WorldWideScience

Sample records for hepatobiliary imaging agents

  1. Value of an hepatobiliary imaging agent for diagnosing hepatoma. Example of diethyl-IDA

    Bourguet, P.; Estable, P.; Herry, J.Y.

    1985-01-01

    A comparative study was performed using two hepatic tracers, a Tc 99m labelled colloid and an hepatobiliary agent Tc 99m labelled diethyl-IDA. In some patients with isolated primary hepatocarcinoma the uptake of the hepatobiliary agent was observed but the colloid was not taken up. In the contrary, the hepatobiliary agent has proved to be of limited value for the diagnosis of hepatomas coexisting with cirrhosis and for the detection of secondary hepatocarcinoma [fr

  2. Value of an hepatobiliary imaging agent for diagnosing hepatoma. Example of diethyl-IDA

    Bourguet, P; Estable, P; Herry, J Y

    1985-01-01

    A comparative study was performed using two hepatic tracers, a Tc 99m labelled colloid and an hepatobiliary agent Tc 99m labelled diethyl-IDA. In some patients with isolated primary hepatocarcinoma the uptake of the hepatobiliary agent was observed but the colloid was not taken up. In the contrary, the hepatobiliary agent has proved to be of limited value for the diagnosis of hepatomas coexisting with cirrhosis and for the detection of secondary hepatocarcinoma.

  3. Hepatobiliary imaging

    Klingensmith, W.C.

    1988-01-01

    If the gallbladder is not being evaluated, no patient preparation is necessary. However, if the gallbladder is being evaluated, the patient must have fasted for approximately 2-14 hr prior to injection of the radiopharmaceutical. If the patient has fasted for less than 2 hr. the gallbladder may still be contracting and, thus, prevent the inflow of radioactive bile. On the other hand, if the patient has fasted for more than 14 hr. the gallbladder may have concentrated its contents to the point where the osmotic gradient prevents further reabsorption of water. The author discusses how, in this situation, an analog of cholecystokinin-pancreazymin such as sincalide can be given intravenously approximately 20 min before injection of the radiopharmaceutical. This agent will cause the gallbladder to empty so that reabsorption of water and filling of the gallbladder can begin again

  4. Iron-EHPG as an hepatobiliary MR contrast agent: initial imaging and biodistribution studies

    Lauffer, R.B.; Greif, W.L.; Stark, D.D.; Vincent, A.C.; Saini, S.; Wedeen, V.J.; Brady, T.J.

    1988-01-01

    A paramagnetic relaxation agent targeted to functioning hepatocytes of the liver and excreted into the bile would be useful in the enhancement of normal liver and biliary anatomy in MR imaging. We sought to demonstrate the feasibility of this approach using the prototype hepatobiliary MR contrast agent, iron(III) ethylenebis-(2-hydroxyphenylglycine) (Fe(EHPG) - ). The biodistribution, relaxation enhancement, and imaging characteristics of Fe(EHPG) - were compared to those of the non-specific iron chelate iron(III) diethylenetriaminepentaacetic acid (Fe(DTPA) 2- ), which has a comparable effect on water proton relaxation times. (author)

  5. Imaging in hepatobiliary disease

    Dooley, J.

    1987-01-01

    This book covers the diagnostic and interventional use of imaging techniques in hepatobiliary disease. The first of the book's two sections describes the role of imaging in the diagnostic work up of common clinical syndromes. The second part is concerned with therapy and reviews interventional techniques for hepatobiliary disease

  6. Radiopharmaceuticals for hepatobiliary imaging

    Chervu, L.R.; Nunn, A.D.; Loberg, M.D.

    1982-01-01

    Tests for liver function have by and large centered around clinical laboratory diagnostic procedures for a number of years. Besides these, radiographic imaging procedures, including oral cholecystography and intravenous cholangiography, serve a very useful purpose, but several of them are invasive and involve a certain degree of risk from the administered contrast media as well as discomfort to the patient. The cholescintigraphic procedures, though noninvasive, have not played a significant role in the evaluation of hepatobiliary disorders prior to the introduction of the currently available /sup 99m/Tc-labeled IDAs. These new hepatobiliary agents offer many advantages over the previously utilized radiopharmaceuticals ( 131 I-rose bengal in particular) in terms of the high degree of specificity for localization in the gallbladder with rapid extraction rates by the polygonal cells of the liver and very low excretion via the GU tract. A detailed understanding of the structure distribution relationship of the various groups in the complex enable the design of agents with an improvement in hepatobiliary specificity and other desirable characteristics. In many clinical situations, even in patients with high bilirubin levels, the /sup 99m/Tc-labeled IDAs offer far superior clinical information over the alternative diagnostic imaging modalities. Further, the absorbed radiation dose imparted to the critical organs is far lower than with the older agents. Thus, the introduction of the cholescintigraphic procedures with the /sup 99m/Tc-labeled IDAs have ushered in a new phase in the diagnostic workup of patients with impaired hepatocellular function and other biliary disorders

  7. 99mTc-O2S4: a new generation hepatobiliary imaging agent

    Babbar, A.K.; Mathur, R.; Katiyar, N.; Dutta, M.; Flora; Mishra, A.K.; Yadav, A.

    2010-01-01

    Full text: Hepatobiliary imaging radionuclide - 99m Tc-Mebrofenin is indicated as a hepatobiliary imaging agent for the evaluation of hepatobiliary tract patency to differentiate jaundice resulting from hepatocellular causes from jaundice resulting from partial or complete biliary obstruction; to differentiate extrahepatic biliary atresia from neonatal hepatitis; to detect cystic duct obstruction associated with acute cholecystitis; and to detect bile leaks. Also, 99m Tc-Mebrofenin may be useful to detect intrahepatic cholestasis and to distinguish it from other hepatobiliary diseases, which involve hepatocyte damage. However, the Mebrofenin kit has to be obtained at an exorbitant cost and there was need to develop an indigenous kit that was readily available and could give similar results. For the first time in India, a derivative of DMSA developed by DRDE, Gwalior and modified at INMAS, Delhi to adopt early transition metals, was successfully labelled with 99m Tc (LE>99%). The reaction conditions were optimized after studying the effects of amount of SnCl 2 , pH of the reaction and effect of incubation time. The labelled product 99m Tc-O 2 S 4 , was characterized by ITLC-SG using acetone and saline. The complex was found to be fairly stable at room temperature and showed>95% plasma protein binding. The biodistribution studies showed that after intravenous administration, there was immediate accumulation of radioactivity in liver, the activity kept on increasing in gall bladder with time and thereafter the radioactivity moved to common bile duct (CBD) and small intestines. No significant radioactivity was found in kidneys and blood. Clear visualization of the gallbladder and intestines, within 15 to 45 minutes of administration of 99m Tc-O 2 S 4 in normal rabbit, demonstrates hepatobiliary tract patency of the newly developed radiotracer. The dynamic and static images showed that the newly developed radiopharmaceutical 99m Tc-O 2 S 4 has full potential in studying

  8. Evaluation of six new /sup 99m/Tc-IDA agents for hepatobiliary imaging

    Chervu, L.R.; Joseph, J.A.; Chun, S.B.; Rolleston, R.E.; Synnes, E.I.; Thompson, L.M.; Aldis, A.E.; Rosenthall, L.

    1988-10-01

    IDA derivatives of three substituted benzothiazol, and two substituted chlorophenyl and one substituted pyrazoline compounds have been labeled with /sup 99m/Tc and screened with four rat models with hepatocellular dysfunction manifesting varying degrees of change of liver architecture and hepatocellular damage associated with an active parenchymal destruction, fatty metamorphosis and cirrhosis. Organ distribution studies at 1 h postinjection have been compared in normal and diseased animal models for each agent labeled with /sup 99m/Tc and with /sup 99m/Tc-Disofenin (Disida) and Lidofenin (Hida) and /sup 131/I-Rose Bengal. From the data obtained with the six new IDA derivatives, the distribution kinetics of /sup 99m/Tc-Arclophenin, (N-N'-2-benzoyl-4-chlorophenyl)carbamoylmethyl) imino diacetic acid (Phenida), are closely comparable to /sup 99m/Tc-Disofenin in all animal models. Crossover patient studies (n = 14) for clinical evaluation of /sup 99m/Tc-Arclophenin vs /sup 99m/Tc-Disofenin indicate the close similarity of the 2 agents with regard to blood pool retention, gross liver/heart ratios and liver washout, suggesting Arclophenin as a suitable agent for hepatobiliary function studies. The impaired hepatocellular animal models presented should serve for fast screening of hepatobiliary agents and enable comparison of a series of closely related compounds.

  9. Evaluation of 99mTc-Mercaptoacetyltriglycine-Biocytin as a new hepatobiliary imaging agent in mice coinjected with bilirubin

    Kim, Meyoung-kon; Seidel, Juergen; Le Nhat; Kim, In-Sook; Yoo, Tae-Moo; Barker, Craig; Kobayashi, Hisataka; Green, Michael V.; Carrasquillo, Jorge A.; Paik, Chang H.

    1999-01-01

    We evaluated 99m Tc-labeled mercaptoacetyltriglycine ( 99m Tc-MAG3)-biocytin as a hepatobiliary imaging agent in the absence and presence of bilirubin in mice. We then compared its pharmacokinetic parameters; peak liver/heart activity ratio (r max ) and half clearance time (HCT) with those of 99m Tc-labeled diisopropyl-iminodiacetic acid ( 99m Tc-disofenin). Balb/c mice were injected intravenously with hepatobiliary agent ( 99m Tc-MAG3-biocytin or 99m Tc-disofenin) alone or in combination with bilirubin at two doses (7 and 14 mg/kg) dissolved in 5% human serum albumin. Images were acquired every 15 s for 30 min with a gamma-camera equipped with a pinhole collimator. Dynamic images showed rapid hepatic uptake of 99m Tc-MAG3-biocytin, with rapid clearance from the blood and rapid excretion via the biliary system. Its hepatic uptake was not affected by bilirubin coinjection, whereas 99m Tc-disofenin coinjected with bilirubin showed a higher blood background than 99m Tc-disofenin alone. These qualitative findings were reflected in pharmacokinetic parameters, r max and HCT. The r max was obtained from plots of time versus liver/heart activity ratios obtained in equal-area regions of interest over the heart and liver. The HCT was calculated from the hepatic clearance curve from plots of time versus liver activity. 99m Tc-MAG3-biocytin without bilirubin coinjection showed an r max of 8.9±1.3 and an HCT of 399±36 s. These values did not change even when 14 mg/kg of bilirubin were coinjected. By contrast, the parameters for 99m Tc-disofenin with bilirubin were significantly (p max was decreased from 7.9±2.5 to 1.4±0.2 and HCT was increased from 292±32 s to 782±133 s. 99m Tc-MAG3-biocytin hepatobiliary scintigraphy in mice is not affected by bilirubin coinjection, and this hepatobiliary agent appears to offer promise for estimating hepatic function in patients with high bilirubin levels

  10. Synthesis and animal experiment of 99mTc-labeled hepatobiliary imaging agents

    Zhou Xirui; Chen Shaoliang; Chen Guohui; Xu Qinfeng

    1993-01-01

    Six new compounds based on the principle of isosterism and hybridization had been synthesized. Methobrofenin was prepared by reduction of nitro mesitylene, followed by bromination and acylation with nitrilotriacetic acid. The 99m Tc-complexes of these compounds were prepared by stannous chloride reduction of sodium pertechnetate in aqueous solution. These labeled compounds, being similar to 99m Tc-mebrofenin, all were quick in the uptake by the liver cells, rapidly cleared off from the blood in mice, and had higher cumulative hepatobiliary excretion rates than Tc-99m-EHIDA

  11. Phantom and animal studies of a new hepatobiliary agent for MR imaging: comparison of Gd-DTPA-DeA with Gd-EOB-DTPA.

    Yoshikawa, Kohki; Inoue, Yusuke; Akahane, Masaaki; Shimada, Morio; Itoh, Sayaka; Seno, Atsushi; Hayashi, Sanshin

    2003-08-01

    To investigate the characteristics of Gd-DTPA-DeA as a hepatobiliary contrast agent for MR imaging in comparison with those of Gd-EOB-DTPA. We undertook phantom experiments to assess T1 relaxivity for Gd-DTPA-DeA, Gd-EOB-DTPA, and Gd-DTPA in human plasma. For Gd-DTPA-DeA and Gd-EOB-DTPA, we evaluated the contrast effect in rats using an SPGR sequence. The contrast ratios of liver and abdominal aorta were measured up to 21 minutes after intravenous administration of the agents. Visualization of the bile duct and renal pelvis was also assessed. In human plasma, T1 relaxivity was similar for Gd-DTPA-DeA and Gd-EOB-DTPA, and higher than those for Gd-DTPA. Whereas the contrast ratio of liver peaked about five minutes after the injection of Gd-EOB-DTPA and was followed by a subsequent decline, a continuous rise was shown for Gd-DTPA-DeA, resulting in a larger maximal contrast effect. Contrast ratios of the abdominal aorta were larger for Gd-DTPA-DeA. Biliary excretion was observed for both agents but occurred earlier with Gd-EOB-DTPA. While renal excretion was shown for all rats three minutes after the injection of Gd-EOB-DTPA, it was not observed for Gd-DTPA-DeA. Gd-DTPA-DeA may be used as a hepatobiliary contrast agent and shows different pharmacokinetics from Gd-EOB-DTPA. Copyright 2003 Wiley-Liss, Inc.

  12. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  13. Enhancements in hepatobiliary imaging: the spectrum of gadolinium-ethoxybenzyl diethylenetriaminepentaacetic acid usages in hepatobiliary magnetic resonance imaging.

    Channual, Stephanie; Pahwa, Anokh; Lu, David S; Raman, Steven S

    2016-09-01

    Gadolinium-ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) is a unique hepatocyte-specific contrast agent approved for clinical use in the United States in 2008. Gd-EOB-DTPA-enhanced MR has shown to improve detection and characterization of hepatic lesions. Gd-EOB-DTPA is now being routinely used in daily clinical practice worldwide. Therefore, it is important for radiologists to be familiar with the potential uses and pitfalls of Gd-EOB-DTPA, which extends beyond the assessment of focal hepatic lesions. The purpose of this article is to review the various usages of Gd-EOB-DTPA in hepatobiliary MR imaging.

  14. Gastroesophageal reflux demonstrated by hepatobiliary imaging in scleroderma

    Sawaf, N.W.; Orzel, J.A.; Weiland, F.L.

    1987-01-01

    Radionuclide hepatobiliary imaging was performed on a patient with a longstanding history of scleroderma who presented with abdominal pain suggestive of biliary disease. Cystic duct patency was documented after 10 min with tracer accumulation in the second portion of the duodenum which failed to progress consistent with the duodenal hypomotility of scleroderma. The patient was given intravenous Kinevac resulting in gastroesophageal reflux of radionuclide

  15. Gastroesophageal reflux demonstrated by hepatobiliary imaging in scleroderma

    Sawaf, N.W.; Orzel, J.A.; Weiland, F.L.

    1987-03-01

    Radionuclide hepatobiliary imaging was performed on a patient with a longstanding history of scleroderma who presented with abdominal pain suggestive of biliary disease. Cystic duct patency was documented after 10 min with tracer accumulation in the second portion of the duodenum which failed to progress consistent with the duodenal hypomotility of scleroderma. The patient was given intravenous Kinevac resulting in gastroesophageal reflux of radionuclide.

  16. Update on radionuclide imaging in hepatobiliary disease

    Rosenthall, L.

    1981-01-01

    The recent introduction of technetium Tc 99m-labeled acetanilide iminodiacetic acid (/sup 99m/Tc-IDA) analogues has facilitated the clincal study of the bile flow pathways. A variety of /sup 99m/Tc-IDA derivaties are under investigation. Basically all are metabolized by the hepatocyte and immediately thereafter excreted unconjugated into the biliary tract. Of the various derivatives tested, e.g., dimethyl (lidofenin), diethyl, paraisopropyl (iprofenin), parabutyl (butilfenin), and diisopropyl (disofenin), the last named is the best universal agent at this time. By serial liver imaging the patency of the cystic duct and the integrity of altered cholangiointestinal anatomy can be assessed, leakage of bile and gastric reflux can be disclosed, and medical and surgical jaundice can be distinguished

  17. Synthesis And Characterization Of Mebrofenin For Hepatobiliary Imaging

    Purwoko; Tamat, Swasono R.; Yunita, Fitri; Kristanti, Eti

    2003-01-01

    Mebrofenin labeled with Technetium-99m is a new radiopharmaceutical having superior and ideal characteristic as a hepatobiliary-imaging agent. The synthesis and characterization of Mebrofenin (3-Bromo-2,4,6-trimethyl acetanilido iminodiacetic acid) as IDA derivative has been carried out involving three steps of reaction i.e. : acetyllization of 2,4,6-Trimethyl aniline to get 2,4,6-trimethyl chloro acetanilide which upon bromination gives the intermediate bromotrimethyl derivative and [mally by nucleophilic substitution this intermediate product with iminodiacetic acid (IDA) gives mebrofenin. The acetylation and bromination reactions were carried out in acetic acid condition while the substitution was carried out by reflux for 5 hours in ethanol and water adjusted at pH 11. The ethanol was then removed under low pressure, and the unreacted compound was removed by filtration. The filtrate was adjusted to pH 2 - 2.5, and the resulting mebrofenin was isolated by filtration and recrystallized 3 times in ethanol. Characterization of the mebrofenin product was performed by observing its melting point (197-l99 o C), ultra violet and infra red spectra as well as mass spectrometric and high performance liquid chromatographic analysis. The results showed that the product was highly pure and the yield was around 20%

  18. Evaluation of hepatobiliary imaging using Tc-99m-DISIDA in hepatobiliary disease

    Kim, Yong Ga; Chung, Duck Soo; Kim, Ok Dong [Taegu Catholic Hospital, Daegu (Korea, Republic of)

    1985-06-15

    Hepatobiliary scintigraphy using Tc-labelled radiopharmaceuticals is employed primarily for the diagnosis of acute cholecystitis and for demonstration of biliary tract patency. We concluded a retrospective study of 55 patients with hepatobiliary disease from Jun. '84 to Sep. '84 at Taegu Catholic Hospital and tried to determine the etiology and find the possible differential points by analyzing the scintigraphic findings. The following results were obtained; 1. Tree-like photon defect on hepatic parenchyme was suggested characteristic of complete obstructive biliary disease, but could be seen in either benign or malignant etiology. 2. The grade of hepatocyte clearance was not useful in determining whether the cause of obstructive biliary disease was benign or malignant in this study. 3. Hepatocyte clearance was more severely impaired in hepatocellular disease than in obstructive biliary disease. 4. The photon defect in porta hepatis with complete biliary obstruction was suggested characteristic of common bile duct cancer. 5. The meniscus appearance at obstructed site of common bile duct was pathognomonic sign of choledocholithiasis. 6. When the gallbladder was not visualized, the differential diagnosis between acute and chronic cholecystitis was possible without delayed image by observing the transit time to bowel. The delayed transit to bowel was a favorable of chronic cholecystitis rather than of acute cholecystitis. 7. Acute pancreatitis could be easily differentiated from partial biliary obstruction by clinical and laboratory examination, but the finding of abrupt narrowing of pancreatic common bile duct with slight proximal dilatation on cholescintigraphy was also a key point in acute pancreatitis. 8. The segmental dilatation of intrahepatic duct was thought meaningful sign of clonorchiasis.

  19. Evaluation of hepatobiliary imaging using Tc-99m-DISIDA in hepatobiliary disease

    Kim, Yong Ga; Chung, Duck Soo; Kim, Ok Dong

    1985-01-01

    Hepatobiliary scintigraphy using Tc-labelled radiopharmaceuticals is employed primarily for the diagnosis of acute cholecystitis and for demonstration of biliary tract patency. We concluded a retrospective study of 55 patients with hepatobiliary disease from Jun. '84 to Sep. '84 at Taegu Catholic Hospital and tried to determine the etiology and find the possible differential points by analyzing the scintigraphic findings. The following results were obtained; 1. Tree-like photon defect on hepatic parenchyme was suggested characteristic of complete obstructive biliary disease, but could be seen in either benign or malignant etiology. 2. The grade of hepatocyte clearance was not useful in determining whether the cause of obstructive biliary disease was benign or malignant in this study. 3. Hepatocyte clearance was more severely impaired in hepatocellular disease than in obstructive biliary disease. 4. The photon defect in porta hepatis with complete biliary obstruction was suggested characteristic of common bile duct cancer. 5. The meniscus appearance at obstructed site of common bile duct was pathognomonic sign of choledocholithiasis. 6. When the gallbladder was not visualized, the differential diagnosis between acute and chronic cholecystitis was possible without delayed image by observing the transit time to bowel. The delayed transit to bowel was a favorable of chronic cholecystitis rather than of acute cholecystitis. 7. Acute pancreatitis could be easily differentiated from partial biliary obstruction by clinical and laboratory examination, but the finding of abrupt narrowing of pancreatic common bile duct with slight proximal dilatation on cholescintigraphy was also a key point in acute pancreatitis. 8. The segmental dilatation of intrahepatic duct was thought meaningful sign of clonorchiasis

  20. Renal enhancement and excretion of the hepatobiliary contrast agent Gd-EOB-DTPA

    Zangos, S.; Hammerstingl, R.; Mack, M.G.; Straub, R.; Engelmann, K.; Eichler, K.; Vogl, T.J.

    2001-01-01

    Purpose: To evaluate the clinical value of the renal clearance using MR imaging with different doses of gadolinium ethoxybenzyl-DTPA (Gd-EOB-DTPA) in comparison to gadolinium DTPA (Gd-DTPA). Material and Methods: In a double-blind and randomized clinical phase II study. MR imaging at 1.5 T was performed in 61 patients with five different doses of Gd-EOB-DTPA (3, 6, 12.5, 25 and 50 μmol/kg b.w. as a bolus injection). The study protocol comprised T 1 - and T 2 -weighted spin-echo magnetic resonance and two-dimensional fast low-angle shot imaging before and at increasing intervals for up to 45 min after injection of Gd-EOB-DTPA. These images were compared with Gd-DTPA-enhanced imaging (0.1 mmol/kg b. w. as a bolus injection). Results: After bolus injection of the hepatobiliary MR contrast agent Gd-EOB-DTPA a renal elimination was observed. Immediately after the injection of Gd-EOB-DTPA until the eighth minute a corticomedullary enhancement of the kidney was conspicuous. After the fourth minute a contrast enhancement could be seen in the renal pelvis. The best enhancement was noted after 20 minutes in the FLASH GRE and T 1 -weighted images with good pelvicaliceal contrast. After 45 minutes an outflow of Gd-EOB-DTPA into the ureter could be observed. Conclusion: In addition to the hepatobiliary secretion Gd-EOB-DTPA appears useful for the evaluation of renal structures and renal function on account of the renal excretion without diuretic preparation of the patients. (orig.) [de

  1. Delayed hepatobiliary imaging in the diagnosis of hepatocellular carcinoma

    Chen, S.; Ma, Z.; Tang, Z.

    2000-01-01

    In recent years, the use of ultrasonography (US), X-CT and MRI has reduced the employment of isotopic explorations in the detection of hepatocellular carcinoma (HCC). But sometime the results of US, X-CT or MRI were different and diagnosis was very difficult. This present investigation was aimed to assess the usefulness of delayed hepatobiliary imaging in the diagnosis of HCC in these patients. Forty-eight patients consisting of 33 males and 15 females were entered into the research protocol. The mean age was 46 yr old (range 12-71 yr old). All of the patients were performed by surgery and verified histologically after nuclear examination. The subject was in a supine position under a gamma camera (Elscint, Apex Ap-6) and 555 MBq of Tc-99m-PMT were injected intravenously. The initial scinphotos obtained within 1 min after injection were used to image the blood pool phase. Subsequently, hepatic scans were obtained at 5 min, 1,2 and 5 hr. Anterior, right lateral and posterior hepatic images were recorded. According to the radioactive uptake by the lesion in delayed phase, the negative (no or minor uptake), positive (equal or greater uptake) or very strong positive (almost equal to the activity, of gallbladder) were judged. The positive were considered as diagnostic of HCC. And the very strong positive, were considered as diagnostic of benign hepatoma, such as adenoma or FNH. Thirty-seven of the forty-eight patients were HCC based on histology. Delayed imaging revealed increased or equilibrated uptake of radioactivity by the tumors in 22 of 37 patients with hepatocellular carcinoma. The sensitivity was 59.5%. One patient final diagnosis based on histology was focal nodular regenerative hyperplasia, and only the diagnosis with delayed hepatobiliary imaging before surgery was correct. Compared with US, X-CT and MRI, delayed hepatobiliary imaging had the highest specificity for diagnosis of hepatocellular carcinoma. In recent group, the specificity of Tc-99m-PMT delayed

  2. Diagnostic imaging in the study of human hepatobiliary fascioliasis.

    Cantisani, V; Cantisani, C; Mortelé, K; Pagliara, E; D'Onofrio, M; Fernandez, M; D'Ambrosio, U; Lombardi, V; Marigliano, C; Ricci, P

    2010-02-01

    Fascioliasis is a rare zoonotic disease caused by the trematode Fasciola hepatica. We present the typical patterns of hepatobiliary fascioliasis observed in ten patients studied with multimodality imaging. Between 2002 and 2005, ten women with fascioliasis were admitted to the Brigham and Women's Hospital, Harvard Medical School (BWH), with abdominal pain and mild fever. All imaging modalities, including ultrasound (US), computed tomography (CT), magnetic resonance (MR) imaging (n = 2) and endoscopic retrograde cholangiopancreatography (ERCP) (n = 1) were reviewed by two expert radiologists working in consensus. In all patients (10/10, 100%), US showed parenchymal heterogeneity characterised by multiple subcapsular and peribiliary hypoechoic nodular lesions that were ill-defined and coalesced into tubular or tortuous structures. In six patients (6/10, 60%), the lesions appeared hypoechoic, whereas in four patients (4/10, 40%), there was an alternation of hyperechoic and hypoechoic nodules. On CT, all patients (10/10, 100%) showed hypodense patchy lesions in subcapsular, peribiliary or periportal locations, which coalesced to form tubular structures and were more evident during the portal phase. Lesion diameter ranged from 2 cm to 7 cm. Capsular enhancement was seen in four cases on CT (4/10, 40%) and in one also at MR imaging. MR imaging, performed in two patients, confirmed the presence of the lesions, which appeared hyperintense on T2-weighted images and were characterised by mild peripheral enhancement after gadolinium administration. Four patients had gallbladder wall thickening (4/10, 40%), with parasites in the gallbladder lumen. Although rare, hepatobiliary fascioliasis should be considered in the differential diagnosis in the appropriate clinical scenario, especially in patients coming from endemic areas. The typical imaging pattern of fascioliasis is the presence of subcapsular, peribiliary or periportal nodules that are usually ill-defined and coalesce

  3. Specific diagnosis of hepatocellular carcinoma by delayed hepatobiliary imaging

    Hasegawa, Y.; Nakano, S.; Ibuka, K.

    1986-01-01

    For assessment of the value of delayed hepatobiliary imaging with technetium 99m (/sup 99m/Tc)-(Sn)-N-pyridoxyl-5-methyltryptophan (/sup 99m/Tc-PMT) for specific diagnosis of hepatocellular carcinoma, 88 patients with various malignant and benign liver diseases (49 with hepatocellular carcinoma, 4 with cholangiocellular carcinoma, 10 with metastatic liver carcinoma, 2 with liver cysts, 2 with liver hemangioma, 1 with liver abscess, 2 with intrahepatic lithiasis, 12 with liver cirrhosis, and 6 with chronic hepatitis) were studied. In 20 (41%) of the 49 patients with hepatocellular carcinoma, greater uptake of /sup 99m/Tc-PMT by the tumor than by the surrounding liver tissue was seen in delayed hepatobiliary images, whereas in eight patients (16%), equilibrated uptake was seen. No increased uptake of the radioisotope by hepatic lesions was seen in 21 patients with localized liver diseases other than hepatoma. Moreover, in 18 patients with diffuse liver diseases, no focal accumulation of the radioisotope was seen in delayed /sup 99m/Tc-PMT images. In addition, of 28 patients with hepatocellular carcinoma in whom the serum alpha-fetoprotein level showed little or no increase, 12 showed increased uptake of /sup 99m/Tc-PMT by the tumor. In assessing delayed /sup 99m/Tc-PMT images, however, it was necessary to consider following complications: accumulation of tracer in obstructed and dilated biliary trees; retention of radioactivity in nonneoplastic liver tissues; difficulties in evaluating /sup 99m/Tc-PMT uptake by small hepatic tumors; overlapping of radioactivity in the gut and gallbladder in delayed /sup 99m/Tc-PMT images of tumors. This study indicates that delayed /sup 99m/Tc-PMT images can be useful in the diagnosis of hepatocellular carcinoma

  4. Hepatobiliary fascioliasis

    Andrade, Daniel Ramos; Andrade, Luísa; Antunes, Célia; Donato, Paulo; Semedo, Luís Curvo; Alves, Filipe Caseiro

    2017-01-01

    Hepatobiliary fascioliasis is a parasitic disease caused by Fasciola hepatica, which is a trematode that primarily infects cattle and sheep, but may also affect humans in endemic areas.There are two phases of the disease: the acute one - where the parasites infect the liver parenchyma; and the subacute / chronic phase - when the parasites reach the biliary ducts and gallbladder, providing typical imaging findings.Because this disease may mimic several hepatobiliary disorders, misdiagnosis or ...

  5. Phenolic aminocarboxylate chelates of 99mTc as hepatobiliary agents.

    Hunt, F C; Maddalena, D J; Wilson, J G; Bautovich, G J

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[o-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with 99mTc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, 99mTc-Br-EDDHA and 99mTc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of 99mTc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile.

  6. Phenolic aminocarboxylate chelates of sup(99m)Tc as hepatobiliary agents

    Hunt, F.C.; Maddalena, D.J.; Wilson, J.G.; Bautovich, G.J.

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[omicron-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with sup(99m)Tc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, sup(99m)Tc-Br-EDDHA and sup(99m)Tc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of sup(99m)Tc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile. (author)

  7. Evaluation of the hepatobiliary function with 99mTc-EHIDA imaging during total parenteral nutrition

    Zhou Qian; Jiang Zhouming; Yang Meifang

    1988-01-01

    14 surgical patients with non-hepatobiliary diseases were studied with 99m Tc-EHIDA imaging to evaluate the effect of total parenteral nutrition (TPN) on the hepatobiliary function. Duration of TPN ranged from 6-56 days, 10 of the 14 patients Beijing within 10 days. The results showed that: (1) 11 of 14 patients had abnormal scintigraphic features. The most prominet findings were delayed liver excretion and prolonged blood clearance time. This fact suggests that not only the rate of excretion of the bile from the liver is decreased but the uptake ability of the hepatorcyte is also impaired. (2) The effect of TPN on liver function is reversible. It was concluded that in order to prevent irreversible damage of hepatobiliary function caused by TPN, the duration of TPN should not be too long and oral intake of nutrients should be resumed as soon as possible

  8. Hepatobiliary cystadenoma exhibiting morphologic changes from simple hepatic cyst shown by 11-year follow up imagings

    Sato Koichi

    2008-12-01

    Full Text Available Abstract Background A long-term follow up case of hepatobiliary cystadenoma originating from simple hepatic cyst is rare. Case presentation We report a case of progressive morphologic changes from simple hepatic cyst to hepatobiliary cystadenoma by 11 – year follow up imaging. A 25-year-old man visited our hospital in 1993 for a simple hepatic cyst. The cyst was located in the left lobe of the liver, was 6 cm in diameter, and did not exhibit calcification, septa or papillary projections. No surgical treatment was performed, although the cyst was observed to gradually enlarge upon subsequent examination. The patient was admitted to our hospital in 2004 due to epigastralgia. Re-examination of the simple hepatic cyst revealed mounting calcification and septa. Abdominal CT on admission revealed a hepatic cyst over 10 cm in diameter and a high-density area within the thickened wall. MRI revealed a mass of low intensity and partly high intensity on a T1-weighted image. Abdominal angiography revealed hypovascular tumor. The serum levels of AST and ALT were elevated slightly, but tumor markers were within normal ranges. Left lobectomy of the liver was performed with diagnosis of hepatobiliary cystadenoma or hepatobiliary cystadenocarcinoma. The resected specimen had a solid component with papillary projections and the cyst was filled with liquid-like muddy bile. Histologically, the inner layer of the cyst was lined with columnar epithelium showing mild grade dysplasia. On the basis of these findings, hepatobiliary cystadenoma was diagnosed. Conclusion We believe this case provides evidence of a simple hepatic cyst gradually changing into hepatobiliary cystadenoma.

  9. Development of a novel fusion imaging technique in the diagnosis of hepatobiliary-pancreatic lesions

    Soga, Koichi; Ochiai, Jun; Miyajima, Takashi; Kassai, Kyoichi; Itani, Kenji; Yagi, Nobuaki; Naito, Yuji

    2013-01-01

    Multi-row detector computed tomography (MDCT) and magnetic resonance cholangiopancreatography (MRCP) play an important role in the imaging diagnosis of hepatobiliary-pancreatic lesions. Here we investigated whether unifying the MDCT and MRCP images onto the same screen using fusion imaging could overcome the limitations of each technique, while still maintaining their benefits. Moreover, because reports of fusion imaging using MDCT and MRCP are rare, we assessed the benefits and limitations of this method for its potential application in a clinical setting. The patient group included 9 men and 11 women. Among the 20 patients, the final diagnoses were as follows: 10 intraductal papillary mucinous neoplasms, 5 biliary system carcinomas, 1 pancreatic adenocarcinoma and 5 non-neoplastic lesions. After transmitting the Digital Imaging and Communication in Medicine data of the MDCT and MRCP images to a workstation, we performed a 3-D organisation of both sets of images using volume rendering for the image fusion. Fusion imaging enabled clear identification of the spatial relationship between a hepatobiliary-pancreatic lesion and the solid viscera and/or vessels. Further, this method facilitated the determination of the relationship between the anatomical position of the lesion and its surroundings more easily than either MDCT or MRCP alone. Fusion imaging is an easy technique to perform and may be a useful tool for planning treatment strategies and for examining pathological changes in hepatobiliary-pancreatic lesions. Additionally, the ease of obtaining the 3-D images suggests the possibility of using these images to plan intervention strategies.

  10. Phenolic aminocarboxylate chelates of sup(99m)Tc as hepatobiliary agents

    Hunt, F.C.; Maddalena, D.J.; Wilson, J.G.; Bautovich, G.J.

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di(omicron-hydroxyphenylacetic acid) (EDDHA) and N,N'-bis(2-hydroxybenzyl) ethylenediamine N,N'-diacetic acid (HBED) were complexed with sup(99m)Tc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, sup(99m)Tc-Br-EDDHA and sup(99m)Tc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of sup(99m)Tc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile.

  11. Diagnostic imaging of digestive tract involvement in cystic fibrosis. Part 1: hepatobiliary disease

    Miralles, M.; Gonzalez, G.; Serrano, C.; Manzanares, J.; Berrocal, T.

    1998-01-01

    Cystic fibrosis is a severe hereditary disease characterized by epithelial chloride channel dysfunction, leading to the production of abnormally thick secretions. The abnormal gene is located on the long arm of chromosome 7. Hepatobiliary involvement derives from ductal obstruction causing cholestasis, steatosis, cirrhosis and portal hypertension. Biliary sludge, cholelithiasis and gallbladder sclerosis and atrophy are common findings. As the correlation between the hepatobiliary changes and their clinical and analytical impact is very limited, imaging techniques are essential in this disease. Ultrasound is the basic imaging tool, both for initial evaluation and follow-up of the hepatic and biliary involvement, although other techniques such as radionuclide imaging, magnetic resonance and computed tomography can be highly useful. Given the long-term, chronic nature of this disease, the use of aggressive techniques or irradiation should be carefully weighed. (Author) 38 refs

  12. 99Tcm-MIBI hepatobiliary scintigraphy in peadiatric patients with severe cholestatic infant hepatitis syndrome

    Chen Guibing; Huang Jinxiong; He Xiaojiang; Luo Zuoming; Lu Zhengyuan; Wu Hua

    2010-01-01

    Objective: Because of the limited of 99 Tc m -diethyl iminodiacetic acid ( 99 Tc m -EHIDA) hepatobiliary scintigraphy in the diagnosis of severe cholestatic infant hepatitis syndrome, trial use 99 Tc m -methoxy isobutyl isonitrile ( 99 Tc m -MIBI) as a new hepatobiliary scintigraphy imaging agent to understand its applied basis and primary evaluate value in diagnosis of severe cholestatic infant hepatitis syndrome. Methods: constructed choledochal atresia animal model and investigated the application basis of 99 Tc m -MIBI hepatobiliary scintigraphy. Twenty-seven children patients of severe cholestatic who finally confirmed infant hepatitis syndrome were underwent firstly 99 Tc m -EHIDIA hepatobiliary scintigraphy. After 24 h delay imaging next day, 99 Tc m -MIBI hepatobiliary scintigraphy was underwent after 1 h. Two imaging agents of value in the diagnosis of severe cholestatic infant hepatitis syndrome were compared. Results: It was proved that 99 Tc m -MIBI was surely excreted by hepatobiliary and had no intestinal autocrine phenomenon in animal test. So 99 Tc m -MIBI can be used to undergo hepatobiliary scintigraphy. The sensitivity of 99 Tc m -MIBI hepatobiliary scintigraphy in the diagnosis of severe cholestatic infant hepatitis syndrome was 100% in our primary clinical study. Its sensitivity was higher than which of 99 Tc m -EHIDA hepatobiliary scintigraphy (66.67%) by far. Conclusion: With regard to those children patients who suspected highly severe cholestatic infant hepatitis syndrome in clinical, the sensitivity of 99 Tc m -MIBI hepatobiliary scintigraphy is obviously superior to conventional 99 Tc m -EHIDA hepatobiliary scintigraphy. (authors)

  13. Ruthenium-97 hepatobiliary agents for delayed studies of the bilary tract I: Ru-97 PIPIDA: concise communication

    Schachner, E.R.; Gil, M.C.; Atkins, H.L.; Som, P.; Srivastava, S.C.; Badia, J.; Sacker, D.F.; Fairchild, R.G.; Richards, P.

    1981-01-01

    Failure of early diagnosis of biliary atresia results in the development of cirrhosis and death. Commonly used hepatobiliary agents are not ideal for follow-up studies because of their unfavorable physical properties or short half-life. The excellent physical properties of Ru-97 should overcome these limitations. Therefore, Ru-97 PIPIDA (N,α-(p-isopropyl acetanilide) iminoacetic acid) is being investigated as a potential hepatobiliary agent that would allow an improved diagnosis of the disease. Ruthenium-97 PIPIDA and Tc-99m PIPIDA showed similar blood clearance rates in dogs. Ru-97 PIPIDA scintigrams in dogs showed early uptake in liver and gallbladder and slow excretion through the gastrointestinal tract. Biodistribution studies were performed in normal rats and rats with biliary obstruction. The findings suggest that Ru-97 PIPIDA should be useful for delayed studies ( 1 to 3 days) of the biliary tract

  14. Evaluation gallbladder function in patients with spinal cord injury using 99Tcm-DISIDA hepatobiliary imaging

    Xia Changsuo; Li Hong; Hong Guangxiang

    2005-01-01

    Objective: To investigate gallbladder function in patients with spinal cord injury (SCI). Methods: Eighteen normal control subjects, 16 other traumatic control subjects and 46 SCI patients were include. Gallbladder function was quantitatively evaluated by 99 Tc m labeled imino-diacetic acid analogue (DISIDA) hepatobiliary imaging using two parameters as filling fraction (FF) and ejection fraction (EF). The gallbladder function of SCI patients was further analyzed according to age, sex, body weight, injury gradient (with ASIA criteria), cord injury level and the duration of injury. Results: 52% of SCI patients had abnormal FF and 59% with abnormal EF. Significantly decreased FF and EF values were found in SCI patients, especially in those who were female, severe and high-level injuries of spinal cord. Conclusion: With the use of quantitative 99 Tc m -DISIDA hepatobiliary imaging, significant impairment of the gallbladder function was found in SCI patients. (authors)

  15. Liver cysts associated with polycystic kidney disease: Role of Tc-99m hepatobiliary imaging

    Salam, M.; Keeffe, E.B.

    1989-01-01

    A 42-year-old woman with multiple hepatic cysts associated with autosomal polycystic kidney disease was evaluated for abdominal discomfort and new liver test abnormalities following blind aspirations of her liver cysts. Tc-99m mebrofenin hepatobiliary imaging revealed a markedly enlarged liver with multiple photon deficient areas, focal retention of isotope in the left hepatic ductal system, no accumulation of radionuclide in cysts, and an unusual medial gallbladder position. Endoscopic retrograde cholangiography confirmed all of these findings. Abdominal discomfort and liver biochemical abnormalities were attributed to cyst compression of nearby structures, including bile ducts. Hepatobiliary imaging is useful to exclude communication of bile ducts with hepatic cysts, to detect incidental abnormalities such as partial bile duct obstruction, and to distinguish the gallbladder from nearby hepatic cysts

  16. 99Tcm-EHIDA hepatobiliary imaging for neonatal intrahepatic cholestasis caused by citrin deficiency

    Gong Jian; Deng Mei; Song Yuanzong; Xu Hao

    2012-01-01

    Objective: To evaluate the imaging characteristics of 99 Tc m -EHIDA hepatobiliary scintigraphy in neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD). Methods: 99 Tc m -EHIDA hepatobiliary scan was performed on 12 NICCD infants (aged (127 ±27) d) and 5 infants as a control group (including 4 cases with hepatitis syndrome and 1 with abnormal lipid metabolism, aged (164 ± 15) d). The differences of hepatic activity retention time and bowel activity visualization time between the two groups were observed. The two-sample Wilcoxon rank sum test was used to analyze the data. Results: In the NICCD group, both hepatic activity retention time and bowel activity visualization time were 180-1440 min (median=360 min). In the control group, hepatic activity retention time and bowel activity visualization time were 60-180 min (median=60 min) and 15-30 min (median=15 min), respectively. The differences of hepatic activity retention time and bowel activity visualization time between the two groups were statistically significant (Z=-3.20 and -3.17, both P<0.05). Three NICCD infants showed minimal hepatic uptake of the tracer. The bowel activity was not visible in 1 NICCD case.The hepatic uptake and biliary excretion function of this infant were significantly improved on hepatobiliary scintigraphy after treatment, with a bowel activity visualization time of 15 min. Conclusion: NICCD infants show impaired hepatic uptake and biliary excretion function on 99 Tc m -EHIDA hepatobiliary imaging, which may be used in NICCD diagnosis and treatment response evaluation. (authors)

  17. Comparison of gadolinium Cy2DOTA, a new hepatobiliary agent, and gadolinium HP-DO3A, an extracellular agent, in healthy liver and metastatic disease

    Runge, V.M.; Wells, J.W.; Williams, N.M.

    1995-01-01

    A new gadolinium (Gd) chelate with preferential hepatobiliary uptake, Gd Cy 2 DOTA, was compared in two animal species with Gd HP-DO3A (gadoteridol), a clinically approved contrast agent with extracellular distribution. Liver enhancement was evaluated for these two contrast agents using magnetic resonance imaging, whereas an experimental model of metastatic disease was used to evaluate the agents' efficacy for liver-lesion delineation. The two agents were compared in four healthy Rhesus monkeys (eight studies) and five New Zealand White rabbits with implanted VX-2 liver tumors (ten studies). The contrast dose was 0.1 mmol/kg, with the agents given in random order and at least 72 hours between contrast injections. Breathhold T1-weighted spin echo scans were obtained at 1.5 tesla (T) before and after contrast was administered. Postcontrast scans were obtained 1 to 90 minutes after injection in the monkeys and 1 to 240 minutes after injection in the rabbits. Prolonged hepatic enhancement, superior in degree to that with Gd HP-DO3A, was noted to both monkeys and rabbits after injection of Gd Cy 2 DOTA. Two minutes after contrast, liver SI was 1.94 ± 0.05 with Gd Cy 2 DOTA compared with 1.5 ± 0.05 with Gd HP-DO3A in monkeys. Sixty minutes after contrast, liver SI was 1.60 ± 0.09 compared with 1.20 ± 0.02. The difference between agents was significant at all times from 2 to 60 minutes after contrast injection (P 2 DOTA but not with Gd HP-DO3A. The maximum improvement in lesion conspicuity (rabbit) occurred 45 minutes after injection of Gd Cy 2 DOTA and 5 minutes after injection of Gd HP-DO3A. 22 refs., 12 figs

  18. Structure-activity studies on 99mTc phenolic aminocarboxyllic acid hepatobiliary agente

    Maddalena, D.J.; Wilson, J.G.; Snowdon, G.M.

    1987-01-01

    Biodistributions of a series of eight 99m Tc hydroxybenzylsarcosine (HBS) complexes were carried out in rats and their urinary and hepatobiliary excretion compared with their lipophilicities, the influence of substituent on the phenyl ring and plasma protein binding ability. The charge on the complexes was determined by electrophoresis at varying pH values. The HBS derivatives formed anionic complexes with 99m Tc that excreted mainly via the urinary route. An increase in the lipophilicity of the complexes by substitution of halogens onto the phenyl ring led to an increase in serum protein binding and a decrease in the urinary output but hat no direct effect on hepatobiliary output. (Author) [es

  19. MR imaging evaluation of pancreas and hepatobiliary system in cystic fibrosis

    Murayama, S.; Robinson, A.E.; Stallworth, J.; Mulvihill, D.; Beckerman, R.; Davis, S.

    1988-01-01

    The pancreas and hepatobiliary system of 20 patients with cystic fibrosis were analyzed with a 1.5-T magnet. T1-weighted, T2-weighted, and proton-density images were obtained, and the T1 and T2 values of the pancreas were calculated. Signal intensity ratios were calculated for the signal intensities of the pancreas and the liver relative to that of muscle and fat on each pulse sequence. Fatty replacement of the pancreas and regenerating nodules of biliary cirrhosis were readily identified on T1-weighted images. The T1 values for pancreatic tissue showed promise as a good marker for pancreatic disease progression. Pancreas-to-fat signal intensity ratios on 300/20 (repetition time msec/echo time msec) and 2,000/75 images were considered to be a good standard for evaluating the level of pancreatic involvement

  20. Characteristic MR and CT imaging findings of hepatobiliary paragonimiasis and their pathologic correlations

    Lu, Chunyan; Hu, Yajun; Chen, Weixia [Dept of Radiology, West China Hospital of Sichuan Univ., Sichuan (China)], e-mail: wxchen25@126.com

    2012-06-15

    Background: Hepatobiliary paragonimiasis (HP) is not commonly encountered and may be confused with hepatobiliary tumors; however, computed tomography (CT) and magnetic resonance imaging (MRI) features of HP allow this entity to be distinguished from other diseases. Purpose: To present the CT and MRI findings in patients with HP and to describe some specific imaging findings along with their pathological correlations. Material and Methods: Imaging and clinical findings of 21 patients (9 boys/men and 12 girls/women; age range 3-67 years; mean age 40 years) who were diagnosed with HP were retrospectively evaluated. Among these patients, 16 underwent CT examination only, two had MR examination only, and three underwent both CT and MR. All patients underwent surgery, and the HP diagnosis was confirmed by the surgical and histopathologic results. Results: Chronic abdominal pain or back pain was reported by 14 patients, severe abdominal pain with acute onset was reported by one patient, and six patients were asymptomatic and were discovered incidentally. Peripheral eosinophilia was present in 14 patients (14/21, 66.7%), and abnormal liver function tests were found in 16 patients (16/21, 76.2%). Of the 19 patients who underwent CT imaging, 17 patients showed multiple mixed hypodense lesions or multiple cysts with inlaying septation with separate irregular rims or circular enhancement on post-contrast CT images. Tunnel-shaped micro abscesses and necrotic cavities were found in the lesions of 12 of those 17 patients. The other two patients showed smaller cystic masses. MRI showed faveolate T1 hypointense and T2 hyperintense areas in the liver parenchyma with rim or peripheral enhancement. Nodular or circular hyperintense materials were found scattered in the lesions on T1-weighted imaging. Conclusion: CT and MRI can reveal the radiological-pathological features of HP. Together with laboratory findings, MRI and CT findings may provide diagnostic clues, especially in endemic

  1. Characteristic MR and CT imaging findings of hepatobiliary paragonimiasis and their pathologic correlations

    Lu, Chunyan; Hu, Yajun; Chen, Weixia

    2012-01-01

    Background: Hepatobiliary paragonimiasis (HP) is not commonly encountered and may be confused with hepatobiliary tumors; however, computed tomography (CT) and magnetic resonance imaging (MRI) features of HP allow this entity to be distinguished from other diseases. Purpose: To present the CT and MRI findings in patients with HP and to describe some specific imaging findings along with their pathological correlations. Material and Methods: Imaging and clinical findings of 21 patients (9 boys/men and 12 girls/women; age range 3-67 years; mean age 40 years) who were diagnosed with HP were retrospectively evaluated. Among these patients, 16 underwent CT examination only, two had MR examination only, and three underwent both CT and MR. All patients underwent surgery, and the HP diagnosis was confirmed by the surgical and histopathologic results. Results: Chronic abdominal pain or back pain was reported by 14 patients, severe abdominal pain with acute onset was reported by one patient, and six patients were asymptomatic and were discovered incidentally. Peripheral eosinophilia was present in 14 patients (14/21, 66.7%), and abnormal liver function tests were found in 16 patients (16/21, 76.2%). Of the 19 patients who underwent CT imaging, 17 patients showed multiple mixed hypodense lesions or multiple cysts with inlaying septation with separate irregular rims or circular enhancement on post-contrast CT images. Tunnel-shaped micro abscesses and necrotic cavities were found in the lesions of 12 of those 17 patients. The other two patients showed smaller cystic masses. MRI showed faveolate T1 hypointense and T2 hyperintense areas in the liver parenchyma with rim or peripheral enhancement. Nodular or circular hyperintense materials were found scattered in the lesions on T1-weighted imaging. Conclusion: CT and MRI can reveal the radiological-pathological features of HP. Together with laboratory findings, MRI and CT findings may provide diagnostic clues, especially in endemic

  2. Radioiodinated Rhodamine-123: a potential cationic hepatobiliary imaging agent

    Moonen, P.; Gorree, G.C.M.; Hoekstra, A.

    1987-01-01

    The labelling of the cationic dye Rhodamine-123 with 125 I is described. The biodistribution of the iodinated Rhodamine-123 has been determined at different time intervals after intravenous injection into fasted rats. It turned out that the dye is predominantly cleared by the liver and discharged into the bile. The bile acid taurocholate did not enhance the rate of excretion of 125 I-Rhodamine-123. (author)

  3. Pharmacokinetics of hepatobiliary imaging agents in rats: concise communication

    Smith, R.B.; Coupal, J.; DeLand, F.H.; Triplett, J.W.

    1979-01-01

    The distribution and elimination kinetics of Tc-99m pyridoxylidene glutamate (Tc-99m PG), of Tc-99m N-(2,6-dimethyl-phenylcarbamoylmethyl)iminodiacetic acid (Tc-99m HIDA), and of I-131 rose bengal in blood were quantitated after i.v. injection in rats. This was performed by use of a unique indwelling catheter that externalizes the systemic circulation, permitting continuous monitoring of blood radioactivity. The blood activity-time curves of Tc-99m PG and Tc-99m HIDA are described by the sum of three exponential functions. Only two exponentials are required in the case of I-131 rose bengal. The rank order for the rates of loss from blood was Tc-99m HIDA > Tc-99m PG > I-131 rose bengal. Bile was collected after administration of Tc-99m HIDA and Tc-99m PG. The total excretion of radioactivity over a 70-min period amounted to 65.7% and 42.8% of the dose of Tc-99m HIDA and Tc-99m PG, respectively. A linear compartmental kinetic model was developed to account for the disappearance from blood and the biliary excretion of these radiopharmaceuticals in rats

  4. Added value of Gd-EOB-DTPA-enhanced Hepatobiliary phase MR imaging in evaluation of focal solid hepatic lesions

    Haimerl, Michael; Wächtler, Max; Platzek, Ivan; Müller-Wille, Rene; Niessen, Christoph; Hoffstetter, Patrick; Schreyer, Andreas Georg; Stroszczynski, Christian; Wiggermann, Philipp

    2013-01-01

    Correct characterization of focal solid hepatic lesions has always been a challenge and is of great diagnostic and therapeutic relevance. The purpose of this study was to determine the added value of hepatobiliary phase images in Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) for differentiating focal solid hepatic lesions. In this retrospective trial 84 consecutive patients underwent Gd-EOB-DTPA-enhanced MR examinations. MRI was conducted for 64 patients with malignant focal hepatic lesions (34 hepatocellular carcinoma (HCC), 30 metastases) and for 20 patients with benign hepatic lesions (14 focal nodular hyperplasia (FNH), 3 adenoma, 3 hemangioma). Five radiologists independently reviewed three sets of MR images by means of a 5-point confidence scale from score 1 (definitely benign) to score 5 (definitely malignant): set 1: unenhanced images; set 2: unenhanced and Gd-EOB-DTPA-enhanced dynamic images; set 3: hepatobiliary phase images in addition to set 2. Accuracy was assessed by the alternative free-response receiver operating characteristic curve (A z ) and the index of diagnostic performance was calculated. Diagnostic accuracy was significantly improved by the addition of Gd-EOB-DTPA-enhanced dynamic images: A z in set 1 was 0.708 and 0.833 in set 2 (P = 0.0002). The addition of hepatobiliary phase images increased the A z value to 0.941 in set 3 (set 3 vs set 2, P < 0.0001; set 3 vs set 1, P < 0.0001). The index of diagnostic performance was lowest in set 1 (45%), improved in set 2 (71%), and highest in set 3 (94%). Hepatobiliary phase images obtained after Gd-EOB-DTPA-enhanced dynamic MRI improve the differentiation of focal solid hepatic lesions

  5. Hepatobiliary scintigraphy

    Velchik, M.G.

    1988-01-01

    This chapter describes the role of nuclear medicine in the evaluation of the hepatobiliary system. The technical aspects of hepatobiliary scintigraphy, or cholescintigraphy (radiopharmaceutical, radiation dosimetry, instrumentation, and method) are briefly presented, followed by a discussion of each of the indications for such examination. Its relative advantages and disadvantages with respect to alternative radiographic examinations are emphasized. Logical, efficient, cost-effective sequences of diagnostic studies are recommended whenever appropriate in order to derive the maximum information with the least time and expense. It is hoped that the reader will come away with an appreciation of the type of diagnostic information provided by hepatobiliary scintigraphy, its accuracy, its application in the workup of the patient with hepatobiliary disease, and its strengths and limitations compared with other radiologic studies

  6. Hepatobiliary scanning

    Verdegaal, W P

    1978-01-01

    The use of hepatobiliary scintigraphy is discussed on the basis of personal observations with sup(99m)Tc-pyridoxylideneglutamate (sup(99m)Tc-PG). Hepatobiliary scintigraphy appears to be a useful tool in differentiating the causes of jaundice. Its value as a test for biliary reflux to the stomach and as a method to evaluate the function of intestinal and bilidigestive anastomoses needs further investigation.

  7. Preparation of N-(3-BROMO-2,4,6-trimethylacetanilide) iminodiacetic acid and its 99MTc-complex for hepatobiliary imaging

    Choi, Ok Ja; Hong, Young Don; Gwon, Hui Jeong; Choi, Sang Mu; Choi, Sun Ju

    2005-01-01

    N-(3-bromo-2,4,6-trimethylacetanilide) iminodiacetic acid (BrTIDA) was synthesized using nitrilotriacetic anhydride prepared in situ, and lyophilized vials were prepared which contained 20 mg of BrTIDA and 0.4 mg of SnCl 2 . To evaluate the clinical efficacy of the in-house prepared lyophilized kit, a technetium-99m complex of BrTIDA was prepared; its in vivo pharmacokinetic behavior was evaluated via animal studies to assess the hepatocytic function and the functional status of the cystic duct and the gallbladder. Serial static image scans of rabbits and the biodistribution in mice injected with 99m Tc-BrTIDA revealed that none of the tissues except for the hepatobiliary system showed radioactivity concentrations, and a rapid clearance from the organs was observed. In conclusion, a lyophilized kit and its prepared 99m Tc-BrTIDA can be applied as a hepatobiliary imaging agent for the evaluation of the functional status of the hepatocytes and the patency of the biliary duct

  8. Labeling of ursodeoxycholic acid with technetium-99m for hepatobiliary imaging

    Sanad, M.H.; El-Tawoosy, M.

    2013-01-01

    An adopted method for the preparation of high radiochemical purity 99m Tc-ursodeoxycholic acid (UDCA) was conducted with a high radiochemical yield up to 97.5 %. The reaction proceeds well using 2 mg UDCA, 50 μg tin chloride in solution of pH 8 at room temperature for 30 min. The radiochemical yield was up to 97.5 % as pure as 99m Tc-UDCA. Different chromatographic techniques (paper chromatography and electrophoresis) were used to evaluate the radiochemical yield and purity of the labeled product. Biodistribution studies were carried out in Albino Swiss mice at different time intervals after administration of 99m Tc-UDCA. The uptake of 99m Tc-UDCA in the liver gave the chance to diagnose it. The results indicate that the labeled compound cleared from the systematic circulation within 2 h after administration and majority of organs showed significant decrease in uptake of 99m Tc-UDCA. Finally, the liver uptake was high and the results indicate the possibility of using 99m Tc-UDCA for hepatobiliary imaging.

  9. {sup 99m}Tc sestamibi imaging. Can it be a useful substitute for hepatobiliary scintigraphy in infantile jaundice?

    Sadeghi, R.; Kakhki, V.R.D.; Zakavi, R. [Mashhad Univ. of Medical Sciences (Iran). Nuclear Medicine Dept.; Kianifar, H.R. [Mashhad Univ. of Medical Sciences (Iran). Paediatric Dept.; Ansari, K. [Tehran Univ. of Medical Sciences (Iran). Nuclear Medicine Dept.

    2009-07-01

    Hepatobiliary scintigraphy is an integral part in the diagnostic work-up of the neonatal cholestasis syndrome. However, less than optimal specificity is its major disadvantage. Differentiation between biliary atresia and neonatal hepatitis is nearly impossible in some cases with poor hepatocellular function. {sup 99m}Tc sestamibi (MIBI) is a cationic lipophilic agent which is a substrate of P-glycoprotein. This glycoprotein is normally expressed in biliary canalicular surfaces of hepatocytes. This property provides a hepatic excretory mechanism which is different from bilirubin excretion. In this study we evaluated the value of {sup 99m}Tc MIBI in differential diagnosis of neonatal cholestasis. 20 infants with a mean age of 2.41 months (range, 0.1-5 months) were included in the study. Ten infants turned out to have extrahepatic biliary atresia and the other ten had neonatal hepatitis. Hepatobiliary (with {sup 99m}Tc BrIDA) and {sup 99m}Tc MIBI scintigraphy were performed for all the patients. {sup 99m}Tc MIBI scintigraphy has shown bowel activity in all patients, including the patients with biliary atresia. Hepatobiliary scintigraphy revealed bowel activity only in five patients with neonatal hepatitis. Bowel visualization with {sup 99m}Tc MIBI may be seen in patients with biliary atresia and {sup 99m}Tc MIBI has limited value in differential diagnosis of neonatal cholestasis. (orig.)

  10. Hepatocellular carcinoma: clinical significance of signal heterogeneity in the hepatobiliary phase of gadoxetic acid-enhanced MR imaging

    Fujita, Nobuhiro; Nishie, Akihiro; Asayama, Yoshiki; Ushijima, Yasuhiro; Moirta, Koichiro; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Kubo, Yuichiro; Aishima, Shinichi [Kyushu University, Department of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan); Takayama, Yukihisa [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Shirabe, Ken [Kyushu University, Department of Surgery and Science, Graduate School of Medical Sciences, Fukuoka (Japan)

    2015-01-15

    To clarify the relationship between the biological behaviour of hepatocellular carcinomas (HCCs) and their signal intensity in the hepatobiliary phase of gadoxetic acid-enhanced MR imaging with a special focus on the signal heterogeneity. A total of 68 patients with 70 pathologically proven HCCs were enrolled. On the basis of the signal intensity in the hepatobiliary phase, the lesions were classified into three groups: group 1, homogeneous hypointensity (n = 44); group 2, heterogeneous hyperintensity (n = 20); and group 3, homogeneous hyperintensity (n = 6). The clinicopathological findings were compared among the three groups. The tumour size and the serum level of protein induced by vitamin K absence or antagonist-II (PIVKA-II) were significantly higher in group 2 compared to group 1 (p = 0.0155, p = 0.0215, respectively) and compared to group 3 (p = 0.0330, p = 0.0220, respectively). The organic anion transporting polypeptide 8 (OATP8) expression in group 2 and group 3 was significantly higher than in group 1 (p < 0.0001, p < 0.0001, respectively). Group 2 showed a significantly lower disease-free survival rate compared to group 1 (p = 0.0125), and group 2 was an independent prognostic factor for disease-free survival (p = 0.0308). HCCs in the hepatobiliary phase that are heterogeneously hyperintense on gadoxetic acid-enhanced MR imaging have more malignant potential than other types of HCCs. (orig.)

  11. Gadolinium-based contrast agents in pediatric magnetic resonance imaging

    Gale, Eric M.; Caravan, Peter [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, The Martinos Center for Biomedical Imaging, Boston, MA (United States); Rao, Anil G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); McDonald, Robert J. [College of Medicine, Mayo Clinic, Department of Radiology, Rochester, MN (United States); Winfeld, Matthew [University of Pennsylvania Perelman School of Medicine, Philadelphia, PA (United States); Fleck, Robert J. [Cincinnati Children' s Hospital Medical Center, Department of Pediatric Radiology, Cincinnati, OH (United States); Gee, Michael S. [MassGeneral Hospital for Children, Harvard Medical School, Division of Pediatric Imaging, Department of Radiology, Boston, MA (United States)

    2017-05-15

    Gadolinium-based contrast agents can increase the accuracy and expediency of an MRI examination. However the benefits of a contrast-enhanced scan must be carefully weighed against the well-documented risks associated with administration of exogenous contrast media. The purpose of this review is to discuss commercially available gadolinium-based contrast agents (GBCAs) in the context of pediatric radiology. We discuss the chemistry, regulatory status, safety and clinical applications, with particular emphasis on imaging of the blood vessels, heart, hepatobiliary tree and central nervous system. We also discuss non-GBCA MRI contrast agents that are less frequently used or not commercially available. (orig.)

  12. Part 1: MRI features of focal nodular hyperplasia with an emphasis on hepatobiliary contrast agents

    Sutherland, Tom; Seale, Melanie; Yap, Yap

    2014-01-01

    Focal nodular hyperplasia (FNH) is the second most common benign liver tumour and typically do not require any treatment. An accurate non-invasive diagnosis is therefore vital to avoid unnecessary intervention and to reassure patients. This article discusses the demographics and pathology of FNH and reviews the appearance of FNH at MRI using liver-specific contrast agents.

  13. Adrenal imaging agents

    Davis, M.A.; Hanson, R.N.; Holman, B.L.

    1980-01-01

    The goals of this proposal are the development of selenium-containing analogs of the aromatic amino acids as imaging agents for the pancreas and of the adrenal cortex enzyme inhibitors as imaging agents for adrenal pathology. The objects for this year include (a) the synthesis of methylseleno derivatives of phenylalanine and tryptophan, and (b) the preparation and evaluation of radiolabeled iodobenzoyl derivatives of the selenazole and thiazole analogs of metyrapone and SU-9055

  14. Gadolinium-ethoxybenzyl-DTPA as a hepatobiliary contrast agent for use in MR cholangiography: results of an in vivo phase-I clinical evaluation

    Bollow, M.; Taupitz, M.; Hamm, B.; Staks, T.; Wolf, K.J.; Weinmann, H.J.

    1997-01-01

    The purpose of this study was to investigate the time course of contrast enhancement in bile ducts and the gallbladder (GB) after injection of gadolinium-ethoxybenzyl-DTPA (Gd-EOB-DTPA). In a clinical phase-I study, MR imaging at 1.5T was performed in 16 healthy volunteers with four different doses of Gd-EOB-DTPA (10, 25, 50, and 100 μmol/kg b. w., four volunteers per dosage). The study protocol comprised a heavily T1-weighted fast multiplanar gradient-echo (GE) sequence before and at increasing intervals for up to 360 min after injection of Gd-EOB-DTPA. The signal enhancement was evaluated in extra-and intrahepatic bile ducts as well as in the GB. In all 16 volunteers the common bile duct showed intense signal enhancement beginning 5-16 min after injection (mean 10 min) and persisting for at least 120 min in 4 subjects and for 360 min in 12 subjects. The duration of signal enhancement was significantly (p < 0.05) longer for higher doses (50, 100 μmol/kg) than for lower doses (10, 25 μmol/kg). Intrahepatic bile ducts were hyperintense as compared with liver parenchyma in all subjects receiving 10 μmol/kg from approximately 50-120 min after contrast agent application. Intrahepatic bile ducts were not displayed using the higher doses, probably because of the strong enhancement of the liver parenchyma. Gallbladder contrasting was achieved in all cases beginning 7-33 min after injection (mean 19 min) and remained visible for up to 360 min in 94 %. Hyperintense visualization of normal extrahepatic bile ducts as well as the GB is regularly achieved with the hepatobiliary contrast agent Gd-EOB-DTPA. The dosage for hyperintense visualization of intrahepatic bile ducts is 10 μmol/kg. (orig.). With 8 figs., 2 tabs

  15. Hepatobiliary imaging: a comparison of 99Tcsup(m)-dihydro-thioctic acid and 99Tcsup(m)-pyridoxylidene glutamate in the non-jaundiced patient

    Jenner, R.E.; Howard, E.R.; Clarke, M.B.; Barrett, J.J.

    1978-01-01

    A comparison of two hepatobiliary imaging agents, 99 Tcsup(m)-dihydrothioctic acid ( 99 Tcsup(m)-DHT) and 99 Tcsup(m)-pyridoxylidene glutamate ( 99 Tcsup(m)-PG) has been carried out in 44 non-jaundiced patients. Thirty-one patients were admitted for investigation of upper abdominal pain and 13 patients were volunteers who were undergoing treatment for unrelated conditions. Satisfactory liver images were obtained with both agents in patients without liver disease, but they were inferior to those seen after 99 Tcsup(m)-sulphur colloid. 99 Tcsup(m)-PG produced clearer images of the gall-bladder and bile ducts than 99 Tcsup(m)-DHT. Non-visualization of the gall-bladder was interpreted as gall-bladder disease; in patients with inflammatory gall-bladder disease no gall-bladder image was seen (nine 99 Tcsup(m)-DHT, nine 99 Tcsup(m)-PG). The gall-bladder was also not demonstrated in two of the volunteers' group (one 99 Tcsup(m)-DHT, one 99 Tcsup(m)-PG), nor was a gall-bladder seen in five patients whose abdominal pain was not due to acute cholecystitis. Despite this, there was agreement between the results of imaging and oral cholecystography in 21 out of 22 subjects. 99 Tcsup(m)-PG is non-toxic, cheap and rapidly excreted by the liver into the bile. A 99 Tcsup(m)-PG scan would be useful when rapid diagnosis is required in suspected acute cholecystitis when conventional contrast radiology is unlikely to be of value. (author)

  16. Clinical evaluation of Tc-99m-mebrofenin and comparison with Tc-disofenin for radionuclide hepatobiliary imaging

    Klingensmith, W. III; Fritzberg, A.; Spitzer, V.

    1982-01-01

    The clinical comparison reported indicates that Tc-mebrofenin has a significantly lower level of renal excretion that Tc-disofenin at all bilirubin levels. At a total bilirubin level of 25 mg/dl the renal excretion of Tc-mebrofenin is still less than the renal excretion of Tc-disofenin in subjects with normal bilirubin levels. In addition, renal radioactivity in images was never seen in subjects with normal bilirubins while visualization of renal radioactivity is routine in normal subjects with Tc-disofenin. No significant differences were found in any other parameter including hepatocyte extraction efficiency, time of maximum hepatic radioactivity, and hepatic parenchymal washout. This study indicates that Tc-mebrofenin is equal to Tc-disofenin in its hepatobiliary characteristics and superior in its renal characteristics

  17. The role of Tc-99m IDA hepatobiliary and Tc-99m colloid hepatic imaging in primary biliary cirrhosis

    Aburano, T.; Yokoyama, K.; Shuke, N.; Kinuya, S.; Takayama, T.; Tonami, N.; Hisada, K.

    1991-01-01

    To assess the presence of primary biliary cirrhosis, 15 patients at various histopathologic stages were studied by Tc-99m IDA hepatobiliary and/or Tc-99m colloid hepatic imaging. In the earlier stages (I and II), seven of eight patients (88%) showed uniform hepatic retention of Tc-99m IDA. Of seven patients in the same stage, however, four (57%) showed no abnormality on Tc-99m colliod imaging. In three of these four negative patients (75%), uniform hepatic retention of Tc-99m IDA was noted. In the later stages (III and IV), all seven patients showed decreased clearance with or without delayed tracer appearance in the intestine and prominent hepatic retention on Tc-99m IDA imaging; with Tc-99m colloid imaging there was enlargement of the spleen and increased activity in the spleen and bone marrow. Thus, Tc-99m IDA imaging is considered to be more useful in revealing this functional disorder at the earlier stage of primary biliary cirrhosis and in evaluating progression from an earlier to a later stage of disease. Tc-99m colloid imaging also effectively evaluated progression

  18. Synthesis of 2,6-diisopropyl-phenylcarbamoylmethyl-iminodiacetic acid (DISIDA) and 4-n-p-butyl-phenylcarbamoylmethyl-iminodiacetic acid (BUTYL-IDA). Preparation of lyophilized kit to be used as 99(supm)Tc agent in hepatobiliary system

    Hamada, E.S.; Barbosa, M.F. de; Theodora, M.A.; Almeida, M. de; Colturato, M.T.; Muramoto, E.; Silva, C.P.G. da.

    1987-08-01

    The synthesis of 2,6 diisopropyl IDA (DISIDA) and 4-n-butyl IDA (BUTIL-IDA) is described. Their spectroscopic properties, radiopharmaceutical preparation and their use as 99 (sup m)Tc complex agent in hepatobiliary studies, are also reported. (Author) [pt

  19. Hepatobiliary scan in neonatal Jaundice

    Nahar, Nurun; Hasan, Mizanul; Karim, M.A.

    2002-01-01

    Jaundice is more or less common in newborn babies. Through physiological jaundice is most common cause of neonatal jaundice, possibility of obstructive jaundice especially biliary atresia should be kept in mind. Early diagnosis of biliary atresia followed by surgical treatment can save baby's life. Otherwise death is inevitable due to liver failure. Hepatobiliary scan is the imaging study of choice in neonatal jaundice especially when there is persistent conjugated hyperbilirubinaemia. Total 27 newborn babies of suspected biliary atresia, aged 14 days to 4 months were referred to Institute of Nuclear Medicine for Hepatobiliary scan. All of them had high serum bilirubin ranged from 6.0 mg/dl with an average of 9.35 ng/dl serum bilirubin level. Ultrasonography of hepatobiliary system was performed in 14 cases showing normal sized liver in 4 cases and hepatomegaly in 10 cases. Hepatobiliary scan was done with 99m Tc-Mebrofenin (Br IDA) after preparing the baby with phenobarbitone for 3-5 days. 20 (67%) cases were scan positive suggesting biliary atresia (BA) and 7(27%) cases were scan negative. In BA there will be increased hepatic uptake of the radionuclide without any significant excretion even in 24 hours delayed images. Presence of radiotracer in the bowel exclude the diagnosis of BA. Early diagnosis of biliary atresia is very important because in this condition surgery should be performed early (within 60 days of life). Studies suggest that hepatobiliary scan after hepatic stimulation with phenobarbitone for a period of 3-5 days is highly accurate for differentiating biliary atresia from other causes of neonatal jaundice. It is very important to perform hepatobiliary scan in a case of neonatal jaundice to exclude biliary atresia for the sake of baby's life.(author)

  20. Hepatobiliary magnetic resonance imaging in patients with liver disease: correlation of liver enhancement with biochemical liver function tests

    Kukuk, Guido M.; Schaefer, Stephanie G.; Hadizadeh, Dariusch R.; Schild, Hans H.; Willinek, Winfried A. [University of Bonn, Department of Radiology, Bonn (Germany); Fimmers, Rolf [University of Bonn, Department of Medical Biometry, Informatics and Epidemiology, Bonn (Germany); Ezziddin, Samer [Department of Nuclear Medicine, Bonn (Germany); Spengler, Ulrich [Department of Internal Medicine I, Bonn (Germany)

    2014-10-15

    To evaluate hepatobiliary magnetic resonance imaging (MRI) using Gd-EOB-DTPA in relation to various liver function tests in patients with liver disorders. Fifty-one patients with liver disease underwent Gd-EOB-DTPA-enhanced liver MRI. Based on region-of-interest (ROI) analysis, liver signal intensity was calculated using the spleen as reference tissue. Liver-spleen contrast ratio (LSCR) and relative liver enhancement (RLE) were calculated. Serum levels of total bilirubin, gamma glutamyl transpeptidase (GGT), aspartate aminotransferase (AST), alanine aminotransferase (ALT), glutamate dehydrogenase (GLDH), lactate dehydrogenase (LDH), serum albumin level (AL), prothrombin time (PT), creatinine (CR) as well as international normalised ratio (INR) and model for end-stage liver disease (MELD) score were tested for correlation with LSCR and RLE. Pre-contrast LSCR values correlated with total bilirubin (r = -0.39; p = 0.005), GGT (r = -0.37; p = 0.009), AST (r = -0.38; p = 0.013), ALT (r = -0.29; p = 0.046), PT (r = 0.52; p < 0.001), GLDH (r = -0.55; p = 0.044), INR (r = -0.42; p = 0.003), and MELD Score (r = -0.53; p < 0.001). After administration of Gd-EOB-DTPA bilirubin (r = -0.45; p = 0.001), GGT (r = -0.40; p = 0.004), PT (r = 0.54; p < 0.001), AST (r = -0.46; p = 0.002), ALT (r = -0.31; p = 0.030), INR (r = -0.45; p = 0.001) and MELD Score (r = -0.56; p < 0.001) significantly correlated with LSCR. RLE correlated with bilirubin (r = -0.40; p = 0.004), AST (r = -0.38; p = 0.013), PT (r = 0.42; p = 0.003), GGT (r = -0.33; p = 0.020), INR (r = -0.36; p = 0.011) and MELD Score (r = -0.43; p = 0.003). Liver-spleen contrast ratio and relative liver enhancement using Gd-EOB-DTPA correlate with a number of routinely used biochemical liver function tests, suggesting that hepatobiliary MRI may serve as a valuable biomarker for liver function. The strongest correlation with liver enhancement was found for the MELD Score. (orig.)

  1. Hepatobiliary ultrasonography

    Sembiring, J.

    2018-03-01

    Ultrasound is one of the most widely used imaging technologies in medicine. It is portable, free of radiation risk, non-invasive and relatively inexpensive when compared with other imaging modalities, such as magnetic resonance and computed tomography. Ultrasound is a useful procedure for evaluating many structures organ in our body. An examination may include the entirety of the abdomen and retroperitoneum from a single organ to several organs. An abdominal ultrasound examination survey would include the liver, gallbladder, biliary tree, pancreas, spleen, kidneys and retroperitoneal structures. It needsperforming when there is a valid medical reason.

  2. Hepatobiliary transit times of gadoxetate disodium (Primovist) for protocol optimization of comprehensive MR imaging of the biliary system-What is normal?

    Ringe, Kristina I., E-mail: ringe.kristina@mh-hannover.de [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC 27710 (United States); Hannover Medical School, Department of Radiology, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Husarik, Daniela B., E-mail: danielahusarik@yahoo.com [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC 27710 (United States); Gupta, Rajan T., E-mail: rajan.gupta@duke.edu [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC 27710 (United States); Boll, Daniel T., E-mail: daniel.boll@duke.edu [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC 27710 (United States); Merkle, Elmar M., E-mail: elmar.merkle@duke.edu [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC 27710 (United States)

    2011-08-15

    Objective: The purpose of this study was to determine transit times for excretion of Gd-EOB-DTPA into different segments of the hepatobiliary system in patients with normal liver function. Methods: This retrospective study was IRB approved with a waiver of consent granted. 61 patients (39 female, 22 male, mean age 52.5 years) with normal liver and renal function who underwent contrast enhanced hepatic MRI after injection of 10 mLGd-EOB-DTPA at 1.5 T and 3 T were included. Two readers evaluated all delayed images (3-20 min post contrast) for the presence of contrast agent in the intrahepatic bile ducts (IBD), the common bile duct (CBD), the gallbladder and the duodenum. A two-tailed, unpaired Student's t-test with p < 0.05 deemed significant was used to determine whether transit times were affected by patient gender, age or body mass index. Results: 20 min after contrast initiation, Gd-EOB-DTPA could be detected in the IBD and the CBD in all patients (100%); gallbladder reflux was visible in 53 (86.9%), duodenal excretion in 40 patients (65.5%), respectively. Mean transit times for contrast appearance in the various segments were as follows: IBD 12 min 13 s; CBD 12 min 27 s; gallbladder 13 min 32 s. Transit times were not significantly affected by patient gender, age or BMI. Conclusion: Within 20 min post contrast initiation, Gd-EOB-DTPA can be expected in the IBD and the CBD in patients with normal liver function. However, functional information about the sphincter Oddi complex can be ascertained only in about two thirds of these patients within this timeframe.

  3. Design and Optimization of Gadolinium Based Contrast Agents for Magnetic Resonance Imaging

    Pereira, G.A.; Geraldes, C.F.G.C.; University of Coimbra

    2007-01-01

    The role of Gd 3+ chelates as contrast agents in Magnetic Resonance Imaging is discussed. The theory describing the different contributions to paramagnetic relaxation relevant to the understanding of the molecular parameters determining the relativity of those Gd 3+ chelates, is presented. The experimental techniques used to obtain those parameters are also described. Then, the various approaches taken to optimize those parameters, leading to maximum relativity (efficiency) of the contrast agents, are also illustrated with relevant examples taken from the literature. The various types of Gd 3+ -based agents, besides non-specific and hepatobiliary agents, are also discussed, namely blood pool, targeting, responsive and paramagnetic chemical shift saturation transfer (PARACEST) agents. Finally, a perspective is presented of some of the challenges lying ahead in the optimization of MRI contrast agents to be useful in Molecular Imaging. (author)

  4. Technetium-99m-labeled N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetic acid (/sup 99m/Tc HIDA): a new radiopharmaceutical for hepatobiliary imaging studies

    Ryan, J.; Cooper, M.; Loberg, M.; Harvey, E.; Sikorski, S.

    1977-01-01

    An easily formulated, stable kit preparation of technetium-99m HIDA, suitable for use in humans, was developed and tested in mice and dogs. The tracer was cleared rapidly from the blood and excreted predominantly by the liver in both species. In dogs, the hepatobiliary clearance of Tc-99m HIDA was significantly greater than that of C-14 HIDA and Sn-113 HIDA. The LD 50 for HIDA in mice, 168 mg/kg, exceeded the average human dose by a factor of 1000 on a per-weight basis. Blood clearance curves for Tc-99m HIDA in 12 normal subjects were biexponential with half-times of 4.6 +- 1.0 min and 31.5 +- 7.0 min, and cumulative 90-min urine samples contained 14.2 +- 1.8% of the injected dose. Images in normal subjects and nonjaundiced patients showed rapid concentration of tracer by the liver and activity was present within the biliary system in 10 to 20 min. In jaundiced patients, the tracer blood clearance was delayed and urinary excretion increased, but intestinal activity, indicating biliary patency, was imaged in those patients without complete focal obstruction of the common duct. Technetium-99m HIDA is a nontoxic radiopharmaceutical useful for clinical evaluation of hepatobiliary disorders in humans

  5. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    Hope, Thomas A.; Verdin, Emily F.; Bergsland, Emily K.; Ohliger, Michael A.; Corvera, Carlos University; Nakakura, Eric K.

    2015-01-01

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV max , SUV peak , SUV mean , and Vol isocontour . Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV max 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV max 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  6. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    Hope, Thomas A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco VA Medical Center, San Francisco, CA (United States); Verdin, Emily F. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Bergsland, Emily K. [Division of Hematology/Oncology, Department of Medicine, University of California, San Francisco, San Francisco, CA (United States); Ohliger, Michael A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco General Hospital, San Francisco, CA (United States); Corvera, Carlos University; Nakakura, Eric K. [Division of Surgical Oncology, Department of Surgery, University of California, San Francisco, San Francisco, CA (United States)

    2015-09-18

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV{sub max}, SUV{sub peak}, SUV{sub mean}, and Vol{sub isocontour}. Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV{sub max} 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV{sub max} 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  7. Tc-99m imaging agents

    Weininger, J.; Trumper, J.

    1984-01-01

    A wide range of pharmaceuticals for labeling with Tc-99m, developed by the Soreq Radiopharmaceuticals Department, is described. Details of the production and quality control of 13 kits are given, as well as the range of results required for consistently high quality imaging agents

  8. Pharmacokinetic and imaging studies of the hepatobiliary agent sup(99m)Tc-pyridoxal leucine

    Sawas-Dimopoulou, C.; Chiotellis, E.; Dassiou, A.; Papanicolaou, N.; Simitzis, G.; Koutoulidis, K.; Hadzilouka-Mantaka, A.

    1978-01-01

    An investigation into the usefulness of sup(99m)Tc-pyridoxal leucine has demonstrated its advantages over 131 I-rose bengal in the diagnosis of patients with several liver and gall bladder complaints. Toxicity studies in mice, rabbits and dogs showed no histological signs of tissular lesions at doses of up to 5000 to 25,000 times the clinical dose. Visualization of the liver, gall bladder and biliary excretion into intestines was rapid. The appearance of activity into the intestines was delayed in patients with partial obstruction of the common bile duct. Insufficient diagnostic information was provided in jaundiced patients with higher levels of bilirubin (7 to 12 mg%). These patients showed reduced liver uptake with high background, and intestinal activity was not always clearly visualized in an 18 h study. At bilirubin levels higher than 12 mg% no liver uptake was usually observed, but only renal activity. 131 I-rose bengal was preferable for the differential diagnosis of obstructive jaundice in these patients. (U.K.)

  9. Emergency surgeon-performed hepatobiliary ultrasonography.

    Kell, M R

    2012-02-03

    BACKGROUND: Acute hepatobiliary pathology is a common general surgical emergency referral. Diagnosis requires imaging of the biliary tree by ultrasonography. The accuracy and impact of surgeon-performed ultrasonography (SUS) on the diagnosis of emergent hepatobiliary pathology was examined. METHODS: A prospective study, over a 6-month period, enrolled all patients with symptoms or signs of acute hepatobiliary pathology. Patients provided informed consent and underwent both SUS and standard radiology-performed ultrasonography (RUS). SUS was performed using a 2-5-MHz broadband portable ultrasound probe by two surgeons trained in ultrasonography, and RUS using a 2-5-MHz fixed unit. SUS results were correlated with those of RUS and pathological diagnoses. RESULTS: Fifty-three consecutive patients underwent 106 ultrasonographic investigations. SUS agreed with RUS in 50 (94.3 per cent) of 53 patients. SUS accurately detected cholelithiasis in all but two cases and no patient was inaccurately diagnosed as having cholelithiasis at SUS (95.2 per cent sensitivity and 100 per cent specificity). As an overall complementary diagnostic tool SUS provided the correct diagnosis in 96.2 per cent of patients. Time to scan was significantly shorter following SUS (3.1 versus 12.0 h, P < 0.05). CONCLUSION: SUS provides a rapid and accurate diagnosis of emergency hepatobiliary pathology and may contribute to the emergency management of hepatobiliary disease.

  10. Hepatobiliary Hands of Hopkins.

    Pitt, Henry A

    2018-02-01

    This historical perspective documents the role that John L. Cameron played in advancing hepatobiliary research, education, and surgery at Johns Hopkins in the 1970s, 1980s, and 1990s. Dating back to William S. Halsted in the 19th century, leaders of the Department of Surgery at Johns Hopkins have been interested in hepatobiliary disease and surgery. John L. Cameron had broad hepato-pancreato-biliary (HPB) interests when he completed his surgical training. Over the next 3 decades, he focused on the pancreas. As a result, many faculty and trainee hepatobiliary careers were launched. This perspective is based on 18 years of service as a surgical resident and faculty member at Johns Hopkins. An extensive literature search on the hepatobiliary publications of Halsted, Trimble, Blalock, Longmire, Zuidema, and Cameron was undertaken for this manuscript. Numerous hepatobiliary publications from Johns Hopkins from the 1970s, 1980s, 1990s, and early 2000s were also reviewed. John L. Cameron's early biliary interests included stones, infections, malignancies, and strictures. He was innovative with respect to portal hypertension and Budd-Chiari surgery and supportive when liver transplantation emerged in the 1980s. Volume-outcome studies in the 1990s included hepatic and complex biliary surgery. He supported and encouraged studies of biliary lithotripsy, laparoscopic cholecystectomy, clinical pathways, hepatobiliary cysts, and gallstone pathogenesis. Lessons learned by many who worked with John L. Cameron included the importance of mentorship, innovation, friendship, and collaboration. He taught leadership and change management by example. He fostered a multidisciplinary approach and encouraged randomized controlled trials.

  11. Prostate Activated Prodrugs and Imaging Agents

    Jones, Graham B

    2004-01-01

    .... The substrate chosen was a 3 component system composed of a peptide sequence with affinity for PSA, an imaging agent and a deactivating bridge-linker, which electronically incapacitates the imaging agent...

  12. Hepatobiliary phase images using gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid-enhanced MRI as an imaging surrogate for the albumin–bilirubin grading system

    Takatsu, Yasuo, E-mail: pcblue2@yahoo.co.jp [Department of Radiology, Osaka Red Cross Hospital, 5-30 Fudegasaki, Tennouji-ku, Osaka, 543-8555 (Japan); Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942 (Japan); Kobayashi, Satoshi, E-mail: satoshik@staff.kanazawa-u.ac.jp [Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942 (Japan); Miyati, Tosiaki, E-mail: ramiyati@mhs.mp.kanazawa-u.ac.jp [Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942 (Japan); Shiozaki, Toshiki, E-mail: shiozaki.toshiki@gmail.com [Department of Radiology, Osaka Red Cross Hospital, 5-30 Fudegasaki, Tennouji-ku, Osaka, 543-8555 (Japan)

    2016-12-15

    Objectives: To clarify the correlation between hepatobiliary phase (HBP) images using gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid (Gd-EOB-DTPA) and albumin–bilirubin (ALBI) grading system. Materials and methods: We evaluated 220 consecutive patients who underwent liver magnetic resonance imaging with Gd-EOB-DTPA. Quantitative liver–spleen contrast ratio (Q-LSC) was calculated in HBP images approximately 20 min after Gd-EOB-DTPA administration. To evaluate the degree of association between Q-LSC and ALBI grade, the Child–Pugh (C-P) score was used for comparison. Correlation coefficients were calculated, and median Q-LSC values were compared with the C-P scores and ALBI grades. The Steel–Dwass multiple comparison test was used for statistical analysis. Results: The correlation coefficient between Q-LSC and C-P score was −0.35, P < 0.0001, and the ALBI grade was −0.61, P < 0.0001. Q-LSC of overall median, C-P A, B, and C were 1.94, 1.91, 1.96, and 1.33, respectively. The differences between C-P A and C-P B, C-P B and C-P C, and C-P A and C-P C were P = 0.999, 0.126, and 0.149, respectively. Q-LSC of the overall median, ALBI grade 1, 2, and 3 were 1.94, 2.12, 1.69, and 1.30, respectively. The differences between ALBI grades 1 and 2, 2 and 3, and 1 and 3 were P < 0.0001, P = 0.0466, and P = 0.0035, respectively. Q-LSC was better correlated and discriminated by ALBI grade than C-P score. Conclusion: A strong correlation was observed between Q-LSC of an HBP image with Gd-EOB-DTPA and ALBI grade; HBP imaging could be a surrogate for the ALBI grade.

  13. Pathophysiological analysis of hepatobiliary function on sup(99m)Tc-labeled-cholescintigram

    Oyama, K; Hayashi, S; Kogure, T; Hirakawa, K; Akaike, A [Tokyo Univ. (Japan). Faculty of Medicine

    1979-05-01

    sup(99m)Tc-pylidoxylideneisoleucine (PI) was injected into 106 patients in order to study the mechanism of bile accumulation in the gallbladder in analysis of the visualization time of the gallbladder, intrahepatic bile duct, common bile duct and duodenum on sup(99m)Tc-PI cholescintigrams relating to hepatobiliary function. In cases of normal hepatobiliary function, sup(99m)Tc-PI is rapidly cleared from the blood by hepatocytes and is rapidly excreted through the biliary tree into the duodenum. The common bile duct was seen within 15 min of injection in 93.5% of the patients, the gallbladder within 20 min in 80.8%, the intrahepatic bile duct within 20 min in 96.3%, and the duodenum within 30 min in 58%. Marked accumulation of sup(99m)Tc-PI was noted in the gallbladder within 30 min. In cases of hepatobiliary dysfunction, the duodenum is visualized earlier than the gallbladder and intrahepatic bile duct, and the visualization ratio of the gallbladder and intrahepatic bile duct is decreased with an increased degree of hepatobiliary dysfunction. In regard to serum bilirubin level, the gallbladder was seen up to 3.5 mg%, the intrahepatic bile duct up to 4.0 mg% and the common bile duct up to 22.6 mg%. The duodenum was seen in all but two cases of complete obstruction of the common bile duct. In regard to meal time, marked accumulation of sup(99m)Tc-PI in the gallbladder was seen within 30 min and re-dilatation was seen with in 90 min after the beginning of contraction. In cases of normal hepatobiliary function, the gallbladder was seen in over 70% of the cases more than two hours after meals. This study shows that the hepatobiliary tract can be easily imaged by sup(99m)Tc-PI in proportion to hepatobiliary function and that this agent may be useful in the diagnosis of abnormal hepatobiliary tract and the jaundiced patient with hyperbilirubinemias. (Bell, E.).

  14. Prognosis of small hepatocellular nodules detected only at the hepatobiliary phase of Gd-EOB-DTPA-enhanced MR imaging as hypointensity in cirrhosis or chronic hepatitis

    Higaki, Atsushi; Ito, Katsuyoshi; Tamada, Tsutomu; Sone, Teruki; Kanki, Akihiko; Noda, Yasufumi; Yasokawa, Kazuya; Yamamoto, Akira [Kawasaki Medical School, Department of Radiology, Kurashiki City, Okayama (Japan)

    2014-10-15

    To evaluate the prognosis of ''strict'' high-risk nodules (small hepatocellular nodules detected only in the hepatobiliary phase of initial Gd-EOB-DTPA-enhanced MR examination) in patients with cirrhosis or chronic hepatitis. The study included thirty-three patients with 60 ''strict'' high-risk nodules showing hypointensity at the hepatobiliary phase that was undetectable at the vascular phase and other conventional sequences of initial Gd-EOB-DTPA-enhanced MR imaging. These nodules were observed on follow-up MR examinations until hypervascularity was detected. The potential predictive factors for hypervascular transformation were compared between two groups (group A showing hypervascular transformation, group B not showing hypervascularization). Ten (16.7 %) of 60 ''strict'' high-risk nodules showed hypervascular transformation during follow-up periods (group A). The growth rates of the nodules in group A (6.3 ± 4.5 mm/year) were significantly higher than those in group B (3.4 ± 7.2 mm/year) (p = 0.003). Additionally, the median observation period in group A (177.5 ± 189.5 day) was significantly shorter than in group B (419 ± 372.2 day) (p = 0.045). The other predictive factors were not significantly correlated with hypervascularization. Subsets of ''strict'' high-risk nodules showed hypervascular transformation during follow-up periods in association with increased growth rates, indicating that nodule growth rate is an important predictive factor for hypervascularization. (orig.)

  15. Obstructive jaundice due to hepatobiliary cystadenoma or cystadenocarcinoma

    Erdogan, Deha; Busch, Olivier R. C.; Rauws, Erik A. J.; van Delden, Otto M.; Gouma, Dirk J.; van-Gulik, Thomas M.

    2006-01-01

    Hepatobiliary cystadenomas (HBC) and cystadenocarcinomas are rare cystic lesions. Most patients with these lesions are asymptomatic, but presentation with obstructive jaundice may occur. The first patient presented with intermittent colicky pain and recurrent obstructive jaundice. Imaging studies

  16. Tc99m- hepatobiliary iminodiacetic acid (HIDA) scintigraphy in clinical practice

    Lambie, H.; Cook, A.M.; Scarsbrook, A.F.; Lodge, J.P.A.; Robinson, P.J.; Chowdhury, F.U.

    2011-01-01

    There have been evolutionary changes in the management of pathological conditions of the hepatobiliary system over recent years, particularly with an increasing emphasis on modern hepatobiliary surgical techniques. Concurrent advances have occurred in imaging technology and availability, leading to a greater use of ultrasound, multidetector computed tomography (CT), and magnetic resonance imaging (MRI) in the primary evaluation of hepatobiliary disease. Radionuclide imaging using technetium 99m (Tc 99m ) hepatobiliary iminodiacetic acid (HIDA) derivatives is an established technique that complements morphological imaging, providing valuable functional information in both pre- and postoperative evaluation of patients with suspected or known hepatobiliary disease. This review discusses the current clinical indications for Tc 99m HIDA scintigraphy using clinical cases to demonstrate how this technique continues to play a valuable diagnostic role in the assessment of the functional integrity of the hepatobiliary system.

  17. Hepatobiliary delivery of polyaminopolycarboxylate chelates: Synthesis and characterization of a cholic acid conjugate of EDTA and biodistribution and imaging studies with its indium-111 chelate

    Betebenner, D.A.; Carney, P.L.; Zimmer, A.M.; Kazikiewicz, J.M.; Bruecher, E.S.; Sherry, A.D.; Johnson, D.K. (Abbott Laboratories, Abbott Park, Illinois (USA))

    1991-03-01

    A conjugate in which the steroid nucleus of cholic acid was linked to EDTA via an 11-atom spacer was obtained by reacting the succinimidyl ester of cholic acid with the amine formed by reaction of a benzyl isothiocyanate derivative of EDTA with N-(tert-butoxycarbonyl)ethylenediamine and subsequent deprotection. Potentiometric titration studies with model complexes showed that the EDTA moiety retained the ability to form 1:1 chelates of high thermodynamic stability, although formation constants were some 3-4 log K units lower for complexes of the conjugate than for the analogous chelates with underivatized EDTA. A complex formed between the cholic acid-EDTA conjugate and 111InIII was clearly rapidly into the liver when injected iv into mice, with subsequent excretion from the liver into the gastrointestinal tract being complete within 1 h of injection. Radioscintigraphic imaging studies conducted in a rabbit given the 111In-labeled conjugate also showed early liver uptake followed by rapid clearance from the liver into the intestine, with good visualization of the gallbladder in images obtained at 20-25 min postinjection. It is concluded that conjugation to cholic acid provides a useful means for the hepatobiliary delivery of EDTA chelates that otherwise exhibit predominantly extracellular distribution and renal clearance.

  18. Hepatobiliary delivery of polyaminopolycarboxylate chelates: Synthesis and characterization of a cholic acid conjugate of EDTA and biodistribution and imaging studies with its indium-111 chelate

    Betebenner, D.A.; Carney, P.L.; Zimmer, A.M.; Kazikiewicz, J.M.; Bruecher, E.S.; Sherry, A.D.; Johnson, D.K.

    1991-01-01

    A conjugate in which the steroid nucleus of cholic acid was linked to EDTA via an 11-atom spacer was obtained by reacting the succinimidyl ester of cholic acid with the amine formed by reaction of a benzyl isothiocyanate derivative of EDTA with N-(tert-butoxycarbonyl)ethylenediamine and subsequent deprotection. Potentiometric titration studies with model complexes showed that the EDTA moiety retained the ability to form 1:1 chelates of high thermodynamic stability, although formation constants were some 3-4 log K units lower for complexes of the conjugate than for the analogous chelates with underivatized EDTA. A complex formed between the cholic acid-EDTA conjugate and 111InIII was clearly rapidly into the liver when injected iv into mice, with subsequent excretion from the liver into the gastrointestinal tract being complete within 1 h of injection. Radioscintigraphic imaging studies conducted in a rabbit given the 111In-labeled conjugate also showed early liver uptake followed by rapid clearance from the liver into the intestine, with good visualization of the gallbladder in images obtained at 20-25 min postinjection. It is concluded that conjugation to cholic acid provides a useful means for the hepatobiliary delivery of EDTA chelates that otherwise exhibit predominantly extracellular distribution and renal clearance

  19. Enhancing contrast of magnetic resonance imaging in patients with ...

    DTPA), a recent magnetic resonance imaging (MRI) contrast agent, in hepatobiliary system of patients with liver cirrhosis. Methods: Liver cirrhosis patients that underwent contrast MRI examination at Renai Hospital, Taipei City, Taiwan were ...

  20. Hepatobiliary scanning using /sup 99m/Tc--pyridoxylideneglutamate

    Matolo, N.M.; Stadalnik, R.C.; Wolfman, E.F. Jr.

    1977-01-01

    Technetium 99m-pyridoxylideneglutamate (99mTc-PG) administered intravenously is excreted by hepatocytes into the bile canaliculi and enters the gallbladder through the cystic duct and consequently, can be used for scanning the hepatobiliary ductal system. A total of 166 patients representing 27 normal subjects, 84 patients referred for investigation for pain in the upper right quadrant of the abdomen and 55 jaundiced patients were evaluated with 99mTc-PG. In normal human volunteers, the agent reached the liver in five minutes, and the common bile duct, gallbladder, and duodenum within 15 minutes. Satisfactory images of the hepatobiliary tract were obtained using small dosages of 99mTc-PG. The gallbladder was not visualized when the cystic duct was occluded. In the presence of acute cholecystitis, cystic duct obstruction, or in chronic cholecystitis where other roentgenographic studies showed a nonfunctioning gallbladder, there was no concentration of 99mTc-PG in the gallbladder. In partial common bile duct obstruction, distended common bile duct was visualized along with delay in transit of radioactivity into the duodenum. Complete common bile duct obstruction was associated with no radioactivity in either the biliary or the gastrointestinal tracts up to 24 hours after injection. Hepatocellular disease was characterized by delayed liver clearance and delayed visualization of biliary and gastrointestinal tracts. 99mTc-PG scanning proved capable of differentiating betweenhepatocellular disease and extrahepatic biliary tract obstruction

  1. Imaging-based evaluation of liver function: comparison of {sup 99m}Tc-mebrofenin hepatobiliary scintigraphy and Gd-EOB-DTPA-enhanced MRI

    Geisel, Dominik; Gebauer, Bernhard [Charite Campus Virchow-Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Luedemann, Lutz [Essen University Hospital, Department of Medical Physics, Essen (Germany); Froeling, Vera; Denecke, Timm [Charite Campus Virchow-Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Charite Campus Virchow-Klinikum, Department of Nuclear Medicine, Berlin (Germany); Malinowski, Maciej; Stockmann, Martin; Baron, Annekathrin; Seehofer, Daniel [Charite Campus Virchow-Klinikum, Department of General, Visceral and Thoracic Surgery, Berlin (Germany); Prasad, Vikas [Charite Campus Virchow-Klinikum, Department of Nuclear Medicine, Berlin (Germany)

    2015-05-01

    To compare Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin hepatobiliary scintigraphy (HBS) as imaging-based liver function tests for separate evaluation of right (RLL) and left liver lobe (LLL) function. Fourteen patients underwent Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin HBS after portal vein embolization within 24 h. Relative enhancement (RE) and hepatic uptake index (HUI) were determined from MRI; and T{sub max}, T{sub 1/2} and mebrofenin uptake were determined from HBS, all values separately for RLL and LLL. Mebrofenin uptake correlated significantly with HUI and RE for both liver lobes. There was strong correlation of mebrofenin uptake with HUI for RLL (r{sup 2} = 0.802, p = 0.001) and RE for LLL (r{sup 2} = 0.704, p = 0.005) and moderate correlation with HUI for LLL (r{sup 2} = 0.560, p = 0.037) and RE for RLL (r{sup 2} = 0.620, p = 0.018). Correlating the percentage share of RLL function derived from MRI (with HUI) with the percentage of RLL function derived from mebrofenin uptake revealed a strong correlation (r{sup 2} = 0.775, p = 0.002). Both RE and HUI correlate with mebrofenin uptake in HBS. The results suggest that Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin HBS may equally be used to separately determine right and left liver lobe function. (orig.)

  2. Gastrointestinal and hepatobiliary radiology

    Graham, R.N.J.; Perriss, R.W.; Scarsbrook, A.F.

    2006-01-01

    This is the fifth in the series of short reviews of internet-based radiological learning resources and will focus on gastrointestinal (GI) and hepatobiliary radiology. Below are details of a few of the higher quality resources currently available. Most of the sites cater for medical students and trainee or non-specialist radiologists, but may be also be of interest to specialists, especially for use in teaching. Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (May 2006)

  3. Hepatobiliary sequential scintiscanning

    Germann, G.; Hottenrott, C.; Maul, F.D.

    1985-01-04

    The duodeno-gastric reflux was evaluated in 33 patients following gastric surgery by functional hepato-biliary scintigraphy. In 16 of 26 patients with gastric resection a reflux was found. The Y-en-Roux and the retrocolic B II resection with Braun's Anastomosis showed the lowest incidence of reflux. The functional scintigraphy permits an objective diagnosis of reflux without provocation by diagnostic manipulations. The high percentage of accuracy in evaluating reflux recommends the scintigraphy as an optimal method in postoperative reflux control.

  4. New series of Tc-99m-labeled hepatobiliary tracers: N'-acyl- and N'-sulfonyl ethylenediamine-N,N-diacetic acids

    Karube, Y.; Kono, A.; Maeda, T.; Ohya, M.; Matsushima, Y.

    1981-01-01

    Various Tc-99m-labeled N'-substituted derivatives of ethylenediamine-N,N-diacetic acid (EDDA) are evaluated as hepatobiliary imaging agents. N-substituted aromatic acyl and aromatic sulfonyl derivatives of EDDA, labeled with Tc-99m, were administered to rabbits and golden hamsters, and the distribution indicated clearance by the hepatobiliary system. N'-aromatic sulfonyl EDDAs were labeled with Tc-99m by the SnCl 2 method with more than 99% yield. Clearance of Tc-99m-p-toluenesulfonyl EDDA from the blood and the liver was as rapid as that of TC-99m N-(2,6-diethylphenylcarbamoylmethyl)iminodiacetic acid (Tc-99m benzenesulfonyl EDDA lowered urinary excretion. It is concluded that the sulfonyl EDDAs provide a fruitful source for Tc-99m-labeled hepatobiliary radiopharmaceuticals

  5. New series of Tc-99m-labeled hepatobiliary tracers: N'-acyl- and N'-sulfonyl ethylenediamine-N,N-diacetic acids

    Karube, Y.; Kono, A.; Maeda, T.; Ohya, M.; Matsushima, Y.

    1981-01-01

    Various Tc-99m-labeled N'-substituted derivatives of ethylenediamine-N,N-diacetic acid (EDDA) are evaluated as hepatobiliary imaging agents. N'-substituted aromatic acyl and aromatic sulfonyl derivatives of EDDA, labeled with Tc-99m, were administered to rabbits and golden hamsters, and the distribution indicated clearance by the hepatobiliary system. N'-aromatic sulfonyl EDDAs were labeled with Tc-99m by the SnCl 2 method with more than 99% yield. Clearance of Tc-99m-p-toluenesulfonyl EDDA from the blood and the liver was as rapid as that of Tc-99m N-(2,6-diethylphenylcarbamoylmethyl)iminodiacetic acid (Tc-99m diethyl IDA). Substitution of a bulky group at the aromatic ring in Tc-99m benzene-sulfonyl EDDA lowered urinary excretion. It is concluded that the sulfonyl EDDAs provide a fruitful source for Tc-99m-labeled hepatobiliary radiopharmaceuticals

  6. Stable agents for imaging investigations

    Tofe, A.J.

    1976-01-01

    This invention concerns highly stable compounds useful in preparing technetium 99m based scintiscanning exploration agents. The compounds of this invention include a pertechnetate reducing agent or a solution of oxidized pertechnetate and an efficient proportion, sufficient to stabilize the compounds in the presence of oxygen and of radiolysis products, of ascorbic acid or a pharmaceutically acceptable salt or ester of this acid. The invention also concerns a perfected process for preparing a technetium based exploration agent, consisting in codissolving the ascorbic acid or a pharmaceutically acceptable salt or ester of such an acid and a pertechnetate reducing agent in a solution of oxidized pertechnetate [fr

  7. Contrast Agent in Magnetic Resonance Imaging

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...

  8. Tc-99m labeled Sparfloxacin: A specific infection imaging agent

    Singh, A.K.; Verma, J.; Bhatnagar, A.; Ali, A.

    2003-01-01

    Radiolabeled antibiotics are being used for the specific diagnosis of infection by exploiting their specific binding properties to the bacterial component, thereby making it possible to differentiate infection from sterile lesions. A new radiopharmaceutical, Tc-99m Sparfloxacin has been developed for infection imaging. Sparfloxacin is a quinolone based broad-spectrum antibiotic, which is more potent than Ciprofloxacin. Radiolabeling of Sparfloxacin with Tc-99m was standardized using direct labeling protocol. Labeling efficiency, in-vitro and in-vivo stability, blood kinetics and organ distribution studies (in balb/c mice and New Zealand White Rabbits at different time interval up to 24hrs) were carried out. Biological activity of Sparfloxacin after its labeling with Tc-99m was evaluated with S.aureus using Peptone water (DIFCO) as media. Turpentine oil (100 μl) in left thigh and S.aureus (100μl of 3x10 7 cells) in right thigh were injected intramuscularly to create sterile and infective inflammation respectively in six New Zealand white rabbits. The localization kinetics of the radiolabeled complex were studied in the animal model by injecting 70-75MBq of Tc-99m Sparfloxacin intravenously in the ear of rabbit and the images were taken with a Gamma-camera (ECIL) at different post-injection time intervals. Standardized protocol produced >95% labeled complex. About 8% of tracer leached out at 24 hrs when incubated in serum at 37 0 C, confirming high stability of the complex. Blood clearance in rabbit revealed biphasic pattern and 50% of the complex clears from the blood within 5 min. Biodistribution studies in balb/c mice showed hepatobiliary route of excretion. Presence of insignificant amount of tracer at 24 hrs in the stomach confirmed high in vivo stability of the complex. Imaging in rabbits showed significant concentration of tracer in lesions with infection. Typical imaging patterns revealed initial accumulation of radiotracer in both sterile inflammatory

  9. Effect of complete biliary-tract obstruction on serial hepatobiliary imaging in an experimental model: concise communication

    Klingensmith, W.C.; Whitney, W.P.; Spitzer, V.M.; Klintmalm, G.B.; Koep, L.M.; Kuni, C.C.

    1981-01-01

    In order to determine the effect of biliary obstruction on hepatocyte clearance and bile flow, five dogs were imaged before, and three times a week after, surgical ligation of the common bile duct. THe first postoperative study was performed 3 hr after surgery. Bile flow and duct function were evaluated from analog images; hepatocyte clearance (HC) was estimated in digital images from the ratio of liver to cardiac blood-pool counts at 3 min. Liver function tests were measured serially. 3 hr after surgery the HC index and liver function tests were still normal. Analog images showed no intestinal radioactivity, but accumulation was seen in the distending biliary tract. on the third postoperative day, all liver function tests were abnormal and the HC index was significantly decreased (p less than 0.01). The biliary tract was never seen beyond the first postoperative day. Thus, complete obstruction of the common bile duct does not stop bile flow or cause significant hepatocyte damage in the first few hours. By the third day of obstruction, however, no bile flow is detectible and significant hepatocyte damage has occurred

  10. Effect of complete biliary-tract obstruction on serial hepatobiliary imaging in an experimental model: concise communication. [Dogs

    Klingensmith, W.C.; Whitney, W.P.; Spitzer, V.M.; Klintmalm, G.B.; Koep, L.M.; Kuni, C.C.

    1981-01-01

    In order to determine the effect of biliary obstruction on hepatocyte clearance and bile flow, five dogs were imaged before, and three times a week after, surgical ligation of the common bile duct. THe first postoperative study was performed 3 hr after surgery. Bile flow and duct function were evaluated from analog images; hepatocyte clearance (HC) was estimated in digital images from the ratio of liver to cardiac blood-pool counts at 3 min. Liver function tests were measured serially. 3 hr after surgery the HC index and liver function tests were still normal. Analog images showed no intestinal radioactivity, but accumulation was seen in the distending biliary tract. on the third postoperative day, all liver function tests were abnormal and the HC index was significantly decreased (p less than 0.01). The biliary tract was never seen beyond the first postoperative day. Thus, complete obstruction of the common bile duct does not stop bile flow or cause significant hepatocyte damage in the first few hours. By the third day of obstruction, however, no bile flow is detectible and significant hepatocyte damage has occurred.

  11. Multimodal nanoparticle imaging agents: design and applications

    Burke, Benjamin P.; Cawthorne, Christopher; Archibald, Stephen J.

    2017-10-01

    Molecular imaging, where the location of molecules or nanoscale constructs can be tracked in the body to report on disease or biochemical processes, is rapidly expanding to include combined modality or multimodal imaging. No single imaging technique can offer the optimum combination of properties (e.g. resolution, sensitivity, cost, availability). The rapid technological advances in hardware to scan patients, and software to process and fuse images, are pushing the boundaries of novel medical imaging approaches, and hand-in-hand with this is the requirement for advanced and specific multimodal imaging agents. These agents can be detected using a selection from radioisotope, magnetic resonance and optical imaging, among others. Nanoparticles offer great scope in this area as they lend themselves, via facile modification procedures, to act as multifunctional constructs. They have relevance as therapeutics and drug delivery agents that can be tracked by molecular imaging techniques with the particular development of applications in optically guided surgery and as radiosensitizers. There has been a huge amount of research work to produce nanoconstructs for imaging, and the parameters for successful clinical translation and validation of therapeutic applications are now becoming much better understood. It is an exciting time of progress for these agents as their potential is closer to being realized with translation into the clinic. The coming 5-10 years will be critical, as we will see if the predicted improvement in clinical outcomes becomes a reality. Some of the latest advances in combination modality agents are selected and the progression pathway to clinical trials analysed. This article is part of the themed issue 'Challenges for chemistry in molecular imaging'.

  12. Technetium-99m biliary imaging in pediatric surgical problems

    Sty, J.R.; Glicklich, M.; Babbitt, D.P.; Starshak, R.J.

    1981-01-01

    The results of scintigraphic imaging of the hepatobiliary system with 99mTc-PIPIDA (IDA derivative p-isopropylacetanilidoiminodiacetic acid) in forty children are reported. 99mTc-PIPIDA imaging is a noninvasive, rapid, safe examination that provides both functional and anatomical information about the hepatobiliary system. Although interpretation is limited by elevated direct serum bilirubin, this agent allows diagnostic information to be obtained with direct serum bilirubin levels up to 8 mg/dl

  13. Hepatobiliary imaging: the use of 99Tcsup(m)-pyridoxylidene glutamate scanning in jaundiced adults and infants

    Jenner, R.E.; Howard, E.R.; Clarke, M.B.; Barrett, J.J.

    1978-01-01

    99 Tcsup(m)-pyridoxylidene glutamate ( 99 Tcsup(m)-PG) scans have been carried out in 24 jaundiced adults (mean total bilirubin 255 μmol/1 and 11 infants with prolonged obstructive jaundice (mean total bilirubin 165 μmol/1). Absence of radioactivity in the gut was interpreted as complete biliary obstruction which was the cause of jaundice in ten adults and six infants. Using this criterion occlusion or patency of the bile ducts was correctly determined in 21 adults and eight infants. False-negative gut images found in one adult were and two infants, and three scans were inconclusive (two adults, one infant). The scan was unable to show details of the site of obstruction or pathology but the technique was simple and atraumatic and was safely performed in patients with serious complications, e.g. renal failure, coagulation defects, septicaemia. In infants the 99 Tcsup(m)-PG scan compared well with the 131 I rose bengal faecal excretion test and with liver biopsy in the investigation of prolonged obstructive jaundice. Repeat scans in infants with biliary atresia were used to assess post-operative bile drainage. It is suggested that 99 Tcsup(m)-PG scanning is a useful screening test in difficult cases of jaundice. It is especially useful in frail patients, and patients with complications. (author)

  14. Liposome imaging agents in personalized medicine

    Petersen, Anncatrine Luisa; Hansen, Anders Elias; Gabizon, Alberto

    2012-01-01

    In recent years the importance of molecular and diagnostic imaging has increased dramatically in the treatment planning of many diseases and in particular in cancer therapy. Within nanomedicine there are particularly interesting possibilities for combining imaging and therapy. Engineered liposomes...... that selectively localize in tumor tissue can transport both drugs and imaging agents, which allows for a theranostic approach with great potential in personalized medicine. Radiolabeling of liposomes have for many years been used in preclinical studies for evaluating liposome in vivo performance and has been...... start to consider how to use imaging for patient selection and treatment monitoring in connection to nanocarrier based medicines. Nanocarrier imaging agents could furthermore have interesting properties for disease diagnostics and staging. Here, we review the major advances in the development...

  15. Liposomes as carriers of imaging agents

    Caride, V.J.

    1985-01-01

    This review discusses the utilization of liposomes as imaging agents or as vehicles for contrast materials. The initial approach was the use of radiolabeled liposomes for scintigraphy. To this end liposomes were either labeled in the lipid membrane or aqueous radiotracers were incorporated inside the lipid vesicles. The lipid labeling provides a more stable association of the radioactive tracer and the lipid vesicles, while the use of water-soluble radiotracers provides a wider selection of compounds. Early attempts at selective tumor imaging using radiolabeled liposomes were unsuccessful. The use of monoclonal antibodies attached to liposomes offers new hopes. Several strategies have been proposed in this respect and several others can be envisioned. The use of liposomes permits the use of several administration routes for imaging agents. Of particular interest is the subcutaneous administration for lymph node visualization. Liposomes offer clear advantages over most radiocontrast agents for prolonged hepatosplenic contrast enhancement. This is particularly relevant in the diagnostic evaluation of the abdomen with computed tomography. Important research efforts are being conducted in this area. Two different approaches have been advanced: the incorporation of contrast agents into liposomes and the preparation of radiopaque liposomes from radiodense lipids. Nuclear magnetic resonance imaging can also benefit from contrast agents. Several centers are investigating this exciting field using liposomes loaded with paramagnetic elements.152 references

  16. Labelling and biodistribution of /sup 99m/Tc-ceftriaxone: a new imaging agent

    Khurshid, Z.; Roohi, S.; Zahoor, R.; Tariq, S.

    2012-01-01

    Most commonly used infection imaging agents are specific for inflammation. Some newer agents like labeled antimicrobials and peptides have shown infection seeking properties. Research is underway for synthesis of newer imaging agents specific for infections. In this quest we have labeled and bio evaluated /sup 99m/Tc-ceftriaxone. Ceftriaxone is a commonly used third generation cephalosporin antibiotic having a broad anti-bacterial spectrum but has more specificity for gram-negative bacteria. /sup 99m/Tc-ceftriaxone was prepared at ph 7 by adding 30 mg of ligand to /sup 99m/Tc in the presence of 50 mu g of SnCl/sub 2/./sup 2/H/sub 2/O. Boiling for ten minutes gave maximum labeling yield (96+1.76%). The stability at room temperature both with and without human serum was more than 90% till 24 hours. In-vitro binding revealed maximum binding of 68% and 47% with E.coli and S.aureus respectively after 4 hours incubation. Biodistribution studies in normal rats showed maximum uptake in hepatobiliary system followed by kidney. In infection and inflammation models the maximum target to non- target ratios of 12.66 +- 2.59, 2.36 +- 0.30 and 1.44 +- 0.53 were achieved with E. coli, S. aureus and oil inflammation respectively 4 hours post injection. Scintigraphic findings also correlated with biodistribution results. (Orig./A.B.)

  17. Imaging efficacy of a targeted imaging agent for fluorescence endoscopy

    Healey, A. J.; Bendiksen, R.; Attramadal, T.; Bjerke, R.; Waagene, S.; Hvoslef, A. M.; Johannesen, E.

    2008-02-01

    Colorectal cancer is a major cause of cancer death. A significant unmet clinical need exists in the area of screening for earlier and more accurate diagnosis and treatment. We have identified a fluorescence imaging agent targeted to an early stage molecular marker for colorectal cancer. The agent is administered intravenously and imaged in a far red imaging channel as an adjunct to white light endoscopy. There is experimental evidence of preclinical proof of mechanism for the agent. In order to assess potential clinical efficacy, imaging was performed with a prototype fluorescence endoscope system designed to produce clinically relevant images. A clinical laparoscope system was modified for fluorescence imaging. The system was optimised for sensitivity. Images were recorded at settings matching those expected with a clinical endoscope implementation (at video frame rate operation). The animal model was comprised of a HCT-15 xenograft tumour expressing the target at concentration levels expected in early stage colorectal cancer. Tumours were grown subcutaneously. The imaging agent was administered intravenously at a dose of 50nmol/kg body weight. The animals were killed 2 hours post administration and prepared for imaging. A 3-4mm diameter, 1.6mm thick slice of viable tumour was placed over the opened colon and imaged with the laparoscope system. A receiver operator characteristic analysis was applied to imaging results. An area under the curve of 0.98 and a sensitivity of 87% [73, 96] and specificity of 100% [93, 100] were obtained.

  18. Smart Contrast Agents for Magnetic Resonance Imaging.

    Bonnet, Célia S; Tóth, Éva

    2016-01-01

    By visualizing bioactive molecules or biological parameters in vivo, molecular imaging is searching for information at the molecular level in living organisms. In addition to contributing to earlier and more personalized diagnosis in medicine, it also helps understand and rationalize the molecular factors underlying physiological and pathological processes. In magnetic resonance imaging (MRI), complexes of paramagnetic metal ions, mostly lanthanides, are commonly used to enhance the intrinsic image contrast. They rely either on the relaxation effect of these metal chelates (T(1) agents), or on the phenomenon of paramagnetic chemical exchange saturation transfer (PARACEST agents). In both cases, responsive molecular magnetic resonance imaging probes can be designed to report on various biomarkers of biological interest. In this context, we review recent work in the literature and from our group on responsive T(1) and PARACEST MRI agents for the detection of biogenic metal ions (such as calcium or zinc), enzymatic activities, or neurotransmitter release. These examples illustrate the general strategies that can be applied to create molecular imaging agents with an MRI detectable response to biologically relevant parameters.

  19. Technetium-99m-labeled N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetic acid (/sup 99m/Tc HIDA): a new radiopharmaceutical for hepatobiliary imaging studies. [/sup 14/C, /sup 113/Sn

    Ryan, J.; Cooper, M.; Loberg, M.; Harvey, E.; Sikorski, S.

    1977-10-01

    An easily formulated, stable kit preparation of technetium-99m HIDA, suitable for use in humans, was developed and tested in mice and dogs. The tracer was cleared rapidly from the blood and excreted predominantly by the liver in both species. In dogs, the hepatobiliary clearance of Tc-99m HIDA was significantly greater than that of C-14 HIDA and Sn-113 HIDA. The LD/sub 50/ for HIDA in mice, 168 mg/kg, exceeded the average human dose by a factor of 1000 on a per-weight basis. Blood clearance curves for Tc-99m HIDA in 12 normal subjects were biexponential with half-times of 4.6 +- 1.0 min and 31.5 +- 7.0 min, and cumulative 90-min urine samples contained 14.2 +- 1.8% of the injected dose. Images in normal subjects and nonjaundiced patients showed rapid concentration of tracer by the liver and activity was present within the biliary system in 10 to 20 min. In jaundiced patients, the tracer blood clearance was delayed and urinary excretion increased, but intestinal activity, indicating biliary patency, was imaged in those patients without complete focal obstruction of the common duct. Technetium-99m HIDA is a nontoxic radiopharmaceutical useful for clinical evaluation of hepatobiliary disorders in humans.

  20. Contrasts agents in magnetic resonance imaging

    Bonnet, P.A.; Fernandez, J.P.; Milhavet, J.C.; Chapat, J.P.; Almes, C.; Bruel, J.M.; Rouanet, J.P.; Lamarque, J.L.

    1984-01-01

    Changing different parameters involved in imaging procedures, paramagnetic substances provide contrast enhancement in MRI. Contrast agents presently studied in animals and clinical trials, are either salts or complexes of mineral ions either nitroxide stable free radicals. Their development should extend the possibilities of tissular characterization and fonctional or metabolic evaluation of the MRI [fr

  1. Contrast agents in magnetic resonance imaging

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  2. Modular strategies for PET imaging agents

    Hooker, J.M.

    2010-01-01

    In recent years, modular and simplified chemical and biological strategies have been developed for the synthesis and implementation of positron emission tomography (PET) radiotracers. New developments in bioconjugation and synthetic methodologies, in combination with advances in macromolecular delivery systems and gene-expression imaging, reflect a need to reduce radiosynthesis burden in order to accelerate imaging agent development. These new approaches, which are often mindful of existing infrastructure and available resources, are anticipated to provide a more approachable entry point for researchers interested in using PET to translate in vitro research to in vivo imaging.

  3. Nanoparticles as image enhancing agents for ultrasonography

    Liu Jun [Biomedical Engineering Department, Ohio State University, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH 43210 (United States); Levine, Andrea L [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Mattoon, John S [Department of Veterinary Clinical Sciences, Ohio State University, 1151 Veterinary Hospital, 601 Vernon Tharp St., Columbus, OH 43210 (United States); Yamaguchi, Mamoru [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States); Lee, Robert J [Division of Pharmaceutics, College of Pharmacy, NCI Comprehensive Cancer Center, and NSF Nanoscale Science and Engineering Center, Ohio State University, 500 West 12th Avenue, Columbus, OH 43210 (United States); Pan Xueliang [Department of Statistics, Ohio State University, 1958 Neil Avenue, Columbus, OH 43210 (United States); Rosol, Thomas J [Department of Veterinary Biosciences, Ohio State University, 1925 Coffey Rd, Columbus, OH 43210 (United States)

    2006-05-07

    Nanoparticles have drawn great attention as targeted imaging and/or therapeutic agents. The small size of the nanoparticles allows them to target cells that are beyond capillary vasculature, such as cancer cells. We investigated the effect of solid nanoparticles for enhancing ultrasonic grey scale images in tissue phantoms and mouse livers in vivo. Silica nanospheres (100 nm) were dispersed in agarose at 1-2.5% mass concentration and imaged by a high-resolution ultrasound imaging system (transducer centre frequency: 30 MHz). Polystyrene particles of different sizes (500-3000 nm) and concentrations (0.13-0.75% mass) were similarly dispersed in agarose and imaged. Mice were injected intravenously with nanoparticle suspensions in saline. B-mode images of the livers were acquired at different time points after particle injection. An automated computer program was used to quantify the grey scale changes. Ultrasonic reflections were observed from nanoparticle suspensions in agarose gels. The image brightness, i.e., mean grey scale level, increased with particle size and concentration. The mean grey scale of mouse livers also increased following particle administration. These results indicated that it is feasible to use solid nanoparticles as contrast enhancing agents for ultrasonic imagin000.

  4. Surgical, pathological and clinical correlation of Tc-99m DISIDA hepatobiliary imaging in 138 adult males, in the diagnosis of functional cystic duct obstruction VS acute or chronic cholecystitis

    Yoo, J.H.K.; Beal, W.H.; Ware, R.W.; Straw, J.D.; Chaudhuri, T.K.

    1985-01-01

    Despite the wide acceptance of the hepatobiliary scintigraphy as a popular diagnostic imaging modality for gallbladder and hepatobiliary disease, correlation between radionuclide diagnoses and the final clinical and/or pathologic findings have not been thoroughly evaluated. The lack of correlative studies frequently generates difficulties in making appropriate diagnostic interpretation of the objective findings. A retrospective clinical pathological and surgical correlative study was undertaken by the authors in 138 male veteran patients, who underwent computer assisted minute by minute Tc-99m DISIDA cholescintigraphy. A very high percentage (75%) revealed abnormalities; non-visualization of gallbladder (GB) with normal choledochus system (46%), choledochal obstruction with no GB visualization (13%), choledochal obstruction with normal GB visualization (6%), severe hepatocellular disease with non-diagnostic GB (4%), and delayed GB visualization (longer than 60 minutes) (3%). Non-visualization of GB but normal choledochus demonstrated diverse pathologic etiologies, acute and chronic cholecystitis (64%), S/P cholecystectomy (8%), functional obstruction secondary to sepsis or pancreatitis (6%), and various other pathologies including porcelain GB and cholangitis (22%). The most important cause of choledochal obstruction was mass lesions or local infiltration with metastases (33%) rather than acute cholecystitis (27%). Although the sensitivity (98%) and specificity (92%) for cystic duct obstruction were very high, the specificity decreases significantly for cholecystitis

  5. Hepatobiliary fascioliasis: a case with unusual radiological features.

    Yeşildağ, Ahmet; Senol, Altuğ; Köroğlu, Mert; Koçkar, Cem; Oyar, Orhan; Işler, Mehmet

    2010-12-01

    We report a case of hepatobiliary fascioliasis presenting with unusual radiological findings that have not been reported previously. Imaging studies revealed hepatic cystic pouches communicating with intrahepatic bile ducts. Snail-like, oval shaped and conglomerated echogenic particles with no acoustic shadowing, suggesting F. hepatica, were detected in these cystic pouches. In addition, secondary sclerosing cholangitis developed after fascioliasis.

  6. Sphincter of Oddi stenosis: diagnosis using hepatobiliary scintigraphy and endoscopic manometry

    Lee, R.G.L.; Gregg, J.A.; Koroshetz, A.M.; Hill, T.C.; Clouse, M.E.

    1985-01-01

    To determine the role of radionuclide imaging in diagnosing sphincter of Oddi stenosis, 21 patients with symptoms suggesting this disorder underwent endoscopic retrograde cholangiopancreatography, cholescintigraphy, and, when possible, endoscopic manometry. Those patients with abnormal hepatobiliary scintigraphy results had a mean basal sphincter pressure of 38.5 mm Hg. Sphincter pressures could not be measured in six patients with sphincters too tight to cannulate. Ten patients who underwent hepatobiliary scanning both before and after sphincter surgery had normal scan results of the repeat study. Hepatobiliary imaging appears useful for diagnosis of sphincter of Oddi stenosis in selected patients in whom manometry cannot be performed and for objective assessment of response to therapy

  7. Manganese and Gd-DTPA stearyl liposomes as reticuloendothelial-system-specific MR imaging contrast agents

    Wuthrich, R.; Schwendener, R.; Duewell, S.; VonSchulthess, G.K.; Fuchs, W.A.

    1988-01-01

    Liposomes can be used to target metal ions as MR contrast agents to liver and spleen. It was the aim of this work to examine unilamellar liposomes containing manganese and gadolinium ions with respect to their targetting ability, contrast enhancement, and in vivo kinetics in rats and dogs. Unilamellar liposomes containing DTPA stearate were complexed with Mn/sup 2+/ and Gd/sup 3+/ resulting in vesicles of 30-40 nm. Injected into rats, approximately 35% of manganese liposomes were present in the liver after 30-60 minutes, and after 24 hours more than 80% had been eliminated. The pharmacokinetics of gadolinium were more protracted. In MR imaging, a reduction in the T1 of the liver parenchyma from 450 to 170 and 280 msec was observed for manganese and gadolinium liposomes (0.03 mmol/kg body weight), respectively, with the liver appearing as bright as fat. Manganese (and Gd-DTPA) stearyl liposomes are potential organ-selective contrast agents for liver and spleen and are eliminated through a hepatobiliary route

  8. PIPIDA excretory scintigraphy in the diagnosis of hepatobiliary disorders

    Pelot, D.; Berk, J.E.; Wistow, B.W.; Morton, M.E.

    1981-01-01

    The diagnostic accuracy of hepatobiliary radionuclide imaging using 99 mTC-labeled para-isopropyl acetanilido-iminodiacetic acid ( 99 mTc-PIPIDA) in patients with hepatobiliary disorders was assessed in 50 patients. Thirty of the study group were jaundiced; the remaining 20 had other clinical features suggestive of some hepatobiliary disorder. The findings using PIPIDA proved to be correct in 22 (73%) of the 30 jaundiced patients and in 18 (90%) of 20 patients without jaundice. There appears to be a close relationship between the diagnostic accuracy of the test and the level of serum bilirubin. Thus, the diagnosis indicated by the PIPIDA test was correct in 30 (88%) of 34 patients in whom the serum bilirubin was less than 5 mg./dl. but only in 10 (62%) of 16 patients whose serum bilirubin exceeded 5 mg./dl. It is concluded from these observations that: 1. PIPIDA is diagnostically useful in the evaluation of hepatobiliary disorders, especially when the serum bilirubin is less than 5 mg./dl. and 2. the accuracy of this test is not absolute and the findings are not always definitive

  9. Specific preoperative diagnosis of choledochal cysts by combined sonography and hepatobiliary scintigraphy

    Papanicolaou, N.; Abramson, S.J.; Teele, R.L.; Treves, S.

    1985-01-01

    The combined use of sonography and hepatobiliary scintigraphy correctly identified a choledochal cyst preoperatively in seven consecutive infants and children. The high resolution anatomic images provided by sonography coupled with physiologic data on filing of the cyst, biliary patency and liver function derived from radionuclide scanning offer valuable information in the diagnosis and planning of corrective surgery of the cyst and coexisting hepatobiliary anomalies. Invasive diagnostic procedures should be reserved for occasional problematic cases [fr

  10. Evaluation of reserved hepatic function in patients with hepatobiliary tumor by {sup 99m}Tc-GSA. Effect of hyperbilirubinemia and usefulness of regional reserved hepatic functional imaging

    Jin Wu; Ishikawa, Nobuyoshi; Takeda, Tohoru; Sato, Motohiro; Todoroki, Takeshi; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Fukunaga, Kiyoshi; Okumura, Toshiyuki; Hatakeyama, Rokurou

    1996-02-01

    The evaluation of the reserved hepatic function was performed by {sup 99m}Tc-galactosyl serum albumin ({sup 99m}Tc-GSA) in 70 patients with hepatobiliary tumor. The dynamic study was performed to evaluate global reserved hepatic function following the intravenous bolus injection of {sup 99m}Tc-GSA, and the hepatic single photon emission computed tomography (SPECT) was obtained to assess the regional reserved hepatic function. The functional hepatic index (LHL{sub 15}) was derived from liver time-activity data, and it was compared with serum total-bilirubin level, serum albumin level and plasma disappearance rate of indocyanine green (ICG{sub 15}). In the patients with hepatocellular carcinoma, LHL{sub 15} value agreed well with ICG{sub 15} value, serum total-bilirubin level, and serum albumin level. Moderate or severe hepatic dysfunction was observed at 65.4% of these patients. In the patients with cholangiocellular carcinoma, a discrepancy of LHL{sub 15} value and ICG{sub 15} value was observed. Increment of the ICG{sub 15} value was correlated with that of the serum total-bilirubin level, whereas the correlation was not observed between the LHL{sub 15} value and the serum total-bilirubin level. These results indicate that {sup 99m}Tc-GSA scintigraphy can evaluate the reserved hepatic function without the embellishment of jaundice. This method is useful for assessing the global and regional reserved hepatic function. (author).

  11. Evaluation of reserved hepatic function in patients with hepatobiliary tumor by 99mTc-GSA. Effect of hyperbilirubinemia and usefulness of regional reserved hepatic functional imaging

    Jin Wu; Ishikawa, Nobuyoshi; Takeda, Tohoru; Sato, Motohiro; Todoroki, Takeshi; Itai, Yuji; Fukunaga, Kiyoshi; Okumura, Toshiyuki; Hatakeyama, Rokurou.

    1996-01-01

    The evaluation of the reserved hepatic function was performed by 99m Tc-galactosyl serum albumin ( 99m Tc-GSA) in 70 patients with hepatobiliary tumor. The dynamic study was performed to evaluate global reserved hepatic function following the intravenous bolus injection of 99m Tc-GSA, and the hepatic single photon emission computed tomography (SPECT) was obtained to assess the regional reserved hepatic function. The functional hepatic index (LHL 15 ) was derived from liver time-activity data, and it was compared with serum total-bilirubin level, serum albumin level and plasma disappearance rate of indocyanine green (ICG 15 ). In the patients with hepatocellular carcinoma, LHL 15 value agreed well with ICG 15 value, serum total-bilirubin level, and serum albumin level. Moderate or severe hepatic dysfunction was observed at 65.4% of these patients. In the patients with cholangiocellular carcinoma, a discrepancy of LHL 15 value and ICG 15 value was observed. Increment of the ICG 15 value was correlated with that of the serum total-bilirubin level, whereas the correlation was not observed between the LHL 15 value and the serum total-bilirubin level. These results indicate that 99m Tc-GSA scintigraphy can evaluate the reserved hepatic function without the embellishment of jaundice. This method is useful for assessing the global and regional reserved hepatic function. (author)

  12. Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging.

    Daryaei, Iman; Pagel, Mark D

    2015-01-01

    Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a "double-agent" approach to molecular imaging. Exogenous T 2 -exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T 1 and T 2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as "secret agents" in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging.

  13. Hypovascular hypointense nodules on hepatobiliary phase without T2 hyperintensity on gadoxetic acid-enhanced MR images in patients with chronic liver disease: long-term outcomes and risk factors for hypervascular transformation

    Kim, Yong Seek [Chonbuk National University Medical School and Hospital, Department of Radiology, Jeonju-si, Chonbuk (Korea, Republic of); Song, Ji Soo; Lee, Hyun Kyung; Han, Young Min [Chonbuk National University Medical School and Hospital, Department of Radiology, Jeonju-si, Chonbuk (Korea, Republic of); Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Research Institute of Clinical Medicine, Chonbuk (Korea, Republic of)

    2016-10-15

    To evaluate the long-term outcomes and imaging features associated with hypervascularization of hypovascular nodules that show T2 iso-/hypointensity and hypointensity on hepatobiliary phase (HBP) of gadoxetic acid-enhanced magnetic resonance (MR) images in patients with chronic liver disease. Sixty patients and 114 nodules, which were hypovascular and iso-/hypointense on T2-weighted images and hypointense on HBP of gadoxetic acid-enhanced MRI, were included. We evaluated the effect of baseline clinical features, baseline MR features and growth rate on subsequent hypervascularization. Twenty-seven nodules in 21 patients transformed to hypervascular hepatocellular carcinoma (HCC). Using multivariate Cox analysis, T1 hyperintensity (hazard ratio [HR] = 2.69, P = 0.021), previous history of HCC (HR = 2.64, P = 0.021), and initial nodule size (HR = 1.09, P = 0.046) were identified to be associated with hypervascularization. The growth rate of nodules was a more powerful determinant of subsequent hypervascularization than baseline clinical and MR features. At long-term follow-up after >3 years, only one nodule with T1 isointensity showed hypervascularization. Careful follow-up or diagnostic procedures, such as biopsy, should be considered for up to 3 years after detection of hypointense nodules on HBP with T1 hyperintensity or a higher growth rate. (orig.)

  14. Comparison of several potential myocardial imaging agents

    Watson, E.E.; Stabin, M.G.; Goodman, M.M.; Knapp, F.F. Jr.; Srivastava, P.C.

    1985-01-01

    Although myocardial imaging is currently dominated by Tl-201, several alternative agents with improved physiologic or radionuclidic properties have been proposed. Based on human and animal studies in the literature, the metabolism of several of these compounds was studied for the purpose of generating radiation dose estimates. Dose estimates are listed for several I-123 labeled free fatty acids, an I-123 labeled phosphonium compound, Rb-82, Cu-64, F-18 FDG (all compounds which are taken up by the normal myocardium), and for Tc-99m pyrophosphate (PYP) (which localizes in myocardial infarcts). Dose estimates could not be generated for C-11 palmitate, but this compound was included in a comparison of myocardial retention times. For the I-123 labeled compounds, I-124 was included as a contaminant in generating the dose estimates. Radiation doses were lowest for Rb-82 (gonads 0.3 to 0.5 μGy/MBq, heart wall 15 μGy/MBq). Doses for the I-123 labeled fatty acids were similar to one another, with IPPA being the lowest (gonads 20 μGy/MBq, heart wall 15 μGy/MBq). Doses for Tc-99m PYP were also low (gonads 4 to 7 μGy/MBq, heart wall 4 μGy/MBq, skeleton 15 μGy/MBq). The desirability of these compounds is discussed briefly, considering half life, imaging mode and energy, and dosimetry, including a comparison of the effective whole body dose equivalents. 34 refs., 11 tabs

  15. Radiology illustrated. Hepatobiliary and pancreatic radiology

    Choi, Byung Ihn

    2014-01-01

    Clear, practical guide to the diagnostic imaging of diseases of the liver, biliary tree, gallbladder, pancreas, and spleen. A wealth of carefully selected and categorized illustrations. Highlighted key points to facilitate rapid review. Aid to differential diagnosis. Radiology Illustrated: Hepatobiliary and Pancreatic Radiology is the first of two volumes that will serve as a clear, practical guide to the diagnostic imaging of abdominal diseases. This volume, devoted to diseases of the liver, biliary tree, gallbladder, pancreas, and spleen, covers congenital disorders, vascular diseases, benign and malignant tumors, and infectious conditions. Liver transplantation, evaluation of the therapeutic response of hepatocellular carcinoma, trauma, and post-treatment complications are also addressed. The book presents approximately 560 cases with more than 2100 carefully selected and categorized illustrations, along with key text messages and tables, that will allow the reader easily to recall the relevant images as an aid to differential diagnosis. At the end of each text message, key points are summarized to facilitate rapid review and learning. In addition, brief descriptions of each clinical problem are provided, followed by both common and uncommon case studies that illustrate the role of different imaging modalities, such as ultrasound, radiography, CT, and MRI.

  16. Radiology illustrated. Hepatobiliary and pancreatic radiology

    Choi, Byung Ihn (ed.) [Seoul National Univ. Hospital (Korea, Republic of). Dept. of Radiology

    2014-04-01

    Clear, practical guide to the diagnostic imaging of diseases of the liver, biliary tree, gallbladder, pancreas, and spleen. A wealth of carefully selected and categorized illustrations. Highlighted key points to facilitate rapid review. Aid to differential diagnosis. Radiology Illustrated: Hepatobiliary and Pancreatic Radiology is the first of two volumes that will serve as a clear, practical guide to the diagnostic imaging of abdominal diseases. This volume, devoted to diseases of the liver, biliary tree, gallbladder, pancreas, and spleen, covers congenital disorders, vascular diseases, benign and malignant tumors, and infectious conditions. Liver transplantation, evaluation of the therapeutic response of hepatocellular carcinoma, trauma, and post-treatment complications are also addressed. The book presents approximately 560 cases with more than 2100 carefully selected and categorized illustrations, along with key text messages and tables, that will allow the reader easily to recall the relevant images as an aid to differential diagnosis. At the end of each text message, key points are summarized to facilitate rapid review and learning. In addition, brief descriptions of each clinical problem are provided, followed by both common and uncommon case studies that illustrate the role of different imaging modalities, such as ultrasound, radiography, CT, and MRI.

  17. Hepatobiliary

    ... placed over the patient's body. SPECT involves the rotation of the gamma camera heads around the patient's ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  18. Variants of hepatobiliary leakage: Biloma and aberrant drainage paths - case report

    Mack, J M; Peracha, H; Sziklas, J J; Rosenberg, R J; Spencer, R P

    1987-04-01

    Three variants of abnormal biliary drainage, on Tc-99m-DIPIDA studies, were illustrated, despite patency of the normal pathway. A 23-year-old man had gun shot fragments removed from the liver. An area originally negative for uptake of the hepatobiliary agent later demonstrated an increased content after the remainder of the liver had drained (a biloma). A 67-year-old woman showed passage of Tc-99m-DIPIDA simultaneously from 2 pathways. One was via a biliary-cutaneous fistula site along a prior T-tube tract, and the other was into the small intestine via a biliary stent. Following cholecystectomy, a hepatobiliary study in a 46-year-old man revealed a 'gallbladder'. This represented leakage into the prior gallbladder bed. The hepatobiliary agents can exit via traumatically or surgically created pathways, even when the 'usual' anatomic drainage is present.

  19. Magnetic Resonance Imaging Contrast Agents: A Review of Literature

    Zahra Sahraei

    2015-10-01

    Full Text Available  Magnetic Resonance Imaging (MRI contrast agents most commonly agents used in diagnosing different diseases. Several agents have been ever introduced with different peculiar characteristics. They vary in potency, adverse reaction and other specification, so it is important to select the proper agent in different situations. We conducted a systematic literature search in MEDLINE/PUBMED, Web of Science (ISI, Scopus,Google Scholar by using keywords "gadolinium" and "MRI contrast Medias", "Gadofosvest", "Gadobenate" and "Gadoxetate". The most frequent contrast media agents made based on gadolinium (Gd. These are divided into two categories based on the structure of their chelating parts, linear agents and macrocyclic agents. All characteristics of contrast media factors, including efficiency, kinetic properties, stability, side effects and the rate of resolution are directly related to the structure of chelating part of that formulation.In vitro data has shown that the macrocyclic compounds are the most stable Gd-CA as they do not bind to serum proteins, they all possess similar and relatively low relaxivity and the prevalence of Nephrogenic Systemic Fibrosis (NSF has decreased by increasing the use of macrocyclic agents in recent years. No cases of NSF have been recorded after the administration of any of the high-relaxivity protein interacting agents, the vascular imaging agent gadofosveset trisodium (Ablavar, the hepatic imaging agent gadoxetate meglumine (Eovist, and the multipurpose agent gadobenate dimeglumine (MultiHance. In pregnancy and lactating women, stable macrocyclic agent is recommended.

  20. Preparation and animal studies of 99Tcm-TRODAT-1 as a dopamine transporter imaging agent

    Fang Ping; Wu Chunying; Chen Zhengping; Zhou Xiang; Wan Weixing; Ji Shuren

    1999-01-01

    Objective: To develop 99 Tc m labelled dopamine transporter (DAT) imaging agent 99 Tc m -(2β-[N,N'-bis(2-mercaptoethyl) ethylenediamin] methyl, 3β-(4-chlorophenyl) tropane (TRODAT-1) for evaluating changes of DAT in patients with Parkinson's disease. Methods: TRODAT-1 was synthesized from cocaine by stepwise reactions adding two aminoethanethiol units. Using SnCl 2 as reducing agent, and in the presence of Naglucoheptonate, 99 Tc m -TRODAT-1 was prepared. Animal studies have been performed in rats and normal monkeys. Results: The structure of TRODAT-1 was confirmed by IR, 1 HNMR and MS. Radiochemical purity of 99 Tc m -TRODAT-1 was over 90%, and stable for 24 h at room temperature. The partition coefficient in octanol and buffer was 132 and 154 at pH 7.0 and 7.4 respectively. Biodistribution displayed relatively low uptake in rat brain (0.28 and 0.12% ID/org at 2 min and 60 min post injection, respectively), but high uptake in liver (16.7% ID/organ at 60 min), steady uptake in kidney (maintained 3% ID/organ). The major radioactivity was excreted by hepatobiliary systems. The distribution in rat's brain showed that striatal uptake were 0.193, 0.189, 0.142 and 0.136% ID/g at 2, 30, 60 and 120 min, respectively. The ratios of striatal to cerebellar, striatal to hippocampal and striatal to cortical were 4.45 2.55 and 3.15 at 120 min post injection, respectively. Brain image studies in monkeys indicated that TRODAT was uptake and retained in the basal ganglia, where containing DAT abundantly. Ratio of regional brain uptakes of striatum/cerebellum was 1.56 as measured by SPECT imaging at 120 min. Conclusions: Above results showed the stable, neutral and lipophilic complex 99 Tc m -TRODAT-1 can cross the blood brain barrier, and be selectively concentrated by the striatal area, where containing DAT abundantly. High quality images of monkeys were also obtained. It suggested that 99 Tc m -TRODAT-1 may be a promising agent for clinical application

  1. Application status of three-dimensional CT reconstruction in hepatobiliary surgery

    JIANG Chao

    2017-02-01

    Full Text Available With the development of imaging technology, three-dimensional CT reconstruction has been widely used in hepatobiliary surgery. Three-dimensional CT reconstruction can divide and reconstruct two-dimensional images into three-dimensional images and clearly show the location of lesion and its relationship with the intrahepatic bile duct system. It has an important value in the preoperative assessment of liver volume, diagnosis and treatment decision-making process, intraoperative precise operation, and postoperative individualized management, and promotes the constant development of hepatobiliary surgery and minimally invasive technology, and therefore, it holds promise for clinical application.

  2. Intelligent Design of Nano-Scale Molecular Imaging Agents

    Takeaki Ozawa

    2012-12-01

    Full Text Available Visual representation and quantification of biological processes at the cellular and subcellular levels within living subjects are gaining great interest in life science to address frontier issues in pathology and physiology. As intact living subjects do not emit any optical signature, visual representation usually exploits nano-scale imaging agents as the source of image contrast. Many imaging agents have been developed for this purpose, some of which exert nonspecific, passive, and physical interaction with a target. Current research interest in molecular imaging has mainly shifted to fabrication of smartly integrated, specific, and versatile agents that emit fluorescence or luminescence as an optical readout. These agents include luminescent quantum dots (QDs, biofunctional antibodies, and multifunctional nanoparticles. Furthermore, genetically encoded nano-imaging agents embedding fluorescent proteins or luciferases are now gaining popularity. These agents are generated by integrative design of the components, such as luciferase, flexible linker, and receptor to exert a specific on–off switching in the complex context of living subjects. In the present review, we provide an overview of the basic concepts, smart design, and practical contribution of recent nano-scale imaging agents, especially with respect to genetically encoded imaging agents.

  3. Radiolabelled spiroperidol: Possible pituitary adenoma imaging agent

    Otto, C.A.; Marshall, J.C.; Lloyd, R.V.; Sherman, P.S.; Wieland, D.M.

    1984-01-01

    Prolactin-secreting pituitary adenomas are the most common type of pituitary tumors. Detection currently depends on physical symptoms, elevated serum prolactin levels and CT scans. An imaging agent which specifically localized in prolactinomas based on some functional characteristic of the tumor would be of considerable clinical value not only for early detection but also for monitoring of therapy. Tritiated spiroperidol ( 3 H-Sp) was selected for evaluation based on 1) the presence of D-2 receptors in normal anterior pituitary and adenoma tissue and 2) the high affinity of spiroperidol for D-2 receptors. Recent data have established that implantation of diethylstilbestrol (DES) in Fischer F344 rats induced prolactin-secreting tumors in the pituitary. 3 HSp was evaluated in pituitary tissue of both control and DES-treated rats. 3 HSp concentration in normal female anterior pituitary tissue was found to be about 0.27% kg dose/g from 5 min to 4hrs. This value was about 10 times levels in cortex, cerebellum and striatum. In DES-treated rats the % kg dose/g values remained approximately the same. A 5-fold increase in serum prolactin was associated with a 6-fold increase in both pituitary weight and % dose/organ. The data suggests that although total pituitary weight has increased due to tumor growth (reflected in increased values for % dose/organ), the relative number of receptors per g of tissue has remained constant. This result is in agreement with observations of others on D-2 receptor concentration in prolactinomas

  4. Fundamental study of DSA images using gadolinium contrast agent

    Nagashima, Hiroyuki; Shiraishi, Akihisa; Igarashi, Hitoshi; Sakamoto, Hajime; Sano, Yoshitomo

    2002-01-01

    Most contrast agents used in digital subtraction angiography (DSA) are non-ionic iodinated contrast agents, which can cause severe side effects in patients with contraindications for iodine or allergic reactions to iodine. Therefore, DSA examinations using carbon dioxide gas or examinations done by magnetic resonance imaging (MRI) and ultrasound (US) were carried out in these patients. However, none of these examinations provided mages as clear as those of DSA with an iodinated contrast agent. We experienced DSA examination using a gadolinium contrast agent in a patient contraindicated for iodine. The patient had undergone MRI examination with a gadolinium contrast agent previously without side effects. The characteristics of gadolinium and the iodinated contrast agent were compared, and the DSA images obtained clinically using these media were also evaluated. The signal-to-noise (SN) ratio of the gadolinium contrast agent was the highest at tube voltages of 70 to 80 kilovolts and improved slightly when the image intensifier (I.I.) entrance dose was greater than 300 μR (77.4 nC/kg). The dilution ratios of five iodinated contrast agents showed the same S/N value as the undiluted gadolinium contrast agent. Clinically, the images obtained showed a slight decrease in contrast but provided the data necessary to make a diagnosis and made it possible to obtain interventional radiology (IVR) without any side effects. DSA examinations using a gadolinium contrast agent have some benefit with low risk and are thought to be useful for patients contraindicated for iodine. (author)

  5. sup(99m)Tc-pyridoxylidene glutamate - a radiopharmaceutical for the hepatobiliary system

    Noronha, O.P.D.; Sewatkar, A.B.; Ganatra, R.D.; Subramanian, G.

    1976-01-01

    sup(99m)Tc-pyridoxylidene glutamate is a good agent to visualize the hepatobiliary system. The method of preparation and quality control, and preliminary data on its behaviour in human controls is presented. In humans the gall bladder could be well seen in about 15-20 minutes after intravenous injection. (orig.) [de

  6. Magnetic resonance imaging contrast agents: Overview and perspectives

    Yan Guoping; Robinson, Leslie; Hogg, Peter

    2007-01-01

    Magnetic resonance imaging (MRI) is a non-invasive clinical imaging modality, which has become widely used in the diagnosis and/or staging of human diseases around the world. Some MRI examinations include the use of contrast agents. The categorizations of currently available contrast agents have been described according to their effect on the image, magnetic behavior and biodistribution in the body, respectively. In this field, superparamagnetic iron oxide particles and soluble paramagnetic metal chelates are two main classes of contrast agents for MRI. This review outlines the research and development of MRI contrast agents. In future, the ideal MRI contrast agent will be focused on the neutral tissue- or organ-targeting materials with high relaxivity and specificity, low toxicity and side effects, suitable long intravascular duration and excretion time, high contrast enhancement with low dose in vivo, and with minimal cost

  7. Development of a Multifaceted Ovarian Cancer Therapeutic and Imaging Agent

    Markland, Francis S

    2008-01-01

    ...%. This project outlines the development of a recombinant version of a member of a class of proteins known as disintegrins as an innovative imaging and diagnostic agent for ovarian cancer (OC). Vicrostatin (VN...

  8. Quinone-fused porphyrins as contrast agents for photoacoustic imaging

    Banala, Srinivas; Fokong, Stanley; Brand, Christian; Andreou, Chrysafis; Krä utler, Bernhard; Rueping, Magnus; Kiessling, Fabian

    2017-01-01

    Photoacoustic (PA) imaging is an emerging non-invasive diagnostic modality with many potential clinical applications in oncology, rheumatology and the cardiovascular field. For this purpose, there is a high demand for exogenous contrast agents

  9. Modified natural nanoparticles as contrast agents for medical imaging

    Cormode, David P.; Jarzyna, Peter A.; Mulder, Willem J. M.; Fayad, Zahi A.

    2010-01-01

    The development of novel and effective contrast agents is one of the drivers of the ongoing improvement in medical imaging. Many of the new agents reported are nanoparticle-based. There are a variety of natural nanoparticles known, e.g. lipoproteins, viruses or ferritin. Natural nanoparticles have

  10. Improved radionuclide bone imaging agent injection needle withdrawal method can improve image quality

    Qin Yongmei; Wang Laihao; Zhao Lihua; Guo Xiaogang; Kong Qingfeng

    2009-01-01

    Objective: To investigate the improvement of radionuclide bone imaging agent injection needle withdrawal method on whole body bone scan image quality. Methods: Elbow vein injection syringe needle directly into the bone imaging agent in the routine group of 117 cases, with a cotton swab needle injection method for the rapid pull out the needle puncture point pressing, pressing moment. Improvement of 117 cases of needle injection method to put two needles into the skin swabs and blood vessels, pull out the needle while pressing two or more entry point 5min. After 2 hours underwent whole body bone SPECT imaging plane. Results: The conventional group at the injection site imaging agents uptake rate was 16.24%, improved group was 2.56%. Conclusion: The modified bone imaging agent injection needle withdrawal method, injection-site imaging agent uptake were significantly decreased whole body bone imaging can improve image quality. (authors)

  11. Cardiac image segmentation for contrast agent videodensitometry

    Mischi, M.; Kalker, A.A.C.M.; Korsten, H.H.M.

    2005-01-01

    Indicator dilution techniques are widely used in the intensive care unit and operating room for cardiac parameter measurements. However, the invasiveness of current techniques represents a limitation for their clinical use. The development of stable ultrasound contrast agents allows new applications

  12. Evaluation of potential gastrointestinal contrast agents for echoplanar MR imaging

    Reimer, P.; Schmitt, F.; Ladebeck, R.; Graessner, J.; Schaffer, B.

    1993-01-01

    The purpose of this study was to investigate approved aqueous gastrointestinal contrast agents for use in abdominal EPI. Conventional and echoplanar MR imaging experiments were performed with 1.0 Tesla whole body systems. Phantom measurements of Gastrografin, barium sulfate suspension, oral gadopentetate dimeglumine, water, and saline were performed. Signal intensity (SI) of aqueous oral barium sulfate and iodine based CT contrast agents was lower on conventional spin-echo (SE), Flash, and Turbo-Flush images than on EP images. The contrast agents exhibited higher SI on T2-weighted SE PE images and TI-time dependence on inversion recovery EP-images. The barium sulfate suspension was administered in volunteers to obtain information about bowel lumen enhancement and susceptibility artifacts. Oral administration of the aqueous barium sulfate suspension increased bowel lumen signal and reduced susceptibility artifacts. (orig.)

  13. Tissue-specific MR contrast agents. Impact on imaging diagnosis and future prospects

    Yoshimitsu, Kengo; Nakayama, Tomohiro; Kakihara, Daisuke; Irie, Hiroyuki; Tajima, Tsuyoshi; Asayama, Yoshiki; Hirakawa, Masakazu; Ishigami, Kousei; Honda, Hiroshi

    2005-01-01

    Superparamagnetic iron oxide (SPIO) is the only tissue-specific MR agent currently available in Japan. It is quickly taken up by Kupffer cells at the first pass (either arterial or portal) and becomes clustered in the lysosome, providing characteristic T2 * and T2 shortening effects that suppresses the signal of normal or non-tumorous liver tissue. SPIO has dramatically changed the diagnostic algorithm of liver metastasis in clinical practice, now serving as the gold standard instead of CT during arterial portography (CTAP). Its role in the diagnosis of hepatocellular carcinoma (HCC), however, is somewhat complicated, owing to its heterogeneous uptake by the background cirrhotic liver, as well as by some of the HCCs themselves. It has been shown to be useful in the diagnosis of pseudolesions (arterioportal shunts) and some benign hepatocellular lesions (focal nodular hyperplasia or adenoma) by their complete or partial uptake of SPIO, in contrast to an absence of uptake by true liver lesions. It has also been suggested that the histological grade of HCC affects the degree of SPIO uptake. Thus, SPIO serves as a complementary tool to the primary modalities of vascular survey, namely, dynamic CT/MR and CT during hepatic arteriography (CTHA)/CTAP, in the diagnosis of HCC. Gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) is a novel hepatobiliary contrast agent that is not yet available but is supposed to be approved by the Ministry of Health, Labour, and Welfare of Japan in the near future. It is taken up by hepatocytes and excreted into the bile, providing a T1-shortening effect that enhances the normal or non-tumorous liver tissue. It has also been shown to have the effect of positive enhancement of hypervascular liver tumors on the arterial phase, just like the usual extracellular contrast agent (gadopentetate dimeglumine: Gd-DTPA). Thus, Gd-EOB-DTPA was once thought to be an ideal contrast agent for liver tumors, providing information on both

  14. 64Cu loaded liposomes as positron emission tomography imaging agents

    Petersen, Anncatrine Luisa; Binderup, Tina; Rasmussen, Palle

    2011-01-01

    applicable as PET imaging agents. We show the utility of the 64Cu-liposomes for quantitative in vivo imaging of healthy and tumor-bearing mice using PET. This remote loading method is a powerful tool for characterizing the in vivo performance of liposome based nanomedicine, and has great potential...

  15. Nanogels as imaging agents for modalities spanning the electromagnetic spectrum.

    Chan, Minnie; Almutairi, Adah

    2016-01-21

    In the past few decades, advances in imaging equipment and protocols have expanded the role of imaging in in vivo diagnosis and disease management, especially in cancer. Traditional imaging agents have rapid clearance and low specificity for disease detection. To improve accuracy in disease identification, localization and assessment, novel nanomaterials are frequently explored as imaging agents to achieve high detection specificity and sensitivity. A promising material for this purpose are hydrogel nanoparticles, whose high hydrophilicity, biocompatibility, and tunable size in the nanometer range make them ideal for imaging. These nanogels (10 to 200 nm) can circumvent uptake by the reticuloendothelial system, allowing longer circulation times than small molecules. In addition, their size/surface properties can be further tailored to optimize their pharmacokinetics for imaging of a particular disease. Herein, we provide a comprehensive review of nanogels as imaging agents in various modalities with sources of signal spanning the electromagnetic spectrum, including MRI, NIR, UV-vis, and PET. Many materials and formulation methods will be reviewed to highlight the versatility of nanogels as imaging agents.

  16. Advanced Contrast Agents for Multimodal Biomedical Imaging Based on Nanotechnology.

    Calle, Daniel; Ballesteros, Paloma; Cerdán, Sebastián

    2018-01-01

    Clinical imaging modalities have reached a prominent role in medical diagnosis and patient management in the last decades. Different image methodologies as Positron Emission Tomography, Single Photon Emission Tomography, X-Rays, or Magnetic Resonance Imaging are in continuous evolution to satisfy the increasing demands of current medical diagnosis. Progress in these methodologies has been favored by the parallel development of increasingly more powerful contrast agents. These are molecules that enhance the intrinsic contrast of the images in the tissues where they accumulate, revealing noninvasively the presence of characteristic molecular targets or differential physiopathological microenvironments. The contrast agent field is currently moving to improve the performance of these molecules by incorporating the advantages that modern nanotechnology offers. These include, mainly, the possibilities to combine imaging and therapeutic capabilities over the same theranostic platform or improve the targeting efficiency in vivo by molecular engineering of the nanostructures. In this review, we provide an introduction to multimodal imaging methods in biomedicine, the sub-nanometric imaging agents previously used and the development of advanced multimodal and theranostic imaging agents based in nanotechnology. We conclude providing some illustrative examples from our own laboratories, including recent progress in theranostic formulations of magnetoliposomes containing ω-3 poly-unsaturated fatty acids to treat inflammatory diseases, or the use of stealth liposomes engineered with a pH-sensitive nanovalve to release their cargo specifically in the acidic extracellular pH microenvironment of tumors.

  17. Benzimidazolyl methyliminodiacetic acids: new bifunctional chelators of technetium for hepatobiliary scintigraphy

    Hunt, F.C.; Wilson, J.G.; Maddalena, D.J.

    1979-01-01

    Dimethyl- and chloro- substituted benzimidazolyl methyliminodiacetic acids have been synthesized and evaluated as new bifunctional chelators of /sup 99m/Tc. Stannous chelates of these compounds were prepared as freeze-dried kits and labeled with /sup 99m/Tc. The radiopharmaceuticals thus prepared were rapidly excreted by the hepatobiliary system of rats and rabbits with little urinary excretion. The chloro- compound had a higher biliary and lesser urinary excretion than the dimethyl- however both technetium complexes provided good scintigraphic images of the hepatobiliary system in animals. The compounds behaved similarly to the /sup 99m/Tc-lidocaine iminodiacetic acid [HIDA] complexes with respect to their biliary elimination

  18. Factors predicting aggressiveness of non-hypervascular hepatic nodules detected on hepatobiliary phase of gadolinium ethoxybenzyl diethylene-triamine-pentaacetic-acid magnetic resonance imaging.

    Kanefuji, Tsutomu; Takano, Toru; Suda, Takeshi; Akazawa, Kouhei; Yokoo, Takeshi; Kamimura, Hiroteru; Kamimura, Kenya; Tsuchiya, Atsunori; Takamura, Masaaki; Kawai, Hirokazu; Yamagiwa, Satoshi; Aoyama, Hidefumi; Nomoto, Minoru; Terai, Shuji

    2015-04-21

    To establish a prognostic formula that distinguishes non-hypervascular hepatic nodules (NHNs) with higher aggressiveness from less hazardous one. Seventy-three NHNs were detected in gadolinium ethoxybenzyl diethylene-triamine-pentaacetic-acid magnetic resonance imaging (Gd-EOB-DTPA-MRI) study and confirmed to change 2 mm or more in size and/or to gain hypervascularity. All images were interpreted independently by an experienced, board-certified abdominal radiologist and hepatologist; both knew that the patients were at risk for hepatocellular carcinoma development but were blinded to the clinical information. A formula predicting NHN destiny was developed using a generalized estimating equation model with thirteen explanatory variables: age, gender, background liver diseases, Child-Pugh class, NHN diameter, T1-weighted imaging/T2-weighted imaging detectability, fat deposition, lower signal intensity in arterial phase, lower signal intensity in equilibrium phase, α-fetoprotein, des-γ-carboxy prothrombin, α-fetoprotein-L3, and coexistence of classical hepatocellular carcinoma. The accuracy of the formula was validated in bootstrap samples that were created by resampling of 1000 iterations. During a median follow-up period of 504 d, 73 NHNs with a median diameter of 9 mm (interquartile range: 8-12 mm) grew or shrank by 68.5% (fifty nodules) or 20.5% (fifteen nodules), respectively, whereas hypervascularity developed in 38.4% (twenty eight nodules). In the fifteen shrank nodules, twelve nodules disappeared, while 11.0% (eight nodules) were stable in size but acquired vascularity. A generalized estimating equation analysis selected five explanatories from the thirteen variables as significant factors to predict NHN progression. The estimated regression coefficients were 0.36 for age, 6.51 for lower signal intensity in arterial phase, 8.70 or 6.03 for positivity of hepatitis B virus or hepatitis C virus, 9.37 for des-γ-carboxy prothrombin, and -4.05 for fat

  19. The value of paradoxical uptake of hepatocellular carcinoma on the hepatobiliary phase of gadoxetic acid-enhanced liver magnetic resonance imaging for the prediction of lipiodol uptake after transcatheter arterial chemoembolization

    Kim, Jeong Woo, E-mail: pridebio@naver.com [Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Lee, Chang Hee, E-mail: chlee86@korea.ac.kr [Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Park, Yang Shin, E-mail: pys797979@naver.com [Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Seo, Tae Seok, E-mail: g1q1papa@korea.ac.kr [Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Song, Myung Gyu, E-mail: acube808@naver.com [Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Ji Hoon, E-mail: kjhhepar@naver.com [Department of Internal Medicine, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Kyeong Ah, E-mail: kahkim@korea.ac.kr [Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Park, Cheol Min, E-mail: radpic@hanmail.net [Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Highlights: • HCC{sub para} shows more frequent initial compact lipiodol uptake after TACE than HCC{sub def}. • HCC{sub para} demonstrates less frequent early local recurrence after TACE. • HCC{sub para} has larger mean size, lower AER, and more frequent capsule appearance. - Abstract: Purpose: To compare the response to transcatheter arterial chemoembolization (TACE) between hepatocellular carcinoma (HCC) with paradoxical uptake on the hepatobiliary phase (HBP) (HCC{sub para}) and HCC with defect on the HBP (HCC{sub def}), and to identify some imaging features that can differentiate between two groups. Materials and methods: Ninety-three HCCs from 54 patients who underwent gadoxetic acid-enhanced liver magnetic resonance imaging (MRI) prior to TACE were included. HCCs were classified into two groups according to the signal intensity (SI) on the HBP: HCC{sub para} and HCC{sub def}. Using post-TACE computed tomography (CT) as a reference standard, initial compact lipiodol uptake was assessed and compared between groups. The arterial enhancement ratio (AER), SI ratios of the arterial phase and HBP, and presence of the capsule appearance were compared between groups. After initial response, local tumor recurrence within 6 and 18 months was evaluated based on follow-up CT or MRI. Results: Fifteen HCC{sub para} and 78 HCC{sub def} were included. Compared to HCC{sub def}, HCC{sub para} showed more frequent initial compact lipiodol uptake (p = 0.009), larger mean size (p = 0.019), lower AER (p = 0.005), higher SI ratio of the HBP (p < 0.0001), and more frequent capsule appearance (p < 0.0001). Local tumor recurrence rate within 6 months was also significantly lower in HCC{sub para} than in HCC{sub def} (p = 0.008). Conclusion: Despite larger size and lower AER, HCC{sub para} showed more frequent initial compact lipiodol uptake and lower early local recurrence rate after TACE than did HCC{sub def}.

  20. Photoacoustic imaging at 1064nm wavelength with exogenous contrast agents

    Upputuri, Paul Kumar; Jiang, Yuyan; Pu, Kanyi; Pramanik, Manojit

    2018-02-01

    Photoacoustic (PA) imaging is a promising imaging modality for both preclinical research and clinical practices. Laser wavelengths in the first near infrared window (NIR-I, 650-950 nm) have been widely used for photoacoustic imaging. As compared with NIR-I window, scattering of photons by biological tissues is largely reduced in the second NIR (NIR-II) window, leading to enhanced imaging fidelity. However, the lack of biocompatible NIR-II absorbing exogenous agents prevented the use of this window for in vivo imaging. In recent years, few studies have been reported on photoacoustic imaging in NIR-II window using exogenous contrast agents. In this work, we discuss the recent work on PA imaging using 1064 nm wavelength, the fundamental of Nd:YAG laser, as an excitation wavelength. The PA imaging at 1064 nm is advantageous because of the low and homogeneous signal from tissue background, enabling high contrast in PA imaging when NIR-II absorbing contrast agents are employed.

  1. Hepato-biliary scintigraphy and hepatography with Tc-99m diethyl-acetanilido-iminodiacetate in obstructive jaundice

    Nielsen, S.P.; Trap-Jensen, J.; Lindenberg, J.; Nielsen, M.L.

    1978-01-01

    Tc-99m diethyl-IDA was used for combined serial hepato-biliary scintigraphy and processing of hepatographic curves, using a scintillation camera and an image-processing system. Patients with obstruction of the common bile duct, proven by operation, were investigated. Hepatograms from an area of interest corresponding to the periphery of the right liver lobe varied predictably with changes in the serum levels of alkaline phosphatase and bilirubin. Both anatomical and functional information was obtained. The investigation could be carried out even under reduced liver function. Hepatic uptake of the agent was noted at serum alkaline phosphatase levels up to 1000 U/l and serum bilirubin levels up to 170 μmol/l

  2. Dynamic hepatobiliary scintigraphy using EHIDA and HIDA

    Radtke, J.

    1980-01-01

    Data of 9 healthy test persons studied on an empty stomach using EHIDA and HIDA were analyzed in order to determine the influence of a region of interest on the shape of heart and liver function curves. The kinetics of EHIDA and HIDA in these 9 test persons showed marked differences in the passage of the hepatobiliary system and in plasma kinetics but not in renal urinary excretion. Further, functional histograms of the heart, liver, gall bladder, and duodenum of 25 healthy patients were established after meals and administration of EHIDA or HIDA. The parameters derived from these functional histograms did not differ significantly from the data of the test persons examined on an empty stomach. Also, the time interval since the last meal was found to be negligible. In 3 healthy test persons, the injected concentration of the radiopharmaceutical was increased to 8 times the standard dose. There was no significant change in HIDA kinetics except for a more rapid excretion into the intestine. In 7 healthy test persons, a comparative study was carried out of HIDA kinetics with and without decholine premedication. The normal collectives were compared with 118 patients with different morphological and functional findings. However, this method was not superior to sequential scintiscanning. Differential diagnosis of parenchymal and obstructive jaundice using the liver function curve is possible only in the acute stage in consideration of the analogue scintiscanning images. The data of the 9 healthy test persons were also used to assess the usefulness of EDP in eliminating statistical variations of the functional curves and in determining descriptive parameters. Curve smoothing by data bounding resulted in reproducible values, and the systematic error introduced by estination was avoided. (orig./MG) [de

  3. The clinical use of contrast agents in magnetic resonance imaging

    Bydder, G.M.

    1987-01-01

    Interest in the use of external agents to increase tissue contrasts has come from many sources dating back to the earliest work in NMR, to animal studies and to the widespread use of contrast agents in conventional radiological practice. The first clinical magnetic resonance images were published in 1980 and in the following year a brief account of the use of the paramagnetic agents in human volunteers was established. It was apparent relatively early in the development of magnetic resonance imaging (MRI) that a high level of soft tissue contrast was available de novo and the need for externally administered agents might therefore be small. This observation was tempered by the fact that separation of tumour from oedema was frequently better with contrast enhanced CT X-ray than with unenhanced MRI and that of a contrast agent might therefore be needed for MRI. At the end of 1983 the first parenteral agent gadoliminum diethylene triamine pentaacetic acid (Gd-DTPA) was used in volunteers and clinical studies began in 1984. At the present time only molecular O/sub 2/, oral iron compounds and Gd-DTPA are in clinical use although there are a number of other agents which have been used in animals and some of these may become available for clinical use in the foreseeable future

  4. Fluorescence Imaging/Agents in Tumor Resection.

    Stummer, Walter; Suero Molina, Eric

    2017-10-01

    Intraoperative fluorescence imaging allows real-time identification of diseased tissue during surgery without being influenced by brain shift and surgery interruption. 5-Aminolevulinic acid, useful for malignant gliomas and other tumors, is the most broadly explored compound approved for fluorescence-guided resection. Intravenous fluorescein sodium has recently received attention, highlighting tumor tissue based on extravasation at the blood-brain barrier (defective in many brain tumors). Fluorescein in perfused brain, unselective extravasation in brain perturbed by surgery, and propagation with edema are concerns. Fluorescein is not approved but targeted fluorochromes with affinity to brain tumor cells, in development, may offer future advantages. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Viscous optical clearing agent for in vivo optical imaging

    Deng, Zijian; Jing, Lijia; Wu, Ning; lv, Pengyu; Jiang, Xiaoyun; Ren, Qiushi; Li, Changhui

    2014-07-01

    By allowing more photons to reach deeper tissue, the optical clearing agent (OCA) has gained increasing attention in various optical imaging modalities. However, commonly used OCAs have high fluidity, limiting their applications in in vivo studies with oblique, uneven, or moving surfaces. In this work, we reported an OCA with high viscosity. We measured the properties of this viscous OCA, and tested its successful performances in the imaging of a living animal's skin with two optical imaging modalities: photoacoustic microscopy and optical coherence tomography. Our results demonstrated that the viscous OCA has a great potential in the study of different turbid tissues using various optical imaging modalities.

  6. The transport, hepatobiliary distribution and clearance of sup(99m)Tc-Sn-lidocaine iminodiacetic acid, sup(99m)Tc-Sn-Lida

    Noronha, O.P.D.; Sewatkar, A.B.; Ganatra, R.D.; Subramanian, G.

    1977-01-01

    Details are given of the preparation of stable sterile solutions of the radiopharmaceutical sup(99m)Tc-Sn-LIDA for use as a hepatobiliary scanning agent. Toxicity and survival studies in mice showed no untoward response even at a concentration of up to 210 mg/kg mouse, and the usual human dose is very much less than this. Tissue distribution studies in rats and mice showed a rapid decrease in liver activity with concomitant increase in gut activity. Scintiscans of a rabbit injected (i.v.) with 2.0 mCi of sup(99m)Tc-Sn-LIDA also showed extremely rapid excretion of the radiopharmaceutical. Sequential gamma camera images obtained 2 to 60 min after administration to overnight fasting normal human subjects revealed rapid liver uptake and gall bladder localization in about 20 min, followed by a gradual decrease in liver activity and increase in the activity in the intestinal tract. After about 40 min the liver has been washed-out of activity, leaving the gall bladder visible. sup(99m)Tc-Sn-LIDA is therefore an excellent hepatobiliary scanning agent. (U.K.)

  7. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-01-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function

  8. A comparison of positron-emitting blood pool imaging agents

    Hnatowich, D.J.; Kulprathipanja, S.; Evans, G.; Elmaleh, D.

    1979-01-01

    The three agents, 11 C-carboxyhaemoglobin, 68 Ga-transferrin and 68 Ga-labelled red cells have been compared in dogs to assess their relative merits for blood-pool imaging. For 1 h following administration of each agent, periodic blood samples were withdrawn for counting in a NaI (Tl) well counter while conventional two-dimensional images were obtained simultaneously on the Massachusetts General Hospital positron camera. Count rates in regions about the heart, liver and spleen were obtained for each image. The disappearance of blood activity as shown from the results of counting the blood samples and from the counting rates in regions about the heart was found to be identical within experimental error for the three agents. In the liver and spleen regions, the highest count rates were obtained with 68 Ga-transferrin and the lowest with 68 Ga-labelled red cells; count rates in these regions with labelled red cells were virtually constant throughout the 1 h study. It may be concluded that with the exceptions noted above, the three agents are approximately equivalent for blood-pool imaging. (author)

  9. Dynamic fluorescence imaging with molecular agents for cancer detection

    Kwon, Sun Kuk

    Non-invasive dynamic optical imaging of small animals requires the development of a novel fluorescence imaging modality. Herein, fluorescence imaging is demonstrated with sub-second camera integration times using agents specifically targeted to disease markers, enabling rapid detection of cancerous regions. The continuous-wave fluorescence imaging acquires data with an intensified or an electron-multiplying charge-coupled device. The work presented in this dissertation (i) assessed dose-dependent uptake using dynamic fluorescence imaging and pharmacokinetic (PK) models, (ii) evaluated disease marker availability in two different xenograft tumors, (iii) compared the impact of autofluorescence in fluorescence imaging of near-infrared (NIR) vs. red light excitable fluorescent contrast agents, (iv) demonstrated dual-wavelength fluorescence imaging of angiogenic vessels and lymphatics associated with a xenograft tumor model, and (v) examined dynamic multi-wavelength, whole-body fluorescence imaging with two different fluorescent contrast agents. PK analysis showed that the uptake of Cy5.5-c(KRGDf) in xenograft tumor regions linearly increased with doses of Cy5.5-c(KRGDf) up to 1.5 nmol/mouse. Above 1.5 nmol/mouse, the uptake did not increase with doses, suggesting receptor saturation. Target to background ratio (TBR) and PK analysis for two different tumor cell lines showed that while Kaposi's sarcoma (KS1767) exhibited early and rapid uptake of Cy5.5-c(KRGDf), human melanoma tumors (M21) had non-significant TBR differences and early uptake rates similar to the contralateral normal tissue regions. The differences may be due to different compartment location of the target. A comparison of fluorescence imaging with NIR vs. red light excitable fluorescent dyes demonstrates that NIR dyes are associated with less background signal, enabling rapid tumor detection. In contrast, animals injected with red light excitable fluorescent dyes showed high autofluorescence. Dual

  10. Technetium SPECT agents for imaging heart and brain

    Linder, K.E.

    1990-01-01

    One major goal of radiopharmaceutical research has been the development of technetium-based perfusion tracers for SPECT imaging of the heart and brain. The recent clinical introduction of the technetium complexes HM-PAO, ECD and DMG-2MP for brain imaging, and of CDO-MEB and MIBI for heart imaging promises to revolutionize the field of nuclear medicine. All of these agents appear to localize in the target tissue in proportion to blood flow, but their mechanisms of localization and/or retention may differ quite widely. In this talk, a survey of the new technetium SPECT agents will be presented. The inorganic and biological chemistry of these complexes, mechanisms of uptake and retention, QSAR studies, and potential clinical applications are discussed

  11. Paramagnetic metal complexes as potential relaxation agents for NMR imaging

    Coroiu, Ilioara; Demco, D. E.; Darabont, Al.; Bogdan, M.

    1997-01-01

    The development of nuclear magnetic resonance (NMR) imaging technique as a clinical diagnostic modality has prompted the need for a new class of pharmaceuticals. These drugs must be administered to a patient in order to enhance the image contrast between the normal and diseased tissue and/or indicate the status of organ function or blood flow. Paramagnetic compounds are presently undergoing extensive evaluation as contrast agents in magnetic resonance imaging (MRI). These agents increase contrast in MRI by differentially localizing in tissue where they increase the relaxation rates of nearby water protons. The longitudinal R 1 and transverse R 2 relaxivities were measured as a function of molar concentrations for some new paramagnetic complexes like the following: dysprosium, erbium and gadolinium citrates, gadolinium methylene diphosphonate, dysprosium and gadolinium iminodiacetate, manganese para-aminobenzoate and copper nicotinate. The available theoretical approaches for quantitative understanding are presented. (authors)

  12. Hepatobiliary Disorders in Celiac Disease: An Update

    Kaushal K. Prasad

    2011-01-01

    Full Text Available This communication reviews recent literature and summarizes hepatobiliary abnormalities that may complicate the clinical course of celiac disease. A wide spectrum of hepatobiliary diseases has been described, including asymptomatic elevations of liver enzyme levels, nonspecific hepatitis, nonalcoholic fatty liver disease, and autoimmune and cholestatic liver disease. Moreover, in the majority of patients, liver enzyme levels will normalize on a gluten-free diet. In addition, celiac disease may be associated with rare hepatic complications, such as hepatic T-cell lymphoma. Because many celiac patients do not have overt gastrointestinal symptoms, a high index of suspicion is required. Simple methods of detecting celiac disease such as serum antibody tests help in the early identification of the disease, thus preventing serious complications of the disorder. The IgG DGP antibody test and IgA tTG antibody test used in combination are an excellent screening test for suspected cases of celiac disease.

  13. Cellular image segmentation using n-agent cooperative game theory

    Dimock, Ian B.; Wan, Justin W. L.

    2016-03-01

    Image segmentation is an important problem in computer vision and has significant applications in the segmentation of cellular images. Many different imaging techniques exist and produce a variety of image properties which pose difficulties to image segmentation routines. Bright-field images are particularly challenging because of the non-uniform shape of the cells, the low contrast between cells and background, and imaging artifacts such as halos and broken edges. Classical segmentation techniques often produce poor results on these challenging images. Previous attempts at bright-field imaging are often limited in scope to the images that they segment. In this paper, we introduce a new algorithm for automatically segmenting cellular images. The algorithm incorporates two game theoretic models which allow each pixel to act as an independent agent with the goal of selecting their best labelling strategy. In the non-cooperative model, the pixels choose strategies greedily based only on local information. In the cooperative model, the pixels can form coalitions, which select labelling strategies that benefit the entire group. Combining these two models produces a method which allows the pixels to balance both local and global information when selecting their label. With the addition of k-means and active contour techniques for initialization and post-processing purposes, we achieve a robust segmentation routine. The algorithm is applied to several cell image datasets including bright-field images, fluorescent images and simulated images. Experiments show that the algorithm produces good segmentation results across the variety of datasets which differ in cell density, cell shape, contrast, and noise levels.

  14. Hepatobiliary scintigraphy in patients with bile leaks

    Carichner, S.L.; Nagle, C.E.

    1987-01-01

    Hepatobiliary scintigraphy has been recognized as a useful tool in detecting the presence and sites of bile leaks. The clinical settings in which bile leaks are likely to occur, as well as some of the scintigraphic patterns seen in patients with bile leaks, are reviewed here. Tips for technologists are offered on interventions that might enhanced the quality of information available to the nuclear physician

  15. Magnetic nanoparticles as contrast agents for molecular imaging in medicine

    O'Donnell, Matthew

    2018-05-01

    For over twenty years, superparamagnetic nanoparticles have been developed for a number of medical applications ranging from bioseparations, magnetic drug targeting, hyperthermia and imaging. Recent studies have shown that they can be functionalized for in vivo biological targeting, potentially enabling nanoagents for molecular imaging and site-localized drug delivery. Here we review several imaging technologies developed using functionalized superparamagnetic iron oxide nanoparticles (SPIONs) as targeted molecular agents. Several imaging modalities have exploited the large induced magnetic moment of SPIONs to create local mechanical force. Magnetic force microscopy can probe nanoparticle uptake in single cells. For in vivo applications, magnetomotive modulation of primary images in ultrasound (US), photoacoustics (PA), and optical coherence tomography (OCT) can help identify very small concentrations of nanoagents while simultaneously suppressing intrinsic background signals from tissue.

  16. Utility of morphine-augmented hepatobiliary scanning in evaluation of acute cholecystitis

    Kistler, A.M.; Ziessman, H.A.; Gooch, D.; Bitterman, P.

    1989-01-01

    The authors review experience with morphine sulfate-augmented cholescintigraphy in suspected acute cholecystitis. MS has been recommended to reduce study time while maintaining accuracy of hepatobiliary scans. Patients received 5-mCi injections of Tc-99m mebrofenin and imaged on a low-field-view gamma camera. In 32 patients with nonvisualization of the gallbladder at 30-40 minutes after injection, 2 mg MS was given intravenously, and imaging continued for an additional 30 minutes

  17. Troubleshooting arterial-phase MR images of gadoxetate disodium-enhanced liver

    Huh, Ji Mi; Kim, So Yeon; Lee, Seung Soo; Kim, Kyoung Won [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yeh, Benjamin M.; Wang, Z. Jane [Dept. of Radiologyand Biomedical Imaging, University of California San Francisco, San Francisco (United States); Wu, En Haw [Dept. of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou and Chang Gung University College of Medicine, Taoyuan (China); Zhao, Li Qin [Beijing Friendship Hospital, Capital Medical University, Beijing (China); Chang, Wei Chou [Tri-Service General Hospital and National Defense Medical Center, Taipei (China)

    2015-12-15

    Gadoxetate disodium is a widely used magnetic resonance (MR) contrast agent for liver MR imaging, and it provides both dynamic and hepatobiliary phase images. However, acquiring optimal arterial phase images at liver MR using gadoxetate disodium is more challenging than using conventional extracellular MR contrast agent because of the small volume administered, the gadolinium content of the agent, and the common occurrence of transient severe motion. In this article, we identify the challenges in obtaining high-quality arterial-phase images of gadoxetate disodium-enhanced liver MR imaging and present strategies for optimizing arterial-phase imaging based on the thorough review of recent research in this field.

  18. Troubleshooting arterial-phase MR images of gadoxetate disodium-enhanced liver

    Huh, Ji Mi; Kim, So Yeon; Lee, Seung Soo; Kim, Kyoung Won; Yeh, Benjamin M.; Wang, Z. Jane; Wu, En Haw; Zhao, Li Qin; Chang, Wei Chou

    2015-01-01

    Gadoxetate disodium is a widely used magnetic resonance (MR) contrast agent for liver MR imaging, and it provides both dynamic and hepatobiliary phase images. However, acquiring optimal arterial phase images at liver MR using gadoxetate disodium is more challenging than using conventional extracellular MR contrast agent because of the small volume administered, the gadolinium content of the agent, and the common occurrence of transient severe motion. In this article, we identify the challenges in obtaining high-quality arterial-phase images of gadoxetate disodium-enhanced liver MR imaging and present strategies for optimizing arterial-phase imaging based on the thorough review of recent research in this field

  19. Microscopic validation of whole mouse micro-metastatic tumor imaging agents using cryo-imaging and sliding organ image registration

    Liu, Yiqiao; Zhou, Bo; Qutaish, Mohammed; Wilson, David L.

    2016-01-01

    We created a metastasis imaging, analysis platform consisting of software and multi-spectral cryo-imaging system suitable for evaluating emerging imaging agents targeting micro-metastatic tumor. We analyzed CREKA-Gd in MRI, followed by cryo-imaging which repeatedly sectioned and tiled microscope images of the tissue block face, providing anatomical bright field and molecular fluorescence, enabling 3D microscopic imaging of the entire mouse with single metastatic cell sensitivity. To register ...

  20. Development of (F-18)-Labeled Amyloid Imaging Agents for PET

    Mathis, C.A.

    2007-01-01

    The applicant proposes to design and synthesize a series of fluorine-18-labeled radiopharmaceuticals to be used as amyloid imaging agents for positron emission tomography (PET). The investigators will conduct comprehensive iterative in vitro and in vivo studies based upon well defined acceptance criteria in order to identify lead agents suitable for human studies. The long term goals are to apply the selected radiotracers as potential diagnostic agents of Alzheimer's disease (AD), as surrogate markers of amyloid in the brain to determine the efficacy of anti-amyloid therapeutic drugs, and as tools to help address basic scientific questions regarding the progression of the neuropathology of AD, such as testing the 'amyloid cascade hypothesis' which holds that amyloid accumulation is the primary cause of AD.

  1. In vivo imaging agents: an international market report

    1990-01-01

    The purpose of this study is to provide a global perspective of the in vivo imaging agents business to market planning executives who are working for companies that develop, produce and distribute various types of in vivo imaging agents. Others that could find this study useful include investment bankers, regulatory and governmental authorities and purchasers of these products. The study attempts to diligently provide market data by type for important geographic markets - Western Europe, the U.S.A., and Japan. A competitive intelligence section which discusses companies involved in these markets constitutes the last part of this study. These profiles are not intended to extensively evaluate each company's marketing strengths or strategies but to provide a general idea of the market presence and prospects. A combination of primary and secondary research is used for all findings. (author)

  2. Basic and clinical studies on hepatobiliary function test with sup(99m)Tc-PI

    Narabayashi, Isamu; Shigemoto, Hirosada; Ito, Yasuhiko; Muranaka, Akira; Ohtsuka, Nobuaki

    1979-01-01

    In these basic and clinical studies, the usefulness of sup(99m)Tc-pyridoxilideneisoleucine, a new hepatobiliary agent, was evaluated for a hepatobiliary function test in comparison with sup(99m)Tc-N-[N-(2,6 dimethylphenyl)carbamoylmethyl] iminodiacetic acid (HIDA) and 131 I-rose bengal (RB). The experiments were performed with 2.5 - 5 kg rabbits. Hepatic uptake and the excretion of sup(99m)Tc-pyridoxylidene isoleucine (PI) were earlier than those of 131 I-RB. However, biliary excretions of sup(99m)Tc-PI and sup(99m)Tc-HIDA were less than that of 131 I-RB, because urinary excretions of sup(99m)Tc-labeled compounds were greater. During the first 2.5 - 5 min, sup(99m)Tc-labeled agents had lower blood levels than 131 I-RB. At 6 days after the choledochal ligation, no hepatic uptake of sup(99m)Tc-PI was noted, although 131 I-RB concentrated to the liver. Blood retention of sup(99m)Tc-PI might not always reflect hepatobiliary function, especially in the hyperbilirubinemia. On the other hand, hepatograms from a region of interest corresponding to the liver varied with changes in the serum bilirubin level, although no hepatic uptake was detected in the complete obstructive jaundice and severe parenchymal liver disease being over 7 mg/dl in the serum bilirubin level. (author)

  3. Novel MR imaging contrast agents for cancer detection

    Daryoush Shahbazi-Gahrouei

    2009-05-01

    Full Text Available

    • BACKGROUND: Novel potential MR imaging contrast agents Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP, Gd-hematoporphyrin (Gd-H, Gd-DTPA-9.2.27 against melanoma, Gd-DTPA-WM53 against leukemia and Gd-DTPAC595 against breast cancer cells were synthesized and applied to mice with different human cancer cells (melanoma MM-138, leukemia HL-60, breast MCF-7. The relaxivity, the biodistribution, T1 relaxation times, and signal enhancement of the contrast agents are presented and the results are compared.
    • METHODS: After preparation of contrast agents, the animal studies were performed. The cells (2×106 cells were injected subcutaneously in the both flanks of mice. Two to three weeks after tumor plantation, when the tumor diameter was 2-4 mm, mice were injected with the different contrast agents. The animals were sacrificed at 24 hr post IP injection followed by removal of critical organs. The T1 relaxation times and signal intensities of samples were measured using 11.4 T magnetic field and Gd concentration were measured using UV-spectrophotometer.
    • RESULTS: For Gd-H, the percent of Gd localized to the tumors measured by UV-spect was 28, 23 and 21 in leukemia, melanoma and breast cells, respectively. For Gd-TCP this amount was 21%, 18% and 15%, respectively. For Gd-DTPA-9.2.27, Gd-DTPA-WM53 and Gd-DTPA-C595 approximately 35%, 32% and 27% of gadolinium localized to their specific tumor, respectively.
    • CONCLUSION: The specific studied conjugates showed good tumor uptake in the relevant cell lines and low levels of Gd in the liver, kidney and spleen. The studied agents have considerable promise for further diagnosis applications of MR imaging.
    • KEYWORDS: Magnetic Resonance, Imaging, Monoclonal Antibody, Contrast Agents, Gadolinium, Early Detection of Cancer.

  4. Quinone-fused porphyrins as contrast agents for photoacoustic imaging

    Banala, Srinivas

    2017-06-27

    Photoacoustic (PA) imaging is an emerging non-invasive diagnostic modality with many potential clinical applications in oncology, rheumatology and the cardiovascular field. For this purpose, there is a high demand for exogenous contrast agents with high absorption coefficients in the optical window for tissue imaging, i.e. the near infrared (NIR) range between 680 and 950 nm. We herein report the photoacoustic properties of quinone-fused porphyrins inserted with different transition metals as new highly promising candidates. These dyes exhibit intense NIR absorption, a lack of fluorescence emission, and PA sensitivity in concentrations below 3 nmol mL. In this context, the highest PA signal was obtained with a Zn(ii) inserted dye. Furthermore, this dye was stable in blood serum and free thiol solution and exhibited negligible cell toxicity. Additionally, the Zn(ii) probe could be detected with an up to 3.2 fold higher PA intensity compared to the clinically most commonly used PA agent, ICG. Thus, further exploration of the \\'quinone-fusing\\' approach to other chromophores may be an efficient way to generate highly potent PA agents that do not fluoresce and shift their absorption into the NIR range.

  5. Diagnosis of acute cholecystitis using hepatobiliary scan with technetium-99m PIPIDA

    Bennett, M.T.; Sheldon, M.I.; dos Remedios, L.V.; Weber, P.M.

    1981-01-01

    Sixty patients were evaluated for acute abdominal pain using technetium-99m PIPIDA hepatobiliary imaging. The sensitivity of the test was 90.6 percent in all patients and the accuracy was 93.3 percent. In the evaluation of acutely ill patients with right upper quadrant pain, fever, nausea and vomiting, hepatobiliary imaging with PIPIDA is the preferred test for diagnosing acute cholecystitis. If the test is positive, disease of the gallbladder and probably acute cholecystitis are present. Early operation can proceed if desirable. If the test is negative and the bilirubin level is less than 5.0 mg/dl, acute cholecystitis is not present. In such cases conservative treatment is appropriate, and follow-up tests should be performed to evaluate the possibility of chronic cholecystitis. When the bilirubin level exceeds 5.0 mg/dl, the test is often indeterminate

  6. Bile ascites in adults. Diagnosis using hepatobiliary scintigraphy and paracentesis

    Nagle, C.E.; Fink-Bennett, D.; Freitas, J.E.

    1985-01-01

    Hepatobiliary scintigraphy has been recognized as a useful diagnostic tool in detecting the presence and site of bile leaks. The authors report a case of bile ascites secondary to a postsurgical biliary leak, the scintigraphic findings in bile ascites, and the potential use of paracentesis, in combination with hepatobiliary scintigraphy, in confirming the presence of bile ascites and a bile leak

  7. Application of I-123 HIPDM as a lung imaging agent

    Shih, W J; Coupal, J J; Dillon, M L; Kung, H F

    1988-04-01

    N,N,N'-Trimethyl-N'-(2-Hydroxyl-3-Methyl-5-/sup 123/I Iodobenzyl)-1,3-Propanediamine.Hcl (/sup 123/I-HIPDM) has been used for diagnosis of patients with strokes and demantias. Since this radiopharmaceutical is also accumulated in the lung, we routinely performed a lung image or images immediately prior to cerebral planar and SPECT images after a 3-5 mCi /sup 123/I-HIPDM injection. During the past 14 months, we obtained 78 (age from 41 to 92 years, average 66.7+-8.9 years; 64 males, 14 females) suspected stroke or dementia patients' lung images. All lung images were correlated to chest X-ray (CXR) or CT and other clinical data. Sixty five of 78 patients had normal lungs showing homogeneous distribution of activity throughout the lungs which correlated well to normal CXR and/or CT studies. Abnormal scintigraphic patterns of the 13 patients included lung defect (5 bronchogenic carcinoma with or without atelectasis) and decreased uptake in apices (8 chronic obstructive pulmonary disease). The findings of pulmonary intrathoracic pathologies on lung images with /sup 123/I-HIPDM suggests further evaluation of the agent for detection of localized pulmonary diseases and pulmonary physiological studies relating to amine metabolism.

  8. State and development of new clinical contrast agents for MR diagnosis of liver diseases

    Rummeny, E.J.; Peters, P.E.

    1992-01-01

    MR contrast agents are developed for pharmaceutical manipulation of tissue signal intensities. Today it is widely recognized that MR contrast agents will play an increasingly important role in MR imaging of the liver. Contrast-enhanced MR-imaging allows to obtain simultaneously dynamic physiologic information and high anatomci detail. Up to now three major classes of MR contrast agents are available for clinical MR-imaging of the liver. These include paramagnetic perfusion agents, hepatobiliary agents, and superparamagnetic RES-specific iron oxide particles. A fourth class of contrast agents now in use for animal experiments includes ultrasmall superparamagnetic particles which can be targeted to extrareticuloendothelial structures such as asialoglycoprotein receptors of hepatocytes. In this article, we review recent advances in the development of MR contrast media and the clinical of contrast-enhanced MR imaging of the liver. (orig.) [de

  9. AAZTA: an ideal chelating agent for the development of {sup 44}Sc PET imaging agents

    Nagy, Gabor; Szikra, Dezso; Trencsenyi, Gyoergy [Scanomed Ltd., Debrecen (Hungary); University of Debrecen, Medical Imaging Clinic (Hungary); Fekete, Aniko [University of Debrecen, Medical Imaging Clinic (Hungary); Garai, Ildiko [Scanomed Ltd., Debrecen (Hungary); Giani, Arianna M.; Negri, Roberto [Dipartimento di Scienze del Farmaco, Universita del Piemonte Orientale, Novara (Italy); Masciocchi, Norberto [Dipartimento di Scienza e Alta Tecnologia e To.Sca.Lab, Universita degli Studi dell' Insubria, Como (Italy); Maiocchi, Alessandro; Uggeri, Fulvio [Bracco Imaging spa, Bracco Research Centre, Colleretto Giacosa (Italy); Toth, Imre [Department of Inorganic and Analytical Chemistry, University of Debrecen (Hungary); Aime, Silvio [Dipartimento di Biotecnologie Molecolari e Scienze della Salute, Centro di Imaging Molecolare e Preclinico, Universita degli Studi di Torino (Italy); Giovenzana, Giovanni B. [Dipartimento di Scienze del Farmaco, Universita del Piemonte Orientale, Novara (Italy); CAGE Chemicals srl, Novara (Italy); Baranyai, Zsolt [Bracco Imaging spa, Bracco Research Centre, Colleretto Giacosa (Italy); Department of Inorganic and Analytical Chemistry, University of Debrecen (Hungary)

    2017-02-13

    Unprecedented fast and efficient complexation of Sc{sup III} was demonstrated with the chelating agent AAZTA (AAZTA=1,4-bis(carboxymethyl)-6-[bis(carboxymethyl)] amino-6-methylperhydro-1,4-d iazepine) under mild experimental conditions. The robustness of the {sup 44}Sc(AAZTA){sup -} chelate and conjugated biomolecules thereof is further shown by in vivo PET imaging in healthy and tumor mice models. The new results pave the way towards development of efficient Sc-based radiopharmaceuticals using the AAZTA chelator. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Potential Pitfalls on the (99m)Tc-Mebrofenin Hepatobiliary Scintigraphy in a Patient with Biliary Atresia Splenic Malformation Syndrome

    Maestri Brittain, Jane; Borgwardt, Lise

    2016-01-01

    the first years of life. Kasai portoenterostomy restores bile flow and delay the progressive liver damage thereby postponing liver transplantation. An early diagnosis is of most importance to ensure the effectiveness of the operation. The (99m)Tc-Mebrofenin hepatobiliary scintigraphy is part...... of BA. Laparotomy with antegrade cholangiography is then performed giving the final diagnosis when the remains of the obliterated biliary tree are revealed in the case of BA. We present a case demonstrating some of the challenges of interpreting the (99m)Tc-Mebrofenin hepatobiliary scintigraphy...... in an infant with BASM and stress the importance that the (99m)Tc-Mebrofenin hepatobiliary scintigraphy is part of a spectrum of imaging modalities in diagnosing BA....

  11. Gall blandder kinetics in diabetics. A hepatobiliary scintigraphy overview

    Shelley, S.; Indirani, M.; Gokhale, S.; Anirudhan, N.

    2004-01-01

    Introduction: Hepatobiliary scintigraphy is underutilized in the evaluation of Gall Bladder(GB) function in diabetics when compared to various other imaging modalities that are currently available.It establishes the function of GB in Diabetes mellitus noninvasively, with a quantified ejection fraction thereby helping to resolve the problem of diabetic cholecystopathy, in the evaluation of visceral neuropathy. Aim: To study Gall Bladder kinetics and emptying in diabetic patients. Materials and methods: One forty eight patients of both sexes in the age group of 30 to 70 were included in the study between 1997 to 1999 in our institution.A 90 minute dynamic post mebrofenin study was acquired. A fatty meal of 600 kcal was given to these patients once the Gall Bladder was visualized.Time activity curves were generated and the Gall Bladder contraction in these patients was evaluated.Patients were classified into 3 groups-Group 1 consists of established Diabetic patients. Group 2 consists of patients with impaired glucose tolerance. Group 3 consists of controls. Observation and result: In Group 1 (n=47) ,28 patients (60%) showed reduced ejection fraction and the mean EF% was 44.12 +/- 16.6. In Group 2 (n=48), 18 patients (38%) showed slightly reduced ejection fraction and the mean EF % was 51.56 +/- 15.67. In Group 3(n=53), 7 patients (13%) showed reduced ejection fraction and the meanEF % was 69.77 +/- 13.59. Test of significance was done using 'Z' test also called normal test in large samples. This study has shown that the average Ejection Fraction (in%) is maximum in normal group and least in diabetic group. Conclusion: Hepatobiliary scintigraphy is helpful in early identification of autonomic dysfunction of Gall Bladder in diabetic patients and in patients with impaired glucose tolerance. (authors)

  12. The use of contrast agent for imaging biological samples

    Dammer, J; Sopko, V; Jakubek, J [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Weyda, F, E-mail: jiri.dammer@utef.cvut.cz [Biological center of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2011-01-15

    The technique of X-ray transmission imaging has been available for over a century and is still among the fastest and easiest approaches to the studies of internal structure of biological samples. Recent advances in semiconductor technology have led to the development of new types of X-ray detectors with direct conversion of interacting X-ray photon to an electric signal. Semiconductor pixel detectors seem to be specially promising; compared to the film technique, they provide single-quantum and real-time digital information about the objects being studied. We describe the recently developed radiographic apparatus, equipped with Medipix2 semiconductor pixel detector. The detector is used as an imager that counts individual photons of ionizing radiation, emitted by an X-ray tube (micro- or nano-focus FeinFocus). Thanks to the wide dynamic range of the Medipix2 detector and its high spatial resolution better than 1{mu}m, the setup is particularly suitable for radiographic imaging of small biological samples, including in-vivo observations with contrast agent (Optiray). Along with the description of the apparatus we provide examples of the use iodine contrast agent as a tracer in various insects as model organisms. The motivation of our work is to develop our imaging techniques as non-destructive and non-invasive. Microradiographic imaging helps detect organisms living in a not visible environment, visualize the internal biological processes and also to resolve the details of their body (morphology). Tiny live insects are an ideal object for our studies.

  13. Liver nodules. MR imaging using extracellular gadolinium agent

    Yoshimitsu, Kengo; Honda, Hiroshi

    2009-01-01

    Extracellular gadolinium (Gd)-containing contrast medium, including gadopentetate dimeglumine (Gd-DTPA), has been playing a main role in the diagnostic MR imaging of the liver. Its significance is two-fold: assessment of the degree of neovascularity or angiogenesis in its early dynamic phase, and that of bulk of interstitium in its equilibrium phase. With the advent of gadolinium ethoxybenzyl diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA), which can be used as a dynamic study agent by bolus injection in addition to its original use as a tissue-specific agent, some possibility has been suggested that extracellular Gd agent would be no longer available in the near future in the field of liver MR imaging. Neovascularity or arterial supply of a lesion may well be assessed by Gd-EOB-DTPA, when carefully selected pulse sequence and well designed injection protocol are used, as well as by Gd-DTPA. However, the pertinent assessment of interstitium or stroma can never be achieved by Gd-EOB-DTPA or any other contrast medium present. The interstitium of neoplasm, typically called as stromal fibrosis, is generated through the interaction between the neoplasm per se and its host, and its clinicopathological significance related to disease prognosis has well been established in some disease entities. Extracellular Gd agent is the only contrast medium that can provide information regarding the tumor stroma in a simple, easy, safe and non-invasive fashion, when properly used. This review article discusses, dynamic MR imaging features of representative liver diseases, including several recent topics. From technical point of view, 3D gradient-echo sequence with fat suppression should be used for dynamic studies along with tailored injection protocol using autoinjector and saline flush. Vascularity of hepatocellular carcinoma (HCC) can now be properly assessed by dynamic MR with approximately 90% concordance with CT during hepatic arteriography. Portal phase images can be used to

  14. Magnetic susceptibility imaging with a nonionic contrast agent

    Cacheris, W.; Rocklage, S.M.; Quay, S.; Dow, W.; Love, D.; Worah, D.; Lim, K.

    1988-01-01

    The magnetic susceptibility mechanism for MR imaging contrast enhancement has the advantage of providing useful information, such as cerebral blood flow, without crossing the blood-brain barrier. In this paper the authors report the use of a highly effective, relatively nontoxic chelate as a magnetic susceptibility agent. Dy-DTPA-bis(methylamide) (Dy-DTPA-BMA) has an extremely low acute toxicity (LD-50, intravenous, mice ∼ 40 mmol/kg). Doses of 1 mmol/kg and 2 mmol/kg Dy-DTPA-BMA lowered the initial signal intensity 63% to 57%, respectively. The utility of this technique in detecting areas of reduced blood flow within the brain was demonstrated by imaging a rabbit with a cerebral perfusion deficit

  15. The preparation and characterization of peptide's lung cancer imaging agent

    Liu Jianfeng; Chu Liping; Wang Yan; Wang Yueying; Liu Jinjian; Wu Hongying

    2010-01-01

    Objective: To screen in vivo lung cancer specific binding seven peptides by T7 phage display peptide library, so as to prepare peptide's lung cancer early diagnostic agent. Methods: Use phage display in vivo technology, the 7-peptide phage that binding the lung cancer specifically was obtained, then the DNA sequence was measured and the seven peptide was synthesized. After labeled by 125 I, the seven peptide was injected into mice via vein and the distribution was observed. Results: One peptide was obtained by four rounds screening, and the peptide can bind lung cancer tissue specifically. Two hours after injection get the best imaging of lung cancer, metabolism of peptide in mice is fast, the distribution in vivo is decrease six hours and almost disappear 20 hours after injection. Conclusion: The peptide can image and diagnose lung cancer better. (authors)

  16. Hepatobiliary system functional analysis by blood flow and clearance delay model

    Aboltins, A.; Reinholds, E.

    2002-01-01

    A mathematical model for describing liver uptake-excretion is developed and approved. Model is based on different timing delays in hepatobiliary and blood flow system elements. Series of scintigraphic images with 99m Tc-mebrofenins or 99m Tc-HIDA taken with standard nuclear medicine gamma camera are used as the real data for calculations. The time-activity curves are obtained from many regions of human body - heart, liver, gallbladder, spleen, aorta, vein, etc. Both first pass and dynamic acquisition data are used. Results are calculated using real system parameters and compared to real scintigraphy data. Mathematical simulations are made to show difference of hepatobiliary system function at three main points: normal function, good blood flow with bad hepatic function and bad blood flow with good hepatic function. (authors)

  17. Nicotinic α4β2 receptor imaging agents

    Pichika, Rama; Easwaramoorthy, Balasubramaniam; Collins, Daphne; Christian, Bradley T.; Shi, Bingzhi; Narayanan, Tanjore K.; Potkin, Steven G.; Mukherjee, Jogeshwar

    2006-01-01

    The α4β2 nicotinic acetylcholine receptor (nAChR) has been implicated in various neurodegenerative diseases. Optimal positron emission tomography (PET) imaging agents are therefore highly desired for this receptor. We report here the development and initial evaluation of 2-fluoro-3-[2-((S)-3-pyrrolinyl)methoxy]pyridine (nifene). In vitro binding affinity of nifene in rat brain homogenate using 3 H-cytisine exhibited a K i =0.50 nM for the α4β2 sites. The radiosynthesis of 2- 18 F-fluoro-3-[2-((S)-3-pyrrolinyl)methoxy]pyridine ( 18 F-nifene) was accomplished in 2.5 h with an overall radiochemical yield of 40-50%, decay corrected. The specific activity was estimated to be approx. 37-185 GBq/μmol. In vitro autoradiography in rat brain slices indicated selective binding of 18 F-nifene to anteroventral thalamic (AVT) nucleus, thalamus, subiculum, striata, cortex and other regions consistent with α4β2 receptor distribution. Rat cerebellum showed some binding, whereas regions in the hippocampus had the lowest binding. The highest ratio of >13 between AVT and cerebellum was measured for 18 F-nifene in rat brain slices. The specific binding was reduced (>95%) by 300 μM nicotine in these brain regions. Positron emission tomography imaging study of 18 F-nifene (130 MBq) in anesthetized rhesus monkey was carried out using an ECAT EXACT HR+ scanner. PET study showed selective maximal uptake in the regions of the anterior medial thalamus, ventro-lateral thalamus, lateral geniculate, cingulate gyrus, temporal cortex including the subiculum. The cerebellum in the monkeys showed lower binding than the other regions. Thalamus-to-cerebellum ratio peaked at 30-35 min postinjection to a value of 2.2 and subsequently reduced. The faster binding profile of 18 F-nifene indicates promise as a PET imaging agent and thus needs further evaluation

  18. Shape Effects in Nanoparticle-Based Imaging Agents

    Culver, Kayla Shani Brook

    At the nanoscale, material properties become highly size and shape dependent. These properties can be manipulated and exploited for a variety of biomedical applications, including sensing, drug delivery, diagnostics, and imaging. In particular, nanoparticles of different materials, sizes and shapes have been developed as high-performance contrast agents for optical, electron, and medical imaging. In this thesis, I focus on gold nanoparticles because they are widely used as contrast agents in multiple types of imaging modalities. Additionally, the surface of gold can be readily functionalized with ligands and the structure of the particles can be manipulated to modulate their performance as imaging agents. The properties of nanoparticles can generate contrast directly. For example, the light scattering properties of gold particles can be visualized in optical microscopy, the high electron density of gold produces contrast in electron microscopy, and the x-ray absorption properties of gold can be detected in medical x-ray and computed tomography imaging. Alternatively, the properties of the nanomaterial can be exploited to modulate the signal produced by other molecules that are bound to the particle surface. The light emission of molecular fluorophores can be quenched or dramatically increased by coupling to the optical field enhancements of gold nanoparticles, and the performance of gadolinium (Gd(III))-based magnetic resonance imaging (MRI) contrast agents can be increased by coupling to the rotational motion of nanoparticles. In this dissertation, I focus specifically on how the structure of star-shaped gold particles (nanostars) can be exploited as single-particle optical probes and to dramatically enhance the relaxivity of Gd(III) bound to the surface. Differential interference contrast (DIC) is a type of wide-field diffraction-limited optical microscopy that is commonly used by biologists to image cells without labels. Here, I demonstrate the DIC can be used

  19. Gadolinium chloride as a contrast agent for imaging wood composite components by magnetic resonance

    Thomas L. Eberhardt; Chi-Leung So; Andrea Protti; Po-Wah So

    2009-01-01

    Although paramagnetic contrast agents have an established track record in medical uses of magnetic resonance imaging (MRI), only recently has a contrast agent been used for enhancing MRI images of solid wood specimens. Expanding on this concept, wood veneers were treated with a gadolinium-based contrast agent and used in a model system comprising three-ply plywood...

  20. Positrons as imaging agents and probes in nanotechnology

    Smith, Suzanne V

    2009-01-01

    Positron emission tomography (PET) tracks a positron emitting radiopharmaceutical injected into the body and generates a 3-dimensional image of its location. Introduced in the early 70s, it has now developed into a powerful medical diagnostic tool for routine clinical use as well as in drug development. Unrivalled as a highly sensitive, specific and non-invasive imaging tool, PET unfortunately lacks the resolution of Computer Tomography (CT) and Magnetic Resonance Imaging (MRI). As the resolution of PET depends significantly on the energy of the positron incorporated in the radiopharmaceutical and its interaction with its surrounding tissue, there is growing interest in expanding our understanding of how positrons interact at the atomic and molecular level. A better understanding of these interactions will contribute to improving the resolution of PET and assist in the design of better imaging agents. Positrons are also used in Positron Annihilation Lifetime Spectroscopy (PALS) to determine electron density and or presence and incidence of micro- and mesopores (0.1 to 10 nm) in materials. The control of porosity in engineered materials is crucial for applications such as controlled release or air and water resistant films. Equally important to the design of nano and microtechnologies, is our understanding of the microenvironments within these pores and on surfaces. Hence as radiopharmaceuticals are designed to track disease, nuclear probes (radioactive molecules) are synthesized to investigate the chemical properties within these pores. This article will give a brief overview of the present role of positrons in imaging as well as explore its potential to contribute in the engineering of new materials to the marketplace.

  1. Formulation of MIBI Kit as a heart imaging agent

    Widyastuti; A, Hanafiah; Yunilda; A, Laksmi; Setyowati, Sri; Y Veronika

    1999-01-01

    9 9 m Tc labelled 2-methoxy-isobutyl-isonitrile(MIBI) has been known as an imaging agent for myocardial perfusion. This radiopharmaceutical preparation gives the same satisfactory result as Thallium- 2 10TI, and presumably could replace 2 01TI because of same advantages. MIBI kit was formulated from MIBI ligand produced by RPC-BATAN which has been characterized and tested for quality. The formula used in this research referred to the formula of imported product(Cardiolite, MIBI kit produced by Dupont), and the quality control testing was performed by comparing some parameters to the imported product. The parameters used for QC testing were radiochemical purity, biodistribution in nice and heart imaging in human volunteer using gamma camera. The result of the experiment showed that the radiochemical purity was 95 % in average, biodistribution in heart to liver gave the ratio of 0.67, 1.5, and 2.53 respectively at 10, 30 and 60 minutes after injection. The result of clinical testing in some volunteers gave contrast images as good as given by Cardiolite. The optimum condition of freeze drying has been found, and the kit can be used for more than 6 months

  2. Characterization of nanoparticle-based contrast agents for molecular magnetic resonance imaging

    Shan, Liang; Chopra, Arvind; Leung, Kam; Eckelman, William C.; Menkens, Anne E.

    2012-01-01

    The development of molecular imaging agents is currently undergoing a dramatic expansion. As of October 2011, ∼4,800 newly developed agents have been synthesized and characterized in vitro and in animal models of human disease. Despite this rapid progress, the transfer of these agents to clinical practice is rather slow. To address this issue, the National Institutes of Health launched the Molecular Imaging and Contrast Agents Database (MICAD) in 2005 to provide freely accessible online information regarding molecular imaging probes and contrast agents for the imaging community. While compiling information regarding imaging agents published in peer-reviewed journals, the MICAD editors have observed that some important information regarding the characterization of a contrast agent is not consistently reported. This makes it difficult for investigators to evaluate and meta-analyze data generated from different studies of imaging agents, especially for the agents based on nanoparticles. This article is intended to serve as a guideline for new investigators for the characterization of preclinical studies performed with nanoparticle-based MRI contrast agents. The common characterization parameters are summarized into seven categories: contrast agent designation, physicochemical properties, magnetic properties, in vitro studies, animal studies, MRI studies, and toxicity. Although no single set of parameters is suitable to define the properties of the various types of contrast agents, it is essential to ensure that these agents meet certain quality control parameters at the preclinical stage, so that they can be used without delay for clinical studies.

  3. Uptake of myocardial imaging agents by rejected hearts

    Bergsland, J.; Carr, E.A.; Carroll, M.; Wright, J.W.; Feldman, M.J.; Massucci, J.; Bhayana, J.N.; Gona, J.M.

    1985-01-01

    Technetium 99 m pyrophosphate, Gallium 67 and Thallium 201 uptakes were measured in heterotopically transplanted rat hearts. Five days after transplantation, Technetium 99 m pyrophosphate, and Gallium 67 uptakes were significantly higher in allogeneic grafts than in syngeneic grafts. At an early stage of rejection (three days after transplantation), only Technetium 99 m pyrophosphate uptake in the left ventricle of allogeneic grafts showed a significant difference (p less than 0.04). At five days, Thallium 201 uptake was significantly lower in allo- than syngeneic grafts. There was a positive correlation between radionuclide uptake and histologic degree of rejection for Technetium 99 m pyrophosphate and Gallium 67 while Thallium 201 uptake correlated negatively. Analysis of variance revealed that hearts with no or minimal rejection had statistically different uptakes than hearts with mild to moderate rejection. These results suggest that uptake of imaging agents might be useful in the diagnosis of rejection of the transplanted heart

  4. Tracers and contrast agents in cardiovascular imaging: present and future

    Marmion, M.; Deutsch, E.

    1996-01-01

    This brief article addresses the current status and future potential of nuclear medicine, X-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) imaging in the diagnosis of cardiovascular diseases. The currently perceived advantages and disadvantages, as well as the possible future roles, of each of the modalities with regard to the evaluation of coronary artery disease are delineated. The certain advent of Mr and US myocardial contrast agents, combined with the inexorable pressures of health care reform, will alter the future usage patterns of all four modalities. Future debates about which modality should be used in which clinical situation will be based not on 'anatomy vs function', nor on the issues of cost effectiveness and patient outcomes

  5. Kit for preparing a technetium-99m myocardial imaging agent

    Woulfe, S.R.; Deutsch, E.A.; Dyszlewski, M.; Neumann, W.L.

    1992-01-01

    This patent describes a kit for preparing a technetium 99m myocardial imaging agent. It comprises a first vial containing a lyophilized pyrogen free, sterile mixture of an effective reducing agent and a first ligand having the following general formula: wherein the R 1 groups may be the same or different and are selected from the group consisting of hydrogen, hydroxy, C 1 - C 5 alkyl, C 1 - C 5 alkyl substituted by hydroxyl, ether, ester, amide, ketone, aldehyde and nitrile; the R 2 groups may be the same or different and are selected from the group consisting of hydrogen, hydroxy, C 1 - C 5 alkyl, C 1 - C 5 alkyl substituted by hydroxyl, ether, ester, amide, ketone, aldehyde, and nitrile; the X and Y groups may be the same or different and are selected from the group consisting of oxygen and sulfur; and n is equal to 1 or 2; and a second vial containing a lyophilized pyrogen free, sterile protected salt of a phosphine ligand

  6. Contrast agents for tumor diagnosis in magnetic resonance imaging

    Goto, Rensuke; Doi, Hisayoshi; Okada, Shoji [University of Shizuoka (Japan). School of Pharmaceutical Science; Yano, Masayuki; Katano, Susumu; Nakajima, Nobuaki

    1992-01-01

    In order to develop contrast agents for tumor diagnosis in magnetic resonance imaging (MRI), we investigated the effects of several gadolinium complexes on T{sub 1} relaxation time of proton in some tissues of Ehrlich solid tumor-bearing mice. L-Aspartic acid, L-glutamic acid, DL-homocysteine, L-glutamyl-glutamic acid, glutathione, sperimidine and ethylenediaminetetrakis (methylenephosphate) (EDTMP) were used as ligands for Gd{sup 3+}. Since each Gd-complex could not be purified except Gd-EDTMP, the mixture of GdCl{sub 3} and a ligand was administered intravenously. Among the compounds tested, the mixture of aspartic acid, glutathione or spermidine with GdCl{sub 3} showed almost the same or above reduction of T{sub 1} relaxation times in the tumor tissue compared with Gd-diethylenetriamine pentaacetic acid (Gd-DTPA) which is used clinically. Furthermore, the contrast-enhancing effect of the three mixtures in the tumor was observed by in vivo T{sub 1}-weighted magnetic resonance imaging. The in vivo tissue distribution using radioactive {sup 153}Gd{sup 3+} showed that these mixtures mentioned above were also taken up more highly in the tumor than {sup 153}GdCl{sub 3} itself and {sup 153}Gd-DTPA, suggesting the formation of Gd-complexes. However, the overall tissue distribution of the mixtures was similar to that of {sup 153}GdCl{sub 3} because the Gd-complexes were not purified. Gd-EDTMP exhibited the almost same effects with Gd-DTPA as a contrast agent. (author).

  7. Hepatobiliary fascioliasis in non-endemic zones: a surprise diagnosis.

    Jha, Ashish Kumar; Goenka, Mahesh Kumar; Goenka, Usha; Chakrabarti, Amrita

    2013-03-01

    Fascioliasis is a zoonotic infection caused by Fasciola hepatica. Because of population migration and international food trade, human fascioliasis is being an increasingly recognised entity in nonendemic zones. In most parts of Asia, hepatobiliary fascioliasis is sporadic. Human hepatobiliary infection by this trematode has two distinct phases: an acute hepatic phase and a chronic biliary phase. Hepatobiliary infection is mostly associated with intense peripheral eosinophilia. In addition to classically defined hepatic phase and biliary phase fascioliasis, some cases may have an overlap of these two phases. Chronic liver abscess formation is a rare presentation. We describe a surprise case of hepatobiliary fascioliasis who presented to us with liver abscess without intense peripheral eosinophilia, a rare presentation of human fascioliasis especially in non-endemic zones. Copyright © 2013 Arab Journal of Gastroenterology. Published by Elsevier Ltd. All rights reserved.

  8. Comparison of radiation dosimetry for several potential myocardial imaging agents

    Watson, E.E.; Stabin, M.G; Goodman, M.M.; Knapp, F.F. Jr.; Srivastava, P.C.

    1986-01-01

    Although myocardial imaging is currently dominated by Tl-201, several alternative agents with improved physiologic or radionuclidic properties have been proposed. Based on human and animal studies in the literature, the metabolism of several of these compounds was studied for the purpose of generating radiation dose estimates. Dose estimates are listed for several I-123-labeled free fatty acids, an I-123-labeled phosphonium compound, Rb-82, Cu-64, F-18 FDG (all compounds which are taken up by the normal myocardium), and for Tc-99m pyrophosphate (PYP) (which localizes in myocardial infarcts). Dose estimates could not be generated for C-11 palmitate, but his compound was included in a comparison of myocardial retention times. For the I-123-labeled compounds, I-124 was included as a contaminant in generating the dose estimates. Radiation doses were lowest for Rb-82 (gonads 0.3-0.4 Gy/MBq, kidneys 8.6 Gy/MBq). Doses for the I-123-labeled fatty acids were similar to one another, with IPPA being the lowest (gonads 15 Gy/MBq, heart wall 18 Gy/MBq). Doses for Tc-99m PYP were also low (gonads 4-7 Gy/MBq, heart wall 4 Gy/MBq, skeleton 15 Gy/MBq). The desirability of these compounds is discussed briefly, considering half-life, imaging mode and energy, and dosimetry, including a comparison of the effective whole body dose equivalents. 37 references, 11 tables

  9. Nicotinic {alpha}4{beta}2 receptor imaging agents

    Pichika, Rama [Brain Imaging Center, Department of Psychiatry and Human Behavior, University of California, Irvine, CA 92697-3960 (United States); Easwaramoorthy, Balasubramaniam [Brain Imaging Center, Department of Psychiatry and Human Behavior, University of California, Irvine, CA 92697-3960 (United States); Collins, Daphne [Brain Imaging Center, Department of Psychiatry and Human Behavior, University of California, Irvine, CA 92697-3960 (United States); Christian, Bradley T. [Department of Nuclear Medicine, Kettering Medical Center, Dayton, OH 45429 (United States); Shi, Bingzhi [Department of Nuclear Medicine, Kettering Medical Center, Dayton, OH 45429 (United States); Narayanan, Tanjore K. [Department of Nuclear Medicine, Kettering Medical Center, Dayton, OH 45429 (United States); Potkin, Steven G. [Brain Imaging Center, Department of Psychiatry and Human Behavior, University of California, Irvine, CA 92697-3960 (United States); Mukherjee, Jogeshwar [Brain Imaging Center, Department of Psychiatry and Human Behavior, University of California, Irvine, CA 92697-3960 (United States)]. E-mail: j.mukherjee@uci.edu

    2006-04-15

    The {alpha}4{beta}2 nicotinic acetylcholine receptor (nAChR) has been implicated in various neurodegenerative diseases. Optimal positron emission tomography (PET) imaging agents are therefore highly desired for this receptor. We report here the development and initial evaluation of 2-fluoro-3-[2-((S)-3-pyrrolinyl)methoxy]pyridine (nifene). In vitro binding affinity of nifene in rat brain homogenate using {sup 3}H-cytisine exhibited a K {sub i}=0.50 nM for the {alpha}4{beta}2 sites. The radiosynthesis of 2-{sup 18}F-fluoro-3-[2-((S)-3-pyrrolinyl)methoxy]pyridine ({sup 18}F-nifene) was accomplished in 2.5 h with an overall radiochemical yield of 40-50%, decay corrected. The specific activity was estimated to be approx. 37-185 GBq/{mu}mol. In vitro autoradiography in rat brain slices indicated selective binding of {sup 18}F-nifene to anteroventral thalamic (AVT) nucleus, thalamus, subiculum, striata, cortex and other regions consistent with {alpha}4{beta}2 receptor distribution. Rat cerebellum showed some binding, whereas regions in the hippocampus had the lowest binding. The highest ratio of >13 between AVT and cerebellum was measured for {sup 18}F-nifene in rat brain slices. The specific binding was reduced (>95%) by 300 {mu}M nicotine in these brain regions. Positron emission tomography imaging study of {sup 18}F-nifene (130 MBq) in anesthetized rhesus monkey was carried out using an ECAT EXACT HR+ scanner. PET study showed selective maximal uptake in the regions of the anterior medial thalamus, ventro-lateral thalamus, lateral geniculate, cingulate gyrus, temporal cortex including the subiculum. The cerebellum in the monkeys showed lower binding than the other regions. Thalamus-to-cerebellum ratio peaked at 30-35 min postinjection to a value of 2.2 and subsequently reduced. The faster binding profile of {sup 18}F-nifene indicates promise as a PET imaging agent and thus needs further evaluation.

  10. Hepatobiliary cystadenoma can protrude and grow into the bile ducts.

    Gadzijev, E M; Pleskovic, A; Stanisavljevic, D; Ferlan-Marolt, V; Trotovsek, B

    1998-01-01

    To evaluate the phenomenon and the potential reasons for protrusion and growth of hepatobiliary cystadenoma into the extrahepatic bile ducts in our patients, accomplished by a review of the data regarding hepatobiliary cystadenomas published elsewhere. In a retrospective open study conducted over the last eight years, five patients with hepatobiliary cystadenoma and one patient with hepatobiliary cystadenocarcinoma were operated on. All the patients were females aged between 25 to 61 years. Diagnostic procedures, laboratory, operative and histopathological findings and treatment were evaluated. Most of our patients were found to have hepatobiliary cystadenoma located in the left surgical liver. In three out of five patients with HBC mesenchymal stroma was histologically detected. In two of the three, protrusion and growth into the extrahepatic bile ducts was found. Considering the pathogenesis, location and the morphology of HBC, the mesenchymal stroma may present the competent potential for intraductal progression of the tumor. Radical excision should be performed for successful treatment of hepatobiliary cystadenomas, because of the potential for reoccurrence.

  11. 18F-Labelled metomidate analogues as adrenocortical imaging agents

    Erlandsson, Maria; Karimi, Farhad; Lindhe, Orjan; Langstroem, Bengt

    2009-01-01

    Introduction: Two- and one-step syntheses of 18 F-labelled analogues of metomidate, such as 2-[ 18 F]fluoroethyl 1-[(1R)-1-phenylethyl]-1H-imidazole-5-carboxylate (1), 2-[ 18 F]fluoroethyl 1-[(1R)-1-(4-chlorophenyl)ethyl]-1H-imidazole-5-carboxylate (2), 2-[ 18 F]fluoroethyl 1-[(1R)-1-(4-bromophenyl)ethyl]-1H-imidazole-5-carboxylate (3), 3-[ 18 F]fluoropropyl 1-[(1R)-1-(4-bromophenyl)ethyl]-1H-imidazole-5-carboxylate (4) and 3-[ 18 F]fluoropropyl 1-[(1R)-1-phenylethyl]-1H-imidazole-5-carboxylate (5) are presented. Methods: Analogues 1-5 were prepared by a two-step reaction sequence that started with the synthesis of either 2-[ 18 F]fluoroethyl 4-methylbenzenesulfonate or 3-[ 18 F]fluoropropyl 4-methylbenzenesulfonate. These were used as 18 F-alkylating agents in the second step, in which they reacted with the ammonium salt of a 1-[(1R)-1-phenylethyl]-1H-imidazole-5-carboxylic acid. One-step-labelling syntheses of 1, 2 and 5 were also explored. Analogues 1-4 were biologically validated by frozen-section autoradiography and organ distribution. Metabolite analysis was performed for 2 and 3. Results: The radiochemical yield of the two-step synthesis was in the range of 10-29% and that of the one-step synthesis was 25-37%. Using microwave irradiation in the one-step synthesis of 1 and 2 increased the radiochemical yield to 46±3% and 79±30%, respectively. Conclusion: Both the frozen-section autoradiography and organ distribution results indicated that analogue 2 has a potential as an adrenocortical imaging agent, having the highest degree of specific adrenal binding and best ratio of adrenal to organ uptake among the compounds studied.

  12. A review of 99mTc labeled myocardial imaging agents for tumor-positive imaging

    Xing Shian; Zhang Yongxue; An Rui

    2002-01-01

    The tumor-positive imaging with high sensitivity and specificity was useful in primary tumor and recurrences and metastases. The 99m Tc labeled myocardial imaging agents are easily available and stable and the radiochemical purity is high. 99m Tc is the preferred choice in routine works because its physical properties. The preparation, quality control, mechanism of accumulation and the clinical use of 99m Tc-sestamibi, 99m Tc-tetrofosmin, 99m Tc-furifosmin, and 99m Tc-N-NOET were reviewed

  13. Radioiodinated carnitine and acylcarnitine analogs as potential myocardial imaging agents

    McConnell, D.S.

    1991-01-01

    R-carnitine is extremely important in mammalian energy metabolism. Gamma-butyrobetaine, the immediate biosynthetic precursor to R-carnitine, is synthesized in many organs. However, only liver can hydroxylate gamma-butyrobetaine to carnitine. Thus the transport of carnitine from its site of synthesis to the site of utilization is of utmost importance. Carnitine is found in highest concentration in cardiac and skeletal muscle, where it is required for the transport of fatty acids into the mitochondria. Before fatty acids are utilized as fuel for the myocyte by beta-oxidation, they are bound to carnitine as an acylcarnitine ester at the 3-hydroxyl, and transported across the micochondrial membranes. R,S-Carnitine has been shown to be taken up by myocytes. The author has begun a study on the use of carnitine derivatives as potential carriers for the site-specific delivery of radioiodine to bidning sites in the myocardium. Such agents labeled with a gamma-emitting nuclide such as iodine-123 would be useful for the noninvasive imaging of these tissues. The aim was to synthesize a variety of radiolabeled analogs of carnitine and acylcarnitine to address questions of transport, binding and availability for myocardial metabolism. These analogs consist of N-alkylated derivatives of carnitine, acylcarnitine esters as well as carnitine amides and ethers. One C-alkylated derivative showed interesting biodistribution, elevated myocardial uptake and competition with carnitine for binding in the myocardium

  14. Development of Iron Doped Silicon Nanoparticles as Bimodal Imaging Agents

    Singh, Mani P.; Atkins, Tonya M.; Muthuswamy, Elayaraja; Kamali, Saeed; Tu, Chuqiao; Louie, Angelique Y.; Kauzlarich, Susan M.

    2012-01-01

    We demonstrate the synthesis of water-soluble allylamine terminated Fe doped Si (SixFe) nanoparticles as bimodal agents for optical and magnetic imaging. The preparation involves the synthesis of a single source iron containing precursor, Na4Si4 with x% Fe (x = 1, 5, 10), and its subsequent reaction with NH4Br to produce hydrogen terminated SixFe nanoparticles. The hydrogen-capped nanoparticles are further terminated with allylamine via thermal hydrosilylation. Transmission electron microscopy (TEM) indicates that the average particle diameter is ~3.0±1.0 nm. The Si5Fe nanoparticles show strong photoluminescence quantum yield in water (~ 10 %) with significant T2 contrast (r2/r1value of 4.31). Electron paramagnetic resonance (EPR) and Mössbauer spectroscopies indicate that iron in the nanoparticles is in the +3 oxidation state. Analysis of cytotoxicity using the resazurin assay on HepG2 liver cells indicates that the particles have minimal toxicity. PMID:22616623

  15. DTPA: Bis benzimidazole as multi model imaging agent

    Srivastava, Vikas; Tiwari, A.K.; Sharma, H.; Sharma, R.; Mishra, A.K.

    2010-01-01

    Full text: The DTPA bis benzimidazole analogue has been tested for radiopharmaceutical efficacy. The radiolabelling was found more then 98% after 8 hrs and blood kinetics was fast. The compound was also tested for optical imaging agent. The Eu 3+ ion has an absorption band in the visible spectrum (578-582 nm) whose wavelength is very sensitive to even small changes in the coordination environment. Although the intensity of this 7F0 → 5D0 transition is low, the bands are relatively narrow, which allows distinguishing different coordination states of the metal. For Eu 3+ complexes which have two differently hydrated forms in aqueous solution, one observes two absorption bands belonging to the two species. High-resolution UV-visible spectra were recorded in aqueous solutions which show a temperature invariant absorption with two distinct, temperature-dependent absorption bands. The intensity ratio of these two bands changes with temperature: the band at shorter wavelengths is decreasing very slightly, while that at longer wavelengths is increasing with the temperature. The ratio of the integrals of the two bands is related to the equilibrium constant, and its temperature dependence yields the reaction enthalpy and entropy

  16. Meeting Report: High-Throughput Technologies for In Vivo Imaging Agents

    Robert J. Gillies

    2005-04-01

    Full Text Available Combinatorial chemistry and high-throughput screening have become standard tools for discovering new drug candidates with suitable pharmacological properties. Now, those same technologies are starting to be applied to the problem of discovering novel in vivo imaging agents. Important differences in the biological and pharmacological properties needed for imaging agents, compared to those for a therapeutic agent, require new screening methods that emphasize those characteristics, such as optimized residence time and tissue specificity, that make for a good imaging agent candidate.

  17. Ultrasound contrast-agent improves imaging of lower limb occlusive disease

    Eiberg, J P; Hansen, M A; Jensen, F

    2003-01-01

    to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA).......to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA)....

  18. In vivo Photoacoustic Imaging of Prostate Cancer Using Targeted Contrast Agent

    2016-11-01

    AD______________ AWARD NUMBER: W81XWH-14-1-0242 TITLE: In Vivo Photoacoustic Imaging of Prostate Cancer Using Targeted Contrast Agent PRINCIPAL...TITLE AND SUBTITLE In vivo Photoacoustic Imaging of Prostate Cancer Using T argeted Contrast Agent 5a. CONTRACT NUMBER W81XWH-14-1-0242 5b. GRANT...diagnose prostate cancer based on the near-infrared optical absorption of either endogenous tissue constituents or exogenous contrast agents . Although

  19. Imaging tumor hypoxia: Blood-borne delivery of imaging agents is fundamentally different in hypoxia subtypes

    Peter Vaupel

    2014-03-01

    Full Text Available Hypoxic tissue subvolumes are a hallmark feature of solid malignant tumors, relevant for cancer therapy and patient outcome because they increase both the intrinsic aggressiveness of tumor cells and their resistance to several commonly used anticancer strategies. Pathogenetic mechanisms leading to hypoxia are diverse, may coexist within the same tumor and are commonly grouped according to the duration of their effects. Chronic hypoxia is mainly caused by diffusion limitations resulting from enlarged intercapillary distances and adverse diffusion geometries and — to a lesser extent — by hypoxemia, compromised perfusion or long-lasting microregional flow stops. Conversely, acute hypoxia preferentially results from transient disruptions in perfusion. While each of these features of the tumor microenvironment can contribute to a critical reduction of oxygen availability, the delivery of imaging agents (as well as nutrients and anticancer agents may be compromised or remain unaffected. Thus, a critical appraisal of the effects of the various mechanisms leading to hypoxia with regard to the blood-borne delivery of imaging agents is necessary to judge their ability to correctly represent the hypoxic phenotype of solid malignancies.

  20. Radioiodinated fenetylline (captagon): A new potential brain imaging agent

    Biersack, H.J.; Klunenberg, H.; Breuel, H.P.; Reske, S.N.; Reichmann, K.; Winkler, C.

    1984-01-01

    Since about 2 years /sup 123/I-labeled iodamphetamines (IMP) and diamines (HIPDM) have been used for scintigraphic brain investigations. As another possibly useful brain imaging agent we studied radioiodine labeled Fenetylline which is metabolized into amphetamine. Thirty wistar rats were injected 5 μCi /sup 125/I-IMP and 2 μCi /sup 131/I-Fenetylline each simultaneously. The animals were sacrificed 5,10,15,30,60, and 120 min. p.i. The radioactivity content of tissue specimens (brain, cerebellum, liver, kidney, lung, myocardium, muscle) was measured in a well-counter (% dose/g tissue). In 2 dogs sequential cerebral scintigraphy was performed following the injection of 0.5 mCi /sup 131/I-Fenetylline. Three patients underwent brain SPECT after injection of 6.5 mCi /sup 123/I-Fenetylline. The results can be summarized as follows: after 5/10 min. p.i. Fenetylline-uptake in the brain of rats was 1.0/1.3% compared to 1.3/1.9% (IMP). A fast decrease of cerebral Fenetylline concentration was established after 30 (0.2%) and 60 (0.5%) min. The canine and human sequential scintigraphy revealed a rapid cerebral uptake (maximum after 2-10 min.) suggesting that Fenetylline is concentrated in the brain as a function of cerebral blood flow. From the first clinical findings it appears to be likely that the combined use of /sup 123/I labelled IMP and Fenetylline for SPECT may lead to a more differentiated evaluation of cerebral blood flow and metabolism

  1. Application of da Vinci surgical robotic system in hepatobiliary surgery

    Chen Jiahai

    2018-01-01

    Full Text Available The development of minimally invasive surgery has brought a revolutionary change to surgery techniques, and endoscopic surgical robots, especially Da Vinci robotic surgical system, has further broaden the scope of minimally invasive surgery, which has been applied in a variety of surgical fields including hepatobiliary surgery. Today, the application of Da Vinci surgical robot can cover most of the operations in hepatobiliary surgery which has proved to be safe and practical. What’s more, many clinical studies in recent years have showed that Da Vinci surgical system is superior to traditional laparoscopy. This paper summarize the advantage and disadvantage of Da Vinci surgical system, and outlines the current status of and future perspectives on the robot-assisted hepatobiliary surgery based on the cases reports in recent years of the application of Da Vinci surgical robot.

  2. Prospective of 68Ga Radionuclide Contribution to the Development of Imaging Agents for Infection and Inflammation

    2018-01-01

    During the last decade, the utilization of 68Ga for the development of imaging agents has increased considerably with the leading position in the oncology. The imaging of infection and inflammation is lagging despite strong unmet medical needs. This review presents the potential routes for the development of 68Ga-based agents for the imaging and quantification of infection and inflammation in various diseases and connection of the diagnosis to the treatment for the individualized patient management. PMID:29531507

  3. Detection of common bile duct stone by hepatobiliary scintigraphy

    Itoh, Hisao; Sakai, Toyohiko; Takahashi, Norio

    1991-01-01

    Hepatobiliary scintigraphy and direct X-ray cholangiography were compared in 29 patients with common bile duct (CBD) stones confirmed at surgery. The scintigraphic findings included no visualization of the biliary system (NV), pooling of bile in the biliary system (PB), prolonged transit time over 60 min (PTT), filling defect in the CBD image (FD), and reflux of bile toward the intrahepatic ducts after gallbladder stimulation (RB). The positive rates of NV, PB, PTT, FD, and RB in patients with CBD stones were 7%, 31%, 17%, 48%, and 14%, respectively. One or more of these five findings was found in 83%. Although the NV was a useful finding suggesting complete obstruction of the CBD, it shared little in the diagnosis of CBD stone. The positive rate of the PB was relatively high and it would be a useful finding as an indication of the presence of passage disturbance of the CBD. The PB was usually accompanied by the FD. The PTT had some usefulness in the detection of incomplete obstruction of the CBD in patients with a visualized gallbladder. In patients with no visualization of the gallbladder, however, the transit time tended to be shorter than that of gallbladder visualized patients. Therefore, the judgement of PTT in patients with no visualized gallbladder needed another criteria. The FD was the most frequent among the five findings and the sites of FD correlated well with CBD stones on direct X-ray cholangiography. The FD would be a reliable finding indicating CBD stone or CBD stenosis. Although the RB was a finding limited in patients with a visualized gallbladder, it seemed to be a helpful findings for the detection of CBD stone in patients with a mildly dilated CBD. (author)

  4. Ultrasound contrast agent imaging: Real-time imaging of the superharmonics

    Peruzzini, D.; Viti, J. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Tortoli, P. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Verweij, M. D. [Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands); Jong, N. de; Vos, H. J., E-mail: h.vos@erasmusmc.nl [Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands)

    2015-10-28

    Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher harmonics, i.e. “superharmonic” imaging, shows better contrast. However, the superharmonic scattering has a lower signal level compared to e.g. second harmonic signals. This study investigates the contrast-to-tissue ratio (CTR) and signal to noise ratio (SNR) of superharmonic UCA scattering in a tissue/vessel mimicking phantom using a real-time clinical scanner. Numerical simulations were performed to estimate the level of harmonics generated by the microbubbles. Data were acquired with a custom built dual-frequency cardiac phased array probe. Fundamental real-time images were produced while beam formed radiofrequency (RF) data was stored for further offline processing. The phantom consisted of a cavity filled with UCA surrounded by tissue mimicking material. The acoustic pressure in the cavity of the phantom was 110 kPa (MI = 0.11) ensuring non-destructivity of UCA. After processing of the acquired data from the phantom, the UCA-filled cavity could be clearly observed in the images, while tissue signals were suppressed at or below the noise floor. The measured CTR values were 36 dB, >38 dB, and >32 dB, for the second, third, and fourth harmonic respectively, which were in agreement with those reported earlier for preliminary contrast superharmonic imaging. The single frame SNR values (in which ‘signal’ denotes the signal level from the UCA area) were 23 dB, 18 dB, and 11 dB, respectively. This indicates that noise, and not the tissue signal, is the limiting factor for the UCA detection when using the superharmonics in nondestructive mode.

  5. Microbubble embedded with upconversion nanoparticles as a bimodal contrast agent for fluorescence and ultrasound imaging

    Jin, Birui; Lin, Min; You, Minli; Xu, Feng; Lu, Tianjian; Zong, Yujin; Wan, Mingxi; Duan, Zhenfeng

    2015-01-01

    Bimodal imaging offers additional imaging signal thus finds wide spread application in clinical diagnostic imaging. Fluorescence/ultrasound bimodal imaging contrast agent using fluorescent dyes or quantum dots for fluorescence signal has emerged as a promising method, which however requires visible light or UV irradiation resulting in photobleaching, photoblinking, auto-fluorescence and limited tissue penetration depth. To surmount these problems, we developed a novel bimodal contrast agent using layer-by-layer assembly of upconversion nanoparticles onto the surface of microbubbles. The resulting microbubbles with average size of 2 μm provide enhanced ultrasound echo for ultrasound imaging and upconversion emission upon near infrared irradiation for fluorescence imaging. The developed bimodal contrast agent holds great potential to be applied in ultrasound target technique for targeted diseases diagnostics and therapy. (paper)

  6. [Hepatobiliary System Diseases as the Predictors of Psoriasis Progression].

    Smirnova, S V; Barilo, A A; Smolnikova, M V

    2016-01-01

    To assess the state of the hepatobiliary system in psoriasis andpsoriatic arthritis in order to establish a causal relationship and to identify clinical and functional predictors of psoriatic disease progression. The study includedpatients with extensive psoriasis vulgaris (n = 175) aged 18 to 66 years old and healthy donors (n = 30), matched by sex and age: Group 1--patients with psoriasis (PS, n = 77), group 2--patients with psoriatic arthritis (PsA, n = 98), group 3--control. The evaluation of functional state of the hepatobiliary system was performed by the analysis of the clinical and anamnestic data and by the laboratory-instrumental methods. We identified predictors of psoriasis: triggers (stress and nutritionalfactor), increased total bilirubin, aspartate aminotransferase, alkaline phosphatase, gamma-glutamyl transferase, eosinophilia, giardiasis, carriers of hepatitis C virus, ductal changes andfocal leisons in the liver, thickening of the walls of the gallbladder detected by ultrasound. Predictors ofpsoriatic arthritis: age over 50 years, dyspeptic complaints, the presence of hepatobiliary system diseases, the positive right hypochondrium syndrome, the clinical symptoms of chronic cholecystitis, excess body weight, high levels of bilirubin, cholesterol and low density lipoprotein, hepatomegaly, non-alcoholic fatty liver disease. High activity of hepatocytes cytolysis, cholestasis, inflammation, metabolic disorders let us considerpsoriatic arthritis as a severe clinical stage psoriatic disease when the hepatobiliary system, in turn, is one of the main target organs in systemic psoriatic process. Non-alcoholic fatty liver disease and chronic cholecystitis are predictors of psoriatic disease progression.

  7. Spectral Imaging Technology-Based Evaluation of Radiation Treatment Planning to Remove Contrast Agent Artifacts.

    Yi-Qun, Xu; Wei, Liu; Xin-Ye, Ni

    2016-10-01

    This study employs dual-source computed tomography single-spectrum imaging to evaluate the effects of contrast agent artifact removal and the computational accuracy of radiotherapy treatment planning improvement. The phantom, including the contrast agent, was used in all experiments. The amounts of iodine in the contrast agent were 30, 15, 7.5, and 0.75 g/100 mL. Two images with different energy values were scanned and captured using dual-source computed tomography (80 and 140 kV). To obtain a fused image, 2 groups of images were processed using single-energy spectrum imaging technology. The Pinnacle planning system was used to measure the computed tomography values of the contrast agent and the surrounding phantom tissue. The difference between radiotherapy treatment planning based on 80 kV, 140 kV, and energy spectrum image was analyzed. For the image with high iodine concentration, the quality of the energy spectrum-fused image was the highest, followed by that of the 140-kV image. That of the 80-kV image was the worst. The difference in the radiotherapy treatment results among the 3 models was significant. When the concentration of iodine was 30 g/100 mL and the distance from the contrast agent at the dose measurement point was 1 cm, the deviation values (P) were 5.95% and 2.20% when image treatment planning was based on 80 and 140 kV, respectively. When the concentration of iodine was 15 g/100 mL, deviation values (P) were -2.64% and -1.69%. Dual-source computed tomography single-energy spectral imaging technology can remove contrast agent artifacts to improve the calculated dose accuracy in radiotherapy treatment planning. © The Author(s) 2015.

  8. Microscopic validation of whole mouse micro-metastatic tumor imaging agents using cryo-imaging and sliding organ image registration

    Liu, Yiqiao; Zhou, Bo; Qutaish, Mohammed; Wilson, David L.

    2016-03-01

    We created a metastasis imaging, analysis platform consisting of software and multi-spectral cryo-imaging system suitable for evaluating emerging imaging agents targeting micro-metastatic tumor. We analyzed CREKA-Gd in MRI, followed by cryo-imaging which repeatedly sectioned and tiled microscope images of the tissue block face, providing anatomical bright field and molecular fluorescence, enabling 3D microscopic imaging of the entire mouse with single metastatic cell sensitivity. To register MRI volumes to the cryo bright field reference, we used our standard mutual information, non-rigid registration which proceeded: preprocess --> affine --> B-spline non-rigid 3D registration. In this report, we created two modified approaches: mask where we registered locally over a smaller rectangular solid, and sliding organ. Briefly, in sliding organ, we segmented the organ, registered the organ and body volumes separately and combined results. Though sliding organ required manual annotation, it provided the best result as a standard to measure other registration methods. Regularization parameters for standard and mask methods were optimized in a grid search. Evaluations consisted of DICE, and visual scoring of a checkerboard display. Standard had accuracy of 2 voxels in all regions except near the kidney, where there were 5 voxels sliding. After mask and sliding organ correction, kidneys sliding were within 2 voxels, and Dice overlap increased 4%-10% in mask compared to standard. Mask generated comparable results with sliding organ and allowed a semi-automatic process.

  9. Feasibility of semiautomated MR volumetry using gadoxetic acid-enhanced MRI at hepatobiliary phase for living liver donors.

    Lee, Jeongjin; Kim, Kyoung Won; Kim, So Yeon; Kim, Bohyoung; Lee, So Jung; Kim, Hyoung Jung; Lee, Jong Seok; Lee, Moon Gyu; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu

    2014-09-01

    To assess the feasibility of semiautomated MR volumetry using gadoxetic acid-enhanced MRI at the hepatobiliary phase compared with manual CT volumetry. Forty potential live liver donor candidates who underwent MR and CT on the same day, were included in our study. Semiautomated MR volumetry was performed using gadoxetic acid-enhanced MRI at the hepatobiliary phase. We performed the quadratic MR image division for correction of the bias field inhomogeneity. With manual CT volumetry as the reference standard, we calculated the average volume measurement error of the semiautomated MR volumetry. We also calculated the mean of the number and time of the manual editing, edited volume, and total processing time. The average volume measurement errors of the semiautomated MR volumetry were 2.35% ± 1.22%. The average values of the numbers of editing, operation times of manual editing, edited volumes, and total processing time for the semiautomated MR volumetry were 1.9 ± 0.6, 8.1 ± 2.7 s, 12.4 ± 8.8 mL, and 11.7 ± 2.9 s, respectively. Semiautomated liver MR volumetry using hepatobiliary phase gadoxetic acid-enhanced MRI with the quadratic MR image division is a reliable, easy, and fast tool to measure liver volume in potential living liver donors. Copyright © 2013 Wiley Periodicals, Inc.

  10. Gastric Reflux on Routine Tc-99m DISIDA hepatobiliary Scintigraphy

    Lee, Kang Wook; Lee, Heon Young [Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    1995-06-15

    Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid derivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m-DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows: 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenpscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  11. Gastric Reflux on Routine Tc-99m DISIDA hepatobiliary Scintigraphy

    Lee, Kang Wook; Lee, Heon Young

    1995-01-01

    Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid derivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m-DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows: 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenpscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  12. [Utilization of polymeric micelle magnetic resonance imaging (MRI) contrast agent for theranostic system].

    Shiraishi, Kouichi

    2013-01-01

    We applied a polymeric micelle carrier system for the targeting of a magnetic resonance imaging (MRI) contrast agent. Prepared polymeric micelle MRI contrast agent exhibited a long circulation characteristic in blood, and considerable amount of the contrast agent was found to accumulate in colon 26 solid tumor by the EPR effect. The signal intensities of tumor area showed 2-folds increase in T1-weighted images at 24 h after i.v. injection. To observe enhancement of the EPR effect by Cderiv pretreatment on tumor targeting, we used the contrast agent for the evaluation by means of MRI. Cderiv pretreatment significantly enhanced tumor accumulation of the contrast agent. Interestingly, very high signal intensity in tumor region was found at 24 h after the contrast agent injection in Cderiv pretreated mice. The contrast agent visualized a microenvironmental change in tumor. These results indicate that the contrast agent exhibits potential use for tumor diagnostic agent. To combine with a polymeric micelle carrier system for therapeutic agent, the usage of the combination makes a new concept of "theranostic" for a better cancer treatment.

  13. Cranial nerve contrast using nerve-specific fluorophores improved by paired-agent imaging with indocyanine green as a control agent

    Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.

    2017-09-01

    Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.

  14. Development of a Multifaceted Ovarian Cancer Therapeutic and Imaging Agent

    2011-04-01

    by 1-ethyl-3- [3-(dimethylamino) propyl ]carbodiimide (EDC) and N-hydroxysulfonosuccinimide (SNHS) at pH 5.5 for 30 min with a molar ratio of...particle-coated migratory substrate that can act as a permanent record of cellular movement. The gold chloride solution was prepared using 0.342 g... Synthesis and clinical Evaluation. Anticancer Agents Med. Chem. McLane, M.A., Joerger, T., Mahmoud, A., 2008. Disintegrins in health and disease. Front

  15. High-Relaxivity MRI Contrast Agents: Where Coordination Chemistry Meets Medical Imaging

    Werner, Eric J.; Datta, Ankona; Jocher, Christoph J.; Raymond, Kenneth N.

    2008-01-15

    The desire to improve and expand the scope of clinical magnetic resonance imaging (MRI) has prompted the search for contrast agents of higher efficiency. The development of better agents requires consideration of the fundamental coordination chemistry of the gadolinium(III) ion and the parameters that affect its efficacy as a proton relaxation agent. In optimizing each parameter, other practical issues such as solubility and in vivo toxicity must also be addressed, making the attainment of safe, high-relaxivity agents a challenging goal. Here we present recent advances in the field, with an emphasis on the hydroxypyridinone family of Gd{sup III} chelates.

  16. Recent advances in 3D computed tomography techniques for simulation and navigation in hepatobiliary pancreatic surgery.

    Uchida, Masafumi

    2014-04-01

    A few years ago it could take several hours to complete a 3D image using a 3D workstation. Thanks to advances in computer science, obtaining results of interest now requires only a few minutes. Many recent 3D workstations or multimedia computers are equipped with onboard 3D virtual patient modeling software, which enables patient-specific preoperative assessment and virtual planning, navigation, and tool positioning. Although medical 3D imaging can now be conducted using various modalities, including computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasonography (US) among others, the highest quality images are obtained using CT data, and CT images are now the most commonly used source of data for 3D simulation and navigation image. If the 2D source image is bad, no amount of 3D image manipulation in software will provide a quality 3D image. In this exhibition, the recent advances in CT imaging technique and 3D visualization of the hepatobiliary and pancreatic abnormalities are featured, including scan and image reconstruction technique, contrast-enhanced techniques, new application of advanced CT scan techniques, and new virtual reality simulation and navigation imaging. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  17. Clinical evaluation of sup(99m)Tc-(Sn)-PI (sup(99m)Tc-(Sn)-pyridoxylidene isoleucine) in the various hepatobiliary disorders

    Kawaguchi, S; Iio, M; Yamada, H; Murata, H; Chiba, K [Tokyo Metropolitan Geriatric Medical Center (Japan)

    1978-12-01

    The purpose of this study is to evaluate the hepatobiliary scanning using sup(99m)Tc-(Sn)-PI in clinical diagnosis of various hepatobiliary disorders. Nineteen patients were scanned with sup(99m)Tc-(Sn)-PI. The results were as follows: 1) The stability of sup(99m)Tc-(Sn)-PI examined by paper chromatography using saline as a solvent showed satisfied result at scanning time. sup(99m)Tc-(Sn)-PI in the blood was assumed to be bound to serum proteins immediately after injection. sup(99m)Tc-(Sn)-PI in the urine was assumed to keep the form of sup(99m)Tc-(Sn)-PI. 2) The appearance times of kidney, liver, bile duct, gallbladder, and intestine in the normal case were 5, 5, 10 and 15 minutes respectively after injection. The peak times of hepatogram in the normal case, drug induced hepatitis and obstructive jaundice were 12, 15 and 18 minutes respectively after injection. The images obtained by sup(99m)Tc-(Sn)-PI was superior to the images obtained by /sup 131/I-BSP. 3) The blood clearance and urinary excretion rate of sup(99m)Tc-(Sn)-PI also provided us clinical usefulness. 4) The scanning of Dubin-Johnson syndrome of sup(99m)Tc-(Sn)-PI showed almost normal hepatobiliary image similar to the sequential scan by /sup 131/I-RB as was reported previously by authors. In conclusion, the hepatobiliary scan using sup(99m)Tc-(Sn)-PI provided clear hepatobiliary images. Other parameters such as blood clearance, urinary excretion rate and diameter of choledochus were also favorable. By combining it with sup(99m)Tc-HIDA a differential diagnosis of congenital jaundice is also expected.

  18. Clinical evaluation of sup(99m)Tc-(Sn)-PI [sup(99m)Tc-(Sn)-pyridoxylidene isoleucine] in the various hepatobiliary disorders

    Kawaguchi, Schinichiro; Iio, Masahiro; Yamada, Hideo; Murata, Hajime; Chiba, Kazuo

    1978-01-01

    The purpose of this study is to evaluate the hepatobiliary scanning using sup(99m)Tc-(Sn)-PI in clinical diagnosis of various hepatobiliary disorders. Nineteen patients were scanned with sup(99m)Tc-(Sn)-PI. The results were as follows: 1) The stability of sup(99m)Tc-(Sn)-PI examined by paper chromatography using saline as a solvent showed satisfied result at scanning time. sup(99m)Tc-(Sn)-PI in the blood was assumed to be bound to serum proteins immediately after injection. sup(99m)Tc-(Sn)-PI in the urine was assumed to keep the form of sup(99m)Tc-(Sn)-PI. 2) The appearance times of kidney, liver, bile duct, gallbladder, and intestine in the normal case were 5, 5, 10 and 15 minutes respectively after injection. The peak times of hepatogram in the normal case, drug induced hepatitis and obstructive jaundice were 12, 15 and 18 minutes respectively after injection. The images obtained by sup(99m)Tc-(Sn)-PI was superior to the images obtained by 131 I-BSP. 3) The blood clearance and urinary excretion rate of sup(99m)Tc-(Sn)-PI also provided us clinical usefulness. 4) The scanning of Dubin-Johnson syndrome of sup(99m)Tc-(Sn)-PI showed almost normal hepatobiliary image similar to the sequential scan by 131 I-RB as was reported previously by authors. In conclusion, the hepatobiliary scan using sup(99m)Tc-(Sn)-PI provided clear hepatobiliary images. Other parameters such as blood clearance, urinary excretion rate and diameter of choledochus were also favorable. By combining it with sup(99m)Tc-HIDA a differential diagnosis of congenital jaundice is also expected. (author)

  19. Sporadic incidence of Fascioliasis detected during hepatobiliary procedures: a study of 18 patients from Sulaimaniyah governorate.

    Hawramy, Tahir Abdullah Hussein; Saeed, Kamal Ahmed; Qaradaghy, Seerwan Hama Sharif; Karboli, Taha Ahmed; Nore, Beston Faiek; Bayati, Noora Hisham Abood

    2012-12-21

    Fascioliasis is an often-neglected zoonotic disease and currently is an emerging infection in Iraq. Fascioliasis has two distinct phases, an acute phase, exhibiting the hepatic migratory stage of the fluke's life cycle, and a chronic biliary phase manifested with the presence of the parasite in the bile ducts through hepatic tissue. The incidence of Fascioliasis in Sulaimaniyah governorate was unexpected observation. We believe that shedding light on this disease in our locality will increase our physician awareness and experience in early detection, treatment in order to avoid unnecessary surgeries. We retrospectively evaluated this disease in terms of the demographic features, clinical presentations, and managements by reviewing the medical records of 18 patients, who were admitted to the Sulaimani Teaching Hospital and Kurdistan Centre for Gastroenterology and Hepatology. Patients were complained from hepatobiliary and/or upper gastrointestinal symptoms and diagnosed accidentally with Fascioliasis during hepatobiliary surgeries and ERCP by direct visualization of the flukes and stone analysis. Elevated liver enzymes, white blood cells count and eosinophilia were notable laboratory indices. The dilated CBD, gallstones, liver cysts and abscess were found common in radiological images. Fascioliasis diagnosed during conventional surgical CBD exploration and choledochodoudenostomy, open cholecystectomy, surgical drainage of liver abscess, ERCP and during gallstone analysis. Fascioliasis is indeed an emerging disease in our locality, but it is often underestimated and ignored. We recommend the differential diagnosis of patients suffering from Rt. Hypochondrial pain, fever and eosinophilia. The watercress ingestion was a common factor in patient's history.

  20. Metal complex-based templates and nanostructures for magnetic resonance/optical multimodal imaging agents

    Galindo Millan, Jealemy

    2012-01-01

    In this thesis, new approaches directed towards simple and functional imaging agents (IAs) for magnetic resonance (MR) and fluorescence multimodal imaging are proposed. In Chapter 3, hybrid silver nanostructures (hAgNSs), grown using a polyamino carboxylic acid scaffold, namely

  1. EPR and DNP Properties of Certain Novel Single Electron Contrast Agents Intended for Oximetric Imaging

    Ardenkjær-Larsen, J. H.; Laursen, I; Leunbach, I.

    1998-01-01

    Parameters of relevance to oximetry with Overhauser magnetic resonance imaging (OMRI) have been measured for three single electron contrast agents of the triphenylmethyl type. The single electron contrast agents are stable and water soluble. Magnetic resonance properties of the agents have been...... examined with electron paramagnetic resonance (EPR), nuclear magnetic resonance (NMR), and dynamic nuclear polarization (DNP) at 9.5 mT in water, isotonic saline, plasma, and blood at 23 and 37°C. The relaxivities of the agents are about 0.2–0.4 mM−1s−1and the DNP enhancements extrapolate close...... to the dipolar limit. The agents have a single, narrow EPR line, which is analyzed as a Voigt function. The linewidth is measured as a function of the agent concentration and the oxygen concentration. The concentration broadenings are about 1–3 μT/mM and the Lorentzian linewidths at infinite dilution are less...

  2. Biochemical Stability Analysis of Nano Scaled Contrast Agents Used in Biomolecular Imaging Detection of Tumor Cells

    Kim, Jennifer; Kyung, Richard

    Imaging contrast agents are materials used to improve the visibility of internal body structures in the imaging process. Many agents that are used for contrast enhancement are now studied empirically and computationally by researchers. Among various imaging techniques, magnetic resonance imaging (MRI) has become a major diagnostic tool in many clinical specialties due to its non-invasive characteristic and its safeness in regards to ionizing radiation exposure. Recently, researchers have prepared aqueous fullerene nanoparticles using electrochemical methods. In this paper, computational simulations of thermodynamic stabilities of nano scaled contrast agents that can be used in biomolecular imaging detection of tumor cells are presented using nanomaterials such as fluorescent functionalized fullerenes. In addition, the stability and safety of different types of contrast agents composed of metal oxide a, b, and c are tested in the imaging process. Through analysis of the computational simulations, the stabilities of the contrast agents, determined by optimized energies of the conformations, are presented. The resulting numerical data are compared. In addition, Density Functional Theory (DFT) is used in order to model the electron properties of the compound.

  3. Use of radiolabeled antibodies as diagnostic imaging agents

    Wang, T.S.T.; Seldin, D.; Fawwaz, R.A.; Srivastava, S.; Olvwole, S.

    1989-01-01

    Recent advances in hybridoma technology have led to the development of monoclonal antibodies to a variety of antigens. The high degree of specificity of such reagents coupled with refinements in instrumentation and production of new radionuclides has rekindled interest in the application of radioimmunoscintigraphy in the diagnosis of various diseases. Although much of the work with monoclonal antibodies has been devoted to the diagnosis and treatment of tumors, increasing use is being made of these agents for the study of nontumor related disorders. This chapter focuses on the application of radioimmunoscintigraphy in the diagnosis of malignancies with a discussion on the other uses, notably those related to the vascular system

  4. Indocyanine green labeled with 123I for dynamic studies of the hepato-biliary system

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub 1 / 2 / = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of 123 I-ICG (in dogs) will be compared to 131 I-rose bengal and bromosulphalein labeled with iodine-125

  5. Molecular imaging agents for SPECT (and SPECT/CT)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  6. Molecular imaging agents for SPECT (and SPECT/CT)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  7. Fluorescence lifetime imaging microscopy using near-infrared contrast agents.

    Nothdurft, R; Sarder, P; Bloch, S; Culver, J; Achilefu, S

    2012-08-01

    Although single-photon fluorescence lifetime imaging microscopy (FLIM) is widely used to image molecular processes using a wide range of excitation wavelengths, the captured emission of this technique is confined to the visible spectrum. Here, we explore the feasibility of utilizing near-infrared (NIR) fluorescent molecular probes with emission >700 nm for FLIM of live cells. The confocal microscope is equipped with a 785 nm laser diode, a red-enhanced photomultiplier tube, and a time-correlated single photon counting card. We demonstrate that our system reports the lifetime distributions of NIR fluorescent dyes, cypate and DTTCI, in cells. In cells labelled separately or jointly with these dyes, NIR FLIM successfully distinguishes their lifetimes, providing a method to sort different cell populations. In addition, lifetime distributions of cells co-incubated with these dyes allow estimate of the dyes' relative concentrations in complex cellular microenvironments. With the heightened interest in fluorescence lifetime-based small animal imaging using NIR fluorophores, this technique further serves as a bridge between in vitro spectroscopic characterization of new fluorophore lifetimes and in vivo tissue imaging. © 2012 The Author Journal of Microscopy © 2012 Royal Microscopical Society.

  8. MR imaging signal enhancement of normal intracranial and extracranial structures

    Muraki, A.S.; Carvlin, M.J.; Francisco, J.; Rocklage, S.M.; Quay, S.

    1988-01-01

    The authors report their initial experience using a paramagnetic manganese chelate complex as a contrast agent for magnetic resonance (MR) imaging of the central nervous system. Five female cats weighing 2-4 kg were used, and anesthesia was induced and maintained with intravenous nembutal (15-25 mg/kg). This contrast agent, manganese (II) N, N'-bis(pyridoxal-5-phosphate) ethylenediamine-N,N'-diacetic acid, or Mn(DPDP)(Salutar), has previously shown efficacy for MR imaging of the hepatobiliary axis but has not been employed in neuroradiologic imaging. T1-weighted (repetition time, 400 msec, echo time, 15, 26 msec; 4-mm sections) spin-echo images were acquired before and after intravenous administration (100 μmol/kg) of the contrast agent. On post-contrast images, the pituitary gland, infundibulum and portohypophyseal system of the hypothalamus and choroid lexus demonstrated signal increase at t=0-30 minutes after injection

  9. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Johnson, Joyce T. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Robinson, Joshua D. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Deng, Jie [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Rigsby, Cynthia K. [Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States)

    2016-12-15

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  10. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Johnson, Joyce T.; Robinson, Joshua D.; Deng, Jie; Rigsby, Cynthia K.

    2016-01-01

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  11. Amphetamines and pH-shift agents for brain imaging

    Biersack, H.J.; Winkler, C.

    1986-01-01

    This book gives a review of the results of experimental and clinical research on both I-amphetamine derivatives and pH-shift agents. Virtually all relevant working groups from the USA and Europe have contributed to this volume. The pharmacology of amphetamine and the corresponding receptor theories are described in detail, whereas other chapters deal with the labeling as well as the metabolic process of this drug. In addition to this, new amphetamine derivatives are presented together with other essential products which play a significant role in scintigraphy of the brain function. Finally, there are two chapters on instrumentation problems followed by eight contributions on the clinical results of amphetamine scintigraphy in cerebral vascular diseases, epilepsy, migraine and brain tumors.

  12. Towards a framework for agent-based image analysis of remote-sensing data.

    Hofmann, Peter; Lettmayer, Paul; Blaschke, Thomas; Belgiu, Mariana; Wegenkittl, Stefan; Graf, Roland; Lampoltshammer, Thomas Josef; Andrejchenko, Vera

    2015-04-03

    Object-based image analysis (OBIA) as a paradigm for analysing remotely sensed image data has in many cases led to spatially and thematically improved classification results in comparison to pixel-based approaches. Nevertheless, robust and transferable object-based solutions for automated image analysis capable of analysing sets of images or even large image archives without any human interaction are still rare. A major reason for this lack of robustness and transferability is the high complexity of image contents: Especially in very high resolution (VHR) remote-sensing data with varying imaging conditions or sensor characteristics, the variability of the objects' properties in these varying images is hardly predictable. The work described in this article builds on so-called rule sets. While earlier work has demonstrated that OBIA rule sets bear a high potential of transferability, they need to be adapted manually, or classification results need to be adjusted manually in a post-processing step. In order to automate these adaptation and adjustment procedures, we investigate the coupling, extension and integration of OBIA with the agent-based paradigm, which is exhaustively investigated in software engineering. The aims of such integration are (a) autonomously adapting rule sets and (b) image objects that can adopt and adjust themselves according to different imaging conditions and sensor characteristics. This article focuses on self-adapting image objects and therefore introduces a framework for agent-based image analysis (ABIA).

  13. Fluorine-18 nuclide and its PET imaging agent

    Wang Mingfang

    2003-01-01

    Fluorine-18 has predominant physical features with long half-life and the enough time for preparation of radiopharmaceuticals and PET imaging. Also, the chemical nature of fluorine-18 is similar to that of hydrogen, and the fluorine-18 labelled organic molecules can not change the non-labelled molecular character. Therefore, fluorine-18 is widely applied in the labelled glucose, amino acids, fatty acids, nucleotide, receptor-ligand and neurotransmitter molecular etc., with the propose of detecting the blood flow, metabolism, synthesis of the protein and the neurotransmitter function in brain by PET imaging. It is very important in the basic science and clinical research to understand and master the preparation of the fluorine-18 and its labelled compounds

  14. Percutaneous cholecystocentesis in cats with suspected hepatobiliary disease.

    Byfield, Victoria L; Callahan Clark, Julie E; Turek, Bradley J; Bradley, Charles W; Rondeau, Mark P

    2017-12-01

    Objectives The objective was to evaluate the safety and diagnostic utility of percutaneous ultrasound-guided cholecystocentesis (PUC) in cats with suspected hepatobiliary disease. Methods Medical records of 83 cats with suspected hepatobiliary disease that underwent PUC were retrospectively reviewed. Results At the time of PUC, at least one additional procedure was performed in 79/83 cats, including hepatic aspiration and/or biopsy (n = 75) and splenic aspiration (n = 18). Complications were noted in 14/83 cases, including increased abdominal fluid (n = 11), needle-tip occlusion (n = 1), failed first attempt to penetrate the gall bladder wall (n = 1) and pneumoperitoneum (n = 1). There were no reports of gall bladder rupture, bile peritonitis or hypotension necessitating treatment with vasopressor medication. Blood products were administered to 7/83 (8%) cats. Seventy-two cats (87%) survived to discharge. Of the cats that were euthanized (9/83) or died (2/83), none were reported as a definitive consequence of PUC. Bacteria were identified cytologically in 10/71 samples (14%); all 10 had a positive aerobic bacterial culture. Bile culture was positive in 11/80 samples (14%). Of the cases with a positive bile culture, cytological description of bacteria corresponded to the organism cultured in fewer than 50% of cases. The most common cytologic diagnosis was hepatic lipidosis (49/66). The most common histopathologic diagnosis was cholangitis (10/21). Conclusions and relevance PUC was safe in this group of cats with suspected hepatobiliary disease. Complications were likely associated with ancillary procedures performed at the time of PUC. Bile analysis yielded an abnormal result in nearly one-third of cats with suspected hepatobiliary disease. Complete agreement between bile cytology and culture was lacking. Further evaluation of the correlation between bile cytology and bile culture is warranted.

  15. Elemental imaging of MRI contrast agents: benchmarking of LA-ICP-MS to MRI

    Pugh, J.A.T. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); University of Sheffield, Department of Chemical and Biological Engineering, Sheffield (United Kingdom); Cox, A.G.; McLeod, C.W. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); Bunch, J. [University of Birmingham, School of Chemistry, Birmingham (United Kingdom); Writer, M.J.; Hart, S.L. [UCL Institute of Child Health, Wolfson Centre for Gene Therapy of Childhood Disease, London (United Kingdom); Bienemann, A.; White, E. [University of Bristol, School of Clinical Sciences, Southmead Hospital, Bristol (United Kingdom); Bell, J. [Hammersmith Hospital, Metabolic and Molecular Imaging Group, MRC Clinical Sciences Centre, Imperial College London, London (United Kingdom)

    2012-06-15

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been used to map the spatial distribution of magnetic resonance imaging (MRI) contrast agents (Gd-based) in histological sections in order to explore synergies with in vivo MRI. Images from respective techniques are presented for two separate studies namely (1) convection enhanced delivery of a Gd nanocomplex (developmental therapeutic) into rat brain and (2) convection enhanced delivery, with co-infusion of Magnevist (commercial Gd contrast agent) and Carboplatin (chemotherapy drug), into pig brain. The LA technique was shown to be a powerful compliment to MRI not only in offering improved sensitivity, spatial resolution and signal quantitation but also in giving added value regarding the fate of administered agents (Gd and Pt agents). Furthermore simultaneous measurement of Fe enabled assignment of an anomalous contrast enhancement region in rat brain to haemorrhage at the infusion site. (orig.)

  16. Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

    Beitzke, Dietrich; Wolf, Florian; Juelg, Gregor; Lammer, Johannes; Loewe, Christian

    2011-01-01

    Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

  17. Progress of study on the dopamine D4 receptor imaging agent

    Tian Haibin; Zhang Lan; Zhang Chunfu; Li Junling; Yin Duanzhi

    2001-01-01

    Dopamine receptors were originally classified into five receptors subtypes, the dopamine D 4 receptor was included. Schizophrenic pathophysiology may be associated with expression and function of the dopamine D 4 receptor; it is of great importance to study the imaging agent of dopamine D 4 receptor. The study on radioactivity distribution and metabolize of radioligand remains hampered by the lack radioligand for the D 4 receptor which can be labeled using suitable nuclei. This paper reviews the progress of study on the dopamine D 4 receptor imaging agent, with particular emphasis vary nuclei, for example 11 C, 18 F, 123 I, labeled D 4 receptor ligands, antagonists and analogs as PET or SPECT imaging agents. Authors estimated affinity and selectivity of radioligands for the dopamine D 4 receptor in laboratory animal tests

  18. Gd-DTPA as a paramagnetic contrast agent in MR imaging of focal liver lesions

    Hamm, B.; Roemer, T.; Wolf, K.J.; Felix, R.; Weinmann, H.J.

    1986-01-01

    Gd-DTPA enhances signal intensity in healthy liver and in intrahepatic tumors. However, after contrast agent administration, tumor enhances significantly more than liver parenchyma (2α≤ 0.05). Doubling the dose of Gd-DTPA from 0.1 to 0.2 mmol/kg of body weight increases the enhancement of intrahepatic tumors (2α≤ 0.05) and optimizes the contrast between tumor and liver in T1-weighted spin-echo sequences. However, the contrast between tumor and liver on inversion-recovery and T2-weighted images obtained before contrast agent administration is much greater than the difference on T1-weighted images obtained after contrast agent administration (2α≤ 0.05). In fast images the contrast between liver and tumor can be markedly improved by administering Gd-DTPA

  19. Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

    Xi Yan; Zhao Jun; Tang Rongbiao; Wang Yujie

    2011-01-01

    In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

  20. Diethylenetriaminepentaacetic acid-gadolinium (DTPA-Gd)-conjugated polysuccinimide derivatives as magnetic resonance imaging contrast agents.

    Lee, Ha Young; Jee, Hye Won; Seo, Sung Mi; Kwak, Byung Kook; Khang, Gilson; Cho, Sun Hang

    2006-01-01

    Biocompatible polysuccinimide (PSI) derivatives conjugated with diethylenetriaminepentaacetic acid gadolinium (DTPA-Gd) were prepared as magnetic resonance imaging (MRI) contrast agents. In this study, we synthesized PSI derivatives incorporating methoxy-poly(ethylene glycol) (mPEG) as hydrophilic ligand, hexadecylamine as hydrophobic ligand, and DTPA-Gd as contrast agent. PSI was synthesized by the polycondensation polymerization of aspartic acid. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR). Critical micellization concentrations were determined using fluorescent probes (pyrene). Micelle size and shape were measured by electro-photometer light scattering (ELS) and atomic force microscopy (AFM). The formed micelle size ranged from 100 to 300 nm. The T1-weighted MR images of the phantom prepared with PSI-mPEG-C16-(DTPA-Gd) were obtained in a 3.0 T clinical MR imager, and the conjugates showed a great potential as MRI contrast agents.

  1. Bimodal MR-PET agent for quantitative pH imaging

    Frullano, Luca; Catana, Ciprian; Benner, Thomas; Sherry, A. Dean; Caravan, Peter

    2010-01-01

    Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on relaxivity and agent concentration – two unknowns. A bimodal approach, incorporating a positron emitter, solves this problem. Simultaneous positron emission tomography (PET) and MR imaging with the biomodal, pH-responsive MR-PET agent GdDOTA-4AMP-F allows direct determination of both concentration (PET) and T1 (MRI), and hence pH. PMID:20191650

  2. Submicron polycaprolactone particles as a carrier for imaging contrast agent for in vitro applications.

    Iqbal, Muhammad; Robin, Sophie; Humbert, Philippe; Viennet, Céline; Agusti, Geraldine; Fessi, Hatem; Elaissari, Abdelhamid

    2015-12-01

    Fluorescent materials have recently attracted considerable attention due to their unique properties and high performance as imaging agent in biomedical fields. Different imaging agents have been encapsulated in order to restrict its delivery to a specific area. In this study, a fluorescent contrast agent was encapsulated for in vitro application by polycaprolactone (PCL) polymer. The encapsulation was performed using modified double emulsion solvent evaporation technique with sonication. Fluorescent nanoparticles (20 nm) were incorporated in the inner aqueous phase of double emulsion. A number of samples were fabricated using different concentrations of fluorescent contrast agent. The contrast agent-containing submicron particle was characterized by a zetasizer for average particle size, SEM and TEM for morphology observations and fluorescence spectrophotometer for encapsulation efficiency. Moreover, contrast agent distribution in the PCL matrix was determined by confocal microscopy. The incorporation of contrast agent in different concentrations did not affect the physicochemical properties of PCL particles and the average size of encapsulated particles was found to be in the submicron range. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Mechanistic and quantitative insight into cell surface targeted molecular imaging agent design.

    Zhang, Liang; Bhatnagar, Sumit; Deschenes, Emily; Thurber, Greg M

    2016-05-05

    Molecular imaging agent design involves simultaneously optimizing multiple probe properties. While several desired characteristics are straightforward, including high affinity and low non-specific background signal, in practice there are quantitative trade-offs between these properties. These include plasma clearance, where fast clearance lowers background signal but can reduce target uptake, and binding, where high affinity compounds sometimes suffer from lower stability or increased non-specific interactions. Further complicating probe development, many of the optimal parameters vary depending on both target tissue and imaging agent properties, making empirical approaches or previous experience difficult to translate. Here, we focus on low molecular weight compounds targeting extracellular receptors, which have some of the highest contrast values for imaging agents. We use a mechanistic approach to provide a quantitative framework for weighing trade-offs between molecules. Our results show that specific target uptake is well-described by quantitative simulations for a variety of targeting agents, whereas non-specific background signal is more difficult to predict. Two in vitro experimental methods for estimating background signal in vivo are compared - non-specific cellular uptake and plasma protein binding. Together, these data provide a quantitative method to guide probe design and focus animal work for more cost-effective and time-efficient development of molecular imaging agents.

  4. The use contrast agent for imaging biological samples

    Dammer, J.; Weyda, František; Sopko, V.; Jakůbek, J.

    2011-01-01

    Roč. 6, C01096 (2011), s. 1-7 ISSN 1748-0221. [International Workshop on Radiation Imaging Detectors /12./. Cambridge, 11.07.2010-15.7.2010] R&D Projects: GA MŠk 2B06005 Grant - others:Research Program(CZ) 6840770029; Research Program(CZ) 6840770040; GA AV ČR(CZ) IAA600550614; GA MŠk(CZ) 2B06007; GA MŠk(CZ) 1PO4LA211; GA MŠk(CZ) LC06041 Program:IA; 2B; LC Institutional research plan: CEZ:AV0Z50070508 Keywords : x-ray radiography and digital radiography (DR) * x-ray detectors * inspections with x-rays Subject RIV: EA - Cell Biology Impact factor: 1.869, year: 2011

  5. Study of new 113mIn-BAT complexes for myocardial imaging agents

    Zhu Lin; Liu Boli; Kojima, M.

    1991-01-01

    Some new BAT derivatives are designed and synthesized in order to find some ideal myocardial imaging agents. These ligands form pentacoordinated complexes with indium cation. The structures of ligand BAT-TE and complexes In-BAT-TE and In-BAT-ETE are determined by X-ray crystallography at first. Biodistribution shows that the higher lipophilicity of complex induces apparently higher myocardial accumulation. Up to date, complex B is the best 113m In-labeled myocardial imaging agent. It is also suited to 111 In

  6. Development of Tc-99m labeled myocardial imaging agent

    Jeong, J. M.; Jang, Y. S.; Kim, Y. J.; Lee, Y. S.; Kim, H. W.; Ray, G.; Lee, M. S.

    2006-02-01

    Lipophilic cations have been widely used for myocardial SPECT. We synthesized novel +1 charged lipophilic Tc-99m-labeled N,N'-disubstituted N2S2 derivatives and investigated their biodistribution. The N,N'-dimethyl-, N,N'-diethyl-, N,N'-bis(methoxyethyl)-, and N,N'-bis(ethoxyethyl)N2S2 derivatives were synthesized by alkylating disulfide form of N2S2 with corresponding alkyl halides and subsequently reduced with LAH in THF. To label with Tc-99m, 50% gluconic acid (0.1 ml), SnCl2·2H2O (10 μg), Tc-99m-pertechnetate (370 MBq/2.5 ml) and 0.5 M Na2CO3 (0.3 ml) were added to the compounds. These mixtures were reacted in boiling water bath for 30∼60 min. Radiochemical purities were checked by Whatman No.1 chromatography (normal saline, Rf 0.3∼0.4). Biodistribution of each compound was investigated after injecting 74 kBq (0.1 ml) of each Tc-99m-labeled compound to ICR-mice through the tail vein. Chemical structures of synthesized compounds were confirmed by GC-MSD and 1H-NMR spectroscopy. All of the Tc-99m-labeled compound showed labeling efficiencies of higher than 93%. In biodistribution study, the myocardial uptake of Tc-99m-N,N'-dimethylN2S2, Tc-99m-N,N'-diethylN2S2, Tc-99m-N,N'-bis(methoxyethyl)N2S2 and Tc-99m-N,N'-bis(ethoxyethyl)N2S2 were 5.38 ±0.96, 2.98 ±0.16, 4.27 ±0.47, 7.24 ±1.01% ID/g at 10 min and 5.34 ±1.57, 2.05 ±0.40, 1.02 ±0.16, 1.69 ±0.04% ID/g at 2 hr, respectively. We successfully synthesized Tc-99m-labeled N,N-disubstituted N2S2 derivatives that are novel lipophilic +1 charged compounds. We thought our results prove the feasibility of these compounds to use for myocardial SPECT agent

  7. Comparison of positive and negative enteral contrast agents for MR imaging of the abdomen

    Kaminsky, S.; Langer, M.

    1994-01-01

    Following oral administration of a buffered gadopentetate-dimeglumine solution (Magnevist enteral R , 1 mmol/l, 6-17 ml/kg) T 1 -, proton-density- and T 2 -weighted spin-echo images of abdominal and retroperitoneal lesions were acquired (0.5 T). Gadopentetate is a signal-enhancing, positive MR contrast agent, intraluminar air served as a model of a signal-free, negative agent. In 21 patients contrast/noise ratios of gadopentetate and air versus lesions and fat were compared quantitatively (t-test). In T 1 - and T 2 -weighted images contrast/noise ratios of gadopentetate versus lesions were significantly higher than those of air. In proton-density images there was no significant difference. In T 1 - and proton-density images contrast/noise ratios of air versus abdominal fat were significantly higher than those of gadopentetate, in T 2 -weighted images gadopentetate had a significantly higher contrast/noise ratio than air. Signal-enhancing positive contrast agents seem advantageous over signal-free negative enteral MR contrast agents. (orig.) [de

  8. Gadolinium-porphyrins: new potential magnetic resonance imaging contrast agents for melanoma detection

    Daryoush Shahbazi-Gahrouei

    2006-11-01

    Full Text Available BACKGROUND: Two new porphyrin-based magnetic resonance imaging (MRI contrast agents, Gd-hematoporphyrin (Gd-H and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP were synthesized and tested in nude mice with human melanoma (MM-138 xenografts as new melanoma contrast agents. METHODS: Subcutaneous xenografts of human melanoma cells (MM-138 were studied in 30 (five groups of six nude mice. The effect of different contrast agents (Gd-TCP, Gd-H, GdCl3 and Gd-DTPA on proton relaxation times was measured in tumors and other organs. T1 values, signal enhancement and the Gd concentration for different contrast agent solutions were also investigated. RESULTS: The porphyrin agents showed higher relaxivity compared to the clincal agent, Gd-DTPA. A significant 16% and 21% modification in T1 relaxation time of the water in human melanoma tumors grafted in the nude mice was revealed 24 hours after injection of Gd-TCP and Gd-H, respectively. The percentage of injected Gd localized to the tumor measured by inductively coupled plasma atomic emission spectrometry (ICP-AES was approximately 21% for Gd-TCP and 28% for Gd-H which were higher than that of Gd-DTPA (10%. CONCLUSIONS: The high concentration of Gd in the tumor is indicative of a selective retention of the compounds and indicates that Gd-TCP and Gd-H are promising MR imaging contrast agents for melanoma detection. Gd-porphyrins have considerable promise for further diagnostic applications in magnetic resonance imaging. KEY WORDS: MRI, porphyrin-based contrast agent, hematoporphyrin, melanoma.

  9. Analogues of estradiol as potential breast tumor imaging agents

    Gibson, R.E.; Rzeszotarski, W.J.; Ferriera, N.L.; Jagoda, E.M.; Reba, R.C.; Eckelman, W.C.

    1984-01-01

    The radioiodinated analogue of estradiol, 11β-methoxy-17α-[/sup 125/I]iodovinylestradiol (MIVE/sub 2/), has been shown to be a good candidate for the imaging of estrogen dependent breast tumors. Although there has been no extensive study on the sensitivity of radiotracers of this type, the authors have not observed localization of the radiotracer in metastatic lesions containing less than 20 fmole estrogen receptor/mg protein or in bone metasteses. In order to improve the sensitivity, they have examined several structural analogues of moxestrol (the parent structure for MIVE/sub 2/) for affinity to the ER isolated from immature rat uterus. The 11β-ethyl analogue (EEE/sub 2/) of ethynyl estradiol (EE/sub 2/) exhibits the highest affinity with the 11β-methyl analogue second best. Although the lipophilicity is also very high this compound should not be much more lipophilic than 16-iodoestradiol or MIVE/sub 2/ since the introduction of iodine increases the log P by greater than 1. The distribution of the tritiated derivative of EEE/sub 2/ is under study

  10. Studies on polyaspartamide gadolinium complexes as potential magnetic resonance imaging contrast agents

    Yan Guoping; Liu Maili; Li Liyun

    2005-01-01

    Purpose: A series of polyaspartamide gadolinium complexes containing pyridoxamine groups were studied as the potential magnetic resonance imaging (MRI) contrast agents for liver enhancement. Methods: These polyaspartamide gadolinium complexes were prepared and evaluated by relaxivity, acute toxicity studies and magnetic resonance imaging of the liver in rats. Results: These polyaspartamide gadolinium complexes have higher relaxation effectiveness than that of the clinically used gadolinium diethylenetriaminepentaacetic acid and possess the low intravenous acute toxicities to Institute for Cancer Research (ICR) mice. Magnetic resonance imaging of the liver in rats indicated that they greatly enhance the contrast of magnetic resonance images and provide prolonged intravascular duration in the liver. Conclusion: These results indicated that the polyaspartamide gadolinium complexes containing pyridoxamine groups could be considered as the appropriate MRI contrast agents for liver enhancement

  11. Imaging efficiency of an X-ray contrast agent-incorporated polymeric microparticle.

    Ahn, Sungsook; Jung, Sung Yong; Lee, Jin Pyung; Lee, Sang Joon

    2011-01-01

    Biocompatible polymeric encapsulants have been widely used as a delivery vehicle for a variety of drugs and imaging agents. In this study, X-ray contrast agent (iopamidol) is encapsulated into a polymeric microparticle (polyvinyl alcohol) as a particulate flow tracer in synchrotron X-ray imaging system. The physical properties of the designed microparticles are investigated and correlated with enhancement in the imaging efficiency by experimental observation and theoretical interpretation. The X-ray absorption ability of the designed microparticle is assessed by Beer-Lambert-Bouguer law. Particle size, either in dried state or in solvent, primarily dominates the X-ray absorption ability under the given condition, thus affecting imaging efficiency of the designed X-ray contrast flow tracers. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside

    Croisille, Pierre; Revel, Didier; Saeed, Maythem

    2006-01-01

    This review paper presents, in the first part, the different classes of contrast media that are already used or are in development for cardiac magnetic resonance imaging. A classification of the different types of contrast media is proposed based on the distribution of the compounds in the body, their type of relaxivity and their potential affinity to particular molecules. In the second part, the different uses of the extracellular type of T1-enhancing contrast agent for myocardial imaging is covered from the detection of stable coronary artery disease to the detection and characterization of chronic infarction. A particular emphasis is placed on the clinical use of gadolinium-chelates, which are the universally used type of MRI contrast agent in the clinical routine. Both approaches, first-pass magnetic resonance imaging (FP-MRI) as well as delayed-enhanced magnetic resonance imaging (DE-MRI), are covered in the different situations of acute and chronic myocardial infarction. (orig.)

  13. Cholangiocarcinoma in Cirrhosis: Value of Hepatocyte Specific Magnetic Resonance Imaging.

    Piscaglia, Fabio; Iavarone, Massimo; Galassi, Marzia; Vavassori, Sara; Renzulli, Matteo; Forzenigo, Laura Virginia; Granito, Alessandro; Salvatore, Veronica; Sangiovanni, Angelo; Golfieri, Rita; Colombo, Massimo; Bolondi, Luigi

    2015-10-01

    The diagnosis of intrahepatic cholangiocellular carcinoma (ICC) remains elusive at imaging, which is a critical issue in cirrhotic patients in whom a diagnosis of hepatocellular carcinoma (HCC) can be established only by imaging. The aim of the study was to evaluate the potential of MRI in the diagnosis of ICC in cirrhosis using 'hepatocyte-specific' Gadolinium (Gd)-based contrast agents. Sixteen histologically proven and retrospectively identified ICCs on cirrhosis were investigated with hepatocyte-specific magnetic resonance contrast agents (6 in Bologna with Gd-EOB-DTPA and 10 in Milan with Gd-BOPTA). The control group consisted of 41 consecutively and prospectively collected nodules (31 HCCs) imaged with Gd-EOB-DTPA. Fifteen ICC nodules (94%) displayed hypointensity in the hepatobiliary phase, suggesting malignancy. Thirteen cholangiocarcinomas (81%) showed hyperenhancement in the venous phase. Only 2 cholangiocarcinoma nodules showed hypoenhancement in the venous phase, corresponding to washout, in both cases preceded by rim enhancement in arterial phase. All the hepatocarcinomas showed hypointensity in hepatobiliary phase, but was always preceded by hypointensity in the venous phase; arterial rim enhancement was never observed in any hepatocarcinoma or regenerative nodule. MRI with hepatocyte-specific Gd-based contrast agents showed a pattern of malignancy in almost all the ICCs, concurrently avoiding misdiagnosis with hepatocarcinoma. These findings suggest a greater diagnostic capacity for this technique compared with the results of MRI with conventional contrast agents reported in the literature in this setting. © 2015 S. Karger AG, Basel.

  14. Assessment of myocardial infarction by magnetic resonance imaging with the aid of contrast agents

    Roos, A. de; Doornbos, J.

    1991-01-01

    The potential of MR imaging in myocardial ischemia with low-temporal-resolution spin-echo techniques both with and without MR contrast agents has been explored. There are indications that early MR imaging after administration of Gd-DTPA is capable to differentiate reperfused from non-reperfused infarcts. Furthermore, MR infarct sizing using Gd-DTPA is feasible to demonstrate infarct size reduction in patients with successful reperfusion. (H.W.). 50 refs.; 9 figs

  15. Renal perfusion image using harmonic ultrasound with microbble contrast agent: preliminary study

    Kim, Jung Hoon; Choi, Jae Ho; Han, Dong Chul; Lee, Hi Bahl; Choi, Deuk Lin; Eun, Hyo Won; Lee, Hun Jae

    2003-01-01

    To compare, in terms of their feasibility and normal range, 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic ultrasound (US) with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation. During a six-month period, thirty patients who had received a renal transplant underwent both 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic US with a microbubble contrast agent. Sonographic renal perfusion images were obtained before and after a bolus injection of the microbubble contrast agent Levovist TM (SH U 5084; Schering AG, Berlin, Germany) every 3 seconds for 3 minutes. Sonographic renal perfusion images were converted into a renal perfusion curve by a computer program and T peak of the curve thus obtained was compared with that of the 99m Tc-DTPA curve. Average T peak of the 99m Tc-DTPA renal perfusion curve was 16.2 seconds in the normal group and 39.6 seconds in the delayed perfusion group, while average T peak of the sonographic renal perfusion curve was 23.7 seconds and 46.2 seconds, respectively. T peak of the sonographic renal perfusion curve showed a good correlation with that of the 99m Tc-DTPA curve (correlation coefficient=0.8209; p=0.0001). The cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds (sensitivity=90%, specificity=95%). In patients who have received a renal transplant, the findings of renal perfusion imaging using harmonic US with a microbubble contrast agent show close correlation with those of 99m Tc-DTPA renal perfusion imaging. The optimal cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds

  16. Examining multi-component DNA-templated nanostructures as imaging agents

    Jaganathan, Hamsa

    2011-12-01

    Magnetic resonance imaging (MRI) is the leading non-invasive tool for disease imaging and diagnosis. Although MRI exhibits high spatial resolution for anatomical features, the contrast resolution is low. Imaging agents serve as an aid to distinguish different types of tissues within images. Gadolinium chelates, which are considered first generation designs, can be toxic to health, while ultra-small, superparamagnetic nanoparticles (NPs) have low tissue-targeting efficiency and rapid bio-distribution, resulting to an inadequate detection of the MRI signal and enhancement of image contrast. In order to improve the utility of MRI agents, the challenge in composition and structure needs to be addressed. One-dimensional (1D), superparamagnetic nanostructures have been reported to enhance magnetic and in vivo properties and therefore has a potential to improve contrast enhancement in MRI images. In this dissertation, the structure of 1D, multi-component NP chains, scaffolded on DNA, were pre-clinically examined as potential MRI agents. First, research was focused on characterizing and understanding the mechanism of proton relaxation for DNA-templated NP chains using nuclear magnetic resonance (NMR) spectrometry. Proton relaxation and transverse relaxivity were higher in multi-component NP chains compared to disperse NPs, indicating the arrangement of NPs on a 1D structure improved proton relaxation sensitivity. Second, in vitro evaluation for potential issues in toxicity and contrast efficiency in tissue environments using a 3 Tesla clinical MRI scanner was performed. Cell uptake of DNA-templated NP chains was enhanced after encapsulating the nanostructure with layers of polyelectrolytes and targeting ligands. Compared to dispersed NPs, DNA-templated NP chains improved MRI contrast in both the epithelial basement membrane and colon cancer tumors scaffolds. The last part of the project was focused on developing a novel MRI agent that detects changes in DNA methylation

  17. Synchrotron-based DEI for bio-imaging and DEI-CT to image phantoms with contrast agents

    Rao, Donepudi V.; Swapna, Medasani; Cesareo, Roberto; Brunetti, Antonio; Akatsuka, Tako; Yuasa, Tetsuya; Zhong, Zhong; Takeda, Tohoru; Gigante, Giovanni E.

    2012-01-01

    The introduction of water, physiological, or iodine as contrast agents is shown to enhance minute image features in synchrotron-based X-ray diffraction radiographic and tomographic imaging. Anatomical features of rat kidney, such as papillary ducts, ureter, renal artery and renal vein are clearly distinguishable. Olfactory bulb, olfactory tact, and descending bundles of the rat brain are visible with improved contrast. - Highlights: ► Distinguishable anatomical structures features of rat kidney and rat brain are acquired with Sy-DEI in planar mode. ► Images of a small brain phantom and cylindrical phantom are acquired in tomography mode (Sy-DEI-CT) with contrast agents. ► Sy-DEI and Sy-DEI-CT techniques provide new source of information related to biological microanatomy.

  18. The analytical of radiochemical purity of tumor receptor imaging agent 99Tcm-octreotide

    Wang Xufu; Zuo Shuyao; Shao Wenbo; Wang Guoming; Sun Jianwen; Zhang Qin

    2003-01-01

    The radiochemical purity of tumor receptor imaging agent 99 Tc m -octreotide is measured by High Pressure Liquid Chromatography (HPLC) and two systems of chromatography combining method of silver stain. The results show that the radiochemical purity of 98 Tc m -octreotide measured by both methods are effective and correct. It can separate 99 Tc m -octreotide from other radioactive compositions correctly and effectively

  19. Identification of a Common Binding Mode for Imaging Agents to Amyloid Fibrils from Molecular Dynamics Simulations

    Skeby, Katrine Kirkeby; Sørensen, Jesper; Schiøtt, Birgit

    2013-01-01

    experimentally due to the insoluble nature of amyloid fibrils. This study uses molecular dynamics simulations to investigate the interactions between 13 aromatic amyloid imaging agents, entailing 4 different organic scaffolds, and a model of an amyloid fibril. Clustering analysis combined with free energy...

  20. Zirconia-doped nanoparticles: organic coating, polymeric entrapment and application as dual-imaging agents

    Rebuttini, Valentina; Pucci, Andrea; Arosio, Paolo; Bai, Xue; Locatelli, Erica; Pinna, Nicola; Lascialfari, Alessandro; Franchini, Mauro Comes

    2013-01-01

    Zirconia nanoparticles doped with Eu3+, Tb3+ and Gd3+ ions have been synthesized following the benzyl alcohol route. The nanoparticles were coated with N-hydroxydodecanamide and encapsulated in PLGA-b-PEG-COOH nanomicelles. The magnetic and fluorescent properties of these hybrid nanocarriers were investigated, proving them to be potential dual-imaging contrast agents.

  1. A theranostic agent to enhance osteogenic and magnetic resonance imaging properties of calcium phosphate cements

    Ventura, M.; Sun, Y.; Cremers, S.; Borm, P.; Tahmasebi Birgani, Zeinab; Habibovic, Pamela; Heerschap, A.; van der Kraan, P.M.; Jansen, J.A.; Walboomers, X.F.

    2014-01-01

    With biomimetic biomaterials, like calcium phosphate cements (CPCs), non-invasive assessment of tissue regeneration is challenging. This study describes a theranostic agent (TA) to simultaneously enhance both imaging and osteogenic properties of such a bone substitute material. For this purpose,

  2. Synthesis and evaluation of three iodinated haloperidol derivatives as potential dopamine receptor imaging agents

    Hunter, D.H.; Strickland, L.A.; Zabel, P.L.

    1990-01-01

    Haloperidol, a neuroleptic which shows D-2 receptor affinity and selectivity, has been labelled primarily with positron emitting isotopes. The authors have synthesized three iodinated analogues of Haloperidol to investigate the possibility of an iodine-123 labelled agent for SPECT imaging. These compounds were obtained from the substitution of halogenated butyrophenones by halogenated arylpiperidols. In vitro and in vivo experiments will be discussed

  3. Amphetamines and pH-shift agents for brain imaging: Basic research and clinical results

    Biersack, H.J.; Winkler, C.

    1986-01-01

    This book contains 18 selections. Some of the titles are: Labelling of amphetamines with /sup 123/I: Receptors for amphetamines; New amphetamine derivatives; Potential new approaches for the development of brain imaging agents for single-photon applications; and IM SPECT with the pinhole collimator.

  4. RGD-based strategies for selective delivery of therapeutics and imaging agents to the tumour vasculature

    Temming, K; Molema, G; Kok, RJ

    2005-01-01

    During the past decade, RGD-peptides have become a popular tool for the targeting of drugs and imaging agents to a(v)beta(3)-integrin expressing tumour vasculature. RGD-peptides have been introduced by recombinant means into therapeutic proteins and viruses. Chemical means have been applied to

  5. NaGdF4:Nd3+/Yb3+ Nanoparticles as Multimodal Imaging Agents

    Pedraza, Francisco; Rightsell, Chris; Kumar, Ga; Giuliani, Jason; Monton, Car; Sardar, Dhiraj

    Medical imaging is a fundamental tool used for the diagnosis of numerous ailments. Each imaging modality has unique advantages; however, they possess intrinsic limitations. Some of which include low spatial resolution, sensitivity, penetration depth, and radiation damage. To circumvent this problem, the combination of imaging modalities, or multimodal imaging, has been proposed, such as Near Infrared Fluorescence imaging (NIRF) and Magnetic Resonance Imaging (MRI). Combining individual advantages, specificity and selectivity of NIRF with the deep penetration and high spatial resolution of MRI, it is possible to circumvent their shortcomings for a more robust imaging technique. In addition, both imaging modalities are very safe and minimally invasive. Fluorescent nanoparticles, such as NaGdF4:Nd3 +/Yb3 +, are excellent candidates for NIRF/MRI multimodal imaging. The dopants, Nd and Yb, absorb and emit within the biological window; where near infrared light is less attenuated by soft tissue. This results in less tissue damage and deeper tissue penetration making it a viable candidate in biological imaging. In addition, the inclusion of Gd results in paramagnetic properties, allowing their use as contrast agents in multimodal imaging. The work presented will include crystallographic results, as well as full optical and magnetic characterization to determine the nanoparticle's viability in multimodal imaging.

  6. Element-specific spectral imaging of multiple contrast agents: a phantom study

    Panta, R. K.; Bell, S. T.; Healy, J. L.; Aamir, R.; Bateman, C. J.; Moghiseh, M.; Butler, A. P. H.; Anderson, N. G.

    2018-02-01

    This work demonstrates the feasibility of simultaneous discrimination of multiple contrast agents based on their element-specific and energy-dependent X-ray attenuation properties using a pre-clinical photon-counting spectral CT. We used a photon-counting based pre-clinical spectral CT scanner with four energy thresholds to measure the X-ray attenuation properties of various concentrations of iodine (9, 18 and 36 mg/ml), gadolinium (2, 4 and 8 mg/ml) and gold (2, 4 and 8 mg/ml) based contrast agents, calcium chloride (140 and 280 mg/ml) and water. We evaluated the spectral imaging performances of different energy threshold schemes between 25 to 82 keV at 118 kVp, based on K-factor and signal-to-noise ratio and ranked them. K-factor was defined as the X-ray attenuation in the K-edge containing energy range divided by the X-ray attenuation in the preceding energy range, expressed as a percentage. We evaluated the effectiveness of the optimised energy selection to discriminate all three contrast agents in a phantom of 33 mm diameter. A photon-counting spectral CT using four energy thresholds of 27, 33, 49 and 81 keV at 118 kVp simultaneously discriminated three contrast agents based on iodine, gadolinium and gold at various concentrations using their K-edge and energy-dependent X-ray attenuation features in a single scan. A ranking method to evaluate spectral imaging performance enabled energy thresholds to be optimised to discriminate iodine, gadolinium and gold contrast agents in a single spectral CT scan. Simultaneous discrimination of multiple contrast agents in a single scan is likely to open up new possibilities of improving the accuracy of disease diagnosis by simultaneously imaging multiple bio-markers each labelled with a nano-contrast agent.

  7. Hsp90 and hepatobiliary transformation during sea lamprey metamorphosis.

    Chung-Davidson, Yu-Wen; Yeh, Chu-Yin; Bussy, Ugo; Li, Ke; Davidson, Peter J; Nanlohy, Kaben G; Brown, C Titus; Whyard, Steven; Li, Weiming

    2015-12-01

    Biliary atresia (BA) is a human infant disease with inflammatory fibrous obstructions in the bile ducts and is the most common cause for pediatric liver transplantation. In contrast, the sea lamprey undergoes developmental BA with transient cholestasis and fibrosis during metamorphosis, but emerges as a fecund adult. Therefore, sea lamprey liver metamorphosis may serve as an etiological model for human BA and provide pivotal information for hepatobiliary transformation and possible therapeutics. We hypothesized that liver metamorphosis in sea lamprey is due to transcriptional reprogramming that dictates cellular remodeling during metamorphosis. We determined global gene expressions in liver at several metamorphic landmark stages by integrating mRNA-Seq and gene ontology analyses, and validated the results with real-time quantitative PCR, histological and immunohistochemical staining. These analyses revealed that gene expressions of protein folding chaperones, membrane transporters and extracellular matrices were altered and shifted during liver metamorphosis. HSP90, important in protein folding and invertebrate metamorphosis, was identified as a candidate key factor during liver metamorphosis in sea lamprey. Blocking HSP90 with geldanamycin facilitated liver metamorphosis and decreased the gene expressions of the rate limiting enzyme for cholesterol biosynthesis, HMGCoA reductase (hmgcr), and bile acid biosynthesis, cyp7a1. Injection of hsp90 siRNA for 4 days altered gene expressions of met, hmgcr, cyp27a1, and slc10a1. Bile acid concentrations were increased while bile duct and gall bladder degeneration was facilitated and synchronized after hsp90 siRNA injection. HSP90 appears to play crucial roles in hepatobiliary transformation during sea lamprey metamorphosis. Sea lamprey is a useful animal model to study postembryonic development and mechanisms for hsp90-induced hepatobiliary transformation.

  8. Biodistribution and micro PET imaging of 18F-FECNT as a dopamine transporter imaging agent

    Chen Zhengping; Wang Songpei; Li Xiaomin; Liu Chunyi; Tang Jie; Lu Chunxiong; Pan Donghui; Xu Yuping; Yang Ming; Jiang Quanfu; Huang Hongbo; Zhou Xingqing

    2009-01-01

    Objective: 2β-carbomethoxy-3β-(4-corophenyl)-8-(2- 18 F-fluoroethyl) nortropane ( 18 F-FECNT) is a recently developed dopamine transporter (DAT) imaging agent. The aim of this study was to evaluate its brain biodistribution and to assess its usefulness in quantitation of DAT density in normal and hemiparkinsonian rats. Methods: Six groups of mice (5 mice each group) received 18 F-FECNT were sacrificed at indicated time post injection. Different brain regions (cortex, hippocampus, striatum, cerebellum) were removed, weighed, and countered. DAT blocking effect was investigated in mice pretreated with 2β-Carbomethoxy-3β-(4-fluorphenyl)tropane (β-CFT) at before 18 F-FECNT injection. MicroPET scans were performed in beth normal and unilaterally 6-hydroxydopamine-lesioned rats. Results: The brain uptake of 18 F-FECNT was 2.22, 1.20, 1.02, 0.78, 0.71, and 0.67 percent injection dose (%ID) at 5, 15, 30, 60, 120, and 180 min post injection. Radioactivity concentration of the striatum, the target region, was the highest in the brain regions and decreased quickly from 5 to 60 min and reached to background at 120 min of post injection. The striatum/cerebellum ratio was 2.56, 3.47, 2.78, 1.63, 0.97, and 0.88 at 5, 15, 30, 60, 120, and 180 min, respectively, post injection. The selective striatum uptake of 1 '8F-FECNT decreased dramatically to the background when the DAT was blocked with β-CFT. The striatum of normal rats in micro-PET exhibited symmetrical (left/right = 1.00 ± 0.05) and the highest uptake of radioactivity (striatum/cerebellum =2.18 ± 0. 16 at 5- 125 min, n =3). As for the hemiparkinsonian rats, nonsymmetrical [unlesioned striatum/cerebellum vs lesioned striatum/cerebellum = 2.01 ± 0.23 (n = 3) vs 1.04 ± 0. 05] and the high-est uptake of radioactivity were also noted. Conclusions: The results suggest that 18 F-FECNT rapidly pas-ses through blood-brain barrier and locates in stiatal region with high affinity and selectivity to DAT. It is a potential

  9. RNA aptamer probes as optical imaging agents for the detection of amyloid plaques.

    Christian T Farrar

    Full Text Available Optical imaging using multiphoton microscopy and whole body near infrared imaging has become a routine part of biomedical research. However, optical imaging methods rely on the availability of either small molecule reporters or genetically encoded fluorescent proteins, which are challenging and time consuming to develop. While directly labeled antibodies can also be used as imaging agents, antibodies are species specific, can typically not be tagged with multiple fluorescent reporters without interfering with target binding, and are bioactive, almost always eliciting a biological response and thereby influencing the process that is being studied. We examined the possibility of developing highly specific and sensitive optical imaging agents using aptamer technology. We developed a fluorescently tagged anti-Aβ RNA aptamer, β55, which binds amyloid plaques in both ex vivo human Alzheimer's disease brain tissue and in vivo APP/PS1 transgenic mice. Diffuse β55 positive halos, attributed to oligomeric Aβ, were observed surrounding the methoxy-XO4 positive plaque cores. Dot blots of synthetic Aβ aggregates provide further evidence that β55 binds both fibrillar and non-fibrillar Aβ. The high binding affinity, the ease of probe development, and the ability to incorporate multiple and multimodal imaging reporters suggest that RNA aptamers may have complementary and perhaps advantageous properties compared to conventional optical imaging probes and reporters.

  10. Molecular Imaging Agents Specific for the Annulus Fibrosus of the Intervertebral Disk

    Summer L. Gibbs-Strauss

    2010-05-01

    Full Text Available Low back pain is a prevalent medical condition that is difficult to diagnose and treat. Current imaging methods are unable to correlate pain reliably with spinal structures, and surgical removal of painful damaged or degenerating disks is technically challenging. A contrast agent specific for the intervertebral disk could assist in the detection, diagnosis, and surgical treatment of low back pain. The styryl pyridinium (FM fluorophores were characterized and structure-activity relationships between chemical structure and in vivo uptake were established. Two novel FM fluorophores with improved optical properties for imaging the intervertebral disks were synthesized and evaluated in mice, rats, and pigs. After a single systemic injection, eight of eight FM fluorophores provided high-contrast imaging of the trigeminal ganglia, whereas six of eight provided high-contrast imaging of the dorsal root ganglia. Unexpectedly, three of eight FM fluorophores provided high-contrast imaging of annulus fibrosus tissue of the intervertebral disks, confirmed histologically. We present the first known contrast agent specific for the intervertebral disks and identify the chemical structural motif that mediates uptake. FM fluorophores could be used for image-guided surgery to assist in the removal of intervertebral disk and lay the foundation for derivatives for magnetic resonance imaging and positron emission tomography.

  11. Experimental studies of the physiologic properties of technetium-99m agents: Myocardial transport of perfusion imaging agents

    Meerdink, D.J.; Leppo, J.A.

    1990-01-01

    The physiologic properties of new technetium-99m-labeled myocardial imaging agents (Tc-99m sestamibi, an isonitrile; and Tc-99m teboroxime, a boronic acid adduct of technetium dioxime) are discussed and compared to thallium-201 (Tl-201). Studies with isolated hearts, subcellular fractions and cell cultures indicate that Tc-99m sestamibi, Tc-99m teboroxime and Tl-201 do not share common transport or sequestration mechanisms. Although peak Tc-99m sestamibi myocardial extraction over time is about half that of Tl-201 at equivalent coronary blood flows, the amount of Tc-99m sestamibi that remains in the heart is similar to that of Tl-201 because of its higher retention efficiency. The high retention efficiency for Tc-99m sestamibi also results in minimal redistribution. In contrast, Tc-99m teboroxime myocardial extraction is higher than that of Tl-201, but its retention is less efficient, resulting in relatively rapid washout characteristics which may quickly result in tracer redistribution. During reperfusion after a no-flow period, Tc-99m sestamibi extraction and retention increase, but for Tc-99m teboroxime and Tl-201 these values tend to decrease. All tracers show adequate transport characteristics for perfusion imaging, and differences in transport and retention should lead to the development of new clinical protocols.27 references

  12. Sporadic incidence of Fascioliasis detected during Hepatobiliary procedures: A study of 18 patients from Sulaimaniyah governorate

    2012-01-01

    Background Fascioliasis is an often-neglected zoonotic disease and currently is an emerging infection in Iraq. Fascioliasis has two distinct phases, an acute phase, exhibiting the hepatic migratory stage of the fluke’s life cycle, and a chronic biliary phase manifested with the presence of the parasite in the bile ducts through hepatic tissue. The incidence of Fascioliasis in Sulaimaniyah governorate was unexpected observation. We believe that shedding light on this disease in our locality will increase our physician awareness and experience in early detection, treatment in order to avoid unnecessary surgeries. Findings We retrospectively evaluated this disease in terms of the demographic features, clinical presentations, and managements by reviewing the medical records of 18 patients, who were admitted to the Sulaimani Teaching Hospital and Kurdistan Centre for Gastroenterology and Hepatology. Patients were complained from hepatobiliary and/or upper gastrointestinal symptoms and diagnosed accidentally with Fascioliasis during hepatobiliary surgeries and ERCP by direct visualization of the flukes and stone analysis. Elevated liver enzymes, white blood cells count and eosinophilia were notable laboratory indices. The dilated CBD, gallstones, liver cysts and abscess were found common in radiological images. Fascioliasis diagnosed during conventional surgical CBD exploration and choledochodoudenostomy, open cholecystectomy, surgical drainage of liver abscess, ERCP and during gallstone analysis. Conclusion Fascioliasis is indeed an emerging disease in our locality, but it is often underestimated and ignored. We recommend the differential diagnosis of patients suffering from Rt. Hypochondrial pain, fever and eosinophilia. The watercress ingestion was a common factor in patient’s history. PMID:23259859

  13. Sporadic incidence of Fascioliasis detected during Hepatobiliary procedures: A study of 18 patients from Sulaimaniyah governorate

    Hawramy Tahir Abdullah Hussein

    2012-12-01

    Full Text Available Abstract Background Fascioliasis is an often-neglected zoonotic disease and currently is an emerging infection in Iraq. Fascioliasis has two distinct phases, an acute phase, exhibiting the hepatic migratory stage of the fluke’s life cycle, and a chronic biliary phase manifested with the presence of the parasite in the bile ducts through hepatic tissue. The incidence of Fascioliasis in Sulaimaniyah governorate was unexpected observation. We believe that shedding light on this disease in our locality will increase our physician awareness and experience in early detection, treatment in order to avoid unnecessary surgeries. Findings We retrospectively evaluated this disease in terms of the demographic features, clinical presentations, and managements by reviewing the medical records of 18 patients, who were admitted to the Sulaimani Teaching Hospital and Kurdistan Centre for Gastroenterology and Hepatology. Patients were complained from hepatobiliary and/or upper gastrointestinal symptoms and diagnosed accidentally with Fascioliasis during hepatobiliary surgeries and ERCP by direct visualization of the flukes and stone analysis. Elevated liver enzymes, white blood cells count and eosinophilia were notable laboratory indices. The dilated CBD, gallstones, liver cysts and abscess were found common in radiological images. Fascioliasis diagnosed during conventional surgical CBD exploration and choledochodoudenostomy, open cholecystectomy, surgical drainage of liver abscess, ERCP and during gallstone analysis. Conclusion Fascioliasis is indeed an emerging disease in our locality, but it is often underestimated and ignored. We recommend the differential diagnosis of patients suffering from Rt. Hypochondrial pain, fever and eosinophilia. The watercress ingestion was a common factor in patient’s history.

  14. 19F labelled dextrans and antibodies as NMR imaging and spectroscopy agents

    Antich, P.P.; Kulkarni, P.V.

    1993-01-01

    A method is described of NMR imaging or spectroscopy, comprising the steps of administering to a living subject a 19 F labelled NMR agent, the NMR agent comprising (a) a transport polymer selected from the group consisting of dextran polymers and amino dextrans, having a molecular weight between approximately 100 d and 500 kd, and antibodies and fragments thereof, and (b) a 19F-containing sensor moiety selected from the group consisting of fluorinated alkyls, fluorinated acetates, fluoroaniline, and fluoroalkyl phosphonates, in an amount effective to provide a detectable NMR signal; and then detecting the 19 F NMR signal produced

  15. Uptake of perfusion imaging agents by transplanted hearts: an experimental study in rats

    Bergsland, J.; Carr, E.A. Jr.; Carroll, M.; Feldman, M.J.; Kung, H.; Wright, J.R.

    1989-01-01

    There is a need for a reliable noninvasive marker of rejection in transplanted hearts. Endomyocardial biopsy is now the universally accepted diagnostic method of choice, but the invasiveness of the procedure and the limited size of the sample obtained makes this method far from ideal. As coronary blood flow may be expected to decrease during acute rejection, there has been interest in thallium-201 chloride (T1), a perfusion marker, as an imaging agent for diagnosing cardiac rejection. Hexakis(t-butylisonitrile)-technetium (Tc-TBI) is a representative of a new class of radiopharmaceuticals proposed as perfusion markers. We have compared the uptake of these imaging agents in a rat model of cardiac transplantation. Uptake of Tc-TBI as well as of T1 was significantly lower in rejecting than in nonrejecting hearts. This change was found in both left (LV) and right (RV) ventricles. Allografts in animals treated with cyclosporine (CyA) showed less severe rejection and higher uptakes of both imaging agents as compared to unmodified rejection. Our results suggest that perfusion imaging with these radionuclides is a potentially useful approach to the problem of detecting allograft rejection

  16. The synthesis of radioiodinated carbohydrates and butyrothenones as potential imaging agents for computed tomography

    Waterhouse, R.N.

    1993-01-01

    Positron Emission tomography (PET) and Single Photon Emission Computed Tomography (SPECT) are two relatively new imaging techniques which allow for the non-invasive evaluation of biochemical processes in living subjects. Currently, SPECT is more widely accessible than PET, however, only a limited number of radiotracers have been successfully developed for imaging by SPECT. Two classes of radioiodinated compounds were developed as potential imaging agents for SPECT: (1) Radioiodinated carbohydrates for the assessment of glucose metabolism and (2) Radioiodinated butyrothienones for the evaluation of dopamine D 2 receptors in the brain. In both classes of compounds, the radioiodine was attached to an sp 2 hybridized carbon atom to provide radiotracers that were chemically and metabolically stable. Radioiodine incorporation was easily accomplished by radioiododestannylation of vinyl- and aryl-trialkylstannanes in the presence of an oxidizing agent. The incorporation of radioiodine into small molecules can have a significant effect on the biological activity of the resulting radiotracer because of the relatively large size and lipophilicity of the iodine atom. Preliminary evaluations of the effectiveness of the radioiodinated carbohydrates and butyrothienones as imaging agents are presented

  17. A naturally occurring contrast agent for OCT imaging of smokers' lung

    Yang Ying; Bagnaninchi, Pierre O; Whiteman, Suzanne C; Pittius, Daniel Gey van; Haj, Alicia J El; Spiteri, Monica A; Wang, Ruikang K

    2005-01-01

    Optical coherence tomography (OCT) offers great potential for clinical applications in terms of its cost, safety and real-time imaging capability. Improvement of its resolution for revealing sub-layers or sub-cellular components within a tissue will further widen its application. In this study we report that carbon pigment, which is frequently present in the lungs of smokers, could be used as a contrast agent to improve the OCT imaging of lung tissue. Carbon produced an intense bright OCT image at a relatively deep location. The parallel histopathological section analysis confirmed the presence of carbon pigment in such tissues. The underlying mechanism of the OCT image formation has been discussed based on a model system in which carbon particles were dispersed in agar gel. Calculations and in-depth intensity profiles of OCT revealed that higher refractive index particles with a size close to or smaller than the wavelength would greatly increase backscattering and generate a sharp contrast, while a particle size several times larger than the wavelength would absorb or obstruct the light path. The naturally occurring contrast agent could provide a diagnostic biomarker of lung tissue in smokers. Furthermore, carbon under such circumstances, can be used as an effective exogenous contrast agent, with which specific components or tissues exhibiting early tumour formation can be optically labelled to delineate the location and boundary, providing potential for early cancer detection and its treatment

  18. A novel nitroreductase-enhanced MRI contrast agent and its potential application in bacterial imaging

    Yun Liu

    2018-05-01

    Full Text Available Nitroreductases (NTRs are known to be able to metabolize nitro-substituted compounds in the presence of reduced nicotinamide adenine dinucleotide (NADH as an electron donor. NTRs are present in a wide range of bacterial genera and, to a lesser extent, in eukaryotes hypoxic tumour cells and tumorous tissues, which makes it an appropriate biomarker for an imaging target to detect the hypoxic status of cancer cells and potential bacterial infections. To evaluate the specific activation level of NTR, great efforts have been devoted to the development of fluorescent probes to detect NTR activities using fluorogenic methods to probe its behaviour in a cellular context; however, NTR-responsive MRI contrast agents are still by far underexplored. In this study, para-nitrobenzyl substituted T1-weighted magnetic resonance imaging (MRI contrast agent Gd-DOTA-PNB (probe 1 has been designed and explored for the possible detection of NTR. Our experimental results show that probe 1 could serve as an MRI-enhanced contrast agent for monitoring NTR activity. The in vitro response and mechanism of the NTR catalysed reduction of probe 1 have been investigated through LC–MS and MRI. Para-nitrobenzyl substituted probe 1 was catalytically reduced by NTR to the intermediate para-aminobenzyl substituted probe which then underwent a rearrangement elimination reaction to Gd-DOTA, generating the enhanced T1-weighted MR imaging. Further, LC–MS and MRI studies of living Escherichia coli have confirmed the NTR activity detection ability of probe 1 at a cellular level. This method may potentially be used for the diagnosis of bacterial infections. KEY WORDS: Nitroreductase, MRI contrast agent, Smart imaging probes, Bacterial imaging, Bacterial infection

  19. X-ray Scatter Imaging of Hepatocellular Carcinoma in a Mouse Model Using Nanoparticle Contrast Agents

    Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; Wands, Jack R.; Rose-Petruck, Christoph

    2015-10-01

    Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. The enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.

  20. Experimental design and instability analysis of coaxial electrospray process for microencapsulation of drugs and imaging agents.

    Si, Ting; Zhang, Leilei; Li, Guangbin; Roberts, Cynthia J; Yin, Xiezhen; Xu, Ronald

    2013-07-01

    Recent developments in multimodal imaging and image-guided therapy requires multilayered microparticles that encapsulate several imaging and therapeutic agents in the same carrier. However, commonly used microencapsulation processes have multiple limitations such as low encapsulation efficiency and loss of bioactivity for the encapsulated biological cargos. To overcome these limitations, we have carried out both experimental and theoretical studies on coaxial electrospray of multilayered microparticles. On the experimental side, an improved coaxial electrospray setup has been developed. A customized coaxial needle assembly combined with two ring electrodes has been used to enhance the stability of the cone and widen the process parameter range of the stable cone-jet mode. With this assembly, we have obtained poly(lactide-co-glycolide) microparticles with fine morphology and uniform size distribution. On the theoretical side, an instability analysis of the coaxial electrified jet has been performed based on the experimental parameters. The effects of process parameters on the formation of different unstable modes have been studied. The reported experimental and theoretical research represents a significant step toward quantitative control and optimization of the coaxial electrospray process for microencapsulation of multiple drugs and imaging agents in multimodal imaging and image-guided therapy.

  1. Effect of ketamine, pentobarbital, and morphine on Tc-99m-DISIDA hepatobiliary kinetics

    Durakovic, A.; Dubois, A.

    1985-01-01

    The purpose of this study was to evaluate hapatobiliary kinetics of Tc-99m-DISIDA in dogs after administration of anesthetic sedative or narcotic agents. Four groups of six male Beagle dogs were studied as a non-treated control group and after parenteral administration of ketamine (30 mg/kg IM), pentobarbital (25 mg/kg IV) or morphine (1 mg/kg IV). Each animal was injected with 4 mCi Tc-99m-DISIDA and hepatobiliary scintigraphic studies were obtained using a gamma camera with parallel hole multipurpose collimator and an A/sup 3/ MDS computer. The authors determined; peak activity of Tc-99m-DISIDA in the liver, visualization and peak activity of gallbladder, and intestinal visualization of Tc-99m-DISIDA. Total bilirubin, LDH, SGOT and SGPT were not modified significantly after any drug compared to control. The results showed that two commonly used anesthetics and sedatives (ketamine and pentobarbital) have dramatic and opposite effects on extrahepatic biliary kinetics. Furthermore, ketamine, but not pentobarbital, significantly accelerates intrahepatic biliary kinetics. Finally, as expected, morphine delayed extrahepatic biliary kinetics. Thus, studies of biliary kinetics should be interpreted with caution when measurements are made after administration of anesthetic, sedative or narcotic agents

  2. Comparative cardiac effects of three hepatobiliary radiopharmacologicals in the dog: concise communication

    Shani, J.; Sarel, O.; Rogel, S.; Weininger, J.; Lubin, E.

    1982-01-01

    Three hepatobiliary agents with an acetanilide-imidoacetic-acid moiety resembling that in lidocaine were investigated for their possible effects on contractility and conductivity in the heart and on arterial pressure and aortic blood flow. This was done in the light of lidocaine's numerous cardiac side effects. HIDA, BIDA, and DIPA, each with traces of decayed /sup 99m/Tc, were injected i.v. into anesthetized dogs with an A-V block, and their effects on the above parameters were followed until control levels were reestablished. Whereas lidocaine raises the diastolic threshold and prolongs the refractory period, the three agents tested do not prolong myocardial conductivity. Both HIDA and BIDA have an effect similar to that of lidocaine, but DIPA has no effect on the latter two parameters. Moreover, whereas lidocaine depressed myocardial contractility, blood pressure, and blood flow, HIDA has a less prominent effect on these parameters, and neither BIDA nor DIPA has any such effect. It is concluded that even though the effect of HIDA on the heart is milder than that of lidocaine, the effects of both BIDA and DIPA are even less pronounced, and they are less likely to cause cardiac side effects when similar doses are administered during nuclear medicine procedures

  3. Comparative cardiac effects of three hepatobiliary radiopharmacologicals in the dog: concise communication

    Shani, J.; Rogel, S.; Weininger, J.; Lubin, E.

    1982-01-01

    Three hepatobiliary agents with an acetanilide-imidoacetic-acid moiety resembling that in lidocaine were investigated for their possible effects on contractility and conductivity in the heart and on arterial pressure and aortic blood flow. This was done in the light of lidocaine's numerous cardiac side effects. HIDA, BIDA, and DIPA, each with traces of decayed Tc-99m, were injected i.v. into anesthetized dogs with an A-V block, and their effects on the above parameters were followed until control levels were reestablished. Wheras lidocaine raises the diastolic threshold and prolongs the refractory period, the three agents tested do not prolong myocardial conductivity. Both HIDA and BIDA have an effect similar to that of lidocaine, but DIPA has no effect on the latter two parameters. Moreover, whereas lidocaine depresses myocardial contractility, blood pressure, and blood flow, HIDA has a less prominent effect on these parameters, and neither BIDA nor DIPA has any such effect. It is concluded that even though the effect of HIDA on the heart is milder than that of lidocaine, the effects of both BIDA and DIPA are even less pronounced, and they are less likely to cause cardiac side effects when similar doses are administered during nuclear medicine procedures

  4. Evaluation of potential practical oral contrast agents for pediatric magnetic resonance imaging

    Bisset, G.S. III; Cincinnati Univ., OH; Children's Hospital Medical Center, Cincinnati, OH

    1989-01-01

    Development of a practical oral contrast agent for magnetic resonance imaging is necessary to improve differentiation of bowel from adjacent structures. In order to find a readily available, inexpensive, non-toxic, palatable solution for use in the pediatric population, several formulas, milk products and a common oral sedative were evaluated in vitro. T1, T2 and signal intensity measurements were performed on a 1.5 T system. Similac with standard iron proved to be a useful high signal intensity agent on multiple pulse sequences. Early in vivo experience in four normal volunteers indicates that this agent provides excellent delineation of the stomach and duodenum from contiguous viscera. Distal small bowel visualization is less predictabel. Further clinical trials should confirm the utility of this solution, which contains a combination of iron salts and paramagnetic metallic ions. (orig.)

  5. Current status of superparamagnetic iron oxide contrast agents for liver magnetic resonance imaging.

    Wang, Yi-Xiang J

    2015-12-21

    Five types of superparamagnetic iron oxide (SPIO), i.e. Ferumoxides (Feridex(®) IV, Berlex Laboratories), Ferucarbotran (Resovist(®), Bayer Healthcare), Ferumoxtran-10 (AMI-227 or Code-7227, Combidex(®), AMAG Pharma; Sinerem(®), Guerbet), NC100150 (Clariscan(®), Nycomed,) and (VSOP C184, Ferropharm) have been designed and clinically tested as magnetic resonance contrast agents. However, until now Resovist(®) is current available in only a few countries. The other four agents have been stopped for further development or withdrawn from the market. Another SPIO agent Ferumoxytol (Feraheme(®)) is approved for the treatment of iron deficiency in adult chronic kidney disease patients. Ferumoxytol is comprised of iron oxide particles surrounded by a carbohydrate coat, and it is being explored as a potential imaging approach for evaluating lymph nodes and certain liver tumors.

  6. Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents

    Estelrich J

    2015-03-01

    Full Text Available Joan Estelrich,1,2 María Jesús Sánchez-Martín,1 Maria Antònia Busquets1,2 1Departament de Fisicoquímica, Facultat de Farmàcia, Universitat de Barcelona, Barcelona, Catalonia, Spain; 2Institut de Nanociència I Nanotecnologia (IN2UB, Barcelona, Catalonia, SpainAbstract: Magnetic resonance imaging (MRI has become one of the most widely used and powerful tools for noninvasive clinical diagnosis owing to its high degree of soft tissue contrast, spatial resolution, and depth of penetration. MRI signal intensity is related to the relaxation times (T1, spin–lattice relaxation and T2, spin–spin relaxation of in vivo water protons. To increase contrast, various inorganic nanoparticles and complexes (the so-called contrast agents are administered prior to the scanning. Shortening T1 and T2 increases the corresponding relaxation rates, 1/T1 and 1/T2, producing hyperintense and hypointense signals respectively in shorter times. Moreover, the signal-to-noise ratio can be improved with the acquisition of a large number of measurements. The contrast agents used are generally based on either iron oxide nanoparticles or ferrites, providing negative contrast in T2-weighted images; or complexes of lanthanide metals (mostly containing gadolinium ions, providing positive contrast in T1-weighted images. Recently, lanthanide complexes have been immobilized in nanostructured materials in order to develop a new class of contrast agents with functions including blood-pool and organ (or tumor targeting. Meanwhile, to overcome the limitations of individual imaging modalities, multimodal imaging techniques have been developed. An important challenge is to design all-in-one contrast agents that can be detected by multimodal techniques. Magnetoliposomes are efficient multimodal contrast agents. They can simultaneously bear both kinds of contrast and can, furthermore, incorporate targeting ligands and chains of polyethylene glycol to enhance the accumulation of

  7. Cell tracking with gadophrin-2: a bifunctional contrast agent for MR imaging, optical imaging, and fluorescence microscopy

    Daldrup-Link, Heike E.; Rudelius, Martina; Piontek, Guido; Schlegel, Juergen; Metz, Stephan; Settles, Marcus; Rummeny, Ernst J.; Pichler, Bernd; Heinzmann, Ulrich; Oostendorp, Robert A.J.

    2004-01-01

    The purpose of this study was to assess the feasibility of use of gadophrin-2 to trace intravenously injected human hematopoietic cells in athymic mice, employing magnetic resonance (MR) imaging, optical imaging (OI), and fluorescence microscopy. Mononuclear peripheral blood cells from GCSF-primed patients were labeled with gadophrin-2 (Schering AG, Berlin, Germany), a paramagnetic and fluorescent metalloporphyrin, using established transfection techniques with cationic liposomes. The labeled cells were evaluated in vitro with electron microscopy and inductively coupled plasma atomic emission spectrometry. Then, 1 x 10 6 -3 x 10 8 labeled cells were injected into 14 nude Balb/c mice and the in vivo cell distribution was evaluated with MR imaging and OI before and 4, 24, and 48 h after intravenous injection (p.i.). Five additional mice served as controls: three mice were untreated controls and two mice were investigated after injection of unlabeled cells. The contrast agent effect was determined quantitatively for MR imaging by calculating signal-to-noise-ratio (SNR) data. After completion of in vivo imaging studies, fluorescence microscopy of excised organs was performed. Intracellular cytoplasmatic uptake of gadophrin-2 was confirmed by electron microscopy. Spectrometry determined an uptake of 31.56 nmol Gd per 10 6 cells. After intravenous injection, the distribution of gadophrin-2 labeled cells in nude mice could be visualized by MR, OI, and fluorescence microscopy. At 4 h p.i., the transplanted cells mainly distributed to lung, liver, and spleen, and 24 h p.i. they also distributed to the bone marrow. Fluorescence microscopy confirmed the distribution of gadophrin-2 labeled cells to these target organs. Gadophrin-2 is suited as a bifunctional contrast agent for MR imaging, OI, and fluorescence microscopy and may be used to combine the advantages of each individual imaging modality for in vivo tracking of intravenously injected hematopoietic cells. (orig.)

  8. Automated synthesis of the estrogen receptors imaging agent 18F-FES

    Guo Shen; Chen Guobao; Dai Hongfeng; Lin Meifu; Chen Wenxin

    2011-01-01

    Objective: 18 F-16α-17β-fluoroestradiol ( 18 F-FES), an estrogen receptors imaging agent, is synthesized with Tracerlab FX FN system. Methods: 18 F-FES is obtained by two steps reactions, including the nucleophilic displacement reaction of no-carrier-added 18 F-fluoride with 3-O-methoxymethyl-16, 17-O-sulfuryl-16-epiesteriol, then the intermediate is evaporated and hydrolyzed with HCI and finally gives 18 F-FES. Results: The synthesis of 18 F-FES can be completed in about 80 min.The radiochemical yield and radio-chemical purity are about 10% and 95% respectively. Conclusion: The procedure of synthesis is simple and automatical. 18 F-FES has an extremely low toxicity, which suggests that 18 F-FES may be a safe, a nd effective estrogen receptors imaging agent. (authors)

  9. Semiconducting polymer dot as a highly effective contrast agent for photoacoustic imaging

    Yuan, Zhen; Zhang, Jian

    2018-02-01

    In this study, we developed a novel PIID-DTBT based semiconducting polymer dots (Pdots) that have broad and strong optical absorption in the visible-light region (500 nm - 700 nm). Gold nanoparticles (GNPs) and gold nanorods (GNRs) that have been verified as an excellent photoacoustic contrast agent were compared with Pdots based on photoacoustic imaging method. Both ex vivo and in vivo experiment demonstrated Pdots have a better photoacoustic conversion efficiency at 532 nm than GNPs and similar photoacoustic performance with GNRs at 700 nm at the same mass concentration. Our work demonstrates the great potential of Pdots as a highly effective contrast agent for precise localization of lesions relative to the blood vessels based on photoacoustic tomography imaging.

  10. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang [The First Affiliated Hospital of Zhengzhou University, Department of Radiology, Zhengzhou, Henan Province (China)

    2017-01-15

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  11. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  12. Highly stabilized gadolinium chelates functionalized on metal nanoparticles as magnetic resonance imaging contrast agent

    Siddiqui, Talha S.

    Magnetic resonance imaging (MRI) is a non-invasive method for imaging and diagnosing tissue damage, organ function and the vascular system. Magnevist(TM) a complex of diethylenetriaminepentaacetic acid (DTPA) and Gd3+ is a clinically approved contrast agent for MRI. A derivative of DTPA was formed by the addition of two cysteine groups (DTPA-L-Cys) through amide linkage. The Gd complex of this ligand bonds with the silver surfaces through the cysteine thiols. GdDTPA-L-Cys was bound to ˜10nm diameter Ag nanoparticles for use as a multifunctional MRI contrast agent. The ligand and complex were characterized by 1H and 13C NMR, ESI-MS and IR spectroscopy. The silver construct was characterized by TEM, TGA and UV-Vis absorption spectra. The per metal complex r1 relaxivity of GdDTPA-L-Cys{Ag} greater than that of Magnavist(TM) with the same molarity for both compounds. The synthesis of a DTPA derivative is described that allows it to bind to silver or gold nanoparticles through a single thiol linkage (DTPASH). The resulting Gd complex, GdDTPASH, was bound to Ag nanoparticles to create a single monolayer on the surface. The construct was further stabilized in buffered solution with the addition of a thiolated PEG chain. The highly stabilized nanoparticle construct delivers a high payload of Gd compelex and is an effective T1 brightening agent. The production of this type of construct opens the way for engineered multimodal MRI contrast agents.

  13. Optical-based molecular imaging: contrast agents and potential medical applications

    Bremer, Christoph; Ntziachristos, Vasilis; Weissleder, Ralph

    2003-01-01

    Laser- and sensitive charge-coupled device technology together with advanced mathematical modelling of photon propagation in tissue has prompted the development of novel optical imaging technologies. Fast surface-weighted imaging modalities, such as fluorescence reflectance imaging (FRI) and 3D quantitative fluorescence-mediated tomography have now become available [1, 2]. These technical advances are paralleled by a rapid development of a whole range of new optical contrasting strategies, which are designed to generate molecular contrast within a living organism. The combination of both, technical advances of light detection and the refinement of optical contrast media, finally yields a new spectrum of tools for in vivo molecular diagnostics. Whereas the technical aspects of optical imaging are covered in more detail in a previous review article in ''European Radiology'' [3], this article focuses on new developments in optical contrasting strategies and design of optical contrast agents for in vivo diagnostics. (orig.)

  14. Gaucher disease in the liver on hepatocyte specific contrast agent enhanced MR imaging

    Ayyala, Rama S.; Teot, Lisa A.; Perez Rossello, Jeanette M.

    2017-01-01

    Gaucher disease is a hereditary lipid storage disorder that affects the enzyme beta glucocerebrosidase, causing accumulation of glucocerebroside in macrophages of the reticuloendothelial system. Accumulation can occur in the liver and spleen, manifesting as hepatosplenomegaly, as well as within the bone marrow. Hepatic involvement is usually diffuse but can occasionally manifest as focal liver lesions. We present a case of a 2-year-old boy with Gaucher disease and an infiltrating liver lesion detected on imaging, which was pathologically shown to be focal changes related to the disease. Imaging characteristics of this lesion using hepatocyte specific contrast agent enhanced MRI, which have not been previously discussed in the literature, are described. (orig.)

  15. Evaluation of 18F-labeled icotinib derivatives as potential PET agents for tumor imaging

    Hongyu Ren; Hongyu Ning; Jin Chang; Mingxia Zhao; Yong He; Yan Chong; Chuanmin Qi

    2016-01-01

    In this study, three 18 F-labeled crown ether fused anilinoquinazoline derivatives ([ 18 F]11a-c) were synthesized and evaluated as potential tumor imaging probes. The biodistribution results of [ 18 F]11b were good. Compared with [ 18 F]-fludeoxyglucose and l-[ 18 F]-fluoroethyltyrosine in the same animal model, [ 18 F]11b had better tumor/brain, tumor/muscle, and tumor/blood uptake ratios. Overall, these results suggest that [ 18 F]11b is promising as a tumor imaging agent for positron emission tomography. (author)

  16. Evaluation of /sup 201/TlCl and delayed scan for thyroid imaging agent

    Taniguchi, Tatsuyoshi; Harada, Taneichi; Takahashi, Tatsuo; Senoo, Tsuneaki; Ohtsuka, Nobuaki; Ito, Yasuhiko [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1982-11-01

    The results of 189 patients with nodular goiter by imaging with /sup 201/TlCl following with sup(99m)TcO/sub 4//sup -/ was presented. Accumulation of /sup 201/TlCl to the corresponding area was observed in 85.5% of cancer, 62.2% of adenoma, 42.5% of adenomatous goiter, and the usefulness of /sup 201/TlCl (early scan) for thyroid imaging agent was recognized. On the other hand, delayed scan for purpose of differentiation from benign to malignant was also performed. However, no significant differences were obtained.

  17. Gaucher disease in the liver on hepatocyte specific contrast agent enhanced MR imaging

    Ayyala, Rama S. [Morgan Stanley Children' s Hospital, Department of Radiology, Columbia University Medical Center, New York, NY (United States); Teot, Lisa A. [Boston Children' s Hospital, Department of Pathology, Harvard Medical School, Boston, MA (United States); Perez Rossello, Jeanette M. [Boston Children' s Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States)

    2017-04-15

    Gaucher disease is a hereditary lipid storage disorder that affects the enzyme beta glucocerebrosidase, causing accumulation of glucocerebroside in macrophages of the reticuloendothelial system. Accumulation can occur in the liver and spleen, manifesting as hepatosplenomegaly, as well as within the bone marrow. Hepatic involvement is usually diffuse but can occasionally manifest as focal liver lesions. We present a case of a 2-year-old boy with Gaucher disease and an infiltrating liver lesion detected on imaging, which was pathologically shown to be focal changes related to the disease. Imaging characteristics of this lesion using hepatocyte specific contrast agent enhanced MRI, which have not been previously discussed in the literature, are described. (orig.)

  18. Radiolabeled adrenergic neuron-blocking agents: Adrenomedullary imaging with [131I]iodobenzylguanidine

    Wieland, D.M.; Wu, J.; Brown, L.E.; Mangner, T.J.; Swanson, D.P.; Beierwaltes, W.H.

    1980-01-01

    The tissue distributions of three radioiodinated neuron-blocking agents have been determined in dogs. Iodine-125-labeled meta- and para-iodobenzylguanidines show a striking affinity for, and retention in, the adrenal medulla. Peak concentrations of the two isomers exceed those of previously reported adrenophilic compounds. High myocardial concentrations were also observed at early time intervals. Images of the dog's adrenal medullae have been obtained with para[ 131 I]-iodobenzylguanidine

  19. Pharmacological studies of dopamine transporter imaging agent 125/131I-β-CIT

    Ding Shiyu; Zhou Xiang; Chen Zhengping; Wu Chunying; Lin Yansong; Ji Shuren; Lu Chunxiong; Fang Ping; Tang Jun; Wang Feng

    2001-01-01

    To prepare 125/131 I-β-CIT (2β-carbomethoxy-3β-(4-iodophenyl) tropane) as an imaging agent for dopamine transporter (DAT), the labelling method from tributylstannyl precursor with peracetic acid has been reported. The radiochemical purity (RCP) of the labelled compound was over 95% determined by HPLC and TLC. The stability, partition coefficients were also determined. The pharmacological studies of the imaging agent were performed in rats, mice, rabbits and normal monkey. The ligand showed preferable uptake in brain (1.9% ID/organ in rats and 4.5% ID/organ in mice at 5 min). The ratios of striatum/cerebellum, hippocampus/cerebellum and cortex/cerebellum were 28.9, 3.97 and 4.75 at 6 h in rats, and 8.52, 2.99 and 3.06 at 6 h in mice, respectively. In monkey brain imaging the ratios of striatum/frontal cortex (ST/FC) and striatum/occipital cortex (ST/OC) were 5.14 and 5.97 at 4h, respectively. All of above showed the high affinity of the ligand to DAT. The compound was primarily metabolized in liver because the hepatic uptake was much higher than other organs (75.4% ID/organ at 18h). The half-life of blood elimination was 5 min. The dose received by mice was 2500 times as high as that received by human in the test of undue toxicity, which evaluated the safety of the agent. All the results suggest that β-CIT can be used as a potential DAT imaging agent

  20. Transforming a Targeted Porphyrin Theranostic Agent into a PET Imaging Probe for Cancer

    Jiyun Shi, Tracy W.B. Liu, Juan Chen, David Green, David Jaffray, Brian C. Wilson, Fan Wang, Gang Zheng

    2011-01-01

    Full Text Available Porphyrin based photosensitizers are useful agents for photodynamic therapy (PDT and fluorescence imaging of cancer. Porphyrins are also excellent metal chelators forming highly stable metallo-complexes making them efficient delivery vehicles for radioisotopes. Here we investigated the possibility of incorporating 64Cu into a porphyrin-peptide-folate (PPF probe developed previously as folate receptor (FR targeted fluorescent/PDT agent, and evaluated the potential of turning the resulting 64Cu-PPF into a positron emission tomography (PET probe for cancer imaging. Noninvasive PET imaging followed by radioassay evaluated the tumor accumulation, pharmacokinetics and biodistribution of 64Cu-PPF. 64Cu-PPF uptake in FR-positive tumors was visible on small-animal PET images with high tumor-to-muscle ratio (8.88 ± 3.60 observed after 24 h. Competitive blocking studies confirmed the FR-mediated tracer uptake by the tumor. The ease of efficient 64Cu-radiolabeling of PPF while retaining its favorable biodistribution, pharmacokinetics and selective tumor uptake, provides a robust strategy to transform tumor-targeted porphyrin-based photosensitizers into PET imaging probes.

  1. Evaluation of chirp reversal power modulation sequence for contrast agent imaging

    Novell, A; Sennoga, CA; Escoffre, JM; Chaline, J; Bouakaz, A

    2014-01-01

    Over the last decade, significant research effort has been focused on the use of chirp for contrast agent imaging because chirps are known to significantly increase imaging contrast-to-noise ratio (CNR). New imaging schemes, such as chirp reversal (CR), have been developed to improve contrast detection by increasing non-linear microbubble responses. In this study we evaluated the contrast enhancement efficiency of various chirped imaging sequences in combination with well-established imaging schemes such as power modulation (PM) and pulse inversion (PI). The imaging schemes tested were implemented on a fully programmable open scanner and evaluated by ultrasonically scanning (excitation frequency of 2.5 MHz; amplitude of 350 kPa) a tissue-mimicking flow phantom comprising a 4 mm diameter tube through which aqueous dispersions (dilution fraction of 1/2000) of the commercial ultrasound contrast agent, SonoVue ® were continuously circulated. The recovery of non-linear microbubble responses after chirp compression requires the development and the optimization of a specific filter. A compression filter was therefore designed and used to compress and extract several non-linear components from the received microbubble responses. The results showed that using chirps increased the image CNR by approximately 10 dB, as compared to conventional Gaussian apodized sine burst excitation but degraded the axial resolution by a factor of 1.4, at −3 dB. We demonstrated that the highest CNR and contrast-to-noise ratio (CTR) were achievable when CR was combined with PM as compared to other imaging schemes such as PI. (paper)

  2. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  3. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    Xing Zhanwen; Ke Hengte; Yue Xiuli; Dai Zhifei [Nanobiotechnology Division, State Key Laboratory of Urban Water Resources and Environment, School of Sciences, Harbin Institute of Technology, Harbin 150080 (China); Wang Jinrui; Zhao Bo [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Liu Jibin, E-mail: zhifei.dai@hit.edu.cn, E-mail: ji-bin.liu@jefferson.edu [Ultrasound Research and Education Institute, Thomas Jefferson University, Philadelphia, PA 19107 (United States)

    2010-04-09

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  4. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    Xing Zhanwen; Ke Hengte; Yue Xiuli; Dai Zhifei; Wang Jinrui; Zhao Bo; Liu Jibin

    2010-01-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  5. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    Xing, Zhanwen; Wang, Jinrui; Ke, Hengte; Zhao, Bo; Yue, Xiuli; Dai, Zhifei; Liu, Jibin

    2010-04-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  6. Experimental study of 99Tcm-tri-peptide as a novel tumor imaging agent

    Xie Wenhui; Cai Xiaojia; Liu Ciyi; Zeng Jun; Zhang Lihua; Lei Bei; Huang Gang

    2011-01-01

    Objective: To evaluate 99 Tc m -Arg-Glu-Ser ( 99 Tc m -RES) as a potential tumor imaging agent. Methods: RES was synthesized using solid phase peptide synthesis. The optimal labeling conditions of RES were determined under different reagents and reacting temperatures using SnC1 2 as reducing agent.The biodistribution of 99 Tc m -RES was studied in nude mice bearing human lung cancer A549. Results: The radiochemical purity of 99 Tc m -RES was up to 85% and the radiochemical purity was 75% ever after 6 h at room temperature. The tumor uptake of 99 Tc m -RES was obvious and the radioactivity ratios of tumor/blood, tumor/heart, tumor/liver, tumor/lung, tumor/spleen and tumor/muscle were 5.31, 1.88, 1.57, 3.58, 4.16 and 5.92, respectively at 6 h after 99 Tc m -RES injection. Gamma camera imaging showed that tumor uptake of 99 Tc m -RES was negative in rabbits with inflammatory mass but positive in those bearing tumor. The radioactivity ratio of tumor/inflammation was 3.12 at 6 h after injection. Conclusion: 99 Tc m -RES might possibly become a potential tumor imaging agent. (authors)

  7. MRI contrast agent for molecular imaging of the HER2/neu receptor using targeted magnetic nanoparticles

    Rasaneh, Samira; Rajabi, Hossein, E-mail: hrajabi@modares.ac.ir [Tarbiat Modares University, Department of Medical Physics (Iran, Islamic Republic of); Babaei, Mohammad Hossein [Nuclear Science and Technology Research Institute, Department of Radioisotope (Iran, Islamic Republic of); Akhlaghpoor, Shahram [Sina Hospital, Tehran Medical University, Noor Medical Imaging Center (Iran, Islamic Republic of)

    2011-06-15

    In this study, Trastuzumab modified Magnetic Nanoparticles (TMNs) were prepared as a new contrast agent for detecting HER2 (Human epidermal growth factor receptor-2) expression tumors by magnetic resonance imaging (MRI). TMNs were prepared based on iron oxide nanoparticles core and Trastuzumab modified dextran coating. The TMNs core and hydrodynamic size were determined by transmission electron microscopy and dynamic light scattering. TMNs stability and cytotoxicity were investigated. The ability of TMNs for HER2 detection were evaluated in breast carcinoma cell lines (SKBr3 and MCF7 cells) and tumor-bearing mice by MRI and iron uptake determination. The particles core and hydrodynamic size were 9 {+-} 2.5 and 41 {+-} 15 nm (size range: 15-87 nm), respectively. The molar antibody/nanoparticle ratio was 3.1-3.5. TMNs were non-toxic to the cells below the 30 {mu}g (Fe)/mL concentration and good stable up to 8 weeks in PBS buffer. TMNs could detect HER2 oncogenes in the cells surface with imagable contrast by MRI. The invivo study in mice bearing tumors indicated that TMNs possessed a good diagnostic ability as HER2 specific contrast agent by MRI. TMNs were demonstrated to be able to selectively accumulate in the tumor cells, with a proper signal enhancement in MRI T2 images. So, the complex may be considered for further investigations as an MRI contrast agent for detection of HER2 expression tumors in human.

  8. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.

  9. The changes of bile dynamics in patients with gallstones by quantitative hepatobiliary scintigraphy

    Xu Wei'na; Yu Shupeng

    2004-01-01

    The gold standard of diagnosing SOD is endoscopic sphincter of Oddi manometry, but it is not widely used because it is invasive, expensive and there are more complicateds after examination. Hepatobiliary scintigraphy can give us quantitative parameters of bile emptying and it is a noninvasive, sensitive and accurate method in diagnosing SOD. The bile dynamics after cholecystectomy was seldom studied, the aim of this study is to obtain the normal changes of bile emptying after cholecystectomy by hepatobiliary scintigraphy and provide basis for diagnosing SOD. Objective: Quantitative hepatobiliary scintigraphy, a noninvasive method used to diagnose dysfunction of bile duct, can show bile secretion and outflow in bile duct. The goal of this study was to examine the dynamics of bile secretion and outflow by quantitative hepatobiliary scintigraphy in patients with gallstones, postcholecystectomy and normal groups, got the parameters of normal changes of bile emptying in postcholecystectomy patients and to help diagnosing SOD. Methods: 1 Patients. 31 patients with gallstones, demonstrated single or multiple gallstones by abdominal ultrasonography; 12 normal controls and 12 patients after cholecystectomy. They were all rulled out liver diseases and bile duct stones by liver function tests and US respectively, the diameter of common bile duct were normal, liver functions were normal and there were not symptoms of bile duct diseases. 2 Methods. All the patients were examined by fatty meal * hepatobiliary scintigraphy according to the same method. after fasting over 4 hours, 740 MBq 99m Tc-EHIDA was injected intravenously. Images were recorded continuously at one frame per minute for 100 minutes, at 60th minute two fry eggs were taken. Then the parameters of of bile emptying (Tmax in liver and common bile duct, T1/2 in liver and common bile duct, time of duodenal appeared (DAT), transit time from liver to duodenol(HDTT) and half-emptying time in common bile duct after fatty

  10. Biodegradable polymer based theranostic agents for photoacoustic imaging and cancer therapy

    Wang, Yan J.; Strohm, Eric M.; Kolios, Michael C.

    2016-03-01

    In this study, multifunctional theranostic agents for photoacoustic (PA), ultrasound (US), fluorescent imaging, and for therapeutic drug delivery were developed and tested. These agents consisted of a shell made from a biodegradable Poly(lactide-co-glycolic acid) (PLGA) polymer, loaded with perfluorohexane (PFH) liquid and gold nanoparticles (GNPs) in the core, and lipophilic carbocyanines fluorescent dye DiD and therapeutic drug Paclitaxel (PAC) in the shell. Their multifunctional capacity was investigated in an in vitro study. The PLGA/PFH/DiD-GNPs particles were synthesized by a double emulsion technique. The average PLGA particle diameter was 560 nm, with 50 nm diameter silica-coated gold nano-spheres in the shell. MCF7 human breast cancer cells were incubated with PLGA/PFH/DiDGNPs for 24 hours. Fluorescent and PA images were recorded using a fluorescent/PA microscope using a 1000 MHz transducer and a 532 nm pulsed laser. For the particle vaporization and drug delivery test, MCF7 cells were incubated with the PLGA/PFH-GNPs-PAC or PLGA/PFH-GNPs particles for 6, 12 and 24 hours. The effects of particle vaporization and drug delivery inside the cells were examined by irradiating the cells with a laser fluence of 100 mJ/cm2, and cell viability quantified using the MTT assay. The PA images of MCF7 cells containing PLGA/PFH/DiD-GNPs were spatially coincident with the fluorescent images, and confirmed particle uptake. After exposure to the PLGA/PFHGNP- PAC for 6, 12 and 24 hours, the cell survival rate was 43%, 38%, and 36% respectively compared with the control group, confirming drug delivery and release inside the cells. Upon vaporization, cell viability decreased to 20%. The particles show potential as imaging agents and drug delivery vehicles.

  11. Colorectal liver metastases: contrast agent diffusion coefficient for quantification of contrast enhancement heterogeneity at MR imaging.

    Jia, Guang; O'Dell, Craig; Heverhagen, Johannes T; Yang, Xiangyu; Liang, Jiachao; Jacko, Richard V; Sammet, Steffen; Pellas, Theodore; Cole, Patricia; Knopp, Michael V

    2008-09-01

    To describe and determine the reproducibility of a simplified model to quantitatively measure heterogeneous intralesion contrast agent diffusion in colorectal liver metastases. This HIPAA-compliant retrospective study received institutional review board approval, and written informed consent was obtained from 14 patients (mean age, 61 years +/- 9 [standard deviation]; range, 41-78 years), including 10 men (mean age, 65 years +/- 8; range, 47-78 years) and four women (mean age, 54 years +/- 9; range, 41-59 years), with colorectal liver metastases. Magnetic resonance (MR) imaging was performed twice (first baseline MR image [B(1)] and second baseline MR image [B(2)]) in a single target lesion prior to therapy. Dynamic contrast material-enhanced MR imaging was performed by using a saturation-recovery fast gradient-echo sequence. A simplified contrast agent diffusion model was proposed, and a contrast agent diffusion coefficient (CDC) was calculated. The reproducibility of the CDC measurement was evaluated by using the Bland-Altman plot and a linear regression model. The mean CDC was 0.22 mm(2)/sec (range, 0.01-0.73 mm(2)/sec) on B(1) and 0.24 mm(2)/sec (range, 0.01-0.71 mm(2)/sec) on B(2), with an intraclass correlation coefficient of 0.91 (P < .0001). Bland-Altman plot showed good agreement, with a mean difference in measurement pairs of 0.017 mm(2)/sec +/- 0.096. The slope from the linear regression model was 0.89 (95% confidence interval: 0.63, 1.15) and the intercept was 0.01 (95% confidence interval: -0.08, 0.09). The CDC enables a quantitative description of contrast enhancement heterogeneity in lesions. Given the high reproducibility of the CDC metric, CDC appears promising for further qualification as an imaging biomarker of change measurement in response assessment. http://radiology.rsnajnls.org/cgi/content/full/248/3/901/DC1. RSNA, 2008

  12. 99m Tc-tazobactam, a novel infection imaging agent: Radiosynthesis, quality control, biodistribution, and infection imaging studies.

    Rasheed, Rashid; Naqvi, Syed Ali Raza; Gillani, Syed Jawad Hussain; Zahoor, Ameer Fawad; Jielani, Asif; Saeed, Nidda

    2017-05-15

    The radiolabeled drug 99m Tc-tazobactam ( 99m Tc-TZB) was developed and assessed as an infection imaging agent in Pseudomonas aeruginosa and Salmonella enterica infection-induced animal models by comparing with inflammation induced animal models. Radiosynthesis of 99m Tc-TZB was assessed while changing ligand concentration, reducing agent concentration, pH, and reaction time while keeping radioactivity constant (~370 MBq). Percent labeling of the resulting complex was measured using paper chromatography and instant thin layer chromatography. The analysis of the 99m Tc-TZB complex indicated >95% labeling yield and electrophoresis revealed complex is neutral in nature. The biodistribution study also showed predominantly renal excretion; however liver, stomach, and intestine also showed slight tracer agent uptake. The agent significantly accumulated in Pseudomonas aeruginosa and Salmonella enterica infection induced tissues 3.58 ± 0.26% and 2.43 ± 0.42% respectively at 1 hour postinjection. The inflamed tissue failed to uptake noticeable activity at 1 hour time point. The scintigraphic study results were found in accordance with biodistribution pattern. On the basis of our preliminary results, the newly developed 99m Tc-TZB can be used to diagnose bacterial infection and to discriminate between infected and inflamed tissues. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Development of 99mTc agents for imaging central neural system receptors

    2004-01-01

    Radiopharmaceuticals that bind to central neural system (CNS) receptors in vivo are potentially useful for understanding the pathophysiology of anumber of neurological and psychiatric disorders, their diagnosis and treatment. Carbon-11 labelled compounds and positron emission tomography(PET) imaging have played a vital role in establishing the usefulness of imaging the dopaminergic, cholinergic, serotonergic and benzodiazapine receptors, and relating the receptor density to disease status. Since the use of 11C agents is constrained due to their 20 min half-life, various radiohalogenated analogues based on the structure of 11C compounds have been successfully developed, providing comparable information. Iodine- 123 is the most widely employed of these radioisotopes; it has a longer, 13 h, half-life. Through the use of 123I, there has been a steady growth in CNS receptor imaging studies employing single photon emission computerized tomography (SPECT). SPECT, as compared with PET, has slightly inferior image resolution but has the advantage of being readily available worldwide. However, the 123I radiopharmaceutical is expensive and the distribution system outside of the major markets is not well developed for its supply on a routine basis. The ideal radioisotope for SPECT imaging is 99mTc, due to its low cost per dose, availability through commercially available generator systems and physical decay characteristics. Over 80% of all diagnostic nuclear medicine imaging studies worldwide are conducted using this radioisotope. Development of 99mTc radiopharmaceuticals for imaging CNS receptors is therefore of considerable importance. On the basis of the recommendations of a consultants meeting, the International Atomic Energy Agency (IAEA) initiated in 1996 a Co-ordinated Research Project (CRP) on Development of Agents for Imaging CNS Receptors based on 99mTc. At that time there were no 99mTc CNS receptor imaging radiopharmaceuticals available even though work on

  14. Basic studies on the hepatobiliary scintigraphy with 123I-rose bengal

    Narabayashi, Isamu; Ito, Yasuhiko; Otsuka, Nobuaki; Muranaka, Akira; Konno, Katsunobu.

    1979-01-01

    The purpose of this investigation is to evaluate the values of 123 I-rose bengal. sup(99m)Tc-labels for the hepatobiliary radiopharmaceutical are not fully satisfied because of greater urinary excretion, especially in cases of hyperbilirubinemia. 123 I is a lower gamma ray energy emitter more suitable for imaging and has a short half life with 13 hours. Commercially obtained rose bengal was purified using Sephadex G-25 column on gelfiltration. 123 I-rose bengal was prepared using iodine exchange reaction between nonradioactive rose bengal and Na 123 I. Radiochemical purity of 123 I-rose bengal was examined by paper chromatography. Biological distribution of 123 I-rose bengal in rabbits at 1 hours after intravenous injection indicated that the tracer was cleared from the blood to the liver, thereafter excreted into the small intestine through the common bile duct. Hepatic uptake and excretion of activity has been measured for 60 minutes using a scintillation camera in conjunction with a VTR system. There existed no significant relative to those of 131 I-rose bengal. Serial scintigraphic images showed satisfactorily better images even in a rabbit with complete obstructive jaundice. (author)

  15. In vivo 3D PIXE-micron-CT imaging of Drosophila melanogaster using a contrast agent

    Matsuyama, Shigeo; Hamada, Naoki; Ishii, Keizo; Nozawa, Yuichiro; Ohkura, Satoru; Terakawa, Atsuki; Hatori, Yoshinobu; Fujiki, Kota; Fujiwara, Mitsuhiro; Toyama, Sho

    2015-04-01

    In this study, we developed a three-dimensional (3D) computed tomography (CT) in vivo imaging system for imaging small insects with micrometer resolution. The 3D CT imaging system, referred to as 3D PIXE-micron-CT (PIXEμCT), uses characteristic X-rays produced by ion microbeam bombardment of a metal target. PIXEμCT was used to observe the body organs and internal structure of a living Drosophila melanogaster. Although the organs of the thorax were clearly imaged, the digestive organs in the abdominal cavity could not be clearly discerned initially, with the exception of the rectum and the Malpighian tubule. To enhance the abdominal images, a barium sulfate powder radiocontrast agent was added. For the first time, 3D images of the ventriculus of a living D. melanogaster were obtained. Our results showed that PIXEμCT can provide in vivo 3D-CT images that reflect correctly the structure of individual living organs, which is expected to be very useful in biological research.

  16. The benefits of paired-agent imaging in molecular-guided surgery: an update on methods and applications (Conference Presentation)

    Tichauer, Kenneth M.

    2016-03-01

    One of the major complications with conventional imaging-agent-based molecular imaging, particularly for cancer imaging, is variability in agent delivery and nonspecific retention in biological tissue. Such factors can account to "swamp" the signal arising from specifically bound imaging agent, which is presumably indicative of the concentration of targeted biomolecule. In the 1950s, Pressman et al. proposed a method of accounting for these delivery and retention effects by normalizing targeted antibody retention to the retention of a co-administered "untargeted"/control imaging agent [1]. Our group resurrected the approach within the last 5 years, finding ways to utilize this so-called "paired-agent" imaging approach to directly quantify biomolecule concentration in tissue (in vitro, ex vivo, and in vivo) [2]. These novel paired-agent imaging approaches capable of quantifying biomolecule concentration provide enormous potential for being adapted to and optimizing molecular-guided surgery, which has a principle goal of identifying distinct biological tissues (tumor, nerves, etc…) based on their distinct molecular environment. This presentation will cover the principles and nuances of paired-agent imaging, as well as the current status of the field and future applications. [1] D. Pressman, E. D. Day, and M. Blau, "The use of paired labeling in the determination of tumor-localizing antibodies," Cancer Res, 17(9), 845-50 (1957). [2] K. M. Tichauer, Y. Wang, B. W. Pogue et al., "Quantitative in vivo cell-surface receptor imaging in oncology: kinetic modeling and paired-agent principles from nuclear medicine and optical imaging," Phys Med Biol, 60(14), R239-69 (2015).

  17. Paired-agent fluorescent imaging to detect micrometastases in breast sentinel lymph node biopsy: experiment design and protocol development

    Li, Chengyue; Xu, Xiaochun; Basheer, Yusairah; He, Yusheng; Sattar, Husain A.; Brankov, Jovan G.; Tichauer, Kenneth M.

    2018-02-01

    Sentinel lymph node status is a critical prognostic factor in breast cancer treatment and is essential to guide future adjuvant treatment. The estimation that 20-60% of micrometastases are missed by conventional pathology has created a demand for the development of more accurate approaches. Here, a paired-agent imaging approach is presented that employs a control imaging agent to allow rapid, quantitative mapping of microscopic populations of tumor cells in lymph nodes to guide pathology sectioning. To test the feasibility of this approach to identify micrometastases, healthy pig lymph nodes were stained with targeted and control imaging agent solution to evaluate the potential for the agents to diffuse into and out of intact nodes. Aby-029, an anti-EGFR affibody was labeled with IRDye 800CW (LICOR) as targeted agent and IRDye 700DX was hydrolyzed as a control agent. Lymph nodes were stained and rinsed by directly injecting the agents into the lymph nodes after immobilization in agarose gel. Subsequently, lymph nodes were frozen-sectioned and imaged under an 80-um resolution fluorescence imaging system (Pearl, LICOR) to confirm equivalence of spatial distribution of both agents in the entire node. The binding potentials were acquired by a pixel-by-pixel calculation and was found to be 0.02 +/- 0.06 along the lymph node in the absence of binding. The results demonstrate this approach's potential to enhance the sensitivity of lymph node pathology by detecting fewer than 1000 cell in a whole human lymph node.

  18. Value of hepatobiliary scanning in complex liver trauma

    Gartman, D.M.; Zeman, R.K.; Cahow, C.E.; Baker, C.C.

    1985-01-01

    To evaluate the use of biliary scintigraphy with /sup 99m/Tc-dimethyl analogs (HIDA) in traumatic liver injuries, a group of 26 patients with penetrating and blunt liver injuries were studied. The results indicate that HIDA scanning is an effective noninvasive method of evaluating the hepatobiliary tree in the post-traumatic setting. The HIDA scan is a sensitive tool for studying the hepatic parenchyma and the presence or absence of bile leaks. Its evaluation of the extrahepatic biliary ductal system is not specific and should be assessed with further studies. Gallbladder nonvisualization by HIDA scans in this setting cannot be presumed to be secondary to acute cholecystitis and should be interpreted with extreme caution

  19. Hepatobiliary scanning in cardiac transplant patients maintained on cyclosporine

    Dhekne, R.D.; Long, S.E.; Moore, W.H.; Frazier, O.H.

    1987-01-01

    Many patients receiving cyclosporine (CSA) develop hepatic dysfunction or pancreatitis. The authors reviewed 106 records of cardiac transplant patients maintained on CSA. Eleven patients underwent 16 hepatobiliary scans (HBSs) for abdominal pain and/or abnormal liver function. Of 16 HBSs, ten demonstrated normal gallbladder visualization. Follow-up in all cases confirmed scan findings. Five patients had no gallbladder visualization; confirmation of acute cholecystitis was obtained by surgery in two and by autopsy in three. One patient had previous cholecystectomy. The authors found HPS useful for evaluating acute cholecystitis in patients receiving CSA with or without associated drug-related pancreatitis and hepatic insufficiency and suggest that HBS can assist in the selection of patients for CSA dose adjustment

  20. Mn-DPDP, the first contrast agent for the pancreas

    Gehl, H.B.; Vorwerk, D.; Klose, K.C.; Raber, H.; Guenther, R.W.

    1990-01-01

    Mn-DPDP, known as a contrast agent for the hepatobiliary system, shows signal intensity increase of the pancreas as well. This paper describes the extent of signal intensity increase in the pancreas as a function of time. Six healthy volunteers were imaged with a 1.5-T MR unit using a T1-weighted gradient-echo sequence. Acquisitions were taken in 3-minute intervals for the first 45 minutes, followed by intervals of 30 minutes for 7 hours after infusion of Mn-DPDP. As a special formulation, 10 μmol per kg Mn-DPDP were infused. The enhancement of the head and the tail of the pancreas were measured and plotted as a function of time; the percentage increase in pancreas signal intensity was calculated and compared with the increase in liver signal intensity

  1. Synthesis, biological evaluation, and baboon PET imaging of the potential adrenal imaging agent cholesteryl-p-[18f]fluorobenzoate

    Jonson, Stephanie D.; Welch, Michael J.

    1999-01-01

    Cholesteryl-p-[ 18 F]fluorobenzoate ([ 18 F]CFB) was investigated as a potential adrenal positron emission tomography (PET) imaging agent for the diagnostic imaging of adrenal disorders. We describe the synthesis, biodistribution, adrenal autoradiography, and baboon PET imaging of [ 18 F]CFB. The synthesis of [ 18 F]CFB was facilitated by the use of a specially designed microwave cavity that was instrumental in effecting 70-83% incorporation of fluorine-18 in 60 s via [ 18 F]fluoro-for-nitro exchange. Tissue distribution studies in mature female Sprague-Dawley rats showed good accumulation of [ 18 F]CFB in the steroid-secreting tissues, adrenals and ovaries, at 1 h postinjection. The effectiveness of [ 18 F]CFB to accumulate in diseased adrenals was shown through biodistribution studies in hypolipidemic rats, which showed a greater than threefold increase in adrenal uptake at 1 h and increased adrenal/liver and adrenal/kidney ratios. Analysis of the metabolites at 1 h in the blood, adrenals, spleen, and ovaries of hypolipidemic and control rats showed the intact tracer representing greater than 86%, 93%, 92%, and 82% of the accumulated activity, respectively. [ 18 F]CFB was confirmed to selectively accumulate in the adrenal cortex versus the adrenal medulla by autoradiography. Normal baboon PET imaging with [ 18 F]CFB effectively showed adrenal localization as early as 15 min after injection of the tracer, with enhanced adrenal contrast seen at 60-70 min. These results suggest that [ 18 F]CFB may be useful as an adrenal PET imaging agent for assessing adrenal disorders

  2. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    Li, K.C.P.; Tart, R.P.; Fitzsimmons, J.R.; Storm, B.; Mao, J.

    1989-01-01

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  3. Residualization Rates of Near Infrared Dyes for the Rational Design of Molecular Imaging Agents

    Cilliers, Cornelius; Liao, Jianshan; Atangcho, Lydia; Thurber, Greg M.

    2016-01-01

    Purpose Near infrared (NIR) fluorescence imaging is widely used for tracking antibodies and biomolecules in vivo. Clinical and preclinical applications include intraoperative imaging, tracking therapeutics, and fluorescent labeling as a surrogate for subsequent radiolabeling. Despite their extensive use, one of the fundamental properties of NIR dyes, the residualization rate within cells following internalization, has not been systematically studied. This rate is required for the rational design of probes and proper interpretation of in vivo results. Procedures In this brief report, we measure the cellular residualization rate of eight commonly used dyes encompassing three core structures (cyanine, BODIPY, and oxazine/thiazine/carbopyronin). Results We identify residualizing (half-life > 24 hrs) and non-residualizing dyes (half-life < 24 hrs) in both the far red (~650-680 nm) and near infrared (~740-800 nm) regions. Conclusions This data will allow researchers to independently and rationally select the wavelength and residualizing nature of dyes for molecular imaging agent design. PMID:25869081

  4. The preparation and identification of peptide imaging agent of lung cancer

    Chu Liping; Wang Yan; Wang Yueying; Liu Jinjian; Wu Hongying; Liu Jianfeng

    2010-01-01

    Objective: To screen in vivo lung cancer specific binding 7-peptide from T7 phage display random peptide library and prepare peptide imaging agent in early in early diagnosis of lung cancer. Methods: Used phage display in vivo technology to get the 7-peptide phage that can bind the lung cancer specifically, then sequenced and synthesized 7-peptide. After being labeled by 125 I, this 7-peptide was injected into mice via vein and the distribution in the mice tumor mold was observed. Results: One 7-peptide was obtained after four rounds of screening, and the peptide could bind lung cancer tissue specifically. Metabolism of this peptide in mice was fast and imaging of lung cancer was best two hours later after injection. The distribution in vivo decreased and almost disappeared after six hours. Conclusion: This 7-peptide could be used to image and diagnose of lung cancer effectively. (authors)

  5. A new manganese-based oral contrast agent (CMC-001) for liver MRI. Pharmacological and pharmaceutical aspects

    Joergensen, Jan Troest; Rief, Matthias; Wagner, Moritz; Brismar, Torkel B.; Albiin, Nils

    2012-01-01

    Manganese is one of the most abundant metals on earth and is found as a component of more than 100 different minerals. Besides being an essential trace element in relation to the metabolic processes in the body, manganese is also a paramagnetic metal that possesses similar characteristics to gadolinium with regards to T1-weighted (T1-w) magnetic resonance imaging (MRI). Manganese, in the form of manganese (II) chloride tetrahydrate, is the active substance in a new targeted oral contrast agent, currently known as CMC-001, indicated for hepatobiliary MRI. Under physiological circumstances manganese is poorly absorbed from the intestine after oral intake, but by the use of specific absorption promoters, L-alanine and vitamin D3, it is possible to obtain a sufficiently high concentration in the liver in order to achieve a significant signal enhancing effect. In the liver manganese is exposed to a very high first-pass effect, up to 98 %, which prevents the metal from reaching the systemic circulation, thereby reducing the number of systemic side-effects. Manganese is one of the least toxic trace elements, and due to its favorable safety profile it may be an attractive alternative to gadolinium-based contrast agents for patients undergoing an MRI evaluation for liver metastases in the future. In this review the basic pharmacological and pharmaceutical aspects of this new targeted oral hepatobiliary specific contrast agent will be discussed

  6. Development of I-123 labeled angiostatin as a novel cancer imaging agent

    Lee, Kyung Han; Lee, Sang Yoon; Choe, Yearn Seong; Paik, Jin Young; Kim, Sun A; Han, Yu Mi; Kim, Byung Tae

    2000-01-01

    Since angiostatin is a promising anticancer agent that target tumor endothelial cells, it may have advantages over many current tumor imaging agents by overcoming problems such as poor delivery or multi-drug resistance. We therefore synthesized radiolabeled agniostatin and tested it in vivo. 123 -angiostatin was synthesized using the Bolton Hunter method. 123 I labeled plasminogen lysin-binding-site (LBS) was also synthesized. Blood clearance of he radiotracer was measured in SD rats, while tissue distribution was assessed in ICR mice at 1,4, and 18 hr. Pinhole scintigraphy was performed in SD rats and in nude mice bearing RR 1022 tumors at various time points. Radiochemical yield of 123 I-angiostatin approximated 20%. In vivo distribution demonstrated stability of the label for at least 20 hr. 123 I-angiostatin was cleared from the circulation in a biexponential manner with rapid early clearance followed by a slower rate of elimination Tissue distribution in mice showed the highest uptake in the kidneys which was the major route of excretion. This was followed by the lung, liver, and myocardium whose uptake of 1.5∼2% ID/gm at 1 hrs gradually decreased over time (all p 123 I-angiostatin and 123 I-LBS images in SD rates showed a similar distribution. Blood pool activity gradually cleared while tumor uptake increased over time, resulting in a high tumor to non tumor ratio at 20 hr. 123 I-angiostatin has promising potential as a new tumor imaging agent. Further study is warranted to assess its mechanism of uptake and precise role in cancer imaging

  7. Magnetic resonance imaging of osteosarcoma using a bis(alendronate)-based bone-targeted contrast agent.

    Ge, Pingju; Sheng, Fugeng; Jin, Yiguang; Tong, Li; Du, Lina; Zhang, Lei; Tian, Ning; Li, Gongjie

    2016-12-01

    Magnetic resonance (MR) is currently used for diagnosis of osteosarcoma but not well even though contrast agents are administered. Here, we report a novel bone-targeted MR imaging contrast agent, Gd 2 -diethylenetriaminepentaacetate-bis(alendronate) (Gd 2 -DTPA-BA) for the diagnosis of osteosarcoma. It is the conjugate of a bone cell-seeking molecule (i.e., alendronate) and an MR imaging contrast agent (i.e., Gd-DTPA). Its physicochemical parameters were measured, including pK a , complex constant, and T 1 relaxivity. Its bone cell-seeking ability was evaluated by measuring its adsorption on hydroxyapatite. Hemolysis was investigated. MR imaging and biodistribution of Gd 2 -DTPA-BA and Gd-DTPA were studied on healthy and osteosarcoma-bearing nude mice. Gd 2 -DTPA-BA showed high adsorption on hydroxyapatite, the high MR relaxivity (r 1 ) of 7.613mM -1 s -1 (2.6 folds of Gd-DTPA), and no hemolysis. The MR contrast effect of Gd 2 -DTPA-BA was much higher than that of Gd-DTPA after intravenous injection to the mice. More importantly, the MR imaging of osteosarcoma was significantly improved by Gd 2 -DTPA-BA. The signal intensity of Gd 2 -DTPA-BA reached 120.3% at 50min, equal to three folds of Gd-DTPA. The bone targeting index (bone/blood) of Gd 2 -DTPA-BA in the osteosarcoma-bearing mice was very high to 130 at 180min. Furthermore, the contrast enhancement could also be found in the lung due to metastasis of osteosarcoma. Gd 2 -DTPA-BA plays a promising role in the diagnoses of osteosacomas, including the primary bone tumors and metastases. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Ultrasound enhanced delivery of molecular imaging and therapeutic agents in Alzheimer's disease mouse models.

    Scott B Raymond

    Full Text Available Alzheimer's disease is a neurodegenerative disorder typified by the accumulation of a small protein, beta-amyloid, which aggregates and is the primary component of amyloid plaques. Many new therapeutic and diagnostic agents for reducing amyloid plaques have limited efficacy in vivo because of poor transport across the blood-brain barrier. Here we demonstrate that low-intensity focused ultrasound with a microbubble contrast agent may be used to transiently disrupt the blood-brain barrier, allowing non-invasive, localized delivery of imaging fluorophores and immunotherapeutics directly to amyloid plaques. We administered intravenous Trypan blue, an amyloid staining red fluorophore, and anti-amyloid antibodies, concurrently with focused ultrasound therapy in plaque-bearing, transgenic mouse models of Alzheimer's disease with amyloid pathology. MRI guidance permitted selective treatment and monitoring of plaque-heavy anatomical regions, such as the hippocampus. Treated brain regions exhibited 16.5+/-5.4-fold increase in Trypan blue fluorescence and 2.7+/-1.2-fold increase in anti-amyloid antibodies that localized to amyloid plaques. Ultrasound-enhanced delivery was consistently reproduced in two different transgenic strains (APPswe:PSEN1dE9, PDAPP, across a large age range (9-26 months, with and without MR guidance, and with little or no tissue damage. Ultrasound-mediated, transient blood-brain barrier disruption allows the delivery of both therapeutic and molecular imaging agents in Alzheimer's mouse models, which should aid pre-clinical drug screening and imaging probe development. Furthermore, this technique may be used to deliver a wide variety of small and large molecules to the brain for imaging and therapy in other neurodegenerative diseases.

  9. Ferric ammonium citrate as a positive bowel contrast agent for MR imaging of the upper abdomen

    Kivelitz, D.; Taupitz, M.; Hamm, B. [Universitaetsklinikum Charite, Berlin (Germany). Inst. fuer Radiologie; Gehl, H.B. [Medizinische Univ. Luebeck (Germany). Inst. fuer Radiologie; Heuck, A. [Muenchen Univ. (Germany). Radiologische Klinik; Krahe, T. [Koeln Univ. (Germany). Inst. fuer Radiologische Diagnostik; Lodemann, K.P. [Bracco-Byk Gulden GmbH, Konstanz (Germany)

    1999-07-01

    Purpose: To evaluate the safety and diagnostic efficacy of two different doses of ferric ammonium citrate as a paramagnetic oral contrast agent for MR imaging of the upper abdomen. Material and methods: Ninety-nine adult patients referred for MR imaging for a known or suspected upper abdominal pathology were included in this randomized multicenter double-blind clinical trial. Imaging was performed with spin-echo (T1- and T2-weighted) and gradient-echo (T1-weighted) techniques before and after administration of either 1200 mg or 2400 mg of ferric ammonium citrate dissolved in 600 ml of water. Safety analysis included monitoring of vital signs, assessment of adverse events, and laboratory testing. Efficacy with regard to organ distension, contrast distribution, bowel enhancement and delineation of adjacent structures was graded qualitatively. Results: No serious adverse events were reported for either of the two concentrations. A total of 31 minor side effects were noted, of which significantly more occurred in the higher dose group (p<0.01). The diagnostic confidence in defining or excluding disease was graded as better after contrast administration for 48% of all images. Marked or moderate enhancement of the upper gastrointestinal tract was achieved at both doses in 69.5% of cases with no evident difference between the two doses. The higher dose tended to show better results in terms of the contrast assessment parameters. Conclusion: Ferric ammonium citrate is a safe and effective oral contrast agent for MR imaging of the upper abdomen at two different dose levels. The higher dose showed a tendency toward better imaging results while the lower dose caused significantly fewer side effects. Therefore, the 1200 mg dose can be recommended in view of the risk-to-benefit ratio. (orig.)

  10. Thermal dependence of ultrasound contrast agents scattering efficiency for echographic imaging techniques

    Biagioni, Angelo; Bettucci, Andrea; Passeri, Daniele; Alippi, Adriano

    2015-06-01

    Ultrasound contrast agents are used in echographic imaging techniques to enhance image contrast. In addition, they may represent an interesting solution to the problem of non-invasive temperature monitoring inside the human body, based on some thermal variations of their physical properties. Contrast agents, indeed, are inserted into blood circulation and they reach the most important organs inside the human body; consequently, any thermometric property that they may possess, could be exploited for realizing a non-invasive thermometer. They essentially are a suspension of microbubbles containing a gas enclosed in a phospholipid membrane; temperature variations induce structural modifications of the microbubble phospholipid shell, thus causing thermal dependence of contrast agent's elastic characteristics. In this paper, the acoustic scattering efficiency of a bulk suspension of of SonoVue® (Bracco SpA Milan, Italy) has been studied using a pulse-echo technique in the frequency range 1-17 MHz, as it depends upon temperatures between 25 and 65°C. Experimental data confirm that the ultrasonic attenuation coefficient of SonoVue® depends on temperature between 25 and 60°C. Chemical composition of the bubble shell seem to support the hypothesis that a phase transition in the microstructure of lipid-coated microbubbles could play a key role in explaining such effect.

  11. ESGAR consensus statement on liver MR imaging and clinical use of liver-specific contrast agents

    Neri, E.; Boraschi, P.; Bartolozzi, C. [University of Pisa, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Bali, M.A.; Matos, C. [Hopital Erasme, MRI Clinics, Department of Radiology, Bruxelles (Belgium); Ba-Ssalamah, A. [The General Hospital of the Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Brancatelli, G. [University of Palermo, Department of Radiology, Palermo (Italy); Alves, F.C. [University Hospital of Coimbra, Medical Imaging Department and Faculty of Medicine, Coimbra (Portugal); Grazioli, L. [Spedali Civili di Brescia, Department of Radiology, Brescia (Italy); Helmberger, T. [Academic Teaching Hospital of the Technical University, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Klinikum Bogenhausen, Munich (Germany); Lee, J.M. [Seoul National University College of Medicine, Division of Abdominal Imaging, Department of Radiology, Seoul (Korea, Republic of); Manfredi, R. [University of Verona, Department of Radiology, Verona (Italy); Marti-Bonmati, L. [Hospital Universitario y Politecnico La Fe, Area Clinica de Imagen Medica, Valencia (Spain); Merkle, E.M. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Op De Beeck, B. [Antwerp University Hospital, Department of Radiology, Edegem (Belgium); Schima, W. [KH Goettlicher Heiland, Krankenhaus der Barmherzigen Schwestern and Sankt Josef-Krankenhaus, Department of Diagnostic and Interventional Radiology, Vienna (Austria); Skehan, S. [St Vincent' s University Hospital, Department of Radiology, Dublin (Ireland); Vilgrain, V. [Assistance Publique-Hopitaux de Paris, APHP, Hopital Beaujon, Radiology Department, Clichy, Paris (France); Zech, C. [Universitaetsspital Basel, Abteilungsleiter Interventionelle Radiologie, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland)

    2016-04-15

    To develop a consensus and provide updated recommendations on liver MR imaging and the clinical use of liver-specific contrast agents. The European Society of Gastrointestinal and Abdominal Radiology (ESGAR) formed a multinational European panel of experts, selected on the basis of a literature review and their leadership in the field of liver MR imaging. A modified Delphi process was adopted to draft a list of statements. Descriptive and Cronbach's statistics were used to rate levels of agreement and internal reliability of the consensus. Three Delphi rounds were conducted and 76 statements composed on MR technique (n = 17), clinical application of liver-specific contrast agents in benign, focal liver lesions (n = 7), malignant liver lesions in non-cirrhotic (n = 9) and in cirrhotic patients (n = 18), diffuse and vascular liver diseases (n = 12), and bile ducts (n = 13). The overall mean score of agreement was 4.84 (SD ±0.17). Full consensus was reached in 22 % of all statements in all working groups, with no full consensus reached on diffuse and vascular diseases. The consensus provided updated recommendations on the methodology, and clinical indications, of MRI with liver specific contrast agents in the study of liver diseases. (orig.)

  12. An agent harms a victim: A functional magnetic resonance imaging study on specific moral emotions

    Kedia, G.; Kedia, G.; Martinot, J.L.; Kedia, G.; Martinot, J.L.; Kedia, G.; Hilton, D.; Berthoz, S.; Wessa, M.

    2008-01-01

    The statement 'An agent harms a victim' depicts a situation that triggers moral emotions. Depending on whether the agent and the victim are the self or someone else, it can lead to four different moral emotions: self-anger ('I harm myself'), guilt ('I harm someone'), other-anger ('someone harms me'), and compassion ('someone harms someone'). In order to investigate the neural correlates of these emotions, we examined brain activation patterns elicited by variations in the agent (self vs. other) and the victim (self vs. other) of a harmful action. Twenty-nine healthy participants underwent functional magnetic resonance imaging while imagining being in situations in which they or someone else harmed themselves or someone else. Results indicated that the three emotional conditions associated with the involvement of other, either as agent or victim (guilt, other-anger, and compassion conditions), all activated structures that have been previously associated with the Theory of Mind (ToM, the attribution of mental states to others), namely, the dorsal medial prefrontal cortex, the precuneus, and the bilateral temporo-parietal junction. Moreover, the two conditions in which both the self and other were concerned by the harmful action (guilt and other-anger conditions) recruited emotional structures (i. e., the bilateral amygdala, anterior cingulate, and basal ganglia). These results suggest that specific moral emotions induce different neural activity depending on the extent to which they involve the self and other. (authors)

  13. Development of 99Tcm-Q3 as a new type myocardial perfusion imaging agent

    Li Yunchun; Tan Tianzhi; Fan Chengzhong; Zhao Keqing; Wei Xihe; Li Quan

    1999-01-01

    Objective: To develop 99 Tc m -N,N'-ethylene-bis (acetylacetone iminato) bis [tris (3-methoxy-1-propyl) phosphine] ( 99 Tc m -Q 3 ) as a new type of myocardial perfusion imaging agent. Methods: After N,N'-ethylene-bis (acetylacetone iminato) and tris (3-methoxy-1-propyl) phosphine were made, N,N'-ethylene-bis (acetylacetone iminato) was labelled using reduced 99 Tc m O 4 - by SnCl 2 ·2H 2 O under the presence of alkali, then tris (3-methoxy-1-propyl) phosphine was added and reacted for ten minutes, 99 Tc m -Q 3 was obtained at the end. Biodistribution in mice, in vitro stability and acute toxicity of 99 Tc m -Q 3 were examined. Results: 99 Tc m -Q 3 was taken up rapidly by the heart, and the uptake rate was very high, by 5 minutes post injection, 24.66% of the injected dose was taken up in per gram heart, and no significant washout was shown up by 4 hours. But 99 Tc m -Q 3 was cleaned out rapidly from blood, lung and liver. No poisonousness and adverse effects were observed, and its stability lasted more than 6 hours. Conclusions: 99 Tc m -Q 3 is a fairly good myocardial perfusion imaging agent for improving the quality of myocardial perfusion imaging

  14. Magnetic resonance imaging using paramagnetic contrast agents in the clinical evaluation of myocardial infarction. Chapter 15

    Dijkman, P.R.M. van; Wall, E.E. van der

    1992-01-01

    MRI is noninvasive and specific method for production of high resolution tomographic images in blocks of 3D information. Apart from scintigraphic techniques and computed tomography for evaluation of myocardial ischemia and infarcts, MRI has emerged as a new diagnostic technique to study the extent of anatomical and functional abnormalities in patients with coronary artery disease. Conventional noncontrast MRI can identify acute-infarcted myocardial areas, although the difficulty in identifying myocardial ischemia and infarct with noncontrast MRI suggests a potential role for contrast enhanced MRI. Use of the paramagnetic contrast agent gadolinium diethylene triamine pentaacetic acid (Gd-DTPA) improves depiction of infarcted myocardium on T1-weighted spin -echo MR images that are obtained soon after acute myocardial infarction. This is of particular interest for the estimation of myocardial infarct size. Furthermore, ultrafast subsecond imaging, in combination with Gd-DTPA, offers the potential to analyze cardiac first pass and myocardial perfusion. The development of nontoxic paramagnetic contrast agents which are selectively taken up by viable myocardium would be helpful in assessing the presence of ischemic/infarcted myocardium salvage by MRI following reperfusion. (author). 58 refs., 6 figs

  15. Lanthanide Phytanates: Liquid-Crystalline Phase Behavior, Colloidal Particle Dispersions, and Potential as Medical Imaging Agents

    Conn, Charlotte E.; Panchagnula, Venkateswarlu; Weerawardena, Asoka; Waddington, Lynne J.; Kennedy, Danielle F.; Drummond, Calum J. (CSIRO/MHT); (CSIRO/MSE)

    2010-08-23

    Lanthanide salts of phytanic acid, an isoprenoid-type amphiphile, have been synthesized and characterized. Elemental analysis and FTIR spectroscopy were used to confirm the formed product and showed that three phytanate anions are complexed with one lanthanide cation. The physicochemical properties of the lanthanide phytanates were investigated using DSC, XRD, SAXS, and cross-polarized optical microscopy. Several of the hydrated salts form a liquid-crystalline hexagonal columnar mesophase at room temperature, and samarium(III) phytanate forms this phase even in the absence of water. Select lanthanide phytanates were dispersed in water, and cryo-TEM images indicate that some structure has been retained in the dispersed phase. NMR relaxivity measurements were conducted on these systems. It has been shown that a particulate dispersion of gadolinium(III) phytanate displays proton relaxivity values comparable to those of a commercial contrast agent for magnetic resonance imaging and a colloidal dispersion of europium(III) phytanate exhibits the characteristics of a fluorescence imaging agent.

  16. Lanthanide Phytanates: Liquid-Crystalline Phase Behavior, Colloidal Particle Dispersions, and Potential as Medical Imaging Agents

    Conn, Charlotte E.; Panchagnula, Venkateswarlu; Weerawardena, Asoka; Waddington, Lynne J.; Kennedy, Danielle F.; Drummond, Calum J.

    2010-01-01

    Lanthanide salts of phytanic acid, an isoprenoid-type amphiphile, have been synthesized and characterized. Elemental analysis and FTIR spectroscopy were used to confirm the formed product and showed that three phytanate anions are complexed with one lanthanide cation. The physicochemical properties of the lanthanide phytanates were investigated using DSC, XRD, SAXS, and cross-polarized optical microscopy. Several of the hydrated salts form a liquid-crystalline hexagonal columnar mesophase at room temperature, and samarium(III) phytanate forms this phase even in the absence of water. Select lanthanide phytanates were dispersed in water, and cryo-TEM images indicate that some structure has been retained in the dispersed phase. NMR relaxivity measurements were conducted on these systems. It has been shown that a particulate dispersion of gadolinium(III) phytanate displays proton relaxivity values comparable to those of a commercial contrast agent for magnetic resonance imaging and a colloidal dispersion of europium(III) phytanate exhibits the characteristics of a fluorescence imaging agent.

  17. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis

    Didier, Ryne A.; Hopkins, Katharine L.; Coakley, Fergus V.; Foster, Bryan R. [Oregon Health and Science University, Department of Diagnostic Radiology, Portland, OR (United States); Krishnaswami, Sanjay [Oregon Health and Science University, Department of Surgery, Portland, OR (United States); Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States); Spiro, David M. [Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States)

    2017-09-15

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall

  18. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis

    Didier, Ryne A.; Hopkins, Katharine L.; Coakley, Fergus V.; Foster, Bryan R.; Krishnaswami, Sanjay; Spiro, David M.

    2017-01-01

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall

  19. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    Ahmad, Tanveer; Bae, Hongsub; Iqbal, Yousaf; Rhee, Ilsu; Hong, Sungwook; Chang, Yongmin; Lee, Jaejun; Sohn, Derac

    2015-01-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe 2 O 4 ) nanoparticles as both T 1 and T 2 contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T 1 and T 2 relaxivities were 0.858±0.04 and 1.71±0.03 mM −1 s −1 , respectively. In animal experimentation, both a 25% signal enhancement in the T 1 -weighted mage and a 71% signal loss in the T 2 -weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T 1 and T 2 contrast agents in MRI. We note that the applicability of our nanoparticles as both T 1 and T 2 contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles. - Highlights: • Chitosan-coated nickel-ferrite (Ni-Fe 2 O 4 ) nanoparticles were synthesized in an aqueous system by chemical co-precipitation. • The characterization of bare and chitosan-coated nanoparticles were performed using various analytical tools, such as TEM, FTIR, XRD, and VMS. • We evaluated the coated particles as potential T 1 and T 2 contrast agents for MRI by measuring T 1 and T 2 relaxation times as a function of iron concentration. • Both T 1 and T 2 effects were also observed in animal experimentation

  20. Development of a PET Prostate-Specific Membrane Antigen Imaging Agent: Preclinical Translation for Future Clinical Application

    2017-10-01

    are those of the author(s) and should not be construed as an official Department of the Army position, policy or decision unless so designated by...phase 0) application to the FDA by the end of the funding period. The small molecule imaging agents under study home to prostate specific membrane...funding period. The small molecule imaging agents under study home to prostate specific membrane antigen (PSMA) that is prevalent on a majority of

  1. Nerve-Highlighting Fluorescent Contrast Agents for Image-Guided Surgery

    Summer L. Gibbs-Strauss

    2011-03-01

    Full Text Available Nerve damage is the major morbidity of many surgeries, resulting in chronic pain, loss of function, or both. The sparing of nerves during surgical procedures is a vexing problem because surrounding tissue often obscures them. To date, systemically administered nerve-highlighting contrast agents that can be used for nerve-sparing image-guided surgery have not been reported. In the current study, physicochemical and optical properties of 4,4‘-[(2-methoxy-1,4-phenylenedi-(1E-2,1-ethenediyl]bis-benzenamine (BMB and a newly synthesized, red-shifted derivative 4-[(1E-2-[4-[(1E-2-[4-aminophenyl]ethenyl]-3-methoxyphenyl]ethenyl]-benzonitrile (GE3082 were characterized in vitro and in vivo. Both agents crossed the blood-nerve barrier and blood-brain barrier and rendered myelinated nerves fluorescent after a single systemic injection. Although both BMB and GE3082 also exhibited significant uptake in white adipose tissue, GE3082 underwent a hypsochromic shift in adipose tissue that provided a means to eliminate the unwanted signal using hyperspectral deconvolution. Dose and kinetic studies were performed in mice to determine the optimal dose and drug-imaging interval. The results were confirmed in rat and pig, with the latter used to demonstrate, for the first time, simultaneous fluorescence imaging of blood vessels and nerves during surgery using the FLARE™ (Fluorescence-Assisted Resection and Exploration imaging system. These results lay the foundation for the development of ideal nerve-highlighting fluorophores for image-guided surgery.

  2. Diagnostic value of hepatobiliary sequence scintigraphy in patients with postcholecystectomy syndrome

    Frey, H.; Jorke, D.; Gottschild, D.; Langbein, T.; Zinner, G.; Kob, D.

    1992-01-01

    The autors report about the possibility of registration from functionally disturbances of gall fluid with the help of hepatobiliary sequence-scintigraphy in patients with postcholecystectomy-syndrome. The diagnostic importance of this methode and the meaning of other usually procedures is discussed. A selection of patients succeed in objective manner with hepatobiliary sequence-scintigraphy together with clinically dates of laboratory. In patients with postcholecystectomy-syndrome the procedure can show functionally disturbances in the area of extrahepatic gall ways. (orig.) [de

  3. Chemistry of paramagnetic and diamagnetic contrast agents for Magnetic Resonance Imaging and Spectroscopy

    Perez-Mayoral, Elena; Negri, Viviana; Soler-Padros, Jordi; Cerdan, Sebastian; Ballesteros, Paloma

    2008-01-01

    We provide a brief overview of the chemistry and most relevant properties of paramagnetic and diamagnetic contrast agents (CAs) for Magnetic Resonance Imaging and Magnetic Resonance Spectroscopic Imaging. Paramagnetic CAs for MRI consist mainly of Gd(III) complexes from linear or macrocyclic polyaminopolycarboxylates. These agents reduce, the relaxation times T 1 and T 2 of the water protons in a concentration dependent manner, increasing selectively MRI contrast in those regions in which they accumulate. In most instances they provide anatomical information on the localization of lesions and in some specific cases they may allow to estimate some physiological properties of tissues including mainly vascular performance. Because of its ability to discriminate easily between normal and diseased tissue, extracellular pH (pH e ) has been added recently, to the battery of variables amenable to MRI investigation. A variety of Gd(III) containing macrocycles sensitive to pH, endogenous or exogenous polypeptides or even liposomes have been investigated for this purpose, using the pH dependence of their relaxivity or magnetization transfer rate constant (chemical exchange saturation transfer, CEST). Many environmental circumstances in addition to pH affect, however, relaxivity or magnetization transfer rate constants of these agents, making the results of pH measurements by MRI difficult to interpret. To overcome these limitations, our laboratory synthesized and developed a novel series of diamagnetic CAs for Magnetic Resonance Spectroscopic Imaging, a new family of monomeric and dimeric imidazolic derivatives able to provide unambiguous measurements of pH e , independent of water relaxivity, diffusion or exchange

  4. Chemistry of paramagnetic and diamagnetic contrast agents for Magnetic Resonance Imaging and Spectroscopy

    Perez-Mayoral, Elena [Laboratorio de Sintesis Organica e Imagen Molecular por Resonancia Magnetica, Facultad de Ciencias, UNED, Paseo Senda del Rey 9, E-28040 Madrid (Spain); Departamento de Quimica Inorganica y Quimica Tecnica, Facultad de Ciencias, UNED, Paseo Senda del Rey 9, E-28040 Madrid (Spain); Negri, Viviana; Soler-Padros, Jordi [Laboratorio de Sintesis Organica e Imagen Molecular por Resonancia Magnetica, Facultad de Ciencias, UNED, Paseo Senda del Rey 9, E-28040 Madrid (Spain); Cerdan, Sebastian [Laboratorio de Imagen Espectroscopica por Resonancia Magnetica (LIERM), Instituto de Investigaciones Biomedicas ' Alberto Sols' , CSIC/UAM, c/Arturo Duperier 4, E-28029 Madrid (Spain); Ballesteros, Paloma [Laboratorio de Sintesis Organica e Imagen Molecular por Resonancia Magnetica, Facultad de Ciencias, UNED, Paseo Senda del Rey 9, E-28040 Madrid (Spain)], E-mail: pballesteros@ccia.uned.es

    2008-09-15

    We provide a brief overview of the chemistry and most relevant properties of paramagnetic and diamagnetic contrast agents (CAs) for Magnetic Resonance Imaging and Magnetic Resonance Spectroscopic Imaging. Paramagnetic CAs for MRI consist mainly of Gd(III) complexes from linear or macrocyclic polyaminopolycarboxylates. These agents reduce, the relaxation times T{sub 1} and T{sub 2} of the water protons in a concentration dependent manner, increasing selectively MRI contrast in those regions in which they accumulate. In most instances they provide anatomical information on the localization of lesions and in some specific cases they may allow to estimate some physiological properties of tissues including mainly vascular performance. Because of its ability to discriminate easily between normal and diseased tissue, extracellular pH (pH{sub e}) has been added recently, to the battery of variables amenable to MRI investigation. A variety of Gd(III) containing macrocycles sensitive to pH, endogenous or exogenous polypeptides or even liposomes have been investigated for this purpose, using the pH dependence of their relaxivity or magnetization transfer rate constant (chemical exchange saturation transfer, CEST). Many environmental circumstances in addition to pH affect, however, relaxivity or magnetization transfer rate constants of these agents, making the results of pH measurements by MRI difficult to interpret. To overcome these limitations, our laboratory synthesized and developed a novel series of diamagnetic CAs for Magnetic Resonance Spectroscopic Imaging, a new family of monomeric and dimeric imidazolic derivatives able to provide unambiguous measurements of pH{sub e}, independent of water relaxivity, diffusion or exchange.

  5. Near-infrared light-responsive liposomal contrast agent for photoacoustic imaging and drug release applications.

    Sivasubramanian, Kathyayini; Mathiyazhakan, Malathi; Wiraja, Christian; Upputuri, Paul Kumar; Xu, Chenjie; Pramanik, Manojit

    2017-04-01

    Photoacoustic imaging has become an emerging tool for theranostic applications. Not only does it help in release and therapeutic applications. We explore near-infrared light-sensitive liposomes coated with gold nanostars (AuNSs) for both imaging and drug release applications using a photoacoustic imaging system. Being amphiphilic, the liposomes lipid bilayer and the aqueous core enable encapsulation of both hydrophobic and hydrophilic drugs. The AuNSs on the surface of the liposomes act as photon absorbers due to their intrinsic surface plasmon resonance. Upon excitation by laser light at specific wavelength, AuNSs facilitate rapid release of the contents encapsulated in the liposomes due to local heating and pressure wave formation (photoacoustic wave). Herein, we describe the design and optimization of the AuNSs-coated liposomes and demonstrate the release of both hydrophobic and hydrophilic model drugs (paclitaxel and calcein, respectively) through laser excitation at near-infrared wavelength. The use of AuNSs-coated liposomes as contrast agents for photoacoustic imaging is also explored with tissue phantom experiments. In comparison to blood, the AuNSs-coated liposomes have better contrast (approximately two times) at 2-cm imaging depth.

  6. Magnetosomes used as biogenic MRI contrast agent for molecular imaging of glioblastoma model

    Boucher, Marianne

    2016-01-01

    This work takes place in the context of molecular imaging, which aims at tailoring medical treatments and therapies to the individual context by revealing molecular or cellular phenomenon of medical interest in the less invasive manner. In particular, it can be achieved with MRI molecular imaging using engineered iron-oxide contrast agent.This PhD thesis focuses on the study of a new class of iron-oxide contrast agent for high field MRI. Indeed, magnetosomes are natural iron-oxide vesicles produced by magneto-tactic bacteria. These bacteria synthesized such magnetic vesicles and ordered them like a nano-compass in order to facilitate their navigation in sediments. This explains why magnetosomes are awarded with tremendous magnetic properties: around 50 nm, mono-crystalline, single magnetic domain and high saturation magnetization. Furthermore, a wide variety of bacterial strains exist in nature and size and shape of magnetosomes are highly stable within strain and can be very different between strains. Finally, magnetosomes are naturally coated with a bi-lipidic membrane whose content is genetically determined. Lately, researchers have unravelled magnetosomes membrane protein contents, opening the way to create functionalized magnetosomes thanks to fusion of the gene coding for a protein of interest with the gene coding for an abundant protein at magnetosomes membrane.A new alternative path using living organisms to tackle the production of engineered high efficiency molecular imaging probes have been investigated with magneto-tactic bacteria in this PhD. The production and engineering of magnetosomes have been carried out by our partner, the Laboratoire de Bio-energetique Cellulaire (LBC, CEA Cadarache), and will be presented and discussed. We then characterized magnetosomes as contrast agent for high field MRI. We showed they present very promising contrasting properties in vitro, and assessed this observation in vivo by establishing they can be used as efficient

  7. Magnetic resonance imaging with liver-specific contrast agent in primary amyloidosis and intrahepatic cholestasis

    Moeller, J.M.; Santoni-Rugiu, E.; Chabanova, E.; Logager, V.; Hansen, A.B.; Thomsen, H.S. [Depts. of Radiology and Pathology, Copenhagen Univ. Hospital, Herlev (Denmark)

    2007-02-15

    Magnetic resonance imaging (MRI) findings in hepatic amyloidosis are not well defined. Here, we report on a patient with renal failure caused by primary amyloidosis (AL type) who developed jaundice. Ultrasound and computed tomography were normal except for some ascites. MRI with oral manganese-containing contrast agent revealed several focal areas without contrast uptake in the hepatocytes and no bile secretion after 8 hours. No extrahepatic bile obstructions were found. Liver biopsy showed severe intraportal, vascular, and parenchymal amyloidosis causing severe cholestasis and atrophy of hepatocytes.

  8. Measurements of some basic constants of 68Ga(BAT-TECH) as an imaging agent

    Chen Huawei; Liu Boli

    1994-01-01

    The kinetic properties of a new myocardial imaging agent 68 Ga(BAT-TECH) are investigated and its thermodynamic constants are measured. The results are as follows: Citrate→BAT-TECH exchange reaction order is second-order; reaction rate k = 0.50 l/mol·s; activation energy E a = 56.6 kJ/mol; the stability constant of 68 Ga(BAT-TECH) lgβ = 14.9; the acid dissociation constants of BAT-TECH pK 1 = 4.62, pK 2 = 7.68, pK-3 = 8.68, pK 4 = 11.2

  9. Radiolabeled phosphonium salts as mitocondrial voltage sensors for positron emission tomography myocardial imaging agents

    Kim, Dong Yon; Min, Jung Joon [Dept. of Nuclear Medicine,Chonnam National University Medical School and Hwasun Hospital, Gwangju (Korea, Republic of)

    2016-09-15

    Despite substantial advances in the diagnosis of cardiovascular disease, {sup 18}F-labeled positron emission tomography (PET) radiopharmaceuticals remain necessary to diagnose heart disease because clinical use of current PET tracers is limited by their short half-life. Lipophilic cations such as phosphonium salts penetrate the mitochondrial membranes and accumulate in mitochondria of cardiomyocytes in response to negative inner-transmembrane potentials. Radiolabeled tetraphenyl phosphonium cation derivatives have been developed as myocardial imaging agents for PET. In this review, a general overview of these radiotracers, including their radiosynthesis, in vivo characterization, and evaluation is provided and clinical perspectives are discussed.

  10. evaluation of some technetium-99m fluoroquinolones complexes as imaging agents for bacterial inflammatory lesions

    Abdel-Kawy, O.A.A.

    2007-01-01

    in this study, the labeling method of ciprofloxacin and levofloxacin with technetium-99m and their biological evaluation in man-induced inflammation models were described . in -vitro microbiological evaluation of both complexes was also performed in order to investigate the effect of labeling on the activity and spectrum of both antibiotics. all the gathered biological data support the usefulness of 99m Tc-fluoroquinolones as infection imaging agents that could discriminate between infections and sterile inflammations. the freeze-dried form of levofloxacin kits was prepared and found to meet all the radiochemical and biological tests

  11. Imaging in Vivo Extracellular pH with a Single Paramagnetic Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agent

    Guanshu Liu

    2012-01-01

    Full Text Available The measurement of extracellular pH (pHe has potential utility for cancer diagnoses and for assessing the therapeutic effects of pH-dependent therapies. A single magnetic resonance imaging (MRI contrast agent that is detected through paramagnetic chemical exchange saturation transfer (PARACEST was designed to measure tumor pHe throughout the range of physiologic pH and with magnetic resonance saturation powers that are not harmful to a mouse model of cancer. The chemical characterization and modeling of the contrast agent Yb3+-1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid, 10-o-aminoanilide (Yb-DO3A-oAA suggested that the aryl amine of the agent forms an intramolecular hydrogen bond with a proximal carboxylate ligand, which was essential for generating a practical chemical exchange saturation transfer (CEST effect from an amine. A ratio of CEST effects from the aryl amine and amide was linearly correlated with pH throughout the physiologic pH range. The pH calibration was used to produce a parametric pH map of a subcutaneous flank tumor on a mouse model of MCF-7 mammary carcinoma. Although refinements in the in vivo CEST MRI methodology may improve the accuracy of pHe measurements, this study demonstrated that the PARACEST contrast agent can be used to generate parametric pH maps of in vivo tumors with saturation power levels that are not harmful to a mouse model of cancer.

  12. Imaging Primary Mouse Sarcomas After Radiation Therapy Using Cathepsin-Activatable Fluorescent Imaging Agents

    Cuneo, Kyle C. [Department of Radiation Oncology, Duke University School of Medicine, Durham, North Carolina (United States); Mito, Jeffrey K.; Javid, Melodi P. [Department of Pharmacology and Cancer Biology, Duke University School of Medicine, Durham, North Carolina (United States); Ferrer, Jorge M. [Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Kim, Yongbaek [Department of Clinical Pathology, College of Veterinary Medicine, Seoul National University, Seoul (Korea, Republic of); Lee, W. David [The David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Bawendi, Moungi G. [Department of Chemistry, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Brigman, Brian E. [Department of Orthopedic Surgery, Duke University School of Medicine, Durham, North Carolina (United States); Kirsch, David G., E-mail: david.kirsch@duke.edu [Department of Radiation Oncology, Duke University School of Medicine, Durham, North Carolina (United States); Department of Pharmacology and Cancer Biology, Duke University School of Medicine, Durham, North Carolina (United States)

    2013-05-01

    Purpose: Cathepsin-activated fluorescent probes can detect tumors in mice and in canine patients. We previously showed that these probes can detect microscopic residual sarcoma in the tumor bed of mice during gross total resection. Many patients with soft tissue sarcoma (STS) and other tumors undergo radiation therapy (RT) before surgery. This study assesses the effect of RT on the ability of cathepsin-activated probes to differentiate between normal and cancerous tissue. Methods and Materials: A genetically engineered mouse model of STS was used to generate primary hind limb sarcomas that were treated with hypofractionated RT. Mice were injected intravenously with cathepsin-activated fluorescent probes, and various tissues, including the tumor, were imaged using a hand-held imaging device. Resected tumor and normal muscle samples were harvested to assess cathepsin expression by Western blot. Uptake of activated probe was analyzed by flow cytometry and confocal microscopy. Parallel in vitro studies using mouse sarcoma cells were performed. Results: RT of primary STS in mice and mouse sarcoma cell lines caused no change in probe activation or cathepsin protease expression. Increasing radiation dose resulted in an upward trend in probe activation. Flow cytometry and immunofluorescence showed that a substantial proportion of probe-labeled cells were CD11b-positive tumor-associated immune cells. Conclusions: In this primary murine model of STS, RT did not affect the ability of cathepsin-activated probes to differentiate between tumor and normal muscle. Cathepsin-activated probes labeled tumor cells and tumor-associated macrophages. Our results suggest that it would be feasible to include patients who have received preoperative RT in clinical studies evaluating cathepsin-activated imaging probes.

  13. Gadoxetate Acid-Enhanced MR Imaging for HCC: A Review for Clinicians

    Jendana Chanyaputhipong

    2011-01-01

    Full Text Available Hepatocellular carcinoma (HCC is increasingly being detected at an earlier stage, owing to the screening programs and regular imaging follow-up in high-risk populations. Small HCCs still pose diagnostic challenges on imaging due to decreased sensitivity and increased frequency of atypical features. Differentiating early HCC from premalignant or benign nodules is important as management differs and has implications on both the quality of life and the overall survival for the patients. Gadoxetate acid (Gd-EOB-DTPA, Primovist®, Bayer Schering Pharma is a relatively new, safe and well-tolerated liver-specific contrast agent for magnetic resonance (MR imaging of the liver that has combined perfusion- and hepatocyte-specific properties, allowing for the acquisition of both dynamic and hepatobiliary phase images. Its high biliary uptake and excretion improves lesion detection and characterization by increasing liver-to-lesion conspicuity in the added hepatobiliary phase imaging. To date, gadoxetate acid-enhanced MRI has been mostly shown to be superior to unenhanced MRI, computed tomography, and other types of contrast agents in the detection and characterization of liver lesions. This review article focuses on the evolving role of gadoxetate acid in the characterization of HCC, differentiating it from other mimickers of HCC.

  14. A Potential Dubin-Johnson Syndrome Imaging Agent: Synthesis, Biodistribution, and MicroPET Imaging

    Jeongsoo Yoo

    2005-01-01

    Full Text Available Dubin-Johnson syndrome (DJS is caused by a deficiency of the human canalicular multispecific organic anion transporter (cMOAT. A new lipophilic copper-64 complex of 1,4,7-tris(carboxymethyl-10-(tetradecyl-1,4,7,10-tetraazadodecane (5 was prepared and evaluated for potential as a diagnostic tool for DJS. The prepared ligand was labeled with 64Cu citrate in high radiochemical purity. In vivo uptake and clearance of the complex was determined through biodistribution studies using normal Sprague-Dawley rats and mutant cMOAT-deficient (TR− rats. In normal rats, the radioactive copper complex was cleared quickly from the body exclusively through the hepatic pathway. The 64Cu complex was taken up rapidly by the liver and quickly excreted into the small intestine and then the upper large intestine, whereas < 1% ID/organ was found in the kidney at all time points post injection. Whereas activity was accumulated continuously in the liver of TR− rats, it was not excreted into the small intestine. MicroPET studies of normal and TR rats were consistent with biodistribution data and showed dramatically different images. This study strongly suggests that cMOAT is involved in excretion of 64Cu-5. The significant difference between the biodistribution data and microPET images of the normal and TR− rats demonstrates that this new 64Cu complex may allow noninvasive diagnosis of DJS in humans.

  15. Cellular MR Imaging

    Michel Modo

    2005-07-01

    Full Text Available Cellular MR imaging is a young field that aims to visualize targeted cells in living organisms. In order to provide a different signal intensity of the targeted cell, they are either labeled with MR contrast agents in vivo or prelabeled in vitro. Either (ultrasmall superparamagnetic iron oxide [(USPIO] particles or (polymeric paramagnetic chelates can be used for this purpose. For in vivo cellular labeling, Gd3+- and Mn2+- chelates have mainly been used for targeted hepatobiliary imaging, and (USPIO-based cellular imaging has been focused on imaging of macrophage activity. Several of these magneto-pharmaceuticals have been FDA-approved or are in late-phase clinical trials. As for prelabeling of cells in vitro, a challenge has been to induce a sufficient uptake of contrast agents into nonphagocytic cells, without affecting normal cellular function. It appears that this issue has now largely been resolved, leading to an active research on monitoring the cellular biodistribution in vivo following transplantation or transfusion of these cells, including cell migration and trafficking. New applications of cellular MR imaging will be directed, for instance, towards our understanding of hematopoietic (immune cell trafficking and of novel guided (stem cell-based therapies aimed to be translated to the clinic in the future.

  16. A new myocardial imaging agent: Synthesis, characterization, and biodistribution of gallium-68-BAT-TECH

    Kung, H.F.; Liu, B.L.; Mankoff, D.; Kung, M.P.; Billings, J.J.; Francesconi, L.; Alavi, A.

    1990-01-01

    In order to develop a new myocardial perfusion agent for positron emission tomography (PET), a new lipid-soluble gallium complex was evaluated. Synthesis, radiolabeling, characterization, and biodistribution of a unique gallium complex, [ 67 Ga]BAT-TECH (bis-aminoethanethiol-tetraethyl-cyclohexyl), are described. The complex formation between Ga+3 and BAT-TECH ligand is simple, rapid, and of high yield (greater than or equal to 95%). This process is amenable to kit formulation. The complex has a net charge of +1 and a Ga/ligand ratio of 1:1. Biodistribution in rats shows high uptake in the heart as well as in the liver. When [ 68 Ga] BAT-TECH was injected into a monkey, the heart and liver are clearly delineated by PET imaging, suggesting that this complex may be a possible tracer for myocardial perfusion imaging

  17. Synthesis of opioid receptor imaging agent 7α-o-IA-DPN

    Wang Rongfu

    1997-01-01

    A new opioid receptor imaging agent is designed and synthesized. 7α-o-iodoallyl diprenorphine (7α-o-IA-DPN) was obtained in one step by radioiododestannylation, which involved in the selection of DPN as an opioid antagonist, the regioselective protection of the DPN phenol tertiary-OH using acetylation and the introduction of vinylstannane as prosthetic group into the tertiary alcohol group position in the 7α-side chain. The iodinated DPN derivation was possessed of high radiolabeled yield (>90%) with 80 TBq/mmol specific radioactivity and more than 95% radiochemical purity. In vitro opioid receptor binding analysis showed very high affinity (Ki = 0.4 nmol/L). This new radioiodinated opioid ligand is suitable for SPECT study of opioid receptor imaging

  18. Development of NMR imaging using CEST agents: application to brain tumor in a rodent model

    Flament, J.

    2012-01-01

    The study aimed at developing saturation transfer imaging of lipoCEST contrast agents for the detection of angiogenesis in a U87 mouse brain tumor model. A lipoCEST with a sensitivity threshold of 100 pM in vitro was optimized in order to make it compatible with CEST imaging in vivo. Thanks to the development of an experimental setup dedicated to CEST imaging, we evaluated lipoCEST to detect specifically tumor angiogenesis. We demonstrated for the first time that lipoCEST visualization was feasible in vivo in a mouse brain after intravenous injection. Moreover, the integrin α v β 3 over expressed during tumor angiogenesis can be specifically targeted using a functionalized lipoCEST with RGD peptide. The specific association between the RGD-lipoCEST and its target α v β 3 was confirmed by immunohistochemical data and fluorescence microscopy. Finally, in order to tend to a molecular imaging protocol by CEST-MRI, we developed a quantification tool of lipoCEST contrast agents. This tool is based on modeling of proton exchange processes in vivo. By taking into account both B0 and B1 fields inhomogeneities which can dramatically alter CEST contrast, we showed that the accuracy of our quantification tool was 300 pM in vitro. The tool was applied on in vivo data acquired on the U87 mouse model and the maximum concentration of RGD-lipoCEST linked to their molecular targets was evaluated to 1.8 nM. (author) [fr

  19. Complications from the use of intravenous gadolinium-based contrast agents for magnetic resonance imaging

    Elias Junior, Jorge; Santos, Antonio Carlos dos; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Koenigkam-Santos, Marcel [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Centro de Ciencias das Imagens e Fisica Medica]. E-mail: jejunior@fmrp.usp.br

    2008-07-15

    Gadolinium-based contrast agents are much safer than the iodinated ones; however complications may occur and should be recognized for appropriate orientation and management. The total incidence of adverse reactions to contrast agents in magnetic resonance imaging ranges between 2% and 4%. Cases of severe acute reactions to gadolinium, such as laryngospasm and anaphylactic shock, are rare. Chronic complications secondary to the use of gadolinium also can occur and, recently an association between its use and a rare dermatologic disease occurring in patients with renal failure has been reported. Nephrogenic systemic fibrosis was the subject of an official health notification issued by the American Food and Drug Administration. This progressive disease is characterized by hardened skin with fibrotic nodules and plaques which may involve other parts of the body. Patients who have been affected by this disorder presented chronic renal failure, with metabolic acidosis and had been submitted to magnetic resonance angiography, probably involving exposure to large amounts of intravenous paramagnetic contrast. This review is aimed at presenting a succinct description of the gadolinium-based contrast agent types, possible secondary complications, their preventive measures and management. (author)

  20. PEGylated chitosan grafted with polyamidoaminedendron as tumor-targeted magnetic resonance imaging contrast agent

    Guangyue Zu; Xiaoyan Tong; Yi Cao; Ye Kuang; Yajie Zhang; Min Liu; Renjun Pei

    2017-01-01

    Macromolecular contrast agents labeled with targeting ligands are now receiving growing interest in tumor-targeted magnetic resonance imaging. In this study, a macromolecular contrast agent based on PEGylated chitosan was synthesized and characterized, and its application as an MRI contrast agent was then demonstrated both in vitro and in vivo. First, the chitosan backbone was partially grafted with poly(ethylene glycol), which was used to improve the in vivo stability, followed by modifying with azide groups. Second, alkynyl-terminated PAMAM dendron modified with gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) was synthesized and conjugated onto the chitosan backbone through click chemistry. Finally, the obtained mCA was further functionalized with folic acid to improve the target specificity. The obtained FA labeled mCA exhibited higher relaxivity (9.53 mM"-"1.s"-"1) relative to Gd-DTPA (4.25 mM"-"1.s"-"1) and showed negligible toxicity as determined by the WST assay. In vivo MRI results suggested that a relatively high signal enhancement was observed in the tumor region, which made it a promising candidate for tumor-targeted MRI CA. (authors)

  1. Preparation, purification and primary bioevaluation of radioiodinated ofloxacin. An imaging agent

    Kandil, Shaban; Seddik, Usama; Hussien, Hiba; Shaltot, Mohamed; El-Tabl, Abdou

    2015-01-01

    The broad-spectrum antibiotic agents have been demonstrated as promising diagnostic tools for early detection of infectious lesions. We set out ofloxacin (Oflo), a second-generation fluoroquinolone, for the radioiodination process. In particular, this was carried out with 125 I via an electrophilic substitution reaction. The radiochemical yield was influenced by different factors; drug concentration, different oxidizing agents, e.g. chloramine-T, iodogen and n-bromosuccinimide, pH of medium, reaction time, temperature and different organic media. These parameters were studied to optimize the best conditions for labeling with ofloxacin. We found that radiolabeling in ethanol medium showed a 70% radiochemical yield of 125 I-ofloxacin. The radioiodination was determined by means of TLC and HPLC. The cold labeled Oflo ( 127 I-Oflo) was prepared and controlled by HPLC. The cold labeled Oflo was also confirmed by NMR and MS techniques. Furthermore, biodistribution studies for labeled 125 I-Oflo were examined in two independent groups (3 mice in each one); control and E. Coli-injected (inflamed). The radiotracer showed a good localization in muscle of thigh for inflamed group as compared to control. In conclusion, ofloxacine might be a promising target as an anti-inflammatory imaging agent.

  2. Preparation, purification and primary bioevaluation of radioiodinated ofloxacin. An imaging agent

    Kandil, Shaban; Seddik, Usama; Hussien, Hiba; Shaltot, Mohamed [Atomic Energy Authority, Cairo (Egypt). Cyclotron Project; El-Tabl, Abdou [Monofia Univ. (Egypt). Faculty of Science

    2015-07-01

    The broad-spectrum antibiotic agents have been demonstrated as promising diagnostic tools for early detection of infectious lesions. We set out ofloxacin (Oflo), a second-generation fluoroquinolone, for the radioiodination process. In particular, this was carried out with {sup 125}I via an electrophilic substitution reaction. The radiochemical yield was influenced by different factors; drug concentration, different oxidizing agents, e.g. chloramine-T, iodogen and n-bromosuccinimide, pH of medium, reaction time, temperature and different organic media. These parameters were studied to optimize the best conditions for labeling with ofloxacin. We found that radiolabeling in ethanol medium showed a 70% radiochemical yield of {sup 125}I-ofloxacin. The radioiodination was determined by means of TLC and HPLC. The cold labeled Oflo ({sup 127}I-Oflo) was prepared and controlled by HPLC. The cold labeled Oflo was also confirmed by NMR and MS techniques. Furthermore, biodistribution studies for labeled {sup 125}I-Oflo were examined in two independent groups (3 mice in each one); control and E. Coli-injected (inflamed). The radiotracer showed a good localization in muscle of thigh for inflamed group as compared to control. In conclusion, ofloxacine might be a promising target as an anti-inflammatory imaging agent.

  3. Characterization of image heterogeneity using 2D Minkowski functionals increases the sensitivity of detection of a targeted MRI contrast agent.

    Canuto, Holly C; McLachlan, Charles; Kettunen, Mikko I; Velic, Marko; Krishnan, Anant S; Neves, Andre' A; de Backer, Maaike; Hu, D-E; Hobson, Michael P; Brindle, Kevin M

    2009-05-01

    A targeted Gd(3+)-based contrast agent has been developed that detects tumor cell death by binding to the phosphatidylserine (PS) exposed on the plasma membrane of dying cells. Although this agent has been used to detect tumor cell death in vivo, the differences in signal intensity between treated and untreated tumors was relatively small. As cell death is often spatially heterogeneous within tumors, we investigated whether an image analysis technique that parameterizes heterogeneity could be used to increase the sensitivity of detection of this targeted contrast agent. Two-dimensional (2D) Minkowski functionals (MFs) provided an automated and reliable method for parameterization of image heterogeneity, which does not require prior assumptions about the number of regions or features in the image, and were shown to increase the sensitivity of detection of the contrast agent as compared to simple signal intensity analysis. (c) 2009 Wiley-Liss, Inc.

  4. New 68Ga-PhenA bisphosphonates as potential bone imaging agents

    Wu, Zehui; Zha, Zhihao; Choi, Seok Rye; Plössl, Karl; Zhu, Lin; Kung, Hank F.

    2016-01-01

    Introduction: In vivo positron emission tomography (PET) imaging of the bone using [ 68 Ga]bisphosphonates may be a valuable tool for cancer diagnosis and monitoring therapeutic treatment. We have developed new [ 68 Ga]bisphosphonates based on the chelating group, AAZTA (6-[bis(hydroxycarbonyl-methyl)amino]-1,4-bis(hydroxycarbonyl methyl)-6-methylperhydro-1,4-diazepine). Method: Phenoxy derivative of AAZTA (2,2′-(6-(bis(carboxymethyl)amino)-6-((4-(2-carboxyethyl)phenoxy) methyl)-1,4-diazepane-1,4-diyl)diacetic acid), PhenA, 2, containing a bisphosphonate group (PhenA-BPAMD, 3, and PhenA-HBP, 4) was prepared. Labeling of these chelating agents with 68 Ga was evaluated. Results: The ligands reacted rapidly in a sodium acetate buffer with [ 68 Ga]GaCl 3 eluted from a commercially available 68 Ge/ 68 Ga generator (pH 4, > 95% labeling at room temperature in 5 min) to form [ 68 Ga]PhenA-BPAMD, 3, and [ 68 Ga]PhenA-HBP, 4. The improved labeling condition negates the need for further purification. The 68 Ga bisphosphonate biodistribution and autoradiography of bone sections in normal mice after an iv injection showed excellent bone uptake. Conclusion: New 68 Ga labeled bisphosphonates may be useful as in vivo bone imaging agents in conjunction with positron emission tomography (PET).

  5. Preparation and evaluation of (131I)AgI particles: potential lungs perfusion imaging agent

    Chattopadhyay, Sankha; Das, Sujata Saha; Sinha, Samarendu; Sarkar, Bharat Ranjan; Ganguly, Shantanu; Chandra, Susmita; De, Kakali; Mishra, Mridula

    2010-01-01

    Since the discovery of iodine-131 (t 1/2 : 8 d) by Livingood and Seaborg (1938), this, and other radioisotopes of iodine, have found widespread use in nuclear medicine. The purpose of the present work was to formulate Ag 131 I particles and bio-evaluate the same. The Ag 131 I particles were prepared in acidic condition having 100% R.C. Purity. The biological evaluation of Ag 131 1 particles was made by injecting about 111-185 MBq of Ag 131 I particles preparations in female albino rabbits (2-2.5 kg weight) intravenously by femoral vein under urethane anesthesia. Imaging studies were performed under Gamma Camera. The entire amount of the Ag 131 I particles were found to deposit in the lungs and remained there almost unchanged for a certain period of time after the intervenous administration. The images showed excellent, uniform lung uptake with no interference from liver and spleen to the lower regions of right and left lobes. It showed a high accumulation in the rabbits lungs (>99%) and remained constant for at least for 20 min. It is also worthy to study with 123 I/ 124 I labelled AgI for lung imaging study. In conclusion, the synthetic radiopharmaceutical ( 131 I)-Silver iodide colloid can be prepared with a large particle size, in a simple and practical manner, and it has good potential for use as a perfusion imaging agent in lung scans

  6. Use of hypoxia imaging agent 99mTc-HL91 in rat cerebral ischemia models

    Zhou Ying; Qu Wanying; Li Meng; Chen Fang; Yao Zhiming; Zhu Ming; Zhu Lin

    1999-01-01

    Objective: To explore the possibility of diagnosis for cerebrovascular disease by a novel synthetic hypoxia agent 99m Tc-HL91 used in rat cerebral ischemia models. Methods: Pharmacological experiments of 99m Tc-HL91 were carried out including common properties, radiochemical purity, stability in vitro, anomalous toxicity test and biodistribution in mice. Fifteen cerebral ischemic rat models were established and received 99m Tc-HL91 scintigraphy. Results: 1) HL91 kits were labelled with 99m Tc easily and showed high radiochemical purity and stability. 2) Rapid clearance in blood, heart and lungs and high activity in liver, kidneys and intestines were observed. Relatively low uptake in brain was identified. 3) The radioactivity in ischemic brain tissue increased significantly at 4h postinjection in both rat images and isolated brain images. 4) The radioactivity ratios of lesion to normal brain tissue by drawing ROIs in isolated brain planar images were 0.98 +- 0.06, 0.99 +- 0.05, 1.29 +- 0.03, 1.56 +- 0.14 and 1.66 +- 0.06 at 1,2,4,8 and 12 h postinjection, respectively. There were significant differences among all groups except for 1 h and 2 h, 8 h and 12 h postinjection (P 99m Tc-HL91 in the hypoxic, ischemic brain tissue have been proved. It is appropriate to perform imaging at 4 h postinjection

  7. Preclinical Assessment of a 68Ga-DOTA-Functionalized Depsipeptide as a Radiodiagnostic Infection Imaging Agent.

    Ebenhan, Thomas; Mokaleng, Botshelo Brenda; Venter, Jacobus Daniel; Kruger, Hendrik Gert; Zeevaart, Jan Rijn; Sathekge, Mike

    2017-08-24

    The study assessed a radiolabeled depsipeptide conjugate ( 68 Ga-DOTA-TBIA101) for its potential as an imaging agent targeting infection or infection-associated inflammation. 68 Ga-labeled DOTA-TBIA101 imaging was performed in (NZR1) healthy rabbits; (NZR2) rabbits bearing muscular sterile inflammation and Staphylococcus aureus (SA) infection; and (NZR3) rabbits infected with Mycobacterium tuberculosis (MTB) combined with a subcutaneous scruff infection of SA in the same animal. All animals were imaged using a PET/CT scanner at 5 and 60 min post injection. Images showed elevated accumulation of 68 Ga-DOTA-TBIA101 in the sterile muscular inflammation site (T/NT ratio = 2.6 ± 0.37 (5 min) and 2.8 ± 2.3 (60 min)) and muscles infected with MTB (T/NT ratio = 2.6 ± 0.35 (5 min) and 2.8 ± 0.16 (60 min)). The findings suggest that 68 Ga-DOTA-TBIA101-PET/CT may detect MTB-associated inflammation, although more foundational studies need to be performed to rationalize the diagnostic value of this technique.

  8. sup(99m)Tc-labeled monofluorophosphate as a skeletal imaging agent

    Ichikawa, Tsuneji; Ito, Yasuhiko; Muranaka, Akira; Yokobayashi, Tsuneo; Uchida, Masahiro

    1976-01-01

    The performance of sup(99m)Tc-monofluorophosphate was compared with those of sup(99m)Tc-pyrophosphate and sup(99m)Tc-diphosphonate in rabbits. Studies included chromatographic quality control, measurements of blood clearance, tissue distribution, urinary excretion, skeletal imaging, and measurements of the serum calcium. The labeling for sup(99m)Tc-monofluorophosphate was 98% on paper chromatography and 85% on thin layer chromatography. A large fraction of the activity of the three labeled agents was cleared very rapidly from the bloodstream: however, slow components of the curves were the highest for sup(99m)Tc-monofluorophosphate and lowest for sup(99m)Tc-diphosphonate. Three hours after injection 20% of the dose of sup(99m)Tc-monofluorophosphate was taken up by bone. The corresponding values of sup(99m)Tc-pyrophosphate and sup(99m)Tc-diphosphonate were 29.1% and 40.0% respectively. Ratio of concentration in bone to that in other major organs was highest with sup(99m)Tc-diphosphonate. Ratios were similar for both sup(99m)Tc-monofluorophosphate and sup(99m)Tc-pyrophosphate and much lower than those of sup(99m)Tc-diphosphonate. No significant differences were demonstrated in urinary excretion of the three labeled agents. Visual comparison of the scans obtained with three compounds confirmed the results of radioassay. All were excellent skeletal imaging agents, although sup(99m)Tc-diphosphonate appeared to be superior to the other two mainly because of a higher target to non-target ratio. With 50 mg of monofluorophosphate and 1 mg of stannous fluoride, no hypocalcemia was observed. (J.P.N.)

  9. Study on folate receptor PET imaging agent 18F-flurophenethyl folate

    Guo Congying; Zhu Jianhua; Qian Jun; Yang Yang; Shen Haixing; Zhang Zhengwei

    2009-01-01

    This work is aimed at synthesizing an 18 F-labelled folate derivative that can be used as folate-receptor induced tumor PET imaging agent. Under the optimal reaction and testing specification formulated during the cold-labeling experiments, 18 F labeling of folic acid was achieved in three steps of 18 F pre-labeling,bromination and esterification. The receptor binding property of the newly-synthesized folate radio-derivative was studied through β-lactoglobulin binding test. Tumor-bearing nude mice injected with the new compound were used to study whether the derivative can accumulate within tumor issue. Preliminary studies in vitro and in vivo showed that this new PET agent still possessed receptor binding qualities of folic acid. 18 F-flurophenethyl folate remained good affinity and specificity with β-lactoglobulin. Accumulation of activities in tumor tissues was found in tumor-bearing nude mice. A new folate receptor ligand: 18 F-flurophenethyl folate was synthesized,with high yield and good stability. Since the pre-labeling method was used, the fluorine labeling was not directly imposed upon folic acid.In this way, the structure destruction, which happens in high temperature reaction of folic acid, can be avoided. The synthesized folate derivative remained the binding structural quality of folic acid and could bind with the folate-binding protein: β-lactoglobulin. Through the folate receptors located on tumor tissues, 18 F-flurophenethyl folate accumulated in the tumor tissue, exhibiting its potential as a tumor PET imaging agent. (authors)

  10. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis.

    Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R

    2017-09-01

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (Pappendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.

  11. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    Ogunlade, Olumide; Beard, Paul

    2015-01-01

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  12. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    Ogunlade, Olumide, E-mail: o.ogunlade@ucl.ac.uk; Beard, Paul [Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT (United Kingdom)

    2015-01-15

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  13. An agent harms a victim: A functional magnetic resonance imaging study on specific moral emotions

    Kedia, G. [INSERM, Inst Hlth et Med Res, U797, Res Unit Neuroimaging Psychiat, F-91401 Orsay (France); Kedia, G.; Martinot, J.L. [CEA, DSV, I2BM, SHFJ, Orsay (France); Kedia, G.; Martinot, J.L. [Univ Paris Sud, U797, Paris (France); Kedia, G.; Hilton, D. [Univ Toulouse, Toulouse (France); Berthoz, S. [Paris Descartes Univ, U797, Paris (France); Wessa, M. [Univ Heidelber, Cent Inst Mental Hlth, D-6800 Mannheim (Germany)

    2008-07-01

    The statement 'An agent harms a victim' depicts a situation that triggers moral emotions. Depending on whether the agent and the victim are the self or someone else, it can lead to four different moral emotions: self-anger ('I harm myself'), guilt ('I harm someone'), other-anger ('someone harms me'), and compassion ('someone harms someone'). In order to investigate the neural correlates of these emotions, we examined brain activation patterns elicited by variations in the agent (self vs. other) and the victim (self vs. other) of a harmful action. Twenty-nine healthy participants underwent functional magnetic resonance imaging while imagining being in situations in which they or someone else harmed themselves or someone else. Results indicated that the three emotional conditions associated with the involvement of other, either as agent or victim (guilt, other-anger, and compassion conditions), all activated structures that have been previously associated with the Theory of Mind (ToM, the attribution of mental states to others), namely, the dorsal medial prefrontal cortex, the precuneus, and the bilateral temporo-parietal junction. Moreover, the two conditions in which both the self and other were concerned by the harmful action (guilt and other-anger conditions) recruited emotional structures (i. e., the bilateral amygdala, anterior cingulate, and basal ganglia). These results suggest that specific moral emotions induce different neural activity depending on the extent to which they involve the self and other. (authors)

  14. Preclinical pharmacological studies of 99Tcm-TRODAT-1 as a dopamine transporter imaging agent

    Fang Ping; Wan Weixing; Liu Zhenguo; Wu Chunying; Chen Shengdi; Chen Zhengping; Zhou Xiang; Ji Shuren

    2001-01-01

    Objective: To develop a 99 Tc m labelled dopamine transporter (DAT) imaging agent, 99 Tc m -TRODAT-1 [TRODAT-1: 2β-([N,N'-bis(2-mercaptoethyl) ethylene diamino] methyl), 3β-(4-chlorophenyl) tropane], for evaluating the variation of DAT in patients with Parkinson's disease. Methods: 99 Tc m -TRODAT-1 was successfully prepared on a kit basis. Preclinical pharmacological studies were performed in rats, mice, rabbits, monkeys and a volunteer with diagnosed Parkinson disease (PD). Results: Radiochemical purity of 99 Tc m -TRODAT-1 was over 90%, and remained stable for 6 hours. The specific uptake in striatum was significantly diminished, from 3.45 to 0.12 at 2 h by pretreating rats with a dose of DAT competing ligand, β-CIT [1 mg/kg, 2β-carbomethoxy-3β-(4-iodophenyl) tropane]. Blood clearance kinetics was studied in rabbits, and the initial half-life was of 1.2 min, the elimination half-life was of 368 min. Images of normal monkey's brain exhibited an excellent accumulation in basal ganglia region, where dopamine neurons were concentrated. In hemi parkinsonism model monkeys, the ratio of normal ST/CB and lesioned ST/CB were 1.56 and 0.94, respectively. Brain imaging studies in volunteer indicated that uptake and retention in the basal ganglia, the ratio of normal striatal uptake to lesioned one's was 1.15 measured by SPECT imaging at 2 h. The result of imaging was conformable with his clinical symptoms. Conclusions: The stable, neutral and lipophilic complex, 99 Tc m -TRODAT-1, can be accumulated in the striatal area, where DAT is concentrated, high quality images can be obtained. It suggests that 99 Tc m -TRODAT-1 might be a safe and effective tracer for monitoring the variation in DAT which is associated with various neurodegenerative diseases

  15. A tri-modal molecular imaging agent for sentinel lymph node mapping

    Qin, Zhengtao; Hoh, Carl K.; Hall, David J.; Vera, David R.

    2015-01-01

    Introduction: We report an “instant kit” method to radiolabel fluorescent-tilmanocept with 68 Ga and 99m Tc for tri-modal molecular imaging of sentinel lymph nodes (SLNs). Methods: Solutions of sodium acetate, 68 GaCl 3 and Na 99m TcO 4 were added successively to a “kit vial” containing lyophilized 800CW-tilmanocept, SnCl 2 , trehalose and ascorbic acid. After a 30-min incubation, the pH was neutralized with PBS. No purification was required. Radiochemical and fluorescence purity was measured by HPLC and ITLC techniques. In vitro stability was measured by standing gel chromatography (SGC) and ITLC by a 100-fold dilution 0.25 h after radiolabeling. In vivo stability was measured by SGC and ITLC after an 11 h incubation in human plasma. A dose (0.1 nmol, ~ 1 MBq 68 Ga, ~ 25 MBq 99m Tc) was injected to the footpad of 4 mice. Popliteal SLNs were imaged by PET and fluorescence imaging systems at 0.5, 24, 48, 72 h, then excised and assayed for 99m Tc. Results: Radiochemical and fluorescent purity exceeded 98%. The in vitro stability assay demonstrated high irreversibility of both radiolabels and the fluorescent label, and in vivo stability assay demonstrated high stability of the technetium and fluorescent labels to plasma metabolism. Popliteal SLNs were identified by PET and fluorescence imaging within 0.5 h of injection. SLN fluorescence intensity remained constant for 72 h, when ~ 1% of the injected dose resided in the SLN. Conclusions: Fluorescent-labeled tilmanocept can be radiolabeled with 68 Ga and 99m Tc by the sequential addition of each generator eluate to a lyophilized kit. The resulting tri-modal agent provides: PET images for pre-operative SLN mapping, fluorescence imaging up to 72 hours after injection, and quantitative radiometric measurement of SLN accumulation after excision.

  16. Pharmacological experiment of 13N-ammonia as PET imaging agent

    Wang Mingfang; Tang Ganghua; Gao Xiao; Li Zhi; Wu Hubing; Huang Zuhan; Jiang Hong; Zhong Jinmei; Wang Quanshi

    2002-01-01

    . 13 N-ammonia is an ideal myocardial blood flow perfusion imaging agent. rMBF can be measured accurately and noninvasively by 13 N-ammonia dynamic and static PET imaging

  17. Antibiofouling polymer coated gold nanoparticles as a dual modal contrast agent for X-ray and photoacoustic imaging

    Guojia Huang; Yi Yuan; Xing Da

    2011-01-01

    X-ray is one of the most useful diagnostic tools in hospitals in terms of frequency of use and cost, while photoacoustic (PA) imaging is a rapidly emerging non-invasive imaging technology that integrates the merits of high optical contrast with high ultrasound resolution. In this study, for the first time, we used gold nanoparticles (GNPs) as a dual modal contrast agent for X-ray and PA imaging. Soft gelatin phantoms with embedded tumor simulators of GNPs in various concentrations are clearly shown in both X-ray and PA imaging. With GNPs as a dual modal contrast agent, X-ray can fast detect the position of tumor and provide morphological information, whereas PA imaging has important potential applications in the image guided therapy of superficial tumors such as breast cancer, melanoma and Merkel cell carcinoma.

  18. Synthesis and in vivo magnetic resonance imaging evaluation of biocompatible branched copolymer nanocontrast agents

    Jackson AW

    2015-09-01

    Full Text Available Alexander W Jackson,1,* Prashant Chandrasekharan,2,* Jian Shi,3 Steven P Rannard,4 Quan Liu,5 Chang-Tong Yang,6 Tao He1,7 1Institute of Chemical and Engineering Sciences (ICES, 2Laboratory of Molecular Imaging, Singapore Bioimaging Consortium, Agency for Science Technology and Research (A* STAR, 3Department of Biological Science, National University of Singapore, Singapore; 4Department of Chemistry, University of Liverpool, Liverpool, United Kingdom; 5School of Chemical and Biomedical Engineering, 6Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore; 7School of Chemistry and Chemical Engineering, HeFei University of Technology, Anhui, People’s Republic of China *These authors contributed equally to this work Abstract: Branched copolymer nanoparticles (Dh =20–35 nm possessing 1,4,7, 10-tetraazacyclododecane-N,N',N",N'"-tetraacetic acid macrocycles within their cores have been synthesized and applied as magnetic resonance imaging (MRI nanosized contrast agents in vivo. These nanoparticles have been generated from novel functional monomers via reversible addition–fragmentation chain transfer polymerization. The process is very robust and synthetically straightforward. Chelation with gadolinium and preliminary in vivo experiments have demonstrated promising characteristics as MRI contrast agents with prolonged blood retention time, good biocompatibility, and an intravascular distribution. The ability of these nanoparticles to perfuse and passively target tumor cells through the enhanced permeability and retention effect is also demonstrated. These novel highly functional nanoparticle platforms have succinimidyl ester-activated benzoate functionalities within their corona, which make them suitable for future peptide conjugation and subsequent active cell-targeted MRI or the conjugation of fluorophores for bimodal imaging. We have also demonstrated that these branched copolymer nanoparticles are able to noncovalently

  19. 99mTc-Alafosfalin: an antibiotic peptide infection imaging agent

    Tsopelas, C.; Penglis, S.; Ruszkiewicz, A.; Bartholomeusz, F.D.L.

    2003-01-01

    The radiolabeled antibiotic peptide 99m Tc-alafosfalin was assessed as an infection imaging agent in a rat model by comparison with 99m Tc-DTPA and 99m Tc-leukocytes. 99m Tc-alafosfalin was prepared via an instant cold kit and 99m Tc-leukocytes were prepared using 99m Tc-stannous fluoride colloid in an ex vivo labeling procedure of whole blood. In separate experiments, the three radiotracers were administered to rats infected with staphylococcus aureus. Quantitative biodistribution studies were performed as well as scintigraphic images and histopathology. 99m Tc-alafosfalin is a stable product, obtained in high radiochemical purity (>95%). This agent was mainly renally excreted, with low liver, spleen and bone uptake, and resulted in a mean ratio of infected/non-infected thighs of 4.3/1.0 at 4 hr post radiotracer injection. 99m Tc-DTPA gave a corresponding ratio of 1.9/1.0 and 99m Tc-leukocytes gave 20.0/1.0 at the same time point. An in vitro assay found the level of 99m Tc-alafosfalin binding to staphylococcus aureas higher than 99m Tc-DTPA (10% versus 1% respectively). 99m Tc-alafosfalin accumulates at sites of infection in a rat model better than the perfusion molecule 99m Tc-DTPA, yet less than 99m Tc-leukocytes. The distribution characteristics of this 99m Tc-antibiotic peptide would be an advantage in imaging abdominal and soft tissue infection

  20. Metal-oxo containing polymer nanobeads as potential contrast agents for magnetic resonance imaging

    Pablico, Michele Huelar

    Magnetic resonance imaging (MRI) has greatly revolutionized the way diseases are detected and treated, as it is a non-invasive imaging modality solely based on the interaction of radiowaves and hydrogen nuclei in the presence of an external magnetic field. It is widely used today for the diagnosis of diseases as it offers an efficient method of mapping structure and function of soft tissues in the body. Most MRI examinations utilize paramagnetic materials known as contrast agents, which enhance the MR signal by decreasing the longitudinal (T1) and transverse (T2) relaxation times of the surrounding water protons in biological systems. This results into increased signal intensity differences thereby allowing better interpretation and analysis of pathological tissues. Contrast agents function by lowering the T1 or lowering the T2, resulting into bright and dark contrasts, respectively. The most common MRI contrast agents that are in clinical use today are gadolinium chelates and superparamagnetic iron oxide nanoparticles, both of which have their own advantages in terms of contrast enhancement properties. In the past few years, however, there has been interest in utilizing metal-containing clusters for MRI contrast enhancement as these materials bridge the gap between the constrained structure and magnetic properties of the gadolinium chelates with the superparamagnetic behavior of the iron oxide nanoparticles. Recently, metallic clusters containing Mn and Fe metal centers have received increased attention mainly because of their potential for high spin states and benign nature. In the quest to further develop novel imaging agents, this research has focused on investigating the use of metal-oxo clusters as potential contrast agents for MRI. The primary goal of this project is to identify clusters that meet the following criteria: high paramagnetic susceptibility, water-soluble, stable, cheap, contain environmentally benign metals, and easily derivatized. This work is

  1. A Review of Circulating Tumor DNA in Hepatobiliary Malignancies

    Kabir Mody

    2018-06-01

    Full Text Available Circulating tumor DNA (ctDNA is released into circulation (blood specifically from tumor cells undergoing metabolic secretion, apoptosis, or necrosis, carries tumor-specific genetic or epigenetic alterations. Technologies enabling clinical evaluation of ctDNA continue to advance rapidly and allow for the assessment of patient-specific tumoral genetic and epigenetic alterations. This holds great potential for earlier detection of disease, serial monitoring of tumor heterogeneity, identification of therapeutic targets, and evaluation of treatment response and mechanisms of resistance. Hepatobiliary malignancies are often diagnosed late, recur commonly, yield limited available tumor on biopsy, and harbor several genomic alterations with potential therapeutic impacts. Patients suffering from or at risk for these diseases thus stand to benefit immensely from this technology. Herein, we review the limited literature pertaining to the potential for ctDNA technologies in such patients. Patients with these cancers stand to benefit greatly from the application of ctDNA technologies, and concerted efforts at further investigation of such are ongoing and greatly needed.

  2. Diagnostic value of β amyloid plaques imaging agent 131I-IMPY brain imaging in early Alzheimer's disease

    Ye Wanzhong; Lu Chunxiong; Yang Min; Bao Jiandong; Cheng Zhaohuo; Cai Deliang; Wang Zhiqiang; Yang Bixiu

    2012-01-01

    Objective: To evaluate the diagnostic value of β-amyloid plaques imaging agent [ 131 I] 2( 4-dimethylaminop henyl)-6-iodoimidazo [1, 2-α] pyridine ( 131 I-IMPY) SPECT imaging in early Alzheimer's Disease. Methods: 24 cases of AD (7 males, 17 females, aged 48∼79 years) and 14 normal (6 males, 8 females, aged 42∼67 years) control subjects were selected for this study. 131 I-IMPY SPECT imaging was carried out 2-3 h post injection. 131 I-IMPY uptake defined as the ratio of each brain gyrus and cerebellum uptake on fixed region of interest (ROI) (Rcl/cb) was calculated. Comparative analysis between the two groups was carried out using t-test. Results: In patients with early AD (MCI), 131 I-IMPY was increased in parietal gyrus, temporal gyrus and frontal gyrus compared with normal control group and it were found to be statistically significant (t = 1.3967∼2.8757, all P 0.05). In patients with AD, increase in 131 I-IMPY were observed in parietal, temporal, occipital lobes and basal ganglia compared with normal control group and it were found to be statistically significant (t=2.1001∼6.2789, all P 0.05), and 131 I-IMPY was increased in occipital lobes and basal ganglia compared with MCI group and it were found to be statistically significant (t=2.0850∼3.6772, all P 131 I-IMPY was lightly increased in each brain of left side gyrus compared with right but without statistically significant difference (t=0.1273∼0.5571, all P>0.05). Conclusions: 131 I-IMPY SPECT Imaging was helpful for early diagnosis of AD. (authors)

  3. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    Ahmad, Tanveer [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Department of Physics, Abdul Wali Khan University, Mardan (Pakistan); Bae, Hongsub; Iqbal, Yousaf [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Rhee, Ilsu, E-mail: ilrhee@knu.ac.kr [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Hong, Sungwook [Division of Science Education, Daegu University, Gyeongsan 712-714 (Korea, Republic of); Chang, Yongmin; Lee, Jaejun [Department of Diagnostic Radiology, College of Medicine, Kyungpook National University and Hospital, Daegu 700-721 (Korea, Republic of); Sohn, Derac [Department of Physics, Hannam University, Daejon (Korea, Republic of)

    2015-05-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe{sub 2}O{sub 4}) nanoparticles as both T{sub 1} and T{sub 2} contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T{sub 1} and T{sub 2} relaxivities were 0.858±0.04 and 1.71±0.03 mM{sup −1} s{sup −1}, respectively. In animal experimentation, both a 25% signal enhancement in the T{sub 1}-weighted mage and a 71% signal loss in the T{sub 2}-weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T{sub 1} and T{sub 2} contrast agents in MRI. We note that the applicability of our nanoparticles as both T{sub 1} and T{sub 2} contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles. - Highlights: • Chitosan-coated nickel-ferrite (Ni-Fe{sub 2}O{sub 4}) nanoparticles were synthesized in an aqueous system by chemical co-precipitation. • The characterization of bare and chitosan-coated nanoparticles were performed using various analytical tools, such as TEM, FTIR, XRD, and VMS. • We evaluated the coated particles as potential T{sub 1} and T{sub 2} contrast agents for MRI by measuring T{sub 1} and T{sub 2} relaxation times as a function of iron concentration. • Both T{sub 1} and T{sub 2} effects were also observed in animal experimentation.

  4. Biocompatible KMnF3 nanoparticular contrast agent with proper plasma retention time for in vivo magnetic resonance imaging.

    Liu, Zhi-jun; Song, Xiao-xia; Xu, Xian-zhu; Tang, Qun

    2014-04-18

    Nanoparticular MRI contrast agents are rapidly becoming suitable for use in clinical diagnosis. An ideal nanoparticular contrast agent should be endowed with high relaxivity, biocompatibility, proper plasma retention time, and tissue-specific or tumor-targeting imaging. Herein we introduce PEGylated KMnF3 nanoparticles as a new type of T1 contrast agent. Studies showed that the nanoparticular contrast agent revealed high bio-stability with bovine serum albumin in PBS buffer solution, and presented excellent biocompatibility (low cytotoxicity, undetectable hemolysis and hemagglutination). Meanwhile the new contrast agent possessed proper plasma retention time (circulation half-life t1/2 is approximately 2 h) in the body of the administrated mice. It can be delivered into brain vessels and maintained there for hours, and is mostly cleared from the body within 48 h, as demonstrated by time-resolved MRI and Mn-biodistribution analysis. Those distinguishing features make it suitable to obtain contrast-enhanced brain magnetic resonance angiography. Moreover, through the process of passive targeting delivery, the T1 contrast agent clearly illuminates a brain tumor (glioma) with high contrast image and defined shape. This study demonstrates that PEGylated KMnF3 nanoparticles represent a promising biocompatible vascular contrast agent for magnetic resonance angiography and can potentially be further developed into an active targeted tumor MRI contrast agent.

  5. Radiolabelling and evaluation of a novel sulfoxide as a PET imaging agent for tumor hypoxia

    Laurens, Evelyn; Yeoh, Shinn Dee; Rigopoulos, Angela; Cao, Diana; Cartwright, Glenn A.; O'Keefe, Graeme J.; Tochon-Danguy, Henri J.; White, Jonathan M.; Scott, Andrew M.; Ackermann, Uwe

    2014-01-01

    [ 18 F]FMISO is the most widely validated PET radiotracer for imaging hypoxic tissue. However, as a result of the pharmacokinetics of [ 18 F]FMISO a 2 h wait between tracer administration and patient scanning is required for optimal image acquisition. In order to develop hypoxia imaging agents with faster kinetics, we have synthesised and evaluated several F-18 labelled anilino sulfoxides. In this manuscript we report on the synthesis, in vitro and in vivo evaluation of a novel fluoroethyltriazolyl propargyl anilino sulfoxide. The radiolabelling of the novel tracer was achieved via 2-[ 18 F]fluoroethyl azide click chemistry. Radiochemical yields were 23 ± 4% based on 2-[ 18 F]fluoroethyl azide and 7 ± 2% based on K[ 18 F]F. The radiotracer did not undergo metabolism or defluorination in an in vitro assay using S9 liver fractions. Imaging studies using SK-RC-52 tumors in BALB/c nude mice have indicated that the tracer may have a higher pO 2 threshold than [ 18 F]FMISO for uptake in hypoxic tumors. Although clearance from muscle was faster than [ 18 F]FMISO, uptake in hypoxic tumors was slower. The average tumor to muscle ratio at 2 h post injection in large, hypoxic tumors with a volume greater than 686 mm 3 was 1.7, which was similar to the observed ratio of 1.75 for [ 18 F]FMISO. Although the new tracer showed improved pharmacokinetics when compared with the previously synthesised sulfoxides, further modifications to the chemical structure need to be made in order to offer significant in vivo imaging advantages over [ 18 F]FMISO

  6. Advances in technetium chemistry towards 99mTc receptor imaging agents

    Johannsen, B.; Spies, H.

    1997-01-01

    The development of the chemistry of technetium and its non-radioactive surrogate rhenium has been prompted by the trends and needs of nuclear medicine, which predominantly uses 99m Tc radiopharmaceuticals for a broad range of diagnostics. Technetium-99m is the ideal radioisotope for tomographic single-photon emission tomography (SPECT) imaging due to its nuclear properties (6.2 h, E γ 140 keV) and ready availability through generator systems. Transition metals offer many opportunities for designing molecules by modifying the environment around the core, allowing certain biological properties to be imposed upon the molecule. Whereas research in the past was mainly concerned with biological properties that allow relatively unspecific functional imaging, as in brain or myocardium perfusion studies, nuclear medicine is now requiring more and more biochemical information on low capacity, high specificity targets. Many research groups have become involved in the search for new technetium-based compounds, called the third generation of 99m Tc radiopharmaceuticals, that employ the principles of modern pharmacology to achieve biochemical specificity. There has been considerable interest in imaging CNS and other receptors with 99m Tc receptor-binding ligands. Such a 99m Tc CNS receptor-imaging agent is currently not yet in use because of the significant hurdles to be overcome in attaining this ambitious goal. However, some Tc and Re complexes of remarkable affinity in vitro, and the first high-affinity 99m Tc probes able to label the dopamine transporter in the brain by SPECT imaging prove the feasibility of this approach. (Author)

  7. A pancreas imaging agent-131I-HIPDM: the animal experiment and preliminary clinical application

    Shao Hesheng

    1988-01-01

    131 I-HIPDM has been used clinically for studying regional cerebral perfusion. The [ 131 I] HIPDM was prepared in a kit. The labelling yields were consistently more than 95%, as analyzed by the TLC-Silica gel. The labelled compound is stable in vitro and in vivo. S D Strain rats (170-220 g) and mice (18-22 g) were used. The pancreatic uptake of [ 131 I] HIPDM is rather slow in mice and rats. At 8 hr after iv, the pancreas activity and the pancreas to liver (P/L) ratio are highest in mice and rats. The effect of carrier loading dose from 0.010 to 6.0 mg/kg on blodistribution in mice has been studied. The liver uptake was increased by adding carrier HIPDM. The result indicates that administration between 0.010 and 0.05 mg/kg carrier dose is most suitable for the pancreas imaging. Gamma camera imaging of dog at 6 hr after iv with 300 μCi [ 131 I] HIPMD, 0.05 mg/kg body weight showed clear pancreas image. The P/L ratio of the dog is 0.40. Preliminary clinical tests were satisfactory. Using 1 to 1.5 mCi of [ 131 I] HIPDM, 0.05 mg/kg, the pancreas imaging was operated in 4 cases of volunteers and pancreas cyst respectively with the good diagnostic quality. The authors are of the opinion that this pancreas imaging agent may have potential value for routine use

  8. Short-lived cyclotron produced radionuclides evaluation on the myocardial imaging agents

    Rikitake, Tomoyuki; Tateno, Yukio; Yamane, Akiko; Matsumoto, Touru; Umegaki, Youichiro

    1978-01-01

    Organ uptake after venous administration of 13 N-ammonia, 43 K, 86 Rb, 201 Tl and after rectal administration of 13 N-ammonia was studied. Each nuclides highly accumulated in myocardium after intravenous injection, but rectal administrated 13 N-ammonia did not show this tendency. Intravenously injected 13 N-ammonia showed very early myocardial uptake and early secretion from kidney. Rectal administrated 13 N-ammonia was less accumulated in myocardium. 43 KCl and 13 NH 4 Cl were injected intravenously and administrated from the rectum to the rabbits under imaging scintilator system. Whole-body scintiscanner with display-processing unit was used for a 43 KCl injected rabbit. A positroncamera with computer system (TOSBAC 3400 on line system) was used for 13 NH 4 Cl (i.v. and rectal ad.) rabbits. The dynamic studies of 43 KCl, 13 NH 4 Cl were made from these imaging data. The countratio of heart to the liver after 43 K injection was nearly equal or less than the liver. The peakcount was at 15 min after 13 NH 4 Cl intravenous injection. 13 N accumulated promptly at upper mediastinal part and kidney, and soon disappeared from these part. Uptake of the heat was high and that of the liver was low. When 13 NH 4 Cl was administrated from the rectum, 13 N trapped at the liver, and uptake of the heart was very low level. Scintiscanning after 13 KCl intravenously injected, did not show the high resolution. Rabbit heart was distinguishable from the liver, but there are no visibility of the detail. Seeing positronscintigram after 13 NH 4 Cl administration both from intravenously and from rectum, the detail was well visible. We concluded the positron scintigram after 13 NH 4 Cl injection should be a good myocardial imaging agent. Furthermore, 13 Nh 4 Cl has two eminent characters as a myocardial imaging agent comparing 201 TlCl. One is prompt making of image, the others is the very low radiation dose. (auth.)

  9. Residualization Rates of Near-Infrared Dyes for the Rational Design of Molecular Imaging Agents.

    Cilliers, Cornelius; Liao, Jianshan; Atangcho, Lydia; Thurber, Greg M

    2015-12-01

    Near-infrared (NIR) fluorescence imaging is widely used for tracking antibodies and biomolecules in vivo. Clinical and preclinical applications include intraoperative imaging, tracking therapeutics, and fluorescent labeling as a surrogate for subsequent radiolabeling. Despite their extensive use, one of the fundamental properties of NIR dyes, the residualization rate within cells following internalization, has not been systematically studied. This rate is required for the rational design of probes and proper interpretation of in vivo results. In this brief report, we measure the cellular residualization rate of eight commonly used dyes encompassing three core structures (cyanine, boron-dipyrromethene (BODIPY), and oxazine/thiazine/carbopyronin). We identify residualizing (half-life >24 h) and non-residualizing (half-life <24 h) dyes in both the far-red (~650-680 nm) and near-infrared (~740-800 nm) regions. This data will allow researchers to independently and rationally select the wavelength and residualizing nature of dyes for molecular imaging agent design.

  10. Image Cytometric Analysis of Algal Spores for Evaluation of Antifouling Activities of Biocidal Agents.

    Il Koo, Bon; Lee, Yun-Soo; Seo, Mintae; Seok Choi, Hyung; Leng Seah, Geok; Nam, Taegu; Nam, Yoon Sung

    2017-07-31

    Chemical biocides have been widely used as marine antifouling agents, but their environmental toxicity impose regulatory restriction on their use. Although various surrogate antifouling biocides have been introduced, their comparative effectiveness has not been well investigated partly due to the difficulty of quantitative evaluation of their antifouling activity. Here we report an image cytometric method to quantitatively analyze the antifouling activities of seven commercial biocides using Ulva prolifera as a target organism, which is known to be a dominant marine species causing soft fouling. The number of spores settled on a substrate is determined through image analysis using the intrinsic fluorescence of chlorophylls in the spores. Pre-determined sets of size and shape of spores allow for the precise determination of the number of settled spores. The effects of biocide concentration and combination of different biocides on the spore settlement are examined. No significant morphological changes of Ulva spores are observed, but the amount of adhesive pad materials is appreciably decreased in the presence of biocides. It is revealed that the growth rate of Ulva is not directly correlated with the antifouling activities against the settlement of Ulva spores. This work suggests that image cytometric analysis is a very convenient, fast-processable method to directly analyze the antifouling effects of biocides and coating materials.

  11. Contrast agent based on nano-emulsion for targeted biomedical imaging

    Attia, Mohamed

    2016-01-01

    X-ray imaging agents are essential in combination with X-ray computed tomography to improve contrast enhancement aiming at providing complete visualization of blood vessels and giving structural and functional information on lesions allowing the detection of a tumor. As well as it is fundamental tool to discriminate between healthy cells and pathogens. We successfully limit the problems presented in commercial X-ray contrast agents like poor contrasting in Fenestra VC associated with short blood circulation time and to avoid rapid renal elimination from the body as found in Xenetix (Iobitriol). We developed nontoxic and blood pool iodine-containing nano-emulsion contrast agents serving in preclinical X-ray μ-CT imaging such as, a- Tocopherol (vitamin E), Cholecalciferol (vitamin D3), Castor oil, Capmul MCMC8 oil and oleic acid. Those formulated nano emulsions were prepared by low energy spontaneous emulsification technic with slight modification for each platform. They showed new specific features rendering them promising agents in in vivo experiments as improving the balance between the efficacy and the toxicity of targeted therapeutic interventions. We investigate the effect of size and the chemical composition of the nanoparticles on their biodistribution, pharmacokinetics and toxicity. They demonstrated that the chemical structures of the droplet's cores have significant role in targeting for example vitamin E was mainly accumulated in liver and castor oil formulation was passively accumulated in spleen explaining the proof-of-concept of EPR effect. On the other hand, two different platform sizes of Cholecalciferol molecule revealing that no real impact on the pharmacokinetics and biodistribution but presented remarkable effect on the toxicity. Of particular interest is studying the effect of the surface charge of nanoparticles on their biodistribution, this is why oleic acid nano-emulsion was selected to proceed this study by presence of amphiphilic polymer

  12. A Proposed Computed Tomography Contrast Agent Using Carboxybetaine Zwitterionic Tantalum Oxide Nanoparticles: Imaging, Biological, and Physicochemical Performance.

    FitzGerald, Paul F; Butts, Matthew D; Roberts, Jeannette C; Colborn, Robert E; Torres, Andrew S; Lee, Brian D; Yeh, Benjamin M; Bonitatibus, Peter J

    2016-12-01

    The aim of this study was to produce and evaluate a proposed computed tomography (CT) contrast agent based on carboxybetaine zwitterionic (CZ)-coated soluble tantalum oxide (TaO) nanoparticles (NPs). We chose tantalum to provide superior imaging performance compared with current iodine-based clinical CT contrast agents. We developed the CZ coating to provide biological and physical performance similar to that of current iodinated contrast agents. In addition, the aim of this study was to evaluate the imaging, biological, and physicochemical performance of this proposed contrast agent compared with clinically used iodinated agents. We evaluated CT imaging performance of our CZ-TaO NPs compared with that of an iodinated agent in live rats, imaged centrally located within a tissue-equivalent plastic phantom that simulated a large patient. To evaluate vascular contrast enhancement, we scanned the rats' great vessels at high temporal resolution during and after contrast agent injection. We performed several in vivo CZ-TaO NP studies in healthy rats to evaluate tolerability. These studies included injecting the agent at the anticipated clinical dose (ACD) and at 3 times and 6 times the ACD, followed by longitudinal hematology to assess impact to blood cells and organ function (from 4 hours to 1 week). Kidney histological analysis was performed 48 hours after injection at 3 times the ACD. We measured the elimination half-life of CZ-TaO NPs from blood, and we monitored acute kidney injury biomarkers with a kidney injury assay using urine collected from 4 hours to 1 week. We measured tantalum retention in individual organs and in the whole carcass 48 hours after injection at ACD. Carboxybetaine zwitterionic TaO NPs were synthesized and analyzed in detail. We used multidimensional nuclear magnetic resonance to determine surface functionality of the NPs. We measured NP size and solution properties (osmolality and viscosity) of the agent over a range of tantalum concentrations

  13. Preparation of 99mTc-Ancitabine as a Possible Tumor Imaging Agent

    Ibrahim, I.T.; Attallah, K.M.

    2010-01-01

    Ancitabine is one of the potent chemotherapeutic anticancer drugs. Tc-Ancitabine ( 99m Tc-ANC) was prepared using stannous chloride as reducing agent, which produced yield above 90% at ph 4 at room temperature within 1-5 min as reaction time. The labeled drug was stable for more than 8 h post labeling. Biodistribution study of 99m Tc-ANC in normal mice reflected that its uptake was increased in organ of high proliferation like stomach. In solid tumor bearing mice 99m Tc-ANC was incorporated rapidly in tumor site and declined slowly, while it was declined rapidly from other tissues. Biodistribution of 99m Tc-ANC in solid tumor presented a possible model for imaging of tumors.

  14. Potential new approaches for the development of brain imaging agents for single-photon applications

    Knapp, F.F. Jr.; Srivastava, P.C.

    1984-01-01

    This paper describes new strategies for the brain-specific delivery of radionuclides that can be used to evaluate regional cerebral perfusion by single photon imaging techniques. A description of several examples of interesting new strategies that have recently been reported is presented. A new approach at this institution for the brain-specific delivery of radioiodinated iodophenylalkyl-substituted dihyronicotinamide systems is described which shows good brain uptake and retention in preliminary studies in rats. Following transport into the brain these agents appear to undergo facile intracerebral oxidation to the quaternized analogues which do not recross the intact blood-brain barrier and so are effectively trapped in the brain. 49 refs., 9 figs., 1 tab

  15. Technetium-99m-dimethylglyoxime ([sup 99m]Tc-DMG) as renal imaging agent

    Adonaylo, V.N. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales Buenos Aires Univ. (Argentina). Dept. de Ciencias Biologicas); Stahl, Adriana; Pomilio, A.B.; Vitale, A.A. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales); Canellas, C.O. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales Comision Nacional de Energia Atomica, Buenos Aires (Argentina))

    1993-06-01

    Dimethylglyoxime (DMG) labelled with [sup 99m]Tc is presented as a renal imaging agent. The behaviour of this complex was analysed at different pH by means of UV spectral data and using DMG-calcium chloride as a reference complex. Biokinetic data were evaluated in two biological models, Sprague-Dawley rats and Didelphis albiventris argentine opossum. Biodistribution in rats demonstrated fast and specific renal excretion. Time-activity values over both kidneys could be quantified for this complex. Renographic studies led to mean time-to maximum values on twelve assays of 2.0 [+-] 0.1 min and a mean relative function of 53.0 [+-] 2.3 and 47.0 [+-] 3.2 for right and left kidneys, respectively. [sup 99m]Tc-DMG showed specificity for the renal excretion pathway and therefore seems to be a very useful radiopharmaceutical for renal function studies. (Author).

  16. Radiation dosimetry of iodine-123 HEAT, an alpha-1 receptor imaging agent

    Thomas, K.D.; Greer, D.M.; Couch, M.W.; Williams, C.M.

    1987-01-01

    Biologic distribution data in the rat were obtained for the alpha-1 adrenoceptor imaging agent (+/-) 2-[beta-(iodo-4-hydroxyphenyl)ethylaminomethyl]tetralone (HEAT) labeled with [ 123 I]. The major excretory routes were through the liver (67%) and the kidney (33%). Internal radiation absorbed dose estimates to nine source organs, total body, the GI tract, gonads, and red bone marrow were calculated for the human using the physical decay data for [ 123 I]. The critical organ was found to be the lower large intestine, receiving 1.1 rad per mCi of [ 123 I]HEAT administered. The total-body dose was found to be 58 mrad per mCi

  17. Synthesis and evaluation of p-iodo-phentermine (IP) as a brain perfusion imaging agent

    Kizuka, H.; Elmaleh, D.R.; Brownell, G.L.; Strauss, H.W.

    1985-01-01

    rho-( 123 I and 131 I) iodo α,α-dimethylphenethylamine (rho-iodophentermine, IP) as the α-methylated analogue of iodoamphetamine has been prepared. It is hoped that this methyl substitution will increase the lipophilicity of the agent, enhance resistance to metabolism by monoamine oxidase, and will result in increased initial uptake and slower washout from the brain as compared to N-isopropyl-rho-( 123 I) iodoamphetamine. IP was prepared by diazotization of rho-aminophentermine followed by decomposition of the diazonium salt with KI. Radioiodinated IP was prepared either by the solid-phase isotopic exchange reaction or by decomposition of the piperidinotriazene derivative with a radiochemical yield of 40-60%. Biodistribution of 131 I-IP in rats showed brain uptake in the range of 1.7% dose g -1 at 5, 30 and 60 min. Imaging studies with 123 I-IP in dogs showed high brain extraction and slow washout of activity. (author)

  18. Synthesis and 131I labelling of epidepride as a dopamine D2 receptor imaging agent

    Yang Min; Hu Mingyang; Pei Zhuguo; Wang Bocheng; Zhou Xingqin

    2001-01-01

    S-(-)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-5-iodo-2, 3-dimethoxybenzamide (Epidepride) and its iodine labeling precursor S-(-)-N-[(1-Ethyl-2-pyrrolidinyl)methyl]-5-tributyltin-2, 3-dimethoxybenzamide are synthesized from 3-methoxy salicylic acid. The labeling precursor is labeled with 131 I by hydrogen peroxide method, and 131 I-epidepride is gained, its radiolabelling yield (RLY) and the radiochemical purity (RCP) are all over 95%. The RCP of 131 I-epidepride is over 90% under 4 degree C after 15 days. 131 I-epidepride has high affinity to dopamine D 2 receptor. The striatal uptake can be blocked completely by spiperone. The striatum and cerebellum uptake ratio can reach 237 at 320 min in rats. The results show that 131 I-epidepride may be used as a dopamine D 2 receptor imaging agent for SPECT

  19. On-bead combinatorial synthesis and imaging of chemical exchange saturation transfer magnetic resonance imaging agents to identify factors that influence water exchange.

    Napolitano, Roberta; Soesbe, Todd C; De León-Rodríguez, Luis M; Sherry, A Dean; Udugamasooriya, D Gomika

    2011-08-24

    The sensitivity of magnetic resonance imaging (MRI) contrast agents is highly dependent on the rate of water exchange between the inner sphere of a paramagnetic ion and bulk water. Normally, identifying a paramagnetic complex that has optimal water exchange kinetics is done by synthesizing and testing one compound at a time. We report here a rapid, economical on-bead combinatorial synthesis of a library of imaging agents. Eighty different 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid (DOTA)-tetraamide peptoid derivatives were prepared on beads using a variety of charged, uncharged but polar, hydrophobic, and variably sized primary amines. A single chemical exchange saturation transfer image of the on-bead library easily distinguished those compounds having the most favorable water exchange kinetics. This combinatorial approach will allow rapid screening of libraries of imaging agents to identify the chemical characteristics of a ligand that yield the most sensitive imaging agents. This technique could be automated and readily adapted to other types of MRI or magnetic resonance/positron emission tomography agents as well.

  20. Hepatobiliary scintigraphy and function test with sup(99m)Tc-N-pyridoxyl-5-methyltryptophan (sup(99m)Tc-PMT)

    Sugimura, Kazuro; Nishiyama, Shoji; Narabayashi, Isamu

    1985-01-01

    The authors studied the effectiveness of sup(99m)Tc-N-pyridoxyl-5-methyltryptophan (sup(99m)Tc-PMT) for dynamic imaging and function on 40 patients with various hepatobiliary diseases and on healthy individuals. In healthy subjects, sup(99m)Tc-PMT is rapidly removed from the blood by the parenchymal cells of the liver and is excreted through the biliary system. The imaging of the liver, bile ducts, gallbladder and intestines with sup(99m)Tc-PMT was satisfactory. There was no renal visualization. In the case of serial images of healthy individuals, the gallbladder, intrahepatic bile duct and small intestine were visualized after 18.8 +- 7.2, 8.8 +- 1.4, and 16.7 +- 6.3 min, respectively; the mean peak time on the hepatogram was 8.0 +- 5.3 min. The bile ducts of patients with liver disorders were visualized later than those of healthy individuals. Particularly in the case of severe liver parenchymal diseases, the appearance time for the bile duct was significantly delayed. However, the delays in appearance time did not correlate well with low scores on the liver function test. At 70 min after the intravenous administration of sup(99m)Tc-PMT, 2.5 +- 1.5 % of the injected dose was excreted into the urine of the healthy individuals. The urinary excretion of sup(99m)Tc-PMT by the patients with hepatobiliary diseases showed no increase, and it was not entirely related to the results of the serum function tests. However, a larger amount of sup(99m)Tc-PMT was retained in the blood of the patients with hepatobiliary diseases. The blood retention values at 20 min after injection into those with liver cirrhosis and hepatoma were significantly delayed. (author)

  1. Radioiodination and Biological Evaluation of Atenolol as a Possible Cardiac Imaging Agent

    EI-Mouhty, N.A.R.; Attallah, K.M.; EI-Tawoosy, M.; EI-Kolaly, M.T.

    2008-01-01

    An adopted method for the preparation of high radiochemical purity 125 I iodoatenolol (3-1( 125 I]-4-(2-hydroxy-3-isopropyl aminopropoxy) phenylacetamide) was developed in order to characterize the binding properties ofβ 1 -receptors. Direct radioiodination of atenolol (RS)-4-(2-hydroxy-3-isopropyl aminopropoxy) phenylacetamide) was carried out using chloramine- T (N-chloro-p-toluene sulfonamide sodium salt) or iodogen (1,3,4,6-tetrachloro-3α, 6α-diphenyl glycoril) as an oxidizing agent. The reaction proceeds well within 30 min at ambient room temperature up to 25± 1 degree C and afforded a radiochemical yield up to 85 % as pure as ( 125 I] iodoatenolol increased to over 95 % using neutral lyophilized solution of Na 125 I. Different chromatographic techniques (electrophoresis and thin layer chromatography TLC) were used to evaluate the radiochemical yield and purity of thc labeled product. Biodistribution studies were carried out in normal Albino Swiss mice and the results indicate the possibility of using ( 125 1) iodoatenolol as myocardial imaging agent

  2. Targeting Potassium Channels for Increasing Delivery of Imaging Agents and Therapeutics to Brain Tumors

    Nagendra Sanyasihally Ningaraj

    2013-05-01

    Full Text Available Every year in the US, 20,000 new primary and nearly 200,000 metastatic brain tumor cases are reported. The cerebral microvessels/ capillaries that form the blood–brain barrier (BBB not only protect the brain from toxic agents in the blood but also pose a significant hindrance to the delivery of small and large therapeutic molecules. Different strategies have been employed to circumvent the physiological barrier posed by blood-brain tumor barrier (BTB. Studies in our laboratory have identified significant differences in the expression levels of certain genes and proteins between normal and brain tumor capillary endothelial cells. In this study, we validated the non-invasive and clinically relevant Dynamic Contrast Enhancing-Magnetic Resonance Imaging (DCE-MRI method with invasive, clinically irrelevant but highly accurate Quantitative Autoradiography (QAR method using rat glioma model. We also showed that DCE-MRI metric of tissue vessel perfusion-permeability is sensitive to changes in blood vessel permeability following administration of calcium-activated potassium (BKCa channel activator NS-1619. Our results show that human gliomas and brain tumor endothelial cells that overexpress BKCa channels can be targeted for increased BTB permeability for MRI enhancing agents to brain tumors. We conclude that monitoring the outcome of increased MRI enhancing agents’ delivery to microsatellites and leading tumor edges in glioma patients would lead to beneficial clinical outcome.

  3. EXCI-CEST: Exploiting pharmaceutical excipients as MRI-CEST contrast agents for tumor imaging.

    Longo, Dario Livio; Moustaghfir, Fatima Zzahra; Zerbo, Alexandre; Consolino, Lorena; Anemone, Annasofia; Bracesco, Martina; Aime, Silvio

    2017-06-15

    Chemical Exchange Saturation Transfer (CEST) approach is a novel tool within magnetic resonance imaging (MRI) that allows visualization of molecules possessing exchangeable protons with water. Many molecules, employed as excipients for the formulation of finished drug products, are endowed with hydroxyl, amine or amide protons, thus can be exploitable as MRI-CEST contrast agents. Their high safety profiles allow them to be injected at very high doses. Here we investigated the MRI-CEST properties of several excipients (ascorbic acid, sucrose, N-acetyl-d-glucosamine, meglumine and 2-pyrrolidone) and tested them as tumor-detecting agents in two different murine tumor models (breast and melanoma cancers). All the investigated molecules showed remarkable CEST contrast upon i.v. administration in the range 1-3ppm according to the type of mobile proton groups. A marked increase of CEST contrast was observed in tumor regions up to 30min post injection. The combination of marked tumor contrast enhancement and lack of toxicity make these molecules potential candidates for the diagnosis of tumors within the MRI-CEST approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Quantitative Molecular Imaging with a Single Gd-Based Contrast Agent Reveals Specific Tumor Binding and Retention in Vivo.

    Johansen, Mette L; Gao, Ying; Hutnick, Melanie A; Craig, Sonya E L; Pokorski, Jonathan K; Flask, Chris A; Brady-Kalnay, Susann M

    2017-06-06

    Magnetic resonance imaging (MRI) has become an indispensable tool in the diagnosis and treatment of many diseases, especially cancer. However, the poor sensitivity of MRI relative to other imaging modalities, such as PET, has hindered the development and clinical use of molecular MRI contrast agents that could provide vital diagnostic information by specifically locating a molecular target altered in the disease process. This work describes the specific and sustained in vivo binding and retention of a protein tyrosine phosphatase mu (PTPμ)-targeted, molecular magnetic resonance (MR) contrast agent with a single gadolinium (Gd) chelate using a quantitative MRI T 1 mapping technique in glioma xenografts. Quantitative T 1 mapping is an imaging method used to measure the longitudinal relaxation time, the T 1 relaxation time, of protons in a magnetic field after excitation by a radiofrequency pulse. T 1 relaxation times can in turn be used to calculate the concentration of a gadolinium-containing contrast agent in a region of interest, thereby allowing the retention or clearance of an agent to be quantified. In this context, retention is a measure of molecular contrast agent binding. Using conventional peptide chemistry, a PTPμ-targeted peptide was linked to a chelator that had been conjugated to a lysine residue. Following complexation with Gd, this PTPμ-targeted molecular contrast agent containing a single Gd ion showed significant tumor enhancement and a sustained increase in Gd concentration in both heterotopic and orthotopic tumors using dynamic quantitative MRI. This single Gd-containing PTPμ agent was more effective than our previous version with three Gd ions. Differences between nonspecific and specific agents, due to specific tumor binding, can be determined within the first 30 min after agent administration by examining clearance rates. This more facile chemistry, when combined with quantitative MR techniques, allows for widespread adoption by academic

  5. Radioiodine labelled SP-4 as an imaging agent for atherosclerotic plaques

    Zhang Yongxue; Wu Zhijian; Cao Wei

    2000-01-01

    The clinical prospect of radioiodinated SP-4 as an atherosclerotic plaque imaging agent was studied. The SP-4 was synthesized by a solid phase method and identified by an amino acid analysis after purification with HPLC. SP-4 was labelled with 131 I and 125 I by the Chloramine-T method and purified through Sephadex G-25 column. Twelve New Zealand rabbits were divided into an atherosclerotic group (n = 7, AR) and a control group (n = 5, NR). All of the atherosclerotic rabbits were intravenous administrated with bovine serum albumin, then feb with high cholesterol and fat diet. 125 I-SP-4 was intravenous administrated to the rabbits of both groups. The biodistribution of 125 I-SP-4 in rabbits was investigated. The uptakes (% ID/g) in blood and thoracic aorta and abdominal aorta were calculated 4 hours postinjection. Macro-autoradiography and micro-autoradiography were performed in 2 AR atherosclerotic abdominal aortas. The clearance of radioactivity from plasma was very rapid. 125 I-SP-4 was mainly excreted through kidneys. The radioactive uptakes of abdominal aorta and thoracic aorta of AR at 4 hours postinjection were significantly higher than that of NR. The films of macro-autoradiography showed focal accumulation of the radioactivity in the areas of a newly formed edges of atherosclerotic plaques. On the slices of micro-autoradiography, the obvious radioactive accumulation could be found in the atherosclerotic plaques. Thus it was seen that the SP-4 remained its biological activity after radioiodination and was located at atherosclerotic lesions, it is potentially useful as an atherosclerotic plaque imaging agent

  6. Study of biodistribution properties of a new myocardial imaging agent 99Tcm-N-DBODC5

    Zhang Wanchun; Fang Wei; Wang Feng; Guo Feng; Guo Lin; He Zuoxiang; Wang Xuebin; Lin Bin; Tang Zhigang

    2007-01-01

    99 Tc m -N-DBODC5 for intravenous injection was prepared. The labelling yield was 95.0% ± 0.52%. Sixteen New Zealand rabbits were involved and planar gamma imaging was performed at 10 time-point after injection of 99 Tc m -N-DBODC5. The radioactivity changes of organs were calculated by regions of interest (ROI) analysis. The 16 rabbits were divided into 4 groups and were sacrificed at 30, 60, 120, and 180 min after iniection respectively. The activity for all excised organs were measured by γ-well counting for calculating radiouptake. Myocardial uptake for 99 Tc m -N-DBODC5 is high. Though myocardial uptake was lower than 99 Tc m -MIBI, the liver clearance for 99 Tc m -N-DBODC5 was more rapid than that of 99 Tc m MIBI. As early as 30 min after injection, 99 Tc m -N-DBODC5 heart-to-liver ratio is 0.98 ± 0.52 versus 0.56 ± 0.19 for 99 Tc m -MIBI (P 99 Tc m -N-DBODC5 heart-to-liver ratio improved to the peak value (1.18 ± 0.57), compared with 0.71 ± 0.29 for 99 Tc m -MIBI, P 99 Tc m - N-DBODC5 was keeping at a high level until 180 min. 99 Tc m -N-DBODC5 exhibited rapid lung clearance, similar to that of 99 Tc m -MIBI. The biodistribution in the isolated organs demonstrated the same trend. The rapid 99 Tc m -N-DBODC5 liver clearance may allow the earlier imaging, and overcome the photon scatter from the liver with high activity which interfered the inferoapical wall in myocardial images. 99 Tc m -N-DBODC5 is a promising new myocardial perfusion imaging agent with superior biodistribution properties. (authors)

  7. Nonclinical Profile of BLZ-100, a Tumor-Targeting Fluorescent Imaging Agent.

    Parrish-Novak, Julia; Byrnes-Blake, Kelly; Lalayeva, Narine; Burleson, Stefanie; Fidel, Janean; Gilmore, Rhonda; Gayheart-Walsten, Pamela; Bricker, Gregory A; Crumb, William J; Tarlo, K S; Hansen, Stacey; Wiss, Valorie; Malta, Errol; Dernell, William S; Olson, James M; Miller, Dennis M

    BLZ-100 is a single intravenous use, fluorescent imaging agent that labels tumor tissue to enable more complete and precise surgical resection. It is composed of a chlorotoxin peptide covalently bound to the near-infrared fluorophore indocyanine green. BLZ-100 is in clinical development for intraoperative visualization of human tumors. The nonclinical safety and pharmacokinetic (PK) profile of BLZ-100 was evaluated in mice, rats, canines, and nonhuman primates (NHP). Single bolus intravenous administration of BLZ-100 was well tolerated, and no adverse changes were observed in cardiovascular safety pharmacology, PK, and toxicology studies in rats and NHP. The single-dose no-observed-adverse-effect-levels (NOAELs) were 7 mg (28 mg/kg) in rats and 60 mg (20 mg/kg) in NHP, corresponding to peak concentration values of 89 400 and 436 000 ng/mL and area-under-the-curve exposure values of 130 000 and 1 240 000 h·ng/mL, respectively. Based on a human imaging dose of 3 mg, dose safety margins are >100 for rat and monkey. BLZ-100 produced hypersensitivity reactions in canine imaging studies (lethargy, pruritus, swollen muzzle, etc). The severity of the reactions was not dose related. In a follow-up study in dogs, plasma histamine concentrations were increased 5 to 60 minutes after BLZ-100 injection; this coincided with signs of hypersensitivity, supporting the conclusion that the reactions were histamine based. Hypersensitivity reactions were not observed in other species or in BLZ-100 human clinical studies conducted to date. The combined imaging, safety pharmacology, PK, and toxicology studies contributed to an extensive initial nonclinical profile for BLZ-100, supporting first-in-human clinical trials.

  8. pH imaging of mouse kidneys in vivo using a frequency-dependent paraCEST agent

    Wu, Yunkou; Zhang, Shanrong; Soesbe, Todd C.; Yu, Jing; Vinogradov, Elena; Lenkinski, Robert E.; Sherry, A. Dean

    2015-01-01

    Purpose This study explored the feasibility of using a pH responsive paraCEST agent to image the pH gradient in kidneys of healthy mice. Methods CEST signals were acquired on an Agilent 9.4 T small animal MRI system using a steady-state gradient echo pulse sequence after a bolus injection of agent. The magnetic field inhomogeneity across each kidney was corrected using the WASSR method and pH maps were calculated by measuring the frequency of water exchange signal arising from the agent. Results Dynamic CEST studies demonstrated that the agent was readily detectable in kidneys only between 4 to 12 min post-injection. The CEST images showed a higher signal intensity in the pelvis and calyx regions and lower signal intensity in the medulla and cortex regions. The pH maps reflected tissue pH values spanning from 6.0 to 7.5 in kidneys of healthy mice. Conclusion This study demonstrated that pH maps of the kidney can be imaged in vivo by measuring the pH-dependent chemical shift of a single water exchange CEST peak without prior knowledge of the agent concentration in vivo. The results demonstrate the potential of using a simple frequency-dependent paraCEST agent for mapping tissue pH in vivo. PMID:26173637

  9. Synthesis Of Gd-dtpa-folat For Magnetic Resonance Imaging Contrast Agent And Characterization By Using 153gd-dtpa-folate Radioactive

    G., Adang H; S., Yono; Maskur

    2012-01-01

    Contrast agent was used to clarify the image of the organ that is difficult to distinguish by MRI (Magnetic Resonance Imaging) techniques, particularly in soft tissues of the central nervous system, liver, digestive system, lymphatic system, breast, cardiovascular and pulmonary systems. One of the commonly used contrast agents in hospitals is Gadolinium-DieThylenetriamine Pentaacetic Acid (Gd-DTPA). Gd-DTPA is non specific contrast agent, therefore it has led to develop a contrast agent that ...

  10. A targeted nanoglobular contrast agent from host-guest self-assembly for MR cancer molecular imaging.

    Zhou, Zhuxian; Han, Zhen; Lu, Zheng-Rong

    2016-04-01

    The clinical application of nanoparticular Gd(III) based contrast agents for tumor molecular MRI has been hindered by safety concerns associated with prolonged tissue retention, although they can produce strong tumor enhancement. In this study, a targeted well-defined cyclodextrin-based nanoglobular contrast agent was developed through self-assembly driven by host-guest interactions for safe and effective cancer molecular MRI. Multiple β-cyclodextrins attached POSS (polyhedral oligomeric silsesquioxane) nanoglobule was used as host molecule. Adamantane-modified macrocyclic Gd(III) contrast agent, cRGD (cyclic RGDfK peptide) targeting ligand and fluorescent probe was used as guest molecules. The targeted host-guest nanoglobular contrast agent cRGD-POSS-βCD-(DOTA-Gd) specifically bond to αvβ3 integrin in malignant 4T1 breast tumor and provided greater contrast enhancement than the corresponding non-targeted agent. The agent also provided significant fluorescence signal in tumor tissue. The histological analysis of the tumor tissue confirmed its specific and effective targeting to αvβ3 integrin. The targeted imaging agent has a potential for specific cancer molecular MR and fluorescent imaging. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Hepato-biliary effects of mucoviscidosis: use of Mebrofenine scintigraphy

    Perrin-Fayolle, O.; Morelec, I.; Gilly, R.; Roche, S.; Sappey-Marinier, D.; Briere, J.; Bonmartin, A.; Bellon, G.

    1997-01-01

    The objective of this work is the scintigraphic profile of patients afflicted with mucoviscidosis with portal hypertension (PHT) and the questions whether there exists a criterion to characterized the first stage of fibrosis as well as whether exist in this stage lesions of hepato cellular insufficiency (HCI). The method of the work implied the study of the dynamics of 60 minutes after injecting 40 - 120 MBq of Mebrofenine in 18 patients, 9 presenting a certain PHT, and 9, signs of hepatobiliary affliction without genuine PHT. In the population with PHT, all patients presented a splenomegaly, a very heterogeneous fixation and a retention of the tracer in the intrahepatic-biliary tracts (IHBT) with augmentation of T 1/2 in 5 cases; 8 presented a diminution of the hepatic extraction fraction (HEF), serving as control of HCI. In the population without PHT 2 patients are normal. In the other seven, the most frequently found anomalies are the accumulation of tracer in the IHBT (5/7) and the hepatic heterogeneity (4/7). HEF is low in one case. No dilatation was visible by echography. In conclusion, the accumulation in the IHBT (14 patients, 9 PHT and 5 non PHT) expresses the presence of a functional stasis without organic effects (no echographic dilatation), consequence of a obstruction of biliary ducts by mucus plugs due to dehydration of the bile. The HEF, labeller of HCI, is low in 8 PHT and in one non-PHT, hence tardy in the evolution of the disease, the portal cirrhosis occurring at more on less long term. This parameter can not be considered as a labeller of fibrosis, on the contrary, the accumulation of this tracer in the IHBT and the hepatic heterogeneity seems more interesting for an early detection and start of a preventive treatment

  12. Simple method for quantification of gadolinium magnetic resonance imaging contrast agents using ESR spectroscopy.

    Takeshita, Keizo; Kinoshita, Shota; Okazaki, Shoko

    2012-01-01

    To develop an estimation method of gadolinium magnetic resonance imaging (MRI) contrast agents, the effect of concentration of Gd compounds on the ESR spectrum of nitroxyl radical was examined. A solution of either 4-oxo-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPONE) or 4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPOL) was mixed with a solution of Gd compound and the ESR spectrum was recorded. Increased concentration of gadolinium-diethylenetriamine pentaacetic acid chelate (Gd-DTPA), an MRI contrast agent, increased the peak-to-peak line widths of ESR spectra of the nitroxyl radicals, in accordance with a decrease of their signal heights. A linear relationship was observed between concentration of Gd-DTPA and line width of ESR signal, up to approximately 50 mmol/L Gd-DTPA, with a high correlation coefficient. Response of TEMPONE was 1.4-times higher than that of TEMPOL as evaluated from the slopes of the lines. The response was slightly different among Gd compounds; the slopes of calibration curves for acua[N,N-bis[2-[(carboxymethyl)[(methylcarbamoyl)methyl]amino]ethyl]glycinato(3-)]gadolinium hydrate (Gd-DTPA-BMA) (6.22 μT·L/mmol) and gadolinium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid chelate (Gd-DOTA) (6.62 μT·L/mmol) were steeper than the slope for Gd-DTPA (5.45 μT·L/mmol), whereas the slope for gadolinium chloride (4.94 μT·L/mmol) was less steep than that for Gd-DTPA. This method is simple to apply. The results indicate that this method is useful for rough estimation of the concentration of Gd contrast agents if calibration is carried out with each standard compound. It was also found that the plot of the reciprocal square root of signal height against concentrations of contrast agents could be useful for the estimation if a constant volume of sample solution is taken and measured at the same position in the ESR cavity every time.

  13. Biological evaluation of 99mTC cis-Pt iminoacetic acid complexes as tumour imaging agents

    Awaluddin, A.; Jacobs, J.J.; Bourne, D.W.; Maddalena, D.J.; Wilson, J.G.; Boyd, D.W.

    1987-01-01

    The biodistributions of three new 99m Tc labelled cis-platinum bifunctional tumour imaging agents were examined in mice bearing a certain type of sarcoma between 15 minutes and 24 hours post injection. The three complexes were excreted primarily via the renal pathway into the urine but at quite different rates. All complexes had some affinity for the tumour, but complexes III had the greatest, with tumour to blood and tumour to muscle rates at 24 hours in excess of 10:1 and 18:1. Biodistribution results were calculated using Tiscon Program. Suggesting that the three complexes may be useful as tumour imaging agents. (M.E.L.) [es

  14. Comparison of traditional methods with 3D computer models in the instruction of hepatobiliary anatomy.

    Keedy, Alexander W; Durack, Jeremy C; Sandhu, Parmbir; Chen, Eric M; O'Sullivan, Patricia S; Breiman, Richard S

    2011-01-01

    This study was designed to determine whether an interactive three-dimensional presentation depicting liver and biliary anatomy is more effective for teaching medical students than a traditional textbook format presentation of the same material. Forty-six medical students volunteered for participation in this study. Baseline demographic information, spatial ability, and knowledge of relevant anatomy were measured. Participants were randomized into two groups and presented with a computer-based interactive learning module comprised of animations and still images to highlight various anatomical structures (3D group), or a computer-based text document containing the same images and text without animation or interactive features (2D group). Following each teaching module, students completed a satisfaction survey and nine-item anatomic knowledge post-test. The 3D group scored higher on the post-test than the 2D group, with a mean score of 74% and 64%, respectively; however, when baseline differences in pretest scores were accounted for, this difference was not statistically significant (P = 0.33). Spatial ability did not statistically significantly correlate with post-test scores for the 3D group or the 2D group. In the post-test satisfaction survey the 3D group expressed a statistically significantly higher overall satisfaction rating compared to students in the 2D control group (4.5 versus 3.7 out of 5, P = 0.02). While the interactive 3D multimedia module received higher satisfaction ratings from students, it neither enhanced nor inhibited learning of complex hepatobiliary anatomy compared to an informationally equivalent traditional textbook style approach. . Copyright © 2011 American Association of Anatomists.

  15. New radioiodinated carboxylic and hydroxamic matrix metalloproteinase inhibitor tracers as potential tumor imaging agents

    Oltenfreiter, Ruth E-mail: ruth.oltenfreiter@rug.ac.be; Staelens, Ludovicus; Lejeune, Annabelle; Dumont, Filip; Frankenne, Francis; Foidart, Jean-Michel; Slegers, Guido

    2004-05-01

    Several studies have demonstrated a positive correlation between tumor progression and expression of extracellular proteinases such as matrix metalloproteinases (MMPs). MMP-2 and MMP-9 have become attractive targets for cancer research because of their increased expression in human malignant tumor tissues of various organs, providing a target for medical imaging techniques. Radioiodinated carboxylic and hydroxamic MMP inhibitors 2-(4'-[{sup 123}I]iodo-biphenyl-4-sulfonylamino)-3-(1H-indol-3-yl)-propionic acid (9) and 2-(4'-[{sup 123}I]iodo-biphenyl-4-sulfonylamino)-3-(1H-indol-3-yl)-propionamide (11) were synthesized by electrophilic aromatic substitution of the tributylstannyl derivatives and resulted in radiochemical yields of 60% {+-} 5% (n = 3) and 70% {+-} 5% (n = 6), respectively. In vitro zymography and enzyme assays showed high inhibition capacities of the inhibitors on gelatinases. In vivo biodistribution showed no long-term accumulation in organs and the possibility to accumulate in the tumor. These results warrant further studies of radioiodinated carboxylic and hydroxamic MMP inhibitor tracers as potential SPECT tumor imaging agents.

  16. New radioiodinated carboxylic and hydroxamic matrix metalloproteinase inhibitor tracers as potential tumor imaging agents

    Oltenfreiter, Ruth; Staelens, Ludovicus; Lejeune, Annabelle; Dumont, Filip; Frankenne, Francis; Foidart, Jean-Michel; Slegers, Guido

    2004-01-01

    Several studies have demonstrated a positive correlation between tumor progression and expression of extracellular proteinases such as matrix metalloproteinases (MMPs). MMP-2 and MMP-9 have become attractive targets for cancer research because of their increased expression in human malignant tumor tissues of various organs, providing a target for medical imaging techniques. Radioiodinated carboxylic and hydroxamic MMP inhibitors 2-(4'-[ 123 I]iodo-biphenyl-4-sulfonylamino)-3-(1H-indol-3-yl)-propionic acid (9) and 2-(4'-[ 123 I]iodo-biphenyl-4-sulfonylamino)-3-(1H-indol-3-yl)-propionamide (11) were synthesized by electrophilic aromatic substitution of the tributylstannyl derivatives and resulted in radiochemical yields of 60% ± 5% (n = 3) and 70% ± 5% (n = 6), respectively. In vitro zymography and enzyme assays showed high inhibition capacities of the inhibitors on gelatinases. In vivo biodistribution showed no long-term accumulation in organs and the possibility to accumulate in the tumor. These results warrant further studies of radioiodinated carboxylic and hydroxamic MMP inhibitor tracers as potential SPECT tumor imaging agents

  17. Self-Assembled Polyelectrolyte Nanoparticles as Fluorophore-Free Contrast Agents for Multicolor Optical Imaging

    Da Hye Shin

    2015-03-01

    Full Text Available In this work, we describe the fabrication of self-assembled polyelectrolyte nanoparticles that provide a multicolor optical imaging modality. Poly(γ-glutamic acid(γ-PGA formed self-assembled nanoparticles through electrostatic interactions with two different cationic polymers: poly(L-lysine(PLL and chitosan. The self-assembled γ-PGA/PLL and γ-PGA/chitosan nanoparticles were crosslinked by glutaraldehyde. Crosslinking of the ionic self-assembled nanoparticles with glutaraldehyde not only stabilized the nanoparticles but also generated a strong autofluorescence signal. Fluorescent Schiff base bonds (C=N and double bonds (C=C were generated simultaneously by crosslinking of the amine moiety of the cationic polyelectrolytes with monomeric glutaraldehyde or with polymeric glutaraldehyde. The unique optical properties of the nanoparticles that resulted from the crosslinking by glutaraldehyde were analyzed using UV/Vis and fluorescence spectroscopy. We observed that the fluorescence intensity of the nanoparticles could be regulated by adjusting the crosslinker concentration and the reaction time. The nanoparticles also exhibited high performance in the labeling and monitoring of therapeutic immune cells (macrophages and dendritic cells. These self-assembled nanoparticles are expected to be a promising multicolor optical imaging contrast agent for the labeling, detection, and monitoring of cells.

  18. Technetium-99m dextran: a promising new protein-losing enteropathy imaging agent

    Bhatnagar, A.; Singh, A.K.; Lahoti, D.; Singh, T.; Khanna, C.M.

    1996-01-01

    The purpose of this study was to evaluate technetium-99m dextran ( 99m Tc-Dx; molecular weight 81000) as a prospective protein-losing enteropathy (PLE) imaging agent. Twenty-two patients iwth diseases commonly associated with PLE and 12 healthy control subjects underwent intravenous 99m Tc-Dx scintigraphy. All of the 22 test patients showed significant radiotracer accumulation in the intestines within 3-4 h post injection. The focal, regional or generalised nature of the enteropathy and involvement of the large or small intestine could be identified in most cases. Four of the 12 apparently healthy subjects also showed minimal accumulation in the abdominal area occurring late in the study period. This could have been physiological, related to food habits or due to unsuspected intestinal worms. We attribute the high sensitivity of 99m Tc-Dx to its relatively fast blood (background) clearance. The radiotracer may have several other advantages over 99m Tc-labelled human serum albumin in imaging PLE. (orig.)

  19. Plasmon-resonant nanorods as multimodal agents for two-photon luminescent imaging and photothermal therapy

    Huff, Terry B.; Hansen, Matthew N.; Tong, Ling; Zhao, Yan; Wang, Haifeng; Zweifel, Daniel A.; Cheng, Ji-Xin; Wei, Alexander

    2007-02-01

    Plasmon-resonant gold nanorods have outstanding potential as multifunctional agents for image-guided therapies. Nanorods have large absorption cross sections at near-infrared (NIR) frequencies, and produce two-photon luminescence (TPL) when excited by fs-pulsed laser irradiation. The TPL signals can be detected with single-particle sensitivity, enabling nanorods to be imaged in vivo while passing through blood vessels at subpicomolar concentrations. Furthermore, cells labeled with nanorods become highly susceptible to photothermal damage when irradiated at plasmon resonance, often resulting in a dramatic blebbing of the cell membrane. However, the straightforward application of gold nanorods for cell-specific labeling is obstructed by the presence of CTAB, a cationic surfactant carried over from nanorod synthesis which also promotes their nonspecific uptake into cells. Careful exchange and replacement of CTAB can be achieved by introducing oligoethyleneglycol (OEG) units capable of chemisorption onto nanorod surfaces by in situ dithiocarbamate formation, a novel method of surface functionalization. Nanorods with a dense coating of methyl-terminated OEG chains are shielded from nonspecific cell uptake, whereas nanorods functionalized with folate-terminated OEG chains accumulate on the surface of tumor cells overexpressing their cognate receptor, with subsequent delivery of photoinduced cell damage at low laser fluence.

  20. Porphyrin-containing polyaspartamide gadolinium complexes as potential magnetic resonance imaging contrast agents.

    Yan, Guo-Ping; Li, Zhen; Xu, Wei; Zhou, Cheng-Kai; Yang, Lian; Zhang, Qiao; Li, Liang; Liu, Fan; Han, Lin; Ge, Yuan-Xing; Guo, Jun-Fang

    2011-04-04

    Porphyrin-containing polyaspartamide ligands (APTSPP-PHEA-DTPA) were synthesized by the incorporation of diethylenetriaminepentaacetic acid (DTPA) and 5-(4'-aminophenyl)-10,15,20-tris(4'-sulfonatophenyl) porphyrin, trisodium salt (APTSPP) into poly-α,β-[N-(2-hydroxyethyl)-l-aspartamide] (PHEA). These ligands were further reacted with gadolinium chloride to produce macromolecule-gadolinium complexes (APTSPP-PHEA-DTPA-Gd). Experimental data of (1)H NMR, IR, UV and elemental analysis evidenced the formation of the polyaspartamide ligands and gadolinium complexes. In vitro and in vivo property tests indicated that APTSPP-PHEA-DTPA-Gd possessed noticeably higher relaxation effectiveness, less toxicity to HeLa cells, and significantly higher enhanced signal intensities (SI) of the VX2 carcinoma in rabbits with lower injection dose requirement than that of Gd-DTPA. Moreover, APTSPP-PHEA-DTPA-Gd was found to greatly enhance the contrast of MR images of the VX2 carcinoma, providing prolonged intravascular duration, and distinguished the VX2 carcinoma and normal tissues in rabbits according to MR image signal enhancements. These porphyrin-containing polyaspartamide gadolinium complexes can be used as the candidates of contrast agents for targeted MRI to tumors. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  1. Radiolabelling and evaluation of novel haloethylsulfoxides as PET imaging agents for tumor hypoxia

    Laurens, Evelyn; Yeoh, Shinn Dee; Rigopoulos, Angela; Cao, Diana; Cartwright, Glenn A.; O'Keefe, Graeme J.; Tochon-Danguy, Henri J.; White, Jonathan M.; Scott, Andrew M.; Ackermann, Uwe

    2012-01-01

    The significance of imaging hypoxia with the PET ligand [ 18 F]FMISO has been demonstrated in a variety of cancers. However, the slow kinetics of [ 18 F]FMISO require a 2-h delay between tracer administration and patient scanning. Labelled chloroethyl sulfoxides have shown faster kinetics and higher contrast than [ 18 F]FMISO in a rat model of ischemic stroke. However, these nitrogen mustard analogues are unsuitable for routine production and use in humans. Here we report on the synthesis and in vitro and in vivo evaluation of two novel sulfoxides which we synthesised from a single precursor molecule via either 2-[ 18 F]fluoroethyl azide click chemistry or conventional nucleophilic displacement of a chloride leaving group. The yields of the click chemistry approach were 90±5% of [ 18 F] based on 2-[ 18 F]fluoroethyl azide, and the yields for the S N reaction were 15±5% of [ 18 F] based on K[ 18 F]F. Both radiotracers underwent metabolism in an in vitro assay using S9 liver fractions with biological half-lives of 32.39 and 43.32 min, respectively. Imaging studies using an SK-RC-52 tumor model in BALB/c nude mice have revealed that only [ 18 F] is retained in hypoxic tumors, whereas [ 18 F] is cleared from those tumors at a rate similar to that of muscle tissue. [ 18 F] has emerged as a promising new lead structure for further development of sulfoxide-based hypoxia imaging agents. In particular, the mechanism of uptake needs to be elucidated and changes to the chemical structure need to be made in order to reduce metabolism and improve radiotracer kinetics.

  2. Preparation and evaluation of 68Ga-ECC as a PET renal imaging agent

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro; Geramifar, Patham; Beiki, Davood

    2015-01-01

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop 68 Ga-ethylenecysteamine cysteine ( 68 Ga-ECC). Ga-ECC was prepared using generator-based 68 GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). 68 Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV max ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous 99m Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time

  3. Preparation and evaluation of {sup 68}Ga-ECC as a PET renal imaging agent

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro [Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Geramifar, Patham; Beiki, Davood [Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2015-09-15

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop {sup 68}Ga-ethylenecysteamine cysteine ({sup 68}Ga-ECC). Ga-ECC was prepared using generator-based {sup 68}GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). {sup 68}Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV{sub max} ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous {sup 99m}Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time.

  4. Valine-based biphenylsulphonamide matrix metalloproteinase inhibitors as tumor imaging agents

    Oltenfreiter, Ruth [Faculty of Pharmaceutical Sciences, Department of Radiopharmacy, Ghent University, Harelbekestraat 72, 9000 Ghent (Belgium)]. E-mail: ruth.oltenfreiter@ugent.be; Staelens, Ludovicus [Faculty of Pharmaceutical Sciences, Department of Radiopharmacy, Ghent University, Harelbekestraat 72, 9000 Ghent (Belgium); Kersemans, Veerle [Faculty of Pharmaceutical Sciences, Department of Radiopharmacy, Ghent University, Harelbekestraat 72, 9000 Ghent (Belgium); Cornelissen, Bart [Faculty of Pharmaceutical Sciences, Department of Radiopharmacy, Ghent University, Harelbekestraat 72, 9000 Ghent (Belgium); Frankenne, Francis [Laboratory of Tumor and Developmental Biology, University of Liege, Sart-Tilman, Liege (Belgium); Foidart, Jean-Michel [Laboratory of Tumor and Developmental Biology, University of Liege, Sart-Tilman, Liege (Belgium); Wiele, Christophe van de [Division of Nuclear Medicine, Gent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Slegers, Guido [Faculty of Pharmaceutical Sciences, Department of Radiopharmacy, Ghent University, Harelbekestraat 72, 9000 Ghent (Belgium)

    2006-06-15

    Among matrix metalloproteinases (MMPs), the subfamily of gelatinases (MMP-2, MMP-9) is of particular interest due to their ability to degrade type IV collagen and other non-fibrillar collagen domains and proteins such as fibronectin and laminin. Whilst malignant cells often over-express various MMPs, the gelatinases have been most consistently detected in malignant tissues and associated with tumor growth, metastatic potential and angiogenesis. Radiosynthesis of carboxylic (1') and hydroxamic (2') MMPIs resulted in radiochemical yields of 70+/-5% (n=6) and 60+/-5% (n=4), respectively. Evaluation in A549-inoculated athymic mice showed a tumor uptake of 2.0+/-0.7%ID/g (3h p.i.), a tumor/blood ratio of 0.5 and a tumor/muscle ratio of 4.6 at 48hp.i. for 1'. For compound 2' a tumor uptake of 0.7+/-0.2%ID/g (3hp.i.), a tumor/blood ratio of 1.2 and a tumor/muscle ratio of 1.8 at 24hp.i. were observed. HPLC analysis of the blood (plasma) showed no dehalogenation or other metabolites of 1' 2hp.i. For compound 2', 65.4% of intact compound was found in the blood (plasma) and one polar metabolite (31%) was detected whereas in the tumor 91.8% of the accumulated activity was caused by intact compound and only 8.1% by the metabolite. Planar imaging, using a Toshiba GCA-9300A/hg SPECT camera, showed that tumor tissue could be visualized and that image quality improved by decreasing specific activity resulting in lower liver uptake, indicating some degree of saturable binding in the liver. In vivo evaluation of these radioiodinated carboxylic and hydroxamic MMP inhibitor tracers revealed that MMP inhibitors could have potential as tumor imaging agents, but that further research is necessary.

  5. Valine-based biphenylsulphonamide matrix metalloproteinase inhibitors as tumor imaging agents

    Oltenfreiter, Ruth; Staelens, Ludovicus; Kersemans, Veerle; Cornelissen, Bart; Frankenne, Francis; Foidart, Jean-Michel; Wiele, Christophe van de; Slegers, Guido

    2006-01-01

    Among matrix metalloproteinases (MMPs), the subfamily of gelatinases (MMP-2, MMP-9) is of particular interest due to their ability to degrade type IV collagen and other non-fibrillar collagen domains and proteins such as fibronectin and laminin. Whilst malignant cells often over-express various MMPs, the gelatinases have been most consistently detected in malignant tissues and associated with tumor growth, metastatic potential and angiogenesis. Radiosynthesis of carboxylic (1') and hydroxamic (2') MMPIs resulted in radiochemical yields of 70+/-5% (n=6) and 60+/-5% (n=4), respectively. Evaluation in A549-inoculated athymic mice showed a tumor uptake of 2.0+/-0.7%ID/g (3h p.i.), a tumor/blood ratio of 0.5 and a tumor/muscle ratio of 4.6 at 48hp.i. for 1'. For compound 2' a tumor uptake of 0.7+/-0.2%ID/g (3hp.i.), a tumor/blood ratio of 1.2 and a tumor/muscle ratio of 1.8 at 24hp.i. were observed. HPLC analysis of the blood (plasma) showed no dehalogenation or other metabolites of 1' 2hp.i. For compound 2', 65.4% of intact compound was found in the blood (plasma) and one polar metabolite (31%) was detected whereas in the tumor 91.8% of the accumulated activity was caused by intact compound and only 8.1% by the metabolite. Planar imaging, using a Toshiba GCA-9300A/hg SPECT camera, showed that tumor tissue could be visualized and that image quality improved by decreasing specific activity resulting in lower liver uptake, indicating some degree of saturable binding in the liver. In vivo evaluation of these radioiodinated carboxylic and hydroxamic MMP inhibitor tracers revealed that MMP inhibitors could have potential as tumor imaging agents, but that further research is necessary

  6. Radioiodination of central nerves system dopamine D2 receptor imaging agent. IBZM preparation and preclinical study

    Lin Yansong; Lin Xiangtong; Hu Mingyang; Pan Shangren; Wang Bocheng

    1996-01-01

    To study preparation of central nerves system dopamine D2 imaging agent 131 I-IBZM and its preclinical investigation, peracetic acid was used as the oxidant for preparing radioiodinated 125 I-IBZM and 131 I-IBZM, D2 binding properties of IBZM were examined by in vitro binding saturation analysis, rat whole body and regional brain biodistribution, rat brain autoradiography and rabbit SPECT static imaging, etc. The results are: 1. The radiolabelling yields of 125 I-IBZM and 131 I-IBZM were 84.18% +- 3.06% and 78.50% +- 3.47%. The radiochemical purity were over 95% after being isolated by HPLC; and were over 90% after being isolated by organic extraction. 2. Scatchard plot of D2 receptor saturation binding analysis showed: K d = 0.53 +- 0.06 nmol/L, B max = 466.45 +- 45.88 fmol/mg protein. 3. The rat brain autoradiography and analysis showed that there was high 125 I-IBZM uptake in striatal area 2 hr after injection, the striatal/cerebellum ratio was 6.22 +- 0.48; the high 125 -IBZM uptake can be blocked by haloperidol--a special dopamine D2 receptor antagonist. 4. 131 I-IBZM rat biodistribution and rabbit SPECT planar imaging showed good initial brain uptake and retention, the initial uptake of rat brain was 1.893 +- 0.147% ID/g at 2 min and 1.044 +- 0.135% ID/g at 60 min. The results showed that the radioiodinated IBZM had high affinity, saturation and specificity to rat's and rabbit's central nerves system dopamine D2 receptors

  7. Radioiodination of central nerves system dopamine D2 receptor imaging agent. IBZM preparation and preclinical study

    Yansong, Lin; Xiangtong, Lin; Mingyang, Hu; Shangren, Pan; Bocheng, Wang [Huashan Hospital of Shanghai Medical Univ., Shanghai (China)

    1996-11-01

    To study preparation of central nerves system dopamine D2 imaging agent {sup 131}I-IBZM and its preclinical investigation, peracetic acid was used as the oxidant for preparing radioiodinated {sup 125}I-IBZM and {sup 131}I-IBZM, D2 binding properties of IBZM were examined by in vitro binding saturation analysis, rat whole body and regional brain biodistribution, rat brain autoradiography and rabbit SPECT static imaging, etc. The results are: 1. The radiolabelling yields of {sup 125}I-IBZM and {sup 131}I-IBZM were 84.18% +- 3.06% and 78.50% +- 3.47%. The radiochemical purity were over 95% after being isolated by HPLC; and were over 90% after being isolated by organic extraction. 2. Scatchard plot of D2 receptor saturation binding analysis showed: K{sub d} = 0.53 +- 0.06 nmol/L, B{sub max} = 466.45 +- 45.88 fmol/mg protein. 3. The rat brain autoradiography and analysis showed that there was high {sup 125}I-IBZM uptake in striatal area 2 hr after injection, the striatal/cerebellum ratio was 6.22 +- 0.48; the high {sup 125}-IBZM uptake can be blocked by haloperidol--a special dopamine D2 receptor antagonist. 4. {sup 131}I-IBZM rat biodistribution and rabbit SPECT planar imaging showed good initial brain uptake and retention, the initial uptake of rat brain was 1.893 +- 0.147% ID/g at 2 min and 1.044 +- 0.135% ID/g at 60 min. The results showed that the radioiodinated IBZM had high affinity, saturation and specificity to rat`s and rabbit`s central nerves system dopamine D2 receptors.

  8. Technique: imaging earliest tooth development in 3D using a silver-based tissue contrast agent.

    Raj, Muhammad T; Prusinkiewicz, Martin; Cooper, David M L; George, Belev; Webb, M Adam; Boughner, Julia C

    2014-02-01

    Looking in microscopic detail at the 3D organization of initiating teeth within the embryonic jaw has long-proved technologically challenging because of the radio-translucency of these tiny un-mineralized oral tissues. Yet 3D image data showing changes in the physical relationships among developing tooth and jaw tissues are vital to understand the coordinated morphogenesis of vertebrate teeth and jaws as an animal grows and as species evolve. Here, we present a new synchrotron-based scanning solution to image odontogenesis in 3D and in histological detail using a silver-based contrast agent. We stained fixed, intact wild-type mice aged embryonic (E) day 10 to birth with 1% Protargol-S at 37°C for 12-32 hr. Specimens were scanned at 4-10 µm pixel size at 28 keV, just above the silver K-edge, using micro-computed tomography (µCT) at the Canadian Light Source synchrotron. Synchrotron µCT scans of silver-stained embryos showed even the earliest visible stages of tooth initiation, as well as many other tissue types and structures, in histological detail. Silver stain penetration was optimal for imaging structures in intact embryos E15 and younger. This silver stain method offers a powerful yet straightforward approach to visualize at high-resolution and in 3D the earliest stages of odontogenesis in situ, and demonstrates the important of studying the tooth organ in all three planes of view. Copyright © 2013 Wiley Periodicals, Inc.

  9. A study on hepato-biliary and alimentary scintigram by means of triple tracer method

    Aibata, Hirofumi; Torizumi, Kazutami; Okada, Takashi; Kiji, Shigeyuki; Yamada, Ryusaku; Shimada, Kosuke; Taniguchi, Katsutoshi; Aoki, Yozo

    1987-01-01

    In order to evaluate the gastric emptying and postprandial mixing of bile with food, the scintigraphies of hepatobiliary and gastrointestinal tracts by using three different kinds of radioisotopes were performed simultaneously ( 99m Tc-E · HIDA for hepatobiliary scintigraphy, 111 In-DTPA containing orange juice and 131 I-albumin containing scrambled egg for gastrointestinal scintigraphy). This method was available for observation of gastric emptying of liquid and solid foods and also examination of the mixing effect of bile and food quantitatively. (author)

  10. Improved identification of cranial nerves using paired-agent imaging: topical staining protocol optimization through experimentation and simulation

    Torres, Veronica C.; Wilson, Todd; Staneviciute, Austeja; Byrne, Richard W.; Tichauer, Kenneth M.

    2018-03-01

    Skull base tumors are particularly difficult to visualize and access for surgeons because of the crowded environment and close proximity of vital structures, such as cranial nerves. As a result, accidental nerve damage is a significant concern and the likelihood of tumor recurrence is increased because of more conservative resections that attempt to avoid injuring these structures. In this study, a paired-agent imaging method with direct administration of fluorophores is applied to enhance cranial nerve identification. Here, a control imaging agent (ICG) accounts for non-specific uptake of the nerve-targeting agent (Oxazine 4), and ratiometric data analysis is employed to approximate binding potential (BP, a surrogate of targeted biomolecule concentration). For clinical relevance, animal experiments and simulations were conducted to identify parameters for an optimized stain and rinse protocol using the developed paired-agent method. Numerical methods were used to model the diffusive and kinetic behavior of the imaging agents in tissue, and simulation results revealed that there are various combinations of stain time and rinse number that provide improved contrast of cranial nerves, as suggested by optimal measures of BP and contrast-to-noise ratio.

  11. Pre-clinical evaluation of a nanoparticle-based blood-pool contrast agent for MR imaging of the placenta.

    Ghaghada, Ketan B; Starosolski, Zbigniew A; Bhayana, Saakshi; Stupin, Igor; Patel, Chandreshkumar V; Bhavane, Rohan C; Gao, Haijun; Bednov, Andrey; Yallampalli, Chandrasekhar; Belfort, Michael; George, Verghese; Annapragada, Ananth V

    2017-09-01

    Non-invasive 3D imaging that enables clear visualization of placental margins is of interest in the accurate diagnosis of placental pathologies. This study investigated if contrast-enhanced MRI performed using a liposomal gadolinium blood-pool contrast agent (liposomal-Gd) enables clear visualization of the placental margins and the placental-myometrial interface (retroplacental space). Non-contrast MRI and contrast-enhanced MRI using a clinically approved conventional contrast agent were used as comparators. Studies were performed in pregnant rats under an approved protocol. MRI was performed at 1T using a permanent magnet small animal scanner. Pre-contrast and post-liposomal-Gd contrast images were acquired using T1-weighted and T2-weighted sequences. Dynamic Contrast enhanced MRI (DCE-MRI) was performed using gadoterate meglumine (Gd-DOTA, Dotarem ® ). Visualization of the retroplacental clear space, a marker of normal placentation, was judged by a trained radiologist. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both single and averaged acquisitions. Images were reviewed by a radiologist and scored for the visualization of placental features. Contrast-enhanced CT (CE-CT) imaging using a liposomal CT agent was performed for confirmation of the MR findings. Transplacental transport of liposomal-Gd was evaluated by post-mortem elemental analysis of tissues. Ex-vivo studies in perfused human placentae from normal, GDM, and IUGR pregnancies evaluated the transport of liposomal agent across the human placental barrier. Post-contrast T1w images acquired with liposomal-Gd demonstrated significantly higher SNR (p = 0.0002) in the placenta compared to pre-contrast images (28.0 ± 4.7 vs. 6.9 ± 1.8). No significant differences (p = 0.39) were noted between SNR in pre-contrast and post-contrast liposomal-Gd images of the amniotic fluid, indicating absence of transplacental passage of the agent. The placental margins were

  12. New calcium-selective smart contrast agents for magnetic resonance imaging.

    Verma, Kirti Dhingra; Forgács, Attila; Uh, Hyounsoo; Beyerlein, Michael; Maier, Martin E; Petoud, Stéphane; Botta, Mauro; Logothetis, Nikos K

    2013-12-23

    Calcium plays a vital role in the human body and especially in the central nervous system. Precise maintenance of Ca(2+) levels is very crucial for normal cell physiology and health. The deregulation of calcium homeostasis can lead to neuronal cell death and brain damage. To study this functional role played by Ca(2+) in the brain noninvasively by using magnetic resonance imaging, we have synthesized a new set of Ca(2+) -sensitive smart contrast agents (CAs). The agents were found to be highly selective to Ca(2+) in the presence of other competitive anions and cations in buffer and in physiological fluids. The structure of CAs comprises Gd(3+)-DO3A (DO3A=1,4,7-tris(carboxymethyl)-1,4,7,10-tetraazacyclododecane) coupled to a Ca(2+) chelator o-amino phenol-N,N,O-triacetate (APTRA). The agents are designed to sense Ca(2+) present in extracellular fluid of the brain where its concentration is relatively high, that is, 1.2-0.8 mM. The determined dissociation constant of the CAs to Ca(2+) falls in the range required to sense and report changes in extracellular Ca(2+) levels followed by an increase in neural activity. In buffer, with the addition of Ca(2+) the increase in relaxivity ranged from 100-157%, the highest ever known for any T1-based Ca(2+)-sensitive smart CA. The CAs were analyzed extensively by the measurement of luminescence lifetime measurement on Tb(3+) analogues, nuclear magnetic relaxation dispersion (NMRD), and (17)O NMR transverse relaxation and shift experiments. The results obtained confirmed that the large relaxivity enhancement observed upon Ca(2+) addition is due to the increase of the hydration state of the complexes together with the slowing down of the molecular rotation and the retention of a significant contribution of the water molecules of the second sphere of hydration. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Oral gadopentetate dimeglumine administration as a negative gastrointestinal contrast agent to improve image quality of MR cholangiopancreatography

    Chen Yi; Xu Yikai; Zhao Yuhui; Wang Guisheng

    2008-01-01

    Objective: To choose optimal concentration and volume of Gd-DTPA solution as a oral gastrointestinal negative contrast agent for MRCP. To evaluate the role of Gd-DTPA solution in improving image quality of MRCP. Methods: In vitro experiment: Gd-DTPA solution was made with different concentrations. T 1 WI, T 2 WI, two-dimensional single slice fast spin echo sequence and three-dimensional half-fourier acquisition single-shot fast spin echo sequence were performed to measure the signal intensity of these contrast agents respectively, so Gd-DTPA solution with the optimal concentration can be decided as oral negative gastrointestinal contrast agent on MRCP. Clinical study: The Gd-DTPA solution with optimal concentration and volume was regarded as an oral negative gastrointestinal contrast agent of MRCP. Twenty- four' patients were performed with MRCP before and after (5-10 minutes and 10-15 minutes) administration of oral negative gastrointestinal contrast agent and image quality was analyzed. Statistical analysis was performed using analysis of variance with SPSS 10.0. Results: When the concentration of Gd-DTPA solution was ≤0.01 mol/L, the contrast agent was hyperintense on T 1 WI. On T 2 WI, when the concentration was ≥0.015 mol/L, it was as hypointense as basic ground; On 2D FSE MRCP images, controls were hyperintense and the contrast agent with concentration ranging from 0.0025 mol/L to 0.03 mol/L was hypointense. On 3D HEAST MRCP image, controls were hyperintense and when the concentration of Gd-DTPA was ≥0.01 mol, the contrast agent was hypointense. The Gd-DTPA solution with the concentration of 0.01 mol/L and the volume of 100 ml was chosen as MRCP oral negative gastrointestinal contrast agent. On MRCP images after oral administration of the contrast agent, in 10-15 minutes, the average grade scores within 24 patients of the intrahepatic bile duct, the common hepatic bile duct, the gall bladder, the common bile duct and pancreatic duct (the average grade

  14. Near infrared spectral polarization imaging of prostate cancer tissues using Cybesin: a receptor-targeted contrast agent

    Pu, Yang; Wang, W. B.; Tang, G. C.; Liang, Kexian; Achilefu, S.; Alfano, R. R.

    2013-03-01

    Cybesin, a smart contrast agent to target cancer cells, was investigated using a near infrared (NIR) spectral polarization imaging technique for prostate cancer detection. The approach relies on applying a contrast agent that can target cancer cells. Cybesin, as a small ICG-derivative dye-peptide, emit fluorescence between 750 nm and 900 nm, which is in the "tissue optical window". Cybesin was reported targeting the over-expressed bombesin receptors in cancer cells in animal model and the human prostate cancers over-expressing bombesin receptors. The NIR spectral polarization imaging study reported here demonstrated that Cybesin can be used as a smart optical biomarker and as a prostate cancer receptor targeted contrast agent.

  15. Carbon Nano-Allotrope/Magnetic Nanoparticle Hybrid Nanomaterials as T2 Contrast Agents for Magnetic Resonance Imaging Applications

    Yunxiang Gao

    2018-02-01

    Full Text Available Magnetic resonance imaging (MRI is the most powerful tool for deep penetration and high-quality 3D imaging of tissues with anatomical details. However, the sensitivity of the MRI technique is not as good as that of the radioactive or optical imaging methods. Carbon-based nanomaterials have attracted significant attention in biomaterial research in recent decades due to their unique physical properties, versatile functionalization chemistry, as well as excellent biological compatibility. Researchers have employed various carbon nano-allotropes to develop hybrid MRI contrast agents for improved sensitivity. This review summarizes the new research progresses in carbon-based hybrid MRI contrast agents, especially those reported in the past five years. The review will only focus on T2-weighted MRI agents and will be categorized by the different carbon allotrope types and magnetic components. Considering the strong trend in recent bio-nanotechnology research towards multifunctional diagnosis and therapy, carbon-based MRI contrast agents integrated with other imaging modalities or therapeutic functions are also covered.

  16. Multivalent contrast agents based on Gd-DTPA-terminated poly (propylene imine) dendrimers for Magnetic Resonance Imaging

    Langereis, S.; Lussanet, de Q.G; Genderen, van M.H.P.; Backes, W.H.; Meijer, E.W.

    2004-01-01

    A convenient methodol. has been developed for the synthesis of gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA)-terminated poly(propylene imine) dendrimers as contrast agents for magnetic resonance imaging (MRI). In our strategy, isocyanate-activated, tert-butyl-protected DTPA analogs were

  17. Radioiodinate labeling of atherosclerotic plaque imaging agent SP-4 and preliminary experiments

    Zhang, Y.; Wu, Z.

    2000-01-01

    SP-4 was oligopeptide contained 18 amino-acid. It was a part of apolipoprotein B. To study labeling SP-4 with 131 I and its clinical prospect as an atherosclerotic plaque imaging agent. SP-4 was synthesized by solid phase method and identified by amino acid analysis after purification with preparation-model HPLC. SP-4 was labeled with 131 I by the Chloramine-T method and purified through Sephadex G-25, then the radiochemical purity of 131 SP-4 and its stability in vitro were analyzed. 12 New Zealand rabbits were divided into atherosclerosis group (n=7, group A) and control group (n=5, group B). All of them were administrated with bovine serum albumen through i.v., then the rabbits of group A were fed on high cholesterol and high fat diet and group B, on normal diet. Purified 131 I-SP-4 was injected intravenously. %ID/g in blood and thoracic aorta and abdominal aorta at 4 hrs after injection and biodistribution of 131 I-SP-4 was investigated. The amino acid formation of the pure product was identified to be correct through amino-acid analysis. The radiochemical purity of 131 I-SP-4 was 96.2% after being purified, but less than 90% after being stored for 20 hrs. One of 7 rabbits in group A died after being fed for three weeks, the others were alive and atherosclerotic lesions were found after being fed for two mon. On the contrary, 5 rabbits in group B were visualized not to have atherosclerotic lesions. The uptakes of group A and group B at 4 hr after injection were 0.0378±0.0028 and 0.0371±0.038 in blood (p>0.05), 0.0882 ±0.0101 and 0.0276 ±0.0044 in abdominal aorta (p 131 I-SP-4 was mainly excreted through kidneys. SP-4 remained its biological activity after radioiodination and was located at atherosclerotic lesions. It was potentially useful as an atherosclerotic plaque imaging agent

  18. Development and evaluation of a novel radioiodinated vesamicol analog as a sigma receptor imaging agent.

    Ogawa, Kazuma; Kanbara, Hiroya; Shiba, Kazuhiro; Kitamura, Yoji; Kozaka, Takashi; Kiwada, Tatsuto; Odani, Akira

    2012-09-28

    Sigma receptors are highly expressed in human tumors and should be appropriate targets for developing tumor imaging agents. Previously, we synthesized a vesamicol analog, (+)-2-[4-(4-iodophenyl)piperidino]cyclohexanol ((+)-pIV), with a high affinity for sigma receptors and prepared radioiodinated (+)-pIV. As a result, (+)-[125I]pIV showed high tumor uptake in biodistribution experiments. However, the accumulation of radioactivity in normal tissues, such as the liver, was high. We supposed that some parts of the accumulation of (+)-pIV in the liver should be because of its high lipophilicity, and prepared and evaluated a more hydrophilic radiolabeled vesamicol analog, (+)-4-[1-(2-hydroxycyclohexyl)piperidine-4-yl]-2-iodophenol ((+)-IV-OH). (+)-[125I]IV-OH was prepared by the chloramine T method from the precursor. The partition coefficient of (+)-[125I]IV-OH was measured. Biodistribution experiments were performed by intravenous administration of a mixed solution of (+)-[125I]IV-OH and (+)-[131I]pIV into DU-145 tumor-bearing mice. Blocking studies were performed by intravenous injection of (+)-[125I]IV-OH mixed with an excess amount of ligand into DU-145 tumor-bearing mice. The hydrophilicity of (+)-[125I]IV-OH was much higher than that of (+)-[125I]pIV. In biodistribution experiments, (+)-[125I]IV-OH and (+)-[131I]pIV showed high uptake in tumor tissues at 10-min post-injection. Although (+)-[131I]pIV tended to be retained in most tissues, (+)-[125I]IV-OH was cleared from most tissues. In the liver, the radioactivity level of (+)-[125I]IV-OH was significantly lower at all time points compared to those of (+)-[131I]pIV. In the blocking studies, co-injection of an excess amount of sigma ligands resulted in significant decreases of tumor/blood uptake ratios after injection of (+)-[125I]IV-OH. The results indicate that radioiodinated (+)-IV-OH holds a potential as a sigma receptor imaging agent.

  19. Radiolabeled enzyme inhibitors and binding agents targeting PSMA: Effective theranostic tools for imaging and therapy of prostate cancer

    Pillai, Maroor Raghavan Ambikalmajan; Nanabala, Raviteja; Joy, Ajith; Sasikumar, Arun; Knapp, Furn F.

    2016-01-01

    Because of the broad incidence, morbidity and mortality associated with prostate-derived cancer, the development of more effective new technologies continues to be an important goal for the accurate detection and treatment of localized prostate cancer, lymphatic involvement and metastases. Prostate-specific membrane antigen (PSMA; Glycoprotein II) is expressed in high levels on prostate-derived cells and is an important target for visualization and treatment of prostate cancer. Radiolabeled peptide targeting technologies have rapidly evolved over the last decade and have focused on the successful development of radiolabeled small molecules that act as inhibitors to the binding of the N-acetyl-L-aspartyl-L-glutamate (NAAG) substrate to the PSMA molecule. A number of radiolabeled PSMA inhibitors have been described in the literature and labeled with SPECT, PET and therapeutic radionuclides. Clinical studies with these agents have demonstrated the improved potential of PSMA-targeted PET imaging agents to detect metastatic prostate cancer in comparison with conventional imaging technologies. Although many of these agents have been evaluated in humans, by far the most extensive clinical literature has described use of the 68 Ga and 177 Lu agents. This review describes the design and development of these agents, with a focus on the broad clinical introduction of PSMA targeting motifs labeled with 68 Ga for PET-CT imaging and 177 Lu for therapy. In particular, because of availability from the long-lived 68 Ge (T 1/2 = 270 days)/ 68 Ga (T 1/2 = 68 min) generator system and increasing availability of PET-CT, the 68 Ga-labeled PSMA targeted agent is receiving widespread interest and is one of the fastest growing radiopharmaceuticals for PET-CT imaging.

  20. "Smart" gold nanoparticles for photoacoustic imaging: an imaging contrast agent responsive to the cancer microenvironment and signal amplification via pH-induced aggregation.

    Song, Jaejung; Kim, Jeesu; Hwang, Sekyu; Jeon, Mansik; Jeong, Sanghwa; Kim, Chulhong; Kim, Sungjee

    2016-07-07

    'Smart' gold nanoparticles can respond to mild acidic environments, rapidly form aggregates, and shift the absorption to red and near-infrared. They were used as a photoacoustic imaging agent responsive to the cancer microenvironment, and have demonstrated the cancer-specific accumulation at the cellular level and an amplified signal which is twice higher than the control in vivo.

  1. Preparation of new technetium-99m NNS/X complexes and selection for brain imaging agent

    HE; Qiange; CHEN; Xiangji; MIAO; Yubin; LIU; Boli

    2004-01-01

    Based on excellent experiment results of 99mTcO-MPBDA-Cl, two new ligands MPTDA and MPDAA are synthesized. Then series of 99mTcO3+ complexes are prepared through adding different halide anions, followed by tests of physical chemistry qualities and biodistribution experiments. And results of these experiments show that complexes formed with MPTDA and MPDAA have better lipophilicity than those formed with MPBDA, still maintain the good brain retention ability of this type of compounds, but radioactivity uptake in blood is higher than that of 99mTcO-MPBDA and ratios of brain/blood are reduced. Obvious affections are fetched out on brain uptake and retention if fluoride, bromide or iodide anions are added. Results of experiments can be explained in reason with theoretic computation. It is confirmed that 99mTcO-MPBDA-Cl has potential to develop a new type of brain imaging agent considering integrated factors such as brain uptake, retention and toxicity.

  2. Solvation effects on brain uptakes of isomers of 99mTc brain imaging agents

    2002-01-01

    Analysis of electrostatic hydration free energies of the isomers of the 99mTc-BAT and 99mTc-DADT complexes is carried out using the computer simulation technique. The results show that not only a correlation exists between the logarithm of the brain uptake and the electrostatic hydration free energy for the isomers of 99mTc-brain radiopharmaceuticals, but also a linear relationship exists between the logarithm of the ratio of the brain uptake of the syn isomer to that of the anti one and the difference between the electrostatic hydration free energy of the syn-isomer and that of the anti one. Furthermore, the investigation on the important factors influencing the brain uptakes of 99mTc-radiopharmaceuticals and the reasons of the different biodistribution of the isomers of the 99mTc-complexes is explored at the molecular level. The results may provide a reference for the rational drug design of brain imaging agents.

  3. SERS-barcoded colloidal gold NP assemblies as imaging agents for use in biodiagnostics

    Dey, Priyanka; Olds, William; Blakey, Idriss; Thurecht, Kristofer J.; Izake, Emad L.; Fredericks, Peter M.

    2014-03-01

    There is a growing need for new biodiagnostics that combine high throughput with enhanced spatial resolution and sensitivity. Gold nanoparticle (NP) assemblies with sub-10 nm particle spacing have the benefits of improving detection sensitivity via Surface enhanced Raman scattering (SERS) and being of potential use in biomedicine due to their colloidal stability. A promising and versatile approach to form solution-stable NP assemblies involves the use of multi-branched molecular linkers which allows tailoring of the assembly size, hot-spot density and interparticle distance. We have shown that linkers with multiple anchoring end-groups can be successfully employed as a linker to assemble gold NPs into dimers, linear NP chains and clustered NP assemblies. These NP assemblies with diameters of 30-120 nm are stable in solution and perform better as SERS substrates compared with single gold NPs, due to an increased hot-spot density. Thus, tailored gold NP assemblies are potential candidates for use as biomedical imaging agents. We observed that the hot-spot density and in-turn the SERS enhancement is a function of the linker polymer concentration and polymer architecture. New deep Raman techniques like Spatially Offset Raman Spectroscopy (SORS) have emerged that allow detection from beneath diffusely scattering opaque materials, including biological media such as animal tissue. We have been able to demonstrate that the gold NP assemblies could be detected from within both proteinaceous and high lipid containing animal tissue by employing a SORS technique with a backscattered geometry.

  4. A Novel Polyacrylamide Magnetic Nanoparticle Contrast Agent for Molecular Imaging using MRI

    Bradford A. Moffat

    2003-10-01

    Full Text Available A novel Polyacrylamide superparamagnetic iron oxide nanoparticle platform is described which has been synthetically prepared such that multiple crystals of iron oxide are encapsulated within a single Polyacrylamide matrix (PolyAcrylamide Magnetic [PAM] nanoparticles. This formulation provides for an extremely large T2 and T2* relaxivity of between 620 and 1140 sec−1 mM−1. Administration of PAM nanoparticles into rats bearing orthotopic 9L gliomas allowed quantitative pharmacokinetic analysis of the uptake of nanoparticles in the vasculature, brain, and glioma. Addition of polyethylene glycol of varying sizes (0.6, 2, and 10 kDa to the surface of the PAM nanoparticles resulted in an increase in plasma half-life and affected tumor uptake and retention of the nanoparticles as quantified by changes in tissue contrast using MRI. The flexible formulation of these nanoparticles suggests that future modifications could be accomplished allowing for their use as a targeted molecular imaging contrast agent and/or therapeutic platform for multiple indications.

  5. Thallium Labeled Citrate-Coated Prussian Blue Nanoparticles as Potential Imaging Agent

    Krisztián Szigeti

    2018-01-01

    Full Text Available Background. The aim of this study was to develop and characterize a nanoparticle-based image-contrast platform which is biocompatible, chemically stable, and accessible for radiolabeling with 201Tl. We explored whether this nanoparticle enhanced the T1 signal which might make it an MRI contrast agent as well. Methods. The physical properties of citrate-coated Prussian blue nanoparticles (PBNPs (iron(II;iron(III;octadecacyanide doped with 201Tl isotope were characterized with atomic force microscopy, dynamic light scattering, and zeta potential measurement. PBNP biodistribution was determined by using SPECT and MRI following intravenous administration into C57BL6 mice. Activity concentrations (MBq/cm3 were calculated from the SPECT scans for each dedicated volume of interest (VOI of liver, kidneys, salivary glands, heart, lungs, and brain. Results. PBNP accumulation peaked at 2 hours after injection predominantly in the kidneys and the liver followed by a gradual decrease in activity in later time points. Conclusion. We synthetized, characterized, and radiolabeled a Prussian blue-based nanoparticle platform for contrast material applications. Its in vivo radiochemical stability and biodistribution open up the way for further diagnostic applications.

  6. Synthesis of 18F labeled clotrimazole derivatives as a potential PET imaging agent

    Jung, Soon Jae; Kim, In Jong; Park, Jeong Hoon; Lee, Heung Nae; Kim, Sang Wook; Hur, Min Goo; Choi, Sang Moo; Yang, Seung Dae; Yu, Kook Hyun

    2010-01-01

    Clotrimazole [1- -1H-imidazole, CLT] has been reported to inhibit the proliferation of vascular endothelial and act as an in vitro anti-VEGF drug. It is also shown to inhibit angiogenesis in an animal model. The radioisotope labeled clotrimazole derivative can be utilized to monitor the physiologic processes of cancer. In this study, we synthesized [ 18 F]fluoride labeled clotrimazole derivatives as a new tumor imaging agent for PET. The references were prepared by a refluxing with clotrimazole and an excess of fluoroalkyltosylate in acetonitrile for 36 h and clotrimazole reacted with ditosylalkane to give precursors. [ 18 ]Fluoride labeled reaction was performed with precursor in Kryptofix[2.2.2]/K 2 CO 3 for 10 min at 80 .deg. C. The radiolabeling mixture was passed through a silica Sep-Pak cartridge to remove 18 F - . The [ 18 ]F-clotrimazole derivatives were synthesized with a 20 ∼ 25% yield. In the radiofluoriantion step, we used acetonitrile and DMSO as a solvent and observed a higher at the acetonitrile (25%) reaction compared with the DMSO reaction (5%)

  7. An improved synthesis of 4-[18F]-ADAM, a potent serotonin transporter imaging agent

    Huang, Y.-Y.; Huang, W.-S.; Chu, T.-C.; Shiue, C.-Y.

    2009-01-01

    An improved synthesis of N,N-dimethyl-2-(2-amino-4-[ 18 F]fluorophenylthio)benzylamine (4-[ 18 F]-ADAM, 2) as a potent serotonin transporter (SERT) imaging agent is described. Molecular orbital (MO) calculation predicts that N,N-dimethyl-2- (2-nitro-4-trimethylammoniumtrifluoromethanesulfonylphenylthio)benzamide (8) is probably a better precursor than N,N-dimethyl-2-(2,4-dinitrophenylthio)benzylamine (1) for preparing 2. Radioligand 2 was synthesized by the reaction of either precursor 1 or precursor 8 with K[ 18 F]/K 2.2.2 at 120 deg. C followed by reduction with BH 3 at 80 deg. C. The radiochemical yield (EOB) of 2 synthesized from precursor 1 and 8 was 5.7±2.4% (n=6) and 14.8±4.0% (n=5), respectively, in a synthesis time of 120 min from EOB. The specific activity of 2 was 3 Ci/μmol or 111 GBq/μmol (EOB). Thus, this new synthetic method has significantly improved the radiochemical yield of 4-[ 18 F]-ADAM and makes this radioligand more accessible to PET Centers without a cyclotron.

  8. An improved synthesis of 4-[{sup 18}F]-ADAM, a potent serotonin transporter imaging agent

    Huang, Y.-Y. [PET Center, Department of Nuclear Medicine, Tri-Service General Hospital 325 Section 2, Cheng-Kung Road, Neihu 114, Taipei, Taiwan (China); Department of Biomedical Engineering and Environmental Sciences, National Thising Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China); Huang, W.-S. [PET Center, Department of Nuclear Medicine, Tri-Service General Hospital 325 Section 2, Cheng-Kung Road, Neihu 114, Taipei, Taiwan (China); Chu, T.-C. [Department of Biomedical Engineering and Environmental Sciences, National Thising Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China); Shiue, C.-Y. [PET Center, Department of Nuclear Medicine, Tri-Service General Hospital 325 Section 2, Cheng-Kung Road, Neihu 114, Taipei, Taiwan (China)], E-mail: shiue@ndmctsgh.edu.tw

    2009-06-15

    An improved synthesis of N,N-dimethyl-2-(2-amino-4-[{sup 18}F]fluorophenylthio)benzylamine (4-[{sup 18}F]-ADAM, 2) as a potent serotonin transporter (SERT) imaging agent is described. Molecular orbital (MO) calculation predicts that N,N-dimethyl-2- (2-nitro-4-trimethylammoniumtrifluoromethanesulfonylphenylthio)benzamide (8) is probably a better precursor than N,N-dimethyl-2-(2,4-dinitrophenylthio)benzylamine (1) for preparing 2. Radioligand 2 was synthesized by the reaction of either precursor 1 or precursor 8 with K[{sup 18}F]/K{sub 2.2.2} at 120 deg. C followed by reduction with BH{sub 3} at 80 deg. C. The radiochemical yield (EOB) of 2 synthesized from precursor 1 and 8 was 5.7{+-}2.4% (n=6) and 14.8{+-}4.0% (n=5), respectively, in a synthesis time of 120 min from EOB. The specific activity of 2 was 3 Ci/{mu}mol or 111 GBq/{mu}mol (EOB). Thus, this new synthetic method has significantly improved the radiochemical yield of 4-[{sup 18}F]-ADAM and makes this radioligand more accessible to PET Centers without a cyclotron.

  9. Technetium-99m p-iodophenethyldiaminodithiol (DADT-IPE): potential brain perfusion imaging agent for SPECT

    Shiba, K.; Mori, H.; Matsuda, H.; Hisada, K.

    1992-01-01

    A new ligand, an N-p-iodophenethyl diaminodithiol (DADT-IPE), an analog of N-isopropyl-p-iodoamphetamine (IMP), was synthesized and subsequently complexed with 99m Tc, using stannous chloride as a reducing agent. Two complexes (a and b) were separated from 99m Tc-DADT-IPE by high performance liquid chromatography (HPLC). Competitive inhibition studies showed that the IC 50 value of DADT-IPE (70 μM) was similar to that of IMP (49 μM). Biodistribution studies of one of the complexes [ 99m Tc-DADT-IPE(a)] in rats showed that 0.65% of the injected dose of the tracer remained in the brain at 5 min after intravenous injection, with 0.53% of the dose remaining in the brain at 60 min post-injection, whereas the corresponding values for the other complex [ 99m Tc-DADT-IPE(b)] were 0.34% dose in the brain at 5 min and 0.28% dose in the brain at 60 min post-injection. The half-life for clearance of 99m Tc-DADT-IPE(a) from rat brain was found to be more than 5h. These results suggested that 99m Tc-DADT-IPE(a) has characteristics which are suitable for cerebral perfusion imaging. (author)

  10. Contrast-enhanced CT with a High-Affinity Cationic Contrast Agent for Imaging ex Vivo Bovine, Intact ex Vivo Rabbit, and in Vivo Rabbit Cartilage

    Stewart, Rachel C.; Bansal, Prashant N.; Entezari, Vahid; Lusic, Hrvoje; Nazarian, Rosalynn M.; Snyder, Brian D.; Grinstaff, Mark W.

    2013-01-01

    The high affinity of a cationic iodinated contrast agent for cartilage provides better tissue visualization, easier segmentation, higher contrast-to-noise ratios, and longer usable imaging windows and requires a lower dose of injected contrast agent compared with an anionic contrast agent.

  11. Radionuclide study of the hepatobiliary system function in patients with diabetes mellitus

    Slavnov, V.M.; Savich, O.A.; Markov, V.V.

    2002-01-01

    The functional state of the liver parenchyma, concentration and motor functions of the gallbladder in patients with diabetes mellitus (DM) was studied. To analyze hepatobiliary system disorders depending on the type of DM, presence of complications, duration of the disease and the age of the patients

  12. Robotic resections in hepatobiliary oncology - initial experience with Xi da Vinci system in India.

    Chandarana, M; Patkar, S; Tamhankar, A; Garg, S; Bhandare, M; Goel, M

    2017-01-01

    Minimal invasive surgery has proven its advantages over open surgeries in the perioperative period. Food and Drug Administration approved da Vinci robot in 2000. The latest version, da Vinci Xi system has a mobile tower-based robot with several modifications to improve the functionality, versatility, and operative ease. None of the centers have reported exclusively on hepatobiliary oncology using the da Vinci Xi system. We report our initial experience. To study the feasibility, advantages, and discuss the operative technique of da Vinci Xi system in hepatobiliary oncology. Data were analyzed retrospectively from a prospectively maintained database from June 2015 to October 2016. Twenty-five patients with suspected or proven hepatobiliary malignancies were operated. Total robotic technique using da Vinci Xi system was used. Demographic details and perioperative outcomes were noted. Of the 25 surgeries, 14 patients had a suspected gallbladder malignancy, 11 patients had primary or metastatic liver tumor. Median age was 53 years. The average duration of surgery was 225 min with a median blood loss 150 ml. The median postoperative stay was 4 days. The median nodal yield for radical cholecystectomy was seven. Five patients required conversion. Two of these developed postoperative morbidity. Robotic surgery for hepatobiliary oncology is feasible and can be performed safely in experienced hands. Increasing experience in this field may equal or even prove advantageous over conventional or laparoscopic approach in future. A cautious approach with judicious patient selection is the key to establishing robotic surgery as a standard surgical approach.

  13. 99m Tc-DISIDA hepatobiliary scintigram in evaluation of clonorchis sinensis infestation in endemic region

    Yum, Ha Yong

    1985-01-01

    This study was performed to evaluate clinical utilization of 99 mTc-DISIDA scintigraphy in detection of Cs-infestation and its complication as well as combined disease in liver, in comparison with detection rate of Cs-stool ova and to describe unique pattern of hepatobiliary bile flow found on the study. (Author)

  14. Morbidity and mortality after liver resection for benign and malignant hepatobiliary lesions

    Erdogan, Deha; Busch, Olivier R. C.; Gouma, Dirk J.; van Gulik, Thomas M.

    2009-01-01

    Aim: Although most partial liver resections are performed for malignant lesions, an increasing contingent of benign lesions is also considered for surgery. The aim was to assess post-operative morbidity and mortality after liver resection for benign hepatobiliary lesions in comparison with outcome

  15. Experimental and clinical trials of new /sub 99m/Tc-labeled hepatobiliary agents

    Wistow, B.W.; Subramanian, G.; Gagne, G.M.; Henderson, R.W.; McAfee, J.G.; Hall, R.C.; Grossman, Z.D.

    1978-01-01

    Several new derivatives of lidocaine were synthesized and used to examine the intra- and extrahepatic bile ducts and gallbladder. Diisopropyl-IDA exhibited approximately twice the bile concentration of 131 I-rose bengal during the first hour after injection. P-butyl-IDA also concentrates moderately well in the bile and has the added advantage of very low excretion into the urine (2%). It seems more effective than the other IDA derivatives at high bilirubin levels

  16. Application of pharmacokinetic modeling to the radiation dosimetry of hepatobiliary agents

    Loberg, M.D.; Buddemeyer, E.U.

    1981-01-01

    Dosimetry calculations based on biodistribution data from lower animal species often inadequately approximate the true dosimetry in humans and seldom apply in the presence of human pathology. An alternative approach is to use animal data for the limited purpose of developing a pharmacokinetic model describing the various compartments and their interconnecting pathways. To the extent that components are similarly connected in man, the model can be used to compute cumulative concentrations (μCi-h/gm) in humans by using the compartment masses and rate constants appropriate for man. In this manner dose estimates can be obtained which are less dependent upon the species from which the model was derived. The altered radiation dose in certain disease states having a known relationship to the model can also be predicted with confidence. This work reports the development in dogs of a four-compartment model which accurately describes the in-vivo distribution of Tc/sup 99m/-HIDA. The pharmacokinetic model was used to predict the kinetics of the HIDA analog which would yield clinically useful information, while minimizing patient radiation exposure

  17. Technetium-99m dithiocarbamates: the development of a new hepatobiliary agent

    Baldas, J.; Pojer, P.M.

    1983-01-01

    Preparation of dithiocarbamato ligands, preparation of sup(99m)Tc-dithiocarbamato complexes and physical properties of these complexes are discussed. The in vivo distribution of the complexes in mice correlated with their polarity. The lipophilic complexes were rapidly extracted by the liver and were then either retained or were slowly excreted. The soluble, polar complexes were characterised by slow blood clearance which occurred concurrently with rapid liver excretion. The ethylenebis (dithiocarbamato) complex enabled gallbladder visualisation over a period greater than two and a half hours

  18. Three-dimensional imaging of the aortic vessel wall using an elastin-specific magnetic resonance contrast agent.

    Makowski, Marcus R; Preissel, Anne; von Bary, Christian; Warley, Alice; Schachoff, Sylvia; Keithan, Alexandra; Cesati, Richard R; Onthank, David C; Schwaiger, Markus; Robinson, Simon P; Botnar, René M

    2012-07-01

    The aim of this study was to demonstrate the feasibility of high-resolution 3-dimensional aortic vessel wall imaging using a novel elastin-specific magnetic resonance contrast agent (ESMA) in a large animal model. The thoracic aortic vessel wall of 6 Landrace pigs was imaged using a novel ESMA and a nonspecific control agent. On day 1, imaging was performed before and after the administration of a nonspecific control agent, gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA; Bayer Schering AG, Berlin, Germany). On day 3, identical scans were repeated before and after the administration of a novel ESMA (Lantheus Medical Imaging, North Billerica, Massachusetts). Three-dimensional inversion recovery gradient echo delayed-enhancement imaging and magnetic resonance (MR) angiography of the thoracic aortic vessel wall were performed on a 1.5-T MR scanner (Achieva; Philips Medical Systems, the Netherlands). The signal-to-noise ratio and the contrast-to-noise ratio of arterial wall enhancement, including the time course of enhancement, were assessed for ESMA and Gd-DTPA. After the completion of imaging sessions, histology, electron microscopy, and inductively coupled plasma mass spectroscopy were performed to localize and quantify the gadolinium bound to the arterial vessel wall. Administration of ESMA resulted in a strong enhancement of the aortic vessel wall on delayed-enhancement imaging, whereas no significant enhancement could be measured with Gd-DTPA. Ninety to 100 minutes after the administration of ESMA, significantly higher signal-to-noise ratio and contrast-to-noise ratio could be measured compared with the administration of Gd-DTPA (45.7 ± 9.6 vs 13.2 ± 3.5, P wall imaging using a novel ESMA in a large animal model under conditions resembling a clinical setting. Such an approach could be useful for the fast 3-dimensional assessment of the arterial vessel wall in the context of atherosclerosis, aortic aneurysms, and hypertension.

  19. Harmonic US imaging of vesicoureteric reflux in children: usefulness of a second generation US contrast agent.

    Ascenti, Giorgio; Zimbaro, Giovanni; Mazziotti, Silvio; Chimenz, Roberto; Fede, Carmelo; Visalli, Carmela; Scribano, Emanuele

    2004-06-01

    Contrast-enhanced voiding urosonography (VUS) is largely accepted both for the diagnosis and follow-up of vesicoureteric reflux (VUR) in children. To evaluate the usefulness of contrast-enhanced second-harmonic VUS in the diagnosis and grading of VUR, using a second-generation contrast agent. Eighty consecutive children were prospectively studied with contrast-enhanced second-harmonic VUS. All children received a second-generation contrast medium, constituted by phospholipid-stabilized microbubbles of sulphur-hexafluoride (SonoVue, Bracco, Milan, Italy). US monitoring of the bladder, of the retrovesical space and of the kidneys was performed using, alternatively, both tissue-harmonic and contrast-harmonic modes. In those young boys where VUR was depicted at VUS, examination was completed with transperineal, sagittal urethral exploration during micturition. VUR was graded in five steps and diagnoses were compared with voiding cystourethrography (VCUG). VUR was diagnosed in 52 reno-ureteral units with VUS. In 49 of these reno-ureteral units, VCUG confirmed the presence of VUR. In comparison to VUS, sensitivity and negative predictive value of VCUG were inferior. The grade of VUR detected at VUS was higher than that detected at VCUG in three units. In no case was the grade of VUR detected at VCUG higher than the one detected at VUS. The differences between VUS and VCUG in grading VUR were statistically significant (p=0.02). Imaging of the normal posterior urethra was skilfully demonstrated with US in 15 young boys with VUR. No statistically significant differences were found between tissue-harmonic and contrast-harmonic mode (p=0.102). Contrast-enhanced second-harmonic VUS is a sensitive and easy technique for the evaluation of VUR. A second-generation US contrast medium such as SonoVue, if available, should be the first choice as the dose required for one examination is much lower and consequently significant reduction of contrast agent cost is possible. Copyright

  20. {sup 18}F-Labelled metomidate analogues as adrenocortical imaging agents

    Erlandsson, Maria; Karimi, Farhad [Department of Biochemistry and Organic Chemistry, Uppsala University, Box 576, S-751 23 Uppsala (Sweden); Lindhe, Orjan [Uppsala Imanet, GE Healthcare, Box 967, S-751 09 Uppsala (Sweden); Langstroem, Bengt [Department of Biochemistry and Organic Chemistry, Uppsala University, Box 576, S-751 23 Uppsala (Sweden)], E-mail: bengt.langstrom@biorg.uu.se

    2009-05-15

    Introduction: Two- and one-step syntheses of {sup 18}F-labelled analogues of metomidate, such as 2-[{sup 18}F]fluoroethyl 1-[(1R)-1-phenylethyl]-1H-imidazole-5-carboxylate (1), 2-[{sup 18}F]fluoroethyl 1-[(1R)-1-(4-chlorophenyl)ethyl]-1H-imidazole-5-carboxylate (2), 2-[{sup 18}F]fluoroethyl 1-[(1R)-1-(4-bromophenyl)ethyl]-1H-imidazole-5-carboxylate (3), 3-[{sup 18}F]fluoropropyl 1-[(1R)-1-(4-bromophenyl)ethyl]-1H-imidazole-5-carboxylate (4) and 3-[{sup 18}F]fluoropropyl 1-[(1R)-1-phenylethyl]-1H-imidazole-5-carboxylate (5) are presented. Methods: Analogues 1-5 were prepared by a two-step reaction sequence that started with the synthesis of either 2-[{sup 18}F]fluoroethyl 4-methylbenzenesulfonate or 3-[{sup 18}F]fluoropropyl 4-methylbenzenesulfonate. These were used as {sup 18}F-alkylating agents in the second step, in which they reacted with the ammonium salt of a 1-[(1R)-1-phenylethyl]-1H-imidazole-5-carboxylic acid. One-step-labelling syntheses of 1, 2 and 5 were also explored. Analogues 1-4 were biologically validated by frozen-section autoradiography and organ distribution. Metabolite analysis was performed for 2 and 3. Results: The radiochemical yield of the two-step synthesis was in the range of 10-29% and that of the one-step synthesis was 25-37%. Using microwave irradiation in the one-step synthesis of 1 and 2 increased the radiochemical yield to 46{+-}3% and 79{+-}30%, respectively. Conclusion: Both the frozen-section autoradiography and organ distribution results indicated that analogue 2 has a potential as an adrenocortical imaging agent, having the highest degree of specific adrenal binding and best ratio of adrenal to organ uptake among the compounds studied.

  1. Magnetic field perturbation in proton MR imaging - A study of a contrast agent and of distortions due to metallic implants

    Olsson, M.

    1992-01-01

    Perturbations of the static magnetic field in proton MR imaging (NMR imaging, MRI, MRT) result in image distortion and/or signal loss. An investigation of a superparamagnetic contrast agent for MR imaging has been performed. Magnetite particles were embedded in biodegradable starch spheres with a diameter of one micrometer. Animal experiments showed that the agent was quickly accumulated in the reticulo-endothelial system (RES), causing a decrease in signal intensity in this region. Diffusion within the locally generated magnetic field perturbation is responsible for signal loss in spin-echo images. Furthermore, the magnetic properties of various aneurysm clips were investigated to determine which clips could be used safely in a clinical MR investigation. MR artifacts caused by the metallic clips were studied using a geometric phantom. Non-ferromagnetic clips were concluded to be safe for examinations with medium field (0.3 tesla) MR imaging systems. A comparison study between MR and CT was performed on patients harbouring intracranial, nonferromagnetic aneurysm clips. The artifacts close to the clips were equally serve for MR and CT, but at some distance, the MR images were much less affected than the CT images. Finally, a computer program capable of simulating any realistic MR imaging situation has been developed. Raw data matrices are obtained by solving the Bloch equations. Corrections for intravascular spin behaviour have been implemented together with efficient algorithms. A quantitative investigation of signal displacement and signal loss, caused by small metallic implants, has been performed by computer simulation. An exact expression for the magnetic field outside a homogeneous ellipsoid in an external magnetic field has been derived. Distortions in MR images, caused by perturbing ellipsoids of different shapes and orientations, were studied. (30 refs.) (au)

  2. Transport mechanisms of hepatic uptake and bile excretion in clinical hepatobiliary scintigraphy with 99mTc-N-pyridoxyl-5-methyltryptophan

    Kobayashi, Masato; Nakanishi, Takeo; Nishi, Kodai; Higaki, Yusuke; Okudaira, Hiroyuki; Ono, Masahiro; Tsujiuchi, Takafumi; Mizutani, Asuka; Nishii, Ryuichi; Tamai, Ikumi; Arano, Yasushi; Kawai, Keiichi

    2014-01-01

    Introduction: In clinical hepatobiliary scintigraphy, 99m Tc-N-pyridoxyl-5-methyltryptophan ( 99m Tc-PMT) is an effective radiotracer among the 99m Tc-pyridoxylaminates. However, the mechanisms of human hepatic uptake and bile excretion transport of 99m Tc-PMT have not been determined. We thus investigated the transport mechanisms of human hepatic uptake and bile excretion in hepatobiliary scintigraphy with 99m Tc-PMT. Methods: Four solute carrier (SLC) transporters involved in hepatic uptake were evaluated using human embryonic kidney (HEK) and HeLa cells with high expression of SLC transporters (organic anion transporting polypeptide (OATP)1B1, OATP1B3, OATP2B1, organic anion transporters (OAT)2 and organic cation transporters (OCT)1) after 5 min of 99m Tc-PMT incubation. Metabolic analysis of 99m Tc-PMT was performed using pooled human liver S9. Adenosine triphosphate (ATP)-binding cassette (ABC) transporters for bile excretion were examined using hepatic ABC transporter vesicles human expressing multiple drug resistance 1 (MDR1), multidrug resistance-associated protein 2 (MRP2), breast cancer resistance protein or bile salt export pump. 99m Tc-PMT was incubated for 1, 3 and 5 min with ATP or adenosine monophosphate and these vesicles. SPECT scans were performed in normal and Eisai hyperbilirubinemic (EHBR) model rats, deficient in Mrp2 transporters, without and with verapamil (rat Mdr1 and human MDR1 inhibitor) after intravenous injection of 99m Tc-PMT. Results: Uptake of 99m Tc-PMT in HEK293/OATP1B1 and HeLa/OATP1B3 was significantly higher than that in HEK293- and HeLa-mock cells. 99m Tc-PMT was not metabolized in the human liver S9. In vesicles with high expression of ABC transporters, uptake of MDR1 or MRP2 was significantly higher at all incubation times. Bile excretion of 99m Tc-PMT was also identified by comparison between normal and EHBR rats with and without verapamil on in-vivo imaging. Conclusions: Human hepatic uptake of 99m Tc-PMT was transferred

  3. Evaluating Hepatobiliary Transport with 18F-Labeled Bile Acids: The Effect of Radiolabel Position and Bile Acid Structure on Radiosynthesis and In Vitro and In Vivo Performance

    Stef De Lombaerde

    2018-01-01

    Full Text Available Introduction. An in vivo determination of bile acid hepatobiliary transport efficiency can be of use in liver disease and preclinical drug development. Given the increased interest in bile acid Positron Emission Tomography- (PET- imaging, a further understanding of the impact of 18-fluorine substitution on bile acid handling in vitro and in vivo can be of significance. Methods. A number of bile acid analogues were conceived for nucleophilic substitution with [18F]fluoride: cholic acid analogues of which the 3-, 7-, or 12-OH function is substituted with a fluorine atom (3α-[18F]FCA; 7β-[18F]FCA; 12β-[18F]FCA; a glycocholic and chenodeoxycholic acid analogue, substituted on the 3-position (3β-[18F]FGCA and 3β-[18F]FCDCA, resp.. Uptake by the bile acid transporters NTCP and OATP1B1 was evaluated with competition assays in transfected CHO and HEK cell lines and efflux by BSEP in membrane vesicles. PET-scans with the tracers were performed in wild-type mice (n=3 per group: hepatobiliary transport was monitored and compared to a reference tracer, namely, 3β-[18F]FCA. Results. Compounds 3α-[18F]FCA, 3β-[18F]FGCA, and 3β-[18F]FCDCA were synthesized in moderate radiochemical yields (4–10% n.d.c. and high radiochemical purity (>99%; 7β-[18F]FCA and 12β-[18F]FCA could not be synthesized and included further in this study. In vitro evaluation showed that 3α-FCA, 3β-FGCA, and 3β-FCDCA all had a low micromolar Ki-value for NTCP, OATP1B1, and BSEP. In vivo, 3α-[18F]FCA, 3β-[18F]FGCA, and 3β-[18F]FCDCA displayed hepatobiliary transport with varying efficiency. A slight yet significant difference in uptake and efflux rate was noticed between the 3α-[18F]FCA and 3β-[18F]FCA epimers. Conjugation of 3β-[18F]FCA with glycine had no significant effect in vivo. Compound 3β-[18F]FCDCA showed a significantly slower hepatic uptake and efflux towards gallbladder and intestines. Conclusion. A set of 18F labeled bile acids was synthesized that are

  4. Line-scanning confocal microscopy for high-resolution imaging of upconverting rare-earth-based contrast agents

    Higgins, Laura M.; Zevon, Margot; Ganapathy, Vidya; Sheng, Yang; Tan, Mei Chee; Riman, Richard E.; Roth, Charles M.; Moghe, Prabhas V.; Pierce, Mark C.

    2015-01-01

    Abstract. Rare-earth (RE) doped nanocomposites emit visible luminescence when illuminated with continuous wave near-infrared light, making them appealing candidates for use as contrast agents in biomedical imaging. However, the emission lifetime of these materials is much longer than the pixel dwell times used in scanning intravital microscopy. To overcome this limitation, we have developed a line-scanning confocal microscope for high-resolution, optically sectioned imaging of samples labeled with RE-based nanomaterials. Instrument performance is quantified using calibrated test objects. NaYF4:Er,Yb nanocomposites are imaged in vitro, and in ex vivo tissue specimens, with direct comparison to point-scanning confocal microscopy. We demonstrate that the extended pixel dwell time of line-scanning confocal microscopy enables subcellular-level imaging of these nanomaterials while maintaining optical sectioning. The line-scanning approach thus enables microscopic imaging of this emerging class of contrast agents for preclinical studies, with the potential to be adapted for real-time in vivo imaging in the clinic. PMID:26603495

  5. Synthesis and biological evaluation of [18F]tetrafluoroborate: a PET imaging agent for thyroid disease and reporter gene imaging of the sodium/iodide symporter

    Jauregui-Osoro, Maite; Sunassee, Kavitha; Weeks, Amanda J.; Berry, David J.; Paul, Rowena L.; Cleij, Marcel; O'Doherty, Michael J.; Marsden, Paul K.; Szanda, Istvan; Blower, Philip J.; Banga, Jasvinder Paul; Clarke, Susan E.M.; Ballinger, James R.; Cheng, Sheue-Yann

    2010-01-01

    The human sodium/iodide symporter (hNIS) is a well-established target in thyroid disease and reporter gene imaging using gamma emitters 123 I-iodide, 131 I-iodide and 99m Tc-pertechnetate. However, no PET imaging agent is routinely available. The aim of this study was to prepare and evaluate 18 F-labelled tetrafluoroborate ([ 18 F]TFB) for PET imaging of hNIS. [ 18 F]TFB was prepared by isotopic exchange of BF 4 - with [ 18 F]fluoride in hot hydrochloric acid and purified using an alumina column. Its identity, purity and stability in serum were determined by HPLC, thin-layer chromatography (TLC) and mass spectrometry. Its interaction with NIS was assessed in vitro using FRTL-5 rat thyroid cells, with and without stimulation by thyroid-stimulating hormone (TSH), in the presence and absence of perchlorate. Biodistribution and PET imaging studies were performed using BALB/c mice, with and without perchlorate inhibition. [ 18 F]TFB was readily prepared with specific activity of 10 GBq/mg. It showed rapid accumulation in FRTL-5 cells that was stimulated by TSH and inhibited by perchlorate, and rapid specific accumulation in vivo in thyroid (SUV = 72 after 1 h) and stomach that was inhibited 95% by perchlorate. [ 18 F]TFB is an easily prepared PET imaging agent for rodent NIS and should be evaluated for hNIS PET imaging in humans. (orig.)

  6. A kit prepared technetium-99m agent for cardiac imaging: a preliminary evaluation in dogs

    Thakur, M.L.

    1982-01-01

    A new 99mTc cardiac agent that can be prepared by a kit method has been developed. The preliminary results in animals indicate that the agent is distributed in the myocardium according to the regional myocardial blood flow and has ability to delineate a myocardial region of infarction

  7. Searching for an alternative oral contrast agent for GI tract MR imaging; in vitro phase, initial report

    Okla, W.; Szeszkowski, W.; Cieszanowski, A.; Golebiowski, M.

    2002-01-01

    MR has been recently considered to be suitable method for detection GI tract pathologies. A few substances (some of a natural origin) seem to act as an efficient oral MR contrast agents. The aim of this study is to find an alternative substance, which can be administrated orally to patients in order to enhance signal intensity (SI). The ideal agent should have a biphase pattern (high SI in T1 and low in T2), and should be nontoxic and cost effective. Phantom experiments were conducted with 1.5 T MR scanner. T1W and T2W sequences were used for initial estimation. Number of different agents such as: water, Gd-DTPA, barium sulfate, green tea, blueberry juice, cranberry juice, blackcurrant juice, and some more were evaluated. Signal intensity was measured by using elliptical region of interest (ROI). MR imaging in one patient with stomach cancer was also performed. In T1W-FFE sequence cranberry juice reached satisfactorily high signal (SI=1760.14). In T2W-TSE sequence this substance reduced signal intensity (SI=23.10) almost to background level. Blueberry juice appear to be the next substance capable to generate high signal (SI=1558.31) in T1W sequence (T1-TSE). MR examination of a patient with stomach adenocarcinoma (using blueberry juice as an oral contrast agent) satisfactorily depicted and delineated tumor mass on both: T1W and T2W images. Cranberry juice and blueberry juice seemed to act effectively as oral contrast agents for gastrointestinal MR imaging. Thus they need further exploration and trials. (author)

  8. Dual-purpose linker for alpha helix stabilization and imaging agent conjugation to glucagon-like peptide-1 receptor ligands.

    Zhang, Liang; Navaratna, Tejas; Liao, Jianshan; Thurber, Greg M

    2015-02-18

    Peptides display many characteristics of efficient imaging agents such as rapid targeting, fast background clearance, and low non-specific cellular uptake. However, poor stability, low affinity, and loss of binding after labeling often preclude their use in vivo. Using glucagon-like peptide-1 receptor (GLP-1R) ligands exendin and GLP-1 as a model system, we designed a novel α-helix-stabilizing linker to simultaneously address these limitations. The stabilized and labeled peptides showed an increase in helicity, improved protease resistance, negligible loss or an improvement in binding affinity, and excellent in vivo targeting. The ease of incorporating azidohomoalanine in peptides and efficient reaction with the dialkyne linker enable this technique to potentially be used as a general method for labeling α helices. This strategy should be useful for imaging beta cells in diabetes research and in developing and testing other peptide targeting agents.

  9. Primary evaluation of a nickel-chlorophyll derivative as a multimodality agent for tumor imaging and photodynamic therapy

    Ozge Er; Fatma Yurt Lambrecht; Kasim Ocakoglu; Cagla Kayabasi; Cumhur Gunduz

    2015-01-01

    In this study, the biological potential of a nickel chlorophyll derivative (Ni-PH-A) as a multimodal agent for tumor imaging and photodynamic therapy (PDT) was investigated. Optimum conditions of labeling with 131 I were investigated and determined as pH 10 and 1 mg amount of iodogen. Biodistribution results of 131 I labeled Ni-PH-A in female rats indicated that radiolabeled Ni-PH-A maximum uptake in the liver, spleen and ovary was observed at 30 min. Intercellular uptake and PDT efficacy of Ni-PH-A were better in MDAH-2774 (human ovarian endometrioid adenocarcinoma) than in MCF-7 (human breast adenocarcinoma) cells. Ni-PH-A might be a promising multimodal agent for lung, ovary and liver tumor imaging and PDT. (author)

  10. The Impact of “Omic” and Imaging Technologies on Assessing the Host Immune Response to Biodefence Agents

    Julia A. Tree

    2014-01-01

    Full Text Available Understanding the interactions between host and pathogen is important for the development and assessment of medical countermeasures to infectious agents, including potential biodefence pathogens such as Bacillus anthracis, Ebola virus, and Francisella tularensis. This review focuses on technological advances which allow this interaction to be studied in much greater detail. Namely, the use of “omic” technologies (next generation sequencing, DNA, and protein microarrays for dissecting the underlying host response to infection at the molecular level; optical imaging techniques (flow cytometry and fluorescence microscopy for assessing cellular responses to infection; and biophotonic imaging for visualising the infectious disease process. All of these technologies hold great promise for important breakthroughs in the rational development of vaccines and therapeutics for biodefence agents.

  11. Highly stable polymer coated nano-clustered silver plates: a multimodal optical contrast agent for biomedical imaging

    Ray, Aniruddha; Mukundan, Ananya; Karamchand, Leshern; Kopelman, Raoul; Xie, Zhixing; Wang, Xueding

    2014-01-01

    Here, we present a new optical contrast agent based on silver nanoplate clusters embedded inside of a polymer nano matrix. Unlike nanosphere clusters, which have been well studied, nanoplate clusters have unique properties due to the different possible orientations of interaction between the individual plates, resulting in a significant broadening of the absorption spectra. These nanoclusters were immobilized inside of a polymer cladding so as to maintain their stability and optical properties under in vivo conditions. The polymer-coated silver nanoplate clusters show a lower toxicity compared to the uncoated nanoparticles. At high nanoparticle concentrations, cell death occurs mostly due to apoptosis. These nanoparticles were used for targeted fluorescence imaging in a rat glioma cell line by incorporating a fluorescent dye into the matrix, followed by conjugation of a tumor targeting an F3 peptide. We further used these nanoparticles as photoacoustic contrast agents in vivo to enhance the contrast of the vasculature structures in a rat ear model. We observed a contrast enhancement of over 90% following the nanoparticle injection. It is also shown that these NPs can serve as efficient contrast agents, with specific targeting abilities for broadband multimodal imaging that are usable for diagnostic applications and that extend into use as therapeutic agents as well. (paper)

  12. Mechanical and dynamic characteristics of encapsulated microbubbles coupled by magnetic nanoparticles as multifunctional imaging and drug delivery agents

    Guo, Gepu; Lu, Lu; Yin, Leilei; Tu, Juan; Guo, Xiasheng; Wu, Junru; Xu, Di; Zhang, Dong

    2014-11-01

    Development of magnetic encapsulated microbubble agents that can integrate multiple diagnostic and therapeutic functions is a key focus in both biomedical engineering and nanotechnology and one which will have far-reaching impact on medical diagnosis and therapies. However, properly designing multifunctional agents that can satisfy particular diagnostic/therapeutic requirements has been recognized as rather challenging, because there is a lack of comprehensive understanding of how the integration of magnetic nanoparticles to microbubble encapsulating shells affects their mechanical properties and dynamic performance in ultrasound imaging and drug delivery. Here, a multifunctional imaging contrast and in-situ gene/drug delivery agent was synthesized by coupling super paramagnetic iron oxide nanoparticles (SPIOs) into albumin-shelled microbubbles. Systematical studies were performed to investigate the SPIO-concentration-dependence of microbubble mechanical properties, acoustic scattering response, inertial cavitation activity and ultrasound-facilitated gene transfection effect. These demonstrated that, with the increasing SPIO concentration, the microbubble mean diameter and shell stiffness increased and ultrasound scattering response and inertial cavitation activity could be significantly enhanced. However, an optimized ultrasound-facilitated vascular endothelial growth factor transfection outcome would be achieved by adopting magnetic albumin-shelled microbubbles with an appropriate SPIO concentration of 114.7 µg ml-1. The current results would provide helpful guidance for future development of multifunctional agents and further optimization of their diagnostic/therapeutic performance in clinic.

  13. Mechanical and dynamic characteristics of encapsulated microbubbles coupled by magnetic nanoparticles as multifunctional imaging and drug delivery agents

    Guo, Gepu; Lu, Lu; Tu, Juan; Guo, Xiasheng; Zhang, Dong; Yin, Leilei; Wu, Junru; Xu, Di

    2014-01-01

    Development of magnetic encapsulated microbubble agents that can integrate multiple diagnostic and therapeutic functions is a key focus in both biomedical engineering and nanotechnology and one which will have far-reaching impact on medical diagnosis and therapies. However, properly designing multifunctional agents that can satisfy particular diagnostic/therapeutic requirements has been recognized as rather challenging, because there is a lack of comprehensive understanding of how the integration of magnetic nanoparticles to microbubble encapsulating shells affects their mechanical properties and dynamic performance in ultrasound imaging and drug delivery. Here, a multifunctional imaging contrast and in-situ gene/drug delivery agent was synthesized by coupling super paramagnetic iron oxide nanoparticles (SPIOs) into albumin-shelled microbubbles. Systematical studies were performed to investigate the SPIO-concentration-dependence of microbubble mechanical properties, acoustic scattering response, inertial cavitation activity and ultrasound-facilitated gene transfection effect. These demonstrated that, with the increasing SPIO concentration, the microbubble mean diameter and shell stiffness increased and ultrasound scattering response and inertial cavitation activity could be significantly enhanced. However, an optimized ultrasound-facilitated vascular endothelial growth factor transfection outcome would be achieved by adopting magnetic albumin-shelled microbubbles with an appropriate SPIO concentration of 114.7 µg ml −1 . The current results would provide helpful guidance for future development of multifunctional agents and further optimization of their diagnostic/therapeutic performance in clinic. (paper)

  14. Utility decay rates of T1-weighted magnetic resonance imaging contrast based on redox-sensitive paramagnetic nitroxyl contrast agents

    Matsumoto, Ken-ichiro

    2009-01-01

    The availability and applicability of the combination of paramagnetic nitroxyl contrast agent and T 1 -weighted gradient echo (GE)-based dynamic magnetic resonance imaging (MRI) measurement for redox imaging are described. The time courses of T 1 -weighted GE MRI signal intensities according to first-order paramagnetic loss of a nitroxyl contrast agent were simulated for several experimental conditions. The apparent decay rate calculated based on decreasing T 1 -weighted MRI contrast (k MRI ) can show an approximate value of the original decay rate (k true ) discretionarily given for simulation with suitable experimental parameters. The difference between k MRI and k true can be sufficiently small under T 1 -weighted spoiled gradient echo (SPGR) scan conditions (repetition time=75 ms, echo time=3 ms, and flip angle=45deg), with a conventional redox-sensitive nitroxyl contrast agent, such as 4-hydroxy-2,2,6,6,-tetramethylpiperidine-N-oxyl (TEMPOL) and/or 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (carbamoyl-PROXYL), and with intravenous (i.v.) doses of below 1.5 γmol/g body weight (b.w.) for mice. The results of this simulation suggest that the k MRI of nitroxyl contrast agents can be the primary index of redox status under biological conditions. (author)

  15. Low-Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    2017-10-01

    low- cost and high-throughput was a key element proposed for this project, which we believe will be of significant benefit to the patients suffering...Award Number: W81XWH-15-1-0272 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the author(s

  16. Low Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    2017-10-01

    greater gas polarizations and production amounts/ throughputs- benefiting in particular from the advent of com- pact, high-power, relatively low- cost ...Award Number: W81XWH-15-1-0271 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...DISTRIBUTION STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the

  17. Development of Gd(III) porphyrin-conjugated chitosan nanoparticles as contrast agents for magnetic resonance imaging

    Jahanbin, Tania [Université Paul Sabatier, Toulouse III, INSERM U825, CHU Purpan, 31059 Toulouse Cedex 9 (France); Sauriat-Dorizon, Hélène [Institut de Chimie Moléculaire et des Matériaux d' Orsay, UMR CNRS 8182, ECBB, Université Paris-Sud, 91405 Orsay (France); Spearman, Peter [Faculty of Science, Engineering and Computing, University of Kingston, Penrhyn Road Kingston upon Thames Surrey KT1 2EE, London (United Kingdom); Benderbous, Soraya, E-mail: soraya.benderbous@univ-tlse3.fr [Université Paul Sabatier, Toulouse III, INSERM U825, CHU Purpan, 31059 Toulouse Cedex 9 (France); Korri-Youssoufi, Hafsa, E-mail: hafsa.korri-youssoufi@u-psud.fr [Institut de Chimie Moléculaire et des Matériaux d' Orsay, UMR CNRS 8182, ECBB, Université Paris-Sud, 91405 Orsay (France)

    2015-07-01

    A novel magnetic resonance imaging (MRI) contrast agent based on gadolinium meso-tetrakis(4-pyridyl)porphyrin [Gd(TPyP)] conjugated with chitosan nanoparticles has been developed. The chitosan nanoparticles were synthesized following an ionic gelation method and the conditions optimized to generate small nanoparticles (CNs) with a narrow size distribution of 35–65 nm. The gadolinium meso-tetrakis(4-pyridyl)porphyrin [Gd(TPyP)] was loaded into chitosan nanoparticles by passive adsorption. The interaction of chitosan with Gd(TPyP) has been examined by UV–visible, Fourier transform infrared spectroscopies (FT-IR) and inductively coupled plasma mass spectrometry (ICP-MS), which indicate the successful association of Gd(TPyP) without any structural distortion throughout the chitosan nanoparticles. The potential of Gd(TPyP)-CNs as MRI contrast agent has been investigated by magnetic resonance imaging (MRI) in-vitro. Relaxivities of Gd(TPyP)-CNs obtained from T{sub 1}-weighted images, increased with Gd concentration and attained an optimum r{sub 1} of 38.35 mM{sup −1} s{sup −1}, which is 12-fold higher compared to commercial Gd-DOTA (~ 4 mM{sup −1} s{sup −1} at 3T). The combination of such strong MRI contrast with the known properties of porphyrins in photodynamic therapy and biocompatibility of chitosan, presents a new perspective in using these compounds in cancer theranostics. - Highlights: • Synthesis of chitosan nanoparticles with small size • Study of loading properties with gadolinium porphyrins • In vitro properties of the conjugated complex as contrast agent for MRI imaging • Comparison of MRI properties with commercial contrast agent Gd-DOTA.

  18. Imaging of vaporised sub-micron phase change contrast agents with high frame rate ultrasound and optics

    Lin, Shengtao; Zhang, Ge; Jamburidze, Akaki; Chee, Melisse; Hau Leow, Chee; Garbin, Valeria; Tang, Meng-Xing

    2018-03-01

    Phase-change ultrasound contrast agent (PCCA), or nanodroplet, shows promise as an alternative to the conventional microbubble agent over a wide range of diagnostic applications. Meanwhile, high-frame-rate (HFR) ultrasound imaging with microbubbles enables unprecedented temporal resolution compared to traditional contrast-enhanced ultrasound imaging. The combination of HFR ultrasound imaging and PCCAs can offer the opportunity to observe and better understand PCCA behaviour after vaporisation captures the fast phenomenon at a high temporal resolution. In this study, we utilised HFR ultrasound at frame rates in the kilohertz range (5-20 kHz) to image native and size-selected PCCA populations immediately after vaporisation in vitro within clinical acoustic parameters. The size-selected PCCAs through filtration are shown to preserve a sub-micron-sized (mean diameter  1 µm) that originate from native PCCA emulsion. The results demonstrate imaging signals with different amplitudes and temporal features compared to that of microbubbles. Compared with the microbubbles, both the B-mode and pulse-inversion (PI) signals from the vaporised PCCA populations were reduced significantly in the first tens of milliseconds, while only the B-mode signals from the PCCAs were recovered during the next 400 ms, suggesting significant changes to the size distribution of the PCCAs after vaporisation. It is also shown that such recovery in signal over time is not evident when using size-selective PCCAs. Furthermore, it was found that signals from the vaporised PCCA populations are affected by the amplitude and frame rate of the HFR ultrasound imaging. Using high-speed optical camera observation (30 kHz), we observed a change in particle size in the vaporised PCCA populations exposed to the HFR ultrasound imaging pulses. These findings can further the understanding of PCCA behaviour under HFR ultrasound imaging.

  19. Augmented reality technology for preoperative planning and intraoperative navigation during hepatobiliary surgery: A review of current methods.

    Tang, Rui; Ma, Long-Fei; Rong, Zhi-Xia; Li, Mo-Dan; Zeng, Jian-Ping; Wang, Xue-Dong; Liao, Hong-En; Dong, Jia-Hong

    2018-04-01

    Augmented reality (AR) technology is used to reconstruct three-dimensional (3D) images of hepatic and biliary structures from computed tomography and magnetic resonance imaging data, and to superimpose the virtual images onto a view of the surgical field. In liver surgery, these superimposed virtual images help the surgeon to visualize intrahepatic structures and therefore, to operate precisely and to improve clinical outcomes. The keywords "augmented reality", "liver", "laparoscopic" and "hepatectomy" were used for searching publications in the PubMed database. The primary source of literatures was from peer-reviewed journals up to December 2016. Additional articles were identified by manual search of references found in the key articles. In general, AR technology mainly includes 3D reconstruction, display, registration as well as tracking techniques and has recently been adopted gradually for liver surgeries including laparoscopy and laparotomy with video-based AR assisted laparoscopic resection as the main technical application. By applying AR technology, blood vessels and tumor structures in the liver can be displayed during surgery, which permits precise navigation during complex surgical procedures. Liver transformation and registration errors during surgery were the main factors that limit the application of AR technology. With recent advances, AR technologies have the potential to improve hepatobiliary surgical procedures. However, additional clinical studies will be required to evaluate AR as a tool for reducing postoperative morbidity and mortality and for the improvement of long-term clinical outcomes. Future research is needed in the fusion of multiple imaging modalities, improving biomechanical liver modeling, and enhancing image data processing and tracking technologies to increase the accuracy of current AR methods. Copyright © 2018 First Affiliated Hospital, Zhejiang University School of Medicine in China. Published by Elsevier B.V. All rights

  20. Indocyanine green labeled with /sup 123/I for dynamic studies of the hepato-biliary system. [/sup 131/I, /sup 125/I

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub /sup 1///sub 2// = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of /sup 123/I-ICG (in dogs) will be compared to /sup 131/I-rose bengal and bromosulphalein labeled with iodine-125.

  1. STTARR: a radiation treatment and multi-modal imaging facility for fast tracking novel agent development in small animal models

    Yeung, Ivan; McKee, Trevor; Jaffray, David; Hill, Richard

    2014-01-01

    Small animal models play a pivotal role in the pipeline development of novel agents and strategies in personalized cancer therapy. The Spatio-Temporal Targeting and Amplification of Radiation Response Program (STTARR) consists of an animal imaging and precision radiation facility designed to provide innovative biologic imaging and targeted radiation treatment strategies in small animals. The design is to mirror the imaging and radiation treatment facility in a modern cancer center. The STTARR features imaging equipment of small animal scale including CT, MRI, PET, SPECT, Optical devices as well as image guided irradiators. The fleet of imaging and irradiation equipment provides a platform for identification of biological targets of the specific molecular pathways that influence both tumor progression and a patient's response to radiation therapy. Examples will be given in the utilization of the imaging facilities for development in novel approaches in cancer therapy including a PET-FAZA study for hypoxia measurement in a pancreatic adenocarcinoma xenograft model. In addition, the cone-beam image guided small animal irradiator developed at our institute will also be described. The animal platform (couch) provides motion in 3 dimensions to position the animal to the isocentre of the beam. A pair of rotational arms supporting the X-ray/detector pair enables acquisition of cone-beam images of the animal which give rise to image guided precision of 0.5 mm. The irradiation energy ranges from 50 to 225 kVp at a dose rate from 10-400 cGy/min. The gantry is able to direct X-ray beam of different directions to give conformal radiation treatment to the animal. A dedicated treatment planning system is able to perform treatment planning and provide commonly used clinical metrics in the animal treatment plan. Examples will be given to highlight the use of the image guided irradiator for research of drug/irradiation regimen in animal models. (author)

  2. PLGA nanoparticles from nano-emulsion templating as imaging agents: Versatile technology to obtain nanoparticles loaded with fluorescent dyes.

    Fornaguera, C; Feiner-Gracia, N; Calderó, G; García-Celma, M J; Solans, C

    2016-11-01

    The interest in polymeric nanoparticles as imaging systems for biomedical applications has increased notably in the last decades. In this work, PLGA nanoparticles, prepared from nano-emulsion templating, have been used to prepare novel fluorescent imaging agents. Two model fluorescent dyes were chosen and dissolved in the oil phase of the nano-emulsions together with PLGA. Nano-emulsions were prepared by the phase inversion composition (PIC) low-energy method. Fluorescent dye-loaded nanoparticles were obtained by solvent evaporation of nano-emulsion templates. PLGA nanoparticles loaded with the fluorescent dyes showed hydrodynamic radii lower than 40nm; markedly lower than those reported in previous studies. The small nanoparticle size was attributed to the nano-emulsification strategy used. PLGA nanoparticles showed negative surface charge and enough stability to be used for biomedical imaging purposes. Encapsulation efficiencies were higher than 99%, which was also attributed to the nano-emulsification approach as well as to the low solubility of the dyes in the aqueous component. Release kinetics of both fluorescent dyes from the nanoparticle dispersions was pH-independent and sustained. These results indicate that the dyes could remain encapsulated enough time to reach any organ and that the decrease of the pH produced during cell internalization by the endocytic route would not affect their release. Therefore, it can be assumed that these nanoparticles are appropriate as systemic imaging agents. In addition, in vitro toxicity tests showed that nanoparticles are non-cytotoxic. Consequently, it can be concluded that the preparation of PLGA nanoparticles from nano-emulsion templating represents a very versatile technology that enables obtaining biocompatible, biodegradable and safe imaging agents suitable for biomedical purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Approach to biliary imaging amongst consultant and specialist registrars in gastroenterology in a national setting.

    Murray, T

    2010-12-01

    Radiological investigation plays an important role in the management of conditions affecting the hepatobiliary system. However, multiple imaging modalities exist and inappropriate requesting can lead to delays in diagnosis and subsequent treatment.

  4. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    Josephson, Lee

    2004-01-01

    The goal of the current research is the development of a magnetic nanoparticle based MR contrast agent that binds the gastrin releasing peptide receptor, a molecular marker associated with neoplasia...

  5. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    Josephson, Lee

    2005-01-01

    An MR contrast agent targeted to the GRP receptor will be a novel pharmaceutical capable of non-invasively, and at high spatial resolution, characterizing healthy and patholological regions within the prostate...

  6. Biologically inspired autonomous agent navigation using an integrated polarization analyzing CMOS image sensor

    Sarkaer, M.; San Segundo Bello, D.; Van Hoof, C.; Theuwissen, A.

    2010-01-01

    The navigational strategies of insects using skylight polarization are interesting for applications in autonomous agent navigation because they rely on very little information for navigation. A polarization navigation sensor using the Stokes parameters to determine the orientation is presented. The

  7. Fabrication and imaging study of ultrasound/fluorescence bi-modal contrast agent based on polymeric microbubbles

    Xing Zhanwen; Ke Hengte; Wang Jinrui; Zhao Bo; Qu Enze; Yue Xiuli; Dai Zhifei

    2013-01-01

    Objective: To fabricate an ultrasound/fluorescence bi-modal contrast agent by enca