WorldWideScience

Sample records for hg total pressure

  1. Structural and elastic properties of defect chalcopyrite HgGa{sub 2}S{sub 4} under high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Gomis, O., E-mail: osgohi@fis.upv.es [Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Santamaría-Pérez, D. [Departamento de Física Aplicada-ICMUV, MALTA Consolider Team, Universitat de València, Edificio de Investigación, C/Dr. Moliner 50, Burjassot, 46100 València (Spain); Departamento de Química Física I, Universidad Complutense de Madrid, MALTA Consolider Team, Avenida Complutense s/n, 28040 Madrid (Spain); Vilaplana, R.; Luna, R. [Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Sans, J.A.; Manjón, F.J. [Instituto de Diseño para la Fabricación y Producción Automatizada, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Errandonea, D. [Departamento de Física Aplicada-ICMUV, MALTA Consolider Team, Universitat de València, Edificio de Investigación, C/Dr. Moliner 50, Burjassot, 46100 València (Spain); and others

    2014-01-15

    Highlights: • Single crystals of HgGa{sub 2}S{sub 4} with defect-chalcopyrite (DC) structure were synthesized. • High-pressure X-ray diffraction in DC-HgGa{sub 2}S{sub 4} was performed. • Equation of state of DC-HgGa{sub 2}S{sub 4} determined (bulk modulus of 48.4 GPa). • Calculated elastic constants of DC-HgGa{sub 2}S{sub 4} reported at different pressures. • DC-HgGa{sub 2}S{sub 4} becomes mechanically unstable above 13.8 GPa. -- Abstract: In this work, we focus on the study of the structural and elastic properties of mercury digallium sulfide (HgGa{sub 2}S{sub 4}) at high pressures. This compound belongs to the family of AB{sub 2}X{sub 4} ordered-vacancy compounds and exhibits a tetragonal defect chalcopyrite structure. X-ray diffraction measurements at room temperature have been performed under compression up to 15.1 GPa in a diamond anvil cell. Our measurements have been complemented and compared with ab initio total energy calculations. The axial compressibility and the equation of state of the low-pressure phase of HgGa{sub 2}S{sub 4} have been experimentally and theoretically determined and compared to other related ordered-vacancy compounds. The pressure dependence of the theoretical cation–anion and vacancy-anion distances and compressibilities in HgGa{sub 2}S{sub 4} are reported and discussed in comparison to other related ordered-vacancy compounds. Finally, the pressure dependence of the theoretical elastic constants and elastic moduli of HgGa{sub 2}S{sub 4} has been studied. Our calculations indicate that the low-pressure phase of HgGa{sub 2}S{sub 4} becomes mechanically unstable above 13.8 GPa.

  2. Importance of Dissolved Neutral Hg-Sulfides, Energy Rich Organic Matter and total Hg Concentrations for Methyl Mercury Production in Sediments

    Science.gov (United States)

    Drott, A.; Skyllberg, U.

    2007-12-01

    Methyl mercury (MeHg) is the mercury form that biomagnifies to the greatest extent in aquatic food webs. Therefore information about factors determining MeHg concentrations is critical for accurate risk assessment of contaminated environments. The concentration of MeHg in wetlands and sediments is the net result of: 1) methylation rates, 2) demethylation rates, and 3) input/output processes. In this study, the main controls on Hg methylation rates and total concentrations of MeHg, were investigated at eight sites in Sweden with sediments that had been subjected to local Hg contamination either as Hg(0), or as phenyl-Hg. Sediments were selected to represent a gradient in total Hg concentration, temperature climate, salinity, primary productivity, and organic C content and quality. Most sediments were high in organic matter content due to wood fibre efflux from pulp and paper industry. The pore water was analysed for total Hg, MeHg, DOC, H2S(aq), pH, DOC, Cl and Br. The chemical speciation of Hg(II) and MeHg in pore water was calculated using equilibrium models. Potential methylation and demethylation rates in sediments were determined in incubation experiments at 23° C under N2(g) for 48 h, after addition of isotopically enriched 201Hg(II) and Me204Hg. In all surface (0-20 cm) sediments there was a significant (pdetermined specific potential methylation rate constant (Km, day-1) and % MeHg (concentrations of MeHg normalized to total Hg) in the sediment. This indicates that MeHg production overruled degradation and input/output processes of MeHg in surface sediments, and that % MeHg in surface sediments may be used as a proxy for net production of MeHg. To our knowledge, these are the first data showing significant positive relationships between short term (48 h) MeHg production and longer term accumulation of MeHg, across a range of sites with different properties (1). If MeHg was not normalized to total Hg, the relationship was not significant. For sub-sets of

  3. Incident Cardiovascular Disease Among Adults With Blood Pressure Hg.

    Science.gov (United States)

    Tajeu, Gabriel S; Booth, John N; Colantonio, Lisandro D; Gottesman, Rebecca F; Howard, George; Lackland, Daniel T; O'Brien, Emily C; Oparil, Suzanne; Ravenell, Joseph; Safford, Monika M; Seals, Samantha R; Shimbo, Daichi; Shea, Steven; Spruill, Tanya M; Tanner, Rikki M; Muntner, Paul

    2017-08-29

    Data from before the 2000s indicate that the majority of incident cardiovascular disease (CVD) events occur among US adults with systolic and diastolic blood pressure (SBP/DBP) ≥140/90 mm Hg. Over the past several decades, BP has declined and hypertension control has improved. We estimated the percentage of incident CVD events that occur at SBP/DBP Hg in a pooled analysis of 3 contemporary US cohorts: the REGARDS study (Reasons for Geographic and Racial Differences in Stroke), the MESA (Multi-Ethnic Study of Atherosclerosis), and the JHS (Jackson Heart Study) (n=31 856; REGARDS=21 208; MESA=6779; JHS=3869). Baseline study visits were conducted in 2003 to 2007 for REGARDS, 2000 to 2002 for MESA, and 2000 to 2004 for JHS. BP was measured by trained staff using standardized methods. Antihypertensive medication use was self-reported. The primary outcome was incident CVD, defined by the first occurrence of fatal or nonfatal stroke, nonfatal myocardial infarction, fatal coronary heart disease, or heart failure. Events were adjudicated in each study. Over a mean follow-up of 7.7 years, 2584 participants had incident CVD events. Overall, 63.0% (95% confidence interval [CI], 54.9-71.1) of events occurred in participants with SBP/DBP Hg; 58.4% (95% CI, 47.7-69.2) and 68.1% (95% CI, 60.1-76.0) among those taking and not taking antihypertensive medication, respectively. The majority of events occurred in participants with SBP/DBP Hg among those Hg, 76.6% (95% CI, 75.8-77.5) were eligible for statin treatment, but only 33.2% (95% CI, 32.1-34.3) were taking one, and 19.5% (95% CI, 18.5-20.5) met the SPRINT (Systolic Blood Pressure Intervention Trial) eligibility criteria and may benefit from a SBP target goal of 120 mm Hg. Although higher BP levels are associated with increased CVD risk, in the modern era, the majority of incident CVD events occur in US adults with SBP/DBP Hg. While absolute risk and cost-effectiveness should be considered, additional CVD risk

  4. Beer Law Constants and Vapor Pressures of HgI2 over HgI2(s,l)

    Science.gov (United States)

    Su, Ching-Hua; Zhu, Shen; Ramachandran, N.; Burger, A.

    2002-01-01

    Optical absorption spectra of the vapor phase over HgI2(s,l) were measured at sample temperatures between 349 and 610 K for wavelengths between 200 and 600 nm. The spectra show the samples sublimed congruently into HGI2 without any observed Hg or I2 absorption spectra. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were derived. From these constants the vapor pressure of HgI2, P, was found to be a function of temperature for the liquid and the solid beta-phases: ln P(atm) = -7700/T(K) + 12.462 (liquid phase) and ln P(atm) = -10150/T(K) + 17.026 (beta-phase). The expressions match the enthalpies of vaporization and sublimation of 15.30 and 20.17 kcal/mole respectively, for the liquid and the beta-phase HgI2. The difference in the enthalpies gives an enthalpy of fusion of 4.87 kcal/mole, and the intersection of the two expressions gives a melting point of 537 K.

  5. Thermodynamic properties of the liquid Hg-Tl alloys determined from vapour pressure measurements

    Directory of Open Access Journals (Sweden)

    Gierlotka W.

    2002-01-01

    Full Text Available The partial vapour pressure of mercury over liquid Hg-Tl liquid solutions were determined in the temperature range from 450 to 700 K by direct vapour pressure measurements carried out with the quartz gauge. From the measured ln pHg vs. T relationships activities of mercury were determined. Using Redlich-Kister formulas logarithms of the activity coefficients were described with the following equations: From which all thermodynamic functions in the solutions can be derived.

  6. Comparative analysis of pain in patients who underwent total knee replacement regarding the tourniquet pressure

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leão

    Full Text Available ABSTRACT OBJECTIVES: To evaluate through the visual analog scale (VAS the pain in patients undergoing total knee replacement (TKR with different pressures of the pneumatic tourniquet. METHODS: An observational, randomized, descriptive study on an analytical basis, with 60 patients who underwent TKR, divided into two groups, which were matched: a group where TKR was performed with tourniquet pressures of 350 mmHg (standard and the other with systolic blood pressure plus 100 mmHg (P + 100. These patients had their pain assessed by VAS at 48 h, and at the 5th and 15th days after procedure. Secondarily, the following were also measured: range of motion (ROM, complications, and blood drainage volume in each group; the data were subjected to statistical analysis. RESULTS: After data analysis, there was no statistical difference regarding the incidence of complications (p = 0.612, ROM (p = 0.202, bleeding after 24 and 48 h (p = 0.432 and p = 0.254 or in relation to VAS. No correlation was observed between time of ischemia compared to VAS and bleeding. CONCLUSIONS: The use of the pneumatic tourniquet pressure at 350 mmHg or systolic blood pressure plus 100 mmHg did not influence the pain, blood loss, ROM, and complications. Therefore the pressures at these levels are safe and do not change the surgery outcomes; the time of ischemia must be closely observed to avoid major complications.

  7. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    Science.gov (United States)

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  8. Helium Pressure Shift of the Hyperfine Clock Transition in Hg-201(+)

    Science.gov (United States)

    Larigani, S. Taghavi; Burt, E. A.; Tjoelker, R. L.

    2010-01-01

    There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave atomic clock: Hg-199(+) and Hg-201(+). We are investigating the viability of a trapped ion clock based on Hg-201(+) in a configuration that uses a buffer gas to increase ion loading efficiency and counter ion heating from rf trapping fields. Traditionally, either helium or neon is used as the buffer gas at approx. 10(exp -5) torr to confine mercury ions near room temperature. In addition to the buffer gas, other residual background gasses such as H2O, N2, O2, CO, CO2, and CH2 may be present in trace quantities. Collisions between trapped ions and buffer gas or background gas atoms/molecules produce a momentary shift of the ion clock transition frequency and constitute one of the largest systematic effects in this type of clock. Here we report an initial measurement of the He pressure shift in Hg-201(+) and compare this to Hg-199(+).

  9. Hg+ ion density in low-pressure Ar-Hg discharge plasma used for liquid crystal display back-lighting

    International Nuclear Information System (INIS)

    Goto, Miki; Arai, Toshihiko

    1995-01-01

    The positive column of a low-pressure Ar-Hg discharge has been applied as a fluorescent light source for illumination. Many studies on the diagnostics and fundamental mechanisms have been carried out on both the classical fluorescent lamp (d=36 mm) and the compact fluorescent lamp (d=12 mm). On the other hand, a lamp of extremely narrow diameter (usually below 6 mm) has been recently developed for liquid crystal display (LCD) back-lighting and its importance is undoubtedly increasing. Some characteristics or mechanisms of the narrow-diameter lamp may be similar to those of the 36 mm one; however the similarity rule does not hold between them due to the contributions from a stepwise ionization process. Therefore, in order to clarify the excitation mechanism in the narrow-diameter lamp quantitatively, various parameters must be measured directly and some analysis must be done. The Hg + ion density and electron density are important parameters for the purpose of clarifying the excitation mechanism quantitatively. In this work, we have measured the Hg + ion density using the modified absorption method, and the electron density using the probe method in the Ar-Hg discharge of the 4 mm bore tube on bath temperature. Moreover, with combining the modified absorption method and the probe method, the Hg 2 + molecular ion density has been determined

  10. A compare between myocardial topical negative pressure levels of -25 mmHg and -50 mmHg in a porcine model

    DEFF Research Database (Denmark)

    Lindstedt, Sandra; Paulsson, Per; Mokhtari, Arash

    2008-01-01

    Topical negative pressure (TNP), widely used in wound therapy, is known to stimulate wound edge blood flow, granulation tissue formation, angiogenesis, and revascularization. We have previously shown that application of a TNP of -50 mmHg to the myocardium significantly increases microvascular blo...

  11. 46 CFR 53.10-3 - Inspection and tests (modifies HG-500 through HG-540).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Inspection and tests (modifies HG-500 through HG-540... tests (modifies HG-500 through HG-540). (a) The inspections required by HG-500 through HG-540 must be performed by the “Authorized Inspector” as defined in HG-515 of section IV of the ASME Boiler and Pressure...

  12. Crystal structure of HgGa{sub 2}Se{sub 4} under compression

    Energy Technology Data Exchange (ETDEWEB)

    Gomis, Oscar, E-mail: osgohi@fis.upv.es [Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Vilaplana, Rosario [Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Manjón, Francisco Javier [Instituto de Diseño para la Fabricación y Producción Automatizada, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Santamaría-Pérez, David [Departamento de Química Física I, Universidad Complutense de Madrid, MALTA Consolider Team, Avenida Complutense s/n, 28040 Madrid (Spain); Departamento de Física Aplicada-ICMUV, MALTA Consolider Team, Universidad de Valencia, Edificio de Investigación, C/Dr. Moliner 50, Burjassot, 46100 Valencia (Spain); Errandonea, Daniel [Departamento de Física Aplicada-ICMUV, MALTA Consolider Team, Universidad de Valencia, Edificio de Investigación, C/Dr. Moliner 50, Burjassot, 46100 Valencia (Spain); and others

    2013-06-01

    Highlights: ► Single crystals of HgGa{sub 2}Se{sub 4} with defect-chalcopyrite structure were synthesized. ► HgGa{sub 2}Se{sub 4} exhibits a phase transition to a disordered rock salt structure at 17 GPa. ► HgGa{sub 2}Se{sub 4} undergoes a phase transition below 2.1 GPa to a disordered zinc blende. - Abstract: We report on high-pressure x-ray diffraction measurements up to 17.2 GPa in mercury digallium selenide (HgGa{sub 2}Se{sub 4}). The equation of state and the axial compressibilities for the low-pressure tetragonal phase have been determined and compared to related compounds. HgGa{sub 2}Se{sub 4} exhibits a phase transition on upstroke toward a disordered rock-salt structure beyond 17 GPa, while on downstroke it undergoes a phase transition below 2.1 GPa to a phase that could be assigned to a metastable zinc-blende structure with a total cation-vacancy disorder. Thermal annealing at low- and high-pressure shows that kinetics plays an important role on pressure-driven transitions.

  13. Ahmed Versus Baerveldt Glaucoma Drainage Implantation in Patients With Markedly Elevated Intraocular Pressure (≥30 mm Hg).

    Science.gov (United States)

    Resende, Arthur F; Moster, Marlene R; Patel, Neal S; Lee, Daniel; Dhami, Hermandeep; Pro, Michael J; Waisbourd, Michael

    2016-09-01

    Glaucoma patients with markedly elevated intraocular pressure (IOP) are at risk for developing severe hypotony-related complications. The goal of this study was to compare the surgical outcomes of the Ahmed Glaucoma Valve (AGV) and the Baerveldt Glaucoma Implant (BGI) in this patient population. Patients with preoperative IOP≥30 mm Hg were included. Outcome measures were: (1) surgical failure (IOP>21 mm Hg or glaucoma surgery, or loss of light perception) and (2) surgical complications. A total of 75 patients were included: 37 in the AGV group and 38 in the BGI group. The mean±SD follow-up was 2.3±1.6 years for the AGV group and 2.4±1.7 years for the BGI group (P=0.643). Mean preoperative IOP was 38.7±6.5 mm Hg for the AGV group and 40.8±7.6 mm Hg for the BGI group. At the last follow-up, 10 (27.0%) patients failed in the AGV group compared with 6 (15.8%) patients in the BGI group (P=0.379). The BGI group had higher rate of flat or shallow anterior chamber (n=4, 10%) compared with the AGV group (n=0, 0%) (P=0.043). Failure rates of AGV and BGI in patients with IOP≥30 mm Hg were comparable. There were more early hypotony-related complications in the BGI group; however, none were vision threatening. Both glaucoma drainage implants were effective in treating patients with uncontrolled glaucoma in an emergency setting.

  14. Global Burden of Hypertension and Systolic Blood Pressure of at Least 110 to 115 mm Hg, 1990-2015

    DEFF Research Database (Denmark)

    Forouzanfar, Mohammad H; Liu, Patrick; Roth, Gregory A

    2017-01-01

    Importance: Elevated systolic blood (SBP) pressure is a leading global health risk. Quantifying the levels of SBP is important to guide prevention policies and interventions. Objective: To estimate the association between SBP of at least 110 to 115 mm Hg and SBP of 140 mm Hg or higher and the bur......Importance: Elevated systolic blood (SBP) pressure is a leading global health risk. Quantifying the levels of SBP is important to guide prevention policies and interventions. Objective: To estimate the association between SBP of at least 110 to 115 mm Hg and SBP of 140 mm Hg or higher...... and the burden of different causes of death and disability by age and sex for 195 countries and territories, 1990-2015. Design: A comparative risk assessment of health loss related to SBP. Estimated distribution of SBP was based on 844 studies from 154 countries (published 1980-2015) of 8.69 million participants...... in the primary analysis. Main Outcomes and Measures: Mean SBP level, cause-specific deaths, and health burden related to SBP (≥110-115 mm Hg and also ≥140 mm Hg) by age, sex, country, and year. Results: Between 1990-2015, the rate of SBP of at least 110 to 115 mm Hg increased from 73 119 (95% uncertainty...

  15. Effect of Cooking on Speciation and In Vitro Bioaccessibility of Hg and As from Rice, Using Ordinary and Pressure Cookers.

    Science.gov (United States)

    Liao, Wen; Wang, Guang; Li, Kaiming; Zhao, Wenbo; Wu, Ye

    2018-05-03

    Rice is the most widely consumed staple food for a large part of the world's human population, and owing to environmental pollution, it is a major source of human exposure to mercury (Hg) and arsenic (As). We evaluated the impact of cooking on the speciation and bioaccessibility of Hg and As from rice in this study. Results show that the dominant Hg and As species in rice from Guangzhou market in China were their inorganic forms (iHg and iAs), respectively. The cooking process modified the levels of Hg and As. Average Hg and As bioaccessibility in raw rice was 69.74 and 80.32%, respectively. Hg bioaccessibility decreased to 46.22 and 42.37% for pressure- and ordinary-cooked rice, respectively. In contrast, As bioaccessibility remained unchanged except after cooking with a large amount of water. Protein denaturation and the amount of soluble and volatile forms determine the bioaccessibility of Hg and As in cooked rice by being released into the cooking water or into the air. From the bioaccessibility data, the average established daily intake (EDI) values of Hg and As from pressure-cooked rice for children and adults were 0.034 and 0.025 μg kg -1  day -1 (Hg), and 0.735 and 0.559 μg kg -1  day -1 (As), respectively. This study provides novel insights into Hg and As exposure due to rice cooking.

  16. Hydrostatic pressure dependence of the superconducting transition temperature of HgBa2CaCu2O6+δ and HgBa2Ca2Cu3O8+δ

    International Nuclear Information System (INIS)

    Klehe, A.K.; Schilling, J.S.

    1994-02-01

    The dependence of the superconducting transition temperature T c (P) on purely hydrostatic pressure to 0.9 GPa has been determined in ac susceptibility studies in a He-gas pressure system for optimally doped ceramic samples of HgBa 2 CaCu 2 O 6+δ and HgBa 2 Ca 2 Cu 3 O 8+δ with superconducting transitions at T c (0) ≅ 126.6 K and 133.9 K, respectively. T c increases reversibly under hydrostatic pressure at the rates, d T c /dP ≅ +1.80 ± 0.06 K/GPa and +1.71 ± 0.05 K/GPa, respectively. Within experimental error, these values are the same as found previously for optimally doped single-layered HgBa 2 CuO 4+δ , where d T c /dP ≅ +1.72 ± 0.05 K/GPa. Remarkably, the logarithmic volume derivative of T c is nearly identical for all three compounds, dln T c /dlnV ≅ -1.20 ± 0.05, even though the bulk modulus differs by more than 30%. This provides strong evidence that a common mechanism is responsible for the pressure dependence of the superconducting state in all three compounds

  17. Nutrient digestibility and growth in rainbow trout (Oncorhynchus mykiss) are impaired by short term exposure to moderate supersaturation in total gas pressure

    DEFF Research Database (Denmark)

    Skov, Peter Vilhelm; Pedersen, Lars-Flemming; Pedersen, Per Bovbjerg

    2013-01-01

    Excess levels of dissolved nitrogen gas (N2) may occur in recirculating aquaculture systems, as a result of aeration efforts, localized occurrences of denitrification, or from insufficient degassing of makeup water. If levels of dissolved N2 are sufficiently high, or if oxygen (O2) is also...... maintained at or above saturation, this leads to a supersaturation in total gas pressure (TGP). Depending on severity, total gas pressures above saturation may lead to gas bubble trauma, evident by visual inspection of the fish. Physiological effects of subclinical levels of TGP are not well known and have...... not been investigated for rainbow trout. The present study examined the effects of N2 supersaturation, with or without simultaneous excess TGP. Supersaturation with N2 (ΔP 22mmHg) without total gas supersaturation (ΔTGP −6mmHg) did not have any significant effects on feed intake, feed conversion or growth...

  18. 46 CFR 53.05-1 - Safety valve requirements for steam boilers (modifies HG-400 and HG-401).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Safety valve requirements for steam boilers (modifies HG-400 and HG-401). 53.05-1 Section 53.05-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... requirements for steam boilers (modifies HG-400 and HG-401). (a) The pressure relief valve requirements and the...

  19. Comparison of total Hg results in sediment samples from Rio Grande reservoir determine by NAA and CV AAS

    International Nuclear Information System (INIS)

    Franklin, Robson L.

    2011-01-01

    The Rio Grande reservoir is located in the Metropolitan area of Sao Paulo and it is used for recreation purposes and as source water for drinking water production. During the last decades has been detected mercury contamination in the sediments of this reservoir, mainly in the eastern part, near the main affluent of the reservoir, in the Rio Grande da Serra and Ribeirao Pires counties. In the present study bottom sediment samples were collected in four different sites into four sampling campaigns during the period of September 2008 to January 2010. The samples were dried at room temperature, ground and passed through a 2 mm sieve. Total Hg determination in the sediment samples was carried out by two different analytical techniques: neutron activation analysis (NAA) and cold vapor atomic absorption spectrometry (CV AAS). The methodology validation, in terms of precision and accuracy, was performed by reference materials, and presented a recovery of 83 to 108%. The total Hg results obtained by both analytical techniques ranged from 3 to 71 mg kg-1 and were considered similar by statistical analysis, even though NAA technique furnishes the total concentration while CV AAS using the 3015 digestion procedure characterizes only the bioavailable Hg. These results confirm that both analytical techniques were suitable to detect the Hg concentration levels in the Rio Grande sediments studied. The Hg levels in the sediment of the Rio Grande reservoir confirm the anthropogenic origin for this element in this ecosystem. (author)

  20. Chemical stabilization and high pressure synthesis of Ba-free Hg-based superconductors, (Hg,M)Sr{sub 2}Ca{sub n-1}Cu{sub n}O{sub y}(N=1{approximately}3)

    Energy Technology Data Exchange (ETDEWEB)

    Kishio, K. [Univ. of Tokyo (Japan)]|[Kyoto Univ. (Japan); Shimoyama, J.; Hahakura, S. [Univ. of Tokyo (Japan)] [and others

    1994-12-31

    A homologous series of new Hg-based HTSC compounds, (Hg,M)Sr{sub 2}Ca{sub n-1}Cu{sub n}O{sub y} with n=1 to 3, have been synthesized. The stabilization of the pure phases have been accomplished by chemical doping of third elements such as M=Cr, Mo and Re. While the Hg1201(n=1) phase was readily obtained in this way, it was necessary to simultaneously dope Y into the Ca site to stabilize the Hg1212(n=2) phase. On the other hand, single-phase Y-free Hg1212(n=2) and Hg1223(n=3) samples were synthesized only under a high pressure of 6 GPa. In sharp contrast to the Ba-containing compounds, all the samples prepared in the present study have been quite stable during the synthesis and no deterioration in air has been observed after the preparation.

  1. Methylation of Hg downstream from the Bonanza Hg mine, Oregon

    Science.gov (United States)

    Gray, John E.; Hines, Mark E.; Krabbenhoft, David P.; Thoms, Bryn

    2012-01-01

    Speciation of Hg and conversion to methyl-Hg were evaluated in stream sediment, stream water, and aquatic snails collected downstream from the Bonanza Hg mine, Oregon. Total production from the Bonanza mine was >1360t of Hg, during mining from the late 1800s to 1960, ranking it as an intermediate sized Hg mine on an international scale. The primary objective of this study was to evaluate the distribution, transport, and methylation of Hg downstream from a Hg mine in a coastal temperate climatic zone. Data shown here for methyl-Hg, a neurotoxin hazardous to humans, are the first reported for sediment and water from this area. Stream sediment collected from Foster Creek flowing downstream from the Bonanza mine contained elevated Hg concentrations that ranged from 590 to 71,000ng/g, all of which (except the most distal sample) exceeded the probable effect concentration (PEC) of 1060ng/g, the Hg concentration above which harmful effects are likely to be observed in sediment-dwelling organisms. Concentrations of methyl-Hg in stream sediment collected from Foster Creek varied from 11 to 62ng/g and were highly elevated compared to regional baseline concentrations (0.11-0.82ng/g) established in this study. Methyl-Hg concentrations in stream sediment collected in this study showed a significant correlation with total organic C (TOC, R2=0.62), generally indicating increased methyl-Hg formation with increasing TOC in sediment. Isotopic-tracer methods indicated that several samples of Foster Creek sediment exhibited high rates of Hg-methylation. Concentrations of Hg in water collected downstream from the mine varied from 17 to 270ng/L and were also elevated compared to baselines, but all were below the 770ng/L Hg standard recommended by the USEPA to protect against chronic effects to aquatic wildlife. Concentrations of methyl-Hg in the water collected from Foster Creek ranged from 0.17 to 1.8ng/L, which were elevated compared to regional baseline sites upstream and downstream

  2. Spatial-temporal dynamics and sources of total Hg in a hydroelectric reservoir in the Western Amazon, Brazil.

    Science.gov (United States)

    Pestana, I A; Bastos, W R; Almeida, M G; de Carvalho, D P; Rezende, C E; Souza, C M M

    2016-05-01

    Damming rivers to construct hydroelectric reservoirs results in a series of impacts on the biogeochemical Hg cycle. For example, modifying the hydrodynamics of a natural watercourse can result in the suspension and transport of Hg deposits in the water column, which represents an exposure risk for biota. The objective of this study was to evaluate the influences of seasonality on the dispersion of total Hg in the Hydroelectric Power Plant (HPP)-Samuel Reservoir (Porto Velho/Brazil). Sampling campaigns were performed during the three following hydrological periods characteristic of the region: low (Oct/2011), ebbing (May/2012), and high (Feb/2013) water. Sediment profiles, suspended particulate matter (SPM), and aquatic macrophytes (Eicchornia crassipes and Oryza spp.) were collected, and their Hg concentrations and isotopic and elemental C and N signatures were determined. The drainage basin significantly influenced the SPM compositions during all the periods, with a small autochthonous influence from the reservoir during the low water. The highest SPM Hg concentrations inside the reservoir were observed during the high water period, suggesting that the hydrodynamics of this environment favor the suspension of fine SPM, which has a higher Hg adsorption capacity. The Hg concentrations in the sediment profiles were ten times lower than those in the SPM, indicating that large particles with low Hg concentrations were deposited to form the bottom sediment. Hg concentrations were higher in aquatic macrophyte roots than in their leaves and appeared to contribute to the formation of SPM during the low water period. In this environment, Hg transport mainly occurs in SPM from the Jamari River drainage basin, which is the primary source of Hg in this environment.

  3. Determinants of systemic zero-flow arterial pressure.

    Science.gov (United States)

    Brunner, M J; Greene, A S; Sagawa, K; Shoukas, A A

    1983-09-01

    Thirteen pentobarbital-anesthetized dogs whose carotid sinuses were isolated and perfused at a constant pressure were placed on total cardiac bypass. With systemic venous pressure held at 0 mmHg (condition 1), arterial inflow was stopped for 20 s at intrasinus pressures of 50, 125, and 200 mmHg. Zero-flow arterial pressures under condition 1 were 16.2 +/- 1.3 (SE), 13.8 +/- 1.1, and 12.5 +/- 0.8 mmHg, respectively. In condition 2, the venous outflow tube was clamped at the instant of stopping the inflow, causing venous pressure to rise. The zero-flow arterial pressures were 19.7 +/- 1.3, 18.5 +/- 1.4, and 16.4 +/- 1.2 mmHg for intrasinus pressures of 50, 125, and 200 mmHg, respectively. At all levels of intrasinus pressure, the zero-flow arterial pressure in condition 2 was higher (P less than 0.005) than in condition 1. In seven dogs, at an intrasinus pressure of 125 mmHg, epinephrine increased the zero-flow arterial pressure by 3.0 mmHg, whereas hexamethonium and papaverine decreased the zero-flow arterial pressure by 2 mmHg. Reductions in the hematocrit from 52 to 11% resulted in statistically significant changes (P less than 0.01) in zero-flow arterial pressures. Thus zero-flow arterial pressure was found to be affected by changes in venous pressure, hematocrit, and vasomotor tone. The evidence does not support the literally interpreted concept of the vascular waterfall as the model for the finite arteriovenous pressure difference at zero flow.

  4. Neutron diffraction study of structural transformations in ternary systems of HgSe sub 1 sub - sub x S sub x mercury chalcogenides at high pressure

    CERN Document Server

    Voronin, V I; Berger, I F; Glazkov, V P; Kozlenko, D P; Savenko, B N; Tikhomirov, S V

    2001-01-01

    The structure of the ternary systems of the HgSe sub 1 sub - sub x S sub x mercury chalcogenides is studied at high pressures up to 35 kbar. It is established that by increase in the pressure in the HgSe sub 1 sub - sub x S sub x there takes place the transition from the sphalerite type cubic structure to the cinnabar type hexagonal structure, which is accompanied by the jump-like change in the elementary cell volume and interatomic distances. The parameters of the elementary cell and positional parameters of the Hg and Se/S for the hexagonal phase of high pressure are determined. The existence of the two-phase state in the area of the phase transformation is determined

  5. 46 CFR 53.05-3 - Materials (modifies HG-401.2).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Materials (modifies HG-401.2). 53.05-3 Section 53.05-3... Pressure Relieving Devices (Article 4) § 53.05-3 Materials (modifies HG-401.2). Materials for valves must be in accordance with HG-401.2 of section IV of the ASME Boiler and Pressure Vessel Code...

  6. Prediction study of structural, electronic and optical properties of XIn2S4 (X = Hg, Zn) thiospinels under pressure effect

    International Nuclear Information System (INIS)

    Yousaf, Masood; Inam, F.; Khenata, R.; Murtaza, G.; Isa, A.R.M.; Saeed, M.A.

    2014-01-01

    Highlights: • Pressure effect is employed for the first time on HgIn 2 S 4 and ZnIn 2 S 4 thiospinels. • A number of physical parameters are calculated and equations are developed. • FP-LAPW+lo method is coupled with different approximations (GGA+U and mBJ-GGA). • Relationships between pressure and parameters are in accordance with the theory. • Computed band gap values have good agreement with the experimental values. -- Abstract: First principle calculations are carried out to study the effect of pressure (up to 30 GPa) on physical properties of HgIn 2 S 4 and ZnIn 2 S 4 thiospinels. A number of structural, electronic and optical parameters are calculated, and equations are developed for their prediction at different pressures. Highly effective all electron FP-LAPW+lo method coupled with two different approximations (GGA+U and mBJ-GGA) provides very accurate results. All relationships developed between pressure and structural parameters are in full accordance with the established theory thus validating the approach used in the current study. Computed In–S bond length for ZnIn 2 S 4 matches closely with the experimental value. The band gap values of 0.920 eV (1.851 eV) and 1.68 eV (2.733 eV) are obtained with GGA+U (mBJ-GGA) at 0 GPa for HgIn 2 S 4 and ZnIn 2 S 4 , respectively. Additionally, we have calculated the optical properties, namely, the complex dielectric function, refractive index, extinction coefficient, reflectivity, optical conductivity, absorption coefficient and electron energy loss function under pressure effect for radiation up to 30.0 eV. The first critical point also known as optical’s absorption edge calculated with GGA+U (mBJ-GGA) appears at 0.939 eV (1.891 eV) and 1.701 eV (2.981 eV) for HgIn 2 S 4 and ZnIn 2 S 4 , respectively. Variation of the absorption spectrum indicates the prospective use of both compounds for device applications, which can be operated on a wide range of the energy scale. The entire work gives useful

  7. Relation between preoperative autonomic function and blood pressure change after tourniquet deflation during total knee replacement arthroplasty.

    Science.gov (United States)

    Huh, In Young; Kim, Dae-Young; Lee, Ji-Hyeon; Shin, Soo Jin; Cho, Young Woo; Park, Soon Eun

    2012-02-01

    Tourniquets are used to provide a bloodless surgical field for extremities. Hypotension due to vasodilation and bleeding after tourniquet deflation is a common event. Hemodynamic stability is modulated by the autonomic nervous system (ANS). Heart rate variability (HRV) is a sensitive method for detecting individuals who may be at risk of hemodynamic instability during general anesthesia. The purpose of this study was to investigate ANS function to predict hypotension after tourniquet deflation. Eighty-six patients who underwent total knee replacement arthroplasty (TKRA) were studied. HRV, systolic blood pressure variability (SBPV) and baroreflex sensitivity (BRS) were analyzed. We assigned two groups depending on the lowest systolic blood pressure (SBP) or mean BP (MBP) after tourniquet release (Group H; SBP 80 mmHg and MBP > 60 mmHg). Fifteen patients developed severe hypotension and ten patients were treated with ephedrine. Of the parameters of HRV, SBPV, and BRS, only BRS(SEQ) was significant being low in Group H. BRS and high-frequency SBPV were correlated with the degree of MBP change after tourniquet deflation. Preoperative low BRS is associated with hypotension after tourniquet deflation, suggesting the importance of baroreflex regulation for intraoperative hemodynamic stability.

  8. Global Burden of Hypertension and Systolic Blood Pressure of at Least 110 to 115 mm Hg, 1990-2015.

    Science.gov (United States)

    Forouzanfar, Mohammad H; Liu, Patrick; Roth, Gregory A; Ng, Marie; Biryukov, Stan; Marczak, Laurie; Alexander, Lily; Estep, Kara; Hassen Abate, Kalkidan; Akinyemiju, Tomi F; Ali, Raghib; Alvis-Guzman, Nelson; Azzopardi, Peter; Banerjee, Amitava; Bärnighausen, Till; Basu, Arindam; Bekele, Tolesa; Bennett, Derrick A; Biadgilign, Sibhatu; Catalá-López, Ferrán; Feigin, Valery L; Fernandes, Joao C; Fischer, Florian; Gebru, Alemseged Aregay; Gona, Philimon; Gupta, Rajeev; Hankey, Graeme J; Jonas, Jost B; Judd, Suzanne E; Khang, Young-Ho; Khosravi, Ardeshir; Kim, Yun Jin; Kimokoti, Ruth W; Kokubo, Yoshihiro; Kolte, Dhaval; Lopez, Alan; Lotufo, Paulo A; Malekzadeh, Reza; Melaku, Yohannes Adama; Mensah, George A; Misganaw, Awoke; Mokdad, Ali H; Moran, Andrew E; Nawaz, Haseeb; Neal, Bruce; Ngalesoni, Frida Namnyak; Ohkubo, Takayoshi; Pourmalek, Farshad; Rafay, Anwar; Rai, Rajesh Kumar; Rojas-Rueda, David; Sampson, Uchechukwu K; Santos, Itamar S; Sawhney, Monika; Schutte, Aletta E; Sepanlou, Sadaf G; Shifa, Girma Temam; Shiue, Ivy; Tedla, Bemnet Amare; Thrift, Amanda G; Tonelli, Marcello; Truelsen, Thomas; Tsilimparis, Nikolaos; Ukwaja, Kingsley Nnanna; Uthman, Olalekan A; Vasankari, Tommi; Venketasubramanian, Narayanaswamy; Vlassov, Vasiliy Victorovich; Vos, Theo; Westerman, Ronny; Yan, Lijing L; Yano, Yuichiro; Yonemoto, Naohiro; Zaki, Maysaa El Sayed; Murray, Christopher J L

    2017-01-10

    Elevated systolic blood (SBP) pressure is a leading global health risk. Quantifying the levels of SBP is important to guide prevention policies and interventions. To estimate the association between SBP of at least 110 to 115 mm Hg and SBP of 140 mm Hg or higher and the burden of different causes of death and disability by age and sex for 195 countries and territories, 1990-2015. A comparative risk assessment of health loss related to SBP. Estimated distribution of SBP was based on 844 studies from 154 countries (published 1980-2015) of 8.69 million participants. Spatiotemporal Gaussian process regression was used to generate estimates of mean SBP and adjusted variance for each age, sex, country, and year. Diseases with sufficient evidence for a causal relationship with high SBP (eg, ischemic heart disease, ischemic stroke, and hemorrhagic stroke) were included in the primary analysis. Mean SBP level, cause-specific deaths, and health burden related to SBP (≥110-115 mm Hg and also ≥140 mm Hg) by age, sex, country, and year. Between 1990-2015, the rate of SBP of at least 110 to 115 mm Hg increased from 73 119 (95% uncertainty interval [UI], 67 949-78 241) to 81 373 (95% UI, 76 814-85 770) per 100 000, and SBP of 140 mm Hg or higher increased from 17 307 (95% UI, 17 117-17 492) to 20 526 (95% UI, 20 283-20 746) per 100 000. The estimated annual death rate per 100 000 associated with SBP of at least 110 to 115 mm Hg increased from 135.6 (95% UI, 122.4-148.1) to 145.2 (95% UI 130.3-159.9) and the rate for SBP of 140 mm Hg or higher increased from 97.9 (95% UI, 87.5-108.1) to 106.3 (95% UI, 94.6-118.1). For loss of DALYs associated with systolic blood pressure of 140 mm Hg or higher, the loss increased from 95.9 million (95% uncertainty interval [UI], 87.0-104.9 million) to 143.0 million (95% UI, 130.2-157.0 million) [corrected], and for SBP of 140 mm Hg or higher, the loss increased from 5.2 million (95% UI, 4.6-5.7 million) to 7

  9. [Effects of pressure induced retinal ischemia on ERG in rabbit].

    Science.gov (United States)

    Song, G; Yang, X; Zhang, Z; Zhang, D

    2001-12-01

    To observe the effects of pressure induced retinal ischemia on electroretinogram(ERG) in rabbit. Retinal ischemia was induced in rabbits by increasing intraocular pressure at 30 mmHg, 60 mmHg, 90 mmHg, 120 mmHg for 45 minutes, and retinal function was monitored by eletroretinography. There was no difference on ERG before or after the experiment both in 30 mmHg group and control one. In 60 mmHg pressure induced ischemia eyes, the amplitudes of the b-wave and OPs wave reduced significantly. Four hours after reperfusion, they were totally recovered. After an ischemic insult of 90 mmHg or 120 mmHg for 45 minutes, there was no response of ERG. Four hours later, the amplitudes of the b-wave and OPs wave were 66.912 +/- 20.157 and 16.423 +/- 3.965 the former, 38.852 +/- 23.438 and 8.610 +/- 12.090 the latter, respectively. These results suggest that higher intraocular pressure causes more severe retina ischemic damage, and less recovery ability.

  10. Dorsalis pedis arterial pressure is lower than noninvasive arm blood pressure in normotensive patients under sevoflurane anesthesia.

    Science.gov (United States)

    Chen, Yan; Wang, Enqin; Zhu, Yuan; Li, Yongshuai; Lu, Kaizhi

    2016-02-01

    It is widely known that blood pressure (BP) in the lower extremity is higher than in the upper extremity. However, whether this phenomenon remains the same during general anesthesia is still unclear. This study aims to investigate the difference between invasive dorsalis pedis artery (DPA) pressure and the most commonly used noninvasive arm pressure during sevoflurane anesthesia. A total of 50 normotensive Chinese patients were enrolled in this observational study. Invasive DPA pressure, noninvasive arm pressure, and systemic vascular resistance index were assessed simultaneously. BP data during the entire surgery were analyzed through a Bland-Altman plot for repeated measures. The concordance of BP variation in the DPA and the arm was analyzed using four-quadrant plots and linear regression. The time-dependent changes in BP and the systemic vascular resistance index were also evaluated. Data from 46 effective cases were analyzed. Bias (95% limits of agreement) was -7.40 mmHg (-20.36 to +5.57 mmHg) for mean blood pressure, +3.54 mmHg (-20.32 to +27.41 mmHg) for systolic blood pressure, and -10.20 mmHg (-23.66 to +3.26 mmHg) for diastolic blood pressure, respectively. The concordance of BP variation at the two measurement sites was clinically acceptable. DPA pressure and vascular resistance in the lower limb decreased gradually during surgery. DPA pressure tends to be lower than arm pressure under sevoflurane anesthesia, especially the mean blood pressure and the diastolic blood pressure. Hence, noninvasive arm BP monitoring is recommend to be retained when invasive BP is measured at the DPA, so as to allow clinicians to comprehensively evaluate the BP condition of the patients and make appropriate therapeutic decisions.

  11. 46 CFR 53.01-5 - Scope (modifies HG-100).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Scope (modifies HG-100). 53.01-5 Section 53.01-5... General Requirements § 53.01-5 Scope (modifies HG-100). (a) The regulations in this part apply to steam... governing various types of pressure vessels and boilers. (b) Modifies HG-100. The requirements of Part HG of...

  12. Vapour pressure of components made by the presence of HgS(s,alpha) in an oil/gas reservoir and consequences for the produced gas

    Energy Technology Data Exchange (ETDEWEB)

    Oestvold, T.; Gustavsen, Oe.; Grande, K.; Aas, N.; Olsvik, Mimmi Kjetsaa

    2006-03-15

    A thermodynamic analysis is presented on how components made from HgS (s,alpha), existing in a oil/gas reservoir, will distribute themselves between gas, water, liquid and solid components as a function of temperature and pressure. The consequence of the formation of mercury containing components on gas injection and on gas quality is discussed. Since equilibrium is established in the model calculation, other gas components in the gas phase and components in condensed phases present will also influence the composition of the gas. Six cases are considered in the calculation: 1) HgS(s,alpha) - Ar(g), 2) HgS(s,alpha) - Ar (g) - water with 10-4 molal NaCl at pH = 7, 3) HgS(s,alpha) - CH{sub 4}(g), 4) HgS(s,alpha) - CH{sub 4} (g) - water with 10-4 molal NaCl at pH = 7 and 5) HgS(s,alpha) - natural gas - water with 10-4 molal NaCl at pH = 7, 6) HgS(s,alpha) - natural gas - water with 10-4 molal NaCl and 5*10-5 molal NO-3- at pH = 7. When HgS(s,alpha) is present in an oil reservoir at 170 deg C and 200 bar, these calculations show that the major components formed are: H{sub 2}(g), H{sub 2}S(g), Hg(l) and Hg(g) together with carbon. Mercury in the gas phase in the cases 1) is 4*10-7 bar and is determined by the evaporation and decomposition HgS(g) in the reservoir. In case 2) P{sub Hg} = 5.7*10-4 bar mainly determined by the formation of sulphate in the water phase. In the cases 3), 4) and 5) these calculations show that the major components formed are: H{sub 2}(g), H{sub 2}S(g), Hg(l) and Hg(g) together with carbon, and the gas phase is dominated by Hg(g) at approx. *10-3 bar. The water phase may contain Hg(CH{sub 3}NH{sub 2}){sub 2}2+ if NO{sub 3}- for some reasons is introduced into the formation water, and the very carcinogenic dimethyl mercury compound, C{sub 2}HgH{sub 6}, can be formed in the gas phase. Both compounds, however, in insignificant low concentration/partial pressure. (Author)

  13. A study of capillary discharge lamps in Ar-Hg and Xe-Hg mixtures

    International Nuclear Information System (INIS)

    Denisova, N; Gavare, Z; Revalde, G; Skudra, Ja; Veilande, R

    2011-01-01

    Low-pressure capillary discharge lamps in Ar-Hg and Xe-Hg mixtures are studied. The discharge size is 0.5 mm (500 μm) in radius. According to the literature, such types of plasma sources are classified as microplasmas. The studies include spectrally resolved optical measurements, tomographic reconstructions and numerical simulations using the collisional-radiative model for an Ar-Hg plasma. We discuss the problems of theoretical modelling and experimental diagnostics of microplasma sources. It is shown that the conventional collisional-radiative model, based on the assumption that transportation of atoms in the highly excited states can be neglected, has limitations in modelling a capillary discharge in an Ar-Hg mixture. It is found that diffusion of highly excited mercury atoms to the wall influences the emission properties of the capillary discharge. We have concluded that applications of the emission tomography method to microplasmas require a special analysis in each particular case.

  14. Annealing temperature and O2 partial pressure dependence of T(sub c) in HgBa2CuO(4+delta)

    Science.gov (United States)

    Xiong, Q.; Cao, Y.; Chen, F.; Xue, Y. Y.; Chu, C. W.

    1994-01-01

    Samples of HgBa2CuO(4+delta) (Hg-1201) were annealed under various conditions. After carefully controlling annealing time, annealing temperature (T(sub a)) and O2 partial pressure (P(sub 0)), we were able to find the reversible annealing conditions for Hg-1201. Under 1 atm O2 at 260 C less than or equal to T(sub a) less than or equal to 400 C, the obtained T(sub c) is nearly the same (approximately 97 K). However, it decreases quickly with T(sub a) greater than 300 C in high vacuum (P(sub 0) approximately 10(exp -8) atm), and reaches zero at T(sub a) = 400 C. On the other hand, T(sub c) decreases with the decrease of T(sub a) in high-pressure O2 (approximately 500 atm) and reaches approximately 20 K at about 240 C. In the entire annealing region, the oxygen surplus varies significantly from 0.03 to 0.4, and a wide range of T(sub c) variation (0 goes to 97 K goes to 20 K) was obtained with anion doping alone.

  15. Evaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting

    Directory of Open Access Journals (Sweden)

    Gonen Baser

    2016-12-01

    Full Text Available Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP, body weights, as well as systolic and diastolic blood pressures (SBP, DBP of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m. in the Ramadan of 2014 and two weeks after it. The data were analyzed using paired Student’s t-test and Pearson correlation analysis. Results: As the results demonstrated, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were 2.67±1.33 mmHg, 9.44±8.02 mmHg, 3.33±5.94 mmHg, and 0.90±0.46 kg during the fasting period, respectively. In addition, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were -0.33±1.4 mmHg (P=0.001, 0.55±7.25mmHg (P=0.003, -3.33±5.94 mmHg (P=0.001, and 0.12±0.45 kg (P=0.001 during the control period, respectively. There was a moderate correlation between the diurnal IOP and SBP differences (r=0.517, P=0.028. Conclusion: Based on the findings of the current study, the total fluid volume might have a more dominant effect on IOP peaks than the sympathetic system activity. Furthermore, the SBP was found to correlate with the IOP.

  16. Methyl mercury, but not inorganic mercury, associated with higher blood pressure during pregnancy.

    Science.gov (United States)

    Wells, Ellen M; Herbstman, Julie B; Lin, Yu Hong; Hibbeln, Joseph R; Halden, Rolf U; Witter, Frank R; Goldman, Lynn R

    2017-04-01

    Prior studies addressing associations between mercury and blood pressure have produced inconsistent findings; some of this may result from measuring total instead of speciated mercury. This cross-sectional study of 263 pregnant women assessed total mercury, speciated mercury, selenium, and n-3 polyunsaturated fatty acids in umbilical cord blood and blood pressure during labor and delivery. Models with a) total mercury or b) methyl and inorganic mercury were evaluated. Regression models adjusted for maternal age, race/ethnicity, prepregnancy body mass index, neighborhood income, parity, smoking, n-3 fatty acids and selenium. Geometric mean total, methyl, and inorganic mercury concentrations were 1.40µg/L (95% confidence interval: 1.29, 1.52); 0.95µg/L (0.84, 1.07); and 0.13µg/L (0.10, 0.17), respectively. Elevated systolic BP, diastolic BP, and pulse pressure were found, respectively, in 11.4%, 6.8%, and 19.8% of mothers. In adjusted multivariable models, a one-tertile increase of methyl mercury was associated with 2.83mmHg (0.17, 5.50) higher systolic blood pressure and 2.99mmHg (0.91, 5.08) higher pulse pressure. In the same models, an increase of one tertile of inorganic mercury was associated with -1.18mmHg (-3.72, 1.35) lower systolic blood pressure and -2.51mmHg (-4.49, -0.53) lower pulse pressure. No associations were observed with diastolic pressure. There was a non-significant trend of higher total mercury with higher systolic blood pressure. We observed a significant association of higher methyl mercury with higher systolic and pulse pressure, yet higher inorganic mercury was significantly associated with lower pulse pressure. These results should be confirmed with larger, longitudinal studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Measurement of intraocular pressure with pressure phosphene tonometry in children.

    Science.gov (United States)

    Fan, Dorothy S P; Chiu, Thomas Y H; Congdon, Nathan; Chan, Jeffrey C W; Cheung, Eva Y Y; Lam, Dennis S C

    2011-01-01

    To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children. Copyright 2011, SLACK Incorporated.

  18. A preliminary study of mercury exposure and blood pressure in the Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Guimarães Jean

    2006-10-01

    Full Text Available Abstract Background Fish is considered protective for coronary heart disease (CHD, but mercury (Hg intake from fish may counterbalance beneficial effects. Although neurotoxic effects of methylmercury (MeHg are well established, cardiovascular effects are still debated. The objective of the present study was to evaluate blood pressure in relation to Hg exposure and fish consumption among a non-indigenous fish-eating population in the Brazilian Amazon. Methods The study was conducted among 251 persons from six communities along the Tapajós River, a major tributary of the Amazon. Data was obtained for socio-demographic information, fish consumption, height and weight to determine body mass index (BMI, systolic and diastolic blood pressure, and Hg concentration in hair samples. Results Results showed that overall, systolic and diastolic blood pressure, were relatively low (mean: 113.9 mmHg ± 14.6 and 73.7 mmHg ± 11.0. Blood pressure was significantly associated with hair total Hg (H-Hg, age, BMI and gender. No association was observed between fish consumption and blood pressure, although there were significant inter-community differences. Logistic regression analyses showed that the Odds Ratio (OR for elevated systolic blood pressure (≥ 130 mmHg with H-Hg ≥ 10 μg/g was 2.91 [1.26–7.28], taking into account age, BMI, smoking, gender and community. Conclusion The findings of this preliminary study add further support for Hg cardiovascular toxicity.

  19. Lattice defects in semiconducting Hg/1-x/Cd/x/Te alloys. III - Defect structure of undoped Hg0.6Cd0.4Te

    Science.gov (United States)

    Vydyanath, H. R.; Donovan, J. D.; Nelson, D. A.

    1981-01-01

    Hall effect measurements were carried out on undoped Hg0.6Cd0.4Te crystals quenched to room temperature subsequent to equilibration at temperatures varying from 450 to 720 C under various partial pressures of Hg. The variation of the hole concentration as a function of the partial pressure of Hg indicates that the native acceptor defects are doubly ionized. Native donor defects are found to be negligible in concentration and the p-type to n-type conversion is shown to be due to residual donors and not due to native donor defects. Thermodynamic constant for the incorporation of the doubly ionized native acceptor defect has been established.

  20. Total flying hours and risk of high systolic blood pressure in the civilian pilot in Indonesia

    Directory of Open Access Journals (Sweden)

    Ferdi Afian

    2016-07-01

    Full Text Available Abstrak Latar belakang: Tekanan darah sistolik tinggi di antara pilot sipil antara lain akan menyebabkan gangguan kardiovaskular sehingga akan mengganggu kelancaran penerbangan. Tujuan penelitian ini ialah untuk mengetahui faktor-faktor dominan terhadap tekanan darah sistolik tinggi pada pilot sipil. Metode: Penelitian potong lintang dengan metode sampling purposif pada pilot yang melakukan pemeriksaan kesehatan berkala di Balai Kesehatan Penerbangan pada tanggal 18-29 Mei 2015. Data yang dikumpulkan adalah karakteristik demografi dan pekerjaan, klinis, kebiasaan olahraga, kebiasaan makan, indeks massa tubuh dan riwayat penyakit. Tekanan darah sistolik tinggi ialah tekanan darah sistolik140 mmHg atau lebih. Hasil: Dari 690 pilot yang melakukan pemeriksaan kesehatan berkala, 428 pilot laki-laki bersedia berpartisipasi mengikuti penelitian ini. Usia dan riwayat penyakit hipertensi merupakan faktor risiko dominan yang berhubungan dengan tekanan darah sistolik tinggi. Jika dibandingkan dengan pilot usia 19-39 tahun, yang berusia 40-65 tahun mempunyai 15,1 kali lipat lebih besar risiko terkena tekanan darah sistolik tinggi [rasio odds suaian (ORa= 15,12; p= 0,001]. Pilot dengan riwayat penyakit hipertensi dibandingkan dengan yang tidak ada riwayat memiliki risiko tekanan darah sistolik tinggi 93,2 kali lipat lebih besar (ORa= 93,21; p= 0,001 Kesimpulan: Usia 40-65 tahun dan memiliki riwayat hipertensi meningkatkan risiko tekanan darah sistolik tinggi di antara pilot sipil di Indonesia. Kata kunci: tekanan darah sistolik, total jam terbang, pilot sipil, Indonesia.  Abstract Background: Systolic high blood pressure among civilian pilots among others will cause cardiovascular disease and this condition will disrupt the flight.The purpose of this study was to identified the dominant factors related to high systolic blood pressure in the civilian pilots. Methods: A cross-sectional study with a purposive sampling method on a pilot who performed periodic

  1. Accuracy and precision of oscillometric blood pressure in standing conscious horses

    DEFF Research Database (Denmark)

    Olsen, Emil; Pedersen, Tilde Louise Skovgaard; Robinson, Rebecca

    2016-01-01

    from a teaching and research herd. HYPOTHESIS/OBJECTIVE: To evaluate the accuracy and precision of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and mean arterial pressure (MAP) in conscious horses obtained with an oscillometric NIBP device when compared to invasively measured...... administration. Agreement analysis with replicate measures was utilized to calculate bias (accuracy) and standard deviation (SD) of bias (precision). RESULTS: A total of 252 pairs of invasive arterial BP and NIBP measurements were analyzed. Compared to the direct BP measures, the NIBP MAP had an accuracy of -4...... mm Hg and precision of 10 mm Hg. SAP had an accuracy of -8 mm Hg and a precision of 17 mm Hg and DAP had an accuracy of -7 mm Hg and a precision of 14 mm Hg. CONCLUSIONS AND CLINICAL RELEVANCE: MAP from the evaluated NIBP monitor is accurate and precise in the adult horse across a range of BP...

  2. Evidence to Maintain the Systolic Blood Pressure Treatment Threshold at 140 mm Hg for Stroke Prevention: The Northern Manhattan Study.

    Science.gov (United States)

    Dong, Chuanhui; Della-Morte, David; Rundek, Tatjana; Wright, Clinton B; Elkind, Mitchell S V; Sacco, Ralph L

    2016-03-01

    In 2014, the Eighth Joint National Committee revised the target maximum systolic blood pressure (SBP) from 140 to 150 mm Hg in patients aged ≥60 years without diabetes mellitus or chronic kidney disease. The evidence from cohort studies supporting this change was sparse, particularly among US minority populations. In the Northern Manhattan Study, 1750 participants aged ≥60 years and free of stroke, diabetes mellitus, and chronic kidney disease had SBP measured at baseline and were annually followed up for incident stroke. Mean age at baseline was 72±8 years, 63% were women, 48% Hispanic, 25% non-Hispanic white, and 25% non-Hispanic black. Among all participants, 40% were on antihypertensive medications; 43% had SBP Hg, 20% had 140 to 149 mm Hg, and 37% had ≥150 mm Hg. Over a median follow-up of 13 years, 182 participants developed stroke. The crude stroke incidence was greater among individuals with SBP≥150 mm Hg (10.8 per 1000 person-years) and SBP 140 to 149 (12.3) than among those with SBPHg had an increased risk of stroke (hazard ratio, 1.7; 95% confidence interval, 1.2-2.6) compared with those with SBP Hg. The increased stroke risk was most notable among Hispanics and non-Hispanic blacks. Raising the SBP threshold from 140 to 150 mm Hg as a new target for hypertension treatment in older individuals without diabetes mellitus or chronic kidney disease could have a detrimental effect on stroke risk reduction, especially among minority US populations. © 2016 American Heart Association, Inc.

  3. Continuous positive airway pressure reduces blood pressure in patients with obstructive sleep apnea; a systematic review and meta-analysis with 1000 patients.

    Science.gov (United States)

    Schein, Andressa S O; Kerkhoff, Alessandra C; Coronel, Christian C; Plentz, Rodrigo D M; Sbruzzi, Graciele

    2014-09-01

    Obstructive sleep apnea (OSA) may lead to the development of hypertension and therapy with continuous positive airway pressure (CPAP) can promote reduction in blood pressure. The objective of this study is to review systematically the effects of CPAP on blood pressure in patients with OSA. The search was conducted in the following databases, from their beginning until February 2013: MEDLINE, Embase, Cochrane CENTRAL, Lilacs and PEDro. In addition, a manual search was performed on references of published studies. Randomized clinical trials (RCTs) that used CPAP compared with placebo CPAP or subtherapeutic CPAP for treatment of patients with OSA and that evaluated office SBP and DBP and 24-h ambulatory blood pressure were selected. Sixteen RCTs were included among 3409 publications, totaling 1166 patients. The use of CPAP resulted in reductions in office SBP [-3.20  mmHg; 95% confidence interval (CI) -4.67 to -1.72] and DBP (-2.87  mmHg; 95% CI -5.18 to -0.55); in night-time SBP (-4.92  mmHg; 95% CI -8.70 to -1.14); in mean 24-h blood pressure (-3.56  mmHg; 95% CI -6.79 to -0.33), mean night-time blood pressure (-2.56  mmHg; 95% CI -4.43 to -0.68) and 24-h DBP (-3.46  mmHg; 95% CI -6.75 to -0.17). However, no significant change was observed in daytime SBP (-0.74  mmHg; 95% CI -3.90 to 2.41) and daytime DBP (-1.86  mmHg; 95% CI -4.55 to 0.83). Treatment with CPAP promoted significantly but small reductions in blood pressure in individuals with OSA. Further studies should be performed to evaluate the effects of long-term CPAP and the impact on cardiovascular risk.

  4. Natural Hg isotopic composition of different Hg compounds in mammal tissues as a proxy for in vivo breakdown of toxic methylmercury.

    Science.gov (United States)

    Perrot, Vincent; Masbou, Jeremy; Pastukhov, Mikhail V; Epov, Vladimir N; Point, David; Bérail, Sylvain; Becker, Paul R; Sonke, Jeroen E; Amouroux, David

    2016-02-01

    In the last decade, specific attention has been paid to total mercury (HgT) stable isotopic composition, especially in natural samples such as aquatic organisms, due to its potential to track the cycle of this toxic element in the environment. Here, we investigated Hg Compound Specific stable Isotopic Composition (CSIC) of natural inorganic Hg (iHg) and methylmercury (MMHg) in various tissues of aquatic mammals (Beluga whale from the Arctic marine environment and seals from the freshwater lake Baikal, Russia). In seals' organs the variation in mass dependent fractionation (MDF, δ(202)Hg) for total Hg was significantly correlated to the respective fraction of iHg and MMHg compounds, with MMHg being enriched by ∼ 3‰ in heavier isotopes relative to iHg. On the other hand, we observe insignificant variation in Hg mass independent isotope fractionation (MIF, Δ(199)Hg) among iHg and MMHg in all organs for the same mammal species and MMHg in prey items. MIF signatures suggest that both MMHg and iHg in aquatic mammals have the same origin (i.e., MMHg from food), and are representative of Hg photochemistry in the water column of the mammal ecosystem. MDF signatures of Hg compounds indicate that MMHg is demethylated in vivo before being stored in the muscle, and the iHg formed is stored in the liver, and to a lesser extent in the kidney, before excretion. Thus, Hg CSIC analysis in mammals can be a powerful tool for tracing the metabolic response to Hg exposure.

  5. First report of 90-day support of 2 calves with a continuous-flow total artificial heart.

    Science.gov (United States)

    Karimov, Jamshid H; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A R; Fukamachi, Kiyotaka

    2015-09-01

    The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. CFTAH pumps have been implanted in 17 calves total. Hemodynamic parameters, pump performance, and device-related adverse events were evaluated during studies and at necropsy. In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure, 16 ± 3 mm Hg; right atrial pressure, 17 ± 3 mm Hg; right atrial pressure-left atrial pressure difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; and pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three animals with recent CFTAH implantation recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last 2 were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to human surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  6. Prediction study of structural, electronic and optical properties of XIn{sub 2}S{sub 4} (X = Hg, Zn) thiospinels under pressure effect

    Energy Technology Data Exchange (ETDEWEB)

    Yousaf, Masood [Physics Department, Faculty of Science, Universiti Teknologi Malaysia, Skudai 81310, Johor (Malaysia); Inam, F. [School of Science and Engineering, Lahore University of Management Sciences, Opposite Sector U, D.H.A. Lahore 54792 (Pakistan); Khenata, R. [Laboratoire de Physique Quantique et de Modélisation Mathématique (LPQ3M), Département de Technologie, Université de Mascara, 29000 Mascara (Algeria); Murtaza, G. [Department of Physics, Islamia College Peshawar, KPK (Pakistan); Isa, A.R.M. [Physics Department, Faculty of Science, Universiti Teknologi Malaysia, Skudai 81310, Johor (Malaysia); Saeed, M.A., E-mail: saeed@utm.my [Physics Department, Faculty of Science, Universiti Teknologi Malaysia, Skudai 81310, Johor (Malaysia)

    2014-03-15

    Highlights: • Pressure effect is employed for the first time on HgIn{sub 2}S{sub 4} and ZnIn{sub 2}S{sub 4} thiospinels. • A number of physical parameters are calculated and equations are developed. • FP-LAPW+lo method is coupled with different approximations (GGA+U and mBJ-GGA). • Relationships between pressure and parameters are in accordance with the theory. • Computed band gap values have good agreement with the experimental values. -- Abstract: First principle calculations are carried out to study the effect of pressure (up to 30 GPa) on physical properties of HgIn{sub 2}S{sub 4} and ZnIn{sub 2}S{sub 4} thiospinels. A number of structural, electronic and optical parameters are calculated, and equations are developed for their prediction at different pressures. Highly effective all electron FP-LAPW+lo method coupled with two different approximations (GGA+U and mBJ-GGA) provides very accurate results. All relationships developed between pressure and structural parameters are in full accordance with the established theory thus validating the approach used in the current study. Computed In–S bond length for ZnIn{sub 2}S{sub 4} matches closely with the experimental value. The band gap values of 0.920 eV (1.851 eV) and 1.68 eV (2.733 eV) are obtained with GGA+U (mBJ-GGA) at 0 GPa for HgIn{sub 2}S{sub 4} and ZnIn{sub 2}S{sub 4}, respectively. Additionally, we have calculated the optical properties, namely, the complex dielectric function, refractive index, extinction coefficient, reflectivity, optical conductivity, absorption coefficient and electron energy loss function under pressure effect for radiation up to 30.0 eV. The first critical point also known as optical’s absorption edge calculated with GGA+U (mBJ-GGA) appears at 0.939 eV (1.891 eV) and 1.701 eV (2.981 eV) for HgIn{sub 2}S{sub 4} and ZnIn{sub 2}S{sub 4}, respectively. Variation of the absorption spectrum indicates the prospective use of both compounds for device applications, which can be

  7. Hg uptake in ureteral obstructions

    International Nuclear Information System (INIS)

    Desgrez, J.P.; Bourguignon, M.; Raynaud, C.; CEA, 91 - Orsay

    1976-01-01

    In the presence of a total obstruction the results obtained with the Hg uptake test, as indeed with other functional tests, inform on the value of the kidney function at the time but have no prognostic value where repair possibilities are concerned. Some preliminary results seem to show however that very soon after the obstacle is removed, by the 10th or 15th day perhaps, quantitative functional tests may once more be used to evaluate the functional prognosis. This would mean that by waiting about two weeks after the disappearance of a total obstruction the Hg uptake test may again be used in all confidence. In order to check this deduction, which is based on slender evidence but which nevertheless has important practical implications, the measurement of the Hg uptake rate during the days following removal of the obstacle appears essential. In long-standing partial obstructions the Hg uptake rate gives an accurate assessment of the functional balance and helps considerably in the choice of therapy [fr

  8. Environmental contamination of mercury from Hg-mining areas in Wuchuan, northeastern Guizhou, China

    International Nuclear Information System (INIS)

    Qiu Guangle; Feng Xinbin; Wang Shaofeng; Shang Lihai

    2006-01-01

    Total Hg and methyl-Hg were evaluated in mine wastes, soils, water, and vegetations from the Wuchuan Hg-mining areas, Guizhou, China. Mine wastes contain high total Hg concentrations, ranging from 79 to 710 μg g -1 , and methyl-Hg from 0.32 to 3.9 ng g -1 . Total Hg in soil samples range from 0.33 to 320 μg g -1 and methyl-Hg from 0.69 to 20 ng g -1 . Vegetations present a high average total Hg concentration of 260 ng g -1 , which greatly exceeds the maximum Hg concentration of 20 ng g -1 recommended by the Chinese National Standard Agency for food sources. The rice samples contain elevated methyl-Hg concentrations, ranging from 4.2 to 18 ng g -1 . Stream water collected from Hg-mining areas is also contaminated, containing Hg as high as 360 ng l -1 , and methyl-Hg reaches up to 5.7 ng l -1 . Data indicate heavy Hg-contaminations and significant conversion of methyl-Hg in the study areas. - Mercury mining activities in Wuchun, Guizhou, China have resulted in seriously mercury contamination to the local environment

  9. Environmental contamination of mercury from Hg-mining areas in Wuchuan, northeastern Guizhou, China

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Guangle [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, 73 Guanshui Road, Guiyang, Guizhou 550002 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100039 (China); Feng Xinbin [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, 73 Guanshui Road, Guiyang, Guizhou 550002 (China)]. E-mail: fengxinbin@vip.skleg.cn; Wang Shaofeng [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, 73 Guanshui Road, Guiyang, Guizhou 550002 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100039 (China); Shang Lihai [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, 73 Guanshui Road, Guiyang, Guizhou 550002 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100039 (China)

    2006-08-15

    Total Hg and methyl-Hg were evaluated in mine wastes, soils, water, and vegetations from the Wuchuan Hg-mining areas, Guizhou, China. Mine wastes contain high total Hg concentrations, ranging from 79 to 710 {mu}g g{sup -1}, and methyl-Hg from 0.32 to 3.9 ng g{sup -1}. Total Hg in soil samples range from 0.33 to 320 {mu}g g{sup -1} and methyl-Hg from 0.69 to 20 ng g{sup -1}. Vegetations present a high average total Hg concentration of 260 ng g{sup -1}, which greatly exceeds the maximum Hg concentration of 20 ng g{sup -1} recommended by the Chinese National Standard Agency for food sources. The rice samples contain elevated methyl-Hg concentrations, ranging from 4.2 to 18 ng g{sup -1}. Stream water collected from Hg-mining areas is also contaminated, containing Hg as high as 360 ng l{sup -1}, and methyl-Hg reaches up to 5.7 ng l{sup -1}. Data indicate heavy Hg-contaminations and significant conversion of methyl-Hg in the study areas. - Mercury mining activities in Wuchun, Guizhou, China have resulted in seriously mercury contamination to the local environment.

  10. Total Site Heat Integration Considering Pressure Drops

    Directory of Open Access Journals (Sweden)

    Kew Hong Chew

    2015-02-01

    Full Text Available Pressure drop is an important consideration in Total Site Heat Integration (TSHI. This is due to the typically large distances between the different plants and the flow across plant elevations and equipment, including heat exchangers. Failure to consider pressure drop during utility targeting and heat exchanger network (HEN synthesis may, at best, lead to optimistic energy targets, and at worst, an inoperable system if the pumps or compressors cannot overcome the actual pressure drop. Most studies have addressed the pressure drop factor in terms of pumping cost, forbidden matches or allowable pressure drop constraints in the optimisation of HEN. This study looks at the implication of pressure drop in the context of a Total Site. The graphical Pinch-based TSHI methodology is extended to consider the pressure drop factor during the minimum energy requirement (MER targeting stage. The improved methodology provides a more realistic estimation of the MER targets and valuable insights for the implementation of the TSHI design. In the case study, when pressure drop in the steam distribution networks is considered, the heating and cooling duties increase by 14.5% and 4.5%.

  11. Blood Pressure Percentiles for School Children

    Directory of Open Access Journals (Sweden)

    İsmail Özanli

    2016-06-01

    Full Text Available Objective: The prevalence of hypertension in childhood and adolescence is gradually increasing. We aimed to in­vestigate the blood pressure (BP values of children aged 7-18 years. Methods: This study was conducted in a total of 3375 (1777 females, 1598 males children from 27 schools. Blood pressures of children were measured using sphyg­momanometer appropriate to arm circumference. Results: A positive relationship was found between sys­tolic blood pressure (SBP and diastolic blood pressure (DBP and the body weight, height, age and body mass index (BMI in male and female children. SBP was high­er in males than females after the age of 13. DBP was higher in males than the females after the age of 14. The mean annual increase of SBP was 2.06 mmHg in males and 1.54 mmHg in females. The mean annual increase of DBP was 1.52 mmHg in males and 1.38 mmHg in fe­males. Conclusion: In this study, we identified the threshold val­ues for blood pressure in children between the age of 7 and 18 years in Erzurum province. It is necessary to com­bine and evaluate data obtained from various regions for the identification of BP percentiles according to the age, gender and height percentiles of Turkish children.

  12. First Report of 90-Day Support of Two Calves with a Continuous-Flow Total Artificial Heart

    Science.gov (United States)

    Karimov, Jamshid H.; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A.; Fukamachi, Kiyotaka

    2015-01-01

    Objective The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. Methods CFTAH pumps have been implanted in 17 calves total. Hemodynamics, pump performance, and device-related adverse events were evaluated during studies and at necropsy. Results In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure [LAP], 16 ± 3 mm Hg; right atrial pressure [RAP], 17 ± 3 mm Hg; RAP-LAP difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three recent animals with the CFTAH recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last two were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. Conclusions The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. PMID:26173607

  13. HgSe(Te)-HgHal2 systems

    International Nuclear Information System (INIS)

    Pan'ko, V.V.; Khudolij, V.A.; Voroshilov, Yu.V.

    1989-01-01

    Using the methods of differential thermal and X-ray phase analyses the character of chemical interaction in the systems HgTe(Se)-HgHal 2 , where Hal is Cl, Br, I, is investigated. Formation of compounds Hg 3 Se 2 Hal 2 , Hg 3 Te 2 Hal 2 , Hg 3 TeCl 4 and Hg 3 TeBr 4 in these systems is established. The phase diagrams of the studied systems are presented. The parameters of elementary cells of the compounds with the unknown structure, as well as their unknown physicochemical properties, are determined

  14. Fluorescence emissions from mixtures of Hg with the noble gases

    International Nuclear Information System (INIS)

    Woodworth, J.R.

    1977-01-01

    Fluorescence emissions from mixtures of Hg with high pressure Xe, Kr, and Ar (approx.1 torr Hg, 10 3 --10 4 torr noble gas) have been studied using a short-pulse relativistic electron beam as an excitation source. Hg--noble gas molecular bands were observed on the red sides of the Hg lines (1849 and 2537 A) as well as on the red sides of the Hg visible lines (7 3 S 1 →6 3 P 0 , 1 , 2 ). Temporal histories and production efficiencies of the molecular emissions were determined and a model was formulated for the time histories of the HgXe 2600 A bands. Possible applications to high power laser systems are discussed

  15. Ruditapes philippinarum and Ruditapes decussatus under Hg environmental contamination.

    Science.gov (United States)

    Velez, Cátia; Galvão, Petrus; Longo, Renan; Malm, Olaf; Soares, Amadeu M V M; Figueira, Etelvina; Freitas, Rosa

    2015-08-01

    The native species Ruditapes decussatus and the invasive species Ruditapes philippinarum have an important ecological role and socio-economic value, from the Atlantic and Mediterranean to the Indo-Pacific region. In the aquatic environment, they are subjected to the presence of different contaminants, such as mercury (Hg) and its methylated form, methylmercury (MeHg). However, few studies have assessed the impacts of Hg on bivalves under environmental conditions, and little is known on bivalve oxidative stress patterns due to Hg contamination. Therefore, this study aims to assess the Hg contamination in sediments as well as the concentration of Hg and MeHg in R. decussatus and R. philippinarum, and to identify the detoxification strategies of both species living in sympatry, in an aquatic system with historical Hg contamination. The risk to human health due to the consumption of clams was also evaluated. The results obtained demonstrated that total Hg concentration found in sediments from the most contaminated area was higher than the maximum levels established by Sediment Quality Guidelines. This study further revealed that the total Hg and MeHg accumulation in both species was strongly correlated with the total Hg contamination of the sediments. Nonetheless, the THg concentration in both species was lower than maximum permissible limits (MPLs) of THg defined by international organizations. R. decussatus and R. philippinarum showed an increase in lipid peroxidation levels along with the increase of THg accumulation by clams. Nevertheless, for both species, no clear trend was obtained regarding the activity of antioxidant (superoxide dismutase, catalase) and biotransformation (glutathione S-transferase) enzymes and metallothioneins with the increase of THg in clams. Overall, the present work demonstrated that both species can be used as sentinel species of contamination and that the consumption of these clams does not constitute a risk for human health.

  16. A Soft Total Artificial Heart-First Concept Evaluation on a Hybrid Mock Circulation.

    Science.gov (United States)

    Cohrs, Nicholas H; Petrou, Anastasios; Loepfe, Michael; Yliruka, Maria; Schumacher, Christoph M; Kohll, A Xavier; Starck, Christoph T; Schmid Daners, Marianne; Meboldt, Mirko; Falk, Volkmar; Stark, Wendelin J

    2017-10-01

    The technology of 3D-printing has allowed the production of entirely soft pumps with complex chamber geometries. We used this technique to develop a completely soft pneumatically driven total artificial heart from silicone elastomers and evaluated its performance on a hybrid mock circulation. The goal of this study is to present an innovative concept of a soft total artificial heart (sTAH). Using the form of a human heart, we designed a sTAH, which consists of only two ventricles and produced it using a 3D-printing, lost-wax casting technique. The diastolic properties of the sTAH were defined and the performance of the sTAH was evaluated on a hybrid mock circulation under various physiological conditions. The sTAH achieved a blood flow of 2.2 L/min against a systemic vascular resistance of 1.11 mm Hg s/mL (afterload), when operated at 80 bpm. At the same time, the mean pulmonary venous pressure (preload) was fixed at 10 mm Hg. Furthermore, an aortic pulse pressure of 35 mm Hg was measured, with a mean aortic pressure of 48 mm Hg. The sTAH generated physiologically shaped signals of blood flow and pressures by mimicking the movement of a real heart. The preliminary results of this study show a promising potential of the soft pumps in heart replacements. Further work, focused on increasing blood flow and in turn aortic pressure is required. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. Perturbed angular correlations studies in the HgBa$_2$CaCu$_2$O$_{6+\\delta}$ high-T$_c$ superconductor

    CERN Document Server

    Mendonca, Tania Melo; Haas, Heinz; Odier, Philippe; Tavares, Pedro; SIlva, Manuel Ribeiro; Lopes, Armandina; Darie, Celine; Araujo, Joao Pedro

    2011-01-01

    The electric field gradients at $^{199m}$Hg nuclei have been measured via the perturbed angular correlation (PAC) technique, allowing a full characterization of the Hg neighborhood charge distribution at high oxygen doping on the Hg planes. The PAC technique has been applied to investigate the effect of high oxygen pressure during the measurement. Polycrystalline HgBa$_2$CaCu$_2$O$_{6+\\delta}$ (Hg-1212) samples have been annealed at 152 bar pressurized oxygen. The influence of oxygen pressure during the experiment was then investigated by measuring the samples at atmospheric pressure and under 152 bar oxygen pressure. The present set of PAC experiments shows that at high oxygen concentrations there is a non-uniform oxygen distribution. Moreover, the Hg environment is not free from oxygen and the results hint to a new type of ordering.

  18. 46 CFR 53.01-10 - Service restrictions and exceptions (replaces HG-101).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Service restrictions and exceptions (replaces HG-101... ENGINEERING HEATING BOILERS General Requirements § 53.01-10 Service restrictions and exceptions (replaces HG... lieu of the requirements in HG-101 of section IV of the ASME Boiler and Pressure Vessel Code...

  19. Sulfurization of Dissolved Organic Matter Increases Hg-Sulfide-Dissolved Organic Matter Bioavailability to a Hg-Methylating Bacterium.

    Science.gov (United States)

    Graham, Andrew M; Cameron-Burr, Keaton T; Hajic, Hayley A; Lee, Connie; Msekela, Deborah; Gilmour, Cynthia C

    2017-08-15

    Reactions of dissolved organic matter (DOM) with aqueous sulfide (termed sulfurization) in anoxic environments can substantially increase DOM's reduced sulfur functional group content. Sulfurization may affect DOM-trace metal interactions, including complexation and metal-containing particle precipitation, aggregation, and dissolution. Using a diverse suite of DOM samples, we found that susceptibility to additional sulfur incorporation via reaction with aqueous sulfide increased with increasing DOM aromatic-, carbonyl-, and carboxyl-C content. The role of DOM sulfurization in enhancing Hg bioavailability for microbial methylation was evaluated under conditions typical of Hg methylation environments (μM sulfide concentrations and low Hg-to-DOM molar ratios). Under the conditions of predicted metacinnabar supersaturation, microbial Hg methylation increased with increasing DOM sulfurization, likely reflecting either effective inhibition of metacinnabar growth and aggregation or the formation of Hg(II)-DOM thiol complexes with high bioavailability. Remarkably, Hg methylation efficiencies with the most sulfurized DOM samples were similar (>85% of total Hg methylated) to that observed in the presence of l-cysteine, a ligand facilitating rapid Hg(II) biouptake and methylation. This suggests that complexes of Hg(II) with DOM thiols have similar bioavailability to Hg(II) complexes with low-molecular-weight thiols. Overall, our results are a demonstration of the importance of DOM sulfurization to trace metal and metalloid (especially mercury) fate in the environment. DOM sulfurization likely represents another link between anthropogenic sulfate enrichment and MeHg production in the environment.

  20. Segmental blood pressure after total hip replacement

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Twenty-nine patients due to have a total hip replacement had their systemic systolic and segmental blood pressures measured prior to operation and 1 and 6 weeks postoperatively. No patients had signs of ischemia. The segmental blood pressure was measured at the ankle and at the toes. A significant...... drop was found in all pressures 1 week postoperatively. The decrease followed the systemic pressure and was restored to normal after 6 weeks. In a group of six patients with preoperatively decreased ankle pressure, a significant transient further decrease in the ankle-toe gradient pressure was found...... on the operated side. None of the patients had symptoms from the lowered pressure. We conclude that in patients without signs of ischemia, the postoperative segmental pressure decrease is reversible and therefore not dangerous....

  1. Study of the odd mass transition nuclei: 185Hg, 187Hg, 189Hg and 183Ir

    International Nuclear Information System (INIS)

    Zerrouki, A.

    1979-01-01

    The radioactive decay of 185 Tl, 186 Tl, 187 Tl has been studied on the isotope separator Isocele II working on line with the Orsay synchrocyclotron from Au( 3 He,xn) reactions: the emitted α lines have been measured and the main γ lines belonging to the 187 Tl→ 187 Hg decay have been identified. The 185 Hg, 187 Hg, 189 Hg high spin states have been studied using the following (HI,xn) reactions obtained on the Strasbourg MP Tandem: 168 Er( 24 Mg,xn) 187 Hg, 188 Hg, 166 Er( 24 Mg,xn) 185 Hg, 186 Hg, 157 Gd( 32 S,xn) 184 Hg, 185 Hg, 158 Gd( 32 S,5n) 185 Hg and 175 Lu( 19 F,5n) 189 Hg. The excitation functions are indicated and a high spin level scheme of 189 Hg is proposed: it is compared to the 'quasiparticle + triaxial rotor' model predictions. A level scheme of 183 Ir is proposed from the data collected at Isolde II (CERN) by Dr. SCHUCK: it is analysed within the framework of the same theoretical model used above [fr

  2. Hg Storage and Mobility in Tundra Soils of Northern Alaska

    Science.gov (United States)

    Olson, C.; Obrist, D.

    2017-12-01

    Atmospheric mercury (Hg) can be transported over long distances to remote regions such as the Arctic where it can then deposit and temporarily be stored in soils. This research aims to improve the understanding of terrestrial Hg storage and mobility in the arctic tundra, a large receptor area for atmospheric deposition and a major source of Hg to the Arctic Ocean. We aim to characterize spatial Hg pool sizes across various tundra sites and to quantify the mobility of Hg from thawing tundra soils using laboratory mobility experiments. Active layer and permafrost soil samples were collected in the summer of 2014 and 2015 at the Toolik Field Station in northern Alaska (68° 38' N) and along a 200 km transect extending from Toolik to the Arctic Ocean. Soil samples were analyzed for total Hg concentration, bulk density, and major and trace elements. Hg pool sizes were estimated by scaling up Hg soil concentrations using soil bulk density measurements. Mobility of Hg in tundra soils was quantified by shaking soil samples with ultrapure Milli-Q® water as an extracting solution for 24 and 72 hours. Additionally, meltwater samples were collected for analysis when present. The extracted supernatant was analyzed for total Hg, dissolved organic carbon, cations and anions, redox, and ph. Mobility of Hg from soil was calculated using Hg concentrations determined in solid soil samples and in supernatant of soil solution samples. Results of this study show Hg levels in tundra mineral soils that are 2-5 times higher than those observed at temperate sites closer to pollution sources. Most of the soil Hg was located in mineral horizons where Hg mass accounted for 72% of the total soil pool. Soil Hg pool sizes across the tundra sites were highly variable (166 - 1,365 g ha-1; avg. 419 g ha-1) due to the heterogeneity in soil type, bulk density, depth to frozen layer, and soil Hg concentration. Preliminary results from the laboratory experiment show higher mobility of Hg in mineral

  3. Valuation of Normal Range of Ankle Systolic Blood Pressure in Subjects with Normal Arm Systolic Blood Pressure.

    Science.gov (United States)

    Gong, Yi; Cao, Kai-wu; Xu, Jin-song; Li, Ju-xiang; Hong, Kui; Cheng, Xiao-shu; Su, Hai

    2015-01-01

    This study aimed to establish a normal range for ankle systolic blood pressure (SBP). A total of 948 subjects who had normal brachial SBP (90-139 mmHg) at investigation were enrolled. Supine BP of four limbs was simultaneously measured using four automatic BP measurement devices. The ankle-arm difference (An-a) on SBP of both sides was calculated. Two methods were used for establishing normal range of ankle SBP: the 99% method was decided on the 99% reference range of actual ankle BP, and the An-a method was the sum of An-a and the low or up limits of normal arm SBP (90-139 mmHg). Whether in the right or left side, the ankle SBP was significantly higher than the arm SBP (right: 137.1 ± 16.9 vs 119.7 ± 11.4 mmHg, P<0.05). Based on the 99% method, the normal range of ankle SBP was 94~181 mmHg for the total population, 84~166 mmHg for the young (18-44 y), 107~176 mmHg for the middle-aged(45-59 y) and 113~179 mmHg for the elderly (≥ 60 y) group. As the An-a on SBP was 13 mmHg in the young group and 20 mmHg in both middle-aged and elderly groups, the normal range of ankle SBP on the An-a method was 103-153 mmHg for young and 110-160 mmHg for middle-elderly subjects. A primary reference for normal ankle SBP was suggested as 100-165 mmHg in the young and 110-170 mmHg in the middle-elderly subjects.

  4. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  5. Impact of age on pulmonary artery systolic pressures at rest and with exercise

    Directory of Open Access Journals (Sweden)

    Garvan C Kane

    2016-06-01

    Full Text Available Aim: It is not well known if advancing age influences normal rest or exercise pulmonary artery pressures. The purpose of the study was to evaluate the association of increasing age with measurements of pulmonary artery systolic pressure at rest and with exercise. Subjects and methods: A total of 467 adults without cardiopulmonary disease and normal exercise capacity (age range: 18–85 years underwent symptom-limited treadmill exercise testing with Doppler measurement of rest and exercise pulmonary artery systolic pressure. Results: There was a progressive increase in rest and exercise pulmonary artery pressures with increasing age. Pulmonary artery systolic pressures at rest and with exercise were 25 ± 5 mmHg and 33 ± 9 mmHg, respectively, in those <40 years, and 30 ± 5 mmHg and 41 ± 12 mmHg, respectively, in those ≥70 years. While elevated left-sided cardiac filling pressures were excluded by protocol design, markers of arterial stiffness associated with the age-dependent effects on pulmonary pressures. Conclusion: These data demonstrate that in echocardiographically normal adults, pulmonary artery systolic pressure increases with advancing age. This increase is seen at rest and with exercise. These increases in pulmonary pressure occur in association with decreasing transpulmonary flow and increases in systemic pulse pressure, suggesting that age-associated blood vessel stiffening may contribute to these differences in pulmonary artery systolic pressure.

  6. Persistent Hg contamination and occurrence of Hg-methylating transcript (hgcA) downstream of a chlor-alkali plant in the Olt River (Romania).

    Science.gov (United States)

    Bravo, Andrea G; Loizeau, Jean-Luc; Dranguet, Perrine; Makri, Stamatina; Björn, Erik; Ungureanu, Viorel Gh; Slaveykova, Vera I; Cosio, Claudia

    2016-06-01

    Chlor-alkali plants using mercury (Hg) cell technology are acute point sources of Hg pollution in the aquatic environment. While there have been recent efforts to reduce the use of Hg cells, some of the emitted Hg can be transformed to neurotoxic methylmercury (MeHg). Here, we aimed (i) to study the dispersion of Hg in four reservoirs located downstream of a chlor-alkali plant along the Olt River (Romania) and (ii) to track the activity of bacterial functional genes involved in Hg methylation. Total Hg (THg) concentrations in water and sediments decreased successively from the initial reservoir to downstream reservoirs. Suspended fine size particles and seston appeared to be responsible for the transport of THg into downstream reservoirs, while macrophytes reflected the local bioavailability of Hg. The concentration and proportion of MeHg were correlated with THg, but were not correlated with bacterial activity in sediments, while the abundance of hgcA transcript correlated with organic matter and Cl(-) concentration, indicating the importance of Hg bioavailability in sediments for Hg methylation. Our data clearly highlights the importance of considering Hg contamination as a legacy pollutant since there is a high risk of continued Hg accumulation in food webs long after Hg-cell phase out.

  7. A preliminary study of the Hg flux from selected Ohio watersheds to Lake Erie

    International Nuclear Information System (INIS)

    Fitzgibbon, T.O.; Berry Lyons, W.; Gardner, Christopher B.; Carey, Anne E.

    2008-01-01

    New measurements of riverine dissolved and particulate Hg fluxes into Lake Erie from 12 northern Ohio watersheds have been determined from samples collected in April 2002 and analyzed using ultra-clean techniques with cold-vapor atomic fluorescence spectrometry. Total Hg concentrations ranged through 2.5-18.5 ng L -1 , with a mean of 10.4 ng L -1 with most Hg in particulate form. Dissolved Hg concentrations ranged through 0.8-4.3 ng L -1 , with a mean of 2.5 ng L -1 . Highest total Hg concentrations were observed in western rivers with primarily agricultural land use and eastern rivers with mixed land use in their watersheds. Total suspended solid concentrations ranged through 10-180 mg L -1 with particulate Hg concentrations ranging through 47-170 ng g -1 , with a mean of 99 ng g -1 . Particulate Hg was similar to published data for central Lake Erie bottom sediments but much lower than for bottom sediments in western Lake Erie. Total Hg concentrations were positively correlated with suspended sediment concentrations and negatively with dissolved NO 3 - concentrations. The total estimated annual Hg fluxes from these rivers into Lake Erie is estimated to be 85 kg, but because only one event was sampled during high flow conditions, this may be an overestimate. This is much lower than previous published estimates of riverine Hg input into Lake Erie

  8. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  9. Beryllium abundances in Hg-Mn stars

    International Nuclear Information System (INIS)

    Boesgaard, A.M.; Heacox, W.D.; Wolff, S.C.; Borsenberger, J.; Praderie, F.

    1982-01-01

    The Hg-Mn stars show anomalous line strengths of many chemical elements including Be. We have observed the Be ii resonance doublet at lambdalambda 3130, 3131 at 6.7 A mm -1 in 43 Hg-Mn stars and 10 normal stars in the same temperature range with the coude spectrograph of the 2.24 m University of Hawaii telescope at Mauna Kea. Measured equivalent widths of the two lines and/or the blend of the doublet have been compared with predictions from (1) LTE model atmospheres and (2) non-LTE line formation on non-LTE model atmospheres. (For strong Be ii lines, the LTE calculations result in more Be by factors of 2 to 4 than do the non-LTE calculations.) Overabundances of factors of 20--2 x 10 4 relative to solar have been found for 75% of the Hg-Mn stars. The 25% with little or no Be are typically among the cooler Hg-Mn stars, but for the stars with Be excesses, there is only marginal evidence for a correlationi of the size of the overabundance and temperature. It is suggested that diffusion driven by radiation pressure is responsible for the observed Be abundance anomalies

  10. Recovery of total Hg from geological matrices: a methodological intercomparison study (W6)

    International Nuclear Information System (INIS)

    Bloom, N.S.; Vondergeest, E.J.; Preus, E.M.; Horvat, M.; Prosenc, N.; Kingston, S.; Apte, S.; Pobbs, C.

    2002-01-01

    Full text: Aqua regia is commonly used for the extraction of Hg from soils prior to cold vapor spectrometry, but mass balance studies suggested it is not sufficiently robust to recover all Hg from more recalcitrant materials such as crystalline ores. As a result, an intercomparison exercise was undertaken between the following methods: (a) aqua regia digestion (EPA 7471) followed by SnCl 2 reduction, gold trapping and CVAFS detection, (b) Teflon bomb digestion at 110 o C with a 10:5:2 HNO 3 + HF + HCl mixture followed by SnCl 2 reduction, gold trapping and CVAFS, (c) 800 o C pyrolysis with gold trapping and CVAAS detection (EPA 7473), and (d) NAA followed by radiochemical separations using oxidative combustion and gold trapping. All methods gave quantitative recoveries from soil and sediment CRMs, but only the HF/HCI/HNO 3 digestion gave quantitative recoveries in all media. Pyrolysis resulted in approximately 88 ± 10 % recovery, while aqua regia digestion resulted in only about 61 ± 24 % recovery in bauxite ores and residues. RNAA generally gave the best agreement with the HF based digestion, although in a significant number of samples, particularly bauxite ores, recoveries were as low as 50 %. Based on these findings, we recommend that bomb digestions which include the use HF be applied to the analysis of Hg in geological solids, unless the matrix is documented to be fully extractable by a less rigorous procedure. We suggest a reference value for Hg in bauxite reference material (NIST-600) of 79.0 ± 2.0 ng/g, based on the pooled results of three laboratories. (author)

  11. Effect of total pressure on graphite oxidation

    International Nuclear Information System (INIS)

    Burnette, R.D.; Hoot, C.G.

    1983-04-01

    Graphite corrosion in the high-temperature gas-cooled reactor (HTGR) is calculated using two key assumptions: (1) the kinetic, catalysis, and transport characteristics of graphite determined by bench-scale tests apply to large components at reactor conditions and (2) the effects of high pressure and turbulent flow are predictable. To better understand the differences between laboratory tests and reactor conditions, a high-pressure test loop (HPTL) has been constructed and used to perform tests at reactor temperature, pressure, and flow conditions. The HPTL is intended to determine the functional dependence of oxidation rate and characteristics on total pressure and gas velocity and to compare the oxidation results with calculations using models and codes developed for the reactor

  12. Definition of ambulatory blood pressure targets for diagnosis and treatment of hypertension in relation to clinic blood pressure: prospective cohort study.

    Science.gov (United States)

    Head, Geoffrey A; Mihailidou, Anastasia S; Duggan, Karen A; Beilin, Lawrence J; Berry, Narelle; Brown, Mark A; Bune, Alex J; Cowley, Diane; Chalmers, John P; Howe, Peter R C; Hodgson, Jonathan; Ludbrook, John; Mangoni, Arduino A; McGrath, Barry P; Nelson, Mark R; Sharman, James E; Stowasser, Michael

    2010-04-14

    Twenty-four hour ambulatory blood pressure thresholds have been defined for the diagnosis of mild hypertension but not for its treatment or for other blood pressure thresholds used in the diagnosis of moderate to severe hypertension. We aimed to derive age and sex related ambulatory blood pressure equivalents to clinic blood pressure thresholds for diagnosis and treatment of hypertension. We collated 24 hour ambulatory blood pressure data, recorded with validated devices, from 11 centres across six Australian states (n=8575). We used least product regression to assess the relation between these measurements and clinic blood pressure measured by trained staff and in a smaller cohort by doctors (n=1693). Mean age of participants was 56 years (SD 15) with mean body mass index 28.9 (5.5) and mean clinic systolic/diastolic blood pressure 142/82 mm Hg (19/12); 4626 (54%) were women. Average clinic measurements by trained staff were 6/3 mm Hg higher than daytime ambulatory blood pressure and 10/5 mm Hg higher than 24 hour blood pressure, but 9/7 mm Hg lower than clinic values measured by doctors. Daytime ambulatory equivalents derived from trained staff clinic measurements were 4/3 mm Hg less than the 140/90 mm Hg clinic threshold (lower limit of grade 1 hypertension), 2/2 mm Hg less than the 130/80 mm Hg threshold (target upper limit for patients with associated conditions), and 1/1 mm Hg less than the 125/75 mm Hg threshold. Equivalents were 1/2 mm Hg lower for women and 3/1 mm Hg lower in older people compared with the combined group. Our study provides daytime ambulatory blood pressure thresholds that are slightly lower than equivalent clinic values. Clinic blood pressure measurements taken by doctors were considerably higher than those taken by trained staff and therefore gave inappropriate estimates of ambulatory thresholds. These results provide a framework for the diagnosis and management of hypertension using ambulatory blood pressure values.

  13. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  14. Sedimentary mercury (Hg) in the marginal seas adjacent to Chinese high-Hg emissions: Source-to-sink, mass inventory, and accumulation history.

    Science.gov (United States)

    Kim, Jihun; Lim, Dhongil; Jung, Dohyun; Kang, Jeongwon; Jung, Hoisoo; Woo, Hanjun; Jeong, Kapsik; Xu, Zhaokai

    2018-03-01

    We comprehensively investigated sedimentary Hg in Yellow and East China Seas (YECSs), which constitute potentially important depocenters for large anthropogenic Hg emissions from mainland China. A large dataset of Al-TOC-Hg concentrations led to an in-depth understanding of sedimentary Hg in the entire YECSs, including distribution and its determinants, source-to-sink, background levels, inventory in flux and budget, and accumulation history. Especially, the net atmospheric Hg flux to the sediments was estimated to be 1.3 × 10 -5  g/m 2 /yr, which corresponded reasonably well to that calculated using a box model. About 21.2 tons of atmospheric Hg (approximately 4% of the total anthropogenic atmospheric Hg emissions from China) were buried annually in the YECS basin. This result implies that most of atmospheric Hg from China is transferred to the surface of the Pacific (including the East/Japan Sea and South China Sea) by the westerlies and, consequently, can play a critical role in open-sea aquatic ecosystems. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Inter-arm blood pressure difference in type 2 diabetes: a barrier to effective management?

    Science.gov (United States)

    Clark, Christopher E; Greaves, Colin J; Evans, Philip H; Dickens, Andy; Campbell, John L

    2009-06-01

    Previous studies have identified a substantial prevalence of a blood pressure difference between arms in various populations, but not patients with type 2 diabetes. Recognition of such a difference would be important as a potential cause of underestimation of blood pressure. To measure prevalence of an inter-arm blood pressure difference in patients with type 2 diabetes, and to estimate how frequently blood pressure measurements could be erroneously underestimated if an inter-arm difference is unrecognised. Cross-sectional study. Five surgeries covered by three general practices, Devon, England. Patients with type 2 diabetes underwent bilateral simultaneous blood pressure measurements using a validated protocol. Mean blood pressures were calculated for each arm to derive mean systolic and diastolic differences, and to estimate point prevalence of predefined magnitudes of difference. A total of 101 participants were recruited. Mean age was 66 years (standard deviation [SD] = 13.9 years); 59% were male, and mean blood pressure was 138/79 mmHg (SD = 15/10 mmHg). Ten participants (10%; 95% confidence interval [CI] = 4 to 16) had a systolic inter-arm difference > or =10 mmHg; 29 (29%; 95% CI = 20 to 38) had a diastolic difference >/=5 mmHg; and three (3%; 95% CI = 0 to 6) a diastolic difference > or =10 mmHg. No confounding variable was observed to account for the magnitude of an inter-arm difference. A systolic inter-arm difference > or =10 mmHg was observed in 10% of patients with diabetes. Failure to recognise this would misclassify half of these as normotensive rather than hypertensive using the lower-reading arm. New patients with type 2 diabetes should be screened for an inter-arm blood pressure difference.

  16. Intrathoracic Pressure Regulator for Blood Loss

    Science.gov (United States)

    2016-05-24

    hepatitis A antibody, and human immunodeficiency virus antibody), urine tests (drug screen I-abuse, marijuana, and a pregnancy test), and a 12-lead... sodium chloride; 250 mL over 2.5 minutes) were administered if systolic BP < 85 mmHg. Blood pressure, other hemodynamics, UO, and total amount of

  17. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  18. 196Hg and 202Hg isotopic ratios in chondrites: revisited

    International Nuclear Information System (INIS)

    Jovanovic, S.; Reed, G.W. Jr.

    1976-01-01

    Additional evidence for an isotopically anomalous Hg fraction in unequilibrated meteorites has been obtained using neutron activation to produce 196 Hg and 202 Hg followed by stepwise heating to extract the Hg. In the latest experiments Allende matrix samples released the anomalous Hg but various high-temperature inclusions did not. Nucleogenetic processes are suggested as the probable cause of the anomaly. (Auth.)

  19. Safer laparoscopic trocar entry: it's all about pressure.

    Science.gov (United States)

    Tsaltas, Jim; Pearce, Scott; Lawrence, Anthony; Meads, Alan; Mezzatesta, Joseph; Nicolson, Scott

    2004-08-01

    This prospective observational study aimed to assess the feasibility of adapting peritoneal hyperdistention to 25 mmHg during laparoscopy in an Australian hospital environment. A total of 1150 consecutive diagnostic or operative laparoscopies were performed. All cases were monitored for early detection of untoward physiological changes. All patients had Veress needle insufflation with distension to 25 mmHg prior to insertion of the primary trocar. No patients experienced any surgical entry complications or adverse clinical effects noted during anaesthetic. The aim of the current study is to assess the feasibility and safety of increasing the peritoneal insufflation pressure to 25 mmHg for primary trocar insertion.

  20. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  1. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  2. Compressor Research Facility F100 High Pressure Compressor Inlet Total Pressure and Swirl Profile Simulation.

    Science.gov (United States)

    1984-10-01

    1627 VANE ANGLE- U SCREE 4 S,,, L53 S 6 4 NSW, 153 Figure 139. Total Pressure Profile Figure 140. Total Pressure Profile (Phase III), PSV = 250 (Phase...STATION 2.5 , PT. 1-1574- 1585 VANE ANGLE- 15 PT. 0-IMB 8- 150 VANE ANGLE= 21SCREENS- 4 I 54 SDIENS-4 X L53 Figure 137. Total Pressure Profile Figure 138...A 53: if 1-4;2.A 54: for L-10 to 16;wrt 709,"ASVN5SOIVFIVSIVT3VS"for J-l to 5 *55: r!-’ 709,E[A,L,J);nex~t ,I-r~eXt f! *56: if 1-1;wrt 709," TD )"red

  3. Phonons and their dispersion in model ferroelastics Hg2Hal2

    Science.gov (United States)

    Roginskii, E. M.; Kvasov, A. A.; Markov, Yu. F.; Smirnov, M. B.

    2012-05-01

    Dispersion relations of the acoustic and optical phonon frequencies have been calculated and plotted, and the density of states of the phonon spectrum of Hg2Cl2 and Hg2Br2 crystals has been derived. The effect of hydrostatic pressure on the frequencies of acoustic and optical phonons and their dispersion has been theoretically analyzed. It has been found that an increase in the pressure leads to a strong softening of the slowest acoustic TA branch (the soft mode) at the X point of the Brillouin zone boundary, which is consistent with the phenomenological Landau theory and correlates with experiment.

  4. Does dysfunction of the autonomic nervous system affect success of renal denervation in reducing blood pressure?

    Science.gov (United States)

    Fricke, Lisa; Petroff, David; Desch, Steffen; Lurz, Philipp; Reinhardt, Sebastian; Sonnabend, Melanie; Classen, Joseph; Baum, Petra

    2017-01-01

    Renal denervation is an interventional approach aiming to reduce high blood pressure. Its efficacy is subject of controversial debate. We analyzed autonomic function in patients undergoing renal denervation to identify responders. A total of 21 patients with treatment-resistant hypertension scheduled for renal denervation were included. Heart rate variability, pupillary function and sympathetic skin response were examined prior to intervention. Before and 1 or 3 months after intervention, 24-h ambulatory blood pressure readings were taken. Patients were stratified according to sympathetic nervous system function. Sympathetic activity was reduced in 12 participants (group 1) and normal or enhanced in nine patients (group 2). The mean of daytime systolic blood pressure decreased in groups 1 and 2 from 168 to 157 mmHg (95% confidence interval for difference, 1-21 mmHg, p = 0.035) and from 166 to 145 mmHg (8-34 mmHg, p = 0.005), respectively. In a linear model, blood pressure reduction was 11.3 mmHg (0.3-22 mmHg) greater in group 2 than in group 1 (p = 0.045). Patients with preexisting reduced activity of the sympathetic nervous system benefited less from renal denervation.

  5. Does dysfunction of the autonomic nervous system affect success of renal denervation in reducing blood pressure?

    Directory of Open Access Journals (Sweden)

    Lisa Fricke

    2017-04-01

    Full Text Available Objectives: Renal denervation is an interventional approach aiming to reduce high blood pressure. Its efficacy is subject of controversial debate. We analyzed autonomic function in patients undergoing renal denervation to identify responders. Methods: A total of 21 patients with treatment-resistant hypertension scheduled for renal denervation were included. Heart rate variability, pupillary function and sympathetic skin response were examined prior to intervention. Before and 1 or 3 months after intervention, 24-h ambulatory blood pressure readings were taken. Results: Patients were stratified according to sympathetic nervous system function. Sympathetic activity was reduced in 12 participants (group 1 and normal or enhanced in nine patients (group 2. The mean of daytime systolic blood pressure decreased in groups 1 and 2 from 168 to 157 mmHg (95% confidence interval for difference, 1–21 mmHg, p = 0.035 and from 166 to 145 mmHg (8–34 mmHg, p = 0.005, respectively. In a linear model, blood pressure reduction was 11.3 mmHg (0.3–22 mmHg greater in group 2 than in group 1 (p = 0.045. Conclusion: Patients with preexisting reduced activity of the sympathetic nervous system benefited less from renal denervation.

  6. Initial in vitro testing of a paediatric continuous-flow total artificial heart.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader

    2018-06-01

    Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.

  7. Accuracy of home blood pressure readings: monitors and operators.

    Science.gov (United States)

    Stryker, Trina; Wilson, Merne; Wilson, Thomas W

    2004-06-01

    To evaluate the accuracy of automated digital blood pressure monitoring devices and operators in the community. Also, we tested the effects of a simple education program, and looked for arm-arm differences. Subjects who had bought their own automated digital blood pressure monitor were recruited via an advertisement in the local newspaper. On arrival, they were asked to record their blood pressure exactly as they would at home. The investigator noted any technique deficiencies then corrected them. Blood pressures were then recorded by the investigator and the subject, on opposite arms, simultaneously, and repeated with the arms switched. Finally, subjects recorded their blood pressure again. The subjects' readings were compared to the average of monitor and mercury readings using Bland-Altman methods. A total of 80 subjects were tested. Before educating, subjects' systolic blood pressure (SBP) readings were +5.8+/-6.4 (standard deviation) mmHg greater than the mean of all readings, and diastolic blood pressure (DBP) were +1.3+/-4.0 mmHg; after educating they were +1.3+/-4.0 and -1.3+/-2.7 respectively. The monitors, as a group, were accurate, and met British Hypertension Society and AAMI highest standards. We found no differences among monitors that had been validated (n=26) and those that had not. There were differences between the arms: 5.3+/-5.2 mmHg for SBP and 3.4+/-3.3 mmHg for DBP. Most patients had never been informed by anyone of proper blood pressure measuring techniques. We conclude that home blood pressure measurement, as practiced in our community, is prone to error, mostly due to mistakes by the operator. These can easily be corrected, so that readings become more accurate. Attention should be paid to arm-arm differences.

  8. A thermodynamic stability of bulk and epitaxial CdHgTe, ZnHgTe and MnHgTe solid solutions

    International Nuclear Information System (INIS)

    Dejbuk, V.G.; Dremlyuzhenko, S.G.; Ostapov, S.Eh.

    2005-01-01

    A thermodynamics of Cd 1-x Hg x Te, Zn x Hg 1-x Te and Mg x Hg 1-x Te alloys has been investigated for a delta-lattice parameter model. The phase diagrams obtained show the stability of Cd 1-x Hg x Te, Zn x Hg 1-x Te in the whole range of compositions, alongside with a miscibility gap for Mn x Hg 1-x Te being of 0.35 x Hg 1-x Te/CdTe and Mn x Hg 1-x Te/Cd 0.96 Zn 0.04 Te epitaxial films result in lowering critical temperatures and narrowing the miscibility gap [ru

  9. Results of ambulatory arterial blood pressure monitoring in children with obesity

    Directory of Open Access Journals (Sweden)

    Faruk Öktem

    2010-12-01

    Full Text Available Objectives: The relationship between obesity and essential hypertension is well known. In this study, we aimed to evaluate ambulatory arterial blood pressure monitoring of obese and non-obese children who had similar demographic characteristics.Materials and methods: Seventy one children and adolescents (n=39 obesity, n=32 controls were studied. Blood pressure of the children were measured by 24 hour ambulatory blood pressure monitoring device.Results: Obese children had significantly higher mean blood pressure values (systolic 121.9±11.7 mmHg, diastolic 70.2±5.3 mmHg than control subjects (systolic 109.3±6.7 mmHg, diastolic 65.1±4.6 mmHg, p0.05. Blood pressure load was found to be increased in obese children compared to the controls (%13.6±12.9 and %2.6±3.4, respectively; p<0.05. Serum total cholesterol and LDL-cholesterol levels of obese children (181.1±33.4 and 131.1±23.1mg/dl were significantly higher than those of the controls (134.3±11.1 and 103.3±14.2 mg/dl, p<0.05.Conclusions: Obesity in children and adolescents should not be regarded as variations of normality, but as abnormality with an extremely high risk for the development of hypertension and hyperlipidemia in adulthood.

  10. Zuotai and HgS differ from HgCl2 and methyl mercury in Hg accumulation and toxicity in weanling and aged rats.

    Science.gov (United States)

    Zhang, Bin-Bin; Li, Wen-Kai; Hou, Wei-Yu; Luo, Ya; Shi, Jing-Zhen; Li, Cen; Wei, Li-Xin; Liu, Jie

    2017-09-15

    Mercury sulfides are used in Ayurvedic medicines, Tibetan medicines, and Chinese medicines for thousands of years and are still used today. Cinnabar (α-HgS) and metacinnabar (β-HgS) are different from mercury chloride (HgCl 2 ) and methylmercury (MeHg) in their disposition and toxicity. Whether such scenario applies to weanling and aged animals is not known. To address this question, weanling (21d) and aged (450d) rats were orally given Zuotai (54% β-HgS, 30mg/kg), HgS (α-HgS, 30mg/kg), HgCl 2 (34.6mg/kg), or MeHg (MeHgCl, 3.2mg/kg) for 7days. Accumulation of Hg in kidney and liver, and the toxicity-sensitive gene expressions were examined. Animal body weight gain was decreased by HgCl 2 and to a lesser extent by MeHg, but unaltered after Zuotai and HgS. HgCl 2 and MeHg produced dramatic tissue Hg accumulation, increased kidney (kim-1 and Ngal) and liver (Ho-1) injury-sensitive gene expressions, but such changes are absent or mild after Zuotai and HgS. Aged rats were more susceptible than weanling rats to Hg toxicity. To examine roles of transporters in Hg accumulation, transporter gene expressions were examined. The expression of renal uptake transporters Oat1, Oct2, and Oatp4c1 and hepatic Oatp2 was decreased, while the expression of renal efflux transporter Mrp2, Mrp4 and Mdr1b was increased following HgCl 2 and MeHg, but unaffected by Zuotai and HgS. Thus, Zuotai and HgS differ from HgCl 2 and MeHg in producing tissue Hg accumulation and toxicity, and aged rats are more susceptible than weanling rats. Transporter expression could be adaptive means to reduce tissue Hg burden. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Blood pressure standards for Saudi children and adolescents

    International Nuclear Information System (INIS)

    AlSalloum, Abdullah A.; El Mouzan, Mohammad I.; AlHerbish, Abdullah S.; AlOmar, Ahmad A.; Qurashi, Mansour M.

    2009-01-01

    Blood pressure levels may vary in children because of genetic, ethnic and socioeconomic factors. To date, there have been no large national studies in Saudi Arabia on blood pressure in children. Therefore, we sought to establish representative blood pressure reference centiles for Saudi Arabian children and adolescents. We selected a sample of children and adolescents aged from birth to 18 years by multi-stage probability sampling of the Saudi population. The selected sample represented Saudi children from the whole country. Data were collected through a house-to-house survey of all selected households in all 13 regions in the country. Data were analyzed to study the distribution pattern of systolic (SBP) and diastolic blood pressure (DBP) and to develop reference values. The 90th percentile of SBP and DBP values for each age were compared with values from a Turkish and an American study. A total of 16 226 Saudi children and adolescents from birth to 18 years were studied. Blood pressure rose steadily with age in both boys and girls. The average annual increase in SBP was 1.66 mm Hg for boys and1.44 mm Hg for girls. The average annual increase in DBP was 0.83 mm Hg for boys and 0.77 mm Hg for girls. DBP rose sharply in boys at the age of 18 years. Values for the 90th percentile of both SBP and DBP varied in Saudi children from their Turkish and American counterparts for all age groups. Blood pressure values in this study differed from those from other studies in developing countries and in the United States, indicating that comparison across studies is difficult and from that every population should use their own normal standards to define measured blood pressure levels in children. (author)

  12. Mean intraocular pressure in hypertensive adults

    International Nuclear Information System (INIS)

    Irum, S.; Malik, A.M.; Saeed, M.

    2015-01-01

    To determine the mean Intraocular Pressure (IOP) in already diagnosed adult hypertensive patients with different grades of hypertension. Study Design: Cross-sectional descriptive study. Place and Duration of Study: Combined Military Hospital, Lahore, from March 2012 to Aug 2012. Patients and Methods: A total of 178 already diagnosed hypertensive patients were selected. A detailed history of ocular or systemic diseases was taken. Intraocular pressure was measured with help of Goldmann applanation tonometer. Three consecutive readings of IOP of each eye were taken at 30 minutes interval and mean calculated. Blood pressure was recorded in seated position from right upper arm, by mercury sphygmomanometer. Blood pressure measurements were determined by taking the mean value of three systolic and diastolic readings. Results: The results of intraocular pressure (IOP) between various grades of hypertension were determined. There was an increase in mean IOP with rise in blood pressure. The subjects with grade I hypertension showed a mean IOP of 13.95 ± 3.74 mmHg, while grade II and grade III hypertensive subjects had mean IOPs as 18.10 ± 3.32 and 20.21 ± 2.52 mmHg respectively. Conclusion: A higher value of mean IOP was found with increase in systolic and diastolic blood pressures. (author)

  13. Factors associated with blood oxygen partial pressure and carbon dioxide partial pressure regulation during respiratory extracorporeal membrane oxygenation support: data from a swine model.

    Science.gov (United States)

    Park, Marcelo; Mendes, Pedro Vitale; Costa, Eduardo Leite Vieira; Barbosa, Edzangela Vasconcelos Santos; Hirota, Adriana Sayuri; Azevedo, Luciano Cesar Pontes

    2016-01-01

    The aim of this study was to explore the factors associated with blood oxygen partial pressure and carbon dioxide partial pressure. The factors associated with oxygen - and carbon dioxide regulation were investigated in an apneic pig model under veno-venous extracorporeal membrane oxygenation support. A predefined sequence of blood and sweep flows was tested. Oxygenation was mainly associated with extracorporeal membrane oxygenation blood flow (beta coefficient = 0.036mmHg/mL/min), cardiac output (beta coefficient = -11.970mmHg/L/min) and pulmonary shunting (beta coefficient = -0.232mmHg/%). Furthermore, the initial oxygen partial pressure and carbon dioxide partial pressure measurements were also associated with oxygenation, with beta coefficients of 0.160 and 0.442mmHg/mmHg, respectively. Carbon dioxide partial pressure was associated with cardiac output (beta coefficient = 3.578mmHg/L/min), sweep gas flow (beta coefficient = -2.635mmHg/L/min), temperature (beta coefficient = 4.514mmHg/ºC), initial pH (beta coefficient = -66.065mmHg/0.01 unit) and hemoglobin (beta coefficient = 6.635mmHg/g/dL). In conclusion, elevations in blood and sweep gas flows in an apneic veno-venous extracorporeal membrane oxygenation model resulted in an increase in oxygen partial pressure and a reduction in carbon dioxide partial pressure 2, respectively. Furthermore, without the possibility of causal inference, oxygen partial pressure was negatively associated with pulmonary shunting and cardiac output, and carbon dioxide partial pressure was positively associated with cardiac output, core temperature and initial hemoglobin.

  14. 199Hg Moessbauer measurements on mercury, alloys and Hg-fluorides

    International Nuclear Information System (INIS)

    Wurtinger, W.; Kankeleit, E.

    1979-01-01

    The Moessbauer effect on the 158 keV 5/2 - -1/2 - transition in 199 Hg, of the order of 10 ppm, has been studied using the current integration technique. The isomer shift between the Hg(I)- and Hg(II)-fluorides as well as the quadrupole splitting in Hg 2 Pt and Hg 2 F 2 are interpreted in terms of relativistic Hartree-Fock-Slater and Molecular Orbital calculations. The following nuclear parameters could be derived: Δ[r 2 ] = (3.2+-1.1) 10 -3 fm 2 and Q(5/2 - ) = (-0.8+-0.4)b. Evidence for an oblate triaxially deformed 199 Hg nucleus is derived from particle plus rotor calculations. (orig.)

  15. Impact of Land Use on the Mobility of Hg Species in Different Compartments of a Tropical Watershed in Brazil.

    Science.gov (United States)

    de Lima, Clara Ayume Ito; de Almeida, Marcelo Gomes; Pestana, Inacio Abreu; Bastos, Wanderley R; do Nascimento Recktenvald, Maria Cristina Nery; de Souza, Cristina Maria Magalhães; Pedrosa, Paulo

    2017-11-01

    This study evaluated the levels of total Hg and CH 3 Hg + from a comprehensive perspective, considering the retention, leaching, and deposition of these contaminants in the main compartments (soil, plant litter, and sediment) of three landscapes (Atlantic Forest, pasture, and agricultural area) in a watershed in northern Rio de Janeiro State, Brazil. Variables analyzed were total Hg, CH 3 Hg + , organic carbon, total nitrogen, grain size, and surface area. In soil samples, total Hg levels were the highest in agricultural soil followed by forest soil and pasture (97.3, 87.6, and 77.1 ng g -1 , respectively), and CH 3 Hg + was lower than 1.7%. Total Hg levels in leaf litter varied between 22.6 and 34.2 ng g -1 , and CH 3 Hg + was 4.37%. In sediment, Hg (60-180 ng g -1 ) and CH 3 Hg + (Hg species, and the effect of each variable varied with the landscape, showing that plant cover should not be ignored in investigations related to Hg species retention in a watershed. The landscapes surveyed in the present study clearly influence the quantitative and qualitative distribution of Hg species. On the other hand, anthropic processes associated with changes in soil use did not have any critical effects on the absolute levels of total Hg and CH 3 Hg + , meaning that the landscapes evaluated seem to represent the background concentration of these chemical species for the evaluated watershed.

  16. Noise exposure in occupational setting associated with elevated blood pressure in China

    Directory of Open Access Journals (Sweden)

    Shuchang Chen

    2017-01-01

    Full Text Available Abstract Background Hypertension is the primary out-auditory adverse outcome caused due to occupational noise exposure. This study investigated the associations of noise exposure in an occupational setting with blood pressure and risk of hypertension. Methods A total of 1,390 occupational noise-exposed workers and 1399 frequency matched non-noise-exposed subjects were recruited from a cross-sectional survey of occupational noise-exposed and the general population, respectively. Blood pressure was measured using a mercury sphygmomanometer following a standard protocol. Multiple logistic regression was used to calculate the odds ratio (OR and 95% confidence interval (CI of noise exposure adjusted by potential confounders. Results Noise-exposed subjects had significantly higher levels of systolic blood pressure(SBP (125.1 ± 13.9 mm Hg and diastolic blood pressure (DBP (77.6 ± 10.7 mm Hg than control subjects (SBP: 117.2 ± 15.7 mm Hg, DBP: 70.0 ± 10.5 mm Hg (P  0.05. Conclusions Occupational noise exposure was associated with higher levels of SBP, DBP, and the risk of hypertension. These findings indicate that effective and feasible measures should be implemented to reduce the risk of hypertension caused by occupational noise exposure.

  17. Electronic properties of liquid Hg-In alloys : Ab-initio molecular dynamics study

    International Nuclear Information System (INIS)

    Sharma, Nalini; Ahluwalia, P. K.; Thakur, Anil

    2016-01-01

    Ab-initio molecular dynamics simulations are performed to study the structural properties of liquid Hg-In alloys. The interatomic interactions are described by ab-initio pseudopotentials given by Troullier and Martins. Three liquid Hg-In alloys (Hg_1_0In_9_0, Hg_3_0In_7_0_,_. Hg_5_0In_5_0, Hg_7_0In_3_0, and Hg_9_0Pb_1_0) at 299 K are considered. The calculated results for liquid Hg (l-Hg) and lead (l-In) are also drawn. Along with the calculated results of considered five liquid alloys of Hg-In alloy. The results obtained from electronic properties namely total density of state and partial density of states help to find the local arrangement of Hg and In atoms and the presence of liquid state in the considered five alloys.

  18. The measurement of digital systolic blood pressure by strain gauge technique

    DEFF Research Database (Denmark)

    Nielsen, P E; Bell, G; Lassen, N A

    1972-01-01

    The systolic blood pressure on the finger, toe, and ankle has been measured by a strain gauge technique in 10 normal subjects aged 17-31 years and 14 normal subjects aged 43-57 years. The standard deviation in repeated measurements lies between 2 and 6 mm Hg. The finger pressure in the younger...... group was significantly higher than the corresponding arm pressure (+ 9.3 mm Hg, S.D. 6.8), but equalled this in the older group (- 0.5 mm Hg, S.D. 6.6). In the two groups the ankle pressures were + 19.3 mm Hg (S.D. 7.5) and + 23.6 mm Hg (S.D. 9.5) higher than the systolic arm pressures. The toe...... pressures were lower than the arm pressures, in the two groups - 4.8 mm Hg (S.D. 6.6) and - 9.8 mm Hg (S.D. 10.7) respectively. The ankle-toe gradient was in the younger group 24.3 mm Hg (S.D. 7.3) and in the older group 33.3 mm Hg (S.D. 12.1). Using mean minus 2.5 X S.D. as the lower limit of normality...

  19. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  20. A Structural Study of the Pseudo-Binary Mercury Chalcogenide Alloy HgSe_{0.7}S_{0.3} at High Pressure

    CERN Document Server

    Kozlenko, D P; Ehm, L; Knorr, K; Hull, S; Shchennikov, V V; Voronin, V I

    2002-01-01

    The structure of the pseudo-binary mercury chalcogenide alloy HgSe_{0.7}S_{0.3} has been studied by means of X-ray and neutron powder diffraction at pressure up to 8.5 GPa. A phase transition from the cubic zinc blende structure to the hexagonal cinnabar structure was observed at P{\\sim}1 GPa. The obtained structural parameters were used for the analysis of the geometrical relationship between the zinc blende and the cinnabar phases. The zinc blende-cinnabar phase transition is discussed in the framework of Landau theory of the phase transitions. It was found that the possible order parameter for the structural transformation is the spontaneous strain e_{4}. This assignment agrees with previously observed high pressure behaviour of the elastic constants of other mercury chalcogenides.

  1. A structural study of the pseudo-binary mercury chalcogenide alloy HgSe0.7S0.3 at high pressure

    International Nuclear Information System (INIS)

    Kozlenko, D.P.; Savenko, B.N.; Ehm, L.; Knorr, K.; Hull, S.; Shchennikov, V.V.; Voronin, V.I.

    2002-01-01

    The structure of the pseudo-binary mercury chalcogenide alloy HgSe 0.7 S 0.3 has been studied by means of X-ray and neutron powder diffraction at pressure up to 8.5 GPa. A phase transition from the cubic zinc blende structure to the hexagonal cinnabar structure was observed at P∼1 GPa. The obtained structural parameters were used for the analysis of the geometrical relationship between the zinc blende and the cinnabar phases. The zinc blende-cinnabar phase transition is discussed in the framework of the Landau theory of phase transitions. It was found that the possible order parameter for the structural transformation is the spontaneous strain e 4 . This assignment agrees with previously observed high pressure behaviour of the elastic constants of other mercury chalcogenides

  2. MOCVD growth of CdTe and HgTe on GaAs in a vertical, high-speed, rotating-disc reactor

    International Nuclear Information System (INIS)

    Tompa, G.S.; Nelson, C.R.; Reinert, P.D.; Saracino, M.A.; Terrill, L.A.; Colter, P.C.

    1989-01-01

    The metalorganic chemical vapor deposition (MOCVD) growth of CdTe and HgTe on GaAs (111) and (100) substrates in a vertical, high-speed, rotating-disc reactor was investigated. A range of total reactor pressure, carrier gas flow rate, chemical concentrations, deposition temperature, and rotation rate have been investigated in an attempt to optimize growth conditions. Diisopropyltelluride (DIPTe) and Dimethylcadmium (DMCd) were used as growth precursors. Thickness uniformity varies less than +/- 1.5% over 50 mm diameter wafers. Films having FWHM X-ray rocking curves less than 90 arcsec were obtained on GaAs (111) substrates. The films have excellent surface morphology, exhibiting less than 5 x 10 4 cm - 2 orange peel dents which are much-lt 1 μm in size. An elemental mercury source was added to the growth system. Initial results for the growth of HgTe and HgCdTe are discussed

  3. Method Performance of Total Mercury (Hg) Testing in the Biological Samples by Using Cold Vapour Atomic Absorption Spectrophotometer (CV-AAS)

    International Nuclear Information System (INIS)

    Susanna TS; Samin

    2007-01-01

    Method performance (validation) of total mercury (Hg) testing in the biological samples by using cold vapour atomic absorption spectrophotometer (CV-AAS) has been done. The objective of this research is to know the method performance of CV-AAS as one of points for the accreditation testing of laboratory according IS0/IEC 17025-2005. The method performance covering limit of detection (LOD), accuracy, precision and bias. As a standard material used SRM Oyster Tissue 15660 from Winopal Forshung Germany, whereas the biological samples were human hair. In principle of mercury testing for solid samples using CV-AAS is dissolving this sample and standard with 10 mL HNO 3 supra pure into a closed quartz tube and heating at 150 °C for 4 hours. The concentration of mercury in each samples was determined at the condition of operation were stirring time (T 1 ) 70 seconds, delay time (T 2 ) 15 seconds, heating time (T 3 ) 13 seconds and cooling time (T 4 ) of 25 seconds. Mercury ion in samples are reduced with SnCl 2 10 % in H 2 SO 4 20 %, and then the vapour of mercury from reduction is passed in NaOH 20 % solution and aquatridest. The result of method performance were: limit of detection (LOD) = 0.085 ng, accuracy 99.70 %, precision (RSD) = 1.64 % and bias = 0.30 %. From the validation result showed that the content of mercury total was in the range of certified values. The total mercury content (Hg) in human hair were varied from 406.93 - 699.07 ppb. (author)

  4. Risk Stratification by Ambulatory Blood Pressure Monitoring Across JNC Classes of Conventional Blood Pressure

    DEFF Research Database (Denmark)

    Brguljan-Hitij, Jana; Thijs, Lutgarde; Li, Yan

    2014-01-01

    BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (<120/<80 mm Hg), prehypertension (120-139/80-89 mm Hg), and hypertension (≥140/≥90 mm Hg). METHODS: To assess the potential differential contribution of ambulatory blood pressure (ABP) in predict......BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (ABP......%) and of cardiovascular (-34%), cardiac (-33%), or cerebrovascular (-47%) events. Multivariable-adjusted hazard ratios (HRs) for stroke associated with 24-hour and daytime diastolic ABP (+5 mm Hg) were higher (P ≤ 0.045) in normotension than in prehypertension and hypertension (1.98 vs.1.19 vs.1.28 and 1.73 vs.1.09 vs. 1.......24, respectively) with similar trends (0.03 ≤ P ≤ 0.11) for systolic ABP (+10 mm Hg). However, HRs for fatal endpoints and cardiac events associated with ABP did not differ significantly (P ≥ 0.13) across CBP categories. Of normotensive and prehypertensive participants, 7.5% and 29.3% had masked hypertension...

  5. Studies of the 198Hg(d,d') and 198Hg(d,p) reactions

    Science.gov (United States)

    Diaz Varela, Alejandra; Garrett, P. E.; Rand, E. T.; Ball, G. C.; Bilstein, V.; Laffoley, A. T.; Maclean, A. D.; Svensson, C. E.; Faestermann, T.; Hertenberger, R.; Wirth, H.-F.

    2017-09-01

    Limits on the electric dipole moment (EDM) continue to decrease for 199Hg, the most stringent upper limit for a nuclear EDM to date. The experimental limit on the observed atomic EDM for 199Hg is converted to a limit on the nuclear EDM via a calculation of the Schiff moment, requiring knowledge of the nuclear structure of 199Hg. The E 3 and E 1 strength distributions to the ground state of 199Hg, and E 2 transitions amongst excited states, would be ideal information to further constrain 199Hg Schiff moment theoretical models. The high level density of 199Hg makes those determinations challenging, however the similar information can be obtained from exploring surrounding even-even Hg isotopes. As part of a campaign to study the Hg isotopes near 199Hg, two experiments, 198Hg(d,d') 198Hg and 198Hg(d,p)199Hg reaction were performed using the Q3D spectrograph at the Maier-Leibnitz Laboratory (MLL) at Garching, Germany. A 22 MeV deuterium beam was used to impinge a 198Hg32S target. The (d,d') reaction allows us to probe the desired E 2 and E 3 matrix elements, while the (d,p) reaction provides information on the neutron single-particle states of 199Hg.

  6. Photosynthetic pigments and peroxidase activity of Lepidium sativum L. during assisted Hg phytoextraction.

    Science.gov (United States)

    Smolinska, Beata; Leszczynska, Joanna

    2017-05-01

    The study was conducted to evaluate metabolic answer of Lepidium sativum L. on Hg, compost, and citric acid during assisted phytoextraction. The chlorophyll a and b contents, total carotenoids, and activity of peroxidase were determined in plants exposed to Hg and soil amendments. Hg accumulation in plant shoots was also investigated. The pot experiments were provided in soil artificially contaminated by Hg and/or supplemented with compost and citric acid. Hg concentration in plant shoots and soil substrates was determined by cold vapor atomic absorption spectroscopy (CV-AAS) method after acid mineralization. The plant photosynthetic pigments and peroxidase activity were measured by standard spectrophotometric methods. The study shows that L. sativum L. accumulated Hg in its aerial tissues. An increase in Hg accumulation was noticed when soil was supplemented with compost and citric acid. Increasing Hg concentration in plant shoots was correlated with enhanced activation of peroxidase activity and changes in total carotenoid concentration. Combined use of compost and citric acid also decreased the chlorophyll a and b contents in plant leaves. Presented study reveals that L. sativum L. is capable of tolerating Hg and its use during phytoextraction assisted by combined use of compost and citric acid lead to decreasing soil contamination by Hg.

  7. Mercury profiles in sediment from the marginal high of Arabian Sea: an indicator of increasing anthropogenic Hg input.

    Science.gov (United States)

    Chakraborty, Parthasarathi; Vudamala, Krushna; Chennuri, Kartheek; Armoury, Kazip; Linsy, P; Ramteke, Darwin; Sebastian, Tyson; Jayachandran, Saranya; Naik, Chandan; Naik, Richita; Nath, B Nagender

    2016-05-01

    Total Hg distributions and its speciation were determined in two sediment cores collected from the western continental marginal high of India. Total Hg content in the sediment was found to gradually increase (by approximately two times) towards the surface in both the cores. It was found that Hg was preferentially bound to sulfide under anoxic condition. However, redox-mediated reactions in the upper part of the core influenced the total Hg content in the sediment cores. This study suggests that probable increase in authigenic and allogenic Hg deposition attributed to the increasing Hg concentration in the surface sediment in the study area.

  8. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  9. Association of Interarm Systolic Blood Pressure Difference with Atherosclerosis and Left Ventricular Hypertrophy

    Science.gov (United States)

    Su, Ho-Ming; Lin, Tsung-Hsien; Hsu, Po-Chao; Chu, Chun-Yuan; Lee, Wen-Hsien; Chen, Szu-Chia; Lee, Chee-Siong; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2012-01-01

    An interarm systolic blood pressure (SBP) difference of 10 mmHg or more have been associated with peripheral artery disease and adverse cardiovascular outcomes. We investigated whether an association exists between this difference and ankle-brachial index (ABI), brachial-ankle pulse wave velocity (baPWV), and echocardiographic parameters. A total of 1120 patients were included in the study. The bilateral arm blood pressures were measured simultaneously by an ABI-form device. The values of ABI and baPWV were also obtained from the same device. Clinical data, ABIdifference ≥10 mmHg were compared and analyzed. We performed two multivariate forward analyses for determining the factors associated with an interarm SBP difference ≥10 mmHg [model 1: significant variables in univariate analysis except left ventricular mass index (LVMI); model 2: significant variables in univariate analysis except ABIdifference ≥10 mmHg. Female, hypertension, and high body mass index were also associated with an interarm SBP difference ≥10 mmHg. Our study demonstrated that ABIdifference of 10 mmHg or more. Detection of an interarm SBP difference may provide a simple method of detecting patients at increased risk of atherosclerosis and left ventricular hypertrophy. PMID:22927905

  10. 46 CFR 53.12-1 - General (modifies HG-600 through HG-640).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false General (modifies HG-600 through HG-640). 53.12-1... HEATING BOILERS Instruments, Fittings, and Controls (Article 6) § 53.12-1 General (modifies HG-600 through HG-640). (a) The instruments, fittings and controls for heating boilers shall be as indicated in HG...

  11. Estimated Trans-Lamina Cribrosa Pressure Differences in Low-Teen and High-Teen Intraocular Pressure Normal Tension Glaucoma: The Korean National Health and Nutrition Examination Survey.

    Directory of Open Access Journals (Sweden)

    Si Hyung Lee

    Full Text Available To investigate the association between estimated trans-lamina cribrosa pressure difference (TLCPD and prevalence of normal tension glaucoma (NTG with low-teen and high-teen intraocular pressure (IOP using a population-based study design.A total of 12,743 adults (≥ 40 years of age who participated in the Korean National Health and Nutrition Examination Survey (KNHANES from 2009 to 2012 were included. Using a previously developed formula, cerebrospinal fluid pressure (CSFP in mmHg was estimated as 0.55 × body mass index (kg/m2 + 0.16 × diastolic blood pressure (mmHg-0.18 × age (years-1.91. TLCPD was calculated as IOP-CSFP. The NTG subjects were divided into two groups according to IOP level: low-teen NTG (IOP ≤ 15 mmHg and high-teen NTG (15 mmHg < IOP ≤ 21 mmHg groups. The association between TLCPD and the prevalence of NTG was assessed in the low- and high-teen IOP groups.In the normal population (n = 12,069, the weighted mean estimated CSFP was 11.69 ± 0.04 mmHg and the weighted mean TLCPD 2.31 ± 0.06 mmHg. Significantly higher TLCPD (p < 0.001; 6.48 ± 0.27 mmHg was found in the high-teen NTG compared with the normal group. On the other hand, there was no significant difference in TLCPD between normal and low-teen NTG subjects (p = 0.395; 2.31 ± 0.06 vs. 2.11 ± 0.24 mmHg. Multivariate logistic regression analysis revealed that TLCPD was significantly associated with the prevalence of NTG in the high-teen IOP group (p = 0.006; OR: 1.09; 95% CI: 1.02, 1.15, but not the low-teen IOP group (p = 0.636. Instead, the presence of hypertension was significantly associated with the prevalence of NTG in the low-teen IOP group (p < 0.001; OR: 1.65; 95% CI: 1.26, 2.16.TLCPD was significantly associated with the prevalence of NTG in high-teen IOP subjects, but not low-teen IOP subjects, in whom hypertension may be more closely associated. This study suggests that the underlying mechanisms may differ between low-teen and high-teen NTG patients.

  12. Quadrupole moments of the 12+ isomers in 188Hg and 190Hg

    International Nuclear Information System (INIS)

    Dracoulis, G.D.; Lonnroth, T.; Vajda, S.; Dafni, E.; Schatz, G.

    1984-01-01

    The electric quadrupole interaction of the 12 + isomers in 188 Hg and 190 Hg has been measured in solid Hg. The quadrupole moments deduced, vertical strokeQ[ 188 Hg(12 + )]vertical stroke = 91(11) e fm 2 and vertical strokeQ[ 190 Hg(12 + )]vertical stroke = 117(14) e fm 2 suggest a possible change in γ-deformation due to the rotation alignment of the isub(13/2) quasi-neutrons. The temperature dependence of the electric field gradient tensor in Hg was also determined. (orig.)

  13. Intraperitoneal pressure: ascitic fluid and splanchnic vascular pressures, and their role in prevention and formation of ascites

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Stage, J G; Schlichting, P

    1980-01-01

    Seventeen patients with ascites due to cirrhosis underwent hepatic venous catheterization and pressure measurement in the ascitic fluid. Intraperitoneal fluid hydrostatic pressure (IFP) ranged 3.5-22, mean 11.2 mm Hg, and correlated closely to the pressure in the inferior vena cava (r = 0.97, P ... that ascitic fluid stems the pressures in the splanchnic venous vascular bed up to a higher level, but that the transmural hydrostatic pressure difference decreases simultaneously. The results are discussed in relation to the local 'oedema-preventing' mechanisms: (a) increased interstitial hydrostatic fluid.......001), which was on average 1.8 mmHg above that of ascitic fluid (P pressure (WHVP) (range 19-43, mean 32 mmHg) correlated directly to IFP (0.89, P

  14. Tracing aquatic bioavailable Hg in three different regions of China using fish Hg isotopes.

    Science.gov (United States)

    Liu, Cheng-Bin; Hua, Xiu-Bing; Liu, Hong-Wei; Yu, Ben; Mao, Yu-Xiang; Wang, Ding-Yong; Yin, Yong-Guang; Hu, Li-Gang; Shi, Jian-Bo; Jiang, Gui-Bin

    2018-04-15

    To trace the most concerned bioavailable mercury (Hg) in aquatic environment, fish samples were collected from three typical regions in China, including 3 rivers and 1 lake in the Tibetan Plateau (TP, a high altitude background region with strong solar radiation), the Three Gorges Reservoir (TGR, the largest artificial freshwater reservoir in China), and the Chinese Bohai Sea (CBS, a heavily human-impacted semi-enclosed sea). The Hg isotopic compositions in fish muscles were analyzed. The results showed that anthropogenic emissions were the main sources of Hg in fish from TGR and CBS because of the observed negative δ 202 Hg and positive Δ 199 Hg in these two regions (TGR, δ 202 Hg: - 0.72 to - 0.29‰, Δ 199 Hg: 0.15 - 0.52‰; CBS, δ 202 Hg: - 2.09 to - 0.86‰, Δ 199 Hg: 0.07 - 0.52‰). The relatively higher δ 202 Hg and Δ 199 Hg (δ 202 Hg: - 0.37 - 0.08‰, Δ 199 Hg: 0.50 - 1.89‰) in fish from TP suggested the insignificant disturbance from local anthropogenic activities. The larger slopes of Δ 199 Hg/Δ 201 Hg in fish from TGR (1.29 ± 0.14, 1SD) and TP (1.25 ± 0.06, 1SD) indicated methylmercury (MeHg) was produced and photo-reduced in the water column before incorporation into the fish. In contrast, the photoreduction of Hg 2+ was the main process in CBS (slope of Δ 199 Hg/Δ 201 Hg: 1.06 ± 0.06, 1SD). According to the fingerprint data of Hg isotopes, the most important source for aquatic bioavailable Hg in TP should be the long-range transported Hg, contrasting to the anthropogenic originated MeHg from surface sediments and runoffs in TGR and inorganic Hg from continental inputs in CBS. Therefore, the isotopic signatures of Hg in fish can provide novel clues in tracing sources and behaviors of bioavailable Hg in aquatic systems, which are critical for further understanding the biogeochemical cycling of Hg. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Diastolic coronary artery pressure-flow velocity relationships in conscious man.

    Science.gov (United States)

    Dole, W P; Richards, K L; Hartley, C J; Alexander, G M; Campbell, A B; Bishop, V S

    1984-09-01

    We characterised the diastolic pressure-flow velocity relationship in the normal left coronary artery of conscious man before and after vasodilatation with angiographic contrast medium. Phasic coronary artery pressure and flow velocity were measured in ten patients during individual diastoles (0.5 to 1.0 s) using a 20 MHz catheter-tipped, pulsed Doppler transducer. All pressure-flow velocity curves were linear over the diastolic pressure range of 110 +/- 15 (SD) mmHg to 71 +/- 7 mmHg (r = 0.97 +/- 0.01). In the basal state, values for slope and extrapolated zero flow pressure intercept averaged 0.35 +/- 0.12 cm X s-1 X mmHg-1 and 51.7 +/- 8.6 mmHg, respectively. Vasodilatation resulted in a 2.5 +/- 0.5 fold increase in mean flow velocity. The diastolic pressure-flow velocity relationship obtained during peak vasodilatation compared to that during basal conditions was characterised by a steeper slope (0.80 +/- 0.48 cm X s-1 X mmHg-1, p less than 0.001) and lower extrapolated zero flow pressure intercept (37.9 +/- 9.8 mmHg, p less than 0.05). Mean right atrial pressure for the group averaged 4.4 +/- 1.7 mmHg, while left ventricular end-diastolic pressure averaged 8.7 +/- 2.8 mmHg. These observations in man are similar to data reported in the canine coronary circulation which are consistent with a vascular waterfall model of diastolic flow regulation. In this model, coronary blood flow may be regulated by changes in diastolic zero flow pressure as well as in coronary resistance.

  16. Validation of the iHealth BP7 wrist blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Wang, Qing; Zhao, Huadong; Chen, Wan; Li, Ni; Wan, Yi

    2014-02-01

    The aim of this study was to validate the iHealth BP7 wireless wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 99 pairs of test device and reference blood pressure measurements (three pairs for each of the 33 participants) were obtained for validation. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. The device produced 66, 87, and 97 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 72, 93, and 99 mmHg for diastolic blood pressure (DBP), respectively. The mean±SD device-observer difference was -0.7±6.9 mmHg for SBP and -1.0±5.1 mmHg for DBP. The number of participants with two or three device-observer differences within 5 mmHg was 25 for SBP and 26 for DBP; furthermore, there were three participants for SBP and one participant for DBP, with none of the device-observer differences within 5 mmHg. On the basis of the validation results, the iHealth BP7 wireless wrist blood pressure monitor can be recommended for self-measurement in an adult population.

  17. Neutron Diffraction Study of the High-Tc Superconductor HgBa2CaCu2O6.3 under High Pressure

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Balagurov, A.M.; Savenko, B.N.; Capponi, J.J.; Glazkov, V.P.; Goncharenko, I.N.; Somenkov, V.A.

    1994-01-01

    The pressure dependence of the crystal structure of a powder sample of HgBa 2 CaCu 2 O 6.3 (T c =123 K) was studied in the pressure range of 0 to 3.6 GPa, using the DN-12 time-of-flight diffractometer at the IBR-2 pulsed reactor and a sapphire anvil cell chamber. At P=0 the results are in a good accordance with the published data. At P=3.0 and 3.6 GPa the best fit of the experimental data was achieved using the structural model with apical oxygen disordered in the (a,b) plane. The compressibility values of the lattice constants and selected bonds were calculated from the structural data. The highest absolute value of compressibility was found for the distance between the O atom layers. 12 refs., 6 figs., 3 tabs

  18. Skin interface pressure on the NATO litter.

    Science.gov (United States)

    Bridges, Elizabeth J; Schmelz, Joseph O; Mazer, Stephen

    2003-04-01

    The NATO litter serves as a transport device and hospital bed during all types of operations. Little is known about the skin interface pressure on this litter. The purpose of this study was to determine whether various types of padding on the litter and body position affect the peak skin interface pressure and the total body area exposed to interface pressures above 30 mm Hg at different body areas. Thirty-two subjects participated. A repeated measures design was used. The surface effect was statistically significant for all peak pressure and surface area analyses (repeated-measures analysis of variance, p patients if feasible. Preventive measures (turning, elevating the heels) are still required.

  19. Cholecalciferol treatment to reduce blood pressure in older patients with isolated systolic hypertension: the VitDISH randomized controlled trial.

    Science.gov (United States)

    Witham, Miles D; Price, Rosemary J G; Struthers, Allan D; Donnan, Peter T; Messow, Claudia-Martina; Ford, Ian; McMurdo, Marion E T

    2013-10-14

    Observational data link low 25-hydroxyvitamin D levels to both prevalent blood pressure and incident hypertension. No clinical trial has yet examined the effect of vitamin D supplementation in isolated systolic hypertension, the most common pattern of hypertension in older people. To test whether high-dose, intermittent cholecalciferol supplementation lowers blood pressure in older patients with isolated systolic hypertension. Parallel group, double-blind, placebo-controlled randomized trial. Primary care clinics and hospital clinics. Patients 70 years and older with isolated systolic hypertension (supine systolic blood pressure >140 mm Hg and supine diastolic blood pressure blood pressure, 24-hour blood pressure, arterial stiffness, endothelial function, cholesterol level, insulin resistance, and b-type natriuretic peptide level during 12 months. A total of 159 participants were randomized (mean age, 77 years). Mean baseline office systolic blood pressure was 163/78 mm Hg. Mean baseline 25-hydroxyvitamin D level was 18 ng/mL. 25-Hydroxyvitamin D levels increased in the treatment group compared with the placebo group (+8 ng/mL at 1 year, P blood pressure (−1 [−6 to 4]/−2 [−4 to 1] mm Hg at 3 months and 1 [−2 to 4]/0 [−2 to 2] mm Hg overall treatment effect). No significant treatment effect was evident for any of the secondary outcomes (24-hour blood pressure, arterial stiffness, endothelial function, cholesterol level, glucose level, and walking distance). There was no excess of adverse events in the treatment group, and the total number of falls was nonsignificantly lower in the group receiving vitamin D (36 vs 46, P = .24). Vitamin D supplementation did not improve blood pressure or markers of vascular health in older patients with isolated systolic hypertension. isrctn.org Identifier: ISRCTN92186858.

  20. Relationship between office and home blood pressure with increasing age: The International Database of HOme blood pressure in relation to Cardiovascular Outcome (IDHOCO).

    Science.gov (United States)

    Ntineri, Angeliki; Stergiou, George S; Thijs, Lutgarde; Asayama, Kei; Boggia, José; Boubouchairopoulou, Nadia; Hozawa, Atsushi; Imai, Yutaka; Johansson, Jouni K; Jula, Antti M; Kollias, Anastasios; Luzardo, Leonella; Niiranen, Teemu J; Nomura, Kyoko; Ohkubo, Takayoshi; Tsuji, Ichiro; Tzourio, Christophe; Wei, Fang-Fei; Staessen, Jan A

    2016-08-01

    Home blood pressure (HBP) measurements are known to be lower than conventional office blood pressure (OBP) measurements. However, this difference might not be consistent across the entire age range and has not been adequately investigated. We assessed the relationship between OBP and HBP with increasing age using the International Database of HOme blood pressure in relation to Cardiovascular Outcome (IDHOCO). OBP, HBP and their difference were assessed across different decades of age. A total of 5689 untreated subjects aged 18-97 years, who had at least two OBP and HBP measurements, were included. Systolic OBP and HBP increased across older age categories (from 112 to 142 mm Hg and from 109 to 136 mm Hg, respectively), with OBP being higher than HBP by ∼7 mm Hg in subjects aged >30 years and lesser in younger subjects (P=0.001). Both diastolic OBP and HBP increased until the age of ∼50 years (from 71 to 79 mm Hg and from 66 to 76 mm Hg, respectively), with OBP being consistently higher than HBP and a trend toward a decreased OBP-HBP difference with aging (P<0.001). Determinants of a larger OBP-HBP difference were younger age, sustained hypertension, nonsmoking and negative cardiovascular disease history. These data suggest that in the general adult population, HBP is consistently lower than OBP across all the decades, but their difference might vary between age groups. Further research is needed to confirm these findings in younger and older subjects and in hypertensive individuals.

  1. Photochemical reactions between mercury (Hg) and dissolved organic matter decrease Hg bioavailability and methylation.

    Science.gov (United States)

    Luo, Hong-Wei; Yin, Xiangping; Jubb, Aaron M; Chen, Hongmei; Lu, Xia; Zhang, Weihua; Lin, Hui; Yu, Han-Qing; Liang, Liyuan; Sheng, Guo-Ping; Gu, Baohua

    2017-01-01

    Atmospheric deposition of mercury (Hg) to surface water is one of the dominant sources of Hg in aquatic environments and ultimately drives methylmercury (MeHg) toxin accumulation in fish. It is known that freshly deposited Hg is more readily methylated by microorganisms than aged or preexisting Hg; however the underlying mechanism of this process is unclear. We report that Hg bioavailability is decreased by photochemical reactions between Hg and dissolved organic matter (DOM) in water. Photo-irradiation of Hg-DOM complexes results in loss of Sn(II)-reducible (i.e. reactive) Hg and up to an 80% decrease in MeHg production by the methylating bacterium Geobacter sulfurreducens PCA. Loss of reactive Hg proceeded at a faster rate with a decrease in the Hg to DOM ratio and is attributed to the possible formation of mercury sulfide (HgS). These results suggest a new pathway of abiotic photochemical formation of HgS in surface water and provide a mechanism whereby freshly deposited Hg is readily methylated but, over time, progressively becomes less available for microbial uptake and methylation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Equilibrium mercury isotope fractionation between dissolved Hg(II) species and thiol-bound Hg

    NARCIS (Netherlands)

    Wiederhold, Jan G.; Cramer, Christopher J.; Daniel, Kelly; Infante, Ivan; Bourdon, Bernard; Kretzschmar, Ruben

    2010-01-01

    Stable Hg isotope ratios provide a new tool to trace environmental Hg cycling. Thiols (-SH) are the dominant Hg-binding groups in natural organic matter. Here, we report experimental and computational results on equilibrium Hg isotope fractionation between dissolved Hg(II) species and thiol-bound

  3. Hemodynamics of a functional centrifugal-flow total artificial heart with functional atrial contraction in goats.

    Science.gov (United States)

    Shiga, Takuya; Shiraishi, Yasuyuki; Sano, Kyosuke; Taira, Yasunori; Tsuboko, Yusuke; Yamada, Akihiro; Miura, Hidekazu; Katahira, Shintaro; Akiyama, Masatoshi; Saiki, Yoshikatsu; Yambe, Tomoyuki

    2016-03-01

    Implantation of a total artificial heart (TAH) is one of the therapeutic options for the treatment of patients with end-stage biventricular heart failure. There is no report on the hemodynamics of the functional centrifugal-flow TAH with functional atrial contraction (fCFTAH). We evaluated the effects of pulsatile flow by atrial contraction in acute animal models. The goats received fCFTAH that we created from two centrifugal-flow ventricular assist devices. Some hemodynamic parameters maintained acceptable levels: heart rate 115.5 ± 26.3 bpm, aortic pressure 83.5 ± 10.1 mmHg, left atrial pressure 18.0 ± 5.9 mmHg, pulmonary pressure 28.5 ± 9.7 mmHg, right atrial pressure 13.6 ± 5.2 mmHg, pump flow 4.0 ± 1.1 L/min (left) 3.9 ± 1.1 L/min (right), and cardiac index 2.13 ± 0.14 L/min/m(2). fCFTAH with atrial contraction was able to maintain the TAH circulation by forming a pulsatile flow in acute animal experiments. Taking the left and right flow rate balance using the low internal pressure loss of the VAD pumps may be easier than by other pumps having considerable internal pressure loss. We showed that the remnant atrial contraction effected the flow rate change of the centrifugal pump, and the atrial contraction waves reflected the heart rate. These results indicate that remnant atria had the possibility to preserve autonomic function in fCFTAH. We may control fCFTAH by reflecting the autonomic function, which is estimated with the flow rate change of the centrifugal pump.

  4. [Mortality and life expectancy that attributable to high blood pressure in Chinese people in 2013].

    Science.gov (United States)

    Zeng, X Y; Liu, S W; Wang, L J; Zhang, M; Yin, P; Liu, Y N; Zhao, Z P; Wang, L M

    2017-08-10

    Objective: To estimate the deaths (mortality) and life expectancy that attributable to high blood pressure in people from different regions and gender, in China in 2013. Methods: Data was from the 'China Chronic Disease Risk Factor Surveillance 2013' and the 'China National Mortality Surveillance 2013'. According to the comparative risk assessment theory, population attributable fraction ( PAF ) of high blood pressure by gender, urban-rural, east-central-west regions was calculated before the estimations on deaths (mortality) and life expectancy attributable to high blood pressure was made. Results: In 2013, among the Chinese people aged 25 years old and above, the mean SBP was (129.48±20.27) mmHg. High blood pressure[SBP>(115±6) mmHg]caused 20.879 million deaths and accounted for 22.78% of the total deaths. SBP, deaths, mortality rate and standardized mortality rate that attributable to high blood pressure all appeared higher in men [(131.15±18.73) mmHg, 11.517 million, 165.56/100 000 and 106.97/100 000, respectively]than in women[(127.79±21.60) mmHg, 9.362 million, 141.99/100 000 and 68.93/100 000, respectively]. SBP, deaths, mortality rate and PAF were all seen higher in rural[(130.25±20.66) mmHg, 11.234 million, 178.58/100 000 and 23.59%, respectively]than in urban[(128.58±19.77) mmHg, 9.645 million, 132.87/100 000 and 21.54%, respectively]areas. However, levels of SBP were similar in the east, central or west regions, with attributable deaths, attributable mortality rate and PAF the highest as 7.658 million 179.93/100 000, and 26.72% respectively. In 2013, among the Chinese people aged 25 years old and above, deaths caused by cardiovascular disease and chronic kidney disease attributable to high blood pressure were 19.912 million and 0.966 million, accounting for 52.31% of the total deaths due to cardiovascular diseases and 62.11% to the total chronic kidney diseases. The top three deaths attributable to high blood pressure were ischemic heart disease (6

  5. The impact of parity on life course blood pressure trajectories: the HUNT study in Norway.

    Science.gov (United States)

    Haug, Eirin B; Horn, Julie; Markovitz, Amanda Rose; Fraser, Abigail; Macdonald-Wallis, Corrie; Tilling, Kate; Romundstad, Pål Richard; Rich-Edwards, Janet Wilson; Åsvold, Bjørn Olav

    2018-01-24

    The drop in blood pressure during pregnancy may persist postpartum, but the impact of pregnancy on blood pressure across the life course is not known. In this study we examined blood pressure trajectories for women in the years preceding and following pregnancy and compared life course trajectories of blood pressure for parous and nulliparous women. We linked information on all women who participated in the population-based, longitudinal HUNT Study, Norway with pregnancy information from the Medical Birth Registry of Norway. A total of 23,438 women were included with up to 3 blood pressure measurements per woman. Blood pressure trajectories were compared using a mixed effects linear spline model. Before first pregnancy, women who later gave birth had similar mean blood pressure to women who never gave birth. Women who delivered experienced a drop after their first birth of - 3.32 mmHg (95% CI, - 3.93, - 2.71) and - 1.98 mmHg (95% CI, - 2.43, - 1.53) in systolic and diastolic blood pressure, respectively. Subsequent pregnancies were associated with smaller reductions. These pregnancy-related reductions in blood pressure led to persistent differences in mean blood pressure, and at age 50, parous women still had lower systolic (- 1.93 mmHg; 95% CI, - 3.33, - 0.53) and diastolic (- 1.36 mmHg; 95% CI, - 2.26, - 0.46) blood pressure compared to nulliparous women. The findings suggest that the first pregnancy and, to a lesser extent, successive pregnancies are associated with lasting and clinically relevant reductions in systolic and diastolic blood pressure.

  6. Validation of the Oregon Scientific BPU 330 for self-monitoring of blood pressure according to the International Protocol

    Directory of Open Access Journals (Sweden)

    Li Li

    2008-10-01

    Full Text Available Li Li1, XinYu Zhang1, ChunHong Yan1, QingXiang Liang21Biomedical Engineering Lab, Faculty of Information Engineering, ShenZhen University, ShenZhen, China; 2Bao An People’s Hospital, ShenZhen, ChinaObjective: Extensive marketing of devices for self-measurement of blood pressure has created a need for purchasers to be able to satisfy themselves that such devices have been evaluated according to agreed criteria. The Oregon Scientific BPU 330 blood pressure monitor is an electronic device for upper arm measurement. This study assessed the accuracy of the Oregon Scientific BPU 330 blood pressure monitor according to the International Protocol by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension for validation of blood pressure measuring devices.Method: 52 participants over 30 years of age were studied in the validation. Nine blood pressure measurements were taken alternately with a mercury sphygmomanometer by two observers, and by the supervisor, using the BPU 330 device. A total of 33 participants were selected for the analysis. The validation was divided into two phases. Phase 1 included 15 participants. If the device passed phase 1, 18 more participants were included. The 99 pairs of measurements were compared according to the International Protocol. The device was given a pass/fail recommendation based on its accuracy compared with the mercury standard (within 5, 10, and 15 mmHg, as well as the number met in the ranges specified by the International Protocol.Results: The mean and standard deviation of the difference between the mean of the observers and the BPU 330 device were 1.7 ± 4.7 mmHg and 2.8 ± 3.9 mmHg for systolic blood pressure (SBP and diastolic blood pressure (DBP, respectively. In phase 1, the device passed with a total of 33, 43, and 44 SBP readings; 38, 44, and 45 DBP readings were within 5, 10, and 15 mmHg, respectively. In phase 2.1, 81, 95, and 96 for SBP, and 83, 95, and 98 for DBP

  7. Compression under a mechanical counter pressure space suit glove

    Science.gov (United States)

    Waldie, James M A.; Tanaka, Kunihiko; Tourbier, Dietmar; Webb, Paul; Jarvis, Christine W.; Hargens, Alan R.

    2002-01-01

    Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, pglove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

  8. Negative-Pressure Hydrocephalus: A Case Report on Successful Treatment Under Intracranial Pressure Monitoring with Bilateral Ventriculoperitoneal Shunts.

    Science.gov (United States)

    Pandey, Sajan; Jin, Yi; Gao, Liang; Zhou, Cheng Cheng; Cui, Da Ming

    2017-03-01

    Negative-pressure hydrocephalus (NegPH), a very rare condition of unknown etiology and optimal treatment, usually presents postneurosurgery with clinical and imaging features of hydrocephalus, but with negative cerebrospinal fluid pressure. We describe a NegPH case of -3 mm Hg intracranial pressure that was successfully treated to achieve 5 mm Hg under continuous intracranial pressure monitoring with horizontal positioning, head down and legs elevated to 10°-15°, neck wrapping for controlled venous drainage, chest and abdomen bandages, infusion of 5% dextrose fluid to lower plasma osmolarity (Na + , 130-135 mmol/L), daily cerebrospinal fluid drainage >200 mL, and arterial blood gas partial pressure of carbon dioxide >40 mm Hg. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  10. Different systolic blood pressure targets for people with history of stroke or transient ischaemic attack: PAST-BP (Prevention After Stroke—Blood Pressure) randomised controlled trial

    Science.gov (United States)

    McManus, Richard J; Roalfe, Andrea; Fletcher, Kate; Taylor, Clare J; Martin, Una; Virdee, Satnam; Greenfield, Sheila; Hobbs, F D Richard

    2016-01-01

    Objective To assess whether using intensive blood pressure targets leads to lower blood pressure in a community population of people with prevalent cerebrovascular disease. Design Open label randomised controlled trial. Setting 99 general practices in England, with participants recruited in 2009-11. Participants People with a history of stroke or transient ischaemic attack whose systolic blood pressure was 125 mm Hg or above. Interventions Intensive systolic blood pressure target (different target, patients in both arms were actively managed in the same way with regular reviews by the primary care team. Main outcome measure Change in systolic blood pressure between baseline and 12 months. Results 529 patients (mean age 72) were enrolled, 266 to the intensive target arm and 263 to the standard target arm, of whom 379 were included in the primary analysis (182 (68%) intensive arm; 197 (75%) standard arm). 84 patients withdrew from the study during the follow-up period (52 intensive arm; 32 standard arm). Mean systolic blood pressure dropped by 16.1 mm Hg to 127.4 mm Hg in the intensive target arm and by 12.8 mm Hg to 129.4 mm Hg in the standard arm (difference between groups 2.9 (95% confidence interval 0.2 to 5.7) mm Hg; P=0.03). Conclusions Aiming for target below 130 mm Hg rather than 140 mm Hg for systolic blood pressure in people with cerebrovascular disease in primary care led to a small additional reduction in blood pressure. Active management of systolic blood pressure in this population using a blood pressure. Trial registration Current Controlled Trials ISRCTN29062286. PMID:26919870

  11. An Investigation of Organic and Inorganic Mercury Exposure and Blood Pressure in a Small-Scale Gold Mining Community in Ghana.

    Science.gov (United States)

    Rajaee, Mozhgon; Sánchez, Brisa N; Renne, Elisha P; Basu, Niladri

    2015-08-21

    There is increasing concern about the cardiovascular effects of mercury (Hg) exposure, and that organic methylmercury and inorganic Hg(2+) may affect the cardiovascular system and blood pressure differentially. In small-scale gold mining communities where inorganic, elemental Hg exposures are high, little is known about the effects of Hg on blood pressure. In 2011, we assessed the relationship between Hg exposure and blood pressure (BP) in a cross-sectional study of adults from a small-scale gold mining community, Kejetia, and subsistence farming community, Gorogo, in Ghana's Upper East Region. Participants' resting heart rate and BP were measured, and hair and urine samples were provided to serve as biomarkers of organic and inorganic Hg exposure, respectively. Participants included 70 miners and 26 non-miners from Kejetia and 75 non-miners from Gorogo. Total specific gravity-adjusted urinary and hair Hg was higher among Kejetia miners than Kejetia non-miners and Gorogo participants (median urinary Hg: 5.17, 1.18, and 0.154 µg/L, respectively; hair Hg: 0.945, 0.419, and 0.181 µg/g, respectively). Hypertension was prevalent in 17.7% of Kejetia and 21.3% of Gorogo participants. Urinary and hair Hg were not significantly associated with systolic or diastolic BP for Kejetia or Gorogo participants while adjusting for sex, age, and smoking status. Although our results follow trends seen in other studies, the associations were not of statistical significance. Given the unique study population and high exposures to inorganic Hg, the work contained here will help increase our understanding of the cardiovascular effects of Hg.

  12. An Investigation of Organic and Inorganic Mercury Exposure and Blood Pressure in a Small-Scale Gold Mining Community in Ghana

    Science.gov (United States)

    Rajaee, Mozhgon; Sánchez, Brisa N.; Renne, Elisha P.; Basu, Niladri

    2015-01-01

    There is increasing concern about the cardiovascular effects of mercury (Hg) exposure, and that organic methylmercury and inorganic Hg2+ may affect the cardiovascular system and blood pressure differentially. In small-scale gold mining communities where inorganic, elemental Hg exposures are high, little is known about the effects of Hg on blood pressure. In 2011, we assessed the relationship between Hg exposure and blood pressure (BP) in a cross-sectional study of adults from a small-scale gold mining community, Kejetia, and subsistence farming community, Gorogo, in Ghana’s Upper East Region. Participants’ resting heart rate and BP were measured, and hair and urine samples were provided to serve as biomarkers of organic and inorganic Hg exposure, respectively. Participants included 70 miners and 26 non-miners from Kejetia and 75 non-miners from Gorogo. Total specific gravity-adjusted urinary and hair Hg was higher among Kejetia miners than Kejetia non-miners and Gorogo participants (median urinary Hg: 5.17, 1.18, and 0.154 µg/L, respectively; hair Hg: 0.945, 0.419, and 0.181 µg/g, respectively). Hypertension was prevalent in 17.7% of Kejetia and 21.3% of Gorogo participants. Urinary and hair Hg were not significantly associated with systolic or diastolic BP for Kejetia or Gorogo participants while adjusting for sex, age, and smoking status. Although our results follow trends seen in other studies, the associations were not of statistical significance. Given the unique study population and high exposures to inorganic Hg, the work contained here will help increase our understanding of the cardiovascular effects of Hg. PMID:26308023

  13. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  14. Prospective blood pressure measurement in renal transplant recipients.

    Science.gov (United States)

    David, V G; Yadav, B; Jeyaseelan, L; Deborah, M N; Jacob, S; Alexander, S; Varughese, S; John, G T

    2014-05-01

    Blood pressure (BP) control at home is difficult when managed only with office blood pressure monitoring (OBPM). In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM) was compared with ambulatory blood pressure monitoring (ABPM) as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2(nd), 4(th), 6(th), and 9(th) months and all the three methods: OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%). Systolic BP (SBP) and diastolic BP (DBP) measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa: 0.88 vs. 89% specificity, Kappa: 0.71). HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa: 0.71 vs. 50% specificity Kappa: 0.54). In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  15. Prospective blood pressure measurement in renal transplant recipients

    Directory of Open Access Journals (Sweden)

    V G David

    2014-01-01

    Full Text Available Blood pressure (BP control at home is difficult when managed only with office blood pressure monitoring (OBPM. In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM was compared with ambulatory blood pressure monitoring (ABPM as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2 nd , 4 th , 6 th , and 9 th months and all the three methods : OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%. Systolic BP (SBP and diastolic BP (DBP measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa : 0.88 vs. 89% specificity, Kappa : 0.71. HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa : 0.71 vs. 50% specificity Kappa : 0.54. In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  16. Long-distance transport of Hg, Sb, and As from a mined area, conversion of Hg to methyl-Hg, and uptake of Hg by fish on the Tiber River basin, west-central Italy

    Science.gov (United States)

    Gray, John E.; Rimondi, Valentina; Costagliola, Pilario; Vaselli, Orlando; Lattanzi, Pierfranco

    2014-01-01

    Stream sediment, stream water, and fish were collected from a broad region to evaluate downstream transport and dispersion of mercury (Hg) from inactive mines in the Monte Amiata Hg District (MAMD), Tuscany, Italy. Stream sediment samples ranged in Hg concentration from 20 to 1,900 ng/g, and only 5 of the 17 collected samples exceeded the probable effect concentration for Hg of 1,060 ng/g, above which harmful effects are likely to be observed in sediment-dwelling organisms. Concentrations of methyl-Hg in Tiber River sediment varied from 0.12 to 0.52 ng/g, and although there is no established guideline for sediment methyl-Hg, these concentrations exceeded methyl-Hg in a regional baseline site (water varied from 1.2 to 320 ng/L, all of which were below the 1,000 ng/L Italian drinking water Hg guideline and the 770 ng/L U.S. Environmental Protection Agency (USEPA) guideline recommended to protect against chronic effects to aquatic wildlife. Methyl-Hg concentrations in stream water varied from water samples contained concentrations of As (drinking water guidelines to protect human health (10 μg/L for As and 20 μg/L for Sb) and for protection against chronic effects to aquatic wildlife (150 μg/L for As and 5.6 μg/L for Sb). Concentrations of Hg in freshwater fish muscle ranged from 0.052–0.56 μg/g (wet weight), mean of 0.17 μg/g, but only 17 % (9 of 54) exceeded the 0.30 μg/g (wet weight) USEPA fish muscle guideline recommended to protect human health. Concentrations of Hg in freshwater fish in this region generally decreased with increasing distance from the MAMD, where fish with the highest Hg concentrations were collected more proximal to the MAMD, whereas all fish collected most distal from Hg mines contained Hg below the 0.30 μg/g fish muscle guideline. Data in this study indicate some conversion of inorganic Hg to methyl-Hg and uptake of Hg in fish on the Paglia River, but less methylation of Hg and Hg uptake by freshwater fish in the larger Tiber River.

  17. Positive gain measurements on the 3350-A continuum band of Hg2

    International Nuclear Information System (INIS)

    Schlie, L.A.; Guenther, B.D.; Rathge, R.D.

    1976-01-01

    A He-Cd + laser operating at 3250 A and an Ar + laser at 3511 A and 3638 A have been used to probe for gain on both sides of the Hg 2 3350-A (A 3 1/subu/→X 1 Σ/subg/ + ) continuum band in Hg vapor at a pressure of 3.75 atm that was pumped by a 1.5-MeV 600-J 20-ns electron beam. This letter presents the first observation of positive gain on this 3350-A band of Hg 2 . The results indicate that the stimulated emission cross section for this band is larger than any associated photoionization process in the Hg vapor and has a magnitude of approximately 10 -18 cm 2 . Also, raising the temperature of the vapor above its saturation value increases the maximum value and duration of the observed gain, indicating that the population of the upper level of this transition is being fed by a temperature-dependent internal energy reservoir in the Hg

  18. Validation of the blood pressure measurement device Erkameter 125 PRO according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Beime, Beate; Deutsch, Cornelia; Krüger, Ralf; Zimmermann, Erik; Bramlage, Peter

    2016-12-01

    The aim of the present study was to validate the blood pressure (BP) measurement device Erkameter 125 PRO according to the International Protocol revision 2010 of the European Society of Hypertension (ESH-IP2). In 33 patients aged 32-79 years, BP measurements were performed alternately using the Erkameter 125 PRO and the reference mercury sphygmomanometer according to ESH-IP revision 2010. For the analysis, a total of 99 comparisons were included. All absolute differences between the test device and the reference were within 10 mmHg for systolic blood pressure (SBP), and all except one for diastolic blood pressure (DBP). A total of 93 out of 99 comparisons for SBP showed an absolute difference within 5 mmHg and 92 out of 99 for DBP. The mean±SD difference between the Erkameter 125 PRO and the standard reference was -0.5±3.5 mmHg for SBP and 0.5±3.5 mmHg for DBP. As to part 2 of ESH-IP 2010, all patients had a minimum of two out of three measurements within 5 mmHg difference for SBP and 31 out of 33 patients for DBP. The Erkameter 125 PRO fulfilled the requirements of parts 1 and 2 of the ESH-IP revision 2010 and can be recommended for office BP measurements in adults.

  19. Effects of turning on skin-bed interface pressures in healthy adults.

    Science.gov (United States)

    Peterson, Matthew J; Schwab, Wilhelm; van Oostrom, Johannes H; Gravenstein, Nikolaus; Caruso, Lawrence J

    2010-07-01

    This paper is a report of a study of the effects of lateral turning on skin-bed interface pressures in the sacral, trochanteric and buttock regions, and its effectiveness in unloading at-risk tissue. Minimizing skin-support surface interface pressure is important in pressure ulcer prevention, but the effect of standard patient repositioning on skin interface pressure has not been objectively established. Data were collected from 15 healthy adults from a university-affiliated hospital. Mapped 24-inch x 24-inch (2304 half-inch sensors) interface pressure profiles were obtained in the supine position, followed by lateral turning with pillow or wedge support and subsequent head-of-bed elevation to 30 degrees . Raising the head-of-bed to 30 degrees in the lateral position statistically significantly increased peak interface pressures and total area > or = 32 mmHg. Comparing areas > or = 32 mmHg from all positions, 93% of participants had skin areas with interface pressures > or = 32 mmHg throughout all positions (60 +/- 54 cm(2)), termed 'triple jeopardy areas'. The triple jeopardy area increased statistically significantly with wedges as compared to pillows (153 +/- 99 cm(2) vs. 48 +/- 47 cm(2), P turning by experienced intensive care unit nurses does not reliably unload all areas of high skin-bed interface pressures. These areas remain at risk for skin breakdown, and help to explain why pressure ulcers occur despite the implementation of standard preventive measures. Support materials for maintaining lateral turned positions can also influence tissue unloading and triple jeopardy areas.

  20. Correlation of Noninvasive Blood Pressure and Invasive Intra-arterial Blood Pressure in Patients Treated with Vasoactive Medications in a Neurocritical Care Unit.

    Science.gov (United States)

    Saherwala, Ali A; Stutzman, Sonja E; Osman, Mohamed; Kalia, Junaid; Figueroa, Stephen A; Olson, DaiWai M; Aiyagari, Venkatesh

    2018-03-22

    The correlation between noninvasive (oscillometric) blood pressure (NBP) and intra-arterial blood pressure (IAP) in critically ill patients receiving vasoactive medications in a Neurocritical Care Unit has not been systematically studied. The purpose of this study is to examine the relationship between simultaneously measured NBP and IAP recordings in these patients. Prospective observational study of patients (N = 70) admitted to a neurocritical care unit receiving continuous vasopressor or antihypertensive infusions. Paired NBP/IAP observations along with covariate and demographic data were abstracted via chart audit. Analysis was performed using SAS v9.4. A total of 2177 paired NBP/IAP observations from 70 subjects (49% male, 63% white, mean age 59 years) receiving vasopressors (n = 21) or antihypertensive agents (n = 49) were collected. Paired t test analysis showed significant differences between NBP versus IAP readings: ([systolic blood pressure (SBP): mean = 136 vs. 140 mmHg; p blood pressure (DBP): mean = 70 vs. 68 mmHg, p blood pressure (MAP): mean = 86 vs. 90 mmHg, p blood pressures. Pearson correlation coefficients show strong positive correlations for paired MAP (r = 0.82), SBP (r = 0.84), and DBP (r = 0.73) recordings. An absolute NBP-IAP SBP difference of > 20 mmHg was seen in ~ 20% of observations of nicardipine, ~ 25% of observations of norepinephrine, and ~ 35% of observations of phenylephrine. For MAP, the corresponding numbers were ~ 10, 15, and 25% for nicardipine, norepinephrine, and phenylephrine, respectively. Despite overall strong positive correlations between paired NBP and IAP readings of MAP and SBP, clinically relevant differences in blood pressure are frequent. When treating with vasoactive infusions targeted to a specific BP goal, it is important to keep in mind that NBP and IAP values are not interchangeable.

  1. Binding of Hg by bacterial extracellular polysaccharide: a possible role in Hg tolerance.

    Science.gov (United States)

    Cruz, Kimberly; Guézennec, Jean; Barkay, Tamar

    2017-07-01

    Bacteria employ adaptive mechanisms of mercury (Hg) tolerance to survive in environments containing elevated Hg concentrations. The potential of extracellular polysaccharides (EPS) production by bacteria as a mechanism of Hg tolerance has not been previously investigated. The objectives of this study were to determine if bacterial EPS sorb Hg, and if so does sorption provide protection against Hg toxicity. Purified EPS with different chemical compositions produced by bacterial isolates from microbial mats in French Polynesian atolls and deep-sea hydrothermal vents were assessed for Hg sorption. The data showed that EPS sorbed up to 82% of Hg from solution, that this sorption was dependent on EPS composition, and that sorption was a saturable mechanism. Hg uptake capacities ranged from 0.005 to 0.454 mmol Hg/g for the different EPS. To determine if EPS production could alter bacterial Hg tolerance, Escherichia coli K-12 strains and their EPS defective mutants were tested by the disc inhibition assay. Mercury inhibited growth in a dose-dependent manner with wild-type strains having smaller (~1 mm), but statistically significant, zones of inhibition than various mutants and this difference was related to a 2-fold decline in the amount of EPS produced by the mutants relative to cell biomass. These experiments identified colanic acid and hexosamine as Hg-binding moieties in EPS. Together these data indicate that binding of Hg to EPS affords a low level of resistance to the producing bacteria.

  2. Home readings of blood pressure in assessment of hypertensive subjects

    DEFF Research Database (Denmark)

    Nielsen, P.E.; Myschetzky, P; Andersen, A R

    1986-01-01

    Out-patient clinic blood pressure (OPC-BP) was compared to home blood pressure (Home-BP) measured three times daily during a two week period in 122 consecutively referred hypertensive subjects. A semi-automatic device (TM-101) including a microphone for detection of Korotkoff-sounds, self......-deflation of cuff pressure and digital display of blood pressure was used. Mean difference between OPC-BP and Home-BP was systolic +13 mm Hg (range -21 - +100 mg Hg) and diastolic +5 mm Hg (range -27 - +36 mm Hg). Although a significant correlation could be demonstrated between Home-BP and OPC-BP, the inter...

  3. Treating a 20 mm Hg gradient alleviates myocardial hypertrophy in experimental aortic coarctation.

    Science.gov (United States)

    Wendell, David C; Friehs, Ingeborg; Samyn, Margaret M; Harmann, Leanne M; LaDisa, John F

    2017-10-01

    Children with coarctation of the aorta (CoA) can have a hyperdynamic and remodeled left ventricle (LV) from increased afterload. Literature from an experimental model suggests the putative 20 mm Hg blood pressure gradient (BPG) treatment guideline frequently implemented in CoA studies may permit irreversible vascular changes. LV remodeling from pressure overload has been studied, but data are limited following correction and using a clinically representative BPG. Rabbits underwent CoA at 10 weeks to induce a 20 mm Hg BPG using permanent or dissolvable suture thereby replicating untreated and corrected CoA, respectively. Cardiac function was evaluated at 32 weeks by magnetic resonance imaging using a spoiled cine GRE sequence (TR/TE/FA 8/2.9/20), 14 × 14-cm FOV, and 3-mm slice thickness. Images (20 frames/cycle) were acquired in 6-8 short axis views from the apex to the mitral valve annulus. LV volume, ejection fraction (EF), and mass were quantified. LV mass was elevated for CoA (5.2 ± 0.55 g) versus control (3.6 ± 0.16 g) and corrected (4.0 ± 0.44 g) rabbits, resulting in increased LV mass/volume ratio for CoA rabbits. A trend toward increased EF and stroke volume was observed but did not reach significance. Elevated EF by volumetric analysis in CoA rabbits was supported by concomitant increases in total aortic flow by phase-contrast magnetic resonance imaging. The indices quantified trended toward a persistent hyperdynamic LV despite correction, but differences were not statistically significant versus control rabbits. These findings suggest the current putative 20 mm Hg BPG for treatment may be reasonable from the LV's perspective. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Speciation of Hg in lichens

    International Nuclear Information System (INIS)

    Jereb, Vesna; Horvat, Milena

    2002-01-01

    Lichens have long been regarded as a suitable tool for monitoring the relative levels of atmospheric pollutants. Lichens have neither roots, a waxy cuticle nor stomata: hence, for mineral nutrition they are largely dependent on wet and dry deposition from the atmosphere. Moreover, lichens are perennial and can accumulate elements over long periods of time. Therefore, concentrations of elements in lichens represent the average levels of elements in the atmosphere for a long period of time. The epiphytic lichen Hypogymnia physodes is a good bioindicator of air pollution with total mercury (THg). In addition, it contains small amounts of methylmercury (MeHg + ). The first aim of our work was to test analytical techniques for determination of MeHg in lichens taken from different locations in Idrija and reference locations

  5. Extended x-ray absorption fine structure study of arsenic in HgCdTe: p-type doping linked to nonsubstitutional As incorporation in an unknown AsHg8 structure

    International Nuclear Information System (INIS)

    Biquard, X.; Alliot, I.; Ballet, P.

    2009-01-01

    An extended x-ray absorption fine structure (EXAFS) investigation has been carried out on arsenic-doped Hg 70 Cd 30 Te samples. The incorporation of atomic arsenic has been achieved using a nonconventional radio-frequency plasma source in a molecular beam epitaxy reactor. Two samples from the same epitaxial wafer have been studied. One underwent a 400 deg. C activation annealing under Hg pressure, leading to n to p-type conversion. In the commonly admitted scenario, this conversion is associated with the annealing-induced migration of As from a Hg site to a Te site. This study shows that this is not the case. Before annealing, As is found to be involved in noncrystalline structures: 50% inside an As 2 Te 3 chalcogenide glass and 50% inside a new AsHg 8 compact structure. After annealing, the As 2 Te 3 chalcogenide glass disappears, 31% of As occupies Hg sites and 69% incorporates inside this new AsHg 8 compact structure that occupies Te sites. The EXAFS results are in excellent agreement with 77 K Hall-effect measurements. The new AsHg 8 structure is found to have an acceptor behavior. Overall, this study provides an entirely new vision of extrinsic p-type doping of HgCdTe as well as the first experimental evidence of As site transfer induced by annealing.

  6. Benchtop evaluation of pressure barrier insufflator and standard insufflator systems.

    Science.gov (United States)

    Nepple, Kenneth G; Kallogjeri, Dorina; Bhayani, Sam B

    2013-01-01

    Previous experimental research has reported minimal differences in pressure maintenance between different versions of standard insufflators (SI). However, a recent report identified potential clinical benefits with a valveless pressure barrier insufflator (PBI). We sought to perform a benchtop objective evaluation of SI and PBI systems. A rigid box system with continuous pressure manometry was used to evaluate a PBI (Surgiquest Airseal) and two SIs (SI1 = Stryker PneumoSure High Flow Insufflator and SI2 = Storz SCB Thermoflator). Pressure maintenance of 15 mmHg was evaluated during experimental conditions of leakage from a 5 mm port site, leakage from a 12 mm port site, and continuous suction. With leakage from the 5 mm port site, the PBI maintained pressure of >13 mmHg whereas the pressures dropped moderately with the SI1 (7-13 mmHg) and SI2 insufflators (3-7 mmHg) and did not regain goal pressure until leakage was stopped. With leakage from 12 mm port site, the PBI pressure decreased to 9-11 mmHg, whereas the SI1 and SI2 lost insufflation pressures completely. The PBI maintained pressure of >11 mmHg during continuous suction while the SI1 and SI2 lost pressure entirely, and actually showed negative pressure from air suction into the rigid box system. When evaluated statistically with the mixed model repeated measures ANOVA, the SI1 and SI2 performed similarly while the PBI maintained increased pressure. In the experimental rigid box system, the PBI more successfully maintained pressure in response to leakage and suction than SIs.

  7. PRESENCIA DEL HG TOTAL EN UNA RELACIÓN SUELO-PLANTA-ATMÓSFERA AL SUR DE LA SIERRA GORDA DE QUERÉTARO, MÉXICO

    Directory of Open Access Journals (Sweden)

    Gilberto Hernández-Silva

    2012-01-01

    Full Text Available La región minera de San Joaquín, Querétaro, México, tiene un historial de más de dos mil años de explotación. En ella se identificaron cuatro áreas con contenidos de Hg en suelos por arriba de lo permitido por la NOM y la WHO: Azogues y Ranas- San Joaquín (>300 mg kg-1 y Calabacillas-Santa Rita y La Lana (30.1-300 mg kg-1. Los suelos de estas áreas proporcionan al maíz (Zea mays, cantidades significativas de Hg total a través de mecanismos de traslocación (0.2-8.7 mg kg-1 en raíces y 0.2- 8.2 mg kg-1 en tallo y hoja; en grano, las cantidades oscilan entre 0.04-0.87 mg kg-1 (0.5 mg kg-1 es el máximo permitido. En la fracción insoluble del agua de lluvia, la concentración promedio fue de 67.47 μg L-1; en la fracción soluble se tuvo un promedio de 36.49 μg L-1. El promedio diario de vapor de Hg fue de 67 ng m-3 durante los 38 días de lectura, con un intervalo de 40 a 100 ng m-3, lo que demuestra una gran diferencia en la cantidad de volatilización del Hg. Los suelos, sedimentos y terreros de cinabrio, constituyen la fuente que provee de Hg al maíz a través de mecanismos de traslocación y material particulado hacia la atmósfera arrastrado por el viento y redepositado a sotavento. Las lecturas que se obtuvieron de vapor de Hg resultaron más altas de lo recomendable. Los resultados obtenidos en el sistema estudiado, denotan concentraciones por arriba del límite permisible. La población de San Joaquín está expuesta a una concentración de mercurio que es variable y por arriba de lo permitido, lo que puede tener serias consecuencias en la salud humana y el posible impacto en el medio ambiente.

  8. Use of L-cysteine for minimization of inorganic Hg loss during thermal neutron irradiation

    International Nuclear Information System (INIS)

    Anderson, D.L.

    2009-01-01

    Thermal neutron irradiation experiments performed with cellulose-based L-cysteine-treated and untreated Hg standards showed Hg losses of 59-81% for untreated standards but only about a 0.2% loss for treated standards. These results and others for multielement standards showed that Hg loss is highly dependent on total mass and placement of materials in the irradiation vessel and that distribution of volatilized Hg was fairly uniform throughout the sample-containing region of the vessel. Polyethylene trapped volatile Hg much more efficiently than cellulose and a multielement standard containing inorganic Se selectively trapped Hg lost from a co-irradiated multielement standard containing Hg. (author)

  9. The Age-Dependent Relationship between Blood Pressure and Cognitive Impairment: A Cross-Sectional Study in a Rural Area of Xi'an, China.

    Science.gov (United States)

    Shang, Suhang; Li, Pei; Deng, Meiying; Jiang, Yu; Chen, Chen; Qu, Qiumin

    2016-01-01

    Hypertension is a modifiable risk factor for cognitive impairment, although the relationship between hypertension and cognitive impairment is not fully understood. The objective of this study was to investigate the effect of age on the relationship between blood pressure and cognitive impairment. Blood pressure and global cognitive function information was collected from 1799 participants (age 40-85) who lived in a village in the suburbs of Xi'an, China, during in-person interviews. Cognitive impairment was defined as a Mini-Mental State Examination (MMSE) score lower than the cutoff value. The effect of age on the relationship between blood pressure parameters [systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial blood pressure (MABP), and high blood pressure (HBP, SBP≥140 mm Hg and/or DBP≥90 mm Hg)] and cognitive impairment was analyzed by logistic regression models using interaction and stratified analysis. Blood pressure and age were regarded as both continuous and categorical data. A total of 231 participants were diagnosed as having cognitive impairment based on our criteria. Interaction analysis for the total population showed that SBP (when regarded as continuous data) was positively correlated with cognitive impairment (OR = 1.130 [95% CI, 1.028-1.242] per 10mmHg, P = 0.011); however, the age by SBP interaction term was negatively correlated with cognitive impairment (OR = 0.989 [95% CI, 0.982-0.997] per 10mmHg×year, P = 0.006), indicating that the relationship between SBP and cognitive impairment was age-dependent (OR = 1.130×0.989(age-55.5) per 10mmHg,40 ≤age≤85). When the blood pressure and age were considered as binary data, the results were similar to those obtained when they were considered as continuous variables. Stratified multivariate analysis revealed that the relationship between SBP (when regarded as continuous data) and cognitive impairment was positive for patients aged 40-49 years (OR = 1.349 [95% CI: 1

  10. Evaluating the risk of eye injuries: intraocular pressure during high speed projectile impacts.

    Science.gov (United States)

    Duma, Stefan M; Bisplinghoff, Jill A; Senge, Danielle M; McNally, Craig; Alphonse, Vanessa D

    2012-01-01

    To evaluate the risk of eye injuries by determining intraocular pressure during high speed projectile impacts. A pneumatic cannon was used to impact eyes with a variety of projectiles at multiple velocities. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve. A total of 36 tests were performed on 12 porcine eyes with a range of velocities between 6.2 m/s and 66.5 m/s. Projectiles selected for the test series included a 6.35  mm diameter metal ball, a 9.25  mm diameter aluminum rod, and an 11.16  mm diameter aluminum rod. Experiments were designed with velocities in the range of projectile consumer products such as toy guns. A range of intraocular pressures ranged between 2017 mmHg to 26,426 mmHg (39 psi-511 psi). Four of the 36 impacts resulted in globe rupture. Intraocular pressures dramatically above normal physiological pressure were observed for high speed projectile impacts. These pressure data provide critical insight to chronic ocular injuries and long-term complications such as glaucoma and cataracts.

  11. An Investigation of Organic and Inorganic Mercury Exposure and Blood Pressure in a Small-Scale Gold Mining Community in Ghana

    Directory of Open Access Journals (Sweden)

    Mozhgon Rajaee

    2015-08-01

    Full Text Available There is increasing concern about the cardiovascular effects of mercury (Hg exposure, and that organic methylmercury and inorganic Hg2+ may affect the cardiovascular system and blood pressure differentially. In small-scale gold mining communities where inorganic, elemental Hg exposures are high, little is known about the effects of Hg on blood pressure. In 2011, we assessed the relationship between Hg exposure and blood pressure (BP in a cross-sectional study of adults from a small-scale gold mining community, Kejetia, and subsistence farming community, Gorogo, in Ghana’s Upper East Region. Participants’ resting heart rate and BP were measured, and hair and urine samples were provided to serve as biomarkers of organic and inorganic Hg exposure, respectively. Participants included 70 miners and 26 non-miners from Kejetia and 75 non-miners from Gorogo. Total specific gravity-adjusted urinary and hair Hg was higher among Kejetia miners than Kejetia non-miners and Gorogo participants (median urinary Hg: 5.17, 1.18, and 0.154 µg/L, respectively; hair Hg: 0.945, 0.419, and 0.181 µg/g, respectively. Hypertension was prevalent in 17.7% of Kejetia and 21.3% of Gorogo participants. Urinary and hair Hg were not significantly associated with systolic or diastolic BP for Kejetia or Gorogo participants while adjusting for sex, age, and smoking status. Although our results follow trends seen in other studies, the associations were not of statistical significance. Given the unique study population and high exposures to inorganic Hg, the work contained here will help increase our understanding of the cardiovascular effects of Hg.

  12. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  13. A Neutron Scattering Study of Lattice Dynamics of HgTe and HgSe

    DEFF Research Database (Denmark)

    Kepa, H.; Giebultowicz, T.; Buras, B.

    1982-01-01

    The dispersion relations for the acoustic and optic phonons in HgTe and for the acoustic phonons in HgSe were determined by neutron inelastic scattering in three high symmetry directions. The effect of the free-carrier screening of the long-range electric field of LO phonons in HgTe was observed....... The formalism of the rigid ion model is used for numerical calculations of the phonon dispersion relations and the phonon densities of states in HgTe and HgSe....

  14. Fifty shades of gradients: does the pressure gradient in venous sinus stenting for idiopathic intracranial hypertension matter? A systematic review.

    Science.gov (United States)

    McDougall, Cameron M; Ban, Vin Shen; Beecher, Jeffrey; Pride, Lee; Welch, Babu G

    2018-03-02

    OBJECTIVE The role of venous sinus stenting (VSS) for idiopathic intracranial hypertension (IIH) is not well understood. The aim of this systematic review is to attempt to identify subsets of patients with IIH who will benefit from VSS based on the pressure gradients of their venous sinus stenosis. METHODS MEDLINE/PubMed was searched for studies reporting venous pressure gradients across the stenotic segment of the venous sinus, pre- and post-stent pressure gradients, and clinical outcomes after VSS. Findings are reported according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. RESULTS From 32 eligible studies, a total of 186 patients were included in the analysis. Patients who had favorable outcomes had higher mean pressure gradients (22.8 ± 11.5 mm Hg vs 17.4 ± 8.0 mm Hg, p = 0.033) and higher changes in pressure gradients after stent placement (19.4 ± 10.0 mm Hg vs 12.0 ± 6.0 mm Hg, p = 0.006) compared with those with unfavorable outcomes. The post-stent pressure gradients between the 2 groups were not significantly different (2.8 ± 4.0 mm Hg vs 2.7 ± 2.0 mm Hg, p = 0.934). In a multivariate stepwise logistic regression controlling for age, sex, body mass index, CSF opening pressure, pre-stent pressure gradient, and post-stent pressure gradient, the change in pressure gradient with stent placement was found to be an independent predictor of favorable outcome (p = 0.028). Using a pressure gradient of 21 as a cutoff, 81/86 (94.2%) of patients with a gradient > 21 achieved favorable outcomes, compared with 82/100 (82.0%) of patients with a gradient ≤ 21 (p = 0.022). CONCLUSIONS There appears to be a relationship between the pressure gradient of venous sinus stenosis and the success of VSS in IIH. A randomized controlled trial would help elucidate this relationship and potentially guide patient selection.

  15. Microbial Oxidation of Hg(0) - Its Effect on Hg Stable Isotope Fractionation and Methylmercury Production

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Nathan [Rutgers Univ., New Brunswick, NJ (United States); Barkay, Tamar [Rutgers Univ., New Brunswick, NJ (United States); Reinfelder, John [Rutgers Univ., New Brunswick, NJ (United States)

    2016-06-28

    Mercury (Hg) associated with mixed waste generated by nuclear weapons manufacturing has contaminated vast areas of the Oak Ridge Reservation (ORR). Neurotoxic methylmercury (MeHg) has been formed from the inorganic Hg wastes discharged into headwaters of East Fork Poplar Creek (EFPC). Thus, understanding the processes and mechanisms that lead to Hg methylation along the flow path of EFPC is critical to predicting the impacts of the contamination and the design of remedial action at the ORR. In part I of our project, we investigated Hg(0) oxidation and methylation by anaerobic bacteria. We discovered that the anaerobic bacterium Desulfovibrio desulfuricans ND132 can oxidize elemental mercury [Hg(0)]. When provided with dissolved elemental mercury, D. desulfuricans ND132 converts Hg(0) to Hg(II) and neurotoxic methylmercury [MeHg]. We also demonstrated that diverse species of subsurface bacteria oxidizes dissolved elemental mercury under anoxic conditions. The obligate anaerobic bacterium Geothrix fermentans H5, and the facultative anaerobic bacteria Shewanella oneidensis MR-1 and Cupriavidus metallidurans AE104 can oxidize Hg(0) to Hg(II) under anaerobic conditions. In part II of our project, we established anaerobic enrichment cultures and obtained new bacterial strains from the DOE Oak Ridge site. We isolated three new bacterial strains from subsurface sediments collected from Oak Ridge. These isolates are Bradyrhizobium sp. strain FRC01, Clostridium sp. strain FGH, and a novel Negativicutes strain RU4. Strain RU4 is a completely new genus and species of bacteria. We also demonstrated that syntrophic interactions between fermentative bacteria and sulfate-reducing bacteria in Oak Ridge saprolite mediate iron reduction via multiple mechanisms. Finally, we tested the impact of Hg on denitrification in nitrate reducing enrichment cultures derived from subsurface sediments from the Oak Ridge site, where nitrate is a major contaminant. We showed that there is an inverse

  16. Tracing historical trends of Hg in the Mississippi River using Hg concentrations and Hg isotopic compositions in a lake sediment core, Lake Whittington, Mississippi, USA

    Science.gov (United States)

    Gray, John E.; Van Metre, Peter C.; Pribil, Michael J.; Horowitz, Arthur J.

    2015-01-01

    Concentrations and isotopic compositions of mercury (Hg) in a sediment core collected from Lake Whittington, an oxbow lake on the Lower Mississippi River, were used to evaluate historical sources of Hg in the Mississippi River basin. Sediment Hg concentrations in the Lake Whittington core have a large 10-15 y peak centered on the 1960s, with a maximum enrichment factor relative to Hg in the core of 4.8 in 1966. The Hg concentration profile indicates a different Hg source history than seen in most historical reconstructions of Hg loading. The timing of the peak is consistent with large releases of Hg from Oak Ridge National Laboratory (ORNL), primarily in the late 1950s and 1960s. Mercury was used in a lithiumisotope separation process by ORNL and an estimated 128Mg (megagrams) of Hgwas discharged to a local stream that flows into the Tennessee River and, eventually, the Mississippi River. Mass balance analyses of Hg concentrations and isotopic compositions in the Lake Whittington core fit a binary mixing model with a Hg-rich upstream source contributing about 70% of the Hg to Lake Whittington at the height of the Hg peak in 1966. This upstream Hg source is isotopically similar to Hg isotope compositions of stream sediment collected downstream near ORNL. It is estimated that about one-half of the Hg released from the ORNL potentially reached the LowerMississippi River basin in the 1960s, suggesting considerable downstream transport of Hg. It is also possible that upstream urban and industrial sources contributed some proportion of Hg to Lake Whittington in the 1960s and 1970s.

  17. Electron beam induced Hg desorption and the electronic structure of the Hg depleted surface of Hg1/sub -//sub x/Cd/sub x/Te

    International Nuclear Information System (INIS)

    Shih, C.K.; Friedman, D.J.; Bertness, K.A.; Lindau, I.; Spicer, W.E.; Wilson, J.A.

    1986-01-01

    Auger electron spectroscopy (AES), x-ray photoemission spectroscopy (XPS), low energy electron diffraction (LEED), and angle-resolved ultraviolet photoemission spectroscopy (ARPES) were used to study the electron beam induced Hg desorption from a cleaved (110)Hg/sub 1-//sub x/Cd/sub x/Te surface and the electronic structure of the Hg depleted surface. Solid state recrystallized Hg/sub 1-//sub x/Cd/sub x/Te single crystals were used. It was found that the electron beam heating dominated the electron beam induced Hg desorption on Hg/sub 1-//sub x/Cd/sub x/Te. At the electron beam energy used, the electron beam heating extended several thousand angstroms deep. However, the Hg depletion saturated after a few monolayers were depleted of Hg atoms. At the initial stage of Hg loss (only 3%), the surface band bends upward (more p type). The ARPES spectrum showed the loss of some E vs k dispersion after 22% Hg atoms were removed from the surface region, and no dispersion was observed after 43% Hg atoms were removed. These results have important implications on the electronic structure of the surfaces and interfaces of which the stoichiometry is altered

  18. Superconductivity of Hg3NbF6 and Hg3TaF6

    International Nuclear Information System (INIS)

    Datars, W.R.; Morgan, K.R.; Gillespie, R.J.

    1983-01-01

    Low-temperature ac susceptibility measurements show that two new metallic compounds, Hg 3 TaF 6 and Hg 3 NbF 6 , are superconductors with a critical temperature of 7.0 K. Critical fields are 20% higher in Hg 3 TaF 6 but the temperature dependence of the critical field of the compounds is very similar down to 1.35 K. The critical field extrapolated to T = 0 K is 0.17 T for Hg 3 TaF 6 and 0.13 T for Hg 3 NbF 6

  19. The efficacy and safety of a proprietary onion-pumpkin extract (OPtain120 on blood pressure: an open-label study

    Directory of Open Access Journals (Sweden)

    Orie Yoshinari

    2015-06-01

    Full Text Available Background: Nutraceuticals and functional foods are increasingly being used to help manage hypertension. Treatment with either pumpkin or onion can significantly lower systolic and diastolic blood pressure in animal studies. Traditionally, pumpkin has been used to support healthy blood pressure, glucose tolerance and lipid levels. Onion contains high levels of flavonoids, including quercetin, which decreases blood pressure and promotes restoration of healthy endothelial function. However, human trials on these food sources are limited, and the combined effects of pumpkin and onion have not been examined yet. Objective: We performed an open-label clinical study to evaluate the effects of a proprietary onion-pumpkin extract (OPtain120 on systolic and diastolic blood pressure. Methods: Healthy adults with systolic blood pressure (SBP and diastolic blood pressure (DBP in the elevated range of 140-159 and 80-90 mmHg, respectively, were enrolled in this study. Subjects consumed one capsule of onion-pumpkin extract twice daily for 12 weeks. Daily Home Blood Pressure Measurement (HBPM was taken upon waking and before bed. Office Blood Pressure Measurement (OBPM was taken in-clinic at Week 0, 6, and 12. Results: 52 subjects were screened and 12 were enrolled in the study, with a total of 10 subjects completing the study. Systolic HBPM taken before bed demonstrated a statistically significant reduction from baseline (147.23 mmHg to Week 12 (138.14 mmHg, representing a reduction of 9.09 mmHg (6.17%, p=0.021. Diastolic HBPM taken before bed demonstrated a decrease of 4.06 mmHg (4.46%, p=0.085, a significant reduction from baseline (91.07 mmHg at Week 12 (87.02 mmHg. Non-statistically significant reductions were seen in the early morning Systolic (3.14% and Diastolic (2.57% HBPM and in the Systolic (1.36% OBPM. Conclusion: OPtain120 was safely consumed over a 12-week period. OPtain120 appears to be effective in lowering Systolic Blood Pressure at bedtime in

  20. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1989-08-15

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction.

  1. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    International Nuclear Information System (INIS)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup

    1989-01-01

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction

  2. Vapor pressure and vapor fractionation of silicate melts of tektite composition

    Science.gov (United States)

    Walter, Louis S.; Carron, M.K.

    1964-01-01

    The total vapor pressure of Philippine tektite melts of approximately 70 per cent silica has been determined at temperatures ranging from 1500 to 2100??C. This pressure is 190 ?? 40 mm Hg at 1500??C, 450 ?? 50 mm at 1800??C and 850 ?? 70 mm at 2100?? C. Determinations were made by visually observing the temperature at which bubbles began to form at a constant low ambient pressure. By varying the ambient pressure, a boiling point curve was constructed. This curve differs from the equilibrium vapor pressure curve due to surface tension effects. This difference was evaluated by determining the equilibrium bubble size in the melt and calculating the pressure due to surface tension, assuming the latter to be 380 dyn/cm. The relative volatility from tektite melts of the oxides of Na, K, Fe, Al and Si has been determined as a function of temperature, total pressure arid roughly, of oxygen fugacity. The volatility of SiO2 is decreased and that of Na2O and K2O is increased in an oxygen-poor environment. Preliminary results indicate that volatilization at 2100??C under atmospheric pressure caused little or no change in the percentage Na2O and K2O. The ratio Fe3 Fe2 of the tektite is increased in ambient air at a pressure of 9 ?? 10-4 mm Hg (= 106.5 atm O2, partial pressure) at 2000??C. This suggests that tektites were formed either at lower oxygen pressures or that they are a product of incomplete oxidation of parent material with a still lower ferricferrous ratio. ?? 1964.

  3. 40 CFR 60.4112 - Changing Hg designated representative and alternate Hg designated representative; changes in...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Changing Hg designated representative and alternate Hg designated representative; changes in owners and operators. 60.4112 Section 60.4112... Generating Units Hg Designated Representative for Hg Budget Sources § 60.4112 Changing Hg designated...

  4. Pathways of CH3Hg and Hg ingestion in benthic organisms: an enriched isotope approach.

    Science.gov (United States)

    Taylor, Vivien F; Bugge, Deenie; Jackson, Brian P; Chen, Celia Y

    2014-05-06

    Mercury is a widespread contaminant in marine food webs, and identifying uptake pathways of mercury species, CH3Hg(+) and Hg(2+), into low trophic level organisms is important to understanding its entry into marine food webs. Enriched stable isotope tracers were used to study benthic vs. pelagic pathways of CH3Hg(+) and Hg(2+) uptake via food to the infaunal estuarine amphipod, Leptocheirus plumulosus. Algal cells differentially labeled with isotopically enriched CH3Hg(+) or Hg(2+) were added simultaneously to the sediment and water column of microcosms, and Hg species were monitored in amphipods and in sediment and water compartments. Methylation of Hg(2+) occurred during the course of the experiment, enhancing the uptake of Hg(2+) spikes. Trophic transfer of Hg from algae added to the water column was determined to be the major uptake route for amphipods, suggesting inputs of contaminated organic matter from the pelagic zone are important to mercury bioaccumulation even in organisms living in sediments.

  5. Elastic, dynamical, and electronic properties of LiHg and Li3Hg: First-principles study

    Science.gov (United States)

    Wang, Yan; Hao, Chun-Mei; Huang, Hong-Mei; Li, Yan-Ling

    2018-04-01

    The elastic, dynamical, and electronic properties of cubic LiHg and Li3Hg were investigated based on first-principles methods. The elastic constants and phonon spectral calculations confirmed the mechanical and dynamical stability of the materials at ambient conditions. The obtained elastic moduli of LiHg are slightly larger than those of Li3Hg. Both LiHg and Li3Hg are ductile materials with strong shear anisotropy as metals with mixed ionic, covalent, and metallic interactions. The calculated Debye temperatures are 223.5 K and 230.6 K for LiHg and Li3Hg, respectively. The calculated phonon frequency of the T2 g mode in Li3Hg is 326.8 cm-1. The p states from the Hg and Li atoms dominate the electronic structure near the Fermi level. These findings may inspire further experimental and theoretical study on the potential technical and engineering applications of similar alkali metal-based intermetallic compounds.

  6. Associations between bacterial infections and blood pressure in pregnancy.

    Science.gov (United States)

    Petry, Clive J; Ong, Ken K; Hughes, Ieuan A; Acerini, Carlo L; Dunger, David B

    2017-10-01

    To test the hypothesis that bacterial infections in pregnancy are related to maternal blood pressure. Bacterial infection was assessed using antibiotic usage as a surrogate and its association with blood pressure in pregnancy tested in the Cambridge Baby Growth Study. Antibiotic usage in pregnancy was self-reported in questionnaires. Blood pressure measurements at four time points in pregnancy were collected from the hospital notes of 622 women. Using all the available blood pressure readings (adjusted for weeks gestation) antibiotic usage was associated with a higher mean arterial blood pressure across pregnancy: antibiotics used 85(84, 87)mmHg vs. no antibiotics used 83 (83, 84) mmHg (β=2.3 (0.6, 4.0) mmHg, p=9.6×10 -3 , from 621 individuals). Further analysis revealed that antibiotic usage was associated with diastolic (β=2.3 (0.6, 4.0) mmHg; p=7.0×10 -3 ) more than systolic blood pressure (β=1.4(-0.9, 3.7)mmHg; p=0.2). The effect size associated with antibiotic usage appeared to rise slightly after the first trimester. Bacterial infection in pregnancy, as assessed by self-reported antibiotic usage, is associated with small rises in blood pressure. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  7. Food preferences and Hg distribution in Chelonia mydas assessed by stable isotopes

    International Nuclear Information System (INIS)

    Bezerra, M.F.; Lacerda, L.D.; Rezende, C.E.; Franco, M.A.L.; Almeida, M.G.; Macêdo, G.R.; Pires, T.T.; Rostán, G.; Lopez, G.G.

    2015-01-01

    Mercury (Hg) is a highly toxic pollutant that poses in risk several marine animals, including green turtles (Chelonia mydas). Green turtles are globally endangered sea turtle species that occurs in Brazilian coastal waters as a number of life stage classes (i.e., foraging juveniles and nesting adults). We assessed total Hg concentrations and isotopic signatures ("1"3C and "1"5N) in muscle, kidney, liver and scute of juvenile green turtles and their food items from two foraging grounds with different urban and industrial development. We found similar food preferences in specimens from both areas but variable Hg levels in tissues reflecting the influence of local Hg backgrounds in food items. Some juvenile green turtles from the highly industrialized foraging ground presented liver Hg levels among the highest ever reported for this species. Our results suggest that juvenile foraging green turtles are exposed to Hg burdens from locally anthropogenic activities in coastal areas. - Highlights: • We report major diet items for foraging green turtles from northeastern Brazil. • We compare Hg levels between industrialized and relatively pristine foraging grounds. • High local Hg background levels increase Hg exposure in foraging green turtles. • Even an herbivore diet could result in high tissue Hg concentrations. - Hg levels in scutes of foraging green turtles correlated with internal Hg burdens and were influenced by local sources of pollution in two tropical foraging grounds.

  8. Blood Pressure and Its Association with Gender, Body Mass Index, Smoking, and Family History among University Students

    Directory of Open Access Journals (Sweden)

    Hussein H. Alhawari

    2018-01-01

    Full Text Available Hypertension is one of the major risk factors associated with cardiovascular diseases. In this study, we will assess the frequency of hypertension among healthy university students and its association with gender, body mass index, smoking, and family history of both hypertension and cardiovascular diseases. We screened healthy university students ranging from 18 to 26 years of age. For each participant, we performed blood pressure measurements using a previously validated device and obtained demographic data, body mass index (BMI, smoking status, and family history of both hypertension and cardiovascular diseases. Out of the total number of 505 participants included in this study, 35.2% have blood pressure between 130/80 and 139/89, and 13.5% have blood pressure of more than 140/90. We found significant gender differences in both systolic pressure (p = 0.003 with mean difference = 18.08 mmHg (CI: 16.13 to 19.9 and diastolic pressure (p = 0.011 with mean difference = 3.6 mmHg (CI: 2.06 to 5.14, higher in males than in females. Upon comparing the mean difference in both systolic and diastolic blood pressure with BMI, we found significant differences in both systolic (p < 0.001 and diastolic (p = 0.002 blood pressure. We also found that smokers have significantly (p = 0.025 higher systolic blood pressure (mean difference = 4.2 mmHg, CI: 3.2 mmHg to 8.8 mmHg, but no significant difference for diastolic blood pressure (p = 0.386, compared to nonsmokers. First-degree family history of both hypertension and cardiovascular diseases affected systolic but not diastolic blood pressure. Taking into account the adverse short- and long-term effect of hypertension, we recommend adopting an awareness program highlighting the importance of screening blood pressure in young adolescent populations, keeping in mind that both high BMI and smoking are important modifiable factors.

  9. Alterations in biochemical markers due to mercury (Hg) exposure and its influence on infant's neurodevelopment.

    Science.gov (United States)

    Al-Saleh, Iman; Elkhatib, Rola; Al-Rouqi, Reem; Abduljabbar, Mai; Eltabache, Chafica; Al-Rajudi, Tahreer; Nester, Michael

    2016-11-01

    This study examined the role of oxidative stress due to mercury (Hg) exposure on infant's neurodevelopmental performance. A total of 944 healthy Saudi mothers and their respective infants (aged 3-12 months) were recruited from 57 Primary Health Care Centers in Riyadh City. Total mercury (Hg) was measured in mothers and infants urine and hair samples, as well as mother's blood and breast milk. Methylmercury (MeHg) was determined in the mothers and infants' hair and mother's blood. Urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG), malondialdehyde (MDA), and porphyrins were used to assess oxidative stress. The infant's neurodevelopment was evaluated using Denver Developmental Screening Test II (DDST-II) and Parents' Evaluation of Developmental Status. The median total Hg levels in mother's urine, infant's urine, mother's hair, infant's hair, and mother's blood and breast milk were 0.995μg/l, 0.716μg/l, 0.118μg/g dw, 0.101μg/g dw, 0.635μg/l, and 0.884μg/l respectively. The median MeHg levels in mother's hair, infant's hair, and mother's blood were 0.132μg/g dw, 0.091μg/g dw, and 2.341μg/l respectively. A significant interrelationship between mothers and infants Hg measures in various matrices was noted. This suggests that mother's exposure to different forms of Hg (total and/or MeHg) from various sources contributed significantly to the metal body burden of their respective infants. Even though Hg exposure was low, it induced high oxidative stress in mothers and infants. The influence of multiplicative interaction terms between Hg measures and oxidative stress biomarkers was tested using multiple regression analysis. Significant interactions between the urinary Hg levels in mothers and infants and oxidative stress biomarkers (8-OHdG and MDA) were noted. The MeHg levels in mother-infant hair revealed similar interaction patterns. The p-values for both were below 0.001. These observations suggest that the exposure of our infants to Hg via mothers either during

  10. Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer.

    Science.gov (United States)

    Cheng, Arthur C K; Leung, Dexter Y L; Cheung, Eva Y Y; Fan, Dorothy S P; Law, Ricky W K; Lam, Dennis S C

    2005-04-01

    To compare intraocular pressure (IOP) assessment in post-LASIK patients using non-contact tonometry, pressure phosphene tonometry and applanation tonometry. Sixty-two consecutive LASIK patients were analysed preoperatively and postoperatively with non-contact, pressure phosphene and applanation tonometry. Comparisons among these values were assessed with paired sample Student t-test, Pearson's correlation test and Bland-Altman plotting. There was no significant difference for preoperative IOP measurement between non-contact, pressure phosphene and applanation tonometry. The mean +/-SD difference between the preoperative non-contact tonometry and postoperative pressure phosphene tonometry IOP measurements was 0.80 +/- 2.77 mmHg (P contact tonometry significantly underestimated IOP measurement by 9.96 +/- 2.25 mmHg (P < 0.001). Pressure phosphene tonometry may provide an alternative method for the assessment of IOP in post-LASIK patients.

  11. Effect of Elodea nuttallii roots on bacterial communities and MMHg proportion in a Hg polluted sediment.

    Science.gov (United States)

    Regier, Nicole; Frey, Beat; Converse, Brandon; Roden, Eric; Grosse-Honebrink, Alexander; Bravo, Andrea Garcia; Cosio, Claudia

    2012-01-01

    The objective of this study was to assess the effect of a rooted macrophyte Elodea nuttallii on rhizosphere bacterial communities in Hg contaminated sediments. Specimens of E. nuttallii were exposed to sediments from the Hg contaminated Babeni reservoir (Olt River, Romania) in our microcosm. Plants were allowed to grow for two months until they occupied the entirety of the sediments. Total Hg and MMHg were analysed in sediments where an increased MMHg percentage of the total Hg in pore water of rhizosphere sediments was found. E. nuttallii roots also significantly changed the bacterial community structure in rhizosphere sediments compared to bulk sediments. Deltaproteobacteria dominated the rhizosphere bacterial community where members of Geobacteraceae within the Desulfuromonadales and Desulfobacteraceae were identified. Two bacterial operational taxonomic units (OTUs) which were phylogenetically related to sulfate-reducing bacteria (SRB) became abundant in the rhizosphere. We suggest that these phylotypes could be potentially methylating bacteria and might be responsible for the higher MMHg percentage of the total Hg in rhizosphere sediments. However, SRB were not significantly favoured in rhizosphere sediments as shown by qPCR. Our findings support the hypothesis that rooted macrophytes created a microenvironment favorable for Hg methylation. The presence of E. nuttallii in Hg contaminated sediments should therefore not be overlooked.

  12. Effect of Elodea nuttallii roots on bacterial communities and MMHg proportion in a Hg polluted sediment.

    Directory of Open Access Journals (Sweden)

    Nicole Regier

    Full Text Available The objective of this study was to assess the effect of a rooted macrophyte Elodea nuttallii on rhizosphere bacterial communities in Hg contaminated sediments. Specimens of E. nuttallii were exposed to sediments from the Hg contaminated Babeni reservoir (Olt River, Romania in our microcosm. Plants were allowed to grow for two months until they occupied the entirety of the sediments. Total Hg and MMHg were analysed in sediments where an increased MMHg percentage of the total Hg in pore water of rhizosphere sediments was found. E. nuttallii roots also significantly changed the bacterial community structure in rhizosphere sediments compared to bulk sediments. Deltaproteobacteria dominated the rhizosphere bacterial community where members of Geobacteraceae within the Desulfuromonadales and Desulfobacteraceae were identified. Two bacterial operational taxonomic units (OTUs which were phylogenetically related to sulfate-reducing bacteria (SRB became abundant in the rhizosphere. We suggest that these phylotypes could be potentially methylating bacteria and might be responsible for the higher MMHg percentage of the total Hg in rhizosphere sediments. However, SRB were not significantly favoured in rhizosphere sediments as shown by qPCR. Our findings support the hypothesis that rooted macrophytes created a microenvironment favorable for Hg methylation. The presence of E. nuttallii in Hg contaminated sediments should therefore not be overlooked.

  13. ORANGE JUICE AND BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    M. F. VALIM

    2009-01-01

    Full Text Available

    Blood pressure is the force of blood against artery walls. It is measured in millimeters of mercury (mm Hg and recorded as two numbers: systolic pressure (as the heart contracts over diastolic pressure (as the heart relaxes between beats. High blood pressure (hypertension is defined as chronically elevated high blood pressure, with systolic blood pressure (SBP of 140 mm Hg or greater, and diastolic blood pressure (DBP of 90 mm Hg or greater. High blood pressure (HBP, smoking, abnormal blood lipid levels, obesity and diabetes are risk factors for coronary heart disease, the leading cause of death in the US. Lifestyle modifications such as engaging in regular physical activity, quitting smoking and eating a healthy diet (limiting intake of saturated fat and sodium and increasing consumption of fiber, fruits and vegetables are advocated for the prevention, treatment, and control of HBP. As multiple factors influence blood pressure, the effects of each factor are typically modest, particularly in normotensive subjects, yet the combined effects can be substantial. Nutrition plays an important role in influencing blood pressure. Orange juice should be included as part of any low sodium diet and/or any blood pressure reducing eating plan, as it is sodium free, fat-free and can help meet recommended levels of potassium intake that may contribute to lower BP.

  14. The calorically restricted low-fat nutrient-dense diet in Biosphere 2 significantly lowers blood glucose, total leukocyte count, cholesterol, and blood pressure in humans.

    Science.gov (United States)

    Walford, R L; Harris, S B; Gunion, M W

    1992-12-01

    Biosphere 2 is a 3.15-acre space containing an ecosystem that is energetically open (sunlight, electric power, and heat) but materially closed, with air, water, and organic material being recycled. Since September 1991, eight subjects (four women and four men) have been sealed inside, living on food crops grown within. Their diet, low in calories (average, 1780 kcal/day; 1 kcal = 4.184 kJ), low in fat (10% of calories), and nutrient-dense, conforms to that which in numerous animal experiments has promoted health, retarded aging, and extended maximum life span. We report here medical data on the eight subjects, comparing preclosure data with data through 6 months of closure. Significant changes included: (i) weight, 74 to 62 kg (men) and 61 to 54 kg (women); (ii) mean systolic/diastolic blood pressure (eight subjects), 109/74 to 89/58 mmHg (1 mmHg = 133 Pa); (iii) total serum cholesterol, from 191 +/- 11 to 123 +/- 9 mg/dl (mean +/- SD; 36% mean reduction), and high density lipoprotein, from 62 +/- 8 to 38 +/- 5 (risk ratio unchanged); (iv) triglyceride, 139 to 96 mg/dl (men) and 78 to 114 mg/dl (women); (v) fasting glucose, 92 to 74 mg/dl; (vi) leukocyte count, 6.7 to 4.7 x 10(9) cells per liter. We conclude that drastic reductions in cholesterol and blood pressure may be instituted in normal individuals in Western countries by application of a carefully chosen diet and that a low-calorie nutrient-dense regime shows physiologic features in humans similar to those in other animal species.

  15. Triaxiality in the even-mass Hg isotopes: A discontinuity at 200Hg

    International Nuclear Information System (INIS)

    Morrison, I.; Spear, R.H.

    1981-01-01

    The mass dependence of excitation energies of the 2 + 1 , 2 + 2 , and 4 + 1 states of the even-mass Hg isotopes, and of some related B(E2) values, shows a marked discontinuity at 200 Hg. Analysis of B(E2;0 + 1 →2 + 1 ) values in terms of an extended interacting boson approximation model suggests that this discontinuity is due to a change in the proton and neutron distributions at 200 Hg. Apart from 200 Hg, the data favor γ-soft models rather than the rigid triaxial-rotor model

  16. Intraocular Pressure Increases After Intraarticular Knee Injection With Triamcinolone but Not Hyaluronic Acid.

    Science.gov (United States)

    Taliaferro, Kevin; Crawford, Alexander; Jabara, Justin; Lynch, Jonathan; Jung, Edward; Zvirbulis, Raimonds; Banka, Trevor

    2018-03-09

    Intraarticular steroid injections are a common first-line therapy for severe osteoarthritis, which affects an estimated 27 million people in the United States. Although topical, oral, intranasal, and inhalational steroids are known to increase intraocular pressure in some patients, the effect of intraarticular steroid injections on intraocular pressure has not been investigated, to the best of our knowledge. If elevated intraocular pressure is sustained for long periods of time or is of sufficient magnitude acutely, permanent loss of the visual field can occur. How does intraocular pressure change 1 week after an intraarticular knee injection either with triamcinolone acetonide or hyaluronic acid? A nonrandomized, nonblinded prospective cohort study was conducted at an outpatient, ambulatory orthopaedic clinic. This study compared intraocular pressure elevation before and 1 week after intraarticular knee injection of triamcinolone acetonide versus hyaluronic acid for management of primary osteoarthritis of the knee. Patients self-selected to be injected in their knee with either triamcinolone acetonide or hyaluronic acid before being informed of the study. The primary endpoint was intraocular pressure elevation of ≥ 7 mm Hg 1 week after injection. This cutoff is determined as the minimum significant pressure change in the ophthalmology literature recognized as an intermediate responder to steroids. Intraocular pressure was measured using a handheld Tono-Pen® applanation device. This device is frequently used in intraocular pressure measurement in clinical and research settings; 10 sequential measurements are obtained and averaged with a confidence interval. Only measurements with a 95% confidence interval were used. Over a 6-month period, a total of 96 patients were approached to enroll in the study. Sixty-two patients out of 96 approached (65%) agreed. Thirty-one (50%) were injected with triamcinolone and 31 (50%) were injected with hyaluronic acid. Patients

  17. On the mean square displacements (MSD) of Hg and Te in HgTe

    International Nuclear Information System (INIS)

    Madhavan, Y.; Ramachandran, K.

    1989-01-01

    The mean square displacements (MSD) of Hg and Te in the perfect system of HgTe are worked out in the modified rigid ion model of Plumelle and Vandevyver. Also the MSD of Hg and Te neighbours around anion and cation vacancies in HgTe are worked out giving an active role for the vacancy following the theory of Maradudin et al. The results are compared with experimental values. (author)

  18. Lattice defects in semiconducting Hg/1-x/Cd/x/Te alloys. I - Defect structure of undoped and copper doped Hg/0.8/Cd/0.2/Te. II - Defect structure of indium-doped Hg/0.8/Cd/0.2/Te

    Science.gov (United States)

    Vydyanath, H. R.

    1981-01-01

    Hall effect and mobility measurements were conducted on undoped Hg(0.8)Cd(0.2)Te crystals which were quenched to room temperature after being subjected to equilibration at temperatures ranging from 400 to 655 C in various Hg atmospheres. The variation of the hole concentration in the cooled crystals at 77 K as a function of Hg's partial pressure at the equilibration temperature, together with a comparison of the hole mobility in the undoped samples with that in copper-doped ones, yields a defect model for the undoped crystals according to which they are intrinsic at the equilibration temperatures and the native acceptor defects are doubly ionized. In the second part of this paper, the effects of indium doping are considered. The concentration of electrons obtained in the cooled crystals was found to be lower than the intrinsic carrier concentration at the equilibration temperatures. A defect model is proposed according to which most of the indium is incorporated as In2Te3(s) dissolved in the crystal, with only a small fraction of indium acting as single donors occupying Hg lattice sites.

  19. Maternal-fetal distribution of mercury (203Hg) released from dental amalgam fillings

    International Nuclear Information System (INIS)

    Vimy, M.J.; Takahashi, Y.; Lorscheider, F.L.

    1990-01-01

    In humans, the continuous release of Hg vapor from dental amalgam tooth restorations is markedly increased for prolonged periods after chewing. The present study establishes a time-course distribution for amalgam Hg in body tissues of adult and fetal sheep. Under general anesthesia, five pregnant ewes had twelve occlusal amalgam fillings containing radioactive 203Hg placed in teeth at 112 days gestation. Blood, amniotic fluid, feces, and urine specimens were collected at 1- to 3-day intervals for 16 days. From days 16-140 after amalgam placement (16-41 days for fetal lambs), tissue specimens were analyzed for radioactivity, and total Hg concentrations were calculated. Results demonstrate that Hg from dental amalgam will appear in maternal and fetal blood and amniotic fluid within 2 days after placement of amalgam tooth restorations. Excretion of some of this Hg will also commence within 2 days. All tissues examined displayed Hg accumulation. Highest concentrations of Hg from amalgam in the adult occurred in kidney and liver, whereas in the fetus the highest amalgam Hg concentrations appeared in liver and pituitary gland. The placenta progressively concentrated Hg as gestation advanced to term, and milk concentration of amalgam Hg postpartum provides a potential source of Hg exposure to the newborn. It is concluded that accumulation of amalgam Hg progresses in maternal and fetal tissues to a steady state with advancing gestation and is maintained. Dental amalgam usage as a tooth restorative material in pregnant women and children should be reconsidered

  20. Does chocolate reduce blood pressure? A meta-analysis.

    Science.gov (United States)

    Ried, Karin; Sullivan, Thomas; Fakler, Peter; Frank, Oliver R; Stocks, Nigel P

    2010-06-28

    Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP) for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive). Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P chocolate compared with control (mean BP change +/- SE: SBP: -3.2 +/- 1.9 mmHg, P = 0.001; DBP: -2.0 +/- 1.3 mmHg, P = 0.003). However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 +/- 3.0 mmHg; P = 0.0009; DBP: -2.7 +/- 2.2 mm Hg, P = 0.01), while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 +/- 2.3 mmHg, P = 0.17; DBP: -1.3 +/- 1.6 mmHg, P = 0.12). Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30 mg to 1000 mg in the active treatment groups, and interventions ran for 2 to 18 weeks. Meta-regression analysis found study design and type of control to be borderline significant but possibly indirect predictors

  1. Effects of mercury on the arterial blood pressure of anesthetized rats

    Directory of Open Access Journals (Sweden)

    Rossoni L.V.

    1999-01-01

    Full Text Available The available data suggests that hypotension caused by Hg2+ administration may be produced by a reduction of cardiac contractility or by cholinergic mechanisms. The hemodynamic effects of an intravenous injection of HgCl2 (5 mg/kg were studied in anesthetized rats (N = 12 by monitoring left and right ventricular (LV and RV systolic and diastolic pressures for 120 min. After HgCl2 administration the LV systolic pressure decreased only after 40 min (99 ± 3.3 to 85 ± 8.8 mmHg at 80 min. However, RV systolic pressure increased, initially slowly but faster after 30 min (25 ± 1.8 to 42 ± 1.6 mmHg at 80 min. Both right and left diastolic pressures increased after HgCl2 treatment, suggesting the development of diastolic ventricular dysfunction. Since HgCl2 could be increasing pulmonary vascular resistance, isolated lungs (N = 10 were perfused for 80 min with Krebs solution (continuous flow of 10 ml/min containing or not 5 µM HgCl2. A continuous increase in pulmonary vascular resistance was observed, suggesting the direct effect of Hg2+ on the pulmonary vessels (12 ± 0.4 to 29 ± 3.2 mmHg at 30 min. To examine the interactions of Hg2+ and changes in cholinergic activity we analyzed the effects of acetylcholine (Ach on mean arterial blood pressure (ABP in anesthetized rats (N = 9 before and after Hg2+ treatment (5 mg/kg. Using the same amount and route used to study the hemodynamic effects we also examined the effects of Hg2+ administration on heart and plasma cholinesterase activity (N = 10. The in vivo hypotensive response to Ach (0.035 to 10.5 µg was reduced after Hg2+ treatment. Cholinesterase activity (µM h-1 mg protein-1 increased in heart and plasma (32 and 65%, respectively after Hg2+ treatment. In conclusion, the reduction in ABP produced by Hg2+ is not dependent on a putative increase in cholinergic activity. HgCl2 mainly affects cardiac function. The increased pulmonary vascular resistance and cardiac failure due to diastolic

  2. Absence of Hg transpiration by shoot after Hg uptake by roots of six terrestrial plant species

    International Nuclear Information System (INIS)

    Greger, Maria; Wang Yaodong; Neuschuetz, Clara

    2005-01-01

    In this paper we investigated if, and to what extent, six different plant species accumulate, translocate and emit mercury (Hg) into the air. The Hg uptake by roots, distribution of Hg to the shoot and release of Hg via shoots of garden pea, spring wheat, sugar beet, oil-seed rape, white clover and willow were investigated in a transpiration chamber. The airborne Hg was trapped in a Hopcalite trap or a gold trap. Traps and plant materials were analysed for content of Hg by CVAAS. The results show that all plant species were able to take up Hg to a large extent from a nutrient solution containing 200 μg L -1 Hg. However, the Hg translocation to the shoot was low (0.17-2.5%) and the Hg that reached the leaves was trapped and no release of the absorbed Hg to the air was detected. - Mercury translocation to shoots was low

  3. Tourniquet pressures: strap width and tensioning system widths.

    Science.gov (United States)

    Wall, Piper L; Coughlin, Ohmar; Rometti, Mary; Birkholz, Sarah; Gildemaster, Yvonne; Grulke, Lisa; Sahr, Sheryl; Buising, Charisse M

    2014-01-01

    Pressure distribution over tourniquet width is a determinant of pressure needed for arterial occlusion. Different width tensioning systems could result in arterial occlusion pressure differences among nonelastic strap designs of equal width. Ratcheting Medical Tourniquets (RMTs; m2 inc., http://www.ratcheting buckles.com) with a 1.9 cm-wide (Tactical RMT) or 2.3 cm-wide (Mass Casualty RMT) ladder were directly compared (16 recipients, 16 thighs and 16 upper arms for each tourniquetx2). Then, RMTs were retrospectively compared with the windlass Combat Application Tourniquet (C-A-T ["CAT"], http://combattourniquet.com) with a 2.5 cm-wide internal tensioning strap. Pressure was measured with an air-filled No. 1 neonatal blood pressure cuff under each 3.8 cm-wide tourniquet. RMT circumferential pressure distribution was not uniform. Tactical RMT pressures were not higher, and there were no differences between the RMTs in the effectiveness, ease of use ("97% easy"), or discomfort. However, a difference did occur regarding tooth skipping of the pawl during ratchet advancement: it occurred in 1 of 64 Tactical RMT applications versus 27 of 64 Mass Casualty RMT applications. CAT and RMT occlusion pressures were frequently over 300 mmHg. RMT arm occlusion pressures (175-397 mmHg), however, were lower than RMT thigh occlusion pressures (197-562 mmHg). RMT effectiveness was better with 99% reached occlusion and 1% lost occlusion over 1 minute versus the CAT with 95% reached occlusion and 28% lost occlusion over 1 minute. RMT muscle tension changes (up to 232 mmHg) and pressure losses over 1 minute (24±11 mmHg arm under strap to 40±12 mmHg thigh under ladder) suggest more occlusion losses may have occurred if tourniquet duration was extended. The narrower tensioning system Tactical RMT has better performance characteristics than the Mass Casualty RMT. The 3.8 cm-wide RMTs have some pressure and effectiveness similarities and differences compared with the CAT. Clinically

  4. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  5. Influence of short-term blood pressure variability on blood pressure determinations

    NARCIS (Netherlands)

    Bos, W. J.; van Goudoever, J.; van Montfrans, G. A.; Wesseling, K. H.

    1992-01-01

    To evaluate the effect of blood pressure variability on Riva Rocci Korotkoff blood pressure determinations, we studied the intra-arterial pressure during Riva Rocci Korotkoff determinations in 25 patients. In 50 measurements with a cuff deflation rate of 2.5 mm Hg/sec, the systolic intra-arterial

  6. Improvement of Diurnal Blood Pressure Variation by Azilsartan.

    Science.gov (United States)

    Okamura, Keisuke; Shirai, Kazuyuki; Okuda, Tetsu; Urata, Hidenori

    2018-01-01

    Azilsartan is an angiotensin II receptor blocker with a potent antihypertensive effect. In a multicenter, prospective, open-label study, 265 patients with poor blood pressure control despite treatment with other angiotensin II receptor blockers were switched to 20 mg/day of azilsartan (patients on standard dosages) or 40 mg/day of azilsartan (patients on high dosages). Blood pressure was 149/83 mm Hg before switching and was significantly reduced from 1 month after switching until final assessment (132/76 mm Hg, P < 0.001). The pulse rate was 72/min before switching and increased significantly from 3 months after switching until final assessment (74/min, P < 0.005). A significant decrease of home morning systolic and diastolic pressure was observed from 1 and 3 months, respectively. Home morning blood pressure was 143/82 mm Hg before switching and 130/76 mm Hg at final assessment (P < 0.01). The morning-evening difference of systolic blood pressure decreased from 14.6 to 6.6 mm Hg after switching (P = 0.09). The estimated glomerular filtration rate was significantly decreased at 3, 6, and 12 months after switching, and serum uric acid was significantly increased at 12 months. No serious adverse events occurred. Azilsartan significantly reduced the blood pressure and decreased diurnal variation in patients responding poorly to other angiotensin II receptor blockers.

  7. Hyperemesis Gravidarum (HG)

    Science.gov (United States)

    ... Treatments Risks Complications Impact Take a Poll If HG continued past mid-pregnancy , did you experience complications ... Understanding Hyperemesis | Overview About Hyperemesis Gravidarum Hyperemesis gravidarum (HG) is a severe form of nausea and vomiting ...

  8. Admission Systolic Blood Pressure Predicts the Number of Blood Pressure Medications at Discharge in Patients With Primary Intracerebral Hemorrhage.

    Science.gov (United States)

    Khawaja, Ayaz M; Shiue, Harn; Boehme, Amelia K; Albright, Karen C; Venkatraman, Anand; Kumar, Gyanendra; Lyerly, Michael J; Hays-Shapshak, Angela; Mirza, Maira; Gropen, Toby I; Harrigan, Mark R

    2018-03-01

    Control of systolic blood pressure (SBP) after primary intracerebral hemorrhage improves outcomes. Factors determining the number of blood pressure medications (BPM) required for goal SBP<160 mm Hg at discharge are unknown. We hypothesized that higher admission-SBPs require a greater number of BPM for goal discharge-SBP<160 mm Hg, and investigated factors influencing this goal. We conducted a retrospective review of 288 patients who presented with primary intracerebral hemorrhage. Admission-SBP was obtained. Primary outcome was the number of BPM at discharge. Comparison was made between patients presenting with and without a history of hypertension, and patients discharged on <3 and ≥3 BPM. Patients with hypertension history had a higher median admission-SBP compared with those without (180 vs. 157 mm Hg, P=0.0001). In total, 133 of 288 (46.2%) patients were discharged on <3 BPM; 155/288 (53.8%) were discharged on ≥3 BPM. Hypertension history (P<0.0001) and admission-SBP (P<0.0001) predicted the number of BPM at discharge. In patients without hypertension history, every 10 mm Hg increase in SBP resulted in an absolute increase of 0.5 BPM at discharge (P=0.0011), whereas in those with hypertension, the absolute increase was 1.3 BPM (P=0.0012). In comparison with patients discharged on <3 BPM, patients discharged on ≥3 BPM were more likely to have a higher median admission-SBP, be younger in age, belong to the African-American race, have a history of diabetes, have higher median admission-National Institutes of Health Stroke Scale and modified Rankin Scale of 4 to 5 at discharge. An understanding of the factors influencing BPM at discharge may help clinicians better optimize blood pressure control both before and after discharge.

  9. The impact of altering filling pressures in diagnostic outpatient hysteroscopy on the procedure completion rates and associated pain: a randomised double-blind controlled trial.

    Science.gov (United States)

    Haggag, Hisham M; Hassan, AbdelGany M A

    2016-02-01

    Several studies have compared different distension media and analgesics to optimise the efficiency of outpatient hysteroscopy. However, studies comparing different uterine filling pressures are scarce. The objective of this study was to evaluate and compare different uterine filling pressures during diagnostic outpatient hysteroscopy in an attempt to find the optimal pressure allowing adequate visualisation while minimising pain and increasing patient satisfaction. This was a double-blind randomised controlled trial. A total of 240 women who had diagnostic outpatient hysteroscopy were randomly divided into three equal groups: the uterine filling pressure was 30 mm Hg in group 1, 50 mm Hg in group 2 and 80 mm Hg in group 3. The primary outcome was adequate visualisation, and secondary outcomes were the proportion of completed procedures, pain perceived during the procedure, immediately after the procedure and 30 min later. Adequate visualisation was lower in group 1 (88.7% vs 97.5% and 98.7%; P = 0.009), but was not different between groups 2 and 3 (P > 0.999). The proportion of completed procedures was not different among the groups. There was a progressive increase in pain scores from the lower to the higher pressure groups during the procedure, immediately after the procedure and 30 min after completing the procedure. Uterine filling pressure of 50 mm Hg was associated with better visualisation than 30 mm Hg and lower pain scores than that of 80 mmHg with no difference in the proportion of completed procedures. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  10. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    Science.gov (United States)

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  11. Photoionization study of HgAr

    International Nuclear Information System (INIS)

    Linn, S.H.; Brom, J.M. Jr.; Tzeng, W.; Ng, C.Y.

    1985-01-01

    Photoionization efficiency data for HgAr + have been obtained in the region of 680--1240 A. The ionization energy of HgAr was determined to be 10.217 +- 0.012 eV. This value allows the calculation of the dissociation energy of HgAr + to be 0.228 +- 0.017 eV. The relative probabilities for the formation of HgAr + via the reactions Ar* x Hg or Hg* x Ar→ HgAr + +e - with Ar* and Hg* prepared in high Rydberg states in the energy range of 10.22--15.79 eV were estimated. Although the radii for the 3d and 5s Rydberg ortitals of Ar have similar values, the probabilities for the formation of HgAr + from Hg x Ar* with Ar* in the 5s[3/2] 0 1 and 5s'[1/2] 0 1 Rydberg states are substantially greater than those when the Ar* excited atoms are in the 3d[1/2] 0 1 , 3s[3/2] 0 1 , and 3d'[3/2] 0 1 Rydberg levels. The ratio for the cross sections for the formation of HgAr + from Hg x Ar* with Ar* formed in the 3d[1/2] 0 1 and 4d[1/2] 0 1 states, as well as that with Ar* prepared in the 5d[1/2] 0 1 and 6d[1/2] 0 1 states, were found to be consistent with the predictions of the previous impact parameter calculations

  12. Blood pressure control to prevent decline in cognition after stroke

    Directory of Open Access Journals (Sweden)

    Ihle-Hansen H

    2015-06-01

    Full Text Available Hege Ihle-Hansen,1 Bente Thommessen,2 Morten W Fagerland,3 Anne R Øksengård,4 Torgeir B Wyller,5 Knut Engedal,6 Brynjar Fure7 1Department of Internal Medicine, Vestre Viken Hospital Trust, Bærum Hospital, Bærum, Norway; 2Department of Neurology, Akershus University Hospital, Lørenskog, Norway; 3Oslo Centre for Biostatistics and Epidemiology, Research Support Services, Oslo University Hospital, Norway; 4Department of Internal medicine, Vestre Viken Hospital Trust, Bærum Hospital, Bærum, Norway; 5Department of Geriatric Medicine, Oslo University Hospital, Oslo, Norway; 6Norwegian Centre for Dementia Research, Oslo University Hospital, Oslo, Norway; 7Norwegian Knowledge Centre for the Health Services, Oslo, Norway Background: Treatment of hypertension post-stroke preserves cognition through prevention of recurrent stroke, but it is not clear whether it prevents cognitive decline through other mechanisms. We aimed to describe changes in blood pressure from baseline to 1 year post-stroke and to evaluate the association between achieved blood pressure targets and cognitive function, mild cognitive impairment (MCI, and dementia.Methods: We included patients with first-ever stroke, and defined achieved blood pressure goals as systolic blood pressure (SBP in the categories ≤125 mmHg, ≤140 mmHg, and ≤160 mmHg, SBP reduction of ≥10 mmHg, and diastolic blood pressure (DBP reduction of ≥5 mmHg. The main outcome variables were cognitive assessments 1 year post stroke. Secondary outcomes were diagnoses of MCI or dementia.Results: Forty-one of 166 patients (25% reached SBP ≤125 mmHg after 1 year, 92/166 (55% reached SBP ≤140 mmHg, and 150/166 (90% reached SBP ≤160 mmHg. SBP was reduced by ≥10 mmHg in 44/150 (29% and DBP by ≥5 mmHg in 57/150 (38%. We did not find any statistically significant associations between cognitive test performances and different blood pressure goals (P=0.070–1.0. Nor was there any significant association

  13. Multicomponent exercise decreases blood pressure, heart rate and double product in normotensive and hypertensive older patients with high blood pressure.

    Science.gov (United States)

    Coelho-Júnior, Hélio José; Asano, Ricardo Yukio; Gonçalvez, Ivan de Oliveira; Brietzke, Cayque; Pires, Flávio Oliveira; Aguiar, Samuel da Silva; Feriani, Daniele Jardim; Caperuto, Erico Chagas; Uchida, Marco Carlos; Rodrigues, Bruno

    2018-02-26

    The present study aimed to investigate the effects of a 6-month multicomponent exercise program on blood pressure, heart rate, and double product of uncontrolled and controlled normotensive and hypertensive older patients. The study included 183 subjects, 97 normotensives, of which 53 were controlled normotensives (CNS), and 44 uncontrolled normotensives (UNS), as well as 86 hypertensives, of which 43 were controlled hypertensives (CHS), and 43 uncontrolled hypertensives (UHS). Volunteers were recruited and blood pressure and heart rate measurements were made before and after a 6-month multicomponent exercise program. The program of physical exercise was performed twice a week for 26 weeks. The physical exercises program was based on functional and walking exercises. Exercise sessions were performed at moderate intensity. The results indicated that UHS showed a marked decrease in systolic (-8.0mmHg), diastolic (-11.1mmHg), mean (-10.1mmHg), and pulse pressures, heart rate (-6.8bpm), and double product (-1640bpmmmHg), when compared to baseline. Similarly, diastolic (-5.5mmHg) and mean arterial (-4.8mmHg) pressures were significantly decreased in UNS. Concomitantly, significant changes could be observed in the body mass index (-0.9kg/m 2 ; -1.5kg/m 2 ) and waist circumference (-3.3cm; only UHS) of UNS and UHS, which may be associated with the changes observed in blood pressure. In conclusion, the data of the present study indicate that a 6-month multicomponent exercise program may lead to significant reductions in blood pressure, heart rate, and double product of normotensive and hypertensive patients with high blood pressure values. Copyright © 2018 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  14. Does chocolate reduce blood pressure? A meta-analysis

    Directory of Open Access Journals (Sweden)

    Ried Karin

    2010-06-01

    Full Text Available Abstract Background Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. Methods We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive. Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P Results Fifteen trial arms of 13 assessed studies met the inclusion criteria. Pooled meta-analysis of all trials revealed a significant blood pressure-reducing effect of cocoa-chocolate compared with control (mean BP change ± SE: SBP: -3.2 ± 1.9 mmHg, P = 0.001; DBP: -2.0 ± 1.3 mmHg, P = 0.003. However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 ± 3.0 mmHg; P = 0.0009; DBP: -2.7 ± 2.2 mm Hg, P = 0.01, while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 ± 2.3 mmHg, P = 0.17; DBP: -1.3 ± 1.6 mmHg, P = 0.12. Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30

  15. Relationship Between Urinary Nitrate Excretion and Blood Pressure in the InChianti Cohort.

    Science.gov (United States)

    Smallwood, Miranda J; Ble, Alessandro; Melzer, David; Winyard, Paul G; Benjamin, Nigel; Shore, Angela C; Gilchrist, Mark

    2017-07-01

    Inorganic nitrate from the oxidation of endogenously synthesized nitric oxide (NO) or consumed in the diet can be reduced to NO via a complex enterosalivary circulation pathway. The relationship between total nitrate exposure by measured urinary nitrate excretion and blood pressure in a large population sample has not been assessed previously. For this cross-sectional study, 24-hour urinary nitrate excretion was measured by spectrophotometry in the 919 participants from the InChianti cohort at baseline and blood pressure measured with a mercury sphygmomanometer. After adjusting for age and sex only, diastolic blood pressure was 1.9 mm Hg lower in subjects with ≥2 mmol urinary nitrate excretion compared with those excreting nitrate in 24 hours: systolic blood pressure was 3.4 mm Hg (95% confidence interval (CI): -3.5 to -0.4) lower in subjects for the same comparison. Effect sizes in fully adjusted models (for age, sex, potassium intake, use of antihypertensive medications, diabetes, HS-CRP, or current smoking status) were marginally larger: systolic blood pressure in the ≥2 mmol urinary nitrate excretion group was 3.9 (CI: -7.1 to -0.7) mm Hg lower than in the comparison nitrate exposure are associated with lower blood pressure. These differences are at least equivalent to those seen from substantial (100 mmol) reductions in sodium intake. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  16. The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic discharges.

    Science.gov (United States)

    Eide, Per K; Bakken, André

    2011-08-22

    The monitoring of intracranial pressure (ICP) has a crucial role in the surveillance of patients with brain injury. During long-term monitoring of ICP, we have seen spontaneous shifts in baseline pressure (ICP sensor zero point), which are of technical and not physiological origin. The aim of the present study was to explore whether or not baseline pressures of ICP sensors can be affected by electrostatics discharges (ESD's), when ESD's are delivered at clinically relevant magnitudes. We performed bench-testing of a set of commercial ICP sensors. In our experimental setup, the ICP sensor was placed in a container with 0.9% NaCl solution. A test person was charged 0.5-10 kV, and then delivered ESD's to the sensor by touching a metal rod that was located in the container. The continuous pressure signals were recorded continuously before/after the ESD's, and the pressure readings were stored digitally using a computerized system A total of 57 sensors were tested, including 25 Codman ICP sensors and 32 Raumedic sensors. When charging the test person in the range 0.5-10 kV, typically ESD's in the range 0.5-5 kV peak pulse were delivered to the ICP sensor. Alterations in baseline pressure ≥ 2 mmHg was seen in 24 of 25 (96%) Codman sensors and in 17 of 32 (53%) Raumedic sensors. Lasting changes in baseline pressure > 10 mmHg that in the clinical setting would affect patient management, were seen frequently for both sensor types. The changes in baseline pressure were either characterized by sudden shifts or gradual drifts in baseline pressure. The baseline pressures of commercial solid ICP sensors can be altered by ESD's at discharge magnitudes that are clinically relevant. Shifts in baseline pressure change the ICP levels visualised to the physician on the monitor screen, and thereby reveal wrong ICP values, which likely represent a severe risk to the patient.

  17. The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure

    Directory of Open Access Journals (Sweden)

    Ilhan Ece

    2015-01-01

    Full Text Available Objective. This study aims to explore the usage of intraocular pressure measurements as the early indicator of the increase in intra-abdominal pressure. Methods. In this prospective study, 40 patients undergoing elective surgery were included. Patients were divided into four groups of 10 patients. The control group (Group C was not subjected to laparoscopic intervention. Laparoscopic surgery was, respectively, performed with an intra-abdominal pressure of 9, 12, and 15 mmHg in Groups L (low, M (medium, and H (high pressure. Intraocular pressure was measured binocularly in each patient at three different times (before, during, and end of surgery using a contact tonometer. Results. Patients’ gender, age, body mass index (BMI, American Society of Anesthesiology (ASA class, and operative times were not different among the groups. No complications occurred with either the surgery or measurement of intraocular pressure. Intubation was associated with a severe rise in IOP (P<0.05. An increase in intraocular pressure was seen in groups M and H (P<0.05. Conclusion. Intraocular pressure was increased in the groups with an intra-abdominal pressure of 12 mmHg or more. Measuring the intraocular pressure might be a useful method to estimate the intra-abdominal pressure. This trial is registered with NCT02319213.

  18. Genetic variants in novel pathways influence blood pressure and cardiovascular disease risk

    NARCIS (Netherlands)

    G.B. Ehret (Georg); P. Munroe (Patricia); K.M. Rice (Kenneth); M. Bochud (Murielle); A.D. Johnson (Andrew); D.I. Chasman (Daniel); A.V. Smith (Albert Vernon); M.D. Tobin (Martin); G.C. Verwoert (Germaine); S.J. Hwang; V. Pihur (Vasyl); P. Vollenweider (Peter); P.F. O'Reilly (Paul); N. Amin (Najaf); J.L. Bragg-Gresham (Jennifer L.); A. Teumer (Alexander); N.L. Glazer (Nicole); L.J. Launer (Lenore); J.H. Zhao (Jing Hua); Y.S. Aulchenko (Yurii); S.C. Heath (Simon); S. Sõber (Siim); A. Parsa (Afshin); J. Luan; P. Arora (Pankaj); A. Dehghan (Abbas); F. Zhang (Feng); G. Lucas (Gavin); A.A. Hicks (Andrew); A.U. Jackson (Anne); J. Peden (John); T. Tanaka (Toshiko); S.H. Wild (Sarah); I. Rudan (Igor); W. Igl (Wilmar); Y. Milaneschi (Yuri); A.N. Parker (Alex); C. Fava (Cristiano); J.C. Chambers (John); E.R. Fox (Ervin); M. Kumari (Meena); M. Jin Go (Min); P. van der Harst (Pim); W. Hong Linda Kao (Wen); M. Sjögren (Marketa); D.G. Vinay; M. Alexander (Myriam); Y. Tabara (Yasuharu); S. Shaw-Hawkins (Sue); P.H. Whincup (Peter); Y. Liu (YongMei); G. Shi (Gang); J. Kuusisto (Johanna); B. Tayo (Bamidele); M. Seielstad (Mark); X. Sim (Xueling); K.-D. Hoang Nguyen; T. Lehtimäki (Terho); G. Matullo (Giuseppe); Y. Wu (Ying); T.R. Gaunt (Tom); N. Charlotte Onland-Moret; M.N. Cooper (Matthew); C. Platou (Carl); E. Org (Elin); R. Hardy (Rebecca); S. Dahgam (Santosh); J. Palmen (Jutta); V. Vitart (Veronique); P.S. Braund (Peter); T. Kuznetsova (Tatiana); C.S.P.M. Uiterwaal (Cuno); A. Adeyemo (Adebowale); W. Palmas (Walter); H. Campbell (Harry); B. Ludwig (Barbara); M. Tomaszewski; I. Tzoulaki; N.D. Palmer (Nicholette); T. Aspelund (Thor); M. Garcia (Melissa); Y.-P.C. Chang (Yen-Pei); J.R. O´Connell; N.I. Steinle (Nanette); D.E. Grobbee (Diederick); D.E. Arking (Dan); S.L. Kardia (Sharon); A.C. Morrison (Alanna); D.G. Hernandez (Dena); S.S. Najjar (Samer); W.L. McArdle (Wendy); D. Hadley (David); M.J. Brown (Morris); J. Connell (John); A. Hingorani (Aroon); I.N.M. Day (Ian); D.A. Lawlor (Debbie); J.P. Beilby (John); R.W. Lawrence (Robert); R. Clarke; J. Hopewell; H. Ongen (Halit); A.W. Dreisbach (Albert); Y. Li (Yali); J. Hunter Young; J.C. Bis (Joshua); M. Kähönen (Mika); J. Viikari (Jorma); N.R. Lee (Nanette); M-H. Chen (Ming-Huei); M. Olden (Matthias); C. Pattaro (Cristian); J.A. Hoffman Bolton (Judith); A. Köttgen (Anna); S.M. Bergmann (Sven); V. Mooser (Vincent); N. Chaturvedi (Nish); T.M. Frayling (Timothy); M. Islam (Muhammad); T.H. Jafar (Tazeen); S.R. Kulkarni (Smita); S.R. Bornstein (Stefan); J. Gräßler (Jürgen); L. Groop (Leif); B.F. Voight (Benjamin); J. Kettunen (Johannes); P. Howard (Philip); A. Taylor (Andrew); S. Guarrera (Simonetta); F. Ricceri (Fulvio); V. Emilsson (Valur); A.S. Plump (Andrew); K-T. Khaw (Kay-Tee); A.B. Weder (Alan); S.C. Hunt (Steven); Y.V. Sun (Yan); R.N. Bergman (Richard); F.S. Collins (Francis); L.L. Bonnycastle (Lori); L.J. Scott (Laura); H.M. Stringham (Heather); L. Peltonen (Leena Johanna); M. Perola (Markus); E. Vartiainen (Erkki); S.-M. Brand; J.A. Staessen (Jan); Y.A. Wang (Ying); P.R. Burton (Paul); M. Soler Artigas (Maria); Y. Dong (Yanbin); H. Snieder (Harold); H. Zhu (Haidong); K. Lohman (Kurt); M.E. Rudock (Megan); S.R. Heckbert (Susan); K.L. Wiggins (Kerri); A. Doumatey (Ayo); D. Shriner (Daniel); G. Veldre (Gudrun); M. Viigimaa (Margus); S. Kinra (Sanjay); D. Prabhakaran (Dorairaj); V. Tripathy (Vikal); C.D. Langefeld (Carl); A. Rosengren (Annika); D.S. Thelle (Dag); A. Maria Corsi (Anna); A. Singleton (Andrew); T. Forrester (Terrence); G. Hilton (Gina); C.A. McKenzie (Colin); T. Salako (Tunde); N. Iwai (Naoharu); Y. Kita (Yoshikuni); T. Ogihara (Toshio); T. Ohkubo (Takayoshi); T. Okamura (Tomonori); H. Ueshima (Hirotsugu); S. Umemura (Satoshi); S. Eyheramendy (Susana); T. Meitinger (Thomas); H.E. Wichmann (Heinz Erich); Y. Shin Cho (Yoon); H.-L. Kim; J.S. Sehmi (Joban); B. Hedblad (Bo); P. Nilsson (Peter); G. Davey-Smith (George); A. Wong (Andrew); N. Narisu (Narisu); A. Stancáková (Alena); L.J. Raffel (Leslie); J. Yao (Jie); S. Kathiresan (Sekar); C.J. O'Donnell (Christopher); S.M. Schwartz (Stephen); M.A. Ikram (Arfan); W.T. Longstreth Jr; T.H. Mosley (Thomas); S. Seshadri (Sudha); N.R.G. Shrine (Nick); L.V. Wain (Louise); M.A. Morken (Mario); A.J. Swift (Amy); J. Laitinen (Jaana); I. Prokopenko (Inga); P. Zitting (Paavo); S.E. Humphries (Steve); J. Danesh (John); A. Rasheed (Asif); A. Goel (Anuj); A. Hamsten (Anders); H. Watkins (Hugh); W.H. van Gilst (Wiek); C.S. Janipalli (Charles); K. Radha Mani; C. Yajnik (Chittaranjan); A. Hofman (Albert); F.U.S. Mattace Raso (Francesco); B.A. Oostra (Ben); A. Demirkan (Ayşe); A.J. Isaacs (Aaron); F. Rivadeneira Ramirez (Fernando); E. Lakatta (Edward); M. Orrù (Marco); A. Scuteri (Angelo); M. Ala-Korpela (Mika); A.J. Kangas (Antti); L.-P. Lyytikäinen (Leo-Pekka); P. Soininen (Pasi); T. Tukiainen (Taru); P. Würtz (Peter); R. Twee-Hee Ong (Rick); M. Dörr (Marcus); H.K. Kroemer (Heyo); U. Völker (Uwe); H. Völzke (Henry); P. Galan (Pilar); S. Hercberg (Serge); G.M. Lathrop (Mark); D. Zelenika (Diana); P. Deloukas (Panagiotis); M. Mangino (Massimo); T.D. Spector (Timothy); G. Zhai (Guangju); J.F. Meschia (James F.); M.A. Nalls (Michael); P. Sharma (Pankaj); J. Terzic (Janos); M.V. Kranthi Kumar; M. Denniff (Matthew); E. Zukowska-Szczechowska (Ewa); L.E. Wagenknecht (Lynne); F. Gerald R. Fowkes; F.J. Charchar (Fadi); P.E.H. Schwarz (Peter); C. Hayward (Caroline); X. Guo (Xiuqing); C. Rotimi (Charles); M.L. Bots (Michiel); N.J. Samani (Nilesh); O. Polasek (Ozren); P.J. Talmud (Philippa); F. Nyberg (Fredrik); D. Kuh (Diana); M. Laan (Maris); K. Hveem (Kristian); Y.T. van der Schouw (Yvonne); J.P. Casas (Juan); K.L. Mohlke (Karen); P. Vineis (Paolo); O. Raitakari (Olli); S.K. Ganesh (Santhi); E. Shyong Tai; M. Laakso (Markku); D.C. Rao (Dabeeru C.); T.B. Harris (Tamara); R.W. Morris (Richard); A. Dominiczak (Anna); M. Kivimaki (Mika); M. Marmot (Michael); T. Miki (Tetsuro); D. Saleheen; G.R. Chandak (Giriraj); J. Coresh (Josef); G. Navis (Gerjan); V. Salomaa (Veikko); B.-G. Han; J.S. Kooner (Jaspal); O. Melander (Olle); P.M. Ridker (Paul); S. Bandinelli (Stefania); U. Gyllensten (Ulf); A.F. Wright (Alan); J.F. Wilson (James); L. Ferrucci (Luigi); M. Farrall (Martin); J. Tuomilehto (Jaakko); P.P. Pramstaller (Peter Paul); R. Elosua (Roberto); N. Soranzo (Nicole); E.J.G. Sijbrands (Eric); D. Altshuler (David); R.J.F. Loos (Ruth); A.R. Shuldiner (Alan); C. Gieger (Christian); P. Meneton (Pierre); A.G. Uitterlinden (André); N.J. Wareham (Nick); V. Gudnason (Vilmundur); J.I. Rotter (Jerome); R. Rettig (Rainer); M. Uda (Manuela); D.P. Strachan (David); J.C.M. Witteman (Jacqueline); A.L. Hartikainen; J.S. Beckmann (Jacques); E.A. Boerwinkle (Eric); J. Erdmann (Jeanette); R.S. Vasan (Ramachandran Srini); M. Boehnke (Michael); M.G. Larson (Martin); M.R. Järvelin; B.M. Psaty (Bruce); P. Tikka-Kleemola (Päivi); C. Newton-Cheh (Christopher); P. Elliott (Paul); D. Levy (Daniel); M. Caulfield (Mark); G.R. Abecasis (Gonçalo); L.S. Adair (Linda); S.J.L. Bakker (Stephan); I.E. Barroso (Inês)

    2011-01-01

    textabstractBlood pressure is a heritable trait influenced by several biological pathways and responsive to environmental stimuli. Over one billion people worldwide have hypertension (≥140mmg Hg systolic blood pressure ≥90mmg Hg diastolic blood pressure). Even small increments in blood pressure are

  19. Mercury (Hg) exposure and its effects on Saudi breastfed infant's neurodevelopment.

    Science.gov (United States)

    Al-Saleh, Iman; Nester, Michael; Abduljabbar, Mai; Al-Rouqi, Reem; Eltabache, Chafica; Al-Rajudi, Tahreer; Elkhatib, Rola

    2016-01-01

    This cross-sectional study analyzed mercury (Hg) levels in healthy Saudi mothers and their infants (age 3-12 months) and examined the influence of Hg on the infants' neurodevelopment using screening tools, such as the Denver Developmental Screening Test II (DDST-II) and Parents' Evaluation of Developmental Status (PEDS). A total of 944 mothers and their 944 infants were recruited from 57 Primary Health Care Centers (PHCCs) in Riyadh. The total Hg (THg) levels were measured in the mothers' and infants' urine (UTHg-M and UTHg-I) and hair (HTHg-M and HTHg-I) samples and in the breast milk and mothers' blood. Methylmercury (MeHg) levels were determined in hair samples from the mothers (MeHg-M) and infants (MeHg-I). Only 40.1% of the infants were breast-fed when enrolled, and 59.9% had stopped breastfeeding. Only 1.8% of the mothers and 0.3% of the infants had MeHg levels above the Environmental Proection Agency (EPA) reference dose (1 μg/g), with low medians of 0.132 and 0.091 μg/g dw, respectively, but the MeHg levels were significantly associated with infant DDST-II performance. The levels of corrected UTHg-M for creatinine (Cr), HTHg-M, HTHg-I, and HMeHg-M, however, displayed an association with infant PEDS performance. The medians and percentage of the tested population that exceeded the recommended limits for Hg in urine and hair set by the World Health Organization (5 μg/g Cr) and EPA (1 μg/g) were 0.695 μg/g Cr and 3% UTHg, 0.118 μg/g dw and 4.1% HTHg-M, 0.101 μg/g dw and 2.8% HTHg-I, and 0.132 μg/g dw and 1.8% HMeHg-M. Our study provides evidence of an association between some Hg measures and delays in infant neurodevelopment, despite their low levels and regardless of the infant's breastfeeding status. The results are of potential concern, because delayed psychomotor or mental performance in infants could be an indicator of later neurocognitive development in children, which may persist into adulthood, as shown in other studies. The absence of local

  20. Colloid osmotic pressure in decompensated cirrhosis. A 'mirror image' of portal venous hypertension

    DEFF Research Database (Denmark)

    Henriksen, J H

    1985-01-01

    Colloid osmotic pressure in plasma (IIP) and ascitic fluid (IIA) and hydrostatic pressures in the hepatoportal system were measured simultaneously in 20 patients with decompensated cirrhosis. IIP was significantly decreased (mean, 21 mm Hg, versus normal, 30 mm Hg; P less than 0.01), and IIA...... was significantly below that of plasma (average, 25% of IIP; P less than 0.01). Portal pressure (transmural), determined as wedged hepatic venous minus inferior vena caval pressure (WHV--IVCP), was significantly increased (mean, 18 mm Hg, versus normal, 3 mm Hg; P less than 0.01) and inversely correlated to IIA...

  1. Comparison study of upper arm and forearm non-invasive blood pressures in adult Emergency Department patients.

    Science.gov (United States)

    Schimanski, Karen; Jull, Andrew; Mitchell, Nancy; McLay, Jessica

    2014-12-01

    Forearm blood pressures have been suggested as an alternative site to measure blood pressures when the upper arm is unavailable. However there is little evidence utilising clinical populations to support this substitution. To determine agreement between blood pressures measured in the left upper arm and forearm using a singular oscillometric non-invasive device in adult Emergency Department patients. The secondary objective was to explore the relationship of blood pressure differences with age, sex, ethnicity, smoking history and obesity. Single centre comparison study. Adult Emergency Department, Tertiary Trauma Centre. Forty-four participants who met inclusion/exclusion criteria selected sequentially from the Emergency Department arrival board. A random assignment of order of measurement for left upper arm and forearm blood pressures was utilised. Participants were eligible if they were aged 18 years or older, had been assigned an Australasian Triage Scale code of 2, 3, 4, or 5, were able to consent, and able to have blood pressures measured on their left arm whilst lying at a 45° angle. The Bland-Altman method of statistical analysis was used, with the level of agreement for clinical acceptability for the systolic, diastolic and mean arterial pressure defined as ±10 mmHg. The forearm measure overestimated systolic (mean difference 2.2 mmHg, 95% limits of agreement ±19 mmHg), diastolic (mean difference 3.4 mmHg, 95% limits of agreement ±14.4 mmHg), and mean arterial pressures (mean difference 4.1 mmHg, 95% limits of agreement ±13.7 mmHg). The systolic measure was not significantly different from zero. Evidence of better agreement was found with upper arm/forearm systolic measures below 140 mmHg compared to systolic measures above 140 mmHg using the Levene's test (p=0.002, F-statistic=11.09). Blood pressure disparity was not associated with participant characteristics. Forearm measures cannot routinely replace upper arm measures for blood pressure measurement

  2. Chronologically matched toenail-Hg to hair-Hg ratio: temporal analysis within the Japanese community (U.S.

    Directory of Open Access Journals (Sweden)

    Hinners Thomas

    2012-10-01

    Full Text Available Abstract Background Toenail-Hg levels are being used as a marker of methylmercury (MeHg exposure in efforts to associate exposure with effects such as cardiovascular disease. There is a need to correlate this marker with more established biomarkers that presently underlie existing dose–response relationships in order to compare these relationships across studies. Methods As part of the Arsenic Mercury Intake Biometric Study, toenail clippings were collected at three time points over a period of one year amongst females from within the population of Japanese living near Puget Sound in Washington State (US. Variability in temporal intra-individual toenail-Hg levels was examined and chronologically matched hair and toenail samples were compared to more accurately define the toxicokinetic variability of Hg levels observed between the two compartments. Results Mean toenail-Hg values (n=43 for the 1st, 2nd and 3rd visits were 0.60, 0.60 and 0.56 ng/mg. Correlations were as follows: r=0.92 between 1st and 2nd clinic visits, r=0.75 between 1st and 3rd visits and r=0.87 between 2nd and 3rd visits. With few exceptions, toenail-Hg values from any visit were within 50-150% of the individual’s mean toenail-Hg level. Nearly all participants had less than a two-fold change in toenail-Hg levels across the study period. A regression model of the relationship between toenail-Hg and hair-Hg (n = 41 levels representing the same time period of exposure, gave a slope (Hg ng/mg of 2.79 for hair relative to toenail (r=0.954. Conclusions A chronologically matched hair-Hg to toenail-Hg ratio has been identified within a population that consumes fish regularly and in quantity. Intra-individual variation in toenail-Hg levels was less than two-fold and may represent dietary-based fluctuations in body burden for individuals consuming various fish species with different contaminant levels. The chronologically matched ratio will be useful for relating MeHg exposure and

  3. Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Yi, Jun; Wan, Yi; Pan, Feng; Yu, Xiaorong; Zhao, Huadong; Shang, Fujun; Xu, Yongyong

    2011-08-01

    The validation of sphygmomanometer is important in accurate blood pressure measurement. This study presents the validation results by the Medipro MediCare 100f upper arm blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. A total of 99 couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The device produced 73, 93, and 98 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 79, 93, and 96 for diastolic blood pressure (DBP), respectively. The mean standard deviation device-observer difference was 1.4 ± 5.2 mmHg for SBP and 0.02±5.8 mmHg for DBP. The number of participants with two or three of the device-observer differences within 5 mmHg was 24 for SBP and 30 for DBP, whereas there was no participant with none of the device-observer differences within 5 mmHg. According to the results of the validation study based on the ESH-IP revision 2010, the Medipro MediCare 100f can be recommended for self-measurement in an adult population.

  4. Hg-coordination studies of oligopeptides containing cysteine, histidine and tyrosine by $^{199m}$Hg-TDPAC

    CERN Document Server

    Ctortecka, B; Mallion, S; Butz, T; Hoffmann, R

    1999-01-01

    In order to study the interaction of histidine- and tyrosine- containing peptide chains with Hg(II), the nuclear quadrupole interaction (NQI) of /sup 199m/Hg in the Hg complexes of the oligopeptides alanyl-alanyl-histidyl-alanyl-alanine-amid (AAHAA-NH /sub 2/) and alanyl-alanyl-tyrosyl-alanyl-alanine-amid (AAYAA-NH/sub 2/) was determined by time differential perturbed angular correlation and is compared with previous data on alanyl-alanyl-cysteyl-alanyl- alanyl (AACAA-OH). The /sup 199m/Hg-NQIs depend on the oligopeptide to Hg(II) stoichiometry and indicate that two-fold and four-fold coordinations occur for the bound Hg(II). (12 refs).

  5. Automated method for the determination of total arsenic and selenium in natural and drinking water by HG-AAS.

    Science.gov (United States)

    Pistón, Mariela; Silva, Javier; Pérez-Zambra, Ramiro; Dol, Isabel; Knochen, Moisés

    2012-04-01

    A multicommutated flow system was designed and evaluated for the determination of total arsenic and selenium by Hydride Generation Atomic Absorption Spectrometry (HG-AAS). It was applied to the determination of arsenic and selenium in samples of natural and drinking water. Detection limits were 0.46 and 0.08 μg l(-1) for arsenic and selenium, respectively; sampling frequency was 120 samples h(-1) for arsenic and 160 samples h(-1) for selenium. Linear ranges found were 1.54-10 μg l(-1) (R = 0.999) for arsenic and 0.27-27 μg l(-1) (R = 0.999) for selenium. Accuracy was evaluated by spiking various water samples and using a reference material. Recoveries were in the range 95-116%. Analytical precision (s ( r ) (%), n = 10) was 6% for both elements. Compared with the Standard Methods, APHA, 3114B manual method, the system consumes at least 10 times less sample per determination, and the quantities of acid and reducing agent used are significantly lower with a reduction in the generation of pollutants and waste. As an additional advantage, the system is very fast, efficient and environmentally friendly for monitoring total arsenic and selenium levels in waters.

  6. Genetic variants in novel pathways influence blood pressure and cardiovascular disease risk

    NARCIS (Netherlands)

    Ehret, Georg B.; Munroe, Patricia B.; Rice, Kenneth M.; Bochud, Murielle; Johnson, Andrew D.; Chasman, Daniel I.; Smith, Albert V.; Tobin, Martin D.; Verwoert, Germaine C.; Hwang, Shih-Jen; Pihur, Vasyl; Vollenweider, Peter; O'Reilly, Paul F.; Amin, Najaf; Bragg-Gresham, Jennifer L.; Teumer, Alexander; Glazer, Nicole L.; Launer, Lenore; Zhao, Jing Hua; Aulchenko, Yurii; Heath, Simon; Sõber, Siim; Parsa, Afshin; Luan, Jian'an; Arora, Pankaj; Dehghan, Abbas; Zhang, Feng; Lucas, Gavin; Hicks, Andrew A.; Jackson, Anne U.; Peden, John F.; Tanaka, Toshiko; Wild, Sarah H.; Rudan, Igor; Igl, Wilmar; Milaneschi, Yuri; Parker, Alex N.; Fava, Cristiano; Chambers, John C.; Fox, Ervin R.; Kumari, Meena; Go, Min Jin; van der Harst, Pim; Kao, Wen Hong Linda; Sjögren, Marketa; Vinay, D. G.; Alexander, Myriam; Tabara, Yasuharu; Shaw-Hawkins, Sue; Whincup, Peter H.; Liu, Yongmei; Shi, Gang; Kuusisto, Johanna; Tayo, Bamidele; Seielstad, Mark; Sim, Xueling; Nguyen, Khanh-Dung Hoang; Lehtimäki, Terho; Matullo, Giuseppe; Wu, Ying; Gaunt, Tom R.; Onland-Moret, N. Charlotte; Cooper, Matthew N.; Platou, Carl G. P.; Org, Elin; Hardy, Rebecca; Dahgam, Santosh; Palmen, Jutta; Vitart, Veronique; Braund, Peter S.; Kuznetsova, Tatiana; Uiterwaal, Cuno S. P. M.; Adeyemo, Adebowale; Palmas, Walter; Campbell, Harry; Ludwig, Barbara; Tomaszewski, Maciej; Tzoulaki, Ioanna; Palmer, Nicholette D.; Aspelund, Thor; Garcia, Melissa; Chang, Yen-Pei C.; O'Connell, Jeffrey R.; Steinle, Nanette I.; Grobbee, Diederick E.; Arking, Dan E.; Kardia, Sharon L.; Morrison, Alanna C.; Hernandez, Dena; Najjar, Samer; McArdle, Wendy L.; Hadley, David; Brown, Morris J.; Connell, John M.; Hingorani, Aroon D.; Day, Ian N. M.; Lawlor, Debbie A.; Beilby, John P.; Lawrence, Robert W.; Clarke, Robert; Hopewell, Jemma C.; Ongen, Halit; Dreisbach, Albert W.; Li, Yali; Young, J. Hunter; Bis, Joshua C.; Kähönen, Mika; Viikari, Jorma; Adair, Linda S.; Lee, Nanette R.; Chen, Ming-Huei; Olden, Matthias; Pattaro, Cristian; Bolton, Judith A. Hoffman; Köttgen, Anna; Bergmann, Sven; Mooser, Vincent; Chaturvedi, Nish; Frayling, Timothy M.; Islam, Muhammad; Jafar, Tazeen H.; Erdmann, Jeanette; Kulkarni, Smita R.; Bornstein, Stefan R.; Grässler, Jürgen; Groop, Leif; Voight, Benjamin F.; Kettunen, Johannes; Howard, Philip; Taylor, Andrew; Guarrera, Simonetta; Ricceri, Fulvio; Emilsson, Valur; Plump, Andrew; Barroso, Inês; Khaw, Kay-Tee; Weder, Alan B.; Hunt, Steven C.; Sun, Yan V.; Bergman, Richard N.; Collins, Francis S.; Bonnycastle, Lori L.; Scott, Laura J.; Stringham, Heather M.; Peltonen, Leena; Perola, Markus; Vartiainen, Erkki; Brand, Stefan-Martin; Staessen, Jan A.; Wang, Thomas J.; Burton, Paul R.; Artigas, Maria Soler; Dong, Yanbin; Snieder, Harold; Wang, Xiaoling; Zhu, Haidong; Lohman, Kurt K.; Rudock, Megan E.; Heckbert, Susan R.; Smith, Nicholas L.; Wiggins, Kerri L.; Doumatey, Ayo; Shriner, Daniel; Veldre, Gudrun; Viigimaa, Margus; Kinra, Sanjay; Prabhakaran, Dorairaj; Tripathy, Vikal; Langefeld, Carl D.; Rosengren, Annika; Thelle, Dag S.; Corsi, Anna Maria; Singleton, Andrew; Forrester, Terrence; Hilton, Gina; McKenzie, Colin A.; Salako, Tunde; Iwai, Naoharu; Kita, Yoshikuni; Ogihara, Toshio; Ohkubo, Takayoshi; Okamura, Tomonori; Ueshima, Hirotsugu; Umemura, Satoshi; Eyheramendy, Susana; Meitinger, Thomas; Wichmann, H.-Erich; Cho, Yoon Shin; Kim, Hyung-Lae; Lee, Jong-Young; Scott, James; Sehmi, Joban S.; Zhang, Weihua; Hedblad, Bo; Nilsson, Peter; Smith, George Davey; Wong, Andrew; Narisu, Narisu; Stančáková, Alena; Raffel, Leslie J.; Yao, Jie; Kathiresan, Sekar; O'Donnell, Christopher J.; Schwartz, Stephen M.; Ikram, M. Arfan; Longstreth, W. T.; Mosley, Thomas H.; Seshadri, Sudha; Shrine, Nick R. G.; Wain, Louise V.; Morken, Mario A.; Swift, Amy J.; Laitinen, Jaana; Prokopenko, Inga; Zitting, Paavo; Cooper, Jackie A.; Humphries, Steve E.; Danesh, John; Rasheed, Asif; Goel, Anuj; Hamsten, Anders; Watkins, Hugh; Bakker, Stephan J. L.; van Gilst, Wiek H.; Janipalli, Charles S.; Mani, K. Radha; Yajnik, Chittaranjan S.; Hofman, Albert; Mattace-Raso, Francesco U. S.; Oostra, Ben A.; Demirkan, Ayse; Isaacs, Aaron; Rivadeneira, Fernando; Lakatta, Edward G.; Orru, Marco; Scuteri, Angelo; Ala-Korpela, Mika; Kangas, Antti J.; Lyytikäinen, Leo-Pekka; Soininen, Pasi; Tukiainen, Taru; Würtz, Peter; Ong, Rick Twee-Hee; Dörr, Marcus; Kroemer, Heyo K.; Völker, Uwe; Völzke, Henry; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Zelenika, Diana; Deloukas, Panos; Mangino, Massimo; Spector, Tim D.; Zhai, Guangju; Meschia, James F.; Nalls, Michael A.; Sharma, Pankaj; Terzic, Janos; Kumar, M. V. Kranthi; Denniff, Matthew; Zukowska-Szczechowska, Ewa; Wagenknecht, Lynne E.; Fowkes, F. Gerald R.; Charchar, Fadi J.; Schwarz, Peter E. H.; Hayward, Caroline; Guo, Xiuqing; Rotimi, Charles; Bots, Michiel L.; Brand, Eva; Samani, Nilesh J.; Polasek, Ozren; Talmud, Philippa J.; Nyberg, Fredrik; Kuh, Diana; Laan, Maris; Hveem, Kristian; Palmer, Lyle J.; van der Schouw, Yvonne T.; Casas, Juan P.; Mohlke, Karen L.; Vineis, Paolo; Raitakari, Olli; Ganesh, Santhi K.; Wong, Tien Y.; Tai, E. Shyong; Cooper, Richard S.; Laakso, Markku; Rao, Dabeeru C.; Harris, Tamara B.; Morris, Richard W.; Dominiczak, Anna F.; Kivimaki, Mika; Marmot, Michael G.; Miki, Tetsuro; Saleheen, Danish; Chandak, Giriraj R.; Coresh, Josef; Navis, Gerjan; Salomaa, Veikko; Han, Bok-Ghee; Zhu, Xiaofeng; Kooner, Jaspal S.; Melander, Olle; Ridker, Paul M.; Bandinelli, Stefania; Gyllensten, Ulf B.; Wright, Alan F.; Wilson, James F.; Ferrucci, Luigi; Farrall, Martin; Tuomilehto, Jaakko; Pramstaller, Peter P.; Elosua, Roberto; Soranzo, Nicole; Sijbrands, Eric J. G.; Altshuler, David; Loos, Ruth J. F.; Shuldiner, Alan R.; Gieger, Christian; Meneton, Pierre; Uitterlinden, Andre G.; Wareham, Nicholas J.; Gudnason, Vilmundur; Rotter, Jerome I.; Rettig, Rainer; Uda, Manuela; Strachan, David P.; Witteman, Jacqueline C. M.; Hartikainen, Anna-Liisa; Beckmann, Jacques S.; Boerwinkle, Eric; Vasan, Ramachandran S.; Boehnke, Michael; Larson, Martin G.; Järvelin, Marjo-Riitta; Psaty, Bruce M.; Abecasis, Gonçalo R.; Chakravarti, Aravinda; Elliott, Paul; van Duijn, Cornelia M.; Newton-Cheh, Christopher; Levy, Daniel; Caulfield, Mark J.; Johnson, Toby; Tang, Hua; Knowles, Joshua; Hlatky, Mark; Fortmann, Stephen; Assimes, Themistocles L.; Quertermous, Thomas; Go, Alan; Iribarren, Carlos; Absher, Devin; Risch, Neil; Myers, Richard; Sidney, Steven; Ziegler, Andreas; Schillert, Arne; Bickel, Christoph; Sinning, Christoph; Rupprecht, Hans J.; Lackner, Karl; Wild, Philipp; Schnabel, Renate; Blankenberg, Stefan; Zeller, Tanja; Münzel, Thomas; Perret, Claire; Cambien, Francois; Tiret, Laurence; Nicaud, Viviane; Proust, Carole; Uitterlinden, Andre; van Duijn, Cornelia; Whitteman, Jaqueline; Cupples, L. Adrienne; Demissie-Banjaw, Serkalem; Ramachandran, Vasan; Smith, Albert; Folsom, Aaron; Morrison, Alanna; Chen, Ida Yii-Der; Bis, Joshua; Volcik, Kelly; Rice, Kenneth; Taylor, Kent D.; Marciante, Kristin; Smith, Nicholas; Glazer, Nicole; Heckbert, Susan; Harris, Tamara; Lumley, Thomas; Kong, Augustine; Thorleifsson, Gudmar; Thorgeirsson, Gudmundur; Holm, Hilma; Gulcher, Jeffrey R.; Stefansson, Kari; Andersen, Karl; Gretarsdottir, Solveig; Thorsteinsdottir, Unnur; Preuss, Michael; Schreiber, Stefan; König, Inke R.; Lieb, Wolfgang; Hengstenberg, Christian; Schunkert, Heribert; Fischer, Marcus; Grosshennig, Anika; Medack, Anja; Stark, Klaus; Linsel-Nitschke, Patrick; Bruse, Petra; Aherrahrou, Zouhair; Peters, Annette; Loley, Christina; Willenborg, Christina; Nahrstedt, Janja; Freyer, Jennifer; Gulde, Stephanie; Doering, Angela; Meisinger, Christina; Klopp, Norman; Illig, Thomas; Meinitzer, Andreas; Tomaschitz, Andreas; Halperin, Eran; Dobnig, Harald; Scharnagl, Hubert; Kleber, Marcus; Laaksonen, Reijo; Pilz, Stefan; Grammer, Tanja B.; Stojakovic, Tatjana; Renner, Wilfried; März, Winfried; Böhm, Bernhard O.; Winkelmann, Bernhard R.; Winkler, Karl; Hoffmann, Michael M.; Siscovick, David S.; Musunuru, Kiran; Barbalic, Maja; Guiducci, Candace; Burtt, Noel; Gabriel, Stacey B.; Stewart, Alexandre F. R.; Wells, George A.; Chen, Li; Jarinova, Olga; Roberts, Robert; McPherson, Ruth; Dandona, Sonny; Pichard, Augusto D.; Rader, Daniel J.; Devaney, Joe; Lindsay, Joseph M.; Kent, Kenneth M.; Qu, Liming; Satler, Lowell; Burnett, Mary Susan; Li, Mingyao; Reilly, Muredach P.; Wilensky, Robert; Waksman, Ron; Epstein, Stephen; Matthai, William; Knouff, Christopher W.; Waterworth, Dawn M.; Hakonarson, Hakon H.; Walker, Max C.; Hall, Alistair S.; Balmforth, Anthony J.; Wright, Benjamin J.; Nelson, Chris; Thompson, John R.; Ball, Stephen G.; Felix, Janine F.; Demissie, Serkalem; Loehr, Laura R.; Rosamond, Wayne D.; Folsom, Aaron R.; Benjamin, Emelia; Aulchenko, Yurii S.; Haritunians, Talin; Couper, David; Murabito, Joanne; Wang, Ying A.; Stricker, Bruno H.; Gottdiener, John S.; Chang, Patricia P.; Willerson, James T.; Köttgen, A.; Pattaro, C.; Böger, C. A.; Fuchsberger, C.; Olden, M.; Glazer, N. L.; Parsa, A.; Gao, X.; Yang, Q.; Smith, A. V.; O'Connell, J. R.; Li, M.; Schmidt, H.; Tanaka, T.; Isaacs, A.; Ketkar, S.; Hwang, S. J.; Johnson, A. D.; Dehghan, A.; Teumer, A.; Paré, G.; Atkinson, E. J.; Zeller, T.; Lohman, K.; Cornelis, M. C.; Probst-Hensch, N. M.; Kronenberg, F.; Tönjes, A.; Hayward, C.; Aspelund, T.; Eiriksdottir, G.; Launer, L. J.; Harris, T. B.; Rampersaud, E.; Mitchell, B. D.; Arking, D. E.; Boerwinkle, E.; Struchalin, M.; Cavalieri, M.; Singleton, A.; Giallauria, F.; Metter, J.; de Boer, J.; Haritunians, T.; Lumley, T.; Siscovick, D.; Psaty, B. M.; Zillikens, M. C.; Oostra, B. A.; Feitosa, M.; Province, M.; de Andrade, M.; Turner, S. T.; Schillert, A.; Ziegler, A.; Wild, P. S.; Schnabel, R. B.; Wilde, S.; Munzel, T. F.; Leak, T. S.; Illig, T.; Klopp, N.; Meisinger, C.; Wichmann, H. E.; Koenig, W.; Zgaga, L.; Zemunik, T.; Kolcic, I.; Minelli, C.; Hu, F. B.; Johansson, A.; Igl, W.; Zaboli, G.; Wild, S. H.; Wright, A. F.; Campbell, H.; Ellinghaus, D.; Schreiber, S.; Aulchenko, Y. S.; Felix, J. F.; Rivadeneira, F.; Uitterlinden, A. G.; Hofman, A.; Imboden, M.; Nitsch, D.; Brandstätter, A.; Kollerits, B.; Kedenko, L.; Mägi, R.; Stumvoll, M.; Kovacs, P.; Boban, M.; Campbell, S.; Endlich, K.; Völzke, H.; Kroemer, H. K.; Nauck, M.; Völker, U.; Polasek, O.; Vitart, V.; Badola, S.; Parker, A. N.; Ridker, P. M.; Kardia, S. L.; Blankenberg, S.; Liu, Y.; Curhan, G. C.; Franke, A.; Rochat, T.; Paulweber, B.; Prokopenko, I.; Wang, W.; Gudnason, V.; Shuldiner, A. R.; Coresh, J.; Schmidt, R.; Ferrucci, L.; Shlipak, M. G.; van Duijn, C. M.; Borecki, I.; Krämer, B. K.; Rudan, I.; Gyllensten, U.; Wilson, J. F.; Witteman, J. C.; Pramstaller, P. P.; Rettig, R.; Hastie, N.; Chasman, D. I.; Kao, W. H.; Heid, I. M.; Fox, C. S.; Vasan, R. S.; Lieb, W.; Felix, S. B.; Watzinger, N.; Larson, M. G.; Smith, N. L.; Grosshennig, A.; Kathiresan, S.; König, I. R.; Homuth, G.; Aragam, J.; Bis, J. C.; Erdmann, J.; Dörr, M.; Zweiker, R.; Lind, L.; Rodeheffer, R. J.; Greiser, K. H.; Levy, D.; Deckers, J. W.; Stritzke, J.; Lackner, K. J.; Ingelsson, E.; Kullo, I.; Haerting, J.; O'Donnell, C. J.; Heckbert, S. R.; Stricker, B. H.; Reffelmann, T.; Redfield, M. M.; Werdan, K.; Mitchell, G. F.; Rice, K.; Arnett, D. K.; Gottdiener, J. S.; Meitinger, T.; Blettner, M.; Friedrich, N.; Wang, T. J.; Benjamin, E. J.; Rotter, J. I.; Schunkert, H.; Chambers, J. C.; Zhang, W.; Lord, G. M.; van der Harst, P.; Lawlor, D. A.; Sehmi, J. S.; Gale, D. P.; Wass, M. N.; Ahmadi, K. R.; Bakker, S. J.; Beckmann, J.; Bilo, H. J.; Bochud, M.; Brown, M. J.; Caulfield, M. J.; Connell, J. M.; Cook, H. T.; Cotlarciuc, I.; Davey Smith, G.; de Silva, R.; Deng, G.; Devuyst, O.; Dikkeschei, L. D.; Dimkovic, N.; Dockrell, M.; Dominiczak, A.; Ebrahim, S.; Eggermann, T.; Farrall, M.; Floege, J.; Forouhi, N. G.; Gansevoort, R. T.; Han, X.; Hedblad, B.; Homan van der Heide, J. J.; Hepkema, B. G.; Hernandez-Fuentes, M.; Hypponen, E.; Johnson, T.; de Jong, P. E.; Kleefstra, N.; Lagou, V.; Lapsley, M.; Li, Y.; Loos, R. J.; Luan, J.; Luttropp, K.; Maréchal, C.; Melander, O.; Munroe, P. B.; Nordfors, L.; Peltonen, L.; Penninx, B. W.; Perucha, E.; Pouta, A.; Roderick, P. J.; Ruokonen, A.; Samani, N. J.; Sanna, S.; Schalling, M.; Schlessinger, D.; Schlieper, G.; Seelen, M. A.; Sjögren, M.; Smit, J. H.; Snieder, H.; Soranzo, N.; Spector, T. D.; Stenvinkel, P.; Sternberg, M. J.; Swaminathan, R.; Ubink-Veltmaat, L. J.; Uda, M.; Vollenweider, P.; Wallace, C.; Waterworth, D.; Zerres, K.; Waeber, G.; Wareham, N. J.; Maxwell, P. H.; McCarthy, M. I.; Jarvelin, M. R.; Mooser, V.; Abecasis, G. R.; Lightstone, L.; Scott, J.; Navis, G.; Elliott, P.; Kooner, J. S.

    2011-01-01

    Blood pressure is a heritable trait influenced by several biological pathways and responsive to environmental stimuli. Over one billion people worldwide have hypertension (≥140 mm Hg systolic blood pressure or  ≥90 mm Hg diastolic blood pressure). Even small increments in blood pressure are

  7. Detailed Assessment of the Kinetics of Hg-Cell Association, Hg Methylation, and Methylmercury Degradation in Several Desulfovibrio Species

    Science.gov (United States)

    Graham, Andrew M.; Bullock, Allyson L.; Maizel, Andrew C.; Elias, Dwayne A.

    2012-01-01

    The kinetics of inorganic Hg [Hg(II)i] association, methylation, and methylmercury (MeHg) demethylation were examined for a group of Desulfovibrio species with and without MeHg production capability. We employed a detailed method for assessing MeHg production in cultures, including careful control of medium chemistry, cell density, and growth phase, plus mass balance of Hg(II)i and MeHg during the assays. We tested the hypothesis that differences in Hg(II)i sorption and/or uptake rates drive observed differences in methylation rates among Desulfovibrio species. Hg(II)i associated rapidly and with high affinity to both methylating and nonmethylating species. MeHg production by Hg-methylating strains was rapid, plateauing after ∼3 h. All MeHg produced was rapidly exported. We also tested the idea that all Desulfovibrio species are capable of Hg(II)i methylation but that rapid demethylation masks its production, but we found this was not the case. Therefore, the underlying reason why MeHg production capability is not universal in the Desulfovibrio is not differences in Hg affinity for cells nor differences in the ability of strains to degrade MeHg. However, Hg methylation rates varied substantially between Hg-methylating Desulfovibrio species even in these controlled experiments and after normalization to cell density. Thus, biological differences may drive cross-species differences in Hg methylation rates. As part of this study, we identified four new Hg methylators (Desulfovibrio aespoeensis, D. alkalitolerans, D. psychrotolerans, and D. sulfodismutans) and four nonmethylating species (Desulfovibrio alcoholivorans, D. tunisiensis, D. carbinoliphilus, and D. piger) in our ongoing effort to generate a library of strains for Hg methylation genomics. PMID:22885751

  8. Evidence of Hg-chain formation in HgxTiS2: a 199mHg-TDPAC study

    International Nuclear Information System (INIS)

    Troeger, W.; Butz, T.; Ouvrard, G.

    1993-01-01

    We determined the 199m Hg nuclear quadrupole interaction in the ''misfit'' or ''superstoichiometric'' compound Hg x TiS 2 by time differential perturbed angular correlation. A unique Hg-site with ν Q = 511(1) MHz and η = 0.410(4) was observed, irrespective of the Hg-uptake (2/3 ≤ x ≤ 4/3). We propose a model of Hg-Hg zig-zag chains which accounts for these observations as well as for the X-ray diffraction data. (orig.)

  9. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: The CoCo trial

    Directory of Open Access Journals (Sweden)

    Senn Oliver

    2010-04-01

    Full Text Available Abstract Background Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Objective Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Outcome Primary outcome: Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary. Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries. Methods/Design Randomised controlled study. Population: 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system. Expected results/conclusion The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range ≤ 140/≤ 90 mmHg, yellow: blood pressure >140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg lead to better self-monitoring compared with the conventional (non-colour-coded blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. Trial registration ClinicalTrials.gov ID NCT01013467

  10. Effects of external pressure loading on human skin blood flow measured by 133Xe clearance

    International Nuclear Information System (INIS)

    Holloway, G.A. Jr.; Daly, C.H.; Kennedy, D.; Chimoskey, J.

    1976-01-01

    Forearm skin blood flow was measured during external pressure loading in normal human subjects using 133 Xe washout from intracutaneous injection sites. Pressures ranging between 5 and 150 mmHg were applied through a 3-cm-diameter disc placed over the site of flow determination. The pressure was maintained constant by a servo-controlled loading mechanism. Flow decreased with pressures from 5 to 10 and 30 to 150 mmHg, but remained constant with pressures from 10 to 30 mmHg. Reactive hyperemia occurred following removal of pressures of 90 mmHg or greater, but did not occur following removal of lower pressures. The pressure-flow curve for parasacral skin of paraplegic subjects closely paralleled the pressure-flow curve of normal skin at pressures tested: 5 to 15 mmHg. These data are interpreted to demonstrate autoregulation of skin blood flow. Autoregulation in parasacral skin of paraplegic subjects suggests a peripheral mechanism. The occurrence of hyperemia at pressures which exceed the ability of skin to autoregulate suggests that both autoregulation and post occlusion hyperemia may have the same mechanism

  11. Automated electronic monitoring of circuit pressures during continuous renal replacement therapy: a technical report.

    Science.gov (United States)

    Zhang, Ling; Baldwin, Ian; Zhu, Guijun; Tanaka, Aiko; Bellomo, Rinaldo

    2015-03-01

    Automated electronic monitoring and analysis of circuit pressures during continuous renal replacement therapy (CRRT) has the potential to predict failure and allow intervention to optimise function. Current CRRT machines can measure and store pressure readings for downloading into databases and for analysis. We developed a procedure to obtain such data at intervals of 1 minute and analyse them using the Prismaflex CRRT machine, and we present an example of such analysis. We obtained data on pressures obtained at intervals of 1 minute in a patient with acute kidney injury and sepsis treated with continuous haemofiltration at 2 L/hour of ultrafiltration and a blood flow of 200 mL/minute. Data analysis identified progressive increases in transmembrane pressure (TMP) and prefilter pressure (PFP) from time 0 until 33 hours or clotting. TMP increased from 104 mmHg to 313 mmHg and PFP increased from from 131 mmHg to 185 mmHg. Effluent pressure showed a progressive increase in the negative pressure applied to achieve ultrafiltration from 0 mmHg to -168 mmHg. The inflection point for such changes was also identified. Blood pathway pressures for access and return remained unchanged throughout. Automated electronic monitoring of circuit pressure during CRRT is possible and provides useful information on the evolution of circuit clotting.

  12. A Theoretical Study of the Oxidation of Hg0 to HgBr2 in the Troposphere

    DEFF Research Database (Denmark)

    Goodsite, M. E.; Plane, J. M C; Skov, H.

    2004-01-01

    The oxidation of elemental mercury (Hg0) to the divalent gaseous mercury dibromide (HgBr2) has been proposed to account for the removal of Hg0 during depletion events in the springtime Arctic. The mechanism of this process is explored in this paper by theoretical calculations of the relevant rate...... coefficients. Rice-Ramsberger-Kassel-Marcus (RRKM) theory, together with ab initio quantum calculations where required, are used to estimate the following: recombination rate coefficients of Hg with Br, I, and O; the thermal dissociation rate coefficient of HgBr; and the recombination rate coefficients of Hg......Br with Br, I, OH, and O2. A mechanism based on the initial recombination of Hg with Br, followed by the addition of a second radical (Br, I, or OH) in competition with thermal dissociation of HgBr, is able to account for the observed rate of Hg 0 removal, both in Arctic depletion events and at lower...

  13. Combined effect of blood pressure and total cholesterol levels on long-term risks of subtypes of cardiovascular death: Evidence for Cardiovascular Prevention from Observational Cohorts in Japan.

    Science.gov (United States)

    Satoh, Michihiro; Ohkubo, Takayoshi; Asayama, Kei; Murakami, Yoshitaka; Sakurai, Masaru; Nakagawa, Hideaki; Iso, Hiroyasu; Okayama, Akira; Miura, Katsuyuki; Imai, Yutaka; Ueshima, Hirotsugu; Okamura, Tomonori

    2015-03-01

    No large-scale, longitudinal studies have examined the combined effects of blood pressure (BP) and total cholesterol levels on long-term risks for subtypes of cardiovascular death in an Asian population. To investigate these relationships, a meta-analysis of individual participant data, which included 73 916 Japanese subjects (age, 57.7 years; men, 41.1%) from 11 cohorts, was conducted. During a mean follow-up of 15.0 years, deaths from coronary heart disease, ischemic stroke, and intraparenchymal hemorrhage occurred in 770, 724, and 345 cases, respectively. Cohort-stratified Cox proportional hazard models were used. After stratifying the participants by 4 systolic BP ×4 total cholesterol categories, the group with systolic BP ≥160 mm Hg with total cholesterol ≥5.7 mmol/L had the greatest risk for coronary heart disease death (adjusted hazard ratio, 4.39; Pdeath, and total cholesterol was inversely associated with intraparenchymal hemorrhage, but no significant interactions between BP and total cholesterol were observed for stroke. High BP and high total cholesterol can synergistically increase the risk for coronary heart disease death but not for stroke in the Asian population. © 2015 American Heart Association, Inc.

  14. Maternal-fetal distribution of mercury ( sup 203 Hg) released from dental amalgam fillings

    Energy Technology Data Exchange (ETDEWEB)

    Vimy, M.J.; Takahashi, Y.; Lorscheider, F.L. (Univ. of Calgary, Alberta (Canada))

    1990-04-01

    In humans, the continuous release of Hg vapor from dental amalgam tooth restorations is markedly increased for prolonged periods after chewing. The present study establishes a time-course distribution for amalgam Hg in body tissues of adult and fetal sheep. Under general anesthesia, five pregnant ewes had twelve occlusal amalgam fillings containing radioactive 203Hg placed in teeth at 112 days gestation. Blood, amniotic fluid, feces, and urine specimens were collected at 1- to 3-day intervals for 16 days. From days 16-140 after amalgam placement (16-41 days for fetal lambs), tissue specimens were analyzed for radioactivity, and total Hg concentrations were calculated. Results demonstrate that Hg from dental amalgam will appear in maternal and fetal blood and amniotic fluid within 2 days after placement of amalgam tooth restorations. Excretion of some of this Hg will also commence within 2 days. All tissues examined displayed Hg accumulation. Highest concentrations of Hg from amalgam in the adult occurred in kidney and liver, whereas in the fetus the highest amalgam Hg concentrations appeared in liver and pituitary gland. The placenta progressively concentrated Hg as gestation advanced to term, and milk concentration of amalgam Hg postpartum provides a potential source of Hg exposure to the newborn. It is concluded that accumulation of amalgam Hg progresses in maternal and fetal tissues to a steady state with advancing gestation and is maintained. Dental amalgam usage as a tooth restorative material in pregnant women and children should be reconsidered.

  15. Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Chen, Wan; Zeng, Zhao-Lin; Bing, Sen; Li, Lin-Yi; Wang, Rui; Wan, Yi

    2016-08-01

    The aim of the present study was to validate the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for the validation of blood pressure-measuring devices in adults was followed precisely. Systolic and diastolic blood pressure (SBP and DBP, respectively) were measured sequentially in 33 adult patients and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The device produced 78, 95 and 99 measurements within 5, 10, and 15 mmHg for SBP and 83, 96, and 99 for DBP, respectively. The average device-observer difference was -1.81±4.22 mmHg for SBP and -0.15±3.93 mmHg for DBP. All of the data were within the standards requirements to pass the testing. The Grandway MD2301 digital automatic blood pressure monitor meets the standards of the ESH-IP revision 2010 and can be recommended for self/home measurement in the general population.

  16. Genetic Polymorphisms in Glutathione (GSH- Related Genes Affect the Plasmatic Hg/Whole Blood Hg Partitioning and the Distribution between Inorganic and Methylmercury Levels in Plasma Collected from a Fish-Eating Population

    Directory of Open Access Journals (Sweden)

    Andréia Ávila Soares de Oliveira

    2014-01-01

    Full Text Available This study aims to evaluate the effects of polymorphisms in glutathione (GSH- related genes (GSTM1, GSTT1, GSTP1, GCLM, and GCLC in the distribution of Hg in the blood compartments in humans exposed to methylmercury (MeHg. Subjects (n=88, exposed to MeHg from fish consumption, were enrolled in the study. Hg species in the plasma compartment were determined by LC-ICP-MS, whereas genotyping was performed by PCR assays. Mean total Hg levels in plasma (THgP and whole blood (THgB were 10±4.2 and 37±21, whereas mean evels of plasmatic MeHg (MeHgP, inorganic Hg (IHgP, and HgP/HgB were 4.3±2.9, 5.8±2.3 µg/L, and 0.33±0.15, respectively. GSTM1 and GCLC polymorphisms influence THgP and MeHgP (multivariate analyses, P<0.050. Null homozygotes for GSTM1 showed higher THgP and MeHgP levels compared to subjects with GSTM1 (THgP β=0.22, P=0.035; MeHgP β=0.30, P=0.050 and persons carrying at least one T allele for GCLC had significant higher MeHgP (β=0.59, P=0.046. Also, polymorphic GCLM subjects had lower THgP/THgB than those with the nonvariant genotype. Taken together, data of this study suggest that GSH-related polymorphisms may change the metabolism of MeHg by modifying the distribution of mercury species iin plasma compartment and the HgP/HgB partitioning.

  17. PPARγ ligands decrease hydrostatic pressure-induced platelet aggregation and proinflammatory activity.

    Directory of Open Access Journals (Sweden)

    Fang Rao

    Full Text Available Hypertension is known to be associated with platelet overactivity, but the direct effects of hydrostatic pressure on platelet function remain unclear. The present study sought to investigate whether elevated hydrostatic pressure is responsible for platelet activation and to address the potential role of peroxisome proliferator-activated receptor-γ (PPARγ. We observed that hypertensive patients had significantly higher platelet volume and rate of ADP-induced platelets aggregation compared to the controls. In vitro, Primary human platelets were cultured under standard (0 mmHg or increased (120, 180, 240 mmHg hydrostatic pressure for 18 h. Exposure to elevated pressure was associated with morphological changes in platelets. Platelet aggregation and PAC-1 (the active confirmation of GPIIb/IIIa binding were increased, CD40L was translocated from cytoplasm to the surface of platelet and soluble CD40L (sCD40L was released into the medium in response to elevated hydrostatic pressure (180 and 240 mmHg. The PPARγ activity was up-regulated as the pressure was increased from 120 mmHg to 180 mmHg. Pressure-induced platelet aggregation, PAC-1 binding, and translocation and release of CD40L were all attenuated by the PPARγ agonist Thiazolidinediones (TZDs. These results demonstrate that platelet activation and aggregation are increased by exposure to elevated pressure and that PPARγ may modulate platelet activation induced by high hydrostatic pressure.

  18. PPARγ ligands decrease hydrostatic pressure-induced platelet aggregation and proinflammatory activity.

    Science.gov (United States)

    Rao, Fang; Yang, Ren-Qiang; Chen, Xiao-Shu; Xu, Jin-Song; Fu, Hui-Min; Su, Hai; Wang, Ling

    2014-01-01

    Hypertension is known to be associated with platelet overactivity, but the direct effects of hydrostatic pressure on platelet function remain unclear. The present study sought to investigate whether elevated hydrostatic pressure is responsible for platelet activation and to address the potential role of peroxisome proliferator-activated receptor-γ (PPARγ). We observed that hypertensive patients had significantly higher platelet volume and rate of ADP-induced platelets aggregation compared to the controls. In vitro, Primary human platelets were cultured under standard (0 mmHg) or increased (120, 180, 240 mmHg) hydrostatic pressure for 18 h. Exposure to elevated pressure was associated with morphological changes in platelets. Platelet aggregation and PAC-1 (the active confirmation of GPIIb/IIIa) binding were increased, CD40L was translocated from cytoplasm to the surface of platelet and soluble CD40L (sCD40L) was released into the medium in response to elevated hydrostatic pressure (180 and 240 mmHg). The PPARγ activity was up-regulated as the pressure was increased from 120 mmHg to 180 mmHg. Pressure-induced platelet aggregation, PAC-1 binding, and translocation and release of CD40L were all attenuated by the PPARγ agonist Thiazolidinediones (TZDs). These results demonstrate that platelet activation and aggregation are increased by exposure to elevated pressure and that PPARγ may modulate platelet activation induced by high hydrostatic pressure.

  19. Prevalence of inter-arm blood pressure difference among clinical out-patients.

    Science.gov (United States)

    Sharma, Balkishan; Ramawat, Pramila

    2016-04-01

    An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (pdifferent inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.

  20. Achieved Blood Pressure and Outcomes in the Secondary Prevention of Small Subcortical Strokes Trial.

    Science.gov (United States)

    Odden, Michelle C; McClure, Leslie A; Sawaya, B Peter; White, Carole L; Peralta, Carmen A; Field, Thalia S; Hart, Robert G; Benavente, Oscar R; Pergola, Pablo E

    2016-01-01

    Studies suggest a J-shaped association between blood pressure and cardiovascular events in the setting of intensive systolic blood pressure control; whether there is a similar association with stroke remains less well established. The Secondary Prevention of Small Subcortical Strokes was a randomized trial to evaluate higher (130-149 mm Hg) versus lower (blood pressure targets in participants with recent lacunar infarcts. We evaluated the association of mean achieved blood pressure, 6 months after randomization, and recurrent stroke, major vascular events, and all-cause mortality. After a mean follow up of 3.7 years, there was a J-shaped association between achieved blood pressure and outcomes; the lowest risk was at ≈124 and 67 mm Hg systolic and diastolic blood pressure, respectively. For example, above a systolic blood pressure of 124 mm Hg, 1 standard deviation higher (11.1 mm Hg) was associated with increased mortality (adjusted hazard ratio: 1.9; 95% confidence interval: 1.4, 2.7), whereas below this level, this relationship was inverted (0.29; 0.10, 0.79), Pblood pressure of 67 mm Hg, a 1 standard deviation higher (8.2 mm Hg) was associated with an increased risk of stroke (2.2; 1.4, 3.6), whereas below this level, the association was in the opposite direction (0.34; 0.13, 0.89), P=0.02 for interaction. The lowest risk of all events occurred at a nadir of ≈120 to 128 mm Hg systolic blood pressure and 65 to 70 mm Hg diastolic blood pressure. Future studies should evaluate the impact of excessive blood pressure reduction, especially in older populations with preexisting vascular disease. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00059306. © 2015 American Heart Association, Inc.

  1. Cardiorespiratory effects of balancing PEEP with intra-abdominal pressures during laparoscopic cholecystectomy.

    Science.gov (United States)

    Kundra, Pankaj; Subramani, Yamini; Ravishankar, M; Sistla, Sarath C; Nagappa, Mahesh; Sivashanmugam, T

    2014-06-01

    Applying appropriate positive end-expiratory pressure (PEEP) to corresponding intra-abdominal pressure (IAP) can improve gas exchange during capnoperitoneum without any hemodynamic effects. A total of 75 patients were randomly allocated to group 0PEEP (n=25), group 5PEEP (n=25), and group 10PEEP (n=25) according to the level of PEEP, in whom capnoperitoneum was created with IAP of 14, 8, and 14 mm Hg, respectively. Hemodynamic and respiratory parameters were recorded up to 30 minutes after capnoperitoneum. In 0PEEP group, mean end-tidal carbon dioxide demonstrated significant rise 2 minutes after capnoperitoneum and plateaued at about 15 minutes but remained at high level for up to 30 minutes when compared with the 5PEEP and 10PEEP groups (Phigher at 30 minutes when compared with 5PEEP (37.8±2.7 mm Hg) and 10PEEP (37.2±3.9 mm Hg) groups. The oxygenation was better preserved in 5PEEP and 10PEEP groups with significantly higher PaO2/Fio2 ratio. Heart rate, mean arterial pressure, and cardiac output remained stable throughout the study in all the 3 groups. Application of appropriate PEEP corresponding to the IAP helped maintain CO2 elimination and improved oxygenation without any hemodynamic disturbance in patients undergoing laparoscopic cholecystectomy.

  2. Distinct toxicological characteristics and mechanisms of Hg2+ and MeHg in Tetrahymena under low concentration exposure.

    Science.gov (United States)

    Liu, Cheng-Bin; Qu, Guang-Bo; Cao, Meng-Xi; Liang, Yong; Hu, Li-Gang; Shi, Jian-Bo; Cai, Yong; Jiang, Gui-Bin

    2017-12-01

    Inorganic divalent mercury complexes (Hg 2+ ) and monomethylmercury complexes (MeHg) are the main mercury species in aquatic systems and their toxicity to aquatic organisms is of great concern. Tetrahymena is a type of unicellular eukaryotic protozoa located at the bottom of food chain that plays a fundamental role in the biomagnification of mercury. In this work, the dynamic accumulation properties, toxicological characteristics and mechanisms of Hg 2+ and MeHg in five Tetrahymena species were evaluated in detail. The results showed that both Hg 2+ and MeHg were ingested and exhibited inhibitory effects on the proliferation or survival of Tetrahymena species. However, the ingestion rate of MeHg was significantly higher than that of Hg 2+ . The mechanisms responsible for the toxicity of MeHg and Hg 2+ were different, although both chemicals altered mitochondrial membrane potential (MMP). MeHg disrupted the integrity of membranes while Hg 2+ had detrimental effects on Tetrahymena as a result of the increased generation of reactive oxygen species (ROS). In addition, the five Tetrahymena species showed different capacities in accumulating Hg 2+ and MeHg, with T. corlissi exhibiting the highest accumulations. The study also found significant growth-promoting effect on T. corlissi under low concentration exposure (0.003 and 0.01μg Hg/mL (15 and 50nM)), suggesting different effect and mechanism that should be more closely examined when assessing the bioaccumulation and toxicity of mercury in aquatic ecosystems. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. EURISOL Multi-MW Target: Investigation of the hydrodynamics of liquid metal (Hg) jet

    CERN Document Server

    Freibergs, J

    In order to develop a windowless target it is necessary to investigate the hydrodynamics of liquid metal (Hg) jet. On the basis of the schematic layout of a high-power target module presented in Ref. [2], and the parameters of the windowless target (speed of the mercury jet up to 30 m/s, diameter of jet 10-20 mm and length of jet about 1 m), a first estimation of the parameters of the main components of a Hg-loop has been obtained by the Institute of Physics, University of Latvia. A preliminary engineering design of a functional Hg-loop to be constructed soon is also proposed. A simplified water stand has been developed with the ability of testing different Hg-nozzle configurations. The tests carried out showed that the kinetic energy of the jet is so high that the coaxial water flow at contact point is transformed into small bubbles (spray). The characteristics of the jet were shown to depend on the pressure of the stand.

  4. Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits.

    Science.gov (United States)

    Bellini, Luca; Veladiano, Irene A; Schrank, Magdalena; Candaten, Matteo; Mollo, Antonio

    2018-02-27

    Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg. Bland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered. Although mean invasive

  5. Hg and Pt-metals in meteorite carbon-rich residues - Suggestions for possible host phase for Hg

    Science.gov (United States)

    Jovanovic, S.; Reed, G. W., Jr.

    1980-01-01

    Carbon-rich and oxide residual phases have been isolated from Allende and Murchison by acid demineralization for the determination of their Hg, Pt-metal, Cr, Sc, Co, and Fe contents. Experimental procedures used eliminated the possibility of exogenous and endogenous contaminant trace elements from coprecipitating with the residues. Large enrichments of Hg and Pt-metals were found in Allende but not in Murchison residues. Hg-release profiles from stepwise heating experiments suggest a sulfide as the host for Hg. Diffusion calculations for Hg based on these experiments indicate an activation energy of 7-8 kcal/mol, the same as that for Hg in troilite from an iron meteorite. This is further support for a sulfide host phase for Hg. Equilibration of Hg with this phase at approximately 900 K is indicated. Reasons for the presence of Pt-metals in noncosmic relative abundances are explored.

  6. Increased postdialysis systolic blood pressure is associated with extracellular overhydration in hemodialysis outpatients.

    Science.gov (United States)

    Nongnuch, Arkom; Campbell, Neil; Stern, Edward; El-Kateb, Sally; Fuentes, Laura; Davenport, Andrew

    2015-02-01

    Recently, intradialytic hypertension was reported to be associated with increased mortality for hemodialysis patients. To determine whether volume status plays a role in dialysis-associated hypertension, we prospectively audited 531 patients that had volume assessments measured by multiple-frequency bioelectrical impedance during their midweek dialysis session. Mean pre- and postdialysis weights were 73.2 vs 71.7 kg, and systolic blood pressures (SBPs) 140.5 vs. 130.3 mm Hg, respectively. Patients were divided into groups based on a fall in SBP of 20 mm Hg or more (32%), an increased SBP of 10 mm Hg or more (18%), and a stable group (50%). There were no differences in patient demographics, dialysis prescriptions, predialysis weight, total body (TBW), and extracellular (ECW) and intracellular water (ICW). However, the change in weight was significantly less in the increased blood pressure group (1.01 kg vs. stable 1.65, and 1.7 hypotensive). The ratio of ECW to TBW was significantly higher in the increased blood pressure group, particularly post dialysis (39.1 vs. stable 38.7% and fall in blood pressure group 38.7%). ECW overhydration was significantly greater in the increased blood pressure group post dialysis (0.7 (0.17 to 1.1) vs. stable 0.39 (-0.2 to 0.95) and fall in blood pressure group 0.38 (-0.19 to 0.86) liter). We found that patients who had increased blood pressure post dialysis had greater hydration status, particularly ECW. Thus, patients who increase their blood pressure post dialysis should have review of target weight, consideration of lowering the post-dialysis weight, and may benefit from increasing dialysis session time or frequency.

  7. Ocular onchocerciasis in the Yanomami communities from Brazilian Amazon: effects on intraocular pressure.

    Science.gov (United States)

    Herzog-Neto, Guilherme; Jaegger, Karen; Nascimento, Erika S do; Marchon-Silva, Verônica; Banic, Dalma M; Maia-Herzog, Marilza

    2014-01-01

    To determine the influence of onchocercal eye disease on the intraocular pressure of the Yanomami Tribe Aratha-ú of Roraima State, Brazil, considered endemic for onchocerciasis, a total of 86 patients were submitted to an ophthalmologic exam that included external examination, slit lamp examination, intraocular pressure measurement, and a fundus ophthalmoscope examination. A high prevalence of onchocerciasis-related eye lesions was encountered in 68.6% of the patients. Punctate keratitis and microfilariae in the anterior chamber were found in ∼28%. The mean of intraocular eye pressure found was 10.47 mm of Hg.

  8. Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia.

    Science.gov (United States)

    Poder, Thomas G; Pruneau, Denise; Dorval, Josée; Thibault, Louis; Fisette, Jean-François; Bédard, Suzanne K; Jacques, Annie; Beauregard, Patrice

    2016-01-01

    Blood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used. Pressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested. We found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C. To use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia.

  9. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the 'white-coat' effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-02-01

    Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a 'white-coat' effect. To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Retrospective study in a teaching hospital in Birmingham. Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the 'white-coat' effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm.

  10. Reduction of myocardial ischemia-reperfusion injury by mechanical tissue resuscitation using sub-atmospheric pressure.

    Science.gov (United States)

    Argenta, Louis C; Morykwas, Michael J; Mays, Jennifer J; Thompson, Edreca A; Hammon, John W; Jordan, James E

    2010-03-01

    Reperfusion-induced injury after myocardial infarction is associated with a well-defined sequence of early and late cardiomyocyte death. Most present attempts to ameliorate this sequence focus on a single facet of the complex process in an attempt to salvage cardiomyocytes. We examined, as proof of concept, the effects of mechanical tissue resuscitation (MTR) with controlled negative pressure on myocardial injury following acute myocardial infarction. Anesthetized swine were subjected to 75 minutes of left coronary artery occlusion and three hours of reperfusion. Animals were assigned to one of three groups: (A) untreated control; treatment of involved myocardium for 180 minutes of MTR with (B) -50 mmHg, or (C) -125 mmHg. All three groups were subjected to equivalent ischemic stress. Treatment of the ischemic area with MTR for 180 minutes significantly (p control: 9.3 +/- 1.8% (-50 mmHg) and 11.9 +/- 1.2% (-125 mmHg) versus 26.4 +/- 2.1% (control). Total area of cell death was reduced by 65% with -50 mmHg treatment and 55% in the -125 mmHg group. Treatment of ischemic myocardium with MTR, for a controlled period of time during reperfusion, successfully reduced the extent of myocardial death after acute myocardial infarction. These data provide evidence that MTR using subatmospheric pressure may be a simple, efficacious, nonpharmacological, mechanical strategy for decreasing cardiomyocyte death following myocardial infarction, which can be delivered in the operating room.

  11. Hg/HgO electrode and hydrogen evolution potentials in aqueous sodium hydroxide

    Energy Technology Data Exchange (ETDEWEB)

    Nickell, Ryan A.; Zhu, Wenhua H.; Payne, Robert U.; Cahela, Donald R.; Tatarchuk, Bruce J. [Center for Microfibrous Materials Manufacturing, Department of Chemical Engineering, 230 Ross Hall, Auburn University, Auburn, AL 36849 (United States)

    2006-10-27

    The Hg/HgO electrode is usually utilized as a reference electrode in alkaline solution such as for development of an alkaline hydrogen electrode. The reference electrode provides a suitable reference point but is available from few commercial vendors and suffers from inadequate documentation on potential in varying electrolytes. A new numerical method uses activity, activity coefficients, and a few correlated empirical equations to determine the potential values in both dilute and concentrated sodium hydroxide solutions at temperatures of 0-90{sup o}C and at concentrations of 0.100-12.8mol kg{sub H{sub 2}O}{sup -1}. The computed potentials of the Hg/HgO electrodes versus a normal hydrogen electrode (NHE) at 25{sup o}C and 1atm are 0.1634V for 0.100m, 0.1077V for 1.00m, and 0.0976V for 1.45m NaOH solutions. The Hg/HgO reduction potential further changes to -0.0751V versus NHE and hydrogen evolution potential changes to -0.9916V versus NHE in a solution of 30.0wt.% NaOH at 80{sup o}C. The calculated values are compared with the measured data at 25 and 75{sup o}C. The experimental data agree well with the numerical values computed from the theoretical and empirical equations. (author)

  12. Effects of neighborhood socioeconomic status on blood pressure in older adults

    Directory of Open Access Journals (Sweden)

    Katia Jakovljevic Pudla Wagner

    Full Text Available ABSTRACT OBJECTIVE To test if the neighborhood socioeconomic status is associated with systolic blood pressure and hypertension in older adults. METHODS A cross-sectional population-based study with a sample of 1,705 older adults from Florianópolis, SC, Southern Brazil. The contextual variable used was the average years of schooling of the head of the household in census tracts. Participants were considered hypertensive when the systolic blood pressure was ≥ 140 mmHg, diastolic ≥ 90 mmHg, or both. Additionally, the use of antihypertensive medication was also considered. Data were analyzed by using multilevel models of logistic and linear regression. RESULTS The average age of the sample was 70.7 years and the average of systolic and diastolic blood pressure was 133.5 mmHg (SD = 20.5 mmHg and 81.9 mmHg (SD = 12.5 mmHg, respectively. The systolic blood pressure was 4.46 mmHg (95%CI 1.00–7.92 higher and the chance of hypertension was 1.80 (95%CI 1.26–2.57 among those who lived in census tracts with lower level of schooling. When the use of antihypertensive medication was combined with blood pressure levels, none association was found between the outcome and the level of schooling of the census tract. CONCLUSIONS Analytical models more robust (such as multilevel analysis in Brazil are still little used, with a small number of articles published. Neighborhood socioeconomic status is associated with systolic blood pressure and the chance of hypertension, regardless of individual characteristics.

  13. Pressure sores following elective total hip arthroplasty: pitfalls of misinterpretation.

    Science.gov (United States)

    Keong, Nicole; Ricketts, David; Alakeson, Nuki; Rust, Philippa

    2004-01-01

    OBJECTIVE: To assess the reliability of reporting protocols regarding pressure sores. METHODS: Retrospective data were collected regarding pressure sore rates following total hip arthroplasty operations carried out during 2001 at two orthopaedic units in an NHS hospital (Princess Royal Hospital) and in a local private hospital. RESULTS: Preliminary results presented in audit and interim reports indicated an alarmingly high pressure sore rate across the two sites (17/172 [9.9%] NHS, 23/71 [32.4%] private hospital). On analysis, the data collection system was revealed to be flawed. Grade 1 areas (erythema with no ulceration) were included, leading to a dramatic discrepancy between reported and confirmed pressure sores. Re-analysis showed the confirmed pressure sore rates to be much lower (2.3% NHS, 1.0% private hospital). CONCLUSIONS: This audit suggests that both poor data collection and education lead to inaccurate audit. This may lead to subsequent inappropriate management and inappropriate NHS star ratings. PMID:15140301

  14. [Metformin and changes in blood pressure and heart rate in lean patients with polycystic ovary syndrome (PCOS)--preliminary study].

    Science.gov (United States)

    Tomczyk, Rita; Ociepka, Agnieszka; Kiałka, Marta; Milewicz, Tomasz; Migacz, Kamila; Kowalczuk, Aleksandra; Klocek, Marek

    2015-01-01

    The aim of our study was to assess the value of blood pressure and heart rate using the 24-hour blood pressure monitoring (ABPM) before and after treatment with metformin to patients with polycystic ovary syndrome (PCOS) and normal lean. 5 patients received metformin 1500 mg per day in three divided doses. ABPM was performed to each patient with PCOS twice: before and after 6 months of treatment with metformin. In patients with PCOS and normal lean after treatment with metformin we observed: statistically significant lower systolic blood pressure (120.2 ± 22.33 mmHg vs 113.22 ± 21.43 mm Hg, p = 0.0248); lower systolic blood pressure of daily measurements (127.1 ± 32.13 mmHg vs 116.1 ± 22.08 mmHg, p = 0.0062); reduction in average arterial pressure MAP in the measurement of the day (95.52 ± 22.76 mmHg vs 88.36 ± 16.41 mmHg, p = 0.048); oscillometric pressure reduction (96.27 ± 27.93 mmHg vs 87.82 ± 21.61, p = 0.0004 mmHg); oscillometric pressure reduction of daily measurements (102.1 ± 27.93 mmHg vs 91.85 ± 21.61 mmHg, p = 0.0032); oscillometric pressure reduction in the measure- ment of the night (88.81 ± 24.85 mmHg vs 82.22 ± 20.54 mmHg, p = 0.0089). In women after treatment with metformin has also been observed higher average heart rate (65.82 ± 13.48 / min vs. 70.71 ± 16.04 min; p PCOS and normal lean leads to lower blood pressure and increases the frequency of heart rate.

  15. Determination of equilibrium phase composition in the Hg-HgTe-CdTe system by ''dew point'' method

    International Nuclear Information System (INIS)

    Vanyukov, A.V.; Krotov, I.I.; Ermakov, A.I.

    1978-01-01

    Using the ''dew point'' method a study has been made of the equilibrium composition of the solid and liquid phases in the Hg-HgTe-CdTe system at 404, 435 and 454 deg C. It has been pointed out that crystallization of cadmium-rich solid solutions of Cdsub(x)Hgsub(1-x) Te takes place from a liquid phase with a much higher concentration of Hg. The activity of Hg in the liquid phase increases along the liquidus isotherm in the direction from section Hg-HgTe to section HgCdTe in accordance with the increase of its concentration. An increase in activity of Hg in the solid phase of Cdsub(x)Hgsub(1-x)Te has been noted with the reduction of its concentration

  16. Skin perfusion pressure on the legs measured as the external pressure required for skin reddening after blanching

    DEFF Research Database (Denmark)

    Holstein, P; Nielsen, P.E.; Lund, P

    1980-01-01

    -187) compared to 80.8 mmHg (range 18-158) (P > 0.1). A normal material was obtained from twenty-four subjects measured on the thigh, calf and ankle; the average gradients between the auscultatory brachial mean blood pressure and the BTEP were: thigh 10.7 mmHg (SD 12.7); calf 4.0 mmHg (SD 12.1); ankle 5.1 mm...

  17. Response of the arterial blood pressure of quadriplegic patients to treadmill gait training

    Directory of Open Access Journals (Sweden)

    D.C.L. Carvalho

    2005-09-01

    Full Text Available Blood pressure pattern was analyzed in 12 complete quadriplegics with chronic lesions after three months of treadmill gait training. Before training, blood pressure values were obtained at rest, during treadmill walking and during the recovery phase. Gait training was performed for 20 min twice a week for three months. Treadmill gait was achieved using neuromuscular electrical stimulation, assisted by partial body weight relief (30-50%. After training, blood pressure was evaluated at rest, during gait and during recovery phase. Before and after training, mean systolic blood pressures and heart rates increased significantly during gait compared to rest (94.16 ± 5.15 to 105 ± 5.22 mmHg and 74.27 ± 10.09 to 106.23 ± 17.31 bpm, respectively, and blood pressure decreased significantly in the recovery phase (86.66 ± 9.84 and 57.5 ± 8.66 mmHg, respectively. After three months of training, systolic blood pressure became higher at rest (94.16 ± 5.15 mmHg before training and 100 ± 8.52 mmHg after training; P < 0.05 and during gait exercise (105 ± 5.22 mmHg before and 110 ± 7.38 mmHg after training; P < 0.05 when compared to the initial values, with no changes in heart rate. No changes occurred in blood pressure during the recovery phase, with the lower values being maintained. A drop in systolic pressure from 105 ± 5.22 to 86.66 ± 9.84 mmHg before training and from 110 ± 7.38 to 90 ± 7.38 mmHg after training was noticed immediately after exercise, thus resulting in hypotensive symptoms when chronic quadriplegics reach the sitting position from the upright position.

  18. Circadian rhythms in blood pressure in free-ranging three-toed sloths (Bradypus variegatus

    Directory of Open Access Journals (Sweden)

    Duarte D.P.F.

    2003-01-01

    Full Text Available Blood pressure (BP profiles were monitored in nine free-ranging sloths (Bradypus variegatus by coupling one common carotid artery to a BP telemetry transmitter. Animals moved freely in an isolated and temperature-controlled room (24ºC with 12/12-h artificial light-dark cycles and behaviors were observed during resting, eating and moving. Systolic (SBP and diastolic (DBP blood pressures were sampled for 1 min every 15 min for 24 h. BP rhythm over 24 h was analyzed by the cosinor method and the mesor, amplitude, acrophase and percent rhythm were calculated. A total of 764 measurements were made in the light cycle and 721 in the dark cycle. Twenty-four-hour values (mean ± SD were obtained for SBP (121 ± 22 mmHg, DBP (86 ± 17 mmHg, mean BP (MBP, 98 ± 18 mmHg and heart rate (73 ± 16 bpm. The SBP, DBP and MBP were significantly higher (unpaired Student t-test during the light period (125 ± 21, 88 ± 15 and 100 ± 17 mmHg, respectively than during the dark period (120 ± 21, 85 ± 17 and 97 ± 17 mmHg, respectively and the acrophase occurred between 16:00 and 17:45 h. This circadian variation is similar to that observed in cats, dogs and marmosets. The BP decreased during "behavioral sleep" (MBP down from 110 ± 19 to 90 ± 19 mmHg at 21:00 to 8:00 h. Both feeding and moving induced an increase in MBP (96 ± 17 to 119 ± 17 mmHg at 17:00 h and 97 ± 19 to 105 ± 12 mmHg at 15:00 h, respectively. The results show that conscious sloths present biphasic circadian fluctuations in BP levels, which are higher during the light period and are mainly synchronized with feeding.

  19. Blood Pressure Control among Treated Hypertensives in a Tertiary ...

    African Journals Online (AJOL)

    Background: Goal blood pressure (BP) was defined by the JNC VI and the World Health Organization- International Society of Hypertension (WHO/ISH) as <140 mm Hg systolic and <90 mm Hg diastolic for the general and <130 mm Hg systolic and <85 mm Hg diastolic for special high-risk populations. It is well established ...

  20. HgI2 nanostructures obtained hydrothermally for application in ionizing radiation detection

    International Nuclear Information System (INIS)

    Pérez Barthaburu, María; Bentos Pereira, Heinkel; Fornaro, Laura; Galain, Isabel; Aguiar, Ivana

    2016-01-01

    The compound semiconductor HgI 2 has been widely studied and employed as a material for ionizing radiation detection. Monocrystal growth is an intricate method for obtaining materials for this application. With the aim of finding a simpler and more effective way to develop ionizing radiation detectors, we employed HgI 2 nanostructures subjected to a hydrothermal treatment and then pressed for this purpose. In the synthesis procedure, aqueous solutions of Hg(NO 3 ) 2 and NaI were mixed until their reaction completed and the suspension obtained was then placed in a homemade autoclave and heated at 120 °C for 2, 10 or 24 h. We confirmed the HgI 2 tetragonal phase by powder XRD in all cases, independently of the synthesis conditions employed. Nanoparticles were characterized by their size and morphology by TEM. We used the HgI 2 nanostructures to obtain a pellet by applying 0.7 GPa of pressure at room temperature. The pellet was then used to construct the detector, and we studied the electrical properties of the detector and its response to 241 Am sources of different exposure rates. The resistivity and signal-to-noise ratio obtained are of the order of those reported for HgI 2 detectors assembled with monocrystals. The results obtained in this work encourage us to work further on this topic, improving the method, scaling the detector’s size and studying its spectrometric grade. (paper)

  1. Validation of the Andon KD-5851 upper arm blood pressure monitor, for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Wu, Lili; Jiao, Yinghui; Wang, Chengdong; Chen, Lei; Di, Dalin; Zhang, Haiyan

    2015-08-01

    This study aimed to validate the Andon KD-5851 upper arm blood pressure (BP) monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. A total of 33 eligible participants were included in the study. Sequential measurements of BPs were performed using a mercury sphygmomanometer and the device, and the data analysis was carried out following precisely the ESH-IP revision 2010. The device had 82, 98, and 99 measurements within 5, 10, and 15 mmHg for systolic blood pressure and 85, 95, and 99 measurements for diastolic blood pressure, respectively. The average device-observer difference was -0.53±4.00 mmHg for systolic blood pressure and -1.15±4.06 mmHg for diastolic blood pressure. The device passed all the criteria according to the ESH-IP revision 2010. According to the validation results on the basis of the ESH-IP revision 2010, the Andon KD-5851 upper arm BP monitor can be recommended for self/home measurement in adults. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.

  2. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the ‘white-coat’ effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-01-01

    Background Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a ‘white-coat’ effect. Aim To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Design and setting Retrospective study in a teaching hospital in Birmingham. Method Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Result Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Conclusion Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the ‘white-coat’ effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm. PMID:23561681

  3. The mercury chromates Hg6Cr2O9 and Hg6Cr2O10-Preparation and crystal structures, and thermal behaviour of Hg6Cr2O9

    International Nuclear Information System (INIS)

    Weil, Matthias; Stoeger, Berthold

    2006-01-01

    The basic mercury(I) chromate(VI), Hg 6 Cr 2 O 9 (=2Hg 2 CrO 4 .Hg 2 O), has been obtained under hydrothermal conditions (200deg. C, 5 days) in the form of orange needles as a by-product from reacting elemental mercury and K 2 Cr 2 O 7 . Hydrothermal treatment of microcrystalline Hg 6 Cr 2 O 9 in demineralised water at 200deg. C for 3 days led to crystal growth of red crystals of the basic mercury(I, II) chromate(VI), Hg 6 Cr 2 O 10 (=2Hg 2 CrO 4 .2HgO). The crystal structures were solved and refined from single crystal X-ray data sets. Hg 6 Cr 2 O 9 : space group P2 1 2 1 2 1 , Z=4, a=7.3573(12), b=8.0336(13), c=20.281(3)A, 3492 structure factors, 109 parameters, R[F 2 >2σ(F 2 )]=0.0371, wR(F 2 all)=0.0517; Hg 6 Cr 2 O 10 : space group Pca2 1 , Z=4, a=11.4745(15), b=9.4359(12), c=10.3517(14)A, 3249 structure factors, 114 parameters, R[F 2 >2σ(F 2 )]=0.0398, wR(F 2 all)=0.0625. Both crystal structures are made up of an intricate mercury-oxygen network, subdivided into single building blocks [O-Hg-Hg-O] for the mercurous compound, and [O-Hg-Hg-O] and [O-Hg-O] for the mixed-valent compound. Hg 6 Cr 2 O 9 contains three different Hg 2 2+ dumbbells, whereas Hg 6 Cr 2 O 10 contains two different Hg 2 2+ dumbbells and two Hg 2+ cations. The Hg I -Hg I distances are characteristic and range between 2.5031(15) and 2.5286(9)A. All Hg 2 2+ groups exhibit an unsymmetrical oxygen environment. The oxygen coordination of the Hg 2+ cations is nearly linear with two tightly bonded O atoms at distances around 2.07A. For both structures, the chromate(VI) anions reside in the vacancies of the Hg-O network and deviate only slightly from the ideal tetrahedral geometry with average Cr-O distances of ca. 1.66A. Upon heating at temperatures above 385deg. C, Hg 6 Cr 2 O 9 decomposes in a four-step mechanism with Cr 2 O 3 as the end-product at temperatures above 620 deg. C

  4. Comparison of regional pancreatic tissue fluid pressure and endoscopic retrograde pancreatographic morphology in chronic pancreatitis

    DEFF Research Database (Denmark)

    Ebbehøj, N; Borly, L; Madsen, P

    1990-01-01

    . The predrainage pressures were higher in the tail of the pancreas (29 mm Hg; range, 16-37 mm Hg) than in the head (18 mm Hg; range, 2-30 mm Hg; p = 0.02). The regional pressure differences were significantly greater in four patients who had previously undergone pancreatic surgery than in the 12 patients without...

  5. LB03.04: SPHYGMOMANOMETER CUFF CONSTRUCTION AND MATERIALS AFFECT TRANSMISSION OF PRESSURE FROM CUFF TO ARTERIAL WALL. FINITE ELEMENT ANALYSIS OF HUMAN PRESSURE MEASUREMENTS AND DICOM DATA.

    Science.gov (United States)

    Lewis, P; Naqvi, S; Mandal, P; Potluri, P

    2015-06-01

    Sphygmomanometer cuff pressure during deflation is assumed to equal systolic arterial pressure at the point of resumption of flow. Previous studies demonstrated that pressure decreases with increasing depth of soft tissues whilst visco-elastic characteristics of the arm tissue cause spatial and temporal variation in pressure magnitude. These generally used non-anatomical axisymmetrical arm simulations without incorporating arterial pressure variation. We used data from a volunteer's Magnetic Resonance (MR) arm scan and investigated the effect of variations in cuff materials and construction on the simulated transmission of pressure from under the cuff to the arterial wall under sinusoidal flow conditions. Pressure was measured under 8 different cuffs using Oxford Pressure Monitor Sensors placed at 90 degrees around the mid upper arm of a healthy male. Each cuff was inflated 3 times to 155 mmHg and then deflated to zero with 90 seconds between inflations. Young's modulus, flexural rigidity and thickness of each cuff was measured.Using DICOM data from the MR scan of the arm, a 3D model was derived using ScanIP and imported into Abaqus for Finite Element Analysis (FEA). Published mechanical properties of arm tissues and geometric non-linearity were assumed. The measured sub-cuff pressures were applied to the simulated arm and pressure was calculated around the brachial arterial wall. which was loaded with a sinusoidal pressure of 125/85 mmHg. FEA estimates of pressure around the brachial artery cuffs varied by up to 27 mmHg SBP and 17 mmHg DBP with different cuffs. Pressures within the cuffs varied up to 27 mmHg. Pressure transmission from the cuff to the arterial surface achieved a 95% transmission ratio with one rubber-bladdered cuff but varied between 76 and 88% for the others. Non-uniform pressure distribution around the arterial wall was strongly related to cuff fabric elastic modulus. Identical size cuffs with a separate rubber bladder produced peri

  6. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  7. Crystal structure of the Hg4SiS6 and Hg4SiSe6 compounds

    International Nuclear Information System (INIS)

    Gulay, L.D.; Olekseyuk, I.D.; Parasyuk, O.V.

    2002-01-01

    The crystal structures of Hg 4 SiS 6 and Hg 4 SiSe 6 compounds were investigated using X-ray powder diffraction. These compounds crystallize in the monoclinic Cc space group with the lattice parameters a=1.23020(5), b=0.71031(4), c=1.22791(4) nm, β=109.721(3) deg. for Hg 4 SiS 6 and a=1.28110(4), b=0.74034(4), c=1.27471(1) nm, β=109.605(3) deg. for Hg 4 SiSe 6 . Atomic parameters were refined in the isotropic approximation (R I =0.0571 and R I =0.0555 for the Hg 4 SiS 6 and Hg 4 SiSe 6 , respectively)

  8. Phenylephrine-induced elevations in arterial blood pressure are attenuated in heat-stressed humans

    Science.gov (United States)

    Cui, Jian; Wilson, Thad E.; Crandall, Craig G.

    2002-01-01

    To test the hypothesis that phenylephrine-induced elevations in blood pressure are attenuated in heat-stressed humans, blood pressure was elevated via steady-state infusion of three doses of phenylephrine HCl in 10 healthy subjects in both normothermic and heat stress conditions. Whole body heating significantly increased sublingual temperature by 0.5 degrees C, muscle sympathetic nerve activity (MSNA), heart rate, and cardiac output and decreased total peripheral vascular resistance (TPR; all P blood pressure (MAP; P > 0.05). At the highest dose of phenylephrine, the increase in MAP and TPR from predrug baselines was significantly attenuated during the heat stress [DeltaMAP 8.4 +/- 1.2 mmHg; DeltaTPR 0.96 +/- 0.85 peripheral resistance units (PRU)] compared with normothermia (DeltaMAP 15.4 +/- 1.4 mmHg, DeltaTPR 7.13 +/- 1.18 PRU; all P blood pressure, as well as the slope of the relationship between heart rate and systolic blood pressure, respectively, was similar between thermal conditions (each P > 0.05). These data suggest that phenylephrine-induced elevations in MAP are attenuated in heat-stressed humans without affecting baroreflex control of MSNA or heart rate.

  9. Mercury (Hg) speciation in coral reef systems of remote Oceania: Implications for the artisanal fisheries of Tutuila, Samoa Islands.

    Science.gov (United States)

    Morrison, R John; Peshut, Peter J; West, Ronald J; Lasorsa, Brenda K

    2015-07-15

    We investigated Hg in muscle tissue of fish species from three trophic levels on fringing reefs of Tutuila (14°S, 171°W), plus water, sediment and turf alga. Accumulation of total Hg in the herbivore Acanthurus lineatus (Acanthuridae, lined surgeonfish, (n=40)) was negligible at 1.05 (±0.04) ng g(-1) wet-weight, (∼65% occurring as methyl Hg). The mid-level carnivore Parupeneus spp. (Mullidae, goatfishes (n=10)) had total Hg 29.8 (±4.5) ng g(-1) wet-weight (∼99% as methyl Hg). Neither A. lineatus or Parupeneus spp. showed a propensity to accumulate Hg based on body size. Both groups were assigned a status of "un-restricted" for monthly consumption limits for non-carcinogenic health endpoints for methyl Hg. The top-level carnivore Sphyraena qenie (Sphyraenidae, blackfin barracuda, n=3) had muscle tissue residues of 105, 650 and 741 ng g(-1) wet-weight (100% methyl Hg, with increasing concentration with body mass, suggesting that S. qenie >15 kg would have a recommendation of "no consumption". Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  11. COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

    Directory of Open Access Journals (Sweden)

    Muhaji

    2017-12-01

    Full Text Available Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU, which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05. The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.

  12. Contralateral limb during total contact casting. A dynamic pressure and thermometric analysis.

    Science.gov (United States)

    Armstrong, D G; Liswood, P J; Todd, W F

    1995-12-01

    The authors draw attention to the importance of evaluation of the contralateral limb when treating unilateral sequelae secondary to distal symmetrical polyneuropathy. Plantar pressure measurements of the contralateral limb during total contact casting are reviewed. The results of thermometric evaluation before and after initiation of repetitive stress were reviewed. The results suggest that the patient walking in a total contact cast may experience a reduced focal pressure on the contralateral limb when compared with uncasted walking and three-point walking with crutches. Dermal thermometry may be a highly sensitive tool in evaluating even mild increases in repetitive stress. To explain this decrease in contralateral stress, the authors examine the features inherent to the total contact cast and propose the concept of proprioceptive stability.

  13. Characteristic of intraocular pressure distribution in population of 1115 Tibetan aged 40 years old or more

    Directory of Open Access Journals (Sweden)

    Gui-Qin Wang

    2014-07-01

    Full Text Available AIM: To analyze of characteristic of intraocular pressure(IOPdistribution in population of 1115 Tibetan aged 40 years old or more and its correlative factors such as ages, gender and anterior chamber depth in Tibetan plateau area. METHODS: A total of 1115 Tibetan permanent residents aged 40 years or older from the towns and villages of Qushui County were divided into four age groups: ≥40~RESULTS: The mean IOP of 1115(2145 eyesTibetan permanent residents aged 40 years or older was 12.9±2.7mmHg, 13.2±2.8mmHg in men and 12.7±2.5mmHg in women. The results showed that the participants with anterior chamber depth of 1/2 corneal thickness had 68.8% in 1115(2128 eyesTibetan permanent residents and anterior chamber depth decreases significantly with age(PPCONCLUSION: The mean IOP of plateau subjects was significantly lower from that of plain subjects by approximately 3 mmHg. There are lower pressure, deeper anterior chamber depth in this population of 1115 Tibetan permanent residents. The more attention should be paid to screening for glaucoma in high plateau.

  14. Hair mercury (Hg) levels, fish consumption and semen parameters among men attending a fertility center.

    Science.gov (United States)

    Mínguez-Alarcón, Lidia; Afeiche, Myriam C; Williams, Paige L; Arvizu, Mariel; Tanrikut, Cigdem; Amarasiriwardena, Chitra J; Ford, Jennifer B; Hauser, Russ; Chavarro, Jorge E

    2018-03-01

    General population exposure to methylmercury (MeHg), the most common organic mercury compound found in the environment, occurs primarily through the consumption of contaminated fish and shellfish. Due to limited studies and lack of consideration of effect modification by fish consumption, it remains uncertain if exposure to mercury affects semen parameters. Thus, we investigated whether hair Hg levels, a biomarker of mercury exposure, were associated with semen parameters among men attending an academic fertility center, and whether this relationship was modified by intake of fish. This analysis included 129 men contributing 243 semen samples who were enrolled in the Environment and Reproductive Health (EARTH) Study between 2005 and 2013, and had data of hair Hg, intake of fish and semen parameters available. Hair Hg levels were assessed using a direct mercury analyzer. Intake of fish was collected using a validated food frequency questionnaire. Semen parameters were analyzed following WHO 2010 evaluation criteria. Generalized linear mixed models with random intercepts accounting for within-man correlations across semen samples were used to evaluate the association of hair Hg levels and semen parameters adjusting for age, BMI, smoking status, abstinence time and alcohol intake. Effect modification by total fish intake (≤1.68 vs. >1.68 servings/week) was tested. The median hair Hg levels of the men was 0.72ppm and ranged from 0.03 to 8.01ppm; almost 30% of the men had hair Hg levels >1ppm. Hair Hg levels were positively related with sperm concentration, total sperm count, and progressive motility, after adjusting for potential confounders and became attenuated after further adjustment for fish intake. Specifically, men in the highest quartile of hair mercury levels had 50%, 46% and 31% higher sperm concentration, total sperm count and progressive motility, respectively, compared to men in the lowest quartile. These associations were stronger among men whose fish

  15. Child Abuse, Resting Blood Pressure, and Blood Pressure Reactivity to Psychosocial Stress.

    Science.gov (United States)

    Gooding, Holly C; Milliren, Carly E; Austin, S Bryn; Sheridan, Margaret A; McLaughlin, Katie A

    2016-01-01

    Childhood trauma is associated with hypertension in adults. It is unknown whether childhood trauma predicts elevated blood pressure earlier in development. We investigated whether the trauma of child abuse was associated with blood pressure in adolescents. The sample included 145 adolescents aged 13-17 years, 40% with exposure to child abuse. The mean age of participants was 14.93 years (SD = 1.33); 58% were female. The majority self-identified as non-Hispanic White (43%), with the remainder identifying as non-Hispanic Black (17%), Hispanic (17%), or other/mixed race (23%). We used established age/sex/height-specific cutoffs to determine the prevalence of prehypertension and hypertension in the sample. We used two-sample t tests to examine associations of abuse with resting systolic blood pressure (SBP) and diastolic blood pressure (DBP) and blood pressure reactivity to the Trier Social Stress Test and a frustration task. We used linear regression to adjust for potential confounders including sociodemographic variables, body mass index, smoking, and psychopathology. Mean resting SBP and DBP were 114.07 mmHg and 61.35 mmHg in those with a history of abuse and 111.39 mmHg and 56.89 mmHg in those without a history of abuse. This difference was significant for DBP only. Twelve percent of participants met criteria for prehypertension or hypertension based on resting blood pressure values; this did not differ between those with and without an abuse history. Child abuse was associated with lower DBP and SBP reactivity to laboratory stress tasks and reduced DBP reactivity to frustration. These associations were robust to adjustment for potential confounders. Child abuse is associated with higher resting DBP and blunted DBP and SBP reactivity to laboratory stress in adolescence. These findings suggest a potential pathway by which child abuse leads to hypertension. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All

  16. Correlation Between Doppler Echocardiography and Right Heart Catheterization Derived Pulmonary Artery Pressures: Impact of Right Atrial Pressures

    International Nuclear Information System (INIS)

    Ahmed, I.; Nuri, M. M. H.; Zakariyya, A. N.; Ahmad, S. M.; Ahmed, M.

    2016-01-01

    Objective: To evaluate the correlation between Doppler echocardiography (DE) and right heart catheterization (RHC) derived pulmonary artery pressures and to assess the impact of right atrial (RA) pressures on this correlation. Study Design: Cross-sectional analytical study. Place and Duration of Study: Cardiology Department, Tahir Heart Institute, Chenab Nagar, from June 2013 to December 2014. Methodology: All patients undergoing RHC were included. Relevant data were collected from hospital database. Continuous variables were expressed as the mean and SD or as the median and interquartile range where the distributions were skewed. Pearson correlation coefficient and Bland-Altman method were used to correlate DE derived right ventricular systolic pressure (RVSP) and RHC derived systolic pulmonary artery pressures (sPAP). Adjusted RVSP was calculated by replacing default value of RA pressure (10 mmHg) with RHC derived mean RA pressure. Receiver operating characteristic curve (ROC) was used to identify the best cut-off value of RVSP in predicting pulmonary hypertension. Results: Fifty-one patients completed the study protocol. Mean age of study population was 45.22 ± 15.25 years with male to female ratio of 1.47:1. Median error was 13 mmHg (7 to 20). Pearson correlation coefficient (r) between RVSP and sPAP was 0.72. Bland-Altman method of correlation showed bias of +4.43 mmHg with 95% limits of agreement ranging from -34.61 to +43.47. Using ROC curve, the best cut-off value of RVSP was greater than 52 mmHg with accuracy of 75% (sensitivity: 81%, specificity: 69%) in predicting pulmonary hypertension. Adjusted RVSP showed only little improvement in correlation (r = 0.75), adjusted error (13.65 ± 13.05) and diagnostic accuracy (79%). Conclusion: Doppler echocardiography can frequently overestimate pulmonary artery pressures. Though correctly estimated RA pressure may improve this correlation, yet its contribution is only minimal. (author)

  17. Mercury nonstoichiometry of the Hg1-xBa2CuO4+δ superconductor and the P(Hg)-P(O2)-T phase diagram of the Hg-Ba-Cu-O system

    International Nuclear Information System (INIS)

    Alyoshin, V.A.; Mikhailova, D.A.; Rudnyi, E.B.; Antipov, E.V.

    2002-01-01

    The P(Hg)-P(O 2 )-T phase diagram of the Hg-Ba-Cu-O system for the Ba:Cu=2:1 ratio was experimentally studied and followed by means of the thermodynamic modeling. It was shown that the Hg 1-x Ba 2 CuO 4+δ (Hg-1201) superconductor possesses a significant range of Hg-nonstoichiometry and exists in a certain P(Hg), P(O 2 ) and T range. Mercury nonstoichiometry of Hg-1201 was investigated in the 923≤T≤1095 K; 2.0≤P(Hg)≤8.4 atm; 0.09≤P(O 2 )≤0.86 atm ranges. It was found that the mercury content varies in the range of 0.80-0.94 under these conditions. The Gibbs energy of the Hg-1201 phase was estimated as a function of temperature and mercury concentration. The obtained results allow optimizing the synthesis conditions of Hg-1201 with a given Hg-content including preparation of the Hg-stoichiometric phase

  18. Is aerobic workload positively related to ambulatory blood pressure?

    DEFF Research Database (Denmark)

    Korshøj, Mette; Clays, Els; Lidegaard, Mark

    2016-01-01

    workload and ambulatory blood pressure (ABP) are lacking. The aim was to explore the relationship between objectively measured relative aerobic workload and ABP. METHODS: A total of 116 cleaners aged 18-65 years were included after informed consent was obtained. A portable device (Spacelabs 90217......) was mounted for 24-h measurements of ABP, and an Actiheart was mounted for 24-h heart rate measurements to calculate relative aerobic workload as percentage of relative heart rate reserve. A repeated-measure multi-adjusted mixed model was applied for analysis. RESULTS: A fully adjusted mixed model...... of measurements throughout the day showed significant positive relations (p ABP and 0.30 ± 0.04 mmHg (95 % CI 0.22-0.38 mmHg) in diastolic ABP. Correlations between...

  19. Antioxidative response of Lepidium sativum L. during assisted phytoremediation of Hg contaminated soil.

    Science.gov (United States)

    Smolinska, Beata; Szczodrowska, Agnieszka

    2017-09-25

    In this study, Lepidium sativum L. was used in repeated phytoextraction processes to remove Hg from contaminated soil, assisted by combined use of compost and iodide (KI). L. sativum L. is sensitive to changes in environmental conditions and has been used in environmental tests. Its short vegetation period and ability to accumulate heavy metals make it suitable for use in repeated phytoextraction. The antioxidant enzymatic system of the plant (catalase (CAT), ascorbate peroxidase (APX), superoxide dismutase (SOD) and glutathione S-transferase (GST)) was analysed, to understand the effects of increasing Hg accumulation and translocation. Phytoextraction was repeated six times to decrease Hg contamination in soil, and the efficiency of each step was assessed. The results indicate that L. sativum L. is able to take up and accumulate Hg from contaminated soil. A corresponding increase in enzymatic antioxidants shows that the plant defence system is activated in response to Hg stress. Using compost and KI increases total Hg accumulation and translocation to the above-ground parts of L. sativum L. Repeating the process decreases Hg contamination in pot experiments in all variants of the process. The combined use of compost and KI during repeated phytoextraction increases the efficiency of Hg removal from contaminated soil. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Effects of salt substitute on home blood pressure differs according to age and degree of blood pressure in hypertensive patients and their families.

    Science.gov (United States)

    Hu, Jihong; Zhao, Liancheng; Thompson, Brian; Zhang, Yawei; Wu, Yangfeng

    2018-02-05

    It is known that home blood pressure (HBP) is a more reliable assessment of hypertension treatments than clinical blood pressure (BP). Despite this, HBP response to a salt substitute has only been evaluated by one study which, did not look at the salt substitute's effect on family members and did not analyze by age, gender, or BP degree. The aim of this current study was to assess the effects of a low-sodium and high-potassium salt substitute on HBP among hypertensive patients and their family members. A total of 220 households (including 220 hypertensive patients and 380 their families) were randomly assigned to the regular salt or salt substitute groups. HBP was measured at the beginning, 3rd, 6th, and 12th months. Among the patients (n = 220), only home systolic blood pressure (HSBP) was significantly reduced, by an adjusted baseline BP of 4.2 mm Hg (95% CI: 1.3-7.0 mm Hg), in the salt substitute group compared with those in the regular salt group at each visit (all P blood pressure (HDBP) at any visit. Among the family members, HSBP and HDBP were not significantly different between the groups. Furthermore, Individuals ≥60 years old, hypertensive patients with stage-2 hypertension, family members with hypertension, and women experienced greater HSBP reduction. Older subjects, those with higher blood pressure, and women experienced greater home blood pressure reduction from the salt substitute compared to regular salt.

  1. Effects of renal sympathetic denervation on 24-hour blood pressure variability

    Directory of Open Access Journals (Sweden)

    Christine Stefanie Zuern

    2012-05-01

    Full Text Available Background: In patients with arterial hypertension, increased blood pressure (BP variability contributes to end organ damage independently from mean levels of arterial BP. Increased BP variability has been linked to alterations in autonomic function including sympathetic overdrive. We hypothesized that catheter-based renal sympathetic denervation (RDN confers beneficial effects on BPV. Methods and Results: Eleven consecutive patients with therapy-refractory arterial hypertension (age 68.9±7.0 years; baseline systolic BP 189±23mmHg despite medication with 5.6±2.1 antihypertensive drugs underwent bilateral RDN. Twenty-four hour ambulatory blood pressure monitoring (ABPM was performed before RDN and six months thereafter. BPV was primarily assessed by means of standard deviation of 24-hour systolic arterial blood pressures (SDsys. Secondary measures of BPV were maximum systolic blood pressure (MAXsys and maximum difference between two consecutive readings of systolic BP (deltamaxsys over 24 hours. Six months after RDN, SDsys, MAXsys and deltamaxsys were significantly reduced from 16.9±4.6mmHg to 13.5±2.5mmHg (p=0.003, from 190±22mmHg to 172±20mmHg (p<0.001 and from 40±15mmHg to 28±7mmHg (p=0.006, respectively, without changes in concomitant antihypertensive therapy. Reductions of SDsys, MAXsys and deltamaxsys were observed in 10/11 (90.9%, 11/11 (100% and 9/11 (81.8% patients, respectively. Although we noted a significant reduction of systolic office blood pressure by 30.4±27.7mmHg (p=0.007, there was only a trend in reduction of average systolic BP assessed from ABPM (149±19mmHg to 142±18mmHg; p=0.086.Conclusions: In patients with therapy-refractory arterial hypertension, RDN leads to significant reductions of BP variability. Effects of RDN on BPV over 24 hours were more pronounced than on average levels of BP.

  2. Just passing through --- high Hg deposition to Puerto Rico forest moves quickly off the landscape

    Science.gov (United States)

    Shanley, J. B.; Willenbring, J. K.; Kaste, J. M.; Occhi, M.; McDowell, W. H.

    2012-12-01

    Atmospheric mercury (Hg) in wet deposition at the Luquillo Experimental Forest in northeastern Puerto Rico, averages 28 μg m-2 yr-1, higher than any site in the USA Mercury Deposition Network. Despite the high deposition, Hg content of soils, vegetation, and biota are below global averages. The low Hg content of watershed surfaces, coupled with exceptionally high stream total Hg flux, suggest that most of the Hg passes through the watershed with minimal retention. We assessed Hg dynamics in two adjacent watersheds, Rio Icacos underlain by quartz diorite, and Rio Mameyes underlain by volcaniclastic rocks. At both sites, high-flow Hg concentrations approached 100 ng L-1, dominated by particulate Hg. In order to assess the apparent pass-through nature of Hg in this tropical forest, we measured 7Be and 10Be isotopes from natural, cosmogenic fallout adsorbed on stream suspended particles to constrain the Hg age /residence time and source (atmospheric vs. geogenic or legacy Hg from 19th century gold mining). Ubiquitous 7Be (half-life 53 days) and relatively high 7Be/10Be ratios on suspended particles suggest that stream Hg was dominated by erosion from exposed surfaces, supporting a short residence time. The low watershed retention of the high Hg throughput limits adverse biological effects in this tropical ecosystem.

  3. Note: Simple means for selective removal of the 365 nm line from the Hg spectrum using Dy

    DEFF Research Database (Denmark)

    Vesborg, Peter Christian Kjærgaard; Chorkendorff, Ib; Brock-Nannestad, T.

    2011-01-01

    is cheap, robust, and stable towards degradation or bleaching - even under intense irradiation. The absorption spectrum for the Dy-filter is presented along with emission spectra from both low-pressure and high-pressure Hg-lamps to illustrate the utility of the technique under best-case and worst...

  4. Noise exposure at school and blood pressure in adolescents

    Directory of Open Access Journals (Sweden)

    Fadhilah Ihsani

    2017-01-01

    Full Text Available Background The increasing prevalence of primary hypertension has motivated researchers to identify influencing factors, one of which is noise. There have been few studies on a relationships between noise exposure and blood pressure in children, and none have dealt exclusively with adolescents. Objective To assess for an association between noise exposure at school and blood pressure in adolescents.   Methods To identify noisy and quiet schools, the mean noise levels of 192 senior high schools in Medan were measured using sound level meters. One noisy school and one quiet school were randomly selected for inclusion (mean noise levels of  68.2 and  53.8 dB, respectively. Students from both schools underwent blood pressure measurements by mercury sphygmomanometer. Their Body weights and heights were obtained for body mass index calculations. Subjects filled questionnaires and their parents were interviewed regarding history of illnesses. Results Of the 271 adolescents recruited, 136 (50.2% were from the noisy school. Adolescents from the noisy school had higher mean systolic and diastolic blood pressures [121.6 (SD 13.87 mmHg and 71.1 (SD 8.15 mmHg, respectively], than those from the quiet school [111.8 (SD 12.61 mmHg and 63.8 (SD 8.05 mmHg, respectively]. After adjusting for other factors, noise had a significant, moderate, positive association with systolic and diastolic blood pressures [β = 0.452; B = 6.21 (95% CI 3.86-8.55 mmHg; and β = 0.473; B = 4.18 (95% CI 2.41 to 5.94 mmHg, respectively]. Conclusion Adolescents from a noisy school have a greater risk of higher systolic and diastolic blood pressures than those from a quiet school.

  5. Home Blood Pressure Monitoring as an Alternative to Confirm Diagnoses of Hypertension in Adolescents with Elevated Office Blood Pressure from a Brazilian State Capital

    Science.gov (United States)

    Póvoa, Thaís Inacio Rolim; Jardim, Thiago Veiga; Carneiro, Carolina de Souza; Ferreira, Vanessa Roriz; Mendonça, Karla Lorena; de Morais, Polyana Resende Silva; Nascente, Flávia Miquetichuc Nogueira; de Souza, Weimar Kunz Sebba Barroso; Sousa, Ana Luiza Lima; Jardim, Paulo César Brandão Veiga

    2017-01-01

    Background Regional differences of using home blood pressure monitoring (HBPM) as an alternative to ambulatory blood pressure monitoring (ABPM) in hypertensive adolescents are unknown. Objectives Define if HBPM is an option to confirm diagnoses of hypertension in adolescents from a Brazilian capital with elevated office blood pressure (BP). Methods Adolescents (12-18years) from public and private schools with BP > 90th percentile were studied to compare and evaluate the agreement among office BP measurements, HBPM and ambulatory BP monitoring. Office BP measurements, HBPM and ABPM were performed according to guidelines recommendations. Semi-automatic devices were used for BP measurements. Values of p ABPM values (120.3 ± 12.6 mmHg x 121.5 ± 9.8 mmHg - p = 0.111 and 69.4 ± 7.7 mmHg x 70.2 ± 6.6 mmHg - p = 0.139) and lower than the office measurement values (127.3 ± 13.8 mmHg over 74.4 ± 9.5 mmHg - p ABPM. Conclusions HBPM is an option to confirm diagnoses of hypertension in adolescents from a Brazilian state capital with elevated office BP and can be used as an alternative to ABPM. PMID:28793045

  6. Investigation of Hg uptake and transport between paddy soil and rice seeds combining Hg isotopic composition and speciation

    OpenAIRE

    C. Feng; Z. Pedrero; P. Li; B. Du; X. Feng; M. Monperrus; E. Tessier; S. Berail; D. Amouroux

    2016-01-01

    Abstract Human consumption of rice constitutes a potential toxicological risk in mercury (Hg) polluted areas such as Hg mining regions in China. It is recognized to be an important source of Hg for the local human diet considering the efficient bioaccumulation of methylmercury (MeHg) in rice seed. To assess Hg sources and uptake pathways to the rice plants, Hg speciation and isotopic composition were investigated in rice seeds and their corresponding paddy soils from different locations withi...

  7. Collective structures in 185Hg

    International Nuclear Information System (INIS)

    Bourgeois, C.; Hildingsson, L.; Perrin, N.; Sergolle, H.; Hannachi, F.; Bastin, G.; Porquet, M.G.; Thibaud, J.P.; Beck, F.A.; Merdinger, J.C.

    1988-01-01

    Excited states of 185 Hg have been investigated via the 161 Dy ( 28 Si, 4n) reaction at 145 MeV. In-beam gamma-ray spectroscopy studies have been performed with the ''Chateau de Cristal'' 4π-multidetector array. Level scheme of 185 Hg has been established. Shape coexistence, still present in 185 Hg like in the neighbouring Hg isotopes, manifests itself through a weakly populated decoupled band built on the 13/2+ isomer and three strongly-coupled bands built on the prolate 1/2-[521], 7/2-[514], and 9/2+[624] Nilsson states

  8. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  9. Identification of the unfavored N=7 superdeformed band in 191Hg

    International Nuclear Information System (INIS)

    Carpenter, M.P.; Janssens, R.V.F.; Cederwall, B.; Crowell, B.; Ahmad, I.; Becker, J.A.; Brinkman, M.J.; Deleplanque, M.A.; Diamond, R.M.; Fallon, P.; Farris, L.P.; Garg, U.; Gassmann, D.; Henry, E.A.; Henry, R.G.; Hughes, J.R.; Khoo, T.L.; Lauritsen, T.; Lee, I.Y.; Machiavelli, A.O.; Moore, E.F.; Nisius, D.; Stephens, F.S.

    1995-01-01

    A new superdeformed band has been identified in 191 Hg bringing the total number of bands observed in this nucleus to four. The new band has properties similar to those of a superdeformed band reported recently in 193 Hg. Both bands are believed to be built on the unfavored signature of the j 15/2 intruder configuration. Comparisons between the data and cranked Woods-Saxon calculations highlight the strengths and weaknesses of theory in describing high-N orbitals at large deformation

  10. Body Burden of Hg in Different Bio-Samples of Mothers in Shenyang City, China

    Science.gov (United States)

    Xu, Jian; Du, Juan; Yan, Chong-huai

    2014-01-01

    Hg is an accumulative and neuro-toxic heavy metal which has a wide range of adverse effects in human health. However, few studies are available on body burden of Hg level in different bio-samples of pregnant women in Chinese population. Therefore, this study evaluated Hg levels in different maternal bio-samples in Shenyang city, China and investigated the correlation of Hg levels in different bio-samples. From October to December 2008, 200 pregnant women about to deliver their babies at ShengJing Hospital (Shenyang city, northeast of China) participated in this study. The geometric mean (GM) of Hg levels in cord blood, maternal venous blood, breast milk, and maternal urine were 2.18 µg/L, 1.17 µg/L, 1.14 µg/L, and 0.73 µg/L, respectively, and the GM of maternal hair Hg level was 404.45 µg/kg. There was a strong correlation between cord blood and maternal blood total Hg level (r = 0.713, PHg exposure (unadjusted OR 3.5, adjusted OR 2.94, PHg burden of mothers and the risk factors of prenatal Hg exposure in Shenyang city, China. PMID:24858815

  11. Influence of pressure changes on recruitment pattern and neck muscle activities during Cranio-Cervical Flexion Tests (CCFTs).

    Science.gov (United States)

    Park, Junhyung; Hur, Jingang; Ko, Taesung

    2015-01-01

    The muscle activity of the deep cervical flexors is emphasized more than that of the superficial cervical flexors, and it has been reported that functional disorders of the longuscolli are found in patients who experience neck pain. The objective of this study was to analyze the recruitment patterns and muscle activities of the cervical flexors during Cranio-Cervical Flexion Tests (CCFTs) through real-time ultrasonography and surface electromyography with a view to presenting appropriate pressure levels for deep cervical flexor exercise protocols based on the results of the analysis. The twenty subjects without neck pain were trained until they became accustomed to CCFTs, and the pressure level was increased gradually from 20 mmHg to 40 mmHg by increasing the pressure level 5 mmHg at a time. Real-time ultrasonography images of the longuscolli and the sternocleidomastoid were taken to measure the amounts of changes in the thicknesses of these muscles, and surface electromyography was implemented to observe the muscle activity of the sternocleidomastoid. The measured value is RMS. According to the results of the ultrasonography, the muscle thicknesses of both the longuscolli and the sternocleidomastoid showed significant increases, as the pressure increased up to 40 mmHg (p< 0.05). The differences in the muscle thicknesses at all individual pressure levels showed significant increases (p< 0.05). According to the results of the electromyography, the muscle activity of the sternocleidomastoid gradually increased as the pressure increased up to 40 mmHg, the increases were significant between 20 mmHg and 25 mmHg, between 30 mmHg and 35 mmHg (p< 0.05). The pressure levels of exercise methods at which the muscle activity of the deep cervical flexors is maximally increased and the muscle activity of the superficial cervical flexors is minimally increased are 25 mmHg-30 mmHg.

  12. Hydro-isomerization of n-hexane on bi-functional catalyst: Effect of total and hydrogen partial pressures

    Science.gov (United States)

    Thoa, Dao Thi Kim; Loc, Luu Cam

    2017-09-01

    The effect of both total pressure and hydrogen partial pressure during n-hexane hydro-isomerization over platinum impregnated on HZSM-5 was studied. n-Hexane hydro-isomerization was conducted at atmospheric pressure and 0.7 MPa to observe the influence of total pressure. In order to see the effect of hydrogen partial pressure, the reaction was taken place at different partial pressure of hydrogen varied from 307 hPa to 718 hPa by dilution with nitrogen to keep the total pressure at 0.1 MPa. Physico-chemical characteristics of catalyst were determined by the methods of nitrogen physi-sorption BET, SEM, XRD, TEM, NH3-TPD, TPR, and Hydrogen Pulse Chemi-sorption. Activity of catalyst in the hydro-isomerization of n-hexane was studied in a micro-flow reactor in the temperature range of 225-325 °C; the molar ratio H2/ hydrocarbon: 5.92, concentration of n-hexane: 9.2 mol.%, GHSV 2698 h-1. The obtained catalyst expressed high acid density, good reducing property, high metal dispersion, and good balance between metallic and acidic sites. It is excellent contact for n-hexane hydro-isomerization. At 250 °C, n-hexane conversion and selectivity were as high as 59-76 % and 85-99 %, respectively. It was found that catalytic activity was promoted either by total pressure or hydrogen partial pressure. At total pressure of 0.7 MPa while hydrogen partial pressure of 718 hPa, catalyst produced 63 RON liquid product containing friendly environmental iso-paraffins which is superior blending stock for green gasoline. Hydrogen did not only preserve catalyst actives by depressing hydrocracking and removing coke precursors but also facilitated hydride transfer step in the bi-functional bi-molecular mechanism.

  13. Effect of fluorination on the structure and superconducting properties of the Hg-1201 phase

    International Nuclear Information System (INIS)

    Abakumov, A.M.; Aleshin, V.A.; Antipov, E.V.; Mikhajlova, D.A.; Putilin, S.N.; Rozova, M.G.; Aksenov, V.L.; Balagurov, A.M.

    1997-01-01

    A fluorination of the reduced Hg-1201 phase with T c =61 K carried out with XeF 2 resulted first in an increase in T c up to 97 K and then in a decrease and even a suppression of superconductivity due to overdoping. Neutron power refinement performed on fluorinated HgBa 2 CuO 4 F δ samples showed twice the amount of extra fluorine (δ≅0.24 and 0.32) in comparison with those for the oxygenated Hg-1201 phases with close T c (δ=0.12 and 0.19). This supports the ionic model of the hole doping in the Hg-1201: 2 holes per extra oxygen and 1 hole per extra fluorine. The exchange of extra oxygen for a double amount of fluorine extends the shortening of the apical Cu-O bond distances, while the in-plane distances, as well as T c , do not vary. These results show that the structural nature of T c variation in Hg-1201 under high pressure can be mainly due to the compression of the in-plane Cu-O bond distances

  14. Blood flow and tissue oxygen pressures of liver and pancreas in rats: effects of volatile anesthetics and of hemorrhage.

    Science.gov (United States)

    Vollmar, B; Conzen, P F; Kerner, T; Habazettl, H; Vierl, M; Waldner, H; Peter, K

    1992-09-01

    The object of this investigation was to compare the effects of volatile anesthetics and of hemorrhage at comparable arterial blood pressures on splanchnic blood flow (radioactive microspheres) and tissue oxygenation of the liver and pancreas (surface PO2 [PSO2] electrodes). In contrast to earlier studies, we did not use identical minimum alveolar anesthetic concentration multiples as a reference to compare volatile anesthetics; rather, we used the splanchnic perfusion pressure. Under general anesthesia (intravenous chloralose) and controlled ventilation, 12 Sprague-Dawley rats underwent laparotomy to allow access to abdominal organs. Mean arterial pressure was decreased from 84 +/- 3 mm Hg (mean +/- SEM) at control to 50 mm Hg by 1.0 +/- 0.1 vol% halothane, 2.2 +/- 0.2 vol% enflurane, and 2.3 +/- 0.1 vol% isoflurane in a randomized sequence. For hemorrhagic hypotension, blood was withdrawn gradually until a mean arterial pressure of 50 mm Hg was attained. Volatile anesthetics and hemorrhage reduced cardiac output, and hepatic arterial, portal venous, and total hepatic blood flows by comparable degrees. Mean hepatic PSO2 decreased significantly from 30.7 +/- 2.6 mm Hg at control to 17.4 +/- 2 and 17.5 +/- 2 mm Hg during enflurane and isoflurane (each P less than 0.05) anesthesia, respectively. The decrease to 11.5 +/- 2.5 mm Hg was more pronounced during halothane anesthesia. Hemorrhagic hypotension was associated with the lowest hepatic PSO2 (3.4 +/- 1.3 mm Hg) and the highest number of hypoxic (0-5 mm Hg 86%) and anoxic PSO2 values (0 mm Hg 46%). Pancreatic blood flow and oxygenation remained unchanged from control during halothane and enflurane administration, whereas isoflurane increased both variables. Hemorrhagic hypotension slightly reduced pancreatic flow (-8%) but significantly decreased PSO2 from 58 +/- 5 mm Hg at control to 36 +/- 3 mm Hg, with 7% of all measured values in the hypoxic range. Thus, volatile anesthetics preserved pancreatic but not hepatic

  15. Exercise-induced albuminuria vs circadian variations in blood pressure in type 1 diabetes.

    Science.gov (United States)

    Tadida Meli, Isabelle Hota; Tankeu, Aurel T; Dehayem, Mesmin Y; Chelo, David; Noubiap, Jean Jacques N; Sobngwi, Eugene

    2017-02-15

    To investigated the relationship between exercise-induced ambulatory blood pressure measurement (ABPM) abnormalities in type 1 diabetes mellitus (T1DM) adolescents. We conducted a case-control at the National Obesity Center of the Yaoundé Central Hospital, Cameroon. We compared 24 h ABPM and urinary albumin-to-creatinine ratio (ACR) at rest and after a standardized treadmill exercise between 20 Cameroonian T1DM patients and 20 matched controls. T1DM adolescents were aged 12-18 years, with diabetes for at least one year, without proteinuria, with normal office blood pressure (BP) and renal function according to the general reference population. Non-diabetic controls were adolescents of general population matched for sex, age and BMI. Mean duration of diabetes was 4.2 ± 2.8 years. The mean 24 h systolic blood pressure (SBP) and diastolic blood pressure (DBP) were respectively 116 ± 9 mmHg in the diabetic group vs 111 ± 8 mmHg in the non-diabetic ( P = 0.06), and 69 ± 7 mm Hg vs 66 ± 5 mm Hg ( P = 0.19). There was no difference in the diurnal pattern of BP in diabetes patients and non-diabetic controls (SBP: 118 ± 10 mmHg vs 114 ± 10 mmHg, P = 0.11; DBP: 71 ± 7 mmHg vs 68 ± 6 mmHg, P = 0.22). Nighttime BP was higher in the diabetic group with respect to SBP (112 ± 11 mmHg vs 106 ± 7 mmHg, P = 0.06) and to the mean arterial pressure (MAP) (89 ± 9 mmHg vs 81 ± 6 mmHg, P = 0.06). ACR at rest was similar in both groups (5.5 mg/g vs 5.5 mg/g, P = 0.74), but significantly higher in diabetes patients after exercise (10.5 mg/g vs 5.5 mg/g, P = 0.03). SBP was higher in patients having exercise-induced albuminuria (116 ± 10 mmHg vs 108 ± 10 mmHg, P = 0.09). Exercise-induced albuminuria could be useful for early diagnosis of kidney damage in adolescents with T1DM.

  16. Body burden of Hg in different bio-samples of mothers in Shenyang city, China.

    Directory of Open Access Journals (Sweden)

    Min-Ming Li

    Full Text Available Hg is an accumulative and neuro-toxic heavy metal which has a wide range of adverse effects in human health. However, few studies are available on body burden of Hg level in different bio-samples of pregnant women in Chinese population. Therefore, this study evaluated Hg levels in different maternal bio-samples in Shenyang city, China and investigated the correlation of Hg levels in different bio-samples. From October to December 2008, 200 pregnant women about to deliver their babies at ShengJing Hospital (Shenyang city, northeast of China participated in this study. The geometric mean (GM of Hg levels in cord blood, maternal venous blood, breast milk, and maternal urine were 2.18 µg/L, 1.17 µg/L, 1.14 µg/L, and 0.73 µg/L, respectively, and the GM of maternal hair Hg level was 404.45 µg/kg. There was a strong correlation between cord blood and maternal blood total Hg level (r = 0.713, P<0.001. Frequency of fish consumption more than or equal to 3 times per week during pregnancy was suggested as a significant risk factor of prenatal Hg exposure (unadjusted OR 3.5, adjusted OR 2.94, P<0.05. This study provides evidence about Hg burden of mothers and the risk factors of prenatal Hg exposure in Shenyang city, China.

  17. A simple sensing mechanism for wireless, passive pressure sensors.

    Science.gov (United States)

    Drazan, John F; Wassick, Michael T; Dahle, Reena; Beardslee, Luke A; Cady, Nathaniel C; Ledet, Eric H

    2016-08-01

    We have developed a simple wireless pressure sensor that consists of only three electrically isolated components. Two conductive spirals are separated by a closed cell foam that deforms when exposed to changing pressures. This deformation changes the capacitance and thus the resonant frequency of the sensors. Prototype sensors were submerged and wirelessly interrogated while being exposed to physiologically relevant pressures from 10 to 130 mmHg. Sensors consistently exhibited a sensitivity of 4.35 kHz/mmHg which is sufficient for resolving physiologically relevant pressure changes in vivo. These simple sensors have the potential for in vivo pressure sensing.

  18. Hg0 and HgCl2 Reference Gas Standards: NIST Traceability and Comparability (And EPA ALT Methods for Hg and HCl )

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the tru...

  19. The systolic blood pressure difference between arms and cardiovascular disease in the Framingham Heart Study.

    Science.gov (United States)

    Weinberg, Ido; Gona, Philimon; O'Donnell, Christopher J; Jaff, Michael R; Murabito, Joanne M

    2014-03-01

    An increased interarm systolic blood pressure difference is an easily determined physical examination finding. The relationship between interarm systolic blood pressure difference and risk of future cardiovascular disease is uncertain. We described the prevalence and risk factor correlates of interarm systolic blood pressure difference in the Framingham Heart Study (FHS) original and offspring cohorts and examined the association between interarm systolic blood pressure difference and incident cardiovascular disease and all-cause mortality. An increased interarm systolic blood pressure difference was defined as ≥ 10 mm Hg using the average of initial and repeat blood pressure measurements obtained in both arms. Participants were followed through 2010 for incident cardiovascular disease events. Multivariable Cox proportional hazards regression analyses were performed to investigate the effect of interarm systolic blood pressure difference on incident cardiovascular disease. We examined 3390 (56.3% female) participants aged 40 years and older, free of cardiovascular disease at baseline, mean age of 61.1 years, who attended a FHS examination between 1991 and 1994 (original cohort) and from 1995 to 1998 (offspring cohort). The mean absolute interarm systolic blood pressure difference was 4.6 mm Hg (range 0-78). Increased interarm systolic blood pressure difference was present in 317 (9.4%) participants. The median follow-up time was 13.3 years, during which time 598 participants (17.6%) experienced a first cardiovascular event, including 83 (26.2%) participants with interarm systolic blood pressure difference ≥ 10 mm Hg. Compared with those with normal interarm systolic blood pressure difference, participants with an elevated interarm systolic blood pressure difference were older (63.0 years vs 60.9 years), had a greater prevalence of diabetes mellitus (13.3% vs 7.5%,), higher systolic blood pressure (136.3 mm Hg vs 129.3 mm Hg), and a higher total cholesterol

  20. Placental Growth Factor Reduces Blood Pressure in a Uteroplacental Ischemia Model of Preeclampsia in Nonhuman Primates.

    Science.gov (United States)

    Makris, Angela; Yeung, Kristen R; Lim, Shirlene M; Sunderland, Neroli; Heffernan, Scott; Thompson, John F; Iliopoulos, Jim; Killingsworth, Murray C; Yong, Jim; Xu, Bei; Ogle, Robert F; Thadhani, Ravi; Karumanchi, S Ananth; Hennessy, Annemarie

    2016-06-01

    An imbalance in the angiogenesis axis during pregnancy manifests as clinical preeclampsia because of endothelial dysfunction. Circulating soluble fms-like tyrosine kinase 1 (sFLT-1) increases and placental growth factor (PlGF) reduces before and during disease. We investigated the clinical and biochemical effects of replenishing the reduced circulating PlGF with recombinant human PlGF (rhPlGF) and thus restoring the angiogenic balance. Hypertensive proteinuria was induced in a nonhuman primate (Papio hamadryas) by uterine artery ligation at 136 days gestation (of a 182-day pregnancy). Two weeks after uteroplacental ischemia, rhPlGF (rhPlGF, n=3) or normal saline (control, n=4) was administered by subcutaneous injection (100 μg/kg per day) for 5 days. Blood pressure was monitored by intra-arterial radiotelemetry and sFLT-1 and PlGF by ELISA. Uteroplacental ischemia resulted in experimental preeclampsia evidenced by increased blood pressure, proteinuria, and endotheliosis on renal biopsy and elevated sFLT-1. PlGF significantly reduced after uteroplacental ischemia. rhPlGF reduced systolic blood pressure in the treated group (-5.2±0.8 mm Hg; from 132.6±6.6 mm Hg to 124.1±7.6 mm Hg) compared with an increase in systolic blood pressure in controls (6.5±3 mm Hg; from 131.3±1.5 mm Hg to 138.6±1.5 mm Hg). Proteinuria reduced in the treated group (-72.7±55.7 mg/mmol) but increased in the control group. Circulating levels of total sFLT-1 were not affected by the administration of PlGF; however, a reduction in placental sFLT-1 mRNA expression was demonstrated. There was no significant difference between the weights or lengths of the neonates in the rhPlGF or control group; however, this study was not designed to assess fetal safety or outcomes. Increasing circulating PlGF by the administration of rhPlGF improves clinical parameters in a primate animal model of experimental preeclampsia. © 2016 American Heart Association, Inc.

  1. Use of new threshold detector 199Hg(n,n')/sup 199m/Hg for neutron spectrum unfolding

    International Nuclear Information System (INIS)

    Sakurai, K.

    1982-01-01

    The nuclear data for the 199 Hg(n,n')/sup 199m/Hg reaction are reviewed and the data are used for neutron spectrum unfolding. The neutron spectrum of the YAYOI glory-hole is unfolded by SAND II with 10 nuclear reactions including the 199 Hg(n,n')/sup 199m/Hg reaction. The ratio of the measured reaction rate to the calculated reaction rate is about 1:1.1 for the guess spectrum. The 199 Hg(n,n')/sup 199m/Hg, 115 In(n,n')/sup 115m/In, 103 Rh(n,n')/sup 103m/Rh reactions should be useful threshold detectors for the neutron dosimetry with low level fast neutron flux

  2. Loci and candidate genes conferring resistance to soybean cyst nematode HG type 2.5.7.

    Science.gov (United States)

    Zhao, Xue; Teng, Weili; Li, Yinghui; Liu, Dongyuan; Cao, Guanglu; Li, Dongmei; Qiu, Lijuan; Zheng, Hongkun; Han, Yingpeng; Li, Wenbin

    2017-06-14

    Soybean (Glycine max L. Merr.) cyst nematode (SCN, Heterodera glycines I,) is a major pest of soybean worldwide. The most effective strategy to control this pest involves the use of resistant cultivars. The aim of the present study was to investigate the genome-wide genetic architecture of resistance to SCN HG Type 2.5.7 (race 1) in landrace and elite cultivated soybeans. A total of 200 diverse soybean accessions were screened for resistance to SCN HG Type 2.5.7 and genotyped through sequencing using the Specific Locus Amplified Fragment Sequencing (SLAF-seq) approach with a 6.14-fold average sequencing depth. A total of 33,194 SNPs were identified with minor allele frequencies (MAF) over 4%, covering 97% of all the genotypes. Genome-wide association mapping (GWAS) revealed thirteen SNPs associated with resistance to SCN HG Type 2.5.7. These SNPs were distributed on five chromosomes (Chr), including Chr7, 8, 14, 15 and 18. Four SNPs were novel resistance loci and nine SNPs were located near known QTL. A total of 30 genes were identified as candidate genes underlying SCN resistance. A total of sixteen novel soybean accessions were identified with significant resistance to HG Type 2.5.7. The beneficial alleles and candidate genes identified by GWAS might be valuable for improving marker-assisted breeding efficiency and exploring the molecular mechanisms underlying SCN resistance.

  3. The application of 199Hg NMR and 199mHg perturbed angular correlation (PAC) spectroscopy to define the biological chemistry of HgII

    DEFF Research Database (Denmark)

    Iranzo, Olga; Thulstrup, Peter Waaben; Ryu, Seung-baek

    2007-01-01

    The use of de novo designed peptides is a powerful strategy to elucidate HgII-protein interactions and to gain insight into the chemistry of HgII in biological systems. Cysteine derivatives of the designed -helical peptides of the TRI family [Ac-G-(LaKbAcLdEeEfKg)4-G-NH2] bind HgII at high p...... to characterize the distinct species that are generated under different pH conditions and peptide TRI L9C/HgII ratios. These studies prove for the first time the formation of [Hg{(TRI L9C)2-(TRI L9C H)}], a dithiolate-HgII complex in the hydrophobic interior of the three-stranded coiled coil (TRI L9C)3. 199Hg NMR...

  4. Long-term Hg pollution induced Hg tolerance in the terrestrial isopod Porcellio scaber (Isopoda, Crustacea)

    International Nuclear Information System (INIS)

    Lapanje, A.; Drobne, D.; Nolde, N.; Valant, J.; Muscet, B.; Leser, V.; Rupnik, M.

    2008-01-01

    The aim of our work was to assess the pollution-induced community tolerance (PICT) of isopod gut microbiota and pollution-induced isopod population tolerance (PIPT). Animals collected from a chronically Hg polluted and an unpolluted location were exposed for 14 days to 10 μg Hg/g dry food under laboratory conditions. The lysosomal membrane stability, hepatopancreas epithelium thickness, feeding activity and animal bacterial gut microbiota composition were determined. The results confirm the hypothesis that the response to short-term Hg exposure differs for animals from the Hg polluted and the unpolluted field locations. The animals and their gut microbiota from the Hg polluted location were less affected by Hg in a short-term feeding experiment than those from the unpolluted environment. We discuss the pollution-induced population tolerance of isopods and their gut microbiota as a measure of effects of long-term environmental pollution. The ecological consequences of such phenomena are also discussed. - Isopods (Porcellio scaber) as well as their bacterial gut community from a mercury-polluted site are mercury tolerant

  5. Long-term Hg pollution induced Hg tolerance in the terrestrial isopod Porcellio scaber (Isopoda, Crustacea)

    Energy Technology Data Exchange (ETDEWEB)

    Lapanje, A. [University of Ljubljana, Biotechnical Faculty, Department of Biology, Vecna pot 111, 1000 Ljubljana (Slovenia); Institute of Physical Biology, Veliko Mlacevo 59, 1290 Grosuplje (Slovenia)], E-mail: ales.lapanje@bf.uni-lj.si; Drobne, D. [University of Ljubljana, Biotechnical Faculty, Department of Biology, Vecna pot 111, 1000 Ljubljana (Slovenia); Nolde, N. [Institute Jozef Stefan, Department of Environmental Sciences, Jamova 39, 1000 Ljubljana (Slovenia); Valant, J. [University of Ljubljana, Biotechnical Faculty, Department of Biology, Vecna pot 111, 1000 Ljubljana (Slovenia); Muscet, B. [Institute of Physical Biology, Veliko Mlacevo 59, 1290 Grosuplje (Slovenia); Leser, V. [University of Ljubljana, Biotechnical Faculty, Department of Biology, Vecna pot 111, 1000 Ljubljana (Slovenia); Rupnik, M. [Institute of Public Health, Prvomajska 1, 2000 Maribor (Slovenia); Faculty of Medicine, University of Maribor, Slomskov trg 15, 2000 Maribor (Slovenia)

    2008-06-15

    The aim of our work was to assess the pollution-induced community tolerance (PICT) of isopod gut microbiota and pollution-induced isopod population tolerance (PIPT). Animals collected from a chronically Hg polluted and an unpolluted location were exposed for 14 days to 10 {mu}g Hg/g dry food under laboratory conditions. The lysosomal membrane stability, hepatopancreas epithelium thickness, feeding activity and animal bacterial gut microbiota composition were determined. The results confirm the hypothesis that the response to short-term Hg exposure differs for animals from the Hg polluted and the unpolluted field locations. The animals and their gut microbiota from the Hg polluted location were less affected by Hg in a short-term feeding experiment than those from the unpolluted environment. We discuss the pollution-induced population tolerance of isopods and their gut microbiota as a measure of effects of long-term environmental pollution. The ecological consequences of such phenomena are also discussed. - Isopods (Porcellio scaber) as well as their bacterial gut community from a mercury-polluted site are mercury tolerant.

  6. MRI measurements of intracranial pressure in the upright posture: The effect of the hydrostatic pressure gradient.

    Science.gov (United States)

    Alperin, Noam; Lee, Sang H; Bagci, Ahmet M

    2015-10-01

    To add the hydrostatic component of the cerebrospinal fluid (CSF) pressure to magnetic resonance imaging (MRI)-derived intracranial pressure (ICP) measurements in the upright posture for derivation of pressure value in a central cranial location often used in invasive ICP measurements. Additional analyses were performed using data previously collected from 10 healthy subjects scanned in supine and sitting positions with a 0.5T vertical gap MRI scanner (GE Medical). Pulsatile blood and CSF flows to and from the brain were quantified using cine phase-contrast. Intracranial compliance and pressure were calculated using a previously described method. The vertical distance between the location of the CSF flow measurement and a central cranial location was measured manually in the mid-sagittal T1 -weighted image obtained in the upright posture. The hydrostatic pressure gradient of a CSF column with similar height was then added to the MR-ICP value. After adjustment for the hydrostatic component, the mean ICP value was reduced by 7.6 mmHg. Mean ICP referenced to the central cranial level was -3.4 ± 1.7 mmHg compared to the unadjusted value of +4.3 ± 1.8 mmHg. In the upright posture, the hydrostatic pressure component needs to be added to the MRI-derived ICP values for compatibility with invasive ICP at a central cranial location. © 2015 Wiley Periodicals, Inc.

  7. Early in vivo experience with the pediatric continuous-flow total artificial heart.

    Science.gov (United States)

    Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Kuban, Barry D; Gao, Shengqiang; Dessoffy, Raymond; Fukamachi, Kiyotaka

    2018-03-30

    Heart transplantation in infants and children is an accepted therapy for end-stage heart failure, but donor organ availability is low and always uncertain. Mechanical circulatory support is another standard option, but there is a lack of intracorporeal devices due to size and functional range. The purpose of this study was to evaluate the in vivo performance of our initial prototype of a pediatric continuous-flow total artificial heart (P-CFTAH), comprising a dual pump with one motor and one rotating assembly, supported by a hydrodynamic bearing. In acute studies, the P-CFTAH was implanted in 4 lambs (average weight: 28.7 ± 2.3 kg) via a median sternotomy under cardiopulmonary bypass. Pulmonary and systemic pump performance parameters were recorded. The experiments showed good anatomical fit and easy implantation, with an average aortic cross-clamp time of 98 ± 18 minutes. Baseline hemodynamics were stable in all 4 animals (pump speed: 3.4 ± 0.2 krpm; pump flow: 2.1 ± 0.9 liters/min; power: 3.0 ± 0.8 W; arterial pressure: 68 ± 10 mm Hg; left and right atrial pressures: 6 ± 1 mm Hg, for both). Any differences between left and right atrial pressures were maintained within the intended limit of ±5 mm Hg over a wide range of ratios of systemic-to-pulmonary vascular resistance (0.7 to 12), with and without pump-speed modulation. Pump-speed modulation was successfully performed to create arterial pulsation. This initial P-CFTAH prototype met the proposed requirements for self-regulation, performance, and pulse modulation. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  8. Total dietary intake of mercury in the Canary Islands, Spain.

    Science.gov (United States)

    Rubio, C; Gutiérrez, A; Burgos, A; Hardisson, A

    2008-08-01

    Estimating the risk associated with dietary intake of heavy metals by consumers is a vital and integral part of regulatory processes. The assessment of exposure to mercury shown in this paper has been performed by means of a study on the whole diet. Total mercury (Hg) levels were determined by cold vapour atomic absorption spectrometry (AAS) in 420 samples of regularly consumed food and drink. The total Hg concentrations measured in the different groups of food ranged from non-detectable to 119 microg kg(-1) w/w. The fish group had the highest concentrations of total Hg. All groups of food with regulated Hg content showed levels that were lower than the legally set values. The food consumption data used in the analysis were taken from the latest nutritional survey made in the Canary Islands, Spain. The estimated total Hg intake of local population (5.7 microg/person day(-1)) did not exceed the provisional tolerable weekly intake (PTWI) limit of 0.3 mg week(-1) of total mercury (43 microg/person day(-1)) fixed by the Joint Food and Agricultural Organization/World Health Organization (FAO/WHO) Expert Committee on Food Additives. Fishery products contributed 96% of the total Hg intake. The mean Hg intake for each island in this archipelago, formed by seven, has also been calculated. Fuerteventura, Lanzarote and El Hierro are the islands with the highest level of Hg intake (7.0, 7,0 and 6.1 microg/person day(-1), respectively). La Palma Island, due to its low fish consumption, had the lowest level of Hg intake (4.5 microg/person day(-1)), followed by La Gomera (5.4 microg/person day(-1)), Tenerife (5.5 microg/person day(-1)) and Gran Canaria (5.6 microg/person day(-1)). A comparison has been made of the results obtained in this study with those found for other national and international communities.

  9. Low vs Standard Pressures in Gynecologic Laparoscopy: a Systematic Review.

    Science.gov (United States)

    Kyle, Esther B; Maheux-Lacroix, Sarah; Boutin, Amélie; Laberge, Philippe Y; Lemyre, Madeleine

    2016-01-01

    The optimal intraperitoneal pressure during laparoscopy is not known. Recent literature found benefits of using lower pressures, but the safety of doing abdominal surgery with low peritoneal pressures needs to be assessed. This systematic review compares low with standard pneumoperitoneum during gynecologic laparoscopy. We searched Medline, Embase, and the Cochrane Library for randomized controlled trials comparing intraperitoneal pressures during gynecologic laparoscopy. Two authors reviewed references and extracted data from included trials. Risk ratios, mean differences, and standard mean differences were calculated and pooled using RevMan5. Of 2251 studies identified, three were included in the systematic review, for a total of 238 patients. We found a statistically significant but modest diminution in postoperative pain of 0.38 standardized unit based on an original 10-point scale (95% confidence interval [CI], -0.67 to -0.08) during the immediate postoperative period when using low intraperitoneal pressure of 8 mm Hg compared with ≥ 12 mm Hg and of 0.50 (95% CI, -0.80 to -0.21) 24 hours after the surgery. Lower pressures were associated with worse visualization of the surgical field (risk ratio, 10.31; 95% CI, 1.29-82.38). We found no difference between groups over blood loss, duration of surgery, hospital length of stay, or the need for increased pressure. Low intraperitoneal pressures during gynecologic laparoscopy cannot be recommended on the behalf of this review because improvement in pain scores is minimal and visualization of the surgical field is affected. The safety of this intervention as well as cost-effectiveness considerations need to be further studied.

  10. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  11. Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.

    Science.gov (United States)

    Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji

    2010-04-01

    To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.

  12. Intraocular pressure in very low birth weight preterm infants and its association with postconceptional age

    Directory of Open Access Journals (Sweden)

    Rodrigo L. Lindenmeyer

    2012-11-01

    Full Text Available OBJECTIVE: To evaluate intraocular pressure in very low birth weight preterm infants and correlate it with postconceptional age. METHODS: The intraocular pressure in a prospective cohort of very low birth weight premature infants (defined as a birth weight <1,500 g and gestational age <32 weeks admitted to Hospital de Clínicas de Porto Alegre , Brazil was evaluated weekly. The evaluated outcome was the variation in the intraocular pressure following changes in the postconceptional age (defined as the gestational age at birth plus the age in weeks at the time of examination in the weeks following preterm birth. Mixed-effects models were used for the statistical analysis to determine the intraocular pressure variation according to postconceptional age, and means and 10th and 90th percentiles were calculated for the intraocular pressure values. RESULTS: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and a mean birth weight of 1,127.7 ± 222.7 g were evaluated. The mean intraocular pressure for the entire cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of all recorded intraocular pressure values were greater than 20 mmHg. The analysis revealed a mean reduction in the intraocular pressure of 0.29 mmHg for each increase in postconceptional age (p = 0.047; 95% CI: -0.58 to -0.0035. The mean intraocular pressure (P10-P90 decreased from 16.3 mmHg (10.5222.16 at 26.3 weeks to 13.1 mmHg (7.28-18.92 at 37.6 weeks of postconceptional age. CONCLUSIONS: The mean intraocular pressure in very low birth weight preterm infants was 14.9 ± 4.5 mmHg. This value decreased 0.29 mmHg per week as the postconceptional age increased.

  13. HgTe based topological insulators

    International Nuclear Information System (INIS)

    Bruene, Christoph

    2014-01-01

    This PhD thesis summarizes the discovery of topological insulators and highlights the developments on their experimental observations. The work focuses on HgTe. The thesis is structured as follows: - The first chapter of this thesis will give a brief overview on discoveries in the field of topological insulators. It focuses on works relevant to experimental results presented in the following chapters. This includes a short outline of the early predictions and a summary of important results concerning 2-dimensional topological insulators while the final section discusses observations concerning 3-dimensional topological insulators. - The discovery of the quantum spin Hall effect in HgTe marked the first experimental observation of a topological insulator. Chapter 2 focuses on HgTe quantum wells and the quantum spin Hall effect. The growth of high quality HgTe quantum wells was one of the major goals for this work. In a final set of experiments the spin polarization of the edge channels was investigated. Here, we could make use of the advantage that HgTe quantum well structures exhibit a large Rashba spin orbit splitting. - HgTe as a 3-dimensional topological insulator is presented in chapter 3. - Chapters 4-6 serve as in depth overviews of selected works: Chapter 4 presents a detailed overview on the all electrical detection of the spin Hall effect in HgTe quantum wells. The detection of the spin polarization of the quantum spin Hall effect is shown in chapter 5 and chapter 6 gives a detailed overview on the quantum Hall effect originating from the topological surface state in strained bulk HgTe.

  14. Interim pressure garment therapy (4-6 mmHg) and its effect on donor site healing in burn patients: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Donovan, Michelle L; Muller, Michael J; Simpson, Claire; Rudd, Michael; Paratz, Jennifer

    2016-04-26

    Pressure garment therapy (PGT) is well accepted and commonly used by clinicians in the treatment of burns scars and grafts. The medium to high pressures (24-40 mmHg) in these garments can support scar minimisation, and evidence is well documented for this particular application. However, PGT specifically for burn donor sites, of which a sequela is also scarring, is not well documented. This study protocol investigates the impact of a low pressure (4-6 mmHg) interim garment on donor site healing and scarring. With a primary purpose of holding donor dressings in place, the application of the interim pressure garment (IPG) appears to have been twofold. IPGs for donor sites have involved inconsistent application with a focus on securing wound dressing rather than scar management. However, anecdotal and observational evidence suggests that IPGs also make a difference to some patient's scar outcomes for donor sites. This study protocol outlines a randomised controlled trial designed to test the effectiveness of this treatment on reducing scarring to burn donor sites. This study is a single-centre, single (assessor)-blinded, randomised control trial in patients with burns donor sites to their thighs. Patients will be randomly allocated to a control group (with no compression to donor sites) or to an experimental group (with compression to donor sites) as the comparative treatment. Groups will be compared at baseline regarding the important prognostic indicators: donor site location, depth, size, age, and time since graft (5 days). The IPG treatment will be administered post-operatively (on day 5). Follow-up assessments and garment replacement will be undertaken fortnightly for a period of 2 months. This study focuses on a unique area of burns scar management using a low-pressure tubular support garment for the reduction of donor site scars. Such therapy specifically for donor scar management is poorly represented in the literature. This study was designed to test a

  15. Determination of total selenium and selenium distribution in the milk phases in commercial cow's milk by HG-AAS

    Energy Technology Data Exchange (ETDEWEB)

    Muniz-Naveiro, Oscar; Dominguez-Gonzalez, Raquel; Bermejo-Barrera, Adela; Bermejo-Barrera, Pilar [University of Santiago de Compostela, Department of Analytical Chemistry, Nutrition and Bromatology, Santiago de Compostela (Spain); Cocho, Jose A. [University Clinical Hospital, Laboratory of Metabolic and Nutritional Disorders, Santiago de Compostela (Spain); Fraga, Jose M. [University Clinical Hospital, Department of Pediatrics, Santiago de Compostela (Spain)

    2005-03-01

    A procedure has been developed for determining the selenium in cow's milk using hydride generation-atomic absorption spectrometry (HG-AAS) following microwave-assisted acid digestion. The selenium distributions in milk whey, fat and micellar casein phases were studied after separating the different phases by ultracentrifugation and determining the selenium in all of them. The detection limits obtained by HG-AAS for the whole milk, milk whey and micellar casein were 0.074, 0.065 and 0.075 {mu}g l{sup -1}, respectively. The accuracy for the whole milk was checked by using a Certified Reference Material CRM 8435 whole milk powder from NIST, and the analytical recoveries for the milk whey and casein micelles were 100.9 and 96.9%, respectively. A mass balance study of the determination of selenium in the different milk phases was carried out, obtaining values of 95.5-100.8%. The total content of selenium was determined in 37 milk samples from 15 different manufacturers, 19 whole milk samples and 18 skimmed milk samples. The selenium levels found were within the 8.5-21 {mu}g l{sup -1} range. The selenium distributions in the different milk phases were studied in 14 whole milk samples, and the highest selenium levels were found in milk whey (47.2-73.6%), while the lowest level was found for the fat phase (4.8-16.2%). A strong correlation was found between the selenium levels in whole milk and the selenium levels in the milk components. (orig.)

  16. Effect of Antihypertensive Therapy on SCORE-Estimated Total Cardiovascular Risk: Results from an Open-Label, Multinational Investigation—The POWER Survey

    Directory of Open Access Journals (Sweden)

    Guy De Backer

    2013-01-01

    Full Text Available Background. High blood pressure is a substantial risk factor for cardiovascular disease. Design & Methods. The Physicians' Observational Work on patient Education according to their vascular Risk (POWER survey was an open-label investigation of eprosartan-based therapy (EBT for control of high blood pressure in primary care centers in 16 countries. A prespecified element of this research was appraisal of the impact of EBT on estimated 10-year risk of a fatal cardiovascular event as determined by the Systematic Coronary Risk Evaluation (SCORE model. Results. SCORE estimates of CVD risk were obtained at baseline from 12,718 patients in 15 countries (6504 men and from 9577 patients at 6 months. During EBT mean (±SD systolic/diastolic blood pressures declined from 160.2 ± 13.7/94.1 ± 9.1 mmHg to 134.5 ± 11.2/81.4 ± 7.4 mmHg. This was accompanied by a 38% reduction in mean SCORE-estimated CVD risk and an improvement in SCORE risk classification of one category or more in 3506 patients (36.6%. Conclusion. Experience in POWER affirms that (a effective pharmacological control of blood pressure is feasible in the primary care setting and is accompanied by a reduction in total CVD risk and (b the SCORE instrument is effective in this setting for the monitoring of total CVD risk.

  17. Effect of Antihypertensive Therapy on SCORE-Estimated Total Cardiovascular Risk: Results from an Open-Label, Multinational Investigation—The POWER Survey

    Science.gov (United States)

    De Backer, Guy; Petrella, Robert J.; Goudev, Assen R.; Radaideh, Ghazi Ahmad; Rynkiewicz, Andrzej; Pathak, Atul

    2013-01-01

    Background. High blood pressure is a substantial risk factor for cardiovascular disease. Design & Methods. The Physicians' Observational Work on patient Education according to their vascular Risk (POWER) survey was an open-label investigation of eprosartan-based therapy (EBT) for control of high blood pressure in primary care centers in 16 countries. A prespecified element of this research was appraisal of the impact of EBT on estimated 10-year risk of a fatal cardiovascular event as determined by the Systematic Coronary Risk Evaluation (SCORE) model. Results. SCORE estimates of CVD risk were obtained at baseline from 12,718 patients in 15 countries (6504 men) and from 9577 patients at 6 months. During EBT mean (±SD) systolic/diastolic blood pressures declined from 160.2 ± 13.7/94.1 ± 9.1 mmHg to 134.5 ± 11.2/81.4 ± 7.4 mmHg. This was accompanied by a 38% reduction in mean SCORE-estimated CVD risk and an improvement in SCORE risk classification of one category or more in 3506 patients (36.6%). Conclusion. Experience in POWER affirms that (a) effective pharmacological control of blood pressure is feasible in the primary care setting and is accompanied by a reduction in total CVD risk and (b) the SCORE instrument is effective in this setting for the monitoring of total CVD risk. PMID:23997946

  18. The Relationship Between Preoperative and Primary Care Blood Pressure Among Veterans Presenting from Home for Surgery. Is There Evidence for Anesthesiologist-Initiated Blood Pressure Referral?

    Science.gov (United States)

    Schonberger, Robert B.; Burg, Matthew M.; Holt, Natalie; Lukens, Carrie L.; Dai, Feng; Brandt, Cynthia

    2011-01-01

    Background American College of Cardiology/American Heart Association guidelines describe the perioperative evaluation as “a unique opportunity to identify patients with hypertension,” however factors such as anticipatory stress or medication noncompliance may induce a bias toward higher blood pressure, leaving clinicians unsure about how to interpret preoperative hypertension. Information describing the relationship between preoperative intake blood pressure and primary care measurements could help anesthesiologists make primary care referrals for improved blood pressure control in an evidence-based fashion. We hypothesized that the preoperative examination provides a useful basis for initiating primary care blood pressure referral. Methods We analyzed retrospective data on 2807 patients who arrived from home for surgery and who were subsequently evaluated within 6 months after surgery in the primary care center of the same institution. After descriptive analysis, we conducted multiple linear regression analysis to identify day-of-surgery (DOS) factors associated with subsequent primary care blood pressure. We calculated the sensitivity, specificity, and positive and negative predictive value of different blood pressure referral thresholds using both a single-measurement and a two-stage screen incorporating recent preoperative and DOS measurements for identifying patients with subsequently elevated primary care blood pressure. Results DOS systolic blood pressure (SBP) was higher than subsequent primary care SBP by a mean bias of 5.5mmHg (95% limits of agreement +43.8 to −32.8). DOS diastolic blood pressure (DBP) was higher than subsequent primary care DBP by a mean bias of 1.5mmHg (95% limits of agreement +13.0 to −10.0). Linear regression of DOS factors explained 19% of the variability in primary care SBP and 29% of the variability in DBP. Accounting for the observed bias, a two-stage SBP referral screen requiring preoperative clinic SBP≥140mmHg and DOS

  19. A Calibrated Method of Massage Therapy Decreases Systolic Blood Pressure Concomitant With Changes in Heart Rate Variability in Male Rats.

    Science.gov (United States)

    Spurgin, Kurt A; Kaprelian, Anthony; Gutierrez, Roberto; Jha, Vidyasagar; Wilson, Christopher G; Dobyns, Abigail; Xu, Karen H; Curras-Collazo, Margarita C

    2017-02-01

    The purpose of this study was to develop a method for applying calibrated manual massage pressures by using commonly available, inexpensive sphygmomanometer parts and validate the use of this approach as a quantitative method of applying massage therapy to rodents. Massage pressures were monitored by using a modified neonatal blood pressure (BP) cuff attached to an aneroid gauge. Lightly anesthetized rats were stroked on the ventral abdomen for 5 minutes at pressures of 20 mm Hg and 40 mm Hg. Blood pressure was monitored noninvasively for 20 minutes following massage therapy at 5-minute intervals. Interexaminer reliability was assessed by applying 20 mm Hg and 40 mm Hg pressures to a digital scale in the presence or absence of the pressure gauge. With the use of this method, we observed good interexaminer reliability, with intraclass coefficients of 0.989 versus 0.624 in blinded controls. In Long-Evans rats, systolic BP dropped by an average of 9.86% ± 0.27% following application of 40 mm Hg massage pressure. Similar effects were seen following 20 mm Hg pressure (6.52% ± 1.7%), although latency to effect was greater than at 40 mm Hg. Sprague-Dawley rats behaved similarly to Long-Evans rats. Low-frequency/high-frequency ratio, a widely-used index of autonomic tone in cardiovascular regulation, showed a significant increase within 5 minutes after 40 mm Hg massage pressure was applied. The calibrated massage method was shown to be a reproducible method for applying massage pressures in rodents and lowering BP. Copyright © 2016. Published by Elsevier Inc.

  20. Effects of Topical Phenylephrine HCl 2.5% used before Cataract Surgery on Systemic Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emre Ayıntap

    2011-06-01

    Full Text Available Purpose: To evaluate the effect of topical phenylephrine HCl 2.5% (Mydfrin, used as a fast and effective mydriatic before cataract surgery, on systemic blood pressure. Material and Method: Topical phenylephrine HCl 2.5% was administered 3 times with 5-minute intervals before cataract surgery to 44 eyes of 44 patients. The systemic blood pressure was measured preoperatively and at 15 and 30 minutes. Results: The mean systolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 119.7mmHg, while 15 and 30 minutes later, it was 125.3 mmHg and 121.2 mmHg, respectively. The mean diastolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 75.9 mmHg; 15 and 30 minutes later, it was 76.9 mmHg and 75.3 mmHg, respectively. The increase in systolic blood pressure at 15 and 30 minutes was statistically significant (p=0.003 and p=0.042. The change in diastolic blood pressure was not statistically significant. Discussion: Phenylephrine HCl 2.5%, which is used preoperatively as a fast and effective mydriatic for cataract surgery, can increase the systolic blood pressure. This effect is most significant at 15 minutes and lasts at least 30 minutes. This agent should be used with care in hypertensive patients. (Turk J Ophthalmol 2011; 41: 164-6

  1. Validation of the iHealth BP5 wireless upper arm blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Shang, Fujun; Zhu, Yizheng; Zhu, Zhenlai; Liu, Lei; Wan, Yi

    2013-10-01

    The aim of this study was to validate the iHealth BP5 wireless upper arm blood pressure (BP) monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010. The ESH-IP revision 2010 for validation of BP measuring devices in adults was followed precisely. A total of 99 pairs of test device and reference BP measurements (three pairs for each of the 33 participants) were obtained in the study. The device produced 71, 89, and 97 measurements within 5, 10, and 15 mmHg for systolic blood pressure (SBP) and 73, 90, and 99 mmHg for diastolic blood pressure (DBP), respectively. The mean ± SD device-observer difference was -1.21 ± 5.87 mmHg for SBP and -1.04 ± 5.28 mmHg for DBP. The number of participants with two or three device-observer differences within 5 mmHg was 25 for SBP and 28 for DBP. In addition, three participants had no device-observer difference within 5 mmHg for SBP and none of the participants had the same for DBP. According to the validation results on the basis of the ESH-IP revision 2010, the iHealth BP5 wireless upper arm BP monitor can be recommended for self/home measurement in an adult population.

  2. Blood pressure changes in dogs with babesiosis

    Directory of Open Access Journals (Sweden)

    L.S. Jacobson

    2000-07-01

    Full Text Available Systemic arterial blood pressures were measured in 30 dogs with acute babesiosis, 10 each with mild uncomplicated, severe uncomplicated and complicated disease. Ten healthy dogs were used as controls. Hypotension was defined as more than 3 standard deviations below the control mean. Normal mean pressures (±SD were: systolic arterial pressure 151 (±11 mm Hg, diastolic arterial pressure 89 (±8 mm Hg and mean arterial pressure 107 (±10 mmHg. Hypotension was the most frequent abnormality, and increased strikingly in incidence as disease severity increased, with 5/10 dogs in the complicated group being hypotensive for systolic, diastolic and mean arterial pressures, compared with 2/10 in the severe uncomplicated group and 0/10 in the mild uncomplicated group. Systolic, diastolic and mean arterial pressures in the complicated group and severe uncomplicated group, and systolic pressure in the mild uncomplicated group, were significantly lower than in the controls. There were no significant relationships between arterial pressures and age, pulse rate, respiratory rate, temperature, mucous membrane colour or haematocrit. There was a significant negative correlation between arterial pressures and white cell and immature neutrophil counts. Arterial pressures differed significantly between dogs that were clinically collapsed and those that were not, but not between survivors and non-survivors. Pulse pressure (systolic - diastolic was low in 7/10 complicated, 1/10 mild uncomplicated, and 1/10 severe uncomplicated cases, and differed significantly between the complicated and control groups. The high incidence of hypotension in clinically severe babesiosis has important implications for therapy.

  3. [Changes in intraocular pressure depending on posture].

    Science.gov (United States)

    Barac, Ramona; Pop, Monica; Tătaru, C; Gheorghe, A; Bădescu, Silvia; Stanciu, Maria; Burcea, M

    2014-01-01

    Glaucoma is an important eye disease that, left untreated, causes irreversible blindness by affecting optic nerve threads. Decreasing intraocular pressure and maintaining it at a low level throughout the day is one of the objectives of antiglaucoma therapy. This is a prospective study conducted on a sample of 80 patients who presented at "Emergency Eye Hospital" Bucharest between 1st of December 2013 30th of July 2014. Patients were divided into two groups: 40 patients with glaucoma and 40 patients without glaucoma (control group). THE OBJECTIVE OF THE STUDY: To determine changes in intraocular pressure that may occur depending on body posture and the correlations between changes in intraocular pressure and glaucoma, obesity, hypertension. These IOP changes may be important in the progression of glaucoma regarding that one third of our time is spent on supine position during night. RESULTS AND CONCLUZIONS: IOP varies from sitting down to supine position. IOP increases in supine in most patients (with or without glaucoma) with an average of 1.25 mmHg. The increase among patients with glaucoma is higher (1.67 mmHg) compared to those without glaucoma (0.82 mmHg). In patients with hypertension and glaucoma, IOP increased with 2.62 mmHg. In patients with hypertension and obesity IOP increased with 2.5 mmHg.

  4. Sudden change of quadrupole moment between the first 5/2- states of 197Hg and 199Hg

    International Nuclear Information System (INIS)

    Herzog, P.; Krien, K.; Freitag, M.; Reuschenbach, M.; Walitzki, H.

    1980-01-01

    Low-temperature time differential perturbed angular correlation experiments with the 164 KeV-134 keV cascade of sup(197m)Hg in a zinc matrix give evidence that the hitherto accepted value of the quadrupole moment of the first 5/2 - state of 197 Hg is erroneous. A new value is derived from a time differential perturbed angular correlation experiment with the 374 keV-158 keV cascade of sup(199m)Hg implanted into a Be single crystal and comparison with an analogous experiment for sup(197m)Hg. Taking Q(5/2 - , 199 Hg) = +0.95(7) b we derive Q(5/2 - , 197 Hg) = 0.081(6) b. This change of quadrupole moment is discussed in the framework of the shell model. (orig.)

  5. Research on axial total pressure distributions of sonic steam jet in subcooled water

    International Nuclear Information System (INIS)

    Wu Xinzhuang; Li Wenjun; Yan Junjie

    2012-01-01

    The axial total pressure distributions of sonic steam jet in subcooled water were experimentally investigated for three different nozzle diameters (6.0 mm, 8.0 mm and 10.0 mm). The inlet steam pressure, and pool subcooling subcooled water temperature were in the range of 0.2-0.6 MPa and 420-860 ℃, respectively. The effect of steam pressure, subcooling water temperature and nozzle size on the axial pressure distributions were obtained, and also the characteristics of the maximum pressure and its position were studied. The results indicated that the characteristics of the maximum pressure were influenced by the nozzle size for low steam pressure, but the influence could be ignored for high steam pressure. Moreover, a correlation was given to correlate the position of the maximum pressure based on steam pressure and subcooling water temperature, and the discrepancies of predictions and experiments are within ±15%. (authors)

  6. Validation of the Pangao PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.

    Science.gov (United States)

    Zhao, Hairong; Qiao, Weichang; Zhang, Rui; Cui, Peng; Hou, Fanglin; Zhang, Wenli

    2018-02-01

    The aim of this study was to validate the PG-800A36 automatic wrist blood pressure monitor according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010 and the British Hypertension Society (BHS) protocols. A total of 33 participants were initially included on the basis of the ESH-IP, followed by examination of 85 participants according to the BHS protocol. The procedures and analysis methods of the protocols were followed precisely with left arm/wrist sequential measurements by two trained observers using a mercury sphygmomanometer and one supervisor using the device. The device passed the ESH-IP with an average difference of 1.45±6.46 mmHg for systolic blood pressure and 1.25±5.10 mmHg for diastolic blood pressure. Furthermore, the A/A grade of the BHS protocol was achieved with an average difference of 1.84±6.94 mmHg for systolic blood pressure and 1.15±6.49 mmHg for diastolic blood pressure, and thus, the device also fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The Pangao PG-800A36 passed the requirements of the ESH-IP revision 2010 and achieved the A/A grade of the BHS protocol, which can be recommended for self-measurement in the general population.

  7. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Zhang, Yi; Wang, Jie; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2009-06-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor LD-578 (HONSUN Group, Shanghai, China) for home blood pressure monitoring according to the International Protocol. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese using a mercury sphygmomanometer (two observers) and the LD-578 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was performed using the ESHIP Analyzer. The LD-578 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 32 of 45, 41 of 45, and 45 of 45 measurements (required 25, 35, and 40), respectively. The device also achieved the targets for phase 2.1, with 67 of 99, 90 of 99, and 98 of 99 differences within 5, 10, and 15 mmHg, respectively, for systolic blood pressure, and with 69 of 99, 95 of 99, and 98 of 99 within 5, 10, and 15 mmHg, respectively, for diastolic blood pressure. In phase 2.2, 24 participants had at least two of the three device-observers differences within 5 mmHg (required >or=22) for systolic and diastolic blood pressure. The HONSUN upper arm blood pressure monitor LD-578 can be recommended for home use in adults.

  8. Acute post-stroke blood pressure relative to premorbid levels in intracerebral haemorrhage versus major ischaemic stroke: a population-based study

    Science.gov (United States)

    Fischer, Urs; Cooney, Marie Therese; Bull, Linda M; Silver, Louise E; Chalmers, John; Anderson, Craig S; Mehta, Ziyah; Rothwell, Peter M

    2014-01-01

    Summary Background It is often assumed that blood pressure increases acutely after major stroke, resulting in so-called post-stroke hypertension. In view of evidence that the risks and benefits of blood pressure-lowering treatment in acute stroke might differ between patients with major ischaemic stroke and those with primary intracerebral haemorrhage, we compared acute-phase and premorbid blood pressure levels in these two disorders. Methods In a population-based study in Oxfordshire, UK, we recruited all patients presenting with stroke between April 1, 2002, and March 31, 2012. We compared all acute-phase post-event blood pressure readings with premorbid readings from 10-year primary care records in all patients with acute major ischaemic stroke (National Institutes of Health Stroke Scale >3) versus those with acute intracerebral haemorrhage. Findings Of 653 consecutive eligible patients, premorbid and acute-phase blood pressure readings were available for 636 (97%) individuals. Premorbid blood pressure (total readings 13 244) had been measured on a median of 17 separate occasions per patient (IQR 8–31). In patients with ischaemic stroke, the first acute-phase systolic blood pressure was much lower than after intracerebral haemorrhage (158·5 mm Hg [SD 30·1] vs 189·8 mm Hg [38·5], pblood pressure after intracerebral haemorrhage was substantially higher than premorbid levels (mean increase of 40·7 mm Hg, pblood pressure also increased steeply in the days and weeks before intracerebral haemorrhage (regression pblood pressure reading after primary intracerebral haemorrhage was more likely than after ischaemic stroke to be the highest ever recorded (OR 3·4, 95% CI 2·3–5·2, pblood pressure within 3 h of onset was 50 mm Hg higher, on average, than the maximum premorbid level whereas that after ischaemic stroke was 5·2 mm Hg lower (pblood pressure is substantially raised compared with usual premorbid levels after intracerebral haemorrhage, whereas acute

  9. Comparison of levobunolol and brimonidine in prophylaxis of intraocular pressure (iop|) rise following nd: yag laser capsulotomy

    International Nuclear Information System (INIS)

    Habib, M.; Akram, A

    2015-01-01

    To compare the efficacy of topical 0.5% Levobunolol and 0.2% Brimonidine in preventing intraocular pressure rise after Nd: YAG laser posterior capsulotomy. Study Design: Randomized controlled trial (RCT). Setting and Duration of Study: Ophthalmology Department Combined Military Hospital Multan, from September 2010 to March 2011. Patients and Methods: A total of 82 patients fulfilling the inclusion criteria were selected from out-patient department and randomly divided into two equal groups. Topical 0.5% levobunolol was instilled in group A while 0.2% brimonidine was instilled in group B one hour before and immediately after doing Nd:YAG laser capsulotomy. The intraocular pressure (IOP) was measured using Goldmann applanation tonometer 1, 3 and 24 hours later. Data was analyzed using SPSS version 15.0. Results: There was no statistically significant difference in mean IOP between 0.5% Levobunolol group (Group A) and 0.2% Brimonidine group (Group B) at 1 hour, 3 hours and 24 hours after Nd:YAG laser capsulotomy. The mean intraocular pressure (IOP) one hour after Nd:YAG laser and topical treatment in group A was 16.10 ± 1.60 mmHg while in group B was 15.65 ± 3.01 mmHg (P=0.401). Mean IOP after three hours in group A was 15.80 ± 1.35 mm Hg and in group B was 15.05 ± 2.15 mmHg (p=0.062). Mean IOP after 24 hours in group A was 15.13 ± 2.05 mmHg while in group B was 14.32 ± 1.62 mmHg (p=0.058). Conclusion: Both 0.5% Levobunolol and 0.2% Brimonidine are equally effective in controlling the IOP spike after Nd: YAG laser capsulotomy. Either of these medicines can be used as a prophylaxis to prevent rise in IOP after Nd:YAG laser capsulotomy. (author)

  10. Distribution and air-sea exchange of mercury (Hg in the Yellow Sea

    Directory of Open Access Journals (Sweden)

    Z. J. Ci

    2011-03-01

    Full Text Available The Yellow Sea, surrounded by East China and the Korea Peninsula, is a potentially important receptor for anthropogenic mercury (Hg emissions from East Asia. However, there is little documentation about the distribution and cycle of Hg in this marine system. During the cruise covering the Yellow Sea in July 2010, gaseous elemental mercury (GEM or Hg(0 in the atmosphere, total Hg (THg, reactive Hg (RHg and dissolved gaseous mercury (DGM, largely Hg(0 in the waters were measured aboard the R/V Kexue III. The mean (±SD concentration of GEM over the entire cruise was 2.61 ± 0.50 ng m−3 (range: 1.68 to 4.34 ng m−3, which were generally higher than other open oceans. The spatial distribution of GEM generally reflected a clear gradient with high levels near the coast of East China and low levels in open waters, suggesting the significant atmospheric Hg outflow from East China. The mean concentration of THg in the surface waters was 1.69 ± 0.35 ng l−1 and the RHg accounted for a considerable fraction of THg (RHg: 1.08 ± 0.28 ng l−1, %RHg/THg = 63.9%. The mean concentration of DGM in the surface waters was 63.9 ± 13.7 pg l−1 and always suggested the supersaturation of Hg(0 in the surface waters with respect to Hg(0 in the atmosphere (the degree of saturation: 7.8 ± 2.3 with a range of 3.6–14.0. The mean Hg(0 flux at the air-sea interface was estimated to be 18.3 ± 11.8 ng m−2 h−1 based on a two-layer exchange model. The high wind speed and DGM levels induced the extremely high Hg(0 emission rates. Measurements at three stations showed no clear vertical patterns of DGM, RHg and THg in the water column. Overall, the elevated Hg levels in the Yellow Sea compared with other open oceans suggested that the human activity has influenced the oceanic Hg cycle downwind of East Asia.

  11. Mask pressure effects on the nasal bridge during short-term noninvasive ventilation

    Science.gov (United States)

    Brill, Anne-Kathrin; Pickersgill, Rachel; Moghal, Mohammad; Morrell, Mary J.; Simonds, Anita K.

    2018-01-01

    The aim of this study was to assess the influence of different masks, ventilator settings and body positions on the pressure exerted on the nasal bridge by the mask and subjective comfort during noninvasive ventilation (NIV). We measured the pressure over the nasal bridge in 20 healthy participants receiving NIV via four different NIV masks (three oronasal masks, one nasal mask) at three different ventilator settings and in the seated or supine position. Objective pressure measurements were obtained with an I-Scan pressure-mapping system. Subjective comfort of the mask fit was assessed with a visual analogue scale. The masks exerted mean pressures between 47.6±29 mmHg and 91.9±42.4 mmHg on the nasal bridge. In the supine position, the pressure was lower in all masks (57.1±31.9 mmHg supine, 63.9±37.3 mmHg seated; pmasks, a change of inspiratory positive airway pressure (IPAP) did not influence the objective pressure over the nasal bridge. Subjective discomfort was associated with higher IPAP and positively correlated with the pressure on the skin. Objective measurement of pressure on the skin during mask fitting might be helpful for mask selection. Mask fitting in the supine position should be considered in the clinical routine. PMID:29637077

  12. Determination of Hg and diet identification in otter (Lontra longicaudis) feces

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Josef, Carla [Centro de Energia Nuclear na Agricultura - CENA-USP, Universidade de Sao Paulo, Av. Centenario 303, 13400-970 Piracicaba, Sao Paulo (Brazil)], E-mail: carlajosef@hotmail.com; Ramos Adriano, Leonardo; Franca, Elvis Joacir de; Gustinelli Arantes de Carvalho, Gabriel [Centro de Energia Nuclear na Agricultura - CENA-USP, Universidade de Sao Paulo, Av. Centenario 303, 13400-970 Piracicaba, Sao Paulo (Brazil); Ferreira, Jose Roberto [Centro de Energia Nuclear na Agricultura - CENA-USP, Universidade de Sao Paulo, Av. Centenario 303, 13400-970 Piracicaba, Sao Paulo (Brazil); Polo de Pesquisa e Desenvolvimento Regional do Centro Sul - APTA, Agencia Paulista de Tecnologia dos Agronegocios. Rua Alberto Coral 1500, 13400-000 Piracicaba, Sao Paulo (Brazil)

    2008-04-15

    An analytical procedure for the determination of Hg in otter (Lontra longicaudis) feces was developed, to separate fish scales for the identification of the animal diet. Samples were washed with ultra-pure water and the suspension was sampled and transferred for digestion. The solubilization was performed with nitric-perchloric acid mixture, and detection carried out by the atomic fluorescence spectrometry (AFS). The quality of the analytical procedure was assessed by analyzing in-house standard solutions and certified reference materials. Total Hg concentrations were in the range of 7.6-156 ng g{sup -1} (July 2004), 25.6-277 ng g{sup -1} (January 2005) and 14.6-744 ng g{sup -1} (May 2005) that is approximately the same order of magnitude for all samples collected in two reservoirs at the Tiete River, Brazil. Although Hg concentrations varied with sampling periods and diet, high levels were correlated to the percentage of carnivorous fish scales present in the otter feces. - The importance of otter feces preparation for Hg analysis, focusing the food web.

  13. Determination of Hg and diet identification in otter (Lontra longicaudis) feces

    International Nuclear Information System (INIS)

    Ferreira Josef, Carla; Ramos Adriano, Leonardo; Franca, Elvis Joacir de; Gustinelli Arantes de Carvalho, Gabriel; Ferreira, Jose Roberto

    2008-01-01

    An analytical procedure for the determination of Hg in otter (Lontra longicaudis) feces was developed, to separate fish scales for the identification of the animal diet. Samples were washed with ultra-pure water and the suspension was sampled and transferred for digestion. The solubilization was performed with nitric-perchloric acid mixture, and detection carried out by the atomic fluorescence spectrometry (AFS). The quality of the analytical procedure was assessed by analyzing in-house standard solutions and certified reference materials. Total Hg concentrations were in the range of 7.6-156 ng g -1 (July 2004), 25.6-277 ng g -1 (January 2005) and 14.6-744 ng g -1 (May 2005) that is approximately the same order of magnitude for all samples collected in two reservoirs at the Tiete River, Brazil. Although Hg concentrations varied with sampling periods and diet, high levels were correlated to the percentage of carnivorous fish scales present in the otter feces. - The importance of otter feces preparation for Hg analysis, focusing the food web

  14. EFFECTIVENESS OF LAVENDER AROMATHERAPY AND CLASSICAL MUSIC THERAPY IN LOWERING BLOOD PRESSURE IN PREGNANT WOMEN WITH HYPERTENSION

    Directory of Open Access Journals (Sweden)

    Sri Maisi

    2017-12-01

    Full Text Available Background: Hypertension during pregnancy remains high in Indonesia. It is a major cause of maternal death. Aromatherapy lavender and classical music therapy are considered effective in lowering blood pressure in hypertension. Objective: To examine the effect of lavender aromatherapy and classical music therapy in lowering blood pressure in pregnant women with hypertension. Methods: A quasy experimental study with pretest-posttest control group design. There were 52 pregnant women with the inclusion criteria selected as samples using simple random sampling, divided into lavender aromatherapy group, classical music group, combination of aromatherapy and music group, and control group. Sphygmomanometer was used to measure blood pressure. Mann Whitney and Post Hoc test were used for data analysis. Results: Results showed that four groups have a significant decrease in systolic blood pressure after given intervention with p-value <0.05. The mean decrease of systolic blood pressure among four groups was: lavender group (5.77 mmHg, music group (7.23 mmHg, combination group (9.54 mmHg, and control group (3.67 mmHg; and the mean decrease of diastolic blood pressure was: the lavender group (2.77 mmHg, music group (0.61 mmHg, combination group (8.23 mmHg, and control group (3.42 mmHg. Conclusion: there was a significant effect of lavender aromatherapy and classical music therapy in lowering blood pressure in pregnant women with hypertension. However, the combination of both interventions was more effective than lavender aromatherapy or music therapy alone.

  15. Phase equilibria and thermodynamic functions for Ag–Hg and Cu–Hg binary systems

    International Nuclear Information System (INIS)

    Liu, Yajun; Wang, Guan; Wang, Jiang; Chen, Yang; Long, Zhaohui

    2012-01-01

    Highlights: ► The thermodynamic properties of Ag–Hg and Cu–Hg are explored in order to facilitate dental materials design. ► A self-consistent set of thermodynamic parameters is obtained. ► The experimental information can be well reproduced by the optimized thermodynamic data. - Abstract: In order to facilitate the computational design of new amalgams for novel dental alloys, the phase equilibria, phase diagrams and thermodynamic functions for Ag–Hg and Cu–Hg binary systems are explored in this work, based on the CALPHAD framework and experimental characterizations. The Gibbs free energies of the solution phases as well as the stoichiometric phases are calculated, with the aid of enthalpies of mixing, activities, enthalpies of formation, and phase equilibrium data. The thermodynamic descriptions provided in this work enable the stabilities of each phase at various temperatures and compositions to be well described, which contribute to the establishment of a general database to design novel metallic dental materials.

  16. Phase equilibria and thermodynamic functions for Ag-Hg and Cu-Hg binary systems

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yajun, E-mail: yajunliu@gatech.edu [School of Materials and Energy, Guangdong University of Technology, Guangzhou, Guangdong 510006 (China); Wang, Guan [School of Electromechanical Engineering, Guangdong University of Technology, Guangzhou, Guangdong 510006 (China); Wang, Jiang [School of Materials Science and Engineering, Guilin University of Electronic Technology, Guilin, Guangxi 541004 (China); Chen, Yang [Mining, Metallurgy and Materials Research Department, General Research Institute for Nonferrous Metals, Beijing 100088 (China); Long, Zhaohui [School of Mechanical Engineering, Xiangtan University, Xiangtan, Hunan 411105 (China)

    2012-11-10

    Highlights: Black-Right-Pointing-Pointer The thermodynamic properties of Ag-Hg and Cu-Hg are explored in order to facilitate dental materials design. Black-Right-Pointing-Pointer A self-consistent set of thermodynamic parameters is obtained. Black-Right-Pointing-Pointer The experimental information can be well reproduced by the optimized thermodynamic data. - Abstract: In order to facilitate the computational design of new amalgams for novel dental alloys, the phase equilibria, phase diagrams and thermodynamic functions for Ag-Hg and Cu-Hg binary systems are explored in this work, based on the CALPHAD framework and experimental characterizations. The Gibbs free energies of the solution phases as well as the stoichiometric phases are calculated, with the aid of enthalpies of mixing, activities, enthalpies of formation, and phase equilibrium data. The thermodynamic descriptions provided in this work enable the stabilities of each phase at various temperatures and compositions to be well described, which contribute to the establishment of a general database to design novel metallic dental materials.

  17. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  18. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: the CoCo trial.

    Science.gov (United States)

    Steurer-Stey, Claudia; Zoller, Marco; Chmiel Moshinsky, Corinne; Senn, Oliver; Rosemann, Thomas

    2010-04-14

    Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). Randomised controlled study. 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range 140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg) lead to better self-monitoring compared with the conventional (non-colour-coded) blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation) of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. ClinicalTrials.gov ID NCT01013467.

  19. Changes of intraocular pressure in different trimesters of pregnancy among Syrian refugees in Turkey: A cross-sectional study.

    Science.gov (United States)

    Tolunay, Harun Egemen; Özcan, Sait Coşkun; Şükür, Yavuz Emre; Özarslan Özcan, Deniz; Adıbelli, Fatih Mehmet; Hilali, Neşe Gül

    2016-06-01

    To evaluate the physiologic changes in intraocular pressure associated with pregnancy in healthy Syrian refugee women in Turkey. In this cross-sectional study, intraocular pressures were measured using a Goldmann tonometer in 235 patients in the first, second, and third trimester of pregnancy and puerperium among Syrian refugees in Turkey. Mean intraocular pressures values of the right eye were 15.5±2.5 mmHg, 14.4±1.4 mmHg, 13.9±1.6 and 14.7±1.9 mmHg in the three trimesters and puerperium, respectively. Mean intraocular pressures values of the left eye were 15.3±1.6 mmHg, 14.3±1.4 mmHg, 13.9±1.6 and 15.3±2.2 mmHg in the three trimesters and puerperium, respectively. The mean intraocular pressures values measured from both eyes were significantly higher in first trimester and puerperal period than in the third trimester (p<0.001). Changes in the intraocular pressure in pregnancy are common and temporary. This study shows the baseline changes in the intraocular pressure during pregnancy in healthy women. Therefore, we cannot extrapolate the results to the whole eye. A decrease in intraocular pressures was shown in healthy pregnant women.

  20. Isotopic Hg in an Allende carbon-rich residue

    Science.gov (United States)

    Reed, G. W., Jr.; Jovanovic, S.

    1990-01-01

    A carbon-rich residue from Allende subjected to stepwise heating yielded two isotopically resolvable types of Hg: one with an (Hg-196)/(Hg-202) concentration ratio the same as terrestrial (monitor) Hg; the other enriched in Hg-196 relative to Hg-202 by about 60 percent. Hg with the 202 isotope enriched relative to 196, as is found in bulk Allende, was not observed. Whether the result of mass fractionation or nucleosynthesis, the distinct types of Hg entered different carrier phases and were not thermally mobilized since the accretion of the Allende parent body.

  1. A structural study of the pseudo-binary mercury chalcogenide alloy HgSe sub 0 sub . sub 7 S sub 0 sub . sub 3 at high pressure

    CERN Document Server

    Kozlenko, D P; Hull, S; Knorr, K; Savenko, B N; Shchennikov, V V; Voronin, V I

    2002-01-01

    The structure of the pseudo-binary mercury chalcogenide alloy HgSe sub 0 sub . sub 7 S sub 0 sub . sub 3 has been studied by means of X-ray and neutron powder diffraction at pressure up to 8.5 GPa. A phase transition from the cubic zinc blende structure to the hexagonal cinnabar structure was observed at P approx 1 GPa. The obtained structural parameters were used for the analysis of the geometrical relationship between the zinc blende and the cinnabar phases. The zinc blende-cinnabar phase transition is discussed in the framework of the Landau theory of phase transitions. It was found that the possible order parameter for the structural transformation is the spontaneous strain e sub 4. This assignment agrees with previously observed high pressure behaviour of the elastic constants of other mercury chalcogenides

  2. Efficacy of nutritional recommendations given by registered dietitians compared to other healthcare providers in reducing arterial blood pressure: Systematic review and meta-analysis.

    Science.gov (United States)

    Riegel, Glaube Raquel; Ribeiro, Paula A B; Rodrigues, Marcela Perdomo; Zuchinali, Priccila; Moreira, Leila Beltrami

    2018-04-01

    The multidisciplinary health practitioners can facilitate adherence to treatment of hypertension. Nutritional recommendations delivered by an expert in nutrition might increase the blood pressure control through a better comprehension about how nutrition plays a role on hypertension. To evaluate the effect of nutritional intervention performed by a multidisciplinary team with and without registered dietitians compared to usual care in blood pressure control of hypertensive patients. Systematic review including randomized clinical trials that assessed participants >18 years, both sexes, with blood pressure ≥140/90 mmHg or use of antihypertensive, ≥8 weeks duration and at least one nutritional planned intervention versus usual care. The search was conducted in July 2015 in MEDLINE, EMBASE, BIREME, Web of Science and LILACS without limitation to language. Outcome was defined as deltas of systolic (SBP) and diastolic blood pressure (DBP). Sub-group analysis was conducted according to the presence or not of the registered dietitians in the staff. The analyses were performed in RevMan 5.3 software, using random effects model with heterogeneity assessed by statistical I 2 . From 7280 identified titles, 62 studies were selected for data extraction, and 13 were included in the meta-analysis, with a total of 2050 participants. There was a greater reduction in ΔSBP -2.82 mmHg (95% CI: 4.03 to -1.62) and ΔDBP -1.37 mmHg (95% CI: -2.11 to -0.62) when diet recommendations have been delivered by multi-professional team versus usual care. In stratified analyses only the subgroup of studies with registered dietitians showed statistical significant reduction in blood pressure ΔSBP -3.21 mmHg (95% CI: -4.14 to -2.27); ΔDBP -1.46 mmHg (95% CI: -2.06 to -0.86). There were significant differences between the deltas of blood pressure according to sodium restriction (ΔSBP -3.5 mmHg (95% CI: -4.52 to -2.48), ΔDBP -1.69 mmHg (95% CI: -2.36 to -1, 02)) and

  3. An investigation of mercury sources in the Puyango-Tumbes River: Using stable Hg isotopes to characterize transboundary Hg pollution.

    Science.gov (United States)

    Schudel, Gary; Miserendino, Rebecca Adler; Veiga, Marcello M; Velasquez-López, P Colon; Lees, Peter S J; Winland-Gaetz, Sean; Davée Guimarães, Jean Remy; Bergquist, Bridget A

    2018-07-01

    Mercury (Hg) concentrations and stable isotopes along with other trace metals were examined in environmental samples from Ecuador and Peru's shared Puyango-Tumbes River in order to determine the extent to which artisanal- and small-scale gold mining (ASGM) in Portovelo-Zaruma, Ecuador contributes to Hg pollution in the downstream aquatic ecosystem. Prior studies investigated the relationship between ASGM activities and downstream Hg pollution relying primarily on Hg concentration data. In this study, Hg isotopes revealed an isotopically heavy Hg signature with negligible mass independent fractionation (MIF) in downstream sediments, which was consistent with the signature observed in the ASGM source endmember. This signature was traced as far as ∼120 km downstream of Portovelo-Zaruma, demonstrating that Hg stable isotopes can be used as a tool to fingerprint and trace sources of Hg over vast distances in freshwater environments. The success of Hg isotopes as a source tracer in fresh waters is largely due to the particle-reactive nature of Hg. Furthermore, the magnitude and extent of downstream Hg, lead, copper and zinc contamination coupled with the Hg isotopes suggest that it is unlikely that the smaller artisanal-scale activities, which do not use cyanidation, are responsible for the pollution. More likely it is the scale of ores processed and the cyanide leaching, which can release other metals and enhance Hg transport, used during small-scale gold mining that is responsible. Thus, although artisanal- and small-scale gold mining occur in tandem in Portovelo-Zaruma, a distinction should be made between these two activities. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Electric field gradients in Hg compounds

    DEFF Research Database (Denmark)

    Arcisauskaité, Vaida; Knecht, Stefan; Sauer, Stephan P. A.

    2012-01-01

    &H functional performs best at both 4-component and ZORA levels. We furthermore observe that changes in the largest component of the diagonalised EFG tensor, Vzz, of linear HgCl2 show a slightly stronger dependence than the r-3 scaling upon bond length r(Hg-Cl) alterations. The 4-component/BH&H Vzz value of -9.......26 a.u. for a bent HgCl2 (¿ Cl-Hg-Cl = 120¿) is close to -9.60 a.u. obtained for the linear HgCl2 structure. Thus a point charge model for EFG calculations completely fails in this case. By means of a projection analysis of molecular orbital (MO) contributions to Vzz in terms of the atomic constituents...

  5. The effects of family income on the relationship of various anthropometric parameters with blood pressure in male population of Multan

    International Nuclear Information System (INIS)

    Khan, T.H.; Rana, S.A.; Mahmud, Z.

    2003-01-01

    A randomly selected sample of 497 human males, ageing from 18 to 90 years and representing different ethnic and socio-economic groups of Multan was taken. Income (Rs.), height (cm), weight(kg), BMI (kg m/sup -2), circumferences and blood pres one of the six different income groups i.e., 25000.Mean values plus minus SEM of income, weight, height, BMI, arm, neck, waist, hips and total circumferences, were 13881.6 plus minus 1835.6, 64.0 plus minus 0.5, 171.6 plus minus 2.9, 21.5 plus minus 0.2, 26.5 plus minus 0.1, 36.2 plus minus 0.1, 81.4 plus minus 0.5, 93.0 plus minus 0.4 and 237.2 plus minus 0.9 respectively. Systolic blood pressure (SBP), diastolic blood pressure (DBP), pulse pressure (PP) and mean arterial pressure (MAP) were 122.2 plus minus 0.5, 80.7 plus minus 0.4, 41.5 plus minus 0.5 and 94.5 plus minus 0.4 respectively. All these parameters were also recorded and analysed in different income groups. The prevalence of obesity and hypertension was found to be 3.6% and 11.4% in the total sample. The correlation and regression coefficients between different independent (income, weight, height, BMI, circumferences) and dependent (SBP, DBP, PP and MAP) parameters were calculated and it was observed that there was a strong association between different parameters (P<0.01 or P<0.05). The regression coefficients of BMI with SBP, DBP, PP and MAP were 0.744 mmHg, 0.449 mmHg, 0.296 mmHg and 0.551 per unit of BMI, respectively (P<0.001). The arm, neck, waist, hip and total circumference had regression coefficients with SBP, DBP, and MAP as, arm 0.879, 0.547, 0.667, neck 1.020, 0.660, 0.788, waist 0.244, 0.162, 0.149, hip 0.348, 0.181, 0.238 and total 0.142, 0.855, 0.105 (P<0.01) respectively. It was found that weight and BMI are more important for the prediction of blood pressure whereas all the circumferences had weak association with blood pressure. (author)

  6. Protein changes in Lepidium sativum L. exposed to Hg during soil phytoremediation.

    Science.gov (United States)

    Smolinska, Beata; Szczodrowska, Agnieszka; Leszczynska, Joanna

    2017-08-03

    Some investigations have been carried out in this study to find the best technique of soil reclamation in mercurypolluted soil. In this study, we examined Lepidium sativum L. as a plant useful for Hg phytoextraction. The simultaneous application of compost and thiosulfate was explored as a possible method of enhancing the process of phytoextraction. The results of the investigations of plant protein changes during assisted Hg phytoextraction were also provided. The results of the study show that combined use of compost and thiosulfate significantly increased both the total Hg accumulation and its translocation to aerial plant tissues. Plant protein analysis showed that L. sativum L. has the ability to respond to environmental stress condition by the activation of additional proteins. The additional proteins, like homocysteine methyltransferase, ribulose bisphosphate carboxylases (long and short chains), 14-3-3-like protein, and biosynthesis-related 40S ribosomal protein S15, were activated in plant shoots only in experiments carried out in Hg-polluted soil. There were no protein changes observed in plants exposed to compost and thiosulfate. It suggests that the combined use of compost and thiosulfate decreased Hg toxicity.

  7. Stress modeling of microdiaphragm pressure sensors

    Science.gov (United States)

    Tack, P. C.; Busta, H. H.

    1986-01-01

    A finite element program analysis was used to model the stress distribution of two monocrystalline silicon diaphragm pressure sensors. One configuration consists of an anisotropically backside etched diaphragm into a 250 micron thick, (100) oriented, silicon wafer. The diaphragm and total chip dimensions are given. The device is rigidly clamped on the back to a support substrate. Another configuration consists of a monocrystalline, (100), microdiaphragm which is formed on top of the wafer and whose area is reduced by a factor of 25 over the first configuration. The diaphragm is rigidly clamped to the silicon wafer. The stresses were calculated at a gauge pressure of 300 mm Hg and used to estimate the piezoresistive responses of resistor elements which were placed parallel and perpendicular near the diaphragm edges.

  8. Total dissolved gas, barometric pressure, and water temperature data, lower Columbia River, Oregon and Washington, 1996

    Science.gov (United States)

    Tanner, Dwight Q.; Harrison, Howard E.; McKenzie, Stuart W.

    1996-01-01

    Increased levels of total dissolved gas pressure can cause gas-bubble trauma in fish downstream from dams on the Columbia River. In cooperation with the U.S. Army Corps of Engineers, the U.S. Geological Survey collected data on total dissolved gas pressure, barometric pressure, water temperature, and dissolved oxygen pressure at 11 stations on the lower Columbia River from the John Day forebay (river mile 215.6) to Wauna Mill (river mile 41.9) from March to September 1996. Methods of data collection, review, and processing are described in this report. Summaries of daily minimum, maximum, and mean hourly values are presented for total dissolved gas pressure, barometric pressure, and water temperature. Hourly values for these parameters are presented graphically. Dissolved oxygen data are not presented in this report because the quality-control data show that the data have poor precision and high bias. Suggested changes to monitoring procedures for future studies include (1) improved calibration procedures for total dissolved gas and dissolved oxygen to better define accuracy at elevated levels of supersaturation and (2) equipping dissolved oxygen sensors with stirrers because river velocities at the shoreline monitoring stations probably cannot maintain an adequate flow of water across the membrane surface of the dissolved oxygen sensor.

  9. Comparative study of intraocular pressure (IP in Bangladeshi individuals by contact and non contact technique

    Directory of Open Access Journals (Sweden)

    Sayed Abdul Wadud

    2016-07-01

    Full Text Available Background: Intraocular pressure (IOP is one of the most important parameters in the diagnosis and treatment of glaucoma. Glaucoma has been established as the second leading cause of blindness. The treatment of glaucoma focuses mainly on lowering intraocular pressure (IOP. The target IOP is often set to a level 20% to 30% of IOP reduction, and consequent large IOP reduction beyond 30% or even 40% in cases of advanced glaucoma The different methods of tonometery are: Goldman Applanation tonometery, Noncontact (air-puff tonometery, Perkins tonometery, Tonopen tonometery, Transpalpebral tonometery.Objective: To determine the frequency of accuracy of intraocular pressure (IOP measured by non-contact (air puff tonometer compared with Goldmann applanation tonometer.Methods: This was a non-interventional, cross sectional study conducted at a tertiary care centre of Dhaka, Bangladesh. consecutive subjects attending the BSMMU eye OPD were included in the study. IOP was measured by non-contact (air puff tonometer and a slit lamp mounted GAT in all the subjects. The study samples were selected by convenience sampling who presented for check-up in the Eye Department of community ophthalmology, Bangabandhu Sheikh Mujib Medical University, Dhaka. Bangladesh. Results:A total of 120 eyes in 60 patients were studied. The mean age of the patients was 41.60 year. study population consisted of 24 (40 % men and 36 (60 % women. The mean intraocular pressure was 13.52 &13.72 mmHg for GAT, and 16.64 & 17.44 mmHg for Air puff respectively. The range of measurements by GAT was from 10 to 23 mmHg and by Air puff was 12 to 28mmHg. The difference between IOP measured by two instruments were statistically significant (p=0.000.Conclusion: Airpuff tonometer is quick, a non-contact method to measure intraocular pressure and is useful for screening purposes and postoperative case but the measurements should be confirmed with Goldmann applanation tonometer for accurate labelling

  10. Isotopic Hg in an Allende carbon-rich residue

    International Nuclear Information System (INIS)

    Reed, G.W. Jr.; Jovanovic, S.

    1990-01-01

    A carbon-rich residue from Allende subjected to stepwise heating yielded two isotopically resolvable types of Hg: one with an (Hg-196)/(Hg-202) concentration ratio the same as terrestrial (monitor) Hg; the other enriched in Hg-196 relative to Hg-202 by about 60 percent. Hg with the 202 isotope enriched relative to 196, as is found in bulk Allende, was not observed. Whether the result of mass fractionation or nucleosynthesis, the distinct types of Hg entered different carrier phases and were not thermally mobilized since the accretion of the Allende parent body. 9 refs

  11. 40 CFR 60.4142 - Hg allowance allocations.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Hg allowance allocations. 60.4142... Coal-Fired Electric Steam Generating Units Hg Allowance Allocations § 60.4142 Hg allowance allocations. (a)(1) The baseline heat input (in MMBtu) used with respect to Hg allowance allocations under...

  12. NAA, GC(EC) and SRXRF study of Hg species in head hair of mothers and their newborn infants

    International Nuclear Information System (INIS)

    Feng Weiyue; Qian Qinfang; Zhang Peiqun; Chai Zhifang

    1997-01-01

    Twenty-seven pairs of head from mothers and their new-born infants were collected at the time of delivery in a hospital in Beijing. The total mercury content in the hair samples was determined by INAA. The correlation between mercury content in hair of mothers and their new-born infants has been investigated. In addition, the change of Hg content in pregnant women's hair during their pregnancy was also studied by INAA and SRXRF. The results indicate a significant positive correlation between the mercury content in maternal and infant head hairs (r = +0.862, p < 0.001). The average content of Hg in infant and maternal hairs was (0.66 +- 0.31) μg/g and (0.59 +- 0.25) μg/g, respectively. The infant level exceeded the maternal by 12%. The Hg content in maternal head hair gradually reduced during pregnancy. Further, the methylmercury (Me-Hg) content in 3 maternal hair samples was analyzed by GC(EC). The Me-Hg was in accordance with the total mercury content. Thus a conclusion can be drawn that damage to the infant from Hg occurred in the early stages of pregnancy

  13. Effects of an isocaloric healthy Nordic diet on ambulatory blood pressure in metabolic syndrome

    DEFF Research Database (Denmark)

    Brader, Lea Johanne; Uusitupa, M; Dragsted, Lars Ove

    2014-01-01

    Background/objectives:Dietary pattern is central in the prevention of hypertension and blood pressure (BP)-related diseases. A diet based on healthy Nordic foods may have a favourable impact on BP. The objective was to clarify whether a Nordic alternative for a healthy food pattern would have...... beneficial effects on ambulatory BP in subjects with metabolic syndrome (MetS).Subjects/methods:In total, 37 subjects were randomized to either a healthy Nordic diet or a control diet. A healthy Nordic diet embraced whole grains, rapeseed oil, berries, fruits, vegetables, fish, nuts and low-fat dairy...... weeks of intervention.Results:After 12 weeks, ambulatory diastolic BP (-4.4 mm Hg; P=0.001) and mean arterial pressure (-4.2 mm Hg; P=0.006) were lowered by the healthy Nordic diet compared with the control diet, whereas changes in ambulatory systolic BP did not differ significantly between diets (-3...

  14. Blood pressure and lipid profiles in adolescents with hypertensive parents

    Directory of Open Access Journals (Sweden)

    Julia Fitriany

    2016-11-01

    Full Text Available Background Adolescent hypertension is a significant health problem of increasing prevalence and causes high morbidity and mortality. It is found primarily in young males, with a familial history of hypertension and/or cardiovascular disease. Examination of lipid profiles has been used to detect the risk of hypertension in adolescents. Objective To compare blood pressure and lipid profiles in adolescents with and without a parental history of hypertension. Methods This cross-sectional study was conducted from January to February 2012 on students from a senior high school in the Toba Samosir District, North Sumatera. Sixty-eight adolescents were included, aged 15 to 18 years. Group I comprised 34 adolescents with hypertensive parents, and group II comprised 34 adolescents with normotensive parents. Subjects were selected based on questionnaires. Subjects’ blood pressures were measured at rest. Three measurements were made in intervals of 10-15 minutes, then averaged for both systolic and diastolic blood pressures. Lipid profiles were measured using the CardioCheck cholesterol test after subjects had fasted for 12 hours. Results The median systolic blood pressures (SBP in groups I and II were 110 mmHg (range 93.3-123.3 and 106.7 mmHg (range 96.7-123.3, respectively, (P=0.584. The median diastolic blood pressures (DBP were 73.3 mmHg (range 66.7-83.3 and 71.7 mmHg (range 63.3-80.0, respectively, (P=0.953. Total cholesterol and low-density lipoprotein cholesterol (LDL-C levels in group I were significantly higher than those levels in group II [median total cholesterol: 162.0 (range 158-170 vs. 159.0 (range 150-170, respectively; (P=0.001; and mean LDL-C: 103.5 (SD 3.72 vs. 99.1 (SD 4.63, respectively; (P=0.001. Multivariate analysis revealed a correlation of moderate strength between parental history of hypertension and increased LDL-C (P<0.001 in adolescents. Conclusion Adolescents with and without familial history of hypertension have no

  15. Streamwater fluxes of total mercury and methylmercury into and out of Lake Champlain

    International Nuclear Information System (INIS)

    Shanley, James B.; Chalmers, Ann T.

    2012-01-01

    From 2000 to 2004, we sampled for total mercury (THg) and methylmercury (MeHg) in inlet streams to Lake Champlain, targeting high flow periods to capture increases in THg and MeHg concentrations with increasing flow. We used these data to model stream THg and MeHg fluxes for Water Years 2001 through 2009. In this mountainous forested basin with a high watershed-to-lake area ratio of 18, fluvial export from the terrestrial watershed was the dominant source of Hg to the lake. Unfiltered THg and MeHg fluxes were dominated by the particulate fraction; about 40% of stream THg was in the filtered ( −2 yr −1 , or about 13% of atmospheric Hg wet and dry deposition to the basin. THg export from the lake represented only about 3% of atmospheric Hg input to the basin. - Highlights: ► We monitored total mercury and methylmercury in major tributaries to Lake Champlain. ► Mercury and methylmercury export was primarily as particulates during high flow. ► Only 13% of atmospheric total mercury input reached the lake via streams. ► Only 3% of atmospheric total mercury input reached the lake outlet. - Eighty-seven percent of total mercury deposition to the Lake Champlain basin is retained in the terrestrial basin; stream export of total and methylmercury to the lake is primarily in the particulate phase.

  16. Revisiting the association of blood pressure with mortality in oldest old people in China: community based, longitudinal prospective study

    Science.gov (United States)

    Lv, Yue-Bin; Gao, Xiang; Yin, Zhao-Xue; Chen, Hua-Shuai; Luo, Jie-Si; Brasher, Melanie Sereny; Kraus, Virginia Byers; Li, Tian-Tian; Zeng, Yi

    2018-01-01

    Abstract Objective To examine the associations of blood pressure with all cause mortality and cause specific mortality at three years among oldest old people in China. Design Community based, longitudinal prospective study. Setting 2011 and 2014 waves of the Chinese Longitudinal Healthy Longevity Survey, conducted in 22 Chinese provinces. Participants 4658 oldest old individuals (mean age 92.1 years). Main outcome measures All cause mortality and cause specific mortality assessed at three year follow-up. Results 1997 deaths were recorded at three year follow-up. U shaped associations of mortality with systolic blood pressure, mean arterial pressure, and pulse pressure were identified; values of 143.5 mm Hg, 101 mm Hg, and 66 mm Hg conferred the minimum mortality risk, respectively. After adjustment for covariates, the U shaped association remained only for systolic blood pressure (minimum mortality risk at 129 mm Hg). Compared with a systolic blood pressure value of 129 mm Hg, risk of all cause mortality decreased for values lower than 107 mm Hg (from 1.47 (95% confidence interval 1.01 to 2.17) to 1.08 (1.01 to 1.17)), and increased for values greater than 154 mm Hg (from 1.08 (1.01 to 1.17) to 1.27 (1.02 to 1.58)). In the cause specific analysis, compared with a middle range of systolic blood pressure (107-154 mm Hg), higher values (>154 mm Hg) were associated with a higher risk of cardiovascular mortality (adjusted hazard ratio 1.51 (95% confidence interval 1.12 to 2.02)); lower values (blood pressure and all cause mortality at three years among oldest old people in China. This association could be explained by the finding that higher systolic blood pressure predicted a higher risk of death from cardiovascular disease, and that lower systolic blood pressure predicted a higher risk of death from non-cardiovascular causes. These results emphasise the importance of revisiting blood pressure management or establishing specific guidelines for management among oldest

  17. Selective Hg(II) adsorption from aqueous solutions of Hg(II) and Pb(II) by hydrolyzed acrylamide-grafted PET films.

    Science.gov (United States)

    Rahman, Nazia; Sato, Nobuhiro; Sugiyama, Masaaki; Hidaka, Yoshiki; Okabe, Hirotaka; Hara, Kazuhiro

    2014-01-01

    Selective Hg(II) adsorption from aqueous solutions of Hg(II) and Pb(II) using hydrolyzed acrylamide (AAm)-grafted polyethylene terephthalate (PET) films was examined to explore the potential reuse of waste PET materials. Selective recovery of Hg(II) from a mixture of soft acids with similar structure, such as Hg(II) and Pb(II), is important to allow the reuse of recovered Hg(II). An adsorbent for selective Hg(II) adsorption was prepared by γ-ray-induced grafting of AAm onto PET films followed by partial hydrolysis through KOH treatment. The adsorption capacity of the AAm-grafted PET films for Hg(II) ions increased from 15 to 70 mg/g after partial hydrolysis because of the reduction of hydrogen bonding between -CONH2 groups and the corresponding improved access of metal ions to the amide groups. The prepared adsorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The absorbent film showed high selectivity for the adsorption of Hg(II) over Pb(II) throughout the entire initial metal concentration range (100-500 mg/L) and pH range (2.2-5.6) studied. The high selectivity is attributed to the ability of Hg(II) ions to form covalent bonds with the amide groups. The calculated selectivity coefficient for the adsorbent binding Hg(II) over Pb(II) was 19.2 at pH 4.5 with an initial metal concentration of 100 mg/L. Selective Hg(II) adsorption equilibrium data followed the Langmuir model and kinetic data were well fitted by a pseudo-second-order equation. The adsorbed Hg(II) and Pb(II) ions were effectively desorbed from the adsorbent film by acid treatment, and the regenerated film showed no marked loss of adsorption capacity upon reuse for selective Hg(II) adsorption.

  18. Effects of blood pressure reduction in mild hypertension: a systematic review and meta-analysis.

    Science.gov (United States)

    Sundström, Johan; Arima, Hisatomi; Jackson, Rod; Turnbull, Fiona; Rahimi, Kazem; Chalmers, John; Woodward, Mark; Neal, Bruce

    2015-02-03

    Effects of blood pressure reduction in persons with grade 1 hypertension are unclear. To investigate whether pharmacologic blood pressure reduction prevents cardiovascular events and deaths in persons with grade 1 hypertension. Trials included in the BPLTTC (Blood Pressure Lowering Treatment Trialists' Collaboration) and trials identified from a previous review and electronic database searches. Patients without cardiovascular disease with blood pressures in the grade 1 hypertension range (140 to 159/90 to 99 mm Hg) who were randomly assigned to an active (antihypertensive drug or more intensive regimen) or control (placebo or less intensive regimen) blood pressure-lowering regimen. Individual-patient data from BPLTTC trials and aggregate data from other trials were extracted. Risk of bias was assessed for all trials. Individual-patient data involved 10 comparisons from trials where most patients had diabetes, and aggregate data involved 3 comparisons from trials of patients without diabetes. The average blood pressure reduction was about 3.6/2.4 mm Hg. Over 5 years, odds ratios were 0.86 (95% CI, 0.74 to 1.01) for total cardiovascular events, 0.72 (CI, 0.55 to 0.94) for strokes, 0.91 (CI, 0.74 to 1.12) for coronary events, 0.80 (CI, 0.57 to 1.12) for heart failure, 0.75 (CI, 0.57 to 0.98) for cardiovascular deaths, and 0.78 (CI, 0.67 to 0.92) for total deaths. Results were similar in secondary analyses. Withdrawal from treatment due to adverse effects was more common in the active groups. Blood pressure reductions and numbers of events were small. Blood pressure-lowering therapy is likely to prevent stroke and death in patients with uncomplicated grade 1 hypertension. Swedish Heart-Lung Foundation, Swedish Research Council, Australian Research Council, and National Health and Medical Research Council of Australia.

  19. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  20. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2012-02-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.

  1. Is it possible to shorten ambulatory blood pressure monitoring?

    Science.gov (United States)

    Wolak, Talya; Wilk, Lior; Paran, Esther; Wolak, Arik; Gutmacher, Bella; Shleyfer, Elena; Friger, Michael

    2013-08-01

    The aim of this investigation was to find a time segment in which average blood pressure (BP) has the best correlation with 24-hour BP control. A total of 240 patients with full ambulatory BP monitoring (ABPM) were included; 120 had controlled BP (systolic BP [SBP] ≤135 mm Hg and diastolic BP [DBP] ≤85 mm Hg) and 120 had uncontrolled BP (SBP >135 mm Hg and/or DBP >85 mm Hg). Each ABPM was divided into 6- and 8-hour segments. Evaluation for correlation between mean BP for each time segment and 24-hour BP control was performed using receiver operating characteristic curve analysis and Youden's index for threshold with the best sensitivity and specificity. The mean BP in the following segments showed the highest area under the curve (AUC) compared with average controlled 24-hour BP: SBP 2 am to 8 am (AUC, 0.918; threshold value of 133.5 mm Hg, sensitivity-0.752 and specificity-0.904); SBP 2 pm to 10 pm (AUC, 0.911; threshold value of 138.5 mm Hg, sensitivity-0.803 and specificity-0.878); and SBP 6 am to 2 pm (AUC, 0.903; threshold value of 140.5 mm Hg, sensitivity-0.778 and specificity-0.888). The time segment 2 pm to 10 pm was shown to have good correlation with 24-hour BP control (AUC >0.9; sensitivity and specificity >80%). This time segment might replace full ABPM as a screening measure for BP control or as abbreviated ABPM for patients with difficulty in performing full ABPM. © 2013 Wiley Periodicals, Inc.

  2. Toe Pressures are Superior to Duplex Parameters in Predicting Wound Healing following Toe and Foot Amputations.

    Science.gov (United States)

    Stone, Patrick A; Glomski, Alexis; Thompson, Stephanie N; Adams, Elliott

    2018-01-01

    No criteria, including preamputation vascular diagnostic thresholds, have been established to reliably predict healing versus nonhealing following minor lower extremity amputations. Thus, the goal of our study was to identify clinical factors, including noninvasive vascular laboratory measures, associated with wound healing following toe, forefoot, and midfoot amputations. We retrospectively examined records of patients receiving elective toe, forefoot, or midfoot amputation at our institution over a 5-year span (2010-2015). A total of 333 amputations received noninvasive vascular assessment of the lower extremity preamputation and follow-up at 90 days postamputation. Multivariate binomial logistic regression was used to identify variables predicting wound healing as defined as the absence of reamputation due to wound breakdown. Wound healing occurred in 81% of amputations. A total of 23 (7%) patients required revisions of the foot while 39 (12%) patients required major amputations by 90 days. Chi-squared analysis found that toe pressure at or above the value of 47 mm Hg (P = 0.04), bi/triphasic anterior tibial (P = 0.01), and posterior tibial artery (P = 0.01) waveforms were associated with wound healing. When these diagnostic parameters were examined in the presence of confounders (increasing age, chronic kidney disease, and concomitant revascularization), only toe pressure ≥ 47 mm Hg predicted amputation site healing (odds ratio: 3.1 [95% CI: 1.0-9.4], P = 0.04). Preamputation toe pressures of 47 mm Hg and above are associated with wound healing. No other noninvasive vascular studies predicted wound healing in the presence of confounders. Thus, toe pressures may assist in clinical decision-making and should be routinely obtained preamputation. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Effect of body temperature on peripheral venous pressure measurements and its agreement with central venous pressure in neurosurgical patients.

    Science.gov (United States)

    Sahin, Altan; Salman, M Alper; Salman, A Ebru; Aypar, Ulka

    2005-04-01

    Previous studies suggest a correlation of central venous pressure (CVP) with peripheral venous pressure (PVP) in different clinical settings. The effect of body temperature on PVP and its agreement with CVP in patients under general anesthesia are investigated in this study. Fifteen American Society of Anesthesiologists I-II patients undergoing elective craniotomy were included in the study. CVP, PVP, and core (Tc) and peripheral (Tp) temperatures were monitored throughout the study. A total of 950 simultaneous measurements of CVP, PVP, Tc, and Tp from 15 subjects were recorded at 5-minute intervals. The measurements were divided into low- and high-Tc and -Tp groups by medians as cutoff points. Bland-Altman assessment for agreement was used for CVP and PVP in all groups. PVP measurements were within range of +/-2 mm Hg of CVP values in 94% of the measurements. Considering all measurements, mean bias was 0.064 mm Hg (95% confidence interval -0.018-0.146). Corrected bias for repeated measurements was 0.173 +/- 3.567 mm Hg (mean +/- SD(corrected)). All of the measurements were within mean +/- 2 SD of bias, which means that PVP and CVP are interchangeable in our setting. As all the measurements were within 1 SD of bias when Tc was > or = 35.8 degrees C, even a better agreement of PVP and CVP was evident. The effect of peripheral hypothermia was not as prominent as core hypothermia. PVP measurement may be a noninvasive alternative for estimating CVP. Body temperature affects the agreement of CVP and PVP, which deteriorates at lower temperatures.

  4. Worldwide trends in blood pressure from 1975 to 2015

    DEFF Research Database (Denmark)

    Linneberg, Allan René; Sørensen, Thorkild I.A.

    2017-01-01

    BACKGROUND: Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic blood...... pressure of 140 mm Hg or higher or diastolic blood pressure of 90 mm Hg or higher. METHODS: For this analysis, we pooled national, subnational, or community population-based studies that had measured blood pressure in adults aged 18 years and older. We used a Bayesian hierarchical model to estimate trends...... from 1975 to 2015 in mean systolic and mean diastolic blood pressure, and the prevalence of raised blood pressure for 200 countries. We calculated the contributions of changes in prevalence versus population growth and ageing to the increase in the number of adults with raised blood pressure. FINDINGS...

  5. Reduced injection pressures using a compressed air injection technique (CAIT): an in vitro study.

    Science.gov (United States)

    Tsui, Ban C H; Knezevich, Mark P; Pillay, Jennifer J

    2008-01-01

    High injection pressures have been associated with intraneural injection and persistent neurological injury in animals. Our objective was to test whether a reported simple compressed air injection technique (CAIT) would limit the generation of injection pressures to below a suggested 1,034 mm Hg limit in an in vitro model. After ethics board approval, 30 consenting anesthesiologists injected saline into a semiclosed system. Injection pressures using 30 mL syringes connected to a 22 gauge needle and containing 20 mL of saline were measured for 60 seconds using: (1) a typical "syringe feel" method, and (2) CAIT, thereby drawing 10 mL of air above the saline and compressing this to 5 mL prior to and during injections. All anesthesiologists performed the syringe feel method before introduction and demonstration of CAIT. Using CAIT, no anesthesiologist generated pressures above 1,034 mm Hg, while 29 of 30 produced pressures above this limit at some time using the syringe feel method. The mean pressure using CAIT was lower (636 +/- 71 vs. 1378 +/- 194 mm Hg, P = .025), and the syringe feel method resulted in higher peak pressures (1,875 +/- 206 vs. 715 +/- 104 mm Hg, P = .000). This study demonstrated that CAIT can effectively keep injection pressures under 1,034 mm Hg in this in vitro model. Animal and clinical studies will be needed to determine whether CAIT will allow objective, real-time pressure monitoring. If high pressure injections are proven to contribute to nerve injury in humans, this technique may have the potential to improve the safety of peripheral nerve blocks.

  6. The 24- hour pattern of intraocular pressure in suspected glaucoma patients

    Directory of Open Access Journals (Sweden)

    Shan-Shan Li

    2018-05-01

    Full Text Available AIM: To analyze the value of 24-hour intraocular pressure(IOPmonitoring in suspected glaucoma patients.METHODS: Totally 48 suspected glaucoma(96 eyeswere selected for 24-hour IOP monitoring by using Accupen tonometer(24-3000and non-contact tonometer(NCT, CT-80Afrom 9:30 to 7:30 next day(once in 2h. During 07:30 to 21:30, patients were measured in sitting position, while during 23:30 to 05:30 in both sitting and supine position.RESULTS: A morning peak of IOP was shown at 7:30 in traditional position by using two measures with 22.05±3.608mmHg of NCT and 19.79±4.147mmHg of Accupen tonometer. The peak IOP in habitual position appeared in 5:30 with 21.64±4.814mmHg. The lowest IOP occurred in both position at 21:30 with 15.73±3.649mmHg. Both positions showed IOP trend of going up at night and then declining in the morning. CONCLUSION: The peak IOP in suspected glaucoma occurs mostly at early morning. Supine IOP of sleeping time is higher than that of sitting position.

  7. Oxidative stress in MeHg-induced neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Marcelo, E-mail: farina@ccb.ufsc.br [Departamento de Bioquimica, Centro de Ciencias Biologicas, Universidade Federal de Santa Catarina, Florianopolis, SC (Brazil); Aschner, Michael [Department of Pediatrics, Vanderbilt University Medical Center, Nashville, TN (United States); Department of Pharmacology, Vanderbilt University Medical Center, Nashville, TN (United States); Rocha, Joao B.T., E-mail: jbtrocha@yahoo.com.br [Departamento de Quimica, Centro de Ciencias Naturais e Exatas, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil)

    2011-11-15

    Methylmercury (MeHg) is an environmental toxicant that leads to long-lasting neurological and developmental deficits in animals and humans. Although the molecular mechanisms mediating MeHg-induced neurotoxicity are not completely understood, several lines of evidence indicate that oxidative stress represents a critical event related to the neurotoxic effects elicited by this toxicant. The objective of this review is to summarize and discuss data from experimental and epidemiological studies that have been important in clarifying the molecular events which mediate MeHg-induced oxidative damage and, consequently, toxicity. Although unanswered questions remain, the electrophilic properties of MeHg and its ability to oxidize thiols have been reported to play decisive roles to the oxidative consequences observed after MeHg exposure. However, a close examination of the relationship between low levels of MeHg necessary to induce oxidative stress and the high amounts of sulfhydryl-containing antioxidants in mammalian cells (e.g., glutathione) have led to the hypothesis that nucleophilic groups with extremely high affinities for MeHg (e.g., selenols) might represent primary targets in MeHg-induced oxidative stress. Indeed, the inhibition of antioxidant selenoproteins during MeHg poisoning in experimental animals has corroborated this hypothesis. The levels of different reactive species (superoxide anion, hydrogen peroxide and nitric oxide) have been reported to be increased in MeHg-exposed systems, and the mechanisms concerning these increments seem to involve a complex sequence of cascading molecular events, such as mitochondrial dysfunction, excitotoxicity, intracellular calcium dyshomeostasis and decreased antioxidant capacity. This review also discusses potential therapeutic strategies to counteract MeHg-induced toxicity and oxidative stress, emphasizing the use of organic selenocompounds, which generally present higher affinity for MeHg when compared to the classically

  8. Enhanced Hg{sup 2+} removal and Hg{sup 0} re-emission control from wet fuel gas desulfurization liquors with additives

    Energy Technology Data Exchange (ETDEWEB)

    Tingmei Tang; Jiang Xu; Rongjie Lu; Jingjing Wo; Xinhua Xu [Zhejiang University, Hangzhou (China). Department of Environmental Engineering

    2010-12-15

    Secondary atmospheric pollutions may result from wet flue gas desulfurization (FGD) systems caused by the reduction of Hg{sup 2+} to Hg{sup 0}. The present study employed three agents: Na{sub 2}S, 2,4,6-trimercaptotiazine, trisodium salt nonahydrate (TMT) and sodium dithiocarbamate (DTCR) to precipitate aqueous Hg{sup 2+} in simulated desulfurization solutions. The effects of the precipitator's dosing quantity, the initial pH value, the reaction temperature, the concentrations of Cl{sup -} and other metal ions (e.g. Cu{sup 2+} and Pb{sup 2+}) on Hg{sup 2+} removal were studied. A linear relationship was observed between Hg{sup 2+} removal efficiency and the increasing precipitator's doses along with initial pH. The addition of chloride and metal ions impaired the Hg{sup 2+} removal from solutions due to the complexation of Cl{sup -} and Hg{sup 2+} as well as the chelating competition between Hg{sup 2+} and other metal ions. Based on a comprehensive comparison of the treatment effects, DTCR was found to be the most effective precipitating agent. Moreover, all the precipitating agents were potent enough to inhibit Hg{sup 2+} reduction as well as Hg{sup 0} re-emission from FGD liquors. More than 90% Hg{sup 2+} was captured by precipitating agents while Hg{sup 2+} reduction efficiency decreased from 54% to just less than 3%. The additives could efficiently control the secondary Hg{sup 0} pollution from FGD liquors. 21 refs., 6 figs.

  9. Mercury in stream water at five Czech catchments across a Hg and S deposition gradient

    Science.gov (United States)

    Navrátil, Tomáš; Shanley, James B.; Rohovec, Jan; Oulehle, Filip; Krám, Pavel; Matoušková, Šárka; Tesař, Miroslav; Hojdová, Maria

    2015-01-01

    The Czech Republic was heavily industrialized in the second half of the 20th century but the associated emissions of Hg and S from coal burning were significantly reduced since the 1990s. We studied dissolved (filtered) stream water mercury (Hg) and dissolved organic carbon (DOC) concentrations at five catchments with contrasting Hg and S deposition histories in the Bohemian part of the Czech Republic. The median filtered Hg concentrations of stream water samples collected in hydrological years 2012 and 2013 from the five sites varied by an order of magnitude from 1.3 to 18.0 ng L− 1. The Hg concentrations at individual catchments were strongly correlated with DOC concentrations r from 0.64 to 0.93 and with discharge r from 0.48 to 0.75. Annual export fluxes of filtered Hg from individual catchments ranged from 0.11 to 13.3 μg m− 2 yr− 1 and were highest at sites with the highest DOC export fluxes. However, the amount of Hg exported per unit DOC varied widely; the mean Hg/DOC ratio in stream water at the individual sites ranged from 0.28 to 0.90 ng mg− 1. The highest stream Hg/DOC ratios occurred at sites Pluhův Bor and Jezeří which both are in the heavily polluted Black Triangle area. Stream Hg/DOC was inversely related to mineral and total soil pool Hg/C across the five sites. We explain this pattern by greater soil Hg retention due to inhibition of soil organic matter decomposition at the sites with low stream Hg/DOC and/or by precipitation of a metacinnabar (HgS) phase. Thus mobilization of Hg into streams from forest soils likely depends on combined effects of organic matter decomposition dynamics and HgS-like phase precipitation, which were both affected by Hg and S deposition histories.

  10. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  11. In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring.

    Science.gov (United States)

    Seidlerová, Jitka; Gelžinský, Julius; Mateřánková, Markéta; Ceral, Jiří; König, Petr; Filipovský, Jan

    2018-03-22

    Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.

  12. Models of brachial to finger pulse wave distortion and pressure decrement.

    Science.gov (United States)

    Gizdulich, P; Prentza, A; Wesseling, K H

    1997-03-01

    To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.

  13. Validation of the BPUMP BF1112 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Chen, Qi; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2017-04-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure (BP) monitor BPUMP BF1112 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010 (ESH-IP2010). Systolic and diastolic BPs were sequentially measured in 33 adult Chinese (13 women, mean age 46.7 years) using a mercury sphygmomanometer (two observers) and the BF1112 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The BPUMP BF1112 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 85/99, 96/99, and 97/99, respectively, for systolic BP, and 83/99, 97/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. A total of 31 and 30 participants for systolic and diastolic BP, respectively, had at least two of the three device-observer differences within 5 mmHg (required≥24mmHg). No participant for systolic or diastolic BP had all the three device-observer comparisons greater than 5 mmHg. The BPUMP BP monitor BF1112 has passed the requirements of the ESH-IP2010, and hence can be recommended for home use in adults.

  14. Exploring the relationship of peripheral total bilirubin, red blood cell, and hemoglobin with blood pressure during childhood and adolescence.

    Science.gov (United States)

    Chen, Xiao-Tian; Yang, Song; Yang, Ya-Ming; Zhao, Hai-Long; Chen, Yan-Chun; Zhao, Xiang-Hai; Wen, Jin-Bo; Tian, Yuan-Rui; Yan, Wei-Li; Shen, Chong

    2017-11-04

    Total bilirubin is beneficial for protecting cardiovascular diseases in adults. The authors aimed to investigate the association of total bilirubin, red blood cell, and hemoglobin levels with the prevalence of high blood pressure in children and adolescents. A total of 3776 students (aged from 6 to 16 years old) were examined using cluster sampling. Pre-high blood pressure and high blood pressure were respectively defined as the point of 90th and 95th percentiles based on the Fourth Report on the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents. Both systolic and diastolic blood pressure were standardized into z-scores. Peripheral total bilirubin, red blood cell and hemoglobin levels were significantly correlated with age, and also varied with gender. Peripheral total bilirubin was negatively correlated with systolic blood pressure in 6- and 9-year-old boys, whilst positively correlated with diastolic blood pressure in the 12-year-old boys and 13- to 15-year-old girls (p0.05). Total bilirubin could be weakly correlated with both systolic and diastolic blood pressure, as correlations varied with age and gender in children and adolescents; in turn, the increased levels of red blood cell and hemoglobin are proposed to be positively associated with the prevalence of high blood pressure. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  15. Variability of hydrostatic hepatic vein and ascitic fluid pressure, and of plasma and ascitic fluid colloid osmotic pressure in patients with liver cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl

    1980-01-01

    The variability of hydrostatic hepatic vein and ascitic fluid pressures and of plasma and ascitic fluid colloid osmotic (oncotic) pressures was assessed during hepatic venous catheterization by repeated measurements on different days and at different locations in patients with cirrhosis...... of the liver. Furthermore, calculation of oncotic pressure from protein determinations was compared to the directly measured value of plasma and ascitic fluid samples. Repeated measurements of hydrostatic pressure in the same hepatic vein within 15 min showed a standard deviation (SD) below 1 mm......Hg. The variation in hydrostatic hepatic vein pressures, pressure differences and ascitic fluid pressures (when measured at different locations within the liver and peritoneal space during a single examination) was 1.5, 1.0 and 1.0 mmHg (SD), respectively. When measured on different days, the variation...

  16. Manila clams from Hg polluted sediments of Marano and Grado lagoons (Italy) harbor detoxifying Hg resistant bacteria in soft tissues

    International Nuclear Information System (INIS)

    Baldi, Franco; Gallo, Michele; Marchetto, Davide; Faleri, Claudia; Maida, Isabel; Fani, Renato

    2013-01-01

    A mechanism of mercury detoxification has been suggested by a previous study on Hg bioaccumulation in Manila clams (Ruditapes philippinarum) in the polluted Marano and Grado lagoons and in this study we demonstrate that this event could be partly related to the detoxifying activities of Hg-resistant bacteria (MRB) harbored in clam soft tissues. Therefore, natural clams were collected in six stations during two different periods (winter and spring) from Marano and Grado Lagoons. Siphons, gills and hepatopancreas from acclimatized clams were sterile dissected to isolate MRB. These anatomical parts were glass homogenized or used for whole, and they were lying on a solid medium containing 5 mg l −1 HgCl 2 and incubated at 30 °C. A total of fourteen bacterial strains were isolated and were identified by 16S rDNA sequencing and analysis, revealing that strains were representative of eight bacterial genera, four of which were Gram-positive (Enterococcus, Bacillus, Jeotgalicoccus and Staphylococcus) and other four were Gram-negative (Stenotrophomonas, Vibrio, Raoultella and Enterobacter). Plasmids and merA genes were found and their sequences determined. Fluorescence in situ hybridization (FISH) technique shows the presence of Firmicutes, Actinobacteria and Gammaproteobacteria by using different molecular probes in siphon and gills. Bacterial clumps inside clam flesh were observed and even a Gram-negative endosymbiont was disclosed by transmission electronic microscope inside clam cells. Bacteria harbored in cavities of soft tissue have mercury detoxifying activity. This feature was confirmed by the determination of mercuric reductase in glass-homogenized siphons and gills. -- Highlights: ► We isolated Gram-positive and Gram-negative Hg resistant strains from soft tissues of Ruditapes philippinarum. ► We identify 14 mercury resistant strains by 16S rRNA gene sequences. ► Bacteria in siphon and gill tissues of clams were observed by TEM and identified with

  17. Manila clams from Hg polluted sediments of Marano and Grado lagoons (Italy) harbor detoxifying Hg resistant bacteria in soft tissues

    Energy Technology Data Exchange (ETDEWEB)

    Baldi, Franco [Dipartimento di Scienze Molecolari e Nanosistemi, Cà Foscari University of Venice, Dorsoduro 2137, 30123 Venice (Italy); Gallo, Michele; Marchetto, Davide [Dipartimento di Scienze Molecolari e Nanosistemi, Cà Foscari University of Venice, Dorsoduro 2137, 30123 Venice (Italy); Faleri, Claudia [Department of Environmental Science ‘G. Sarfatti’, University of Siena, 53100 Siena (Italy); Maida, Isabel; Fani, Renato [Dipartimento di Biologia Evoluzionistica, Via Romana, 17, University of Florence, 50125 Florence (Italy)

    2013-08-15

    A mechanism of mercury detoxification has been suggested by a previous study on Hg bioaccumulation in Manila clams (Ruditapes philippinarum) in the polluted Marano and Grado lagoons and in this study we demonstrate that this event could be partly related to the detoxifying activities of Hg-resistant bacteria (MRB) harbored in clam soft tissues. Therefore, natural clams were collected in six stations during two different periods (winter and spring) from Marano and Grado Lagoons. Siphons, gills and hepatopancreas from acclimatized clams were sterile dissected to isolate MRB. These anatomical parts were glass homogenized or used for whole, and they were lying on a solid medium containing 5 mg l{sup −1} HgCl{sub 2} and incubated at 30 °C. A total of fourteen bacterial strains were isolated and were identified by 16S rDNA sequencing and analysis, revealing that strains were representative of eight bacterial genera, four of which were Gram-positive (Enterococcus, Bacillus, Jeotgalicoccus and Staphylococcus) and other four were Gram-negative (Stenotrophomonas, Vibrio, Raoultella and Enterobacter). Plasmids and merA genes were found and their sequences determined. Fluorescence in situ hybridization (FISH) technique shows the presence of Firmicutes, Actinobacteria and Gammaproteobacteria by using different molecular probes in siphon and gills. Bacterial clumps inside clam flesh were observed and even a Gram-negative endosymbiont was disclosed by transmission electronic microscope inside clam cells. Bacteria harbored in cavities of soft tissue have mercury detoxifying activity. This feature was confirmed by the determination of mercuric reductase in glass-homogenized siphons and gills. -- Highlights: ► We isolated Gram-positive and Gram-negative Hg resistant strains from soft tissues of Ruditapes philippinarum. ► We identify 14 mercury resistant strains by 16S rRNA gene sequences. ► Bacteria in siphon and gill tissues of clams were observed by TEM and identified

  18. Central Pressure Appraisal: Clinical Validation of a Subject-Specific Mathematical Model.

    Directory of Open Access Journals (Sweden)

    Francesco Tosello

    Full Text Available Current evidence suggests that aortic blood pressure has a superior prognostic value with respect to brachial pressure for cardiovascular events, but direct measurement is not feasible in daily clinical practice.The aim of the present study is the clinical validation of a multiscale mathematical model for non-invasive appraisal of central blood pressure from subject-specific characteristics.A total of 51 young male were selected for the present study. Aortic systolic and diastolic pressure were estimated with a mathematical model and were compared to the most-used non-invasive validated technique (SphygmoCor device, AtCor Medical, Australia. SphygmoCor was calibrated through diastolic and systolic brachial pressure obtained with a sphygmomanometer, while model inputs consist of brachial pressure, height, weight, age, left-ventricular end-systolic and end-diastolic volumes, and data from a pulse wave velocity study.Model-estimated systolic and diastolic central blood pressures resulted to be significantly related to SphygmoCor-assessed central systolic (r = 0.65 p <0.0001 and diastolic (r = 0.84 p<0.0001 blood pressures. The model showed a significant overestimation of systolic pressure (+7.8 (-2.2;14 mmHg, p = 0.0003 and a significant underestimation of diastolic values (-3.2 (-7.5;1.6, p = 0.004, which imply a significant overestimation of central pulse pressure. Interestingly, model prediction errors mirror the mean errors reported in large meta-analysis characterizing the use of the SphygmoCor when non-invasive calibration is performed.In conclusion, multi-scale mathematical model predictions result to be significantly related to SphygmoCor ones. Model-predicted systolic and diastolic aortic pressure resulted in difference of less than 10 mmHg in the 51% and 84% of the subjects, respectively, when compared with SphygmoCor-obtained pressures.

  19. Abnormal albuminuria and blood pressure rise in incipient diabetic nephropathy induced by exercise

    DEFF Research Database (Denmark)

    Christensen, Cramer

    1984-01-01

    The aim of the study was to evaluate the influence of light to moderate dynamic work (450 kpm/min followed by 600 kpm/min during 20 min each) on the blood pressure and renal protein handling in insulin-dependent diabetic patients with incipient nephropathy (D3) (elevated baseline albumin excretion...... diastolic blood pressure was elevated [92.1 mm Hg +/- 6.0 (mean +/- SD)] compared to D2 (80.9 mm Hg +/- 4.8, 2P = 0.003%) and C (79.5 mm Hg +/- 12.4, 2P = 1.2%). Baseline systolic blood pressure was not significantly different in the three groups, but systolic blood pressure was more elevated at 600 kpm...... blood pressure and maximal exercise induced albumin excretion was demonstrable in D3.(ABSTRACT TRUNCATED AT 250 WORDS)...

  20. Determination of dietary intake of total arsenic, inorganic arsenic and total mercury in the Chilean school meal program.

    Science.gov (United States)

    Bastías, J M; Bermúdez, M; Carrasco, J; Espinoza, O; Muñoz, M; Galotto, M J; Muñoz, O

    2010-10-01

    The dietary intake of total arsenic (tAs), inorganic arsenic (iAs) and total mercury (tHg) in lunch and breakfast servings provided by the Chilean School Meal Program (SMP) was estimated, using the duplicate-portion variant of the total diet study. Lunch and breakfast samples were collected from 65 schools throughout the country in 2006. The population sample was a group of girls and boys between 6 and 18 years old. The tAs concentration was measured via hydride-generation atomic absorption spectrometry. The total mercury concentration was measured via cold-vapor atomic absorption spectroscopy. The estimated iAs intake was 12.5% (5.4 μg/day) of the Provisional tolerable daily intake (PTDI) as proposed by the FAO/WHO, and the tHg intake was 13.2% (1.9 μg/day) of the PTDI as proposed by the FAO/WHO. It was therefore concluded that tAs, iAs and tHg intake from food provided by the SMP do not pose risks to student health.

  1. Identification of Potential Sources of Mercury (Hg) in Farmland Soil Using a Decision Tree Method in China.

    Science.gov (United States)

    Zhong, Taiyang; Chen, Dongmei; Zhang, Xiuying

    2016-11-09

    Identification of the sources of soil mercury (Hg) on the provincial scale is helpful for enacting effective policies to prevent further contamination and take reclamation measurements. The natural and anthropogenic sources and their contributions of Hg in Chinese farmland soil were identified based on a decision tree method. The results showed that the concentrations of Hg in parent materials were most strongly associated with the general spatial distribution pattern of Hg concentration on a provincial scale. The decision tree analysis gained an 89.70% total accuracy in simulating the influence of human activities on the additions of Hg in farmland soil. Human activities-for example, the production of coke, application of fertilizers, discharge of wastewater, discharge of solid waste, and the production of non-ferrous metals-were the main external sources of a large amount of Hg in the farmland soil.

  2. Fully relativistic coupled cluster and DFT study of electric field gradients at Hg in 199Hg compounds

    DEFF Research Database (Denmark)

    Arcisauskaité, Vaida; Knecht, Stefan; Sauer, Stephan P. A.

    2012-01-01

    We investigate the magnitude and interplay of relativistic and electron correlation effects on the electric field gradient (EFG) at the position of Hg in linear and bent HgL2 (L=CH3, Cl, Br, I) and trigonal planar [HgCl3]- complexes using four-component relativistic Dirac-Coulomb (DC) and non...

  3. High blood pressure in acute ischemic stroke and clinical outcome.

    Science.gov (United States)

    Manabe, Yasuhiro; Kono, Syoichiro; Tanaka, Tomotaka; Narai, Hisashi; Omori, Nobuhiko

    2009-11-16

    This study aimed to evaluate the prognostic value of acute phase blood pressure in patients with acute ischemic stroke by determining whether or not it contributes to clinical outcome. We studied 515 consecutive patients admitted within the first 48 hours after the onset of ischemic strokes, employing systolic and diastolic blood pressure measurements recorded within 36 hours after admission. High blood pressure was defined when the mean of at least 2 blood pressure measurements was ≥200 mmHg systolic and/or ≥110 mmHg diastolic at 6 to 24 hours after admission or ≥180 mmHg systolic and/or ≥105 mmHg diastolic at 24 to 36 hours after admission. The high blood pressure group was found to include 16% of the patients. Age, sex, diabetes mellitus, hypercholesterolemia, atrial fibrillation, ischemic heart disease, stroke history, carotid artery stenosis, leukoaraiosis, NIH Stroke Scale (NIHSS) on admission and mortality were not significantly correlated with either the high blood pressure or non-high blood pressure group. High blood pressure on admission was significantly associated with a past history of hypertension, kidney disease, the modified Rankin Scale (mRS) on discharge and the length of stay. On logistic regression analysis, with no previous history of hypertension, diabetes mellitus, atrial fibrillation, and kidney disease were independent risk factors associated with the presence of high blood pressure [odds ratio (OR), 1.85 (95% confidence interval (CI): 1.06-3.22), 1.89 (95% CI: 1.11-3.22), and 3.31 (95% CI: 1.36-8.04), respectively]. Multi-organ injury may be presented in acute stroke patients with high blood pressure. Patients with high blood pressure had a poor functional outcome after acute ischemic stroke.

  4. Determination of Hg{sup 2+} by on-line separation and pre-concentration with atmospheric-pressure solution-cathode glow discharge atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qing [Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 200050 (China); Zhang, Zhen [Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 200050 (China); School of Materials Science and Engineering, Shanghai University, Shanghai 200072 (China); Wang, Zheng, E-mail: wangzheng@mail.sic.ac.cn [Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 200050 (China)

    2014-10-03

    Highlights: • A modified SBA-15 mesoporous silica (SH-SBA-15) was synthesized as a sorbent. • On-line SPE combined with SCGD-AES based on FIA was used to detect Hg{sup 2+} firstly. • A simple, low-cost Hg{sup 2+} analysis in a complex matrix was established. • The sensitive detection of Hg{sup 2+} was achieved with a detection limit of 0.75 μg L{sup −1}. - Abstract: A simple and sensitive method to determine Hg{sup 2+} was developed by combining solution-cathode glow discharge atomic emission spectrometry (SCGD-AES) with flow injection (FI) based on on-line solid-phase extraction (SPE). We synthesized L-cysteine-modified mesoporous silica and packed it in an SPE microcolumn, which was experimentally determined to possess a good mercury adsorption capacity. An enrichment factor of 42 was achieved under optimized Hg{sup 2+} elution conditions, namely, an FI flow rate of 2.0 mL min{sup −1} and an eluent comprised of 10% thiourea in 0.2 mol L{sup −1} HNO{sub 3}. The detection limit of FI–SCGD-AES was determined to be 0.75 μg L{sup −1}, and the precision of the 11 replicate Hg{sup 2+} measurements was 0.86% at a concentration of 100 μg L{sup −1}. The proposed method was validated by determining Hg{sup 2+} in certified reference materials such as human hair (GBW09101b) and stream sediment (GBW07310)

  5. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Blood pressure targets in type 2 diabetes. Evidence against or in favour of an aggressive approach.

    Science.gov (United States)

    Mancia, Giuseppe; Grassi, Guido

    2018-03-01

    When associated with high blood pressure, type 2 diabetes mellitus is characterised by a high risk of adverse cardiovascular (CV) and renal outcomes. However, both can be effectively reduced by antihypertensive treatment. Current guidelines on the treatment of hypertension emphasize the need to effectively treat high blood pressure in diabetic individuals, but their recommendations differ in terms of the optimal target blood pressure value to aim for in order to maximise CV and renal protection. In some guidelines the recommended target blood pressure values are blood pressure values close or even less than 130/80 mmHg are recommended. This paper will discuss the evidence for and against a conservative or more aggressive blood pressure target for treated diabetic hypertensive individuals based on the evidence provided by randomised trials, trial meta-analyses and large observational studies. Based on the available evidence, it appears that blood pressure targets will probably have to be lower than <140/90 mmHg, and that values approaching 130/80 mmHg should be recommended. However, evidence in favour of even lower systolic values, i.e. <130 mmHg, is limited and is definitively against a reduction to <120 mmHg.

  7. Overcoming phytoremediation limitations. A case study of Hg contaminated soil

    Science.gov (United States)

    Barbafieri, Meri

    2013-04-01

    an increase in Hg concentration of 248% in shoots and 185% in roots with respect to control plants. The BCS efficiency were evaluated analyzing the labile-Hg residue in the soil after the plant growing. Plants grown with CK and TS in one growing cycle significantly affected labile-Hg pools in soil characterized by sequential extraction, but did not significantly reduce the total metals in the soil. Moreover, if properly optimized, the use of a coupled phytohormone/thioligand system may be a viable strategy to strength Hg uptake by crop plants.

  8. Central blood pressure in children and adolescents: non-invasive development and testing of novel transfer functions.

    Science.gov (United States)

    Cai, T Y; Qasem, A; Ayer, J G; Butlin, M; O'Meagher, S; Melki, C; Marks, G B; Avolio, A; Celermajer, D S; Skilton, M R

    2017-12-01

    Central blood pressure can be estimated from peripheral pulses in adults using generalised transfer functions (TF). We sought to create and test age-specific non-invasively developed TFs in children, with comparison to a pre-existing adult TF. We studied healthy children from two sites at two time points, 8 and 14 years of age, split by site into development and validation groups. Radial and carotid pressure waveforms were obtained by applanation tonometry. Central systolic pressure was derived from carotid waveforms calibrated to brachial mean and diastolic pressures. Age-specific TFs created in the development groups (n=50) were tested in the validation groups aged 8 (n=137) and 14 years (n=85). At 8 years of age, the age-specific TF estimated 82, 99 and 100% of central systolic pressure values within 5, 10 and 15 mm Hg of their measured values, respectively. This TF overestimated central systolic pressure by 2.2 (s.d. 3.7) mm Hg, compared to being underestimated by 5.6 (s.d. 3.9) mm Hg with the adult TF. At 14 years of age, the age-specific TF estimated 60, 87 and 95% of values within 5, 10 and 15 mm Hg of their measured values, respectively. This TF underestimated central systolic pressure by 0.5 (s.d. 6.7) mm Hg, while the adult TF underestimated it by 6.8 (s.d. 6.0) mm Hg. In conclusion, age-specific TFs more accurately predict central systolic pressure measured at the carotid artery in children than an existing adult TF.

  9. Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Bilo, Grzegorz; Zorzi, Cristina; Ochoa Munera, Juan E; Torlasco, Camilla; Giuli, Valentina; Parati, Gianfranco

    2015-10-01

    The present study aimed to evaluate the accuracy of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults (11 women, mean age 63.5±11.9 years) using a mercury sphygmomanometer (two observers) and the Somnotouch-NIBP device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the validation requirements were fulfilled. The Somnotouch-NIBP device fulfilled the requirements of the part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 75/99, 90/99, and 96/99, respectively, for systolic blood pressure and 90/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-seven and 31 participants had at least two of the three device-observers differences less than or equal to 5 mmHg for systolic and diastolic blood pressure, respectively. All three device-observer differences were greater than 5 mmHg in two participants for systolic and in one participant for diastolic blood pressure. The Somnotouch-NIBP noninvasive continuous blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure monitoring in adults, at least under conditions corresponding to those investigated in our study.

  10. Converting Hg-1212 to Tl-2212 via Tl-Hg cation exchange in combination with Tl cation intercalation

    International Nuclear Information System (INIS)

    Zhao Hua; Wu, Judy Z

    2007-01-01

    In a cation exchange process developed recently for epitaxy of HgBa 2 CaCu 2 O 6 (Hg-1212) thin films, TlBa 2 CaCu 2 O 7 (Tl-1212) or Tl 2 Ba 2 CaCu 2 O 9 (Tl-2212) precursor films were employed as the precursor matrices and Hg-1212 was obtained by replacing Tl cations on the precursor lattice with Hg cations. The reversibility of the cation exchange dictates directly the underlying mechanism. Following our recent success in demonstrating a complete reversibility within '1212' structure, we show the conversion from Hg-1212 to Tl-2212 can be achieved via two steps: conversion from Hg-1212 to Tl-1212 followed by Tl intercalation to form double Tl-O plans in each unit cell. The demonstrated reversibility of the cation exchange process has confirmed the process is a thermal perturbation of weakly bonded cations on the lattice and the direction of the process is determined by the population ratio between the replacing cations and that to be replaced

  11. Prediction of the fate of Hg and other contaminants in soil around a former chlor-alkali plant using Fuzzy Hierarchical Cross-Clustering approach.

    Science.gov (United States)

    Frenţiu, Tiberiu; Ponta, Michaela; Sârbu, Costel

    2015-11-01

    An associative simultaneous fuzzy divisive hierarchical algorithm was used to predict the fate of Hg and other contaminants in soil around a former chlor-alkali plant. The algorithm was applied on several natural and anthropogenic characteristics of soil including water leachable, mobile, semi-mobile, non-mobile fractions and total Hg, Al, Ba, Ca, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Sr, Zn, water leachable fraction of Cl(-), NO3(-) and SO4(2)(-), pH and total organic carbon. The cross-classification algorithm provided a divisive fuzzy partition of the soil samples and associated characteristics. Soils outside the perimeter of the former chlor-alkali plant were clustered based on the natural characteristics and total Hg. In contaminated zones Hg speciation becomes relevant and the assessment of species distribution is necessary. The descending order of concentration of Hg species in the test site was semi-mobile>mobile>non-mobile>water-leachable. Physico-chemical features responsible for similarities or differences between uncontaminated soil samples or contaminated with Hg, Cu, Zn, Ba and NO3(-) were also highlighted. Other characteristics of the contaminated soil were found to be Ca, sulfate, Na and chloride, some of which with influence on Hg fate. The presence of Ca and sulfate in soil induced a higher water leachability of Hg, while Cu had an opposite effect by forming amalgam. The used algorithm provided an in-deep understanding of processes involving Hg species and allowed to make prediction of the fate of Hg and contaminants linked to chlor-alkali-industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Relationship between medical compression and intramuscular pressure as an explanation of a compression paradox.

    Science.gov (United States)

    Uhl, J-F; Benigni, J-P; Cornu-Thenard, A; Fournier, J; Blin, E

    2015-06-01

    Using standing magnetic resonance imaging (MRI), we recently showed that medical compression, providing an interface pressure (IP) of 22 mmHg, significantly compressed the deep veins of the leg but not, paradoxically, superficial varicose veins. To provide an explanation for this compression paradox by studying the correlation between the IP exerted by medical compression and intramuscular pressure (IMP). In 10 legs of five healthy subjects, we studied the effects of different IPs on the IMP of the medial gastrocnemius muscle. The IP produced by a cuff manometer was verified by a Picopress® device. The IMP was measured with a 21G needle connected to a manometer. Pressure data were recorded in the prone and standing positions with cuff manometer pressures from 0 to 50 mmHg. In the prone position, an IP of less than 20 did not significantly change the IMP. On the contrary, a perfect linear correlation with the IMP (r = 0.99) was observed with an IP from 20 to 50 mmHg. We found the same correlation in the standing position. We found that an IP of 22 mmHg produced a significant IMP increase from 32 to 54 mmHg, in the standing position. At the same time, the subcutaneous pressure is only provided by the compression device, on healthy subjects. In other words, the subcutaneous pressure plus the IP is only a little higher than 22 mmHg-a pressure which is too low to reduce the caliber of the superficial veins. This is in accordance with our standing MRI 3D anatomical study which showed that, paradoxically, when applying low pressures (IP), the deep veins are compressed while the superficial veins are not. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    Science.gov (United States)

    Shangguan, Qing; Wu, Yanqing; Xu, Jinsong; Su, Hai; Li, Juxiang; Hong, Kui; Cheng, Xiaoshu

    2015-12-01

    To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP) were measured simultaneously before coronary angiography. The noninvasive BP was measured using an electronic oscillometric device with an adult cuff (12×22 cm). The mid-ACs were measured. Thus, proper cuff-arm (≤26 cm) and small cuff (>26 cm) groups were created. The difference in intra-aortic and noninvasive BP was calculated as BPi-n. The correlation coefficients (r) between noninvasive and invasive systolic blood pressure (SBP), mean artery pressure, and diastolic blood pressure (DBP) were 0.88, 0.76, and 0.58, respectively. The SBPi-n was higher (7.9±1.6 vs. 5.2±1.1 mmHg), but the DBPi-n (3.9±1.4 vs. 6.1±1.0 mmHg, P26 cm. Among the four subgroups divided by 20-23, 24-26, 27-30, and 31-37 cm of AC, as the AC increased, the SBPi-n increased, but DBP decreased, resulting in noninvasive SBP 4.6 mmHg higher and noninvasive DBP 4.6 mmHg lower in the 31-37 cm group in comparison with the 20-23 cm group. When an adult cuff was used, the noninvasive oscillometric SBP was overestimated, but DBP was underestimated in the individuals with large arms against the intra-aortic BP.

  14. Interarm difference in blood pressure

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels

    2014-01-01

    The present study aimed at examining the interarm difference in blood pressure and its use as an indicator of peripheral arterial disease (PAD). Data were included from consecutive patients referred from their general practitioner to our vascular laboratory for possible PAD aged 50 years or older...... without known cardiac disease, renal disease, or diabetes mellitus. 824 patients (453 women) with mean age of 72 years (range: 50-101) were included. 491 patients had a diagnosis of hypertension and peripheral arterial disease (PAD) was present in 386 patients. Systolic blood pressure was 143 ± 24 mm......Hg and 142 ± 24 mmHg on the right and left arm, respectively (P = 0.015). The interarm difference was greater in patients with hypertension (P = 0.002) and PAD (P blood pressure was reproducible...

  15. NAA, GC(EC) and SRXRF study of Hg species in head hair of mothers and their newborn infants

    International Nuclear Information System (INIS)

    Feng, W.Y.; Qian, Q.F.; Zhang, P.Q.; Chai, C.F.

    1995-01-01

    Twenty-seven pairs of head hair from mothers and their new-born infants were collected at the time of delivery in a hospital in Beijing. The total mercury content in the hair samples was determined by INAA. The correlation between mercury content in hair of mothers and their new-born infants has been investigated. In addition, the change of Hg content in pregnant women's hair during their pregnancy was also studied by INAA and SRXRF. The results indicate a significant positive correlation between the mercury content in maternal and infant head hairs (r = +0.862, p< 0.001). The average content of Hg in infant and maternal hairs was 0.66 ± 0.31 μg/g and 0.59 ± 0.25 μg/g, respectively. The infant level exceeded the maternal by 12%. The Hg content in maternal head hair gradually reduced during pregnancy. Further, the methylmercury (Me-Hg) content in 3 maternal hair samples was analyzed by GC(EC). The Me-Hg was in accordance with the total mercury content. Thus a conclusion can be drawn that damage to the infant from Hg occurred in the early stages of pregnancy. (author). 9 refs., 5 figs., 2 tabs

  16. Ab initio study of structural, electronic and optical properties of MnHg(SCN)4 and FeHg(SCN)4

    International Nuclear Information System (INIS)

    He, K.H.; Zheng, G.; Chen, G.; Lue, T.; Wan, M.; Ji, G.F.

    2007-01-01

    The structural, electronic and optical properties of MnHg(SCN) 4 and FeHg(SCN) 4 were studied by means of quantum-mechanical calculations based on the density-functional theory and pseudopotential method. The lattice constants can be compared with the experimental values when the effects of temperature are considered. The peaks of partial density of states of S, C, N and Hg of FeHg(SCN) 4 have a tendency of shifting to the higher energy levels relative to those of MnHg(SCN) 4 . The distributions of the 3d electronic states in the transition metal atoms show quite large difference and decide different optical properties. We found that absorptional peaks of FeHg(SCN) 4 lag behind those of MnHg(SCN) 4 and the peak in the infrared range has a higher absorptional intensity, which are in accord with the experimental results. By analyzing the distributions and transitions of the 3d electronic states, we explained the different absorption phenomena

  17. Compton profiles and electronic structure of HgBr{sub 2} and HgI{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, G.; Dashora, Alpa [Department of Physics, University College of Science, M.L. Sukhadia University, Udaipur, 313001 Rajasthan (India); Sharma, M. [Physics Division, State Forensic Science Laboratory, Jaipur, 302016 Rajasthan (India); Ahuja, B.L. [Department of Physics, University College of Science, M.L. Sukhadia University, Udaipur, 313001 Rajasthan (India)], E-mail: blahuja@yahoo.com

    2010-02-15

    In this paper, we present the first-ever experimental Compton line shapes of HgBr{sub 2} and HgI{sub 2} using {sup 137}Cs Compton spectrometer. To compare our experimental momentum densities, we have computed the Compton profiles using Hartree-Fock and density functional theory within linear combination of atomic orbitals. We have also computed the energy bands and density of states using the linear combination of atomic orbitals and full potential linearized augmented plane wave method. On the basis of equal-valence-electron-density profiles, it is seen that HgI{sub 2} is more covalent than HgBr{sub 2} which is in agreement with the valence charge densities. The experimental isotropic profiles are found to be relatively in better agreement with the Hartree-Fock data. We have also discussed the photoluminescence and detection properties of both the halides.

  18. Hg(+) Frequency Standards

    Science.gov (United States)

    Prestage, John D.; Tjoelker, Robert L.; Maleki, Lute

    2000-01-01

    In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

  19. Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation.

    Science.gov (United States)

    Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias

    2016-10-21

    The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].

  20. Ambulatory monitoring of blood pressure and pregnancy outcome in pregnant women with white coat hypertension in the third trimester of pregnancy.

    Science.gov (United States)

    Shahbazian, Nahid; Shahbazian, Heshmatollah; Mohammadjafari, Razieh; Mousavi, Mahsan

    2013-01-01

    Introduction: If the blood pressure of a pregnant woman is ≥140/90 mmHg at the clinic, but her ambulatory blood pressure is less coat hypertension. Objectives: To evaluate the value of ambulatory blood pressure monitoring in pregnant women. Patients and Methods: This prospective cohort study was conducted in Imam-Khomeini hospital of Ahwaz, Iran between 2011 to 2012. A total of 105 pregnant women who had blood pressure of higher than 140/90 mmHg during the third trimester of pregnancy were monitored. Thirty five women with white coat hypertension, 35 women with gestational hypertension and 35 women with normal blood pressure were followed. The data were analyzed using the Kolmogorov-Smirnov test, Pearson correlation coefficient and Chi-square tests. Results: The prevalence of white coat hypertension was 31.3%. The maternal and neonatal outcomes and laboratory examinations in white coat hypertension were similar to the normal blood pressure, but the frequency of caesarean section was more than the other two groups. Conclusion: The findings of the study indicate the efficacy of 24 hour holter monitoring of blood pressure and using it more comprehensively , compared to the limited visits.

  1. Baseline Blood Pressure, the 2017 ACC/AHA High Blood Pressure Guidelines, and Long-Term Cardiovascular Risk in SPRINT

    DEFF Research Database (Denmark)

    Vaduganathan, Muthiah; Pareek, Manan; Qamar, Arman

    2018-01-01

    BACKGROUND: The 2017 ACC/AHA guidelines include lower thresholds to define hypertension than previous guidelines. Little is known about the impact of these guideline changes in patients with or at high risk for cardiovascular disease. METHODS: In this exploratory analysis using baseline blood...... pressure assessments in SPRINT (Systolic Blood Pressure Intervention Trial), we evaluated the prevalence and associated cardiovascular prognosis of patients newly reclassified with hypertension based on the 2017 ACC/AHA (SBP≥130mmHg or DBP≥80mmHg) compared with the JNC 7 guidelines (SBP≥140mmHg or DBP≥90mm.......4%) were newly reclassified as having hypertension based on the 2017 ACC/AHA guidelines. Over 3.3-year median follow-up, 319 patients experienced the primary endpoint (87 of whom were newly reclassified with hypertension based on the revised guidelines). Patients with hypertension based on prior guidelines...

  2. Vertical distribution of mercury and MeHg in Nandagang and Beidagang wetlands: Influence of microtopography

    Science.gov (United States)

    Liu, Ruhai; Zhang, Yanyan; Wang, Yan; Zhao, Jin; Shan, Huayao

    2018-02-01

    Wetlands often show different small-scale topography, such as riffle, habitat island, deep water, shallow water zone and dry zone. Core soils in different micro topographical landforms of Nandagang and Beidagang wetlands in North China were sampled for THg and MeHg to analyze the influence of microtopography. Results showed that THg content in surface soil (pollution in past. High THg content in undisturbed natural wetland soil implied accumulation of mercury. Harvest of plant, drained water decreased the accumulation of mercury in wetlands. Water level caused by microtopography affected the production of MeHg. Depth of the highest MeHg content decreased from N1, N2, N6, N3 to N4 following the increase of water level. Plant type and coverage also affected the vertical distribution of MeHg. More detailed profiles of MeHg, organic matter and total phosphorus in different sites show strong differences in soil chemistry, suggesting a complex interplay among hydrology, biogeochemistry and microtopography.

  3. Hg transfer from contaminated soils to plants and animals

    NARCIS (Netherlands)

    Rodrigues, S.M.; Henriques, B.; Reis, A.T.; Duarte, A.C.; Pereira, E.; Romkens, P.F.A.M.

    2012-01-01

    Understanding the transfer of mercury (Hg) from soil to crops is crucial due to Hg toxicity and Hg occurrence in terrestrial systems. Previous research has shown that available Hg in soils contributes to plant Hg levels. Plant Hg concentrations are related to soil conditions and plant

  4. Occupational status moderates the association between current perceived stress and high blood pressure: evidence from the IPC cohort study

    Science.gov (United States)

    Wiernik, Emmanuel; Pannier, Bruno; Czernichow, Sébastien; Nabi, Hermann; Hanon, Olivier; Simon, Tabassome; Simon, Jean-Marc; Thomas, Frédérique; Bean, Kathy; Consoli, Silla; Danchin, Nicolas; Lemogne, Cédric

    2013-01-01

    Although lay beliefs commonly relate high blood pressure to psychological stress exposure, research findings are conflicting. This study examined the association between current perceived stress and high blood pressure and explored the potential impact of occupational status on this association. Resting blood pressure was measured in 122,816 adults (84,994 men), aged ≥30 years (mean age ± standard deviation: 46.8±9.9 years), without history of cardiovascular and renal disease and not on either psychotropic or antihypertensive drugs. High blood pressure was defined as systolic blood pressure ≥140 mmHg or diastolic blood pressure ≥90 mmHg. Perceived stress in the past month was measured with the 4-item perceived stress scale. A total of 33,154 participants (27.0%) had high blood pressure (151±14/90±9 mmHg). After adjustment for all variables except occupational status, perceived stress was associated with high blood pressure (odds ratio for a 5-point increase: 1.06, 95% confidence interval: [1.03–1.09]). This association was no longer significant after additional adjustment for occupational status (odds ratio: 1.01 [0.99–1.04]). There was a significant interaction (phigh blood pressure among individuals of high occupational status (odds ratio: 0.91, [0.87–0.96]) but positively associated among those of low status (odds ratio: 1.10, [1.03–1.17]) or unemployed (odds ratio: 1.13, [1.03–1.24]). Sensitivity analyses yielded similar results. The association between current perceived stress and blood pressure depends upon occupational status. This interaction may account for previous conflicting results and warrants further studies to explore its underlying mechanisms. PMID:23319539

  5. Bioaccumulation of As, Cd, Cr, Hg(II), and MeHg in killifish (Fundulus heteroclitus) from amphipod and worm prey

    Energy Technology Data Exchange (ETDEWEB)

    Dutton, Jessica, E-mail: dutton.jess@gmail.com; Fisher, Nicholas S., E-mail: nfisher@notes.cc.sunysb.edu

    2011-08-15

    Elevated metal levels in fish are a concern for the fish themselves, their predators, and possibly humans who consume contaminated seafood. Metal bioaccumulation models often rely on assimilation efficiencies (AEs) of ingested metals and loss rate constants after dietary exposure (k{sub ef}s). These models can be used to better understand processes regulating metal accumulation and can be used to make site-specific predictions of metal concentrations in animal tissues. Fish often consume a varied diet, and prey choice can influence these two parameters. We investigated the trophic transfer of As, Cd, Cr, Hg(II), and methylmercury (MeHg) from a benthic amphipod (Leptocheirus plumulosus) and an oligochaete (Lumbriculus variegatus) to killifish (Fundulus heteroclitus) using gamma-emitting radioisotopes. Except for MeHg, AEs varied between prey type. AEs were highest for MeHg (92%) and lowest for Cd (2.9-4.5%) and Cr (0.2-4%). Hg(II) showed the largest AE difference between prey type (14% amphipods, 24% worms). For Cd and Hg(II) k{sub ef}s were higher after consuming amphipods than consuming worms. Tissue distribution data shows that Cd and Hg(II) were mainly associated with the intestine, whereas As and MeHg were transported throughout the body. Calculated trophic transfer factors (TTFs) suggest that MeHg is likely to biomagnify at this trophic step at all ingestion rates, whereas As, Cd, Cr, and Hg(II) will not. Data collected in this study and others indicate that using one prey item to calculate AE and k{sub ef} could lead to an over- or underestimation of these parameters. - Highlights: {yields} We investigated the trophic transfer of metals to killifish from amphipod and worm prey. {yields} Prey choice influences metal accumulation from the diet. {yields} Only MeHg is likely to biomagnify at this trophic step.

  6. Non-invasive estimation of intracranial pressure. MR-based evaluation in children with hydrocephalus

    International Nuclear Information System (INIS)

    Muehlmann, M.; Steffinger, D.; Ertl-Wagner, B.; Koerte, I.K.; Peraud, A.; Lehner, M.; Heinen, F.; Alperin, N.

    2012-01-01

    The intracranial pressure (ICP) is a crucially important parameter for diagnostic and therapeutic decision-making in patients with hydrocephalus. So far there is no standard method to non-invasively assess the ICP. Various approaches to obtain the ICP semi-invasively or non-invasively are discussed and the clinical application of a magnetic resonance imaging (MRI)-based method to estimate ICP (MR-ICP) is demonstrated in a group of pediatric patients with hydrocephalus. Arterial inflow, venous drainage and craniospinal cerebrospinal fluid (CSF) flow were quantified using phase-contrast imaging to derive the MR-ICP. A total of 15 patients with hydrocephalus (n=9 treated with shunt placement or ventriculostomy) underwent MRI on a 3 T scanner applying retrospectively-gated cine phase contrast sequences. Of the patients six had clinical symptoms indicating increased ICP (age 2.5-14.61 years, mean 7.4 years) and nine patients had no clinical signs of elevated ICP (age 2.1-15.9 years; mean 9.8 years; all treated with shunt or ventriculostomy). Median MR-ICP in symptomatic patients was 24.5 mmHg (25th percentile 20.4 mmHg; 75th percentile 44.6 mmHg). Median MR-ICP in patients without acute signs of increased ICP was 9.8 mmHg (25th percentile 8.6 mmHg; 75th percentile 11.4 mmHg). Group differences were significant (p [de

  7. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  8. Wading bird guano contributes to Hg accumulation in tree island soils in the Florida Everglades

    International Nuclear Information System (INIS)

    Zhu, Yingjia; Gu, Binhe; Irick, Daniel L.; Ewe, Sharon; Li, Yuncong; Ross, Michael S.; Ma, Lena Q.

    2014-01-01

    Tree islands are habitat for wading birds and a characteristic landscape feature in the Everglades. A total of 93 surface soil and 3 soil core samples were collected from 7 degraded/ghost and 34 live tree islands. The mean Hg concentration in surface soils of ghost tree islands was low and similar to marsh soil. For live tree islands, Hg concentrations in the surface head region were considerably greater than those in mid and tail region, and marsh soils. Hg concentrations in bird guano (286 μg kg −1 ) were significantly higher than those in mammal droppings (105 μg kg −1 ) and plant leaves (53 μg kg −1 ). In addition, Hg concentrations and δ 15 N values displayed positive correlation in soils influenced by guano. During 1998–2010, estimated annual Hg deposition by guano was 148 μg m −2 yr −1 and ∼8 times the atmospheric deposition. Highlights: • Hg concentrations in the head region of tree islands were the highest. • Hg concentrations in bird guano (286 μg kg −1 ) were significantly higher than those in mammal droppings and plant leaves. • Hg concentrations and δ 15 N values showed positive correlation in soils influenced by guano. • Estimated annual Hg deposition by guano was 148 μg m −2 yr −1 , ∼8 times the atmospheric deposition. -- The annual Hg deposition by bird guano to tree island soils in the Everglades was ∼8 times the atmospheric deposition

  9. Measuring and understanding total dissolved gas pressure in groundwater

    Science.gov (United States)

    Ryan, C.; Roy, J. W.; Randell, J.; Castellon, L.

    2009-05-01

    Since dissolved gases are important to a number of aspects of groundwater (e.g. age dating, active or passive bioremediation, greenhouse gas fluxes, understanding biogeochemical processes involving gases, assessing potential impacts of coal bed methane activities), accurate concentration measurements, and understanding of their subsurface behaviour are important. Researchers have recently begun using total dissolved gas pressure (TGP) sensor measurements, more commonly applied for surface water monitoring, in concert with gas composition analyses to estimate more accurate groundwater gas concentrations in wells. We have used hydraulic packers to isolate the well screens where TDP is being measured, and pump tests to indicate that in-well degassing may reduce TDG below background groundwater levels. Thus, in gas-charged groundwater zones, TGPs can be considerably underestimated in the absence of pumping or screen isolation. We have also observed transient decreased TGPs during pumping that are thought to result from ebullition induced when the water table or water level in the well is lowered below a critical hydrostatic pressure.

  10. Pressure-modulation dynamic attenuated-total-reflectance (ATR) FT-IR spectroscopy

    Science.gov (United States)

    Marcott, C.; Story, G. M.; Noda, I.; Bibby, A.; Manning, C. J.

    1998-06-01

    A single-reflectance attenuated-total-reflectance (ATR) accessory with a diamond internal-reflection element was modified by the addition of a piezoelectric transducer. Initial dynamic pressure-modulation experiments have been performed in the sample compartment of a step-scanning FT-IR spectrometer. A sinusoidal pressure modulation applied to samples of isotactic polypropylene and linear low density polyethylene resulted in dynamic responses which appear to be similar to those observed in previous dynamic 2D IR experiments. Preliminary pressure-modulation dynamic ATR results are also reported for a styrene-butadiene-styrene triblock copolymer. The new method has the advantages that a much wider variety of sample types and geometries can be studied and less sample preparation is required. Dynamic 2D IR experiments carried out by ATR no longer require thin films of large area and sufficient strength to withstand the dynamic strain applied by a rheometer. The ability to obtain dynamic IR spectroscopic information from a wider variety of sample types and thicknesses would greatly expand the amount of useful information that could be extracted from normally complicated, highly overlapped IR spectra.

  11. Oblate shapes of 200,202,204Hg

    International Nuclear Information System (INIS)

    Bockisch, A.; Bharuth-Ram, K.; Kleinfeld, A.M.; Lieb, K.P.

    1979-01-01

    Measurements of the reorientation effect for the first excited 2 + states in 200 , 202 , 204 Hg were performed by exploiting the dependence of the γ-ray yield on Q 2 + for different projectiles. For 200 Hg, a positive quadrupole moment of Q 2 = 0.96 +- 0.11 eb (for negative interference) or Q 2 = 1.11 +- 0.11 eb (for positive interference) was determined indicating an oblate shape. Small positive Q 2 values were also found for 202 Hg and 204 Hg. Nine B(E2) values for excitation of the 2 + , 2 + ' and 4 + states in 196-204 Hg were measured. (orig.) [de

  12. Hg stable isotope analysis by the double-spike method.

    Science.gov (United States)

    Mead, Chris; Johnson, Thomas M

    2010-06-01

    Recent publications suggest great potential for analysis of Hg stable isotope abundances to elucidate sources and/or chemical processes that control the environmental impact of mercury. We have developed a new MC-ICP-MS method for analysis of mercury isotope ratios using the double-spike approach, in which a solution containing enriched (196)Hg and (204)Hg is mixed with samples and provides a means to correct for instrumental mass bias and most isotopic fractionation that may occur during sample preparation and introduction into the instrument. Large amounts of isotopic fractionation induced by sample preparation and introduction into the instrument (e.g., by batch reactors) are corrected for. This may greatly enhance various Hg pre-concentration methods by correcting for minor fractionation that may occur during preparation and removing the need to demonstrate 100% recovery. Current precision, when ratios are normalized to the daily average, is 0.06 per thousand, 0.06 per thousand, 0.05 per thousand, and 0.05 per thousand (2sigma) for (202)Hg/(198)Hg, (201)Hg/(198)Hg, (200)Hg/(198)Hg, and (199)Hg/(198)Hg, respectively. This is slightly better than previously published methods. Additionally, this precision was attained despite the presence of large amounts of other Hg isotopes (e.g., 5.0% atom percent (198)Hg) in the spike solution; substantially better precision could be achieved if purer (196)Hg were used.

  13. Impacts of Activated Carbon Amendment on Hg Methylation, Demethylation and Microbial Activity in Marsh Soils

    Science.gov (United States)

    Gilmour, C. C.; Ghosh, U.; Santillan, E. F. U.; Soren, A.; Bell, J. T.; Butera, D.; McBurney, A. W.; Brown, S.; Henry, E.; Vlassopoulos, D.

    2015-12-01

    In-situ sorbent amendments are a low-impact approach for remediation of contaminants in sediments, particular in habitats like wetlands that provide important ecosystem services. Laboratory microcosm trials (Gilmour et al. 2013) and early field trials show that activated carbon (AC) can effectively increase partitioning of both inorganic Hg and methylmercury to the solid phase. Sediment-water partitioning can serve as a proxy for Hg and MeHg bioavailability in soils. One consideration in using AC in remediation is its potential impact on organisms. For mercury, a critical consideration is the potential impact on net MeHg accumulation and bioavailability. In this study, we specifically evaluated the impact of AC on rates of methylmercury production and degradation, and on overall microbial activity, in 4 different Hg-contaminated salt marsh soils. The study was done over 28 days in anaerobic, sulfate-reducing slurries. A double label of enriched mercury isotopes (Me199Hg and inorganic 201Hg) was used to separately follow de novo Me201Hg production and Me199Hg degradation. AC amendments decreased both methylation and demethylation rate constants relative to un-amended controls, but the impact on demethylation was stronger. The addition of 5% (dry weight) regenerated AC to soil slurries drove demethylation rate constants to nearly zero; i.e. MeHg sorption to AC almost totally blocked its degradation. The net impact was increased solid phase MeHg concentrations in some of the soil slurries with the highest methylation rate constants. However, the net impact of AC amendments was to increase MeHg (and inorganic Hg) partitioning to the soil phase and decrease concentrations in the aqueous phase. AC significantly decreased aqueous phase inorganic Hg and MeHg concentrations after 28 days. Overall, the efficacy of AC in reducing aqueous MeHg was highest in the soils with the highest MeHg concentrations. The AC addition did not significantly impact microbial activity, as

  14. A ratiometric electrochemical biosensor for sensitive detection of Hg2+ based on thymine-Hg2+-thymine structure.

    Science.gov (United States)

    Xiong, Erhu; Wu, Liang; Zhou, Jiawan; Yu, Peng; Zhang, Xiaohua; Chen, Jinhua

    2015-01-01

    In this paper, a simple, selective and reusable electrochemical biosensor for the sensitive detection of mercury ions (Hg(2+)) has been developed based on thymine (T)-rich stem-loop (hairpin) DNA probe and a dual-signaling electrochemical ratiometric strategy. The assay strategy includes both "signal-on" and "signal-off" elements. The thiolated methylene blue (MB)-modified T-rich hairpin DNA capture probe (MB-P) firstly self-assembled on the gold electrode surface via Au-S bond. In the presence of Hg(2+), the ferrocene (Fc)-labeled T-rich DNA probe (Fc-P) hybridized with MB-P via the Hg(2+)-mediated coordination of T-Hg(2+)-T base pairs. As a result, the hairpin MB-P was opened, the MB tags were away from the gold electrode surface and the Fc tags closed to the gold electrode surface. These conformation changes led to the decrease of the oxidation peak current of MB (IMB), accompanied with the increase of that of Fc (IFc). The logarithmic value of IFc/IMB is linear with the logarithm of Hg(2+) concentration in the range from 0.5 nM to 5000 nM, and the detection limit of 0.08 nM is much lower than 10nM (the US Environmental Protection Agency (EPA) limit of Hg(2+) in drinking water). What is more, the developed DNA-based electrochemical biosensor could be regenerated by adding cysteine and Mg(2+). This strategy provides a simple and rapid approach for the detection of Hg(2+), and has promising application in the detection of Hg(2+) in real environmental samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Interactions of Hg(ii) with oligonucleotides having thymine-thymine mispairs. Optimization of an impedimetric Hg(ii) sensor.

    Science.gov (United States)

    Kamal, Ajar; She, Zhe; Sharma, Renu; Kraatz, Heinz-Bernhard

    2017-05-21

    The present work describes the effect of the number of thymine-thymine mispairs in single strand DNA probes on Hg(ii) interactions and further to develop a highly sensitive DNA based impedimetric sensor for Hg(ii) detection. To achieve this goal, the influence of the number of T-T mispairs on the signal response prompted by DNA-Hg(ii) binding interactions was examined on three designed DNA probes: 5'-OH-(CH 2 ) 6 -S-S-(CH 2 ) 6 -AGTCCACACGTTCCTTACGC-3', 5'-OH-(CH 2 ) 6 -S-S-(CH 2 ) 6 -AGTCCACATTTTCCTTTTGC-3', 5'-OH-(CH 2 ) 6 -S-S-(CH 2 ) 6 -AGTCCATTTTTTCCTTTTTT-3' having 2T-T, 4T-T and 6T-T mispairs with identical length, respectively. This study revealed that the number of T-T mispairs plays a critical role in maximizing the signal intensity of DNA-Hg(ii) binding interactions. Based on these results, DNA comprising maximum number of T-T mispairs was further utilized for construction of the Hg(ii) sensor, which exhibited a linear correlation between the change in charge transfer resistance (ΔR CT ) and the concentration of Hg(ii) over the range of 1.0 × 10 -5 M to 1.0 × 10 -10 M with a lower detection limit of 3.2 × 10 -11 M. The selectivity was tested against 12 different metal ions including Hg(ii). The ΔR CT response from Hg(ii) is 3 times higher than the nearest competitor Pb(ii) and approximately 10 times than other ions. The potential application of such a robust and label-free DNA sensor was demonstrated by analyzing environmental samples collected from Lake Ontario.

  16. Hydrogen production by the iodine-sulphur thermochemical cycle. Total and partial pressure measurements

    International Nuclear Information System (INIS)

    D Doizi; V Dauvois; J L Roujou; V Delanne; P Fauvet; B Larousse; O Hercher; P Carles; C Moulin

    2006-01-01

    The iodine sulphur thermochemical cycle appears to be one of the most promising candidate for the massive production of hydrogen using nuclear energy. The key step in this cycle is the HI distillation section which must be optimized to get a good efficiency of the overall cycle. The concept of reactive versus extractive distillation of HI has been proposed because of its potentiality. The design and the optimization of the reactive distillation column requires the knowledge of the liquid vapour equilibrium over the ternary HI-I 2 -H 2 O mixtures up to 300 C and 100 bars. A general methodology based on three experimental devices imposed by the very corrosive and concentrated media will be described: 1) I1 for the total pressure measurement versus different ternary compositions. 2) I2 for the partial and total pressure measurements around 130 C and 2 bars to validate the choice of the analytical optical 'online' techniques we have proposed. 3) I3 for the partial and total pressures measurements in the process domain. The results obtained on pure samples, binary mixtures HI-H 2 O and ternary mixtures using an experimental design analysis in the experimental device I2 will be discussed. (authors)

  17. The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    Science.gov (United States)

    Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard

    2017-10-01

    Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Nocturnal Blood Pressure Variability in Patients with Obstructive Sleep Apnea Syndrome.

    Science.gov (United States)

    Martynowicz, H; Porębska, I; Poręba, R; Mazur, G; Brzecka, A

    2016-01-01

    Obstructive sleep apnea (OSA) is a common respiratory disorder associated with hypertension and cardiovascular complications. Blood pressure variability may be a sign of risk of cardiovascular events. The aim of this study was to investigate the hypothesis that severe OSA syndrome is associated with increased blood pressure variability. Based on respiratory polygraphy, 58 patients were categorized into two groups: severe OSA with apnea/hypopnea index (AHI) greater than 29 episodes per hour (mean 52.2 ± 19.0/h) and mild-to-moderate OSA with AHI between 5 and 30 episodes per hour (mean 20.2 ± 7.8/h). A 24-h noninvasive blood pressure monitoring was performed. The standard deviation of mean blood pressure was used as the indicator of blood pressure variability. In patients with severe, compared with mild-to-moderate OSA, a higher mean nocturnal systolic blood pressure (133.2 ± 17.4 mmHg vs. 117.7 ± 31.2 mmHg, p variability (12.1 ± 6.0 vs. 7.6 ± 4.3, p variability (10.5 ± 6.1 vs. 7.3 ± 4.0 p variability (9.1 ± 4.9 mmHg vs. 6.8 ± 3.5 mmHg) were detected. The findings of the study point to increased nocturnal systolic and diastolic arterial blood pressure and blood pressure variability as risk factors of cardiovascular complications in patients with severe OSA.

  19. The intraventricular filling vortex under heightened aortic blood pressure

    Science.gov (United States)

    Nelsen, Nicholas; Gaddam, Manikantam; Santhanakrishnan, Arvind

    2017-11-01

    Hypertension, or high aortic blood pressure, can induce structural changes in the left ventricle (LV) such as concentric hypertrophy. Previous studies have identified that the intraventricular filling vortex serves as an effective means of blood transport during diastolic filling. However, a fundamental understanding of how hypertension affects this vortex is unavailable. This knowledge can be useful for improving diagnosis and treatment of related heart disease conditions, including hypertensive heart failure. In this experimental study, we hypothesized that the circulation of the filling vortex would diminish with increased aortic pressure. Using a LV physical model within a left heart simulator, we performed hemodynamic measurements to acquire pressure and volumetric inflow profiles and 2D particle image velocimetry to visualize the intraventricular flow fields. Peak aortic pressures of 120 mm Hg, 140 mm Hg, and 160 mm Hg were each tested at heart rates of 70, 100, and 110 beats per minute, under: 1) reduced ejection fraction (EF), and 2) constant EF. Our results indicate that peak vortex circulation is reduced under elevated aortic pressures. Hemodynamics and characteristics of the intraventricular filling vortex in all examined experimental cases will be presented.

  20. Assessment of Hg Pollution Released from a WWII Submarine Wreck (U-864) by Hg Isotopic Analysis of Sediments and Cancer pagurus Tissues.

    Science.gov (United States)

    Rua-Ibarz, Ana; Bolea-Fernandez, Eduardo; Maage, Amund; Frantzen, Sylvia; Valdersnes, Stig; Vanhaecke, Frank

    2016-10-04

    Hg pollution released from the U-864 submarine sunk during WWII and potential introduction of that Hg into the marine food chain have been studied by a combination of quantitative Hg and MeHg determination and Hg isotopic analysis via cold vapor generation multicollector inductively coupled plasma-mass spectrometry (CVG-MC-ICP-MS) in sediment and Cancer pagurus samples. The sediment pollution could be unequivocally linked with the metallic Hg present in the wreck. Crabs were collected at the wreck location and 4 nmi north and south, and their brown and claw meat were analyzed separately. For brown meat, the δ 202 Hg values of the individuals from the wreck location were shifted toward the isotopic signature of the sediment and, thus, the submarine Hg. Such differences were not found for claw meat. The isotope ratio results suggest direct ingestion of metallic Hg by C. pagurus but do not offer any proof for any other introduction of the submarine Hg into the marine food chain.

  1. Target blood pressure for treatment of isolated systolic hypertension in the elderly: valsartan in elderly isolated systolic hypertension study.

    Science.gov (United States)

    Ogihara, Toshio; Saruta, Takao; Rakugi, Hiromi; Matsuoka, Hiroaki; Shimamoto, Kazuaki; Shimada, Kazuyuki; Imai, Yutaka; Kikuchi, Kenjiro; Ito, Sadayoshi; Eto, Tanenao; Kimura, Genjiro; Imaizumi, Tsutomu; Takishita, Shuichi; Ueshima, Hirotsugu

    2010-08-01

    In this prospective, randomized, open-label, blinded end point study, we aimed to establish whether strict blood pressure control ( or =140 mm Hg to or =2 years. The strict control (1545 patients) and moderate control (1534 patients) groups were well matched (mean age: 76.1 years; mean blood pressure: 169.5/81.5 mm Hg). Median follow-up was 3.07 years. At 3 years, blood pressure reached 136.6/74.8 mm Hg and 142.0/76.5 mm Hg, respectively. The blood pressure difference between the 2 groups was 5.4/1.7 mm Hg. The overall rate of the primary composite end point was 10.6 per 1000 patient-years in the strict control group and 12.0 per 1000 patient-years in the moderate control group (hazard ratio: 0.89; [95% CI: 0.60 to 1.34]; P=0.38). In summary, blood pressure targets of or = 70 years of age with isolated systolic hypertension, although our trial was underpowered to definitively determine whether strict control was superior to less stringent blood pressure targets.

  2. Determinants of the Morning-Evening Home Blood Pressure Difference in Treated Hypertensives: The HIBA-Home Study

    Directory of Open Access Journals (Sweden)

    Lucas S. Aparicio

    2014-01-01

    Full Text Available Background. The morning home blood pressure (BP rise is a significant asymptomatic target organ damage predictor in hypertensives. Our aim was to evaluate determinants of home-based morning-evening difference (MEdiff in Argentine patients. Methods. Treated hypertensive patients aged ≥18 years participated in a cross-sectional study, after performing home morning and evening BP measurement. MEdiff was morning minus evening home average results. Variables identified as relevant predictors were entered into a multivariable linear regression analysis model. Results. Three hundred sixty-seven medicated hypertensives were included. Mean age was 66.2 (14.5, BMI 28.1 (4.5, total cholesterol 4.89 (1.0 mmol/L, 65.9% women, 11.7% smokers, and 10.6% diabetics. Mean MEdiff was 1.1 (12.5 mmHg systolic and 2.3 (6.1 mmHg diastolic, respectively. Mean self-recorded BP was 131.5 (14.1 mmHg systolic and 73.8 (7.6 mmHg diastolic, respectively. Mean morning and evening home BPs were 133.1 (16.5 versus 132 (15.7 systolic and 75.8 (8.4 versus 73.5 (8.2 diastolic, respectively. Significant beta-coefficient values were found in systolic MEdiff for age and smoking and in diastolic MEdiff for age, smoking, total cholesterol, and calcium-channel blockers. Conclusions. In a cohort of Argentine medicated patients, older age, smoking, total cholesterol, and use of calcium channel blockers were independent determinants of home-based MEdiff.

  3. Changes in subcutaneous blood flow during locally applied negative pressure to the skin

    DEFF Research Database (Denmark)

    Skagen, K; Henriksen, O

    1983-01-01

    The effect of locally applied subatmospheric pressure on subcutaneous blood flow was studied in 12 healthy subjects. Blood flow was measured on the forearm by the local 133Xe wash-out technique. Air suction between 10 mmHg and 250 mmHg was applied to the skin. Subatmospheric pressure of 20 mm...

  4. Blood pressure and social support observations from Mamre, South Africa, during social and political transition.

    Science.gov (United States)

    Daniels, A; Hoffman, M; Lombard, C; Steyn, K; Levitt, N; Katzenellenbogen, J

    1999-10-01

    Social support, by moderating cardiovascular reactivity, has been demonstrated to attenuate the effects of stress on blood pressure in American communities. This is the first report to examine the relationship between social support and blood pressure in a South African context, during a period of infrastructure modernisation and political change. A total of 1240 residents (542 men, 698 women) of mixed ethnic origin, older than 14 years and stratified by age and sex, participated in a survey to determine risk factors for hypertension and cardiovascular diseases. Social support was assessed by a questionnaire developed in consultation with the community. It was defined by interactions that may threaten family harmony (score 1) and by networking between relatives, friends, colleagues and neighbours (score 2). Mean blood pressure of the sample was 130/79 mm Hg (s.d. 25/14 mm Hg). Hypertension prevalence was 26.9%. Only 36% of women compared to 57.3% of men (P social support networks were similarly perceived by both sexes. Systolic and diastolic blood pressure correlated weakly with score 1 (r = 0.096, P networking between relatives, friends or neighbours, significantly influences blood pressure in this community. Measures of social support thought to moderate blood pressure may have limited cross-cultural application. Attitudinal changes during socio-political transition may impact on the generalisability of instruments for measurement.

  5. Pressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model.

    Science.gov (United States)

    Chopra, Sascha Santosh; Wolf, Stefan; Rohde, Veit; Freimann, Florian Baptist

    2015-01-01

    Introduction. Intra-abdominal pressure (IAP) measurement is an indispensable tool for the diagnosis of abdominal hypertension. Different techniques have been described in the literature and applied in the clinical setting. Methods. A porcine model was created to simulate an abdominal compartment syndrome ranging from baseline IAP to 30 mmHg. Three different measurement techniques were applied, comprising telemetric piezoresistive probes at two different sites (epigastric and pelvic) for direct pressure measurement and intragastric and intravesical probes for indirect measurement. Results. The mean difference between the invasive IAP measurements using telemetric pressure probes and the IVP measurements was -0.58 mmHg. The bias between the invasive IAP measurements and the IGP measurements was 3.8 mmHg. Compared to the realistic results of the intraperitoneal and intravesical measurements, the intragastric data showed a strong tendency towards decreased values. The hydrostatic character of the IAP was eliminated at high-pressure levels. Conclusion. We conclude that intragastric pressure measurement is potentially hazardous and might lead to inaccurately low intra-abdominal pressure values. This may result in missed diagnosis of elevated abdominal pressure or even ACS. The intravesical measurements showed the most accurate values during baseline pressure and both high-pressure plateaus.

  6. Exploring the Hg pollution in global marginal seas by trophic biomagnification in demersal fishes

    Science.gov (United States)

    Tseng, C. M.; Hsieh, Y. C.; Chiang, C. Y.; Lamborg, C. H.; Chang, N. N.; Shiao, J. C.

    2017-12-01

    Limited knowledge still exists concerning the effects of size composition and trophic level (TL) on mercury levels in the demersal fishes associated with human activities in the marginal seas. In this study, we found evidence of strong control of TL on the Hg in fish and its biomagnification via food webs in the ECS. Total Hg in seven selected fish species, collected during the cruise OR1- 890 in July 2009, ranged from 2.6 and 256.2 ng g-1 (n=72). There were good linear relationships between Hg concentrations and fish body length (R2 = 0.79) and weight (R2 = 0.82), respectively, other than environmental variables (R2 = 0 0.03). It indicates that the Hg concentration in fish is mainly controlled by the growth mechanism of the fish itself through food chain transfer. In order to investigate how Hg levels in fish through trophic magnification associated with environmental changes, we hence developed the empirical method to calculate Hg accumulation rate (MAR) via the relationship of Hg concentration with the fish age for each fish species. The results further showed a significantly positive correlation of MAR with trophic levels, which relationship is Ln MAR =6.1 TL-15.8 (R2 = 0.89) in the ECS shelf. The magnitude of the slope (δMAR/δTL) as a biomagnification index of demersal fish shall provide the feasibility to compare Hg pollution situation among different marine ecosystems. Globally, the biomagnification indicator in the demersal fishes of the ECS is much greater than those in other marginal seas, suggesting high regional Hg pollution impacts from Mainland China.

  7. Single crystal growth, electronic structure and optical properties of Cs2HgBr4

    Science.gov (United States)

    Lavrentyev, A. A.; Gabrelian, B. V.; Vu, V. T.; Shkumat, P. N.; Parasyuk, O. V.; Fedorchuk, A. O.; Khyzhun, O. Y.

    2015-10-01

    We report on successful synthesis of high-quality single crystal of cesium mercury tetrabromide, Cs2HgBr4, by using the vertical Bridgman-Stockbarger method as well as on studies of its electronic structure. For the Cs2HgBr4 crystal, we have recorded X-ray photoelectron spectra for both pristine and Ar+ ion-bombarded surfaces. Our data indicate that the Cs2HgBr4 single crystal surface is rather sensitive with respect to Ar+ ion-bombardment. In particular, such a treatment of the Cs2HgBr4 single crystal surface alters its elemental stoichiometry. To explore peculiarities of the energy distribution of total and partial densities of states within the valence band and the conduction band of Cs2HgBr4, we have made band-structure calculations based on density functional theory (DFT) employing the augmented plane wave+local orbitals (APW+lo) method as incorporated in the WIEN2k package. The APW+lo calculations allow for concluding that the Br 4p states make the major contributions in the upper portion of the valence band, while its lower portion is dominated by contributors of the Hg 5d and Cs 5p states. Further, the main contributors to the bottom of the conduction band of Cs2HgBr4 are the unoccupied Br p and Hg s states. In addition, main optical characteristics of Cs2HgBr4 such as dispersion of the absorption coefficient, real and imaginary parts of dielectric function, electron energy-loss spectrum, refractive index, extinction coefficient and optical reflectivity have been explored from the first-principles band-structure calculations.

  8. Hg concentrations and related risk assessment in coral reef crustaceans, molluscs and fish from New Caledonia.

    Science.gov (United States)

    Chouvelon, Tiphaine; Warnau, Michel; Churlaud, Carine; Bustamante, Paco

    2009-01-01

    There is a dramatic lack of data on Hg levels in marine organisms from tropical areas, and in particular from New Caledonia. For the first time, this study reports the total Hg concentrations in the tissues of several marine taxa from the New Caledonian lagoon. Seafood from both wild and farmed populations was considered. Hg concentrations varied over three orders of magnitudes according to factors including species, age (size/weight), trophic level, lifestyle and geographical origin. Taking into account the edible tissues, estimations of the amount of flesh that should be consumed by a 60-kg person to reach the Hg Provisional Tolerable Weekly Intake (PTWI) reveal acceptable risk for Human health in general. However, a risk was clearly identified in one site of the lagoon (i.e. Grande Rade) where high Hg concentrations were measured. These concentrations were higher than values reported in the current literature.

  9. Sources of dietary protein in relation to blood pressure in a general Dutch population.

    Directory of Open Access Journals (Sweden)

    Wieke Altorf-van der Kuil

    Full Text Available BACKGROUND: Little is known about the relation of different dietary protein types with blood pressure (BP. We examined whether intake of total, plant, animal, dairy, meat, and grain protein was related to BP in a cross sectional cohort of 20,820 Dutch adults, aged 20-65 y and not using antihypertensive medication. DESIGN: Mean BP levels were calculated in quintiles of energy-adjusted protein with adjustment for age, sex, BMI, education, smoking, and intake of energy, alcohol, and other nutrients including protein from other sources. In addition, mean BP difference after substitution of 3 en% carbohydrates or MUFA with protein was calculated. RESULTS: Total protein and animal protein were not associated with BP (p(trend = 0.62 and 0.71 respectively, both at the expense of carbohydrates and MUFA. Systolic BP was 1.8 mmHg lower (p(trend36 g/d than in the lowest (<27 g/d quintile of plant protein. This inverse association was present both at the expense of carbohydrates and MUFA and more pronounced in individuals with untreated hypertension (-3.6 mmHg than in those with normal (+0.1 mmHg or prehypertensive BP (-0.3 mmHg; p(interaction<0.01. Meat and grain protein were not related to BP. Dairy protein was directly associated with systolic BP (+1.6 mmHg, p(trend<0.01, but not with diastolic BP (p(trend = 0.24. CONCLUSIONS: Total protein and animal protein were not associated with BP in this general untreated Dutch population. Plant protein may be beneficial to BP, especially in people with elevated BP. However, because high intake of plant protein may be a marker of a healthy diet and lifestyle in general, confirmation from randomized controlled trials is warranted.

  10. Sixteen-Day Bedrest Significantly Increases Plasma Colloid Osmotic Pressure

    Science.gov (United States)

    Hargens, Alan R.; Hsieh, S. T.; Murthy, G.; Ballard, R. E.; Convertino, V. A.; Wade, Charles E. (Technical Monitor)

    1994-01-01

    Upon exposure to microgravity, astronauts lose up to 10% of their total plasma volume, which may contribute to orthostatic intolerance after space flight. Because plasma colloid osmotic pressure (COP) is a primary factor maintaining plasma volume, our objective was to measure time course changes in COP during microgravity simulated by 6 deg. head-down tilt (HDT). Seven healthy male subjects (30-55 years of age) were placed in HDT for 16 days. For the purpose of another study, three of the seven subjects were chosen to exercise on a cycle ergometer on day 16. Blood samples were drawn immediately before bedrest on day 14 of bedrest, 18-24 hours following exercise while all subjects were still in HDT and 1 hour following bedrest termination. Plasma COP was measured in all 20 microliter EDTA-treated samples using an osmometer fitted with a PM 30 membrane. Data were analyzed with paired and unpaired t-tests. Plasma COP on day 14 of bedrest (29.9 +/- 0.69 mmHg) was significantly higher (p less than 0.005) than the control, pre-bedrest value (23.1 +/- 0.76 mmHg). At one hour of upright recovery after HDT, plasma COP remained significantly elevated (exercise: 26.9 +/- 0.87 mmHg; no exercise: 26.3 +/- 0.85 mmHg). Additionally, exercise had no significant effect on plasma COP 18-24 hours following exercise (exercise: 27.8 +/- 1.09 mmHg; no exercise: 27.1 +/- 0.78 mmHg). Our results demonstrate that plasma COP increases significantly with microgravity simulated by HDT. However, preliminary results indicate exercise during HDT does not significantly affect plasma COP.

  11. 40 CFR 60.4111 - Alternate Hg designated representative.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Alternate Hg designated representative... Times for Coal-Fired Electric Steam Generating Units Hg Designated Representative for Hg Budget Sources § 60.4111 Alternate Hg designated representative. (a) A certificate of representation under § 60.4113...

  12. Effect of CPAP on blood pressure in patients with obstructive sleep apnea and resistant hypertension: the HIPARCO randomized clinical trial.

    Science.gov (United States)

    Martínez-García, Miguel-Angel; Capote, Francisco; Campos-Rodríguez, Francisco; Lloberes, Patricia; Díaz de Atauri, María Josefa; Somoza, María; Masa, Juan F; González, Mónica; Sacristán, Lirios; Barbé, Ferrán; Durán-Cantolla, Joaquín; Aizpuru, Felipe; Mañas, Eva; Barreiro, Bienvenido; Mosteiro, Mar; Cebrián, Juan J; de la Peña, Mónica; García-Río, Francisco; Maimó, Andrés; Zapater, Jordi; Hernández, Concepción; Grau SanMarti, Nuria; Montserrat, Josep María

    2013-12-11

    More than 70% of patients with resistant hypertension have obstructive sleep apnea (OSA). However, there is little evidence about the effect of continuous positive airway pressure (CPAP) treatment on blood pressure in patients with resistant hypertension. To assess the effect of CPAP treatment on blood pressure values and nocturnal blood pressure patterns in patients with resistant hypertension and OSA. Open-label, randomized, multicenter clinical trial of parallel groups with blinded end point design conducted in 24 teaching hospitals in Spain involving 194 patients with resistant hypertension and an apnea-hypopnea index (AHI) of 15 or higher. Data were collected from June 2009 to October 2011. CPAP or no therapy while maintaining usual blood pressure control medication. The primary end point was the change in 24-hour mean blood pressure after 12 weeks. Secondary end points included changes in other blood pressure values and changes in nocturnal blood pressure patterns. Both intention-to-treat (ITT) and per-protocol analyses were performed. A total of 194 patients were randomly assigned to receive CPAP (n = 98) or no CPAP (control; n = 96). The mean AHI was 40.4 (SD, 18.9) and an average of 3.8 antihypertensive drugs were taken per patient. Baseline 24-hour mean blood pressure was 103.4 mm Hg; systolic blood pressure (SBP), 144.2 mm Hg; and diastolic blood pressure (DBP), 83 mm Hg. At baseline, 25.8% of patients displayed a dipper pattern (a decrease of at least 10% in the average nighttime blood pressure compared with the average daytime blood pressure). The percentage of patients using CPAP for 4 or more hours per day was 72.4%. When the changes in blood pressure over the study period were compared between groups by ITT, the CPAP group achieved a greater decrease in 24-hour mean blood pressure (3.1 mm Hg [95% CI, 0.6 to 5.6]; P = .02) and 24-hour DBP (3.2 mm Hg [95% CI, 1.0 to 5.4]; P = .005), but not in 24-hour SBP (3.1 mm Hg [95% CI, -0.6 to 6

  13. Effects of nattokinase on blood pressure: a randomized, controlled trial.

    Science.gov (United States)

    Kim, Ji Young; Gum, Si Nae; Paik, Jean Kyung; Lim, Hyo Hee; Kim, Kyong-Chol; Ogasawara, Kazuya; Inoue, Kenichi; Park, Sungha; Jang, Yangsoo; Lee, Jong Ho

    2008-08-01

    The objective of this study was to examine the effects of nattokinase supplementation on blood pressure in subjects with pre-hypertension or stage 1 hypertension. In a randomized, double-blind, placebo-controlled trial, 86 participants ranging from 20 to 80 years of age with an initial untreated systolic blood pressure (SBP) of 130 to 159 mmHg received nattokinase (2,000 FU/capsule) or a placebo capsule for 8 weeks. Seventy-three subjects completed the protocol. Compared with the control group, the net changes in SBP and diastolic blood pressure (DBP) were -5.55 mmHg (95% confidence interval [CI], -10.5 to -0.57 mmHg; pnattokinase group compared with the control group (pnattokinase supplementation resulted in a reduction in SBP and DBP. These findings suggest that increased intake of nattokinase may play an important role in preventing and treating hypertension.

  14. Role of different negative pressure values in the process of infected wounds treated by vacuum-assisted closure: an experimental study.

    Science.gov (United States)

    Zhou, Min; Yu, Aixi; Wu, Gang; Xia, Chengyan; Hu, Xiang; Qi, Baiwen

    2013-10-01

    Vacuum-assisted closure (VAC) device is widely used to treat infected wounds in clinical work. Although the effect of VAC with different negative pressure values is well established, whether different negative pressures could result in varying modulation of wound relative cytokines was not clear. We hypothesise that instead of the highest negative pressure value the suitable value for VAC is the one which is the most effective on regulating wound relative cytokines. Infected wounds created on pigs' back were used to investigate the effects of varying negative pressure values of VAC devices. Wounds were treated with VAC of different negative pressure values or moist gauze, which was set as control. The VAC foam, semiocclusive dresses and moist gauze were changed on days 3, 5, 7 and 9 after wounds were created. When changing dressings, tissues from wounds were harvested for bacteria count and histology examination including Masson's trichrome stain and immunohistochemistry for microvessels. Western blot was carried out to test the expression of vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF). Results showed that on days 3 and 5 the number of bacteria in wounds treated by VAC with 75, 150, 225 and 300 mmHg was significantly decreased compared with that in wounds treated by gauze and 0 mmHg pressure value. However, there was no difference in wounds treated with negative pressure values of 75 , 150, 225 and 300 mmHg at any time spot. Immunohistochemistry showed that more microvessels were generated in wounds treated by VAC using 75 and 150 mmHg negative pressure comparing with that using 225 and 300 mmHg on days 3 and 5. However this difference vanished on days 7 and 9. Morphological evaluation by Masson's trichrome staining showed increased collagen deposition in VAC of 75 and 150 mmHg compared with that in VAC of 225 and 300 mmHg. Western blot showed that the expression of VEGF and bFGF significantly increased when the wounds

  15. Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.

    Science.gov (United States)

    Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich

    2017-02-01

    At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgstandard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  17. Seaweed intake and blood pressure levels in healthy pre-school Japanese children

    Directory of Open Access Journals (Sweden)

    Yamamoto Keiko

    2011-08-01

    Full Text Available Abstract Background Few studies have examined whether dietary factors might affect blood pressure in children. We purposed to investigate whether seaweed intake is associated with blood pressure level among Japanese preschool children. Methods The design of the study was cross-sectional and it was conducted in autumn 2006. Subjects were healthy preschoolers aged 3-6 years in Aichi, Japan. Blood pressure and pulse were measured once by an automated sphygmomanometer, which uses oscillometric methods. Dietary data, including seaweed intake, were assessed using 3-day dietary records covering 2 consecutive weekdays and 1 weekend day. Of a total of 533 children, 459 (86.1 percent agreed to be enrolled in our study. Finally, blood pressure measurement, complete dietary records and parent-reported height and weight were obtained for 223 boys and 194 girls. Results When we examined Spearman's correlation coefficients, seaweed intake was significantly negatively related to systolic blood pressure in girls (P = 0.008. In the one-way analysis of covariance for blood pressure and pulse after adjustments for age and BMI, the boys with the lowest, middle and highest tertiles of seaweed intake had diastolic blood pressure readings of 62.8, 59.3 and 59.6 mmHg, respectively (P = 0.11, trend P = 0.038. Girls with higher seaweed intake had significantly lower systolic blood pressure readings (102.4, 99.2 and 96.9 mmHg for girls with the lowest, middle and highest tertiles of seaweed intake, respectively; P = 0.037, trend P = 0.030. Conclusion Our study showed that seaweed intake was negatively related to diastolic blood pressure in boys and to systolic blood pressure in girls. This suggests that seaweed might have beneficial effects on blood pressure among children.

  18. Increase in vagal activity during hypotensive lower-body negative pressure in humans

    DEFF Research Database (Denmark)

    Sander-Jensen, K; Mehlsen, J; Stadeager, C

    1988-01-01

    Progressive central hypovolemia is characterized by a normotensive, tachycardic stage followed by a reversible, hypotensive stage with slowing of the heart rate (HR). We investigated circulatory changes and arterial hormone concentrations in response to lower-body negative pressure (LBNP) in six...... volunteers before and after atropine administration. LBNP of 55 mmHg initially resulted in an increase in HR from 55 +/- 4 to 90 +/- 5 beats/min and decreases in mean arterial pressure (MAP) from 94 +/- 4 to 81 +/- 5 mmHg, in central venous pressure from 7 +/- 1 to -3 +/- 1 mmHg, and in cardiac output from 6.......1 +/- 0.5 to 3.7 +/- 0.11/min. Concomitantly, epinephrine and norepinephrine levels increased. After 8.2 +/- 2.3 min of LBNP, the MAP had decreased to 41 +/- 7 mmHg and HR had decreased to 57 +/- 3 beats/min. Vasopressin increased from 1.2 +/- 0.3 to 137 +/- 45 pg/ml and renin activity increased from 1...

  19. Hg concentrations and related risk assessment in coral reef crustaceans, molluscs and fish from New Caledonia

    International Nuclear Information System (INIS)

    Chouvelon, Tiphaine; Warnau, Michel; Churlaud, Carine; Bustamante, Paco

    2009-01-01

    There is a dramatic lack of data on Hg levels in marine organisms from tropical areas, and in particular from New Caledonia. For the first time, this study reports the total Hg concentrations in the tissues of several marine taxa from the New Caledonian lagoon. Seafood from both wild and farmed populations was considered. Hg concentrations varied over three orders of magnitudes according to factors including species, age (size/weight), trophic level, lifestyle and geographical origin. Taking into account the edible tissues, estimations of the amount of flesh that should be consumed by a 60-kg person to reach the Hg Provisional Tolerable Weekly Intake (PTWI) reveal acceptable risk for Human health in general. However, a risk was clearly identified in one site of the lagoon (i.e. Grande Rade) where high Hg concentrations were measured. These concentrations were higher than values reported in the current literature. - This work reports the first assessment of Hg levels in edible organisms from the New Caledonian lagoon and the associated risk linked to their consumption by Human

  20. Hg concentrations and related risk assessment in coral reef crustaceans, molluscs and fish from New Caledonia

    Energy Technology Data Exchange (ETDEWEB)

    Chouvelon, Tiphaine [Littoral Environnement et Societes (LIENSs), UMR 6250, CNRS-Universite La Rochelle, 2 Rue Olympe de Gouges, F-17042 La Rochelle Cedex 01 (France); Warnau, Michel [International Atomic Energy Agency-Marine Environment Laboratories (IAEA-MEL), 4 Quai Antoine Ier, MC-98000 (Monaco); Churlaud, Carine [Federation de Recherche en Environnement pour le Developpement Durable (FR-EDD), FR CNRS 3097, Centre Commun d' Analyses, 5 Perspectives de l' Ocean, F-17071 La Rochelle Cedex 9 (France); Bustamante, Paco [Littoral Environnement et Societes (LIENSs), UMR 6250, CNRS-Universite La Rochelle, 2 Rue Olympe de Gouges, F-17042 La Rochelle Cedex 01 (France)], E-mail: pbustama@univ-lr.fr

    2009-01-15

    There is a dramatic lack of data on Hg levels in marine organisms from tropical areas, and in particular from New Caledonia. For the first time, this study reports the total Hg concentrations in the tissues of several marine taxa from the New Caledonian lagoon. Seafood from both wild and farmed populations was considered. Hg concentrations varied over three orders of magnitudes according to factors including species, age (size/weight), trophic level, lifestyle and geographical origin. Taking into account the edible tissues, estimations of the amount of flesh that should be consumed by a 60-kg person to reach the Hg Provisional Tolerable Weekly Intake (PTWI) reveal acceptable risk for Human health in general. However, a risk was clearly identified in one site of the lagoon (i.e. Grande Rade) where high Hg concentrations were measured. These concentrations were higher than values reported in the current literature. - This work reports the first assessment of Hg levels in edible organisms from the New Caledonian lagoon and the associated risk linked to their consumption by Human.

  1. Renoprotection with and without blood pressure reduction

    DEFF Research Database (Denmark)

    Laverman, Gozewijn Dirk; Andersen, Steen; Rossing, Peter

    2005-01-01

    BACKGROUND: AT1-receptor blockade dose dependently lowers blood pressure (BP) and albuminuria. Reduction of BP and albuminuria are independent treatment targets for renoprotection, but whether this requires similar dose titration is unknown. METHODS: We tested this in two studies designed to find...... arterial pressure (MAP) were measured. Patients were divided into "good" and "poor" BP responders (BP+, BP-) according to BP response above or below group median. RESULTS: Baseline MAP in the BP- groups was 102 (97, 104) mm Hg in DM (median, 95% CI) and 91 (80, 108) mm Hg in ND. The top of the dose...

  2. Efficacy of a classical antiobesity Unani pharmacopial formulation (Safoof-e-Muhazzil in systolic and diastolic blood pressure: A randomized, open-labeled, controlled clinical study

    Directory of Open Access Journals (Sweden)

    Asim Ali Khan

    2013-01-01

    Full Text Available The aim of this study is to evaluate the efficacy of a Unani formulation in hypertension. A total of 90 patients with total cholesterol level of more than 220 mg/dl with associated conditions were included in this study. A total of 30 patients having a mean systolic blood pressure (BP of 133.86 mmHg comprising Group A received Unani formulation Safoof-e-Muhazzil (SM in its classical powder form in the dose of 5 g twice a day orally. Group B comprising of 30 patients with a mean systolic BP of 133.13 mmHg received same drug, but in compressed tablet form in the same dosage, whereas, 30 patients comprising Group C with a mean systolic BP of 129.45 mmHg, received Atorvastatin 10 mg as a standard control. Patients were evaluated on each follow-up at 2 nd , 4 th and 6 th week. The mean systolic BP in Group A and B before treatment was 133.86 ± 3.028 mmHg and 133.13 ± 2.852 mmHg, which significantly decreased to 119.33 ± 1.922 mmHg (P < 0.001 and 119 ± 1.760 mmHg (P < 0.001 respectively. In the control Group C before treatment BP was 129.45 ± 2.499 mmHg and after treatment it significantly decreased to 124.34 ± 1.794 mmHg (P < 0.01. The percentage change after treatment was 10.85%, 10.61% and 3.94% respectively in each group. Mean diastolic BP in Group A and B before treatment was 85.06 ± 2.11 mmHg and 84.56 ± 1.5 mmHg, which significantly decreased to 79.06 ± 1.56 mmHg (P < 0.001 and 79.96 ± 1.15 mmHg (P < 0.001 respectively, BP before treatment in Group C was 83.23 ± 1.588 mmHg, which was decreased to 124.34 ± 1.794 mmHg (P < 0.01. The study results indicate that the test drug was quite effective in reducing both systolic as well as diastolic BP.

  3. Baseline Blood Pressure, the 2017 ACC/AHA High Blood Pressure Guidelines, and Long-Term Cardiovascular Risk in SPRINT.

    Science.gov (United States)

    Vaduganathan, Muthiah; Pareek, Manan; Qamar, Arman; Pandey, Ambarish; Olsen, Michael H; Bhatt, Deepak L

    2018-02-05

    The 2017 American College of Cardiology (ACC)/American Heart Association (AHA) guidelines include lower thresholds to define hypertension than previous guidelines. Little is known about the impact of these guideline changes in patients with or at high risk for cardiovascular disease. In this exploratory analysis using baseline blood pressure assessments in Systolic Blood Pressure Intervention Trial (SPRINT), we evaluated the prevalence and associated cardiovascular prognosis of patients newly reclassified with hypertension based on the 2017 ACC/AHA (systolic blood pressure ≥130 mm Hg or diastolic blood pressure ≥80 mm Hg) compared with the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation and Treatment of High Blood Pressure (JNC 7) guidelines (systolic blood pressure ≥140 mm Hg or diastolic blood pressure ≥90 mm Hg). The primary endpoint was the composite of myocardial infarction, other acute coronary syndromes, stroke, heart failure, or cardiovascular death. In 4683 patients assigned to the standard treatment arm of SPRINT, 2328 (49.7%) met hypertension thresholds by JNC 7 guidelines, and another 1424 (30.4%) were newly reclassified as having hypertension based on the 2017 ACC/AHA guidelines. Over 3.3-year median follow-up, 319 patients experienced the primary endpoint (87 of whom were newly reclassified with hypertension based on the revised guidelines). Patients with hypertension based on prior guidelines compared with those newly identified with hypertension based on the new guidelines had similar risk of the primary endpoint (2.3 [95% confidence interval {CI}, 2.0-2.7] vs 2.0 [95% CI, 1.6-2.4] events per 100 patient-years; adjusted HR, 1.10 [95% CI, 0.84-1.44]; P = .48). The 2017 ACC/AHA high blood pressure guidelines are expected to significantly increase the prevalence of patients with hypertension (perhaps to a greater extent in higher-risk patient cohorts compared with the general population) and

  4. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer].

    Science.gov (United States)

    Chen, X; Peng, D; Zhou, W; Zhong, Y

    1995-06-01

    To evaluate the accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer. 58 patients' (113 eyes) intraocular pressure were measured by Keeler, non-contact tonometer and R 900 Goldmann applanation tonometer and the results of measurement of intraocular pressure by the two kinds of tonometers were compared. The mean intraocular pressure measured by non-contact is 16.31 +/- 5.59 mmHg and 17.49 +/- 6.13 mmHg (1 mmHg = 0.1333 kPa) by Goldmann applanation tonometer, respectively. There was no statistical significance to be found (P > 0.05) between the two methods. By linear correlation and regression analysis, a positive correlation was found between the two methods (r = 0.8942, b = 0.8154). The handheld non-contact tonometer has the same accuracy and reliability of measurement of intraocular pressure comparing with Goldmann applanation tonometer, and it can be used in glaucoma clinic and screening.

  5. Elevated preoperative blood pressures in adult surgical patients are highly predictive of elevated home blood pressures.

    Science.gov (United States)

    Schonberger, Robert B; Nwozuzu, Adambeke; Zafar, Jill; Chen, Eric; Kigwana, Simon; Monteiro, Miriam M; Charchaflieh, Jean; Sophanphattana, Sophisa; Dai, Feng; Burg, Matthew M

    2018-04-01

    Blood pressure (BP) measurement during the presurgical assessment has been suggested as a way to improve longitudinal detection and treatment of hypertension. The relationship between BP measured during this assessment and home blood pressure (HBP), a better indicator of hypertension, is unknown. The purpose of the present study was to determine the positive predictive value of presurgical BP for predicting elevated HBP. We prospectively enrolled 200 patients at a presurgical evaluation clinic with clinic blood pressures (CBPs) ≥130/85 mm Hg, as measured using a previously validated automated upper-arm device (Welch Allyn Vital Sign Monitor 6000 Series), to undergo daily HBP monitoring (Omron Model BP742N) between the index clinic visit and their day of surgery. Elevated HBP was defined, per American Heart Association guidelines, as mean systolic HBP ≥135 mm Hg or mean diastolic HBP ≥85 mm Hg. Of the 200 participants, 188 (94%) returned their home blood pressure monitors with valid data. The median number of HBP recordings was 10 (interquartile range, 7-14). Presurgical CBP thresholds of 140/90, 150/95, and 160/100 mm Hg yielded positive predictive values (95% confidence interval) for elevated HBP of 84.1% (0.78-0.89), 87.5% (0.81-0.92), and 94.6% (0.87-0.99), respectively. In contrast, self-reported BP control, antihypertensive treatment, availability of primary care, and preoperative pain scores demonstrated poor agreement with elevated HBP. Elevated preoperative CBP is highly predictive of longitudinally elevated HBP. BP measurement during presurgical assessment may provide a way to improve longitudinal detection and treatment of hypertension. Copyright © 2018 American Heart Association. Published by Elsevier Inc. All rights reserved.

  6. Determination of Hg(2+) by on-line separation and pre-concentration with atmospheric-pressure solution-cathode glow discharge atomic emission spectrometry.

    Science.gov (United States)

    Li, Qing; Zhang, Zhen; Wang, Zheng

    2014-10-03

    A simple and sensitive method to determine Hg(2+) was developed by combining solution-cathode glow discharge atomic emission spectrometry (SCGD-AES) with flow injection (FI) based on on-line solid-phase extraction (SPE). We synthesized l-cysteine-modified mesoporous silica and packed it in an SPE microcolumn, which was experimentally determined to possess a good mercury adsorption capacity. An enrichment factor of 42 was achieved under optimized Hg(2+) elution conditions, namely, an FI flow rate of 2.0 mL min(-1) and an eluent comprised of 10% thiourea in 0.2 mol L(-1) HNO3. The detection limit of FI-SCGD-AES was determined to be 0.75 μg L(-1), and the precision of the 11 replicate Hg(2+) measurements was 0.86% at a concentration of 100 μg L(-1). The proposed method was validated by determining Hg(2+) in certified reference materials such as human hair (GBW09101b) and stream sediment (GBW07310). Copyright © 2014. Published by Elsevier B.V.

  7. Chronic binge alcohol consumption during pregnancy alters rat maternal uterine artery pressure response.

    Science.gov (United States)

    Naik, Vishal D; Lunde-Young, Emilie R; Davis-Anderson, Katie L; Orzabal, Marcus; Ivanov, Ivan; Ramadoss, Jayanth

    2016-11-01

    We aimed to investigate pressure-dependent maternal uterine artery responses and vessel remodeling following gestational binge alcohol exposure. Two groups of pregnant rats were used: the alcohol group (28.5% wt/v, 6.0 g/kg, once-daily orogastric gavage in a binge paradigm between gestational day (GD) 5-19) and pair-fed controls (isocalorically matched). On GD20, excised, pressurized primary uterine arteries were studied following equilibration (60 mm Hg) using dual chamber arteriograph. The uterine artery diameter stabilized at 20 mm Hg, showed passive distension at 40 mm Hg, and redeveloped tone at 60 mm Hg. An alcohol effect (P = 0.0025) was observed on the percent constriction of vessel diameter with greater pressure-dependent myogenic constriction. Similar alcohol effect was noted with lumen diameter response (P = 0.0020). The percent change in media:lumen ratio was higher in the alcohol group (P alcohol affects pressure-induced uterine artery reactivity, inward-hypotrophic remodeling, and adaptations critical for nutrient delivery to the fetus. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Evidence for the frequency-shift of the OA A_1g mode in Hg-based superconductors

    Science.gov (United States)

    Yang, In-Sang; Lee, Hye-Gyong

    1996-03-01

    The Hg-based superconductors, HgBa_2Ca_n-1Cu_nO_2n+2+δ (n=1,2,3) have two strong Raman peaks at ~ 570 and 590 cm-1 in the high-frequency region. From the results of Raman measurements of Tl-doped Hg-1223 system, it is concluded that the peak at ~ 570 cm-1 does not arise from the vibration of the interstitial oxygen O_δ in the Hg/Tl-O plane, but from the frequency-shift of the A_1g-type vibration of the apical oxygen O_A. The peak at 570 cm-1 is from the O_As surrounded by the O_δs in the nearest neighbor, while the 590 cm-1 mode is from the O_As without the O_δs in the immediate neighbor. The intensity of the 570 cm-1 mode increases with the O_δ content, but the Raman frequencies of both modes do not change significantly. This suggests that the increase of the frequency of the OA A_1g mode under high pressure (I.-S. Yang et al., Phys. Rev. B 51, 644 (1995)) is independent from the O_δ content, in the Hg-based superconductors.

  9. [Blood pressure in 6- to 45-month-old children. Apropos of a study of 264 children from nurseries].

    Science.gov (United States)

    Bérard, E; Boutté, P; Macone, F; Albertini, M; Mariani, R

    1988-03-01

    The systolic, diastolic and mean blood pressure and pulse rate were measured among 264 children aged 6 to 45 months, during routine check-up in 4 day-nurseries. We took the mean value of 3 successive measurements taken at one minute intervals on the upper arm of calm, asymptomatic children, with an automatic oscillometric monitor (Dinamap). When the mean systolic blood pressure was greater than 110 mmHg, the measurement was repeated. The results were related to weight, height and age and to personal and/or family history. The systolic pressure was steady with a 97th percentile at 110 mmHg. The diastolic pressure presented two levels: 97th percentile at 81 mmHg before 24 months and 73 mmHg afterwards. Nine children born to toxemic mothers, and 14 having required neonatal hospital care, had lower diastolic pressure. The other family or personal data were not linked to particular pressure groups.

  10. The difference in blood pressure readings between arms and survival: primary care cohort study.

    Science.gov (United States)

    Clark, Christopher E; Taylor, Rod S; Shore, Angela C; Campbell, John L

    2012-03-20

    To determine whether a difference in systolic blood pressure readings between arms can predict a reduced event free survival after 10 years. Cohort study. Rural general practice in Devon, United Kingdom. 230 people receiving treatment for hypertension in primary care. Bilateral blood pressure measurements recorded at three successive surgery attendances. Cardiovascular events and deaths from all causes during a median follow-up of 9.8 years. At recruitment 24% (55/230) of participants had a mean interarm difference in systolic blood pressure of 10 mm Hg or more and 9% (21/230) of 15 mm Hg or more; these differences were associated with an increased risk of all cause mortality (adjusted hazard ratio 3.6, 95% confidence interval 2.0 to 6.5 and 3.1, 1.6 to 6.0, respectively). The risk of death was also increased in 183 participants without pre-existing cardiovascular disease with an interarm difference in systolic blood pressure of 10 mm Hg or more or 15 mm Hg or more (2.6, 1.4 to 4.8 and 2.7, 1.3 to 5.4). An interarm difference in diastolic blood pressure of 10 mm Hg or more was weakly associated with an increased risk of cardiovascular events or death. Differences in systolic blood pressure between arms can predict an increased risk of cardiovascular events and all cause mortality over 10 years in people with hypertension. This difference could be a valuable indicator of increased cardiovascular risk. Bilateral blood pressure measurements should become a routine part of cardiovascular assessment in primary care.

  11. Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults.

    Science.gov (United States)

    Meng, Linghui; Zhao, Di; Pan, Yan; Ding, Wenqing; Wei, Qing; Li, Hua; Gao, Pingjin; Mi, Jie

    2016-01-13

    BACKGROUnD: To determine whether the professional Omron HBP-1300 blood pressure (BP) monitor meets American Association for the Advancement of Medical Instrumentation (AAMI) accuracy standards in Chinese children and adults. According to the AAMI protocol, simultaneous auscultatory measurements by two observers using a mercury manometer were obtained in participants using the Omron HBP-1300. Triple measurements were obtained after a minimum 5-min rest with a 1-min interval between adjacent measurements. A total of 85 participants submitted to 255 doctor-measured BP and 255 successful professional monitor readings. The initial auscultation systolic BP was 160 mmHg in seven participants (8.2%). All of the simultaneous measurements agreed to within ± 10 mmHg, while 95% agreed to within ± 4 mmHg for both systolic and diastolic BP, and the consistency between two observers was satisfactory. The difference between the devices was -1.3 ± 3.6 mmHg for systolic BP and 0.7 ± 3.8 mmHg for diastolic BP and by AAMI method 1, which met this guideline. The average difference between two devices by AAMI method 2 was 1.4 ± 3.2 mmHg for systolic BP and 1.0 ± 3.9 mmHg for diastolic BP, which met this guideline. The professional BP monitor Omron HBP-1300 is desirable for measuring the BP for Chinese children and adults.

  12. Relationship between chronic intermittent hypoxia and intraoperative mean arterial pressure in obstructive sleep apnea patients having laparoscopic bariatric surgery.

    Science.gov (United States)

    Turan, Alparslan; You, Jing; Egan, Cameron; Fu, Alex; Gazmuri, Ignazia; Khanna, Ashish; Eshraghi, Yashar; Ghosh, Raktim; Bose, Somnath; Qavi, Shahbaz; Arora, Lovkesh; Sessler, Daniel I; Doufas, Anthony G

    2015-01-01

    Recurrent nocturnal hypoxemia in obstructive sleep apnea enhances sympathetic function, decreases baroreceptor sensitivity, and weakens peripheral vascular responses to adrenergic signals. The authors hypothesized that the percentage of total sleep time spent at oxyhemoglobin saturation (SaO2) less than 90% and minimum nocturnal SaO2 on preoperative polysomnography are associated with decreased intraoperative mean arterial pressure. The authors examined the records of all patients who had laparoscopic bariatric surgery at Cleveland Clinic between 2005 and 2009 and an available polysomnography study. The authors assessed the relationships between the percentage of total sleep time spent at SaO2 less than 90% and minimum nocturnal SaO2, and the time-weighted average of mean arterial pressure. The authors used multivariable regression models to adjust for prespecified clinical confounders. Two hundred eighty-one patients were included in the analysis. The average change in the time-weighted average of mean arterial pressure was -0.02 (97.5% CI, -0.08, 0.04) mmHg for each 1% absolute increase in the percentage of sleep time spent at SaO2 less than 90% (P = 0.50). The average change was -0.13 (97.5% CI, -0.27, 0.01) mmHg, for each 1% absolute decrease in the minimum SaO2 (P = 0.04 > significance criterion of 0.025, Bonferroni correction). An unplanned analysis estimated 1% absolute decrease in minimum SaO2 was associated with -0.22 (98.75% CI, -0.39, -0.04) mmHg, change in mean arterial pressure (P = 0.002) in the time period between endotracheal intubation and trocar insertion. Recurrent nocturnal hypoxemia in obstructive sleep apnea is not a risk marker for intraoperative hypotension.

  13. Randomized trial of low versus high carbon dioxide insufflation pressures in posterior retroperitoneoscopic adrenalectomy.

    Science.gov (United States)

    Fraser, Sheila; Norlén, Olov; Bender, Kyle; Davidson, Joanne; Bajenov, Sonya; Fahey, David; Li, Shawn; Sidhu, Stan; Sywak, Mark

    2018-05-01

    Posterior retroperitoneoscopic adrenalectomy has gained widespread acceptance for the removal of benign adrenal tumors. Higher insufflation pressures using carbon dioxide (CO 2 ) are required, although the ideal starting pressure is unclear. This prospective, randomized, single-blinded, study aims to compare physiologic differences with 2 different CO 2 insufflation pressures during posterior retroperitoneoscopic adrenalectomy. Participants were randomly assigned to a starting insufflation pressure of 20 mm Hg (low pressure) or 25 mm Hg (high pressure). The primary outcome measure was partial pressure of arterial CO 2 at 60 minutes. Secondary outcomes included end-tidal CO 2 , arterial pH, blood pressure, and peak airway pressure. Breaches of protocol to change insufflation pressure were permitted if required and were recorded. A prospective randomized trial including 31 patients (low pressure: n = 16; high pressure: n = 15) was undertaken. At 60 minutes, the high pressure group had greater mean partial pressure of arterial CO 2 (64 vs 50 mm Hg, P = .003) and end-tidal CO 2 (54 vs 45 mm Hg, P = .008) and a lesser pH (7.21 vs 7.29, P = .0005). There were no significant differences in base excess, peak airway pressure, operative time, or duration of hospital stay. Clinically indicated protocol breaches were more common in the low pressure than the high pressure group (8 vs 3, P = .03). In posterior retroperitoneoscopic adrenalectomy, greater insufflation pressures are associated with greater partial pressure of arterial CO 2 and end-tidal CO 2 and lesser pH at 60 minutes, be significant. Commencing with lesser CO 2 insufflation pressures decreases intraoperative acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Interarm Difference in Blood Pressure: Reproducibility and Association with Peripheral Vascular Disease

    Directory of Open Access Journals (Sweden)

    Jesper Mehlsen

    2014-01-01

    Full Text Available The present study aimed at examining the interarm difference in blood pressure and its use as an indicator of peripheral arterial disease (PAD. Data were included from consecutive patients referred from their general practitioner to our vascular laboratory for possible PAD aged 50 years or older without known cardiac disease, renal disease, or diabetes mellitus. 824 patients (453 women with mean age of 72 years (range: 50–101 were included. 491 patients had a diagnosis of hypertension and peripheral arterial disease (PAD was present in 386 patients. Systolic blood pressure was 143 ± 24 mmHg and 142 ± 24 mmHg on the right and left arm, respectively (P=0.015. The interarm difference was greater in patients with hypertension (P=0.002 and PAD (P20 mmHg. This study confirmed the presence of a systematic but clinically insignificant difference in systolic blood pressure between arms. The interarm difference was larger in hypertension and PAD. Consistent lateralisation is present for differences ≥20 mmHg and an interarm difference >25 mmHg is a reliable indicator of PAD in the legs.

  15. Intracellular Hg(0) Oxidation in Desulfovibrio desulfuricans ND132.

    Science.gov (United States)

    Wang, Yuwei; Schaefer, Jeffra K; Mishra, Bhoopesh; Yee, Nathan

    2016-10-03

    The disposal of elemental mercury (Hg(0)) wastes in mining and manufacturing areas has caused serious soil and groundwater contamination issues. Under anoxic conditions, certain anaerobic bacteria can oxidize dissolved elemental mercury and convert the oxidized Hg to neurotoxic methylmercury. In this study, we conducted experiments with the Hg-methylating bacterium Desulfovibrio desulfuricans ND132 to elucidate the role of cellular thiols in anaerobic Hg(0) oxidation. The concentrations of cell-surface and intracellular thiols were measured, and specific fractions of D. desulfuricans ND132 were examined for Hg(0) oxidation activity and analyzed with extended X-ray absorption fine structure (EXAFS) spectroscopy. The experimental data indicate that intracellular thiol concentrations are approximately six times higher than those of the cell wall. Cells reacted with a thiol-blocking reagent were severely impaired in Hg(0) oxidation activity. Spheroplasts lacking cell walls rapidly oxidized Hg(0) to Hg(II), while cell wall fragments exhibited low reactivity toward Hg(0). EXAFS analysis of spheroplast samples revealed that multiple different forms of Hg-thiols are produced by the Hg(0) oxidation reaction and that the local coordination environment of the oxidized Hg changes with reaction time. The results of this study indicate that Hg(0) oxidation in D. desulfuricans ND132 is an intracellular process that occurs by reaction with thiol-containing molecules.

  16. Luminescent turn-on detection of Hg(II) via the quenching of an iridium(III) complex by Hg(II)-mediated silver nanoparticles.

    Science.gov (United States)

    Liu, Jinshui; Vellaisamy, Kasipandi; Yang, Guanjun; Leung, Chung-Hang; Ma, Dik-Lung

    2017-06-15

    A novel luminescent turn-on detection method for Hg(II) was developed. The method was based on the silver nanoparticle (AgNP)-mediated quenching of Ir(III) complex 1. The addition of Hg(II) ions causes the luminescence of complex 1 to be recovered due to the oxidation of AgNPs by Hg(II) ions to form Ag(I) and Ag/Hg amalgam. The luminescence intensity of 1 increased in accord with an increased Hg(II) concentration ranging from 0 nM to 180 nM, with the detection limit of 5 nM. This approach offers an innovative method for the quantification of Hg(II).

  17. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Science.gov (United States)

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  18. A novel, intelligent, pressure-sensing colostomy plug for reducing fecal leakage.

    Science.gov (United States)

    Chen, Fei; Li, Zhi-Chao; Li, Qiang; Liang, Fei-Xue; Guo, Xiong-Bo; Huang, Zong-Hai

    2015-06-01

    This study aims to describe and report the effectiveness of a novel, pressure-sensing colostomy plug for reducing fecal leakage. Nine miniature Tibetan pigs, aged 6-8 months, were given colostomies and divided into three groups (n = 3 each group). A novel pressure-sensing colostomy plug was placed in each pig and set to indicate when intestinal pressures of either 5, 10, or 15 mm Hg, respectively, were reached. When the pressure thresholds were reached, the animals' bowels were examined for the presence of stool and/or stomal leakage, and the data were recorded at weeks 1, 4, and 8 after surgery. The colostomy plug calibrated to 15 mm Hg pressure demonstrated the greatest accuracy in predicting the presence of stool in the bowels of study animals, averaging >90% sensitivity. In general, the sensitivity for predicting the presence of stool did not vary significantly over time, though there was a slight increase in accuracy in the 5 mm Hg group at later time-points. The sensitivity for predicting stool in the bowel did not change significantly over time in any of the three groups. Stomal leakage was found to be inversely proportional to the pressure-sensor setting, in that the 15 mm Hg group exhibited the greatest amount of leakage. This difference, however, was found to be significant only at week 1 postsurgery. The intelligent, pressure-sensing colostomy plug was able to accurately predict the presence of stool in the bowel and maintain continence, allowing negligible leakage. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. 40 CFR 60.4160 - Submission of Hg allowance transfers.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Submission of Hg allowance transfers... Times for Coal-Fired Electric Steam Generating Units Hg Allowance Transfers § 60.4160 Submission of Hg allowance transfers. An Hg authorized account representative seeking recordation of a Hg allowance transfer...

  20. Evaluation of the intraocular pressure measured with the ocular response analyzer.

    Science.gov (United States)

    Ogbuehi, Kelechi C; Almubrad, Turki M

    2010-07-01

    Comparison of the magnitude and repeatability of the intraocular pressure (IOP) measured with the Ocular Response Analyzer (ORA) to that measured with the Goldmann tonometer. Two sets of IOP measurements were made, for 89 eyes of eighty-nine subjects, approximately 1-week apart. Goldmann tonometry was performed subsequent to non-contact tonometry, in which the order of measurement was randomized between the ORA and the Topcon CT80 non-contact tonometer (CT80). Each method was assessed twice for intrasession repeatability. The limits of agreement between each non-contact pressure and that measured with the Goldmann tonometer were assessed once per session. The level of statistical significance was 0.05. The mean differences between the ORA-corneal compensated, Goldmann-correlated, and CT80-IOP (ORA-IOPcc; ORA-IOPg and CT80-IOP) versus the Goldmann IOP were -0.3 +/- 2.7 mmHg (mean +/- SD), -0.3 +/- 2.2 mmHg and -0.3 +/- 2.1 mmHg, respectively for session 1 and 0.3 +/- 3.0 mmHg, 0.2 +/- 2.2 mmHg, and -0.5 +/- 2.2 mmHg, respectively, for session 2. The repeatability coefficients were +/- 5.3 mmHg, +/- 4.2 mmHg, +/- 2.5 mmHg, and +/- 1.9 mmHg, respectively for ORA-IOPcc, ORA-IOPg, CT80-IOP, and Goldmann IOP in session 1 and +/- 3.8 mmHg, +/- 3.6 mmHg, +/- 1.6 mmHg, and +/- 1.9 mmHg, respectively for session 2. The repeatability indices for the ORA were poorer than those with the Goldmann tonometer and the CT80 in both sessions. However, the average IOP measured with the ORA did not vary significantly from those measured with the other two tonometers in either session. The ORA provides valid, repeatable measures of IOP.

  1. Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency

    Directory of Open Access Journals (Sweden)

    Jean B Kassem

    2015-01-01

    Full Text Available Ocular pulse amplitude (OPA is defined as the difference between maximum and minimum intraocular pressure (IOP during a cardiac cycle. Average values of OPA range from 1 to 4 mmHg. The purpose of this investigation is to determine the source of an irregular IOP waveform with elevated OPA in a 48-year-old male. Ocular pressure waveforms had an unusual shape consistent with early ventricular contraction. With a normal IOP, OPA was 9 mmHg, which is extraordinarily high. The subject was examined by a cardiologist and was determined to be in ventricular bigeminy. In addition, he had bounding carotid pulses and echocardiogram confirmed aortic insufficiency. After replacement of the aortic valve, the bigeminy resolved and the ocular pulse waveform became regular in appearance with an OPA of 1.6-2.0 mmHg. The ocular pressure waveform is a direct reflection of hemodynamics. Evaluating this waveform may provide an additional opportunity for screening subjects for cardiovascular anomalies and arrhythmias.

  2. Central venous pulse pressure analysis using an R-synchronized pressure measurement system.

    Science.gov (United States)

    Fujita, Yoshihisa; Hayashi, Daisuke; Wada, Shinya; Yoshioka, Naoki; Yasukawa, Takeshi; Pestel, Gunther

    2006-12-01

    The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

  3. Total mercury and methylmercury fluxes via emerging insects in recently flooded hydroelectric reservoirs and a natural lake

    International Nuclear Information System (INIS)

    Tremblay, Alain; Lucotte, Marc; Cloutier, Louise

    1998-01-01

    Total mercury (total Hg) concentrations in emerging aquatic insects ranged from 140 to 1500 ng g -1 dry wt. in two hydroelectric reservoirs of northern Quebec compared with 50-160 ng g -1 dry wt. in a natural lake. Methylmercury (MeHg) concentrations were somewhat lower, ranging from 35 to 800 ng Hg g -1 dry wt. in reservoirs and from 29 to 90 ng g -1 dry wt. in the natural lake. Contamination of insect taxa of reservoirs was on average 2-3 times higher than their counterparts in the natural lake. There was no difference between total Hg and MeHg concentrations of insects sampled from flooded forest soils and flooded peatland, although total Hg and MeHg concentrations differed between flooded peatland and flooded forest soils themselves. Insect biomasses were approx. two times higher in the reservoirs than in the natural lake (580-2200 mg m -2 year -1 dry wt., 950 mg m -2 year -1 dry wt., respectively); chironomids dominated in the reservoirs and trichopterans dominated in the natural lake. Similarly, total MeHg fluxes via emerging insects were approx. 2-4 times higher in reservoirs than that of the natural lake (55-224 ng MeHg m -2 year -1 dry wt., 74 ng MeHg m -2 year -1 dry wt., respectively). Our results show the importance of the insect community in the transfer of MeHg from flooded soils and flooded peatlands to fish, and that this pathway probably makes a significant contribution to the rapid rise of Hg levels in the fish community after flooding

  4. Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.

    Science.gov (United States)

    Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe

    2017-07-01

    After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.

  5. Coulomb excitation of 206Hg at relativistic energies

    Science.gov (United States)

    Alexander, Tom

    The region of the nuclear chart surrounding the doubly-magic nucleus 208Pb provides a key area to constrain and develop contemporary nuclear structure models. One aspect of particular interest is the transition strength of the first excited 2+ state in even-even nuclei; this work describes the measurement of this value for the case of 206Hg, where the Z=80 line meets the N=126 shell closure. The nuclei of interest were synthesized using relativistic-energy projectile fragmentation at the GSI facility in Germany. They were produced in the fragmentation of a primary 208Pb beam at an energy of 1 GeV per nucleon, and separated and identifed using the Fragment Separator. The secondary beams with an energy of 140 MeV per nucleon were Coulomb excited on a secondary target of 400 mg/cm. 2 gold. Gamma-rays were detected with the Advanced GAmma Tracking Array (AGATA). The precise scattering angle for Doppler-correction was determined with position information from the Lund-York-Cologne-CAlorimeter(LYCCA). Using the sophisticated tracking algorithm native to AGATA in conjunction with pulse-shape analysis, a precise Doppler-correction is performed on the gamma spectra, and using a complex n-dimensional analysis, the B(E2) value for 206Hg is extracted relative to the known value also measured in 206Pb. A total of 409 million 206Hg particles were measured, and a cross-section of 50 mb was determined for the 2+ state at 1068 keV. The measurement of the B(E2) transition strength was found to be 1.109 W.u. This result is compared to a number of theoretical calculations, including two Gogny forces, and a modified shell model parametrization and is found to be smaller than all calculated estimations, implying that the first excited 2. + state in . {206}Hg is uncollective in nature.

  6. Does aqueductal stenosis influence the lumbar infusion test in normal-pressure hydrocephalus?

    Science.gov (United States)

    González-Martínez, Emilio Luis; Santamarta, David

    2016-12-01

    Late-onset idiopathic aqueductal stenosis may present with clinical features indistinct from idiopathic normal-pressure hydrocephalus (NPH). Moreover, aqueductal stenosis (AS) is not always detected by conventional magnetic resonance imaging (MRI). The aim of this study was to compare the hydrodynamic pattern among NPH patients according to the patency of the aqueduct. Fifty-six consecutive lumbar infusion tests were performed in patients with NPH syndrome. Precipitating causes of hydrocephalus were excluded, and aqueductal patency was examined through high-resolution, T2-weighted 3D MRI. Patients were classified into two groups: non-patent aqueduct and patent aqueduct. Mean values of pressure and pulse amplitude were obtained from basal and plateau stages of infusion studies. Twelve of 56 patients with NPH-like symptoms presented with morphological AS (21.4 %). Patent aqueduct and non-patent aqueduct groups had similar values of mean opening lumbar pressure (8.2 vs. 8.1 mmHg), and mean opening pulse amplitude (3.1 vs. 2.9 mmHg). Mean pressure in the plateau stage (28.6 vs. 23.2 mmHg), and mean pulse amplitude in the plateau stage (12.5 vs. 10.6 mmHg) were higher in the patent aqueduct group. These differences were not statistically significant. Only Rout was significantly higher in the patent aqueduct group (13.6 vs. 10.1 mmHg/ml/min). One-third of NPH patients with AS presented Rout >12 mmHg/ml/min. No differences in mean pressure or pulse amplitude during basal and plateau epochs of the lumbar infusion test in NPH patients were detected, regardless of aqueductal patency. However, Rout was significantly higher in patients with patent aqueduct.

  7. Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Sunagawa, Gengo; Horvath, David J; Byram, Nicole; Kuban, Barry D; Dessoffy, Raymond; Sale, Shiva; Golding, Leonard A R; Moazami, Nader

    2017-12-01

    The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) on hemodynamics and pump flow in an awake chronic calf model. The sinusoidal pump speed modulations, performed on the day of elective sacrifice, were set at ±15 and ± 25% of mean pump speed at 80 bpm in four awake calves with a CFTAH. The systemic and pulmonary arterial pulse pressures increased to 12.0 and 12.3 mmHg (±15% modulation) and to 15.9 and 15.7 mmHg (±25% modulation), respectively. The pulsatility index and surplus hemodynamic energy significantly increased, respectively, to 1.05 and 1346 ergs/cm at ±15% speed modulation and to 1.51 and 3381 ergs/cm at ±25% speed modulation. This study showed that it is feasible to generate pressure pulsatility with pump speed modulation; the platform is suitable for evaluating the physiologic impact of pulsatility and allows determination of the best speed modulations in terms of magnitude, frequency, and profiles.

  8. Low Pressure Robot-assisted Radical Prostatectomy With the AirSeal System at OLV Hospital: Results From a Prospective Study.

    Science.gov (United States)

    La Falce, Sabrina; Novara, Giacomo; Gandaglia, Giorgio; Umari, Paolo; De Naeyer, Geert; D'Hondt, Frederiek; Beresian, Jean; Carette, Rik; Penicka, Martin; Mo, Yujiing; Vandenbroucke, Geert; Mottrie, Alexandre

    2017-12-01

    Limited studies examined effects of pneumoperiotneum during robot-assisted radical prostatectomy (RARP) and with AirSeal. The aim of this study was to assess the effect on hemodynamics of a lower pressure pneumoperitoneum (8 mmHg) with AirSeal, during RARP in steep Trendelenburg 45° (ST). This is an institutional review board-approved, prospective, interventional, single-center study including patients treated with RARP at OLV Hospital by one extremely experienced surgeon (July 2015-February 2016). Intraoperative monitoring included: arterial pressure, central venous pressure, cardiac output, heart rate, stroke volume, systemic vascular resistance, intrathoracic pressure, airways pressures, left ventricular end-diastolic and end-systolic areas/volumes and ejection fraction, by transesophageal echocardiography, an esophageal catheter, and FloTrac/Vigileo system. Measurements were performed after induction of anesthesia with patient in horizontal (T0), 5 minutes after 8 mmHg pneumoperitoneum (TP), 5 minutes after ST (TT1) and every 30 minutes thereafter until the end of surgery (TH). Parameters modification at the prespecified times was assessed by Wilcoxon and Friedman tests, as appropriate. All analyses were performed by SPSS v. 23.0. A total of 53 consecutive patients were enrolled. The mean patients age was 62.6 ± 6.9 years. Comorbidity was relatively limited (51% with Charlson Comorbidity Index as low as 0). Despite the ST, working always at 8 mmHg with AirSeal, only central venous pressure and mean airways pressure showed a statistically significant variation during the operative time. Although other significant hemodynamic/respiratory changes were observed adding pneumoperitoneum and then ST, all variables remained always within limits safely manageable by anesthesiologists. The combination of ST, lower pressure pneumoperitoneum and extreme surgeon's experience enables to safely perform RARP. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Differential determination of 203Hg and 14C or 35S in double labelled biological samples

    International Nuclear Information System (INIS)

    Bem, E.M.; Bem, H.; Reimschussel, W.

    1979-01-01

    The differential determination of 203 Hg and 14 C or 35 S in double labelled biological samples is presented. The biological samples were mineralized with 70% HClO 4 and 30% H 2 O 2 in glass vials, MILLI-6. The γ-activity of 203 Hg was measured on a well scintillation counter. The total activity, due to 203 Hg and 14 C or 35 S, was measured by the liquid scintillation technique after addition of Aquasol into the same vials. The method of external standard channel ratio was used for standardization. Very good recoveries were obtained: 100+-0.7% for 203 Hg and 94.6-101.0% for 14 C and 35 S. This method could be used for other β, γ and β-active nuclides with similar β-spectra. (author)

  10. Immobilization of aqueous Hg(II) by mackinawite (FeS)

    International Nuclear Information System (INIS)

    Liu Jianrong; Valsaraj, Kalliat T.; Devai, Istvan; DeLaune, R.D.

    2008-01-01

    As one of the major constituents of acid volatile sulfide (AVS) in anoxic sediments, mackinawite (FeS) is known for its ability to scavenge trace metals. The interaction between aqueous Hg(II) (added as HgCl 2 ) and synthetic FeS was studied via batch sorption experiments conducted under anaerobic conditions. Due to the release of H + during formation of hydrolyzed Hg(II) species which is more reactive than Hg 2+ in surface adsorption, the equilibrium pH decreased with the increase in Hg(II)/FeS molar ratio. Counteracting the loss of FeS solids at lower pH, the maximum capacity for FeS to remove aqueous Hg(II) was approximately 0.75 mol Hg(II) (mol FeS) -1 . The comparison of X-ray power diffraction (XRPD) patterns of synthetic FeS sorbent before and after sorption showed that the major products formed from the interaction between FeS and the aqueous Hg(II) were metacinnabar, cinnabar, and mercury iron sulfides. With the addition of FeS at 0.4 g L -1 to a 1 mM Hg(II) solution with an initial pH of 5.6, Fe 2+ release was approximately 0.77 mol Fe 2+ per mol Hg(II) removed, suggesting that 77% of Hg(II) was removed via precipitation reaction under these conditions, with 23% of Hg(II) removed by adsorption. Aeration does not cause significant release of Hg(II) into the water phase

  11. Centennial record of anthropogenic impacts in Galveston Bay: Evidence from trace metals (Hg, Pb, Ni, Zn) and lignin oxidation products.

    Science.gov (United States)

    Al Mukaimi, Mohammad E; Kaiser, Karl; Williams, Joshua R; Dellapenna, Timothy M; Louchouarn, Patrick; Santschi, Peter H

    2018-06-01

    During the 20th century the impacts of industrialization and urbanization in Galveston Bay resulted in significant shifts in trace metals (Hg, Pb, Ni, Zn) and vascular plant biomarkers (lignin phenols) recorded within the surface sediments and sediment cores profile. A total of 22 sediment cores were collected in Galveston Bay in order to reconstruct the historical input of Hg, Pb, Ni, Zn and terrestrial organic matter. Total Hg (T-Hg) concentration ranged between 6 and 162 ng g -1 in surface sediments, and showed decreasing concentrations southward from the Houston Ship Channel (HSC) toward the open estuary. Core profiles of T-Hg and trace metals (Ni, Zn) showed substantial inputs starting in 1905, with peak concentrations between 1960 and 1970's, and decreasing thereafter with exception to Pb, which peaked around 1930-1940s. Stable carbon isotopes and lignin phenols showed an increasing input of terrestrial organic matter driven by urban development within the watershed in the early 1940s. Both the enrichment factor and the geoaccumulation index (I geo ) for T-Hg as a measure of the effectiveness of environmental management practices showed substantial improvements since the 1970s. The natural recovery rate in Galveston Bay since the peak input of T-Hg was non-linear and displayed a slow recovery during the twenty-first century. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Effect of self-monitoring and medication self-titration on systolic blood pressure in hypertensive patients at high risk of cardiovascular disease: the TASMIN-SR randomized clinical trial.

    Science.gov (United States)

    McManus, Richard J; Mant, Jonathan; Haque, M Sayeed; Bray, Emma P; Bryan, Stirling; Greenfield, Sheila M; Jones, Miren I; Jowett, Sue; Little, Paul; Penaloza, Cristina; Schwartz, Claire; Shackleford, Helen; Shovelton, Claire; Varghese, Jinu; Williams, Bryan; Hobbs, F D Richard; Gooding, Trevor; Morrey, Ian; Fisher, Crispin; Buckley, David

    2014-08-27

    Self-monitoring of blood pressure with self-titration of antihypertensives (self-management) results in lower blood pressure in patients with hypertension, but there are no data about patients in high-risk groups. To determine the effect of self-monitoring with self-titration of antihypertensive medication compared with usual care on systolic blood pressure among patients with cardiovascular disease, diabetes, or chronic kidney disease. A primary care, unblinded, randomized clinical trial involving 552 patients who were aged at least 35 years with a history of stroke, coronary heart disease, diabetes, or chronic kidney disease and with baseline blood pressure of at least 130/80 mm Hg being treated at 59 UK primary care practices was conducted between March 2011 and January 2013. Self-monitoring of blood pressure combined with an individualized self-titration algorithm. During the study period, the office visit blood pressure measurement target was 130/80 mm Hg and the home measurement target was 120/75 mm Hg. Control patients received usual care consisting of seeing their health care clinician for routine blood pressure measurement and adjustment of medication if necessary. The primary outcome was the difference in systolic blood pressure between intervention and control groups at the 12-month office visit. Primary outcome data were available from 450 patients (81%). The mean baseline blood pressure was 143.1/80.5 mm Hg in the intervention group and 143.6/79.5 mm Hg in the control group. After 12 months, the mean blood pressure had decreased to 128.2/73.8 mm Hg in the intervention group and to 137.8/76.3 mm Hg in the control group, a difference of 9.2 mm Hg (95% CI, 5.7-12.7) in systolic and 3.4 mm Hg (95% CI, 1.8-5.0) in diastolic blood pressure following correction for baseline blood pressure. Multiple imputation for missing values gave similar results: the mean baseline was 143.5/80.2 mm Hg in the intervention group vs 144.2/79.9 mm Hg in the control group, and

  13. Total dose radiation effects of pressure sensors fabricated on uni-bond-SOI materials

    International Nuclear Information System (INIS)

    Zhu Shiyang; Huang Yiping; Wang Jin; Li Anzhen; Shen Shaoqun; Bao Minhang

    2001-01-01

    Piezoresistive pressure sensors with a twin-island structure were successfully fabricated using high quality Uni-bond-SOI (On Insulator) materials. Since the piezoresistors were structured by the single crystalline silicon overlayer of the SOI wafer and were totally isolated by the buried SiO 2 , the sensors are radiation-hard. The sensitivity and the linearity of the pressure sensors keep their original values after being irradiated by 60 Co γ-rays up to 2.3 x 10 4 Gy(H 2 O). However, the offset voltage of the sensor has a slight drift, increasing with the radiation dose. The absolute value of the offset voltage deviation depends on the pressure sensor itself. For comparison, corresponding polysilicon pressure sensors were fabricated using the similar process and irradiated at the same condition

  14. Injury of Hg2+ and DBS on Lemna minor%Hg2+、DBS对浮萍的伤害研究

    Institute of Scientific and Technical Information of China (English)

    马剑敏; 王琳; 杜晋立; 吴晶敏

    2001-01-01

    The injury degree of Lemna minor by the stress of Hg2+ and DBSare reported.The concentrations of chlorophyll and dissolved protein decrease with the increase of Hg2+ and DBS concentrations or as treatment time is continued,dead percentage increase with the increase of Hg2+ and DBS concentrations or as treatment time is continued.When the concentrations of HgCl2 is 6mg/L or DBS is 12mg/L,about 70% of Lemna minor can live for 10 days at least.%研究了在Hg2+、DBS胁迫下,浮萍(LemnaminorL.)植株的枯死率、叶绿素含量和可溶性蛋白质含量的变化。植株的枯死率随Hg2+、DBS浓度升高和处理时间的延长而增加;叶绿素和蛋白质含量随Hg2+和DBS浓度升高和处理时间的延长而逐渐下降。在HgCl2、DBS浓度分别为6mg/L、12mg/L时,约70%的浮萍10d内仍存活。

  15. Do other cardiovascular risk factors influence the impact of age on the association between blood pressure and mortality?

    DEFF Research Database (Denmark)

    Vishram, Julie K K; Borglykke, Anders; Andreasen, Anne H

    2014-01-01

    Hg increase in SBP/DBP by multivariate-adjusted Cox regressions, including SBP and DBP simultaneously. Because of nonlinearity, SBP and DBP were analyzed separately for blood pressure (BP) values above and below a cut-point wherein mortality risk was the lowest. For the total population, significantly...... 82 mmHg [1.03 (1.02-1.05)]. BP values below the cut-points were inversely related to mortality risk. Taking into account the age × BP interaction, there was a gradual shift from DBP (19-26 years) to both DBP and SBP (27-62 years) and to SBP (63-78 years) as risk factors for stroke mortality and all...

  16. The influence of Parachlorella beyerinckii CK-5 on the absorption and excretion of methylmercury (MeHg) in mice.

    Science.gov (United States)

    Uchikawa, Takuya; Yasutake, Akira; Kumamoto, Yoshimitsu; Maruyama, Isao; Kumamoto, Shoichiro; Ando, Yotaro

    2010-02-01

    Chlorella (Parachlorella beyerinckii CK-5), previously identified as Chlorella vulgaris CK-5, is a unicellular green algae that has for many years been used as a nutritional supplement. In order to investigate the effects of methylmercury (MeHg) detoxification by Chlorella, we examined the absorption and excretion of MeHg in mice. Female C57BL/6N mice were randomly divided into three groups of five, and were housed in metabolism cages. Mice were orally administered MeHg chloride at doses of 5 mg (4 mg Hg)/kg body weight with or without 100 mg/mouse of P. beyerinckii powder (BP), and were assigned to either a MeHg group or MeHg + BP group, accordingly. Twenty-four hr after oral administration, feces and urine were collected, and blood, liver, and kidney samples were obtained. Total mercury contents in the samples obtained were determined using an atomic absorption method. The amounts of Hg excreted in feces and urine of the MeHg + BP group were increased nearly 1.9 and 2.2-fold compared with those of the MeHg group. On the other hand, blood and organ Hg levels were not significantly different between two groups. These results suggest that the intake of BP may induce the excretion of Hg both in feces and urine, although it does not affect MeHg absorption from the gastrointestinal tract. The effect of BP on the tissue mercury accumulation may become evident in a long-term experiment.

  17. Two zero-flow pressure intercepts exist in autoregulating isolated skeletal muscle.

    Science.gov (United States)

    Braakman, R; Sipkema, P; Westerhof, N

    1990-06-01

    The autoregulating vascular bed of the isolated canine extensor digitorum longus muscle was investigated for the possible existence of two positive zero-flow pressure axis intercepts, a tone-dependent one and a tone-independent one. An isolated preparation, perfused with autologous blood, was used to exclude effects of collateral flow and nervous and humoral regulation while autoregulation was left intact [mean autoregulatory gain 0.50 +/- 0.24 (SD)]. In a first series of experiments, the steady-state (zero flow) pressure axis intercept [mean 8.9 +/- 2.6 (SD) mmHg, tone independent] and the instantaneous (zero flow) pressure axis intercept [mean 28.5 +/- 9.9 (SD) mmHg, tone dependent] were determined as a function of venous pressure (range: 0-45 mmHg) and were independent of venous pressure until the venous pressure exceeded their respective values. Beyond this point the relations between the venous pressure and the steady-state and instantaneous pressure axis intercept followed the line of identity. The findings agree with the predictions of the vascular waterfall model. In a second series it was shown by means of administration of vasoactive drugs that the instantaneous pressure axis intercept is tone dependent, whereas the steady-state pressure axis intercept is not. It is concluded that there is a (proximal) tone-dependent zero-flow pressure at the arteriolar level and a (distal) tone-independent zero-flow pressure at the venous level.

  18. Variation with Mach Number of Static and Total Pressures Through Various Screens

    Science.gov (United States)

    Adler, Alfred A

    1946-01-01

    Tests were conducted in the Langley 24-inch highspeed tunnel to ascertain the static-pressure and total-pressure losses through screens ranging in mesh from 3 to 12 wires per inch and in wire diameter from 0.023 to 0.041 inch. Data were obtained from a Mach number of approximately 0.20 up to the maximum (choking) Mach number obtainable for each screen. The results of this investigation indicate that the pressure losses increase with increasing Mach number until the choking Mach number, which can be computed, is reached. Since choking imposes a restriction on the mass rate of flow and maximum losses are incurred at this condition, great care must be taken in selecting the screen mesh and wire dimmeter for an installation so that the choking Mach number is

  19. Fourier transform nuclear magnetic resonance studies of 199Hg

    International Nuclear Information System (INIS)

    Krueger, H.; Lutz, O.; Nolle, A.; Schwenk, A.

    1975-01-01

    199 Hg Fourier Transform NMR studies of various solutions of diverse mercury salts in H 2 O and D 2 O or in the appropriate protonated and deuterated acids are reported for both Hg 2 ++ and Hg ++ . In the different solutions investigated the 199 Hg line positions depend on the concentration of the solution, on the solvents and their isotopic composition and on the temperature of the sample. A ratio of the Larmor frequency of 199 Hg and of 2 H in a Hg(NO 3 ) 2 solution in dilute DNO 3 is given. Using this ratio and the measured chemical shifts, a ratio of the Larmor frequencies of 199 Hg for infinite dilution relative to 2 H in pure D 2 O is given. From this a g 1 -factor for 199 Hg is derived and compared with the g 1 -factor of an optical pumping experiment. The resulting shielding constant is sigma (hydrated 199 Hg ++ versus 199 Hg atom) = -24.32(5) x 10 -4 . This yields an atomic reference scale for all measured NMR line shifts of mercury. (orig.) [de

  20. The impact of renal artery stent revascularization on blood pressure: 1-year follow-up of 110 cases

    International Nuclear Information System (INIS)

    Wang Chao; Zou Yinghua; Yang Min; Wang Jian; Tong Xiaoqiang; Song Li

    2007-01-01

    Objective: To investigate the effect of renal artery revascularization through renal artery stenting(PTRAS)on blood pressure in patients with renal artery stenosis. Methods: During April 2000 through May 2005 110 cases of renal artery stenosis received PTRAS and followed up for at least 1 year with blood pressure measurements pre-and 1 year post-PTRAS. Results: The technical success rate was 100% for all 110 cases. The renal artery stenosis were decreased from 60%-100% before PTRAS to 0%-15% after the stent placement. There was significant difference between blood pressure pre-and 1 year post PTRAS. Systolic pressures decreased from(153 ± 32) mmHg to(131 ± 27) mmHg and diastolic pressures from(87 ± 19) mmHg to(75 ± 19) mmHg. The administration of antihypertensive diugs reduced from(2.6 ± 0.9 ) sorts to(1.9 ± 0.9) sorts. Conclusions: PTRAS revascularization is an effective procedure for blood pressure control in renal vascular hypertension during one year follow up. (authors)

  1. Mid-regional pro-atrial natriuretic peptide and blood pressure in adolescents

    DEFF Research Database (Denmark)

    Goharian, Tina S; Gimsing, Anders N; Goetze, Jens P

    2015-01-01

    Little is known about blood pressure in relation to circulating natriuretic peptide concentrations and gender in generally healthy adolescents. We studied 15-year-old females and males (n = 335) from the Danish site of the European Youth Heart Study (EYHS). Blood pressure was measured using...... a standardized protocol, sexual maturity was assessed according to Tanner stage, and as a surrogate for atrial natriuretic peptide, we measured mid-regional pro-atrial natriuretic peptide (MR-proANP) in plasma. Compared with boys, girls had lower systolic blood pressure (SBP) (mean ± SD: 109.6 ± 9.9 mmHg vs 116.......9 ± 11.4 mmHg, p blood pressure...

  2. Assessing Optimal Blood Pressure in Patients With Asymptomatic Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Nielsen, Olav W; Sajadieh, Ahmad; Sabbah, Muhammad

    2016-01-01

    BACKGROUND: Evidence for treating hypertension in patients with asymptomatic aortic valve stenosis is scarce. We used data from the SEAS trial (Simvastatin Ezetimibe in Aortic Stenosis) to assess what blood pressure (BP) would be optimal. METHODS: A total of 1767 patients with asymptomatic aortic...... stenosis and no manifest atherosclerotic disease were analyzed. Outcomes were all-cause mortality, cardiovascular death, heart failure, stroke, myocardial infarction, and aortic valve replacement. BP was analyzed in Cox models as the cumulative average of serially measured BP and a time-varying covariate.......039). CONCLUSIONS: Optimal BP seems to be systolic BP of 130 to 139 mm Hg and diastolic BP of 70 to 90 mm Hg in these patients with asymptomatic aortic stenosis and no manifest atherosclerotic disease or diabetes mellitus. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT...

  3. Analysis of As, Cr and Hg in crude oil sludge by using instrumental neutron activation analysis (INAA)

    International Nuclear Information System (INIS)

    Syazwani Mohd Fadzil; Khoo Kok Sionga, Amran Ab Majid; Sukiman Sarmani

    2009-01-01

    Environment are carrying toxic elements. The aim of this study was to determine As, Cr and Hg elements in crude oil sludge. In this study, crude oil sludge samples from a refining plant at Kerteh, Terengganu was carried out using Instrumental Neutron Activation Analysis (INAA). The samples were packed and irradiated at the Malaysian Nuclear Agency reactor TRIGA Mark II. Later, the samples were counted using a HPGe detector and were analyzed using the SAMPO 90 software. The certified reference material (CRM) namely NBS Coal Fly Ash 1633a was used as a standard to obtain the concentration average using a comparative method. A total of 11 elements (i.e. As, Co, Cr, Fe, Ga, Hg, Mn, Na, Sc, Se and Sr) were determined in all samples. The concentrations of As, Cr and Hg were found to be in the range of 0-18.8, 98.2-124 and 52.8-57.9 μg.g -1 respectively. From the concentration of these elements, the results showed that the value for total As element is low but the values for the total Cr and Hg are considerable higher than the permissible value. However, almost all the potential environmental impacts can be controlled by sludge disposal options such as well-designed, carefully, efficiently and continuously managed, by following accepted guidelines and regulations. (Author)

  4. Evaluation of the effect of systolic blood pressure and pulse pressure on cognitive function: the Women's Health and Aging Study II.

    Directory of Open Access Journals (Sweden)

    Sevil Yasar

    Full Text Available Evidence suggests that elevated systolic blood pressure (SBP and pulse pressure (PP in midlife is associated with increased risk for cognitive impairment later in life. There is mixed evidence regarding the effects of late life elevated SBP or PP on cognitive function, and limited information on the role of female gender.Effects of SBPand PPon cognitive abilities at baseline and over a 9-year period were evaluated in 337 non-demented community-dwelling female participants over age 70 in the Women's Health and Aging Study II using logistic and Cox proportional hazards regression analyses. Participants aged 76-80 years with SBP≥160 mmHg or PP≥84 mmHg showed increased incidence of impairment on Trail Making Test-Part B (TMT, Part B, a measure of executive function, over time when compared to the control group that included participants with normal and pre-hypertensive SBP (<120 and 120-139 mmHg or participants with low PP (<68 mmHg (HR = 5.05 [95%CI = 1.42, 18.04], [HR = 5.12 [95%CI = 1.11; 23.62], respectively. Participants aged 70-75 years with PP≥71 mmHg had at least a two-fold higher incidence of impairment on HVLT-I, a measure of verbal learning, over time when compared to participants with low PP (<68 mmHg (HR = 2.44 [95%CI = 1.11, 5.39].Our data suggest that elevated SBP or PP in older non-demented women increases risk for late-life cognitive impairment and that PP could be used when assessing the risk for impairment in cognitive abilities. These results warrant further, larger studies to evaluate possible effects of elevated blood pressure in normal cognitive aging.

  5. Blood pressure responses to LBNP in nontrained and trained hypertensive rats

    Science.gov (United States)

    Bedford, T. G.; Tipton, C. M.

    1992-01-01

    To study the influences of 16 wk of endurance training on the reflex regulation of resting blood pressure, nontrained (NT) and trained (T) female hypertensive rats (SHR) were subjected to conditions of lower body negative pressure (LBNP). Measurements of muscle cytochrome oxidase activity and run time to exhaustion indicated that the animals were endurance trained. The rats (NT = 6, T = 7) were tranquilized with 300-600 micrograms.kg-1 diazepam (IV) before heart rates and blood pressures were measured over a range of 2.5-10.0 mm Hg of negative pressure. When subjected to conditions of LBNP, the reflex tachycardia of the T group was greater than the NT at the lower (-2.5 and -5.0 mm Hg) negative pressures. Although arterial pressure declines were similar in both groups, the T group experienced significantly less of a decline in central venous pressure than the NT animals. When chlorisondamine was used as a ganglionic blocker (2.5 mg.kg-1, IV), the fall in CVP at 10 mm Hg negative pressure was greater for the NT group while the fall in the initial systemic arterial pressure was more for the T group. From these results we concluded that training had altered the interaction between cardiopulmonary and arterial baroreflexes in these hypertensive rats and a nonneural component had been altered such as cardiac function.

  6. Design and synthesis of BODIPY-clickate based Hg(2+) sensors: the effect of triazole binding mode with Hg(2+) on signal transduction.

    Science.gov (United States)

    Vedamalai, Mani; Kedaria, Dhaval; Vasita, Rajesh; Mori, Shigeki; Gupta, Iti

    2016-02-14

    BODIPY-clickates, F1 and F2, for the detection of Hg(2+) have been designed, synthesized and characterized. Both F1 and F2 showed hyperchromic shifts in the UV-visible spectra in response to increasing Hg(2+) concentrations. Hg(2+) ion binding caused perturbation of the emission quenching process and chelation induced enhanced bathochromic emission of F1 and F2 to 620 nm and 660 nm, respectively. Job's plot clearly indicated that the binding ratio of F1 and F2 with Hg(2+) was 1 : 1. The NMR titration of BODIPY-clickates with Hg(2+) confirmed that aromatic amines and triazoles were involved in the binding event. Furthermore, HRMS data of F1-Hg(2+) and F2-Hg(2+) supported the formation of mercury complexes of BODIPY-clickates. The dissociation constant for the interaction between fluorescent probes F1 and F2 with Hg(2+) was found to be 24.4 ± 5.1 μM and 22.0 ± 3.9 μM, respectively. The Hg(2+) ion induced fluorescence enhancement was almost stable in a pH range of 5 to 8. Having less toxicity to live cells, both the probes were successfully used to map the Hg(2+) ions in live A549 cells.

  7. HPLC-HG-AFS determination of arsenic species in acute promyelocytic leukemia (APL) plasma and blood cells.

    Science.gov (United States)

    Guo, Meihua; Wang, Wenjing; Hai, Xin; Zhou, Jin

    2017-10-25

    Arsenic trioxide (ATO) has been successfully used in the treatment of acute promyelocytic leukemia (APL). To clarify the arsenic species in APL patients, high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry (HPLC-HG-AFS) and HG-AFS methods were developed and validated to quantify the plasma concentrations of inorganic arsenic (As(III) and As(V)) and methylated metabolites (MMA and DMA), and the total amounts of arsenic in blood cells and plasma. Blood cells and plasma were digested with mixtures of HNO 3 H 2 O 2 and analyzed by HG-AFS. For arsenic speciation, plasma samples were prepared with perchloric acid to precipitate protein. The supernatant was separated on an anion-exchange column within 6min with isocratic elution using 13mM CH 3 COONa, 3mM NaH 2 PO 4 , 4mM KNO 3 and 0.2mM EDTA-2Na. The methods provided linearity range of 0.2-20ng/mL for total arsenic and 2.0-50ng/mL for four arsenic species. The developed methods for total arsenic and arsenic species determination were precise and accurate. The spiked recoveries ranged from 81.2%-108.6% and the coefficients of variation for intra- and inter-batch precision were less than 9.3% and 12.5%, respectively. The developed methods were applied successfully for the assay of total arsenic and arsenic species in 5 APL patients. The HPLC-HG-AFS may be a good alternative for arsenic species determination in APL patients with its simplicity and low-cost in comparison with HPLC-ICP-MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Review : Pressure Ulcer and Its treatment

    OpenAIRE

    Bijan Khorasani; Ali Ghafouri

    2004-01-01

    Pressure ulcer is a signifcant problem in elderly and critically ill patients, causing pain, decreasing quality of life and leading to prolonged hospital stay. Treatment of pressure ulcer to improve health status is a cost-effective approach. So, preventing the ulcers will be economical. Pressure ulcer is considered as a damage or necrosis of skin and its layers, which happens when there is a considerable pressure over the tissues. If the capillary arterie's pressure reaches 70 mmHg (2 ti...

  9. Hg isotopes reveal in-stream processing and legacy inputs in East Fork Poplar Creek, Oak Ridge, Tennessee, USA.

    Science.gov (United States)

    Demers, Jason D; Blum, Joel D; Brooks, Scott C; Donovan, Patrick M; Riscassi, Ami L; Miller, Carrie L; Zheng, Wang; Gu, Baohua

    2018-04-25

    Natural abundance stable Hg isotope measurements were used to place new constraints on sources, transport, and transformations of Hg along the flow path of East Fork Poplar Creek (EFPC), a point-source contaminated headwater stream in Oak Ridge, Tennessee. Particulate-bound Hg in the water column of EFPC within the Y-12 National Security Complex, was isotopically similar to average metallic Hg(0) used in industry, having a mean δ202Hg value of -0.42 ± 0.09‰ (1SD) and near-zero Δ199Hg. On average, particulate fraction δ202Hg values increased downstream by 0.53‰, while Δ199Hg decreased by -0.10‰, converging with the Hg isotopic composition of the fine fraction of streambed sediment along the 26 km flow path. The dissolved fraction behaved differently. Although initial Δ199Hg values of the dissolved fraction were also near-zero, these values increased transiently along the flow path. Initial δ202Hg values of the dissolved fraction were more variable than in the particulate fraction, ranging from -0.44 to 0.18‰ among three seasonal sampling campaigns, but converged to an average δ202Hg value of 0.01 ± 0.10‰ (1SD) downstream. Dissolved Hg in the hyporheic and riparian pore water had higher and lower δ202Hg values, respectively, compared to dissolved Hg in stream water. Variations in Hg isotopic composition of the dissolved and suspended fractions along the flow path suggest that: (1) physical processes such as dilution and sedimentation do not fully explain decreases in total mercury concentrations along the flow path; (2) in-stream processes include photochemical reduction, but microbial reduction is likely more dominant; and (3) additional sources of dissolved mercury inputs to EFPC at baseflow during this study predominantly arise from the hyporheic zone.

  10. Low diastolic blood pressure and adverse outcomes in heart failure with preserved ejection fraction.

    Science.gov (United States)

    Tsujimoto, Tetsuro; Kajio, Hiroshi

    2018-07-15

    It remains unknown whether a low diastolic blood pressure (DBP) increases the risks of cardiovascular events and death in patients with heart failure with preserved ejection fraction (HFpEF). We used data from the TOPCAT trial. The primary outcome was a composite of all-cause death, non-fatal myocardial infarction, non-fatal stroke, or hospitalization for heart failure. Hazard ratios (HRs) were analyzed for DBPs of <60, 60-69, 70-79, and ≥90 mm Hg in comparison with a DBP of 80-89 mm Hg using multivariable Cox proportional hazard models. This study included 3417 patients with HFpEF who had a controlled blood pressure. In the mean follow-up period of 3.0 years, 881 patients experienced at least one confirmed primary outcome event. Compared with patients with a DBP of 80-89 mm Hg, the adjusted HRs for primary outcome events were significantly higher in those with DBPs of <60 mm Hg (HR: 2.19 [95% confidence interval,1.72-2.78]) and 60-69 mm Hg (HR: 1.52 [1.23-1.87]). Similarly, the adjusted HRs for all-cause death, major cardiovascular events, and hospitalization for heart failure, but not stroke, were significantly higher in patients with a DBP of <70 mm Hg. A relationship between a low DBP and adverse outcomes was found in HFpEF patients with a systolic blood pressure of ≥120 mm Hg; however, a low systolic blood pressure with a DBP of ≥70 mm Hg was not associated with these event risks. A low DBP increased the risks of adverse outcomes in patients with HFpEF. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Validation of a smartphone auscultatory blood pressure kit Accutension XYZ-110 in adults according to the ANSI/AAMI/ISO 81060-2: 2013 standard.

    Science.gov (United States)

    Chu, Guang; Zhang, Zhi; Xu, Mengdan; Huang, Daini; Dai, Qiuyan

    2017-10-01

    The aim of this study was to validate the accuracy of the Accutension XYZ-110 blood pressure (BP) kit according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 81060-2:2013 standard. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured simultaneously on the same arm in 85 Chinese adults (female : male=48 : 37) with a mean age of 43.2 years using the mercury sphygmomanometer (two observers) and the Accutension XYZ-110 device (one supervisor). The ANSI/AAMI/ISO 81060-2:2013 standard for the validation of BP-measuring devices in adults was followed precisely. A total of 255 comparison pairs were obtained for analysis. The mean device-observer difference in the 255 separate BP data pairs was 2.45±2.24 mmHg for SBP and 0.69±2.09 mmHg for DBP. The data were in accordance with the criterion 1 of the ANSI/AAMI/ISO 81060-2:2013 standard requirements (≤5±8 mmHg). In addition, the mean device-observer difference of the 85 participants was 2.45±1.47 mmHg for SBP and 0.69±1.36 mmHg for DBP. The device accuracy also fulfilled the criterion 2 with the SD of less than or equal to 6.47 for SBP and less than or equal to 6.90 mmHg for DBP. The Accutension XYZ-110 BP kit fulfilled the requirements of the ANSI/AAMI/ISO 81060-2:2013 standard, and hence could be recommended for both clinical and self/home BP measurement in adults.

  12. Jugular venous pooling during lowering of the head affects blood pressure of the anesthetized giraffe.

    Science.gov (United States)

    Brøndum, E; Hasenkam, J M; Secher, N H; Bertelsen, M F; Grøndahl, C; Petersen, K K; Buhl, R; Aalkjaer, C; Baandrup, U; Nygaard, H; Smerup, M; Stegmann, F; Sloth, E; Ostergaard, K H; Nissen, P; Runge, M; Pitsillides, K; Wang, T

    2009-10-01

    How blood flow and pressure to the giraffe's brain are regulated when drinking remains debated. We measured simultaneous blood flow, pressure, and cross-sectional area in the carotid artery and jugular vein of five anesthetized and spontaneously breathing giraffes. The giraffes were suspended in the upright position so that we could lower the head. In the upright position, mean arterial pressure (MAP) was 193 +/- 11 mmHg (mean +/- SE), carotid flow was 0.7 +/- 0.2 l/min, and carotid cross-sectional area was 0.85 +/- 0.04 cm(2). Central venous pressure (CVP) was 4 +/- 2 mmHg, jugular flow was 0.7 +/- 0.2 l/min, and jugular cross-sectional area was 0.14 +/- 0.04 cm(2) (n = 4). Carotid arterial and jugular venous pressures at head level were 118 +/- 9 and -7 +/- 4 mmHg, respectively. When the head was lowered, MAP decreased to 131 +/- 13 mmHg, while carotid cross-sectional area and flow remained unchanged. Cardiac output was reduced by 30%, CVP decreased to -1 +/- 2 mmHg (P blood in the veins. When the head was raised, the jugular veins collapsed and blood was returned to the central circulation, and CVP and cardiac output were restored. The results demonstrate that in the upright-positioned, anesthetized giraffe cerebral blood flow is governed by arterial pressure without support of a siphon mechanism and that when the head is lowered, blood accumulates in the vein, affecting MAP.

  13. Accumulation of Mercury (Hg) and Methyl Mercury (Me Hg) Concentrations In Selected Marine Biota From Manjung Coastal Area

    International Nuclear Information System (INIS)

    Anisa Abdullah; Zaini Hamzah; Ahmad Saat; Ahmad Saat; Abd Khalik Wood; Masitah Alias

    2015-01-01

    Level of mercury (Hg) and methyl mercury (Me Hg) in marine ecosystem has been intensively studied as these toxic substances could be accumulated in the marine biota. This study is focusing on the Hg and Me Hg content in marine biota in Manjung coastal area. This area has high potential being affected by rapid socio-economic development of Manjung area such as heavy industrial activities (coal fired power plant, iron foundries, port development and factories), agricultural runoff, waste and toxic discharge, quarries, housing constructions. It may has a potential risk when released into the atmosphere and dispersed on the surface of water and continue deposited at the bottom of the water and sediment and being absorbed by marine biota. The concentrations of Hg and Me Hg in marine ecosystem can be adversely affect human health when it enters the food chain. In this study, five species of marine biota including Johnius dussumieri (Ikan Gelama), Pseudorhombus malayanus (Ikan Sebelah), Arius maculatus (Ikan Duri), Portunus pelagicus (Ketam Renjong) and Charybdis natator (Ketam Salib) were collected during rainy and dry seasons. Measurements were carried out using inductively coupled plasma mass spectrometry (ICP-MS) technique. The Hg concentrations for dry and rainy season are in the range 65.13-102.12 μg/ kg and 75.75-106.10 μg/ kg respectively, while for MeHg concentrations for dry and rainy seasons are in the range 4.35-6.26 μg/ kg and 5.42-6.46 μg/ kg, respectively. These results are below the limit set by Malaysia Food Act (1983). Generally, marine biota from the Manjung coastal area is safe to consume due to low value of ingestion dose rate and health risk index (HRI) for human health. (author)

  14. Arterial Pressure Gradients during Upright Posture and 30 deg Head Down Tilt

    Science.gov (United States)

    Sanchez, E. R; William, J. M.; Ueno, T.; Ballard, R. E.; Hargens, A. R.; Holton, Emily M. (Technical Monitor)

    1997-01-01

    Gravity alters local blood pressure within the body so that arterial pressures in the head and foot are lower and higher, respectively, than that at heart level. Furthermore, vascular responses to local alterations of arterial pressure are probably important to maintain orthostatic tolerance upon return to the Earth after space flight. However, it has been difficult to evaluate the body's arterial pressure gradient due to the lack of noninvasive technology. This study was therefore designed to investigate whether finger arterial pressure (FAP), measured noninvasively, follows a normal hydrostatic pressure gradient above and below heart level during upright posture and 30 deg head down tilt (HDT). Seven healthy subjects gave informed consent and were 19 to 52 years old with a height range of 158 to 181 cm. A Finapres device measured arterial pressure at different levels of the body by moving the hand from 36 cm below heart level (BH) to 72 cm above heart level (AH) in upright posture and from 36 cm BH to 48 cm AH during HDT in increments of 12 cm. Mean FAP creased by 85 mmHg transitioning from BH to AH in upright posture, and the pressure gradient calculated from hydrostatic pressure difference (rho(gh)) was 84 mmHg. In HDT, mean FAP decreased by 65 mmHg from BH to AH, and the calculated pressure gradient was also 65 mmHg. There was no significant difference between the measured FAP gradient and the calculated pressure gradient, although a significant (p = 0.023) offset was seen for absolute arterial pressure in upright posture. These results indicate that arterial pressure at various levels can be obtained from the blood pressure at heart level by calculating rho(gh) + an offset. The offset equals the difference between heart level and the site of measurement. In summary, we conclude that local blood pressure gradients can be measured by noninvasive studies of FAP.

  15. Central pressures and central hemodynamic values in white coat hypertensives are closer to those of normotensives than to those of controlled hypertensives for similar age, gender, and 24-h and nocturnal blood pressures.

    Science.gov (United States)

    Almeida, Joana; Monteiro, José; Silva, José A; Bertoquini, Susana; Polónia, Jorge

    2016-11-01

    There is disagreement whether white coat hypertensives (WCH) have different hemodynamic and structural characteristics compared to normotensives (NT) and hypertensives (HT). We compared cardiovascular prognostic markers (pulse wave velocity [PWV] and aortic stiffness index [ASI]) and data on central hemodynamics and central pressures (augmentation index [AIx], augmentation pressure [AugP] and pulse pressure amplification [PPA]) from aortic pulse wave analysis between NT (n=175), WCH (n=315) and treated HT (n=691), all with 24-h blood pressure (BP) <130/80 and nocturnal BP <120/70 mmHg after matching for age, gender, body mass index (BMI) and and nocturnal BP. The groups were also compared separately in terms of 24-h systolic BP <120 mmHg and 120-129 mmHg. The percentage of non-dippers was 40.1% in NT, 34.5% in WCH and 38.3 in HT. For similar 24-h and nocturnal systolic BP (NT 109/64±7/5, WCH 110/66±7/6, HT 109/64±7/5 mmHg), aortic stiffness was greater in HT (n=691, PWV 10.8±2.6 m/s and ASI 0.33±0.16, p<0.01) than in WCH (n=316, PWV 9.7±2.4 m/s and ASI 0.28±0.17) and NT (n=175, PWV 9.5±2.0 m/s and ASI 0.29±0.15); AugP and AIx were higher (p<0.01) in HT (13.9±8.2 and 29.6±12.6 mmHg) than in WCH (11.5±8.5 mmHg and 24.9±15.2) and NT (11.0±6.4 mmHg and 26.6±11.5). PPA was lower (p<0.01) in HT (11.3±5.5 mmHg) than in WCH (13.2±7.1 mmHg) and in NT (12.4±4.9 mmHg). The findings were similar when the 24-h systolic BP <120 mmHg and 120-129 mmHg subgroups were analyzed separately. Our data suggest that for similar age, gender distribution, BMI, and 24-h and nocturnal BP, aortic stiffness, central aortic pressures and wave reflection in WCH are closer to those of NT than to those with treated HT. This supports the idea that white coat hypertension may be a more benign condition than treated hypertension for similar 24-h and particularly nocturnal BP levels. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All

  16. Effect of Spinal Manipulation of Upper Cervical Vertebrae on Blood Pressure: Results of a Pilot Sham-Controlled Trial.

    Science.gov (United States)

    Goertz, Christine M; Salsbury, Stacie A; Vining, Robert D; Long, Cynthia R; Pohlman, Katherine A; Weeks, William B; Lamas, Gervasio A

    2016-06-01

    The purpose of this pilot sham-controlled clinical trial was to estimate the treatment effect and safety of toggle recoil spinal manipulation for blood pressure management. Fifty-one participants with prehypertension or stage 1 hypertension (systolic blood pressure ranging from 135 to 159 mm Hg or diastolic blood pressure ranging from 85 to 99 mm Hg) were allocated by an adaptive design to 2 treatments: toggle recoil spinal manipulation or a sham procedure. Participants were seen by a doctor of chiropractic twice weekly for 6 weeks and remained on their antihypertensive medications, as prescribed, throughout the trial. Blood pressure was assessed at baseline and after study visits 1, 6 (week 3), and 12 (week 6), with the primary end point at week 6. Analysis of covariance was used to compare mean blood pressure changes from baseline between groups at each end point, controlling for sex, age, body mass index, and baseline blood pressure. Adjusted mean change from baseline to week 6 was greater in the sham group (systolic, -4.2 mm Hg; diastolic, -1.6 mm Hg) than in the spinal manipulation group (systolic, 0.6 mm Hg; diastolic, 0.7 mm Hg), but the difference was not statistically significant. No serious and few adverse events were noted. Six weeks of toggle recoil spinal manipulation did not lower systolic or diastolic blood pressure when compared with a sham procedure. No serious adverse events from either treatment were reported. Our results do not support a larger clinical trial. Further research to understand the potential mechanisms of action involving upper cervical manipulation on blood pressure is warranted before additional clinical investigations are conducted. Copyright © 2016. Published by Elsevier Inc.

  17. Carbon-13 isotope effects on 199Hg nuclear shielding

    International Nuclear Information System (INIS)

    Sebald, Angelika; Wrackmeyer, Bernd

    1985-01-01

    Secondary 13 C/ 12 C isotope effects on 199 Hg nuclear shielding (Δdeltasup(i)( 199 Hg)) are of interest because of the unusual shift to high frequency which has been observed for a few alkyl mercury compounds. Continuing interest in the NMR parameters of mercury compounds prompted a search for the values Δdeltasup(i)( 199 Hg) in a greater variety of organomercurials. This should help to find out about the range of Δdeltasup(i)( 199 Hg) and to obtain a firmer basis for the discussion of the high-frequency shifts. The data and experimental conditions are given for chemical shifts delta 199 Hg, coupling constants sup(n)J( 199 Hg 13 C) and 13 C/ 12 C isotope shifts Δdeltasup(i)( 199 Hg) of fourteen 199 Hg organomercury compounds. The results are discussed. (author)

  18. Investigation of the Unsteady Total Pressure Profile Corresponding to Counter-Rotating Vortices in an Internal Flow Application

    Science.gov (United States)

    Gordon, Kathryn; Morris, Scott; Jemcov, Aleksandar; Cameron, Joshua

    2013-11-01

    The interaction of components in a compressible, internal flow often results in unsteady interactions between the wakes and moving blades. A prime example in which this flow feature is of interest is the interaction between the downstream rotor blades in a transonic axial compressor with the wake vortices shed from the upstream inlet guide vane (IGV). Previous work shows that a double row of counter-rotating vortices convects downstream into the rotor passage as a result of the rotor blade bow shock impinging on the IGV. The rotor-relative time-mean total pressure distribution has a region of high total pressure corresponding to the pathline of the vortices. The present work focuses on the relationship between the magnitude of the time-mean rotor-relative total pressure profile and the axial spacing between the IGV and the rotor. A survey of different axial gap sizes is performed in a two-dimensional computational study to obtain the sensitivity of the pressure profile amplitude to IGV-rotor axial spacing.

  19. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P blood pressure and HR from daytime...

  20. Landscape controls on total and methyl mercury in the upper Hudson River basin of New York State

    Science.gov (United States)

    Burns, D. A.; Murray, K. R.; Bradley, P. M.; Brigham, M. E.; Aiken, G.; Smith, M.

    2010-12-01

    High levels of mercury (Hg) in aquatic biota have been identified in surface waters of the Adirondack region of New York, and factors such as the prevalence of wetlands, extensive forest cover, and oligotrophic waters promote Hg bioaccumulation in this region. Past research in this region has focused on improved understanding of the Hg cycle in lake ecosystems. In the study described herein, the landscape controls on total Hg and methylmercury (MeHg) concentrations in riverine ecosystems were explored through synoptic surveys of 27 sites in the upper Hudson River basin of the Adirondack region. Stream samples were collected and analyzed for total Hg, MeHg, dissolved organic carbon (DOC), and ultraviolet absorbance at 254 nm (UV254) during spring and summer of 2006-08. Landscape indices including many common land cover, hydrographic, and topographic-based measures were explored as predictors of Hg through multivariate linear regression. Multivariate models that included a wetland or riparian area-based metric, an index for open water area, and in some cases a topographic metric such as the wetness index explained 55 to 65 percent of the variation in MeHg concentrations, and 55 to 80 percent of the variation in total Hg concentrations. An open water index (OWI) was developed that incorporated both the basin area drained by ponded water and the surface area of these ponds. This index was inversely related to concentrations of total Hg and MeHg. This OWI was also inversely related to specific ultra-violet absorbance, consistent with previous studies showing that open water increases the influence of algal-derived carbon on DOC, decreasing aromaticity, which should decrease the ability of the dissolved carbon pool to bind Hg. The OWI was not significant in models for total Hg that also included UV254 as a predictive variable, but the index did remain significant in similar models for MeHg suggesting that biogeochemical factors in addition to decreasing carbon

  1. Early Hg mobility in cultivated tropical soils one year after slash-and-burn of the primary forest, in the Brazilian Amazon.

    Science.gov (United States)

    Béliveau, Annie; Lucotte, Marc; Davidson, Robert; Lopes, Luis Otávio do Canto; Paquet, Serge

    2009-07-15

    In the Brazilian Amazon, forest conversion to agricultural lands (slash-and-burn cultivation) contributes to soil mercury (Hg) release and to aquatic ecosystem contamination. Recent studies have shown that soil Hg loss occurs rapidly after deforestation, suggesting that Hg mobility could be related to the massive cation input resulting from biomass burning. The objective of this research was to determine the effects of the first year of slash-and-burn agriculture on soil Hg levels at the regional scale of the Tapajós River, in the state of Pará, Brazilian Amazon. A total of 429 soil samples were collected in 26 farms of five riparian communities of the Tapajós basin. In September 2004, soil samples were collected from primary forest sites planned for slash-and-burn cultivation. In August 2005, one year after the initial burning, a second campaign was held and the exact same sites were re-sampled. Our results showed that total Hg levels in soils did not change significantly during the first year following slash-and-burn, suggesting no immediate release of soil Hg at that point in time. However, an early Hg mobility was detected near the surface (0-5 cm), reflected by a significant shift in Hg distribution in soil fractions. Indeed, a transfer of Hg from fine to coarser soil particles was observed, indicating that chemical bonds between Hg and fine particles could have been altered. A correspondence analysis (CA) showed that this process could be linked to a chemical competition caused by cation enrichment. The regional dimension of the study highlighted the prevailing importance of soil types in Hg dynamics, as shown by differentiated soil responses following deforestation according to soil texture. Confirming an early Hg mobility and indicating an eventual Hg release out of the soil, our results reinforce the call for the development of more sustainable agricultural practices in the Amazon.

  2. Impact of mean arterial pressure on sublingual microcirculation during cardiopulmonary bypass - secondary outcome from a randomised clinical trial

    DEFF Research Database (Denmark)

    Holmgaard, Frederik; Vedel, Anne G; Ravn, Hanne Berg

    2018-01-01

    . METHODS: Thirty-six cardiac surgery patients undergoing coronary artery bypass grafting were included and randomised to either low (40-50 mmHg) or high (70-80 mmHg) mean arterial pressure during cardiopulmonary bypass. Sidestream Dark Field video images were recorded from the sublingual mucosa. Recordings...... were analysed in a blinded fashion to quantify microcirculatory variables. RESULTS: Mean arterial pressure during cardiopulmonary bypass in the low target group was 45.0 mmHg (SD 5.3) vs. 67.2 mmHg (SD 8.9) in the high target group. We found no significant difference between the two groups......OBJECTIVE: In this substudy of a randomised, clinical trial, we explored the sublingual microcirculation during cardiac surgery at two different levels of blood pressure. We hypothesised that a higher mean arterial pressure during cardiopulmonary bypass would cause higher Microvascular Flow Index...

  3. Blood pressure and falls in community-dwelling people aged 60 years and older in the VHM&PP cohort.

    Science.gov (United States)

    Klein, Diana; Nagel, Gabriele; Kleiner, Andrea; Ulmer, Hanno; Rehberger, Barbara; Concin, Hans; Rapp, Kilian

    2013-05-21

    Falls are one of the major health problems in old people. Different risk factors were identified but only few epidemiological studies analysed the influence of conventionally measured blood pressure on falls. The objective of our study was to investigate the relationship between systolic and diastolic blood pressure and falls. In 3,544 community-dwelling Austrian women and men aged 60 years and older, data on falls within the previous three months were collected by questionnaire. Blood pressure was measured by general practitioners within the Vorarlberg Health Monitoring and Prevention Programme (VHM&PP) 90 to 1095 days before the fall assessment. A multiple logistic regression analysis was conducted. The models were stratified by gender and adjusted by age, number of medical conditions and subjective feeling of illness. In total, 257 falls in 3,544 persons were reported. In women, high systolic and diastolic blood pressure was associated with a decreased risk of falls. An increase of systolic blood pressure by 10 mmHg and of diastolic blood pressure by 5 mmHg reduced the risk of falling by 9% (OR 0.91, 95% Cl 0.84-0.98) and 8% (OR 0.92, 95% Cl 0.85-0.99), respectively. In men, an increased risk of falls was observed in participants with low systolic or low diastolic blood pressure. Blood pressure was associated with the risk of falls. Hypertensive values decreased the risk in women and low blood pressure increased the risk in men.

  4. Influence of defect structure on magnetic and electronic properties of Hg1-x Crx Se and Hg1-x Cox Se

    International Nuclear Information System (INIS)

    Prozorovskij, V.D.; Reshidova, I.Yu.; Puzynya, A.I.; Paranchich, Yu.S.

    1996-01-01

    The results of experimental investigations of the Shubnikov-de Haas oscillations at superhigh frequencies, electron spin resonance, magnetic susceptibility, relaxation dielectric losses, and galvanomagnetic measurements in the Hg 1-x Cr x Se and Hg 1-x Co x Se single crystal samples are presented. Analysis of the results Hg 1-x Cr x Se and Hg 1-x Co x Se depend on the defect structure of the substance and the type of defects making this structure. The manifestation of critical phenomena in Hg 1-x Cr x Se also depends on the defect structure

  5. Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Chahine, Mirna N; Ibanez, Isabel; Assemani, Nathalie; Asmar, Roland

    2014-01-01

    Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. The four devices measure brachial blood pressure (BP) using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg). The protocol procedures were followed precisely in each of the four studies. All four tested devices passed the validation process. The mean differences between the device and mercury readings were: -1.8±5.1 mmHg and -0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and -1.2±4.3 mmHg for the Omron HEM-7420 device; -0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device. Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly.

  6. Effects of the November 2012 Flood Event on the Mobilization of Hg from the Mount Amiata Mining District to the Sediments of the Paglia River Basin

    Directory of Open Access Journals (Sweden)

    Giulia Pattelli

    2014-04-01

    Full Text Available The Mount Amiata mining district (southern Tuscany, Italy was, for decades, one of the world’s largest mercury (Hg producing regions, where mining activity lasted until the 1980s. The Paglia River drains the eastern part of the district and is also the main western tributary of the Tiber River. Recent studies show that, still today, high total Hg contents severely affect the downstream ecosystems of these rivers. In November 2012, a major flood event occurred in the Paglia River basin, which drastically changed the river morphology and, possibly, the Hg concentrations. In the present work, stream sediment was sampled before and after the flood to evaluate possible changes in sediment total Hg concentrations as a consequence of this event. The comparison between pre- and post-flood Hg concentrations shows that Hg content increased up to an order of magnitude after the flood, suggesting that this event triggered Hg mobilization in the basin rather than its dilution.

  7. Intraocular pressure spike after YAG iridotomy in patients with pigment dispersion.

    Science.gov (United States)

    Birt, Catherine M

    2004-04-01

    The role of laser peripheral iridotomy to break a suspected reverse pupil block in the long-term control of pigment dispersion is promising, but the usefulness of this procedure has not been completely established. The author examined whether patients with pigment dispersion are at higher risk for an intraocular pressure (IOP) spike after laser peripheral iridotomy due to possible compromise of trabecular meshwork function, compared with patients undergoing prophylactic peripheral iridotomy for an occludable angle. Data were collected prospectively on the first eye of 87 patients with occludable angles and 13 patients with pigment dispersion treated with peripheral laser iridotomy between November 1995 and October 1996 at the glaucoma service of a university-affiliated hospital in Toronto. All patients received one drop of 0.5% apraclonidine before the procedure. IOP was measured before and 1 and 24 hours after the procedure. There was no difference between the two groups in the distribution of right vs. left eyes, sex, race, the mean total energy required to produce a patent iridotomy, the mean number of medications used or the mean IOP before the procedure. The patients with pigment dispersion were significantly younger than those with occludable angles (mean age [and standard deviation (SD)] 40.5 [9.45] years vs. 66.4 [10.78] years) (p pigment dispersion group had an IOP spike greater than 2 mm Hg after the procedure (p = 0.001). Among these patients, the mean IOP (36.4 [SD 10.83] mm Hg vs. 30.3 [SD 7.04] mm Hg, p = 0.05) and the mean rise in IOP (14.0 [SD 10.63] mm Hg vs. 8.7 [SD 4.73] mm Hg, p = 0.04) were significantly higher in those with pigment dispersion than in those with occludable angles. Among the patients who used antiglaucoma medications before the procedure or had a prelaser IOP level greater than 22 mm Hg, those with pigment dispersion were more likely than those with occludable angles to have an IOP spike at 1 hour (p pigment dispersion

  8. Effects of the ankle-brachial blood pressure index and skin perfusion pressure on mortality in hemodialysis patients.

    Science.gov (United States)

    Otani, Yumi; Otsubo, Shigeru; Kimata, Naoki; Takano, Mari; Abe, Takayuki; Okajima, Tomoki; Miwa, Naoko; Tsuchiya, Ken; Nitta, Kosaku; Akiba, Takashi

    2013-01-01

    Clinically, the ankle-brachial blood pressure index (ABI) and skin perfusion pressure (SPP) are used to screen for subclinical peripheral artery disease. However, the association between the SPP and mortality in hemodialysis patients has not been previously reported. We investigated these factors and compared the ABI and SPP in patients receiving hemodialysis. A total of 102 patients receiving maintenance hemodialysis were enrolled in this study. The ABI was determined using an ABI-form (Colin, Japan). The SPP was measured using a SensiLase(TM) PAD3000 (Kaneka, Osaka, Japan). The mean follow-up period was 3.2 ± 1.4 years. A multivariate Cox analysis identified a low ABI (p=0.019) and a low SPP (p=0.047) as being independent predictors of mortality. A receiver operating characteristic (ROC) analysis of the ABI revealed a cutoff point of 1.1 and an area under the curve (AUC) of 0.79, with a sensitivity of 90% and a specificity of 62%. A ROC analysis of the SPP revealed a cutoff point of 54.0 mmHg and an AUC of 0.71, with a sensitivity of 55% and a specificity of 84%. Both low ABI and SPP values were found to be independent risk factors for mortality among hemodialysis patients. The cutoff point for ABI as a predictor of mortality was 1.1, while that for SPP was 54.0 mmHg.

  9. Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.

    Science.gov (United States)

    Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo

    2017-01-01

    Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Retrocalcaneal bursitis but not Achilles tendinopathy is characterized by increased pressure in the retrocalcaneal bursa.

    Science.gov (United States)

    Lohrer, Heinz; Nauck, Tanja

    2014-03-01

    We questioned whether different forms of Achilles tendon overuse injuries can be differentiated by retrocalcaneal bursa pressure measurement. Retrocalcaneal bursa pressure was determined by using invasive pressure measurement in patients suffering from retrocalcaneal bursitis (n=13) or Achilles tendinopathy (n=15), respectively. Standardized measurements were taken with the subject lying prone. Initially, the foot and ankle was in a spontaneous, unsupported position. Then passive dorsiflexion was induced by an increasing pressure which was applied in five defined steps against the plantar forefoot. Mean pressures found in unloaded position were 30.5 (SD 28.9) mmHg in retrocalcaneal bursitis and -9.9 (SD 17.2) mmHg in Achilles tendinopathy (pbursitis and 32.5 (SD 48.9) mmHg for Achilles tendinopathy (p=0,051). Higher retrocalcaneal bursa pressure values were found in patients suffering from chronic retrocalcaneal bursitis. This result supports the hypothesis that retrocalcaneal bursa hypertension leads to an impingement lesion of the corresponding anterior Achilles tendon. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Interarm blood pressure difference in a post-stroke population.

    Science.gov (United States)

    Gaynor, Eva; Brewer, Linda; Mellon, Lisa; Hall, Patricia; Horgan, Frances; Shelley, Emer; Dolan, Eamonn; Hickey, Anne; Bennett, Kathleen; Williams, David J

    2017-09-01

    An increased interarm systolic blood pressure (SBP) difference of ≥10 mm Hg is associated with increased cardiovascular risk and a difference of ≥15 mm Hg with increased cerebrovascular risk. The stroke population presents a high-risk group for future cardiovascular and cerebrovascular events and therefore estimation of interarm SBP difference as a predictive tool may assist with further secondary stroke prevention. The aim of the study was to determine the prevalence of interarm SBP and diastolic blood pressure difference in a post-stroke population. A comprehensive assessment of secondary risk factors along with blood pressure measurements were taken 6-months' post-ischemic stroke from the Action on Secondary Prevention Interventions and Rehabilitation in Stroke cohort. Descriptive and logistic regression analyses were performed. Odds ratios and 95% confidence intervals are presented. Two hundred thirty-eight (M: F,139:99; mean age, 68.4 years) of 256 patients followed up at 6 months post-stroke had suitable blood pressure readings from both arms. Ninety-six patients (40.3%) had an interarm SBP difference of ≥10 mm Hg and 49 (20.6%) had a difference of ≥15 mm Hg. A history of hypertension, diabetes, smoking, and obesity was not significantly associated with an increased risk of interarm SBP difference. After multivariate logistic analysis, a history of alcohol excess was associated with an increased IASBP ≥15 mm Hg (odds ratio 2.32, 95% confidence interval 1.03-5.22). We have demonstrated that interarm SBP difference is commonly seen in a post stroke population. Copyright © 2017 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  12. 40 CFR 60.4114 - Objections concerning Hg designated representative.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Objections concerning Hg designated... Times for Coal-Fired Electric Steam Generating Units Hg Designated Representative for Hg Budget Sources § 60.4114 Objections concerning Hg designated representative. (a) Once a complete certificate of...

  13. Intraocular pressure, corneal thickness, and corneal hysteresis in Steinert's myotonic dystrophy

    Directory of Open Access Journals (Sweden)

    Carlos Alexandre de A. Garcia Filho

    2011-06-01

    Full Text Available PURPOSE: Low intraocular pressure (IOP measured by Goldmann applanation tonometry (GAT is one of the ocular manifestations of Steinert's myotonic dystrophy. The goal of this study was to evaluate the corneal-compensated IOP as well as corneal properties (central corneal thickness and corneal hysteresis in patients with myotonic dystrophy. METHODS: A total of 12 eyes of 6 patients with Steinert's myotonic dystrophy (dystrophy group and 12 eyes of 6 age-, race-, and gender-matched healthy volunteers (control group were included in the study. GAT, Dynamic Contour Tonometry (DCT-Pascal and Ocular Response Analyzer (ORA were used to assess the IOP. Central corneal thickness was obtained by ultrasound pachymetry, and corneal hysteresis was analyzed using the ORA device. In light of the multiplicity of tests performed, the significance level was set at 0.01 rather than 0.05. RESULTS: The mean (standard deviation [SD] GAT, DCT, and corneal-compensated ORA IOP in the dystrophy group were 5.4 (1.4 mmHg, 9.7 (1.5 mmHg, and 10.1 (2.6 mmHg, respectively. The mean (SD GAT, DCT, and corneal-compensated ORA IOP in the control group was 12.6 (2.9 mmHg, 15.5 (2.7 mmHg, and 15.8 (3.4 mmHg, respectively. There were significant differences in IOP values between dystrophy and control groups obtained by GAT (mean, -7.2 mmHg; 99% confidence interval [CI], -10.5 to -3.9 mmHg; P<0.001, DCT (mean, -5.9 mmHg; 99% CI, -8.9 to -2.8 mmHg; P<0.001, and corneal-compensated ORA measurements (mean, -5.7 mmHg; 99% CI, -10.4 to -1.0 mmHg; P=0.003. The mean (SD central corneal thickness was similar in the dystrophy (542 [31] µm and control (537 [11] µm groups (P=0.65. The mean (SD corneal hysteresis in the dystrophy and control groups were 11.2 (1.5 mmHg and 9.7 (1.2 mmHg, respectively (P=0.04. CONCLUSIONS: Patients with Steinert's myotonic dystrophy showed lower Goldmann and corneal-compensated IOP in comparison with healthy individuals. Since central corneal thickness and

  14. Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

    Science.gov (United States)

    Tanton, George; Kesmodel, Roy; Burden, Judy; Su, Ching-Hua; Cobb, Sharon D.; Lehoczky, S. L.

    2000-01-01

    , obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

  15. Uptake and clearance of mercury Hg (NO3)2-203Hg by the guppy (Lebistes reticulatus)

    International Nuclear Information System (INIS)

    Ferreira, J.R.; Rodrigues, N.S.; Nascimento Filho, V.F. do

    1982-01-01

    Fishes weighing between 20.6 and 536.9 mg were exposed to 25, 50 and 100 μg Hg.l -1 as Hg (NO 3 ) 2 labelled with 203 Hg, for 17 days in plastic aquaria containing 4 litre of soft aerated dechlorinated water. Whole body mercury contents were determined periodically by gamma counting, using a single channel spectrometer and a 3 in X 3 in NaI(Tl) well crystal. The highest bioconcentration of mercury was after 100 h of exposure for all the treatments. A further study on the clearance of mercury nitrate was carried out by transfering fishes to mercury-free water, after a period of 100 h of exposure in solutions of 35 and μg Hg.l -1 . The fishes were not sacrificed after the dose measurment, being returned to the aquaria for further sampling. The rate of clearance was similar for both concentrations. After 120 h exposure to uncontamined water, the fishes excreted the mercury previously absorbed. The correlation coefficient of the experimentals equations were 0.91 and 0.94, respectively, for the treatments 35 and 70 μg Hg.l -1 . Both experiments, uptake and clearance were made at same values of the water physico-chemical parameters (hardness = 36 mg CaCO 3 ; pH=7.2; O.D.=7.0 mg/l; temperature=23 +- 1 0 C). (Author) [pt

  16. The new barium zinc mercurides Ba3ZnHg10 and BaZn0.6Hg3.4 – Synthesis, crystal and electronic structure

    International Nuclear Information System (INIS)

    Schwarz, Michael; Wendorff, Marco; Röhr, Caroline

    2012-01-01

    The title compounds Ba 3 ZnHg 10 and BaZn 0.6 Hg 3.4 were synthesized from stoichiometric ratios of the elements in Ta crucibles. Their crystal structures, which both represent new structure types, have been determined using single crystal X-ray data. The structure of Ba 3 ZnHg 10 (orthorhombic, oP28, space group Pmmn, a=701.2(3), b=1706.9(8), c=627.3(3)pm, Z=2, R1=0.0657) contains folded 4 4 Hg nets, where the meshes form the bases of flat rectangular pyramids resembling the structure of BaAl 4 . The flat pyramids are connected via Hg–Zn/Hg bonds, leaving large channels at the folds, in which Ba(1) and Hg(2) atoms alternate. Whereas the remaining Hg/Zn atoms form a covalent 3D network of three- to five-bonded atoms with short M–M distances (273–301 pm; CN 9–11), the Hg(2) atoms in the channels adopt a comparatively large coordination number of 12 and increased distances (317–348 pm) to their Zn/Hg neighbours. In the structure of BaZn 0.6 Hg 3.4 (cubic, cI320, space group I4 ¯ 3d, a=2025.50(7) pm, Z=64, R1=0.0440), with a chemical composition not much different from that of Ba 3 ZnHg 10 , the Zn/Hg atoms of the mixed positions M(1/2) are arranged in an slightly distorted primitive cubic lattice with a 4×4×4 subcell relation to the unit cell. The 24 of the originating 64 cubes contain planar cis tetramers Hg(5,6) 4 with Hg in a nearly trigonal planar or tetrahedral coordination. In another 24 of the small cubes, two opposing faces are decorated by Hg(3,4) 2 dumbbells, two by Ba(2) atoms respectively. The third type of small cubes are centered by Ba(1) atoms only. The complex 3D polyanionic Hg/Zn network thus formed is compared with the Hg partial structure in Rb 3 Hg 20 applying a group-subgroup relation. Despite their different overall structures, the connectivity of the negatively charged Hg atoms, the rather metallic Zn bonding characteristic (as obtained from FP-LAPW band structure calculations) and the coordination number of 16 for all Ba cations

  17. Accumulation of total mercury and methylmercury in rice plants collected from different mining areas in China

    International Nuclear Information System (INIS)

    Meng, Mei; Li, Bing; Shao, Jun-juan; Wang, Thanh; He, Bin; Shi, Jian-bo; Ye, Zhi-hong; Jiang, Gui-bin

    2014-01-01

    A total of 155 rice plants were collected from ten mining areas in three provinces of China (Hunan, Guizhou and Guangdong), where most of mercury (Hg) mining takes place in China. During the harvest season, whole rice plants were sampled and divided into root, stalk and leaf, husk and seed (brown rice), together with soil from root zone. Although the degree of Hg contamination varied significantly among different mining areas, rice seed showed the highest ability for methylmercury (MeHg) accumulation. Both concentrations of total mercury (THg) and MeHg in rice plants were significantly correlated with Hg levels in soil, indicating soil is still an important source for both inorganic mercury (IHg) and MeHg in rice plants. The obvious discrepancy between the distribution patterns of THg and MeHg reflected different pathways of IHg and MeHg accumulation. Water soluble Hg may play more important role in MeHg accumulation in rice plants. -- Highlights: • Distribution patterns indicated different pathways of IHg and MeHg accumulation. • Soil is an important source for both THg and MeHg to rice plants. • Water soluble Hg may play more important role in MeHg accumulation in rice plants. -- The distribution patterns indicate different pathways of IHg and MeHg accumulation in rice plants

  18. Ab initio study of structural, electronic and optical properties of MnHg(SCN){sub 4} and FeHg(SCN){sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    He, K.H. [College of Maths and Physics, China University of Geosciences, Wuhan 430074 (China)]. E-mail: he23981006@126.com; Zheng, G. [College of Maths and Physics, China University of Geosciences, Wuhan 430074 (China)]. E-mail: gzheng25@yahoo.com; Chen, G. [College of Maths and Physics, China University of Geosciences, Wuhan 430074 (China); Lue, T. [College of Maths and Physics, China University of Geosciences, Wuhan 430074 (China); Wan, M. [College of Maths and Physics, China University of Geosciences, Wuhan 430074 (China); Ji, G.F. [Laboratory for Shock Wave and Detonation Physics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2007-03-01

    The structural, electronic and optical properties of MnHg(SCN){sub 4} and FeHg(SCN){sub 4} were studied by means of quantum-mechanical calculations based on the density-functional theory and pseudopotential method. The lattice constants can be compared with the experimental values when the effects of temperature are considered. The peaks of partial density of states of S, C, N and Hg of FeHg(SCN){sub 4} have a tendency of shifting to the higher energy levels relative to those of MnHg(SCN){sub 4}. The distributions of the 3d electronic states in the transition metal atoms show quite large difference and decide different optical properties. We found that absorptional peaks of FeHg(SCN){sub 4} lag behind those of MnHg(SCN){sub 4} and the peak in the infrared range has a higher absorptional intensity, which are in accord with the experimental results. By analyzing the distributions and transitions of the 3d electronic states, we explained the different absorption phenomena.

  19. Determination of total carbonates in soil archaeometry using a new pressure method with temperature compensation

    Science.gov (United States)

    Barouchas, Pantelis; Koulos, Vasilios; Melfos, Vasilios

    2017-04-01

    For the determination of total carbonates in soil archaeometry a new technique was applied using a multi-sensor philosophy, which combines simultaneous measurement of pressure and temperature. This technology is innovative and complies with EN ISO 10693:2013, ASTM D4373-02(2007) and Soil Science Society of America standard test methods for calcium carbonate content in soils and sediments. The total carbonates analysis is based on a pressure method that utilizes the FOGII Digital Soil CalcimeterTM, which is a portable apparatus. The total carbonate content determined by treating a 1.000 g (+/- 0.001 g) dried sample specimens with 6N hydrochloric acid (HCL) reagent grade, in an enclosed reaction vessel. Carbon dioxide gas evolved during the reaction between the acid and carbonate fraction of the specimen, was measured by the resulting pressure generated, taking in account the temperature conditions during the reaction. Prior to analysis the procedure was validated with Sand/Soil mixtures from BIPEA proficiency testing program with soils of different origins. For applying this new method in archaeometry a total number of ten samples were used from various rocks which are related with cultural constructions and implements in Greece. They represent a large range of periods since the Neolithic times, and were selected because there was an uncertainty about their accurate mineralogical composition especially regarding the presence of carbonate minerals. The results were compared to the results from ELTRA CS580 inorganic carbon analyzer using an infrared cell. The determination of total carbonates for 10 samples from different ancient sites indicated a very good correlation (R2 >0.97) between the pressure method with temperature compensation and the infrared method. The proposed method is quickly and accurate in archaeometry and can replace easily other techniques for total carbonates testing. The FOGII Digital Soil CalcimeterTM is portable and easily can be carried for

  20. Screening of native plant species for phytoremediation potential at a Hg-contaminated mining site.

    Science.gov (United States)

    Marrugo-Negrete, José; Marrugo-Madrid, Siday; Pinedo-Hernández, José; Durango-Hernández, José; Díez, Sergi

    2016-01-15

    Artisanal and small-scale gold mining (ASGM) is the largest sector of demand for mercury (Hg), and therefore, one of the major sources of Hg pollution in the environment. This study was conducted in the Alacrán gold-mining site, one of the most important ASGM sites in Colombia, to identify native plant species growing in Hg-contaminated soils used for agricultural purposes, and to assess their potential as phytoremediation systems. Twenty-four native plant species were identified and analysed for total Hg (THg) in different tissues (roots, stems, and leaves) and in underlying soils. Accumulation factors (AF) in the shoots, translocation (TF) from roots to shoots, and bioconcentration (BCF) from soil-to-roots were determined. Different tissues from all plant species were classified in the order of decreasing accumulation of Hg as follows: roots > leaves > stems. THg concentrations in soil ranged from 230 to 6320 ng g(-1). TF values varied from 0.33 to 1.73, with high values in the lower Hg-contaminated soils. No correlation was found between soils with low concentrations of Hg and plant leaves, indicating that TF is not a very accurate indicator, since most of the Hg input to leaves at ASGM sites comes from the atmosphere. On the other hand, the BCF ranged from 0.28 to 0.99, with Jatropha curcas showing the highest value. Despite their low biomass production, several herbs and sub-shrubs are suitable for phytoremediation application in the field, due to their fast growth and high AF values in large and easily harvestable plant parts. Among these species, herbs such as Piper marginathum and Stecherus bifidus, and the sub-shrubs J. curcas and Capsicum annuum are promising native plants with the potential to be used in the phytoremediation of soils in tropical areas that are impacted by mining.