UAVs operates with high degrees of autonomy by the global position system and onboard digit camera and computer. The UAV-based mapping can be obtained faster and cheaper, but its accuracy is anxious. This paper aims to identify the integration ability of high accuracy topographic map via the image of quad-rotors UAV and ground control points (GCPs). The living survey data is collected in the Errn river basins area in Tainan, Taiwan. The high accuracy UAV-based topographic in the study area is calibrated by the local coordinate of GCPs using the total station with the accuracy less than 1/2000. The comparison results show the accuracy of UAV-based topographic is accepted by overlapping. The results can be a reference for the practice works of mapping survey in earth.

  4. Predicting the accuracy of ligand overlay methods with Random Forest models.

    Science.gov (United States)

    Nandigam, Ravi K; Evans, David A; Erickson, Jon A; Kim, Sangtae; Sutherland, Jeffrey J

    2008-12-01

    The accuracy of binding mode prediction using standard molecular overlay methods (ROCS, FlexS, Phase, and FieldCompare) is studied. Previous work has shown that simple decision tree modeling can be used to improve accuracy by selection of the best overlay template. This concept is extended to the use of Random Forest (RF) modeling for template and algorithm selection. An extensive data set of 815 ligand-bound X-ray structures representing 5 gene families was used for generating ca. 70,000 overlays using four programs. RF models, trained using standard measures of ligand and protein similarity and Lipinski-related descriptors, are used for automatically selecting the reference ligand and overlay method maximizing the probability of reproducing the overlay deduced from X-ray structures (i.e., using rmsd overlay accuracy, and their use in template and method selection produces correct overlays in 57% of cases for 349 overlay ligands not used for training RF models. The inclusion in the models of protein sequence similarity enables the use of templates bound to related protein structures, yielding useful results even for proteins having no available X-ray structures.

  5. Improving the diagnostic accuracy of dysplastic and melanoma lesions using the decision template combination method.

    Science.gov (United States)

    Faal, Maryam; Miran Baygi, Mohammad Hossein; Kabir, Ehsanollah

    2013-02-01

    Melanoma is the most dangerous type of skin cancer, and early detection of suspicious lesions can decrease the mortality rate of this cancer. In this article, we present a multi-classifier system for improving the diagnostic accuracy of melanoma and dysplastic lesions based on the decision template combination rule. First, the lesion is differentiated from the surrounding healthy skin in an image. Next, shape, colour and texture features are extracted from the lesion image. Different subsets of these features are fed to three different classifiers: k-nearest neighbour (k-NN), support vector machine (SVM) and linear discriminant analysis (LDA). The decision template method is used to combine the outputs of these classifiers. The proposed method has been evaluated on a set of 436 dermatoscopic images of benign, dysplastic and melanoma lesions. The final classifier ensemble delivers a total classification accuracy of 80.46%, with 67.73% of dysplastic lesions correctly classified and 83.53% of melanoma lesions correctly classified. The results show that the proposed method significantly increases the diagnostic accuracy of dysplastic and melanoma lesions compared with a single classifier. The total classification rate is also improved. © 2012 John Wiley & Sons A/S.

  6. Rigorous Training of Dogs Leads to High Accuracy in Human Scent Matching-To-Sample Performance.

    Directory of Open Access Journals (Sweden)

    Sophie Marchal

    Full Text Available Human scent identification is based on a matching-to-sample task in which trained dogs are required to compare a scent sample collected from an object found at a crime scene to that of a suspect. Based on dogs' greater olfactory ability to detect and process odours, this method has been used in forensic investigations to identify the odour of a suspect at a crime scene. The excellent reliability and reproducibility of the method largely depend on rigor in dog training. The present study describes the various steps of training that lead to high sensitivity scores, with dogs matching samples with 90% efficiency when the complexity of the scents presented during the task in the sample is similar to that presented in the in lineups, and specificity reaching a ceiling, with no false alarms in human scent matching-to-sample tasks. This high level of accuracy ensures reliable results in judicial human scent identification tests. Also, our data should convince law enforcement authorities to use these results as official forensic evidence when dogs are trained appropriately.

  7. Spline-based high-accuracy piecewise-polynomial phase-to-sinusoid amplitude converters.

    Science.gov (United States)

    Petrinović, Davor; Brezović, Marko

    2011-04-01

    We propose a method for direct digital frequency synthesis (DDS) using a cubic spline piecewise-polynomial model for a phase-to-sinusoid amplitude converter (PSAC). This method offers maximum smoothness of the output signal. Closed-form expressions for the cubic polynomial coefficients are derived in the spectral domain and the performance analysis of the model is given in the time and frequency domains. We derive the closed-form performance bounds of such DDS using conventional metrics: rms and maximum absolute errors (MAE) and maximum spurious free dynamic range (SFDR) measured in the discrete time domain. The main advantages of the proposed PSAC are its simplicity, analytical tractability, and inherent numerical stability for high table resolutions. Detailed guidelines for a fixed-point implementation are given, based on the algebraic analysis of all quantization effects. The results are verified on 81 PSAC configurations with the output resolutions from 5 to 41 bits by using a bit-exact simulation. The VHDL implementation of a high-accuracy DDS based on the proposed PSAC with 28-bit input phase word and 32-bit output value achieves SFDR of its digital output signal between 180 and 207 dB, with a signal-to-noise ratio of 192 dB. Its implementation requires only one 18 kB block RAM and three 18-bit embedded multipliers in a typical field-programmable gate array (FPGA) device.

  8. Improved High Dynamic Range Image Reproduction Method

    Directory of Open Access Journals (Sweden)

    András Rövid

    2007-10-01

    Full Text Available High dynamic range (HDR of illumination may cause serious distortions andother problems in viewing and further processing of digital images. This paper describes anew algorithm for HDR image creation based on merging images taken with differentexposure time. There are many fields, in which HDR images can be used advantageously,with the help of them the accuracy, reliability and many other features of the certain imageprocessing methods can be improved.

  9. Accuracy, precision, usability, and cost of portable silver test methods for ceramic filter factories.

    Science.gov (United States)

    Meade, Rhiana D; Murray, Anna L; Mittelman, Anjuliee M; Rayner, Justine; Lantagne, Daniele S

    2017-02-01

    Locally manufactured ceramic water filters are one effective household drinking water treatment technology. During manufacturing, silver nanoparticles or silver nitrate are applied to prevent microbiological growth within the filter and increase bacterial removal efficacy. Currently, there is no recommendation for manufacturers to test silver concentrations of application solutions or filtered water. We identified six commercially available silver test strips, kits, and meters, and evaluated them by: (1) measuring in quintuplicate six samples from 100 to 1,000 mg/L (application range) and six samples from 0.0 to 1.0 mg/L (effluent range) of silver nanoparticles and silver nitrate to determine accuracy and precision; (2) conducting volunteer testing to assess ease-of-use; and (3) comparing costs. We found no method accurately detected silver nanoparticles, and accuracy ranged from 4 to 91% measurement error for silver nitrate samples. Most methods were precise, but only one method could test both application and effluent concentration ranges of silver nitrate. Volunteers considered test strip methods easiest. The cost for 100 tests ranged from 36 to 1,600 USD. We found no currently available method accurately and precisely measured both silver types at reasonable cost and ease-of-use, thus these methods are not recommended to manufacturers. We recommend development of field-appropriate methods that accurately and precisely measure silver nanoparticle and silver nitrate concentrations.

  10. Accuracy of the estimates of ammonia concentration in rumen fluid using different analytical methods

    Directory of Open Access Journals (Sweden)

    N.K.P. Souza

    2013-12-01

    Full Text Available The accuracy of two different methods in measuring the ammonia nitrogen (N-NH3 concentration in rumen fluid were evaluated: a catalyzed indophenol colorimetric reaction (CICR and the Kjeldahl distillation (KD. Five buffered standard solutions containing volatile fatty acids, true protein, and known ammonia concentrations (0, 3, 6, 12, and 24 N-NH3 mg/dL were used to simulate rumen fluid. Different ratios (10:1, 7.5:1, 5:1, 2.5:1, 1:1, 1:2.5, 1:5, 1:7.5, and 1:10 of a potassium hydroxide solution (KOH, 2 mol/L to standard solutions were evaluated by the KD method. The accuracy of each method was evaluated by adjusting a simple linear regression model of the estimated N-NH3 concentrations on the N-NH3 concentrations in the standard solutions. When the KD method was used, N-NH3 was observed to be released from the deamination of true protein (P0.05. The estimates of the N-NH3 concentration obtained by the CICR method were found to be accurate (P>0.05. After the accuracy evaluation, ninety-three samples of rumen fluid were evaluated by the CICR and KD methods (using the 5:1 ratio of KOH solution to rumen fluid sample, assuming that the CICR estimates would be accurate. The N-NH3 concentrations obtained by the two methods were observed to be different (P<0.05 but strongly correlated (r = 0.9701. Thus, it was concluded that the estimates obtained by the Kjeldahl distillation using a 5:1 ratio of KOH solution to rumen fluid sample can be adjusted to avoid biases. Furthermore, a model to adjust the N-NH3 concentration is suggested.

  11. Raman spectroscopic determination of the molecular constants of the hydrogen isotopologues with high accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Krasch, Bennet; Mirz, Sebastian; Groessle, Robin [Karlsruhe Institute of Technology KIT (Germany). Institute for Technical Physics (ITEP), Tritium Laboratory Karlsruhe (TLK); Collaboration: KATRIN-Collaboration

    2016-07-01

    The interest in the thermodynamic properties of gases as the chemical equilibrium is faced by the challenge of time-consuming and technical extensive experimental setups. One possible solution is the derivation of these properties from the molecular constants. The rotational and vibrational movement of diatomic molecules, as the hydrogen isotopologues, is described by the concept of the rotational anharmonic oscillator. The molecular constants are the free parameters of this concept. Molecular constants themselves can be determined by measuring the line position of rotational and/or rotational transitions e.g. with Raman spectroscopy for hydrogen as it has been done since several years. In this contribution a Raman method was development to measure the molecular constant of the hydrogen isotopologues with high accuracy to obtain reliable results. But not only the method was development but also a complete measurement uncertainty budget was set up. The uncertainty budget contains all possible sources for uncertainties from the measurement period or the analysis process as well the contribution of each single uncertainty. The method and the uncertainty budget were exemplary tested on Deuterium.

  12. Assessing the accuracy and stability of variable selection methods for random forest modeling in ecology.

    Science.gov (United States)

    Fox, Eric W; Hill, Ryan A; Leibowitz, Scott G; Olsen, Anthony R; Thornbrugh, Darren J; Weber, Marc H

    2017-07-01

    Random forest (RF) modeling has emerged as an important statistical learning method in ecology due to its exceptional predictive performance. However, for large and complex ecological data sets, there is limited guidance on variable selection methods for RF modeling. Typically, either a preselected set of predictor variables are used or stepwise procedures are employed which iteratively remove variables according to their importance measures. This paper investigates the application of variable selection methods to RF models for predicting probable biological stream condition. Our motivating data set consists of the good/poor condition of n = 1365 stream survey sites from the 2008/2009 National Rivers and Stream Assessment, and a large set (p = 212) of landscape features from the StreamCat data set as potential predictors. We compare two types of RF models: a full variable set model with all 212 predictors and a reduced variable set model selected using a backward elimination approach. We assess model accuracy using RF's internal out-of-bag estimate, and a cross-validation procedure with validation folds external to the variable selection process. We also assess the stability of the spatial predictions generated by the RF models to changes in the number of predictors and argue that model selection needs to consider both accuracy and stability. The results suggest that RF modeling is robust to the inclusion of many variables of moderate to low importance. We found no substantial improvement in cross-validated accuracy as a result of variable reduction. Moreover, the backward elimination procedure tended to select too few variables and exhibited numerous issues such as upwardly biased out-of-bag accuracy estimates and instabilities in the spatial predictions. We use simulations to further support and generalize results from the analysis of real data. A main purpose of this work is to elucidate issues of model selection bias and instability to ecologists interested in

  13. Very high-accuracy calibration of radiation pattern and gain of a near-field probe

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Nielsen, Jeppe Majlund; Breinbjerg, Olav

    2014-01-01

    In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission of the Europ......In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission...

  14. High accuracy solution of bi-directional wave propagation in continuum mechanics

    Science.gov (United States)

    Mulloth, Akhil; Sawant, Nilesh; Haider, Ijlal; Sharma, Nidhi; Sengupta, Tapan K.

    2015-10-01

    Solution of partial differential equations by numerical method is strongly affected due to numerical errors, which are caused mainly by deviation of numerical dispersion relation from the physical dispersion relation. To quantify and control such errors and obtain high accuracy solutions, we consider a class of problems which involve second derivative of unknowns with respect to time. Here, we analyse numerical metrics such as the numerical group velocity, numerical phase speed and the numerical amplification factor for different methods in solving the model bi-directional wave equation (BDWE). Such equations can be solved directly, for example, by Runge-Kutta-Nyström (RKN) method. Alternatively, the governing equation can be converted to a set of first order in time equations and then using four-stage fourth order Runge-Kutta (RK4) method for time integration. Spatial discretisation considered are the classical second and fourth order central difference schemes, along with Lele's central compact scheme for evaluating second derivatives. In another version, we have used Lele's scheme for evaluating first derivatives twice to obtain the second derivative. As BDWE represents non-dissipative, non-dispersive dynamics, we also consider the canonical problem of linearised rotating shallow water equation (LRSWE) in a new formulation involving second order derivative in time, which represents dispersive waves along with a stationary mode. The computations of LRSWE with RK4 and RKN methods for temporal discretisation and Lele's compact schemes for spatial discretisation are compared with computations performed with RK4 method for time discretisation and staggered compact scheme (SCS) for spatial discretisation by treating it as a set of three equations as reported in Rajpoot et al. (2012) [1].

  15. MRI-Based Computed Tomography Metal Artifact Correction Method for Improving Proton Range Calculation Accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Peter C. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Schreibmann, Eduard; Roper, Justin; Elder, Eric; Crocker, Ian [Department of Radiation Oncology, Winship Cancer Institute of Emory University, Atlanta, Georgia (United States); Fox, Tim [Varian Medical Systems, Palo Alto, California (United States); Zhu, X. Ronald [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Dong, Lei [Scripps Proton Therapy Center, San Diego, California (United States); Dhabaan, Anees, E-mail: anees.dhabaan@emory.edu [Department of Radiation Oncology, Winship Cancer Institute of Emory University, Atlanta, Georgia (United States)

    2015-03-15

    Purpose: Computed tomography (CT) artifacts can severely degrade dose calculation accuracy in proton therapy. Prompted by the recently increased popularity of magnetic resonance imaging (MRI) in the radiation therapy clinic, we developed an MRI-based CT artifact correction method for improving the accuracy of proton range calculations. Methods and Materials: The proposed method replaces corrupted CT data by mapping CT Hounsfield units (HU number) from a nearby artifact-free slice, using a coregistered MRI. MRI and CT volumetric images were registered with use of 3-dimensional (3D) deformable image registration (DIR). The registration was fine-tuned on a slice-by-slice basis by using 2D DIR. Based on the intensity of paired MRI pixel values and HU from an artifact-free slice, we performed a comprehensive analysis to predict the correct HU for the corrupted region. For a proof-of-concept validation, metal artifacts were simulated on a reference data set. Proton range was calculated using reference, artifactual, and corrected images to quantify the reduction in proton range error. The correction method was applied to 4 unique clinical cases. Results: The correction method resulted in substantial artifact reduction, both quantitatively and qualitatively. On respective simulated brain and head and neck CT images, the mean error was reduced from 495 and 370 HU to 108 and 92 HU after correction. Correspondingly, the absolute mean proton range errors of 2.4 cm and 1.7 cm were reduced to less than 2 mm in both cases. Conclusions: Our MRI-based CT artifact correction method can improve CT image quality and proton range calculation accuracy for patients with severe CT artifacts.

  16. Development of a method of ICP algorithm accuracy improvement during shaped profiles and surfaces control

    Directory of Open Access Journals (Sweden)

    V.A. Pechenin

    2014-10-01

    Full Text Available In this paper we propose a method of improvement of operating accuracy of iterative closest point algorithm used for metrology problems solving when determining a location deviation. Compressor blade profiles of a gas turbine engine (GTE were used as an object for application of the method of deviation determining. It is proposed to formulate the problem of the best alignment in the developed method as a multiobjective problem including criteria of minimum of squared distances, normal vectors differences and depth of camber differences at corresponding points of aligned profiles. Variants of resolving the task using an integral criterion including the above-mentioned were considered. Optimization problems were solved using a quasi- Newton method of sequential quadratic programming. The proposed new method of improvement of the registration algorithm based on geometric features showed greater accuracy in comparison with the discussed methods of optimization of a distance between fitting points, especially if a small quantity of measurement points on the profiles was used.

  17. Complex shape product tolerance and accuracy control method for virtual assembly

    Science.gov (United States)

    Ma, Huiping; Jin, Yuanqiang; Zhang, Xiaoguang; Zhou, Hai

    2015-02-01

    The simulation of virtual assembly process for engineering design lacks of accuracy in the software of three-dimension CAD at present. Product modeling technology with tolerance, assembly precision preanalysis technique and precision control method are developed. To solve the problem of lack of precision information transmission in CAD, tolerance mathematical model of Small Displacement Torsor (SDT) is presented, which can bring about technology transfer and establishment of digital control function for geometric elements from the definition, description, specification to the actual inspection and evaluation process. Current tolerance optimization design methods for complex shape product are proposed for optimization of machining technology, effective cost control and assembly quality of the products.

  18. The Accuracy of Diagnostic Methods for Diabetic Retinopathy: A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Vicente Martínez-Vizcaíno

    Full Text Available The objective of this study was to evaluate the accuracy of the recommended glycemic measures for diagnosing diabetic retinopathy.We systematically searched MEDLINE, EMBASE, the Cochrane Library, and the Web of Science databases from inception to July 2015 for observational studies comparing the diagnostic accuracy of glycated hemoglobin (HbA1c, fasting plasma glucose (FPG, and 2-hour plasma glucose (2h-PG. Random effects models for the diagnostic odds ratio (dOR value computed by Moses' constant for a linear model and 95% CIs were used to calculate the accuracy of the test. Hierarchical summary receiver operating characteristic curves (HSROC were used to summarize the overall test performance.Eleven published studies were included in the meta-analysis. The pooled dOR values for the diagnosis of retinopathy were 16.32 (95% CI 13.86-19.22 for HbA1c and 4.87 (95% CI 4.39-5.40 for FPG. The area under the HSROC was 0.837 (95% CI 0.781-0.892 for HbA1c and 0.735 (95% CI 0.657-0.813 for FPG. The 95% confidence region for the point that summarizes the overall test performance of the included studies occurs where the cut-offs ranged from 6.1% (43.2 mmol/mol to 7.8% (61.7 mmol/mol for HbA1c and from 7.8 to 9.3 mmol/L for FPG. In the four studies that provided information regarding 2h-PG, the pooled accuracy estimates for HbA1c were similar to those of 2h-PG; the overall performance for HbA1c was superior to that for FPG.The three recommended tests for the diagnosis of type 2 diabetes in nonpregnant adults showed sufficient accuracy for their use in clinical settings, although the overall accuracy for the diagnosis of retinopathy was similar for HbA1c and 2h-PG, which were both more accurate than for FPG. Due to the variability and inconveniences of the glucose level-based methods, HbA1c appears to be the most appropriate method for the diagnosis diabetic retinopathy.

  19. Comparative adaptation accuracy of acrylic denture bases evaluated by two different methods.

    Science.gov (United States)

    Lee, Chung-Jae; Bok, Sung-Bem; Bae, Ji-Young; Lee, Hae-Hyoung

    2010-08-01

    This study examined the adaptation accuracy of acrylic denture base processed using fluid-resin (PERform), injection-moldings (SR-Ivocap, Success, Mak Press), and two compression-molding techniques. The adaptation accuracy was measured primarily by the posterior border gaps at the mid-palatal area using a microscope and subsequently by weighing of the weight of the impression material between the denture base and master cast using hand-mixed and automixed silicone. The correlation between the data measured using these two test methods was examined. The PERform and Mak Press produced significantly smaller maximum palatal gap dimensions than the other groups (psilicone material than the other groups (psilicone impression materials was affected by either the material or mixing variables.

  20. [Study on high accuracy detection of multi-component gas in oil-immerse power transformer].

    Science.gov (United States)

    Fan, Jie; Chen, Xiao; Huang, Qi-Feng; Zhou, Yu; Chen, Gang

    2013-12-01

    In order to solve the problem of low accuracy and mutual interference in multi-component gas detection, a kind of multi-component gas detection network with high accuracy was designed. A semiconductor laser with narrow bandwidth was utilized as light source and a novel long-path gas cell was also used in this system. By taking the single sine signal to modulate the spectrum of laser and using space division multiplexing (SDM) and time division multiplexing (TDM) technique, the detection of multi-component gas was achieved. The experiments indicate that the linearity relevance coefficient is 0. 99 and the measurement relative error is less than 4%. The system dynamic response time is less than 15 s, by filling a volume of multi-component gas into the gas cell gradually. The system has advantages of high accuracy and quick response, which can be used in the fault gas on-line monitoring for power transformers in real time.

  1. The Leech method for diagnosing constipation: intra- and interobserver variability and accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Lorijn, Fleur de; Voskuijl, Wieger P.; Taminiau, Jan A.; Benninga, Marc A. [Emma Children' s Hospital, Department of Paediatric Gastroenterology and Nutrition, Amsterdam (Netherlands); Rijn, Rick R. van; Henneman, Onno D.F. [Academic Medical Centre, Department of Radiology, Amsterdam (Netherlands); Heijmans, Jarom [Emma Children' s Hospital, Department of Paediatric Gastroenterology and Nutrition, Amsterdam (Netherlands); Academic Medical Centre, Department of Radiology, Amsterdam (Netherlands); Reitsma, Johannes B. [Academic Medical Centre, Department of Clinical Epidemiology and Biostatistics, Amsterdam (Netherlands)

    2006-01-01

    The data concerning the value of a plain abdominal radiograph in childhood constipation are inconsistent. Recently, positive results have been reported of a new radiographic scoring system, ''the Leech method'', for assessing faecal loading. To assess intra- and interobserver variability and determine diagnostic accuracy of the Leech method in identifying children with functional constipation (FC). A total of 89 children (median age 9.8 years) with functional gastrointestinal disorders were included in the study. Based on clinical parameters, 52 fulfilled the criteria for FC, six fulfilled the criteria for functional abdominal pain (FAP), and 31 for functional non-retentive faecal incontinence (FNRFI); the latter two groups provided the controls. To assess intra- and interobserver variability of the Leech method three scorers scored the same abdominal radiograph twice. A Leech score of 9 or more was considered as suggestive of constipation. ROC analysis was used to determine the diagnostic accuracy of the Leech method in separating patients with FC from control patients. Significant intraobserver variability was found between two scorers (P=0.005 and P<0.0001), whereas there was no systematic difference between the two scores of the other scorer (P=0.89). The scores between scorers differed systematically and displayed large variability. The area under the ROC curve was 0.68 (95% CI 0.58-0.80), indicating poor diagnostic accuracy. The Leech scoring method for assessing faecal loading on a plain abdominal radiograph is of limited value in the diagnosis of FC in children. (orig.)

  2. Determining Accuracy of Thermal Dissipation Methods-based Sap Flux in Japanese Cedar Trees

    Science.gov (United States)

    Su, Man-Ping; Shinohara, Yoshinori; Laplace, Sophie; Lin, Song-Jin; Kume, Tomonori

    2017-04-01

    Thermal dissipation method, one kind of sap flux measurement method that can estimate individual tree transpiration, have been widely used because of its low cost and uncomplicated operation. Although thermal dissipation method is widespread, the accuracy of this method is doubted recently because some tree species materials in previous studies were not suitable for its empirical formula from Granier due to difference of wood characteristics. In Taiwan, Cryptomeria japonica (Japanese cedar) is one of the dominant species in mountainous area, quantifying the transpiration of Japanese cedar trees is indispensable to understand water cycling there. However, no one have tested the accuracy of thermal dissipation methods-based sap flux for Japanese cedar trees in Taiwan. Thus, in this study we conducted calibration experiment using twelve Japanese cedar stem segments from six trees to investigate the accuracy of thermal dissipation methods-based sap flux in Japanese cedar trees in Taiwan. By pumping water from segment bottom to top and inserting probes into segments to collect data simultaneously, we compared sap flux densities calculated from real water uptakes (Fd_actual) and empirical formula (Fd_Granier). Exact sapwood area and sapwood depth of each sample were obtained from dying segment with safranin stain solution. Our results showed that Fd_Granier underestimated 39 % of Fd_actual across sap flux densities ranging from 10 to 150 (cm3m-2s-1); while applying sapwood depth corrected formula from Clearwater, Fd_Granier became accurately that only underestimated 0.01 % of Fd_actual. However, when sap flux densities ranging from 10 to 50 (cm3m-2s-1)which is similar with the field data of Japanese cedar trees in a mountainous area of Taiwan, Fd_Granier underestimated 51 % of Fd_actual, and underestimated 26 % with applying Clearwater sapwood depth corrected formula. These results suggested sapwood depth significantly impacted on the accuracy of thermal dissipation

  3. Improved photomask accuracy with a high-productivity DUV laser pattern generator

    Science.gov (United States)

    Öström, Thomas; Måhlén, Jonas; Karawajczyk, Andrzej; Rosling, Mats; Carlqvist, Per; Askebjer, Per; Karlin, Tord; Sallander, Jesper; Österberg, Anders

    2006-10-01

    A strategy for sub-100 nm technology nodes is to maximize the use of high-speed deep-UV laser pattern generators, reserving e-beam tools for the most critical photomask layers. With a 248 nm excimer laser and 0.82 NA projection optics, the Sigma7500 increases the application space of laser pattern generators. A programmable spatial light modulator (SLM) is imaged with partially coherent optics to compose the photomask pattern. Image profiles are enhanced with phase shifting in the pattern generator, and features below 200 nm are reliably printed. The Sigma7500 extends the SLM-based architecture with improvements to CD uniformity and placement accuracy, resulting from an error budget-based methodology. Among these improvements is a stiffer focus stage design with digital servos, resulting in improved focus stability. Tighter climate controls and improved dose control reduce drift during mask patterning. As a result, global composite CD uniformity below 5 nm (3σ) has been demonstrated, with placement accuracy below 10 nm (3σ) across the mask. Self-calibration methods are used to optimize and monitor system performance, reducing the need to print test plates. The SLM calibration camera views programmed test patterns, making it possible to evaluate image metrics such as CD uniformity and line edge roughness. The camera is also used to characterize image placement over the optical field. A feature called ProcessEqualizer TM has been developed to correct long-range CD errors arising from process effects on production photomasks. Mask data is sized in real time to compensate for pattern-dependent errors related to local pattern density, as well as for systematic pattern-independent errors such as radial CD signatures. Corrections are made in the pixel domain in the advanced adjustments processor, which also performs global biasing, stamp distortion compensation, and corner enhancement. In the Sigma7500, the mask pattern is imaged with full edge addressability in each

  4. Analysis of Accuracy of a High-speed Mobile Platform Control System

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The efficient manufacture technique involves a high-speed control of platform mobile system. A linear acutor is presented in this paper. The linear acutor is constructed as a linear stepper motor. However, to sustain both high accuracy and high speed for the position and speed control, A single-stack computer system is constructed and a special control algorithm is prescribed to controled the linear actuator continuously. In this paper, the nonlinear errors resulted from the magnetic saturation and the h...

  5. An improved multivariate analytical method to assess the accuracy of acoustic sediment classification maps.

    Science.gov (United States)

    Biondo, M.; Bartholomä, A.

    2014-12-01

    High resolution hydro acoustic methods have been successfully employed for the detailed classification of sedimentary habitats. The fine-scale mapping of very heterogeneous, patchy sedimentary facies, and the compound effect of multiple non-linear physical processes on the acoustic signal, cause the classification of backscatter images to be subject to a great level of uncertainty. Standard procedures for assessing the accuracy of acoustic classification maps are not yet established. This study applies different statistical techniques to automated classified acoustic images with the aim of i) quantifying the ability of backscatter to resolve grain size distributions ii) understanding complex patterns influenced by factors other than grain size variations iii) designing innovative repeatable statistical procedures to spatially assess classification uncertainties. A high-frequency (450 kHz) sidescan sonar survey, carried out in the year 2012 in the shallow upper-mesotidal inlet the Jade Bay (German North Sea), allowed to map 100 km2 of surficial sediment with a resolution and coverage never acquired before in the area. The backscatter mosaic was ground-truthed using a large dataset of sediment grab sample information (2009-2011). Multivariate procedures were employed for modelling the relationship between acoustic descriptors and granulometric variables in order to evaluate the correctness of acoustic classes allocation and sediment group separation. Complex patterns in the acoustic signal appeared to be controlled by the combined effect of surface roughness, sorting and mean grain size variations. The area is dominated by silt and fine sand in very mixed compositions; in this fine grained matrix, percentages of gravel resulted to be the prevailing factor affecting backscatter variability. In the absence of coarse material, sorting mostly affected the ability to detect gradual but significant changes in seabed types. Misclassification due to temporal discrepancies

  6. Evaluation of a finite-element reciprocity method for epileptic EEG source localization: Accuracy, computational complexity and noise robustness

    DEFF Research Database (Denmark)

    Shirvany, Yazdan; Rubæk, Tonny; Edelvik, Fredrik

    2013-01-01

    The aim of this paper is to evaluate the performance of an EEG source localization method that combines a finite element method (FEM) and the reciprocity theorem.The reciprocity method is applied to solve the forward problem in a four-layer spherical head model for a large number of test dipoles...... noise and electrode misplacement.The results show approximately 3% relative error between numerically calculated potentials done by the reciprocity theorem and the analytical solutions. When adding EEG noise with SNR between 5 and 10, the mean localization error is approximately 4.3 mm. For the case...... with 10 mm electrode misplacement the localization error is 4.8 mm. The reciprocity EEG source localization speeds up the solution of the inverse problem with more than three orders of magnitude compared to the state-of-the-art methods.The reciprocity method has high accuracy for modeling the dipole...

  7. Higher accuracy analytical approximations to a nonlinear oscillator with discontinuity by He's homotopy perturbation method

    Energy Technology Data Exchange (ETDEWEB)

    Belendez, A. [Departamento de Fisica, Ingenieria de Sistemas y Teoria de la Senal, Universidad de Alicante, Apartado 99, E-03080 Alicante (Spain)], E-mail: a.belendez@ua.es; Hernandez, A.; Belendez, T.; Neipp, C.; Marquez, A. [Departamento de Fisica, Ingenieria de Sistemas y Teoria de la Senal, Universidad de Alicante, Apartado 99, E-03080 Alicante (Spain)

    2008-03-17

    He's homotopy perturbation method is used to calculate higher-order approximate periodic solutions of a nonlinear oscillator with discontinuity for which the elastic force term is proportional to sgn(x). We find He's homotopy perturbation method works very well for the whole range of initial amplitudes, and the excellent agreement of the approximate frequencies and periodic solutions with the exact ones has been demonstrated and discussed. Only one iteration leads to high accuracy of the solutions with a maximal relative error for the approximate period of less than 1.56% for all values of oscillation amplitude, while this relative error is 0.30% for the second iteration and as low as 0.057% when the third-order approximation is considered. Comparison of the result obtained using this method with those obtained by different harmonic balance methods reveals that He's homotopy perturbation method is very effective and convenient.

  8. [Analysis on the accuracy of simple selection method of Fengshi (GB 31)].

    Science.gov (United States)

    Li, Zhixing; Zhang, Haihua; Li, Suhe

    2015-12-01

    To explore the accuracy of simple selection method of Fengshi (GB 31). Through the study of the ancient and modern data,the analysis and integration of the acupuncture books,the comparison of the locations of Fengshi (GB 31) by doctors from all dynasties and the integration of modern anatomia, the modern simple selection method of Fengshi (GB 31) is definite, which is the same as the traditional way. It is believed that the simple selec tion method is in accord with the human-oriented thought of TCM. Treatment by acupoints should be based on the emerging nature and the individual difference of patients. Also, it is proposed that Fengshi (GB 31) should be located through the integration between the simple method and body surface anatomical mark.

  9. Multivariate regional frequency analysis: Two new methods to increase the accuracy of measures

    Science.gov (United States)

    Abdi, Amin; Hassanzadeh, Yousef; Talatahari, Siamak; Fakheri-Fard, Ahmad; Mirabbasi, Rasoul; Ouarda, Taha B. M. J.

    2017-09-01

    The accurate detection of discordant sites in a heterogeneous region and the estimation of the regional parameters of a statistical distribution are two important issues in multivariate regional frequency analysis. In this study, two new methods are proposed for increasing the accuracy of the multivariate L-moment approach. The first one, the optimization-based method (OBM) is utilized to estimate the best distribution parameters. The second one is the rank-based method (RBM), which is used in the robust discordancy measure for identifying discordant sites. In order to assess the performance of the proposed approaches on the heterogeneity measure, real and simulated regions of drought characteristics are considered. The results confirm the usefulness of the new methods in comparison with some well-established techniques.

  10. A sampling method for estimating the accuracy of predicted breeding values in genetic evaluation

    Directory of Open Access Journals (Sweden)

    Laloë Denis

    2001-09-01

    Full Text Available Abstract A sampling-based method for estimating the accuracy of estimated breeding values using an animal model is presented. Empirical variances of true and estimated breeding values were estimated from a simulated n-sample. The method was validated using a small data set from the Parthenaise breed with the estimated coefficient of determination converging to the true values. It was applied to the French Salers data file used for the 2000 on-farm evaluation (IBOVAL of muscle development score. A drawback of the method is its computational demand. Consequently, convergence can not be achieved in a reasonable time for very large data files. Two advantages of the method are that a it is applicable to any model (animal, sire, multivariate, maternal effects... and b it supplies off-diagonal coefficients of the inverse of the mixed model equations and can therefore be the basis of connectedness studies.

  11. High-accuracy C-14 measurements for atmospheric CO2 samples by AMS

    NARCIS (Netherlands)

    Meijer, H.A.J.; Pertuisot, M.H.; van der Plicht, J.

    2006-01-01

    In this paper, we investigate how to achieve high-accuracy radiocarbon measurements by accelerator mass spectrometry (ANIS) and present measurement series (performed on archived CO2) of (CO2)-C-14 between 1985 and 1991 for Point Barrow (Alaska) and the South Pole. We report in detail the measurement

  12. Further results on the operation of high-accuracy drift chambers

    NARCIS (Netherlands)

    Breskin, A.; Charpak, G.; Gabioud, B.; Sauli, F.; Trautner, N.

    Optimization of the working parameters in the drift chambers with adjustable electric fields permits stable operation and high accuracies. Full saturation of the drift velocity leads to remarkable improvements, namely a very linear space-time correlation for perpendicular tracks, and simple

  13. From journal to headline: the accuracy of climate science news in Danish high quality newspapers

    DEFF Research Database (Denmark)

    Vestergård, Gunver Lystbæk

    2011-01-01

    analysis to examine the accuracy of Danish high quality newspapers in quoting scientific publications from 1997 to 2009. Out of 88 articles, 46 contained inaccuracies though the majority was found to be insignificant and random. The study concludes that Danish broadsheet newspapers are ‘moderately...

  14. A 1-V 15 μW High-Accuracy Temperature Switch

    NARCIS (Netherlands)

    Schinkel, D.; Boer, de R.P.; Annema, A.J.; Tuijl, van A.J.M.

    2004-01-01

    A CMOS temperature switch with uncalibrated high accuracy is presented. The circuit is based on the classical CMOS bandgap reference structure, using parasitic PNPs and a PTAT multiplier. The circuit was designed in a standard digital 0.18 m CMOS process. The temperature switch has an in-designed hy

  15. From journal to headline: the accuracy of climate science news in Danish high quality newspapers

    DEFF Research Database (Denmark)

    Vestergård, Gunver Lystbæk

    2011-01-01

    analysis to examine the accuracy of Danish high quality newspapers in quoting scientific publications from 1997 to 2009. Out of 88 articles, 46 contained inaccuracies though the majority was found to be insignificant and random. The study concludes that Danish broadsheet newspapers are ‘moderately...

  16. Novel Resistance Measurement Method: Analysis of Accuracy and Thermal Dependence with Applications in Fiber Materials

    Directory of Open Access Journals (Sweden)

    Silvia Casans

    2016-12-01

    Full Text Available Material resistance is important since different physicochemical properties can be extracted from it. This work describes a novel resistance measurement method valid for a wide range of resistance values up to 100 GΩ at a low powered, small sized, digitally controlled and wireless communicated device. The analog and digital circuits of the design are described, analysing the main error sources affecting the accuracy. Accuracy and extended uncertainty are obtained for a pattern decade box, showing a maximum of 1 % accuracy for temperatures below 30 ∘ C in the range from 1 MΩ to 100 GΩ. Thermal analysis showed stability up to 50 ∘ C for values below 10 GΩ and systematic deviations for higher values. Power supply V i applied to the measurement probes is also analysed, showing no differences in case of the pattern decade box, except for resistance values above 10 GΩ and temperatures above 35 ∘ C. To evaluate the circuit behaviour under fiber materials, an 11-day drying process in timber from four species (Oregon pine-Pseudotsuga menziesii, cedar-Cedrus atlantica, ash-Fraxinus excelsior, chestnut-Castanea sativa was monitored. Results show that the circuit, as expected, provides different resistance values (they need individual conversion curves for different species and the same ambient conditions. Additionally, it was found that, contrary to the decade box analysis, V i affects the resistance value due to material properties. In summary, the proposed circuit is able to accurately measure material resistance that can be further related to material properties.

  17. Novel Resistance Measurement Method: Analysis of Accuracy and Thermal Dependence with Applications in Fiber Materials.

    Science.gov (United States)

    Casans, Silvia; Rosado-Muñoz, Alfredo; Iakymchuk, Taras

    2016-12-14

    Material resistance is important since different physicochemical properties can be extracted from it. This work describes a novel resistance measurement method valid for a wide range of resistance values up to 100 GΩ at a low powered, small sized, digitally controlled and wireless communicated device. The analog and digital circuits of the design are described, analysing the main error sources affecting the accuracy. Accuracy and extended uncertainty are obtained for a pattern decade box, showing a maximum of 1 % accuracy for temperatures below 30 ∘ C in the range from 1 MΩ to 100 GΩ. Thermal analysis showed stability up to 50 ∘ C for values below 10 GΩ and systematic deviations for higher values. Power supply V i applied to the measurement probes is also analysed, showing no differences in case of the pattern decade box, except for resistance values above 10 GΩ and temperatures above 35 ∘ C. To evaluate the circuit behaviour under fiber materials, an 11-day drying process in timber from four species (Oregon pine-Pseudotsuga menziesii, cedar-Cedrus atlantica, ash-Fraxinus excelsior, chestnut-Castanea sativa) was monitored. Results show that the circuit, as expected, provides different resistance values (they need individual conversion curves) for different species and the same ambient conditions. Additionally, it was found that, contrary to the decade box analysis, V i affects the resistance value due to material properties. In summary, the proposed circuit is able to accurately measure material resistance that can be further related to material properties.

  18. Surgical accuracy in high tibial osteotomy: coronal equivalence of computer navigation and gap measurement.

    Science.gov (United States)

    Schröter, S; Ihle, C; Elson, D W; Döbele, S; Stöckle, U; Ateschrang, A

    2016-11-01

    Medial opening wedge high tibial osteotomy (MOW HTO) is now a successful operation with a range of indications, requiring an individualised approach to the choice of intended correction. This manuscript introduces the concept of surgical accuracy as the absolute deviation of the achieved correction from the intended correction, where small values represent greater accuracy. Surgical accuracy is compared in a randomised controlled trial (RCT) between gap measurement and computer navigation groups. This was a prospective RCT conducted over 3 years of 120 consecutive patients with varus malalignment and medial compartment osteoarthritis, who underwent MOW HTO. All procedures were planned with digital software. Patients were randomly assigned into gap measurement or computer navigation groups. Coronal plane alignment was judged using the mechanical tibiofemoral angle (mTFA), before and after surgery. Absolute (positive) values were calculated for surgical accuracy in each individual case. There was no significant difference in the mean intended correction between groups. The achieved mTFA revealed a small under-correction in both groups. This was attributed to a failure to account for saw blade thickness (gap measurement) and over-compensation for weight bearing (computer navigation). Surgical accuracy was 1.7° ± 1.2° (gap measurement) compared to 2.1° ± 1.4° (computer navigation) without statistical significance. The difference in tibial slope increases of 2.7° ± 3.9° (gap measurement) and 2.1° ± 3.9° (computer navigation) had statistical significance (P osteotomy for individual cases. This work is clinically relevant because coronal surgical accuracy was not superior in either group. Therefore, the increased expense and surgical time associated with navigated MOW HTO is not supported, because meticulously conducted gap measurement yields equivalent surgical accuracy. I.

  19. Functional knowledge transfer for high-accuracy prediction of under-studied biological processes.

    Directory of Open Access Journals (Sweden)

    Christopher Y Park

    Full Text Available A key challenge in genetics is identifying the functional roles of genes in pathways. Numerous functional genomics techniques (e.g. machine learning that predict protein function have been developed to address this question. These methods generally build from existing annotations of genes to pathways and thus are often unable to identify additional genes participating in processes that are not already well studied. Many of these processes are well studied in some organism, but not necessarily in an investigator's organism of interest. Sequence-based search methods (e.g. BLAST have been used to transfer such annotation information between organisms. We demonstrate that functional genomics can complement traditional sequence similarity to improve the transfer of gene annotations between organisms. Our method transfers annotations only when functionally appropriate as determined by genomic data and can be used with any prediction algorithm to combine transferred gene function knowledge with organism-specific high-throughput data to enable accurate function prediction. We show that diverse state-of-art machine learning algorithms leveraging functional knowledge transfer (FKT dramatically improve their accuracy in predicting gene-pathway membership, particularly for processes with little experimental knowledge in an organism. We also show that our method compares favorably to annotation transfer by sequence similarity. Next, we deploy FKT with state-of-the-art SVM classifier to predict novel genes to 11,000 biological processes across six diverse organisms and expand the coverage of accurate function predictions to processes that are often ignored because of a dearth of annotated genes in an organism. Finally, we perform in vivo experimental investigation in Danio rerio and confirm the regulatory role of our top predicted novel gene, wnt5b, in leftward cell migration during heart development. FKT is immediately applicable to many bioinformatics

  20. Accuracy verification of a simple local three-dimensional displacement measurement method of DIC with two images coordinates

    Indian Academy of Sciences (India)

    MING-HSIANG SHIH; SHIH-HENG TUNG; HAN-WEI HSIAO; WEN-PEI SUNG

    2016-04-01

    There are two methods applied for three-dimensional digital image correlation method to measure three-dimensional displacement. One is to measure the spatial coordinates of measuring points by analyzing the images. Then, the displacement vectors of these points can be calculated using the spatial coordinates of these points obtained at different stages. The other is to calibrate the parameters for individual measuring points locally. Then, the local displacements of these points can be measured directly. This study proposes a simple local three-dimensional displacement measurement method. Without any complicated distortion correction processes, this method can be used to measure small displacement in the three-dimensional space through asimple calibration process. A laboratory experiment and field experiment are carried out to prove the accuracy of this proposed method. Laboratory test errors of one-dimensional experiment are similar to the accuracy of theXYZ table; the error in Z-direction is only 0.0025% of the object distance. The measurement error of laboratory test is about 0.0033% of the object distance for local three-dimensional displacement measurement test. Test and analysis results of field test display that in-plane displacement error is only 0.12 mm, and the out-of-plane error is 1.1 mm for 20 m 9 30 m measuring range. The out-of-plane error is only about 10 PPM of the object distance. These test and analysis results show that this proposed method can achieve very high accuracy under small displacement for both of laboratory and field tests.

  1. Horizontal Positional Accuracy of Google Earth's High-Resolution Imagery Archive.

    Science.gov (United States)

    Potere, David

    2008-12-08

    Google Earth now hosts high-resolution imagery that spans twenty percent of the Earth's landmass and more than a third of the human population. This contemporary highresolution archive represents a significant, rapidly expanding, cost-free and largely unexploited resource for scientific inquiry. To increase the scientific utility of this archive, we address horizontal positional accuracy (georegistration) by comparing Google Earth with Landsat GeoCover scenes over a global sample of 436 control points located in 109 cities worldwide. Landsat GeoCover is an orthorectified product with known absolute positional accuracy of less than 50 meters root-mean-squared error (RMSE). Relative to Landsat GeoCover, the 436 Google Earth control points have a positional accuracy of 39.7 meters RMSE (error magnitudes range from 0.4 to 171.6 meters). The control points derived from satellite imagery have an accuracy of 22.8 meters RMSE, which is significantly more accurate than the 48 control-points based on aerial photography (41.3 meters RMSE; t-test p-value Google Earth highresolution imagery has a horizontal positional accuracy that is sufficient for assessing moderate-resolution remote sensing products across most of the world's peri-urban areas.

  2. Determining dynamical parameters of the Milky Way Galaxy based on high-accuracy radio astrometry

    Science.gov (United States)

    Honma, Mareki; Nagayama, Takumi; Sakai, Nobuyuki

    2015-08-01

    In this paper we evaluate how the dynamical structure of the Galaxy can be constrained by high-accuracy VLBI (Very Long Baseline Interferometry) astrometry such as VERA (VLBI Exploration of Radio Astrometry). We generate simulated samples of maser sources which follow the gas motion caused by a spiral or bar potential, with their distribution similar to those currently observed with VERA and VLBA (Very Long Baseline Array). We apply the Markov chain Monte Carlo analyses to the simulated sample sources to determine the dynamical parameter of the models. We show that one can successfully determine the initial model parameters if astrometric results are obtained for a few hundred sources with currently achieved astrometric accuracy. If astrometric data are available from 500 sources, the expected accuracy of R0 and Θ0 is ˜ 1% or higher, and parameters related to the spiral structure can be constrained by an error of 10% or with higher accuracy. We also show that the parameter determination accuracy is basically independent of the locations of resonances such as corotation and/or inner/outer Lindblad resonances. We also discuss the possibility of model selection based on the Bayesian information criterion (BIC), and demonstrate that BIC can be used to discriminate different dynamical models of the Galaxy.

  3. Two-step Structural Design of Mesh Antennas for High Beam Pointing Accuracy

    Science.gov (United States)

    Zhang, Shuxin; Du, Jingli; Wang, Wei; Zhang, Xinghua; Zong, Yali

    2017-05-01

    A well-designed reflector surface with high beam pointing accuracy in electromagnetic performance is of practical significance to the space application of cable mesh reflector antennas. As for space requirements, circular polarizations are widely used in spaceborne antennas, which usually lead to a beam shift for offset reflectors and influence the beam pointing accuracy. A two-step structural design procedure is proposed to overcome the beam squint phenomenon for high beam pointing accuracy design of circularly polarized offset cable mesh reflectors. A simple structural optimal design and an integrated structural electromagnetic optimization are combined to alleviate the beam squint effect of circular polarizations. It is implemented by cable pretension design and adjustment to shape the offset cable mesh surface. Besides, in order to increase the efficiency of integrated optimization, an update Broyden-Fletcher-Goldfarb-Shanno (BFGS) Hessian matrix is employed in the optimization iteration with sequential quadratic programming. A circularly polarized offset cable mesh reflector is utilized to show the feasibility and effectiveness of the proposed procedure. A high beam pointing accuracy in order of 0.0001º of electromagnetic performance is achieved.

  4. A Simple HPLC-DAD Method for the Analysis of Melamine in Protein Supplements: Validation Using the Accuracy Profiles

    Directory of Open Access Journals (Sweden)

    Domenico Montesano

    2013-01-01

    Full Text Available The study presents a fully validated simple high-performance liquid chromatography method with diode array detection (HPLC-DAD, able to accurately determine the melamine, fraudulently added, in protein supplements, commonly used from healthy adults to enhance exercise or sport performance. The validation strategy was intentionally oriented towards routine use and the reliability of the method rather than extreme performance. For this reason, validation by accuracy profile, including estimation of uncertainty, was chosen. This procedure, based on the concept of total error (bias + standard deviation, clearly showed that this method was able to determine melamine over the range of 0.05–3.0 mg Kg−1, selected by taking into account the maximum residue levels (MRLs proposed by European legislation to distinguish between the unavoidable background presence of melamine and unacceptable adulteration. The accuracy profile procedure established that at least 95% of the future results obtained with the proposed method would be within the ±15% acceptance limits of the validated HPLC-DAD method over the whole defined concentration range.

  5. The Impact of the Implementation of Edge Detection Methods on the Accuracy of Automatic Voltage Reading

    Science.gov (United States)

    Sidor, Kamil; Szlachta, Anna

    2017-04-01

    The article presents the impact of the edge detection method in the image analysis on the reading accuracy of the measured value. In order to ensure the automatic reading of the measured value by an analog meter, a standard webcam and the LabVIEW programme were applied. NI Vision Development tools were used. The Hough transform was used to detect the indicator. The programme output was compared during the application of several methods of edge detection. Those included: the Prewitt operator, the Roberts cross, the Sobel operator and the Canny edge detector. The image analysis was made for an analog meter indicator with the above-mentioned methods, and the results of that analysis were compared with each other and presented.

  6. The Impact of the Implementation of Edge Detection Methods on the Accuracy of Automatic Voltage Reading

    Directory of Open Access Journals (Sweden)

    Sidor Kamil

    2017-04-01

    Full Text Available The article presents the impact of the edge detection method in the image analysis on the reading accuracy of the measured value. In order to ensure the automatic reading of the measured value by an analog meter, a standard webcam and the LabVIEW programme were applied. NI Vision Development tools were used. The Hough transform was used to detect the indicator. The programme output was compared during the application of several methods of edge detection. Those included: the Prewitt operator, the Roberts cross, the Sobel operator and the Canny edge detector. The image analysis was made for an analog meter indicator with the above-mentioned methods, and the results of that analysis were compared with each other and presented.

  7. The accuracy of 15 - 25 years age estimation using panoramic radiograph with thevissen method in Indonesia

    Science.gov (United States)

    Hidayati, D. S.; Suryonegoro, H.; Makes, B. N.

    2017-08-01

    Age estimation is important for individual identification. Root development of third molars occurs at age 15-25 years. This study was conducted to determine the accuracy of age estimation using the Thevissen method in Indonesia. The Thevissen method was applied to 100 panoramic radiographs of both male and female subjects. Reliability was tested by the Dahlberg formula and Cohen’s Kappa test, and the significance measurement was tested by the paired t-test and the Wilcoxon test. The deviation of estimated age was then calculated. The deviation of age estimation was ±3.050 years and ±2.067 for male and female subjects, respectively. The deviation of age estimation of female subjects was less than male subject. Age estimation with the Thevissen method is preferred for age 15-22 years.

  8. Subglacial bedform orientation, one-dimensional size, and directional shape measurement method accuracy

    Science.gov (United States)

    Jorge, Marco G.; Brennand, Tracy A.

    2016-04-01

    This study is an assessment of previously reported automated methods and of a new method for measuring longitudinal subglacial bedform (LSB) morphometry. It evaluates the adequacy (accuracy and precision) of orientation, length and longitudinal asymmetry data derived from the longest straight line (LSL) enclosed by the LSB's footprint, the footprint's minimum bounding rectangle longitudinal axis (RLA) and the footprint's standard deviational ellipse (SDE) longitudinal axis (LA) (new method), and the adequacy of length based on an ellipse fitted to the area and perimeter of the footprint (elliptical length). Tests are based on 100 manually mapped drumlins and mega-scale glacial lineations representing the size and shape range of LSBs in the Puget Lowland drumlin field, WA, USA. Data from manually drawn LAs are used as reference for method evaluation. With the exception of elliptical length, errors decrease rapidly with increasing footprint elongation (decreasing potential angular divergence between LAs). For LSBs with elongation methods had very small mean absolute error (MAE) in all measures (e.g., MAE method should be avoided for orientation (36% of the errors were larger than 5°). 3) Elliptical length was the least accurate of all methods (MAE of 56.1 m and 15% of the errors larger than 5%); its use should be discontinued. 4) The relative adequacy of the LSL and RLA depends on footprint shape; SDE computed with the footprint's structural vertices is relatively shape-independent and is the preferred method. This study is significant also for negative-relief, and fluvial and aeolian bedforms.

  9. Photogrammetric determinaiton of coordinates and deformations analysis of the accuracy of this method

    Energy Technology Data Exchange (ETDEWEB)

    Korablev, D.P.; Fomichev, L.V.; Trunin, A.P.

    1979-01-01

    The photogrammetric method for determining coordinates and deformation, developed at the VNIMI, is based on the analytic determination of the coordinates of points of the sample from measurements of a single stereogram or photograph. The measurements are closely controlled. Calculations are done on a computer. In addition to calculating the point coordinates and various deformation values (vertical and horizontal displacements, slopes, deflections etc.), the accuracy of the results is evaluated: the standard deviation per unit mass, the rms errors of the adjusted values of photo orientation on real photographs and analytical models. The following conclusions and assumptions were obtained on the basis of these studies: 1. When finding the deformation of a flat object, if the points of the last deformation show practically no displacement in the direction normal to the flat surface, then the photos should be taken separately and processed by analytical transformational or by the parallax method, measured from stereograms with a ''time basis''. 2. Then using convergent photography, there is a significant increase in the accuracy of the coordinate determination in the direction perpendicular to the photographic reference line, while there is almost no change in accuracy along the two other axes when compared to normal photography. Optimal symmetric-convergent exposure has a convergence angle of 60 to 120 /sup 0/ and a 1.5 to 2 ratio of the photographic reference line to the average distance to the object (along a normal to the reference). The stereogram of the symmetric-convergent photography for 100% coverage of the photographs encompasses an area two to three times larger than the usual steoegram. 3. The distribution of the reference points should be considered optimal when they bound the working area of the photograph (stereogram). When photographing volumes, they bound the object in the plan and side views.

  10. A High Accuracy Compact Difference Method for 3D Convection-diffusion Equation on Non-uniform Grid%非均匀网格上三维对流扩散方程高精度紧致差分方法

    Institute of Scientific and Technical Information of China (English)

    田芳

    2012-01-01

    利用降维法推导出非均匀网格上三维对流扩散方程的高精度紧致差分格式,对于离散得到的代数方程组采用BiCGStab(2)迭代法求解.数值算例表明,在网格节点数相同的情况下,基于非均匀网格的计算格式较均匀网格格式具有高精度、高分辨率的优点,对于含边界层的对流扩散问题有很好的适应性.%Based on the method of dimension reduction) a high accuracy compact finite difference scheme on non-uniform grid is deduced for 3D convection-diffusion equation and the BiCGStab(2) method (the hybrid bi-conjugate gradient stabilized method) is employed to solve the resulting algebra systems. A numerical experiment is used to show that the present scheme has many advantages such as yielding more accurate numerical solutions, having high resolution for the boundary layers, being well suitable for both convection-dominant and diffusion-dominant problems, and so on. It is also pointed out that the appropriate structure of a non-uniform grid can lead to a solution superior to that for a uniform grid structure with the same number of grid points.

  11. Evaluation of Heart Rate Assessment Timing, Communication, Accuracy, and Clinical Decision-Making during High Fidelity Simulation of Neonatal Resuscitation

    Directory of Open Access Journals (Sweden)

    Win Boon

    2014-01-01

    Full Text Available Objective. Accurate heart rate (HR determination during neonatal resuscitation (NR informs subsequent NR actions. This study’s objective was to evaluate HR determination timeliness, communication, and accuracy during high fidelity NR simulations that house officers completed during neonatal intensive care unit (NICU rotations. Methods. In 2010, house officers in NICU rotations completed high fidelity NR simulation. We reviewed 80 house officers’ videotaped performance on their initial high fidelity simulation session, prior to training and performance debriefing. We calculated the proportion of cases congruent with NR guidelines, using chi square analysis to evaluate performance across HR ranges relevant to NR decision-making: <60, 60–99, and ≥100 beats per minute (bpm. Results. 87% used umbilical cord palpation, 57% initiated HR assessment within 30 seconds, 70% were accurate, and 74% were communicated appropriately. HR determination accuracy varied significantly across HR ranges, with 87%, 57%, and 68% for HR <60, 60–99, and ≥100 bpm, respectively (P<0.001. Conclusions. Timeliness, communication, and accuracy of house officers’ HR determination are suboptimal, particularly for HR 60–100 bpm, which might lead to inappropriate decision-making and NR care. Training implications include emphasizing more accurate HR determination methods, better communication, and improved HR interpretation during NR.

  12. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes

    Science.gov (United States)

    Zhang, Yichi; Liang, Xiao Ying; Liu, Shu; Lee, Jacky W. Y.; Bhaskar, Srinivasan; Lam, Dennis S. C.

    2016-01-01

    Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group for Laser Interference Biometry (ULIB) constants were evaluated and compared. Results. One hundred seventy-one eyes were enrolled. The Barrett Universal II formula had the lowest mean absolute error (MAE) and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas. The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas. The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.). Conclusions. Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas. For high myopic eyes, the Barrett Universal II formula may be a more suitable choice. PMID:27119018

  13. Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes

    Directory of Open Access Journals (Sweden)

    Yichi Zhang

    2016-01-01

    Full Text Available Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL power calculation formulas for eyes with an axial length (AL greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II using User Group for Laser Interference Biometry (ULIB constants were evaluated and compared. Results. One hundred seventy-one eyes were enrolled. The Barrett Universal II formula had the lowest mean absolute error (MAE and SRK/T and Haigis had similar MAE, and the statistical highest MAE were seen with the Holladay and Hoffer Q formulas. The interquartile range of the Barrett Universal II formula was also the lowest among all the formulas. The Barrett Universal II formulas yielded the highest percentage of eyes within ±1.0 D and ±0.5 D of the target refraction in this study (97.24% and 79.56%, resp.. Conclusions. Barrett Universal II formula produced the lowest predictive error and the least variable predictive error compared with the SRK/T, Haigis, Holladay, and Hoffer Q formulas. For high myopic eyes, the Barrett Universal II formula may be a more suitable choice.

  14. Rapid, high-accuracy detection of strabismus and amblyopia using the pediatric vision scanner.

    Science.gov (United States)

    Loudon, Sjoukje E; Rook, Caitlin A; Nassif, Deborah S; Piskun, Nadya V; Hunter, David G

    2011-07-07

    Purpose. The Pediatric Vision Scanner (PVS) detects strabismus by identifying ocular fixation in both eyes simultaneously. This study was undertaken to assess the ability of the PVS to identify patients with amblyopia or strabismus, particularly anisometropic amblyopia with no measurable strabismus. Methods. The PVS test, administered from 40 cm and requiring 2.5 seconds of attention, generated a binocularity score (BIN, 0%-100%). We tested 154 patients and 48 controls between the ages of 2 and 18 years. BIN scores of amblyopic children and controls were measured, and 21 children received sequential PVS measurements to detect any changes in BIN resulting from amblyopia treatment. Results. With the pass/refer threshold set at BIN 60%, sensitivity and specificity were 96% for the detection of amblyopia or strabismus. Assuming a 5% prevalence of amblyopia or strabismus, the inferred positive and negative predictive values of the PVS were 56% and 100%, respectively. Fixation accuracy was significantly reduced in amblyopic eyes. In anisometropic amblyopia patients treated successfully, the BIN improved to 100%. Conclusions. The PVS identified children with amblyopia or strabismus with high sensitivity and specificity, while successful treatment restored normal BIN scores in amblyopic patients without strabismus. The results support the hypothesis that the PVS detects strabismus and amblyopia directly. Future strategies for screening by nonspecialists may thus be based on diagnostic detection of amblyopia and strabismus rather than the estimation of risk factors, allowing for rapid, accurate identification of children with amblyopia early in life when it is most amenable to treatment.

  15. Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer

    Directory of Open Access Journals (Sweden)

    Akifumi Takanabe

    2017-02-01

    Full Text Available A fast, high-accuracy universal polarimeter was developed using a charge-coupled device (CCD spectrometer (CCD-HAUP, to carry out simultaneous optical anisotropic (linear birefringence, LB; linear dichroism, LD and chiroptical (circular birefringence, CB; circular dichroism, CD measurements on single crystals without any pretreatment, in the visible region between 400–680 nm. The principle of the HAUP method is to measure the intensities of emergent light passing through a polarizer, a crystal sample, and then an analyzer, as the azimuth angles of the polarizer and analyzer are independently altered. The CCD-HAUP has the unique feature that white transmitted light intensity can be measured using a CCD spectrometer, compared with the generalized HAUP (G-HAUP system in which monochromatic transmitted light is measured using a photomultiplier. The CCD-HAUP measurements across the entire wavelength region are completed within the G-HAUP measurement time for a single wavelength. The CCD-HAUP drastically reduces the measurement time for a dataset to only 1.5 h, from the 24 h required for the G-HAUP system. LB, LD, CB, and CD measurements of single crystals of α-quartz and enantiomeric photomechanical salicylidenephenylethylamines before, during, and after ultraviolet light irradiation show results comparable to those obtained using the G-HAUP system. The newly developed system is very effective for samples susceptible to degradation induced by external stimuli, such as light and heat.

  16. The Impact of Ionospheric Disturbances on High Accuracy Positioning in Brazil

    Science.gov (United States)

    Yang, L.; Park, J.; Susnik, A.; Aquino, M. H.; Dodson, A.

    2013-12-01

    High positioning accuracy is a key requirement to a number of applications with a high economic impact, such as precision agriculture, surveying, geodesy, land management, off-shore operations. Global Navigation Satellite Systems (GNSS) carrier phase measurement based techniques, such as Real Time Kinematic (RTK), Network-RTK (NRTK) and Precise Point Positioning (PPP), have played an important role in providing centimetre-level positioning accuracy, and become the core of the above applications. However these techniques are especially sensitive to ionospheric perturbations, in particular scintillation. Brazil sits in one of the most affected regions of the Earth and can be regarded as a test-bed for scenarios of the severe ionospheric condition. Over the Brazilian territory, the ionosphere behaves in a considerably unpredictable way and scintillation activity is very prominent, occurring especially after sunset hours. NRTK services may not be able to provide satisfactory accuracy, or even continuous positioning during strong scintillation periods. CALIBRA (Countering GNSS high Accuracy applications Limitations due to Ionospheric disturbances in BRAzil) started in late 2012 and is a project funded by the GSA (European GNSS Agency) and the European Commission under the Framework Program 7 to deliver improvements on carrier phase based high accuracy algorithms and their implementation in GNSS receivers, aiming to counter the adverse ionospheric effects over Brazil. As the first stage of this project, the ionospheric disturbances, which affect the applications of RTK, NRTK or PPP, are characterized. Typical problems include degraded positioning accuracy, difficulties in ambiguity fixing, NRTK network interpolation errors, long PPP convergence time etc. It will identify how GNSS observables and existing algorithms are degraded by ionosphere related phenomena, evaluating the impact on positioning techniques in terms of accuracy, integrity and availability. Through the

  17. Hybrid head-tracker being examined for the high-accuracy attack rotorcraft market

    Science.gov (United States)

    Blanton, Buddy

    2002-08-01

    The need for the helmet-mounted display (HMD) to present flight, navigation, and weapon information in the pilot's line-of-sight has continued to rise as helicopter missions increase in complexity. To obtain spatial correlation of the direction of the head line-of-sight and pilotage imagery generated from helicopter-mounted sensors, it is necessary to slave the sensors to the head motion. To accomplish this task, a head-tracking system (HTS) must be incorporated into the HMD. There are a variety of techniques that could be applied for locating the position and attitude of a helmet-mounted display. Regardless of the technology, an HTS must provide defined measurements of accuracy. System parameters include motion box size, angular range, pointing angle accuracy, pointing angle resolution, update rate, and slew rate. This paper focuses on a hybrid tracker implementation in which a combination of optical and inertial tracking using strap-down gyros is preferred. Specifically, this tracker implementation is being examined for the high-accuracy attack rotorcraft market which requires a high degree of accuracy. The performance and resultant cost of the tracker components are determined by the specific needs of the intended application. The paper will also indicate how the various requirements drive the cost, configuration, and performance of the resultant hybrid head-tracker.

  18. Literature survey of high-impact journals revealed reporting weaknesses in abstracts of diagnostic accuracy studies.

    Science.gov (United States)

    Korevaar, Daniël A; Cohen, Jérémie F; Hooft, Lotty; Bossuyt, Patrick M M

    2015-06-01

    Informative journal abstracts are crucial for the identification and initial appraisal of studies. We aimed to evaluate the informativeness of abstracts of diagnostic accuracy studies. PubMed was searched for reports of studies that had evaluated the diagnostic accuracy of a test against a clinical reference standard, published in 12 high-impact journals in 2012. Two reviewers independently evaluated the information contained in included abstracts using 21 items deemed important based on published guidance for adequate reporting and study quality assessment. We included 103 abstracts. Crucial information on study population, setting, patient sampling, and blinding as well as confidence intervals around accuracy estimates were reported in items per abstract was 10.1 of 21 (standard deviation 2.2). The mean number of reported items was significantly lower for multiple-gate (case-control type) studies, in reports in specialty journals, and for studies with smaller sample sizes and lower abstract word counts. No significant differences were found between studies evaluating different types of tests. Many abstracts of diagnostic accuracy study reports in high-impact journals are insufficiently informative. Developing guidelines for such abstracts could help the transparency and completeness of reporting. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. High accuracy digital aging monitor based on PLL-VCO circuit

    Science.gov (United States)

    Yuejun, Zhang; Zhidi, Jiang; Pengjun, Wang; Xuelong, Zhang

    2015-01-01

    As the manufacturing process is scaled down to the nanoscale, the aging phenomenon significantly affects the reliability and lifetime of integrated circuits. Consequently, the precise measurement of digital CMOS aging is a key aspect of nanoscale aging tolerant circuit design. This paper proposes a high accuracy digital aging monitor using phase-locked loop and voltage-controlled oscillator (PLL-VCO) circuit. The proposed monitor eliminates the circuit self-aging effect for the characteristic of PLL, whose frequency has no relationship with circuit aging phenomenon. The PLL-VCO monitor is implemented in TSMC low power 65 nm CMOS technology, and its area occupies 303.28 × 298.94 μm2. After accelerating aging tests, the experimental results show that PLL-VCO monitor improves accuracy about high temperature by 2.4% and high voltage by 18.7%.

  20. High accuracy acoustic relative humidity measurement in duct flow with air.

    Science.gov (United States)

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

  1. Evaluation of Different Estimation Methods for Accuracy and Precision in Biological Assay Validation.

    Science.gov (United States)

    Yu, Binbing; Yang, Harry

    2017-01-01

    Biological assays (bioassays) are procedures to estimate the potency of a substance by studying its effects on living organisms, tissues, and cells. Bioassays are essential tools for gaining insight into biologic systems and processes including, for example, the development of new drugs and monitoring environmental pollutants. Two of the most important parameters of bioassay performance are relative accuracy (bias) and precision. Although general strategies and formulas are provided in USP, a comprehensive understanding of the definitions of bias and precision remain elusive. Additionally, whether there is a beneficial use of data transformation in estimating intermediate precision remains unclear. Finally, there are various statistical estimation methods available that often pose a dilemma for the analyst who must choose the most appropriate method. To address these issues, we provide both a rigorous definition of bias and precision as well as three alternative methods for calculating relative standard deviation (RSD). All methods perform similarly when the RSD ≤10%. However, the USP estimates result in larger bias and root-mean-square error (RMSE) compared to the three proposed methods when the actual variation was large. Therefore, the USP method should not be used for routine analysis. For data with moderate skewness and deviation from normality, the estimates based on the original scale perform well. The original scale method is preferred, and the method based on log-transformation may be used for noticeably skewed data.LAY ABSTRACT: Biological assays, or bioassays, are essential in the development and manufacture of biopharmaceutical products for potency testing and quality monitoring. Two important parameters of assay performance are relative accuracy (bias) and precision. The definitions of bias and precision in USP 〈1033〉 are elusive and confusing. Another complicating issue is whether log-transformation should be used for calculating the

  2. Measurement of glomerular filtration rate in adults: accuracy of five single-sample plasma clearance methods

    DEFF Research Database (Denmark)

    Rehling, M; Rabøl, A

    1989-01-01

    After an intravenous injection of a tracer that is removed from the body solely by filtration in the kidneys, the glomerular filtration rate (GFR) can be determined from its plasma clearance. The method requires a great number of blood samples but collection of urine is not needed. In the present......-acetate) was determined simultaneously. Using these clearance values as reference the accuracy of six simplified methods were studied: five single-sample methods and one five-sample method. The standard error of estimate (SEE) of the single-sample methods ranged from 4.2 to 7.5 ml min-1 using EDTA, and from 3.8 to 6.3 ml...... min-1 using DTPA. SEE of the five-samples method was 3.0 ml min-1 (EDTA) and 3.1 ml min-1 (DTPA). The single-sample methods given by Christensen & Groth (1986) and by Tauxe (1986) are recommended for daily use, as SEE was small even at low GFR values. In patients with GFR less than 80 ml min-1...

  3. VIKOR method with enhanced accuracy for multiple criteria decision making in healthcare management.

    Science.gov (United States)

    Zeng, Qiang-Lin; Li, Dan-Dan; Yang, Yi-Bin

    2013-04-01

    Višekriterijumsko kompromisno rangiranje (VIKOR) method is one of the commonly used multi criteria decision making (MCDM) methods for improving the quality of decision making. VIKOR has an advantage in providing a ranking procedure for positive attributes and negative attributes when it is used and examined in decision support. However, we noticed that this method may failed to support an objective result in medical field because most medical data have normal reference ranges (e.g., for normally distributed data: NRR ∈ [μ ± 1.96σ], this limitation shows a negative effect on the acceptance of it as an effective decision supporting method in medical decision making. This paper proposes an improved VIKOR method with enhanced accuracy (ea-VIKOR) to make it suitable for such data in medical field by introducing a new data normalization method taking the original distance to the normal reference range (ODNRR) into account. In addition, an experimental example was presented to demonstrate efficiency and feasibility of the ea-VIKOR method, the results demonstrate the ability of ea-VIKOR to deal with moderate data and support the decision making in healthcare care management. For this reason, the ea-VIKOR should be considered for use as a decision support tool for future study.

  4. Dimensional accuracy of acrylic resin maxillary denture base polymerized by a new injection pressing method.

    Science.gov (United States)

    Ono, Takahiro; Kita, Seiichi; Nokubi, Takashi

    2004-09-01

    The purpose of this study was to confirm the dimensional accuracy of a newly developed injection pressing method for resin polymerization by making use of the internal electric resistance of resin to determine the optimal timing for resin injection. A new injection pressing polymerization pot with a built-in system to measure the internal electric resistance of resin was used for resin polymerization. Fluid-type resin was injected into the mold of a maxillary complete denture base under nine different conditions: three different timings for resin injection according to the electric resistance of resin dough (early stage: 11 Mohms; intermediate stage: 16 Mohms; final stage: 21 Mohms) and three different motor powers for resin injection (2000 N, 4000 N, and 6000 N). In the best polymerization condition (injected during the early stage of resin dough under a motor power of 6000 N), the adaptation of the denture base showed a statistically significant improvement compared with the conventional pouring method.

  5. Methods used by Elsam for monitoring precision and accuracy of analytical results

    Energy Technology Data Exchange (ETDEWEB)

    Hinnerskov Jensen, J. [Soenderjyllands Hoejspaendingsvaerk, Faelleskemikerne, Aabenraa (Denmark)

    1996-12-01

    Performing round robins at regular intervals is the primary method used by ELsam for monitoring precision and accuracy of analytical results. The firs round robin was started in 1974, and today 5 round robins are running. These are focused on: boiler water and steam, lubricating oils, coal, ion chromatography and dissolved gases in transformer oils. Besides the power plant laboratories in Elsam, the participants are power plant laboratories from the rest of Denmark, industrial and commercial laboratories in Denmark, and finally foreign laboratories. The calculated standard deviations or reproducibilities are compared with acceptable values. These values originate from ISO, ASTM and the like, or from own experiences. Besides providing the laboratories with a tool to check their momentary performance, the round robins are vary suitable for evaluating systematic developments on a long term basis. By splitting up the uncertainty according to methods, sample preparation/analysis, etc., knowledge can be extracted from the round robins for use in many other situations. (au)

  6. High Mass Accuracy and High Mass Resolving Power FT-ICR Secondary Ion Mass Spectrometry for Biological Tissue Imaging

    CERN Document Server

    Smith, Donald F; Leach, Franklin E; Robinson, Errol W; Paša-Tolić, Ljiljana; Heeren, Ron M A

    2013-01-01

    Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the sub-micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for elemental formula assignment based on exact mass measurement. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissu...

  7. Confusion assessment method: a systematic review and meta-analysis of diagnostic accuracy

    Directory of Open Access Journals (Sweden)

    Shi Q

    2013-09-01

    Full Text Available Qiyun Shi,1,2 Laura Warren,3 Gustavo Saposnik,2 Joy C MacDermid1 1Health and Rehabilitation Sciences, Western University, London, Ontario, Canada; 2Stroke Outcomes Research Center, Department of Medicine, St Michael's Hospital, University of Toronto, Toronto, Ontario, Canada; 3Dalla Lana School of Public Health, University of Toronto, Toronto, Ontario, Canada Background: Delirium is common in the early stages of hospitalization for a variety of acute and chronic diseases. Objectives: To evaluate the diagnostic accuracy of two delirium screening tools, the Confusion Assessment Method (CAM and the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU. Methods: We searched MEDLINE, EMBASE, and PsychInfo for relevant articles published in English up to March 2013. We compared two screening tools to Diagnostic and Statistical Manual of Mental Disorders IV criteria. Two reviewers independently assessed studies to determine their eligibility, validity, and quality. Sensitivity and specificity were calculated using a bivariate model. Results: Twenty-two studies (n = 2,442 patients met the inclusion criteria. All studies demonstrated that these two scales can be administered within ten minutes, by trained clinical or research staff. The pooled sensitivities and specificity for CAM were 82% (95% confidence interval [CI]: 69%–91% and 99% (95% CI: 87%–100%, and 81% (95% CI: 57%–93% and 98% (95% CI: 86%–100% for CAM-ICU, respectively. Conclusion: Both CAM and CAM-ICU are validated instruments for the diagnosis of delirium in a variety of medical settings. However, CAM and CAM-ICU both present higher specificity than sensitivity. Therefore, the use of these tools should not replace clinical judgment. Keywords: confusion assessment method, diagnostic accuracy, delirium, systematic review, meta-analysis

  8. Affine-Invariant Geometric Constraints-Based High Accuracy Simultaneous Localization and Mapping

    Directory of Open Access Journals (Sweden)

    Gangchen Hua

    2017-01-01

    Full Text Available In this study we describe a new appearance-based loop-closure detection method for online incremental simultaneous localization and mapping (SLAM using affine-invariant-based geometric constraints. Unlike other pure bag-of-words-based approaches, our proposed method uses geometric constraints as a supplement to improve accuracy. By establishing an affine-invariant hypothesis, the proposed method excludes incorrect visual words and calculates the dispersion of correctly matched visual words to improve the accuracy of the likelihood calculation. In addition, camera’s intrinsic parameters and distortion coefficients are adequate for this method. 3D measuring is not necessary. We use the mechanism of Long-Term Memory and Working Memory (WM to manage the memory. Only a limited size of the WM is used for loop-closure detection; therefore the proposed method is suitable for large-scale real-time SLAM. We tested our method using the CityCenter and Lip6Indoor datasets. Our proposed method results can effectively correct the typical false-positive localization of previous methods, thus gaining better recall ratios and better precision.

  9. Accuracy assessment of blind and semi-blind restoration methods for hyperspectral images

    Science.gov (United States)

    Zhang, Mo; Vozel, Benoit; Chehdi, Kacem; Uss, Mykhail; Abramov, Sergey; Lukin, Vladimir

    2016-10-01

    Hyperspectral images acquired by remote sensing systems are generally degraded by noise and can be sometimes more severely degraded by blur. When no knowledge is available about the degradations present or the original image, blind restoration methods must be considered. Otherwise, when a partial information is needed, semi-blind restoration methods can be considered. Numerous semi-blind and quite advanced methods are available in the literature. So to get better insights and feedback on the applicability and potential efficiency of a representative set of four semi-blind methods recently proposed, we have performed a comparative study of these methods in objective terms of blur filter and original image error estimation accuracy. In particular, we have paid special attention to the accurate recovering in the spectral dimension of original spectral signatures. We have analyzed peculiarities and factors restricting the applicability of these methods. Our tests are performed on a synthetic hyperspectral image, degraded with various synthetic blurs (out-of-focus, gaussian, motion) and with signal independent noise of typical levels such as those encountered in real hyperspectral images. This synthetic image has been built from various samples from classified areas of a real-life hyperspectral image, in order to benefit from realistic reference spectral signatures to recover after synthetic degradation. Conclusions, practical recommendations and perspectives are drawn from the results experimentally obtained.

  10. A method for improved accuracy in three dimensions for determining wheel/rail contact points

    Science.gov (United States)

    Yang, Xinwen; Gu, Shaojie; Zhou, Shunhua; Zhou, Yu; Lian, Songliang

    2015-11-01

    Searching for the contact points between wheels and rails is important because these points represent the points of exerted contact forces. In order to obtain an accurate contact point and an in-depth description of the wheel/rail contact behaviours on a curved track or in a turnout, a method with improved accuracy in three dimensions is proposed to determine the contact points and the contact patches between the wheel and the rail when considering the effect of the yaw angle and the roll angle on the motion of the wheel set. The proposed method, with no need of the curve fitting of the wheel and rail profiles, can accurately, directly, and comprehensively determine the contact interface distances between the wheel and the rail. The range iteration algorithm is used to improve the computation efficiency and reduce the calculation required. The present computation method is applied for the analysis of the contact of rails of CHINA (CHN) 75 kg/m and wheel sets of wearing type tread of China's freight cars. In addition, it can be proved that the results of the proposed method are consistent with that of Kalker's program CONTACT, and the maximum deviation from the wheel/rail contact patch area of this two methods is approximately 5%. The proposed method, can also be used to investigate static wheel/rail contact. Some wheel/rail contact points and contact patch distributions are discussed and assessed, wheel and rail non-worn and worn profiles included.

  11. Accuracy of Nearly Extinct Cohort Methods for Estimating Very Elderly Subnational Populations

    Directory of Open Access Journals (Sweden)

    Wilma Terblanche

    2015-01-01

    Full Text Available Increasing very elderly populations (ages 85+ have potentially major implications for the cost of income support, aged care, and healthcare. The availability of accurate estimates for this population age group, not only at a national level but also at a state or regional scale, is vital for policy development, budgeting, and planning for services. At the highest ages census-based population estimates are well known to be problematic and previous studies have demonstrated that more accurate estimates can be obtained indirectly from death data. This paper assesses indirect estimation methods for estimating state-level very elderly populations from death counts. A method for incorporating internal migration is also proposed. The results confirm that the accuracy of official estimates deteriorates rapidly with increasing age from 95 and that the survivor ratio method can be successfully applied at subnational level and internal migration is minor. It is shown that the simpler alternative of applying the survivor ratio method at a national level and apportioning the estimates between the states produces very accurate estimates for most states and years. This is the recommended method. While the methods are applied at a state level in Australia, the principles are generic and are applicable to other subnational geographies.

  12. A High-Accuracy Linear Conservative Difference Scheme for Rosenau-RLW Equation

    Directory of Open Access Journals (Sweden)

    Jinsong Hu

    2013-01-01

    Full Text Available We study the initial-boundary value problem for Rosenau-RLW equation. We propose a three-level linear finite difference scheme, which has the theoretical accuracy of Oτ2+h4. The scheme simulates two conservative properties of original problem well. The existence, uniqueness of difference solution, and a priori estimates in infinite norm are obtained. Furthermore, we analyze the convergence and stability of the scheme by energy method. At last, numerical experiments demonstrate the theoretical results.

  13. High-accuracy current measurement with low-cost shunts by means of dynamic error correction

    OpenAIRE

    Weßkamp, Patrick; Melbert, Joachim

    2016-01-01

    Measurement of electrical current is often performed by using shunt resistors. Thermal effects due to self-heating and ambient temperature variation limit the achievable accuracy, especially if low-cost shunt resistors with increased temperature coefficients are utilized. In this work, a compensation method is presented which takes static and dynamic temperature drift effects into account and provides a significant reduction of measurement error. A thermal model of the shunt...

  14. RNA secondary structure modeling at consistent high accuracy using differential SHAPE.

    Science.gov (United States)

    Rice, Greggory M; Leonard, Christopher W; Weeks, Kevin M

    2014-06-01

    RNA secondary structure modeling is a challenging problem, and recent successes have raised the standards for accuracy, consistency, and tractability. Large increases in accuracy have been achieved by including data on reactivity toward chemical probes: Incorporation of 1M7 SHAPE reactivity data into an mfold-class algorithm results in median accuracies for base pair prediction that exceed 90%. However, a few RNA structures are modeled with significantly lower accuracy. Here, we show that incorporating differential reactivities from the NMIA and 1M6 reagents--which detect noncanonical and tertiary interactions--into prediction algorithms results in highly accurate secondary structure models for RNAs that were previously shown to be difficult to model. For these RNAs, 93% of accepted canonical base pairs were recovered in SHAPE-directed models. Discrepancies between accepted and modeled structures were small and appear to reflect genuine structural differences. Three-reagent SHAPE-directed modeling scales concisely to structurally complex RNAs to resolve the in-solution secondary structure analysis problem for many classes of RNA.

  15. High Accuracy Gravitational Waveforms from Black Hole Binary Inspirals Using OpenCL

    CERN Document Server

    McKennon, Justin; Khanna, Gaurav

    2012-01-01

    There is a strong need for high-accuracy and efficient modeling of extreme-mass-ratio binary black hole systems because these are strong sources of gravitational waves that would be detected by future observatories. In this article, we present sample results from our Teukolsky EMRI code: a time-domain Teukolsky equation solver (a linear, hyperbolic, partial differential equation solver using finite-differencing), that takes advantage of several mathematical and computational enhancements to efficiently generate long-duration and high-accuracy EMRI waveforms. We emphasize here the computational advances made in the context of this code. Currently there is considerable interest in making use of many-core processor architectures, such as Nvidia and AMD graphics processing units (GPUs) for scientific computing. Our code uses the Open Computing Language (OpenCL) for taking advantage of the massive parallelism offered by modern GPU architectures. We present the performance of our Teukolsky EMRI code on multiple mod...

  16. Dimensional accuracy optimization of the micro-plastic injection molding process using the Taguchi design method

    Directory of Open Access Journals (Sweden)

    Chil-Chyuan KUO KUO

    2015-06-01

    Full Text Available Plastic injection molding is an important field in manufacturing industry because there are many plastic products that produced by injection molding. However, the time and cost required for producing a precision mold are the most troublesome problems that limit the application at the development stage of a new product in precision machinery industry. This study presents an approach of manufacturing a hard mold with microfeatures for micro-plastic injection molding. This study also focuses on Taguchi design method for investigating the effect of injection parameters on the dimensional accuracy of Fresnel lens during plastic injection molding. It was found that the dominant factor affecting the microgroove depth of Fresnel lens is packing pressure. The optimum processing parameters are packing pressure of 80 MPa, melt temperature of 240 °C, mold temperature of 90 °C and injection speed of 50 m/s. The dimensional accuracy of Fresnel lens can be controlled within ±3 µm using the optimum level of process parameters through the confirmation test. The research results of this study have industrial application values because electro-optical industries are able to significantly reduce a new optical element development cycle time.DOI: http://dx.doi.org/10.5755/j01.ms.21.2.5864

  17. Using Vicon system and optical method to evaluate inertial and magnetic system accuracy

    Directory of Open Access Journals (Sweden)

    Mansour F.

    2010-06-01

    Full Text Available MEMS are being more accessible thank price and energy consumption. That explains the democratisation of attitude control system. Sensors found in attitude control system are accelerometers, magnetometers and gyrometers. The commercialised solutions are expensive and not optimised in sensors number and energy consumption. Movea’s system is based on low cost sensors, number optimisation and low energy consumption. It is constituted of wireless attitude control system named MotionPOD. The system has two modes: the simulation mode and the reconstruction mode, even for cinematic motions. Movea’s system is seen as a black box which becomes as entries measurements for reconstruction mode and body segment orientation for simulation one. In body motion reconstruction Vicon system is usually used because of its accuracy. With markers position it is easy to compute the orientation of each body segment if we have put enough markers. That is why Vicon system may be a good etalon for the Movea’s system. We present practical approach of the characterisation of Movea’s system and its validation. Thereby we will present criterion useful to evaluate the reconstruction accuracy. Moreover we will insist on optical methods used to extract the interesting data from Vicon.

  18. High-accuracy measurement of ship velocities by DGPS; DGPS ni yoru sensoku keisoku no koseidoka ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, S.; Koterayama, W. [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1996-04-10

    The differential global positioning system (DGPS) can eliminate most of errors in ship velocity measurement by GPS positioning alone. Through two rounds of marine observations by towing an observation robot in summer 1995, the authors attempted high-accuracy measurement of ship velocities by DGPS, and also carried out both positioning by GPS alone and measurement using the bottom track of ADCP (acoustic Doppler current profiler). In this paper, the results obtained by these measurement methods were examined through comparison among them, and the accuracy of the measured ship velocities was considered. In DGPS measurement, both translocation method and interference positioning method were used. ADCP mounted on the observation robot allowed measurement of the velocity of current meter itself by its bottom track in shallow sea areas less than 350m. As the result of these marine observations, it was confirmed that the accuracy equivalent to that of direct measurement by bottom track is possible to be obtained by DGPS. 3 refs., 5 figs., 1 tab.

  19. Shape Optimization of the Turbomachine Channel by a Gradient Method -Accuracy Improvement

    Institute of Scientific and Technical Information of China (English)

    Marek Rabiega

    2003-01-01

    An algorithm of the gradient method of the channel shape optimization has been built on the basis of 3D equations of mass, momentum and energy conservation in the fluid flow. The gradient of the functional that is posed for minimization has been calculated by two methods, via sensitivities and - for comparison - by the finite difference approximation. The equations for sensitivities have been generated through a differentiate-then-discretize approach. The exemplary optimization of the blade shape of the centrifugal compressor wheel has been carried out for the inviscid gas flow governed by Euler equations with a non-uniform mass flow distribution as the inlet boundary condition. Mixing losses have been minimized downstream the outlet of the centrifugal wheel in this exemplary optimization. The results of the optimization problem accomplished by the two above-mentioned methods have been presented. In the case sparse grids have been used, the method with the gradient approximated by finite differences has been found to be more consistent. The discretization accuracy has turned out to be crucial for the consistency of the gradient method via sensitivities.

  20. METHOD OF ACHIEVING ACCURACY OF THERMO-MECHANICAL TREATMENT OF LOW-RIGIDITY SHAFTS

    Directory of Open Access Journals (Sweden)

    Antoni Świć

    2016-03-01

    Full Text Available The paper presents a method combining the processes of straightening and thermal treatment. Technological processes with axial strain were considered, for the case of heated material and without its heating. The essence of the process in the case of heated material consisted in the fact that if under tension all longitudinal forces in the first approximation are uniform - the same strains are generated. The presented technological approach, aimed at reducing the curvature of axial-symmetrical parts, is acceptable as the process of rough, preliminary machining, in the case of shafts with the ratio L/D≤100 (L – shaft length, d – shaft diameter and without a tendency of strengthening. To improve the accuracy and stability of geometric form of low-rigidity parts, a method was developed that combines the processes of straightening and heat treatment. The method consists in that axial strain – tension, is applied to the shaft during heating, and during cooling the product is fixed in a fixture, the cooling rate of the shaft being several-fold greater than that of the fixture. A device is presented for the realisation of the method of controlling the process of plastic deformation of low-rigidity shafts. In the case of the presented device and the adopted calculation scheme, a method was developed that permits the determination of the length of shaft section and of the time of its cooling.

  1. Morphometric measurements of dragonfly wings: the accuracy of pinned, scanned and detached measurement methods

    Directory of Open Access Journals (Sweden)

    Laura Johnson

    2013-03-01

    Full Text Available Large-scale digitization of museum specimens, particularly of insect collections, is becoming commonplace. Imaging increases the accessibility of collections and decreases the need to handle individual, often fragile, specimens. Another potential advantage of digitization is to make it easier to conduct morphometric analyses, but the accuracy of such methods needs to be tested. Here we compare morphometric measurements of scanned images of dragonfly wings to those obtained using other, more traditional, methods. We assume that the destructive method of removing and slide-mounting wings provides the most accurate method of measurement because it eliminates error due to wing curvature. We show that, for dragonfly wings, hand measurements of pinned specimens and digital measurements of scanned images are equally accurate relative to slide-mounted hand measurements. Since destructive slide-mounting is unsuitable for museum collections, and there is a risk of damage when hand measuring fragile pinned specimens, we suggest that the use of scanned images may also be an appropriate method to collect morphometric data from other collected insect species.

  2. Indexing Large Visual Vocabulary by Randomized Dimensions Hashing for High Quantization Accuracy: Improving the Object Retrieval Quality

    Science.gov (United States)

    Yang, Heng; Wang, Qing; He, Zhoucan

    The bag-of-visual-words approach, inspired by text retrieval methods, has proven successful in achieving high performance in object retrieval on large-scale databases. A key step of these methods is the quantization stage which maps the high-dimensional image feature vectors to discriminatory visual words. In this paper, we consider the quantization step as the nearest neighbor search in large visual vocabulary, and thus proposed a randomized dimensions hashing (RDH) algorithm to efficiently index and search the large visual vocabulary. The experimental results have demonstrated that the proposed algorithm can effectively increase the quantization accuracy compared to the vocabulary tree based methods which represent the state-of-the-art. Consequently, the object retrieval performance can be significantly improved by our method in the large-scale database.

  3. Machine learning methods for empirical streamflow simulation: a comparison of model accuracy, interpretability, and uncertainty in seasonal watersheds

    Science.gov (United States)

    Shortridge, Julie E.; Guikema, Seth D.; Zaitchik, Benjamin F.

    2016-07-01

    In the past decade, machine learning methods for empirical rainfall-runoff modeling have seen extensive development and been proposed as a useful complement to physical hydrologic models, particularly in basins where data to support process-based models are limited. However, the majority of research has focused on a small number of methods, such as artificial neural networks, despite the development of multiple other approaches for non-parametric regression in recent years. Furthermore, this work has often evaluated model performance based on predictive accuracy alone, while not considering broader objectives, such as model interpretability and uncertainty, that are important if such methods are to be used for planning and management decisions. In this paper, we use multiple regression and machine learning approaches (including generalized additive models, multivariate adaptive regression splines, artificial neural networks, random forests, and M5 cubist models) to simulate monthly streamflow in five highly seasonal rivers in the highlands of Ethiopia and compare their performance in terms of predictive accuracy, error structure and bias, model interpretability, and uncertainty when faced with extreme climate conditions. While the relative predictive performance of models differed across basins, data-driven approaches were able to achieve reduced errors when compared to physical models developed for the region. Methods such as random forests and generalized additive models may have advantages in terms of visualization and interpretation of model structure, which can be useful in providing insights into physical watershed function. However, the uncertainty associated with model predictions under extreme climate conditions should be carefully evaluated, since certain models (especially generalized additive models and multivariate adaptive regression splines) become highly variable when faced with high temperatures.

  4. A Smart High Accuracy Silicon Piezoresistive Pressure Sensor Temperature Compensation System

    Directory of Open Access Journals (Sweden)

    Guanwu Zhou

    2014-07-01

    Full Text Available Theoretical analysis in this paper indicates that the accuracy of a silicon piezoresistive pressure sensor is mainly affected by thermal drift, and varies nonlinearly with the temperature. Here, a smart temperature compensation system to reduce its effect on accuracy is proposed. Firstly, an effective conditioning circuit for signal processing and data acquisition is designed. The hardware to implement the system is fabricated. Then, a program is developed on LabVIEW which incorporates an extreme learning machine (ELM as the calibration algorithm for the pressure drift. The implementation of the algorithm was ported to a micro-control unit (MCU after calibration in the computer. Practical pressure measurement experiments are carried out to verify the system’s performance. The temperature compensation is solved in the interval from −40 to 85 °C. The compensated sensor is aimed at providing pressure measurement in oil-gas pipelines. Compared with other algorithms, ELM acquires higher accuracy and is more suitable for batch compensation because of its higher generalization and faster learning speed. The accuracy, linearity, zero temperature coefficient and sensitivity temperature coefficient of the tested sensor are 2.57% FS, 2.49% FS, 8.1 × 10−5/°C and 29.5 × 10−5/°C before compensation, and are improved to 0.13%FS, 0.15%FS, 1.17 × 10−5/°C and 2.1 × 10−5/°C respectively, after compensation. The experimental results demonstrate that the proposed system is valid for the temperature compensation and high accuracy requirement of the sensor.

  5. High Mass Accuracy and High Mass Resolving Power FT-ICR Secondary Ion Mass Spectrometry for Biological Tissue Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Donald F.; Kiss, Andras; Leach, Franklin E.; Robinson, Errol W.; Pasa-Tolic, Ljiljana; Heeren, Ronald M.

    2013-07-01

    Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for exact mass elemental formula assignment. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissue was measured with 150 μm spatial resolution (75 μm primary ion spot size) with mass resolving power (m/Δm50%) of 67,500 (at m/z 750) and root-mean-square measurement accuracy less than two parts-per-million for intact phospholipids, small molecules and fragments. For the first time, ultra-high mass resolving power SIMS has been demonstrated, with m/Δm50% > 3,000,000. Higher spatial resolution capabilities of the platform were tested at a spatial resolution of 20 μm. The results represent order of magnitude improvements in mass resolving power and mass measurement accuracy for SIMS imaging and the promise of the platform for ultra-high mass resolving power and high spatial resolution imaging.

  6. Accuracy of GPS devices for measuring high-intensity running in field-based team sports.

    Science.gov (United States)

    Rampinini, E; Alberti, G; Fiorenza, M; Riggio, M; Sassi, R; Borges, T O; Coutts, A J

    2015-01-01

    We compared the accuracy of 2 GPS systems with different sampling rates for the determination of distances covered at high-speed and metabolic power derived from a combination of running speed and acceleration. 8 participants performed 56 bouts of shuttle intermittent running wearing 2 portable GPS devices (SPI-Pro, GPS-5 Hz and MinimaxX, GPS-10 Hz). The GPS systems were compared with a radar system as a criterion measure. The variables investigated were: total distance (TD), high-speed distance (HSR>4.17 m·s(-1)), very high-speed distance (VHSR>5.56 m·s(-1)), mean power (Pmean), high metabolic power (HMP>20 W·kg(-1)) and very high metabolic power (VHMP>25 W·kg(-1)). GPS-5 Hz had low error for TD (2.8%) and Pmean (4.5%), while the errors for the other variables ranged from moderate to high (7.5-23.2%). GPS-10 Hz demonstrated a low error for TD (1.9%), HSR (4.7%), Pmean (2.4%) and HMP (4.5%), whereas the errors for VHSR (10.5%) and VHMP (6.2%) were moderate. In general, GPS accuracy increased with a higher sampling rate, but decreased with increasing speed of movement. Both systems could be used for calculating TD and Pmean, but they cannot be used interchangeably. Only GPS-10 Hz demonstrated a sufficient level of accuracy for quantifying distance covered at higher speeds or time spent at very high power. © Georg Thieme Verlag KG Stuttgart · New York.

  7. A Comparative Accuracy Analysis of Classification Methods in Determination of Cultivated Lands with Spot 5 Satellite Imagery

    Science.gov (United States)

    kaya, S.; Alganci, U.; Sertel, E.; Ustundag, B.

    2013-12-01

    A Comparative Accuracy Analysis of Classification Methods in Determination of Cultivated Lands with Spot 5 Satellite Imagery Ugur ALGANCI1, Sinasi KAYA1,2, Elif SERTEL1,2,Berk USTUNDAG3 1 ITU, Center for Satellite Communication and Remote Sensing, 34469, Maslak-Istanbul,Turkey 2 ITU, Department of Geomatics, 34469, Maslak-Istanbul, Turkey 3 ITU, Agricultural and Environmental Informatics Research Center,34469, Maslak-Istanbul,Turkey alganci@itu.edu.tr, kayasina@itu.edu.tr, sertele@itu.edu.tr, berk@berk.tc ABSTRACT Cultivated land determination and their area estimation are important tasks for agricultural management. Derived information is mostly used in agricultural policies and precision agriculture, in specifically; yield estimation, irrigation and fertilization management and farmers declaration verification etc. The use of satellite image in crop type identification and area estimate is common for two decades due to its capability of monitoring large areas, rapid data acquisition and spectral response to crop properties. With launch of high and very high spatial resolution optical satellites in the last decade, such kind of analysis have gained importance as they provide information at big scale. With increasing spatial resolution of satellite images, image classification methods to derive the information form them have become important with increase of the spectral heterogeneity within land objects. In this research, pixel based classification with maximum likelihood algorithm and object based classification with nearest neighbor algorithm were applied to 2012 dated 2.5 m resolution SPOT 5 satellite images in order to investigate the accuracy of these methods in determination of cotton and corn planted lands and their area estimation. Study area was selected in Sanliurfa Province located on Southeastern Turkey that contributes to Turkey's agricultural production in a major way. Classification results were compared in terms of crop type identification using

  8. High-Accuracy Measurements of the Centre of Gravity of Avalanches in Proportional Chambers

    Science.gov (United States)

    Charpak, G.; Jeavons, A.; Sauli, F.; Stubbs, R.

    1973-09-24

    In a multiwire proportional chamber the avalanches occur close to the anode wires. The motion of the positive ions in the large electric fields at the vicinity of the wires induces fast-rising positive pulses on the surrounding electrodes. Different methods have been developed in order to determine the position of the centre of the avalanches. In the method we describe, the centre of gravity of the pulse distribution is measured directly. It seems to lead to an accuracy which is limited only by the stability of the spatial distribution of the avalanches generated by the process being measured.

  9. High-accuracy real-time automatic thresholding for centroid tracker

    Science.gov (United States)

    Zhang, Ye; Wang, Yanjie

    2006-01-01

    Many of the video image trackers today use the centroid as the tracking point. In engineering, a target's centroid is computed from a binary image to reduce the processing time. Hence thresholding of gray level image to binary image is a decisive step in centroid tracking. How to choose the feat thresholds in clutter is still an intractability problem unsolved today. This paper introduces a high-accuracy real-time automatic thresholding method for centroid tracker. It works well for variety types of target tracking in clutter. The core of this method is to get the entire information contained in the histogram, such as the number of the peaks, their height, position and other properties in the histogram. Combine with this histogram analysis; we can get several key pairs of peaks which can include the target and the background around it and use the method of Otsu to get intensity thresholds from them. According to the thresholds, we can gain the binary image and get the centroid from it. To track the target, the paper also suggests subjoining an eyeshot-window, just like our eyes focus on a target, we will not miss it unless it is out of our eyeshot, the impression will help us to extract the target in clutter and track it and we will wait its emergence since it has been covered. To obtain the impression, the paper offers a idea comes from the method of Snakes; it give a great help for us to get a glancing size, so that we can compare the size of the object in the current frame with the former. If the change is little, we consider the object has been tracked well. Otherwise, if the change is bigger than usual, we should analyze the inflection in the histogram to find out what happened to the object. In general, what we have to do is turning the analysis into codes for the tracker to determine a feat threshold. The paper will show the steps in detail. The paper also discusses the hardware architecture which can meet the speed requirement.

  10. How could the replica method improve accuracy of performance assessment of channel coding?

    Science.gov (United States)

    Kabashima, Yoshiyuki

    2009-12-01

    We explore the relation between the techniques of statistical mechanics and information theory for assessing the performance of channel coding. We base our study on a framework developed by Gallager in IEEE Trans. Inform. Theory IT-11, 3 (1965), where the minimum decoding error probability is upper-bounded by an average of a generalized Chernoff's bound over a code ensemble. We show that the resulting bound in the framework can be directly assessed by the replica method, which has been developed in statistical mechanics of disordered systems, whereas in Gallager's original methodology further replacement by another bound utilizing Jensen's inequality is necessary. Our approach associates a seemingly ad hoc restriction with respect to an adjustable parameter for optimizing the bound with a phase transition between two replica symmetric solutions, and can improve the accuracy of performance assessments of general code ensembles including low density parity check codes, although its mathematical justification is still open.

  11. The modified equation approach to the stability and accuracy analysis of finite-difference methods

    Science.gov (United States)

    Warming, R. F.; Hyett, B. J.

    1974-01-01

    The stability and accuracy of finite-difference approximations to simple linear partial differential equations are analyzed by studying the modified partial differential equation. Aside from round-off error, the modified equation represents the actual partial differential equation solved when a numerical solution is computed using a finite-difference equation. The modified equation is derived by first expanding each term of a difference scheme in a Taylor series and then eliminating time derivatives higher than first order by certain algebraic manipulations. The connection between 'heuristic' stability theory based on the modified equation approach and the von Neumann (Fourier) method is established. In addition to the determination of necessary and sufficient conditions for computational stability, a truncated version of the modified equation can be used to gain insight into the nature of both dissipative and dispersive errors.

  12. An investigation of the accuracy of finite difference methods in the solution of linear elasticity problems

    Science.gov (United States)

    Bauld, N. R., Jr.; Goree, J. G.

    1983-01-01

    The accuracy of the finite difference method in the solution of linear elasticity problems that involve either a stress discontinuity or a stress singularity is considered. Solutions to three elasticity problems are discussed in detail: a semi-infinite plane subjected to a uniform load over a portion of its boundary; a bimetallic plate under uniform tensile stress; and a long, midplane symmetric, fiber reinforced laminate subjected to uniform axial strain. Finite difference solutions to the three problems are compared with finite element solutions to corresponding problems. For the first problem a comparison with the exact solution is also made. The finite difference formulations for the three problems are based on second order finite difference formulas that provide for variable spacings in two perpendicular directions. Forward and backward difference formulas are used near boundaries where their use eliminates the need for fictitious grid points.

  13. Advantages of multigrid methods for certifying the accuracy of PDE modeling

    Science.gov (United States)

    Forester, C. K.

    1981-01-01

    Numerical techniques for assessing and certifying the accuracy of the modeling of partial differential equations (PDE) to the user's specifications are analyzed. Examples of the certification process with conventional techniques are summarized for the three dimensional steady state full potential and the two dimensional steady Navier-Stokes equations using fixed grid methods (FG). The advantages of the Full Approximation Storage (FAS) scheme of the multigrid technique of A. Brandt compared with the conventional certification process of modeling PDE are illustrated in one dimension with the transformed potential equation. Inferences are drawn for how MG will improve the certification process of the numerical modeling of two and three dimensional PDE systems. Elements of the error assessment process that are common to FG and MG are analyzed.

  14. An indirect accuracy calibration and uncertainty evaluation method for large scale inner dimensional measurement system

    Science.gov (United States)

    Liu, Bai-Ling; Qu, Xing-Hua

    2013-10-01

    In view of present problem of low accuracy, limited range and low automaticity existing in the large-scale diameter inspection instrument, a precise measuring system (robot) was designed based on laser displacement sensor for large-scale inner diameter in this paper. Since the traditional measuring tool of the robot is expensive and hard to manufacture, an indirect calibration method is proposed. In this study, the system eccentric error is calibrated by ring gauge of laboratory. An experiment, which changes the installed order of located rods to introduce located rods' eccentric error, is designed to test whether the spindle eccentric error remains unchanged. The experiment result shows the variation of spindle's eccentricity after changing rods is within 0.02mm. Due to the spindle is an unchanged part of robot, based on Φ584 series robot calibrated by ring gauge, other series robot can be deduced combining with the length of extended arm.

  15. A new 100-m Digital Elevation Model of the Antarctic Peninsula derived from ASTER Global DEM: methods and accuracy assessment

    Directory of Open Access Journals (Sweden)

    A. J. Cook

    2012-10-01

    Full Text Available A high resolution surface topography Digital Elevation Model (DEM is required to underpin studies of the complex glacier system on the Antarctic Peninsula. A complete DEM with better than 200 m pixel size and high positional and vertical accuracy would enable mapping of all significant glacial basins and provide a dataset for glacier morphology analyses. No currently available DEM meets these specifications. We present a new 100-m DEM of the Antarctic Peninsula (63–70° S, based on ASTER Global Digital Elevation Model (GDEM data. The raw GDEM products are of high-quality on the rugged terrain and coastal-regions of the Antarctic Peninsula and have good geospatial accuracy, but they also contain large errors on ice-covered terrain and we seek to minimise these artefacts. Conventional data correction techniques do not work so we have developed a method that significantly improves the dataset, smoothing the erroneous regions and hence creating a DEM with a pixel size of 100 m that will be suitable for many glaciological applications. We evaluate the new DEM using ICESat-derived elevations, and perform horizontal and vertical accuracy assessments based on GPS positions, SPOT-5 DEMs and the Landsat Image Mosaic of Antarctica (LIMA imagery. The new DEM has a mean elevation difference of −4 m (± 25 m RMSE from ICESat (compared to −13 m mean and ±97 m RMSE for the original ASTER GDEM, and a horizontal error of less than 2 pixels, although elevation accuracies are lower on mountain peaks and steep-sided slopes. The correction method significantly reduces errors on low relief slopes and therefore the DEM can be regarded as suitable for topographical studies such as measuring the geometry and ice flow properties of glaciers on the Antarctic Peninsula. The DEM is available for download from the NSIDC website: http://nsidc.org/data/nsidc-0516.html (Accuracy improvement of T-history method for measuring heat of fusion of various materials

    Energy Technology Data Exchange (ETDEWEB)

    Hiki Hong [KyungHee University (Korea). School of Mechanical and Industrial Systems Engineering; Sun Kuk Kim [KyungHee University (Korea). School of Architecture and Civil Engineering; Yong-Shik Kim [University of Incheon (Korea). Dept. of Architectural Engineering

    2004-06-01

    T-history method, developed for measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and convenience with no sampling process. However, some improper assumptions in the original method, such as using a degree of supercooling as the end of latent heat period and neglecting sensible heat during phase change, can cause significant errors in determining the heat of fusion. We have improved this problem in order to predict better results. The present study shows that the modified T-history method is successfully applied to a variety of PCMs such as paraffin and lauric acid having no or a low degree of supercooling. Also it turned out that selected periods for sensible and latent heat do not significantly affect the accuracy of heat- of-fusion. As a result, the method can provide an appropriate means to assess a newly developed PCM by a cycle test even if a very accurate value cannot be obtained. (author)

  16. Comparison of the accuracy of clinical methods for estimation of fetal weight

    Directory of Open Access Journals (Sweden)

    Haji Esmaeilou M

    2016-01-01

    Full Text Available Estimation of fetal weight (EFW is one of the essential measures for labor and delivery. While the use of ultrasonography for EFW is costly, may not work in some centers. So, to make a non- ultrasound method for EFW is important. This study aimed to compare the accuracy of various clinical methods for EFW with the actual birth weight at term pregnancy. A cross-sectional study conducted on 98 pregnant women who were admitted for delivery with gestational age of 37-42 weeks, singleton pregnancy and cephalic presentation in Imam Khomeini hospital, Ahvaz. The fetal weight was anticipated by a midwife through abdominal palpation (using Leopold's maneuvers, measurements of symphysis-fundal height and abdominal girth, and also three formulas. The results were analyzed using the software SPSS version 20 and SATA11. The actual average birth weight was3242.85±43.37 gr. A significant positive correlation was observed between actual birth weight and clinically estimated weight. Kappa coefficient was > 0.8 when all studied methods were compared with the actual weight. This agreement was greater on abdominal palpation and Risanto’s formula, respectively. In the present study, abdominal palpation and Risanto's formula are more accurate for predicting fetal weight. Since these methods are quick, simple and costeffective for EFW so, they can be a useful alternative instead of routine ultrasonography.

  17. Accuracy of the FAMACHA© method in ewes fed different levels of crude protein

    Directory of Open Access Journals (Sweden)

    Francisco de Assis Fonseca de Macedo

    2014-05-01

    Full Text Available The accuracy of the FAMACHA© method was evaluated on the identification of female sheep fed two levels of crude protein, naturally infected with Haemonchus contortus, by means of the correspondent hematocrit value. Forty-seven female sheep of the breeds Santa Inês (n = 16, Texel (n = 16 and Ile de France (n = 15 aged between eight and twelve months were assigned to two treatments, 12 or 16 % crude protein in the diet. All the animals were wormed thirty days before the first data collections, which were done fortnightly between July 2005 and March 2006. The color of the ocular conjunctiva was individually evaluated according to the precepts of the FAMACHA© method and the hematocrit value of each animal was obtained in laboratory. A correlation of 1:0.7991 was found between the hematocrit values and the classification given by the FAMACHA© method aiming to identify animals with different degrees of anemia. The method was efficient to identify animals to worm, thus representing a support in the identification of animals susceptible to Haemonchus contortus.

  18. [Accuracy of the oscillometric method to measure blood pressure in children

    Science.gov (United States)

    Rego Filho, E A; Mello, S F; Silva, C R; Vituri, D W; Bazoni, E; Gordan, L N

    1999-01-01

    OBJECTIVE: The aim of this study is to analyze the substitution of the standard auscultatory method by the oscillometric blood pressure monitor, independently of the validity of the intraarterial blood pressure measurement. The accuracy of the automatic oscillometric monitor was compared to the auscultatory mercury manometer blood pressure measurement in apparently healthy school age children. METHODS: A device able to perform 3 simultaneous readings are used: one reading by the monitor and the others by two "blind" observers. We studied 72 school age children with the following characteristics: mean age 9.5 (6.1-16.1) and 39 males (54.2%). RESULTS: The difference for the systolic and diastolic blood pressure obtained by the monitor was in average + 6.2 mmHg and + 10.0 mmHg, respectively, when compared to the observer's readings. There was neither a good correlation nor a good agreement between the two observers and the monitor in the blood pressure determination. CONCLUSIONS: We concluded that the substitution of the standard auscultatory method for the non-invasive oscillometric method to measure blood pressure in school age children can not be generally recommended.

  19. SFOL Pulse: A High Accuracy DME Pulse for Alternative Aircraft Position and Navigation

    Directory of Open Access Journals (Sweden)

    Euiho Kim

    2017-09-01

    Full Text Available In the Federal Aviation Administration’s (FAA performance based navigation strategy announced in 2016, the FAA stated that it would retain and expand the Distance Measuring Equipment (DME infrastructure to ensure resilient aircraft navigation capability during the event of a Global Navigation Satellite System (GNSS outage. However, the main drawback of the DME as a GNSS back up system is that it requires a significant expansion of the current DME ground infrastructure due to its poor distance measuring accuracy over 100 m. The paper introduces a method to improve DME distance measuring accuracy by using a new DME pulse shape. The proposed pulse shape was developed by using Genetic Algorithms and is less susceptible to multipath effects so that the ranging error reduces by 36.0–77.3% when compared to the Gaussian and Smoothed Concave Polygon DME pulses, depending on noise environment.

  1. Improving accuracy in the MPM method using a null space filter

    Science.gov (United States)

    Gritton, Chris; Berzins, Martin

    2017-01-01

    The material point method (MPM) has been very successful in providing solutions to many challenging problems involving large deformations. Nevertheless there are some important issues that remain to be resolved with regard to its analysis. One key challenge applies to both MPM and particle-in-cell (PIC) methods and arises from the difference between the number of particles and the number of the nodal grid points to which the particles are mapped. This difference between the number of particles and the number of grid points gives rise to a non-trivial null space of the linear operator that maps particle values onto nodal grid point values. In other words, there are non-zero particle values that when mapped to the grid point nodes result in a zero value there. Moreover, when the nodal values at the grid points are mapped back to particles, part of those particle values may be in that same null space. Given positive mapping weights from particles to nodes such null space values are oscillatory in nature. While this problem has been observed almost since the beginning of PIC methods there are still elements of it that are problematical today as well as methods that transcend it. The null space may be viewed as being connected to the ringing instability identified by Brackbill for PIC methods. It will be shown that it is possible to remove these null space values from the solution using a null space filter. This filter improves the accuracy of the MPM methods using an approach that is based upon a local singular value decomposition (SVD) calculation. This local SVD approach is compared against the global SVD approach previously considered by the authors and to a recent MPM method by Zhang and colleagues.

  2. Proton Affinity Calculations with High Level Methods.

    Science.gov (United States)

    Kolboe, Stein

    2014-08-12

    Proton affinities, stretching from small reference compounds, up to the methylbenzenes and naphthalene and anthracene, have been calculated with high accuracy computational methods, viz. W1BD, G4, G3B3, CBS-QB3, and M06-2X. Computed and the currently accepted reference proton affinities are generally in excellent accord, but there are deviations. The literature value for propene appears to be 6-7 kJ/mol too high. Reported proton affinities for the methylbenzenes seem 4-5 kJ/mol too high. G4 and G3 computations generally give results in good accord with the high level W1BD. Proton affinity values computed with the CBS-QB3 scheme are too low, and the error increases with increasing molecule size, reaching nearly 10 kJ/mol for the xylenes. The functional M06-2X fails markedly for some of the small reference compounds, in particular, for CO and ketene, but calculates methylbenzene proton affinities with high accuracy.

  3. Making high-accuracy null depth measurements for the LBTI exozodi survey

    Science.gov (United States)

    Mennesson, Bertrand; Defrère, Denis; Nowak, Matthias; Hinz, Philip; Millan-Gabet, Rafael; Absil, Olivier; Bailey, Vanessa; Bryden, Geoffrey; Danchi, William; Kennedy, Grant M.; Marion, Lindsay; Roberge, Aki; Serabyn, Eugene; Skemer, Andy J.; Stapelfeldt, Karl; Weinberger, Alycia J.; Wyatt, Mark

    2016-08-01

    The characterization of exozodiacal light emission is both important for the understanding of planetary systems evolution and for the preparation of future space missions aiming to characterize low mass planets in the habitable zone of nearby main sequence stars. The Large Binocular Telescope Interferometer (LBTI) exozodi survey aims at providing a ten-fold improvement over current state of the art, measuring dust emission levels down to a typical accuracy of 12 zodis per star, for a representative ensemble of 30+ high priority targets. Such measurements promise to yield a final accuracy of about 2 zodis on the median exozodi level of the targets sample. Reaching a 1 σ measurement uncertainty of 12 zodis per star corresponds to measuring interferometric cancellation ("null") levels, i.e visibilities at the few 100 ppm uncertainty level. We discuss here the challenges posed by making such high accuracy mid-infrared visibility measurements from the ground and present the methodology we developed for achieving current best levels of 500 ppm or so. We also discuss current limitations and plans for enhanced exozodi observations over the next few years at LBTI.

  4. Accuracy of binding mode prediction with a cascadic stochastic tunneling method.

    Science.gov (United States)

    Fischer, Bernhard; Basili, Serena; Merlitz, Holger; Wenzel, Wolfgang

    2007-07-01

    We investigate the accuracy of the binding modes predicted for 83 complexes of the high-resolution subset of the ASTEX/CCDC receptor-ligand database using the atomistic FlexScreen approach with a simple forcefield-based scoring function. The median RMS deviation between experimental and predicted binding mode was just 0.83 A. Over 80% of the ligands dock within 2 A of the experimental binding mode, for 60 complexes the docking protocol locates the correct binding mode in all of ten independent simulations. Most docking failures arise because (a) the experimental structure clashed in our forcefield and is thus unattainable in the docking process or (b) because the ligand is stabilized by crystal water.

  5. High-accuracy determination of the neutron flux at n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Barbagallo, M.; Colonna, N.; Mastromarco, M.; Meaze, M.; Tagliente, G.; Variale, V. [Sezione di Bari, INFN, Bari (Italy); Guerrero, C.; Andriamonje, S.; Boccone, V.; Brugger, M.; Calviani, M.; Cerutti, F.; Chin, M.; Ferrari, A.; Kadi, Y.; Losito, R.; Versaci, R.; Vlachoudis, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Tsinganis, A. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); National Technical University of Athens (NTUA), Athens (Greece); Tarrio, D.; Duran, I.; Leal-Cidoncha, E.; Paradela, C. [Universidade de Santiago de Compostela, Santiago (Spain); Altstadt, S.; Goebel, K.; Langer, C.; Reifarth, R.; Schmidt, S.; Weigand, M. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (Germany); Andrzejewski, J.; Marganiec, J.; Perkowski, J. [Uniwersytet Lodzki, Lodz (Poland); Audouin, L.; Leong, L.S.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Becares, V.; Cano-Ott, D.; Garcia, A.R.; Gonzalez-Romero, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Becvar, F.; Krticka, M.; Kroll, J.; Valenta, S. [Charles University, Prague (Czech Republic); Belloni, F.; Fraval, K.; Gunsing, F.; Lampoudis, C.; Papaevangelou, T. [Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Berthoumieux, E.; Chiaveri, E. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Billowes, J.; Ware, T.; Wright, T. [University of Manchester, Manchester (United Kingdom); Bosnar, D.; Zugec, P. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Calvino, F.; Cortes, G.; Gomez-Hornillos, M.B.; Riego, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Carrapico, C.; Goncalves, I.F.; Sarmento, R.; Vaz, P. [Universidade Tecnica de Lisboa, Instituto Tecnologico e Nuclear, Instituto Superior Tecnico, Lisboa (Portugal); Cortes-Giraldo, M.A.; Praena, J.; Quesada, J.M.; Sabate-Gilarte, M. [Universidad de Sevilla, Sevilla (Spain); Diakaki, M.; Karadimos, D.; Kokkoris, M.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Domingo-Pardo, C.; Giubrone, G.; Tain, J.L. [CSIC-Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Kivel, N.; Schumann, D.; Steinegger, P. [Paul Scherrer Institut, Villigen PSI (Switzerland); Dzysiuk, N.; Mastinu, P.F. [Laboratori Nazionali di Legnaro, INFN, Rome (Italy); Eleftheriadis, C.; Manousos, A. [Aristotle University of Thessaloniki, Thessaloniki (Greece); Ganesan, S.; Gurusamy, P.; Saxena, A. [Bhabha Atomic Research Centre (BARC), Mumbai (IN); Griesmayer, E.; Jericha, E.; Leeb, H. [Technische Universitaet Wien, Atominstitut, Wien (AT); Hernandez-Prieto, A. [European Organization for Nuclear Research (CERN), Geneva (CH); Universitat Politecnica de Catalunya, Barcelona (ES); Jenkins, D.G.; Vermeulen, M.J. [University of York, Heslington, York (GB); Kaeppeler, F. [Institut fuer Kernphysik, Karlsruhe Institute of Technology, Campus Nord, Karlsruhe (DE); Koehler, P. [Oak Ridge National Laboratory (ORNL), Oak Ridge (US); Lederer, C. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE); University of Vienna, Faculty of Physics, Vienna (AT); Massimi, C.; Mingrone, F.; Vannini, G. [Universita di Bologna (IT); INFN, Sezione di Bologna, Dipartimento di Fisica, Bologna (IT); Mengoni, A.; Ventura, A. [Agenzia nazionale per le nuove tecnologie, l' energia e lo sviluppo economico sostenibile (ENEA), Bologna (IT); Milazzo, P.M. [Sezione di Trieste, INFN, Trieste (IT); Mirea, M. [Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Mondalaers, W.; Plompen, A.; Schillebeeckx, P. [Institute for Reference Materials and Measurements, European Commission JRC, Geel (BE); Pavlik, A.; Wallner, A. [University of Vienna, Faculty of Physics, Vienna (AT); Rauscher, T. [University of Basel, Department of Physics and Astronomy, Basel (CH); Roman, F. [European Organization for Nuclear Research (CERN), Geneva (CH); Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Rubbia, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Laboratori Nazionali del Gran Sasso dell' INFN, Assergi (AQ) (IT); Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE)

    2013-12-15

    The neutron flux of the n{sub T}OF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the n{sub T}OF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n{sub T}OF. An unexpected anomaly in the neutron-induced fission cross section of {sup 235}U is observed in the energy region between 10 and 30keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties. (orig.)

  6. Navigation Facility for High Accuracy Offline Trajectory and Attitude Estimation in Airborne Applications

    Directory of Open Access Journals (Sweden)

    A. Renga

    2013-01-01

    Full Text Available The paper focuses on a navigation facility, relying on commercial-off-the-shelf (COTS technology, developed to generate high-accuracy attitude and trajectory measurements in postprocessing. Target performance is cm-level positioning with tenth of degree attitude accuracy. The facility is based on the concept of GPS-aided inertial navigation but comprises carrier-phase differential GPS (CDGPS processing and attitude estimation based on multiantenna GPS configurations. Expected applications of the system include: (a performance assessment of integrated navigation systems, developed for general aviation aircraft and medium size unmanned aircraft systems (UAS; (b generation of reference measurements to evaluate the flight performance of airborne sensors (e.g., radar or laser; and (c generation of reference trajectory and attitude for improving imaging quality of airborne remote sensing data. The paper describes system architecture, selected algorithms for data processing and integration, and theoretical performance evaluation. Experimental results are also presented confirming the effectiveness of the implemented approach.

  7. In-depth, high-accuracy proteomics of sea urchin tooth organic matrix

    Directory of Open Access Journals (Sweden)

    Mann Matthias

    2008-12-01

    Full Text Available Abstract Background The organic matrix contained in biominerals plays an important role in regulating mineralization and in determining biomineral properties. However, most components of biomineral matrices remain unknown at present. In sea urchin tooth, which is an important model for developmental biology and biomineralization, only few matrix components have been identified. The recent publication of the Strongylocentrotus purpuratus genome sequence rendered possible not only the identification of genes potentially coding for matrix proteins, but also the direct identification of proteins contained in matrices of skeletal elements by in-depth, high-accuracy proteomic analysis. Results We identified 138 proteins in the matrix of tooth powder. Only 56 of these proteins were previously identified in the matrices of test (shell and spine. Among the novel components was an interesting group of five proteins containing alanine- and proline-rich neutral or basic motifs separated by acidic glycine-rich motifs. In addition, four of the five proteins contained either one or two predicted Kazal protease inhibitor domains. The major components of tooth matrix were however largely identical to the set of spicule matrix proteins and MSP130-related proteins identified in test (shell and spine matrix. Comparison of the matrices of crushed teeth to intact teeth revealed a marked dilution of known intracrystalline matrix proteins and a concomitant increase in some intracellular proteins. Conclusion This report presents the most comprehensive list of sea urchin tooth matrix proteins available at present. The complex mixture of proteins identified may reflect many different aspects of the mineralization process. A comparison between intact tooth matrix, presumably containing odontoblast remnants, and crushed tooth matrix served to differentiate between matrix components and possible contributions of cellular remnants. Because LC-MS/MS-based methods directly

  8. High-Accuracy HLA Type Inference from Whole-Genome Sequencing Data Using Population Reference Graphs.

    Directory of Open Access Journals (Sweden)

    Alexander T Dilthey

    2016-10-01

    Full Text Available Genetic variation at the Human Leucocyte Antigen (HLA genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG framework. First, we construct a PRG for 46 (mostly HLA genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1 and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data. Of 158 alleles tested, we correctly infer 157 alleles (99.4%. We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30-250 CPU hours per sample remain a

  9. High-Accuracy HLA Type Inference from Whole-Genome Sequencing Data Using Population Reference Graphs.

    Science.gov (United States)

    Dilthey, Alexander T; Gourraud, Pierre-Antoine; Mentzer, Alexander J; Cereb, Nezih; Iqbal, Zamin; McVean, Gil

    2016-10-01

    Genetic variation at the Human Leucocyte Antigen (HLA) genes is associated with many autoimmune and infectious disease phenotypes, is an important element of the immunological distinction between self and non-self, and shapes immune epitope repertoires. Determining the allelic state of the HLA genes (HLA typing) as a by-product of standard whole-genome sequencing data would therefore be highly desirable and enable the immunogenetic characterization of samples in currently ongoing population sequencing projects. Extensive hyperpolymorphism and sequence similarity between the HLA genes, however, pose problems for accurate read mapping and make HLA type inference from whole-genome sequencing data a challenging problem. We describe how to address these challenges in a Population Reference Graph (PRG) framework. First, we construct a PRG for 46 (mostly HLA) genes and pseudogenes, their genomic context and their characterized sequence variants, integrating a database of over 10,000 known allele sequences. Second, we present a sequence-to-PRG paired-end read mapping algorithm that enables accurate read mapping for the HLA genes. Third, we infer the most likely pair of underlying alleles at G group resolution from the IMGT/HLA database at each locus, employing a simple likelihood framework. We show that HLA*PRG, our algorithm, outperforms existing methods by a wide margin. We evaluate HLA*PRG on six classical class I and class II HLA genes (HLA-A, -B, -C, -DQA1, -DQB1, -DRB1) and on a set of 14 samples (3 samples with 2 x 100bp, 11 samples with 2 x 250bp Illumina HiSeq data). Of 158 alleles tested, we correctly infer 157 alleles (99.4%). We also identify and re-type two erroneous alleles in the original validation data. We conclude that HLA*PRG for the first time achieves accuracies comparable to gold-standard reference methods from standard whole-genome sequencing data, though high computational demands (currently ~30-250 CPU hours per sample) remain a significant

  10. Adaptive switching frequency buck DC—DC converter with high-accuracy on-chip current sensor

    Science.gov (United States)

    Jinguang, Jiang; Fei, Huang; Zhihui, Xiong

    2015-05-01

    A current-mode PWM buck DC—DC converter is proposed. With the high-accuracy on-chip current sensor, the switching frequency can be selected automatically according to load requirements. This method improves efficiency and obtains an excellent transient response. The high accuracy of the current sensor is achieved by a simple switch technique without an amplifier. This has the direct benefit of reducing power dissipation and die size. Additionally, a novel soft-start circuit is presented to avoid the inrush current at the starting up state. Finally, this DC—DC converter is fabricated with the 0.5 μm standard CMOS process. The chip occupies 3.38 mm2. The accuracy of the proposed current sensor can achieve 99.5% @ 200 mA. Experimental results show that the peak efficiency is 91.8%. The input voltage ranges from 5 to 18 V, while a 2 A load current can be obtained. Project supported by the National Natural Science Foundation of China (No. 41274047), the Natural Science Foundation of Jiangsu Province (No. BK2012639), the Science and Technology Enterprises in Jiangsu Province Technology Innovation Fund (No. BC2012121), and the Changzhou Science and Technology Support (Industrial) Project (No. CE20120074).

  11. Accuracy, resolution, and computational complexity of a discontinuous Galerkin finite element method

    NARCIS (Netherlands)

    Ven, van der H.; Vegt, van der J.J.W.; Cockburn, B.; Karniadakis, G.E.; Shu, C.-W.

    2000-01-01

    This series contains monographs of lecture notes type, lecture course material, and high-quality proceedings on topics described by the term "computational science and engineering". This includes theoretical aspects of scientific computing such as mathematical modeling, optimization methods, discret

  12. Analysis of Robot Accuracy Assessed via its Joint Clearance by Virtual Prototyping Method

    Institute of Scientific and Technical Information of China (English)

    GUO Ling; WANG Li-hong; ZHANG Yu-ru

    2004-01-01

    This paper discusses how joint clearance influences robot end effector positioning accuracy and a robot accuracy analysis approach based on a virtual prototype is proposed. First, a 5-DOF( Degree of freedom) rneurosurgery robot was introduced. Then we built its virtual prototype, made movement planning and measured the manipulator tip accuracy, through which this robot accuracy portrait was obtained. Finally,in order to validate the robot accuracy analysis approach which is based on a virtual prototype, the result was compared with that from a model built by robot forward kinematics and robot differential kinematics.The robot accuracy analysis approach presented in this paper gives a new way to enhance robot design quality, and help to optimize the control and programming of the robot.

  13. Accuracy of Conventional Diagnostic Methods for Identifying Structural Changes in Patients with Focal Epilepsy

    Science.gov (United States)

    Dakaj, Nazim; Kruja, Jera; Jashari, Fisnik; Boshnjaku, Dren; Shatri, Nexhat; Zeqiraj, Kamber

    2016-01-01

    Background: Epilepsy is a neurological disorder characterized by abnormal firing of nerve impulses in the brain. Aim: This study aims to investigate the frequency of appearance of pathological changes in conventional examination methods (electroencephalography–EEG, brain computerized tomography -CT or brain magnetic resonance imaging – MRI) in patients with epilepsy, and relationship between clinical manifestations and localization of changes in CT or MRI. Methods: In this study we have included 110 patients with focal epilepsy who fulfilled the inclusion criteria out of 557 initially diagnosed patients. Detailed clinical examination together with brain imaging (CT and MRI) and electroencephalography examination was performed. We have evaluated the accuracy of each diagnostic method to localize the epileptic focus. Diagnosis of epilepsy was determined by the ILAE (International League Against Epilepsy) criteria of the year 1989, and classification of epileptic seizures was made according to the ILAE classification 2010. Results: Electroencephalography presented changes in 60.9% of patients; brain CT in 42.1%, and MRI in 78% of the patients. The results of our study showed that clinical manifestations were not always conveyed with pathological changes in conventional examining methods performed. Of the total of 79 patients with changes in imaging (8 with changes in CT and 71 in MRI), 79.7% presented a clinical picture compatible with the region in which morphological changes were found, while in 20.3% of patients the presented morphological changes were not aligned with the clinical picture. Conclusion: In patients with epilepsy, conventional examination methods do not always find pathological changes, while clinical manifestations of epilepsy did not always coincide with the location of changes in imaging. Further studies are needed to see if there is clear border between focal and generalized epilepsy. PMID:28077892

  14. Antisense sequencing improves the accuracy and precision of A-to-I editing measurements using the peak height ratio method

    Directory of Open Access Journals (Sweden)

    Rinkevich Frank D

    2012-01-01

    Full Text Available Abstract Background A-to-I RNA editing is found in all phyla of animals and contributes to transcript diversity that may have profound impacts on behavior and physiology. Many transcripts of genes involved in axonal conductance, synaptic transmission and modulation are the targets of A-to-I RNA editing. There are a number of methods to measure the extent of A-to-I RNA editing, but they are generally costly and time consuming. One way to determine the frequency of A-to-I RNA editing is the peak height ratio method, which compares the size of peaks on electropherograms that represent unedited and edited sites. Findings Sequencing of 4 editing sites of the Dα6 nicotinic acetylcholine receptor subunit with an antisense primer (which uses T/C peaks to measure unedited and edited sites, respectively showed very accurate and precise measurements of A-to-I RNA editing. The accuracy and precision were excellent for all editing sites, including those edited with high or low frequencies. The frequency of A-to-I RNA editing was comparable to the editing frequency as measured by clone counting from the same sample. Sequencing these same sites with the sense primer (which uses A/G peaks yielded inaccurate and imprecise measurements. Conclusions We have validated and improved the accuracy and precision of the peak height ratio method to measure the frequency of A-to-I RNA editing, and shown that results are primer specific. Thus, the correct sequencing primer must be utilized for the most dependable data. When compared to other methods used to measure the frequency of A-to-I RNA editing, the major benefits of the peak height ratio are that this method is inexpensive, fast, non-labor intensive and easily adaptable to many laboratory and field settings.

  15. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Directory of Open Access Journals (Sweden)

    Guy Jean-Pierre Schumann

    2016-01-01

    Full Text Available Digital elevation models (DEMs are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  16. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Science.gov (United States)

    Schumann, Guy; Moller, Delwyn; Mentgen, Felix

    2015-12-01

    Digital elevation models (DEMs) are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  17. High-accuracy defect sizing for nozzle attachment welds using asymmetric TOFD

    Energy Technology Data Exchange (ETDEWEB)

    Bloodworth, T. [AEA Technology, Risley (United Kingdom)

    1999-09-01

    Inspection procedures for the detection, characterisation and high-accuracy sizing of defects in nozzle attachment welds in a Swedish BWR have been developed. These welds are set-on nozzle-to-pipe attachment welds between the main recirculation pipe and related piping systems. The nozzles and the main recirculation pipe are made of ferritic steel with austenitic stainless steel cladding on the inner surface. The overall wall thickness of the nozzle is 30 mm. The inspection uses an automated pulse-echo technique for the detection and length sizing of defects. Software for the display of complex geometry ultrasonic data is used to assist in data analysis. An unorthodox automated ultrasonic TOFD technique is used to measure the through-wall height of defects. This technique deploys probes on both the nozzle and main pipe surfaces. The TOFD data for this complex geometry are analysed using the CGTOFD software, to locate the origin of defect edge signals. The Qualification detection criterion for this inspection is the detection of defects 6 mm x 18 mm (height x length) or greater. The required length measurement accuracy is {+-}14 mm and the required through-wall height measurement accuracy is {+-}2.3 mm. This last requirement is very demanding. The inspection procedures for detection and sizing passed Procedure Qualification when measured against the above criteria on an `open` test specimen. Data collection and analysis personnel have subsequently passed Personnel Qualification using `blind` specimens. (Author)

  18. Uncertainty and target accuracy studies for the very high temperature reactor(VHTR) physics parameters.

    Energy Technology Data Exchange (ETDEWEB)

    Taiwo, T. A.; Palmiotti, G.; Aliberti, G.; Salvatores, M.; Kim, T.K.

    2005-09-16

    The potential impact of nuclear data uncertainties on a number of performance parameters (core and fuel cycle) of the prismatic block-type Very High Temperature Reactor (VHTR) has been evaluated and results are presented in this report. An uncertainty analysis has been performed, based on sensitivity theory, which underlines what cross-sections, what energy range and what isotopes are responsible for the most significant uncertainties. In order to give guidelines on priorities for new evaluations or validation experiments, required accuracies on specific nuclear data have been derived, accounting for target accuracies on major design parameters. Results of an extensive analysis indicate only a limited number of relevant parameters do not meet the target accuracies assumed in this work; this does not imply that the existing nuclear cross-section data cannot be used for the feasibility and pre-conceptual assessments of the VHTR. However, the results obtained depend on the uncertainty data used, and it is suggested to focus some future evaluation work on the production of consistent, as far as possible complete and user oriented covariance data.

  19. Accuracy assessment of high frequency 3D ultrasound for digital impression-taking of prepared teeth

    Science.gov (United States)

    Heger, Stefan; Vollborn, Thorsten; Tinschert, Joachim; Wolfart, Stefan; Radermacher, Klaus

    2013-03-01

    Silicone based impression-taking of prepared teeth followed by plaster casting is well-established but potentially less reliable, error-prone and inefficient, particularly in combination with emerging techniques like computer aided design and manufacturing (CAD/CAM) of dental prosthesis. Intra-oral optical scanners for digital impression-taking have been introduced but until now some drawbacks still exist. Because optical waves can hardly penetrate liquids or soft-tissues, sub-gingival preparations still need to be uncovered invasively prior to scanning. High frequency ultrasound (HFUS) based micro-scanning has been recently investigated as an alternative to optical intra-oral scanning. Ultrasound is less sensitive against oral fluids and in principal able to penetrate gingiva without invasively exposing of sub-gingival preparations. Nevertheless, spatial resolution as well as digitization accuracy of an ultrasound based micro-scanning system remains a critical parameter because the ultrasound wavelength in water-like media such as gingiva is typically smaller than that of optical waves. In this contribution, the in-vitro accuracy of ultrasound based micro-scanning for tooth geometry reconstruction is being investigated and compared to its extra-oral optical counterpart. In order to increase the spatial resolution of the system, 2nd harmonic frequencies from a mechanically driven focused single element transducer were separated and corresponding 3D surface models were calculated for both fundamentals and 2nd harmonics. Measurements on phantoms, model teeth and human teeth were carried out for evaluation of spatial resolution and surface detection accuracy. Comparison of optical and ultrasound digital impression taking indicate that, in terms of accuracy, ultrasound based tooth digitization can be an alternative for optical impression-taking.

  20. Improved Accuracy of the Inherent Shrinkage Method for Fast and More Reliable Welding Distortion Calculations

    Science.gov (United States)

    Mendizabal, A.; González-Díaz, J. B.; San Sebastián, M.; Echeverría, A.

    2016-07-01

    This paper describes the implementation of a simple strategy adopted for the inherent shrinkage method (ISM) to predict welding-induced distortion. This strategy not only makes it possible for the ISM to reach accuracy levels similar to the detailed transient analysis method (considered the most reliable technique for calculating welding distortion) but also significantly reduces the time required for these types of calculations. This strategy is based on the sequential activation of welding blocks to account for welding direction and transient movement of the heat source. As a result, a significant improvement in distortion prediction is achieved. This is demonstrated by experimentally measuring and numerically analyzing distortions in two case studies: a vane segment subassembly of an aero-engine, represented with 3D-solid elements, and a car body component, represented with 3D-shell elements. The proposed strategy proves to be a good alternative for quickly estimating the correct behaviors of large welded components and may have important practical applications in the manufacturing industry.

  1. The accuracy of a method for printing three-dimensional spinal models.

    Directory of Open Access Journals (Sweden)

    Ai-Min Wu

    Full Text Available To study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology research, but the accuracy of the morphology of a 3D printed model has not been determined.Forty-five computed tomography (CT scans of cervical, thoracic and lumbar spines were obtained, and 44 parameters of the cervical spine, 120 parameters of the thoracic spine, and 50 parameters of the lumbar spine were measured. The CT scan data in DICOM format were imported into Mimics software v10.01 for 3D reconstruction, and the data were saved in .STL format and imported to Cura software. After a 3D digital model was formed, it was saved in Gcode format and exported to a 3D printer for printing. After the 3D printed models were obtained, the above-referenced parameters were measured again.Paired t-tests were used to determine the significance, set to P0.800. The other ICC values were 0.600; none were <0.600.In this study, we provide a protocol for printing accurate 3D spinal models for surgeons and researchers. The resulting 3D printed model is inexpensive and easily obtained for spinal fixation research.

  2. Multispectral image compression methods for improvement of both colorimetric and spectral accuracy

    Science.gov (United States)

    Liang, Wei; Zeng, Ping; Xiao, Zhaolin; Xie, Kun

    2016-07-01

    We propose that both colorimetric and spectral distortion in compressed multispectral images can be reduced by a composite model, named OLCP(W)-X (OptimalLeaders_Color clustering-PCA-W weighted-X coding). In the model, first the spectral-colorimetric clustering is designed for sparse equivalent representation by generating spatial basis. Principal component analysis (PCA) is subsequently used in the manipulation of spatial basis for spectral redundancy removal. Then error compensation mechanism is presented to produce predicted difference image, and finally combined with visual characteristic matrix W, and the created image is compressed by traditional multispectral image coding schemes. We introduce four model-based algorithms to explain their validity. The first two algorithms are OLCPWKWS (OLC-PCA-W-KLT-WT-SPIHT) and OLCPKWS, in which Karhunen-Loeve transform, wavelet transform, and set partitioning in hierarchical trees coding are applied for the created image compression. And the latter two methods are OLCPW-JPEG2000-MCT and OLCP-JPEG2000-MCT. Experimental results show that, compared with the corresponding traditional coding, the proposed OLCPW-X schemes can significantly improve the colorimetric accuracy of rebuilding images under various illumination conditions and generally achieve satisfactory peak signal-to-noise ratio under the same compression ratio. And OLCP-X methods could always ensure superior spectrum reconstruction. Furthermore, our model has excellent performance on user interaction.

  3. Discretization Techniques of Height Function Method for Greater Increased Accuracy of Mass Conservation

    Directory of Open Access Journals (Sweden)

    Boonchai LERTNUWAT

    2014-01-01

    Full Text Available A height function method has been used to solve the shape of free surfaces in incompressible viscous flows for hydrodynamics. Three proposed discretization techniques for the height function method are developed with particular attention to the law of mass conservation. The concept of the proposed techniques is to place a control volume on the most appropriate location in any staggered grid system. First, the proposed techniques and the conventional technique are verified with a simple problem whose exact solution is known. Then, all numerical techniques are examined with a more complicated problem to investigate their accuracy. The simulated results of the proposed techniques are compared to those of conventional technique. Finally, it is concluded that (1 the proposed techniques will give better results than the conventional technique if the grid resolution is sufficiently fine, (2 the first proposed technique gives poorer results than the other proposed techniques, and (3 the second proposed technique gives better results than the third proposed technique, but the third proposed technique is easier to apply due to its explicit form of the equation.

  4. Mixed Anti-diffusion Method for High Resolution Schemes

    Institute of Scientific and Technical Information of China (English)

    李荣华; 张威威

    2004-01-01

    In this paper we study a kied of mixed anti-diffusion method for partial differntial equations. Firstly, we use the method to construct some difference schemes for the conservation laws. The schemes are of second order accuracy and are total variation decreasing (TVD). In particular, there are only three knots involved in the schemes. Secondly, we extend the method to construct a few high accuracy difference schemes for elliptic and parabolic equations. Numerical experiments are carried out to illustrate the efficiency of the method.

  5. An adaptive high-order minimum action method

    Science.gov (United States)

    Wan, Xiaoliang

    2011-10-01

    In this work, we present an adaptive high-order minimum action method for dynamical systems perturbed by small noise. We use the hp finite element method to approximate the minimal action path and nonlinear conjugate gradient method to solve the optimization problem given by the Freidlin-Wentzell least action principle. The gradient of the discrete action functional is obtained through the functional derivative and the moving mesh technique is employed to enhance the approximation accuracy. Numerical examples are given to demonstrate the efficiency and accuracy of the proposed numerical method.

  6. A small and high accuracy gyro stabilization electro-optical platform

    Science.gov (United States)

    Qiu, Haitao; Han, Yonggen; Lv, Yanhong

    2008-10-01

    A high accuracy line-of-sight (LOS) Stabilization system based on digital control technology was designed. The current feedback closed-loop system was introduced which uses the CCD graphic and resolver to constitute the position closed-loop and uses the optic fiber gyro to constitute the rate closed-loop. In order to realize zero steady-state error of angular output in counteracting disturbance from carrier, a PII2 (proportional-integral-double integral) control scheme is proposed. The hardware configuration and software system is presented. Experimental results show that the system has perfect dynamic and static performance and the technical requirements were satisfied.

  7. High Accuracy Three-dimensional Simulation of Micro Injection Moulded Parts

    DEFF Research Database (Denmark)

    Tosello, Guido; Costa, F. S.; Hansen, Hans Nørgaard

    2011-01-01

    Micro injection moulding (μIM) is the key replication technology for high precision manufacturing of polymer micro products. Data analysis and simulations on micro-moulding experiments have been conducted during the present validation study. Detailed information about the μIM process was gathered...... and used to establish a reliable simulation methodology suitable for μIM parts. Various Simulation set-up parameters that have been considered in order to improve the simulation accuracy: injection speed profile, melt and mould temperatures, 3D mesh, material rheology, inertia effect and shrinkage...

  8. High-accuracy mass determination of unstable nuclei with a Penning trap mass spectrometer

    CERN Multimedia

    2002-01-01

    The mass of a nucleus is its most fundamental property. A systematic study of nuclear masses as a function of neutron and proton number allows the observation of collective and single-particle effects in nuclear structure. Accurate mass data are the most basic test of nuclear models and are essential for their improvement. This is especially important for the astrophysical study of nuclear synthesis. In order to achieve the required high accuracy, the mass of ions captured in a Penning trap is determined via their cyclotron frequency $ \

  9. High-accuracy alignment based on atmospherical dispersion - technological approaches and solutions for the dual-wavelength transmitter

    Energy Technology Data Exchange (ETDEWEB)

    Burkhard, Boeckem [Institute for Geodesy and Photogrammetry, ETH Zurich (Switzerland)

    1999-07-01

    In the course of the progressive developments of sophisticated geodetic systems utilizing electromagnetic waves in the visible or near IR-range a more detailed knowledge of the propagation medium and coevally solutions of atmospherically induced limitations will become important. An alignment system based on atmospherical dispersion, called a dispersometer, is a metrological solution to the atmospherically induced limitations, in optical alignment and direction observations of high accuracy. In the dispersometer we are using the dual-wavelength method for dispersive air to obtain refraction compensated angle measurements, the detrimental impact of atmospheric turbulence notwithstanding. The principle of the dual-wavelength method utilizes atmospherical dispersion, i.e. the wavelength dependence of the refractive index. The difference angle between two light beams of different wavelengths, which is called the dispersion angle {delta}{beta}, is to first approximation proportional to the refraction angle: {beta}{sub IR} {nu}({beta}{sub blue} - {beta}{sub IR}) = {nu} {delta}{beta}, this equation implies that the dispersion angle has to be measured at least 42 times more accurate than the desired accuracy of the refraction angle for the wavelengths used in the present dispersometer. This required accuracy constitutes one major difficulty for the instrumental performance in applying the dispersion effect. However, the dual-wavelength method can only be successfully used in an optimized transmitter-receiver combination. Beyond the above mentioned resolution requirement for the detector, major difficulties in instrumental realization arise in the availability of a suitable dual-wavelength laser light source, laser light modulation with a very high extinction ratio and coaxial emittance of mono-mode radiation at both wavelengths. Therefore, this paper focuses on the solutions of the dual-wavelength transmitter introducing a new hardware approach and a complete re-design of

  10. An angle encoder for super-high resolution and super-high accuracy using SelfA

    Science.gov (United States)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-06-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 221 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science & Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 233, that is, corresponding to a 0.0015″ signal period after

  11. High-accuracy current sensing circuit with current compensation technique for buck-boost converter

    Science.gov (United States)

    Rao, Yuan; Deng, Wan-Ling; Huang, Jun-Kai

    2015-03-01

    A novel on-chip current sensing circuit with current compensation technique suitable for buck-boost converter is presented in this article. The proposed technique can sense the full-range inductor current with high accuracy and high speed. It is mainly based on matched current mirror and does not require a large proportion of aspect ratio between the powerFET and the senseFET, thus it reduces the complexity of circuit design and the layout mismatch issue without decreasing the power efficiency. The circuit is fabricated with TSMC 0.25 µm 2P5M mixed-signal process. Simulation results show that the buck-boost converter can be operated at 200 kHz to 4 MHz switching frequency with an input voltage from 2.8 to 4.7 V. The output voltage is 3.6 V, and the maximum accuracy for both high and low side sensing current reaches 99% within the load current ranging from 200 to 600 mA.

  12. Emergency positioning system accuracy with infrared LEDs in high-security facilities

    Science.gov (United States)

    Knoch, Sierra N.; Nelson, Charles; Walker, Owens

    2017-05-01

    Instantaneous personnel location presents a challenge in Department of Defense applications where high levels of security restrict real-time tracking of crew members. During emergency situations, command and control requires immediate accountability of all personnel. Current radio frequency (RF) based indoor positioning systems can be unsuitable due to RF leakage and electromagnetic interference with sensitively calibrated machinery on variable platforms like ships, submarines and high-security facilities. Infrared light provide a possible solution to this problem. This paper proposes and evaluates an indoor line-of-sight positioning system that is comprised of IR and high-sensitivity CMOS camera receivers. In this system the movement of the LEDs is captured by the camera, uploaded and analyzed; the highest point of power is located and plotted to create a blueprint of crewmember location. Results provided evaluate accuracy as a function of both wavelength and environmental conditions. Research will further evaluate the accuracy of the LED transmitter and CMOS camera receiver system. Transmissions in both the 780 and 850nm IR are analyzed.

  13. Application of a solvable model to test the accuracy of the time-dependent Hartree-Fock method

    Energy Technology Data Exchange (ETDEWEB)

    Bouayad, N. [Blida Univ. (Algeria). Inst. de Phys.; Zettili, N. [Blida Univ. (Algeria). Inst. de Phys.]|[Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    1996-11-11

    This work deals with the application of a solvable model to study the accuracy of a nuclear many-body approximation method. Using a new exactly solvable model, we carry out here a quantitative test of the accuracy of the time-dependent Hartree-Fock (TDHF) method. The application of the TDHF method to the model reveals that the model is suitable for describing various forms of collective motion: harmonic and anharmonic oscillations as well as rotations. We then show that, by properly quantizing the TDHF results, the TDHF approximation method yields energy spectra that are in very good agreement with their exact counterparts. This work shows that the model offers a rich and comprehensive framework for studying the various aspects of the TDHF method and also for assessing quantitatively its accuracy. (orig.).

  14. Application of a solvable model to test the accuracy of the time-dependent Hartree-Fock method

    Science.gov (United States)

    Bouayad, Nouredine; Zettili, Nouredine

    1996-02-01

    This work deals with the application of a solvable model to study the accuracy of a nuclear many-body approximation method. Using a new exactly solvable model, we carry out here a quantitative test of the accuracy of the time-dependent Hartree-Fock (TDHF) method. The application of the TDHF method to the model reveals that the model is suitable for describing various forms of collective motion: harmonic and anharmonic oscillations as well as rotations. We then show that, by properly quantizing the TDHF results, the TDHF approximation method yields energy spectra that are in very good agreement with their exact counterparts. This work shows that the model offers a rich and comprehensive framework for studying the various aspects of the TDHF method and also for assessing quantitatively its accuracy.

  15. Improving the accuracy of simulation of radiation-reaction effects with implicit Runge-Kutta-Nyström methods.

    Science.gov (United States)

    Elkina, N V; Fedotov, A M; Herzing, C; Ruhl, H

    2014-05-01

    The Landau-Lifshitz equation provides an efficient way to account for the effects of radiation reaction without acquiring the nonphysical solutions typical for the Lorentz-Abraham-Dirac equation. We solve the Landau-Lifshitz equation in its covariant four-vector form in order to control both the energy and momentum of radiating particles. Our study reveals that implicit time-symmetric collocation methods of the Runge-Kutta-Nyström type are superior in accuracy and better at maintaining the mass-shell condition than their explicit counterparts. We carry out an extensive study of numerical accuracy by comparing the analytical and numerical solutions of the Landau-Lifshitz equation. Finally, we present the results of the simulation of particle scattering by a focused laser pulse. Due to radiation reaction, particles are less capable of penetrating into the focal region compared to the case where radiation reaction is neglected. Our results are important for designing forthcoming experiments with high intensity laser fields.

  16. High order Nystrom method for acoustic scattering

    Science.gov (United States)

    Chen, Kun; Yang, Siming; Song, Jiming; Roberts, Ron

    2015-03-01

    While high frequency approximation methods are widely used to solve flaw scattering in ultrasonic nondestructive evaluation, full wave approaches based on integral equations have great potentials due to their high accuracy. In this work, boundary integral equations for acoustic wave scattering are solved using high order Nyström method. Compared with boundary elements method, it features the coincidence of the samples for interpolation basis and quadrature, which makes the far-field interaction free from numerical integration. The singular integral is dealt with using the Duffy transformation, while efficient singularity subtraction techniques are employed to evaluate the near singular integrals. This approach has the ease to go high order so highly accurate results can be obtained with fewer unknowns and faster convergence, and it is also amenable to incorporate fast algorithms like the multi-level fast multi-pole algorithm. The convergence of the approach for different orders of elements and interpolation basis functions is investigated. Numerical results are shown to validate this approach.

  17. The Influence of Internal Structures in Fused Deposition Modeling Method on Dimensional Accuracy of Components

    Directory of Open Access Journals (Sweden)

    Milde Ján

    2016-09-01

    Full Text Available The paper investigates the influence of infill (internal structures of components in the Fused Deposition Modeling (FDM method on dimensional and geometrical accuracy of components. The components in this case were real models of human mandible, which were obtained by Computed Tomography (CT mostly used in medical applications. In the production phase, the device used for manufacturing, was a 3D printer Zortrax M200 based on the FDM technology. In the second phase, the mandibles made by the printer, were digitized using optical scanning device of GOM ATOS Triple Scan II. They were subsequently evaluated in the final phase. The practical part of this article describes the procedure of jaw model modification, the production of components using a 3D printer, the procedure of digitization of printed parts by optical scanning device and the procedure of comparison. The outcome of this article is a comparative analysis of individual printed parts, containing tables with mean deviations for individual printed parts, as well as tables for groups of printed parts with the same infill parameter.

  18. Accuracy of the lattice-Boltzmann method using the Cell processor

    Science.gov (United States)

    Harvey, M. J.; de Fabritiis, G.; Giupponi, G.

    2008-11-01

    Accelerator processors like the new Cell processor are extending the traditional platforms for scientific computation, allowing orders of magnitude more floating-point operations per second (flops) compared to standard central processing units. However, they currently lack double-precision support and support for some IEEE 754 capabilities. In this work, we develop a lattice-Boltzmann (LB) code to run on the Cell processor and test the accuracy of this lattice method on this platform. We run tests for different flow topologies, boundary conditions, and Reynolds numbers in the range Re=6 350 . In one case, simulation results show a reduced mass and momentum conservation compared to an equivalent double-precision LB implementation. All other cases demonstrate the utility of the Cell processor for fluid dynamics simulations. Benchmarks on two Cell-based platforms are performed, the Sony Playstation3 and the QS20/QS21 IBM blade, obtaining a speed-up factor of 7 and 21, respectively, compared to the original PC version of the code, and a conservative sustained performance of 28 gigaflops per single Cell processor. Our results suggest that choice of IEEE 754 rounding mode is possibly as important as double-precision support for this specific scientific application.

  19. Accuracy analysis of the Null-Screen method for the evaluation of flat heliostats

    Science.gov (United States)

    Cebrian-Xochihuila, P.; Huerta-Carranza, O.; Díaz-Uribe, R.

    2016-04-01

    In this work we develop an algorithm to determinate the accuracy of the Null-Screen Method, used for the testing of flat heliostats used as solar concentrators in a central tower configuration. We simulate the image obtained on a CCD camera when an orderly distribution of points are displayed on a Null-Screen perpendicular to the heliostat under test. The deformations present in the heliostat are represented as a cosine function of the position with different periods and amplitudes. As a resolution criterion, a deformation on the mirror can be detected when the differences in position between the spots on the image plane for the deformed surface as compared with those obtained for an ideally flat heliostat are equal to one pixel. For 6.4μm pixel size and 18mm focal length, the minimum deformation we can measure in the heliostat, correspond to amplitude equal a 122μm for a period equal to 1m; this is equivalent to 0.8mrad in slope. This result depends on the particular configuration used during the test and the size of the heliostat.

  20. Spatial Component Position in Total Hip Arthroplasty. Accuracy and repeatability with a new CT method

    Energy Technology Data Exchange (ETDEWEB)

    Olivecrona, H. [Soedersjukhuset, Stockholm (Sweden). Dept. of Hand Surgery; Weidenhielm, L. [Karolinska Hospital, Stockholm (Sweden). Dept. of Orthopedics; Olivecrona, L. [Karolinska Hospital, Stockholm (Sweden). Dept. of Radiology; Noz, M.E. [New York Univ. School of Medicine, NY (United States). Dept. of Radiology; Maguire, G.Q. [Royal Inst. of Tech., Kista (Sweden). Inst. for Microelectronics and Information Technology; Zeleznik, M. P. [Univ. of Utah, Salt Lake City, UT (United States). Dept. of Radiation Oncology; Svensson, L. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Mathematics; Jonson, T. [Eskadern Foeretagsutveckling AB, Goeteborg (Sweden)

    2003-03-01

    Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically.

  1. Extended canonical Monte Carlo methods: Improving accuracy of microcanonical calculations using a reweighting technique

    Science.gov (United States)

    Velazquez, L.; Castro-Palacio, J. C.

    2015-03-01

    Velazquez and Curilef [J. Stat. Mech. (2010) P02002, 10.1088/1742-5468/2010/02/P02002; J. Stat. Mech. (2010) P04026, 10.1088/1742-5468/2010/04/P04026] have proposed a methodology to extend Monte Carlo algorithms that are based on canonical ensemble. According to our previous study, their proposal allows us to overcome slow sampling problems in systems that undergo any type of temperature-driven phase transition. After a comprehensive review about ideas and connections of this framework, we discuss the application of a reweighting technique to improve the accuracy of microcanonical calculations, specifically, the well-known multihistograms method of Ferrenberg and Swendsen [Phys. Rev. Lett. 63, 1195 (1989), 10.1103/PhysRevLett.63.1195]. As an example of application, we reconsider the study of the four-state Potts model on the square lattice L ×L with periodic boundary conditions. This analysis allows us to detect the existence of a very small latent heat per site qL during the occurrence of temperature-driven phase transition of this model, whose size dependence seems to follow a power law qL(L ) ∝(1/L ) z with exponent z ≃0 .26 ±0 .02. Discussed is the compatibility of these results with the continuous character of temperature-driven phase transition when L →+∞ .

  2. Influence of measuring algorithm on shape accuracy in the compensating turning of high gradient thin-wall parts

    Science.gov (United States)

    Wang, Tao; Wang, Guilin; Zhu, Dengchao; Li, Shengyi

    2015-02-01

    In order to meet the requirement of aerodynamics, the infrared domes or windows with conformal and thin-wall structure becomes the development trend of high-speed aircrafts in the future. But these parts usually have low stiffness, the cutting force will change along with the axial position, and it is very difficult to meet the requirement of shape accuracy by single machining. Therefore, on-machine measurement and compensating turning are used to control the shape errors caused by the fluctuation of cutting force and the change of stiffness. In this paper, on the basis of ultra precision diamond lathe, a contact measuring system with five DOFs is developed to achieve on-machine measurement of conformal thin-wall parts with high accuracy. According to high gradient surface, the optimizing algorithm is designed on the distribution of measuring points by using the data screening method. The influence rule of sampling frequency is analyzed on measuring errors, the best sampling frequency is found out based on planning algorithm, the effect of environmental factors and the fitting errors are controlled within lower range, and the measuring accuracy of conformal dome is greatly improved in the process of on-machine measurement. According to MgF2 conformal dome with high gradient, the compensating turning is implemented by using the designed on-machine measuring algorithm. The shape error is less than PV 0.8μm, greatly superior compared with PV 3μm before compensating turning, which verifies the correctness of measuring algorithm.

  3. An automated method for the evaluation of the pointing accuracy of Sun-tracking devices

    Science.gov (United States)

    Baumgartner, Dietmar J.; Pötzi, Werner; Freislich, Heinrich; Strutzmann, Heinz; Veronig, Astrid M.; Rieder, Harald E.

    2017-03-01

    The accuracy of solar radiation measurements, for direct (DIR) and diffuse (DIF) radiation, depends significantly on the precision of the operational Sun-tracking device. Thus, rigid targets for instrument performance and operation have been specified for international monitoring networks, e.g., the Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Program (WCRP). Sun-tracking devices that fulfill these accuracy requirements are available from various instrument manufacturers; however, none of the commercially available systems comprise an automatic accuracy control system allowing platform operators to independently validate the pointing accuracy of Sun-tracking sensors during operation. Here we present KSO-STREAMS (KSO-SunTRackEr Accuracy Monitoring System), a fully automated, system-independent, and cost-effective system for evaluating the pointing accuracy of Sun-tracking devices. We detail the monitoring system setup, its design and specifications, and the results from its application to the Sun-tracking system operated at the Kanzelhöhe Observatory (KSO) Austrian radiation monitoring network (ARAD) site. The results from an evaluation campaign from March to June 2015 show that the tracking accuracy of the device operated at KSO lies within BSRN specifications (i.e., 0.1° tracking accuracy) for the vast majority of observations (99.8 %). The evaluation of manufacturer-specified active-tracking accuracies (0.02°), during periods with direct solar radiation exceeding 300 W m-2, shows that these are satisfied in 72.9 % of observations. Tracking accuracies are highest during clear-sky conditions and on days where prevailing clear-sky conditions are interrupted by frontal movement; in these cases, we obtain the complete fulfillment of BSRN requirements and 76.4 % of observations within manufacturer-specified active-tracking accuracies. Limitations to tracking surveillance arise during overcast conditions and

  4. Cyclic voltammetric current functions determined with a prescribed accuracy by the adaptive Huber method for Abel integral equations.

    Science.gov (United States)

    Bieniasz, Lesław K

    2008-12-15

    Modern electroanalytical applications of cyclic voltammetry require that theoretical current functions be obtainable automatically, efficiently, and with a prescribed accuracy, by computer simulation algorithms. One of the classical simulation approaches relies on formulating and solving relevant integral equations. Numerical solution methods, used for this purpose so far, are nonautomatic and do not provide information about accuracy of the results. The adaptive variant of the Huber method, developed by the present author, can generate theoretical cyclic voltammograms automatically, with a given target accuracy, and more efficiently than the formerly studied patch-adaptive direct simulation method. This is demonstrated using examples of cyclic voltammograms described by the first-kind Abel integral equations. The method is therefore a candidate for automatic integral equation solvers, needed for building a new generation of problem solving environments for electroanalytical chemistry and for widely understood automation of electroanalytical investigations.

  5. Spatial and temporal analysis on the distribution of active radio-frequency identification (RFID) tracking accuracy with the Kriging method.

    Science.gov (United States)

    Liu, Xin; Shannon, Jeremy; Voun, Howard; Truijens, Martijn; Chi, Hung-Lin; Wang, Xiangyu

    2014-10-29

    Radio frequency identification (RFID) technology has already been applied in a number of areas to facilitate the tracking process. However, the insufficient tracking accuracy of RFID is one of the problems that impedes its wider application. Previous studies focus on examining the accuracy of discrete points RFID, thereby leaving the tracking accuracy of the areas between the observed points unpredictable. In this study, spatial and temporal analysis is applied to interpolate the continuous distribution of RFID tracking accuracy based on the Kriging method. An implementation trial has been conducted in the loading and docking area in front of a warehouse to validate this approach. The results show that the weak signal area can be easily identified by the approach developed in the study. The optimum distance between two RFID readers and the effect of the sudden removal of readers are also presented by analysing the spatial and temporal variation of RFID tracking accuracy. This study reveals the correlation between the testing time and the stability of RFID tracking accuracy. Experimental results show that the proposed approach can be used to assist the RFID system setup process to increase tracking accuracy.

  6. Spatial and Temporal Analysis on the Distribution of Active Radio-Frequency Identification (RFID Tracking Accuracy with the Kriging Method

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2014-10-01

    Full Text Available Radio frequency identification (RFID technology has already been applied in a number of areas to facilitate the tracking process. However, the insufficient tracking accuracy of RFID is one of the problems that impedes its wider application. Previous studies focus on examining the accuracy of discrete points RFID, thereby leaving the tracking accuracy of the areas between the observed points unpredictable. In this study, spatial and temporal analysis is applied to interpolate the continuous distribution of RFID tracking accuracy based on the Kriging method. An implementation trial has been conducted in the loading and docking area in front of a warehouse to validate this approach. The results show that the weak signal area can be easily identified by the approach developed in the study. The optimum distance between two RFID readers and the effect of the sudden removal of readers are also presented by analysing the spatial and temporal variation of RFID tracking accuracy. This study reveals the correlation between the testing time and the stability of RFID tracking accuracy. Experimental results show that the proposed approach can be used to assist the RFID system setup process to increase tracking accuracy.

  7. Enhancing the accuracy of the Fowler method for monitoring non-constant work functions

    Science.gov (United States)

    Friedl, R.

    2016-04-01

    The Fowler method is a prominent non-invasive technique to determine the absolute work function of a surface based on the photoelectric effect. The evaluation procedure relies on the correlation of the photocurrent with the incident photon energy hν which is mainly dependent on the surface work function χ. Applying Fowler's theory of the photocurrent, the measurements can be fitted by the theoretical curve near the threshold hν⪆χ yielding the work function χ and a parameter A. The straightforward experimental implementation of the Fowler method is to use several particular photon energies, e.g. via interference filters. However, with a realization like that the restriction hν ≈ χ can easily be violated, especially when the work function of the material is decreasing during the measurements as, for instance, with coating or adsorption processes. This can lead to an overestimation of the evaluated work function value of typically some 0.1 eV, reaching up to more than 0.5 eV in an unfavorable case. A detailed analysis of the Fowler theory now reveals the background of that effect and shows that the fit-parameter A can be used to assess the accuracy of the determined value of χ conveniently during the measurements. Moreover, a scheme is introduced to quantify a potential overestimation and to perform a correction to χ to a certain extent. The issues are demonstrated exemplarily at the monitoring of the work function reduction of a stainless steel sample surface due to caesiation.

  8. High accuracy of family history of melanoma in Danish melanoma cases

    DEFF Research Database (Denmark)

    Wadt, Karin A W; Drzewiecki, Krzysztof T; Gerdes, Anne-Marie

    2015-01-01

    The incidence of melanoma in Denmark has immensely increased over the last 10 years making Denmark a high risk country for melanoma. In the last two decades multiple public campaigns have sought to increase the awareness of melanoma. Family history of melanoma is a known major risk factor...... but previous studies have shown that self-reported family history of melanoma is highly inaccurate. These studies are 15 years old and we wanted to examine if a higher awareness of melanoma has increased the accuracy of self-reported family history of melanoma. We examined the family history of 181 melanoma...... probands who reported 199 cases of melanoma in relatives, of which 135 cases where in first degree relatives. We confirmed the diagnosis of melanoma in 77% of all relatives, and in 83% of first degree relatives. In 181 probands we validated the negative family history of melanoma in 748 first degree...

  9. High Accuracy mass Measurement of the very Short-Lived Halo Nuclide $^{11}$Li

    CERN Multimedia

    Le scornet, G

    2002-01-01

    The archetypal halo nuclide $^{11}$Li has now attracted a wealth of experimental and theoretical attention. The most outstanding property of this nuclide, its extended radius that makes it as big as $^{48}$Ca, is highly dependent on the binding energy of the two neutrons forming the halo. New generation experiments using radioactive beams with elastic proton scattering, knock-out and transfer reactions, together with $\\textit{ab initio}$ calculations require the tightening of the constraint on the binding energy. Good metrology also requires confirmation of the sole existing precision result to guard against a possible systematic deviation (or mistake). We propose a high accuracy mass determintation of $^{11}$Li, a particularly challenging task due to its very short half-life of 8.6 ms, but one perfectly suiting the MISTRAL spectrometer, now commissioned at ISOLDE. We request 15 shifts of beam time.

  10. Arithmetic Accuracy in Children From High- and Low-Income Schools

    Directory of Open Access Journals (Sweden)

    Elida V. Laski

    2016-04-01

    Full Text Available This study investigated income group differences in kindergartners’ and first graders’ (N = 161 arithmetic by examining the link between accuracy and strategy use on simple and complex addition problems. Low-income children were substantially less accurate than high-income children, in terms of both percentage of correctly solved problems and the magnitude of errors, with low-income first graders being less accurate than high-income kindergartners. Higher-income children were more likely to use sophisticated mental strategies than their lower-income peers, who used predominantly inefficient counting or inappropriate strategies. Importantly, this difference in strategies mediated the relation between income group and addition. Examining underlying strategies has implications for understanding income group differences in arithmetic and potential means of remedying it via instruction.

  11. Location accuracy evaluation of lightning location systems using natural lightning flashes recorded by a network of high-speed cameras

    Science.gov (United States)

    Alves, J.; Saraiva, A. C. V.; Campos, L. Z. D. S.; Pinto, O., Jr.; Antunes, L.

    2014-12-01

    This work presents a method for the evaluation of location accuracy of all Lightning Location System (LLS) in operation in southeastern Brazil, using natural cloud-to-ground (CG) lightning flashes. This can be done through a multiple high-speed cameras network (RAMMER network) installed in the Paraiba Valley region - SP - Brazil. The RAMMER network (Automated Multi-camera Network for Monitoring and Study of Lightning) is composed by four high-speed cameras operating at 2,500 frames per second. Three stationary black-and-white (B&W) cameras were situated in the cities of São José dos Campos and Caçapava. A fourth color camera was mobile (installed in a car), but operated in a fixed location during the observation period, within the city of São José dos Campos. The average distance among cameras was 13 kilometers. Each RAMMER sensor position was determined so that the network can observe the same lightning flash from different angles and all recorded videos were GPS (Global Position System) time stamped, allowing comparisons of events between cameras and the LLS. The RAMMER sensor is basically composed by a computer, a Phantom high-speed camera version 9.1 and a GPS unit. The lightning cases analyzed in the present work were observed by at least two cameras, their position was visually triangulated and the results compared with BrasilDAT network, during the summer seasons of 2011/2012 and 2012/2013. The visual triangulation method is presented in details. The calibration procedure showed an accuracy of 9 meters between the accurate GPS position of the object triangulated and the result from the visual triangulation method. Lightning return stroke positions, estimated with the visual triangulation method, were compared with LLS locations. Differences between solutions were not greater than 1.8 km.

  12. Initial development of high-accuracy CFRP panel for DATE5 antenna

    Science.gov (United States)

    Qian, Yuan; Lou, Zheng; Hao, Xufeng; Zhu, Jing; Cheng, Jingquan; Wang, Hairen; Zuo, Yingxi; Yang, Ji

    2016-07-01

    DATE5 antenna, which is a 5m telescope for terahertz exploration, will be sited at Dome A, Antarctica. It is necessary to keep high surface accuracy of the primary reflector panels so that high observing efficiency can be achieved. In antenna field, carbon fiber reinforced composite (CFRP) sandwich panels are widely used as these panels are light in weight, high in strength, low in thermal expansion, and cheap in mass fabrication. In DATE5 project, CFRP panels are important panel candidates. In the design study phase, a CFRP prototype panel of 1-meter size is initially developed for the verification purpose. This paper introduces the material arrangement in the sandwich panel, measured performance of this testing sandwich structure samples, and together with the panel forming process. For anti-icing in the South Pole region, a special CFRP heating film is embedded in the front skin of sandwich panel. The properties of some types of basic building materials are tested. Base on the results, the deformation of prototype panel with different sandwich structures and skin layers are simulated and a best structural concept is selected. The panel mold used is a high accuracy one with a surface rms error of 1.4 μm. Prototype panels are replicated from the mold. Room temperature curing resin is used to reduce the thermal deformation in the resin transfer process. In the curing, vacuum negative pressure technology is also used to increase the volume content of carbon fiber. After the measurement of the three coordinate measure machine (CMM), a prototype CFRP panel of 5.1 μm rms surface error is developed initially.

  13. An Automated Registration Method with High Accuracy for Oblique Stereo Images Based on Complementary Affine Invariant Features%融合互补仿射不变特征的倾斜立体影像高精度自动配准方法

    Institute of Scientific and Technical Information of China (English)

    姚国标; 邓喀中; 张力; 杨化超; 艾海滨

    2013-01-01

    were acquired by using hybrid constraints based on normalized cross correlation measure .② with the purpose of gaining subpixel accuracy ,initial projection matrix was optimized by least square matching ,and then the matching error was compensated according to the optimal projection matrix ,the initial projection matrix was obtained based on covariance matrix and the principal gradient orientation of correspondent affine regions .③ the high accuracy registration was obtained based on the matching result of the second stage and the projection transforma-tion model .Experiments on oblique images taken by ground close-range and unmanned aerial vehicle (UAV) demonstrate the effectiveness of the proposed algorithm .

  14. Axis-Exchanged Compensation and Gait Parameters Analysis for High Accuracy Indoor Pedestrian Dead Reckoning

    Directory of Open Access Journals (Sweden)

    Honghui Zhang

    2015-01-01

    Full Text Available Pedestrian dead reckoning (PDR is an effective way for navigation coupled with GNSS (Global Navigation Satellite System or weak GNSS signal environment like indoor scenario. However, indoor location with an accuracy of 1 to 2 meters determined by PDR based on MEMS-IMU is still very challenging. For one thing, heading estimation is an important problem in PDR because of the singularities. For another thing, walking distance estimation is also a critical problem for pedestrian walking with randomness. Based on the above two problems, this paper proposed axis-exchanged compensation and gait parameters analysis algorithm to improve the navigation accuracy. In detail, an axis-exchanged compensation factored quaternion algorithm is put forward first to overcome the singularities in heading estimation without increasing the amount of computation. Besides, real-time heading is updated by R-adaptive Kalman filter. Moreover, gait parameters analysis algorithm can be divided into two steps: cadence detection and step length estimation. Thus, a method of cadence classification and interval symmetry is proposed to detect the cadence accurately. Furthermore, a step length model adjusted by cadence is established for step length estimation. Compared to the traditional PDR navigation, experimental results showed that the error of navigation reduces 32.6%.

  15. An output amplitude configurable wideband automatic gain control with high gain step accuracy

    Institute of Scientific and Technical Information of China (English)

    何晓丰; 莫太山; 马成炎; 叶甜春

    2012-01-01

    An output amplitude configurable wideband automatic gain control (AGC) with high gain step accuracy for the GNSS receiver is presented.The amplitude of an AGC is configurable in order to cooperate with baseband chips to achieve interference suppression and be compatible with different full range ADCs.And what's more,the gain-boosting technology is introduced and the circuit is improved to increase the step accuracy.A zero,which is composed by the source feedback resistance and the source capacity,is introduced to compensate for the pole.The AGC is fabricated in a 0.18 μm CMOS process.The AGC shows a 62 dB gain control range by 1 dB each step with a gain error of less than 0.2 dB.The AGC provides 3 dB bandwidth larger than 80 MHz and the overall power consumption is less than 1.8 mA,and the die area is 800 × 300μm2.

  16. Accuracy of the high-throughput amplicon sequencing to identify species within the genus Aspergillus.

    Science.gov (United States)

    Lee, Seungeun; Yamamoto, Naomichi

    2015-12-01

    This study characterized the accuracy of high-throughput amplicon sequencing to identify species within the genus Aspergillus. To this end, we sequenced the internal transcribed spacer 1 (ITS1), β-tubulin (BenA), and calmodulin (CaM) gene encoding sequences as DNA markers from eight reference Aspergillus strains with known identities using 300-bp sequencing on the Illumina MiSeq platform, and compared them with the BLASTn outputs. The identifications with the sequences longer than 250 bp were accurate at the section rank, with some ambiguities observed at the species rank due to mostly cross detection of sibling species. Additionally, in silico analysis was performed to predict the identification accuracy for all species in the genus Aspergillus, where 107, 210, and 187 species were predicted to be identifiable down to the species rank based on ITS1, BenA, and CaM, respectively. Finally, air filter samples were analysed to quantify the relative abundances of Aspergillus species in outdoor air. The results were reproducible across biological duplicates both at the species and section ranks, but not strongly correlated between ITS1 and BenA, suggesting the Aspergillus detection can be taxonomically biased depending on the selection of the DNA markers and/or primers.

  17. Real-Time and High-Accuracy Arctangent Computation Using CORDIC and Fast Magnitude Estimation

    Directory of Open Access Journals (Sweden)

    Luca Pilato

    2017-03-01

    Full Text Available This paper presents an improved VLSI (Very Large Scale of Integration architecture for real-time and high-accuracy computation of trigonometric functions with fixed-point arithmetic, particularly arctangent using CORDIC (Coordinate Rotation Digital Computer and fast magnitude estimation. The standard CORDIC implementation suffers of a loss of accuracy when the magnitude of the input vector becomes small. Using a fast magnitude estimator before running the standard algorithm, a pre-processing magnification is implemented, shifting the input coordinates by a proper factor. The entire architecture does not use a multiplier, it uses only shift and add primitives as the original CORDIC, and it does not change the data path precision of the CORDIC core. A bit-true case study is presented showing a reduction of the maximum phase error from 414 LSB (angle error of 0.6355 rad to 4 LSB (angle error of 0.0061 rad, with small overheads of complexity and speed. Implementation of the new architecture in 0.18 µm CMOS technology allows for real-time and low-power processing of CORDIC and arctangent, which are key functions in many embedded DSP systems. The proposed macrocell has been verified by integration in a system-on-chip, called SENSASIP (Sensor Application Specific Instruction-set Processor, for position sensor signal processing in automotive measurement applications.

  18. High Accuracy Mass Measurement of the Dripline Nuclides $^{12,14}$Be

    CERN Multimedia

    2002-01-01

    State-of-the art, three-body nuclear models that describe halo nuclides require the binding energy of the halo neutron(s) as a critical input parameter. In the case of $^{14}$Be, the uncertainty of this quantity is currently far too large (130 keV), inhibiting efforts at detailed theoretical description. A high accuracy, direct mass deterlnination of $^{14}$Be (as well as $^{12}$Be to obtain the two-neutron separation energy) is therefore required. The measurement can be performed with the MISTRAL spectrometer, which is presently the only possible solution due to required accuracy (10 keV) and short half-life (4.5 ms). Having achieved a 5 keV uncertainty for the mass of $^{11}$Li (8.6 ms), MISTRAL has proved the feasibility of such measurements. Since the current ISOLDE production rate of $^{14}$Be is only about 10/s, the installation of a beam cooler is underway in order to improve MISTRAL transmission. The projected improvement of an order of magnitude (in each transverse direction) will make this measureme...

  19. Combined Scintigraphy and Tumor Marker Analysis Predicts Unfavorable Histopathology of Neuroblastic Tumors with High Accuracy.

    Directory of Open Access Journals (Sweden)

    Wolfgang Peter Fendler

    Full Text Available Our aim was to improve the prediction of unfavorable histopathology (UH in neuroblastic tumors through combined imaging and biochemical parameters.123I-MIBG SPECT and MRI was performed before surgical resection or biopsy in 47 consecutive pediatric patients with neuroblastic tumor. Semi-quantitative tumor-to-liver count-rate ratio (TLCRR, MRI tumor size and margins, urine catecholamine and NSE blood levels of neuron specific enolase (NSE were recorded. Accuracy of single and combined variables for prediction of UH was tested by ROC analysis with Bonferroni correction.34 of 47 patients had UH based on the International Neuroblastoma Pathology Classification (INPC. TLCRR and serum NSE both predicted UH with moderate accuracy. Optimal cut-off for TLCRR was 2.0, resulting in 68% sensitivity and 100% specificity (AUC-ROC 0.86, p < 0.001. Optimal cut-off for NSE was 25.8 ng/ml, resulting in 74% sensitivity and 85% specificity (AUC-ROC 0.81, p = 0.001. Combination of TLCRR/NSE criteria reduced false negative findings from 11/9 to only five, with improved sensitivity and specificity of 85% (AUC-ROC 0.85, p < 0.001.Strong 123I-MIBG uptake and high serum level of NSE were each predictive of UH. Combined analysis of both parameters improved the prediction of UH in patients with neuroblastic tumor. MRI parameters and urine catecholamine levels did not predict UH.

  20. High-accuracy same-beam VLBI observations using Shanghai and Urumqi telescopes

    Institute of Scientific and Technical Information of China (English)

    KIKUCHI; Fuyuhiko; KAMATA; Shun’ichi; MATSUMOTO; Koji; HANADA; Hideo

    2009-01-01

    The same-beam VLBI observations of Rstar and Vstar,which were two small satellites of Japanese lunar mission,SELENE,were successfully performed by using Shanghai and Urumqi 25-m telescopes. When the separation angle between Rstar and Vstar was less than 0.1 deg,the differential phase delay of the X-band signals between Rstar and Vstar on Shanghai-Urumqi baseline was obtained with a very small error of 0.15 mm rms,which was reduced by 1-2 order compared with the former VLBI results. When the separation angle was less than 0.56 deg,the differential phase delay of the S-band signals was also obtained with a very small error of several mm rms. The orbit determination for Rstar and Vstar was performed,and the accuracy was improved to a level of several meters by using VLBI and Doppler data. The high-accuracy same-beam differential VLBI technique is very useful in orbit determination for a spacecraft,and will be used in orbit determination for Mars missions of China Yinghuo-1 and Russia Phobos-grunt.

  1. High-accuracy same-beam VLBI observations using Shanghai and Urumqi telescopes

    Institute of Scientific and Technical Information of China (English)

    LIU QingHui; PING JingSong; FAN QingYuan; XIA Bo; AN Tao; QIAN ZhiHan; YANG WenJun; ZHANG Hua; WANG Zhen; WANG Na; SHI Xian; KIKUCHI Fuyuhiko; HUANG Qian; KAMATA Shun'ichi; MATSUMOTO Koji; HANADA Hideo; HONG XiaoYu; YU AiLi

    2009-01-01

    The same-beam VLBI observations of Rstar and Vstar, which were two small satellites of Japanese lunar mission, SELENE, were successfully performed by using Shanghai and Urumqi 25-m telescopes.When the separation angle between Rstar and Vstar was less than 0.1 deg, the differential phase delay of the X-band signals between Rstar and Vstar on Shanghai-Urumqi baseline was obtained with a very small error of 0.15 mm rms, which was reduced by 1-2 order compared with the former VLBI results.When the separation angle was less than 0.56 deg, the differential phase delay of the S-band signals was also obtained with a very small error of several mm rms. The orbit determination for Rstar and Vstar was performed, and the accuracy was improved to a level of several meters by using VLBI and Doppler data. The high-accuracy same-beam differential VLBI technique is very useful in orbit determination for a spacecraft, and will be used in orbit determination for Mars missions of China Yinghuo-1 and Russia Phobos-grunt.

  2. Reducing Systematic Centroid Errors Induced by Fiber Optic Faceplates in Intensified High-Accuracy Star Trackers

    Science.gov (United States)

    Xiong, Kun; Jiang, Jie

    2015-01-01

    Compared with traditional star trackers, intensified high-accuracy star trackers equipped with an image intensifier exhibit overwhelmingly superior dynamic performance. However, the multiple-fiber-optic faceplate structure in the image intensifier complicates the optoelectronic detecting system of star trackers and may cause considerable systematic centroid errors and poor attitude accuracy. All the sources of systematic centroid errors related to fiber optic faceplates (FOFPs) throughout the detection process of the optoelectronic system were analyzed. Based on the general expression of the systematic centroid error deduced in the frequency domain and the FOFP modulation transfer function, an accurate expression that described the systematic centroid error of FOFPs was obtained. Furthermore, reduction of the systematic error between the optical lens and the input FOFP of the intensifier, the one among multiple FOFPs and the one between the output FOFP of the intensifier and the imaging chip of the detecting system were discussed. Two important parametric constraints were acquired from the analysis. The correctness of the analysis on the optoelectronic detecting system was demonstrated through simulation and experiment. PMID:26016920

  3. THE USE OF THE EXPERIMENT PLANNING METHOD TO EVALUATE THE ACCURACY OF FLEXIBLE UNITS IDENTIFICATION

    Directory of Open Access Journals (Sweden)

    O. Y. Yehorov

    2015-10-01

    Full Text Available Purpose. The identification of rolling stock on the railroads is an integral part of many automation systems as trains in general and cars separately. Various information management systems at sorting yards require the operational information about the object while performing the manufacturing operations. The improvement of the determination accuracy of different parameters characterizing the rolling stock, leads to the immediate quality progress in the traffic volumes management. The aim of the paper is to develop a method to estimate the errors of determination the interaxle distance of the flexible units in the control section using the point path-control transducer for future identification of cars and locomotives. Methodology. To achieve this goal the simulation method and experiment planning were used. The simulation model allowing determining the time intervals between the collisions of wheelset of movable units in point path-control transducer on the control section with variable characteristics of identification devices was developed. The values of the time intervals obtained with using the simulation mode were applied in the method of experiment planning to the final target. Findings. The calculated analytical values of the errors of the interaxle distances do not have the significant differences from values obtained using the simulation model. It makes possible to use the received functional dependence to estimate the possible errors in the identification of rolling stock. The results of this work can be used to identify separate flexible units, and trains in general. Originality. The functional dependence of the error of the interaxle distance error from the fixing point of the wheel path-control transducer, the distance between the sensors and the measured distance was derived using a previously conducted research of the factors influencing the error in determining the interaxle distance of the movable units, and developed

  4. ACCURACY ASSESSMENT OF CROWN DELINEATION METHODS FOR THE INDIVIDUAL TREES USING LIDAR DATA

    Directory of Open Access Journals (Sweden)

    K. T. Chang

    2016-06-01

    Full Text Available Forest canopy density and height are used as variables in a number of environmental applications, including the estimation of biomass, forest extent and condition, and biodiversity. The airborne Light Detection and Ranging (LiDAR is very useful to estimate forest canopy parameters according to the generated canopy height models (CHMs. The purpose of this work is to introduce an algorithm to delineate crown parameters, e.g. tree height and crown radii based on the generated rasterized CHMs. And accuracy assessment for the extraction of volumetric parameters of a single tree is also performed via manual measurement using corresponding aerial photo pairs. A LiDAR dataset of a golf course acquired by Leica ALS70-HP is used in this study. Two algorithms, i.e. a traditional one with the subtraction of a digital elevation model (DEM from a digital surface model (DSM, and a pit-free approach are conducted to generate the CHMs firstly. Then two algorithms, a multilevel morphological active-contour (MMAC and a variable window filter (VWF, are implemented and used in this study for individual tree delineation. Finally, experimental results of two automatic estimation methods for individual trees can be evaluated with manually measured stand-level parameters, i.e. tree height and crown diameter. The resulting CHM generated by a simple subtraction is full of empty pixels (called "pits" that will give vital impact on subsequent analysis for individual tree delineation. The experimental results indicated that if more individual trees can be extracted, tree crown shape will became more completely in the CHM data after the pit-free process.

  5. Accuracy Assessment of Crown Delineation Methods for the Individual Trees Using LIDAR Data

    Science.gov (United States)

    Chang, K. T.; Lin, C.; Lin, Y. C.; Liu, J. K.

    2016-06-01

    Forest canopy density and height are used as variables in a number of environmental applications, including the estimation of biomass, forest extent and condition, and biodiversity. The airborne Light Detection and Ranging (LiDAR) is very useful to estimate forest canopy parameters according to the generated canopy height models (CHMs). The purpose of this work is to introduce an algorithm to delineate crown parameters, e.g. tree height and crown radii based on the generated rasterized CHMs. And accuracy assessment for the extraction of volumetric parameters of a single tree is also performed via manual measurement using corresponding aerial photo pairs. A LiDAR dataset of a golf course acquired by Leica ALS70-HP is used in this study. Two algorithms, i.e. a traditional one with the subtraction of a digital elevation model (DEM) from a digital surface model (DSM), and a pit-free approach are conducted to generate the CHMs firstly. Then two algorithms, a multilevel morphological active-contour (MMAC) and a variable window filter (VWF), are implemented and used in this study for individual tree delineation. Finally, experimental results of two automatic estimation methods for individual trees can be evaluated with manually measured stand-level parameters, i.e. tree height and crown diameter. The resulting CHM generated by a simple subtraction is full of empty pixels (called "pits") that will give vital impact on subsequent analysis for individual tree delineation. The experimental results indicated that if more individual trees can be extracted, tree crown shape will became more completely in the CHM data after the pit-free process.

  6. High Accuracy Microwave Frequency Measurement Based on Single-Drive Dual-Parallel Mach-Zehnder Modulator

    DEFF Research Database (Denmark)

    Zhao, Ying; Deng, Lei; Pang, Xiaodan

    2011-01-01

    A novel approach for broadband microwave frequency measurement based on bias manipulation of a dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. A 10-3 relative error verifies a significant accuracy improvement by this method.......A novel approach for broadband microwave frequency measurement based on bias manipulation of a dual-parallel Mach-Zehnder modulator is proposed and experimentally demonstrated. A 10-3 relative error verifies a significant accuracy improvement by this method....

  7. Interethnic differences in the accuracy of anthropometric indicators of obesity in screening for high risk of coronary heart disease

    Science.gov (United States)

    Herrera, VM; Casas, JP; Miranda, JJ; Perel, P; Pichardo, R; González, A; Sanchez, JR; Ferreccio, C; Aguilera, X; Silva, E; Oróstegui, M; Gómez, LF; Chirinos, JA; Medina-Lezama, J; Pérez, CM; Suárez, E; Ortiz, AP; Rosero, L; Schapochnik, N; Ortiz, Z; Ferrante, D; Diaz, M; Bautista, LE

    2009-01-01

    Background Cut points for defining obesity have been derived from mortality data among Whites from Europe and the United States and their accuracy to screen for high risk of coronary heart disease (CHD) in other ethnic groups has been questioned. Objective To compare the accuracy and to define ethnic and gender-specific optimal cut points for body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) when they are used in screening for high risk of CHD in the Latin-American and the US populations. Methods We estimated the accuracy and optimal cut points for BMI, WC and WHR to screen for CHD risk in Latin Americans (n=18 976), non-Hispanic Whites (Whites; n=8956), non-Hispanic Blacks (Blacks; n=5205) and Hispanics (n=5803). High risk of CHD was defined as a 10-year risk ≥20% (Framingham equation). The area under the receiver operator characteristic curve (AUC) and the misclassification-cost term were used to assess accuracy and to identify optimal cut points. Results WHR had the highest AUC in all ethnic groups (from 0.75 to 0.82) and BMI had the lowest (from 0.50 to 0.59). Optimal cut point for BMI was similar across ethnic/gender groups (27 kg/m2). In women, cut points for WC (94 cm) and WHR (0.91) were consistent by ethnicity. In men, cut points for WC and WHR varied significantly with ethnicity: from 91 cm in Latin Americans to 102 cm in Whites, and from 0.94 in Latin Americans to 0.99 in Hispanics, respectively. Conclusion WHR is the most accurate anthropometric indicator to screen for high risk of CHD, whereas BMI is almost uninformative. The same BMI cut point should be used in all men and women. Unique cut points for WC and WHR should be used in all women, but ethnic-specific cut points seem warranted among men. PMID:19238159

  8. High accuracy calculation of the hydrogen negative ion in strong magnetic fields

    Institute of Scientific and Technical Information of China (English)

    Zhao Ji-Jun; Wang Xiao-Feng; Qiao Hao-Xue

    2011-01-01

    Using a full configuration-interaction method with Hylleraas-Gaussian basis function, this paper investigates the 110+, 11(-1)+ and l1(-2)+ states of the hydrogen negative ion in strong magnetic fields. The total energies, electron detachment energies and derivatives of the total energy with respect to the magnetic field are presented as functions of magnetic field over a wide range of field strengths. Compared with the available theoretical data, the accuracy for the energies is enhanced significantly. The field regimes 3 <γ< 4 and 0.02 < 7< 0.05, in which the l1(-l)+ and l1(-2)+states start to become bound, respectively, are also determined based on the calculated electron detachment energies.

  9. High accuracy Primary Reference gas Mixtures for high-impact greenhouse gases

    Science.gov (United States)

    Nieuwenkamp, Gerard; Zalewska, Ewelina; Pearce-Hill, Ruth; Brewer, Paul; Resner, Kate; Mace, Tatiana; Tarhan, Tanil; Zellweger, Christophe; Mohn, Joachim

    2017-04-01

    Climate change, due to increased man-made emissions of greenhouse gases, poses one of the greatest risks to society worldwide. High-impact greenhouse gases (CO2, CH4 and N2O) and indirect drivers for global warming (e.g. CO) are measured by the global monitoring stations for greenhouse gases, operated and organized by the World Meteorological Organization (WMO). Reference gases for the calibration of analyzers have to meet very challenging low level of measurement uncertainty to comply with the Data Quality Objectives (DQOs) set by the WMO. Within the framework of the European Metrology Research Programme (EMRP), a project to improve the metrology for high-impact greenhouse gases was granted (HIGHGAS, June 2014-May 2017). As a result of the HIGHGAS project, primary reference gas mixtures in cylinders for ambient levels of CO2, CH4, N2O and CO in air have been prepared with unprecedented low uncertainties, typically 3-10 times lower than usually previously achieved by the NMIs. To accomplish these low uncertainties in the reference standards, a number of preparation and analysis steps have been studied and improved. The purity analysis of the parent gases had to be performed with lower detection limits than previously achievable. E.g., to achieve an uncertainty of 2•10-9 mol/mol (absolute) on the amount fraction for N2O, the detection limit for the N2O analysis in the parent gases has to be in the sub nmol/mol domain. Results of an OPO-CRDS analyzer set-up in the 5µm wavelength domain, with a 200•10-12 mol/mol detection limit for N2O, will be presented. The adsorption effects of greenhouse gas components at cylinder surfaces are critical, and have been studied for different cylinder passivation techniques. Results of a two-year stability study will be presented. The fit-for-purpose of the reference materials was studied for possible variation on isotopic composition between the reference material and the sample. Measurement results for a suit of CO2 in air

  10. Very Low Power, Low Voltage, High Accuracy, and High Performance Current Mirror

    Institute of Scientific and Technical Information of China (English)

    Hassan Faraji Baghtash; Khalil Monfaredi; Ahmad Ayatollahi

    2011-01-01

    A novel low power and low voltage current mirror with a very low current copy error is presented and the principle of its operation is discussed.In this circuit,the gain boosting regulated cascode scheme is used to improve the output resistance,while using inverter as an amplifier.The simulation results with HSPICE in TSMC 0.18 μm CMOS technology are given,which verify the high performance of the proposed structure.Simulation results show an input resistance of 0.014 Ω and an output resistance of 3 GΩ.The current copy error is favorable as low as 0.002% together with an input (the minimum input voltage of vin,min~ 0.24 V) and an output (the minimum output voltage of vout,min~ 0.16 V) compliances while working with the 1 V power supply and the 50 μA input current.The current copy error is near zero at the input current of 27 μA.It consumes only 76 μW and introduces a very low output offset current of 50 pA.

  11. Three optimized and validated (using accuracy profiles) LC methods for the determination of pentamidine and new analogs in rat plasma.

    Science.gov (United States)

    Hambÿe, S; Stanicki, D; Colet, J-M; Aliouat, E M; Vanden Eynde, J J; Blankert, B

    2011-01-15

    Three novel LC-UV methods for the determination of pentamidine (PTMD) and two of its new analogs in rat plasma are described. The chromatographic conditions (wavelength, acetonitrile percentage in the mobile phase, internal standard) were optimized to have an efficient selectivity. A pre-step of extraction was simultaneously developed for each compound. For PTMD, a solid phase extraction (SPE) with Oasis(®) HLB cartridges was selected, while for the analogs we used protein precipitation with acetonitrile. SPE for PTMD gave excellent results in terms of extraction yield (99.7 ± 2.8) whereas the recoveries for the analogs were not so high but were reproducible as well (64.6 ± 2.6 and 36.8 ± 1.6 for analog 1 and 2, respectively). By means of a recent strategy based on accuracy profiles (β-expectation tolerance interval), the methods were successfully validated. β was fixed at 95% and the acceptability limits at ± 15% as recommended by the FDA. The method was successfully validated for PTMD (29.6-586.54 ng/mL), analog 1 (74.23-742.3 ng/mL) and analog 2 (178.12-890.6 ng/mL). The first concentration level tested was considered as the LLOQ (lower limit of quantification) for PTMD and analog 1 whereas for analog 2, the LLOQ was not the first level tested and was raised to 178.12 ng/mL.

  12. System Accuracy Evaluation of Different Blood Glucose Monitoring Systems Following ISO 15197:2013 by Using Two Different Comparison Methods.

    Science.gov (United States)

    Freckmann, Guido; Link, Manuela; Schmid, Christina; Pleus, Stefan; Baumstark, Annette; Haug, Cornelia

    2015-09-01

    Adherence to established standards (e.g., International Organization for Standardization [ISO] 15197) is important to ensure comparable and sufficient accuracy of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for different SMBG systems available in Europe with three reagent lots each. Test procedures followed the recently published revision ISO 15197:2013. Comparison measurements were performed with a glucose oxidase (YSI 2300 STAT Plus™ glucose analyzer; YSI Inc., Yellow Springs, OH) and a hexokinase (cobas Integra(®) 400 Plus analyzer; Roche Instrument Center, Rotkreuz, Switzerland) method. Compliance with ISO 15197:2013 accuracy criteria was determined by calculating the percentage of results within ±15% or within ±0.83 mmol/L of the comparison measurement results for glucose concentrations at and above or below 5.55 mmol/L, respectively, and by calculating the percentage of results within consensus error grid Zones A and B. Seven systems showed with all three tested lots that 95-100% of the results were within the accuracy limits of ISO 15197:2013 and that 100% of results were within consensus error grid Zones A and B, irrespective of the comparison method used. Regarding results of individual lots, slight differences between the glucose oxidase method and the hexokinase method were found. Accuracy criteria of ISO 15197:2003 (±20% for concentrations ≥4.2 mmol/L and±0.83 mmol/L for concentrations ISO 15197:2013. The results also indicate that the comparison measurement method/system is important, as it may have a considerable impact on accuracy data obtained for a system.

  13. SLSTR: a high accuracy dual scan temperature radiometer for sea and land surface monitoring from space

    Science.gov (United States)

    Coppo, P.; Ricciarelli, B.; Brandani, F.; Delderfield, J.; Ferlet, M.; Mutlow, C.; Munro, G.; Nightingale, T.; Smith, D.; Bianchi, S.; Nicol, P.; Kirschstein, S.; Hennig, T.; Engel, W.; Frerick, J.; Nieke, J.

    2010-10-01

    SLSTR is a high accuracy infrared radiometer which will be embarked in the Earth low-orbit Sentinel 3 operational GMES mission. SLSTR is an improved version of the previous AATSR and ATSR-1/2 instruments which have flown respectively on Envisat and ERS-1/2 ESA missions. SLSTR will provide data continuity with respect to these previous missions but with a substantial improvement due to its higher swaths (750 km in dual view and 1400 km in single view) which should permit global coverage of SST and LST measurements (at 1 km of spatial resolution in IR channels) with daily revisit time, useful for climatological and meteorological applications. Two more SWIR channels and a higher spatial resolution in the VIS/SWIR channels (0.5 km) are also implemented for a better clouds/aerosols screening. Two further additional channels for global scale fire monitoring are present at the same time as the other nominal channels.

  14. Study on Calibration System for Electronic Transformers Based on High-Accuracy PCI Card

    Directory of Open Access Journals (Sweden)

    Mingzhu Zhang

    2013-03-01

    Full Text Available With preliminary applying of Electronic Transformer (ET based on IEC 61850 standards in power grid, the calibrations of tested transformers have attracted extensive research attention. This study proposes a novel Calibration System of ET (CSET based on high-accuracy card. Data acquisition of ET and Standard Trans-former (ST is gotten by optic Ethernet and PCI-4462 data acquisition card, respectively. Meanwhile, the synchronized sampling between ET and ST is completed on the optic/electronic pulse signal of PCI synchronization card. The signals processing and human interface are realized by Labview software. The system proposed in the study is feasible for calibrating Electronic Voltage/Current Transformers (EVT/ECT of different voltage classes. System tests show that the precision of the system can get to 0.2°.

  15. Study on Calibration System for Electronic Transformers Based on High-Accuracy PCI Card

    Directory of Open Access Journals (Sweden)

    Mingzhu Zhang

    2013-05-01

    Full Text Available With preliminary applying of Electronic Transformer (ET based on IEC 61850 standards in power grid, the calibration of tested transformers has attracted extensive research attention. This study proposes a novel Calibration System of ET (CSET based on high-accuracy card. Data acquisition of ET and standard trans-former (ST is gotten by optic Ethernet and PCI-4462 data acquisition card, respectively. Meanwhile, the synchronized sampling between ET and ST is completed on the optic/electronic pulse signal of PCI synchronization card. The signals processing and human interface are realized by Lab view software. The system proposed in the study is feasible for calibrating Electronic Voltage/Current Transformers (EVT/ECT of different voltage classes. System tests show that the precision of the system can get to 0.2°.

  16. High-Accuracy Programmable Timing Generator with Wide-Range Tuning Capability

    Directory of Open Access Journals (Sweden)

    Ting-Li Chu

    2013-01-01

    Full Text Available In this paper, a high-accuracy programmable timing generator with wide-range tuning capability is proposed. With the aid of dual delay-locked loop (DLL, both of the coarse- and fine-tuning mechanisms are operated in precise closed-loop scheme to lessen the effects of the ambient variations. The timing generator can provide sub-gate resolution and instantaneous switching capability. The circuit is implemented and simulated in TSMC 0.18 μm 1P6M technology. The test chip area occupies 1.9 mm2. The reference clock cycle can be divided into 128 bins by interpolation to obtain 14 ps resolution with the clock rate at 550 MHz. The INL and DNL are within −0.21~+0.78 and −0.27~+0.43 LSB, respectively.

  17. Well-posedness of the difference schemes of the high order of accuracy for elliptic equations

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available It is well known the differential equation − u ″ ( t +Au( t =f( t ( −∞high order of accuracy two-step difference schemes generated by an exact difference scheme or by Taylor's decomposition on three points for the approximate solutions of this differential equation. The well-posedness of these difference schemes in the difference analogy of the smooth functions is obtained. The exact almost coercive inequality for solutions in C( τ,E of these difference schemes is established.

  18. High-accuracy measurement of the magnetic moment anomaly of the electron bound in hydrogenlike carbon.

    Science.gov (United States)

    Häffner, H; Beier, T; Hermanspahn, N; Kluge, H J; Quint, W; Stahl, S; Verdú, J; Werth, G

    2000-12-18

    We present a new experimental value for the magnetic moment of the electron bound in hydrogenlike carbon (12C5+): g(exp) = 2.001 041 596 (5). This is the most precise determination of an atomic g(J) factor so far. The experiment was carried out on a single 12C5+ ion stored in a Penning trap. The high accuracy was made possible by spatially separating the induction of spin flips and the analysis of the spin direction. The current theoretical value amounts to g(th) = 2.001 041 591 (7). Together experiment and theory test the bound-state QED contributions to the g(J) factor of a bound electron to a precision of 1%.

  19. Computer-aided diagnosis of breast MRI with high accuracy optical flow estimation

    Science.gov (United States)

    Meyer-Baese, Anke; Barbu, Adrian; Lobbes, Marc; Hoffmann, Sebastian; Burgeth, Bernhard; Kleefeld, Andreas; Meyer-Bäse, Uwe

    2015-05-01

    Non-mass enhancing lesions represent a challenge for the radiological reading. They are not well-defined in both morphology (geometric shape) and kinetics (temporal enhancement) and pose a problem to lesion detection and classification. To enhance the discriminative properties of an automated radiological workflow, the correct preprocessing steps need to be taken. In an usual computer-aided diagnosis (CAD) system, motion compensation plays an important role. To this end, we employ a new high accuracy optical flow based motion compensation algorithm with robustification variants. An automated computer-aided diagnosis system evaluates the atypical behavior of these lesions, and additionally considers the impact of non-rigid motion compensation on a correct diagnosis.

  20. High Accuracy Speed-fed Grating Angular Acceleration Measurement System Based on FPGA

    Directory of Open Access Journals (Sweden)

    Hao Zhao

    2012-09-01

    Full Text Available Shaft angular acceleration is one of the most important parameter of rotary machines, the error of angular acceleration increased when the shaft speed up. For this problem, a new high accuracy angular acceleration measurement system is presented, the principle of measurement is self-regulating the period of speed sampling signal according to the proportion of the shaft speed up. This measurement system combined FPGA and SCM, the speed of shaft is received by the timer of SCM responding the interrupts of FPGA, and then set the parameter of frequency divider in FPGA, so as to make the period of speed sampling consistent with the proportion of the speed up. This measurement system could overcome the error when system speed up according to the experiment.

  1. Efficient 3D frequency response modeling with spectral accuracy by the rapid expansion method

    KAUST Repository

    Chu, Chunlei

    2012-07-01

    Frequency responses of seismic wave propagation can be obtained either by directly solving the frequency domain wave equations or by transforming the time domain wavefields using the Fourier transform. The former approach requires solving systems of linear equations, which becomes progressively difficult to tackle for larger scale models and for higher frequency components. On the contrary, the latter approach can be efficiently implemented using explicit time integration methods in conjunction with running summations as the computation progresses. Commonly used explicit time integration methods correspond to the truncated Taylor series approximations that can cause significant errors for large time steps. The rapid expansion method (REM) uses the Chebyshev expansion and offers an optimal solution to the second-order-in-time wave equations. When applying the Fourier transform to the time domain wavefield solution computed by the REM, we can derive a frequency response modeling formula that has the same form as the original time domain REM equation but with different summation coefficients. In particular, the summation coefficients for the frequency response modeling formula corresponds to the Fourier transform of those for the time domain modeling equation. As a result, we can directly compute frequency responses from the Chebyshev expansion polynomials rather than the time domain wavefield snapshots as do other time domain frequency response modeling methods. When combined with the pseudospectral method in space, this new frequency response modeling method can produce spectrally accurate results with high efficiency. © 2012 Society of Exploration Geophysicists.

  2. High Accuracy Reference Network (HARN), Published in 2000, 1:600 (1in=50ft) scale, Brown County, WI.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This High Accuracy Reference Network (HARN) dataset, published at 1:600 (1in=50ft) scale, was produced all or in part from Field Survey/GPS information as of 2000....

  3. High-accuracy approximation of high-rank derivatives: isotropic finite differences based on lattice-Boltzmann stencils.

    Science.gov (United States)

    Mattila, Keijo Kalervo; Hegele Júnior, Luiz Adolfo; Philippi, Paulo Cesar

    2014-01-01

    We propose isotropic finite differences for high-accuracy approximation of high-rank derivatives. These finite differences are based on direct application of lattice-Boltzmann stencils. The presented finite-difference expressions are valid in any dimension, particularly in two and three dimensions, and any lattice-Boltzmann stencil isotropic enough can be utilized. A theoretical basis for the proposed utilization of lattice-Boltzmann stencils in the approximation of high-rank derivatives is established. In particular, the isotropy and accuracy properties of the proposed approximations are derived directly from this basis. Furthermore, in this formal development, we extend the theory of Hermite polynomial tensors in the case of discrete spaces and present expressions for the discrete inner products between monomials and Hermite polynomial tensors. In addition, we prove an equivalency between two approaches for constructing lattice-Boltzmann stencils. For the numerical verification of the presented finite differences, we introduce 5th-, 6th-, and 8th-order two-dimensional lattice-Boltzmann stencils.

  4. Dynamic Accuracy of GPS Receivers for Use in Health Research: A Novel Method to Assess GPS Accuracy in Real-World Settings

    Science.gov (United States)

    Schipperijn, Jasper; Kerr, Jacqueline; Duncan, Scott; Madsen, Thomas; Klinker, Charlotte Demant; Troelsen, Jens

    2014-01-01

    The emergence of portable global positioning system (GPS) receivers over the last 10 years has provided researchers with a means to objectively assess spatial position in free-living conditions. However, the use of GPS in free-living conditions is not without challenges and the aim of this study was to test the dynamic accuracy of a portable GPS device under real-world environmental conditions, for four modes of transport, and using three data collection intervals. We selected four routes on different bearings, passing through a variation of environmental conditions in the City of Copenhagen, Denmark, to test the dynamic accuracy of the Qstarz BT-Q1000XT GPS device. Each route consisted of a walk, bicycle, and vehicle lane in each direction. The actual width of each walking, cycling, and vehicle lane was digitized as accurately as possible using ultra-high-resolution aerial photographs as background. For each trip, we calculated the percentage that actually fell within the lane polygon, and within the 2.5, 5, and 10 m buffers respectively, as well as the mean and median error in meters. Our results showed that 49.6% of all ≈68,000 GPS points fell within 2.5 m of the expected location, 78.7% fell within 10 m and the median error was 2.9 m. The median error during walking trips was 3.9, 2.0 m for bicycle trips, 1.5 m for bus, and 0.5 m for car. The different area types showed considerable variation in the median error: 0.7 m in open areas, 2.6 m in half-open areas, and 5.2 m in urban canyons. The dynamic spatial accuracy of the tested device is not perfect, but we feel that it is within acceptable limits for larger population studies. Longer recording periods, for a larger population are likely to reduce the potentially negative effects of measurement inaccuracy. Furthermore, special care should be taken when the environment in which the study takes place could compromise the GPS signal. PMID:24653984

  5. Study of high-altitude radar altimeter model accuracy and SITAN performance using HAAFT data

    Energy Technology Data Exchange (ETDEWEB)

    Shieves, T.C.; Callahan, M.W.

    1979-07-01

    Radar altimetry data, inertial navigation data, and scoring data were collected under the HAAFT program by Martin Marietta Corporation for the United States Air Force over several areas in the western United States at altitudes ranging from 3 to 20 km. The study reported here uses the HAAFT data in conjunction with Defense Mapping Agency (DMA) topographic data to evaluate the accuracy of a high-altitude pulsed-radar altimeter model and the resulting performance of the terrain-aided guidance concept SITAN. Previous SITAN flight tests at low altitudes (less than 1500 m AGL) have demonstrated 6-20 m CEP. The high-altitude flight test data analyzed herein show a SITAN CEP of 120 m. The radar altimeter model was required to achieve this performance includes the effects of the internal track loop, AGC loop, antenna beamwidth, and the terrain radar cross section and provided a factor of 6 improvement over simple nadir ground clearance for rough terrain. It is postulated that high-altitude CEP could be reduced to 50 m or less if an altimeter were designed specifically for high-altitude terrain sensing.

  6. TECHNOLOGICAL PROVISION OF ACCURACY AND QUALITY PARAMETERS OF INTRICATE PROFILE PARTS AT HIGH-SPEED MULTI-COORDINATE MACHINING

    Directory of Open Access Journals (Sweden)

    V. K. Sheleg

    2009-01-01

    Full Text Available The paper considers requirements to CAM-systems for provision of high-speed multi-coordinate milling, principles of generation and recommendations on trajectory programming for high-speed machining, influence of vibration and balancing of the technological system on parameters of  the machining accuracy, characteristics of a cutting tool, types of tool coatings that is rather actual for improvement of accuracy and quality of intricate profile parts.

  7. Accuracy assessment of the Precise Point Positioning method applied for surveys and tracking moving objects in GIS environment

    Science.gov (United States)

    Ilieva, Tamara; Gekov, Svetoslav

    2017-04-01

    The Precise Point Positioning (PPP) method gives the users the opportunity to determine point locations using a single GNSS receiver. The accuracy of the determined by PPP point locations is better in comparison to the standard point positioning, due to the precise satellite orbit and clock corrections that are developed and maintained by the International GNSS Service (IGS). The aim of our current research is the accuracy assessment of the PPP method applied for surveys and tracking moving objects in GIS environment. The PPP data is collected by using preliminary developed by us software application that allows different sets of attribute data for the measurements and their accuracy to be used. The results from the PPP measurements are directly compared within the geospatial database to different other sets of terrestrial data - measurements obtained by total stations, real time kinematic and static GNSS.

  8. Evaluating the accuracy of the colorimetric method of determing the concentration of nonionogenic surfactant, with use of thiocyanocobaltammonium

    Energy Technology Data Exchange (ETDEWEB)

    Safiullina, L.A.; Konyukhova, T.Z.; Shtangeyev, A.L.; Tarasova, N.I.

    1981-01-01

    An examination is made of the results of evaluating the accuracy of the colorimetric method of determining the concentration of nonionogenic surfactants (NPAV) and influence on the results of analysis of a number of factors (time from the beginning of making the analysis, method of extraction, admixtures of ions of iron, etc.). A technique is pinpointed for analysis, and sensitivity of the method is established for determining the NPAV with the use of TCCA.

  9. A Simple Sampling Method for Estimating the Accuracy of Large Scale Record Linkage Projects.

    Science.gov (United States)

    Boyd, James H; Guiver, Tenniel; Randall, Sean M; Ferrante, Anna M; Semmens, James B; Anderson, Phil; Dickinson, Teresa

    2016-05-17

    Record linkage techniques allow different data collections to be brought together to provide a wider picture of the health status of individuals. Ensuring high linkage quality is important to guarantee the quality and integrity of research. Current methods for measuring linkage quality typically focus on precision (the proportion of incorrect links), given the difficulty of measuring the proportion of false negatives. The aim of this work is to introduce and evaluate a sampling based method to estimate both precision and recall following record linkage. In the sampling based method, record-pairs from each threshold (including those below the identified cut-off for acceptance) are sampled and clerically reviewed. These results are then applied to the entire set of record-pairs, providing estimates of false positives and false negatives. This method was evaluated on a synthetically generated dataset, where the true match status (which records belonged to the same person) was known. The sampled estimates of linkage quality were relatively close to actual linkage quality metrics calculated for the whole synthetic dataset. The precision and recall measures for seven reviewers were very consistent with little variation in the clerical assessment results (overall agreement using the Fleiss Kappa statistics was 0.601). This method presents as a possible means of accurately estimating matching quality and refining linkages in population level linkage studies. The sampling approach is especially important for large project linkages where the number of record pairs produced may be very large often running into millions.

  10. Accuracy of maximum likelihood and least-squares estimates in the lidar slope method with noisy data.

    Science.gov (United States)

    Eberhard, Wynn L

    2017-04-01

    The maximum likelihood estimator (MLE) is derived for retrieving the extinction coefficient and zero-range intercept in the lidar slope method in the presence of random and independent Gaussian noise. Least-squares fitting, weighted by the inverse of the noise variance, is equivalent to the MLE. Monte Carlo simulations demonstrate that two traditional least-squares fitting schemes, which use different weights, are less accurate. Alternative fitting schemes that have some positive attributes are introduced and evaluated. The principal factors governing accuracy of all these schemes are elucidated. Applying these schemes to data with Poisson rather than Gaussian noise alters accuracy little, even when the signal-to-noise ratio is low. Methods to estimate optimum weighting factors in actual data are presented. Even when the weighting estimates are coarse, retrieval accuracy declines only modestly. Mathematical tools are described for predicting retrieval accuracy. Least-squares fitting with inverse variance weighting has optimum accuracy for retrieval of parameters from single-wavelength lidar measurements when noise, errors, and uncertainties are Gaussian distributed, or close to optimum when only approximately Gaussian.

  11. Presentation accuracy of the web revisited: animation methods in the HTML5 era.

    Science.gov (United States)

    Garaizar, Pablo; Vadillo, Miguel A; López-de-Ipiña, Diego

    2014-01-01

    Using the Web to run behavioural and social experiments quickly and efficiently has become increasingly popular in recent years, but there is some controversy about the suitability of using the Web for these objectives. Several studies have analysed the accuracy and precision of different web technologies in order to determine their limitations. This paper updates the extant evidence about presentation accuracy and precision of the Web and extends the study of the accuracy and precision in the presentation of multimedia stimuli to HTML5-based solutions, which were previously untested. The accuracy and precision in the presentation of visual content in classic web technologies is acceptable for use in online experiments, although some results suggest that these technologies should be used with caution in certain circumstances. Declarative animations based on CSS are the best alternative when animation intervals are above 50 milliseconds. The performance of procedural web technologies based on the HTML5 standard is similar to that of previous web technologies. These technologies are being progressively adopted by the scientific community and have promising futures, which makes their use advisable to utilizing more obsolete technologies.

  12. Accuracy of plant specimen disease severity estimates: concepts, history, methods, ramifications and challenges for the future

    Science.gov (United States)

    Knowledge of the extent of the symptoms of a plant disease, generally referred to as severity, is key to both fundamental and applied aspects of plant pathology. Most commonly, severity is obtained visually and the accuracy of each estimate (closeness to the actual value) by individual raters is par...

  13. Presentation accuracy of the web revisited: animation methods in the HTML5 era.

    Directory of Open Access Journals (Sweden)

    Pablo Garaizar

    Full Text Available Using the Web to run behavioural and social experiments quickly and efficiently has become increasingly popular in recent years, but there is some controversy about the suitability of using the Web for these objectives. Several studies have analysed the accuracy and precision of different web technologies in order to determine their limitations. This paper updates the extant evidence about presentation accuracy and precision of the Web and extends the study of the accuracy and precision in the presentation of multimedia stimuli to HTML5-based solutions, which were previously untested. The accuracy and precision in the presentation of visual content in classic web technologies is acceptable for use in online experiments, although some results suggest that these technologies should be used with caution in certain circumstances. Declarative animations based on CSS are the best alternative when animation intervals are above 50 milliseconds. The performance of procedural web technologies based on the HTML5 standard is similar to that of previous web technologies. These technologies are being progressively adopted by the scientific community and have promising futures, which makes their use advisable to utilizing more obsolete technologies.

  14. Presentation Accuracy of the Web Revisited: Animation Methods in the HTML5 Era

    Science.gov (United States)

    Garaizar, Pablo; Vadillo, Miguel A.; López-de-Ipiña, Diego

    2014-01-01

    Using the Web to run behavioural and social experiments quickly and efficiently has become increasingly popular in recent years, but there is some controversy about the suitability of using the Web for these objectives. Several studies have analysed the accuracy and precision of different web technologies in order to determine their limitations. This paper updates the extant evidence about presentation accuracy and precision of the Web and extends the study of the accuracy and precision in the presentation of multimedia stimuli to HTML5-based solutions, which were previously untested. The accuracy and precision in the presentation of visual content in classic web technologies is acceptable for use in online experiments, although some results suggest that these technologies should be used with caution in certain circumstances. Declarative animations based on CSS are the best alternative when animation intervals are above 50 milliseconds. The performance of procedural web technologies based on the HTML5 standard is similar to that of previous web technologies. These technologies are being progressively adopted by the scientific community and have promising futures, which makes their use advisable to utilizing more obsolete technologies. PMID:25302791

  15. A method to estimate the enthalpy of formation of organic compounds with chemical accuracy

    DEFF Research Database (Denmark)

    Hukkerikar, Amol; Meier, Robert J.; Sin, Gürkan

    2013-01-01

    . The model which is group-contribution (GC) based, estimates gas phase standard enthalpy of formations (ΔfH°gas) of organic compounds. To achieve the chemical accuracy, a systematic property-data-model analysis, which allows efficient use of knowledge of the experimental data of ΔfH°gas and the molecular...

  16. Integrative fitting of absorption line profiles with high accuracy, robustness, and speed

    Science.gov (United States)

    Skrotzki, Julian; Habig, Jan Christoph; Ebert, Volker

    2014-08-01

    The principle of the integrative evaluation of absorption line profiles relies on the numeric integration of absorption line signals to retrieve absorber concentrations, e.g., of trace gases. Thus, it is a fast and robust technique. However, previous implementations of the integrative evaluation principle showed shortcomings in terms of accuracy and the lack of a fit quality indicator. This has motivated the development of an advanced integrative (AI) fitting algorithm. The AI fitting algorithm retains the advantages of previous integrative implementations—robustness and speed—and is able to achieve high accuracy by introduction of a novel iterative fitting process. A comparison of the AI fitting algorithm with the widely used Levenberg-Marquardt (LM) fitting algorithm indicates that the AI algorithm has advantages in terms of robustness due to its independence from appropriately chosen start values for the initialization of the fitting process. In addition, the AI fitting algorithm shows speed advantages typically resulting in a factor of three to four shorter computational times on a standard personal computer. The LM algorithm on the other hand retains advantages in terms of a much higher flexibility, as the AI fitting algorithm is restricted to the evaluation of single absorption lines with precomputed line width. Comparing both fitting algorithms for the specific application of in situ laser hygrometry at 1,370 nm using direct tunable diode laser absorption spectroscopy (TDLAS) suggests that the accuracy of the AI algorithm is equivalent to that of the LM algorithm. For example, a signal-to-noise ratio of 80 and better typically yields a deviation of TDLAS hygrometry at the aerosol and cloud chamber aerosol interactions and dynamics in the atmosphere (AIDA)—a unique large-scale facility to study atmospheric processes. The robustness of the AI fitting algorithm has been validated for typical AIDA conditions encompassing strong transmission fluctuations

  17. A new device for liver cancer biomarker detection with high accuracy

    Directory of Open Access Journals (Sweden)

    Shuaipeng Wang

    2015-06-01

    Full Text Available A novel cantilever array-based bio-sensor was batch-fabricated with IC compatible MEMS technology for precise liver cancer bio-marker detection. A micro-cavity was designed in the free end of the cantilever for local antibody-immobilization, thus adsorption of the cancer biomarker is localized in the micro-cavity, and the adsorption-induced k variation can be dramatically reduced with comparison to that caused by adsorption of the whole lever. The cantilever is pizeoelectrically driven into vibration which is pizeoresistively sensed by Wheatstone bridge. These structural features offer several advantages: high sensitivity, high throughput, high mass detection accuracy, and small volume. In addition, an analytical model has been established to eliminate the effect of adsorption-induced lever stiffness change and has been applied to precise mass detection of cancer biomarker AFP, the detected AFP antigen mass (7.6 pg/ml is quite close to the calculated one (5.5 pg/ml, two orders of magnitude better than the value by the fully antibody-immobilized cantilever sensor. These approaches will promote real application of the cantilever sensors in early diagnosis of cancer.

  18. High Accuracy Decoding of Dynamical Motion from a Large Retinal Population.

    Directory of Open Access Journals (Sweden)

    Olivier Marre

    2015-07-01

    Full Text Available Motion tracking is a challenge the visual system has to solve by reading out the retinal population. It is still unclear how the information from different neurons can be combined together to estimate the position of an object. Here we recorded a large population of ganglion cells in a dense patch of salamander and guinea pig retinas while displaying a bar moving diffusively. We show that the bar's position can be reconstructed from retinal activity with a precision in the hyperacuity regime using a linear decoder acting on 100+ cells. We then took advantage of this unprecedented precision to explore the spatial structure of the retina's population code. The classical view would have suggested that the firing rates of the cells form a moving hill of activity tracking the bar's position. Instead, we found that most ganglion cells in the salamander fired sparsely and idiosyncratically, so that their neural image did not track the bar. Furthermore, ganglion cell activity spanned an area much larger than predicted by their receptive fields, with cells coding for motion far in their surround. As a result, population redundancy was high, and we could find multiple, disjoint subsets of neurons that encoded the trajectory with high precision. This organization allows for diverse collections of ganglion cells to represent high-accuracy motion information in a form easily read out by downstream neural circuits.

  19. Accuracy of recommended sampling and assay methods for the determination of plasma-free and urinary fractionated metanephrines in the diagnosis of pheochromocytoma and paraganglioma: a systematic review.

    Science.gov (United States)

    Därr, Roland; Kuhn, Matthias; Bode, Christoph; Bornstein, Stefan R; Pacak, Karel; Lenders, Jacques W M; Eisenhofer, Graeme

    2017-06-01

    To determine the accuracy of biochemical tests for the diagnosis of pheochromocytoma and paraganglioma. A search of the PubMed database was conducted for English-language articles published between October 1958 and December 2016 on the biochemical diagnosis of pheochromocytoma and paraganglioma using immunoassay methods or high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection for measurement of fractionated metanephrines in 24-h urine collections or plasma-free metanephrines obtained under seated or supine blood sampling conditions. Application of the Standards for Reporting of Diagnostic Studies Accuracy Group criteria yielded 23 suitable articles. Summary receiver operating characteristic analysis revealed sensitivities/specificities of 94/93% and 91/93% for measurement of plasma-free metanephrines and urinary fractionated metanephrines using high-performance liquid chromatography or immunoassay methods, respectively. Partial areas under the curve were 0.947 vs. 0.911. Irrespective of the analytical method, sensitivity was significantly higher for supine compared with seated sampling, 95 vs. 89% (p sampling compared with 24-h urine, 95 vs. 90% (p sampling, seated sampling, and urine. Test accuracy increased linearly from 90 to 93% for 24-h urine at prevalence rates of 0.0-1.0, decreased linearly from 94 to 89% for seated sampling and was constant at 95% for supine conditions. Current tests for the biochemical diagnosis of pheochromocytoma and paraganglioma show excellent diagnostic accuracy. Supine sampling conditions and measurement of plasma-free metanephrines using high-performance liquid chromatography with coulometric/electrochemical or tandem mass spectrometric detection provides the highest accuracy at all prevalence rates.

  20. Model Accuracy Comparison for High Resolution Insar Coherence Statistics Over Urban Areas

    Science.gov (United States)

    Zhang, Yue; Fu, Kun; Sun, Xian; Xu, Guangluan; Wang, Hongqi

    2016-06-01

    The interferometric coherence map derived from the cross-correlation of two complex registered synthetic aperture radar (SAR) images is the reflection of imaged targets. In many applications, it can act as an independent information source, or give additional information complementary to the intensity image. Specially, the statistical properties of the coherence are of great importance in land cover classification, segmentation and change detection. However, compared to the amount of work on the statistical characters of SAR intensity, there are quite fewer researches on interferometric SAR (InSAR) coherence statistics. And to our knowledge, all of the existing work that focuses on InSAR coherence statistics, models the coherence with Gaussian distribution with no discrimination on data resolutions or scene types. But the properties of coherence may be different for different data resolutions and scene types. In this paper, we investigate on the coherence statistics for high resolution data over urban areas, by making a comparison of the accuracy of several typical statistical models. Four typical land classes including buildings, trees, shadow and roads are selected as the representatives of urban areas. Firstly, several regions are selected from the coherence map manually and labelled with their corresponding classes respectively. Then we try to model the statistics of the pixel coherence for each type of region, with different models including Gaussian, Rayleigh, Weibull, Beta and Nakagami. Finally, we evaluate the model accuracy for each type of region. The experiments on TanDEM-X data show that the Beta model has a better performance than other distributions.

  1. The effect of missing marker genotypes on the accuracy of gene-assisted breeding value estimation: a comparison of methods

    NARCIS (Netherlands)

    Mulder, H.A.; Meuwissen, T.H.E.; Calus, M.P.L.; Veerkamp, R.F.

    2010-01-01

    In livestock populations, missing genotypes on a large proportion of the animals is a major problem when implementing geneassisted breeding value estimation for genes with known effect. The objective of this study was to compare different methods to deal with missing genotypes on accuracy of gene-as

  2. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study

    NARCIS (Netherlands)

    Barsingerhorn, A.D.; Boonstra, F.N.; Goossens, H.H.L.M.

    2017-01-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different

  3. Uncertainty in real-time voltage stability assessment methods based on Thevenin equivalent due to PMU’s accuracy

    DEFF Research Database (Denmark)

    Perez, Angel; Møller, Jakob Glarbo; Jóhannsson, Hjörtur;

    2014-01-01

    This article studies the influence of PMU’s accuracy in voltage stability assessment, considering the specific case of Th ́ evenin equivalent based methods that include wide-area information in its calculations. The objective was achieved by producing a set of synthesized PMU measurements from...

  4. Accuracy and standardization of diagnostic methods for the detection of antibodies to citrullinated peptides

    Directory of Open Access Journals (Sweden)

    M. Tampoia

    2011-06-01

    Full Text Available Anti-citrullinated peptide antibodies (ACPA have a very high specificity for rheumatoid arthritis, much more than that of the rheumatoid factor. In addition, ACPA can be found in sera in the pre-clinical phase, are associated with more severe joint destruction and with higher disease activity. In recent years, keeping pace with new knowledge and with progress made in the antigenic composition of tests and in the characterization of immunogenic epitopes, many immunoenzymatic (ELISA methods of second and third generation have been produced and marketed commercially, and their use has spread among clinical laboratories. Today, completely automated methods are also available, which are easy to use and with a higher throughput, rendering the diagnostic utility of testing ever faster and more effective. This review takes into consideration the more important characteristics of the new ACPA-ELISA tests now commercially available, and also considers recent progress in standardizing test results.

  5. Optimization of process parameters for dimensional accuracy in an area-forming rapid prototyping system using the Taguchi method

    Science.gov (United States)

    Chiu, Shih-Hsuan; Chen, Cheng-Chin; Chen, Kun-Ting; Su, Chun-Hao

    2015-03-01

    Rapid prototyping (RP) technologies have been extensively applied to build products in recent decades. The area-forming rapid prototyping is an emerging RP technology with the advantages of a simple procedure with a short processing time. With the expansion in fields of application, the strictness on product quality has also increased. The dimensional accuracy of a product is one of the most critical quality characteristics. In order to improve the dimensional accuracy of a product from an area-forming RP system, this study optimizes the seven factors via the Taguchi method, and the result is verified with an extra sample.

  6. Accuracy of optical scanning methods of the Cerec®3D system in the process of making ceramic inlays

    Directory of Open Access Journals (Sweden)

    Trifković Branka

    2010-01-01

    Full Text Available Background/Aim. One of the results of many years of Cerec® 3D CAD/CAM system technological development is implementation of one intraoral and two extraoral optical scanning methods which, depending on the current indications, are applied in making fixed restorations. The aim of this study was to determine the degree of precision of optical scanning methods by the use of the Cerec®3D CAD/CAM system in the process of making ceramic inlays. Methods. The study was conducted in three experimental groups of inlays prepared using the procedure of three methods of scanning Cerec ®3D system. Ceramic inlays made by conventional methodology were the control group. The accuracy of optical scanning methods of the Cerec®3D system computer aided designcomputer aided manufacturing (CAD/CAM was indirectly examined by measuring a marginal gap size between inlays and demarcation preparation by scanning electron microscope (SEM. Results. The results of the study showed a difference in the accuracy of the existing methods of scanning dental CAD/CAM systems. The highest level of accuracy was achieved by the extraoral optical superficial scanning technique. The value of marginal gap size inlays made with the technique of extraoral optical superficial scanning was 32.97 ± 13.17 μ. Techniques of intraoral optical superficial and extraoral point laser scanning showed a lower level of accuracy (40.29 ± 21.46 μ for inlays of intraoral optical superficial scanning and 99.67 ± 37.25 μ for inlays of extraoral point laser scanning. Conclusion. Optical scanning methods in dental CAM/CAM technologies are precise methods of digitizing the spatial models; application of extraoral optical scanning methods provides the hightest precision.

  7. Experimental methods for phase equilibria at high pressures.

    Science.gov (United States)

    Dohrn, Ralf; Fonseca, José M S; Peper, Stephanie

    2012-01-01

    Knowledge of high-pressure phase equilibria is crucial in many fields, e.g., for the design and optimization of high-pressure chemical and separation processes, carbon capture and storage, hydrate formation, applications of ionic liquids, and geological processes. This review presents the variety of methods to measure phase equilibria at high pressures and, following a classification, discusses the measurement principles, advantages, challenges, and error sources. Examples of application areas are given. A detailed knowledge and understanding of the different methods is fundamental not only for choosing the most suitable method for a certain task but also for the evaluation of experimental data. The discrepancy between the (sometimes low) true accuracy of published experimental data and the (high) accuracy claimed by authors is addressed. Some essential requirements for the generation of valuable experimental results are summarized.

  8. High-resolution CT of nontuberculous mycobacterium infection in adult CF patients: diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    McEvoy, Sinead; Lavelle, Lisa; Kilcoyne, Aoife; McCarthy, Colin; Dodd, Jonathan D. [St. Vincent' s University Hospital, Department of Radiology, Dublin (Ireland); DeJong, Pim A. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Loeve, Martine; Tiddens, Harm A.W.M. [Erasmus MC-Sophia Children' s Hospital, Department of Radiology, Department of Pediatric Pulmonology and Allergology, Rotterdam (Netherlands); McKone, Edward; Gallagher, Charles G. [St. Vincent' s University Hospital, Department of Respiratory Medicine and National Referral Centre for Adult Cystic Fibrosis, Dublin (Ireland)

    2012-12-15

    To determine the diagnostic accuracy of high-resolution computed tomography (HRCT) for the detection of nontuberculous mycobacterium infection (NTM) in adult cystic fibrosis (CF) patients. Twenty-seven CF patients with sputum-culture-proven NTM (NTM+) underwent HRCT. An age, gender and spirometrically matched group of 27 CF patients without NTM (NTM-) was included as controls. Images were randomly and blindly analysed by two readers in consensus and scored using a modified Bhalla scoring system. Significant differences were seen between NTM (+) and NTM (-) patients in the severity of the bronchiectasis subscore [45 % (1.8/4) vs. 35 % (1.4/4), P = 0.029], collapse/consolidation subscore [33 % (1.3/3) vs. 15 % (0.6/3)], tree-in-bud/centrilobular nodules subscore [43 % (1.7/3) vs. 25 % (1.0/3), P = 0.002] and the total CT score [56 % (18.4/33) vs. 46 % (15.2/33), P = 0.002]. Binary logistic regression revealed BMI, peribronchial thickening, collapse/consolidation and tree-in-bud/centrilobular nodules to be predictors of NTM status (R{sup 2} = 0.43). Receiver-operator curve analysis of the regression model showed an area under the curve of 0.89, P < 0.0001. In adults with CF, seven or more bronchopulmonary segments showing tree-in-bud/centrilobular nodules on HRCT is highly suggestive of NTM colonisation. (orig.)

  9. High accuracy jog CD control on OPC pattern by advanced laser writer Sigma7500

    Science.gov (United States)

    Chin, Tomas; Wu, Wen-Bin; Shih, Chiang-Lin

    2008-10-01

    With the progress of mask writer technology, 50 KV electron beam writers always perform with better pattern fidelity and critical dimension (CD) control than traditional laser raster-scan writers because laser spot size is confined by the laser longer wavelength relative to electron beam. As far as Optical Proximity Correction (OPC) pattern fidelity is concerned, critical masks with OPC process have to choose Variable-Shape-Beam (VSB) electron beam writer presently. However, the over-aggressive OPC fragmentation induces data volume abrupt explosion, longer writing time, higher mask cost and even mask quality degradation 1. Micronic Sigma7500 laser writer introduces a novel imaging system combining partial coherent light and DUV spatial light modulation (SLM) to generate a high-quality pattern image 2. The benefit of raster-scan laser writer is high throughput with consistent writing time regardless of pattern geometry, complexity and data size. However, pattern CD accuracy still needs improvement. This study is to evaluate jog CD control capability of Sigma7500 on OPC typical line-and-space test patterns with different orientations of 0°, 90°, 45° and 135°. In addition, mask CD uniformity and OPC jog height linearity will also be demonstrated.

  10. High-Accuracy Ring Laser Gyroscopes: Earth Rotation Rate and Relativistic Effects

    Science.gov (United States)

    Beverini, N.; Di Virgilio, A.; Belfi, J.; Ortolan, A.; Schreiber, K. U.; Gebauer, A.; Klügel, T.

    2016-06-01

    The Gross Ring G is a square ring laser gyroscope, built as a monolithic Zerodur structure with 4 m length on all sides. It has demonstrated that a large ring laser provides a sensitivity high enough to measure the rotational rate of the Earth with a high precision of ΔΩE GINGER project is intending to take this level of sensitivity further and to improve the accuracy and the long-term stability. A monolithic structure similar to the G ring laser is not available for GINGER. Therefore the preliminary goal is the demonstration of the feasibility of a larger gyroscope structure, where the mechanical stability is obtained through an active control of the geometry. A prototype moderate size gyroscope (GP-2) has been set up in Pisa in order to test this active control of the ring geometry, while a second structure (GINGERino) has been installed inside the Gran Sasso underground laboratory in order to investigate the properties of a deep underground laboratory in view of an installation of a future GINGER apparatus. The preliminary data on these two latter instruments are presented.

  11. Fundamental M-dwarf parameters from high-resolution spectra using PHOENIX ACES models: I. Parameter accuracy and benchmark stars

    CERN Document Server

    Passegger, Vera Maria; Reiners, Ansgar

    2016-01-01

    M-dwarf stars are the most numerous stars in the Universe; they span a wide range in mass and are in the focus of ongoing and planned exoplanet surveys. To investigate and understand their physical nature, detailed spectral information and accurate stellar models are needed. We use a new synthetic atmosphere model generation and compare model spectra to observations. To test the model accuracy, we compared the models to four benchmark stars with atmospheric parameters for which independent information from interferometric radius measurements is available. We used $\\chi^2$ -based methods to determine parameters from high-resolution spectroscopic observations. Our synthetic spectra are based on the new PHOENIX grid that uses the ACES description for the equation of state. This is a model generation expected to be especially suitable for the low-temperature atmospheres. We identified suitable spectral tracers of atmospheric parameters and determined the uncertainties in $T_{\\rm eff}$, $\\log{g}$, and [Fe/H] resul...

  12. Methods specification for diagnostic test accuracy studies in fine-needle aspiration cytology: a survey of reporting practice.

    Science.gov (United States)

    Schmidt, Robert L; Factor, Rachel E; Affolter, Kajsa E; Cook, Joshua B; Hall, Brian J; Narra, Krishna K; Witt, Benjamin L; Wilson, Andrew R; Layfield, Lester J

    2012-01-01

    Diagnostic test accuracy (DTA) studies on fine-needle aspiration cytology (FNAC) often show considerable variability in diagnostic accuracy between study centers. Many factors affect the accuracy of FNAC. A complete description of the testing parameters would help make valid comparisons between studies and determine causes of performance variation. We investigated the manner in which test conditions are specified in FNAC DTA studies to determine which parameters are most commonly specified and the frequency with which they are specified and to see whether there is significant variability in reporting practice. We identified 17 frequently reported test parameters and found significant variation in the reporting of these test specifications across studies. On average, studies reported 5 of the 17 items that would be required to specify the test conditions completely. A more complete and standardized reporting of methods, perhaps by means of a checklist, would improve the interpretation of FNAC DTA studies.

  13. Evaluating a Bayesian approach to improve accuracy of individual photographic identification methods using ecological distribution data

    Directory of Open Access Journals (Sweden)

    Richard Stafford

    2011-04-01

    Full Text Available Photographic identification of individual organisms can be possible from natural body markings. Data from photo-ID can be used to estimate important ecological and conservation metrics such as population sizes, home ranges or territories. However, poor quality photographs or less well-studied individuals can result in a non-unique ID, potentially confounding several similar looking individuals. Here we present a Bayesian approach that uses known data about previous sightings of individuals at specific sites as priors to help assess the problems of obtaining a non-unique ID. Using a simulation of individuals with different confidence of correct ID we evaluate the accuracy of Bayesian modified (posterior probabilities. However, in most cases, the accuracy of identification decreases. Although this technique is unsuccessful, it does demonstrate the importance of computer simulations in testing such hypotheses in ecology.

  14. Accuracy of ELISA detection methods for gluten and reference materials: a realistic assessment.

    Science.gov (United States)

    Diaz-Amigo, Carmen; Popping, Bert

    2013-06-19

    The determination of prolamins by ELISA and subsequent conversion of the resulting concentration to gluten content in food appears to be a comparatively simple and straightforward process with which many laboratories have years-long experience. At the end of the process, a value of gluten, expressed in mg/kg or ppm, is obtained. This value often is the basis for the decision if a product can be labeled gluten-free or not. On the basis of currently available scientific information, the accuracy of the obtained values with commonly used commercial ELISA kits has to be questioned. Although recently several multilaboratory studies have been conducted in an attempt to emphasize and ensure the accuracy of the results, data suggest that it was the precision of these assays, not the accuracy, that was confirmed because some of the underlying assumptions for calculating the gluten content lack scientific data support as well as appropriate reference materials for comparison. This paper discusses the issues of gluten determination and quantification with respect to antibody specificity, extraction procedures, reference materials, and their commutability.

  15. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template.

    Science.gov (United States)

    Matta, Ragai-Edward; Bergauer, Bastian; Adler, Werner; Wichmann, Manfred; Nickenig, Hans-Joachim

    2017-06-01

    The use of a surgical template is a well-established method in advanced implantology. In addition to conventional fabrication, computer-aided design and computer-aided manufacturing (CAD/CAM) work-flow provides an opportunity to engineer implant drilling templates via a three-dimensional printer. In order to transfer the virtual planning to the oral situation, a highly accurate surgical guide is needed. The aim of this study was to evaluate the impact of the fabrication method on the three-dimensional accuracy. The same virtual planning based on a scanned plaster model was used to fabricate a conventional thermo-formed and a three-dimensional printed surgical guide for each of 13 patients (single tooth implants). Both templates were acquired individually on the respective plaster model using an optical industrial white-light scanner (ATOS II, GOM mbh, Braunschweig, Germany), and the virtual datasets were superimposed. Using the three-dimensional geometry of the implant sleeve, the deviation between both surgical guides was evaluated. The mean discrepancy of the angle was 3.479° (standard deviation, 1.904°) based on data from 13 patients. Concerning the three-dimensional position of the implant sleeve, the highest deviation was in the Z-axis at 0.594 mm. The mean deviation of the Euclidian distance, dxyz, was 0.864 mm. Although the two different fabrication methods delivered statistically significantly different templates, the deviations ranged within a decimillimeter span. Both methods are appropriate for clinical use. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Assessing the Accuracy of Sentinel-3 SLSTR Sea-Surface Temperature Retrievals Using High Accuracy Infrared Radiiometers on Ships of Opportunity

    Science.gov (United States)

    Minnett, P. J.; Izaguirre, M. A.; Szcszodrak, M.; Williams, E.; Reynolds, R. M.

    2015-12-01

    The assessment of errors and uncertainties in satellite-derived SSTs can be achieved by comparisons with independent measurements of skin SST of high accuracy. Such validation measurements are provided by well-calibrated infrared radiometers mounted on ships. The second generation of Marine-Atmospheric Emitted Radiance Interferometers (M-AERIs) have recently been developed and two are now deployed on cruise ships of Royal Caribbean Cruise Lines that operate in the Caribbean Sea, North Atlantic and Mediterranean Sea. In addition, two Infrared SST Autonomous Radiometers (ISARs) are mounted alternately on a vehicle transporter of NYK Lines that crosses the Pacific Ocean between Japan and the USA. Both M-AERIs and ISARs are self-calibrating radiometers having two internal blackbody cavities to provide at-sea calibration of the measured radiances, and the accuracy of the internal calibration is periodically determined by measurements of a NIST-traceable blackbody cavity in the laboratory. This provides SI-traceability for the at-sea measurements. It is anticipated that these sensors will be deployed during the next several years and will be available for the validation of the SLSTRs on Sentinel-3a and -3b.

  17. Accuracy of the field triage protocol in selecting severely injured patients after high energy trauma.

    Science.gov (United States)

    van Laarhoven, J J E M; Lansink, K W W; van Heijl, M; Lichtveld, R A; Leenen, L P H

    2014-05-01

    For optimal treatment of trauma patients it is of great importance to identify patients who are at risk for severe injuries. The Dutch field triage protocol for trauma patients, the LPA (National Protocol of Ambulance Services), is designed to get the right patient, in the right time, to the right hospital. Purpose of this study was to determine diagnostic accuracy and compliance of this triage protocol. Triage criteria were categorised into physiological condition (P), mechanism of trauma (M) and injury type (I). A retrospective analysis of prospectively collected data of all high-energy trauma patients from 2008 to 2011 in the region Central Netherlands is performed. Diagnostic parameters (sensitivity, specificity, negative predictive value, positive predictive value) of the field triage protocol for selecting severely injured patients were calculated including rates of under- and overtriage. Undertriage was defined as the proportion of severely injured patients (Injury Severity Score (ISS)≥16) who were transported to a level two or three trauma care centre. Overtriage was defined as the proportion of non-severely injured patients (ISSprotocol was 89.1% (95% confidence interval (CI) 84.4-92.6) and 60.5% (95% CI 57.9-63.1), respectively. The overall rate of undertriage was 10.9% (95%CI 7.4-15.7) and the overall rate of overtriage was 39.5% (95%CI 36.9-42.1). These rates were 16.5% and 37.7%, respectively for patients with M+I-P-. Compliance to the triage protocol for patients with M+I-P- was 78.7%. Furthermore, compliance in patients with either a positive I+ or positive P+ was 91.2%. The overall rate of undertriage (10.8%) was mainly influenced by a high rate of undertriage in the group of patients with only a positive mechanism criterion, therefore showing low diagnostic accuracy in selecting severely injured patients. As a consequence these patients with severe injury are undetected using the current triage protocol. As it has been shown that severely injured

  18. Analysis of reliability, accuracy, sensitivity and predictive value of a subjective method to classify facial pattern in adults

    Science.gov (United States)

    Queiroz, Gilberto Vilanova; Rino, José; de Paiva, João Batista; Capelozza, Leopoldino

    2016-01-01

    ABSTRACT Introduction: Craniofacial pattern diagnosis is vital in Orthodontics, as it influences decision-making regarding treatment options and prognosis. Capelozza Filho proposed a subjective method for facial classification comprising five patterns: I, II, III, Long Face and Short Face. Objective: To investigate the accuracy of a subjective classification method of facial patterns applied to adults. Methods: A sample consisting of 52 adults was used for this study. Frontal and lateral view photographs were taken with subjects at rest position, including frontal smile. Lateral cephalometric radiographs were organized in a PowerPoint® presentation and submitted to 20 raters. Method performance was assessed by examining reproducibility with Kappa test and calculating accuracy, sensitivity and positive predictive values, for which 70% was set as critical value. The gold standard of the classification was personally set by the author of the method. Results: Reproducibility was considered moderate (Kappa = 0.501); while accuracy, sensitivity and positive predictive values yielded similar results, but below 70%. Conclusions: The subjective method of facial classification employed in the present study still needs to have its morphological criteria improved in order to be used to discriminate the five facial patterns. PMID:28125141

  19. Cost-effective improvements of a rotating platform by integration of a high-accuracy inclinometer and encoders for attitude evaluation

    Science.gov (United States)

    Wen, Chenyang; He, Shengyang; Bu, Changgen; Hu, Peida

    2017-01-01

    Attitude heading reference systems (AHRSs) based on micro-electromechanical system (MEMS) inertial sensors are widely used because of their low cost, light weight, and low power. However, low-cost AHRSs suffer from large inertial sensor errors. Therefore, experimental performance evaluation of MEMS-based AHRSs after system implementation is necessary. High-accuracy turntables can be used to verify the performance of MEMS-based AHRSs indoors, but they are expensive and unsuitable for outdoor tests. This study developed a low-cost two-axis rotating platform for indoor and outdoor attitude determination. A high-accuracy inclinometer and encoders were integrated into the platform to improve the achievable attitude test accuracy. An attitude error compensation method was proposed to calibrate the initial attitude errors caused by the movements and misalignment angles of the platform. The proposed attitude error determination method was examined through rotating experiments, which showed that the standard deviations of the pitch and roll errors were 0.050° and 0.090°, respectively. The pitch and roll errors both decreased to 0.024° when the proposed attitude error determination method was used. This decrease validates the effectiveness of the compensation method. Experimental results demonstrated that the integration of the inclinometer and encoders improved the performance of the low-cost, two-axis, rotating platform in terms of attitude accuracy.

  20. Calibration for Relative Interior Orientation Relationship and Band-to-band Registration with High Accuracy of ZY-3 Multi-spectral Image

    Directory of Open Access Journals (Sweden)

    LI Qijun

    2016-06-01

    Full Text Available Using high accuracy match points extracted between the multi-spectral images that obtained at the same time,a position model of the CCD chips of the ZY-3 multi-spectral camera was proposed. Relative interior orientation relationship parameters were calculated and accurate band-to-band automatic registration of ZY-3 multi-spectral image was achieved based on the position model. The experimental result indicates that the band-to-band automatic registration accuracy of ZY-3 multi-spectral image is better than 0.3 pixels with the proposed method.

  1. High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Shaohui Foong

    2016-08-01

    Full Text Available In this paper, a novel magnetic field-based sensing system employing statistically optimized concurrent multiple sensor outputs for precise field-position association and localization is presented. This method capitalizes on the independence between simultaneous spatial field measurements at multiple locations to induce unique correspondences between field and position. This single-source-multi-sensor configuration is able to achieve accurate and precise localization and tracking of translational motion without contact over large travel distances for feedback control. Principal component analysis (PCA is used as a pseudo-linear filter to optimally reduce the dimensions of the multi-sensor output space for computationally efficient field-position mapping with artificial neural networks (ANNs. Numerical simulations are employed to investigate the effects of geometric parameters and Gaussian noise corruption on PCA assisted ANN mapping performance. Using a 9-sensor network, the sensing accuracy and closed-loop tracking performance of the proposed optimal field-based sensing system is experimentally evaluated on a linear actuator with a significantly more expensive optical encoder as a comparison.

  2. High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis

    Science.gov (United States)

    Foong, Shaohui; Sun, Zhenglong

    2016-01-01

    In this paper, a novel magnetic field-based sensing system employing statistically optimized concurrent multiple sensor outputs for precise field-position association and localization is presented. This method capitalizes on the independence between simultaneous spatial field measurements at multiple locations to induce unique correspondences between field and position. This single-source-multi-sensor configuration is able to achieve accurate and precise localization and tracking of translational motion without contact over large travel distances for feedback control. Principal component analysis (PCA) is used as a pseudo-linear filter to optimally reduce the dimensions of the multi-sensor output space for computationally efficient field-position mapping with artificial neural networks (ANNs). Numerical simulations are employed to investigate the effects of geometric parameters and Gaussian noise corruption on PCA assisted ANN mapping performance. Using a 9-sensor network, the sensing accuracy and closed-loop tracking performance of the proposed optimal field-based sensing system is experimentally evaluated on a linear actuator with a significantly more expensive optical encoder as a comparison. PMID:27529253

  3. High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis.

    Science.gov (United States)

    Foong, Shaohui; Sun, Zhenglong

    2016-08-12

    In this paper, a novel magnetic field-based sensing system employing statistically optimized concurrent multiple sensor outputs for precise field-position association and localization is presented. This method capitalizes on the independence between simultaneous spatial field measurements at multiple locations to induce unique correspondences between field and position. This single-source-multi-sensor configuration is able to achieve accurate and precise localization and tracking of translational motion without contact over large travel distances for feedback control. Principal component analysis (PCA) is used as a pseudo-linear filter to optimally reduce the dimensions of the multi-sensor output space for computationally efficient field-position mapping with artificial neural networks (ANNs). Numerical simulations are employed to investigate the effects of geometric parameters and Gaussian noise corruption on PCA assisted ANN mapping performance. Using a 9-sensor network, the sensing accuracy and closed-loop tracking performance of the proposed optimal field-based sensing system is experimentally evaluated on a linear actuator with a significantly more expensive optical encoder as a comparison.

  4. An enhanced Cramér-Rao bound weighted method for attitude accuracy improvement of a star tracker.

    Science.gov (United States)

    Zhang, Jun; Wang, Jian

    2016-06-01

    This study presents a non-average weighted method for the QUEST (QUaternion ESTimator) algorithm, using the inverse value of root sum square of Cramér-Rao bound and focal length drift errors of the tracking star as weight, to enhance the pointing accuracy of a star tracker. In this technique, the stars that are brighter, or at low angular rate, or located towards the center of star field will be given a higher weight in the attitude determination process, and thus, the accuracy is readily improved. Simulations and ground test results demonstrate that, compared to the average weighted method, it can reduce the attitude uncertainty by 10%-20%, which is confirmed particularly for the sky zones with non-uniform distribution of stars. Moreover, by using the iteratively weighted center of gravity algorithm as the newly centroiding method for the QUEST algorithm, the current attitude uncertainty can be further reduced to 44% with a negligible additional computing load.

  5. Analysis of reliability, accuracy, sensitivity and predictive value of a subjective method to classify facial pattern in adults.

    Science.gov (United States)

    Queiroz, Gilberto Vilanova; Rino, José; Paiva, João Batista de; Capelozza, Leopoldino

    2016-01-01

    Craniofacial pattern diagnosis is vital in Orthodontics, as it influences decision-making regarding treatment options and prognosis. Capelozza Filho proposed a subjective method for facial classification comprising five patterns: I, II, III, Long Face and Short Face. To investigate the accuracy of a subjective classification method of facial patterns applied to adults. A sample consisting of 52 adults was used for this study. Frontal and lateral view photographs were taken with subjects at rest position, including frontal smile. Lateral cephalometric radiographs were organized in a PowerPoint® presentation and submitted to 20 raters. Method performance was assessed by examining reproducibility with Kappa test and calculating accuracy, sensitivity and positive predictive values, for which 70% was set as critical value. The gold standard of the classification was personally set by the author of the method. Reproducibility was considered moderate (Kappa = 0.501); while accuracy, sensitivity and positive predictive values yielded similar results, but below 70%. The subjective method of facial classification employed in the present study still needs to have its morphological criteria improved in order to be used to discriminate the five facial patterns.

  6. Comparative analysis of the processing accuracy of high strength metal sheets by AWJ, laser and plasma

    Science.gov (United States)

    Radu, M. C.; Schnakovszky, C.; Herghelegiu, E.; Tampu, N. C.; Zichil, V.

    2016-08-01

    Experimental tests were carried out on two high-strength steel materials (Ramor 400 and Ramor 550). Quantification of the dimensional accuracy was achieved by measuring the deviations from some geometric parameters of part (two lengths and two radii). It was found that in case of Ramor 400 steel, at the jet inlet, the deviations from the part radii are quite small for all the three analysed processes. Instead for the linear dimensions, the deviations are small only in case of laser cutting. At the jet outlet, the deviations raised in small amount compared to those obtained at the jet inlet for both materials as well as for all the three processes. Related to Ramor 550 steel, at the jet inlet the deviations from the part radii are very small in case of AWJ and laser cutting but larger in case of plasma cutting. At the jet outlet, the deviations from the part radii are very small for all processes; in case of linear dimensions, there was obtained very small deviations only in the case of laser processing, the other two processes leading to very large deviations.

  7. A high accuracy broadband measurement system for time resolved complex bioimpedance measurements.

    Science.gov (United States)

    Kaufmann, S; Malhotra, A; Ardelt, G; Ryschka, M

    2014-06-01

    Bioimpedance measurements are useful tools in biomedical engineering and life science. Bioimpedance is the electrical impedance of living tissue and can be used in the analysis of various physiological parameters. Bioimpedance is commonly measured by injecting a small well known alternating current via surface electrodes into an object under test and measuring the resultant surface voltages. It is non-invasive, painless and has no known hazards. This work presents a field programmable gate array based high accuracy broadband bioimpedance measurement system for time resolved bioimpedance measurements. The system is able to measure magnitude and phase of complex impedances under test in a frequency range of about 10-500 kHz with excitation currents from 10 µA to 5 mA. The overall measurement uncertainties stay below 1% for the impedance magnitude and below 0.5° for the phase in most measurement ranges. Furthermore, the described system has a sample rate of up to 3840 impedance spectra per second. The performance of the bioimpedance measurement system is demonstrated with a resistor based system calibration and with measurements on biological samples.

  8. GRACE Data-based High Accuracy Global Static Earth's Gravity Field Model

    Directory of Open Access Journals (Sweden)

    CHEN Qiujie

    2016-04-01

    Full Text Available To recover the highly accurate static earth's gravity field by using GRACE satellite data is one of the hot topics in geodesy. Since linearization errors of dynamic approach quickly increase when extending satellite arc length, we established a modified dynamic approach for processing GRACE orbit and range-rate measurements in this paper, which treated orbit observations of the twin GRACE satellites as approximate values for linearization. Using the GRACE data spanning the period Jan. 2003 to Dec. 2010, containing satellite attitudes, orbits, range-rate, and non-conservative forces, we developed two global static gravity field models. One is the unconstrained solution called Tongji-Dyn01s complete to degree and order 180; the other one is the Tongji-Dyn01k model computed by using Kaula constraint. The comparisons between our models and those latest GRACE-only models (including the AIUB-GRACE03, the GGM05S, the ITSG-Grace2014k and the Tongji-GRACE01 published by different international groups, and the external validations with marine gravity anomalies from DTU13 product and height anomalies from GPS/levelling data, were performed in this study. The results demonstrate that the Tongji-Dyn01s has the same accuracy level with those of the latest GRACE-only models, while the Tongji-Dyn01k model is closer to the EIGEN6C2 than the other GRACE-only models as a whole.

  9. Accuracy Validation of an Automated Method for Prostate Segmentation in Magnetic Resonance Imaging.

    Science.gov (United States)

    Shahedi, Maysam; Cool, Derek W; Bauman, Glenn S; Bastian-Jordan, Matthew; Fenster, Aaron; Ward, Aaron D

    2017-03-24

    Three dimensional (3D) manual segmentation of the prostate on magnetic resonance imaging (MRI) is a laborious and time-consuming task that is subject to inter-observer variability. In this study, we developed a fully automatic segmentation algorithm for T2-weighted endorectal prostate MRI and evaluated its accuracy within different regions of interest using a set of complementary error metrics. Our dataset contained 42 T2-weighted endorectal MRI from prostate cancer patients. The prostate was manually segmented by one observer on all of the images and by two other observers on a subset of 10 images. The algorithm first coarsely localizes the prostate in the image using a template matching technique. Then, it defines the prostate surface using learned shape and appearance information from a set of training images. To evaluate the algorithm, we assessed the error metric values in the context of measured inter-observer variability and compared performance to that of our previously published semi-automatic approach. The automatic algorithm needed an average execution time of ∼60 s to segment the prostate in 3D. When compared to a single-observer reference standard, the automatic algorithm has an average mean absolute distance of 2.8 mm, Dice similarity coefficient of 82%, recall of 82%, precision of 84%, and volume difference of 0.5 cm(3) in the mid-gland. Concordant with other studies, accuracy was highest in the mid-gland and lower in the apex and base. Loss of accuracy with respect to the semi-automatic algorithm was less than the measured inter-observer variability in manual segmentation for the same task.

  10. Therapy evaluation and diagnostic accuracy in neuroendocrine tumours: assessment of radiological methods

    Energy Technology Data Exchange (ETDEWEB)

    Elvin, A.

    1993-01-01

    The diagnostic accuracy of ultrasonically guided biopsy-gun biopsies was assessed in a group of 47 patients with suspected pancreatic carcinoma. A correct diagnosis was obtained in 44 of the 47 patients (94%). Twenty-five patients with known neuroendocrine tumour disease were biopsied with 1.2 mm and 0.9 mm biopsy-gun needles. The influence of treatment-related fibrosis was also evaluated. The overall diagnostic accuracy with the 0.9 mm needle was 69% as compared to 92% with the 1.2 mm needle. In order to assess the diagnostic accuracy rate for radiologists with different experience of biopsy procedures 175 cases of renal biopsy-gun biopsies were evaluated. No statistical significant difference was found between the different operators. The role of duplex Doppler ultrasound in monitoring interferon treatment-related changes in carcinoid metastases was evaluated. It present duplex Doppler ultrasound does not seem to play a role in the evaluation of tumour therapy in carcinoid patients. Therapy response evaluation was performed with MR imaging in a group of 17 patients with neuroendocrine liver metastases. A significant difference was found between patients responding to and patients with failure of treatment in terms of tumour T1, contrast enhancement and signal intensity ratio. This indicates that MR investigation may be used in therapy monitoring of patients with neuroendocrine metastases. The neuroendocrine-differentiated colonic carcinoma cell line (LCC-18) was transplanted to 29 mice to establish a tumour/animal model that would allow the monitoring of changes with MR imaging induced by interferon therapy and to evaluate whether the therapeutic response could be modulated by different interferon dosages. Interferon does not seem to have any prolonged anti-proliferative effect on the LCC-18 tumour cell line when transplanted to nude mice.

  11. Bone QUS measurement performed under loading condition, a more accuracy ultrasound method for osteoporosis diagnosis.

    Science.gov (United States)

    Liu, Chengrui; Niu, Haijun; Fan, Yubo; Li, Deyu

    2012-10-01

    Osteoporosis is a worldwide health problem with enormous social and economic impact. Quantitative ultrasound (QUS) method provides comprehensive information on bone mass, microstructure and mechanical properties of the bone. And the cheap, safe and portable ultrasound equipment is more suitable for public health monitoring. QUS measurement was normally performed on bone specimens without mechanical loading. But human bones are subjected to loading during routine daily activities, and physical loading leads to the changes of bone microstructure and mechanical properties. We hypothesized that bone QUS parameters measured under loading condition differ from those measured without loading because the microstructure of bone was changed when loading subjected to bone. Furthermore, when loading was subjected on bone, the loading-lead microstructure change of osteoporosis bone may larger than that of health bone. By considering the high relationship between bone microstructure and QUS parameters, the QUS parameters of osteoporosis bone may changed larger than that of health bone. So osteoporosis may be detected more effectively by the combination of QUS method and mechanical loading.

  12. Improving accuracy and capabilities of X-ray fluorescence method using intensity ratios

    Science.gov (United States)

    Garmay, Andrey V.; Oskolok, Kirill V.

    2017-04-01

    An X-ray fluorescence analysis algorithm is proposed which is based on a use of ratios of X-ray fluorescence lines intensities. Such an analytical signal is more stable and leads to improved accuracy. Novel calibration equations are proposed which are suitable for analysis in a broad range of matrix compositions. To apply the algorithm to analysis of samples containing significant amount of undetectable elements a use of a dependence of a Rayleigh-to-Compton intensity ratio on a total content of these elements is suggested. The technique's validity is shown by analysis of standard steel samples, model metal oxides mixture and iron ore samples.

  13. Improving accuracy and capabilities of X-ray fluorescence method using intensity ratios

    Energy Technology Data Exchange (ETDEWEB)

    Garmay, Andrey V., E-mail: andrew-garmay@yandex.ru; Oskolok, Kirill V.

    2017-04-15

    An X-ray fluorescence analysis algorithm is proposed which is based on a use of ratios of X-ray fluorescence lines intensities. Such an analytical signal is more stable and leads to improved accuracy. Novel calibration equations are proposed which are suitable for analysis in a broad range of matrix compositions. To apply the algorithm to analysis of samples containing significant amount of undetectable elements a use of a dependence of a Rayleigh-to-Compton intensity ratio on a total content of these elements is suggested. The technique's validity is shown by analysis of standard steel samples, model metal oxides mixture and iron ore samples.

  14. On the accuracy of density functional theory and wave function methods for calculating vertical ionization energies

    Energy Technology Data Exchange (ETDEWEB)

    McKechnie, Scott [Cavendish Laboratory, Department of Physics, University of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Booth, George H. [Theory and Simulation of Condensed Matter, King’s College London, The Strand, London WC2R 2LS (United Kingdom); Cohen, Aron J. [Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW (United Kingdom); Cole, Jacqueline M., E-mail: jmc61@cam.ac.uk [Cavendish Laboratory, Department of Physics, University of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Argonne National Laboratory, 9700 S Cass Avenue, Argonne, Illinois 60439 (United States)

    2015-05-21

    The best practice in computational methods for determining vertical ionization energies (VIEs) is assessed, via reference to experimentally determined VIEs that are corroborated by highly accurate coupled-cluster calculations. These reference values are used to benchmark the performance of density functional theory (DFT) and wave function methods: Hartree-Fock theory, second-order Møller-Plesset perturbation theory, and Electron Propagator Theory (EPT). The core test set consists of 147 small molecules. An extended set of six larger molecules, from benzene to hexacene, is also considered to investigate the dependence of the results on molecule size. The closest agreement with experiment is found for ionization energies obtained from total energy difference calculations. In particular, DFT calculations using exchange-correlation functionals with either a large amount of exact exchange or long-range correction perform best. The results from these functionals are also the least sensitive to an increase in molecule size. In general, ionization energies calculated directly from the orbital energies of the neutral species are less accurate and more sensitive to an increase in molecule size. For the single-calculation approach, the EPT calculations are in closest agreement for both sets of molecules. For the orbital energies from DFT functionals, only those with long-range correction give quantitative agreement with dramatic failing for all other functionals considered. The results offer a practical hierarchy of approximations for the calculation of vertical ionization energies. In addition, the experimental and computational reference values can be used as a standardized set of benchmarks, against which other approximate methods can be compared.

  15. Accuracy evaluation of both Wallace-Bott and BEM-based paleostress inversion methods

    Science.gov (United States)

    Lejri, Mostfa; Maerten, Frantz; Maerten, Laurent; Soliva, Roger

    2017-01-01

    Four decades after their introduction, the validity of fault slip inversion methods based on Wallace (1951) and Bott (1959) hypothesis, which states that the slip on each fault surface has the same direction and sense as the maximum resolved shear stress, is still a subject of debate. According to some authors, this hypothesis is questionable since fault mechanical interactions induce slip reorientations as confirmed by geomechanical models. This leads us to ask as to what extent the Wallace-Bott simplifications are reliable as a basis hypothesis for stress inversion from fault slip data. In this paper, we compare two inversion methods; the first is based on the Wallace-Bott hypothesis, and the second relies on geomechanics and mechanical effects on fault heterogeneous slip distribution. In that context, a multi-parametric stress inversion study covering (i) the friction coefficients (μ), (ii) the full range of Andersonian state of stress and (iii) slip data sampling along the faults is performed. For each tested parameter, the results of the mechanical stress inversion and the Wallace-Bott (WB) based stress inversion for slip are compared in order to understand their respective effects. The predicted discrepancy between the solutions of both stress inversion methods (based on WB and mechanics) will then be used to explain the stress inversions results for the chimney Rock case study. It is shown that a high solution discrepancy is not always correlated with the misfit angle (ω) and can be found under specific configurations (R-, θ, μ, geometry) invalidating the WB solutions. We conclude that in most cases the mechanical stress inversion and the WB based stress inversion are both valid and complementary depending on the fault friction. Some exceptions (i.e. low fault friction, simple fault geometry and pure regimes) that may lead to wrong WB based stress inversion solutions are highlighted.

  16. On the accuracy of density functional theory and wave function methods for calculating vertical ionization energies

    Science.gov (United States)

    McKechnie, Scott; Booth, George H.; Cohen, Aron J.; Cole, Jacqueline M.

    2015-05-01

    The best practice in computational methods for determining vertical ionization energies (VIEs) is assessed, via reference to experimentally determined VIEs that are corroborated by highly accurate coupled-cluster calculations. These reference values are used to benchmark the performance of density functional theory (DFT) and wave function methods: Hartree-Fock theory, second-order Møller-Plesset perturbation theory, and Electron Propagator Theory (EPT). The core test set consists of 147 small molecules. An extended set of six larger molecules, from benzene to hexacene, is also considered to investigate the dependence of the results on molecule size. The closest agreement with experiment is found for ionization energies obtained from total energy difference calculations. In particular, DFT calculations using exchange-correlation functionals with either a large amount of exact exchange or long-range correction perform best. The results from these functionals are also the least sensitive to an increase in molecule size. In general, ionization energies calculated directly from the orbital energies of the neutral species are less accurate and more sensitive to an increase in molecule size. For the single-calculation approach, the EPT calculations are in closest agreement for both sets of molecules. For the orbital energies from DFT functionals, only those with long-range correction give quantitative agreement with dramatic failing for all other functionals considered. The results offer a practical hierarchy of approximations for the calculation of vertical ionization energies. In addition, the experimental and computational reference values can be used as a standardized set of benchmarks, against which other approximate methods can be compared.

  17. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (˜100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ˜0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  18. Application of the PM6 semi-empirical method to modeling proteins enhances docking accuracy of AutoDock.

    Science.gov (United States)

    Bikadi, Zsolt; Hazai, Eszter

    2009-09-11

    Molecular docking methods are commonly used for predicting binding modes and energies of ligands to proteins. For accurate complex geometry and binding energy estimation, an appropriate method for calculating partial charges is essential. AutoDockTools software, the interface for preparing input files for one of the most widely used docking programs AutoDock 4, utilizes the Gasteiger partial charge calculation method for both protein and ligand charge calculation. However, it has already been shown that more accurate partial charge calculation - and as a consequence, more accurate docking- can be achieved by using quantum chemical methods. For docking calculations quantum chemical partial charge calculation as a routine was only used for ligands so far. The newly developed Mozyme function of MOPAC2009 allows fast partial charge calculation of proteins by quantum mechanical semi-empirical methods. Thus, in the current study, the effect of semi-empirical quantum-mechanical partial charge calculation on docking accuracy could be investigated. The docking accuracy of AutoDock 4 using the original AutoDock scoring function was investigated on a set of 53 protein ligand complexes using Gasteiger and PM6 partial charge calculation methods. This has enabled us to compare the effect of the partial charge calculation method on docking accuracy utilizing AutoDock 4 software. Our results showed that the docking accuracy in regard to complex geometry (docking result defined as accurate when the RMSD of the first rank docking result complex is within 2 A of the experimentally determined X-ray structure) significantly increased when partial charges of the ligands and proteins were calculated with the semi-empirical PM6 method. Out of the 53 complexes analyzed in the course of our study, the geometry of 42 complexes were accurately calculated using PM6 partial charges, while the use of Gasteiger charges resulted in only 28 accurate geometries. The binding affinity estimation was

  19. Geometric Accuracy Investigations of SEVIRI High Resolution Visible (HRV) Level 1.5 Imagery

    National Research Council Canada - National Science Library

    Sultan Kocaman Aksakal

    2013-01-01

    .... In a joint project between the Swiss GCOS Office and ETH Zurich, geometric accuracy and temporal stability of 1-km resolution HRV channel imagery of SEVIRI have been evaluated over Switzerland...

  20. The regulatory benefits of high levels of affect perception accuracy: a process analysis of reactions to stressors in daily life.

    Science.gov (United States)

    Robinson, Michael D; Moeller, Sara K; Buchholz, Maria M; Boyd, Ryan L; Troop-Gordon, Wendy

    2012-08-01

    Individuals attuned to affective signals from the environment may possess an advantage in the emotion-regulation realm. In two studies (total n = 151), individual differences in affective perception accuracy were assessed in an objective, performance-based manner. Subsequently, the same individuals completed daily diary protocols in which daily stressor levels were reported as well as problematic states shown to be stress-reactive in previous studies. In both studies, individual differences in affect perception accuracy interacted with daily stressor levels to predict the problematic outcomes. Daily stressors precipitated problematic reactions--whether depressive feelings (study 1) or somatic symptoms (study 2)--at low levels of affect perception accuracy, but did not do so at high levels of affect perception accuracy. The findings support a regulatory view of such perceptual abilities. Implications for understanding emotion regulation processes, emotional intelligence, and individual differences in reactivity are discussed.

  1. [Accuracy of liquid-based cytology in diagnosis of high-grade squamous cervical intraepithelial neoplasia].

    Science.gov (United States)

    Li, Min; Mei, Ping; Luo, Dong-lan; Wang, Xiao-bing; Liu, Yan-hui

    2012-04-01

    To investigate factors affecting the diagnostic accuracy of cervical liquid-based cytology for high-grade squamous intraepithelial lesion (HSIL). A retrospective evaluation of cytological and histological slides was performed in 415 patients who had cytological HSIL between 2007 and 2010. Among 42 209 cases screened by ThinPrep liquid-based cytology, 415 cases (1.0%) of HSIL were eventually identified. The mean age of HSIL patients was 41.6 years, and 30-49 years were the most common age group. Among 415 cases, 325 patients had available histological diagnosis as follows: 23 (7.1%) negative, 22 (6.8%) CIN1/HPV, 223 (68.6%) CIN2/CIN3, and 57 (17.5%) squamous cell carcinoma (SCC). The positive predictive values of HSIL to predict CIN2 (or higher grade of dysplasia) and CIN1 were 86.2% (280/325) and 92.9% (302/325), respectively. Inadequate biopsy, reactive glandular cells, islet atrophy, chemo/radiotherapy and others were responsible for the cytologically false-positive diagnosis. Fifty-seven (17.5%) cases of HSIL had a histological diagnosis of SCC. The possible causes of misdiagnosis were social factors, under-recognized cytological features of poorly-differentiated SCC and absence of typical diagnostic features in cytology slides. Cytology of HSIL has a high positive predictive value for the presence of CIN2/CIN3 and SCC. Cytologists and gynecologists should be aware of the diagnostic pitfalls that may lead to the discrepancy between cytology and histology.

  2. Achieving numerical accuracy and high performance using recursive tile LU factorization with partial pivoting

    KAUST Repository

    Dongarra, Jack

    2013-09-18

    The LU factorization is an important numerical algorithm for solving systems of linear equations in science and engineering and is a characteristic of many dense linear algebra computations. For example, it has become the de facto numerical algorithm implemented within the LINPACK benchmark to rank the most powerful supercomputers in the world, collected by the TOP500 website. Multicore processors continue to present challenges to the development of fast and robust numerical software due to the increasing levels of hardware parallelism and widening gap between core and memory speeds. In this context, the difficulty in developing new algorithms for the scientific community resides in the combination of two goals: achieving high performance while maintaining the accuracy of the numerical algorithm. This paper proposes a new approach for computing the LU factorization in parallel on multicore architectures, which not only improves the overall performance but also sustains the numerical quality of the standard LU factorization algorithm with partial pivoting. While the update of the trailing submatrix is computationally intensive and highly parallel, the inherently problematic portion of the LU factorization is the panel factorization due to its memory-bound characteristic as well as the atomicity of selecting the appropriate pivots. Our approach uses a parallel fine-grained recursive formulation of the panel factorization step and implements the update of the trailing submatrix with the tile algorithm. Based on conflict-free partitioning of the data and lockless synchronization mechanisms, our implementation lets the overall computation flow naturally without contention. The dynamic runtime system called QUARK is then able to schedule tasks with heterogeneous granularities and to transparently introduce algorithmic lookahead. The performance results of our implementation are competitive compared to the currently available software packages and libraries. For example

  3. Two-dimensional DOA Estimation with High Accuracy for MIMO Radar Using Cross Array

    Directory of Open Access Journals (Sweden)

    Liang Hao

    2016-06-01

    Full Text Available In this study, we investigate the estimation of the Two-Dimensional (2D Direction Of Arrival (DOA in monostatic multiple-input–multiple-output radar with cross array and propose a novel, highly accurate DOA estimation method based on unitary transformation. First, we design a new unitary matrix using the central symmetry of a cross array at transmit and receive sites. Then, the rotational invariance relationships of these arrays with long and short baselines can be transformed into a real-value field via unitary transformation. In addition, non-ambiguous and highly accurate 2D DOA estimations can be obtained using a unitary dual-resolution ESPRIT algorithm. Simulations show that the proposed method can estimate 2D highly accurate spatial angles using automatic pairing without incurring the expense of array aperture and peak searching. Compared with traditional unitary transformation, the steering vectors of transmit and receive arrays can be transformed into real-value fields via the unitary matrix and the transformation method of our scheme, respectively. This effectively overcomes the problem of shift invariance factors in real-value fields that cannot be extracted using traditional algorithms. Therefore, the proposed method can absolutely compute eigenvalue decomposition and estimate parameters in a real-value field, resulting in lower computational complexity compared with traditional methods. Simulation results verify both the correctness of our theoretical analysis and the effectiveness of the proposed algorithm.

  4. A two-zone method with an enhanced accuracy for a numerical solution of the diffusion equation

    Science.gov (United States)

    Cheon, Jin-Sik; Koo, Yang-Hyun; Lee, Byung-Ho; Oh, Je-Yong; Sohn, Dong-Seong

    2006-12-01

    A variational principle is applied to the diffusion equation to numerically obtain the fission gas release from a spherical grain. The two-zone method, originally proposed by Matthews and Wood, is modified to overcome its insufficient accuracy for a low release. The results of the variational approaches are examined by observing the gas concentration along the grain radius. At the early stage, the concentration near the grain boundary is higher than that at the inner points of the grain in the cases of the two-zone method as well as the finite element analysis with the number of the elements at as many as 10. The accuracy of the two-zone method is considerably enhanced by relocating the nodal points of the two zones. The trial functions are derived as a function of the released fraction. During the calculations, the number of degrees of freedom needs to be reduced to guarantee physically admissible concentration profiles. Numerical verifications are performed extensively. By taking a computational time comparable to the algorithm by Forsberg and Massih, the present method provides a solution with reasonable accuracy in the whole range of the released fraction.

  5. Numerical simulation for accuracy of velocity analysis in small-scale high-resolution marine multichannel seismic technology

    Science.gov (United States)

    Luo, Di; Cai, Feng; Wu, Zhiqiang

    2017-06-01

    When used with large energy sparkers, marine multichannel small-scale high-resolution seismic detection technology has a high resolution, high-detection precision, a wide applicable range, and is very flexible. Positive results have been achieved in submarine geological research, particularly in the investigation of marine gas hydrates. However, the amount of traveltime difference information is reduced for the velocity analysis under conditions of a shorter spread length, thus leading to poorer focusing of the velocity spectrum energy group and a lower accuracy of the velocity analysis. It is thus currently debatable whether the velocity analysis accuracy of short-arrangement multichannel seismic detection technology is able to meet the requirements of practical application in natural gas hydrate exploration. Therefore, in this study the bottom boundary of gas hydrates (Bottom Simulating Reflector, BSR) is used to conduct numerical simulation to discuss the accuracy of the velocity analysis related to such technology. Results show that a higher dominant frequency and smaller sampling interval are not only able to improve the seismic resolution, but they also compensate for the defects of the short-arrangement, thereby improving the accuracy of the velocity analysis. In conclusion, the accuracy of the velocity analysis in this small-scale, high-resolution, multi-channel seismic detection technology meets the requirements of natural gas hydrate exploration.

  6. Towards Building Reliable, High-Accuracy Solar Irradiance Database For Arid Climates

    Science.gov (United States)

    Munawwar, S.; Ghedira, H.

    2012-12-01

    Middle East's growing interest in renewable energy has led to increased activity in solar technology development with the recent commissioning of several utility-scale solar power projects and many other commercial installations across the Arabian Peninsula. The region, lying in a virtually rainless sunny belt with a typical daily average solar radiation exceeding 6 kWh/m2, is also one of the most promising candidates for solar energy deployment. However, it is not the availability of resource, but its characterization and reasonably accurate assessment that determines the application potential. Solar irradiance, magnitude and variability inclusive, is the key input in assessing the economic feasibility of a solar system. The accuracy of such data is of critical importance for realistic on-site performance estimates. This contribution aims to identify the key stages in developing a robust solar database for desert climate by focusing on the challenges that an arid environment presents to parameterization of solar irradiance attenuating factors. Adjustments are proposed based on the currently available resource assessment tools to produce high quality data for assessing bankability. Establishing and maintaining ground solar irradiance measurements is an expensive affair and fairly limited in time (recently operational) and space (fewer sites) in the Gulf region. Developers within solar technology industry, therefore, rely on solar radiation models and satellite-derived data for prompt resource assessment needs. It is imperative that such estimation tools are as accurate as possible. While purely empirical models have been widely researched and validated in the Arabian Peninsula's solar modeling history, they are known to be intrinsically site-specific. A primal step to modeling is an in-depth understanding of the region's climate, identifying the key players attenuating radiation and their appropriate characterization to determine solar irradiance. Physical approach

  7. Accuracy of dementia diagnosis—a direct comparison between radiologists and a computerized method

    Science.gov (United States)

    Stonnington, Cynthia M.; Barnes, Josephine; Chen, Frederick; Chu, Carlton; Good, Catriona D.; Mader, Irina; Mitchell, L. Anne; Patel, Ameet C.; Roberts, Catherine C.; Fox, Nick C.; Jack, Clifford R.; Ashburner, John; Frackowiak, Richard S. J.

    2008-01-01

    There has been recent interest in the application of machine learning techniques to neuroimaging-based diagnosis. These methods promise fully automated, standard PC-based clinical decisions, unbiased by variable radiological expertise. We recently used support vector machines (SVMs) to separate sporadic Alzheimer's disease from normal ageing and from fronto-temporal lobar degeneration (FTLD). In this study, we compare the results to those obtained by radiologists. A binary diagnostic classification was made by six radiologists with different levels of experience on the same scans and information that had been previously analysed with SVM. SVMs correctly classified 95% (sensitivity/specificity: 95/95) of sporadic Alzheimer's disease and controls into their respective groups. Radiologists correctly classified 65–95% (median 89%; sensitivity/specificity: 88/90) of scans. SVM correctly classified another set of sporadic Alzheimer's disease in 93% (sensitivity/specificity: 100/86) of cases, whereas radiologists ranged between 80% and 90% (median 83%; sensitivity/specificity: 80/85). SVMs were better at separating patients with sporadic Alzheimer's disease from those with FTLD (SVM 89%; sensitivity/specificity: 83/95; compared to radiological range from 63% to 83%; median 71%; sensitivity/specificity: 64/76). Radiologists were always accurate when they reported a high degree of diagnostic confidence. The results show that well-trained neuroradiologists classify typical Alzheimer's disease-associated scans comparable to SVMs. However, SVMs require no expert knowledge and trained SVMs can readily be exchanged between centres for use in diagnostic classification. These results are encouraging and indicate a role for computerized diagnostic methods in clinical practice. PMID:18835868

  8. Accuracy of dementia diagnosis: a direct comparison between radiologists and a computerized method.

    Science.gov (United States)

    Klöppel, Stefan; Stonnington, Cynthia M; Barnes, Josephine; Chen, Frederick; Chu, Carlton; Good, Catriona D; Mader, Irina; Mitchell, L Anne; Patel, Ameet C; Roberts, Catherine C; Fox, Nick C; Jack, Clifford R; Ashburner, John; Frackowiak, Richard S J

    2008-11-01

    There has been recent interest in the application of machine learning techniques to neuroimaging-based diagnosis. These methods promise fully automated, standard PC-based clinical decisions, unbiased by variable radiological expertise. We recently used support vector machines (SVMs) to separate sporadic Alzheimer's disease from normal ageing and from fronto-temporal lobar degeneration (FTLD). In this study, we compare the results to those obtained by radiologists. A binary diagnostic classification was made by six radiologists with different levels of experience on the same scans and information that had been previously analysed with SVM. SVMs correctly classified 95% (sensitivity/specificity: 95/95) of sporadic Alzheimer's disease and controls into their respective groups. Radiologists correctly classified 65-95% (median 89%; sensitivity/specificity: 88/90) of scans. SVM correctly classified another set of sporadic Alzheimer's disease in 93% (sensitivity/specificity: 100/86) of cases, whereas radiologists ranged between 80% and 90% (median 83%; sensitivity/specificity: 80/85). SVMs were better at separating patients with sporadic Alzheimer's disease from those with FTLD (SVM 89%; sensitivity/specificity: 83/95; compared to radiological range from 63% to 83%; median 71%; sensitivity/specificity: 64/76). Radiologists were always accurate when they reported a high degree of diagnostic confidence. The results show that well-trained neuroradiologists classify typical Alzheimer's disease-associated scans comparable to SVMs. However, SVMs require no expert knowledge and trained SVMs can readily be exchanged between centres for use in diagnostic classification. These results are encouraging and indicate a role for computerized diagnostic methods in clinical practice.

  9. Energy levels of interacting curved nanomagnets in a frustrated geometry: increasing accuracy when using finite difference methods.

    Science.gov (United States)

    Riahi, H; Montaigne, F; Rougemaille, N; Canals, B; Lacour, D; Hehn, M

    2013-07-24

    The accuracy of finite difference methods is related to the mesh choice and cell size. Concerning the micromagnetism of nano-objects, we show here that discretization issues can drastically affect the symmetry of the problem and therefore the resulting computed properties of lattices of interacting curved nanomagnets. In this paper, we detail these effects for the multi-axis kagome lattice. Using the OOMMF finite difference method, we propose an alternative way of discretizing the nanomagnet shape via a variable moment per cell scheme. This method is shown to be efficient in reducing discretization effects.

  10. The analysis of the accuracy of the wheel alignment inspection method on the side-slip plate stand

    Science.gov (United States)

    Gajek, A.; Strzępek, P.

    2016-09-01

    The article presents the theoretical basis and the results of the examination of the wheel alignment inspection method on the slide slip plate stand. It is obligatory test during periodic technical inspection of the vehicle. The measurement is executed in the dynamic conditions. The dependence between the lateral displacement of the plate and toe-in of the tested wheels has been shown. If the diameter of the wheel rim is known then the value of the toe-in can be calculated. The comparison of the toe-in measurements on the plate stand and on the four heads device for the wheel alignment inspection has been carried out. The accuracy of the measurements and the influence of the conditions of the tests on the plate stand (the way of passing through the plate) were estimated. The conclusions about the accuracy of this method are presented.

  11. IMPLEMENTATION OF SEMI-EMPIRICAL MODELS TO ENHANCE THE ACCURACY OF PANEL METHODS FOR DRAG PREDICTION AT SUPERSONIC SPEEDS

    Directory of Open Access Journals (Sweden)

    Abdulkareem Shafiq Mahdi Al-Obaidi

    2011-12-01

    Full Text Available 0 0 1 328 1876 International Islamic University 15 4 2200 14.0 Normal 0 false false false EN-US JA X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Times New Roman";} This paper introduces an attempt to enhance the accuracy of panel methods. A low-order panel method is selected and coupled with semi-empirical methods to enhance the accuracy of drag prediction of flying bodies at supersonic speeds. The semi-empirical methods are used to improve the accuracy of drag prediction by mathematical modelling of viscosity, base drag, and drag due to wing-body interference. Both methods were implemented by a computer program and validated against experimental and analytical results. The comparisons show that a considerable improvement has been achieved for the selected panel method for prediction of drag coefficients. In general, accuracy within an average value of -4.4% was obtained for the enhanced panel method. Such accuracy could be considered acceptable for the preliminary design stages of supersonic flying bodies such as projectiles and missiles. The developed computer program gives satisfactory results as long as the considered configurations are slender and the angles of attack are small (below stall angle.  ABSTRAK: Kertas kerja ini memperkenalkan percubaan untuk  mempertingkatkan ketepatan kaedah panel. Kaedah panel tertib rendah telah dipilih dan digabungkan dengan kaedah separa empirik untuk mempertingkatkan ketepatan ramalan seret objek terbang pada kelajuan supersonik. Kaedah semi empirikal yang digunakan untuk meningkatkan ketepatan jangkaan seret menggunakan model matematik bagi kelikatan, seretan dasar, dan  seretan disebabkan  oleh

  12. Expression of CRM1 and CDK5 shows high prognostic accuracy for gastric cancer

    Science.gov (United States)

    Sun, Yu-Qin; Xie, Jian-Wei; Xie, Hong-Teng; Chen, Peng-Chen; Zhang, Xiu-Li; Zheng, Chao-Hui; Li, Ping; Wang, Jia-Bin; Lin, Jian-Xian; Cao, Long-Long; Huang, Chang-Ming; Lin, Yao

    2017-01-01

    AIM To evaluate the predictive value of the expression of chromosomal maintenance (CRM)1 and cyclin-dependent kinase (CDK)5 in gastric cancer (GC) patients after gastrectomy. METHODS A total of 240 GC patients who received standard gastrectomy were enrolled in the study. The expression level of CRM1 and CDK5 was detected by immunohistochemistry. The correlations between CRM1 and CDK5 expression and clinicopathological factors were explored. Univariate and multivariate survival analyses were used to identify prognostic factors for GC. Receiver operating characteristic analysis was used to compare the accuracy of the prediction of clinical outcome by the parameters. RESULTS The expression of CRM1 was significantly related to size of primary tumor (P = 0.005), Borrmann type (P = 0.006), degree of differentiation (P = 0.004), depth of invasion (P = 0.008), lymph node metastasis (P = 0.013), TNM stage (P = 0.002) and distant metastasis (P = 0.015). The expression of CDK5 was significantly related to sex (P = 0.048) and Lauren’s classification (P = 0.011). Multivariate Cox regression analysis identified that CRM1 and CDK5 co-expression status was an independent prognostic factor for overall survival (OS) of patients with GC. Integration of CRM1 and CDK5 expression could provide additional prognostic value for OS compared with CRM1 or CDK5 expression alone (P = 0.001). CONCLUSION CRM1 and CDK5 co-expression was an independent prognostic factors for GC. Combined CRM1 and CDK5 expression could provide a prognostic model for OS of GC. PMID:28373767

  13. Automated, high accuracy classification of Parkinsonian disorders: a pattern recognition approach.

    Directory of Open Access Journals (Sweden)

    Andre F Marquand

    Full Text Available Progressive supranuclear palsy (PSP, multiple system atrophy (MSA and idiopathic Parkinson's disease (IPD can be clinically indistinguishable, especially in the early stages, despite distinct patterns of molecular pathology. Structural neuroimaging holds promise for providing objective biomarkers for discriminating these diseases at the single subject level but all studies to date have reported incomplete separation of disease groups. In this study, we employed multi-class pattern recognition to assess the value of anatomical patterns derived from a widely available structural neuroimaging sequence for automated classification of these disorders. To achieve this, 17 patients with PSP, 14 with IPD and 19 with MSA were scanned using structural MRI along with 19 healthy controls (HCs. An advanced probabilistic pattern recognition approach was employed to evaluate the diagnostic value of several pre-defined anatomical patterns for discriminating the disorders, including: (i a subcortical motor network; (ii each of its component regions and (iii the whole brain. All disease groups could be discriminated simultaneously with high accuracy using the subcortical motor network. The region providing the most accurate predictions overall was the midbrain/brainstem, which discriminated all disease groups from one another and from HCs. The subcortical network also produced more accurate predictions than the whole brain and all of its constituent regions. PSP was accurately predicted from the midbrain/brainstem, cerebellum and all basal ganglia compartments; MSA from the midbrain/brainstem and cerebellum and IPD from the midbrain/brainstem only. This study demonstrates that automated analysis of structural MRI can accurately predict diagnosis in individual patients with Parkinsonian disorders, and identifies distinct patterns of regional atrophy particularly useful for this process.

  14. Autotaxin activity has a high accuracy to diagnose intrahepatic cholestasis of pregnancy.

    Science.gov (United States)

    Kremer, Andreas E; Bolier, Ruth; Dixon, Peter H; Geenes, Victoria; Chambers, Jenny; Tolenaars, Dagmar; Ris-Stalpers, Carrie; Kaess, Bernhard M; Rust, Christian; van der Post, Joris A; Williamson, Catherine; Beuers, Ulrich; Oude Elferink, Ronald P J

    2015-04-01

    Intrahepatic cholestasis of pregnancy (ICP) is defined by pruritus, elevated total fasting serum bile salts (TBS) and transaminases, and an increased risk of adverse fetal outcome. An accurate diagnostic marker is needed. Increased serum autotaxin correlates with cholestasis-associated pruritus. We aimed at unraveling the diagnostic accuracy of autotaxin in ICP. Serum samples and placental tissue were collected from 44 women with uncomplicated pregnancies and 105 with pruritus and/or elevated serum transaminases. Autotaxin serum levels were quantified enzymatically and by Western blotting, autotaxin gene expression by quantitative PCR. Serum autotaxin was increased in ICP (mean ± SD: 43.5 ± 18.2 nmol ml(-1)min(-1), n=55, ppregnancy (16.8 ± 6.7 nmol ml(-1)min(-1), n=33), pre-eclampsia complicated by HELLP-syndrome (16.8 ± 8.9 nmol ml(-1)min(-1), n=17), and pregnant controls (19.6 ± 5.7 nmol ml(-1)min(-1), n=44). Longitudinal analysis during pregnancy revealed a marked rise in serum autotaxin with onset of ICP-related pruritus. Serum autotaxin was increased in women taking oral contraceptives. Increased serum autotaxin during ICP was not associated with increased autotaxin mRNA in placenta. With a cut-off value of 27.0 nmol ml(-1)min(-1), autotaxin had an excellent sensitivity and specificity in distinguishing ICP from other pruritic disorders or pre-eclampsia/HELLP-syndrome. Serum autotaxin displayed no circadian rhythm and was not influenced by food intake. Increased serum autotaxin activity represents a highly sensitive, specific and robust diagnostic marker of ICP, distinguishing ICP from other pruritic disorders of pregnancy and pregnancy-related liver diseases. Pregnancy and oral contraception increase serum autotaxin to a much lesser extent than ICP. Copyright © 2014 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  15. High accuracy of arterial spin labeling perfusion imaging in differentiation of pilomyxoid from pilocytic astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, S.A.; Assadsangabi, R.; Hajmomenian, M.; Vossough, A. [Perelman School of Medicine of the University of Pennsylvania, Department of Radiology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Santi, M. [Perelman School of Medicine of the University of Pennsylvania, Department of Pathology, Children' s Hospital of Philadelphia, Philadelphia, PA (United States)

    2015-05-01

    Pilomyxoid astrocytoma (PMA) is a relatively new tumor entity which has been added to the 2007 WHO Classification of tumors of the central nervous system. The goal of this study is to utilize arterial spin labeling (ASL) perfusion imaging to differentiate PMA from pilocytic astrocytoma (PA). Pulsed ASL and conventional MRI sequences of patients with PMA and PA in the past 5 years were retrospectively evaluated. Patients with history of radiation or treatment with anti-angiogenic drugs were excluded. A total of 24 patients (9 PMA, 15 PA) were included. There were statistically significant differences between PMA and PA in mean tumor/gray matter (GM) cerebral blood flow (CBF) ratios (1.3 vs 0.4, p < 0.001) and maximum tumor/GM CBF ratio (2.3 vs 1, p < 0.001). Area under the receiver operating characteristic (ROC) curves for differentiation of PMA from PA was 0.91 using mean tumor CBF, 0.95 using mean tumor/GM CBF ratios, and 0.89 using maximum tumor/GM CBF. Using a threshold value of 0.91, the mean tumor/GM CBF ratio was able to diagnose PMA with 77 % sensitivity, 100 % specificity, and a threshold value of 0.7, provided 88 % sensitivity and 86 % specificity. There was no statistically significant difference between the two tumors in enhancement pattern (p = 0.33), internal architecture (p = 0.15), or apparent diffusion coefficient (ADC) values (p = 0.07). ASL imaging has high accuracy in differentiating PMA from PA. The result of this study may have important applications in prognostication and treatment planning especially in patients with less accessible tumors such as hypothalamic-chiasmatic gliomas. (orig.)

  16. High Resolution Ice Surface of the Ross Ice Shelf: Accuracy and Links to Basal Processes

    Science.gov (United States)

    Starke, S. E.

    2015-12-01

    We use airborne laser altimetry data from IcePod and IceBridge to map the surface across the Ross Ice Shelf in Antarctica. Laser altimetry and radar data is analyzed from the IcePod 2014 and 2015 field campaigns as well as IceBridge 2013. Icepod is a multi sensor suite that includes ice penetrating radars, a swath scanning laser, visible and IR cameras as well as GPS mounted on a LC-130. Using shallow ice radar data from both IcePod and IceBridge we identify the base of the ice shelf. Across the shelf we observe distinct areas of high reflectivity in the radar data suggesting basal crevassing. In some regions, the basal reflector is not well defined. Laser altimetry profiles correlate surface morphology with features at the base including basal crevasses and marine ice formed by freezing on to the base of the ice shelf. Building Digital Elevation Models (DEMs) from the laser altimetry data, we investigate the relationship between the surface expressions of these ice shelf dynamics including thickness changes, potential sites of marine ice at the base and basal morphology in regions where a well defined basal reflector does not exist in the radar profiles. We present accuracy of the IcePod laser altimetry dataset using ground control points and GPS grids from Greenland and Antarctica as well as Photogrammetric DEMs. Our laser altimetry analysis resolves sub-meter surface features which, combined with coincident radar, provides a link between basal processes and their surface expressions.

  17. The research of digital circuit system for high accuracy CCD of portable Raman spectrometer