WorldWideScience

Sample records for hepatic blood perfusion

  1. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  2. CT perfusion of the liver during selective hepatic arteriography. Pure arterial blood perfusion of liver tumor and parenchyma

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Kojima, Hiroyuki; Kariya, Shuji; Sawada, Satoshi

    2003-01-01

    The purpose of this study was to quantify pure arterial blood perfusion of liver tumor and parenchyma by using CT perfusion during selective hepatic arteriography. A total of 44 patients underwent liver CT perfusion study by injection of contrast medium via the hepatic artery. CT-perfusion parameters including arterial blood flow, arterial blood volume, and arterial mean transit time in the liver parenchyma and liver tumor were calculated using the deconvolution method. The CT-perfusion parameters and vascularity of the tumor were compared. A complete analysis could be performed in 36 of the 44 patients. For liver tumor and liver parenchyma, respectively, arterial blood flow was 184.6±132.7 and 41.0±27.0 ml/min/100 g, arterial blood volume was 19.4±14.6 and 4.8±4.2 ml/100 g, and arterial mean transit time was 8.9±4.2 and 10.2±5.3 sec. Arterial blood flow and arterial blood volume correlated significantly with the vascularity of the tumor; however no correlation was detected between arterial mean transit time and the vascularity of the tumor. This technique could be used to quantify pure hepatic arterial blood perfusion. (author)

  3. Experimental study of CT perfusion in hepatitis, hepatic fibrosis and early stage of cirrhosis

    International Nuclear Information System (INIS)

    Guan Sheng; Zhao Weidong; Zhou Kangrong; Peng Weijun; Mao Jian; Tang Feng; Wang Yong; Cao Guang; Sun Fei

    2005-01-01

    Objective: To investigate the value of CT perfusion in the early diagnosis of hepatic diffuse disease. Methods: Fourteen male Wistar rats of control group and 14 of test group at stages of hepatitis, hepatic fibrosis, hepatic cirrhosis which were induced with diethylnitrosamine (DEN), were studied with CT perfusion respectively. CT perfusion data of different stages were compared and pathologic analysis were performed. Results: Density-time curves of CT perfusion were satisfactory and all perfusion data could be obtained. During the period of hepatitis developing into early stage of hepatic cirrhosis, hepatic artery flow (HAF) trended to increase in test group, mean transmit time (MTT) prolonged obviously, blood flow (BF) and volume (BV) declined. While in control group, HAF declined slightly, MTT, BV and BF increased. Statistic analysis showed the differences of HAF and MTT at different stages between control and test groups were significant (P<0.05 ); the differences of BV and BF between hepatitis and hepatic cirrhosis, hepatic fibrosis and early stage of hepatic cirrhosis in test group were significant (P<0.05), but no significant difference between hepatitis and hepatic fibrosis. The corresponding pathologic changes at stage of hepatitis was swelling of hepatic cells; sinusoids cap illarization and deposition of collagen in the extravascular Disse's spaces were the main changes relating to hepatic blood perfusion at stage of fibrosis and early stage of cirrhosis. Conclusion: The method of CT scan can reflect some changes of hepatic blood perfusion in rats with hepatitis, hepatic fibrosis and early stage of cirrhosis. The data of CT perfusion, especially the changes should be valuable for clinical early diagnosis, treatment and follow-up. (authors)

  4. Establishment of a hepatic cirrhosis and portal hypertension model by hepatic arterial perfusion with 80% alcohol.

    Science.gov (United States)

    Wang, Lei; He, Fu-Liang; Liu, Fu-Quan; Yue, Zhen-Dong; Zhao, Hong-Wei

    2015-08-28

    To determine the feasibility and safety of establishing a porcine hepatic cirrhosis and portal hypertension model by hepatic arterial perfusion with 80% alcohol. Twenty-one healthy Guizhou miniature pigs were randomly divided into three experimental groups and three control groups. The pigs in the three experimental groups were subjected to hepatic arterial perfusion with 7, 12 and 17 mL of 80% alcohol, respectively, while those in the three control groups underwent hepatic arterial perfusion with 7, 12 and 17 mL of saline, respectively. Hepatic arteriography and direct portal phlebography were performed on all animals before and after perfusion, and the portal venous pressure and diameter were measured before perfusion, immediately after perfusion, and at 2, 4 and 6 wk after perfusion. The following procedures were performed at different time points: routine blood sampling, blood biochemistry, blood coagulation and blood ammonia tests before surgery, and at 2, 4 and 6 wk after surgery; hepatic biopsy before surgery, within 6 h after surgery, and at 1, 2, 3, 4 and 5 wk after surgery; abdominal enhanced computed tomography examination before surgery and at 6 wk after surgery; autopsy and multi-point sampling of various liver lobes for histological examination at 6 wk after surgery. In experimental group 1, different degrees of hepatic fibrosis were observed, and one pig developed hepatic cirrhosis. In experimental group 2, there were cases of hepatic cirrhosis, different degrees of increased portal venous pressure, and intrahepatic portal venous bypass, but neither extrahepatic portal-systemic bypass circulation nor death occurred. In experimental group 3, two animals died and three animals developed hepatic cirrhosis, and different degrees of increased portal venous pressure and intrahepatic portal venous bypass were also observed, but there was no extrahepatic portal-systemic bypass circulation. It is feasible to establish an animal model of hepatic cirrhosis and

  5. Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion CT

    International Nuclear Information System (INIS)

    Tutcu, Semra; Serter, Selim; Kaya, Yavuz; Kara, Eray; Nese, Nalan; Pekindil, Goekhan; Coskun, Teoman

    2010-01-01

    Purpose: It is known that acute pancreatitis may cause secondary changes in several organs. Liver is one of these involved organs. In different experimental studies hepatic damages were shown histopathologically in acute pancreatitis but there are a few studies about perfusion disorders that accompany these histopathologic changes. Perfusion CT (pCT) provides the ability to detect regional and global alterations in organ blood flow. The purpose of the study was to describe hepatic perfusion changes in experimental acute pancreatitis model with pCT. Materials and methods: Forty Sprague-Dawley rats of both genders with average weights of 250 g were used. Rats were randomized into two groups. Twenty rats were in control group and 20 in acute pancreatitis group. pCT was performed. Perfusion maps were formed by processing the obtained images with perfusion CT software. Blood flow (BF) and blood volume (BV) values were obtained from these maps. All pancreatic and liver tissues were taken off with laparotomy and histopathologic investigation was performed. Student's t test was used for statistical analyses. Results: In pCT we found statistically significant increase in blood volume in both lobes of liver and in blood flow in right lobe of the liver (p < 0.01). Although blood flow in left lobe of the liver increased, it did not reach statistical significance. Conclusion: The quantitative analysis of liver parenchyma with pCT showed that acute pancreatitis causes a significant perfusion changes in the hepatic tissue. Systemic mediators seem to be effective as well as local inflammatory changes in perfusion changes.

  6. Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion CT

    Energy Technology Data Exchange (ETDEWEB)

    Tutcu, Semra [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey); Serter, Selim, E-mail: serterselim@gmail.co [Department of Radiology, Celal Bayar University, School of Medicine, Manisa (Turkey); Kaya, Yavuz; Kara, Eray [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey); Nese, Nalan [Department of Pathology, Celal Bayar University, School of Medicine, Manisa (Turkey); Pekindil, Goekhan [Department of Radiology, Celal Bayar University, School of Medicine, Manisa (Turkey); Coskun, Teoman [Department of Surgery, Celal Bayar University, School of Medicine, Manisa (Turkey)

    2010-08-15

    Purpose: It is known that acute pancreatitis may cause secondary changes in several organs. Liver is one of these involved organs. In different experimental studies hepatic damages were shown histopathologically in acute pancreatitis but there are a few studies about perfusion disorders that accompany these histopathologic changes. Perfusion CT (pCT) provides the ability to detect regional and global alterations in organ blood flow. The purpose of the study was to describe hepatic perfusion changes in experimental acute pancreatitis model with pCT. Materials and methods: Forty Sprague-Dawley rats of both genders with average weights of 250 g were used. Rats were randomized into two groups. Twenty rats were in control group and 20 in acute pancreatitis group. pCT was performed. Perfusion maps were formed by processing the obtained images with perfusion CT software. Blood flow (BF) and blood volume (BV) values were obtained from these maps. All pancreatic and liver tissues were taken off with laparotomy and histopathologic investigation was performed. Student's t test was used for statistical analyses. Results: In pCT we found statistically significant increase in blood volume in both lobes of liver and in blood flow in right lobe of the liver (p < 0.01). Although blood flow in left lobe of the liver increased, it did not reach statistical significance. Conclusion: The quantitative analysis of liver parenchyma with pCT showed that acute pancreatitis causes a significant perfusion changes in the hepatic tissue. Systemic mediators seem to be effective as well as local inflammatory changes in perfusion changes.

  7. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  8. Hepatic perfusion disorders: a pictorial review of CT and MR imaging

    International Nuclear Information System (INIS)

    Yim, Nam Yeol; Jeong, Yong Yeon; Shin, Sang Soo; Song, Sang Gook; Lim, Hyo Soon; Heo, Suk Hee; Chang, Nam Kyu; Yoon, Woong; Kang, Heoung Keun; Lan, Shen Yu

    2005-01-01

    The liver has a unique dual blood supply through the portal vein and the hepatic artery. There are several communications between these two vessels under various conditions such as in hepatic tumors, trauma and liver cirrhosis, vascular compromise, among others. When vascular compromise occurs, this dual blood supply system can cause changes in the volume of blood flow in individual vessels or even in the direction of blood flow. With rapid image acquisition and increased resolution available in multislice CT and MR imaging, hepatic perfusion disorders are now more frequently encountered than in the past. Familiarity with imaging findings of these perfusion disorders will be helpful in characterizing focal hepatic lesions and will also help to avoid false positive diagnoses

  9. Hepatic perfusion disorders: a pictorial review of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Nam Yeol; Jeong, Yong Yeon; Shin, Sang Soo; Song, Sang Gook; Lim, Hyo Soon; Heo, Suk Hee; Chang, Nam Kyu; Yoon, Woong; Kang, Heoung Keun [Chonnam National University, Gwangju (Korea, Republic of); Lan, Shen Yu [Yan Bian Cancer Hospital, Peijing (China)

    2005-09-15

    The liver has a unique dual blood supply through the portal vein and the hepatic artery. There are several communications between these two vessels under various conditions such as in hepatic tumors, trauma and liver cirrhosis, vascular compromise, among others. When vascular compromise occurs, this dual blood supply system can cause changes in the volume of blood flow in individual vessels or even in the direction of blood flow. With rapid image acquisition and increased resolution available in multislice CT and MR imaging, hepatic perfusion disorders are now more frequently encountered than in the past. Familiarity with imaging findings of these perfusion disorders will be helpful in characterizing focal hepatic lesions and will also help to avoid false positive diagnoses.

  10. Evaluation of hepatic hemangioma by Tc-99 m red blood cell hepatic blood pool scan

    International Nuclear Information System (INIS)

    Sohn, Myung Hee

    2005-01-01

    Hemangioma is the most common benign tumor of the liver, with a prevalence estimated as high as 7%. Tc-99m red blood cell (RBC) hepatic blood pool scan with single photon emission computed tomography (SPECT) imaging is extremely useful for the confirmation or exclusion of hepatic hemangiomas. The classic finding of absent or decreased perfusion and increased blood pooling ('perfusion/blood pool mismatch') is the key diagnostic element in the diagnosis of hemangiomas. The combination of early arterial flow and delayed blood pooling ('perfusion/blood pool match') is shown uncommonly. In giant hemangioma, filling with radioactivity appears first in the periphery, with progressive central fill-in on sequential RBC blood pool scan. However, the reverse filling pattern, which begins first in the center with progressive peripheral filling, is also rarely seen. Studies with false-positive blood pooling have been reported infrequently in nonhemangiomas, including hemangiosarcoma, hepatocellular carcinoma, hepatic adenoma, and metastatic carcinomas (adenocarcinma of the colon, small cell carcinoma of the lung, neruroendocrine carcinoma). False-negative results have been also reported rarely except for small hemagniomas that are below the limits of spatial resolution of gamma camera

  11. [Value of intravoxel incoherent motion diffusion-weighted imaging in differential diagnosis of benign and malignant hepatic lesions and blood perfusion evaluation].

    Science.gov (United States)

    Ying, M L; Xiao, W W; Xu, S L; Shu, J E; Pan, J F; Fu, J F; Lu, J H; Pan, Y H; Jiang, Y

    2016-11-20

    Objective: To investigate the value of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in the differential diagnosis and blood perfusion evaluation of benign and malignant hepatic lesions. Methods: A retrospective analysis was performed for 86 patients (96 lesions) with pathologically or clinically confirmed hepatic lesions or hepatic lesions diagnosed based on follow-up results, among whom 48 had malignant lesions (53 lesions) and 38 had benign lesions (43 lesions). The patients underwent conventional magnetic resonance (MR) plain scan, contrast-enhanced scan, and diffusion-weighted imaging (DWI) with different b values (b = 0, 50, 100, 150, 200, 400, 600, 800, 1 000, and 1 200 s/mm 2 ) to determine the parameters of the double exponential model for intravoxel incoherent motion (IVIM): fast diffusion coefficient Dfast, slow diffusion coefficient Dslow, and percentage of fast-diffusion constituent F value. The patients were divided into groups according to the blood supply to lesions on conventional MR plain scan and contrast-enhanced scan, and there were 47 lesions in abundant blood supply group and 49 in poor blood supply group. The data for analysis were Dfast, Dslow, and F values of benign/malignant lesion groups and abundant/poor blood supply groups. The independent samples t-test was used for statistical analysis; the independent samples non-parametric test Mann-Whitney U test was used for the comparison of F value; the receiver operating characteristic (ROC) curve was used to evaluate the value of above parameters in the differentiation of benign and malignant lesions and blood supply evaluation. Results: Compared with the malignant lesion group, the benign lesion group had significantly higher Dslow, and F values ( P benign and malignant hepatic lesions, and F value can show blood perfusion in benign and malignant hepatic lesions without the need for contrast-enhanced scan, which provides a reference for the qualitative diagnosis of liver

  12. Investigation of Hepatic Blood Perfusion by Laser Speckle Imaging and Changes of Hepatic Vasoactive Substances in Mice after Electroacupuncture

    Directory of Open Access Journals (Sweden)

    Xiao-jing Song

    2014-01-01

    Full Text Available The study was conducted to observe the effect of electroacupuncture (EA on hepatic blood perfusion (HBP and vascular regulation. We investigated 60 male anesthetized mice under the following 3 conditions: without EA stimulation (control group; EA stimulation at Zusanli (ST36 group; EA stimulation at nonacupoint (NA group during 30 min. The HBP was measured using the laser speckle perfusion imaging (LSPI. The level of nitric oxide (NO, endothelin-1 (ET-1, and noradrenaline (NE in liver tissue was detected by biochemical methods. Results were as follows. At each time point, HBP increase in ST36 group was higher than that in the NA group in anesthetized mice. HBP gradually decreased during 30 min in control group. The level of NO in ST36 group was higher than that in NA group. The level of both ET-1 and NE was the highest in control group, followed by NA group and ST36 group. It is concluded that EA at ST36 could increase HBP possibly by increasing the blood flow velocity (BFV, changing vascular activity, increasing the level of NO, and inhibiting the level of ET-1 in liver tissue.

  13. Computed Tomography Perfusion Imaging for the Diagnosis of Hepatic Alveolar Echinococcosis

    Science.gov (United States)

    Sade, Recep; Kantarci, Mecit; Genc, Berhan; Ogul, Hayri; Gundogdu, Betul; Yilmaz, Omer

    2018-01-01

    Objective: Alveolar echinococcosis (AE) is a rare life-threatening parasitic infection. Computed tomography perfusion (CTP) imaging has the potential to provide both quantitative and qualitative information about the tissue perfusion characteristics. The purpose of this study was the examination of the characteristic features and feasibility of CTP in AE liver lesions. Material and Methods: CTP scanning was performed in 25 patients who had a total of 35 lesions identified as AE of the liver. Blood flow (BF), blood volume (BV), portal venous perfusion (PVP), arterial liver perfusion (ALP), and hepatic perfusion indexes (HPI) were computed for background liver parenchyma and each AE lesion. Results: Significant differences were detected between perfusion values of the AE lesions and background liver tissue. The BV, BF, ALP, and PVP values for all components of the AE liver lesions were significantly lower than the normal liver parenchyma (p<0.01). Conclusions: We suggest that perfusion imaging can be used in AE of the liver. Thus, the quantitative knowledge of perfusion parameters are obtained via CT perfusion imaging. PMID:29531482

  14. Effects of Electroacupuncture Stimulation at “Zusanli” Acupoint on Hepatic NO Release and Blood Perfusion in Mice

    Directory of Open Access Journals (Sweden)

    Shu-you Wang

    2015-01-01

    Full Text Available The study is to observe the influence of electroacupuncture (EA stimulation at “Zusanli” (ST36 on the release of nitric oxide (NO and blood perfusion (BP in the liver and further explore whether the hepatic blood perfusion (HBP changes were regulated by EA ST36 induced NO in nitric oxide synthase inhibited mice. The HBP change of the mice was detected by laser speckle perfusion imaging (LSPI before and after being given interventions, and the NO in liver tissue was detected by nitric acid reductase in each group. The NO levels and HBP in the L-NAME group were significantly lower than those in the control group (P<0.01. The NO level and HBP increase in EA group were significantly higher than those in control group (P<0.05. The NO level in the L-NAME EA group was slightly higher than that in the L-NAME group. The HBP increase in the L-NAME EA group was not statistically significant. These results showed that EA could accelerate the synthesis of NO and thereby increase HBP via vasodilation in liver tissue.

  15. A relative study of hepatic perfusion and portal vein pressure in rats with liver cirrhosis

    International Nuclear Information System (INIS)

    Li Jiaping; Yang Jianyong; Chen Wei; Huang Yonghui

    2006-01-01

    Objective: To evaluate spiral CT perfusion in assessing portal vein pressure in rats with different stages of liver cirrhosis. Methods Seventeen rats with early stage of liver cirrhosis, 18 with intermediate stage, 12 with advanced stage, and 13 healthy rats as a control group were selected and recieved hepatic perfusion on a single-row spiral CT scanner. The parameters of hepatic perfusion were calculated using the deconvolution method. The portal vein pressure was measured by multi-physiographer. Results: (1) In study group, the PVP (portal venous perfusion) and THBP (total hepatic blood perfusion) were negatively correlated with FPP, while positively correlated with the HPI (hepatic perfusion index) and MTT (mean transit time). The FPP had a close relation with PVP. The equation, Y 20.671-3.195X, could be conducted with linear regression analysis. (2) According to the linear regression equation mentioned above, the FPP in 47 rats were 16.090±2.150 cmH 2 0, which was highly correlated with the observed valuel6.108±3.662 cmH 2 O (r=0.823 P<0.01). Conclusion: CT perfusion is a new non-invasive and efficient modality for assessment of the portal pressure in liver cirrhosis in various stages. (authors)

  16. CT hepatic perfusion measurement: Comparison of three analytic methods

    International Nuclear Information System (INIS)

    Kanda, Tomonori; Yoshikawa, Takeshi; Ohno, Yoshiharu; Kanata, Naoki; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2012-01-01

    Objectives: To compare the efficacy of three analytic methods, maximum slope (MS), dual-input single-compartment model (CM) and deconvolution (DC), for CT measurements of hepatic perfusion and assess the effects of extra-hepatic systemic factors. Materials and methods: Eighty-eight patients who were suspected of having metastatic liver tumors underwent hepatic CT perfusion. The scans were performed at the hepatic hilum 7–77 s after administration of contrast material. Hepatic arterial and portal perfusions (HAP and HPP, ml/min/100 ml) and arterial perfusion fraction (APF, %) were calculated with the three methods, followed by correlation assessment. Partial correlation analysis was used to assess the effects on hepatic perfusion values by various factors such as age, sex, risk of cardiovascular diseases, arrival time of contrast material at abdominal aorta, transit time from abdominal aorta to hepatic parenchyma, and liver dysfunction. Results: Mean HAP of MS was significantly higher than DC. HPP of CM was significantly higher than MS and CM, and HPP of MS was significantly higher than DC. There was no significant difference in APF. HAP and APF showed significant and moderate correlations among the methods. HPP showed significant and moderate correlations between CM and DC, and poor correlation between MS and CM or DC. All methods showed weak correlations between HAP or APF and age or sex. Finally, MS showed weak correlations between HAP or HPP and arrival time or cardiovascular risks. Conclusions: Hepatic perfusion values arrived at with the three methods are not interchangeable. CM and DC are less susceptible to extra-hepatic systemic factors

  17. Hepatic arterial perfusion increases in the early stage of severe acute pancreatitis patients: Evaluation by perfusion computed tomography

    International Nuclear Information System (INIS)

    Koyasu, Sho; Isoda, Hiroyoshi; Tsuji, Yoshihisa; Yamamoto, Hiroshi; Matsueda, Kazuhiro; Watanabe, Yuji; Chiba, Tsutomu; Togashi, Kaori

    2012-01-01

    Purpose: Although hepatic perfusion abnormalities have been reported in patients with acute pancreatitis, hepatic perfusion with severe acute pancreatitis (SAP) has not been quantitatively evaluated in humans. Therefore, we investigated hepatic perfusion in patients with SAP using perfusion CT. Materials and methods: Hepatic perfusion CT was performed in 67 patients with SAP within 3 days after symptom onset. The patients were diagnosed as having SAP according to the Atlanta criteria. Fifteen cases were established as a control group. Perfusion CT was obtained for 54 s beginning with a bolus injection of 40 ml of contrast agent (600–630 mgI/kg) at a flow rate of 4 ml/s. Perfusion data were analyzed by the dual-input maximum slope method to obtain hepatic arterial perfusion (HAP) and hepatic portal perfusion (HPP). Finally, we compared HAP and HPP in SAP patients with those in the control group, respectively. Results: Average HAP was significantly higher in SAP patients than in the control group (75.1 ± 38.0 vs. 38.2 ± 9.0 ml/min/100 ml; p < 0.001). There was no significant difference in average HPP between SAP patients and the control group (206.7 ± 54.9 vs. 204.4 ± 38.5 ml/min/100 ml; p = 0.92). Conclusion: Using quantitative analysis on perfusion CT, we first demonstrated an increase of HAP in the right hepatic lobe in SAP patients.

  18. Affection of blood supply of focal hepatic mass on apparent diffusion coefficient of the lesions

    International Nuclear Information System (INIS)

    Chen Zaizhi; Wu Yulin; Xu Zhongfei; Yang Zhenghan; Chen Min; Zhou Cheng; Xie Jingxia

    2002-01-01

    Objective: To investigate the affection of lesion blood supply on apparent diffusion coefficient (ADC) of focal hepatic mass. Methods: Diffusion-weighted imaging (DWI) with different b values was performed in 87 patients with 159 focal hepatic lesions. ADCs of lesion, liver, spleen, gallbladder were measured in every case. Results: On DWI with small b value and small b value remainder, ADCs were affected by blood perfusion of tissues or lesions. The mean ADC of hypervascular lesions was significantly higher than that of hypovascular lesions on DWI with small b value, and hemoangiomas got the highest mean ADC. The mean ADC of hepatic cysts was not affected by b value. Conclusion: Blood perfusion affects ADC of tissue or focal hepatic lesion, particularly on DWI with small b value, and to some degree, DWI and ADC can reflect the blood supply of focal hepatic lesion

  19. Hepatic Arterial Perfusion Scintigraphy with '99mTc-Macroaggregated Albumin in Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Kim, Gang Deuk; Sohn, Kwang Joon; Min, Kyung Yoon; Kwon, Young Mi; Kim, Chang Guhn; Noh, Byung Suk; Won, Jong Jin

    1994-01-01

    Hepatic arterial perfusion scintigraphy with '9 9m Tc macroggregated albumin (HAPS) study was carried out in 16 patients with hepatocellular carcinoma (HCC) and in six patients without liver tumor to evaluate HAPS findings of hepatocellular carcinoma and use fullness of HAPS. HAPS with planar and SPECT study were performed in 22 patients after conventional hepatic or celiac arteriography. For HAPS study, 4 5 mCi of MAA mixed with 2 ml of saline was injected into proper hepatic artery or its distal branches at the rate of approximately 1 ml/sec. We analysed 21 HCCs over 2 cm in diameter(average diameter: 6.4 cm) and 17 of 21 HCCs were over 4 cm in diameter. CT, sonography and angiography were performed within two week in all 16 patients and liver scan was performed in 12 patients. Three different pattern of tumor perfusion were observed in 16 patients with HCC. 1) diffuse increased perfusion in 16 of 21(76%) 2) increased peripheral perfusion in 4 of 21(19%) 3) diffuse decreased perfusion in 1 of 21 (5%) Arteriovenous shunt indicated by lung uptake of MAA were observed in 9 of 16 (56% ). In contrast, angiography demonstrates arteriovenous shunt in 2 of 16 (13%). There was no accumulation of radioactivity on RRC blood pool scan in all six patients with HCC examined. HAPS is useful study in evaluation of perfusion pattern or vascularity of HCC and in detection of arteriovenous shunt.

  20. Study of a new method for the evaluation of portal vein pressure by hepatic perfusion imaging

    International Nuclear Information System (INIS)

    Cheng Muhua; Ling Yunbiao; Pan Zhiheng; Zhang Feng; Chen Weizhen

    2002-01-01

    To study a new method for predication of portal vein pressure (PVP) by hepatic perfusion imaging. 25 hepato-cirrhotic cases and 13 normal controls were performed the hepatic perfusion imaging. According to two compartmental model the values of portal vein indexes (PVI) was calculated using curve slope, area and hepatic heart perfusion ratio methods etc. The relationship of PVI with different method to PVP was also observed. All PVI by three methods in hepatocirrhosis were higher than those in normal controls (P<0.01), and also positively correlated with the PVP, their correlated coefficients was 0.79, 0.60, 0.68 respectively. Among them the slope method was most markedly significant than normal control and closely correlated with PVP. PVI can sensitively reflect the changes of portal vein blood flow. And it was an atraumatic, simple method for the evaluation of PVP

  1. Evaluation of portal hypertension: a comparison of the use of liver perfusion CT with wedge hepatic venous pressure and hepatic

    International Nuclear Information System (INIS)

    Chung, Dong Jin; Kim, Young Joong; Park, Yong Sung; Lee, Tae Hee; Kim, Chong Soo; Kang, Heung Keun

    2008-01-01

    We compared the hepatic perfusion indices obtained using hepatic perfusion CT with the wedge hepatic venous pressure (WHVP) and hepatic venous pressure gradient (HVPG) to determine the efficacy of the use of liver perfusion CT for the evaluation of portal hypertension. Thirty-five patients with liver cirrhosis underwent hepatic vein catheterization to measure WHVP and HVPG and underwent a liver perfusion CT examination. Arterial perfusion, portal perfusion, total perfusion and the hepatic perfusion index (HPI) were calculated by the methods described by Miles and Blomlely. The overall correlation coefficients (r) between the perfusion indices and WHVP and HVPG were calculated. An additional correlation coefficient of 23 alcoholic cirrhosis patients was calculated. Using Blomley's equation, HPI had a positive correlation with WHVP (r = .471; ρ < .05) and HVPG (r = .482; ρ < .05). For the alcoholic liver cirrhosis patients, HPI had a higher positive correlation with WHVP (r = .500; ρ < .05) and HVPG (r = .539; ρ < .05) than for the non-alcoholic cirrhosis patients. There was no statistical difference between the use of Miles' equation and Blomley's equation for the evaluation of portal hypertension. This preliminary study showed that HPI positively correlated with WHVP and HVPG, especially in alcoholic cirrhosis patients. Liver perfusion CT may be useful in the evaluation of portal hypertension

  2. Evaluation of portal hypertension: a comparison of the use of liver perfusion CT with wedge hepatic venous pressure and hepatic

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Dong Jin; Kim, Young Joong; Park, Yong Sung; Lee, Tae Hee [University of Konyang College of Medicine, Daejeon (Korea, Republic of); Kim, Chong Soo; Kang, Heung Keun [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2008-09-15

    We compared the hepatic perfusion indices obtained using hepatic perfusion CT with the wedge hepatic venous pressure (WHVP) and hepatic venous pressure gradient (HVPG) to determine the efficacy of the use of liver perfusion CT for the evaluation of portal hypertension. Thirty-five patients with liver cirrhosis underwent hepatic vein catheterization to measure WHVP and HVPG and underwent a liver perfusion CT examination. Arterial perfusion, portal perfusion, total perfusion and the hepatic perfusion index (HPI) were calculated by the methods described by Miles and Blomlely. The overall correlation coefficients (r) between the perfusion indices and WHVP and HVPG were calculated. An additional correlation coefficient of 23 alcoholic cirrhosis patients was calculated. Using Blomley's equation, HPI had a positive correlation with WHVP (r = .471; {rho} < .05) and HVPG (r = .482; {rho} < .05). For the alcoholic liver cirrhosis patients, HPI had a higher positive correlation with WHVP (r = .500; {rho} < .05) and HVPG (r = .539; {rho} < .05) than for the non-alcoholic cirrhosis patients. There was no statistical difference between the use of Miles' equation and Blomley's equation for the evaluation of portal hypertension. This preliminary study showed that HPI positively correlated with WHVP and HVPG, especially in alcoholic cirrhosis patients. Liver perfusion CT may be useful in the evaluation of portal hypertension.

  3. Unsatisfactory hepatic perfusion after placement of the infusaid pump: Angiographic correlation

    International Nuclear Information System (INIS)

    Andrews, J.C.; Williams, D.M.; Cho, K.J.; Knol, J.A.; Wahl, R.L.; Ensminger, W.D.

    1988-01-01

    Complete perfusion limited to the liver is essential to the success of regional chemotherapy for hepatic malignancy. Thirty-three patients with unsatisfactory hepatic artery perfusion scintigrams after surgical placement of a pump and catheter system were evaluated with selective angiography (31 cases) or digital subtraction angiography (DSA) via the pump side port (six cases). The cause of the perfusion defect was hepatic artery thrombosis (14 cases), extrahepatic flow through collaterals (13 cases), misplaced catheter (three cases), short proper hepatic artery without adequate length for mixing (two cases), and undefined (one case). DSA findings were diagnostic in only two cases. Angiographic findings directed attempted correction in 22 of 33 cases

  4. Quantitative hepatic CT perfusion measurement: Comparison of Couinaud's hepatic segments with dual-source 128-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xuan [The Department of Radiology, Peking Union Medical College Hospital, Dongcheng District, Beijing, 100730 (China); Xue, Hua-dan, E-mail: bjdanna95@hotmail.com [The Department of Radiology, Peking Union Medical College Hospital, Dongcheng District, Beijing, 100730 (China); Jin, Zheng-yu, E-mail: jin_zhengyu@163.com [The Department of Radiology, Peking Union Medical College Hospital, Dongcheng District, Beijing, 100730 (China); Su, Bai-yan; Li, Zhuo; Sun, Hao; Chen, Yu; Liu, Wei [The Department of Radiology, Peking Union Medical College Hospital, Dongcheng District, Beijing, 100730 (China)

    2013-02-15

    Purpose: To compare the quantitative liver computed tomography perfusion (CTP) differences among eight hepatic segments. Materials and methods: This retrospective study was based on 72 acquired upper abdomen CTP scans for detecting suspected pancreas tumor. Patients with primary or metastatic liver tumor, any focal liver lesions except simple cyst (<3 cm in diameter), history of liver operation or splenectomy, evidence of liver cirrhosis or invasion of portal vein were excluded. The final analysis included 50 patients (M:F = 21:29, mean age = 43.2 years, 15–76 years). Arterial liver perfusion (ALP), portal-venous perfusion (PVP), total hepatic perfusion (THP = ALP + PVP), and hepatic perfusion index (HPI) of each hepatic segment were calculated and compared by means of one-way analysis of variance (ANOVA) and the Bonferonni correction method. Results: Compared to hepatic segments 5, 6, 7 and 8, segments 2 and 3 showed a tendency of higher ALPs, lower PVPs, and higher HPIs, most of which were statistically significant (p < 0.05). Hepatic segments 1 and 4 had higher mean values of ALP and HPI and lower mean values of PVP than segments 5, 6, 7 and 8 as well, although no significant differences were detected except for ALP and HPI for liver segments 1 and 7 (p = 0.001 and 0.035 respectively), and ALP for liver segments 1 and 5 (p = 0.039). Higher ALP and HPI were showed in hepatic segment 3 compared to segment 4 (p = 0.000 and 0.000 respectively). No significant differences were found for THP among eight segments. Conclusions: Intra-hepatic perfusion differences exist in normal hepatic parenchyma especially between lateral sector (segments 2 and 3) and right lobe (segments 5, 6, 7 and 8). This might have potential clinical significance in liver-perfusion-related protocol design and result analysis.

  5. Percutaneous Hepatic Perfusion (PHP) with Melphalan as a Treatment for Unresectable Metastases Confined to the Liver.

    Science.gov (United States)

    de Leede, Eleonora M; Burgmans, Mark C; Martini, Christian H; Tijl, Fred G J; van Erkel, Arian R; Vuyk, Jaap; Kapiteijn, Ellen; Verhoef, Cornelis; van de Velde, Cornelis J H; Vahrmeijer, Alexander L

    2016-07-31

    Unresectable liver metastases of colorectal cancer can be treated with systemic chemotherapy, aiming to limit the disease, extend survival or turn unresectable metastases into resectable ones. Some patients however, suffer from side effects or progression under systemic treatment. For patients with metastasized uveal melanoma there are no standard systemic therapy options. For patients without extrahepatic disease, isolated liver perfusion (IHP) may enable local disease control with limited systemic side effects. Previously, this was performed during open surgery with satisfying results, but morbidity and mortality related to the open procedure, prohibited a widespread application. Therefore, percutaneous hepatic perfusion (PHP) with simultaneous chemofiltration was developed. Besides decreasing morbidity and mortality, this procedure can be repeated, hopefully leading to a higher response rate and improved survival (by local control of disease). During PHP, catheters are placed in the proper hepatic artery, to infuse the chemotherapeutic agent, and in the inferior caval vein to aspirate the chemosaturated blood returning through the hepatic veins. The caval vein catheter is a double balloon catheter that prohibits leakage into the systemic circulation. The blood returning from the hepatic veins is aspirated through the catheter fenestrations and then perfused through an extra-corporeal filtration system. After filtration, the blood is returned to the patient by a third catheter in the right internal jugular vein. During PHP a high dose of melphalan is infused into the liver, which is toxic and would lead to life threatening complications when administered systemically. Because of the significant hemodynamic instability resulting from the combination of caval vein occlusion and chemofiltration, hemodynamic monitoring and hemodynamic support is of paramount importance during this complex procedure.

  6. Management of Liver Cancer Argon-helium Knife Therapy with Functional Computer Tomography Perfusion Imaging.

    Science.gov (United States)

    Wang, Hongbo; Shu, Shengjie; Li, Jinping; Jiang, Huijie

    2016-02-01

    The objective of this study was to observe the change in blood perfusion of liver cancer following argon-helium knife treatment with functional computer tomography perfusion imaging. Twenty-seven patients with primary liver cancer treated with argon-helium knife and were included in this study. Plain computer tomography (CT) and computer tomography perfusion (CTP) imaging were conducted in all patients before and after treatment. Perfusion parameters including blood flows, blood volume, hepatic artery perfusion fraction, hepatic artery perfusion, and hepatic portal venous perfusion were used for evaluating therapeutic effect. All parameters in liver cancer were significantly decreased after argon-helium knife treatment (p knife therapy. Therefore, CTP imaging would play an important role for liver cancer management followed argon-helium knife therapy. © The Author(s) 2014.

  7. Hepatic computed tomography perfusion. Comparison of maximum slope and dual-input single-compartment methods

    International Nuclear Information System (INIS)

    Kanda, Tomonori; Yoshikawa, Takeshi; Ohno, Yoshiharu; Kanata, Naoki; Koyama, Hisanobu; Nogami, Munenobu; Takenaka, Daisuke; Sugimura, Kazuro

    2010-01-01

    The aim of the study was to compare two analytical methods-maximum slope (MS) and the dualinput single-compartment model (CM)-in computed tomography (CT) measurements of hepatic perfusion and to assess the effects of extrahepatic systemic factors. A total of 109 patients underwent hepatic CT perfusion. The scans were conducted at the hepatic hilum 7-77 s after administration of contrast material. Hepatic arterial perfusion (HAP) and portal perfusion (HPP) (ml/min/100 ml) and the arterial perfusion fraction (APF, %) were calculated with the two methods, followed by correlation assessment. Partial correlation analysis was used to assess the effects on hepatic perfusion values by various factors, including age, sex, risk of cardiovascular disease, compensation for respiratory misregistration, arrival time of contrast material at the abdominal aorta, transit time from abdominal aorta to hepatic parenchyma, and liver dysfunction. The mean HAPs, HPPs, and APFs were, respectively, 31.4, 104.2, and 23.9 for MS and 27.1, 141.3, and 22.1 for CM. HAP and APF showed significant (P<0.0001) and moderate correlation (γ=0.417 and 0.548) and HPP showed poor correlation (γ=0.172) between the two methods. While MS showed weak correlations (γ=-0.39 to 0.34; P<0.001 to <0.02) between multiple extrahepatic factors and perfusion values, CM showed weak correlation only between the patients' sex and HAP (γ=0.31, P=0.001). Hepatic perfusion values estimated by the two methods are not interchangeable. CM is less susceptible to extrahepatic systemic factors. (author)

  8. Nursing implications for Hepatic arterial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Ellender, R.

    1999-01-01

    Nurses working in Nuclear Medicine assist in Hepatic Artery Catheter (HAC) perfusion studies. This scan is not widely performed in Australia, the St George hospital for example performs approximately five per year. The purpose of this article is firstly to review the indications and rationale of HAC patency studies. Secondly, this article will stress the clinical implications for the Nuclear Medicine Nurse during this study. Emphasis will be placed on the importance of patient education during the procedure. A brief overview of hepatic anatomy and the radiopharmaceuticals administered during the scan is discussed. Finally, a step by step protocol is presented to show how the perfusion/ shunt study is performed. Copyright (1999) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. Studies on blood supply of liver metastasis with DSA, CT and portal vein perfusion CT during superior mesenteric arterial portography

    International Nuclear Information System (INIS)

    Li Zhigang; Shi Gaofeng; Huang Jingxiang; Li Shunzong; Liang Guoqing; Wang Hongguang; Han Pengyin; Wang Qi; Gu Tieshu

    2008-01-01

    Objective: To probe the blood supply of liver metastasis by celiac artery, proper hepatic artery DSA, portal vein perfusion CT during superior mesenteric arterial portography (PCTAP). Methods: One hundred patients with liver metastases were examined prospectively by plain CT scan, multiphase enhanced CT scan, celiac arteriography and proper hepatic arteriography. Of them, 56 patients were examined by PCTAP. All primary lesions were confirmed by operation and (or) pathology examination. In order to investigate the blood supply of metastasis lesions, the software of Photoshop was used to obtain the time-attenuation curves (TDC) of tumor center, tumor edge, portal vein and normal liver parenchyma adjacent to the tumor to calculate liver perfusion for DSA image analysis, while a deconvolution model from CT perfusion software was designed for the dual blood supply. Results: DSA findings: TDC of proper hepatic arteriography showed: the mean peak concentration (K value) in tumor centers was (67 ± 12)%, and it was (76 ± 15)% for peritumor tissue, (51 ± 10)% in normal liver parenchyma. TDC of celiac arteriogaphy showed that the contrast concentration of tumor centers and tumor edge increased fast in early stage, then maintained a slight upward plateau, in the meanwhile, the contrast concentration of normal liver parenchyma kept increasing slowly. PCTAP findings: tumors exhibited no enhancement during 30 s continued scans. Conclusion: The blood supply of liver metastasis mainly comes from hepatic artery, but barely from portal vein. (authors)

  10. Visceral Perfusion Scintigraphy with {sup 131}I-Labelled Albumin Macroaggregates

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, H.; Yamada, H.; Kitani, K.; Nagatani, M.; Takeda, T.; Migita, T.; Iio, M; Kameda, H. [University of Tokyo, Tokyo (Japan)

    1969-05-15

    The blood supply through the hepatic artery, superior mesenteric artery and portal vein to the visceral organs was studied in 60 cases of various hepatic disorders by scintigraphy after the selective introduction of {sup 131}I MAA by means of visceral arterial catheterization or percutaneous splenic puncture. A comparison of the radioactivities of the liver and the spleen after celiac arterial infusion (celiac perfusion scanning) indicated how much blood in the celiac artery was distributed to the two major arterial branches - the hepatic and splenic. Dominant perfusion was found through the hepatic branch in liver cirrhosis, whereas significantly dominant splenic blood perfusion was found in idiopathic non-cirrhotic portal hypertension. This remarkable contrast of the mode of celiac perfusion in two disorders indicated the etiological difference of these diseases. In malignant neoplasm of the liver, the dominant or exclusive celiac arterial perfusion was found in the tumour region. In these cases, liver scanning by the splenic injection of MAA (portal perfusion scanning) delineated the tumour region as a negative defect similar to the conventional {sup 198}Au colloid scanning. Consequently, from these two perfusion scintigrams the 'key and key-hole' pattern was demonstrated. It was concluded that a neoplastic lesion, primary or metastatic, has the predominant blood supply through the hepatic artery rather than through the portal vein. Celiac perfusion scanning of liver cystosis revealed multiple negative defects. This information was useful for differentiating a malignant tumour, which is usually impossible by conventional liver scanning. Celiac perfusion scanning was also useful for the diagnosis of arterial venous communication. In one case of liver .cancer with cirrhosis and another case with stomach varices, the arterial-v.enous communication was indicated by the appearance of the lung contour in the celiac perfusion scan. In both cases, the combined presence

  11. Comparative study of rabbit VX2 hepatic implantation tumor and normal liver tissue on magnetic resonance perfusion weighted imaging

    International Nuclear Information System (INIS)

    Jiao Zimei; Wang Xizhen; Wang Bin; Liu Feng; Li Haiqing; Sun Yequan; Dong Peng

    2012-01-01

    Objective: To investigate the value of magnetic resonance (MR) perfusion weighted imaging (PWI) in evaluating the blood perfusion of tumor by analyzing the features and indexes of PWI on rabbit VX2 hepatic implantation tumor and normal liver tissue. Methods: Twenty-four New Zealand White rabbits with VX2 carcinoma were established under direct surgical vision embedding tumor tissue. MR examination was performed at 21 days after the tumor implantation. The signal intensity -time curve of hepatic tumor and normal liver tissue were obtained. Mean time to enhance (MTE), negative enhancement integral (NEI), time to minimum (TM), maximum slope of decrease (MSD) and maximum slope of increase (MSI) were measured. Results: MTE, NEI, TM, MSD, and MSI of the normal liver tissue were 208.341±2.226 ms, 78.334±8.152, 24.059±1.927 ms, 38.221±2.443, and 15.389±2.526, respectively. MTE, NEI, TM, MSD, and MSI of the tumor tissue were 175.437±4.182 ms, 123.203±19.455, 17.061±1.834 ms, 125.740±4.842, and 67.832±2.882, respectively. The MTE and TM of tumor were shorter than those of normal hepatic tissue (P<0.05). NEI, MSD, and MSI of tumor were higher than those of normal hepatic tissue (P<0.05). Conclusion: PWI can distinguish the normal liver tissue from the tumor tissue, which is helpful in evaluating blood perfusion of different hepatic tissues. (authors)

  12. Hepatic artery perfusion imaging

    International Nuclear Information System (INIS)

    Thrall, J.H.; Gyves, J.W.; Ziessman, H.A.; Ensminger, W.D.

    1985-01-01

    Organ and region-selective intra-arterial chemotherapy have been used for more than two decades to treat malignant neoplasms in the extremities, head and neck region, pelvis, liver, and other areas. Substantial evidence of improved response to regional chemotherapy now exists, but there are stringent requirements for successful application of the regional technique. First, the chemotherapeutic agent employed must have appropriate pharmacokinetic and pharmacodynamic properties. Second, the drug must be reliably delivered to the tumor-bearing area. This typically requires an arteriographic assessment of the vascular supply of the tumor, followed by placement of a therapeutic catheter and confirmation that the ''watershed'' perfusion distribution from the catheter truly encompasses the tumor. Optimal catheter placement also minimizes perfusion of nontarget organs. Radionuclide perfusion imaging with technetium 99m-labeled particles, either microspheres or macroaggregates of albumin, has become the method of choice for making these assessments. Catheter placement itself is considered by many to represent a type of ''therapeutic'' intervention. However, once the catheter is in the hepatic artery the radionuclide perfusion technique can be used to assess adjunctive pharmacologic maneuvers designed to further exploit the regional approach to chemotherapy. This chapter presents the technetium Tc 99m macroaggregated albumin method for assessing catheter placement and the pharmacokinetic rationale for regional chemotherapy, and discusses two promising avenues for further intervention

  13. Changes in hepatic perfusion index determined by Tc-99m pertechnetate first pass scintigraphy in acute viral hepatitis

    International Nuclear Information System (INIS)

    Ali, M.K.

    1993-01-01

    Computerized sequential radionuclide angiography was used to analyze the first pass kinetics of peripherally injected bolus of Tc-99m-pertechnetate. The relative arterial/total hepatic blood flow, the Hepatic Perfusion Index (HPI%), was determined in normal subjects while 20 cases of Acute Viral Hepatitis (AVH) were studied serially. In addition, biochemical blood analysis as also carried out. The mean value of HPI in first study of all patients was 61.23% in comparison to 31.12% of control group. The patients were divided into three groups, based upon the duration elapsed between the onset of symptoms and the first study. HPI was found significantly high in first study of each group as compared to controls. In first group there was no significant correlation of mean HPI with other biochemical parameters. In second and third groups, significant correlation were observed between the mean HPI and serum bilirubin, serum alanine trans-aminase with mean HPI in the third group. The serum proteins correlated negatively with HPI in second group. This technique offers a simple, rapid, non-invasive and quantitative method to determine a new index which mostly behaves like other biochemical parameter and can be used to follow the course of acute viral hepatitis. (author)

  14. Possibilities of differentiation of solitary focal liver lesions by computed tomography perfusion

    Directory of Open Access Journals (Sweden)

    Irmina Sefić Pašić

    2015-08-01

    Full Text Available Aim To evaluate possibilities of computed tomography (CT perfusion in differentiation of solitary focal liver lesions based on their characteristic vascularization through perfusion parameters analysis. Methods Prospective study was conducted on 50 patients in the period 2009-2012. Patients were divided in two groups: benign and malignant lesions. The following CT perfusion parameters were analyzed: blood flow (BF, blood volume (BV, mean transit time (MTT, capillary permeability surface area product (PS, hepatic arterial fraction (HAF, and impulse residual function (IRF. During the study another perfusion parameter was analyzed: hepatic perfusion index (HPI. All patients were examined on Multidetector 64-slice CT machine (GE with application of perfusion protocol for liver with i.v. administration of contrast agent. Results In both groups an increase of vascularization and arterial blood flow was noticed, but there was no significant statistical difference between any of 6 analyzed parameters. Hepatic perfusion index values were increased in all lesions in comparison with normal liver parenchyma. Conclusion Computed tomography perfusion in our study did not allow differentiation of benign and malignant liver lesions based on analysis of functional perfusion parameters. Hepatic perfusion index should be investigated in further studies as a parameter for detection of possible presence of micro-metastases in visually homogeneous liver in cases with no lesions found during standard CT protocol

  15. Analysis of liver blood flow by dynamic hepatic scintigraphy

    International Nuclear Information System (INIS)

    Xie Tianhao; Jia Shiquan

    1996-01-01

    Liver blood flow was studied in 45 patients with solitary malignant liver cancer, 17 patients with multiple liver metastases, 18 patients with benign liver tumor and 20 control subjects by dynamic hepatic scintigraphy. The hepatic perfusion index (HPI) in control subjects, patients with liver malignant cancer and benign tumor was 0.33 +- 0.069, 0.589 +- 0.084, 0.384 +-0.046 respectively, and the mesenteric fraction (MF) was 0.56 +- 0.054, 0.246 +- 0.064, 0.524 +- 0.086 respectively. In conclusion, flow scintigraphy is a non-invasive, sensitive and repeatable method for detection of liver tumor

  16. Radionuclide hepatic perfusion index and ultrasonography: Assessment of portal hypertension in clinical practice

    International Nuclear Information System (INIS)

    Seidlova, V.; Hobza, J.; Pumprla, J.; Charouzek, J.

    1989-01-01

    The application is described of radionuclide angiography with hepatic perfusion index (HPI) determination in diagnosis of portal blood flow as an indicator of portal hypertension. 99m Tc and 113 In were used as tracers. Over forty patients suffering from chronic hepatitis or liver cirrhosis were included in the study. Ultrasound was used as a preliminary rapid diagnosis of portal hypertension. Radionuclide angiography combined with the HPI technique was confirmed to be a beneficial noninvasive method offering reproducible quantitative information on portal flow well correlating with the degree of portal hypertension, while the combination of ultrasound examination with radionuclide HPI determination appears to greatly enrich the diagnostic potential in hepatology. (L.O.). 4 figs., 11 refs

  17. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    International Nuclear Information System (INIS)

    Cao Wei; Li Jing; Wu Zhiqun; Zhou Changxi; Liu Xi; Wan Yi; Duan Yunyou

    2013-01-01

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 °C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 °C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  18. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Cao Wei, E-mail: cawe-001@163.com [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Li Jing, E-mail: lijing02@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Burn and Plastic Surgery (China); Wu Zhiqun, E-mail: zhiqunwu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Zhou Changxi, E-mail: changxizhou@163.com [Chinese PLA General Hospital, Department of Respiratory Disease (China); Liu Xi, E-mail: xiliu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China); Wan Yi, E-mail: yiwan@163.com [The Fourth Military Medical University, Department of Health Statistics, Institute for Health Informatics (China); Duan Yunyou, E-mail: yunyouduan@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China)

    2013-06-15

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 Degree-Sign C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 Degree-Sign C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  19. CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    International Nuclear Information System (INIS)

    Talakic, Emina; Schoellnast, Helmut; Schaffellner, Silvia; Kniepeiss, Daniela; Mueller, Helmut; Stauber, Rudolf; Quehenberger, Franz

    2017-01-01

    To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volume scanner as well as invasive measurement of HVPG. Different CT perfusion algorithms (maximum slope analysis and Patlak plot) were used to measure hepatic arterial flow (HAF), portal venous flow (PVF), hepatic perfusion index (HPI), splenic arterial flow (SAF), splenic blood volume (SBV) and splenic clearance (SCL). Hepatic and splenic perfusion parameters were correlated with HVPG, and sensitivity and specificity for detection of severe portal hypertension (≥12 mmHg) were calculated. The Spearman correlation coefficient was -0.53 (p < 0.05) between SAF and HVPG, and -0.68 (p < 0.01) between HVPG and SCL. Using a cut-off value of 125 ml/min/100 ml for SCL, sensitivity for detection of a HVPG of ≥12 mmHg was 94%, and specificity 100%. There was no significant correlation between hepatic perfusion parameters and HVPG. CT perfusion in patients with cirrhosis showed a strong correlation between SCL and HVPG and may be used for detection of severe portal hypertension. (orig.)

  20. CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    Energy Technology Data Exchange (ETDEWEB)

    Talakic, Emina; Schoellnast, Helmut [Medical University of Graz, Division of General Radiology, Department of Radiology, Graz (Austria); Schaffellner, Silvia; Kniepeiss, Daniela; Mueller, Helmut [Medical University of Graz, Department of Surgery, Division of Transplantation Surgery, Graz (Austria); Stauber, Rudolf [Medical University of Graz, Department of Internal Medicine, Division of Gastoenterology and Hepatology, Graz (Austria); Quehenberger, Franz [Medical University of Graz, Institute for Medical Informatics, Statistics and Documentation, Graz (Austria)

    2017-10-15

    To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volume scanner as well as invasive measurement of HVPG. Different CT perfusion algorithms (maximum slope analysis and Patlak plot) were used to measure hepatic arterial flow (HAF), portal venous flow (PVF), hepatic perfusion index (HPI), splenic arterial flow (SAF), splenic blood volume (SBV) and splenic clearance (SCL). Hepatic and splenic perfusion parameters were correlated with HVPG, and sensitivity and specificity for detection of severe portal hypertension (≥12 mmHg) were calculated. The Spearman correlation coefficient was -0.53 (p < 0.05) between SAF and HVPG, and -0.68 (p < 0.01) between HVPG and SCL. Using a cut-off value of 125 ml/min/100 ml for SCL, sensitivity for detection of a HVPG of ≥12 mmHg was 94%, and specificity 100%. There was no significant correlation between hepatic perfusion parameters and HVPG. CT perfusion in patients with cirrhosis showed a strong correlation between SCL and HVPG and may be used for detection of severe portal hypertension. (orig.)

  1. Measurement of hepatic volume and effective blood flow with radioactive colloids: Evaluation of development in liver diseases

    International Nuclear Information System (INIS)

    Fujii, M.; Uchino, H.; Kyoto Univ.

    1982-01-01

    Changes in hepatic volume and the blood flow effectively perfusing the liver parenchyma were studied as an assessment of the severity of liver diseases. Hepatic effective blood flow was estimated as the hepatic fractional clearance of radioactive colloids, obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic fractional clearance was normal or not markedly decreased in patients with acute hepatitis which had developed favorably, but was severely decreased in patients with fulminant hepatitis. In liver diseases, the ratio of hepatic volume to fractional clearance was found to increase as the clearance decreased. In subjects with normal clearance, hepatic fractional clearance was correlated significantly with liver volume, indicating that hepatic effective blood flow is proportional to parenchymal volume in an unanesthetized, resting state. In biopsied cases changes in volume and blood flow accorded well with changes indicated by morphological criteria. In chronic persistent hepatitis, effective hepatic blood flow is not diminished. However, hepatic blood flow were observed between the cirrhosis or chronic aggressive hepatitis, and normal control groups. Extension of chronic inflammatory infiltration into the parenchyma distinguishes chronic aggressive hepatitis from chronic persistent hepatitis. Architecture is often disturbed in the former. These changes should be accompanied by disturbance of microcirculation. The present study indicates that the decrease in effective hepatic blood flow in chronic hepatitis and cirrhosis has two aspects: one is a summation of microcirculatory disturbances, and the other is a decrease in liver cell mass. (orig.)

  2. CT Perfusion Characteristics Identify Metastatic Sites in Liver

    Directory of Open Access Journals (Sweden)

    Yuan Wang

    2015-01-01

    Full Text Available Tissue perfusion plays a critical role in oncology because growth and migration of cancerous cells require proliferation of new blood vessels through the process of tumor angiogenesis. Computed tomography (CT perfusion is an emerging functional imaging modality that measures tissue perfusion through dynamic CT scanning following intravenous administration of contrast medium. This noninvasive technique provides a quantitative basis for assessing tumor angiogenesis. CT perfusion has been utilized on a variety of organs including lung, prostate, liver, and brain, with promising results in cancer diagnosis, disease prognostication, prediction, and treatment monitoring. In this paper, we focus on assessing the extent to which CT perfusion characteristics can be used to discriminate liver metastases from neuroendocrine tumors from normal liver tissues. The neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow (BF, blood volume (BV, mean transit time (MTT, permeability (PS, and hepatic arterial fraction (HAF, for tumor and normal liver. The result reveals the potential of CT perfusion as a tool for constructing biomarkers from features of the hepatic vasculature for guiding cancer detection, prognostication, and treatment selection.

  3. CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    Science.gov (United States)

    Talakić, Emina; Schaffellner, Silvia; Kniepeiss, Daniela; Mueller, Helmut; Stauber, Rudolf; Quehenberger, Franz; Schoellnast, Helmut

    2017-10-01

    To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volume scanner as well as invasive measurement of HVPG. Different CT perfusion algorithms (maximum slope analysis and Patlak plot) were used to measure hepatic arterial flow (HAF), portal venous flow (PVF), hepatic perfusion index (HPI), splenic arterial flow (SAF), splenic blood volume (SBV) and splenic clearance (SCL). Hepatic and splenic perfusion parameters were correlated with HVPG, and sensitivity and specificity for detection of severe portal hypertension (≥12 mmHg) were calculated. The Spearman correlation coefficient was -0.53 (p portal hypertension. • SAF and SCL are statistically significantly correlated with HVPG • SCL showed stronger correlation with HVPG than SAF • 125 ml/min/100 ml SCL-cut-off yielded 94 % sensitivity, 100 % specificity for severe PH • HAF, PVF and HPI showed no statistically significant correlation with HVPG.

  4. Hemodynamic study on liver cirrhosis: clinical application of CT perfusion imaging

    International Nuclear Information System (INIS)

    Jiang Li; Yang Jianyong; Xie Hongbo; Yang Xufeng; Yan Chaogui; Li Ziping; Zeng Fang

    2004-01-01

    Objective: To estimate hepatic perfusion parameters with helical CT, and to study the relationship between hepatic perfusion parameters and the severity of liver cirrhosis. Methods: Dynamic single-section computed tomography (CT) of the liver was performed in 40 participants, including 27 patients with liver cirrhosis and 13 patients without liver disease (control subjects). CT scans were obtained at a single level to include the liver, spleen, aorta, and portal vein. On each CT scan, the attenuation of these organs was measured in regions of interest to provide time-density curves. The arterial, portal venous, and total perfusion of the liver and the hepatic perfusion index were assessed. Results: In the control group, hepatic arterial perfusion, portal venous perfusion, and total hepatic perfusion were (0.2823 ± 0.0969) ml·min -1 ·ml -1 , (1.1788 ± 0.4004) ml·min -1 ·ml -1 , and (1.4563 ± 0.4439) ml·min -1 ·ml -1 , respectively. Hepatic perfusion index was (19.73 ±5.81)%. These hepatic perfusion parameters correlated significantly with the severity of liver cirrhosis. Hepatic arterial perfusion decreased in Child A and B cirrhotic patients [ (0.1685 ± 0.1068) ml·min -1 ·ml -1 and (0.1921 ± 0.0986) ml·min -1 ·ml -1 , respectively]. Comparing to Child A and B cirrhotic patients, hepatic arterial perfusion in Child C cirrhotic patients [(0.3072 · 0.1145) ml·min -1 ·ml -1 ] raised significantly. Portal venous perfusion decreased significantly in Child B and C cirrhotic patients [(0.6331±0.2070) ml·min -1 ·ml -1 and (0.5702 ± 0.3562) ml·min -1 ·ml -1 , respectively]. Total hepatic blood flow reduced markedly in Child B and C cirrhotic patients [(0.8252 ± 0.2952) ml·min -1 ·ml -1 and (0.8774 ± 0.4118) ml·min -1 ·ml -1 , respectively]. Hepatic perfusion index increased in Child C cirrhotic patients (37.48 ± 16.65)%. Conclusion: Dynamic single-section CT showed potential in quantifying hepatic perfusion parameters, and hepatic perfusion

  5. Correlation between melphalan pharmacokinetics and hepatic toxicity following hyperthermic isolated liver perfusion for unresectable metastatic disease.

    Science.gov (United States)

    Mocellin, Simone; Pilati, Pierluigi; Da Pian, Pierpaolo; Forlin, Marco; Corazzina, Susanna; Rossi, Carlo Riccardo; Innocente, Federico; Ori, Carlo; Casara, Dario; Ujka, Francesca; Nitti, Donato; Lise, Mario

    2007-02-01

    In the present work, we report on the results of our pilot study of hyperthermic isolated hepatic perfusion (IHP) with melphalan alone for patients with unresectable metastatic liver tumors refractory to conventional treatments, with particular regard to the correlation between pharmacokinetic findings and hepatic toxicity. Inclusion criteria were unresectable liver metastases, hepatic parenchyma replacement perfusion circuit were assessed by a radiolabeled albumin-based method. Drug concentrations in perfusate and plasma were measured by means of high-performance liquid chromatography (HPLC). Twenty patients with unresectable liver metastases underwent IHP. No intraoperative mortality occurred. Treatment-related systemic toxicity was minimal and reversible. Three patients (15%) experienced grade 4 hepatic toxicity and died due to liver failure and subsequent multiorgan failure. Other six patients had significant (grade 3-4) but transitory hepatic toxicity. Complete and partial responses were observed in three and nine out of 17 evaluable patients, respectively (overall response rate = 70%). The pharmacokinetics study showed a 3% mean perfusate-to-plasma drug leakage (range 1-6%). Logistic regression analysis showed that drug concentration in the perfusate circuit, but not preoperative tests, significantly and independently correlated with hepatic toxicity (P = 0.028). Following melphalan-based IHP, objective tumor regression could be observed in a remarkable percentage of patients refractory to standard treatments. However, hepatic toxicity and related mortality were significant. Our findings suggest that drug dosage personalization based on the measurement of drug distribution volumes might minimize

  6. Effect of hepatic blood flow alteration on the therapeutic effect of cryoablation in VX2 hepatic tumor rabbit: an experimental study

    International Nuclear Information System (INIS)

    Guo Zhi; Ni Hong; Li Baoguo; Hu Yonghua; Xing Wenge; Liu Fang

    2008-01-01

    Objective: To investigate the effect of alteration of blood flow in the hepatic artery on the therapeutic effect of cryoablation in VX2 hepatic tumor rabbit model. Methods: Thirty rabbits with VX2 hepatic tumor were divided into three groups according to hepatic artery blood flow: complete occlusion of the hepatic artery(group A), partial occlusion of the hepatic artery (group B), and no occlusion of the hepatic artery (group C). With conventional CT scan and perfusion scan, the values of blood flow (BF) and blood volume(BV) of VX 2 tumor were computed and the differences among the three groups were analyzed. After cryoablation, the animals were euthanized and the livers were removed. The hepatic tissue from the cryoablation area and surrounding area underwent both methyl thiazolyl tetrazolium (MTY) diaphorase staining and triphenyl tetrazolium chloride (TTC) staining. The gross pathology and histopathological changes were observed. Results: (1)The BF and BV in the three groups were: (7.23 + 2. 15 ) ml·100 g -1 ·min -1 and (1.63±0.52) ml/100 g in group A; (32.65±6.12) ml·100 g -1 ·min -1 and (9.32±2.63) ml/100 g in group B; (61.34±12.15) ml·100 g -1 ·min -1 and (17.51± 3.14) ml/100 g in group C, respectively. There were significant differences among the three groups in the BF and BV (F value was 452.16 and 421.33 in the BF and BV, respectively, P <0.01); (2) The maximum diameter of cryoablation-induced necrosis was (2.3±0.3)cm in group A, (1.5±0.2) cm in group B, and (0.8±0.1) cm in group C, respectively. The difference was significant among the groups (F value was 315.32,P <0.01). (3) There were well-defined frozen areas, bordering areas and normal surrounding areas in MTT staining. In group C, positive staining around some blood vessels could be seen. Conclusion: Alteration of the blood flow in the hepatic artery can affect the cryoablation efficacy. With the decrease of hepatic artery blood flow, the efficacy of cryoablation on liver tumor

  7. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  8. Percutaneous Isolated Hepatic Perfusion for the Treatment of Unresectable Liver Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, Mark C., E-mail: m.c.burgmans@lumc.nl [Leiden University Medical Centre, Department of Radiology (Netherlands); Leede, Eleonora M. de, E-mail: e.m.de-leede@lumc.nl [Leiden University Medical Centre, Department of Surgery (Netherlands); Martini, Christian H., E-mail: c.h.martini@lumc.nl [Leiden University Medical Centre, Department of Anesthesiology (Netherlands); Kapiteijn, Ellen, E-mail: h.w.kapiteijn@lumc.nl [Leiden University Medical Centre, Department of Medical Oncology (Netherlands); Vahrmeijer, Alexander L., E-mail: a.l.vahrmeijer@lumc.nl [Leiden University Medical Centre, Department of Surgery (Netherlands); Erkel, Arian R. van, E-mail: a.r.van-erkel@lumc.nl [Leiden University Medical Centre, Department of Radiology (Netherlands)

    2016-06-15

    Liver malignancies are a major burden of disease worldwide. The long-term prognosis for patients with unresectable tumors remains poor, despite advances in systemic chemotherapy, targeted agents, and minimally invasive therapies such as ablation, chemoembolization, and radioembolization. Thus, the demand for new and better treatments for malignant liver tumors remains high. Surgical isolated hepatic perfusion (IHP) has been shown to be effective in patients with various hepatic malignancies, but is complex, associated with high complication rates and not repeatable. Percutaneous isolated liver perfusion (PHP) is a novel minimally invasive, repeatable, and safer alternative to IHP. PHP is rapidly gaining interest and the number of procedures performed in Europe now exceeds 200. This review discusses the indications, technique and patient management of PHP and provides an overview of the available data.

  9. Percutaneous Isolated Hepatic Perfusion for the Treatment of Unresectable Liver Malignancies

    International Nuclear Information System (INIS)

    Burgmans, Mark C.; Leede, Eleonora M. de; Martini, Christian H.; Kapiteijn, Ellen; Vahrmeijer, Alexander L.; Erkel, Arian R. van

    2016-01-01

    Liver malignancies are a major burden of disease worldwide. The long-term prognosis for patients with unresectable tumors remains poor, despite advances in systemic chemotherapy, targeted agents, and minimally invasive therapies such as ablation, chemoembolization, and radioembolization. Thus, the demand for new and better treatments for malignant liver tumors remains high. Surgical isolated hepatic perfusion (IHP) has been shown to be effective in patients with various hepatic malignancies, but is complex, associated with high complication rates and not repeatable. Percutaneous isolated liver perfusion (PHP) is a novel minimally invasive, repeatable, and safer alternative to IHP. PHP is rapidly gaining interest and the number of procedures performed in Europe now exceeds 200. This review discusses the indications, technique and patient management of PHP and provides an overview of the available data.

  10. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    International Nuclear Information System (INIS)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio; Takeuchi, Yoshihito.

    1998-01-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  11. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio [Aichi Cancer Center, Nagoya (Japan); Takeuchi, Yoshihito

    1998-02-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  12. Spatio-temporal analysis of blood perfusion by imaging photoplethysmography

    Science.gov (United States)

    Zaunseder, Sebastian; Trumpp, Alexander; Ernst, Hannes; Förster, Michael; Malberg, Hagen

    2018-02-01

    Imaging photoplethysmography (iPPG) has attracted much attention over the last years. The vast majority of works focuses on methods to reliably extract the heart rate from videos. Only a few works addressed iPPGs ability to exploit spatio-temporal perfusion pattern to derive further diagnostic statements. This work directs at the spatio-temporal analysis of blood perfusion from videos. We present a novel algorithm that bases on the two-dimensional representation of the blood pulsation (perfusion map). The basic idea behind the proposed algorithm consists of a pairwise estimation of time delays between photoplethysmographic signals of spatially separated regions. The probabilistic approach yields a parameter denoted as perfusion speed. We compare the perfusion speed versus two parameters, which assess the strength of blood pulsation (perfusion strength and signal to noise ratio). Preliminary results using video data with different physiological stimuli (cold pressure test, cold face test) show that all measures are influenced by those stimuli (some of them with statistical certainty). The perfusion speed turned out to be more sensitive than the other measures in some cases. However, our results also show that the intraindividual stability and interindividual comparability of all used measures remain critical points. This work proves the general feasibility of employing the perfusion speed as novel iPPG quantity. Future studies will address open points like the handling of ballistocardiographic effects and will try to deepen the understanding of the predominant physiological mechanisms and their relation to the algorithmic performance.

  13. Liver fat content in type 2 diabetes: relationship with hepatic perfusion and substrate metabolism

    NARCIS (Netherlands)

    Rijzewijk, Luuk J.; van der Meer, Rutger W.; Lubberink, Mark; Lamb, Hildo J.; Romijn, Johannes A.; de Roos, Albert; Twisk, Jos W.; Heine, Robert J.; Lammertsma, Adriaan A.; Smit, Johannes W. A.; Diamant, Michaela

    2010-01-01

    Hepatic steatosis is common in type 2 diabetes. It is causally linked to the features of the metabolic syndrome, liver cirrhosis, and cardiovascular disease. Experimental data have indicated that increased liver fat may impair hepatic perfusion and metabolism. The aim of the current study was to

  14. PulseCam: high-resolution blood perfusion imaging using a camera and a pulse oximeter.

    Science.gov (United States)

    Kumar, Mayank; Suliburk, James; Veeraraghavan, Ashok; Sabharwal, Ashutosh

    2016-08-01

    Measuring blood perfusion is important in medical care as an indicator of injury and disease. However, currently available devices to measure blood perfusion like laser Doppler flowmetry are bulky, expensive, and cumbersome to use. An alternative low-cost and portable camera-based blood perfusion measurement system has recently been proposed, but such camera-only system produces noisy low-resolution blood perfusion maps. In this paper, we propose a new multi-sensor modality, named PulseCam, for measuring blood perfusion by combining a traditional pulse oximeter with a video camera in a unique way to provide low noise and high-resolution blood perfusion maps. Our proposed multi-sensor modality improves per pixel signal to noise ratio of measured perfusion map by up to 3 dB and improves the spatial resolution by 2 - 3 times compared to best known camera-only methods. Blood perfusion measured in the palm using our PulseCam setup during a post-occlusive reactive hyperemia (PORH) test replicates standard PORH response curve measured using laser Doppler flowmetry device but with much lower cost and a portable setup making it suitable for further development as a clinical device.

  15. Effects of lornoxicam and intravenous ibuprofen on erythrocyte deformability and hepatic and renal blood flow in rats.

    Science.gov (United States)

    Arpacı, Hande; Çomu, Faruk Metin; Küçük, Ayşegül; Kösem, Bahadır; Kartal, Seyfi; Şıvgın, Volkan; Turgut, Hüseyin Cihad; Aydın, Muhammed Enes; Koç, Derya Sebile; Arslan, Mustafa

    2016-01-01

    Change in blood supply is held responsible for anesthesia-related abnormal tissue and organ perfusion. Decreased erythrocyte deformability and increased aggregation may be detected after surgery performed under general anesthesia. It was shown that nonsteroidal anti-inflammatory drugs decrease erythrocyte deformability. Lornoxicam and/or intravenous (iv) ibuprofen are commonly preferred analgesic agents for postoperative pain management. In this study, we aimed to investigate the effects of lornoxicam (2 mg/kg, iv) and ibuprofen (30 mg/kg, iv) on erythrocyte deformability, as well as hepatic and renal blood flows, in male rats. Eighteen male Wistar albino rats were randomly divided into three groups as follows: iv lornoxicam-treated group (Group L), iv ibuprofen-treated group (Group İ), and control group (Group C). Drug administration was carried out by the iv route in all groups except Group C. Hepatic and renal blood flows were studied by laser Doppler, and euthanasia was performed via intra-abdominal blood uptake. Erythrocyte deformability was measured using a constant-flow filtrometry system. Lornoxicam and ibuprofen increased the relative resistance, which is an indicator of erythrocyte deformability, of rats (P=0.016). Comparison of the results from Group L and Group I revealed no statistically significant differences (P=0.694), although the erythrocyte deformability levels in Group L and Group I were statistically higher than the results observed in Group C (P=0.018 and P=0.008, respectively). Hepatic and renal blood flows were significantly lower than the same in Group C. We believe that lornoxicam and ibuprofen may lead to functional disorders related to renal and liver tissue perfusion secondary to both decreased blood flow and erythrocyte deformability. Further studies regarding these issues are thought to be essential.

  16. Patient-specific coronary blood supply territories for quantitative perfusion analysis

    Science.gov (United States)

    Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.

    2018-01-01

    Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098

  17. Association Between MC-2 Peptide and Hepatic Perfusion and Liver Injury Following Resuscitated Hemorrhagic Shock.

    Science.gov (United States)

    Matheson, Paul J; Fernandez-Botran, Rafael; Smith, Jason W; Matheson, Samuel A; Downard, Cynthia D; McClain, Craig J; Garrison, Richard N

    2016-03-01

    Hemorrhagic shock (HS) due to trauma remains a major cause of morbidity and mortality in the United States, despite continuing progression of advanced life support and treatment. Trauma is the third most common cause of death worldwide and is the leading cause of death in the 1- to 44-year-old age group. Hemorrhagic shock often progresses to multiple organ failure despite conventional resuscitation (CR) that restores central hemodynamics. To examine whether MC-2 would bind glycosaminoglycans to decrease proinflammatory cytokines' influence in the liver, minimize organ edema, prevent liver injury, and improve hepatic perfusion. MC-2, a synthetic octapeptide derived from the heparin-binding domain of murine interferon gamma (IFN-γ), binds glycosaminoglycans to modulate serum and interstitial cytokine levels and activity. A controlled laboratory study of 3y male Sprague-Dawley rats that were randomized to 4 groups of 8 each: sham, sham+MC-2 (50 mg/kg), HS/CR, or HS/CR+MC-2 (HS = 40% of baseline mean arterial pressure for 60 minutes; CR = return of shed blood and 2 volumes of saline). The study began in March, 2013. Effective hepatic blood flow (EHBF) by galactose clearance, wet-dry weights, cytokines, histopathology, complete metabolic panel, and complete blood cell count were performed at 4 hours after CR. MC-2 partially reversed the HS/CR-induced hepatic hypoperfusion at 3 and 4 hours postresuscitation compared with HS/CR alone. Effective hepatic blood flow decreased during the HS period from a mean (SD) of 7.4 (0.3) mL/min/100 g and 7.5 (0.5) mL/min/100g at baseline to 3.7 (0.4) mL/min/100g and 5.9 (0.5) mL/min/100g for the HS/CR and HS/CR+MC-2 groups, respectively (P hepatic blood flow remained constant in the sham groups throughout the experimental protocol. Organ edema was increased in the ileum and liver in the HS/CR vs sham group, and MC-2 decreased edema in the ileum vs the HS/CR group. MC-2 in HS also decreased levels of alanine aminotransferase

  18. Disposition kinetics of diclofenac in the dual perfused rat liver.

    Science.gov (United States)

    Sahin, Selma; Rowland, Malcolm

    2013-09-01

    This study investigates the hepatic disposition of diclofenac as a function of route of input: portal vein (PV) versus hepatic artery (HA) in the presence of its binding protein, albumin. The in situ dual perfused rat liver was performed using Krebs bicarbonate buffer containing human serum albumin (HSA, 0.25%-1%) at constant PV (12 mL/min) and HA (3 mL/min) flow rates. Bolus doses of [(14) C]-diclofenac and (125) I-labeled HSA were injected randomly into the HA or PV and then, after an appropriate interval, into the alternate vessel. Regardless of route of input and perfusion medium protein concentration, the hepatic outflow profile of diclofenac displayed a characteristic sharp peak followed by a slower eluting tail, indicating that its radial distribution is not instantaneous. Based on the estimated effective permeability-surface area product/blood flow ratio, hepatic uptake of diclofenac is governed by both perfusion and permeability. Fractional effluent recovery (F) increased as unbound diclofenac fraction in the perfusate decreased. Although no significant difference in hepatic clearance of diclofenac as a function of route of delivery at 0.5% and 1% HSA, it was demonstrable at 0.25% HSA (p < 0.001), when the extraction ratio is higher. Copyright © 2013 Wiley Periodicals, Inc.

  19. The correlation of CT perfusion imaging with microvessel density and vascular endothelial growth factor in hepatic alveolar echinococcosis

    International Nuclear Information System (INIS)

    Wang Jing; Ren Bo; Liu Wenya; Wen Hao; Qing Song; Xie Weidong; Sun Yajing; Wang Haitao

    2011-01-01

    Objective: To explore the correlation of CT perfusion imaging with microvessel density (MVD) and vascular endothelial growth factor (VEGF) in hepatic alveolar echinococcosis (HAE). Methods: Multi-slice spiral CT perfusion imaging was performed in 27 patients with HAE. Time-density curves(TDC) of the HAE peripheral area was drawn from the region of interest (ROI) with perfusion functional software. CT perfusion parameters including blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were calculated. MVD and VEGF expression of pathological specimens were examined by immunohistochemical staining with anti-CD34, anti-VEGF monoclonal antibody. The CT perfusion parameters, MVD and VEGF were compared in different types of TDC with t test. The correlation of CT perfusion parameters with MVD and VEGF were analyzed with Spearman test. Results: In this group, 21 cases which TDC lower than that of the liver were classified as type Ⅰ, the others 6 cases TDC higher than the liver were of type Ⅱ TDC. TDC perfusion parameters of the two types were as follows, BF: (111.7±27.6), (158.9±39.5) ml · 100 g -1 · min -1 , BV: (15.1±6.2) , (26.8±8.4) ml/100 g, MTT: (7.0±4.4), (7.7±3.1) s, PS: (51.7±17.3), (51.0±20.5) ml ·100 g -1 · min -1 . The significant differences of BF, BV and MVD [(20.5±5.4)/HP, (37.2±7.5)/HP, respectively] were found between two types (t=-7.897, -18.783, -5.223, P 0.05). The correlation was found between the MVD and BF and BV in the type Ⅱ TDC group (r=0.789 and 0.878, respectively) and no correlation was found between MVD and each CT perfusion parameters in the type Ⅰ TDC group (P>0.05). There was no correlation between the VEGF expression and CT perfusion parameters in two types of TDC (P>0.05). Conclusion: CT perfusion imaging with different type of TDC reflected different situation of angiogenesis in HAE peripheral area, which could be a potential technique to illustrate the

  20. Skin Blood Perfusion and Oxygenation Colour Affect Perceived Human Health

    Science.gov (United States)

    Stephen, Ian D.; Coetzee, Vinet; Law Smith, Miriam; Perrett, David I.

    2009-01-01

    Skin blood perfusion and oxygenation depends upon cardiovascular, hormonal and circulatory health in humans and provides socio-sexual signals of underlying physiology, dominance and reproductive status in some primates. We allowed participants to manipulate colour calibrated facial photographs along empirically-measured oxygenated and deoxygenated blood colour axes both separately and simultaneously, to optimise healthy appearance. Participants increased skin blood colour, particularly oxygenated, above basal levels to optimise healthy appearance. We show, therefore, that skin blood perfusion and oxygenation influence perceived health in a way that may be important to mate choice. PMID:19337378

  1. Blood temperature and perfusion to exercising and non-exercising human limbs.

    Science.gov (United States)

    González-Alonso, José; Calbet, José A L; Boushel, Robert; Helge, Jørn W; Søndergaard, Hans; Munch-Andersen, Thor; van Hall, Gerrit; Mortensen, Stefan P; Secher, Niels H

    2015-10-01

    What is the central question of this study? Temperature-sensitive mechanisms are thought to contribute to blood-flow regulation, but the relationship between exercising and non-exercising limb perfusion and blood temperature is not established. What is the main finding and its importance? The close coupling among perfusion, blood temperature and aerobic metabolism in exercising and non-exercising extremities across different exercise modalities and activity levels and the tight association between limb vasodilatation and increases in plasma ATP suggest that both temperature- and metabolism-sensitive mechanisms are important for the control of human limb perfusion, possibly by activating ATP release from the erythrocytes. Temperature-sensitive mechanisms may contribute to blood-flow regulation, but the influence of temperature on perfusion to exercising and non-exercising human limbs is not established. Blood temperature (TB ), blood flow and oxygen uptake (V̇O2) in the legs and arms were measured in 16 healthy humans during 90 min of leg and arm exercise and during exhaustive incremental leg or arm exercise. During prolonged exercise, leg blood flow (LBF) was fourfold higher than arm blood flow (ABF) in association with higher TB and limb V̇O2. Leg and arm vascular conductance during exercise compared with rest was related closely to TB (r(2) = 0.91; P exercise, LBF increased in association with elevations in TB and limb V̇O2, whereas ABF, arm TB and V̇O2 remained largely unchanged. During incremental arm exercise, both ABF and LBF increased in relationship to similar increases in V̇O2. In 12 trained males, increases in femoral TB and LBF during incremental leg exercise were mirrored by similar pulmonary artery TB and cardiac output dynamics, suggesting that processes in active limbs dominate central temperature and perfusion responses. The present data reveal a close coupling among perfusion, TB and aerobic metabolism in exercising and non

  2. Blood perfusion and pH monitoring in organs by laser-induced fluorescence spectroscopy

    Science.gov (United States)

    Vari, Sandor G.; Papazoglou, Theodore G.; Pergadia, Vani R.; Stavridi, Marigo; Snyder, Wendy J.; Papaioannou, Thanassis; Duffy, J. T.; Weiss, Andrew B.; Thomas, Reem; Grundfest, Warren S.

    1994-01-01

    Sensitivity of laser-induced fluorescence spectroscopy (LIFS) in detecting a change in tissue pH, and blood perfusion was determined. Rabbits were anesthetized, paralyzed, and mechanically ventilated. The arterial and venous blood supplies of the kidney were isolated and ligated to alter the perfusion. The femoral artery was cannulated to extract samples for blood gas analysis. A 308-nm XeCl was used as an excitation source. A 600 micrometers core diameter fiber was used for fluorescence acquisition, and the spectra analyzed by an optical multichannel analyzer (EG & G, OMA III). the corresponding intensity ratio R equals INADH / ICOLL was used as an index for respiratory acidosis. Blood perfusion was assessed using the following algorithm: (IELAS minus ICOLL) divided by (INADH minus ICOLL). The intensity ratio linearly decreased with the reduction of blood perfusion. When we totally occluded the artery the ratio decreased tenfold when compared to the ratio of a fully perfused kidney. Results of monitoring blood acidosis by laser-induced fluorescence spectroscopy shows a significant trend between pH and intensity ratio. Since all the slopes were negative, there is an obvious significant correlation between the pH and NADH.COLLAGEN RATIO. Blue-light-induced fluorescence measurements and ratio fluorometry is a sensitive method for monitoring blood perfusion and acidity or alkalinity of an organ.

  3. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... is a valid method for assessing macular perfusion. Results were consistent with previous observations of hyperoxic blood flow reduction using blue field entoptic and laser Doppler velocimetry. Retinal perfusion seemed to be regulated around individual set points according to blood glucose levels. Multimodal...

  4. Chemosaturation with Percutaneous Hepatic Perfusion for Unresectable Isolated Hepatic Metastases from Sarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Deneve, Jeremiah L., E-mail: Jeremiah.Deneve@Moffitt.org [Moffitt Cancer Center, Department of Cutaneous and Sarcoma Oncology (United States); Choi, Junsung [Moffitt Cancer Center, Department of Interventional Radiology (United States); Gonzalez, Ricardo J.; Conley, Anthony P.; Stewart, Steven; Han, Dale [Moffitt Cancer Center, Department of Cutaneous and Sarcoma Oncology (United States); Werner, Philip; Chaudhry, Tariq A. [Moffitt Cancer Center, Department of Anesthesia (United States); Zager, Jonathan S., E-mail: Jonathan.Zager@Moffitt.org [Moffitt Cancer Center, Department of Cutaneous and Sarcoma Oncology (United States)

    2012-12-15

    Purpose: Treatment of patients with unresectable liver metastases is challenging. Regional therapies to the liver have been developed that maximize treatment of the localized disease process without systemic toxic adverse effects. We discuss the procedural aspects of liver chemosaturation with percutaneous hepatic perfusion (CS-PHP). Methods: We present as an illustration of this technique a case report of the treatment of unresectable metastatic leiomyosarcoma of the liver. Results: A randomized phase III trial for unresectable liver metastases from melanoma was recently completed comparing CS-PHP with melphalan vs. best alternative care (BAC). When compared with BAC, CS-PHP was associated with a significant improvement in hepatic progression-free survival (8.0 months CS-PHP vs. 1.6 months BAC, p < 0.0001) and overall progression-free survival (6.7 months CS-PHP vs. 1.6 months BAC, p < 0.0001), respectively. On the basis of these results, and given our experience as one of the treating institutions for this phase III trial, we appealed for compassionate use of CS-PHP in a patient with isolated bilobar unresectable hepatic metastases from leiomyosarcoma. Four target lesions were identified and monitored to assess treatment response. A total of 4 CS-PHP procedures were performed, with a 25 % reduction in size of the largest lesion observed and 16 month hepatic progression-free survival. Toxicity was mild (neutropenia) and manageable on an outpatient basis. Conclusion: CS-PHP offers several advantages for unresectable hepatic sarcoma metastases. CS-PHP is minimally invasive and repeatable, and it has a predictable and manageable systemic toxicity profile. For appropriately selected patients, CS-PHP can delay tumor progression and could potentially improve survival.

  5. Chemosaturation with Percutaneous Hepatic Perfusion for Unresectable Isolated Hepatic Metastases from Sarcoma

    International Nuclear Information System (INIS)

    Deneve, Jeremiah L.; Choi, Junsung; Gonzalez, Ricardo J.; Conley, Anthony P.; Stewart, Steven; Han, Dale; Werner, Philip; Chaudhry, Tariq A.; Zager, Jonathan S.

    2012-01-01

    Purpose: Treatment of patients with unresectable liver metastases is challenging. Regional therapies to the liver have been developed that maximize treatment of the localized disease process without systemic toxic adverse effects. We discuss the procedural aspects of liver chemosaturation with percutaneous hepatic perfusion (CS-PHP). Methods: We present as an illustration of this technique a case report of the treatment of unresectable metastatic leiomyosarcoma of the liver. Results: A randomized phase III trial for unresectable liver metastases from melanoma was recently completed comparing CS-PHP with melphalan vs. best alternative care (BAC). When compared with BAC, CS-PHP was associated with a significant improvement in hepatic progression-free survival (8.0 months CS-PHP vs. 1.6 months BAC, p < 0.0001) and overall progression-free survival (6.7 months CS-PHP vs. 1.6 months BAC, p < 0.0001), respectively. On the basis of these results, and given our experience as one of the treating institutions for this phase III trial, we appealed for compassionate use of CS-PHP in a patient with isolated bilobar unresectable hepatic metastases from leiomyosarcoma. Four target lesions were identified and monitored to assess treatment response. A total of 4 CS-PHP procedures were performed, with a 25 % reduction in size of the largest lesion observed and 16 month hepatic progression-free survival. Toxicity was mild (neutropenia) and manageable on an outpatient basis. Conclusion: CS-PHP offers several advantages for unresectable hepatic sarcoma metastases. CS-PHP is minimally invasive and repeatable, and it has a predictable and manageable systemic toxicity profile. For appropriately selected patients, CS-PHP can delay tumor progression and could potentially improve survival.

  6. Tissue hepatic blood volume and liver function

    International Nuclear Information System (INIS)

    Masuyama, Mamoru

    1997-01-01

    Positron emission tomography (PET) scan has an advantage that it can measure regional organ blood flow and volume not only quantitatively but also non-invasively. In order to estimate the liver function, tissue hepatic blood volume was measured using C 15 O inhalation in conjunction with positron emission tomography. PET scans of the liver were performed after the single breath inhalation of 20 mCi of high specific activity 15 O-labeled carbon monoxide in 105 patients which were classified 3 groups; normal, chronic hepatitis, and cirrhosis. They consist of 61, 14, and 30 patients, respectively. Significant differences between normal and cirrhotic patients were noted in tissue hepatic blood volume (mean 20.4, 18.2, 16.0 ml/100 g, respectively). Tissue hepatic blood volume (tHBV) correlated with the reaction of the peripheral reticuloendothelial compartment and protein synthesis, because there was a potent correlation between tHBV and hepatic fibrosis. In normal livers, we were able to demonstrate significant differences in tissue hepatic blood volume among liver segments. (author)

  7. Blood lipids analysis in patients with hepatitis and hepatic fibrosis

    International Nuclear Information System (INIS)

    Si Jianhong

    2007-01-01

    Objective: To investigate the correlationship between blood hepatic fibrosis markers and blood lipids levels. Methods: Serum hepatic fibrosis markers (HA, PC III, IV-C, LN) levels were determined with RIA and serum lipids (TG, TCh HDL; LDL, apoA1, apoB) were measured with biochemical methods in 98 patients with hepatitis in various stages and 50 controls. Liver biopsy was done in all the hepatitis patients. Results: Hepatic fibrosis was classified into 5 grades (S0-S4) according to the pathology shown in the biopsy specimen. The serum lipid levels decreased along with the increase of severity of fibrosis from S0 to S4. Levels in S4 patients were significantly lower than those in controls (P 0.05). Conclusion: The serum hepatic fibrosis markers levels increased and lipids levels decreased along with the progress of hepatitis from acute to cirrhosis. (authors)

  8. Blood temperature and perfusion to exercising and non‐exercising human limbs

    Science.gov (United States)

    Calbet, José A. L.; Boushel, Robert; Helge, Jørn W.; Søndergaard, Hans; Munch‐Andersen, Thor; van Hall, Gerrit; Mortensen, Stefan P.; Secher, Niels H.

    2015-01-01

    New Findings What is the central question of this study? Temperature‐sensitive mechanisms are thought to contribute to blood‐flow regulation, but the relationship between exercising and non‐exercising limb perfusion and blood temperature is not established. What is the main finding and its importance? The close coupling among perfusion, blood temperature and aerobic metabolism in exercising and non‐exercising extremities across different exercise modalities and activity levels and the tight association between limb vasodilatation and increases in plasma ATP suggest that both temperature‐ and metabolism‐sensitive mechanisms are important for the control of human limb perfusion, possibly by activating ATP release from the erythrocytes. Temperature‐sensitive mechanisms may contribute to blood‐flow regulation, but the influence of temperature on perfusion to exercising and non‐exercising human limbs is not established. Blood temperature (T B), blood flow and oxygen uptake (V˙O2) in the legs and arms were measured in 16 healthy humans during 90 min of leg and arm exercise and during exhaustive incremental leg or arm exercise. During prolonged exercise, leg blood flow (LBF) was fourfold higher than arm blood flow (ABF) in association with higher T B and limb V˙O2. Leg and arm vascular conductance during exercise compared with rest was related closely to T B (r 2 = 0.91; P exercise, LBF increased in association with elevations in T B and limb V˙O2, whereas ABF, arm T B and V˙O2 remained largely unchanged. During incremental arm exercise, both ABF and LBF increased in relationship to similar increases in V˙O2. In 12 trained males, increases in femoral T B and LBF during incremental leg exercise were mirrored by similar pulmonary artery T B and cardiac output dynamics, suggesting that processes in active limbs dominate central temperature and perfusion responses. The present data reveal a close coupling among perfusion, T B and aerobic metabolism

  9. Captopril improves tumor nanomedicine delivery by increasing tumor blood perfusion and enlarging endothelial gaps in tumor blood vessels.

    Science.gov (United States)

    Zhang, Bo; Jiang, Ting; Tuo, Yanyan; Jin, Kai; Luo, Zimiao; Shi, Wei; Mei, Heng; Hu, Yu; Pang, Zhiqing; Jiang, Xinguo

    2017-12-01

    Poor tumor perfusion and unfavorable vessel permeability compromise nanomedicine drug delivery to tumors. Captopril dilates blood vessels, reducing blood pressure clinically and bradykinin, as the downstream signaling moiety of captopril, is capable of dilating blood vessels and effectively increasing vessel permeability. The hypothesis behind this study was that captopril can dilate tumor blood vessels, improving tumor perfusion and simultaneously enlarge the endothelial gaps of tumor vessels, therefore enhancing nanomedicine drug delivery for tumor therapy. Using the U87 tumor xenograft with abundant blood vessels as the tumor model, tumor perfusion experiments were carried out using laser Doppler imaging and lectin-labeling experiments. A single treatment of captopril at a dose of 100 mg/kg significantly increased the percentage of functional vessels in tumor tissues and improved tumor blood perfusion. Scanning electron microscopy of tumor vessels also indicated that the endothelial gaps of tumor vessels were enlarged after captopril treatment. Immunofluorescence-staining of tumor slices demonstrated that captopril significantly increased bradykinin expression, possibly explaining tumor perfusion improvements and endothelial gap enlargement. Additionally, imaging in vivo, imaging ex vivo and nanoparticle distribution in tumor slices indicated that after a single treatment with captopril, the accumulation of 115-nm nanoparticles in tumors had increased 2.81-fold with a more homogeneous distribution pattern in comparison to non-captopril treated controls. Finally, pharmacodynamics experiments demonstrated that captopril combined with paclitaxel-loaded nanoparticles resulted in the greatest tumor shrinkage and the most extensive necrosis in tumor tissues among all treatment groups. Taken together, the data from the present study suggest a novel strategy for improving tumor perfusion and enlarging blood vessel permeability simultaneously in order to improve

  10. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  11. Esophageal blood flow in the cat. Normal distribution and effects of acid perfusion

    International Nuclear Information System (INIS)

    Hollwarth, M.E.; Smith, M.; Kvietys, P.R.; Granger, D.N.

    1986-01-01

    The radioactive microsphere technique was used to estimate blood flow to different regions of the esophagus and to adjacent regions of the stomach before and after perfusion of the esophagus with hydrochloric acid (pH 1.5) for 5 min. Under resting conditions total blood flow, as well as blood flow to the mucosal-submucosal layer and the muscular layer, to both sphincters was significantly higher than to the esophageal body. Blood flow to the adjacent regions of the stomach was significantly higher than esophageal blood flow. Acid perfusion resulted in a large increase in total blood flow in both sphincters and the lower esophageal body. Gastric blood flow was not altered by acid perfusion. The esophageal hyperemia resulted primarily from an increase in blood flow to the muscular layer; mucosal-submucosal blood flow was increased only in the lower esophageal sphincter. The present study indicates that short periods (5 min) of gastroesophageal reflux may increase esophageal blood flow

  12. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  13. Finite-element simulation of blood perfusion in muscle tissue during compression and sustained contraction.

    Science.gov (United States)

    Vankan, W J; Huyghe, J M; Slaaf, D W; van Donkelaar, C C; Drost, M R; Janssen, J D; Huson, A

    1997-09-01

    Mechanical interaction between tissue stress and blood perfusion in skeletal muscles plays an important role in blood flow impediment during sustained contraction. The exact mechanism of this interaction is not clear, and experimental investigation of this mechanism is difficult. We developed a finite-element model of the mechanical behavior of blood-perfused muscle tissue, which accounts for mechanical blood-tissue interaction in maximally vasodilated vasculature. Verification of the model was performed by comparing finite-element results of blood pressure and flow with experimental measurements in a muscle that is subject to well-controlled mechanical loading conditions. In addition, we performed simulations of blood perfusion during tetanic, isometric contraction and maximal vasodilation in a simplified, two-dimensional finite-element model of a rat calf muscle. A vascular waterfall in the venous compartment was identified as the main cause for blood flow impediment both in the experiment and in the finite-element simulations. The validated finite-element model offers possibilities for detailed analysis of blood perfusion in three-dimensional muscle models under complicated loading conditions.

  14. Recruitment of neutrophils across the blood-brain barrier: the role of posttraumatic hepatic ischemia

    Directory of Open Access Journals (Sweden)

    Mantovani Mario

    2003-01-01

    Full Text Available PURPOSE: To study the effects of total hepatic ischemia, and reperfusion on the accumulation of neutrophils in the brain of rats submitted to normovolemic conditions as well as to controlled hemorrhagic shock state. METHODS: Thirty two adult male Wistar rats, were divided into four groups: the Control group, was submitted to the standard procedures for a period of 60 min of observation; Shock group, was submitted to controlled hemorrhagic shock (mean arterial blood pressure=40mmHg, 20min followed by volemic resuscitation (lactated Ringer's solution + blood, 3:1 and reperfusion for 60min; Pringle group, was submitted to total hepatic ischemia for 15min and reperfusion for 60min. The total group was submitted to controlled hemorrhagic shock for 20min followed by volemic resuscitation (lactated Ringer's solution + blood, 3:1, total hepatic ischemia for 15min and reperfusion for 60min. Measurements of serum lactate and base excess were used to characterize the hemorrhagic shock state with low tissue perfusion. The counting of neutrophils on the brain was performed after the euthanasia of animals. RESULTS: The values for the counting of neutrophils on the brain indicate that did not occur difference among studied groups (p=0.196 (Control 0.12± 0.11, Shock 0.12± 0.13, Pringle 0.02± 0.04, Total 0.14± 0.16. CONCLUSION: Hemorrhagic shock associated to total hepatic ischemia for 15 minutes, followed by 60 minutes of reperfusion, did not causes significant neutrophils accumulation in the brain of rats.

  15. Functional assessment of the hepatic arterial blood flow by pharmacoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Stellamor, K; Hruby, W; Peschl, L

    1981-12-01

    By means of celiacography it was possible to demonstrate that parenteral medication with parathormone creates a selective dilatation of the liver vessels in man, provided that they are dilatable. This hemodynamic hormone effect could not be traced in the other mesenteric vessels. The increase of portal hypertension resulting from cirrhosis leads to a loss of the dilating ability of liver vessels. This regressive reaction is well demonstrated on the parathormone-celiacogram. Thus a functional assessment of the hepatic blood flow is possible. The extent of the dilatability of the liver artery seems to be of great importance for the prognosis and indication of the porto-systemic shunt-operation. Moreover we could show that an increase in the liver perfusion demonstrates pathologic liver processes in a better way.

  16. Non-invasive monitoring of muscle blood perfusion by photoplethysmography: evaluation of a new application.

    Science.gov (United States)

    Sandberg, M; Zhang, Q; Styf, J; Gerdle, B; Lindberg, L-G

    2005-04-01

    To evaluate a specially developed photoplethysmographic (PPG) technique, using green and near-infrared light sources, for simultaneous non-invasive monitoring of skin and muscle perfusion. Evaluation was based on assessments of changes in blood perfusion to various provocations, such as post-exercise hyperaemia and hyperaemia following the application of liniment. The deep penetrating feature of PPG was investigated by measurement of optical radiation inside the muscle. Simultaneous measurements using ultrasound Doppler and the new PPG application were performed to elucidate differences between the two methods. Specific problems related to the influence of skin temperature on blood flow were highlightened, as well. Following static and dynamic contractions an immediate increase in muscle perfusion was shown, without increase in skin perfusion. Liniment application to the skin induced a rapid increase in skin perfusion, but not in muscle. Both similarities and differences in blood flow measured by Ultrasound Doppler and PPG were demonstrated. The radiant power measured inside the muscle, by use of an optical fibre, showed that the near-infrared light penetrates down to the vascular depth inside the muscle. The results of this study indicate the potentiality of the method for non-invasive measurement of local muscle perfusion, although some considerations still have to be accounted for, such as influence of temperature on blood perfusion.

  17. The value of multi-slice spiral CT liver perfusion imaging to evaluate the chronic hepatic fibrosis and cirrhosis

    International Nuclear Information System (INIS)

    Long Liling; Huang Zhongkui; Ding Ke; Liao Jinyuan; Jiang Jianning

    2012-01-01

    Objective: To investigate the value of the MSCT liver perfusion imaging parameters in the evaluation of the chronic hepatic fibrosis and cirrhosis. Methods: Liver CT perfusion (CTP) was performed in 107 participants,including 31 patients with mild hepatic fibrosis (S1, S2), 34 patients with severe hepatic fibrosis (S3, S4) and early stage of hepatic cirrhosis which conformed by liver pathologic biopsy, 42 patients with hepatic cirrhosis who had typical clinical and image signs, and 30 healthy subjects as control group. The data of CTP (HAP, PVP, LTP, HPI and TTP) at different stages were obtained with Body perfect CT-syngo CT2007A and control study with histopathologic stage. Compared the study index by the one-way ANOVA analysis. Used Spearman rank correlation to analysis the relationship between liver perfusion imaging parameters and the degrees of the chronic hepatic fibrosis. Used Logistic regression to analysis the maximum regression coefficient among the liver perfusion imaging parameters, which affected the histopathologic stage mostly. Results: In the subgroups of the chronic hepatic fibrosis S1, S2, S3, S4 to the hepatic cirrhosis,HAP values was (28.9 ±8.6), (24.6 ±2.4), (29.2 ±2.3) and (38.9 ± 7.0) ml · 100 ml -1 · min -1 , respectively. HAP decreased firstly,then increased. Statistic analysis showed the difference of HAP between later-stage cirrhosis and other groups (F=40.26, P<0.01). PVP values of above subgroups was (111.3 ± 18.1), (92.9 ±5.3), (73.0 ±9.0) and (54.1 ± 13.8) ml · 100 ml -1 ·min -1 , respectively. TLP values of above subgroups was (140.2 ± 25.9), (117.1 ± 4.5), (102.3 ± 8.7)and (93.0 ± 11.8) ml · 100 ml -1 ·min -1 , respectively. The difference of PVP, TLP among each subgroup was significant (F=136.79, 67.40, respectively, P<0.01). HPI values of above subgroups was (20.4 ± 2.6)%, (21.0 ±2.1)%, (28.5 ±3.1)% and (42.6± 11.1)%, respectively. TTP values of above subgroups was (123.7±22.2), (137.1 ±27.1), (145.0 ±28

  18. Relations between CT perfusion parameters and degree of hepatic ischemia reperfusion injury in a rabbit model

    International Nuclear Information System (INIS)

    Guo Chengwei; Shen Sandi; Yi Xianlin; Zhang Zhonglin; Liu Zaiyi; Liang Changhong

    2011-01-01

    Objective: To observe the changes of hepatic CT perfusion parameters and their correlation with serum aspartate transaminase (AST), alanine transaminase (ALT) and alkaline phosphatase (ALP) in a rabbit hepatic ischemia reperfusion injury (IRI) model. Methods: Hepatic IRI was produced in rabbits by inducing left liver lobe ischemia (60 min) followed by 6 h, 12 h and 24 h reperfusion (6 rabbits were used for each reperfusion interval). Additional 6 rabbits were served as sham-operated controls. All the rabbits were scanned with a dynamic iCT protocol. Blood samples were taken from the superior mesenteric vein to measure the levels of serum amylase (ALT, AST, and ALP) in various groups, and liver samples were taken for histological examinations after scanning. One-way analysis of variance (ANOVA) was used to determine differences between groups. The correlations of CT perfusion parameters with serum levels were analyzed using Pearson correlation coefficient. Results: Heterogeneity of CT perfusion patterns appeared in the 6 h groups, which presented as low enhanced area [(25.1±9.3) ml · min -1 · 100 mg -1 ]. In reduced perfusion regions of IRI group, HAP of 12 h IRI group [(19.5± 13.6) ml · min -1 · 100 mg -1 ], 24 h IRI group (8.0±2.7) ml · min -1 · 100 mg -1 ], HPP of 6 h IRI group [(10.8±5.5) ml · min -1 · 100 mg -1 ], 12 h IRI group [(14.4±5.2) ml · min -1 · 100 mg -1 ] , 24 h IRI group [(7.8±3.3) ml · min -1 · 100 mg -1 ] and TLP of 6 h IRI group [(35.9±14.0) ml · min -1 · 100 mg -1 ], 12 h IRI group [(33.9±16.1) ml · min -1 · 100 mg -1 ], 24 h IRI group [(16.0± 5.5) ml · min -1 · 100 mg -1 ] were lower than those of sham group [HAP (21.2±10.5) ml · min -1 · 100 mg -1 , HPP (63.5±24.0) ml · min -1 · 100 mg -1 , TLP (81.4±24.8) ml · min -1 · 100 mg -1 ] (F=8.376, 25.950, 16.925, P<0.01). However, HPI of 6 h IRI group [(65.9±3.9)%], 12 h IRI group [(54.2±16.7)%], and 24 h IRI group [(48.9±10.0)%] were higher compared to sham

  19. Multiple-indicator dilution technique for characterization of normal and retrograde flow in once-through rat liver perfusions

    International Nuclear Information System (INIS)

    St-Pierre, M.V.; Schwab, A.J.; Goresky, C.A.; Lee, W.F.; Pang, K.S.

    1989-01-01

    The technique of normal and retrograde rat liver perfusion has been widely used to probe zonal differences in drug-metabolizing activities. The validity of this approach mandates the same tissue spaces being accessed by substrates during both normal and retrograde perfusions. Using the multiple-indicator dilution technique, we presently examine the extent to which retrograde perfusion alters the spaces accessible to noneliminated references. A bolus dose of 51Cr-labeled red blood cells, 125I-albumin, 14C-sucrose and 3H2O was injected into the portal (normal) or hepatic (retrograde) vein of rat livers perfused at 10 ml per min per liver. The outflow perfusate was serially collected over 220 sec to characterize the transit times and the distribution spaces of the labels. During retrograde perfusion, red blood cells, albumin and sucrose profiles peaked later and lower than during normal perfusion, whereas the water curves were similar. The transit times of red blood cells, albumin and sucrose were longer (p less than 0.005), whereas those for water did not change. Consequently, retrograde flow resulted in significantly larger sinusoidal blood volumes (45%), albumin Disse space (42%) and sucrose Disse space (25%) than during normal flow, whereas the distribution spaces for total and intracellular water remained unaltered. The distension of the vascular tree was confirmed by electron microscopy, by which occasional isolated foci of widened intercellular recesses and spaces of Disse were observed. Cellular ultrastructure was otherwise unchanged, and there was no difference found between normal and retrograde perfusion for bile flow rates, AST release, perfusion pressure, oxygen consumption and metabolic removal of ethanol, a substrate with flow-limited distribution, which equilibrates rapidly with cell water (hepatic extraction ratios were virtually identical: normal vs. retrograde, 0.50 vs. 0.48 at 6 to 7.4 mM input concentration)

  20. Evaluation of hepatic blood flow using 99mTc-GSA in rats with hepatic blood flow manipulation

    International Nuclear Information System (INIS)

    Hiraguchi, Etsuo

    1995-01-01

    Blood clearance and hepatic uptake parameters of 99m Tc-DTPA-galactosyl human serum albumin ( 99m Tc-GSA) were evaluated in two groups of rats, normal liver group and CCl 4 induced chronic liver injury group. In each group, four subgroups were classified as follows: simple laparotomy (LAP), hepatic artery ligation (HAL), portal vein ligation (PVL) and both hepatic artery and portal vein ligation (HAL+PVL). 99m Tc-GSA was intravenously injected (50 μg/100 g B.W.) to rats. Heart and liver were targetted as region of interest and time activity curves (TACs) were obtained. The blood clearance parameters (HH4 and Kd) and the hepatic uptake parameters (LHL4 and Ku) were calculated from these TACs. In normal liver group, the mean HH4 of LAP was significantly different from those of PVL and HAL+PVL. Similarly, the other three parameters (LHL4, Kd and Ku) of LAP were significantly different from those of PVL and HAL+PVL. CCl 4 induced chronic liver injury group showed significant difference on all four parameters in four subgroups. Hepatic tissue blood flow rates (HTBFR) calculated by Laser Doppler flowmeter correlated well with 99m Tc-GSA parameters in both groups. These results suggest that 99m Tc-GSA is useful to estimate hepatic blood flow not only in rats with normal liver, but also in rats with CCl 4 induced chronic liver injury. (author)

  1. Exercise induced pulmonary, hepatic and splenic blood volume changes in diabetic subjects

    International Nuclear Information System (INIS)

    Mubashar, M.

    1993-01-01

    Exercise induced blood volume changes in visceral organs were determined by scintillation gamma camera imaging in 11 normal healthy male volunteers and 15 NIDDM male diabetics without clinical signs of neuropathy. After in-vivo labelling of red cells with Technetium-99m, the data was acquired in the supine position at rest and immediately after graded upright ergometer bicycle exercise. From rest to peak exercise, pulmonary blood volume increased 19% and 75% in normal volunteers of less than and more than 40 years of age respectively. A decrease of 18% and 42% was noted in the hepatic and splenic blood volume respectively, regardless of the age, in the normal subjects. In contrast to normals, the diabetic patients showed in response to peak exercise as compared to age-matched controls. A significant difference in the drop in pulmonary blood volume 82.37% and 90% was observed between diabetics of more than and less than 7 years duration respectively. The liver and spleen of the diabetic subjects revealed a lesser decrease of 87.6% and 71.33% respectively in response to peak stress in comparison to the age matched controls. The reduction in the hepatic and splenic blood volume was equally evident in diabetics of more than or less than 50 years of age and it was statistically nonsignificant. This study demonstrates that the normal pattern of redistribution of blood volume in response to maximum exercise in diabetics is altered such that there is restricted pulmonary perfusion and diminished vasoconstriction of the hepato splenic vascular bed and the changes in the pulmonary circulation are related to the duration of the diabetics rather than the age of the patient. (author)

  2. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  3. The Blood Disappearance Rate of 198Au-Colloid and Changes of Hepatic Blood Flow During Position Change in Normal Persons and in Patients with Various Hepatic Diseases

    International Nuclear Information System (INIS)

    Cho, Bo Yeon; Hong, Kee Suk; Koh, Chang Soon; Lee, Mun Ho

    1977-01-01

    To evaluate the diagnostic significance of the blood disappearance rate of 198 Au-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of 198 Au-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1) In normal control, the mean blood disappearance half time of 198 Au-colloid in supine position was 2.7±0.4 minutes. There was no significant difference of hepatic blood flow in age and sex. 2) In acute hepatitis, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were 3.0±0.45, 3.5±0.74, 7.2±3.6 minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3) In the normal control and acute hepatitis, the decreases of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively.

  4. Three-dimensional optical micro-angiography maps directional blood perfusion deep within microcirculation tissue beds in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ruikang K [Department of Biomedical Engineering, Oregon Health and Science University, Portland, OR 97237 (United States)

    2007-12-07

    Optical micro-angiography (OMAG) is a recently developed method of imaging localized blood perfusion at capillary level resolution within microcirculatory beds. This paper reports that the OMAG is capable of directional blood perfusion mapping in vivo. This is achieved simply by translating the mirror located in the reference arm back and forth while 3D imaging is performed. The mirror which moves toward the incident beam gives the blood perfusion that flows away from the beam direction and vice versa. The approach is experimentally demonstrated by imaging of a flow phantom and then cerebro-vascular perfusion of a live mouse with cranium intact.

  5. Blood transfusion and hepatitis viruses

    African Journals Online (AJOL)

    virus in blood donors: investigation of type-specific differences in serologic reactivity and rate of alanine aminotransferase abnormalities. Transfusion 1993;. 33: 7-13. 45. McFarlane IG, Smith HM, Johnson PJ, Bray GP, Vergani 0, Williams R. Hepatitis. C virus antibodies in chronic active hepatitis: pathogenetic factor or false-.

  6. Blood disappearance rate of /sup 198/Au-colloid and changes of hepatic blood flow during position change in normal persons and in patients with various hepatic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Cho, B Y [Capital Armed Forces General Hospital, Seoul (Republic of Korea); Hong, K S; Koh, C S; Lee, M [Seoul National Univ., Seoul (Republic of Korea). Coll. of Medicine

    1977-01-01

    To evaluate the diagnostic significance of the blood disappearance rate of /sup 198/Au-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of 7,1/sup 98/Au-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1. In normal control, the mean blood disappearance half time of /sup 198/Au-colloid in supine position was 2.7+-0.4 minutes. There was no significant difference of hepatic blood flow in age and sex. 2. In acute hepatitits, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were 3.0+-0.45, 3.5+-0.74, 7.2+-3.6 minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3. In the normal control and acute hepatitis, the decreaces of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively.

  7. The blood disappearance rate of 198Au-colloid and changes of hepatic blood flow during position change in normal persons and in patients with various hepatic diseases

    International Nuclear Information System (INIS)

    Cho, B.Y.; Hong, K.S.; Koh, C.S.; Lee, M.

    1977-01-01

    To evaluate the diagnostic significance of the blood disappearance rate of 198 Au-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of 7,1 98 Au-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1. In normal control, the mean blood disappearance half time of 198 Au-colloid in supine position was 2.7+-0.4 minutes. There was no significant difference of hepatic blood flow in age and sex. 2. In acute hepatitits, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were 3.0+-0.45, 3.5+-0.74, 7.2+-3.6 minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3. In the normal control and acute hepatitis, the decreaces of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively. (author)

  8. Evaluating blood perfusion of the corpus luteum in beef cows during fescue toxicosis.

    Science.gov (United States)

    Cline, G F; Muth-Spurlock, A M; Voelz, B E; Lemley, C O; Larson, J E

    2016-01-01

    The aim of this study was to determine if fescue toxicosis altered blood perfusion in the corpus luteum (CL) and peripheral concentrations of progesterone in cattle. The estrous cycles of 36 nonpregnant Angus or Charolais cows were synchronized in 2 replicates using the CO-Synch+CIDR protocol. Seven days after initiation of the protocol, cows were assigned (d 0) to 1 of 2 dietary treatments: 2.5 kg of 1) Kentucky-31 endophyte-infected (KY31; = 14) or 2) MaxQ novel endophyte (MaxQ; = 12) tall fescue seed. On d 7, ovaries were examined using ultrasonography, and only cows that had 1 CL present remained on the study ( = 26). Images of blood perfusion of CL, blood samples, rectal temperatures, and blood pressure of tails were collected on d 10, 13, 15, and 18. Images of CL blood perfusion were analyzed using ImageJ software for pixel density, and scored visually (0 to 9 with 0 = no perfusion, 9 = complete perfusion) by 2 independent technicians. The MIXED procedure of SAS was used with day as a repeated measure. Least squares means and SEM are reported. Cows receiving KY31 had greater rectal temperatures ( 0.003; 38.76 ± 0.08°C) than those receiving MaxQ (38.44 ± 0.08°C), providing evidence that the cows treated with KY31 were influenced by fescue toxicosis. Pulse pressure and mean arterial pressure were decreased ( cows receiving KY31 (55.26 ± 2.81 and 80.06 ± 2.72 mmHg, respectively) than MaxQ (66.58 ± 3.03 and 91.38 ± 2.93 mmHg, respectively). Concentrations of progesterone were similar ( = 0.54) between cows receiving KY31 (6.04 ± 0.53 ng/mL) or MaxQ (6.36 ± 0.63 ng/mL). Pixel densities ( = 0.14) and visual perfusion scores were similar ( = 0.11) between cows receiving KY31 (1477.20 ± 655.62 pixels and 2.23 ± 0.34, respectively) or MaxQ (2934.70 ± 718.20 pixels and 3.00 ± 0.36, respectively). Mean CL volume was similar ( 0.95) between treatments. In conclusion, blood perfusion of CL or peripheral concentrations of progesterone were not altered at the

  9. Assessment of tumor vascularization with functional computed tomography perfusion imaging in patients with cirrhotic liver disease.

    Science.gov (United States)

    Li, Jin-Ping; Zhao, De-Li; Jiang, Hui-Jie; Huang, Ya-Hua; Li, Da-Qing; Wan, Yong; Liu, Xin-Ding; Wang, Jin-E

    2011-02-01

    Hepatocellular carcinoma (HCC) is a common malignant tumor in China, and early diagnosis is critical for patient outcome. In patients with HCC, it is mostly based on liver cirrhosis, developing from benign regenerative nodules and dysplastic nodules to HCC lesions, and a better understanding of its vascular supply and the hemodynamic changes may lead to early tumor detection. Angiogenesis is essential for the growth of primary and metastatic tumors due to changes in vascular perfusion, blood volume and permeability. These hemodynamic and physiological properties can be measured serially using functional computed tomography perfusion (CTP) imaging and can be used to assess the growth of HCC. This study aimed to clarify the physiological characteristics of tumor angiogenesis in cirrhotic liver disease by this fast imaging method. CTP was performed in 30 volunteers without liver disease (control subjects) and 49 patients with liver disease (experimental subjects: 27 with HCC and 22 with cirrhosis). All subjects were also evaluated by physical examination, laboratory screening and Doppler ultrasonography of the liver. The diagnosis of HCC was made according to the EASL criteria. All patients underwent contrast-enhanced ultrasonography, pre- and post-contrast triple-phase CT and CTP study. A mathematical deconvolution model was applied to provide hepatic blood flow (HBF), hepatic blood volume (HBV), mean transit time (MTT), permeability of capillary vessel surface (PS), hepatic arterial index (HAI), hepatic arterial perfusion (HAP) and hepatic portal perfusion (HPP) data. The Mann-Whitney U test was used to determine differences in perfusion parameters between the background cirrhotic liver parenchyma and HCC and between the cirrhotic liver parenchyma with HCC and that without HCC. In normal liver, the HAP/HVP ratio was about 1/4. HCC had significantly higher HAP and HAI and lower HPP than background liver parenchyma adjacent to the HCC. The value of HBF at the tumor

  10. Xeno- and auto-perfusion of rabbit kidney. Machine perfusion with blood at 37 degrees C

    DEFF Research Database (Denmark)

    Jørgensen, K A; Kemp, E; Barfort, P

    1985-01-01

    damage, exudation, and IgG deposits along the basement membrane of the glomerular capillaries were the discriminative features of the xenoperfusion. In these experiments, we were unable to demonstrate any major role of platelets in the process leading to decreased blood flow.......Five rabbit kidneys were perfused with human blood and another five with their own blood in a re-circulating oxygenated system at 37 degrees C. The flow decreased to 2 ml/min. within 30 min. in all xenoperfusions, while none of the autoperfused had decreased to this level by 60 min. Endothelial...

  11. Method for the assessment of placental blood perfusion using /sup 99/Tc pertechnetate

    Energy Technology Data Exchange (ETDEWEB)

    Suonio, S; Olkkonen, H [Kuopio Central Hospital (Finland)

    1977-10-01

    A radioisotope method was developed for the measurement of placental blood flow using /sup 99/Tc pertechnetate as a tracer and a single detector as a measuring device. The results are given as placental perfusion rate (ml/min/ml) calculated from the tracer-appearance curve. The series consisted of 148 healthy pregnant women between the 28th and 42nd week and fifty pregnancies with a hypertensive disease. In healthy subjects the placental perfusion rate increased by about 32% in the period between 28th and 38th week, but there was a large variation. The perfusion rate showed a tendency to diminish at term. In a group of fifty hypertensive pregnancies a highly significant decrease in the perfusion rate was observed when compared with normal subjects. The conclusion drawn is that this method can be used for the quantitative measurement of placental blood supply.

  12. In vivo tomographic study of cerebral blood perfusion with SPECT in hemiparkinsonian monkeys

    International Nuclear Information System (INIS)

    Chen Shengdi; Xu Delong

    1994-01-01

    The authors present data on the utility of functional brain imaging with 99m Tc-ECD and SPECT in the study of MPTP induced hemiparkinsonism in monkeys. Injection of MPTP into the right common carotid artery of 10 rhesus monkeys produced hemiparkinsonism in the contralateral limbs which responded to antiparkinsonian medication. The unilateral neurotoxicity of the MPTP treated side was confirmed biochemically by marked reduction of DA contents in the nigrostriatum and histologically by selective neuronal loss in the substantia nigra. These monkeys with hemiparkinsonism were studied with SPECT using 99m Tc-ECD as perfusion marker. The results of brain scanning showed that the cerebral blood perfusion of MPTP treated side was significantly depleted 20∼90 days after MPTP intoxication, and returned to normal 8 months after perfusion. The experiment indicates that abnormal cerebral blood perfusion is involved in the course of parkinsonian pathophysiology

  13. Computed Tomography Perfusion of the liver: Assessment of Pure Portal Blood Flow Studied with CT Perfusion During Superior Mesenteric Arterial Portography

    International Nuclear Information System (INIS)

    Kojima, H.; Tanigawa, N.; Komemushi, A.; Kariya, S.; Sawada, S.

    2004-01-01

    Purpose: To quantitatively assess the portal component of hepatic blood flow using computed tomography (CT) perfusion studies during superior mesenteric arterial portography. Material and Methods: Thirty-four patients with hepatocellular carcinoma and liver cirrhosis (LC) and 13 patients with liver metastasis without chronic liver disease were enrolled in this study. Ten milliliters of a non-ionic contrast medium (150 mgI) was injected at a rate of 5 ml/s via a catheter placed in the superior mesenteric artery. Single-slice cine CT images at the level of the main trunk or the right/left main trunk of the portal vein were acquired over 40 s. The deconvolution method was then used on these CT images to measure blood flow (BF), blood volume (BV), and mean transit time (MTT) in (a) liver parenchyma in patients with HCC and liver cirrhosis; (b) liver parenchyma in patients with liver metastasis without cirrhosis; (c) directly in the HCC; and (d) directly in one of the metastases. Results: In 34 LC patients (a), BF, BV, and MTT in the liver parenchyma were 44.7±24.5 ml/min/100 g, 3.9±2.4 ml/100 g, and 10.9±5.5 s, respectively. In 13 patients without cirrhosis (b), BF, BV, and MTT in the liver parenchyma were 89.6±52.0 ml/min/100 g, 6.3 ±3.2 ml/100 g, and 8.7±3.6 sec, respectively. A significant difference in BF and BV was seen in patients with liver cirrhosis compared to those without cirrhosis. BF, BV, and MTT measured directly in HCC (c) were 6.5±4.5 ml/min/100 g, 0.4±0.4 ml/100 g, and 3.0±3.1 sec respectively, and BF, BV, and MTT in liver metastases (d) were 19.3 ± 21.7 ml/min/100 g, 0.6±0.8 ml/100 g, and 1.8±1.6 s, respectively. Conclusion: CT perfusion studies during superior mesenteric arterial portography allow quantitative assessment of pure portal blood flow in the liver

  14. Measurement of regional hepatic blood flow by scintiphotosplenoportography

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, T; Kimura, K; Kamada, T; Abe, H [Osaka Univ. (Japan). Dept. of Radiology and Nuclear Medicine

    1978-08-01

    A new technique for estimating regional hepatic blood flow using the inert gas washout technique and scintillation camera following injection of /sup 133/Xe into the spleen is presented. This technique is easily, rapidly and repeatedly performed and permits the measurement of nutrient hepatic tissue blood flow. Measurement of regional hepatic blood flow in right and/or left lobes was performed in 28 patients. In all but one patient the right lobar flow value was equal to or greater than the left one. The right lobar flow was 86.20 +- 12.83 ml/100 gm/min in 3 patients without liver disease, 75.12 +- 14.54 ml/100 gm/min in 12 with chronic hepatitis and 51.24 +- 17.13 ml/100 gm/min in 11 with liver cirrhosis. This result suggests that hepatic tissue blood flow is significantly decreased in patients with liver cirrhosis. Scintillation camera images of initial xenon distribution in combination with monitor of washout curves over the liver also provide more information on the presence of extra- and intrahepatic shunts. Therefore, this technique appears to be clinically useful in evaluation of hemodynamic phenomena associated with liver diseases.

  15. The Blood Disappearance Rate of 1{sup 98A}u-Colloid and Changes of Hepatic Blood Flow During Position Change in Normal Persons and in Patients with Various Hepatic Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bo Yeon [Capital Armed Force General Hospital, Seoul (Korea, Republic of); Hong, Kee Suk; Koh, Chang Soon; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1977-03-15

    To evaluate the diagnostic significance of the blood disappearance rate of {sup 198}Au-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of {sup 198}Au-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1) In normal control, the mean blood disappearance half time of {sup 198}Au-colloid in supine position was 2.7+-0.4 minutes. There was no significant difference of hepatic blood flow in age and sex. 2) In acute hepatitis, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were 3.0+-0.45, 3.5+-0.74, 7.2+-3.6 minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3) In the normal control and acute hepatitis, the decreases of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively.

  16. Obesity-induced hepatic hypoperfusion primes for hepatic dysfunction after resuscitated hemorrhagic shock.

    Science.gov (United States)

    Matheson, Paul J; Hurt, Ryan T; Franklin, Glen A; McClain, Craig J; Garrison, R Neal

    2009-10-01

    Obese patients (BMI>35) after blunt trauma are at increased risk compared to non-obese for organ dysfunction, prolonged hospital stay, infection, prolonged mechanical ventilation, and mortality. Obesity and non-alcoholic fatty liver disease (NAFLD) produce a low grade systemic inflammatory response syndrome (SIRS) with compromised hepatic blood flow, which increases with body mass index. We hypothesized that obesity further aggravates liver dysfunction by reduced hepatic perfusion following resuscitated hemorrhagic shock (HEM). Age-matched Zucker rats (Obese, 314-519 g & Lean, 211-280 g) were randomly assigned to 4 groups (n = 10-12/group): (1) Lean-Sham; (2) Lean, HEM, and resuscitation (HEM/RES); (3) Obese-Sham; and (4) Obese-HEM/RES. HEM was 40% of mean arterial pressure (MAP) for 60 min; RES was return of shed blood/5 min and 2 volumes of saline/25 min. Hepatic blood flow (HBF) using galactose clearance, liver enzymes and complete metabolic panel were measured over 4 h after completion of RES. Obese rats had increased MAP, heart rate, and fasting blood glucose and BUN concentrations compared to lean controls, required less blood withdrawal (mL/g) to maintain 40% MAP, and RES did not restore BL MAP. Obese rats had decreased HBF at BL and during HEM/RES, which persisted 4 h post RES. ALT and BUN were increased compared to Lean-HEM/RES at 4 h post-RES. These data suggest that obesity significantly contributes to trauma outcomes through compromised vascular control or through fat-induced sinusoidal compression to impair hepatic blood flow after HEM/RES resulting in a greater hepatic injury. The pro-inflammatory state of NAFLD seen in obesity appears to prime the liver for hepatic ischemia after resuscitated hemorrhagic shock, perhaps intensified by insidious and ongoing hepatic hypoperfusion established prior to the traumatic injury or shock.

  17. Analysis of blood flow in a third ventricular ependymoma and an olfactory bulb meningioma by usisng perfusion computed tomography

    International Nuclear Information System (INIS)

    Kishimoto, M.; Yamada, K.; Seok, J.S.; Shimizu, J.; Kobayashi, Y.; Akiba, Y.; Morishita, Y.; Iwasa, A.; Iwasaki, T.; Miyake, Y.

    2008-01-01

    Brain perfusion computed tomography (CT) scanning was performed in a mongrel dog and a golden retriever that were diagnosed with third ventricular tumor and olfactory bulb tumor, respectively, by contrast-enhanced CT. The tumors were pathologically diagnosed as ependymoma and meningioma, respectively. Perfusion CT results revealed that the ependymoma in this study had a lower blood flow, higher blood volume, and greater transit time of blood than the adjacent brain tissue. Further, the meningioma in this study had a higher blood flow, higher blood volume, and greater transit time of blood than the adjacent brain tissue. Perfusion CT can potentially be used for the grading of brain tumors and narrowing differential diagnosis, provided the perfusion CT data of animals are accumulated

  18. Seropositivity for hepatitis B and C in voluntary blood donors

    International Nuclear Information System (INIS)

    Shah, S.M.A.; Ali, A.

    2010-01-01

    After the introduction of blood banks and better storage techniques blood is more widely used in patients for various indications. In Pakistan more than 1.5 million pints of blood are collected each year. Hepatitis B and C virus infections are known to occur in the general population and due to their mode of transmission through blood and blood products, it has made safe blood transfusion difficult and screening of blood absolutely necessary. Objectives of this study were to estimate frequency of Hepatitis B and C in blood donors of local area and recommend measures for safe blood transfusion. Methods: This retrospective cross-sectional study was conduced at the Blood Bank, Department of Pathology, Khyber Teaching Hospital, Peshawar from January 01, 2007 to December 31, 2008. It was carried out on 32,042 voluntary, non-remunerated healthy blood donors. They were screened for Hepatitis B surface antigen (HBsAg) and anti-hepatitis C antibodies (anti-HCV antibodies) by ELISA. The patients' age ranged from 18-52 years. They were all males. Results: Out of 32,042 donors, 632 (1.97%) patients were positive for HBsAg, and 502 (1.57%).were positive for anti-HCV antibodies. Conclusion: Incidence of Hepatitis B and C is varying in different areas. It is recommended that properly screened blood only, using a reliable method like ELISA, be transfused to the patients. (author)

  19. Mucosal blood flow measurements using laser Doppler perfusion monitoring

    Institute of Scientific and Technical Information of China (English)

    Dag Arne Lihaug Hoff; Hans Gregersen; Jan Gunnar Hatlebakk

    2009-01-01

    Perfusion of individual tissues is a basic physiological process that is necessary to sustain oxygenation and nutrition at a cellular level. Ischemia, or the insufficiency of perfusion, is a common mechanism for tissue death or degeneration, and at a lower threshold, a mechanism for the generation of sensory signalling including pain. It is of considerable interest to study perfusion of peripheral abdominal tissues in a variety of circumstances. Microvascular disease of the abdominal organs has been implicated in the pathogenesis of a variety of disorders, including peptic ulcer disease, inflammatory bowel disease and chest pain. The basic principle of laser Doppler perfusion monitoring (LDPM) is to analyze changes in the spectrum of light reflected from tissues as a response to a beam of monochromatic laser light emitted. It reflects the total local microcirculatory blood perfusion, including perfusion in capillaries, arterioles, venules and shunts. During the last 20-25 years, numerous studies have been performed in different parts of the gastrointestinal (GI) tract using LDPM. In recent years we have developed a multi-modal catheter device which includes a laser Doppler probe, with the intent primarily to investigate patients suffering from functional chest pain of presumed oesophageal origin. Preliminary studies show the feasibility of incorporating LDPM into such catheters for performing physiological studies in the GI tract. LDPM has emerged as a research and clinical tool in preference to other methods; but, it is important to be aware of its limitations and account for them when reporting results.

  20. Effects of Constant Flow vs. Constant Pressure Perfusion on Fluid Filtration in Severe Hypothermic Isolated Blood-Perfused Rat Lungs.

    Science.gov (United States)

    Halsøy, Kathrine; Kondratiev, Timofey; Tveita, Torkjel; Bjertnaes, Lars J

    2016-01-01

    Victims of severe accidental hypothermia are prone to fluid extravasation but rarely develop lung edema. We hypothesize that combined hypothermia-induced increase in pulmonary vascular resistance (PVR) and a concomitant fall in cardiac output protect the lungs against edema development. Our aim was to explore in hypothermic-isolated blood-perfused rat lungs whether perfusion at constant pressure influences fluid filtration differently from perfusion at constant flow. Isolated blood-perfused rat lungs were hanging freely in a weight transducer for measuring weight changes (ΔW). Fluid filtration coefficient (Kfc), was determined by transiently elevating left atrial pressure (Pla) by 5.8 mmHg two times each during normothermia (37°C) and during hypothermia (15°C). The lung preparations were randomized to two groups. One group was perfused with constant flow (Constant flow group) and the other group with constant pulmonary artery pressure (Constant PPA group). Microvascular pressure (Pmv) was determined before and during elevation of Pla (ΔPmv) by means of the double occlusion technique. Kfc was calculated with the formula Kfc = ΔW/ΔPmv/min. All Kfc values were normalized to predicted lung weight (P LW ), which was based on body weight (BW) according to the formula: P LW  = 0.0053 BW - 0.48 and presented as Kfc PLW in mg/min/mmHg/g. At cessation, bronchoalveolar lavage (BAL) fluid/perfusate protein concentration (B/P) ratio was determined photometrically. Data were analyzed with parametric or non-parametric tests as appropriate. p  Kfc PLW and B/P ratio increased significantly by more than 10-fold during hypothermia concerted by visible signs of edema in the trachea. Hemoglobin and hematocrit increased within the Constant flow group and between the groups at cessation of the experiments. In hypothermic rat lungs perfused at constant flow, fluid filtration coefficient per gram P LW and B/P ratio increased more than 10-fold concerted by increased

  1. Classification of hypervascular liver lesions based on hepatic artery and portal vein blood supply coefficients calculated from triphasic CT scans.

    Science.gov (United States)

    Boas, F Edward; Kamaya, Aya; Do, Bao; Desser, Terry S; Beaulieu, Christopher F; Vasanawala, Shreyas S; Hwang, Gloria L; Sze, Daniel Y

    2015-04-01

    Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver lesions. Triphasic CTs of 46 malignant and 32 benign liver lesions were analyzed. For each phase, regions of interest were drawn in the arterially enhancing portion of each lesion, as well as the background liver, aorta, and portal vein. Hepatic artery and portal vein blood supply coefficients for each lesion were then calculated by expressing the enhancement curve of the lesion as a linear combination of the enhancement curves of the aorta and portal vein. Hepatocellular carcinoma (HCC) and hypervascular metastases, on average, both had increased hepatic artery coefficients compared to the background liver. Compared to HCC, benign lesions, on average, had either a greater hepatic artery coefficient (hemangioma) or a greater portal vein coefficient (focal nodular hyperplasia or transient hepatic attenuation difference). Hypervascularity with washout is a key diagnostic criterion for HCC, but it had a sensitivity of 72 % and specificity of 81 % for diagnosing malignancy in our diverse set of liver lesions. The sensitivity for malignancy was increased to 89 % by including enhancing lesions that were hypodense on all phases. The specificity for malignancy was increased to 97 % (p = 0.039) by also examining hepatic artery and portal vein blood supply coefficients, while maintaining a sensitivity of 76 %.

  2. A Review of Liver Perfusion Method in Toxicology Studies

    Directory of Open Access Journals (Sweden)

    M karami

    2014-06-01

    Full Text Available Introduction: The isolated perfused rat liver is an accepted method in toxicology studies. The isolated perfused rat liver (IPRL is a useful experimental system for evaluating hepatic function without the influence of other organ systems, undefined plasma constituents, and neural-hormonal effects. Methods: The untreated male rats (180-220gr body weight were anesthetised with ether and then surgery with proper method. The abdomen was opened through a midline and one transversal incision and the bile duct was cannulated. Heparin sodium solution (0.5 ml; 500 U/ml in 0.9% NaCl was injected via the abdominal vena cava to prevent blood clotting. The liver inferior venacava was cannulated with PE-10 tubing and secured. The portal vein was immediately cannulated with an 23gr catheter which was secured and then liver was perfused in situ by Krebs- Henseleit buffer (pH 7.4; saturated with 95% O2 and 5% CO2; 37°C at a flow rate of 20 ml/min for 3hr. Temperature, perfusion pressure, flow rate and perfusion fluid pH were closely monitored during the perfusion. Results: Transferase enzymes (ALT, AST alterations can be widely used as a measure of biochemical alterations in order to assess liver damage due to use of drugs such as isoniazid (INH and animal and plant toxins. Accumulated material in gallbladder are valuable samples to assess the level of Glutathione (GSH. Sections of perfused liver tissue can also be effectively analyzed for pathological aspects such as necrosis, fibrosis, cellularity. Conclusion: The isolated perfused rat liver (IPRL is a useful and Sutible experimental system for evaluating hepatic function. In this system, the effects of adjacent organs, on the liver is minimized

  3. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  4. Scaling of cerebral blood perfusion in primates and marsupials.

    Science.gov (United States)

    Seymour, Roger S; Angove, Sophie E; Snelling, Edward P; Cassey, Phillip

    2015-08-01

    The evolution of primates involved increasing body size, brain size and presumably cognitive ability. Cognition is related to neural activity, metabolic rate and rate of blood flow to the cerebral cortex. These parameters are difficult to quantify in living animals. This study shows that it is possible to determine the rate of cortical brain perfusion from the size of the internal carotid artery foramina in skulls of certain mammals, including haplorrhine primates and diprotodont marsupials. We quantify combined blood flow rate in both internal carotid arteries as a proxy of brain metabolism in 34 species of haplorrhine primates (0.116-145 kg body mass) and compare it to the same analysis for 19 species of diprotodont marsupials (0.014-46 kg). Brain volume is related to body mass by essentially the same exponent of 0.70 in both groups. Flow rate increases with haplorrhine brain volume to the 0.95 power, which is significantly higher than the exponent (0.75) expected for most organs according to 'Kleiber's Law'. By comparison, the exponent is 0.73 in marsupials. Thus, the brain perfusion rate increases with body size and brain size much faster in primates than in marsupials. The trajectory of cerebral perfusion in primates is set by the phylogenetically older groups (New and Old World monkeys, lesser apes) and the phylogenetically younger groups (great apes, including humans) fall near the line, with the highest perfusion. This may be associated with disproportionate increases in cortical surface area and mental capacity in the highly social, larger primates. © 2015. Published by The Company of Biologists Ltd.

  5. A comparison of dobutamine and levosimendan on hepatic blood flow in patients with a low cardiac output state after cardiac surgery: a randomised controlled study.

    Science.gov (United States)

    Alvarez, J; Baluja, A; Selas, S; Otero, P; Rial, M; Veiras, S; Caruezo, V; Taboada, M; Rodriguez, I; Castroagudin, J; Tome, S; Rodriguez, A; Rodriguez, J

    2013-11-01

    Liver dysfunction due to a low cardiac output state after cardiac surgery is associated with a poor prognosis, but whether one inotrope is superior to another in improving hepatic perfusion remains uncertain. This study compared the systemic and hepatic haemodynamic effects of levosimendan to dobutamine in patients with a low cardiac output state (cardiac index flow (ml/min): 614.0±124.7, 585.9±144.8; pulsatility index: 2.02±0,28, 2.98±0.27 versus the levosimendan group: cardiac index: 3.02± 0.27, 2.98± 0.30; portal vein flow: 723.0± 143.5, 702.9±117.8; pulsatility index: 1.71±0.26, 1.73±0.27). The improvement in portal vein blood flow at 48 hours was significantly better after levosimendan than dobutamine (41% vs. 11% increment from baseline, Pflow through both the hepatic artery and portal venous system, whereas dobutamine can only improve the portal venous blood flow without vasodilating the hepatic artery.

  6. Hepatitis C virus antibodies among blood donors in Jos, Nigeria ...

    African Journals Online (AJOL)

    Background: Hepatitis C virus (HCV) is one of the hepatitis agents known to be transmitted through blood and blood products. Hepatitis C virus has been implicated as a major cause of chronic liver disease and hepatocellular carcinoma worldwide. This study was, therefore, undertaken with the objective of determining the ...

  7. Relationship between dynamic infrared thermal images and blood perfusion rate of the tongue in anaemia patients

    Science.gov (United States)

    Xie, Haiwei; Zhang, Yan

    2018-03-01

    The relationship between dynamic infrared (IR) thermal images and blood perfusion rate of the tongues of anaemia patients was investigated. Blood perfusion rates at multiple locations on the tongues of 62 anaemia patients and 70 control subjects were measured. For both groups of subjects, dynamic IR thermal images were also recorded within 16 s after the mouth opened. The results showed that the blood perfusion rates at different sites (apex, middle, left side and right side) on the tongues in anaemia patients (3.49, 3.71, 3.85 and 3.77 kg/s m-3) were significantly lower than those at the corresponding sites in control subjects (4.45, 4.66, 4.81 and 4.70 kg/s m-3). After the mouth opened, the tongue temperature decreased more rapidly in anaemia patients than in control subjects. To analyse the heat transfer mechanism, a transient heat transfer model of the tongue was developed. The tongue temperatures in anaemia patients and control subjects were calculated using this model and compared to the tongue temperatures measured by the IR thermal imager. The relationship between the tongue surface temperature and the tongue blood perfusion rate was analysed. The simulation results indicated that the low blood perfusion rate and the correlated changes in anaemia patients can cause faster temperature decreases of the tongue surface.

  8. Influence of repetitive finger puncturing on skin perfusion and capillary blood analysis in patients with diabetes mellitus

    NARCIS (Netherlands)

    de Graaff, J. C.; Hemmes, G. J.; Bruin, T.; Ubbink, D. T.; Michels, R. P.; Jacobs, M. J.; Sanders, G. T.

    1999-01-01

    Frequent puncturing of fingers to check blood glucose in patients with type 1 diabetes might alter skin perfusion and, hence, influence the representativeness of the blood sample. We investigated the influence of repetitive puncturing on skin microcirculatory perfusion using laser Doppler fluxmetry

  9. Evaluation of a breath-motion-correction technique in reducing measurement error in hepatic CT perfusion imaging

    International Nuclear Information System (INIS)

    He Wei; Liu Jianyu; Li Xuan; Li Jianying; Liao Jingmin

    2009-01-01

    Objective: To evaluate the effect of a breath-motion-correction (BMC) technique in reducing measurement error of the time-density curve (TDC) in hepatic CT perfusion imaging. Methods: Twenty-five patients with suspected liver diseases underwent hepatic CT perfusion scans. The right branch of portal vein was selected as the anatomy of interest and performed BMC to realign image slices for the TDC according to the rule of minimizing the temporal changes of overall structures. Ten ROIs was selected on the right branch of portal vein to generate 10 TDCs each with and without BMC. The values of peak enhancement and the time-to-peak enhancement for each TDC were measured. The coefficients of variation (CV) of peak enhancement and the time-to-peak enhancement were calculated for each patient with and without BMC. Wilcoxon signed ranks test was used to evaluate the difference between the CV of the two parameters obtained with and without BMC. Independent-samples t test was used to evaluate the difference between the values of peak enhancement obtained with and without BMC. Results: The median (quartiles) of CV of peak enhancement with BMC [2.84% (2.10%, 4.57%)] was significantly lower than that without BMC [5.19% (3.90%, 7.27%)] (Z=-3.108,P<0.01). The median (quartiles) of CV of time-to-peak enhancement with BMC [2.64% (0.76%, 4.41%)] was significantly lower than that without BMC [5.23% (3.81%, 7.43%)] (Z=-3.924, P<0.01). In 8 cases, TDC demonstrated statistically significant higher peak enhancement with BMC (P<0.05). Conclusion: By applying the BMC technique we can effectively reduce measurement error for parameters of the TDC in hepatic CT perfusion imaging. (authors)

  10. Increased brainstem perfusion, but no blood-brain barrier disruption, during attacks of migraine with aura

    DEFF Research Database (Denmark)

    Hougaard, Anders; Amin, Faisal M; Christensen, Casper E

    2017-01-01

    symptoms are related to the headache phase of migraine. Animal studies suggest that cortical spreading depression, the likely mechanism of migraine aura, causes disruption of the blood-brain barrier and noxious stimulation of trigeminal afferents leading to activation of brainstem nuclei and triggering...... of migraine headache. We used the sensitive and validated technique of dynamic contrast-enhanced high-field magnetic resonance imaging to simultaneously investigate blood-brain barrier permeability and tissue perfusion in the brainstem (at the level of the lower pons), visual cortex, and brain areas......-free day. The mean time from attack onset to scanning was 7.6 h. We found increased brainstem perfusion bilaterally during migraine with aura attacks. Perfusion also increased in the visual cortex and posterior white matter following migraine aura. We found no increase in blood-brain barrier permeability...

  11. Intracellular mechanism of action of sympathetic hepatic nerves on glucose and lactate balance in perfused rat liver

    NARCIS (Netherlands)

    Ballé, C.; Beuers, U.; ENGELHARDT, R.; JUNGERMANN, K.

    1987-01-01

    In rat liver perfused in situ stimulation of the nerve plexus around the hepatic artery and the portal vein caused an increase in glucose output and a shift from lactate uptake to output. The effects of nerve stimulation on some key enzymes, metabolites and effectors of carbohydrate metabolism were

  12. CT perfusion for determination of pharmacologically mediated blood flow changes in an animal tumor model.

    Science.gov (United States)

    Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum

    2007-06-01

    To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible

  13. The interactive effects of a gradual temperature decrease and long-term food deprivation on cardiac and hepatic blood flows in rainbow trout (Oncorhynchus mykiss).

    Science.gov (United States)

    Petersen, L H; Dzialowski, E; Huggett, D B

    2011-11-01

    The aim of the present study was to determine the extent to which the fish liver is perfused with blood. Transonic® flow probes were therefore implanted around the ventral aorta and hepatic vein(s) to record baseline blood flows in rainbow trout (Oncorhynchus mykiss) previously held under two different feeding regimes (food-deprived or fed to satiation, 8-12 weeks). Fish from both groups were exposed to a gradual temperature decrease (12°C to 5°C) and physical disturbance. Cardiac output (Q), stroke volume (Sv) and hepatic venous blood flow (HVBF) were significantly reduced in food-deprived trout at 12°C. Heart rate was not significantly affected by nutritional status, but was significantly reduced when temperature was decreased to 5°C. Physically disturbing each fish at 12°C and 5°C showed that the performance capacity of the heart was not affected by food deprivation as the capacity to increase Q and Sv was not reduced in the food-deprived group. Overall this study showed that food deprivation in rainbow trout reduced cardiac and hepatic blood flows. However, long-term food deprivation did not affect the capacity of the heart to acutely increase performance. Copyright © 2011. Published by Elsevier Inc.

  14. Impaired healing of cervical oesophagogastrostomies can be predicted by estimation of gastric serosal blood perfusion by laser Doppler flowmetry.

    Science.gov (United States)

    Pierie, J P; De Graaf, P W; Poen, H; Van der Tweel, I; Obertop, H

    1994-11-01

    To assess the value of relative blood perfusion of the gastric tube in prediction of impaired healing of cervical oesophagogastrostomies. Prospective study. University hospital, The Netherlands. Thirty patients undergoing transhiatal oesophagectomy and partial gastrectomy for cancer of the oesophagus or oesophagogastric junction, with gastric tube reconstruction and cervical oesophagogastrostomy. Operative measurement of gastric blood perfusion at four sites by laser Doppler flowmetry and perfusion of the same sites after construction of the gastric tube expressed as a percentage of preconstruction values. The relative perfusion at the most proximal site of the gastric tube was significantly lower than at the more distal sites (p = 0.001). Nine of 18 patients (50%) in whom the perfusion of the proximal gastric tube was less than 70% of preconstruction values developed an anastomotic stricture, compared with only 1 of 12 patients (8%) with a relative perfusion of 70% or more (p = 0.024). A reduction in perfusion of the gastric tube did not predict leakage. Impaired anastomotic healing is unlikely if relative perfusion is 70% or more of preconstruction values. Perfusion of less than 70% partly predicts the occurrence of anastomotic stricture, but leakage cannot be predicted. Factors other than blood perfusion may have a role in the process of anastomotic healing.

  15. Regional cerebral blood flow assessed by single photon emission computed tomography (SPECT) in dogs with congenital portosystemic shunt and hepatic encephalopathy.

    Science.gov (United States)

    Or, Matan; Peremans, Kathelijne; Martlé, Valentine; Vandermeulen, Eva; Bosmans, Tim; Devriendt, Nausikaa; de Rooster, Hilde

    2017-02-01

    Regional cerebral blood flow (rCBF) in eight dogs with congenital portosystemic shunt (PSS) and hepatic encephalopathy (HE) was compared with rCBF in eight healthy control dogs using single photon emission computed tomography (SPECT) with a 99m technetium-hexamethylpropylene amine oxime ( 99m Tc-HMPAO) tracer. SPECT scans were abnormal in all PSS dogs. Compared to the control group, rCBF in PSS dogs was significantly decreased in the temporal lobes and increased in the subcortical (thalamic and striatal) area. Brain perfusion imaging alterations observed in the dogs with PSS and HE are similar to those in human patients with HE. These findings suggest that dogs with HE and PSS have altered perfusion of mainly the subcortical and the temporal regions of the brain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Determination of hepatic fractional clearance of radioactive gold colloids for a measure of effective hepatic blood flow

    International Nuclear Information System (INIS)

    Fujii, Masahiro

    1979-01-01

    For a measure of effective blood flow, a hepatic fractional clearance of 198 Au-colloids was determined, which was obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic uptake was determined with a gamma camera. The counts over the liver was corrected for body weight and height. The method was considered sufficiently simple for routine use. 198 Au-colloids were obtained from Dainabot Lab. and CIS. The former gave 64% higher values of disappearance rate than the latter, without any change in the organ distribution. A quality control tests were applied over a six-year period to the disappearance rates. Reproducibility within 95 to confidence limits was found for both groups. In 28 normal control subjects, hepatic fractional clearance of the colloids from Dainabot Lab. was 18.5 +- 3.4%/min. In patients with progressed hepatic disease, both hepatic fractional clearance and final hepatic uptake were decreased, showing that the determination of hepatic uptake is necessary in measuring effective hepatic blood flow by the colloidal clearance method. The influence of splenic uptake is discussed in relation to hepatic blood flow measurement. (author)

  17. [Hepatitis E virus: Blood transfusion implications].

    Science.gov (United States)

    Gallian, P; Piquet, Y; Assal, A; Djoudi, R; Chiaroni, J; Izopet, J; Tiberghien, P

    2014-11-01

    Hepatitis E virus (HEV) is a non-enveloped RNA virus transmitted by the fecal-oral route. Autochthonous hepatitis E occurring in developed countries is caused by genotypes 3 and 4 and is a zoonotic infection. Humans are infected mostly after ingestion of undercooked meat from infected animals. Most HEV 3 and 4 infections are clinically inapparent. However, genotype 3 (HEV 3) can lead to chronic hepatitis in immuno-compromised patients such as organ-transplant recipients and patients with haematological malignancies. In Europe, HEV 3 is implicated in transfusion-transmitted HEV infection. In France, as observed in several European countries, prevalence of HEV RNA and specific IgG antibodies are high indicating that viral circulation is important. The systematic HEV NAT screening of blood donations used for preparation of solvent detergent plasma indicate that 1 to 2218 donation is infected by HEV RNA. The need or implementation's impacts of safety measures to prevent HEV transmission by blood transfusion are under reflexion by French's health authorities. The HEV NAT screening is the only available tool of prevention. Alternative strategies are under investigation including individual or mini pool NAT testing all or part of blood donations. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Gamma graphic findings in giant hepatic hemangioma

    International Nuclear Information System (INIS)

    Cano, R.; Morales, R.; Mendoza, P.; Ramirez, E.; Aguilar, C.

    1994-01-01

    The aim of the present work is to describe gamma graphic findings in patients with giant hepatic hemangiomas, when evaluated with 99m Tc red blood cell (RBC) imaging. Three patients with clinical suspicion of giant hepatic hemangiomas, who had had, ultrasound and computed tomography were studied with RBC using in vivo labelling with pyrophosphate. All cases had dynamic and static views. All cases showed hypoperfusion in dynamics views and over perfusion in delayed studies. Surgery confirmed diagnosis in two cases. 99m Tc RBC is a good method for diagnosis of giant hepatic hemangioma, which generally needs surgical treatment. (Authors). 24 refs., 2 figs

  19. Association of ABO and Rh blood group types to hepatitis B, hepatitis C, HIV and syphillis infection, a five year experience in healthy blood donors in a tertiary care hospital

    International Nuclear Information System (INIS)

    Batool, Z.; Durrani, S.H.; Tariq, S.

    2017-01-01

    Aim of the study: The aim of the study was to find out the frequency of Hepatitis B Hepatitis C, Syphilis, HIV and malaria in apparently healthy blood donors and to find out any association between ABO and Rh blood groups. Methods: It was a descriptive study carried out at Rehman Medical Institute laboratory. All blood donors who volunteered for blood donation from Jan 2008 to Dec 2014 were reviewed for blood groups and screening tests. Those who were eligible were then screened for Hepatitis B, Hepatitis C, HIV, syphilis and malaria on Architect 8200i through chemiluminescent immunoassay whereas malaria was screened by a thin film. Blood group was determined by both forward and reverse grouping. Statistical analysis was carried out using SPSS software and expressed as frequencies. Results: A total of 41033 apparently healthy donors were included in the study. All of them were voluntary donors. Their age ranged from 18-70 years with a mean age of 38+-10.5 years. Out of these 41033, 40245 (98.3%) were males and 788(1.9%) were females. The most frequent blood group was B positive followed by O positive. Out of 41033 donors 961 (2.30%) had Hepatitis B, 566 (1.30%) had Hepatitis C, 363 (0.90%) had syphilis, 311 (0.76%) had malaria and 30 (0.07%) had HIV. There is a significant association between A blood group and HIV and hepatitis B. Donors with blood group O had no significant association with any blood transmitted infection. Conclusion: Blood group O may have some influence in protecting against blood transmitted infection. People having Blood group A are more prone to get Hepatitis B and HIV. (author)

  20. Evaluation of ocular acupuncture on cerebral infarction with cerebral blood flow perfusion imaging

    International Nuclear Information System (INIS)

    Li Yuge; Gao Qinyi; Wang Shuang; Zhao Yong

    2008-01-01

    To evaluate the immediate effect of ocular acupuncture on patients, an method of SPECT image of cerebral blood flow daily stress test was established. 10 patients diagnosed as cerebral infarction by CT or MRI were tested. They all received 99 Tc m -ECD SPECT imaging at twice before and after ocular acupuncture. By means of image subtraction technique and semi-quantitative method of regional interesting area, the change of regional cerebral blood flow was observed between the two images. Under restful state perfusion of cerebral blood flow in 18 foci was low at the frontal lobe, the cerebellum, the basal ganglia and temporal lobe. After ocular acupuncture, the perfusions were obviously increased in 16 foci among them and the reactivity of the frontal lobe and the cerebellum to ocular acupuncture was higher, the average improvement rate of which was 55.15% and 53.06% respectively, lower in the basal ganglia and temporal lobe, the average improvement rate was 31.79% and 36.67% respectively. 99 Tc m -ECD SPECT cerebral perfusion image has some significant clinic value for evaluating the effect of ocular acupuncture to treating cerebral infarction. (authors)

  1. Blood Perfusion in Human Eyelid Skin Flaps Examined by Laser Speckle Contrast Imaging-Importance of Flap Length and the Use of Diathermy.

    Science.gov (United States)

    Nguyen, Cu Dinh; Hult, Jenny; Sheikh, Rafi; Tenland, Kajsa; Dahlstrand, Ulf; Lindstedt, Sandra; Malmsjö, Malin

    2017-10-11

    It is well known that blood perfusion is important for the survival of skin flaps. As no study has been conducted to investigate how the blood perfusion in human eyelid skin flaps is affected by the flap length and diathermy, the present study was carried out to investigate these in patients. Fifteen upper eyelids were dissected as part of a blepharoplastic procedure, releasing a 30-mm long piece of skin, while allowing the 5 mm wide distal part of the skin to remain attached, to mimic a skin flap (hereafter called a "skin flap"). Blood perfusion was measured before and after repeated diathermy, using laser speckle contrast imaging. Blood perfusion decreased from the base to the tip of the flap: 5 mm from the base, the perfusion was 69%, at 10 mm it was 40%, at 15 mm it was 20%, and at 20 mm it was only 13% of baseline values. Diathermy further decreased blood perfusion (measured 15 mm from the base) to 13% after applying diathermy for the first time, to 6% after the second and to 4% after the third applications of diathermy. Blood perfusion falls rapidly with distance from the base of skin flaps on the human eyelid, and diathermy reduces blood perfusion even further. Clinically, it may be advised that flaps with a width of 5 mm be no longer than 15 mm (i.e., a width:length ratio of 1:3), and that the use of diathermy should be carefully considered.

  2. Renal perfusion scintiscan

    Science.gov (United States)

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  3. Renal perfusion in chronic liver diseases: Evaluation by radiotechnetium renography

    International Nuclear Information System (INIS)

    Fanfani, G.; Fratello, A.; Mele, M.; Conte, E.; D'Addabbo, A.; Greco, L.

    1985-01-01

    Twenty-four patients with chronic liver diseases and seven normal controls were studied using renal and hepatic radiotechnetium angiography. The time-activity histograms generated were employed to calculate both the renal perfusion index (RPI) and the hepatic perfusion index (HPI). Renal perfusion proved to be reduced not only in cirrhotic patients but also in patients with aggressive chronic hepatitis, as well as in those with persistent chronic hepatitis. The HPI, which is to be considered as being strictly dependent on portal flow, only fell significantly in the group of cirrhotic patients. In all patient groups, the correlation coefficient between the HPI and RPI (mean of the two kidneys) was low (r=0.275) and not significant (P>0.05). After Warren's splenorenal derivation, renal perfusion did not improve but worsened, particularly in the left kidney where derivation anastomosis probably caused a venous overload. (orig.)

  4. Technical Considerations in Percutaneous Hepatic Perfusion—A Multi-Center Experience

    Science.gov (United States)

    Antoine, Radcliffe A.

    2011-01-01

    Abstract: Patients diagnosed with primary or metastatic liver cancer face a daunting future that is complicated by limited treatment options. Percutaneous hepatic perfusion is a novel approach to chemotherapy delivery that offers significant benefits over contemporary modalities. Percutaneous hepatic perfusion is a procedure in which a chemotherapeutic agent is administered at high doses via the hepatic artery where it perfuses the liver, is extracted and filtered using a veno-veno bypass circuit, a fenestrated multi-lumen double-balloon catheter, and two biocompatible hemoperfusion filters. Venous access is gained at the groin through the femoral vein after which the catheter is advanced and positioned in the inferior vena cava just below the right atrium. The catheter’s proximal and distal balloons are inflated to occlude the inferior vena cava above and below the hepatic veins. The occlusion isolated the chemo-rich venous outflow of the liver from the systemic venous circulation. This maneuver also diverts venous blood returning to the heart from lower extremities of the azygos vein. Once the patient is on bypass, the agent is infused through the hepatic artery where it saturates the liver. The chemorich venous outflow is extracted through the double-balloon catheter by the bypass circuit. The blood is continuously filtered and cleared of the agent as it passes through the filters and returned to the patient through a catheter placed in the right internal jugular vein. A phase I study demonstrated efficacy with an overall radiographic response rate of 30% observed in treated patients. In 10 patients with ocular melanoma, a 50% overall response rate was observed, including two complete responses. The technique is minimally invasive and can be performed safely by a well-trained multi-disciplinary team. It offers significant benefits including multiple procedures without risks commonly associated with open abdominal surgery. PMID:21449232

  5. Laser speckle contrast imaging of skin blood perfusion responses induced by laser coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Ogami, M; Kulkarni, R; Wang, H; Reif, R; Wang, R K [University of Washington, Department of Bioengineering, Seattle, Washington 98195 (United States)

    2014-08-31

    We report application of laser speckle contrast imaging (LSCI), i.e., a fast imaging technique utilising backscattered light to distinguish such moving objects as red blood cells from such stationary objects as surrounding tissue, to localise skin injury. This imaging technique provides detailed information about the acute perfusion response after a blood vessel is occluded. In this study, a mouse ear model is used and pulsed laser coagulation serves as the method of occlusion. We have found that the downstream blood vessels lacked blood flow due to occlusion at the target site immediately after injury. Relative flow changes in nearby collaterals and anastomotic vessels have been approximated based on differences in intensity in the nearby collaterals and anastomoses. We have also estimated the density of the affected downstream vessels. Laser speckle contrast imaging is shown to be used for highresolution and fast-speed imaging for the skin microvasculature. It also allows direct visualisation of the blood perfusion response to injury, which may provide novel insights to the field of cutaneous wound healing. (laser biophotonics)

  6. Laser speckle contrast imaging of skin blood perfusion responses induced by laser coagulation

    Science.gov (United States)

    Ogami, M.; Kulkarni, R.; Wang, H.; Reif, R.; Wang, R. K.

    2014-08-01

    We report application of laser speckle contrast imaging (LSCI), i.e., a fast imaging technique utilising backscattered light to distinguish such moving objects as red blood cells from such stationary objects as surrounding tissue, to localise skin injury. This imaging technique provides detailed information about the acute perfusion response after a blood vessel is occluded. In this study, a mouse ear model is used and pulsed laser coagulation serves as the method of occlusion. We have found that the downstream blood vessels lacked blood flow due to occlusion at the target site immediately after injury. Relative flow changes in nearby collaterals and anastomotic vessels have been approximated based on differences in intensity in the nearby collaterals and anastomoses. We have also estimated the density of the affected downstream vessels. Laser speckle contrast imaging is shown to be used for highresolution and fast-speed imaging for the skin microvasculature. It also allows direct visualisation of the blood perfusion response to injury, which may provide novel insights to the field of cutaneous wound healing.

  7. 42 CFR 410.63 - Hepatitis B vaccine and blood clotting factors: Conditions.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Hepatitis B vaccine and blood clotting factors... Other Health Services § 410.63 Hepatitis B vaccine and blood clotting factors: Conditions... under § 410.10, subject to the specified conditions: (a) Hepatitis B vaccine: Conditions. Effective...

  8. Insulin resistance is associated with lower arterial blood flow and reduced cortical perfusion in cognitively asymptomatic middle-aged adults

    Science.gov (United States)

    Hoscheidt, Siobhan M; Kellawan, J Mikhail; Berman, Sara E; Rivera-Rivera, Leonardo A; Krause, Rachel A; Oh, Jennifer M; Beeri, Michal S; Rowley, Howard A; Wieben, Oliver; Carlsson, Cynthia M; Asthana, Sanjay; Johnson, Sterling C; Schrage, William G

    2016-01-01

    Insulin resistance (IR) is associated with poor cerebrovascular health and increased risk for dementia. Little is known about the unique effect of IR on both micro- and macrovascular flow particularly in midlife when interventions against dementia may be most effective. We examined the effect of IR as indexed by the Homeostatic Model Assessment of Insulin Resistance (HOMA-IR) on cerebral blood flow in macro- and microvessels utilizing magnetic resonance imaging (MRI) among cognitively asymptomatic middle-aged individuals. We hypothesized that higher HOMA-IR would be associated with reduced flow in macrovessels and lower cortical perfusion. One hundred and twenty cognitively asymptomatic middle-aged adults (57 ± 5 yrs) underwent fasting blood draw, phase contrast-vastly undersampled isotropic projection reconstruction (PC VIPR) MRI, and arterial spin labeling (ASL) perfusion. Higher HOMA-IR was associated with lower arterial blood flow, particularly within the internal carotid arteries (ICAs), and lower cerebral perfusion in several brain regions including frontal and temporal lobe regions. Higher blood flow in bilateral ICAs predicted greater cortical perfusion in individuals with lower HOMA-IR, a relationship not observed among those with higher HOMA-IR. Findings provide novel evidence for an uncoupling of macrovascular blood flow and microvascular perfusion among individuals with higher IR in midlife. PMID:27488909

  9. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  10. Radio Immuno Assay (RIA) for detection of hepatitis B virus in blood donors

    Energy Technology Data Exchange (ETDEWEB)

    Pereva, K I [Central Blood Bank, Colombo, General Hospital, Colombo (Sri Lanka)

    1990-03-01

    Hepatitis B is a blood-borne viral disease which affects more than 250 million people world-wide, mostly in the third world. The disease can cause fatal liver cancer in adult life, if infected when young. This deals with the laboratory techniques used in the detection of hepatitis B virus of the donor blood. Natural blood transfusion service of Sri Lanka screens the hepatitis B surface antigen using the RIA technique to find out whether the normal healthy donors without a history of hepatitis are infected with hepatitis B virus.

  11. Wet cupping therapy improves local blood perfusion and analgesic effects in patients with nerve-root type cervical spondylosis.

    Science.gov (United States)

    Meng, Xiang-Wen; Wang, Ying; Piao, Sheng-Ai; Lv, Wen-Tao; Zhu, Cheng-Hui; Mu, Ming-Yuan; Li, Dan-Dan; Liu, Hua-Peng; Guo, Yi

    2018-01-15

    To observe wet cupping therapy (WCT) on local blood perfusion and analgesic effects in patients with nerve-root type cervical spondylosis (NT-CS). Fifty-seven NT-CS patients were randomly divided into WCT group and Jiaji acupoint-acupuncture (JA) group according a random number table. WCT group (30 cases) was treated with WCT for 10 min, and JA group (27 cases) was treated with acupuncture for 10 min. The treatment effificacies were evaluated with a Visual Analogue Scale (VAS). Blood perfusion at Dazhui (GV 14) and Jianjing (GB 21) acupoints (affected side) was observed with a laser speckle flflowmetry, and its variations before and after treatment in both groups were compared as well. In both groups, the VAS scores signifificantly decreased after the intervention (P<0.01), while the blood perfusion at the two acupoints signifificantly increased after intervention (P<0.05); however, the increasement magnitude caused by WCT was obvious compared with JA (P<0.05). WCT could improve analgesic effects in patients with NT-CS, which might be related to increasing local blood perfusion of acupunct points.

  12. Finite-element simulation of blood perfusion in muscle tissue during compression and sustained contraction

    NARCIS (Netherlands)

    Vankan, W.J.; Huyghe, J.M.R.J.; Slaaf, D.W.; Donkelaar, van C.C.; Drost, M.R.; Janssen, J.D.; Huson, A.

    1997-01-01

    Mechanical interaction between tissue stress and blood perfusion in skeletal muscles plays an important role in blood flow impediment during sustained contraction. The exact mechanism of this interaction is not clear, and experimental investigation of this mechanism is difficult. We developed a

  13. Prevalence of Hepatitis-B Surface Antigen among Blood Donors in ...

    African Journals Online (AJOL)

    Information is scarce on the prevalence of Hepatitis-B Virus (HBV) infection among blood donors in Taraba State. Hepatitis-B surface antigen (HBsAg) ELISA [Gudans Industrial Hong 2 Kou, China] was used to determine the prevalence of HBsAg among 804 blood donors aged between 11 and 65 years in Federal Medical ...

  14. Assessment of liver circulation by quantitative scintiangiography: Evaluation of the relative contribution of the hepatic arterial and portal venous blood flows to liver perfusion

    International Nuclear Information System (INIS)

    Molino, G.; Squadrone, E.; Baccegal, M.; Magnani, C.

    1989-01-01

    Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq 99m Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio was found to be increased in liver cirrhosis and in shunted patients and therefore, in spite of the limitations underlined before and of the absence of data on the reproducibility of consecutive injections, hepatic scintiangiography may be of some clinical utility. (orig.)

  15. Cryotherapy-Induced Persistent Vasoconstriction After Cutaneous Cooling: Hysteresis Between Skin Temperature and Blood Perfusion

    Science.gov (United States)

    Khoshnevis, Sepideh; Craik, Natalie K.; Matthew Brothers, R.; Diller, Kenneth R.

    2016-01-01

    The goal of this study was to investigate the persistence of cold-induced vasoconstriction following cessation of active skin-surface cooling. This study demonstrates a hysteresis effect that develops between skin temperature and blood perfusion during the cooling and subsequent rewarming period. An Arctic Ice cryotherapy unit (CTU) was applied to the knee region of six healthy subjects for 60 min of active cooling followed by 120 min of passive rewarming. Multiple laser Doppler flowmetry perfusion probes were used to measure skin blood flow (expressed as cutaneous vascular conductance (CVC)). Skin surface cooling produced a significant reduction in CVC (P cryotherapy. PMID:26632263

  16. Seroprevalence of hepatitis C virus antibodies amongst blood ...

    African Journals Online (AJOL)

    Background: Hepatitis C virus (HCV) is one of the most common transfusion transmissible infections hence the introduction of routine screening for its antibodies in blood donors in most blood banks. Methods: This was a retrospective study in which the blood donor screening register for all intending donors were reviewed ...

  17. Lung perfusion in hemorrhagic shock of rats. The effects of resuscitation with whole blood, saline or hes 6%

    Energy Technology Data Exchange (ETDEWEB)

    Turhanoglu, S.; Kaya, S.; Kararmaz, A.; Turhanoglu, A.D. [Dicle Univ., Diyarbakir (Turkey). Medical School

    2001-12-01

    This study was undertaken to determine the effects of various resuscitation regimens on lung perfusion following resuscitation from hemorrhagic shock. Fourty male Sprague-Dawley rats (250-300 g) were used. The rats were divided randomly into four groups (n=10 for each) and were sedated with intramuscular ketamine (100 mg/kg). We measured blood pressure, rectal temperature and lung perfusion using radioscintigraphy with a technetium colloid indicator. The systolic blood pressure was decreased 75% by removing blood via v. jugularis in the first three groups and group 4 was accepted as the control group, and blood volume was not diminished. Then the first three groups were resuscitated with autologous blood containing 125 units heparine/ml in group 1, saline in group 2, and hydroxyethyl starch (HES) 6% in group 3. After the correction of hypovolemia, all animals were injected 100 Bg (0.1 cc) technetium 99m macroaggregated albumin ({sup 99m}Tc MAA) via penil vein. After injection of {sup 99m}Tc MAA, 3 minutes fixed images were detected by a {gamma} camera in posterior position at 15 minutes and 5 hours. {sup 99m}Tc MMA ''wash out'' rate in lung was determined quantitatively at 5 hours. Compared to a control group, lung perfusion was decreased significantly in groups resuscitated with saline, and HES 6% while perfusion was restored with autologous blood. We conclude that heparinized autologous blood saved lung capillary circulation in hemorrhagic shock in rats. (author)

  18. Lung perfusion in hemorrhagic shock of rats. The effects of resuscitation with whole blood, saline or hes 6%

    International Nuclear Information System (INIS)

    Turhanoglu, S.; Kaya, S.; Kararmaz, A.; Turhanoglu, A.D.

    2001-01-01

    This study was undertaken to determine the effects of various resuscitation regimens on lung perfusion following resuscitation from hemorrhagic shock. Fourty male Sprague-Dawley rats (250-300 g) were used. The rats were divided randomly into four groups (n=10 for each) and were sedated with intramuscular ketamine (100 mg/kg). We measured blood pressure, rectal temperature and lung perfusion using radioscintigraphy with a technetium colloid indicator. The systolic blood pressure was decreased 75% by removing blood via v. jugularis in the first three groups and group 4 was accepted as the control group, and blood volume was not diminished. Then the first three groups were resuscitated with autologous blood containing 125 units heparine/ml in group 1, saline in group 2, and hydroxyethyl starch (HES) 6% in group 3. After the correction of hypovolemia, all animals were injected 100 Bg (0.1 cc) technetium 99m macroaggregated albumin ( 99m Tc MAA) via penil vein. After injection of 99m Tc MAA, 3 minutes fixed images were detected by a γ camera in posterior position at 15 minutes and 5 hours. 99m Tc MMA ''wash out'' rate in lung was determined quantitatively at 5 hours. Compared to a control group, lung perfusion was decreased significantly in groups resuscitated with saline, and HES 6% while perfusion was restored with autologous blood. We conclude that heparinized autologous blood saved lung capillary circulation in hemorrhagic shock in rats. (author)

  19. Hepatic blood flow determination. A comparison of 99mTc-diethyl-IDA and indocyanine green as hepatic blood flow indicators in man

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Winkler, K

    1987-01-01

    99mTc-diethyl-acetanilide-iminodiacetic acid (IDA) was compared with indocyanine green (ICG) as an indicator of hepatic blood flow (HBF). Twelve subjects (8 with cirrhosis, 2 with fatty liver, one with pancreatitis, and one with intestinal angina) were studied during hepatic vein catheterization...

  20. Studies on the hepatic hemodynamics of the patients with fatty liver by hepatic blood flow mapping

    International Nuclear Information System (INIS)

    Kubo, Shuichi; Okajima, Tugio; Yamazaki, Yasurou

    1991-01-01

    To investigate intrahepatic hemodynamics of the patients with fatty liver, the time to reach maximal enhancement (PT) of every 3 x 3 pixel was depicted by a gray scale throughout an area of maximal horizontal slice of CT of the liver to obtain blood flow mapping of the liver, and compared with those of normal, chronic hepatitis and cirrhosis. Mottles of deep gray, light gray or black pixels were distributed throughout the liver slice of fatty liver. Although the mean PT of a ROI of fatty liver was longer than normal and shorter than that of cirrhosis and the same as that of chronic hepatitis, the map of fatty liver was different from that of chronic hepatitis. When the distribution of PT was expressed by their histogram, it was known that PT of fatty liver had a wider range than that of chronic hepatitis. The range was the same as that of cirrhosis. In one case of fatty liver, the deep gray pixels was increased when fatty infiltration of the liver was improved. It was concluded that the intrahepatic blood flow of fatty liver was impaired in a way not similar to chronic hepatitis or liver cirrhosis, which could be clearly seen by hepatic blood flow mapping, and which seemed to be reversible with the improvement of fatty liver. (author)

  1. Hepatic blood flow with colloidal 198Au in the diagnosis of chronic hepatitis in children

    International Nuclear Information System (INIS)

    Marian, L.; Szantay, V.

    1975-01-01

    Tracer quantities of colloidal 198 Au were used to estimate the hepatic blood flow in normal children and in children with active or progressive chronic hepatitis and also to obtain scintigrams of the liver. In active chronic hepatitis a significant decrease in HBF values was observed, suggesting that the method may be used as a diagnostic criterion which is superior to hepatic scintigraphy. In progressive chronic hepatitis HBF values even lower than those in active hepatitis were observed. Together with more characteristic clinical findings and abnormal results of biochemical function tests, they underline the value of the method in estimating the severity and the evolution of the disease. (orig.) [de

  2. Fundamental supply of skin blood flow in the Chinese Han population: Measurements by a full-field laser perfusion imager.

    Science.gov (United States)

    Fei, W; Xu, S; Ma, J; Zhai, W; Cheng, S; Chang, Y; Wang, X; Gao, J; Tang, H; Yang, S; Zhang, X

    2018-05-08

    Skin blood flow is believed to link with many diseases, and shows a significant heterogeneity. There are several papers on basal cutaneous microcirculation perfusion in different races, while the data in Chinese is vacant. The aim was to establish the database of absolute fundamental supply of skin blood flow in the Chinese Han population. With a full-field laser perfusion imager (FLPI), the skin blood flow can be quantified. Cutaneous perfusion values were determined in 17 selected skin areas in 406 healthy participants aged between 20 and 80 years (mean 35.05 ± 11.33). Essential parameters such as weight, height were also measured and values of BMI were calculated. The perfusion values were reported in Arbitrary Perfusion Units (APU). The highest cutaneous perfusion value fell on eyelid (931.20 ± 242.59 in male and 967.83 ± 225.49 in female), and pretibial had the lowest value (89.09 ± 30.28 in male and 85.08 ± 33.59 in female). The values were higher in men than women on the bank of fingertips, nose, forehead, cheek, neck and earlobe (P < .05). Perfusion values on stretch and flexion side of forearm had negative correlation with age (P = .01 and P = 4.88 × 10 -3 , respectively) in male. Abdomen was negatively correlated with BMI in both gender (P = .02, respectively). Skin blood flow values vary with skin regions. There is a tendency to measure higher perfusion values in men than in women. And the values are irrelevant with age or BMI. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Hepatic blood flow and splanchnic oxygen consumption in patients with liver failure. Effect of high-volume plasmapheresis.

    Science.gov (United States)

    Clemmesen, J O; Gerbes, A L; Gülberg, V; Hansen, B A; Larsen, F S; Skak, C; Tygstrup, N; Ott, P

    1999-02-01

    Liver failure represents a major therapeutic challenge, and yet basic pathophysiological questions about hepatic perfusion and oxygenation in this condition have been poorly investigated. In this study, hepatic blood flow (HBF) and splanchnic oxygen delivery (DO2, sp) and oxygen consumption (VO2,sp) were assessed in patients with liver failure defined as hepatic encephalopathy grade II or more. Measurements were repeated after high-volume plasmapheresis (HVP) with exchange of 8 to 10 L of plasma. HBF was estimated by use of constant infusion of D-sorbitol and calculated according to Fick's principle from peripheral artery and hepatic vein concentrations. In 14 patients with acute liver failure (ALF), HBF (1.78 +/- 0.78 L/min) and VO2,sp (3.9 +/- 0.9 mmol/min) were higher than in 11 patients without liver disease (1.07 +/- 0.19 L/min, P HVP, HBF increased from 1.67 +/- 0.72 to 2.07 +/- 1.11 L/min (n=11) in ALF, and from 1.89 +/- 1.32 to 2.34 +/- 1.54 L/min (n=7) in AOCLD, P HVP. Blood flow was redirected to the liver as the systemic vascular resistance index increased (1,587 +/- 650 vs. 2, 020 +/- 806 Dyne. s. cm-5. m2, P HVP, but as cardiac output increased from 9.1 +/- 2.8 to 10.1 +/- 2.9 L/min (P HVP (n=18), DO2,sp increased by 15% (P HVP. Changes of ET-1 were positively correlated with changes in HBF (P HVP (P HVP did not correlate. Our data suggest that liver failure is associated with increased HBF and VO2, sp. HVP further increased HBF and DO2,sp but VO2,sp was unchanged, indicating that splanchnic hypoxia was not present.

  4. Hepatic sinusoid is not well-stirred: estimation of the degree of axial mixing by analysis of lobular concentration gradients formed during uptake of thyroxine by the perfused rat liver

    International Nuclear Information System (INIS)

    Weisiger, R.A.; Mendel, C.M.; Cavalieri, R.R.

    1986-01-01

    Two general models have been proposed for predicting the effects of metabolism, protein binding, and plasma flow on the removal of drugs by the liver. These models differ in the degree of plasma mixing assumed to exist within each hepatic sinusoid. The venous equilibrium model treats the sinusoid as a single well-stirred compartment, whereas the sinusoidal model effectively breaks up the sinusoid into a large number of sequentially perfused compartments which do not exchange their contents except through plasma flow. As a consequence, the sinusoidal model, but not the venous equilibrium model, predicts that the concentration of highly extracted drugs will decline as the plasma flows through the hepatic lobule. To determine which of these alternative models best describes the hepatic uptake process, we looked for evidence that concentration gradients are formed during the uptake of [ 125 I]thyroxine by the perfused rat liver. Autoradiography of tissue slices after perfusion of the portal vein at physiologic flow rates with protein-free buffer containing [ 125 I]thyroxine demonstrated a rapid exponential fall in grain density with distance from the portal venule, declining by half for each 8% of the mean length of the sinusoid. Reversing the direction of perfusate flow reversed the direction of the autoradiographic gradients, indicating that they primarily reflect differences in the concentration of thyroxine within the hepatic sinusoids rather than differences in the uptake capacity of portal and central hepatocytes. Analysis of the data using models in which each sinusoid was represented by different numbers of sequentially perfused compartments (1-20) indicated that at least eight compartments were necessary to account for the magnitude of the gradients seen

  5. Hepatitis B and C Viral Infections Among Blood Donors from Rural ...

    African Journals Online (AJOL)

    Hepatitis B and C Viral Infections Among Blood Donors from Rural Ghana. B Nkrumah, M Owusu, HO Frempong, P Averu. Abstract. Objective: To investigate the prevalence of Hepatitis B and C infections and co-infections among blood donors in a rural community of Ghana. Design: A retrospective study. Method: Samples ...

  6. Primary immunization-like response without hepatitis following transfusion of HBeAg-positive blood

    DEFF Research Database (Denmark)

    Gluud, C; Aldershvile, J; Kryger, P

    1983-01-01

    An accidental transfusion of hepatitis B surface antigen (HBsAg) and hepatitis B e antigen (HBeAg) positive whole blood was given to a 19-yr-old male, bleeding after tonsillectomy. Serum obtained from the patient before the transfusion revealed no hepatitis B antigens or antibodies. After...... the transfusion the patient became HBsAg-positive, cleared this antigen and developed antibodies to both HBsAg and HBeAg. The transfusion blood was positive for total antibody and IgM antibody to hepatitis B core antigen (HBcAg). The patient's blood became positive for these antibodies after the transfusion...

  7. Increased brainstem perfusion, but no blood-brain barrier disruption, during attacks of migraine with aura.

    Science.gov (United States)

    Hougaard, Anders; Amin, Faisal M; Christensen, Casper E; Younis, Samaira; Wolfram, Frauke; Cramer, Stig P; Larsson, Henrik B W; Ashina, Messoud

    2017-06-01

    See Moskowitz (doi:10.1093/brain/awx099) for a scientific commentary on this article.The migraine aura is characterized by transient focal cortical disturbances causing dramatic neurological symptoms that are usually followed by migraine headache. It is currently not understood how the aura symptoms are related to the headache phase of migraine. Animal studies suggest that cortical spreading depression, the likely mechanism of migraine aura, causes disruption of the blood-brain barrier and noxious stimulation of trigeminal afferents leading to activation of brainstem nuclei and triggering of migraine headache. We used the sensitive and validated technique of dynamic contrast-enhanced high-field magnetic resonance imaging to simultaneously investigate blood-brain barrier permeability and tissue perfusion in the brainstem (at the level of the lower pons), visual cortex, and brain areas of the anterior, middle and posterior circulation during spontaneous attacks of migraine with aura. Patients reported to our institution to undergo magnetic resonance imaging during the headache phase after presenting with typical visual aura. Nineteen patients were scanned during attacks and on an attack-free day. The mean time from attack onset to scanning was 7.6 h. We found increased brainstem perfusion bilaterally during migraine with aura attacks. Perfusion also increased in the visual cortex and posterior white matter following migraine aura. We found no increase in blood-brain barrier permeability in any of the investigated regions. There was no correlation between blood-brain barrier permeability, brain perfusion, and time from symptom onset to examination or pain intensity. Our findings demonstrate hyperperfusion in brainstem during the headache phase of migraine with aura, while the blood-brain barrier remains intact during attacks of migraine with aura. These data thus contradict the preclinical hypothesis of cortical spreading depression-induced blood-brain barrier

  8. Blood temperature and perfusion to exercising and non-exercising human limbs

    DEFF Research Database (Denmark)

    González-Alonso, José; Calbet, José Al; Boushel, Robert

    2015-01-01

    Temperature-sensitive mechanisms may contribute to blood flow regulation, but the influence of temperature on perfusion to exercising and non-exercising human limbs is not established. Blood temperature (TB ), blood flow and oxygen uptake (VO2 ) in the legs and arms were measured in 16 healthy...... humans during 90 min of leg and arm exercise and during exhaustive incremental leg or arm exercise. During prolonged exercise, leg blood flow (LBF) was 4-fold higher than arm blood flow (ABF) in association with higher TB and limb VO2 . Leg and arm vascular conductance during exercise compared to rest...... was related closely to TB (R(2) = 0.91; P exercise, LBF increased in association with elevations in TB and limb VO2 whereas ABF, arm TB and VO2 remained largely unchanged. During...

  9. A case of Hepatitis E in a blood donor

    Directory of Open Access Journals (Sweden)

    Anita A Tendulkar

    2015-01-01

    Full Text Available The threat of hepatitis E is being felt in blood banks in recent times. The disease is usually self-limiting, but may progress to a fulminant fatal form. We report a unique case of a hepatitis E virus (HEV-positive asymptomatic blood donor who later developed jaundice and informed the blood bank. A blood donor passed all eligibility criteria tests and donated blood. After 20 days, the blood bank was informed by the donor that he had developed vomiting and jaundice 1 day postdonation. He was investigated by a local laboratory 1 day postdonation for liver profile, which was high. There had been a major outbreak in his community of similar symptoms during the same period. HEV IgM antibody by enzyme-linked immunosorbent assay was positive. Silent infections may be lurking in apparently healthy donors. Donors need to be encouraged to revert in case of any significant developments after donation and maintain open channels of communication.

  10. Perfusion MRI (dynamic susceptibility contrast imaging) with different measurement approaches for the evaluation of blood flow and blood volume in human gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, H. (Den Sundhedsfaglige Kandidatuddannelse, Aarhus Universitet Bygning 1264, Aarhus (Denmark); University College Nordjylland, Aalborg (Denmark)), Email: hnt@ucn.dk; Steffensen, E. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark)); Larsson, E. M. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Uppsala University Hospital, Department of Radiology, Uppsala (Sweden))

    2012-02-15

    Background. Perfusion magnetic resonance imaging (MRI) is increasingly used in the evaluation of brain tumors. Relative cerebral blood volume (rCBV) is usually obtained by dynamic susceptibility contrast (DSC) MRI using normal appearing white matter as reference region. The emerging perfusion technique arterial spin labelling (ASL) presently provides measurement only of cerebral blood flow (CBF), which has not been widely used in human brain tumor studies. Purpose. To assess if measurement of blood flow is comparable with measurement of blood volume in human biopsy-proven gliomas obtained by DSC-MRI using two different regions for normalization and two different measurement approaches. Material and Methods. Retrospective study of 61 patients with different types of gliomas examined with DSC perfusion MRI. Regions of interest (ROIs) were placed in tumor portions with maximum perfusion on rCBF and rCBV maps, with contralateral normal appearing white matter and cerebellum as reference regions. Larger ROIs were drawn for histogram analyses. The type and grade of the gliomas were obtained by histopathology. Statistical comparison was made between diffuse astrocytomas, anaplastic astrocytomas, and glioblastomas. Results. rCBF and rCBV measurements obtained with the maximum perfusion method were correlated when normalized to white matter (r = 0.60) and to the cerebellum (r = 0.49). Histogram analyses of rCBF and rCBV showed that mean and median values as well as skewness and peak position were correlated (0.61 < r < 0.93), whereas for kurtosis and peak height, the correlation coefficient was about 0.3 when comparing rCBF and rCBV values for the same reference region. Neither rCBF nor rCBV quantification provided a statistically significant difference between the three types of gliomas. However, both rCBF and rCBV tended to increase with tumor grade and to be lower in patients who had undergone resection/treatment. Conclusion. rCBF measurements normalized to white matter

  11. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  12. Blood group ascription as a genetic marker of hepatic hemangioma

    International Nuclear Information System (INIS)

    Polysalov, V.N.; Tarazov, P.G.

    1992-01-01

    There is no single point of view on pathogenesis of hemangiomas. The authors investigated the ABO blood types in 52 patients with hepatic hemangiomas (Group 1) and 1000 control patients (Group 2). The character of changes in the liver was established by means of reontgenoradionuclide investigation methods. The study demonstrated 61.5 % of the A blood type among the patients of Group 1. This was significantly higher than in the Group 2 and representative groups from literature (P < 0.001). Taking into account that the cells of both blood and blood vessels are formed in embryos through the mesenchyma and the heritability of blood group antigens, it is supposed that the results obtained support the genetic determination theory of pathogenesis of hepatic hemangioamas

  13. Hepatitis C and blood transfusion among children attending the ...

    African Journals Online (AJOL)

    Background: Hepatitis C virus (HCV) accounts for 90% of post-transfusion hepatitis. In Uganda, there has been limited research of prevalence of HCV among sickle cell anaemia (SS) patients, a group at risk for multiple transfusions. Objectives: To establish prevalence of HCV infection and determine whether blood ...

  14. Actions of p-synephrine on hepatic enzyme activities linked to carbohydrate metabolism and ATP levels in vivo and in the perfused rat liver.

    Science.gov (United States)

    Maldonado, Marcos Rodrigues; Bracht, Lívia; de Sá-Nakanishi, Anacharis Babeto; Corrêa, Rúbia Carvalho Gomes; Comar, Jurandir Fernando; Peralta, Rosane Marina; Bracht, Adelar

    2018-01-01

    p-Synephrine is one of the main active components of the fruit of Citrus aurantium (bitter orange). Extracts of the bitter orange and other preparations containing p-synephrine have been used worldwide to promote weight loss and for sports performance. The purpose of the study was to measure the action of p-synephrine on hepatic enzyme activities linked to carbohydrate and energy metabolism and the levels of adenine mononucleotides. Enzymes and adenine mononucleotides were measured in the isolated perfused rat liver and in vivo after oral administration of the drug (50 and 300 mg/kg) by using standard techniques. p-Synephrine increased the activity of glycogen phosphorylase in vivo and in the perfused liver. It decreased, however, the activities of pyruvate kinase and pyruvate dehydrogenase also in vivo and in the perfused liver. p-Synephrine increased the hepatic pools of adenosine diphosphate and adenosine triphosphate. Stimulation of glycogen phosphorylase is consistent with the reported increased glycogenolysis in the perfused liver and increased glycemia in rats. The decrease in the pyruvate dehydrogenase activity indicates that p-synephrine is potentially capable of inhibiting the transformation of carbohydrates into lipids. The capability of increasing the adenosine triphosphate-adenosine diphosphate pool indicates a beneficial effect of p-synephrine on the cellular energetics. Copyright © 2017 John Wiley & Sons, Ltd.

  15. The relationship between red blood cell deformability metrics and perfusion of an artificial microvascular network.

    Science.gov (United States)

    Sosa, Jose M; Nielsen, Nathan D; Vignes, Seth M; Chen, Tanya G; Shevkoplyas, Sergey S

    2014-01-01

    The ability of red blood cells (RBC) to undergo a wide range of deformations while traversing the microvasculature is crucial for adequate perfusion. Interpretation of RBC deformability measurements performed in vitro in the context of microvascular perfusion has been notoriously difficult. This study compares the measurements of RBC deformability performed using micropore filtration and ektacytometry with the RBC ability to perfuse an artificial microvascular network (AMVN). Human RBCs were collected from healthy consenting volunteers, leukoreduced, washed and exposed to graded concentrations (0-0.08%) of glutaraldehyde (a non-specific protein cross-linker) and diamide (a spectrin-specific protein cross-linker) to impair the deformability of RBCs. Samples comprising cells with two different levels of deformability were created by adding non-deformable RBCs (hardened by exposure to 0.08% glutaraldehyde) to the sample of normal healthy RBCs. Ektacytometry indicated a nearly linear decline in RBC deformability with increasing glutaraldehyde concentration. Micropore filtration showed a significant reduction only for concentrations of glutaraldehyde higher than 0.04%. Neither micropore filtration nor ektacytometry measurements could accurately predict the AMVN perfusion. Treatment with diamide reduced RBC deformability as indicated by ektacytometry, but had no significant effect on either micropore filtration or the AMVN perfusion. Both micropore filtration and ektacytometry showed a linear decline in effective RBC deformability with increasing fraction of non-deformable RBCs in the sample. The corresponding decline in the AMVN perfusion plateaued above 50%, reflecting the innate ability of blood flow in the microvasculature to bypass occluded capillaries. Our results suggest that in vitro measurements of RBC deformability performed using either micropore filtration or ektacytometry may not represent the ability of same RBCs to perfuse microvascular networks. Further

  16. Tc-99m macroaggregate albumin perfusion studies in the therapeutically embolized liver

    International Nuclear Information System (INIS)

    Hall, J.T.; Kim, E.E.; Charnsangavej, C.; Haynie, T.P.; Wallace, S.

    1988-01-01

    This paper discusses the authors' study of 15 patients who underwent 21 hepatic arterial chemoembolizations and hepatic arterial chemotherapy infusions. The arteriograms and the hepatic perfusion studies using Tc-99m macroaggregates of human serum albumin (MAA) particles were reviewed and correlated. Early perfusion studies (within 4 hours of embolization) often revealed flow reversal or MAA reflux into an undesirable location. Scans obtained at 24 hours revealed restoration of flow to the embolized lobe, confirming the proper position of the catheter for hepatic arterial chemotherapy infusion

  17. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients.

    Science.gov (United States)

    Kanadani, Fabio N; Figueiredo, Carlos R; Miranda, Rafaela Morais; Cunha, Patricia Lt; M Kanadani, Tereza Cristina; Dorairaj, Syril

    2015-01-01

    Glaucomatous neuropathy can be a consequence of insufficient blood supply, increase in intraocular pressure (IOP), or other risk factors that diminish the ocular blood flow. To determine the ocular perfusion pressure (OPP) in normal and systemic hypertensive patients. One hundred and twenty-one patients were enrolled in this prospective and comparative study and underwent a complete ophthalmologic examination including slit lamp examination, Goldmann applanation tonometry, stereoscopic fundus examination, and pulsatile ocular blood flow (POBF) measurements. The OPP was calculated as being the medium systemic arterial pressure (MAP) less the IOP. Only right eye values were considered for calculations using Student's t-test. The mean age of the patients was 57.5 years (36-78), and 68.5% were women. There was a statistically significant difference in the OPP of the normal and systemic hypertensive patients (p cite this article: Kanadani FN, Figueiredo CR, Miranda RM, Cunha PLT, Kanadani TCM, Dorairaj S. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients. J Curr Glaucoma Pract 2015;9(1):16-19.

  18. Development of extrahepatic arterial blood supply to the liver during hepatic arterial infusion chemotherapy

    International Nuclear Information System (INIS)

    Seki, H.; Kimura, M.; Yoshimura, N.; Yamamoto, S.; Ozaki, T.; Sakai, K.

    1998-01-01

    The aim of this study was to evaluate the correlation of development of the collateral circulation to the liver during hepatic arterial infusion chemotherapy (HAIC) with the presence of hepatic tumours adjacent to the hepatic surface, and with pretreatment occlusion of aberrant hepatic arteries. In 102 patients with unresectable malignant hepatic tumours treated with HAIC using an implantable port system, development of collaterals to the liver was assessed with CT arteriography using the implantable port and pre- and postoperative angiography. Aberrant hepatic arteries, if present, were occluded prior to treatment for hepatic arterial redistribution. Collaterals to the liver were seen in 29 patients, who had 35 areas with collateral perfusion: 22 areas were in the right posterosuperior area, 6 in the left peripheral area and 7 in the right or left lobar area. Collaterals were revealed more frequently in patients with hepatic tumours adjacent to the hepatic surface than in those without hepatic tumours in peripheral areas in the liver (p < 0.0001). In addition, collaterals developed more frequently in patients with an aberrant hepatic arterial anatomy compared with those with conventional anatomy (p = 0.0007). Our results indicated that patients with hepatic tumours adjacent to the hepatic surface and with pretreatment occlusion of aberrant hepatic arteries had the potential to develop collaterals to the liver during HAIC. (orig.)

  19. Hepatitis C and blood transfusion among children attending the ...

    African Journals Online (AJOL)

    EB

    2013-06-02

    Jun 2, 2013 ... Background: Hepatitis C virus (HCV) accounts for 90% of post-transfusion hepatitis. In Uganda, there has been limited research ... Of these, 159 (65%) had a history of blood transfusion. Among the transfused, five patients were .... 6.4 computer software package. Analysis was done using SPSS Version 11,.

  20. Epidemiology of Hepatitis C Virus in the private blood banking ...

    African Journals Online (AJOL)

    Background: Hepatitis C Virus (HCV) is an agent of Transfusion Transmissible Infection (TTI) which serves as a threat to blood safety and sufficiency of blood and blood products supply. Objectives: This study aimed at determining the distribution patterns of HCV among potential blood donors in a private Blood Bank in ...

  1. Prediction of residual lung function after lung surgery, and examination of blood perfusion in the pre- and postoperative lung using three-dimensional SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Shimatani, Shinji [Toho Univ., Tokyo (Japan). School of Medicine

    2001-01-01

    In order to predict postoperative pulmonary function after lung surgery, preoperative {sup 99m}Tc-macroaggregated albumin (MAA) lung perfusion scans with single-photon emission computed tomography (SPECT) were performed. Spirometry was also performed before and 4-6 months after surgery in 40 patients. In addition, changes in blood perfusion in the pre- and postoperative lung were examined by postoperative lung perfusion scans in 18 of the 40 patients. We measured the three-dimensional (3-D) imaging volume of the operative and contralateral lungs using the volumes rendering method at blood perfusion thresholds of 20, 50 and 75%, utilizing {sup 99m}Tc-MAA lung perfusion, and predicted pulmonary function by means of the measured volumes. We examined the correlation between predicted and the measured values of postoperative pulmonary function, forced vital capacity (FVC) and forced expiratory volume in one second (FEV{sub 1.0}). The correlation between FEV{sub 1.0} predicted by SPECT (threshold 50%) and measured postoperative lung function resembled that between lung function predicted by the standard planar method and measured FEV{sub 1.0} in the lobectomy group. We then examined the ratios of both pre- and postoperative blood perfusion volumes obtained using 3-D imaging at lung perfusion threshold ranges of 10% each (PV20-29, PV30-39) to pre- and postoperative total perfusion (PV20-100). In the lobectomy group, the postoperative PV20-29/PV20-100 value was significantly higher for the operative side lung than the preoperative PV20-29/PV20-100 value, and the postoperative PV50-59, 60-69, 70-79, 80-89 and 90-100/PV20-100 values were significantly lower than the respective preoperative values. However, in the contralateral lung, the respective pre- and postoperative PV/PV20-100 values were almost identical. These findings suggest that the rate of low blood perfusion increased while the rate of middle to high perfusion decreased in the lobectomy group in the operative

  2. Evaluation of RI images of hepatic blood flow using Tc-99m PMT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hiromichi; Iwasaki, Naoya; Ichikawa, Kesato

    1988-03-01

    To evaluate the clinical significance of RI images of hepatic blood flow using Tc-99m-PMT, analysis of the RI images and estimation of hepatic blood flow were carried out in patients with various liver diseases (37 cases). After intravenous injection of Tc-99m-PMT, hepatic accumulation curve of ROI positioned at whole liver area and time activity curve of ROI positioned at celiac artery were obtained through scintillation camera images with the computer-analysed system. Hepatic blood flow coefficient (K) was calculated from the hepatic accumulation curve. Based on the differential curve calculated from the time activity curve, chronological images of arterial, portal, parenchymal and saturated parenchymal phases were obtained. Results ; 1) K was 0.50 + 0.04, 0.35 + 0.02 and 0.26 + 0.04/min in normal type, CH type and LC type respectively. These coefficients well correlated with clinical severity of hepatic diseases. 2) Perfusional phase images of the liver became poorer in accordance with progression of liver disease, while images of spleen, portal venous system and collateral channels were more clearly obtained in liver cirrhosis. This method was shown to have a potential to understanding of severity of liver disease and hepatic blood flow dynamics.

  3. Declining prevalence of hepatitis E antibodies among Danish blood donors

    DEFF Research Database (Denmark)

    Holm, Dorte K; Moessner, Belinda K; Engle, Ronald E

    2015-01-01

    BACKGROUND: The increasing incidence of reported hepatitis E cases in Europe has focused attention on hepatitis E virus (HEV) and the risk of transfusion-transmitted hepatitis E. The aim of this study was to investigate the prevalence of antibodies to HEV (anti-HEV) among Danish blood donors...... in 2013 and to compare it to previous studies in Denmark. In addition we wanted to compare the relative reactivity of two different assays. STUDY DESIGN AND METHODS: Samples from 504 blood donors were collected and analyzed for anti-HEV with an in-house assay developed at the National Institutes of Health...... (NIH). In addition the samples were analyzed with the Wantai anti-HEV assay. Demographic information and possible HEV exposure was collected by self-administered questionnaire. RESULTS: Using the NIH assay the prevalence of anti-HEV among Danish blood donors was 10.7% and with the Wantai assay...

  4. Management of isolated nonresectable liver metastases in colorectal cancer patients: a case-control study of isolated hepatic perfusion with melphalan versus systemic chemotherapy

    NARCIS (Netherlands)

    van Iersel, L. B. J.; Koopman, M.; van de Velde, C. J. H.; Mol, L.; van Persijn van Meerten, E. L.; Hartgrink, H. H.; Kuppen, P. J. K.; Vahrmeijer, A. L.; Nortier, J. W. R.; Tollenaar, R. A. E. M.; Punt, C.; Gelderblom, H.

    2010-01-01

    To compare the median overall survival of patients with isolated nonresectable liver metastases in comparable groups of patients treated with either isolated hepatic perfusion (IHP) with melphalan or systemic chemotherapy. Colorectal cancer patients with isolated liver metastases, who underwent IHP,

  5. Relation between blood clearance and hepatic uptake of sup 99m Tc-phytate in rats with hepatic injury

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Hiroshi; Hisano, Tomoyuki; Kohno, Masahiro (Yamaguchi University, Ube (Japan). Faculty of Agriculture)

    1989-10-01

    The relation among the blood clearance of {sup 99m}Tc-phytake ({sup 99m}Tc-P), the hepatic uptake of {sup 99m}Tc-P and the severity of hepatic injury was investigated by using the rats with carbon tetrachloride (CCL{sub 4}), D-galactosamine (Gal N), alpha-naphthylisothiocyanate (ANIT) or DL-ethionine (EthN) induced hepatic injury. After the administration of CCL{sub 4}, GalN or ANIT, serum GPT activity increased significantly with the increase of dose level, and the degree of this increase was in the order: GalN>CCl{sub 4}>ANIT. However, the mild increase in serum GPT activity was observed after EthN administration. The blood clearance rate of {sup 99m}Tc-P and the hepatic uptake ratio of {sup 99m}Tc-P decreased with the increase of dose level after CCl{sub 4}, GalN or ANIT administration, but significant changes were not found after EthN administration. The degree of decrease in the blood clearance rate of {sup 99m}Tc-P was in the order: GalNapproxCCl{sub 4}>ANIT, and the degree of decrease in the hepatic uptake ratio of {sup 99m}Tc-P was in the order: GalNapproxCCl{sub 4}>ANIT. These results suggest that the disorder in the hepatocytes may be one of causes for inducing the decrease in the hepatic uptake of {sup 99m}Tc-P, and the consequence of this decrease may induce the decrease in the blood clearance of {sup 99m}Tc-P. (author).

  6. Increased sinusoidal volume and solute extraction during retrograde liver perfusion

    International Nuclear Information System (INIS)

    Bass, N.M.; Manning, J.A.; Weisiger, R.A.

    1989-01-01

    Retrograde isolated liver perfusion has been used to probe acinar functional heterogeneity, but the hemodynamic effects of backward flow have not been characterized. In this study, extraction of a long-chain fatty acid derivative, 12-N-methyl-7-nitrobenzo-2-oxa-1,3-diazol-amino stearate (12-NBDS), was greater during retrograde than during anterograde perfusion of isolated rat liver. To determine whether hemodynamic differences between anterograde and retrograde perfused livers could account for this finding, the hepatic extracellular space was measured for both directions of flow by means of [ 14 C]sucrose washout during perfusion as well as by direct measurement of [ 14 C]sucrose entrapped during perfusion. A three- to fourfold enlargement of the total hepatic extracellular space was found during retrograde perfusion by both approaches. Examination of perfusion-fixed livers by light microscopy and morphometry revealed that marked distension of the sinusoids occurred during retrograde perfusion and that this accounts for the observed increase in the [ 14 C]sucrose space. These findings support the hypothesis that maximum resistance to perfusate flow in the isolated perfused rat liver is located at the presinusoidal level. In addition, increased transit time of perfusate through the liver and greater sinusoidal surface area resulting from sinusoidal distension may account for the higher extraction of 12-NBDS and possibly other compounds by retrograde perfused liver

  7. Double-Balloon Catheter for Isolated Liver Perfusion: An Experimental Study

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Bergqvist, Lennart; Harnek, Jan

    2001-01-01

    Purpose: Further development of a previously described interventional method for isolated liver perfusion (ILP) with a new double-lumen balloon catheter, and evaluation of the side-effects of such isolation.Methods: In six pigs a double-balloon occlusion catheter was placed via the transjugular approach with its tip in the portal vein. One of the balloons was positioned in the inferior vena cava (IVC), cranial to the origin of the hepatic veins and the other balloon in the portal vein. By the transfemoral approach, a single-balloon occlusion catheter was placed in the IVC caudal to the origin of the hepatic veins. A third catheter was placed by the transfemoral route with the occlusion balloon in the proper hepatic artery. After inflation of all balloons 99 Tc m -labelled human serum albumin was recirculated through the liver. The isolation was evaluated by repeated measurement of radioactivity levels in peripheral blood. Laboratory tests of liver and pancreas function, and hemoglobin, were taken before, at the end of, and 3 days after the procedure. Blood gases were tested at the beginning and end of the procedure.Results: One pig died during the procedure due to technical failure and was excluded from the study. In the other pigs leakage from the isolated liver to the systemic circulation increased slowly, up to 9.7% (mean) during 30 min of recirculation of the perfusate through the liver. Laboratory tests were normal in all pigs except insignificant acidosis directly after the procedure and the slight elevation of s-ALAT after 3 days.Conclusions: Only minor leakage from the liver to the systemic circulation was noted during ILP performed with a new, double-balloon catheter. There were no serious side effects

  8. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Certain, D.A.; Brolio, R.; Salomon, G.C.; Carvalho, N.; Barbosa, Z.L.M.

    1972-01-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin 131 I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions [pt

  9. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Certain, D A; Brolio, R; Salomon, G C [Sao Paulo Univ. (Brazil). Faculdade de Saude Publica; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear; Barbosa, Z L.M. [Associacao dos Sanatorios Populares de Campos do Jordao, Brazil

    1972-10-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin /sup 131/I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions.

  10. Hydrostatic determinants of cerebral perfusion

    International Nuclear Information System (INIS)

    Wagner, E.M.; Traystman, R.J.

    1986-01-01

    We examined the cerebral blood flow response to alterations in perfusion pressure mediated through decreases in mean arterial pressure, increases in cerebrospinal fluid (CSF) pressure, and increases in jugular venous (JV) pressure in 42 pentobarbital anesthetized dogs. Each of these three pressures was independently controlled. Cerebral perfusion pressure was defined as mean arterial pressure minus JV or CSF pressure, depending on which was greater. Mean hemispheric blood flow was measured with the radiolabeled microsphere technique. Despite 30-mm Hg reductions in mean arterial pressure or increases in CSF or JV pressure, CBF did not change as long as the perfusion pressure remained greater than approximately 60 mm Hg. However, whenever perfusion pressure was reduced to an average of 48 mm Hg, cerebral blood flow decreased 27% to 33%. These results demonstrate the capacity of the cerebral vascular bed to respond similarly to changes in the perfusion pressure gradient obtained by decreasing mean arterial pressure, increasing JV pressure or increasing CSF pressure, and thereby support the above definition of cerebral perfusion pressure

  11. ABO/Rh Blood Groups and Risk of HIV Infection and Hepatitis B Among Blood Donors of Abidjan, Côte D'ivoire.

    Science.gov (United States)

    Siransy, Liliane Kouabla; Nanga, Zizendorf Yves; Zaba, Flore Sandrine; Tufa, Nyasenu Yawo; Dasse, Sery Romuald

    2015-09-01

    Hepatitis B and HIV infection are two viral infections that represent real global public health problems. In order to improve their management, some hypotheses suggest that genetic predispositions like ABO and Rh blood groups would influence the occurrence of these diseases. The aim of the present study was to examine the association between ABO and Rhesus blood groups and the susceptibility to HIV infection and hepatitis B. We conducted a cross-sectional and analytical study in a population of voluntary blood donors in the Blood Transfusion Center of Abidjan. All blood donors who donated blood between January and June 2014 were tested for HBs antigen and anti-HIV antibodies (ELISA tests) and were ABO typed. The total number of examined blood donors during this period was 45,538, of which 0.32% and 8.07% were respectively infected with HIV and hepatitis B virus. O-group donors were more infected than non-O donors. Our study is an outline concerning the search for a link between ABO and Rh blood groups and hepatitis B and HIV infection. Further studies should be conducted to confirm the interaction between these two infections and contribute to the search for new therapeutic approaches.

  12. Determination of hepatic blood flow through radioactive colloidal gold in congestive heart foilure

    International Nuclear Information System (INIS)

    Papaleo Netto, M.; Carvalho, N.; Carvalho Filho, E.T.; Forti, N.A.; Giannini, S.D.; Diament, J.; Decourt, L.V.; Chiaverini, R.

    1974-01-01

    Hepatic blood flow as derermined by radioactive colloidal gold and its correlation with total blood valume are studied in 13 patients with predominantly right-side congestive heart failure. During the phase of cardiac compensation, the following events occur: 1) significant decrease of the half-life of the clearance of radioactive colloidal gold and of the total blood volume; 2) increase of the clearance constant of the radioactive substance and of hepatic blood flow; 3) significantion correlation between the clearance constant and the total blood volume [pt

  13. Hepatitis A Virus and Hepatitis E Virus Seroprevalence Among Blood Donors in Tehran, Iran.

    Science.gov (United States)

    Hesamizadeh, Khashayar; Sharafi, Heidar; Keyvani, Hossein; Alavian, Seyed Moayed; Najafi-Tireh Shabankareh, Azar; Sharifi Olyaie, Roghiyeh; Keshvari, Maryam

    2016-01-01

    Hepatitis A virus (HAV) and Hepatitis E virus (HEV) are both transmitted by the fecal-oral route and are known as the leading causes of acute viral hepatitis in the world, especially in developing countries. There is a lack of updated data on HAV and HEV seroprevalence in Iran. The aim of this study was to determine the seroprevalence of HAV and HEV among a group of blood donors in Tehran, Iran. A cross-sectional study was performed from July 2014 to December 2014, on a total of 559 blood donors referred to the Tehran blood transfusion center. The serum samples were tested for antibodies to HAV and HEV, using the enzyme-linked immunosorbent assay. In the present study, 536 (95.9%) cases were male and 23 (4.1%) female with mean age of 38 years. Out of 559 blood donors, 107 (19.1%) were first-time donors, 163 (29.2%) lapsed donors and 289 (51.7%) regular donors. Anti-HAV was found in 395 (70.7%) and anti-HEV in 45 (8.1%) of the blood donors. The HAV and HEV seroprevalence increased by age. There was no significant difference between genders in terms of anti-HAV and anti-HEV status. The HAV and HEV seroprevalence was significantly related to the level of education, where the donors with higher level of education had lower rate of HAV and HEV seroprevalence. The HAV and HEV seroprevalence was significantly higher in regular and lapsed donors than in first-time donors. The present study showed that both HAV and HEV infections are still endemic in Iran.

  14. Single photon emission computed tomographic studies (SPECT) of hepatic arterial perfusion scintigraphy (HAPS) in patients with colorectal liver metastases: improved tumour targetting by microspheres with angiotensin II.

    Science.gov (United States)

    Goldberg, J A; Bradnam, M S; Kerr, D J; McKillop, J H; Bessent, R G; McArdle, C S; Willmott, N; George, W D

    1987-12-01

    As intra-arterial chemotherapy for liver metastases of colorectal origin becomes accepted, methods of further improving drug delivery to the tumour have been devised. Degradable microspheres have been shown to reduce regional blood flow by transient arteriolar capillary block, thereby improving uptake of a co-administered drug, when injected into the hepatic artery. In our study of five patients, we combined hepatic arterial perfusion scintigraphy (HAPS) and SPECT to assess the localization of approximately 1 X 10(5) labelled microspheres of human serum albumin (99Tcm MSA) in tumour. In addition, in three patients, we assessed the effect of an intra-arterial infusion of the vasoactive agent angiotension II during HAPS. Results were interpreted by comparing transaxial slices with corresponding slices of a tin colloid liver-spleen scan. Two of five patients showed good localization of 99Tcm MSA in tumour without an angiotensin II infusion. Of the three patients receiving angiotensin II, all showed good tumour targetting with the vasoconstrictor compared with only one of these three before its use. Thus, hepatic arterial infusion of angiotensin II greatly improves microsphere localization in tumour in some patients with colorectal liver metastases. This technique may be useful in the assessment of tumour targetting before and during locoregional therapy.

  15. Compact Laser Doppler Flowmeter (LDF Fundus Camera for the Assessment of Retinal Blood Perfusion in Small Animals.

    Directory of Open Access Journals (Sweden)

    Marielle Mentek

    Full Text Available Noninvasive techniques for ocular blood perfusion assessment are of crucial importance for exploring microvascular alterations related to systemic and ocular diseases. However, few techniques adapted to rodents are available and most are invasive or not specifically focused on the optic nerve head (ONH, choroid or retinal circulation. Here we present the results obtained with a new rodent-adapted compact fundus camera based on laser Doppler flowmetry (LDF.A confocal miniature flowmeter was fixed to a specially designed 3D rotating mechanical arm and adjusted on a rodent stereotaxic table in order to accurately point the laser beam at the retinal region of interest. The linearity of the LDF measurements was assessed using a rotating Teflon wheel and a flow of microspheres in a glass capillary. In vivo reproducibility was assessed in Wistar rats with repeated measurements (inter-session and inter-day of retinal arteries and ONH blood velocity in six and ten rats, respectively. These parameters were also recorded during an acute intraocular pressure increase to 150 mmHg and after heart arrest (n = 5 rats.The perfusion measurements showed perfect linearity between LDF velocity and Teflon wheel or microsphere speed. Intraclass correlation coefficients for retinal arteries and ONH velocity (0.82 and 0.86, respectively indicated strong inter-session repeatability and stability. Inter-day reproducibility was good (0.79 and 0.7, respectively. Upon ocular blood flow cessation, the retinal artery velocity signal substantially decreased, whereas the ONH signal did not significantly vary, suggesting that it could mostly be attributed to tissue light scattering.We have demonstrated that, while not adapted for ONH blood perfusion assessment, this device allows pertinent, stable and repeatable measurements of retinal blood perfusion in rats.

  16. Mastication induces long-term increases in blood perfusion of the trigeminal principal nucleus.

    Science.gov (United States)

    Viggiano, A; Manara, R; Conforti, R; Paccone, A; Secondulfo, C; Lorusso, L; Sbordone, L; Di Salle, F; Monda, M; Tedeschi, G; Esposito, F

    2015-12-17

    Understanding mechanisms for vessel tone regulation within the trigeminal nuclei is of great interest because some headache syndromes are due to dysregulation of such mechanisms. Previous experiments on animal models suggest that mastication may alter neuron metabolism and blood supply in these nuclei. To investigate this hypothesis in humans, arterial spin-labeling magnetic resonance imaging (MRI) was used to measure blood perfusion within the principal trigeminal nucleus (Vp) and in the dorsolateral-midbrain (DM, including the mesencephalic trigeminal nucleus) in healthy volunteers, before and immediately after a mastication exercise consisting of chewing a gum on one side of the mouth for 1 h at 1 bite/s. The side preference for masticating was evaluated with a chewing test and the volume of the masseter muscle was measured on T1-weighted MRI scans. The results demonstrated that the mastication exercise caused a perfusion increase within the Vp, but not in the DM. This change was correlated to the preference score for the side where the exercise took place. Moreover, the basal Vp perfusion was correlated to the masseter volume. These results indicate that the local vascular tone of the trigeminal nuclei can be constitutively altered by the chewing practice and by strong or sustained chewing. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  17. Clinical application of cerebral dynamic perfusion studies

    International Nuclear Information System (INIS)

    DeLand, F.H.

    1975-01-01

    Radionuclide cerebral perfusion studies are assuming a far greater importance in the detection and differential diagnosis of cerebral lesions. Perfusion studies not only contribute to the differential diagnosis of lesions but in certain cases are the preferred methods by which more accurate clinical interpretations can be made. The characteristic blood flow of arterio-venous malformations readily differentiates this lesion from neoplasms. The decreased perfusion or absent perfusion observed in cerebral infarctions is diagnostic without concurrent evidence from static images. Changes in rates and direction of blood flow contribute fundamental information to the status of stenosis and vascular occlusion and, in addition, offer valuable information on the competency and routes of collateral circulation. The degree of cerebral perfusion after cerebral vascular accidents appears to be directly related to patient recovery, particularly muscular function. Cerebral perfusion adds a new parameter in the diagnosis of subdural haematomas and concussion and in the differentiation of obscuring radioactivity from superficial trauma. Although pictorial displays of perfusion blood flow will offer information in most cerebral vascular problems, the addition of computer analysis better defines temporal relationships of regional blood flow, quantitative changes in flow and the detection of the more subtle increases or decreases in cerebral blood flow. The status of radionuclide cerebral perfusion studies has taken on an importance making it the primary modality for the diagnosis of cerebral lesions. (author)

  18. Cerebral blood perfusion after treatment with zolpidem and flumazenil in the baboon.

    Science.gov (United States)

    Clauss, Ralf P; Dormehl, Irene C; Kilian, Elmaré; Louw, Werner K A; Nel, Wally H; Oliver, Douglas W

    2002-01-01

    Previous studies have shown that zolpidem (CAS 82626-48-0) can lead to improved perfusion in damaged brain tissue. Zolpidem belongs to the imidazopyridine chemical class and it illicits its pharmacological action via the gamma-aminobutyric acid (GABA) receptor system through stimulation of particularly the omega 1 receptors and to a lesser extent omega 2 receptors. Previously it was reported that no cerebral blood flow effects were observed in normal baboons after treatment with zolpidem, whereas an asymmetric regional increase in cerebral blood flow was observed in a neurologically abnormal baboon. In this study, the effect of a combination of the benzodiazepine receptor antagonist flumazenil (CAS 78755-81-4) and zolpidem on brain perfusion was examined by the 99mTc-hexamethyl-propylene amine oxime (99mTc-HMPAO) split dose brain single photon emission computed tomography (SPECT). Four normal baboons and the neurologically abnormal baboon from the previous zolpidem study were examined. In the current study the asymmetric changes observed after zolpidem--only treatment in the abnormal baboon was attenuated by flumazenil intervention. A decreased brain blood flow was observed after combination treatment of zolpidem and flumazenil in the normal baboons. The involvement of the omega receptors is suggested by these results. Up- or down-regulation of omega receptors may also contribute to the observed responses in the abnormal baboon and a brain injured patient.

  19. Three-dimensional whole-brain perfused blood volume imaging with multimodal CT for evaluation of acute ischaemic stroke

    International Nuclear Information System (INIS)

    Lu, J.; Zhang, M.; Cao, Y.; Ma, Q.; Chen, J.; Ji, X.; Li, K.

    2011-01-01

    Aim: To determine the diagnostic value of integrating three-dimensional perfused blood volume (3D PBV) with multimodal computed tomography (CT) [non-enhanced CT (NECT), CT perfusion (CTP), and CT angiography (CTA)] in acute ischaemic stroke. Materials and methods: NECT, CTP, and CTA were performed in 25 acute ischaemic stroke patients. The ischaemia detection rate of 3D PBV was compared with the results of baseline NECT and CTP. The correlation of ischaemic lesion volume between 3D PBV, CTP images, and follow-up NECT were analysed. Results: NECT demonstrated ischaemic signs in 12 of 25 patients with proven infarction. CTP maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and time to peak (TTP) all demonstrated perfusion deficits in 21 of 25 patients. However, 3D PBV demonstrated perfusion deficits in all of the 25 patients. Among the 25 patients, a strong correlation was found between PBV and the follow-up NECT infarct (r = 0.858). The correlation between CTP and the follow-up NECT infarct as following: CBF (r = 0.718), CBV (r = 0.785), and TTP (r = 0.569). In 14 thrombolytic patients, strong correlation was found between the ischaemic volume on 3D PBV and follow-up NECT (r = 0.798). Conclusion: In acute stroke patients, the combination of 3D PBV and multimodal CT (NECT, CTP, and CTA) can improve the detection rate of ischaemia and enable assessment of the full extent of ischaemia, which correlates well with follow-up NECT.

  20. Effect of sulfonylureas on hepatic fatty acid oxidation

    International Nuclear Information System (INIS)

    Patel, T.B.

    1986-01-01

    In isolated rat livers perfused with oleic acid (0.1 mM), infusion of tolbutamide or glyburide decreased the rate of ketogenesis in a dose-dependent manner. The inhibition of fatty acid oxidation was maximal at 2.0 mM and 10 μM concentrations of tolbutamide and glyburide, respectively. Neither tolbutamide nor glyburide inhibited ketogenesis in livers perfused with octanoate. The inhibition of hepatic ketogenesis by sulfonylureas was independent of perfusate oleic acid concentration. Additionally, in rat livers perfused with oleic acid in the presence of L-(-)-carnitine (10 mM), submaximal concentrations of tolbutamide and glyburide did not inhibit hepatic ketogenesis. Finally, glyburide infusion into livers perfused with [U- 1 $C]oleic acid (0.1 mM) increased the rate of 14 C label incorporation into hepatic triglycerides by 2.5-fold. These data suggest that both tolbutamide and glyburide inhibit long-chain fatty acid oxidation by inhibition the key regulatory enzyme, carnitine palmitoyltransferase I, most probably by competing with L-(-)-carnitine

  1. Combining functional CT and FDG PET allows the calculation of FDG extraction fraction and hepatic glucose phosphorylation

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, M R [Centre for Medical and Health Physics, Queensland University of Technology (Australia); Wesley Research Institute, QLD (Australia); Miles, K A [Centre for Medical and Health Physics, Queensland University of Technology (Australia); Wesley Research Institute, QLD (Australia); Southern X-ray Clinics, Brisbane [Australia; Keith, C J [Wesley Research Institute, QLD (Australia)

    2002-09-01

    Perfusion data from Functional CT and FDG-PET data may be combined to provide additional information about the uptake of FDG. We have developed methods to calculate FDG extraction fraction in tissues and to quantify hepatic glucose phosphorylation in the liver. Extraction fraction: Functional CT and FDG-PET studies were used to obtain measurements of perfusion and glucose uptake respectively within ten pulmonary nodules. The net influx constant (Ki) was determined from SUV measurements for each lung mass Extraction fraction (E) for each mass lesion was determined from: E=Ki/(Px[1-Hct]). A pixel by pixel calculation allowed generation of extraction fraction maps. The extraction fraction measurements ranged (median) from 0.6% to 4.81% (2.7%). The values for a benign nodule and an organising pneumonia were 0.6% and 0.71% respectively. Extraction fraction measurements for the malignant nodules ranged from 2.01% to 4.81%. A clearer separation of benign and malignant lesions is seen with E values rather than with SUV. Hepatic Glucose Phosphorylation: Functional CT and FDG-PET were utilised to obtain measurements of perfusion and glucose uptake respectively within the livers of a series of 35 patients with colorectal cancer. Hepatic perfusion and the net influx constant were incorporated into FDG kinetic analysis to determine hepatic glucose phosphorylation fraction. SUV and Ki were significantly lower in the 12 patients with advanced disease (p=0.015 and p=0.013 respectively) whereas portal and total hepatic perfusion were increased (p=0.013 and p=0.008 respectively). Combining the PET and CT data yielded phosphorylation fractions of 1.14% and 0.74% for early and advanced disease respectively (p=0.002). By combining functional CT measurements of blood flow with PET measurements of FDG uptake, it is possible to calculate the extraction fraction of FDG and Hepatic glucose phosphorylation. The use of the extraction fraction has improved the distinction between malignant and

  2. Combining functional CT and FDG PET allows the calculation of FDG extraction fraction and hepatic glucose phosphorylation

    International Nuclear Information System (INIS)

    Griffiths, M.R.; Miles, K.A.; Keith, C.J.

    2002-01-01

    Perfusion data from Functional CT and FDG-PET data may be combined to provide additional information about the uptake of FDG. We have developed methods to calculate FDG extraction fraction in tissues and to quantify hepatic glucose phosphorylation in the liver. Extraction fraction: Functional CT and FDG-PET studies were used to obtain measurements of perfusion and glucose uptake respectively within ten pulmonary nodules. The net influx constant (Ki) was determined from SUV measurements for each lung mass Extraction fraction (E) for each mass lesion was determined from: E=Ki/(Px[1-Hct]). A pixel by pixel calculation allowed generation of extraction fraction maps. The extraction fraction measurements ranged (median) from 0.6% to 4.81% (2.7%). The values for a benign nodule and an organising pneumonia were 0.6% and 0.71% respectively. Extraction fraction measurements for the malignant nodules ranged from 2.01% to 4.81%. A clearer separation of benign and malignant lesions is seen with E values rather than with SUV. Hepatic Glucose Phosphorylation: Functional CT and FDG-PET were utilised to obtain measurements of perfusion and glucose uptake respectively within the livers of a series of 35 patients with colorectal cancer. Hepatic perfusion and the net influx constant were incorporated into FDG kinetic analysis to determine hepatic glucose phosphorylation fraction. SUV and Ki were significantly lower in the 12 patients with advanced disease (p=0.015 and p=0.013 respectively) whereas portal and total hepatic perfusion were increased (p=0.013 and p=0.008 respectively). Combining the PET and CT data yielded phosphorylation fractions of 1.14% and 0.74% for early and advanced disease respectively (p=0.002). By combining functional CT measurements of blood flow with PET measurements of FDG uptake, it is possible to calculate the extraction fraction of FDG and Hepatic glucose phosphorylation. The use of the extraction fraction has improved the distinction between malignant and

  3. Hypoglycemic depression of hepatic phagocytosis in vivo and in the in situ perfused rat liver.

    Science.gov (United States)

    Kober, P M; Filkins, J P

    1981-01-01

    Depression of the phagocytic function of the reticuloendothelial system (RES) during endotoxic hypoglycemia has been implicated in the pathogenesis of endotoxin shock. The present study evaluated the in vivo effects of hypoglycemia on RES function and assessed the effects of an vivo bout of hypoglycemia on phagocytosis in the in situ perfused rat liver. Hypoglycemia was produced in male Holtzman rats using either 1 U of regular insulin (RI) (ILETIN, Lilly) or 0.75 U of long-acting insulin (LAI) (85% LENTE/15% ULTRALENTE, Lilly). RES function was quantitated by intravascular clearance of 8 mg/100 gm body weight colloidal carbon (CC). Two hr after RI and 2.5 hr after LAI, the intravascular halftimes of CC clearance were 19 +/- 2 min (N = 22) and 18 +/- 1 min (N = 19), respectively, as compared to control, 11.3 +/- 0.4 min (N = 53, P less than 0.001). The corresponding plasma glucose (PG) levels were 95 +/- 2 mg/dl in control, 14.4 +/- 0.9 for the RI group, and 17 +/- 1 for LAI. Two hr after RI, livers were perfused for 10 min in situ with 50 mg/liter CC in saline 5% rat serum. PG for control liver donors were 90 +/- 3 mg/dl, while those for hypoglycemic liver donors were 15 +/- 2. CC uptake was decreased from 22 micrograms/min/gm liver in the control (+ serum, n = 19) to 11 +/- 2 in hypoglycemia livers (N = 6); no effect of serum on hypoglycemic depression of the RES was seen. There were no differences in flow rates in the 2 groups. These results indicate that hypoglycemia directly impairs RES function and that the in vivo depression of intravascular clearance is not related to either the presence or absence of serum factors or total hepatic blood flow. Thus, the characteristic hypoglycemia of endotoxin shock may contribute to RES depression and the lethal shock syndrome.

  4. Quantitative assessment of hepatic and splenic blood flow detected by Tc-99m-Sn colloid liver scintigraphy

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Nishiyama, Shoji; Sugimura, Kazuro

    1983-01-01

    Quantitative assessment of hepatic and splenic blood flow detected by injecting Tc-99m-Sn colloid as a bolus was performed on 75 patients who were suspected of having liver disease. Using a computer, the hepatic and splenic time-activity curves were analyzed. Hepatic index was calculated as the ratio of arterial to portal blood flow. The peak time of the right kidney was corresponded to the junction of the arterial and portal phases of the hepatic curve. Splenic index was calculated as the ratio of splenic arterial to liver arterial blood flow. Hepatic and splenic indices had elevated in cases of liver cirrhosis and hepatoma than those of normal controls. There was no significant difference in the hepatic and splenic indices among chronic hepatitis, liver metastasis and normal subject. These noninvasive tests for the hepatic and splenic blood flow may be useful in writing a report of liver scintigram because of the added information of the liver. (author)

  5. Radionuclide and dopplergraphic assessment of portal hepatic blood flow in opisthorchiasis

    International Nuclear Information System (INIS)

    Borodulin, V.G.; Ermolitskij, N.M.; Zavadovskaya, V.D.; Prosekina, N.M.; Borodulin, Yu.V.

    1996-01-01

    Dynamic studies of the portal blood flow were carried out in 88 patients using colloid radionuclide gold-198 and Tc-99m-phytate and in 84 patients by dopplerography. Radionuclide studies showed that both radiopharmaceutical adequately reflected the portal blood flow in the liver. Portal blood flow values obtained by the duplex echographic method were 0.7 times lower than these estimated by radionuclide indirect angiography. The authors come to a conclusions that the share of the liver in colloid capture should be taken into consideration for the correct estimation of the level of portal hepatic hemodynamics. Portal hepatic blood flow was found markedly reduced in patients with chronic opisthorchiasis in comparison with normal controls, this difference being more expressed in male patients [ru

  6. Elevation of the correlation between cerebral blood volume and permeability surface from CT perfusion images with glioma grade

    International Nuclear Information System (INIS)

    Ding Bei; Ling Huawei; Zhang Huan; Song Qi; Dong Haipeng; Chen Kemin

    2007-01-01

    Objective: To evaluate the correlation between cerebral blood volume and permeability surface by using multislice CT perfusion imaging with glioma grade. Methods: Ninteen patients with gliomas underwent conventional MR and multislice CT perfusion imaging preoperatively. These patients were divided into low grade and high grade groups which were correspond to WHO II grade gliomas and WHO III or IV grade gliomas respectively. CT data were transferred to on-line working station and processed to obtain time-signal curves, color perfusion maps and calculated perfusion parameters, including cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTF) and permeability surfaces (PS) in tumoral parenchyma. Kruskal-Wallis test and correlation of CBV and PS was assessed by using SPSS 11.0 software. Results: The median of CBV and PS in low-grade and high-grade glioma were 2.7, 6.5 ml/100 g; 0.389, 12.810 ml·100 g -1 ·min -1 respectively, corresponding t value were 12.907 13.500 with P<0.05. Pearson correlations between CBV and PS were as follows: in low-grade group, r=-0.058, in high-grade group, r=0.648. Conclusion: Both CBV and PS have obvious correlation with glioma grade. The correlation between CBV and PS in low-grade glioma was weaker, probably because of the focal high vascularity in oligodendroglioma. (authors)

  7. The Use of an Acellular Oxygen Carrier in a Human Liver Model of Normothermic Machine Perfusion.

    Science.gov (United States)

    Laing, Richard W; Bhogal, Ricky H; Wallace, Lorraine; Boteon, Yuri; Neil, Desley A H; Smith, Amanda; Stephenson, Barney T F; Schlegel, Andrea; Hübscher, Stefan G; Mirza, Darius F; Afford, Simon C; Mergental, Hynek

    2017-11-01

    Normothermic machine perfusion of the liver (NMP-L) is a novel technique that preserves liver grafts under near-physiological conditions while maintaining their normal metabolic activity. This process requires an adequate oxygen supply, typically delivered by packed red blood cells (RBC). We present the first experience using an acellular hemoglobin-based oxygen carrier (HBOC) Hemopure in a human model of NMP-L. Five discarded high-risk human livers were perfused with HBOC-based perfusion fluid and matched to 5 RBC-perfused livers. Perfusion parameters, oxygen extraction, metabolic activity, and histological features were compared during 6 hours of NMP-L. The cytotoxicity of Hemopure was also tested on human hepatic primary cell line cultures using an in vitro model of ischemia reperfusion injury. The vascular flow parameters and the perfusate lactate clearance were similar in both groups. The HBOC-perfused livers extracted more oxygen than those perfused with RBCs (O2 extraction ratio 13.75 vs 9.43 % ×10 per gram of tissue, P = 0.001). In vitro exposure to Hemopure did not alter intracellular levels of reactive oxygen species, and there was no increase in apoptosis or necrosis observed in any of the tested cell lines. Histological findings were comparable between groups. There was no evidence of histological damage caused by Hemopure. Hemopure can be used as an alternative oxygen carrier to packed red cells in NMP-L perfusion fluid.

  8. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  9. The determination of hepatic blood flow in the rat using Xenon-133

    International Nuclear Information System (INIS)

    Smith, A.; Clarke, M.B.

    1976-01-01

    The measurement of hepatic blood flow in rats undergoing surgical trauma using different anaesthetic techniques has been carried out using the 133 Xe clearance method. Injection into the hepatic artery is followed by monitoring of the liver radioactivity. The complex clearance curves have been analysed using a computer. Details of the surgical technique and the care of the animal while undergoing examination are given. The physiological basis for the clearance curves observed is analysed and a survey of the various parameters which may produce changes in clearance rates is made. Comparison with other investigations show that rat liver blood flows obtained using the 133 Xe clearance method are consistent with others using non-radioactive techniques; because of its simplicity and ease of repetition, the Xenon method is recommended as a way of evaluating drug effects on hepatic blood flow in experimental animals. (author)

  10. Macro- and microelements in the rat liver, kidneys, and brain tissues; sex differences and effect of blood removal by perfusion in vivo.

    Science.gov (United States)

    Orct, Tatjana; Jurasović, Jasna; Micek, Vedran; Karaica, Dean; Sabolić, Ivan

    2017-03-01

    Concentrations of macro- and microelements in animal organs indicate the animal health status and represent reference data for animal experiments. Their levels in blood and tissues could be different between sexes, and could be different with and without blood in tissues. To test these hypotheses, in adult female and male rats the concentrations of various elements were measured in whole blood, blood plasma, and tissues from blood-containing (nonperfused) and blood-free liver, kidneys, and brain (perfused in vivo with an elements-free buffer). In these samples, 6 macroelements (Na, Mg, P, S, K, Ca) and 14 microelements (Fe, Mn, Co, Cu, Zn, Se, I, As, Cd, Hg, Pb, Li, B, Sr) were determined by inductively coupled plasma mass spectrometry following nitric acid digestion. In blood and plasma, female- or male-dominant sex differences were observed for 6 and 5 elements, respectively. In nonperfused organs, sex differences were observed for 3 (liver, brain) or 9 (kidneys) elements, whereas in perfused organs, similar differences were detected for 9 elements in the liver, 5 in the kidneys, and none in the brain. In females, perfused organs had significantly lower concentrations of 4, 5, and 2, and higher concentrations of 10, 4, and 7 elements, respectively, in the liver, kidneys, and brain. In males, perfusion caused lower concentrations of 4, 7, and 2, and higher concentrations of 1, 1, and 7 elements, respectively, in the liver, kidneys, and brain. Therefore, the residual blood in organs can significantly influence tissue concentrations of various elements and their sex-dependency. Copyright © 2017 Elsevier GmbH. All rights reserved.

  11. Effect of in situ hypothermic perfusion on intrahepatic pO(2) and reactive oxygen species formation after partial hepatectomy under total hepatic vascular exclusion in pigs

    NARCIS (Netherlands)

    Heijnen, Bob H. M.; Straatsburg, Irene H.; Kager, Liesbeth M.; van der Kleij, Ad J.; Gouma, Dirk J.; van Gulik, Thomas M.

    2003-01-01

    Aim: This study examined attenuation of ischemia and reperfusion (I/R) induced liver injury during liver resections by hypothermic perfusion of the liver under total hepatic vascular exclusion (THVE). Method: Reactive oxygen species (ROS) formation, microcirculatory integrity and endothelial cell

  12. Prevalence of human immunodeficiency virus, syphilis, hepatitis B and C in blood donations in Namibia.

    Science.gov (United States)

    Mavenyengwa, Rooyen T; Mukesi, Munyaradzi; Chipare, Israel; Shoombe, Esra

    2014-05-05

    Transfusion Transmissible Infections (TTIs) such as Human Immunodeficiency Virus (HIV), syphilis, hepatitis B virus (HBV) and hepatitis C virus (HCV) are infections which are common in some communities in Southern Africa. It is important to screen blood donations for these infections. This is a retrospective study which involved reviewing of previous blood donation records for the year 2012 in Namibia. The records were analyzed to determine the prevalence of HIV, syphilis, Hepatitis B and C among blood donations with regard to gender, age and geographical region of the donors. The findings indicated a significantly low prevalence of HIV, syphilis, HBsAg and anti-Hepatitis C among the blood donations. A low infection rate of 1.3% by any of the four tested TTIs was found among the blood donations given by the donor population in Namibia in 2012. The blood donations given by the donor population in Namibia has a low infection rate with the HIV, syphilis, HBsAg and anti-HCV. A strict screening regime must continue to be used as the infections are still present albeit in small numbers.

  13. Whole-body imaging of whole-organ, subresolution, basic functional unit (BFU) perfusion characteristics

    Science.gov (United States)

    Dong, Yue; Ritman, Erik L.

    2008-08-01

    A BFU is an organ's smallest assembly of diverse cells that functions like the organ, such as the liver's hepatic lobules. There are approximately 107 BFUs in a human organ. These 100-200 μm structures are perfused by capillaries fed by a terminal arteriole (15μm diameter). BFU sizes, function and number per organ vary with disease, either by loss of BFUs and/or their decrease in function. The BFU is the upper limit of a spherical assembly of cells, immersed in a suitably nutrient medium, which can survive without its own blood supply. However, each BFU has its own blood supply to support the extra energy and/or solutes needed for providing its physiological function (e.g., contraction or secretion). A BFU function is best evaluated by its micro-perfusion, which can be readily evaluated with whole-body CT. Resolution of individual BFUs within in-situ organs, using clinical imaging devices, would require high radiation doses and/or the intolerably long scan-durations needed for suitable signal-to-noise image-data. However, it is possible to obtain a statistical description of the BFU number, size and function from wholebody CT by way of a model. In this study we demonstrate this capability by using the distribution of myocardial terminal arteriolar perfusion territories by way of a nested, multiple, regions-of-interest analysis of the heart wall imaged during transient opacification of its blood supply.

  14. Cerebral misery perfusion diagnosed using hypercapnic blood-oxygenation-level-dependent contrast functional magnetic resonance imaging: a case report

    Directory of Open Access Journals (Sweden)

    D'Souza Olympio

    2010-02-01

    Full Text Available Abstract Introduction Cerebral misery perfusion represents a failure of cerebral autoregulation. It is an important differential diagnosis in post-stroke patients presenting with collapses in the presence of haemodynamically significant cerebrovascular stenosis. This is particularly the case when cortical or internal watershed infarcts are present. When this condition occurs, further investigation should be done immediately. Case presentation A 50-year-old Caucasian man presented with a stroke secondary to complete occlusion of his left internal carotid artery. He went on to suffer recurrent seizures. Neuroimaging demonstrated numerous new watershed-territory cerebral infarcts. No source of arterial thromboembolism was demonstrable. Hypercapnic blood-oxygenation-level-dependent-contrast functional magnetic resonance imaging was used to measure his cerebrovascular reserve capacity. The findings were suggestive of cerebral misery perfusion. Conclusions Blood-oxygenation-level-dependent-contrast functional magnetic resonance imaging allows the inference of cerebral misery perfusion. This procedure is cheaper and more readily available than positron emission tomography imaging, which is the current gold standard diagnostic test. The most evaluated treatment for cerebral misery perfusion is extracranial-intracranial bypass. Although previous trials of this have been unfavourable, the results of new studies involving extracranial-intracranial bypass in high-risk patients identified during cerebral perfusion imaging are awaited. Cerebral misery perfusion is an important and under-recognized condition in which emerging imaging and treatment modalities present the possibility of practical and evidence-based management in the near future. Physicians should thus be aware of this disorder and of recent developments in diagnostic tests that allow its detection.

  15. Radionuclide study on hepatic blood flow in Schistosomiasis Japonica

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Junichi; Uchiyama, Guio; Hayakawa, Kazushige; Hayashi, Sanshin; Araki, Tsutomu; Arai, Takao; Iuchi, Masahiko

    1986-11-01

    Schistosomiasis Japonica is a regional disease found in elderly people who were living in once-endemic areas in Japan. Yamanashi was one of these areas until 1970, since when no newly infected patients were reported. The disease is characteristic of developing irreversible interstitial fibrosis of the liver, where parasites migrate and lay eggs. Portal hypertension, esophageal varices and hepatocellular carcinomas are the common features of the results. In order to estimate patient's hepatic blood flow, radionuclide angiography of the liver with the use of 10 - 15 millicuries of Tc-99m phytate were performed prior to the conventional multiview imaging. Twenty-two patients with schistosomiasis and twelve adults without evidence of liver disease were studied. A time-activity curve of the right lobe of the liver was generated by a computer, and the ratio of arterial blood flow to portal blood flow was calculated. As a result, a good correlation was found between the arterial to portal blood flow ratio and the grade of hepatic fibrosis verified by laparoscopic biopsy. The development of esophageal varices were likely to correlate well with the blood flow ratio rather than scores on the conventional static liver and spleen scintigram. The study was useful for evaluating patient's clinical stages and prognosis.

  16. Radionuclide study on hepatic blood flow in Schistosomiasis Japonica

    International Nuclear Information System (INIS)

    Okada, Junichi; Uchiyama, Guio; Hayakawa, Kazushige; Hayashi, Sanshin; Araki, Tsutomu; Arai, Takao; Iuchi, Masahiko.

    1986-01-01

    Schistosomiasis Japonica is a regional disease found in elderly people who were living in once-endemic areas in Japan. Yamanashi was one of these areas until 1970, since when no newly infected patients were reported. The disease is characteristic of developing irreversible interstitial fibrosis of the liver, where parasites migrate and lay eggs. Portal hypertension, esophageal varices and hepatocellular carcinomas are the common features of the results. In order to estimate patient's hepatic blood flow, radionuclide angiography of the liver with the use of 10 - 15 millicuries of Tc-99m phytate were performed prior to the conventional multiview imaging. Twenty-two patients with schistosomiasis and twelve adults without evidence of liver disease were studied. A time-activity curve of the right lobe of the liver was generated by a computer, and the ratio of arterial blood flow to portal blood flow was calculated. As a result, a good correlation was found between the arterial to portal blood flow ratio and the grade of hepatic fibrosis verified by laparoscopic biopsy. The development of esophageal varices were likely to correlate well with the blood flow ratio rather than scores on the conventional static liver and spleen scintigram. The study was useful for evaluating patient's clinical stages and prognosis. (author)

  17. Liver perfusion CT during hepatic arteriography for the hepatocellular carcinoma: Dose reduction and quantitative evaluation for normal- and ultralow-dose protocol

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Shingo [Department of Radiology, Dokkyo Medical University Koshigaya Hospital, 2-1-50, Minami-Koshigaya, Koshigaya-shi, Saitama 343-8555 (Japan); Katada, Yoshiaki, E-mail: yoshiaki@dokkyomed.ac.jp [Department of Radiology, Dokkyo Medical University Koshigaya Hospital, 2-1-50, Minami-Koshigaya, Koshigaya-shi, Saitama 343-8555 (Japan); Gohkyu, Masaki; Nakajima, Masahiro; Kawabata, Hideyuki; Nozaki, Miwako [Department of Radiology, Dokkyo Medical University Koshigaya Hospital, 2-1-50, Minami-Koshigaya, Koshigaya-shi, Saitama 343-8555 (Japan)

    2012-12-15

    Objectives: The purpose of this study was to investigate whether substantial reduction of the computed tomography (CT) dose is possible in liver CT perfusion imaging by comparing the results of ultralow-dose CT perfusion imaging with those of conventional CT perfusion imaging the same patients and under the same conditions. Materials and methods: The study was composed following two parts: computer simulation and patients study. In computer simulation, noise was added to the images so that the standard deviation (SD) of the CT values in the liver parenchyma became various values using ImageJ. Time density curves (TDCs) were created from the simulated data, and the influence of difference in the SDs on the shapes of the TDCs was investigated. In the patient study, CT perfusion during intra-arterial injection was performed in 30 consecutive patients undergoing transcatheter arterial chemoembolization. CT perfusion images were acquired twice, at 100 mA (CTDI{sub vol}, 300 mGy) for normal and at 20 mA (CTDI{sub vol}, 60 mGy) for the ultralow radiation doses, under the same conditions. Results: No change was observed in the shape of the TDCs and peak values in the analysis of simulation images. A very good correlation was observed between the normal- and ultralow-dose CT images for all analyzed values (R{sup 2} = 0.9885 for blood flow, 0.9269 for blood volume, and 0.8424 for mean transit time). Conclusions: Our results demonstrated that there was no significant difference in the analysis results of perfusion CT between ultralow-dose CT performed using 20% of the conventional dose and normal-dose CT perfusion.

  18. Pulmonary artery perfusion versus no pulmonary perfusion during cardiopulmonary bypass in patients with COPD

    DEFF Research Database (Denmark)

    Buggeskov, Katrine B; Sundskard, Martin M; Jonassen, Thomas

    2016-01-01

    INTRODUCTION: Absence of pulmonary perfusion during cardiopulmonary bypass (CPB) may be associated with reduced postoperative oxygenation. Effects of active pulmonary artery perfusion were explored in patients with chronic obstructive pulmonary disease (COPD) undergoing cardiac surgery. METHODS: 90...... perfusion with normothermic oxygenated blood during cardiopulmonary bypass appears to improve postoperative oxygenation in patients with COPD undergoing cardiac surgery. Pulmonary artery perfusion with hypothermic HTK solution does not seem to improve postoperative oxygenation. TRIAL REGISTRATION NUMBER...

  19. A deuterium and carbon nuclear magnetic resonance spectroscopic investigation of blood flow and carbohydrate metabolism

    International Nuclear Information System (INIS)

    Bosch, C.S.E.

    1988-01-01

    The purpose of this study is the development and application of nuclear magnetic resonance (NMR) spectroscopic techniques for this study of whole tissue metabolism, tissue perfusion and blood flow. The feasibility of spin imaging deuterium-enriched tissue water is demonstrated in cat brain in vivo and in situ. The potential application of D 2 O administration to deuterium-flow-imaging is considered. NMR investigations of hepatic carbohydrate metabolism were performed in rat liver in vivo and in situ. A coaxial, double-surface-coil, double-resonance probe was developed for carbon detection while decoupling neighboring proton scalar interactions ( 13 C-[ 1 H]) in hepatic tissue within the living animal. Hormonal and substrate regulation of hepatic glucose and glycogen metabolism was investigated by monitoring the metabolic fate of an administered c-dose of [1- 13 C]glucose. Label flux was directed primarily into newly-synthesized 13 C-labeled glycogen. A multiple resonance ( 1 H, 13 C, 31 P) liver perfusion probe was designed for complimentary carbohydrate metabolic studies in rat liver in vitro. A description of the 13 C-[ 1 H]/ 31 P NMR perfusion probe is given. The surgical technique used for liver excision and peripheral life-support apparatus required to maintain hepatic function are also detailed

  20. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  1. MRI-based assessment of liver perfusion and hepatocyte injury in the murine model of acute hepatitis.

    Science.gov (United States)

    Byk, Katarzyna; Jasinski, Krzysztof; Bartel, Zaneta; Jasztal, Agnieszka; Sitek, Barbara; Tomanek, Boguslaw; Chlopicki, Stefan; Skorka, Tomasz

    2016-12-01

    To assess alterations in perfusion and liver function in the concanavalin A (ConA)-induced mouse model of acute liver failure (ALF) using two magnetic resonance imaging (MRI)-based methods: dynamic contrast-enhanced MRI (DCE-MRI) with Gd-EOB-DTPA contrast agent and arterial spin labelling (ASL). BALB/c mice were studied using a 9.4 T MRI system. The IntraGateFLASH TM and FAIR-EPI pulse sequences were used for optimum mouse abdomen imaging. The average perfusion values for the liver of the control and ConA group were equal to 245 ± 20 and 200 ± 32 ml/min/100 g (p = 0.008, respectively). DCE-MRI showed that the time to the peak of the image enhancement was 6.14 ± 1.07 min and 9.72 ± 1.69 min in the control and ConA group (p < 0.001, respectively), while the rate of the contrast wash-out in the control and ConA group was 0.037 ± 0.008 and 0.021 ± 0.008 min -1 (p = 0.004, respectively). These results were consistent with hepatocyte injury in the ConA-treated mice as confirmed by histopathological staining. Both the ASL and DCE-MRI techniques represent a reliable methodology to assess alterations in liver perfusion and hepatocyte integrity in murine hepatitis.

  2. Hepatitis B Virus Blood Screening: Need for Reappraisal of Blood Safety Measures?

    Directory of Open Access Journals (Sweden)

    Daniel Candotti

    2018-02-01

    Full Text Available Over the past decades, the risk of HBV transfusion–transmission has been steadily reduced through the recruitment of volunteer donors, the selection of donors based on risk-behavior evaluation, the development of increasingly more sensitive hepatitis B antigen (HBsAg assays, the use of hepatitis B core antibody (anti-HBc screening in some low-endemic countries, and the recent implementation of HBV nucleic acid testing (NAT. Despite this accumulation of blood safety measures, the desirable zero risk goal has yet to be achieved. The residual risk of HBV transfusion–transmission appears associated with the preseroconversion window period and occult HBV infection characterized by the absence of detectable HBsAg and extremely low levels of HBV DNA. Infected donations tested false-negative with serology and/or NAT still persist and derived blood components were shown to transmit the virus, although rarely. Questions regarding the apparent redundancy of some safety measures prompted debates on how to reduce the cost of HBV blood screening. In particular, accumulating data strongly suggests that HBsAg testing may add little, if any HBV risk reduction value when HBV NAT and anti-HBc screening also apply. Absence or minimal acceptable infectious risk needs to be assessed before considering discontinuing HBsAg. Nevertheless, HBsAg remains essential in high-endemic settings where anti-HBc testing cannot be implemented without compromising blood availability. HBV screening strategy should be decided according to local epidemiology, estimate of the infectious risk, and resources.

  3. Resting quantitative cerebral blood flow in schizophrenia measured by pulsed arterial spin labeling perfusion MRI

    OpenAIRE

    Pinkham, Amy; Loughead, James; Ruparel, Kosha; Wu, Wen-Chau; Overton, Eve; Gur, Raquel; Gur, Ruben

    2011-01-01

    Arterial spin labeling imaging (ASL) perfusion MRI is a relatively novel technique that can allow for quantitative measurement of cerebral blood flow (CBF) by using magnetically labeled arterial blood water as an endogenous tracer. Available data on resting CBF in schizophrenia primarily comes from invasive and expensive nuclear medicine techniques that are often limited to small samples and yield mixed results. The noninvasive nature of ASL offers promise for larger-scale studies. The utilit...

  4. Prediction of occult hepatitis B virus infection in liver transplant donors through hepatitis B virus blood markers.

    Science.gov (United States)

    Tandoi, Francesco; Caviglia, Gian Paolo; Pittaluga, Fabrizia; Abate, Maria Lorena; Smedile, Antonina; Romagnoli, Renato; Salizzoni, Mauro

    2014-11-01

    Occult hepatitis B virus infection is defined as detectable HBV-DNA in liver of HBsAg-negative individuals, with or without detectable serum HBV-DNA. In deceased liver donors, results of tissue analysis cannot be obtained prior to allocation for liver transplantation. we investigated prevalence and predictability of occult hepatitis B using blood markers of viral exposure/infection in deceased liver donors. In 50 consecutive HBsAg-negative/anti-HBc-positive and 20 age-matched HBsAg-negative/anti-HBc-negative donors, a nested-PCR assay was employed in liver biopsies for diagnosis of occult hepatitis B according to Taormina criteria. All donors were characterized for plasma HBV-DNA and serum anti-HBs/anti-HBe. In liver tissue, occult hepatitis B was present in 30/50 anti-HBc-positive (60%) and in 0/20 anti-HBc-negative donors (pdonors with detectable HBV-DNA in plasma (n=5) or anti-HBs>1,000 mIU/mL (n=5) eventually showed occult infection, i.e, 10/30 occult hepatitis B-positive donors which could have been identified prior to transplantation. In the remaining 40 anti-HBc-positive donors, probability of occult infection was 62% for anti-HBe-positive and/or anti-HBs ≥ 58 mIU/mL; 29% for anti-HBe-negative and anti-HBsdonors, combining anti-HBc with other blood markers of hepatitis B exposure/infection allows to predict occult hepatitis B with certainty and speed in one third of cases. These findings might help refine the allocation of livers from anti-HBc-positive donors. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  5. Influence of autologous blood transfusion in liver transplantation in patients with hepatitis B on the function and hemorheology of red blood cells

    OpenAIRE

    Liu, Xiangfu; Fan, Ruifang; Lu, Ying; Kuang, Lihua; Yuan, Qing; Chen, Yuchan; Lin, Zhesheng; Lin, Dongjun

    2017-01-01

    The present study aimed to characterize the function and hemorheology of red blood cells (RBCs) recovered during liver transplantation surgery in patients with hepatitis B and decompensation. A total of 15 hepatitis B patients with decompensation who underwent liver transplantation surgery were included in the present study. Blood samples were recovered during the liver transplantation surgery using an Autologous Blood Recovery System. The morphology and structure of RBCs were characterized a...

  6. The Urgency to Mitigate the Spread of Hepatitis C in Pakistan Through Blood Transfusion Reform

    Science.gov (United States)

    Alaei, Kamiar; Sarwar, Mohammad; Alaei, Arash

    2018-01-01

    Blood transfusions are contributing to a higher rate of hepatitis C virus (HCV) in Pakistan. Half of all blood transfusions in Pakistan are not screened for hepatitis C, hepatitis B or HIV. Family members donate blood that is likely not tested due to social stigma attached to HCV. Paid donations are also quite common in the country, especially by people who inject drugs (PWID), which increases the population’s exposure to HCV. Most of the population utilizes the private sector for their health needs; this sector has lax regulation due to the lack of oversight by the government or any other regulatory body. In addition, groups who are at most need for blood transfusions, such as hemophiliacs and those with thalassemia, have a higher rate of hepatitis C. This fact reinforces the need for blood transfusion reform in Pakistan, which includes improving oversight, upgrading infrastructure and promoting health literacy through cultural norms, according to the World Health Organization (WHO) recommendations. The lessons learned in Pakistan can be adapted to countries facing similar issues. PMID:29524949

  7. Control of ketogenesis in the perfused rat liver by the sympathetic innervation

    NARCIS (Netherlands)

    Beuers, U.; BECKH, K.; JUNGERMANN, K.

    1986-01-01

    The regulation of ketogenesis by the hepatic nerves was investigated in the rat liver perfused in situ. Electrical stimulation of the hepatic nerves around the portal vein and the hepatic artery caused a reduction of basal ketogenesis owing to a decrease in acetoacetate release to 30% with

  8. [Prevalences of HIV, hepatitis B and hepatitis C in blood donors in the Republic of Djibouti].

    Science.gov (United States)

    Dray, X; Dray-Spira, R; Bronstein, J A; Mattera, D

    2005-01-01

    Screening for hepatitis B (HBV) surface antigen (Ag HBs) and for antibodies to hepatitis C (HCV) and human: immunodeficiency virus (HIV) was carried out in 9006 volunteer blood donors at the National Blood Bank in the Republic of Djibouti from 1998 to 2000. Results demonstrated the presence of Ag HBs in 934 patients (10.4%), antibodies to HCV in 21 patients (0.3%), and antibodies to HIV in 175 patients (1.9%). In comparison with neighboring countries the prevalence of HBV, HCV, and HIV infection in Djibouti was low. These findings should be used to guide preventive action against these viral infections in the Republic of Djibouti. Estimations of HIV infection (11.7%) based on modeling by the World Health Organization should be reviewed.

  9. Transmission of viral hepatitis by blood and blood derivatives: current risks, past heritage.

    Science.gov (United States)

    Prati, D

    2002-11-01

    For more than 40 years in the history of transfusion medicine, transmission of viral hepatitis from infected donors to recipients has been a frequent and serious adverse effect of the administration of blood components and plasma derivatives. This epidemic is now over, at least in developed and resource-rich countries. Hence, the attention of clinicians and investigators now focuses mainly on the measures to reduce the residual risk, on the possible emergence of novel or undiscovered agents causing post-transfusion hepatitis, and on the long-term outcome of patients who became infected more than ten years ago. The present article reviews these issues.

  10. Dual-energy perfusion-CT of pancreatic adenocarcinoma

    International Nuclear Information System (INIS)

    Klauß, M.; Stiller, W.; Pahn, G.; Fritz, F.; Kieser, M.; Werner, J.; Kauczor, H.U.; Grenacher, L.

    2013-01-01

    Purpose: To evaluate the feasibility of dual-energy CT (DECT)-perfusion of pancreatic carcinomas for assessing the differences in perfusion, permeability and blood volume of healthy pancreatic tissue and histopathologically confirmed solid pancreatic carcinoma. Materials and methods: 24 patients with histologically proven pancreatic carcinoma were examined prospectively with a 64-slice dual source CT using a dynamic sequence of 34 dual-energy (DE) acquisitions every 1.5 s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). 80 kV p , 140 kV p , and weighted average (linearly blended M0.3) 120 kV p -equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool (Body-PCT, Siemens Medical Solutions, Erlangen, Germany) for estimating perfusion, permeability, and blood volume values. Color-coded parameter maps were generated. Results: In all 24 patients dual-energy CT-perfusion was. All carcinomas could be identified in the color-coded perfusion maps. Calculated perfusion, permeability and blood volume values were significantly lower in pancreatic carcinomas compared to healthy pancreatic tissue. Weighted average 120 kV p -equivalent perfusion-, permeability- and blood volume-values determined from DE image data were 0.27 ± 0.04 min −1 vs. 0.91 ± 0.04 min −1 (p −1 vs. 0.67 ± 0.05 *0.5 min −1 (p = 0.06) and 0.49 ± 0.07 min −1 vs. 1.28 ± 0.11 min −1 (p p the standard deviations of the kV p 120 kV p -equivalent values were manifestly smaller. Conclusion: Dual-energy CT-perfusion of the pancreas is feasible. The use of DECT improves the accuracy of CT-perfusion of the pancreas by fully exploiting the advantages of enhanced iodine contrast at 80 kV p in combination with the noise reduction at 140 kV p . Therefore using dual-energy perfusion data could improve the delineation of pancreatic carcinomas

  11. Hepatitis C Virus Seroprevalence in Blood Donors at the University ...

    African Journals Online (AJOL)

    Background/Aim: Hepatitis C Virus (HCV) is a leading cause of chronic liver disease worldwide. In developing countries, blood transfusion is still a major route of its transmission. The aim of this study was to determine the seroprevalence of HCV infection among blood donors and to determine some of the risk factors for the ...

  12. Transfusion-Transmitted Hepatitis E: NAT Screening of Blood Donations and Infectious Dose.

    Science.gov (United States)

    Dreier, Jens; Knabbe, Cornelius; Vollmer, Tanja

    2018-01-01

    The risk and importance of transfusion-transmitted hepatitis E virus (TT-HEV) infections by contaminated blood products is currently a controversial discussed topic in transfusion medicine. The infectious dose, in particular, remains an unknown quantity. In the present study, we illuminate and review this aspect seen from the viewpoint of a blood donation service with more than 2 years of experience in routine HEV blood donor screening. We systematically review the actual status of presently known cases of TT-HEV infections and available routine NAT-screening assays. The review of the literature revealed a significant variation regarding the infectious dose causing hepatitis E. We also present the outcome of six cases confronted with HEV-contaminated blood products, identified by routine HEV RNA screening of minipools using the highly sensitive RealStar HEV RT-PCR Kit (95% LOD: 4.7 IU/mL). Finally, the distribution of viral RNA in different blood components [plasma, red blood cell concentrate (RBC), platelet concentrates (PC)] was quantified using the first WHO international standard for HEV RNA for NAT-based assays. None of the six patients receiving an HEV-contaminated blood product from five different donors (donor 1: RBC, donor 2-5: APC) developed an acute hepatitis E infection, most likely due to low viral load in donor plasma (donations should be adequate as a routine screening assay to identify high viremic donors and will cover at least a large part of viremic phases.

  13. Evaluation of MSCTA for parasitic blood supply in hepatic carcinoma

    International Nuclear Information System (INIS)

    Yang Weihong; Liu Pengcheng; Liang Shanhu; Yuan Zhidong; Yu Hongjian; Deng Qianhua

    2008-01-01

    Objective: To evaluate the multi-slice spiral computer tomography for hepatocarcinoma parasitic blood supply, and analyze the mechanism of the parasitic angiogenesis. Methods: Forty cases confirmed by DSA and confirmed with the existence of parasitic blood supply through manifestations of MSCTA were retrospectively analized. Comparing the coincidence of different reconstruction modalities of MSCTA and DSA in displaying the parasitic blood supply and then to assess the characteristics of MSCTA of the cases with existing parasitic blood supply. Results: DSA displayed parasitic blood supply in 50 arterial rami and MSCTA displayed only 40 rami, with positive rate of 80%. The best display could be reached by the reconstruction of combining MIP and VRT. This kind of reconstruction revealed not only the parasitic blood supply but also the peripheral sites of the primary focci with average length of diameter of 6.9 cm. Conclusions: MSCTA possesses nearly the same capability with DSA in demonstrating the parasitic blood supply to primary hepatic carcinoma, therefore it could be utilized in evaluation of intervention therapy and surgical, operation and transplantation. The primary hepatic carcinoma with this kind of parasitic blood supply is always located at the bare were of liver and ligmentarn suspensoram together with direct invasion of nearby organs with adhesions may contribute the main factor of parasitic blood supply, furthermore the repetition of TACE inducing the decrease of collateral circulation may also be the another major factor. (authors)

  14. Evaluation of MSCTA for parasitic blood supply in hepatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Weihong, Yang; Pengcheng, Liu; Shanhu, Liang; Zhidong, Yuan; Hongjian, Yu; Qianhua, Deng [Department of Radiology, Shenzhen Hospital of Beijing College, Guangdong, Shenzhen (China)

    2008-09-15

    Objective: To evaluate the multi-slice spiral computer tomography for hepatocarcinoma parasitic blood supply, and analyze the mechanism of the parasitic angiogenesis. Methods: Forty cases confirmed by DSA and confirmed with the existence of parasitic blood supply through manifestations of MSCTA were retrospectively analized. Comparing the coincidence of different reconstruction modalities of MSCTA and DSA in displaying the parasitic blood supply and then to assess the characteristics of MSCTA of the cases with existing parasitic blood supply. Results: DSA displayed parasitic blood supply in 50 arterial rami and MSCTA displayed only 40 rami, with positive rate of 80%. The best display could be reached by the reconstruction of combining MIP and VRT. This kind of reconstruction revealed not only the parasitic blood supply but also the peripheral sites of the primary focci with average length of diameter of 6.9 cm. Conclusions: MSCTA possesses nearly the same capability with DSA in demonstrating the parasitic blood supply to primary hepatic carcinoma, therefore it could be utilized in evaluation of intervention therapy and surgical, operation and transplantation. The primary hepatic carcinoma with this kind of parasitic blood supply is always located at the bare were of liver and ligmentarn suspensoram together with direct invasion of nearby organs with adhesions may contribute the main factor of parasitic blood supply, furthermore the repetition of TACE inducing the decrease of collateral circulation may also be the another major factor. (authors)

  15. Seroprevalence of hiv and hepatitis viruses in directed blood donors ...

    African Journals Online (AJOL)

    Aims: To determine the seroprevalence of HIV and Hepatitis B viruses in directed blood donors in Nguru and also to see if there is co-infection of these viruses in this category of donor population. Method: This is a prospective study carried out at the blood bank of the Federal Medical Centre Nguru, Yobe State between ...

  16. Radioembolization of hepatic tumors. Flow redistribution after the occlusion of intrahepatic arteries

    International Nuclear Information System (INIS)

    Lauenstein, T.C.; Heusner, T.A.; Antoch, G.; Hamami, M.; Bockisch, A.; Ertle, J.; Schlaak, J.F.; Gerken, G.

    2011-01-01

    Radioembolization using 90yttrium is an emerging therapy option for unresectable liver malignancies. In order to reduce the number of yttrium injections, endovascular occlusion of a segmental hepatic artery has been proposed. The aim of this study was to assess whether sufficient vascular redistribution of the occluded liver segments through intrahepatic collaterals can be observed. 27 patients with hepatocellular carcinoma (n = 16) or hepatic metastases (n = 11) were studied. Hepatic angiography was performed on average 16 days prior to radioembolization. The segment II/III artery (n = 9) or the segment IV artery (n = 18) was occluded using coils. Technectium-99m-labeled macroaggregated albumin (99mTc-MAA) was injected into the right and the remaining part of the left hepatic artery in order to identify any hepatic volume not included in the perfused area. Patients underwent a SPECT/CT on average 1 h after the 99mTc-MAA injection. Two radiologists evaluated the SPECT/CT scans regarding the presence of non-perfused hepatic segments. Furthermore, hepatic perfusion was assessed by digital subtraction angiography (DSA) on the day of radioembolization. In 16 / 27 patients (59 %) a perfusion of the occluded liver segment was visible on the SPECT/CT scan. In 8 / 11 patients without flow redistribution at the time of the SPECT/CT, perfusion of the occluded segment through hepatic collaterals was observed during angiography prior to radioembolization. Hence, flow redistribution was eventually found in 24 / 27 patients (89 %). Flow redistribution after the occlusion of intrahepatic arteries prior to radioembolization can be successfully induced in the majority of patients with anatomical variants of the hepatic arteries. (orig.)

  17. Rat liver contains a limited number of binding sites for hepatic lipase

    NARCIS (Netherlands)

    G.C. Schoonderwoerd (Kees); A.J.M. Verhoeven (Adrie); H. Jansen (Hans)

    1994-01-01

    textabstractThe binding of hepatic lipase to rat liver was studied in an ex vivo perfusion model. The livers were perfused with media containing partially purified rat hepatic lipase or bovine milk lipoprotein lipase. The activity of the enzymes was determined in the

  18. Brain perfusion spect imaging with sup 99m Tc-HM-PAO in Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Wenzhong, Song; Xiangtong, Lin [Shanghai Medical Univ. (China). Huashan Hospital

    1991-02-01

    Forty patients with Parkinson's disease were studied using {sup 99m}Tc-HM-PAO brain perfusion SPECT. 62.5% (25 cases) showed abnormal blood perfusion. Among them 55% showed local decreased blood perfusion of cerebral cortex, 22% showed asymmetric decreased blood perfusion in basal gaglia, 10% showed decreased uptake of tracer in cerebellum. The pathophysiologic basis of the abnormality of brain blood perfusion were briefly discussed.

  19. Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

    Science.gov (United States)

    Bretas, Elisa Almeida Sathler; Torres, Ulysses S; Torres, Lucas Rios; Bekhor, Daniel; Saito Filho, Celso Fernando; Racy, Douglas Jorge; Faggioni, Lorenzo; D'Ippolito, Giuseppe

    2017-10-01

    To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages. This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics. Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters. At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.

  20. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  1. Hepatic blood flow mapping by dynamic CT method in liver diseases

    International Nuclear Information System (INIS)

    Sugano, Shigeo; Mizuyosi, Hideo; Okajima, Tsugio; Ishii, Kouji; Abei, Tohru; Machida, Keiichi

    1986-01-01

    Two parameters of dynamic CT, peak time (PT) and first moment (M1), were compared among healthy control, chronic hepatitis (CH) and liver cirrhosis (LC). The means of PT and M1 in each 9 (3 x 3) pixels on a slice of hepatic CT were computed and converted to gray spots by gray scale, so that deep gray represented high values and light gray low values of these parameters. The distribution of these gray spots in each pixels was depicted on the slice as a blood flow mapping, and it was compared among the groups. In normal control, dynamic CT showed the shortest PT and deep gray spots were distributed diffusely in the slice. In CH, where PT was longer than control, lighter gray spots were diffusely seen. LC had the longest PT and its mapping showed mottles of light gray and black, the latter indicating the presence of spots with scanty blood flow, scattering throughout the slice. The mapping of M1 gave almost the same picture as PT for each group, revieling that the disappearring time of the media in CH and LC was impaired in the same manner as in PT. This method of hepatic blood flow mapping was thought to be useful to add evidences for the understanding of abnormal blood flow in liver diseases. (author)

  2. Haemoadsorption reduces the inflammatory response and improves blood flow during ex vivo renal perfusion in an experimental model.

    Science.gov (United States)

    Hosgood, Sarah A; Moore, Tom; Kleverlaan, Theresa; Adams, Tom; Nicholson, Michael L

    2017-10-25

    Ex-vivo normothermic perfusion strategies are a promising new instrument in organ transplantation. The perfusion conditions are designed to be protective however the artificial environment can induce a local inflammatory response. The aim of this study was to determine the effect of incorporating a Cytosorb adsorber into an isolated kidney perfusion system. Porcine kidneys were subjected to 22 h of cold ischaemia then reperfused for 6 h on an ex vivo reperfusion circuit. Pairs of kidneys were randomised to either control (n = 5) or reperfusion with a Cytosorb adsorber (n = 5) integrated into the circuit. Tissue, blood and urine samples were taken for the measurement of inflammation and renal function. Baseline levels of cytokines (IL-6, TNFα, IL-8, IL-10, IL-1β, IL-1α) were similar between groups. Levels of IL-6 and IL-8 in the perfusate significantly increased during reperfusion in the control group but not in the Cytosorb group (P = 0.023, 0.049). Levels of the other cytokines were numerically lower in the Cytosorb group; however, this did not reach statistical significance. The mean renal blood flow (RBF) was significantly higher in the Cytosorb group (162 ± 53 vs. 120 ± 35 mL/min/100 g; P = 0.022). Perfusate levels of prostaglandin E2 were significantly lower in the Cytosorb group (642 ± 762 vs. 3258 ± 980 pg/mL; P = 0.0001). Levels of prostacyclin were significantly lower in the Cytosorb group at 1, 3 and 6 h of reperfusion (P = 0.008, 0.003, 0.0002). Levels of thromboxane were also significantly lower in the Cytosorb group throughout reperfusion (P = 0.005). Haemoadsorption had no effect on creatinine clearance (P = 0.109). Haemoadsorption can reduce the inflammatory response and improve renal blood flow during perfusion. Nonetheless, in this model haemoadsorption had no influence on renal function and this may relate to the broad-spectrum action of the Cytosorb adsorber that also removes potentially important anti

  3. Dynamic Susceptibility Contrast Perfusion Magnetic Resonance Imaging Demonstrates Reduced Periventricular Cerebral Blood Flow in Dogs with Ventriculomegaly

    Directory of Open Access Journals (Sweden)

    Martin J. Schmidt

    2017-08-01

    Full Text Available The nature of ventriculomegaly in dogs is still a matter of debate. Signs of increased intraventricular pressure and atrophy of the cerebral white matter have been found in dogs with ventriculomegaly, which would imply increased intraventricular pressure and, therefore, a pathological condition, i.e., to some extent. Reduced periventricular blood flow was found in people with high elevated intraventricular pressure. The aim of this study was to compare periventricular brain perfusion in dogs with and without ventriculomegaly using perfusion weighted-magnetic-resonance-imaging to clarify as to whether ventriculomegaly might be associated with an increase in intraventricular pressure. Perfusion was measured in 32 Cavalier King Charles spaniels (CKCS with ventriculomegaly, 10 CKCSs were examined as a control group. Cerebral blood flow (CBF was measured using free-hand regions of interest (ROI in five brain regions: periventricular white matter, caudate nucleus, parietal cortex, hippocampus, and thalamus. CBF was significantly lower in the periventricular white matter of the dogs with ventriculomegaly (p = 0.0029 but not in the other ROIs. Reduction of periventricular CBF might imply increase of intraventricular pressure in ventriculomegaly.

  4. Developing a Benchmarking Process in Perfusion: A Report of the Perfusion Downunder Collaboration

    Science.gov (United States)

    Baker, Robert A.; Newland, Richard F.; Fenton, Carmel; McDonald, Michael; Willcox, Timothy W.; Merry, Alan F.

    2012-01-01

    Abstract: Improving and understanding clinical practice is an appropriate goal for the perfusion community. The Perfusion Downunder Collaboration has established a multi-center perfusion focused database aimed at achieving these goals through the development of quantitative quality indicators for clinical improvement through benchmarking. Data were collected using the Perfusion Downunder Collaboration database from procedures performed in eight Australian and New Zealand cardiac centers between March 2007 and February 2011. At the Perfusion Downunder Meeting in 2010, it was agreed by consensus, to report quality indicators (QI) for glucose level, arterial outlet temperature, and pCO2 management during cardiopulmonary bypass. The values chosen for each QI were: blood glucose ≥4 mmol/L and ≤10 mmol/L; arterial outlet temperature ≤37°C; and arterial blood gas pCO2 ≥ 35 and ≤45 mmHg. The QI data were used to derive benchmarks using the Achievable Benchmark of Care (ABC™) methodology to identify the incidence of QIs at the best performing centers. Five thousand four hundred and sixty-five procedures were evaluated to derive QI and benchmark data. The incidence of the blood glucose QI ranged from 37–96% of procedures, with a benchmark value of 90%. The arterial outlet temperature QI occurred in 16–98% of procedures with the benchmark of 94%; while the arterial pCO2 QI occurred in 21–91%, with the benchmark value of 80%. We have derived QIs and benchmark calculations for the management of several key aspects of cardiopulmonary bypass to provide a platform for improving the quality of perfusion practice. PMID:22730861

  5. Transmission of hepatitis-B virus through salivary blood group antigens in saliva

    International Nuclear Information System (INIS)

    Meo, S.A.; Abdo, A.A.; Baksh, N.D.; Sanie, F.M.

    2010-01-01

    To determine an association between transmission of hepatitis B virus and secretor and non-secretor status of salivary blood group antigens. Study Design: Cross-sectional, analytical study. Place and Duration of Study: The Department of Physiology and Division of Hepatology, College of Medicine, King Khalid University Hospital, King Saud University, Riyadh, Kingdom of Saudi Arabia, from 2007 to 2009. Methodology: Eighty eight known patients, who were positive for Hepatitis B Surface Antigen [HBsAg] were recruited. Saliva was collected for investigating the secretor and non-secretor status by using blood typing kit number Kemtec Educational Science USA. Hepatitis B Surface antigen test was performed on Enzyme Linked Immunosorbent Assay technique. Polymerase chain reaction [PCR] on saliva was also carried out in High Performance Thermal Cycler-Palm- Cycler [Corbett Life Science, Sydney, Australia] and enzymatic amplification of extracted viral DNA was performed using primers covering the promoter of the core region of HBV. Results: Out of the 88 subjects, 61 belong to blood group O, 20 to A and 7 subjects to blood group B. Fifty subjects were secretors [salivary blood group antigens positive] and 38 subjects were non-secretors [salivary blood group antigens negative]. Among core gene positive 25 (69.4%) were secretors and 11 (30.6%) were non-secretors. However, in core gene negative 25 (48.1%) were secretors and 27 (51.9%) were non-secretors. Conclusion: The result shows an association [p=0.047] between secretor and non-secretors status of the salivary blood group antigens with core gene positive and core gene negative. (author)

  6. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    Energy Technology Data Exchange (ETDEWEB)

    Bisdas, Sotirios [JWG University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nemitz, Ole; Becker, Hartmut; Donnerstag, Frank [Hannover Medical School, Department of Neuroradiology, Hannover (Germany); Berding, Georg [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Weissenborn, Karin; Ahl, Bjoern [Hannover Medical School, Department of Neurology, Hannover (Germany)

    2006-10-15

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [{sup 15}O]H{sub 2}O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  7. Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease

    International Nuclear Information System (INIS)

    Bisdas, Sotirios; Nemitz, Ole; Becker, Hartmut; Donnerstag, Frank; Berding, Georg; Weissenborn, Karin; Ahl, Bjoern

    2006-01-01

    Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [ 15 O]H 2 O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. (orig.)

  8. Isolated Liver Perfusion Using Percutaneous Methods:[ql An Experimental Study in the Pig

    International Nuclear Information System (INIS)

    Harnek, Jan; Cwikiel, Wojciech; Bergqvist, Lennart; Persson, Bo; Stridbeck, Hans

    1996-01-01

    Purpose: To develop a method for isolated perfusion of the liver using radiological methods. Methods: Twenty-one pigs, weighing about 20 kg, were divided into three groups. By transjugular and transfemoral approaches two occlusion balloons were placed in the inferior vena cava cranial and caudal, respectively, to the origin of the hepatic veins. One occlusion balloon was placed transfemorally in the common hepatic artery. Another occlusion balloon was inserted in the main branch of the portal vein via the transjugular-transhepatic approach in 11 pigs (groups 1 and 2), and in 10 pigs (group 3) by a percutaneous transhepatic route. After inflation of the balloons, patency of the isolated liver circulation was evaluated by recirculation of 99 Tc m -labelled human albumin during 30 min. Blood tests were obtained after 1, 3, 5, 10, 15, and 30 min to evaluate leakage from the liver to the systemic circulation. Results: Increasing leakage to the systemic circulation from the isolated liver circulation was observed in groups 1 and 2. In the third group the leakage was less than 10%. Conclusion: In an experimental animal model, isolated perfusion of the liver with minor leakage to the systemic circulation may be achieved using radiological methods

  9. Prevention of post-transfusion hepatitis c transmission through donor blood and its components

    Directory of Open Access Journals (Sweden)

    A. V. Chechetkin

    2015-01-01

    Full Text Available The aim of organizational aspects of preventing the transmission of hepatitis C virus with donor blood and its components.Materials and methods. An activity of the blood service establishments in Russia for the prevention of HCV infection through transfusion of blood and its components on the basis of the analysis of sectoral statistical surveys was studied.Results. The frequency of detection of antibodies to hepatitis C virus in blood donors and its components during 2009–2013 decreased by more than 1,5 times. The percentage of donors who have identified markers of hepatitis C virus was significantly different in different regions: from 0,51% to 1,36%. The activity of the blood service implemented method of plasma quarantine resulting annually rejected from 0,32% to 0,23% as a result of the identified markers of HCV. Pathogen inactivated plasma volume increased in 3 times, the platelet concentrate in 3,2 times.Conclusion. To ensure the safety of donated blood and its components in the blood service effectively the modern technology use for to prevention transmission of the HCV: quarantine of plasma, donor selection and development, inactivation of pathogens. The degree of implementation in practice of nonpaid voluntary blood transfusions significantly increased and is characterized by regional features in recent years .

  10. Pulsatile versus steady infusions for hepatic artery chemotherapy

    International Nuclear Information System (INIS)

    Kim, E.E.; Haynie, T.P.; Wright, K.C.; Chaynsangavej, C.; Gianturco, C.; Lamki, L.; Wallace, S.

    1984-01-01

    Hepatic artery chemotherapy for unresectable liver tumors requires an even distribution of the drugs in the tumor or vascular bed. This cannot be determined angiographically because the drugs are infused at a much lower rate than the contrast media. It is easy, however, to determine the quality of the perfusion by injecting a small volume of Tc-99m MAA in one of the side ports while chemotherapeutic agent is being infused at the same rate. Usually this shows a uniform, satisfactory distribution of isotope. Occasionally, however, some areas fail to receive Tc-99m in spite of what appears to be a good position of the catheter tip. Since ''streaming'' of the infused drugs has been blamed for their uneven distribution, the authors decided to compare the usual steady flow infusions with infusions made pulsatile by the addition of a pulsing device (Gianturco Pump) attached to the infusion tubing. Eighty-three patients were studied with steady as well as pulsatile infusions. In 16 of these patients the perfusion pattern was definitely changed by the pulsatile infusion. In one patient the pulsatile mode resulted in an unwanted gastric perfusion. In 5 patients the distribution was improved in one hepatic lobe and in 10 patients it was improved in both lobes. These results show that hepatic artery perfusions can occasionally be improved by pulsing the infusate. However, pulsing can produce the unwanted perfusion of extra-hepatic areas

  11. Downstream Hepatic Arterial Blood Pressure Changes Caused by Deployment of the Surefire AntiReflux Expandable Tip

    International Nuclear Information System (INIS)

    Rose, Steven C.; Kikolski, Steven G.; Chomas, James E.

    2013-01-01

    Purpose: The purpose of this work was to evaluate blood pressure changes caused by deployment of the Surefire antireflux expandable tip. The pressure measurements are relevant because they imply changes in hepatoenteric arterial blood flow within this liver compartment during hepatic artery delivery of cytotoxic agents. Methods: After positioning the Surefire antireflux system in the targeted hepatic artery, blood pressure was obtained initially with the tip collapsed (or through a femoral artery sheath), then again after the tip was expanded before chemoembolization or yttrium 90 ( 90 Y) radioembolization. Results: Eighteen patients with liver malignancy underwent 29 procedures in 29 hepatic arteries (3 common hepatic, 22 lobar, 4 segmental). Systolic, diastolic, and mean blood pressure were all decreased by a mean of 29 mm Hg (p = 0.000004), 14 mm Hg (p = 0.0000004), and 22 mm Hg (p = 0.00000001), respectively. Conclusion: When the Surefire expandable tip is deployed to prevent retrograde reflux of agents, it also results in a significant decrease in blood pressure in the antegrade distribution, potentially resulting in hepatopedal blood flow in vessels that are difficult to embolize, such as the supraduodenal arteries

  12. SEROPREVALENCE OF HEPATITIS C AMONG THE APPARENTLY HEALTHY BLOOD DONORS OF KARACHI

    Directory of Open Access Journals (Sweden)

    Maeesa Wadood

    2017-06-01

    Full Text Available Hepatitis C is a global health issue. Pakistan is among the prevalent countries for hepatitis C virus (HCV. Due to poverty, unemployment, low literacy rate, unawareness and poor health facilities, Pakistani population are susceptible to HCV transmission. As blood transfusion is a potential source of HCV; therefore, this study was designed to determine the recent seroprevalence of HCV among the healthy blood donors of Karachi, Pakistan. For this purpose, 536 blood donors were screened for anti- HCV antibodies by 3rd generation ELISA. The seroprevalence of HCV observed is 2.99% among healthy blood donors. Male predominance is noticed with seropositivity of 2.62%; however, only 0.37% female blood donors were reactive for anti-HCV antibodies. This study concludes that HCV frequency has been increased in the natives of Karachi, Pakistan when compared to the past studies. Therefore, it is recommended that the healthcare authorities should play a vital role in enforcing preventive measures for HCV transmission.

  13. Diversity and origin of hepatitis B virus in Dutch blood donors

    NARCIS (Netherlands)

    Koppelman, M. H. G. M.; Zaaijer, H. L.

    2004-01-01

    Two considerations led us to study the genetic diversity and origin of hepatitis B virus (HBV) in Dutch blood donors. Firstly, an HBV-infected Dutch blood donor was found negative by four assays used commonly for detection of HBV surface antigen (HBsAg). How variable is HBsAg among HBV infected

  14. Factors affecting the lung perfused blood volume in patients with intrapulmonary clots after anti-coagulation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa, E-mail: radokada@yamaguchi-u.ac.jp [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Masuda, Yu [4th Grade of 6-year Medicine Doctor Program, Department of Medicine, Yamaguchi University Faculty of Medicine and Health Sciences 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Nakashima, Yoshiteru [Department of Radiology, Yamaguchi Grand Medical Center, Oosaki 77, Hofu, Yamaguchi 747-8511 (Japan); Nomura, Takafumi; Nakao, Sei [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Suga, Kazuyoshi [Department of Radiology, St Hills Hospital, Imamurakita 3-7-18, Ube, Yamaguchi 755-0155 (Japan); Kido, Shoji [Computer-aided Diagnosis and Biomedical Imaging Research Biomedical Engineering, Applied Medical Engineering Science Graduate School of Medicine, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi 755-8611 (Japan); Matsunaga, Naofumi [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan)

    2015-08-15

    Highlights: • Dual-energy CT can provide morphological and functional lung images in the same examination. • The subsequent dual-energy CT demonstrates the increased whole lung perfused blood volume (V{sub 120}) despite the residual intrapulmonary clots after treatment in one examination. • The increased whole lung perfusion (V{sub 120}) and a decreased low perfusion volume (V{sub 5}) result in the improvement in the low perfusion rate (%V{sub 5}) in the patients with acute pulmonary embolism after treatment. - Abstract: Objectives: Factors affecting the improvement in the lung perfused blood volume (LPBV) were evaluated based on the presence of intrapulmonary clots (IPCs) after anti-coagulation therapy using 64-slice dual-energy CT. Materials and methods: 96 patients exhibiting venous thromboembolism underwent initial and repeated LPBV examinations between December 2008 and July 2014. Fifteen patients were excluded due to pulmonary comorbidities, and a total of 81 patients were included in this study. Acute pulmonary embolism (PE) was diagnosed in 46 of the patients (56.7%). LPBV images were three-dimensionally reconstructed with two threshold ranges: 1–120 HU (V{sub 120}) and 1–5 HU (V{sub 5}), and the relative value of V{sub 5} per V{sub 120} expressed as %V{sub 5}. These values were subsequently compared with indicators of the severity of PE, such as the D-dimer level, heart rate and CT measurements. This study was approved by the local ethics committee. Results: In patients with IPCs, the D-dimer, V{sub 5} and %V{sub 5}values were significantly larger (p ≤ 0.01) in the initial LPBV, although these differences disappeared in subsequent LPBV after treatment. The right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio and %V{sub 5} values were also significantly reduced, whereas the V{sub 5} value did not significantly decrease (p = 0.07), but V{sub 120} value significantly increased (p < 0.001) after treatment. However, in

  15. Effects of ethanol and hyperosmotic perfusates on albumin synthesis and release

    International Nuclear Information System (INIS)

    Rothschild, M.A.; Oratz, M.; Schreiber, S.S.; Mongelli, J.

    1986-01-01

    Sucrose and ethanol inhibit albumin synthesis; sucrose via an osmotic mechanism and ethanol during its metabolism. The present study was undertaken to compare the effects of both of these agents on albumin synthesis and secretion, and to see if ethanol inhibition could be related to an osmotic effect. Male, fed rabbits served as liver donors in all studies. There were a total of 35 studies: 13 control; 10 ethanol (39 to 52 mM); 4 cycloheximide (0.5 mM), and 8 sucrose (1%). Plasma volume was measured with 125 I-albumin (human) and extracellular volume measured with either /sup 99m/Tc diethylenetriamine pentaacetic acid or [ 14 C]sucrose. During perfusion, rabbit albumin content in the perfusate was measured immunologically every 15 to 30 min for 225 min. Interstitial albumin efflux was measured by the rate of appearance in the perfusate of 125 I-albumin given to 10 other rabbits 3 days prior to hepatic removal and perfusion. During the initial 75 min of perfusion, 74% of the in vivo equilibrated exchangeable 125 I-albumin appeared in the perfusate, and during this period the rabbit albumin that entered the perfusate was taken to represent efflux from the interstitial volume plus synthesis. Rabbit albumin appearing in the perfusate during the later period of 150 min was taken to represent mainly synthesis and was used to calculate the amount of albumin that would be synthesized in 75 min. The difference between these two values would be hepatic interstitial albumin appearing in the perfusate

  16. Dried blood spots, valid screening for viral hepatitis and human immunodeficiency virus in real-life

    DEFF Research Database (Denmark)

    Mössner, Belinda K; Staugaard, Benjamin; Jensen, Janne

    2016-01-01

    AIM: To detect chronic hepatitis B (CHB), chronic hepatitis C (CHC) and human immunodeficiency virus (HIV) infections in dried blood spot (DBS) and compare these samples to venous blood sampling in real-life. METHODS: We included prospective patients with known viral infections from drug treatment......, but correctly classified 95% of the anti-HCV-positive patients with chronic and past infections. Anti-HBc and anti-HBS showed low sensitivity in DBS (68% and 42%). CONCLUSION: DBS sampling, combined with an automated analysis system, is a feasible screening method to diagnose chronic viral hepatitis and HIV...

  17. Prevalence of hepatitis B virus and hepatitis C virus among blood donors at a tertiary care hospital in India: a five-year study.

    Science.gov (United States)

    Meena, Monika; Jindal, Tarun; Hazarika, Anjali

    2011-01-01

    Hepatitis B virus (HBV) and hepatitis C virus (HCV) are important transfusion-transmissible infections. This study was performed to assess the prevalence of HBV and HCV seropositivity among blood donors at a tertiary care hospital-based blood bank in India. The blood donation records over 5 years (2005-2009) were reviewed, retrospectively, for the prevalence and yearly trends of HBV and HCV seropositivity. A total of 94,716 donations were received. The overall number of HBV-seropositive donations was 1353 and that for HCV was 537, with the prevalence rates of 1.43% for hepatitis B surface antigen (HBsAg) and 0.57% for HCV. The seropositivity rate was higher in the replacement donors compared to the voluntary donors. The annual rates showed decreasing trends in case of HBsAg, but in case of HCV, there was a linear increase. Our study raises serious concerns regarding the HBV and HCV prevalence in our country. Although HBV showed decreasing trends, it cannot be relied upon because the donors were screened only for HBsAg. HCV is clearly on the rise. Stringent measures need to be taken on urgent basis including dissemination of information, strict screening of blood, inclusion of antibody to hepatitis B core antigen and other sensitive markers to the screening protocol, and better donor recruitment. © 2010 American Association of Blood Banks.

  18. Hepatitis isquémica Ischemic hepatitis

    Directory of Open Access Journals (Sweden)

    Marcos Amuchástegui (h

    2006-10-01

    Full Text Available La hepatitis isquémica es una complicación sumamente infrecuente de cirugía cardiovascular. Las biopsias muestran necrosis centrolobulillar. El término de "hepatitis" fue propuesto debido al aumento de transaminasas similar a aquellas de origen infeccioso, e "isquémica" por falla en la perfusión hepática. Posteriormente se definió el término de hepatitis isquémica como cuadro de elevación aguda y reversible (dentro de las 72 horas de transaminasas de hasta 20 veces el valor normal, asociado a trastornos en la perfusión hepática, luego de haber excluido otras causas de hepatitis aguda o daño hepatocelular. Se describe el caso de un paciente de 53 años que consulta por dolor epigástrico de 12 h de evolución sin fiebre, náuseas ni vómitos, resistente a la medicación. Tenía antecedentes inmediatos de reemplazo de válvula aórtica, y estaba anticoagulado. Evolucionó con shock y fallo multiorgánico. El examen evidenció marcada ictericia y signos de taponamiento pericárdico, asociado a un aumento considerable de enzimas hepáticas. Un ecocardiograma informó signos de taponamiento cardíaco y ausencia de disección aórtica. Se decidió pericardiocentesis, extrayéndose 970 cc. de líquido sanguinolento, y hemodiálisis, con notable mejoría de su estado hemodinámico. Los valores enzimáticos disminuyeron. Los marcadores virales fueron negativos.Ischemic hepatitis is an uncommon cardiovascular surgery complication. Hepatic biopsies show centrolobulillar necrosis. The term "hepatitis" was proposed because of a raise in hepatic enzymes similar with infectious disease, and "ischemic" because of failure in hepatic perfusion. Ischemic hepatitis was then defined as an acute and reversible elevation of hepatic enzymes (within 72 h, associated with disturbance in hepatic perfusion after excluding other causes of acute hepatitis. A 53 year-old male presented complaining of a 12 h epigastric pain, without nausea or vomiting, resistant

  19. Percutaneous Isolated Hepatic Perfusion as a Treatment for Isolated Hepatic Metastases of Uveal Melanoma: Patient Outcome and Safety in a Multi-centre Study

    International Nuclear Information System (INIS)

    Vogl, Thomas J.; Koch, Silvia A.; Lotz, Gösta; Gebauer, Bernhard; Willinek, Winfried; Engelke, Christoph; Brüning, Roland; Zeile, Martin; Wacker, Frank; Vogel, Arndt; Radeleff, Boris; Scholtz, Jan-Erik

    2017-01-01

    PurposePercutaneous isolated hepatic perfusion (PIHP) with Melphalan has been developed as a treatment for patients with isolated hepatic metastases of uveal melanoma. We discuss patient outcome and safety in a retrospective multi-centre study.Materials and MethodsBetween 2012 and 2016 18 patients with un-resectable isolated hepatic metastases of uveal melanoma received single or repeated PIHP with Melphalan (n = 35) at seven sites. Progression-free time, overall survival time (OS) and tumour response by means of RECIST 1.1 criteria were evaluated. Peri- and post-procedural adverse events (AE) were registered. Patients’ life quality was assessed using four-point scale questionnaires.ResultsOf 18 patients, initial PIHP treatment resulted in partial response (PR) in eight, stable disease (SD) in seven and progressive disease (PD) in three cases. Nine patients underwent second PIHP with PR in eight cases and PD in one case. Six patients were evaluated after third PIHP with PR in five patients and SD in one patient. Two patients received fourth PIHP with PD in both cases. Median OS was 9.6 months (range 1.6–41.0 months). Median progression-free survival time was 12.4 months (range 0.9–41.0 months) with 1-year survival of 44%. Most common post-procedural AE grade 3 and 4 were temporary leukopenia (n = 11) and thrombocytopenia (n = 8). Patients’ self-assessments showed good ratings for overall health and quality of life with only slight changes after PIHP, and a high degree of satisfaction with PIHP treatment.ConclusionPIHP with Melphalan proved to be a relatively safe, minimal-invasive and repeatable treatment for patients with non-resectable hepatic metastases of uveal melanoma.

  20. Percutaneous Isolated Hepatic Perfusion as a Treatment for Isolated Hepatic Metastases of Uveal Melanoma: Patient Outcome and Safety in a Multi-centre Study

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J., E-mail: t.vogl@em.uni-frankfurt.de; Koch, Silvia A., E-mail: silvia.koch@web.de [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology (Germany); Lotz, Gösta, E-mail: goesta.lotz@kgu.de [University Hospital Frankfurt, Department of Anesthesiology, Intensive-Care Medicine and Pain Therapy (Germany); Gebauer, Bernhard, E-mail: bernhard.gebauer@charite.de [Universitätsmedizin Berlin, Department of Diagnostic and Interventional Radiology, Campus Charité Mitte (Germany); Willinek, Winfried, E-mail: w.willinek@bk-trier.de [Brüderkrankenhaus Trier, Department of Diagnostic and Interventional Radiology (Germany); Engelke, Christoph, E-mail: engelke@ekweende.de [Evangelisches Krankenhaus Göttingen-Weende gGmbH, Department of Diagnostic and Interventional Radiology (Germany); Brüning, Roland, E-mail: r.bruening@asklepios.com; Zeile, Martin, E-mail: m.zeile@asklepios.com [Asklepios Klinik Barmbek, Department of Diagnostic and Interventional Radiology (Germany); Wacker, Frank, E-mail: wacker.frank@mh-hannover.de [Medizinische Hochschule Hannover, Department of Diagnostic and Interventional Radiology (Germany); Vogel, Arndt, E-mail: vogel.arndt@mh-hannover.de [Medizinische Hochschule Hannover, Department of Gastroenterology, Hepatology and Endocrinology (Germany); Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de [Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology (Germany); Scholtz, Jan-Erik, E-mail: janerikscholtz@gmail.com [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposePercutaneous isolated hepatic perfusion (PIHP) with Melphalan has been developed as a treatment for patients with isolated hepatic metastases of uveal melanoma. We discuss patient outcome and safety in a retrospective multi-centre study.Materials and MethodsBetween 2012 and 2016 18 patients with un-resectable isolated hepatic metastases of uveal melanoma received single or repeated PIHP with Melphalan (n = 35) at seven sites. Progression-free time, overall survival time (OS) and tumour response by means of RECIST 1.1 criteria were evaluated. Peri- and post-procedural adverse events (AE) were registered. Patients’ life quality was assessed using four-point scale questionnaires.ResultsOf 18 patients, initial PIHP treatment resulted in partial response (PR) in eight, stable disease (SD) in seven and progressive disease (PD) in three cases. Nine patients underwent second PIHP with PR in eight cases and PD in one case. Six patients were evaluated after third PIHP with PR in five patients and SD in one patient. Two patients received fourth PIHP with PD in both cases. Median OS was 9.6 months (range 1.6–41.0 months). Median progression-free survival time was 12.4 months (range 0.9–41.0 months) with 1-year survival of 44%. Most common post-procedural AE grade 3 and 4 were temporary leukopenia (n = 11) and thrombocytopenia (n = 8). Patients’ self-assessments showed good ratings for overall health and quality of life with only slight changes after PIHP, and a high degree of satisfaction with PIHP treatment.ConclusionPIHP with Melphalan proved to be a relatively safe, minimal-invasive and repeatable treatment for patients with non-resectable hepatic metastases of uveal melanoma.

  1. Comparative study of portal hemodynamics and regional hepatic blood flow before and after hepatic resection by 133Xe-scintiphotosplenoportography

    International Nuclear Information System (INIS)

    Yasuda, Tadashi; Sasaki, Yo; Imaoka, Shingi; Shibata, Takashi; Wada, Hisashi; Nagano, Hiroaki; Iwanaga, Takeshi; Nakano, Shunichi; Hasegawa, Yoshihisa.

    1990-01-01

    Changes in the portal circulatory pattern and regional hepatic blood flow (rHBF) after surgical liver resection were studied by 133 Xe-scintiphotosplenoportography (SSP). The visual patterns of pre- and postoperative portal circulation were compared. Different patterns were observed after the operation in five of 27 patients (porto-systemic shunt formation 3, progression 1, regression 1). The patients with porto-systemic shunt showed postopertive complications (massive ascites, jaundice, cardiopulmonary failure) more frequently than those without it. The ratio of rHBF increase (post-/pre-operative rHBF) was 1.36±0.63 on average. The ratio was higher in patients with good liver function or without liver cirrhosis. The ratio also correlated with the weight of the liver resected. But operation time, blood loss or whether hepatic blood supply was clamped off during the operation did not affect the ratio. Resection in the right lobe, however, caused a greater rHBF increase in the residual liver than the same degree of resection in the left lobe. SSP could be a useful method for investigating the effect of hepatic resection on portal hemodynamics and it is suggested that existence of portosystemic shunt influences the postoperative course. (author)

  2. Blood transfusion and hepatitis viruses | Bird | South African Medical ...

    African Journals Online (AJOL)

    Transmission of hepatitis viruses has been recognised as an undesirable effect of blood transfusion since the 1940s, when large outbreaks occurred following inoculation with a yellow fever vaccine which contained pooled human plasma. Further reports followed of jaundice occurring several months after transfusions with ...

  3. Effect of intranasally administered insulin on cerebral blood flow and perfusion

    DEFF Research Database (Denmark)

    Akintola, Abimbola A.; van Opstal, Anna M.; Westendorp, Rudi G.

    2017-01-01

    Insulin, a vasoactive modulator regulating peripheral and cerebral blood flow, has been consistently linked to aging and longevity. In this proof of principle study, using a randomized, double-blinded, placebo-controlled crossover design, we explored the effects of intranasally administered insulin...... labelling. Total flow through the major cerebropetal arteries was unchanged in both young and old. In the older participants, intranasal insulin compared to placebo increased perfusion through the occipital gray matter (65.2±11.0 mL/100g/min vs 61.2±10.1 mL/100g/min, P=0.001), and in the thalamus (68...

  4. Microvascular Architecture of Hepatic Metastases in a Mouse Model

    Directory of Open Access Journals (Sweden)

    Darshini Kuruppu

    1997-01-01

    Full Text Available Development of effective treatment for hepatic metastases can be initiated by a better understanding of tumour vasculature and blood supply. This study was designed to characterise the microvascular architecture of hepatic metastases and observe the source of contributory blood supply from the host. Metastases were induced in mice by an intrasplenic injection of colon carcinoma cells (106 cells/ml. Vascularization of tumours was studied over a three week period by scanning electron microscopy of microvascular corrosion casts. Metastatic liver involvement was observed initially within a week post induction, as areas approximately 100 μm in diameter not perfused by the casting resin. On histology these spaces corresponded to tumour cell aggregates. The following weeks highlighted the angiogenesis phase of these tumours as they received a vascular supply from adjacent hepatic sinusoids. Direct sinusoidal supply of metastases was maintained throughout tumour growth. At the tumour periphery most sinusoids were compressed to form a sheath demarcating the tumour from the hepatic vasculature. No direct supply from the hepatic artery or the portal vein was observed. Dilated vessels termed vascular lakes dominated the complex microvascular architecture of the tumours, most tapering as they traversed towards the periphery. Four vascular branching patterns could be identified as true loops, bifurcations and trifurcations, spirals and capillary networks. The most significant observation in this study was the direct sinusoidal supply of metastases, together with the vascular lakes and the peripheral sinusoidal sheaths of the tumour microculature.

  5. Risk Factors for Hepatitis C Virus Infection among Blood Donors in Georgia

    International Nuclear Information System (INIS)

    Zaller, Nickolas; Nelson, Kenrad E.; Aladashvili, Malvina; Badridze, Nino; Rio, Carlos del; Tsertsvadze, Tengiz

    2004-01-01

    Background: Growing awareness about the importance of blood safety for controlling the transmission of hepatitis C virus (HCV) has helped to decrease the spread of this virus in many settings. This study was conducted in order to evaluate potential risk factors for HCV infection among blood donors in Georgia. Methods: The study population consisted of 553 blood donors in three major Georgian cities; Tbilisi, the capital city and Batumi and Poti, naval port cities. Risk factors were examined using a behavior questionnaire. All blood samples were initially tested using 3rd generation anti-HCV enzyme-linked immunosorbent assays and confirmed using recombinant immunoblot assays and nucleic acid testing. Results: Forty-three blood donors, 7.8%, were confirmed HCV positive. Significant risk factors included: drug injection ever (OR: 42; 95% CI: 3.2-550.7); history of hepatitis (OR: 25.9; 95% CI: 4.6-145.5); history of a previous surgical procedure (OR: 148.4; 95% CI: 26.9-817.4); blood transfusion (OR: 25.9; 95% CI: 3.2-210.9). Conclusions: This study found a very high prevalence of HCV among blood donors in Georgia. The main risk factor for HCV infection in this population of blood donors was previous contact with contaminated blood or blood products. Reliable screening of donors and their blood is critical for controlling the further spread of HCV in Georgia

  6. Hepatic entropy and uniformity: additional parameters that can potentially increase the effectiveness of contrast enhancement during abdominal CT

    International Nuclear Information System (INIS)

    Ganeshan, B.; Miles, K.A.; Young, R.C.D.; Chatwin, C.R.

    2007-01-01

    Aim: To determine how hepatic entropy and uniformity of computed tomography (CT) images of the liver change after the administration of contrast material and to assess whether these additional parameters are more sensitive to tumour-related changes in the liver than measurements of hepatic attenuation or perfusion. Materials and methods: Hepatic attenuation, entropy, uniformity, and perfusion were measured using multi-phase CT following resection of colorectal cancer. Based on conventional CT and fluorodeoxyglucose positron emission tomography, 12 patients were classified as having no evidence of malignancy, eight with extra-hepatic tumours only, and eight with metastatic liver disease. Results: Hepatic attenuation and entropy increased after CM administration whereas uniformity decreased. Unlike hepatic attenuation, entropy and uniformity changed maximally in the arterial phase. No significant differences in hepatic perfusion or attenuation were found between patient groups, whereas arterial-phase entropy was lower (p = 0.034) and arterial-phase uniformity was higher (p = 0.034) in apparently disease-free areas of liver in patients with hepatic metastases compared with those with no metastases. Conclusion: Temporal changes in hepatic entropy and uniformity differ from those for hepatic attenuation. By reflecting the distribution of hepatic enhancement, these additional parameters are more sensitive to tumour-related changes in the liver than measurements of hepatic attenuation or perfusion

  7. HEPATITIS B PREVALENCE AMONG BLOOD DONORS AT A TERTIARY CARE CENTRE IN MYSORE

    Directory of Open Access Journals (Sweden)

    Sreenivas

    2015-02-01

    Full Text Available BACKGROUND: Blood transfusion is an essential element of a health care system. Safety of blood transfusion is of extreme importance in order to avoid any severe morbidity and mortality in the patient. By screening donated blood units, we get a clue of the prevalence of those infections among donor pop ulations and consequently the safety of collected donations. It also gives us an idea of the prevalence of the Transfusion transmissible infections ( TTIs in the community. OBJECTIVES : To find out the sero - prevalence of TTIs namely HBV (Hepatitis B in the blood donor population at MMC&RI, Mysore. To stratify sero prevalence of TTIs based on the age and sex of the donor population . METHODOLOGY: The present study was carried out in the Blood Bank , Mysore Medical College and Research Institute , Mysore during the period from November 2012 to May 2014 among 14075 blood donors. All the samples were screened for hepatitis B surface antigen (HBsAg by ELISA method . RESULTS : Out of a total of 14075 blood donors , a total of 103 tested positive for TTIs . 94.08% were males and remaining 5.92% were females. A majority of donors were voluntary donors (85.79% and a majority of the donors were between the age group of 18 - 39 years (78.17%. The prevalence rate of HBV in blood donors was 0.73%. The seroprevale nce in voluntary donors was 0.57% and in replacement donors was 1.75 % respectively. CONCLUSION : Voluntary blood donation is safe, compared to replacement as high prevalence of Hepatitis B is observed in replacement donors.

  8. Thermal behavior of human eye in relation with change in blood perfusion, porosity, evaporation and ambient temperature.

    Science.gov (United States)

    Rafiq, Aasma; Khanday, M A

    2016-12-01

    Extreme environmental and physiological conditions present challenges for thermal processes in body tissues including multi-layered human eye. A mathematical model has been formulated in this direction to study the thermal behavior of the human eye in relation with the change in blood perfusion, porosity, evaporation and environmental temperatures. In this study, a comprehensive thermal analysis has been performed on the multi-layered eye using Pennes' bio-heat equation with appropriate boundary and interface conditions. The variational finite element method and MATLAB software were used for the solution purpose and simulation of the results. The thermoregulatory effect due to blood perfusion rate, porosity, ambient temperature and evaporation at various regions of human eye was illustrated mathematically and graphically. The main applications of this model are associated with the medical sciences while performing laser therapy and other thermoregulatory investigation on human eye. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Regional blood perfusion in childhood partial seizure using N-isopropyl-p-[I-123]iodoamphetamine and single photon emission CT

    International Nuclear Information System (INIS)

    Michihiro, Narumi; Kurosawa, Yumiko; Hibio, Shuichi; Ishihara, Hiroaki; Ariizumi, Motomizu

    1989-01-01

    Single photon emission CT (SPECT) with N-isopropyl-p-[I-123]iodoamphetamine was performed in 20 pediatric patients with partial seizure to examine regional blood perfusion. In detecting location of abnormality, SPECT and EEG were concordant in 13 patients (65%) and discordant in 4 patients (20%). In 7 patients undergoing SPECT one to 4 years after seizure onset, decreased blood perfusion corresponded to focal abnormality on EEG. In other 9 patiets in whom SPECT was performed within one year, however, location of abnormality on SPECT did not necessarily concur with that on EEG. These findings suggest that brain lesions are not focal but extensive at the early stage of partial seizure and that they are becoming focal with the mature of the central nervous system. (Namekawa, K)

  10. Metabolite kinetics: formation of acetaminophen from deuterated and nondeuterated phenacetin and acetanilide on acetaminophen sulfation kinetics in the perfused rat liver preparation

    International Nuclear Information System (INIS)

    Pang, K.S.; Waller, L.; Horning, M.G.; Chan, K.K.

    1982-01-01

    The role of hepatic intrinsic clearance for metabolite formation from various precursors on subsequent metabolite elimination was was investigated in the once-through perfused rat liver preparation. Two pairs of acetaminophen precursors: [ 14 C] phenacetin-d5 and [ 3 H] phenacetin-do, [ 14 C] acetanilide and [ 3 H] phenacetin were delivered by constant flow (10 ml/min/liver) either by normal or retrograde perfusion to the rat liver preparations. The extents of acetaminophen sulfation were compared within the same preparation. The data showed that the higher the hepatocellular activity (intrinsic clearance) for acetaminophen formation, the greater the extent of subsequent acetaminophen sulfation. The findings were explained on the basis of blood transit time and metabolite duration time. Because of blood having only a finite transit time in liver, the longer the drug requires for metabolite formation, the less time will remain for metabolite sulfation and the less will be the degree of subsequent sulfation. Conversely, when the drug forms the primary metabolite rapidly, a longer time will remain for the metabolite to be sulfated in liver to result in a greater degree of metabolite sulfation. Finally, the effects of hepatic intrinsic clearances for metabolite formation and zonal distribution of enzyme systems for metabolite formation and elimination in liver are discussed

  11. Isolated hepatic perfusion as a treatment for uveal melanoma liver metastases (the SCANDIUM trial)

    DEFF Research Database (Denmark)

    Olofsson, Roger; Ny, Lars; Eilard, Malin Sternby

    2014-01-01

    for patients with liver metastases is between 6 and 12 months, and no treatment has in randomized trials ever been shown to prolong survival. A previous phase II trial using isolated hepatic perfusion (IHP) has suggested a 14-month increase in overall survival compared with a historic control group consisting...... of the longest surviving patients in Sweden during the same time period (26 versus 12 months). METHODS/DESIGN: This is the protocol for a multicenter phase III trial randomizing patients with isolated liver metastases of uveal melanoma to IHP or best alternative care (BAC). Inclusion criteria include liver....... The planned sample size is 78 patients throughout five years. DISCUSSION: Patients with isolated liver metastases of uveal melanoma origin have a short expected survival and no standard treatment option exists. This is the first randomized clinical trial to evaluate IHP as a treatment option with overall...

  12. Bacterial lipopolysaccharide-induced systemic inflammation alters perfusion of white matter-rich regions without altering flow in brain-irrigating arteries: Relationship to blood-brain barrier breakdown?

    Science.gov (United States)

    Dhaya, Ibtihel; Griton, Marion; Raffard, Gérard; Amri, Mohamed; Hiba, Bassem; Konsman, Jan Pieter

    2018-01-15

    To better understand brain dysfunction during sepsis, cerebral arterial blood flow was assessed with Phase Contrast Magnetic Resonance Imaging, perfusion with Arterial Spin Labeling and structure with diffusion-weighted Magnetic Resonance Imaging in rats after intraperitoneal administration of bacterial lipopolysaccharides. Although cerebral arterial flow was not altered, perfusion of the corpus callosum region and diffusion parallel to its fibers were higher after lipopolysaccharide administration as compared to saline injection. In parallel, lipopolysaccharide induced perivascular immunoglobulin-immunoreactivity in white matter. These findings indicate that systemic inflammation can result in increased perfusion, blood-brain barrier breakdown and altered water diffusion in white matter. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Hepatic VX2 tumor after portal vein occlusion in rabbits: evaluation with DSA

    International Nuclear Information System (INIS)

    Qi Yueyong; Zou Liguang; Dai Shuhua; Zhang Qichuan; Chen Lin; Huang Xiaobing; Huan Guangqiang

    2006-01-01

    Objective: To study the value of DSA for hepatic vascular anatomy, and to evaluate the efficacy of portal vein occlusion in rabbits with hepatic VX2 tumor. Methods: Twenty New Zealand white rabbits were randomly divided into two groups with 10 in each group, including test group A and positive control group B of ham operation. For the test group A, portal branch ligation (PBL) was performed for the left external branch after 3 weeks of the tumor implantation to the left external lobe. Two weeks later, the DSA of hepatic artery and portal vein were performed in all of the rabbits. Results: The total displaying effectiveness of the branches of hepatic artery by DSA was better than that by vascular perfusion. There was hypovascular blood supply to hepatic artery implantation of the tumor in the test group A, comparing with that of the group B. Conclusion: DSA can clearly display special details of the hepatic vascular anatomy in rabbits, and play an important role in post-procedural evaluation of the portal vein occlusion in rabbits. (authors)

  14. Computed tomography arterial portography for assessment of portal vein injury after blunt hepatic trauma.

    Science.gov (United States)

    Fu, Chen Ju; Wong, Yon Cheong; Tsang, Yuk Ming; Wang, Li Jen; Chen, Huan Wu; Ku, Yi Kang; Wu, Cheng Hsien; Chen, Huan Wen; Kang, Shih Ching

    2015-01-01

    Intrahepatic portal vein injuries secondary to blunt abdominal trauma are difficult to diagnose and can result in insidious bleeding. We aimed to compare computed tomography arterial portography (CTAP), reperfusion CTAP (rCTAP), and conventional computed tomography (CT) for diagnosing portal vein injuries after blunt hepatic trauma. Patients with blunt hepatic trauma, who were eligible for nonoperative management, underwent CTAP, rCTAP, and CT. The number and size of perfusion defects observed using the three methods were compared. A total of 13 patients (seven males/six females) with a mean age of 34.5±14.1 years were included in the study. A total of 36 hepatic segments had perfusion defects on rCTAP and CT, while there were 47 hepatic segments with perfusion defects on CTAP. The size of perfusion defects on CT (239 cm3; interquartile range [IQR]: 129.5, 309.5) and rCTAP (238 cm3; IQR: 129.5, 310.5) were significantly smaller compared with CTAP (291 cm3; IQR: 136, 371) (both, P = 0.002). Perfusion defects measured by CTAP were significantly greater than those determined by either rCTAP or CT in cases of blunt hepatic trauma. This finding suggests that CTAP is superior to rCTAP and CT in evaluating portal vein injuries after blunt liver trauma.

  15. Volume perfusion CT imaging of cerebral vasospasm: diagnostic performance of different perfusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Ahmed E. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Radiology, Tuebingen (Germany); Afat, Saif; Nikoubashman, Omid; Mueller, Marguerite; Wiesmann, Martin; Brockmann, Carolin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Schubert, Gerrit Alexander [RWTH Aachen University, Department of Neurosurgery, Aachen (Germany); Bier, Georg [Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Brockmann, Marc A. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); University Hospital Mainz, Department of Neuroradiology, Mainz (Germany)

    2016-08-15

    In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting <50 %, 2 - vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting < 50 %, 2 - vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm. (orig.)

  16. Hepatitis C virus infection may lead to slower emergence of P. falciparum in blood.

    Directory of Open Access Journals (Sweden)

    Odile Ouwe-Missi-Oukem-Boyer

    Full Text Available BACKGROUND: Areas endemic for Plasmodium falciparum, hepatitis B virus (HBV and hepatitis C virus (HCV overlap in many parts of sub-Saharan Africa. HBV and HCV infections develop in the liver, where takes place the first development stage of P. falciparum before its further spread in blood. The complex mechanisms involved in the development of hepatitis may potentially influence the development of the liver stage of malaria parasites. Understanding the molecular mechanisms of these interactions could provide new pathophysiological insights for treatment strategies in Malaria. METHODOLOGY: We studied a cohort of 319 individuals living in a village where the three infections are prevalent. The patients were initially given a curative antimalarial treatment and were then monitored for the emergence of asexual P. falciparum forms in blood, fortnightly for one year, by microscopy and polymerase chain reaction. PRINCIPAL FINDINGS: At inclusion, 65 (20.4% subjects had detectable malaria parasites in blood, 36 (11.3% were HBV chronic carriers, and 61 (18.9% were HCV chronic carriers. During follow-up, asexual P. falciparum forms were detected in the blood of 203 patients. The median time to P. falciparum emergence in blood was respectively 140 and 120 days in HBV- and HBV+ individuals, and 135 and 224 days in HCV- and HCV+ individuals. HCV carriage was associated with delayed emergence of asexual P. falciparum forms in blood relative to patients without HCV infection. CONCLUSIONS: This pilot study represents first tentative evidence of a potential epidemiological interaction between HBV, HCV and P. falciparum infections. Age is an important confounding factor in this setting however multivariate analysis points to an interaction between P. falciparum and HCV at the hepatic level with a slower emergence of P. falciparum in HCV chronic carriers. More in depth analysis are necessary to unravel the basis of hepatic interactions between these two pathogens

  17. Validation of Perfusion Quantification with 3D Gradient Echo Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Blood Pool Contrast Agent in Skeletal Swine Muscle.

    Directory of Open Access Journals (Sweden)

    Stefan Hindel

    Full Text Available The purpose of our study was to validate perfusion quantification in a low-perfused tissue by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI with shared k-space sampling using a blood pool contrast agent. Perfusion measurements were performed in a total of seven female pigs. An ultrasonic Doppler probe was attached to the right femoral artery to determine total flow in the hind leg musculature. The femoral artery was catheterized for continuous local administration of adenosine to increase blood flow up to four times the baseline level. Three different stable perfusion levels were induced. The MR protocol included a 3D gradient-echo sequence with a temporal resolution of approximately 1.5 seconds. Before each dynamic sequence, static MR images were acquired with flip angles of 5°, 10°, 20°, and 30°. Both static and dynamic images were used to generate relaxation rate and baseline magnetization maps with a flip angle method. 0.1 mL/kg body weight of blood pool contrast medium was injected via a central venous catheter at a flow rate of 5 mL/s. The right hind leg was segmented in 3D into medial, cranial, lateral, and pelvic thigh muscles, lower leg, bones, skin, and fat. The arterial input function (AIF was measured in the aorta. Perfusion of the different anatomic regions was calculated using a one- and a two-compartment model with delay- and dispersion-corrected AIFs. The F-test for model comparison was used to decide whether to use the results of the one- or two-compartment model fit. Total flow was calculated by integrating volume-weighted perfusion values over the whole measured region. The resulting values of delay, dispersion, blood volume, mean transit time, and flow were all in physiologically and physically reasonable ranges. In 107 of 160 ROIs, the blood signal was separated, using a two-compartment model, into a capillary and an arteriolar signal contribution, decided by the F-test. Overall flow in hind leg muscles

  18. Changes in distribution of hepatic blood flow induced by intra-arterial infusion of angiotensin II in human hepatic cancer

    International Nuclear Information System (INIS)

    Sasaki, Y.; Imaoka, S.; Hasegawa, Y.

    1985-01-01

    Changes in the distribution of the hepatic blood flow induced by intra-arterial infusion of angiotensin II (AT-II) were studied in human hepatic cancers using extremely short-lived radioisotope (RI) (krypton 81 m [/sup 81m/Kr]; half-life, 13 seconds). After the start of continuous infusion of AT-II, the radioactivity of the tumor showed about a two-fold increase, whereas that of the nontumor region decreased to about one half as much as the level before the infusion. Consequently, the mean ratio of the arterial blood flow in the tumor region to that in the nontumor region (T/N ratio) increased to 3.30 (P less than 0.001). The T/N ratio showed a peak before the peripheral blood pressure reached the maximum, and thereafter tended to decrease. Intra-arterial infusion of AT-II raised the T/N ratio more obviously than did intravenous infusion of the drug, with less rise in the peripheral blood pressure. It is believed that intra-arterial infusion chemotherapy with local use of AT-II enables better accessibility of chemotherapeutic drugs to tumors

  19. Effect of steroid on brain tumors and surround edemas : observation with regional cerebral blood volume (rCBV) maps of perfusion MRI

    International Nuclear Information System (INIS)

    Choi, Ju Youl; Sun, Joo Sung; Kim, Sun Yong; Kim, Ji Hyung; Suh, Jung Ho; Cho, Kyung Gi; Kim, Jang Sung

    2000-01-01

    To observe the hemodynamic change in brain tumors and peritumoral edemas after steroid treatment, and then investigate the clinical usefulness of perfusion MRI. We acquired conventional and perfusion MR images in 15 patients with various intracranial tumors (4 glioblastoma multiformes, 4 meningiomas, 3 metastatic tumors, 1 anaplastic ependymoma, 1 anaplastic astrocytoma, 1 hemangioblastoma, and 1 pilocytic astrocytoma). For perfusion MR imaging, a 1.5T unit employing the gradient-echo EPI technique was used, and further perfusion MR images were obtained 2-10 days after intravenous steroid therapy. After processing of the raw data, regional cerebral blood volume (rCBV) maps were reconstructed. The maps were visually evaluated by comparing relative perfusion in brain tumors and peritumoral edemas with that in contralateral white matter. Objective evaluations were performed by comparing the perfusion ratios of brain tumors and peritumoral edemas. Visual evaluations of rCBV maps, showed that in most brain tumors (67%, 10/15), perfusion was high before steroid treatment and showed in (80%, 12/15) decreased afterwards. Objective evaluation, showed that in all brain tumors, perfusion decreased. Visual evaluation of perfusion change in peritumoral edemas revealed change in only one case, but objective evaluation indicated that perfusion decreased significantly in all seven cases. rCBV maps acquired by perfusion MR imaging can provide hemodynamic information about brain tumors and peritumoral edemas. Such maps could prove helpful in the preoperative planning of brain tumor surgery and the monitoring of steroid effects during conservative treatment. (author)

  20. Characteristics of breast cancer blood supply before and after chemotherapy with low-dose CT perfusion

    International Nuclear Information System (INIS)

    Zhou Juan; Lu Hong; Sheng Fugeng; Xing Xudong; Li Gongjie; Liu Baosheng

    2009-01-01

    Objective: To analyze the characteristics of breast cancer blood supply before and after chemotherapy with low-dose CT perfusion. Methods: Fifteen patients with breast cancer underwent CT breast perfusion examination, which was performed before and after chemotherapy within 1 week on Siemens Sensation 4 scanner with 120 kV and 50 mAs, 50 ml of nonionic contrast agent (320 mg I/ml) was injected at a flow rate of 4 ml/s with a power injector, Scan started after 8 seconds delay and data acquisition duration was 50 seconds. The blood flow (BF), blood volume (BV) and mean transfer time (MTT) of lesion and contralateral normal breast gland were calculated using Basama perfusion 3 software package before and after chemotherapy. At the same time, the tumor size before and after chemotherapy were measured and correlated with the BF values. The t test and non-parametric test were used for the statistics. Results: (1) The mean BF, BV and MTT of breast cancer were (33.20±4.17) ml·min -1 ·100 ml -1 , (8.31±2.43) ml· 100 ml -1 and (15.31±4.31) s respectively before chemotherapy, and (13.65±6.04) ml·min -1 · 100 ml -1 (5.04±2.33) ml·100 ml -1 and (25.97±9.07) s respectively after chemotherapy and there were statistically significant (P=0.000). The mean BF, BV and MTT of normal breast were (4.31±2.23) ml -1 , min -1 ·100 ml -1 , (1.38±0.75) ml·100 ml -1 and ( 19.25±3.94) s respectively before chemotherapy, and (4.03±2.35) ml·min -1 ·100 ml -1 , (1.44±0.84) ml·100 ml -1 , (22.56±7.71 ) s respectively after chemotherapy and there were not statistically significant (P>0.05). (2)The BF of breast cancer was higher than the normal breast before chemotherapy (P<0.01). (3)There was a positive correlation between the BF values and tumor size before and after chemotherapy (r=0.902, P=0.000). Conclusion: The BF value has a positive correlation with tumor size after chemotherapy, CT perfusion is more sensitive for the evaluation of chemotherapy response than morphologic

  1. Changes in duration of action of rocuronium following decrease in hepatic blood flow during pneumoperitoneum for laparoscopic gynaecological surgery.

    Science.gov (United States)

    Liu, Yang; Cao, Wen; Liu, Yu; Wang, Yun; Lang, Ren; Yue, Yun; Wu, An-Shi

    2017-03-20

    A moderate insufflation pressure and deep neuromuscular blockade (NMB) have been recommended in laparoscopic surgery in consideration of the possible reduction in splanchnic perfusion due to the CO 2 -pneumoperitoneum. Since the liver is the major organ for rocuronium metabolism, the question of whether NMB of rocuronium would change with the variation of liver perfusion during pneumoperitoneum during laparoscopic surgery merits investigation. In this prospective study, a total of sixty female patients scheduled for either selective laparoscopic gynaecological surgery (group laparoscopy) or laparotomy for gynaecological surgery (group control) were analyzed. Rocuronium was administered with closed-loop feedback infusion system, which was also applied to monitor NMB complied with good clinical research practice (GCRP). The onset time, clinical duration, and recovery index were measured. Hepatic blood flow was assessed by laparoscopic intraoperative ultrasonography before insufflation/after entering the abdominal cavity (T1), 5 min after insufflation in the Trendelenburg position/5 min after skin incision (T2), 15 min after insufflation in the Trendelenburg position/15 min after skin incision (T3), 30 min after insufflation in the Trendelenburg position/30 min after skin incision (T4), and 5 min after deflation/before closing the abdomen (T5) in group laparoscopy/group control respectively. The relationship between the clinical duration of rocuronium and portal venous blood flow was analyzed using linear or quadratic regression. The clinical duration and RI of rocuronium were both prolonged significantly in group laparoscopy (36.8 ± 8.3 min; 12.8 ± 5.5 min) compared to group control (29.0 ± 5.8 min; 9.8 ± 4.0 min) (P rocuronium and portal venous blood flow (Y = 51.800-0.043X + (1.86E-005) X 2 ; r 2  = 0.491; P Rocuronium-induced NMB during laparoscopic gynaecological surgery might be prolonged due to the decrease in portal

  2. MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: noninvasive regional assessment of renal function.

    Science.gov (United States)

    Wentland, Andrew L; Artz, Nathan S; Fain, Sean B; Grist, Thomas M; Djamali, Arjang; Sadowski, Elizabeth A

    2012-01-01

    Magnetic resonance imaging (MRI) may be a useful adjunct to current methods of evaluating renal function. MRI is a noninvasive imaging modality that has the ability to evaluate the kidneys regionally, which is lacking in current clinical methods. Other investigators have evaluated renal function with MRI-based measurements, such as with techniques to measure cortical and medullary perfusion, oxygen bioavailability and total renal blood flow (TRBF). However, use of all three techniques simultaneously, and therefore the relationships between these MRI-derived functional parameters, have not been reported previously. To evaluate the ability of these MRI techniques to track changes in renal function, we scanned 11 swine during a state of hyperperfusion with acetylcholine and a saline bolus and subsequently scanned during a state of hypoperfusion with the prolonged use of isoflurane anesthesia. For each time point, measurements of perfusion, oxygen bioavailability and TRBF were acquired. Measurements of perfusion and oxygen bioavailability were compared with measurements of TRBF for all swine across all time points. Cortical perfusion, cortical oxygen bioavailability, medullary oxygen bioavailability and TRBF significantly increased with the acetylcholine challenge. Cortical perfusion, medullary perfusion, cortical oxygen bioavailability and TRBF significantly decreased during isoflurane anesthesia. Cortical perfusion (Spearman's correlation coefficient = 0.68; P renal function. Maintenance of the medullary oxygen bioavailability in low blood flow states may reflect the autoregulation particular to this region of the kidney. The ability to non-invasively measure all three parameters of kidney function in a single MRI examination and to evaluate the relationships between these functional parameters is potentially useful for evaluating the state of the human kidneys in situ in future studies.

  3. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent

    International Nuclear Information System (INIS)

    Fink, Christian; Ley, Sebastian; Puderbach, Michael; Plathow, Christian; Kauczor, Hans-Ulrich; Bock, Michael

    2004-01-01

    The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 ; voxel size: 1.3 x 2.5 x 4.0 mm 3 ; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 ; voxel size: 0.8 x 1.0 x 1.6 mm 3 ) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21±8 vs. 13±3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer. (orig.)

  4. Is seroprevalence of hepatitis B and C among blood donors changing in Northern Pakistan?

    International Nuclear Information System (INIS)

    Butt, T.; But, B.

    2017-01-01

    Objective: To determine seroprevalence of hepatitis B and C among blood donors in 2009 and comparing with the seroprevalence in 2014. Study Design: Cross sectional study with retrospective data collection. Place and Duration of Study: Foundation University Medical College and Fauji Foundation Hospital, Rawalpindi. Data in 2009 and in 2014 were collected. Material and Methods: The blood samples collected from individuals from Province of Khyber Pakhtunkhawa, Azad Kashmir and Northern Punjab including Rawalpindi-Islamabad and comprised 3776 (in the year 2009) and 6740 (in the year 2014) adults ranging from 18 to 60 years who reported to Fauji Foundation Hospital, Rawalpindi voluntarily or as a compulsion to donate blood for their patients. Results: During 2009, there were 71 (1.88 percent) and 113 (2.99 percent) donors positive for hepatitis B surface antigen (HBsAg) and anti hepatitis C virus (Anti HCV) respectively out of a total of 3776 donors whereas during 2014 there were 106 (1.57 percent) and 174 (2.58 percent) donors positive for HBsAg and anti HCV respectively out of a total donors of 6740. There was no statistical significant difference between the year (2009 and 2014) and seroprevalence of HBsAg (p=0.239) and HCV positive donors (p=0.215). Conclusion: There is no significant change in seroprevalence of hepatitis B and C among blood donors during 2014 as compared to 2009 in Northern Pakistan. (author)

  5. Hepatitis B core antigen antibody as an indicator of a low grade carrier state for hepatitis B virus in a Saudi Arabian blood donor population.

    Science.gov (United States)

    Bernvil, S S; Andrews, V; Kuhns, M C; McNamara, A L

    1997-03-01

    Blood donor screening for anti-hepatitis B core antigen (anti-HBc) was introduced as a surrogate marker of non-A, non-B hepatitis prior to the availability of a specific test for hepatitis C. In areas endemic for hepatitis B virus (HBV), such as Saudi Arabia, earlier studies indicated that up to 30% of blood donors might disqualify if screened for anti-HBc. The issue was readdressed in a study of 6035 consecutive first-time Saudi national blood donors in an attempt to identify a subgroup of anti-HBc positive donors who might be at high risk of being low grade carriers of HBV. An isolated anti-HBc of high titer in a donor with a low or absent anti-hepatitis B surface antigen (anti-HBsAg) was taken as an indicator of increased risk of a low grade carrier state. Using this algorithm, an additional 125 (2%) donors would disqualify. HBsAg immune complex assays and polymerase chain reaction of donor samples with an isolated anti-HBc identified two donors with immune complexes and two donors with HBV DNA. All four donor samples expressed over 90% neutralization in the anti-HBc supplementary testing, indicating high titer anti-HBc. These findings seem to support the suggested policy of donor exclusion based on the anti-HBc and anti-HBsAg serology as a means to eliminate low grade carriers of HBV in endemic areas without jeopardizing the blood supply.

  6. Regional cerebral perfusion in cardiovascular reflex syncope

    International Nuclear Information System (INIS)

    Toeyry, J.P.; Kuikka, J.T.; Laensimies, E.A.

    1997-01-01

    Little is known about the regional cerebral perfusion in subjects with presyncope or syncope, and the impact that autonomic nervous dysfunction has on it. Seven subjects with cardiovascular vasodepressor reflex syncope were studied. A baseline test was performed with the patients standing in the 70 upright position, while the passive head-up tilt table test with and without isoprenaline infusion was employed for provocation. Regional cerebral perfusion was assessed by means of single-photon emission tomography with technetium-99m labelled V-oxo-1,2-N,N 1 -ethylenedylbis-l-cysteine diethylester (baseline, and during blood pressure decline in the provocation test) and the autonomic nervous function by means of spectral analysis of heart rate variability (baseline, and before blood pressure decline in the provocation test). Every subject showed an abrupt decline in blood pressure in the provocation test (five with presyncope and two with syncope). The systolic and diastolic blood pressures decreased significantly (P<0.001) between the baseline and the provocation study time points (radiopharmaceutical injection and lowest systolic blood pressure). Mean cerebral perfusion as average count densities decreased upon provocation as compared with baseline (190±63 vs 307±90 counts/voxel, respectively, P=0.013). Hypoperfusion was most pronounced in the frontal lobe. These results suggest that cerebral perfusion decreases markedly during presyncope or syncope with systemic blood pressure decline in subjects with cardiovascular vasodepressor syncope. Furthermore, the autonomic nervous function remains unchanged before the systemic blood pressure decline. (orig.). With 3 figs., 2 tabs

  7. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo

    2010-01-01

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years ±10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07±0.62 ml min -1 g -1 , whereas stress MBF was 3.15±1.93 ml min -1 g -1 and the MPR was 3.33±1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, β=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, β=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  8. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo [Mie Univ., Graduate School of Medicine, Tsu, Mie (Japan)

    2010-11-15

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years {+-}10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07{+-}0.62 ml min{sup -1} g{sup -1}, whereas stress MBF was 3.15{+-}1.93 ml min{sup -1} g{sup -1} and the MPR was 3.33{+-}1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, {beta}=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, {beta}=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  9. Intrahemispheric Perfusion in Chronic Stroke-Induced Aphasia

    Directory of Open Access Journals (Sweden)

    Cynthia K. Thompson

    2017-01-01

    Full Text Available Stroke-induced alterations in cerebral blood flow (perfusion may contribute to functional language impairments and recovery in chronic aphasia. Using MRI, we examined perfusion in the right and left hemispheres of 35 aphasic and 16 healthy control participants. Across 76 regions (38 per hemisphere, no significant between-subjects differences were found in the left, whereas blood flow in the right was increased in the aphasic compared to the control participants. Region-of-interest (ROI analyses showed a varied pattern of hypo- and hyperperfused regions across hemispheres in the aphasic participants; however, there were no significant correlations between perfusion values and language abilities in these regions. These patterns may reflect autoregulatory changes in blood flow following stroke and/or increases in general cognitive effort, rather than maladaptive language processing. We also examined blood flow in perilesional tissue, finding the greatest hypoperfusion close to the lesion (within 0–6 mm, with greater hypoperfusion in this region compared to more distal regions. In addition, hypoperfusion in this region was significantly correlated with language impairment. These findings underscore the need to consider cerebral perfusion as a factor contributing to language deficits in chronic aphasia as well as recovery of language function.

  10. Contrast-enhanced ultrasound evaluation of hepatic microvascular changes in liver diseases.

    Science.gov (United States)

    Ridolfi, Francesco; Abbattista, Teresa; Busilacchi, Paolo; Brunelli, Eugenio

    2012-10-07

    To assess if software assisted-contrast-enhanced ultrasonography (CEUS) provides reproducible perfusion parameters of hepatic parenchyma in patients affected by chronic liver disease. Forty patients with chronic viral liver disease, with (n = 20) or without (n = 20) cirrhosis, and 10 healthy subjects underwent CEUS and video recordings of each examination were then analysed with Esaote's Qontrast software. CEUS dedicated software Qontrast was used to determine peak (the maximum signal intensity), time to peak (TTP), region of blood value (RBV) proportional to the area under the time-intensity curve, mean transit time (MTT) measured in seconds and region of blood flow (RBF). Qontrast-assisted CEUS parameters displayed high inter-observer reproducibility (κ coefficients of 0.87 for MTT and 0.90 TTP). When the region of interest included a main hepatic vein, Qontrast-calculated TTP was significantly shorter in cirrhotic patients (vs non-cirrhotics and healthy subjects) (71.0 ± 11.3 s vs. 82.4 ± 15.6 s, 86.3 ± 20.3 s, P < 0.05). MTTs in the patients with liver cirrhosis were significantly shorter than those of controls (111.9 ± 22.0 s vs. 139.4 ± 39.8 s, P < 0.05), but there was no significant difference between the cirrhotic and non-cirrhotic groups (111.9 ± 22.0 s vs. 110.3 ± 14.6 s). Peak enhancement in the patients with liver cirrhosis was also higher than that observed in controls (23.9 ± 5.9 vs. 18.9 ± 7.1, P = 0.05). There were no significant intergroup differences in the RBVs and RBFs. Qontrast-assisted CEUS revealed reproducible differences in liver perfusion parameters during the development of hepatic fibrogenesis.

  11. Characterizing potential heart agents with an isolated perfused heart system

    International Nuclear Information System (INIS)

    Pendleton, D.B.; Sands, H.; Gallagher, B.M.; Camin, L.L.

    1984-01-01

    The authors have used an isolated perfused heart system for characterizing potential myocardial perfusion radiopharamaceuticals. Rabbit or guinea pig (GP) hearts are removed and perfused through the aorta with a blood-free buffer. Heart rate and ventricular pressure are monitored as indices of viability. Tc-99m-MAA is 96-100% retained in these hearts, and Tc-99m human serum albumin shows less than 5% extraction. Tl-201 is 30-40% extracted. It is known that in-vivo, Tc-99m(dmpe)/sub 2/Cl/sub 2//sup +/ is taken up by rabbit heart but not by GP or human heart. Analogous results are obtained with the isolated perfused heart model, where the complex is extracted well by the isolated rabbit heart (24%) but not by the GP heart (<5%). Values are unchanged if human, rabbit or GP blood is mixed and co-injected with the complex. Tc-99m)dmpe)/sub 3//sup +/ is also taken up by rabbit but not by GP hearts in-vivo. However, isolated perfused hearts of both species extract this complex well (45-52%). Heart uptake is diminished to <7% if the complex is pre-equilibrated with human blood. GP blood produces a moderate inhibition (in GP hearts only) and rabbit blood has no effect. This suggests that a human or GP blood factor may have a significant effect on heart uptake of this complex. Tc-99m(CN-t-butyl)/sub 6//sup +/ is taken up well by both rabbit and GP hearts in-vivo, and is extracted 100% by both isolated perfused hearts. Heart retention remains high (73-75%) in the presence of human blood

  12. Changes of very low-density lipoprotein concentration in hepatic blood from cows with fasting-induced hepatic lipidosis.

    Science.gov (United States)

    Oikawa, Shin; Mizunuma, Yuko; Iwasaki, Yukari; Tharwat, Mohamed

    2010-10-01

    The purpose of this study was to evaluate changes of very low-density lipoprotein (VLDL) components in hepatic blood (HB) from 5 nonlactating nonpregnant cows fasted from days 0 to 3 and subsequently refed to day 10 and, in addition, to assess those of other lipoproteins. Increased phospholipid concentrations in each lipoprotein after the start of fasting suggested their availability for the surface lipids of lipoproteins. Although the VLDL-triglyceride (TG) concentration in HB from all cows increased on day 1, the value on day 4 became similar to that on day 0. However, the concentration on day 10 was significantly increased. In all cows, the decreased ratio of the VLDL-TG concentration in HB to the non-esterified fatty acids (NEFA) concentration in portal blood (PB) on day 4 appeared to reflect relatively decreased secretion of TG as VLDL by NEFA excessively mobilized to the liver via PB. The markedly increased ratio on day 10 was considered to contribute to the improvement of hepatic lipidosis.

  13. Seroprevalence and Incidence of hepatitis E in blood donors in Upper Austria.

    Directory of Open Access Journals (Sweden)

    Carina Fischer

    Full Text Available In recent years various studies showed, that hepatitis E virus (HEV is a growing public health problem in many developed countries. Therefore, HEV infections might bear a transmission risk by blood transfusions. The clinical relevance still requires further investigations. The aim of this study was to provide an overview of acute HEV infections in Upper Austrian blood donors as well as a risk estimation of this transfusion-related infection.A total of 58,915 blood donors were tested for HEV RNA using a commercial HEV RT-PCR Kit. 7 of these donors (0.01% were PCR-positive with normal laboratory parameters in absence of clinical signs of hepatitis. Viral load determined by quantitative real-time PCR showed a HEV nucleic acid concentration of 2,217 293,635 IU/ml. At follow-up testing (2-11 weeks after donation all blood donors had negative HEV RNA results. Additionally, genotyping was performed by amplification and sequencing of the ORF1 or ORF2 region of the HEV genome. All HEV RNA positive donor samples revealed a genotype 3 isolate. For the antibody screening, anti-HEV IgM and IgG were detected by ELISA. Follow up serological testing revealed that no donor was seropositive for HEV IgM or IgG antibodies at time of donation. Moreover, we verified the prevalence of anti-HEV IgG in 1,203 of the HEV RNA negative tested blood donors. Overall 13.55% showed positive results for anti-HEV IgG.In the presented study, we investigated HEV infections in blood donations of Upper Austria over 1 year. We concluded that 1 out of 8,416 blood donations is HEV RNA positive. Seroprevalence of anti HEV IgG results in an age-related increase of 13.55%. Therefore, based on this data, we recommend HEV-PCR screening to prevent transmission of hepatitis E virus by transfusion.

  14. Standardized perfusion value of the esophageal carcinoma and its correlation with quantitative CT perfusion parameter values

    Energy Technology Data Exchange (ETDEWEB)

    Djuric-Stefanovic, A., E-mail: avstefan@eunet.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Saranovic, Dj., E-mail: crvzve4@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Sobic-Saranovic, D., E-mail: dsobic2@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia); Masulovic, D., E-mail: draganmasulovic@yahoo.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Artiko, V., E-mail: veraart@beotel.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia)

    2015-03-15

    Purpose: Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. Methods: Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient (r{sub S}). Results: Median SPV of the esophageal carcinoma (7.1; range: 2.8–13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4–2.4), (Z = −5.511, p < 0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF (r{sub S} = 0.484, p = 0.002), BV (r{sub S} = 0.637, p < 0.001) and PS (r{sub S} = 0.432, p = 0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF (r{sub S} = 0.573, p < 0.001), BV (r{sub S} = 0.849, p < 0.001) and PS (r{sub S} = 0.761, p < 0.001). Conclusions: We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy

  15. TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps

    Energy Technology Data Exchange (ETDEWEB)

    Mendrik, Adrienne M; Van Ginneken, Bram; Viergever, Max A [Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Vonken, Evert-jan; De Jong, Hugo W; Riordan, Alan; Van Seeters, Tom; Smit, Ewoud J; Prokop, Mathias, E-mail: a.m.mendrik@gmail.com [Radiology Department, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2011-07-07

    Cerebral computed tomography perfusion (CTP) scans are acquired to detect areas of abnormal perfusion in patients with cerebrovascular diseases. These 4D CTP scans consist of multiple sequential 3D CT scans over time. Therefore, to reduce radiation exposure to the patient, the amount of x-ray radiation that can be used per sequential scan is limited, which results in a high level of noise. To detect areas of abnormal perfusion, perfusion parameters are derived from the CTP data, such as the cerebral blood flow (CBF). Algorithms to determine perfusion parameters, especially singular value decomposition, are very sensitive to noise. Therefore, noise reduction is an important preprocessing step for CTP analysis. In this paper, we propose a time-intensity profile similarity (TIPS) bilateral filter to reduce noise in 4D CTP scans, while preserving the time-intensity profiles (fourth dimension) that are essential for determining the perfusion parameters. The proposed TIPS bilateral filter is compared to standard Gaussian filtering, and 4D and 3D (applied separately to each sequential scan) bilateral filtering on both phantom and patient data. Results on the phantom data show that the TIPS bilateral filter is best able to approach the ground truth (noise-free phantom), compared to the other filtering methods (lowest root mean square error). An observer study is performed using CBF maps derived from fifteen CTP scans of acute stroke patients filtered with standard Gaussian, 3D, 4D and TIPS bilateral filtering. These CBF maps were blindly presented to two observers that indicated which map they preferred for (1) gray/white matter differentiation, (2) detectability of infarcted area and (3) overall image quality. Based on these results, the TIPS bilateral filter ranked best and its CBF maps were scored to have the best overall image quality in 100% of the cases by both observers. Furthermore, quantitative CBF and cerebral blood volume values in both the phantom and the

  16. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    Science.gov (United States)

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients

    Energy Technology Data Exchange (ETDEWEB)

    Kaemena, Andreas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)], E-mail: andreas.kaemena@charite.de; Streitparth, Florian; Grieser, Christian; Lehmkuhl, Lukas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany); Jamil, Basil [Department of Radiotherapy, Charite-Medical University Berlin, Schumannstr. 20/21, D-10117 Berlin (Germany); Wojtal, Katarzyna; Ricke, Jens; Pech, Maciej [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)

    2007-10-15

    Purpose: To assess the influence of different temporal sampling rates on the accuracy of the results from cerebral perfusion CTs in patients with an acute ischemic stroke. Material and methods: Thirty consecutive patients with acute stroke symptoms received a dynamic perfusion CT (LightSpeed 16, GE). Forty millilitres of iomeprol (Imeron 400) were administered at an injection rate of 4 ml/s. After a scan delay of 7 s, two adjacent 10 mm slices at 80 kV and 190 mA were acquired in a cine mode technique with a cine duration of 49 s. Parametric maps for the blood flow (BF), blood volume (BV) and mean transit time (MTT) were calculated for temporal sampling intervals of 0.5, 1, 2, 3 and 4 s using GE's Perfusion 3 software package. In addition to the quantitative ROI data analysis, a visual perfusion map analysis was performed. Results: The perfusion analysis proved to be technically feasible with all patients. The calculated perfusion values revealed significant differences with regard to the BF, BV and MTT, depending on the employed temporal resolution. The perfusion contrast between ischemic lesions and healthy brain tissue decreased continuously at the lower temporal resolutions. The visual analysis revealed that ischemic lesions were best depicted with sampling intervals of 0.5 and 1 s. Conclusion: We recommend a temporal scan resolution of two images per second for the best detection and depiction of ischemic areas.

  18. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  19. Spatio-temporal cerebral blood flow perfusion patterns in cortical spreading depression

    Science.gov (United States)

    Verisokin, Andrey Yu.; Verveyko, Darya V.; Postnov, Dmitry E.

    2017-04-01

    Cortical spreading depression (CSD) is an example of one of the most common abnormalities in biophysical brain functioning. Despite the fact that there are many mathematical models describing the cortical spreading depression (CSD), most of them do not take into consideration the role of redistribution of cerebral blood flow (CBF), that results in the formation of spatio-temporal patterns. The paper presents a mathematical model, which successfully explains the CBD role in the CSD process. Numerical study of this model has revealed the formation of stationary dissipative structures, visually analogous to Turing structures. However, the mechanism of their formation is not diffusion. We show these structures occur due to another type of spatial coupling, that is related to tissue perfusion rate. The proposed model predicts that at similar state of neurons the distribution of blood flow and oxygenation may by different. Currently, this effect is not taken into account when the Blood oxygen-level dependent (BOLD) contrast imaging used in functional magnetic resonance imaging (fMRI). Thus, the diagnosis on the BOLD signal can be ambiguous. We believe that our results can be used in the future for a more correct interpretation of the data obtained with fMRI, NIRS and other similar methods for research of the brain activity.

  20. Corrections of arterial input function for dynamic H215O PET to assess perfusion of pelvic tumours: arterial blood sampling versus image extraction

    International Nuclear Information System (INIS)

    Luedemann, L; Sreenivasa, G; Michel, R; Rosner, C; Plotkin, M; Felix, R; Wust, P; Amthauer, H

    2006-01-01

    Assessment of perfusion with 15 O-labelled water (H 2 15 O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF

  1. Metabolism of 1-[14C]nitropyrene in isolated perfused rat livers

    International Nuclear Information System (INIS)

    Bond, J.A.; Medinsky, M.A.; Dutcher, J.S.

    1984-01-01

    1-Nitropyrene (1-NP), a constituent of diesel exhaust, is carcinogenic to rats and is a bacterial and mammalian mutagen. Biliary and fecal excretion of 1-NP metabolites are the major routes of excretion in rats, suggesting that hepatic metabolism plays a dominant role in determining the biological fate of 1-NP. The purpose of this investigation was to quantitate 1-[14C]NP metabolites formed in isolated perfused rat livers and excreted in bile from rats. Perfused rat livers displayed a capacity for oxidation, reduction, acetylation, and conjugation of 1-NP (or its metabolites). Reduction of 1-NP followed by N-acetylation was the major metabolic pathway observed in the perfused livers. Acetylaminopyrene (AAP) was the major metabolite detected, with total quantities (150 nmol) accounting for about 60% of the total 1-[14C]NP dose (258 nmol) added to the perfusate. Considerably smaller quantities of aminopyrene and hydroxynitropyrenes were also detected. Livers perfused with 1-[14C]NP excreted about 36 nmol equivalents of 1-[14C]NP (12% of the total 1-NP dose) in bile after 60 min. Some of the biliary metabolites were tentatively identified as metabolites of the mercapturic acid pathway. The spectrum of biliary metabolites was qualitatively identical to that seen in bile from intact rats. Quantities of 14C covalently bound to hepatic macromolecules from perfused livers were 0.4 nmol 1-NP eq/g liver. The data from this study indicate that the liver may be an important site for metabolism of 1-NP

  2. Safety of blood supply in the Caribbean countries: role of screening blood donors for markers of hepatitis B and C viruses.

    Science.gov (United States)

    Cruz, Jose R; Pérez-Rosales, Maria Dolores; Zicker, Fabio; Schmunis, Gabriel A

    2005-12-01

    Blood transfusions carry risks of untoward reactions, including the transmission of infections, such as hepatitis B and C. Proper blood donor recruitment and selection, and adequate laboratory screening for infectious markers diminish the risk of transfusion-transmitted infections. To estimate the potential risk of acquiring transfusion-transmitted infections by hepatitis B or hepatitis C in 24 Caribbean countries during the period of 1996 to 2003. Official national reports for 1996, 2000-2003 of the yearly number of blood donors, screening coverage, and prevalence of serological markers for infectious diseases were used to estimate the risk of patients receiving an HBV- or HCV-positive unit of blood, and of developing an infection after receiving a positive unit. Estimates of number of infections transmitted through transfusion and number of infections prevented by screening of blood were also obtained. During the period analyzed, HBV screening coverage among blood donors was 100% in all countries with the exception of Grenada (0% in 1996) and Saint Lucia (99.5% in 2002). For HCV, only 10 countries reported universal screening in 1996, while 15 did in 2003. The number of countries that did not screen any units for HCV decreased from 11 in 1996 to five in 2003. In general, high prevalence rates of HBV (10-75 per 1000 donors) and HCV (7-19.3 per 1000 donors) markers were found in the majority of countries. We estimated that 235 infections by HCV (1:12471 donations) and two infections by HBV (1:1465373) were transmitted through transfusion because of lack of screening. On the other hand, screening of blood for transfusion prevented 21 005 HCV and 22 100 HBV infections. Blood donor recruitment and coverage of screening for transfusion-transmitted infections, especially HCV, must be improved in the Caribbean countries.

  3. Hepatic (Liver) Function Panel

    Science.gov (United States)

    ... Educators Search English Español Blood Test: Hepatic (Liver) Function Panel KidsHealth / For Parents / Blood Test: Hepatic (Liver) ... kidneys ) is working. What Is a Hepatic (Liver) Function Panel? A liver function panel is a blood ...

  4. Hyperventilation, cerebral perfusion, and syncope

    DEFF Research Database (Denmark)

    Immink, R V; Pott, F C; Secher, N H

    2014-01-01

    dioxide (PaCO2) and oxygen (PaO2) partial pressures so that hypercapnia/hypoxia increases and hypocapnia/hyperoxia reduces global cerebral blood flow. Cerebral hypoperfusion and TLOC have been associated with hypocapnia related to HV. Notwithstanding pronounced cerebrovascular effects of PaCO2...... the contribution of a low PaCO2 to the early postural reduction in middle cerebral artery blood velocity is transient. HV together with postural stress does not reduce cerebral perfusion to such an extent that TLOC develops. However when HV is combined with cardiovascular stressors like cold immersion or reduced...... cardiac output brain perfusion becomes jeopardized. Whether, in patients with cardiovascular disease and/or defect, cerebral blood flow cerebral control HV-induced hypocapnia elicits cerebral hypoperfusion, leading to TLOC, remains to be established....

  5. Temporal and spectral properties of esophageal mucosal blood perfusion: a comparison between normal subjects and nutcracker esophagus patients.

    Science.gov (United States)

    Zifan, A; Jiang, Y; Mittal, R K

    2017-02-01

    The mechanism of esophageal pain in patients with nutcracker esophagus (NE) and other esophageal motor disorders is not known. Our recent study shows that baseline esophageal mucosal perfusion, measured by laser Doppler perfusion monitoring, is lower in NE patients compared to controls. The goal of our current study was to perform a more detailed analysis of esophageal mucosal blood perfusion (EMBP) waveform of NE patients and controls to determine the optimal EMBP biomarkers that combined with suitable statistical learning models produce robust discrimination between the two groups. Laser Doppler recordings of 10 normal subjects (mean age 43 ± 15 years, 8 males) and 10 patients (mean age 47 ± 5.5 years., 8 males) with NE were analyzed. Time and frequency domain features were extracted from the first twenty-minute recordings of the EMBP waveforms, statistically ranked according to four independent evaluation criterions, and analyzed using two statistical learning models, namely, logistic regression (LR) and support vector machines (SVM). The top three ranked predictors between the two groups were the 0.5 and 0.75 perfusion quantile values followed by the surface of the EMBP power spectrum in the frequency domain. ROC curve ranking produced a cross-validated AUC (area under the curve) of 0.93 for SVM and 0.90 for LR. We show that as a group NE patients have lower perfusion values compared to controls, however, there is an overlap between the two groups, suggesting that not all NE patients suffer from low mucosal perfusion levels. © 2016 John Wiley & Sons Ltd.

  6. Human immunodeficiency virus (HIV) seropositivity and hepatitis B surface antigenemia (HBSAG) among blood donors in Benin city, Edo state, Nigeria.

    Science.gov (United States)

    Umolu, Patience Idia; Okoror, Lawrence Ehis; Orhue, Philip

    2005-03-01

    Human Immunodeficiency Virus and Hepatitis B virus are blood borne pathogens that can be transmitted through blood transfusion and could pose a huge problem in areas where mechanisms of ensuring blood safety are suspect. This study became necessary in a population where most of the blood for transfusion is from commercial blood donors. A total of 130 donors comprising 120 commercial donors and 10 voluntary donors were tested for antibodies to human immunodeficiency virus and hepatitis B surface antigen in Benin city using Immunocomb HIV - 1 and 2 Biospot kit and Quimica Clinica Aplicada direct latex agglutination method respectively. Thirteen (10%) samples were HIV seropositive and 7(5.8%) were HBsAg positive. The age bracket 18 - 25years had the highest numbers of donors and also had the highest number of HBsAg positive cases (7.8%) while the age group 29 - 38years had highest number of HIV seropositive cases. High prevalence of HIV antibodies and Hepatitis B surface antigen was found among commercial blood donors. Appropriate and compulsory screening of blood donors using sensitive methods, must be ensured to prevent post transfusion hepatitis and HIV.

  7. Hepatitis G virus (HGV) infection in voluntary and commercial blood donors in India.

    Science.gov (United States)

    Kar, P; Bedi, P; Berry, N; Chakravorty, A; Gupta, R K; Saha, R; Das, B C

    2000-09-01

    The prevalence of hepatitis G virus (HGV) has been determined in commercial as well as voluntary blood donors from India by detecting viral RNA genome using reverse transcription polymerase chain reaction (RT-PCR) assay. 45 professional blood donors from private blood banks and 50 healthy controls who opted for voluntary blood donation were recruited for the study. Both the groups were also screened serologically for HBV and HCV infection. The prevalence of HGV in the general population in India was found to be 4% but significantly a higher frequency (46.6%; pcommercial blood donors.

  8. The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model

    Science.gov (United States)

    Lanctot, Anthony C; McCarter, Martin D; Roberts, Katherine M; Glueck, Deborah H; Dodd, Gerald D

    2017-01-01

    Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (Rβ2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use. PMID:27925468

  9. Combined functional CT/FDG-PET: demonstrates reduced hepatic phosphorylation of glucose in advanced colorectal cancer

    International Nuclear Information System (INIS)

    Miles, K.A.; Keith, C.J.; Griffiths, M.R.; Fuentes, M.; Bunce, I.

    2002-01-01

    Full text: This study describes a technique to quantify hepatic glucose phosphorylation using combined data from functional CT and FDG-PET and assesses the differences in phosphorylation between patients with either early or advanced colorectal cancer. Functional CT and FDG-PET were utilised to obtain measurements of perfusion and glucose uptake respectively within the livers of a series of 35 patients with colorectal cancer. Patients with PET evidence of extrahepatic tumour were considered to have advanced disease. The net influx constant (Ki) for FDG was determined from the liver SUV. CT measurements of hepatic perfusion were incorporated into FDG kinetic analysis to determine hepatic glucose phosphorylation fraction. SUV and Ki were significantly lower in the 12 patients with advanced disease (p=0.015 and p=0.013 respectively) whereas portal and total hepatic perfusion were increased (p=0.013 and p=0.008 respectively). Combining the PET and CT data yielded phosphorylation fractions of 1.14% and 0.74% for early and advanced disease respectively (p=0.002). Hepatic glucose phosphorylation can be determined by combining functional CT measurements of perfusion with PET measurements of FDG and is significantly reduced in patients with more advanced malignancy. Reduced hepatic glucose phosphorylation may be an important mechanism in the development of cancer cachexia. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  10. Combined functional CT/FDG-PET: demonstrates reduced hepatic phosphorylation of glucose in advanced colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Miles, K A [Southernex Imaging Group, QLD (Australia); Queensland University of Technology, QLD (Australia); Keith, C J [Southernex Imaging Group, QLD (Australia); Wesley Research Institute, QLD (Australia); Griffiths, M R [Queensland University of Technology, QLD (Australia); Fuentes, M [Southernex Imaging Group, QLD (Australia); Bunce, I [Wesley Research Institute, QLD (Australia)

    2002-07-01

    Full text: This study describes a technique to quantify hepatic glucose phosphorylation using combined data from functional CT and FDG-PET and assesses the differences in phosphorylation between patients with either early or advanced colorectal cancer. Functional CT and FDG-PET were utilised to obtain measurements of perfusion and glucose uptake respectively within the livers of a series of 35 patients with colorectal cancer. Patients with PET evidence of extrahepatic tumour were considered to have advanced disease. The net influx constant (Ki) for FDG was determined from the liver SUV. CT measurements of hepatic perfusion were incorporated into FDG kinetic analysis to determine hepatic glucose phosphorylation fraction. SUV and Ki were significantly lower in the 12 patients with advanced disease (p=0.015 and p=0.013 respectively) whereas portal and total hepatic perfusion were increased (p=0.013 and p=0.008 respectively). Combining the PET and CT data yielded phosphorylation fractions of 1.14% and 0.74% for early and advanced disease respectively (p=0.002). Hepatic glucose phosphorylation can be determined by combining functional CT measurements of perfusion with PET measurements of FDG and is significantly reduced in patients with more advanced malignancy. Reduced hepatic glucose phosphorylation may be an important mechanism in the development of cancer cachexia. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc.

  11. Albumin modulates S1P delivery from red blood cells in perfused microvessels: mechanism of the protein effect.

    Science.gov (United States)

    Adamson, R H; Clark, J F; Radeva, M; Kheirolomoom, A; Ferrara, K W; Curry, F E

    2014-04-01

    Removal of plasma proteins from perfusates increases vascular permeability. The common interpretation of the action of albumin is that it forms part of the permeability barrier by electrostatic binding to the endothelial glycocalyx. We tested the alternate hypothesis that removal of perfusate albumin in rat venular microvessels decreased the availability of sphingosine-1-phosphate (S1P), which is normally carried in plasma bound to albumin and lipoproteins and is required to maintain stable baseline endothelial barriers (Am J Physiol Heart Circ Physiol 303: H825-H834, 2012). Red blood cells (RBCs) are a primary source of S1P in the normal circulation. We compared apparent albumin permeability coefficients [solute permeability (Ps)] measured using perfusates containing albumin (10 mg/ml, control) and conditioned by 20-min exposure to rat RBCs with Ps when test perfusates were in RBC-conditioned protein-free Ringer solution. The control perfusate S1P concentration (439 ± 46 nM) was near the normal plasma value at 37 °C and established a stable baseline Ps (0.9 ± 0.4 × 10(-6) cm/s). Ringer solution perfusate contained 52 ± 8 nM S1P and increased Ps more than 10-fold (16.1 ± 3.9 × 10(-6) cm/s). Consistent with albumin-dependent transport of S1P from RBCs, S1P concentrations in RBC-conditioned solutions decreased as albumin concentration, hematocrit, and temperature decreased. Protein-free Ringer solution perfusates that used liposomes instead of RBCs as flow markers failed to maintain normal permeability, reproducing the "albumin effect" in these mammalian microvessels. We conclude that the albumin effect depends on the action of albumin to facilitate the release and transport of S1P from RBCs that normally provide a significant amount of S1P to the endothelium.

  12. Automatic Detection of Myocardial Boundaries in MR Cardio Perfusion Images

    NARCIS (Netherlands)

    Spreeuwers, Luuk; Breeuwer, Marcel

    2001-01-01

    Cardiovascular diseases often result in reduced blood perfusion of the myocardium (MC). Recent advances in MR allow fast recordingof contrast enhanced myocardial perfusion scans. For perfusion analysis the myocardial boundaries must be traced. Currently this is done manually. In this paper a method

  13. Towards robust deconvolution of low-dose perfusion CT: Sparse perfusion deconvolution using online dictionary learning

    Science.gov (United States)

    Fang, Ruogu; Chen, Tsuhan; Sanelli, Pina C.

    2014-01-01

    Computed tomography perfusion (CTP) is an important functional imaging modality in the evaluation of cerebrovascular diseases, particularly in acute stroke and vasospasm. However, the post-processed parametric maps of blood flow tend to be noisy, especially in low-dose CTP, due to the noisy contrast enhancement profile and the oscillatory nature of the results generated by the current computational methods. In this paper, we propose a robust sparse perfusion deconvolution method (SPD) to estimate cerebral blood flow in CTP performed at low radiation dose. We first build a dictionary from high-dose perfusion maps using online dictionary learning and then perform deconvolution-based hemodynamic parameters estimation on the low-dose CTP data. Our method is validated on clinical data of patients with normal and pathological CBF maps. The results show that we achieve superior performance than existing methods, and potentially improve the differentiation between normal and ischemic tissue in the brain. PMID:23542422

  14. Assessment of local changes of cerebral perfusion and blood concentration by ultrasound harmonic B-mode contrast measurement in piglet.

    NARCIS (Netherlands)

    Wijk, M.C. van; Klaessens, J.H.G.M.; Hopman, J.C.W.; Liem, K.D.; Thijssen, J.M.

    2003-01-01

    This study tested the hypothesis that changes in the blood concentration, and possibly in the perfusion, of different areas in the brain can be assessed by the use of ultrasound contrast agent (CA) and (linear) echo densitometry. The experiments were performed with piglets (n=3) under general

  15. [The effect of portal blood stasis on lung and renal injury induced by hepatic ischemia reperfusion in a rabbit model].

    Science.gov (United States)

    Wang, Ye; Yang, Jia-mei; Hou, Yuan-kai; Li, Dian-qi; Hu, Ming-hua; Liu, Peng

    2008-04-15

    To investigate the effect and mechanism of portal blood stasis on lung and renal injury induced by hepatic ischemia reperfusion. A rabbit hepatic ischemia reperfusion injury model was established by hepatic portal occlusion and in situ hypothermic irrigation for 30 min. Twenty-four New Zealand white rabbits were employed and randomly divided into 3 groups equally by different dosage of portal blood stasis removal: group A5 (5 ml blood removal), group A10 (10 ml blood removal),and group B (no blood removal). Eight rabbits were served as controls with no hepatic portal occlusion and hypothermic irrigation. After reperfusion 4 h serum endotoxin content, tumor necrosis factor-alpha (TNF-alpha), urea nitrogen (BUN), and creatinine (Cr) were examined respectively, meantime lung and kidney tissues were sampled to determine the content of malondialdehyde (MDA), superoxide dismutase (SOD), the pathology, and wet to dry weight ratio, broncho-alveolar lavage fluid protein content in lung tissues. Removing portal blood stasis ameliorated lung and renal injury as shown by decreasing the level of serum endotoxin, TNF-alpha, BUN, Cr, wet to dry weight ratio, broncho-alveolar lavage fluid protein content, MDA, SOD. TNF-alpha, Cr, broncho-alveolar lavage fluid protein content in lung tissues and MDA in kidney tissue in group A5 were significantly reduced compared with those in group B (P portal blood stasis before the resume of splanchnic circulation may ameliorate the lung and renal injury induced by hepatic ischemia reperfusion. The possible mechanism may be that portal blood stasis removal reduces endotoxin absorption, and further decreases production of serum TNF-alpha.

  16. Surface antigen-negative hepatitis B virus infection in Dutch blood donors

    NARCIS (Netherlands)

    Lieshout-Krikke, R. W.; Molenaar-de Backer, M. W. A.; van Swieten, P.; Zaaijer, H. L.

    2014-01-01

    Hepatitis B virus (HBV) surface antigen (HBsAg) is a reliable marker for HBV infection, but HBsAg-negative forms of HBV infection occur. The introduction of HBV DNA screening of Dutch blood donors, which were not preselected for absence of HBV core antibodies, enabled the characterization of

  17. Routine screening of blood donations at Qingdao central blood bank, China, for hepatitis B virus (HBV) DNA with a real-time, multiplex nucleic acid test for HBV, hepatitis C virus, and human immunodeficiency virus Types 1 and 2.

    Science.gov (United States)

    Yang, Zhongsi; Xu, Lei; Liu, Li; Feng, Qiuxia; Zhang, Longmu; Ma, Weijuan; Saldanha, John; Wang, Mingmin; Zhao, Lin

    2013-10-01

    The Roche cobas TaqScreen MPX test was used to evaluate the rate of hepatitis B surface antigen (HBsAg)-negative donations that were hepatitis B virus (HBV) DNA reactive from June 2010 to January 2011 in Qingdao, China. HBsAg-negative samples from 65,800 voluntary blood donors were tested with the cobas TaqScreen MPX test in pools of 6 on the Roche cobas s 201 blood screening platform. Samples positive for HBV DNA and negative for HBsAg were quantitated with the Roche COBAS AmpliPrep/COBAS TaqMan HBV test. In addition, serologic tests for HBsAg, hepatitis B surface antibody, anti-hepatitis B core antigen (anti-HBc), anti-hepatitis B e antigen (anti-HBe), and hepatitis B e antigen (HBe) were done using the Roche electrochemiluminescence immunoassay. A total of 80 nucleic acid amplification technology (NAT) test-reactive pools were identified and 59 pools (74%) resolved to a reactive sample. All samples were HBV DNA reactive and the viral load in each sample was quantitated. The viral loads of the samples ranged from less than 20 to 34,600 IU/mL; 13 samples (22%) had viral loads of more than 20 IU/mL, 27 samples (45.8%) had viral loads of less than 20 IU/mL, and 19 samples (32.2%) had undetectable viral loads. Of the 59 NAT-reactive samples, 40 (67.8%) were anti-HBc positive. Fifteen of the 59 samples could not be confirmed as NAT reactive either by an alternative NAT test or by serology. The HBV NAT yield in blood donors in Qingdao is 0.06% (38/65,800). This study confirmed the value of NAT for interdicting HBV-positive donations and preventing transfusion-transmitted HBV infections. © 2013 American Association of Blood Banks.

  18. Development of a new extracorporeal whole-liver perfusion system.

    Science.gov (United States)

    Naruse, Katsutoshi; Sakai, Yasuyuki; Guo, Lei; Natori, Takeshi; Shindoh, Junichi; Karasawa, Yasuaki; Iida, Yuhki; Kojima, Kentaro; Michishita, Kazuya; Makuuchi, Masatoshi

    2003-01-01

    We have developed a new extracorporeal whole-liver accommodation device in which a whole swine liver is placed in a physiological state by modeling the intraabdominal arrangement in the pig body, with the liver supported by a special inferior vena cava tube. Furthermore, we employed a diaphragm-type artificial heart in our system to produce pulsatile blood flow through the hepatic artery, which is considered to be indispensable to dilate peripheral vessels and supply oxygenated whole blood to the peripheral liver tissue. Beneficial effects were demonstrated in visual findings and bile juice secretion. The color of the liver surface in our system remained bright red, indicating that the liver vessels were well drained and free from congestion, and bile juice secretion was maintained at more than 10 ml/h throughout the perfusion period. Our system exhibited excellent ammonia removal and urea nitrogen synthesis, and serum aspartate aminotransferase levels showed no increase, indicating the absence of hepatocyte destruction. Histological findings showed that the liver could expand appropriately and was free from compression caused by its own weight. In conclusion, our original liver accommodation device enabled appropriate expansion of the whole liver and supplied adequate oxygenated blood to peripheral areas by means of a pulsatile pump.

  19. Comparison of Acupuncture Effect on Blood Perfusion between Needling Nonacupoint on Meridian and Needling Nonacupoint off Meridian

    Directory of Open Access Journals (Sweden)

    Wei-Bo Zhang

    2013-01-01

    Full Text Available To verify the ancient theory of rather missing the acupoint than missing the meridian, acupuncture at nonacupoint on meridian and acupuncture at nonacupoint off meridian were performed, respectively. The blood perfusion (BP on the calf around bladder meridian area was measured with a laser Doppler perfusion imager before, during, and after acupuncture. The whole scanning field was divided into seven subareas, and mean BP on each area was calculated. The ratio of mean BP between a subarea and a reference subarea was gotten, and then the change rate was calculated as ratio change rate (RCR. The results showed that RCR on bladder meridian area and around Chengshan (BL57 during or after acupuncture at nonacupoint on meridian was significantly higher than that at nonacupoint off meridian, which supports the ancient theory. Such differences may be attributable to some factors that can facilitate the signals transmission and produce a better acupuncture effect, such as richer nerve terminals, blood vessels, and mast cells which can produce stronger signals on the acupoints and the low hydraulic resistance channel along meridians which plays a role of signal transmitting channel to get a better effect of acupuncture.

  20. Feature Hepatitis: Hepatitis Symptoms, Diagnosis, Treatment & Prevention

    Science.gov (United States)

    ... Navigation Bar Home Current Issue Past Issues Feature Hepatitis Hepatitis: Symptoms, Diagnosis, Treatment & Prevention Past Issues / Spring 2009 ... No appetite Fever Headaches Diagnosis To check for hepatitis viruses, your doctor will test your blood. You ...

  1. Seroprevalence and risk factors of Hepatitis B and Hepatitis C ...

    African Journals Online (AJOL)

    Undertaking blood transfusion, tattooing and sharing of needles were associated with hepatitis C infection (P=0.001). HBV was not associated with any of the risk factors (P>0.05). Conclusion: Our findings suggest a high prevalence of hepatitis B and hepatitis C among pregnant women; blood transfusion, tattooing and ...

  2. Seroprevalence of hepatitis E virus among blood donors in Qatar (2013-2016)

    OpenAIRE

    Nasrallah, Gheyath K.; Al Absi, Enas S.; Ghandour, Rula; Ali, Nadima H.; Taleb, Sara; Hedaya, Laila; Ali, Fatima; Huwaidy, Mariam; Husseini, Abdullatif

    2017-01-01

    BACKGROUND Hepatitis E virus (HEV) is an RNA virus transmitted mainly through zoonotic transmission or fecal–oral route. More than 80% of Qatar's population are expatriates, including many coming from hyperendemic countries; thus, it is important to estimate the seroprevalence and to compare between different nationalities. The results can be useful in alerting blood banks to the importance of HEV screening. STUDY DESIGN AND METHODS Samples from 5854 blood donations provided by Ham...

  3. Influence of ocular perfusion pressure fluctuation on glaucoma

    Directory of Open Access Journals (Sweden)

    Min-Zi Ren

    2015-12-01

    Full Text Available AIM:To investigate the influence of ocular perfusion pressure fluctuation on glaucoma. METHODS:Forty patients with primary open angle glaucoma from January 2013 to June 2015 in our hospital were used as observation group and 40 families were used as control group. Circadian fluctuation of intraocular pressure, blood pressure and ocular perfusion pressure in 24h were determined to obtain systolic ocular perfusion pressure(SOPP, diastolic ocular perfusion pressure(DOPPand mean ocular perfusion pressure(MOPP. Pearson linear correlation was used to analyze the correlation of circadian MOPP fluctuation with cup-disc ratio, mean defect(MDand the picture standard deviation(PSD. RESULTS:The fluctuation of MOPP, SOPP and DOPP of observation group were significantly higher than those of control group(Pr=-0.389, 95%CI:-0.612~-0.082; P=0.011, was positively correlated with PSD(r=0.512, 95%CI:0.139 ~0.782; P=0.008; no correlation was found between it and the vertical cup-disc ratio(r=0.115, 95%CI:0.056~0.369; P=0.355. CONCLUSION:Ocular perfusion pressure fluctuations in patients with primary open angle glaucoma may reflect the severity of the disease and may make the situation aggravating. Therefore through perfusion pressure monitor in 24h may help us understand the ocular blood flow and the development of primary open-angle glaucoma.

  4. Importance of radioimmunoassays (HBsAg, HBsAb and HBcAb) for reducing the risk of hepatitis B transfer by blood

    International Nuclear Information System (INIS)

    Novak, J.; Kselikova, M.

    1979-01-01

    The principles are reported of the radioimmunoanalytical assay of the hepatitis B surface antigen, antibodies against this antigen which constitute immunologically indirect evidence, and antibodies against the nucleus of Dane's particles, which is circumstantial immunological evidence. The results obtained by radioimmunoassay are compared with those obtained by enzyme immunoassay. The results are presented obtained during the investigations of a total of 79 individuals, blood donors, health workers, and haemodialytic patients. In the whole group the hepatitis B surface antigen was proved by radioimmunoassay in 54%, by enzyme immunoassay in 47%; the antibody against the hepatitis B surface antigen in 19%; the antibody against the nucleus of the hepatitis B virus showed the largest proportion 75%. In 6.3% radioimmunoassay showed symptoms all three of hepatitis B, i.e., the surface antigen, the antibody against it, and the antibody against the hepatitis B virus nucleus; the correlation of the three symptoms is shown. The presence of HBsAg, HBsAb, and HBcAb is believed to be a contraindication of blood taking for routine purposes; the disappearance of HBsAg for a longer time may justify the re-inclusion among blood donors; the presence of HBsAb and HBcAb does not preclude the preparation of the plasma from such blood for the production of a specific anti-HBs immunoglobulin. (author)

  5. Hepatitis B

    Science.gov (United States)

    ... B Entire Lesson Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For Veterans and the Public Veterans ... in their blood (sometimes referred to as the hepatitis B viral load) and an unusually high level of a ...

  6. Vasopressin and nitroglycerin decrease portal and hepatic venous pressure and hepato-splanchnic blood flow.

    Science.gov (United States)

    Wisén, E; Svennerholm, K; Bown, L S; Houltz, E; Rizell, M; Lundin, S; Ricksten, S-E

    2018-03-26

    Various methods are used to reduce venous blood pressure in the hepato-splanchnic circulation, and hence minimise blood loss during liver surgery. Previous studies show that combination of vasopressin and nitroglycerin reduces portal pressure and flow in patients with portal hypertension, and in this study we investigated this combination in patients with normal portal pressure. In all, 13 patients were studied. Measurements were made twice to confirm baseline (C1 and BL), during vasopressin infusion 4.8 U/h (V), and during vasopressin infusion combined with nitroglycerin infusion (V + N). Portal venous pressure (PVP), hepatic venous pressure (HVP), central haemodynamics and arterial and venous blood gases were obtained at each measuring point, and portal (splanchnic) and hepato-splanchnic blood flow changes were calculated. Vasopressin alone did not affect PVP, whereas HVP increased slightly. In combination with nitroglycerin, PVP decreased from 10.1 ± 1.6 to 8.9 ± 1.3 mmHg (P HVP decreased from 7.9 ± 1.9 to 6.2 ± 1.3 mmHg (P = 0.001). Vasopressin reduced portal blood flow by 47 ± 19% and hepatic venous flow by 11 ± 18%, respectively. Addition of nitroglycerin further reduced portal- and hepatic flow by 55 ± 13% and 30 ± 13%, respectively. Vasopressin alone had minor effects on central haemodynamics, whereas addition of nitroglycerin reduced cardiac index (3.2 ± 0.7 to 2.7 ± 0.5; P < 0.0001). The arterial-portal vein lactate gradient was unaffected. The combination of vasopressin and nitroglycerin decreases portal pressure and hepato-splanchnic blood flow, and could be a potential treatment to reduce bleeding in liver resection surgery. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Hepatitis B and C viral infections among blood donors from rural Ghana.

    Science.gov (United States)

    Nkrumah, B; Owusu, M; Frempong, H O; Averu, P

    2011-09-01

    To investigate the prevalence of Hepatitis B and C infections and co-infections among blood donors in a rural community of Ghana. A retrospective study. Samples of blood donated between January 2007 and December 2008 were screen for Hepatitis B and C viruses at the Agogo Presbyterian Hospital. The prevalence of Hepatitis B viral (HBV) infection was highest in females 21.4% (95% CI: 11.6-34.4) in 2006 than males in the same year 13.2% (95% CI: 10.8-15.9). Hepatitis C viral (HCV) infection was highest among males at 11.6% (95% CI: 9.5-13.8) in 2007. HBV and HCV co-infection was higher in males 2.6% (95% CI: 1.6-3.8) than females 1.3% (95% CI: 0-7.0) in 2007. The overall prevalence of HBV and HCV was 13.8% (95% CI: 11.4-16.4) and 9.4% (95% CI: 7.4-11.6) respectively in 2006. The rate of co-infection of HBV and HCV however increased from 1.6% (95% CI: 0.8-2.7) in 2006 to 2.2% (95% CI: 1.3-3.2) in 2008 in males and from 0% (95% CI: 0-6.4) in 2006 to 1.2% (95% CI: 0-6.5) in 2008 in females. The single infections of HBV and HCV reduced but co-infection of these transfusion transmitted infections (TTI) increased. Measures such as more sensitive techniques and education must be employed in these areas.

  8. Hepatic necro-inflammation and elevated liver enzymes: Evaluation with MRI perfusion imaging with gadoxetic acid in chronic hepatitis patients

    International Nuclear Information System (INIS)

    Chen, B.-B.; Hsu, C.-Y.; Yu, C.-W.; Kao, J.-H.; Lee, H.-S.; Liang, P.-C.; Wei, S.-Y.; Hwang, R.-M.; Shih, T.T.-F.

    2014-01-01

    Aim: To evaluate liver necro-inflammation and function by using gadoxetic acid-enhanced dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), with histological analysis as the reference standard. Materials and methods: Seventy-nine subjects (21 healthy subjects; 58 chronic hepatitis patients) who received gadoxetic acid-enhanced DCE-MRI were divided into three subgroups: no (A0, n = 31), mild (A1, n = 27), and moderate–severe (A2–A3, n = 21) activities. Two DCE-MRI models were measured: (1) a dual-input single-compartment model to obtain absolute arterial, portal venous, and total blood flow, arterial fraction (ART), distribution volume, and mean transit time; (2) a curve analysis method to obtain peak, slope, and AUC (area under curve). The serum alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels also obtained. Statistical testing included Kruskal–Wallis tests for continuous data, Pearson's correlation tests, and multiple linear regression analyses. Results: Hepatic necro-inflammatory activity grades were significantly correlated with fibrotic stages, serum ALT level, ART and AUC. ART was helpful to predict the mild activity (≤A1 versus >A1; Az = 0.728), whereas AUC could differentiate no activity from any activity (A0 versus >A0; Az = 0.703). Peak, slope and AUC were all associated with AST and ALT (p < 0.05). Conclusion: Gadoxetic acid-enhanced DCE-MRI parameters may be used to evaluate the severity of hepatic necro-inflammation and function

  9. Development of an Extracorporeal Perfusion Device for Small Animal Free Flaps.

    Directory of Open Access Journals (Sweden)

    Andreas M Fichter

    Full Text Available Extracorporeal perfusion (ECP might prolong the vital storage capabilities of composite free flaps, potentially opening a wide range of clinical applications. Aim of the study was the development a validated low-cost extracorporeal perfusion model for further research in small animal free flaps.After establishing optimal perfusion settings, a specially designed extracorporeal perfusion system was evaluated during 8-hour perfusion of rat epigastric flaps followed by microvascular free flap transfer. Controls comprised sham-operation, ischemia and in vivo perfusion. Flaps and perfusate (diluted blood were closely monitored by blood gas analysis, combined laser Doppler flowmetry and remission spectroscopy and Indocyanine-Green angiography. Evaluations were complemented by assessment of necrotic area and light microscopy at day 7.ECP was established and maintained for 8 hours with constant potassium and pH levels. Subsequent flap transfer was successful. Notably, the rate of necrosis of extracorporeally perfused flaps (27% was even lower than after in vivo perfusion (49%, although not statistically significant (P = 0,083. After sham-operation, only 6% of the total flap area became necrotic, while 8-hour ischemia led to total flap loss (98%. Angiographic and histological findings confirmed these observations.Vital storage capabilities of microvascular flaps can be prolonged by temporary ECP. Our study provides important insights on the pathophysiological processes during extracorporeal tissue perfusion and provides a validated small animal perfusion model for further studies.

  10. Infectivity of blood products from donors with occult hepatitis B virus infection

    DEFF Research Database (Denmark)

    Allain, Jean-Pierre; Mihaljevic, Ivanka; Gonzalez-Fraile, Maria Isabel

    2013-01-01

    BACKGROUND: Occult hepatitis B virus (HBV) infection (OBI) is identified in 1:1000 to 1:50,000 European blood donations. This study intended to determine the infectivity of blood products from OBI donors. STUDY DESIGN AND METHODS: Recipients of previous donations from OBI donors were investigated...... blood cells [RBCs], p Donor and recipient strains sequence homology of at least 99% confirmed transfusion-transmitted infection in 10 cases and excluded it in one case. CONCLUSION: Blood...... through lookback (systematic retrieval of recipients) or traceback (triggered by clinical cases). Serologic and genomic studies were undertaken on consenting donors and recipients. Multiple variables potentially affecting infectivity were examined. RESULTS: A total of 45 of 105 (42.9%) donor...

  11. Skin perfusion evaluation between laser speckle contrast imaging and laser Doppler flowmetry

    Science.gov (United States)

    Humeau-Heurtier, Anne; Mahe, Guillaume; Durand, Sylvain; Abraham, Pierre

    2013-03-01

    In the biomedical field, laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) are two optical techniques aiming at monitoring - non-invasively - the microvascular blood perfusion. LDF has been used for nearly 40 years whereas LSCI is a recent technique that overcomes some drawbacks of LDF. Both LDF and LSCI give perfusion assessments in arbitrary units. However, the possible relationship existing between perfusions given by LDF and by LSCI over large blood flow values has not been completely studied yet. We therefore herein evaluate the relationship between the LDF and LSCI perfusion values across a broad range of skin blood flows. For this purpose, LDF and LSCI data were acquired simultaneously on the forearm of 12 healthy subjects, at rest, during different durations of vascular occlusion and during reactive hyperemia. For the range of skin blood flows studied, the power function fits the data better than the linear function: powers for individual subjects go from 1.2 to 1.7 and the power is close to 1.3 when all the subjects are studied together. We thus suggest distinguishing perfusion values given by the two optical systems.

  12. Factors in enhancing blood safety by nucleic acid technology testing for human immunodeficiency virus, hepatitis C virus and hepatitis B virus.

    Science.gov (United States)

    Shyamala, Venkatakrishna

    2014-01-01

    In the last few decades through an awareness of transfusion transmitted infections (TTI), a majority of countries have mandated serology based blood screening assays for Human immunodeficiency virus (HIV), Hepatitis C virus (HCV), and Hepatitis B virus (HBV). However, despite improved serology assays, the transfusion transmission of HIV, HCV, and HBV continues, primarily due to release of serology negative units that are infectious because of the window period (WP) and occult HBV infections (OBI). Effective mode of nucleic acid technology (NAT) testing of the viruses can be used to minimize the risk of TTIs. This review compiles the examples of NAT testing failures for all three viruses; analyzes the causes for failure, and the suggestions from retrospective studies to minimize such failures. The results suggest the safest path to be individual donation testing (ID) format for highest sensitivity, and detection of multiple regions for rapidly mutating and recombining viruses. The role of blood screening in the context of the donation and transfusion practices in India, the donor population, and the epidemiology is also discussed. World wide, as the public awareness of TTIs increases, as the recipient rights for safe blood are legally upheld, as the possibility to manage diseases such as hepatitis through expensive and prolonged treatment becomes accessible, and the societal responsibility to shoulder the health costs as in the case for HIV becomes routine, there is much to gain by preventing infections than treating diseases.

  13. Factors in enhancing blood safety by nucleic acid technology testing for human immunodeficiency virus, hepatitis C virus and hepatitis B virus

    Directory of Open Access Journals (Sweden)

    Venkatakrishna Shyamala

    2014-01-01

    Full Text Available In the last few decades through an awareness of transfusion transmitted infections (TTI, a majority of countries have mandated serology based blood screening assays for Human immunodeficiency virus (HIV, Hepatitis C virus (HCV, and Hepatitis B virus (HBV. However, despite improved serology assays, the transfusion transmission of HIV, HCV, and HBV continues, primarily due to release of serology negative units that are infectious because of the window period (WP and occult HBV infections (OBI. Effective mode of nucleic acid technology (NAT testing of the viruses can be used to minimize the risk of TTIs. This review compiles the examples of NAT testing failures for all three viruses; analyzes the causes for failure, and the suggestions from retrospective studies to minimize such failures. The results suggest the safest path to be individual donation testing (ID format for highest sensitivity, and detection of multiple regions for rapidly mutating and recombining viruses. The role of blood screening in the context of the donation and transfusion practices in India, the donor population, and the epidemiology is also discussed. World wide, as the public awareness of TTIs increases, as the recipient rights for safe blood are legally upheld, as the possibility to manage diseases such as hepatitis through expensive and prolonged treatment becomes accessible, and the societal responsibility to shoulder the health costs as in the case for HIV becomes routine, there is much to gain by preventing infections than treating diseases.

  14. Improvements in the technique of vascular perfusion-fixation employing a fluorocarbon-containing perfusate and a peristaltic pump controlled by pressure feedback

    DEFF Research Database (Denmark)

    Rostgaard, J; Qvortrup, Klaus; Poulsen, Steen Seier

    1993-01-01

    A new improved technique for whole-body perfusion-fixation of rats and other small animals is described. The driving force is a peristaltic pump which is feedback regulated by a pressure transducer that monitors the blood-perfusion pressure in the left ventricle of the heart. The primary perfusate...... to cannulate the heart; the outer and inner barrels of the cannula are connected to the peristaltic pump and to the pressure transducer, respectively. The tissue oxygen tension in the rat is monitored by a subcutaneous oxygen electrode. Measurements showed that tissue hypoxia/anoxia did not develop before......-fixative is composed of a blood substitute--13.3% oxygenated fluorocarbon FC-75--in 0.05 M cacodylate buffer (pH 7.4) with a 2% glutaraldehyde. The secondary perfusate-fixative is composed of 2% glutaraldehyde in 0.05 M cacodylate buffer (pH 7.4) with 20 mM CaCl2. A double-barrelled, self-holding cannula is used...

  15. Effect of Defocused CO2 Laser on Equine Tissue Perfusion

    Directory of Open Access Journals (Sweden)

    Bergh A

    2006-03-01

    Full Text Available Treatment with defocused CO2 laser can have a therapeutic effect on equine injuries, but the mechanisms involved are unclear. A recent study has shown that laser causes an increase in equine superficial tissue temperature, which may result in an increase in blood perfusion and a stimulating effect on tissue regeneration. However, no studies have described the effects on equine tissue perfusion. The aim of the present study was to investigate the effect of defocused CO2 laser on blood perfusion and to correlate it with temperature in skin and underlying muscle in anaesthetized horses. Differences between clipped and unclipped haircoat were also assessed. Eight horses and two controls received CO2 laser treatment (91 J/cm2 in a randomised order, on a clipped and unclipped area of the hamstring muscles, respectively. The significant increase in clipped skin perfusion and temperature was on average 146.3 ± 33.4 perfusion units (334% and 5.5 ± 1.5°C, respectively. The significant increase in perfusion and temperature in unclipped skin were 80.6 ± 20.4 perfusion units (264% and 4.8 ± 1.4°C. No significant changes were seen in muscle perfusion or temperature. In conclusion, treatment with defocused CO2 laser causes a significant increase in skin perfusion, which is correlated to an increase in skin temperature.

  16. Blood flow and tissue oxygen pressures of liver and pancreas in rats: effects of volatile anesthetics and of hemorrhage.

    Science.gov (United States)

    Vollmar, B; Conzen, P F; Kerner, T; Habazettl, H; Vierl, M; Waldner, H; Peter, K

    1992-09-01

    The object of this investigation was to compare the effects of volatile anesthetics and of hemorrhage at comparable arterial blood pressures on splanchnic blood flow (radioactive microspheres) and tissue oxygenation of the liver and pancreas (surface PO2 [PSO2] electrodes). In contrast to earlier studies, we did not use identical minimum alveolar anesthetic concentration multiples as a reference to compare volatile anesthetics; rather, we used the splanchnic perfusion pressure. Under general anesthesia (intravenous chloralose) and controlled ventilation, 12 Sprague-Dawley rats underwent laparotomy to allow access to abdominal organs. Mean arterial pressure was decreased from 84 +/- 3 mm Hg (mean +/- SEM) at control to 50 mm Hg by 1.0 +/- 0.1 vol% halothane, 2.2 +/- 0.2 vol% enflurane, and 2.3 +/- 0.1 vol% isoflurane in a randomized sequence. For hemorrhagic hypotension, blood was withdrawn gradually until a mean arterial pressure of 50 mm Hg was attained. Volatile anesthetics and hemorrhage reduced cardiac output, and hepatic arterial, portal venous, and total hepatic blood flows by comparable degrees. Mean hepatic PSO2 decreased significantly from 30.7 +/- 2.6 mm Hg at control to 17.4 +/- 2 and 17.5 +/- 2 mm Hg during enflurane and isoflurane (each P less than 0.05) anesthesia, respectively. The decrease to 11.5 +/- 2.5 mm Hg was more pronounced during halothane anesthesia. Hemorrhagic hypotension was associated with the lowest hepatic PSO2 (3.4 +/- 1.3 mm Hg) and the highest number of hypoxic (0-5 mm Hg 86%) and anoxic PSO2 values (0 mm Hg 46%). Pancreatic blood flow and oxygenation remained unchanged from control during halothane and enflurane administration, whereas isoflurane increased both variables. Hemorrhagic hypotension slightly reduced pancreatic flow (-8%) but significantly decreased PSO2 from 58 +/- 5 mm Hg at control to 36 +/- 3 mm Hg, with 7% of all measured values in the hypoxic range. Thus, volatile anesthetics preserved pancreatic but not hepatic

  17. The effect of prior transfusion history on blood donor anti-hepatitis C virus antibody.

    Science.gov (United States)

    Mazda, T; Nakata, K; Ota, K; Kaminuma, Y; Katayama, T

    1993-01-01

    In Japan, the major transfusion-associated disease is non-A, non-B hepatitis. We studied the relationship between transfusion history and blood donor antibodies to hepatitis C virus (HCV). The positive rate of antibodies to the HCV nonstructural protein (c100-3) depended on age and the time elapsed since transfusion. The anti-c100-3 ratio for subjects with transfusions made prior to 20 years ago was high. One quarter century ago, a change occurred in national blood policy from paid to non-paid voluntary donations. We also have studied the anti-HCV positive rate among donors with prior transfusion using a second generation HCV test kit which includes anti-HCV core antibody detection. The anti-HCV positive rate for the second generation test was higher than that for the anti-c100-3 test. Introduction of the second generation test is therefore more useful in screening than the anti-c100-3 test for blood programs.

  18. Studies on glucose metabolism and blood perfusion in childhood partial seizure by positron emission CT

    International Nuclear Information System (INIS)

    Michihiro, Narumi

    1986-01-01

    To investigate the glucose metabolism and blood perfusion of the interictal epileptic focus, 15 positron emission tomography (PET) measurements were performed in 14 children with partial seizures (2 with simple partial seizures, 2 with complex partial seizures, and 10 with partial seizures evolving to secondary generalized seizures), comprising 7 males and 7 females aged 1 to 12 years old at the onset of the epileptic seizures. The intervals between the seizure onset and PET examinations were 1 month to 7 years (mean 3 1/4 years). Radiopharmaceuticals such as 11 C-glucose, 11 CO 2 and 11 CO were used as indicators of local cerebral glucose metabolism, blood perfusion and blood flow, respectively. Apart from 2 cases, none of the patients showed abnormal x-ray computed tomographic scans (X-CT). The abnormal X-CT findings included cortical atrophy of the cerebrum apart from the epiletic focus in one case and cavum vergae in the other. Hypometabolism and hypoperfusion at the epileptic focus were observed in 10 patients undergoing single examinations who had suffered from epileptic seizures for more than 1 year. Out of 4 patients who had suffered from epileptic seizures for 1 year or less, one revealed a zone of hypometabolism and hypoperfusion in the epileptic focus and expanded region larger than that of the epileptic focus on the electroencephalogram. Two other patients revealed a zone of hypometabolism and hypoperfusion in an area contralateral to the epileptic focus. In the remaining one patient, PET examinations were performed twice. The initial PET pictures one year after seizure onset revealed a zone of hypermetabolism and hyperperfusion in the cerebellum ipsilateral to the epileptic focus, and the second PET at 6 months after the initial examination revealed hypometabolism and hypoperfusion in the focus, similarly to the 10 cases mentioned above. (J.P.N.)

  19. Discrepancy between microsphere and diffusible tracer estimates of perfusion to ischemic myocardium

    International Nuclear Information System (INIS)

    Yoshida, S.; Akizuki, S.; Gowski, D.; Downey, J.M.

    1985-01-01

    This study critically tests the ability of microspheres to accurately measure perfusion to ischemic myocardium. The left anterior descending coronary artery was cannulated and perfused with arterial blood. The perfusion line was clamped, and a sidearm between the clamp and the cannula was opened to the atmosphere, allowing blood to flow retrograde from the distal segment of the artery. Measurement of regional blood flow during retrograde flow diversion with 15-micron microspheres revealed essentially zero flow to the perfused segment (0.005 ml X min-1 X g-1). Measurements under the same conditions by either 86 Rb uptake or 133 Xe washout revealed that an appreciable perfusion of the tissue persisted during retrograde flow diversion (0.043 and 0.11 ml X min-1 X g-1, respectively, for the 2 methods). Thus, the authors have identified a condition during which microspheres indicate zero flow to the tissue but diffusible tracers can both be washed in and washed out at a brisk rate. They conclude that with simple occlusion there is a hidden component of perfusion to an ischemic zone that cannot be measured by microspheres, causing them to underestimate flow by about 25% in that condition

  20. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  1. Transfusion-associated hepatitis before the screening of blood for hepatitis risk factors

    DEFF Research Database (Denmark)

    Engle, Ronald E; Bukh, Jens; Alter, Harvey J

    2014-01-01

    %) with HBV alone, and one (3%) with both viruses. Overall, 100% of patients with hepatitis and 39% of those without hepatitis were infected with HBV and/or HCV; one patient was also infected with hepatitis E virus. The donor carrier rate for HBV and/or HCV was estimated to be more than 6%; contemporaneously......%) developed biochemical evidence of hepatitis; of these, 20 (67%) were infected with hepatitis C virus (HCV) alone, four (13%) with hepatitis B virus (HBV) alone, and six (20%) with both viruses. Among the 36 patients who did not develop hepatitis, four (11%) were newly infected with HCV alone, nine (25...... prepared pooled normal human plasma was also contaminated with multiple hepatitis viruses. CONCLUSION: TAH virus infections were a larger problem than perceived 50 years ago and HCV was the predominant agent transmitted. All hepatitis cases could be attributed to HCV and/or HBV and hence...

  2. Optical diagnostic of hepatitis B (HBV) and C (HCV) from human blood serum using Raman spectroscopy

    International Nuclear Information System (INIS)

    Anwar, Shahzad; Firdous, Shamaraz

    2015-01-01

    Hepatitis is the second most common disease worldwide with half of the cases arising in the developing world. The mortality associated with hepatitis B and C can be reduced if the disease is detected at the early stages of development. The aim of this study was to investigate the potential of Raman spectroscopy as a diagnostic tool to detect biochemical changes accompanying hepatitis progression. Raman spectra were acquired from 20 individuals with six hepatitis B infected patients, six hepatitis C infected patients and eight healthy patients in order to gain an insight into the determination of biochemical changes for early diagnostic. The human blood serum was examined at a 532 nm excitation laser source. Raman characteristic peaks were observed in normal sera at 1006, 1157 and 1513 cm −1 , while in the case of hepatitis B and C these peaks were found to be blue shifted with decreased intensity. New Raman peaks appeared in HBV and HCV infected sera at 1194, 1302, 844, 905, 1065 and 1303 cm −1 respectively. A Mat lab subroutine and frequency domain filter program is developed and applied to signal processing of Raman scattering data. The algorithms have been successfully applied to remove the signal noise found in experimental scattering signals. The results show that Raman spectroscopy displays a high sensitivity to biochemical changes in blood sera during disease progression resulting in exceptional prediction accuracy when discriminating between normal and malignant. Raman spectroscopy shows enormous clinical potential as a rapid non-invasive diagnostic tool for hepatitis and other infectious diseases. (letter)

  3. Optical diagnostic of hepatitis B (HBV) and C (HCV) from human blood serum using Raman spectroscopy

    Science.gov (United States)

    Anwar, Shahzad; Firdous, Shamaraz

    2015-06-01

    Hepatitis is the second most common disease worldwide with half of the cases arising in the developing world. The mortality associated with hepatitis B and C can be reduced if the disease is detected at the early stages of development. The aim of this study was to investigate the potential of Raman spectroscopy as a diagnostic tool to detect biochemical changes accompanying hepatitis progression. Raman spectra were acquired from 20 individuals with six hepatitis B infected patients, six hepatitis C infected patients and eight healthy patients in order to gain an insight into the determination of biochemical changes for early diagnostic. The human blood serum was examined at a 532 nm excitation laser source. Raman characteristic peaks were observed in normal sera at 1006, 1157 and 1513 cm-1, while in the case of hepatitis B and C these peaks were found to be blue shifted with decreased intensity. New Raman peaks appeared in HBV and HCV infected sera at 1194, 1302, 844, 905, 1065 and 1303 cm-1 respectively. A Mat lab subroutine and frequency domain filter program is developed and applied to signal processing of Raman scattering data. The algorithms have been successfully applied to remove the signal noise found in experimental scattering signals. The results show that Raman spectroscopy displays a high sensitivity to biochemical changes in blood sera during disease progression resulting in exceptional prediction accuracy when discriminating between normal and malignant. Raman spectroscopy shows enormous clinical potential as a rapid non-invasive diagnostic tool for hepatitis and other infectious diseases.

  4. The role of blood transfusion on the prevalence of hepatitis c virus ...

    African Journals Online (AJOL)

    Background: The hepatitis C Virus (HCV) has become an important cause of chronic liver disease and liver cancerworldwide. Blood transfusion is one of the importantmodes of transmission. There is need to study the prevalence among those at risk such as sickle cell anaemia (SCA) patients. Such information will broaden ...

  5. Silent hepatitis E virus infection in Dutch blood donors, 2011 to 2012

    NARCIS (Netherlands)

    Slot, E.; Hogema, B. M.; Riezebos-Brilman, A.; Kok, T. M.; Molier, M.; Zaaijer, H. L.

    2013-01-01

    In Europe, the dynamics of endemic hepatitis E virus (HEV) infection remain enigmatic. We studied the presence of silent HEV infection among Dutch blood donors. Using donations collected throughout the Netherlands in 2011 and 2012, 40,176 donations were tested for HEV RNA in 459 pools of 48 or 480

  6. Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies

    International Nuclear Information System (INIS)

    Murase, Kenya; Nanjo, Takafumi; Ii, Satoshi; Miyazaki, Shohei; Hirata, Masaaki; Sugawara, Yoshifumi; Kudo, Masayuki; Sasaki, Kousuke; Mochizuki, Teruhito

    2005-01-01

    The purpose of this study was to investigate the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using multi-detector row CT (MDCT). Following the standard CT perfusion study protocol, continuous (cine) scans (1 s/rotation x 60 s) consisting of four 5 mm thick contiguous slices were performed using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. We generated the simulated images with tube currents of 50 mA, 100 mA and 150 mA by adding the corresponding noise to the raw scan data of the original image acquired above using a noise simulation tool. From the original and simulated images, we generated the functional images of cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) in seven patients with cerebrovascular disease, and compared the correlation coefficients (CCs) between the perfusion parameter values obtained from the original and simulated images. The coefficients of variation (CVs) in the white matter were also compared. The CC values deteriorated with decreasing tube current. There was a significant difference between 50 mA and 100 mA for all perfusion parameters. The CV values increased with decreasing tube current. There were significant differences between 50 mA and 100 mA and between 100 mA and 150 mA for CBF. For CBV and MTT, there was also a significant difference between 150 mA and 200 mA. This study will be useful for understanding the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using MDCT, and for selecting the tube current

  7. Hepatic parenchymal perfusion abnormalities after pancreaticobiliary surgery. Evaluation with dynamic helical CT

    International Nuclear Information System (INIS)

    Mitsuzaki, K.; Yamashita, Y.; Ogata, I.; Nishiharu, T.; Urata, J.; Takahashi, M.

    1998-01-01

    Purpose: To evaluate perfusion abnormalities of the liver after pancreaticobiliary surgery. Material and Methods: We retrospectively evaluated 128 patients with pancreaticobiliary malignant tumors who had been examined both before and after surgery by means of helical CT of the liver. An infusion of 3 ml/s of 60% nonionic contrast material was followed by helical CT of the liver in a sequential arterial phase, portal venous phase, and equilibrium phase. Results: Of 128 patients, we followed 97. In 21 patients (22%) we found 47 lesions with perfusion abnormalities that were detected 1-33 months (mean 6.6 months) after the operation. All patients were asymptomatic. The shape of each perfusion abnormality was characterized as geographic (n=23, 47%), wedge-shaped (n=21, 45%), or round (n=3, 8%). The abnormalities were seen in the arterial phase in 46 lesions (98%), in the portal venous phase in 18 lesions (38%), and in the equilibrium phase in 1 lesion (0.2%). In all lesions, the size either decreased spontaneously, or it remained unchanged for more than one year. Conclusion: Perfusion abnormalities of the liver may occur in patients who undergo pancreaticobiliary surgery. These findings should not be confused with hypervascular metastases. (orig.)

  8. Hepatic parenchymal perfusion abnormalities after pancreaticobiliary surgery. Evaluation with dynamic helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsuzaki, K.; Yamashita, Y.; Ogata, I.; Nishiharu, T.; Urata, J.; Takahashi, M. [Kumamoto Univ., School of Medicine, Dept. of Radiology (Japan)

    1998-05-01

    Purpose: To evaluate perfusion abnormalities of the liver after pancreaticobiliary surgery. Material and Methods: We retrospectively evaluated 128 patients with pancreaticobiliary malignant tumors who had been examined both before and after surgery by means of helical CT of the liver. An infusion of 3 ml/s of 60% nonionic contrast material was followed by helical CT of the liver in a sequential arterial phase, portal venous phase, and equilibrium phase. Results: Of 128 patients, we followed 97. In 21 patients (22%) we found 47 lesions with perfusion abnormalities that were detected 1-33 months (mean 6.6 months) after the operation. All patients were asymptomatic. The shape of each perfusion abnormality was characterized as geographic (n=23, 47%), wedge-shaped (n=21, 45%), or round (n=3, 8%). The abnormalities were seen in the arterial phase in 46 lesions (98%), in the portal venous phase in 18 lesions (38%), and in the equilibrium phase in 1 lesion (0.2%). In all lesions, the size either decreased spontaneously, or it remained unchanged for more than one year. Conclusion: Perfusion abnormalities of the liver may occur in patients who undergo pancreaticobiliary surgery. These findings should not be confused with hypervascular metastases. (orig.).

  9. Prevalence of hepatitis A viral RNA and antibodies among Chinese blood donors.

    Science.gov (United States)

    Sun, P; Su, N; Lin, F Z; Ma, L; Wang, H J; Rong, X; Dai, Y D; Li, J; Jian, Z W; Tang, L H; Xiao, W; Li, C Q

    2015-12-09

    Like other developing countries, China was reported to have a relatively high seroprevalence of anti-hepatitis A antibodies (anti-HAV). However, no studies have evaluated the prevalence of anti-HAV and HAV RNA among voluntary blood donors with or without elevated serum alanine transaminase (ALT) levels. Anti-HAV antibodies were detected using an enzyme-linked immunosorbent assay, and reverse transcription quantitative polymerase chain reaction was carried out for detection of HAV RNA. In the current study, we analyzed a total of 450 serum samples with elevated ALT levels (≥40 U/L) and 278 serum samples with non-elevated ALT levels. Seroprevalence rates of anti-HAV were 51.6% in donors with elevated ALT and 41.4% in donors with non-elevated ALT; however, none of the samples was positive for HAV RNA. The results of our study showed lower seroprevalence rates of anti-HAV in blood donors (irrespective of ALT levels) than those in published data on Chinese populations. Although donors with elevated ALT had statistically higher prevalence rates of anti- HAV than did those with non-elevated ALT, none of the serum samples had detectable levels of the active virus. In conclusion, our results demonstrate that the transmission of hepatitis A by blood transfusion will occur rarely.

  10. Syngeneic peripheral blood stem cell transplantation with immunosuppression for hepatitis-associated severe aplastic anemia

    Directory of Open Access Journals (Sweden)

    Aleksandar Savic

    2010-12-01

    Full Text Available Hepatitis-associated aplastic anemia occurs in up to 10% of all aplastic anemia cases. Syngeneic bone marrow transplantation is rare in patients with severe aplastic anemia and usually requires pre-transplant conditioning to provide engraftment. We report on a 29-year-old male patient with hepatitis-associated severe aplastic anemia who had a series of severe infectious conditions before transplantation, including tracheal inflammation. Life-threatening bleeding, which developed after bronchoscopy, was successfully treated with activated recombinant factor VII and platelet transfusions. Syngeneic peripheral blood stem cell transplantation using immunosuppressive treatment with antithymocyte globulin and cyclosporin A without high-dose pre-transplant conditioning was performed, followed by complete hematologic and hepatic recovery.

  11. Pulmonary artery perfusion versus no perfusion during cardiopulmonary bypass for open heart surgery in adults

    DEFF Research Database (Denmark)

    Buggeskov, Katrine B; Grønlykke, Lars; Risom, Emilie C

    2018-01-01

    BACKGROUND: Available evidence has been inconclusive on whether pulmonary artery perfusion during cardiopulmonary bypass (CPB) is associated with decreased or increased mortality, pulmonary events, and serious adverse events (SAEs) after open heart surgery. To our knowledge, no previous systematic...... handsearched retrieved study reports and scanned citations of included studies and relevant reviews to ensure that no relevant trials were missed. We searched for ongoing trials and unpublished trials in the World Health Organization International Clinical Trials Registry Platform (ICTRP) and at clinicaltrials......). We used GRADE principles to assess the quality of evidence. MAIN RESULTS: We included in this review four RCTs (210 participants) reporting relevant outcomes. Investigators randomly assigned participants to pulmonary artery perfusion with blood versus no perfusion during CPB. Only one trial included...

  12. Seroprevalence of Human Immunodeficiency Virus, Hepatitis B Virus, Hepatitis C Virus, and Treponema pallidum Infections among Blood Donors on Bioko Island, Equatorial Guinea.

    Directory of Open Access Journals (Sweden)

    Dong-De Xie

    Full Text Available Regular screening of transfusion-transmissible infections (TTIs, such as human immunodeficiency virus (HIV, hepatitis B and hepatitis C virus (HBV and HCV, respectively, and Treponema pallidum, in blood donors is essential to guaranteeing clinical transfusion safety. This study aimed to determine the seroprevalence of four TTIs among blood donors on Bioko Island, Equatorial Guinea (EG.A retrospective survey of blood donors from January 2011 to April 2013 was conducted to assess the presence of HIV, HBV, HCV and T. pallidum. The medical records were analyzed to verify the seroprevalence of these TTIs among blood donations stratified by gender, age and geographical region.Of the total 2937 consecutive blood donors, 1098 (37.39% had a minimum of one TTI and 185 (6.29% harbored co-infections. The general seroprevalence of HIV, HBV, HCV and T. pallidum were 7.83%, 10.01%, 3.71% and 21.51%, respectively. The most frequent TTI co-infections were HBV-T. pallidum 60 (2.04% and HIV-T. pallidum 46 (1.57%. The seroprevalence of HIV, HBV, HCV and T. pallidum were highest among blood donors 38 to 47 years, 18 to 27 years and ≥ 48 years age, respectively (P<0.05. The seroprevalence of TTIs varied according to the population from which the blood was collected on Bioko Island.Our results firstly provide a comprehensive overview of TTIs among blood donors on Bioko Island. Strict screening of blood donors and improved hematological examinations using standard operating procedures are recommended.

  13. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  14. Detection of antibody against antigen expressed by molecularly cloned hepatitis C virus cDNA: Application to diagnosis and blood screening for posttransfusion hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Miyamura, Tatsuo; Saito, Izumu (National Institute of Health, Tokyo (Japan)); Katayama, Tohru (Tokyo National Chest Hospital (Japan)); Kikuchi, Shu; Tateda, Akira (Sendai National Hospital (Japan)); Houghton, M.; Choo, Quilim; Kuo, G. (Chiron Corporation, Emeryville, CA (USA))

    1990-02-01

    A cDNA clone has been derived from the plasma of a chimpanzee with chronic non-A, non-B viral hepatits (NANBH). The authors have assayed for antibodies reacting with the encoded antigen in sera from posttransfusion hepatitis patients (643 samples from 23 patients) and their corresponding donors collected during the past 10 years in Japan. The antibody was detected in 15 out of 17 (88.2%) posttransfusion NANBH (PT-NANBH) patients whose sera over time displayed multiple alanine aminotransferase (ALT) peaks. In general, the antibody was detected after several peaks of serum ALT elevations and, once detected, it persisted for years. Of the 15 well-defined cases of PT-NANBH that showed multiple ALT peaks and hepatitis C virus seroconversions, 11 (73.3%) were shown to be transfused with at least one unit of blood positive for the antibody. The retrospective analysis showed that all tested donor blood found to be positive for the antibody had been transfused to recipients who afterwards developed NANBH. These data strongly suggest that the cloned cDNA originated from an etiological agent of NANBH termed the hepatitis C virus. Furthermore, the present study demonstrates that had the screening been done with the anti-hepatitis C virus assay, 11 out of 17 (64.7%) cases of chronic PT-NANBH and 1 out of 6 (16.6%) acute PT-NANBH would have been prevented.

  15. Detection of antibody against antigen expressed by molecularly cloned hepatitis C virus cDNA: Application to diagnosis and blood screening for posttransfusion hepatitis

    International Nuclear Information System (INIS)

    Miyamura, Tatsuo; Saito, Izumu; Katayama, Tohru; Kikuchi, Shu; Tateda, Akira; Houghton, M.; Choo, Quilim; Kuo, G.

    1990-01-01

    A cDNA clone has been derived from the plasma of a chimpanzee with chronic non-A, non-B viral hepatits (NANBH). The authors have assayed for antibodies reacting with the encoded antigen in sera from posttransfusion hepatitis patients (643 samples from 23 patients) and their corresponding donors collected during the past 10 years in Japan. The antibody was detected in 15 out of 17 (88.2%) posttransfusion NANBH (PT-NANBH) patients whose sera over time displayed multiple alanine aminotransferase (ALT) peaks. In general, the antibody was detected after several peaks of serum ALT elevations and, once detected, it persisted for years. Of the 15 well-defined cases of PT-NANBH that showed multiple ALT peaks and hepatitis C virus seroconversions, 11 (73.3%) were shown to be transfused with at least one unit of blood positive for the antibody. The retrospective analysis showed that all tested donor blood found to be positive for the antibody had been transfused to recipients who afterwards developed NANBH. These data strongly suggest that the cloned cDNA originated from an etiological agent of NANBH termed the hepatitis C virus. Furthermore, the present study demonstrates that had the screening been done with the anti-hepatitis C virus assay, 11 out of 17 (64.7%) cases of chronic PT-NANBH and 1 out of 6 (16.6%) acute PT-NANBH would have been prevented

  16. Regional myocardial perfusion of cardioplegic solutions

    International Nuclear Information System (INIS)

    Eugene, J.; Lyons, K.P.; Ott, R.A.; Gelezunas, V.L.; Chang, C.W.; Kowall, M.G.; Haiduc, N.J.

    1987-01-01

    We compared the regional myocardial perfusion of blood cardioplegic solution (BCP) and crystalloid cardioplegic solution (CCP) in 14 mongrel dogs. Cardiopulmonary bypass was established at 28 degrees C, and a hydraulic occluder was placed around the proximal left anterior descending (LAD) coronary artery. In group 1 (N = 7) collateral coronary arteries were ligated; in group 2 (N = 7) collateral coronary arteries were left in situ. After the aorta was clamped, BCP and CCP were alternately perfused at 200 ml/min. The occluder was inflated to produce moderate, severe, and critical LAD stenosis, and regional perfusion was measured by xenon-133 washout with the Silicon Avalanche Radiation Detector. BCP infusion produced a consistently higher aortic pressure, but CCP flow was better than BCP flow under all conditions, particularly without coronary collaterals. Regional myocardial perfusion of CCP is superior to BCP

  17. Epidemiology of hepatitis B virus infection in first-time blood donors in the southwestern region of Goiás, central Brazil

    Directory of Open Access Journals (Sweden)

    Giulena Rosa Leite Cardoso dos Anjos

    2011-02-01

    Full Text Available INTRODUCTION: Little is known about the epidemiology of hepatitis B virus (HBV infection in populations from inner cities, especially in Central Brazil. Thus the objective of this study was to estimate the prevalence of HBV infection, and to analyze the factors associated with HBV infection, in a population of first-time blood donors in the southwestern region of Goiás, Central Brazil. METHODS: A total of 984 individuals were interviewed and gave blood samples to detect serological markers of HBV (HBsAg, anti-HBs, and anti-HBc by enzyme linked immunosorbent assays. RESULTS: An overall prevalence of 6.9% was found for HBV, with constituent prevalence rates of 3.6% and 11.6%, in subjects classified as fit and unfit to donate blood according the epidemiological screening, respectively. Only three individuals were positive for anti-HBs alone, suggesting previous vaccination against HBV. The variables of prior blood transfusion (OR = 2.3, tattoo/piercing (OR = 2.1, illicit drug use (OR = 2.3, sex with a partner with hepatitis (OR = 14.7, and history of sexually transmitted diseases (OR = 2.9 were independently associated with HBV-positivity. These data suggested a low endemicity of hepatitis B in the studied population. CONCLUSION: The findings of low hepatitis B immunization coverage and the association of hepatitis B with risky behavior highlight that there is a need to intensify hepatitis B prevention programs in the southwest region of Goiás.

  18. Evaluation of cerebral perfusion imaging with N-isopropyl-p-[123I]iodoamphetamine (IMP) in the cases of antiphospholipid syndrome

    International Nuclear Information System (INIS)

    Kato, Toru; Nanbu, Ichiro; Tohyama, Junko; Ohba, Satoru

    1995-01-01

    Five cases of antiphospholipid syndrome with mild headache, but without any neurological deficits and abnormal findings by CT and MRI, were examined by cerebral blood perfusion SPECT using N-isopropyl-p-[ 123 I] iodoamphetamine (IMP). Although three cases were performed quantification of cerebral blood flow with a microsphere method simultaneously, their values were within normal limits. Two of them showed focal low perfusion areas. One case had relatively low perfusion areas in the bilateral occipital lobes and the right temporal lobe, which improved after treatment. One of two had low perfusion in the bilateral occipital lobes. Other three cases only showed ununiformity of radioisotope uptake on the cerebral blood perfusion SPECT. Low perfusion areas in antiphospholipid syndrome might be caused by microarterial thrombosis, microvenous thrombosis or spasms, although they could be reversible. As early irreversible progress of cerebral blood flow, cerebral blood flow SPECT should be performed in cases of antiphospholipid syndrome with neurological complainments. (author)

  19. Dual-energy perfusion-CT in recurrent pancreatic cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, F.; Skornitzke, S.; Kauczor, H.U.; Stiller, W.; Klauss, M. [Heidelberg Univ. (Germany). Clinic of Diagnostic and Interventional Radiology; Hackert, T. [Heidelberg Univ. (Germany). Clinic of Surgery; Grenacher, L. [Diagnostik Muenchen (Germany). Diagnostic Imaging Center

    2016-06-15

    To evaluate the diagnostic performance of dual energy (DE) perfusion-CT for the differentiation between postoperative soft-tissue formation and tumor recurrence in patients after potentially curative pancreatic cancer resection. 24 patients with postoperative soft-tissue formation in the conventional regular follow-up CT acquisition after pancreatic cancer resection with curative intent were included prospectively. They were examined with a 64-row dual-source CT using a dynamic sequence of 34 DE acquisitions every 1.5 s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). Weighted average (linearly blended M0.5) 120 kVp-equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool for estimating blood flow, permeability, and blood volume. Diagnosis was confirmed by histological study (n=4) and by regular follow-up. Final diagnosis was local recurrence of pancreatic cancer in 15 patients and unspecific postoperative tissue formation in 9 patients. The blood-flow values for recurrence tissue trended to be lower compared to postoperative tissue formation with 16.6 ml/100 ml/min and 24.7 ml/100 ml/min, respectively for weighted average 120 kVp-equivalent image data, which was not significant (n.s.) (p=0.06, significance level 0.05). Permeability- and blood-volume values were only slightly lower in recurrence tissue (n.s.). DE perfusion-CT is feasible in patients after pancreatic cancer resection and a promising functional imaging technique. As only a trend for lower perfusion values in local recurrence compared to unspecific postoperative alterations was found, the perfusion differences are not yet sufficient to differentiate between malignancy and unspecific postoperative alterations for this new technique. Further studies and technical improvements are needed to generate reliable data for this clinically highly relevant differentiation.

  20. Decreased blood hepatitis B surface antibody levels linked to e-waste lead exposure in preschool children

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xijin [Laboratory of Environmental Medicine and Developmental Toxicology, and Guangdong Provincial Key Laboratory of Infectious Diseases, Shantou University Medical College, Shantou 515041, Guangdong (China); Department of Cell Biology and Genetics, Shantou University Medical College, Shantou 515041, Guangdong (China); Chen, Xiaojuan; Zhang, Jian [Laboratory of Environmental Medicine and Developmental Toxicology, and Guangdong Provincial Key Laboratory of Infectious Diseases, Shantou University Medical College, Shantou 515041, Guangdong (China); Guo, Pi [Department of Public Health, Shantou University Medical College, Shantou 515041, Guangdong (China); Fu, Tingzao; Dai, Yifeng [Laboratory of Environmental Medicine and Developmental Toxicology, and Guangdong Provincial Key Laboratory of Infectious Diseases, Shantou University Medical College, Shantou 515041, Guangdong (China); Lin, Stanley L. [Department of Pathophysiology and Key Immunopathology Laboratory of Guangdong Province, Shantou University Medical College, Shantou 515041, Guangdong (China); Huo, Xia, E-mail: xhuo@stu.edu.cn [Laboratory of Environmental Medicine and Developmental Toxicology, and Guangdong Provincial Key Laboratory of Infectious Diseases, Shantou University Medical College, Shantou 515041, Guangdong (China)

    2015-11-15

    Highlights: • Secondary exploratory analyses displayed a correlation of blood Pb to HBsAb levels. • Generalized linear mixed models were used to analyze two-phase data. • Children from an e-waste area had higher blood Pb levels and lower HBsAb titers. • Nearly 50% of Pb-exposed children fail to develop sufficient HBV immunity. • Different vaccination strategies are required for in e-waste areas. - Abstract: Lead (Pb) is a widespread environmental contaminant that can profoundly affect the immune system in vaccinated children. To explore the association between blood Pb and HBsAb levels in children chronically exposed to Pb, we measured hepatitis B surface antibody (HBsAb) titers, to reflect the immune response in the children of Guiyu, an electronic and electrical waste (e-waste) recycling area well known for environmental Pb contamination. We performed secondary exploratory analyses of blood Pb levels and plasma HBsAb titers in samples, taken in two phases between 2011 and 2012, from 590 children from Guiyu (exposed group) and Haojiang (reference group). Children living in the exposed area had higher blood Pb levels and lower HBsAb titers compared with children from the reference area. At each phase, generalized linear mixed models (GLMMs) showed that HBsAb titers were significantly negatively associated with child blood Pb levels. This work shows that a decreased immune response to hepatitis B vaccine and immune system might have potential harm to children with chronic Pb exposure. Importantly, nearly 50% of chronically exposed children failed to develop sufficient immunity to hepatitis in response to vaccination. Thus different vaccination strategies are needed for children living under conditions of chronic Pb exposure.

  1. Decreased blood hepatitis B surface antibody levels linked to e-waste lead exposure in preschool children

    International Nuclear Information System (INIS)

    Xu, Xijin; Chen, Xiaojuan; Zhang, Jian; Guo, Pi; Fu, Tingzao; Dai, Yifeng; Lin, Stanley L.; Huo, Xia

    2015-01-01

    Highlights: • Secondary exploratory analyses displayed a correlation of blood Pb to HBsAb levels. • Generalized linear mixed models were used to analyze two-phase data. • Children from an e-waste area had higher blood Pb levels and lower HBsAb titers. • Nearly 50% of Pb-exposed children fail to develop sufficient HBV immunity. • Different vaccination strategies are required for in e-waste areas. - Abstract: Lead (Pb) is a widespread environmental contaminant that can profoundly affect the immune system in vaccinated children. To explore the association between blood Pb and HBsAb levels in children chronically exposed to Pb, we measured hepatitis B surface antibody (HBsAb) titers, to reflect the immune response in the children of Guiyu, an electronic and electrical waste (e-waste) recycling area well known for environmental Pb contamination. We performed secondary exploratory analyses of blood Pb levels and plasma HBsAb titers in samples, taken in two phases between 2011 and 2012, from 590 children from Guiyu (exposed group) and Haojiang (reference group). Children living in the exposed area had higher blood Pb levels and lower HBsAb titers compared with children from the reference area. At each phase, generalized linear mixed models (GLMMs) showed that HBsAb titers were significantly negatively associated with child blood Pb levels. This work shows that a decreased immune response to hepatitis B vaccine and immune system might have potential harm to children with chronic Pb exposure. Importantly, nearly 50% of chronically exposed children failed to develop sufficient immunity to hepatitis in response to vaccination. Thus different vaccination strategies are needed for children living under conditions of chronic Pb exposure

  2. Hepatic angiography: Portal hypertension

    International Nuclear Information System (INIS)

    Oliver, T.W. Jr.; Sones, P.J. Jr.

    1985-01-01

    Portal hypertension is usually a manifestation of underlying hepatic parenchymal disease, although it may be secondary to portal or hepatic venous thrombosis and rarely to hyperdynamic portal states. Portal hypertension may present as encephalopathy, ascites, jaundice, hepatic failure, or catastrophic upper gastrointestinal hemorrhage. Radiologic investigation should include indirect or direct measurements of portal pressure, assessment of portal venous perfusion, visualization of collaterals, and demonstration of arterial and venous anatomy for potential shunt procedure. Following survival of initial variceal bleeding, the most effective procedure to prevent recurrent hemorrhage is a shunt to decompress the varices. The decision whether to intervene medically or surgically during the acute hemorrhagic episode as well as the type of shunt used to prevent future hemorrhage is the subject of continuing controversy

  3. Heat-washout measurements compared to distal blood pressure and perfusion in orthopaedic patients with foot ulcers

    DEFF Research Database (Denmark)

    Midttun, M; Azad, B B S; Broholm, R

    2015-01-01

    Distal blood pressure and local skin perfusion pressure were compared to measurement of blood flow rate (BFR) measured by the heat-washout method in orthopaedic patients with and without diabetes, all with a foot ulcer in one foot, compared to healthy controls. The correlation was good between heat......-washout and distal blood pressure in patients with diabetes with and without an ulcer (P = 0·024 and 0·059, respectively). The correlation was weak in patients without diabetes with and without an ulcer, most probably due to power problems (P = 0·118 and 0·116, respectively). The correlation in the healthy controls...... the surrounding tissue, and therefore, measurements are easier made in these subjects. BFR in the first toe increased significantly in all patients when the foot was moved from heart level to 50 cm below heart level (P = between 0·03 and 0·05) as previously seen in patients with claudication...

  4. Recombinant immunoblot assay reaction patterns and hepatitis C virus RNA in blood donors and non-A, non-B hepatitis patients

    NARCIS (Netherlands)

    Bresters, D.; Zaaijer, H. L.; Cuypers, H. T.; Reesink, H. W.; Winkel, I. N.; van Exel-Oehlers, P. J.; van Drimmelen, A. A.; Jansen, P. L.; van der Poel, C. L.; Lelie, P. N.

    1993-01-01

    To establish the value of the second-generation recombinant immunoblot assay (RIBA-2) and cDNA polymerase chain reaction (cDNA PCR) for confirmation of hepatitis C virus (HCV) infection, anti-HCV reaction patterns and the presence of HCV RNA were examined in 610 blood donors and 255 non-A, non-B

  5. Characteristics of Brain Perfusion in Patients of Parkinson's Disease

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Park, Min Jung; Kim, Jae Woo; Kang, Young Kang

    2008-01-01

    It was well known that cerebral blood perfusion is normal or diffusely decreased in the majority of patients with Parkinson's disease (PD). Actually we interpreted brain perfusion SPECT images of PD patients in the clinical situation, we observed various cerebral perfusion patterns in patients with PD. So we performed brain perfusion SPECT to know the brain perfusion patterns of PD patients and the difference of perfusion patterns according to the sex and the age. Also we classified PD patients into small groups based on the brain perfusion pattern. Two hundred nineteen patients (M: 70, F: 149, mean age: 62.9±6.9 y/o) who were diagnosed as PD without dementia clinically and 55 patients (M: 15, F: 40, mean age: 61.4±9.2 y/o) as normal controls who had no past illness history were performed 99m Tc-HMPAO brain perfusion SPECT and neuropsychological test. At first, we compared all patients with PD and normal controls. Brain perfusion in left inferior frontal gyrus, left insula, left transverse temporal gyrus, left inferior parietal lobule, left superior parietal lobule, right precuneus, right caudate tail were lower in patients with PD than normal controls. Secondly, we compared male and female patients with PD and normal controls, respectively. Brain perfusion SPECT showed more decreased cerebral perfusion in left hemisphere than right side in both male and female patients compared to normal controls. And there was larger hypoperfusion area in female patients compared with male. Thirdly, we classified patients with PD and normal controls into 4 groups according to the age and compared brain perfusion respectively. In patient below fifties, brain perfusion in both occipitoparietal and left temporal lobe were lower in PD group. As the patients with PD grew older, hypoperfusion area were shown in both frontal, temporal and limbic lobes. Fourthly, We were able to divide patients into small groups based on cerebral perfusion pattern. There was normal cerebral blood

  6. Hepatic natural killer cells exclusively kill splenic/blood natural killer-resistant tumor cells by the perforin/granzyme pathway

    NARCIS (Netherlands)

    Vermijlen, David; Luo, Dianzhong; Froelich, Christopher J.; Medema, Jan Paul; Kummer, Jean Alain; Willems, Erik; Braet, Filip; Wisse, Eddie

    2002-01-01

    Hepatic natural killer (NK) cells are located in the liver sinusoids adherent to the endothelium. Human and rat hepatic NK cells induce cytolysis in tumor cells that are resistant to splenic or blood NK cells. To investigate the mechanism of cell death, we examined the capacity of isolated, pure

  7. CT perfusion scanning of the brain in stroke and beyond

    International Nuclear Information System (INIS)

    Riedel, Christian

    2011-01-01

    CT perfusion scanning (CTP) allows for quantitative analysis of cerebral blood flow (CBF) and cerebral blood volume (CBV). Until recently, it was only possible to study brain perfusion parameters in a small stack of CT-slices close to the skull base. With the introduction of multidetector CT scanners with 64 and more detector rows it has become possible to assess perfusion of the entire brain. An optimal choice of scanning parameters like the new 'shuttle'-technique combined with a well adapted regimen for contrast administration is required to guarantee reliable perfusion measurements while still keeping the X-ray dose absorbed by the patient at a minimum. With these techniques, CTP is not only an important modality in the work-up of patients suffering from acute ischemic stroke but can also be valuable in other emergency situations such as in prolonged epileptic seizures or to monitor patients with subacute subarachnoid hemorrhage. (orig.)

  8. Hepatic apo B-100 lipoproteins and plasma LDL heterogeneity in African green monkeys

    International Nuclear Information System (INIS)

    Murthy, V.N.; Marzetta, C.A.; Rudel, L.L.; Zech, L.A.; Foster, D.M.

    1990-01-01

    The contribution of hepatic apolipoprotein (apo) B-100 lipoproteins to plasma low-density lipoprotein (LDL) metabolic heterogeneity was examined in African green monkeys. Hepatic 3H-labeled very low-density lipoproteins (VLDL) (d less than 1.006, where d is density in g/ml) or hepatic 131I-labeled LDL (1.030 less than d less than 1.063) were isolated from perfused livers and injected simultaneously with autologous plasma 125I-LDL into African green monkeys. Serial blood samples were taken, and the distribution of radioactivity among various subfractions of apo B-100 lipoproteins was determined using density-gradient ultracentrifugation. Compartmental models were developed to describe simultaneously the kinetics of hepatic lipoproteins and plasma LDL. In five of seven studies, the metabolic behavior of LDL derived from radiolabeled hepatic lipoprotein precursors differed from the metabolic behavior of radiolabeled autologous plasma LDL. These differences could be described by different models supporting two hypotheses with different physiological interpretations: (1) lipoproteins of donor and recipient animals are kinetically distinct, and/or (2) plasma LDL derived from various potential sources are kinetically distinct. Compartmental modeling was used to test these hypotheses, which were not accessible to testing by conventional experimental methodologies. The kinetic analyses of these studies suggest that plasma LDL may be derived from a variety of precursors, including hepatic VLDL and hepatic LDL, with each source giving rise to metabolically distinct plasma LDL

  9. Intraportal nicotine infusion in rats decreases hepatic blood flow through endothelin-1 and both endothelin A and endothelin B receptors

    International Nuclear Information System (INIS)

    Hashimoto, Takashi; Yoneda, Masashi; Shimada, Tadahito; Kurosawa, Mieko; Terano, Akira

    2004-01-01

    Smoking has been demonstrated to aggravate liver injury. Nicotine, a major pharmacological component of tobacco smoke, affects a multitude of functions. Smoking and nicotine induce synthesis of endothelin (ET)-1. The effect of intraportal infusion of nicotine on hepatic circulation and an involvement of ET-1 and ET receptor in the action of nicotine were investigated in rats. Nicotine (0-100 μg/kg/h) was infused into the portal vein of urethane-anesthetized rats, and changes of hepatic blood flow were evaluated. Intraportal infusion of nicotine dose-dependently decreased hepatic blood flow and increased portal pressure without any alteration of heart rate or arterial blood pressure. This action of intraportal nicotine was completely abolished by pretreatment of ET-1 antibody. Either BQ485 (ET A receptor antagonist) or BQ788 (ET B receptor antagonist) partially reversed the effect of nicotine, and combination of BQ788 and BQ485 completely abolished it. These findings suggest that nicotine inhibits hepatic circulation through ET-1, and ET A and ET B receptor

  10. Hepatic microvascular dysfunction and increased advanced glycation end products are components of non-alcoholic fatty liver disease.

    Science.gov (United States)

    Pereira, Evelyn Nunes Goulart da Silva; Silvares, Raquel Rangel; Flores, Edgar Eduardo Ilaquita; Rodrigues, Karine Lino; Ramos, Isalira Peroba; da Silva, Igor José; Machado, Marcelo Pelajo; Miranda, Rosiane Aparecida; Pazos-Moura, Carmen Cabanelas; Gonçalves-de-Albuquerque, Cassiano F; Faria-Neto, Hugo Caire de Castro; Tibiriça, Eduardo; Daliry, Anissa

    2017-01-01

    This study aimed to investigate the pathophysiology of hepatic microcirculatory dysfunction in non-alcoholic fatty liver disease (NAFLD). In Wistar rats, NAFLD model was induced by 20 weeks of high-fat diet (HFD) feeding. Rolling and adhesion of leukocytes and tissue perfusion in hepatic microcirculation were examined using in vivo microscopic and laser speckle contrast imaging (LSCI), respectively. Oxidative stress and inflamatory parameters were analysed by TBARs, catalase enzyme activity, RT-PCR and ELISA. The participation of advanced glycation end-products (AGE) and its receptor RAGE was evaluated by the measurement of gene and protein expression of RAGE by RT-PCR and Western-blot, respectively and by liver and serum quantification of fluorescent AGEs. Wistar rats fed high-fat diet (HFD) showed increase in epididymal and abdominal fat content, systolic arterial blood pressure, fasting blood glucose levels, hepatic triglycerides and cholesterol, and impairment of glucose and insulin metabolisms. Liver histology confirmed the presence of steatosis and ultrasound analysis revealed increased liver size and parenchymal echogenicity in HFD-fed rats. HFD causes significant increases in leukocyte rolling and adhesion on hepatic microcirculation and decrease in liver microvascular blood flow. Liver tissue presented increase in oxidative stress and inflammtion. At 20 weeks, there was a significantly increase in AGE content in the liver and serum of HFD-fed rats and an increase in RAGE gene expression in the liver. The increase in liver AGE levels and microcirculatory disturbances could play a role in the pathogenesis of liver injury and are key components of NAFLD.

  11. Evaluation of cerebral perfusion imaging with N-isopropyl-p-[{sup 123}I]iodoamphetamine (IMP) in the cases of antiphospholipid syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Toru; Nanbu, Ichiro; Tohyama, Junko; Ohba, Satoru [Nagoya City Univ. (Japan). Faculty of Medicine

    1995-01-01

    Five cases of antiphospholipid syndrome with mild headache, but without any neurological deficits and abnormal findings by CT and MRI, were examined by cerebral blood perfusion SPECT using N-isopropyl-p-[{sup 123}I] iodoamphetamine (IMP). Although three cases were performed quantification of cerebral blood flow with a microsphere method simultaneously, their values were within normal limits. Two of them showed focal low perfusion areas. One case had relatively low perfusion areas in the bilateral occipital lobes and the right temporal lobe, which improved after treatment. One of two had low perfusion in the bilateral occipital lobes. Other three cases only showed ununiformity of radioisotope uptake on the cerebral blood perfusion SPECT. Low perfusion areas in antiphospholipid syndrome might be caused by microarterial thrombosis, microvenous thrombosis or spasms, although they could be reversible. As early irreversible progress of cerebral blood flow, cerebral blood flow SPECT should be performed in cases of antiphospholipid syndrome with neurological complainments. (author).

  12. Hepatic encephalopathy is associated with decreased cerebral oxygen metabolism and blood flow, not increased ammonia uptake

    DEFF Research Database (Denmark)

    Dam, Gitte; Keiding, Susanne; Munk, Ole Lajord

    2013-01-01

    Studies have shown decreased cerebral oxygen metabolism (CMRO(2)) and blood flow (CBF) in patients with cirrhosis with hepatic encephalopathy (HE). It remains unclear, however, whether these disturbances are associated with HE or with cirrhosis itself and how they may relate to arterial blood...... associated with HE rather than the liver disease as such. The changes in CMRO(2) and CBF could not be linked to blood ammonia concentration or CMRA....

  13. Arterial blood gas management in retrograde cerebral perfusion: the importance of carbon dioxide.

    Science.gov (United States)

    Ueno, K; Takamoto, S; Miyairi, T; Morota, T; Shibata, K; Murakami, A; Kotsuka, Y

    2001-11-01

    Many interventional physiological assessments for retrograde cerebral perfusion (RCP) have been explored. However, the appropriate arterial gas management of carbon dioxide (CO2) remains controversial. The aim of this study is to determine whether alpha-stat or pH-stat could be used for effective brain protection under RCP in terms of cortical cerebral blood flow (CBF), cerebral metabolic rate for oxygen (CMRO2), and distribution of regional cerebral blood flow. Fifteen anesthetized dogs (25.1+/-1.1 kg) on cardiopulmonary bypass (CPB) were cooled to 18 degrees C under alpha-stat management and had RCP for 90 min under: (1), alpha-stat; (2), pH-stat; or (3), deep hypothermic (18 degrees C) antegrade CPB (antegrade). RCP flow was regulated for a sagittal sinus pressure of around 25 mmHg. CBF was monitored by a laser tissue flowmeter. Serial analyses of blood gas were made. The regional cerebral blood flow was measured with colored microspheres before discontinuation of RCP. CBF and CMRO2 were evaluated as the percentage of the baseline level (%CBF, %CMRO2). The oxygen content of arterial inflow and oxygen extraction was not significantly different between the RCP groups. The %CBF and %CMRO2 were significantly higher for pH-stat RCP than for alpha-stat RCP. The regional cerebral blood flow, measured with colored microspheres, tended to be higher for pH-stat RCP than for alpha-stat RCP, at every site in the brain. Irrespective of CO2 management, regional differences were not significant among any site in the brain. CO2 management is crucial for brain protection under deep hypothermic RCP. This study revealed that pH-stat was considered to be better than alpha-stat in terms of CBF and oxygen metabolism in the brain. The regional blood flow distribution was considered to be unchanged irrespective of CO2 management.

  14. Comparison between acoustic radiation force impulse quantification data and perfusion-CT parameters in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Esser, Michael, E-mail: michael.esser@med.uni-tuebingen.de; Schneeweiß, Sven, E-mail: sven.schneeweiss@med.uni-tuebingen.de; Kolb, Manuel, E-mail: manuel.kolb@med.uni-tuebingen.de; Kurucay, Mustafa, E-mail: mustafa.kurucay@med.uni-tuebingen.de; Ruff, Christer, E-mail: christer.ruff@med.uni-tuebingen.de; Nikolaou, Konstantin, E-mail: konstantin.nikolaou@med.uni-tuebingen.de; Horger, Marius, E-mail: marius.horger@med.uni-tuebingen.de

    2017-04-15

    Highlights: • HCC tissue stiffness did not correlate with the degree of tumor vascularization. • HCC tissue stiffness declined while increasing HCC distance to the skin surface. • HCC tissue stiffness showed higher values the larger the respective tumor was. • Poorly differentiated HCCs showed increased values of tumor tissue stiffness. - Abstract: Objective: To find out, if ultrasound elastography of hepatocellular carcinoma (HCC) can predict patterns of tumor perfusion in volume perfusion computed tomography (VPCT). Material and methods: 25 consecutive patients (mean age, 68.9; range, 51–85 years) with liver cirrhosis suspected of HCC underwent VPCT and acoustic radiation force impulse (ARFI) elastography the same day. Quantitative elasticity values were registered, while blood flow (BF), blood volume (BV) and hepatic perfusion index (HPI) of the HCC lesions were calculated. Additionally, we identified histologic WHO grading, lesion size and localization. The Siemens Acuson S 3000 HELX-System with Virtual Touch™-Software and Siemens Somatom Definition Flash with Syngo{sup ®} software were used. Results: A total of 43 HCC lesions were assessed. Mean shear wave velocity was 2.6 m/s (range, 1.1–4.3 m/s). There was no significant linear correlation between the elasticity values and BF (p = 0.751), BV (p = 0.426) and HPI (p = 0.437). However, elasticity values were higher, the larger the tumor was (p = 0.008). Shear wave velocity declined with increasing distance of the HCC to the skin surface (p = 0.028) and depending on liver segment. In addition, elasticity values were higher in less differentiated HCCs. This trend was not statistically significant (p = 0.842). Conclusion: Tissue elasticity in HCC does not correlate with the degree of tumor vascularization, but calculated values are influenced both by the tumor size and localization inside the liver.

  15. Visceral perfusion abnormalities following complement activation. Clues to the mediators of organ ischemia in trauma and sepsis. First place winner: Conrad Jobst Award.

    Science.gov (United States)

    Schirmer, W J; Schirmer, J M; Naff, G B; Fry, D E

    1988-12-01

    Complement, activated during infection and injury, has been implicated as a mediator of microvascular injury and obstruction. This study examines how two potent activators of complement, zymosan, and cobra venom factor (CVF), affect systemic and visceral perfusion. Rats were injected with either saline (1 ml/kg), zymosan (5 mg/kg) or CVF (5 units/kg) at t = 0 and 30 minutes. Thermodilution cardiac output, mean arterial pressure, heart rate, systemic vascular resistance, and hematocrit were determined at t = 2 hours. Effective hepatic and renal blood flows, by clearance of galactose and p-aminohippurate respectively, were determined over the next hour. The per cent change in total hemolytic complement from t = 0 to t = 3 hours was determined by immune hemolysis of sheep erythrocytes. There was no difference in systemic hemodynamic parameters between the three groups. Hepatic blood flow was depressed in both the zymosan (3.83 +/- 0.23 ml/min/100 g) and CVF (3.72 +/- 0.20 ml/min/100 g) groups compared with controls (4.62 +/- 0.19 ml/min/100 g, P less than 0.05). Renal blood flow in the zymosan-treated group (6.40 +/- 0.24 ml/min/100 g) increased over control (4.80 +/- 0.40 ml/min/100 g, P less than 0.05) but was unchanged in the CVF group (5.06 +/- 0.23 ml/min/100 g). The amount of complement activated correlated with the change in hepatic (r = -0.419, P less than 0.05) but not renal (r = -0.008, P = 0.917) flow. Complement activation may occupy a proximal position in the pathogenesis of hepatic ischemia associated with trauma and sepsis.

  16. Relationship among blood indicators of lipomobilization and hepatic function during early lactation in high-yielding dairy cows.

    Science.gov (United States)

    González, Felix Diaz; Muiño, Rodrigo; Pereira, Víctor; Campos, Rómulo; Benedito, José Luis

    2011-09-01

    Blood indicators are used as a tool to diagnose metabolic disorders. The present work was conducted to study the relationships among blood indicators of lipomobilization and hepatic function in high-yielding dairy cows. Two groups of Holstein cows were studied: 27 early lactation cows and 14 mid lactation cows from four different herds with similar husbandry characteristics in Galicia, Spain. Blood samples were obtained to measure beta-hydroxybutyrate (BHB), non-esterified fatty acids (NEFA), triglycerides (TG), and the activity of aspartate transaminase (AST) and gamma-glutamyl transferase. Cows in early lactation had higher levels of BHB and NEFA than mid lactation cows. High lipomobilization (NEFA > 400 µmol/L) was detected in 67% and 7% of early lactation and mid lactation cows, respectively, while subclinical ketosis (BHB > 1.2 mmol/L) was detected in 41% and 28% of the early lactation and lactation cows, respectively. TG concentrations were low in all cows suffering subclinical ketosis and in 61% of the cows with high lipomobilization. During early lactation, 30% of cows suffered hepatic lipidosis as detected by levels of AST. Compromised hepatic function was observed in early lactation cows as shown by lower concentrations of glucose, total protein, and urea.

  17. Repeatability of Bolus Kinetics Ultrasound Perfusion Imaging for the Quantification of Cerebral Blood Flow

    NARCIS (Netherlands)

    Vinke, Elisabeth J.; Eyding, Jens; de Korte, Chris L.; Slump, Cornelis H.; van der Hoeven, Johannes G.; Hoedemaekers, Cornelia W.E.

    2017-01-01

    Ultrasound perfusion imaging (UPI) can be used for the quantification of cerebral perfusion. In a neuro-intensive care setting, repeated measurements are required to evaluate changes in cerebral perfusion and monitor therapy. The aim of this study was to determine the repeatability of UPI in

  18. EFFECT OF ETHANOL ON HEPATOBILIARY TRANSPORT OF CATIONIC DRUGS - A STUDY IN THE ISOLATED-PERFUSED RAT-LIVER, RAT HEPATOCYTES AND RAT MITOCHONDRIA

    NARCIS (Netherlands)

    STEEN, H; MEIJER, DKF; Merema, M.T.

    The effect of ethanol on the hepatic uptake of various cationic drugs was studied in isolated perfused rat livers, isolated rat hepatocytes and isolated rat liver mitochondria. In isolated rat hepatocytes and in isolated perfused rat livers, the uptake of the model organic cation

  19. Comparison of risk factors among blood donors, volunteers and replacement individuals, infected or not by hepatitis C virus

    Directory of Open Access Journals (Sweden)

    MJDB Felippe

    2009-01-01

    Full Text Available Hepatitis C is transmitted primarily parenterally by contaminated blood and is often associated with: intravenous drug abuse, invasive procedures, blood transfusions, acupuncture, tattooing, and alcohol and tobacco use. This study aimed to quantify and evaluate the risk factors among blood donors, volunteer blood donors and replacement individuals, infected or not by the C virus. The main transmission routes of C virus were identified in 55 men and 25 women (GI monitored by the Ambulatory Unit of the Department of Tropical Diseases, Botucatu Medical School, and in 24 men and 26 women (GII, all active blood donors at the Bauru State Hospital Transfusional Agency. Both groups were similar in: tobacco and alcohol consumption, sexual behavior, tattooing and illicit drug use. The duration of alcohol and tobacco consumption and blood transfusions in GI were longer, whereas the option for steady partners, condom use, disposable materials and piercings were predominant in GII. In conclusion, the risk factors for hepatitis C demonstrate the necessity of health policies that act on the primary and secondary prevention levels (respectively, reduction of infection incidence and hepatopathy risk.

  20. DNA double-strand breaks in blood lymphocytes induced by two-day 99mTc-MIBI myocardial perfusion scintigraphy.

    Science.gov (United States)

    Rief, Matthias; Hartmann, Lisa; Geisel, Dominik; Richter, Felicitas; Brenner, Winfried; Dewey, Marc

    2018-07-01

    To investigate DNA double-strand breaks (DSBs) in blood lymphocytes induced by two-day 99m Tc-MIBI myocardial perfusion scintigraphy (MPS) using y-H2AX immunofluorescence microscopy and to correlate the results with 99m Tc activity in blood samples. Eleven patients who underwent two-day MPS were included. DSB blood sampling was performed before and 5min, 1h and 24h after the first and second radiotracer injections. 99m Tc activity was measured in each blood sample. For immunofluorescence microscopy, distinct foci representing DSBs were quantified in lymphocytes after staining for the phosphorylated histone variant y-H2AX. The 99m Tc-MIBI activity measured on days one and two was similar (254±25 and 258±27 MBq; p=0.594). Compared with baseline DSB foci (0.09±0.05/cell), a significant increase was found at 5min (0.19±0.04/cell) and 1h (0.18±0.04/cell) after the first injection and at 5min and 1h after the second injection (0.21±0.03 and 0.19±0.04/cell, respectively; p=0.003 for both). At 24h after the first and second injections, the number of DSB foci had returned to baseline (0.06±0.02 and 0.12±0.05/cell, respectively). 99m Tc activity levels in peripheral blood samples correlated well with DSB counts (r=0.451). DSB counts reflect 99m Tc-MIBI activity after injection for two-day MPS, and might allow individual monitoring of biological effects of cardiac nuclear imaging. • Myocardial perfusion scintigraphy using 99m Tc induces time-dependent double-strand breaks (DSBs) • γ-H2AX immunofluorescence microscopy shows DSB as an early response to radiotracer injection • Activity measurements of 99m Tc correlate well with detected DSB • DSB foci induced by 99m Tc return to baseline 24h after radiotracer injection.

  1. In vivo MR perfusion imaging of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.; Lorenz, C.H.; Bain, R.; Holburn, G.; Price, R.R.

    1989-01-01

    Various techniques have been developed for noninvasive evaluation of renal blood flow. More important in the assessment of potential renal ischemia may be actual perfusion of the nephron mass. MR pulse sequences have been devised that allow perfusion imaging (PI) in a dog model of renal artery stenosis. Unilateral renal artery stenosis was created in mongrel dogs and quantitation of renal blood flow was obtained with radioactive microspheres. Perfusion imaging was performed on a 1.5-T system to obtain the apparent diffusion coefficient. During initial studies, it was found that the usual gradient factor used in brain PI was too high for renal studies; a factor of < 50 was found to be optimal. Additionally, respiratory gating with acquisition at end expiration was necessary to prevent renal motion. Recent studies have shown that PI reflects the asymmetry of flow in this model

  2. Feasibility of ASL spinal bone marrow perfusion imaging with optimized inversion time.

    Science.gov (United States)

    Xing, Dong; Zha, Yunfei; Yan, Liyong; Wang, Kejun; Gong, Wei; Lin, Hui

    2015-11-01

    To assess the correlation between flow-sensitive alternating inversion recovery (FAIR) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in the measurement of spinal bone marrow (SBM) perfusion; in addition, to assess for an optimized inversion time (TI) as well as the reproducibility of SBM FAIR perfusion. The optimized TI of a FAIR SBM perfusion experiment was carried out on 14 volunteers; two adjacent vertebral bodies were selected from each volunteer to measure the change of signal intensity (ΔM) and the signal-to-noise ratio (SNR) of FAIR perfusion MRI with five different TIs. Then, reproducibility of FAIR data from 10 volunteers was assessed by the reposition SBM FAIR experiments. Finally, FAIR and DCE-MRI were performed on 27 subjects. The correlation between the blood flow on FAIR (BFASL ) and perfusion-related parameters on DCE-MRI was evaluated. The maximum value of ΔM and SNR were 36.39 ± 12.53 and 2.38 ± 0.97, respectively; both were obtained when TI was near 1200 msec. There were no significant difference between the two successive measurements of SBM BFASL perfusion (P = 0.879), and the within-subject coefficients of variation (wCV) of the measurements was 3.28%. The BFASL showed a close correlation with K(trans) (P FAIR perfusion scan protocol has good reproducibility, and as blood flow measurement on FAIR is reliable and closely related with the parameters on DCE-MRI, FAIR is feasible for measuring SBM blood flow. © 2015 Wiley Periodicals, Inc.

  3. Modeling laser speckle imaging of perfusion in the skin (Conference Presentation)

    Science.gov (United States)

    Regan, Caitlin; Hayakawa, Carole K.; Choi, Bernard

    2016-02-01

    Laser speckle imaging (LSI) enables visualization of relative blood flow and perfusion in the skin. It is frequently applied to monitor treatment of vascular malformations such as port wine stain birthmarks, and measure changes in perfusion due to peripheral vascular disease. We developed a computational Monte Carlo simulation of laser speckle contrast imaging to quantify how tissue optical properties, blood vessel depths and speeds, and tissue perfusion affect speckle contrast values originating from coherent excitation. The simulated tissue geometry consisted of multiple layers to simulate the skin, or incorporated an inclusion such as a vessel or tumor at different depths. Our simulation used a 30x30mm uniform flat light source to optically excite the region of interest in our sample to better mimic wide-field imaging. We used our model to simulate how dynamically scattered photons from a buried blood vessel affect speckle contrast at different lateral distances (0-1mm) away from the vessel, and how these speckle contrast changes vary with depth (0-1mm) and flow speed (0-10mm/s). We applied the model to simulate perfusion in the skin, and observed how different optical properties, such as epidermal melanin concentration (1%-50%) affected speckle contrast. We simulated perfusion during a systolic forearm occlusion and found that contrast decreased by 35% (exposure time = 10ms). Monte Carlo simulations of laser speckle contrast give us a tool to quantify what regions of the skin are probed with laser speckle imaging, and measure how the tissue optical properties and blood flow affect the resulting images.

  4. RECENT THEORIES OF PATHOGENESIS OF HEPATIC ENCEPHALOPATHY IN HEPATITIS C VIRAL INFECTION

    Directory of Open Access Journals (Sweden)

    Lidija Popović Dragonjić

    2013-01-01

    Full Text Available Hepatic encephalopathy is potentially reversible, or progressive neuropsychiatric syndrome characterized by changes in cognitive function, behavior and personality changes, and transient neurologic symptoms and characteristic electroencephalographic patterns associated with acute and chronic liver failure. For some time, there has been controversy regarding the origin of toxins responsible for the change of mental state. It was found that the occurrence of hepatic encephalopathy is responsible for multiple organ peripheral changes (intestinal changes, abnormalities of portal-systemic circulation, liver failure, loss of muscle tissue, changes in brain intracellular communication (osmotic changes, astrocytes and axonal abnormalities in communication, changes in cerebral perfusion and ammonia, endogenous benzodiazepines, gamma amino butyric acid, derivatives of methionine and false neurotransmitters. The aforementioned metabolic factors that contribute to the development of hepatic encephalopathy are not mutually exclusive and multiple factors may be present at the same time.

  5. Hepatic Differentiation of Human Induced Pluripotent Stem Cells in a Perfused 3D Porous Polymer Scaffold for Liver Tissue Engineering

    DEFF Research Database (Denmark)

    Hemmingsen, Mette; Muhammad, Haseena Bashir; Mohanty, Soumyaranjan

    A huge shortage of liver organs for transplantation has motivated the research field of tissue engineering to develop bioartificial liver tissue and even a whole liver. The goal of NanoBio4Trans is to create a vascularized bioartificial liver tissue, initially as a liver-support system. Due...... to limitations of primary hepatocytes regarding availability and maintenance of functionality, stem cells and especially human induced pluripotent stem cells (hIPS cells) are an attractive cell source for liver tissue engineering. The aim of this part of NanoBio4Trans is to optimize culture and hepatic...... differentiation of hIPS-derived definitive endoderm (DE) cells in a 3D porous polymer scaffold built-in a perfusable bioreactor. The use of a microfluidic bioreactor array enables the culture of 16 independent tissues in one experimental run and thereby an optimization study to be performed....

  6. Transient hepatic attenuation differences in neonates

    International Nuclear Information System (INIS)

    Towbin, Alexander J.; Fleck, Robert; Ying, Jun

    2009-01-01

    A transient hepatic attenuation difference (THAD) is a hepatic perfusion anomaly seen on contrast-enhanced CT scans caused by an alteration in the dual blood supply of the liver. Although THADs have been described in adolescents and adults, they have not previously been described in neonates. We describe the appearance and evaluate the frequency of THADs in neonates ≤1 month of age compared to other infants younger than 2 years. A retrospective study was performed looking at all CT angiograms from 2000 to 2007 in infants <2 years of age. The incidence of THADs was compared among four age groups. Significance was determined using a logistic regression model. The study included 128 CT angiograms. A THAD was seen in 9/26 infants <1 month of age, in 3/50 infants 1 to 6 months of age, in 1/23 infants 6 months to 1 year of age, and in 1/29 infants 1 to 2 years of age. A THAD was found significantly more frequently in infants <1 month of age than in the older age groups (P<0.05). THADs are benign entities that can be seen normally in the neonatal age group. When the characteristic appearance is seen on CT, no further imaging is needed. (orig.)

  7. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  8. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  9. A multicentre molecular analysis of hepatitis B and blood-borne virus coinfections in Viet Nam.

    Science.gov (United States)

    Dunford, Linda; Carr, Michael J; Dean, Jonathan; Nguyen, Linh Thuy; Ta Thi, Thu Hong; Nguyen, Binh Thanh; Connell, Jeff; Coughlan, Suzie; Nguyen, Hien Tran; Hall, William W; Thi, Lan Anh Nguyen

    2012-01-01

    Hepatitis B (HBV) infection is endemic in Viet Nam, with up to 8.4 million individuals estimated to be chronically infected. We describe results of a large, multicentre seroepidemiological and molecular study of the prevalence of HBV infection and blood-borne viral coinfections in Viet Nam. Individuals with varying risk factors for infection (n = 8654) were recruited from five centres; Ha Noi, Hai Phong, Da Nang, Khanh Hoa and Can Tho. A mean prevalence rate of 10.7% was observed and levels of HBsAg were significantly higher in injecting drug users (IDUs) (17.4%, n = 174/1000) and dialysis patients (14.3%, n = 82/575) than in lower-risk groups (9.4%; pViet Nam and also highlights the significant levels of blood-borne virus coinfections, which have important implications for hepatitis-related morbidity and development of effective management strategies.

  10. Hepatitis C genotype distribution in patient and blood donor samples in South Africa for the period 2008-2012.

    Science.gov (United States)

    Prabdial-Sing, N; Chirwa, T; Thaver, J; Smuts, H; Vermeulen, M; Suchard, M; Puren, A J

    2016-11-01

    There are limited molecular epidemiological studies of hepatitis C at a national level in South Africa. The introduction of newer treatment modalities for hepatitis C requires knowledge of the genotypes as these may have different prognostic and therapeutic implications. This retrospective study describes genotype distributions of patients attending specialist clinics and a blood donor group studied during the period 2008-2012 in South Africa. Residual samples from diagnostic viral load testing from specialist clinics in South Africa (n=941) and from the South African National Blood Service (n=294) were analysed quantitatively by real-time PCR and genotyped using the Versant line probe assay or sequencing. Genotype 1 was predominant in blood donors (34%), whilst genotype 5a was prevalent in patients (36%). In the blood donor group, genotype 4 was detected for the first time. Genotype 2 was rare in the patient group and not detected in blood donors. Genotype 1 was the predominant genotype in the younger age groups (less than 30 years), whereas genotype 5a was found at higher proportions in the older age groups for both the patient and blood donor groups, comprising more than 60% of genotypes in those older than 50 years. Genotypes 1 and 5 were at highest proportions across all provinces compared to other genotypes. In blood donors, genotype 1 was predominant among Caucasians (43%) and genotype 5a among Blacks (54%). Such information is required for planning the impact on the health sector with regard to newly emerging therapies for hepatitis C and burden of disease. © 2016 John Wiley & Sons Ltd.

  11. Effect of perfusion and irrigation flow rate variations on NaCl efflux from the isolated, perfused head of the marine teleost, Myoxocephalus octodecimspinosus

    Energy Technology Data Exchange (ETDEWEB)

    Claiborne, J.B. (Miami Univ., Coral Gables, FL (USA)); Evans, D.H. (Mt. Desert Island Biological Laboratory, Salsbury Cove, ME, USA)

    1981-06-01

    In vivo branchial blood pressure and unidirectional efflux values for NaCl were determined in the marine teleost, Myoxocephalus octodecimspinosus. Utilizing an isolated, perfused head preparation, perfused at in vivo pressure levels, NaCl efflux was measured and compared to in vivo values. The effect of variations in perfusion or irrigation rates on the ion efflux across the gills of the isolated head was also studied. The efflux of /sup 22/Na from the isolated, perfused head was found to be similar to in vivo values and dependent on perfusion flow and pressure. In vitro /sup 36/Cl efflux was lower than the efflux from intact animals and was determined to be flow/pressure independent. Irrigation rate changes at all rates tested did not affect the unidirectional efflux of either ion.

  12. 13C Mrs Studies of the Control of Hepatic Glycogen Metabolism at High Magnetic Fields

    Science.gov (United States)

    Miller, Corin O.; Cao, Jin; Zhu, He; Chen, Li M.; Wilson, George; Kennan, Richard; Gore, John C.

    2017-06-01

    Introduction: Glycogen is the primary intracellular storage form of carbohydrates. In contrast to most tissues where stored glycogen can only supply the local tissue with energy, hepatic glycogen is mobilized and released into the blood to maintain appropriate circulating glucose levels, and is delivered to other tissues as glucose in response to energetic demands. Insulin and glucagon, two current targets of high interest in the pharmaceutical industry, are well known glucose-regulating hormones whose primary effect in liver is to modulate glycogen synthesis and breakdown. The purpose of these studies was to develop methods to measure glycogen metabolism in real time non-invasively both in isolated mouse livers, and in non-human primates (NHPs) using 13C MRS. Methods: Livers were harvested from C57/Bl6 mice and perfused with [1-13C] Glucose. To demonstrate the ability to measure acute changes in glycogen metabolism ex-vivo, fructose, glucagon, and insulin were administered to the liver ex-vivo. The C1 resonance of glycogen was measured in real time with 13C MRS using an 11.7T (500 MHz) NMR spectrometer. To demonstrate the translatability of this approach, NHPs (male rhesus monkeys) were studied in a 7 T Philips MRI using a partial volume 1H/13C imaging coil. NPHs were subjected to a variable IV infusion of [1-13C] glucose (to maintain blood glucose at 3-4x basal), along with a constant 1 mg/kg/min infusion of fructose. The C1 resonance of glycogen was again measured in real time with 13C MRS. To demonstrate the ability to measure changes in glycogen metabolism in vivo, animals received a glucagon infusion (1 μg/kg bolus followed by 40 ng/kg/min constant infusion) half way through the study on the second study session. Results: In both perfused mouse livers and in NHPs, hepatic 13C-glycogen synthesis (i.e. monotonic increases in the 13C-glycogen NMR signal) was readily detected. In both paradigms, addition of glucagon resulted in cessation of glycogen synthesis

  13. [Comparison of the effects of the intervention with electric thermal bian stone and air suction cup on blood perfusion at meridian points].

    Science.gov (United States)

    Zhao, Pengna; Wang, Yanping; Gu, Feifei; Li, Chaozheng; Wei, Yulong; Wang, Guangjun; Zhang, Weibo

    2018-02-12

    To observe the impacts of the intervention with electric thermal bian stone and air suction cup on blood perfusion (BP) at meridian points and explore the approach of accurate measurement and regulation of meridian qi and blood balance in "precise acupuncture". The laser Doppler line scanner (LDLS) was used to measure BP at bilateral yua n-primary points at the pericardium meridian, the triple energizer meridian, the gallbladder meridian and the liver meridian (small cycle of jueyin to shaoyang meridians) at 31 healthy receptors. The bias ratio of blood perfusion (BPBR) deviated to the reference value was calculated. The electric thermal bian stone and air suction cup were used in the intervention at the he -sea points of the affected meridians in which BPBR was relatively higher at the yuan -primary points. The electric thermal bian stone therapy was used when BPBR was less than -30% and the air suction cupping therapy was used when BPBR was higher than 30%. BP was measured twice before intervention and it was measured separately at the moment after intervention and in 20 min after intervention. The means of BP before and after intervention and the change ratio of blood perfusion (BPCR) before intervention, at the moment after intervention and 20 min after intervention were calculated. 1. After the intervention of electric thermal bian stone, BP mean was increased from (103.51±41.21) PU to (121.97±56.22) PU ( P 0.05), but the change ratio was highly remained. 2. After intervention with air suction cup, BP mean was reduced from (194.83±81.14) PU to (173.88±88.26) PU. Before intervention, at the moment after intervention and 20 min after intervention, separately, BPCR were (7.62±30.49)%, (-12.12±18.20)% and (-14.35±21.25)%. BPCR at the moment after intervention and in 20 min after intervention were significantly different from that before intervention (both P cup is opposite.

  14. Pathogenesis of Hepatic Encephalopathy

    Directory of Open Access Journals (Sweden)

    Irena Ciećko-Michalska

    2012-01-01

    Full Text Available Hepatic encephalopathy can be a serious complication of acute liver failure and chronic liver diseases, predominantly liver cirrhosis. Hyperammonemia plays the most important role in the pathogenesis of hepatic encephalopathy. The brain-blood barrier disturbances, changes in neurotransmission, neuroinflammation, oxidative stress, GABA-ergic or benzodiazepine pathway abnormalities, manganese neurotoxicity, brain energetic disturbances, and brain blood flow abnormalities are considered to be involved in the development of hepatic encephalopathy. The influence of small intestine bacterial overgrowth (SIBO on the induction of minimal hepatic encephalopathy is recently emphasized. The aim of this paper is to present the current views on the pathogenesis of hepatic encephalopathy.

  15. Pathogenesis of Hepatic Encephalopathy

    Science.gov (United States)

    Ciećko-Michalska, Irena; Szczepanek, Małgorzata; Słowik, Agnieszka; Mach, Tomasz

    2012-01-01

    Hepatic encephalopathy can be a serious complication of acute liver failure and chronic liver diseases, predominantly liver cirrhosis. Hyperammonemia plays the most important role in the pathogenesis of hepatic encephalopathy. The brain-blood barrier disturbances, changes in neurotransmission, neuroinflammation, oxidative stress, GABA-ergic or benzodiazepine pathway abnormalities, manganese neurotoxicity, brain energetic disturbances, and brain blood flow abnormalities are considered to be involved in the development of hepatic encephalopathy. The influence of small intestine bacterial overgrowth (SIBO) on the induction of minimal hepatic encephalopathy is recently emphasized. The aim of this paper is to present the current views on the pathogenesis of hepatic encephalopathy. PMID:23316223

  16. Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?

    Science.gov (United States)

    Mulé, Sébastien; Pigneur, Frédéric; Quelever, Ronan; Tenenhaus, Arthur; Baranes, Laurence; Richard, Philippe; Tacher, Vania; Herin, Edouard; Pasquier, Hugo; Ronot, Maxime; Rahmouni, Alain; Vilgrain, Valérie; Luciani, Alain

    2018-05-01

    To determine the degree of relationship between iodine concentrations derived from dual-energy CT (DECT) and perfusion CT parameters in patients with advanced HCC under treatment. In this single-centre IRB approved study, 16 patients with advanced HCC treated with sorafenib or radioembolization who underwent concurrent dynamic perfusion CT and multiphase DECT using a single source, fast kV switching DECT scanner were included. Written informed consent was obtained for all patients. HCC late-arterial and portal iodine concentrations, blood flow (BF)-related and blood volume (BV)-related perfusion parameters maps were calculated. Mixed-effects models of the relationship between iodine concentrations and perfusion parameters were computed. An adjusted p value (Bonferroni method) statistic (F)=28.52, padvanced HCC lesions, DECT-derived late-arterial iodine concentration is strongly related to both aBF and BV, while portal iodine concentration mainly reflects BV, offering DECT the ability to evaluate both morphological and perfusion changes. • Late-arterial iodine concentration is highly related to arterial BF and BV. • Portal iodine concentration mainly reflects tumour blood volume. • Dual-energy CT offers significantly decreased radiation dose compared with perfusion CT.

  17. Role of dynamic CT perfusion study in evaluating various intracranial space-occupying lesions

    International Nuclear Information System (INIS)

    Kamble, Ravindra B; Jayakumar, Peruvumba N; Shivashankar, Ravishankar

    2015-01-01

    Differentiating intracranial mass lesions on CT scan is challenging. The purpose of our study was to determine the perfusion parameters in various intracranial space-occupying lesions (ICSOL), differentiate benign and malignant lesions, and differentiate between grades of gliomas. We performed CT perfusion (CTP) in 64 patients, with age ranging from 17 to 68 years, having space-occupying lesions in brain and calculated relative cerebral blood flow (rCBF) and relative cerebral blood volume (rCBV). We found significantly lower perfusion in low-grade gliomas as compared to high-grade tumors, lymphoma, and metastases. Similarly in infective lesions, TWT and abscesses showed significantly lower perfusion compared to TOT. In ring enhancing lesions, capsule of TWT showed significantly lower perfusion as compared to abscesses, TOT, and metastases. Thus, in conclusion, infective lesions can be differentiated from tumors like lymphomas, high-grade gliomas, or metastases based on perfusion parameters. The cut off value of rCBV 1.64 can be used to differentiate between low grade and high grade gliomas. However, depending only on perfusion parameters, differentiation between the tumors like lymphomas, high-grade gliomas, and metastases may not be possible

  18. Role of dynamic CT perfusion study in evaluating various intracranial space-occupying lesions

    Directory of Open Access Journals (Sweden)

    Ravindra B Kamble

    2015-01-01

    Full Text Available Aims: Differentiating intracranial mass lesions on CT scan is challenging. The purpose of our study was to determine the perfusion parameters in various intracranial space-occupying lesions (ICSOL, differentiate benign and malignant lesions, and differentiate between grades of gliomas. Materials and Methods: We performed CT perfusion (CTP in 64 patients, with age ranging from 17 to 68 years, having space-occupying lesions in brain and calculated relative cerebral blood flow (rCBF and relative cerebral blood volume (rCBV. Results: We found significantly lower perfusion in low-grade gliomas as compared to high-grade tumors, lymphoma, and metastases. Similarly in infective lesions, TWT and abscesses showed significantly lower perfusion compared to TOT. In ring enhancing lesions, capsule of TWT showed significantly lower perfusion as compared to abscesses, TOT, and metastases. Conclusion: Thus, in conclusion, infective lesions can be differentiated from tumors like lymphomas, high-grade gliomas, or metastases based on perfusion parameters. The cut off value of rCBV 1.64 can be used to differentiate between low grade and high grade gliomas. However, depending only on perfusion parameters, differentiation between the tumors like lymphomas, high-grade gliomas, and metastases may not be possible.

  19. Results of a Randomized Controlled Multicenter Phase III Trial of Percutaneous Hepatic Perfusion Compared with Best Available Care for Patients with Melanoma Liver Metastases.

    Science.gov (United States)

    Hughes, Marybeth S; Zager, Jonathan; Faries, Mark; Alexander, H Richard; Royal, Richard E; Wood, Bradford; Choi, Junsung; McCluskey, Kevin; Whitman, Eric; Agarwala, Sanjiv; Siskin, Gary; Nutting, Charles; Toomey, Mary Ann; Webb, Carole; Beresnev, Tatiana; Pingpank, James F

    2016-04-01

    There is no consensus for the treatment of melanoma metastatic to the liver. Percutaneous hepatic perfusion with melphalan (PHP-Mel) is a method of delivering regional chemotherapy selectively to the liver. In this study, we report the results of a multicenter, randomized controlled trial comparing PHP-Mel with best alternative care (BAC) for patients with ocular or cutaneous melanoma metastatic to the liver. A total of 93 patients were randomized to PHP-Mel (n = 44) or BAC (n = 49). On the PHP-Mel arm, melphalan was delivered via the hepatic artery, and the hepatic effluent captured and filtered extracorporeally prior to return to the systemic circulation via a venovenous bypass circuit. PHP-Mel was repeatable every 4-8 weeks. The primary endpoint was hepatic progression-free survival (hPFS), and secondary endpoints included overall PFS (oPFS), overall survival (OS), hepatic objective response (hOR), and safety. hPFS was 7.0 months for PHP-Mel and 1.6 months for BAC (p PHP-Mel and 1.6 months for BAC (p PHP-Mel 10.6 months vs. BAC 10.0 months), likely due to crossover to PHP-Mel treatment (57.1 %) from the BAC arm, and the hOR was 36.4 % for PHP-Mel and 2.0 % for BAC (p PHP-Mel, three in the primary PHP-Mel group, and one post-crossover to PHP-Mel from BAC. This randomized, phase III study demonstrated the efficacy of the PHP-Mel procedure. hPFS, oPFS, and hOR were significantly improved with PHP-Mel. PHP with melphalan should provide a new treatment option for unresectable metastatic melanoma in the liver.

  20. Time trend of the prevalence of hepatitis E antibodies among farmers and blood donors: a potential zoonosis in Denmark

    DEFF Research Database (Denmark)

    Christensen, Peer B; Engle, Ronald E; Hjort, Charlotte

    2008-01-01

    BACKGROUND: Antibody to hepatitis E virus (anti-HEV) is prevalent in Western countries, where clinical hepatitis E is rarely reported. The aim of this study was to determine the prevalence of anti-HEV among Danish blood donors and Danish farmers. In addition, we compared the prevalence among 2 sets...... groups (P hepatitis A virus were associated with the presence of anti-HEV in multivariate analysis. Among farmers, only age was independently associated with the presence of anti...

  1. Correlations between skin blood perfusion values and nailfold capillaroscopy scores in systemic sclerosis patients.

    Science.gov (United States)

    Ruaro, B; Sulli, A; Pizzorni, C; Paolino, S; Smith, V; Cutolo, M

    2016-05-01

    To correlate blood perfusion (BP) values assessed by laser speckle contrast analysis (LASCA) in selected skin areas of hands and face with nailfold capillary damage scores in systemic sclerosis (SSc) patients. Seventy SSc patients (mean SSc duration 6 ± 5 years) and 70 volunteer healthy subjects were enrolled after informed consent. LASCA was performed at different areas of the face (forehead, tip of nose, zygomas and perioral region) and at dorsal and volar regions of hands. Microvascular damage was assessed and scored by nailfold videocapillaroscopy (NVC) and the microangiopathy evolution score (MES) was calculated. SSc patients showed a significantly lower BP than healthy subjects at fingertips, periungual areas and palm of hands (pnailfold capillaroscopy scores of microangiopathy. Copyright © 2016. Published by Elsevier Inc.

  2. [THE STATE OF HEPATIC AND SPLANCHNIC BLOOD FLOW IN VARIOUS TYPES OF COMPLICATED PANCREATIC PSEUDOCYSTS].

    Science.gov (United States)

    Kryvoruchko, I A; Goncharova, N M; Andreyeshchev, S A; Yavorska, T P

    2015-05-01

    Investigations were conducted in 37 patients, suffering complicated pancreatic pseudocysts. In accordance to data of ultrasound Doppler flowmetry for the blood flow along portal vein, a. hepatis communis, a. mesenterica superior in complicated pancreatic pseudocysts compensatory--adaptive reactions on level of hepatic--spanchnic blood flow are directed towards restriction of the blood inflow through the portal vein system. This is accompanied by the common peripheral vascular resistence raising in basin of a. mesenterica superior, which have depended upon the patients' state severity, caused by reduction of the volume blood flow in a certan vascular collector. The oxygen debt of the liver in these patients is compensated by the volume blood flow enhancement along a. hepatis communis.

  3. Prevention of Post Transfusion Hepatitis Employing Sensitive Assay for Hepatitis B Surface Antigen Screening(Topics in Transfusion Medicine 1990 : Autologous Transfusion and Post-Transfusion Hepatitis)

    OpenAIRE

    小島, 秀男; 大竹, 幸子; 富樫, 和枝; 石口, 重子; 山田, 恵子; 品田, 章二; Kojima, Hideo; Ohtake, Sachiko; Togashi, Kazue; Ishiguchi, Shigeko; Yamada, Keiko; Shinada, Shoji

    1990-01-01

    Post transfusion Hepatitis (PTH) is one of serious side effects and some times lead to fulminant hepatic failure in case transfused blood contain very low level (under the sensitivity of usual screening method) of hepatitis B virus (HBV). Redcross blood center and blood transfusion devision of our hospital have been employed reverse passive hemmaglutination method (RPHA) for HBsAg screening. Authors employed EIA for sensitive HBsAg test system and compared with RPHA method. Of 2,255 sera from...

  4. Electroencephalography reveals lower regional blood perfusion and atrophy of the temporoparietal network associated with memory deficits and hippocampal volume reduction in mild cognitive impairment due to Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Moretti DV

    2015-02-01

    Full Text Available Davide Vito MorettiNational Institute for the research and cure of Alzheimer’s disease, S. John of God, Fatebenefratelli, Brescia, Italy Background: An increased electroencephalographic (EEG upper/lower alpha power ratio has been associated with less regional blood perfusion, atrophy of the temporoparietal region of the brain, and reduction of hippocampal volume in subjects affected by mild cognitive impairment due to Alzheimer’s disease as compared with subjects who do not develop the disease. Moreover, EEG theta frequency activity is quite different in these groups. This study investigated the correlation between biomarkers and memory performance.Methods: EEG α3/α2 power ratio and cortical thickness were computed in 74 adult subjects with prodromal Alzheimer’s disease. Twenty of these subjects also underwent assessment of blood perfusion by single-photon emission computed tomography (SPECT. Pearson’s r was used to assess the correlation between cortical thinning, brain perfusion, and memory impairment.Results: In the higher α3/α2 frequency power ratio group, greater cortical atrophy and lower regional perfusion in the temporoparietal cortex was correlated with an increase in EEG theta frequency. Memory impairment was more pronounced in the magnetic resonance imaging group and SPECT groups.Conclusion: A high EEG upper/low alpha power ratio was associated with cortical thinning and less perfusion in the temporoparietal area. Moreover, atrophy and less regional perfusion were significantly correlated with memory impairment in subjects with prodromal Alzheimer’s disease. The EEG upper/lower alpha frequency power ratio could be useful for identifying individuals at risk for progression to Alzheimer’s dementia and may be of value in the clinical context.Keywords: electroencephalography, perfusion, atrophy, temporoparietal network, memory deficits, hippocampal volume, mild cognitive impairment, Alzheimer’s disease

  5. Influence of antihypertensive therapy on cerebral perfusion in patients with metabolic syndrome: relationship with cognitive function and 24-h arterial blood pressure monitoring.

    Science.gov (United States)

    Efimova, Nataliya Y; Chernov, Vladimir I; Efimova, Irina Y; Lishmanov, Yuri B

    2015-08-01

    To investigate the regional cerebral blood flow, cognitive function, and parameters of 24-h arterial blood pressure monitoring in patients with metabolic syndrome before and after combination antihypertensive therapy. The study involved 54 patients with metabolic syndrome (MetS) investigated by brain single-photon emission computed tomography, 24-h blood pressure monitoring (ABPM), and comprehensive neuropsychological testing before and after 24 weeks of combination antihypertensive therapy. Patients with metabolic syndrome had significantly poorer regional cerebral blood flow compared with control group: by 7% (P = 0.003) in right anterior parietal cortex, by 6% (P = 0.028) in left anterior parietal cortex, by 8% (P = 0.007) in right superior frontal lobe, and by 10% (P = 0.00002) and 7% (P = 0.006) in right and left temporal brain regions, correspondingly. The results of neuropsychological testing showed 11% decrease in mentation (P = 0.002), and 19% (P = 0.011) and 20% (P = 0.009) decrease in immediate verbal and visual memory in patients with MetS as compared with control group. Relationships between the indices of ABPM, cerebral perfusion, and cognitive function were found. Data showed an improvement of regional cerebral blood flow, ABPM parameters, and indicators of cognitive functions after 6 months of antihypertensive therapy in patients with MetS. The study showed the presence of diffuse disturbances in cerebral perfusion is associated with cognitive disorders in patients with metabolic syndrome. Combination antihypertensive treatment exerts beneficial effects on the 24-h blood pressure profile, increases cerebral blood flow, and improves cognitive function in patients with MetS. © 2015 John Wiley & Sons Ltd.

  6. Effects of hepatic ischemia-reperfusion injury on the blood-brain barrier permeability to [14C] and [13C]sucrose.

    Science.gov (United States)

    Miah, Mohammad K; Bickel, Ulrich; Mehvar, Reza

    2017-12-01

    Hepatic encephalopathy that is associated with severe liver failure may compromise the blood-brain barrier (BBB) integrity. However, the effects of less severe liver diseases, in the absence of overt encephalopathy, on the BBB are not well understood. The goal of the current study was to investigate the effects of hepatic ischemia-reperfusion (IR) injury on the BBB tight junction permeability to small, hydrophilic molecules using the widely used [ 14 C]sucrose and recently-proposed alternative [ 13 C]sucrose as markers. Rats were subjected to 20 min of hepatic ischemia or sham surgery, followed by 8 h of reperfusion before administration of a single bolus dose of [ 14 C] or [ 13 C]sucrose and collection of serial (0-30 min) blood and plasma and terminal brain samples. The concentrations of [ 14 C] and [ 13 C]sucrose in the samples were determined by measurement of total radioactivity (nonspecific) and LC-MS/MS (specific), respectively. IR injury significantly increased the blood, plasma, and brain concentrations of both [ 14 C] and [ 13 C]sucrose. However, when the brain concentrations were corrected for their respective area under the blood concentration-time curve, only [ 14 C]sucrose showed significantly higher (30%) BBB permeability values in the IR animals. Because [ 13 C]sucrose is a more specific BBB permeability marker, these data indicate that our animal model of hepatic IR injury does not affect the BBB tight junction permeability to small, hydrophilic molecules. Methodological differences among studies of the effects of liver diseases on the BBB permeability may confound the conclusions of such studies.

  7. The effect of perfusion and irrigation flow rate variations on NaCl efflux from the isolated, perfused head of the marine teleost, Myoxocephalus octodecimspinosus

    International Nuclear Information System (INIS)

    Claiborne, J.B.; Evans, D.H.

    1981-01-01

    In vivo branchial blood pressure and unidirectional efflux values for NaCl were determined in the marine teleost, Myoxocephalus octodecimspinosus. Utilizing an isolated, perfused head preparation, perfused at in vivo pressure levels, NaCl efflux was measured and compared to in vivo values. The effect of variations in perfusion or irrigation rates on the ion efflux across the gills of the isolated head was also studied. The efflux of 22 Na from the isolated, perfused head was found to be similar to in vivo values and dependent on perfusion flow and pressure. In vitro 36 Cl efflux was lower than the efflux from intact animals and was determined to be flow/pressure independent. Irrigation rate changes at all rates tested did not affect the unidirectional efflux of either ion. (Auth.)

  8. Myocardial perfusion as an indicator of graft patency after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Kolibash, A.J.; Call, T.D.; Bush, C.A.; Tetalman, M.R.; Lewis, R.P.

    1980-01-01

    Stress and resting myocardial perfusion were assessed in 38 patients who received 96 grafts. Stress perfusion was evaluated with thallium-201 and resting myocardial blood flow distribution with radiolabeled particles. When both stress and rest perfusion were normal, graft patency was 82% (51 of 62 grafts). Graft patency was also high (81%, 13 of 16) in areas where stress perfusion abnormalities resolved or become less apparent at rest. However, when stress perfusion defects remained unchanged at rest, the graf was likely to be occuluded (73%, 11 of 15). Maintenance of normal rest perfusion or improvement of rest perfusion postoperatively was also associated with a high graft patency rate (80%, 35 of 44), whereas the development of new rest perfusion defects postoperatively implied graft occlusion

  9. Microarray multiplex assay for the simultaneous detection and discrimination of hepatitis B, hepatitis C, and human immunodeficiency type-1 viruses in human blood samples

    International Nuclear Information System (INIS)

    Hsia, Chu Chieh; Chizhikov, Vladimir E.; Yang, Amy X.; Selvapandiyan, Angamuthu; Hewlett, Indira; Duncan, Robert; Puri, Raj K.; Nakhasi, Hira L.; Kaplan, Gerardo G.

    2007-01-01

    Hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type-1 (HIV-1) are transfusion-transmitted human pathogens that have a major impact on blood safety and public health worldwide. We developed a microarray multiplex assay for the simultaneous detection and discrimination of these three viruses. The microarray consists of 16 oligonucleotide probes, immobilized on a silylated glass slide. Amplicons from multiplex PCR were labeled with Cy-5 and hybridized to the microarray. The assay detected 1 International Unit (IU), 10 IU, 20 IU of HBV, HCV, and HIV-1, respectively, in a single multiplex reaction. The assay also detected and discriminated the presence of two or three of these viruses in a single sample. Our data represent a proof-of-concept for the possible use of highly sensitive multiplex microarray assay to screen and confirm the presence of these viruses in blood donors and patients

  10. Brain perfusion CT in acute stroke: current status

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Matthias E-mail: matthias.koenig@ruhr-uni-bochum.de

    2003-03-01

    Dynamic perfusion CT has become a widely accepted imaging modality for the diagnostic workup of acute stroke patients. Although compared with standard spiral CT the use of multislice CT has broadened the range from which perfusion data may be derived in a single scan run. The advent of multidetector row technology has not really overcome the limited 3D capability of this technique. Multidetector CT angiography (CTA) of the cerebral arteries may in part compensate for this by providing additional information about the cerebrovascular status. This article describes the basics of cerebral contrast bolus scanning with a special focus on optimization of contrast/noise in order to ensure high quality perfusion maps. Dedicated scan protocols including low tube voltage (80 kV) as well as the use of highly concentrated contrast media are amongst the requirements to achieve optimum contrast signal from the short bolus passage through the brain. Advanced pre and postprocessing algorithms may help reduce the noise level, which may become critical in unconscious stroke victims. Two theoretical concepts have been described for the calculation of tissue perfusion from contrast bolus studies, both of which can be equally employed for brain perfusion imaging. For each perfusion model there are some profound limitations regarding the validity of perfusion values derived from ischemic brain areas. This makes the use of absolute quantitative cerebral blood flow (CBF) values for the discrimination of the infarct core from periinfarct ischemia questionable. Multiparameter imaging using maps of CBF, cerebral blood volume (CBV), and a time parameter of the local bolus transit enables analyzing of the cerebral perfusion status in detail. Perfusion CT exceeds plain CT in depicting cerebral hypoperfusion at its earliest stage yielding a sensitivity of about 90% for the detection of embolic and hemodynamic lesions within cerebral hemispheres. Qualitative assessment of brain perfusion can be

  11. (-) Epicatechin regulates blood lipids and attenuates hepatic steatosis in rats fed high fat diet

    Science.gov (United States)

    (-)-Epicatechin (EC) is a natural flavanol monomer found in cocoa, green tea and a variety of other plant foods. Recent studies have shown that EC and foods rich in EC exerted vascular protective effects. In this study, effects of EC on blood lipids and hepatic steatosis, and the underlying mechani...

  12. Presencia del antígeno de superficie del virus hepatitis B en donantes de sangre Presence of hepatitis B surface antigen in blood donors

    Directory of Open Access Journals (Sweden)

    Yarelis Prieto Hernández

    2013-06-01

    , applied and prospective study was conducted with blood donors in Sandino municipality from September 2010 to August 2011; an epidemiological survey was applied along with hepatitis B surface antigen performed to a sample of 1420 donors. Results: 18 positive hepatitis B surface antigen were found (1,3%, ages from 18-34 (45,2% and Caucasian race prevailed (60,2%, the 80,7% had no surgical interventions, the sexual preference was heterosexual(99,3% and those not having tattoos predominated with 99,3%. Regarding the last dental treatment, the group who did not undergo this treatment was more representative 67,2% finding a statistical significant difference. Conclusions: blood donors presented a high prevalence of hepatitis B virus in Sandino municipality, where no association was found among age, race, surgical interventions, sexual preference, tattoos and the onset of hepatitis B. On the contrary, a relationship between hepatitis B and dental treatment was found.

  13. Local cortical hypoperfusion imaged with CT perfusion during postictal Todd's paresis

    International Nuclear Information System (INIS)

    Mathews, Marlon S.; Binder, Devin K.; Smith, Wade S.; Wintermark, Max; Dillon, William P.

    2008-01-01

    Postictal (''Todd's'') paralysis, or ''epileptic hemiplegia,'' is a well-known complication of focal or generalized epileptic seizures. However, it is unclear whether the pathophysiology of Todd's paralysis is related to alterations in cerebral perfusion. We report CT perfusion findings in a patient presenting with postictal aphasia and right hemiparesis. A 62-year-old woman with a history of alcohol abuse, closed head injury and posttraumatic epilepsy, presented with acute onset aphasia and right hemiparesis. A non-contrast head CT scan demonstrated no acute hemorrhage. Left hemispheric ischemia was suspected, and the patient was considered for acute thrombolytic therapy. MRI revealed a subtle increase in signal intensity involving the left medial temporal, hippocampal and parahippocampal regions on both T2-weighted FLAIR and diffusion-weighted sequences. CT angiography and CT perfusion study were performed. The CT perfusion study and CT angiography demonstrated a dramatic reduction in cerebral blood flow and blood volume involving the entire left hemisphere, but with relative symmetry of mean transit time, ruling out a large vessel occlusion. Clinical resolution of the aphasia and hemiparesis occurred within a few hours, and correlated with normalization of perfusion to the left hemisphere (detected by MR perfusion). This unique case is the first in which clinical evidence of Todd's paralysis has been correlated with reversible postictal hemispheric changes on CT and MR perfusion studies. This is important because CT perfusion study is being used more and more in the diagnosis of acute stroke, and one needs to be careful to not misinterpret the data. (orig.)

  14. Hyperperfusion on Perfusion Computed Tomography Following Revascularization for Acute Stroke

    International Nuclear Information System (INIS)

    Nguyen, T.B.; Lum, C.; Eastwood, J.D.; Stys, P.K.; Hogan, M.; Goyal, M.

    2005-01-01

    Purpose: To describe the findings of hyperperfusion on perfusion computed tomography (CT) in four patients following revascularization for acute stroke. Material and Methods: In 2002-2003, among a series of 6 patients presenting with an acute stroke and treated with intra-arterial thrombolysis, we observed the presence of hyperperfusion in 3 patients on the follow-up CT perfusion. We included an additional patient who was treated with intravenous thrombolysis and who had hyperperfusion on the follow-up CT perfusion. We retrospectively analyzed their CT perfusion maps. Cerebral blood volume (CBV) and cerebral blood flow (CBF) maps were compared between the affected territory and the normal contralateral hemisphere. Results: In the four patients, the mean CBV and CBF were 3.6±2.0 ml/100 g and 39±25 ml/100 g/min in the affected territory compared to the normal side (mean CBV 2.7±2.1 ml/100 g, mean CBF = 27±23 ml/100 g/min). There was no intracranial hemorrhage in the hyperperfused territories. At follow-up CT, some hyperperfused brain areas progressed to infarction, while others retained normal white to gray matter differentiation. Conclusion: CT perfusion can demonstrate hyperperfusion, which can be seen in an ischemic brain territory following recanalization

  15. The advantage of high relaxivity contrast agents in brain perfusion

    International Nuclear Information System (INIS)

    Cotton, F.; Hermier, M.

    2006-01-01

    Accurate MRI characterization of brain lesions is critical for planning therapeutic strategy, assessing prognosis and monitoring response to therapy. Conventional MRI with gadolinium-based contrast agents is useful for the evaluation of brain lesions, but this approach primarily depicts areas of disruption of the blood-brain barrier (BBB) rather than tissue perfusion. Advanced MR imaging techniques such as dynamic contrast agent-enhanced perfusion MRI provide physiological information that complements the anatomic data available from conventional MRI. We evaluated brain perfusion imaging with gadobenate dimeglumine (Gd-BOPTA, MultiHance; Bracco Imaging, Milan, Italy). The contrast-enhanced perfusion technique was performed on a Philips Intera 1.5-T MR system. The technique used to obtain perfusion images was dynamic susceptibility contrast-enhanced MRI, which is highly sensitive to T2* changes. Combined with PRESTO perfusion imaging, SENSE is applied to double the temporal resolution, thereby improving the signal intensity curve fit and, accordingly, the accuracy of the derived parametric images. MultiHance is the first gadolinium MR contrast agent with significantly higher T1 and T2 relaxivities than conventional MR contrast agents. The higher T1 relaxivity, and therefore better contrast-enhanced T1-weighted imaging, leads to significantly improved detection of BBB breakdown and hence improved brain tumor conspicuity and delineation. The higher T2 relaxivity allows high-quality T2*-weighted perfusion MRI and the derivation of good quality relative cerebral blood volume (rCBV) maps. We determined the value of MultiHance for enhanced T2*-weighted perfusion imaging of histologically proven (by surgery or stereotaxic biopsy) intraaxial brain tumors (n=80), multiple sclerosis lesions (n=10), abscesses (n=4), neurolupus (n=15) and stroke (n=16). All the procedures carried out were safe and no adverse events occurred. The acquired perfusion images were of good quality in

  16. A randomized, controlled, double-blind crossover study on the effects of 1-L infusions of 6% hydroxyethyl starch suspended in 0.9% saline (voluven) and a balanced solution (Plasma Volume Redibag) on blood volume, renal blood flow velocity, and renal cortical tissue perfusion in healthy volunteers.

    Science.gov (United States)

    Chowdhury, Abeed H; Cox, Eleanor F; Francis, Susan T; Lobo, Dileep N

    2014-05-01

    We compared the effects of intravenous administration of 6% hydroxyethyl starch (maize-derived) in 0.9% saline (Voluven; Fresenius Kabi, Runcorn, United Kingdom) and a "balanced" preparation of 6% hydroxyethyl starch (potato-derived) [Plasma Volume Redibag (PVR); Baxter Healthcare, Thetford, United Kingdom] on renal blood flow velocity and renal cortical tissue perfusion in humans using magnetic resonance imaging. Hyperchloremia resulting from 0.9% saline infusion may adversely affect renal hemodynamics when compared with balanced crystalloids. This phenomenon has not been studied with colloids. Twelve healthy adult male subjects received 1-L intravenous infusions of Voluven or PVR over 30 minutes in a randomized, double-blind manner, with crossover studies 7 to 10 days later. Magnetic resonance imaging proceeded for 60 minutes after commencement of infusion to measure renal artery blood flow velocity and renal cortical perfusion. Blood was sampled, and weight was recorded at 0, 30, 60, 120, 180, and 240 minutes. Mean peak serum chloride concentrations were 108 and 106 mmol/L, respectively, after Voluven and PVR infusion (P = 0.032). Changes in blood volume (P = 0.867), strong ion difference (P = 0.219), and mean renal artery flow velocity (P = 0.319) were similar. However, there was a significant increase in mean renal cortical tissue perfusion after PVR when compared with Voluven (P = 0.033). There was no difference in urinary neutrophil gelatinase-associated liopcalin to creatinine ratios after the infusion (P = 0.164). There was no difference in the blood volume-expanding properties of the 2 preparations of 6% hydroxyethyl starch. The balanced starch produced an increase in renal cortical tissue perfusion, a phenomenon not seen with starch in 0.9% saline.

  17. Infusion MR arteriography during hepatic arterial infusion chemotherapy. Evaluation of clinical usefulness

    International Nuclear Information System (INIS)

    Uchino, Minako; Takizawa, Kenji

    2003-01-01

    We developed a new method of infusion MR arteriography (IMRA) via an implantable port system using an infusion pump for the evaluation of drug distribution during hepatic arterial infusion chemotherapy. The purposes of this study were to optimize the method and evaluate its clinical usefulness. We used 3D-T1 turbo field echo (TFE) as the most suitable sequence for IMRA according to the results of a phantom model experiment. We examined 33 cases of liver cancer that had been treated by arterial infusion chemotherapy via the port system. The following investigations were performed: degree of tumor enhancement, intra- and extra- hepatic perfusion abnormality, and related toxicity. The evaluation of images was performed separately by two radiologists. IMRA provided good images of contrast enhancement, to reveal the perfusion patterns. The treatment response rate in the tumor group with well enhancement was higher than that of the group with poor enhancement (p<0.0001). Extrahepatic perfusion was well visualized and was correlated with toxicity (p<0.0001). IMRA is a useful method to evaluate drug perfusion for the optimization of arterial infusion chemotherapy. (author)

  18. Characteristics of Brain Perfusion in Patients of Parkinson's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Young Jin; Park, Min Jung; Kim, Jae Woo; Kang, Young Kang [Dong-A University College of Medicine, Busan (Korea, Republic of)

    2008-02-15

    It was well known that cerebral blood perfusion is normal or diffusely decreased in the majority of patients with Parkinson's disease (PD). Actually we interpreted brain perfusion SPECT images of PD patients in the clinical situation, we observed various cerebral perfusion patterns in patients with PD. So we performed brain perfusion SPECT to know the brain perfusion patterns of PD patients and the difference of perfusion patterns according to the sex and the age. Also we classified PD patients into small groups based on the brain perfusion pattern. Two hundred nineteen patients (M: 70, F: 149, mean age: 62.9{+-}6.9 y/o) who were diagnosed as PD without dementia clinically and 55 patients (M: 15, F: 40, mean age: 61.4{+-}9.2 y/o) as normal controls who had no past illness history were performed {sup 99m}Tc-HMPAO brain perfusion SPECT and neuropsychological test. At first, we compared all patients with PD and normal controls. Brain perfusion in left inferior frontal gyrus, left insula, left transverse temporal gyrus, left inferior parietal lobule, left superior parietal lobule, right precuneus, right caudate tail were lower in patients with PD than normal controls. Secondly, we compared male and female patients with PD and normal controls, respectively. Brain perfusion SPECT showed more decreased cerebral perfusion in left hemisphere than right side in both male and female patients compared to normal controls. And there was larger hypoperfusion area in female patients compared with male. Thirdly, we classified patients with PD and normal controls into 4 groups according to the age and compared brain perfusion respectively. In patient below fifties, brain perfusion in both occipitoparietal and left temporal lobe were lower in PD group. As the patients with PD grew older, hypoperfusion area were shown in both frontal, temporal and limbic lobes. Fourthly, We were able to divide patients into small groups based on cerebral perfusion pattern. There was normal

  19. Normothermic extracorporeal perfusion of isolated porcine liver after warm ischaemia: a preliminary report.

    Science.gov (United States)

    Bellomo, Rinaldo; Suzuki, Satoshi; Marino, Bruno; Starkey, Graeme K; Chambers, Brenton; Fink, Michael A; Wang, Bao Zhong; Houston, Shane; Eastwood, Glenn; Calzavacca, Paolo; Glassford, Neil; Skene, Alison; Jones, Daryl A; Jones, Robert

    2012-09-01

    Liver transplantation is a major life-saving procedure, and donation after cardiac death (DCD) has increased the pool of potential liver donors. However, DCD livers are at increased risk of primary graft dysfunction and biliary tract ischaemia. Normothermic extracorporeal liver perfusion (NELP) may increase the ability to protect, evaluate and, in future, transplant DCD livers. We conducted proof-of-concept experiments using a DCD model in the pig to assess the short-term (4 hours) feasibility and functional efficacy of NELP. Using extracorporeal membrane oxygenation, parenteral nutrition, separate hepatic artery and portal vein perfusion, and physiological perfusion pressures, we achieved NELP and evidence of function (bile production, paracetamol removal, maintenance of normal ammonia and lactate levels) for 4 hours in pig livers subjected to 15 and 30 minutes of cardiac arrest before explantation. Our experiments justify further investigations of the feasibility and efficacy of human DCD liver preservation by ex-vivo perfusion.

  20. PREVENTION OF POST-TRANSFUSION HEPATITIS BY SCREENING OF ANTIBODY TO HEPATITIS B CORE ANTIGEN IN HEALTHY BLOOD DONORS

    Directory of Open Access Journals (Sweden)

    Sudha Bhat

    2011-01-01

    Full Text Available

    Background: Transfusion-associated hepatitis B viral infection continues to be a major problem in India even after adoption of mandatory screening for HBsAg by ELISA method. The high incidence of TAHBV is reported in patients receiving multiple transfusions.

    Objective: To study the seroprevalence of hepatitis B core antibody among healthy voluntary blood donors

    Subjects and Methods: The study was conducted in the department of Transfusion Medicine of a tertiary care referral hospital. A total of 12,232 volunteers after passing through the stringent criteria were selected for blood donation. Donor samples were tested for all mandatory transfusion transmissible infections and anti HBc IgM (Monolisa HBc IgM PLUS:BIO-RAD, France. Reactive results were confirmed by repeat testing in duplicate. Donor data was analyzed using SPSS software and Chi-square test was used to calculate the significance of difference between the groups.

    Results:A total of 12,232 healthy voluntary blood donors were recruited. Majority (93.4% were males. Median age of donor population was 26 years (range: 18-60 years. Eighty six (0.7% were positive for HBsAg, which comes under “low prevalence (<2% zone” as per WHO. On screening for HBcAg Ig M, 15 (0.1% were found to be positive and none were HBsAg reactive. There was no significance of difference in the mean age between reactive and non-reactive donors.

    Conclusion:Evaluating the usefulness of anti-HBc screening is critical. Anti HBcAg IgM screening may be included in routine screening of donors as it is an indicator of occult HBV during window period. The cost and the unnecessary wastage of the blood units when they are positive for anti HBsAg along with the core antibody need to be studied.

     

  1. Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Miles, K.A. [Wesley Research Inst., The Wesley Hospital, Brisbane (Australia); Brighton and Sussex Medical School, Univ. of Sussex, Falmer, Brighton (United Kingdom)

    2003-12-01

    Acute cerebral stroke remains a major cause of death among adults and the emergence of new therapies has created a need for early and rapid imaging at a time when conventional CT is either normal or demonstrates subtle abnormalities that are easy to misinterpret. Perfusion CT uses the temporal changes in cerebral and blood attenuation during a rapid series of images acquired without table movement following an intravenous bolus of contrast medium to generate images of mean transit time (MTT) cerebral blood volume (CBV) and perfusion. Reduced perfusion with preserved CBV is indicative of reversible ischaemia, whereas a matched reduction in perfusion and CBV implies infarction. The CT perfusion imaging can positively identify patients with non-haemorrhagic stroke in the presence of a normal conventional CT, provide an indication as to prognosis and potentially select those patients for whom thrombolysis is appropriate. Perfusion CT offers a powerful adjunct to MDCT based imaging of cerebrovascular disease, but further clinical validation is required. (orig.)

  2. Multiple surface antigen mutations in five blood donors with occult hepatitis B virus infection

    NARCIS (Netherlands)

    Zaaijer, H. L.; Torres, P.; Ontañón, A.; Ponte, L. González; Koppelman, M. H. G. M.; Lelie, P. N.; Hemert, F. J. van; Boot, H. J.

    2008-01-01

    Occult hepatitis B virus (HBV) infection is characterized by the presence of HBV DNA while the HBV surface antigen (HBsAg) remains undetectable. The HBV genomes in five asymptomatic blood donors with occult HBV infection and low viremia ( <10 to 1,000 HBV DNA copies/mL, genotype D) were studied. An

  3. Hepatitis B virus (image)

    Science.gov (United States)

    Hepatitis B is also known as serum hepatitis and is spread through blood and sexual contact. It is ... population. This photograph is an electronmicroscopic image of hepatitis B virus particles. (Image courtesy of the Centers for ...

  4. The utility of first-pass perfusion CT in hyperacute ischemic stroke: early experience

    International Nuclear Information System (INIS)

    Lee, Tae Jin; Lee, Myeong Sub; Kim, Myung Soon; Hong, In Soo; Lee, Young Han; Lee, Ji Yong; Whang, Kum

    2003-01-01

    To evaluate the findings of first-pass perfusion CT in hyperacute stroke patients and to determine the relationship between a perfusion map and final infarct outcome. Thirty-five patients admitted with ischemic stroke within six hours of the onset of symptoms underwent conventional cerebral CT immediately followed by first-pass perfusion CT. Nineteen underwent follow-up CT or MRI, and three types of dynamic perfusion map-cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) - were evaluated by two radiologists. In these 19 patients, initial perfusion maps correlated with final infarct size, determined during follow-up studies. In all 35 patients, major large vessel perfusion abnormalities [middle cerebral artery - MCA MCA and anterior cerebral artery - ACA (n=2); posterior cerebral artery - PCA (n=8)] were detected. On first-pass perfusion maps depicting CBF and MTT, all lesions were detected, and CBF and delayed MTT values were recorded. CBV maps showed variable findings. In all 19 patients who were followed up, the final infarct size of perfusion abnormalities was less than that depicted on CBF and MTT maps, and similar to or much greater than that seen on CBV maps. First-pass perfusion CT scanning is a practical, rapid and advanced imaging technique. In hyperacute stroke patients, it provides important and reliable hemodynamic information as to which brain tissue is salvageable by thrombolytic therapy, and predicts outcome of such treatment

  5. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study

    DEFF Research Database (Denmark)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf

    2006-01-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this...

  6. Hepatic bilirubin uptake in the isolated perfused rat liver is not facilitated by albumin binding

    International Nuclear Information System (INIS)

    Stollman, Y.R.; Gaertner, U.; Theilmann, L.; Ohmi, N.; Wolkoff, A.W.

    1983-01-01

    Bilirubin uptake by the liver has kinetic characteristics which suggest carrier-mediation. Bilirubin is readily bound to albumin. A liver cell surface receptor for albumin has been postulated. The present study was designed to examine directly whether albumin facilitates the hepatic uptake of bilirubin and whether uptake of bilirubin depends on binding to albumin. Rat liver was perfused with a protein-free fluorocarbon medium, and single-pass uptake of 1, 10, or 200 nmol of [ 3 H]bilirubin was determined after injection as an equimolar complex with 125 I-albumin, with 125 I-ligandin, or free with only a [ 14 C]sucrose reference. Uptake of 10 nmol of [ 3 H]bilirubin was 67.5 +/- 3.7% of the dose when injected with 125 I-albumin, 67.4 +/- 6.5% when injected with 125 I-ligandin, and 74.9 +/- 2.4% when injected with [ 14 C]sucrose (P greater than 0.1). At 200 nmol, uptake fell to 46.4 +/- 3.1% ( 125 I-albumin) and 63.3 +/- 3.4% [( 14 C]sucrose) of injected [ 3 H]bilirubin (P less than 0.01), which suggests saturation of the uptake mechanism. When influx was quantitated by the model of Goresky, similar results were obtained. When [ 3 H]bilirubin was injected simultaneously with equimolar 125 I-albumin and a [ 14 C]sucrose reference, there was no delay in 125 I-albumin transit as compared with that of [ 14 C]sucrose. This suggested that the off-rate of albumin from a putative hepatocyte receptor would have to be very rapid, which is unusual for high affinity receptor-ligand interaction. There was no evidence for facilitation of bilirubin uptake by binding to albumin or for interaction of albumin with a liver cell surface receptor. These results suggest that the hepatic bilirubin uptake mechanism is one of high affinity which can extract bilirubin from circulating carriers such as albumin, ligandin, or fluorocarbon

  7. Intra-voxel incoherent motion perfusion MR Imaging: a wake-up call

    Energy Technology Data Exchange (ETDEWEB)

    Le Bihan, D. [CEA Saclay, DSV, I2BM, F-91191 Gif Sur Yvette (France)

    2008-07-01

    This work gives the results of several studies made by different authors on IVIM MR Imaging. It appears that there are genuine potential applications for IVIM MR imaging. Perfusion is a very important surrogate marker of many physiologic or pathologic processes. MR imaging perfusion parameters can be obtained by using gadolinium-based contrast agents, either injected as a bolus (to determine blood flow, transit times, etc) or in a steady-state mode (to address blood volume, vessel permeability, etc). With the rising concern of nephrogenic systemic fibrosis, some patients cannot be examined with such an approach. IVIM MR imaging may then appear as an interesting alternative to provide crucial clues on perfusion in tissues, such as the kidneys, the liver, or even the placenta during pregnancy. (O.M.)

  8. Intra-voxel incoherent motion perfusion MR Imaging: a wake-up call

    International Nuclear Information System (INIS)

    Le Bihan, D.

    2008-01-01

    This work gives the results of several studies made by different authors on IVIM MR Imaging. It appears that there are genuine potential applications for IVIM MR imaging. Perfusion is a very important surrogate marker of many physiologic or pathologic processes. MR imaging perfusion parameters can be obtained by using gadolinium-based contrast agents, either injected as a bolus (to determine blood flow, transit times, etc) or in a steady-state mode (to address blood volume, vessel permeability, etc). With the rising concern of nephrogenic systemic fibrosis, some patients cannot be examined with such an approach. IVIM MR imaging may then appear as an interesting alternative to provide crucial clues on perfusion in tissues, such as the kidneys, the liver, or even the placenta during pregnancy. (O.M.)

  9. Transplacental transfer of nitrosodimethylamine in perfused human placenta.

    OpenAIRE

    Annola, K.; Heikkinen, A.T.; Partanen, H.; Woodhouse, H.; Segerback, D.; Vahakangas, K.

    2009-01-01

    Nitrosodimethylamine (NDMA) is a carcinogenic compound present in tobacco smoke and food such as cured meat, smoked fish and beer. The O(6)-methylguanine formed in human cord blood in mothers highly exposed to such products implicates NDMA exposure of the fetus. Dual recirculating human placental perfusion was used to get direct evidence of the transplacental transfer of NDMA and DNA adduct formation in perfused human placenta. Eleven placentas from normal full-term pregnancies were collected...

  10. Assessment of right liver graft perfusion effectiveness between one and two-catheter infusion methods.

    Science.gov (United States)

    Jung, Bo-Hyun; Hwang, Shin; Ha, Tae-Yong; Song, Gi-Won; Jung, Dong-Hwan; Kim, Ki-Hun; Ahn, Chul-Soo; Moon, Deok-Bog; Park, Gil-Chun; Kang, Sung-Hwa; Yoon, Young-In; Lee, Sung-Gyu

    2014-05-01

    Conventional graft perfusion method using one small-caliber catheter takes a relatively long time for right liver graft perfusion, thus some modification is needed. In this study, we intended to assess the effectiveness of right liver graft perfusion methods through comparison of different infusion catheters. The study consisted of two parts including one bench experiment to obtain data of hydraulic infusion and one clinical trial of 40 cases on graft perfusion with one- versus two-catheter infusion methods. These two graft infusion methods were compared in terms of the perfusion time and washing-out efficiency. At bench experiment, the infusion flow rate and infusion pressure were 3.3 ml/sec and 1.9 cmH20 in one blood transfusion catheter group, and 11.7 ml/sec and 3.1 cmH20 in single transurethral resection of prostate irrigation catheter group, and 6.6 ml/sec and 2.0 cmH20 in two blood transfusion catheters group, respectively. In clinical trial with 40 right liver grafts, two-catheter group had a shorter graft portal perfusion time for the first 2 L of histidine-tryptophan-ketoglutarate (HTK) solution than the conventional one-catheter group (375±25 seconds vs. 662±34 seconds; p=0.001) and a lower rate of incomplete blood washing-out after the initial 2 L portal perfusion (40% vs. 85%; p=0.03). The two-catheter infusion method appears to be more effective than the conventional one-catheter infusion method for right liver graft perfusion at the back table. Large size of right liver grafts seems to be its good indication.

  11. Elimination of extracranial blood flow during dynamic cerebral perfusion studies using diffusible and non-diffusible radioisotope

    International Nuclear Information System (INIS)

    Ahonen, A.; Koivula, A.; Kallanranta, T.; Kuikka, J.

    1981-01-01

    The extracranial blood flow seriously complicates the interpretation of dynamic cerebral studies. To eliminate this, we used a blood pressure cuff placed around the head in 50 patients with no evidence of cerebrovascular disease. The pressure in the headband was increased to 30 mmHg above the patient's systolic pressure, and the first 60 sec static scintigram was taken exactly 3 min after the injection of sup(99m)Tc-pertechnetate. A second 60 sec static scintigram was taken without pressure in the headband at 6 min after injection. After correction for diffusion of tracer into extravascular compartments we could still show 13% reduction in counting rates over the hemispheric regions and 30% over the convexity regions during application of the pressure headband. With the Xenon method, the application of the headband appears to have insignificant influence on the results of cerebral perfusion. We thus recommend that a headband should be used for dynamic sup(99m)Tc-isotope cerebral circulation studies. (author)

  12. The investigation of in-vivo measurement of individual renal blood perfusion, effective renal plasma flow and quantitation of renogram and 15 min bladder collection percentage

    International Nuclear Information System (INIS)

    Huang Kangchu

    1991-01-01

    25 normals and 43 renal diseases were examined by the RBF-I multifunctioning renography. The result showed that the determination of ERPF has no difference between blood sampling and noin-blood sampling method, and actually the lattrer can replace the former one. Above method can be also used for the measurement of the individual renal blood perfusion, the quantitation of renogram and the 15 min bladder coolection percentage at the same time. Thereby it provides more complete diagnostic information for the renal vascular diseases, renal pancren chymations and other urologic diseases

  13. Assessment of Cu-ETS as a PET radiopharmaceutical for evaluation of regional renal perfusion

    International Nuclear Information System (INIS)

    Green, Mark A.; Mathias, Carla J.; Willis, Lynn R.; Handa, Rajash K.; Lacy, Jeffrey L.; Miller, Michael A.; Hutchins, Gary D.

    2007-01-01

    The copper(II) complex of ethylglyoxal bis(thiosemicarbazone) (Cu-ETS) was evaluated as a positron emission tomography (PET) radiopharmaceutical for assessment of regional renal perfusion. Methods: The concordance of renal flow estimates obtained with 11- and 15-μm microspheres was confirmed in four immature farm pigs using co-injected 46 Sc- and 57 Co-microspheres administered into the left ventricle. With the use of both immature farm pigs (n=3) and mature Goettingen minipigs (n=6), regional renal radiocopper uptake following intravenous [ 64 Cu]Cu-ETS administration was compared to microsphere measurements of renal perfusion. The distribution and kinetics of [ 64 Cu]Cu-ETS were further studied by PET imaging of the kidneys. The rate of [ 64 Cu]Cu-ETS decomposition by blood was evaluated in vitro, employing octanol extraction to recover intact [ 64 Cu]Cu-ETS. Results: The co-injected 11- and 15-μm microspheres provided similar estimates of renal flow. A linear relationship was observed between the renal uptake of intravenous [ 64 Cu]Cu-ETS and regional renal perfusion measured using microspheres. [ 64 Cu]Cu-ETS provided high-quality PET kidney images demonstrating the expected count gradient from high-flow outer cortex to low-flow medulla. When incubated with pig blood in vitro at 37 o C, the [ 64 Cu]Cu-ETS radiopharmaceutical was observed to decompose with a half-time of 2.8 min. Conclusion: Cu-ETS appears suitable for use as a PET radiopharmaceutical for evaluation of regional renal perfusion, affording renal uptake of radiocopper that varies linearly with microsphere perfusion measurements. Quantification of renal perfusion (in ml min -1 g -1 ) with [ 60,61,62,64 Cu]Cu-ETS will require correcting the arterial input function for the fraction of blood radiocopper remaining present as the intact Cu-ETS radiopharmaceutical, since the Cu-ETS chelate has limited chemical stability in blood. Rapid octanol extraction of blood samples appears suitable as an approach

  14. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus.

    Science.gov (United States)

    Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E; Elkins, William; Nardone, Glenn A; Emerson, Suzanne U; Purcell, Robert H

    2007-06-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper discs from freshly killed deer. The discs were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of blood absorbed and were eluted and collected in one tube via a novel extraction system. The procedure was quantified and validated with negative and positive serum and blood samples obtained from domestic Sika deer before and after immunization with HEV recombinant capsid protein, respectively. None of the 155 tested samples contained antibody to HEV, suggesting that Sika deer in these populations, unlike those in Japan, do not pose a significant zoonotic threat for hepatitis E. However, the new method developed for collecting and eluting the samples should prove useful for field studies of many other pathogens.

  15. A study on the relationship of anti-HCV antibody and hepatitis C viremia in post-transfusion hepatitis

    International Nuclear Information System (INIS)

    Lee, Dong Soon

    1993-01-01

    The specimens of blood transfusion recipients who recieved the Anti-HCV antibody positive bloods were analyzed at irregular intervals by enzyme immunoassay to measure the anti-HCV antibody and reverse transcription PCR of hepatitis C virus to evaluate the viremic states. At the same time, the specimens of anti-HCV antibody positive healthy blood donors are analyzed by the reverse transcription PCR method. We analyzed the 9 cases of anti-HCV positive blood donors by reverse transcription PCR and no cases of positive HCV reverse transcription PCR is found. The 5 patients who recieved the anti-HCV positive blood by blood transfusion was followed at irregular interval. Of 5 blood recipients, Hepatitis C virus was detected in 2 patients (40%) and Anti-HCV antibody was detected in 2 patients (40%). We suppose that in contrast to disease group (Non A non B hepatitis), the possibility of viremia in the anti-HCV positive blood donors is significantly low and the character of those antibody may be convalescent antibody after hepatitis C resolution. (Author)

  16. A study on the relationship of anti-HCV antibody and hepatitis C viremia in post-transfusion hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Soon [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1993-01-01

    The specimens of blood transfusion recipients who recieved the Anti-HCV antibody positive bloods were analyzed at irregular intervals by enzyme immunoassay to measure the anti-HCV antibody and reverse transcription PCR of hepatitis C virus to evaluate the viremic states. At the same time, the specimens of anti-HCV antibody positive healthy blood donors are analyzed by the reverse transcription PCR method. We analyzed the 9 cases of anti-HCV positive blood donors by reverse transcription PCR and no cases of positive HCV reverse transcription PCR is found. The 5 patients who recieved the anti-HCV positive blood by blood transfusion was followed at irregular interval. Of 5 blood recipients, Hepatitis C virus was detected in 2 patients (40%) and Anti-HCV antibody was detected in 2 patients (40%). We suppose that in contrast to disease group (Non A non B hepatitis), the possibility of viremia in the anti-HCV positive blood donors is significantly low and the character of those antibody may be convalescent antibody after hepatitis C resolution. (Author).

  17. Fast Doppler as a novel bedside measure of cerebral perfusion in preterm infants.

    Science.gov (United States)

    Peeples, Eric S; Mehic, Edin; Mourad, Pierre D; Juul, Sandra E

    2016-02-01

    Altered cerebral perfusion from impaired autoregulation may contribute to the morbidity and mortality associated with premature birth. We hypothesized that fast Doppler imaging could provide a reproducible bedside estimation of cerebral perfusion and autoregulation in preterm infants. This is a prospective pilot study using fast Doppler ultrasound to assess blood flow velocity in the basal ganglia of 19 subjects born at 26-32 wk gestation. Intraclass correlation provided a measure of test-retest reliability, and linear regression of cerebral blood flow velocity and heart rate or blood pressure allowed for estimations of autoregulatory ability. The intraclass correlation when imaging in the first 48 h of life was 0.634. We found significant and independent correlations between the systolic blood flow velocity and both systolic blood pressure and heart rate (P = 0.015 and 0.012 respectively) only in the 26-28 wk gestational age infants in the first 48 h of life. Our results suggest that fast Doppler provides reliable bedside measurements of cerebral blood flow velocity at the tissue level in premature infants, acting as a proxy for cerebral tissue perfusion. Additionally, autoregulation appears to be impaired in the extremely preterm infants, even within a normal range of blood pressures.

  18. Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Detre, John A. E-mail: detre@mail.med.upenn.edu; Alsop, David C

    1999-05-01

    Several methods are now available for measuring cerebral perfusion and related hemodynamic parameters using magnetic resonance imaging (MRI). One class of techniques utilizes electromagnetically labeled arterial blood water as a noninvasive diffusible tracer for blood flow measurements. The electromagnetically labeled tracer has a decay rate of T1, which is sufficiently long to allow perfusion of the tissue and microvasculature to be detected. Alternatively, electromagnetic arterial spin labeling (ASL) may be used to obtain qualitative perfusion contrast for detecting changes in blood flow, similar to the use of susceptibility contrast in blood oxygenation level dependent functional MRI (BOLD fMRI) to detect functional activation in the brain. The ability to obtain blood flow maps using a non-invasive and widely available modality such as MRI should greatly enhance the utility of blood flow measurement as a means of gaining further insight into the broad range of hemodynamically related physiology and pathophysiology. This article describes the biophysical considerations pertaining to the generation of quantitative blood flow maps using a particular form of ASL in which arterial blood water is continuously labeled, termed continuous arterial spin labeling (CASL). Technical advances permit multislice perfusion imaging using CASL with reduced sensitivity to motion and transit time effects. Interpretable cerebral perfusion images can now be reliably obtained in a variety of clinical settings including acute stroke, chronic cerebrovascular disease, degenerative diseases and epilepsy. Over the past several years, the technical and theoretical foundations of CASL perfusion MRI techniques have evolved from feasibility studies into practical usage. Currently existing methodologies are sufficient to make reliable and clinically relevant observations which complement structural assessment using MRI. Future technical improvements should further reduce the acquisition times

  19. Bringing physiology into PET of the liver.

    Science.gov (United States)

    Keiding, Susanne

    2012-03-01

    Several physiologic features make interpretation of PET studies of liver physiology an exciting challenge. As with other organs, hepatic tracer kinetics using PET is quantified by dynamic recording of the liver after the administration of a radioactive tracer, with measurements of time-activity curves in the blood supply. However, the liver receives blood from both the portal vein and the hepatic artery, with the peak of the portal vein time-activity curve being delayed and dispersed compared with that of the hepatic artery. The use of a flow-weighted dual-input time-activity curve is of importance for the estimation of hepatic blood perfusion through initial dynamic PET recording. The portal vein is inaccessible in humans, and methods of estimating the dual-input time-activity curve without portal vein measurements are being developed. Such methods are used to estimate regional hepatic blood perfusion, for example, by means of the initial part of a dynamic (18)F-FDG PET/CT recording. Later, steady-state hepatic metabolism can be assessed using only the arterial input, provided that neither the tracer nor its metabolites are irreversibly trapped in the prehepatic splanchnic area within the acquisition period. This is used in studies of regulation of hepatic metabolism of, for example, (18)F-FDG and (11)C-palmitate.

  20. [ALAT and viral RNA as risk factors in 68 blood donors with anti-hepatitis C antibodies].

    Science.gov (United States)

    Tullen, E; De Saussure, P; Soulier-Lauper, M

    1993-01-23

    Determine the risk factors in blood donors with anti hepatitis C antibodies (anti-HCV ab) possible liver involvement and evaluation of their infectious potential by a search for viral RNA in blood. Between July 1990 and October 1991, 19,632 blood donors were screened for hepatitis C. Antibodies to HCV were detected in 74 donors (2nd generation ELISA, Abbott). We evaluated the risk factors, determined ALAT levels and looked for circulating RNA virus by amplification of the non-coding region of the viral genome (RTPCR) in 68 of these 74 donors screened. A control was chosen arbitrarily from 103 donors with high ALAT levels, but with no antibodies to HCV nor detectable circulating viral DNA. The prevalence of anti-HCV ab in blood donors in 0.37%. No risk factor was found in 29 donors (43%). Parenteral exposure (former i.v. drug addiction and history of transfusions) was found to be the mode of transmission of hepatitis C in 23 donors (34%). History of NANB jaundice (non-post transfusion) was reported in 1 donor (1%). The remaining 15 donors (22%) were found to have minor risk factors - either isolated or in combination (exposure, tatoos, multiple sexual partners). Former i.v. drug addiction (p = 0.0000006) as well as a history of transfusions (p = 0.0071) are significantly more frequent in the group of donors with antibodies to HCV. None of the 35 sexual partners of the tested donors proved to be positive. 21 donors (30%) had high ALAT (+2 SD). Viral RNA was detected in blood of 26 donors (38%). The proportion of cases with positive viral RNA was 61% if only those donors with high ALAT levels were taken into consideration (13 positive of 21). Risk factors were found in 39 donors (57%) with antibodies to HCV. History of parenteral exposure was found to be significantly more frequent than in the control group (p = 0.0000054). Sexual transmission within couples was not demonstrated in the population tested. A positive PCR test is a probable indicator of a continuous

  1. Angiohepatogram in diffuse hepatic disease

    International Nuclear Information System (INIS)

    Aburano, Tamio; Suzuki, Yutaka; Hisada, Kinichi; Matsudaira, Masamichi.

    1975-01-01

    A region of interest angiohepatogram was obtained with intravenous injection of 10mCi of sup(99m)Tc-Sn-colloid and a data processing system. Furthermore, the ratio of hepatic arterial blood flow volume to total hepatic blood flow volume was calculated according to Ueda's method, and the correlation of this calculated ratio and the degree of extrahepatic distribution of sup(99m)Tc-Sn-colloid (spleen to liver, and bone marrow to liver activity ratio) was examined. Most cases of liver cirrhosis and Banti's syndrome showed the increased hepatic arterial blood flow ratio (liver cirrhosis: 43.5+-9.5%, Banti's syndrome 48.8+-4.9%) in contrast with 18.1+-4.6% in normal cases, and its ratio showed much higher values in the presence of portal hypertension manifestations (esophageal varix and ascites). The hepatic arterial blood flow ratio showed increased values in the case of markedly increased extrahepatic activity, e.g. liver cirrhosis, and the correlation of the ratio and extrahepatic activity degree of sup(99m)Tc-Sn-colloid was significant statistically. From these results, a region of interest angiohepatogram was supposed to be useful for the prediction of the hemodynamic change, as well as, the improvement of diagnostic accuracy with radioisotope in diffuse hepatic disease, especially liver cirrhosis. Moreover, the hemodynamic change of liver, especially the reduction of the effective hepatic blood flow volume via the portal vein was considered to be closely concerned in the mechanism of increased extrahepatic activity of RI colloid in diffuse hepatic disease. (auth.)

  2. Blood perfusion in osteomyelitis studied with [15O]water PET in a juvenile porcine model

    DEFF Research Database (Denmark)

    Jødal, Lars; Nielsen, Ole L; Afzelius, Pia

    2017-01-01

    and not quantitative. Quantitative assessment of perfusion could aid in the selection of therapy. A non-invasive, quantitative way to study perfusion is dynamic [15O]water positron emission tomography (PET). We aim to demonstrate that the method can be used for measuring perfusion in OM lesions and hypothesize...... that perfusion will be less elevated in OM lesions than in soft tissue (ST) infection. The study comprised 11 juvenile pigs with haematogenous osteomyelitis induced by injection of Staphylococcus aureus into the right femoral artery 1 week before scanning (in one pig, 2 weeks). The pigs were dynamically PET...

  3. Magnetic resonance imaging perfusion is associated with disease severity and activity in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Sowa, Piotr [Oslo University Hospital, Department of Radiology and Nuclear Medicine, Oslo (Norway); University of Oslo, Institute of Clinical Medicine, Faculty of Medicine, Oslo (Norway); Owren Nygaard, Gro [Oslo University Hospital, Department of Neurology, Oslo (Norway); Bjoernerud, Atle [Intervention Center, Oslo University Hospital, Oslo (Norway); University of Oslo, Department of Physics, Oslo (Norway); Gulowsen Celius, Elisabeth [Oslo University Hospital, Department of Neurology, Oslo (Norway); University of Oslo, Institute of Health and Society, Faculty of Medicine, Oslo (Norway); Flinstad Harbo, Hanne [University of Oslo, Institute of Clinical Medicine, Faculty of Medicine, Oslo (Norway); Oslo University Hospital, Department of Neurology, Oslo (Norway); Kristiansen Beyer, Mona [Oslo University Hospital, Department of Radiology and Nuclear Medicine, Oslo (Norway); Oslo and Akershus University College of Applied Sciences, Department of Life Sciences and Health, Oslo (Norway)

    2017-07-15

    The utility of perfusion-weighted imaging in multiple sclerosis (MS) is not well investigated. The purpose of this study was to compare baseline normalized perfusion measures in subgroups of newly diagnosed MS patients. We wanted to test the hypothesis that this method can differentiate between groups defined according to disease severity and disease activity at 1 year follow-up. Baseline magnetic resonance imaging (MRI) including a dynamic susceptibility contrast perfusion sequence was performed on a 1.5-T scanner in 66 patients newly diagnosed with relapsing-remitting MS. From the baseline MRI, cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps were generated. Normalized (n) perfusion values were calculated by dividing each perfusion parameter obtained in white matter lesions by the same parameter obtained in normal-appearing white matter. Neurological examination was performed at baseline and at follow-up approximately 1 year later to establish the multiple sclerosis severity score (MSSS) and evidence of disease activity (EDA). Baseline normalized mean transit time (nMTT) was lower in patients with MSSS >3.79 (p = 0.016), in patients with EDA (p = 0.041), and in patients with both MSSS >3.79 and EDA (p = 0.032) at 1-year follow-up. Baseline normalized cerebral blood flow and normalized cerebral blood volume did not differ between these groups. Lower baseline nMTT was associated with higher disease severity and with presence of disease activity 1 year later in newly diagnosed MS patients. Further longitudinal studies are needed to confirm whether baseline-normalized perfusion measures can differentiate between disease severity and disease activity subgroups over time. (orig.)

  4. Magnetic resonance imaging perfusion is associated with disease severity and activity in multiple sclerosis

    International Nuclear Information System (INIS)

    Sowa, Piotr; Owren Nygaard, Gro; Bjoernerud, Atle; Gulowsen Celius, Elisabeth; Flinstad Harbo, Hanne; Kristiansen Beyer, Mona

    2017-01-01

    The utility of perfusion-weighted imaging in multiple sclerosis (MS) is not well investigated. The purpose of this study was to compare baseline normalized perfusion measures in subgroups of newly diagnosed MS patients. We wanted to test the hypothesis that this method can differentiate between groups defined according to disease severity and disease activity at 1 year follow-up. Baseline magnetic resonance imaging (MRI) including a dynamic susceptibility contrast perfusion sequence was performed on a 1.5-T scanner in 66 patients newly diagnosed with relapsing-remitting MS. From the baseline MRI, cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps were generated. Normalized (n) perfusion values were calculated by dividing each perfusion parameter obtained in white matter lesions by the same parameter obtained in normal-appearing white matter. Neurological examination was performed at baseline and at follow-up approximately 1 year later to establish the multiple sclerosis severity score (MSSS) and evidence of disease activity (EDA). Baseline normalized mean transit time (nMTT) was lower in patients with MSSS >3.79 (p = 0.016), in patients with EDA (p = 0.041), and in patients with both MSSS >3.79 and EDA (p = 0.032) at 1-year follow-up. Baseline normalized cerebral blood flow and normalized cerebral blood volume did not differ between these groups. Lower baseline nMTT was associated with higher disease severity and with presence of disease activity 1 year later in newly diagnosed MS patients. Further longitudinal studies are needed to confirm whether baseline-normalized perfusion measures can differentiate between disease severity and disease activity subgroups over time. (orig.)

  5. Experience of German Red Cross blood donor services with nucleic acid testing: results of screening more than 30 million blood donations for human immunodeficiency virus-1, hepatitis C virus, and hepatitis B virus.

    Science.gov (United States)

    Hourfar, Michael K; Jork, Christine; Schottstedt, Volkmar; Weber-Schehl, Marijke; Brixner, Veronika; Busch, Michael P; Geusendam, Geert; Gubbe, Knut; Mahnhardt, Christina; Mayr-Wohlfart, Uschi; Pichl, Lutz; Roth, W Kurt; Schmidt, Michael; Seifried, Erhard; Wright, David J

    2008-08-01

    The risk of transfusion-transmitted human immunodeficiency virus-1 (HIV-1), hepatitis C virus (HCV), and hepatitis B virus (HBV) infections is predominantly attributable to donations given during the early stage of infection when diagnostic tests may fail. In 1997, nucleic acid amplification technique (NAT)-testing was introduced at the German Red Cross (GRC) blood donor services to reduce this diagnostic window period (WP). A total of 31,524,571 blood donations collected from 1997 through 2005 were screened by minipool NAT, predominantly with pool sizes of 96 donations. These donations cover approximately 80 percent of all the blood collected in Germany during that period. Based on these data, the WP risk in the GRC blood donor population was estimated by using a state-of-the-art mathematic model. During the observation period, 23 HCV, 7 HIV-1, and 43 HBV NAT-only-positive donations were detected. On the basis of these data and estimated pre-NAT infectious WPs, the residual risk per unit transfused was estimated at 1 in 10.88 million for HCV (95% confidence interval [CI], 7.51-19.72 million), 1 in 4.30 million for HIV-1 (95% CI, 2.39-21.37 million), and 1 in 360,000 for HBV (95% CI, 0.19-3.36 million). Based on observed cases of breakthrough infections, the risk of transfusion-related infections may be even lower. The risk of a blood recipient becoming infected with HCV, HIV-1, or HBV has reached an extremely low level. Introduction of individual donation testing for HCV and HIV-1 would have a marginal effect on interception of WP donations.

  6. Brain perfusion imaging with iodinated amines

    International Nuclear Information System (INIS)

    Kung, H.F.

    1989-01-01

    Traditional nuclear medicine brain study using 99m Tc pertechnetate, glucoheptonate or diethlenetriaminepentacetic acid (DTPA) and planar imaging has experienced a significant decline in the past 10 years. This is mainly due to the introduction of X-ray CT and more recently the nuclear magnetic resonance (NMR) imaging, by which detailed morphology of the brain, including the detection of breakdown of the blood-brain barrier, can be obtained. The nuclear medicine brain imaging is only prescribed as a complementary test when X-ray CT is negative or equivocal and clinical suspicion remains. The attention of nuclear medicine brain imaging has been shifted from the detection of the breakdown of the blood-brain barrier to the study of brain function-perfusion, metabolism, and receptor binding, etc. The functional brain imaging provides diagnostic information usually unattainable by other radiological techniques. In this article, the iodinated amines as brain perfusion imaging agents are reviewed. Potential clinical application of these agents is discussed

  7. Hepatitis virus panel

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003558.htm Hepatitis virus panel To use the sharing features on this page, please enable JavaScript. The hepatitis virus panel is a series of blood tests used ...

  8. A study of whole brain perfusion CT and CT angiography in hyperacute and acute cerebral infarction

    International Nuclear Information System (INIS)

    Zhang Yonghai; Bai Junhu; Zhang Ming; Yang Guocai; Tang Guibo; Fang Jun; Shi Wei; Li Xinghua; Liu Suping; Lu Qing; Tang Jun

    2005-01-01

    Objective: To evaluate the diagnostic value of whole-brain perfusion blood volume-weighted CT imaging (PWCT) and simultaneous CT angiography (CTA) on early stage of cerebral ischemic infarction. Methods: Non-contrast CT (NCCT), CT perfusion-weighted imaging (PWCT) and delayed CT (DCT) were conducted on 20 cases of early ischemic infarction of whose onset time ranged from 2 to 24 hours. All cases were reexamined with CT or MRI one week to one month later. CT values and perfusion blood volume (PBV) of central and peripheral low perfusion areas as well as those of collateral side were measured. CTA was reconstructed with PWCT as source images to evaluate occlusion or stenosis of blood vessel, and DCT was used to detect the collateral circulation. Results: Of the 20 cases, NCCT, PWCT and CTA were negative in 10 cases in which 6 were confirmed as Transient Ischemic Attack (TIA) on reexamined CT and clinical features, and the other 4 were confirmed as lacunar infarction. For the remaining 10 cases, a comparison was made with ANOVA between low perfusion area (central, peripheral inside and outside) and collateral side. The difference was significant (P<0.01). However, no significant difference was revealed in the central, peripheral inside and outside areas. PBV values were significant in low perfusion area and collateral side (P<0.05). The area of the final infarction was larger than that of the low perfusion area, and the percentage of enlargement exhibited medium negative correlation to the time of ischemia. CTA indicated that 2 cases suffered from left middle cerebral artery occlusion, meanwhile anterior and middle branches of MCA in the other 3 cases were not identified. The sensitivity of NCCT, PWCT and CTA were 28.5%, 71.4% and 35.7% respectively. DCT indicated that 5 cases had asymmetrical blood vessels. Conclusion: The whole-brain perfusion-weighted CT imaging and simultaneous CT angiography (CTA) is p roved to be a simple, timesaving and effective method for the

  9. The influence of parenteral nitrogen feeding on free amino acid composition of blood serum and hepatic tissue of irradiated rats

    International Nuclear Information System (INIS)

    Mil'ko, V.I.; Kirichenko, A.V.; Chalaya, L.A.

    1985-01-01

    A considerable change in the free am ino acid composition of blood serum and hepatic tissued was noted on the 7th and 14th days following total-body X-irradiation of rats with a dose of 2.9 Gy. The total free amino acid content of blood serum increased and that of hepatic tissue decreased by 85% (on an average) as compared to the intact controls. Quantitative changes in the content of individual amino acids were analysed. Polyamine injected enterally for 7 days and parenterally for 3 days after irradiation a the elimination of the postirradiation changes in the amino acid balance

  10. Non invasive blood flow measurement in cerebellum detects minimal hepatic encephalopathy earlier than psychometric tests.

    Science.gov (United States)

    Felipo, Vicente; Urios, Amparo; Giménez-Garzó, Carla; Cauli, Omar; Andrés-Costa, Maria-Jesús; González, Olga; Serra, Miguel A; Sánchez-González, Javier; Aliaga, Roberto; Giner-Durán, Remedios; Belloch, Vicente; Montoliu, Carmina

    2014-09-07

    To assess whether non invasive blood flow measurement by arterial spin labeling in several brain regions detects minimal hepatic encephalopathy. Blood flow (BF) was analyzed by arterial spin labeling (ASL) in different brain areas of 14 controls, 24 cirrhotic patients without and 16 cirrhotic patients with minimal hepatic encephalopathy (MHE). Images were collected using a 3 Tesla MR scanner (Achieva 3T-TX, Philips, Netherlands). Pulsed ASL was performed. Patients showing MHE were detected using the battery Psychometric Hepatic Encephalopathy Score (PHES) consisting of five tests. Different cognitive and motor functions were also assessed: alterations in selective attention were evaluated using the Stroop test. Patients and controls also performed visuo-motor and bimanual coordination tests. Several biochemical parameters were measured: serum pro-inflammatory interleukins (IL-6 and IL-18), 3-nitrotyrosine, cGMP and nitrates+nitrites in plasma, and blood ammonia. Bivariate correlations were evaluated. In patients with MHE, BF was increased in cerebellar hemisphere (P = 0.03) and vermis (P = 0.012) and reduced in occipital lobe (P = 0.017). BF in cerebellar hemisphere was also increased in patients without MHE (P = 0.02). Bimanual coordination was impaired in patients without MHE (P = 0.05) and much more in patients with MHE (P battery and with CFF. BF in cerebellar hemisphere correlates with plasma cGMP and nitric oxide (NO) metabolites. BF in vermis cerebellar also correlates with NO metabolites and with 3-nitrotyrosine. IL-18 in plasma correlates with BF in thalamus and occipital lobe. Non invasive BF determination in cerebellum using ASL may detect MHE earlier than the PHES. Altered NO-cGMP pathway seems to be associated to altered BF in cerebellum.

  11. Cerebral blood volume imaging by flat detector computed tomography in comparison to conventional multislice perfusion CT

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Doerfler, Arnd; Deuerling-Zheng, Yu; Boese, Jan; Zellerhoff, Michael; Schwab, Stefan

    2011-01-01

    We tested the hypothesis that Flat Detector computed tomography (FD-CT) with intravenous contrast medium would allow the calculation of whole brain cerebral blood volume (CBV) mapping (FD-CBV) and would correlate with multislice Perfusion CT (PCT). Twenty five patients were investigated with FD-CBV and PCT. Correlation of the CBV maps of both techniques was carried out with measurements from six anatomical regions from both sides of the brain. Mean values of each region and the correlation coefficient were calculated. Bland-Altman analysis was performed to compare the two different imaging techniques. The image and data quality of both PCT and FD-CBV were suitable for evaluation in all patients. The mean CBV values of FD-CBV and PCT showed only minimal differences with overlapping standard deviation. The correlation coefficient was 0.79 (p < 0.01). Bland-Altman analysis showed a mean difference of -0.077 ± 0.48 ml/100 g between FD-CBV and PCT CBV measurements, indicating that FD-CBV values were only slightly lower than those of PCT. CBV mapping with intravenous contrast medium using Flat Detector CT compared favourably with multislice PCT. The ability to assess cerebral perfusion within the angiographic suite may improve the management of ischaemic stroke and evaluation of the efficacy of dedicated therapies. (orig.)

  12. Extended normothermic extracorporeal perfusion of isolated human liver after warm ischaemia: a preliminary report.

    Science.gov (United States)

    Bellomo, Rinaldo; Marino, Bruno; Starkey, Graeme; Fink, Michael; Wang, Bao Zhong; Eastwood, Glenn M; Peck, Leah; Young, Helen; Houston, Shane; Skene, Alison; Opdam, Helen; Jones, Robert

    2014-09-01

    Donation after circulatory death (DCD) livers are at markedly increased risk of primary graft dysfunction and biliary tract ischaemia. Normothermic extracorporeal liver perfusion (NELP) may increase the ability to transplant DCD livers and may allow their use for artificial extracorporeal liver support of patients with fulminant liver failure. We conducted two proof-of-concept experiments using human livers after DCD to assess the feasibility and functional efficacy of NELP over an extended period. We applied extracorporeal membrane oxygenation, parenteral nutrition, separate hepatic artery and portal vein perfusion and physiological perfusion pressures to two livers obtained after DCD. We achieved NELP and evidence of liver function (bile production, paracetamol removal and maintenance of normal lactate levels) in both livers; one for 24 hours and the other for 43 hours. Histological examination showed areas of patchy ischaemia but preserved biliary ducts and canaliculi. Our experiments justify further investigations of the feasibility and efficacy of extended DCD liver preservation by ex-vivo perfusion.

  13. CT perfusion study of neck lymph nodes

    International Nuclear Information System (INIS)

    Zhong Jin; Liu Jun; Hua Rui; Qiao Hui; Gong Yi

    2011-01-01

    Objective: To study the CT perfusion features of various lymph nodes in the neck. Methods: Dynamic perfusion CT scanning was performed in 83 neck lymph nodes proved by pathology, including tuberculosis lymph nodes, lymphoma and metastatic lymph nodes. The shapes, blood flow modes, and perfusion parameters of these lymph nodes were compared among 3 groups. Statistical analysis of L/T and CT perfusion parameters was performed by one-way ANOVA and LSD test. Results: The values of MTT of tuberculosis lymph nodes, lymphoma and metastatic lymph nodes were (28.13±5.08), (31.08±5.82), and (11.24±5.31) s, respectively. The MTT of metastatic lymph nodes was statistically lower than that of tuberculosis lymph nodes and lymphoma (P -1 · 100 g -1 , respectively. The values of BV were (24.68±2.84), (25.30±3.16), and (25.15± 8.81) ml·100 g -1 respectively. The values of TTP were (40.90±8.85), (40.67±6.45), and (40.98±6.62) s, respectively. There were no significant differences in L/T, BF, BV and TTP among tuberculosis lymph nodes, lymphoma and metastatic lymph nodes (P>0.05). Conclusion: CT perfusion, especially combination functional imaging with perfusion images may be helpful in judging the nature of neck lymph nodes. (authors)

  14. Parametric investigation of heating due to magnetic fluid hyperthermia in a tumor with blood perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Liangruksa, Monrudee [Department of Engineering Science and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia 24061 (United States); Ganguly, Ranjan [Department of Power Engineering, Jadavpur University, Kolkata 700098 (India); Puri, Ishwar K., E-mail: ikpuri@vt.ed [Department of Engineering Science and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia 24061 (United States)

    2011-03-15

    Magnetic fluid hyperthermia (MFH) is a cancer treatment that can selectively elevate the tumor temperature without significantly damaging the surrounding healthy tissue. Optimal MFH design requires a fundamental parametric investigation of the heating of soft materials by magnetic fluids. We model the problem of a spherical tumor and its surrounding healthy tissue that are heated by exciting a homogeneous dispersion of magnetic nanoparticles infused only into the tumor with an external AC magnetic field. The key dimensionless parameters influencing thermotherapy are the Peclet, Fourier, and Joule numbers. Analytical solutions for transient and steady hyperthermia provide correlations between these parameters and the portions of tumor and healthy tissue that are subjected to a threshold temperature beyond which they are damaged. Increasing the ratio of the Fourier and Joule numbers also increases the tumor temperature, but doing so can damage the healthy tissue. Higher magnetic heating is required for larger Peclet numbers due to the larger convection heat loss that occurs through blood perfusion. A comparison of the model predictions with previous experimental data for MFH applied to rabbit tumors shows good agreement. The optimal MFH conditions are identified based on two indices, the fraction I{sub T} of the tumor volume in which the local temperature is above a threshold temperature and the ratio I{sub N} of the damaged normal tissue volume to the tumor tissue volume that also lies above it. The spatial variation in the nanoparticle concentration is also considered. A Gaussian distribution provides efficacy while minimizing the possibility of generating a tumor hot spot. Varying the thermal properties of tumor and normal tissue alters I{sub T}and I{sub N} but the nature of the temperature distribution remains unchanged. - Research highlights: > Analytical model of magnetic fluid hyperthermia of tumor tissue perfused with magnetic nanoparticles that is surrounded

  15. Parametric investigation of heating due to magnetic fluid hyperthermia in a tumor with blood perfusion

    International Nuclear Information System (INIS)

    Liangruksa, Monrudee; Ganguly, Ranjan; Puri, Ishwar K.

    2011-01-01

    Magnetic fluid hyperthermia (MFH) is a cancer treatment that can selectively elevate the tumor temperature without significantly damaging the surrounding healthy tissue. Optimal MFH design requires a fundamental parametric investigation of the heating of soft materials by magnetic fluids. We model the problem of a spherical tumor and its surrounding healthy tissue that are heated by exciting a homogeneous dispersion of magnetic nanoparticles infused only into the tumor with an external AC magnetic field. The key dimensionless parameters influencing thermotherapy are the Peclet, Fourier, and Joule numbers. Analytical solutions for transient and steady hyperthermia provide correlations between these parameters and the portions of tumor and healthy tissue that are subjected to a threshold temperature beyond which they are damaged. Increasing the ratio of the Fourier and Joule numbers also increases the tumor temperature, but doing so can damage the healthy tissue. Higher magnetic heating is required for larger Peclet numbers due to the larger convection heat loss that occurs through blood perfusion. A comparison of the model predictions with previous experimental data for MFH applied to rabbit tumors shows good agreement. The optimal MFH conditions are identified based on two indices, the fraction I T of the tumor volume in which the local temperature is above a threshold temperature and the ratio I N of the damaged normal tissue volume to the tumor tissue volume that also lies above it. The spatial variation in the nanoparticle concentration is also considered. A Gaussian distribution provides efficacy while minimizing the possibility of generating a tumor hot spot. Varying the thermal properties of tumor and normal tissue alters I T and I N but the nature of the temperature distribution remains unchanged. - Research Highlights: →Analytical model of magnetic fluid hyperthermia of tumor tissue perfused with magnetic nanoparticles that is surrounded by healthy tissue

  16. Commercial software upgrades may significantly alter Perfusion CT parameter values in colorectal cancer

    International Nuclear Information System (INIS)

    Goh, Vicky; Shastry, Manu; Endozo, Raymondo; Groves, Ashley M.; Engledow, Alec; Peck, Jacqui; Reston, Jonathan; Wellsted, David M.; Rodriguez-Justo, Manuel; Taylor, Stuart A.; Halligan, Steve

    2011-01-01

    To determine how commercial software platform upgrades impact on derived parameters for colorectal cancer. Following ethical approval, 30 patients with suspected colorectal cancer underwent Perfusion CT using integrated 64 detector PET/CT before surgery. Analysis was performed using software based on modified distributed parameter analysis (Perfusion software version 4; Perfusion 4.0), then repeated using the previous version (Perfusion software version 3; Perfusion 3.0). Tumour blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) were determined for identical regions-of-interest. Slice-by-slice and 'whole tumour' variance was assessed by Bland-Altman analysis. Mean BF, BV and PS was 20.4%, 59.5%, and 106% higher, and MTT 14.3% shorter for Perfusion 4.0 than Perfusion 3.0. The mean difference (95% limits of agreement) were +13.5 (-44.9 to 72.0), +2.61 (-0.06 to 5.28), -1.23 (-6.83 to 4.36), and +14.2 (-4.43 to 32.8) for BF, BV, MTT and PS respectively. Within subject coefficient of variation was 36.6%, 38.0%, 27.4% and 60.6% for BF, BV, MTT and PS respectively indicating moderate to poor agreement. Software version upgrades of the same software platform may result in significantly different parameter values, requiring adjustments for cross-version comparison. (orig.)

  17. Opt-Out Panel Testing for HIV, Hepatitis B and Hepatitis C in an Urban Emergency Department: A Pilot Study.

    Directory of Open Access Journals (Sweden)

    Sarah O'Connell

    Full Text Available Studies suggest 2 per 1000 people in Dublin are living with HIV, the level above which universal screening is advised. We aimed to assess the feasibility and acceptability of a universal opt-out HIV, Hepatitis B and Hepatitis C testing programme for Emergency Department patients and to describe the incidence and prevalence of blood-borne viruses in this population.An opt-out ED blood borne virus screening programme was piloted from March 2014 to January 2015. Patients undergoing blood sampling during routine clinical care were offered HIV 1&2 antibody/antigen assay, HBV surface antigen and HCV antibody tests. Linkage to care where necessary was co-ordinated by the study team. New diagnosis and prevalence rates were defined as the new cases per 1000 tested and number of positive tests per 1000 tested respectively.Over 45 weeks of testing, of 10,000 patient visits, 8,839 individual patient samples were available for analysis following removal of duplicates. A sustained target uptake of >50% was obtained after week 3. 97(1.09%, 44(0.49% and 447(5.05% HIV, Hepatitis B and Hepatitis C tests were positive respectively. Of these, 7(0.08%, 20(0.22% and 58(0.66% were new diagnoses of HIV, Hepatitis B and Hepatitis C respectively. The new diagnosis rate for HIV, Hepatitis B and Hepatitis C was 0.8, 2.26 and 6.5 per 1000 and study prevalence for HIV, Hepatitis B and Hepatitis C was 11.0, 5.0 and 50.5 per 1000 respectively.Opt-out blood borne viral screening was feasible and acceptable in an inner-city ED. Blood borne viral infections were prevalent in this population and newly diagnosed cases were diagnosed and linked to care. These results suggest widespread blood borne viral testing in differing clinical locations with differing population demographic risks may be warranted.

  18. Glucose phosphorylation is not rate limiting for accumulation of glycogen from glucose in perfused livers from fasted rats

    International Nuclear Information System (INIS)

    Youn, J.H.; Ader, M.; Bergman, R.N.

    1989-01-01

    Incorporation of Glc and Fru into glycogen was measured in perfused livers from 24-h fasted rats using [6-3H]Glc and [U-14C]Fru. For the initial 20 min, livers were perfused with low Glc (2 mM) to deplete hepatic glycogen and were perfused for the following 30 min with various combinations of Glc and Fru. With constant Fru (2 mM), increasing perfusate Glc increased the relative contribution of Glc carbons to glycogen (7.2 +/- 0.4, 34.9 +/- 2.8, and 59.1 +/- 2.7% at 2, 10, and 20 mM Glc, respectively; n = 5 for each). During perfusion with substrate levels seen during refeeding (10 mM Glc, 1.8 mumol/g/min gluconeogenic flux from 2 mM Fru), Fru provided 54.7 +/- 2.7% of the carbons for glycogen, while Glc provided only 34.9 +/- 2.8%, consistent with in vivo estimations. However, the estimated rate of Glc phosphorylation was at least 1.10 +/- 0.11 mumol/g/min, which exceeded by at least 4-fold the glycogen accumulation rate (0.28 +/- 0.04 mumol of glucose/g/min). The total rate of glucose 6-phosphate supply via Glc phosphorylation and gluconeogenesis (2.9 mumol/g/min) exceeded reported in vivo rates of glycogen accumulation during refeeding. Thus, in perfused livers of 24-h fasted rats there is an apparent redundancy in glucose 6-phosphate supply. These results suggest that the rate-limiting step for hepatic glycogen accumulation during refeeding is located between glucose 6-phosphate and glycogen, rather than at the step of Glc phosphorylation or in the gluconeogenic pathway

  19. Detection of Hepatitis C virus RNA in peripheral blood mononuclear cells of patients with abnormal alanine transaminase in Ahvaz

    Directory of Open Access Journals (Sweden)

    M Makvandi

    2014-01-01

    Full Text Available Purpose: Hepatitis C virus (HCV is an important agent for chronic and acute hepatitis. Occult hepatitis C remains a major health problem worldwide. Patients with chronic occult HCV may progress to cirrhosis and hepatocellular carcinoma. The aim of this study was to determine prevalence of occult hepatitis C by IS-PCR-ISH (in situ PCR in situ hybridisation in the patients with abnormal ALT. Materials and Methods: The blood samples were taken from 53 patients including 17 females (32.1% and 36 (67.9% males who had abnormal alanine transaminase (ALT for more than 1 year. The mean ALT and aspartate transaminase (AST level were 41.02 ± 9.3 and 24.17 ± 7.3, respectively. The patients′ age were between 4 and 70-years old with mean age 38 ± 13. All the patients were negative for HCV antibody, HCV RNA and HBs Ag. The peripheral blood mononuclear cells (PBMC were separated with ficoll gradient from each blood sample, then the cells were fixed on slides by cold acetone and followed by IS-PCR-ISH for HCV RNA detection. Results: Seventeen (32% patients including 6 (11.3% females and 11 (20.7% males showed positive results for HCV RNA by in situ-PCR in situ hybridisation. Ten (18.8% positive cases were between 20 and 40-years old and 6 (11.3% positive patients were between 40 and 60 years old. Ten (19.6% patients who were positive for IS-PCR-ISH also had positive anti-HBc IgG and 7 (13.2% patients were negative for HBc-IgG. Conclusion: In the present study high rate of 32% occult hepatitis C were found among the patients with elevated ALT.

  20. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    International Nuclear Information System (INIS)

    Bair, H.J.; Platsch, G.; Wolf, F.; Guenter, E.; Becker, D.; Rupprecht, H.; Neumayer, H.H.

    1997-01-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [de

  1. A randomized, controlled, double-blind crossover study on the effects of 2-L infusions of 0.9% saline and plasma-lyte® 148 on renal blood flow velocity and renal cortical tissue perfusion in healthy volunteers.

    Science.gov (United States)

    Chowdhury, Abeed H; Cox, Eleanor F; Francis, Susan T; Lobo, Dileep N

    2012-07-01

    We compared the effects of intravenous infusions of 0.9% saline ([Cl] 154 mmol/L) and Plasma-Lyte 148 ([Cl] 98 mmol/L, Baxter Healthcare) on renal blood flow velocity and perfusion in humans using magnetic resonance imaging (MRI). Animal experiments suggest that hyperchloremia resulting from 0.9% saline infusion may affect renal hemodynamics adversely, a phenomenon not studied in humans. Twelve healthy adult male subjects received 2-L intravenous infusions over 1 hour of 0.9% saline or Plasma-Lyte 148 in a randomized, double-blind manner. Crossover studies were performed 7 to 10 days apart. MRI scanning proceeded for 90 minutes after commencement of infusion to measure renal artery blood flow velocity and renal cortical perfusion. Blood was sampled and weight recorded hourly for 4 hours. Sustained hyperchloremia was seen with saline but not with Plasma-Lyte 148 (P Blood volume changes were identical (P = 0.867), but there was greater expansion of the extravascular fluid volume after saline (P = 0.029). There was a significant reduction in mean renal artery flow velocity (P = 0.045) and renal cortical tissue perfusion (P = 0.008) from baseline after saline, but not after Plasma-Lyte 148. There was no difference in concentrations of urinary neutrophil gelatinase-associated lipocalin after the 2 infusions (P = 0.917). This is the first human study to demonstrate that intravenous infusion of 0.9% saline results in reductions in renal blood flow velocity and renal cortical tissue perfusion. This has implications for intravenous fluid therapy in perioperative and critically ill patients. NCT01087853.

  2. Effect of rumen-protected choline on performance, blood metabolites, and hepatic triacylglycerols of periparturient dairy cattle

    NARCIS (Netherlands)

    Zom, R.L.G.; Baal, van J.; Goselink, R.M.A.; Bakker, J.A.; Veth, M.J.; Vuuren, van A.M.

    2011-01-01

    The effects of a dietary supplement of rumen-protected choline on feed intake, milk yield, milk composition, blood metabolites, and hepatic triacylglycerol were evaluated in periparturient dairy cows. Thirty-eight multiparous cows were blocked into 19 pairs and then randomly allocated to either one

  3. CT perfusion imaging in the management of posterior reversible encephalopathy

    International Nuclear Information System (INIS)

    Casey, S.O.; McKinney, A.; Teksam, M.; Liu, H.; Truwit, C.L.

    2004-01-01

    A 13-year-old girl with a renal transplant presented with hypertension and seizures. CT and MRI demonstrated typical bilateral parietal, occipital and posterior frontal cortical and subcortical edema, thought to represent posterior reversible encephalopathy syndrome. The cause was presumed to be hypertension. Antihypertensive therapy was started, lowering of the blood pressure in the range of 110-120 mmHg systolic. However, stable xenon (Xe) CT perfusion imaging revealed ischemia within the left parietal occipital region. The antihypertensive was adjusted which increased both the systolic and diastolic blood pressure by 31 mm Hg. The patient was re-imaged with Xe CT and was found to have resolution of the ischemic changes within the left parietal occipital region. In this report, we present a case in which stable Xe CT was used to monitor the degree of cerebral perfusion and guide titration of antihypertensive therapy. Such brain perfusion monitoring may have helped to prevent infarction of our patient. (orig.)

  4. Glycopyrrolate abolishes the exercise-induced increase in cerebral perfusion in humans

    DEFF Research Database (Denmark)

    Seifert, Thomas; Fisher, James P; Young, Colin N

    2010-01-01

    Brain blood vessels contain muscarinic receptors that are important for cerebral blood flow (CBF) regulation, but whether a cholinergic receptor mechanism is involved in the exercise-induced increase in cerebral perfusion or affects cerebral metabolism remains unknown. We evaluated CBF and cerebral......(mean) during ergometer cycling (n = 8). Separate, randomized and counterbalanced trials were performed in control (no drug) conditions and following muscarinic cholinergic receptor blockade by glycopyrrolate. Glycopyrrolate increased resting heart rate from approximately 60 to approximately 110 beats min(-1...... abolished by glycopyrrolate (P important for the exercise-induced increase in cerebral perfusion without affecting the cerebral metabolic rate for oxygen....

  5. Evaluation of the vascular state of hepatic tumor with radioisotope angiography and blood pool scintigraphies (early and delayed)

    International Nuclear Information System (INIS)

    Aburano, Tamio; Tonami, Norihisa; Hisada, Kinichi

    1976-01-01

    Combined radioisotope examinations of hepatic tumors have been performed using α 1 -fetoprotein radioimmunoassay, radioisotope angiography of the liver, and some tumor positive imaging scintigraphies. However, with these methods, it is frequently impossible to differentiate metastatic cancers from benign focal lesions. Radioisotope angiography of the liver, and both early (5 min later)- and delayed (4 hours later) blood pool scintigraphies of the liver were done continuously after 10mCi of sup(99m)Tc-albumin intravenous injection, in cases of clearcut focal lesions on sup(99m)Tc-colloid liver scan. The relationships among these findings were examined. Four of seven cases with hepatoma and two of nine cases with metastatic cancer which had showed hypervascular findings on radioisotope angiogram showed clear blood pool activities in the area of focal defects on sup(99m)Tc-colloid scan although less than liver. On the other hand, none of hypovascular tumors on radioisotope angiogram showed blood pool activities. However, four hours later, in most malignant lesions, the lesion to liver activity ratio calculated from data processing system showed a much higher value than the ratio obtained 5 min later after injection, although two cases with benign focal lesions did not show such sequential change. The sequential evaluation of the vascular state of a hepatic tumor using radioisotope angiography and early-and delayed blood pool scintigraphies was supposed to be extremely useful for the elucidation of the nature of focal hepatic lesions on sup(99m)Tc-colloid scan, especially in differentiating hypovascular malignant- and benign lesions. (auth.)

  6. 13C MRS Studies of the Control of Hepatic Glycogen Metabolism at High Magnetic Fields

    Directory of Open Access Journals (Sweden)

    Corin O. Miller

    2017-06-01

    Full Text Available Introduction: Glycogen is the primary intracellular storage form of carbohydrates. In contrast to most tissues where stored glycogen can only supply the local tissue with energy, hepatic glycogen is mobilized and released into the blood to maintain appropriate circulating glucose levels, and is delivered to other tissues as glucose in response to energetic demands. Insulin and glucagon, two current targets of high interest in the pharmaceutical industry, are well-known glucose-regulating hormones whose primary effect in liver is to modulate glycogen synthesis and breakdown. The purpose of these studies was to develop methods to measure glycogen metabolism in real time non-invasively both in isolated mouse livers, and in non-human primates (NHPs using 13C MRS.Methods: Livers were harvested from C57/Bl6 mice and perfused with [1-13C] Glucose. To demonstrate the ability to measure acute changes in glycogen metabolism ex-vivo, fructose, glucagon, and insulin were administered to the liver ex-vivo. The C1 resonance of glycogen was measured in real time with 13C MRS using an 11.7T (500 MHz NMR spectrometer. To demonstrate the translatability of this approach, NHPs (male rhesus monkeys were studied in a 7 T Philips MRI using a partial volume 1H/13C imaging coil. NPHs were subjected to a variable IV infusion of [1-13C] glucose (to maintain blood glucose at 3-4x basal, along with a constant 1 mg/kg/min infusion of fructose. The C1 resonance of glycogen was again measured in real time with 13C MRS. To demonstrate the ability to measure changes in glycogen metabolism in vivo, animals received a glucagon infusion (1 μg/kg bolus followed by 40 ng/kg/min constant infusion half way through the study on the second study session.Results: In both perfused mouse livers and in NHPs, hepatic 13C-glycogen synthesis (i.e., monotonic increases in the 13C-glycogen NMR signal was readily detected. In both paradigms, addition of glucagon resulted in cessation of glycogen

  7. Liver Function in the Pig

    African Journals Online (AJOL)

    1974-06-12

    Jun 12, 1974 ... The assessment of function of the isolated perfused liver remains complex. Much of this problem relates to an inability to compare function in vitro with that in vivo, because of a lack of knowledge of hepatic blood flow. This article documents measurement of total hepatic and portal blood flow in vivo in pigs, ...

  8. Prevalence of hepatitis B, hepatitis C and human immunodeficiency ...

    African Journals Online (AJOL)

    Background. Hepatitis B virus (HBV), hepatitis C virus (HCV) and HIV are common blood-borne infections unevenly distributed across regions in Nigeria. Few population-based prevalence studies have been done in Nigeria. Objective. To determine the prevalence of HBV, HCV and HIV and risk factors for infection with ...

  9. Hemodynamic changes in liver measured by multi-imaging methods before and after transjugular intrahepatic portosystemic stent-shunt

    International Nuclear Information System (INIS)

    Huang Yonghui; Chen Wei; Li Jiaping; Zhuang Wenquan; Li Ziping; Yang Jianyong

    2007-01-01

    Objective: To evaluate hemodynamic changes in liver treated by transjugular intrahepatic portosystemic stent-shunt (TIPSS) with hepatic computed tomography (CT) perfusion, Doppler ultrasound and portal vein pressure measurement, as well as the correlation among these methods. Methods: Hepatic CT perfusion was performed in 9 cirrhotic patients one week before TIPSS and 72 hours after TIPSS. Intraoperative portal vein pressure was measured before and after portosystemic shunt establish. The follow- up hepatic CT perfusion were carried out in 3 cases at 3 months and 6 months postoperatively. The hemodynamic surveillance by Doppler ultrasound were performed in 48 hours and 3 months after TIPSS for 9 cases, and in 6 months after TIPSS for 6 cases. Two cases underwent venography and portal vein pressure measurement in 6 months after TIPSS treatment. Results: The mean of portal vein perfusion (PVP), total hepatic blood flow (THBF), hepatic perfusion index (HPI) and portal vein free pressure (PVFP) before TIPSS were (0.92 ± 0.18) ml·min·ml -1 , (1.28±0.17) ml·min -1 ·ml -1 , (28 ± 8)%, and (23.92±0.86) mmHg, respectively. In 72 hours after TIPSS, the mean of PVP, THBF, HPI and PVFP were (0.21 ± 0.15) ml·min -1 ·ml -1 , (0.74 ± 0.18) ml·min -1 ·ml -1 , (74±13)%, and (12.62±1.54) mm Hg, respectively. After treatment, the mean of PVP was (0.49±0.05) ml·min -1 ·ml -1 at 3 months and (0.57±0.03) ml·min -1 ·ml -1 at 6 months, respectively. There was negative correlation between PVP and PVFP before TIPSS (r= 0.678, P 0.05). Moreover, a significant correlation was found between the degree of portal vein pressure decrease and portal vein perfusion decrease (r=0.867, P 3 /s was not less than that of main portal vein (9.83±5.72) cm 3 /s until six months after treatment. Conclusion: The portal vein pressure obviously decreased after TIPSS, and meanwhile, most blood flow of portal vein passed through portosystemic stent shunt without liver parenchyma perfusion

  10. Spatial relationship between tumor perfusion and endogeneous glucose distribution

    International Nuclear Information System (INIS)

    Schroeder, T.; Larrier, N.; Viglianti, B.; Rabbani, Z.N.; Peltz, C.; Vujascovic, Z.; Dewhirst, M.W.

    2003-01-01

    Earlier studies detecting glucose in tissue and solid tumors by bioluminescence imaging suggested, that glucose distribution patterns may be spatially related to functional vascularity. The purpose of this study was to evaluate this relationship by comparing glucose distribution patterns as determined by bioluminescence imaging to perfusion patterns of endogeneous Hoechst 33342 in rats bearing mammary carcinomas. R 3230 mammary carcinoma cells have been implanted subcutaneously into 7 female Fischer 344 rats. Two months post implantation, after injection of Hoechst 33342 the tumors were removed and snap frozen to conserve metabolite levels. Concomitantly, blood was sampled from the animals for analysis of glucose concentrations using a micodialysis analyzer. Cryosections of the tumors have been prepared, and every slice has been analyzed for both, Hoechst binding by fluorescence microscopy, and for glucose distribution patterns using bioluminescence imaging. In many cases vascular structures could be retrieved by the spatial pattern of glucose distribution. In some cases however, higher glucose concentrations could be found independent from Hoechst signal. On the other hand, regions of high Hoechst signal are not necessarily correlated with high glucose concentrations. When comparing blood and tissue glucose levels, tissue glucose content as measured with bioluminescence imaging (1.9-3.5 mM) is considerably lower than blood glucose (5.6-8.0 mM), demonstrating the expected gradient from blood to tissue. This study demonstrates the feasibility of monitoring glucose gradients in relation to functional vasculature throughout the body, from blood down to tissue or tumor and further, throughout the microenvironment of the solid tumor. Glucose distribution patterns may be an important tool in perfusion studies, e. g. in detecting the direction of blood flow in ex-vivo samples or in estimating glucose consumption rates of tumor cells adjacent to or in between perfused

  11. Adsorption of viral particles from the blood plasma of patients with viral hepatitis on nanodiamonds.

    Science.gov (United States)

    Baron, A V; Osipov, N V; Yashchenko, S V; Kokotukha, Yu A; Baron, I J; Puzyr, A P; Olkhovskiy, I A; Bondar, V S

    2016-07-01

    Adsorption of viral particles from the blood plasma of patients with viral hepatitis B and C on modified nanodiamonds (MNDs) was shown in the in vitro experiments. PCR method showed the treatment of plasma with MNDs leads to a decrease in the viral load by 2-3 orders of magnitude or more in both cases studied. These results make it possible to predict the applicability of MNDs for the development of new technologies of hemodialysis and plasmapheresis for binding and removal of viral particles from the blood of infected patients.

  12. Outbreak of hepatitis E virus infection in Darfur, Sudan: effectiveness of real-time reverse transcription-PCR analysis of dried blood spots.

    Science.gov (United States)

    Mérens, Audrey; Guérin, Philippe Jean; Guthmann, Jean-Paul; Nicand, Elisabeth

    2009-06-01

    Biological samples collected in refugee camps during an outbreak of hepatitis E were used to compare the accuracy of hepatitis E virus RNA amplification by real-time reverse transcription-PCR (RT-PCR) for sera and dried blood spots (concordance of 90.6%). Biological profiles (RT-PCR and serology) of asymptomatic individuals were also analyzed.

  13. Regional cerebral blood flow during mechanical hyperventilation in patients with fulminant hepatic failure

    DEFF Research Database (Denmark)

    Strauss, Gitte Irene; Høgh, Peter; Møller, Kirsten

    1999-01-01

    Hyperventilation is frequently used to prevent or postpone the development of cerebral edema and intracranial hypertension in patients with fulminant hepatic failure (FHF). The influence of such therapy on regional cerebral blood flow (rCBF) remains, however, unknown. In this study the CBF......-distribution pattern was determined within the first 12 hours after development of hepatic encephalopathy (HE) stage 4 before and during hyperventilation. Ten consecutive patients (median age 48 [range 33-57] years) with FHF and 9 healthy controls (median age 54 [24-58] years) had rCBF determined by single photon...... emission computed tomography (SPECT) using intravenous injection of 133Xenon. For determination of high resolution CBF pattern, the patients were also studied with 99mTc-hexa-methylpropyleneamine oxime (HMPAO) in the hyperventilation condition. There was no significant difference in the rCBF distribution...

  14. Peripheral blood monocyte subsets predict antiviral response in chronic hepatitis C.

    Science.gov (United States)

    Rodríguez-Muñoz, Y; Martín-Vílchez, S; López-Rodríguez, R; Hernández-Bartolomé, A; Trapero-Marugán, M; Borque, M J; Moreno-Otero, R; Sanz-Cameno, P

    2011-10-01

    Hepatitis C virus infection evolves into chronic progressive liver disease in a significant percentage of patients. Monocytes constitute a diverse group of myeloid cells that mediate innate and adaptive immune response. In addition to proinflammatory CD16+ monocytes, a Tie-2+ subgroup - Tie-2 expressing monocytes (TEMs) - that has robust proangiogenic potential has been recently defined. To study the heterogeneity of peripheral blood monocytes in chronic hepatitis C (CHC) patients and to examine their proposed pathophysiological roles on disease progression and response to antiviral therapy. We studied CD16+ and Tie-2+ peripheral monocyte subpopulations in 21 healthy subjects and 39 CHC patients in various stages of disease and responses to antiviral treatment using flow cytometry. Expression profiles of proangiogenic and tissue remodelling factors in monocyte supernatants were measured using ELISA and protein arrays. Intrahepatic expression of CD14, CD31 and Tie-2 was analysed using immunofluorescence. Increases of certain peripheral monocyte subsets were observed in the blood of CHC patients, wherein those cells with proinflammatory (CD16+) or proangiogenic (TEMs) potential expanded (P TEMs were significantly increased in nonresponders, particularly those with lower CD16 expression. In addition, many angiogenic factors were differentially expressed by peripheral monocytes from control or CHC patients, such as angiopoietin-1 and angiogenin (P TEMs were distinguished within portal infiltrates of CHC patients. These findings suggest for the first time the relevance of peripheral monocytes phenotypes for the achievement of response to treatment. Hence, the study of monocyte subset regulation might effect improved CHC prognoses and adjuvant therapies. © 2011 Blackwell Publishing Ltd.

  15. Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cao Yue, E-mail: yuecao@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Wang Hesheng [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Johnson, Timothy D. [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Pan, Charlie [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Hussain, Hero [Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Normolle, Daniel; Ben-Josef, Edgar; Ten Haken, Randall K.; Lawrence, Theodore S.; Feng, Mary [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2013-01-01

    Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation between mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which

  16. Assessment of Cu-ETS as a PET radiopharmaceutical for evaluation of regional renal perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Green, Mark A. [Department of Industrial and Physical Pharmacy, Purdue University, West Lafayette, IN 47907 (United States)]. E-mail: magreen@purdue.edu; Mathias, Carla J. [Department of Industrial and Physical Pharmacy, Purdue University, West Lafayette, IN 47907 (United States); Willis, Lynn R. [Department of Pharmacology and Toxicology, Indiana University School of Medicine, Indianapolis, IN 46202 (United States); Handa, Rajash K. [Department of Pharmacology and Toxicology, Indiana University School of Medicine, Indianapolis, IN 46202 (United States); Lacy, Jeffrey L. [Proportional Technologies, Inc., Houston, TX 77054 (United States); Miller, Michael A. [Department of Radiology and the Indiana Center of Excellence in Biomedical Imaging, Indiana University School of Medicine, Indianapolis, IN 46202 (United States); Hutchins, Gary D. [Department of Radiology and the Indiana Center of Excellence in Biomedical Imaging, Indiana University School of Medicine, Indianapolis, IN 46202 (United States)

    2007-04-15

    The copper(II) complex of ethylglyoxal bis(thiosemicarbazone) (Cu-ETS) was evaluated as a positron emission tomography (PET) radiopharmaceutical for assessment of regional renal perfusion. Methods: The concordance of renal flow estimates obtained with 11- and 15-{mu}m microspheres was confirmed in four immature farm pigs using co-injected {sup 46}Sc- and {sup 57}Co-microspheres administered into the left ventricle. With the use of both immature farm pigs (n=3) and mature Goettingen minipigs (n=6), regional renal radiocopper uptake following intravenous [{sup 64}Cu]Cu-ETS administration was compared to microsphere measurements of renal perfusion. The distribution and kinetics of [{sup 64}Cu]Cu-ETS were further studied by PET imaging of the kidneys. The rate of [{sup 64}Cu]Cu-ETS decomposition by blood was evaluated in vitro, employing octanol extraction to recover intact [{sup 64}Cu]Cu-ETS. Results: The co-injected 11- and 15-{mu}m microspheres provided similar estimates of renal flow. A linear relationship was observed between the renal uptake of intravenous [{sup 64}Cu]Cu-ETS and regional renal perfusion measured using microspheres. [{sup 64}Cu]Cu-ETS provided high-quality PET kidney images demonstrating the expected count gradient from high-flow outer cortex to low-flow medulla. When incubated with pig blood in vitro at 37{sup o}C, the [{sup 64}Cu]Cu-ETS radiopharmaceutical was observed to decompose with a half-time of 2.8 min. Conclusion: Cu-ETS appears suitable for use as a PET radiopharmaceutical for evaluation of regional renal perfusion, affording renal uptake of radiocopper that varies linearly with microsphere perfusion measurements. Quantification of renal perfusion (in ml min{sup -1} g{sup -1}) with [{sup 60,61,62,64}Cu]Cu-ETS will require correcting the arterial input function for the fraction of blood radiocopper remaining present as the intact Cu-ETS radiopharmaceutical, since the Cu-ETS chelate has limited chemical stability in blood. Rapid octanol

  17. Relationship between hepatic CTGF expression and routine blood tests at the time of liver transplantation for biliary atresia: hope or hype for a biomarker of hepatic fibrosis.

    Science.gov (United States)

    Haafiz, Allah; Farrington, Christian; Andres, Joel; Islam, Saleem

    2011-01-01

    Progressive hepatic fibrosis (HF) is a prominent feature of biliary atresia (BA), the most common indication for liver transplantation (LT) in children. Despite its importance in BA, HF is not evaluated in routine patient care because the invasiveness of liver biopsy makes histologic monitoring of fibrosis unfeasible. Therefore, the identification of noninvasive markers to assess HF is desirable especially in children. The main goal of this pilot project was to establish an investigational framework correlating hepatic expression of fibrogenic markers with routine blood tests in BA. Using liver explants from patients with BA (n = 26), immune-expression of connective tissue growth factor (CTGF), a key fibrogenic cytokine was determined using horseradish-labeled antibodies. Expression intensities of lobular (L-CTGF) and portal (P-CTGF) CTGF were determined by using ImageJ software. These CTGF intensities were correlated with blood tests performed at the time of LT. Correlation coefficients were determined for each blood test variable versus mean L-CTGF and P-CTGF expression intensities. A P-value of less than 0.05 was considered statistically significant. All patients had end-stage liver disease and persistent cholestasis at the time of LT. Kendall tau (τ) rank correlation coefficient for L-CTGF and white blood cell (WBC) was inversed (-0.52; P ≤ 0.02). Similar but statistically nonsignificant inverse relationships were noted between L-CTGF and prothrombin time (PT) (-0.15; P ≤ 0.4), international normalized ratio (INR) (-0.14; P ≤ 0.5), and platelet count (-0.36; P ≤ 0.09). Inversed (τ) rank correlation coefficients were also evident between P-CTGF expression and gamma-glutamyl transpeptidase (GGT), PT, INR, and platelet count. Pearson correlation coefficients for combinational analysis of standardized total bilirubin (TB), alkaline phosphatase, GGT, and platelet count with L-CTGF (0.33; P = 0.3) and P-CTGF (0.06; P = 0.8), were not significant. Similar

  18. CT perfusion imaging in response assessment of pulmonary metastases undergoing stereotactic ablative radiotherapy

    International Nuclear Information System (INIS)

    Sawyer, Brooke; Pun, Emma; Tay, Huilee; Kron, Tomas; Bressel, Mathias; Ball, David; Siva, Shankar; Samuel, Michael

    2015-01-01

    Stereotactic ablative body radiotherapy (SABR) is an emerging treatment technique for pulmonary metastases in which conventional Response Evaluation Criteria in Solid Tumours (RECIST) may be inadequate. This study aims to assess the utility of CT perfusion imaging in response assessment of pulmonary metastases after SABR. In this ethics board-approved prospective study, 11 patients underwent a 26-Gy single fraction of SABR to pulmonary metastases. CT perfusion imaging occurred prior to and at 14 and 70 days post-SABR. Blood flow (mL/100 mL/min), blood volume (mL/100 mL), time to peak (seconds) and surface permeability (mL/100 mL/min), perfusion parameters of pulmonary metastases undergoing SABR, were independently assessed by two radiologists. Inter-observer variability was analysed. CT perfusion results were analysed for early response assessment comparing day 14 with baseline scans and for late response by comparing day 70 with baseline scans. The largest diameter of the pulmonary metastases undergoing SABR was recorded. Ten patients completed all three scans and one patient had baseline and early response assessment CT perfusion scans only. There was strong level of inter-observer agreement of CT perfusion interpretation with a median intraclass coefficient of 0.87 (range 0.20–0.98). Changes in all four perfusion parameters and tumour sizes were not statistically significant. CT perfusion imaging of pulmonary metastases is a highly reproducible imaging technique that may provide additional response assessment information above that of conventional RECIST, and it warrants further study in a larger cohort of patients undergoing SABR.

  19. Angiohepatogram in diffuse hepatic disease

    Energy Technology Data Exchange (ETDEWEB)

    Aburano, T; Suzuki, Y; Hisada, K [Kanazawa Univ. (Japan). School of Medicine; Matsudaira, M

    1975-10-01

    A region of interest angiohepatogram was obtained with intravenous injection of 10mCi of sup(99m)Tc-Sn-colloid and a data processing system. Furthermore, the ratio of hepatic arterial blood flow volume to total hepatic blood flow volume was calculated according to Ueda's method, and the correlation of this calculated ratio and the degree of extrahepatic distribution of sup(99m)Tc-Sn-colloid (spleen to liver, and bone marrow to liver activity ratio) was examined. Most cases of liver cirrhosis and Banti's syndrome showed the increased hepatic arterial blood flow ratio (liver cirrhosis: 43.5+-9.5%, Banti's syndrome 48.8+-4.9%) in contrast with 18.1+-4.6% in normal cases, and its ratio showed much higher values in the presence of portal hypertension manifestations (esophageal varix and ascites). The hepatic arterial blood flow ratio showed increased values in the case of markedly increased extrahepatic activity, e.g. liver cirrhosis, and the correlation of the ratio and extrahepatic activity degree of sup(99m)Tc-Sn-colloid was significant statistically. From these results, a region of interest angiohepatogram was supposed to be useful for the prediction of the hemodynamic change, as well as, the improvement of diagnostic accuracy with radioisotope in diffuse hepatic disease, especially liver cirrhosis. Moreover, the hemodynamic change of liver, especially the reduction of the effectivehepatic blood flow volume via the portal vein was considered to be closely concerned in the mechanism of increased extrahepatic activity of RI colloid in diffuse hepatic disease.

  20. Hepatic disposition of the acyl glucuronide 1-O-gemfibrozil-beta-D-glucuronide: effects of clofibric acid, acetaminophen, and acetaminophen glucuronide.

    Science.gov (United States)

    Sabordo, L; Sallustio, B C; Evans, A M; Nation, R L

    2000-10-01

    Glucuronidation of carboxylic acid compounds results in the formation of electrophilic acyl glucuronides. Because of their polarity, carrier-mediated hepatic transport systems play an important role in determining both intra- and extrahepatic exposure to these reactive conjugates. We have previously shown that the hepatic membrane transport of 1-O-gemfibrozil-beta-D-glucuronide (GG) is carrier-mediated and inhibited by the organic anion dibromosulfophthalein. In this study, we examined the influence of 200 microM acetaminophen, acetaminophen glucuronide, and clofibric acid on the disposition of GG (3 microM) in the recirculating isolated perfused rat liver preparation. GG was taken up by the liver, excreted into bile, and hydrolyzed within the liver to gemfibrozil, which appeared in perfusate but not in bile. Mean +/- S. D. hepatic clearance, apparent intrinsic clearance, hepatic extraction ratio, and biliary excretion half-life of GG were 10.4 +/- 1.4 ml/min, 94.1 +/- 17.9 ml/min, 0.346 +/- 0.046, and 30.9 +/- 4.9 min, respectively, and approximately 73% of GG was excreted into bile. At the termination of the experiment (t = 90 min), the ratio of GG concentrations in perfusate, liver, and bile was 1:35:3136. Acetaminophen and acetaminophen glucuronide had no effect on the hepatic disposition of GG, suggesting relatively low affinities of acetaminophen conjugates for hepatic transport systems or the involvement of multiple transport systems for glucuronide conjugates. In contrast, clofibric acid increased the hepatic clearance, extraction ratio, and apparent intrinsic clearance of GG (P clofibric acid glucuronide at the level of hepatic transport. However, the transporter protein(s) involved remains to be identified.

  1. Direct myocardial perfusion imaging in valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Soto, R.C.; Durante, M.L.; Villacorta, E.V.; Torres, J.F.; Monzon, O.P.

    1981-02-01

    Twenty two patients with rheumatic valvular heart disease - 21 having a history of heart failure - were studied using direct coronary injection of /sup 99m/Tc labelled MAA particles during the course of hemodynamic and arteriographic studies. Myocardial perfusion deficit patterns have been shown to be consistent or indicative of either patchy, regional or gross ischemia. In patients with history of documented heart failure 90% (18 cases) had ischemic perfusion deficit in the involved ventricle. We conclude that diminished myocardial blood flow is an important mechanism contributing to the development of heart failure.

  2. Direct myocardial perfusion imaging in valvular heart disease

    International Nuclear Information System (INIS)

    Soto, R.C.; Durante, M.L.; Villacorta, E.V.; Torres, J.F.; Monzon, O.P.

    1981-01-01

    Twenty two patients with rheumatic valvular heart disease - 21 having a history of heart failure - were studied using direct coronary injection of sup(99m)Tc labelled MAA particles during the course of hemodynamic and arteriographic studies. Myocardial perfusion deficit patterns have been shown to be consistent or indicative of either patchy, regional or gross ischemia. In patients with history of documented heart failure 90% (18 cases) had ischemic perfusion deficit in the involved ventricle. We conclude that diminished myocardial blood flow is an important mechanism contributing to the development of heart failure. (orig.) [de

  3. The effect of patent ductus arteriosus on pre-ductal and post-ductal perfusion index in preterm neonates.

    Science.gov (United States)

    Nitzan, Itamar; Hammerman, Cathy; Fink, Daniel; Nitzan, Meir; Koppel, Robert; Bromiker, Ruben

    2018-06-26

    The ductus arteriosus is a blood vessel that connects the pulmonary artery to the descending aorta during fetal life and generally undergoes spontaneous closure shortly after birth. In premature neonates it often fails to close (patent ductus arteriosus - PDA), which can result in diversion of a significant part of the left-ventricular cardiac output to the pulmonary circulation. This left-to-right shunt may result in significant increase of pulmonary blood flow and decrease of systemic perfusion (hemodynamically significant PDA - hsPDA), which may lead to severe neonatal morbidity. The study objective was to find the relationship between hsPDA and perfusion index (PI), a photoplethysmographic parameter, related to systemic perfusion. Approach. PI measures the relative systolic increase in tissue light absorption due to the systolic increase in the tissue blood volume. PI has been found to be directly related to tissue perfusion, and is therefore expected to be affected by hsPDA. Main results. PI was found to be higher in preterm neonates with hsPDA after first week of life, in comparison to those with closed DA, despite the lower systemic perfusion, probably due to reverse flow during diastole. Significance. In our study, perfusion index increased despite the lower systemic perfusion, indicating that in neonates with hsPDA, perfusion index is not necessarily a measure of perfusion. Nevertheless, PI can be used as a screening tool for suspicious PDA, in order to select a relatively small group of neonates for a more definitive examination by echocardiography, which is not suitable for universal screening. . © 2018 Institute of Physics and Engineering in Medicine.

  4. Acute volume expansion attenuates hyperthermia-induced reductions in cerebral perfusion during simulated hemorrhage

    DEFF Research Database (Denmark)

    Schlader, Zachary J; Seifert, Thomas; Wilson, Thad E

    2013-01-01

    Hyperthermia reduces the capacity to withstand a simulated hemorrhagic challenge, but volume loading preserves this capacity. This study tested the hypotheses that acute volume expansion during hyperthermia increases cerebral perfusion and attenuates reductions in cerebral perfusion during...... infusion while hyperthermic. Primary dependent variables were mean middle cerebral artery blood velocity (MCAvmean), serving as an index of cerebral perfusion; mean arterial pressure (MAP); and cardiac output (thermodilution). During baseline, hyperthermia reduced MCAvmean (P = 0.001) by 12 ± 9% relative...

  5. 13C and 31P NMR study of gluconeogenesis: utilization of 13C-labeled substrates by perfused liver from streptozotocin-diabetic and untreated rats

    International Nuclear Information System (INIS)

    Cohen, S.M.

    1987-01-01

    The metabolism of 13 C-labeled substrates was followed by 13 C and 31 P NMR in perfused liver from the streptozotocin-treated rat model of insulin-dependent diabetes. Comparison was made with perfused liver from untreated littermates, fasted either 24 or 12 h. The major routes of pyruvate metabolism were followed by a 13 C NMR approach that provided for the determination of the metabolic fate of several substances simultaneously. The rate of gluconeogenesis was 2-4-fold greater and β-hydroxybutyrate production was 50% greater in liver from the chronically diabetic rats as compared with the control groups. Large differences in the distribution of 13 C label in hepatic alanine were measured between diabetic and control groups. The biosyntheses of 13 C-labeled glutathione and N-carbamoylaspartate were monitored in time-resolved 13 C NMR spectra of perfused liver. Assignments for the resonances of glutathione and N-carbamoylaspartate were made with the aid of 13 C NMR studies of perchloric acid extracts of the freeze-clamped livers. 13 C NMR spectroscopy of the perfusates provided a convenient, rapid assay of the rate of oxidation of [2- 13 C]ethanol, the hepatic output of [2- 13 ]acetaldehyde, and the accumulation of [2- 13 C]acetate in the perfusate. By 31 P NMR spectroscopy, carbamoyl phosphate was measured in all diabetic livers and an unusual P,P'-diesterified pyrophosphate was observed in one-fourth of the diabetic livers examined. Neither of these phosphorylated metabolites was detected in control liver. Both 13 C and 31 P NMR were useful in defining changes in hepatic metabolism in experimental diabetes

  6. Hepatic resection and regeneration. Past and present

    International Nuclear Information System (INIS)

    Hatsuse, Kazuo

    2007-01-01

    Hepatic surgery has been performed on condition that the liver regenerates after hepatic resection, and the development of liver anatomy due to Glisson, Rex, and Couinaud has thrown light on hepatic surgery Understanding of feeding and drainage vessels became feasible for systemic hepatic resection; however, it seems to have been the most important problem to control the bleeding during hepatic resection. New types of devices such as cavitron ultrasonic surgical aspirator (CUSA) and Microwave coagulation were exploited to control blood loss during hepatic surgery. Pringle maneuver for exclusion feeding vessels of the liver and the decrease of central venous pressure during anesthesia enabled further decrease of blood loss. Nowadays, 3D-CT imaging may depict feeding and drainage vessels in relation to liver mass, and surgeons can simulate hepatic surgery in virtual reality before surgery, allowing hepatectomy to be performed without blood transfusion. Thus, hepatic resection has been a safe procedure, but there's been a significant research on how much of the liver can be resected without hepatic failure. A prediction scoring system based on ICGR15, resection rates, and age is mostly reliable in some criteria. Even if hepatectomy is performed with a good prediction score, the massive bleeding and associated infection may induce postoperative hepatic failure, while the criteria of postoperative hepatic failure have not yet established. Hepatic failure is supposed to be induced by the apoptosis of mature hepatocytes and necrosis originated from microcirculation disturbance of the liver. Prostaglandin E1 for the improvement of microcirculation, steroid for the inhibition of cytokines inducing apoptosis, and blood purification to exclude cytokines have been tried separately or concomitantly. New therapeutic approaches, especially hepatic regeneration from the stem cell, are expected. (author)

  7. Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran.

    Science.gov (United States)

    Mohammadali, Fatemeh; Pourfathollah, Aliakbar

    2014-07-01

    The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P blood group "A" and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low.

  8. Renal blood flow and oxygenation drive nephron progenitor differentiation.

    Science.gov (United States)

    Rymer, Christopher; Paredes, Jose; Halt, Kimmo; Schaefer, Caitlin; Wiersch, John; Zhang, Guangfeng; Potoka, Douglas; Vainio, Seppo; Gittes, George K; Bates, Carlton M; Sims-Lucas, Sunder

    2014-08-01

    During kidney development, the vasculature develops via both angiogenesis (branching from major vessels) and vasculogenesis (de novo vessel formation). The formation and perfusion of renal blood vessels are vastly understudied. In the present study, we investigated the regulatory role of renal blood flow and O2 concentration on nephron progenitor differentiation during ontogeny. To elucidate the presence of blood flow, ultrasound-guided intracardiac microinjection was performed, and FITC-tagged tomato lectin was perfused through the embryo. Kidneys were costained for the vasculature, ureteric epithelium, nephron progenitors, and nephron structures. We also analyzed nephron differentiation in normoxia compared with hypoxia. At embryonic day 13.5 (E13.5), the major vascular branches were perfused; however, smaller-caliber peripheral vessels remained unperfused. By E15.5, peripheral vessels started to be perfused as well as glomeruli. While the interior kidney vessels were perfused, the peripheral vessels (nephrogenic zone) remained unperfused. Directly adjacent and internal to the nephrogenic zone, we found differentiated nephron structures surrounded and infiltrated by perfused vessels. Furthermore, we determined that at low O2 concentration, little nephron progenitor differentiation was observed; at higher O2 concentrations, more differentiation of the nephron progenitors was induced. The formation of the developing renal vessels occurs before the onset of blood flow. Furthermore, renal blood flow and oxygenation are critical for nephron progenitor differentiation. Copyright © 2014 the American Physiological Society.

  9. Hepatic Shock Differential Diagnosis and Risk Factors: A Review Article.

    Science.gov (United States)

    Soleimanpour, Hassan; Safari, Saeid; Rahmani, Farzad; Nejabatian, Arezu; Alavian, Seyed Moayed

    2015-10-01

    Liver as an important organ has a vital role in physiological processes in the body. Different causes can disrupt normal function of liver. Factors such as hypo-perfusion, hypoxemia, infections and some others can cause hepatic injury and hepatic shock. Published research resources from 2002 to May 2015 in some databases (PubMed, Scopus, Index Copernicus, DOAJ, EBSCO-CINAHL, Science direct, Cochrane library and Google scholar and Iranian search database like SID and Iranmedex) were investigated for the present study. Different causes can lead to hepatic shock. Most of these causes can be prevented by early resuscitation and treatment of underlying factors. Hepatic shock is detected in ill patients, especially those with hemodynamic disorders. It can be prevented by early treatment of underlying disease. There is no definite treatment for hepatic shock and should be managed conservatively. Hepatic shock in patients can increase the mortality rate.

  10. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...... turbo-FLASH (fast low-angle shot) sequence and Gd-DTPA has been presented. Here, an extension of the model is presented taking into account fast and slow water exchange between the compartments, enabling the calculation of the unidirectional influx constant (Ki) for Gd-DTPA, the distribution volume...... of Gd-DTPA (lambda), the vascular blood volume (Vb), and the time delay through the coronary arteries (delta T). The model was evaluated by computer simulation and used on experimental results from seven healthy subjects. The results in the healthy volunteers for a region of interest placed...

  11. CT and MR perfusion can discriminate severe cerebral hypoperfusion from perfusion absence: evaluation of different commercial software packages by using digital phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Uwano, Ikuko; Kudo, Kohsuke; Sasaki, Makoto [Iwate Medical University, Advanced Medical Research Center, Morioka (Japan); Christensen, Soren [University of Melbourne, Royal Melbourne Hospital, Departments of Neurology and Radiology, Victoria (Australia); Oestergaard, Leif [Aarhus University Hospital, Department of Neuroradiology, Center for Functionally Integrative Neuroscience, DK, Aarhus C (Denmark); Ogasawara, Kuniaki; Ogawa, Akira [Iwate Medical University, Department of Neurosurgery, Morioka (Japan)

    2012-05-15

    Computed tomography perfusion (CTP) and magnetic resonance perfusion (MRP) are expected to be usable for ancillary tests of brain death by detection of complete absence of cerebral perfusion; however, the detection limit of hypoperfusion has not been determined. Hence, we examined whether commercial software can visualize very low cerebral blood flow (CBF) and cerebral blood volume (CBV) by creating and using digital phantoms. Digital phantoms simulating 0-4% of normal CBF (60 mL/100 g/min) and CBV (4 mL/100 g/min) were analyzed by ten software packages of CT and MRI manufacturers. Region-of-interest measurements were performed to determine whether there was a significant difference between areas of 0% and areas of 1-4% of normal flow. The CTP software detected hypoperfusion down to 2-3% in CBF and 2% in CBV, while the MRP software detected that of 1-3% in CBF and 1-4% in CBV, although the lower limits varied among software packages. CTP and MRP can detect the difference between profound hypoperfusion of <5% from that of 0% in digital phantoms, suggesting their potential efficacy for assessing brain death. (orig.)

  12. Quantitation of Brown Adipose Tissue Perfusion in Transgenic Mice Using Near-Infrared Fluorescence Imaging

    Directory of Open Access Journals (Sweden)

    Akira Nakayama

    2003-01-01

    Full Text Available Brown adipose tissue (BAT; brown fat is the principal site of adaptive thermogenesis in the human newborn and other small mammals. Of paramount importance for thermogenesis is vascular perfusion, which controls the flow of cool blood in, and warmed blood out, of BAT. We have developed an optical method for the quantitative imaging of BAT perfusion in the living, intact animal using the heptamethine indocyanine IR-786 and near-infrared (NIR fluorescent light. We present a detailed analysis of the physical, chemical, and cellular properties of IR-786, its biodistribution and pharmacokinetics, and its uptake into BAT. Using transgenic animals with homozygous deletion of Type II iodothyronine deiodinase, or homozygous deletion of uncoupling proteins (UCPs 1 and 2, we demonstrate that BAT perfusion can be measured noninvasively, accurately, and reproducibly. Using these techniques, we show that UCP 1/2 knockout animals, when compared to wild-type animals, have a higher baseline perfusion of BAT but a similar maximal response to β3-receptor agonist. These results suggest that compensation for UCP deletion is mediated, in part, by the control of BAT perfusion. Taken together, BAT perfusion can now be measured noninvasively using NIR fluorescent light, and pharmacological modulators of thermogenesis can be screened at relatively high throughput in living animals.

  13. Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results

    International Nuclear Information System (INIS)

    Fink, C.; Buhmann, R.; Plathow, C.; Puderbach, M.; Kauczor, H.U.; Risse, F.; Ley, S.; Meyer, F.J.

    2004-01-01

    Purpose: to assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. Materials and methods: eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 ; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. Results: patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104-322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). Conclusion: time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease. (orig.) [de

  14. Dynamic infrared thermography (DIRT) for assessment of skin blood perfusion in cranioplasty: a proof of concept for qualitative comparison with the standard indocyanine green video angiography (ICGA).

    Science.gov (United States)

    Rathmann, P; Chalopin, C; Halama, D; Giri, P; Meixensberger, J; Lindner, D

    2018-03-01

    Complications in wound healing after neurosurgical operations occur often due to scarred dehiscence with skin blood perfusion disturbance. The standard imaging method for intraoperative skin perfusion assessment is the invasive indocyanine green video angiography (ICGA). The noninvasive dynamic infrared thermography (DIRT) is a promising alternative modality that was evaluated by comparison with ICGA. The study was carried out in two parts: (1) investigation of technical conditions for intraoperative use of DIRT for its comparison with ICGA, and (2) visual and quantitative comparison of both modalities in a proof of concept on nine patients. Time-temperature curves in DIRT and time-intensity curves in ICGA for defined regions of interest were analyzed. New perfusion parameters were defined in DIRT and compared with the usual perfusion parameters in ICGA. The visual observation of the image data in DIRT and ICGA showed that operation material, anatomical structures and skin perfusion are represented similarly in both modalities. Although the analysis of the curves and perfusion parameter values showed differences between patients, no complications were observed clinically. These differences were represented in DIRT and ICGA equivalently. DIRT has shown a great potential for intraoperative use, with several advantages over ICGA. The technique is passive, contactless and noninvasive. The practicability of the intraoperative recording of the same operation field section with ICGA and DIRT has been demonstrated. The promising results of this proof of concept provide a basis for a trial with a larger number of patients.

  15. Perfusion MRI in CNS disease: current concepts

    International Nuclear Information System (INIS)

    Essig, M.; Giesel, F.; Le-Huu, M.; Stieltjes, B.; Tengg, H. von; Weber, M.-A.

    2004-01-01

    Today there are several indications for cerebral perfusion MRI. The major indications routinely used in increasing numbers of imaging centers include cerebrovascular disease, tumor imaging and recently psychiatric disorders. Perfusion MRI is based on the injection of a gadolinium chelate and the rapid acquisition of images as the bolus of contrast agent passes through the blood vessels in the brain. The contrast agent causes a signal change; this signal change over time can be analysed to measure cerebral hemodynamics. The quality of brain perfusion studies is very dependent on the contrast agent used: a robust and strong signal decrease with a compact bolus is needed. MultiHance (gadobenate dimeglumine, Gd-BOPTA) is the first of a new class of paramagnetic MR contrast agents with a weak affinity for serum proteins. Due to the interaction of Gd-BOPTA with serum albumin, MultiHance presents with significantly higher T1- and T2-relaxivities enabling a sharper bolus profile. This article reviews the indications of perfusion MRI and the performance of MultiHance in MR perfusion of different diseases. Previous studies using perfusion MRI for a variety of purposes required the use of double dose of contrast agent to achieve a sufficiently large signal drop to enable the acquisition of a clear input function and the calculation of perfusion rCBV and rCBF maps of adequate quality. Recent studies with Multi-Hance suggest that only a single dose of this agent is needed to cause a signal drop of about 30% which is sufficient to allow the calculation of high quality rCBV and rCBF maps. (orig.)

  16. Embolization of Hepatic Arterial Branches to Simplify Hepatic Blood Flow Before Yttrium 90 Radioembolization: A Useful Technique in the Presence of Challenging Anatomy

    International Nuclear Information System (INIS)

    Karunanithy, Narayan; Gordon, Fabiana; Hodolic, Marina; Al-Nahhas, Adil; Wasan, Harpreet S.; Habib, Nagy; Tait, Nicholas P.

    2011-01-01

    = 0.004) for left lobe lesions. Conclusion: Selective Y90 radioembolization after manipulation of hepatic arterial blood supply leads to an even distribution within the entire liver. When variations in hepatic arterial anatomy exist, this technique allows effective whole-liver radioembolization therapy from a single selective arterial injection.

  17. Carotid artery disease and low cerebral perfusion pressure

    DEFF Research Database (Denmark)

    Schroeder, T; Utzon, N P; Aabech, J

    1990-01-01

    Direct internal carotid artery blood pressure measurements in patients undergoing carotid endarterectomy identified 49 patients, among 239 consecutive cases (21%), who had a reduction in perfusion pressure of 20% or more. The clinical history, objective findings and angiographic data were compared...

  18. Perfusion CT assessment of the colon and rectum: Feasibility of quantification of bowel wall perfusion and vascularization

    International Nuclear Information System (INIS)

    Khan, Sairah; Goh, Vicky; Tam, Emily; Wellsted, David; Halligan, Steve

    2012-01-01

    The aim was to determine the feasibility of vascular quantification of the bowel wall for different anatomical segments of the colorectum. Following institutional ethical approval and informed consent, 39 patients with colorectal cancer underwent perfusion CT. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface area product (PS) were assessed for different segments of the colorectum: ascending, transverse, descending colon, sigmoid, or rectum, that were distant from the tumor, and which were proven normal on contemporary colonoscopy, and subsequent imaging and clinical follow up. Mean (SD) for BF, BV, MTT and PS for the different anatomical colorectal segments were obtained and compared using a pooled t-test. Significance was at 5%. Assessment was not possible in 9 of 39 (23%) patients as the bowel wall was ≤5 mm precluding quantitative analysis. Forty-four segments were evaluated in the remaining 30 patients. Mean BF was higher in the proximal than distal colon: 24.0 versus 17.8 mL/min/100 g tissue; p = 0.009; BV, MTT and PS were not significantly different; BV: 3.46 versus 3.15 mL/100 g tissue, p = 0.45; MTT: 15.1 versus 18.3 s; p = 0.10; PS: 6.84 versus 8.97 mL/min/100 tissue, p = 0.13, respectively. In conclusion, assessment of bowel wall perfusion may fail in 23% of patients. The colorectum demonstrates segmental differences in perfusion.

  19. Pre-donation screening of volunteer prisoner blood donors for hepatitis B and C in prisons of punjab pakistan

    International Nuclear Information System (INIS)

    Pervaiz, A.; Sipra, F.S.; Rana, T.H.; Qadeer, I.

    2015-01-01

    Prisoners as a high risk group are never recommended for blood donations. In Pakistan, prisoners are legally allowed to donate blood and get thirty days extra remission. Inspectorate of prisons allowed Alizaib Foundation for blood donation camps subject to pre-donation screening of volunteer prisoner blood donor against infectious diseases. This study was conducted to identify the potential benefits of pre-donation screening. Methods: This cross sectional study was conducted in October, 2009 in Punjab. Intending volunteer prisoner blood donors from January, 2007 to September, 2009 from prisons of Punjab were included. Physically fit were tested for Hepatitis C Virus (HCV) and B Virus (HBV) by Rapid test kit before bleeding. Data was analysed by Epi-Info. Results: A total of 5894 male volunteer prisoner donors were screened and 1038 (17.6%) were rejected. The mean age was 28 years (range: 17-70 years). Of 5894, 857 (14.5%) were HCV positive and 222 (3.8%) were HBV positive. HCV and HBV co-infection was present among 41 (0.7%). Being convicted prisoner blood donor is significantly associated with higher seroprevalence for HCV (OR 1.35, 95% C.I. 1.17-1.57) and being under trial prisoner is significantly associated with higher seroprevalence for HBV (OR 1.40, 95% C.I. 1.06-1.85). Conclusion: Hepatitis B and C viruses were responsible for almost 18% prisoner blood donor rejection. Pre-donation screening of blood donors is an effective intervention to improve the safety and limit the cost of blood. Treatment of identified cases may contribute to public health. In the international scenario this study findings necessitate the amendments in the relevant prison rules. (author)

  20. Evaluating optimal superficial limb perfusion at different angles using non-invasive micro-lightguide spectrophotometry.

    Science.gov (United States)

    Darmanin, Geraldine; Jaggard, Matthew; Hettiaratchy, Shehan; Nanchahal, Jagdeep; Jain, Abhilash

    2013-06-01

    It is common practice to elevate the limbs postoperatively to reduce oedema and hence optimise perfusion and facilitate rehabilitation. However, elevation may be counterproductive as it reduces the mean perfusion pressure. There are no clear data on the optimal position of the limbs even in normal subjects. The optimal position of limbs was investigated in 25 healthy subjects using a non-invasive micro-lightguide spectrophotometry system "O2C", which indirectly measures skin and superficial tissue perfusion through blood flow, oxygen saturation and relative haemoglobin concentration. We found a reduction in skin and superficial tissue blood flow of 17% (p=0.0001) on arm elevation (180° shoulder flexion) as compared to heart level and an increase in skin and superficial tissue blood flow of 25% (p=0.02) on forearm elevation of 45°. Lower limb skin and superficial tissue blood flow decreased by 15% (p=0.004) on elevation to 47 cm and by 70% on dependency (p=0.0001) compared to heart level. However, on elevation of the lower limb there was also a 28% reduction in superficial venous pooling (p=0.0001) compared to heart level. In the normal limb, the position for optimal superficial perfusion of the upper limb is with the arm placed at heart level and forearm at 45°. In the lower limb the optimal position for superficial perfusion would be at heart level. However, some degree of elevation may be useful if there is an element of venous congestion. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Large-Animal Biventricular Working Heart Perfusion System with Low Priming Volume-Comparison between in vivo and ex vivo Cardiac Function.

    Science.gov (United States)

    Abicht, Jan-Michael; Mayr, Tanja Axinja Jelena; Jauch, Judith; Guethoff, Sonja; Buchholz, Stefan; Reichart, Bruno; Bauer, Andreas

    2018-01-01

    Existing large-animal, ex vivo, cardiac perfusion models are restricted in their ability to establish an ischemia/reperfusion condition as seen in cardiac surgery or transplantation. Other working heart systems only challenge one ventricle or require a substantially larger priming volume. We describe a novel biventricular cardiac perfusion system with reduced priming volume. Juvenile pig hearts were cardiopleged, explanted, and reperfused ex vivo after 150 minutes of cold ischemia. Autologous whole blood was used as perfusate (minimal priming volume 350 mL). After 15 minutes of Langendorff perfusion (LM), the system was switched into a biventricular working mode (WM) and studied for 3 hours. During reperfusion, complete unloading of both ventricles and constant-pressure coronary perfusion was achieved. During working mode perfusion, the preload and afterload pressure of both ventricles was controlled within the targeted physiologic range. Functional parameters such as left ventricular work index were reduced in ex vivo working mode (in vivo: 787 ± 186 vs. 1 h WM 498 ± 66 mm Hg·mL/g·min; p  hours while functional and blood parameters are easily accessible. Moreover, because of the minimal priming volume, the novel ex vivo cardiac perfusion circuit allows for autologous perfusion, using the limited amount of blood available from the organ donating animal. Georg Thieme Verlag KG Stuttgart · New York.

  2. Copper and ceruloplasmin contents in the blood serum of peripheral and pre-hepatic veins

    Directory of Open Access Journals (Sweden)

    H. M. Canelas

    1976-03-01

    Full Text Available Copper and ceruloplasmin contents were determined in samples of peripheral and pre-hepatic venous blood of 11 patients with Manson's schistosomiasis and one patient with hepatolenticular degeneration, all of çhich submitted either to porto-caval or spleno-renal shunt. Individual difference were not significant in any of the non-Wilsonian patients. The results are discussed in regard to the current knowledge on the pathogenesis of Wilson's disease.

  3. Local cortical hypoperfusion imaged with CT perfusion during postictal Todd's paresis

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, Marlon S.; Binder, Devin K. [University of California, Department of Neurological Surgery, Irvine, CA (United States); Smith, Wade S. [University of California, Department of Neurology, San Francisco, CA (United States); Wintermark, Max; Dillon, William P. [University of California, Department of Radiology, San Francisco, CA (United States)

    2008-05-15

    Postictal ('Todd's') paralysis, or 'epileptic hemiplegia,' is a well-known complication of focal or generalized epileptic seizures. However, it is unclear whether the pathophysiology of Todd's paralysis is related to alterations in cerebral perfusion. We report CT perfusion findings in a patient presenting with postictal aphasia and right hemiparesis. A 62-year-old woman with a history of alcohol abuse, closed head injury and posttraumatic epilepsy, presented with acute onset aphasia and right hemiparesis. A non-contrast head CT scan demonstrated no acute hemorrhage. Left hemispheric ischemia was suspected, and the patient was considered for acute thrombolytic therapy. MRI revealed a subtle increase in signal intensity involving the left medial temporal, hippocampal and parahippocampal regions on both T2-weighted FLAIR and diffusion-weighted sequences. CT angiography and CT perfusion study were performed. The CT perfusion study and CT angiography demonstrated a dramatic reduction in cerebral blood flow and blood volume involving the entire left hemisphere, but with relative symmetry of mean transit time, ruling out a large vessel occlusion. Clinical resolution of the aphasia and hemiparesis occurred within a few hours, and correlated with normalization of perfusion to the left hemisphere (detected by MR perfusion). This unique case is the first in which clinical evidence of Todd's paralysis has been correlated with reversible postictal hemispheric changes on CT and MR perfusion studies. This is important because CT perfusion study is being used more and more in the diagnosis of acute stroke, and one needs to be careful to not misinterpret the data. (orig.)

  4. Extrahepatic portal hypertension in childhood. Portographic findings and evaluation of hepatic blood flow by computerized radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-05-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood.

  5. Simulation evaluation of quantitative myocardial perfusion assessment from cardiac CT

    Science.gov (United States)

    Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.

    2014-03-01

    Contrast enhancement on cardiac CT provides valuable information about myocardial perfusion and methods have been proposed to assess perfusion with static and dynamic acquisitions. There is a lack of knowledge and consensus on the appropriate approach to ensure 1) sufficient diagnostic accuracy for clinical decisions and 2) low radiation doses for patient safety. This work developed a thorough dynamic CT simulation and several accepted blood flow estimation techniques to evaluate the performance of perfusion assessment across a range of acquisition and estimation scenarios. Cardiac CT acquisitions were simulated for a range of flow states (Flow = 0.5, 1, 2, 3 ml/g/min, cardiac output = 3,5,8 L/min). CT acquisitions were simulated with a validated CT simulator incorporating polyenergetic data acquisition and realistic x-ray flux levels for dynamic acquisitions with a range of scenarios including 1, 2, 3 sec sampling for 30 sec with 25, 70, 140 mAs. Images were generated using conventional image reconstruction with additional image-based beam hardening correction to account for iodine content. Time attenuation curves were extracted for multiple regions around the myocardium and used to estimate flow. In total, 2,700 independent realizations of dynamic sequences were generated and multiple MBF estimation methods were applied to each of these. Evaluation of quantitative kinetic modeling yielded blood flow estimates with an root mean square error (RMSE) of ~0.6 ml/g/min averaged across multiple scenarios. Semi-quantitative modeling and qualitative static imaging resulted in significantly more error (RMSE = ~1.2 and ~1.2 ml/min/g respectively). For quantitative methods, dose reduction through reduced temporal sampling or reduced tube current had comparable impact on the MBF estimate fidelity. On average, half dose acquisitions increased the RMSE of estimates by only 18% suggesting that substantial dose reductions can be employed in the context of quantitative myocardial

  6. Quantitative myocardial blood flow with Rubidium-82 PET

    DEFF Research Database (Denmark)

    Hagemann, Christoffer E; Ghotbi, Adam A; Kjær, Andreas

    2015-01-01

    Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1) identificat......Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1...... global MFR and major adverse cardiovascular events (MACE), and together with new diagnostic possibilities from measuring the longitudinal myocardial perfusion gradient, cardiac (82)Rb PET faces a promising clinical future. This article reviews current evidence on quantitative (82)Rb PET's ability...

  7. Dialyzer-augmented whole blood and plasma exchange for patients with hepatic or hepatorenal failure.

    Science.gov (United States)

    Buselmeier, T J; Merino, G E; Rodrigo, F; Meyer, R M; Bosl, B H; Kjellstrand, C M; Simmons, R L; Najarian, J S

    1975-01-01

    We have utilized new methods of dialyzer-augmented whole blood and plasma exchange tranfusion in the treatment of hepatic coma. The method employs the new fast flow Buselmeier shunt so that the exchange can be done from a peripheral radial artery shunt site rather than a shunt site in a more major vessel, such as the brachial artery. The method employs in-line dialysis of citrated (CPD) blood or plasma to normalize pH, electrolytes, and blood sugar while infusion heparinization decreases heparin requirements. The application of a single roller pump to the administration and withdrawal lines (placed in opposite directions) helps equalize inflow and outflow where whole blood exchange is done while identical opposing pumps accomplish the same with plasma exchange. The administration of albumin and metaraminol bitartate prevents hypotension due to fluid shifts or compartmental venous dilatation. A closed circuit which does not require disconnection throughout the 30- 60-minute whole blood exchange or the 2 1/2-hour plasma exchange decreases the risk of septic contamination to both medical staff and patients.

  8. Radionuclide method for blood volume determination in kidneys

    International Nuclear Information System (INIS)

    Trindev, P.; Nikolov, D.; Shejretova, E.; Garcheva-Tsacheva, M.

    1989-01-01

    The method is applied in nephrology for diagnosing changes in blood circulation of the kidneys. The blood volume of each kidney is determined separately by perfusion angioscintigraphy (PAS) with improved accuracy. The method consists in intravenous injection of 300-450 MBq 99m Tc for in-vivo labelling of the erythrocytes. About 30 images are registered every 2 sec, and through zones of interest perfusion histograms of kidneys are derived. Ten minutes later kidneys images (one full-face and two profiles) are registered. Correction coefficients for kidneys depth are derived and the activities registered according to full-face images and amplitudes of perfusion histograms are corrected. The activity of 1 ml blood is determined from blood sample of the patient. The blood volume of each kidney is expressed as a ratio of the activity corrected for background and depth and the activity of 1 ml blood of the sample. 1 claim

  9. Effect of obstructive jaundice on hepatic hemodynamics: use of Sonazoid-enhanced ultrasonography in a prospective study of the blood flow balance between the hepatic portal vein and hepatic artery.

    Science.gov (United States)

    Wakui, Noritaka; Takeda, Yuki; Nishinakagawa, Shuta; Ueki, Nobuo; Otsuka, Takafumi; Oba, Nobuyuki; Hashimoto, Hiroshi; Kamiyama, Naohisa; Sumino, Yasukiyo; Kojima, Tatsuya

    2015-10-01

    To prospectively clarify the effects of obstructive jaundice (OJ) on hepatic hemodynamics using contrast-enhanced ultrasonography (US). Subjects comprised 14 patients admitted to our hospital for OJ between April 2013 and March 2014. Contrast-enhanced US was performed using the LOGIQ E9 ultrasound device during the jaundice phase, before biliary drainage, and again after improvement of jaundice. After injecting the Sonazoid contrast agent, contrast dynamics were recorded in the right kidney and liver segments 5 or 6. Prototype software was used to calculate mean arrival time (AT) of the contrast agent in the liver parenchyma. Statistical analysis was performed to compare the mean AT in the jaundice and improved jaundice phases. We were unable to follow up three of the 14 patients after biliary drainage; thus, we included 11 patients for further analysis. The mean AT of the contrast agent was 2.0 ± 1.8 and 6.1 ± 2.3 s in the jaundice and improved jaundice phases, respectively, showing significantly shorter AT in the jaundice phase (p = 0.0033). Our findings indicate that OJ may influence the blood flow balance between the hepatic portal vein and hepatic artery.

  10. Sildenafil improves blood perfusion in steroid-induced avascular necrosis of femoral head in rabbits via a protein kinase G-dependent mechanism.

    Science.gov (United States)

    Song, Qichun; Ni, Jianlong; Jiang, Hongyuan; Shi, Zhibin

    2017-10-01

    The aim of the study were to evaluate the effect of sildenafil against avascular necrosis of femoral head (ANFH) in a rabbit model, and to study the role of protein kinase G (PKG) pathway and vascular endothelial growth factor (VEGF) in ANFH. Three weeks after inducing ANFH with methylprednisolone injection, 45 female adult New Zealand white rabbits were divided into three groups and treated as follows: group SI received daily intraperitoneal sildenafil with a dose of 10 mg/kg per day; group SD received daily sildenafil identically to group SI plus auricular vein injection DT3 (a specific PKG inhibitor); group NS received only normal saline. The blood perfusion function in the femoral head was measured by perfusion MRI and ink artery infusion. Bilateral femora heads were examined histopathologically for the presence of osteonecrosis; VEGF of tissue was examined by Western blot analysis; cGMP level and PKG activity were also measured. The incidence of ANFH in SI group was significantly lower than that observed in NS and SD groups (p < 0.05). VEGF in SI group was increased compared to NS group. cGMP level and PKG activity were also significantly different between NS and SI group (p < 0.05). However, these effects of sildenafil in SD group were all markedly inhibited by the administration of DT3 compared to SI group. Sildenafil appear to increase the perfusion of femoral head by up-regulating VEGF through PKG pathway. The increased perfusion of femoral head could prevent ANFH. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  11. No oxygen delivery limitation in hepatic encephalopathy

    DEFF Research Database (Denmark)

    Gjedde, Albert; Keiding, Susanne; Vilstrup, Hendrik

    2010-01-01

    to choose between cause and effect in three groups of volunteers, including healthy control subjects (HC), patients with cirrhosis of the liver without hepatic encephalopathy (CL), and patients with cirrhosis with acute hepatic encephalopathy. Compared to HC subjects, blood flow and energy metabolism had......Hepatic encephalopathy is a condition of reduced brain functioning in which both blood flow and brain energy metabolism declined. It is not known whether blood flow or metabolism is the primary limiting factor of brain function in this condition. We used calculations of mitochondrial oxygen tension...

  12. Frequency of hepatitis B and hepatitis C in multi - transfused beta thalassemia major patients

    International Nuclear Information System (INIS)

    Iqbal, M.M.; Hassan, S.; Aziz, S.

    2010-01-01

    To determine the frequency of hepatitis B and C virus infection among children with beta thalassemia major registered at Military Hospital Rawalpindi. Children attending Thalassemia Centre Military Hospital Rawalpindi for regular blood transfusion were registered. They belonged to different ethnic groups and came from different parts of the country. Their demographic data was recorded, detailed history taken and physical examination was carried out. Their serum samples were tested for hepatitis B surface antigen and anti HCV antibody assay with third generation commercial ELISA method. During the study; 141 patients of beta thalassemia major were screened. Out of them 50 patients (35.5% ,95% confidence interval 27.8-43.5)w ere found hepatitis C virus antibody positive and 1 patient (0.7 %) hepatitis B surface antigen positive. One patient (0.7%) had both hepatitis B and C virus infection. Mean age of hepatitis C infected patients was 10.4+3.85y ears (range 2-16 years). Mean age of uninfected patients was 6.1 + 3.59 years. (p value 0.000) In addition, the results indicate that higher prevalence of anti-HCV was significantly associated with longer duration of transfusion (p value <0.003). In spite of the fact that screened blood is used for transfusions, still a large number of patients have been found infected with hepatitis C. Therefore more accurate techniques are required for screening of blood to prevent transfusion associated transmission. (author)

  13. Visualization of hypertrophied papillary muscle mimicking left ventricular mass on gated blood pool and T1-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Bunko, H.; Nakajima, K.; Tonami, N.; Asanoi, H.; Hisada, K.

    1981-01-01

    A sixty-year old man with acute myocardial infarction was incidentally found to have a hypertrophied anterolateral papillary muscle (ALPPM) of the left ventricle on gated blood pool (GBP) and T1-201 myocardial perfusion images. Hypertrophy of the ALPPM was visualized as a movable defect in the lateral basal area on GBP imaging throughout the cardiac cycle and on the TI-201 study as a radionuclide accumulating structure, consistent with the defect in the GBP. A combination of these findings may suggest the presence of a hypertrophied papillary muscle of the left ventricle

  14. Quantitative aspects of myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Vogel, R.A.

    1980-01-01

    Myocardial perfusion measurements have traditionally been performed in a quantitative fashion using application of the Sapirstein, Fick, Kety-Schmidt, or compartmental analysis principles. Although global myocardial blood flow measurements have not proven clinically useful, regional determinations have substantially advanced our understanding of and ability to detect myocardial ischemia. With the introduction of thallium-201, such studies have become widely available, although these have generally undergone qualitative evaluation. Using computer-digitized data, several methods for the quantification of myocardial perfusion images have been introduced. These include orthogonal and polar coordinate systems and anatomically oriented region of interest segmentation. Statistical ranges of normal and time-activity analyses have been applied to these data, resulting in objective and reproducible means of data evaluation

  15. Seroprevalence of hepatitis B e antigen (HBe antigen and B core antibodies (IgG anti-HBcore and IgM anti-HBcore among hepatitis B surface antigen positive blood donors at a Tertiary Centre in Nigeria

    Directory of Open Access Journals (Sweden)

    Akinbami Akinsegun A

    2012-03-01

    Full Text Available Abstract Background Hepatitis B virus (HBV is a common cause of liver disease throughout the world. HBV is transmitted through blood and other body fluids, including semen and saliva. Chronic replication of HBV virons is characterized by persistence circulation of HBsAg, HBeAg and HBV DNA; usually with anti-HBc and occasionally with anti-HBs. Aim: To determine the prevalence of HBeAg, IgG anti-HBcore and IgM anti-HBcore amongst HBsAg positive blood donors. These parameters are reflective of transmissibility and active hepatitis B infection. A cross sectional study was carried out at the blood donor clinics of Lagos State University Teaching Hospital Ikeja and Lagos University Teaching Hospital Idiaraba. A total of 267 donors were recruited to determine HBe antigen, IgG and IgM anti-HBcore antibodies amongst hepatitis BsAg positive donors. Five milliliters of blood was collected from those who tested positive to HBsAg screen during donation. The sera were subjected to enzyme linked immunosorbent assay (ELISA. Pearson chi-squared test was used for the analytical assessment. Findings A total number of 267 HBsAg positive blood donors were studied. A seroprevalence of 8.2% (22 of 267 HBeAg was obtained, 4 of 267 (1.5% were indeterminate while 241 (90.3% tested negative. Only 27 out of 267 donors (10.1% tested positive to IgM anti-HBcore, 234(87.6% tested negative, while 6(2.2% were indeterminate. A higher percentage of 60.7% (162 of 267 tested positive to IgG anti-HBcore, while 39.3% (105 of 267 tested negative. Conclusion There is a low seroprevalence rate of HBeAg-positive chronic hepatitis and relatively high IgG anti-HBcore and IgM anti-HBcore rates in South West Nigeria.

  16. Follow-up of pulmonary perfusion recovery after embolism

    International Nuclear Information System (INIS)

    Palla, A.; Donnamaria, V.; Petruzzelli, S.; Giuntini, C.

    1986-01-01

    Blood flow recovery in a group of 69 patients with pulmonary embolism was followed by serial lung scans over a six month period. Each patient underwent perfusion lung scan at diagnosis then 7, 30 and 180 days later; i.v. heparin was systematically administered for one week after diagnosis, followed by oral warfarin for six months. Blood flow impairment was evaluated by assessing the total number of unperfused lung segments (ULS), as calculated on both lateral views at each scan. The number of ULS was significantly reduced at each interval (P<0.001), ranging from 8.4±3.3 at diagnosis to 3.6±2.7 six months later; most of the recovery (79%) occurred within the first month. No patient had complete restoration of pulmonary blood flow during the whole follow-up period. No difference was found between the number of ULS in right lung versus that in left lung at each interval. Recovery of blood flow was heavily affected by coexisting cardiac or pulmonary disease. In fact, those patients with underlying cardiopulmonary disease (49.2% of the total) showed significantly smaller perfusion improvement after six months (P<0.001). Eight patients (6 with and 2 without cardiopulmonary disease) had clinical and scintigraphic evidence of recurrent embolism during the follow-up period

  17. Comparison of Regional Brain Perfusion Levels in Chronically Smoking and Non-Smoking Adults

    Directory of Open Access Journals (Sweden)

    Timothy C. Durazzo

    2015-07-01

    Full Text Available Chronic cigarette smoking is associated with numerous abnormalities in brain neurobiology, but few studies specifically investigated the chronic effects of smoking (compared to the acute effects of smoking, nicotine administration, or nicotine withdrawal on cerebral perfusion (i.e., blood flow. Predominately middle-aged male (47 ± 11 years of age smokers (n = 34 and non-smokers (n = 27 were compared on regional cortical perfusion measured by continuous arterial spin labeling magnetic resonance studies at 4 Tesla. Smokers showed significantly lower perfusion than non-smokers in the bilateral medial and lateral orbitofrontal cortices, bilateral inferior parietal lobules, bilateral superior temporal gyri, left posterior cingulate, right isthmus of cingulate, and right supramarginal gyrus. Greater lifetime duration of smoking (adjusted for age was related to lower perfusion in multiple brain regions. The results indicated smokers showed significant perfusion deficits in anterior cortical regions implicated in the development, progression, and maintenance of all addictive disorders. Smokers concurrently demonstrated reduced blood flow in posterior brain regions that show morphological and metabolic aberrations as well as elevated beta amyloid deposition demonstrated by those with early stage Alzheimer disease. The findings provide additional novel evidence of the adverse effects of cigarette smoking on the human brain.

  18. Perfusion-induced changes in cardiac contractility depend on capillary perfusion.

    Science.gov (United States)

    Dijkman, M A; Heslinga, J W; Sipkema, P; Westerhof, N

    1998-02-01

    The perfusion-induced increase in cardiac contractility (Gregg phenomenon) is especially found in heart preparations that lack adequate coronary autoregulation and thus protection of changes in capillary pressure. We determined in the isolated perfused papillary muscle of the rat whether cardiac muscle contractility is related to capillary perfusion. Oxygen availability of this muscle is independent of internal perfusion, and perfusion may be varied or even stopped without loss of function. Muscles contracted isometrically at 27 degrees C (n = 7). During the control state stepwise increases in perfusion pressure resulted in all muscles in a significant increase in active tension. Muscle diameter always increased with increased perfusion pressure, but muscle segment length was unaffected. Capillary perfusion was then obstructed by plastic microspheres (15 microns). Flow, at a perfusion pressure of 66.6 +/- 26.2 cmH2O, reduced from 17.6 +/- 5.4 microliters/min in the control state to 3.2 +/- 1.3 microliters/min after microspheres. Active tension developed by the muscle in the unperfused condition before microspheres and after microspheres did not differ significantly (-12.8 +/- 29.4% change). After microspheres similar perfusion pressure steps as in control never resulted in an increase in active tension. Even at the two highest perfusion pressures (89.1 +/- 28.4 and 106.5 +/- 31.7 cmH2O) that were applied a significant decrease in active tension was found. We conclude that the Gregg phenomenon is related to capillary perfusion.

  19. Nucleoside Analog-treated Chronic Hepatitis B Patients showed Reduced Expression of PECAM-1 Gene in Peripheral Blood Mononuclear Cells in Bangladesh

    Science.gov (United States)

    Tabassum, Shahina; Ullah Munshi, Saif; Hossain, Marufa; Imam, Akhter

    2014-01-01

    ABSTRACT Background and aim Assessment of therapeutic response is important for monitoring the prognosis and to take decision for cessation of nucleoside analogues therapy in chronic hepatitis B patients. In addition to serum alanine aminotransferase (ALT), hepatitis B virus (HBV) deoxyribonucleic acid (DNA) load and HBeAg status, identification of molecular markers associated with host immune response would be essential to assess therapeutic response. In this regard the current study was performed with the aim to detect expression of platelet endothelial cell adhesion molecule (PECAM)-I gene in peripheral blood monocytes (PBMCs) of treated chronic hepatitis B patients and also to correlate expression of this gene with serum HBV DNA load and serum ALT levels. Materials and methods The study analyzed 60 chronic hepatitis B (CHB) patients, including 30 untreated and 30 nucleoside analogs treated and 10 healthy controls. PECAM-1 gene expression/ transcripts were detected by conventional RT-PCR. Results The expression PECAM-1 mRNA in the PBMCs of CHB patients was significantly higher in untreated (3.17 ± 0.75) than the treated patients (1.64 ± 0.29) (p Tabassum S, Munshi SU, Hossain M, Imam A. Nucleoside Analog-treated Chronic Hepatitis B Patients showed Reduced Expression of PECAM-1 Gene in Peripheral Blood Mononuclear Cells in Bangladesh. Euroasian J Hepato-Gastroenterol 2014;4(2):87-91. PMID:29699354

  20. Spatial interaction between tissue pressure and skeletal muscle perfusion during contraction.

    Science.gov (United States)

    van Donkelaar, C C; Huyghe, J M; Vankan, W J; Drost, M R

    2001-05-01

    The vascular waterfall theory attributes decreased muscle perfusion during contraction to increased intramuscular pressure (P(IM)) and concomitant increase in venous resistance. Although P(IM) is distributed during contractions, this theory does not account for heterogeneity. This study hypothesises that pressure heterogeneity could affect the interaction between P(IM) rise and perfusion. Regional tissue perfusion during submaximum (100kPa) tetanic contraction is studied, using a finite element model of perfused contracting skeletal muscle. Capillary flow in muscles with one proximal artery and vein (SIM(1)) and with an additional distal artery and vein (SIM(2)) is compared. Blood flow and pressures at rest and P(IM) during contraction ( approximately 25kPa maximally) are similar between simulations, but capillary flow and venous pressure differ. In SIM(2), venous pressure and capillary flow correspond to P(IM) distribution, whereas capillary flow in SIM(1) is less than 10% of flow in SIM(2), in the muscle half without draining vein. This difference is caused by a high central P(IM), followed by central venous pressure rise, in agreement with the waterfall theory. The high central pressure (SIM(1)), obstructs outflow from the distal veins. Distal venous pressure rises until central blood pressure is reached, although local P(IM) is low. Adding a distal vein (SIM(2)) restores the perfusion. It is concluded that regional effects contribute to the interaction between P(IM) and perfusion during contraction. Unlike stated by the vascular waterfall theory, venous pressure may locally exceed P(IM). Although this can be explained by the principles of this theory, the theory does not include this phenomenon as such.