WorldWideScience

Sample records for hgi2 surgical probes

  1. Beer Law Constants and Vapor Pressures of HgI2 over HgI2(s,l)

    Science.gov (United States)

    Su, Ching-Hua; Zhu, Shen; Ramachandran, N.; Burger, A.

    2002-01-01

    Optical absorption spectra of the vapor phase over HgI2(s,l) were measured at sample temperatures between 349 and 610 K for wavelengths between 200 and 600 nm. The spectra show the samples sublimed congruently into HGI2 without any observed Hg or I2 absorption spectra. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were derived. From these constants the vapor pressure of HgI2, P, was found to be a function of temperature for the liquid and the solid beta-phases: ln P(atm) = -7700/T(K) + 12.462 (liquid phase) and ln P(atm) = -10150/T(K) + 17.026 (beta-phase). The expressions match the enthalpies of vaporization and sublimation of 15.30 and 20.17 kcal/mole respectively, for the liquid and the beta-phase HgI2. The difference in the enthalpies gives an enthalpy of fusion of 4.87 kcal/mole, and the intersection of the two expressions gives a melting point of 537 K.

  2. Purification of HGI2 for nuclear detector fabrication

    International Nuclear Information System (INIS)

    Schieber, M.M.

    1978-01-01

    A process for purification of mercuric iodide (HgI 2 ) to be used as a source material for the growth of detector quality crystals. The high purity HgI 2 raw material is produced by a combination of three stages: synthesis of HgI 2 from Hg and I 2 , repeated sublimation, and zone refining

  3. Use of HgI2 as gamma radiation detector

    International Nuclear Information System (INIS)

    Perez Morales, J.M.

    1993-01-01

    The Mercuric Iodide (HgI 2 ) has become one of the most promising room temperature semiconductors for the construction of X and gamma radiation detectors. The classical methods of spectroscopy have not demonstrated to achieve optimum results with HgI 2 detectors, mainly due to its particular carrier transport properties. Several alternative spectroscopic methods developed in the last ten years are presented and commented, selecting for a complete study one of them: 'The Partial Charge Collection Method'. The transport properties of the carriers generated by the radiation in the detector is specially important for understanding the spectroscopic behaviour of the HgI 2 detectors. For a rigorous characterization of this transport, it has been studied a digital technique for the analysis of the electric pulses produced by the radiation. Theoretically, it has been developed a Monte Carlo simulation of the radiation detection and the electronic signal treatment processes with these detectors in the energy range of 60-1300 KeV. These codes are applied to the study of the The Partial Charge Collection Method and its comparison with gaussian methods. Experimentally, this digital techniques is used for the study of the transport properties of thin HgI 2 detectors. Special interest is given to the contribution of the slower carriers, the holes, obtaining some consequent of spectroscopic interest. Finally, it is presented the results obtained with the first detectors grown and mounted in CIEMAT with own technology. (author). 129 ref

  4. HgI2 nanostructures obtained hydrothermally for application in ionizing radiation detection

    International Nuclear Information System (INIS)

    Pérez Barthaburu, María; Bentos Pereira, Heinkel; Fornaro, Laura; Galain, Isabel; Aguiar, Ivana

    2016-01-01

    The compound semiconductor HgI 2 has been widely studied and employed as a material for ionizing radiation detection. Monocrystal growth is an intricate method for obtaining materials for this application. With the aim of finding a simpler and more effective way to develop ionizing radiation detectors, we employed HgI 2 nanostructures subjected to a hydrothermal treatment and then pressed for this purpose. In the synthesis procedure, aqueous solutions of Hg(NO 3 ) 2 and NaI were mixed until their reaction completed and the suspension obtained was then placed in a homemade autoclave and heated at 120 °C for 2, 10 or 24 h. We confirmed the HgI 2 tetragonal phase by powder XRD in all cases, independently of the synthesis conditions employed. Nanoparticles were characterized by their size and morphology by TEM. We used the HgI 2 nanostructures to obtain a pellet by applying 0.7 GPa of pressure at room temperature. The pellet was then used to construct the detector, and we studied the electrical properties of the detector and its response to 241 Am sources of different exposure rates. The resistivity and signal-to-noise ratio obtained are of the order of those reported for HgI 2 detectors assembled with monocrystals. The results obtained in this work encourage us to work further on this topic, improving the method, scaling the detector’s size and studying its spectrometric grade. (paper)

  5. High energy proton-induced radioactivity in HgI2 crystals

    International Nuclear Information System (INIS)

    Porras, E.; Ferrero, J.L.; Sanchez, F.; Ruiz, J.A.; Lei, F.

    1995-01-01

    Mercuric iodide (HgI 2 ) semiconductor crystals are generating a lot of interest as room temperature solid state detectors for hard X-ray astronomy observations. For these applications one of the most important background sources is the cosmic proton induced radioactivity in the detector material. In order to study this background noise contribution a 1x1x1 cm HgI 2 crystal was irradiated with high energy protons. The resulting long-lived unstable isotopes and their production rates have been identified and compared with Monte Carlo simulations. ((orig.))

  6. ??????????? ????????? ???????????? ???????????? NH4X (?=??,?1) ??? ??????????? CdxHgi-xTe ??????? ???????? ???????????? ???????

    OpenAIRE

    ??????, ?. ?.; ?????????, ?. ?.; ???????, ?. ?.; ?????????, ?. ?.; ?????????, ?. ?.

    2004-01-01

    ?? ?????? ??????????? ?????????? ???????????? ?????? ??????? ???? ??????? CdxHgi_xTe-Hg-NH4Br ??? ??????? ?????? Hg ? ????????? ?????????? 560-860? ? ??????????? ?????? ?? = 103-=-105 ?? ????????? ????????, ??? ??????? ???????? ????? ? ??????????????? ??????, ????? ? ?????? - CdBr2, Hg, ??2. ??? ????????? ??????? ??????? ???????????? CdxHgi_xTe ??????? ? = 0.2; 0.3; 0.4 ?? ????????? ??? ??? ? ??? ?????????? ??????? ???????? ??????? (??? ?????? ?????? ????? ? ???????) ????????? ??????????? ???...

  7. Dielectric properties of nanophase Ag2HgI4 and Ag2HgI4–Al2O3 ...

    Indian Academy of Sciences (India)

    Unknown

    ions (Leute and Rusche 1981). Many authors (Neubert ... The particles of Ag2HgI4 were separated from the suspen- sion, washed ... Capacitance (C) and dielectric loss (tan δ) were measured using a .... the energy of formation of lattice defects. Since the ... in fast-ion conductors is interpreted in terms of random hopping of ...

  8. New thermal neutron solid-state electronic detector based on HgI2 crystals

    International Nuclear Information System (INIS)

    Melamud, M.; Burshtein, Z.

    1983-07-01

    We describe the development of a new solid-state electronic neutron detector, based on HgI 2 single crystals. Incident neutrons are absorbed in high neutron absorbing foils, such as cadmium or gadolinium, which are placed in front of a HgI 2 detector. Gamma rays, emitted as a result of the neutron absorbtion, are then absorbed in the HgI 2 , generating free charge carriers, which are collected by the electric field. The advantage of this system lies in it's manufacturing simplicity, low weight and small physical dimensions, compared to gas-filled conventional neutron detectors. The disadvantage is that the system does not discriminate between gamma rays and neutrons. A method to minimize this disadvantage is pointed out. It is as well possible to count neutrons by direct exposure of the HgI 2 to neutrons. The neutron-to-gamma transformation in that case takes place by the material nuclei themselves. This method, however, is impractical due to the interference of delayed radioactivity whose origin are 129 I nuclei. They are generated from 128 I by absorbing a neutron, and decay with a 25 min half lifetime involving gamma emissions. (author)

  9. Phase transition study in a [Cu2 HgI4:0⋅xAgI] mixed composite system

    Indian Academy of Sciences (India)

    Administrator

    Diffraction, thermal analysis of compound, Ag2HgI4,. Cu2HgI4, Tl2HgI4 ... nitrogen atmosphere (200 ml/min) at a heating rate of. 5°C per min and a ..... Bates J B and Farington G C 1981 Proceedings of the interna- tional conference on fast ...

  10. Electronic structure and optical properties of Cs2HgI4: Experimental study and band-structure DFT calculations

    Science.gov (United States)

    Lavrentyev, A. A.; Gabrelian, B. V.; Vu, V. T.; Shkumat, P. N.; Myronchuk, G. L.; Khvyshchun, M.; Fedorchuk, A. O.; Parasyuk, O. V.; Khyzhun, O. Y.

    2015-04-01

    High-quality single crystal of cesium mercury tetraiodide, Cs2HgI4, has been synthesized by the vertical Bridgman-Stockbarger method and its crystal structure has been refined. In addition, electronic structure and optical properties of Cs2HgI4 have been studied. For the crystal under study, X-ray photoelectron core-level and valence-band spectra for pristine and Ar+-ion irradiated surfaces have been measured. The present X-ray photoelectron spectroscopy (XPS) results indicate that the Cs2HgI4 single crystal surface is very sensitive with respect to Ar+ ion-irradiation. In particular, Ar+ bombardment of the single crystal surface alters the elemental stoichiometry of the Cs2HgI4 surface. To elucidate peculiarities of the energy distribution of the electronic states within the valence-band and conduction-band regions of the Cs2HgI4 compound, we have performed first-principles band-structure calculations based on density functional theory (DFT) as incorporated in the WIEN2k package. Total and partial densities of states for Cs2HgI4 have been calculated. The DFT calculations reveal that the I p states make the major contributions in the upper portion of the valence band, while the Hg d, Cs p and I s states are the dominant contributors in its lower portion. Temperature dependence of the light absorption coefficient and specific electrical conductivity has been explored for Cs2HgI4 in the temperature range of 77-300 K. Main optical characteristics of the Cs2HgI4 compound have been elucidated by the first-principles calculations.

  11. Improved fabrication of HgI2 nuclear radiation detectors by machine-cleaving

    International Nuclear Information System (INIS)

    Levi, A.; Burger, A.; Schieber, M.; Vandenberg, L.; Yellon, W.B.; Alkire, R.W.

    1982-01-01

    The perfection of machine-cleaved sections from HgI 2 bulk crystals was examined. The perfection of the machine-cleaved sections as established by gamma diffraction rocking curves was found to be much better than the perfection of hand-cleaved sections or as grown thin platelets, reaching a perfection similar to that of the wire-sawn sections of HgI 2 . A correlation between the perfection and the thickness of the machine-cleaved section was also found, i.e., the thicker the cleaved-section the more perfect it is. The reproducibility of the fabrication was significantly improved by using machine cleaving in the process of fabrication. Large single crystals of HgI 2 weighing 20 to 200 g, can be grown from the vapor phase using the TOM Technique. In order to fabricate nuclear radiation detectors from these single crystals, thin sections of about 0.4 to 0.8 mm thickness have to be prepared. Up till now, the state-of-the-art of fabricating HgI 2 nuclear radiation detectors involved two methods to get thin sections from the large single crystals: (1) hand-cleaving using a razor-blade and (2) solution wire sawing. The chemical wire sawing method involves a loss of about 50% of the crystal volume and is usually followed by a chemical polishing process which involves a significant loss of volume of the original volume. This procedure is complicated and wasteful. The traditional fabrication method, i.e., hand-cleaving followed by rapid nonselective chemical etching, is simpler and less wasteful

  12. Designing and making of a tool used for measurements by X fluorescence using HgI2 detectors

    International Nuclear Information System (INIS)

    Liu-Xu, X.

    1994-10-01

    A new measuring apparatus by X fluorescence based on a HgI 2 detector, operating at room temperature is presented. The principal properties of HgI 2 are outlined. A computer code designed for this apparatus is developed. Some experimental results are given to illustrate the performances of the device. (author). 67 refs., 117 figs., 7 tabs

  13. Field-portable high-resolution EDXRF analysis with HgI2-detector-based instrumentation

    International Nuclear Information System (INIS)

    Berry, P.F.; Little, S.R.; Voots, G.R.

    1992-01-01

    Energy dispersive x-ray fluorescence (EDXRF) analysis is well known for its efficient use of x-ray detector technology for simultaneous multielement determination. Low-intensity excitation, such as from a radioisotope source, can thus be employed and has enabled the design of many types of truly portable EDXRF instrumentation. Portable design, however, has not been without significant compromise in analytical performance because of the limited x-ray resolving power of prior detection methods, except by the use of a cryogenically operated detector. The developments we refer to stem from the use of a comparatively new x-ray detection device fabricated from mercuric iodide (HgI 2 ). For this detector, only a modest degree of cooling is required to achieve an energy resolution of > 300 eV. Two field-portable instrument designs of different hand-held measurement probe configurations are available that have applications for industrial quality assurance and environmental screening

  14. Monocrystal growth and characterization of HgI2 semiconductor compound for using in X and gamma spectrometries

    International Nuclear Information System (INIS)

    Faria, L.O.

    1987-01-01

    Mercury Iodide (HgI 2 ) platelets were grown from the vapor phase in the presence of polymers. These platelets are convenient to be used as room temperature operating semiconductor radiation detectors. Experiments demonstrate that the growth of platelets depends on a two-stage mass transport instead of depending on just one, as it has been thought. HgI 2 platelets 30 mm 2 large and 90 μm thick were obtained in a sealed evacuated fused quartz tube and were characterized by etch pit density measurements. (author) [pt

  15. A comparative study on surface morphology from the HgI2 semiconductors prepared by different techniques

    International Nuclear Information System (INIS)

    Martins, Joao F.T.; Ferraz, Caue de M.; Santos, Robinson A. dos; Mesquita, Carlos H. de; Hamada, Margarida M.

    2013-01-01

    The impurity effect in the surface morphology quality of HgI 2 crystals was evaluated, aiming a future application of these crystals as room temperature radiation semiconductor detector. The crystals were purified and grown by two techniques: (1) physical vapor transport (PVT) and (2) saturated solution from dimethylsulfoxide (DMSO) complexes. Systematic measurements were carried out for determining the stoichiometry, structure orientation, surface morphology and impurity of the crystal. The best quality of surface morphology was found for the crystals purified and grown by the PVT technique. Significant decrease in the impurity concentration was found, purifying the crystal by means of two successive growths by the PVT technique, while a Si contamination in the HgI 2 crystal was observed, during its growth by the DMSO method. Thus, for DMSO technique was not possible to identify the peaks of the other trace elements present as impurities in the PVT crystal, due to the high intensity of the Si peak in the DMSO crystal. It was demonstrated the impurities affect significantly the surface morphology quality from the HgI 2 crystal. Key Words: Semiconductor crystal, Radiation detector, Mercury Iodide crystal, surface morphology. (author)

  16. Growth and characterization of monocrystals from HgI2 semiconductor compound for using in X and gamma spectroscopy

    International Nuclear Information System (INIS)

    Faria, L.O. de.

    1987-09-01

    Mercury Iodide (HgI 2 ) platelets were grown from the vapor phase in the presence of polymers. These platelets are convenient to be used as room temperature operating semiconductor radiation detectors. Experiments demonstrate that the growth of platelets depends on a two-stage mass transport instead of depending on just one, as it has been thought. HgI 2 platelets 30 mm 2 large and 90 μm thick were obtained in a sealed evacuated fused quartz tube and were characterized by etch pit density measurements. (author)

  17. Radiometric and dosimetric characteristics of HgI2 detectors

    International Nuclear Information System (INIS)

    Zaletin, V.M.; Krivozubov, O.V.; Torlin, M.A.; Fomin, V.I.

    1988-01-01

    The characteristics of HgI 2 detectors in x-ray and gamma detection in applications to radiometric and dosimetric monitoring and as portable instruments for such purposes was considered. Blocks with mosaic and sandwich structures were prepared and tested against each other and, for comparative purposes, against CdTe detectors for relative sensitivities at various gamma-quanta energies. Sensitivity dependencies on gamma radiation energy were plotted for the detector materials and structures as were current dependencies on the dose rate of x rays. Results indicated that the mercury iodide detectors could be used in radiometric and dosimetric measurements at gamma quantum energies up to and in excess of 1000 KeV

  18. Low-temperature photoluminescence of detector-grade HgI2

    International Nuclear Information System (INIS)

    Merz, J.L.; Wu, Z.L.; van den Berg, L.; Schnepple, W.F.

    1981-01-01

    The low-temperature photoluminescence of HgI 2 is reported. Three main luminescence bands are observed, with peaks at approx. 2.30, 2.20, and 2.00 eV at 77 K. At 4.2 K, the highest energy peak shows considerable structure. The temperature dependence of these lines indicates both free and bound exciton recombination, and very small exciton binding energies (approx. 3 to 5 MeV) have been estimated. A comparison of the results of sublimation and doping experiments suggests that the lowest energy band may be related to impurities, whereas the middle-energy band is related to I content. The two strongest bound exciton lines comprising the high-energy band show systematic correlations with the middle-energy, I-related band. Further correlations between these spectral features and the performance of nuclear radiation detectors fabricated from these samples are also noted. The temperature coefficient of the band gap is estimated from the spectral shift of luminescence lines to be approximately -1.13 x 10 -4 eV/K between 32 K and 45 K

  19. Influence of temperature upon dislocation mobility and elastic limit of single crystal HgI2

    International Nuclear Information System (INIS)

    Milstein, F.; Farber, B.; Kim, K.; van den Berg, L.; Schnepple, W.

    1982-01-01

    The practical importance of studying mechanical properties and dislocation structure of HgI 2 is reviewed briefly. Specifically, the performance of single crystal HgI 2 radiation detectors is evidently sensitive to crystalline imperfections; the dislocation structure, in turn, can be altered during detector fabrication, depending upon the mechanical properties of the crystal and the stresses to which the crystal is subjected. The influence of temperature upon dislocation mobility and plasticity in vapor-grown crystals of mercuric iodide is examined. Dislocation mobiity is determined by measuring the lengths of the longest arms of dislocation etch pit rosettes on (001) surfaces following microhardness indentation and chemical etch. Measurements were made in the range from room temperature to the phase transition temperature of 127 0 C. Dislocation mobility was found to be an increasing function of temperature, with the effect accelerating as the phase transition is approached. Increasing temperature was also found to lower the critical resolved shear stress for plastic deformation on slip on (001) planes. In these contexts, the vapor-grown crystals are clearly softer at their elevated growth temperatures. The results are discussed in terms of a dislocation model involving soft and hard glide dislocations

  20. Performance of room temperature mercuric iodide (HgI2) detectors in the ultra low energy x-ray region

    International Nuclear Information System (INIS)

    Dabrowski, A.J.; Iwanczyk, J.S.; Barton, J.B.; Huth, G.C.; Whited, R.; Ortale, C.; Economou, T.E.; Turkevich, A.L.

    1980-01-01

    Performance of room temperature mercuric iodide x-ray spectrometers has been recently improved through new fabrication techniques and further development of low noise associated electronic systems. This progress has extended the range of measurements to the ultra low energy x-ray region at room temperature. This paper reports the study of the effect of contact material on the performance of HgI 2 detectors in the low energy x-ray region

  1. 'RIG'- surgical gamma probe for early breast cancer detection

    International Nuclear Information System (INIS)

    Walinjkar, P.B.; Singh, Gursharan; Kumar, Umesh; Pendharkar, A.S.; Choudhary, P.S.

    2004-01-01

    Breast cancer is one of the most common cancers in women, which if detected in early stage can be effectively treated and cured. Early detection is carried out by collecting a sentinel lymph node (SLN) and testing it for cancer. The surgical gamma probe is a hand-held device used in the localization of SLN. It enables the localization of the active node. Isotope Applications Division, BARC has developed indigenously a RIG Surgical Gamma Probe in consultation with the doctors from Rajiv Gandhi Cancer Institute and Research Centre, New Delhi. The system consists of microcomputer-based gamma counting system that displays the number of pulses detected by the probe in counts per second and has an audible signal in direct correlation with the count density. The detector probe is based on the scintillation detector housed in a stainless steel housing with lead collimator. The physical parameters are a high sensitivity of 5000 cps/MBq at probe tip with good spatial resolution. The performance of this probe was clinically evaluated on the basis of spatial resolution and accuracy to detect the active node. (author)

  2. Correlations between plastic deformation parameters and radiation detector quality in HgI2

    International Nuclear Information System (INIS)

    Georgeson, G.; Milstein, F.; California Univ., Santa Barbara

    1989-01-01

    Mercuric iodide radiation detectors of various grades of quality were subjected to shearing forces in the (001) crystallographic planes using a specially designed micromechanical shear testing fixture. Experimental measurements were made of (001) shear stress versus shear strain. Each of the stress-strain curves was described by two empirically determined deformation parameters, s 0 and σ, where s 0 is a measure of 'bulk yielding' and σ indicates the 'sharpness of yielding' during plastic deformation. It was observed that the deformation parameters of many HgI 2 single crystal samples fit the relation s 0 =8σ 2/3 and that significant deviation from this relation, with s 0 >8σ 2/3 , indicates poor detector quality. Work hardening by prior plastic deformation was also found to cause s 0 to depart (in an increasing manner) from the 8σ 2/3 relation. For good quality material that has not previously been plastically deformed, the deformation parameter s c =s 0 -2σ<19 psi; this parameter can be interpreted as the 'onset of plastic yielding'. The results are discussed in terms of dislocation mechanisms for plastic deformation, work hardening, and recovery of work hardening. (orig.)

  3. Analysis of HgI2 and PbI2 crystals and detectors by particle-induced x-ray emission (PIXE) and ion backscattering spectroscopy (IBS)

    International Nuclear Information System (INIS)

    Bench, G.S.; Heikkinen, D.W.; Antolak, A.J.; Morse, D.H.; Pontau, A.E.; James, R.B.; David, D.C.; Burger, A.; Van Den Berg, L.

    1993-03-01

    The Ion Micro-Analysis Group (IMAG) in Livermore conducts quantitative trace elemental analysis with PIXE and depth profiling with IBS using an MeV ion microbeam. The system has the capability to produce two-dimensional trace element and IBS images. PIXE analyses have been conducted on HgI 2 and PbI 2 crystals and detector materials in order to identify and quantify near surface trace contaminants. IBS measurements have been conducted to investigate elemental depth distributions in various materials. The results of measurements on several different samples are reported and a discussion of factors affecting quantitative in vacuo microanalysis of these materials is presented

  4. Radioguided surgery: First experiences with surgical gamma probe

    International Nuclear Information System (INIS)

    Vereb, M.; Bakala, J.

    2004-01-01

    Full text: Thanks to the International Atomic Energy Agency and co-operation of the Nuclear Regulatory Authority of the Slovak Republic - International and Public Relations Division, sentinel lymph node detection has been introduced in one of the regional hospitals in Slovakia. Surgical Gamma Probe, the equipment needed for this has been made available. IAEA first of all helped in organizing a workshop on Scintimammography, Sentinel Lymph Node Detection and Intra-Operative Surgical Probe in Breast Cancer, in April 2002. Education of specialists - surgeons, oncologists, and pathologists and of course radiologists helped them to better understand the subject visa-vis nuclear medicine techniques. We also started the sentinel node detection following the two-days protocol. A 57 years old female with newly detected breast carcinoma in right breast, with positive mammography was investigated. Axillary lymph nodes were not palpable. Tc-99m Nanocoll, with particles size ranging 4-100 nm, was administered, 75 MBq peritumorally + 75 MBq subdermally and a dynamic lymphoscintigraphy was acquired which showed migration of the radiotracer. Static views (after 120 min.) demonstrated 4 sentinel lymph nodes in the right axilla. No lymph node was seen in the internal mammary or left axillary region. Next day before operation about 2 ml of patten blue dye was injected around the tumor and breast was compressed for about 10 min. Identification of sentinel lymph node was done with the help of surgical gamma probe and blue tinting. We found 6 nodes, first two were not really sentinel, but they were blue. A breast conservation surgery with standard axillary lymphadenectomy was performed. Pathology revealed invasive ductal carcinoma. We understand the need to establish an algorithm of examination and treatment of patients with newly diagnosed breast carcinoma. This technology requires teamwork of surgeon, nuclear medicine physician and pathologist. Regarding radiation exposure which every

  5. Utility of an intraoperabive gamma probe in the surgical management of secondary or tertiary hyperparathyroidism

    NARCIS (Netherlands)

    Jorna, Francisca H.; Jager, Pieter L.; Lemstra, Clara; Wiggers, Theo; Stegeman, Coen A.; Plukker, John T. M.

    BACKGROUND: In primary hyperparathyroidism the gamma probe is effective, but its role in secondary hyperparathyroidism is unclear. We investigated the utility of the probe in the surgical management of secondary and tertiary hyperparathyroidism. METHODS: The value of the probe in guiding resection

  6. Development of voltage sensitivity preamplifier to application in radioguided surgical probe

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da; Rela, Paulo Roberto; Hamada, Margarida Mizue

    2005-01-01

    The methods of nuclear medicine are increasing used to complement standard diagnostic examinations. Some of these are radioguided detection of the sentinel lymph node (SN) and the radioguided localization of occult lesions. The SN technique is used in a small-size breast carcinoma and involves the identification, removal and immediate histological examination. Specifically, particles of colloidal human serum albumin are labelled with low activities of 99m Tc and are inoculated into the breast lesion or close in the case of SN biopsy. Subsequently, a hand-held gamma-ray detecting probe with reduced dimensions is used to locate the lesion or the SN as a hot spot and guide its surgical removal. Many techniques can be used for gamma-ray probes development. Gamma photons can be either directly detected via high atomic numbers semiconductors detectors or indirect detection, as scintillator crystal converts gamma photons into light photons. In all of them, the preamplifier is used as close as possible to the detector for obtaining a good energy resolution and due to the necessary small probe dimension, the preamplifier must have reduced size. The commercial preamplifiers are not small enough to be assembled inside the probe. It was developed a not usually preamplifier configuration for high-resolution spectroscopy energy, adequate in size to be set up in gamma-ray probes. This tension preamplifier can be split between the gamma-ray probe and the read out unit. Due to this configuration the effective size required inside the probe was reduced. The results and the probe assembling are showed in this work. (author)

  7. Hemoglobin glycation index as a useful predictor of therapeutic responses to dipeptidyl peptidase-4 inhibitors in patients with type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Yu-Wei Chen

    Full Text Available A high hemoglobin glycation index (HGI and glycated hemoglobin (HbA1c level are associated with greater inflammatory status, and dipeptidyl peptidase-4 (DPP-4 inhibitors can suppress inflammation. We aimed to evaluate the relationship between HGI and the therapeutic effect of DPP-4 inhibitors.This retrospective cohort study followed 468 patients with type 2 diabetes receiving DPP-4 inhibitor treatment for 1 year. Estimated HbA1c was calculated using a linear regression equation derived from another 2969 randomly extracted patients with type 2 diabetes based on fasting plasma glucose (FPG level. The subjects were divided into two groups based on HGI (HGI = observed HbA1c - estimated HbA1c. Mixed model repeated measures were used to compare the treatment efficacy after 1 year in patients with a low (HGI<0, n = 199 and high HGI (HGI≧0, n = 269.There were no significant group differences in mean changes of FPG after 1 year (-12.8 and -13.4 mg/dL in the low and high HGI groups, respectively. However, the patients with a high HGI had a significantly greater reduction in HbA1c from baseline compared to those with a low HGI (-1.9 versus -0.3% [-20.8 versus -3.3 mmol/mol]. Improvements in glycemic control were statistically significantly associated with the tested DPP-4 inhibitors in the high HGI group (-2.4, -1.4, -1.2 and -2.2% [-26.2, -15.3, -13.1 and -24.0 mmol/mol] for vildagliptin, linagliptin, saxagliptin and sitagliptin, respectively but not in the low HGI group.The HGI index derived from FPG and HbA1c may be able to identify who will have a better response to DPP-4 inhibitors.

  8. Periodontal probing of an impacted tooth recovered through a surgical-orthodontic approach: a case report.

    Science.gov (United States)

    Dinoi, Maria Teresa; Lacarbonara, Mariano; Dimartino, Salvatore; Monaco, Annalisa; Marzo, Giuseppe

    2014-01-27

    The aim of this work was to assess the periodontal support of a central upper incisor recovered through a surgical-orthodontic approach compared to the spontaneously erupted contralateral incisor. This case study describes an 8-year-old Caucasian female with an impacted upper right central incisor. Surgical-orthodontic treatment was performed to reset the impacted dental element in the arch. Periodontal probing was performed of all sites (mesio-buccal, central-buccal, disto-buccal, mesio-palatal, central-palatal and disto-palatal) of the recovered impacted tooth and the contralateral tooth. The results were compared to determine whether the treated element showed signs of periodontal injury. Most of the probing results on both her right and left incisors gave values of approximately 3mm, which were not considered pathological. Both dental elements had adequate and physiological osseous attachments.

  9. Study of the pseudo-ternary Ag2SAs2S3HgI2 vitreous system

    Science.gov (United States)

    Boidin, R.; Le Coq, D.; Cuisset, A.; Hindle, F.; Brubach, J.-B.; Michel, K.; Bychkov, E.

    2013-03-01

    Chalcogenide alloys in the Ag2SAs2S3HgI2 pseudo-ternary system were synthesized and their vitreous nature was verified by X-ray diffraction. The glass transition and crystallization temperatures (Tg and Tc), the density (d), and the total electrical conductivity (σ) were measured for all samples of three series, A, B, and C corresponding to (Ag2S)50-x/2(As2S3)50-x/2(HgI2)x, (Ag2S)y(As2S3)80-y(HgI2)20 and (Ag2S)z(As2S3)50(HgI2)50-z, respectively. The maximum of Tg was approximately 160 °C for glasses with low HgI2 content whereas the maximum of density (5.75 g cm-3) was obtained for the sample in the B-series with the highest Ag2S concentration (z=60 mol%). This composition also possesses the highest conductivity at 298 K (σ298 K≈10-3 S cm-1). Unexpectedly the conductivity of the A-series samples was observed to decrease as a function of the Ag2S content. The far-infrared transmission in the 100-600 cm-1 window range (3.3-18.2 THz, 100-16.6 μm) was also given for a few glass compositions highlighting the strong influence of the HgI2 content.

  10. Development of surgical gamma probes with TlBr semiconductors and CsI(Tl) scintillators crystals

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da

    2006-01-01

    Radio guided surgery, using probes with radiation detectors, has been prominence in the medical area in the last decade. This technique consists in injecting a radioactive substance to concentrate in tumour and assist the localization during the surgical procedure. The radio guided surgeries allowing the identification of lymph node has revolutioned the behavior of tumour in initial stadium when are being spread by lymphatic way. The conditions imposed to the surgery due the proximity between some lymph nodes, demands of the probes, a small diameters and capacity of individual identification of these lymph nodes radiolabelled by a specific tracer. The international market supplies these probes with CdTe semiconductors and scintillators, but there is some time lack a promptly technical assistance in the Brazilian market. This work developed probes with national technology, using CsI(Tl) scintillators crystals and, in substitution to CdTe crystals semiconductors, the TlBr crystal, that is a new semiconductor detector in a world-wide development, with advantages in relation to the CdTe. Both crystals have been grown in IPEN. All the necessary electronics, specially, the preamplifier, that was also a restrictive factor for development of these types of probe in the country, have been developed with components found in the national market. Systematic measures of spatial resolution, spatial selectivity, maximum sensitivity and quality of the shielding have been carried the probes development. The results have shown that the probes, one with the CsI(Tl) crystal and another with TlBr semiconductor presented the requested performance in the international literature for radio guided probes. (author)

  11. PET-Probe: Evaluation of Technical Performance and Clinical Utility of a Handheld High-Energy Gamma Probe in Oncologic Surgery.

    Science.gov (United States)

    Gulec, Seza A; Daghighian, Farhad; Essner, Richard

    2016-12-01

    Positron emission tomography (PET) has become an invaluable part of patient evaluation in surgical oncology. PET is less than optimal for detecting lesions PET-positive lesions can be challenging as a result of difficulties in surgical exposure. We undertook this investigation to assess the utility of a handheld high-energy gamma probe (PET-Probe) for intraoperative identification of 18 F-deoxyglucose (FDG)-avid tumors. Forty patients underwent a diagnostic whole-body FDG-PET scan for consideration for surgical exploration and resection. Before surgery, all patients received an intravenous injection of 7 to 10 mCi of FDG. At surgery, the PET-Probe was used to determine absolute counts per second at the known tumor site(s) demonstrated by whole-body PET and at adjacent normal tissue (at least 4 cm away from tumor-bearing sites). Tumor-to-background ratios were calculated. Thirty-two patients (80%) underwent PET-Probe-guided surgery with therapeutic intent in a recurrent or metastatic disease setting. Eight patients underwent surgery for diagnostic exploration. Anatomical locations of the PET-identified lesions were neck and supraclavicular (n = 8), axilla (n = 5), groin and deep iliac (n = 4), trunk and extremity soft tissue (n = 3), abdominal and retroperitoneal (n = 19), and lung (n = 2). PET-Probe detected all PET-positive lesions. The PET-Probe was instrumental in localization of lesions in 15 patients that were not immediately apparent by surgical exploration. The PET-Probe identified all lesions demonstrated by PET scanning and, in selected cases, was useful in localizing FDG-avid disease not seen with conventional PET scanning.

  12. Performance of novel materials for radiation detection: Tl3AsSe3, TlGaSe2, and Tl4HgI6

    International Nuclear Information System (INIS)

    Kahler, D.; Singh, N.B.; Knuteson, D.J.; Wagner, B.; Berghmans, A.; McLaughlin, S.; King, M.; Schwartz, K.; Suhre, D.; Gotlieb, M.

    2011-01-01

    In this paper we report on the electrical characteristics of three novel ternary compounds, Tl 3 AsSe 3 (TAS), TlGaSe 2 (TGS), and Tl 4 HgI 6 (THI), pertaining to their use as radiation detectors. The details for growth and material characterization are not presented. A semiconductor based gamma ray detector requires a material with high Z, high density, high resistivity, appropriate bandgap (1.5-2 eV), low energy/electron-hole pair, and a high μτ product. CZT is currently the best semiconductor material for room temperature gamma ray spectroscopy; however, it is extremely difficult to produce large volumes of detector grade material, making it expensive and in limited supply. DNDO/DHS began searching for other materials that might perform as well as CZT but be easier to grow and in the end lower the cost. For this purpose, we investigated the above three materials as possible replacements for CZT as gamma ray detectors. The bulk resistivity, I-V curves, X-ray response, and gamma ray response measurements for doped and undoped crystals are presented and discussed. TAS shows good X-ray and gamma ray response, but has poor resistivity, which results in large dark current and poor spectral response. TGS has good resistivity, but shows poor X-ray and gamma ray response. THI has excellent resistivity, shows some X-ray and gamma ray response, and has great potential as a gamma ray detector.

  13. Dual in vivo Photoacoustic and Fluorescence Imaging of HER2 Expression in Breast Tumors for Diagnosis, Margin Assessment, and Surgical Guidance

    Directory of Open Access Journals (Sweden)

    Azusa Maeda

    2015-01-01

    Full Text Available Biomarker-specific imaging probes offer ways to improve molecular diagnosis, intraoperative margin assessment, and tumor resection. Fluorescence and photoacoustic imaging probes are of particular interest for clinical applications because the combination enables deeper tissue penetration for tumor detection while maintaining imaging sensitivity compared to a single optical imaging modality. Here we describe the development of a human epidermal growth factor receptor 2 (HER2-targeting imaging probe to visualize differential levels of HER2 expression in a breast cancer model. Specifically, we labeled trastuzumab with Black Hole Quencher 3 (BHQ3 and fluorescein for photoacoustic and fluorescence imaging of HER2 overexpression, respectively. The dual-labeled trastuzumab was tested for its ability to detect HER2 overexpression in vitro and in vivo. We demonstrated an over twofold increase in the signal intensity for HER2-overexpressing tumors in vivo, compared to low–HER2-expressing tumors, using photoacoustic imaging. Furthermore, we demonstrated the feasibility of detecting tumors and positive surgical margins by fluorescence imaging. These results suggest that multimodal HER2-specific imaging of breast cancer using the BHQ3-fluorescein trastuzumab enables molecular-level detection and surgical margin assessment of breast tumors in vivo. This technique may have future clinical impact for primary lesion detection, as well as intraoperative molecular-level surgical guidance in breast cancer.

  14. Investigation into the applicability of Bond Work Index (BWI) and Hardgrove Grindability Index (HGI) tests for several biomasses compared to Colombian La Loma coal

    OpenAIRE

    Williams, Orla; Eastwick, Carol; Kingman, Sam; Giddings, Donald; Lormor, Stephen; Lester, Edward

    2015-01-01

    With increasing quantities of biomass being combusted in coal fired power stations, there is an urgent need to be able to predict the grindability of biomass in existing coal mills, but currently no standard biomass grindability test exists. In this study, the applicability of the Hardgrove Grindability Index (HGI) and Bond Work Index (BWI) as standard grindability tests for biomass were investigated for commercially sourced wood pellets, steam exploded pellets, torrefied pellets, sunflower p...

  15. CO{sub 2} geothermal heat probe - Phase 2; CO{sub 2}-Erdwaermesonde - Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Grueniger, A.; Wellig, B.

    2009-12-15

    In this project the fluid dynamics and thermodynamics inside a CO{sub 2} geothermal heat probe have been investigated. The functionality of such a probe, which works like a thermosyphon, was analyzed by means of a simulation model in MATLAB. The model couples the behaviour inside the heat probe with the heat conduction in the earth. A parameter study revealed that the self-circulation character of such a probe leads to flattening of the vertical earth temperature profile near the probe and, hence, leads to more uniform heat removal along the probe. The circulation of CO{sub 2} even goes on when the heat pump is off. This might be advantageous for the regeneration phase. The heat transfer resistance of the evaporating CO{sub 2} film flowing down the probe wall is very small compared to the conduction resistance of the earth. Therefore, no difference has been found between the performances of a conventional heat pipe and a configuration where the liquid phase injection is distributed on different height stages along the probe. It is estimated that the seasonal performance factor of heat pumps can be improved by 15-25% with a CO{sub 2} geothermal heat probe. The main advantage is that the heat transfer to the evaporator of the heat pump (condensation of CO{sub 2} / evaporation of refrigerant) is much more efficient than in a conventional brine probe without phase change. Furthermore, no circulation pump is needed. (authors)

  16. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  17. Design and testing of microfabricated surgical tools for large animal probe insertion

    Energy Technology Data Exchange (ETDEWEB)

    Jorgensen, Shelly [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-08-05

    Neural probes provide therapeutic stimulation for neuropsychiatric disorders or record neural activity to investigate the workings of the brain. Researchers utilize 6 mm long temporary silicon stiffeners attached with biodissolvable adhesive to insert flexible neural probes into rat brains, but increasing the probe length fivefold makes inserting large animal probes a significant challenge because of an increased potential for buckling. This study compared the insertion success rates of 6 mm and 30 mm long silicon stiffeners that were 80 μm wide and 30 μm thick, and ascertained the material thickness and modulus of elasticity that would provide successful insertion for a 30 mm probe. Using a microdrive, stiffeners were inserted into an agarose brain phantom at controlled insertion speeds while being video-recorded. Twenty-five percent of the 30 mm silicon stiffeners fully inserted at speeds approximately four times higher than the target rate of 0.13 mm/s, while 100 percent of the 6 mm silicon stiffeners inserted successfully at target speed. Critical buckling loads (Pcr) were calculated for the 6 mm and 30 mm silicon stiffeners, and for 30 mm diamond and tungsten stiffeners, with thicknesses varying from 30-80 μm. Increasing the thickness of the material by 10 μm, 20 μm and 30 μm improved the Pcr by 2.4, 4.7 and 8.2 times, respectively, independent of the material, and substituting diamond for silicon multiplied the buckling capacity by 5.0 times. Stiffeners made of silicon for large animal probe insertion are not strong enough to withstand buckling upon insertion without a significant increase in thickness. Replacing silicon with diamond and increasing the thickness of the stiffener to 50 μm would afford a stiffener with the same Pcr capacity as the 6 mm silicon stiffener that had a 100 percent insertion success rate. Experiments should continue with diamond to determine a minimum thickness that will ensure successful

  18. NASA SMART Probe: Breast Cancer Application

    Science.gov (United States)

    Mah, Robert W.; Norvig, Peter (Technical Monitor)

    2000-01-01

    There is evidence in breast cancer and other malignancies that the physiologic environment within a tumor correlates with clinical outcome. We are developing a unique percutaneous Smart Probe to be used at the time of needle biopsy of the breast. The Smart Probe will simultaneously measure multiple physiologic parameters within a breast tumor. Direct and indirect measurements of tissue oxygen levels, blood flow, pH, and tissue fluid pressure will be analyzed in real-time. These parameters will be interpreted individually and collectively by innovative neural network techniques using advanced intelligent software. The goals are 1) develop a pecutaneous Smart Probe with multiple sensor modalities and applying advanced Information Technologies to provide real time diagnostic information of the tissue at tip of the probe, 2) test the percutaneous Smart Probe in women with benign and malignant breast masses who will be undergoing surgical biopsy, 3) correlate probe sensor data with benign and malignant status of breast masses, 4) determine whether the probe can detect physiologic differences within a breast tumor, and its margins, and in adjacent normal breast tissue, 5) correlate probe sensor data with known prognostic factors for breast caner, including tumor size, tumor grade, axillary lymph node metastases, estrogen receptor and progesterone receptor status.

  19. Surgical pathology report defects: a College of American Pathologists Q-Probes study of 73 institutions.

    Science.gov (United States)

    Volmar, Keith E; Idowu, Michael O; Hunt, Jennifer L; Souers, Rhona J; Meier, Frederick A; Nakhleh, Raouf E

    2014-05-01

    The rate of surgical pathology report defects is an indicator of quality and it affects clinician satisfaction. To establish benchmarks for defect rates and defect fractions through a large, multi-institutional prospective application of standard taxonomy. Participants in a 2011 Q-Probes study of the College of American Pathologists prospectively reviewed all surgical pathology reports that underwent changes to correct defects and reported details regarding the defects. Seventy-three institutions reported 1688 report defects discovered in 360,218 accessioned cases, for an aggregate defect rate of 4.7 per 1000 cases. Median institutional defect rate was 5.7 per 1000 (10th to 90th percentile range, 13.5-0.9). Defect rates were higher in institutions with a pathology training program (8.5 versus 5.0 per 1000, P = .01) and when a set percentage of cases were reviewed after sign-out (median, 6.7 versus 3.8 per 1000, P = .10). Defect types were as follows: 14.6% misinterpretations, 13.3% misidentifications, 13.7% specimen defects, and 58.4% other report defects. Overall, defects were most often detected by pathologists (47.4%), followed by clinicians (22.0%). Misinterpretations and specimen defects were most often detected by pathologists (73.5% and 82.7% respectively, P benchmarking data on report defects and defect fractions using standardized taxonomy.

  20. Surgical Non-Regenerative Treatments for Peri-Implantitis: a Systematic Review

    Directory of Open Access Journals (Sweden)

    Ausra Ramanauskaite

    2016-09-01

    Full Text Available Objectives: The purposes of the present study were 1 to systematically review the literature on the surgical non-regenerative treatments of peri-implantitis and 2 to determine a predictable therapeutic option for the clinical management of peri-implantitis lesions. Material and Methods: The study search was performed on primary database MEDLINE and EMBASE from 2005 until 2016. Sequential screenings at the title, abstract, and full-text levels were performed. Clinical human studies in the English language that had reported changes in probing depth (PD and/or bleeding on probing (BOP and/or radiologic marginal bone level changes after peri-implantitis surgical non-regenerative treatment at 6-month follow-up or longer were included accordingly PRISMA guidelines. Results: The first electronic and hand search resulted in 765 citations. From 16 full-text articles reviewed, 6 were included in this systematic review. Surgical non-regenerative methods were found to be efficient in reducing clinical parameters. BOP and PD values were significantly decreased following implantoplasty and systematic administration of antibacterials, but not after local application of chemical compounds or diode laser. Similarly, significant improvement in clinical and radiographic parameters was found only after implantoplasty compared with resective surgery alone. We found significant heterogeneity in study designs and treatments provided among the pooled studies. All of the studies revealed an unclear or high risk of bias. Conclusions: Surgical non-regenerative treatment of peri-implantitis was found to be effective to reduce the soft tissue inflammation and decrease probing depth. More randomized controlled clinical trials are needed to assess the efficacy of surgical non-regenerative therapy of peri-implantitis.

  1. 21 CFR 886.4350 - Manual ophthalmic surgical instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual ophthalmic surgical instrument. 886.4350 Section 886.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suturing needle, lachrymal probe, trabeculotomy probe, cornea-sclera punch, ophthalmic retractor...

  2. Association Between Coronary Artery Calcification and the Hemoglobin Glycation Index: The Kangbuk Samsung Health Study.

    Science.gov (United States)

    Rhee, Eun-Jung; Cho, Jung-Hwan; Kwon, Hyemi; Park, Se Eun; Park, Cheol-Young; Oh, Ki-Won; Park, Sung-Woo; Lee, Won-Young

    2017-12-01

    The hemoglobin glycation index (HGI) is known to be correlated with the risk for cardiovascular disease. To analyze the association between incident coronary artery calcification (CAC) and the changes in HGI among participants without diabetes, over 4 years. A retrospective study of 2052 nondiabetic participants in whom the coronary artery calcium score was measured repeatedly over 4 years, as part of a health checkup program in Kangbuk Samsung Hospital in Korea, and who had no CAC at baseline. The HGI was defined as the difference between the measured and predicted hemoglobin A1c (HbA1c) levels. A total of 201 participants developed CAC after 4 years, and the mean baseline HGI was significantly higher in those patients. The incidence of CAC gradually increased from the first to the fourth quartile groups of baseline HGI. The odds ratio (OR) for incident CAC was the highest among the four groups divided by the quartiles of the baseline HGI and was significant after adjustment for confounding variables (vs first quartile group: OR, 1.632; 95% confidence interval, 1.024 to 2.601). The incidence of and risk for CAC development were significantly higher than in other groups compared with the low-to-low group after adjustment for confounding factors; however, when baseline HbA1c level was included in the model, only participants with a low-to-high HGI over 4 years showed a significantly increased OR for CAC development compared with the low-to-low group (OR, 1.722; 95% confidence interval, 1.046 to 2.833). The participants with a high baseline HGI and consistently high HGI showed a higher risk for incident CAC than those with a low baseline HGI. An increased HGI over 4 years significantly increased the risk for CAC regardless of the baseline HbA1c levels. Copyright © 2017 Endocrine Society

  3. Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication

    Directory of Open Access Journals (Sweden)

    Ahuva Weltman

    2016-10-01

    Full Text Available The acquisition of high-fidelity, long-term neural recordings in vivo is critically important to advance neuroscience and brain–machine interfaces. For decades, rigid materials such as metal microwires and micromachined silicon shanks were used as invasive electrophysiological interfaces to neurons, providing either single or multiple electrode recording sites. Extensive research has revealed that such rigid interfaces suffer from gradual recording quality degradation, in part stemming from tissue damage and the ensuing immune response arising from mechanical mismatch between the probe and brain. The development of “soft” neural probes constructed from polymer shanks has been enabled by advancements in microfabrication; this alternative has the potential to mitigate mismatch-related side effects and thus improve the quality of recordings. This review examines soft neural probe materials and their associated microfabrication techniques, the resulting soft neural probes, and their implementation including custom implantation and electrical packaging strategies. The use of soft materials necessitates careful consideration of surgical placement, often requiring the use of additional surgical shuttles or biodegradable coatings that impart temporary stiffness. Investigation of surgical implantation mechanics and histological evidence to support the use of soft probes will be presented. The review concludes with a critical discussion of the remaining technical challenges and future outlook.

  4. A Characterization of 2-Tree Probe Interval Graphs

    Directory of Open Access Journals (Sweden)

    Brown David E.

    2014-08-01

    Full Text Available A graph is a probe interval graph if its vertices correspond to some set of intervals of the real line and can be partitioned into sets P and N so that vertices are adjacent if and only if their corresponding intervals intersect and at least one belongs to P. We characterize the 2-trees which are probe interval graphs and extend a list of forbidden induced subgraphs for such graphs created by Pržulj and Corneil in [2-tree probe interval graphs have a large obstruction set, Discrete Appl. Math. 150 (2005 216-231

  5. HgI2 detector fabrication

    International Nuclear Information System (INIS)

    Gonzalez, M.; Perez, J. M.

    1996-01-01

    The aim of the present work is to describe the steps followed to fabricate an ionizing radiation detector based on synthetic mercuric iodide monocrystal layers. Firstly, the crystalline orientation method has been describe, which is needed before the layer cutting perpendicularly to the (001) crystallographic. It is also defined the proceeding to crystal face finishing by a mechanical polishing and subsequent chemical etching. then, the metal electrode deposition and the view connection has been explained. Finally, the technique followed to encapsulate the detector with a polymeric thin film deposition has been described. (Author) 10 refs

  6. HgI2 detector fabrication

    International Nuclear Information System (INIS)

    Gonzalez, M.; Perez, J.M.

    1996-01-01

    The aim of the present work is to describe the steps followed to fabricate an ionizing radiation detector based on synthetic mercuric iodide monocrystal layers. Firstly, the crystalline orientation method has been describe, which is needed before the layer cutting perpendicullarly to the (001) crystallographyc. It is also defined the proceeding to crystal face finishing by a mechanical polishing and subsequent chemical etching. Then, the metal electrode deposition and the wire connection has been explained. Finally, the technique followed to encapsulate the detector with a polimeric thin film deposition has been described

  7. Efeitos de materiais orgânicos e da umidade do solo na patogenicidade de Rhizoctonia solani Kühn GA-4 HGI ao feijoeiro The role of the organic material amended and the soil moisture on the pathogenicity of Rhizoctonia solani Kühn AG-4 HGI in snap bean

    Directory of Open Access Journals (Sweden)

    Roseli Chela Fenille

    1999-10-01

    Full Text Available Foram avaliados, em casa de vegetação, os efeitos das seguintes variáveis sobre a patogenicidade de Rhizoctonia solani GA-4 HGI a plantas de feijão (Phaseolus vulgaris L., em solo artificialmente infestado: presença de materiais orgânicos com diferentes relações C:N (torta de mamona e bagaço de cana; níveis de decomposição da matéria orgânica, e condições de umidade do solo incorporado. A umidade do solo até o momento da semeadura foi mantida sob duas condições: 20% ou acima de 80% da capacidade de campo. Foram realizadas semeaduras aos 0, 7, 14, 21, 28 e 35 dias após inoculação e incorporação. As avaliações foram realizadas 14 dias após cada semeadura. O material com baixa relação C:N propiciou o aumento da incidência de R. solani no feijoeiro, enquanto o material com alta relação C:N não interferiu na incidência do patógeno. A incidência de R. solani no feijoeiro, em solo incorporado, foi independente da condição de umidade.The pathogenicity of Rhizoctonia solani AG-4 HGI on bean (Phaseolus vulgaris L. plants was evaluated, in artificially infested soil under greenhouse conditions, when submitted to the following treatments: amendments with different C:N ratios (castor-oil cake and sugar-cane bagasse; different organic matter decomposition levels; different moisture contents of the amended soil. Until the moment of sowing the soil moisture was maintained at 20% of the moisture-holding capacity or above 80%. The sowings were made at 0, 7, 14, 21, 28 and 35 days after the inoculation and amendments incorporation. Evaluations were carried out 14 days after each sowing date. The amendment with low C:N ratio increased the incidence of R. solani on bean plants, in any decomposition level, whereas the amendment with high C:N ratio did not interfere on the incidence of the pathogen. The incidence of R. solani on bean plants, in a soil amended with both castor-oil cake or sugar-cane bagasse, was independent of the

  8. Statistical decision making with a dual-detector probe

    International Nuclear Information System (INIS)

    Hickernell, T.S.

    1988-01-01

    Conventional imaging techniques for cancer detection have difficulty finding small, deep tumors. Single-detector radiation probes have been developed to search for deep lesions in a patient who has been given a tumor-seeking radiopharmaceutical. These probes perform poorly, however, when the background activity in the patient varies greatly from site to site. We have developed a surgical dual-detector probe that solves the problem of background activity variation, by simultaneously monitoring counts from a region of interest and counts from adjacent normal tissue. A comparison of counts from the detectors can reveal the class of tissue, tumor or normal, in the region of interest. In this study, we apply methods from statistical decision theory and derive a suitable comparison of counts to help us decide whether a tumor is present in the region of interest. We use the Hotelling trace criterion with a few assumptions to find a linear discriminant function, which can be reduced to a normalized subtraction of the counts for large background count-rate variations. Using a spatial response map of the dual probe, a computer torso phantom, and estimates of activity distribution, we simulate a surgical staging procedure to test the dual probe and the discriminant functions

  9. Fast reciprocating probe system on the HL-2A tokamak

    International Nuclear Information System (INIS)

    Yan Longwen; Hong Wenyu; Qian Jun; Luo Cuiwen; Pan Li

    2005-01-01

    A reciprocating probe system has been installed at the midplane of the HL-2A tokamak. The probe is used to measure plasma edge density, temperature, floating potential, and corresponding fluctuation profiles with 8 cm scan from the scrape-off layer to the plasma boundary. The reciprocating probe can move at a speed of 1 m/s. A digital grating displacement measurement system that can provide a high displacement resolution of 0.04 mm is applied to the reciprocating probe system for the first time. A port located behind the vacuum isolation valve is designed for viewing and the exchange of the probe head. Different probe heads can be used to satisfy different experimental requirements. The first probe head had four graphite measurement tips. For high frequency response, no isolation amplifier is used in the electric circuit of the probe measurement. A personal computer via an analog-to-digital digitizer card acquires probe system data, which are sent to a data server by optical fiber after a discharge. All data are sent to the centralized data management system of the HL-2A. In this article we presented the edge temperature and density profiles for the limiter and divertor configurations of a selected plasma discharge

  10. A Dansyl-Rhodamine Based Fluorescent Probe for Detection of Hg2+ and Cu2.

    Science.gov (United States)

    Yuan, Shizhuang; Su, Wei; Wang, Enju

    2017-09-01

    A novel fluorescent probe based on dansyl-appended rhodamine B was developed. The probe can selectively recognize and sense Hg2+ and Cu2+ from other common metal ions by showing unique fluorescence and absorption characteristics. In MeCN/HEPES buffer solution, the probe gives a ratiometric fluorescent response to Hg2+, which was ascribed to the fluorescence resonance energy transfer from dansyl moiety to the ring-opened rhodamine B moiety, while the presence of Cu2+ causes fluorescence quenching. Beside the fluorescence change, the presence of Cu2+ and Hg2+ can induce intensive absorption at about 555 nm, which resulted in a color change from colorless to pink.

  11. Probing SH2-domains using Inhibitor Affinity Purification (IAP).

    Science.gov (United States)

    Höfener, Michael; Heinzlmeir, Stephanie; Kuster, Bernhard; Sewald, Norbert

    2014-01-01

    Many human diseases are correlated with the dysregulation of signal transduction processes. One of the most important protein interaction domains in the context of signal transduction is the Src homology 2 (SH2) domain that binds phosphotyrosine residues. Hence, appropriate methods for the investigation of SH2 proteins are indispensable in diagnostics and medicinal chemistry. Therefore, an affinity resin for the enrichment of all SH2 proteins in one experiment would be desirable. However, current methods are unable to address all SH2 proteins simultaneously with a single compound or a small array of compounds. In order to overcome these limitations for the investigation of this particular protein family in future experiments, a dipeptide-derived probe has been designed, synthesized and evaluated. This probe successfully enriched 22 SH2 proteins from mixed cell lysates which contained 50 SH2 proteins. Further characterization of the SH2 binding properties of the probe using depletion and competition experiments indicated its ability to enrich complexes consisting of SH2 domain bearing regulatory PI3K subunits and catalytic phosphoinositide 3-kinase (PI3K) subunits that have no SH2 domain. The results make this probe a promising starting point for the development of a mixed affinity resin with complete SH2 protein coverage. Moreover, the additional findings render it a valuable tool for the evaluation of PI3K complex interrupting inhibitors.

  12. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, M.; Yasunaga, T.; Konishi, K. [Kyushu University, Department of Advanced Medical Initiatives, Faculty of Medical Sciences, Fukuoka (Japan); Tanoue, K.; Ieiri, S. [Kyushu University Hospital, Department of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Kishi, K. [Hitachi Ltd, Mechanical Engineering Research Laboratory, Hitachinaka-Shi, Ibaraki (Japan); Nakamoto, H. [Hitachi Medical Corporation, Application Development Office, Kashiwa-Shi, Chiba (Japan); Ikeda, D. [Mizuho Ikakogyo Co. Ltd, Tokyo (Japan); Sakuma, I. [The University of Tokyo, Graduate School of Engineering, Bunkyo-Ku, Tokyo (Japan); Fujie, M. [Waseda University, Graduate School of Science and Engineering, Shinjuku-Ku, Tokyo (Japan); Dohi, T. [The University of Tokyo, Graduate School of Information Science and Technology, Bunkyo-Ku, Tokyo (Japan)

    2008-04-15

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  13. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    International Nuclear Information System (INIS)

    Hashizume, M.; Yasunaga, T.; Konishi, K.; Tanoue, K.; Ieiri, S.; Kishi, K.; Nakamoto, H.; Ikeda, D.; Sakuma, I.; Fujie, M.; Dohi, T.

    2008-01-01

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  14. Secondary and Tertiary Hyperparathyroidism, State of the Art Surgical Management

    Science.gov (United States)

    Pitt, Susan C.; Sippel, Rebecca S.

    2010-01-01

    Synopsis This article reviews the current surgical management of patients with secondary and tertiary hyperparathyroidism. The focus is on innovative surgical strategies that have improved the care of these patients over the past 10 to 15 years. Modalities such as intraoperative parathyroid hormone monitoring and radioguided probe utilization are discussed. PMID:19836494

  15. Effects of Changing the Amount and Source of Dietary Carbohydrates on Symptoms and Dietary Satisfaction Over a 1-Year Period in Subjects with Type 2 Diabetes: Canadian Trial of Carbohydrates in Diabetes (CCD).

    Science.gov (United States)

    Wolever, Thomas M S; Chiasson, Jean-Louis; Josse, Robert G; Leiter, Lawrence A; Maheux, Pierre; Rabasa-Lhoret, Rémi; Rodger, N Wilson; Ryan, Edmond A

    2017-04-01

    To determine the long-term effects of changing the amount or source of dietary carbohydrate on quality of life (QOL), symptoms and dietary satisfaction in people with type 2 diabetes. Subjects with diabetes treated by diet alone (n=162) were randomly assigned to high-carbohydrate/high-glycemic-index (HGI) diets; high-carbohydrate/low-glycemic-index (LGI) diets; or lower-carbohydrate/high-monounsaturated-fat (LC) diets for 1 year. We measured QOL at baseline and at study's end, and we measured symptoms and dietary satisfaction quarterly. The HGI, LGI and LC diets contained, respectively, 47±1, 52±1 and 40±1% energy carbohydrate; 30±1, 27±1 and 40±1% fat with GI 64±0.4, 55±0.4 and 59±0.4. Significantly more participants reported increased flatulence on LGI than on LC and HGI diets at 3 months (41%, 19%, 14%; pvs. 14%, 19%; pvs. 22%, 23%; pcarbohydrate diet than on the 50% carbohydrate diet, the LGI diet was no less satisfying than the HGI diet. Changes in appetite and dietary satisfaction may influence body weight and glycemic control, or vice-versa. Copyright © 2016 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  16. Effect of non-surgical periodontal therapy on C-reactive protein, oxidative stress, and matrix metalloproteinase (MMP)-9 and MMP-2 levels in patients with type 2 diabetes: a randomized controlled study.

    Science.gov (United States)

    Koromantzos, Panagiotis A; Makrilakis, Konstantinos; Dereka, Xanthippi; Offenbacher, Steven; Katsilambros, Nicholas; Vrotsos, Ioannis A; Madianos, Phoebus N

    2012-01-01

    It is well accepted that glycemic control in patients with diabetes mellitus (DM) is affected by systemic inflammation and oxidative stress. The effect of periodontal therapy on these systemic factors may be related to improvement on glycemic status. The aim of the present study is to assess over a period of 6 months the effect of non-surgical periodontal therapy on serum levels of high-sensitivity C-reactive protein (hsCRP), d-8-iso prostaglandin F2a (d-8-iso) as a marker of oxidative stress, and matrix metalloproteinase (MMP)-2 and MMP-9 on patients with type 2 DM. Sixty participants with type 2 DM and moderate to severe periodontal disease were randomized into intervention (IG) and control (CG) groups. IG received scaling and root planing, whereas CG received supragingival cleaning at baseline and scaling and root planing at 6 months. Participants of both groups were evaluated at baseline and 1, 3, and 6 months. Periodontal data recorded at each visit included probing depth, clinical attachment loss, bleeding on probing, and gingival index. Blood was collected at each visit for the assay of serum glycated hemoglobin A1c (A1c), hsCRP, d-8-iso, MMP-2, and MMP-9. Although there was a trend to a reduction in hsCRP, d-8-iso and MMP-9 it did not reach statistical significance. MMP-2 levels remained unchanged after periodontal treatment. Effective non-surgical periodontal treatment of participants with type 2 DM and moderate to severe periodontal disease improved significantly A1c levels but did not result in a statistically significant improvement in hsCRP, d-8-iso, MMP-2, and MMP-9 levels.

  17. Efficacy of hypnosis/guided imagery in fibromyalgia syndrome - a systematic review and meta-analysis of controlled trials

    Science.gov (United States)

    2011-01-01

    Background Recent systematic reviews on psychological therapies of fibromyalgia syndrome (FMS) did not consider hypnosis/guided imagery (H/GI). Therefore we performed a systematic review with meta-analysis of the efficacy of H/GI in FMS. Methods We screened http://ClinicalTrials.gov, Cochrane Library, MEDLINE, PsycINFO and SCOPUS (through December 2010). (Quasi-) randomized controlled trials (CTs) comparing H/GI with controls were analyzed. Outcomes were pain, sleep, fatigue, depressed mood and health-related quality of life (HRQOL). Effects were summarized using standardized mean differences (SMD). Results Six CTs with 239 subjects with a median of 9 (range 7-12) H/GI-sessions were analysed. The median number of patients in the H/GI groups was 20 (range 8-26). Three studies performed follow-ups. H/GI reduced pain compared to controls at final treatment (SMD -1.17 [95% CI -2.21, -0.13]; p = 0.03). H/GI did not reduce limitations of HRQOL at final treatment (SMD -0.90 [95% CI -2.55, 0.76]; p = 0.29) compared to controls. Effect sizes on fatigue, sleep and depressed mood at final treatment and follow-up and on pain and HRQOL at follow-up were not calculated because of limited data available. The significant effect on pain at final treatment was associated with low methodological and low treatment quality. Conclusion Further studies with better treatment quality and adequate methodological quality assessing all key domains of FMS are necessary to clarify the efficacy of H/GI in FMS. PMID:21676255

  18. Satisfactory surgical outcome of T2 gastric cancer after modified D2 lymphadenectomy.

    Science.gov (United States)

    Zhang, Shupeng; Wu, Liangliang; Wang, Xiaona; Ding, Xuewei; Liang, Han

    2017-04-01

    Though D2 lymphadenectomy has been increasingly regarded as standard surgical procedure for advanced gastric cancer (GC), the modified D2 (D1 + 7, 8a and 9) lymphadenectomy may be more suitable than D2 dissection for T2 stage GC. The purpose of this study is to elucidate whether the surgical outcome of modified D2 lymphadenectomy was comparable to that of standard D2 dissection in T2 stage GC patients. A retrospective cohort study with 77 cases and 77 controls matched for baseline characteristics was conducted. Patients were categorized into two groups according to the extent of lymphadenectomy: the modified D2 group (mD2) and the standard D2 group (D2). Surgical outcome and recurrence date were compared between the two groups. The 5-year overall survival (OS) rate was 71.4% for patients accepted mD2 lymphadenectomy and 70.1% for those accepted standard D2, respectively, and the difference was not statistically significant. Multivariate survival analysis revealed that curability, tumor size, TNM stage and postoperative complications were independently prognostic factors for T2 stage GC patients. Patients in the mD2 group tended to have less intraoperative blood loss (P=0.001) and shorter operation time (P<0.001) than those in the D2 group. While there were no significant differences in recurrence rate and types, especially lymph node recurrence, between the two groups. The surgical outcome of mD2 lymphadenectomy was equal to that of standard D2, and the use of mD2 instead of standard D2 can be a better option for T2 stage GC.

  19. Surgical Regenerative Treatments for Peri-Implantitis: Meta-analysis of Recent Findings in a Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Povilas Daugela

    2016-09-01

    Full Text Available Objectives: The purpose of the present study was to systematically review the literature on the surgical regenerative treatment of the peri-implantitis and to determine an effective therapeutic predictable option for their clinical management. Material and Methods: The study searched MEDLINE and EMBASE databases from 2006 to 2016. Clinical human studies that had reported changes in probing depth (PD and/or bleeding on probing (BOP and/or radiologic marginal bone level (RBL changes after peri-implantitis surgical treatment at 12-month follow-up or longer were included accordingly to PRISMA guidelines. Results: The initial search obtained 883 citations. After screening and determination of eligibility, 18 articles were included in the review. The meta-analysis of selected studies revealed that the weighted mean RBL fill was 1.97 mm (95% confidence interval [CI] = 1.58 to 2.35 mm, PD reduction was 2.78 mm (95% CI = 2.31 to 3.25 mm, and BOP reduced by 52.5% (95% CI = 41.6 to 63.1%. Defect fill in studies using and not using barrier membranes for graft coverage was 1.86 mm (95% CI = 1.36 to 2.36 mm and 2.12 mm (95% CI = 1.46 to 2.78 mm correspondingly. High heterogeneity among the studies regarding defects morphology, surgical protocols, and selection of biomaterials were found. Conclusions: All included studies underlined an improvement of clinical conditions after the surgical regenerative treatment of peri-implantitis, however, there is a lack of scientific evidence in the literature regarding the superiority of the regenerative versus non-regenerative surgical treatment. The presence of a barrier membrane or submergence in the regenerative procedure does not seem to be fundamental in order to obtain clinical success of the surgery.

  20. Intracellular O2 sensing probe based on cell-penetrating phosphorescent nanoparticles.

    Science.gov (United States)

    Fercher, Andreas; Borisov, Sergey M; Zhdanov, Alexander V; Klimant, Ingo; Papkovsky, Dmitri B

    2011-07-26

    A new intracellular O(2) (icO(2)) sensing probe is presented, which comprises a nanoparticle (NP) formulation of a cationic polymer Eudragit RL-100 and a hydrophobic phosphorescent dye Pt(II)-tetrakis(pentafluorophenyl)porphyrin (PtPFPP). Using the time-resolved fluorescence (TR-F) plate reader set-up, cell loading was investigated in detail, particularly the effects of probe concentration, loading time, serum content in the medium, cell type, density, etc. The use of a fluorescent analogue of the probe in conjunction with confocal microscopy and flow cytometry analysis, revealed that cellular uptake of the NPs is driven by nonspecific energy-dependent endocytosis and that the probe localizes inside the cell close to the nucleus. Probe calibration in biological environment was performed, which allowed conversion of measured phosphorescence lifetime signals into icO(2) concentration (μM). Its analytical performance in icO(2) sensing experiments was demonstrated by monitoring metabolic responses of mouse embryonic fibroblast cells under ambient and hypoxic macroenvironment. The NP probe was seen to generate stable and reproducible signals in different types of mammalian cells and robust responses to their metabolic stimulation, thus allowing accurate quantitative analysis. High brightness and photostability allow its use in screening experiments with cell populations on a commercial TR-F reader, and for single cell analysis on a fluorescent microscope.

  1. A benzothiazole-based fluorescent probe for distinguishing and bioimaging of Hg{sup 2+} and Cu{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Biao; Huang, Liyan; Su, Wei; Duan, Xiaoli; Li, Haitao, E-mail: haitao-li@hunnu.edu.cn; Yao, Shouzhuo

    2017-02-15

    A new benzothiazole-based fluorescent probe 2-(benzo[d]thiazol-2-yl)-4-(1,3- dithian-2-yl)phenol (BT) with two different reaction sites, a thioacetal group (site 1 for Hg{sup 2+}), and O and N atoms of the benzothiazole dye (site 2 for Cu{sup 2+}), was designed and synthesized. The probe BT showed ratiometric fluorescent response to Hg{sup 2+} and fluorescence quenching behavior to Cu{sup 2+}, which induces naked-eye fluorescent color changes from green to blue and colorless, respectively. Moreover, it displayed highly sensitivity and selectivity toward Hg{sup 2+} and Cu{sup 2+} without interference from other metal ions. The sensing mechanisms were also confirmed by {sup 1}H NMR titration, mass spectrum and Job's plot analyses. Finally, probe BT was successfully used for fluorescent imaging of Hg{sup 2+} and Cu{sup 2+} in living cells, demonstrating its potential applications in biological science. - Highlights: • A benzothiazole-based probe for multiple metal ions has been firstly developed. • The differential sensing mechanisms of Hg{sup 2+} and Cu{sup 2+} relied on different reaction. • The probe could be used to monitor Hg{sup 2+} and Cu{sup 2+}in vitro and in vivo with distinct fluorescence changes.

  2. Development of High-Resolution Scintillator Systems

    International Nuclear Information System (INIS)

    Larry A. Franks; Warnick J. Kernan

    2007-01-01

    Mercuric iodide (HgI2) is a well known material for the direct detection of gamma-rays; however, the largest volume achievable is limited by the thickness of the detector which needs to be a small fraction of the average trapping length for electrons. We report results of using HgI2 crystals to fabricate photocells used in the readout of scintillators. The optical spectral response and efficiency of these photocells were measured and will be reported. Nuclear response from an HgI2 photocell that was optically matched to a cerium-activated scintillator is presented and discussed. Further improvements can be expected by optimizing the transparent contact technology

  3. RELATIONSHIPS BETWEEN INITIAL PROBING DEPTH AND CHANGES IN THE CLINICAL PARAMETERS FOLLOWING NON-SURGICAL PERIODONTAL TREATMENT IN CHRONIC PERIODONTITIS

    Directory of Open Access Journals (Sweden)

    Süleyman Emre MESELİ

    2017-10-01

    Full Text Available Purpose: The aim of this study was to evaluate the relationship between initial probing depth (IPD and changes in clinical parameters following non-surgical periodontal treatment (NPT in chronic periodontitis patients. Subjects and Methods: A total of 1672 periodontal pockets having 3mm≤IPD≤9mm of depth in 15 chronic periodontitis patients were included. NPT consisting of oral hygiene instructions, scaling and root planing was applied in two sessions. Probing depth (PD, clinical attachment level, gingival recessions (GR were measured before and eight weeks after treatment. Pocket sites were grouped according to their IPD and root number as single- or multi-rooted teeth. Results: Other than the sites having 3 mm IPD, PD reduction and GR increase were significant in all groups (p<0.001. Attachment gains (AG were significant in all single-rooted teeth (p<0.001 again except those having IPD=3mm. However, AG was significant in multi-rooted teeth having only 7mm≤IPD≤9mm (p<0.05. Positive correlations were observed between IPD and PD reduction, GR increase and AG in single-rooted teeth (p<0.001. Furthermore, positive correlations were found between IPD and PD reduction and GR increase in multi-rooted teeth (p<0.001, but there was no correlation between IPD and AG. Conclusion: NPT may lead to positive association between IPD and PD reduction as well as GR increase, which is independent from tooth root anatomy.

  4. A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy.

    Science.gov (United States)

    Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2012-10-08

    We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope's instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications.

  5. A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy

    Science.gov (United States)

    Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2012-01-01

    We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope’s instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications. PMID:23188360

  6. M Abdul Khadar

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. M Abdul Khadar. Articles written in Bulletin of Materials Science. Volume 23 Issue 5 October 2000 pp 361-367 Nanomaterials. Dielectric properties of nanophase Ag2HgI4 and Ag2HgI4–Al2O3 nanocomposites · S Sankara Narayanan Potty M Abdul Khadar · More Details ...

  7. A fast-response two-photon fluorescent probe for imaging endogenous H2O2 in living cells and tissues

    Science.gov (United States)

    Lu, Yanan; Shi, Xiaomin; Fan, Wenlong; Black, Cory A.; Lu, Zhengliang; Fan, Chunhua

    2018-02-01

    As a second messenger, hydrogen peroxide plays significant roles in numerous physiological and pathological processes and is related to various diseases including inflammatory disease, diabetes, neurodegenerative disorders, cardiovascular disease and Alzheimer's disease. Two-photon (TP) fluorescent probes reported for the detection of endogenous H2O2 are rare and most have drawbacks such as slow response and low sensitivity. In this report, we demonstrate a simple H2O2-specific TP fluorescent probe (TX-HP) containing a two-photon dye 6-hydroxy-2,3,4,4a-tetrahydro-1H-xanthen-1-one (TX) on the modulation of the ICT process. The probe exhibits a rapid fluorescent response to H2O2 in 9 min with both high sensitivity and selectivity. The probe can detect exogenous H2O2 in living cells. Furthermore, the probe is successfully utilized for imaging H2O2 in liver tissues.

  8. 2-Aminopurine hairpin probes for the detection of ultraviolet-induced DNA damage

    International Nuclear Information System (INIS)

    El-Yazbi, Amira F.; Loppnow, Glen R.

    2012-01-01

    Highlights: ► Molecular beacon with 2AP bases detects DNA damage in a simple mix-and-read assay. ► Molecular beacons with 2AP bases detect damage at a 17.2 nM limit of detection. ► The 2AP molecular beacon is linear over a 0–3.5 μM concentration range for damage. - Abstract: Nucleic acid exposure to radiation and chemical insults leads to damage and disease. Thus, detection and understanding DNA damage is important for elucidating molecular mechanisms of disease. However, current methods of DNA damage detection are either time-consuming, destroy the sample, or are too specific to be used for generic detection of damage. In this paper, we develop a fluorescence sensor of 2-aminopurine (2AP), a fluorescent analogue of adenine, incorporated in the loop of a hairpin probe for the quantification of ultraviolet (UV) C-induced nucleic acid damage. Our results show that the selectivity of the 2AP hairpin probe to UV-induced nucleic acid damage is comparable to molecular beacon (MB) probes of DNA damage. The calibration curve for the 2AP hairpin probe shows good linearity (R 2 = 0.98) with a limit of detection of 17.2 nM. This probe is a simple, fast and economic fluorescence sensor for the quantification of UV-induced damage in DNA.

  9. A combined tactile and Raman probe for tissue characterization—design considerations

    International Nuclear Information System (INIS)

    Nyberg, Morgan; Candefjord, Stefan; Ramser, Kerstin; Lindahl, Olof A; Jalkanen, Ville

    2012-01-01

    Histopathology is the golden standard for cancer diagnosis and involves the characterization of tissue components. It is labour intensive and time consuming. We have earlier proposed a combined fibre-optic near-infrared Raman spectroscopy (NIR-RS) and tactile resonance method (TRM) probe for detecting positive surgical margins as a complement to interoperative histopathology. The aims of this study were to investigate the effects of attaching an RS probe inside a cylindrical TRM sensor and to investigate how laser-induced heating of the fibre-optic NIR-RS affected the temperature of the RS probe tip and an encasing TRM sensor. In addition, the possibility to perform fibre-optic NIR-RS in a well-lit environment was investigated. A small amount of rubber latex was preferable for attaching the thin RS probe inside the TRM sensor. The temperature rise of the TRM sensor due to a fibre-optic NIR-RS at 270 mW during 20 s was less than 2 °C. Fibre-optic NIR-RS was feasible in a dimmed bright environment using a small light shield and automatic subtraction of a pre-recorded contaminant spectrum. The results are promising for a combined probe for tissue characterization. (paper)

  10. TiO2 Nanoparticles as a Soft X-ray Molecular Probe

    Energy Technology Data Exchange (ETDEWEB)

    Larabell, Carolyn; Ashcroft, Jared M.; Gu, Weiwei; Zhang, Tierui; Hughes, Steven M.; Hartman, Keith B.; Hofmann, Cristina; Kanaras, Antonios G.; Kilcoyne, David A.; Le Gros, Mark; Yin, Yadong; Alivisatos, A. Paul; Larabell, Carolyn A.

    2007-06-30

    With the emergence of soft x-ray techniques for imaging cells, there is a pressing need to develop protein localization probes that can be unambiguously identified within the region of x-ray spectrum used for imaging. TiO2 nanocrystal colloids, which have a strong absorption cross-section within the "water-window" region of x-rays, areideally suited as soft x-ray microscopy probes. To demonstrate their efficacy, TiO2-streptavidin nanoconjugates were prepared and subsequently labeled microtubules polymerized from biotinylated tubulin. The microtubules were imaged using scanning transmission x-ray microscopy (STXM), and the TiO2 nanoparticle tags were specifically identified using x-ray absorption near edge spectroscopy (XANES). These experiments demonstrate that TiO2 nanoparticles are potential probes for protein localization analyses using soft x-ray microscopy.

  11. Highly selective detection of glutathione using a NIP/Cu2+ complex fluorescent probe

    International Nuclear Information System (INIS)

    Liang Wenrui; Zhao Zhi; Zhang Yang; Wang Qiusheng; Zhao Xin; Ouyang Jie

    2012-01-01

    A novel fluorescent compound, 4-(trimethyl ammonium chloride)acetamide-2-(1H-naphtho[2,3-d]imidazol-2-yl)phenol (TMACA-NIP), was synthesized and used as a fluorescent probe for detecting glutathione reduced (GSH). The new NIP-based probe exhibited high fluorescence in water, which was quenched during the presence of copper (II) due to the complexation between TMACA-NIP and Cu 2+ . But after adding GSH into the TMACA-NIP and Cu 2+ system, the fluorescence of TMACA-NIP was recovered because the binding force between GSH and Cu 2+ is stronger than that between TMACA-NIP and Cu 2+ , which destroys the equilibrium between NIP and copper (II) ions and releases the fluorescence probe of TMACA-NIP. This three-component competing system of NIP/Cu 2+ /GSH can be used to detect GSH simply and rapidly. - Highlights: ► A novel fluorescence probe was developed to detect GSH that operates in aqueous solution. ► TMACA-NIP was synthesized and employed as “read-out” units of NIP/Cu 2+ /GSH. ► NIP-based probe shows high selectivity over other sulfhydryl compounds.

  12. Surgical Treatment of Severe Traumatic Brain Injury in Switzerland: Results from a Multicenter Study.

    Science.gov (United States)

    Rossi-Mossuti, Frédéric; Fisch, Urs; Schoettker, Patrick; Gugliotta, Marinella; Morard, Marc; Schucht, Philippe; Schatlo, Bawarjan; Levivier, Marc; Walder, Bernhard; Fandino, Javier

    2016-01-01

    Since the introduction of modern surgical techniques and monitoring tools for the treatment of severe traumatic brain injury (TBI) in Switzerland, standardized nationwide operative procedures are still lacking. This study aimed to assess surgical management and monitoring strategies in patients admitted throughout Switzerland with severe TBI. Demographic, clinical, and radiologic data from a prospective national cohort study on severe brain-injured patients (Patient-relevant Endpoints after Brain Injury from Traumatic Accidents [PEBITA]) were collected during a 3-year period. This study evaluated patients admitted to 7 of the 11 trauma centers included in PEBITA. We retrospectively analyzed surgery-related computed tomography (CT) findings prior to and after treatment, intracranial pressure (ICP) monitoring, size and technical features of craniotomy, as well as surgical complications. ResULTS: This study included 353 of the 921 patients enrolled in PEBITA who underwent surgical treatment for severe TBI. At admission, acute subdural hematoma was the most frequent focal lesion diagnosed (n = 154 [44%]), followed by epidural hematoma (n = 96 [27%]) and intracerebral hematoma (n = 84 [24%]). A total of 198 patients (61%) presented with midline shift. Clinical deterioration in terms of Glasgow Coma Scale scores or intractable ICP values as an indication for surgical evacuation or decompression were documented in 20% and 6%, respectively. A total of 97 (27.5%) only received a catheter/probe for ICP monitoring. Surgical procedures to treat a focal lesion or decompress the cerebrum were performed in 256 patients (72.5%). Of the 290 surgical procedures (excluding ICP probe implantation), craniotomy (137 [47.2%]) or decompressive craniectomy (133 [45.9%]) were performed most frequently. The mean size of craniectomy in terms of maximal linear width on the CT axial slice was 8.4 ± 2.9 cm. Intraoperative ICP monitoring was reported in 61% of the interventions. Significant

  13. Two-year clinical outcomes following non-surgical mechanical therapy of peri-implantitis with adjunctive diode laser application.

    Science.gov (United States)

    Mettraux, Gérald R; Sculean, Anton; Bürgin, Walter B; Salvi, Giovanni E

    2016-07-01

    Non-surgical mechanical therapy of peri-implantitis (PI) with/without adjunctive measures yields limited clinical improvements. To evaluate the clinical outcomes following non-surgical mechanical therapy of PI with adjunctive application of a diode laser after an observation period ≥2 years. At baseline (BL), 15 patients with 23 implants with a sandblasted and acid-etched (SLA) surface diagnosed with PI were enrolled and treated. PI was defined as presence of probing pocket depths (PPD) ≥5 mm with bleeding on probing (BoP) and/or suppuration and ≥2 threads with bone loss after delivery of the restoration. Implant sites were treated with carbon fiber and metal curettes followed by repeated application of a diode laser 3x for 30 s (settings: 810 nm, 2.5 W, 50 Hz, 10 ms). This procedure was performed at Day 0 (i.e., baseline), 7 and 14. Adjunctive antiseptics or adjunctive systemic antibiotics were not prescribed. All implants were in function after 2 years. The deepest PPD decreased from 7.5 ± 2.6 mm to 3.6 ± 0.7 mm at buccal (P surgical mechanical therapy of PI with adjunctive repeated application of a diode laser yielded significant clinical improvements after an observation period of at least 2 years. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. A lysosome-locating and acidic pH-activatable fluorescent probe for visualizing endogenous H2O2 in lysosomes.

    Science.gov (United States)

    Liu, Jun; Zhou, Shunqing; Ren, Jing; Wu, Chuanliu; Zhao, Yibing

    2017-11-20

    There is increasing evidence indicating that lysosomal H 2 O 2 is closely related to autophagy and apoptotic pathways under both physiological and pathological conditions. Therefore, fluorescent probes that can be exploited to visualize H 2 O 2 in lysosomes are potential tools for exploring diverse roles of H 2 O 2 in cells. However, functional exploration of lysosomal H 2 O 2 is limited by the lack of fluorescent probes capable of compatibly sensing H 2 O 2 under weak acidic conditions (pH = 4.5) of lysosomes. Lower spatial resolution of the fluorescent visualization of lysosomal H 2 O 2 might be caused by the interference of signals from cytosolic and mitochondrial H 2 O 2 , as well as the non-specific distribution of the probes in cells. In this work, we developed a lysosome-locating and acidic-pH-activatable fluorescent probe for the detection and visualization of H 2 O 2 in lysosomes, which consists of a H 2 O 2 -responsive boronate unit, a lysosome-locating morpholine group, and a pH-activatable benzorhodol fluorophore. The response of the fluorescent probe to H 2 O 2 is significantly more pronounced under acidic pH conditions than that under neutral pH conditions. Notably, the present probe enables the fluorescence sensing of endogenous lysosomal H 2 O 2 in living cells without external stimulations, with signal interference from the cytoplasm and other intracellular organelles being negligible.

  15. Nanomaterials and MRI molecular probe

    International Nuclear Information System (INIS)

    Inubushi, Toshiro

    2008-01-01

    This paper presents the current state and future prospect of enhancing probes in MRI which enable to image specific cells and molecules mainly from the aspect of cell trafficking. Although MRI requires such probes for specific imaging, it has an advantage that anatomical images are simultaneously available even during surgical operation without radiation exposure, differing from X-CT, -transillumination and positron emission tomography (PET). In the development of novel MRI molecular probes, the recent topic concerns the cell trafficking biology where cells related with transplantation and immunological therapy can be traced. Although superparamagnetic iron oxide (SPIO) has been used as a commercially available enhancer, this nanoparticle has problems like a difficulty to penetrate cell, cytotoxicity and others. For these, authors have developed the nanoparticle SPIO covered with silica shell, which can be chemically modified, e.g., by binding fluorescent pigments to possibly allow MR bimodal molecular imaging. For penetration of particles in cells, envelop of Sendai virus is used. PET-CT has been more popular these days; however, MRI is superior to CT for imaging soft tissues, and development of PET-MRI is actively under progress aiming the multi-modal imaging. At present, molecular probes for MRI are certainly not so many as those for PET and cooperative efforts to develop the probes are required in medical, technological and pharmaceutical fields. (R.T.)

  16. Diiodido[methyl 2-(quinolin-8-yloxyacetate-κN]mercury(II

    Directory of Open Access Journals (Sweden)

    Yu-Hong Wang

    2012-08-01

    Full Text Available In the title mononuclear complex, [HgI2(C12H11NO3], the HgII ion has a distorted trigonal–planar coordination sphere defined by two I− anions and the N atom of a methyl 2-(quinolin-8-yloxyacetate ligand. In the crystal, face-to-face π–π stacking interactions, with a centroid–centroid distance of 3.563 (9 Å, are observed.

  17. TFTR alpha extraction and measurement: Development and testing of advanced alpha detectors: Final report

    International Nuclear Information System (INIS)

    Wehring, B.W.

    1988-01-01

    Advanced alpha-particle detectors made of heavy elements were investigated as alternatives to silicon surface-barrier detectors for the ''foil-neutralization technique'' of alpha-particle diagnostics in fusion reactors with high neutron backgrounds. From an extensive literature review, it was decided that HgI 2 would make a more suitable detector for alpha-particle diagnostics than other heavy element detectors such as CdTe. Thus, HgI 2 detectors were designed and fabricated. Experimental tests were performed to determine detector characteristics and detector responses to alpha particles. Radiation noise measurements were also performed using the North Carolina State University PULSTAR nuclear reactor for both the HgI 2 detectors and commercial Si(Au) surface barrier detectors. 15 refs., 1 fig

  18. Miniature probe for the delivery and monitoring of a photopolymerizable material

    Science.gov (United States)

    Schmocker, Andreas; Khoushabi, Azadeh; Schizas, Constantin; Bourban, Pierre-Etienne; Pioletti, Dominique P.; Moser, Christophe

    2015-12-01

    Photopolymerization is a common method to cure materials initially in a liquid state, such as dental implants or bone or tissue fillers. Recent advances in the development of biocompatible gel- and cement-systems open up an avenue for in situ photopolymerization. For minimally invasive surgery, such procedures require miniaturized surgical endoscopic probes to activate and control photopolymerization in situ. We present a miniaturized light probe in which a photoactive material can be (1) mixed, pressurized, and injected, (2) photopolymerized/photoactivated, and (3) monitored during the chemical reaction. The device is used to implant and cure poly(ethylene glycol) dimethacrylate-hydrogel-precursor in situ with ultraviolet A (UVA) light (365 nm) while the polymerization reaction is monitored in real time by collecting the fluorescence and Raman signals generated by the 532-nm excitation light source. Hydrogels could be delivered, photopolymerized, and monitored by the probe up to a curing depth of 4 cm. The size of the photopolymerized samples could be correlated to the fluorescent signal collected by the probe, and the reproducibility of the procedure could be demonstrated. The position of the probe tip inside a bovine caudal intervertebral disc could be estimated in vitro based on the collected fluorescence and Raman signal.

  19. An Amidochlorin-Based Colorimetric Fluorescent Probe for Selective Cu2+ Detection

    Directory of Open Access Journals (Sweden)

    Wenting Li

    2016-01-01

    Full Text Available The design and synthesis of selective and sensitive chemosensors for the quantification of environmentally and biologically important ionic species has attracted widespread attention. Amidochlorin p6 (ACP; an effective colorimetric and fluorescent probe for copper ions (Cu2+ in aqueous solution derived from methyl pheophorbide-a (MPa was designed and synthesized. A remarkable color change from pale yellow to blue was easily observed by the naked eye upon addition of Cu2+; and a fluorescence quenching was also determined. The research of fluorescent quenching of ACP-Cu2+ complexation showed the detection limit was 7.5 × 10−8 mol/L; which suggested that ACP can act as a high sensitive probe for Cu2+ and can be used to quantitatively detect low levels of Cu2+ in aqueous solution. In aqueous solution the probe exhibits excellent selectivity and sensitivity toward Cu2+ ions over other metal ions (M = Zn2+; Ni2+; Ba2+; Ag+; Co2+; Na+; K+; Mg2+; Cd2+; Pb2+; Mn2+; Fe3+; and Ca2+. The obvious change from pale yellow to blue upon the addition of Cu2+ could make it a suitable “naked eye” indicator for Cu2+.

  20. Influence of probe motion on laser probe temperature in circulating blood.

    Science.gov (United States)

    Hehrlein, C; Splinter, R; Littmann, L; Tuntelder, J R; Tatsis, G P; Svenson, R H

    1991-01-01

    The purpose of this study was to evaluate the effect of probe motion on laser probe temperature in various blood flow conditions. Laser probe temperatures were measured in an in vitro blood circulation model consisting of 3.2 nm-diameter plastic tubes. A 2.0 mm-diameter metal probe attached to a 300 microns optical quartz fiber was coupled to an argon laser. Continuous wave 4 watts and 8 watts of laser power were delivered to the fiber tip corresponding to a 6.7 +/- 0.5 and 13.2 +/- 0.7 watts power setting at the laser generator. The laser probe was either moved with constant velocity or kept stationary. A thermocouple inserted in the lateral portion of the probe was used to record probe temperatures. Probe temperature changes were found with the variation of laser power, probe velocity, blood flow, and duration of laser exposure. Probe motion significantly reduced probe temperatures. After 10 seconds of 4 watts laser power the probe temperature in stagnant blood decreased from 303 +/- 18 degrees C to 113 +/- 17 degrees C (63%) by moving the probe with a velocity of 5 cm/sec. Blood flow rates of 170 ml/min further decreased the probe temperature from 113 +/- 17 degrees C to 50 +/- 8 degrees C (56%). At 8 watts of laser power a probe temperature reduction from 591 +/- 25 degrees C to 534 +/- 36 degrees C (10%) due to 5 cm/sec probe velocity was noted. Probe temperatures were reduced to 130 +/- 30 degrees C (78%) under the combined influence of 5 cm/sec probe velocity and 170 ml/min blood flow.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Intraoperative detection of 18F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria

    International Nuclear Information System (INIS)

    Povoski, Stephen P; Chapman, Gregg J; Murrey, Douglas A; Lee, Robert; Martin, Edward W; Hall, Nathan C

    2013-01-01

    Intraoperative detection of 18 F-FDG-avid tissue sites during 18 F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of 18 F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems. Of 58 patients undergoing 18 F-FDG-directed surgery for known or suspected malignancy using gamma detection probes, we identified nine 18 F-FDG-avid tissue sites (from amongst seven patients) that were seen on same-day preoperative diagnostic PET/CT imaging, and for which each 18 F-FDG-avid tissue site underwent attempted in situ intraoperative detection concurrently using three gamma detection probe systems (K-alpha probe, and two commercially-available PET-probe systems), and then were subsequently surgical excised. The mean relative probe counting efficiency ratio was 6.9 (± 4.4, range 2.2–15.4) for the K-alpha probe, as compared to 1.5 (± 0.3, range 1.0–2.1) and 1.0 (± 0, range 1.0–1.0), respectively, for two commercially-available PET-probe systems (P < 0.001). Successful in situ intraoperative detection of 18 F-FDG-avid tissue sites was more frequently accomplished with each of the three gamma detection probes tested by using the three-sigma statistical threshold criteria method than by using the ratiometric threshold criteria method, specifically with the three-sigma statistical threshold criteria method being significantly better than the ratiometric threshold criteria method for determining probe positivity for the K-alpha probe (P = 0.05). Our results suggest that the improved probe counting efficiency of the K-alpha probe design used in conjunction with the three

  2. Ectopic mediastinal parathyroid adenoma. Detection with a radioisotopic probe and resolution with videothoracoscopy

    International Nuclear Information System (INIS)

    Moncet, Daniel; Isaac, Gabriel; Staltari, Daniel; Tomasello, Alicia; Boronat, Susana

    2006-01-01

    The case of a 66 years old woman with a diagnosis of primary hyperparathyroidism is presented. Localization to mediastinum was obtained with parathyroid scintigraphy using 99m Tc-methoxy-isobutyl-isonitrite ( 99 Tc-MIBI). The patient was successfully operated upon by means of a videothoracoscopic approach. During the procedure serum parathormone was measured before and 10 minutes after adenomectomy, showing a more than 50 % reduction from the basal level. An attempt to detect the precise site of the adenoma with a 99 Tc-MIBI probe was unsuccessful because of its proximity to the myocardium, but radioactivity was confirmed on the surgical specimen after resection. The patient's calcemia and parathormone levels became normal during the postoperative course and she remains normocalcaemic 9 months after the procedure. In our case, preoperative localization and intraoperative parathormone measurements were both very useful for confirming surgical success; the intraoperative localization with a radioactive probe was not useful, but radioactivity was confirmed after resection on the surgical specimen. The endoscopic surgical procedure with videothoracoscopy was well tolerated, less painful than a thoracotomy, and it reduced the hospitalization period. (author) [es

  3. Growth of mercuric iodide single crystals from dimethylsulfoxide

    International Nuclear Information System (INIS)

    Carlston, R.C.

    1976-01-01

    Dimethylsulfoxide is used as a solvent for the growth of red mercuric iodide (HgI 2 ) crystals for use in radiation detectors. The hygroscopic property of the solvent allows controlled amounts of water to enter into the solvent phase and diminish the large solubility of HgI 2 so that the precipitating solid collects as well-defined euhedral crystals which grow into a volume of several cc

  4. Scalable Fabrication Framework of Implantable Ultrathin and Flexible Probes with Biodegradable Sacrificial Layers.

    Science.gov (United States)

    Jiao, Xiangbing; Wang, Yuan; Qing, Quan

    2017-12-13

    For long-term biocompatibility and performance, implanted probes need to further reduce their size and mechanical stiffness to match that of the surrounding cells, which, however, makes accurate and minimally invasive insertion operations difficult due to lack of rigidity and brings additional complications in assembling and surgery. Here, we report a scalable fabrication framework of implantable probes utilizing biodegradable sacrificial layers to address this challenge. Briefly, the integrated biodegradable sacrificial layer can dissolve in physiological fluids shortly after implantation, which allows the in situ formation of functional ultrathin film structures off of the initial small and rigid supporting backbone. We show that the dissolution of this layer does not affect the viability and excitability of neuron cells in vitro. We have demonstrated two types of probes that can be used out of the box, including (1) a compact probe that spontaneously forms three-dimensional bend-up devices only after implantation and (2) an ultraflexible probe as thin as 2 μm attached to a small silicon shaft that can be accurately delivered into the tissue and then get fully released in situ without altering its shape and position because the support is fully retracted. We have obtained a >93% yield of the bend-up structure, and its geometry and stiffness can be systematically tuned. The robustness of the ultraflexible probe has been tested in tissue-mimicking agarose gels with <1% fluctuation in the test resistance. Our work provides a general strategy to prepare ultrasmall and flexible implantable probes that allow high insertion accuracy and minimal surgical damages with the best biocompatibility.

  5. A highly sensitive fluorescent probe based on BODIPY for Hg2+ in aqueous solution

    Directory of Open Access Journals (Sweden)

    ZHAO Junwei

    2016-12-01

    Full Text Available A highly sensitive fluorescent probe based on BODIPY and hydrazine for Hg2+ was designed and synthesized.This probe could detect mercury ions in aqueous solutions within 5 min.With the increase of Hg2+ mole concentration,an obvious red shift of UV-Vis absorption wavelength was observed and the fluorescence intensity significantly enhanced.It was found that the fluorescence intensity of an aqueous solution containing 0.1 μmol/L Hg2+ is much stronger than that of blank solution,which indicats that the fluorescent probe has high sensitivity.In addition,other metal ions could not cause the change of fluorescent spectra,which means this probe has good selectivity,as well.

  6. Effect of a baking soda-peroxide dentifrice on post-surgical wound healing.

    Science.gov (United States)

    Dentino, A R; Ciancio, S G; Bessinger, M; Mather, M A; Cancro, L; Fischman, S

    1995-06-01

    To investigate the effect of a baking soda-hydrogen peroxide (0.75%) dentifrice on wound healing, plaque formation, gingival inflammation, patient comfort, probing depth, and clinical attachment level following gingival flap surgery. A randomized, double-blind crossover study involving 25 patients requiring bilateral maxillary gingival flap surgery was completed. The effects of twice daily brushing with a baking soda-hydrogen peroxide dentifrice (Mentadent) or a placebo dentifrice (Crest) were observed over a 28-day post-surgical period. Gingival Index (GI), plaque index (PI), probing depth (PD), clinical attachment level (CAL) and gingival bleeding index (BI) were recorded pre-surgically and at day 28 for each surgical sextant. At days 7 and 14, soft tissue appearance/wound healing (STA) was assessed based on color and edema, PIs were determined and patient comfort was ascertained by report. Post-surgical wound healing was statistically significantly improved at day 7 with the trend continuing to day 14 when Mentadent dentifrice was used as compared to Crest dentifrice. However, there was no statistical difference in the PI values between the test and control dentifrice throughout the study. Use of Mentadent may be an effective aid in the early phase of healing following gingival flap surgery.

  7. Intraoperative detection of ¹⁸F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria.

    Science.gov (United States)

    Povoski, Stephen P; Chapman, Gregg J; Murrey, Douglas A; Lee, Robert; Martin, Edward W; Hall, Nathan C

    2013-03-04

    Intraoperative detection of (18)F-FDG-avid tissue sites during 18F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of (18)F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems. Of 58 patients undergoing (18)F-FDG-directed surgery for known or suspected malignancy using gamma detection probes, we identified nine (18)F-FDG-avid tissue sites (from amongst seven patients) that were seen on same-day preoperative diagnostic PET/CT imaging, and for which each (18)F-FDG-avid tissue site underwent attempted in situ intraoperative detection concurrently using three gamma detection probe systems (K-alpha probe, and two commercially-available PET-probe systems), and then were subsequently surgical excised. The mean relative probe counting efficiency ratio was 6.9 (± 4.4, range 2.2-15.4) for the K-alpha probe, as compared to 1.5 (± 0.3, range 1.0-2.1) and 1.0 (± 0, range 1.0-1.0), respectively, for two commercially-available PET-probe systems (P < 0.001). Successful in situ intraoperative detection of 18F-FDG-avid tissue sites was more frequently accomplished with each of the three gamma detection probes tested by using the three-sigma statistical threshold criteria method than by using the ratiometric threshold criteria method, specifically with the three-sigma statistical threshold criteria method being significantly better than the ratiometric threshold criteria method for determining probe positivity for the K-alpha probe (P = 0.05). Our results suggest that the improved probe counting efficiency of the K-alpha probe design used in conjunction with the three-sigma statistical

  8. Mercuric iodide composite films using polyamide, polycarbonate and polystyrene fabricated by casting

    International Nuclear Information System (INIS)

    Ugucioni, J.C.; Ghilardi Netto, T.; Mulato, M.

    2010-01-01

    Mercuric iodide (HgI 2 ) composite films were obtained by using the casting technique. Insulator polymers such as polyamide, polycarbonate and polystyrene were mixed to HgI 2 crystallites forming a final sub-millimeter thick self-standing film. Fabrication temperature varied from 10 to 100 o C, and total fabrication time reached at most 5 min. The larger the fabrication temperature, the thinner the film and the smaller its electrical resistivity. Electrical characterization was performed in the dark, under UV illumination and under mammographic X-ray exposure. The final properties of the films are discussed and related to fabrication conditions. The optimized composite film might be a better candidate for use as X-ray detector for medical imaging, in place of the single HgI 2 crystalline device.

  9. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    Duvaa, Uffe; Ørngreen, Rikke; Weinkouff Mathiasen, Anne-Gitte

    2013-01-01

    Mobile probing is a method, developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time and space......). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings point...... to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face). The development...

  10. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    Duvaa, Uffe; Ørngreen, Rikke; Weinkouff, Anne-Gitte

    2012-01-01

    Mobile probing is a method, which has been developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time...... and space). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings...... point to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face...

  11. A rhodamine chromene-based turn-on fluorescence probe for selectively imaging Cu2+ in living cell

    Science.gov (United States)

    Liu, Wei-Yong; Li, Hai-Ying; Lv, Hong-Shui; Zhao, Bao-Xiang; Miao, Jun-Ying

    We describe the development of a rhodamine chromene-based turn-on fluorescence probe to monitor the intracellular Cu2+ level in living cells. The new fluorescent probe with a chlorine group in chromene moiety exhibits good membrane-permeable property than previous reported because the predicted lipophilicity of present probe 4 is stronger than that of methoxyl substituted probe in our previous work (CLogP of 4: 8.313, CLogP of methoxyl substituted probe: 7.706), and a fluorescence response toward Cu2+ under physiological conditions with high sensitivity and selectivity, and facilitates naked-eye detection of Cu2+. The fluorescence intensity was remarkably increased upon the addition of Cu2+ within 1 or 2 min, while the other sixteen metal ions caused no significant effect.

  12. A monolithic microsphere-fiber probe for spatially resolved Raman spectroscopy: Application to head and neck squamous cell carcinomas

    Science.gov (United States)

    Holler, S.; Haig, B.; Donovan, M. J.; Sobrero, M.; Miles, B. A.

    2018-03-01

    The ability to identify precise cancer margins in vivo during a surgical excision is critical to the well-being of the patient. Decreased operative time has been linked to shorter patient recovery time, and there are risks associated with removing either too much or too little tissue from the surgical site. The more rapidly and accurately a surgeon can identify and excise diseased tissue, the better the prognosis for the patient. To this end, we investigate both malignant and healthy oral cavity tissue using the Raman spectroscopy, with a monolithic microsphere-fiber probe. Our results indicate that this probe has decreased the size of the analyzed area by more than an order of magnitude, as compared to a conventional fiber reflection probe. Scanning the probe across the tissues reveals variations in the Raman spectra that enable us to differentiate between malignant and healthy tissues. Consequently, we anticipate that the high spatial resolution afforded by the probe will permit us to identify tumor margins in detail, thereby optimizing tissue removal and improving patient outcomes.

  13. Dr. Harry Whelan With the Light Emitting Diode Probe

    Science.gov (United States)

    1999-01-01

    The red light from the Light Emitting Diode (LED) probe shines through the fingers of Dr. Harry Whelan, a pediatric neurologist at the Children's Hospital of Wisconsin in Milwaukee. Dr. Whelan uses the long waves of light from the LED surgical probe to activate special drugs that kill brain tumors. Laser light previously has been used for this type of surgery, but the LED light illuminates through all nearby tissues, reaching parts of tumors that shorter wavelengths of laser light carnot. The new probe is safer because the longer wavelengths of light are cooler than the shorter wavelengths of laser light, making the LED less likely to injure normal brain tissue near the tumor. Also, it can be used for hours at a time while still remaining cool to the touch. The probe was developed for photodynamic cancer therapy under a NASA Small Business Innovative Research Program grant. The program is part of NASA's Technology Transfer Department at the Marshall Space Flight Center.

  14. Evaluation of the Effect of Surgical Crown Lengthening on Periodontal Parameters

    Directory of Open Access Journals (Sweden)

    Farzane Vaziri

    2015-09-01

    Full Text Available Background: Surgical crown lengthening is needed for teeth with subgingival caries, fractured teeth, insufficient crown length, and deep subgingival margin of failed restorations. Since there is no agreement on the effects of crown lengthening surgery on gingival parameters, the purpose of this study was to evaluate periodontal parameters in patients who needed crown lengthening surgery. Methods: Twenty patients who had healthy periodontium and needed surgical crown lengthening were included in this study. After professional dental cleaning, gingival parameters including gingival index (GI, probing depth (PD, bone level (BL, and transsulcular probing (TSP were recorded in interproximal and keratinized gingiva (KG in mid buccal portion. The patients were evaluated one and three months after the surgery. Results: After one and three months of the surgery, the amount of PD reduced from 2.32 mm to 1.25 mm and 1.17 mm, respectively (P=0.001. The mean of BL reduction was 0.88 mm after one month (P=0.001, but there was no reduction between 1 month and 3 months. Amounts of KG at baseline andone month later were 4.2 mm and 2.9 mm, respectively (P=0.001, and remained at the same level up to three months. TSP significantly reduced (from 3.67 mm at baseline to 2.62 mm after 1 month, and to 2.27 mm after 3 months (P=0.001, P=0.005. Conclusion: The present  study suggests that in the presence of good oral hygiene, except BW (biological width, other parameters including PD, BL, KG, and TSP had significant changes after crown lengthening surgery in the period of 1 month and 3 months (P

  15. Development and validation of a numerical model for cross-section optimization of a multi-part probe for soft tissue intervention.

    Science.gov (United States)

    Frasson, L; Neubert, J; Reina, S; Oldfield, M; Davies, B L; Rodriguez Y Baena, F

    2010-01-01

    The popularity of minimally invasive surgical procedures is driving the development of novel, safer and more accurate surgical tools. In this context a multi-part probe for soft tissue surgery is being developed in the Mechatronics in Medicine Laboratory at Imperial College, London. This study reports an optimization procedure using finite element methods, for the identification of an interlock geometry able to limit the separation of the segments composing the multi-part probe. An optimal geometry was obtained and the corresponding three-dimensional finite element model validated experimentally. Simulation results are shown to be consistent with the physical experiments. The outcome of this study is an important step in the provision of a novel miniature steerable probe for surgery.

  16. Light Reflectance Spectroscopy to Detect Positive Surgical Margins on Prostate Cancer Specimens.

    Science.gov (United States)

    Morgan, Monica S C; Lay, Aaron H; Wang, Xinlong; Kapur, Payal; Ozayar, Asim; Sayah, Maryam; Zeng, Li; Liu, Hanli; Roehrborn, Claus G; Cadeddu, Jeffrey A

    2016-02-01

    Intraoperative frozen section analysis is not routinely performed to determine positive surgical margins at radical prostatectomy due to time requirements and unproven clinical usefulness. Light reflectance spectroscopy, which measures light intensity reflected or backscattered from tissues, can be applied to differentiate malignant from benign tissue. We used a novel light reflectance spectroscopy probe to evaluate positive surgical margins on ex vivo radical prostatectomy specimens and correlate its findings with pathological examination. Patients with intermediate to high risk disease undergoing radical prostatectomy were enrolled. Light reflectance spectroscopy was performed on suspected malignant and benign prostate capsule immediately following organ extraction. Each light reflectance spectroscopy at 530 to 830 nm was analyzed and correlated with pathological results. A regression model and forward sequential selection algorithm were developed for optimal feature selection. Eighty percent of light reflectance spectroscopy data were selected to train a logistic regression model, which was evaluated by the remaining 20% data. This was repeated 5 times to calculate averaged sensitivity, specificity and accuracy. Light reflectance spectroscopy analysis was performed on 17 ex vivo prostate specimens, on which a total of 11 histologically positive and 22 negative surgical margins were measured. Two select features from 700 to 830 nm were identified as unique to malignant tissue. Cross-validation when performing the predictive model showed that the optical probe predicted positive surgical margins with 85% sensitivity, 86% specificity, 86% accuracy and an AUC of 0.95. Light reflectance spectroscopy can identify positive surgical margins accurately in fresh ex vivo radical prostatectomy specimens. Further study is required to determine whether such analysis may be used in real time to improve surgical decision making and decrease positive surgical margin rates

  17. Surgical Treatment of Peri-Implantitis: A 17-Year Follow-Up Clinical Case Report

    Directory of Open Access Journals (Sweden)

    Fabrizio Bassi

    2015-01-01

    Full Text Available The purpose of the present case report was to describe the surgical treatment of a peri-implantitis lesion associated with a regenerative approach. A 48-year-old patient came to authors’ attention 36 months after the placement of a dental implant (ITI-Bonefit Straumann, Waldenburg, Switzerland in position 46. A swelling of the peri-implant soft tissues was observed, associated with bleeding on probing and probing depth > 10 mm. A significant peri-implant bone loss was clearly visible on the periapical radiograph. A nonsurgical periodontal supportive therapy was firstly conducted to reduce the inflammation, followed by the surgical treatment of the defect. After mechanical and chemical decontamination with tetracycline solution, a regenerative approach consisting in the application of deproteinized bovine bone mineral (Bio-Oss, Geistlich Pharma AG, Wolhusen, Switzerland and a collagen membrane (Bio-Gide, Geistlich Pharma AG, Wolhusen, Switzerland was performed. An antibiotic therapy was associated with the treatment. The 17-year follow-up showed a physiological probing depth with no clinical signs of peri-implant inflammation and bleeding on probing. No further radiographic bone loss was observed. The treatment described in the present case report seemed to show improved clinical results up to a relevant follow-up period.

  18. A molecular dual fluorescence-ON probe for Mg2+ and Zn2+: Higher selectivity towards Mg2+ over Zn2+ in a mixture

    International Nuclear Information System (INIS)

    Maity, Shubhra Bikash; Bharadwaj, Parimal K.

    2014-01-01

    A Schiff base incorporating a coumarin fluorophore has been synthesized from easily available materials and is characterized by X-ray crystallography and other techniques. The probe serves as a dual analyte sensor and quantifies Mg 2+ and Zn 2+ ions by emission enhancement at different wavelengths without interference from a host of biologically relevant alkali/alkaline earth and transition metal ions. In presence of Mg 2+ the light yellow color of the probe in methanol changes to yellow–orange while in presence of Zn 2+ ion it changes to orange and hence can be detected through naked eye. The probe selectively gives emission of Mg 2+ when Zn 2+ ion is also present. - Highlights: • A Schiff base incorporating a coumarin fluorophore has been synthesized. • It acts as a dual analyte sensor and quantifies Mg 2+ and Zn 2+ ions by emission enhancement at different wavelengths. • It shows excellent selectivity for Mg 2+ ion in presence of alkali, alkaline earth metals as well as first row transition metals

  19. CONVERGENT SYNTHESIS AND EVALUATION OF 18F-LABELED AZULENIC COX2 PROBES FOR CANCER IMAGING

    Directory of Open Access Journals (Sweden)

    Donald D. Nolting

    2013-01-01

    Full Text Available The overall objectives of this research are to (i develop azulene-based PET probes and (ii image COX2 as a potential biomarker of breast cancer. Several lines of research have demonstrated that COX2 is overexpressed in breast cancer and that its presence correlates with poor prognoses. While other studies have reported that COX2 inhibition can be modulated and used beneficially as a chemopreventive strategy in cancer, no viable mechanism for achieving that approach has yet been developed. This shortfall could be circumvented through in vivo imaging of COX2 activity, particularly using sensitive imaging techniques such as PET. Toward that goal, our laboratory focuses on the development of novel 18F-labled COX2 probes. We began the synthesis of the probes by transforming tropolone into a lactone, which was subjected to an [8+2] cycloaddition reaction to yield 2-methylazulene as the core ring of the probe. After exploring numerous synthetic routes, the final target molecule and precursor PET compounds were prepared successfully using convergent synthesis. Conventional 18F labeling methods caused precursor decomposition, which prompted us to hypothesize that the acidic protons of the methylene moiety between the azulene and thiazole rings were readily abstracted by a strong base such as potassium carbonate. Ultimately, this caused the precursors to disintegrate. This observation was supported after successfully using an 18F labeling strategy that employed a much milder phosphate buffer. The 18F-labeled COX2 probe was tested in a breast cancer xenograft mouse model. The data obtained via successive whole-body PET/CT scans indicated probe accumulation and retention in the tumor. Overall, the probe was stable in vivo and no defluorination was observed. A biodistribution study and Western blot analysis corroborate with the imaging data. In conclusion, this novel COX2 PET probe was shown to be a promising agent for cancer imaging and deserves further

  20. EGR distribution and fluctuation probe based on CO.sub.2 measurements

    Science.gov (United States)

    Parks, II, James E; Partridge, Jr., William P; Yoo, Ji Hyung

    2015-04-07

    A diagnostic system having a single-port EGR probe and a method for using the same. The system includes a light source, an EGR probe, a detector and a processor. The light source may provide a combined light beam composed of light from a mid-infrared signal source and a mid-infrared reference source. The signal source may be centered at 4.2 .mu.m and the reference source may be centered at 3.8 .mu.m. The EGR probe may be a single-port probe with internal optics and a sampling chamber with two flow cells arranged along the light path in series. The optics may include a lens for focusing the light beam and a mirror for reflecting the light beam received from a pitch optical cable to a catch optical cable. The signal and reference sources are modulated at different frequencies, thereby allowing them to be separated and the signal normalized by the processor.

  1. Implantable oxygen microelectrode suitable for medium-term investigations of post-surgical tissue hypoxia and changes in tumor tissue oxygenation produced by radiotherapy

    International Nuclear Information System (INIS)

    Burke, T.R.; Johnson, R.J.; Krishnamsetty, C.B.; Sako, K.; Karakousis, C.; Wojtas, F.

    1980-01-01

    Teflon-covered platinum oxygen probes were used to monitor tissue oxygen levels in post-surgical cancer patients and those treated with radiotherapy. Progressive wound healing was usually accompanied by a decrease in tissue pO2. Radiotherapy produced a slight increase in pO2 while hyperthermia effected a significant increase in the oxygen level during 100% oxygen breathing

  2. Crystal growth and applications of mercuric iodide. Report S-242-TP

    International Nuclear Information System (INIS)

    Schieber, M.; Roth, M.; Schnepple, W.F.

    1983-01-01

    A brief summary is given of a paper which discusses the crystal growth of mercuric iodide, a high-Z wide bandgap semiconductor suitable as a low noise, room temperature x-ray and gamma-ray detector. The paper summarized also reviews the state-of-the-art of the synthesis and purification of the starting material, mechanical properties and dislocation structure of HgI 2 , and recent success in the development of thick HgI 2 spectrometers

  3. Probe-guided surgery: metastases of a papillary thyroid carcinoma. Surgical Excision

    International Nuclear Information System (INIS)

    Kowadlo, A.R.; Zund, S.; Perez Irigoyen, C.

    2008-01-01

    A male patient with papillary thyroid cancer -follicular variety- is chosen to be presented. After thyroidectomy, lymphadenectomy and therapeutic dose of radioiodine treatments, cancer relapse was observed. After thyrotrophin suppressive therapy with l-thyroxine, a high serum thyroglobulin concentration was observed. The Ultrasonography (US) and Magnetic Resonance (MR) images showed visible node structures in the neck. This node structures were probably going to concentrate I-131 as seen in the fi rst whole body scan after therapeutic dose. Therefore a radio-guided surgery was planned as the best choice. (Institute Gustave Roussy protocol). A therapeutic dose of radioiodine (I-131) was given and up to the 4th day a whole body scan was performed. In the 5th day a gamma- probe-guided surgery was performed as well, and localized metastatic foci in the pretracheal region and under right recurrent laryngeal nerve. No other foci were identified ed with the probe at surgery. Forty eight hours after surgery a new whole-body scan was made again. The procedure was successful. The metastatic lesions were completely dissected. The last whole body scan showed that radioiodine concentration had disappeared at all. Forty fi ve days and three months after surgery under levothyroxine treatment, the serum thyroglobulin level concentration decrease to very low values. (authors) [es

  4. A new method for intraoperative localization of epilepsy focus by means of a gamma probe

    International Nuclear Information System (INIS)

    Carneiro Filho, Omar; Vilela Filho, Osvaldo; Ragazzo, Paulo Cesar; Fonseca, Lea Mirian Barbosa da

    2014-01-01

    Objective: to evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and methods: two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results: in patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion: the comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy. (author)

  5. Position of probe determines prognostic information of brain tissue PO2 in severe traumatic brain injury.

    Science.gov (United States)

    Ponce, Lucido L; Pillai, Shibu; Cruz, Jovany; Li, Xiaoqi; Julia, H; Gopinath, Shankar; Robertson, Claudia S

    2012-06-01

    Monitoring brain tissue PO2 (PbtO2) is part of multimodality monitoring of patients with traumatic brain injury (TBI). However, PbtO2 measurement is a sampling of only a small area of tissue surrounding the sensor tip. To examine the effect of catheter location on the relationship between PbtO2 and neurological outcome. A total of 405 patients who had PbtO2 monitoring as part of standard management of severe traumatic brain injury were studied. The relationships between probe location and resulting PbtO2 and outcome were examined. When the probe was located in normal brain, PbtO2 averaged 30.8 ± 18.2 compared with 25.6 ± 14.8 mm Hg when placed in abnormal brain (P < .001). Factors related to neurological outcome in the best-fit logistic regression model were age, PbtO2 probe position, postresuscitation motor Glasgow Coma Scale score, and PbtO2 trend pattern. Although average PbtO2 was significantly related to outcome in univariate analyses, it was not significant in the final logistic model. However, the interaction between PbtO2 and probe position was statistically significant. When the PbtO2 probe was placed in abnormal brain, the average PbtO2 was higher in those with a favorable outcome, 28.8 ± 12.0 mm Hg, compared with those with an unfavorable outcome, 19.5 ± 13.7 mm Hg (P = .01). PbtO2 and outcome were not related when the probe was placed in normal-appearing brain. These results suggest that the location of the PbtO2 probe determines the PbtO2 values and the relationship of PbtO2 to neurological outcome.

  6. Introduction to fifth international workshop on mercuric iodide nuclear radiation detectors

    International Nuclear Information System (INIS)

    Schieber, M.

    1982-01-01

    Mercuric iodide is a wide bandgap semiconductor, with Eg approx. = 2.14 eV at room temperature. Therefore, HgI 2 is totally different from the well-studied, narrower gap, elemental semiconductors such as Si and Ge, and also different in its physical and chemical properties from the known semiconductor binary zinc-blend compounds such as GaAs or InP. The purpose of studies in the last decade was to further our understanding of HgI 2 ; recent progress is reported

  7. PROBING TRAPPIST-1-LIKE SYSTEMS WITH K2

    Energy Technology Data Exchange (ETDEWEB)

    Demory, Brice-Olivier; Queloz, Didier; Gillen, Ed [Astrophysics Group, Cavendish Laboratory, J.J. Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Alibert, Yann [Physikalisches Institut and Center for Space and Habitability, Universität Bern, 3012 Bern (Switzerland); Gillon, Michael, E-mail: bod21@cam.ac.uk [Institut d’Astrophysique et de Geophysique, Universite de Liege, Allee du 6 Aout 17, Bat. B5C, B-4000 Liege (Belgium)

    2016-07-10

    The search for small planets orbiting late M dwarfs holds the promise of detecting Earth-size planets for which their atmospheres could be characterized within the next decade. The recent discovery of TRAPPIST-1 entertains hope that these systems are common around hosts located at the bottom of the main sequence. In this Letter, we investigate the ability of the repurposed Kepler mission ( K2 ) to probe planetary systems similar to TRAPPIST-1. We perform a consistent data analysis of 189 spectroscopically confirmed M5.5 to M9 late M dwarfs from Campaigns 1–6 to search for planet candidates and inject transit signals with properties matching TRAPPIST-1b and c. We find no transiting planet candidates across our K2 sample. Our injection tests show that K2 is able to recover both TRAPPIST-1 planets for 10% of the sample only, mainly because of the inefficient throughput at red wavelengths resulting in Poisson-limited performance for these targets. Increasing injected planetary radii to match GJ 1214b’s size yields a recovery rate of 70%. The strength of K2 is its ability to probe a large number of cool hosts across the different campaigns, out of which the recovery rate of 10% may turn into bona fide detections of TRAPPIST-1-like systems within the next two years.

  8. Redox Probing Study of the Potential Dependence of Charge Transport Through Li2O2

    DEFF Research Database (Denmark)

    Knudsen, Kristian Bastholm; Luntz, Alan C.; Jensen, Søren Højgaard

    2015-01-01

    -of-the-art Liion technologies and the demand placed on batteries by technologies such as electrical vehicles. Here we present a redox probing study of the charge transfer across the main deposition product lithium peroxide, Li2O2, in the Li−O2 battery using outer-sphere redox shuttles. The change in heterogeneous......In the field of energy storage devices the pursuit for cheap, high energy density, reliable secondary batteries is at the top of the agenda. The Li−O2 battery is one of the possible technologies that, in theory, should be able to close the gap, which exists between the present state...... electron transfer exchange rate as a function of the potential and the Li2O2 layer thickness (∼depth-of-discharge) was determined using electrochemical impedance spectroscopy. The attenuation of the electron transfer exchange rate with film thickness is dependent on the probing potential, providing...

  9. Electrospun nanofiber based colorimetric probe for rapid detection of Fe{sup 2+} in water

    Energy Technology Data Exchange (ETDEWEB)

    Ondigo, D.A. [Department of Chemistry, Rhodes University, P.O. Box 94, Grahamstown 6140 (South Africa); Tshentu, Z.R. [Department of Chemistry, Rhodes University, P.O. Box 94, Grahamstown 6140 (South Africa); Department of Chemistry, Nelson Mandela Metropolitan University, P.O. Box 77000, Port Elizabeth, 6031 (South Africa); Torto, N., E-mail: N.Torto@ru.ac.za [Department of Chemistry, Rhodes University, P.O. Box 94, Grahamstown 6140 (South Africa)

    2013-12-04

    Graphical abstract: -- Highlights: •Colorimetric probe for the detection of Fe{sup 2+} was developed. •Polymeric electrospun nanofibers were used as host for the signaling reagent. •The functionalized electrospun nanofibers exhibited a selective color change in the presence of Fe{sup 2+}. •The mechanism was based on spin crossover (SCO) from high spin Fe{sup 2+} to low spin Fe{sup 2+} upon interaction with the embedded ligand. -- Abstract: An imidazole derivative, 2-(2′-pyridyl)imidazole (PIMH), was developed as a colorimetric probe for the qualitative analysis of Fe{sup 2+} in aqueous solution. PIMH was then used to post-functionalize poly(vinylbenzyl chloride) (PVBC) nanofibers after electrospinning so as to afford a solid state colorimetric probe. Upon treatment with Fe{sup 2+} the probe displayed a distinctive color change both in liquid and solid platforms. The linear dynamic range for the colorimetric determination of Fe{sup 2+} was 0.0988–3.5 μg mL{sup −1}. The ligand showed a high chromogenic selectivity for Fe{sup 2+} over other cations with a detection limit of 0.102 μg mL{sup −1} in solution (lower than the WHO drinking water guideline limit of 2 mg L{sup −1}), and 2 μg mL{sup −1} in the solid state. The concentration of Fe{sup 2+} in a certified reference material (Iron, Ferrous, 1072) was found to be 2.39 ± 0.01 mg L{sup −1}, which was comparable with the certified value of 2.44 ± 0.12 mg L{sup −1}. Application of the probe to real samples spiked with Fe{sup 2+} achieved recoveries of over 97% confirming accuracy of the method and its potential for on-site monitoring.

  10. A Bright Future for Precision Medicine: Advances in Fluorescent Chemical Probe Design and Their Clinical Application.

    Science.gov (United States)

    Garland, Megan; Yim, Joshua J; Bogyo, Matthew

    2016-01-21

    The Precision Medicine Initiative aims to use advances in basic and clinical research to develop therapeutics that selectively target and kill cancer cells. Under the same doctrine of precision medicine, there is an equally important need to visualize these diseased cells to enable diagnosis, facilitate surgical resection, and monitor therapeutic response. Therefore, there is a great opportunity for chemists to develop chemically tractable probes that can image cancer in vivo. This review focuses on recent advances in the development of optical probes, as well as their current and future applications in the clinical management of cancer. The progress in probe development described here suggests that optical imaging is an important and rapidly developing field of study that encourages continued collaboration among chemists, biologists, and clinicians to further refine these tools for interventional surgical imaging, as well as for diagnostic and therapeutic applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Surgical Robotics Research in Cardiovascular Disease

    Energy Technology Data Exchange (ETDEWEB)

    Pohost, Gerald M; Guthrie, Barton L; Steiner, Charles

    2008-02-29

    This grant is to support a research in robotics at three major medical centers: the University of Southern California-USC- (Project 1); the University of Alabama at Birmingham-UAB-(Project 2); and the Cleveland Clinic Foundation-CCF-(Project 3). Project 1 is oriented toward cardiovascular applications, while projects 2 and 3 are oriented toward neurosurgical applications. The main objective of Project 1 is to develop an approach to assist patients in maintaining a constant level of stress while undergoing magnetic resonance imaging or spectroscopy. The specific project is to use handgrip to detect the changes in high energy phosphate metabolism between rest and stress. The high energy phosphates, ATP and phosphocreatine (PCr) are responsible for the energy of the heart muscle (myocardium) responsible for its contractile function. If the blood supply to the myocardium in insufficient to support metabolism and contractility during stress, the high energy phosphates, particularly PCr, will decrease in concentration. The high energy phosphates can be tracked using phosphorus-31 magnetic resonance spectroscopy ({sup 31}P MRS). In Project 2 the UAB Surgical Robotics project focuses on the use of virtual presence to assist with remote surgery and surgical training. The goal of this proposal was to assemble a pilot system for proof of concept. The pilot project was completed successfully and was judged to demonstrate that the concept of remote surgical assistance as applied to surgery and surgical training was feasible and warranted further development. The main objective of Project 3 is to develop a system to allow for the tele-robotic delivery of instrumentation during a functional neurosurgical procedure (Figure 3). Instrumentation such as micro-electrical recording probes or deep brain stimulation leads. Current methods for the delivery of these instruments involve the integration of linear actuators to stereotactic navigation systems. The control of these delivery

  12. Surgical Robotics Research in Cardiovascular Disease

    International Nuclear Information System (INIS)

    Pohost, Gerald M; Guthrie, Barton L; Steiner, Charles

    2008-01-01

    This grant is to support a research in robotics at three major medical centers: the University of Southern California-USC- (Project 1); the University of Alabama at Birmingham-UAB-(Project 2); and the Cleveland Clinic Foundation-CCF-(Project 3). Project 1 is oriented toward cardiovascular applications, while projects 2 and 3 are oriented toward neurosurgical applications. The main objective of Project 1 is to develop an approach to assist patients in maintaining a constant level of stress while undergoing magnetic resonance imaging or spectroscopy. The specific project is to use handgrip to detect the changes in high energy phosphate metabolism between rest and stress. The high energy phosphates, ATP and phosphocreatine (PCr) are responsible for the energy of the heart muscle (myocardium) responsible for its contractile function. If the blood supply to the myocardium in insufficient to support metabolism and contractility during stress, the high energy phosphates, particularly PCr, will decrease in concentration. The high energy phosphates can be tracked using phosphorus-31 magnetic resonance spectroscopy ( 31 P MRS). In Project 2 the UAB Surgical Robotics project focuses on the use of virtual presence to assist with remote surgery and surgical training. The goal of this proposal was to assemble a pilot system for proof of concept. The pilot project was completed successfully and was judged to demonstrate that the concept of remote surgical assistance as applied to surgery and surgical training was feasible and warranted further development. The main objective of Project 3 is to develop a system to allow for the tele-robotic delivery of instrumentation during a functional neurosurgical procedure (Figure 3). Instrumentation such as micro-electrical recording probes or deep brain stimulation leads. Current methods for the delivery of these instruments involve the integration of linear actuators to stereotactic navigation systems. The control of these delivery devices

  13. Post-exercise appetite was affected by fructose content but not glycemic index of pre-exercise meals.

    Science.gov (United States)

    Sun, Feng-Hua; Wong, Stephen Heung-Sang; Liu, Zhi-Gang

    2016-01-01

    The purpose of this study was to investigate whether both glycemic index (GI) and breakfast fructose content affect appetite during the postprandial period and recovery period after 1 hr of brisk walking. Ten healthy young men (age: 21.7 ± 1.5 y, body mass index: 20.9 ± 1.1 kg∙m(-2), VO2max: 53.7 ± 3.7 mL∙kg(-1)∙min(-1)) completed 1 hr of brisk walking at 46% VO2max 2 hr after eating one of three isocaloric breakfasts: a low-GI breakfast not including fructose content (LGI), a low-GI breakfast including fructose beverage (LGIF) and a high-GI breakfast (HGI). All breakfasts provided 1.0 g∙kg(-1) body weight carbohydrates, and the calculated GI values for the three breakfasts were 41, 39, and 72, respectively. In the LGIF and HGI trials, approximately 25% of participants' energy was derived from either fructose or glucose beverage. Appetite scores were measured every 30 min during the 2-hr postprandial period and 1-hr recovery period. During the postprandial period, the incremental areas under the blood response curve values of glucose and insulin were higher in the HGI trial, compared with those in the LGI and LGIF trials. At 30 and 60 min during the recovery period, the appetite scores were lower in the LGIF trial than those in the LGI and HGI trials. No differences were observed between the LGI and HGI trials. Breakfast fructose content, rather than GI, seems to affect appetite during the recovery period after 1 hr of brisk walking. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Dynamics of Exciton Relaxation in LH2 Antenna Probed by Multipulse Nonlinear Spectroscopy

    NARCIS (Netherlands)

    Novoderezhkin, V.I.; Cohen Stuart, T.A.; van Grondelle, R.

    2011-01-01

    We explain the relaxation dynamics in the LH2-B850 antenna as revealed by multipulse pump - dump - probe spectroscopy (Th. A. Cohen StuartM. VengrisV. I. NovoderezhkinR. J. CogdellC. N. HunterR. van Grondelle, submitted). The theory of pump - dump - probe response is evaluated using the doorway -

  15. Cu2+-labeled dansyl compounds as fluorescent and PET probes for imaging apoptosis.

    Science.gov (United States)

    Han, Junyan; Wang, Xukui; Yu, MeiXiang

    2016-11-15

    Compound DNSTT-Cu 2+ , a novel chelate of Cu 2+ with DOTA conjugated to a fluorescent dansyl fragment, is developed for imaging cell apoptosis. Apoptotic U-87MG cells could be selectively visualized by the fluorescence of DNSTT-Cu 2+ from cytoplasm of cells, confirmed by the fluorescence of apoptosis cells co-labeled with Alexa Fluor 568-labeled annexin V, a conventional probe for selectively labeling membranes of apoptosis cells. A radioactive 64 Cu 2 + analog, DNSTT- 64 Cu 2+ , was easily synthesized, providing a potential PET probe for imaging apoptosis in vivo. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. A new rhodamine-based fluorescent probe for the discrimination of Fe"3"+ from Fe"2"+

    International Nuclear Information System (INIS)

    You, Qi Hua; Huang, Hua Bin; Zhuang, Zhi Xia; Wang, Xiao Ru; Chan, Wing Hong

    2016-01-01

    A new rhodamine-based fluorescent probe for the discrimination of Fe"3"+ from Fe"2"+ has been designed and investigated. The probe shows an immediate visual color change in response to Fe"3"+ and Cu"2"+, while only Fe"3"+ triggers the fluorescent change of the probe. The existence of large amount of other metal ions shows negligible interference in the detection of Fe"3"+. The association constant K_a_s_s of 4.64 × 10"8 M"-"2 (R"2 = 0.994) and 5.38 × 10"8 M"-"2 (R"2 = 0.991) of the complex was derived from UV/Vis and fluorescence titration assuming 1:2 stoichiometry of probe–Fe"3"+ complex, respectively

  17. Convergent synthesis and evaluation of {sup 18}F-labeled azulenic COX2 probes for cancer imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nolting, Donald D.; Nickels, Michael; Tantawy, Mohammed N.; Yu, James Y. H.; Xie, Jingping [Department of Radiology, Institute of Imaging Science, Vanderbilt University, Nashville, TN (United States); Peterson, Todd E. [Department of Radiology, Institute of Imaging Science, Vanderbilt University, Nashville, TN (United States); Department of Physics and Astronomy, Vanderbilt University, Nashville, TN (United States); Crews, Brenda C. [Department of Chemistry, Vanderbilt University, Nashville, TN (United States); Vanderbilt Institute of Chemical Biology, Nashville, TN (United States); Marnett, Larry [Department of Chemistry, Vanderbilt University, Nashville, TN (United States); Vanderbilt Institute of Chemical Biology, Nashville, TN (United States); Vanderbilt Ingram Cancer Center, Vanderbilt University, Nashville, TN (United States); Gore, John C. [Department of Radiology, Institute of Imaging Science, Vanderbilt University, Nashville, TN (United States); Department of Physics and Astronomy, Vanderbilt University, Nashville, TN (United States); Vanderbilt Ingram Cancer Center, Vanderbilt University, Nashville, TN (United States); Department of Biomedical Engineering, Vanderbilt University, Nashville, TN (United States); Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, TN (United States); Pham, Wellington, E-mail: wellington.pham@vanderbilt.edu [Department of Radiology, Institute of Imaging Science, Vanderbilt University, Nashville, TN (United States); Vanderbilt Institute of Chemical Biology, Nashville, TN (United States); Vanderbilt Ingram Cancer Center, Vanderbilt University, Nashville, TN (United States); Department of Biomedical Engineering, Vanderbilt University, Nashville, TN (United States); Department of Neuroscience, Vanderbilt University, Nashville, TN (United States)

    2013-01-03

    The overall objectives of this research are to (i) develop azulene-based positron emission tomography (PET) probes and (ii) image COX2 as a potential biomarker of breast cancer. Several lines of research have demonstrated that COX2 is overexpressed in breast cancer and that its presence correlates with poor prognoses. While other studies have reported that COX2 inhibition can be modulated and used beneficially as a chemopreventive strategy in cancer, no viable mechanism for achieving that approach has yet been developed. This shortfall could be circumvented through in vivo imaging of COX2 activity, particularly using sensitive imaging techniques such as PET. Toward that goal, our laboratory focuses on the development of novel {sup 18}F-labled COX2 probes. We began the synthesis of the probes by transforming tropolone into a lactone, which was subjected to an [8 + 2] cycloaddition reaction to yield 2-methylazulene as the core ring of the probe. After exploring numerous synthetic routes, the final target molecule and precursor PET compounds were prepared successfully using convergent synthesis. Conventional {sup 18}F labeling methods caused precursor decomposition, which prompted us to hypothesize that the acidic protons of the methylene moiety between the azulene and thiazole rings were readily abstracted by a strong base such as potassium carbonate. Ultimately, this caused the precursors to disintegrate. This observation was supported after successfully using an {sup 18}F labeling strategy that employed a much milder phosphate buffer. The {sup 18}F-labeled COX2 probe was tested in a breast cancer xenograft mouse model. The data obtained via successive whole-body PET/CT scans indicated probe accumulation and retention in the tumor. Overall, the probe was stable in vivo and no defluorination was observed. A biodistribution study and Western blot analysis corroborate with the imaging data. In conclusion, this novel COX2 PET probe was shown to be a promising agent for

  18. Effects of Mixed Isoenergetic Meals on Fat and Carbohydrate Metabolism during Exercise in Older Men

    Directory of Open Access Journals (Sweden)

    Minoo Bassami

    2011-01-01

    Full Text Available The present study was designed to investigate the effects of four different meals on fat and CHO metabolism during subsequent exercise in elderly males. Eight healthy males (age: 63.3 ± 5.2 years reported to the physiology laboratory on four separate occasions, each of which was allocated for the performance of a 30-minute exercise on a cycle ergometer at 60% ̇VO2max after having normal (N, high fat (HF, high carbohydrate high glycaemic index (HGI and high carbohydrate low glycaemic index (LGI meals. Fat oxidation during exercise after the meals (HF=0.26±0.04 g/min; N=0.21±0.04 g/min; HGI=0.22±0.03 g/min; LGI=0.19±0.03 g/min was not significant (>.05, and neither were the rates of carbohydrate oxidation (N=1.79±0.28, HF=1.58±0.22, HGI=1.68±0.22, and LGI=1.77±0.21 g/m. NEFA concentration increased after HF (<.05 but decreased after HGI and LGI (<.05. Glucose concentration decreased as a result of exercise after HF, and LGI (<.05 whereas insulin concentration decreased significantly during exercise after N, HF, and HGI (<.05. It can be concluded that, in elderly males, feeding isoenergetic meals containing different proportions of carbohydrate and fat do not significantly alter oxidation of fat and CHO during exercise in spite of changes in some circulating metabolites.

  19. Surgical placement of a wireless telemetry device for cardiovascular studies of bovine calves [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Joseph M. Neary

    2017-07-01

    Full Text Available Background: Domestic cattle (Bos taurus are naturally susceptible to hypoxia-induced pulmonary arterial hypertension; consequently, the bovine calf has been used with considerable success as an animal model of the analogous human condition. Studies to date, however, have relied on instantaneous measurements of pressure and cardiac output. Here, we describe the surgical technique for placement of a fully implantable wireless biotelemetry device in a bovine calf for measurement of pulmonary arterial and left ventricular pressures, right ventricular output, and electrocardiogram. Methods: Three, 2-month old bovine calves underwent left-sided thoracotomies. A transit-time flow probe was placed around the pulmonary artery and solid-state pressure catheters inserted into the pulmonary artery and left ventricle. Biopotential leads were secured to the epicardium. The implant body was secured subcutaneously, dorso-caudal to the incision. Results: The implant and sensors were successfully placed in two of the three calves. One calf died from ventricular fibrillation following left ventricular puncture prior to pressure sensor insertion. Anatomical discrepancies meant that either 4th or 5th rib was removed. The calves recovered quickly with minimal complications that included moderate dyspnea and subcutaneous edema. Conclusions: Left thoracotomy is a viable surgical approach for wireless biotelemetry studies of bovine calf cardiovascular function. The real-time, contemporaneous collection of cardiovascular pressures and output, permits pathophysiological studies in a naturally susceptible, large animal model of pulmonary arterial hypertension.

  20. High gradient lens for charged particle beam

    Science.gov (United States)

    Chen, Yu-Jiuan

    2014-04-29

    Methods and devices enable shaping of a charged particle beam. A dynamically adjustable electric lens includes a series of alternating a series of alternating layers of insulators and conductors with a hollow center. The series of alternating layers when stacked together form a high gradient insulator (HGI) tube to allow propagation of the charged particle beam through the hollow center of the HGI tube. A plurality of transmission lines are connected to a plurality of sections of the HGI tube, and one or more voltage sources are provided to supply an adjustable voltage value to each transmission line of the plurality of transmission lines. By changing the voltage values supplied to each section of the HGI tube, any desired electric field can be established across the HGI tube. This way various functionalities including focusing, defocusing, acceleration, deceleration, intensity modulation and others can be effectuated on a time varying basis.

  1. Techniques for Optimizing Surgical Scars, Part 2: Hypertrophic Scars and Keloids.

    Science.gov (United States)

    Potter, Kathryn; Konda, Sailesh; Ren, Vicky Zhen; Wang, Apphia Lihan; Srinivasan, Aditya; Chilukuri, Suneel

    2017-01-01

    Surgical management of benign or malignant cutaneous tumors may result in noticeable scars that are of great concern to patients, regardless of sex, age, or ethnicity. Techniques to optimize surgical scars are discussed in this three-part review. Part 2 focuses on scar revision for hypertrophic and keloids scars. Scar revision options for hypertrophic and keloid scars include corticosteroids, bleomycin, fluorouracil, verapamil, avotermin, hydrogel scaffold, nonablative fractional lasers, ablative and fractional ablative lasers, pulsed dye laser (PDL), flurandrenolide tape, imiquimod, onion extract, silicone, and scar massage.

  2. Somatostatin receptor scintigraphy and intraoperative gamma probe detection in the localisation and treatment of pancreatic insulinoma

    International Nuclear Information System (INIS)

    Loh, Nelson K.; Macdonald, William B.; Dunne, Marina L.; Rao, Sudhakar

    2009-01-01

    Full text: Aims: We report a case of insulinoma that was successfully enucleated under radio-guidance after an initial unsuccessful laparotomy. This case highlights the utility of Somatostatin Receptor Scintigraphy (SRS) and gamma probe in the localisation and treatment of neuroendocrine tumours. Methods: The patient presented with recurrent hypoglycaemia. An abdominal CT scan identified a lesion in the uncinate process of the pancreas, however, laparotomy with use of intraoperative ultrasound failed to localise the lesion. SRS with SPECTICT was then requested by the surgical team with a view to radio-guided surgery. Results: SRS demonstrated an octreotide-avid tumour in the posterior uncinate process of the pancreas, and confirmed suitability for radio-guided surgery. At re-exploration, the surgeon was again unable to palpate the lesion or localise it with intraoperative ultrasound, however, the lesion was successfully detected and removed with the use of a gamma probe. A postoperative SRS confirmed complete excision and histopathology was diagnostic of insulinoma. Conclusion: This case highlights the utility of SRS in the intraoperative localisation and surgical excision of neuroendocrine tumours. The lesion was unable to be localised clinically or with intraoperative ultrasound but was successfully detected with scintigraphic techniques. The surgical team acknowledge that the use of a gamma probe enabled enucleation of the insulinoma, which obviated the need for an invasive Whipple's procedure.

  3. A dansyl-rhodamine ratiometric fluorescent probe for Hg2+ based on FRET mechanism.

    Science.gov (United States)

    Xie, Puhui; Guo, Fengqi; Wang, Lingyu; Yang, Sen; Yao, Denghui; Yang, Guoyu

    2015-03-01

    Based on resonance energy transfer (FRET) from dansyl to rhodamine 101, a new fluorescent probe (compound 1) containing rhodamine 101 and a dansyl unit was synthesized for detecting Hg(2+) through ratiometric sensing in DMSO aqueous solutions. This probe shows a fast, reversible and selective response toward Hg(2+) in a wide pH range. Hg(2+) induced ring-opening reactions of the spirolactam rhodamine moiety of 1, leading to the formation of fluorescent derivatives that can serve as the FRET acceptors. Very large stokes shift (220 nm) was observed in this case. About 97-fold increase in fluorescence intensity ratio was observed upon its binding with Hg(2+).

  4. Fluorescent probe encapsulated hydrogel microsphere for selective and reversible detection of Hg{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Song, Zhenhu; Wang, Fang; Qiang, Jian; Zhang, Zhijie; Chen, Yahui; Wang, Yong; Zhang, Wei; Chen, Xiaoqiang

    2017-03-15

    We developed a simple and sensitive hydrogel sensor in the form of microspheres by using fluorescence probe encapsulated within a hydrogel matrix for the detection of Hg{sup 2+}. The traditional fluorescence probes suspended in solution are not transportable and recoverable. To overcome these disadvantages, we devised poly(ethylene glycol) diacrylate-based hydrogel microspheres in which fluorescence probe (R19S) was embedded at high density. The functionalized hydrogel microspheres were prepared by combining a microfluidic device with UV light. The hydrogel microspheres-based sensor exhibited good selectivity to Hg{sup 2+} among various metal ions and high sensitivity with a detection limit of 90 nM. Furthermore, after binding with Hg{sup 2+}, the R19S encapsulated hydrogel microspheres can be separated from testing samples easily and treated with the solution containing KI to remove Hg{sup 2+} and realize reusable detection. The current work may offer a new method for Hg{sup 2+} recognition with a more efficient manner.

  5. Synthesis of a Cu2+-Selective Probe Derived from Rhodamine and Its Application in Cell Imaging

    Directory of Open Access Journals (Sweden)

    Chunwei Yu

    2014-11-01

    Full Text Available A new fluorescent probe P based on rhodamine for Cu2+ was synthesized and characterized. The new probe P showed high selectivity to Cu2+ over other tested metal ions. With optimal conditions, the proposed probe P worked in a wide linear range of 1.0 × 10−6–1.0 × 10−5 M with a detection limit of 3.3 × 10−7 M Cu2+ in ethanol-water solution (9:1, v:v, 20 mM HEPES, pH 7.0. Furthermore, it has been used for imaging of Cu2+ in living cells with satisfying results.

  6. Design and construction of high-frequency magnetic probe system on the HL-2A tokamak

    Science.gov (United States)

    Liang, S. Y.; Ji, X. Q.; Sun, T. F.; Xu, Yuan; Lu, J.; Yuan, B. S.; Ren, L. L.; Yang, Q. W.

    2017-12-01

    A high-frequency magnetic probe system is designed, calibrated and constructed on the HL-2A tokamak. To investigate the factors which affect the probe frequency response, the inductance and capacitance in the probe system are analyzed using an equivalent circuit. Suitable sizes and turn number of the coil, and the length of transmission cable are optimized based on the theory and detailed test in the calibration. To deal with the frequency response limitation and bake-out, the ceramic grooved technique is used and the probe is wound with a bare copper wire. A cascade filter is manufactured with a suitable bandwidth as well as a good phase consistency between channels. The system has been used in the experiment to measure high frequency (≤300 kHz) magnetohydrodynamic fluctuations, which can meet the requirement of physical analysis on HL-2A.

  7. Preparation of a Two-Photon Fluorescent Probe for Imaging H2O2 in Lysosomes in Living Cells and Tissues.

    Science.gov (United States)

    Ren, Mingguang; Deng, Beibei; Kong, Xiuqi; Tang, Yonghe; Lin, Weiying

    2017-01-01

    Hydrogen peroxide (H 2 O 2 ) plays important roles in many physiological and pathological processes. At the cellular organelle level, the abnormal concentrations of H 2 O 2 in the lysosomes may cause redox imbalance and the loss of the critical functions of the lysosomes. Herein, we describe the preparation of a potent lysosome-targeted two-photon fluorescent probe (Lyso-HP) for the detection of H 2 O 2 in the lysosomes in the living cells. This unique fluorescent probe can also be employed to effectively detect H 2 O 2 in the living tissues using two-photon fluorescence microscopy.

  8. FY1995 development of a endoscopic surgical system utilizing multi-modal functional images; 1995 nendo tashu kino gazo wo mochiiru teishinshu naishikyo shujutsu system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    The purpose of this study is to develop an endoscope system for neurosurgery that can provide not only conventional endoscopic images but also ultraviolet-visible spectra, fluorescence spectra, near infrared spectra, and ultra-soundimages of tissue aiming for real-time identification of pathological tissue. The system also incorporates surgical manipulator and devices such as micro forceps and laser surgical instruments for endoscopic image guided surgery. Surgical Manipulator should be a high performance and easy to operate surgical instrument as well as conventional surgical tools such as scissors and knife. Since living tissue deforms during surgical operation, pre-operative three dimensional information for registration of pathological tissue should be modified based on information obtained during surgery. Thus surgical manipulator should be operated under guidance of surgeon's observation. Consequently, surgical manipulator should have various types of imaging and measurement devices such as an endoscope and an ultrasound imaging probe at its end effectors. Based on this concept, a prototype of a new multi channel surgical manipulator system CM cube (CM3, Computer aided Micro Multichannel Manipulator) that has various types of imaging and measurement devices such as ultra-violet-visible camera for spectroscopic measurement, ultra-sound imaging probe, three dimensional endoscope, together with micro surgical instruments and laser surgical systems has been developed. Its performance was evaluated through in vitro/in vivo experiments and clinical application. (NEDO)

  9. MnO2 nanosheet mediated "DD-A" FRET binary probes for sensitive detection of intracellular mRNA.

    Science.gov (United States)

    Ou, Min; Huang, Jin; Yang, Xiaohai; Quan, Ke; Yang, Yanjing; Xie, Nuli; Wang, Kemin

    2017-01-01

    The donor donor-acceptor (DD-A) FRET model has proven to have a higher FRET efficiency than donor-acceptor acceptor (D-AA), donor-acceptor (D-A), and donor donor-acceptor acceptor (DD-AA) FRET models. The in-tube and in-cell experiments clearly demonstrate that the "DD-A" FRET binary probes can indeed increase the FRET efficiency and provide higher imaging contrast, which is about one order of magnitude higher than the ordinary "D-A" model. Furthermore, MnO 2 nanosheets were employed to deliver these probes into living cells for intracellular TK1 mRNA detection because they can adsorb ssDNA probes, penetrate across the cell membrane and be reduced to Mn 2+ ions by intracellular GSH. The results indicated that the MnO 2 nanosheet mediated "DD-A" FRET binary probes are capable of sensitive and selective sensing gene expression and chemical-stimuli changes in gene expression levels in cancer cells. We believe that the MnO 2 nanosheet mediated "DD-A" FRET binary probes have the potential as a simple but powerful tool for basic research and clinical diagnosis.

  10. Surgical management of esophageal achalasia: Evolution of an institutional approach to minimally invasive repair.

    Science.gov (United States)

    Petrosyan, Mikael; Khalafallah, Adham M; Guzzetta, Phillip C; Sandler, Anthony D; Darbari, Anil; Kane, Timothy D

    2016-10-01

    Surgical management of esophageal achalasia (EA) in children has transitioned over the past 2 decades to predominantly involve laparoscopic Heller myotomy (LHM) or minimally invasive surgery (MIS). More recently, peroral endoscopic myotomy (POEM) has been utilized to treat achalasia in children. Since the overall experience with surgical management of EA is contingent upon disease incidence and surgeon experience, the aim of this study is to report a single institutional contemporary experience for outcomes of surgical treatment of EA by LHM and POEM, with regards to other comparable series in children. An IRB approved retrospective review of all patients with EA who underwent treatment by a surgical approach at a tertiary US children's hospital from 2006 to 2015. Data including demographics, operative approach, Eckardt scores pre- and postoperatively, complications, outcomes, and follow-up were analyzed. A total of 33 patients underwent 35 operative procedures to treat achalasia. Of these operations; 25 patients underwent laparoscopic Heller myotomy (LHM) with Dor fundoplication; 4 patients underwent LHM alone; 2 patients underwent LHM with Thal fundoplication; 2 patients underwent primary POEM; 2 patients who had had LHM with Dor fundoplication underwent redo LHM with takedown of Dor fundoplication. Intraoperative complications included 2 mucosal perforations (6%), 1 aspiration, 1 pneumothorax (1 POEM patient). Follow ranged from 8months to 7years (8-84months). There were no deaths and no conversions to open operations. Five patients required intervention after surgical treatment of achalasia for recurrent dysphagia including 3 who underwent between 1 and 3 pneumatic dilations; and 2 who had redo LHM with takedown of Dor fundoplication with all patients achieving complete resolution of symptoms. Esophageal achalasia in children occurs at a much lower incidence than in adults as documented by published series describing the surgical treatment in children. We

  11. Dynamics of exciton relaxation in LH2 antenna probed by multipulse nonlinear spectroscopy.

    Science.gov (United States)

    Novoderezhkin, Vladimir I; Cohen Stuart, Thomas A; van Grondelle, Rienk

    2011-04-28

    We explain the relaxation dynamics in the LH2-B850 antenna as revealed by multipulse pump-dump-probe spectroscopy (Th. A. Cohen Stuart, M. Vengris, V. I. Novoderezhkin, R. J. Cogdell, C. N. Hunter, R. van Grondelle, submitted). The theory of pump-dump-probe response is evaluated using the doorway-window approach in combination with the modified Redfield theory. We demonstrate that a simultaneous fit of linear spectra, pump-probe, and pump-dump-probe kinetics can be obtained at a quantitative level using the disordered exciton model, which is essentially the same as used to model the spectral fluctuations in single LH2 complexes (Novoderezhkin, V.; Rutkauskas, D.; van Grondelle, R. Biophys. J. 2006, 90, 2890). The present studies suggest that the observed relaxation rates are strongly dependent on the realization of the disorder. A big spread of the rates (exceeding 3 orders of magnitude) is correlated with the disorder-induced changes in delocalization length and overlap of the exciton wave functions. We conclude that the bulk kinetics reflect a superposition of many pathways corresponding to different physical limits of energy transfer, varying from sub-20 fs relaxation between delocalized and highly spatially overlapping exciton states to >20 ps jumps between states localized at the opposite sides of the ring.

  12. A low molecular weight zinc2+-dipicolylamine-based probe detects apoptosis during tumour treatment better than an annexin V-based probe

    International Nuclear Information System (INIS)

    Palmowski, Karin; Rix, Anne; Lederle, Wiltrud; Kiessling, Fabian; Behrendt, Florian F.; Mottaghy, Felix M.; Gray, Brian D.; Pak, Koon Y.; Palmowski, Moritz

    2014-01-01

    Molecular imaging of apoptosis is frequently discussed for monitoring cancer therapies. Here, we compare the low molecular weight phosphatidylserine-targeting ligand zinc 2+ -dipicolylamine (Zn 2+ -DPA) with the established but reasonably larger protein annexin V. Molecular apoptosis imaging with the fluorescently labelled probes annexin V (750 nm, 36 kDa) and Zn 2+ -DPA (794 nm, 1.84 kDa) was performed in tumour-bearing mice (A431). Three animal groups were investigated: untreated controls and treated tumours after 1 or 4 days of anti-angiogenic therapy (SU11248). Additionally, μPET with 18 F-FDG was performed. Imaging data were displayed as tumour-to-muscle ratio (TMR) and validated by quantitative immunohistochemistry. Compared with untreated control tumours, TUNEL staining indicated significant apoptosis after 1 day (P 2+ -DPA uptake increased significantly after 1 day (P 2+ -DPA, 18 F-FDG tumour uptake decreased significantly at days 1 (P 2+ -DPA than with the annexin V-based probe. Additionally, significant treatment effects were detectable as early using Zn 2+ -DPA as with measurements of the glucose metabolism using 18 F-FDG. (orig.)

  13. A study on the growth of compound semiconductor single crystal by TOM technique

    International Nuclear Information System (INIS)

    Kim, H.C.; Kwon, S.I.; Chung, M.K.; Chang, J.S.

    1981-01-01

    This paper describes the merit of the HgI 2 single crystals obtained by solution growth, 2- and 3-region temperature growth, and temperature oscillation growth for soft γ-ray detectors which can be operated at room temperature. Special efforts are put on the design, construction, and operation of the TOM (Temperature Oscillation Method) single crystal growing furnace. Experimental results show that HgI 2 detectors fabricated by vapour phase growth method usually exhibit sufficient enough detector characteristics for soft γ-ray spectrometry. However, further investigation should be carried out to eliminate detector deterioration due to polarization effect. (author)

  14. Development of ion diagnostic system based on electrostatic probe in the boundary plasma of the JFT-2M tokamak

    International Nuclear Information System (INIS)

    Uehara, Kazuya; Kawakami, Tomohide; Amemiya, Hiroshi; Hoethker, K.; Cosler, A.; Bieger, W.

    1995-06-01

    An ion diagnostic system using electrostatic probes for measurements in the JFT-2M tokamak boundary plasma has been developed under the collaboration program between KFA and JAERI. The rotating double probe system, on which the Hoethker double probe and Amemiya asymmetric probe can mounted, are manufactured at KFA workshop while the linear driver to support the rotating double probe, the ion toothbrush probe, the Katsumata probe and the cubic Mach probe are developed at JAERI. This report describes the hardware of this probe system for ion diagnostics in the boundary plasma and preliminary data obtained by means of this system. Furthermore, results on the transport are estimated on the basis of these probe data. (author)

  15. Establishment of a novel immunoassay system for rapid detection of 2,4-dichlorophenoxyacetic acid residues based on magnetic-fluorescent probes

    Directory of Open Access Journals (Sweden)

    WANG Yuanfeng

    2014-12-01

    Full Text Available A novel immunoassay system based on magnetic-fluorescent probes was established to detect 2.4-dichlorophenoxyacetic acid (2,4-D residue in liquid system in food and agricultural products.The composites of anti-2,4-D antibody bound to Fe3O4@SiO2-NH2 was employed as the solid phase as well as magnetic probe.The composites composed of 2,4-D-OVA labeled with CdTe@SiO2-NH2 as the fluorescent probe was used to produce fluorescent signal.2,4-D and its fluorescent probe competed binding the antibody on the surface of the magnetic probe.The optimization of 2,4-D-OVA dosage,coupling PH and reaction time in preparing the fluorescent probe were investigated.It showed that in the synthesis of fluorescent probe 8.2 was the optimal pH,70 min was the optimal coupling time,500 μL amount of 2,4-D-OVA.The standard curve was obtained with the concentration of 2,4-D and the maximum fluorescence intensity.The detection limit of the assay was gotten and it was 3.55×10-8.One reaction step and one washing step were needed.The assay significantly shortened the testing time and amplified the detection signal compared with classic ELISA.

  16. A low glycemic index diet does not affect postprandial energy metabolism but decreases postprandial insulinemia and increases fullness ratings in healthy women

    DEFF Research Database (Denmark)

    Krog-Mikkelsen, Inger; Sloth, Birgitte; Dimitrov, Dimiter

    2011-01-01

    At present, it is difficult to determine whether glycemic index (GI) is an important tool in the prevention of lifestyle diseases, and long-term studies investigating GI with diets matched in macronutrient composition, fiber content, energy content, and energy density are still scarce. We...... investigated the effects of 2 high-carbohydrate (55%) diets with low GI (LGI; 79) or high GI (HGI; 103) on postprandial blood profile, subjective appetite sensations, energy expenditure (EE), substrate oxidation rates, and ad libitum energy intake (EI) from a corresponding test meal (LGI or HGI) after...... composition, fiber content, and energy density. The LGI meal resulted in lower plasma glucose, serum insulin, and plasma glucagon-like peptide (GLP)-1 and higher plasma glucose-dependent insulinotropic polypeptide concentrations than the HGI meal (P ≤ 0.05). Ratings of fullness were slightly higher...

  17. Use of gamma probe in 131I thyroid uptake studies

    International Nuclear Information System (INIS)

    Sarmento, Andrea Gondim Leitao

    2002-11-01

    Evaluation of thyroid uptake by administration of radioactive iodine is a well-defined procedure to assess patient thyroid function. In general, nuclear medicine institutions use gamma cameras coupled to pinhole collimators to perform uptake studies. With the growing use of intraoperative gamma probes in the radioguided surgical techniques, several institutions are purchasing this new and portable equipment, which can technically be also employed to assess patient's thyroid function, permitting further other applications of gamma cameras. The aim of the study was to compare thyroid uptake trails carried out with both gamma camera and intraoperative gamma probe, in order to evaluate the possible use of gamma probe for this purpose. At first a preliminary study of feasibility was carried out using a neck phantom to verify equipment efficiency with known activities of 131 I. Henceforth, work data from 12 patients undergone studies of thyroid uptakes were evaluated, 24 hours after oral administration of 370 kBq of 131 I. The maximum difference observed between the values obtained with both equipment was 60%, which demonstrated the feasibility of the proposed protocol and made clear that gamma probe can be useful for thyroid uptake studies. (author)

  18. Effects of Frequent Glove Change on Outcomes of Orthopaedic Surgical Procedures - A Multicenter Study on Surgical Gloves

    Directory of Open Access Journals (Sweden)

    Nishit Palo

    2017-10-01

    Full Text Available Introduction: Intact surgical gloves are a barrier to microorganisms migration between surgical team members and the patient. The surgical gloves are changed at various junctures but the effects of changing gloves during surgical procedures on various surgical parameters or clinical outcomes are not established. Aim: To determine rationale of glove change during orthopaedic procedures, differences amongst surgical parameters with and without changing the surgical gloves and whether frequent glove change affected surgical parameters or clinical outcomes. Materials and Methods: A prospective multicenter study conducted at three centers from January 2014 to January 2016. A 250 patients were divided into 2 groups (n=125 each in Group 1, surgical team operated with regular changing of gloves. In Group 2, only 1 set of double gloves were worn throughout the procedure. Surgical parameters or clinical outcomes were assessed for both the groups. Statistical analyses included the median, mode, range, Interquartile Range (IQR and sample standard deviation (s and independent-samples t-test. Bacterial counts were expressed as median with (IQR. Results: Surgical Timing Difference was 10 (S.D.- 4.2 minutes more in Group-1 (<0.05, Surgical Cost was higher in Group-1 by Rs.150-450 (<0.05. Outer glove micro-perforation rate was 5.85% and 8.15% in group-1 and 2 respectively with no inner glove perforation or Surgical Site Infections. Outer glove micro perforations were proportional to duration of surgery; operations lasting 120-210 and 61-120 minutes had 66.6% and 37.2% micro perforation rates respectively (p<0.05. Conclusion: Under standard operating conditions, procedures performed without glove change are shorter and cost effective than procedures performed with regular glove change with similar surgical and functional results. Judicious use of surgical gloves is a patient and environment friendly option, thereby reducing the hospital’s biomedical waste load.

  19. A low molecular weight zinc{sup 2+}-dipicolylamine-based probe detects apoptosis during tumour treatment better than an annexin V-based probe

    Energy Technology Data Exchange (ETDEWEB)

    Palmowski, Karin [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); University of Heidelberg, Department of Pneumology, Thoraxklinik Heidelberg, Heidelberg (Germany); Rix, Anne; Lederle, Wiltrud; Kiessling, Fabian [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); Behrendt, Florian F. [RWTH-Aachen University, Department of Nuclear Medicine, Aachen (Germany); Mottaghy, Felix M. [RWTH-Aachen University, Department of Nuclear Medicine, Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, Maastricht (Netherlands); Gray, Brian D. [Molecular Targeting Technologies, Inc., West Chester, PA (United States); Pak, Koon Y. [University Medical Center Heidelberg, Academic Radiology Baden-Baden, Diagnostic and Interventional Radiology, Heidelberg (Germany); Palmowski, Moritz [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); RWTH-Aachen University, Department of Nuclear Medicine, Aachen (Germany); University Medical Center Heidelberg, Academic Radiology Baden-Baden, Diagnostic and Interventional Radiology, Heidelberg (Germany)

    2014-02-15

    Molecular imaging of apoptosis is frequently discussed for monitoring cancer therapies. Here, we compare the low molecular weight phosphatidylserine-targeting ligand zinc{sup 2+}-dipicolylamine (Zn{sup 2+}-DPA) with the established but reasonably larger protein annexin V. Molecular apoptosis imaging with the fluorescently labelled probes annexin V (750 nm, 36 kDa) and Zn{sup 2+}-DPA (794 nm, 1.84 kDa) was performed in tumour-bearing mice (A431). Three animal groups were investigated: untreated controls and treated tumours after 1 or 4 days of anti-angiogenic therapy (SU11248). Additionally, μPET with {sup 18} F-FDG was performed. Imaging data were displayed as tumour-to-muscle ratio (TMR) and validated by quantitative immunohistochemistry. Compared with untreated control tumours, TUNEL staining indicated significant apoptosis after 1 day (P < 0.05) and 4 days (P < 0.01) of treatment. Concordantly, Zn{sup 2+}-DPA uptake increased significantly after 1 day (P < 0.05) and 4 days (P < 0.01). Surprisingly, annexin V failed to detect significant differences between control and treated animals. Contrary to the increasing uptake of Zn{sup 2+}-DPA, {sup 18} F-FDG tumour uptake decreased significantly at days 1 (P < 0.05) and 4 (P < 0.01). Increase in apoptosis during anti-angiogenic therapy was detected significantly better with the low molecular weight probe Zn{sup 2+}-DPA than with the annexin V-based probe. Additionally, significant treatment effects were detectable as early using Zn{sup 2+}-DPA as with measurements of the glucose metabolism using {sup 18} F-FDG. (orig.)

  20. A subnanomolar fluorescent probe for protein kinase CK2 interaction studies

    DEFF Research Database (Denmark)

    Enkvist, Erki; Viht, Kaido; Bischoff, Nils

    2012-01-01

    of the functions of CK2 could be facilitated by the application of small-molecule fluorescent probes that bind to the active site of the enzyme with high affinity and selectivity. We have used a bisubstrate approach for the development of a highly potent inhibitor of CK2. 4,5,6,7-Tetrabromo-1H-benzimidazole...

  1. Automatic localization of the da Vinci surgical instrument tips in 3-D transrectal ultrasound.

    Science.gov (United States)

    Mohareri, Omid; Ramezani, Mahdi; Adebar, Troy K; Abolmaesumi, Purang; Salcudean, Septimiu E

    2013-09-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical system is the current state-of-the-art treatment option for clinically confined prostate cancer. Given the limited field of view of the surgical site in RALRP, several groups have proposed the integration of transrectal ultrasound (TRUS) imaging in the surgical workflow to assist with accurate resection of the prostate and the sparing of the neurovascular bundles (NVBs). We previously introduced a robotic TRUS manipulator and a method for automatically tracking da Vinci surgical instruments with the TRUS imaging plane, in order to facilitate the integration of intraoperative TRUS in RALRP. Rapid and automatic registration of the kinematic frames of the da Vinci surgical system and the robotic TRUS probe manipulator is a critical component of the instrument tracking system. In this paper, we propose a fully automatic registration technique based on automatic 3-D TRUS localization of robot instrument tips pressed against the air-tissue boundary anterior to the prostate. The detection approach uses a multiscale filtering technique to identify and localize surgical instrument tips in the TRUS volume, and could also be used to detect other surface fiducials in 3-D ultrasound. Experiments have been performed using a tissue phantom and two ex vivo tissue samples to show the feasibility of the proposed methods. Also, an initial in vivo evaluation of the system has been carried out on a live anaesthetized dog with a da Vinci Si surgical system and a target registration error (defined as the root mean square distance of corresponding points after registration) of 2.68 mm has been achieved. Results show this method's accuracy and consistency for automatic registration of TRUS images to the da Vinci surgical system.

  2. 2-cm versus 4-cm surgical excision margins for primary cutaneous melanoma thicker than 2 mm: a randomised, multicentre trial

    DEFF Research Database (Denmark)

    Gillgren, Peter; Drzewiecki, Krzysztof T; Niin, Marianne

    2011-01-01

    Optimum surgical resection margins for patients with clinical stage IIA-C cutaneous melanoma thicker than 2 mm are controversial. The aim of the study was to test whether survival was different for a wide local excision margin of 2 cm compared with a 4-cm excision margin.......Optimum surgical resection margins for patients with clinical stage IIA-C cutaneous melanoma thicker than 2 mm are controversial. The aim of the study was to test whether survival was different for a wide local excision margin of 2 cm compared with a 4-cm excision margin....

  3. Associação de Rhizoctonia solani Grupo de Anastomose 4 (AG-4 HGI e HGIII à espécies de plantas invasoras de área de cultivo de batata Rhizoctonia solani anastomosis group 4 (AG-4 HGI and HGIII associated with weed species from a potato cropping area

    Directory of Open Access Journals (Sweden)

    Fátima Aparecida da Silva-Barreto

    2010-06-01

    Full Text Available Os grupos 3 e 4 de anastomose (AG-3 e AG-4 do fungo Rhizoctonia solani são importantes grupos associados à batata no mundo. No Brasil, o AG-3 é relatado afetando principalmente batata e fumo. Já o AG-4 causa perdas consideráveis em culturas de importância econômica, como a soja, o feijão e o amendoim, podendo ocorrer também em hortaliças como o espinafre, o pimentão, o brócolis, o tomate, a batata e frutíferas como o melão. Recentemente foi constatada, em Brasília-DF, a associação de R. solani a plantas invasoras em áreas de cultivo de batata. Entretanto, não há informação a respeito da etiologia do patógeno bem como do papel de espécies invasoras como outras hospedeiras no ciclo do patógeno. Objetivou-se com esse estudo caracterizar isolados de R. solani obtidos de batata e de outras três espécies de plantas invasoras associadas a áreas de cultivo da cultura: juá-de-capote [Nicandra physaloides (L. Pers., Solanaceae], beldroega (Portulaca oleracea L., Portulacaceae, e caruru (Amaranthus deflexus L., Amaranthaceae. Foi confirmada a hipótese de que os isolados obtidos de R. solani de beldroega, caruru e juá-de-capote pertencem ao grupo 4 de anastomose e são patogênicos à batata, exceto o isolado de beldroega. Estes isolados apresentaram patogenicidade cruzada às três espécies e também patogênicos à maria-pretinha (Solanum americanum Mill., uma outra espécie de Solanaceae invasora. A classificação dos isolados no grupo AG-4 HGI ou no grupo AG-4 HGIII (isolado de caruru foi confirmada através de características culturais e moleculares (seqüenciamento da região ITS-5.8S do rDNA. Os resultados deste trabalho trazem implicações importantes para o manejo das podridões radiculares de Rhizoctonia em batata.The anastomosis groups 3 and 4 (AG-3 and AG-4 of the fungus Rhizoctonia solani are important groups associated with potatoes worldwide. In Brazil, the AG-3 is reported affecting mainly potatoes and

  4. Design of mitochondria-targeted colorimetric and ratiometric fluorescent probes for rapid detection of SO2 derivatives in living cells

    Science.gov (United States)

    Yang, Yutao; Zhou, Tingting; Bai, Bozan; Yin, Caixia; Xu, Wenzhi; Li, Wei

    2018-05-01

    Two mitochondria-targeted colorimetric and ratiometric fluorescent probes for SO2 derivatives were constructed based on the SO2 derivatives-triggered Michael addition reaction. The probes exhibit high specificity toward HSO3-/SO32- by interrupting their conjugation system resulting in a large ratiometric blue shift of 46-121 nm in their emission spectrum. The two well-resolved emission bands can ensure accurate detection of HSO3-. The detection limits were calculated to be 1.09 and 1.35 μM. Importantly, probe 1 and probe 2 were successfully used to fluorescence ratiometric imaging of endogenous HSO3- in BT-474 cells.

  5. Modular Rake of Pitot Probes

    Science.gov (United States)

    Dunlap, Timothy A.; Henry, Michael W.; Homyk, Raymond P.

    2004-01-01

    The figure presents selected views of a modular rake of 17 pitot probes for measuring both transient and steady-state pressures in a supersonic wind tunnel. In addition to pitot tubes visible in the figure, the probe modules contain (1) high-frequency dynamic-pressure transducers connected through wires to remote monitoring circuitry and (2) flow passages that lead to tubes that, in turn, lead to remote steady-state pressure transducers. Prior pitot-probe rakes were fabricated as unitary structures, into which the individual pitot probes were brazed. Repair or replacement of individual probes was difficult, costly, and time-consuming because (1) it was necessary to remove entire rakes in order to unbraze individual malfunctioning probes and (2) the heat of unbrazing a failed probe and of brazing a new probe in place could damage adjacent probes. In contrast, the modules in the present probe are designed to be relatively quickly and easily replaceable with no heating and, in many cases, without need for removal of the entire rake from the wind tunnel. To remove a malfunctioning probe, one first removes a screw-mounted V-cross-section cover that holds the probe and adjacent probes in place. Then one removes a screw-mounted cover plate to gain access to the steady-state pressure tubes and dynamicpressure wires. Next, one disconnects the tube and wires of the affected probe. Finally, one installs a new probe in the reverse of the aforementioned sequence. The wire connections can be made by soldering, but to facilitate removal and installation, they can be made via miniature plugs and sockets. The connections between the probe flow passages and the tubes leading to the remote pressure sensors can be made by use of any of a variety of readily available flexible tubes that can be easily pulled off and slid back on for removal and installation, respectively.

  6. Characterization of the ER-Targeted Low Affinity Ca2+ Probe D4ER

    Directory of Open Access Journals (Sweden)

    Elisa Greotti

    2016-09-01

    Full Text Available Calcium ion (Ca2+ is a ubiquitous intracellular messenger and changes in its concentration impact on nearly every aspect of cell life. Endoplasmic reticulum (ER represents the major intracellular Ca2+ store and the free Ca2+ concentration ([Ca2+] within its lumen ([Ca2+]ER can reach levels higher than 1 mM. Several genetically-encoded ER-targeted Ca2+ sensors have been developed over the last years. However, most of them are non-ratiometric and, thus, their signal is difficult to calibrate in live cells and is affected by shifts in the focal plane and artifactual movements of the sample. On the other hand, existing ratiometric Ca2+ probes are plagued by different drawbacks, such as a double dissociation constant (Kd for Ca2+, low dynamic range, and an affinity for the cation that is too high for the levels of [Ca2+] in the ER lumen. Here, we report the characterization of a recently generated ER-targeted, Förster resonance energy transfer (FRET-based, Cameleon probe, named D4ER, characterized by suitable Ca2+ affinity and dynamic range for monitoring [Ca2+] variations within the ER. As an example, resting [Ca2+]ER have been evaluated in a known paradigm of altered ER Ca2+ homeostasis, i.e., in cells expressing a mutated form of the familial Alzheimer’s Disease-linked protein Presenilin 2 (PS2. The lower Ca2+ affinity of the D4ER probe, compared to that of the previously generated D1ER, allowed the detection of a conspicuous, more clear-cut, reduction in ER Ca2+ content in cells expressing mutated PS2, compared to controls.

  7. Development and characterization of a handheld hyperspectral Raman imaging probe system for molecular characterization of tissue on mesoscopic scales.

    Science.gov (United States)

    St-Arnaud, Karl; Aubertin, Kelly; Strupler, Mathias; Madore, Wendy-Julie; Grosset, Andrée-Anne; Petrecca, Kevin; Trudel, Dominique; Leblond, Frédéric

    2018-01-01

    Raman spectroscopy is a promising cancer detection technique for surgical guidance applications. It can provide quantitative information relating to global tissue properties associated with structural, metabolic, immunological, and genetic biochemical phenomena in terms of molecular species including amino acids, lipids, proteins, and nucleic acid (DNA). To date in vivo Raman spectroscopy systems mostly included probes and biopsy needles typically limited to single-point tissue interrogation over a scale between 100 and 500 microns. The development of wider field handheld systems could improve tumor localization for a range of open surgery applications including brain, ovarian, and skin cancers. Here we present a novel Raman spectroscopy implementation using a coherent imaging bundle of fibers to create a probe capable of reconstructing molecular images over mesoscopic fields of view. Detection is performed using linear scanning with a rotation mirror and an imaging spectrometer. Different slits widths were tested at the entrance of the spectrometer to optimize spatial and spectral resolution while preserving sufficient signal-to-noise ratios to detect the principal Raman tissue features. The nonbiological samples, calcite and polytetrafluoroethylene (PTFE), were used to characterize the performance of the system. The new wide-field probe was tested on ex vivo samples of calf brain and swine tissue. Raman spectral content of both tissue types were validated with data from the literature and compared with data acquired with a single-point Raman spectroscopy probe. The single-point probe was used as the gold standard against which the new instrument was benchmarked as it has already been thoroughly validated for biological tissue characterization. We have developed and characterized a practical noncontact handheld Raman imager providing tissue information at a spatial resolution of 115 microns over a field of view >14 mm 2 and a spectral resolution of 6 cm -1 over

  8. A new rhodamine-based fluorescent probe for the discrimination of Fe{sup 3+} from Fe{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    You, Qi Hua; Huang, Hua Bin; Zhuang, Zhi Xia; Wang, Xiao Ru [Dept. of Science and Technology for Inspection, Xiamen Huaxia University, Xiamen (China); Chan, Wing Hong [Dept. of of Chemistry, Hong Kong Bap tist University, Hong Kong (China)

    2016-11-15

    A new rhodamine-based fluorescent probe for the discrimination of Fe{sup 3+} from Fe{sup 2+} has been designed and investigated. The probe shows an immediate visual color change in response to Fe{sup 3+} and Cu{sup 2+}, while only Fe{sup 3+} triggers the fluorescent change of the probe. The existence of large amount of other metal ions shows negligible interference in the detection of Fe{sup 3+}. The association constant K{sub ass} of 4.64 × 10{sup 8} M{sup -2} (R{sup 2} = 0.994) and 5.38 × 10{sup 8} M{sup -2} (R{sup 2} = 0.991) of the complex was derived from UV/Vis and fluorescence titration assuming 1:2 stoichiometry of probe–Fe{sup 3+} complex, respectively.

  9. [Comparative effectiveness of surgical and non-surgical treatment for pediatric mandibular condylar fractures].

    Science.gov (United States)

    Hu, Min; Wang, Yanyi; Zhang, Lihai; Yao, Jun

    2010-12-01

    To compare the effectiveness of open reduction and conservative treatment for pediatric mandibular condylar fractures and to provide the evidence for the selection of clinical therapy. The clinical data were retrospectively analyzed from 25 patients with the mandibular condylar fractures between January 1988 and December 2006. Of them, 8 patients (11 fractures) were treated with surgical treatment (surgical group) and 17 patients (22 fractures) with non-surgical treatment (non-surgical group). In surgical group, there were 6 males (9 fractures) and 2 females (2 fractures) with an age range of 8-13 years; fracture was caused by tumbling in 7 cases and by traffic accident in 1 with an interval of 1-6 days between injury and hospitalization; and 5 cases were identified as unilateral condylar fractures (3 complicated by mental fractures) and 3 cases as bilateral condylar fractures complicated by mental fractures. In non-surgical group, there were 12 males (15 fractures) and 5 females (7 fractures) with an age range of 3-12 years; fracture was caused by falling from height in 4 cases, by tumbling in 10, and by traffic accident in 3 with an interval of 1-25 days between injury and hospitalization; and 12 cases were identified as unilateral condylar fractures (3 complicated by mental fractures) and 5 cases as bilateral condylar fractures (1 complicated by mental fracture). Incision healed by first intention in surgical group, and 25 cases were followed up 1-6 years with an average of 3.5 years. At 12 months after treatment, no temporomandibular joint pain, eating disorder, or limited mandibular movement occurred in 2 groups. No significant difference was observed in opening mouth extent, protrusive and lateral movements between 2 groups at 6 and 12 months (P > 0.05). During centric occlusion, mental point located at the midline with symmetric face figure. Two patients in surgical group and 3 in non-surgical group had slight snap when opening their mouths. Mandible

  10. Effect of Incremental Endoscopic Maxillectomy on Surgical Exposure of the Pterygopalatine and Infratemporal Fossae.

    Science.gov (United States)

    Upadhyay, Smita; Dolci, Ricardo L L; Buohliqah, Lamia; Fiore, Mariano E; Ditzel Filho, Leo F S; Prevedello, Daniel M; Otto, Bradley A; Carrau, Ricardo L

    2016-02-01

    Objective Access to the pterygopalatine and infratemporal fossae presents a significant surgical challenge, owing to their deep-seated location and complex neurovascular anatomy. This study elucidates the benefits of incremental medial maxillectomies to access this region. We compared access to the medial aspect of the infratemporal fossa provided by medial maxillectomy, anteriorly extended medial maxillectomy, endoscopic Denker approach (i.e., Sturmann-Canfield approach), contralateral transseptal approach, and the sublabial anterior maxillotomy (SAM). Methods We studied 10 cadaveric specimens (20 sides) dissecting the pterygopalatine and infratemporal fossae bilaterally. Radius of access was calculated using a navigation probe aligned with the endoscopic line of sight. Area of exposure was calculated as the area removed from the posterior wall of maxillary sinus. Surgical freedom was calculated by computing the working area at the proximal end of the instrument with the distal end fixed at a target. Results The endoscopic Denker approach offered a superior area of exposure (8.46 ± 1.56 cm(2)) and superior surgical freedom. Degree of lateral access with the SAM approach was similar to that of the Denker. Conclusion Our study suggests that an anterior extension of the medial maxillectomy or a cross-court approach increases both the area of exposure and surgical freedom. Further increases can be seen upon progression to a Denker approach.

  11. DNA probes

    Energy Technology Data Exchange (ETDEWEB)

    Castelino, J

    1993-12-31

    The creation of DNA probes for detection of specific nucleotide segments differs from ligand detection in that it is a chemical rather than an immunological reaction. Complementary DNA or RNA is used in place of the antibody and is labelled with {sup 32}P. So far, DNA probes have been successfully employed in the diagnosis of inherited disorders, infectious diseases, and for identification of human oncogenes. The latest approach to the diagnosis of communicable and parasitic infections is based on the use of deoxyribonucleic acid (DNA) probes. The genetic information of all cells is encoded by DNA and DNA probe approach to identification of pathogens is unique because the focus of the method is the nucleic acid content of the organism rather than the products that the nucleic acid encodes. Since every properly classified species has some unique nucleotide sequences that distinguish it from every other species, each organism`s genetic composition is in essence a finger print that can be used for its identification. In addition to this specificity, DNA probes offer other advantages in that pathogens may be identified directly in clinical specimens 10 figs, 2 tabs

  12. Comparison of appetite responses to high- and low-glycemic index postexercise meals under matched insulinemia and fiber in type 1 diabetes.

    Science.gov (United States)

    Campbell, Matthew D; Gonzalez, Javier T; Rumbold, Penny L S; Walker, Mark; Shaw, James A; Stevenson, Emma J; West, Daniel J

    2015-03-01

    Patients with type 1 diabetes face heightened risk of hypoglycemia after exercise. Subsequent overfeeding, as a preventative measure against hypoglycemia, negates the energy deficit after exercise. Patients are also required to reduce the insulin dose administered with postexercise foods to further combat hypoglycemia. However, the insulin dose is dictated solely by the carbohydrate content, even though postprandial glycemia is vastly influenced by glycemic index (GI). With a need to control the postexercise energy balance, appetite responses after meals differing in GI are of particular interest. We assessed the appetite response to low-glycemic index (LGI) and high-glycemic index (HGI) postexercise meals in type 1 diabetes patients. This assessment also offered us the opportunity to evaluate the influence of GI on appetite responses independently of insulinemia, which confounds findings in individuals without diabetes. Ten physically active men with type 1 diabetes completed 2 trials in a randomized crossover design. After 45 min of treadmill exercise at 70% of the peak oxygen uptake, participants consumed an LGI (GI ∼37) or HGI (GI ∼92) meal with a matched macronutrient composition, negligible fiber content, and standardized insulin-dose administration. The postprandial appetite response was determined for 180 min postmeal. During this time, circulating glucose, insulin, glucagon, and glucagon-like peptide-1 (GLP-1) concentrations and subjective appetite ratings were determined. The HGI meal produced an ∼60% greater postprandial glucose area under the curve (AUC) than did the LGI meal (P = 0.008). Insulin, glucagon, and GLP-1 did not significantly differ between trials (P > 0.05). The fullness AUC was ∼25% greater after the HGI meal than after the LGI meal (P < 0.001), whereas hunger sensations were ∼9% lower after the HGI meal than after the LGI meal (P = 0.001). Under conditions of matched insulinemia and fiber, an HGI postexercise meal suppresses

  13. Assessment of Periodontal Status of Surgically Exposed and Orthodontically Aligned Impacted Maxillary Canines

    Directory of Open Access Journals (Sweden)

    Adina Coșarcă

    2014-02-01

    Full Text Available Aim: The aim of this study was to compare the periodontal status of impacted canines after 5 years following completion of the combined surgical and orthodontic treatment. Materials and methods: We examined 20 labially impacted canines and 20 palatally impacted canines at 5 years after the end of treatment. We assessed the periodontal status of these teeth. Results: Different outcomes were found regarding the probing depth and the amount of keratinized gingiva in the two mentioned groups of teeth. Conclusions: The assessed periodontal indices may signal the appearance of a periodontal disease around the teeth that were surgically and orthodontically treated

  14. Advantages of CO2 laser use in surgical management of otosclerosis

    Directory of Open Access Journals (Sweden)

    Matković Svjetlana

    2003-01-01

    Full Text Available Background. Otosclerosis is a progressive osteo-destructive disorder of the bony labyrinth in which the fixation of the stapes causes the hearing loss. The aim of this study was the postoperative determination of parameters of the effect of surgical intervention on hearing and the incidence of complications and, on the basis of the differences in the examined parameters of the study, the estimation of the eficacy of the two mentioned surgical thechniques in the treatment of otosclerosis. Methods. In our research 40 patients with conductive hearing loss caused by otosclerosis underwent surgery with CO2 laser. Functional results were compared postoperatively with the results of 40 patients operated by the classical technique without the use of CO2 laser. The research was accomplished as a prospective comparative study. Results. The air-bone interval (gap as the difference between the rim of air and bone conductivity for separate frequencies did not significantly differ between the control and the experimental group. Both methods were effective in closing the air-bone gap with the rates of closure to within 10 dB in 82.6% and 75.3% for the laser and drill, respectively. The incidence of tinnitus was significantly lower in patients who underwent surgery with CO2 laser. The frequency of intraoperative and postoperative complications was significantly lower in the laser group. Differences were statistically significant for all parameters (p<0.05. Conclusion. On the basis of the degree of postoperative hearing improvement, tinnitus and the incidence of complications it can be concluded that the use of CO2 laser during inverse stapedoplasty represents an effective and safe method, justifying the promotion of its use in the surgical management of otosclerosis.

  15. Measurement of cell respiration and oxygenation in standard multichannel biochips using phosphorescent O2-sensitive probes.

    Science.gov (United States)

    Kondrashina, Alina V; Papkovsky, Dmitri B; Dmitriev, Ruslan I

    2013-09-07

    Measurement of cell oxygenation and oxygen consumption is useful for studies of cell bioenergetics, metabolism, mitochondrial function, drug toxicity and common pathophysiological conditions. Here we present a new platform for such applications which uses commercial multichannel biochips (μ-slides, Ibidi) and phosphorescent O2 sensitive probes. This platform was evaluated with both extracellular and intracellular O2 probes, several different cell types and treatments including mitochondrial uncoupling and inhibition, depletion of extracellular Ca(2+) and inhibition of V-ATPase and histone deacetylases. The results show that compared to the standard microwell plates currently used, the μ-slide platform provides facile O2 measurements with both suspension and adherent cells, higher sensitivity and reproducibility, and faster measurement time. It also allows re-perfusion and multiple treatments of cells and multi-parametric analyses in conjunction with other probes. Optical measurements are conducted on standard fluorescence readers and microscopes.

  16. Multifrequency scanning probe microscopy study of nanodiamond agglomerates

    Science.gov (United States)

    Aravind, Vasudeva; Lippold, Stephen; Li, Qian; Strelcov, Evgheny; Okatan, Baris; Legum, Benjamin; Kalinin, Sergei; Clarion University Team; Oak Ridge National Laboratory Team

    Due to their rich surface chemistry and excellent mechanical properties and non-toxic nature, nanodiamond particles have found applications such as biomedicine, tribology and lubrication, targeted drug delivery systems, tissue scaffolds and surgical implants. Although single nanodiamond particles have diameters about 4-5nm, they tend to form agglomerates. While these agglomerates can be useful for some purposes, many applications of nanodiamonds require single particle, disaggregated nanodiamonds. This work is oriented towards studying forces and interactions that contribute to agglomeration in nanodiamonds. In this work, using multifrequency scanning probe microscopy techniques, we show that agglomerate sizes can vary between 50-100nm in raw nanodiamonds. Extremeties of particles and Interfaces between agglomerates show dissipative forces with scanning probe microscope tip, indicating agglomerates could act as points of increased adhesion, thus reducing lubricating efficiency when nanodiamonds are used as lubricant additives. This research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

  17. Metabolic changes after a hypocaloric, low-glycemic-index diet in obese children.

    Science.gov (United States)

    Parillo, M; Licenziati, M R; Vacca, M; De Marco, D; Iannuzzi, A

    2012-07-01

    A low glycemic index (LGI) diet has been proposed as a treatment for obesity in adults; few studies have evaluated LGI diets in obese children. The purpose of the study was to compare the effects of two diets, with similar energy intakes, but different glycemic indexes in a pediatric outpatient setting. A parallel- group, randomized controlled trial was conducted, and 22 obese outpatient children with a body mass index (BMI) Z-score >2 (11 females and 11 males, BMI 28.9±2.9 kg/m²) were included in the study. Patients were randomly allocated to a hypocaloric LGI (GI:60), or to a hypocaloric high glycemic index (HGI) diet (GI:90). The LGI and HGI diets were almost equivalent for macronutrient composition. Anthropometric and biochemical parameters were measured at baseline and after 6 months. In both groups there were significant decreases in BMI, BMI Z-score, blood pressure, and high-sensitivity C-reactive protein. Only LGI diets produced a significant decrease in waist circumference and homeostasis model assessment. Analysis of variance demonstrated that the BMI Z-score decrease from baseline values was significantly greater after the LGI diet than after the HGI diet [-0.20 (95% confidence interval (CI) -0.29 to -0.10) vs -0.34 (95%CI -0.43 to -0.24)], mean difference between groups -0.14 (95%CI -0.27 to -0.01), pdiet (phypocaloric LGI diet has beneficial metabolic effects in comparison to a hypocaloric HGI diet in obese children.

  18. Fabrication of high gradient insulators by stack compression

    Science.gov (United States)

    Harris, John Richardson; Sanders, Dave; Hawkins, Steven Anthony; Norona, Marcelo

    2014-04-29

    Individual layers of a high gradient insulator (HGI) are first pre-cut to their final dimensions. The pre-cut layers are then stacked to form an assembly that is subsequently pressed into an HGI unit with the desired dimension. The individual layers are stacked, and alignment is maintained, using a sacrificial alignment tube that is removed after the stack is hot pressed. The HGI's are used as high voltage vacuum insulators in energy storage and transmission structures or devices, e.g. in particle accelerators and pulsed power systems.

  19. The impact of a low glycaemic index (GI) diet on simultaneous measurements of blood glucose and fat oxidation: A whole body calorimetric study.

    Science.gov (United States)

    Kaur, Bhupinder; Quek Yu Chin, Rina; Camps, Stefan; Henry, Christiani Jeyakumar

    2016-06-01

    Low glycaemic index (GI) foods are known to minimize large fluctuations in blood glucose levels and have been suggested to increase fat oxidation. The objective of this study was to simultaneously investigate glucose excursion and substrate oxidation in a whole body calorimetre when Chinese male subjects were provided a low or high GI meal. In a randomized, controlled crossover non blind design, 12 healthy Chinese male adults (BMI 21.8 ± 1.3 kgm -2 ) attended two sessions consisting of either four low or high glycaemic meals (LGI vs HGI). Breakfast, lunch and snack were consumed in a whole body calorimetre while dinner was consumed at home. Daily changes in glycaemic response (GR) and postprandial GR responses were measured using a continuous glucose monitoring system. The GR was further calculated to obtain the incremental area under the curve (iAUC) for glucose concentrations. Glycaemic variability was calculated as mean amplitude of glycaemic excursion (MAGE). Substrate oxidation was calculated by measuring respiratory quotient and urine nitrogen excretion. After LGI meals in the whole body calorimetre, iAUC for glucose (P = 0.008) was lower compared to the HGI session. The HGI treatment produced a significantly greater MAGE than the LGI treatment over the 24 hour period (P fat oxidation and lower carbohydrate oxidation were observed following breakfast and lunch when comparing LGI to HGI (P fat oxidation over carbohydrate oxidation when compared to HGI mixed meals. The consumption of low GI meals may be a strategic approach in improving overall glycaemia and increasing fat oxidation in Asians consuming a high carbohydrate diet.

  20. Sensitive Phonon-Based Probe for Structure Identification of 1T' MoTe2.

    Science.gov (United States)

    Zhou, Lin; Huang, Shengxi; Tatsumi, Yuki; Wu, Lijun; Guo, Huaihong; Bie, Ya-Qing; Ueno, Keiji; Yang, Teng; Zhu, Yimei; Kong, Jing; Saito, Riichiro; Dresselhaus, Mildred

    2017-06-28

    In this work, by combining transmission electron microscopy and polarized Raman spectroscopy for the 1T' MoTe 2 flakes with different thicknesses, we found that the polarization dependence of Raman intensity is given as a function of excitation laser wavelength, phonon symmetry, and phonon frequency, but has weak dependence on the flake thickness from few-layer to multilayer. In addition, the frequency of Raman peaks and the relative Raman intensity are sensitive to flake thickness, which manifests Raman spectroscopy as an effective probe for thickness of 1T' MoTe 2 . Our work demonstrates that polarized Raman spectroscopy is a powerful and nondestructive method to quickly identify the crystal structure and thickness of 1T' MoTe 2 simultaneously, which opens up opportunities for the in situ probe of anisotropic properties and broad applications of this novel material.

  1. Standardization of D2 lymphadenectomy and surgical quality control (KLASS-02-QC): a prospective, observational, multicenter study [NCT01283893

    International Nuclear Information System (INIS)

    Kim, Hyoung-Il; Hur, Hoon; Kim, Youn Nam; Lee, Hyuk-Joon; Kim, Min-Chan; Han, Sang-Uk; Hyung, Woo Jin

    2014-01-01

    Extended systemic lymphadenectomy (D2) is standard procedure for surgical treatment of advanced gastric cancer (AGC) although less extensive lymphadenectomy (D1) can be applied to early gastric cancer. Complete D2 lymphadenectomy is the mandatory procedure for studies that evaluate surgical treatment results of AGC. However, the actual extent of D2 lymphadenectomy varies among surgeons because of a lacking consensus on the anatomical definition of each lymph node station. This study is aimed to develop a consensus for D2 lymphadenectomy and also to qualify surgeons that can perform both laparoscopic and open D2 gastrectomy. This (KLASS-02-QC) is a prospective, observational, multicenter study to qualify the surgeons that will participate in the KLASS-02-RCT, which is a prospective, randomized, clinical trial comparing laparoscopic and open gastrectomy for AGC. Surgeons and reviewers participating in the study will be required to complete a questionnaire detailing their professional experience and specific gastrectomy surgical background/training, and the gastrectomy metrics of their primary hospitals. All surgeons must submit three laparoscopic and three open D2 gastrectomy videos, respectively. Each video will be allocated to five peer reviewers; thus each surgeon’s operations will be assessed by a total of 30 reviews. Based on blinded assessment of unedited videos by experts’ review, a separate review evaluation committee will decide whether or not the evaluated surgeon will participate in the KLASS-02-RCT. The primary outcome measure is each surgeon’s proficiency, as assessed by the reviewers based on evaluation criteria for completeness of D2 lymphadenectomy. We believe that our study for standardization of D2 lymphadenectomy and surgical quality control (KLASS-02-QC) will guarantee successful implementation of the subsequent KLASS-02-RCT study. After making consensus on D2 lymphadenectomy, we developed evaluation criteria for completeness of D2

  2. Probing N=2 superconformal field theories with localization

    Energy Technology Data Exchange (ETDEWEB)

    Fiol, Bartomeu [Departament de Física Fonamental i Institut de Ciències del Cosmos,Universitat de Barcelona,Martí i Franquès 1, 08028 Barcelona, Catalonia (Spain); Garolera, Blai [Escuela de Física, Universidad de Costa Rica,11501-2060 San José (Costa Rica); Torrents, Genís [Departament de Física Fonamental i Institut de Ciències del Cosmos,Universitat de Barcelona,Martí i Franquès 1, 08028 Barcelona, Catalonia (Spain)

    2016-01-27

    We use supersymmetric localization to study probes of four dimensional Lagrangian N=2 superconformal field theories. We first derive a unique equation for the eigenvalue density of these theories. We observe that these theories have a Wigner eigenvalue density precisely when they satisfy a necessary condition for having a holographic dual with a sensible higher-derivative expansion. We then compute in the saddle-point approximation the vacuum expectation value of 1/2-BPS circular Wilson loops, and the two-point functions of these Wilson loops with the Lagrangian density and with the stress-energy tensor. This last computation also provides the corresponding Bremsstrahlung functions and entanglement entropies. As expected, whenever a finite fraction of the matter is in the fundamental representation, the results are drastically different from those of N=4 supersymmetric Yang-Mills theory.

  3. The AMEMIYA probe. Theoretical background

    International Nuclear Information System (INIS)

    Belitz, Hans Joahim; Althausen, Bernhard; Uehara, Kazuya; Amemiya, Hiroshi

    2010-01-01

    The present probe was developed in order to measure the temperature T i of positive ions in the scrape-off layer (SOL) of tokamak where T i is usually larger than the electron temperature Ti so that the presheath in front of the probe need not be considered and the ions reach the probe with the thermal velocity. The axis of the cylindrical probe is placed parallel to the magnetic field. The important parameter are L/a, the ratio of the length to the radius of the cylindrical probe and κ, the ratio of the probe radius to (π/4) 1/2 , where is the mean ion Larmor radius. The ion current densities to the side and the end surfaces are expressed by the double integral, which can give an analytical formula with respect to the value of κ. If two electrodes with different lengths are placed parallel to the magnetic field, the difference of current densities can be reduced to κ and hence to Ti. Some examples of the application of the probe to tokamaks, JFT-2M and Textor, are demonstrated. (author)

  4. SU-E-I-81: Targeting of HER2-Expressing Tumors with Dual PET-MR Imaging Probes

    Energy Technology Data Exchange (ETDEWEB)

    Xu, P; Peng, Y; Sun, M; Yang, X [Suzhou Institute of Biomedical Engineering and Technology Chinese Academy o, Suzhou, Jiangsu (China)

    2015-06-15

    Purpose: The detection of human epidermal growth factor receptor type 2 (HER2) expression in malignant tumors provides important information influencing patient management. Radionuclide in vivo imaging of HER2 may permit the detection of HER2 in both primary tumors and metastases by a single noninvasive procedure. Trastuzumab, effective in about 15 % of women with breast cancer, downregulates signalling through the Akt/PI3K and MAPK pathways.These pathways modulate metabolism which can be monitored by positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: The relationship between response of HER2 overexpressing tumours and changes in imaging PET or SPECT and MRI will be examined by a integrated bimodal imaging probe.Small (7 kDa) high-affinity anti-HER2 Affibody molecules and KCCYSL targeting peptide may be suitable tracers for visualization of HER2-expressing tumors. Peptide-conjugated iron oxide nanoparticles (Fe3O4 NPs) as MRI imaging and CB-TE2A as PET imaging are integrated into a single synthetic molecule in the HER2 positive cancer. Results: One of targeted contrast bimodal imaging probe agents was synthesized and evaluated to target HER2-expressing tumors in a HER2 positive rat model. We will report the newest results regarding the development of bimodal imaging probes. Conclusion: The preliminary results of the bimodal imaging probe presents high correlation of MRI signal and PET imaging intensity in vivo. This unique feature can hardly be obtained by single model contrast agents. It is envisioned that this bimodal agents can hold great potential for accurate detection of HER2-expressing tumors which are critical for clinical management of the disease.

  5. Methylmercury decomposition in sediments and bacterial cultures: Involvement of methanogens and sulfate reducers in oxidative demethylation

    International Nuclear Information System (INIS)

    Oremland, R.S.; Culbertson, C.W.; Winfrey, M.R.

    1991-01-01

    The biogeochemical cycling of mercury has received considerable attention because of the toxicity of methylmercury, its bioaccumulation in biota, and its biomagnification in aquatic food chains. The formation of methylmercury is mediated primarily by microorganisms. Demethylation of monomethylmercury in freshwater and estuarine sediments and in bacterial cultures was investigated with 14 CH 3 HgI. Under anaerobiosis, results with inhibitors indicated partial involvement of both sulfate reducers and methanogens, the former dominated estuarine sediments, while both were active in freshwaters. Aerobes were the most significant demethylators in estuarine sediments, but were unimportant in freshwater sediments. Products of anaerobic demthylation were mainly 14 CO 2 as well as lesser amounts of 14 CH 4 . Acetogenic activity resulted in fixation of some 14 CO 2 produced from 14 CH 3 HgI into acetate. Aerobic demethylation in estuarine sediments produced only 14 CH 4 , while aerobic demethylation in freshwater sediments produced small amounts of both 14 CH 4 and 14 CO 2 . Two species of Desulfovibrio produced only traces of 14 CH 4 from 14 CH 3 HgI, while a culture of a methylotrophic methanogen formed traces of 14 CO 2 and 14 CH 4 when grown on trimethylamine in the presence of the 14 CH 3 HgI. These results indicate that both aerobes and anaerobes demethylate mercury in sediments, but that either group may dominate in a particular sediment type. Aerobic demethylation in the estuarine sediments appeared to proceed by the previously characterized organomercurial-lyase pathway, because methane was the sole product. This indicates the presence of an oxidative pathway, possibly one in which methylmercury serves as an analog of one-carbon substrates

  6. Free radical scavenging properties of some wine probes

    International Nuclear Information System (INIS)

    Stasko, A.; Liptakova, M.; Malik, F.

    1999-01-01

    There are preliminary results of investigation of scavenging properties of 8 probes of Slovak wines (consisting of one reference, 3 probes of white wine and 4 probes of red wine). According to the literature so far, wine probes contain paramagnetic species (Mn 2+ , characterised with sextet spectrum, and a singlet line around g=2,00). In our probes we observed Mn 2+ signals, but no significant evidence for a single line of free radical was found. We can conclude that Mn 2+ content in the red wines is generally higher than in the white ones. Further, we investigated the scavenging activities of the probes adding solution of dinitropicryl hydrazyl (DPPH-stable radical) to them. Their ability to terminate free radicals resulted in the decrease of the final DPPH concentrations in the probes. The red wines have significantly higher capability to scavenge free radicals than the probes of white wines. (authors)

  7. Where do pulse oximeter probes break?

    Science.gov (United States)

    Crede, S; Van der Merwe, G; Hutchinson, J; Woods, D; Karlen, W; Lawn, J

    2014-06-01

    Pulse oximetry, a non-invasive method for accurate assessment of blood oxygen saturation (SPO2), is an important monitoring tool in health care facilities. However, it is often not available in many low-resource settings, due to expense, overly sophisticated design, a lack of organised procurement systems and inadequate medical device management and maintenance structures. Furthermore medical devices are often fragile and not designed to withstand the conditions of low-resource settings. In order to design a probe, better suited to the needs of health care facilities in low-resource settings this study aimed to document the site and nature of pulse oximeter probe breakages in a range of different probe designs in a low to middle income country. A retrospective review of job cards relating to the assessment and repair of damaged or faulty pulse oximeter probes was conducted at a medical device repair company based in Cape Town, South Africa, specializing in pulse oximeter probe repairs. 1,840 job cards relating to the assessment and repair of pulse oximeter probes were reviewed. 60.2 % of probes sent for assessment were finger-clip probes. For all probes, excluding the neonatal wrap probes, the most common point of failure was the probe wiring (>50 %). The neonatal wrap most commonly failed at the strap (51.5 %). The total cost for quoting on the broken pulse oximeter probes and for the subsequent repair of devices, excluding replacement components, amounted to an estimated ZAR 738,810 (USD $98,508). Improving the probe wiring would increase the life span of pulse oximeter probes. Increasing the life span of probes will make pulse oximetry more affordable and accessible. This is of high priority in low-resource settings where frequent repair or replacement of probes is unaffordable or impossible.

  8. Development of high pressure conductivity probe (HPCP) for secondary shut down system (SDS-2) of 500 MWe PHWR

    International Nuclear Information System (INIS)

    Sapra, M.K.; Kundu, S.; Mohan, L.R.

    2003-09-01

    The poison solution and the moderator in Secondary Shutdown System (SDS-2) of 500 MWe PHWR, are separated by their own liquid in liquid interface. This interface moves towards the calandria because of molecular diffusion, temperature difference and physical disturbances in the moderator level. It is proposed to install two numbers of high pressure conductivity probes (HPCP) to monitor the interface movement as well as to provide the safe annunciation value for interface location. On actuation of the SDS-2 signal, high-pressure helium will inject the poison into the moderator to shutdown the reactor. During poison injection, these probes will experience high pressure of nearly 85 kg/sq.cm. Global market survey indicated that conductivity probes having built in temperature sensor are available for a maximum pressure rating of 35 kg/sq.cm. Hence in order to meet the process requirement of SDS-2, the development of HPCP suitable for a pressure of 85 kg/sq.cm. was taken up. Two numbers of such probes were successfully designed, fabricated and evaluated for their performance. The developed conductivity probes fully meet the laid design and performance criteria. The aforesaid development work was a successful endeavour towards indigenisation of high-pressure conductivity probe for future applications. This report deals with the design aspects, fabrication technique, material and performance evajuation criteria and test results of HPCP. (author)

  9. Scanning vector Hall probe microscopy

    International Nuclear Information System (INIS)

    Cambel, V.; Gregusova, D.; Fedor, J.; Kudela, R.; Bending, S.J.

    2004-01-01

    We have developed a scanning vector Hall probe microscope for mapping magnetic field vector over magnetic samples. The microscope is based on a micromachined Hall sensor and the cryostat with scanning system. The vector Hall sensor active area is ∼5x5 μm 2 . It is realized by patterning three Hall probes on the tilted faces of GaAs pyramids. Data from these 'tilted' Hall probes are used to reconstruct the full magnetic field vector. The scanning area of the microscope is 5x5 mm 2 , space resolution 2.5 μm, field resolution ∼1 μT Hz -1/2 at temperatures 10-300 K

  10. Performance evaluation of corrosion probes in simulated WVNS tank 8D-2 waste: WVNS tank farm process support

    International Nuclear Information System (INIS)

    Elmore, M.R.

    1994-07-01

    Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at ∼150 degrees F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ''time-averaged'' value of the corrosion rate. The other approach uses a shorter period of time (relative to the length of the test) in the calculation of corrosion rate, and is referred to as the ''instantaneous'' rate. The interpretation of the probe data and the implications of corrosion rates calculated with either of these methods are discussed in this report

  11. Comparative study of 2 surgical techniques for castration of guinea pigs (Cavia porcellus).

    Science.gov (United States)

    Guilmette, Josée; Langlois, Isabelle; Hélie, Pierre; El Warrak, Alexander de Oliveira

    2015-10-01

    The objective of this study was to compare 2 surgical approaches (scrotal or abdominal) for castration of guinea pigs and to investigate post-operative infection rates with either technique. Forty-eight guinea pigs were castrated by scrotal or abdominal technique after being randomly assigned to 1 of 2 groups (n = 24). Individuals were either castrated by an experienced exotic animal surgeon (n = 12) or by an experienced small animal surgeon (n = 12). Surgical wounds were evaluated daily before euthanasia for histological evaluation 2 wks after surgery. Post-operative infection rate was significantly higher in the scrotal group than in the abdominal group, with a higher rate for the experienced small animal surgeon. Castration of guinea pigs with the abdominal technique is significantly faster and has a significantly lower post-operative infection rate than the scrotal technique.

  12. Probing dopamine transporter structure and function by Zn2+-site engineering

    DEFF Research Database (Denmark)

    Loland, Claus Juul; Norgaard-Nielsen, Kristine; Gether, Ulrik

    2003-01-01

    , it will be described how we have used Zn2+-binding sites as a tool to probe the structure and function of Na+/Cl--coupled biogenic amine transporters with specific focus on the human DAT (hDAT). The work has not only led to the definition of the first structural constrains in the tertiary structure of this class...

  13. Amino acid detection using fluoroquinolone–Cu2+ complex as a switch-on fluorescent probe by competitive complexation without derivatization

    International Nuclear Information System (INIS)

    Farokhcheh, Alireza; Alizadeh, Naader

    2014-01-01

    In this work, we describe the use of fluoroquinolone–Cu 2+ complex as a competitive switch-on fluorescence probe for amino acid determination without derivatization. The fluorescence intensity of this probe, which has been reduced due to effective quenching by Cu 2+ ion, increases drastically by an addition of amino acid (glycine, phenylalanine, sarcosine, aspargine, alanine, proline, arginine, aspartic acid, glutamic acid, lysine, leucine and isoleucine). The overall stability constants of Cu 2+ ion complexes with amino acids were determined by fluorometric titration of fluoroquinolone-Cu 2+ complex with the amino acid solution. Furthermore, the probe shows high calibration sensitivity toward aspartic acid. The fluorescence signal depends linearly on the amino acid concentration within the range of concentration from 1.2×10 −7 to 1.1×10 −5 mol L −1 for aspartic acid. The detection limit was found 2.7×10 −8 mol L −1 with the relative standard deviation (RSD%) about 2.1% (five replicate). -- Highlights: • Amino acids are detected by using fluoroquinolone–Cu 2+ complex as fluorescent probe. • Amino acids were detected based on a competitive complexation reaction. • Probe has been able to recognize amino acids through switch-on fluorescence behavior. • Ultra-trace level of aspartic and glutamic acid is determined without derivatization

  14. Neutrons as a probe

    International Nuclear Information System (INIS)

    Iizumi, Masashi

    1993-01-01

    As an introduction to the symposium a brief overview will be given about the features of neutrons as a probe. First it will be pointed out that the utilization of neutrons as a probe for investigating the structural and dynamical properties of condensed matters is a benign gift eventuated from the release of atomic energy initiated by Enrico Fermi exactly half century ago. Features of neutrons as a probe are discussed in accordance with the four basic physical properties of neutrons as an elementary particle; (1) no electric charge (the interaction with matter is nuclear), (2) the mass of neutron is 1 amu, (3) spin is 1/2 and (4) neutrons have magnetic dipole moment. Overview will be given on the uniqueness of neutrons as a probe and on the variety in the way they are used in the wide research area from the pure science to the industrial applications. (author)

  15. β-Isocyanoalanine as an IR probe: comparison of vibrational dynamics between isonitrile and nitrile-derivatized IR probes.

    Science.gov (United States)

    Maj, Michał; Ahn, Changwoo; Kossowska, Dorota; Park, Kwanghee; Kwak, Kyungwon; Han, Hogyu; Cho, Minhaeng

    2015-05-07

    An infrared (IR) probe based on isonitrile (NC)-derivatized alanine 1 was synthesized and the vibrational properties of its NC stretching mode were investigated using FTIR and femtosecond IR pump-probe spectroscopy. It is found that the NC stretching mode is very sensitive to the hydrogen-bonding ability of solvent molecules. Moreover, its transition dipole strength is larger than that of nitrile (CN) in nitrile-derivatized IR probe 2. The vibrational lifetime of the NC stretching mode is found to be 5.5 ± 0.2 ps in both D2O and DMF solvents, which is several times longer than that of the azido (N3) stretching mode in azido-derivatized IR probe 3. Altogether these properties suggest that the NC group can be a very promising sensing moiety of IR probes for studying the solvation structure and dynamics of biomolecules.

  16. Ultrasonic immersion probes characterization for use in nondestructive testing according to EN 12668-2:2001

    International Nuclear Information System (INIS)

    Silva, C E R; Alvarenga, A V; Costa-Felix, R P B

    2011-01-01

    Ultrasound is often used as a Non-Destructive Testing (NDT) technique to analyze components and structures to detect internal and surface flaws. To guarantee reliable measurements, it is necessary to calibrate instruments and properly assess related uncertainties. An important device of an ultrasonic instrument system is its probe, which characterization should be performed according to EN 12668-2. Concerning immersion probes beam profile, the parameters to be assessed are beam divergence, focal distance, width, and zone length. Such parameters are determined by scanning a reflector or a hydrophone throughout the transducer beam. Within the present work, a methodology developed at Inmetro's Laboratory of Ultrasound to evaluate relevant beam parameters is presented, based on hydrophone scan. Water bath and positioning system to move the hydrophone were used to perform the scan. Studied probes were excited by a signal generator, and the waterborne signals were detected by the hydrophone and acquired using an oscilloscope. A user-friendly virtual instrument was developed in LabVIEW to automate the system. The initial tests were performed using 1 and 2.25 MHz-ultrasonic unfocused probes (Oe 1.27 cm), and results were consistent with the manufacturer's specifications. Moreover, expanded uncertainties were lower than 6% for all parameters under consideration.

  17. Ultrasonic immersion probes characterization for use in nondestructive testing according to EN 12668-2:2001

    Science.gov (United States)

    Silva, C. E. R.; Alvarenga, A. V.; Costa-Felix, R. P. B.

    2011-02-01

    Ultrasound is often used as a Non-Destructive Testing (NDT) technique to analyze components and structures to detect internal and surface flaws. To guarantee reliable measurements, it is necessary to calibrate instruments and properly assess related uncertainties. An important device of an ultrasonic instrument system is its probe, which characterization should be performed according to EN 12668-2. Concerning immersion probes beam profile, the parameters to be assessed are beam divergence, focal distance, width, and zone length. Such parameters are determined by scanning a reflector or a hydrophone throughout the transducer beam. Within the present work, a methodology developed at Inmetro's Laboratory of Ultrasound to evaluate relevant beam parameters is presented, based on hydrophone scan. Water bath and positioning system to move the hydrophone were used to perform the scan. Studied probes were excited by a signal generator, and the waterborne signals were detected by the hydrophone and acquired using an oscilloscope. A user-friendly virtual instrument was developed in LabVIEW to automate the system. The initial tests were performed using 1 and 2.25 MHz-ultrasonic unfocused probes (Ø 1.27 cm), and results were consistent with the manufacturer's specifications. Moreover, expanded uncertainties were lower than 6% for all parameters under consideration.

  18. Small Molecules and Sum Frequency Generation Probes of Nanoparticulate TiO2

    Science.gov (United States)

    Shultz, Mary Jane

    2006-03-01

    Anatase TiO2 is known to photo catalytically mineralize a wide variety of pollutants and pathogens, both airborne and in aqueous solution. One of the major benefits of basing water treatment systems on TiO2 is that it is environmentally benign and so non toxic that it is used as a colorant in creamy salad dressing. The primary impediment to wide spread implementation of a TiO2 based system for water decontamination is that the quantum efficiency in contact with condense phase water is less than 5%. Since the quantum efficiency for destruction of airborne materials is greater than 80%, the potential for increased efficiency is very real. To convert the potential to practice, the oxidation mechanism needs to be more fully understood. We will report on the results of using a nonlinear optical spectroscopy, sum frequency generation (SFG) as an in situ probe of interactions at the TiO2 surface. Results suggest that the dominant oxidation mechanism converts from a direct to an indirect mechanism as the water content (vapor pressure) increases. This presentation will discuss the probe technique as well as the results.

  19. Experimental Route to Scanning Probe Hot Electron Nanoscopy (HENs) Applied to 2D Material

    KAUST Repository

    Giugni, Andrea; Torre, Bruno; Allione, Marco; Das, Gobind; Wang, Zhenwei; He, Xin; Alshareef, Husam N.; Di Fabrizio, Enzo M.

    2017-01-01

    for applications in electronics: 2D MoS2 single crystal and a p-type SnO layer. Results are supported by complementary scanning Kelvin probe microscopy, traditional conductive AFM, and Raman measurements. New features highlighted by HEN technique reveal details

  20. In-Situ Probing Plasmonic Energy Transfer in Cu(In, Ga)Se2 Solar Cells by Ultrabroadband Femtosecond Pump-Probe Spectroscopy.

    Science.gov (United States)

    Chen, Shih-Chen; Wu, Kaung-Hsiung; Li, Jia-Xing; Yabushita, Atsushi; Tang, Shih-Han; Luo, Chih Wei; Juang, Jenh-Yih; Kuo, Hao-Chung; Chueh, Yu-Lun

    2015-12-18

    In this work, we demonstrated a viable experimental scheme for in-situ probing the effects of Au nanoparticles (NPs) incorporation on plasmonic energy transfer in Cu(In, Ga)Se2 (CIGS) solar cells by elaborately analyzing the lifetimes and zero moment for hot carrier relaxation with ultrabroadband femtosecond pump-probe spectroscopy. The signals of enhanced photobleach (PB) and waned photoinduced absorption (PIA) attributable to surface plasmon resonance (SPR) of Au NPs were in-situ probed in transient differential absorption spectra. The results suggested that substantial carriers can be excited from ground state to lower excitation energy levels, which can reach thermalization much faster with the existence of SPR. Thus, direct electron transfer (DET) could be implemented to enhance the photocurrent of CIGS solar cells. Furthermore, based on the extracted hot carrier lifetimes, it was confirmed that the improved electrical transport might have been resulted primarily from the reduction in the surface recombination of photoinduced carriers through enhanced local electromagnetic field (LEMF). Finally, theoretical calculation for resonant energy transfer (RET)-induced enhancement in the probability of exciting electron-hole pairs was conducted and the results agreed well with the enhanced PB peak of transient differential absorption in plasmonic CIGS film. These results indicate that plasmonic energy transfer is a viable approach to boost high-efficiency CIGS solar cells.

  1. Intraoperative tumor detection: Relative performance of single-element, dual-element, and imaging probes with various collimators

    International Nuclear Information System (INIS)

    Hartsough, N.E.; Barrett, H.H.; Barber, H.B.; Woolfenden, J.M.

    1995-01-01

    Accurate tumor staging depends on finding all tumor sites, and curative surgery requires the removal of all cancerous tissue from those sites. One technique for locating tumors is to inject patients before surgery with a radiotracer that is preferentially taken up by cancerous tissue. Then, an intraoperative gamma-sensitive probe is used to locate the tumors. Small (< 1-cm diameter) tumors, often undetectable by external imaging and by the standard surgical inspection with sight and touch, can be found with probes. Simple calculations and measurements with radioactive tumor models show that small tumors should be detected by single-element probes, but often such probes fail to detect these small tumors in practice. This discrepancy is often caused by the use of a uniform background to predict probe performance. Real backgrounds are nonuniform and can decrease probe performance dramatically. Dual-element, coincidence, or imaging probes may solve the background problem. The authors devised a method to predict probe performance in a realistic background which includes variations in normal organ uptakes. They predict the relative performance of both existing probes and those in the design stage so that optimal detector and collimator configurations can be determined. The procedure includes a Monte-Carlo-calculated point-response function, a numerical torso phantom, and measured biodistribution of a monoclonal antibody. The Hotelling Trace Value, a measure of tumor-detection performance, is computed from the probe responses in simulated studies

  2. Pediatric abdominal non-Hodgkin's lymphoma: diagnosis through surgical and non-surgical procedures.

    Science.gov (United States)

    Aguiar, Arthur Almeida; Lima, Luciana Cavalvanti; Araújo, Cláudia Corrêa de; Gallindo, Rodrigo Melo

    2017-12-29

    To describe the success rate and the complications after procedures to diagnose abdominal non-Hodgkin's lymphoma in children and adolescents. A retrospective cross-sectional study was conducted with a population consisting of children and adolescents with abdominal non-Hodgkin's lymphoma diagnosed between September 1994 and December 2012. The sample comprised of 100 patients who underwent 113 diagnostic procedures, including urgent surgery (n=21), elective surgery (n=36), and non-surgical diagnosis (n=56). The most frequent procedures were laparotomy (46.9%) and ultrasound-guided core biopsy (25.6%). The rate of diagnostic success was 95.2% for urgent surgeries; 100% for elective surgeries and 82.1% for non-surgical procedures (p<0.05). The rates of complication during the three diagnosis procedures considered were significant (p<0.001; 95.2% of the urgent surgeries, 83.8% of the elective surgeries, and 10.7% of the non-surgical procedures). The length of time before resuming a full diet and starting chemotherapy was significantly reduced for patients who underwent non-surgical procedures when compared with the other procedures (p<0.001). Non-surgical procedures for the diagnosis of pediatric abdominal non-Hodgkin's lymphoma are an effective option with low morbidity rate, allowing an earlier resumption of a full diet and chemotherapy initiation. Furthermore, non-surgical procedures should also be considered for obtaining tumor samples from patients with extensive disease. Copyright © 2017. Published by Elsevier Editora Ltda.

  3. Improved yield of high resolution mercuric iodide gamma-ray spectrometers

    International Nuclear Information System (INIS)

    Gerrish, V.; van den Berg, L.

    1990-01-01

    Mercuric iodide (HgI 2 ) exhibits properties which make it attractive for use as a solid state nuclear radiation detector. The wide bandgap (E g = 2.1 eV) and low dark current allow room temperature operation, while the high atomic number provides a large gamma-ray cross section. However, poor hole transport has been a major limitation in the routine fabrication of high-resolution spectrometers using this material. This paper presents the results of gamma-ray response and charge transport parameter measurements conducted during the past year at EG ampersand G/EM on 96 HgI 2 spectrometers. The gamma-ray response measurements reveal that detector quality is correlated with the starting material used in the crystal growth. In particular, an increased yield of high-resolution spectrometers was obtained from HgI 2 which was synthesized by precipitation from an aqueous solution, as opposed to using material from commercial vendors. Data are also presented which suggest that better spectrometer performance is tied to improved hole transport. Finally, some initial results on a study of detector uniformity reveal spatial variations which may explain why the correlation between hole transport parameters and spectrometer performance is sometimes violated. 6 refs., 3 figs

  4. Radiation Protection Considerations about gamma probe-guided intraoperative sentinel lymph node surgery

    International Nuclear Information System (INIS)

    Rodriguez, C.; Jimenez-Hoyuela Garcia, J. L.; Rebollo Aguirre, J. M.; Custodio, A.

    2002-01-01

    The sentinel node concept is based on the sequential dissemination hypothesis. According to it, there's a lymph node (named sentinel node) which is the first receiving cancer cells metastasizing from a primary tumor. Further, others nodes sequentially located might be affected. Surgical performance for several types of cancer includes the complete removal of the tumor and a complete local lymph node dissection (LND). so removing and analyzing the sentinel node may avoid the complete LND. To locate the sentinel node, it's usual the local administration (intradermal injection) of a radiopharmaceutical Tc-99, sulfur colloid (activity about 1 mCi( several hours prior to surgery, and using an intraoperative gamma probe very sensitive to the gamma radiation. Although the activity is injected by the Nuclear Medicine staff, and be exposed to the gamma radiation. In this study we estimated maximum possible doses that would be received by personnel (surgical staff during surgery and pathologists during lumpectomy of the sentinel node). For the surgical staff, to avoid dose errors due to the very low residual activities and not to interfere with the personnel in the surgery room, we estimated doses by taking into account only the physical decay of Tc99m injected. for the pathologists, we estimated the residual activity in the sentinel node with the gamma probe. The highest effective dose rate found was to the surgeon (o,44 μSv/h, respectively. so a surgeon could perform 407 hours/yr, and a pathologist 1717 hours/yr, dedicated exclusively to sentinel node biopsy, before being classified as professionally exposed to radiation, and 4070 and 17170 hours per year, respectively, to surpass the annual limits (national regulations of the European Communities). In short, radiation doses to clinical staff involved in the technique are low, and in normal conditions, by establishing appropriate procedures (precautions during surgery, during manipulation surgical specimen...) control

  5. The effect of consuming low- versus high-glycemic index meals after exercise on postprandial blood lipid response following a next-day high-fat meal

    Science.gov (United States)

    Kaviani, M; Chilibeck, P D; Yee, P; Zello, G A

    2016-01-01

    Background/Objectives: Exercise performed shortly before (that is, within half a day of) a high-fat meal is beneficial for stimulating fat oxidation after the meal and reducing postprandial triglycerides (TG). This benefit of exercise is unfortunately negated if the after-exercise food choice to replace the calories expended during exercise is one containing high-glycemic index (HGI) carbohydrates. We determined the effect of consuming low-glycemic index (LGI) carbohydrates after an exercise session on fat oxidation and TG after a subsequent high-fat meal. Subjects/Methods: Using a randomized, counterbalanced crossover design, 23 overweight or obese individuals (body mass index ⩾25 kg m−2) performed: walking exercise (90 min) at 1800 h followed by no meal (EX); exercise followed by a meal with LGI carbohydrates (that is, lentils, EX-LGI); exercise followed by a meal with HGI carbohydrates (that is, instant potatoes, white bread, EX-HGI); and a control condition with no exercise or meal. After a 10-h overnight fast, participants were given a standardized high-fat meal. Fat oxidation was estimated before and for 6 h after this meal from respiratory gas measures and TG determined from blood samples. Results: Fat oxidation (mean±s.d.) was higher with EX (6.9±1.7 g h−1) than EX-HGI (6.3±1.6 g h−1; P=0.007) and Control (5.9±1.7 g h−1; P=0.00002), and EX-LGI (6.6±1.7 g h−1) was higher than Control (P=0.002). TG total area under the curve was 18–32% lower with EX and EX-LGI compared with control (P=0.0005 and P=0.0001, respectively) and EX-HGI (P=0.05 and P=0.021, respectively). Conclusions: A meal containing HGI carbohydrates consumed after an evening exercise session cancels the beneficial effect of exercise for stimulating fat oxidation and lowering TG after a subsequent high-fat meal, whereas consuming a post-exercise meal with LGI carbohydrates retains the positive effect of exercise. PMID:27376698

  6. Probing convex polygons with X-rays

    International Nuclear Information System (INIS)

    Edelsbrunner, H.; Skiena, S.S.

    1988-01-01

    An X-ray probe through a polygon measures the length of intersection between a line and the polygon. This paper considers the properties of various classes of X-ray probes, and shows how they interact to give finite strategies for completely describing convex n-gons. It is shown that (3n/2)+6 probes are sufficient to verify a specified n-gon, while for determining convex polygons (3n-1)/2 X-ray probes are necessary and 5n+O(1) sufficient, with 3n+O(1) sufficient given that a lower bound on the size of the smallest edge of P is known

  7. Amino acid detection using fluoroquinolone–Cu{sup 2+} complex as a switch-on fluorescent probe by competitive complexation without derivatization

    Energy Technology Data Exchange (ETDEWEB)

    Farokhcheh, Alireza; Alizadeh, Naader, E-mail: alizaden@modares.ac.ir

    2014-01-15

    In this work, we describe the use of fluoroquinolone–Cu{sup 2+} complex as a competitive switch-on fluorescence probe for amino acid determination without derivatization. The fluorescence intensity of this probe, which has been reduced due to effective quenching by Cu{sup 2+} ion, increases drastically by an addition of amino acid (glycine, phenylalanine, sarcosine, aspargine, alanine, proline, arginine, aspartic acid, glutamic acid, lysine, leucine and isoleucine). The overall stability constants of Cu{sup 2+} ion complexes with amino acids were determined by fluorometric titration of fluoroquinolone-Cu{sup 2+} complex with the amino acid solution. Furthermore, the probe shows high calibration sensitivity toward aspartic acid. The fluorescence signal depends linearly on the amino acid concentration within the range of concentration from 1.2×10{sup −7} to 1.1×10{sup −5} mol L{sup −1} for aspartic acid. The detection limit was found 2.7×10{sup −8} mol L{sup −1} with the relative standard deviation (RSD%) about 2.1% (five replicate). -- Highlights: • Amino acids are detected by using fluoroquinolone–Cu{sup 2+} complex as fluorescent probe. • Amino acids were detected based on a competitive complexation reaction. • Probe has been able to recognize amino acids through switch-on fluorescence behavior. • Ultra-trace level of aspartic and glutamic acid is determined without derivatization.

  8. Abortion - surgical

    Science.gov (United States)

    Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...

  9. Nanobits: customizable scanning probe tips

    DEFF Research Database (Denmark)

    Kumar, Rajendra; Shaik, Hassan Uddin; Sardan Sukas, Özlem

    2009-01-01

    We present here a proof-of-principle study of scanning probe tips defined by planar nanolithography and integrated with AFM probes using nanomanipulation. The so-called 'nanobits' are 2-4 mu m long and 120-150 nm thin flakes of Si3N4 or SiO2, fabricated by electron beam lithography and standard s...

  10. Post surgical complications from students' large animal surgical ...

    African Journals Online (AJOL)

    A retrospective study of post surgical complications was conducted on records of students' Large Animal Surgical Laboratories in the Faculty of Veterinary Medicine (F.V.M.), Ahmadu Bello University (A.B.U), Zaria from 1989 to 1993. Three hundred and eleven surgical complications were recorded from five surgical ...

  11. Towards optical fibre based Raman spectroscopy for the detection of surgical site infection

    Science.gov (United States)

    Thompson, Alex J.; Koziej, Lukasz; Williams, Huw D.; Elson, Daniel S.; Yang, Guang-Zhong

    2016-03-01

    Surgical site infections (SSIs) are common post-surgical complications that remain significant clinical problems, as they are associated with substantial mortality and morbidity. As such, there is significant interest in the development of minimally invasive techniques that permit early detection of SSIs. To this end, we are applying a compact, clinically deployable Raman spectrometer coupled to an optical fibre probe to the study of bacteria, with the long term goal of using Raman spectroscopy to detect infection in vivo. Our system comprises a 785 nm laser diode for excitation and a commercial (Ocean Optics, Inc.) Raman spectrometer for detection. Here we discuss the design, optimisation and validation of this system, and describe our first experiences interrogating bacterial cells (Escherichia coli) in vitro.

  12. Probing the pre-reactive a Cl (2P) + H2(D2) Van der Waals well through the photodetachment spectroscopy of Cl- H2(D2). CP-31

    International Nuclear Information System (INIS)

    Ghosal, Subhas; Mahapatra, Susanta

    2004-01-01

    The photodetachment spectrum of ClH 2 - and ClD 2 , probing the van der Waals well region of the reactive Cl( 2 P) + H 2 (D 2 ) potential energy surface, is theoretically calculated and compared with the experiment. A time-dependent wave packet approach is employed using the Capecchi-Werner coupled multi-sheeted ab initio potential energy surfaces of neutral ClH 2 for this purpose

  13. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    International Nuclear Information System (INIS)

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  14. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Directory of Open Access Journals (Sweden)

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  15. Gamma-ray detectors for intelligent, hand-held radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1983-01-01

    Small radiation detectors based on HgI 2 , bismuth germanate (BGO), plastic, or NaI(Tl) detector materials were evaluated for use in small, lighweight radiation monitors. The two denser materials, HgI 2 and BGO, had poor resolution at low-energy and thus performed less well than NaI(Tl) in detecting low-energy gamma rays from bare, enriched uranium. The plastic scintillator, a Compton recoil detector, also performed less well at low gamma-ray energy. Two small NaI(Tl) detectors were suitable for detecting bare uranium and sheilded plutonium. One became part of a new lightweight hand-held monitor and the other found uses as a pole-mounted detector for monitoring hard-to-reach locations

  16. Vibrational dynamics of aqueous hydroxide solutions probed using broadband 2DIR spectroscopy

    International Nuclear Information System (INIS)

    Mandal, Aritra; Tokmakoff, Andrei

    2015-01-01

    We employed ultrafast transient absorption and broadband 2DIR spectroscopy to study the vibrational dynamics of aqueous hydroxide solutions by exciting the O–H stretch vibrations of the strongly hydrogen-bonded hydroxide solvation shell water and probing the continuum absorption of the solvated ion between 1500 and 3800 cm −1 . We observe rapid vibrational relaxation processes on 150–250 fs time scales across the entire probed spectral region as well as slower vibrational dynamics on 1–2 ps time scales. Furthermore, the O–H stretch excitation loses its frequency memory in 180 fs, and vibrational energy exchange between bulk-like water vibrations and hydroxide-associated water vibrations occurs in ∼200 fs. The fast dynamics in this system originate in strong nonlinear coupling between intra- and intermolecular vibrations and are explained in terms of non-adiabatic vibrational relaxation. These measurements indicate that the vibrational dynamics of the aqueous hydroxide complex are faster than the time scales reported for long-range transport of protons in aqueous hydroxide solutions

  17. Access to Specialized Surgical Care

    African Journals Online (AJOL)

    The ANNALS of AFRICAN SURGERY. January 2016 Volume 13 Issue 1 1. EDITORIAL. Access to Specialized Surgical Care. Saidi H. University of Nairobi. Correspondence to: Prof Hassan Saidi, P.O Box 30196-00100, Nairobi. Email: hsaid2ke@yahoo.com. Ann Afr Surg. 2016;13(1):1-2. The narrative of surgical disease in ...

  18. A quinoline-based Cu2 + ion complex fluorescence probe for selective detection of inorganic phosphate anion in aqueous solution and its application to living cells

    Science.gov (United States)

    Dai, Yanpeng; Wang, Peng; Fu, Jiaxin; Yao, Kun; Xu, Kuoxi; Pang, Xiaobin

    2017-08-01

    A quinaldine functionalized probe QP has been designed and synthesized. It exhibited selective turn-off fluorescence response toward Cu2 + ion over most of the biologically important ions at physiological pH. The binding ratio of the probe QP and Cu2 + ion was determined to be 1:1 through fluorescence titration, Job's plot and ESI-MS. The binding constant (K) of Cu2 + to probe QP was found to be 2.12 × 104 M- 1. Further, the Cu2 + ensemble of probe QP was found to respond H2PO4- and HPO42 - among other important biological anions via fluorescence turn-on response at physiological pH. Fluorescence microscopy imaging using living Hela cells showed that probe QP could be used as an effective fluorescent probe for detecting Cu2 + cation and H2PO4- and HPO42 - anions in living cells.

  19. Computer modelling of eddy current probes

    International Nuclear Information System (INIS)

    Sullivan, S.P.

    1992-01-01

    Computer programs have been developed for modelling impedance and transmit-receive eddy current probes in two-dimensional axis-symmetric configurations. These programs, which are based on analytic equations, simulate bobbin probes in infinitely long tubes and surface probes on plates. They calculate probe signal due to uniform variations in conductor thickness, resistivity and permeability. These signals depend on probe design and frequency. A finite element numerical program has been procured to calculate magnetic permeability in non-linear ferromagnetic materials. Permeability values from these calculations can be incorporated into the above analytic programs to predict signals from eddy current probes with permanent magnets in ferromagnetic tubes. These programs were used to test various probe designs for new testing applications. Measurements of magnetic permeability in magnetically biased ferromagnetic materials have been performed by superimposing experimental signals, from special laboratory ET probes, on impedance plane diagrams calculated using these programs. (author). 3 refs., 2 figs

  20. Interphase FISH detection of BCL2 rearrangement in follicular lymphoma using breakpoint-flanking probes

    NARCIS (Netherlands)

    Vaandrager, J W; Schuuring, E; Raap, T; Philippo, K; Kleiverda, K; Kluin, P

    Rearrangement of the BCL2 gene is an important parameter for the differential diagnosis of non-Hodgkin lymphomas. Although a relatively large proportion of breakpoints is clustered, many are missed by standard PCR. A FISH assay is therefore desired. Up to now, a lack of probes flanking the BCL2 gene

  1. Surgical lighting

    NARCIS (Netherlands)

    Knulst, A.J.

    2017-01-01

    The surgical light is an important tool for surgeons to create and maintain good visibility on the surgical task. Chapter 1 gives background to the field of (surgical) lighting and related terminology. Although the surgical light has been developed strongly since its introduction a long time ago,

  2. Surgical smoke.

    Science.gov (United States)

    Fan, Joe King-Man; Chan, Fion Siu-Yin; Chu, Kent-Man

    2009-10-01

    Surgical smoke is the gaseous by-product formed during surgical procedures. Most surgeons, operating theatre staff and administrators are unaware of its potential health risks. Surgical smoke is produced by various surgical instruments including those used in electrocautery, lasers, ultrasonic scalpels, high speed drills, burrs and saws. The potential risks include carbon monoxide toxicity to the patient undergoing a laparoscopic operation, pulmonary fibrosis induced by non-viable particles, and transmission of infectious diseases like human papilloma virus. Cytotoxicity and mutagenicity are other concerns. Minimisation of the production of surgical smoke and modification of any evacuation systems are possible solutions. In general, a surgical mask can provide more than 90% protection to exposure to surgical smoke; however, in most circumstances it cannot provide air-tight protection to the user. An at least N95 grade or equivalent respirator offers the best protection against surgical smoke, but whether such protection is necessary is currently unknown.

  3. "Two-step" technique with OsiriXTM to evaluate feasibility of C2 pedicle for surgical fixation

    Directory of Open Access Journals (Sweden)

    Luis Miguel Sousa Marques

    2016-01-01

    Full Text Available Background: Surgical treatment of craniovertebral junction pathology has evolved considerably in recent decades with the implementation of short atlanto-axial fixation techniques, notwhithstanding increasing neurovascular risks. Also, there is strong evidence that fixation of C2 anatomical pedicle has the best biomechanical profile of the entire cervical spine. However, it is often difficult and misleading, to evaluate anatomical bony and vascular anomalies using the three orthogonal planes (axial, coronal, and sagittal of CT. Objectives: The authors describe an innovative and simple technique to evaluate the feasibility of C2 pedicle for surgical screw fixation using preoperative planning with the free DICOM (Digital Imaging and Communications in Medicine software OsiriX TM . Materials and Methods: The authors report the applicatin of this novel technique in 5 cases (3 traumatic, 1 Os Odontoideum, and 1 complex congenital malformation collected from our general case series of the Department in the last 5 years. Results: In this "proof of concept" study, the pre-operative analysis with the "two-step" tecnique was detrimental for choosing the surgical tecnique. Detailed post-operative analysis confirmed correct position of C2 screws without cortical breach. There were no complications or mortality reported. Conclusion: This "two-step" technique is an easy and reliable way to determine the feasibility of C2 pedicle for surgical fixation. The detailed tridimensional radiological preoperative evaluation of craniovertebral junction anatomy is critical to the sucess and safety of this surgeries, and can avoid, to certain degree, expensive intra-operative tridimensional imaging facilities.

  4. Evaluation of the Gen-Probe DNA probe for the detection of legionellae in culture

    International Nuclear Information System (INIS)

    Edelstein, P.H.

    1986-01-01

    A commercial DNA probe kit designed to detect rRNA from legionellae was evaluated for its ability to correctly discriminate between legionellae and non-legionellae taken from culture plates. The probe kit, made by the Gen-Probe Corp. (San Diego, Calif.), was radiolabeled with 125 I, and probe bacterial RNA hybridization, detected in a simple one-tube system hybridization assay, was quantitated with a gamma counter. A total of 156 Legionella sp. strains were tested, of which 125 were Legionella pneumophila and the remainder were strains from 21 other Legionella spp. A total of 106 gram-negative non-legionellae, isolated from human respiratory tract (81%) and other body site (19%) specimens, were also tested; 14 genera and 28 species were represented. The probe easily distinguished all of the legionellae from the non-legionellae. The average legionellae/non-legionellae hybridization ratio was 42:1, and the lowest ratio was 2:1; a minor modification in the procedure increased the lowest ratio to 5:1. In addition to correctly identifying all Legionella species, the probe was able to separate some of the various species of Legionella. L. pneumophila strains hybridized more completely to the probe than did the other Legionella spp.; L. wadsworthii and L. oakridgensis hybridized only about 25% of the probe relative to L. pneumophila. Some strains of phenotypically identified L. pneumophila had much lower hybridization to the probe than other members of the species and may represent a new Legionella species. The simplicity of the technique and specificity of the probe make it a good candidate for confirming the identity of legionellae in culture

  5. Anti-HER2 immunoliposomes for selective delivery of electron paramagnetic resonance imaging probes to HER2-overexpressing breast tumor cells

    Science.gov (United States)

    Burks, Scott R.; Macedo, Luciana F.; Barth, Eugene D.; Tkaczuk, Katherine H.; Martin, Stuart S.; Rosen, Gerald M.; Halpern, Howard J.; Brodie, Angela M.

    2014-01-01

    Electron paramagnetic resonance (EPR) imaging is an emerging modality that can detect and localize paramagnetic molecular probes (so-called spin probes) in vivo. We previously demonstrated that nitroxide spin probes can be encapsulated in liposomes at concentrations exceeding 100 mM, at which nitroxides exhibit a concentration-dependent quenching of their EPR signal that is analogous to the self-quenching of fluorescent molecules. Therefore, intact liposomes encapsulating high concentrations of nitroxides exhibit greatly attenuated EPR spectral signals, and endocytosis of such liposomes represents a cell-activated contrast-generating mechanism. After endocytosis, the encapsulated nitroxide is liberated and becomes greatly diluted in the intracellular milieu. This dequenches the nitroxides to generate a robust intracellular EPR signal. It is therefore possible to deliver a high concentration of nitroxides to cells while minimizing background signal from unendocytosed liposomes. We report here that intracellular EPR signal can be selectively generated in a specific cell type by exploiting its expression of Human Epidermal Growth Factor Receptor 2 (HER2). When targeted by anti-HER2 immunoliposomes encapsulating quenched nitroxides, Hc7 cells, which are novel HER2-overexpressing cells derived from the MCF7 breast tumor cell line, endocytose the liposomes copiously, in contrast to the parent MCF7 cells or control CV1 cells, which do not express HER2. HER2-dependent liposomal delivery enables Hc7 cells to accumulate 750 μM nitroxide intracellularly. Through the use of phantom models, we verify that this concentration of nitroxides is more than sufficient for EPR imaging, thus laying the foundation for using EPR imaging to visualize HER2-overexpressing Hc7 tumors in animals. PMID:20066490

  6. An assessment of chemical properties and hardgrove grindability index of punjab coal

    International Nuclear Information System (INIS)

    Shahzad, M.; Iqbal, M.M.; Hassan, S.A.

    2014-01-01

    This paper deals with the delamination of chemical properties and hardgrove grindability index (HGI) of coal samples collected from three different coal fields of Punjab; Eastern Salt Range, Central Salt Range and Makerwal coal fields. The chemical properties of Punjab coal reveal that most of the Punjab coal belongs to sub-bituminous category except coal of Tunnel C section of Makerwal Collieries and Iqbal Mineral coal mine of Dalwal, which are high volatile bituminous and lignite, respectively. The results of the research show that the HGI values of Punjab coal vary from 57 to 92. The eastern salt range coals are found to be the softest coals among that of three coal fields. It was further observed that the HGI values of the Punjab coal decrease with increasing moisture content, fixed carbon and sulphur contents, while it has a positive relation with volatile matter, ash content and gross calorific value. It was concluded that moisture content at its lower range has negligible effect on HGI of the Punjab coal. (author)

  7. Comparison of CDE data in phacoemulsification between an open hospital-based ambulatory surgical center and a free-standing ambulatory surgical center

    Directory of Open Access Journals (Sweden)

    Ming Chen

    2010-11-01

    Full Text Available Ming Chen1, Mindy Chen21University of Hawaii, Honolulu, HI, USA; 2University of California, Irvine, CA, USAAbstract: Mean CDE (cumulative dissipated energy values were compared for an open hospital-based surgical center and a free-standing surgical center. The same model of phacoemulsifier (Alcon Infiniti Ozil was used. Mean CDE values showed that surgeons (individual private practice at the free-standing surgical center were more efficient than surgeons (individual private practice at the open hospital-based surgical center (mean CDE at the hospital-based surgical center 18.96 seconds [SD = 12.51]; mean CDE at the free-standing surgical center 13.2 seconds [SD = 9.5]. CDE can be used to monitor the efficiency of a cataract surgeon and surgical center in phacoemulsification. The CDE value may be used by institutions as one of the indicators for quality control and audit in phacoemulsification.Keywords: CDE (cumulative dissipated energy, open hospital-based ambulatory surgical center, free-standing surgical center, phacoemulsification 

  8. The TORE SUPRA fast reciprocating RF probe

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.

    1994-01-01

    A fast reciprocating ICRF (Ion Cyclotron Range of Frequencies) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at ORNL. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal RF magnetic fields and the other senses poloidal RF magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/sec) of 30 cm by 2 cm, and the reciprocating mount has a slow stroke (5 cm/sec) of 30 cm and a fast stroke (1.5 m/sec) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 cm to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data shows parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  9. Pushed monocanalicular intubation versus probing as a primary management for congenital nasolacrimal obstruction

    Directory of Open Access Journals (Sweden)

    Elsawaby EA

    2016-09-01

    Full Text Available Emad Abdelaal Elsawaby, Rania Asem El Essawy, Sameh Hassan Abdelbaky, Yomna Magdy Ismail Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, Egypt Purpose: Evaluation of efficiency, complications, and advantages of pushed monocanalicular intubation using Masterka® tube versus simple probing in patients with congenital nasolacrimal duct obstruction (CNLDO.Patients and methods: This is a case-controlled study that included 60 eyes (of 53 patients; 30 eyes underwent probing and 30 eyes intubation using the Masterka tube as a primary treatment for CNLDO. The children were aged between 6 months and 36 months at the time of surgery, with no previous nasolacrimal surgical procedure, and had one or more of the following clinical signs of nasolacrimal duct obstruction: epiphora, mucous discharge, and/or increased tear lake.Results: We defined success by absence of epiphora, mucous discharge, or increased tear lake 1 month after tube removal. The overall success rate in the probing group was 80%, while it was 83.3% in the intubation group.Conclusion: Pushed monocanalicular intubation is an effective method for treatment of CNLDO; it requires only mask inhalation anesthesia and could be considered as an appropriate alternative procedure with imperceptible complications. Keywords: epiphora, probing, intubation, monocanalicular, nasolacrimal

  10. Surgical Assisting

    Science.gov (United States)

    ... instruction, including: Microbiology Pathophysiology Pharmacology Anatomy and physiology Medical terminology Curriculum . Course content includes: Advanced surgical anatomy Surgical microbiology Surgical pharmacology Anesthesia methods and agents Bioscience Ethical ...

  11. Paediatric Abdominal Surgical Emergencies in a General Surgical ...

    African Journals Online (AJOL)

    ... organized for general surgeons undertaking paediatric surgical emergencies. More paediatric surgeons should be trained and more paediatric surgical units should established in the country. Key Words: Paediatric Abdominal Surgical Emergencies; Paediatric Surgeons, General Surgeons. Journal of College of Medicine ...

  12. Flow Cytometric Applicability of Fluorescent Vitality Probes on Phytoplankton

    NARCIS (Netherlands)

    Peperzak, L.; Brussaard, C.P.D.

    2011-01-01

    The applicability of six fluorescent probes (four esterase probes: acetoxymethyl ester of Calcein [Calcein-AM], 5-chloromethylfluorescein diacetate [CMFDA], fluorescein diacetate [FDA], and 2',7'-dichlorofluorescein diacetate [H(2)DCFDA]; and two membrane probes: bis-(1,3-dibutylbarbituric acid)

  13. Assessment of Periodontal Status of Surgically Exposed and Orthodontically Aligned Impacted Maxillary Canines

    OpenAIRE

    Adina Coșarcă; Mariana Păcurar; Cecilia Petrovan; Alina Ormenișan

    2014-01-01

    Aim: The aim of this study was to compare the periodontal status of impacted canines after 5 years following completion of the combined surgical and orthodontic treatment. Materials and methods: We examined 20 labially impacted canines and 20 palatally impacted canines at 5 years after the end of treatment. We assessed the periodontal status of these teeth. Results: Different outcomes were found regarding the probing depth and the amount of keratinized gingiva in the two mentioned groups of t...

  14. The ML1Nx2 Phosphatidylinositol 3,5-Bisphosphate Probe Shows Poor Selectivity in Cells.

    Science.gov (United States)

    Hammond, Gerald R V; Takasuga, Shunsuke; Sasaki, Takehiko; Balla, Tamas

    2015-01-01

    Phosphatidylinositol (3,5)-bisphosphate (PtdIns(3,5)P2) is a quantitatively minor phospholipid in eukaryotic cells that plays a fundamental role in regulating endocytic membrane traffic. Despite its clear importance for cellular function and organism physiology, mechanistic details of its biology have so far not been fully elucidated. In part, this is due to a lack of experimental tools that specifically probe for PtdIns(3,5)P2 in cells to unambiguously identify its dynamics and site(s) of action. In this study, we have evaluated a recently reported PtdIns(3,5)P2 biosensor, GFP-ML1Nx2, for its veracity as such a probe. We report that, in live cells, the localization of this biosensor to sub-cellular compartments is largely independent of PtdIns(3,5)P2, as assessed after pharmacological, chemical genetic or genomic interventions that block the lipid's synthesis. We therefore conclude that it is unwise to interpret the localization of ML1Nx2 as a true and unbiased biosensor for PtdIns(3,5)P2.

  15. Optical probe

    International Nuclear Information System (INIS)

    Denis, J.; Decaudin, J.M.

    1984-01-01

    The probe includes optical means of refractive index n, refracting an incident light beam from a medium with a refractive index n1>n and reflecting an incident light beam from a medium with a refractive index n2 [fr

  16. 2-cm versus 4-cm surgical excision margins for primary cutaneous melanoma thicker than 2 mm: a randomised, multicentre trial

    DEFF Research Database (Denmark)

    Gillgren, Peter; Drzewiecki, Krzysztof T; Niin, Marianne

    2011-01-01

    Optimum surgical resection margins for patients with clinical stage IIA-C cutaneous melanoma thicker than 2 mm are controversial. The aim of the study was to test whether survival was different for a wide local excision margin of 2 cm compared with a 4-cm excision margin....

  17. Surgical excision for recurrent herpes simplex virus 2 (HSV-2) anogenital infection in a patient with human immunodeficiency virus (HIV).

    Science.gov (United States)

    Arinze, Folasade; Shaver, Aaron; Raffanti, Stephen

    2017-10-01

    Recurrent anogenital herpes simplex virus infections are common in patients with human immunodeficiency virus (HIV), of whom approximately 5% develop resistance to acyclovir. We present a case of a 49-year-old man with HIV who had an 8-year history of recurrent left inguinal herpes simplex virus type 2 ulcerations. He initially responded to oral acyclovir, but developed resistance to acyclovir and eventually foscarnet. The lesion progressed to a large hypertrophic mass that required surgical excision, which led to resolution without recurrences. Our case highlights the importance of surgical excision as a treatment option in refractory herpes simplex virus anogenital infections.

  18. The role of student surgical interest groups and surgical Olympiads in anatomical and surgical undergraduate training in Russia.

    Science.gov (United States)

    Dydykin, Sergey; Kapitonova, Marina

    2015-01-01

    Traditional department-based surgical interest groups in Russian medical schools are useful tools for student-based selection of specialty training. They also form a nucleus for initiating research activities among undergraduate students. In Russia, the Departments of Topographical Anatomy and Operative Surgery play an important role in initiating student-led research and providing learners with advanced, practical surgical skills. In tandem with department-led activities, student surgical interest groups prepare learners through surgical competitions, known as "Surgical Olympiads," which have been conducted in many Russian centers on a regular basis since 1988. Surgical Olympiads stimulate student interest in the development of surgical skills before graduation and encourage students to choose surgery as their postgraduate specialty. Many of the participants in these surgical Olympiads have become highly qualified specialists in general surgery, orthopedic surgery, neurosurgery, urology, gynecology, and emergency medicine. The present article emphasizes the role of student interest groups and surgical Olympiads in clinical anatomical and surgical undergraduate training in Russia. © 2015 American Association of Anatomists.

  19. Development of transient internal probe (TIP) magnetic field diagnostic

    International Nuclear Information System (INIS)

    Galambos, J.P.; Bohnet, M.A.; Jarboe, T.R.; Mattick, A.T.

    1994-01-01

    The Transient Internal Probe (TIP) is designed to permit measurement of internal magnetic fields, in hot, high density plasmas. The concept consists of accelerating a probe to high velocities (2.2 Km/s) in order to minimize probe exposure time to plasma. Faraday rotation within the probe is used to measure the local magnetic field. An Argon laser illuminates the probe consisting of a Faraday-rotator material with a retro-reflector that returns the incident light to the detection system. Performance results of the light gas gun and optical detection system will be shown. To date, the gas gun has been extensively tested consistently achieving velocities between 2 and 3 km/s. The probe and detection scheme have been tested by dropping the probe through a static magnetic field. Magnetic field resolution of 20 gauss and spatial resolution of 5 mm has been achieved. System frequency response is 10Mhz. Work is currently being conducted to integrate the diagnostic system with laboratory plasma experiments. Specifically a gas interfaced system has been developed to prevent helium muzzle gas from entering the plasma chamber with the probe. Additionally the probe must be separated from the sabot which protects the probe during acceleration in the gas gun. Data will be presented showing the results of various separation techniques

  20. Study of Heterogeneous Structure in Diesel Fuel Spray by Using Micro-Probe L2F

    Science.gov (United States)

    Sakaguchi, Daisaku; Yamamoto, Shohei; Ueki, Hironobu; Ishdia, Masahiro

    A L2F (Laser 2-Focus velocimeter) was applied for the measurements of the velocity and size of droplets in diesel fuel sprays. The micro-scale probe of the L2F has an advantage in avoiding the multiple scattering from droplets in a dense region of fuel sprays. A data sampling rate of 15MHz has been achieved in the L2F system for detecting almost all of the droplets which passed through the measurement probe. Diesel fuel was injected into the atmosphere by using a common rail injector. Measurement positions were located along the spray axis at 10, 15, 20, 25, and 30 mm from the nozzle exit. Measurement result showed that the velocity and size of droplets decreased and the number density of droplets increased along the spray axis. It was clearly shown that the mass flow rate in the spray was highest near the spray tip and was lower inside the spray.

  1. Shared probe design and existing microarray reanalysis using PICKY

    Directory of Open Access Journals (Sweden)

    Chou Hui-Hsien

    2010-04-01

    Full Text Available Abstract Background Large genomes contain families of highly similar genes that cannot be individually identified by microarray probes. This limitation is due to thermodynamic restrictions and cannot be resolved by any computational method. Since gene annotations are updated more frequently than microarrays, another common issue facing microarray users is that existing microarrays must be routinely reanalyzed to determine probes that are still useful with respect to the updated annotations. Results PICKY 2.0 can design shared probes for sets of genes that cannot be individually identified using unique probes. PICKY 2.0 uses novel algorithms to track sharable regions among genes and to strictly distinguish them from other highly similar but nontarget regions during thermodynamic comparisons. Therefore, PICKY does not sacrifice the quality of shared probes when choosing them. The latest PICKY 2.1 includes the new capability to reanalyze existing microarray probes against updated gene sets to determine probes that are still valid to use. In addition, more precise nonlinear salt effect estimates and other improvements are added, making PICKY 2.1 more versatile to microarray users. Conclusions Shared probes allow expressed gene family members to be detected; this capability is generally more desirable than not knowing anything about these genes. Shared probes also enable the design of cross-genome microarrays, which facilitate multiple species identification in environmental samples. The new nonlinear salt effect calculation significantly increases the precision of probes at a lower buffer salt concentration, and the probe reanalysis function improves existing microarray result interpretations.

  2. Electrical and photomechanical effects of plastic deformation of mercuric iodide

    International Nuclear Information System (INIS)

    Marschall, J.; Milstein, F.; Gerrish, V.

    1991-01-01

    The effects of bulk plastic deformation of mercuric iodide (HgI 2 ), upon some of the electronic properties relevant to the performance of HgI 2 as a radiation detector were examined experimentally. Hole lifetimes, as well as hole and electron mobilities, were measured at various stages of sample deformation. Hole lifetimes were found to decrease by a factor of 2 under strains of several percent; carrier mobilities varied within experimental error, except during creep loading where electron and hole mobilities decreased by about 65 % and 25 %, respectively. Additionally, dark current measurements were made on specimens with varying degrees of accumulated plastic damage caused by c plane shear. Dark current values did not strongly reflect the extent of bulk plastic damage in deformed specimens. 16 refs., 4 figs., 1 tab

  3. Pre-surgical register of tobacco consumption.

    Science.gov (United States)

    Gavilán, Eva; Moreno, Montse; Pérez, Àngels; Castellano, Yolanda; Fernández, Esteve; Martínez, Cristina

    2018-03-24

    Smoking cessation before surgery decreases the risk of complications. The aim of this study was to analyse the smoking register, associated variables and a short talk given to smokers in pre-surgical visits. Cross-sectional study. The pre-surgical records of 680 patients were assessed. We selected patient sociodemographic variables, surgical intervention characteristics, smoking status and consumption pattern. Logistic regression was used to study the variables association with smoking. A percentage of 97.2 of the pre-surgical records include information on tobacco consumption. Overall 20% of surgical patients are smokers. The probability of smoking is higher among men (adjusted odds ratio [aOR] 2.6, 95% confidence interval [CI] 1.7-4.0) and≤60 years (aOR 5.4, 95% CI 3.2-9.1). None of the records had information regarding a short talk given to patients to give up smoking. Smoking consumption was prevalent, but the characterisation of a smoker's profile and short talk given to patient before surgery was practically nonexistent. Ensuring that patients who smokes receives a short talk to give up smoking before surgery is necessary. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  4. Improving core surgical training in a major trauma centre.

    Science.gov (United States)

    Morris, Daniel L J; Bryson, David J; Ollivere, Ben J; Forward, Daren P

    2016-06-01

    English Major Trauma Centres (MTCs) were established in April 2012. Increased case volume and complexity has influenced trauma and orthopaedic (T&O) core surgical training in these centres. To determine if T&O core surgical training in MTCs meets Joint Committee on Surgical Training (JCST) quality indicators including performance of T&O operative procedures and consultant supervised session attendance. An audit cycle assessing the impact of a weekly departmental core surgical trainee rota. The rota included allocated timetabled sessions that optimised clinical and surgical learning opportunities. Intercollegiate Surgical Curriculum Programme (ISCP) records for T&O core surgical trainees at a single MTC were analysed for 8 months pre and post rota introduction. Outcome measures were electronic surgical logbook evidence of leading T&O operative procedures and consultant validated work-based assessments (WBAs). Nine core surgical trainees completed a 4 month MTC placement pre and post introduction of the core surgical trainee rota. Introduction of core surgical trainee rota significantly increased the mean number of T&O operative procedures led by a core surgical trainee during a 4 month MTC placement from 20.2 to 34.0 (pcore surgical trainee during a 4 month MTC placement was significantly increased (0.3 vs 2.4 [p=0.04]). Those of dynamic hip screw fixation (2.3 vs 3.6) and ankle fracture fixation (0.7 vs 1.6) were not. Introduction of a core surgical trainee rota significantly increased the mean number of consultant validated WBAs completed by a core surgical trainee during a 4 month MTC placement from 1.7 to 6.6 (pcore surgical trainee rota utilising a 'problem-based' model can significantly improve T&O core surgical training in MTCs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Retained surgical sponge

    International Nuclear Information System (INIS)

    Koyama, Masashi; Kurono, Kenji; Iida, Akihiko; Suzuki, Hirochika; Hara, Masaki; Mizutani, Hirokazu; Ohba, Satoru; Mizutani, Masaru; Nakajima, Yoichiro.

    1993-01-01

    The CT, US, and MRI findings of confirmed retained surgical sponges were reviewed. The CT examinations in eight lesions demonstrated round or oval masses with heterogeneous internal structures. The US examinations in 5 lesions demonstrated low echogenic masses with high echogenic internal structures, which suggested retained surgical sponges. MR imagings in three lesions showed slightly high intensity comparable to that of muscles on T1-weighted images and high signal intensity on T2-weighted images, suggesting fluid collections of high protein concentration. (author)

  6. Multimodal strategies to improve surgical outcome

    DEFF Research Database (Denmark)

    Kehlet, Henrik; Wilmore, Douglas W

    2002-01-01

    OBJECTIVE: To evaluate the effect of modifying perioperative care in noncardiac surgical patients on morbidity, mortality, and other outcome measures. BACKGROUND: New approaches in pain control, introduction of techniques that reduce the perioperative stress response, and the more frequent use...... anesthesia in elective operations, and pilot studies of fast track surgical procedures using the multimodality approach. RESULTS: The introduction of newer approaches to perioperative care has reduced both morbidity and mortality in surgical patients. In the future, most elective operations will become day...... surgical procedures or require only 1 to 2 days of postoperative hospitalization. Reorganization of the perioperative team (anesthesiologists, surgeons, nurses, and physical therapists) will be essential to achieve successful fast track surgical programs. CONCLUSIONS: Understanding perioperative...

  7. Four-probe measurements with a three-probe scanning tunneling microscope

    International Nuclear Information System (INIS)

    Salomons, Mark; Martins, Bruno V. C.; Zikovsky, Janik; Wolkow, Robert A.

    2014-01-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe

  8. Four-probe measurements with a three-probe scanning tunneling microscope

    Energy Technology Data Exchange (ETDEWEB)

    Salomons, Mark [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta T6G 2M9 (Canada); Martins, Bruno V. C.; Zikovsky, Janik; Wolkow, Robert A., E-mail: rwolkow@ualberta.ca [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta T6G 2M9 (Canada); Department of Physics, University of Alberta, Edmonton, Alberta T6G 2E1 (Canada)

    2014-04-15

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  9. Four-probe measurements with a three-probe scanning tunneling microscope.

    Science.gov (United States)

    Salomons, Mark; Martins, Bruno V C; Zikovsky, Janik; Wolkow, Robert A

    2014-04-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  10. Measurement of H2O2 within Living Drosophila during Aging Using a Ratiometric Mass Spectrometry Probe Targeted to the Mitochondrial Matrix

    Science.gov (United States)

    Cochemé, Helena M.; Quin, Caroline; McQuaker, Stephen J.; Cabreiro, Filipe; Logan, Angela; Prime, Tracy A.; Abakumova, Irina; Patel, Jigna V.; Fearnley, Ian M.; James, Andrew M.; Porteous, Carolyn M.; Smith, Robin A.J.; Saeed, Saima; Carré, Jane E.; Singer, Mervyn; Gems, David; Hartley, Richard C.; Partridge, Linda; Murphy, Michael P.

    2011-01-01

    Summary Hydrogen peroxide (H2O2) is central to mitochondrial oxidative damage and redox signaling, but its roles are poorly understood due to the difficulty of measuring mitochondrial H2O2 in vivo. Here we report a ratiometric mass spectrometry probe approach to assess mitochondrial matrix H2O2 levels in vivo. The probe, MitoB, comprises a triphenylphosphonium (TPP) cation driving its accumulation within mitochondria, conjugated to an arylboronic acid that reacts with H2O2 to form a phenol, MitoP. Quantifying the MitoP/MitoB ratio by liquid chromatography-tandem mass spectrometry enabled measurement of a weighted average of mitochondrial H2O2 that predominantly reports on thoracic muscle mitochondria within living flies. There was an increase in mitochondrial H2O2 with age in flies, which was not coordinately altered by interventions that modulated life span. Our findings provide approaches to investigate mitochondrial ROS in vivo and suggest that while an increase in overall mitochondrial H2O2 correlates with aging, it may not be causative. PMID:21356523

  11. Intraoperative use of gamma-detecting probes to localize neuroendocrine tumor

    International Nuclear Information System (INIS)

    Adams, S.; Baum, R.P.

    2000-01-01

    Neuroendocrine tumors are characterized by the expression of different peptides and biogenic amines. These rare tumors tend to grow slowly and are notoriously difficult to localize, at least in the early stages. Surgical removal is the only definitive therapeutic option for neuroendocrine tumors and relief from hyper functional status. The effectiveness of surgical treatment is invariably dependent upon the complete surgical excision of all tumor tissue, because microscopic and occult disease not readily seen by the surgeon may remain in sit, leading to shortened survival. Radio guided surgery (RGS) is an intraoperative technique that enables the surgeon to localize radiolabelled tissue based on the characteristics of the various tissues. For imaging recurrent MTC (Medullary Thyroid Cancer) many radiopharmaceuticals have been used to visualize tumor sites, but none of them has shown excellent sensitivity. Preoperative somatostatin receptor scintigraphy and intraoperative RGS in patients with recurrent MTC demonstrate only part of the tumor sites and cannot visualize small tumor sites (less than 10 mm). In patients with recurrent MTC, intraoperative gamma probe examination is able to localize over 30% more tumor lesions when compared with conventional preoperative imaging modalities and surgical findings. In addition to scintigraphy of the adrenal glands by precursors of adrenal hormones, imaging with a radiolabelled somatostatin analogue is possible; however ( 111 In-DTPA-D-Phe 1 )-pentetreotide is not specific for any adrenal disease or function and the relatively high radioligand accumulation in the kidneys limited the use for detection of tumors in the area of the adrenal glands

  12. Intraoperative use of gamma-detecting probes to localize neuroendocrine tumor

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S. [Johann Wolfgang Goethe Univ., Frankfurt/Main (Germany). Medical Center, Dept. of Nuclear Medicine; Baum, R.P. [Zentralklinik Bad Berka GmbH, Bad Berka (Germany). Clinic of Nuclear Medicine/PET Center

    2000-03-01

    Neuroendocrine tumors are characterized by the expression of different peptides and biogenic amines. These rare tumors tend to grow slowly and are notoriously difficult to localize, at least in the early stages. Surgical removal is the only definitive therapeutic option for neuroendocrine tumors and relief from hyper functional status. The effectiveness of surgical treatment is invariably dependent upon the complete surgical excision of all tumor tissue, because microscopic and occult disease not readily seen by the surgeon may remain in sit, leading to shortened survival. Radio guided surgery (RGS) is an intraoperative technique that enables the surgeon to localize radiolabelled tissue based on the characteristics of the various tissues. For imaging recurrent MTC (Medullary Thyroid Cancer) many radiopharmaceuticals have been used to visualize tumor sites, but none of them has shown excellent sensitivity. Preoperative somatostatin receptor scintigraphy and intraoperative RGS in patients with recurrent MTC demonstrate only part of the tumor sites and cannot visualize small tumor sites (less than 10 mm). In patients with recurrent MTC, intraoperative gamma probe examination is able to localize over 30% more tumor lesions when compared with conventional preoperative imaging modalities and surgical findings. In addition to scintigraphy of the adrenal glands by precursors of adrenal hormones, imaging with a radiolabelled somatostatin analogue is possible; however ({sup 111}In-DTPA-D-Phe{sup 1})-pentetreotide is not specific for any adrenal disease or function and the relatively high radioligand accumulation in the kidneys limited the use for detection of tumors in the area of the adrenal glands.

  13. Photodissociation of 1,2-dibromoethylene at 248 nm: Br2 molecular elimination probed by cavity ring-down absorption spectroscopy.

    Science.gov (United States)

    Chang, Yuan-Pin; Lee, Ping-Chen; Lin, King-Chuen; Huang, C H; Sun, B J; Chang, A H H

    2008-06-02

    The Br2 elimination channel is probed for 1,2-C2H2Br2 in the B(3)Pi(+)ou-X(1)Sigma(+)g transition upon irradiation at 248 nm by using cavity ring-down absorption spectroscopy (CRDS). The nascent vibrational population ratio of Br2(v=1)/Br2(v=0) is obtained to be 0.7+/-0.2, thus indicating that the Br2 fragment is produced in hot vibrational states. The obtained Br2 products are anticipated to result primarily from photodissociation of the ground-state cis isomer via four-center elimination or from cis/trans isomers via three-center elimination, each mechanism involving a transition state that has a Br-Br distance much larger than that of ground state Br2. According to ab initio potential energy calculations, the pathways that lead to Br2 elimination may proceed either through the electronic ground state by internal conversion or through the triplet state by intersystem crossing. Temperature-dependence measurements are examined, thereby supporting the pathway that involves internal conversion--which was excluded previously by using product translational spectroscopy (PTS). The quantum yield for the Br2 elimination reaction is determined to be 0.120.1, being substantially contributed by the ground-state Br2 product. The discrepancy of this value from that (of 0.2) obtained by PTS may rise from the lack of measurements in probing the triplet-state Br2 product.

  14. Surgical versus non-surgical management of abdominal injury.

    Science.gov (United States)

    Oyo-Ita, Angela; Chinnock, Paul; Ikpeme, Ikpeme A

    2015-11-13

    Injury to the abdomen can be blunt or penetrating. Abdominal injury can damage internal organs such as the liver, spleen, kidneys, intestine, and large blood vessels. There are controversies about the best approach to manage abdominal injuries. To assess the effects of surgical and non-surgical interventions in the management of abdominal trauma in a haemodynamically stable and non-peritonitic abdomen. We searched the Cochrane Injuries Group's Specialised Register, The Cochrane Library, Ovid MEDLINE(R), Ovid MEDLINE(R) In-Process & Other Non-Indexed Citations, Ovid MEDLINE(R) Daily and Ovid OLDMEDLINE(R), EMBASE Classic+EMBASE (Ovid), ISI WOS (SCI-EXPANDED, SSCI, CPCI-S & CPSI-SSH), CINAHL Plus (EBSCO), and clinical trials registers, and screened reference lists. We ran the most recent search on 17 September 2015. Randomised controlled trials of surgical interventions and non-surgical interventions involving people with abdominal injury who were haemodynamically stable with no signs of peritonitis. The abdominal injury could be blunt or penetrating. Two review authors independently applied the selection criteria. Data were extracted by two authors using a standard data extraction form, and are reported narratively. Two studies are included, which involved a total of 114 people with penetrating abdominal injuries. Both studies are at moderate risk of bias because the randomisation methods are not fully described, and the original study protocols are no longer available. The studies were undertaken in Finland between 1992 and 2002, by the same two researchers.In one study, 51 people were randomised to surgery or an observation protocol. None of the participants in the study died. Seven people had complications: 5 (18.5%) in the surgical group and 2 (8.3%) in the observation group; the difference was not statistically significant (P = 0.42; Fischer's exact). Among the 27 people who had surgery, 6 (22.2%) surgeries were negative laparotomies, and 15 (55.6%) were non

  15. Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

    Science.gov (United States)

    Zhang, Y. P.; Liu, Yi; Luo, X. B.; Isobe, M.; Yuan, G. L.; Liu, Y. Q.; Hua, Y.; Song, X. Y.; Yang, J. W.; Li, X.; Chen, W.; Li, Y.; Yan, L. W.; Song, X. M.; Yang, Q. W.; Duan, X. R.

    2014-05-01

    A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team, Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported.

  16. Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y. P., E-mail: zhangyp@swip.ac.cn; Liu, Yi; Yuan, G. L.; Song, X. Y.; Yang, J. W.; Li, X.; Chen, W.; Li, Y.; Yan, L. W.; Song, X. M.; Yang, Q. W.; Duan, X. R. [Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041 (China); Luo, X. B.; Liu, Y. Q.; Hua, Y. [Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610041 (China); Isobe, M. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5259 (Japan)

    2014-05-15

    A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team , Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported.

  17. Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

    International Nuclear Information System (INIS)

    Zhang, Y. P.; Liu, Yi; Yuan, G. L.; Song, X. Y.; Yang, J. W.; Li, X.; Chen, W.; Li, Y.; Yan, L. W.; Song, X. M.; Yang, Q. W.; Duan, X. R.; Luo, X. B.; Liu, Y. Q.; Hua, Y.; Isobe, M.

    2014-01-01

    A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team , Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported

  18. Multicolor fluorescent intravital live microscopy (FILM) for surgical tumor resection in a mouse xenograft model.

    Science.gov (United States)

    Thurber, Greg M; Figueiredo, Jose L; Weissleder, Ralph

    2009-11-30

    Complete surgical resection of neoplasia remains one of the most efficient tumor therapies. However, malignant cell clusters are often left behind during surgery due to the inability to visualize and differentiate them against host tissue. Here we establish the feasibility of multicolor fluorescent intravital live microscopy (FILM) where multiple cellular and/or unique tissue compartments are stained simultaneously and imaged in real time. Theoretical simulations of imaging probe localization were carried out for three agents with specificity for cancer cells, stromal host response, or vascular perfusion. This transport analysis gave insight into the probe pharmacokinetics and tissue distribution, facilitating the experimental design and allowing predictions to be made about the localization of the probes in other animal models and in the clinic. The imaging probes were administered systemically at optimal time points based on the simulations, and the multicolor FILM images obtained in vivo were then compared to conventional pathological sections. Our data show the feasibility of real time in vivo pathology at cellular resolution and molecular specificity with excellent agreement between intravital and traditional in vitro immunohistochemistry. Multicolor FILM is an accurate method for identifying malignant tissue and cells in vivo. The imaging probes distributed in a manner similar to predictions based on transport principles, and these models can be used to design future probes and experiments. FILM can provide critical real time feedback and should be a useful tool for more effective and complete cancer resection.

  19. Multicolor fluorescent intravital live microscopy (FILM for surgical tumor resection in a mouse xenograft model.

    Directory of Open Access Journals (Sweden)

    Greg M Thurber

    2009-11-01

    Full Text Available Complete surgical resection of neoplasia remains one of the most efficient tumor therapies. However, malignant cell clusters are often left behind during surgery due to the inability to visualize and differentiate them against host tissue. Here we establish the feasibility of multicolor fluorescent intravital live microscopy (FILM where multiple cellular and/or unique tissue compartments are stained simultaneously and imaged in real time.Theoretical simulations of imaging probe localization were carried out for three agents with specificity for cancer cells, stromal host response, or vascular perfusion. This transport analysis gave insight into the probe pharmacokinetics and tissue distribution, facilitating the experimental design and allowing predictions to be made about the localization of the probes in other animal models and in the clinic. The imaging probes were administered systemically at optimal time points based on the simulations, and the multicolor FILM images obtained in vivo were then compared to conventional pathological sections. Our data show the feasibility of real time in vivo pathology at cellular resolution and molecular specificity with excellent agreement between intravital and traditional in vitro immunohistochemistry.Multicolor FILM is an accurate method for identifying malignant tissue and cells in vivo. The imaging probes distributed in a manner similar to predictions based on transport principles, and these models can be used to design future probes and experiments. FILM can provide critical real time feedback and should be a useful tool for more effective and complete cancer resection.

  20. Wrong-Site Surgery, Retained Surgical Items, and Surgical Fires : A Systematic Review of Surgical Never Events.

    Science.gov (United States)

    Hempel, Susanne; Maggard-Gibbons, Melinda; Nguyen, David K; Dawes, Aaron J; Miake-Lye, Isomi; Beroes, Jessica M; Booth, Marika J; Miles, Jeremy N V; Shanman, Roberta; Shekelle, Paul G

    2015-08-01

    Serious, preventable surgical events, termed never events, continue to occur despite considerable patient safety efforts. To examine the incidence and root causes of and interventions to prevent wrong-site surgery, retained surgical items, and surgical fires in the era after the implementation of the Universal Protocol in 2004. We searched 9 electronic databases for entries from 2004 through June 30, 2014, screened references, and consulted experts. Two independent reviewers identified relevant publications in June 2014. One reviewer used a standardized form to extract data and a second reviewer checked the data. Strength of evidence was established by the review team. Data extraction was completed in January 2015. Incidence of wrong-site surgery, retained surgical items, and surgical fires. We found 138 empirical studies that met our inclusion criteria. Incidence estimates for wrong-site surgery in US settings varied by data source and procedure (median estimate, 0.09 events per 10,000 surgical procedures). The median estimate for retained surgical items was 1.32 events per 10,000 procedures, but estimates varied by item and procedure. The per-procedure surgical fire incidence is unknown. A frequently reported root cause was inadequate communication. Methodologic challenges associated with investigating changes in rare events limit the conclusions of 78 intervention evaluations. Limited evidence supported the Universal Protocol (5 studies), education (4 studies), and team training (4 studies) interventions to prevent wrong-site surgery. Limited evidence exists to prevent retained surgical items by using data-matrix-coded sponge-counting systems (5 pertinent studies). Evidence for preventing surgical fires was insufficient, and intervention effects were not estimable. Current estimates for wrong-site surgery and retained surgical items are 1 event per 100,000 and 1 event per 10,000 procedures, respectively, but the precision is uncertain, and the per

  1. IVVS probe mechanical concept design

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo, E-mail: paolo.rossi@enea.it; Neri, Carlo; De Collibus, Mario Ferri; Mugnaini, Giampiero; Pollastrone, Fabio; Crescenzi, Fabio

    2015-10-15

    Highlights: • ENEA designed, developed and tested a laser based In Vessel Viewing System (IVVS). • IVVS mechanical design has been revised from 2011 to 2013 to meet ITER requirements. • Main improvements are piezoceramic actuators and a step focus system. • Successful qualification activities validated the concept design for ITER environment. - Abstract: ENEA has been deeply involved in the design, development and testing of a laser based In Vessel Viewing System (IVVS) required for the inspection of ITER plasma-facing components. The IVVS probe shall be deployed into the vacuum vessel, providing high resolution images and metrology measurements to detect damages and possible erosion. ENEA already designed and manufactured an IVVS probe prototype based on a rad-hard concept and driven by commercial micro-step motors, which demonstrated satisfying viewing and metrology performances at room conditions. The probe sends a laser beam through a reflective rotating prism. By rotating the axes of the prism, the probe can scan all the environment points except those present in a shadow cone and the backscattered light signal is then processed to measure the intensity level (viewing) and the distance from the probe (metrology). During the last years, in order to meet all the ITER environmental conditions, such as high vacuum, gamma radiation lifetime dose up to 5 MGy, cumulative neutron fluence of about 2.3 × 10{sup 17} n/cm{sup 2}, temperature of 120 °C and magnetic field of 8 T, the probe mechanical design was significantly revised introducing a new actuating system based on piezo-ceramic actuators and improved with a new step focus system. The optical and mechanical schemes have been then modified and refined to meet also the geometrical constraints. The paper describes the mechanical concept design solutions adopted in order to fulfill IVVS probe functional performance requirements considering ITER working environment and geometrical constraints.

  2. Multimodal fiber-probe spectroscopy as a clinical tool for diagnosing and classifying biological tissues

    Science.gov (United States)

    Cicchi, Riccardo; Anand, Suresh; Fantechi, Riccardo; Giordano, Flavio; Gacci, Mauro; Conti, Valerio; Nesi, Gabriella; Buccoliero, Anna Maria; Carini, Marco; Guerrini, Renzo; Pavone, Francesco Saverio

    2017-07-01

    An optical fiber probe for multimodal spectroscopy was designed, developed and used for tissue diagnostics. The probe, based on a fiber bundle with optical fibers of various size and properties, allows performing spectroscopic measurements with different techniques, including fluorescence, Raman, and diffuse reflectance, using the same probe. Two visible laser diodes were used for fluorescence spectroscopy, a laser diode emitting in the NIR was used for Raman spectroscopy, and a fiber-coupled halogen lamp for diffuse reflectance. The developed probe was successfully employed for diagnostic purposes on various tissues, including brain and bladder. In particular, the device allowed discriminating healthy tissue from both tumor and dysplastic tissue as well as to perform tumor grading. The diagnostic capabilities of the method, determined using a cross-validation method with a leave-one-out approach, demonstrated high sensitivity and specificity for all the examined samples, as well as a good agreement with histopathological examination performed on the same samples. The obtained results demonstrated that the multimodal approach is crucial for improving diagnostic capabilities with respect to what can be obtained from individual techniques. The experimental setup presented here can improve diagnostic capabilities on a broad range of tissues and has the potential of being used clinically for guiding surgical resection in the near future.

  3. Mobile Game Probes

    DEFF Research Database (Denmark)

    Borup Lynggaard, Aviaja

    2006-01-01

    This paper will examine how probes can be useful for game designers in the preliminary phases of a design process. The work is based upon a case study concerning pervasive mobile phone games where Mobile Game Probes have emerged from the project. The new probes are aimed towards a specific target...... group and the goal is to specify the probes so they will cover the most relevant areas for our project. The Mobile Game Probes generated many interesting results and new issues occurred, since the probes came to be dynamic and favorable for the process in new ways....

  4. Surgical Instrument Sets for Special Operations Expeditionary Surgical Teams.

    Science.gov (United States)

    Hale, Diane F; Sexton, Justin C; Benavides, Linda C; Benavides, Jerry M; Lundy, Jonathan B

    The deployment of surgical assets has been driven by mission demands throughout years of military operations in Iraq and Afghanistan. The transition to the highly expeditious Golden Hour Offset Surgical Transport Team (GHOST- T) now offers highly mobile surgical assets in nontraditional operating rooms; the content of the surgical instrument sets has also transformed to accommodate this change. The 102nd Forward Surgical Team (FST) was attached to Special Operations assigned to southern Afghanistan from June 2015 to March 2016. The focus was to decrease overall size and weight of FST instrument sets without decreasing surgical capability of the GHOST-T. Each instrument set was evaluated and modified to include essential instruments to perform damage control surgery. The overall number of main instrument sets was decreased from eight to four; simplified augmentation sets have been added, which expand the capabilities of any main set. The overall size was decreased by 40% and overall weight decreased by 58%. The cardiothoracic, thoracotomy, and emergency thoracotomy trays were condensed to thoracic set. The orthopedic and amputation sets were replaced with an augmentation set of a prepackaged orthopedic external fixator set). An augmentation set to the major or minor basic sets, specifically for vascular injuries, was created. Through the reorganization of conventional FST surgical instrument sets to maintain damage control capabilities and mobility, the 102nd GHOST-T reduced surgical equipment volume and weight, providing a lesson learned for future surgical teams operating in austere environments. 2017.

  5. Quality control devices for intraoperative gamma probes: physical, technical and radiation protection aspects

    International Nuclear Information System (INIS)

    Varela, C.; Diaz, M.; Salvador, F.J.; Hernandez, M.; Jimenez, P.

    2008-01-01

    Now a day, radio guided surgery -a novelty in Nuclear Medicine- is increasingly used. The clinical efficiency of these procedures requires the existence of well-trained professionals and implementation of quality assurance programs. It is essential for achieving the main objective, which is an effective and safe surgical procedure, a reliable performance of the detection device. Probes' parameters must remain within the acceptance limits, so they should be checked periodically. NEMA Standards Publication NU 3-2004 'Performance Measurement and Quality Control Guidelines for Non-Imaging Intraoperative Gamma Probes' recommends 13 tests; although only 3 of them -sensibility in air, visual inspection and power source check- are considered as steadiness tests. Space resolution in a scatter medium is also a test that needs to be carried out. These tests are considerably complex since open radioactive sources are used into a liquid medium in most of the procedures. The immersion of the probe and of the radioactive sources in each case represents both risks of radioactive contamination, and of damages to the equipment. On the other hand, tests in air demand a good reproducibility. Since they are recommended be carried out before any surgery procedure, they also should be easy and quick. This paper presents 3 devices with its accessories for acceptance and quality control tests of intraoperative gamma probes. They were designed and built taking into consideration important aspects of radiological protection to handle the calibration sources and probes, both in air and into a scatter medium. These devices are designed to fit any kind of probe. Regulatory bodies as part of their instrument audits can also use them. (author)

  6. Intrauterine photoacoustic and ultrasound imaging probe

    Science.gov (United States)

    Miranda, Christopher; Barkley, Joel; Smith, Barbara S.

    2018-04-01

    Intrauterine photoacoustic and ultrasound imaging are probe-based imaging modalities with translational potential for use in detecting endometrial diseases. This deep-tissue imaging probe design allows for the retrofitting of commercially available endometrial sampling curettes. The imaging probe presented here has a 2.92-mm diameter and approximate length of 26 cm, which allows for entry into the human endometrial cavity, making it possible to use photoacoustic imaging and high-resolution ultrasound to characterize the uterus. We demonstrate the imaging probes' ability to provide structural information of an excised pig uterus using ultrasound imaging and detect photoacoustic signals at a radial depth of 1 cm.

  7. Surgical history of ancient China: Part 2.

    Science.gov (United States)

    Fu, Louis

    2010-03-01

    In this second part of ancient Chinese surgical history, the practice of bone setting in China began around 3000 years ago. Throughout this period, significant progress was made, some highlights of which are cited. These methods, comparable with Western orthopaedic technique, are still being practised today. In conclusion, the possible reasons for the lack of advancement in operative surgery are discussed, within context of the cultural, social and religious background of ancient China.

  8. Objective, Quantitative, Data-Driven Assessment of Chemical Probes.

    Science.gov (United States)

    Antolin, Albert A; Tym, Joseph E; Komianou, Angeliki; Collins, Ian; Workman, Paul; Al-Lazikani, Bissan

    2018-02-15

    Chemical probes are essential tools for understanding biological systems and for target validation, yet selecting probes for biomedical research is rarely based on objective assessment of all potential compounds. Here, we describe the Probe Miner: Chemical Probes Objective Assessment resource, capitalizing on the plethora of public medicinal chemistry data to empower quantitative, objective, data-driven evaluation of chemical probes. We assess >1.8 million compounds for their suitability as chemical tools against 2,220 human targets and dissect the biases and limitations encountered. Probe Miner represents a valuable resource to aid the identification of potential chemical probes, particularly when used alongside expert curation. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Short recovery time NMR probe

    International Nuclear Information System (INIS)

    Ramia, M.E.; Martin, C.A.; Jeandrevin, S.

    2011-01-01

    A NMR probe for low frequency and short recovery time is presented in this work. The probe contains the tuning circuit, diode expanders and quarter wavelength networks to protect the receiver from both the amplifier noise and the coil ringing following the transmitter power pulse. It also possesses a coil damper which is activated by of non active components. The probe performance shows a recovery time of about of 15μs a sensitive Q factor reduction and an increase of the signal to noise ratio of about 68% during the reception at a work frequency of 2 MHz. (author)

  10. Traversing probe system

    Science.gov (United States)

    Mashburn, Douglas N.; Stevens, Richard H.; Woodall, Harold C.

    1977-01-01

    This invention comprises a rotatable annular probe-positioner which carries at least one radially disposed sensing probe, such as a Pitot tube having a right-angled tip. The positioner can be coaxially and rotatably mounted within a compressor casing or the like and then actuated to orient the sensing probe as required to make measurements at selected stations in the annulus between the positioner and compressor casing. The positioner can be actuated to (a) selectively move the probe along its own axis, (b) adjust the yaw angle of the right-angled probe tip, and (c) revolve the probe about the axis common to the positioner and casing. A cam plate engages a cam-follower portion of the probe and normally rotates with the positioner. The positioner includes a first-motor-driven ring gear which effects slidable movement of the probe by rotating the positioner at a time when an external pneumatic cylinder is actuated to engage the cam plate and hold it stationary. When the pneumatic cylinder is not actuated, this ring gear can be driven to revolve the positioner and thus the probe to a desired circumferential location about the above-mentioned common axis. A second motor-driven ring gear included in the positioner can be driven to rotate the probe about its axis, thus adjusting the yaw angle of the probe tip. The positioner can be used in highly corrosive atmosphere, such as gaseous uranium hexafluoride.

  11. Traversing probe system

    International Nuclear Information System (INIS)

    Mashburn, D.N.; Stevens, R.H.; Woodall, H.C.

    1977-01-01

    This invention comprises a rotatable annular probe-positioner which carries at least one radially disposed sensing probe, such as a Pitot tube having a right-angled tip. The positioner can be coaxially and rotatably mounted within a compressor casing or the like and then actuated to orient the sensing probe as required to make measurements at selected stations in the annulus between the positioner and compressor casing. The positioner can be actuated to (a) selectively move the probe along its own axis, (b) adjust the yaw angle of the right-angled probe tip, and (c) revolve the probe about the axis common to the positioner and casing. A cam plate engages a cam-follower portion of the probe and normally rotates with the positioner. The positioner includes a first-motor-driven ring gear which effects slidable movement of the probe by rotating the positioner at a time when an external pneumatic cylinder is actuated to engage the cam plate and hold it stationary. When the pneumatic cylinder is not actuated, this ring gear can be driven to revolve the positioner and thus the probe to a desired circumferential location about the above-mentioned common axis. A second motor-driven ring gear included in the positioner can be driven to rotate the probe about its axis, thus adjusting the yaw angle of the probe tip. The positioner can be used in highly corrosive atmosphere, such as gaseous uranium hexafluoride. 10 claims, 6 figures

  12. Surgical complications in 2,840 cases of hemorrhoidectomy by Milligan-Morgan, Ferguson and combined techniques

    Directory of Open Access Journals (Sweden)

    Guilherme de Almeida Santos

    2012-09-01

    Full Text Available The analysis of 2,840 cases of hemorrhoidectomy by open techniques of Milligan-Morgan (2,189 cases, Ferguson (341 cases and mixed (310 cases in 11,043 patients with hemorrhoidal disease (HD allowed the following conclusions. The patients' acceptance of surgical indication for hemorrhoidectomy was 25.7%. Hemorrhoidectomy was more common among women (53.8% than men (46.2%, and more accepted by women (26.5% than men (24.8%. Hemorrhoidectomy was more common in patients of the fourth (27.7%, fifth (21.9% and third (21.0% decades of age. Most patients who agreed to undergo hemorrhoidectomy were those of the second (38.2%, eighth (35.9% and ninth (34.5% decades of age. The overall incidence of surgical complications was 3.0% (87 cases: anal stenosis (1.8%, bleeding (0.8%, worsening of anal hypotonia (0.2%, sepsis (0.1% and systemic complications (0.1%, with no difference among the techniques used. The incidence of surgical complications by Milligan-Morgan technique was 3.0% - stenosis (1.9%, bleeding (1.9%, worsening of anal hypotonia (0.2% and systemic complications (0.04%. The incidence of surgical complications by Ferguson's technique was 3.5% - stenosis (1.7%, bleeding (0.6%, worsening of anal hypotonia (0.6% and sepsis (0.6%. And the incidence of surgical complications by mixed techniques was 2.5% - stenosis (1.0%, bleeding (0.3%, worsening of anal hypotonia (0.3%, sepsis (0.3% and systemic complications (0.3%. The incidence of surgical complications according to gender was 3.0% among women and 3.2% among men, with higher incidence of stenosis in women (2.0% and hemorrhage in men (1.1%. Surgical complications were more observed in the eighth (5.1% and seventh (3.8% decades of age. The incidence of anal stenosis was 1.8%, being 64.0% without hypotonia and 66.0% without anal fissure (66.0%, with annular stenosis as the most common anatomical shape (70.0%. Anal stenosis was more common among women (2.0% presenting mean age of 38.2 years, with no

  13. Influence of probe geometry on the response of an electrostatic probe

    DEFF Research Database (Denmark)

    Johansson, Torben; Crichton, George C; McAllister, Iain Wilson

    1999-01-01

    The response of an electrostatic probe is examined with reference to the probe geometry. The study involves the evaluation of the probe lambda function, from which response-related characteristic parameters can be derived. These parameters enable the probe detection sensitivity Se and spatial...

  14. Surgical site infections in an abdominal surgical ward at Kosovo Teaching Hospital.

    Science.gov (United States)

    Raka, Lul; Krasniqi, Avdyl; Hoxha, Faton; Musa, Ruustem; Mulliqi, Gjyle; Krasniqi, Selvete; Kurti, Arsim; Dervishaj, Antigona; Nuhiu, Beqir; Kelmendi, Baton; Limani, Dalip; Tolaj, Ilir

    2008-01-01

    Abdominal surgical site infections (SSI) cause substantial morbidity and mortality for patients undergoing operative procedures. We determined the incidence of and risk factors for SSI after abdominal surgery in the Department of Abdominal Surgery at the University Clinical Centre of Kosovo (UCCK). Prospective surveillance of patients undergoing abdominal surgery was performed between December 2005 and June 2006. CDC definitions were followed to detect SSI and study forms were based on Europe Link for Infection Control through Surveillance (HELICS) protocol. A total of 253 surgical interventions in 225 patients were evaluated. The median age of patients was 42 years and 55.1% of them were male. The overall incidence rate of SSI was 12%. Follow-up was achieved for 84.1% of the procedures. For patients with an SSI, the median duration of hospitalization was 9 days compared with 4 days for those without an SSI (p 2, use of antibiotic prophylaxis and NNIS class of > 2 were all significant at p < .001. The SSI rates for the NNIS System risk classes 0, 1 and 2-3 were 4.2%, 46.7% and 100%, respectively. SSI caused considerable morbidity among surgical patients in UCCK. Appropriate active surveillance and infection control measures should be introduced during preoperative, intra-operative, and postoperative care to reduce infection rates.

  15. Use of thick HgI2 detectors as intelligent spectrometers

    International Nuclear Information System (INIS)

    Olmos, P.; Garcia-Belmonte, G.; Perez, J.M.; Diaz, J.C.

    1990-01-01

    Mercuric iodide is a very attractive material to detect ionizing radiation due to its high stopping power and wide energy gap, which allows the use of a small and compact detector at room temperature. However, the spectroscopic performances of these detectors are poor in comparisons with other more popular semiconductors with better transport characteristics. This effect becomes dramatic when thick crystals are used. The partial charge-collection method is reported to be the most suitable one for enhancing the energy resolution achieved with thick detectors. A Monte Carlo simulation of the behavior of the model and its dependence with crystals and electronic parameters is presented, giving operating rules that optimize the system performance in each situation. Specially designed hardware has been developed to extract the maximum information of the charge pulse produced by photon-detector interaction, according with the results of the simulation. As a final step, an automatic isotope-identification process, based on the use of neutral networks, is performed, the identification being the true output of the whole system. Due to the strong dependence of this output on the free hardware parameters, an adaptive network is designed to act on these parameters in such a way that the system converges automatically to the best identification. (orig.)

  16. Irradiation probe and laboratory for irradiated material evaluation

    International Nuclear Information System (INIS)

    Smutny, S.; Kupca, L.; Beno, P.; Stubna, M.; Mrva, V.; Chmelo, P.

    1975-09-01

    The survey and assessment are given of the tasks carried out in the years 1971 to 1975 within the development of methods for structural materials irradiation and of a probe for the irradiation thereof in the A-1 reactor. The programme and implementation of laboratory tests of the irradiation probe are described. In the actual reactor irradiation, the pulse tube length between the pressure governor and the irradiation probe is approximately 20 m, the diameter is 2.2 mm. Temperature reaches 800 degC while the pressure control system operates at 20 degC. The laboratory tests (carried out at 20 degC) showed that the response time of the pressure control system to a stepwise pressure change in the irradiation probe from 0 to 22 at. is 0.5 s. Pressure changes were also studied in the irradiation probe and in the entire system resulting from temperature changes in the irradiation probe. Temperature distribution in the body of the irradiation probe heating furnace was determined. (B.S.)

  17. Surgical orthodontics.

    Science.gov (United States)

    Strohl, Alexis M; Vitkus, Lauren

    2017-08-01

    The article reviews some commonly used orthodontic treatments as well as new strategies to assist in the correction of malocclusion. Many techniques are used in conjunction with surgical intervention and are a necessary compliment to orthognathic surgery. Basic knowledge of these practices will aid in the surgeon's ability to adequately treat the patient. Many orthodontists and surgeons are eliminating presurgical orthodontics to adopt a strategy of 'surgery first' orthodontics in orthognathic surgery. This has the benefit of immediate improvement in facial aesthetics and shorter treatment times. The advent of virtual surgical planning has helped facilitate the development of this new paradigm by making surgical planning faster and easier. Furthermore, using intraoperative surgical navigation is improving overall precision and outcomes. A variety of surgical and nonsurgical treatments may be employed in the treatment of malocclusion. It is important to be familiar with all options available and tailor the patient's treatment plan accordingly. Surgery-first orthodontics, intraoperative surgical navigation, virtual surgical planning, and 3D printing are evolving new techniques that are producing shorter treatment times and subsequently improving patient satisfaction without sacrificing long-term stability.

  18. The Oxford Probe: an open access five-hole probe for aerodynamic measurements

    Science.gov (United States)

    Hall, B. F.; Povey, T.

    2017-03-01

    The Oxford Probe is an open access five-hole probe designed for experimental aerodynamic measurements. The open access probe can be manufactured by the end user via additive manufacturing (metal or plastic). The probe geometry, drawings, calibration maps, and software are available under a creative commons license. The purpose is to widen access to aerodynamic measurement techniques in education and research environments. There are many situations in which the open access probe will allow results of comparable accuracy to a well-calibrated commercial probe. We discuss the applications and limitations of the probe, and compare the calibration maps for 16 probes manufactured in different materials and at different scales, but with the same geometrical design.

  19. The Oxford Probe: an open access five-hole probe for aerodynamic measurements

    International Nuclear Information System (INIS)

    Hall, B F; Povey, T

    2017-01-01

    The Oxford Probe is an open access five-hole probe designed for experimental aerodynamic measurements. The open access probe can be manufactured by the end user via additive manufacturing (metal or plastic). The probe geometry, drawings, calibration maps, and software are available under a creative commons license. The purpose is to widen access to aerodynamic measurement techniques in education and research environments. There are many situations in which the open access probe will allow results of comparable accuracy to a well-calibrated commercial probe. We discuss the applications and limitations of the probe, and compare the calibration maps for 16 probes manufactured in different materials and at different scales, but with the same geometrical design. (paper)

  20. TriPer, an optical probe tuned to the endoplasmic reticulum tracks changes in luminal H2O2.

    Science.gov (United States)

    Melo, Eduardo Pinho; Lopes, Carlos; Gollwitzer, Peter; Lortz, Stephan; Lenzen, Sigurd; Mehmeti, Ilir; Kaminski, Clemens F; Ron, David; Avezov, Edward

    2017-03-27

    The fate of hydrogen peroxide (H 2 O 2 ) in the endoplasmic reticulum (ER) has been inferred indirectly from the activity of ER-localized thiol oxidases and peroxiredoxins, in vitro, and the consequences of their genetic manipulation, in vivo. Over the years hints have suggested that glutathione, puzzlingly abundant in the ER lumen, might have a role in reducing the heavy burden of H 2 O 2 produced by the luminal enzymatic machinery for disulfide bond formation. However, limitations in existing organelle-targeted H 2 O 2 probes have rendered them inert in the thiol-oxidizing ER, precluding experimental follow-up of glutathione's role in ER H 2 O 2 metabolism. Here we report on the development of TriPer, a vital optical probe sensitive to changes in the concentration of H 2 O 2 in the thiol-oxidizing environment of the ER. Consistent with the hypothesized contribution of oxidative protein folding to H 2 O 2 production, ER-localized TriPer detected an increase in the luminal H 2 O 2 signal upon induction of pro-insulin (a disulfide-bonded protein of pancreatic β-cells), which was attenuated by the ectopic expression of catalase in the ER lumen. Interfering with glutathione production in the cytosol by buthionine sulfoximine (BSO) or enhancing its localized destruction by expression of the glutathione-degrading enzyme ChaC1 in the lumen of the ER further enhanced the luminal H 2 O 2 signal and eroded β-cell viability. A tri-cysteine system with a single peroxidatic thiol enables H 2 O 2 detection in oxidizing milieux such as that of the ER. Tracking ER H 2 O 2 in live pancreatic β-cells points to a role for glutathione in H 2 O 2 turnover.

  1. A new method for intraoperative localization of epilepsy focus by means of a gamma probe; Um novo metodo para a localizacao intraoperatoria de foco de epilepsia mediante utilizacao de gamaprobe

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro Filho, Omar, E-mail: dromarcarneiro@gmail.com [Centro Brasileiro de Medicina Nuclear e Imagem Molecular (CEBRAMEN), Goiania, GO (Brazil); Instituto de Medicina Nuclear, Goiania, GO (Brazil); Vilela Filho, Osvaldo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Hospital das Clinicas. Servico de Neurocirurgia; Ragazzo, Paulo Cesar [Instituto de Neurologia de Goiania, GO (Brazil). Servico de Eplepsia e Neurofisiologia; Fonseca, Lea Mirian Barbosa da [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Radiologia

    2014-01-15

    Objective: to evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and methods: two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results: in patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion: the comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy. (author)

  2. Probe Techniques. Introductory Remarks

    Energy Technology Data Exchange (ETDEWEB)

    Emeleus, K. G. [School of Physics and Applied Mathematics, Queen' s University, Belfast (United Kingdom)

    1968-04-15

    In this brief introduction to the session on probes, the history of theii development is first touched on briefly. Reference is then made to the significance of the work to be described by Medicus, for conductivity and recombination calculations, and by Lam and Su, for a wide range of medium and higher pressure plasmas. Finally, a number of other probe topics are mentioned, including multiple probes; probes in electronegative plasmas; resonance probes; probes in noisy discharges; probes as oscillation detectors; use of probes where space-charge is not negligible. (author)

  3. Probe-diverse ptychography

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, I., E-mail: isaac.russellpeterson@rmit.edu.au [ARC Centre of Excellence for Coherent X-ray Science, the University of Melbourne, School of Physics, Victoria 3010 (Australia); Harder, R. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Robinson, I.K. [Research Complex at Harwell, Didcot, Oxfordshire OX11 0DE (United Kingdom); London Centre for Nanotechnology, University College London, London WC1H 0AH (United Kingdom)

    2016-12-15

    We propose an extension of ptychography where the target sample is scanned separately through several probes with distinct amplitude and phase profiles and a diffraction image is recorded for each probe and each sample translation. The resulting probe-diverse dataset is used to iteratively retrieve high-resolution images of the sample and all probes simultaneously. The method is shown to yield significant improvement in the reconstructed sample image compared to the image obtained using the standard single-probe ptychographic phase-retrieval scheme.

  4. Assessment of the LV-C2 Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Antonio, Ernest J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-01

    This document reports on a series of tests conducted to assess the proposed air sampling location for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) C2V (LV-C2) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The tests were conducted on the LV-C2 scale model system. Based on the scale model tests, the location proposed for the air sampling probe in the scale model stack meets the requirements of the ANSI/HPS N13.1-1999 standard for velocity uniformity, flow angle, gas tracer and particle tracer uniformity. Additional velocity uniformity and flow angle tests on the actual stack will be necessary during cold startup to confirm the validity of the scale model results in representing the actual stack.

  5. PET Probe-Guided Surgery in Patients with Breast Cancer: Proposal for a Methodological Approach

    Science.gov (United States)

    ORSARIA, PAOLO; CHIARAVALLOTI, AGOSTINO; FIORENTINI, ALESSANDRO; PISTOLESE, CHIARA; VANNI, GIANLUCA; VITTORIA GRANAI, ALESSANDRA; VARVARAS, DIMITRIOS; DANIELI, ROBERTA; SCHILLACI, ORAZIO; PETRELLA, GIUSEPPE; CLAUDIO BUONOMO, ORESTE

    2017-01-01

    Background: Although it is valuable for detecting distant metastases, identifying recurrence, and evaluating responses to chemotherapy, the role of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in assessing locoregional nodal status for initial staging of breast cancer has not yet been well-defined in clinical practice. In the current report, we describe a new PET probe-based clinical approach, with evaluation of the technical performance of a handheld high-energy gamma probe for intraoperative localization of breast carcinomas, and evaluation of lymph node metastases during radio-guided oncological surgery. Patients and Methods: Three patients underwent a PET/CT scan immediately prior to surgery following the standard clinical protocol. Intraoperatively, tumors were localized and resected with the assistance of a hand-held gamma probe. PET-guided assessment of the presence or absence of regional nodal spread of malignancy was compared with the reference standard of histopathological examination. Results: In all three cases, perioperative 18F-FDG PET/CT imaging and intraoperative gamma probe detection verified complete resection of the hypermetabolic lesions and demonstrated no additional suspicious occult disease. Conclusion: This innovative approach demonstrates great promise for providing real-time access to metabolic and morphological tumor information that may lead to an optimal disease-tailored approach. In carefully selected indications, a PET probe can be a useful adjunct in surgical practice, but further trials with a larger number of patients need to be performed to verify these findings. PMID:28064227

  6. Surgical Space Suits Increase Particle and Microbiological Emission Rates in a Simulated Surgical Environment.

    Science.gov (United States)

    Vijaysegaran, Praveen; Knibbs, Luke D; Morawska, Lidia; Crawford, Ross W

    2018-05-01

    The role of space suits in the prevention of orthopedic prosthetic joint infection remains unclear. Recent evidence suggests that space suits may in fact contribute to increased infection rates, with bioaerosol emissions from space suits identified as a potential cause. This study aimed to compare the particle and microbiological emission rates (PER and MER) of space suits and standard surgical clothing. A comparison of emission rates between space suits and standard surgical clothing was performed in a simulated surgical environment during 5 separate experiments. Particle counts were analyzed with 2 separate particle counters capable of detecting particles between 0.1 and 20 μm. An Andersen impactor was used to sample bacteria, with culture counts performed at 24 and 48 hours. Four experiments consistently showed statistically significant increases in both PER and MER when space suits are used compared with standard surgical clothing. One experiment showed inconsistent results, with a trend toward increases in both PER and MER when space suits are used compared with standard surgical clothing. Space suits cause increased PER and MER compared with standard surgical clothing. This finding provides mechanistic evidence to support the increased prosthetic joint infection rates observed in clinical studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Self-leveling 2D DPN probe arrays

    Science.gov (United States)

    Haaheim, Jason R.; Val, Vadim; Solheim, Ed; Bussan, John; Fragala, J.; Nelson, Mike

    2010-02-01

    Dip Pen Nanolithography® (DPN®) is a direct write scanning probe-based technique which operates under ambient conditions, making it suitable to deposit a wide range of biological and inorganic materials. Precision nanoscale deposition is a fundamental requirement to advance nanoscale technology in commercial applications, and tailoring chemical composition and surface structure on the sub-100 nm scale benefits researchers in areas ranging from cell adhesion to cell-signaling and biomimetic membranes. These capabilities naturally suggest a "Desktop Nanofab" concept - a turnkey system that allows a non-expert user to rapidly create high resolution, scalable nanostructures drawing upon well-characterized ink and substrate pairings. In turn, this system is fundamentally supported by a portfolio of MEMS devices tailored for microfluidic ink delivery, directed placement of nanoscale materials, and cm2 tip arrays for high-throughput nanofabrication. Massively parallel two-dimensional nanopatterning is now commercially available via NanoInk's 2D nano PrintArray™, making DPN a high-throughput (>3×107 μm2 per hour), flexible and versatile method for precision nanoscale pattern formation. However, cm2 arrays of nanoscopic tips introduce the nontrivial problem of getting them all evenly touching the surface to ensure homogeneous deposition; this requires extremely precise leveling of the array. Herein, we describe how we have made the process simple by way of a selfleveling gimbal attachment, coupled with semi-automated software leveling routines which bring the cm^2 chip to within 0.002 degrees of co-planarity. This excellent co-planarity yields highly homogeneous features across a square centimeter, with <6% feature size standard deviation. We have engineered the devices to be easy to use, wire-free, and fully integrated with both of our patterning tools: the DPN 5000, and the NLP 2000.

  8. Flexible SiO2 cantilevers for torsional self-aligning micro scale four-point probes

    DEFF Research Database (Denmark)

    Kjær, Daniel; Gammelgaard, Lauge; Bøggild, Peter

    2007-01-01

    In order to successfully measure the conductivity of a sample with a four- point probe, good alignment of the electrodes to the sample is important to establish even contact pressure and contact areas of the electrodes. By incorporating a hinge in a microfabricated SiO2 mono- cantilever the ability...

  9. Surgical fiducial segmentation and tracking for pose estimation based on ultrasound B-mode images.

    Science.gov (United States)

    Lei Chen; Kuo, Nathanael; Aalamifar, Fereshteh; Narrow, David; Coon, Devin; Prince, Jerry; Boctor, Emad M

    2016-08-01

    Doppler ultrasound is a non-invasive diagnostic tool for the quantitative measurement of blood flow. However, given that it provides velocity data that is dependent on the location and angle of measurement, repeat measurements to detect problems over time may require an expert to return to the same location. We therefore developed an image-guidance system based on ultrasound B-mode images that enables an inexperienced user to position the ultrasound probe at the same site repeatedly in order to acquire a comparable time series of Doppler readings. The system utilizes a bioresorbable fiducial and complementing software composed of the fiducial detection, key points tracking, probe pose estimation, and graphical user interface (GUI) modules. The fiducial is an echogenic marker that is implanted at the surgical site and can be detected and tracked during ultrasound B-mode screening. The key points on the marker can next be used to determine the pose of the ultrasound probe with respect to the marker. The 3D representation of the probe with its position and orientation are then displayed in the GUI for the user guidance. The fiducial detection has been tested on the data sets collected from three animal studies. The pose estimation algorithm was validated by five data sets collected by a UR5 robot. We tested the system on a plastisol phantom and showed that it can detect and track the fiducial marker while displaying the probe pose in real-time.

  10. Feasibility of a wireless gammar probe in radioguided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Min; Kim, Jeong Ho; Park, Chan Jong; Joo, Koan Sik [Dept. of Physics, University of Myongji, Seoul (Korea, Republic of)

    2016-04-15

    Nuclear medicine is divided into two major domains: diagnosis and therapy. Nuclear medicine diagnostic procedures are used for determining and evaluating the physiological, chemical, endocrinal, and metabolic conditions of organs or tissues. Tumors can be diagnosed based on the images provided by the associated machinery; after diagnosis, sometimes these tumors can be surgically removed. Currently, to help guide the surgeon to the exact location of the tumor site, the use of intraoperative probes has steadily gained popularity. These probes allow the physician to locate the tumor on the basis of the higher uptake of the preoperatively injected radio pharmaceutical within the site, as compared to the surrounding tissue. Direct detection offers very good energy resolution, but the detection efficiency is low; on the other hand, indirect detection presents high efficiency and low energy resolution. For this reason, the use of both detectors is recommended for obtaining an accurate localization of the diagnostic and therapeutic fields. In the literature, there are several works that aim to develop a suitable probe that presents such characteristics (i.e., good resolution, high detection efficiency, as well as the capacity for miniaturization). In this study, a wireless gamma probe is designed for the detection of tumors of the tissue surface using a silicon photomultiplier (SiPM) and a cerium-doped gadolinium aluminum gallium garnet (Ce:GAGG) scintillator. Our experiments demonstrate the feasibility of wireless diagnostics, as well as the suitable energy resolution and spatial resolution. The system developed based on the results of this study is expected to perform intraoperative or diagnostic evaluations of residual lesions (or the absence thereof) and its quantitative distribution in the affected area, thus contributing to wireless diagnostics and screening systems.

  11. Intrauterine photoacoustic and ultrasound imaging probe.

    Science.gov (United States)

    Miranda, Christopher; Barkley, Joel; Smith, Barbara

    2018-04-01

    Intrauterine photoacoustic and ultrasound imaging are probe-based imaging modalities with translational potential for use in detecting endometrial diseases. This deep-tissue imaging probe design allows for the retrofitting of commercially available endometrial sampling curettes. The imaging probe presented here has a 2.92-mm diameter and approximate length of 26 cm, which allows for entry into the human endometrial cavity, making it possible to use photoacoustic imaging and high-resolution ultrasound to characterize the uterus. We demonstrate the imaging probes' ability to provide structural information of an excised pig uterus using ultrasound imaging and detect photoacoustic signals at a radial depth of 1 cm. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  12. Thorascopic resection of an apical paraspinal schwannoma using the da Vinci surgical system.

    Science.gov (United States)

    Finley, David; Sherman, Jonathan H; Avila, Edward; Bilsky, Mark

    2014-01-01

    Posterior mediastinal neurogenic tumors have traditionally been resected via an open posterolateral thoracotomy. Video-assisted thorascopic surgery has emerged as an alternative technique allowing for improved morbidity with decreased blood loss, less postoperative pain, and a shorter recovery period, among others. The da Vinci surgical system, as first described for urologic procedures, has recently been reported for lung lobectomy. This technique provides the advantages of instrumentation with 6 degrees of freedom, stable operating arms, and improved visualization with the three-dimensional high-definition camera. We describe the technique for thorascopic resection of an apical paraspinal schwannoma of the T1 nerve root with the da Vinci surgical system. This technique used a specialized intraoperative neuromonitoring probe for free-running electromyography (EMG) and triggered EMG. We demonstrate successful resection of a posterior paraspinal schwannoma with the da Vinci surgical system while preserving neurologic function. The patient displayed stable intraoperative monitoring of the T1 nerve root and full intrinsic hand strength postoperatively. The technique described in this article introduces robotic system accuracy and precludes the need for an open thoracotomy. In addition, this approach demonstrates the ability of the da Vinci surgical system to safely dissect tumors from their neural attachments and is applicable to other such lesions of similar size and location. Georg Thieme Verlag KG Stuttgart · New York.

  13. Electrical resistivity probes

    Science.gov (United States)

    Lee, Ki Ha; Becker, Alex; Faybishenko, Boris A.; Solbau, Ray D.

    2003-10-21

    A miniaturized electrical resistivity (ER) probe based on a known current-voltage (I-V) electrode structure, the Wenner array, is designed for local (point) measurement. A pair of voltage measuring electrodes are positioned between a pair of current carrying electrodes. The electrodes are typically about 1 cm long, separated by 1 cm, so the probe is only about 1 inch long. The electrodes are mounted to a rigid tube with electrical wires in the tube and a sand bag may be placed around the electrodes to protect the electrodes. The probes can be positioned in a borehole or on the surface. The electrodes make contact with the surrounding medium. In a dual mode system, individual probes of a plurality of spaced probes can be used to measure local resistance, i.e. point measurements, but the system can select different probes to make interval measurements between probes and between boreholes.

  14. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    Science.gov (United States)

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  15. Thioglycolic acid-capped CuInS2/ZnS quantum dots as fluorescent probe for cobalt ion detection

    International Nuclear Information System (INIS)

    Zi, Lili; Huang, Yu; Yan, Zhengyu; Liao, Shenghua

    2014-01-01

    A novel sensing fluorescent probe based on the fluorescence quenching of the thioglycolic acid-capped CuInS 2 /ZnS quantum dots (CuInS 2 /ZnS/TGA QDs) was established for cobalt ions detection. The fluorescence quenching of CuInS 2 /ZnS/TGA QDs was due to the increasing surface deficiency and the inner-filter effect, which were attributed to the reaction between Co 2+ and sulfur bonds on the surface of QDs. The quenching curve could be fitted by a typical Stern–Volmer-type equation, with a linear relationship between the quenching efficiency and the concentration of cobalt ions in the range of 0.3012–90.36 μmol L −1 . And the detection limit (S/N=3) for Co 2+ was 0.16 μmol L −1 . Therefore, the established probe provided a simple, rapid, cheap and sensitive method for Co 2+ detection. In a word, this method can be used to detect Co 2+ in the environment. -- Highlights: • The CuInS2/ZnS QDs were used for the first time as a fluorescent probe for Co 2+ detection. • The dramatic color change could be observed when Co 2+ was added into the QDs solution. • The quenching of QDs was due to the increasing surface deficiency and the inner-filter effect. • This rapid, cheap and sensitive method was applied to the detection of Co 2+ in simulated water

  16. Synthesis and sensor activity of a PET-based 1,8-naphthalimide Probe for Zn(2+) and pH determination.

    Science.gov (United States)

    Dimov, Stefan M; Georgiev, Nikolai I; Asiri, Abdullah M; Bojinov, Vladimir B

    2014-11-01

    A novel blue-emitting 1,8-naphthalimide fluorophore designed as a molecular PET-based probe for determination of pH and detection of transition metal ions in the environment was successfully synthesized. Novel compound was configured on the "fluorophore-spacer-receptor" format. Due to the tertiary amine receptor the novel system showed "off-on" switching properties under the transition from alkaline to acid media (FE = 3.2) and in the presence of Zn(2+) ions (FE = 2.5). The results obtained illustrate the high potential of the synthesized blue-emitting 1,8-naphthalimide fluorophore as an efficient pH chemosensing material and a selective probe for Zn(2+) ions.

  17. Quantifying surgical access in eyebrow craniotomy with and without orbital bar removal: cadaver and surgical phantom studies.

    Science.gov (United States)

    Zador, Zsolt; Coope, David J; Gnanalingham, Kanna; Lawton, Michael T

    2014-04-01

    Eyebrow craniotomy is a recently described minimally invasive approach for tackling primarily pathology of the anterior skull base. The removal of the orbital bar may further expand the surgical corridor of this exposure, but the extent of benefit is poorly quantified. We assessed the effect of orbital bar removal with regards to surgical access in the eyebrow craniotomy using classic morphometric measurements in cadaver heads. Using surgical phantoms and neuronavigation, we also measured the 'working volume', a new parameter for characterising the volume of surgical access in these approaches. Silicon injected cadaver heads (n = 5) were used for morphometric analysis of the eyebrow craniotomy with and without orbital bar removal. Working depths and 'working areas' of surgical access were measured as defined by key anatomical landmarks. The eyebrow craniotomy with or without orbital bar removal was also simulated using surgical phantoms (n = 3, 90-120 points per trial), calibrated against a frameless neuronavigation system. Working volume was derived from reference coordinates recorded along the anatomical borders of the eyebrow craniotomy using the "α-shape algorithm" in R statistics. In cadaver heads, eyebrow craniotomy with removal of the orbital bar reduced the working depth to the ipsilateral anterior clinoid process (42 ± 2 versus 33 ± 3 mm; p < 0.05), but the working areas as defined by deep neurovascular and bony landmarks was statistically unchanged (total working areas of 418 ± 80 cm(2) versus 334 ± 48 cm(2); p = 0.4). In surgical phantom studies, however, working-volume for the simulated eyebrow craniotomies was increased with orbital bar removal (16 ± 1 cm(3) versus 21 ± 1 cm(3); p < 0.01). In laboratory studies, orbital bar removal in eyebrow craniotomy provides a modest reduction in working depth and increase in the working volume. But this must be weighed up against the added morbidity of the

  18. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    黄承志; 李原芳; 黄新华; 范美坤

    2000-01-01

    The microarray of DNA probes with 5’ -NH2 and 5’ -Tex/3’ -NH2 modified terminus on 10 um carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) is characterized in the preseni paper. it was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentra-tion of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  19. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The microarray of DNA probes with 5′-NH2 and 5′-Tex/3′-NH2 modified terminus on 10 m m carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)- carbodiimide (EDC) is characterized in the present paper. It was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentration of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  20. CD2 probe infrared method for determining polymethylene chain conformation

    International Nuclear Information System (INIS)

    Maroncelli, M.; Strauss, H.L.; Snyder, R.G.

    1985-01-01

    The rocking mode frequency of a CD 2 group substituted in a polymethylene chain is sensitive to conformation in the immediate vicinity of the CD 2 group. This sensitivity forms the basis of a commonly used infrared method for determining site-specific conformation in polymethylene systems. In the present work, the CD 2 probe method has been extended and quantified with the use of infrared data on model CD 2 -substituted n-alkanes. The frequency of the CD 2 rocking band is determined primarily by the conformation of adjoining CC bonds, i.e., by tt, gt, and gg pairs. However, we have found that there are significant frequency shifts associated with other factors. These include the conformation of the next nearest CC bonds, both with the CD 2 positioned at the end and in the interior of the chain, and chain length. In addition, the ratio of the absorptivities of the tt to gt bands has been established. These results enable the method to provide new details about the conformation of the chains in polymethylene systems and reliable estimates of the concentrations of specific kinds of short conformational sequences. 14 references, 6 figures, 2 tables

  1. [Surgical complications of colostomies].

    Science.gov (United States)

    Ben Ameur, Hazem; Affes, Nejmeddine; Rejab, Haitham; Abid, Bassem; Boujelbene, Salah; Mzali, Rafik; Beyrouti, Mohamed Issam

    2014-07-01

    The colostomy may be terminal or lateral, temporary or permanent. It may have psychological, medical or surgical complications. reporting the incidence of surgical complications of colostomies, their therapeutic management and trying to identify risk factors for their occurrence. A retrospective study for a period of 5 years in general surgery department, Habib Bourguiba hospital, Sfax, including all patients operated with confection of a colostomy. Were then studied patients reoperated for stoma complication. Among the 268 patients who have had a colostomy, 19 patients (7%) developed surgical stoma complications. They had a mean age of 59 years, a sex ratio of 5.3 and a 1-ASA score in 42% of cases. It was a prolapse in 9 cases (reconfection of the colostomy: 6 cases, restoration of digestive continuity: 3 cases), a necrosis in 5 cases (reconfection of the colostomy), a plicature in 2 cases (reconfection of the colostomy) a peristomal abscess in 2 cases (reconfection of the colostomy: 1 case, restoration of digestive continuity: 1 case) and a strangulated parastomal hernia in 1 case (herniorrhaphy). The elective incision and the perineal disease were risk factors for the occurrence of prolapse stomial. Surgical complications of colostomies remain a rare event. Prolapse is the most common complication, and it is mainly related to elective approach. Reoperation is often required especially in cases of early complications, with usually uneventful postoperative course.

  2. 2016 CAPS ethics session/Ein debate: 1. Regionalization of pediatric surgical care 2. Ethical introduction of surgical innovation 3. Addressing stress in a surgical practice: resiliency, well-being, and burnout.

    Science.gov (United States)

    Bagwell, Charles E; Chiu, Priscilla; Fecteau, Annie; Gow, Kenneth W; Mueller, Claudia M; Price, David; Zigman, Andrew F

    2017-05-01

    The following is the conference proceeding of the Second Ein Debate from the 48th Annual Meeting of the Canadian Association of Paediatric Surgeons held in Vancouver, BC, from September 22 to 24, 2016. The three main topics for debate, as prepared by the members of the CAPS Ethics Committee, are: 1. Regionalization of care: pros and cons, 2. Innovation in clinical care: ethical considerations, and 3. Surgeon well-being: caring for the caregiver. The authors of this paper, as participants in the debate, were assigned their positions at random. Therefore, the opinions they express within this summary might not reflect their own viewpoints. In the first discussion, arguments for and against the regionalization of pediatric surgical care are discussed, primarily in the context of a case of BA. In the pro argument, the evidence and lessons learned from different European countries are explored as well as different models to provide the best BA care outside of large teaching centers. In the counterargument, the author explains how regionalization of care could be detrimental for the patient, the family, the regional center, and for the health care system in general. In the debate on surgical innovation the authors define surgical innovation. They review the pertinent ethical principles, explore a model for its implementation, and the role of the institution at which the innovation is proposed. In the third section, surgeon well-being is examined, and recent literature on surgeon resiliency and burnout both at the attending and resident level is reviewed. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. A new fluorescent pyrene–pyridine dithiocarbamate probe: A chemodosimeter to detect Hg2+ in pure aqueous medium and in live cells

    International Nuclear Information System (INIS)

    Singh, Vikram; Srivastava, Priyanka; PrakashVerma, Shiv; Misra, Arvind; Das, Parimal; Singh, Nanhai

    2014-01-01

    A new pyrene–pyridine dithiocarbamate based fluorescent chemodosimeter, potassium (pyren-1-ylmethyl)(pyridin-2-ylmethyl)dithiocarbamate (L1) has been designed and synthesized. The chemodosimeter shows high selectivity and sensitivity (5.2 ppb) for Hg 2+ in pure aqueous medium in which emission intensity was quenched by ≈80% due to the formation of new cyclized species, 1. The probe behaves as a chemodosimeter for Hg 2+ ions and forms Hg 2+ triggered cyclised imidazoline species with approximate detection time of 50 s and exhibits both colorimetric and fluorometric changes on detection of Hg 2+ ion. Color of the probe (L1) changed from green to colorless visible to the naked eye and from green to dark blue upon the addition of Hg 2+ ions under UV light. The Hg 2+ triggered cyclization reaction was confirmed by spectral data analysis and a single crystal structure determination of the cyclised entity 2 obtained from the model compound potassium benzyl(pyridin-2-ylmethyl) dithiocarbamate (L2). L1 finds its application for detection of Hg 2+ ions on paper strips, and in BSA (bovine serum albumin) medium. L1 is also applicable for the monitoring of Hg 2+ ion in NIH3T3 live cells. - Highlights: • Efficient chemodosimeter to detect Hg 2+ ions in pure aqueous medium. • Hg 2+ triggered cyclisation and formation of imidazoline species. • Probe exhibit both colorimetric and fluorometric changes • Probe is applicable to detect Hg 2+ in live cells and on cellulose paper strips

  4. Micro-surgical endodontics.

    Science.gov (United States)

    Eliyas, S; Vere, J; Ali, Z; Harris, I

    2014-02-01

    Non-surgical endodontic retreatment is the treatment of choice for endodontically treated teeth with recurrent or residual disease in the majority of cases. In some cases, surgical endodontic treatment is indicated. Successful micro-surgical endodontic treatment depends on the accuracy of diagnosis, appropriate case selection, the quality of the surgical skills, and the application of the most appropriate haemostatic agents and biomaterials. This article describes the armamentarium and technical procedures involved in performing micro-surgical endodontics to a high standard.

  5. TORE SUPRA fast reciprocating radio frequency probe

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.; Kwon, M.; Goulding, R.H.; Hoffman, D.J.; Saoutic, B.; Becoulet, A.; Fraboulet, D.; Beaumont, B.; Kuus, H.; Ladurelle, L.; Pascal, J.Y.

    1995-01-01

    A fast reciprocating ion cyclotron range of frequencies (ICRF) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at Oak Ridge National Laboratory. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal rf magnetic fields and the other senses poloidal rf magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/s) of 30 cm and a fast stroke (1.5 m/s) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition, and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data show parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  6. High spatial resolution Kelvin probe force microscopy with coaxial probes

    International Nuclear Information System (INIS)

    Brown, Keith A; Westervelt, Robert M; Satzinger, Kevin J

    2012-01-01

    Kelvin probe force microscopy (KPFM) is a widely used technique to measure the local contact potential difference (CPD) between an AFM probe and the sample surface via the electrostatic force. The spatial resolution of KPFM is intrinsically limited by the long range of the electrostatic interaction, which includes contributions from the macroscopic cantilever and the conical tip. Here, we present coaxial AFM probes in which the cantilever and cone are shielded by a conducting shell, confining the tip–sample electrostatic interaction to a small region near the end of the tip. We have developed a technique to measure the true CPD despite the presence of the shell electrode. We find that the behavior of these probes agrees with an electrostatic model of the force, and we observe a factor of five improvement in spatial resolution relative to unshielded probes. Our discussion centers on KPFM, but the field confinement offered by these probes may improve any variant of electrostatic force microscopy. (paper)

  7. Surgical options for treatment of traumatic subdural hematomas in children younger than 2 years of age.

    Science.gov (United States)

    Melo, José Roberto Tude; Di Rocco, Federico; Bourgeois, Marie; Puget, Stephanie; Blauwblomme, Thomas; Sainte-Rose, Christian; Meyer, Philippe G; Zerah, Michel

    2014-04-01

    Subdural hematoma (SDH) is the most common finding on cranial CT in pediatric victims of abusive head trauma (AHT). The hematomas are commonly bilateral and sometimes associated with interhemispheric hyperdensity and/or convexity hemorrhages. There is no consensus regarding the best surgical treatment in such cases nor are there standardized surgical protocols. The authors report their experience and discuss the routine surgical options in the management of traumatic SDH at a Level 1 Pediatric Trauma Center. In this paper, the authors describe a cross-sectional study with consecutive revision of data described in the medical records of Hôpital Universitaire Necker-Enfants Malades between January 2008 and January 2013. During this period, all children younger than 2 years of age who were admitted with a traumatic SDH identified on CT scans were included in this study. One hundred eighty-four children who had SDH and were younger than 2 years of age were included. Their median age was 5.8 months (range 5 days-23 months), and 70% of the children were male. On admission CT scans, the SDH was bilateral in 52% of cases and homogeneously hypodense in 77%. Neurosurgical treatment was undertaken in 111 children (60%) with an admission Glasgow Coma Scale score of 12 or less, bulging fontanels, or other signs suggestive of intracranial hypertension. The first surgical option was craniotomy in 1.8% (2) of these 111 cases, decompressive craniectomy in 1.8% (2), transcutaneous subdural puncture in 15% (17), external subdural drainage in 16% (18), subdural-subgaleal shunt placement in 17% (19), and subdural-peritoneal shunt placement in 48% (53). In 82% of the children initially treated with transcutaneous subdural puncture and in 50% of those treated with external subdural drainage, increase or persistence of the SDH, CSF or skin infection, or shunt system malfunction was observed and further surgical intervention was required. There was a 26% rate of complications in patients

  8. Blinded Comparison between an In-Air Reverberation Method and an Electronic Probe Tester in the Detection of Ultrasound Probe Faults.

    Science.gov (United States)

    Dudley, Nicholas J; Woolley, Darren J

    2017-12-01

    The aim of this study was to perform a blinded trial, comparing the results of a visual inspection of the in-air reverberation pattern with the results of an electronic probe tester in detecting ultrasound probe faults. Sixty-two probes were tested. A total of 28 faults were found, 3 only by in-air reverberation assessment and 2 only by the electronic probe tester. The electronic probe tester provided additional information regarding the location of the fault in 74% of the cases in which both methods detected a fault. It is possible to detect the majority of probe faults by visual inspection and in-air reverberation assessment. The latter provides an excellent first-line test, easily performed on a daily basis by equipment users. An electronic probe tester is required if detailed evaluation of faults is necessary. Copyright © 2017 World Federation for Ultrasound in Medicine and Biology. All rights reserved.

  9. Evaluation of Flat Surface Temperature Probes

    Science.gov (United States)

    Beges, G.; Rudman, M.; Drnovsek, J.

    2011-01-01

    The objective of this paper is elaboration of elements related to metrological analysis in the field of surface temperature measurement. Surface temperature measurements are applicable in many fields. As examples, safety testing of electrical appliances and a pharmaceutical production line represent case studies for surface temperature measurements. In both cases correctness of the result of the surface temperature has an influence on final product safety and quality and thus conformity with specifications. This paper deals with the differences of flat surface temperature probes in measuring the surface temperature. For the purpose of safety testing of electrical appliances, surface temperature measurements are very important for safety of the user. General requirements are presented in European standards, which support requirements in European directives, e.g., European Low Voltage Directive 2006/95/EC and pharmaceutical requirements, which are introduced in official state legislation. This paper introduces a comparison of temperature measurements of an attached thermocouple on the measured surface and measurement with flat surface temperature probes. As a heat generator, a so called temperature artifact is used. It consists of an aluminum plate with an incorporated electrical heating element with very good temperature stability in the central part. The probes and thermocouple were applied with different forces to the surface in horizontal and vertical positions. The reference temperature was measured by a J-type fine-wire (0.2 mm) thermocouple. Two probes were homemade according to requirements in the European standard EN 60335-2-9/A12, one with a fine-wire (0.2 mm) thermocouple and one with 0.5mm of thermocouple wire diameter. Additional commercially available probes were compared. Differences between probes due to thermal conditions caused by application of the probe were found. Therefore, it can happen that measurements are performed with improper equipment or

  10. Introduction of argon beam coagulation functionality to robotic procedures using the ABC D-Flex probe: equivalency to an existing laparoscopic instrument

    Science.gov (United States)

    Merchel, Renée. A.; Barnes, Kelli S.; Taylor, Kenneth D.

    2015-03-01

    INTRODUCTION: The ABC® D-Flex Probe utilizes argon beam coagulation (ABC) technology to achieve hemostasis during minimally invasive surgery. A handle on the probe allows for integration with robotic surgical systems and introduces ABC to the robotic toolbox. To better understand the utility of D-Flex, this study compares the performance of the D-Flex probe to an existing ABC laparoscopic probe through ex vivo tissue analysis. METHODS: Comparisons were performed to determine the effect of four parameters: ABC device, tissue type, activation duration, and distance from tissue. Ten ABC D-Flex probes were used to create 30 burn samples for each comparison. Ex vivo bovine liver and porcine muscle were used as tissue models. The area and depth of each burn was measured using a light microscope. The resulting dimensional data was used to correlate tissue effect with each variable. RESULTS: D-Flex created burns which were smaller in surface area than the laparoscopic probe at all power levels. Additionally, D-Flex achieved thermal penetration levels equivalent to the laparoscopic probe. CONCLUSION: D-Flex implements a small 7F geometry which creates a more focused beam. When used with robotic precision, quick localized superficial hemostasis can be achieved with minimal collateral damage. Additionally, D-Flex achieved equivalent thermal penetration levels at lower power and argon flow-rate settings than the laparoscopic probe.

  11. 2D electron density profile measurement in tokamak by laser-accelerated ion-beam probe.

    Science.gov (United States)

    Chen, Y H; Yang, X Y; Lin, C; Wang, L; Xu, M; Wang, X G; Xiao, C J

    2014-11-01

    A new concept of Heavy Ion Beam Probe (HIBP) diagnostic has been proposed, of which the key is to replace the electrostatic accelerator of traditional HIBP by a laser-driven ion accelerator. Due to the large energy spread of ions, the laser-accelerated HIBP can measure the two-dimensional (2D) electron density profile of tokamak plasma. In a preliminary simulation, a 2D density profile was reconstructed with a spatial resolution of about 2 cm, and with the error below 15% in the core region. Diagnostics of 2D density fluctuation is also discussed.

  12. Evaluation of adherence to measures for the prevention of surgical site infections by the surgical team

    Directory of Open Access Journals (Sweden)

    Adriana Cristina de Oliveira

    2015-10-01

    Full Text Available AbstractOBJECTIVEEvaluate pre- and intraoperative practices adopted by medical and nursing teams for the prevention of surgical infections.METHODA prospective study carried out in the period of April to May 2013, in a surgical center of a university hospital in Belo Horizonte, Minas Gerais.RESULTS18 surgeries were followed and 214 surgical gloves were analyzed, of which 23 (10.7% had postoperative glove perforation detected, with 52.2% being perceived by users. Hair removal was performed on 27.7% of patients in the operating room, with the use of blades in 80% of the cases. Antibiotic prophylaxis was administered to 81.8% of patients up to 60 minutes prior to surgical incision. An average of nine professionals were present during surgery and the surgery room door remained open in 94.4% of the procedures.CONCLUSIONPartial adhesion to the recommended measures was identified, reaffirming a need for greater attention to these critical steps/actions in order to prevent surgical site infection.

  13. Comparison of CDE data in phacoemulsification between an open hospital-based ambulatory surgical center and a free-standing ambulatory surgical center.

    Science.gov (United States)

    Chen, Ming; Chen, Mindy

    2010-11-12

    Mean CDE (cumulative dissipated energy) values were compared for an open hospital- based surgical center and a free-standing surgical center. The same model of phacoemulsifier (Alcon Infiniti Ozil) was used. Mean CDE values showed that surgeons (individual private practice) at the free-standing surgical center were more efficient than surgeons (individual private practice) at the open hospital-based surgical center (mean CDE at the hospital-based surgical center 18.96 seconds [SD = 12.51]; mean CDE at the free-standing surgical center 13.2 seconds [SD = 9.5]). CDE can be used to monitor the efficiency of a cataract surgeon and surgical center in phacoemulsification. The CDE value may be used by institutions as one of the indicators for quality control and audit in phacoemulsification.

  14. Simulation-aided design and fabrication of nanoprobes for scanning probe microscopy

    International Nuclear Information System (INIS)

    Liu, Bernard Haochih; Chang, Day-Bin

    2011-01-01

    We proposed and demonstrated a flexible and effective method to design and fabricate scanning probes for atomic force microscopy applications. Computer simulations were adopted to evaluate design specifications and desired performance of atomic force microscope (AFM) probes; the fabrication processes were guided by feedback from simulation results. Through design-simulation-fabrication iterations, tipless cantilevers and tapping mode probes were successfully made with errors as low as 2% in designed resonant frequencies. For tapping mode probes, the probe tip apex achieved a 10 nm radius of curvature without additional sharpening steps; tilt-compensated probes were also fabricated for better scanning performance. This method provides AFM users improved probe quality and practical guidelines for customized probes, which can support the development of novel scanning probe microscopy (SPM) applications. -- Research highlights: → We developed a design-simulation-fabrication strategy for customized AFM/SPM probes and demonstrated the results of tipless cantilever, sharpened probe tip, and tilt-compensated probe. → This simulation-aided method improved the geometry control and performance prediction of AFM probes; the error in resonant frequency was reduced to ∼2%. → Integration of simulation in design and fabrication of AFM probes expedites development of new probes and consequently promotes novel SPM applications.

  15. The impact of a surgical boot camp on early acquisition of technical and nontechnical skills by novice surgical trainees.

    Science.gov (United States)

    Heskin, Leonie; Mansour, Ehab; Lane, Brian; Kavanagh, Dara; Dicker, Pat; Ryan, Donncha; Gildea-Byrne, Kate; Pawlikowska, Teresa; Tierney, Sean; Traynor, Oscar

    2015-09-01

    Acquisition of skills early in surgical training represents a significant challenge at present because of training time constraints. The aim of this study was to investigate if an intensive surgical boot camp was effective in transferring skills at the beginning of a surgical training program. New core surgical trainees (n = 58) took part in a 5-day boot camp. There were pretest and posttest assessments of knowledge, technical skills, and confidence levels. The boot camp used simulation and senior surgical faculty to teach a defined range of technical and nontechnical skills. The scores for knowledge (53.8% vs 68.4%, P technical skills (35.9% to 60.6% vs 50.6% to 78.2%, P Skills improvements were still present a year later. The 5-day surgical boot camp proved to be an effective way to rapidly acquire surgical knowledge and skills while increasing the confidence levels of trainees. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. C3H2 observations as a diagnostic probe for molecular clouds

    Science.gov (United States)

    Avery, L. W.

    1986-01-01

    Recently the three-membered ring molecule, cyclopropenylidene, C3H2, has been identified in the laboratory and detected in molecular clouds by Thaddeus, Vrtilek and Gottlieb (1985). This molecule is wide-spread throughout the Galaxy and has been detected in 25 separate sources including cold dust clouds, circumstellar envelopes, HII regions, and the spiral arms observed against the Cas supernova remnant. In order to evaluate the potential of C3H2 as a diagnostic probe for molecular clouds, and to attempt to identify the most useful transitions, statistical equilibrium calculations were carried out for the lowest 24 levels of the ortho species and the lowest 10 levels of the para species. Many of the sources observed by Matthews and Irvine (1985) show evidence of being optically thick in the 1(10)-1(01) line. Consequently, the effects of radiative trapping should be incorporated into the equilibrium calculations. This was done using the Large Velocity Gradient approximation for a spherical cloud of uniform density. Some results of the calculations for T(K)=10K are given. Figures are presented which show contours of the logarithm of the ratio of peak line brightness temperatures for ortho-para pairs of lines at similar frequencies. It appears that the widespread nature of C3H2, the relatively large strength of its spectral lines, and their sensitivity to density and molecular abundance combine to make this a useful molecule for probing physical conditions in molecular clouds. The 1(10)-1(01) and 2(20)-2(11) K-band lines may be especially useful in this regard because of the ease with which they are observed and their unusual density-dependent emission/absorption properties.

  17. Improved multiplex ligation-dependent probe amplification analysis identifies a deleterious PMS2 allele generated by recombination with crossover between PMS2 and PMS2CL

    OpenAIRE

    Wernstedt, Annekatrin; Valtorta, Emanuele; Armelao, Franco; Togni, Roberto; Girlando, Salvatore; Baudis, Michael; Heinimann, Karl; Messiaen, Ludwine; Staehli, Noemie; Zschocke, Johannes; Marra, Giancarlo; Wimmer, Katharina

    2012-01-01

    Heterozygous PMS2 germline mutations are associated with Lynch syndrome. Up to one third of these mutations are genomic deletions. Their detection is complicated by a pseudogene (PMS2CL), which – owing to extensive interparalog sequence exchange – closely resembles PMS2 downstream of exon 12. A recently redesigned multiplex ligation-dependent probe amplification (MLPA) assay identifies PMS2 copy number alterations with improved reliability when used with reference DNAs containing equal number...

  18. Development of the mercury iodide semiconductor crystal for application as a radiation detector

    International Nuclear Information System (INIS)

    Martins, Joao Francisco Trencher

    2011-01-01

    In this work, the establishment of a technique for HgI growth and preparation of crystals, for use as room temperature radiation semiconductor detectors is described. Three methods of crystal growth were studied while developing this work: physical vapor transport (PVT); saturated solution of HgI 2 , using two different solvents; (a) dimethyl sulfoxide (DMSO) and (b) acetone, and the Bridgman method. In order to evaluate the obtained crystals by the three methods, systematic measurements were carried out for determining the stoichiometry, structure, orientation, surface morphology and impurity of the crystal. The influence of these physical chemical properties on the crystals development was studied, evaluating their performance as radiation detectors. The X-ray diffractograms indicated that the crystals were, preferentially, oriented in the (001) e (101) directions with tetragonal structure for all crystals. Nevertheless, morphology with a smaller deformation level was observed for the crystal obtained by the PVT technique, comparing to other methods. Uniformity on the surface layer of the PVT crystal was detected, while clear incrustations of elements distinct from the crystal could be viewed on the DMSO crystal surface. The best results as to radiation response were found for the crystal grown by physical vapor transport. Significant improvement in the HgI z2 radiation detector performance was achieved for purer crystals, growing the crystal twice by PVT technique. (author)

  19. More on Probing Branes with Branes

    OpenAIRE

    Brandhuber, A.; Itzhaki, N.; Sonnenschein, J.; Yankielowicz, S.

    1997-01-01

    We generalize the Gibbons-Wiltshire solution of four dimensional Kaluza-Klein black holes in order to describe Type IIA solutions of bound states of D6 and D0-branes. We probe the solutions with a D6-brane and a D0-brane. We also probe a system of D2+D0-branes and of a D2-brane bound to a F1-string with a D2-brane. A precise agreement between the SYM and the SUGRA calculations is found for the static force as well as for the $v^2$ force in all cases.

  20. Prospective Analysis of Surgical Bone Margins After Partial Foot Amputation in Diabetic Patients Admitted With Moderate to Severe Foot Infections.

    Science.gov (United States)

    Schmidt, Brian M; McHugh, Jonathan B; Patel, Rajiv M; Wrobel, James S

    2018-04-01

    Osteomyelitis is common in diabetic foot infections and medical management can lead to poor outcomes. Surgical management involves sending histopathologic and microbiologic specimens which guides future intervention. We examined the effect of obtainment of surgical margins in patients undergoing forefoot amputations to identify patient characteristics associated with outcomes. Secondary aims included evaluating interobserver reliability of histopathologic data at both the distal-to and proximal-to surgical bone margin. Data were prospectively collected on 72 individuals and was pooled for analysis. Standardized method to retrieve intraoperative bone margins was established. A univariate analysis was performed. Negative outcomes, including major lower extremity amputation, wound dehiscence, reulceration, reamputation, or death were recorded. Viable proximal margins were obtained in 63 out of 72 cases (87.5%). Strong interobserver reliability of histopathology was recorded. Univariate analysis demonstrated preoperative platelets, albumin, probe-to-bone testing, absolute toe pressures, smaller wound surface area were associated with obtaining viable margins. Residual osteomyelitis resulted in readmission 2.6 times more often and more postoperative complications. Certain patients were significantly different in the viable margin group versus dirty margin group. High interobserver reliability was demonstrated. Obtainment of viable margins resulted in reduced rates of readmission and negative outcomes. Prognostic, Level I: Prospective.

  1. Mobile surgical skills education unit: a new concept in surgical training.

    Science.gov (United States)

    Shaikh, Faisal M; Hseino, Hazem; Hill, Arnold D K; Kavanagh, Eamon; Traynor, Oscar

    2011-08-01

    Basic surgical skills are an integral part of surgical training. Simulation-based surgical training offers an opportunity both to trainees and trainers to learn and teach surgical skills outside the operating room in a nonpatient, nonstressed environment. However, widespread adoption of simulation technology especially in medical education is prohibited by its inherent higher cost, limited space, and interruptions to clinical duties. Mobile skills laboratory has been proposed as a means to address some of these limitations. A new program is designed by the Royal College of Surgeons in Ireland (RCSI), in an approach to teach its postgraduate basic surgical trainees the necessary surgical skills, by making the use of mobile innovative simulation technology in their own hospital settings. In this article, authors describe the program and students response to the mobile surgical skills being delivered in the region of their training hospitals and by their own regional consultant trainers.

  2. Innovative Design of a Laparoscopic Probe for Non-Invasive Intraoperative Detection of Small Endoluminal Digestive Tumours

    Directory of Open Access Journals (Sweden)

    Bogdan Mocan

    2015-12-01

    Full Text Available The present paper highlights the design methodology, the prototype development and the ex-vivo testing of a sensing laparoscopic probe that could be used by surgeons and by surgeon’s assistive robotic systems for detection of small endoluminal digestive tumours. The proposed design framework guides the decision-makers towards a superior balance between quality, efficiency and surgical procedure issues in medical instruments development. A prototype of the sensitive laparoscopic probe for non-invasive intraoperative detection of small endoluminal digestive tumours was developed. The prototype was tested in ex-vivo experimental conditions – open and laparoscopic surgery. The results reveals that the developed prototype is easy to use, adequate and efficient in precise detection of small endoluminal digestive tumours in-between 60÷85% of cases.

  3. 1-(2-Methyl-5H-chromeno[2,3-b]pyridin-5-ylidene) hydrazone as fluorescent probes for selective zinc sensing in DMSO

    Energy Technology Data Exchange (ETDEWEB)

    Nouri, Hela [URCA—Institut de Chimie Moléculaire de Reims, CNRS UMR 7312, Groupe Chimie de Coordination, UFR Sciences, BP 1039, 51687 Reims Cedex 2 (France); LACReSNE—Université de Carthage, Faculté des Sciences de Bizerte, 7021 Zarzouna Bizerte (Tunisia); Cadiou, Cyril, E-mail: cyril.cadiou@univ-reims.fr [URCA—Institut de Chimie Moléculaire de Reims, CNRS UMR 7312, Groupe Chimie de Coordination, UFR Sciences, BP 1039, 51687 Reims Cedex 2 (France); Henry, Axelle; Déchamps-Olivier, Isabelle [URCA—Institut de Chimie Moléculaire de Reims, CNRS UMR 7312, Groupe Chimie de Coordination, UFR Sciences, BP 1039, 51687 Reims Cedex 2 (France); Ternane, Riadh; Trabelsi-Ayadi, Malika [LACReSNE—Université de Carthage, Faculté des Sciences de Bizerte, 7021 Zarzouna Bizerte (Tunisia); Lemercier, Gilles; Chuburu, Françoise [URCA—Institut de Chimie Moléculaire de Reims, CNRS UMR 7312, Groupe Chimie de Coordination, UFR Sciences, BP 1039, 51687 Reims Cedex 2 (France)

    2014-04-15

    Two methyl-chromeno-pyridinylidene hydrazone derivatives L1, a cyclen derivative, and L2 were studied as potential fluorescent OFF–ON sensors towards Zn{sup 2+} in DMSO. Upon addition of one equivalent of Zn{sup 2+}, L1 fluorescence was quenched, but addition of a second equivalent of Zn{sup 2+} restored partially the signal. Therefore ZnL1 behaved as a OFF–ON sensor for zinc. By comparison, L2 behaved as a very sensitive probe for zinc. ZnL1 and L2 sensor efficiencies were correlated to Zn{sup 2+} coordination via the hydrazone moiety of the fluorophore, which prevented a photoinduced electron transfer (PET), and allowed an efficient CHelation-Enhanced Fluorescence (CHEF) effect. -- Highlights: • According to Zn{sup 2+} concentration, L1 behaves as an on-off-on sensor. • Given that L1 concentration is known, its fluorescence response could give an immediate suggestion about the range of Zn{sup 2+} concentration. • L2 exhibited a strong fluorescence enhancement upon Zn{sup 2+} addition. • It was demonstrated that L2 was highly specific to Zn{sup 2+}, which rendered this very straightforward ligand as an efficient and selective probe for this ion.

  4. Radiographic Assessment of Bone Formation Using rhBMP2 at Maxillary Periapical Surgical Defects: A Case Series.

    Science.gov (United States)

    Kumar, M Siva; Kumar, M Hari; Vishalakshi, K; Sabitha, H

    2016-04-01

    Periapical cysts are the most common inflammatory odontogenic cysts arising from untreated dental caries with pulp necrosis and periapical infection. The choice of treatment is often influenced by various factors like size, extension of the lesion, proximity to vital structures, systemic condition and compliance of the patient too. The treatment protocol for management of periapical cysts is still under discussion and options vary from conservative treatment by means of endodontic technique to surgical treatment like decompression or a marsupialisation or even to enucleation. Large bony defect secondary to periapical surgery compromising the tooth integrity often requires bone graft to enhance bone formation and thus restoring function at the earliest. The present case series included 10 patients who had established periapical pathology secondary to history of trauma on upper anterior teeth as well patients with history of carious teeth with an apparent failure in root canal therapy. All ten patients were treated with cyst enucleation and apiceotomy along with 1.4cc Recombinant Human Bone Morphogenetic Protein-2 soaked Absorbable Collagen Sponge implantation at surgical defect. Radiographs and clinical examinations were done upto 3 months to evaluate healing. Radiographic and clinical assessments revealed bone regeneration and restoration of the maxillary surgical defects in all 10 patients. No evidence of graft failure was noted. The Recombinant Human Bone Morphogenetic Protein-2 soaked Absorbable Collagen Sponge carrier is thus proved to be a viable option for the treatment of maxillary periapical surgical defects.

  5. Tratamento cirúrgico das valvopatias: parte 2 Valvopathies: surgical treatment. Part 2

    Directory of Open Access Journals (Sweden)

    Domingo M Braile

    1994-09-01

    Full Text Available Esta segunda parte abordará técnica operatória, conduta pós-operatória e reoperações de pacientes com valvopatias. Em Técnica Operatória são descritos os procedimentos de anestesia, a abordagem cirúrgica, que inclui a instalação da circulação extracorpórea, e as cirurgias das valvas mitral, aórtica, tricúspide e pulmonar. Em Conduta Pós-Operatória é relatada a rotina na Unidade de Terapia Intensiva, e em Reoperações é abordada a técnica cirúrgica.This second part will cover operative technique, postoperative approach and reoperations of valvopathy patients. In Operative Technique, there is the description of the anesthesia procedures, surgical approach which includes the assembling of the extracorporeal circulation and surgeries of mitral, aortic, tricuspid and pulmonary valves. In the Postoperative Approach, the routine in the Intensive Care Unity is reported, and in Reoperations the surgical technique is covered.

  6. DNA probes

    International Nuclear Information System (INIS)

    Castelino, J.

    1992-01-01

    The creation of DNA probes for detection of specific nucleotide segments differs from ligand detection in that it is a chemical rather than an immunological reaction. Complementary DNA or RNA is used in place of the antibody and is labelled with 32 P. So far, DNA probes have been successfully employed in the diagnosis of inherited disorders, infectious diseases, and for identification of human oncogenes. The latest approach to the diagnosis of communicable and parasitic infections is based on the use of deoxyribonucleic acid (DNA) probes. The genetic information of all cells is encoded by DNA and DNA probe approach to identification of pathogens is unique because the focus of the method is the nucleic acid content of the organism rather than the products that the nucleic acid encodes. Since every properly classified species has some unique nucleotide sequences that distinguish it from every other species, each organism's genetic composition is in essence a finger print that can be used for its identification. In addition to this specificity, DNA probes offer other advantages in that pathogens may be identified directly in clinical specimens

  7. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  8. Interpretation of plasma impurity deposition probes. Analytic approximation

    Science.gov (United States)

    Stangeby, P. C.

    1987-10-01

    Insertion of a probe into the plasma induces a high speed flow of the hydrogenic plasma to the probe which, by friction, accelerates the impurity ions to velocities approaching the hydrogenic ion acoustic speed, i.e., higher than the impurity ion thermal speed. A simple analytic theory based on this effect provides a relation between impurity fluxes to the probe Γimp and the undisturbed impurity ion density nimp, with the hydrogenic temperature and density as input parameters. Probe size also influences the collection process and large probes are found to attract a higher flux density than small probes in the same plasma. The quantity actually measured, cimp, the impurity atom surface density (m-2) net-deposited on the probe, is related to Γimp and thus to nimp by taking into account the partial removal of deposited material caused by sputtering and the redeposition process.

  9. Complications of Intraoperative Transesophageal Echocardiography in Adult Cardiac Surgical Patients—Experience of Two Institutions in Taiwan

    Directory of Open Access Journals (Sweden)

    Chi-Hsiang Huang

    2007-01-01

    Full Text Available There is some safety concern about transesophageal echocardiography (TEE when it is used routinely during cardiac operations. The purpose of this investigation was to study the incidence of intraoperative TEE-associated complications in adult cardiac surgical patients. The study population comprised 6255 consecutive adult cardiac surgical patients with intraoperative TEE examinations. TEE-associated complications occurred in 25 patients (0.4%. Most of these complications consisted of oropharyngeal mucosal bleeding (15/25, 60%. Esophageal perforation occurred in one patient. Two patients experienced upper gastrointestinal bleeding. Seven patients experienced dental injuries, and TEE probe insertion failed in 10 patients. We conclude that intraoperative TEE-associated complications in cardiac operations is very low; the complication rate we found was comparable to previously reported values. [J Formos Med Assoc 2007; 106(1:92-95

  10. Defects in electron irradiated vitreous SiO2 probed by positron annihiliation

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro; Kawano, Takao; Itoh, Hisayoshi

    1994-01-01

    Defects in 3 MeV electron irradiated vitreous SiO 2 (v-SiO 2 ) were probed by the positron annihilation technique. For unirradiated v-SiO 2 specimens, almost all positrons were found to annihilate from positronium (Ps) states. This high formation probability of Ps was attributed to the trapping of positrons by open-space defects. The formation probability of Ps was decreased by the electron irradiation. The observed inhibition of the Ps formation was attributed to the trapping of positrons by point defects introduced and/or activated by the irradiation. From measurements of the lifetime distribution of Ps, it was found that, by the electron irradiation, the mean size of open-space defects was decreased and the size distribution of such defects was broadened. (Author)

  11. Output control of da Vinci surgical system's surgical graspers.

    Science.gov (United States)

    Johnson, Paul J; Schmidt, David E; Duvvuri, Umamaheswar

    2014-01-01

    The number of robot-assisted surgeries performed with the da Vinci surgical system has increased significantly over the past decade. The articulating movements of the robotic surgical grasper are controlled by grip controls at the master console. The user interface has been implicated as one contributing factor in surgical grasping errors. The goal of our study was to characterize and evaluate the user interface of the da Vinci surgical system in controlling surgical graspers. An angular manipulator with force sensors was used to increment the grip control angle as grasper output angles were measured. Input force at the grip control was simultaneously measured throughout the range of motion. Pressure film was used to assess the maximum grasping force achievable with the endoscopic grasping tool. The da Vinci robot's grip control angular input has a nonproportional relationship with the grasper instrument output. The grip control mechanism presents an intrinsic resistant force to the surgeon's fingertips and provides no haptic feedback. The da Vinci Maryland graspers are capable of applying up to 5.1 MPa of local pressure. The angular and force input at the grip control of the da Vinci robot's surgical graspers is nonproportional to the grasper instrument's output. Understanding the true relationship of the grip control input to grasper instrument output may help surgeons understand how to better control the surgical graspers and promote fewer grasping errors. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.; Amidan, Brett G.

    2014-09-30

    This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

  13. A minor groove binder probe real-time PCR assay for discrimination between type 2-based vaccines and field strains of canine parvovirus.

    Science.gov (United States)

    Decaro, Nicola; Elia, Gabriella; Desario, Costantina; Roperto, Sante; Martella, Vito; Campolo, Marco; Lorusso, Alessio; Cavalli, Alessandra; Buonavoglia, Canio

    2006-09-01

    A minor groove binder (MGB) probe assay was developed to discriminate between type 2-based vaccines and field strains of canine parvovirus (CPV). Considering that most of the CPV vaccines contain the old type 2, no longer circulating in canine population, two MGB probes specific for CPV-2 and the antigenic variants (types 2a, 2b and 2c), respectively, were labeled with different fluorophores. The MGB probe assay was able to discriminate correctly between the old type and the variants, with a detection limit of 10(1) DNA copies and a good reproducibility. Quantitation of the viral DNA loads was accurate, as demonstrated by comparing the CPV DNA titres to those calculated by means of the TaqMan assay recognising all CPV types. This assay will ensure resolution of most diagnostic problems in dogs showing CPV disease shortly after CPV vaccination, although it does not discriminate between field strains and type 2b-based vaccines, recently licensed to market in some countries.

  14. Instituting a Surgical Skills Competition Increases Technical Performance of Surgical Clerkship Students Over Time.

    Science.gov (United States)

    Leraas, Harold J; Cox, Morgan L; Bendersky, Victoria A; Sprinkle, Shanna S; Gilmore, Brian F; Gunasingha, Rathnayaka M; Tracy, Elisabeth T; Sudan, Ranjan

    2017-10-04

    Surgical skills training varies greatly between institutions and is often left to students to approach independently. Although many studies have examined single interventions of skills training, no data currently exists about the implementation of surgical skills assessment as a component of the medical student surgical curriculum. We created a technical skills competition and evaluated its effect on student surgical skill development. Second-year medical students enrolled in the surgery clerkship voluntarily participated in a surgical skills competition consisting of knot tying, laparoscopic peg transfer, and laparoscopic pattern cut. Winning students were awarded dinner with the chair of surgery and a resident of their choice. Individual event times and combined times were recorded and compared for students who completed without disqualification. Disqualification included compromising cutting pattern, dropping a peg out of the field of vision, and incorrect knot tying technique. Timed performance was compared for 2 subsequent academic years using Mann-Whitney U test. Overall, 175 students competed and 71 students met qualification criteria. When compared by academic year, 2015 to 2016 students (n = 34) performed better than 2014 to 2015 students (n = 37) in pattern cut (133s vs 167s, p = 0.040), peg transfer (66s vs 101s, p skills competition improves student technical performance. Further research is needed regarding long-term benefits of surgical competitions for medical students. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  15. Mobile probes

    DEFF Research Database (Denmark)

    Ørngreen, Rikke; Jørgensen, Anna Neustrup; Noesgaard, Signe Schack

    2016-01-01

    A project investigating the effectiveness of a collection of online resources for teachers' professional development used mobile probes as a data collection method. Teachers received questions and tasks on their mobile in a dialogic manner while in their everyday context as opposed...... to in an interview. This method provided valuable insight into the contextual use, i.e. how did the online resource transfer to the work practice. However, the research team also found that mobile probes may provide the scaffolding necessary for individual and peer learning at a very local (intra-school) community...... level. This paper is an initial investigation of how the mobile probes process proved to engage teachers in their efforts to improve teaching. It also highlights some of the barriers emerging when applying mobile probes as a scaffold for learning....

  16. Gastritis cystica profunda recurrence after surgical resection: 2-year follow-up

    Science.gov (United States)

    2014-01-01

    Background Gastritis cystica profunda (GCP) is an uncommon disease characterized by multiple cystic gastric glands within the submucosa of the stomach. Case description Here, we present a case of a 63-year-old man with intermittent epigastric discomfort in whom gastroscopy revealed multiple irregular elevated nodular lesions with smooth surfaces at the anterior of the antrum. Surgical resection of the nodular lesions was performed, and the diagnosis of gastritis cystica profunda (GCP) was confirmed by histological examination. Another elevated nodular lesion approximately 10 mm in diameter with an ulcer was found on the gastric side of the remnant stomach near the resection side from 6 to 24 months after the surgical resection. Endoscopic ultrasonography (EUS) and repeated biopsies of the new elevated lesion were performed. Homogeneous, anechoic masses originating from the submucosa without gastric adenocarcinoma in histological examination showed GCP recurrence may occur. Conclusions We report a case of GCP recurrence within 6 months after surgical resection. GCP should be considered in the differential diagnosis of elevated lesions in the stomach. PMID:24885818

  17. Initial laboratory experience with a novel ultrasound probe for standard and single-port robotic kidney surgery: increasing console surgeon autonomy and minimizing instrument clashing.

    Science.gov (United States)

    Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H

    2012-06-01

    The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Non-surgical treatment of peri-implantitis with the adjunctive use of an 810-nm diode laser

    Directory of Open Access Journals (Sweden)

    Marisa Roncati

    2013-01-01

    Full Text Available An 810-nm diode laser was used to non-surgically treat a 7-mm pocket around an implant that had five threads of bone loss, BoP+, and exudate, and the patient was followed up for 5 years. Non-surgical treatment, home care reinforcement, clinical indices records, and radiographic examination were completed in two consecutive 1-h appointments within 24 h. The patient was monitored frequently for the first 3 months. Subsequently, maintenance debridement visits were scheduled at 3-month intervals. The patient had a decreased probing pocket depth and a negative BoP index compared to initial clinical data, and the results were stable after 1 year. After 5 years of follow-up visits, there appeared to be rebound of the bone level radiographically. Within the limits of this case report, conventional non-surgical periodontal therapy with the adjunctive use of an 810-nm diode laser may be a feasible alternative approach for the management of peri-implantitis. The 5-year clinical and radiographic outcomes indicated maintenance of the clinical improvement.

  19. Imaging optical probe for pressurized steam-water environment

    International Nuclear Information System (INIS)

    Donaldson, M.R.; Pulfrey, R.E.

    1979-01-01

    An air-cooled imaging optical probe, with an outside diameter of 25.4 mm, has been developed to provide high resolution viewing of flow regimes in a steam-water environment at 343 0 C and 15.2 MPa. The design study considered a 3-m length probe. A 0.3-m length probe prototype was fabricated and tested. The optical probe consists of a 3.5-mm diameter optics train surrounded by two coaxial coolant flow channels and two coaxial insulating dead air spaces. With air flowing through the probe at 5.7 g/s, thermal analysis shows that no part of the optics train will exceed 93 0 C when a 3-m length probe is immersed in a 343 0 C environment. Computer stress analysis plus actual tests show that the probe can operate successfully with conservative safety factors. The imaging optical probe was tested five times in the design environment at the semiscale facility at the INEL. Two-phase flow regimes in the high temperature, high pressure, steam-water blowdown and reflood experiments were recorded on video tape for the first time with the imaging optical probe

  20. Design, synthesis and validation of integrin α2β1-targeted probe for microPET imaging of prostate cancer

    International Nuclear Information System (INIS)

    Huang, Chiun-Wei; Li, Zibo; Cai, Hancheng; Chen, Kai; Shahinian, Tony; Conti, Peter S.

    2011-01-01

    The ability of PET to aid in the diagnosis and management of recurrent and/or disseminated metastatic prostate cancer may be enhanced by the development of novel prognostic imaging probes. Accumulating experimental evidence indicates that overexpression of integrin α 2 β 1 may correlate with progression in human prostate cancer. In this study, 64 Cu-labeled integrin α 2 β 1 -targeted PET probes were designed and evaluated for the imaging of prostate cancer. DGEA peptides conjugated with a bifunctional chelator (BFC) were developed to image integrin α 2 β 1 expression with PET in a subcutaneous PC-3 xenograft model. The microPET images were reconstructed by a two-dimensional ordered subsets expectation maximum algorithm. The average radioactivity accumulation within a tumor or an organ was quantified from the multiple region of interest volumes. The PET tracer demonstrated prominent tumor uptake in the PC-3 xenograft (integrin α 2 β 1 -positive). The receptor specificity was confirmed in a blocking experiment. Moreover, the low tracer uptake in a CWR-22 tumor model (negative control) further confirmed the receptor specificity. The sarcophagine-conjugated DGEA peptide allows noninvasive imaging of tumor-associated α 2 β 1 expression, which may be a useful PET probe for evaluating the metastatic potential of prostate cancer. (orig.)

  1. Clinical and histologic evaluation of non-surgical periodontal therapy with enamel matrix derivative: a report of four cases.

    Science.gov (United States)

    Mellonig, James T; Valderrama, Pilar; Gregory, Holly J; Cochran, David L

    2009-09-01

    Enamel matrix derivative (EMD) is a composite of proteins that was demonstrated histologically to work as an adjunct to periodontal regenerative surgical therapy. The purpose of this study was to evaluate the clinical and histologic effects of EMD as an adjunct to scaling and root planing. Four patients with severe chronic periodontitis and scheduled to receive complete dentures were accrued. Probing depth and clinical attachment levels were obtained. Unlimited time was allowed for hand and ultrasonic instrumentation. A notch was placed in the root >or=1 to 2 mm from the apical extent of root planing. EMD was inserted into the pocket, and a periodontal dressing was placed. Patients were seen every 2 weeks for plaque control. At 6 months post-treatment, soft tissue measurements were repeated, and the teeth were removed en bloc and prepared for histomorphologic analysis. Probing depth reduction and clinical attachment level gain were obtained in three-fourths of the specimens. Three of the four specimens analyzed histologically demonstrated new cementum, bone, periodontal ligament, and connective tissue attachment coronal to the notch. In one specimen, the gingival margin had receded below the notch. The results were unexpected and may represent an aberration. However, the substantial reduction in deep probing depths and clinical attachment level gain in three of four specimens, in addition to the histologic findings of new cementum, new bone, a new periodontal ligament, and a new connective tissue attachment, suggest that EMD may be useful as an adjunct to scaling and root planing in single-rooted teeth.

  2. A new fluorescent pyrene–pyridine dithiocarbamate probe: A chemodosimeter to detect Hg{sup 2+} in pure aqueous medium and in live cells

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Vikram; Srivastava, Priyanka [Department of Chemistry, Faculty of Science, Banaras Hindu University, Varanasi-221005 (India); PrakashVerma, Shiv [Centre for Genetic Disorders, Faculty of Science, Banaras Hindu University, Varanasi-221005 (India); Misra, Arvind [Department of Chemistry, Faculty of Science, Banaras Hindu University, Varanasi-221005 (India); Das, Parimal [Centre for Genetic Disorders, Faculty of Science, Banaras Hindu University, Varanasi-221005 (India); Singh, Nanhai, E-mail: nsinghbhu@gmail.com [Department of Chemistry, Faculty of Science, Banaras Hindu University, Varanasi-221005 (India)

    2014-10-15

    A new pyrene–pyridine dithiocarbamate based fluorescent chemodosimeter, potassium (pyren-1-ylmethyl)(pyridin-2-ylmethyl)dithiocarbamate (L1) has been designed and synthesized. The chemodosimeter shows high selectivity and sensitivity (5.2 ppb) for Hg{sup 2+} in pure aqueous medium in which emission intensity was quenched by ≈80% due to the formation of new cyclized species, 1. The probe behaves as a chemodosimeter for Hg{sup 2+} ions and forms Hg{sup 2+} triggered cyclised imidazoline species with approximate detection time of 50 s and exhibits both colorimetric and fluorometric changes on detection of Hg{sup 2+} ion. Color of the probe (L1) changed from green to colorless visible to the naked eye and from green to dark blue upon the addition of Hg{sup 2+} ions under UV light. The Hg{sup 2+} triggered cyclization reaction was confirmed by spectral data analysis and a single crystal structure determination of the cyclised entity 2 obtained from the model compound potassium benzyl(pyridin-2-ylmethyl) dithiocarbamate (L2). L1 finds its application for detection of Hg{sup 2+} ions on paper strips, and in BSA (bovine serum albumin) medium. L1 is also applicable for the monitoring of Hg{sup 2+} ion in NIH3T3 live cells. - Highlights: • Efficient chemodosimeter to detect Hg{sup 2+} ions in pure aqueous medium. • Hg{sup 2+} triggered cyclisation and formation of imidazoline species. • Probe exhibit both colorimetric and fluorometric changes • Probe is applicable to detect Hg{sup 2+} in live cells and on cellulose paper strips.

  3. Accuracy of probing attachment levels using a new computerized cemento-enamel junction probe.

    Science.gov (United States)

    Deepa, R; Prakash, Shobha

    2012-01-01

    The assessment of clinical attachment level (CAL) represents the gold standard for diagnosing and monitoring periodontal disease. The aim of the present study was to evaluate the performance of the newly introduced cemento-enamel junction (CEJ) probe in detecting CAL, using CEJ as a fixed reference point, and to compare the CEJ probe with the Florida stent probe (FSP) as well as with a standard manual probe, University of North Carolina-15 (UNC-15). Three examiners recorded the probing attachment level in 384 sites in case group (chronic periodontitis), and in 176 sites, in control group (healthy periodontal status), using the three probes. Subjects included both the sexes and ranged from 35 to 45 years. The experimental design was structured to balance the intra- and inter-examiner consistency at the same site during the two visits. CEJ probe showed higher intra-and inter-examiner consistency over both FSP and UNC-15 in both the case and control groups. Frequency distribution of differences of various magnitudes of repeated measurements ≤1 mm was in the higher range of 86.8% to 87.5% for CEJ probe. The FSP was more reproducible than UNC-15 in detecting relative attachment level (RAL). CEJ automated probe was found to have greatest potential for accuracy and consistency in detecting CAL than FSP and UNC-15. The automated probes appeared to be more reproducible than manual probes.

  4. The effect of fasting on surgical performance

    DEFF Research Database (Denmark)

    Schefte, David Fenger; Rosenstock, Steffen Jais

    2016-01-01

    BACKGROUND: It is unknown whether fasting has any impact on surgical performance. This simulator-based study investigates whether fasting affects surgical performance. METHODS: Twelve healthy medical students [seven women, mean age 26.5 years (range 23-34)] with no prior experience with surgical...... simulators underwent a short course introduction to the LapSim(®) simulator. After having reached a predefined level, the participants performed five simulated salpingectomies on the LapSim(®) simulator 5-30 days after the initial introduction. The procedures took place at 9 a.m. and 2 p.m. after fasting...... in the longitudinal axis with the left hand. CONCLUSION: The simulator-based study suggests that 17 h of fasting does not deteriorate surgical performance. Further studies on the effect of fasting on surgical performance are needed....

  5. Surgical treatment for medically refractory myasthenic blepharoptosis

    OpenAIRE

    Shimizu, Yusuke; Suzuki,Shigeaki; Nagasao,Tomohisa; Ogata,Hisao; Yazawa,Masaki; Suzuki,Norihiro; Kishi,Kazuo

    2014-01-01

    Yusuke Shimizu,1 Shigeaki Suzuki,2 Tomohisa Nagasao,1 Hisao Ogata,1 Masaki Yazawa,1 Norihiro Suzuki,2 Kazuo Kishi1 1Department of Plastic and Reconstructive Surgery, 2Department of Neurology, Keio University School of Medicine, Tokyo, JapanPurpose: Currently, only a few reports have recommended surgery as a suitable treatment for blepharoptosis associated with myasthenia gravis. The present study aims to introduce our surgical criteria, surgical options, outcomes, and precautions for medicall...

  6. Selective activation of SHP2 activity by cisplatin revealed by a novel chemical probe-based assay

    International Nuclear Information System (INIS)

    Kuo, Chun-Chen; Chu, Chi-Yuan; Lin, Jing-Jer; Lo, Lee-Chiang

    2010-01-01

    Src homology-2 (SH2) domain-containing phosphatase 2 (SHP2) is known to participate in several different signaling pathways to mediate cell growth, survival, migration, and differentiation. However, due to the lack of proper analytical tools, it is unclear whether the phosphatase activity of SHP2 is activated in most studies. We have previously developed an activity-based probe LCL2 that formed covalent linkage with catalytically active protein tyrosine phosphatases (PTPs). Here, by combining LCL2 with a SHP2 specific antibody, we established an assay system that enables the direct monitoring of SHP2 activity upon cisplatin treatment of cancer cells. The protocol is advantageous over conventional colorimetric or in-gel PTP assays as it is specific and does not require the use of radioisotope reagents. Using this assay, we found SHP2 activity was selectively activated by cisplatin. Moreover, the activation of SHP2 appeared to be specific for cisplatin as other DNA damage agents failed to activate the activity. Although the role of SHP2 activation by cisplatin treatments is still unclear to us, our results provide the first direct evidence for the activation of SHP2 during cisplatin treatments. More importantly, the concept of using activity-based probe in conjunction with target-specific antibodies could be extended to other enzyme classes.

  7. Surgical Critical Care Initiative

    Data.gov (United States)

    Federal Laboratory Consortium — The Surgical Critical Care Initiative (SC2i) is a USU research program established in October 2013 to develop, translate, and validate biology-driven critical care....

  8. Pitot-probe displacement in a supersonic turbulent boundary layer

    Science.gov (United States)

    Allen, J. M.

    1972-01-01

    Eight circular pitot probes ranging in size from 2 to 70 percent of the boundary-layer thickness were tested to provide experimental probe displacement results in a two-dimensional turbulent boundary layer at a nominal free-stream Mach number of 2 and unit Reynolds number of 8 million per meter. The displacement obtained in the study was larger than that reported by previous investigators in either an incompressible turbulent boundary layer or a supersonic laminar boundary layer. The large probes indicated distorted Mach number profiles, probably due to separation. When the probes were small enough to cause no appreciable distortion, the displacement was constant over most of the boundary layer. The displacement in the near-wall region decreased to negative displacement in some cases. This near-wall region was found to extend to about one probe diameter from the test surface.

  9. A Direct Comparison of Azide and Nitrile Vibrational Probes

    Science.gov (United States)

    Gai, Xin Sonia; Coutifaris, Basil A.; Brewer, Scott H.; Fenlon, Edward E.

    2011-01-01

    The synthesis of 2′-azido-5-cyano-2′-deoxyuridine, N3CNdU (1), from trityl-protected 2′-amino-2′-deoxyuridine was accomplished in four steps with a 12.5% overall yield. The IR absorption positions and profiles of the azide and nitrile group of N3CNdU were investigated in 14 different solvents and water/DMSO solvent mixtures. The azide probe was superior to the nitrile probe in terms of its extinction coefficient, which is 2–4 times larger. However, the nitrile IR absorbance profile is generally less complicated by accidental Fermi resonance. The IR frequencies of both probes undergo a substantial red shift upon going from water to aprotic solvents such as THF or DMSO. DFT calculations supported the hypothesis that the molecular origin of the higher observed frequency in water is primarily due to hydrogen bonds between the probes and water molecules. PMID:21336362

  10. Provision of general paediatric surgical services in a regional hospital.

    LENUS (Irish Health Repository)

    Zgraj, O

    2012-01-31

    BACKGROUND: In Ireland, specialist paediatric surgery is carried out in paediatric hospitals in Dublin. General surgeons\\/consultants in other surgical specialities provide paediatric surgical care in regional centres. There has been a failure to train general surgeons with paediatric skills to replace these surgeons upon retirement. AIM: To assess paediatric surgical workload in one regional centre to focus the debate regarding the future provision of general paediatric surgery in Ireland. METHODS: Hospital in-patient enquiry (HIPE) system was used to identify total number of paediatric surgical admissions and procedures. Cases assessed requiring hospital transfer. RESULTS: Of 17,478 surgical patients treated, 2,584 (14.8%) were under 14 years. A total of 2,154 procedures were performed. CONCLUSION: Regional centres without dedicated paediatric surgeons deliver care to large numbers of paediatric patients. The demand for care highlights the need for formal paediatric services\\/appropriate surgical training for general surgical trainees.

  11. Comparison of Langmuir probe and multipole resonance probe measurements in argon, hydrogen, nitrogen, and oxygen mixtures in a double ICP discharge

    Science.gov (United States)

    Fiebrandt, Marcel; Oberberg, Moritz; Awakowicz, Peter

    2017-07-01

    The results of a Multipole Resonance Probe (MRP) are compared to a Langmuir probe in measuring the electron density in Ar, H2, N2, and O2 mixtures. The MRP was designed for measurements in industry processes, i.e., coating or etching. To evaluate a possible influence on the MRP measurement due to molecular gases, different plasmas with increasing molecular gas content in a double inductively coupled plasma at 5 Pa and 10 Pa at 500 W are used. The determined electron densities from the MRP and the Langmuir probe slightly differ in H2 and N2 diluted argon plasmas, but diverge significantly with oxygen. In pure molecular gas plasmas, electron densities measured with the MRP are always higher than those measured with the Langmuir Probe, in particular, in oxygen containing mixtures. The differences can be attributed to etching of the tungsten wire in the Ar:O2 mixtures and rf distortion in the pure molecular discharges. The influence of a non-Maxwellian electron energy distribution function, negative ions or secondary electron emission seems to be of no or only minor importance.

  12. Risk-factors for surgical delay following hip fracture.

    Science.gov (United States)

    Sanz-Reig, J; Salvador Marín, J; Ferrández Martínez, J; Orozco Beltrán, D; Martínez López, J F

    To identify pre-operative risk factors for surgical delay of more than 2 days after admission in patients older than 65 years with a hip fracture. A prospective observational study was conducted on 180 hip fractures in patients older than 65 years of age admitted to our hospital from January 2015 to April 2016. The data recorded included, patient demographics, day of admission, pre-fracture comorbidities, mental state, level of mobility and physical function, type of fracture, antiaggregant and anticoagulant medication, pre-operative haemoglobin value, type of treatment, and surgical delay. The mean age of the patients was 83.7 years. The mean Charlson Index was 2.8. The pre-fracture baseline co-morbidities were equal or greater than 2 in 70% of cases. Mean timing of surgery was 3.1 days. At the time of admission, 122 (67.7%) patients were fit for surgery, of which 80 (44.4%) underwent surgery within 2 days. A Charlson index greater than 2, anticoagulant therapy, and admission on Thursday to Saturday, were independently associated with a surgical delay greater than 2 days. The rate of hip fracture patients undergoing surgery within 2 days is low. Risk factors associated to surgical delay are non-modifiable. However, their knowledge should allow the development of protocols that can reduce surgical delay in this group of patients. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. An Evaluation of Preparedness, Delivery and Impact of Surgical and Anesthesia Care in Madagascar: A Framework for a National Surgical Plan.

    Science.gov (United States)

    Bruno, Emily; White, Michelle C; Baxter, Linden S; Ravelojaona, Vaonandianina Agnès; Rakotoarison, Hasiniaina Narindria; Andriamanjato, Hery Harimanitra; Close, Kristin L; Herbert, Alison; Raykar, Nakul; Saluja, Saurabh; Shrime, Mark G

    2017-05-01

    The Lancet Commission on Global Surgery (LCoGS) described the lack of access to safe, affordable, timely surgical, and anesthesia care. It proposed a series of 6 indicators to measure surgery, accompanied by time-bound targets and a template for national surgical planning. To date, no sub-Saharan African country has completed and published a nationwide evaluation of its surgical system within this framework. Mercy Ships, in partnership with Harvard Medical School and the Madagascar Ministry of Health, collected data on the 6 indicators from 22 referral hospitals in 16 out of 22 regions of Madagascar. Data collection was by semi-structured interviews with ministerial, medical, laboratory, pharmacy, and administrative representatives in each region. Microsimulation modeling was used to calculate values for financial indicators. In Madagascar, 29% of the population can access a surgical facility within 2 h. Surgical workforce density is 0.78 providers per 100,000 and annual surgical volume is 135-191 procedures per 100,000 with a perioperative mortality rate of 2.5-3.3%. Patients requiring surgery have a 77.4-86.3 and 78.8-95.1% risk of incurring impoverishing and catastrophic expenditure, respectively. Of the six LCoGS indicator targets, Madagascar meets one, the reporting of perioperative mortality rate. Compared to the LCoGS targets, Madagascar has deficits in surgical access, workforce, volume, and the ability to offer financial risk protection to surgical patients. Its perioperative mortality rate, however, appears better than in comparable countries. The government is committed to improvement, and key stakeholder meetings to create a national surgical plan have begun.

  14. Surgical treatment of gynecomastia: complications and outcomes.

    Science.gov (United States)

    Li, Chun-Chang; Fu, Ju-Peng; Chang, Shun-Cheng; Chen, Tim-Mo; Chen, Shyi-Gen

    2012-11-01

    Gynecomastia is defined as the benign enlargement of the male breast. Multiple surgical options have been used to improve outcomes. The aim of this study was to analyze the surgical approaches to the treatment of gynecomastia and their outcomes over a 10-year period. All patients undergoing surgical correction of gynecomastia in our department between 2000 and 2010 were included for retrospective evaluation. The data were analyzed for etiology, stage of gynecomastia, surgical technique, complications, risk factors, and revision rate. The surgical result was evaluated with self-assessment questionnaires. A total of 41 patients with 75 operations were included. Techniques included subcutaneous mastectomy alone or with additional ultrasound-assisted liposuction (UAL) and isolated UAL. The surgical revision rate for all patients was 4.8%. The skin-sparing procedure gave good surgical results in grade IIb and grade III gynecomastia with low revision and complication rates. The self-assessment report revealed a good level of overall satisfaction and improvement in self-confidence (average scores 9.4 and 9.2, respectively, on a 10-point scale). The treatment of gynecomastia requires an individualized approach. Subcutaneous mastectomy combined with UAL could be used as the first choice for surgical treatment of grade II and III gynecomastia.

  15. Developing antiviral surgical gown using nonwoven fabrics for ...

    African Journals Online (AJOL)

    Objectives: To develop antiviral surgical gown comprising of Polypropylene nonwoven as outer layer, Polytetrafluroethylene (PTFE) film as middle layer and polyester nonwoven as inner layer and the surgical gown with a basic weight of 70 g/m2. Methods: The titanium dioxide (TiO2) nano dispersion was prepared with ...

  16. The semi-conductor detectors: art state, new concepts

    International Nuclear Information System (INIS)

    Pochet, T.

    1993-01-01

    After a brief recall of signal formation principle in a detector and of its different operation modes, the high Z materials as CdTe, HgI 2 , GaAs ,Ge and Si are presented, followed by the new 'thin layer' semiconductors

  17. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an adhesive tape solvent is a device that consists of a liquid such as 1,1,2-trichloro-1,2,2-trifluoroethane...

  18. Comprehensive Surgical Coaching Enhances Surgical Skill in the Operating Room: A Randomized Controlled Trial.

    Science.gov (United States)

    Bonrath, Esther M; Dedy, Nicolas J; Gordon, Lauren E; Grantcharov, Teodor P

    2015-08-01

    The aim of the study was to determine whether individualized coaching improved surgical technical skill in the operating room to a higher degree than current residency training. Clinical training in the operating room is a valuable opportunity for surgeons to acquire skill and knowledge; however, it often remains underutilized. Coaching has been successfully used in various industries to enhance performance, but its role in surgery has been insufficiently investigated. This randomized controlled trial was conducted at one surgical training program. Trainees undergoing a minimally invasive surgery rotation were randomized to either conventional training (CT) or comprehensive surgical coaching (CSC). CT included ward and operating room duties, and regular departmental teaching sessions. CSC comprised performance analysis, debriefing, feedback, and behavior modeling. Primary outcome measures were technical performance as measured on global and procedure-specific rating scales, and surgical safety parameters, measured by error count. Operative performance was assessed by blinded video analysis of the first and last cases recorded by the participants during their rotation. Twenty residents were randomized and 18 completed the study. At posttraining the CSC group (n = 9) scored significantly higher on a procedure-specific skill scale compared with the CT group (n = 9) [median, 3.90 (interquartile range, 3.68-4.30) vs 3.60 (2.98-3.70), P = 0.017], and made fewer technical errors [10 (7-13) vs 18 (13-21), P = 0.003]. Significant within-group improvements for all skill metrics were only noted in the CSC group. Comprehensive surgical coaching enhances surgical training and results in skill acquisition superior to conventional training.

  19. Intra-Operative Inspired Fraction of Oxygen and the Risk of Surgical Site Infections in Patients with Type 1 Surgical Incisions.

    Science.gov (United States)

    Wanta, Brendan T; Hanson, Kristine T; Hyder, Joseph A; Stewart, Thomas M; Curry, Timothy B; Berbari, Elie F; Habermann, Elizabeth B; Kor, Daryl J; Brown, Michael J

    2018-04-02

    Whether the fraction of inspired oxygen (F I O 2 ) influences the risk of surgical site infection (SSI) is controversial. The World Health Organization and the World Federation of Societies of Anesthesiologists offer conflicting recommendations. In this study, we evaluate simultaneously three different definitions of F I O 2 exposure and the risk of SSI in a large surgical population. Patients with clean (type 1) surgical incisions who developed superficial and deep organ/space SSI within 30 days after surgery from January 2003 through December 2012 in five surgical specialties were matched to specialty-specific controls. Fraction of inspired oxygen exposure was defined as (1) nadir F I O 2 , (2) percentage of operative time with F I O 2 greater than 50%, and (3) cumulative hyperoxia exposure, calculated as the area under the curve (AUC) of F I O 2 by time for the duration in which F I O 2 greater than 50%. Stratified univariable and multivariable logistic regression models tested associations between F I O 2 and SSI. One thousand two hundred fifty cases of SSI were matched to 3,248 controls. Increased oxygen exposure, by any of the three measures, was not associated with the outcome of any SSI in a multivariable logistic regression model. Elevated body mass index (BMI; 35+ vs. operative oxygen exposure was associated with higher odds of SSI in the neurosurgical and spine populations. Increased intra-operative inspired fraction of oxygen was not associated with a reduction in SSI. These findings do not support the practice of increasing F I O 2 for the purpose of SSI reduction in patients with clean surgical incisions.

  20. Highly selective and rapidly responsive fluorescent probe for hydrogen sulfide detection in wine.

    Science.gov (United States)

    Wang, Hao; Wang, Jialin; Yang, Shaoxiang; Tian, Hongyu; Liu, Yongguo; Sun, Baoguo

    2018-08-15

    A new fluorescent probe 6-(2, 4-dinitrophenoxy)-2-naphthonitrile (probe 1) was designed and synthesized for the selective detection of hydrogen sulfide (H 2 S). The addition of H 2 S to a solution of probe 1 resulted in a marked fluorescence turn-on alongside a visual color change from colorless to light yellow. Importantly, this distinct color response indicated that probe 1 could be used as a visual sensor for H 2 S. Moreover, probe 1 was successfully used as a signal tool to determine the H 2 S levels in beer and red wine. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Probe Storage

    NARCIS (Netherlands)

    Gemelli, Marcellino; Abelmann, Leon; Engelen, Johannes Bernardus Charles; Khatib, M.G.; Koelmans, W.W.; Zaboronski, Olog; Campardo, Giovanni; Tiziani, Federico; Laculo, Massimo

    2011-01-01

    This chapter gives an overview of probe-based data storage research over the last three decades, encompassing all aspects of a probe recording system. Following the division found in all mechanically addressed storage systems, the different subsystems (media, read/write heads, positioning, data

  2. TORE SUPRA fast reciprocating radio frequency probe (abstract)

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.; Kwon, M.; Goulding, R.H.; Hoffman, D.J.; Saoutic, B.; Becoulet, A.; Fraboulet, D.; Beaumont, B.; Kuus, H.; Ladurelle, L.; Pascal, J.Y.

    1995-01-01

    A fast reciprocating ion cyclotron range of frequencies (ICRF) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at Oak Ridge National Laboratory. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal rf magnetic fields and the other senses poloidal rf magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/s) of 30 cm and a fast stroke (1.5 m/s) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition, and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data show parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  3. Open surgical simulation--a review.

    Science.gov (United States)

    Davies, Jennifer; Khatib, Manaf; Bello, Fernando

    2013-01-01

    Surgical simulation has benefited from a surge in interest over the last decade as a result of the increasing need for a change in the traditional apprentice model of teaching surgery. However, despite the recent interest in surgical simulation as an adjunct to surgical training, most of the literature focuses on laparoscopic, endovascular, and endoscopic surgical simulation with very few studies scrutinizing open surgical simulation and its benefit to surgical trainees. The aim of this review is to summarize the current standard of available open surgical simulators and to review the literature on the benefits of open surgical simulation. Open surgical simulators currently used include live animals, cadavers, bench models, virtual reality, and software-based computer simulators. In the current literature, there are 18 different studies (including 6 randomized controlled trials and 12 cohort studies) investigating the efficacy of open surgical simulation using live animal, bench, and cadaveric models in many surgical specialties including general, cardiac, trauma, vascular, urologic, and gynecologic surgery. The current open surgical simulation studies show, in general, a significant benefit of open surgical simulation in developing the surgical skills of surgical trainees. However, these studies have their limitations including a low number of participants, variable assessment standards, and a focus on short-term results often with no follow-up assessment. The skills needed for open surgical procedures are the essential basis that a surgical trainee needs to grasp before attempting more technical procedures such as laparoscopic procedures. In this current climate of medical practice with reduced hours of surgical exposure for trainees and where the patient's safety and outcome is key, open surgical simulation is a promising adjunct to modern surgical training, filling the void between surgeons being trained in a technique and a surgeon achieving fluency in that

  4. Development and inter-laboratory validation of unlabeled probe melting curve analysis for detection of JAK2 V617F mutation in polycythemia vera.

    Science.gov (United States)

    Wu, Zhiyuan; Yuan, Hong; Zhang, Xinju; Liu, Weiwei; Xu, Jinhua; Zhang, Wei; Guan, Ming

    2011-01-01

    JAK2 V617F, a somatic point mutation that leads to constitutive JAK2 phosphorylation and kinase activation, has been incorporated into the WHO classification and diagnostic criteria of myeloid neoplasms. Although various approaches such as restriction fragment length polymorphism, amplification refractory mutation system and real-time PCR have been developed for its detection, a generic rapid closed-tube method, which can be utilized on routine genetic testing instruments with stability and cost-efficiency, has not been described. Asymmetric PCR for detection of JAK2 V617F with a 3'-blocked unlabeled probe, saturate dye and subsequent melting curve analysis was performed on a Rotor-Gene® Q real-time cycler to establish the methodology. We compared this method to the existing amplification refractory mutation systems and direct sequencing. Hereafter, the broad applicability of this unlabeled probe melting method was also validated on three diverse real-time systems (Roche LightCycler® 480, Applied Biosystems ABI® 7500 and Eppendorf Mastercycler® ep realplex) in two different laboratories. The unlabeled probe melting analysis could genotype JAK2 V617F mutation explicitly with a 3% mutation load detecting sensitivity. At level of 5% mutation load, the intra- and inter-assay CVs of probe-DNA heteroduplex (mutation/wild type) covered 3.14%/3.55% and 1.72%/1.29% respectively. The method could equally discriminate mutant from wild type samples on the other three real-time instruments. With a high detecting sensitivity, unlabeled probe melting curve analysis is more applicable to disclose JAK2 V617F mutation than conventional methodologies. Verified with the favorable inter- and intra-assay reproducibility, unlabeled probe melting analysis provided a generic mutation detecting alternative for real-time instruments.

  5. Development and inter-laboratory validation of unlabeled probe melting curve analysis for detection of JAK2 V617F mutation in polycythemia vera.

    Directory of Open Access Journals (Sweden)

    Zhiyuan Wu

    Full Text Available BACKGROUND: JAK2 V617F, a somatic point mutation that leads to constitutive JAK2 phosphorylation and kinase activation, has been incorporated into the WHO classification and diagnostic criteria of myeloid neoplasms. Although various approaches such as restriction fragment length polymorphism, amplification refractory mutation system and real-time PCR have been developed for its detection, a generic rapid closed-tube method, which can be utilized on routine genetic testing instruments with stability and cost-efficiency, has not been described. METHODOLOGY/PRINCIPAL FINDINGS: Asymmetric PCR for detection of JAK2 V617F with a 3'-blocked unlabeled probe, saturate dye and subsequent melting curve analysis was performed on a Rotor-Gene® Q real-time cycler to establish the methodology. We compared this method to the existing amplification refractory mutation systems and direct sequencing. Hereafter, the broad applicability of this unlabeled probe melting method was also validated on three diverse real-time systems (Roche LightCycler® 480, Applied Biosystems ABI® 7500 and Eppendorf Mastercycler® ep realplex in two different laboratories. The unlabeled probe melting analysis could genotype JAK2 V617F mutation explicitly with a 3% mutation load detecting sensitivity. At level of 5% mutation load, the intra- and inter-assay CVs of probe-DNA heteroduplex (mutation/wild type covered 3.14%/3.55% and 1.72%/1.29% respectively. The method could equally discriminate mutant from wild type samples on the other three real-time instruments. CONCLUSIONS: With a high detecting sensitivity, unlabeled probe melting curve analysis is more applicable to disclose JAK2 V617F mutation than conventional methodologies. Verified with the favorable inter- and intra-assay reproducibility, unlabeled probe melting analysis provided a generic mutation detecting alternative for real-time instruments.

  6. Femtosecond Pump-Push-Probe and Pump-Dump-Probe Spectroscopy of Conjugated Polymers: New Insight and Opportunities.

    Science.gov (United States)

    Kee, Tak W

    2014-09-18

    Conjugated polymers are an important class of soft materials that exhibit a wide range of applications. The excited states of conjugated polymers, often referred to as excitons, can either deactivate to yield the ground state or dissociate in the presence of an electron acceptor to form charge carriers. These interesting properties give rise to their luminescence and the photovoltaic effect. Femtosecond spectroscopy is a crucial tool for studying conjugated polymers. Recently, more elaborate experimental configurations utilizing three optical pulses, namely, pump-push-probe and pump-dump-probe, have been employed to investigate the properties of excitons and charge-transfer states of conjugated polymers. These studies have revealed new insight into femtosecond torsional relaxation and detrapping of bound charge pairs of conjugated polymers. This Perspective highlights (1) the recent achievements by several research groups in using pump-push-probe and pump-dump-probe spectroscopy to study conjugated polymers and (2) future opportunities and potential challenges of these techniques.

  7. Hard probes 2006 Asilomar

    CERN Multimedia

    2006-01-01

    "The second international conference on hard and electromagnetic probes of high-energy nuclear collisions was held June 9 to 16, 2006 at the Asilomar Conference grounds in Pacific Grove, California" (photo and 1/2 page)

  8. Intraoperative navigation of an optically tracked surgical robot.

    Science.gov (United States)

    Cornellà, Jordi; Elle, Ole Jakob; Ali, Wajid; Samset, Eigil

    2008-01-01

    This paper presents an adaptive control scheme for improving the performance of a surgical robot when it executes tasks autonomously. A commercial tracking system is used to correlate the robot with the preoperative plan as well as to correct the position of the robot when errors between the real and planned positions are detected. Due to the noisy signals provided by the tracking system, a Kalman filter is proposed to smooth the variations and to increase the stability of the system. The efficiency of the approach has been validated using rigid and flexible endoscopic tools, obtaining in both cases that the target points can be reached with an error less than 1mm. These results make the approach suitable for a range of abdominal procedures, such as autonomous repositioning of endoscopic tools or probes for percutaneous procedures.

  9. Anxiety in veterinary surgical students

    DEFF Research Database (Denmark)

    Langebæk, Rikke; Eika, Berit; Jensen, Asger Lundorff

    2012-01-01

    The surgical educational environment is potentially stressful and this can negatively affect students' learning. The aim of this study was to investigate whether veterinary students' level of anxiety is higher in a surgical course than in a non-surgical course and if pre-surgical training...... in a Surgical Skills Lab (SSL) has an anxiety reducing effect. Investigations were carried out as a comparative study and a parallel group study. Potential participants were fourth-year veterinary students who attended a surgical course (Basic Surgical Skills) and a non-surgical course (Clinical Examination...... and 28 students from 2010). Our results show that anxiety levels in veterinary students are significantly higher in a surgical course than in a non-surgical course (p...

  10. Advantages of the first-derivative probe technique over the three- and four-parameter probe techniques in fusion plasmas diagnostics

    Czech Academy of Sciences Publication Activity Database

    Hasan, E.; Dimitrova, Miglena; Popov, T.; Ivanova, P.; Dejarnac, Renaud; Stöckel, Jan; Pánek, Radomír

    2018-01-01

    Roč. 13, č. 4 (2018), č. článku P04005. ISSN 1748-0221 R&D Projects: GA MŠk(CZ) LM2015045 Institutional support: RVO:61389021 Keywords : Plasma potential * electron temperature * bi-Maxwellian EEDF * Divertor Langmuir probes * three- and four-parameter probe techniques * first-derivative probe technique Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/13/04/P04005/meta

  11. The Virtual Surgical Pelvis : Anatomy Visualization for Education and Surgical Planning

    NARCIS (Netherlands)

    Smit, N.N.

    2016-01-01

    This thesis deals with visualizing anatomical data for medical education and surgical planning purposes. To this end, we have developed a detailed virtual atlas, the Virtual Surgical Pelvis (VSP),which unifies surgically relevant knowledge on pelvic anatomy. We provide methods to share the knowledge

  12. Surgical site infection among patients undergone orthopaedic ...

    African Journals Online (AJOL)

    Surgical site infection among patients undergone orthopaedic surgery at Muhimbili Orthopaedic Institute, Dar es Salaam, Tanzania. ... of surgical site infection at Muhimbili Orthopedic Institute was high. This was associated with more than 2 hours length of surgery, lack of prophylaxis use, and pre-operative hospital stay.

  13. Deriving DICOM surgical extensions from surgical workflows

    Science.gov (United States)

    Burgert, O.; Neumuth, T.; Gessat, M.; Jacobs, S.; Lemke, H. U.

    2007-03-01

    The generation, storage, transfer, and representation of image data in radiology are standardized by DICOM. To cover the needs of image guided surgery or computer assisted surgery in general one needs to handle patient information besides image data. A large number of objects must be defined in DICOM to address the needs of surgery. We propose an analysis process based on Surgical Workflows that helps to identify these objects together with use cases and requirements motivating for their specification. As the first result we confirmed the need for the specification of representation and transfer of geometric models. The analysis of Surgical Workflows has shown that geometric models are widely used to represent planned procedure steps, surgical tools, anatomical structures, or prosthesis in the context of surgical planning, image guided surgery, augmented reality, and simulation. By now, the models are stored and transferred in several file formats bare of contextual information. The standardization of data types including contextual information and specifications for handling of geometric models allows a broader usage of such models. This paper explains the specification process leading to Geometry Mesh Service Object Pair classes. This process can be a template for the definition of further DICOM classes.

  14. First results on a laser-heated emissive probe

    International Nuclear Information System (INIS)

    Madani, R.; Klinger, T.; Ionita, C.; Schrittwieser, R.

    2004-01-01

    The floating potential V(fl,em) of a probe, emitting a sufficiently high electron current, yields a fairly accurate approximation of Φ(pl). This is an advantage in comparison to the conventional Langmuir probe where, after determination of the electron temperature T e , the plasma potential can only be derived indirectly from the formula Φ(pl) = V(fl) + α*T e , where α is a function of the ratio of the electron to the ion saturation currents (α is around 2.4 in a magnetized hydrogen plasma). In addition, an emissive probe also works if there are electron drifts or beams in the plasma. Emissive probes are usually realised by small directly heated loops of W-wire. Drawbacks of this design are the limited lifetime, the low electron emissivity of W and the voltage drop across the wire. We have developed a new type of emissive probe, which is heated by an infrared high-power diode laser with a maximum output power of 50 W. The probe consists of a small cylinder of LaB 6 . The probe was inserted into the edge region of the VINETA helicon discharge plasma. Basic features of emissive probes were checked. (authors)

  15. Thioglycolic acid-capped CuInS{sub 2}/ZnS quantum dots as fluorescent probe for cobalt ion detection

    Energy Technology Data Exchange (ETDEWEB)

    Zi, Lili; Huang, Yu [Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, 4 Tongjia Lane, Gulou District, Nanjing 210009 (China); Department of Analytical Chemistry, China Pharmaceutical University, 24 Tongjia Lane, Gulou District, Nanjing 210009 (China); Yan, Zhengyu, E-mail: yanzhengyujiang@126.com [Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, 4 Tongjia Lane, Gulou District, Nanjing 210009 (China); Department of Analytical Chemistry, China Pharmaceutical University, 24 Tongjia Lane, Gulou District, Nanjing 210009 (China); Liao, Shenghua, E-mail: liaoshenghuacpu@hotmail.com [Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, 4 Tongjia Lane, Gulou District, Nanjing 210009 (China); Department of Analytical Chemistry, China Pharmaceutical University, 24 Tongjia Lane, Gulou District, Nanjing 210009 (China)

    2014-04-15

    A novel sensing fluorescent probe based on the fluorescence quenching of the thioglycolic acid-capped CuInS{sub 2}/ZnS quantum dots (CuInS{sub 2}/ZnS/TGA QDs) was established for cobalt ions detection. The fluorescence quenching of CuInS{sub 2}/ZnS/TGA QDs was due to the increasing surface deficiency and the inner-filter effect, which were attributed to the reaction between Co{sup 2+} and sulfur bonds on the surface of QDs. The quenching curve could be fitted by a typical Stern–Volmer-type equation, with a linear relationship between the quenching efficiency and the concentration of cobalt ions in the range of 0.3012–90.36 μmol L{sup −1}. And the detection limit (S/N=3) for Co{sup 2+} was 0.16 μmol L{sup −1}. Therefore, the established probe provided a simple, rapid, cheap and sensitive method for Co{sup 2+} detection. In a word, this method can be used to detect Co{sup 2+} in the environment. -- Highlights: • The CuInS2/ZnS QDs were used for the first time as a fluorescent probe for Co{sup 2+} detection. • The dramatic color change could be observed when Co{sup 2+} was added into the QDs solution. • The quenching of QDs was due to the increasing surface deficiency and the inner-filter effect. • This rapid, cheap and sensitive method was applied to the detection of Co{sup 2+} in simulated water.

  16. Thermodynamics of poly(7-methoxy-2-acetylbenzofurane methyl methacrylate-co-styrene) and poly(2-acetylbenzofurane methyl methacrylate-co-styrene)-probe interactions at different temperatures by inverse gas chromatography

    International Nuclear Information System (INIS)

    İlter, Zülfiye; Demir, Abdullah; Kaya, İsmet

    2016-01-01

    Highlights: • Thermodynamic of methacrylate-co-styrene polymers were studied by the inverse gas chromatography. • The sorption parameters of polymer-solute systems were determined under glass transition temperature of polymers. • The solubility parameter (δ 2 ) of the polymer was obtained from the slope and intercepts. • Flory-Huggins interaction parameter (χ 12 ∞ ) were determined for polymer-solute systems. - Abstract: In this study, some thermodynamic properties of poly(7-methoxy-2-acetylbenzofurane methyl methacrylate-co-styrene) Poly(MABMM-co-St) and poly(2-acetylbenzofurane methyl methacrylate-co-styrene) Poly(ABMM-co-St) were studied by the inverse gas chromatography (IGC) technique. The retention times (t r ) of selected organic probes were determined from the interactions with Poly(MABMM-co-St) and Poly(ABMM-co-St) of four groups of solvents with different chemical natures and polarities. Then, specific volume (V g 0 ) values of probes were calculated at different column temperatures. The glass transition temperatures (T g ) of Poly(MABMM-co-St) and Poly(ABMM-co-St) were found as 393, 413 K from inverse gas chromatography measurements, respectively. Under the glass transition temperatures adsorption heat (ΔH a ) and above the glass transition molar heat (ΔH 1 S ), free energies (ΔG 1 S ) and entropies (ΔS 1 S ) belonging to sorption for every probe were calculated from inverse gas chromatography measurements. The partial molar heat (ΔH 1 ∞ ), partial molar free energy (ΔG 1 ∞ ), Flory-Huggins interaction parameter (χ 12 ∞ ) and weight fraction activity coefficient (a 1 /w 1 ) ∞ , values for infinite dilute solutions were calculated for polymer-probe systems. The solubility parameter (δ 2 ) of the polymer was obtained from the slope and intercepts of Flory-Huggins interaction parameter (χ 12 ∞ ) graphs with solubility parameters (δ 1 ) of probes.

  17. A highly selective and sensitive photoswitchable fluorescent probe for Hg2+ based on bisthienylethene-rhodamine 6G dyad and for live cells imaging.

    Science.gov (United States)

    Xu, Li; Wang, Sheng; Lv, Yingnian; Son, Young-A; Cao, Derong

    2014-07-15

    A new photochromic diarylethene derivative bearing rhodamine 6G dimmer as a fluorescent molecular probe is designed and synthesized successfully. All the compounds are characterized by nuclear magnetic resonance and mass spectrometry. The bisthienylethene-rhodamine 6G dyad exhibit excellent phtochromism with reversibly color and fluorescence changes alternating irradiation with ultraviolet and visible light. Upon addition of Hg(2+), its color changes from colorless to red and its fluorescence is remarkably enhanced. Whereas other ions including K(+), Na(+), Ca(2+), Mg(2+), Fe(2+), Co(2+), Ni(2+), Cu(2+), Zn(2+), Mn(2+), Pb(2+), Ni(2+), Fe(3+), Al(3+), Cr(3+) and so on induce basically no spectral changes, which constitute a highly selective and sensitive photoswitchable fluorescent probe toward Hg(2+). Furthermore, by means of laser confocal scanning microscopy experiments, it is demonstrated that this probe can be applied for live cell imaging and monitoring Hg(2+) in living lung cancer cells with satisfying results, which shows its value of potential application in environmental and biological systems. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Evaluation of surgical treatment in mandibular condyle fractures.

    Science.gov (United States)

    Vesnaver, Aleš; Ahčan, Uroš; Rozman, Janez

    2012-12-01

    In the past, fractures of the mandibular condylar process were, as a rule, treated conservatively. At the Department of Maxillofacial and Oral Surgery of the University Medical Centre Ljubljana, Slovenia, our doctrine was changed in 2002 on the basis of preliminary results and reports in the literature, and these fractures were started to be treated surgically by open reduction and internal fixation with miniplates and screws, which led to good results and a shorter rehabilitation period. The goal of this study was to determine the safety and efficiency of surgical treatment, as well as to compare long-term results of surgical and conservative treatment, as objectively as possible. Two groups of patients, which had all sustained a unilateral, extra-articular mandibular condyle fracture, were compared. In the test group, there were 42 surgically treated patients, and in the control group, 20 conservatively treated patients. Clinical parameters and X-ray images were assessed in both groups and compared by the two tailed Student t test, and in case of attributive variables by the χ(2) test. Within the surgically treated group, postoperative and intraoperative complications were noted: temporary facial nerve palsy, development of a parotid salivary fistula, disturbance of auricle sensibility due to injury of the greater auricular nerve, miniplate fracture, as well as intraoperative bleeding, postoperative haematoma formation, infection, reoperation due to fragment malposition and other complications. Postoperative scars were also assessed. Statistically significant differences between the surgically and conservatively treated patients were found when comparing clinical parameters as well as X-ray images, the results being better in the surgically treated group. Complications of surgical treatment were also noted, the most important among them temporary paresis of facial nerve branches, which occurred in 10 patients (24%). Plate fractures occurred in five patients (12

  19. Anatomy of a defective barrier: sequential glove leak detection in a surgical and dental environment.

    Science.gov (United States)

    Albin, M S; Bunegin, L; Duke, E S; Ritter, R R; Page, C P

    1992-02-01

    a) To determine the frequency of perforations in latex surgical gloves before, during, and after surgical and dental procedures; b) to evaluate the topographical distribution of perforations in latex surgical gloves after surgical and dental procedures; and c) to validate methods of testing for latex surgical glove patency. Multitrial tests under in vitro conditions and a prospective sequential patient study using consecutive testing. An outpatient dental clinic at a university dental school, the operating suite in a medical school affiliated with the Veteran's Hospital, and a biomechanics laboratory. Surgeons, scrub nurses, and dental technicians participating in 50 surgical and 50 dental procedures. We collected 679 latex surgical gloves after surgical procedures and tested them for patency by using a water pressure test. We also employed an electronic glove leak detector before donning, after sequential time intervals, and upon termination of 47 surgical (sequential surgical), 50 dental (sequential dental), and in three orthopedic cases where double gloving was used. The electronic glove leak detector was validated by using electronic point-by-point surface probing, fluorescein dye diffusion, as well as detecting glove punctures made with a 27-gauge needle. The random study indicated a leak rate of 33.0% (224 out of 679) in latex surgical gloves; the sequential surgical study demonstrated patency in 203 out of 347 gloves (58.5%); the sequential dental study showed 34 leaks in the 106 gloves used (32.1%); and with double gloving, the leak rate decreased to 25.0% (13 of 52 gloves tested). While the allowable FDA defect rate for unused latex surgical gloves is 1.5%, we noted defect rates in unused gloves of 5.5% in the sequential surgical, 1.9% in the sequential dental, and 4.0% in our electronic glove leak detector validating study. In the sequential surgical study, 52% of the leaks had occurred by 75 mins, and in the sequential dental study, 75% of the leaks

  20. The methodological quality of systematic reviews comparing temporomandibular joint disorder surgical and non-surgical treatment

    Directory of Open Access Journals (Sweden)

    Vasconcelos Belmiro CE

    2008-09-01

    Full Text Available Abstract Background Temporomandibular joint disorders (TMJD are multifactor, complex clinical problems affecting approximately 60–70% of the general population, with considerable controversy about the most effective treatment. For example, reports claim success rates of 70% and 83% for non-surgical and surgical treatment, whereas other reports claim success rates of 40% to 70% for self-improvement without treatment. Therefore, the purpose of this study was to (1 identify systematic reviews comparing temporomandibular joint disorder surgical and non-surgical treatment, (2 evaluate their methodological quality, and (3 evaluate the evidence grade within the systematic reviews. Methods A search strategy was developed and implemented for MEDLINE, Cochrane Library, LILACS, and Brazilian Dentistry Bibliography databases. Inclusion criteria were: systematic reviews (± meta-analysis comparing surgical and non-surgical TMJD treatment, published in English, Spanish, Portuguese, Italian, or German between the years 1966 and 2007(up to July. Exclusion criteria were: in vitro or animal studies; narrative reviews or editorials or editorial letters; and articles published in other languages. Two investigators independently selected and evaluated systematic reviews. Three different instruments (AMSTAR, OQAQ and CASP were used to evaluate methodological quality, and the results averaged. The GRADE instrument was used to evaluate the evidence grade within the reviews. Results The search strategy identified 211 reports; of which 2 were systematic reviews meeting inclusion criteria. The first review met 23.5 ± 6.0% and the second met 77.5 ± 12.8% of the methodological quality criteria (mean ± sd. In these systematic reviews between 9 and 15% of the trials were graded as high quality, and 2 and 8% of the total number of patients were involved in these studies. Conclusion The results indicate that in spite of the widespread impact of TMJD, and the multitude of

  1. Regenerative surgical therapy for peri-implantitis using deproteinized bovine bone mineral with 10% collagen, enamel matrix derivative and Doxycycline-A prospective 3-year cohort study.

    Science.gov (United States)

    Mercado, Faustino; Hamlet, Stephen; Ivanovski, Saso

    2018-05-16

    There is limited evidence regarding the long-term efficacy of regenerative treatment for peri-implantitis. The aim of this study was to evaluate a combination therapy of deproteinized bovine bone mineral with 10% collagen (DBBMC), enamel matrix derivative (EMD) and Doxycycline in the regeneration of bone defects associated with peri-implantitis. Thirty patients diagnosed with peri-implantitis (BoP/suppuration, probing depth greater than 4 mm, minimum radiographic bone loss of 20%, at least 2 years in function) were enrolled in the study. Clinical measurements included probing depths, recession, radiographic bone fill, gingival inflammation and bleeding on probing/suppuration. Following surgical access and debridement, the implant surfaces were decontaminated with 24% EDTA for 2 min, and the bone defects were filled with a combined mixture of DBBMC, EMD and Doxycycline powder. The defects were covered with connective tissue grafts where necessary. Clinical measurements were recorded after 12, 24 and 36 months. The mean probing depth and bone loss at the initial visit was 8.9 mm (±1.9) and 6.92 mm (±1.26), respectively. Both mean probing depth and bone loss reduced significantly from baseline to 3.55 mm (±0.50) and 2.85 mm (±0.73) at 12 months, 3.50 (±0.50) and 2.62 mm (±0.80) at 24 months and 3.50 mm (±0.50) and 2.60 mm (±0.73) at 36 months. 56.6% of the implants were considered successfully treated (according to Successful Treatment Outcome Criterion: PD 10%, no BoP/suppuration, no recession >0.5 mm for anterior implants and >1.5 mm for posterior implants) after 36 months. Regenerative treatment of peri-implantitis using a combined mixture of DBBMC, EMD and Doxycycline achieved promising results. The benefits of this protocol incorporating EMD should be tested in randomized clinical trials. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Highly selective and sensitive detection of Cu2+ with lysine enhancing bovine serum albumin modified-carbon dots fluorescent probe.

    Science.gov (United States)

    Liu, Jia-Ming; Lin, Li-ping; Wang, Xin-Xing; Lin, Shao-Qin; Cai, Wen-Lian; Zhang, Li-Hong; Zheng, Zhi-Yong

    2012-06-07

    Based on the ability of lysine (Lys) to enhance the fluorescence intensity of bovine serum albumin modified-carbon dots (CDs-BSA) to decrease surface defects and quench fluorescence of the CDs-BSA-Lys system in the presence of Cu(2+) under conditions of phosphate buffer (PBS, pH = 5.0) at 45 °C for 10 min, a sensitive Lys enhancing CDs-BSA fluorescent probe was designed. The environment-friendly, simple, rapid, selective and sensitive fluorescent probe has been utilized to detect Cu(2+) in hair and tap water samples and it achieved consistent results with those obtained by inductively coupled plasma mass spectroscopy (ICP-MS). The mechanism of the proposed assay for the detection of Cu(2+) is discussed.

  3. Effects of some salts on H2O as probed by a thermodynamic signature of glycerol: towards understanding the Hofmeister effects (VII)

    DEFF Research Database (Denmark)

    Koga, Yoshikata; Westh, Peter

    2014-01-01

    . Namely, we devised a methodology whereby the effect of an ion on H2O is characterized by two orthogonal indices, hydrophobicity and hydrophilicity, by using a third order thermodynamic signature of hydrophobic 1-propanol (1P) as a probe, the 1P-probing methodology. The results indicated that the common...

  4. Surgical treatment of buried penis.

    Science.gov (United States)

    Lipszyc, E; Pfister, C; Liard, A; Mitrofanoff, P

    1997-10-01

    The buried penis is a rare congenital entity, whose treatment is surgical. There are few publications concerning this matter. The authors report on their experience in 10 cases (1990-1995). In this abnormality, the tip of the glans does not project from the pubic or scrotal skin. It is due to: 1) an excessive development of the penile fascia which retracts the penis; 2) insufficient attachment of the penile skin at the base of the penis; 3) often excessive prepubic fat worsens the appearance of the abnormality but does not by itself totally explain it; 4) a tight phimosis is often present. Surgical treatment is necessary because this aspect tends to persist even after puberty. One cannot indeed count on the development at the age of puberty, neither on the diminution of the fat, nor on the simple cure of the phimosis. One must above all ban circumcision which causes the risk of eliminating the skin necessary for reconstruction. The surgical procedure will comprise: 1) a longitudinal dorsal incision extended circumferentially; 2) resection of the thickened fascia penis; 3) anchoring of the deep face of the dermis to the proximal part of the fascia penis at the base of the penis. This surgical procedure has always brought a significant improvement to the appearance of the penis.

  5. The surgical management of the rheumatoid spine: Has the evolution of surgical intervention changed outcomes?

    Directory of Open Access Journals (Sweden)

    Robin Bhatia

    2014-01-01

    Full Text Available Context: Surgery for the rheumatoid cervical spine has been shown to stabilize the unstable spine; arrest/improve the progression of neurological deficit, help neck pain, and possibly decelerate the degenerative disease process. Operative intervention for the rheumatoid spine has significantly changed over the last 30 years. Aims: The purpose of this study was to review all cases of cervical rheumatoid spine requiring surgical intervention in a single unit over the last 30 years. Materials and Methods: A prospectively-maintained spine database was retrospectively searched for all cases of rheumatoid spine, leading to a review of indications, imaging, Ranawat and Myelopathy Disability Index measures, surgical morbidity, and survival curve analysis. Results: A total of 224 cases were identified between 1981 and 2011. Dividing the data into three time-epochs, there has been a significant increase in the ratio of segment-saving Goel-Harms C1-C2: Occipitocervical fixation (OCF surgery and survival has increased between 1981 and 2011 from 30% to 51%. Patients undergoing C1-C2 fixation were comparatively less myelopathic and in a better Ranawat class preoperatively, but postoperative outcome measures were well-preserved with favorable mortality rates over mean 39.6 months of follow-up. However, 11% of cases required OCF at mean 28 months post-C1-C2 fixation, largely due to instrumentation failure (80%. Conclusion: We present the largest series of surgically managed rheumatoid spines, revealing comparative data on OCF and C1-C2 fixation. Although survival has improved over the last 30 years, there have been changes in medical, surgical and perioperative management over that period of time too confounding the interpretation; however, the analysis presented suggests that rheumatoid patients presenting early in the disease process may benefit from C1 to C2 fixation, albeit with a proportion requiring OCF at a later time.

  6. Disposable surgical face masks for preventing surgical wound infection in clean surgery

    Directory of Open Access Journals (Sweden)

    Allyson Lipp

    Full Text Available BACKGROUND: Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. OBJECTIVES: To determine whether disposable surgical face masks worn by the surgical team during clean surgery prevent postoperative surgical wound infection. SEARCH METHODS: We searched The Cochrane Wounds Group Specialised Register (searched 14 September 2011; The Cochrane Central Register of Controlled Trials (CENTRAL (The Cochrane Library 2011, Issue 3; Ovid MEDLINE (2008 to August Week 5 2011; Ovid MEDLINE (In-Process &Other Non-Indexed Citations September 13, 2011; Ovid EMBASE (2008 to 2011 Week 35; and EBSCO CINAHL (2008 to 9 September 2011. SELECTION CRITERIA: Randomized controlled trials (RCTs and quasi-randomized controlled trials comparing the use of disposable surgical masks with the use of no mask. DATA COLLECTION AND ANALYSIS: Two review authors extracted data independently. MAIN RESULTS: Three trials were included, involving a total of 2113 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. AUTHORS' CONCLUSIONS: From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.

  7. STM-SQUID probe microscope

    International Nuclear Information System (INIS)

    Hayashi, Tadayuki; Tachiki, Minoru; Itozaki, Hideo

    2007-01-01

    We have developed a STM-SQUID probe microscope. A high T C SQUID probe microscope was combined with a scanning tunneling microscope for investigation of samples at room temperature in air. A high permeability probe needle was used as a magnetic flux guide to improve the spatial resolution. The probe with tip radius of less than 100 nm was prepared by microelectropolishing. The probe was also used as a scanning tunneling microscope tip. Topography of the sample surface could be measured by the scanning tunneling microscope with high spatial resolution prior to observation by SQUID microscopy. The SQUID probe microscope image could be observed while keeping the distance from the sample surface to the probe tip constant. We observed a topographic image and a magnetic image of Ni fine pattern and also a magnetically recorded hard disk. Furthermore we have investigated a sample vibration method of the static magnetic field emanating from a sample with the aim of achieving a higher signal-to-noise (S/N) ratio

  8. Characterization of coating probe with Ti-DLC for electrical scanning probe microscope

    International Nuclear Information System (INIS)

    Shia Xiaolei; Guo Liqiu; Bai Yang; Qiao Lijie

    2011-01-01

    In electrical scanning probe microscope (ESPM) applications, the wear and conductivity of the probe are undoubtedly serious concerns since they affect the integrity of the measurements. This study investigates the characterization of Ti doped diamond-like-carbon (DLC) as coating material on a silicon cantilever for ESPM. We deposited a layer of Ti-DLC thin film on the surface of Si cantilever by magnetron sputtering. The morphology and composition of the Ti-DLC films were characterized by scanning electron microscopy and Raman spectroscopy, respectively. We also compared the wear resistance, electric conductivity and scanning image quality of the Ti-DLC-coated probes with those of commercially available conductive probes. The results showed that the electric conductivity and the scanning image quality of the Ti-DLC-coated probes were the same as the commercial conductive probes, while the wear resistance and service life was significantly better.

  9. Advances in surgical treatment of chronic pancreatitis.

    Science.gov (United States)

    Ni, Qingqiang; Yun, Lin; Roy, Manish; Shang, Dong

    2015-02-08

    The incidence of chronic pancreatitis (CP) is between 2 and 200 per 100,000 persons and shows an increasing trend year by year. India has the highest incidence of CP in the world at approximately 114 to 200 per 100,000 persons. The incidence of CP in China is approximately 13 per 100,000 persons. The aim of this review is to assist surgeons in managing patients with CP in surgical treatment. We conducted a PubMed search for "chronic pancreatitis" and "surgical treatment" and reviewed relevant articles. On the basis of our review of the literature, we found that CP cannot be completely cured. The purpose of surgical therapy for CP is to relieve symptoms, especially pain; to improve the patient's quality of life; and to treat complications. Decompression (drainage), resection, neuroablation and decompression combined with resection are commonly used methods for the surgical treatment of CP. Before developing a surgical regimen, surgeons should comprehensively evaluate the patient's clinical manifestations, auxiliary examination results and medical history to develop an individualized surgical treatment regimen.

  10. Optical coherence tomography and optical coherence domain reflectometry for deep brain stimulation probe guidance

    Science.gov (United States)

    Jeon, Sung W.; Shure, Mark A.; Baker, Kenneth B.; Chahlavi, Ali; Hatoum, Nagi; Turbay, Massud; Rollins, Andrew M.; Rezai, Ali R.; Huang, David

    2005-04-01

    Deep Brain Stimulation (DBS) is FDA-approved for the treatment of Parkinson's disease and essential tremor. Currently, placement of DBS leads is guided through a combination of anatomical targeting and intraoperative microelectrode recordings. The physiological mapping process requires several hours, and each pass of the microelectrode into the brain increases the risk of hemorrhage. Optical Coherence Domain Reflectometry (OCDR) in combination with current methodologies could reduce surgical time and increase accuracy and safety by providing data on structures some distance ahead of the probe. For this preliminary study, we scanned a rat brain in vitro using polarization-insensitive Optical Coherence Tomography (OCT). For accurate measurement of intensity and attenuation, polarization effects arising from tissue birefringence are removed by polarization diversity detection. A fresh rat brain was sectioned along the coronal plane and immersed in a 5 mm cuvette with saline solution. OCT images from a 1294 nm light source showed depth profiles up to 2 mm. Light intensity and attenuation rate distinguished various tissue structures such as hippocampus, cortex, external capsule, internal capsule, and optic tract. Attenuation coefficient is determined by linear fitting of the single scattering regime in averaged A-scans where Beer"s law is applicable. Histology showed very good correlation with OCT images. From the preliminary study using OCT, we conclude that OCDR is a promising approach for guiding DBS probe placement.

  11. Mastoidectomy: anatomical parameters x surgical difficulty

    Directory of Open Access Journals (Sweden)

    Pereira Júnior, Anastácio Rodrigues

    2012-01-01

    Full Text Available Introduction: The lowered temporal meninges and/ or anterior sigmoid sinus are contiditions that can determine surgical difficulties in performing mastoidectomy. Objective: To correlate in the tomography the extent of the prolapse of the sigmoid sinus and of temporal meninges with the surgical difficulty in the mastoidectomy. Method: The tomographic measurements of prolapse sigmoid and of temporal meninges were correlated with the presence or non-presence of the surgical difficulty observed during the mastoidectomy procedure in patients with ostomatoiditis chronic (n=30. Form of study: Contemporary cohort transverse. Results: In 10 patients were observed surgical difficulty distributed as: due to prolapse of the sigmoid sinus (n = 2 or temporal meninges prolapse (n = 7 or both (n = 1. In patients in which the surgical difficulty was due to sigmoid sinus prolapse, the tomography distance of the anterior border of the sigmoid sinus to posterior wall of external auditory canal was lower than 9 mm. In patients in which surgical difficulty was due to temporal meninges prolapse, the tomographic distance to the upper plane of the petrous bone was 7 mm. Conclusion: The computerized tomography distance between the temporal meninges and the upper plane of the petrous bone 7 mm and the distance of the anterior border of the sigmoid sinus to posterior wall of external auditory canal was lower than 9 mm are predictive to the surgical difficulties to perform mastoidectomy.

  12. Radiology trainer. Surgical ambulance. Revision 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Ackermann, Ole; Barkhausen, Joerg

    2013-01-01

    The radiology trainer for surgical ambulance includes informative X-ray imaging examples for the following issues: zygoma, nasal bone, spinal cord, clavicle, shoulder, upper arms, elbow, forearms, wrist, hand, phalanx, thorax, sternum, pelvis, abdomen, hips, femur, knee, lower leg, ankle, feet.

  13. Plasma probe characteristics in low density hydrogen pulsed plasmas

    International Nuclear Information System (INIS)

    Astakhov, D I; Lee, C J; Bijkerk, F; Goedheer, W J; Ivanov, V V; Krivtsun, V M; Zotovich, A I; Zyryanov, S M; Lopaev, D V

    2015-01-01

    Probe theories are only applicable in the regime where the probe’s perturbation of the plasma can be neglected. However, it is not always possible to know, a priori, that a particular probe theory can be successfully applied, especially in low density plasmas. This is especially difficult in the case of transient, low density plasmas. Here, we applied probe diagnostics in combination with a 2D particle-in-cell model, to an experiment with a pulsed low density hydrogen plasma. The calculations took into account the full chamber geometry, including the plasma probe as an electrode in the chamber. It was found that the simulations reproduce the time evolution of the probe IV characteristics with good accuracy. The disagreement between the simulated and probe measured plasma density is attributed to the limited applicability of probe theory to measurements of low density pulsed plasmas on a similarly short time scale as investigated here. Indeed, in the case studied here, probe measurements would lead to, either a large overestimate, or underestimate of the plasma density, depending on the chosen probe theory. In contrast, the simulations of the plasma evolution and the probe characteristics do not suffer from such strict applicability limits. These studies show that probe theory cannot be justified through probe measurements. However, limiting cases of probe theories can be used to estimate upper and lower bounds on plasma densities. These theories include and neglect orbital motion, respectively, with different collisional terms leading to intermediate estimates. (paper)

  14. Surgical Site Infection among Patients Undergone Orthopaedic ...

    African Journals Online (AJOL)

    ADMIN

    with surgical site infection at Muhimbili Orthopedic Institute. ... Determination of the relationship between outcome and exposure variables ... determined by more than 2 hours length of surgical procedure (AOR= 1.4; 95%CI 1.14-6.69; ... hospital, those with metastatic fractures, back, spine were not included as they fall under.

  15. A comparative evaluation: Oral leukoplakia surgical management using diode laser, CO2 laser, and cryosurgery.

    Science.gov (United States)

    Natekar, Madhukar; Raghuveer, Hosahallli-Puttaiah; Rayapati, Dilip-Kumar; Shobha, Eshwara-Singh; Prashanth, Nagesh-Tavane; Rangan, Vinod; Panicker, Archana G

    2017-06-01

    The comparatively evaluate the three surgical treatment modalities namely cryosurgery, diode and CO2 laser surgery in terms of healing outcomes on the day of surgery, first and second week post operatively and recurrence at the end of 18 months was assessed. Thirty selected patients were divided randomly into three groups. Each group comprising of ten patients were subjected to one of the three modalities of treatment namely cryosurgery, diode laser or CO2 laser surgery for ablation of OL. Obtained data was analyzed using mainly using Chi-square and Anova tests. Study showed statistical significant differences (p > 0.05) for evaluation parameters like pain, edema and scar. The parameters like infection, recurrence, bleeding showed no statistical significance. Pain was significantly higher in CO2 laser surgery group as compared with diode laser group. There was no recurrence observed at the end of the 6 months follow up period in all the three study groups. Observations from the study highlights that all three surgical modalities used in this study were effective for treatment of OL, and the overall summation of the results of the study showed that laser therapy (CO2 and Diode) seems to offer better clinically significant results than cryotherapy. Key words: Oral premalignant lesion, leukoplakia, cryosurgery, CO2 laser surgery, diode laser surgery.

  16. Practice management education during surgical residency.

    Science.gov (United States)

    Jones, Kory; Lebron, Ricardo A; Mangram, Alicia; Dunn, Ernest

    2008-12-01

    Surgical education has undergone radical changes in the past decade. The introductions of laparoscopic surgery and endovascular techniques have required program directors to alter surgical training. The 6 competencies are now in place. One issue that still needs to be addressed is the business aspect of surgical practice. Often residents complete their training with minimal or no knowledge on coding of charges or basic aspects on how to set up a practice. We present our program, which has been in place over the past 2 years and is designed to teach the residents practice management. The program begins with a series of 10 lectures given monthly beginning in August. Topics include an introduction to types of practices available, negotiating a contract, managed care, and marketing the practice. Both medical and surgical residents attend these conferences. In addition, the surgical residents meet monthly with the business office to discuss billing and coding issues. These are didactic sessions combined with in-house chart reviews of surgical coding. The third phase of the practice management plan has the coding team along with the program director attend the outpatient clinic to review in real time the evaluation and management coding of clinic visits. Resident evaluations were completed for each of the practice management lectures. The responses were recorded on a Likert scale. The scores ranged from 4.1 to 4.8 (average, 4.3). Highest scores were given to lectures concerning negotiating employee agreements, recruiting contracts, malpractice insurance, and risk management. The medical education department has tracked resident coding compliance over the past 2 years. Surgical coding compliance increased from 36% to 88% over a 12-month period. The program director who participated in the educational process increased his accuracy from 50% to 90% over the same time period. When residents finish their surgical training they need to be ready to enter the world of business

  17. Review of emerging surgical robotic technology.

    Science.gov (United States)

    Peters, Brian S; Armijo, Priscila R; Krause, Crystal; Choudhury, Songita A; Oleynikov, Dmitry

    2018-04-01

    The use of laparoscopic and robotic procedures has increased in general surgery. Minimally invasive robotic surgery has made tremendous progress in a relatively short period of time, realizing improvements for both the patient and surgeon. This has led to an increase in the use and development of robotic devices and platforms for general surgery. The purpose of this review is to explore current and emerging surgical robotic technologies in a growing and dynamic environment of research and development. This review explores medical and surgical robotic endoscopic surgery and peripheral technologies currently available or in development. The devices discussed here are specific to general surgery, including laparoscopy, colonoscopy, esophagogastroduodenoscopy, and thoracoscopy. Benefits and limitations of each technology were identified and applicable future directions were described. A number of FDA-approved devices and platforms for robotic surgery were reviewed, including the da Vinci Surgical System, Sensei X Robotic Catheter System, FreeHand 1.2, invendoscopy E200 system, Flex® Robotic System, Senhance, ARES, the Single-Port Instrument Delivery Extended Research (SPIDER), and the NeoGuide Colonoscope. Additionally, platforms were reviewed which have not yet obtained FDA approval including MiroSurge, ViaCath System, SPORT™ Surgical System, SurgiBot, Versius Robotic System, Master and Slave Transluminal Endoscopic Robot, Verb Surgical, Miniature In Vivo Robot, and the Einstein Surgical Robot. The use and demand for robotic medical and surgical platforms is increasing and new technologies are continually being developed. New technologies are increasingly implemented to improve on the capabilities of previously established systems. Future studies are needed to further evaluate the strengths and weaknesses of each robotic surgical device and platform in the operating suite.

  18. Probing echoic memory with different voices.

    Science.gov (United States)

    Madden, D J; Bastian, J

    1977-05-01

    Considerable evidence has indicated that some acoustical properties of spoken items are preserved in an "echoic" memory for approximately 2 sec. However, some of this evidence has also shown that changing the voice speaking the stimulus items has a disruptive effect on memory which persists longer than that of other acoustical variables. The present experiment examined the effect of voice changes on response bias as well as on accuracy in a recognition memory task. The task involved judging recognition probes as being present in or absent from sets of dichotically presented digits. Recognition of probes spoken in the same voice as that of the dichotic items was more accurate than recognition of different-voice probes at each of three retention intervals of up to 4 sec. Different-voice probes increased the likelihood of "absent" responses, but only up to a 1.4-sec delay. These shifts in response bias may represent a property of echoic memory which should be investigated further.

  19. 42 CFR 482.51 - Condition of participation: Surgical services.

    Science.gov (United States)

    2010-10-01

    ... of medicine or osteopathy. (2) Licensed practical nurses (LPNs) and surgical technologists (operating... performing surgery in accordance with the competencies of each practitioner. The surgical service must...

  20. Proximal Probes Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Proximal Probes Facility consists of laboratories for microscopy, spectroscopy, and probing of nanostructured materials and their functional properties. At the...

  1. FLOW CYTOMETRIC APPLICABILITY OF FLUORESCENT VITALITY PROBES ON PHYTOPLANKTON1.

    Science.gov (United States)

    Peperzak, Louis; Brussaard, Corina P D

    2011-06-01

    The applicability of six fluorescent probes (four esterase probes: acetoxymethyl ester of Calcein [Calcein-AM], 5-chloromethylfluorescein diacetate [CMFDA], fluorescein diacetate [FDA], and 2',7'-dichlorofluorescein diacetate [H 2 DCFDA]; and two membrane probes: bis-(1,3-dibutylbarbituric acid) trimethine oxonol [DiBAC 4 (3)] and SYTOX-Green) as vitality stains was tested on live and killed cells of 40 phytoplankton strains in exponential and stationary growth phases, belonging to 12 classes and consisting of four cold-water, 26 temperate, and four warm-water species. The combined live/dead ratios of all six probes indicated significant differences between the 12 plankton classes (P live/dead ratios of FDA and CMFDA were not significantly different from each other, and both performed better than Calcein-AM and H 2 DCFDA (P live/dead ratios) among all six probes belonged to nine genera from six classes of phytoplankton. In conclusion, FDA, CMFDA, DIBAC 4 (3), and SYTOX-Green represent a wide choice of vitality probes in the study of phytoplankton ecology, applicable in many species from different algal classes, originating from different regions and at different stages of growth. © 2011 Phycological Society of America.

  2. Factors influencing incident reporting in surgical care.

    Science.gov (United States)

    Kreckler, S; Catchpole, K; McCulloch, P; Handa, A

    2009-04-01

    To evaluate the process of incident reporting in a surgical setting. In particular: the influence of event outcome on reporting behaviour; staff perception of surgical complications as reportable events. Anonymous web-based questionnaire survey. General Surgical Department in a UK teaching hospital. Of 203 eligible staff, 55 (76.4%) doctors and 82 (62.6%) nurses participated. Knowledge and use of local reporting system; propensity to report incidents which vary by outcome (harm, no harm, harm prevented); propensity to report surgical complications; practical and psychological barriers to reporting. Nurses were significantly more likely to know of the local reporting system and to have recently completed a report than doctors. The level of harm (F(1.8,246) = 254.2, pvs 53%, z = 4.633, psystems.

  3. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  4. Luminescence recognition of different organophosphorus pesticides by the luminescent Eu(III)-pyridine-2,6-dicarboxylic acid probe

    Energy Technology Data Exchange (ETDEWEB)

    Azab, Hassan A., E-mail: azab2@yahoo.com [Chemistry Department, Faculty of Science, Suez Canal University, Ismailia 41522 (Egypt); Duerkop, Axel [Institute of Analytical Chemistry, Chemo and Biosensors, Regensburg University, D-93040 Regensburg (Germany); Anwar, Z.M.; Hussein, Belal H.M.; Rizk, Moustafa A.; Amin, Tarek [Chemistry Department, Faculty of Science, Suez Canal University, Ismailia 41522 (Egypt)

    2013-01-08

    Highlights: Black-Right-Pointing-Pointer Europium (III) luminescence quenching has been used for sensing organophosphorous pesticides. Black-Right-Pointing-Pointer Four guest pesticides chlorfenvinphos, malathion, azinphos, and paraxon ethyl were used. Black-Right-Pointing-Pointer A sensitive rapid, cheap direct method for the determination of the pesticides has been developed. Black-Right-Pointing-Pointer The method was applied to the determination of the OPs in tap, river, mineral, and waste waters. - Abstract: Luminescence quenching of a novel long lived Eu(III)-pyridine-2,6-dicarboxylic acid probe of 1:2 stoichiometric ratio has been studied in 0.10 volume fraction ethanol-water mixture at pH 7.5 (HEPES buffer) in the presence of the organophosphorus pesticides chlorfenvinphos (P1), malathion (P2), azinphos (P3), and paraxon ethyl (P4). The luminescence intensity of Eu(III)-(PDCA){sub 2} probe decreases as the concentration of the pesticide increases. It was observed that the quenching due to P3 and P4 proceeds via both diffusional and static quenching processes. Direct methods for the determination of the pesticides under investigation have been developed using the luminescence quenching of Eu(III)-pyridine-2,6-dicarboxylic acid probe in solution. The linear range for determination of the selected pesticides is 1.0-35.0 {mu}M. The detection limits were 0.24-0.55 {mu}M for P3, P4, and P1 and 2.5 {mu}M for P2, respectively. The binding constants (K), and thermodynamic parameters of the OPs with Eu(III)-(PDCA){sub 2} were evaluated. Positive and negative values of entropy ({Delta}S) and enthalpy ({Delta}H) changes for Eu(III)-(PDCA){sub 2}-P1 ternary complex were calculated. As the waters in this study do not contain the above mentioned OPs over the limit detectable by the method, a recovery study was carried out after the addition of the adequate amounts of the organophosphorus pesticides under investigation.

  5. Surgical Management of Malignant Tumors of the Trachea: Report of Two Cases and Review of Literature

    Directory of Open Access Journals (Sweden)

    Ryuji Yasumatsu

    2012-06-01

    Full Text Available Malignant neoplasms occurring from the trachea are extremely rare. Therefore, their clinical characteristics and surgical results have not been thoroughly discussed. These tumors are often misdiagnosed and treated as bronchial asthma or chronic obstructive pulmonary disease. It is critically important to probe the cause-effect relationship between the medical presentations and the clinical diagnosis. In this report, two cases of tracheal malignancy suffering from dyspnea due to obstruction of the proximal trachea are described, and a review of the literature is presented.

  6. Surgical management of gynecomastia: experience of a general surgery center.

    Science.gov (United States)

    Longheu, A; Medas, F; Corrias, F; Farris, S; Tatti, A; Pisano, G; Erdas, E; Calò, P G

    2016-01-01

    Gynecomastia is a common finding in male population of all ages. The aim of our study was to present our experience and goals in surgical treatment of gynecomastia. Clinical records of patients affected by gynecomastia referred to our Department of Surgery between September 2008 and January 2015 were analyzed. 50 patients were included in this study. Gynecomastia was monolateral in 12 patients (24%) and bilateral in 38 (76%); idiopathic in 41 patients (82%) and secondary in 9 (18%). 39 patients (78%) underwent surgical operation under general anaesthesia, 11 (22%) under local anaesthesia. 3 patients (6%) presented recurrent disease. Webster technique was performed in 28 patients (56%), Davidson technique in 16 patients (32%); in 2 patients (4%) Pitanguy technique was performed and in 4 patients (8%) a mixed surgical technique was performed. Mean surgical time was 80.72±35.14 minutes, median postoperative stay was 1.46±0.88 days. 2 patients (4%) operated using Davidson technique developed a hematoma, 1 patient (2%) operated with the same technique developed hypertrophic scar. Several surgical techniques are described for surgical correction of gynecomastia. If performed by skilled general surgeons surgical treatment of gynecomastia is safe and permits to reach satisfactory aesthetic results.

  7. Positron emission tomography probe to monitor selected sugar metabolism in vivo

    Science.gov (United States)

    Witte, Owen; Clark, Peter M.; Castillo, Blanca Graciela Flores; Jung, Michael E.; Evdokimov, Nikolai M.

    2017-03-14

    The invention disclosed herein discloses selected ribose isomers that are useful as PET probes (e.g. [18F]-2-fluoro-2-deoxy-arabinose). These PET probes are useful, for example, in methods designed to monitor physiological processes including ribose metabolism and/or to selectively observe certain tissue/organs in vivo. The invention disclosed herein further provides methods for making and using such probes.

  8. Surgical Management of Localized Scleroderma.

    Science.gov (United States)

    Lee, Jae Hyun; Lim, Soo Yeon; Lee, Jang Hyun; Ahn, Hee Chang

    2017-09-01

    Localized scleroderma is characterized by a thickening of the skin from excessive collagen deposits. It is not a fatal disease, but quality of life can be adversely affected due to changes in skin appearance, joint contractures, and, rarely, serious deformities of the face and extremities. We present six cases of localized scleroderma in face from our surgical practice. We reviewed six localized scleroderma cases that were initially treated with medication and then received follow-up surgery between April 2003 and February 2015. Six patients had facial lesions. These cases presented with linear dermal sclerosis on the forehead, oval subcutaneous and dermal depression in the cheek. En coup de sabre (n=4), and oval-shaped lesion of the face (n=2) were successfully treated. Surgical methods included resection with or without Z-plasty (n=3), fat graft (n=1), dermofat graft (n=1), and adipofascial free flap (n=1). Deformities of the affected parts were surgically corrected without reoccurrence. We retrospectively reviewed six cases of localized scleroderma that were successfully treated with surgery. And we propose an algorithm for selecting the best surgical approach for individual localized scleroderma cases. Although our cases were limited in number and long-term follow-up will be necessary, we suggest that surgical management should be considered as an option for treating scleroderma patients.

  9. Surgical treatment of chronic pancreatitis in young patients.

    Science.gov (United States)

    Zhou, Feng; Gou, Shan-Miao; Xiong, Jiong-Xin; Wu, He-Shui; Wang, Chun-You; Liu, Tao

    2014-10-01

    The main treatment strategies for chronic pancreatitis in young patients include therapeutic endoscopic retrograde cholangio-pancreatography (ERCP) intervention and surgical intervention. Therapeutic ERCP intervention is performed much more extensively for its minimally invasive nature, but a part of patients are referred to surgery at last. Historical and follow-up data of 21 young patients with chronic pancreatitis undergoing duodenum-preserving total pancreatic head resection were analyzed to evaluate the outcomes of therapeutic ERCP intervention and surgical intervention in this study. The surgical complications of repeated therapeutic ERCP intervention and surgical intervention were 38% and 19% respectively. During the first therapeutic ERCP intervention to surgical intervention, 2 patients developed diabetes, 5 patients developed steatorrhea, and 5 patients developed pancreatic type B pain. During the follow-up of surgical intervention, 1 new case of diabetes occurred, 1 case of steatorrhea recovered, and 4 cases of pancreatic type B pain were completely relieved. In a part of young patients with chronic pancreatitis, surgical intervention was more effective than therapeutic ERCP intervention on delaying the progression of the disease and relieving the symptoms.

  10. NASA's interstellar probe mission

    International Nuclear Information System (INIS)

    Liewer, P.C.; Ayon, J.A.; Wallace, R.A.; Mewaldt, R.A.

    2000-01-01

    NASA's Interstellar Probe will be the first spacecraft designed to explore the nearby interstellar medium and its interaction with our solar system. As envisioned by NASA's Interstellar Probe Science and Technology Definition Team, the spacecraft will be propelled by a solar sail to reach >200 AU in 15 years. Interstellar Probe will investigate how the Sun interacts with its environment and will directly measure the properties and composition of the dust, neutrals and plasma of the local interstellar material which surrounds the solar system. In the mission concept developed in the spring of 1999, a 400-m diameter solar sail accelerates the spacecraft to ∼15 AU/year, roughly 5 times the speed of Voyager 1 and 2. The sail is used to first bring the spacecraft to ∼0.25 AU to increase the radiation pressure before heading out in the interstellar upwind direction. After jettisoning the sail at ∼5 AU, the spacecraft coasts to 200-400 AU, exploring the Kuiper Belt, the boundaries of the heliosphere, and the nearby interstellar medium

  11. Contribution to determination of coal grindability using Hardgrove method

    OpenAIRE

    Tichánek, František

    2008-01-01

    The paper deals with determination of grindability of coal using Hardgrove method. Some non-availabilities of determination are mentioned as well as factors affecting grindability and relations for conversion of Hardgrove Grindability Index (HGI) values to Bond Work Index (Wi). Paper also provides information on utilization of Hardgrove method in Czech Republic and indicates HGI values for coal from OKD-Karvina region. Příspěvek se zabývá stanovením melitelnosti uhlí pomocí metody Hardgrov...

  12. Improved patient selection by stratified surgical intervention

    DEFF Research Database (Denmark)

    Wang, Miao; Bünger, Cody E; Li, Haisheng

    2015-01-01

    BACKGROUND CONTEXT: Choosing the best surgical treatment for patients with spinal metastases remains a significant challenge for spine surgeons. There is currently no gold standard for surgical treatments. The Aarhus Spinal Metastases Algorithm (ASMA) was established to help surgeons choose...... the most appropriate surgical intervention for patients with spinal metastases. PURPOSE: The purpose of this study was to evaluate the clinical outcome of stratified surgical interventions based on the ASMA, which combines life expectancy and the anatomical classification of patients with spinal metastases...... survival times in the five surgical groups determined by the ASMA were 2.1 (TS 0-4, TC 1-7), 5.1 (TS 5-8, TC 1-7), 12.1 (TS 9-11, TC 1-7 or TS 12-15, TC 7), 26.0 (TS 12-15, TC 4-6), and 36.0 (TS 12-15, TC 1-3) months. The 30-day mortality rate was 7.5%. Postoperative neurological function was maintained...

  13. Development of conductivity probe and temperature probe for in-situ measurements in hydrological studies

    International Nuclear Information System (INIS)

    Chandra, U.; Galindo, B.J.; Castagnet, A.C.G.

    1981-05-01

    A conductivity probe and a temperature probe have been developed for in-situ measurements in various hydrological field studies. The conductivity probe has platinum electrodes and is powered with two 12 volt batteries. The sensing element of the temperature probe consists of a resistor of high coefficient of temperature. Response of the conductivity probe is measured in a milliampere mater while the resistance of the thermistor is read by a digital meter. The values of conductivity and temperature are derived from respective calibration. The probes are prototype and their range of measurement can be improved depending upon the requirement of the field problem. (Author) [pt

  14. Electron probe micro-analysis of irradiated Triso-coated UO2 particles, (1)

    International Nuclear Information System (INIS)

    Ogawa, Toru; Minato, Kazuo; Fukuda, Kosaku; Ikawa, Katsuichi

    1983-11-01

    The Triso-coated low-enriched UO 2 particles were subjected to the post-irradiation electron probe micro-analysis. Observations and analyses on the amoeba effect, inclusions and solutes in the UO 2 matrix were made. In the cooler side of the particle which suffered extensive kernel migration, two significant features were observed: (1) the wake of minute particles, presumably UO 2 , left by the moving kernel in the carbon phase and (2) carbon precipitation in the pores and along the grain boundaries of the UO 2 kernel. Both features could be hardly explained by the gas-phase mechanism of carbon transport and rather suggest the solid state mechanism. Two-types of 4d-transition metal inclusions were observed: the one which was predominantly Mo with a fraction of Tc and another which was enriched with Ru and containing significant amount of Si. The Mo and Si were also found in the UO 2 matrix; the observation led to the discussion of the oxygen potential in the irradiated Triso-coated UO 2 particle. (author)

  15. Laser-heated emissive plasma probe.

    Science.gov (United States)

    Schrittwieser, Roman; Ionita, Codrina; Balan, Petru; Gstrein, Ramona; Grulke, Olaf; Windisch, Thomas; Brandt, Christian; Klinger, Thomas; Madani, Ramin; Amarandei, George; Sarma, Arun K

    2008-08-01

    Emissive probes are standard tools in laboratory plasmas for the direct determination of the plasma potential. Usually they consist of a loop of refractory wire heated by an electric current until sufficient electron emission. Recently emissive probes were used also for measuring the radial fluctuation-induced particle flux and other essential parameters of edge turbulence in magnetized toroidal hot plasmas [R. Schrittwieser et al., Plasma Phys. Controlled Fusion 50, 055004 (2008)]. We have developed and investigated various types of emissive probes, which were heated by a focused infrared laser beam. Such a probe has several advantages: higher probe temperature without evaporation or melting and thus higher emissivity and longer lifetime, no deformation of the probe in a magnetic field, no potential drop along the probe wire, and faster time response. The probes are heated by an infrared diode laser with 808 nm wavelength and an output power up to 50 W. One probe was mounted together with the lens system on a radially movable probe shaft, and radial profiles of the plasma potential and of its oscillations were measured in a linear helicon discharge.

  16. Laser-heated emissive plasma probe

    International Nuclear Information System (INIS)

    Schrittwieser, Roman; Ionita, Codrina; Balan, Petru; Gstrein, Ramona; Grulke, Olaf; Windisch, Thomas; Brandt, Christian; Klinger, Thomas; Madani, Ramin; Amarandei, George; Sarma, Arun K.

    2008-01-01

    Emissive probes are standard tools in laboratory plasmas for the direct determination of the plasma potential. Usually they consist of a loop of refractory wire heated by an electric current until sufficient electron emission. Recently emissive probes were used also for measuring the radial fluctuation-induced particle flux and other essential parameters of edge turbulence in magnetized toroidal hot plasmas [R. Schrittwieser et al., Plasma Phys. Controlled Fusion 50, 055004 (2008)]. We have developed and investigated various types of emissive probes, which were heated by a focused infrared laser beam. Such a probe has several advantages: higher probe temperature without evaporation or melting and thus higher emissivity and longer lifetime, no deformation of the probe in a magnetic field, no potential drop along the probe wire, and faster time response. The probes are heated by an infrared diode laser with 808 nm wavelength and an output power up to 50 W. One probe was mounted together with the lens system on a radially movable probe shaft, and radial profiles of the plasma potential and of its oscillations were measured in a linear helicon discharge

  17. Laser-heated emissive plasma probe

    Science.gov (United States)

    Schrittwieser, Roman; Ionita, Codrina; Balan, Petru; Gstrein, Ramona; Grulke, Olaf; Windisch, Thomas; Brandt, Christian; Klinger, Thomas; Madani, Ramin; Amarandei, George; Sarma, Arun K.

    2008-08-01

    Emissive probes are standard tools in laboratory plasmas for the direct determination of the plasma potential. Usually they consist of a loop of refractory wire heated by an electric current until sufficient electron emission. Recently emissive probes were used also for measuring the radial fluctuation-induced particle flux and other essential parameters of edge turbulence in magnetized toroidal hot plasmas [R. Schrittwieser et al., Plasma Phys. Controlled Fusion 50, 055004 (2008)]. We have developed and investigated various types of emissive probes, which were heated by a focused infrared laser beam. Such a probe has several advantages: higher probe temperature without evaporation or melting and thus higher emissivity and longer lifetime, no deformation of the probe in a magnetic field, no potential drop along the probe wire, and faster time response. The probes are heated by an infrared diode laser with 808nm wavelength and an output power up to 50W. One probe was mounted together with the lens system on a radially movable probe shaft, and radial profiles of the plasma potential and of its oscillations were measured in a linear helicon discharge.

  18. Radiodiagnosis of lung syndrome in surgical sepsis

    International Nuclear Information System (INIS)

    Dvojnykh, V.P.; Palagin, E.K.

    1991-01-01

    The results of treatment of 23 patients with acute surgical sepsis were analysed. It was shown that the X-ray examination must be obligatory in surveillance of patients with purulent foci. Two roentgenological variants are possible in surgical sepsis: central and perepheric. X-ray examinations of chest organs should be conducted every 2-3 day

  19. The pregnant female surgical resident

    Directory of Open Access Journals (Sweden)

    Shifflette V

    2018-05-01

    Full Text Available Vanessa Shifflette,1 Susannah Hambright,2 Joseph Darryl Amos,1 Ernest Dunn,3 Maria Allo4 1Associates in Surgical Acute Care, Methodist Dallas Medical Center, Dallas, TX, USA; 2Methodist Surgical Associates, Methodist Dallas Medical Center, Dallas, TX, USA; 3Graduate Medical Education - General Surgery, Methodist Dallas Medical Center, Dallas, TX, USA; 4Santa Clara Valley Medical Center, San Jose, CA, USA Background: Surgery continues to be an intense, time-consuming residency. Many medical students decide against surgery as a profession due to the long work hours and family strain. The pregnant female surgical resident has an added stress factor compared to her male counterpart. Methods: We distributed an electronic, online 26-question survey to 32 general surgery programs in the southwestern region of the United States. Each program distributed our survey to the female surgical residents who had been pregnant during residency in the last 5 years. Each program was re-contacted 6 weeks after the initial contact. Most questions were in a 5-point Likert scale format. The responses were collected and analyzed using the Survey Monkey website. Results: An unvalidated survey was sent to 32 general surgery programs and 26 programs responded (81%. Each program was asked for the total number of possible responses from female residents that met our criteria (60 female residents. Seven of the programs (27% stated that they have had zero residents pregnant. We had 22 residents respond (37%. Over half of the residents (55% were pregnant during their 2nd or 3rd year of residency, with only 18% pregnant during a research year. Thirty-one percent had a lower American Board of Surgery In-Training Exam (ABSITE score. Ninety percent of the residents were able to take 4 weeks or more for maternity leave. Most of the residents (95% stated that they would do this again during residency given the opportunity, but many of the residents felt that returning back to work

  20. A Phase 2 Trial of Stereotactic Radiosurgery Boost After Surgical Resection for Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, Cameron [Human Oncology and Pathogenesis Program, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurosurgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Yang, T. Jonathan [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Hilden, Patrick; Zhang, Zhigang [Department of Epidemiology and Biostatistics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Chan, Kelvin; Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Chan, Timothy A. [Human Oncology and Pathogenesis Program, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Lymberis, Stella C. [Department of Radiation Oncology, New York University Langone Medical Center, New York, New York (United States); Narayana, Ashwatha [Department of Radiation Oncology, Greenwich Hospital, Greenwich, Connecticut (United States); Tabar, Viviane; Gutin, Philip H. [Department of Neurosurgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Ballangrud, Åse [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Beal, Kathryn, E-mail: BealK@MSKCC.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2014-01-01

    Purpose: To evaluate local control after surgical resection and postoperative stereotactic radiosurgery (SRS) for brain metastases. Methods and Materials: A total of 49 patients (50 lesions) were enrolled and available for analysis. Eligibility criteria included histologically confirmed malignancy with 1 or 2 intraparenchymal brain metastases, age ≥18 years, and Karnofsky performance status (KPS) ≥70. A Cox proportional hazard regression model was used to test for significant associations between clinical factors and overall survival (OS). Competing risks regression models, as well as cumulative incidence functions, were fit using the method of Fine and Gray to assess the association between clinical factors and both local failure (LF; recurrence within surgical cavity or SRS target), and regional failure (RF; intracranial metastasis outside of treated volume). Results: The median follow-up was 12.0 months (range, 1.0-94.1 months). After surgical resection, 39 patients with 40 lesions were treated a median of 31 days (range, 7-56 days) later with SRS to the surgical bed to a median dose of 1800 cGy (range, 1500-2200 cGy). Of the 50 lesions, 15 (30%) demonstrated LF after surgery. The cumulative LF and RF rates were 22% and 44% at 12 months. Patients who went on to receive SRS had a significantly lower incidence of LF (P=.008). Other factors associated with improved local control include non-small cell lung cancer histology (P=.048), tumor diameter <3 cm (P=.010), and deep parenchymal tumors (P=.036). Large tumors (≥3 cm) with superficial dural/pial involvement showed the highest risk for LF (53.3% at 12 months). Large superficial lesions treated with SRS had a 54.5% LF. Infratentorial lesions were associated with a higher risk of developing RF compared to supratentorial lesions (P<.001). Conclusions: Postoperative SRS is associated with high rates of local control, especially for deep brain metastases <3 cm. Tumors ≥3 cm with superficial dural

  1. Innovative SPM Probes for Energy-Storage Science: MWCNT-Nanopipettes to Nanobattery Probes

    Science.gov (United States)

    Larson, Jonathan; Talin, Alec; Pearse, Alexander; Kozen, Alexander; Reutt-Robey, Janice

    As energy-storage materials and designs continue to advance, new tools are needed to direct and explore ion insertion/de-insertion at well-defined battery materials interfaces. Scanned probe tips, assembled from actual energy-storage materials, permit SPM measures of local cathode-anode (tip-sample) interactions, including ion transfer. We present examples of ``cathode'' MWCNT-terminated STM probe tips interacting with Li(s)/Si(111) anode substrates. The MWCNT tip functions as both SPM probe and Li-nanopipette,[1] for controlled transport and manipulation of Li. Local field conditions for lithium ionization and transfer are determined and compared to electrostatic models. Additional lithium metallic and oxide tips have been prepared by thin film deposition on conventional W tips, the latter of which effectively functions as a nanobattery. We demonstrate use of these novel probe materials in the local lithiation of low-index Si anode interfaces, probing local barriers for lithium insertion. Prospects and limitations of these novel SPM probes will be discussed. U.S. Department of Energy Award Number DESC0001160.

  2. Undergraduate basic surgical skills education: impact on attitudes to a career in surgery and surgical skills acquisition.

    Science.gov (United States)

    McAnena, P F; O'Halloran, N; Moloney, B M; Courtney, D; Waldron, R M; Flaherty, G; Kerin, M J

    2018-05-01

    Basic surgical skills modules in medical education are effective in teaching skills and increasing confidence among students approaching surgery. However, these modules are not delivered universally and their effect on the professional development of graduates has not been established. We aimed to assess the impact of a 10-week basic surgical skills module on attitudes and technical skills of first year medical students compared to interns. Eighteen students participated and were assessed using a 4-part questionnaire. Technical skills were assessed by observing students perform a basic interrupted suture, using the objective structured assessment of technical skills (OSATS) tool. Fourteen interns were recruited. Students were more confident in surgical scrubbing (mean score 4.0 vs. 2.86, p = 0.001), and performing a basic suture (4.05 vs. 1.93, p = 0.000), more enthusiastic about assisting with an operation (4.5 vs. 3.0, p = 0.001) and more likely to consider a career in surgery (4.16 vs. 2.28, p = 0.000). Technical skills were greater in the student group (mean score 30.8 vs. 19.6, p = 0.001). Five interns had taken part in surgical skills modules as undergraduates. Their technical skills were significantly higher compared to interns who had not (n = 9) (28.8 vs. 14.5, p = 0.006), and they were more likely to consider a career in surgery (3.6 vs. 1.5, p = 0.036). The introduction of surgical skills teaching to the undergraduate medical curriculum has a positive impact on students' attitudes towards surgery and accelerates basic technical skills development. Consideration should be given to development of a standardised undergraduate core curriculum in basic surgical skills teaching.

  3. Minimizing surgical skin incision scars with a latex surgical glove.

    Science.gov (United States)

    Han, So-Eun; Ryoo, Suk-Tae; Lim, So Young; Pyon, Jai-Kyung; Bang, Sa-Ik; Oh, Kap-Sung; Mun, Goo-Hyun

    2013-04-01

    The current trend in minimally invasive surgery is to make a small surgical incision. However, the excessive tensile stress applied by the retractors to the skin surrounding the incision often results in a long wound healing time and extensive scarring. To minimize these types of wound problems, the authors evaluated a simple and cost-effective method to minimize surgical incision scars based on the use of a latex surgical glove. The tunnel-shaped part of a powder-free latex surgical glove was applied to the incision and the dissection plane. It was fixed to the full layer of the dissection plane with sutures. The glove on the skin surface then was sealed with Ioban (3 M Health Care, St. Paul, MN, USA) to prevent movement. The operation proceeded as usual, with the retractor running through the tunnel of the latex glove. It was possible to complete the operation without any disturbance of the visual field by the surgical glove, and the glove was neither torn nor separated by the retractors. The retractors caused traction and friction during the operation, but the extent of damage to the postoperative skin incision margin was remarkably less than when the operation was performed without a glove. This simple and cost-effective method is based on the use of a latex surgical glove to protect the surgical skin incision site and improve the appearance of the postoperative scar. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. Six Degree-of-Freedom Haptic Simulation of Probing Dental Caries Within a Narrow Oral Cavity.

    Science.gov (United States)

    Wang, Dangxiao; Zhao, Xiaohan; Shi, Youjiao; Zhang, Yuru; Hou, Jianxia; Xiao, Jing

    2016-01-01

    Haptic simulation of handling pathological tissues is a crucial component to enhance virtual surgical training systems. In this paper, we introduce a configuration-based optimization approach to simulate the exploration and diagnosis of carious tissues in dental operations. To simulate the six Degree-of-Freedom (6DoF) haptic interaction between the dental probe and the oral tissues, we introduce two interaction states, the sliding state and the penetration state, which simulate the exploration on the surface of and inside of the caries, respectively. Penetration criteria considering a contact force threshold are defined to trigger the switch between the two states. By utilizing a simplified friction model based on the optimization approach, various multi-region frictional contacts between the probe and carious tissues are simulated. To simulate the exploration within the carious tissues for diagnosing the depth of the caries, a dynamic sphere tree is used to constrain the insertion/extraction of the probe within carious tissues along a fixed direction while enabling simulation of additional contacts of the probe with neighboring oral tissues during the insertion/extraction process. Experimental results show that decays with different levels of stiffness and friction coefficients can be stably simulated. Preliminary user studies show that users could easily identify the invisible boundary between the decay and healthy tissues and correctly rank the depth of target decays within a required time limit. The proposed approach could be used for training delicate motor skill of probing target carious teeth in a narrow oral cavity, which requires collaborated control of tool posture and insertion/extraction force, while avoiding damages to adjacent healthy tissues of the tongue and gingiva.

  5. Surgical Site Infection Following Fixation of Acetabular Fractures.

    Science.gov (United States)

    Iqbal, Faizan; Younus, Sajid; Asmatullah; Zia, Osama Bin; Khan, Naveed

    2017-09-01

    Acetabular fractures are mainly caused by high energy trauma. Surgical fixation of these fractures requires extensive surgical exposure which increases the length of operation and blood loss as well. This may increase the risk of surgical site infection. Our aim is to evaluate the prevalence of surgical site infections and the risk factors associated with it so as to minimize its chances. A total of 261 patients who underwent acetabular fracture surgery were retrospectively reviewed. Patients were divided into 2 groups, with or without surgical site infection. Factors examined include patients' gender, age, body mass index (BMI), time between injury and surgery, operative time, estimated blood loss, number of packed red blood cell transfused, length of total intensive care unit (ICU) stay, fracture type, surgical approach, smoking status, patients' comorbids and associated injuries. Fourteen patients (5.4%) developed surgical site infection. Out of 14 infections, 4 were superficial and 10 were deep. The factors that were found to be associated with surgical site infection following acetabular fracture fixation were prolonged operation time, increased BMI, prolonged ICU stay, larger amount of packed red blood cell transfused and associated genitourinary and abdominal trauma. In our study, we conclude that measures should be undertaken to attenuate the chances of surgical site infection in this major surgery by considering the risk factors significantly associated with it.

  6. Theory of NMR probe design

    International Nuclear Information System (INIS)

    Schnall, M.D.

    1988-01-01

    The NMR probe is the intrinsic part of the NMR system which allows transmission of a stimulus to a sample and the reception of a resulting signal from a sample. NMR probes are used in both imaging and spectroscopy. Optimal probe design is important to the production of adequate signal/moise. It is important for anyone using NMR techniques to understand how NMR probes work and how to optimize probe design

  7. Surgical treatment of cavernous malformations involving medulla oblongata.

    Science.gov (United States)

    Zhang, Si; Lin, Sen; Hui, Xuhui; Li, Hao; You, Chao

    2017-03-01

    Surgical treatment of cavernous malformations (CMs) involving medulla oblongata is more difficult than the CMs in other sites because of the surrounding vital structures. However, the distinctive features and treatment strategies have not been well illustrated. Therefore, we enrolled a total of 19 patients underwent surgical treatment of CMs involving medulla oblongata in our hospital from August 2008 to August 2014. The clinical features, surgical management and clinical outcome of these patients were retrospectively analyzed, while our institutional surgical indications, approaches and microsurgical techniques were discussed. In our study, gross total resection was achieved in 17 patients and subtotal resection in 2. Two patients underwent emergency surgeries due to severe and progressive neurological deficits. The postoperative new-onset or worsened neurological deficits occurred in 6 patients. After a mean follow-up of 45.8±22.2months, the neurological status was improved in 10 patients and remained stable in 7. The mean modified Rankin Scale (mRS) was 2.58±1.26 preoperatively, 3.11±0.99 postoperatively and 1.84±1.42 at the recent follow-up, respectively. During the follow-up period, no rehemorrhage and recurrence occurred, and the residual lesions remained stable. We recommended surgical resection of symptomatic CMs involving medulla oblongata via optimal approaches, feasible entry zones and meticulous microsurgical techniques in attempting to achieve safe resection and favorable outcome. The clinical features, surgical indications, timing and microsurgical techniques of this special entity should be distinctive from the brainstem cavernous malformations in other sites. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Utility of 3D Reconstruction of 2D Liver Computed Tomography/Magnetic Resonance Images as a Surgical Planning Tool for Residents in Liver Resection Surgery.

    Science.gov (United States)

    Yeo, Caitlin T; MacDonald, Andrew; Ungi, Tamas; Lasso, Andras; Jalink, Diederick; Zevin, Boris; Fichtinger, Gabor; Nanji, Sulaiman

    A fundamental aspect of surgical planning in liver resections is the identification of key vessel tributaries to preserve healthy liver tissue while fully resecting the tumor(s). Current surgical planning relies primarily on the surgeon's ability to mentally reconstruct 2D computed tomography/magnetic resonance (CT/MR) images into 3D and plan resection margins. This creates significant cognitive load, especially for trainees, as it relies on image interpretation, anatomical and surgical knowledge, experience, and spatial sense. The purpose of this study is to determine if 3D reconstruction of preoperative CT/MR images will assist resident-level trainees in making appropriate operative plans for liver resection surgery. Ten preoperative patient CT/MR images were selected. Images were case-matched, 5 to 2D planning and 5 to 3D planning. Images from the 3D group were segmented to create interactive digital models that the resident can manipulate to view the tumor(s) in relation to landmark hepatic structures. Residents were asked to evaluate the images and devise a surgical resection plan for each image. The resident alternated between 2D and 3D planning, in a randomly generated order. The primary outcome was the accuracy of resident's plan compared to expert opinion. Time to devise each surgical plan was the secondary outcome. Residents completed a prestudy and poststudy questionnaire regarding their experience with liver surgery and the 3D planning software. Senior level surgical residents from the Queen's University General Surgery residency program were recruited to participate. A total of 14 residents participated in the study. The median correct response rate was 2 of 5 (40%; range: 0-4) for the 2D group, and 3 of 5 (60%; range: 1-5) for the 3D group (p surgery planning increases accuracy of resident surgical planning and decreases amount of time required. 3D reconstruction would be a useful model for improving trainee understanding of liver anatomy and surgical

  9. Feasibility study of a photoconductor based dosimeter for quality assurance in radiotherapy

    Science.gov (United States)

    Lee, Y. K.; Kim, S. W.; Kim, J. N.; Kang, Y. N.; Kim, J. Y.; Lee, D. S.; Kim, K. T.; Han, M. J.; Ahn, K. J.; Park, S. K.

    2017-09-01

    With the recent market entries of new types of linear accelerators (LINACs) with a multi leaf collimator (MLC) mounted on them, high-precision radiosurgery applying a LINAC to measure high-dose radiation on the target region has been gaining popularity. Systematic and accurate quality assurance (QA) is of vital important for high-precision radiosurgery because of its increased risk of side effects including life-threatening ones such as overexposure of healthy tissues to high-dose radiation beams concentrated on small areas. Therefore, accurate dose and dose-distribution measurements are crucial in the treatment procedure. The accurate measurement of the properties of beams concentrated on small areas requires high-precision dosimeters capable of high-resolution output and dose mapping as well as accurate dosimetry in penumbra regions. In general, the properties of beams concentrated on small areas are measured using thermos luminescent dosimeters (TLD), diode detectors, ion chambers, diamond detectors, or films, and many papers have presented the advantages and disadvantages of each of these detectors for dosimetry. In this study, a solid-state photoconductor dosimeter was developed, and its clinical usability was tested by comparing its relative dosimetric performance with that of a conventional ion chamber. As materials best-suited for radiation dosimeters, four candidates namely lead (II) iodide (PbI2), lead (II) oxide (PbO), mercury (II) iodide (HgI2), and HgI2/ titanium dioxide (TiO2) composite, the performances of which were proved in previous studies, were used. The electrical properties of each candidate material were examined using the sedimentation method, one of the particle-in-binder (PIB) methods, and unit-cell-type prototypes were fabricated. The unit-cell samples thus prepared were cut into specimens of area 1 × 1 cm2 with 400-μ m thickness. The electrical properties of each sample, such as sensitivity, dark current, output current, rising time

  10. Probing the random distribution of half-metallic Co2Mn1-xFexSi Heusler alloys

    NARCIS (Netherlands)

    Wurmehl, S.; Kohlhepp, J.T.; Swagten, H.J.M.; Koopmans, B.; Wójcik, M.; Balke, B.; Blum, C.G.F.; Ksenofontov, V.; Fecher, G.H.; Felser, C.

    2007-01-01

    Co2Mn1-xFexSi Heusler alloys crystallize in the L21 structure. This structure type requires random distribution of Mn and Fe in case of the mixed alloys. The spin echo nuclear magnetic resonance (NMR) technique probes the direct local environments of the active atoms and is thus able to resolve next

  11. S L Sharma

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. S L Sharma. Articles written in Bulletin of Materials Science. Volume 25 Issue 2 April 2002 pp 85-93 Materials Synthesis. Photoelectronic properties of HgI2 crystals for nuclear radiation detection · S L Sharma H N Acharya · More Details Abstract Fulltext PDF. Photoelectronic ...

  12. Surgical care in the isolated military hospital.

    Science.gov (United States)

    Lukish, J R; Gill, G G; McCoy, T R

    2001-01-01

    To maintain the health of service members and their families throughout the world, the Department of Defense has established several isolated military hospitals (IHs). The operational environment of IHs is such that illness and traumatic injury requiring surgical intervention is common. This study sought to examine the general and orthopedic surgical experience at an IH to determine whether surgical care could be provided in an effective and safe manner. All patients evaluated by the general and orthopedic surgeon at Guantanamo Bay Naval Hospital from October 1, 1998, to April 1, 1999, were included in this study. The following data were retrospectively reviewed: patient demographic data, diagnosis, initial and follow-up care, medical evacuation data, operative procedures, and complications. There were 336 patients who presented for surgical evaluation, resulting in 660 follow-up appointments during the study period. There were 31 medical evacuations (3 emergent). The surgical services performed 122 major operative procedures. There were 58 inpatient admissions. There was 1 death, and surgical complications occurred in 2 patients, for an overall morbidity and mortality of 1.4% and 0.7%, respectively. Our data show that an IH is capable of providing surgical care, including care for traumatic injuries, in a safe manner. This is the first study that provides objective evidence that general and orthopedic surgery at an IH can be provided within the standard of care.

  13. Nanoscale Surface Photovoltage Mapping of 2D Materials and Heterostructures by Illuminated Kelvin Probe Force Microscopy

    KAUST Repository

    Shearer, Melinda J.

    2018-02-01

    Nanomaterials are interesting for a variety of applications, such as optoelectronics and photovoltaics. However, they often have spatial heterogeneity, i.e. composition change or physical change in the topography or structure, which can lead to varying properties that would influence their applications. New techniques must be developed to understand and correlate spatial heterogeneity with changes in electronic properties. Here we highlight the technique of surface photovoltage-Kelvin probe force microscopy (SPV-KFM), which is a modified version of non-contact atomic force microscopy capable of imaging not only the topography and surface potential, but also the surface photovoltage on the nanoscale. We demonstrate its utility in probing monolayer WSe2-MoS2 lateral heterostructures, which form an ultrathin p-n junction promising for photovoltaic and optoelectronic applications. We show surface photovoltage maps highlighting the different photoresponse of the two material regions as a result of the effective charge separation across this junction. Additionally, we study the variations between different heterostructure flakes and emphasize the importance of controlling the synthesis and transfer of these materials to obtain consistent properties and measurements.

  14. Nanoscale Surface Photovoltage Mapping of 2D Materials and Heterostructures by Illuminated Kelvin Probe Force Microscopy

    KAUST Repository

    Shearer, Melinda J.; Li, Ming-yang; Li, Lain-Jong; Jin, Song; Hamers, Robert J

    2018-01-01

    Nanomaterials are interesting for a variety of applications, such as optoelectronics and photovoltaics. However, they often have spatial heterogeneity, i.e. composition change or physical change in the topography or structure, which can lead to varying properties that would influence their applications. New techniques must be developed to understand and correlate spatial heterogeneity with changes in electronic properties. Here we highlight the technique of surface photovoltage-Kelvin probe force microscopy (SPV-KFM), which is a modified version of non-contact atomic force microscopy capable of imaging not only the topography and surface potential, but also the surface photovoltage on the nanoscale. We demonstrate its utility in probing monolayer WSe2-MoS2 lateral heterostructures, which form an ultrathin p-n junction promising for photovoltaic and optoelectronic applications. We show surface photovoltage maps highlighting the different photoresponse of the two material regions as a result of the effective charge separation across this junction. Additionally, we study the variations between different heterostructure flakes and emphasize the importance of controlling the synthesis and transfer of these materials to obtain consistent properties and measurements.

  15. Application of locked nucleic acid-based probes in fluorescence in situ hybridization

    DEFF Research Database (Denmark)

    Fontenete, Sílvia; Carvalho, Daniel R; Guimarães, Nuno

    2016-01-01

    of nucleic acid mimics used as mixmers in LNA-based probes strongly influence the efficiency of detection. LNA probes with 10 to 15 mers showed the highest efficiency. Additionally, the combination of 2′-OMe RNA with LNA allowed an increase on the fluorescence intensities of the probes. Overall......Fluorescence in situ hybridization (FISH) employing nucleic acid mimics as probes is becoming an emerging molecular tool in the microbiology area for the detection and visualization of microorganisms. However, the impact that locked nucleic acid (LNA) and 2′-O-methyl (2′-OMe) RNA modifications have...

  16. Surgical waste audit of 5 total knee arthroplasties.

    Science.gov (United States)

    Stall, Nathan M; Kagoma, Yoan M; Bondy, Jennifer N; Naudie, Douglas

    2013-04-01

    Operating rooms (ORs) are estimated to generate up to one-third of hospital waste. At the London Health Sciences Centre, prosthetics and implants represent 17% of the institution's ecological footprint. To investigate waste production associated with total knee arthroplasties (TKAs), we performed a surgical waste audit to gauge the environmental impact of this procedure and generate strategies to improve waste management. We conducted a waste audit of 5 primary TKAs performed by a single surgeon in February 2010. Waste was categorized into 6 streams: regular solid waste, recyclable plastics, biohazard waste, laundered linens, sharps and blue sterile wrap. Volume and weight of each stream was quantified. We used Canadian Joint Replacement Registry data (2008-2009) to estimate annual weight and volume totals of waste from all TKAs performed in Canada. The average surgical waste (excluding laundered linens) per TKA was 13.3 kg, of which 8.6 kg (64.5%) was normal solid waste, 2.5 kg (19.2%) was biohazard waste, 1.6 kg (12.1%) was blue sterile wrap, 0.3 kg (2.2%) was recyclables and 0.3 kg (2.2%) was sharps. Plastic wrappers, disposable surgical linens and personal protective equipment contributed considerably to total waste. We estimated that landfill waste from all 47 429 TKAs performed in Canada in 2008-2009 was 407 889 kg by weight and 15 272 m3 by volume. Total knee arthroplasties produce substantial amounts of surgical waste. Environmentally friendly surgical products and waste management strategies may allow ORs to reduce the negative impacts of waste production without compromising patient care. Level IV, case series.

  17. Cultural probes

    DEFF Research Database (Denmark)

    Madsen, Jacob Østergaard

    The aim of this study was thus to explore cultural probes (Gaver, Boucher et al. 2004), as a possible methodical approach, supporting knowledge production on situated and contextual aspects of occupation.......The aim of this study was thus to explore cultural probes (Gaver, Boucher et al. 2004), as a possible methodical approach, supporting knowledge production on situated and contextual aspects of occupation....

  18. Increased detectability of somatic changes in the DNA from human tumours after probing with "synthetic" and "genome-derived" hypervariable multilocus probes

    DEFF Research Database (Denmark)

    Lagoda, P J; Seitz, G; Epplen, J T

    1989-01-01

    intensities were observed. Together the probes 33.15 and (CAC)5/(GTG)5 detected deviating fingerprint patterns in 63% of the colorectal carcinomas investigated. In mammary and stomach carcinomas, only 1/11 and 2/11 tumours, respectively, showed differences with either of the three probes, 33.15, (GACA)4...

  19. Probing Photocatalytic Characteristics of Sb-Doped TiO2 under Visible Light Irradiation

    Directory of Open Access Journals (Sweden)

    Lingjing Luo

    2014-01-01

    Full Text Available Sb-doped TiO2 nanoparticle with varied dopant concentrations was synthesized using titanium tetrachloride (TiCl4 and antimony chloride (SbCl3 as the precursors. The properties of Sb-doped TiO2 nanoparticles were characterized by X-ray diffraction (XRD, scanning electron microscope (SEM, fluorescence spectrophotometer, and Uv-vis spectrophotometer. The absorption edge of TiO2 nanoparticles could be extended to visible region after doping with antimony, in contrast to the UV absorption of pure TiO2. The results showed that the photocatalytic activity of Sb-doped TiO2 nanoparticles was much more active than pure TiO2. The 0.1% Sb-doped TiO2 nanoparticles demonstrated the best photocatalytic activity which was better than that of the Degussa P25 under visible light irradiation using terephthalic acid as fluorescent probe. The effects of Sb dopant on the photocatalytic activity and the involved mechanism were extensively investigated in this work as well.

  20. Surgical Management of Recurrent Musculotendinous Hamstring Injury in Professional Athletes.

    Science.gov (United States)

    Sonnery-Cottet, Bertrand; Daggett, Matt; Gardon, Roland; Pupim, Barbara; Clechet, Julien; Thaunat, Mathieu

    2015-10-01

    Hamstring injury is the most common muscular lesion in athletes. The conservative treatment is well described, and surgical management is often indicated for proximal tendinous avulsions. To our knowledge, no surgical treatment has been proposed for failure of conservative treatment in musculotendinous hamstring lesions. To describe the surgical management of proximal and distal hamstring musculotendinous junction lesions in professional athletes after failure of conservative treatment. Case series; Level of evidence, 4. A consecutive series of 10 professional athletes, including 4 soccer players, 4 rugby players, and 2 handball players, underwent surgical intervention between October 2010 and June 2014 for the treatment of recurrent musculotendinous hamstring injuries. All athletes had failed at least 3 months of conservative treatment for a recurrent musculotendinous hamstring injury. Surgical resection of the musculotendinous scar tissue was performed using a longitudinal muscular suture. Lower Extremity Functional Scale (LEFS) and Marx scores were obtained at the 3-month follow-up, and a final phone interview was completed to determine recurrence of hamstring injury and return to previous level of play. The mean age at surgery was 25.2 years (range, 19-35 years). The musculotendinous hamstring lesions involved 8 semitendinosus and 2 biceps femoris, with 6 injuries located proximally and 4 distally. Conservative treatment lasted a mean 5.1 months (range, 3-9 months) after last recurrence, and the patients had an average of 2.7 (range, 2-5) separate incidents of injury recurrence before surgical intervention was decided upon. At the 3-month follow-up, all patients had Marx activity scores of 16 and LEFS scores of 80. All 10 patients returned to the same level of play at a mean 3.4 months (range, 2-5 months). At a mean follow-up of 28.7 months, none of the athletes had suffered a recurrence. No surgical complication was encountered. In cases of failed conservative

  1. Bacterial migration through punctured surgical gloves under real surgical conditions

    Directory of Open Access Journals (Sweden)

    Heidecke Claus-Dieter

    2010-07-01

    Full Text Available Abstract Background The aim of this study was to confirm recent results from a previous study focussing on the development of a method to measure the bacterial translocation through puncture holes in surgical gloves under real surgical conditions. Methods An established method was applied to detect bacterial migration from the operating site through the punctured glove. Biogel™ double-gloving surgical gloves were used during visceral surgeries over a 6-month period. A modified Gaschen-bag method was used to retrieve organisms from the inner glove, and thus-obtained bacteria were compared with micro-organisms detected by an intra-operative swab. Results In 20 consecutive procedures, 194 gloves (98 outer gloves, 96 inner gloves were examined. The rate of micro-perforations of the outer surgical glove was 10% with a median wearing time of 100 minutes (range: 20-175 minutes. Perforations occurred in 81% on the non-dominant hand, with the index finger most frequently (25% punctured. In six cases, bacterial migration could be demonstrated microbiologically. In 5% (5/98 of outer gloves and in 1% (1/96 of the inner gloves, bacterial migration through micro-perforations was observed. For gloves with detected micro-perforations (n = 10 outer layers, the calculated migration was 50% (n = 5. The minimum wearing time was 62 minutes, with a calculated median wearing time of 71 minutes. Conclusions This study confirms previous results that bacterial migration through unnoticed micro-perforations in surgical gloves does occur under real practical surgical conditions. Undetected perforation of surgical gloves occurs frequently. Bacterial migration from the patient through micro-perforations on the hand of surgeons was confirmed, limiting the protective barrier function of gloves if worn over longer periods.

  2. Defects in electron irradiated vitreous SiO[sub 2] probed by positron annihiliation

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Tanigawa, Shoichiro (Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science); Kawano, Takao (Tsukuba Univ., Ibaraki (Japan). Radioisotope Centre); Itoh, Hisayoshi (Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment)

    1994-10-10

    Defects in 3 MeV electron irradiated vitreous SiO[sub 2] (v-SiO[sub 2]) were probed by the positron annihilation technique. For unirradiated v-SiO[sub 2] specimens, almost all positrons were found to annihilate from positronium (Ps) states. This high formation probability of Ps was attributed to the trapping of positrons by open-space defects. The formation probability of Ps was decreased by the electron irradiation. The observed inhibition of the Ps formation was attributed to the trapping of positrons by point defects introduced and/or activated by the irradiation. From measurements of the lifetime distribution of Ps, it was found that, by the electron irradiation, the mean size of open-space defects was decreased and the size distribution of such defects was broadened. (Author).

  3. Miniature Flow-Direction/Pitot-Static Pressure Probes

    Science.gov (United States)

    Ashby, George C., Jr.; Coombs, David S.; Eves, John W.; Price, Howard E.; Vasquez, Peter

    1989-01-01

    Precision flow-direction/pitot-static pressure probes, ranging from 0.035 to 0.090 inch (0.89 to 2.29 mm) in outside diameter, successfully fabricated and calibrated for use in Langley 20-inch Mach 6 Tunnel. Probes simultaneously measure flow direction and static and pitot pressures in flow fields about configurations in hypersonic flow at temperatures up to 500 degree F (260 degree C).

  4. Impact of a structured surgical curriculum on ophthalmic resident cataract surgery complication rates.

    Science.gov (United States)

    Rogers, Gina M; Oetting, Thomas A; Lee, Andrew G; Grignon, Connie; Greenlee, Emily; Johnson, A Tim; Beaver, Hilary A; Carter, Keith

    2009-11-01

    To determine whether institution of a structured surgical curriculum for ophthalmology residents decreased the rate of sentinel surgical complications. Veterans Affairs Medical Center, Des Moines, Iowa, USA. A retrospective review was performed of third-year ophthalmic resident quality-assurance surgical outcomes data at a single residency-training site from 1998 to 2008. The primary outcome measure was defined as a sentinel event; that is, a posterior capsule tear (with or without vitreous loss) or vitreous loss (from any cause) occurring during a resident-performed case. The study population was divided into 2 groups. Group 1 comprised surgical cases of residents trained before the surgical curriculum change (academic years 1998 to 2003) and Group 2, surgical cases of residents trained with the enhanced curriculum (academic years 2004 to 2008). Data from 1 year (academic year 2003 to 2004) were excluded because the transition to the enhanced curriculum occurred during that period. The data were analyzed and adjusted for surgical experience. In Group 1 (before institution of surgical curriculum), there were 823 cases with 59 sentinel complications. In Group 2 (after institution of surgical curriculum), there were 1009 cases with 38 sentinel complications. There was a statistically significant reduction in the sentinel complication rate, from 7.17% before the curriculum changes to 3.77% with the enhanced curriculum (P = .001, unpaired 2-tailed t test). Implementation of a structured surgical curriculum resulted in a statistically significant reduction in sentinel event complications, even after adjusting for surgical experience.

  5. Surgical experts: born or made?

    Science.gov (United States)

    Sadideen, Hazim; Alvand, Abtin; Saadeddin, Munir; Kneebone, Roger

    2013-01-01

    The concept of surgical expertise and the processes involved in its development are topical, and there is a constant drive to identify reliable measures of expert performance in surgery. This review explores the notion of whether surgical experts are "born" or "made", with reference to educational theory and pertinent literature. Peer-reviewed publications, books, and online resources on surgical education, expertise and training were reviewed. Important themes and aspects of expertise acquisition were identified in order to better understand the concept of a surgical expert. The definition of surgical expertise and several important aspects of its development are highlighted. Innate talent plays an important role, but is insufficient on its own to produce a surgical expert. Multiple theories that explore motor skill acquisition and memory are relevant, and Ericsson's theory of the development of competence followed by deliberate self-practice has been especially influential. Psychomotor and non-technical skills are necessary for progression in the current climate in light of our training curricula; surgical experts are adaptive experts who excel in these. The literature suggests that surgical expertise is reached through practice; surgical experts are made, not born. A deeper understanding of the nature of expert performance and its development will ensure that surgical education training programmes are of the highest possible quality. Surgical educators should aim to develop an expertise-based approach, with expert performance as the benchmark. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Surgical Safety Training of World Health Organization Initiatives.

    Science.gov (United States)

    Davis, Christopher R; Bates, Anthony S; Toll, Edward C; Cole, Matthew; Smith, Frank C T; Stark, Michael

    2014-01-01

    Undergraduate training in surgical safety is essential to maximize patient safety. This national review quantified undergraduate surgical safety training. Training of 2 international safety initiatives was quantified: (1) World Health Organization (WHO) "Guidelines for Safe Surgery" and (2) Department of Health (DoH) "Principles of the Productive Operating Theatre." Also, 13 additional safety skills were quantified. Data were analyzed using Mann-Whitney U tests. In all, 23 universities entered the study (71.9% response). Safety skills from WHO and DoH documents were formally taught in 4 UK medical schools (17.4%). Individual components of the documents were taught more frequently (47.6%). Half (50.9%) of the additional safety skills identified were taught. Surgical societies supplemented safety training, although the total amount of training provided was less than that in university curricula (P < .0001). Surgical safety training is inadequate in UK medical schools. To protect patients and maximize safety, a national undergraduate safety curriculum is recommended. © 2013 by the American College of Medical Quality.

  7. Dual-probe decoherence microscopy: probing pockets of coherence in a decohering environment

    International Nuclear Information System (INIS)

    Jeske, Jan; Cole, Jared H; Müller, Clemens; Marthaler, Michael; Schön, Gerd

    2012-01-01

    We study the use of a pair of qubits as a decoherence probe of a nontrivial environment. This dual-probe configuration is modelled by three two-level systems (TLSs), which are coupled in a chain in which the middle system represents an environmental TLS. This TLS resides within the environment of the qubits and therefore its coupling to perturbing fluctuations (i.e. its decoherence) is assumed much stronger than the decoherence acting on the probe qubits. We study the evolution of such a tripartite system including the appearance of a decoherence-free state (dark state) and non-Markovian behaviour. We find that all parameters of this TLS can be obtained from measurements of one of the probe qubits. Furthermore, we show the advantages of two qubits in probing environments and the new dynamics imposed by a TLS that couples to two qubits at once. (paper)

  8. Improved controlled atmosphere high temperature scanning probe microscope

    DEFF Research Database (Denmark)

    Hansen, Karin Vels; Wu, Yuehua; Jacobsen, Torben

    2013-01-01

    fuel cells and electrolyzer cells. Here, we report on advanced improvements of our original controlled atmosphere high temperature scanning probe microscope, CAHT-SPM. The new microscope can employ a broad range of the scanning probe techniques including tapping mode, scanning tunneling microscopy......, scanning tunneling spectroscopy, conductive atomic force microscopy, and Kelvin probe force microscopy. The temperature of the sample can be as high as 850 °C. Both reducing and oxidizing gases such as oxygen, hydrogen, and nitrogen can be added in the sample chamber and the oxygen partial pressure (pO2...

  9. Radiation exposure to surgical staff during F-18-FDG-guided cancer surgery

    International Nuclear Information System (INIS)

    Andersen, P.A.; Hesse, B.; Chakera, A.H.; Schmidt, G.; Klausen, T.L.; Binderup, T.; Grossjohann, H.S.; Friis, E.; Hansen, C.P.; Kjaer, A.

    2008-01-01

    High-energy gamma probes have recently become commercially available, developed for 18 F-FDG probe-guided surgery. The radiation received by the staff in the operating room might limit the use of it, but has never been determined. We therefore wanted to measure the absorbed staff doses at operations where patients had received a preoperative injection of 18 F-FDG. Thirty-four patients with different cancers (breast cancer, melanoma, gastrointestinal cancers, respectively) were operated. At every operation the surgeon was monitored with a TLD tablet on his finger of the operating hand and a TLD tablet on the abdomen. The surgeon and anaesthesiologist were also monitored using electronic dosimeters placed in the trousers lining at 25 operations. The dose rate to the surgeon's abdominal wall varied between 7.5-13.2 μSv/h, depending on tumour location. The doses to the anaesthesiologists and the finger doses to the surgeon were much lower. About 350-400 MBq, i.e. ca. eight times higher activities than those used in the present study are supposed to be necessary for guiding surgery. It can be calculated from the body doses measured that a surgeon can perform between 150-260 h of surgery without exceeding permissible limits for professional workers. The radiation load to the operating staff will generally be so small that it does not present any limitation for FDG-guided surgery. However, it is recommended to monitor the surgical staff considering that the surgeon may be exposed to other radiation sources, and since the staff often includes women of child-bearing age. (orig.)

  10. Expanding probe repertoire and improving reproducibility in human genomic hybridization

    Science.gov (United States)

    Dorman, Stephanie N.; Shirley, Ben C.; Knoll, Joan H. M.; Rogan, Peter K.

    2013-01-01

    Diagnostic DNA hybridization relies on probes composed of single copy (sc) genomic sequences. Sc sequences in probe design ensure high specificity and avoid cross-hybridization to other regions of the genome, which could lead to ambiguous results that are difficult to interpret. We examine how the distribution and composition of repetitive sequences in the genome affects sc probe performance. A divide and conquer algorithm was implemented to design sc probes. With this approach, sc probes can include divergent repetitive elements, which hybridize to unique genomic targets under higher stringency experimental conditions. Genome-wide custom probe sets were created for fluorescent in situ hybridization (FISH) and microarray genomic hybridization. The scFISH probes were developed for detection of copy number changes within small tumour suppressor genes and oncogenes. The microarrays demonstrated increased reproducibility by eliminating cross-hybridization to repetitive sequences adjacent to probe targets. The genome-wide microarrays exhibited lower median coefficients of variation (17.8%) for two HapMap family trios. The coefficients of variations of commercial probes within 300 nt of a repetitive element were 48.3% higher than the nearest custom probe. Furthermore, the custom microarray called a chromosome 15q11.2q13 deletion more consistently. This method for sc probe design increases probe coverage for FISH and lowers variability in genomic microarrays. PMID:23376933

  11. Automated design of genomic Southern blot probes

    Directory of Open Access Journals (Sweden)

    Komiyama Noboru H

    2010-01-01

    experimentally validate a number of these automated designs by Southern blotting. The majority of probes we tested performed well confirming our in silico prediction methodology and the general usefulness of the software for automated genomic Southern probe design. Conclusions Software and supplementary information are freely available at: http://www.genes2cognition.org/software/southern_blot

  12. Calix[2]pyreno[2]pyrrole as a Fluorescence Chemical Probe for Polynitroaromatics

    International Nuclear Information System (INIS)

    Park, Kyung Hwa; Yoo, Jae Duk; Lee, Chang Hee; Ka, Jae Won

    2012-01-01

    We have demonstrated that the new, readily synthesized and well characterized calix pyreno pyrrole fluorescence molecular probe can detect polynitroaromatic compounds with high affinity. In addition, this highly fluorescent neutral molecular receptor also exhibits enhanced binding affinity towards TNT which is associated with the formation of a pi-complex. The dynamic nature of the current system may enable it to serve as an excellent scaffold for electron-deficient guest molecular binding. Studies for other neutral molecules including metal ions are under in active progress. The elevated selectivity and sensitivity for specific analytes are the core requirements for an ideal chemical probes. A signal induced by guest binding must be sensitive enough so that accurate real time monitoring could be satisfactorily achieved. Introduction of signaling units at suitable places in which they can directly interact with the recognition events is critical in designing chemosensors. Among various signaling events, fluorescence changes are often applied for the sensitive detection of various analytes. An easy modulation of the photochemical properties of the signaling units is an additional advantage in compatibility and applications. Chemosensors for the detection of explosives becomes important due to their immediate applications in remedation of explosive manufacturing sites, homeland security or forensic sciences. With that in mind, numerous methods for the explosive detection have been reported in recent years. Nevertheless, some detection methods sometimes require sophisticated instrumentation which is not easy for on-site testing

  13. Surgical abdomen in patients with nephrotic syndrome: complexities of differential diagnostics. 2 case reports

    OpenAIRE

    Nogaibayeva, A.; Moldakhmetova, S.; Tuganbekova, S.; Krivoruchko, N.

    2014-01-01

    INTROduCTIONANdAIMS: Differential-diagnostic search is very important at the stage of abdominal nephrotic crisis for determination of therapy tactics; as the probability of development of acute surgical pathology is very high, due to connection of infectious complications on a background of the basic pathology and immunosupression. We report 2 patients with acute onset of abdominal pain on a background of severe nephrotic syndrome (NS). METHOdS: Case 1: 20-years old man with bioptic diagnosis...

  14. Model for resonant plasma probe.

    Energy Technology Data Exchange (ETDEWEB)

    Warne, Larry Kevin; Johnson, William Arthur; Hebner, Gregory Albert; Jorgenson, Roy E.; Coats, Rebecca Sue

    2007-04-01

    This report constructs simple circuit models for a hairpin shaped resonant plasma probe. Effects of the plasma sheath region surrounding the wires making up the probe are determined. Electromagnetic simulations of the probe are compared to the circuit model results. The perturbing effects of the disc cavity in which the probe operates are also found.

  15. Development of X-ray mini-probes for the Digiray RGX system

    International Nuclear Information System (INIS)

    Wojcik, R.; Kross, B.; Majewski, L.; Majewski, S.; Weisenberger, A.G.; Zorn, C.; Birt, E.A.; Parker, F.R.; Winfree, W.P.; Albert, R.D.; Albert, T.M.

    1994-01-01

    We have developed and tested a variety of X-ray mini-probes for the Reverse Geometry X-radiography trademark ,1 (RGX) system each having their own advantages and disadvantages. These mini-probes consist of small scintillators (as small as 2 mm in diameter and 5 mm long) attached to optical light guides (as long as 14 m) coupled to photomultipliers. Images produced with these probes show that even smaller probes and/or longer light guides may be fashioned. Such probes may be useful in both non-destructive evaluation and medical imaging. ((orig.))

  16. Weight loss maintenance in overweight subjects on ad libitum diets with high or low protein content and glycemic index

    DEFF Research Database (Denmark)

    Aller, E E J G; Larsen, Thomas Meinert; Holst, Claus

    2014-01-01

    Background:A high dietary protein (P) content and low glycemic index (GI) have been suggested to be beneficial for weight management, but long-term studies are scarce.Objective:The DIOGENES randomized clinical trial investigated the effect of P and GI on weight loss maintenance in overweight...... or obese adults in 8 centers across Europe. This study reports the 1-year results in 2 of the centers that extended the intervention to 1 year.Method:After an 8-week low calorie diet (LCD), 256 adults (BMI>27 kg/m(2)) were randomized to 5 ad libitum diets for 12 months: high P/low GI (HP/LGI), high P/high...... GI (HP/HGI), low P/low GI (LP/LGI), low P/high GI (LP/HGI) and a control diet. During the first 6 months foods were provided for free through a shop system, during the whole 12-month period subjects received guidance by a dietician. Primary outcome variable was the change in body weight over the 12...

  17. Global curriculum in surgical oncology.

    Science.gov (United States)

    Are, C; Berman, R S; Wyld, L; Cummings, C; Lecoq, C; Audisio, R A

    2016-06-01

    The significant global variations in surgical oncology training paradigms can have a detrimental effect on tackling the rising global cancer burden. While some variations in training are essential to account for the differences in types of cancer and biology, the fundamental principles of providing care to a cancer patient remain the same. The development of a global curriculum in surgical oncology with incorporated essential standards could be very useful in building an adequately trained surgical oncology workforce, which in turn could help in tackling the rising global cancer burden. The leaders of the Society of Surgical Oncology and European Society of Surgical Oncology convened a global curriculum committee to develop a global curriculum in surgical oncology. A global curriculum in surgical oncology was developed to incorporate the required domains considered to be essential in training a surgical oncologist. The curriculum was constructed in a modular fashion to permit flexibility to suit the needs of the different regions of the world. Similarly, recognizing the various sociocultural, financial and cultural influences across the world, the proposed curriculum is aspirational and not mandatory in intent. A global curriculum was developed which may be considered as a foundational scaffolding for training surgical oncologists worldwide. It is envisioned that this initial global curriculum will provide a flexible and modular scaffolding that can be tailored by individual countries or regions to train surgical oncologists in a way that is appropriate for practice in their local environment. Copyright © 2016 Society of Surgical Oncology, European Society of Surgical Oncology. Published by Elsevier Ltd.. All rights reserved.

  18. Editor's Choice - Late Open Surgical Conversion after Endovascular Abdominal Aortic Aneurysm Repair.

    Science.gov (United States)

    Kansal, Vinay; Nagpal, Sudhir; Jetty, Prasad

    2018-02-01

    Late open surgical conversion following endovascular aneurysm repair (EVAR) may occur more frequently after performing EVAR in anatomy outside the instructions for use (IFU). This study reviews predictors and outcomes of late open surgical conversion for failed EVAR. This retrospective cohort study reviewed all EVARs performed at the Ottawa Hospital between January 1999 and May 2015. Open surgical conversions >1 month post EVAR were identified. Variables analysed included indication for conversion, pre-intervention AAA anatomy, endovascular device and configuration, operative technique, re-interventions, complications, and death. Of 1060 consecutive EVARs performed, 16 required late open surgical conversion. Endografts implanted were Medtronic Talent (n = 8, 50.0%), Medtronic Endurant (n = 3, 18.8%), Cook Zenith (n = 4, 25.0%), and Terumo Anaconda (n = 1, 6.2%). Eleven grafts were bifurcated (68.8%), five were aorto-uni-iliac (31.2%). The median time to open surgical conversion was 3.1 (IQR 1.0-5.2) years. There was no significant difference in pre-EVAR rupture status (1.4% elective, 2.1% ruptured, p = .54). Indications for conversion included: Type 1 endoleak with sac expansion (n = 4, 25.0%), Type 2 endoleak with expansion (n = 2, 12.5%), migration (n = 3, 18.8%), sac expansion without endoleak (n = 2, 12.5%), graft infection (n = 3, 18.8%), rupture (n = 2, 12.5%). Nine patients (56.2%) underwent stent graft explantation with in situ surgical graft reconstruction, seven had endograft preserving open surgical intervention. The 30 day mortality was 18.8% (n = 3, all of whom having had endograft preservation). Ten patients (62.5%) suffered major in hospital complications. One patient (6.5%) required post-conversion major surgical re-intervention. IFU adherence during initial EVAR was 43.8%, versus 79.0% (p Open surgical conversion following EVAR results in significant morbidity and mortality. IFU adherence of EVARs later requiring open surgical

  19. Design and application of noncontinuously binding probes used for haplotyping and genotyping.

    Science.gov (United States)

    Pont-Kingdon, Genevieve; Margraf, Rebecca L; Sumner, Kelli; Millson, Alison; Lyon, Elaine; Schütz, Ekkehard

    2008-06-01

    Many methods for genotyping use melting temperature (Tm) of sequence-specific probes. Usually the probes hybridize to a continuous stretch of DNA that contains the variant(s). In contrast, hybridization of noncontinuous probes to a template can form bulges. This report generates guidelines for the design of noncontinuous probes. We used software to predict hybridization structures and Tms from 10 noncontinuous probes and 54 different templates. Predicted Tms were compared to existing experimental data. The bulging template's sequences (omitted in the probe) ranged in size from 1 to 73 nucleotides. In 36 cases, we compared observed and predicted DeltaTms between alleles complementary to the probe and mismatched alleles. In addition, using software that predicts effects of bulges, we designed a probe and then tested it experimentally. The mean differences between predicted and observed Tms were 0.65 (2.51) degrees C with the Visual OMP software and 0.28 (1.67) degrees C with the MeltCalc software. DeltaTms were within a mean (SD) of 0.36 (1.23) degrees C (Visual OMP) and -0.01 (1.02) degrees C (MeltCalc) of observed values. An increase in the size of the template bulge resulted in a decrease in Tms. In 2 templates, the presence of a variant in the bulge influenced the experimental Tm of 2 noncontinuous probes, a result that was not predicted by the software programs. The use of software prediction should prove useful for the design of noncontinuous probes that can be used as tools for molecular haplotyping, multiplex genotyping, or masking sequence variants.

  20. Capping of the radicular exposed surface (part II). Surgical and not surgical treatment

    OpenAIRE

    Grados Pomarino, Sixto; Estrada, Andrew Alejandro; Maetahara Rubio, Denis Miguel; Guzmán Vera, Yanina Sara; Tello Barbarán, Javier

    2014-01-01

    The gingival recession treatment can be made surgical1y with a high predictability of success due to the great advance during the last ones of the mucogingival surgical techniques. The use of connective grafts in coverage of recessions has obtained high rates of success reason why these procedures are common within the modern periodontal surgical practice. Knowing that all patients do not accept the surgical treatment, many investigators have come studying the possibility of treating non-surg...

  1. Characterization of near-field optical probes

    DEFF Research Database (Denmark)

    Vohnsen, Brian; Bozhevolnyi, Sergey I.

    1999-01-01

    Radiation and collection characteristics of four different near-field optical-fiber probes, namely, three uncoated probes and an aluminium-coated small-aperture probe, are investigated and compared. Their radiation properties are characterized by observation of light-induced topography changes...... in a photo-sensitive film illuminated with the probes, and it is confirmed that the radiated optical field is unambigiously confined only for the coated probe. Near-field optical imaging of a standing evanescent-wave pattern is used to compare the detection characteristics of the probes, and it is concluded...... that, for the imaging of optical-field intensity distributions containing predominantly evanescent-wave components, a sharp uncoated tip is the probe of choice. Complementary results obtained with optical phase-conjugation experiments with he uncoated probes are discussed in relation to the probe...

  2. Sensing lymphoma cells based on a cell-penetrating/apoptosis-inducing/electron-transfer peptide probe

    International Nuclear Information System (INIS)

    Sugawara, Kazuharu; Shinohara, Hiroki; Kadoya, Toshihiko; Kuramitz, Hideki

    2016-01-01

    To electrochemically sense lymphoma cells (U937), we fabricated a multifunctional peptide probe that consists of cell-penetrating/apoptosis-inducing/electron-transfer peptides. Electron-transfer peptides derive from cysteine residue combined with the C-terminals of four tyrosine residues (Y_4). A peptide whereby Y_4C is bound to the C-terminals of protegrin 1 (RGGRLCYCRRRFCVCVGR-NH_2) is known to be an apoptosis-inducing agent against U937 cells, and is referred to as a peptide-1 probe. An oxidation response of the peptide-1 probe has been observed due to a phenolic hydroxyl group, and this response is decreased by the uptake of the peptide probe into the cells. To improve the cell membrane permeability against U937 cells, the RGGR at the N-terminals of the peptide-1 probe was replaced by RRRR (peptide-2 probe). In contrast, RNRCKGTDVQAWY_4C (peptide-3 probe), which recognizes ovalbumin, was constructed as a control. Compared with the other probes, the change in the peak current of the peptide-2 probe was the greatest at low concentrations and occurred in a short amount of time. Therefore, the cell membrane permeability of the peptide-2 probe was increased based on the arginine residues and the apoptosis-inducing peptides. The peak current was linear and ranged from 100 to 1000 cells/ml. The relative standard deviation of 600 cells/ml was 5.0% (n = 5). Furthermore, the membrane permeability of the peptide probes was confirmed using fluorescent dye. - Highlights: • We constructed a multifunctional peptide probe for the electrochemical sensing of lymphoma cells. • The peptide probe consists of cell-penetrating/apoptosis-inducing/electron-transfer peptides. • The electrode response of the peptide probe changes due to selective uptake into the cells.

  3. Sensing lymphoma cells based on a cell-penetrating/apoptosis-inducing/electron-transfer peptide probe

    Energy Technology Data Exchange (ETDEWEB)

    Sugawara, Kazuharu, E-mail: kzsuga@maebashi-it.ac.jp [Maebashi Institute of Technology, Gunma 371-0816 (Japan); Shinohara, Hiroki; Kadoya, Toshihiko [Maebashi Institute of Technology, Gunma 371-0816 (Japan); Kuramitz, Hideki [Department of Environmental Biology and Chemistry, Graduate School of Science and Engineering for Research, University of Toyama, Toyama 930-8555 (Japan)

    2016-06-14

    To electrochemically sense lymphoma cells (U937), we fabricated a multifunctional peptide probe that consists of cell-penetrating/apoptosis-inducing/electron-transfer peptides. Electron-transfer peptides derive from cysteine residue combined with the C-terminals of four tyrosine residues (Y{sub 4}). A peptide whereby Y{sub 4}C is bound to the C-terminals of protegrin 1 (RGGRLCYCRRRFCVCVGR-NH{sub 2}) is known to be an apoptosis-inducing agent against U937 cells, and is referred to as a peptide-1 probe. An oxidation response of the peptide-1 probe has been observed due to a phenolic hydroxyl group, and this response is decreased by the uptake of the peptide probe into the cells. To improve the cell membrane permeability against U937 cells, the RGGR at the N-terminals of the peptide-1 probe was replaced by RRRR (peptide-2 probe). In contrast, RNRCKGTDVQAWY{sub 4}C (peptide-3 probe), which recognizes ovalbumin, was constructed as a control. Compared with the other probes, the change in the peak current of the peptide-2 probe was the greatest at low concentrations and occurred in a short amount of time. Therefore, the cell membrane permeability of the peptide-2 probe was increased based on the arginine residues and the apoptosis-inducing peptides. The peak current was linear and ranged from 100 to 1000 cells/ml. The relative standard deviation of 600 cells/ml was 5.0% (n = 5). Furthermore, the membrane permeability of the peptide probes was confirmed using fluorescent dye. - Highlights: • We constructed a multifunctional peptide probe for the electrochemical sensing of lymphoma cells. • The peptide probe consists of cell-penetrating/apoptosis-inducing/electron-transfer peptides. • The electrode response of the peptide probe changes due to selective uptake into the cells.

  4. Optimization of the extent of surgical treatment in patients with stage I in cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, A. L.; Lyapunov, A. Yu., E-mail: Lyapunov1720.90@mail.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Kolomiets, L. A. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Siberian State Medical University, Moskovsky Trakt 2, Tomsk, 634050 (Russian Federation); Sinilkin, I. G.; Chernov, V. I. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The study included 26 patients with FIGO stage Ia1–Ib1 cervical cancer who underwent fertility-sparing surgery (transabdominaltrachelectomy). To visualize sentinel lymph nodes, lymphoscintigraphy with injection of 99mTc-labelled nanocolloid was performed the day before surgery. Intraoperative identification of sentinel lymph nodes using hand-held gamma probe was carried out to determine the radioactive counts over the draining lymph node basin. The sentinel lymph node detection in cervical cancer patients contributes to the accurate clinical assessment of the pelvic lymph node status, precise staging of the disease and tailoring of surgical treatment to individual patient.

  5. Measuring the Burden of Surgical Disease Averted by Emergency and Essential Surgical Care in a District Hospital in Papua New Guinea.

    Science.gov (United States)

    Stokes, Matthew A R; Guest, Glenn D; Mamadi, Perista; Seta, Westin; Yaubihi, Noel; Karawiga, Grace; Naidi, Billy; Watters, David A K

    2017-03-01

    Timely access to emergency and essential surgical care (EESC) and anaesthesia in low- and middle-income countries (LMICs) prevents premature death, minimises lifelong disability and reduces their economic impact on families and communities. Papua New Guinea is one of the poorest countries in the Pacific region, and provides much of its surgical care at a district hospital level. We aimed to evaluate the surgical capacity of a district hospital in PNG and estimate the effectiveness of surgical interventions provided. We performed a prospective study to calculate the number of DALYs averted for 465 patients treated with surgical care over a 3-month period (Sep-Nov 2013) in Alotau Hospital, Milne Bay Province, PNG (pop 210,000). Data were also collected on infrastructure, workforce, interventions provided and equipment available using the World Health Organization's Integrated Management of Emergency and Essential Surgical Care Toolkit, a survey to assess EESC and surgical capacity. We also performed a retrospective one-year audit of surgical, obstetric and anaesthetic care to provide context with regards to annual disease burden treated and surgical activity. EESC was provided by 11 Surgeons/Anaesthetists/Obstetricians (SAO) providers, equating to 5.7 per 100,000 population (including 4 nurse anaesthetists). They performed 783/100,000 procedures annually. Over the 3-month prospective study period, 4954 DALYs were averted by 465 surgical interventions, 52 % of which were elective. This equates to 18,330 DALYs averted annually or, approximately 18 % of the published but estimated disease burden in the Province in the 2013 Global Burden of Disease Study. The overall peri-operative mortality rate was 1.29 %, with 0.41 % for elective procedures and 2.25 % for emergencies. Much of the burden of surgical disease in Papua New Guinea presenting to Alotau General Hospital serving Milne Bay Province can be effectively treated by a small team providing emergency and

  6. Molecular Imaging of Hepatocellular Carcinoma Xenografts with Epidermal Growth Factor Receptor Targeted Affibody Probes

    Directory of Open Access Journals (Sweden)

    Ping Zhao

    2013-01-01

    Full Text Available Hepatocellular carcinoma (HCC is a highly aggressive and lethal cancer. It is typically asymptomatic at the early stage, with only 10%–20% of HCC patients being diagnosed early enough for appropriate surgical treatment. The delayed diagnosis of HCC is associated with limited treatment options and much lower survival rates. Therefore, the early and accurate detection of HCC is crucial to improve its currently dismal prognosis. The epidermal growth factor receptor (EGFR has been reported to be involved in HCC tumorigenesis and to represent an attractive target for HCC imaging and therapy. In this study, an affibody molecule, Ac-Cys-ZEGFR:1907, targeting the extracellular domain of EGFR, was used for the first time to assess its potential to detect HCC xenografts. By evaluating radio- or fluorescent-labeled Ac-Cys-ZEGFR:1907 as a probe for positron emission tomography (PET or optical imaging of HCC, subcutaneous EGFR-positive HCC xenografts were found to be successfully imaged by the PET probe. Thus, affibody-based PET imaging of EGFR provides a promising approach for detecting HCC in vivo.

  7. IL-6 RESPONSES TO GLYCAEMIC INDEX DURING RECOVERY FROM EXERCISE

    Directory of Open Access Journals (Sweden)

    S.H. Hasani

    2015-06-01

    Full Text Available Purpose: This study examined the effect of meal with different glycaemic index (GI on plasma IL-6 concentration and glucose metabolism after maximal lengthening contractions of the knee extensors. Using a cross-over design, Material : 10 healthy males completed 5 sets of 10 lengthening (eccentric contractions at 120% 1 repetition-maximum. Subjects were randomized to consume the GI beverage (high-GI, low-GI (15% weight per volume; 3 g/kg BM or placebo in three times within 10 min following exercise, and again at 50 and 110 min during recovery time. Blood samples were collected before exercise and after 0.60, 180 min and 24 h of recovery. Results: Concentration of plasma IL-6 in HGI group was less than LGI and Pla groups. IL-6 tended to significantly increase after exercise in recovery time in 3 groups (all P < 0.05, except for 24 hours (P = 1.00, furthermore there was significant difference for IL-6 between placebo and high glycemic groups in 3hours after exercise (P=.016. Concentration of serum CK in HGI group was less than LGI and Pla groups, CK was significantly elevated at all times points during recovery in 3 groups (all P < 0.05, except for 1 hour after exercise in HGI group (P = 0.31, but there was no significant difference for CK between groups. Conclusion: In summary, consuming HGI carbohydrate during recovery from exercise attenuate plasma IL-6 concentration.

  8. Luminescence recognition of different organophosphorus pesticides by the luminescent Eu(III)–pyridine-2,6-dicarboxylic acid probe

    International Nuclear Information System (INIS)

    Azab, Hassan A.; Duerkop, Axel; Anwar, Z.M.; Hussein, Belal H.M.; Rizk, Moustafa A.; Amin, Tarek

    2013-01-01

    Highlights: ► Europium (III) luminescence quenching has been used for sensing organophosphorous pesticides. ► Four guest pesticides chlorfenvinphos, malathion, azinphos, and paraxon ethyl were used. ► A sensitive rapid, cheap direct method for the determination of the pesticides has been developed. ► The method was applied to the determination of the OPs in tap, river, mineral, and waste waters. - Abstract: Luminescence quenching of a novel long lived Eu(III)–pyridine-2,6-dicarboxylic acid probe of 1:2 stoichiometric ratio has been studied in 0.10 volume fraction ethanol–water mixture at pH 7.5 (HEPES buffer) in the presence of the organophosphorus pesticides chlorfenvinphos (P1), malathion (P2), azinphos (P3), and paraxon ethyl (P4). The luminescence intensity of Eu(III)–(PDCA) 2 probe decreases as the concentration of the pesticide increases. It was observed that the quenching due to P3 and P4 proceeds via both diffusional and static quenching processes. Direct methods for the determination of the pesticides under investigation have been developed using the luminescence quenching of Eu(III)–pyridine-2,6-dicarboxylic acid probe in solution. The linear range for determination of the selected pesticides is 1.0–35.0 μM. The detection limits were 0.24–0.55 μM for P3, P4, and P1 and 2.5 μM for P2, respectively. The binding constants (K), and thermodynamic parameters of the OPs with Eu(III)–(PDCA) 2 were evaluated. Positive and negative values of entropy (ΔS) and enthalpy (ΔH) changes for Eu(III)–(PDCA) 2 –P1 ternary complex were calculated. As the waters in this study do not contain the above mentioned OPs over the limit detectable by the method, a recovery study was carried out after the addition of the adequate amounts of the organophosphorus pesticides under investigation.

  9. Peer-assisted teaching of basic surgical skills.

    Science.gov (United States)

    Preece, Ryan; Dickinson, Emily Clare; Sherif, Mohamed; Ibrahim, Yousef; Ninan, Ann Susan; Aildasani, Laxmi; Ahmed, Sartaj; Smith, Philip

    2015-01-01

    Basic surgical skills training is rarely emphasised in undergraduate medical curricula. However, the provision of skills tutorials requires significant commitment from time-constrained surgical faculty. We aimed to determine how a peer-assisted suturing workshop could enhance surgical skills competency among medical students and enthuse them towards a career in surgery. Senior student tutors delivered two suturing workshops to second- and third- year medical students. Suturing performance was assessed before and after teaching in a 10-min suturing exercise (variables measured included number of sutures completed, suture tension, and inter-suture distance). Following the workshop, students completed a questionnaire assessing the effect of the workshop on their suturing technique and their intention to pursue a surgical career. Thirty-five students attended. Eighty-one percent believed their medical school course provided insufficient basic surgical skills training. The mean number of sutures completed post-teaching increased significantly (p teaching, to ± 2.6 mm post-teaching. All students found the teaching environment to be relaxed, and all felt the workshop helped to improve their suturing technique and confidence; 87% found the peer-taught workshop had increased their desire to undertake a career in surgery. Peer-assisted learning suturing workshops can enhance medical students' competence with surgical skills and inspire them towards a career in surgery. With very little staff faculty contribution, it is a cheap and sustainable way to ensure ongoing undergraduate surgical skills exposure.

  10. Surgical management of giant posterior communicating artery aneurysms.

    Science.gov (United States)

    Velat, Gregory J; Zabramski, Joseph M; Nakaji, Peter; Spetzler, Robert F

    2012-09-01

    Giant posterior communicating artery (PCoA) aneurysms (> 25 mm) are rare lesions associated with a poor prognosis and high rates of morbidity and mortality. To review the clinical results of giant PCoA aneurysms surgically treated at our institution, focusing on operative nuances. All cases of giant PCoA aneurysms treated surgically at our institution were identified from a prospectively maintained patient database. Patient demographic factors, medical comorbidities, rupture status, neurological presentation, clinical outcomes, and surgical records were critically reviewed. From 1989 to 2010, 11 patients (10 women) underwent surgical clipping of giant PCoA aneurysms. Presenting signs and symptoms included cranial nerve palsies, diminished mental status, headache, visual changes, and seizures. Five aneurysms were ruptured on admission. All aneurysms were clipped primarily except 1, which was treated by parent artery sacrifice and extracranial-to-intracranial bypass after intraoperative aneurysm rupture. Perioperative morbidity and mortality rates were 36% (4 of 11) and 18.3% (2 of 11), respectively. Excellent or good clinical outcomes, defined as modified Rankin Scale scores ≤ 2, were achieved in 86% (5 of 6) of patients available for long-term clinical follow-up (mean, 12.5 ± 13.6 months). Giant PCoA aneurysms are rare vascular lesions that may present with a variety of neurological signs and symptoms. These lesions can be successfully managed surgically with satisfactory morbidity and mortality rates. To the best of our knowledge, this is the largest surgical series of giant PCoA aneurysms published to date.

  11. Probing the stability of Al 2O 3/Ge structures with ion beams

    Science.gov (United States)

    Bom, N. M.; Soares, G. V.; Krug, C.; Baumvol, I. J. R.; Radtke, C.

    2012-02-01

    Al 2O 3 films were deposited on Ge substrates by reactive sputtering. Resulting samples were submitted to different post-deposition annealings (PDAs) in order to probe composition modifications induced by such treatments. Nuclear reaction profiling (NRP) revealed that O incorporation depends on PDA temperature and on the employed atmosphere (water or oxygen). We also found that O from the gas phase strongly interacts with the Ge semiconductor substrate when PDA is performed with water at 500 °C. Ion scattering analyses evidenced an increase of Ge concentration throughout the Al 2O 3 dielectric layer and on the sample surface associated with the oxidation of the Ge substrate. These findings are explained by GeO desorption resulting from chemical reactions occurring at the dielectric/Ge interface.

  12. Abortion - surgical - aftercare

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000658.htm Abortion - surgical - aftercare To use the sharing features on ... please enable JavaScript. You have had a surgical abortion. This is a procedure that ends pregnancy by ...

  13. Design and performance of low-wattage electrical heater probe

    International Nuclear Information System (INIS)

    Biddle, R.; Wetzel, J.R.; Cech, R.

    1997-01-01

    A mound electrical calibration heater (MECH) has been used in several EG and G Mound developed calorimeters as a calibration tool. They are very useful over the wattage range of a few to 500 W. At the lower end of the range, a bias develops between the MECH probe and calibrated heat standards. A low-wattage electrical calibration heater (L WECH) probe is being developed by the Safeguards Science and Technology group (NIS-5) of Los Alamos National Laboratory based upon a concept proposed by EG and G Mound personnel. The probe combines electrical resistive heating and laser-light powered heating. The LWECH probe is being developed for use with power settings up to 2W. The electrical heater will be used at the high end of the range, and laser-light power will be used low end of the wattage range. The system consists of two components: the heater probe and a control unit. The probe is inserted into the measuring cavity through an opening in the insulating baffle, and a sleeve is required to adapt to the measuring chamber. The probe is powered and controlled using electronics modules located separately. This paper will report on the design of the LWECH probe, initial tests, and expected performance

  14. Risk Factors and Predictive Model Development of Thirty-Day Post-Operative Surgical Site Infection in the Veterans Administration Surgical Population.

    Science.gov (United States)

    Li, Xinli; Nylander, William; Smith, Tracy; Han, Soonhee; Gunnar, William

    2018-04-01

    Surgical site infection (SSI) complicates approximately 2% of surgeries in the Veterans Affairs (VA) hospitals. Surgical site infections are responsible for increased morbidity, length of hospital stay, cost, and mortality. Surgical site infection can be minimized by modifying risk factors. In this study, we identified risk factors and developed accurate predictive surgical specialty-specific SSI risk prediction models for the Veterans Health Administration (VHA) surgery population. In a retrospective observation study, surgical patients who underwent surgery from October 2013 to September 2016 from 136 VA hospitals were included. The Veteran Affairs Surgical Quality Improvement Program (VASQIP) database was used for the pre-operative demographic and clinical characteristics, intra-operative characteristics, and 30-day post-operative outcomes. The study population represents 11 surgical specialties: neurosurgery, urology, podiatry, otolaryngology, general, orthopedic, plastic, thoracic, vascular, cardiac coronary artery bypass graft (CABG), and cardiac valve/other surgery. Multivariable logistic regression models were developed for the 30-day post-operative SSIs. Among 354,528 surgical procedures, 6,538 (1.8%) had SSIs within 30 days. Surgical site infection rates varied among surgical specialty (0.7%-3.0%). Surgical site infection rates were higher in emergency procedures, procedures with long operative duration, greater complexity, and higher relative value units. Other factors associated with increased SSI risk were high level of American Society of Anesthesiologists (ASA) classification (level 4 and 5), dyspnea, open wound/infection, wound classification, ascites, bleeding disorder, chemotherapy, smoking, history of severe chronic obstructive pulmonary disease (COPD), radiotherapy, steroid use for chronic conditions, and weight loss. Each surgical specialty had a distinct combination of risk factors. Accurate SSI risk-predictive surgery specialty

  15. Phosphorescent probes for two-photon microscopy of oxygen (Conference Presentation)

    Science.gov (United States)

    Vinogradov, Sergei A.; Esipova, Tatiana V.

    2016-03-01

    The ability to quantify oxygen in vivo in 3D with high spatial and temporal resolution is much needed in many areas of biological research. Our laboratory has been developing the phosphorescence quenching technique for biological oximetry - an optical method that possesses intrinsic microscopic capability. In the past we have developed dendritically protected oxygen probes for quantitative imaging of oxygen in tissue. More recently we expanded our design on special two-photon enhanced phosphorescent probes. These molecules brought about first demonstrations of the two-photon phosphorescence lifetime microscopy (2PLM) of oxygen in vivo, providing new information for neouroscience and stem cell biology. However, current two-photon oxygen probes suffer from a number of limitations, such as sub-optimal brightness and high cost of synthesis, which dramatically reduce imaging performance and limit usability of the method. In this paper we discuss principles of 2PLM and address the interplay between the probe chemistry, photophysics and spatial and temporal imaging resolution. We then present a new approach to brightly phosphorescent chromophores with internally enhanced two-photon absorption cross-sections, which pave a way to a new generation of 2PLM probes.

  16. [Surgical treatment of gynecomastia].

    Science.gov (United States)

    Târcoveanu, E; Lupaşcu, C; Vasilescu, A; Moldovanu, R; Ichim, Mihaela; Georgescu, St; Niculescu, D; Dănilă, N; Dimofte, G; Anton, Raluca; Crumpei, Felicia; Florea, Niculina; Ungureanu, Cristina

    2008-01-01

    Gynecomastia describes a benign increase of the mammary gland in men. When medical treatment fails, the surgical procedure is the treatment of choice. There are two main surgical procedures: subdermal mastectomy and liposuction. To evaluate the results after surgical treatment (mastectomy) performed in a general surgery unit. We performed a retrospective study; all the patients operated for gynecomastia were reviewed. The clinical, imaging, biological, intraoperative and histological data were included into a MS Access database and statistical analyzed. From 1990-2007, 114 patients were admitted in the First Surgical Clinic Iaşi for gynecomastia. Only 12.6% from the patients were with bilateral gynecomastia. The mean age was 40.54 +/- 1.83 years old (range 12-84). Mean body mass was 26.72 +/- 0.46 kg/m2 (range 18.5-41), and about 20% from the patients had a BMI of over 30 kg/m2. We also noted that 46.5% were smokers. Simon classification was used for preoperative staging: 2.6% from the cases (N = 3) were included in stage I, 16.7% (N = 19) in stage IIa, 50% (N = 57) in stage IIb and 30.7% in stage III. The patients included in stages IIa and I are younger then the patients included in stage III (p = 0.024). Mastodynia was noted in 46 cases (40.4%). Ultrasound exam was performed in all the cases, and the larger diameter of the nodule measured was 3.75 +/- 0.18 cm (range 0.5-9.7). Only three cases were preoperatively treated with tamoxifen. Most of the cases were operated using general anesthesia (53.5%). Mastectomy was performed by peri-areolar (70.2%), elliptical (28.9%) or radial (0.9%) incisions. The subdermal mastectomy using peri-areolar approach was performed especially for the cases included in stages I, IIa and IIb--p gynecomastia in 6 cases; the other cases presented dilated ducts. We also noted intraductal papillary hyperplasia in 87 cases and chronic inflammation in 35 cases. The histological exam also revealed intraductal papilloma--9 cases, fibro

  17. Ultrafast Dynamics of the VO2 Insulator-to-Metal Transition Observed by Nondegenerate Pump-Probe Spectroscopy

    Directory of Open Access Journals (Sweden)

    Haglund R. F.

    2013-03-01

    Full Text Available Non-degenerate pump (1.5 eV-probe (0.4 eV transmission spectroscopy on vanadium dioxide films grown on glass and three different sapphire substrates shows systematic variations with substrate that correlate with VO2 grain size and laser fluence. Temperature dependent measurements showed changes in the electronic response that is proportional to the metallic fraction.

  18. Diffusion probe for gas sampling in undisturbed soil

    DEFF Research Database (Denmark)

    Petersen, Søren O

    2014-01-01

    Soil-atmosphere fluxes of trace gases such as methane (CH4) and nitrous oxide (N2O) are determined by complex interactions between biological activity and soil conditions. Soil gas concentration profiles may, in combination with other information about soil conditions, help to understand emission...... controls. This note describes a simple and robust diffusion probe for soil gas sampling as part of flux monitoring programs. It can be deployed with minimum disturbance of in-situ conditions, also at sites with a high or fluctuating water table. Separate probes are used for each sampling depth...... on peat soils used for grazing showed soil gas concentrations of CH4 and N2O as influenced by topography, site conditions, and season. The applicability of the diffusion probe for trace gas monitoring is discussed....

  19. Field measuring probe for SSC [Superconducting Super Collider] magnets

    International Nuclear Information System (INIS)

    Ganetis, G.; Herrera, J.; Hogue, R.; Skaritka, J.; Wanderer, P.; Willen, E.

    1987-03-01

    The field probe developed for measuring the field in SSC dipole magnets is an adaptation of the rotating tangential coil system in use at Brookhaven for several years. Also known as the MOLE, it is a self-contained room-temperature mechanism that is pulled through the aperture of the magnet with regular stops to measure the local field. Several minutes are required to measure the field at each point. The probe measures the multipole components of the field as well as the field angle relative to gravity. The sensitivity of the coil and electronics is such that the field up to the full 6.6 T excitation of the magnet as well as the field when warm with only 0.01 T excitation can be measured. Tethers are attached to both ends of the probe to carry electrical connections and to supply dry nitrogen to the air motors that rotate the tangential windings as well as the gravity sensor. A small computer is attached to the probe for control and for data collection, analysis and storage. Digital voltmeters are used to digitize the voltages from the rotating coil and several custom circuits control motor speeds in the probe. The overall diameter of the probe is approximately 2 cm and its length is 2.4 m; the field sensitive windings are 0.6 m in length

  20. Endoscopic or surgical intervention for painful obstructive chronic pancreatitis.

    Science.gov (United States)

    Ahmed Ali, Usama; Pahlplatz, Johanna M; Nealon, Wiliam H; van Goor, Harry; Gooszen, Hein G; Boermeester, Marja A

    2015-03-19

    Endoscopy and surgery are the treatment modalities of choice for patients with chronic pancreatitis and dilated pancreatic duct (obstructive chronic pancreatitis). Physicians face, without clear consensus, the choice between endoscopy or surgery for this group of patients. To assess and compare the effects and complications of surgical and endoscopic interventions in the management of pain for obstructive chronic pancreatitis. We searched the following databases in The Cochrane Library: CENTRAL (2014, Issue 2), the Cochrane Database of Systematic Reviews (2014, Issue 2), and DARE (2014, Issue 2). We also searched the following databases up to 25 March 2014: MEDLINE (from 1950), Embase (from 1980), and the Conference Proceedings Citation Index - Science (CPCI-S) (from 1990). We performed a cross-reference search. Two review authors independently performed the selection of trials. All randomised controlled trials (RCTs) of endoscopic or surgical interventions in obstructive chronic pancreatitis. We included trials comparing endoscopic versus surgical interventions as well as trials comparing either endoscopic or surgical interventions to conservative treatment (i.e. non-invasive treatment modalities). We included relevant trials irrespective of blinding, the number of participants randomised, and the language of the article. We used standard methodological procedures expected by The Cochrane Collaboration. Two authors independently extracted data from the articles. We evaluated the methodological quality of the included trials and requested additional information from study authors in the case of missing data. We identified three eligible trials. Two trials compared endoscopic intervention with surgical intervention and included a total of 111 participants: 55 in the endoscopic group and 56 in the surgical group. Compared with the endoscopic group, the surgical group had a higher proportion of participants with pain relief, both at middle/long-term follow-up (two to

  1. Y2O3: Eu,Zn nanocrystals as a fluorescent probe for the detection of biotin

    International Nuclear Information System (INIS)

    Ganjkhanlou, Y.; Hosseinnia, A.; Kazemzad, M.; Khanlarkhani, A.; Moghaddam, A.B.

    2012-01-01

    We report on the application of nanocrystals (NCs) of the type Y 2 O 3 : Eu,Zn as a probe for the fluorescent detection of biotin in aqueous solution. The NCs were dispersed in water in the presence of various surface modifiers including mercaptoethanol (ME), monoethanolamine and ethylene glycol. Both the absorbance of surfactant and the stability of the suspensions were investigated in order to optimize the experimental conditions. ME is found to be the most suitable surfactant for stabilization of the suspended NCs. Their photoluminescence intensity is found to be quenched by biotin. The Stern-Volmer constant for the quenching process is 7.6 x 10 3 M -1 . This NC probe can be applied to the detection of biotin in the 1-60 μM concentration range with detection limit of 1.89 μM. The possible mechanisms of quenching also are discussed. (author)

  2. High-resolution photoelectron spectroscopy of TiO3H2-: Probing the TiO2- + H2O dissociative adduct

    Science.gov (United States)

    DeVine, Jessalyn A.; Abou Taka, Ali; Babin, Mark C.; Weichman, Marissa L.; Hratchian, Hrant P.; Neumark, Daniel M.

    2018-06-01

    Slow electron velocity-map imaging spectroscopy of cryogenically cooled TiO3H2- anions is used to probe the simplest titania/water reaction, TiO20/- + H2O. The resultant spectra show vibrationally resolved structure assigned to detachment from the cis-dihydroxide TiO(OH)2- geometry based on density functional theory calculations, demonstrating that for the reaction of the anionic TiO2- monomer with a single water molecule, the dissociative adduct (where the water is split) is energetically preferred over a molecularly adsorbed geometry. This work represents a significant improvement in resolution over previous measurements, yielding an electron affinity of 1.2529(4) eV as well as several vibrational frequencies for neutral TiO(OH)2. The energy resolution of the current results combined with photoelectron angular distributions reveals Herzberg-Teller coupling-induced transitions to Franck-Condon forbidden vibrational levels of the neutral ground state. A comparison to the previously measured spectrum of bare TiO2- indicates that reaction with water stabilizes neutral TiO2 more than the anion, providing insight into the fundamental chemical interactions between titania and water.

  3. NeuroMEMS: Neural Probe Microtechnologies

    Directory of Open Access Journals (Sweden)

    Sam Musallam

    2008-10-01

    Full Text Available Neural probe technologies have already had a significant positive effect on our understanding of the brain by revealing the functioning of networks of biological neurons. Probes are implanted in different areas of the brain to record and/or stimulate specific sites in the brain. Neural probes are currently used in many clinical settings for diagnosis of brain diseases such as seizers, epilepsy, migraine, Alzheimer’s, and dementia. We find these devices assisting paralyzed patients by allowing them to operate computers or robots using their neural activity. In recent years, probe technologies were assisted by rapid advancements in microfabrication and microelectronic technologies and thus are enabling highly functional and robust neural probes which are opening new and exciting avenues in neural sciences and brain machine interfaces. With a wide variety of probes that have been designed, fabricated, and tested to date, this review aims to provide an overview of the advances and recent progress in the microfabrication techniques of neural probes. In addition, we aim to highlight the challenges faced in developing and implementing ultralong multi-site recording probes that are needed to monitor neural activity from deeper regions in the brain. Finally, we review techniques that can improve the biocompatibility of the neural probes to minimize the immune response and encourage neural growth around the electrodes for long term implantation studies.

  4. Assessment of surgeon fatigue by surgical simulators

    Directory of Open Access Journals (Sweden)

    Tuwairqi K

    2015-04-01

    Full Text Available Khaled Tuwairqi,1 Jessica H Selter,2 Shameema Sikder3 1College of Medicine, University of Utah, Salt Lake City, UT, 2Johns Hopkins School of Medicine, 3Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA Background: The impact of fatigue on surgical performance and its implications for patient care is a growing concern. While investigators have employed a number of different tools to measure the effect of fatigue on surgical performance, the use of the surgical simulator has been increasingly implemented for this purpose. The goal of this paper is to review the published literature to achieve a better understanding of evaluation of fatigue on performance as studied with surgical simulators. Methods: A PubMed and Cochrane search was conducted using the search terms “simulator”, “surgery”, and “fatigue”. In total, 50 papers were evaluated, and 20 studies were selected after application of exclusion criteria. Articles were excluded if they did not use the simulator to assess the impact of fatigue on surgeon performance. Systematic reviews and case reports were also excluded. Results: Surgeon fatigue led to a consistent decline in cognitive function in six studies. Technical skills were evaluated in 18 studies, and a detrimental impact was reported in nine studies, while the remaining nine studies showed either no change or positive results with regard to surgical skills after experience of fatigue. Two pharmacological intervention studies reversed the detrimental impact of fatigue on cognitive function, but no change or a worsening effect was recognized for technical skills. Conclusion: Simulators are increasingly being used to evaluate the impact of fatigue on the surgeon's performance. With regard to the impact of fatigue in this regard, studies have demonstrated a consistent decline in cognitive function and mixed outcomes for technical skills. Larger studies that relate the simulator's results to real surgical

  5. Probing a gravitational cat state

    International Nuclear Information System (INIS)

    Anastopoulos, C; Hu, B L

    2015-01-01

    We investigate the nature of a gravitational two-state system (G2S) in the simplest setup in Newtonian gravity. In a quantum description of matter a single motionless massive particle can in principle be in a superposition state of two spatially separated locations. This superposition state in gravity, or gravitational cat state, would lead to fluctuations in the Newtonian force exerted on a nearby test particle. The central quantity of importance for this inquiry is the energy density correlation. This corresponds to the noise kernel in stochastic gravity theory, evaluated in the weak field nonrelativistic limit. In this limit quantum fluctuations of the stress–energy tensor manifest as the fluctuations of the Newtonian force. We describe the properties of such a G2S system and present two ways of measuring the cat state for the Newtonian force, one by way of a classical probe, the other a quantum harmonic oscillator. Our findings include: (i) mass density fluctuations persist even in single particle systems, and they are of the same order of magnitude as the mean; (ii) a classical probe generically records a non-Markovian fluctuating force; (iii) a quantum probe interacting with the G2S system may undergo Rabi oscillations in a strong coupling regime. This simple prototypical gravitational quantum system could provide a robust testing ground to compare predictions from alternative quantum theories, since the results reported here are based on standard quantum mechanics and classical gravity. (paper)

  6. R 2 inflation to probe non-perturbative quantum gravity

    Science.gov (United States)

    Koshelev, Alexey S.; Sravan Kumar, K.; Starobinsky, Alexei A.

    2018-03-01

    It is natural to expect a consistent inflationary model of the very early Universe to be an effective theory of quantum gravity, at least at energies much less than the Planck one. For the moment, R + R 2, or shortly R 2, inflation is the most successful in accounting for the latest CMB data from the PLANCK satellite and other experiments. Moreover, recently it was shown to be ultra-violet (UV) complete via an embedding into an analytic infinite derivative (AID) non-local gravity. In this paper, we derive a most general theory of gravity that contributes to perturbed linear equations of motion around maximally symmetric space-times. We show that such a theory is quadratic in the Ricci scalar and the Weyl tensor with AID operators along with the Einstein-Hilbert term and possibly a cosmological constant. We explicitly demonstrate that introduction of the Ricci tensor squared term is redundant. Working in this quadratic AID gravity framework without a cosmological term we prove that for a specified class of space homogeneous space-times, a space of solutions to the equations of motion is identical to the space of backgrounds in a local R 2 model. We further compute the full second order perturbed action around any background belonging to that class. We proceed by extracting the key inflationary parameters of our model such as a spectral index ( n s ), a tensor-to-scalar ratio ( r) and a tensor tilt ( n t ). It appears that n s remains the same as in the local R 2 inflation in the leading slow-roll approximation, while r and n t get modified due to modification of the tensor power spectrum. This class of models allows for any value of r complete R 2 gravity a natural target for future CMB probes.

  7. Comparison of postoperative surgical site infection after preoperative marking done with non-sterile stationary grade markers versus sterile surgical markers

    International Nuclear Information System (INIS)

    Mir, Z.A.

    2015-01-01

    Objectives: To compare the frequencies of post- operative surgical site infection after preoperative marking done with non-sterile stationary. grade markers versus sterile surgical markers in the same patient. Design: Randomized control trial. Place and Duration of Study: The department of Plastic surgery, Mayo hospital, Lahore from August 2013 to August 2014. Methods: This study was conducted after taking approval from the departmental ethical committee. Forty consecutive patients were included. A sterile surgical marker was used to mark one incision site while an alcohol based stationary grade marker was used to mark another incision site on the same patient. A standard preoperative, intraoperative and postoperative protocol was followed. Cultures were performed on swabs taken from the incision sites and surgical site infection was assessed for 30 days. Results: The study included 40 patients; 17 males and 23 females. The mean age of subjects was 25.32 ± 19.69 years with the minimum age being 2 years and the maximum being 63 years. No growth was seen in cultures taken from all the incision sites after skin preparation in the non sterile stationary grade marker group as well as the sterile surgical grade marker group. Also no surgical site infection appeared during the 30 day postoperative observation period in the non sterile stationary grade marker group as well as the sterile surgical grade marker group. (author)

  8. Prophylactic Antibiotic Choice and Risk of Surgical Site Infection After Hysterectomy.

    Science.gov (United States)

    Uppal, Shitanshu; Harris, John; Al-Niaimi, Ahmed; Swenson, Carolyn W; Pearlman, Mark D; Reynolds, R Kevin; Kamdar, Neil; Bazzi, Ali; Campbell, Darrell A; Morgan, Daniel M

    2016-02-01

    To evaluate associations between prophylactic preoperative antibiotic choice and surgical site infection rates after hysterectomy. A retrospective cohort study was performed of patients in the Michigan Surgical Quality Collaborative undergoing hysterectomy from July 2012 to February 2015. The primary outcome was a composite outcome of any surgical site infection (superficial surgical site infections or combined deep organ space surgical site infections). Preoperative antibiotics were categorized based on the recommendations set forth by the American College of Obstetricians and Gynecologists and the Surgical Care Improvement Project. Patients receiving a recommended antibiotic regimen were categorized into those receiving β-lactam antibiotics and those receiving alternatives to β-lactam antibiotics. Patients receiving nonrecommended antibiotics were categorized into those receiving overtreatment (excluded from further analysis) and those receiving nonstandard antibiotics. Multivariable logistic regression models were developed to estimate the independent effect of antibiotic choice. Propensity score matching analysis was performed to validate the results. The study included 21,358 hysterectomies. The overall rate of any surgical site infection was 2.06% (n=441). Unadjusted rates of "any surgical site infection" were 1.8%, 3.1%, and 3.7% for β-lactam, β-lactam alternatives, and nonstandard groups, respectively. After adjusting for patient and operative factors within clusters of hospitals, compared with the β-lactam antibiotics (reference group), the risk of "any surgical site infection" was higher for the group receiving β-lactam alternatives (odds ratio [OR] 1.7, confidence interval [CI] 1.27-2.07) or the nonstandard antibiotics (OR 2.0, CI 1.31-3.1). Compared with women receiving β-lactam antibiotic regimens, there is a higher risk of surgical site infection after hysterectomy among those receiving a recommended β-lactam alternative or nonstandard regimen.

  9. Probing into the Secret of the Chinese Air Force.

    Science.gov (United States)

    1983-11-30

    Ri35 968 PROBING INTO THE SECRET OF THE CHINESE AIR FOREE(IJ 1/2 FOREIGN TECHNOLOGY DIV WRIGHT-PATTERSON RFB OH 9 38 NOV 83 FTD-ID(,RS)T 1088 3...FOREIGN TECHNOLOGY DIVISION. PROBING INTO THE SECRET OF THE CHINESE AIRFORCE CL1 Approved for public re.lease; distribution unlimited C=)X ~ EET...MICROFICHE NR: FTD-83-C-001469 PROBING INTO THE SECRET OF THE CHINESE AIRFORCE -" -English pages: 111 Source: Enclosure to IR 6 842 0088 83-Booklet

  10. Postirradiation lesions of the brachial plexus. Results of surgical treatment

    International Nuclear Information System (INIS)

    LeQuang, C.

    1989-01-01

    In a series of 103 cases of postirradiation lesions of the brachial plexus operated on between 1978 and 1986--of which 60 patients have been reviewed with a follow up from 2 to 9 years--the surgical results are analyzed according to an anatomic classification, a clinical classification, and the surgical procedures. We conclude that the radiation plexitis should be treated surgically and at the earliest possible time after the onset of paresthesias. Also, the surgical procedure which gives the best results is neurolysis with pedicled omentoplasty

  11. Super-resolution imaging of a 2.5 kb non-repetitive DNA in situ in the nuclear genome using molecular beacon probes

    Science.gov (United States)

    Ni, Yanxiang; Cao, Bo; Ma, Tszshan; Niu, Gang; Huo, Yingdong; Huang, Jiandong; Chen, Danni; Liu, Yi; Yu, Bin; Zhang, Michael Q; Niu, Hanben

    2017-01-01

    High-resolution visualization of short non-repetitive DNA in situ in the nuclear genome is essential for studying looping interactions and chromatin organization in single cells. Recent advances in fluorescence in situ hybridization (FISH) using Oligopaint probes have enabled super-resolution imaging of genomic domains with a resolution limit of 4.9 kb. To target shorter elements, we developed a simple FISH method that uses molecular beacon (MB) probes to facilitate the probe-target binding, while minimizing non-specific fluorescence. We used three-dimensional stochastic optical reconstruction microscopy (3D-STORM) with optimized imaging conditions to efficiently distinguish sparsely distributed Alexa-647 from background cellular autofluorescence. Utilizing 3D-STORM and only 29–34 individual MB probes, we observed 3D fine-scale nanostructures of 2.5 kb integrated or endogenous unique DNA in situ in human or mouse genome, respectively. We demonstrated our MB-based FISH method was capable of visualizing the so far shortest non-repetitive genomic sequence in 3D at super-resolution. DOI: http://dx.doi.org/10.7554/eLife.21660.001 PMID:28485713

  12. A Fluorescent Probe for Sensitive Detection of Hydrazine and Its Application in Red Wine and Water.

    Science.gov (United States)

    Wang, Jialin; Wang, Hao; Yang, Shaoxiang; Tian, Hongyu; Liu, Yongguo; Hao, Yanfeng; Zhang, Jie; Sun, Baoguo

    2018-01-01

    A fluorescent probe, 7-(diethylamino)-2-oxo-2H-chromene-4-carbaldehyde (probe 1), was designed and synthesized for the sensitive detection of hydrazine. The addition of N 2 H 4 caused the fluorescence intensity of probe 1 to decrease. The probe's fluorescence was turn-off after adding N 2 H 4 , which could be observed under UV light at 365 nm. Moreover, once treated with different concentrations N 2 H 4 solutions, the solution color change could be distinguished, which indicates that probe 1 could be used as a visual sensor for hydrazine. Moreover, probe 1 can be used as a signal tool to determine hydrazine levels in solutions, such as red wine and water.

  13. Surgical competence.

    Science.gov (United States)

    Patil, Nivritti G; Cheng, Stephen W K; Wong, John

    2003-08-01

    Recent high-profile cases have heightened the need for a formal structure to monitor achievement and maintenance of surgical competence. Logbooks, morbidity and mortality meetings, videos and direct observation of operations using a checklist, motion analysis devices, and virtual reality simulators are effective tools for teaching and evaluating surgical skills. As the operating theater is also a place for training, there must be protocols and guidelines, including mandatory standards for supervision, to ensure that patient care is not compromised. Patients appreciate frank communication and honesty from surgeons regarding their expertise and level of competence. To ensure that surgical competence is maintained and keeps pace with technologic advances, professional registration bodies have been promoting programs for recertification. They evaluate performance in practice, professional standing, and commitment to ongoing education.

  14. Surgical Management of Recurrent Musculotendinous Hamstring Injury in Professional Athletes

    Science.gov (United States)

    Sonnery-Cottet, Bertrand; Daggett, Matt; Gardon, Roland; Pupim, Barbara; Clechet, Julien; Thaunat, Mathieu

    2015-01-01

    Background: Hamstring injury is the most common muscular lesion in athletes. The conservative treatment is well described, and surgical management is often indicated for proximal tendinous avulsions. To our knowledge, no surgical treatment has been proposed for failure of conservative treatment in musculotendinous hamstring lesions. Purpose: To describe the surgical management of proximal and distal hamstring musculotendinous junction lesions in professional athletes after failure of conservative treatment. Study Design: Case series; Level of evidence, 4. Methods: A consecutive series of 10 professional athletes, including 4 soccer players, 4 rugby players, and 2 handball players, underwent surgical intervention between October 2010 and June 2014 for the treatment of recurrent musculotendinous hamstring injuries. All athletes had failed at least 3 months of conservative treatment for a recurrent musculotendinous hamstring injury. Surgical resection of the musculotendinous scar tissue was performed using a longitudinal muscular suture. Lower Extremity Functional Scale (LEFS) and Marx scores were obtained at the 3-month follow-up, and a final phone interview was completed to determine recurrence of hamstring injury and return to previous level of play. Results: The mean age at surgery was 25.2 years (range, 19-35 years). The musculotendinous hamstring lesions involved 8 semitendinosus and 2 biceps femoris, with 6 injuries located proximally and 4 distally. Conservative treatment lasted a mean 5.1 months (range, 3-9 months) after last recurrence, and the patients had an average of 2.7 (range, 2-5) separate incidents of injury recurrence before surgical intervention was decided upon. At the 3-month follow-up, all patients had Marx activity scores of 16 and LEFS scores of 80. All 10 patients returned to the same level of play at a mean 3.4 months (range, 2-5 months). At a mean follow-up of 28.7 months, none of the athletes had suffered a recurrence. No surgical

  15. Evaluation of a flow direction probe and a pitot-static probe on the F-14 airplane at high angles of attack and sideslip

    Science.gov (United States)

    Larson, T. J.

    1984-01-01

    The measurement performance of a hemispherical flow-angularity probe and a fuselage-mounted pitot-static probe was evaluated at high flow angles as part of a test program on an F-14 airplane. These evaluations were performed using a calibrated pitot-static noseboom equipped with vanes for reference flow direction measurements, and another probe incorporating vanes but mounted on a pod under the fuselage nose. Data are presented for angles of attack up to 63, angles of sideslip from -22 deg to 22 deg, and for Mach numbers from approximately 0.3 to 1.3. During maneuvering flight, the hemispherical flow-angularity probe exhibited flow angle errors that exceeded 2 deg. Pressure measurements with the pitot-static probe resulted in very inaccurate data above a Mach number of 0.87 and exhibited large sensitivities with flow angle.

  16. SAGES TAVAC safety and effectiveness analysis: da Vinci ® Surgical System (Intuitive Surgical, Sunnyvale, CA).

    Science.gov (United States)

    Tsuda, Shawn; Oleynikov, Dmitry; Gould, Jon; Azagury, Dan; Sandler, Bryan; Hutter, Matthew; Ross, Sharona; Haas, Eric; Brody, Fred; Satava, Richard

    2015-10-01

    The da Vinci(®) Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) is a computer-assisted (robotic) surgical system designed to enable and enhance minimally invasive surgery. The Food and Drug Administration (FDA) has cleared computer-assisted surgical systems for use by trained physicians in an operating room environment for laparoscopic surgical procedures in general, cardiac, colorectal, gynecologic, head and neck, thoracic and urologic surgical procedures. There are substantial numbers of peer-reviewed papers regarding the da Vinci(®) Surgical System, and a thoughtful assessment of evidence framed by clinical opinion is warranted. The SAGES da Vinci(®) TAVAC sub-committee performed a literature review of the da Vinci(®) Surgical System regarding gastrointestinal surgery. Conclusions by the sub-committee were vetted by the SAGES TAVAC Committee and SAGES Executive Board. Following revisions, the document was evaluated by the TAVAC Committee and Executive Board again for final approval. Several conclusions were drawn based on expert opinion organized by safety, efficacy, and cost for robotic foregut, bariatric, hepatobiliary/pancreatic, colorectal surgery, and single-incision cholecystectomy. Gastrointestinal surgery with the da Vinci(®) Surgical System is safe and comparable, but not superior to standard laparoscopic approaches. Although clinically acceptable, its use may be costly for select gastrointestinal procedures. Current data are limited to the da Vinci(®) Surgical System; further analyses are needed.

  17. Detection of Fatigue Cracks at Rivets with Self-Nulling Probe

    Science.gov (United States)

    Wincheski, Buzz; Fulton, Jim; Nath, Shridhar; Namkung, Min

    1994-01-01

    A new eddy current probe developed at NASA Langley Research Center has been used to detect small cracks at rivets in aircraft lap splices [1]. The device has earlier been used to detect isolated fatigue cracks with a minimum detectable flaw size of roughly 1/2 to 1/3 the diameter of the probe [2]. The present work shows that the detectable flaw size for cracks originating at rivets can be greatly improved upon from that of isolated flaws. The use of a rotating probe method combined with spatial filtering has been used to detect 0.18 cm EDM notches, as measured from the rivet shank, with a 1.27 cm diameter probe and to detect flaws buried under the rivet head, down to a length of 0.076 cm, using a 0.32 cm diameter probe. The Self-Nulling Electromagnetic Flaw Detector induces a high density eddy current ring in the sample under test. A ferromagnetic flux focusing lens is incorporated such that in the absence of any inhomogeneities in the material under test only a minimal magnetic field will reach the interior of the probe. A magnetometer (pickup coil) located in the center of the probe therefore registers a null voltage in the absence of material defects. When a fatigue crack or other discontinuity is present in the test article the path of the eddy currents in the material is changed. The magnetic field associated with these eddy currents then enter into the interior of the probe, producing a large output voltage across the pickup coil leads. Further

  18. Impact of the Surgical Research Methodology Program on surgical residents' research profiles.

    Science.gov (United States)

    Farrokhyar, Forough; Amin, Nalin; Dath, Deepak; Bhandari, Mohit; Kelly, Stephan; Kolkin, Ann M; Gill-Pottruff, Catherine; Skot, Martina; Reid, Susan

    2014-01-01

    To evaluate whether implementing the formal Surgical Research Methodology (SRM) Program in the surgical residency curriculum improved research productivity compared with the preceding informal Research Seminar Series (RSS). The SRM Program replaced the RSS in July 2009. In the SRM Program, the curriculum in Year-1 consisted of 12 teaching sessions on the principles of clinical epidemiology and biostatistics, whereas the focus in Year-2 was on the design, conduct, and presentation of a research project. The RSS consisted of 8 research methodology sessions repeated annually for 2 years along with the design, conduct, and presentation of a research project. Research productivity was measured as the number of peer-reviewed publications and the generation of studies with higher levels of evidence. Outcome measures were independently assessed by 2 authors to avoid bias. Student t test and chi-square test were used for the analysis. Frequencies, mean differences with 95% CI, and effect sizes have been reported. In this study, 81 SRM residents were compared with 126 RSS residents. The performance of the SRM residents was superior on all metrics in our evaluation. They were significantly more productive and published more articles than the RSS residents (mean difference = 1.0 [95% CI: 0.5-1.5], p research performance improved 11.0 grades (95% CI: 8.5%-13.5%, p research methodology is crucial to appropriately apply evidence-based findings in clinical practice. The SRM Program has significantly improved the research productivity and performance of the surgical residents from all disciplines. The implementation of a similar research methodology program is highly recommended for the benefit of residents' future careers and ultimately, evidence-based patient care. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  19. University scientists test Mars probe equipment

    CERN Multimedia

    2002-01-01

    Scientists at Leicester University have spent four years researching and designing the Flight Model Position Adjustable Workbench (PAW) at the university. It will be attached to the Beagle 2 probe before being sent to the Red Planet in the spring (1/2 page).

  20. Preventing probe induced topography correlated artifacts in Kelvin Probe Force Microscopy

    NARCIS (Netherlands)

    Polak, L.; Wijngaarden, Rinke J.

    2016-01-01

    Kelvin Probe Force Microscopy (KPFM) on samples with rough surface topography can be hindered by topography correlated artifacts. We show that, with the proper experimental configuration and using homogeneously metal coated probes, we are able to obtain amplitude modulation (AM) KPFM results on a

  1. Surgical treatment of pancreatic pseudocysts – clinical experience

    Directory of Open Access Journals (Sweden)

    Artur Zakościelny

    2014-06-01

    Full Text Available Introduction: Pancreatic pseudocysts are frequent complications after acute and chronic pancreatitis. They are diagnosed in 6–18% of patients with the history of acute pancreatitis and in 20–40% cases with chronic pancreatitis. The aim of the study was to analyse early results of surgical treatment of pancreatic acute and chronic pseudocysts based on our experience. Material and methods: The retrospective analysis was based on early results of surgical treatment of 46 patients aged between 20 and 78 (33 males and 13 females who underwent treatment of acute (n = 26 and chronic (n = 20 pancreatic pseudocysts from November 2005 to July 2011 at the Second Department of General and Gastrointestinal Surgery and Surgical Oncology of the Alimentary Tract in Lublin. Results: The choice of a surgical method of treatment depended on the size, localisation, thickness of pseudocystic wall and changes in the main pancreatic duct. We used the following surgical methods: cystogastrostomy (Jurasz procedure was conducted in 22 patients (47.8%, Roux-en-Y cystojejunostomy was performed in 19 cases (41.3%, complete excision of the pseudocyst was possible in two patients (4.3% and cystoduodenostomy – in one case (2.1%. Also, in single cases external drainage (2.1% and cystopancreaticojejunostomy of Puestow (2.1% were applied. Forty-four patients (95.6% were cured. Early postoperative complications were observed in 2 patients (4.4%. Two reoperations (4.4% were required. Early postoperative mortality was 0%. Conclusions: Classic internal drainage procedures, known since the 19th century, are still effective methods of treatment in acute and chronic pancreatic pseudocysts.

  2. Design and fabrication of an actively cooled Langmuir probe for long pulse applications

    International Nuclear Information System (INIS)

    Paterson, J.A.; Biagi, L.A.; Ehlers, K.W.; Koehler, G.W.

    1985-11-01

    The details of the mechanical design and fabrication for a Langmuir Probe for the continuous monitoring of plasma density are given. The probe was designed for use as a diagnostic tool in the development of long pulse positive ion plasma sources for use on neutral beam systems. The essential design feature of this probe is the incorporation of two electrically isolated cooling water circuits which actively cool the probe tip and probe jacket. The electrical isolation is required to prevent drain currents from the probe body disturbing the measurement of the probe tip current and thereby the plasma density measurement. The successful realization of the design requires precision components and vacuum tight ceramic to refractory metal brazes. To date this design has successfully operated in steady-state in plasma densities up to 250 mA/cm 2 and surface heat fluxes of 25 W/cm 2

  3. Use of Performance Measures to Evaluate, Document Competence and Deterioration of Advanced Surgical Skills Exposure for Trauma (ASSET) Surgical Skills

    Science.gov (United States)

    2015-03-01

    Sharon Henry1, Stacy Shackelford4. 1Shock Trauma Anesthesiology Research, University of Maryland Baltimore; 2The Alfred Hospital and Swinburne...Bethesda USA, The Alfred Hospital and Swinburne University, Melbourne, Australia • 6) THE ASSETS OF ASSET: IMPROVING SURGICAL PERFROMANCE...ACTIVITY 820 CHANDLER STREET FORT DETRICK MD 21702-5014 January 15, 2015 SUBJECT: BA 150077- "Refreshing Combat Surgical Skills for Vascular Control

  4. Surgical site infection rates following laparoscopic urological procedures.

    Science.gov (United States)

    George, Arvin K; Srinivasan, Arun K; Cho, Jane; Sadek, Mostafa A; Kavoussi, Louis R

    2011-04-01

    Surgical site infections have been categorized by the Centers for Medicare and Medicaid Services as "never events". The incidence of surgical site infection following laparoscopic urological surgery and its risk factors are poorly defined. We evaluated surgical site infection following urological laparoscopic surgery and identified possible factors that may influence occurrence. Patients who underwent transperitoneal laparoscopic procedures during a 4-year period by a single laparoscopic surgeon were retrospectively reviewed. Surgical site infections were identified postoperatively and defined using the Centers for Disease Control criteria. Clinical parameters, comorbidities, smoking history, preoperative urinalysis and culture results as well as operative data were analyzed. Nonparametric testing using the Mann-Whitney U test, multivariable logistic regression and Spearman's rank correlation coefficient were used for data analysis. In 556 patients undergoing urological laparoscopic procedures 14 surgical site infections (2.5%) were identified at mean postoperative day 21.5. Of the 14 surgical site infections 10 (71.4%) were located at a specimen extraction site. Operative time, procedure type and increasing body mass index were significantly associated with the occurrence of surgical site infections (p = 0.007, p = 0.019, p = 0.038, respectively), whereas history of diabetes mellitus (p = 0.071) and intraoperative transfusion (p = 0.053) were found to trend toward significance. Age, gender, positive urine culture, steroid use, procedure type and smoking history were not significantly associated with surgical site infection. Body mass index and operative time remained significant predictors of surgical site infection on multivariate logistic regression analysis. Surgical site infection is an infrequent complication following laparoscopic surgery with the majority occurring at the specimen extraction site. Infection is associated with prolonged operative time and

  5. Heat Transfer Analysis and Modification of Thermal Probe for Gas-Solid Measurement

    Directory of Open Access Journals (Sweden)

    Hong Zhang

    2016-01-01

    Full Text Available The presented work aims to measure the gas-solid two-phase mass flow-rate in pneumatic conveyor, and a novel modified thermal probe is applied. A new analysis of the local heat transfer coefficients of thermal probe is presented, while traditional investigations focus on global coefficients. Thermal simulations are performed in Fluent 6.2 and temperature distributions of the probe are presented. The results indicate that the probe has obviously stable and unstable heat transfer areas. Based on understanding of probe characteristics, a modified probe structure is designed, which makes the probe output signal more stable and widens the measuring range. The experiments are carried out in a special designed laboratory scale pneumatic conveyor, and the modified probe shows an unambiguous improvement of the performance compared with the traditional one.

  6. Accuracy of micro four-point probe measurements on inhomogeneous samples: A probe spacing dependence study

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Østerberg, Frederik Westergaard

    2009-01-01

    In this paper, we discuss a probe spacing dependence study in order to estimate the accuracy of micro four-point probe measurements on inhomogeneous samples. Based on sensitivity calculations, both sheet resistance and Hall effect measurements are studied for samples (e.g. laser annealed samples...... the probe spacing is smaller than 1/40 of the variation wavelength, micro four-point probes can provide an accurate record of local properties with less than 1% measurement error. All the calculations agree well with previous experimental results.......) with periodic variations of sheet resistance, sheet carrier density, and carrier mobility. With a variation wavelength of ¿, probe spacings from 0.0012 to 1002 have been applied to characterize the local variations. The calculations show that the measurement error is highly dependent on the probe spacing. When...

  7. Synthesis and characterization of arylamine derivatives of rauwolscine as molecular probes for alpha 2-adrenergic receptors

    International Nuclear Information System (INIS)

    Lanier, S.M.; Graham, R.M.; Hess, H.J.; Grodski, A.; Repaske, M.G.; Nunnari, J.M.; Limbird, L.E.; Homcy, C.J.

    1987-01-01

    The selective alpha 2-adrenergic receptor antagonist rauwolscine was structurally modified to yield a series of arylamine carboxamide derivatives, which were investigated as potential molecular probes for the localization and structural characterization of alpha 2-adrenergic receptors. The arylamine carboxamides differ in the number of carbon atoms separating the reactive phenyl moiety from the fused ring structure of the parent compound, rauwolscine carboxylate. Competitive inhibition studies with [ 3 H]rauwolscine in rat kidney membranes indicate that the affinity for the carboxamide derivatives is inversely related to the length of the carbon spacer arm with rauwolscine 4-aminophenyl carboxamide exhibiting the highest affinity (Kd = 2.3 +/- 0.2 nM). Radioiodination of rau-AMPC yields a ligand, 125 I-rau-AMPC, which binds to rat kidney alpha 2-adrenergic receptors with high affinity, as determined by both kinetic analysis (Kd = k2/k1 = 0.016 min-1/2.1 X 10(7) M-1 min-1 = 0.76 nM) and equilibrium binding studies (Kd = 0.78 +/- 0.16 nM). 125 I-rau-AMPC was quantitatively converted to the photolabile arylazide derivative 17 alpha-hydroxy-20 alpha-yohimban-16 beta-(N-4-azido-3-[ 125 I]iodophenyl) carboxamide ( 125 I-rau-AZPC). In a partially purified receptor preparation from porcine brain, this compound photolabels a major (Mr = 62,000) peptide. The labeling of this peptide is inhibited by adrenergic agonists and antagonists with a rank order of potency consistent with an alpha 2-adrenergic receptor binding site. Both 125 I-rau-AMPC and the photolabile arylazide derivative, 125 I-rau-AZPC, should prove useful as molecular probes for the structural and biochemical characterization of alpha 2-adrenergic receptors

  8. Eddy-current probe design

    International Nuclear Information System (INIS)

    Kincaid, T.G.; McCary, R.O.

    1983-01-01

    This paper describes theoretical and experimental work directed toward finding the optimum probe dimensions and operating frequency for eddy current detection of half-penny surface cracks in nonmagnetic conducting materials. The study applies to probes which excite an approximately uniform spatial field over the length of the crack at the surface of the material. In practical terms, this means that the probe is not smaller than the crack length in any of its critical dimensions. The optimization of a simple coil probe is first analyzed in detail. It is shown that signal-to-noise ratio and lift-off discrimination are maximized by a pancake coil with mean radius not greater than the crack length, operated at a frequency which gives a skin depth equal to the crack depth. The results obtained for the simple coil are then used as a basis for discussion of the design of coils with ferrite cores and shields, and for the design of recording head type probes

  9. Fast reciprocating probe system on the EAST superconducting tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W.; Chang, J. F.; Wan, B. N.; Xu, G. S.; Li, B.; Xu, C. S.; Yan, N.; Wang, L.; Liu, S. C.; Jiang, M.; Liu, P. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Xiao, C. J. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Department of Physics and Engineering Physics, Plasma Physics Laboratory, University of Saskatchewan, Saskatoon SK S7N 5E2 (Canada)

    2010-11-15

    A new fast reciprocating probe system (FRPS) has been built and installed on the outer midplane of the EAST tokamak to investigate the profiles of the boundary plasma parameters such as electron density and temperature. The system consists of a two-stage motion drive mechanism: slow motion and fast motion. The fast motion is powered by a servo motor, which drives the probe horizontally up to 50 cm to scan the edge region of the EAST tokamak. The maximum velocity achieved is 2 m/s. High velocity and flexible control of the fast motion are the remarkable features of this FRPS. A specially designed connector installed at the front end of the probe shaft makes it easy to install or replace the probe head on FRPS. During the latest experimental campaign in the spring of 2010, a probe head with seven tips, including two tips for a Mach probe, has been used. An example is given for simultaneous profile measurements of the plasma temperature, plasma density, and the plasma flow velocity.

  10. Evaluation of diabetic foot osteomyelitis using probe to bone test and magnetic resonance imaging and their impact on surgical intervention

    Directory of Open Access Journals (Sweden)

    Fatma Zaiton

    2014-09-01

    Conclusion: PTB test is a simple, minimally invasive, low cost test and can be done at outpatient clinic. Its sensitivity and specificity are good when compared to those of MRI, but when we need to diagnose associated soft tissue infection and planning the surgical management MRI was the image of choice.

  11. Three-dimensional imaging of acetabular dysplasia: diagnostic value and impact on surgical type classification

    Energy Technology Data Exchange (ETDEWEB)

    Smet, Maria-Helena E-mail: marleen.smet@uz.kuleuven.ac.be; Marchal, Guy J.; Baert, Albert L.; Hoe, Lieven van; Cleynenbreugel, Johan van; Daniels, Hans; Molenaers, Guy; Moens, Pierre; Fabry, Guy

    2000-04-01

    Objective: To investigate the diagnostic value and the impact on surgical type classification of three-dimensional (3D) images for pre-surgical evaluation of dysplastic hips. Materials and methods: Three children with a different surgical type of hip dysplasia were investigated with helical computed tomography. For each patient, two-dimensional (2D) images, 3D, and a stereolithographic model of the dysplastic hip were generated. In two separate sessions, 40 medical observers independently analyzed the 2D images (session 1), the 2D and 3D images (session 2), and tried to identify the corresponding stereolithographic hip model. The influence of both image presentation (2D versus 3D images) and observer (degree of experience, radiologist versus orthopedic surgeon) were statistically analyzed. The SL model choice reflected the impact on surgical type classification. Results: Image presentation was a significant factor whereas the individual observer was not. Three-dimensional images scored significantly better than 2D images (P=0.0003). Three-dimensional imaging increased the correct surgical type classification by 35%. Conclusion: Three-dimensional images significantly improve the pre-surgical diagnostic assessment and surgical type classification of dysplastic hips.

  12. Three-dimensional imaging of acetabular dysplasia: diagnostic value and impact on surgical type classification

    International Nuclear Information System (INIS)

    Smet, Maria-Helena; Marchal, Guy J.; Baert, Albert L.; Hoe, Lieven van; Cleynenbreugel, Johan van; Daniels, Hans; Molenaers, Guy; Moens, Pierre; Fabry, Guy

    2000-01-01

    Objective: To investigate the diagnostic value and the impact on surgical type classification of three-dimensional (3D) images for pre-surgical evaluation of dysplastic hips. Materials and methods: Three children with a different surgical type of hip dysplasia were investigated with helical computed tomography. For each patient, two-dimensional (2D) images, 3D, and a stereolithographic model of the dysplastic hip were generated. In two separate sessions, 40 medical observers independently analyzed the 2D images (session 1), the 2D and 3D images (session 2), and tried to identify the corresponding stereolithographic hip model. The influence of both image presentation (2D versus 3D images) and observer (degree of experience, radiologist versus orthopedic surgeon) were statistically analyzed. The SL model choice reflected the impact on surgical type classification. Results: Image presentation was a significant factor whereas the individual observer was not. Three-dimensional images scored significantly better than 2D images (P=0.0003). Three-dimensional imaging increased the correct surgical type classification by 35%. Conclusion: Three-dimensional images significantly improve the pre-surgical diagnostic assessment and surgical type classification of dysplastic hips

  13. Wearable probes for service design

    DEFF Research Database (Denmark)

    Mullane, Aaron; Laaksolahti, Jarmo Matti; Svanæs, Dag

    2014-01-01

    Probes are used as a design method in user-centred design to allow end-users to inform design by collecting data from their lives. Probes are potentially useful in service innovation, but current probing methods require users to interrupt their activity and are consequently not ideal for use...... by service employees in reflecting on the delivery of a service. In this paper, we present the ‘wearable probe’, a probe concept that captures sensor data without distracting service employees. Data captured by the probe can be used by the service employees to reflect and co-reflect on the service journey......, helping to identify opportunities for service evolution and innovation....

  14. Recognizing surgical patterns

    NARCIS (Netherlands)

    Bouarfa, L.

    2012-01-01

    In the Netherlands, each year over 1700 patients die from preventable surgical errors. Numerous initiatives to improve surgical practice have had some impact, but problems persist. Despite the introduction of checklists and protocols, patient safety in surgery remains a continuing challenge. This is

  15. Aspheric surface measurement using capacitive probes

    Science.gov (United States)

    Tao, Xin; Yuan, Daocheng; Li, Shaobo

    2017-02-01

    With the application of aspheres in optical fields, high precision and high efficiency aspheric surface metrology becomes a hot research topic. We describe a novel method of non-contact measurement of aspheric surface with capacitive probe. Taking an eccentric spherical surface as the object of study, the averaging effect of capacitive probe measurement and the influence of tilting the capacitive probe on the measurement results are investigated. By comparing measurement results from simultaneous measurement of the capacitive probe and contact probe of roundness instrument, this paper indicates the feasibility of using capacitive probes to test aspheric surface and proposes the compensation method of measurement error caused by averaging effect and the tilting of the capacitive probe.

  16. Evaluation of lansoprazole as a probe for assessing cytochrome P450 2C19 activity and genotype-phenotype correlation in childhood.

    Science.gov (United States)

    Gumus, Ersin; Karaca, Ozgur; Babaoglu, Melih O; Baysoy, Gökhan; Balamtekin, Necati; Demir, Hulya; Uslu, Nuray; Bozkurt, Atilla; Yuce, Aysel; Yasar, Umit

    2012-05-01

    Lansoprazole, a cytochrome P450 2C19 (CYP2C19) substrate, has been widely used in children to manage acid-related diseases. CYP2C19 exhibits marked genetic polymorphisms, and distribution of these polymorphisms varies among different ethnic groups. There is limited data regarding the use of probe drugs for determining CYP2C19 activity in children. The aim of this study was to evaluate lansoprazole as an in vivo phenotyping probe for assessing CYP2C19 activity in children. The CYP2C19*2, *3, and *17 variants were determined in 244 children. Three hours after a single oral dose of lansoprazole (n = 94) or omeprazole (n = 19), plasma lansoprazole and 5-hydroxy lansoprazole or omeprazole and 5-hydroxy omeprazole concentrations were analyzed by high-performance liquid chromatography. The CYP2C19*17 was the most frequent variant allele (24.4%). The group of patients with CYP2C19*17*17 genotype had a 70% lower (p lansoprazole plasma concentration compared with the CYP2C19*1*1 genotype group, whereas the CYP2C19*2*2 group had 6.9-fold higher (p lansoprazole plasma concentration. Lansoprazole metabolic ratios (lansoprazole/5-hydroxy-lansoprazole) were found to be significantly lower in the *17*17 [mean ± standard deviation (SD); 2.8 ± 2.1] group and higher in the *2*2 group (63.5 ± 12.2) compared with that of the *1*1 genotype group (6.1 ± 4.5). According to our results from a Turkish pediatric population, lansoprazole is a suitable probe drug for phenotyping CYP2C19. The CYP2C19*2 and *17 variants should be taken into consideration in predicting the clinical outcome of therapy with lansoprazole in the pediatric population.

  17. Tumour reduction with a Cavitron Ultrasonic Surgical Aspirator® in ...

    African Journals Online (AJOL)

    of a scarf made the patient appear natural and presentable. Figure 1: The fungating tumour before tumour reduction with a Cavitron Ultrasonic Surgical Aspirator®. Tumour reduction with a Cavitron Ultrasonic. Surgical Aspirator® in the palliative care of anaplastic thyroid cancer. CASE REPORT. JHR Becker,1,2 F Ghoor1,2.

  18. Fluorescence spectral studies on interaction of fluorescent probes with Bovine Serum Albumin (BSA)

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Kaushik, E-mail: ghoshfcy@iitr.ac.in; Rathi, Sweety; Arora, Deepshikha

    2016-07-15

    Interaction of 2-(1-(naphthale-1-ylimino)ethyl)phenol (1), 2-methoxy-4-(((4-methoxyphenyl)imino)methyl)phenol (2) and 2-methoxy-4-((naphthalene-1-ylimino)methyl)phenol (3) with Bovine Serum Albumin (BSA) was examined. Fluorescence spectral data were obtained from the probes by varying the concentration of BSA as well as from BSA by varying the concentration of probes. Synchronous fluorescence measurements were performed and binding constants of the probes were calculated. To understand mode of quenching, Stern–Volmer plot, absorption spectral studies and life time measurements were performed. Förster resonance energy transfer (FRET) was also scrutinized. - Highlights: • Schiff bases with pendant phenolato function and interaction with BSA. • Synchronous fluorescence studies and a preferred interaction with tryptophan. • Probable interaction of probes with Trp-213 residue in the hydrophobic cavity. • 1:1 binding stoichiometry of probes and BSA in Benesi–Hildebrand graph.

  19. Selective and sensitive fluorescence-shift probes based on two dansyl groups for mercury(ii) ion detection.

    Science.gov (United States)

    Ma, Li-Jun; Liu, Jialun; Deng, Lefang; Zhao, Meili; Deng, Zhifu; Li, Xutian; Tang, Jian; Yang, Liting

    2014-11-01

    Two probes ( and ) bearing two dansyl fluorophores were synthesized and applied to the detection of mercury(ii) ions in aqueous solution. These probes exhibited a selective response to Hg(2+) in a buffered solution, with high sensitivity and a unique fluorescence response signal which displayed a blue-shift effect in the fluorescence emission peak. The Hg(2+) recognition mechanisms of the probes were determined by NMR spectroscopy, ESI-MS and UV-vis spectroscopy. The results showed that probe and mercury(ii) ions formed an unusual 2:2 stoichiometric ratio complex, while probe and Hg(2+) formed a multidentate complex with a stoichiometric ratio of 2:1.

  20. ORF Alignment: NC_002973 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available EKPASLICIAGGDTPLLTIEALIKANQTGEVDFSE 60 ... Query: 121 IDDRGGMDFXXXXXXXXXXXXFNEPFVPVDVNCHVVELDDVTKRVMSKYFDTDLPLT...HGI 180 ... IDDRGGMDF ... FNEPFVPVDVNCHVVELDDVTKRVMSKYFDTDLPLTHGI Sbjct: 121 IDDRGGMDFILLGIGLNGHIGFNEPFVPVDVNCHVVELDDVTKRVMSKYFDTDLPLTHGI 180 ...